WorldWideScience

Sample records for upset rate calculations

  1. Calculation of cosmic ray induced single event upsets: Program CRUP (Cosmic Ray Upset Program)

    Science.gov (United States)

    Shapiro, P.

    1983-09-01

    This report documents PROGRAM CRUP, COSMIC RAY UPSET PROGRAM. The computer program calculates cosmic ray induced single-event error rates in microelectronic circuits exposed to several representative cosmic-ray environments.

  2. Proton upset rate prediction: a new sensitive volume concept definition

    International Nuclear Information System (INIS)

    Inguimbert, Christophe

    1999-01-01

    We present a model for predicting proton induced single event upset rate. The approach uses heavy ion cross section experimental data combined with nuclear reaction calculations in order to determine the proton upset cross section. The p+Si nuclear reaction as well as the Si(p, p)Si Coulombic scattering are described. The upset rate calculation depends on the energy deposited available in the charge collection region (sensitive region). This region is treated as a rectangular parallelepiped of thickness d at depth h. The sensitive thickness d is used as an input parameter in our model we have developed an original method to probe the sensitive region to evaluate d with reasonable accuracy d. We use short range ions and we propose a new mathematical analysis of these experimental data to determine h and d. This method consists in de-convoluting the heavy ion upset cross section σ_S_E_U(r) by the LET function of the incident ion LET(r) (r is the range of the incident ion). Our results are in relatively good agreement with other models. The accuracy of the method allows us to discuss the validity of the sensitive volume concept. Furthermore, we extrapolate an internal gain factor α that permit to take into account the charge collection mechanisms. α and d serve for quick and reasonably accurate prediction of proton induced SEU cross section in microelectronic devices. (author) [fr

  3. Calculation of neutron-induced single-event upset cross sections for semiconductor memory devices

    International Nuclear Information System (INIS)

    Ikeuchi, Taketo; Watanabe, Yukinobu; Nakashima, Hideki; Sun, Weili

    2001-01-01

    Neutron-induced single-event upset (SEU) cross sections for semiconductor memory devices are calculated by the Burst Generation Rate (BGR) method using LA150 data and QMD calculation in the neutron energy range between 20 MeV and 10 GeV. The calculated results are compared with the measured SEU cross sections for energies up to 160 MeV, and the validity of the calculation method and the nuclear data used is verified. The kind of reaction products and the neutron energy range that have the most effect on SEU are discussed. (author)

  4. Approaches to proton single-event rate calculations

    International Nuclear Information System (INIS)

    Petersen, E.L.

    1996-01-01

    This article discusses the fundamentals of proton-induced single-event upsets and of the various methods that have been developed to calculate upset rates. Two types of approaches are used based on nuclear-reaction analysis. Several aspects can be analyzed using analytic methods, but a complete description is not available. The paper presents an analytic description for the component due to elastic-scattering recoils. There have been a number of studies made using Monte Carlo methods. These can completely describe the reaction processes, including the effect of nuclear reactions occurring outside the device-sensitive volume. They have not included the elastic-scattering processes. The article describes the semiempirical approaches that are most widely used. The quality of previous upset predictions relative to space observations is discussed and leads to comments about the desired quality of future predictions. Brief sections treat the possible testing limitation due to total ionizing dose effects, the relationship of proton and heavy-ion upsets, upsets due to direct proton ionization, and relative proton and cosmic-ray upset rates

  5. The measurement and prediction of proton upset

    Science.gov (United States)

    Shimano, Y.; Goka, T.; Kuboyama, S.; Kawachi, K.; Kanai, T.

    1989-12-01

    The authors evaluate tolerance to proton upset for three kinds of memories and one microprocessor unit for space use by irradiating them with high-energy protons up to nearly 70 MeV. They predict the error rates of these memories using a modified semi-empirical equation of Bendel and Petersen (1983). A two-parameter method was used instead of Bendel's one-parameter method. There is a large difference between these two methods with regard to the fitted parameters. The calculation of upset rates in orbits were carried out using these parameters and NASA AP8MAC, AP8MIC. For the 93419 RAM the result of this calculation was compared with the in-orbit data taken on the MOS-1 spacecraft. A good agreement was found between the two sets of upset-rate data.

  6. Single event upsets calculated from new ENDF/B-VI proton and neutron data up to 150 MeV

    International Nuclear Information System (INIS)

    Chadwick, M.B.

    1999-01-01

    Single-event upsets (SEU) in microelectronics are calculated from newly-developed silicon nuclear reaction recoil data that extend up to 150 MeV, for incident protons and neutrons. Calculated SEU cross sections are compared with measured data

  7. Application of reactors for testing neutron-induced upsets in commercial SRAMs

    International Nuclear Information System (INIS)

    Griffin, P.J.; Luera, T.F.; Sexton, F.W.; Cooper, P.J.; Karr, S.G.; Hash, G.L.; Fuller, E.

    1997-01-01

    Reactor neutron environments can be used to test/screen the sensitivity of unhardened commercial SRAMs to low-LET neutron-induced upset. Tests indicate both thermal/epithermal (< 1 keV) and fast neutrons can cause upsets in unhardened parts. Measured upset rates in reactor environments can be used to model the upset rate for arbitrary neutron spectra

  8. Investigation of Single Events Upsets in Silicon and GaAs Structures Using Reaction Calculations

    Science.gov (United States)

    1994-09-01

    Cubed Corporation. The CREME (Cosmic-Ray-Effects on Microelectronics) (73) and the CRUP (Cos- mic Ray Upset Program) (74) are both from the Naval...knowledge, that is impossible to do in advance. The errors per bit day calculated using CREME and CRUP for a device exposed to Adams’ 90% worst-case...emitter junction was measured for alpha particles ion measurements and used in CREME (2) and CRUP from an Americium source in two ways: First, the (3

  9. Talys calculations for evaluation of neutron-induced single-event upset cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Bourselier, Jean-Christophe

    2005-08-15

    The computer code TALYS has been used to calculate interactions between cosmic-ray neutrons and silicon nuclei with the goal to describe single-event upset (SEU) cross sections in microelectronics devices. Calculations for the Si(n,X) reaction extend over an energy range of 2 to 200 MeV. The obtained energy spectra of the resulting residuals and light-ions have been integrated using several different critical charges as SEU threshold. It is found that the SEU cross section seems largely to be dominated by {sup 28}Si recoils from elastic scattering. Furthermore, the shape of the SEU cross section as a function of the energy of the incoming neutron changes drastically with decreasing critical charge. The results presented in this report stress the importance of performing studies at mono-energetic neutron beams to advance the understanding of the underlying mechanisms causing SEUs.

  10. Talys calculations for evaluation of neutron-induced single-event upset cross sections

    International Nuclear Information System (INIS)

    Bourselier, Jean-Christophe

    2005-08-01

    The computer code TALYS has been used to calculate interactions between cosmic-ray neutrons and silicon nuclei with the goal to describe single-event upset (SEU) cross sections in microelectronics devices. Calculations for the Si(n,X) reaction extend over an energy range of 2 to 200 MeV. The obtained energy spectra of the resulting residuals and light-ions have been integrated using several different critical charges as SEU threshold. It is found that the SEU cross section seems largely to be dominated by 28 Si recoils from elastic scattering. Furthermore, the shape of the SEU cross section as a function of the energy of the incoming neutron changes drastically with decreasing critical charge. The results presented in this report stress the importance of performing studies at mono-energetic neutron beams to advance the understanding of the underlying mechanisms causing SEUs

  11. Airplane Upset Training Evaluation Report

    Science.gov (United States)

    Gawron, Valerie J.; Jones, Patricia M. (Technical Monitor)

    2002-01-01

    Airplane upset accidents are a leading factor in hull losses and fatalities. This study compared five types of airplane-upset training. Each group was composed of eight, non-military pilots flying in their probationary year for airlines operating in the United States. The first group, 'No aero / no upset,' was made up of pilots without any airplane upset training or aerobatic flight experience; the second group, 'Aero/no upset,' of pilots without any airplane-upset training but with aerobatic experience; the third group, 'No aero/upset,' of pilots who had received airplane-upset training in both ground school and in the simulator; the fourth group, 'Aero/upset,' received the same training as Group Three but in addition had aerobatic flight experience; and the fifth group, 'In-flight' received in-flight airplane upset training using an instrumented in-flight simulator. Recovery performance indicated that clearly training works - specifically, all 40 pilots recovered from the windshear upset. However few pilots were trained or understood the use of bank to change the direction of the lift vector to recover from nose high upsets. Further, very few thought of, or used differential thrust to recover from rudder or aileron induced roll upsets. In addition, recovery from icing-induced stalls was inadequate.

  12. Single event upsets correlated with environment

    International Nuclear Information System (INIS)

    Vampola, A.L.; Albin, F.; Lauriente, M.; Wilkinson, D.C.; Allen, J.

    1994-01-01

    Single Event Upset rates on satellites in different Earth orbits are correlated with solar protons and geomagnetic activity and also with the NASA AP8 proton model to extract information about satellite anomalies caused by the space environment. An extensive discussion of the SEU data base from the TOMS solid state recorder and an algorithm for correcting spontaneous upsets in it are included as an Appendix. SAMPEX and TOMS, which have the same memory chips, have similar normalized responses in the South Atlantic Anomaly. SEU rates due to solar protons over the polar caps are within expectations. No geomagnetic activity effects can be discerned in the SEU rates

  13. Heavy Ion Irradiation Fluence Dependence for Single-Event Upsets in a NAND Flash Memory

    Science.gov (United States)

    Chen, Dakai; Wilcox, Edward; Ladbury, Raymond L.; Kim, Hak; Phan, Anthony; Seidleck, Christina; Label, Kenneth

    2016-01-01

    We investigated the single-event effect (SEE) susceptibility of the Micron 16 nm NAND flash, and found that the single-event upset (SEU) cross section varied inversely with cumulative fluence. We attribute the effect to the variable upset sensitivities of the memory cells. Furthermore, the effect impacts only single cell upsets in general. The rate of multiple-bit upsets remained relatively constant with fluence. The current test standards and procedures assume that SEU follow a Poisson process and do not take into account the variability in the error rate with fluence. Therefore, traditional SEE testing techniques may underestimate the on-orbit event rate for a device with variable upset sensitivity.

  14. Experimental Research and Method for Calculation of 'Upsetting-with-Buckling' Load at the Impression-Free (Dieless Preforming of Workpiece

    Directory of Open Access Journals (Sweden)

    Kukhar Volodymir

    2018-01-01

    Full Text Available This paper presents the results of experimental studies of load characteristic changes during the upsetting of high billets with the upsetting ratio (height to diameter ratio from 3.0 to 6.0, which is followed by buckling. Such pass is an effective way of preforming the workpiece for production of forgings with a bended axis or dual forming, and belongs to impression-free (dieless operation of bulk forming. Based on the experimental data analysis, an engineering method for calculation of workpiece pre-forming load as a maximum buckling force has been developed. The analysis of the obtained data confirmed the possibility of performing of this pre-forming operation on the main forging equipment, since the load of shaping by buckling does not exceed the load of the dieforging.

  15. Experimental Research and Method for Calculation of 'Upsetting-with-Buckling' Load at the Impression-Free (Dieless) Preforming of Workpiece

    Science.gov (United States)

    Kukhar, Volodymir; Artiukh, Victor; Prysiazhnyi, Andrii; Pustovgar, Andrey

    2018-03-01

    This paper presents the results of experimental studies of load characteristic changes during the upsetting of high billets with the upsetting ratio (height to diameter ratio) from 3.0 to 6.0, which is followed by buckling. Such pass is an effective way of preforming the workpiece for production of forgings with a bended axis or dual forming, and belongs to impression-free (dieless) operation of bulk forming. Based on the experimental data analysis, an engineering method for calculation of workpiece pre-forming load as a maximum buckling force has been developed. The analysis of the obtained data confirmed the possibility of performing of this pre-forming operation on the main forging equipment, since the load of shaping by buckling does not exceed the load of the dieforging.

  16. Monte Carlo calculation of the cross-section of single event upset induced by 14MeV neutrons

    International Nuclear Information System (INIS)

    Li, H.; Deng, J.Y.; Chang, D.M.

    2005-01-01

    High-density static random access memory may experience single event upsets (SEU) in neutron environments. We present a new method to calculate the SEU cross-section. Our method is based on explicit generation and transport of the secondary reaction products and detailed accounting for energy loss by ionization. Instead of simulating the behavior of the circuit, we use the Monte Carlo method to simulate the process of energy deposition in sensitive volumes. Thus, we do not need to know details about the circuit. We only need a reasonable guess for the size of the sensitive volumes. In the Monte Carlo simulation, the cross-section of SEU induced by 14MeV neutrons is calculated. We can see that the Monte Carlo simulation not only can provide a new method to calculate SEU cross-section, but also can give a detailed description about random process of the SEU

  17. Heavy Ion Irradiation Fluence Dependence for Single-Event Upsets of NAND Flash Memory

    Science.gov (United States)

    Chen, Dakai; Wilcox, Edward; Ladbury, Raymond; Kim, Hak; Phan, Anthony; Seidleck, Christina; LaBel, Kenneth

    2016-01-01

    We investigated the single-event effect (SEE) susceptibility of the Micron 16 nm NAND flash, and found the single-event upset (SEU) cross section varied inversely with fluence. The SEU cross section decreased with increasing fluence. We attribute the effect to the variable upset sensitivities of the memory cells. The current test standards and procedures assume that SEU follow a Poisson process and do not take into account the variability in the error rate with fluence. Therefore, heavy ion irradiation of devices with variable upset sensitivity distribution using typical fluence levels may underestimate the cross section and on-orbit event rate.

  18. Dynamic effect in ultrasonic assisted micro-upsetting

    Science.gov (United States)

    Presz, Wojciech

    2018-05-01

    The use of ultrasonic assistance in microforming is becoming more and more popular. Mainly due to the beneficial effect of vibrations on the flow of plastic deformation reported already in the 50s of the last century. The influence is of two types: surface and volume. The surface effect is mainly the reduction of friction forces, and volumetric is the impact on the dislocation movement and even on phase transitions. The work focuses on the dynamic aspect of vibration assisted microforming. The use of ultrasonic vibrations at a frequency of 20 kHz and an amplitude of 16 µm, in the micro-upsetting process of an aluminum sample resulted in a high concentration of strain on both ends of the sample - at 14% of the height on both sides. There was observed (in relation to deformations of the sample without vibrations) 150-250% increase and a 50% decrease in strain in the center of the sample. At the same time, the larger deformations occurred from the impact side of the punch. Analyzing the course of forces of the upsetting process in the loading and unloading phase as well as the process of breaking glass samples, the spring deflections of key system elements and their natural frequencies were determined or calculated. Based on the determined or calculated parameters of the test stand, it was shown that during the micro-upsetting process the punch may detach from the sample surface and this is the main reason for the phenomena occurring. Detach of the punch is also the cause of the observed instability of the measurement of force, which should be considered unbelievable in such a situation.

  19. SUPRA - Enhanced upset recovery simulation

    NARCIS (Netherlands)

    Groen, E.; Ledegang, W.; Field, J.; Smaili, H.; Roza, M.; Fucke, L.; Nooij, S.; Goman, M.; Mayrhofer, M.; Zaichik, L.E.; Grigoryev, M.; Biryukov, V.

    2012-01-01

    The SUPRA research project - Simulation of Upset Recovery in Aviation - has been funded by the European Union 7th Framework Program to enhance the flight simulation envelope for upset recovery simulation. Within the project an extended aerodynamic model, capturing the key aerodynamics during and

  20. Single Event Upset Rate Estimates for a 16-K CMOS (Complementary Metal Oxide Semiconductor) SRAM (Static Random Access Memory).

    Science.gov (United States)

    1986-09-30

    4 . ~**..ft.. ft . - - - ft SI TABLES 9 I. SA32~40 Single Event Upset Test, 1140-MeV Krypton, 9/l8/8~4. . .. .. .. .. .. .16 II. CRUP Simulation...cosmic ray interaction analysis described in the remainder of this report were calculated using the CRUP computer code 3 modified for funneling. The... CRUP code requires, as inputs, the size of a depletion region specified as a retangular parallel piped with dimensions a 9 b S c, the effective funnel

  1. Relationship between single-event upset immunity and fabrication processes of recent memories

    International Nuclear Information System (INIS)

    Nemoto, N.; Shindou, H.; Kuboyama, S.; Matsuda, S.; Itoh, H.; Okada, S.; Nashiyama, I.

    1999-01-01

    Single-Event upset (SEU) immunity for commercial devices were evaluated by irradiation tests using high-energy heavy ions. We show test results and describe the relationship between observed SEU and structures/fabrication processes. We have evaluated single-even upset (SEU) tolerance of recent commercial memory devices using high energy heavy ions in order to find relationship between SEU rate and their fabrication process. It was revealed that the change of the process parameter gives much effect for the SEU rate of the devices. (authors)

  2. A capacitively coupled dose-rate-dependent transient upset mechanism in a bipolar memory

    International Nuclear Information System (INIS)

    Turfler, R.M.; Pease, R.L.; Dinger, G.; Armstrong, B.

    1992-01-01

    This paper reports on a pattern sensitivity that was observed in the threshold dose rate response of a bipolar 16K PROM for radiation pulse widths of 20-100 ns. For the worst case pattern, the upset threshold was a factor of three lower than for the commonly used checkerboard pattern. The mechanism for this pattern sensitivity was found to be a capacitively coupled voltage transient on a sensitive node which caused a low-to-high transition at the output. A design fix was implemented to significantly alter the ratio of the two parasitic capacitances in a capacitive divider which reduced the amplitude of the voltage transient at the sensitive node. It was demonstrated that in the redesign, the pattern sensitivity was eliminated

  3. Neutron-induced single event upsets in static RAMS observed at 10 km flight altitude

    International Nuclear Information System (INIS)

    Olsen, J.; Becher, P.E.; Fynbo, P.B.; Raaby, P. Schultz, J.

    1993-01-01

    Neutron induced single event upsets (SEUs) in static memory devices (SRAMs) have so far been seen only in laboratory environments. The authors report observations of 14 neutron induced SEUs at commercial aircraft flight altitudes as well. The observed SEU rate at 10 km flight altitude based on exposure of 160 standard 256 Kbit CMOS SRAMs is 4.8 · 10 -8 upsets/bit/day. In the laboratory 117 SRAMs of two different brands were irradiated with fast neutrons from a Pu-Be source. A total of 176 SEUs have been observed, among these are two SEU pairs. The upset rates from the laboratory tests are compared to those found in the airborne SRAMS

  4. Impact of NBTI Aging on the Single-Event Upset of SRAM Cells

    CERN Document Server

    Bagatin, M; Gerardin, Simone; Paccagnella, Alessandro; Bagatin, Marta

    2010-01-01

    We analyzed the impact of negative bias temperature instability (NBTI) on the single-event upset rate of SRAM cells through experiments and SPICE simulations. We performed critical charge simulations introducing different degradation patterns in the cells, in three technology nodes, from 180 to 90 nm. The simulations results were checked with alpha-particle and heavy-ion irradiations on a 130-nm technology. Both simulations and experimental results show that NBTI degradation does not significantly affect the single-event upset SRAM cell rate as long as the parametric drift induced by aging is within 10\\%.

  5. Single event upsets in semiconductor devices induced by highly ionising particles.

    Science.gov (United States)

    Sannikov, A V

    2004-01-01

    A new model of single event upsets (SEUs), created in memory cells by heavy ions and high energy hadrons, has been developed. The model takes into account the spatial distribution of charge collection efficiency over the cell area not considered in previous approaches. Three-dimensional calculations made by the HADRON code have shown good agreement with experimental data for the energy dependence of proton SEU cross sections, sensitive depths and other SEU observables. The model is promising for prediction of SEU rates for memory chips exposed in space and in high-energy experiments as well as for the development of a high-energy neutron dosemeter based on the SEU effect.

  6. Test CMOS/SOS RAM for transient radiation upset comparative research and failure analysis

    International Nuclear Information System (INIS)

    Nikiforov, A.Y.; Poljakov, I.V.

    1995-01-01

    The test Complementary Metal-Oxide-Semiconductor/Silicon-on-Sapphire Random Access Memory (CMOS/SOS RAM) with eight types of memory cells was designed and tested at high dose rates with a flash X-ray machine and laser simulator. The memory cell (MC) design with additional transistors and RC-chain was found to be upset free up to 2 x 10 12 rad(Si)/s. An inversion effect was discovered in which almost 100% logic upset was observed in poorly protected memory cell arrays at very high dose rates

  7. Corrected multiple upsets and bit reversals for improved 1-s resolution measurements

    International Nuclear Information System (INIS)

    Brucker, G.J.; Stassinopoulos, E.G.; Stauffer, C.A.

    1994-01-01

    Previous work has studied the generation of single and multiple errors in control and irradiated static RAM samples (Harris 6504RH) which were exposed to heavy ions for relatively long intervals of time (minute), and read out only after the beam was shut off. The present investigation involved storing 4k x 1 bit maps every second during 1 min ion exposures at low flux rates of 10 3 ions/cm 2 -s in order to reduce the chance of two sequential ions upsetting adjacent bits. The data were analyzed for the presence of adjacent upset bit locations in the physical memory plane, which were previously defined to constitute multiple upsets. Improvement in the time resolution of these measurements has provided more accurate estimates of multiple upsets. The results indicate that the percentage of multiples decreased from a high of 17% in the previous experiment to less than 1% for this new experimental technique. Consecutive double and triple upsets (reversals of bits) were detected. These were caused by sequential ions hitting the same bit, with one or two reversals of state occurring in a 1-min run. In addition to these results, a status review for these same parts covering 3.5 years of imprint damage recovery is also presented

  8. Single event upset test programs

    International Nuclear Information System (INIS)

    Russen, L.C.

    1984-11-01

    It has been shown that the heavy ions in cosmic rays can give rise to single event upsets in VLSI random access memory devices (RAMs). Details are given of the programs written to test 1K, 4K, 16K and 64K memories during their irradiation with heavy charged ions, in order to simulate the effects of cosmic rays in space. The test equipment, which is used to load the memory device to be tested with a known bit pattern, and subsequently interrogate it for upsets, or ''flips'', is fully described. (author)

  9. Upset in response to a Sibling's partner's infidelities.

    Science.gov (United States)

    Michalski, Richard L; Shackelford, Todd K; Salmon, Catherine A

    2007-03-01

    Using data collected from people with at least one brother and one sister, and consistent with an evolutionary perspective, we find that older men and women (a) are more upset by a brother's partner's sexual infidelity than by her emotional infidelity and (b) are more upset by a sister's partner's emotional infidelity than by his sexual infidelity. There were no effects of participant sex or sex of in-law on upset over a sibling's partner's infidelities, but there was an effect of participant sex on reports of upset over one's own partner's infidelities. The results suggest that the key variable among older participants is the sex of the sibling or, correspondingly, the sex of the sibling's partner, as predicted from an evolutionary analysis of reproductive costs, and not the sex of the participant, as predicted from a socialization perspective. Discussion offers directions for future work on jealousy.

  10. Heavy ion and proton-induced single event multiple upset

    International Nuclear Information System (INIS)

    Reed, R.A.; Carts, M.A.; Marshall, P.W.

    1997-01-01

    Individual ionizing heavy ion events are shown to cause two or more adjacent memory cells to change logic states in a high density CMOS SRAM. A majority of the upsets produced by normally incident heavy ions are due to single-particle events that causes a single cell to upset. However, for grazing angles a majority of the upsets produced by heavy-ion irradiation are due to single-particle events that cause two or more cells to change logic states. Experimental evidence of a single proton-induced spallation reaction that causes two adjacent memory cells to change logic states is presented. Results from a dual volume Monte-Carlo simulation code for proton-induced single-event multiple upsets are within a factor of three of experimental data for protons at normal incidence and 70 degrees

  11. UpSet: Visualization of Intersecting Sets

    Science.gov (United States)

    Lex, Alexander; Gehlenborg, Nils; Strobelt, Hendrik; Vuillemot, Romain; Pfister, Hanspeter

    2016-01-01

    Understanding relationships between sets is an important analysis task that has received widespread attention in the visualization community. The major challenge in this context is the combinatorial explosion of the number of set intersections if the number of sets exceeds a trivial threshold. In this paper we introduce UpSet, a novel visualization technique for the quantitative analysis of sets, their intersections, and aggregates of intersections. UpSet is focused on creating task-driven aggregates, communicating the size and properties of aggregates and intersections, and a duality between the visualization of the elements in a dataset and their set membership. UpSet visualizes set intersections in a matrix layout and introduces aggregates based on groupings and queries. The matrix layout enables the effective representation of associated data, such as the number of elements in the aggregates and intersections, as well as additional summary statistics derived from subset or element attributes. Sorting according to various measures enables a task-driven analysis of relevant intersections and aggregates. The elements represented in the sets and their associated attributes are visualized in a separate view. Queries based on containment in specific intersections, aggregates or driven by attribute filters are propagated between both views. We also introduce several advanced visual encodings and interaction methods to overcome the problems of varying scales and to address scalability. UpSet is web-based and open source. We demonstrate its general utility in multiple use cases from various domains. PMID:26356912

  12. Analyzing System on A Chip Single Event Upset Responses using Single Event Upset Data, Classical Reliability Models, and Space Environment Data

    Science.gov (United States)

    Berg, Melanie; LaBel, Kenneth; Campola, Michael; Xapsos, Michael

    2017-01-01

    We are investigating the application of classical reliability performance metrics combined with standard single event upset (SEU) analysis data. We expect to relate SEU behavior to system performance requirements. Our proposed methodology will provide better prediction of SEU responses in harsh radiation environments with confidence metrics. single event upset (SEU), single event effect (SEE), field programmable gate array devises (FPGAs)

  13. Review of Research On Guidance for Recovery from Pitch Axis Upsets

    Science.gov (United States)

    Harrison, Stephanie J.

    2016-01-01

    A literature review was conducted to identify past efforts in providing control guidance for aircraft upset recovery including stall recovery. Because guidance is integrally linked to the intended function of aircraft attitude awareness and upset recognition, it is difficult, if not impossible, to consider these issues separately. This literature review covered the aspects of instrumentation and display symbologies for attitude awareness, aircraft upset recognition, upset and stall alerting, and control guidance. Many different forms of symbology have been investigated including, but not limited to, pitch scale depictions, attitude indicator icons, horizon symbology, attitude recovery arrows, and pitch trim indicators. Past research on different visual and alerting strategies that provide advisories, cautions, and warnings to pilots before entering an unusual attitude (UA) are also discussed. Finally, potential control guidance for recovery from upset or unusual attitudes, including approach-to-stall and stall conditions, are reviewed. Recommendations for future research are made.

  14. Single-word multiple-bit upsets in static random access devices

    International Nuclear Information System (INIS)

    Koga, R.; Pinkerton, S.D.; Lie, T.J.; Crawford, K.B.

    1993-01-01

    Energetic ions and protons can cause single event upsets (SEUs) in static random access memory (SRAM) cells. In some cases multiple bits may be upset as the result of a single event. Space-borne electronics systems incorporating high-density SRAM are vulnerable to single-word multiple-bit upsets (SMUs). The authors review here recent observations of SMU, present the results of a systematic investigation of the physical cell arrangements employed in several currently available SRAM device types, and discuss implications for the occurrence and mitigation of SMU

  15. Upset Prediction in Friction Welding Using Radial Basis Function Neural Network

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2013-01-01

    Full Text Available This paper addresses the upset prediction problem of friction welded joints. Based on finite element simulations of inertia friction welding (IFW, a radial basis function (RBF neural network was developed initially to predict the final upset for a number of welding parameters. The predicted joint upset by the RBF neural network was compared to validated finite element simulations, producing an error of less than 8.16% which is reasonable. Furthermore, the effects of initial rotational speed and axial pressure on the upset were investigated in relation to energy conversion with the RBF neural network. The developed RBF neural network was also applied to linear friction welding (LFW and continuous drive friction welding (CDFW. The correlation coefficients of RBF prediction for LFW and CDFW were 0.963 and 0.998, respectively, which further suggest that an RBF neural network is an effective method for upset prediction of friction welded joints.

  16. Measuring Single Event Upsets in the ATLAS Inner Tracker

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    When the HL-LHC starts collecting data, the electronics inside will be subject to massive amounts of radiation. As a result, single event upsets could pose a threat to the ATLAS readout chain. The ABC130, a prototype front-end ASIC for the ATLAS inner tracker, must be tested for its susceptibility to single event upsets.

  17. TDRS-1 single event upsets and the effect of the space environment

    International Nuclear Information System (INIS)

    Wilkinson, D.C.; Daughtridge, S.C.; Stone, J.L.; Sauer, H.H.; Darling, P.

    1991-01-01

    The systematic recording of Single Event Upsets on TDRS-1 from 1984 to 1990 allows correlations to be drawn between those upsets and the space environment. In this paper, ground based neutron monitor data are used to illustrate the long-term relationship between galactic cosmic rays and TDRS-1 upsets. The short-term effects of energetic solar particles are illustrated with space environment data from GOES-7

  18. Proton induced single event upset cross section prediction for 0.15 μm six-transistor (6T) silicon-on-insulator static random access memories

    International Nuclear Information System (INIS)

    Li Lei; Zhou Wanting; Liu Huihua

    2012-01-01

    In this paper, an efficient physics-based method to estimate the saturated proton upset cross section for six-transistor (6T) silicon-on-insulator (SOI) static random access memory (SRAM) cells using layout and technology parameters is proposed. This method calculates the effects of radiation based on device physics. The simple method handles the problem with ease by SPICE simulations, which can be divided into two stages. At first, it uses a standard SPICE program to predict the cross section for recoiling heavy ions with linear energy transfer (LET) of 14 MeV-cm 2 /mg. Then, the predicted cross section for recoiling heavy ions with LET of 14 MeV-cm 2 /mg is used to estimate the saturated proton upset cross section for 6T SOI SRAM cells with a simple model. The calculated proton induced upset cross section based on this method is in good agreement with the test results of 6T SOI SRAM cells processed using 0.15 μm technology. (author)

  19. Dynamics Modeling and Simulation of Large Transport Airplanes in Upset Conditions

    Science.gov (United States)

    Foster, John V.; Cunningham, Kevin; Fremaux, Charles M.; Shah, Gautam H.; Stewart, Eric C.; Rivers, Robert A.; Wilborn, James E.; Gato, William

    2005-01-01

    As part of NASA's Aviation Safety and Security Program, research has been in progress to develop aerodynamic modeling methods for simulations that accurately predict the flight dynamics characteristics of large transport airplanes in upset conditions. The motivation for this research stems from the recognition that simulation is a vital tool for addressing loss-of-control accidents, including applications to pilot training, accident reconstruction, and advanced control system analysis. The ultimate goal of this effort is to contribute to the reduction of the fatal accident rate due to loss-of-control. Research activities have involved accident analyses, wind tunnel testing, and piloted simulation. Results have shown that significant improvements in simulation fidelity for upset conditions, compared to current training simulations, can be achieved using state-of-the-art wind tunnel testing and aerodynamic modeling methods. This paper provides a summary of research completed to date and includes discussion on key technical results, lessons learned, and future research needs.

  20. Single Event Upset Studies Using the ATLAS SCT

    CERN Document Server

    Dafinca, A; The ATLAS collaboration; Weidberg, A R

    2014-01-01

    Single Event Upsets (SEU) are expected to occur during high luminosity running of the ATLAS SemiConductor Tracker (SCT). The SEU cross sections were measured in pion beams with momenta in the range 200 to 465 MeV/c and proton test beams at 24 GeV/c but the extrapolation to LHC conditions is non-trivial because of the range of particle types and momenta. The SEUs studied occur in the p-i-n photodiode and the registers in the ABCD chip. Comparisons between predicted SEU rates and those measured from ATLAS data are presented. The implications for ATLAS operation are discussed

  1. Modeling and control of a DC upset resistance butt welding process

    NARCIS (Netherlands)

    Naus, G.J.L.; Meulenberg, R.; Molengraft, van de M.J.G.

    2007-01-01

    This paper presents the analysis and synthesis of modeling and control of the DC upset resistance butt welding process used in rim production lines. A new control strategy is developed, enabling active control of the welding seam temperature and the upset size. As a result, set-up times and energy

  2. Reactor internals design/analysis for normal, upset, and faulted conditions

    International Nuclear Information System (INIS)

    Burke, F.R.

    1977-06-01

    The analytical procedures used by Babcock and Wilcox to demonstrate the structural integrity of the 205-FA reactor internals are described. Analytical results are presented and compared to ASME Code allowable limits for Normal, Upset, and Faulted conditions. The particular faulted condition considered is a simultaneous loss-of-coolant accident and safe shutdown earthquake. The operating basis earthquake is addressed as an Upset condition

  3. Upset Over Sexual versus Emotional Infidelity Among Gay, Lesbian, Bisexual, and Heterosexual Adults.

    Science.gov (United States)

    Frederick, David A; Fales, Melissa R

    2016-01-01

    One hypothesis derived from evolutionary perspectives is that men are more upset than women by sexual infidelity and women are more upset than men by emotional infidelity. The proposed explanation is that men, in contrast to women, face the risk of unwittingly investing in genetically unrelated offspring. Most studies, however, have relied on small college or community samples of heterosexual participants. We examined upset over sexual versus emotional jealousy among 63,894 gay, lesbian, bisexual, and heterosexual participants. Participants imagined which would upset them more: their partners having sex with someone else (but not falling in love with them) or their partners falling in love with someone else (but not having sex with them). Consistent with this evolutionary perspective, heterosexual men were more likely than heterosexual women to be upset by sexual infidelity (54 vs. 35 %) and less likely than heterosexual women to be upset by emotional infidelity (46 vs. 65 %). This gender difference emerged across age groups, income levels, history of being cheated on, history of being unfaithful, relationship type, and length. The gender difference, however, was limited to heterosexual participants. Bisexual men and women did not differ significantly from each other in upset over sexual infidelity (30 vs. 27 %), regardless of whether they were currently dating a man (35 vs. 29 %) or woman (28 vs. 20 %). Gay men and lesbian women also did not differ (32 vs. 34 %). The findings present strong evidence that a gender difference exists in a broad sample of U.S. adults, but only among heterosexuals.

  4. Single Event Upset Studies Using the ATLAS SCT

    CERN Document Server

    Weidberg, A R; The ATLAS collaboration

    2013-01-01

    Single Event Upsets (SEU) are expected to occur during high luminosity running of the ATLAS SemiConductor Tracker (SCT). The SEU cross sections were measured in pion beams with momenta in the range 200 to 465 MeV/c and proton test beams at 24 GeV/c but the extrapolation to LHC conditions is non-trivial because of the range of particle types and momenta. The SEUs studied occur in the \\emph{p-i-n} photodiode and the registers in the ABCD chip. Comparisons between predicted SEU rates and those measured from ATLAS data are presented. The implications for ATLAS operation are discussed.

  5. Single Event Upsets in the ATLAS IBL Front End ASICs

    CERN Document Server

    Rozanov, Alexandre; The ATLAS collaboration

    2018-01-01

    During operation at instantaneous luminosities of up to 2.1 1034 cm2 s−1 frontend chips of the ATLAS innermost pixel layer (IBL) experienced single event upsets affecting its global registers as well as the settings for the individual pixels, causing, amongst other things loss of occupancy, noisy pixels, and silent pixels. A quantitative analysis of the single event upsets as well as the operational issues and mitigation techniques are presented.

  6. Single Event Upsets in the ATLAS IBL Front End ASICs

    CERN Document Server

    Rozanov, Alexander; The ATLAS collaboration

    2018-01-01

    During operation at instantaneous luminosities of up to 2.1 10^{34} cm^{-2} s^{-1} the front end chips of the ATLAS innermost pixel layer (IBL) experienced single event upsets affecting its global registers as well as the settings for the individual pixels, causing, among other things loss of occupancy, noisy pixels, and silent pixels. A quantitative analysis of the single event upsets as well as the operational issues and mitigation techniques will be presented.

  7. Upset in Response to a Sibling’s Partner’s Infidelity

    OpenAIRE

    Dafni Hellstrand; Elisavet Chrysochoou

    2015-01-01

    Existing evidence suggests that the psychological design of romantic jealousy differs for men and women: Men are more likely than women to report greater upset in response to a partner’s sexual than emotional infidelity, whereas women are more likely than men to report greater upset in response to a partner’s emotional than sexual infidelity. However, the observed sex difference can be explained after the fact by both an evolutionary analysis of past reproductive costs and a social constructi...

  8. Fabrication and properties of Y-Ba-Cu-O high Tc superconductor by upset-forging method

    International Nuclear Information System (INIS)

    Chang, Ho Jung; Kang, Kae Myung; Song, Jin Tae

    1990-01-01

    YBa 2 Cu 3 O 7-x oxide superconductors was fabricated by sintering process and upset-forging method, respectively, and microstructures and conduction properties were compared. There was no difference in crystal structure the (001) x-ray reflection presumably due to preferred crystal orientation of the YBa 2 Cu 3 O 7-x superconductor. Furthermore, the grain size of the 123-phase increased as the reduction ratio became larger during the upset-forging. The critical temperature for zero resistivity of both samples was almost the same, i.e., about 90K. These results have demonstrated the potential of producing YBa 2 Cu 3 O 7-x superconducting wire or tape effectively using a upset-forging method. The critical current density of the upset-forged sample, however, was lower than that of the sintered one, which fact might be ascribed to microcrack formation during fast upset-forging. (Author)

  9. Single event upset susceptibilities of latchup immune CMOS process programmable gate arrays

    Science.gov (United States)

    Koga, R.; Crain, W. R.; Crawford, K. B.; Hansel, S. J.; Lau, D. D.; Tsubota, T. K.

    Single event upsets (SEU) and latchup susceptibilities of complementary metal oxide semiconductor programmable gate arrays (CMOS PPGA's) were measured at the Lawrence Berkeley Laboratory 88-in. cyclotron facility with Xe (603 MeV), Cu (290 MeV), and Ar (180 MeV) ion beams. The PPGA devices tested were those which may be used in space. Most of the SEU measurements were taken with a newly constructed tester called the Bus Access Storage and Comparison System (BASACS) operating via a Macintosh II computer. When BASACS finds that an output does not match a prerecorded pattern, the state of all outputs, position in the test cycle, and other necessary information is transmitted and stored in the Macintosh. The upset rate was kept between 1 and 3 per second. After a sufficient number of errors are stored, the test is stopped and the total fluence of particles and total errors are recorded. The device power supply current was closely monitored to check for occurrence of latchup. Results of the tests are presented, indicating that some of the PPGA's are good candidates for selected space applications.

  10. Analysis of Control Strategies for Aircraft Flight Upset Recovery

    Science.gov (United States)

    Crespo, Luis G.; Kenny, Sean P.; Cox, David E.; Muri, Daniel G.

    2012-01-01

    This paper proposes a framework for studying the ability of a control strategy, consisting of a control law and a command law, to recover an aircraft from ight conditions that may extend beyond the normal ight envelope. This study was carried out (i) by evaluating time responses of particular ight upsets, (ii) by evaluating local stability over an equilibrium manifold that included stall, and (iii) by bounding the set in the state space from where the vehicle can be safely own to wings-level ight. These states comprise what will be called the safely recoverable ight envelope (SRFE), which is a set containing the aircraft states from where a control strategy can safely stabilize the aircraft. By safe recovery it is implied that the tran- sient response stays between prescribed limits before converging to a steady horizontal ight. The calculation of the SRFE bounds yields the worst-case initial state corresponding to each control strategy. This information is used to compare alternative recovery strategies, determine their strengths and limitations, and identify the most e ective strategy. In regard to the control law, the authors developed feedback feedforward laws based on the gain scheduling of multivariable controllers. In regard to the command law, which is the mechanism governing the exogenous signals driving the feed- forward component of the controller, we developed laws with a feedback structure that combines local stability and transient response considera- tions. The upset recovery of the Generic Transport Model, a sub-scale twin-engine jet vehicle developed by NASA Langley Research Center, is used as a case study.

  11. Relationship between single-event upset immunity and fabrication processes of recent memories; Relations entre l'immunite au SEU et les procedes de fabrication de memoires recentes

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, N.; Shindou, H.; Kuboyama, S.; Matsuda, S. [National Space Development Agency of Japan, Ibaraki-ken (Japan); Itoh, H.; Okada, S.; Nashiyama, I. [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan)

    1999-07-01

    Single-Event upset (SEU) immunity for commercial devices were evaluated by irradiation tests using high-energy heavy ions. We show test results and describe the relationship between observed SEU and structures/fabrication processes. We have evaluated single-even upset (SEU) tolerance of recent commercial memory devices using high energy heavy ions in order to find relationship between SEU rate and their fabrication process. It was revealed that the change of the process parameter gives much effect for the SEU rate of the devices. (authors)

  12. Microstructure and mechanical properties of resistance upset butt welded 304 austenitic stainless steel joints

    International Nuclear Information System (INIS)

    Sharifitabar, M.; Halvaee, A.; Khorshahian, S.

    2011-01-01

    Graphical abstract: Three different microstructural zones formed at different distances from the joint interface in resistance upset butt welding of 304 austenitic stainless steel. Highlights: → Evaluation of microstructure in resistance upset welding of 304 stainless steel. → Evaluation of welding parameters effects on mechanical properties of the joint. → Introducing the optimum welding condition for joining stainless steel bars. -- Abstract: Resistance upset welding (UW) is a widely used process for joining metal parts. In this process, current, time and upset pressure are three parameters that affect the quality of welded products. In the present research, resistance upset butt welding of 304 austenitic stainless steel and effect of welding power and upset pressure on microstructure, tensile strength and fatigue life of the joint were investigated. Microstructure of welds were studied using scanning electron microscopy (SEM). X-ray diffraction (XRD) analysis was used to distinguish the phase(s) that formed at the joint interface and in heat affected zone (HAZ). Energy dispersive spectroscopy (EDS) linked to the SEM was used to determine chemical composition of phases formed at the joint interface. Fatigue tests were performed using a pull-push fatigue test machine and the fatigue properties were analyzed drawing stress-number of cycles to failure (S-N) curves. Also tensile strength tests were performed. Finally tensile and fatigue fracture surfaces were studied by SEM. Results showed that there were three different microstructural zones at different distances from the joint interface and delta ferrite phase has formed in these regions. There was no precipitation of chromium carbide at the joint interface and in the HAZ. Tensile and fatigue strengths of the joint decreased with welding power. Increasing of upset pressure has also considerable influence on tensile strength of the joint. Fractography of fractured samples showed that formation of hot spots at

  13. Charge collection and SEU (Single Event Upset) mechanisms

    International Nuclear Information System (INIS)

    Musseau, O.

    1994-01-01

    The purpose of this paper is to review the mechanisms of single event upset in microelectronic devices due to interaction with cosmic ions. Experimental and theoretical results are presented, and actual questions and problems are discussed. A brief introduction recalls the creation of the dense plasma of electron-hole pairs along the ion track. The basic processes for charge collection in a simple np junction (drift and diffusion) are presented. The funneling-field effect is discussed and experimental results are compared to numerical simulations and semi-empirical models. Charge collection in actual microelectronic structures is then presented. Single event upset of memory cells is discussed, based on numerical and experimental data. The main parameters for device characterization are presented. From the physical interpretation of charge collection mechanisms, the intrinsic sensitivity of various microelectronic technologies is determined and compared to experimental data. Scaling laws and future trends are discussed. (author)

  14. Statistics and methodology of multiple cell upset characterization under heavy ion irradiation

    International Nuclear Information System (INIS)

    Zebrev, G.I.; Gorbunov, M.S.; Useinov, R.G.; Emeliyanov, V.V.; Ozerov, A.I.; Anashin, V.S.; Kozyukov, A.E.; Zemtsov, K.S.

    2015-01-01

    Mean and partial cross-section concepts and their connections to multiplicity and statistics of multiple cell upsets (MCUs) in highly-scaled digital memories are introduced and discussed. The important role of the experimental determination of the upset statistics is emphasized. It was found that MCU may lead to quasi-linear dependence of cross-sections on linear energy transfer (LET). A new form of function for interpolation of mean cross-section dependences on LET has been proposed

  15. A Model for Microcontroller Functionality Upset Induced by External Pulsed Electromagnetic Irradiation

    Science.gov (United States)

    2016-11-21

    AFRL-RD-PS- AFRL-RD-PS- TN-2016-0003 TN-2016-0003 A Model for Microcontroller Functionality Upset Induced by External Pulsed Electromagnetic...TYPE Technical Note 3. DATES COVERED (From - To) 22-11-2015 – 21-11-2016 4. TITLE AND SUBTITLE A Model for Microcontroller Functionality Upset Induced by... microcontroller (µC) subjected to external irradiation by a narrowband electromagnetic (EM) pulse. In our model, the state of a µC is completely specified by

  16. Nuclear data relevant to single-event upsets (SEU) in microelectronics and their application to SEU simulation

    International Nuclear Information System (INIS)

    Watanabe, Yukinobu; Tukamoto, Yasuyuki; Kodama, Akihiro; Nakashima, Hideki

    2004-01-01

    A cross-section database for neutron-induced reactions on 28 Si was developed in the energy range between 2 MeV and 3 GeV in order to analyze single-event upsets (SEUs) phenomena induced by cosmic-ray neutrons in microelectronic devices. A simplified spherical device model was proposed for simulation of the initial process of SEUs. The model was applied to SEU cross-section calculations for semiconductor memory devices. The calculated results were compared with measured SEU cross-sections and the other simulation result. The dependence of SEU cross-sections on incident neutron energy and secondary ions having the most important effects on SEUs are discussed. (author)

  17. Upset in Response to a Sibling’s Partner’s Infidelity

    Directory of Open Access Journals (Sweden)

    Dafni Hellstrand

    2015-08-01

    Full Text Available Existing evidence suggests that the psychological design of romantic jealousy differs for men and women: Men are more likely than women to report greater upset in response to a partner’s sexual than emotional infidelity, whereas women are more likely than men to report greater upset in response to a partner’s emotional than sexual infidelity. However, the observed sex difference can be explained after the fact by both an evolutionary analysis of past reproductive costs and a social constructionist analysis of social and gender role training. Attempting to disentangle these competing perspectives, researchers have measured participants’ upset in response to a sibling’s or a child’s partner’s infidelities. In contrast to what a socialization perspective would predict, participants’ sex did not seem to affect their responses; the key variable was the sex of the sibling or the child, in line with a heuristic application of the evolutionary perspective. The present study attempted not only to test these competing hypotheses but also to extend previous work by involving participants with a gay or lesbian sibling and examining whether participants’ responses are triggered by their sibling’s or sibling’s partner’s sex. In line with an evolutionary perspective, participants’ sex did not assert an effect on their responses. The key variable seemed to be the sex of the sibling (rather than the sex of the sibling’s partner, with participants reporting greater levels of upset in response to the sexual than emotional infidelity of a gay brother’s partner and to the emotional than sexual infidelity of a lesbian sister’s partner. The ensuing discussion offers suggestions for future work on sex-specific triggers of jealousy.

  18. Stability and performance analysis of a jump linear control system subject to digital upsets

    Science.gov (United States)

    Wang, Rui; Sun, Hui; Ma, Zhen-Yang

    2015-04-01

    This paper focuses on the methodology analysis for the stability and the corresponding tracking performance of a closed-loop digital jump linear control system with a stochastic switching signal. The method is applied to a flight control system. A distributed recoverable platform is implemented on the flight control system and subject to independent digital upsets. The upset processes are used to stimulate electromagnetic environments. Specifically, the paper presents the scenarios that the upset process is directly injected into the distributed flight control system, which is modeled by independent Markov upset processes and independent and identically distributed (IID) processes. A theoretical performance analysis and simulation modelling are both presented in detail for a more complete independent digital upset injection. The specific examples are proposed to verify the methodology of tracking performance analysis. The general analyses for different configurations are also proposed. Comparisons among different configurations are conducted to demonstrate the availability and the characteristics of the design. Project supported by the Young Scientists Fund of the National Natural Science Foundation of China (Grant No. 61403395), the Natural Science Foundation of Tianjin, China (Grant No. 13JCYBJC39000), the Scientific Research Foundation for the Returned Overseas Chinese Scholars, State Education Ministry, China, the Tianjin Key Laboratory of Civil Aircraft Airworthiness and Maintenance in Civil Aviation of China (Grant No. 104003020106), and the Fund for Scholars of Civil Aviation University of China (Grant No. 2012QD21x).

  19. In-flight and ground testing of single event upset sensitivity in static RAMs

    International Nuclear Information System (INIS)

    Johansson, K.; Dyreklev, P.; Granbom, B.; Calvet, C.; Fourtine, S.; Feuillatre, O.

    1998-01-01

    This paper presents the results from in-flight measurements of single event upsets (SEU) in static random access memories (SRAM) caused by the atmospheric radiation environment at aircraft altitudes. The memory devices were carried on commercial airlines at high altitude and mainly high latitudes. The SEUs were monitored by a Component Upset Test Equipment (CUTE), designed for this experiment. The in flight results are compared to ground based testing with neutrons from three different sources

  20. Soft error rate estimations of the Kintex-7 FPGA within the ATLAS Liquid Argon (LAr) Calorimeter

    International Nuclear Information System (INIS)

    Wirthlin, M J; Harding, A; Takai, H

    2014-01-01

    This paper summarizes the radiation testing performed on the Xilinx Kintex-7 FPGA in an effort to determine if the Kintex-7 can be used within the ATLAS Liquid Argon (LAr) Calorimeter. The Kintex-7 device was tested with wide-spectrum neutrons, protons, heavy-ions, and mixed high-energy hadron environments. The results of these tests were used to estimate the configuration ram and block ram upset rate within the ATLAS LAr. These estimations suggest that the configuration memory will upset at a rate of 1.1 × 10 −10 upsets/bit/s and the bram memory will upset at a rate of 9.06 × 10 −11 upsets/bit/s. For the Kintex 7K325 device, this translates to 6.85 × 10 −3 upsets/device/s for configuration memory and 1.49 × 10 −3 for block memory

  1. Estimation of the LET threshold of single event upset of microelectronics in experiments with Cf-252

    International Nuclear Information System (INIS)

    Kuznetsov, N.V.; Nymmik, R.A.

    1996-01-01

    A method is proposed for analyzing single event upsets (SEU) in large scale integration circuits of random access memory (RAM) when exposed to Cf-252 fission fragments. The method makes is possible to find the RAM linear energy transfer (LET) threshold to be used for estimations of RAM SEU rates in space. The method is illustrated by analyzing experimental data for the 2 x 8 kbit CMOS/bulk RAM. (author)

  2. Are Sexual and Emotional Infidelity Equally Upsetting to Men and Women? Making Sense of Forced-Choice Responses

    Directory of Open Access Journals (Sweden)

    David A. Lishner

    2008-10-01

    Full Text Available Forced-choice measures that assess reactions to imagined sexual and emotional infidelity are ubiquitous in studies testing the Jealousy as a Specific Innate Module (JSIM model. One potential problem with such measures is that they fail to identify respondents who find both forms of infidelity equally upsetting. To examine this issue, an experiment was conducted in which two groups of participants imagined a romantic infidelity after which participants in the first group used a traditional forced-choice measure to indicate whether they found sexual or emotional infidelity more upsetting. Participants in the second group instead used a modified forced-choice measure that allowed them also to indicate whether they found both forms of infidelity equally upsetting. Consistent with previous research, those given the traditional forced-choice measure tended to respond in a manner that supported the JSIM model. However, the majority of participants given the modified measure indicated that both forms of infidelity were equally upsetting.

  3. Solid-state resistance upset welding: A process with unique advantages for advanced materials

    International Nuclear Information System (INIS)

    Kanne, W.R. Jr.

    1993-01-01

    Solid-state resistance upset welding is suitable for joining many alloys that are difficult to weld using fusion processes. Since no melting takes place, the weld metal retains many of the characteristics of the base metal. Resulting welds have a hot worked structure, and thereby have higher strength than fusion welds in the same mate. Since the material being joined is not melted, compositional gradients are not introduced, second phase materials are minimally disrupted, and minor alloying elements, do not affect weldability. Solid-state upset welding has been adapted for fabrication of structures considered very large compared to typical resistance welding applications. The process has been used for closure of capsules, small vessels, and large containers. Welding emphasis has been on 304L stainless steel, the material for current applications. Other materials have, however, received enough attention to have demonstrated capability for joining alloys that are not readily weldable using fusion welding methods. A variety of other stainless steels (including A-286), superalloys (including TD nickel), refractory metals (including tungsten), and aluminum alloys (including 2024) have been successfully upset welded

  4. Nuclear data relevant to single event upsets in semiconductor memories induced by cosmic-ray neutrons and protons

    International Nuclear Information System (INIS)

    Watanabe, Yukinobu

    2008-01-01

    The role of nuclear data is examined in the study of single event upset (SEU) phenomena in semiconductor memories caused by cosmic-ray neutrons and protons. Neutron and proton SEU cross sections are calculated with a simplified semi-empirical model using experimental heavy-ion SEU cross-sections and a dedicated database of neutron and proton induced reactions on 28 Si. Some impacts of the nuclear reaction data on SEU simulation are analyzed by investigating relative contribution of secondary ions and neutron elastic scattering to SEU and influence of simultaneous multiple ions emission on SEU. (author)

  5. Upset Prevention and Recovery for Unimpaired and Impaired Aircraft, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the project is the development of an on-board envelope estimation, protection and upset recovery tool to address loss of control incidents in...

  6. Tank Z-361 dose rate calculations

    International Nuclear Information System (INIS)

    Richard, R.F.

    1998-01-01

    Neutron and gamma ray dose rates were calculated above and around the 6-inch riser of tank Z-361 located at the Plutonium Finishing Plant. Dose rates were also determined off of one side of the tank. The largest dose rate 0.029 mrem/h was a gamma ray dose and occurred 76.2 cm (30 in.) directly above the open riser. All other dose rates were negligible. The ANSI/ANS 1991 flux to dose conversion factor for neutrons and photons were used in this analysis. Dose rates are reported in units of mrem/h with the calculated uncertainty shown within the parentheses

  7. The educational inclusion of the students with upsets of the oral communication

    Directory of Open Access Journals (Sweden)

    Merling Murguia Moré

    2015-09-01

    Full Text Available The educational inclusion imposes challenges to the National System of Education, to optimize the attention to the students with upsets of the oral communication. Is the objective of the article to share the design of an investigation that assists to the scientific problem how to contribute to the improvement of the educational inclusion of the students with upsets of the oral communication? The employment of the investigation-action-participativa it drives to the execution of the objective related with the construction of a pedagogic model for the improvement of this process. The results of the investigation will constitute a necessary contribution to the educational inclusion in the National System of Education

  8. Single Event Upset in Static Random Access Memories in Atmospheric Neutron Environments

    Science.gov (United States)

    Arita, Yutaka; Takai, Mikio; Ogawa, Izumi; Kishimoto, Tadafumi

    2003-07-01

    Single-event upsets (SEUs) in a 0.4 μm 4 Mbit complementary metal oxide semiconductor (CMOS) static random access memory (SRAM) were investigated in various atmospheric neutron environments at sea level, at an altitude of 2612 m mountain, at an altitude of commercial airplane, and at an underground depth of 476 m. Neutron-induced SEUs increase with the increase in altitude. For a device with a borophosphosilicate glass (BPSG) film, SEU rates induced by thermal neutrons increase with the decrease in the cell charge of a memory cell. A thermal neutron-induced SEU is significant in SRAMs with a small cell charge. With the conditions of small cell charge, thermal neutron-induced SEUs account for 60% or more of the total neutron-induced SEUs. The SEU rate induced by atmospheric thermal neutrons can be estimated by an acceleration test using 252Cf.

  9. Investigation and control of factors influencing resistance upset butt welding.

    NARCIS (Netherlands)

    Kerstens, N.F.H.

    2010-01-01

    The purpose of this work is to investigate the factors influencing the resistance upset butt welding process to obtain an understanding of the metal behaviour and welding process characteristics, so that new automotive steels can be welded with reduced development time and fewer failures in

  10. upSET, the Drosophila homologue of SET3, Is Required for Viability and the Proper Balance of Active and Repressive Chromatin Marks

    Directory of Open Access Journals (Sweden)

    Kyle A. McElroy

    2017-02-01

    Full Text Available Chromatin plays a critical role in faithful implementation of gene expression programs. Different post-translational modifications (PTMs of histone proteins reflect the underlying state of gene activity, and many chromatin proteins write, erase, bind, or are repelled by, these histone marks. One such protein is UpSET, the Drosophila homolog of yeast Set3 and mammalian KMT2E (MLL5. Here, we show that UpSET is necessary for the proper balance between active and repressed states. Using CRISPR/Cas-9 editing, we generated S2 cells that are mutant for upSET. We found that loss of UpSET is tolerated in S2 cells, but that heterochromatin is misregulated, as evidenced by a strong decrease in H3K9me2 levels assessed by bulk histone PTM quantification. To test whether this finding was consistent in the whole organism, we deleted the upSET coding sequence using CRISPR/Cas-9, which we found to be lethal in both sexes in flies. We were able to rescue this lethality using a tagged upSET transgene, and found that UpSET protein localizes to transcriptional start sites (TSS of active genes throughout the genome. Misregulated heterochromatin is apparent by suppressed position effect variegation of the wm4 allele in heterozygous upSET-deleted flies. Using nascent-RNA sequencing in the upSET-mutant S2 lines, we show that this result applies to heterochromatin genes generally. Our findings support a critical role for UpSET in maintaining heterochromatin, perhaps by delimiting the active chromatin environment.

  11. Direct Observation of Asperity Deformation of Specimen with Random Rough Surface in Upsetting Process

    DEFF Research Database (Denmark)

    Azushima, A.; Kuba, S.; Tani, S.

    2004-01-01

    The trapping behavior of liquid lubricant and contact behavior of asperities at the workpiece-tool interface during upsetting and indentation are observed directly using a compression subpress which consists of a transparent die made of sapphire, a microscope with a CCD camera and a video system....... The experiments are carried out without lubricant and with lubricant. Specimens used are commercially pure A1100 Aluminum with a random rough surface. From this observation, the change in the fraction of real contact area is measured by an image processor. The real contact area ratios in upsetting experiment...

  12. A simple analytical model of single-event upsets in bulk CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Sogoyan, Armen V.; Chumakov, Alexander I.; Smolin, Anatoly A., E-mail: aasmol@spels.ru; Ulanova, Anastasia V.; Boruzdina, Anna B.

    2017-06-01

    During the last decade, multiple new methods of single event upset (SEU) rate prediction for aerospace systems have been proposed. Despite different models and approaches being employed in these methods, they all share relatively high usage complexity and require information about a device that is not always available to an end user. This work presents an alternative approach to estimating SEU cross-section as a function of linear energy transfer (LET) that can be further developed into a method of SEU rate prediction. The goal is to propose a simple, yet physics-based, approach with just two parameters that can be used even in situations when only a process node of the device is known. The developed approach is based on geometrical interpretation of SEU cross-section and an analytical solution to the diffusion problem obtained for a simplified IC topology model. A good fit of the model to the experimental data encompassing 7 generations of SRAMs is demonstrated.

  13. Texture evolution maps for upset deformation of body-centered cubic metals

    International Nuclear Information System (INIS)

    Lee, Myoung-Gyu; Wang, Jue; Anderson, Peter M.

