WorldWideScience

Sample records for upper sentinel butte

  1. Geology of the upper part of the Fort Union Group (Paleocene), Williston Basin, with reference to uranium

    International Nuclear Information System (INIS)

    Jacob, A.F.

    1976-01-01

    Tabular sandstone beds in the Sentinel Butte Formation are thicker (as much as 30 m thick), more laterally extensive (more than 2 km wide in many places), and more abundant than in the Tongue River Formation. This indicates that high-sinuosity streams were more abundant where the Sentinel Butte Formation was deposited, and the streams were deeper and occupied wider meander belts, as would be found on the landward part of the delta plain. Siltstone, claystone, lignite, and a small amount of limestone were deposited on natural levees, crevasse splays, and in flood basins. The vertical arrangement of the two formations indicates a progradation of a large deltaic complex into the sea in which the Cannonball Formation was deposited. Sandstone in the Tongue River Formation classifies mostly as carbonate litharenite, and the fine fraction of the formation consists mostly of mica-group minerals, some kaolinite-group minerals, and a little montmorillonite. Sandstone in the Sentinel Butte Formation classifies mostly as volcanic litharenite, and the fine fraction consists mostly of montmorillonite, some kaolinite-group minerals, and a little of the mica-group minerals. The highest-grade uranium deposits in North Dakota are in the Sentinel Butte Formation in the area of the Little Missouri River escarpment in eastern Billings and northwestern Stark Counties. Little uranium has been found in the Tongue River Formation. Uranium may be more abundant in the Sentinel Butte Formation because of the abundance of glassy volcanic matter, which has now been largely altered to montmorillonite, and the abundance of fragments of volcanic rock. Weathering of the upper part of the Sentinel Butte Formation during formation of the Eocene paleosol in the northern Great Plains may have mobilized uranium that was deposited in the formation below the paleosol before deposition of the overlying Oligocene and younger sediment

  2. Optimization and Prediction of Angular Distortion and Weldment Characteristics of TIG Square Butt Joints

    Science.gov (United States)

    Narang, H. K.; Mahapatra, M. M.; Jha, P. K.; Biswas, P.

    2014-05-01

    Autogenous arc welds with minimum upper weld bead depression and lower weld bead bulging are desired as such welds do not require a second welding pass for filling up the upper bead depressions (UBDs) and characterized with minimum angular distortion. The present paper describes optimization and prediction of angular distortion and weldment characteristics such as upper weld bead depression and lower weld bead bulging of TIG-welded structural steel square butt joints. Full factorial design of experiment was utilized for selecting the combinations of welding process parameter to produce the square butts. A mathematical model was developed to establish the relationship between TIG welding process parameters and responses such as upper bead width, lower bead width, UBD, lower bead height (bulging), weld cross-sectional area, and angular distortions. The optimal welding condition to minimize UBD and lower bead bulging of the TIG butt joints was identified.

  3. Interview with Gavin Butt

    DEFF Research Database (Denmark)

    Hasse Jørgensen, Stina; Alexandra Sofie, Jönsson

    2008-01-01

    We have interviewed Gavin Butt about his research interest in the cross-field between performance and performativity in the visual arts: queer theory, queer cultures and their histories, post-second world war U.S. art, contemporary art and critical theory.......We have interviewed Gavin Butt about his research interest in the cross-field between performance and performativity in the visual arts: queer theory, queer cultures and their histories, post-second world war U.S. art, contemporary art and critical theory....

  4. High risk of non-sentinel node metastases in a group of breast cancer patients with micrometastases in the sentinel node.

    Science.gov (United States)

    Tvedskov, Tove Filtenborg; Jensen, Maj-Britt; Lisse, Ida Marie; Ejlertsen, Bent; Balslev, Eva; Kroman, Niels

    2012-11-15

    Axillary lymph node dissection (ALND) in breast cancer patients with positive sentinel nodes is under debate. We aimed to establish two models to predict non-sentinel node (NSN) metastases in patients with micrometastases or isolated tumor cells (ITC) in sentinel nodes, to guide the decision for ALND. A total of 1,577 breast cancer patients with micrometastases and 304 with ITC in sentinel nodes, treated by sentinel lymph node dissection and ALND in 2002-2008 were identified in the Danish Breast Cancer Cooperative Group database. Risk of NSN metastases was calculated according to clinicopathological variables in a logistic regression analysis. We identified tumor size, proportion of positive sentinel nodes, lymphovascular invasion, hormone receptor status and location of tumor in upper lateral quadrant of the breast as risk factors for NSN metastases in patients with micrometastases. A model based on these risk factors identified 5% of patients with a risk of NSN metastases on nearly 40%. The model was however unable to identify a subgroup of patients with a very low risk of NSN metastases. Among patients with ITC, we identified tumor size, age and proportion of positive sentinel nodes as risk factors. A model based on these risk factors identified 32% of patients with risk of NSN metastases on only 2%. Omission of ALND would be acceptable in this group of patients. In contrast, ALND may still be beneficial in the subgroup of patients with micrometastases and a high risk of NSN metastases. Copyright © 2012 UICC.