    2007-01-01

    Texture evolution maps are used as a tool to visualize texture development during upset deformation in body-centered cubic metals. These maps reveal initial grain orientations that tend toward normal direction (ND)|| versus ND|| . To produce these maps, a finite element analysis (FEA) with a rate-dependent crystal plasticity constitutive relation for tantalum is used. A reference case having zero workpiece/die friction shows that ∼64% of randomly oriented grains rotate toward ND|| and ∼36% rotate toward ND|| . The maps show well-established trends that increasing strain rate sensitivity and decreasing latent-to-self hardening ratio reduce both and percentages, leading to more diffuse textures. Reducing operative slip systems from both {1 1 0}/ and {1 1 2}/ to just {1 1 0}/ has a mixed effect: it increases the percentage but decreases the percentage. Reducing the number of slip systems and increasing the number of FEA integration points per grain strengthen - texture bands that are observed experimentally

  14. A simple analytical model of single-event upsets in bulk CMOS

    International Nuclear Information System (INIS)

    Sogoyan, Armen V.; Chumakov, Alexander I.; Smolin, Anatoly A.; Ulanova, Anastasia V.; Boruzdina, Anna B.

    2017-01-01

    During the last decade, multiple new methods of single event upset (SEU) rate prediction for aerospace systems have been proposed. Despite different models and approaches being employed in these methods, they all share relatively high usage complexity and require information about a device that is not always available to an end user. This work presents an alternative approach to estimating SEU cross-section as a function of linear energy transfer (LET) that can be further developed into a method of SEU rate prediction. The goal is to propose a simple, yet physics-based, approach with just two parameters that can be used even in situations when only a process node of the device is known. The developed approach is based on geometrical interpretation of SEU cross-section and an analytical solution to the diffusion problem obtained for a simplified IC topology model. A good fit of the model to the experimental data encompassing 7 generations of SRAMs is demonstrated.

  15. Causal relationships between solar proton events and single event upsets for communication satellites

    Science.gov (United States)

    Lohmeyer, W. Q.; Cahoy, K.; Liu, Shiyang

    In this work, we analyze a historical archive of single event upsets (SEUs) maintained by Inmarsat, one of the world's leading providers of global mobile satellite communications services. Inmarsat has operated its geostationary communication satellites and collected extensive satellite anomaly and telemetry data since 1990. Over the course of the past twenty years, the satellites have experienced more than 226 single event upsets (SEUs), a catch-all term for anomalies that occur in a satellite's electronics such as bit-flips, trips in power supplies, and memory changes in attitude control systems. While SEUs are seemingly random and difficult to predict, we correlate their occurrences to space weather phenomena, and specifically show correlations between SEUs and solar proton events (SPEs). SPEs are highly energetic protons that originate from solar coronal mass ejections (CMEs). It is thought that when these particles impact geostationary (GEO) satellites they can cause SEUs as well as solar array degradation. We calculate the associated statistical correlations that each SEU occurs within one day, one week, two weeks, and one month of 10 MeV SPEs between 10 - 10,000 particle flux units (pfu). However, we find that SPEs are most prevalent at solar maximum and that the SEUs on Inmarsat's satellites occur out of phase with the solar maximum. Ultimately, this suggests that SPEs are not the primary cause of the Inmarsat SEUs. A better understanding of the causal relationship between SPEs and SEUs will help the satellite communications industry develop component and operational space weather mitigation techniques as well as help the space weather community to refine radiation models.

  16. Single-event phenomena on recent semiconductor devices. Charge-type multiple-bit upsets in high integrated memories

    International Nuclear Information System (INIS)

    Makihara, Akiko; Shindou, Hiroyuki; Nemoto, Norio; Kuboyama, Satoshi; Matsuda, Sumio; Ohshima, Takeshi; Hirao, Toshio; Itoh, Hisayoshi

    2001-01-01

    High integrated memories are used in solid state data recorder (SSDR) of the satellite for accumulating observation data. Single event upset phenomena which turn over an accumulated data in the memory cells are caused by heavy ion incidence. Studies on single-bit upset and multiple-bit upset phenomena in the high integrated memory cells are in progress recently. 16 Mbit DRAM (Dynamic Random Access Memories) and 64 Mbit DRAM are irradiated by heavy ion species, such as iodine, bromine and nickel, in comparison with the irradiation damage in the cosmic environment. Data written on the memory devices are read out after the irradiation. The memory cells in three kinds of states, all of charged state, all of discharged state, and an alternative state of charge and discharge, are irradiated for sorting out error modes caused by heavy ion incidence. The soft error in a single memory cells is known as a turn over from charged state to discharged state. Electrons in electron-hole pair generated by heavy ion incidence are captured in a diffusion region between capacitor electrodes of semiconductor. The charged states in the capacitor electrodes before the irradiation are neutralized and changed to the discharged states. According to high integration of the memories, many of the cells are affected by a single ion incidence. The multiple-bit upsets, however, are generated in the memory cells of discharged state before the irradiation, also. The charge-type multiple-bit upsets is considered as that error data are written on the DRAM during refresh cycle of a sense-up circuit and a pre-charge circuit which control the DRAM. (M. Suetake)

  17. Single event upset in static random access memories in atmospheric neutron environments

    CERN Document Server

    Arita, Y; Ogawa, I; Kishimoto, T

    2003-01-01

    Single-event upsets (SEUs) in a 0.4 mu m 4Mbit complementary metal oxide semiconductor (CMOS) static random access memory (SRAM) were investigated in various atmospheric neutron environments at sea level, at an altitude of 2612 m mountain, at an altitude of commercial airplane, and at an underground depth of 476m. Neutron-induced SEUs increase with the increase in altitude. For a device with a borophosphosilicate glass (BPSG) film, SEU rates induced by thermal neutrons increase with the decrease in the cell charge of a memory cell. A thermal neutron-induced SEU is significant in SRAMs with a small cell charge. With the conditions of small cell charge, thermal neutron-induced SEUs account for 60% or more of the total neutron-induced SEUs. The SEU rate induced by atmospheric thermal neutrons can be estimated by an acceleration test using sup 2 sup 5 sup 2 Cf. (author)

  18. High electrical resistivity Nd-Fe-B die-upset magnet doped with eutectic DyF3–LiF salt mixture

    Directory of Open Access Journals (Sweden)

    K. M. Kim

    2017-05-01

    Full Text Available Nd-Fe-B-type die-upset magnet with high electrical resistivity was prepared by doping of eutectic DyF3–LiF salt mixture. Mixture of melt-spun Nd-Fe-B flakes (MQU-F: Nd13.6Fe73.6Co6.6Ga0.6B5.6 and eutectic binary (DyF3–LiF salt (25 mol% DyF3 – 75 mol% LiF was hot-pressed and then die-upset. By adding the eutectic salt mixture (> 4 wt%, electrical resistivity of the die-upset magnet was enhanced to over 400 μΩ.cm compared to 190 μΩ.cm of the un-doped magnet. Remarkable enhancement of the electrical resistivity was attributed to homogeneous and continuous coverage of the interface between flakes by the easily melted eutectic salt dielectric mixture. It was revealed that active substitution of the Nd atoms in neighboring flakes by the Dy atoms from the added (DyF3–LiF salt mixture had occurred during such a quick thermal processing of hot-pressing and die-upsetting. This Dy substitution led to coercivity enhancement in the die-upset magnet doped with the eutectic (DyF3–LiF salt mixture. Coercivity and remanence of the die-upset magnet doped with (DyF3–LiF salt mixture was as good as those of the DyF3-doped magnet.

  19. Position sensitive regions in a generic radiation sensor based on single event upsets in dynamic RAMs

    International Nuclear Information System (INIS)

    Darambara, D.G.; Spyrou, N.M.

    1997-01-01

    Modern integrated circuits are highly complex systems and, as such, are susceptible to occasional failures. Semiconductor memory devices, particularly dynamic random access memories (dRAMs), are subject to random, transient single event upsets (SEUs) created by energetic ionizing radiation. These radiation-induced soft failures in the stored data of silicon based memory chips provide the foundation for a new, highly efficient, low cost generic radiation sensor. The susceptibility and the detection efficiency of a given dRAM device to SEUs is a complicated function of the circuit design and geometry, the operating conditions and the physics of the charge collection mechanisms involved. Typically, soft error rates measure the cumulative response of all sensitive regions of the memory by broad area chip exposure in ionizing radiation environments. However, this study shows that many regions of a dynamic memory are competing charge collection centres having different upset thresholds. The contribution to soft fails from discrete regions or individual circuit elements of the memory device is unambiguously separated. Hence the use of the dRAM as a position sensitive radiation detector, with high spatial resolution, is assessed and demonstrated. (orig.)

  20. Simulation of thermal-neutron-induced single-event upset using particle and heavy-ion transport code system

    International Nuclear Information System (INIS)

    Arita, Yutaka; Kihara, Yuji; Mitsuhasi, Junichi; Niita, Koji; Takai, Mikio; Ogawa, Izumi; Kishimoto, Tadafumi; Yoshihara, Tsutomu

    2007-01-01

    The simulation of a thermal-neutron-induced single-event upset (SEU) was performed on a 0.4-μm-design-rule 4 Mbit static random access memory (SRAM) using particle and heavy-ion transport code system (PHITS): The SEU rates obtained by the simulation were in very good agreement with the result of experiments. PHITS is a useful tool for simulating SEUs in semiconductor devices. To further improve the accuracy of the simulation, additional methods for tallying the energy deposition are required for PHITS. (author)

  1. Calculating graduation rates.

    Science.gov (United States)

    Starck, Patricia L; Love, Karen; McPherson, Robert

    2008-01-01

    In recent years, the focus has been on increasing the number of registered nurse (RN) graduates. Numerous states have initiated programs to increase the number and quality of students entering nursing programs, and to expand the capacity of their programs to enroll additional qualified students. However, little attention has been focused on an equally, if not more, effective method for increasing the number of RNs produced-increasing the graduation rate of students enrolling. This article describes a project that undertook the task of compiling graduation data for 15 entry-level programs, standardizing terms and calculations for compiling the data, and producing a regional report on graduation rates of RN students overall and by type of program. Methodology is outlined in this article. This effort produced results that were surprising to program deans and directors and is expected to produce greater collaborative efforts to improve these rates both locally and statewide.

  2. Method for strength calculating of structural elements of mobile machines for flash butt welding of rails

    Directory of Open Access Journals (Sweden)

    Andriy Valeriy Moltasov

    2017-12-01

    Full Text Available Purpose. The subject of this study is the strength of the loaded units of mobile machines for flash butt welding by refining high-strength rails. The theme of the work is related to the development of a technique for strength calculating of the insulation of the central axis of these machines. The aim of the paper is to establish the mathematical dependence of the pressure on the insulation on the magnitude of deflections of the central axis under the action of the upset force. Design/methodology/approach. Using the Mohr’s method, the displacements of the investigated sections of the central axis under the action of the upset force and the equivalent load distributed along the length of the insulation were calculated. The magnitude of the load distributed along the length of the insulation equivalent to the draft force was determined from the condition that the displacements of the same cross sections are equal under the action of this load and under the action of the upset force. Results. An analytical expression for establishing the relationship between the pressure acting on the insulation and the magnitude of the upset force and the geometric dimensions of the structural elements of the machine was obtained. Based on the condition of the strength of the insulation for crushing, an analytical expression for establishing the relationship between the length of insulation and the size of the upset force, the geometric dimensions of the structural elements of the machine, and the physical and mechanical properties of the insulation material was obtained. Originality/cost. The proposed methodology was tested in the calculation and design of the K1045 mobile rail welding machine, 4 of which is currently successfully used in the USA for welding rails in hard-to-reach places.

  3. Crying without a cause and being easily upset in two-year-olds: heritability and predictive power of behavioral problems.

    Science.gov (United States)

    Groen-Blokhuis, Maria M; Middeldorp, Christel M; M van Beijsterveldt, Catharina E; Boomsma, Dorret I

    2011-10-01

    In order to estimate the influence of genetic and environmental factors on 'crying without a cause' and 'being easily upset' in 2-year-old children, a large twin study was carried out. Prospective data were available for ~18,000 2-year-old twin pairs from the Netherlands Twin Register. A bivariate genetic analysis was performed using structural equation modeling in the Mx software package. The influence of maternal personality characteristics and demographic and lifestyle factors was tested to identify specific risk factors that may underlie the shared environment of twins. Furthermore, it was tested whether crying without a cause and being easily upset were predictive of later internalizing, externalizing and attention problems. Crying without a cause yielded a heritability estimate of 60% in boys and girls. For easily upset, the heritability was estimated at 43% in boys and 31% in girls. The variance explained by shared environment varied between 35% and 63%. The correlation between crying without a cause and easily upset (r = .36) was explained both by genetic and shared environmental factors. Birth cohort, gestational age, socioeconomic status, parental age, parental smoking behavior and alcohol use during pregnancy did not explain the shared environmental component. Neuroticism of the mother explained a small proportion of the additive genetic, but not of the shared environmental effects for easily upset. Crying without a cause and being easily upset at age 2 were predictive of internalizing, externalizing and attention problems at age 7, with effect sizes of .28-.42. A large influence of shared environmental factors on crying without a cause and easily upset was detected. Although these effects could be specific to these items, we could not explain them by personality characteristics of the mother or by demographic and lifestyle factors, and we recognize that these effects may reflect other maternal characteristics. A substantial influence of genetic factors

  4. Development of a Nuclear Reaction Database on Silicon for Simulation of Neutron-Induced Single-Event Upsets in Microelectronics and its Application

    International Nuclear Information System (INIS)

    Watanabe, Yukinobu; Kodama, Akihiro; Tukamoto, Yasuyuki; Nakashima, Hideki

    2005-01-01

    We have developed a cross-section database for neutron-induced reactions on 28Si in the energy range between 2 MeV and 3 GeV in order to analyze single-event upsets (SEUs) phenomena induced by cosmic-ray neutrons in microelectronic devices. A simplified spherical device model is proposed for simulation of the initial processes of SEUs. The model is applied to SEU cross-section calculations for semiconductor memory devices. The calculated results are compared with measured SEU cross sections and the other simulation result. The dependence of SEU cross sections on incident neutron energy and secondary ions having the most important effects on SEUs are discussed

  5. Development and Flight Testing of an Automated Upset Recovery System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Loss of control (LOC) due to upset is one of the main causes of accidents in manned aircraft and is already emerging as a significant causal factor in unmanned...

  6. Investigation of radial dose effect on single event upset cross-section due to heavy ions using GEANT4

    International Nuclear Information System (INIS)

    Boorboor, S.; Feghhi, S.A.H.; Jafari, H.

    2015-01-01

    The heavy ions are the main cause to produce single event upset (SEU) damage on electronic devices since they are high LET radiations. The dimension of electronic components in new technology, arise a challenge in radiation effect estimations. Accurate investigations require fully considering the ion track in energy deposition as a radial dose distribution. In this work, the distribution of delta rays as well as LET have been calculated to determine ionization structure around ion track by a Monte Carlo code, GEANT4. The radial dose of several heavy ions with different energy in silicon was investigated and compared with the works by other authors in this field. The results showed that heavy ions with identical LET can have different SEU cross-section in silicon transistors. As a demonstrative example, according to our results, the error probability for 4.8 GeV iron was 8 times greater than that for 15 MeV carbon ions, in transistors with new process technology which have small dimension and low critical charges. Our results show that considering radial dose distribution considerably improves the accuracy of the SEU cross-section estimation in electronic devices especially for new technologies. - Highlights: • The single event upset is produced by heavy ions interaction on electronic devices. • The radial dose of several heavy ions in silicon was calculated by GEANT4. • Heavy ions with identical LET had different SEU cross-section in silicon transistors. • Low dimension and critical charge devices were more sensitive to radial dose effect

  7. Final results of the supra project : Improved Simulation of Upset Recovery

    NARCIS (Netherlands)

    Fucke, L.; Groen, E.; Goman, M.; Abramov, N.; Wentink, M.; Nooij, S.; Zaichik, L.E.; Khrabrov, A.

    2012-01-01

    The objective of the European research project SUPRA (Simulation of Upset Recovery in Aviation) is to develop technologies that eventually contribute to a reduction of risk of Loss of control - in flight (LOC-I) accidents, today's major cause of fatal accidents in commercial aviation. To this end

  8. CMOS/SOS RAM transient radiation upset and ''inversion'' effect investigation

    International Nuclear Information System (INIS)

    Nikiforov, A.Y.; Poljakov, I.V.

    1996-01-01

    The Complementary Metal-Oxide-Semiconductor/Silicon-on-Sapphire Random Access Memory (CMOS/SOS RAM) transient upset and inversion effect were investigated with pulsed laser, pulsed voltage generator and low-intensity light simulators. It was found that the inversion of information occurs due to memory cell photocurrents simultaneously with the power supply voltage drop transfer to memory cells outputs

  9. The single event upset environment for avionics at high latitude

    International Nuclear Information System (INIS)

    Sims, A.J.; Dyer, C.S.; Peerless, C.L.; Farren, J.

    1994-01-01

    Modern avionic systems for civil and military applications are becoming increasingly reliant upon embedded microprocessors and associated memory devices. The phenomenon of single event upset (SEU) is well known in space systems and designers have generally been careful to use SEU tolerant devices or to implement error detection and correction (EDAC) techniques where appropriate. In the past, avionics designers have had no reason to consider SEU effects but is clear that the more prevalent use of memory devices combined with increasing levels of IC integration will make SEU mitigation an important design consideration for future avionic systems. To this end, it is necessary to work towards producing models of the avionics SEU environment which will permit system designers to choose components and EDAC techniques which are based on predictions of SEU rates correct to much better than an order of magnitude. Measurements of the high latitude SEU environment at avionics altitude have been made on board a commercial airliner. Results are compared with models of primary and secondary cosmic rays and atmospheric neutrons. Ground based SEU tests of static RAMs are used to predict rates in flight

  10. Ductile failure in upsetting of a rapid-solidification-processed aluminium alloy

    NARCIS (Netherlands)

    Habraken, F.A.C.M.; Dautzenberg, J.H.

    1993-01-01

    Cold upset-tests have been performed on a Rapid Solidification Processed (RSP) aluminium-alloy, produced by the ‘melt-spun ribbons’-process out of 70% car-scrap and 30% primary scrap. The ribbons are hot extruded, resulting in 29 mm diameter bar. Its properties regarding plastic flow and fracture

  11. Solar particle induced upsets in the TDRS-1 attitude control system RAM during the October 1989 solar particle events

    International Nuclear Information System (INIS)

    Croley, D.R.; Garrett, H.B.; Murphy, G.B.; Garrard, T.L.

    1995-01-01

    The three large solar particle events, beginning on October 19, 1989 and lasting approximately six days, were characterized by high fluences of solar protons and heavy ions at 1 AU. During these events, an abnormally large number of upsets (243) were observed in the random access memory of the attitude control system (ACS) control processing electronics (CPE) on-board the geosynchronous TDRS-1 (Telemetry and Data Relay Satellite). The RAM unit affected was composed of eight Fairchild 93L422 memory chips. The Galileo spacecraft, launched on October 18, 1989 (one day prior to the solar particle events) observed the fluxes of heavy ions experienced by TDRS-1. Two solid-state detector telescopes on-board Galileo, designed to measure heavy ion species and energy, were turned on during time periods within each of the three separate events. The heavy ion data have been modeled and the time history of the events reconstructed to estimate heavy ion fluences. These fluences were converted to effective LET spectra after transport through the estimated shielding distribution around the TDRS-1 ACS system. The number of single event upsets (SEU) expected was calculated by integrating the measured cross section for the Fairchild 93L422 memory chip with average effective LET spectrum. The expected number of heavy ion induced SEU's calculated was 176. GOES-7 proton data, observed during the solar particle events, were used to estimate the number of proton-induced SEU's by integrating the proton fluence spectrum incident on the memory chips, with the two-parameter Bendel cross section for proton SEU's. The proton fluence spectrum at the device level was gotten by transporting the protons through the estimated shielding distribution. The number of calculated proton-induced SEU's was 72, yielding a total of 248 predicted SEU's, very close to the 243 observed SEU's

  12. Calculating the Rate of Senescence From Mortality Data

    DEFF Research Database (Denmark)

    Koopman, Jacob J E; Rozing, Maarten P; Kramer, Anneke

    2016-01-01

    , they do not fit mortality rates at young and old ages. Therefore, we developed a method to calculate senescence rates from the acceleration of mortality directly without modeling the mortality rates. We applied the different methods to age group-specific mortality data from the European Renal Association......, the rate of senescence can be calculated directly from non-modeled mortality rates, overcoming the disadvantages of an indirect estimation based on modeled mortality rates....

  13. Reaction rate calculations via transmission coefficients

    International Nuclear Information System (INIS)

    Feit, M.D.; Alder, B.J.

    1985-01-01

    The transmission coefficient of a wavepacket traversing a potential barrier can be determined by steady state calculations carried out in imaginary time instead of by real time dynamical calculations. The general argument is verified for the Eckart barrier potential by a comparison of transmission coefficients calculated from real and imaginary time solutions of the Schroedinger equation. The correspondence demonstrated here allows a formulation for the reaction rate that avoids difficulties due to both rare events and explicitly time dependent calculations. 5 refs., 2 figs

  14. Direct observation of asperity deformation of specimens with random rough surfaces in upsetting and indentation processes

    DEFF Research Database (Denmark)

    Azushima, A.; Kuba, S.; Tani, S.

    2006-01-01

    The trapping behavior of liquid lubricant and contact behavior of asperities at the workpiece-tool interface during upsetting and indentation are observed directly using a compression subpress which consists of a transparent die made of sapphire, a microscope with a CCD camera and a video system....... The experiments are carried out without lubricant and with lubricant. Specimens used are commercially pure A1100 aluminum with a random rough surface. From these observations, the change in the fraction of real contact area is measured by an image processor. The real contact area ratios in upsetting experiments...

  15. Solar Particle Induced Upsets in the TDRS-1 Attitude Control System RAM During the October 1989 Solar Particle Events

    Science.gov (United States)

    Croley, D. R.; Garrett, H. B.; Murphy, G. B.; Garrard,T. L.

    1995-01-01

    The three large solar particle events, beginning on October 19, 1989 and lasting approximately six days, were characterized by high fluences of solar protons and heavy ions at 1 AU. During these events, an abnormally large number of upsets (243) were observed in the random access memory of the attitude control system (ACS) control processing electronics (CPE) on-board the geosynchronous TDRS-1 (Telemetry and Data Relay Satellite). The RAM unit affected was composed of eight Fairchild 93L422 memory chips. The Galileo spacecraft, launched on October 18, 1989 (one day prior to the solar particle events) observed the fluxes of heavy ions experienced by TDRS-1. Two solid-state detector telescopes on-board Galileo, designed to measure heavy ion species and energy, were turned on during time periods within each of the three separate events. The heavy ion data have been modeled and the time history of the events reconstructed to estimate heavy ion fluences. These fluences were converted to effective LET spectra after transport through the estimated shielding distribution around the TDRS-1 ACS system. The number of single event upsets (SEU) expected was calculated by integrating the measured cross section for the Fairchild 93L422 memory chip with average effective LET spectrum. The expected number of heavy ion induced SEU's calculated was 176. GOES-7 proton data, observed during the solar particle events, were used to estimate the number of proton-induced SEU's by integrating the proton fluence spectrum incident on the memory chips, with the two-parameter Bendel cross section for proton SEU'S. The proton fluence spectrum at the device level was gotten by transporting the protons through the estimated shielding distribution. The number of calculated proton-induced SEU's was 72, yielding a total of 248 predicted SEU'S, very dose to the 243 observed SEU'S. These calculations uniquely demonstrate the roles that solar heavy ions and protons played in the production of SEU

  16. Dose rate calculations for a reconnaissance vehicle

    International Nuclear Information System (INIS)

    Grindrod, L.; Mackey, J.; Salmon, M.; Smith, C.; Wall, S.

    2005-01-01

    A Chemical Nuclear Reconnaissance System (CNRS) has been developed by the British Ministry of Defence to make chemical and radiation measurements on contaminated terrain using appropriate sensors and recording equipment installed in a land rover. A research programme is under way to develop and validate a predictive capability to calculate the build-up of contamination on the vehicle, radiation detector performance and dose rates to the occupants of the vehicle. This paper describes the geometric model of the vehicle and the methodology used for calculations of detector response. Calculated dose rates obtained using the MCBEND Monte Carlo radiation transport computer code in adjoint mode are presented. These address the transient response of the detectors as the vehicle passes through a contaminated area. Calculated dose rates were found to agree with the measured data to be within the experimental uncertainties, thus giving confidence in the shielding model of the vehicle and its application to other scenarios. (authors)

  17. Assessing the reliability of calculated catalytic ammonia synthesis rates

    DEFF Research Database (Denmark)

    Medford, Andrew James; Wellendorff, Jess; Vojvodic, Aleksandra

    2014-01-01

    We introduce a general method for estimating the uncertainty in calculated materials properties based on density functional theory calculations. We illustrate the approach for a calculation of the catalytic rate of ammonia synthesis over a range of transition-metal catalysts. The correlation...... between errors in density functional theory calculations is shown to play an important role in reducing the predicted error on calculated rates. Uncertainties depend strongly on reaction conditions and catalyst material, and the relative rates between different catalysts are considerably better described...

  18. Swift heavy ion induced single event upsets in high density UV-EPROM's

    Energy Technology Data Exchange (ETDEWEB)

    Dahiwale, S.S. [Department of Physics, University of Pune, Pune 7 (India); Shinde, N.S. [Department of Chemical Engineering, Mie University (Japan); Kanjilal, D. [Inter University Accelerator Center, New Delhi (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Pune 7 (India); Dhole, S.D. [Department of Physics, University of Pune, Pune 7 (India)], E-mail: sanjay@physics.unipune.ernet.in

    2008-04-15

    A few high density UV-EPROM's (32Kb x 8) were irradiated with 5.41 MeV energy {alpha}-particles with fluences from 10{sup 4} to 10{sup 8} alphas/cm{sup 2} and 100 MeV nickel, iodine and silver ions for low fluences between 5 x 10{sup 7} and 10{sup 8} ions/cm{sup 2}. The energy and ion species was selected on the basis of predicted threshold values of linear energy transfer (LET) in silicon. The program which was stored in the memory found to be changed from 0 to 1 and 1 to 0 state, respectively. On the basis of changed states, the cross-sections ({sigma}) were calculated to investigate the single event effects/upsets. No upset was observed in case of {alpha}-particle since it has very low LET, but the SEU cross-section found to be more in case of Iodine i.e. 2.29 x 10{sup -3} cm{sup 2} than that of nickel, 2.12 x 10{sup -3} cm{sup 2} and silver, 2.26 x 10{sup -3}. This mainly attributes that LET for iodine is more as compared to silver and nickel ions, which deposits large amount of energy near the sensitive node of memory cell in the form of electron-hole pairs required to change the state. These measured SEU cross-section were also compared with theoretically predicted values along with the Weibull distribution fit to the ion induced experimental SEU data. The theoretical predicted SEU cross-section 3.27 x 10{sup -3} cm{sup 2} found to be in good agreement with the measured SEU cross-section.

  19. Updates to In-Line Calculation of Photolysis Rates

    Science.gov (United States)

    How photolysis rates are calculated affects ozone and aerosol concentrations predicted by the CMAQ model and the model?s run-time. The standard configuration of CMAQ uses the inline option that calculates photolysis rates by solving the radiative transfer equation for the needed ...

  20. 49 CFR 1141.1 - Procedures to calculate interest rates.

    Science.gov (United States)

    2010-10-01

    ... the portion of the year covered by the interest rate. A simple multiplication of the nominal rate by... 49 Transportation 8 2010-10-01 2010-10-01 false Procedures to calculate interest rates. 1141.1... TRANSPORTATION BOARD, DEPARTMENT OF TRANSPORTATION RULES OF PRACTICE PROCEDURES TO CALCULATE INTEREST RATES...

  1. The rating reliability calculator

    Directory of Open Access Journals (Sweden)

    Solomon David J

    2004-04-01

    Full Text Available Abstract Background Rating scales form an important means of gathering evaluation data. Since important decisions are often based on these evaluations, determining the reliability of rating data can be critical. Most commonly used methods of estimating reliability require a complete set of ratings i.e. every subject being rated must be rated by each judge. Over fifty years ago Ebel described an algorithm for estimating the reliability of ratings based on incomplete data. While his article has been widely cited over the years, software based on the algorithm is not readily available. This paper describes an easy-to-use Web-based utility for estimating the reliability of ratings based on incomplete data using Ebel's algorithm. Methods The program is available public use on our server and the source code is freely available under GNU General Public License. The utility is written in PHP, a common open source imbedded scripting language. The rating data can be entered in a convenient format on the user's personal computer that the program will upload to the server for calculating the reliability and other statistics describing the ratings. Results When the program is run it displays the reliability, number of subject rated, harmonic mean number of judges rating each subject, the mean and standard deviation of the averaged ratings per subject. The program also displays the mean, standard deviation and number of ratings for each subject rated. Additionally the program will estimate the reliability of an average of a number of ratings for each subject via the Spearman-Brown prophecy formula. Conclusion This simple web-based program provides a convenient means of estimating the reliability of rating data without the need to conduct special studies in order to provide complete rating data. I would welcome other researchers revising and enhancing the program.

  2. East Area Irradiation Test Facility: Preliminary FLUKA calculations

    CERN Document Server

    Lebbos, E; Calviani, M; Gatignon, L; Glaser, M; Moll, M; CERN. Geneva. ATS Department

    2011-01-01

    In the framework of the Radiation to Electronics (R2E) mitigation project, the testing of electronic equipment in a radiation field similar to the one occurring in the LHC tunnel and shielded areas to study its sensitivity to single even upsets (SEU) is one of the main topics. Adequate irradiation test facilities are therefore required, and one installation is under consideration in the framework of the PS East area renovation activity. FLUKA Monte Carlo calculations were performed in order to estimate the radiation field which could be obtained in a mixed field facility using the slowly extracted 24 GeV/c proton beam from the PS. The prompt ambient dose equivalent as well as the equivalent residual dose rate after operation was also studied and results of simulations are presented in this report.

  3. Fair and Reasonable Rate Calculation Data -

    Data.gov (United States)

    Department of Transportation — This dataset provides guidelines for calculating the fair and reasonable rates for U.S. flag vessels carrying preference cargoes subject to regulations contained at...

  4. Investigation and control of factors influencing resistance upset butt welding.

    OpenAIRE

    Kerstens, N.F.H.

    2010-01-01

    The purpose of this work is to investigate the factors influencing the resistance upset butt welding process to obtain an understanding of the metal behaviour and welding process characteristics, so that new automotive steels can be welded with reduced development time and fewer failures in production. In principle the welding process is rather simple, the materials to be joined are clamped between two electrodes and pressed together. Because there is an interface present with a higher resist...

  5. Effect of material parameters on stress wave propagation during fast upsetting

    Institute of Scientific and Technical Information of China (English)

    WANG Zhong-jin; CHENG Li-dong

    2008-01-01

    Based'on a dynamic analysis method and an explicit algorithm, a dynamic explicit finite element code was developed for modeling the fast upsetting process of block under drop hammer impact, in which the hammer velocity during the deformation was calculated by energy conservation law according to the operating principle of hammer equipment. The stress wave propagation and its effect on the deformation were analyzed by the stress and strain distributions. Industrial pure lead, oxygen-free high-conductivity (OFHC) copper and 7039 aluminum alloy were chosen to investigate the effect of material parameters on the stress wave propagation. The results show that the stress wave propagates from top to bottom of block, and then reflects back when it reaches the bottom surface. After that, stress wave propagates and reflects repeatedly between the upper surface and bottom surface. The stress wave propagation has a significant effect on the deformation at the initial stage, and then becomes weak at the middle-final stage. When the ratio of elastic modulus or the slope of stress-strain curve to mass density becomes larger, the velocity of stress wave propagation increases, and the influence of stress wave on the deformation becomes small.

  6. Impact ionisation rate calculations in wide band gap semiconductors

    International Nuclear Information System (INIS)

    Harrison, D.

    1998-09-01

    Calculations of band-to-band impact ionisation rates performed in the semi-classical Fermi's Golden Rule approximation are presented here for the semiconductors GaAs, In 0.53 Ga 0.47 As and Si 0.5 Ge 0.5 at 300K. The crystal band structure is calculated using the empirical pseudopotential method. To increase the speed with which band structure data at arbitrary k-vectors can be obtained, an interpolation scheme has been developed. Energies are quadratically interpolated on adapted meshes designed to ensure accuracy is uniform throughout the Brillouin zone, and pseudowavefunctions are quadratically interpolated on a regular mesh. Matrix elements are calculated from the pseudowavefunctions, and include the terms commonly neglected in calculations for narrow band gap materials and an isotropic approximation to the full wavevector and frequency dependent dielectric function. The numerical integration of the rate over all distinct energy and wavevector conserving transitions is performed using two different algorithms. Results from each are compared and found to be in good agreement, indicating that the algorithms are reliable. The rates for electrons and holes in each material are calculated as functions of the k-vector of the impacting carriers, and found to be highly anisotropic. Average rates for impacting carriers at a given energy are calculated and fitted to Keldysh-type expressions with higher than quadratic dependence of the rate on energy above threshold being obtained in all cases. The average rates calculated here are compared to results obtained by other workers, with reasonable agreement being obtained for GaAs, and poorer agreement obtained for InGaAs and SiGe. Possible reasons for the disagreement are investigated. The impact ionisation thresholds are examined and k-space and energy distributions of generated carriers are determined. The role of threshold anisotropy, variation in the matrix elements and the shape of the bands in determining

  7. Acquisition and classification of static single-event upset cross section for SRAM-based FPGAs

    International Nuclear Information System (INIS)

    Yao Zhibin; Fan Ruyu; Guo Hongxia; Wang Zhongming; He Baoping; Zhang Fengqi; Zhang Keying

    2011-01-01

    In order to evaluate single event upsets (SEUs) in SRAM-based FPGAs and to find the sensitive resource in configuration memory, a heavy ions irradiation experiment was carried out on a Xilinx FPGAs device XCV300PQ240. The experiment was conducted to gain the static SEU cross section and classify the SEUs in configurations memory according to different resource uses. The results demonstrate that the inter-memory of SRAM-based FPGAs is extremely sensitive to heavy-ion-induced SEUs. The LUT and routing resources are the main source of SEUs in the configuration memory, which covers more than 97.46% of the total upsets. The SEU sensitivity of various resources is different. The IOB control bit and LUT elements are more sensitive,and more attention should be paid to the LUT elements in radiation hardening,which account for a quite large proportion of the configuration memory. (authors)

  8. Single Event Upset Energy Dependence In a Buck-Converter Power Supply Design

    CERN Document Server

    Drake, G; The ATLAS collaboration; Gopalakrishnan, A; Mahadik, S; Mellado, B; Proudfoot, J; Reed, R; Senthilkumaran, A; Stanek, R

    2012-01-01

    We present a study of Single Event Upsets (SEU) performed on a commercial pulse-width modulator controller chip for switching power supplies. We performed tests to study the probability of an SEU occurring as a function of incident particle (hadron) energy. We discuss the performance of the circuit, and present a solution using external circuitry to effectively eliminate the effect.

  9. Device simulation of charge collection and single-event upset

    International Nuclear Information System (INIS)

    Dodd, P.E.

    1996-01-01

    In this paper the author reviews the current status of device simulation of ionizing-radiation-induced charge collection and single-event upset (SEU), with an emphasis on significant results of recent years. The author presents an overview of device-modeling techniques applicable to the SEU problem and the unique challenges this task presents to the device modeler. He examines unloaded simulations of radiation-induced charge collection in simple p/n diodes, SEU in dynamic random access memories (DRAM's), and SEU in static random access memories (SRAM's). The author concludes with a few thoughts on future issues likely to confront the SEU device modeler

  10. The calculation of dose rates from rectangular sources

    International Nuclear Information System (INIS)

    Hartley, B.M.

    1998-01-01

    A common problem in radiation protection is the calculation of dose rates from extended sources and irregular shapes. Dose rates are proportional to the solid angle subtended by the source at the point of measurement. Simple methods of calculating solid angles would assist in estimating dose rates from large area sources and therefore improve predictive dose estimates when planning work near such sources. The estimation of dose rates is of particular interest to producers of radioactive ores but other users of bulk radioactive materials may have similar interest. The use of spherical trigonometry can assist in determination of solid angles and a simple equation is derived here for the determination of the dose at any distance from a rectangular surface. The solid angle subtended by complex shapes can be determined by modelling the area as a patchwork of rectangular areas and summing the solid angles from each rectangle. The dose rates from bags of thorium bearing ores is of particular interest in Western Australia and measured dose rates from bags and containers of monazite are compared with theoretical estimates based on calculations of solid angle. The agreement is fair but more detailed measurements would be needed to confirm the agreement with theory. (author)

  11. Evaluation of the upset risk in CMOS SRAM through full three dimensional simulation

    International Nuclear Information System (INIS)

    Moreau, Y.; Gasiot, J.; Duzellier, S.

    1995-01-01

    Upsets caused by incident heavy ion on CMOS static RAM are studied here. Three dimensional device simulations, based on a description of a full epitaxial CMOS inverter, and experimental results are reported for evaluation of single and multiple bit error risk. The particular influences of hit location and incidence angle are examined

  12. Prediction of particle orientation in simple upsetting process of NdFeB magnets

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Chao-Cheng; Hsiao, Po-Jen [Department of Mold and Die Engineering, National Kaohsiung University of Applied Sciences, 415 Chien-Kung Road, Sanmin District, Kaohsiung 80778, Taiwan (China); You, Jr-Shiang; Chen, Yen-Ju; Chang, Can-Xun [Metal Forming Technology Section, Metal Processing R and D Department, Metal Industries Research and Development Centre, 1001 Kaonan Highway, Kaohsiung 81160, Taiwan (China)

    2013-12-16

    The magnetic properties of NdFeB magnets are strongly affected by crystallographic texture which is highly associated with particle orientation. This study proposed a method for predicting the particle orientation in the simple upsetting process of NdFeB magnets. The method is based on finite element simulation with flow net analysis. The magnets in a cylindrical form were compressed by two flat dies in a chamber filled with argon at 750°C. Three forming speeds were taken into account in order to obtain flow stress curves used in simulations. The micrographs of the cross sections of the deformed magnets show that the particle deformation significantly increases with the compression. The phenomenon was also predicted by the proposed method. Both simulated and experimental results show that the inhomogeneity of the texture of the NdFeB magnets can be increased by the simple upsetting process. The predicted particle orientations were in a good agreement with those examined in the deformed magnets. The proposed method for predicting particle orientations can also be used in other forming processes of NdFeB magnets.

  13. Prediction of particle orientation in simple upsetting process of NdFeB magnets

    International Nuclear Information System (INIS)

    Chang, Chao-Cheng; Hsiao, Po-Jen; You, Jr-Shiang; Chen, Yen-Ju; Chang, Can-Xun

    2013-01-01

    The magnetic properties of NdFeB magnets are strongly affected by crystallographic texture which is highly associated with particle orientation. This study proposed a method for predicting the particle orientation in the simple upsetting process of NdFeB magnets. The method is based on finite element simulation with flow net analysis. The magnets in a cylindrical form were compressed by two flat dies in a chamber filled with argon at 750°C. Three forming speeds were taken into account in order to obtain flow stress curves used in simulations. The micrographs of the cross sections of the deformed magnets show that the particle deformation significantly increases with the compression. The phenomenon was also predicted by the proposed method. Both simulated and experimental results show that the inhomogeneity of the texture of the NdFeB magnets can be increased by the simple upsetting process. The predicted particle orientations were in a good agreement with those examined in the deformed magnets. The proposed method for predicting particle orientations can also be used in other forming processes of NdFeB magnets

  14. Comparison of analytical models and experimental results for single-event upset in CMOS SRAMs

    International Nuclear Information System (INIS)

    Mnich, T.M.; Diehl, S.E.; Shafer, B.D.

    1983-01-01

    In an effort to design fully radiation-hardened memories for satellite and deep-space applications, a 16K and a 2K CMOS static RAM were modeled for single-particle upset during the design stage. The modeling resulted in the addition of a hardening feedback resistor in the 16K remained tentatively unaltered. Subsequent experiments, using the Lawrence Berkeley Laboratories' 88-inch cyclotron to accelerate krypton and oxygen ions, established an upset threshold for the 2K and the 16K without resistance added, as well as a hardening threshold for the 16K with feedback resistance added. Results for the 16K showed it to be hardenable to the higher level than previously published data for other unhardened 16K RAMs. The data agreed fairly well with the modeling results; however, a close look suggests that modification of the simulation methodology is required to accurately predict the resistance necessary to harden the RAM cell

  15. APUAMA: a software tool for reaction rate calculations.

    Science.gov (United States)

    Euclides, Henrique O; P Barreto, Patricia R

    2017-06-01

    APUAMA is a free software designed to determine the reaction rate and thermodynamic properties of chemical species of a reagent system. With data from electronic structure calculations, the APUAMA determine the rate constant with tunneling correction, such as Wigner, Eckart and small curvature, and also, include the rovibrational level of diatomic molecules. The results are presented in the form of Arrhenius-Kooij form, for the reaction rate, and the thermodynamic properties are written down in the polynomial form. The word APUAMA means "fast" in Tupi-Guarani Brazilian language, then the code calculates the reaction rate on a simple and intuitive graphic interface, the form fast and practical. As program output, there are several ASCII files with tabulated information for rate constant, rovibrational levels, energy barriers and enthalpy of reaction, Arrhenius-Kooij coefficient, and also, the option to the User save all graphics in BMP format.

  16. NEPP Update of Independent Single Event Upset Field Programmable Gate Array Testing

    Science.gov (United States)

    Berg, Melanie; Label, Kenneth; Campola, Michael; Pellish, Jonathan

    2017-01-01

    This presentation provides a NASA Electronic Parts and Packaging (NEPP) Program update of independent Single Event Upset (SEU) Field Programmable Gate Array (FPGA) testing including FPGA test guidelines, Microsemi RTG4 heavy-ion results, Xilinx Kintex-UltraScale heavy-ion results, Xilinx UltraScale+ single event effect (SEE) test plans, development of a new methodology for characterizing SEU system response, and NEPP involvement with FPGA security and trust.

  17. Implications of the spatial dependence of the single-event-upset threshold in SRAMs measured with a pulsed laser

    International Nuclear Information System (INIS)

    Buchner, S.; Langworthy, J.B.; Stapor, W.J.; Campbell, A.B.; Rivet, S.

    1994-01-01

    Pulsed laser light was used to measure single event upset (SEU) thresholds for a large number of memory cells in both CMOS and bipolar SRAMs. Results showed that small variations in intercell upset threshold could not explain the gradual rise in the curve of cross section versus linear energy transfer (LET). The memory cells exhibited greater intracell variations implying that the charge collection efficiency within a memory cell varies spatially and contributes substantially to the shape of the curve of cross section versus LET. The results also suggest that the pulsed laser can be used for hardness-assurance measurements on devices with sensitive areas larger than the diameter of the laser beam

  18. FABGEN, a transient power-generation and isotope birth rate calculator

    International Nuclear Information System (INIS)

    Roland, H.C.

    1975-04-01

    A description is given of the FABGEN program, a fast-running program for calculating fuel element power-generation rates and selected fission product birth rates in a known neutron flux as functions of time. A first forward difference calculation is used, and the time step is one day. Provisions are made for including various fuel element lengths, variation of thermal flux with time, and use of different fertile isotopes. Five different fission products may be specified for birth-rate calculations. A daily summary may be output, or totals by days may be accumulated for final output. (U.S.)

  19. Simulation Study of Flap Effects on a Commercial Transport Airplane in Upset Conditions

    Science.gov (United States)

    Cunningham, Kevin; Foster, John V.; Shah, Gautam H.; Stewart, Eric C.; Ventura, Robin N.; Rivers, Robert A.; Wilborn, James E.; Gato, William

    2005-01-01

    As part of NASA's Aviation Safety and Security Program, a simulation study of a twinjet transport airplane crew training simulation was conducted to address fidelity for upset or loss of control conditions and to study the effect of flap configuration in those regimes. Piloted and desktop simulations were used to compare the baseline crew training simulation model with an enhanced aerodynamic model that was developed for high-angle-of-attack conditions. These studies were conducted with various flap configurations and addressed the approach-to-stall, stall, and post-stall flight regimes. The enhanced simulation model showed that flap configuration had a significant effect on the character of departures that occurred during post-stall flight. Preliminary comparisons with flight test data indicate that the enhanced model is a significant improvement over the baseline. Some of the unrepresentative characteristics that are predicted by the baseline crew training simulation for flight in the post-stall regime have been identified. This paper presents preliminary results of this simulation study and discusses key issues regarding predicted flight dynamics characteristics during extreme upset and loss-of-control flight conditions with different flap configurations.

  20. Some aspects of barreling in sintered plain carbon steel powder metallurgy preforms during cold upsetting

    Directory of Open Access Journals (Sweden)

    Sumesh Narayan

    2012-04-01

    Full Text Available The present research establishes a relationship of bulged diameter with densification and hydrostatic stress in forming of sintered iron (Fe powder metallurgy preforms cold upset under two different frictional conditions, namely, nil/no and graphite lubricant condition. Sintered plain carbon steel cylindrical preforms with carbon (C contents of 0, 0.35, 0.75 and 1.1% with constant initial theoretical density of 84% and aspect ratio of 0.4 and 0.6 were prepared using a suitable die-set assembly on a 1 MN capacity hydraulic press and sintered for 90 minutes at 1200 °C. Each sintered preform was cold upset under two different frictional constraints. It is seen that the degree of bulging reduces with reducing frictional constraints at the die contact surface. Further, it is found that the bulging ratio changed as a function of relative density and hydrostatic stress, respectively, according to the power law equations.

  1. Effect of Friction on Barreling during cold Upset Forging of Aluminium 6082 Alloy Solid cylinders

    Science.gov (United States)

    Priyadarshini, Amrita; Kiran, C. P.; Suresh, K.

    2018-03-01

    Friction is one of the significant factors in forging operations since it affects metal flow in the die, forming load, strain distribution, tool and die life, surface quality of the product etc. In upset forging, the frictional forces at the die-workpiece interface oppose the outward flow of the material due to which the specimen develops a barrel shape. As a result, the deformation becomes non-uniform or inhomogeneous which is undesirable. Barreling can be reduced by applying effective lubricant on the surface of the platens. The objective of the present work is to study experimentally the effect of various frictional conditions (dry, grease, mineral oil) on barreling during upset forging of aluminum 6082 solid cylinders of different aspect ratio (length/diameter: 0.5, 0.75, 1). The friction coefficients are determined using the ring compression test. Curvature of barrel is determined based on the assumption that the curvature of the barrel follows the geometry of circular arc.

  2. Empirical rate equation model and rate calculations of hydrogen generation for Hanford tank waste

    International Nuclear Information System (INIS)

    HU, T.A.

    1999-01-01

    Empirical rate equations are derived to estimate hydrogen generation based on chemical reactions, radiolysis of water and organic compounds, and corrosion processes. A comparison of the generation rates observed in the field with the rates calculated for twenty eight tanks shows agreement within a factor of two to three

  3. Calculation methods for dissolution rate of multicomponent alloys during electrochemical machining

    International Nuclear Information System (INIS)

    Dikusar, A.I.; Petrenko, V.I.; Dikusar, G.K.; Ehngel'gardt, G.R.; Michukova, N.Yu.

    1981-01-01

    The possibility of theoretical calculation of metal dissolution rate during electrochemical mashining is considered. Two calculation techniques are compared at the example of two-component W-Re, Ni-W, Mo-Re alloys, namely: ''charge superposition'' and ''weight percents''. It is concluded that the technique of ''charge superposition'' is the only grounded calculation technique of specific rates of dissolution for alloys [ru

  4. Exact comparison of dose rate measurements and calculation of TN12/2 packages

    International Nuclear Information System (INIS)

    Taniuchi, H.; Matsuda, F.

    1998-01-01

    Both of dose rate measurements of TN 12/2 package and calculations by Monte Carlo code MORSE in SCALE code system and MCNP were performed to evaluate the difference between the measurement and the calculation and finding out the cause of the difference. The calculated gamma-ray dose rates agreed well with measured ones, but calculated neutron dose rates overestimated more than a factor of 1.7. When considering the cause of the difference and applying the modification into the neutron calculation, the calculated neutron dose rates become to agree well, and the factor decreased to around 1.3. (authors)

  5. Photoionization cross sections and Auger rates calculated by many-body perturbation theory

    International Nuclear Information System (INIS)

    Kelly, H.P.

    1976-01-01

    Methods for applying the many body perturbation theory to atomic calculations are discussed with particular emphasis on calculation of photoionization cross sections and Auger rates. Topics covered include: Rayleigh--Schroedinger theory; many body perturbation theory; calculations of photoionization cross sections; and Auger rates

  6. Efficient calculation of atomic rate coefficients in dense plasmas

    Science.gov (United States)

    Aslanyan, Valentin; Tallents, Greg J.

    2017-03-01

    Modelling electron statistics in a cold, dense plasma by the Fermi-Dirac distribution leads to complications in the calculations of atomic rate coefficients. The Pauli exclusion principle slows down the rate of collisions as electrons must find unoccupied quantum states and adds a further computational cost. Methods to calculate these coefficients by direct numerical integration with a high degree of parallelism are presented. This degree of optimization allows the effects of degeneracy to be incorporated into a time-dependent collisional-radiative model. Example results from such a model are presented.

  7. Relativistic quasiparticle random-phase approximation calculation of total muon capture rates

    International Nuclear Information System (INIS)

    Marketin, T.; Paar, N.; Niksic, T.; Vretenar, D.

    2009-01-01

    The relativistic proton-neutron quasiparticle random phase approximation (pn-RQRPA) is applied in the calculation of total muon capture rates on a large set of nuclei from 12 C to 244 Pu, for which experimental values are available. The microscopic theoretical framework is based on the relativistic Hartree-Bogoliubov (RHB) model for the nuclear ground state, and transitions to excited states are calculated using the pn-RQRPA. The calculation is fully consistent, i.e., the same interactions are used both in the RHB equations that determine the quasiparticle basis, and in the matrix equations of the pn-RQRPA. The calculated capture rates are sensitive to the in-medium quenching of the axial-vector coupling constant. By reducing this constant from its free-nucleon value g A =1.262 by 10% for all multipole transitions, the calculation reproduces the experimental muon capture rates to better than 10% accuracy.

  8. Analysis by Monte Carlo simulations of the sensitivity to single event upset of SRAM memories under spatial proton or terrestrial neutron environment

    International Nuclear Information System (INIS)

    Lambert, D.

    2006-07-01

    Electronic systems in space and terrestrial environments are subjected to a flow of particles of natural origin, which can induce dysfunctions. These particles can cause Single Event Upsets (SEU) in SRAM memories. Although non-destructive, the SEU can have consequences on the equipment functioning in applications requiring a great reliability (airplane, satellite, launcher, medical, etc). Thus, an evaluation of the sensitivity of the component technology is necessary to predict the reliability of a system. In atmospheric environment, the SEU sensitivity is mainly caused by the secondary ions resulting from the nuclear reactions between the neutrons and the atoms of the component. In space environment, the protons with strong energies induce the same effects as the atmospheric neutrons. In our work, a new code of prediction of the rate of SEU has been developed (MC-DASIE) in order to quantify the sensitivity for a given environment and to explore the mechanisms of failures according to technology. This code makes it possible to study various technologies of memories SRAM (Bulk and SOI) in neutron and proton environment between 1 MeV and 1 GeV. Thus, MC-DASIE was used with experiment data to study the effect of integration on the sensitivity of the memories in terrestrial environment, a comparison between the neutron and proton irradiations and the influence of the modeling of the target component on the calculation of the rate of SEU. (author)

  9. Accurate quantum calculations of the reaction rates for H/D+ CH4

    NARCIS (Netherlands)

    Harrevelt, R. van; Nyman, G.; Manthe, U.

    2007-01-01

    In previous work [T. Wu, H. J. Werner, and U. Manthe, Science 306, 2227 (2004)], accurate quantum reaction rate calculations of the rate constant for the H+CH4 -> CH3+H-2 reaction have been presented. Both the electronic structure calculations and the nuclear dynamics calculations are converged with

  10. The calculation of coolant leak rate through the cracks using RELAP5 code

    International Nuclear Information System (INIS)

    Krungeleviciute, V.; Kaliatka, A.

    2001-01-01

    For reason to choose method of leak detection first of all it is necessary to perform evaluating thermal-hydraulic calculations. These calculations allow to determine flow rate of discharged coolant. For coolant leak rate calculations through possible cracks in Ignalina NPP pipes SQUIRT and RELAP5 thermal-hydraulic codes were used. SQUIRT is well known as computer program that predicts the leakage for cracked pipes in NPP. As this code calculates only water (at subcooled or saturated conditions) leak rate, RELAP5 code model, that calculates water and steam leak rate, was created. For model validation comparison of SQUIRT, RELAP5 and experimental results was performed. Analysis shows RELAP5 code model suitability for calculations of leak through through-wall cracks in pipes. (author)

  11. Single Event Upset Energy Dependence In a Buck-Converter Power Supply Design

    CERN Document Server

    Drake, G; The ATLAS collaboration; De Lurgio, P; Stanek, R; Mellado, B; Gopalakrishnan, A; Mahadik, S; Reed, R; Senthilkumaran, A

    2012-01-01

    We present a study of Single Event Upsets performed on a commercial pulse-width modulator controller chip that we are using for a switching power supply design for the Atlas Tile Calorimeter at the LHC. We performed tests to study the probability of an SEU occurring as a function of incident particle (hadron) energy. We compare the results with prediction from theory. We discuss the performance of the circuit, and perform an analysis using Bendel parameters. We also present a solution that we found using external circuitry that eliminates the effect.

  12. Three-dimensional simulation of charge collection and multiple-bit upset in Si devices

    International Nuclear Information System (INIS)

    Dodd, P.E.; Sexton, F.W.; Winokur, P.S.

    1994-01-01

    In this paper, three-dimensional numerical simulation is used to explore the basic charge-collection mechanisms in silicon n + /p diodes. For diodes on lightly-doped substrates ( 15 cm -3 ) struck by a 100-MeV Fe ion, the funneling effect is very strong and essentially all collection is by funnel-assisted drift. This drift collection may occur as late as several nanoseconds after the strike, later than is usually associated with drift collection. For moderately-doped substrates (∼1 x 10 16 cm -3 ) and epitaxial structures grown on heavily-doped substrates, the funnel effect is weaker and drift and diffusion are of more equal importance. For 5-MeV He (α-particle) strikes with low-density charge tracks, the charge-collection transient exhibits both drift and diffusion regimes regardless of the substrate doping. Simulations of diodes with passive external loads indicate that while the current response is altered considerably by the load, total collected charge is not greatly affected for the simple resistive loads studied. Three-dimensional mixed-mode simulation is performed to investigate charge-collection behavior and upset mechanisms in complete CMOS SRAM cells. Simulations of double SRAM cell structures indicate that only collection by diffusion from ''between-node'' strikes is capable of producing multiple-bit upsets in the simulated technology. Limitations of the simulations, specifically carrier-carrier scattering models and large concentration gradients, are also discussed

  13. Implementation of Online Promethee Method for Poor Family Change Rate Calculation

    Directory of Open Access Journals (Sweden)

    Lukito Aji Dhady

    2018-01-01

    Full Text Available This research has been done online calculation of the rate of poor family change rate by using Preference Ranking Method of Organization Of Enrichment Evaluation (PROMETHEE .This system is very useful to monitor poverty in a region as well as for administrative services related to poverty rate. The system consists of computer clients and servers connected via the internet network. Poor family residence data obtained from the government. In addition, survey data are inputted through the client computer in each administrative village and also 23 criteria of input in accordance with the established government. The PROMETHEE method is used to evaluate the value of poverty and its weight is used to determine poverty status. PROMETHEE output can also be used to rank the poverty of the registered population of the server based on the netflow value. The poverty rate is calculated based on the current poverty rate compared to the previous poverty rate. The rate results can be viewed online and real time on the server through numbers and graphs. From the test results can be seen that the system can classify poverty status, calculate the poverty rate change rate and can determine the value and poverty ranking of each population.

  14. Implementation of Online Promethee Method for Poor Family Change Rate Calculation

    Science.gov (United States)

    Aji, Dhady Lukito; Suryono; Widodo, Catur Edi

    2018-02-01

    This research has been done online calculation of the rate of poor family change rate by using Preference Ranking Method of Organization Of Enrichment Evaluation (PROMETHEE) .This system is very useful to monitor poverty in a region as well as for administrative services related to poverty rate. The system consists of computer clients and servers connected via the internet network. Poor family residence data obtained from the government. In addition, survey data are inputted through the client computer in each administrative village and also 23 criteria of input in accordance with the established government. The PROMETHEE method is used to evaluate the value of poverty and its weight is used to determine poverty status. PROMETHEE output can also be used to rank the poverty of the registered population of the server based on the netflow value. The poverty rate is calculated based on the current poverty rate compared to the previous poverty rate. The rate results can be viewed online and real time on the server through numbers and graphs. From the test results can be seen that the system can classify poverty status, calculate the poverty rate change rate and can determine the value and poverty ranking of each population.

  15. Characterization of System Level Single Event Upset (SEU) Responses using SEU Data, Classical Reliability Models, and Space Environment Data

    Science.gov (United States)

    Berg, Melanie; Label, Kenneth; Campola, Michael; Xapsos, Michael

    2017-01-01

    We propose a method for the application of single event upset (SEU) data towards the analysis of complex systems using transformed reliability models (from the time domain to the particle fluence domain) and space environment data.

  16. Application of RADSAFE to Model Single Event Upset Response of a 0.25 micron CMOS SRAM

    Science.gov (United States)

    Warren, Kevin M.; Weller, Robert A.; Sierawski, Brian; Reed, Robert A.; Mendenhall, Marcus H.; Schrimpf, Ronald D.; Massengill, Lloyd; Porter, Mark; Wilkerson, Jeff; LaBel, Kenneth A.; hide

    2006-01-01

    The RADSAFE simulation framework is described and applied to model Single Event Upsets (SEU) in a 0.25 micron CMOS 4Mbit Static Random Access Memory (SRAM). For this circuit, the RADSAFE approach produces trends similar to those expected from classical models, but more closely represents the physical mechanisms responsible for SEU in the SRAM circuit.

  17. Impact of temperature on single event upset measurement by heavy ions in SRAM devices

    International Nuclear Information System (INIS)

    Liu Tianqi; Geng Chao; Zhang Zhangang; Gu Song; Tong Teng; Xi Kai; Hou Mingdong; Liu Jie; Zhao Fazhan; Liu Gang; Han Zhengsheng

    2014-01-01

    The temperature dependence of single event upset (SEU) measurement both in commercial bulk and silicon on insulator (SOI) static random access memories (SRAMs) has been investigated by experiment in the Heavy Ion Research Facility in Lanzhou (HIRFL). For commercial bulk SRAM, the SEU cross section measured by 12 C ions is very sensitive to the temperature. The temperature test of SEU in SOI SRAM was conducted by 209 Bi and 12 C ions, respectively, and the SEU cross sections display a remarkable growth with the elevated temperature for 12 C ions but keep constant for 209 Bi ions. The impact of temperature on SEU measurement was analyzed by Monte Carlo simulation. It is revealed that the SEU cross section is significantly affected by the temperature around the threshold linear energy transfer of SEU occurrence. As the SEU occurrence approaches saturation, the SEU cross section gradually exhibits less temperature dependency. Based on this result, the experimental data measured in HIRFL was analyzed, and then a reasonable method of predicting the on-orbit SEU rate was proposed. (semiconductor devices)

  18. RCS Leak Rate Calculation with High Order Least Squares Method

    International Nuclear Information System (INIS)

    Lee, Jeong Hun; Kang, Young Kyu; Kim, Yang Ki

    2010-01-01

    As a part of action items for Application of Leak before Break(LBB), RCS Leak Rate Calculation Program is upgraded in Kori unit 3 and 4. For real time monitoring of operators, periodic calculation is needed and corresponding noise reduction scheme is used. This kind of study was issued in Korea, so there have upgraded and used real time RCS Leak Rate Calculation Program in UCN unit 3 and 4 and YGN unit 1 and 2. For reduction of the noise in signals, Linear Regression Method was used in those programs. Linear Regression Method is powerful method for noise reduction. But the system is not static with some alternative flow paths and this makes mixed trend patterns of input signal values. In this condition, the trend of signal and average of Linear Regression are not entirely same pattern. In this study, high order Least squares Method is used to follow the trend of signal and the order of calculation is rearranged. The result of calculation makes reasonable trend and the procedure is physically consistence

  19. Single event upset and charge collection measurements using high energy protons and neutrons

    International Nuclear Information System (INIS)

    Normand, E.; Oberg, D.L.; Wert, J.L.; Ness, J.D.; Majewski, P.P.; Wender, S.; Gavron, A.

    1994-01-01

    RAMs, microcontrollers and surface barrier detectors were exposed to beams of high energy protons and neutrons to measure the induced number of upsets as well as energy deposition. The WNR facility at Los Alamos provided a neutron spectrum similar to that of the atmospheric neutrons. Its effect on devices was compared to that of protons with energies of 200, 400, 500, and 800 MeV. Measurements indicate that SEU cross sections for 400 MeV protons are similar to those induced by the atmospheric neutron spectrum

  20. Relativistic QRPA calculation of β-decay rates of r-process nuclei

    International Nuclear Information System (INIS)

    Marketin, T.; Paar, N.; Niksic, T.

    2009-01-01

    The rapid neutron-capture process (r-process) is responsible for the creation of many nuclei heavier than iron. To describe the r-process, precise data is needed on a large number of neutron-rich nuclei, most of which are not experimentally reachable. One crucial parameter in modeling the nucleosynthesis are the half-lives of the nuclei through which the r-process runs. Therefore, it is of great importance to develop a reliable predictive model which can be applied to the decay of exotic nuclei. A fully self-consistent calculation of β-decay rates is presented, based on a microscopic theoretical framework. Nuclear ground state is determined using the Relativistic Hartree-Bogoliubov (RHB) model with density-dependent meson-nucleon coupling constants. Momentum dependent terms are also included to improve the density of single-particle states around the Fermi level via an increase of the effective nucleon mass [1]. Transition rates are calculated within the proton-neutron relativistic quasiparticle RPA using the same interaction that was used in the RHB equations. In this way no additional parameters are introduced in the RPA calculation. Weak interaction rates are calculated using the current-current formalism previously employed in the study of other astrophysically significant weak processes [2,3], which systematically includes the contributions of forbidden transitions. This theoretical framework will be utilized to study the contributions of forbidden transitions to the total decay rate in several mass regions. We will compare the calculated half-lives for several isotopic chains with previous calculations and experimental data and discuss possible improvements to the model.(author)

  1. Calculation of gamma ray exposure rates from uranium ore bodies

    International Nuclear Information System (INIS)

    Thomson, J.E.; Wilson, O.J.

    1980-02-01

    The planning of operations associated with uranium mines often requires that estimates be made of the exposure rates from various ore bodies. A straight-forward method of calculating the exposure rate from an arbitrarily shaped body is presented. Parameters for the calculation are evaluated under the assumption of secular equilibrium of uranium with its daughters and that the uranium is uniformly distributed throughout an average soil mixture. The spectral distribution of the emitted gamma rays and the effect of air attenuation are discussed. Worked examples are given of typical situations encountered in uranium mines

  2. Audit Calculations of LBLOCA for Ulchin Unit 1 and 2 Power Up rate

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Donggu; Huh, Byunggil; Yoo, Seunghunl; Yang, Chaeyong; Seul, Kwangwon [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-05-15

    The KINS-Realistic Evaluation Model (KINS-REM) was developed for the independent audit calculation in 1991, and the code accuracy and statistical method have been improved. To support the licensing review and to confirm the validity of licensee's calculation, regulatory auditing calculations have been also conducted. Currently, the modification of Ulchin 1 and 2 operating license for 4.5% power up rate is under review. In this study, the regulatory audit calculation for LBLOCA of Ulchin Unit 1 and 2 with 4.5% power up rate was performed by applying KINS-REM. In this study, the regulatory audit calculation for LBLOCA of Ulchin Unit 1 and 2 with 4.5% power up rate was performed by applying KINS-REM. It is confirmed that the analysis results of LBLOCA for Ulchin 1 and 2 power up rate meets the PCT acceptance criteria.

  3. Experiences with leak rate calculations methods for LBB application

    Energy Technology Data Exchange (ETDEWEB)

    Grebner, H.; Kastner, W.; Hoefler, A.; Maussner, G. [and others

    1997-04-01

    In this paper, three leak rate computer programs for the application of leak before break analysis are described and compared. The programs are compared to each other and to results of an HDR Reactor experiment and two real crack cases. The programs analyzed are PIPELEAK, FLORA, and PICEP. Generally, the different leak rate models are in agreement. To obtain reasonable agreement between measured and calculated leak rates, it was necessary to also use data from detailed crack investigations.

  4. Experiences with leak rate calculations methods for LBB application

    International Nuclear Information System (INIS)

    Grebner, H.; Kastner, W.; Hoefler, A.; Maussner, G.

    1997-01-01

    In this paper, three leak rate computer programs for the application of leak before break analysis are described and compared. The programs are compared to each other and to results of an HDR Reactor experiment and two real crack cases. The programs analyzed are PIPELEAK, FLORA, and PICEP. Generally, the different leak rate models are in agreement. To obtain reasonable agreement between measured and calculated leak rates, it was necessary to also use data from detailed crack investigations

  5. Single Event Upset Analysis: On-orbit performance of the Alpha Magnetic Spectrometer Digital Signal Processor Memory aboard the International Space Station

    Science.gov (United States)

    Li, Jiaqiang; Choutko, Vitaly; Xiao, Liyi

    2018-03-01

    Based on the collection of error data from the Alpha Magnetic Spectrometer (AMS) Digital Signal Processors (DSP), on-orbit Single Event Upsets (SEUs) of the DSP program memory are analyzed. The daily error distribution and time intervals between errors are calculated to evaluate the reliability of the system. The particle density distribution of International Space Station (ISS) orbit is presented and the effects from the South Atlantic Anomaly (SAA) and the geomagnetic poles are analyzed. The impact of solar events on the DSP program memory is carried out combining data analysis and Monte Carlo simulation (MC). From the analysis and simulation results, it is concluded that the area corresponding to the SAA is the main source of errors on the ISS orbit. Solar events can also cause errors on DSP program memory, but the effect depends on the on-orbit particle density.

  6. Dose Rate Calculations for Rotary Mode Core Sampling Exhauster

    CERN Document Server

    Foust, D J

    2000-01-01

    This document provides the calculated estimated dose rates for three external locations on the Rotary Mode Core Sampling (RMCS) exhauster HEPA filter housing, per the request of Characterization Field Engineering.

  7. Dose Rate Calculations for Rotary Mode Core Sampling Exhauster

    International Nuclear Information System (INIS)

    FOUST, D.J.

    2000-01-01

    This document provides the calculated estimated dose rates for three external locations on the Rotary Mode Core Sampling (RMCS) exhauster HEPA filter housing, per the request of Characterization Field Engineering

  8. An SEU rate prediction method for microprocessors of space applications

    International Nuclear Information System (INIS)

    Gao Jie; Li Qiang

    2012-01-01

    In this article,the relationship between static SEU (Single Event Upset) rate and dynamic SEU rate in microprocessors for satellites is studied by using process duty cycle concept and fault injection technique. The results are compared to in-orbit flight monitoring data. The results show that dynamic SEU rate by using process duty cycle can estimate in-orbit SEU rate of microprocessor reasonable; and the fault injection technique is a workable method to estimate SEU rate. (authors)

  9. Basic study for plastic deformation of rapidly quenched Nd-Fe-Co-Ga-B magnets at elevated temperature

    International Nuclear Information System (INIS)

    Akayama, M.; Tanigawa, S.; Tokunaga, M.

    1990-01-01

    In order to optimize hot working conditions of rapidly quenched Nd-Fe-C-Ga-B magnets, the behavior of plastic deformation at elevated temperatures has been studied. Compressive and tensile tests were performed with various hot working parameters. Computer simulation of the die upsetting process was performed by rigid plastic FEM calculation. It was found that, to suppress the occurrence of peripheral cracks and improve magnetic properties, low strain rates are necessary. Computer calculation of the distribution of stress can explain the mechanism of peripheral crack initiation in the die upsetting process

  10. Analyzing Test-As-You-Fly Single Event Upset (SEU) Responses using SEU Data, Classical Reliability Models, and Space Environment Data

    Science.gov (United States)

    Berg, Melanie; Label, Kenneth; Campola, Michael; Xapsos, Michael

    2017-01-01

    We propose a method for the application of single event upset (SEU) data towards the analysis of complex systems using transformed reliability models (from the time domain to the particle fluence domain) and space environment data.

  11. Single event upset threshold estimation based on local laser irradiation

    International Nuclear Information System (INIS)

    Chumakov, A.I.; Egorov, A.N.; Mavritsky, O.B.; Yanenko, A.V.

    1999-01-01

    An approach for estimation of ion-induced SEU threshold based on local laser irradiation is presented. Comparative experiment and software simulation research were performed at various pulse duration and spot size. Correlation of single event threshold LET to upset threshold laser energy under local irradiation was found. The computer analysis of local laser irradiation of IC structures was developed for SEU threshold LET estimation. The correlation of local laser threshold energy with SEU threshold LET was shown. Two estimation techniques were suggested. The first one is based on the determination of local laser threshold dose taking into account the relation of sensitive area to local irradiated area. The second technique uses the photocurrent peak value instead of this relation. The agreement between the predicted and experimental results demonstrates the applicability of this approach. (authors)

  12. Rate maximum calculation of Dpa in CNA-II pressure vessel

    International Nuclear Information System (INIS)

    Mascitti, J. A

    2012-01-01

    The maximum dpa rate was calculated for the reactor in the following state: fresh fuel, no Xenon, a Boron concentration of 15.3 ppm, critical state, its control rods in the criticality position, hot, at full power (2160 MW). It was determined that the maximum dpa rate under such conditions is 3.54(2)x10 12 s -1 and it is located in the positions corresponding to θ=210 o in the azimuthal direction, and z=20 cm and -60 cm respectively in the axial direction, considering the calculation mesh centered at half height of the fuel element (FE) active length. The dpa rate spectrum was determined as well as the contribution to it for 4 energy groups: a thermal group, two epithermal groups and a fast one. The maximum dpa rate considering the photo-neutrons production from (γ, n) reaction in the heavy water of coolant and moderator was 3.93(4)x10 12 s -1 that is 11% greater than the obtained without photo-neutrons. This verified significant difference between both cases, suggest that photo-neutrons in large heavy water reactors such as CNA-II should not be ignored. The maximum DPA rate in the first mm of the reactor pressure vessel was calculated too and it was obtained a value of 4.22(6)x10 12 s -1 . It should be added that the calculation was carried out with the reactor complete accurate model, with no approximations in spatial or energy variables. Each value has, between parentheses, a percentage relative error representing the statistical uncertainty due to the probabilistic Monte Carlo method used to estimate it. More representative values may be obtained with this method if equilibrium burn-up distribution is used (author)

  13. Calculation of the gamma-dose rate from a continuously emitted plume

    International Nuclear Information System (INIS)

    Huebschmann, W.; Papadopoulos, D.

    1975-06-01

    A computer model is presented which calculates the long term gamma dose rate caused by the radioactive off-gas continuously emitted from a stack. The statistical distribution of the wind direction and velocity and of the stability categories is taken into account. The emitted activity, distributed in the atmosphere according to this statistics, is assumed to be concentrated at the mesh points of a three-dimensional grid. The grid spacing and the integration limits determine the accuracy as well as the computer time needed. When calculating the dose rate in a given wind direction, the contribution of the activity emitted into the neighbouring sectors is evaluated. This influence is demonstrated in the results, which are calculated with a error below 3% and compared to the dose rate distribution curves of the submersion model and the model developed by K.J. Vogt. (orig.) [de

  14. Scientific periodical publications rating's calculation and analysis

    Directory of Open Access Journals (Sweden)

    B. E. Nikitin

    2017-01-01

    Full Text Available The article considers the constructing problem of the food industry journals aggregate ratings. The streamlines of the seventeen magazines on four bibliometric indexes (SCIENCE INDEX, five-year impact factor RISC given the translated version without self-citations, h-index over 10 years and Herfindahl index, which are used in the scientific electronic library elibrary.ru was used as initial data. The statement of the problem refers to multi-criteria decision-making problems. Ranking the journals in these indexes are different from each other because bibliometric indicators account different aspects of the journals. The classical approach to thisproblems solution is based on generalized criterion building in the form of an additive convolution. However, this approach requires adherence to a number of regular conditions that may not always be performed when the practical problems solution. The reductionspossibility of the considered formulation in the form of multi-criteria decision-making tasks to the problem of collective choice. The aggregated ratings of the reporting journals are calculated by using the three social choice rules – Board procedure, Copeland procedures and Kemeny median heuristic procedures. On the basis of Spearman's rank correlation determined the quantitative evaluation of the degree of intimacy built in magazines. In particular, calculated on the basis of procedure, Board and Kemeny median aggregate ratings reporting in the logs coincided. The results showed that the constructed ordering of journals on the basis of social choice rules are in good agreement with the scientific electronic library (eLIBRARY bibliometric indicators.

  15. Biased Brownian dynamics for rate constant calculation.

    OpenAIRE

    Zou, G; Skeel, R D; Subramaniam, S

    2000-01-01

    An enhanced sampling method-biased Brownian dynamics-is developed for the calculation of diffusion-limited biomolecular association reaction rates with high energy or entropy barriers. Biased Brownian dynamics introduces a biasing force in addition to the electrostatic force between the reactants, and it associates a probability weight with each trajectory. A simulation loses weight when movement is along the biasing force and gains weight when movement is against the biasing force. The sampl...

  16. HLW disposal by fission reactors; calculation of trans-mutation rate and recycle

    International Nuclear Information System (INIS)

    Mulyanto

    1997-01-01

    Transmutation of MA (Minor actinide) and LLFPS (long-lived fission products) into stable nuclide or short-lived isotopes by fission reactors seem to become an alternative technology for HLW disposal. in this study, transmutation rate and recycle calculation were developed in order to evaluate transmutation characteristics of MA and LLFPs in the fission reactors. inventory of MA and LLFPs in the transmutation reactors were determined by solving of criticality equation with 1-D cylindrical geometry of multigroup diffusion equations at the beginning of cycle (BOC). transmutation rate and burn-up was determined by solving of depletion equation. inventory of MA and LLFPs was calculated for 40 years recycle. From this study, it was concluded that characteristics of MA and LLFPs in the transmutation reactors can be evaluated by recycle calculation. by calculation of transmutation rate, performance of fission reactor for transmutation of MA or LLFPs can be discussed

  17. An Approach for the Assessment of System Upset Resilience

    Science.gov (United States)

    Torres-Pomales, Wilfredo

    2013-01-01

    This report describes an approach for the assessment of upset resilience that is applicable to systems in general, including safety-critical, real-time systems. For this work, resilience is defined as the ability to preserve and restore service availability and integrity under stated conditions of configuration, functional inputs and environmental conditions. To enable a quantitative approach, we define novel system service degradation metrics and propose a new mathematical definition of resilience. These behavioral-level metrics are based on the fundamental service classification criteria of correctness, detectability, symmetry and persistence. This approach consists of a Monte-Carlo-based stimulus injection experiment, on a physical implementation or an error-propagation model of a system, to generate a system response set that can be characterized in terms of dimensional error metrics and integrated to form an overall measure of resilience. We expect this approach to be helpful in gaining insight into the error containment and repair capabilities of systems for a wide range of conditions.

  18. Relativistic QRPA Calculation of β-Decay Rates of r-process Nuclei

    International Nuclear Information System (INIS)

    Marketin, T.; Paar, N.; Niksic, T.; Vretenar, D.; Ring, P.

    2009-01-01

    A systematic, fully self-consistent calculation of β-decay rates is presented, based on a microscopic theoretical framework. Analysis is performed on a large number of nuclei from the valley of β stability towards the neutron drip-line. Nuclear ground state is determined using the Relativistic Hartree-Bogoliubov (RHB) model with density-dependent meson-nucleon coupling constants. Transition rates are calculated within the proton-neutron relativistic quasiparticle RPA (pn-RQRPA) using the same interaction that was used in the RHB equations.

  19. Calculating stocking rates for game ranches: substitution ratios for ...

    African Journals Online (AJOL)

    Calculating stocking rates for game ranches: substitution ratios for use in the Mopani ... Reports on a study conducted to quantify the overlap in ungulate resource-use on a game ranch, and to demonstrate how ... AJOL African Journals Online.

  20. Comparison of leak opening and leak rate calculations to HDR experimental results

    International Nuclear Information System (INIS)

    Grebner, H.; Hoefler, A.; Hunger, H.

    1993-01-01

    During the last years a number of calculations of leak opening and leak rate for through cracks in piping components have been performed. Analyses are pre- or mostly post-calculations to experiments performed at the HDR facility under PWR operating conditions. Piping components under consideration were small diameter straight pipes with circumferential cracks, pipe bends with longitudinal or circumferential cracks and pipe branches with weldment cracks. The components were loaded by internal pressure and opening as well as closing bending moment. The finite element method and two-phase flow leak rate programs were used for the calculations. Results of the analyses are presented as J-integral values, crack opening displacements and areas and leak rates as well as comparisons to the experimental results

  1. Calculation of radiation dose rate arisen from radionuclide contained in building materials

    International Nuclear Information System (INIS)

    Lai Tien Thinh; Nguyen Hao Quang

    2008-01-01

    This paper presents some results that we used MCNP5 program to calculate radiation dose rate arisen from radionuclide in building materials. Since then, the limits of radionuclide content in building materials are discussed. The calculation results by MCNP are compared with those calculated by analytical method. (author)

  2. Evaluation of dose equivalent rate distribution in JCO critical accident by radiation transport calculation

    CERN Document Server

    Sakamoto, Y

    2002-01-01

    In the prevention of nuclear disaster, there needs the information on the dose equivalent rate distribution inside and outside the site, and energy spectra. The three dimensional radiation transport calculation code is a useful tool for the site specific detailed analysis with the consideration of facility structures. It is important in the prediction of individual doses in the future countermeasure that the reliability of the evaluation methods of dose equivalent rate distribution and energy spectra by using of Monte Carlo radiation transport calculation code, and the factors which influence the dose equivalent rate distribution outside the site are confirmed. The reliability of radiation transport calculation code and the influence factors of dose equivalent rate distribution were examined through the analyses of critical accident at JCO's uranium processing plant occurred on September 30, 1999. The radiation transport calculations including the burn-up calculations were done by using of the structural info...

  3. Crying without a cause and being easily upset in two-year-olds: heritability and predictive power of behavioral problems

    NARCIS (Netherlands)

    Groen-Blokhuis, Maria M.; Middeldorp, Christel M.; van Beijsterveldt, Catharina E.; Boomsma, Dorret I.

    2011-01-01

    In order to estimate the influence of genetic and environmental factors on 'crying without a cause' and 'being easily upset' in 2-year-old children, a large twin study was carried out. Prospective data were available for ~18,000 2-year-old twin pairs from the Netherlands Twin Register. A bivariate

  4. Modeling for Dose Rate Calculation of the External Exposure to Gamma Emitters in Soil

    International Nuclear Information System (INIS)

    Allam, K. A.; El-Mongy, S. A.; El-Tahawy, M. S.; Mohsen, M. A.

    2004-01-01

    Based on the model proposed and developed in Ph.D thesis of the first author of this work, the dose rate conversion factors (absorbed dose rate in air per specific activity of soil in nGy.hr - 1 per Bq.kg - 1) are calculated 1 m above the ground for photon emitters of natural radionuclides uniformly distributed in the soil. This new and simple dose rate calculation software was used for calculation of the dose rate in air 1 m above the ground. Then the results were compared with those obtained by five different groups. Although the developed model is extremely simple, the obtained results of calculations, based on this model, show excellent agreement with those obtained by the above-mentioned models specially that one adopted by UNSCEAR. (authors)

  5. Crying Without a Cause and Being Easily Upset in Two-Year-Olds: Heritability and Predictive Power of Behavioral Problems

    NARCIS (Netherlands)

    Groen-Blokhuis, M.M.; Middeldorp, C.M.; van Beijsterveldt, C.E.M.; Boomsma, D.I.

    2011-01-01

    In order to estimate the influence of genetic and environmental factors on 'crying without a cause' and 'being easily upset' in 2-year-old children, a large twin study was carried out. Prospective data were available for ∼18,000 2-year-old twin pairs from the Netherlands Twin Register. A bivariate

  6. A New Method to Calculate Internal Rate of Return

    Directory of Open Access Journals (Sweden)

    azadeh zandi

    2015-09-01

    Full Text Available A number of methods have been developed to choose the best capital investment projects such as net present value, internal rate of return and etc. Internal rate of return method is probably the most popular method among managers and investors. But despite the popularity there are serious drawbacks and limitations in this method. After decades of efforts made by economists and experts to improve the method and its shortcomings, Magni in 2010 has revealed a new approach that can solves the most of internal rate of return method problems. This paper present a new method which is originated from Magni’s approach but has much more simple calculations and can resolve all the drawbacks of internal rate of return method.

  7. Semiclassical Calculation of Reaction Rate Constants for Homolytical Dissociations

    Science.gov (United States)

    Cardelino, Beatriz H.

    2002-01-01

    There is growing interest in extending organometallic chemical vapor deposition (OMCVD) to III-V materials that exhibit large thermal decomposition at their optimum growth temperature, such as indium nitride. The group III nitrides are candidate materials for light-emitting diodes and semiconductor lasers operating into the blue and ultraviolet regions. To overcome decomposition of the deposited compound, the reaction must be conducted at high pressures, which causes problems of uniformity. Microgravity may provide the venue for maintaining conditions of laminar flow under high pressure. Since the selection of optimized parameters becomes crucial when performing experiments in microgravity, efforts are presently geared to the development of computational OMCVD models that will couple the reactor fluid dynamics with its chemical kinetics. In the present study, we developed a method to calculate reaction rate constants for the homolytic dissociation of III-V compounds for modeling OMCVD. The method is validated by comparing calculations with experimental reaction rate constants.

  8. Calculation method for gamma dose rates from Gaussian puffs

    Energy Technology Data Exchange (ETDEWEB)

    Thykier-Nielsen, S; Deme, S; Lang, E

    1995-06-01

    The Lagrangian puff models are widely used for calculation of the dispersion of releases to the atmosphere. Basic output from such models is concentration of material in the air and on the ground. The most simple method for calculation of the gamma dose from the concentration of airborne activity is based on the semi-infinite cloud model. This method is however only applicable for puffs with large dispersion parameters, i.e. for receptors far away from the release point. The exact calculation of the cloud dose using volume integral requires large computer time usually exceeding what is available for real time calculations. The volume integral for gamma doses could be approximated by using the semi-infinite cloud model combined with correction factors. This type of calculation procedure is very fast, but usually the accuracy is poor because only a few of the relevant parameters are considered. A multi-parameter method for calculation of gamma doses is described here. This method uses precalculated values of the gamma dose rates as a function of E{sub {gamma}}, {sigma}{sub y}, the asymmetry factor - {sigma}{sub y}/{sigma}{sub z}, the height of puff center - H and the distance from puff center R{sub xy}. To accelerate the calculations the release energy, for each significant radionuclide in each energy group, has been calculated and tabulated. Based on the precalculated values and suitable interpolation procedure the calculation of gamma doses needs only short computing time and it is almost independent of the number of radionuclides considered. (au) 2 tabs., 15 ills., 12 refs.

  9. Calculation method for gamma dose rates from Gaussian puffs

    International Nuclear Information System (INIS)

    Thykier-Nielsen, S.; Deme, S.; Lang, E.

    1995-06-01

    The Lagrangian puff models are widely used for calculation of the dispersion of releases to the atmosphere. Basic output from such models is concentration of material in the air and on the ground. The most simple method for calculation of the gamma dose from the concentration of airborne activity is based on the semi-infinite cloud model. This method is however only applicable for puffs with large dispersion parameters, i.e. for receptors far away from the release point. The exact calculation of the cloud dose using volume integral requires large computer time usually exceeding what is available for real time calculations. The volume integral for gamma doses could be approximated by using the semi-infinite cloud model combined with correction factors. This type of calculation procedure is very fast, but usually the accuracy is poor because only a few of the relevant parameters are considered. A multi-parameter method for calculation of gamma doses is described here. This method uses precalculated values of the gamma dose rates as a function of E γ , σ y , the asymmetry factor - σ y /σ z , the height of puff center - H and the distance from puff center R xy . To accelerate the calculations the release energy, for each significant radionuclide in each energy group, has been calculated and tabulated. Based on the precalculated values and suitable interpolation procedure the calculation of gamma doses needs only short computing time and it is almost independent of the number of radionuclides considered. (au) 2 tabs., 15 ills., 12 refs

  10. Benchmark calculations of thermal reaction rates. I - Quantal scattering theory

    Science.gov (United States)

    Chatfield, David C.; Truhlar, Donald G.; Schwenke, David W.

    1991-01-01

    The thermal rate coefficient for the prototype reaction H + H2 yields H2 + H with zero total angular momentum is calculated by summing, averaging, and numerically integrating state-to-state reaction probabilities calculated by time-independent quantum-mechanical scattering theory. The results are very carefully converged with respect to all numerical parameters in order to provide high-precision benchmark results for confirming the accuracy of new methods and testing their efficiency.

  11. Textural states of a hot-worked MA2-1 magnesium alloy

    Science.gov (United States)

    Serebryany, V. N.; Kochubei, A. Ya.; Kurtasov, S. F.; Mel'Nikov, K. E.

    2007-02-01

    Quantitative texture analysis is used to study texture formation in an MA2-1 magnesium alloy subjected to axisymmetric upsetting at temperatures of 250-450°C and strain rates of 10-4-100 -1. The deformed structure is examined by optical microscopy, and the results obtained are used to plot the structural-state diagram of the alloy after 50% upsetting. The experimental textures are compared with the textures calculated in terms of a thermoactivation model.

  12. Calculation of dose-rate conversion factors for external exposure to photons and electrons

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1978-01-01

    Methods are presented for the calculation of dose-rate conversion factors for external exposure to photon and electron radiation from radioactive decay. A dose-rate conversion factor is defined as the dose-equivalent rate per unit radionuclide concentration. Exposure modes considered are immersion in contaminated air, immersion in contaminated water, and irradiation from a contaminated ground surface. For each radiation type and exposure mode, dose-rate conversion factors are derived for tissue-equivalent material at the body surface of an exposed individual. In addition, photon dose-rate conversion factors are estimated for 22 body organs. The calculations are based on the assumption that the exposure medium is infinite in extent and that the radionuclide concentration is uniform. The dose-rate conversion factors for immersion in contaminated air and water then follow from the requirement that all of the energy emitted in the radioactive decay is absorbed in the infinite medium. Dose-rate conversion factors for ground-surface exposure are calculated at a reference location above a smooth, infinite plane using the point-kernel integration method and known specific absorbed fractions for photons and electrons in air

  13. Low-energy neutron-induced single-event upsets in static random access memory

    International Nuclear Information System (INIS)

    Guo Xiaoqiang; Guo Hongxia; Wang Guizhen; Ling Dongsheng; Chen Wei; Bai Xiaoyan; Yang Shanchao; Liu Yan

    2009-01-01

    The visual analysis method of data process was provided for neutron-induced single-event upset(SEU) in static random access memory(SRAM). The SEU effects of six CMOS SRAMs with different feature size(from 0.13 μm to 1.50 μm) were studied. The SEU experiments were performed using the neutron radiation environment at Xi'an pulsed reactor. And the dependence of low-energy neutron-induced SEU cross section on SRAM's feature size was given. The results indicate that the decreased critical charge is the dominant factor for the increase of single event effect sensitivity of SRAM devices with decreased feature size. Small-sized SRAM devices are more sensitive than large-sized ones to single event effect induced by low-energy neutrons. (authors)

  14. Calculation method for gamma-dose rates from spherical puffs

    International Nuclear Information System (INIS)

    Thykier-Nielsen, S.; Deme, S.; Lang, E.

    1993-05-01

    The Lagrangian puff-models are widely used for calculation of the dispersion of atmospheric releases. Basic output from such models are concentrations of material in the air and on the ground. The most simple method for calculation of the gamma dose from the concentration of airborne activity is based on semi-infinite cloud model. This method is however only applicable for points far away from the release point. The exact calculation of the cloud dose using the volume integral requires significant computer time. The volume integral for the gamma dose could be approximated by using the semi-infinite cloud model combined with correction factors. This type of calculation procedure is very fast, but usually the accuracy is poor due to the fact that the same correction factors are used for all isotopes. The authors describe a more elaborate correction method. This method uses precalculated values of the gamma-dose rate as a function of the puff dispersion parameter (δ p ) and the distance from the puff centre for four energy groups. The release of energy for each radionuclide in each energy group has been calculated and tabulated. Based on these tables and a suitable interpolation procedure the calculation of gamma doses takes very short time and is almost independent of the number of radionuclides. (au) (7 tabs., 7 ills., 12 refs.)

  15. Characterization of System on a Chip (SoC) Single Event Upset (SEU) Responses Using SEU Data, Classical Reliability Models, and Space Environment Data

    Science.gov (United States)

    Berg, Melanie; Label, Kenneth; Campola, Michael; Xapsos, Michael

    2017-01-01

    We propose a method for the application of single event upset (SEU) data towards the analysis of complex systems using transformed reliability models (from the time domain to the particle fluence domain) and space environment data.

  16. A calculation of the surface recombination rate constant for hydrogen isotopes on metals

    International Nuclear Information System (INIS)

    Baskes, M.J.

    1980-01-01

    The surface recombination rate constant for hydrogen isotopes on a metal has been calculated using a simple model whose parameters may be determined by direct experimental measurements. Using the experimental values for hydrogen diffusivity, solubility, and sticking coefficient at zero surface coverage a reasonable prediction of the surface recombination constant may be made. The calculated recombination constant is in excellent agreement with experiment for bcc iron. A heuristic argument is developed which, along with the rate constant calculation, shows that surface recombination is important in those metals in which hydrogen has an exothermic heat of solution. (orig.)

  17. Calculation of nuclear-spin-relaxation rate for spin-polarized atomic hydrogen

    International Nuclear Information System (INIS)

    Ahn, R.M.C.; Eijnde, J.P.H.W.V.; Verhaar, B.J.

    1983-01-01

    Approximations introduced in previous calculations of spin relaxation for spin-polarized atomic hydrogen are investigated by carrying out a more exact coupled-channel calculation. With the exception of the high-temperature approximation, the approximations turn out to be justified up to the 10 -3 level of accuracy. It is shown that at the lowest temperatures for which experimental data are available, the high-temperature limit underestimates relaxation rates by a factor of up to 2. For a comparison with experimental data it is also of interest to pay attention to the expression for the atomic hydrogen relaxation rates in terms of transition amplitudes for two-particle collisions. Discrepancies by a factor of 2 among previous derivations of relaxation rates are pointed out. To shed light on these discrepancies we present two alternative derivations in which special attention is paid to identical-particle aspects. Comparing with experiment, we find our theoretical volume relaxation rate to be in better agreement with measured values than that obtained by other groups. The theoretical surface relaxation rate, however, still shows a discrepancy with experiment by a factor of order 50

  18. Transport calculations of. gamma. -ray flux density and dose rate about implantable californium-252 sources

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, A; Lin, B I [Cincinnati Univ., Ohio (USA). Dept. of Chemical and Nuclear Engineering; Windham, J P; Kereiakes, J G

    1976-07-01

    ..gamma.. flux density and dose rate distributions have been calculated about implantable californium-252 sources for an infinite tissue medium. Point source flux densities as a function of energy and position were obtained from a discrete-ordinates calculation, and the flux densities were multiplied by their corresponding kerma factors and added to obtain point source dose rates. The point dose rates were integrated over the line source to obtain line dose rates. Container attenuation was accounted for by evaluating the point dose rate as a function of platinum thickness. Both primary and secondary flux densities and dose rates are presented. The agreement with an independent Monte Carlo calculation was excellent. The data presented should be useful for the design of new source configurations.

  19. Calculation of radiation dose rates from a spent nuclear fuel shipping cask

    International Nuclear Information System (INIS)

    Chen, S.Y.; Yuan, Y.C.

    1988-01-01

    Radiation doses from a spent nuclear fuel cask are usually from various phases of operations during handling, shipping, and storage of the casks. Assessment of such doses requires knowledge of external radiation dose rates at various locations surrounding a cask. Under current practices, dose rates from gamma photons are usually estimated by means of point- or line-source approaches incorporating the conventional buildup factors. Although such simplified approaches may at times be easy to use, their accuracy has not been verified. For example, those simplified methods have not taken into account influencing factors such as the geometry of the cask and the presence of the ground surface, and the effects of these factors on the calculated dose rates are largely unknown. Moreover, similar empirical equations for buildup factors currently do not exist for neutrons. The objective of this study is to use a more accurate approach in calculating radiation dose rates for both neutrons and gamma photons from a spent fuel cask. The calculation utilizes the more sophisticated transport method and takes into account the geometry of the cask and the presence of the ground surface. The results of a detailed study of dose rates in the near field (within 20 meters) are presented and, for easy application, the cask centerline dose rates are fitted into empirical equations at cask centerline distances up to 2000 meters from the surface of the cask

  20. From laboratory experiments to a geological disposal vault: calculation of used nuclear fuel dissolution rates

    International Nuclear Information System (INIS)

    Sunder, S.; Shoesmith, D.W.; Kolar, M.; Leneveu, D.M.

    1998-01-01

    Calculation of used nuclear fuel dissolution rates in a geological disposal vault requires a knowledge of the redox conditions in the vault. For redox conditions less oxidizing than those causing UO 2 oxidation to the U 3 O 7 , stage, a thermodynamically-based model is appropriate. For more oxidizing redox conditions a kinetic or an electrochemical model is needed to calculate these rates. The redox conditions in a disposal vault will be affected by the radiolysis of groundwater by the ionizing radiation associated with the fuel. Therefore, we have calculated the alpha-, beta- and gamma-dose rates in water in contact with the reference used fuel in the Canadian Nuclear Fuel Waste Management Program (CNFWMP) as a function of cooling time. Also, we have determined dissolution rates of UO 2 fuel as a function of alpha and gamma dose rates from our electrochemical measurements. These room-temperature rates are used to calculate the dissolution rates of used fuel at 100 o C, the highest temperature expected in a container in the CNFWMP, as a function of time since emplacement. It is shown that beta radiolysis of water will be the main cause of oxidation of used CANDU fuel in a failed container. The use of a kinetic or an electrochemical corrosion model, to calculate fuel dissolution rates, is required for a period of ∼1000 a following emplacement of copper containers in the geologic disposal vault envisaged in the CNFWMP. Beyond this time period a thermodynamically-based model adequately predicts the fuel dissolution rates. The results presented in this paper can be adopted to calculate used fuel dissolution rates for other used UO 2 fuels in other waste management programs. (author)

  1. Configuration interaction calculations and excitation rates of X-ray and EUV transitions in sulfurlike manganese

    Energy Technology Data Exchange (ETDEWEB)

    El-Maaref, A.A., E-mail: ahmed.maaref@azhar.edu.eg; Saddeek, Y.B.; Abou halaka, M.M.

    2017-02-15

    Highlights: • Fine-structure calculations of sulfurlike Mn have been performed using configuration interaction technique, CI. • The relativistic effects, Breit-Pauli Hameltonian, have been correlated to the CI calculations. • Excitation rates by electron impact of the Mn X ion have been evaluated up to ionization potential. - Abstract: Fine-structure calculations of energies and transition parameters have been performed using the configuration interaction technique (CI) as implemented in CIV3 code for sulfurlike manganese, Mn X. The calculations are executed in an intermediate coupling scheme using the Breit-Pauli Hamiltonian. As well as, energy levels and oscillator strengths are calculated using LANL code, where the calculations by LANL have been used to estimate the accuracy of the present CI calculations. The calculated energy levels, oscillator strengths, and lifetimes are in reasonable agreement with the published experimental and theoretical values. Electron impact excitation rates of the transitions emit soft X-ray and extreme ultraviolet (EUV) wavelengths have been evaluated. The level population densities are calculated using the collisional radiative model (CRM), as well. The collisional excitation rates and collision strengths have been calculated in the electron temperature range ≤ the ionization potential, ∼1–250 eV.

  2. Relativistic electronic structure calculations on endohedral Gd rate at C60, La rate at C60, Gd rate at C74, and La rate at C74

    International Nuclear Information System (INIS)

    Lu, J.; Zhang, X.; Zhao, X.

    2000-01-01

    Relativistic discrete-variational local density functional calculations on endohedral Gd rate at C 60 , La rate at C 60 ,Gd rate at C 74 , and La rate at C 74 are performed. All the C 60 - and C 74 -derived levels are lowered upon endohedral Gd and La doping. Both the Gd (4f 7 5d 1 6s 2 ) and La (5d 1 6s 2 ) atoms only donate their two 6s valence electrons to the cages, leaving behind their 5d electrons when they are placed at the cage centers. Compared with large-band-gap C 60 , small-band-gap C 74 and Gd (La)-metallofullerenes have strong both electron-donating and electron-accepting characters, and the calculated ionization potentials and electron affinities for them agree well with the available experimental data. (orig.)

  3. 40 CFR 75.83 - Calculation of Hg mass emissions and heat input rate.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Calculation of Hg mass emissions and... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Hg Mass Emission Provisions § 75.83 Calculation of Hg mass emissions and heat input rate. The owner or operator shall calculate Hg mass emissions...

  4. Calculation of neutron and gamma-ray flux-to-dose-rate conversion factors

    International Nuclear Information System (INIS)

    Kwon, S.G.; Lee, S.Y.; Yook, C.C.

    1981-01-01

    This paper presents flux-to-dose-rate conversion factors for neutrons and gamma rays based on the American National Standard Institute (ANSI) N666. These data are used to calculate the dose rate distribution of neutron and gamma ray in radiation fields. Neutron flux-to-dose-rate conversion factors for energies from 2.5 x 10 -8 to 20 MeV are presented; the corresponding energy range for gamma rays is 0.01 to 15 MeV. Flux-to-dose-rate conversion factors were calculated, under the assumption that radiation energy distribution has nonlinearity in the phantom, have different meaning from those values obtained by monoenergetic radiation. Especially, these values were determined with the cross section library. The flux-to-dose-rate conversion factors obtained in this work were in a good agreement to the values presented by ANSI. Those data will be useful for the radiation shielding analysis and the radiation dosimetry in the case of continuous energy distributions. (author)

  5. Measurements of proton upset induced in Cmos devices synthesis of CEA studies

    International Nuclear Information System (INIS)

    Mijuin, D.; Buisson, J.; Brunet, J.P.; Murat, J.; Chapuis, T.

    1990-01-01

    Within its space activities, the Departement d'Electronique et d'Instrumentation Nucleaire (DEIN) is involved in a research program regarding the behaviour of electronic components submitted to the type of radiations encountered in earth orbits or by planetary probes. Located at Saclay, the SATURNE synchrotron is a tool well suited to simulate the effects of high energy cosmic particles. The DEIN has thus carried out several experimental runs in which CMOS SRAM were irradiated with a proton beam. SATURNE is a synchrotron designed for basic research in the physics of light particles and heavy ions of intermediate energy. The energy supplied to the protons lies between 0.2 and 2.9 GeV with an intensity larger than 10 12 protons cycle -1 . During the experiment and in order to lower the proton energy under 200 MeV, an Al-absorber was used. The flux measurement was obtained by two different methods: measurement by activation and measurement by counting (scintillator coupled with a PM). The increase number of upsets during irradiation was determined, on line, for each cycle, by a testor using a comparative hardware method. The testor was designed by the DEIN. Latch-up was also detected. The results, presented in this paper, were obtained during the run of September 1990. The upset cross-sections per bit of static memories MHS 65162. MHS 65641, MOSTEK 48H64 and HYUNDAI 6116 were measured for 1000, 200, 158.9, 147.5, 122.6, 93.3 and 66.2 MeV. These experimental values were fitted using the Bendel equation with two variable parameters proposed by Stapor and al (3). The results of the run of September 1990 encourage us to pursue our studies. By now, it seems necessary to improve the experimental line (elimination of the parasitic effects generated by the Al-absorber) and to upgrade the methods used for measuring the flux

  6. Densification of sintered molybdenum during hot upsetting: experiments and modelling

    International Nuclear Information System (INIS)

    Parteder, E.; Kopp, R.

    1999-01-01

    The densification behaviour of sintered molybdenum is investigated experimentally and by modelling using a pressure dependent plasticity model. Therefore the yield condition of Gurson, extended by Tvergaard is used. The uniaxial compression test is applied to determine the evolution of the density as well as the stress-strain curves for the porous metal. Powder metallurgical molybdenum exhibits closed porosity after consolidation due to sintering with nearly spherical shaped pores. The experimental results show that the densification, especially during the first stage of deformation, is different from that of powder compacts or partially consolidated powder materials with open porosity. During hot upsetting, the pores change their size and shape. This behaviour strongly affects the densification rate. For an accurate prediction of the evolution of the density using Gurson's model, the parameters q 1 and q 2 introduced by Tvergaard, will be defined as internal variables. The use of internal variables is justified by the fact that the pores change their shape during deformation, although the link between the internal variables and the pore shape is not explicitly established in this paper. If the loading is proportional (which means that the ratio of the stress-components does not change with plastic strain), the pore shape can be associated with the applied plastic strain. With this association the parameters q i can be defined as a function from the invariant quantity equivalent plastic strain, which can be used as the internal variable in the finite element simulation. The influence of the porosity on the flow stress at different levels of plastic strain will also be investigated and is used as a second information to fit both parameters q 1 and q 2 . (orig.)

  7. Calculation of recovery plasticity in multistage hot forging under isothermal conditions.

    Science.gov (United States)

    Zhbankov, Iaroslav G; Perig, Alexander V; Aliieva, Leila I

    2016-01-01

    A widely used method for hot forming steels and alloys, especially heavy forging, is the process of multistage forging with pauses between stages. The well-known effect which accompanies multistage hot forging is metal plasticity recovery in comparison with monotonic deformation. A method which takes into consideration the recovery of plasticity in pauses between hot deformations of a billet under isothermal conditions is proposed. This method allows the prediction of billet forming limits as a function of deformation during the forging stage and the duration of the pause between the stages. This method takes into account the duration of pauses between deformations and the magnitude of subdivided deformations. A hot isothermal upsetting process with pauses was calculated by the proposed method. Results of the calculations have been confirmed with experimental data.

  8. Monte Carlo simulation of particle-induced bit upsets

    Science.gov (United States)

    Wrobel, Frédéric; Touboul, Antoine; Vaillé, Jean-Roch; Boch, Jérôme; Saigné, Frédéric

    2017-09-01

    We investigate the issue of radiation-induced failures in electronic devices by developing a Monte Carlo tool called MC-Oracle. It is able to transport the particles in device, to calculate the energy deposited in the sensitive region of the device and to calculate the transient current induced by the primary particle and the secondary particles produced during nuclear reactions. We compare our simulation results with SRAM experiments irradiated with neutrons, protons and ions. The agreement is very good and shows that it is possible to predict the soft error rate (SER) for a given device in a given environment.

  9. Monte Carlo simulation of particle-induced bit upsets

    Directory of Open Access Journals (Sweden)

    Wrobel Frédéric

    2017-01-01

    Full Text Available We investigate the issue of radiation-induced failures in electronic devices by developing a Monte Carlo tool called MC-Oracle. It is able to transport the particles in device, to calculate the energy deposited in the sensitive region of the device and to calculate the transient current induced by the primary particle and the secondary particles produced during nuclear reactions. We compare our simulation results with SRAM experiments irradiated with neutrons, protons and ions. The agreement is very good and shows that it is possible to predict the soft error rate (SER for a given device in a given environment.

  10. Influence of edge effects on single event upset susceptibility of SOI SRAMs

    International Nuclear Information System (INIS)

    Gu, Song; Liu, Jie; Zhao, Fazhan; Zhang, Zhangang; Bi, Jinshun; Geng, Chao; Hou, Mingdong; Liu, Gang; Liu, Tianqi; Xi, Kai

    2015-01-01

    An experimental investigation of the single event upset (SEU) susceptibility for heavy ions at tilted incidence was performed. The differences of SEU cross-sections between tilted incidence and normal incidence at equivalent effective linear energy transfer were 21% and 57% for the silicon-on-insulator (SOI) static random access memories (SRAMs) of 0.5 μm and 0.18 μm feature size, respectively. The difference of SEU cross-section raised dramatically with increasing tilt angle for SOI SRAM of deep-submicron technology. The result of CRÈME-MC simulation for tilted irradiation of the sensitive volume indicates that the energy deposition spectrum has a substantial tail extending into the low energy region. The experimental results show that the influence of edge effects on SEU susceptibility cannot be ignored in particular with device scaling down

  11. Self-efficacy for controlling upsetting thoughts and emotional eating in family caregivers.

    Science.gov (United States)

    MacDougall, Megan; Steffen, Ann

    2017-10-01

    Self-efficacy for controlling upsetting thoughts was examined as a predictor of emotional eating by family caregivers of physically and cognitively impaired older adults. Adult women (N = 158) providing healthcare assistance for an older family member completed an online survey about caregiving stressors, depressive symptoms, self-efficacy, and emotional eating. A stress process framework was used as a conceptual model to guide selection of variables predicting emotional eating scores. A hierarchical multiple regression was conducted and the overall model was significant (R 2 = .21, F(4,153) = 10.02, p accounting for IADL, role overload, and depression scores. These findings replicate previous research demonstrating the relationship between managing cognitions about caregiving and behavioral responses to stressors, and point to the importance of addressing cognitive processes in efforts to improve caregiver health behaviors.

  12. Single-Event Upset and Scaling Trends in New Generation of the Commercial SOI PowerPC Microprocessors

    Science.gov (United States)

    Irom, Farokh; Farmanesh, Farhad; Kouba, Coy K.

    2006-01-01

    Single-event upset effects from heavy ions are measured for Motorola silicon-on-insulator (SOI) microprocessor with 90 nm feature sizes. The results are compared with previous results for SOI microprocessors with feature sizes of 130 and 180 nm. The cross section of the 90 nm SOI processors is smaller than results for 130 and 180 nm counterparts, but the threshold is about the same. The scaling of the cross section with reduction of feature size and core voltage for SOI microprocessors is discussed.

  13. 31 CFR 356.21 - How are awards at the high yield or discount rate calculated?

    Science.gov (United States)

    2010-07-01

    ... discount rate calculated? 356.21 Section 356.21 Money and Finance: Treasury Regulations Relating to Money... high yield or discount rate calculated? (a) Awards to submitters. We generally prorate bids at the highest accepted yield or discount rate under § 356.20(a)(2) of this part. For example, if 80.15% is the...

  14. To Leave a Praxis to Itself May Be to Upset It in Unintended Ways

    DEFF Research Database (Denmark)

    Olsen, Poul Bitsch; Axel, Erik

    by the researchers on a conception of situated praxis, of conflictual cooperation, and on an interest in morals and the meaning of upsetting practices. The organization of the material may hopefully provoke discussions around praxis as part of its further development. Thus, our presentation is based on a notion...... of praxis. Praxis is formed by the reciprocal differentiations of acts. In order to be able to act here, we try to arrange things to be done in specific ways there. In order to build the house here, we arrange a supply of inhabitants here, a conglomerate of producers there etc.. Furthermore, what we achieve...

  15. Calculation of hydrogen outgassing rate of LHD by recombination limited model

    International Nuclear Information System (INIS)

    Akaishi, K.; Nakasuga, M.

    2002-04-01

    To simulate hydrogen outgassing in the plasma vacuum vessel of LHD, the recombination limited model is presented, where the time evolution of hydrogen concentration in the wall of the plasma vacuum vessel is described by a one-dimensional diffusion equation. The hydrogen outgassing rates when the plasma vacuum vessel is pumped down at room temperature and baked at 100 degC are calculated as a function of pumping time. The calculation shows that the hydrogen outgassing rate of the plasma vacuum vessel can be reduced at least by one order of magnitude due to pumping and baking. This prediction is consistent with the recent result of outgassing reduction observed in the pumping-down and baking of the plasma vacuum vessel in LHD. (author)

  16. Feasibility of a neutron detector-dosemeter based on single-event upsets in dynamic random-access memories

    International Nuclear Information System (INIS)

    Phillips, G.W.; August, R.A.; Campbell, A.B.; Nelson, M.E.; Guardala, N.A.; Price, J.L.; Moscovitch, M.

    2002-01-01

    The feasibility was investigated of a solid-state neutron detector/dosemeter based on single-event upset (SEU) effects in dynamic random-access memories (DRAMs), commonly used in computer memories. Such a device, which uses a neutron converter material to produce a charged particle capable of causing an upset, would be light-weight, low-power, and could be read simply by polling the memory for bit flips. It would have significant advantages over standard solid-state neutron dosemeters which require off-line processing for track etching and analysis. Previous efforts at developing an SEU neutron detector/dosemeter have suffered from poor response, which can be greatly enhanced by selecting a modern high-density DRAM chip for SEU sensitivity and by using a thin 10 B film as a converter. Past attempts to use 10 B were not successful because the average alpha particle energy was insufficient to penetrate to the sensitive region of the memory. This can be overcome by removing the surface passivation layer before depositing the 10 B film or by implanting 10B directly into the chip. Previous experimental data show a 10 3 increase in neutron sensitivity by chips containing borosilicate glass, which could be used in an SEU detector. The results are presented of simulations showing that the absolute efficiency of an SEU neutron dosemeter can be increased by at least a factor of 1000 over earlier designs. (author)

  17. 39 CFR 3010.23 - Calculation of percentage change in rates.

    Science.gov (United States)

    2010-07-01

    ... DOMINANT PRODUCTS Rules for Applying the Price Cap § 3010.23 Calculation of percentage change in rates. (a... Postal Service billing determinants. The Postal Service shall make reasonable adjustments to the billing determinants to account for the effects of classification changes such as the introduction, deletion, or...

  18. Distorted wave approach to calculate Auger transition rates of ions in metals

    Energy Technology Data Exchange (ETDEWEB)

    Deutscher, Stefan A. E-mail: sad@utk.edu; Diez Muino, R.; Arnau, A.; Salin, A.; Zaremba, E

    2001-08-01

    We evaluate the role of target distortion in the determination of Auger transition rates for multicharged ions in metals. The required two electron matrix elements are calculated using numerical solutions of the Kohn-Sham equations for both the bound and continuum states. Comparisons with calculations performed using plane waves and hydrogenic orbitals are presented.

  19. Dose rates from a C-14 source using extrapolation chamber and MC calculations

    International Nuclear Information System (INIS)

    Borg, J.

    1996-05-01

    The extrapolation chamber technique and the Monte Carlo (MC) calculation technique based on the EGS4 system have been studied for application for determination of dose rates in a low-energy β radiation field e.g., that from a 14 C source. The extrapolation chamber measurement method is the basic method for determination of dose rates in β radiation fields. Applying a number of correction factors and the stopping power ratio, tissue to air, the measured dose rate in an air volume surrounded by tissue equivalent material is converted into dose to tissue. Various details of the extrapolation chamber measurement method and evaluation procedure have been studied and further developed, and a complete procedure for the experimental determination of dose rates from a 14 C source is presented. A number of correction factors and other parameters used in the evaluation procedure for the measured data have been obtained by MC calculations. The whole extrapolation chamber measurement procedure was simulated using the MC method. The measured dose rates showed an increasing deviation from the MC calculated dose rates as the absorber thickness increased. This indicates that the EGS4 code may have some limitations for transport of very low-energy electrons. i.e., electrons with estimated energies less than 10 - 20 keV. MC calculations of dose to tissue were performed using two models: a cylindrical tissue phantom and a computer model of the extrapolation chamber. The dose to tissue in the extrapolation chamber model showed an additional buildup dose compared to the dose in the tissue model. (au) 10 tabs., 11 ills., 18 refs

  20. THIDA: code system for calculation of the exposure dose rate around a fusion device

    International Nuclear Information System (INIS)

    Iida, Hiromasa; Igarashi, Masahito.

    1978-12-01

    A code system THIDA has been developed for calculation of the exposure dose rates around a fusion device. It consists of the following: one- and two-dimensional discrete ordinate transport codes; induced activity calculation code; activation chain, activation cross section, radionuclide gamma-ray energy/intensity and gamma-ray group constant files; and gamma ray flux to exposure dose rate conversion coefficients. (author)

  1. Survey of Quantitative Research Metrics to Assess Pilot Performance in Upset Recovery

    Science.gov (United States)

    Le Vie, Lisa R.

    2016-01-01

    Accidents attributable to in-flight loss of control are the primary cause for fatal commercial jet accidents worldwide. The National Aeronautics and Space Administration (NASA) conducted a literature review to determine and identify the quantitative standards for assessing upset recovery performance. This review contains current recovery procedures for both military and commercial aviation and includes the metrics researchers use to assess aircraft recovery performance. Metrics include time to first input, recognition time and recovery time and whether that input was correct or incorrect. Other metrics included are: the state of the autopilot and autothrottle, control wheel/sidestick movement resulting in pitch and roll, and inputs to the throttle and rudder. In addition, airplane state measures, such as roll reversals, altitude loss/gain, maximum vertical speed, maximum/minimum air speed, maximum bank angle and maximum g loading are reviewed as well.

  2. X particle effect for 6Li reaction rates calculations

    International Nuclear Information System (INIS)

    Kocak, G.; Balantekin, A. B.

    2009-01-01

    The inferred primordial 6 L i-7 L i abundances are different from standard big bang nucleosynthesis results, 6 L i is 1000 times larger and 7 L i is 3 times smaller than the big bang prediction. In big bang nucleosynthesis, negatively charged massive X particles a possible solution to explain this primordial Li abundances problem [1]. In this study, we consider only X particle effect for nuclear reactions to obtain S-factor and reaction rates for Li. All S-factors calculated within the Optical Model framework for d(α,γ)6 L i system. We showed that the enhancement effect of massive negatively charged X particle for 6 L i system reaction rate.(author)

  3. The correlation schemes in calculations of the rate constants of some radiation chemical reactions

    International Nuclear Information System (INIS)

    Zagorets, P.A.; Shostenko, A.G.; Kim, V.

    1983-01-01

    The various correlation relationships of the evaluation of the rate constants of radiation chemical reactions of addition, abstraction and isomerization were considered. It was shown that neglection of the influence of solvent can result in errors in calculations of rate constants equalling two orders in magnitude. Several examples of isokinetic relationship are given. The methods of calculation of transmission coefficient of reaction addition have been discussed. (author)

  4. Calculation of expected rates of fisheries‐induced evolution in data‐poor situations

    DEFF Research Database (Denmark)

    Andersen, Ken Haste

    2010-01-01

    A central part of an impact assessment of the evolutionary effects of fishing is a calculation of the expected rates of fishing induced by current fishing practice and an evaluation of how alternative fishing patterns may reduce evolutionary impacts of fishing. Here a general size-based framework...... for modeling the demography of fish based on size-based prescriptions of natural mortality, growth, and fishing is presented. Life history theory is used to reduce the necessary parameter set by utilizing relations between parameters making the framework particularly well suited for data-poor situations where...... only the size at maturation or the asymptotic size is known. The framework is applied to perform the modeling part of an evolutionary impact assessment using basic quantitative genetics to calculated expected rates of evolution on size at maturation, growth rate, and investment in gonads. A sensitivity...

  5. Advanced local dose rate calculations with the Monte Carlo code MCNP for plutonium nitrate storage containers

    International Nuclear Information System (INIS)

    Quade, U.

    1994-01-01

    Neutron- und Gamma dose rate calculations were performed for the storage containers filled with plutonium nitrate of the MOX fabrication facility of Siemens. For the particle transport calculations the Monte Carlo Code MCNP 4.2 was used. The calculated results were compared with experimental dose rate measurements. It can be stated that the choice of the code system was appropriate since all aspects of the many facettes of the problem were well reproduced in the calculations. The position dependency as well as the influence of the shieldings, the reflections and the mutual influences of the sources were well described by the calculations for the gamma and for the neutron dose rates. However, good agreement with the experimental results on the gamma dose rates could only be reached when the lead shielding of the detector was integrated into the geometry modelling of the calculations. For some few cases of thick shieldings and soft gamma ray sources the statistics of the calculational results were not sufficient. In such cases more elaborate variance reduction methods must be applied in future calculations. Thus the MCNP code in connection with NGSRC has been proven as an effective tool for the solution of this type of problems. (orig./HP) [de

  6. Glass dissolution rate measurement and calculation revisited

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, Maxime, E-mail: maxime.fournier@cea.fr [CEA, DEN, DTCD, SECM, F-30207, Bagnols sur Cèze (France); Ull, Aurélien; Nicoleau, Elodie [CEA, DEN, DTCD, SECM, F-30207, Bagnols sur Cèze (France); Inagaki, Yaohiro [Department of Applied Quantum Physics & Nuclear Engineering, Kyushu University, Fukuoka, 819-0395 (Japan); Odorico, Michaël [ICSM-UMR5257 CEA/CNRS/UM2/ENSCM, Site de Marcoule, BP17171, F-30207, Bagnols sur Cèze (France); Frugier, Pierre; Gin, Stéphane [CEA, DEN, DTCD, SECM, F-30207, Bagnols sur Cèze (France)

    2016-08-01

    Aqueous dissolution rate measurements of nuclear glasses are a key step in the long-term behavior study of such waste forms. These rates are routinely normalized to the glass surface area in contact with solution, and experiments are very often carried out using crushed materials. Various methods have been implemented to determine the surface area of such glass powders, leading to differing values, with the notion of the reactive surface area of crushed glass remaining vague. In this study, around forty initial dissolution rate measurements were conducted following static and flow rate (SPFT, MCFT) measurement protocols at 90 °C, pH 10. The international reference glass (ISG), in the forms of powders with different particle sizes and polished monoliths, and soda-lime glass beads were examined. Although crushed glass grains clearly cannot be assimilated with spheres, it is when using the samples geometric surface (S{sub geo}) that the rates measured on powders are closest to those found for monoliths. Overestimation of the reactive surface when using the BET model (S{sub BET}) may be due to small physical features at the atomic scale—contributing to BET surface area but not to AFM surface area. Such features are very small compared with the thickness of water ingress in glass (a few hundred nanometers) and should not be considered in rate calculations. With a S{sub BET}/S{sub geo} ratio of 2.5 ± 0.2 for ISG powders, it is shown here that rates measured on powders and normalized to S{sub geo} should be divided by 1.3 and rates normalized to S{sub BET} should be multiplied by 1.9 in order to be compared with rates measured on a monolith. The use of glass beads indicates that the geometric surface gives a good estimation of glass reactive surface if sample geometry can be precisely described. Although data clearly shows the repeatability of measurements, results must be given with a high uncertainty of approximately ±25%. - Highlights: • Initial dissolution

  7. Preliminary calculations on the cooling rate of the Renca batholit, Sierra de San Luis, Argentina

    International Nuclear Information System (INIS)

    Lopez de Luchi, M.G.; Ostera, H.A.; Linares, E; Rosello, E.A

    2001-01-01

    Cooling rates can be used to constrain the unroofing history of plutonic-metamorphic system. Geocronological cooling rates (Spear and Parrish, 1996) can be unravelled using age calculations on minerals that were open systems and subsequently passed through their closure temperatures (Dodson, 1973) during cooling. Several age determinations on different minerals are needed in order to accurately constrain the cooling path of a pluton (Hodges 1991, Spear and Parrish, 1996 and references therein). Isotopic open-system behaviour in minerals can be modelled as volume diffusion process (Hodges, 1991 and references therein), which depends on the cooling rate of the whole system. We present the first results on the calculation of the cooling rate of the Renca batholith on the basis of the combination of both thermometric calculations and available crystallization and cooling ages (au)

  8. Measuring the upset of CMOS and TTL due to HPM-signals

    Directory of Open Access Journals (Sweden)

    N. Esser

    2004-01-01

    Full Text Available To measure the performance of electronic components when stressed by High Power Microwave signals a setup was designed and tested which allows a well-defined voltage signal to enter the component during normal operation, and to discriminate its effect on the component. The microwave signal is fed to the outside conductor of a coaxial cable and couples into the inner signal line connected to the device under test (DUT. The disturbing HF-signal is transferred almost independent from frequency to maintain the pulse shape in the time domain. The configuration designed to perform a TEM-coupling within a 50 Ohm system prevents the secondary system from feeding back to the primary system and, due to the geometrical parameters chosen, the coupling efficiency is as high as 50–90%. Linear dimensions and terminations applied allow for pulses up to a width of 12ns and up to a voltage level of 4–5 kV on the outside conductor. These pulse parameters proved to be sufficient to upset the DUTs tested so far. In more than 400 measurements a rectangular pulse of increasing voltage level was applied to different types of CMOS and TTL until the individual DUT was damaged. As well the pulse width (3, 6 or 12 ns and its polarity were varied in single-shot or repetitive-shot experiments (500 shots per voltage at a repetition rate of 3 Hz. The state of the DUT was continuously monitored by measuring both the current of the DUT circuit and that of the oscillator providing the operating signal for the DUT. The results show a very good reproducibility within a set of identical samples, remarkable differences between manufacturers and lower thresholds for repetitive testing, which indicates a memory effect of the DUT to exist for voltage levels significantly below the single-shot threshold.