  5. Sentinel node detection in pre-operative axillary staging.

    Science.gov (United States)

    Trifirò, Giuseppe; Viale, Giuseppe; Gentilini, Oreste; Travaini, Laura Lavinia; Paganelli, Giovanni

    2004-06-01

    The concept of sentinel lymph node biopsy in breast cancer surgery is based on the fact that the tumour drains in a logical way via the lymphatic system, from the first to upper levels. Since axillary node dissection does not improve the prognosis of patients with breast cancer, sentinel lymph node biopsy might replace complete axillary dissection for staging of the axilla in clinically N0 patients. Sentinel lymph node biopsy would represent a significant advantage as a minimally invasive procedure, considering that about 70% of patients are found to be free from metastatic disease, yet axillary node dissection can lead to significant morbidity. Subdermal or peritumoural injection of small aliquots (and very low activity) of radiotracer is preferred to intratumoural administration, and (99m)Tc-labelled colloids with most of the particles in the 100-200 nm size range would be ideal for radioguided sentinel node biopsy in breast cancer. The success rate of radioguidance in localising the sentinel lymph node in breast cancer surgery is about 97% in institutions where a high number of procedures are performed, and the success rate of lymphoscintigraphy in sentinel node detection is about 100%. The sentinel lymph node should be processed for intraoperative frozen section examination in its entirety, based on conventional histopathology and, when necessary, immune staining with anti-cytokeratin antibody. Nowadays, lymphoscintigraphy is a useful procedure in patients with different clinical evidence of breast cancer.

  6. Littered cigarette butts as a source of nicotine in urban waters

    Science.gov (United States)

    Roder Green, Amy L.; Putschew, Anke; Nehls, Thomas

    2014-11-01

    The effect of nicotine from littered cigarette butts on the quality of urban water resources has yet to be investigated. This two-part study addresses the spatial variation, seasonal dynamics and average residence time of littered cigarette butts in public space, as well as the release of nicotine from cigarette butts to run-off in urban areas during its residence time. Thereby, we tested two typical situations: release to standing water in a puddle and release during alternating rainfall and drying. The study took place in Berlin, Germany, a city which completely relies on its own water resources to meet its drinking water demand. Nine typical sites located in a central district, each divided into 20 plots were studied during five sampling periods between May 2012 and February 2013. The nicotine release from standardized cigarette butts prepared with a smoking machine was examined in batch and rainfall experiments. Littered cigarette butts are unevenly distributed among both sites and plots. The average butt concentration was 2.7 m-2 (SD = 0.6 m-2, N = 862); the maximum plot concentration was 48.8 butts m-2. This heterogeneity is caused by preferential littering (gastronomy, entrances, bus stops), redistribution processes such as litter removal (gastronomy, shop owners), and the increased accumulation in plots protected from mechanized street sweeping (tree pits, bicycle stands). No significant seasonal variation of cigarette butt accumulation was observed. On average, cigarette butt accumulation is characterized by a 6 days cadence due to the rhythm and effectiveness of street sweeping (mean weekly butt accumulation rate = 0.18 m-2 d-1; SD = 0.15 m-1). Once the butt is exposed to standing water, elution of nicotine occurs rapidly. Standardized butts released 7.3 mg g-1 nicotine in a batch experiment (equivalent to 2.5 mg L-1), 50% of which occurred within the first 27 min. In the rainfall experiment, the cumulative nicotine release from fifteen consecutive

  7. Sutter Buttes-the lone volcano in California's Great Valley

    Science.gov (United States)

    Hausback, Brain P.; Muffler, L.J. Patrick; Clynne, Michael A.