  9. CREME96 and Related Error Rate Prediction Methods

    Science.gov (United States)

    Adams, James H., Jr.

    2012-01-01

    Predicting the rate of occurrence of single event effects (SEEs) in space requires knowledge of the radiation environment and the response of electronic devices to that environment. Several analytical models have been developed over the past 36 years to predict SEE rates. The first error rate calculations were performed by Binder, Smith and Holman. Bradford and Pickel and Blandford, in their CRIER (Cosmic-Ray-Induced-Error-Rate) analysis code introduced the basic Rectangular ParallelePiped (RPP) method for error rate calculations. For the radiation environment at the part, both made use of the Cosmic Ray LET (Linear Energy Transfer) spectra calculated by Heinrich for various absorber Depths. A more detailed model for the space radiation environment within spacecraft was developed by Adams and co-workers. This model, together with a reformulation of the RPP method published by Pickel and Blandford, was used to create the CR ME (Cosmic Ray Effects on Micro-Electronics) code. About the same time Shapiro wrote the CRUP (Cosmic Ray Upset Program) based on the RPP method published by Bradford. It was the first code to specifically take into account charge collection from outside the depletion region due to deformation of the electric field caused by the incident cosmic ray. Other early rate prediction methods and codes include the Single Event Figure of Merit, NOVICE, the Space Radiation code and the effective flux method of Binder which is the basis of the SEFA (Scott Effective Flux Approximation) model. By the early 1990s it was becoming clear that CREME and the other early models needed Revision. This revision, CREME96, was completed and released as a WWW-based tool, one of the first of its kind. The revisions in CREME96 included improved environmental models and improved models for calculating single event effects. The need for a revision of CREME also stimulated the development of the CHIME (CRRES/SPACERAD Heavy Ion Model of the Environment) and MACREE (Modeling and

  10. Resolving an ostensible inconsistency in calculating the evaporation rate of sessile drops.

    Science.gov (United States)

    Chini, S F; Amirfazli, A

    2017-05-01

    This paper resolves an ostensible inconsistency in the literature in calculating the evaporation rate for sessile drops in a quiescent environment. The earlier models in the literature have shown that adapting the evaporation flux model for a suspended spherical drop to calculate the evaporation rate of a sessile drop needs a correction factor; the correction factor was shown to be a function of the drop contact angle, i.e. f(θ). However, there seemed to be a problem as none of the earlier models explicitly or implicitly mentioned the evaporation flux variations along the surface of a sessile drop. The more recent evaporation models include this variation using an electrostatic analogy, i.e. the Laplace equation (steady-state continuity) in a domain with a known boundary condition value, or known as the Dirichlet problem for Laplace's equation. The challenge is that the calculated evaporation rates using the earlier models seemed to differ from that of the recent models (note both types of models were validated in the literature by experiments). We have reinvestigated the recent models and found that the mathematical simplifications in solving the Dirichlet problem in toroidal coordinates have created the inconsistency. We also proposed a closed form approximation for f(θ) which is valid in a wide range, i.e. 8°≤θ≤131°. Using the proposed model in this study, theoretically, it was shown that the evaporation rate in the CWA (constant wetted area) mode is faster than the evaporation rate in the CCA (constant contact angle) mode for a sessile drop. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Shell model calculations for levels and transition rates in 204Pb and 206Pb

    International Nuclear Information System (INIS)

    Wang, D.; McEllistrem, M.T.

    1990-01-01

    Level energies and decay rates of both negative and positive parity levels of 206,204 Pb have been calculated through mixed-configuration shell model calculations using the modified surface delta interaction (MSDI), the Schiffer-True central interaction, and another two-body interaction. These calculations were all carried out with a full six-orbit neutron hole space. The predicted low-lying levels with the MSDI are in excellent agreement with experiments, accounting for the energies, spins, and parities of essentially all levels below 3 MeV excitation energy except known particle-hole collective excitations in both nuclei. Almost all calculated E2 and M1 transition rates are consistent with measured branching ratios for γ-ray decay of excited levels. The comparison of the observed and calculated levels demonstrates the important role played by the neutron-hole i 13/2 configuration in the levels of 204 Pb and 206 Pb, and interprets an apparent discrepancy over the character and energy spacings of 0 + levels in 204 Pb

  12. Influences of lubricant pocket geometry and working conditions upon micro lubrication mechanisms in upsetting and strip drawing

    DEFF Research Database (Denmark)

    Shimizu, Ichiro; Martins, P. A. F.; Bay, Niels

    2010-01-01

    , during upsetting and strip drawing, by means of a rigid-viscoplastic finite-element formulation. Special emphasis is placed on the effect of pocket geometry on the build-up of hydrostatic pressure, which is responsible for the onset of micro-lubrication mechanisms. A good agreement is found between......Micro-lubricant pockets located in the surface of plastically deforming workpieces are recognised to improve the performance of fluid lubrication in a metal-forming process. This work investigates the joint influence of pocket geometry and process working conditions on micro-lubrication mechanisms...

  13. Examination of the semi-automatic calculation technique of vegetation cover rate by digital camera images.

    Science.gov (United States)

    Takemine, S.; Rikimaru, A.; Takahashi, K.

    The rice is one of the staple foods in the world High quality rice production requires periodically collecting rice growth data to control the growth of rice The height of plant the number of stem the color of leaf is well known parameters to indicate rice growth Rice growth diagnosis method based on these parameters is used operationally in Japan although collecting these parameters by field survey needs a lot of labor and time Recently a laborsaving method for rice growth diagnosis is proposed which is based on vegetation cover rate of rice Vegetation cover rate of rice is calculated based on discriminating rice plant areas in a digital camera image which is photographed in nadir direction Discrimination of rice plant areas in the image was done by the automatic binarization processing However in the case of vegetation cover rate calculation method depending on the automatic binarization process there is a possibility to decrease vegetation cover rate against growth of rice In this paper a calculation method of vegetation cover rate was proposed which based on the automatic binarization process and referred to the growth hysteresis information For several images obtained by field survey during rice growing season vegetation cover rate was calculated by the conventional automatic binarization processing and the proposed method respectively And vegetation cover rate of both methods was compared with reference value obtained by visual interpretation As a result of comparison the accuracy of discriminating rice plant areas was increased by the proposed

  14. STEADY STATE FLAMMABLE GAS RELEASE RATE CALCULATION AND LOWER FLAMMABILITY LEVEL EVALUATION FOR HANFORD TANK WASTE

    Energy Technology Data Exchange (ETDEWEB)

    HU TA

    2009-10-26

    Assess the steady-state flammability level at normal and off-normal ventilation conditions. The hydrogen generation rate was calculated for 177 tanks using the rate equation model. Flammability calculations based on hydrogen, ammonia, and methane were performed for 177 tanks for various scenarios.

  15. A comparison of measured and calculated values of air kerma rates from 137Cs in soil

    Directory of Open Access Journals (Sweden)

    V. P. Ramzaev

    2015-01-01

    Full Text Available In 2010, a study was conducted to determine the air gamma dose rate from 137Cs deposited in soil. The gamma dose rate measurements and soil sampling were performed at 30 reference plots from the south-west districts of the Bryansk region (Russia that had been heavily contaminated as a result of the Chernobyl accident. The 137Cs inventory in the top 20 cm of soil ranged from 260 kBq m–2 to 2800 kBq m–2. Vertical distributions of 137Cs in soil cores (6 samples per a plot were determined after their sectioning into ten horizontal layers of 2 cm thickness. The vertical distributions of 137Cs in soil were employed to calculate air kerma rates, K, using two independent methods proposed by Saito and Jacob [Radiat. Prot. Dosimetry, 1995, Vol. 58, P. 29–45] and Golikov et al. [Contaminated Forests– Recent Developments in Risk Identification and Future Perspective. Kluwer Academic Publishers, 1999. – P. 333–341]. A very good coincidence between the methods was observed (Spearman’s rank coefficient of correlation = 0.952; P<0.01; on average, a difference between the kerma rates calculated with two methods did not exceed 3%. The calculated air kerma rates agreed with the measured dose rates in air very well (Spearman’s coefficient of correlation = 0.952; P<0.01. For large grassland plots (n=19, the measured dose rates were on average 6% less than the calculated kerma rates. The tested methods for calculating the air dose rate from 137Cs in soil can be recommended for practical studies in radiology and radioecology. 

  16. Linear constraint relations in biochemical reaction systems: I. Classification of the calculability and the balanceability of conversion rates.

    Science.gov (United States)

    van der Heijden, R T; Heijnen, J J; Hellinga, C; Romein, B; Luyben, K C

    1994-01-05

    Measurements provide the basis for process monitoring and control as well as for model development and validation. Systematic approaches to increase the accuracy and credibility of the empirical data set are therefore of great value. In (bio)chemical conversions, linear conservation relations such as the balance equations for charge, enthalpy, and/or chemical elements, can be employed to relate conversion rates. In a pactical situation, some of these rates will be measured (in effect, be calculated directly from primary measurements of, e.g., concentrations and flow rates), as others can or cannot be calculated from the measured ones. When certain measured rates can also be calculated from other measured rates, the set of equations, the accuracy and credibility of the measured rates can indeed be improved by, respectively, balancing and gross error diagnosis. The balanced conversion rates are more accurate, and form a consistent set of data, which is more suitable for further application (e.g., to calculate nonmeasured rates) than the raw measurements. Such an approach has drawn attention in previous studies. The current study deals mainly with the problem of mathematically classifying the conversion rates into balanceable and calculable rates, given the subset of measured rates. The significance of this problem is illustrated with some examples. It is shown that a simple matrix equation can be derived that contains the vector of measured conversion rates and the redundancy matrix R. Matrix R plays a predominant role in the classification problem. In supplementary articles, significance of the redundancy matrix R for an improved gross error diagnosis approach will be shown. In addition, efficient equations have been derived to calculate the balanceable and/or calculable rates. The method is completely based on matrix algebra (principally different from the graph-theoretical approach), and it is easily implemented into a computer program. (c) 1994 John Wiley & Sons

  17. Radiological dose rate calculations for the International Thermonuclear Experimental Reactor (ITER)

    International Nuclear Information System (INIS)

    Khater, H.Y.; Santoro, R.T.

    1996-01-01

    Two-dimensional biological dose rates were calculated at different locations outside the International Thermonuclear Experimental Reactor (ITER) design. An 18 degree sector of the reactor was modeled in r-θ geometry. The calculations were performed for three different pulsing scenarios. This included a single pulse of 1000 s duration, 10 pulses of 1000 s duration with a 50% duty factor, and 9470 pulses of 1000 s duration with a 50% duty factor for a total fluence of 0.3 MW.a/m 2 . The dose rates were calculated as a function of toroidal angle at locations in the space between the toroidal field (TF) coils and cryostat, and in the space between the cryostat and the biological shield. The two-dimensional results clearly showed the toroidal effect, which is dominated by contribution from the activation of the cryostat and the biological shield. After one pulse, full access to the machine is possible within a few hours following shutdown. After 10 pulses, full access is also possible within the first day following shutdown. At the end of the Basic Performance Phase (BPP), full access is possible at any of the locations considered after one week following shutdown. 5 refs., 5 figs., 2 tabs

  18. Experiments and calculations to leak openings and leak rates on typical piping components and systems

    International Nuclear Information System (INIS)

    Hoefler, A.; Grebner, H.

    1992-01-01

    Calculations of leak opening and leak rate for through cracks in piping components have been performed. The analyses are pre- or mostly post-calculations to experiments performed at the HDR facility under PWR operating conditions. Piping components under consideration are small diameter straight pipes with circumferential cracks, pipe bends with longitudinal or circumferential cracks and pipe branches with weldment cracks. The component are loaded by internal pressure and opening as well as closing bending moment. The finite element method and two-phase flow leak rate programs are used for the calculations. Results of the analyses are presented as J-integral values, crack opening displacements and areas and leak rates as well as comparisons to the experimental results. 6 refs., 16 figs., 2 tabs

  19. Calculation of heat rating and burn-up for test fuel pins irradiated in DR 3

    International Nuclear Information System (INIS)

    Bagger, C.; Carlsen, H.; Hansen, K.

    1980-01-01

    A summary of the DR 3 reactor and HP1 rig design is given followed by a detailed description of the calculation procedure for obtaining linear heat rating and burn-up values of fuel pins irradiated in HP1 rigs. The calculations are carried out rather detailed, especially regarding features like end pellet contribution to power as a function of burn-up, gamma heat contributions, and evaluation of local values of heat rating and burn-up. Included in the report is also a description of the fast flux- and cladding temperature calculation techniques currently used. A good agreement between measured and calculated local burn-up values is found. This gives confidence to the detailed treatment of the data. (author)

  20. Large-scale calculations of the beta-decay rates and r-process nucleosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Borzov, I N; Goriely, S [Inst. d` Astronomie et d` Astrophysique, Univ. Libre de Bruxelles, Campus Plaine, Bruxelles (Belgium); Pearson, J M [Inst. d` Astronomie et d` Astrophysique, Univ. Libre de Bruxelles, Campus Plaine, Bruxelles (Belgium); [Lab. de Physique Nucleaire, Univ. de Montreal, Montreal (Canada)

    1998-06-01

    An approximation to a self-consistent model of the ground state and {beta}-decay properties of neutron-rich nuclei is outlined. The structure of the {beta}-strength functions in stable and short-lived nuclei is discussed. The results of large-scale calculations of the {beta}-decay rates for spherical and slightly deformed nuclides of relevance to the r-process are analysed and compared with the results of existing global calculations and recent experimental data. (orig.)

  1. Calculation of the soft error rate of submicron CMOS logic circuits

    International Nuclear Information System (INIS)

    Juhnke, T.; Klar, H.

    1995-01-01

    A method to calculate the soft error rate (SER) of CMOS logic circuits with dynamic pipeline registers is described. This method takes into account charge collection by drift and diffusion. The method is verified by comparison of calculated SER's to measurement results. Using this method, the SER of a highly pipelined multiplier is calculated as a function of supply voltage for a 0.6 microm, 0.3 microm, and 0.12 microm technology, respectively. It has been found that the SER of such highly pipelined submicron CMOS circuits may become too high so that countermeasures have to be taken. Since the SER greatly increases with decreasing supply voltage, low-power/low-voltage circuits may show more than eight times the SER for half the normal supply voltage as compared to conventional designs

  2. Comparison of measured and calculated reaction rate distributions in an scwr-like test lattice

    Energy Technology Data Exchange (ETDEWEB)

    Raetz, Dominik, E-mail: dominik.raetz@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Jordan, Kelly A., E-mail: kelly.jordan@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Murphy, Michael F., E-mail: mike.murphy@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Perret, Gregory, E-mail: gregory.perret@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Chawla, Rakesh, E-mail: rakesh.chawla@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Ecole Polytechnique Federale de Lausanne (EPFL), CH-1015 Lausanne, EPFL (Switzerland)

    2011-04-15

    High resolution gamma-ray spectroscopy measurements were performed on 61 rods of an SCWR-like fuel lattice, after irradiation in the central test zone of the PROTEUS zero-power research reactor at the Paul Scherrer Institute in Switzerland. The derived reaction rates are the capture rate in {sup 238}U (C{sub 8}) and the total fission rate (F{sub tot}), and also the reaction rate ratio C{sub 8}/F{sub tot}. Each of these has been mapped rod-wise on the lattice and compared to calculated results from whole-reactor Monte Carlo simulations with MCNPX. Ratios of calculated to experimental values (C/E's) have been assessed for the C{sub 8}, F{sub tot} and C{sub 8}/F{sub tot} distributions across the lattice. These C/E's show excellent agreement between the calculations and the measurements. For the {sup 238}U capture rate distribution, the 1{sigma} level in the comparisons corresponds to an uncertainty of {+-}0.8%, while for the total fission rate the corresponding value is {+-}0.4%. The uncertainty for C{sub 8}/F{sub tot}, assessed as a reaction rate ratio characterizing each individual rod position in the test lattice, is significantly higher at {+-}2.2%. To determine the reproducibility of these results, the measurements were performed twice, once in 2006 and again in 2009. The agreement between these two measurement sets is within the respective statistical uncertainties.

  3. Locating the rate-limiting step for the interaction of hydrogen with Mg(0001) using density-functional theory calculations and rate theory

    DEFF Research Database (Denmark)

    Vegge, Tejs

    2004-01-01

    The dissociation of molecular hydrogen on a Mgs0001d surface and the subsequent diffusion of atomic hydrogen into the magnesium substrate is investigated using Density Functional Theory (DFT) calculations and rate theory. The minimum energy path and corresponding transition states are located usi...... to be rate-limiting for the ab- and desorption of hydrogen, respectively. Zero-point energy contributions are found to be substantial for the diffusion of atomic hydrogen, but classical rates are still found to be within an order of magnitude at room temperature.......The dissociation of molecular hydrogen on a Mgs0001d surface and the subsequent diffusion of atomic hydrogen into the magnesium substrate is investigated using Density Functional Theory (DFT) calculations and rate theory. The minimum energy path and corresponding transition states are located using...

  4. MO-D-213-07: RadShield: Semi- Automated Calculation of Air Kerma Rate and Barrier Thickness

    International Nuclear Information System (INIS)

    DeLorenzo, M; Wu, D; Rutel, I; Yang, K

    2015-01-01

    Purpose: To develop the first Java-based semi-automated calculation program intended to aid professional radiation shielding design. Air-kerma rate and barrier thickness calculations are performed by implementing NCRP Report 147 formalism into a Graphical User Interface (GUI). The ultimate aim of this newly created software package is to reduce errors and improve radiographic and fluoroscopic room designs over manual approaches. Methods: Floor plans are first imported as images into the RadShield software program. These plans serve as templates for drawing barriers, occupied regions and x-ray tube locations. We have implemented sub-GUIs that allow the specification in regions and equipment for occupancy factors, design goals, number of patients, primary beam directions, source-to-patient distances and workload distributions. Once the user enters the above parameters, the program automatically calculates air-kerma rate at sampled points beyond all barriers. For each sample point, a corresponding minimum barrier thickness is calculated to meet the design goal. RadShield allows control over preshielding, sample point location and material types. Results: A functional GUI package was developed and tested. Examination of sample walls and source distributions yields a maximum percent difference of less than 0.1% between hand-calculated air-kerma rates and RadShield. Conclusion: The initial results demonstrated that RadShield calculates air-kerma rates and required barrier thicknesses with reliable accuracy and can be used to make radiation shielding design more efficient and accurate. This newly developed approach differs from conventional calculation methods in that it finds air-kerma rates and thickness requirements for many points outside the barriers, stores the information and selects the largest value needed to comply with NCRP Report 147 design goals. Floor plans, parameters, designs and reports can be saved and accessed later for modification and recalculation

  5. MO-D-213-07: RadShield: Semi- Automated Calculation of Air Kerma Rate and Barrier Thickness

    Energy Technology Data Exchange (ETDEWEB)

    DeLorenzo, M [Oklahoma University Health Sciences Center, Oklahoma City, OK (United States); Wu, D [University of Oklahoma Health Sciences Center, Oklahoma City, Ok (United States); Rutel, I [University of Oklahoma Health Science Center, Oklahoma City, OK (United States); Yang, K [Massachusetts General Hospital, Boston, MA (United States)

    2015-06-15

    Purpose: To develop the first Java-based semi-automated calculation program intended to aid professional radiation shielding design. Air-kerma rate and barrier thickness calculations are performed by implementing NCRP Report 147 formalism into a Graphical User Interface (GUI). The ultimate aim of this newly created software package is to reduce errors and improve radiographic and fluoroscopic room designs over manual approaches. Methods: Floor plans are first imported as images into the RadShield software program. These plans serve as templates for drawing barriers, occupied regions and x-ray tube locations. We have implemented sub-GUIs that allow the specification in regions and equipment for occupancy factors, design goals, number of patients, primary beam directions, source-to-patient distances and workload distributions. Once the user enters the above parameters, the program automatically calculates air-kerma rate at sampled points beyond all barriers. For each sample point, a corresponding minimum barrier thickness is calculated to meet the design goal. RadShield allows control over preshielding, sample point location and material types. Results: A functional GUI package was developed and tested. Examination of sample walls and source distributions yields a maximum percent difference of less than 0.1% between hand-calculated air-kerma rates and RadShield. Conclusion: The initial results demonstrated that RadShield calculates air-kerma rates and required barrier thicknesses with reliable accuracy and can be used to make radiation shielding design more efficient and accurate. This newly developed approach differs from conventional calculation methods in that it finds air-kerma rates and thickness requirements for many points outside the barriers, stores the information and selects the largest value needed to comply with NCRP Report 147 design goals. Floor plans, parameters, designs and reports can be saved and accessed later for modification and recalculation

  6. Calculation of the effective environmental dose rate for ESR and luminescence dating

    International Nuclear Information System (INIS)

    Brennan, B.J.

    2001-01-01

    The determination of the age of a sample using luminescence and ESR dating techniques requires knowledge of the sample's average effective environmental dose rate due to natural radiation sources (alpha, beta, gamma, and cosmic), and age estimates can never be more accurate than the estimate of this dose rate. The estimation process is often complicated by spatial and temporal inhomogeneities in the distribution of natural radiation sources. This paper discusses applications of radiation physics in modelling the effects of these inhomogeneities to ensure accurate estimation of the average dose rate for the sample. For natural alpha, beta, and gamma sources, 'dose point kernels' are employed in calculations using an assumed model for the spatial and temporal dependence of source concentrations. These three types of radiation have rather different penetration properties, with their typical effective ranges being multiples of 10 micrometre, 1 mm, and 100 mm respectively. For each type of radiation, applications are discussed where spatial inhomogeneity in the distribution of sources around and in a sample has a serious effect on the average dose rate to the sample. In some cases, (e.g. gamma dose estimation in 'lumpy' environments) lack of detailed knowledge precludes accurate modelling of the site for a particular sample, but useful statistical information can still be obtained. Temporal variation of radioactive source concentrations is usually coupled with spatial effects and can arise from processes such as parent-daughter disequilibrium, uptake or leaching of sources, or variation in burial depth or water saturation. Again, calculations based non a known or assumed history can be employed to obtain a time-averaged dose rate for a sample. The accuracy with which these calculations can reflect the true environmental dose rate is limited principally by the reliability of the model assumed, which in turn depends on the state of knowledge of the site and its history

  7. Single event upset studies on the CMS tracker APV25 readout chip

    International Nuclear Information System (INIS)

    Noah, E.; Bauer, T.; Bisello, D.; Faccio, F.; Friedl, M.; Fulcher, J.R.; Hall, G.; Huhtinen, M.; Kaminsky, A.; Pernicka, M.; Raymond, M.; Wyss, J.

    2002-01-01

    The microstrip tracker for the CMS experiment at the CERN Large Hadron Collider will be read out using APV25 chips. During high luminosity running the tracker will be exposed to particle fluxes up to 10 7 cm -2 s -1 , which raises concerns that the APV25 could occasionally suffer Single Event Upsets (SEUs). The effect of SEU on the APV25 has been studied to investigate implications for CMS detector operation and from the viewpoint of detailed circuit operation, to improve the understanding of its origin and what factors affect its magnitude. Simulations were performed to reconstruct the effects created by highly ionising particles striking sensitive parts of the circuits, along with consideration of the underlying mechanisms of charge deposition, collection and the consequences. A model to predict the behaviour of the memory circuits in the APV25 has been developed and data collected from dedicated experiments using both heavy ions and hadrons have been shown to support it

  8. Results of Propellant Mixing Variable Study Using Precise Pressure-Based Burn Rate Calculations

    Science.gov (United States)

    Stefanski, Philip L.

    2014-01-01

    A designed experiment was conducted in which three mix processing variables (pre-curative addition mix temperature, pre-curative addition mixing time, and mixer speed) were varied to estimate their effects on within-mix propellant burn rate variability. The chosen discriminator for the experiment was the 2-inch diameter by 4-inch long (2x4) Center-Perforated (CP) ballistic evaluation motor. Motor nozzle throat diameters were sized to produce a common targeted chamber pressure. Initial data analysis did not show a statistically significant effect. Because propellant burn rate must be directly related to chamber pressure, a method was developed that showed statistically significant effects on chamber pressure (either maximum or average) by adjustments to the process settings. Burn rates were calculated from chamber pressures and these were then normalized to a common pressure for comparative purposes. The pressure-based method of burn rate determination showed significant reduction in error when compared to results obtained from the Brooks' modification of the propellant web-bisector burn rate determination method. Analysis of effects using burn rates calculated by the pressure-based method showed a significant correlation of within-mix burn rate dispersion to mixing duration and the quadratic of mixing duration. The findings were confirmed in a series of mixes that examined the effects of mixing time on burn rate variation, which yielded the same results.

  9. Condensation and dissociation rates for gas phase metal clusters from molecular dynamics trajectory calculations

    Science.gov (United States)

    Yang, Huan; Goudeli, Eirini; Hogan, Christopher J.

    2018-04-01

    In gas phase synthesis systems, clusters form and grow via condensation, in which a monomer binds to an existing cluster. While a hard-sphere equation is frequently used to predict the condensation rate coefficient, this equation neglects the influences of potential interactions and cluster internal energy on the condensation process. Here, we present a collision rate theory-molecular dynamics simulation approach to calculate condensation probabilities and condensation rate coefficients. We use this approach to examine atomic condensation onto 6-56-atom Au and Mg clusters. The probability of condensation depends upon the initial relative velocity (v) between atom and cluster and the initial impact parameter (b). In all cases, there is a well-defined region of b-v space where condensation is highly probable, and outside of which the condensation probability drops to zero. For Au clusters with more than 10 atoms, we find that at gas temperatures in the 300-1200 K range, the condensation rate coefficient exceeds the hard-sphere rate coefficient by a factor of 1.5-2.0. Conversely, for Au clusters with 10 or fewer atoms and for 14- and 28-atom Mg clusters, as cluster equilibration temperature increases, the condensation rate coefficient drops to values below the hard-sphere rate coefficient. Calculations also yield the self-dissociation rate coefficient, which is found to vary considerably with gas temperature. Finally, calculations results reveal that grazing (high b) atom-cluster collisions at elevated velocity (>1000 m s-1) can result in the colliding atom rebounding (bounce) from the cluster surface or binding while another atom dissociates (replacement). The presented method can be applied in developing rate equations to predict material formation and growth rates in vapor phase systems.

  10. Steady-State Flammable Gas Release Rate Calculation And Lower Flammability Level Evaluation For Hanford Tank Waste

    International Nuclear Information System (INIS)

    Hu, T.A.

    2007-01-01

    Assess the steady-state flammability level at normal and off-normal ventilation conditions. The methodology of flammability analysis for Hanford tank waste is developed. The hydrogen generation rate model was applied to calculate the gas generation rate for 177 tanks. Flammability concentrations and the time to reach 25% and 100% of the lower flammability limit, and the minimum ventilation rate to keep from 100 of the LFL are calculated for 177 tanks at various scenarios.

  11. Standard practice for calculation of corrosion rates and related information from electrochemical measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1989-01-01

    1.1 This practice covers the providing of guidance in converting the results of electrochemical measurements to rates of uniform corrosion. Calculation methods for converting corrosion current density values to either mass loss rates or average penetration rates are given for most engineering alloys. In addition, some guidelines for converting polarization resistance values to corrosion rates are provided. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  12. Calculation of nuclide inventory, decay power, activity and dose rates for spent nuclear fuel

    International Nuclear Information System (INIS)

    Haakansson, Rune

    2000-03-01

    The nuclide inventory was calculated for a BWR and a PWR fuel element, with burnups of 38 and 55 MWd/kg uranium for the BWR fuel, and 42 and 60 MWd/kg uranium for the PWR fuel. The calculations were performed for decay times of up to 300,000 years. Gamma and neutron dose rates have been calculated at a distance of 1 m from a bare fuel element and outside the spent fuel canister. The calculations were performed using the CASMO-4 code

  13. Assessments of fluid friction factors for use in leak rate calculations

    Energy Technology Data Exchange (ETDEWEB)

    Chivers, T.C. [Berkeley Technology Centre, Glos (United Kingdom)

    1997-04-01

    Leak before Break procedures require estimates of leakage, and these in turn need fluid friction to be assessed. In this paper available data on flow rates through idealized and real crack geometries are reviewed in terms of a single friction factor k It is shown that for {lambda} < 1 flow rates can be bounded using correlations in terms of surface R{sub a} values. For {lambda} > 1 the database is less precise, but {lambda} {approx} 4 is an upper bound, hence in this region flow calculations can be assessed using 1 < {lambda} < 4.

  14. Calculations radiobiological using the quadratic lineal model in the use of the medium dose rate absorbed in brachytherapy. Pt. 3

    International Nuclear Information System (INIS)

    2002-01-01

    Calculations with the quadratic lineal model for medium rate using the equation dose-effect. Several calculations for system of low dose rate brachytherapy plus teletherapy, calculations for brachytherapy with medium dose rate together with teletherapy, dose for fraction and the one numbers of fractions in medium rate

  15. A relation between calculated human body exergy consumption rate and subjectively assessed thermal sensation

    DEFF Research Database (Denmark)

    Simone, Angela; Kolarik, Jakub; Iwamatsu, Toshiya

    2011-01-01

    occupants, it is reasonable to consider both the exergy flows in building and those within the human body. Until now, no data have been available on the relation between human-body exergy consumption rates and subjectively assessed thermal sensation. The objective of the present work was to relate thermal...... sensation data, from earlier thermal comfort studies, to calculated human-body exergy consumption rates. The results show that the minimum human body exergy consumption rate is associated with thermal sensation votes close to thermal neutrality, tending to the slightly cool side of thermal sensation....... Generally, the relationship between air temperature and the exergy consumption rate, as a first approximation, shows an increasing trend. Taking account of both convective and radiative heat exchange between the human body and the surrounding environment by using the calculated operative temperature, exergy...

  16. Calculation of the ingestion critical dose rate for the Goiania radioactive waste repository

    International Nuclear Information System (INIS)

    Passos, E.M. dos; Martin Alves, A.S. De

    1994-01-01

    The calculation results of the critical distance for the ingestion dose rate due to a hypothetical Cs-137 release from the Abadia de Goias repository are shown. The work is based on the pathway repository-aquifer-well food chain. The calculations were based upon analytical models for the migration of radioisotopes through the aquifer and for its transfer from well water to food. (author)

  17. Divided Saddle Theory: A New Idea for Rate Constant Calculation.

    Science.gov (United States)

    Daru, János; Stirling, András

    2014-03-11

    We present a theory of rare events and derive an algorithm to obtain rates from postprocessing the numerical data of a free energy calculation and the corresponding committor analysis. The formalism is based on the division of the saddle region of the free energy profile of the rare event into two adjacent segments called saddle domains. The method is built on sampling the dynamics within these regions: auxiliary rate constants are defined for the saddle domains and the absolute forward and backward rates are obtained by proper reweighting. We call our approach divided saddle theory (DST). An important advantage of our approach is that it requires only standard computational techniques which are available in most molecular dynamics codes. We demonstrate the potential of DST numerically on two examples: rearrangement of alanine-dipeptide (CH3CO-Ala-NHCH3) conformers and the intramolecular Cope reaction of the fluxional barbaralane molecule.

  18. Optimizing Discount Rates: Expressing Preferences for Sustainable Outcomes in Present Value Calculations

    OpenAIRE

    Axelrod, David

    2017-01-01

    This paper describes how the discount rate used in present value calculations expresses the preference for sustainability in decision making, and its implication for sustainable economic growth. In essence, the lower the discount rate, the greater the regard for the future, and the more likely we choose behaviors that lead to long-term sustainability. The theoretical framework combines behavioral economics and holonomics, which involve limitations of regard for the future due to constraints o...

  19. The anti-CO2 tax upsets the automotive fleets management. Car makers must adapt themselves. Deluxe cars spared. Small and medium size companies tempted by the long duration rental. At Biogen, medical visitors chose their vehicle

    International Nuclear Information System (INIS)

    Larmor, P.

    2006-01-01

    Since the beginning of the year 2006, the pollution level is now taken into consideration in the calculation of the society vehicles tax. This measure completely upsets the management and allocation rules of provided cars. Therefore, the government foresees to relax its position. Car makers will have to propose new versions of their models with pollution levels in agreement with the tax categories imposed by the new regulation. Small and medium size companies are now tempted by long duration car rental contracts. Therefore, car rental companies foresee interesting opportunities with this fiscality stiffening. This press-kit analyzes the situation from the different points of view: fleet managers, car makers, users, company managers, car hirers. (J.S.)

  20. NAC-1 cask dose rate calculations for LWR spent fuel

    International Nuclear Information System (INIS)

    CARLSON, A.B.

    1999-01-01

    A Nuclear Assurance Corporation nuclear fuel transport cask, NAC-1, is being considered as a transport and storage option for spent nuclear fuel located in the B-Cell of the 324 Building. The loaded casks will be shipped to the 200 East Area Interim Storage Area for dry interim storage. Several calculations were performed to assess the photon and neutron dose rates. This report describes the analytical methods, models, and results of this investigation

  1. Some considerations of ''cold fusion'' including the calculation of fusion rates in molecules of hydrogen isotopes

    International Nuclear Information System (INIS)

    Cowley, S.C.; Kulsrud, R.M.

    1989-11-01

    We calculate the fusion reaction rates in molecules of hydrogen isotopes. The rates are calculated analytically (for the first time) as an asymptotic expansion in the ratio of the electron mass to the reduced mass of the nucleii. The fusion rates of the P-D, D-D, and D-T reactions are given for a variable electron mass by a simple analytic formula. However, we do not know any mechanism by which a sufficiently localized electron in solid can have an 'effective mass' large enough to explain the result of Fleischman and Pons (FP). This calculation indicates that P-D rates should exceed D-D rates for D-D fusion rates less than approximately 10 -23 per molecule per second. The D-D fusion rate is enhanced by a factor of 10 5 at 10,000 degree K if the excited vibrational states are populated with a Boltzmann distribution and the rotational excitations suppressed. The suggestion that experimental results could be explained by bombardment of cold deuterons by kilovolt deuterons is shown to be an unlikely from an energetic point of view. 12 refs., 3 figs., 1 tab

  2. Effects of Cabin Upsets on Adsorption Columns for Air Revitalization

    Science.gov (United States)

    LeVan, Douglas

    1999-01-01

    The National Aeronautics and Space Administration (NASA) utilizes adsorption technology as part of contaminant removal systems designed for long term missions. A variety of trace contaminants can be effectively removed from gas streams by adsorption onto activated carbon. An activated carbon adsorption column meets NASA's requirements of a lightweight and efficient means of controlling trace contaminant levels aboard spacecraft and space stations. The activated carbon bed is part of the Trace Contaminant Control System (TCCS) which is utilized to purify the cabin atmosphere. TCCS designs oversize the adsorption columns to account for irregular fluctuations in cabin atmospheric conditions. Variations in the cabin atmosphere include changes in contaminant concentrations, temperature, and relative humidity. Excessively large deviations from typical conditions can result from unusual crew activity, equipment malfunctions, or even fires. The research carried out under this award focussed in detail on the effects of cabin upsets on the performance of activated carbon adsorption columns. Both experiments and modeling were performed with an emphasis on the roll of a change in relative humidity on adsorption of trace contaminants. A flow through fixed-bed apparatus was constructed at the NASA Ames Research Center, and experiments were performed there. Modeling work was performed at the University of Virginia.

  3. Preliminary calculations of release rates from spent fuel in a tuff repository

    International Nuclear Information System (INIS)

    Apted, M.J.; O'Connell, W.J.; Lee, K.H.; MacIntyre, A.T.; Ueng, T.S.; Pigford, T.H.; Lee, W.W.L.

    1991-01-01

    Time-dependent release rates of Tc-99, I-129, Cs-135, and Np-237 have been calculated for wet-drip and moist-continuous release modes from the engineered barrier system of a potential nuclear waste repository in unsaturated tuff, representative of a possible repository at Yucca Mountain in southern Nevada. We describe the modes of water contact and of release of dissolved radionuclides to the surrounding intact rock, and the corresponding calculational models. We list the parameter values adopted, and then present numerical results, conclusions, and recommendations. 21 refs., 5 figs., 2 tabs

  4. Panthere V2: Multipurpose Simulation Software for 3D Dose Rate Calculations

    Science.gov (United States)

    Penessot, Gaël; Bavoil, Éléonore; Wertz, Laurent; Malouch, Fadhel; Visonneau, Thierry; Dubost, Julien

    2017-09-01

    PANTHERE is a multipurpose radiation protection software developed by EDF to calculate gamma dose rates in complex 3D environments. PANTHERE takes a key role in the EDF ALARA process, enabling to predict dose rates and to organize and optimize operations in high radiation environments. PANTHERE is also used for nuclear waste characterization, transport of nuclear materials, etc. It is used in most of the EDF engineering units and their design service providers and industrial partners.

  5. Heavy Ion SEU Cross Section Calculation Based on Proton Experimental Data, and Vice Versa

    CERN Document Server

    Wrobel, F; Pouget, V; Dilillo, L; Ecoffet, R; Lorfèvre, E; Bezerra, F; Brugger, M; Saigné, F

    2014-01-01

    The aim of this work is to provide a method to calculate single event upset (SEU) cross sections by using experimental data. Valuable tools such as PROFIT and SIMPA already focus on the calculation of the proton cross section by using heavy ions cross-section experiments. However, there is no available tool that calculates heavy ion cross sections based on measured proton cross sections with no knowledge of the technology. We based our approach on the diffusion-collection model with the aim of analyzing the characteristics of transient currents that trigger SEUs. We show that experimental cross sections could be used to characterize the pulses that trigger an SEU. Experimental results allow yet defining an empirical rule to identify the transient current that are responsible for an SEU. Then, the SEU cross section can be calculated for any kind of particle and any energy with no need to know the Spice model of the cell. We applied our method to some technologies (250 nm, 90 nm and 65 nm bulk SRAMs) and we sho...

  6. Single event upset mitigation techniques for FPGAs utilized in nuclear power plant digital instrumentation and control

    International Nuclear Information System (INIS)

    Wang Xin; Holbert, Keith E.; Clark, Lawrence T.

    2011-01-01

    Highlights: → Triple modular redundancy (TMR) implementation is the best solution for digital I and C. → Maximal probability of two simultaneous errors with TMR maximum partition is 4.44%. → Dual modular redundancy minimum logic partitioning design is an additional option. - Abstract: Field programmable gate arrays (FPGAs) are integrated circuits being increasingly used for digital instrumentation and control (I and C) in nuclear power plants (NPPs) because of low cost, re-configurability and low design turn-around time. However, to ensure reliability, proper design techniques must be employed since the memory and logic in FPGAs are susceptible to single event upsets (SEUs). Triple modular redundancy (TMR) has become a common SEU mitigation design technique because of its straightforward implementation and reliable results. Partitioned TMR approaches are introduced in this paper, and formulae derived indicate that the maximum probability of two simultaneous errors [P E ] max is inversely proportional to the number of logic partitions in a TMR design, when each redundant logic block in every logic partition has the same number of sensitive nodes. However, the maximum logic partitioning design cannot completely eliminate the possibility of two simultaneous upsets. For the example test circuit it is found that [P E ] max is reduced dramatically from 66.67% for minimum logic partitioning to 4.44% for maximum logic partitioning. Because TMR introduces significant overhead due to its full hardware redundancy, a dual modular redundancy approach is also examined for application to less demanding situations. By comparative analysis this study reaches the conclusion that the maximum logic partitioning TMR implementation is the best solution for digital I and C applications in NPPs where obtaining robustness is of the highest importance, despite its higher area overhead.

  7. A Novel Application of Machine Learning Methods to Model Microcontroller Upset Due to Intentional Electromagnetic Interference

    Science.gov (United States)

    Bilalic, Rusmir

    A novel application of support vector machines (SVMs), artificial neural networks (ANNs), and Gaussian processes (GPs) for machine learning (GPML) to model microcontroller unit (MCU) upset due to intentional electromagnetic interference (IEMI) is presented. In this approach, an MCU performs a counting operation (0-7) while electromagnetic interference in the form of a radio frequency (RF) pulse is direct-injected into the MCU clock line. Injection times with respect to the clock signal are the clock low, clock rising edge, clock high, and the clock falling edge periods in the clock window during which the MCU is performing initialization and executing the counting procedure. The intent is to cause disruption in the counting operation and model the probability of effect (PoE) using machine learning tools. Five experiments were executed as part of this research, each of which contained a set of 38,300 training points and 38,300 test points, for a total of 383,000 total points with the following experiment variables: injection times with respect to the clock signal, injected RF power, injected RF pulse width, and injected RF frequency. For the 191,500 training points, the average training error was 12.47%, while for the 191,500 test points the average test error was 14.85%, meaning that on average, the machine was able to predict MCU upset with an 85.15% accuracy. Leaving out the results for the worst-performing model (SVM with a linear kernel), the test prediction accuracy for the remaining machines is almost 89%. All three machine learning methods (ANNs, SVMs, and GPML) showed excellent and consistent results in their ability to model and predict the PoE on an MCU due to IEMI. The GP approach performed best during training with a 7.43% average training error, while the ANN technique was most accurate during the test with a 10.80% error.

  8. Benchmark calculations for evaluation methods of gas volumetric leakage rate

    International Nuclear Information System (INIS)

    Asano, R.; Aritomi, M.; Matsuzaki, M.

    1998-01-01

    A containment function of radioactive materials transport casks is essential for safe transportation to prevent the radioactive materials from being released into environment. Regulations such as IAEA standard determined the limit of radioactivity to be released. Since is not practical for the leakage tests to measure directly the radioactivity release from a package, as gas volumetric leakages rates are proposed in ANSI N14.5 and ISO standards. In our previous works, gas volumetric leakage rates for several kinds of gas from various leaks were measured and two evaluation methods, 'a simple evaluation method' and 'a strict evaluation method', were proposed based on the results. The simple evaluation method considers the friction loss of laminar flow with expansion effect. The strict evaluating method considers an exit loss in addition to the friction loss. In this study, four worked examples were completed for on assumed large spent fuel transport cask (Type B Package) with wet or dry capacity and at three transport conditions; normal transport with intact fuels or failed fuels, and an accident in transport. The standard leakage rates and criteria for two kinds of leak test were calculated for each example by each evaluation method. The following observations are made based upon the calculations and evaluations: the choked flow model of ANSI method greatly overestimates the criteria for tests ; the laminar flow models of both ANSI and ISO methods slightly overestimate the criteria for tests; the above two results are within the design margin for ordinary transport condition and all methods are useful for the evaluation; for severe condition such as failed fuel transportation, it should pay attention to apply a choked flow model of ANSI method. (authors)

  9. A novel back-up control structure to manage nonroutine steam upsets in industrial methanol distillation columns

    DEFF Research Database (Denmark)

    Udugama, Isuru A.; Zander, Cornina; Mansouri, Seyed Soheil

    2017-01-01

    Industrial methanol production plants have extensive heat integration to achieve energy efficient operations where steam generated from these heat integration operations are used to provide reboiler duty for methanol distillation columns that purify crude methanol produced into industrial AA grade...... supervisory layer to control the column during these non-routine process upsets. These control schemes were tested against realistic reboiler duty disturbances that can occur in an industrial process. The tests revealed that both the MPC and supervisory systems control structures are able to regulate...... the process, even during sudden drops in reboiler duty. However, the cost of implementation and the relative simplicity will likely favour the implementation of the supervisory control structure in an industrial environment....

  10. Error rate of automated calculation for wound surface area using a digital photography.

    Science.gov (United States)

    Yang, S; Park, J; Lee, H; Lee, J B; Lee, B U; Oh, B H

    2018-02-01

    Although measuring would size using digital photography is a quick and simple method to evaluate the skin wound, the possible compatibility of it has not been fully validated. To investigate the error rate of our newly developed wound surface area calculation using digital photography. Using a smartphone and a digital single lens reflex (DSLR) camera, four photographs of various sized wounds (diameter: 0.5-3.5 cm) were taken from the facial skin model in company with color patches. The quantitative values of wound areas were automatically calculated. The relative error (RE) of this method with regard to wound sizes and types of camera was analyzed. RE of individual calculated area was from 0.0329% (DSLR, diameter 1.0 cm) to 23.7166% (smartphone, diameter 2.0 cm). In spite of the correction of lens curvature, smartphone has significantly higher error rate than DSLR camera (3.9431±2.9772 vs 8.1303±4.8236). However, in cases of wound diameter below than 3 cm, REs of average values of four photographs were below than 5%. In addition, there was no difference in the average value of wound area taken by smartphone and DSLR camera in those cases. For the follow-up of small skin defect (diameter: <3 cm), our newly developed automated wound area calculation method is able to be applied to the plenty of photographs, and the average values of them are a relatively useful index of wound healing with acceptable error rate. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Texture evolution in upset-forged P/M and wrought tantalum: Experimentation and modeling

    International Nuclear Information System (INIS)

    Bingert, J.F.; Desch, P.B.; Bingert, S.R.; Maudlin, P.J.; Tome, C.N.

    1997-11-01

    Preferred orientations in polycrystalline materials can significantly affect their physical and mechanical response through the retention of anisotropic properties inherent to the single crystal. In this study the texture evolution in upset-forged PIM and wrought tantalum was measured as a function of initial texture, compressive strain, and relative position in the pressing. A / duplex fiber texture parallel to the compression axis was generally observed, with varying degrees of a radial component evident in the wrought material. The development of deformation textures derives from restricted crystallographic slip conditions that generate lattice rotations, and these grain reorientations can be modeled as a function of the prescribed deformation gradient. Texture development was simulated for equivalent deformations using both a modified Taylor approach and a viscoplastic self-consistent (VPSC) model. A comparison between the predicted evolution and experimental results shows a good correlation with the texture components, but an overly sharp prediction at large strains from both the Taylor and VPSC models

  12. Synergistic effects of total ionizing dose on single event upset sensitivity in static random access memory under proton irradiation

    International Nuclear Information System (INIS)

    Xiao Yao; Guo Hong-Xia; Zhang Feng-Qi; Zhao Wen; Wang Yan-Ping; Zhang Ke-Ying; Ding Li-Li; Luo Yin-Hong; Wang Yuan-Ming; Fan Xue

    2014-01-01

    Synergistic effects of the total ionizing dose (TID) on the single event upset (SEU) sensitivity in static random access memories (SRAMs) were studied by using protons. The total dose was cumulated with high flux protons during the TID exposure, and the SEU cross section was tested with low flux protons at several cumulated dose steps. Because of the radiation-induced off-state leakage current increase of the CMOS transistors, the noise margin became asymmetric and the memory imprint effect was observed. (interdisciplinary physics and related areas of science and technology)

  13. Monte Carlo calculation of dose rate conversion factors for external exposure to photon emitters in soil

    CERN Document Server

    Clouvas, A; Antonopoulos-Domis, M; Silva, J

    2000-01-01

    The dose rate conversion factors D/sub CF/ (absorbed dose rate in air per unit activity per unit of soil mass, nGy h/sup -1/ per Bq kg/sup -1/) are calculated 1 m above ground for photon emitters of natural radionuclides uniformly distributed in the soil. Three Monte Carlo codes are used: 1) The MCNP code of Los Alamos; 2) The GEANT code of CERN; and 3) a Monte Carlo code developed in the Nuclear Technology Laboratory of the Aristotle University of Thessaloniki. The accuracy of the Monte Carlo results is tested by the comparison of the unscattered flux obtained by the three Monte Carlo codes with an independent straightforward calculation. All codes and particularly the MCNP calculate accurately the absorbed dose rate in air due to the unscattered radiation. For the total radiation (unscattered plus scattered) the D/sub CF/ values calculated from the three codes are in very good agreement between them. The comparison between these results and the results deduced previously by other authors indicates a good ag...

  14. Results of a bench mark test on the crack opening and leak rate calculation

    International Nuclear Information System (INIS)

    Grebner, H.

    1995-01-01

    Results of a bench mark test on the standard problem calculation of crack opening and leak rate in piping components are presented. The bench mark test is based on two experiments performed in phase III of the German HDR safety program. The pipe sections considered in these experiments were a straight pipe with an 80 mm diameter containing a circumferential wall penetrating crack and a pipe branch DN 100/DN 25 with a crack in the weldment between the nozzle and the main pipe. Both test pieces were made of austenitic steel and were loaded by internal pressure and bending moment. For the evaluation of the crack opening either analytical methods or estimation schemes or the finite element method were used, while leak rates were calculated by means of two-phase flow methods. The compilation of the results shows very large scatter bands in general, with deviations between calculated and measured values of up to some one hundred percent. Reasons for this behaviour are uncertainties in the measured data and their evaluation as well as the different methods of calculation and their uncertainties. (author)

  15. Direct quantum mechanical calculation of the F + H{sub 2} {yields} HF + H thermal rate constant

    Energy Technology Data Exchange (ETDEWEB)

    Moix, Marc [Computer Simulation and Modeling (COSMO) Lab, Parc Cientific de Barcelona, Josep Samitier 5, 08028 Barcelona (Spain); Institut de Quimica Teorica i Computacional de la UB (IQTCUB), Universitat de Barcelona (Spain); Huarte-Larranaga, Fermin [Computer Simulation and Modeling (COSMO) Lab, Parc Cientific de Barcelona, Josep Samitier 5, 08028 Barcelona (Spain); Institut de Quimica Teorica i Computacional de la UB (IQTCUB), Universitat de Barcelona (Spain)], E-mail: fhuarte@pcb.ub.es

    2008-07-03

    Accurate full-dimensional quantum mechanical thermal rate constant values have been calculated for the F+H{sub 2}{yields}HF+H reaction on the Stark-Werner ab initio potential energy surface. These calculations are based on a flux correlation functions and employ a rigorous statistical sampling scheme to account for the overall rotation and the MCTDH scheme for the wave packet propagation. Our results shed some light on discrepancies on the thermal rate found for previous flux correlation based calculations with respect to accurate reactive scattering results. The resonance pattern of the all-J cumulative reaction probability is analyzed in terms of the partial wave contributions.

  16. MCNPCX calculations of dose rates and spectra in experimental channels of the CTEx irradiating facility

    International Nuclear Information System (INIS)

    Gomes, Renato G.; Rebello, Wilson F.; Vellozo, Sergio O.; Junior, Luis M.; Vital, Helio C.; Rusin, Tiago; Silva, Ademir X.

    2013-01-01

    MCNPX simulations have been performed in order to calculate dose rates as well as spectra along the four experimental channels of the gamma irradiating facility at the Technology Center of the Brazilian Army (CTEx). Safety, operational and research requirements have led to the need to determine both the magnitude and spectra of the leaking gamma fluxes. The CTEx experimental facility is cavity type with a moveable set of 28 horizontally positioned rods, filled with Cesium-137 chloride and doubly encased in stainless steel that yields an approximately plane 42 kCi-source that provides a maximum dose rate of about 1.5 kG/h into two irradiating chambers. The channels are intended for irradiation tests outside facility. They would allow larger samples to be exposed to lower gamma dose rates under controlled conditions. Dose rates have been calculated for several positions inside the channels as well as at their exits. In addition, for purposes related to the safety of operators and personnel, the angles submitted by the exiting beams have also been evaluated as they spread when leaving the channels. All calculations have been performed by using a computational model of the CTEx facility that allows its characteristics and operation to be accurately simulated by using the Monte Carlo Method. Virtual dosimeters filled with Fricke (ferrous sulfate) were modeled and positioned throughout 2 vertical channels (top and bottom) and 2 horizontal ones (front and back) in order to map dose rates and gamma spectrum distributions. The calculations revealed exiting collimated beams in the order of tenths of Grays per minute as compared to the maximum 25 Gy / min dose rate in the irradiator chamber. In addition, the beams leaving the two vertical channels were found to exhibit a widespread cone-shaped distribution with aperture angle ranging around 85 deg. The data calculated in this work are intended for use in the design of optimized experiments (better positioning of samples and

  17. External dose-rate conversion factors for calculation of dose to the public

    Energy Technology Data Exchange (ETDEWEB)

    1988-07-01

    This report presents a tabulation of dose-rate conversion factors for external exposure to photons and electrons emitted by radionuclides in the environment. This report was prepared in conjunction with criteria for limiting dose equivalents to members of the public from operations of the US Department of Energy (DOE). The dose-rate conversion factors are provided for use by the DOE and its contractors in performing calculations of external dose equivalents to members of the public. The dose-rate conversion factors for external exposure to photons and electrons presented in this report are based on a methodology developed at Oak Ridge National Laboratory. However, some adjustments of the previously documented methodology have been made in obtaining the dose-rate conversion factors in this report. 42 refs., 1 fig., 4 tabs.

  18. Evolution of microstructure and texture in copper during repetitive extrusion-upsetting and subsequent annealing

    DEFF Research Database (Denmark)

    Chen, Q.; Shu, D. Y.; Lin, J.

    2017-01-01

    The evolution of the microstructure and texture in copper has been studied during repetitive extrusion-upsetting (REU) to a total von Mises strain of 4.7 and during subsequent annealing at different temperatures. It is found that the texture is significantly altered by each deformation pass...... strain of 4.7 is measured to be ∼0.3μm. This refined microstructure is unstable at room temperature as is evident from the presence of a small number of recrystallized grains in the deformed matrix. Pronounced recrystallization took place during annealing at 200 °C for 1 h with recrystallized grains...... developing predominantly in high misorientation regions. At 350 ºC the microstructure is fully recrystallized with an average grain size of only 2.3 μm and a very weak crystallographic texture. This REU-processed and subsequently annealed material is considered to be potentially suitable for using...

  19. Evaluation of single-event upset tolerance on 64Mbit DRAM and 16Mbit DRAM

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, N; Shindou, H; Matsuzaki, K; Akutsu, T; Matsuda, S [National Space Development Agency of Japan, Tokyo (Japan); Hirao, T; Itoh, H; Nashiyama, I

    1997-11-01

    In recent years, reduction in the mission cost is regarded as one of the most important matters, and thus much effort has been made to reduce the cost of electronic components used in spacecrafts without diminishing their performance. On this policy, there has been a growing interest in space application of commercial devices such as highly integrated memory ICs because of low prices and high performance of such devices. To ensure success in this application, it is indispensable to investigate radiation effects, e.g., single-event and total-dose effects, on commercial devices precisely. In the present study, we have evaluated single-event upset (SEU) tolerance for 1Mbit, 4Mbit SRAM and 16Mbit, 64Mbit DRAM by irradiation of high energy heavy ions such as 175MeV-Ar{sup 8+} and 450MeV-Xe{sup 23+}. We observed these SEU tolerance in space. (author)

  20. A Monte Carlo program to calculate the exposure rate from airborne radioactive gases inside a nuclear reactor containment building.

    Science.gov (United States)

    Sherbini, S; Tamasanis, D; Sykes, J; Porter, S W

    1986-12-01

    A program was developed to calculate the exposure rate resulting from airborne gases inside a reactor containment building. The calculations were performed at the location of a wall-mounted area radiation monitor. The program uses Monte Carlo techniques and accounts for both the direct and scattered components of the radiation field at the detector. The scattered component was found to contribute about 30% of the total exposure rate at 50 keV and dropped to about 7% at 2000 keV. The results of the calculations were normalized to unit activity per unit volume of air in the containment. This allows the exposure rate readings of the area monitor to be used to estimate the airborne activity in containment in the early phases of an accident. Such estimates, coupled with containment leak rates, provide a method to obtain a release rate for use in offsite dose projection calculations.

  1. Reexamining the Dissolution of Spent Fuel: A Comparison of Different Methods for Calculating Rates

    International Nuclear Information System (INIS)

    Hanson, Brady D.; Stout, Ray B.

    2004-01-01

    Dissolution rates for spent fuel have typically been reported in terms of a rate normalized to the surface area of the specimen. Recent evidence has shown that neither the geometric surface area nor that measured with BET accurately predicts the effective surface area of spent fuel. Dissolution rates calculated from results obtained by flowthrough tests were reexamined comparing the cumulative releases and surface area normalized rates. While initial surface area is important for comparison of different rates, it appears that normalizing to the surface area introduces unnecessary uncertainty compared to using cumulative or fractional release rates. Discrepancies in past data analyses are mitigated using this alternative method

  2. Expanded calculation of weak-interaction-mediated neutrino cooling rates due to 56Ni in stellar matter

    International Nuclear Information System (INIS)

    Nabi, Jameel-Un

    2010-01-01

    An accurate estimate of the neutrino cooling rates is required in order to study the various stages of stellar evolution of massive stars. Neutrino losses from proto-neutron stars play a crucial role in deciding whether these stars would be crushed into black holes or explode as supernovae. Both pure leptonic and weak-interaction processes contribute to the neutrino energy losses in stellar matter. At low temperatures and densities, the characteristics of the early phase of presupernova evolution, cooling through neutrinos produced via the weak interaction, are important. Proton-neutron quasi-particle random phase approximation (pn-QRPA) theory has recently been used with success for the calculation of stellar weak-interaction rates of fp-shell nuclide. The lepton-to-baryon ratio (Y e ) during early phases of stellar evolution of massive stars changes substantially, mainly due to electron captures on 56 Ni. The stellar matter is transparent to the neutrinos produced during the presupernova evolution of massive stars. These neutrinos escape the site and assist the stellar core in maintaining a lower entropy. Here, an expanded calculation of weak-interaction-mediated neutrino and antineutrino cooling rates due to 56 Ni in stellar matter using the pn-QRPA theory is presented. This detailed scale is appropriate for interpolation purposes and is of greater utility for simulation codes. The calculated rates are compared with earlier calculations. During the relevant temperature and density regions of stellar matter the reported rates show few differences compared with the shell model rates and might contribute in fine-tuning of the lepton-to-baryon ratio during the presupernova phases of stellar evolution of massive stars.

  3. 20 CFR 10.216 - How is the pay rate for COP calculated?

    Science.gov (United States)

    2010-04-01

    ... for COP purposes is equal to the employee's regular “weekly” pay (the average of the weekly pay over... occurred during the 45-day period are to be reflected in the weekly pay determination. (b) The weekly pay... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false How is the pay rate for COP calculated? 10...

  4. A relation between calculated human body exergy consumption rate and subjectively assessed thermal sensation

    Energy Technology Data Exchange (ETDEWEB)

    Simone, Angela; Kolarik, Jakub; Olesen, Bjarne W. [ICIEE/BYG, Technical University of Denmark (Denmark); Iwamatsu, Toshiya [Faculty of Urban Environmental Science, Tokyo Metropolitan University (Japan); Asada, Hideo [Architech Consulting Co., Tokyo (Japan); Dovjak, Mateja [Faculty of Civil and Geodetic Engineering, University of Ljubljana (Slovenia); Schellen, Lisje [Eindhoven University of Technology, Faculty of Architecture Building and Planning (Netherlands); Shukuya, Masanori [Laboratory of Building Environment, Tokyo City University, Yokohama (Japan)

    2011-01-15

    Application of the exergy concept to research on the built environment is a relatively new approach. It helps to optimize climate conditioning systems so that they meet the requirements of sustainable building design. As the building should provide a healthy and comfortable environment for its occupants, it is reasonable to consider both the exergy flows in building and those within the human body. Until now, no data have been available on the relation between human-body exergy consumption rates and subjectively assessed thermal sensation. The objective of the present work was to relate thermal sensation data, from earlier thermal comfort studies, to calculated human-body exergy consumption rates. The results show that the minimum human body exergy consumption rate is associated with thermal sensation votes close to thermal neutrality, tending to the slightly cool side of thermal sensation. Generally, the relationship between air temperature and the exergy consumption rate, as a first approximation, shows an increasing trend. Taking account of both convective and radiative heat exchange between the human body and the surrounding environment by using the calculated operative temperature, exergy consumption rates increase as the operative temperature increases above 24 C or decreases below 22 C. With the data available so far, a second-order polynomial relationship between thermal sensation and the exergy consumption rate was established. (author)

  5. Study on relations between heavy ions single event upset cross sections and γ accumulated doses

    International Nuclear Information System (INIS)

    He Chaohui; Geng Bin; Wang Yanping; Peng Honglun; Yang Hailiang; Chen Xiaohua; Li Guozheng

    2002-01-01

    Experiments were done under 252 Cf and 60 Co γ source to study the relation between heavy ion Single Event Upset (SEU) cross sections and γ accumulated doses. There was no obvious rule and little influence of γ accumulated doses on SEU cross sections when Static Random Access Memories were in power off mode and static power on mode. In active measuring mode, the SEU cross section increased as the accumulated doses increasing when same data were written in memory cells. If reverse data, such as '55' and 'AA', were written in memory cells during the experiment, the SEU cross sections decreased to the level when memories were not irradiated under 60 Co γ source, even more small. It implied that the influence of γ accumulated doses on SEU cross sections can be set off by this method

  6. A modified Gaussian integration method for thermal reaction rate calculation in U- and Pu-isotopes

    International Nuclear Information System (INIS)

    Bosevski, T.; Fredin, B.

    1966-01-01

    An advanced multi-group cell calculations a lot of data information is very often necessary, and hence the data administration will be elaborate, and the spectrum calculation will be time consuming. We think it is possible to reduce the necessary data information by using an effective reaction rate integration method well suited for U- and Pu-absorptions (author)

  7. Electromagnetic Calculation and Plasma Leakage Rate Analysis of the Magnetically Confined Plasma Rocket

    International Nuclear Information System (INIS)

    Ni Zhipeng; Wang Liangbin; Li Jiangang; Chen Zhiyou; Zhang Yong; Wang Futang

    2008-01-01

    An electromagnetic calculation and the parameters of the magnet system of the magnetically confined plasma rocket were established. By using ANSYS code, it was found that the leakage rate depends on the current intensity of the magnet and the change of the magnet position.

  8. Effects of sample size on estimates of population growth rates calculated with matrix models.

    Directory of Open Access Journals (Sweden)

    Ian J Fiske

    Full Text Available BACKGROUND: Matrix models are widely used to study the dynamics and demography of populations. An important but overlooked issue is how the number of individuals sampled influences estimates of the population growth rate (lambda calculated with matrix models. Even unbiased estimates of vital rates do not ensure unbiased estimates of lambda-Jensen's Inequality implies that even when the estimates of the vital rates are accurate, small sample sizes lead to biased estimates of lambda due to increased sampling variance. We investigated if sampling variability and the distribution of sampling effort among size classes lead to biases in estimates of lambda. METHODOLOGY/PRINCIPAL FINDINGS: Using data from a long-term field study of plant demography, we simulated the effects of sampling variance by drawing vital rates and calculating lambda for increasingly larger populations drawn from a total population of 3842 plants. We then compared these estimates of lambda with those based on the entire population and calculated the resulting bias. Finally, we conducted a review of the literature to determine the sample sizes typically used when parameterizing matrix models used to study plant demography. CONCLUSIONS/SIGNIFICANCE: We found significant bias at small sample sizes when survival was low (survival = 0.5, and that sampling with a more-realistic inverse J-shaped population structure exacerbated this bias. However our simulations also demonstrate that these biases rapidly become negligible with increasing sample sizes or as survival increases. For many of the sample sizes used in demographic studies, matrix models are probably robust to the biases resulting from sampling variance of vital rates. However, this conclusion may depend on the structure of populations or the distribution of sampling effort in ways that are unexplored. We suggest more intensive sampling of populations when individual survival is low and greater sampling of stages with high

  9. Effects of sample size on estimates of population growth rates calculated with matrix models.

    Science.gov (United States)

    Fiske, Ian J; Bruna, Emilio M; Bolker, Benjamin M

    2008-08-28

    Matrix models are widely used to study the dynamics and demography of populations. An important but overlooked issue is how the number of individuals sampled influences estimates of the population growth rate (lambda) calculated with matrix models. Even unbiased estimates of vital rates do not ensure unbiased estimates of lambda-Jensen's Inequality implies that even when the estimates of the vital rates are accurate, small sample sizes lead to biased estimates of lambda due to increased sampling variance. We investigated if sampling variability and the distribution of sampling effort among size classes lead to biases in estimates of lambda. Using data from a long-term field study of plant demography, we simulated the effects of sampling variance by drawing vital rates and calculating lambda for increasingly larger populations drawn from a total population of 3842 plants. We then compared these estimates of lambda with those based on the entire population and calculated the resulting bias. Finally, we conducted a review of the literature to determine the sample sizes typically used when parameterizing matrix models used to study plant demography. We found significant bias at small sample sizes when survival was low (survival = 0.5), and that sampling with a more-realistic inverse J-shaped population structure exacerbated this bias. However our simulations also demonstrate that these biases rapidly become negligible with increasing sample sizes or as survival increases. For many of the sample sizes used in demographic studies, matrix models are probably robust to the biases resulting from sampling variance of vital rates. However, this conclusion may depend on the structure of populations or the distribution of sampling effort in ways that are unexplored. We suggest more intensive sampling of populations when individual survival is low and greater sampling of stages with high elasticities.

  10. Small groups, large profits: Calculating interest rates in community-managed microfinance

    DEFF Research Database (Denmark)

    Rasmussen, Ole Dahl

    2012-01-01

    Savings groups are a widely used strategy for women’s economic resilience – over 80% of members worldwide are women, and in the case described here, 72.5%. In these savings groups it is common to see the interest rate on savings reported as "20-30% annually". Using panel data from 204 groups...... in Malawi, I show that the right figure is likely to be at least twice this figure. For these groups, the annual return is 62%. The difference comes from sector-wide application of a non-standard interest rate calculations and unrealistic assumptions about the savings profile in the groups. As a result......, it is impossible to compare returns in savings groups with returns elsewhere. Moreover, the interest on savings is incomparable to the interest rate on loans. I argue for the use of a standardized comparable metric and suggest easy ways to implement it. Developments of new tools and standard along these lines...

  11. A comparative study of different methods for calculating electronic transition rates

    Science.gov (United States)

    Kananenka, Alexei A.; Sun, Xiang; Schubert, Alexander; Dunietz, Barry D.; Geva, Eitan

    2018-03-01

    We present a comprehensive comparison of the following mixed quantum-classical methods for calculating electronic transition rates: (1) nonequilibrium Fermi's golden rule, (2) mixed quantum-classical Liouville method, (3) mean-field (Ehrenfest) mixed quantum-classical method, and (4) fewest switches surface-hopping method (in diabatic and adiabatic representations). The comparison is performed on the Garg-Onuchic-Ambegaokar benchmark charge-transfer model, over a broad range of temperatures and electronic coupling strengths, with different nonequilibrium initial states, in the normal and inverted regimes. Under weak to moderate electronic coupling, the nonequilibrium Fermi's golden rule rates are found to be in good agreement with the rates obtained via the mixed quantum-classical Liouville method that coincides with the fully quantum-mechanically exact results for the model system under study. Our results suggest that the nonequilibrium Fermi's golden rule can serve as an inexpensive yet accurate alternative to Ehrenfest and the fewest switches surface-hopping methods.

  12. Microbeam mapping of single event latchups and single event upsets in CMOS SRAMs

    International Nuclear Information System (INIS)

    Barak, J.; Adler, E.; Fischer, B.E.; Schloegl, M.; Metzger, S.

    1998-01-01

    The first simultaneous microbeam mapping of single event upset (SEU) and latchup (SEL) in the CMOS RAM HM65162 is presented. The authors found that the shapes of the sensitive areas depend on V DD , on the ions being used and on the site on the chip being hit by the ion. In particular, they found SEL sensitive sites close to the main power supply lines between the memory-bit-arrays by detecting the accompanying current surge. All these SELs were also accompanied by bit-flips elsewhere in the memory (which they call indirect SEUs in contrast to the well known SEUs induced in the hit memory cell only). When identical SEL sensitive sites were hit farther away from the supply lines only indirect SEL sensitive sites could be detected. They interpret these events as latent latchups in contrast to the classical ones detected by their induced current surge. These latent SELs were probably decoupled from the main supply lines by the high resistivity of the local supply lines

  13. 78 FR 1222 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2013-01-08

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning January 1, 2013, the interest rates for [[Page 1223

  14. Evaluation of methodologies for the calculation of leak rates for pressure retaining components with crack-like leaks

    International Nuclear Information System (INIS)

    Sievers, Juergen; Heckmann, Klaus; Blaesius, Christoph

    2015-06-01

    For the demonstration of break preclusion for pressure retaining components in nuclear power plants, the nuclear safety standard KTA 3206 determines also the requirements for the leak-before-break verification. For this procedure, it has to be ensured that a wall-penetrating crack is subcritical with respect to instable growth, and that the resulting leakage under stationary operation conditions can be detected by a leak detection system. Within the scope of the project 3613R01332 analyses with respect to conservative estimates of the leak rates in case of detections regarding break preclusion were performed by means of leak rate models being available at GRS. For this purpose, conservative assumptions in the procedure were quantified by comparative calculations concerning selected leak rate experiments and the requirements regarding the determination of leak rates indicated in the KTA 3206 were verified and specified. Moreover, the models were extended and relevant recommendations for the calculation procedure were developed. During the investigations of leak rate tests the calculation methods were validated, qualified by means of both examples indicated in KTA 3206 and applied to a postulated leak accident in the cooling circuit of a PWR. For the calculation of leak rates several simplified solution methods which are included in the GRS program WinLeck were applied, and for the simulation of a leak accident the large-scale programs ANSYS Mechanical and ATHLET (thermohydraulics program developed by GRS) were used. When applying simplified methods for the calculation of leak rates using the limiting curve for the friction factor which has been derived during the project and which is included in the KTA 3206 attention has to be paid to the fact that in case of small flow lengths the entrance loss can dominate compared to the friction loss. However, the available data do not suffice in order to make a quantitative statement with respect to limits of applicability

  15. Calculation of fluence rate distributions in a pre design clinical facility for BNCT at the LFR

    International Nuclear Information System (INIS)

    Peeters, T.T.J.M.; Freudenreich, W.E.

    1995-12-01

    In a previous study [1], it was demonstrated that the creation of a thermal neutron facility for clinical BNCT in the LFR is feasible. Monte Carlo calculations had shown that the neutron fluence rates and gamma dose rates at the detector position of a model representing a first outline of a clinical facility met all requirements that are necessary for clinical BNCT. In order to gain more information about the neutron fluence rates at several positions, a second step is required. Calculations have been performed for the free beam and for a tumour bearing phantom at 5 cm and 10 cm distance from the irradiation window. Due to thermalization and back scattering, the thermal fluence rates in the tumour at 5 and 10 cm distance from the bismuth shield appeared to be approximately twice as high as the thermal fluence rates in the free beam at the corresponding positions of 5 to 6 cm and 10 to 11 cm from the irradiation window. (orig.)

  16. Understanding the biological activity of high rate algae ponds through the calculation of oxygen balances.

    Science.gov (United States)

    Arbib, Zouhayr; de Godos Crespo, Ignacio; Corona, Enrique Lara; Rogalla, Frank

    2017-06-01

    Microalgae culture in high rate algae ponds (HRAP) is an environmentally friendly technology for wastewater treatment. However, for the implementation of these systems, a better understanding of the oxygenation potential and the influence of climate conditions is required. In this work, the rates of oxygen production, consumption, and exchange with the atmosphere were calculated under varying conditions of solar irradiance and dilution rate during six months of operation in a real scale unit. This analysis allowed determining the biological response of these dynamic systems. The rates of oxygen consumption measured were considerably higher than the values calculated based on the organic loading rate. The response to light intensity in terms of oxygen production in the bioreactor was described with one of the models proposed for microalgae culture in dense concentrations. This model is based on the availability of light inside the culture and the specific response of microalgae to this parameter. The specific response to solar radiation intensity showed a reasonable stability in spite of the fluctuations due to meteorological conditions. The methodology developed is a useful tool for optimization and prediction of the performance of these systems.

  17. Experimental validation of calculated capture rate for nucleus involved in fuel cycle

    International Nuclear Information System (INIS)

    Benslimane-Bouland, A.

    1997-01-01

    This work has been realized in the framework of the estimation of actinides and fission products nuclear data for the today and future reactors. The first part presents the existing integral experiments for the calculated capture rate and the methods used in the design of reactor cores calculation formulary. The second part is devoted to the interpretation of three specific irradiation experiments which allow the evaluation of the today knowledge on studied data and their associated uncertainties. The last part presents a synthesis of results and the statistical methods used for the adjustment of data bases. This work shows that, in spite of the reactors Physics progresses on the knowledge of uranium and plutonium capture cross sections, uncertainties remain for minor actinides. (A.L.B.)

  18. 75 FR 20373 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2010-04-19

    ... DEPARTMENT OF HOMELAND SECURITY Customs and Border Protection Quarterly IRS Interest Rates Used in... quarterly Internal Revenue Service interest rates used to calculate interest on overdue accounts..., the interest rates for overpayments will be 3 percent for corporations and 4 percent for non...

  19. 76 FR 64964 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2011-10-19

    ... DEPARTMENT OF HOMELAND SECURITY Customs and Border Protection Quarterly IRS Interest Rates Used in... quarterly Internal Revenue Service interest rates used to calculate interest on overdue accounts..., the interest rates for overpayments will be 2 percent for corporations and 3 percent for non...

  20. 76 FR 2404 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2011-01-13

    ... DEPARTMENT OF HOMELAND SECURITY Customs And Border Protection Quarterly IRS Interest Rates Used in... quarterly Internal Revenue Service interest rates used to calculate interest on overdue accounts..., the interest rates for overpayments will be 2 percent for corporations and 3 percent for non...

  1. High School Diploma Options That Meet Federal Graduation Rate Calculation Requirements. Education Trends

    Science.gov (United States)

    Zinth, Jennifer

    2018-01-01

    Federal requirements stipulate that states and local education agencies annually calculate and report an Adjusted Cohort Graduation Rate, disaggregated by student group. The ACGR includes all students who graduate from high school in four years with a regular high school diploma, plus all students with the most significant cognitive disabilities…

  2. Determining dose rate with a semiconductor detector - Monte Carlo calculations of the detector response

    Energy Technology Data Exchange (ETDEWEB)

    Nordenfors, C

    1999-02-01

    To determine dose rate in a gamma radiation field, based on measurements with a semiconductor detector, it is necessary to know how the detector effects the field. This work aims to describe this effect with Monte Carlo simulations and calculations, that is to identify the detector response function. This is done for a germanium gamma detector. The detector is normally used in the in-situ measurements that is carried out regularly at the department. After the response function is determined it is used to reconstruct a spectrum from an in-situ measurement, a so called unfolding. This is done to be able to calculate fluence rate and dose rate directly from a measured (and unfolded) spectrum. The Monte Carlo code used in this work is EGS4 developed mainly at Stanford Linear Accelerator Center. It is a widely used code package to simulate particle transport. The results of this work indicates that the method could be used as-is since the accuracy of this method compares to other methods already in use to measure dose rate. Bearing in mind that this method provides the nuclide specific dose it is useful, in radiation protection, since knowing what the relations between different nuclides are and how they change is very important when estimating the risks

  3. 75 FR 59279 - Quarterly IRS Interest Rates Used In Calculating Interest On Overdue Accounts and Refunds On...

    Science.gov (United States)

    2010-09-27

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... notice advises the public of the quarterly Internal Revenue Service interest rates used to calculate... quarter beginning October 1, 2010, the interest rates for overpayments will be 3 percent for corporations...

  4. 45 CFR 261.36 - Do welfare reform waivers affect the calculation of a State's participation rates?

    Science.gov (United States)

    2010-10-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES ENSURING THAT RECIPIENTS WORK What Are the Work Activities and How Do They Count? § 261.36 Do welfare reform waivers affect the calculation of a State's participation rates... 45 Public Welfare 2 2010-10-01 2010-10-01 false Do welfare reform waivers affect the calculation...

  5. Comparison between calculation methods of dose rates in gynecologic brachytherapy

    International Nuclear Information System (INIS)

    Vianello, E.A.; Biaggio, M.F.; D R, M.F.; Almeida, C.E. de

    1998-01-01

    In treatments with radiations for gynecologic tumors is necessary to evaluate the quality of the results obtained by different calculation methods for the dose rates on the points of clinical interest (A, rectal, vesicle). The present work compares the results obtained by two methods. The Manual Calibration Method (MCM) tri dimensional (Vianello E., et.al. 1998), using orthogonal radiographs for each patient in treatment, and the Theraplan/T P-11 planning system (Thratonics International Limited 1990) this last one verified experimentally (Vianello et.al. 1996). The results show that MCM can be used in the physical-clinical practice with a percentile difference comparable at the computerized programs. (Author)

  6. Total dose and dose rate radiation characterization of EPI-CMOS radiation hardened memory and microprocessor devices

    International Nuclear Information System (INIS)

    Gingerich, B.L.; Hermsen, J.M.; Lee, J.C.; Schroeder, J.E.

    1984-01-01

    The process, circuit discription, and total dose radiation characteristics are presented for two second generation hardened 4K EPI-CMOS RAMs and a first generation 80C85 microprocessor. Total dose radiation performance is presented to 10M rad-Si and effects of biasing and operating conditions are discussed. The dose rate sensitivity of the 4K RAMs is also presented along with single event upset (SEU) test data

  7. The reaction rate for dissociative adsorption of N-2 on stepped Ru(0001): Six-dimensional quantum calculations

    DEFF Research Database (Denmark)

    van Harrevelt, Rob; Honkala, Johanna Karoliina; Nørskov, Jens Kehlet

    2005-01-01

    Quantum-mechanical calculations of the reaction rate for dissociative adsorption of N-2 on stepped Ru(0001) are presented. Converged six-dimensional quantum calculations for this heavy-atom reaction have been performed using the multiconfiguration time-dependent Hartree method. A potential...

  8. 78 FR 37839 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2013-06-24

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning July 1, 2013, the interest rates for overpayments will be 2 percent for corporations and 3 percent...

  9. 77 FR 18256 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2012-03-27

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning April 1, 2012, the interest rates for overpayments will be 2 percent for corporations and 3...

  10. 76 FR 41283 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2011-07-13

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning July 1, 2011, the interest rates for overpayments will be 3 percent for corporations and 4 percent...

  11. 78 FR 63238 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2013-10-23

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning October 1, 2013, the interest rates for overpayments will be 2 percent for corporations and 3...

  12. 75 FR 37823 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2010-06-30

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning July 1, 2010, the interest rates for overpayments will be 3 percent for corporations and 4 percent...

  13. 77 FR 59411 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2012-09-27

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning October 1, 2012, the interest rates for overpayments will be 2 percent for corporations and 3...

  14. 77 FR 2308 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2012-01-17

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning January 1, 2012, the interest rates for overpayments will be 2 percent for corporations and 3...

  15. 78 FR 20349 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2013-04-04

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning April 1, 2013, the interest rates for overpayments will be 2 percent for corporations and 3...

  16. 75 FR 419 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2010-01-05

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning January 1, 2010, the interest rates for overpayments will be 3 percent for corporations and 4...

  17. 77 FR 38076 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2012-06-26

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning July 1, 2012, the interest rates for overpayments will be 2 percent for corporations and 3 percent...

  18. 76 FR 20697 - Quarterly IRS Interest Rates Used in Calculating Interest on Overdue Accounts and Refunds on...

    Science.gov (United States)

    2011-04-13

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Quarterly IRS Interest Rates... the public of the quarterly Internal Revenue Service interest rates used to calculate interest on... beginning April 1, 2011, the interest rates for overpayments will be 3 percent for corporations and 4...

  19. Neutron dose rate in the upper part of a PWR containment. Comparison between measurements and TRIPOLI-2 calculations

    International Nuclear Information System (INIS)

    Vergnaud, T.; Bourdet, L.; Gonnord, J.; Nimal, J.C.; Champion, G.

    1984-01-01

    Conception of a reactor building requires large openings in the primary concrete shield for a postulated loss-of-coolant accident. Through these openings neutrons escape and produce dose rates in several parts of the reactor building. Some calculations using ANISN, DOT and essentially TRIPOLI-2 codes allow to compute the neutron dose rates at several places such as reactor containment operating floor and containment annulus. Some complementary shields are provided and the instrumentations are placed in area where the dose rate is lower. Comparisons are presented between measurements and calculations

  20. Calculation of the external dose rate in the spent fuel pool for the case to use compact racks

    International Nuclear Information System (INIS)

    Passos, E.M. dos; Alves, A.S.M.

    1988-01-01

    The possible introduction of compact racks in the spent fuel pool of the Angra 1 Nuclear Power Plant largely inreases its storage capacity, but originates an increase of the gamma radiation sources. The precise evaluation of the effects of the adoption of this option on the external gamma dose rates and also on the thickness of the concrete shielding requires the utilization of sofisticated computer codes (QAD, ANISN), which allow the calculation of the gamma dose rates through thick shielding walls. This paper describes the utilized methodology for the calculation of the modified pool shieldings, showing the obtained results for the Angra 1 NPP case. The gamma dose rate was calculated with the point Kernel model, first analytically, and later through utilization of the tridimensional multigroup QAD computer code. (author) [pt

  1. Quantum chemical and conventional TST calculations of rate constants for the OH + alkane reaction

    International Nuclear Information System (INIS)

    Bravo-Perez, Graciela; Alvarez-Idaboy, J. Raul; Jimenez, Annia Galano; Cruz-Torres, Armando

    2005-01-01

    Reactions of OH with methane, ethane, propane, i-butane, and n-butane have been modeled using ab initio (MP2) and hybrid DFT (BHandHLYP) methods, and the 6-311G(d,p) basis set. Furthermore, single-point calculations at the CCSD(T) level were carried out at the optimized geometries. The rate constants have been calculated using the conventional transition-state theory (CTST). Arrhenius equations are proposed in the temperature range of 250-650 K. Hindered Internal Rotation partition functions calculations were explicitly carried out and included in the total partition functions. These corrections showed to be relevant in the determination of the pre-exponential parameters, although not so important as in the NO 3 + alkane reactions [G. Bravo-Perez, J.R. Alvarez-Idaboy, A. Cruz-Torres, M.E. Ruiz, J. Phys. Chem. A 106 (2002) 4645]. The explicit participation of the tunnel effect has been taken into account. The calculated rate coefficients provide a very good agreement with the experimental data. The best agreement for the overall alkane + OH reactions seemed to occur when the BHandHLYP geometries and partition functions are used. For propane and i-butane, in addition to the respective secondary and tertiary H-abstraction channels, the primary one has been considered. These pathways are confirmed to be significant in spite of the large differences in activation energies between primary and secondary or primary and tertiary channels, respectively of propane and i-butane reactions and should not be disregarded

  2. Extended calculations of energies, transition rates, and lifetimes for F-like Kr XXVIII

    Science.gov (United States)

    Zhang, C. Y.; Si, R.; Yao, K.; Gu, M. F.; Wang, K.; Chen, C. Y.

    2018-02-01

    The excitation energies, lifetimes, wavelengths and E1, E2, M1 and M2 transition rates for the lowest 389 levels of the 2l7, 2l63l‧, 2l64l‧, and 2l65l‧ configurations from second-order many-body perturbation theory (MBPT) calculations, and the results for the lowest 200 states of the 2l7, 2l63l‧, and 2l64l‧ configurations from multi-configuration Dirac-Hartree-Fock (MCDHF) calculations in F-like Kr XXVIII are presented in this work. The relative differences between our two sets of level energies are mostly within 0.005% for the lowest 200 levels. Comparisons are made with experimental and other available theoretical results to assess the reliability and accuracy of the present calculations. We believe them to be the most complete and accurate results for Kr XXVIII at present.

  3. Verification of the LWRARC code for light-water-reactor afterheat rate calculations

    International Nuclear Information System (INIS)

    Murphy, B.D.

    1998-02-01

    This report describes verification studies carried out on the LWRARC (Light-Water-Reactor Afterheat Rate Calculations) computer code. The LWRARC code is proposed for automating the implementation of procedures specified in Draft Revision 1 of the U.S. Nuclear Regulatory Commission (NRC) Regulatory Guide 3.54, open-quotes Spent-Fuel Heat Generation in an Independent Spent-Fuel Storage Installation,close quotes which gives guidelines on the calculation of decay heat for spent nuclear fuel. Draft Regulatory Guide 3.54 allows one to estimate decay-heat values by means of a table lookup procedure with interpolation performed between table-entry values. The tabulated values of the relevant parameters span ranges that are appropriate for spent fuel from a boiling-water reactor (BWR) or a pressurized-water reactor (PWR), as the case may be, and decay-heat rates are obtained for spent fuel whose properties are within those parameter limits. In some instances, where these limits are either exceeded or where they approach critical regions, adjustments are invoked following table lookup. The LWRARC computer code is intended to replicate the manual process just described. In the code, the table lookup is done by entering a database and carrying out interpolations. The code then determines if adjustments apply, and, if this is the case, adjustment factors are calculated separately. The manual procedures in the Draft Regulatory Guide have been validated (i.e., they produce results that are good estimates of reality). The work reported in this document verifies that the LWRARC code replicates the manual procedures of the Draft Regulatory Guide, and that the code, taken together with the Draft Regulatory Guide, can support both verification and validation processes

  4. Preliminary Calculations of Shutdown Dose Rate for the CTS Diagnostics System

    DEFF Research Database (Denmark)

    Klinkby, Esben Bryndt; Nonbøl, Erik; Lauritzen, Bent

    2015-01-01

    DTU and IST 2 are partners in the design of a collective Thomson Scattering (CTS) diagnostics for ITER through a contract with F4E. The CTS diagnostic utilizes probing radiation of ~60 GHz emitted into the plasma and, using a mirror, collects the scattered radiation by an array of receivers. Having...... on supplying input which affect the system design. Examples include: - Heatloads on plasma facing mirrors and preliminary stress and thermal analysis - Port plug cooling requirements and it's dependence on system design (in particular blanket cut-out) - Shutdown dose-rate calculations (relative analysis...

  5. Variationally Optimized Free-Energy Flooding for Rate Calculation

    Science.gov (United States)

    McCarty, James; Valsson, Omar; Tiwary, Pratyush; Parrinello, Michele

    2015-08-01

    We propose a new method to obtain kinetic properties of infrequent events from molecular dynamics simulation. The procedure employs a recently introduced variational approach [Valsson and Parrinello, Phys. Rev. Lett. 113, 090601 (2014)] to construct a bias potential as a function of several collective variables that is designed to flood the associated free energy surface up to a predefined level. The resulting bias potential effectively accelerates transitions between metastable free energy minima while ensuring bias-free transition states, thus allowing accurate kinetic rates to be obtained. We test the method on a few illustrative systems for which we obtain an order of magnitude improvement in efficiency relative to previous approaches and several orders of magnitude relative to unbiased molecular dynamics. We expect an even larger improvement in more complex systems. This and the ability of the variational approach to deal efficiently with a large number of collective variables will greatly enhance the scope of these calculations. This work is a vindication of the potential that the variational principle has if applied in innovative ways.

  6. Computing in the presence of soft bit errors. [caused by single event upset on spacecraft

    Science.gov (United States)

    Rasmussen, R. D.

    1984-01-01

    It is shown that single-event-upsets (SEUs) due to cosmic rays are a significant source of single bit error in spacecraft computers. The physical mechanism of SEU, electron hole generation by means of Linear Energy Transfer (LET), it discussed with reference made to the results of a study of the environmental effects on computer systems of the Galileo spacecraft. Techniques for making software more tolerant of cosmic ray effects are considered, including: reducing the number of registers used by the software; continuity testing of variables; redundant execution of major procedures for error detection; and encoding state variables to detect single-bit changes. Attention is also given to design modifications which may reduce the cosmic ray exposure of on-board hardware. These modifications include: shielding components operating in LEO; removing low-power Schottky parts; and the use of CMOS diodes. The SEU parameters of different electronic components are listed in a table.

  7. Spent Fuel Pool Dose Rate Calculations Using Point Kernel and Hybrid Deterministic-Stochastic Shielding Methods

    International Nuclear Information System (INIS)

    Matijevic, M.; Grgic, D.; Jecmenica, R.

    2016-01-01

    This paper presents comparison of the Krsko Power Plant simplified Spent Fuel Pool (SFP) dose rates using different computational shielding methodologies. The analysis was performed to estimate limiting gamma dose rates on wall mounted level instrumentation in case of significant loss of cooling water. The SFP was represented with simple homogenized cylinders (point kernel and Monte Carlo (MC)) or cuboids (MC) using uranium, iron, water, and dry-air as bulk region materials. The pool is divided on the old and new section where the old one has three additional subsections representing fuel assemblies (FAs) with different burnup/cooling time (60 days, 1 year and 5 years). The new section represents the FAs with the cooling time of 10 years. The time dependent fuel assembly isotopic composition was calculated using ORIGEN2 code applied to the depletion of one of the fuel assemblies present in the pool (AC-29). The source used in Microshield calculation is based on imported isotopic activities. The time dependent photon spectra with total source intensity from Microshield multigroup point kernel calculations was then prepared for two hybrid deterministic-stochastic sequences. One is based on SCALE/MAVRIC (Monaco and Denovo) methodology and another uses Monte Carlo code MCNP6.1.1b and ADVANTG3.0.1. code. Even though this model is a fairly simple one, the layers of shielding materials are thick enough to pose a significant shielding problem for MC method without the use of effective variance reduction (VR) technique. For that purpose the ADVANTG code was used to generate VR parameters (SB cards in SDEF and WWINP file) for MCNP fixed-source calculation using continuous energy transport. ADVATNG employs a deterministic forward-adjoint transport solver Denovo which implements CADIS/FW-CADIS methodology. Denovo implements a structured, Cartesian-grid SN solver based on the Koch-Baker-Alcouffe parallel transport sweep algorithm across x-y domain blocks. This was first

  8. Decay heat rates calculated using ORIGEN-S and CINDER10 with common data libraries

    International Nuclear Information System (INIS)

    Brady, M.C.; Hermann, O.W.; Beard, C.A.; Bohnhoff, W.J.; England, T.R.

    1991-01-01

    A set of two benchmark problems were proposed as part of an international comparison of decay heat codes. Problem specifications included explicit fission-yield, decay and capture data libraries to be used in the calculations. This paper describes the results obtained using these common data to perform the benchmark calculations with two popular depletion codes, ORIGEN-S and CINDER10. Short descriptions of the methods used by each of these codes are also presented. Results from other contributors to the international comparison are discussed briefly. This comparison of decay heat codes using common data libraries demonstrates that discrepant results in calculated decay heat rates are the result of differences in the nuclear data input to the codes and not the method of solution. 15 refs., 2 figs., 8 tabs

  9. Age-related increase in the rate of spontaneou and γ-ray-induced hprt mutations in mouse spleen lymphocytes

    International Nuclear Information System (INIS)

    Gazlev, A.I.; Podlutskii, A.Ya.; Bradbury, R.

    1994-01-01

    Endogenous and exogenous factors continually afflict DNA of cells of organisms. A certain amount of the damage is accumulated causing mutations, increasing the risk of malignacies, impairing cell functions, and upsetting the body's homeostasis. The research reported here studies the rates of spontaneous hprt nmutationsand those induced you ggammairradiation in the splenocytes of mice at various ages. The rate of spontaneous and induced hprt gene mutations increases with aging. In gamma irradiated mice the rate of radiation-induced mutations depended on the absorbed dose and age, with the rate 2.3-3.0 fold higher in 104-110 week old mice than in younger pups. 15 refs., 1 tab

  10. Monte Carlo calculation of correction factors for radionuclide neutron source emission rate measurement by manganese bath method

    International Nuclear Information System (INIS)

    Li Chunjuan; Liu Yi'na; Zhang Weihua; Wang Zhiqiang

    2014-01-01

    The manganese bath method for measuring the neutron emission rate of radionuclide sources requires corrections to be made for emitted neutrons which are not captured by manganese nuclei. The Monte Carlo particle transport code MCNP was used to simulate the manganese bath system of the standards for the measurement of neutron source intensity. The correction factors were calculated and the reliability of the model was demonstrated through the key comparison for the radionuclide neutron source emission rate measurements organized by BIPM. The uncertainties in the calculated values were evaluated by considering the sensitivities to the solution density, the density of the radioactive material, the positioning of the source, the radius of the bath, and the interaction cross-sections. A new method for the evaluation of the uncertainties in Monte Carlo calculation was given. (authors)

  11. Insulator photocurrents: Application to dose rate hardening of CMOS/SOI integrated circuits

    International Nuclear Information System (INIS)

    Dupont-Nivet, E.; Coiec, Y.M.; Flament, O.; Tinel, F.

    1998-01-01

    Irradiation of insulators with a pulse of high energy x-rays can induce photocurrents in the interconnections of integrated circuits. The authors present, here, a new method to measure and analyze this effect together with a simple model. They also demonstrate that these insulator photocurrents have to be taken into account to obtain high levels of dose-rate hardness with CMOS on SOI integrated circuits, especially flip-flops or memory blocks of ASICs. They show that it explains some of the upsets observed in a SRAM embedded in an ASIC

  12. Calculations of the Auger deexcitation rate of dtμ within the muonic quasimolecule (dtμ)dee

    Science.gov (United States)

    Armour, E. A. G.; Lewis, D. M.; Hara, S.

    1992-12-01

    A key process in muon-catalyzed fusion is the deexcitation of dtμ within the resonant muonic quasimolecule (dtμ)dee, by emission of an Auger electron. The dtμ in the quasimolecule is initially in a weakly bound excited state with J=1 and v=1. Calculations are carried out of the rate of the dominant transition to the state with J=0 and v=1. Use is made of the dipole matrix element obtained for this transition by Scrinzi and Szalewicz [Phys. Rev. A 39, 2855 (1989)]. Full account is taken of the molecular nature of the quasimolecule. The continuum electronic wave functions for the Auger electron for all four contributing symmetries, i.e., Σ+g, Σ+u, Πu, and Πg, are first obtained by a two-center Coulomb calculation and a static-exchange calculation, extended to include dipole polarization. Comparison is then made with the results of a calculation in which the Σ+μ and Πu wave functions are obtained as in a previous paper by Armour and Lewis [J. Phys. B 23, L25 (1990)] and the Σ+g and Πg wave functions are obtained by the Kohn method. There are significant differences between the contributions from the individual symmetries, but the overall values for the deexcitation rate are all of the same order of magnitude as the results of earlier calculations.

  13. Variational RRKM calculation of thermal rate constant for C–H bond fission reaction of nitro methane

    Directory of Open Access Journals (Sweden)

    Afshin Taghva Manesh

    2017-02-01

    Full Text Available The present work provides quantitative results for the rate constants of unimolecular C–H bond fission reactions in the nitro methane at elevated temperatures up to 2000 K. In fact, there are three different hydrogen atoms in the nitro methane. The potential energy surface for each C–H bond fission reaction of nitro methane was investigated by ab initio calculations. The geometry and vibrational frequencies of the species involved in this process were optimized at the MP2 level of theory, using the cc-pvdz basis set. Since C–H bond fission channel is a barrierless reaction, we have used variational RRKM theory to predict rate coefficients. By means of calculated rate coefficients at different temperatures, the Arrhenius expression of the channel over the temperature range of 100–2000 K is k(T = 5.9E19∗exp(−56274.6/T.

  14. ESCLOUD: A computer program to calculate the air concentration, deposition rate and external dose rate from a continuous discharge of radioactive material to atmosphere

    International Nuclear Information System (INIS)

    Jones, J.A.

    1980-03-01

    Radioactive material may be discharged to atmosphere in small quantities during the normal operation of a nuclear installation as part of a considered waste management practice. Estimates of the individual and collective dose equivalent rates resulting from such a discharge are required in a number of contexts: for example, in assessing compliance with dose limits, in estimating the radiological impact of the discharge and as an input into optimisation studies. The suite of programs which has been developed to undertake such calculations is made up of a number of independent modules one of which, ESCLOUD, is described in this report. The ESCLOUD program evaluates, as a function of distance and direction from the release point, the air concentration, deposition rate and external β and γ doses from airborne and deposited activity. The air concentration and deposition rate can be used as input to other modules for calculating inhalation and ingestion doses. (author)

  15. User's guide to SERICPAC: A computer program for calculating electric-utility avoided costs rates

    Energy Technology Data Exchange (ETDEWEB)

    Wirtshafter, R.; Abrash, M.; Koved, M.; Feldman, S.

    1982-05-01

    SERICPAC is a computer program developed to calculate average avoided cost rates for decentralized power producers and cogenerators that sell electricity to electric utilities. SERICPAC works in tandem with SERICOST, a program to calculate avoided costs, and determines the appropriate rates for buying and selling of electricity from electric utilities to qualifying facilities (QF) as stipulated under Section 210 of PURA. SERICPAC contains simulation models for eight technologies including wind, hydro, biogas, and cogeneration. The simulations are converted in a diversified utility production which can be either gross production or net production, which accounts for an internal electricity usage by the QF. The program allows for adjustments to the production to be made for scheduled and forced outages. The final output of the model is a technology-specific average annual rate. The report contains a description of the technologies and the simulations as well as complete user's guide to SERICPAC.

  16. FPGA-based Bit-Error-Rate Tester for SEU-hardened Optical Links

    CERN Document Server

    Detraz, S; Moreira, P; Papadopoulos, S; Papakonstantinou, I; Seif El Nasr, S; Sigaud, C; Soos, C; Stejskal, P; Troska, J; Versmissen, H

    2009-01-01

    The next generation of optical links for future High-Energy Physics experiments will require components qualified for use in radiation-hard environments. To cope with radiation induced single-event upsets, the physical layer protocol will include Forward Error Correction (FEC). Bit-Error-Rate (BER) testing is a widely used method to characterize digital transmission systems. In order to measure the BER with and without the proposed FEC, simultaneously on several devices, a multi-channel BER tester has been developed. This paper describes the architecture of the tester, its implementation in a Xilinx Virtex-5 FPGA device and discusses the experimental results.

  17. Sample size calculation while controlling false discovery rate for differential expression analysis with RNA-sequencing experiments.

    Science.gov (United States)

    Bi, Ran; Liu, Peng

    2016-03-31

    RNA-Sequencing (RNA-seq) experiments have been popularly applied to transcriptome studies in recent years. Such experiments are still relatively costly. As a result, RNA-seq experiments often employ a small number of replicates. Power analysis and sample size calculation are challenging in the context of differential expression analysis with RNA-seq data. One challenge is that there are no closed-form formulae to calculate power for the popularly applied tests for differential expression analysis. In addition, false discovery rate (FDR), instead of family-wise type I error rate, is controlled for the multiple testing error in RNA-seq data analysis. So far, there are very few proposals on sample size calculation for RNA-seq experiments. In this paper, we propose a procedure for sample size calculation while controlling FDR for RNA-seq experimental design. Our procedure is based on the weighted linear model analysis facilitated by the voom method which has been shown to have competitive performance in terms of power and FDR control for RNA-seq differential expression analysis. We derive a method that approximates the average power across the differentially expressed genes, and then calculate the sample size to achieve a desired average power while controlling FDR. Simulation results demonstrate that the actual power of several popularly applied tests for differential expression is achieved and is close to the desired power for RNA-seq data with sample size calculated based on our method. Our proposed method provides an efficient algorithm to calculate sample size while controlling FDR for RNA-seq experimental design. We also provide an R package ssizeRNA that implements our proposed method and can be downloaded from the Comprehensive R Archive Network ( http://cran.r-project.org ).

  18. Approximate techniques for calculating gamma ray dose rates in nuclear power plants

    International Nuclear Information System (INIS)

    Lahti, G.P.

    1986-01-01

    Although today's computers have made three-dimensional discrete ordinates transport codes a virtual reality, there is still a need for approximate techniques for estimating radiation environments. This paper discusses techniques for calculating gamma ray dose rates in nuclear power plants where Compton scattering is the dominant attenuation mechanism. The buildup factor method is reviewed; its use and misuse are discussed. Several useful rules-of-thumb are developed. The paper emphasizes the need for understanding the fundamental physics and draws heavily on the old, classic references

  19. Cross-section and rate coefficient calculation for electron impact excitation, ionisation and dissociation of H2 and OH molecules

    International Nuclear Information System (INIS)

    Riahi, R.; Ben Lakhdar, Z.; Teulet, Ph.; Gleizes, A.

    2006-01-01

    The weighted total cross-sections (WTCS) theory is used to calculate electron impact excitation, ionization and dissociation cross-sections and rate coefficients of OH, H 2 , OH + , H 2 + , OH - and H 2 - diatomic molecules in the temperature range 1500-15000 K. Calculations are performed for H 2 (X, B, C), OH(X, A, B), H 2 + (X), OH + (X, a, A, b, c), H 2 - (X) and OH - (X) electronic states for which Dunham coefficients are available. Rate coefficients are calculated from WTCS assuming Maxwellian energy distribution functions for electrons and heavy particles. One and 2 temperatures (θ e and θ g respectively for electron and heavy particles kinetic temperatures) results are presented and fitting parameters (a, b and c) are given for each reaction rate coefficient: k(θ) a(θ b )exp(-c/θ). (authors)

  20. Calculating Production Rate of each Branch of a Multilateral Well Using Multi-Segment Well Model: Field Example

    Directory of Open Access Journals (Sweden)

    Mohammed S. Al-Jawad

    2017-11-01

    Full Text Available Multilateral wells require a sophisticated type of well model to be applied in reservoir simulators to represent them. The model must be able to determine the flow rate of each fluid and the pressure throughout the well. The production rate calculations are very important because they give an indication about some main issues associated with multi-lateral wells such as one branch may produce water or gas before others, no production rate from one branch, and selecting the best location of a new branch for development process easily. This paper states the way to calculate production rate of each branch of a multilateral well-using multi-segment well model. The pressure behaviour of each branch is simulated dependent on knowing its production rate. This model has divided a multi-lateral well into an arbitrary number of segments depending on the required degree of accuracy and run time of the simulator. The model implemented on a field example (multi-lateral well HF-65ML in Halfaya Oil Field/Mishrif formation. The production rate and pressure behaviour of each branch are simulated during the producing interval of the multilateral well. The conclusion is that production rate of the main branch is slightly larger than a lateral branch.

  1. The effects of cosmic radiation on implantable medical devices

    International Nuclear Information System (INIS)

    Bradley, P.

    1996-01-01

    Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 Gγ) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main pervasive ionising radiation threat to the reliability of implantable devices. A theoretical model which predicts the susceptibility of a RAM cell to secondary neutron cosmic radiation induced SEU is presented. The model correlates well within the statistical uncertainty associated with both the theoretical and field estimate. The predicted Soft Error Rate (SER) is 4.8 x l0 -12 upsets/(bit hr) compared to an observed upset rate of 8.5 x 10 -12 upsets/(bit hr) from 20 upsets collected over a total of 284672 device days. The predicted upset rate may increase by up to 20% when consideration is given to patients flying in aircraft The upset rate is also consistent with the expected geographical variations of the secondary cosmic ray neutron flux, although insufficient upsets precluded a statistically significant test. This is the first clinical data set obtained indicating the effects of cosmic radiation on implantable devices. Importantly, it may be used to predict the susceptibility of future to the implantable device designs to the effects of cosmic radiation

  2. Calculating in situ degradation rates of hydrocarbon compounds in deep waters of the Gulf of Mexico.

    Science.gov (United States)

    Thessen, Anne E; North, Elizabeth W

    2017-09-15

    Biodegradation is an important process for hydrocarbon weathering that influences its fate and transport, yet little is known about in situ biodegradation rates of specific hydrocarbon compounds in the deep ocean. Using data collected in the Gulf of Mexico below 700m during and after the Deepwater Horizon oil spill, we calculated first-order degradation rate constants for 49 hydrocarbons and inferred degradation rate constants for an additional 5 data-deficient hydrocarbons. Resulting calculated (not inferred) half-lives of the hydrocarbons ranged from 0.4 to 36.5days. The fastest degrading hydrocarbons were toluene (k=-1.716), methylcyclohexane (k=-1.538), benzene (k=-1.333), and C1-naphthalene (k=-1.305). The slowest degrading hydrocarbons were the large straight-chain alkanes, C-26 through C-33 (k=-0.0494 through k=-0.007). Ratios of C-18 to phytane supported the hypothesis that the primary means of degradation in the subsurface was microbial biodegradation. These degradation rate constants can be used to improve models describing the fate and transport of hydrocarbons in the event of an accidental deep ocean oil spill. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Chrysler Upset Protrusion Joining Techniques for Joining Dissimilar Metals

    Energy Technology Data Exchange (ETDEWEB)

    Logan, Stephen [FCA US LLC, Auburn Hills, MI (United States)

    2017-09-28

    The project goal was to develop and demonstrate a robust, cost effective, and versatile joining technique, known as Upset Protrusion Joining (UPJ), for joining challenging dissimilar metal com-binations, especially those where one of the metals is a die cast magnesium (Mg) component. Since two of the key obstacles preventing more widespread use of light metals (especially in high volume automotive applications) are 1) a lack of robust joining techniques and 2) susceptibility to galvanic corrosion, and since the majority of the joint combinations evaluated in this project include die cast Mg (the lightest structural metal) as one of the two materials being joined, and since die casting is the most common and cost effective process for producing Mg components, then successful project completion provides a key enabler to high volume application of lightweight materials, thus potentially leading to reduced costs, and encouraging implementation of lightweight multi-material vehicles for significant reductions in energy consumption and reduced greenhouse gas emissions. Eco-nomic benefits to end-use consumers are achieved primarily via the reduction in fuel consumption. Unlike currently available commercial processes, the UPJ process relies on a very robust mechanical joint rather than intermetallic bonding, so the more cathodic material can be coated prior to joining, thus creating a robust isolation against galvanic attack on the more anodic material. Additionally, since the UPJ protrusion is going through a hole that can be pre-drilled or pre-punched prior to coating, the UPJ process is less likely to damage the coating when the joint is being made. Further-more, since there is no additional cathodic material (such as a steel fastener) used to create the joint, there is no joining induced galvanic activity beyond that of the two parent materials. In accordance with its originally proposed plan, this project has successfully developed process variants of UPJ to enable

  4. Hawaii's epidemic dental decay rate in children.

    Science.gov (United States)

    Sueda, Stacie T

    2008-01-01

    The purpose of this study was to determine if other factors besides community water fluoridation influences the dental decay rate in children. Identical questionnaires were filled out by two groups of parents, both with a sample size of 100, whose healthy children (ages 5-12) were patients of a pediatric dentist practicing in a non-fluoridated water community. Group A had children with zero Decay or Filled Teeth (DFT). Group B had children with at least five DFT. Children were found to have a significantly lower dental decay rate (P disciplining them; 7) the child was are not "strong-willed" or "hard-headed;" 8) someone does not appease (or "give in" to) them when they get upset; 9) they do not live in a single parent household; and 10) at least one parent achieves a higher academic educational level. This study suggests that water fluoridation is not the only way to prevent dental decay.

  5. Reconciliation of Measured and TRANSP-calculated Neutron Emission Rates in the National Spherical Torus Experiment: Circa 2002-2005

    International Nuclear Information System (INIS)

    Medley, S.S.; Darrow, D.S.; Roquemore, A.L.

    2005-01-01

    A change in the response of the neutron detectors on the National Spherical Torus Experiment occurred between the 2002-2003 and 2004 experimental run periods. An analysis of this behavior by investigating the neutron diagnostic operating conditions and comparing measured and TRANSP-calculated neutron rates is presented. Also a revised procedure for cross calibration of the neutron scintillator detectors with the fission chamber detectors was implemented that delivers good agreement amongst the measured neutron rates for all neutron detectors and all run periods. For L-mode discharges, the measured and TRANSP-calculated neutron rates now match closely for all run years. For H-mode discharges over the entire 2002-2004 period, the 2FG scintillator and fission chamber measurements match each other but imply a neutron deficit of 11.5% relative to the TRANSP-calculated neutron. The results of this report impose a modification on all of the previously used calibration factors for the entire neutron detector suite over the 2002-2004 period. A tabular summary of the new calibration factors is provided including certified calibration factors for the 2005 run

  6. Magma addition rates in continental arcs: New methods of calculation and global implications

    Science.gov (United States)

    Ratschbacher, B. C.; Paterson, S. R.

    2017-12-01

    The transport of mass, heat and geochemical constituents (elements and volatiles) from the mantle to the atmosphere occurs via magma addition to the lithosphere. Calculation of magma addition rates (MARs) in continental arcs based on exposed proportions of igneous arc rocks is complex and rarely consistently determined. Multiple factors influence MAR calculations such as crust versus mantle contributions to magmas, a change in MARs across the arc and with depths throughout the arc crustal column, `arc tempos' with periods of high and low magmatic activity, the loss of previous emplaced arc rocks by subsequent magmatism and return to the mantle, arc migration, variations in the intrusive versus extrusive additions and evolving arc widths and thicknesses during tectonism. All of these factors need to be considered when calculating MARs.This study makes a new attempt to calculate MARs in continental arcs by studying three arc sections: the Famatinian arc, Argentina, the Sierra Nevada batholith, California and the Coast Mountain batholith, Washington and British Columbia. Arcs are divided into fore-arc, main arc and back arc sections and `boxes' with a defined width, length and thickness spanning upper middle and lower crustal levels are assigned to each section. Representative exposed crustal slices for each depth are then used to calculate MARs based on outcrop proportions for each box. Geochemical data is used to infer crustal recycling percentages and total thickness of the arc. Preliminary results show a correlation between MARs, crustal thicknesses and magmatic flare-up durations. For instance, the Famatinian arc shows a strong decrease in MARs between the main arc section (9.4 km3/Ma/arc-km) and the fore-arc (0.61 km3/Ma/arc-km) and back-arc (1.52 km3/Ma/arc-km) regions and an increase in the amount of magmatism with depth.Global MARs over geologic timescales have the potential to investigate mantle melt generation rates and the volatile outgassing contribution

  7. An Online Calculator to Estimate the Impact of Changes in Breastfeeding Rates on Population Health and Costs.

    Science.gov (United States)

    Stuebe, Alison M; Jegier, Briana J; Schwarz, Eleanor Bimla; Green, Brittany D; Reinhold, Arnold G; Colaizy, Tarah T; Bogen, Debra L; Schaefer, Andrew J; Jegier, Jamus T; Green, Noah S; Bartick, Melissa C

    2017-12-01

    We sought to determine the impact of changes in breastfeeding rates on population health. We used a Monte Carlo simulation model to estimate the population-level changes in disease burden associated with marginal changes in rates of any breastfeeding at each month from birth to 12 months of life, and in rates of exclusive breastfeeding from birth to 6 months of life. We used these marginal estimates to construct an interactive online calculator (available at www.usbreastfeeding.org/saving-calc ). The Institutional Review Board of the Cambridge Health Alliance exempted the study. Using our interactive online calculator, we found that a 5% point increase in breastfeeding rates was associated with statistically significant differences in child infectious morbidity for the U.S. population, including otitis media (101,952 cases, 95% confidence interval [CI] 77,929-131,894 cases) and gastrointestinal infection (236,073 cases, 95% CI 190,643-290,278 cases). Associated medical cost differences were $31,784,763 (95% CI $24,295,235-$41,119,548) for otitis media and $12,588,848 ($10,166,203-$15,479,352) for gastrointestinal infection. The state-level impact of attaining Healthy People 2020 goals varied by population size and current breastfeeding rates. Modest increases in breastfeeding rates substantially impact healthcare costs in the first year of life.

  8. Methods of neutron spectrum calculation from measured reaction rates in saips. Part 1. Review of mathematical methods

    International Nuclear Information System (INIS)

    Bondars, Kh.Ya.; Lapenas, A.A.

    1981-01-01

    We adapted or used on ES EhVM, operating under the control of OS ES, the currently most common algorithms for calculating neutron spectra from measured reaction rates. These programs, together with the neutron cross-section and spectrum libraries, are part of the computerized information system SAIPS. The present article descibes the basic mathematical concepts used in the algorithms of the SAIPS calculation programs

  9. Plutonium-aerosol emission rates and human pulmonary deposition calculations for Nuclear Site 201, Nevada Test Site

    International Nuclear Information System (INIS)

    Shinn, J.H.; Homan, D.N.

    1982-01-01

    This study determined the plutonium-aerosol fluxes from the soil to quantify (1) the extent of potential human exposure by deep-lung retention of alpha-emitting particles; (2) the source term should there be any significant, long-term, transport of plutonium aerosols; and (3) the resuspension factor and rate so that, for the first time at any nuclear site, one may calculate how long it will take for wind erosion to carry away a significant amount of the contaminated soil. High-volume air samplers and cascade impactors were used to characterize the plutonium aerosols. Meteorological flux-profile methods were used to calculate dust and plutonium aerosol emission rates. A floorless wind tunnel (10-m long) was used to examine resuspension under steady-state, high wind speed. The resuspension factor was two orders of magnitude lower than the other comparable sites at NTS and elsewhere, and the average resuspension rate of 5.3 x 10 -8 /d was also very low, so that the half-time for resuspension by wind erosion was about 36,000 y

  10. Implications of imprecision in kinetic rate data for photochemical model calculations

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, R.W.; Thompson, A.M. [National Aeronautics and Space Administration, Greenbelt, MD (United States). Goddard Space Flight Center

    1997-12-31

    Evaluation of uncertainties in photochemical model calculations is of great importance to scientists performing assessment modeling. A major source of uncertainty is the measurement imprecision inherent in photochemical reaction rate data that modelers rely on. A rigorous method of evaluating the impact of data imprecision on computational uncertainty is the study of error propagation using Monte Carlo techniques. There are two problems with the current implementation of the Monte Carlo method. First, there is no satisfactory way of accounting for the variation of imprecision with temperature in 1, 2, or 3D models; second, due to its computational expense, it is impractical in 3D model studies. These difficulties are discussed. (author) 4 refs.

  11. Implications of imprecision in kinetic rate data for photochemical model calculations

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, R W; Thompson, A M [National Aeronautics and Space Administration, Greenbelt, MD (United States). Goddard Space Flight Center

    1998-12-31

    Evaluation of uncertainties in photochemical model calculations is of great importance to scientists performing assessment modeling. A major source of uncertainty is the measurement imprecision inherent in photochemical reaction rate data that modelers rely on. A rigorous method of evaluating the impact of data imprecision on computational uncertainty is the study of error propagation using Monte Carlo techniques. There are two problems with the current implementation of the Monte Carlo method. First, there is no satisfactory way of accounting for the variation of imprecision with temperature in 1, 2, or 3D models; second, due to its computational expense, it is impractical in 3D model studies. These difficulties are discussed. (author) 4 refs.

  12. Calculation of Rates of 4p–4d Transitions in Ar II

    Directory of Open Access Journals (Sweden)

    Alan Hibbert

    2017-02-01

    Full Text Available Recent experimental work by Belmonte et al. (2014 has given rates for some 4p–4d transitions that are significantly at variance with the previous experimental work of Rudko and Tang (1967 recommended in the NIST tabulations. To date, there are no theoretical rates with which to compare. In this work, we provide such theoretical data. We have undertaken a substantial and systematic configuration interaction calculation, with an extrapolation process applied to ab initio mixing coefficients, which gives energy differences in agreement with experiment. The length and velocity forms give values that are within 10%–15% of each other. Our results are in sufficiently close agreement with those of Belmonte et al. that we can confidently recommend that their results are much more accurate than the early results of Rudko and Tang, and should be adopted in place of the latter.

  13. Calculation of the decay rate of the proton

    International Nuclear Information System (INIS)

    Ross, D.A.

    1980-01-01

    The SU(5) model of Georgi and Glashow is used for these calculations, being the simplist such model and since the point of unification of the strong, weak and electromagnetic interactions is very intensitive to the exact details of the model provided it obeys the desert hypothesis. The broad features of the calculation are common to all models with a dessert between the W-mass and unification

  14. Method for calculation of upper limit internal alpha dose rates to aquatic organisms with application of plutonium-239 in plankton

    International Nuclear Information System (INIS)

    Paschoa, A.S.; Baptista, G.B.

    1977-01-01

    A method for the calculation of upper limit internal alpha dose rates to aquatic organisms is presented. The mean alpha energies per disintegration of radionuclides of interest are listed to be used in standard methodologies to calculate dose to aquatic biota. As an application, the upper limits for the alpha dose rates from 239 Pu to the total body of plankton are estimated based on data available in open literature [pt

  15. Calculation of astrophysical S-factor and reaction rate in 12C(p, γ)13N reaction

    Science.gov (United States)

    Moghadasi, A.; Sadeghi, H.; Pourimani, R.

    2018-02-01

    The 12C(p, γ)13N reaction is the first process in the CNO cycle. Also it is a source of low-energy solar neutrinos in various neutrino experiments. Therefore, it is of high interest to gain data of the astrophysical S-factor in low energies. By applying Faddeev's method, we calculated wave functions for the bound state of 13N. Then the cross sections for resonance and non-resonance were calculated through using Breit-Wigner and direct capture cross section formulae, respectively. After that, we calculated the total S-factor and compared it with previous experimental data, revealing a good agreement altogether. Then, we extrapolated the S-factor in zero energy and the result was 1.32 ± 0.19 (keV.b). In the end, we calculated reaction rate and compared it with NACRE data.