    2011-01-01

    The volcanic spires of the Sutter Buttes tower 2,000 feet above the farms and fields of California's Great Valley, just 50 miles north-northwest of Sacramento and 11 miles northwest of Yuba City. The only volcano within the valley, the Buttes consist of a central core of volcanic domes surrounded by a large apron of fragmental volcanic debris. Eruptions at the Sutter Buttes occurred in early Pleistocene time, 1.6 to 1.4 million years ago. The Sutter Buttes are not part of the Cascade Range of volcanoes to the north, but instead are related to the volcanoes in the Coast Ranges to the west in the vicinity of Clear Lake, Napa Valley, and Sonoma Valley.

  8. 77 FR 12106 - Kapka Butte Sno-Park Construction

    Science.gov (United States)

    2012-02-28

    ... DEPARTMENT OF TRANSPORTATION Federal Highway Administration Kapka Butte Sno-Park Construction... Construction project. SUMMARY: The FHWA is issuing this notice to advise the public that the FHWA is officially designated as the Joint-Lead Agency pursuant to 23 U.S.C. 139(c)(1) for the Kapka Butte Sno-Park Construction...

  9. Bali Cattle Carcass Characteristic of Different Butt Shape Condition

    Science.gov (United States)

    Hafid, H.; Nuraini; Inderawati; Kurniawan, W.

    2018-02-01

    Carcass was main product on cattle slaughtering which contain beef for human consumption and it has high nutritional and economical value. Carcass production on cattle has been influenced by several factors, such as cattle breed, feed, and body conformation. Cattle Butt Shape was one of part cattle body conformation which allegedly has have positive correlation on produced carcass. This research was aimed to evaluate Butt Shape condition influenced on Bali cattle carcass characteristic. The research was using Bali cattle which slaughter in Kendari Slaughtering House (Rumah Potong Hewan/RPH - Kendari). The observation includes weighing, and measuring parts of carcass was conducted on 60 heads of Halal process slaughtered Bali cattle which traditionally maintained. The research parameters were carcass productivity parameters i.e: slaughtering weight, carcass weight and length, leg length and circumstances. Obtained data were analyzed using Complete Randomized Design and post hoc analyzed using Least Significant Different if have any influence. The research result showed that cattle Butt Shape condition have significant (pBali cattle carcass productivity parameters. Butt shape with B category was result the best carcass productivity compare the others, while C category was better than D. It can be concluded that body and carcass weight were linearly influenced by cattle butt shape.

  10. Geographic patterns of cigarette butt waste in the urban environment.

    Science.gov (United States)

    Marah, Maacah; Novotny, Thomas E

    2011-05-01

    This reports the initial phase of a study to quantify the spatial pattern of cigarette butt waste in an urban environment. Geographic Information Systems (GIS) was used to create a weighted overlay analysis model which was then applied to the locations of businesses where cigarettes are sold or are likely to be consumed and venues where higher concentrations of butts may be deposited. The model's utility was tested using a small-scale litter audit in three zip codes of San Diego, California. We found that cigarette butt waste is highly concentrated around businesses where cigarettes are sold or consumed. The mean number of butts for predicted high waste sites was 38.1 (SD 18.87), for predicted low waste sites mean 4.8 (SD 5.9), psales and consumption. A GIS and weighted overlay model may be a useful tool in predicting urban locations of greater and lesser amounts of cigarette butt waste. These data can in turn be used to develop economic cost studies and plan mitigation strategies in urban communities.

  11. [Even cigarette butts can impact environment and health: preliminary considerations].

    Science.gov (United States)

    Martino, Gianrocco; Gorini, Giuseppe; Chellini, Elisabetta

    2013-01-01

    In Italy, every year about 72 billion of cigarette butts are thrown away in the environment. Cigarette butts represent 50% of the wastes of urban areas (parks, roads) in the world, and 40% of Mediterranean Sea wastes. In particular, total polluting load is constituted of 1,872 Bq millions of Polonium-210, assuming 75 mBq per cigarette butt, and 1,800 tons of volatile organic compounds. As a matter of fact, according to several surveys, cigarette butts are considered by smokers and non-smokers as a common and acceptable waste in the environment. In 2008, European Union issued a Directive on wastes considering the «extended producer responsibility» (i.e., every industry is liable for costs of collection, transport and disposal of its own products). In October 2012, the Italian Parliament proposed a bill that classifies cigarette butts as special wastes in the frame of this responsibility. It could be interesting in the future to follow the legislative process of that bill in the Italian Parliament in order to show how strong it will be supported.

  12. Geology of Gable Mountain-Gable Butte Area

    International Nuclear Information System (INIS)

    Fecht, K.R.