  16. 31 CFR 351.13 - What do I need to know about the savings bond rate to understand redemption value calculations in...

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false What do I need to know about the savings bond rate to understand redemption value calculations in this subpart? 351.13 Section 351.13 Money... What do I need to know about the savings bond rate to understand redemption value calculations in this...

  17. Optically stimulated luminescence dating as a tool for calculating sedimentation rates in Chinese loess: comparisons with grain-size records

    DEFF Research Database (Denmark)

    Stevens, Thomas; Lu, HY

    2009-01-01

    Understanding loess sedimentation rates is crucial for constraining past atmospheric dust dynamics, regional climatic change and local depositional environments. However, the derivation of loess sedimentation rates is complicated by the lack of available methods for independent calculation......) the influences on sediment grain-size and accumulation; and (ii) their relationship through time and across the depositional region. This uncertainty has led to the widespread use of assumptions concerning the relationship between sedimentation rate and grain-size in order to derive age models and climate...... reconstructions. To address this uncertainty, detailed independent age models, based on optically stimulated luminescence dating, undertaken at 10 to 40 cm intervals at five sections across the Loess Plateau in China, have been used to calculate sedimentation rates and make comparisons with grain-size changes...

  18. Heart rate calculation from ensemble brain wave using wavelet and Teager-Kaiser energy operator.

    Science.gov (United States)

    Srinivasan, Jayaraman; Adithya, V

    2015-01-01

    Electroencephalogram (EEG) signal artifacts are caused by various factors, such as, Electro-oculogram (EOG), Electromyogram (EMG), Electrocardiogram (ECG), movement artifact and line interference. The relatively high electrical energy cardiac activity causes EEG artifacts. In EEG signal processing the general approach is to remove the ECG signal. In this paper, we introduce an automated method to extract the ECG signal from EEG using wavelet and Teager-Kaiser energy operator for R-peak enhancement and detection. From the detected R-peaks the heart rate (HR) is calculated for clinical diagnosis. To check the efficiency of our method, we compare the HR calculated from ECG signal recorded in synchronous with EEG. The proposed method yields a mean error of 1.4% for the heart rate and 1.7% for mean R-R interval. The result illustrates that, proposed method can be used for ECG extraction from single channel EEG and used in clinical diagnosis like estimation for stress analysis, fatigue, and sleep stages classification studies as a multi-model system. In addition, this method eliminates the dependence of additional synchronous ECG in extraction of ECG from EEG signal process.

  19. Verification of dose rate calculation and selection study on low activation concrete in fusion facilities

    International Nuclear Information System (INIS)

    Oishi, Koji; Minami, Kiyoshi; Ikeda, Yujiro; Kosako, Kazuaki; Nakamura, Tomoo

    1991-01-01

    A concrete assembly was irradiated by D-T neutrons for 10 h, and dose rate measurement one day after shutdown has been carried out in order to provide a guide line for selection studies of low activation concrete. The experimental results were analyzed by the two dimensional calculation code DOT3.5 with its related nuclear data library GICX40 based on ENDF/B-III, however disagreement between experiment and calculation was observed in the deeper detector positions. Calculations were also performed using the nuclear data library based on ENDF/B-IV, and agreement within experimental errors was obtained at all detector positions. Selection studies for low activation concrete were performed using this nuclear data library. As a result, it was found that limestone concrete exhibited excellent properties as a low activation concrete in fusion facilities. (orig.)

  20. Notice of Violation of IEEE Publication PrinciplesJoint Redundant Residue Number Systems and Module Isolation for Mitigating Single Event Multiple Bit Upsets in Datapath

    Science.gov (United States)

    Li, Lei; Hu, Jianhao

    2010-12-01

    Notice of Violation of IEEE Publication Principles"Joint Redundant Residue Number Systems and Module Isolation for Mitigating Single Event Multiple Bit Upsets in Datapath"by Lei Li and Jianhao Hu,in the IEEE Transactions on Nuclear Science, vol.57, no.6, Dec. 2010, pp. 3779-3786After careful and considered review of the content and authorship of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE's Publication Principles.This paper contains substantial duplication of original text from the paper cited below. The original text was copied without attribution (including appropriate references to the original author(s) and/or paper title) and without permission.Due to the nature of this violation, reasonable effort should be made to remove all past references to this paper, and future references should be made to the following articles:"Multiple Error Detection and Correction Based on Redundant Residue Number Systems"by Vik Tor Goh and M.U. Siddiqi,in the IEEE Transactions on Communications, vol.56, no.3, March 2008, pp.325-330"A Coding Theory Approach to Error Control in Redundant Residue Number Systems. I: Theory and Single Error Correction"by H. Krishna, K-Y. Lin, and J-D. Sun, in the IEEE Transactions on Circuits and Systems II: Analog and Digital Signal Processing, vol.39, no.1, Jan 1992, pp.8-17In this paper, we propose a joint scheme which combines redundant residue number systems (RRNS) with module isolation (MI) for mitigating single event multiple bit upsets (SEMBUs) in datapath. The proposed hardening scheme employs redundant residues to improve the fault tolerance for datapath and module spacings to guarantee that SEMBUs caused by charge sharing do not propagate among the operation channels of different moduli. The features of RRNS, such as independence, parallel and error correction, are exploited to establish the radiation hardening architecture for the datapath in radiation environments. In the proposed

  1. Calculating the dim light melatonin onset: the impact of threshold and sampling rate.

    Science.gov (United States)

    Molina, Thomas A; Burgess, Helen J

    2011-10-01

    The dim light melatonin onset (DLMO) is the most reliable circadian phase marker in humans, but the cost of assaying samples is relatively high. Therefore, the authors examined differences between DLMOs calculated from hourly versus half-hourly sampling and differences between DLMOs calculated with two recommended thresholds (a fixed threshold of 3 pg/mL and a variable "3k" threshold equal to the mean plus two standard deviations of the first three low daytime points). The authors calculated these DLMOs from salivary dim light melatonin profiles collected from 122 individuals (64 women) at baseline. DLMOs derived from hourly sampling occurred on average only 6-8 min earlier than the DLMOs derived from half-hourly saliva sampling, and they were highly correlated with each other (r ≥ 0.89, p 30 min from the DLMO derived from half-hourly sampling. The 3 pg/mL threshold produced significantly less variable DLMOs than the 3k threshold. However, the 3k threshold was significantly lower than the 3 pg/mL threshold (p < .001). The DLMOs calculated with the 3k method were significantly earlier (by 22-24 min) than the DLMOs calculated with the 3 pg/mL threshold, regardless of sampling rate. These results suggest that in large research studies and clinical settings, the more affordable and practical option of hourly sampling is adequate for a reasonable estimate of circadian phase. Although the 3 pg/mL fixed threshold is less variable than the 3k threshold, it produces estimates of the DLMO that are further from the initial rise of melatonin.

  2. Dose Rate Experiment at JET for Benchmarking the Calculation Direct One Step Method

    International Nuclear Information System (INIS)

    Angelone, M.; Petrizzi, L.; Pillon, M.; Villari, R.; Popovichev, S.

    2006-01-01

    , experimental background data and dose rate, the latter collected during some operation free days in the early phase of the 2006 JET campaign, are compared with the same quantities calculated using the D1S approach. The impact of key parameters (geometrical model, materials impurities, different sets of cross sections) to the calculated dose rates is discussed as well. (author)

  3. Calculation of rate coefficients of some proton-transfer ion-molecule reactions in weakly ionized gases

    International Nuclear Information System (INIS)

    Stiller, W.

    1985-01-01

    A classical collision theory is used to describe thermal bimolecular rate coefficeints for reaction between positive and negative ions and polar molecules in a carrier gas. Special attention is paid to ion-molecule reaction in which proton transfer occurs. These reactions play an important role in terrestrial plasma devices, in ionosphere, in planetary atmospheres and in interstellar matter. The equilibrium rate coefficients of the reactions are calculated based on a microscopic reactive cross section derived from a long distance polar molecule-ion potential. The results are compared with experimental values of afterglow measurements. (D.Gy.)

  4. Comparison of calculated and measured soil-gas radon concentration and radon exhalation rate

    International Nuclear Information System (INIS)

    Neznal, Martin; Neznal, Matej; Jiranek, Martin

    2000-01-01

    The computer model RADON2D for WINDOWS, which makes it possible to estimate the radon exhalation rate from the ground surface and the distribution of soil-gas radon concentration, was tested using a large set of experimental data coming from four reference areas located in regions with different geological structure. A good agreement between calculated and experimental data was observed. In the majority of cases, a correct description of the real situation was obtained using non-modified experimental input data. (author)

  5. Determination of uncertainties in the calculation of dose rates at transport and storage casks; Unsicherheiten bei der Berechnung von Dosisleistungen an Transport- und Lagerbehaeltern

    Energy Technology Data Exchange (ETDEWEB)

    Schloemer, Luc Laurent Alexander

    2014-12-17

    The compliance with the dose rate limits for transport and storage casks (TLB) for spent nuclear fuel from pressurised water reactors can be proved by calculation. This includes the determination of the radioactive sources and the shielding-capability of the cask. In this thesis the entire computational chain, which extends from the determination of the source terms to the final Monte-Carlo-transport-calculation is analysed and the arising uncertainties are quantified not only by benchmarks but also by variational calculi. The background of these analyses is that the comparison with measured dose rates at different TLBs shows an overestimation by the values calculated. Regarding the studies performed, the overestimation can be mainly explained by the detector characteristics for the measurement of the neutron dose rate and additionally in case of the gamma dose rates by the energy group structure, which the calculation is based on. It turns out that the consideration of the uncertainties occurring along the computational chain can lead to even greater overestimation. Concerning the dose rate calculation at cask loadings with spent uranium fuel assemblies an uncertainty of (({sup +21}{sub -28}) ±2) % (rel.) for the total gamma dose rate and of ({sup +28±23}{sub -55±4}) % (rel.) for the total neutron dose rate are estimated. For mixed-loadings with spent uranium and MOX fuel assemblies an uncertainty of ({sup +24±3}{sub -27±2}) % (rel.) for the total gamma dose rate and of ({sup +28±23}{sub -55±4}) % (rel.) for the total neutron dose rate are quantified. The results show that the computational chain has not to be modified, because the calculations performed lead to conservative dose rate predictions, even if high uncertainties at neutron dose rate measurements arise. Thus at first the uncertainties of the neutron dose rate measurement have to be decreased to enable a reduction of the overestimation of the calculated dose rate afterwards. In the present thesis

  6. Calculation of homogenized Pickering NGS stainless steel adjuster rod neutron cross-sections using conservation of reaction rates

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, R C [Atlantic Nuclear Services Ltd. (Canada); Tran, F [Ontario Hydro, Pickering, ON (Canada). Pickering Generating Station

    1996-12-31

    A homogenization methodology for calculation of reactivity device incremental cross-sections has been developed using reaction rate conservation (RRC). A heterogeneous transport calculation of flux was utilised to produce the homogenized cross-sections for a finite difference two group diffusion code. The RRC cross-sections have been shown to improve significantly the prediction of reactivity worth for stainless steel adjuster rods installed in Pickering NGS reactors. (author). 10 refs., 3 tabs., 6 figs.

  7. Simple experimentally derived algorithm for computer calculated dose rates associated with 137Cs gynecologic insertions

    International Nuclear Information System (INIS)

    Wrede, D.E.; Dawalibi, H.

    1980-01-01

    A simple mathematical algorithm is derived from experimental data for dose rates from 137 Cs sources in a finite tissue equivalent medium corresponding to the female pelvis. An analytical expression for a point source of 137 Cs along with a simple numerical integration routine allows for rapid as well as accurate dose rate calculations at points of interest for gynecologic insertions. When compared with theoretical models assuming an infinite unit density medium, the measured dose rates are found to be systematically lower at distances away from a single source; 5 per cent at 2 cm and 10 per cent at 7 cm along the transverse axis. Allowance in the program for print out of dose rates from individual sources to a given point and the feature of source strength modification allows for optimization in terms of increasing the difference in dose rate between reference treatment points and sensitive structures such as the bladder, rectum and colon. (Auth.)

  8. Forward flux sampling calculation of homogeneous nucleation rates from aqueous NaCl solutions.

    Science.gov (United States)

    Jiang, Hao; Haji-Akbari, Amir; Debenedetti, Pablo G; Panagiotopoulos, Athanassios Z

    2018-01-28

    We used molecular dynamics simulations and the path sampling technique known as forward flux sampling to study homogeneous nucleation of NaCl crystals from supersaturated aqueous solutions at 298 K and 1 bar. Nucleation rates were obtained for a range of salt concentrations for the Joung-Cheatham NaCl force field combined with the Extended Simple Point Charge (SPC/E) water model. The calculated nucleation rates are significantly lower than the available experimental measurements. The estimates for the nucleation rates in this work do not rely on classical nucleation theory, but the pathways observed in the simulations suggest that the nucleation process is better described by classical nucleation theory than an alternative interpretation based on Ostwald's step rule, in contrast to some prior simulations of related models. In addition to the size of NaCl nucleus, we find that the crystallinity of a nascent cluster plays an important role in the nucleation process. Nuclei with high crystallinity were found to have higher growth probability and longer lifetimes, possibly because they are less exposed to hydration water.

  9. Benchmarking of MCNP for calculating dose rates at an interim storage facility for nuclear waste.

    Science.gov (United States)

    Heuel-Fabianek, Burkhard; Hille, Ralf

    2005-01-01

    During the operation of research facilities at Research Centre Jülich, Germany, nuclear waste is stored in drums and other vessels in an interim storage building on-site, which has a concrete shielding at the side walls. Owing to the lack of a well-defined source, measured gamma spectra were unfolded to determine the photon flux on the surface of the containers. The dose rate simulation, including the effects of skyshine, using the Monte Carlo transport code MCNP is compared with the measured dosimetric data at some locations in the vicinity of the interim storage building. The MCNP data for direct radiation confirm the data calculated using a point-kernel method. However, a comparison of the modelled dose rates for direct radiation and skyshine with the measured data demonstrate the need for a more precise definition of the source. Both the measured and the modelled dose rates verified the fact that the legal limits (<1 mSv a(-1)) are met in the area outside the perimeter fence of the storage building to which members of the public have access. Using container surface data (gamma spectra) to define the source may be a useful tool for practical calculations and additionally for benchmarking of computer codes if the discussed critical aspects with respect to the source can be addressed adequately.

  10. Direct calculation of ice homogeneous nucleation rate for a molecular model of water

    Science.gov (United States)

    Haji-Akbari, Amir; Debenedetti, Pablo G.

    2015-01-01

    Ice formation is ubiquitous in nature, with important consequences in a variety of environments, including biological cells, soil, aircraft, transportation infrastructure, and atmospheric clouds. However, its intrinsic kinetics and microscopic mechanism are difficult to discern with current experiments. Molecular simulations of ice nucleation are also challenging, and direct rate calculations have only been performed for coarse-grained models of water. For molecular models, only indirect estimates have been obtained, e.g., by assuming the validity of classical nucleation theory. We use a path sampling approach to perform, to our knowledge, the first direct rate calculation of homogeneous nucleation of ice in a molecular model of water. We use TIP4P/Ice, the most accurate among existing molecular models for studying ice polymorphs. By using a novel topological approach to distinguish different polymorphs, we are able to identify a freezing mechanism that involves a competition between cubic and hexagonal ice in the early stages of nucleation. In this competition, the cubic polymorph takes over because the addition of new topological structural motifs consistent with cubic ice leads to the formation of more compact crystallites. This is not true for topological hexagonal motifs, which give rise to elongated crystallites that are not able to grow. This leads to transition states that are rich in cubic ice, and not the thermodynamically stable hexagonal polymorph. This mechanism provides a molecular explanation for the earlier experimental and computational observations of the preference for cubic ice in the literature. PMID:26240318

  11. Systematic comparison of ISOLDE-SC yields with calculated in-target production rates

    International Nuclear Information System (INIS)

    Lukic, S.; Gevaert, F.; Kelic, A.; Ricciardi, M.V.; Schmidt, K.H.; Yordanov, O.

    2006-02-01

    Recently, a series of dedicated inverse-kinematics experiments performed at GSI, Darmstadt, has brought an important progress in our understanding of proton and heavy-ion induced reactions at relativistic energies. The nuclear reaction code ABRABLA that has been developed and benchmarked against the results of these experiments has been used to calculate nuclide production cross sections at different energies and with different targets and beams. These calculations are used to estimate nuclide production rates by protons in thick targets, taking into account the energy loss and the attenuation of the proton beam in the target, as well as the low-energy fission induced by the secondary neutrons. The results are compared to the yields of isotopes of various elements obtained from different targets at CERN-ISOLDE with 600 MeV protons, and the overall extraction efficiencies are deduced. The dependence of these extraction efficiencies on the nuclide half-life is found to follow a simple pattern in many different cases. A simple function is proposed to parameterize this behavior in a way that quantifies the essential properties of the extraction efficiency for the element and the target - ion-source system in question. (orig.)

  12. Two computational approaches for Monte Carlo based shutdown dose rate calculation with applications to the JET fusion machine

    Energy Technology Data Exchange (ETDEWEB)

    Petrizzi, L.; Batistoni, P.; Migliori, S. [Associazione EURATOM ENEA sulla Fusione, Frascati (Roma) (Italy); Chen, Y.; Fischer, U.; Pereslavtsev, P. [Association FZK-EURATOM Forschungszentrum Karlsruhe (Germany); Loughlin, M. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxfordshire, OX (United Kingdom); Secco, A. [Nice Srl Via Serra 33 Camerano Casasco AT (Italy)

    2003-07-01

    In deuterium-deuterium (D-D) and deuterium-tritium (D-T) fusion plasmas neutrons are produced causing activation of JET machine components. For safe operation and maintenance it is important to be able to predict the induced activation and the resulting shut down dose rates. This requires a suitable system of codes which is capable of simulating both the neutron induced material activation during operation and the decay gamma radiation transport after shut-down in the proper 3-D geometry. Two methodologies to calculate the dose rate in fusion devices have been developed recently and applied to fusion machines, both using the MCNP Monte Carlo code. FZK has developed a more classical approach, the rigorous 2-step (R2S) system in which MCNP is coupled to the FISPACT inventory code with an automated routing. ENEA, in collaboration with the ITER Team, has developed an alternative approach, the direct 1 step method (D1S). Neutron and decay gamma transport are handled in one single MCNP run, using an ad hoc cross section library. The intention was to tightly couple the neutron induced production of a radio-isotope and the emission of its decay gammas for an accurate spatial distribution and a reliable calculated statistical error. The two methods have been used by the two Associations to calculate the dose rate in five positions of JET machine, two inside the vacuum chamber and three outside, at cooling times between 1 second and 1 year after shutdown. The same MCNP model and irradiation conditions have been assumed. The exercise has been proposed and financed in the frame of the Fusion Technological Program of the JET machine. The scope is to supply the designers with the most reliable tool and data to calculate the dose rate on fusion machines. Results showed that there is a good agreement: the differences range between 5-35%. The next step to be considered in 2003 will be an exercise in which the comparison will be done with dose-rate data from JET taken during and

  13. Two computational approaches for Monte Carlo based shutdown dose rate calculation with applications to the JET fusion machine

    International Nuclear Information System (INIS)

    Petrizzi, L.; Batistoni, P.; Migliori, S.; Chen, Y.; Fischer, U.; Pereslavtsev, P.; Loughlin, M.; Secco, A.

    2003-01-01

    In deuterium-deuterium (D-D) and deuterium-tritium (D-T) fusion plasmas neutrons are produced causing activation of JET machine components. For safe operation and maintenance it is important to be able to predict the induced activation and the resulting shut down dose rates. This requires a suitable system of codes which is capable of simulating both the neutron induced material activation during operation and the decay gamma radiation transport after shut-down in the proper 3-D geometry. Two methodologies to calculate the dose rate in fusion devices have been developed recently and applied to fusion machines, both using the MCNP Monte Carlo code. FZK has developed a more classical approach, the rigorous 2-step (R2S) system in which MCNP is coupled to the FISPACT inventory code with an automated routing. ENEA, in collaboration with the ITER Team, has developed an alternative approach, the direct 1 step method (D1S). Neutron and decay gamma transport are handled in one single MCNP run, using an ad hoc cross section library. The intention was to tightly couple the neutron induced production of a radio-isotope and the emission of its decay gammas for an accurate spatial distribution and a reliable calculated statistical error. The two methods have been used by the two Associations to calculate the dose rate in five positions of JET machine, two inside the vacuum chamber and three outside, at cooling times between 1 second and 1 year after shutdown. The same MCNP model and irradiation conditions have been assumed. The exercise has been proposed and financed in the frame of the Fusion Technological Program of the JET machine. The scope is to supply the designers with the most reliable tool and data to calculate the dose rate on fusion machines. Results showed that there is a good agreement: the differences range between 5-35%. The next step to be considered in 2003 will be an exercise in which the comparison will be done with dose-rate data from JET taken during and

  14. The supply voltage scaled dependency of the recovery of single event upset in advanced complementary metal—oxide—semiconductor static random-access memory cells

    International Nuclear Information System (INIS)

    Li Da-Wei; Qin Jun-Rui; Chen Shu-Ming

    2013-01-01

    Using computer-aided design three-dimensional simulation technology, the supply voltage scaled dependency of the recovery of single event upset and charge collection in static random-access memory cells are investigated. It reveals that the recovery linear energy transfer threshold decreases with the supply voltage reducing, which is quite attractive for dynamic voltage scaling and subthreshold circuit radiation-hardened design. Additionally, the effect of supply voltage on charge collection is also investigated. It is concluded that the supply voltage mainly affects the bipolar gain of the parasitical bipolar junction transistor (BJT) and the existence of the source plays an important role in supply voltage variation. (geophysics, astronomy, and astrophysics)

  15. Accurate Bit Error Rate Calculation for Asynchronous Chaos-Based DS-CDMA over Multipath Channel

    Science.gov (United States)

    Kaddoum, Georges; Roviras, Daniel; Chargé, Pascal; Fournier-Prunaret, Daniele

    2009-12-01

    An accurate approach to compute the bit error rate expression for multiuser chaosbased DS-CDMA system is presented in this paper. For more realistic communication system a slow fading multipath channel is considered. A simple RAKE receiver structure is considered. Based on the bit energy distribution, this approach compared to others computation methods existing in literature gives accurate results with low computation charge. Perfect estimation of the channel coefficients with the associated delays and chaos synchronization is assumed. The bit error rate is derived in terms of the bit energy distribution, the number of paths, the noise variance, and the number of users. Results are illustrated by theoretical calculations and numerical simulations which point out the accuracy of our approach.

  16. Communication: Rate coefficients from quasiclassical trajectory calculations from the reverse reaction: The Mu + H2 reaction re-visited

    Science.gov (United States)

    Homayoon, Zahra; Jambrina, Pablo G.; Aoiz, F. Javier; Bowman, Joel M.

    2012-07-01

    In a previous paper [P. G. Jambrina et al., J. Chem. Phys. 135, 034310 (2011), 10.1063/1.3611400] various calculations of the rate coefficient for the Mu + H2 → MuH + H reaction were presented and compared to experiment. The widely used standard quasiclassical trajectory (QCT) method was shown to overestimate the rate coefficients by several orders of magnitude over the temperature range 200-1000 K. This was attributed to a major failure of that method to describe the correct threshold for the reaction owing to the large difference in zero-point energies (ZPE) of the reactant H2 and product MuH (˜0.32 eV). In this Communication we show that by performing standard QCT calculations for the reverse reaction and then applying detailed balance, the resulting rate coefficient is in very good agreement with the other computational results that respect the ZPE, (as well as with the experiment) but which are more demanding computationally.

  17. ACDOS1: a computer code to calculate dose rates from neutron activation of neutral beamlines and other fusion-reactor components

    International Nuclear Information System (INIS)

    Keney, G.S.

    1981-08-01

    A computer code has been written to calculate neutron induced activation of neutral-beam injector components and the corresponding dose rates as a function of geometry, component composition, and time after shutdown. The code, ACDOS1, was written in FORTRAN IV to calculate both activity and dose rates for up to 30 target nuclides and 50 neutron groups. Sufficient versatility has also been incorporated into the code to make it applicable to a variety of general activation problems due to neutrons of energy less than 20 MeV

  18. A comparison of methods for calculating NMR cross-relaxation rates (NOESY and ROESY intensities) in small peptides

    NARCIS (Netherlands)

    Feenstra, K Anton; Peter, Christine; Scheek, Ruud M; van Gunsteren, Wilfred F; Mark, Alan E

    Three methods for calculating nuclear magnetic resonance cross-relaxation rates from molecular dynamics simulations of small flexible molecules have been compared in terms of their ability to reproduce relaxation data obtained experimentally and to produce consistent descriptions of the system. The

  19. Preliminary results on food consumption rates for off-site dose calculation of nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Gab Bock; Chung, Yang Geun; Bang, Sun Young; Kang, Duk Won

    2005-01-01

    The Internal dose by food consumption mostly account for radiological dose of public around nuclear power plants(NPP). But, food consumption rate applied to off-site dose calculation in Korea which is the result of field investigation around Kori NPP by the KAERI in 1988. is not reflected of the latest dietary characteristics. The Ministry of Health and Welfare Affairs has investigated the food and nutrition of nations every 3 years based on the Law of National Health Improvement. To update the food consumption rates of the maximum individual, the analysis of the national food investigation results and field surveys around nuclear power plant sites have been carried out

  20. Calculation method of rate and area of sedimentation, by non-conventional mathematical process of data treatment

    International Nuclear Information System (INIS)

    Cota, P.L.

    1987-01-01

    The used methods for calculating the rate and area of sedimentation are based in techniques of graphical resolution. The solution of the problem by a mathematical resolution, using computational methods, is more fast and more accuracy. The comparison between the results from this methods and the conventional method is shown. (E.G.) [pt

  1. Ab initio calculation of the transition-state properties and addition rate constants for H + C2H2 and selected isotopic analogues

    International Nuclear Information System (INIS)

    Harding, L.B.; Wagner, A.F.; Bowman, J.M.; Schatz, G.C.; Christoffel, K.

    1982-01-01

    GVB-POL-CI ab initio calculations of the geometries, energetics, and normal mode frequencies of C 2 H 2 , C 2 H 3 , and the transition state for the addition reaction of H + C 2 H 2 are presented. In addition, normal mode frequencies for the isotopic variants D + C 2 D 2 , D + C 2 H 2 , and H + C 2 D 2 are preented. These results are compared to experimental values for C 2 H 2 and to ab initio values of Hagase and Kern, and semiempirical values of Keil, Lynch, Cowfer, and Michael. The results are also used to calculate the apparent bimolecular addition rate constant using conventional RRKM theory for chemical activation. The calculated rate constants and their isotopic variants are compared as a function of temperature and pressure to available experimental information. The agreement is little different from that obtained by Keil et al. with a similar calculation using semiempirical values for acetylene, transition-state, and vinyl radical properties. In particular, the calculated high-pressure limit of the rate constant appears to be at least 1 order of magnitude higher than the experimental limit. Several possible reasons for this discrepancy are discussed

  2. Methods of neutron spectrum calculation from measured reaction rates in SAIPS. Part 2: Software and data input

    International Nuclear Information System (INIS)

    Berzonis, M.A.; Bondars, H.Ya.

    1981-08-01

    A brief description of the SAIPS software and the basic principles of its application is given. SAIPS contains programs needed to unfold spectra, libraries of neutron cross sections and reference spectra, and software for automatic calculation and for system maintenance. SAIPS offers the possibility of determining the reliability of an unfolded neutron spectrum and of planning measurements and calculations by varying different factors: the errors in the reaction rates, the errors in the cross sections used, the detector assembly, the unfolding programs, etc. SAIPS runs on the ES 1022 computer

  3. MCNPX calculations of dose rate distribution inside samples treated in the research gamma irradiating facility at CTEx

    Energy Technology Data Exchange (ETDEWEB)

    Rusin, Tiago; Rebello, Wilson F.; Vellozo, Sergio O.; Gomes, Renato G., E-mail: tiagorusin@ime.eb.b, E-mail: rebello@ime.eb.b, E-mail: vellozo@cbpf.b, E-mail: renatoguedes@ime.eb.b [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Nuclear; Vital, Helio C., E-mail: vital@ctex.eb.b [Centro Tecnologico do Exercito (CTEx), Rio de Janeiro, RJ (Brazil); Silva, Ademir X., E-mail: ademir@con.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Engenharia Nuclear

    2011-07-01

    A cavity-type cesium-137 research irradiating facility at CTEx has been modeled by using the Monte Carlo code MCNPX. The irradiator has been daily used in experiments to optimize the use of ionizing radiation for conservation of many kinds of food and to improve materials properties. In order to correlate the effects of the treatment, average doses have been calculated for each irradiated sample, accounting for the measured dose rate distribution in the irradiating chambers. However that approach is only approximate, being subject to significant systematic errors due to the heterogeneous internal structure of most samples that can lead to large anisotropy in attenuation and Compton scattering properties across the media. Thus this work is aimed at further investigating such uncertainties by calculating the dose rate distribution inside the items treated such that a more accurate and representative estimate of the total absorbed dose can be determined for later use in the effects-versus-dose correlation curves. Samples of different simplified geometries and densities (spheres, cylinders, and parallelepipeds), have been modeled to evaluate internal dose rate distributions within the volume of the samples and the overall effect on the average dose. (author)

  4. MCNPX calculations of dose rate distribution inside samples treated in the research gamma irradiating facility at CTEx

    International Nuclear Information System (INIS)

    Rusin, Tiago; Rebello, Wilson F.; Vellozo, Sergio O.; Gomes, Renato G.; Silva, Ademir X.

    2011-01-01

    A cavity-type cesium-137 research irradiating facility at CTEx has been modeled by using the Monte Carlo code MCNPX. The irradiator has been daily used in experiments to optimize the use of ionizing radiation for conservation of many kinds of food and to improve materials properties. In order to correlate the effects of the treatment, average doses have been calculated for each irradiated sample, accounting for the measured dose rate distribution in the irradiating chambers. However that approach is only approximate, being subject to significant systematic errors due to the heterogeneous internal structure of most samples that can lead to large anisotropy in attenuation and Compton scattering properties across the media. Thus this work is aimed at further investigating such uncertainties by calculating the dose rate distribution inside the items treated such that a more accurate and representative estimate of the total absorbed dose can be determined for later use in the effects-versus-dose correlation curves. Samples of different simplified geometries and densities (spheres, cylinders, and parallelepipeds), have been modeled to evaluate internal dose rate distributions within the volume of the samples and the overall effect on the average dose. (author)

  5. Radiation-hardened MRAM-based LUT for non-volatile FPGA soft error mitigation with multi-node upset tolerance

    Science.gov (United States)

    Zand, Ramtin; DeMara, Ronald F.

    2017-12-01

    In this paper, we have developed a radiation-hardened non-volatile lookup table (LUT) circuit utilizing spin Hall effect (SHE)-magnetic random access memory (MRAM) devices. The design is motivated by modeling the effect of radiation particles striking hybrid complementary metal oxide semiconductor/spin based circuits, and the resistive behavior of SHE-MRAM devices via established and precise physics equations. The models developed are leveraged in the SPICE circuit simulator to verify the functionality of the proposed design. The proposed hardening technique is based on using feedback transistors, as well as increasing the radiation capacity of the sensitive nodes. Simulation results show that our proposed LUT circuit can achieve multiple node upset (MNU) tolerance with more than 38% and 60% power-delay product improvement as well as 26% and 50% reduction in device count compared to the previous energy-efficient radiation-hardened LUT designs. Finally, we have performed a process variation analysis showing that the MNU immunity of our proposed circuit is realized at the cost of increased susceptibility to transistor and MRAM variations compared to an unprotected LUT design.

  6. Simple experimentally derived algorithm for computer calculated dose rates associated with /sup 137/Cs gynecologic insertions

    Energy Technology Data Exchange (ETDEWEB)

    Wrede, D E; Dawalibi, H [King Faisal Specialist Hospital and Research Centre, Department of Medical Physics. Riyadh (Saudi Arabia)

    1980-01-01

    A simple mathematical algorithm is derived from experimental data for dose rates from /sup 137/Cs sources in a finite tissue equivalent medium corresponding to the female pelvis. An analytical expression for a point source of /sup 137/Cs along with a simple numerical integration routine allows for rapid as well as accurate dose rate calculations at points of interest for gynecologic insertions. When compared with theoretical models assuming an infinite unit density medium, the measured dose rates are found to be systematically lower at distances away from a single source; 5 per cent at 2 cm and 10 per cent at 7 cm along the transverse axis. Allowance in the program for print out of dose rates from individual sources to a given point and the feature of source strength modification allows for optimization in terms of increasing the difference in dose rate between reference treatment points and sensitive structures such as the bladder, rectum and colon.

  7. Upset due to a single particle caused propagated transients in a bulk CMOS microprocessor

    International Nuclear Information System (INIS)

    Leavy, J.F.; Hoffmann, L.F.; Shoran, R.W.; Johnson, M.T.

    1991-01-01

    This paper reports on data pattern advances observed in preset, single event upset (SEU) hardened clocked flip-flops, during static Cf-252 exposures on a bulk CMOS microprocessor, that were attributable to particle caused anomalous clock signals, or propagated transients. SPICE simulations established that particle strikes in the output nodes of a clock control logic flip-flop could produce transients of sufficient amplitude and duration to be accepted as legitimate pulses by clock buffers fed by the flip-flop's output nodes. The buffers would then output false clock pulses, thereby advancing the state of the present flip-flops. Masking the clock logic on one of the test chips made the flip-flop data advance cease, confirming the clock logic as the source of the SEU. By introducing N 2 gas, at reduced pressures, into the SEU test chamber to attenuate Cf-252 particle LET's, a 24-26 MeV-cm 2 /mg LET threshold was deduced. Subsequent tests, at the 88-inch cyclotron at Berkeley, established an LET threshold of 30 MeV-cm 2 /mg (283 MeV Cu at 0 degrees) for the generation of false clocks. Cyclotron SEU tests are considered definitive, while Cf-252 data usually is not. However, in this instance Cf-252 tests proved analytically useful, providing SEU characterization data that was both timely and inexpensive

  8. 42 CFR 484.220 - Calculation of the adjusted national prospective 60-day episode payment rate for case-mix and...

    Science.gov (United States)

    2010-10-01

    ... address changes to the case-mix that are a result of changes in the coding or classification of different...-day episode payment rate for case-mix and area wage levels. 484.220 Section 484.220 Public Health... Calculation of the adjusted national prospective 60-day episode payment rate for case-mix and area wage levels...

  9. Estimating the dimensions of the SEU-sensitive volume

    International Nuclear Information System (INIS)

    Abdel-Kader, W.G.; McNulty, P.J.; El-Teleaty, S.; Lynch, J.E.; Khondker, A.N.

    1987-01-01

    Simulations of the diffusion contribution to charge collection in SEU events are carried out under the simple assumption of random walk. The results of the simulation are combined with calculations of the funneling length for the field-assisted drift components to determine the effective thickness of the sensitive volume element to be used in calculations of soft-error rates for heavy-ion-induced and proton-induced upsets in microelectronic circuits. Comparison is made between predicted and measured SEU cross-sections for devices for which the critical charges are known from electrical measurements and the dimensions of the sensitive volume used are determined by the techniques described. The agreement is sufficient to encourage confidence that SEU rates can be calculated from first principles and a knowledge of the material, structural, and electrical characteristics of the device

  10. Multiple cell upset cross-section modeling: A possible interpretation for the role of the ion energy-loss straggling and Auger recombination

    Energy Technology Data Exchange (ETDEWEB)

    Zebrev, G.I., E-mail: gizebrev@mephi.ru; Zemtsov, K.S.

    2016-08-11

    We found that the energy deposition fluctuations in the sensitive volumes may cause the multiple cell upset (MCU) multiplicity scatter in the nanoscale (with feature sizes less than 100 nm) memories. A microdosimetric model of the MCU cross-section dependence on LET is proposed. It was shown that ideally a staircase-shaped cross-section vs LET curve spreads due to the energy-loss straggling impact into a quasi-linear dependence with a slope depending on the memory cell area, the cell critical energy and efficiency of charge collection. This paper also presents a new model of the Auger recombination as a limiting process of the electron–hole charge yield, especially at the high-LET ion impact. A modified form of the MCU cross-section vs LET data interpolation is proposed, discussed and validated.

  11. Multiple cell upset cross-section modeling: A possible interpretation for the role of the ion energy-loss straggling and Auger recombination

    International Nuclear Information System (INIS)

    Zebrev, G.I.; Zemtsov, K.S.

    2016-01-01

    We found that the energy deposition fluctuations in the sensitive volumes may cause the multiple cell upset (MCU) multiplicity scatter in the nanoscale (with feature sizes less than 100 nm) memories. A microdosimetric model of the MCU cross-section dependence on LET is proposed. It was shown that ideally a staircase-shaped cross-section vs LET curve spreads due to the energy-loss straggling impact into a quasi-linear dependence with a slope depending on the memory cell area, the cell critical energy and efficiency of charge collection. This paper also presents a new model of the Auger recombination as a limiting process of the electron–hole charge yield, especially at the high-LET ion impact. A modified form of the MCU cross-section vs LET data interpolation is proposed, discussed and validated.

  12. Calculation of the decay rate of tachyonic neutrinos against charged-lepton-pair and neutrino-pair Cerenkov radiation

    Science.gov (United States)

    Jentschura, Ulrich D.; Nándori, István; Ehrlich, Robert

    2017-10-01

    We consider in detail the calculation of the decay rate of high-energy superluminal neutrinos against (charged) lepton pair Cerenkov radiation, and neutrino pair Cerenkov radiation, i.e., against the decay channels ν \\to ν {e}+ {e}- and ν \\to ν \\overline{ν } ν . Under the hypothesis of a tachyonic nature of neutrinos, these decay channels put constraints on the lifetime of high-energy neutrinos for terrestrial experiments as well as on cosmic scales. For the oncoming neutrino, we use the Lorentz-covariant tachyonic relation {E}ν =\\sqrt{{p}2-{m}ν 2}, where m ν is the tachyonic mass parameter. We derive both threshold conditions as well as on decay and energy loss rates, using the plane-wave fundamental bispinor solutions of the tachyonic Dirac equation. Various intricacies of rest frame versus lab frame calculations are highlighted. The results are compared to the observations of high-energy IceCube neutrinos of cosmological origin.

  13. Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization

    CERN Document Server

    Brugger, Markus; Assmann, R W; Forkel-Wirth, Doris; Menzel, Hans Gregor; Roesler, Stefan; Vincke, Helmut H

    2005-01-01

    Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given examples outline the potential and the need to optimize, in an iterative way, the design of components as well as the layout of ...

  14. Analysis of cosmic ray neutron-induced single-event phenomena

    International Nuclear Information System (INIS)

    Tukamoto, Yasuyuki; Watanabe, Yukinobu; Nakashima, Hideki

    2003-01-01

    We have developed a database of cross sections for the n+ 28 Si reaction in the energy range between 2 MeV and 3 GeV in order to analyze single-event upset (SEU) phenomena induced by cosmic-ray neutrons in semiconductor memory devices. The data are applied to calculations of SEU cross sections using the Burst Generation Rate (BGR) model including two parameters, critical charge and effective depth. The calculated results are compared with measured SEU cross-sections for energies up to 160 MeV, and the reaction products that provide important effects on SEU are mainly investigated. (author)

  15. Single event effects and performance predictions for space applications of RISC processors

    International Nuclear Information System (INIS)

    Kimbrough, J.R.; Colella, N.J.; Denton, S.M.; Shaeffer, D.L.; Shih, D.; Wilburn, J.W.; Coakley, P.G.; Casteneda, C.; Koga, R.; Clark, D.A.; Ullmann, J.L.

    1994-01-01

    Proton and ion Single Event Phenomena (SEP) tests were performed on 32-b processors including R3000A's from all commercial manufacturers along with the Performance PR3400 family, Integrated Device Technology Inc. 79R3081, LSI Logic Corporation LR33000HC, and Intel i80960MX parts. The microprocessors had acceptable upset rates for operation in a low earth orbit or a lunar mission such as CLEMENTINE with a wide range in proton total dose failure. Even though R3000A devices are 60% smaller in physical area than R3000 devices, there was a 340% increase in device Single Event Upset (SEU) cross section. Software tests of varying complexity demonstrate that registers and other functional blocks using register architecture dominate the cross section. The current approach of giving a single upset cross section can lead to erroneous upset rates depending on the application software

  16. First-principles method for calculating the rate constants of internal-conversion and intersystem-crossing transitions.

    Science.gov (United States)

    Valiev, R R; Cherepanov, V N; Baryshnikov, G V; Sundholm, D

    2018-02-28

    A method for calculating the rate constants for internal-conversion (k IC ) and intersystem-crossing (k ISC ) processes within the adiabatic and Franck-Condon (FC) approximations is proposed. The applicability of the method is demonstrated by calculation of k IC and k ISC for a set of organic and organometallic compounds with experimentally known spectroscopic properties. The studied molecules were pyrromethene-567 dye, psoralene, hetero[8]circulenes, free-base porphyrin, naphthalene, and larger polyacenes. We also studied fac-Alq 3 and fac-Ir(ppy) 3 , which are important molecules in organic light emitting diodes (OLEDs). The excitation energies were calculated at the multi-configuration quasi-degenerate second-order perturbation theory (XMC-QDPT2) level, which is found to yield excitation energies in good agreement with experimental data. Spin-orbit coupling matrix elements, non-adiabatic coupling matrix elements, Huang-Rhys factors, and vibrational energies were calculated at the time-dependent density functional theory (TDDFT) and complete active space self-consistent field (CASSCF) levels. The computed fluorescence quantum yields for the pyrromethene-567 dye, psoralene, hetero[8]circulenes, fac-Alq 3 and fac-Ir(ppy) 3 agree well with experimental data, whereas for the free-base porphyrin, naphthalene, and the polyacenes, the obtained quantum yields significantly differ from the experimental values, because the FC and adiabatic approximations are not accurate for these molecules.

  17. Current evaluation of dose rate calculation - analytical method

    International Nuclear Information System (INIS)

    Tello, Marcos; Vilhena, Marco Tulio

    1996-01-01

    The accuracy of the dose calculations based on pencil beam formulas such as Fokker-Plank equations and Fermi equations for charged particle transport are studied and a methodology to solve the Boltzmann transport equation is suggested

  18. Estimating the Number of Heterosexual Persons in the United States to Calculate National Rates of HIV Infection.

    Directory of Open Access Journals (Sweden)

    Amy Lansky

    Full Text Available This study estimated the proportions and numbers of heterosexuals in the United States (U.S. to calculate rates of heterosexually acquired human immunodeficiency virus (HIV infection. Quantifying the burden of disease can inform effective prevention planning and resource allocation.Heterosexuals were defined as males and females who ever had sex with an opposite-sex partner and excluded those with other HIV risks: persons who ever injected drugs and males who ever had sex with another man. We conducted meta-analysis using data from 3 national probability surveys that measured lifetime (ever sexual activity and injection drug use among persons aged 15 years and older to estimate the proportion of heterosexuals in the United States population. We then applied the proportion of heterosexual persons to census data to produce population size estimates. National HIV infection rates among heterosexuals were calculated using surveillance data (cases attributable to heterosexual contact in the numerators and the heterosexual population size estimates in the denominators.Adult and adolescent heterosexuals comprised an estimated 86.7% (95% confidence interval: 84.1%-89.3% of the U.S. population. The estimate for males was 84.1% (CI: 81.2%-86.9% and for females was 89.4% (95% CI: 86.9%-91.8%. The HIV diagnosis rate for 2013 was 5.2 per 100,000 heterosexuals and the rate of persons living with diagnosed HIV infection in 2012 was 104 per 100,000 heterosexuals aged 13 years or older. Rates of HIV infection were >20 times as high among black heterosexuals compared to white heterosexuals, indicating considerable disparity. Rates among heterosexual men demonstrated higher disparities than overall population rates for men.The best available data must be used to guide decision-making for HIV prevention. HIV rates among heterosexuals in the U.S. are important additions to cost effectiveness and other data used to make critical decisions about resources for

  19. Preparation and Properties of Anisotropic Nano-crystalline NdFeB Powders Made by Hydrogen Decrepitation of Die Upsetting Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Yi, P P; Lee, D; Yan, A R, E-mail: ypp@nimte.ac.cn [Ningbo Institute of Material Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China)

    2011-01-01

    Anisotropic nanocrystalline NdFeB powders were prepared by hydrogen decrepitation (HD) of die upsetting magnets. The effects of varying temperatures of HD on the microstructure and magnetic properties of the anisotropic NdFeB particles were studied. It shows that the powders which obtained by HD process at higher temperature were larger than that at lower temperature, and the HD powders show a well anisotropy at 723 K, the remanence (B{sub r}) was more than 12.46 kG, the maximum energy product ((BH){sub max}) was 19.06 MGOe, and the coercivity (H{sub cj}) was 7.2 kOe. The microstructure of the anisotropic powders revealed that with a reasonable HD temperature, the platelet grains were not destroyed. They were nearly 150-300 nm long and 30-50 nm wide. The results indicate that HD process was an effective way to prepare the anisotropic NdFeB powders.

  20. Development of Single-Event Upset hardened programmable logic devices in deep submicron CMOS

    International Nuclear Information System (INIS)

    Bonacini, S.

    2007-11-01

    The electronics associated to the particle detectors of the Large Hadron Collider (LHC), under construction at CERN, will operate in a very harsh radiation environment. Commercial Off-The-Shelf (COTS) components cannot be used in the vicinity of particle collision due to their poor radiation tolerance. This thesis is a contribution to the effort to cover the need for radiation-tolerant SEU-robust (Single Event Upset) programmable components for application in high energy physics experiments. Two components are under development: a Programmable Logic Device (PLD) and a Field-Programmable Gate Array (FPGA). The PLD is a fuse-based, 10-input, 8-I/O general architecture device in 0.25 μm CMOS technology. The FPGA under development is a 32*32 logic block array, equivalent to ∼ 25 k gates, in 0.13 μm CMOS. The irradiation test results obtained in the CMOS 0.25 μm technology demonstrate good robustness of the circuit up to an LET (Linear Energy Transfer) of 79.6 cm 2 *MeV/mg, which make it suitable for the target environment. The CMOS 0.13 μm circuit has showed robustness to an LET of 37.4 cm 2 *MeV/mg in the static test mode and has increased sensitivity in the dynamic test mode. This work focused also on the research for an SEU-robust register in both the mentioned technologies. The SEU-robust register is employed as a user data flip-flop in the FPGA and PLD designs and as a configuration cell as well in the FPGA design

  1. Experimental and simulation study of the effects of cosmic particles on CMOS/SOS RAMs

    International Nuclear Information System (INIS)

    Worley, E.; Williams, R.; Groninger, J.

    1990-01-01

    Van De Graaff particle accelerator data was taken on three different CMOS/SOS RAM cells. The resulting LET upset thresholds were then used to calculate the deposited charge needed to upset the cells. Detailed SPICE simulations of the various cells were used to determine the collected charge required for upset. A comparison of the two values indicated that the charge needed to upset the cells was greater than the deposited charge, thus confirming Rollins' results. Shorter channel lengths and higher power supply voltages caused the ratio, M, of upset charge to deposited charge to increase. As a result of this multiplication factor, actual devices are more likely to upset (i.e., upset at lower energy) than expected from an analysis of only the collected charge. A mixed mode simulator was then used to model the charge collection process. This simulator study showed that the M factor is a very fluid number which is dependent on minority carrier lifetime, drain voltage, and the switching dynamics of the cell in addition to the dependence on mobility ratio and channel length. Parasitic bipolar gain at high injection levels appears to be the primary mechanism allowing collected charge to be greater than deposited charge. In conclusion, the simulator and experimental data show that, as floating body static memory transistors are down scaled, the particle energy needed to upset the cell is reduced because of the enhanced parasitic bipolar gain effect as well as a reduction in the node capacitance. This result is shown by simulation to also apply to fully depleted SOI transistors

  2. Quantum mechanical calculations of state-to-state cross sections and rate constants for the F + DCl → Cl + DF reaction.

    Science.gov (United States)

    Bulut, Niyazi; Kłos, Jacek; Roncero, Octavio

    2015-06-07

    We present accurate state-to-state quantum wave packet calculations of integral cross sections and rate constants for the title reaction. Calculations are carried out on the best available ground 1(2)A' global adiabatic potential energy surface of Deskevich et al. [J. Chem. Phys. 124, 224303 (2006)]. Converged state-to-state reaction cross sections have been calculated for collision energies up to 0.5 eV and different initial rotational and vibrational excitations, DCl(v = 0, j = 0 - 1; v = 1, j = 0). Also, initial-state resolved rate constants of the title reaction have been calculated in a temperature range of 100-400 K. It is found that the initial rotational excitation of the DCl molecule does not enhance reactivity, in contract to the reaction with the isotopologue HCl in which initial rotational excitation produces an important enhancement. These differences between the isotopologue reactions are analyzed in detail and attributed to the presence of resonances for HCl(v = 0, j), absent in the case of DCl(v = 0, j). For vibrational excited DCl(v = 1, j), however, the reaction cross section increases noticeably, what is also explained by another resonance.

  3. The simplified convergence rate calculation for salt grit backfilled caverns in rock salt

    International Nuclear Information System (INIS)

    Navarro, Martin

    2013-03-01

    Within the research and development project 3609R03210 of the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety, different methods were investigated, which are used for the simplified calculation of convergence rates for mining cavities in salt rock that have been backfilled with crushed salt. The work concentrates on the approach of Stelte and on further developments based on this approach. The work focuses on the physical background of the approaches. Model specific limitations are discussed and possibilities for further development are pointed out. Further on, an alternative approach is presented, which implements independent material laws for the convergence of the mining cavity and the compaction of the crushed salt backfill.

  4. A new method for calculating energy release rate in tunnel excavation subjected to high in situ stress

    Directory of Open Access Journals (Sweden)

    Xiao Qinghua

    2016-03-01

    Full Text Available Based on energy theory, energy release rate (EER and local energy release rate (LEER, a new index called FERR (Fractional Energy Release Rate is proposed, and this method can not only evaluate the risk of rock burst, but also can point out the location of high risk and the scale of rockburst. The FERR index is applied to the TBM assembling tunnel in Jinping Hydro Power Station II to evaluate the scale and intensity of rockburst, as well as the location where rockburst occurs. With FDM method adopted, the energy release rate of 3 excavation plans are calculated and the scale and risk of rockburst is evaluated, and the location of high risk of rockburst is also mapped. With FERR used in the evaluation, the rockburst is nicely controlled which ensured the safety and construction schedule of the project.

  5. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO)

    International Nuclear Information System (INIS)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-01-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  6. Activation of the JET vacuum vessel: a comparison of calculated with measured gamma-radiation fluxes and dose rates

    International Nuclear Information System (INIS)

    Jarvis, O.N.; Sadler, G.; Avery, A.; Verschuur, K.A.

    1988-01-01

    The gamma-radiation dose-rates inside the JET vacuum vessel due to induced radioactivity were measured at intervals throughout the 1986 period of operation, and the decay gamma energy spectrum was measured during the subsequent lengthy shutdown. The dose-rates were found to be in good agreement with values calculated using the neutron yield records compiled from the time-resolved neutron yield monitor responses for individual discharges. This result provides strong support for the reliability of the neutron yield monitor calibration. (author)

  7. Neutron-induced Single Event Upset on the RPC front-end chips for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Abbrescia, M.; Colaleo, A.; Iaselli, G.; Loddo, F.; Maggi, M.; Marangelli, B.; Natali, S.; Nuzzo, S.; Pugliese, G.; Ranieri, A.; Romano, F.; Altieri, S.; Belli, G.; Bruno, G.; Guida, R.; Merlo, M.; Ratti, S.P.; Riccardi, C.; Torre, P.; Vitulo, P. E-mail: paolo.vitulo@pv.infn.it; De Bari, A.; Manera, S

    2002-05-21

    Neutrons from a reactor and from a cyclotron have been used to characterise the CMS Resistive Plate Chambers (RPCs) front-end chip to neutron-induced damaging events. Single Event Upset (SEU) cross-sections have been measured up to 60 MeV for different chip thresholds. Tests at a reactor were done with an integrated fast (E{sub n}>3 MeV) neutron fluence of 1.7x10{sup 10} cm{sup -2} and a thermal neutron fluence of 9.5x10{sup 11} cm{sup -2}. High-energy neutrons from a cyclotron were used up to a fluence of 10{sup 12} cm{sup -2}. Data indicate the existence of a chip SEU sensitivity already at thermal energy and a saturated SEU cross-section from 3 to 60 MeV. Values of the SEU cross-sections from the thermal run well agree with those obtained by another CMS group that uses the same technology (0.8 {mu}m BiCMOS) though with different architecture. Cross-sections obtained with fast neutrons (from 3 MeV to about 10 MeV) are consistently higher by one order of magnitude compared to the thermal one. The average time between consecutive SEU events in each chip of the CMS barrel RPCs can be estimated to be 1 h.

  8. Pre- and post-calculations for crack opening and leak rate experiments on piping components within the HDR-program

    International Nuclear Information System (INIS)

    Grebner, H.; Hoefler, A.; Hunger, H.

    1991-01-01

    In this paper calculations to experiments on leak opening and leak rates of piping components are presented. The experiments are performed at the HDR-facility at Karlstein/Germany and up to now straight pipes and pipe branches were considered. Numerical and experimental results are compared. (author)

  9. Comparison of rate theory based modeling calculations with the surveillance test results of Korean light water reactors

    International Nuclear Information System (INIS)

    Lee, Gyeong Geun; Lee, Yong Bok; Kim, Min Chul; Kwon, Junh Yun

    2012-01-01

    Neutron irradiation to reactor pressure vessel (RPV) steels causes a decrease in fracture toughness and an increase in yield strength while in service. It is generally accepted that the growth of point defect cluster (PDC) and copper rich precipitate (CRP) affects radiation hardening of RPV steels. A number of models have been proposed to account for the embrittlement of RPV steels. The rate theory based modeling mathematically described the evolution of radiation induced microstructures of ferritic steels under neutron irradiation. In this work, we compared the rate theory based modeling calculation with the surveillance test results of Korean Light Water Reactors (LWRs)

  10. User's manual of MANYCASK code for calculation of spatial distributions of radiation dose rates in a system composed of many spent-fuel-shipping casks

    International Nuclear Information System (INIS)

    Yamakoshi, Hisao

    1986-01-01

    A calculation code MANYCASK is designed for evaluation of spatial distributions of radiation dose rates in ships loaded with a lot of spent fuel shipping casks. Principle of the calculation method adopted in this code is different from that of ordinary codes, and is advantageous for calculating highly reliable dose rate distributions with a very short calculation time. Basic concept of the principle has been described in other reports in detail. A brief description of the principle will be included in the present report along with a technique named Shadow Technique in this report, in addition to format descriptions of output data as well as input data. Results of sample calculations are compared with measured results in figures so as to show how the calculation method adopted is valid. For the purpose of making this code popular among many people, the author writes the user's manual in the present report in Japanese for domestic users, and in English in another report for people in abroad. (author)

  11. Results of calculations of external gamma radiation exposure rates from fallout and the related radionuclide compositions. Operation Tumbler-Snapper, 1952

    International Nuclear Information System (INIS)

    Hicks, H.G.

    1981-07-01

    This report presents data on calculated gamma radiation exposure rates and ground deposition of related radionuclides resulting from Events that deposited detectable radioactivity outside the Nevada Test Site complex

  12. APPLICATION OF THE SPECTROMETRIC METHOD FOR CALCULATING THE DOSE RATE FOR CREATING CALIBRATION HIGHLY SENSITIVE INSTRUMENTS BASED ON SCINTILLATION DETECTION UNITS

    Directory of Open Access Journals (Sweden)

    R. V. Lukashevich

    2017-01-01

    Full Text Available Devices based on scintillation detector are highly sensitive to photon radiation and are widely used to measure the environment dose rate. Modernization of the measuring path to minimize the error in measuring the response of the detector to gamma radiation has already reached its technological ceiling and does not give the proper effect. More promising for this purpose are new methods of processing the obtained spectrometric information. The purpose of this work is the development of highly sensitive instruments based on scintillation detection units using a spectrometric method for calculating dose rate.In this paper we consider the spectrometric method of dosimetry of gamma radiation based on the transformation of the measured instrumental spectrum. Using predetermined or measured functions of the detector response to the action of gamma radiation of a given energy and flux density, a certain function of the energy G(E is determined. Using this function as the core of the integral transformation from the field to dose characteristic, it is possible to obtain the dose value directly from the current instrumentation spectrum. Applying the function G(E to the energy distribution of the fluence of photon radiation in the environment, the total dose rate can be determined without information on the distribution of radioisotopes in the environment.To determine G(E by Monte-Carlo method instrumental response function of the scintillator detector to monoenergetic photon radiation sources as well as other characteristics are calculated. Then the whole full-scale energy range is divided into energy ranges for which the function G(E is calculated using a linear interpolation.Spectrometric method for dose calculation using the function G(E, which allows the use of scintillation detection units for a wide range of dosimetry applications is considered in the article. As well as describes the method of calculating this function by using Monte-Carlo methods

  13. Predictions of integrated circuit serviceability in space radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Khamidullina, N.M.; Kuznetsov, N.V.; Pichkhadze, K.M.; Popov, V.D

    1999-10-01

    The present paper suggests an approach to estimating and predicting the serviceability of on-board electronic equipment. It is based on the postulates of the reliability theory and accounts for total-dose and single-event radiation effects as well as other exterior destabilizing factors. The methods of determination of failure and upset rates for CMOS devices are considered. The probability of non-failure operation of a two CMOS RAM is calculated along the whole trajectory of the 'Solar Probe' spacecraft.

  14. ESTIMATION OF FLEXIBILITY OF AN ORGANIZATION ON THE GROUND OF THE CALCULATION OF PROFIT MARGIN RATE

    Directory of Open Access Journals (Sweden)

    Olga Gennadevna Rybakova

    2016-12-01

    Full Text Available The article deals with the problem of the flexibility of an organization as the ability to adapt effectively to the external environment. The authors have identified and investigated different approaches to estimating the flexibility of an organization on the ground of flexibility grading, calculation of the general index of flexibility as well as the calculation of flexibility’s ranking score. We have identified the advantages and disadvantages of these approaches. A new method of the estimation of an organization’s flexibility on the ground of the calculation of relative profit margin has been developed. This method is the multifunctional assessment tool of enterprise’s functionability in the current context of difficult and volatile economic environment. It allows in the early stage to identify negative trends in the production and financial figures and thus, it enables the organizational leadership to take steps in advance in order to avert a crisis in its activity. Keeping the profit margin at the same rate at the forced contraction of output, because of the negative impact of external factors, will confirm that the organization has adapted to the external environment and, therefore, it is flexible. The organization can be considered with margin rate beginning to low up to zero value as an organization with an insufficient level of flexibility that is at the “zone of crisis” and it is characterized by the depletion of reserved funds and reduction of current assets. Loss-maker is nonflexible and the presence of loss means that the organization has an evident sign of crisis and it can be bankrupt.

  15. Radioactive cloud dose calculations

    International Nuclear Information System (INIS)

    Healy, J.W.

    1984-01-01

    Radiological dosage principles, as well as methods for calculating external and internal dose rates, following dispersion and deposition of radioactive materials in the atmosphere are described. Emphasis has been placed on analytical solutions that are appropriate for hand calculations. In addition, the methods for calculating dose rates from ingestion are discussed. A brief description of several computer programs are included for information on radionuclides. There has been no attempt to be comprehensive, and only a sampling of programs has been selected to illustrate the variety available

  16. A Physics-Based Engineering Approach to Predict the Cross Section for Advanced SRAMs

    Science.gov (United States)

    Li, Lei; Zhou, Wanting; Liu, Huihua

    2012-12-01

    This paper presents a physics-based engineering approach to estimate the heavy ion induced upset cross section for 6T SRAM cells from layout and technology parameters. The new approach calculates the effects of radiation with junction photocurrent, which is derived based on device physics. The new and simple approach handles the problem by using simple SPICE simulations. At first, the approach uses a standard SPICE program on a typical PC to predict the SPICE-simulated curve of the collected charge vs. its affected distance from the drain-body junction with the derived junction photocurrent. And then, the SPICE-simulated curve is used to calculate the heavy ion induced upset cross section with a simple model, which considers that the SEU cross section of a SRAM cell is more related to a “radius of influence” around a heavy ion strike than to the physical size of a diffusion node in the layout for advanced SRAMs in nano-scale process technologies. The calculated upset cross section based on this method is in good agreement with the test results for 6T SRAM cells processed using 90 nm process technology.

  17. A simple algebraic cancer equation: calculating how cancers may arise with normal mutation rates

    Directory of Open Access Journals (Sweden)

    Shibata Darryl

    2010-01-01

    Full Text Available Abstract Background The purpose of this article is to present a relatively easy to understand cancer model where transformation occurs when the first cell, among many at risk within a colon, accumulates a set of driver mutations. The analysis of this model yields a simple algebraic equation, which takes as inputs the number of stem cells, mutation and division rates, and the number of driver mutations, and makes predictions about cancer epidemiology. Methods The equation [p = 1 - (1 - (1 - (1 - udkNm ] calculates the probability of cancer (p and contains five parameters: the number of divisions (d, the number of stem cells (N × m, the number of critical rate-limiting pathway driver mutations (k, and the mutation rate (u. In this model progression to cancer "starts" at conception and mutations accumulate with cell division. Transformation occurs when a critical number of rate-limiting pathway mutations first accumulates within a single stem cell. Results When applied to several colorectal cancer data sets, parameter values consistent with crypt stem cell biology and normal mutation rates were able to match the increase in cancer with aging, and the mutation frequencies found in cancer genomes. The equation can help explain how cancer risks may vary with age, height, germline mutations, and aspirin use. APC mutations may shorten pathways to cancer by effectively increasing the numbers of stem cells at risk. Conclusions The equation illustrates that age-related increases in cancer frequencies may result from relatively normal division and mutation rates. Although this equation does not encompass all of the known complexity of cancer, it may be useful, especially in a teaching setting, to help illustrate relationships between small and large cancer features.

  18. Parameters calculation of a shielding experiment and evaluation of calculation methodology

    International Nuclear Information System (INIS)

    Gavazza, S.; Otto, A.C.; Gomes, I.C.; Maiorino, J.R.

    1986-01-01

    In this text is carried out the evaluation of radiation transport methodology, comparying the calculated reactions and dose rates, for neutrons and gamma-rays, with the experimental measurements obtained on iron shield, irradiated in YAYOI reactor. Were employed the ENDF/B-IV and VITAMIN-C libraries and the AMPX-II modular system for generation of cross sections, collapsed by the ANISN code. The transport calculation were made by using the DOT 3.5 code, adjusting the spectrum of the iron shield boundary source to the reactions and dose rates, measured at the beginning of shield. The distributions calculated for neutrons and gamma-rays, on iron shield, presented coherence with the experimental measurements. (Author) [pt

  19. Automated calculation of point A coordinates for CT-based high-dose-rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Hyejoo Kang

    2017-07-01

    Full Text Available Purpose: The goal is to develop a stand-alone application, which automatically and consistently computes the coordinates of the dose calculation point recommended by the American Brachytherapy Society (i.e., point A based solely on the implanted applicator geometry for cervical cancer brachytherapy. Material and methods: The application calculates point A coordinates from the source dwell geometries in the computed tomography (CT scans, and outputs the 3D coordinates in the left and right directions. The algorithm was tested on 34 CT scans of 7 patients treated with high-dose-rate (HDR brachytherapy using tandem and ovoid applicators. A single experienced user retrospectively and manually inserted point A into each CT scan, whose coordinates were used as the “gold standard” for all comparisons. The gold standard was subtracted from the automatically calculated points, a second manual placement by the same experienced user, and the clinically used point coordinates inserted by multiple planners. Coordinate differences and corresponding variances were compared using nonparametric tests. Results: Automatically calculated, manually placed, and clinically used points agree with the gold standard to < 1 mm, 1 mm, 2 mm, respectively. When compared to the gold standard, the average and standard deviation of the 3D coordinate differences were 0.35 ± 0.14 mm from automatically calculated points, 0.38 ± 0.21 mm from the second manual placement, and 0.71 ± 0.44 mm from the clinically used point coordinates. Both the mean and standard deviations of the 3D coordinate differences were statistically significantly different from the gold standard, when point A was placed by multiple users (p < 0.05 but not when placed repeatedly by a single user or when calculated automatically. There were no statistical differences in doses, which agree to within 1-2% on average for all three groups. Conclusions: The study demonstrates that the automated algorithm

  20. Calculation of β-decay rates in a relativistic model with momentum-dependent self-energies

    International Nuclear Information System (INIS)

    Marketin, T.; Vretenar, D.; Ring, P.

    2007-01-01

    The relativistic proton-neutron quasiparticle random phase approximation (PN-RQRPA) is applied in the calculation of β-decay half-lives of neutron-rich nuclei in the Z≅28 and Z≅50 regions. The study is based on the relativistic Hartree-Bogoliubov calculation of nuclear ground states, using effective Lagrangians with density-dependent meson-nucleon couplings, and also extended by the inclusion of couplings between the isoscalar meson fields and the derivatives of the nucleon fields. This leads to a linear momentum dependence of the scalar and vector nucleon self-energies. The residual QRPA interaction in the particle-hole channel includes the π+ρ exchange plus a Landau-Migdal term. The finite-range Gogny interaction is employed in the T=1 pairing channel, and the model also includes a proton-neutron particle-particle interaction. The results are compared with available data, and it is shown that an extension of the standard relativistic mean-field framework to include momentum-dependent nucleon self-energies naturally leads to an enhancement of the effective (Landau) nucleon mass, and thus to an improved PN-QRPA description of β - -decay rates

  1. RAHAB calculation of lattice parameters for CANDU-type lattices using Monte Carlo calculations for resolved resonance capture

    International Nuclear Information System (INIS)

    Craig, D.S.; Festarini, G.L.

    1986-07-01

    The Monte Carlo code, REPC, has been used to calculate resonance reaction rates for the thermal test lattices TRX-1 and MIT-4, and for the CRNL lattices ZEEP-1, 19 UO 2 and 37 UO 2 . These reaction rates were used in the RAHAB cell code to calculate k eff , conversion ratios, and fast fission ratios, for comparison with experimental values. The calculations used the cluster geometry for the 19-, 28-, and 37-element clusters. Calculations were also made using annular representations of the cluster for comparison of the rates with those obtained using the discrete ordinate code OZMA

  2. Helium release rates and ODH calculations from RHIC magnet cooling line failure

    Energy Technology Data Exchange (ETDEWEB)

    Liaw, C.J.; Than, Y.; Tuozzolo, J.

    2011-03-28

    A catastrophic failure of the magnet cooling lines, similar to the LHC superconducting bus failure incident, could discharge cold helium into the RHIC tunnel and cause an Oxygen Deficiency Hazard (ODH) problem. A SINDA/FLUINT{reg_sign} model, which simulated the 4.5K/4 atm helium flowing through the magnet cooling system distribution lines, then through a line break into the insulating vacuum volumes and discharging via the reliefs into the RHIC tunnel, had been developed. Arc flash energy deposition and heat load from the ambient temperature cryostat surfaces are included in the simulations. Three typical areas: the sextant arc, the Triplet/DX/D0 magnets, and the injection area, had been analyzed. Results, including helium discharge rates, helium inventory loss, and the resulting oxygen concentration in the RHIC tunnel area, are reported. Good agreement had been achieved when comparing the simulation results, a RHIC sector depressurization test measurement, and some simple analytical calculations.

  3. Calculations for energies, transition rates, and lifetimes in Al-like Kr XXIV

    Science.gov (United States)

    Zhang, C. Y.; Si, R.; Liu, Y. W.; Yao, K.; Wang, K.; Guo, X. L.; Li, S.; Chen, C. Y.

    2018-05-01

    Using the second-order many-body perturbation theory (MBPT) method, a complete and accurate data set of excitation energies, lifetimes, wavelengths, and electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), and magnetic quadrupole (M2) line strengths, transition rates, and oscillator strengths for the lowest 880 levels arising from the 3l3 (0 ≤ l ≤ 2), 3l2 4l‧ (0 ≤ l ≤ 2, 0 ≤l‧ ≤ 3), 3s2 5 l (0 ≤ l ≤ 4), 3p2 5 l (0 ≤ l ≤ 1), and 3s3p5 l (0 ≤ l ≤ 4) configurations in Al-like Kr XXIV is provided. Comparisons are made with available experimental and theoretical results. Our calculated energies are expected to be accurate enough to facilitate identifications of observed lines involving the n = 4 , 5 levels. The complete data set is also useful for modeling and diagnosing fusion plasma.

  4. Calculation of levels, transition rates, and lifetimes for the arsenic isoelectronic sequence Sn XVIII-Ba XXIV, W XLII

    Science.gov (United States)

    Wang, K.; Chen, Z. B.; Chen, C. Y.; Yan, J.; Dang, W.; Zhao, X. H.; Yang, X.

    2017-09-01

    Multi-configuration Dirac-Fock (MCDF) calculations of energy levels, wavelengths, oscillator strengths, lifetimes, and electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), magnetic quadrupole (M2) transition rates are reported for the arsenic isoelectronic sequence Sn XVIII-Ba XXIV, W XLII. Results are presented among the 86 levels of the 4s2 4p3, 4 s 4p4, 4p5, 4s2 4p2 4 d, and 4 s 4p3 4 d configurations in each ion. The relativistic atomic structure package GRASP2K is adopted for the calculations, in which the contributions from the correlations within the n ≤ 7 complexes, Breit interaction (BI) and quantum electrodynamics (QED) effects are taking into account. The many-body perturbation theory (MBPT) method is also employed as an independent calculation for comparison purposes, taking W XLII as an example. Calculated results are compared with data from other calculations and the observed values from the Atomic Spectra Database (ASD) of the National Institute of Standards and Technology (NIST). Good agreements are obtained. i.e, the accuracy of our energy levels is assessed to be better than 0.6%. These accurate theoretical data should be useful for diagnostics of hot plasmas in fusion devices.

  5. Calculation of the dose rate and air ionisation from radioactive fallout deposited at Chilton, Oxon (1951 to 1977)

    International Nuclear Information System (INIS)

    Gibson, J.A.B.

    1978-06-01

    This report is a brief survey of the methods used for calculating the dose rate from deposited fallout and includes improvements in the computing techniques. The changes consist of (a) the use of a more exact allowance for weathering (b) the calculation doses to mid-month rather than end of each month (c) the inclusion of the contribution from Nb-95 in a more exact way to allow for its build-up and decay with time (d) the use of a more precise method for estimating the dose prior to 1954. The result is to increase the calculated total γ-ray dose from 1951 to 1976 by 17% from 153 to 179 mrad in air at 1 m with an increase of 11% in the beta-ray dose. The annual levels for natural γ and β radiation are 12 and 62 mrad respectively. (author)

  6. Resistance Upset Welding of ODS Steel Fuel Claddings—Evaluation of a Process Parameter Range Based on Metallurgical Observations

    Directory of Open Access Journals (Sweden)

    Fabien Corpace

    2017-08-01

    Full Text Available Resistance upset welding is successfully applied to Oxide Dispersion Strengthened (ODS steel fuel cladding. Due to the strong correlation between the mechanical properties and the microstructure of the ODS steel, this study focuses on the consequences of the welding process on the metallurgical state of the PM2000 ODS steel. A range of process parameters is identified to achieve operative welding. Characterizations of the microstructure are correlated to measurements recorded during the welding process. The thinness of the clad is responsible for a thermal unbalance, leading to a higher temperature reached. Its deformation is important and may lead to a lack of joining between the faying surfaces located on the outer part of the join which can be avoided by increasing the dissipated energy or by limiting the clad stick-out. The deformation and the temperature reached trigger a recrystallization phenomenon in the welded area, usually combined with a modification of the yttrium dispersion, i.e., oxide dispersion, which can damage the long-life resistance of the fuel cladding. The process parameters are optimized to limit the deformation of the clad, preventing the compactness defect and the modification of the nanoscale oxide dispersion.

  7. 42 CFR 413.312 - Methodology for calculating rates.

    Science.gov (United States)

    2010-10-01

    ... Determined Payment Rates for Low-Volume Skilled Nursing Facilities, for Cost Reporting Periods Beginning... routine service cost limits; (ii) A wage index to adjust for area wage differences; and (iii) The most... of rates published in the Federal Register under the authority of § 413.320, CMS announces the wage...

  8. Theoretical study and rate constant calculation for the reactions of SH (SD) with Cl2, Br2, and BrCl.

    Science.gov (United States)

    Wang, Li; Liu, Jing-Yao; Li, Ze-Sheng; Sun, Chia-Chung

    2005-01-30

    The mechanisms of the SH (SD) radicals with Cl2 (R1), Br2 (R2), and BrCl (R3) are investigated theoretically, and the rate constants are calculated using a dual-level direct dynamics method. The optimized geometries and frequencies of the stationary points are calculated at the MP2/6-311G(d,p) and MPW1K/6-311G(d,p) levels. Higher-level energies are obtained at the approximate QCISD(T)/6-311++G(3df, 2pd) level using the MP2 geometries as well as by the multicoefficient correlation method based on QCISD (MC-QCISD) using the MPW1K geometries. Complexes with energies less than those of the reactants or products are located at the entrance or the exit channels of these reactions, which indicate that the reactions may proceed via an indirect mechanism. The enthalpies of formation for the species XSH/XSD (X = Cl and Br) are evaluated using hydrogenation working reactions method. By canonical variational transition-state theory (CVT), the rate constants of SH and SD radicals with Cl2, Br2, and BrCl are calculated over a wide temperature range of 200-2000 K at the a-QCISD(T)/6-311++G(3df, 2pd)//MP2/6-311G(d, p) level. Good agreement between the calculated and experimental rate constants is obtained in the measured temperature range. Our calculations show that for SH (SD) + BrCl reaction bromine abstraction (R3a or R3a') leading to the formation of BrSH (BrSD) + Cl in a barrierless process dominants the reaction with the branching ratios for channels 3a and 3a' of 99% at 298 K, which is quite different from the experimental result of k3a'/k3' = 54 +/- 10%. Negative activation energies are found at the higher level for the SH + Br2 and SH + BrCl (Br-abstraction) reactions; as a result, the rate constants show a slightly negative temperature dependence, which is consistent with the determination in the literature. The kinetic isotope effects for the three reactions are "inverse". The values of kH/kD are 0.88, 0.91, and 0.69 at room temperature, respectively, and they increase

  9. Contact conditions in skin-pass rolling

    DEFF Research Database (Denmark)

    Kijima, Hideo; Bay, Niels

    2007-01-01

    The special contact conditions in skin-pass rolling of steel strip is analysed by studying plane strain upsetting of thin sheet with low reduction applying long narrow tools and dry friction conditions. An extended sticking region is estimated by an elasto-plastic FEM analysis of the plane strain...... upsetting. This sticking region causes a highly inhomogeneous elasto-plastic deformation with large influence of work-hardening and friction. A numerical analysis of skin-pass rolling shows the same contact conditions, i.e. an extended sticking region around the center of the contact zone. The calculated...... size of the sticking region with varying contact length and pressure/reduction is experimentally verified by plane strain upsetting tests measuring the local surface deformation of the work pieces after unloading....

  10. Calculation of dose rate in escape channel of Research Irradiating Facility Army Technology Center using code MCNPX

    International Nuclear Information System (INIS)

    Gomes, Renato G.; Rebello, Wilson F.; Vellozo, Sergio O.; Moreira Junior, Luis; Vital, Helio C.; Rusin, Tiago; Silva, Ademir X.

    2013-01-01

    In order to evaluate new lines of research in the area of irradiation of materials external to the research irradiating facility Army Technology Center (CTEx), it is necessary to study security parameters and magnitude of the dose rates from their channels of escape. The objective was to calculate, with the code MCNPX, dose rates (Gy / min) on the interior and exterior of the four-channel leakage gamma irradiator. The channels were designed to leak radiation on materials properly disposed in the area outside the irradiator larger than the expected volume of irradiation chambers (50 liters). This study aims to assess the magnitude of dose rates within the channels, as well as calculate the angle of beam output range outside the channel for analysis as to its spread, and evaluation of safe conditions of their operators (protection radiological). The computer simulation was performed by distributing virtual dosimeter ferrous sulfate (Fricke) in the longitudinal axis of the vertical drain channels (anterior and posterior) and horizontal (top and bottom). The results showed a collimating the beams irradiated on each of the channels to the outside, with values of the order of tenths of Gy / min as compared to the maximum amount of operation of the irradiator chamber (33 Gy / min). The external beam irradiation in two vertical channels showed a distribution shaped 'trunk pyramid', not collimated, so scattered, opening angle 83 ° in the longitudinal direction and 88 in the transverse direction. Thus, the cases allowed the evaluation of materials for irradiation outside the radiator in terms of the magnitude of the dose rates and positioning of materials, and still be able to take the necessary care in mounting shield for radiation protection by operators, avoiding exposure to ionizing radiation. (author)

  11. The impact of meal timing on performance, sleepiness, gastric upset, and hunger during simulated night shift.

    Science.gov (United States)

    Grant, Crystal Leigh; Dorrian, Jillian; Coates, Alison Maree; Pajcin, Maja; Kennaway, David John; Wittert, Gary Allen; Heilbronn, Leonie Kaye; Vedova, Chris Della; Gupta, Charlotte Cecilia; Banks, Siobhan

    2017-10-07

    This study examined the impact of eating during simulated night shift on performance and subjective complaints. Subjects were randomized to eating at night (n=5; 23.2 ± 5.5 y) or not eating at night (n=5; 26.2 ± 6.4 y). All participants were given one sleep opportunity of 8 h (22:00 h-06:00 h) before transitioning to the night shift protocol. During the four days of simulated night shift participants were awake from 16:00 h-10:00 h with a daytime sleep of 6 h (10:00 h-16:00 h). In the simulated night shift protocol, meals were provided at ≈0700 h, 1900 h and 0130 h (eating at night); or ≈0700 h, 0930 h, 1410 h and 1900 h (not eating at night). Subjects completed sleepiness, hunger and gastric complaint scales, a Digit Symbol Substitution Task and a 10-min Psychomotor Vigilance Task. Increased sleepiness and performance impairment was evident in both conditions at 0400 h (phunger and a small but significant elevation in stomach upset across the night (p<0.026). Eating at night was associated with elevated bloating on night one, which decreased across the protocol. Restricting food intake may limit performance impairments at night. Dietary recommendations to improve night-shift performance must also consider worker comfort.

  12. Monte carlo calculation of the neutron effective dose rate at the outer surface of the biological shield of HTR-10 reactor

    International Nuclear Information System (INIS)

    Remetti, Romolo; Andreoli, Giulio; Keshishian, Silvina

    2012-01-01

    Highlights: ► We deal with HTR-10, that is a helium-cooled graphite-moderated pebble bed reactor. ► We carried out Monte Carlo simulation of the core by MCNP5. ► Extensive use of MCNP5 variance reduction methods has been done. ► We calculated the trend of neutron flux within the biological shield. ► We calculated neutron effective dose at the outer surface of biological shield. - Abstract: Research on experimental reactors, such as HTR-10, provide useful data about potentialities of very high temperature gas-cooled reactors (VHTR). The latter is today rated as one of the six nuclear reactor types involved in the Generation-IV International Forum (GIF) Initiative. In this study, the MCNP5 code has been employed to evaluate the neutron radiation trend vs. the biological shield's thickness and to calculate the neutron effective dose rate at the outer surface. The reactor's geometry has been completely modeled by means of lattices and universes provided by MCNP, even though some approximations were required. Monte Carlo calculations have been performed by means of a simple PC and, as a consequence, in order to obtain acceptable run times, it was made an extensive recourse to variance reduction methods.

  13. Experimental validation of calculated capture rate for nucleus involved in fuel cycle

    International Nuclear Information System (INIS)

    Benslimane-Bouland, A.

    1997-09-01

    The framework of this study was the evaluation of the nuclear data requirements for Actinides and Fission Products applied to current nuclear reactors as well as future applications. This last item includes extended irradiation campaigns, 100 % Mixed Oxide fuel, transmutation or even incineration. The first part of this study presents different types of integral measurements which are available for capture rate measurements, as well as the methods used for reactor core calculation route design and nuclear data library validation. The second section concerns the analysis of three specific irradiation experiments. The results have shown the extent of the current knowledge on nuclear data as well as the associated uncertainties. The third and last section shows both the coherency between all the results, and the statistical method applied for nuclear data library adjustment. A relevant application of this method has demonstrated that only specifically chosen integral experiments can be of use for the validation of nuclear data libraries. The conclusion is reached that even if co-ordinated efforts between reactor and nuclear physicists have made possible a huge improvement in the knowledge of capture cross sections of the main nuclei such as uranium and plutonium, some improvements are currently necessary for the minor actinides (Np, Am and Cm). Both integral and differential measurements are recommended to improve the knowledge of minor actinide cross sections. As far as integral experiments are concerned, a set of criteria to be followed during the experimental conception have been defined in order to both reduce the number of required calculation approximations, and to increase as much as possible the maximum amount of extracted information. (author)

  14. COMPARISON OF GKS CALCULATED CRITICAL ION TEMPERATURE GRADIENTS AND ITG GROWTH RATES TO DIII-D MEASURED GRADIENTS AND DIFFUSIVITIES

    International Nuclear Information System (INIS)

    BAKER, DR; STAEBLER, GM; PETTY, CC; GREENFIELD, CM; LUCE, TC

    2003-01-01

    OAK-B135 The gyrokinetic equations predict that various drift type waves or modes can be unstable in a tokamak. For some of these modes, such as the ion temperature gradient (ITG) mode and the electron temperature gradient mode, there exists a critical gradient, above which the mode is unstable. Since the existence of unstable modes can cause increased transport, plasmas which are centrally heated tend to increase in temperature gradient until the modes become unstable. Under some conditions the increased transport can fix the gradient at the critical value. here they present a comparison between the measured ion temperature gradients and the critical gradient as calculated by a gyrokinetic linear stability (GKS) code. They also present the maximum linear growth rate as calculated by this code for comparison to experimentally derived transport coefficients. The results show that for low confinement mode (L-mode) discharges, the measured ion temperature gradient is significantly greater than the GKS calculated critical gradient over a large region of the plasma. This is the same region of the plasma where the ion thermal diffusivity is large. For high confinement mode (H-mode) discharges the ion temperature gradient is closer to the critical gradient, but often still greater than the critical gradient over some region. For the best H-mode discharges, the ion temperature is less than or equal to the critical gradient over the whole plasma. In general they find that the position in the plasma where the ion thermal diffusivity starts to increase rapidly is where the maximum linear growth rate is greater than the E x B shearing rate

  15. An alternative radiometric method for calculating the sedimentation rates: Application to an intertidal region (SW of Spain)

    Energy Technology Data Exchange (ETDEWEB)

    Ligero, R.A., E-mail: rufino.ligero@uca.e [Departamento de Fisica Aplicada, Universidad de Cadiz, 11510 Puerto Real, Cadiz (Spain); Casas-Ruiz, M. [Departamento de Fisica Aplicada, Universidad de Cadiz, 11510 Puerto Real, Cadiz (Spain); Barrera, M. [Departamento de Medio Ambiente, CIEMAT, Madrid 28040 (Spain); Barbero, L. [Departamento de Ciencias de la Tierra, Universidad de Cadiz, 11510 Puerto Real (Spain); Melendez, M.J. [Departamento de Fisica Aplicada, Universidad de Cadiz, 11510 Puerto Real, Cadiz (Spain)

    2010-09-15

    A new method using the inventory determined for the activity of the radionuclide {sup 137}Cs, coming from global radioactive fallout has been utilised to calculate the sedimentation rates. The method has been applied in a wide intertidal region in the Bay of Cadiz Natural Park (SW Spain). The sedimentation rates estimated by the {sup 137}Cs inventory method ranged from 0.26 cm/year to 1.72 cm/year. The average value of the sedimentation rate obtained is 0.59 cm/year, and this rate has been compared with those resulting from the application of the {sup 210}Pb dating technique. A good agreement between the two procedures has been found. From the study carried out, it has been possible for the first time, to draw a map of sedimentation rates for this zone where numerous physico-chemical, oceanographic and ecological studies converge, since it is situated in a region of great environmental interest. This area, which is representative of common environmental coastal scenarios, is particularly sensitive to perturbations related to climate change, and the results of the study will allow to make short and medium term evaluations of this change.

  16. Accelerated testing for cosmic soft-error rate

    International Nuclear Information System (INIS)

    Ziegler, J.F.; Muhlfeld, H.P.; Montrose, C.J.; Curtis, H.W.; O'Gorman, T.J.; Ross, J.M.

    1996-01-01

    This paper describes the experimental techniques which have been developed at IBM to determine the sensitivity of electronic circuits to cosmic rays at sea level. It relates IBM circuit design and modeling, chip manufacture with process variations, and chip testing for SER sensitivity. This vertical integration from design to final test and with feedback to design allows a complete picture of LSI sensitivity to cosmic rays. Since advanced computers are designed with LSI chips long before the chips have been fabricated, and the system architecture is fully formed before the first chips are functional, it is essential to establish the chip reliability as early as possible. This paper establishes techniques to test chips that are only partly functional (e.g., only 1Mb of a 16Mb memory may be working) and can establish chip soft-error upset rates before final chip manufacturing begins. Simple relationships derived from measurement of more than 80 different chips manufactured over 20 years allow total cosmic soft-error rate (SER) to be estimated after only limited testing. Comparisons between these accelerated test results and similar tests determined by ''field testing'' (which may require a year or more of testing after manufacturing begins) show that the experimental techniques are accurate to a factor of 2

  17. Measurement of the double differential dijet rate in deep inelastic scattering at HERA and comparison to NLO QCD calculations

    International Nuclear Information System (INIS)

    Poeschl, R.

    2000-12-01

    The analysis presented the measurement of the dijet rate R 2 , the fraction of dijet events in all DIS events, as a function of the kinematic variables x B and Q 2 in the range of 5 2 2 and 10 -4 B -2 . The analysis is based on data collected with the H1 detector in the years 1996/97. The large amount of integrated luminosity (21.9 pb -1 ) available for this analysis allowed for the first time a double differential measurement of R 2 as a function of both x B and Q 2 . The single differential dijet rate, R 2 (x B ) and R 2 (Q 2 ), increases for increasing Q 2 as well as for increasing x B . The double differential dijet rate R 2 (x B , Q 2 ) is more sensitive to the x B dependence of dijet production since it shows a strong increase towards small values of x B if Q 2 is kept fixed. The double differential dijet rate has been compared to predictions of NLO QCD calculations. For the comparison it is required that at least one of the jets has a transverse energy 5 + Δ GeV where Δ = 2 GeV was chosen to be the central cut scenario. The dijet rate is well described by NLO calculations when μ r 2 = Q 2 is chosen as the renormalization scale albeit at the cost of large scale uncertainties. If, however, μ r 2 = Q 2 + E t 2 is chosen, which considerable reduces the scale uncertainties, substantial contributions from other sources of dijet production are needed. (orig.)

  18. Shielding calculational system for plutonium

    International Nuclear Information System (INIS)

    Zimmerman, M.G.; Thomsen, D.H.

    1975-08-01

    A computer calculational system has been developed and assembled specifically for calculating dose rates in AEC plutonium fabrication facilities. The system consists of two computer codes and all nuclear data necessary for calculation of neutron and gamma dose rates from plutonium. The codes include the multigroup version of the Battelle Monte Carlo code for solution of general neutron and gamma shielding problems and the PUSHLD code for solution of shielding problems where low energy gamma and x-rays are important. The nuclear data consists of built in neutron and gamma yields and spectra for various plutonium compounds, an automatic calculation of age effects and all cross-sections commonly used. Experimental correlations have been performed to verify portions of the calculational system. (23 tables, 7 figs, 16 refs) (U.S.)

  19. Use of nuclear data for space and aeronautic designs

    International Nuclear Information System (INIS)

    Palau, M.C.; Carriere, Th.; Buard, B.; Weulersse, C.; Saigne, F.; Wrobel, F.

    2008-01-01

    Until recently, the effects of radiation environment on on-board electronics on launchers and aircraft had not been seriously taken into account. The situation has changed. And one of the most significant effects observed on on-board electronics is what we call Single Event Upset (SEU). This talk explains how the combination of electrical sensitivity of components and nuclear physics is important in the calculation of SEU rates, and emphasizes the aspects of nuclear physics useful to give the probability for a dangerous event to occur. Some circumvention methods will be rapidly identified. (authors)

  20. Use of nuclear data for space and aeronautic designs

    Energy Technology Data Exchange (ETDEWEB)

    Palau, M.C.; Carriere, Th. [Astrium ST, 78 - Les Mureaux (France); Buard, B.; Weulersse, C. [EADS IN, 92 - Suresnes (France); Saigne, F. [CEM2, 34 - Montpellier (France); Wrobel, F. [Nice Univ., LPES (France)

    2008-07-01

    Until recently, the effects of radiation environment on on-board electronics on launchers and aircraft had not been seriously taken into account. The situation has changed. And one of the most significant effects observed on on-board electronics is what we call Single Event Upset (SEU). This talk explains how the combination of electrical sensitivity of components and nuclear physics is important in the calculation of SEU rates, and emphasizes the aspects of nuclear physics useful to give the probability for a dangerous event to occur. Some circumvention methods will be rapidly identified. (authors)

  1. Database crime to crime match rate calculation.

    Science.gov (United States)

    Buckleton, John; Bright, Jo-Anne; Walsh, Simon J

    2009-06-01

    Guidance exists on how to count matches between samples in a crime sample database but we are unable to locate a definition of how to estimate a match rate. We propose a method that does not proceed from the match counting definition but which has a strong logic.

  2. Model to calculate mass flow rate and other quantities of two-phase flow in a pipe with a densitometer, a drag disk, and a turbine meter

    International Nuclear Information System (INIS)

    Aya, I.

    1975-11-01

    The proposed model was developed at ORNL to calculate mass flow rate and other quantities of two-phase flow in a pipe when the flow is dispersed with slip between the phases. The calculational model is based on assumptions concerning the characteristics of a turbine meter and a drag disk. The model should be validated with experimental data before being used in blowdown analysis. In order to compare dispersed flow and homogeneous flow, the ratio of readings from each flow regime for each device discussed is calculated for a given mass flow rate and steam quality. The sensitivity analysis shows that the calculated flow rate of a steam-water mixture (based on the measurements of a drag disk and a gamma densitometer in which the flow is assumed to be homogeneous even if there is some slip between phases) is very close to the real flow rate in the case of dispersed flow at a low quality. As the steam quality increases at a constant slip ratio, all models are prone to overestimate. At 20 percent quality the overestimates reach 8 percent in the proposed model, 15 percent in Rouhani's model, 38 percent in homogeneous model, and 75 percent in Popper's model

  3. Calculation of activity concentration and dose rates from online radioactivity measurement in primary coolant channel of TAPS-III and IV

    International Nuclear Information System (INIS)

    Chaudhury, Sanhita; Agarwal, Chhavi; Goswami, A.; Mhatre, Amol; Chaturvedi, T.P.; Tawde, N.; Gathibandhe, Manohar; Dash, S.C.

    2011-05-01

    Radioactivity measurement using CdZnTe detector and dose measurement using teletector were done at several locations of primary heat transport (PHT) system of the Tarapur Atomic Power Station-III and IV reactor during shut down as well as operating condition of the reactors. The detector efficiency for the required counting geometry was simulated using MCNP code. Using this simulated efficiency and the experimental count rate (cps), the activity concentrations (Bq/mL) of different radionuclides in coolant water were calculated. The dose rates for the counted locations were also simulated using Monte Carlo code and it matched well with the experimentally obtained dose rate. (author)

  4. Cross section for calculating the helium formation rate in construction materials irradiated by nucleons at energies to 800 MeV

    International Nuclear Information System (INIS)

    Konobeev, A.Yu.; Korovin, Yu.A.

    1992-01-01

    Recently, effects related to the formation of helium in irradiated construction materials have been studied extensively. Data on the nuclear cross sections for producing helium in these materials form the initial information necessary for such investigations. If the spectrum of the incoming particles is known, the value of the helium production cross section makes it possible to calculate the helium generation rate. In recent years, plans and simulating experiments on radiating materials with high-energy particles made it necessary to determine the helium production cross sections in constructionmaterials, which are irradiated by protons and neutrons with energies to 800 MeV. Helium-formation cross sections have been calculated at these energies. However, a correct description of the experimental data for various construction materials does not yet exist. For example, the calculated helium-formation cross sections turned out to overestimate the experimental data, and to underestimate the experimental data. The objective here is to calculate the helium-formation cross sections for various construction materials, which are irradiated by protons and neutrons to energies from 20 to 800 MeV, and to analyze the probable causes of deviations between experimental and earlier calculated cross sections

  5. Validation of absolute axial neutron flux distribution calculations with MCNP with 197Au(n,γ)198Au reaction rate distribution measurements at the JSI TRIGA Mark II reactor.

    Science.gov (United States)

    Radulović, Vladimir; Štancar, Žiga; Snoj, Luka; Trkov, Andrej

    2014-02-01

    The calculation of axial neutron flux distributions with the MCNP code at the JSI TRIGA Mark II reactor has been validated with experimental measurements of the (197)Au(n,γ)(198)Au reaction rate. The calculated absolute reaction rate values, scaled according to the reactor power and corrected for the flux redistribution effect, are in good agreement with the experimental results. The effect of different cross-section libraries on the calculations has been investigated and shown to be minor. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Steady-State Flammable Gas Release Rate Calculation And Lower Flammability Level Evaluation For Hanford Tank Waste

    International Nuclear Information System (INIS)

    Meacham, J.E.

    2008-01-01

    This report assesses the steady state flammability level under off normal ventilation conditions in the tank headspace for 28 double-shell tanks (DST) and 149 single shell-tanks (SST) at the Hanford Site. Flammability was calculated using estimated gas release rates, Le Chatelier's rule, and lower flammability limits of fuels in an air mixture. This revision updates the hydrogen generation rate input data for al1 177 tanks using waste composition information from the Best Basis Inventory Detail Report (data effective as of August 4,2008). Assuming only barometric breathing, the shortest time to reach 25% of the lower flammability limit is 13 days for DSTs (i.e., tank 241-AZ-102) and 36 days for SSTs (i.e., tank 241-B-203). Assuming zero ventilation, the shortest time to reach 25% of the lower flammability limit is 12 days for DSTs (i.e., tank 241-AZ-102) and 34 days for SSTs (i.e., tank 241-B-203).

  7. Steady-State Flammable Gas Release Rate Calculation And Lower Flammability Level Evaluation For Hanford Tank Waste

    International Nuclear Information System (INIS)

    Meacham, J.E.

    2009-01-01

    This report assesses the steady state flammability level under off normal ventilation conditions in the tank headspace for 28 double-shell tanks (DST) and 149 single shell-tanks (SST) at the Hanford Site. Flammability was calculated using estimated gas release rates, Le Chatelier's rule, and lower flammability limits of fuels in an air mixture. This revision updates the hydrogen generation rate input data for all 177 tanks using waste composition information from the Best Basis Inventory Detail Report (data effective as of August 4,2008). Assuming only barometric breathing, the shortest time to reach 25% of the lower flammability limit is 11 days for DSTs (i.e., tank 241-AZ-10l) and 36 days for SSTs (i.e., tank 241-B-203). Assuming zero ventilation, the shortest time to reach 25% of the lower flammability limit is 10 days for DSTs (i.e., tank 241-AZ-101) and 34 days for SSTs (i.e., tank 241-B-203).

  8. Ammonia synthesis from first principles calculations

    DEFF Research Database (Denmark)

    Honkala, Johanna Karoliina; Hellman, Anders; Remediakis, Ioannis

    2005-01-01

    . When the size distribution of ruthenium particles measured by transmission electron microscopy was used as the [ink between the catalyst material and the theoretical treatment, the calculated rate was within a factor of 3 to 20 of the experimental rate. This offers hope for computer-based methods......The rate of ammonia synthesis over a nanoparticle ruthenium catalyst can be calculated directly on the basis of a quantum chemical treatment of the problem using density functional theory. We compared the results to measured rates over a ruthenium catalyst supported on magnesium aluminum spinet...

  9. Benchmark calculation of subchannel analysis codes

    International Nuclear Information System (INIS)

    1996-02-01

    In order to evaluate the analysis capabilities of various subchannel codes used in thermal-hydraulic design of light water reactors, benchmark calculations were performed. The selected benchmark problems and major findings obtained by the calculations were as follows: (1)As for single-phase flow mixing experiments between two channels, the calculated results of water temperature distribution along the flow direction were agreed with experimental results by tuning turbulent mixing coefficients properly. However, the effect of gap width observed in the experiments could not be predicted by the subchannel codes. (2)As for two-phase flow mixing experiments between two channels, in high water flow rate cases, the calculated distributions of air and water flows in each channel were well agreed with the experimental results. In low water flow cases, on the other hand, the air mixing rates were underestimated. (3)As for two-phase flow mixing experiments among multi-channels, the calculated mass velocities at channel exit under steady-state condition were agreed with experimental values within about 10%. However, the predictive errors of exit qualities were as high as 30%. (4)As for critical heat flux(CHF) experiments, two different results were obtained. A code indicated that the calculated CHF's using KfK or EPRI correlations were well agreed with the experimental results, while another code suggested that the CHF's were well predicted by using WSC-2 correlation or Weisman-Pei mechanistic model. (5)As for droplets entrainment and deposition experiments, it was indicated that the predictive capability was significantly increased by improving correlations. On the other hand, a remarkable discrepancy between codes was observed. That is, a code underestimated the droplet flow rate and overestimated the liquid film flow rate in high quality cases, while another code overestimated the droplet flow rate and underestimated the liquid film flow rate in low quality cases. (J.P.N.)

  10. Hot-electron-mediated desorption rates calculated from excited-state potential energy surfaces

    DEFF Research Database (Denmark)

    Olsen, Thomas; Gavnholt, Jeppe; Schiøtz, Jakob

    2009-01-01

    We present a model for desorption induced by (multiple) electronic transitions [DIET (DIMET)] based on potential energy surfaces calculated with the delta self-consistent field extension of density-functional theory. We calculate potential energy surfaces of CO and NO molecules adsorbed on variou...

  11. COSANI-2, Gamma Doses from SABINE Calculation, Activity from ANISN Flux Calculation

    International Nuclear Information System (INIS)

    Dupont, C.

    1975-01-01

    1 - Nature of physical problem solved: Retrieval of SABINE and/or ANISN results. Calculates in case of SABINE results the individual contributions of capture gamma rays in each region to the total gamma dose and to the total gamma heating may calculate in case of ANISN new activity rates starting from ANISN flux saved on tape and activity cross sections taken on an ANISN binary library tape. The program can draw on a BENSON plotter any of the following quantities: - group flux; - activity rates; - dose rates; - neutron spectra for SABINE; - neutron or gamma direct or adjoint spectra for ANISN; - gamma heating and dose rate for SABINE including individual contributions from each region. Several ANISN and/or SABINE cases can be drawn on the same graph for comparison purposes. 2 - Restrictions on the complexity of the problem: Maximum number of: - tapes containing ANISN and/or SABINE results: 5; - curves per graph: 3; - regions: 40; - points per curve: 500; - energy groups: 200

  12. Resolution of the inverse problem of radioactive decay for the calculation of dose flow rate in radioprotection; Resolution du probleme inverse de la decroissance radioactive pour le calcul de debit de dose en radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    Bonin, A.; Tsilanizara, A. [CEA Saclay, LIST, DENIDANSIDM2SISERMA, 91 - Gif-sur-Yvette (France)

    2010-07-01

    The authors present a method for the calculation of the dose equivalent rate which takes main isotopes as well as minority isotopes into account. According to this method, they first calculate the initial composition (before ageing) from what can be observed at a certain time. Then, from this reconstructed initial composition, they complete the isotopic assessment, thus the sources of emitted particles at the same time. The method is implemented in the MENDEL code. Validation is performed with data corresponding to an UOX fuel pin

  13. Calculation and Analysis of B/T (Burning and/or Transmutation Rate of Minor Actinides and Plutonium Performed by Fast B/T Reactor

    Directory of Open Access Journals (Sweden)

    Marsodi

    2006-01-01

    Full Text Available Calculation and analysis of B/T (Burning and/or Transmutation rate of MA (minor actinides and Pu (Plutonium has been performed in fast B/T reactor. The study was based on the assumption that the spectrum shift of neutron flux to higher side of neutron energy had a potential significance for designing the fast B/T reactor and a remarkable effect for increasing the B/T rate of MA and/or Pu. The spectrum shifts of neutron have been performed by change MOX to metallic fuel. Blending fraction of MA and or Pu in B/T fuel and the volume ratio of fuel to coolant in the reactor core were also considered. Here, the performance of fast B/T reactor was evaluated theoretically based on the calculation results of the neutronics and burn-up analysis. In this study, the B/T rate of MA and/or Pu increased by increasing the blending fraction of MA and or Pu and by changing the F/C ratio. According to the results, the total B/T rate, i.e. [B/T rate]MA + [B/T rate]Pu, could be kept nearly constant under the critical condition, if the sum of the MA and Pu inventory in the core is nearly constant. The effect of loading structure was examined for inner or outer loading of concentric geometry and for homogeneous loading. Homogeneous loading of B/T fuel was the good structure for obtaining the higher B/T rate, rather than inner or outer loading

  14. FinFET memory cell improvements for higher immunity against single event upsets

    Science.gov (United States)

    Sajit, Ahmed Sattar

    The 21st century is witnessing a tremendous demand for transistors. Life amenities have incorporated the transistor in every aspect of daily life, ranging from toys to rocket science. Day by day, scaling down the transistor is becoming an imperious necessity. However, it is not a straightforward process; instead, it faces overwhelming challenges. Due to these scaling changes, new technologies, such as FinFETs for example, have emerged as alternatives to the conventional bulk-CMOS technology. FinFET has more control over the channel, therefore, leakage current is reduced. FinFET could bridge the gap between silicon devices and non-silicon devices. The semiconductor industry is now incorporating FinFETs in systems and subsystems. For example, Intel has been using them in their newest processors, delivering potential saving powers and increased speeds to memory circuits. Memory sub-systems are considered a vital component in the digital era. In memory, few rows are read or written at a time, while the most rows are static; hence, reducing leakage current increases the performance. However, as a transistor shrinks, it becomes more vulnerable to the effects from radioactive particle strikes. If a particle hits a node in a memory cell, the content might flip; consequently, leading to corrupting stored data. Critical fields, such as medical and aerospace, where there are no second chances and cannot even afford to operate at 99.99% accuracy, has induced me to find a rigid circuit in a radiated working environment. This research focuses on a wide spectrum of memories such as 6T SRAM, 8T SRAM, and DICE memory cells using FinFET technology and finding the best platform in terms of Read and Write delay, susceptibility level of SNM, RSNM, leakage current, energy consumption, and Single Event Upsets (SEUs). This research has shown that the SEU tolerance that 6T and 8T FinFET SRAMs provide may not be acceptable in medical and aerospace applications where there is a very high

  15. Formulation of a strategy for monitoring control integrity in critical digital control systems

    Science.gov (United States)

    Belcastro, Celeste M.; Fischl, Robert; Kam, Moshe

    1991-01-01

    Advanced aircraft will require flight critical computer systems for stability augmentation as well as guidance and control that must perform reliably in adverse, as well as nominal, operating environments. Digital system upset is a functional error mode that can occur in electromagnetically harsh environments, involves no component damage, can occur simultaneously in all channels of a redundant control computer, and is software dependent. A strategy is presented for dynamic upset detection to be used in the evaluation of critical digital controllers during the design and/or validation phases of development. Critical controllers must be able to be used in adverse environments that result from disturbances caused by an electromagnetic source such as lightning, high intensity radiated field (HIRF), and nuclear electromagnetic pulses (NEMP). The upset detection strategy presented provides dynamic monitoring of a given control computer for degraded functional integrity that can result from redundancy management errors and control command calculation error that could occur in an electromagnetically harsh operating environment. The use is discussed of Kalman filtering, data fusion, and decision theory in monitoring a given digital controller for control calculation errors, redundancy management errors, and control effectiveness.

  16. Piloted Simulator Evaluation Results of Flight Physics Based Stall Recovery Guidance

    Science.gov (United States)

    Lombaerts, Thomas; Schuet, Stefan; Stepanyan, Vahram; Kaneshige, John; Hardy, Gordon; Shish, Kimberlee; Robinson, Peter

    2018-01-01

    In recent studies, it has been observed that loss of control in flight is the most frequent primary cause of accidents. A significant share of accidents in this category can be remedied by upset prevention if possible, and by upset recovery if necessary, in this order of priorities. One of the most important upsets to be recovered from is stall. Recent accidents have shown that a correct stall recovery maneuver remains a big challenge in civil aviation, partly due to a lack of pilot training. A possible strategy to support the flight crew in this demanding context is calculating a recovery guidance signal, and showing this signal in an intuitive way on one of the cockpit displays, for example by means of the flight director. Different methods for calculating the recovery signal, one based on fast model predictive control and another using an energy based approach, have been evaluated in four relevant operational scenarios by experienced commercial as well as test pilots in the Vertical Motion Simulator at NASA Ames Research Center. Evaluation results show that this approach could be able to assist the pilots in executing a correct stall recovery maneuver.

  17. The zonal tidal effect on the variation in the rotation rate of the Earth with a fluid core II. Numerical calculation and comparisons

    Science.gov (United States)

    Zhang, Han-Wei; Zheng, Yong; Du, Lan; Pan, Guan-Song

    The tidal variation in Earth rotation rate is a periodical response to solar-lunar tide generating potential (TGP). Some theoretical formulae are given here based on Doodson development of TGP including the variations in Earth rotation rate, LOD and UT1. Finally the zonal tidal effect on the variation in the fluid core Earth rotation rate is calculated according to the formula deduced by Xi Qinwen (1995). The calculation shows that the results in this paper are well consistent with the ones in IERS (96), which indicates the correctness of the theoretical formula we deduced. It is also shown that the effects from the high frequency parts are relatively small, within the observing precision so far; relatively large effects due to the lower parts, which should be able to be seperated from the observed data, are actually difficult to make because of the influence from some non-tidal factors as well as short time span data.

  18. Modeling the cosmic-ray-induced soft-error rate in integrated circuits: An overview

    International Nuclear Information System (INIS)

    Srinivasan, G.R.

    1996-01-01

    This paper is an overview of the concepts and methodologies used to predict soft-error rates (SER) due to cosmic and high-energy particle radiation in integrated circuit chips. The paper emphasizes the need for the SER simulation using the actual chip circuit model which includes device, process, and technology parameters as opposed to using either the discrete device simulation or generic circuit simulation that is commonly employed in SER modeling. Concepts such as funneling, event-by-event simulation, nuclear history files, critical charge, and charge sharing are examined. Also discussed are the relative importance of elastic and inelastic nuclear collisions, rare event statistics, and device vs. circuit simulations. The semi-empirical methodologies used in the aerospace community to arrive at SERs [also referred to as single-event upset (SEU) rates] in integrated circuit chips are reviewed. This paper is one of four in this special issue relating to SER modeling. Together, they provide a comprehensive account of this modeling effort, which has resulted in a unique modeling tool called the Soft-Error Monte Carlo Model, or SEMM

  19. CRSEC: a general purpose Hauser--Feshbach code for the calculation of nuclear cross-sections and thermonuclear reaction rates

    International Nuclear Information System (INIS)

    Woosley, S.; Fowler, W.A.

    1977-09-01

    CRSEC is a FORTRAN IV computer code designed for the efficient calculation of average nuclear cross sections in situations where a statistical theory of nuclear reactions is applicable and where compound nuclear formation is the dominant reaction mechanism. This code generates cross sections of roughly factor of 2 accuracy for incident particle energies in the range of 10 keV to 10 MeV for most target nuclei from magnesium to bismuth. Exceptions usually involve reactions that enter the compound nucleus at such a low energy that fewer than 10 levels are present in the ''energy window of interest.'' The incident particle must be a neutron, proton, or alpha particle, and only binary reactions resulting in the emission of a single n, p, α, or γ (cascade) are calculated. CRSEC is quite fast, a complete calculation of 12 different reactions over a grid of roughly 150 energy points and the generation of Maxwellian averaged rates taking about 30 seconds of CDC7600 time. Also the semi-empirical parameterization of nuclear properties contained in CRSEC is very general. Greater accuracy may be obtained, however, by furnishing specific low-lying excited states, level density parameterization, and nuclear strength functions. A more general version of CRSEC, called CRSECI, is available that conserves isospin properly in all reactions and allows the user to specify a given degree of isospin mixing in the highly excited states of the compound nucleus. Besides the cross section as a function of center-of-mass energy, CRSEC also generates the Maxwell--Boltzmann averaged thermonuclear reaction rate and temperature dependent nuclear partition function for a grid of temperatures from 10 8 to 10 10 0 K. Sections of this report describe in greater detail the physics employed in CRSEC and how to use the code. 2 tables

  20. Calculation of the quantities of radiation risk in Japanese population

    International Nuclear Information System (INIS)

    Nakamura, Yuji

    1993-01-01

    The purpose of this study was to reevaluate various kinds of indicators of radiation risks using additive projection and multiplicative projection models, as proposed by ICRP. Total death probability rate (1985) and probability rate of cancer death (1983 to 1987) were used as data base. The following indicators were calculated: total conditional death probability rate and conditional death probability rate; normalized death age probability density and unconditional death probability rate; attributable life-time probability of cancer death; and other risk indicators, including mean loss of life expectancy, reduction of life expectancy, mean annually committed probability of attributable cancer deaths, annual extra probability of cancer death, probability density of the age of death, maximum relative death probability rate (age at maximum relative rate), and probabilistic aging. In terms of calculations of these risk indicators for the comprehensive cancer death, there was no great difference between the Japanese population and ICRP. When calculating according to sites of cancer, calculations of indicators for cancer mortality (or cancer cure rate) in the Japanese population might bedifferent from ICRP's calculation. (N.K.) different from ICRP's calculations. (N.K.)

  1. 'Prostate Cancer Risk Calculator' mobile applications (Apps): a systematic review and scoring using the validated user version of the Mobile Application Rating Scale (uMARS).

    Science.gov (United States)

    Adam, Ahmed; Hellig, Julian C; Perera, Marlon; Bolton, Damien; Lawrentschuk, Nathan

    2018-04-01

    The use of mobile phone applications (Apps) has modernised the conventional practice of medicine. The diagnostic ability of the current Apps in prostate specific antigen monitoring, and its diagnostic ability within prostate cancer (PCa) risk calculators have not yet been appraised. We aimed to review, rate and assess the everyday functionality, and utility of all the currently available PCa risk calculator Apps. A systematic search on iTunes, Google Play Store, Blackberry World and Windows Apps Store, was performed on 23/11/2017, using the search term 'prostate cancer risk calculator'. After applying the exclusion criteria, each App was individually assessed and rated using pre-set criteria and grading was performed using the validated uMARS scale. In total, 83 Apps were retrieved. After applying our exclusion criteria, only 9 Apps were relevant, with 2 duplicated, and the remaining 7 were suitable for critical review. Data sizes ranged from 414 kb to 10.1 Mb. The cost of the Apps ranged from South African rand (ZAR) 0.00 to ZAR 29.99. The overall mean category uMARS scores ranged from 2.8/5 to 4.5/5. Apps such as Rotterdam Prostate Cancer Risk Calculator, Coral-Prostate Cancer Nomogram Calculator and CPC Risk Calculator, performed the best. The current PCa risk calculator mobile Apps available may be beneficial in counselling the concerned at risk patient. These Apps have potential to assist both the patient and the urologist alike. The PCa risk calculator App 'predictability' may be further enhanced by the incorporation of newly validated risk factors and predictors for PCa.

  2. The Neighboring Column Approximation (NCA) – A fast approach for the calculation of 3D thermal heating rates in cloud resolving models

    International Nuclear Information System (INIS)

    Klinger, Carolin; Mayer, Bernhard

    2016-01-01

    Due to computational costs, radiation is usually neglected or solved in plane parallel 1D approximation in today's numerical weather forecast and cloud resolving models. We present a fast and accurate method to calculate 3D heating and cooling rates in the thermal spectral range that can be used in cloud resolving models. The parameterization considers net fluxes across horizontal box boundaries in addition to the top and bottom boundaries. Since the largest heating and cooling rates occur inside the cloud, close to the cloud edge, the method needs in first approximation only the information if a grid box is at the edge of a cloud or not. Therefore, in order to calculate the heating or cooling rates of a specific grid box, only the directly neighboring columns are used. Our so-called Neighboring Column Approximation (NCA) is an analytical consideration of cloud side effects which can be considered a convolution of a 1D radiative transfer result with a kernel or radius of 1 grid-box (5 pt stencil) and which does usually not break the parallelization of a cloud resolving model. The NCA can be easily applied to any cloud resolving model that includes a 1D radiation scheme. Due to the neglect of horizontal transport of radiation further away than one model column, the NCA works best for model resolutions of about 100 m or lager. In this paper we describe the method and show a set of applications of LES cloud field snap shots. Correction terms, gains and restrictions of the NCA are described. Comprehensive comparisons to the 3D Monte Carlo Model MYSTIC and a 1D solution are shown. In realistic cloud fields, the full 3D simulation with MYSTIC shows cooling rates up to −150 K/d (100 m resolution) while the 1D solution shows maximum coolings of only −100 K/d. The NCA is capable of reproducing the larger 3D cooling rates. The spatial distribution of the heating and cooling is improved considerably. Computational costs are only a factor of 1.5–2 higher compared to a 1D

  3. Relativistic many-body calculation of energies, transition rates, lifetimes, and multipole polarizabilities in Cs-like La iii

    Science.gov (United States)

    Safronova, U. I.; Safronova, M. S.

    2014-05-01

    Excitation energies of the [Xe]nd (n =5-9), [Xe]ns (n =6-10), [Xe]np (n =6-9), [Xe]nf (n =4-8), and [Xe]ng (n =5-8) states in La iii, where [Xe] = 1s22s22p63s23p63d104s24p64d105s25p6, are evaluated. Electric dipole matrix elements for the allowed transitions between the low-lying [Xe]nd, [Xe]ns, [Xe]np, [Xe]nf, and [Xe]ng states in the La iii ion are calculated using the high-precision relativistic all-order method where all single, double, and partial triple excitations of the Dirac-Fock wave functions are included to all orders of perturbation theory. Recommended values are provided for a large number of electric dipole matrix elements, oscillator strengths, transition rates, and lifetimes. Scalar and tensor polarizabilities of the states listed above are evaluated. The uncertainties of the recommended values are estimated. Electric quadrupole and magnetic dipole matrix elements are calculated to determine lifetimes of the 5d5/2 and 6s metastable levels. The ground-state E1, E2, and E3 static polarizabilities are calculated. This work provides recommended values critically evaluated for their accuracy for a number of La iii atomic properties for use in planning and analysis of various experiments as well as theoretical modeling.

  4. Eight-dimensional quantum reaction rate calculations for the H+CH4 and H2+CH3 reactions on recent potential energy surfaces.

    Science.gov (United States)

    Zhou, Yong; Zhang, Dong H

    2014-11-21

    Eight-dimensional (8D) transition-state wave packet simulations have been performed on two latest potential energy surfaces (PES), the Zhou-Fu-Wang-Collins-Zhang (ZFWCZ) PES [Y. Zhou, B. Fu, C. Wang, M. A. Collins, and D. H. Zhang, J. Chem. Phys. 134, 064323 (2011)] and the Xu-Chen-Zhang (XCZ)-neural networks (NN) PES [X. Xu, J. Chen, and D. H. Zhang, Chin. J. Chem. Phys. 27, 373 (2014)]. Reaction rate constants for both the H+CH4 reaction and the H2+CH3 reaction are calculated. Simulations of the H+CH4 reaction based on the XCZ-NN PES show that the ZFWCZ PES predicts rate constants with reasonable high accuracy for low temperatures while leads to slightly lower results for high temperatures, in line with the distribution of interpolation error associated with the ZFWCZ PES. The 8D H+CH4 rate constants derived on the ZFWCZ PES compare well with full-dimensional 12D results based on the equivalent m-ZFWCZ PES, with a maximum relative difference of no more than 20%. Additionally, very good agreement is shown by comparing the 8D XCZ-NN rate constants with the 12D results obtained on the ZFWCZ-WM PES, after considering the difference in static barrier height between these two PESs. The reaction rate constants calculated for the H2+CH3 reaction are found to be in good consistency with experimental observations.

  5. High-precision QED calculations of the hyperfine structure in hydrogen and transition rates in multicharged ions

    Energy Technology Data Exchange (ETDEWEB)

    Volotka, A.V.

    2006-07-01

    Studies of the hyperfine splitting in hydrogen are strongly motivated by the level of accuracy achieved in recent atomic physics experiments, which yield finally model-independent informations about nuclear structure parameters with utmost precision. Considering the current status of the determination of corrections to the hyperfine splitting of the ground state in hydrogen, this thesis provides further improved calculations by taking into account the most recent value for the proton charge radius. Comparing theoretical and experimental data of the hyperfine splitting in hydrogen the proton-size contribution is extracted and a relativistic formula for this contribution is derived in terms of moments of the nuclear charge and magnetization distributions. An iterative scheme for the determination of the Zemach and magnetic radii of the proton is proposed. As a result, the Zemach and magnetic radii are determined and the values are compared with the corresponding ones deduced from data obtained in electron-proton scattering experiments. The extraction of the Zemach radius from a rescaled difference between the hyperfine splitting in hydrogen and in muonium is considered as well. Investigations of forbidden radiative transitions in few-electron ions within ab initio QED provide a most sensitive tool for probing the influence of relativistic electron-correlation and QED corrections to the transition rates. Accordingly, a major part of this thesis is devoted to detailed studies of radiative and interelectronic-interaction effects to the transition probabilities. The renormalized expressions for the corresponding corrections in one- and twoelectron ions as well as for ions with one electron over closed shells are derived employing the two-time Green's function method. Numerical results for the correlation corrections to magnetic transition rates in He-like ions are presented. For the first time also the frequency-dependent contribution is calculated, which has to be

  6. High-precision QED calculations of the hyperfine structure in hydrogen and transition rates in multicharged ions

    International Nuclear Information System (INIS)

    Volotka, A.V.