    1978-09-01

    Gable Mountain and Gable Butte are two ridges which form the only extensive outcrops of the Columbia River Basalt Group in the central portion of the Pasco Basin. The Saddle Mountains Basalt and two interbedded sedimentary units of the Ellensburg Formation crop out on the ridges. These include, from oldest to youngest, the Asotin Member (oldest), Esquatzel Member, Selah Interbed, Pomona Member, Rattlesnake Ridge Interbed, and Elephant Mountain Member (youngest). A fluvial plain composed of sediments from the Ringold and Hanford (informal) formations surrounds these ridges. The structure of Gable Mountain and Gable Butte is dominated by an east-west-trending major fold and northwest-southeast-trending parasitic folds. Two faults associated with the uplift of these structures were mapped on Gable Mountain. The geomorphic expression of the Gable Mountain-Gable Butte area resulted from the comlex folding and subsequent scouring by post-basalt fluvial systems

  13. SENTINEL EVENTS

    Directory of Open Access Journals (Sweden)

    Andrej Robida

    2004-09-01

    Full Text Available Background. The Objective of the article is a two year statistics on sentinel events in hospitals. Results of a survey on sentinel events and the attitude of hospital leaders and staff are also included. Some recommendations regarding patient safety and the handling of sentinel events are given.Methods. In March 2002 the Ministry of Health introduce a voluntary reporting system on sentinel events in Slovenian hospitals. Sentinel events were analyzed according to the place the event, its content, and root causes. To show results of the first year, a conference for hospital directors and medical directors was organized. A survey was conducted among the participants with the purpose of gathering information about their view on sentinel events. One hundred questionnaires were distributed.Results. Sentinel events. There were 14 reports of sentinel events in the first year and 7 in the second. In 4 cases reports were received only after written reminders were sent to the responsible persons, in one case no reports were obtained. There were 14 deaths, 5 of these were in-hospital suicides, 6 were due to an adverse event, 3 were unexplained. Events not leading to death were a suicide attempt, a wrong side surgery, a paraplegia after spinal anaesthesia, a fall with a femoral neck fracture, a damage of the spleen in the event of pleural space drainage, inadvertent embolization with absolute alcohol into a femoral artery and a physical attack on a physician by a patient. Analysis of root causes of sentinel events showed that in most cases processes were inadequate.Survey. One quarter of those surveyed did not know about the sentinel events reporting system. 16% were having actual problems when reporting events and 47% beleived that there was an attempt to blame individuals. Obstacles in reporting events openly were fear of consequences, moral shame, fear of public disclosure of names of participants in the event and exposure in mass media. The majority of

  14. Butt-welding technology for double walled Polyethylene pipe

    International Nuclear Information System (INIS)

    Lee, Bo-Young; Kim, Jae-Seong; Lee, Sang-Yul; Kim, Yeong K.

    2012-01-01

    Highlights: ► We developed a butt welding apparatus for doubled walled Polyethylene pipe. ► We design the welding process by analyzing thermal behaviors of the material. ► We performed the welding and tested the welded structural performances. ► We also applied the same technology to PVC pipes. ► We verified the butt welding was successful and effective for the pipes with irregular sections. -- Abstract: In this study, mechanical analyses of a butt welding technology for joining Polyethylene pipe are presented. The pipe had unique structure with double wall, and its section topology was not flat. For an effective repair of leakage and replacements of the pipe, the butt welding technology was developed and tested. For the material characterizations, thermodynamic analyses such as thermal gravimetric analysis and differential scanning calorimetry were performed. Based on the test results, the process temperature and time were determined to ensure safe joining of the pipes using a hot plate apparatus. The welding process was carefully monitored by measuring the temperature. Then, the joined pipes were tested by various methods to evaluate the quality. The analyses results showed the detail process mechanism during the joining process, and the test results demonstrated the successful application of the technology to the sewage pipe repairs.

  15. Sentinel Mining

    DEFF Research Database (Denmark)

    Middelfart, Morten

    business users about potential changes to Key Performance Indicators (KPIs) and thereby facilitate corrective action before such a change becomes a reality. Specifically, sentinels are rule relationships at the schema level in a multidimensional data cube. These relationships represent changes over time...... in certain measures that are followed by a change in a user defined critical measure, typically a KPI. An important property of a sentinel is bi-directionality, which means that the change relationship holds in the complement direction, since a sentinel with the bi-directional property has a higher chance...