    2006-01-01

    Studies of the hyperfine splitting in hydrogen are strongly motivated by the level of accuracy achieved in recent atomic physics experiments, which yield finally model-independent informations about nuclear structure parameters with utmost precision. Considering the current status of the determination of corrections to the hyperfine splitting of the ground state in hydrogen, this thesis provides further improved calculations by taking into account the most recent value for the proton charge radius. Comparing theoretical and experimental data of the hyperfine splitting in hydrogen the proton-size contribution is extracted and a relativistic formula for this contribution is derived in terms of moments of the nuclear charge and magnetization distributions. An iterative scheme for the determination of the Zemach and magnetic radii of the proton is proposed. As a result, the Zemach and magnetic radii are determined and the values are compared with the corresponding ones deduced from data obtained in electron-proton scattering experiments. The extraction of the Zemach radius from a rescaled difference between the hyperfine splitting in hydrogen and in muonium is considered as well. Investigations of forbidden radiative transitions in few-electron ions within ab initio QED provide a most sensitive tool for probing the influence of relativistic electron-correlation and QED corrections to the transition rates. Accordingly, a major part of this thesis is devoted to detailed studies of radiative and interelectronic-interaction effects to the transition probabilities. The renormalized expressions for the corresponding corrections in one- and twoelectron ions as well as for ions with one electron over closed shells are derived employing the two-time Green's function method. Numerical results for the correlation corrections to magnetic transition rates in He-like ions are presented. For the first time also the frequency-dependent contribution is calculated, which has to be

  7. Fe IX CALCULATIONS FOR THE SOLAR DYNAMICS OBSERVATORY

    International Nuclear Information System (INIS)

    Foster, Adam R.; Testa, Paola

    2011-01-01

    New calculations of the energy levels, radiative transition rates, and collisional excitation rates of Fe IX have been carried out using the Flexible Atomic Code, paying close attention to experimentally identified levels and extending existing calculations to higher energy levels. For lower levels, R-matrix collisional excitation rates from earlier work have been used. Significant emission is predicted by these calculations in the 5f-3d transitions, which will impact analysis of Solar Dynamics Observatory Atmospheric Imaging Assembly observations using the 94 A filter.

  8. Parameters calculation of shielding experiment

    International Nuclear Information System (INIS)

    Gavazza, S.

    1986-02-01

    The radiation transport methodology comparing the calculated reactions and dose rates for neutrons and gama-rays, with experimental measurements obtained on iron shield, irradiated in the YAYOI reactor is evaluated. The ENDF/B-IV and VITAMIN-C libraries and the AMPX-II modular system, for cross sections generation collapsed by the ANISN code were used. The transport calculations were made using the DOT 3.5 code, adjusting the boundary iron shield source spectrum to the reactions and dose rates, measured at the beginning of shield. The neutron and gamma ray distributions calculated on the iron shield presented reasonable agreement with experimental measurements. An experimental arrangement using the IEA-R1 reactor to determine a shielding benchmark is proposed. (Author) [pt

  9. Calculations of the Auger deexcitation rate of the dtμ within the muonic quasi-molecule, [(dtμ)dee

    International Nuclear Information System (INIS)

    Armour, E.A.G.; Lewis, D.M.; Hara, S.

    1993-01-01

    A key process in muon catalysed fusion is the deexcitation of the dtμ within the resonant muonic quasi-molecule [(dtμ)dee], by emission of an Auger electron. The dtμ in the quasi-molecule is initially in a weakly bound excited state with J = 1 and v = 1. In this paper, calculations taking full account of the molecular nature of the quasi-molecule are carried out of the rate of the dominant deexcitation to the state with J = 0 and v = 1. (orig.)

  10. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, Omar, E-mail: omar.chibani@fccc.edu; C-M Ma, Charlie [Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  11. Calculations of fission rate distribution in the core of WWER-1000 mock-up on the LR-0 reactor using alternative methods and comparison with results of measurements

    International Nuclear Information System (INIS)

    Zaritskiy, S.; Kovalishin, A.; Tsvetkov, T.; Rypar, V.; Svadlenkova, M.

    2011-01-01

    General review of experimental and calculation researches on WWER-440 and WWER-1000 mock-ups on the reactor LR-0 was introduced on the twentieth Symposium AER. The experimental core fission rate distribution was obtained by means of gamma-scanning of the fuel pins - 140La single peak (1596 keV) measurements and wide energy range (approximately 600-900 keV) measurements. Altogether from 260 to 500 fuel pins were scanned in different experiments. The measurements were arranged in the middle of the fuel (the active part of pin). Pin-to-pin calculations of the WWER-1000 mock-up core fission rate distribution were performed with several codes: Monte Carlo codes MCU-REA/2 and MCNPX with different nuclear data libraries, diffusion code RADAR (63 energy groups library) and code SVL based on Surface Harmonics Method (69 energy groups). Calculated data are compared with experimental ones. The obtained results allow developing the benchmark for core calculations methodologies, evaluating and validating source reliability for the out-of-core (inside and outside pressure vessel) neutron transport calculations. (Authors)

  12. Exogenous HIV-1 Nef upsets the IFN-γ-induced impairment of human intestinal epithelial integrity.

    Directory of Open Access Journals (Sweden)

    Maria Giovanna Quaranta

    Full Text Available The mucosal tissues play a central role in the transmission of HIV-1 infection as well as in the pathogenesis of AIDS. Despite several clinical studies reported intestinal dysfunction during HIV infection, the mechanisms underlying HIV-induced impairments of mucosal epithelial barrier are still unclear. It has been postulated that HIV-1 alters enterocytic function and HIV-1 proteins have been detected in several cell types of the intestinal mucosa. In the present study, we analyzed the effect of the accessory HIV-1 Nef protein on human epithelial cell line.We used unstimulated or IFN-γ-stimulated Caco-2 cells, as a model for homeostatic and inflamed gastrointestinal tracts, respectively. We investigated the effect of exogenous recombinant Nef on monolayer integrity analyzing its uptake, transepithelial electrical resistance, permeability to FITC-dextran and the expression of tight junction proteins. Moreover, we measured the induction of proinflammatory mediators. Exogenous Nef was taken up by Caco-2 cells, increased intestinal epithelial permeability and upset the IFN-γ-induced reduction of transepithelial resistance, interfering with tight junction protein expression. Moreover, Nef inhibited IFN-γ-induced apoptosis and up-regulated TNF-α, IL-6 and MIP-3α production by Caco-2 cells while down-regulated IL-10 production. The simultaneous exposure of Caco-2 cells to Nef and IFN-γ did not affect cytokine secretion respect to untreated cells. Finally, we found that Nef counteracted the IFN-γ induced arachidonic acid cascade.Our findings suggest that exogenous Nef, perturbing the IFN-γ-induced impairment of intestinal epithelial cells, could prolong cell survival, thus allowing for accumulation of viral particles. Our results may improve the understanding of AIDS pathogenesis, supporting the discovery of new therapeutic interventions.

  13. Effects Influencing Plutonium-Absorber Interactions and Distributions in Routine and Upset Waste Treatment Plant Operations

    Energy Technology Data Exchange (ETDEWEB)

    Delegard, Calvin H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sinkov, Sergey I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fiskum, Sandra K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-05-01

    This report is the third in a series of analyses written in support of a plan to revise the Hanford Waste Treatment and Immobilization Plant (WTP) Preliminary Criticality Safety Evaluation Report (CSER) that is being implemented at the request of the U.S. Department of Energy (DOE) Criticality Safety Group. A report on the chemical disposition of plutonium in Hanford tank wastes was prepared as Phase 1 of this plan (Delegard and Jones 2015). Phase 2 is the provision of a chemistry report to describe the potential impacts on criticality safety of waste processing operations within the WTP (Freer 2014). In accordance with the request from the Environmental and Nuclear Safety Department of the WTP (Miles and Losey 2012), the Phase 2 report assessed the potential for WTP process conditions within and outside the range of normal control parameters to change the ratio of fissile material to neutron-absorbing material in the waste as it is processed with an eye towards potential implications for criticality safety. The Phase 2 study also considered the implications should WTP processes take place within the credible range of chemistry upset conditions. In the present Phase 3 report, the 28 phenomena described in the Phase 2 report were considered with respect to the disposition of plutonium and various absorber elements. The phenomena identified in the Phase 2 report are evaluated in light of the Phase 1 report and other resources to determine the impacts these phenomena might have to alter the plutonium/absorber dispositions and ratios. The outcomes of the Phase 3 evaluations then can be used to inform subsequent engineering decisions and provide reasonable paths forward to mitigate or overcome real or potential criticality concern in plant operations.

  14. A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

    Energy Technology Data Exchange (ETDEWEB)

    Ballester, Facundo, E-mail: Facundo.Ballester@uv.es [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Carlsson Tedgren, Åsa [Department of Medical and Health Sciences (IMH), Radiation Physics, Faculty of Health Sciences, Linköping University, Linköping SE-581 85, Sweden and Department of Medical Physics, Karolinska University Hospital, Stockholm SE-171 76 (Sweden); Granero, Domingo [Department of Radiation Physics, ERESA, Hospital General Universitario, Valencia E-46014 (Spain); Haworth, Annette [Department of Physical Sciences, Peter MacCallum Cancer Centre and Royal Melbourne Institute of Technology, Melbourne, Victoria 3000 (Australia); Mourtada, Firas [Department of Radiation Oncology, Helen F. Graham Cancer Center, Christiana Care Health System, Newark, Delaware 19713 (United States); Fonseca, Gabriel Paiva [Instituto de Pesquisas Energéticas e Nucleares – IPEN-CNEN/SP, São Paulo 05508-000, Brazil and Department of Radiation Oncology (MAASTRO), GROW, School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Zourari, Kyveli; Papagiannis, Panagiotis [Medical Physics Laboratory, Medical School, University of Athens, 75 MikrasAsias, Athens 115 27 (Greece); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Siebert, Frank-André [Clinic of Radiotherapy, University Hospital of Schleswig-Holstein, Campus Kiel, Kiel 24105 (Germany); Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); and others

    2015-06-15

    Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by

  15. Increasing the competitiveness of maintenance contract rates by using an alternative methodology for the calculation of average vehicle maintenance costs

    Directory of Open Access Journals (Sweden)

    Stephen Carstens

    2008-11-01

    Full Text Available Companies tend to outsource transport to fleet management companies to increase efficiencies if transport is a non-core activity. The provision of fleet management services on contract introduces a certain amount of financial risk to the fleet management company, specifically fixed rate maintenance contracts. The quoted rate needs to be sufficient and also competitive in the market. Currently the quoted maintenance rates are based on the maintenance specifications of the manufacturer and the risk management approach of the fleet management company. This is usually reflected in a contingency that is included in the quoted maintenance rate. An alternative methodology for calculating the average maintenance cost for a vehicle fleet is proposed based on the actual maintenance expenditures of the vehicles and accepted statistical techniques. The proposed methodology results in accurate estimates (and associated confidence limits of the true average maintenance cost and can beused as a basis for the maintenance quote.

  16. SEU ground and flight data in static random access memories

    International Nuclear Information System (INIS)

    Liu, J.; Duan, J.L.; Hou, M.D.; Sun, Y.M.; Yao, H.J.; Mo, D.; Zhang, Q.X.; Wang, Z.G.; Jin, Y.F.; Cai, J.R.; Ye, Z.H.; Han, J.W.; Lin, Y.L.; Huang, Z.

    2006-01-01

    This paper presents the vulnerabilities of single event effects (SEEs) simulated by heavy ions on ground and observed on SJ-5 research satellite in space for static random access memories (SRAMs). A single event upset (SEU) prediction code has been used to estimate the proton-induced upset rates based on the ground test curve of SEU cross-section versus heavy ion linear energy transfer (LET). The result agrees with that of the flight data

  17. Gaseous Nitrogen Orifice Mass Flow Calculator

    Science.gov (United States)

    Ritrivi, Charles

    2013-01-01

    The Gaseous Nitrogen (GN2) Orifice Mass Flow Calculator was used to determine Space Shuttle Orbiter Water Spray Boiler (WSB) GN2 high-pressure tank source depletion rates for various leak scenarios, and the ability of the GN2 consumables to support cooling of Auxiliary Power Unit (APU) lubrication during entry. The data was used to support flight rationale concerning loss of an orbiter APU/hydraulic system and mission work-arounds. The GN2 mass flow-rate calculator standardizes a method for rapid assessment of GN2 mass flow through various orifice sizes for various discharge coefficients, delta pressures, and temperatures. The calculator utilizes a 0.9-lb (0.4 kg) GN2 source regulated to 40 psia (.276 kPa). These parameters correspond to the Space Shuttle WSB GN2 Source and Water Tank Bellows, but can be changed in the spreadsheet to accommodate any system parameters. The calculator can be used to analyze a leak source, leak rate, gas consumables depletion time, and puncture diameter that simulates the measured GN2 system pressure drop.

  18. Results of calculations of external gamma radiation exposure rates from local fallout and the related radionuclide compositions of two hypothetical 1-MT nuclear bursts. Final report

    International Nuclear Information System (INIS)

    Hicks, H.

    1984-12-01

    This report presents data on calculated gamma radiation exposure rates and local surface deposition of related radionuclides resulting from two hypothetical 1-Mt nuclear bursts. Calculations are made of the debris from two types of bombs: one containing 235 U as a fissionable material (designated oralloy), the other containing 238 U (designated tuballoy). 4 references

  19. GTHTR 300 economic calculation with Mini G4ECONS as a basis for generation cost of GTHTR 10 MWe calculation

    International Nuclear Information System (INIS)

    Mochamad Nasrullah; Nurlaila

    2014-01-01

    The government plan to build Experimental Power Reactor (EPR) requires measurable economic assessment. The purpose of the study was to recalculate Gas Turbine High Temperature Reactor of 300 MWe (GTHTR 300) and compare the results with reference data. Then calculate generation cost of GTHTR 3, 5 and 10 MWe using the scale factor calculation. The methodology used is covered the generation cost calculation using the Mini G4Econs spread sheet models published by IAEA. Result of the verification calculation showed that a relatively similar, which means that the calculation model could be used to calculate for same other cases. Afterward, using scale factor, smaller scale reactor could be calculated. The calculation result show that electricity generation cost of SMR-HTR type with load factor 90% and discount rate 10% for power capacity 3, 5 and 10 MWe are 29.5, 22.68 and 16.17 cents$/kWh respectively. However, because the EPR is planning to be built as a non-commercial power reactors, then 5 % and 3 % of discount rate could be chosen, each of those discount rate will result electricity generation cost of 10.37 cents$/kWh and 8.56 cents$/kWh respectively. These result could be considered by the government for developing SMR type of HTR. (author)

  20. Gamma dose rate calculations for conceptual design of a shield system for spent fuel interim dry storage in CNA 1

    International Nuclear Information System (INIS)

    Blanco, A; Gomez S

    2012-01-01

    After completing the rearrangement of the Spent Fuel Elements (SFE) into a compact arrangement in the two storage water pools, Atucha Nuclear Reactor 1 (ANR 1) will leave free position for the wet storage of the SFE discharged until December 2014. Even, in two possible scenarios, such as extending operation from 2015 or the cessation of operation after that date, it will be necessary to empty the interim storage water pools transferring the SFE to a temporary dry storage system. Because the law 25.018 'Management of Radioactive Wastes' implies for the first scenario - operation beyond 2015 - that Nucleoelectrica Argentina S.A. will still be in charge of the dry storage system and for the second - the cessation of operation after 2015 - the National Commission of Atomic Energy (CNEA) will be in charge by the National Management Program of Radioactive Wastes, the interim dry storage system of SNF is an issue of common interest which justifies go forward together. For that purpose and in accordance with the criticality and shielding calculations relevant to the project, in this paper we present the dose rate calculations for shielding conceptual design of a system for dry interim storage of the SFE of ANR 1. The specifications includes that the designed system must be suitable without modification for the SFE of the ANR 2. The results for the calculation of the photon dose rate, in touch and at one meter far, for the Transport Module and the Container of the SFE, are presented, which are required and controlled by the National Regulatory Authority (NRA) and the International Atomic Energy Agency (IAEA). It was used the SAS4 module of SCALE5.1 system and MCNP5. As a design tool for the photon shielding in order to meet current standards for allowable dose rates, a radial and axial parametric analysis were developed based on the thickness of lead of the Transport Module. The results were compared and verified between the two computing systems. Before this

  1. Fulltext PDF

    Indian Academy of Sciences (India)

    PRAKASH KUMAR

    often this comes about because the work of perturbation raises the object's ... be stationary, any perturbation will upset the balance and produce ...... While economical, though, the same cost-benefit calculation ..... Gravity and life on the ground ...

  2. Observed Barium Emission Rates

    Science.gov (United States)

    Stenbaek-Nielsen, H. C.; Wescott, E. M.; Hallinan, T. J.

    1993-01-01

    The barium releases from the CRRES satellite have provided an opportunity for verifying theoretically calculated barium ion and neutral emission rates. Spectra of the five Caribbean releases in the summer of 1991 were taken with a spectrograph on board a U.S. Air Force jet aircraft. Because the line of sight release densities are not known, only relative rates could be obtained. The observed relative rates agree well with the theoretically calculated rates and, together with other observations, confirm the earlier detailed theoretical emission rates. The calculated emission rates can thus with good accuracy be used with photometric observations. It has been postulated that charge exchange between neutral barium and oxygen ions represents a significant source for ionization. If so. it should be associated with emissions at 4957.15 A and 5013.00 A, but these emissions were not detected.

  3. Time averaging procedure for calculating the mass and energy transfer rates in adiabatic two phase flow

    International Nuclear Information System (INIS)

    Boccaccini, L.V.

    1986-07-01

    To take advantages of the semi-implicit computer models - to solve the two phase flow differential system - a proper averaging procedure is also needed for the source terms. In fact, in some cases, the correlations normally used for the source terms - not time averaged - fail using the theoretical time step that arises from the linear stability analysis used on the right handside. Such a time averaging procedure is developed with reference to the bubbly flow regime. Moreover, the concept of mass that must be exchanged to reach equilibrium from a non-equilibrium state is introduced to limit the mass transfer during a time step. Finally some practical calculations are performed to compare the different correlations for the average mass transfer rate developed in this work. (orig.) [de

  4. Development of calculation system for decontamination effect, CDE

    International Nuclear Information System (INIS)

    Satoh, Daiki; Kojima, Kensuke; Oizumi, Akito; Matsuda, Norihiro; Kugo, Teruhiko; Sakamoto, Yukio; Endo, Akira; Okajima, Shigeaki

    2012-08-01

    Large amount of radionuclides had been discharged to environment in the accident of the Tokyo Electric Power Company Fukushima Daiichi Nuclear Power Plant caused by the 2011 off the Pacific coast of Tohoku Earthquake. The radionuclides deposited on the ground elevate dose rates in large area around the Fukushima site. For the reduction of the dose rate and recovery of the environment, decontamination based on a rational plan is an important and urgent subject. A computer software, named CDE (Calculation system for Decontamination Effect), has been developed to support planning the decontamination. CDE calculates the dose rates before the decontamination by using a database of dose contributions by radioactive cesium. The decontamination factor is utilized in the prediction of the dose rates after the decontamination, and dose rate reduction factor is evaluated to express the decontamination effect. The results are visualized on the image of a target zone with color map. In this paper, the overview of the software and the dose calculation method are reported. The comparison with the calculation results by a three-dimensional radiation transport code PHITS is also presented. In addition, the source code of the dose calculation program and user's manual of CDE are attached as appendices. (author)

  5. Radiation dose distributions due to sudden ejection of cobalt device

    International Nuclear Information System (INIS)

    Abdelhady, Amr

    2016-01-01

    The evaluation of the radiation dose during accident in a nuclear reactor is of great concern from the viewpoint of safety. One of important accident must be analyzed and may be occurred in open pool type reactor is the rejection of cobalt device. The study is evaluating the dose rate levels resulting from upset withdrawal of co device especially the radiation dose received by the operator in the control room. Study of indirect radiation exposure to the environment due to skyshine effect is also taken into consideration in order to evaluate the radiation dose levels around the reactor during the ejection trip. Microshield, SHLDUTIL, and MCSky codes were used in this study to calculate the radiation dose profiles during cobalt device ejection trip inside and outside the reactor building. - Highlights: • This study aims to calculate the dose rate profiles after cobalt device ejection from open-pool-type reactor core. • MicroShield code was used to evaluate the dose rates inside the reactor control room. • McSKY code was used to evaluate the dose rates outside the reactor building. • The calculated dose rates for workers are higher than the permissible limits after 18 s from device ejection.

  6. Program for TI programmable 59 calculator for calculation of 3H concentration of water samples

    International Nuclear Information System (INIS)

    Hussain, S.D.; Asghar, G.

    1982-09-01

    A program has been developed for TI Programmable 59 Calculator of Texas Instruments Inc. to calculate from the observed parameters such as count rate etc. the 3 H (tritium) concentration of water samples processed with/without prior electrolytic enrichment. Procedure to use the program has been described in detail. A brief description of the laboratory treatment of samples and the mathematical equations used in the calculations have been given. (orig./A.B.)

  7. Cooling tower calculations

    International Nuclear Information System (INIS)

    Simonkova, J.

    1988-01-01

    The problems are summed up of the dynamic calculation of cooling towers with forced and natural air draft. The quantities and relations are given characterizing the simultaneous exchange of momentum, heat and mass in evaporative water cooling by atmospheric air in the packings of cooling towers. The method of solution is clarified in the calculation of evaporation criteria and thermal characteristics of countercurrent and cross current cooling systems. The procedure is demonstrated of the calculation of cooling towers, and correction curves and the effect assessed of the operating mode at constant air number or constant outlet air volume flow on their course in ventilator cooling towers. In cooling towers with the natural air draft the flow unevenness is assessed of water and air relative to its effect on the resulting cooling efficiency of the towers. The calculation is demonstrated of thermal and resistance response curves and cooling curves of hydraulically unevenly loaded towers owing to the water flow rate parameter graded radially by 20% along the cross-section of the packing. Flow rate unevenness of air due to wind impact on the outlet air flow from the tower significantly affects the temperatures of cooled water in natural air draft cooling towers of a design with lower demands on aerodynamics, as early as at wind velocity of 2 m.s -1 as was demonstrated on a concrete example. (author). 11 figs., 10 refs

  8. The Atmospherically Important Reaction of Hydroxyl Radicals with Methyl Nitrate: A Theoretical Study Involving the Calculation of Reaction Mechanisms, Enthalpies, Activation Energies, and Rate Coefficients.

    Science.gov (United States)

    Ng, Maggie; Mok, Daniel K W; Lee, Edmond P F; Dyke, John M

    2017-09-07

    A theoretical study, involving the calculation of reaction enthalpies, activation energies, mechanisms, and rate coefficients, was made of the reaction of hydroxyl radicals with methyl nitrate, an important process for methyl nitrate removal in the earth's atmosphere. Four reaction channels were considered: formation of H 2 O + CH 2 ONO 2 , CH 3 OOH + NO 2 , CH 3 OH + NO 3 , and CH 3 O + HNO 3 . For all channels, geometry optimization and frequency calculations were performed at the M06-2X/6-31+G** level, while relative energies were improved at the UCCSD(T*)-F12/CBS level. The major channel is found to be the H abstraction channel, to give the products H 2 O + CH 2 ONO 2 . The reaction enthalpy (ΔH 298 K RX ) of this channel is computed as -17.90 kcal mol -1 . Although the other reaction channels are also exothermic, their reaction barriers are high (>24 kcal mol -1 ), and therefore these reactions do not contribute to the overall rate coefficient in the temperature range considered (200-400 K). Pathways via three transition states were identified for the H abstraction channel. Rate coefficients were calculated for these pathways at various levels of variational transition state theory including tunneling. The results obtained are used to distinguish between two sets of experimental rate coefficients, measured in the temperature range of 200-400 K, one of which is approximately an order of magnitude greater than the other. This comparison, as well as the temperature dependence of the computed rate coefficients, shows that the lower experimental values are favored. The implications of the results to atmospheric chemistry are discussed.

  9. Measuring the absolute disintegration rate of a radioactive gas with a moveable endplate discharge counter (MEP) and theoretical calculation of wall effect

    International Nuclear Information System (INIS)

    Jaffey, A.H.; Gray, J.; Bentley, W.C.; Lerner, J.L.

    1987-09-01

    A precision built moveable endplate Geiger-Mueller counter was used to measure the absolute disintegration rate of a beta-emitting radioactive gas. A Geiger-Mueller counter used for measuring gaseous radioactivity has 85 Kr (beta energy, 0.67 MeV). The wall effect calculation is readily extendable to other beta energies

  10. Study of the post-equilibrium slope approximation in the calculation of glomerular filtration rate using the 51Cr-EDTA single injection technique

    International Nuclear Information System (INIS)

    Nimmon, C.C.; McAlister, J.M.; Hickson, B.; Cattell, W.R.

    1975-01-01

    A comparison of methods for calculating the renal clearance of EDTA from the plasma disappearance curve, after a single injection, has been made. Measurements were made on 38 patients, using external monitoring and venous blood sampling techniques, over a period of 24 h after an injection of 100 μCi of 51 Cr-EDTA. The results indicate that the period 3 - 6 h after injection is suitable for sampling the post-equilibrium part of the plasma disappearance curve for values of the glomerular filtration rate (GFR) in the range 0 - 140 ml/min. It was also found that, to within the individual measurement errors, the values of the clearance calculated by using the post-equilibrium period only (PES clearance) can be considered to show a constant proportionality to the values calculated by using the entire plasma disappearance curve (total clearance). (author)

  11. Biostatistics with emphasis on life table survival rate calculations (including Kaplan Meier) and the logrank test

    International Nuclear Information System (INIS)

    Mould, Richard F.

    1995-01-01

    Purpose/Objective: To explain some of the most useful statistical calculation procedures which are relevant to radiation oncologists and to provide insights on what tests and procedures should be used in various situations such as when survival rates and their associated standard errors have to be determined. To describe some of the problems and pitfalls in clinical trial designs which have to be overcome if a trial is to have the possibility of reaching a successful conclusion. To review methods of computing criteria to quantitatively describe criteria of success (eg. quality of life, long-term survival, cure) of radiation oncology and to suggest possible future statistical improvements in this area. Chi-Squared Test: The chi-squared test is probably the most useful of the tests of statistical significance for the radiation oncologist. Applications will be described, including goodness of fit tests and 2x2 contingency tables which are the simplest of the generalized nxm contingency tables. Degrees of Freedom and P<0.05 for Significance Testing: An Introduction will be given to the meaning of P<0.05 in relation to significance testing and the use of tables of critical values of a test statistic (eg. chi-squared) which are given as a function of degrees of freedom and P-values. Survival Rate Calculations for Grouped and Ungrouped Data: The life-table method (sometimes termed the actuarial method) will be explained for both grouped data (eg. survival times grouped in annual intervals for patients who have died and for those who are still alive or lost to follow-up) and for ungrouped data (when individual survival times are used). The method for ungrouped data is variously termed the Kaplan-Meier or Product Limit method. Logrank Test: This is the most useful test for comparison of the survival experience of two groups of patients and its use will be explained. In part the computation is similar to that for the Kaplan-Meier/Product Limit method

  12. Biostatistics with emphasis on life table survival rate calculations (including Kaplan Meier) and the logrank test

    Energy Technology Data Exchange (ETDEWEB)

    Mould, Richard F

    1995-07-01

    Purpose/Objective: To explain some of the most useful statistical calculation procedures which are relevant to radiation oncologists and to provide insights on what tests and procedures should be used in various situations such as when survival rates and their associated standard errors have to be determined. To describe some of the problems and pitfalls in clinical trial designs which have to be overcome if a trial is to have the possibility of reaching a successful conclusion. To review methods of computing criteria to quantitatively describe criteria of success (eg. quality of life, long-term survival, cure) of radiation oncology and to suggest possible future statistical improvements in this area. Chi-Squared Test: The chi-squared test is probably the most useful of the tests of statistical significance for the radiation oncologist. Applications will be described, including goodness of fit tests and 2x2 contingency tables which are the simplest of the generalized nxm contingency tables. Degrees of Freedom and P<0.05 for Significance Testing: An Introduction will be given to the meaning of P<0.05 in relation to significance testing and the use of tables of critical values of a test statistic (eg. chi-squared) which are given as a function of degrees of freedom and P-values. Survival Rate Calculations for Grouped and Ungrouped Data: The life-table method (sometimes termed the actuarial method) will be explained for both grouped data (eg. survival times grouped in annual intervals for patients who have died and for those who are still alive or lost to follow-up) and for ungrouped data (when individual survival times are used). The method for ungrouped data is variously termed the Kaplan-Meier or Product Limit method. Logrank Test: This is the most useful test for comparison of the survival experience of two groups of patients and its use will be explained. In part the computation is similar to that for the Kaplan-Meier/Product Limit method.

  13. The development and validation of control rod calculation methods

    International Nuclear Information System (INIS)

    Rowlands, J.L.; Sweet, D.W.; Franklin, B.M.

    1979-01-01

    Fission rate distributions have been measured in the zero power critical facility, ZEBRA, for a series of eight different arrays of boron carbide control rods. Diffusion theory calculations have been compared with these measurements. The normalised fission rates differ by up to about 30% in some regions, between the different arrays, and these differences are well predicted by the calculations. A development has been made to a method used to produce homogenised cross sections for lattice regions containing control rods. Calculations show that the method also reproduces the reaction rate within the rod and the fission rate dip at the surface of the rod in satisfactory agreement with the more accurate calculations which represent the fine structure of the rod. A comparison between diffusion theory and transport theory calculations of control rod reactivity worths in the CDFR shows that for the standard design method the finite mesh approximation and the difference between diffusion theory and transport theory (the transport correction) tend to cancel and result in corrections to be applied to the standard mesh diffusion theory calculations of about +- 2% or less. This result applies for mesh centred finite difference diffusion theory codes and for the arrays of natural boron carbide control rods for which the calculations were made. Improvements have also been made to the effective diffusion coefficients used in diffusion theory calculations for control rod followers and these give satisfactory agreement with transport theory calculations. (U.K.)

  14. Lambda-guided calculation method (LGC method) for xenon/CT CBF

    Energy Technology Data Exchange (ETDEWEB)

    Sase, Shigeru [Anzai Medical Co., Ltd., Tokyo (Japan); Honda, Mitsuru; Kushida, Tsuyoshi; Seiki, Yoshikatsu; Machida, Keiichi; Shibata, Iekado [Toho Univ., Tokyo (Japan). School of Medicine

    2001-12-01

    A quantitative CBF calculation method for xenon/CT was developed by logically estimating time-course change rate (rate constant) of arterial xenon concentration from that of end-tidal xenon concentration. A single factor ({gamma}) was introduced to correlate the end-tidal rate constant (Ke) with the arterial rate constant (Ka) in a simplified equation. This factor ({gamma}) is thought to reflect the diffusing capacity of the lung for xenon. When an appropriate value is given to {gamma}, it is possible to calculate the arterial rate constant (Calculated Ka) from Ke. To determine {gamma} for each xenon/CT CBF examination, a procedure was established which utilizes the characteristics of white matter lambda; lambda refers to xenon brain-blood partition coefficient. Xenon/CT studies were performed on four healthy volunteers. Hemispheric CBF values (47.0{+-}9.0 ml/100 g/min) with use of Calculated Ka were close to the reported normative values. For a 27-year-old healthy man, the rate constant for the common carotid artery was successfully measured and nearly equal to Calculated Ka. The authors conclude the method proposed in this work, lambda-guided calculation method, could make xenon/CT CBF substantially reliable and quantitative by effective use of end-tidal xenon. (author)

  15. Lambda-guided calculation method (LGC method) for xenon/CT CBF

    International Nuclear Information System (INIS)

    Sase, Shigeru; Honda, Mitsuru; Kushida, Tsuyoshi; Seiki, Yoshikatsu; Machida, Keiichi; Shibata, Iekado

    2001-01-01

    A quantitative CBF calculation method for xenon/CT was developed by logically estimating time-course change rate (rate constant) of arterial xenon concentration from that of end-tidal xenon concentration. A single factor (γ) was introduced to correlate the end-tidal rate constant (Ke) with the arterial rate constant (Ka) in a simplified equation. This factor (γ) is thought to reflect the diffusing capacity of the lung for xenon. When an appropriate value is given to γ, it is possible to calculate the arterial rate constant (Calculated Ka) from Ke. To determine γ for each xenon/CT CBF examination, a procedure was established which utilizes the characteristics of white matter lambda; lambda refers to xenon brain-blood partition coefficient. Xenon/CT studies were performed on four healthy volunteers. Hemispheric CBF values (47.0±9.0 ml/100 g/min) with use of Calculated Ka were close to the reported normative values. For a 27-year-old healthy man, the rate constant for the common carotid artery was successfully measured and nearly equal to Calculated Ka. The authors conclude the method proposed in this work, lambda-guided calculation method, could make xenon/CT CBF substantially reliable and quantitative by effective use of end-tidal xenon. (author)

  16. Experimental verification of methods for gamma dose rate calculations in the vicinity of containers with the RA reactor spent fuel elements

    International Nuclear Information System (INIS)

    Milosevic, M.; Cupac, S.; Pesic, M.

    2005-01-01

    The methodology for equivalent gamma dose rate determination on the outer surface of existing containers with the spent fuel elements of the RA reactor is briefly summarised, and experimental verification of this methodology in the field of gamma rays near the aluminium channel with spent fuel elements lifted from the stainless steel containers no. 275 in the RA reactor hall is presented. The proposed methodology is founded on: the existing fuel burnup data base; methods and models for the photon source determination in the RA reactor spent fuel elements developed in the Vinca Institute, and validated Monte Carlo codes for the equivalent gamma dose rate calculations. (author) [sr

  17. Studies on the distribution of radioactivity in the organism during constant intravenous infusion of tracer amino acids and on the calculation of the rate of tissue protein synthesis in rats

    International Nuclear Information System (INIS)

    Simon, O.; Bergner, H.; Wolf, E.

    1978-01-01

    Male wistar rats (100 p body weight) were infused into the tail vein with 14 C-leucine and 14 C-lysine simultaneously for 0.5; 1.0; 2.0; 3.0; 4.5; 6.0 and 7.0 hours. At the end of the infusion the specific radioactivity was determined of the free leucine and lysine in the blood plasma, liver, M. gastrocnemius, small intestine, and colon as well as of the protein-bound leucine and lysine. In all the tissues tested the specific radioactivity of the free amino acids attained a plateau during the 6-hour and 7-hour infusions. The rate constants for the increase were calculated for each organ tested. The two amino acids used are suitable for calculating the fractional rate of protein synthesis in tissues. The values of the fractional rate of protein synthesis calculated on the basis of the 6-hour and 7-hour infusions were: 54+-7.7%/day for the liver, 9.4+-1.2%/day for the muscles, 89+-12.2%/day for the small intestine, and 42+-5.9%/day for the colon. The simultaneous application of two tracer amino acids is recommendable for estimating the precursor pool of the protein synthesis and the more accurate calculation of the rate of protein synthesis. (author)

  18. Evaluation of methodologies for the calculation of leak rates for pressure retaining components with crack-like leaks; Bewertung von Methoden zur Berechnung von Leckraten fuer druckfuehrende Komponenten mit rissartigen Lecks

    Energy Technology Data Exchange (ETDEWEB)

    Sievers, Juergen; Heckmann, Klaus; Blaesius, Christoph

    2015-06-15

    For the demonstration of break preclusion for pressure retaining components in nuclear power plants, the nuclear safety standard KTA 3206 determines also the requirements for the leak-before-break verification. For this procedure, it has to be ensured that a wall-penetrating crack is subcritical with respect to instable growth, and that the resulting leakage under stationary operation conditions can be detected by a leak detection system. Within the scope of the project 3613R01332 analyses with respect to conservative estimates of the leak rates in case of detections regarding break preclusion were performed by means of leak rate models being available at GRS. For this purpose, conservative assumptions in the procedure were quantified by comparative calculations concerning selected leak rate experiments and the requirements regarding the determination of leak rates indicated in the KTA 3206 were verified and specified. Moreover, the models were extended and relevant recommendations for the calculation procedure were developed. During the investigations of leak rate tests the calculation methods were validated, qualified by means of both examples indicated in KTA 3206 and applied to a postulated leak accident in the cooling circuit of a PWR. For the calculation of leak rates several simplified solution methods which are included in the GRS program WinLeck were applied, and for the simulation of a leak accident the large-scale programs ANSYS Mechanical and ATHLET (thermohydraulics program developed by GRS) were used. When applying simplified methods for the calculation of leak rates using the limiting curve for the friction factor which has been derived during the project and which is included in the KTA 3206 attention has to be paid to the fact that in case of small flow lengths the entrance loss can dominate compared to the friction loss. However, the available data do not suffice in order to make a quantitative statement with respect to limits of applicability

  19. Calculation of turnover rates in stable-isotope studies

    International Nuclear Information System (INIS)

    Wootton, R.; Ford, G.C.; Cheng, K.N.; Halliday, D.

    1985-01-01

    In a comparison of glucose turnover measured with 2 H-glucose and with 13 C-glucose Tserng and Kalhan used five apparently different equations and obtained conflicting answers. There is, however, no difference in principle between the use of a stable isotope as a tracer and the use of a radioactive isotope, and the rate of appearance of tracee in a steady-state system (the turnover) can therefore be shown to be proportional to the equilibrium dilution of the infused tracer. Because the sensitivity of measurement of this dilution made using a gas chromatograph-mass spectrometer is lower than that made by radioactivity measurement, the contribution to the measured turnover rate due to the infusate cannot be neglected, as it usually is in radioisotope work. A convenient calibration curve to establish this dilution is the mole ratio of the pure infusate against the area ratio for the relevant ions. Tserng and Kalhan's apparently conflicting results for glucose-turnover using 13 C-glucose as the tracer can all be shown to amount to approximately 11.6 μmol min -1 kg -1 . This value is only slightly lower (0.05 2 H-glucose as the tracer and supports the use of 13 C-glucose as an alternative. (author)

  20. Willow growing - Methods of calculation and profitability

    International Nuclear Information System (INIS)

    Rosenqvist, H.

    1997-01-01

    The calculation method presented here makes it possible to conduct profitability comparisons between annual and perennial crops and in addition take the planning situation into account. The method applied is a modified total step calculation. The difference between a traditional total step calculation and the modified version is the way in which payments and disbursements are taken into account over a period of several years. This is achieved by combining the present value method and the annuity method. The choice of interest rate has great bearing on the result in perennial calculations. The various components influencing the interest rate are analysed and factors relating to the establishment of the interest rate in different situations are described. The risk factor can be an important variable component of the interest rate calculation. Risk is also addressed from an approach in accordance with portfolio theory. The application of the methods sheds light on the profitability of Salix cultivation from the viewpoint of business economics, and also how different factors influence the profitability of Salix cultivation. Aspects studied are harvesting intervals, the importance of yield level, the competitiveness of Salix versus grain cultivation, the influence of income taxes on profitability etc. Methods for evaluation of activities concerning cultivation of a perennial crop are described and also involve the application of nitrogen fertilization to Salix cultivation. Studies have been performed using these methods to look into nitrogen fertilizer profitability in Salix cultivation during the first rotation period. Nitrogen fertilizer profitability has been investigated involving both production functions and cost calculations, taking the year fertilization into consideration. 72 refs., 2 figs., 52 tabs

  1. Calculations with spectroscopic accuracy for energies, transition rates, hyperfine interaction constants, and Landé gJ-factors in nitrogen-like Kr XXX

    Science.gov (United States)

    Wang, K.; Li, S.; Jönsson, P.; Fu, N.; Dang, W.; Guo, X. L.; Chen, C. Y.; Yan, J.; Chen, Z. B.; Si, R.

    2017-01-01

    Extensive self-consistent multi-configuration Dirac-Fock (MCDF) calculations and second-order many-body perturbation theory (MBPT) calculations are performed for the lowest 272 states belonging to the 2s22p3, 2s2p4, 2p5, 2s22p23l, and 2s2p33l (l=s, p, d) configurations of N-like Kr XXX. Complete and consistent data sets of level energies, wavelengths, line strengths, oscillator strengths, lifetimes, AJ, BJ hyperfine interaction constants, Landé gJ-factors, and electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), magnetic quadrupole (M2) transition rates among all these levels are given. The present MCDF and MBPT results are compared with each other and with other available experimental and theoretical results. The mean relative difference between our two sets of level energies is only about 0.003% for these 272 levels. The accuracy of the present calculations are high enough to facilitate identification of many observed spectral lines. These accurate data can be served as benchmark for other calculations and can be useful for fusion plasma research and astrophysical applications.

  2. A Novel Hybrid Similarity Calculation Model

    Directory of Open Access Journals (Sweden)

    Xiaoping Fan

    2017-01-01

    Full Text Available This paper addresses the problems of similarity calculation in the traditional recommendation algorithms of nearest neighbor collaborative filtering, especially the failure in describing dynamic user preference. Proceeding from the perspective of solving the problem of user interest drift, a new hybrid similarity calculation model is proposed in this paper. This model consists of two parts, on the one hand the model uses the function fitting to describe users’ rating behaviors and their rating preferences, and on the other hand it employs the Random Forest algorithm to take user attribute features into account. Furthermore, the paper combines the two parts to build a new hybrid similarity calculation model for user recommendation. Experimental results show that, for data sets of different size, the model’s prediction precision is higher than the traditional recommendation algorithms.

  3. Calculation of Gilbert damping in ferromagnetic films

    Directory of Open Access Journals (Sweden)

    Edwards D. M.

    2013-01-01

    Full Text Available The Gilbert damping constant in the phenomenological Landau-Lifshitz-Gilbert equation which describes the dynamics of magnetization, is calculated for Fe, Co and Ni bulk ferromagnets, Co films and Co/Pd bilayers within a nine-band tight-binding model with spin-orbit coupling included. The calculational effciency is remarkably improved by introducing finite temperature into the electronic occupation factors and subsequent summation over the Matsubara frequencies. The calculated dependence of Gilbert damping constant on scattering rate for bulk Fe, Co and Ni is in good agreement with the results of previous ab initio calculations. Calculations are reported for ferromagnetic Co metallic films and Co/Pd bilayers. The dependence of the Gilbert damping constant on Co film thickness, for various scattering rates, is studied and compared with recent experiments.

  4. ECP evaluation by water radiolysis and ECP model calculations

    Energy Technology Data Exchange (ETDEWEB)

    Hanawa, S.; Nakamura, T.; Uchida, S. [Japan Atomic Energy Agency, Tokai-mura, Ibaraki (Japan); Kus, P.; Vsolak, R.; Kysela, J. [Nuclear Research Inst. Rez plc, Rez (Czech Republic)

    2010-07-01

    In-pile ECP measurements data was evaluated by water radiolysis calculations. The data was obtained by using an in-pile loop in an experimental reactor, LVR-15, at the Nuclear Research Institute (NRI) in Czech Republic. Three types of ECP sensors, a Pt electrode, an Ag/AgCl sensor and a zirconia membrane sensor containing Ag/Ag{sub 2}O were used at several levels of the irradiation rig at various neutron flux and gamma rates. For water radiolysis calculation, the in-pile loop was modeled to several nodes following their design specifications, operating conditions such as flow rates, dose rate distributions of neutron and gamma-ray and so on. Concentration of chemical species along the water flow was calculated by a radiolysis code, WRAC-J. The radiolysis calculation results were transferred to an ECP model. In the model, anodic and cathodic current densities were calculated with combination of an electrochemistry model and an oxide film growth model. The measured ECP data were compared with the radiolysis/ECP calculation results, and applicability the of radiolysis model was confirmed. In addition, anomalous phenomenon appears in the in-pile loop was also investigated by radiolysis calculations. (author)

  5. Calculation of radiation dose rate above water layer of Interim Spent Fuel Storage Jaslovske Bohunice by the point Kernels (VISIPLAN) and Monte Carlo (MCNP4C) methods

    International Nuclear Information System (INIS)

    Slavik, O.; Kucharova, D.; Listjak, M.; Fueloep, M.

    2008-01-01

    The aim of this paper is to evaluate maximal dose rate (DR) of gamma radiation above different configurations of reservoirs with spent nuclear fuel with cooling period 1.8 year and to compare by buildup factor method (Visiplan) and Monte Carlo simulations and to appreciate influence of scattered photons in the case of calculation of fully filled fuel transfer storage (FTS). On the ground of performed accounts it was shown, that relative contributions of photons from adjacent reservoirs are in the case buildup factor method (Visiplan) similar to Monte Carlo simulations. It means, that Visiplan can be used also for valuation of contributions of of dose rates from neighbouring reservoirs. It was shown, that calculations of DR by Visiplan are conservatively overestimated for this source of radiation and thickness of shielding approximately 2.6 - 3 times. Also following these calculations resulted, that by storage of reservoirs with cooling period 1.8 years in FTS is not needed any additional protection measures for workers against primal safety report. Calculated DR also above fully filled FTS by these reservoirs in Jaslovske Bohunice is very low on the level 0.03 μSv/h. (authors)

  6. Calculation of radiation dose rate above water layer of Interim Spent Fuel Storage Jaslovske Bohunice by the point Kernels (VISIPLAN) and Monte Carlo (MCNP4C) methods

    International Nuclear Information System (INIS)

    Slavik, O.; Kucharova, D.; Listjak, M.; Fueloep, M.

    2009-01-01

    The aim of this paper is to evaluate maximal dose rate (DR) of gamma radiation above different configurations of reservoirs with spent nuclear fuel with cooling period 1.8 year and to compare by buildup factor method (Visiplan) and Monte Carlo simulations and to appreciate influence of scattered photons in the case of calculation of fully filled fuel transfer storage (FTS). On the ground of performed accounts it was shown, that relative contributions of photons from adjacent reservoirs are in the case buildup factor method (Visiplan) similar to Monte Carlo simulations. It means, that Visiplan can be used also for valuation of contributions of of dose rates from neighbouring reservoirs. It was shown, that calculations of DR by Visiplan are conservatively overestimated for this source of radiation and thickness of shielding approximately 2.6 - 3 times. Also following these calculations resulted, that by storage of reservoirs with cooling period 1.8 years in FTS is not needed any additional protection measures for workers against primal safety report. Calculated DR also above fully filled FTS by these reservoirs in Jaslovske Bohunice is very low on the level 0.03 μSv/h. (authors)

  7. Experimental measures of the energy rate absorbed in the aluminium and the comparison with the calculation using factors of dose and carrier of electrons by means of MCNP code

    International Nuclear Information System (INIS)

    Federico, Claudio A.; Vieira, Wilson J.; Rigolon, Leda S.Y.; Geraldo, Luiz P.

    2000-01-01

    In this paper are presented the results of a Monte Carlo calculation for the energy deposition rate in aluminum plates, when a collimated beam of gamma-rays produced by thermal neutrons capture in nickel target passes through them. The absorbed dose rate as a function of the aluminum thickness crossed by the gamma beam has been measured by using CaSO e :Dy thermoluminescent dosimeters. The capture gamma ray beam was extracted from a tangential beam tube of the IPEN's IEA-R1 2MW research reactor. The absorbed dose calculation was performed employing the Monte Carlo N-particle transport code (MCNP) and two methods of calculation: the simulated gamma ray flux multiplied by a dose conversion factor, and the simulated electron flux multiplied by the collision linear energy loss. The calculation results obtained by the electron transport have shown a good agreement with the experimental measurements. For deeper layers (more than 10 mm aluminum thickness), the calculation using the gamma ray flux multiplied by dose conversion factors, as well the calculation employing the electron transport, exhibit the same decreasing trade observed in experimental data, differing by a normalization factor of approximately 1.4. However, for layers nearer the material surface, the calculation using photon flux produces an overestimation of that using the electron transport as well as of the experimental results. (author)

  8. Ab initio calculation of transition state normal mode properties and rate constants for the H(T)+CH4(CD4) abstraction and exchange reactions

    International Nuclear Information System (INIS)

    Schatz, G.C.; Walch, S.P.; Wagner, A.F.

    1980-01-01

    We present ab initio (GVB--POL--CI) calculations for enough of the region about the abstraction and exchange saddle points for H(T)+CH 4 (CD 4 ) to perform a full normal mode analysis of the transition states. The resulting normal mode frequencies are compared to four other published surfaces: an ab initio UHF--SCF calculation by Carsky and Zahradnik, a semiempirical surface by Raff, and two semiempirical surfaces by Kurylo, Hollinden, and Timmons. Significant quantitative and qualitative differences exist between the POL--CI results and those of the other surfaces. Transition state theory rate constants and vibrationally adiabatic reaction threshold energies were computed for all surfaces and compared to available experimental values. For abstraction, the POL--CI rates are in good agreement with experimental rates and in better agreement than are the rates of any of the other surfaces. For exchange, uncertainties in the experimental values and in the importance of vibrationally nonadiabatic effects cloud the comparison of theory to experiment. Tentative conclusions are that the POL--CI barrier is too low by several kcal. Unless vibrationaly nonadiabatic effects are severe, the POL--CI surface is still in better agreement with experiment than are the other surfaces. The rates for a simple 3-atom transition state theory model (where CH 3 is treated as an atom) are compared to the rates for the full 6-atom model. The kinetic energy coupling of reaction coordinate modes to methyl group modes is identified as being of primary importance in determining the accuracy of the 3-atom model for this system. Substantial coupling in abstraction, but not exchange, causes the model to fail for abstraction but succeed for exchange

  9. Secondary standard dosimetry system with automatic dose/rate calculation

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Bernhart, J.; Stehno, G.; Klosch, W.

    1980-01-01

    A versatile and automated secondary standard instrument has been designed for quick and accurate dose/rate measurement in a wide range of radiation intensity and quality (between 1 μR and 100 kR; 0.2 nC/kg - 20C/kg) for protection and therapy level dosimetry. The system is based on a series of secondary standard ionization chambers connected to a precision digital current integrator with microprocessor circuitry for data evaluation and control. Input of measurement parameters and calibration factors stored in an exchangeable memory chip provide computation of dose/rate values in the desired units. The ionization chambers provide excellent long-term stability and energy response and can be used with internal check sources to test validity of calibration. The system is a useful tool particularly for daily measurements in a secondary standard dosimetry laboratory or radiation therapy center. (H.K.)

  10. 40 CFR 1065.650 - Emission calculations.

    Science.gov (United States)

    2010-07-01

    ... field testing, you may calculate the ratio of total mass to total work, where these individual values... negative work rate values in the integration to calculate total work from that work path. Some work paths may result in a negative total work. Include negative total work values from any work path in the...

  11. A software solution to estimate the SEU-induced soft error rate for systems implemented on SRAM-based FPGAs

    International Nuclear Information System (INIS)

    Wang Zhongming; Lu Min; Yao Zhibin; Guo Hongxia

    2011-01-01

    SRAM-based FPGAs are very susceptible to radiation-induced Single-Event Upsets (SEUs) in space applications. The failure mechanism in FPGA's configuration memory differs from those in traditional memory device. As a result, there is a growing demand for methodologies which could quantitatively evaluate the impact of this effect. Fault injection appears to meet such requirement. In this paper, we propose a new methodology to analyze the soft errors in SRAM-based FPGAs. This method is based on in depth understanding of the device architecture and failure mechanisms induced by configuration upsets. The developed programs read in the placed and routed netlist, search for critical logic nodes and paths that may destroy the circuit topological structure, and then query a database storing the decoded relationship of the configurable resources and corresponding control bit to get the sensitive bits. Accelerator irradiation test and fault injection experiments were carried out to validate this approach. (semiconductor integrated circuits)

  12. Application of numerical method in calculating the internal rate of return of joint venture investment using diminishing musyarakah model

    Science.gov (United States)

    Ruslan, Siti Zaharah Mohd; Jaffar, Maheran Mohd

    2017-05-01

    Islamic banking in Malaysia offers variety of products based on Islamic principles. One of the concepts is a diminishing musyarakah. The concept of diminishing musyarakah helps Muslims to avoid transaction which are based on riba. The diminishing musyarakah can be defined as an agreement between capital provider and entrepreneurs that enable entrepreneurs to buy equity in instalments where profits and losses are shared based on agreed ratio. The objective of this paper is to determine the internal rate of return (IRR) for a diminishing musyarakah model by applying a numerical method. There are several numerical methods in calculating the IRR such as by using an interpolation method and a trial and error method by using Microsoft Office Excel. In this paper we use a bisection method and secant method as an alternative way in calculating the IRR. It was found that the diminishing musyarakah model can be adapted in managing the performance of joint venture investments. Therefore, this paper will encourage more companies to use the concept of joint venture in managing their investments performance.

  13. Empirical Formulae for The Calculation of Austenite Supercooled Transformation Temperatures

    Directory of Open Access Journals (Sweden)

    Trzaska J.

    2015-04-01

    Full Text Available The paper presents empirical formulae for the calculation of austenite supercooled transformation temperatures, basing on the chemical composition, austenitising temperature and cooling rate. The multiple regression method was used. Four equations were established allowing to calculate temperature of the start area of ferrite, perlite, bainite and martensite at the given cooling rate. The calculation results obtained do not allow to determine the cooling rate range of ferritic, pearlitic, bainitic and martensite transformations. Classifiers based on logistic regression or neural network were established to solve this problem.

  14. Calculating Outcrossing Rates used in Decision Support Systems for Ships

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam

    2008-01-01

    Onboard decision support systems (DSS) are used to increase the operational safety of ships. Ideally, DSS can estimate - in the statistical sense - future ship responses on a time scale of the order of 1-3 hours taking into account speed and course changes. The calculations depend on both...... analysis, and the paper derives and describes the main ideas. The concept is illustrated by an example, where the limit state of a non-linear ship response is considered. The results from the parallel system analysis are in agreement with corresponding Monte Carlo simulations. However, the computational...

  15. On the accuracy of instantaneous gas exchange rates, energy expenditure and respiratory quotient calculations obtained from indirect whole room calorimetry

    International Nuclear Information System (INIS)

    Gribok, Andrei; Rumpler, William; Hoyt, Reed; Buller, Mark

    2013-01-01

    This paper analyzes the accuracy of metabolic rate calculations performed in the whole room indirect calorimeter using the molar balance equations. The equations are treated from the point of view of cause–effect relationship where the gaseous exchange rates representing the unknown causes need to be inferred from a known, noisy effect—gaseous concentrations. Two methods of such inference are analyzed. The first method is based on the previously published regularized deconvolution of the molar balance equation and the second one, proposed in this paper, relies on regularized differentiation of gaseous concentrations. It is found that both methods produce similar results for the absolute values of metabolic variables and their accuracy. The uncertainty for O 2 consumption rate is found to be 7% and for CO 2 production-–3.2%. The uncertainties in gaseous exchange rates do not depend on the absolute values of O 2 consumption and CO 2 production. In contrast, the absolute uncertainty in respiratory quotient is a function of the gaseous exchange rates and varies from 9.4% during the night to 2.3% during moderate exercise. The uncertainty in energy expenditure was found to be 5.9% and independent of the level of gaseous exchange. For both methods, closed form analytical formulas for confidence intervals are provided allowing quantification of uncertainty for four major metabolic variables in real world studies. (paper)

  16. On the accuracy of instantaneous gas exchange rates, energy expenditure and respiratory quotient calculations obtained from indirect whole room calorimetry.

    Science.gov (United States)

    Gribok, Andrei; Hoyt, Reed; Buller, Mark; Rumpler, William

    2013-06-01

    This paper analyzes the accuracy of metabolic rate calculations performed in the whole room indirect calorimeter using the molar balance equations. The equations are treated from the point of view of cause-effect relationship where the gaseous exchange rates representing the unknown causes need to be inferred from a known, noisy effect-gaseous concentrations. Two methods of such inference are analyzed. The first method is based on the previously published regularized deconvolution of the molar balance equation and the second one, proposed in this paper, relies on regularized differentiation of gaseous concentrations. It is found that both methods produce similar results for the absolute values of metabolic variables and their accuracy. The uncertainty for O2 consumption rate is found to be 7% and for CO2 production--3.2%. The uncertainties in gaseous exchange rates do not depend on the absolute values of O2 consumption and CO2 production. In contrast, the absolute uncertainty in respiratory quotient is a function of the gaseous exchange rates and varies from 9.4% during the night to 2.3% during moderate exercise. The uncertainty in energy expenditure was found to be 5.9% and independent of the level of gaseous exchange. For both methods, closed form analytical formulas for confidence intervals are provided allowing quantification of uncertainty for four major metabolic variables in real world studies.

  17. Selection of skin dose calculation methodologies

    International Nuclear Information System (INIS)

    Farrell, W.E.

    1987-01-01

    This paper reports that good health physics practice dictates that a dose assessment be performed for any significant skin contamination incident. There are, however, several methodologies that could be used, and while there is probably o single methodology that is proper for all cases of skin contamination, some are clearly more appropriate than others. This can be demonstrated by examining two of the more distinctly different options available for estimating skin dose the calculational methods. The methods compiled by Healy require separate beta and gamma calculations. The beta calculational method is the derived by Loevinger, while the gamma dose is calculated from the equation for dose rate from an infinite plane source with an absorber between the source and the detector. Healy has provided these formulas in graphical form to facilitate rapid dose rate determinations at density thicknesses of 7 and 20 mg/cm 2 . These density thicknesses equate to the regulatory definition of the sensitive layer of the skin and a more arbitrary value to account of beta absorption in contaminated clothing

  18. 40 CFR 1033.530 - Duty cycles and calculations.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Duty cycles and calculations. 1033.530... CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.530 Duty cycles and calculations. This section describes how to apply the duty cycle to measured emission rates to calculate cycle...

  19. Whole core burnup calculations using `MCNP`

    Energy Technology Data Exchange (ETDEWEB)

    Haran, O; Shaham, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    Core parameters such as the reactivity, the power distribution and different reactivity coefficients calculated in simulations play an important role in the nuclear reactor handling. Operational safety margins are decided upon, based on the calculated parameters. Thus, the ability to accurately calculate those parameters is of uppermost importance. Such ability exists for fresh cores, using the Monte-Carlo method. The change in the core parameters that results from the core burnup is nowadays calculated within transport codes that simplifies the transport process by using approximations such as the diffusion approximation. The inaccuracy in the burned core parameters arising from the use of such approximations is hard to quantify, leading to an increased gap between the operational routines and the safety limits. A Monte Carlo transport code that caries out accurate static calculations in three dimensional geometries using continuous-energy neutron cross-section data such as the MCNP can be used to generate accurate reaction rates for burnup purposes. Monte Carlo method is statistical by nature, so that the reaction rates calculated will be accurate only to a certain known extent. The purpose of this work was to create a burnup routine that uses the capabilities of the Monte Carlo based MCNP code. It should be noted that burnup using Monte Carlo has been reported in the literatures, but this work is the result of an independent effort (authors).

  20. Whole core burnup calculations using 'MCNP'

    International Nuclear Information System (INIS)

    Haran, O.; Shaham, Y.

    1996-01-01

    Core parameters such as the reactivity, the power distribution and different reactivity coefficients calculated in simulations play an important role in the nuclear reactor handling. Operational safety margins are decided upon, based on the calculated parameters. Thus, the ability to accurately calculate those parameters is of uppermost importance. Such ability exists for fresh cores, using the Monte-Carlo method. The change in the core parameters that results from the core burnup is nowadays calculated within transport codes that simplifies the transport process by using approximations such as the diffusion approximation. The inaccuracy in the burned core parameters arising from the use of such approximations is hard to quantify, leading to an increased gap between the operational routines and the safety limits. A Monte Carlo transport code that caries out accurate static calculations in three dimensional geometries using continuous-energy neutron cross-section data such as the MCNP can be used to generate accurate reaction rates for burnup purposes. Monte Carlo method is statistical by nature, so that the reaction rates calculated will be accurate only to a certain known extent. The purpose of this work was to create a burnup routine that uses the capabilities of the Monte Carlo based MCNP code. It should be noted that burnup using Monte Carlo has been reported in the literatures, but this work is the result of an independent effort (authors)