  16. Gap Width Study and Fixture Design in Laser Butt-Welding

    DEFF Research Database (Denmark)

    Gong, Hui; Olsen, Flemming Ove

    .5-2.0 m/min, the laser power : 2 and 2.6 kW and the focal point position : 0 and -1.2 mm. Quality of all the butt welds are destructively tested according to ISO 13919-1.Influences of the variable process parameters to the maximum allowable gap width are observed as (1) the maximum gap width is inversely......This paper discusses some practical consideration for design of a mechanical fixture, which enables to accurately measure the width of a gap between two stainless steel workpieces and to steadfastly clamp the workpieces for butt-welding with a high power CO2 laser.With such a fixture, a series...... of butt-welding experiment is successfully carried out in order to find the maximum allowable gap width in laser butt-welding. The gap width study (GWS) is performed on the material of SST of W1.4401 (AISI 316) under various welding conditions, which are the gap width : 0.00-0.50 mm, the welding speed : 0...

  17. Equipment for Preparing Pipeline Position Butts for Welding

    Directory of Open Access Journals (Sweden)

    Lobanov L.M.

    2015-09-01

    Full Text Available The results of developments of the Ye.O.Paton Electric Welding Institute and its specialized departments on the designing national equipment models for preparation during the assembly the edges and butt ends of pipeline position butts with the diameter from 14 up to 159 mm, repair and modernization of power engineering objects, including the power units of nuclear and heat electric stations, in chemical and machine building, at enterprises of oil-gas complex and other branches of industry are presented.

  18. Sentinel node concept in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kiricuta, I.C. [St. Vincenz-Hospital, Limburg (Germany). Inst. for Radiation Oncology

    2000-07-01

    Background/purpose: It seems that there exists a specific lymph node center called sentinel node (SN) which appears to be the primary site of metastases. The sentinel node concept (SNC) is fundamentally based on the orderly progression of tumor cells within the lymphatic system. It is the most important new concept in surgical and radiation oncology. The purpose is to present the biological significance, the diagnostic and clinical basis of the sentinel node concept in breast cancer patients. Material and methods: Lymphoscintigraphy and gamma probe biopsy is necessary to show predictable lymph flow to the regional sentinel node, to multiple sentinel nodes or unpredictable lymph flow to extra-regional sentinel nodes and for performing sentinel node procedure. The standard protocol for the evaluation of the sentinel node metastases consists of extensive histopathological investigation including step Hematoxylin and Eosin (H and E) stained sections and immunohistochemistry. Results: A high rate of success of the identification of the sentinel node for breast cancer was reported. The presence or absence of metastasis in this node is a very accurate predictor of overall nodal status. The temptation to examine the sentinel node with the greatest possible degree of accuracy highlights one of the major problems related to sentinel node biopsy. The success of the sentinel node procedure depends primarily on the adequate functional capacity necessary for sufficient uptake to ensure the accurate identification. In negative sentinel-node patients a complete axillary lymph node dissection is avoidable. In sentinel-node positive patients and clinically negative patients a postoperative radiotherapy would permit an adequate tumor control. The last 2-procedures permit a low morbidity. In the actual TNM classification it was recently introduced a definition of a 'pN0' patient based on sentinel node biopsy. New target volumes are defined for adjuvant radiotherapy or

  19. Land science with Sentinel-2 and Sentinel-3 data series synergy

    Science.gov (United States)

    Moreno, Jose; Guanter, Luis; Alonso, Luis; Gomez, Luis; Amoros, Julia; Camps, Gustavo; Delegido, Jesus

    2010-05-01

    Although the GMES/Sentinel satellite series were primarily designed to provide observations for operational services and routine applications, there is a growing interest in the scientific community towards the usage of Sentinel data for more advanced and innovative science. Apart from the improved spatial and spectral capabilities, the availability of consistent time series covering a period of over 20 years opens possibilities never explored before, such as systematic data assimilation approaches exploiting the time-series concept, or the incorporation in the modelling approaches of processes covering time scales from weeks to decades. Sentinel-3 will provide continuity to current ENVISAT MERIS/AATSR capabilities. The results already derived from MERIS/AATRS will be more systematically exploited by using OLCI in synergy with SLST. Particularly innovative is the case of Sentinel-2, which is specifically designed for land applications. Built on a constellation of two satellites operating simultaneously to provide 5 days geometric revisit time, the Sentinel-2 system will providing global and systematic acquisitions with high spatial resolution and with a high revisit time tailored towards the needs of land monitoring. Apart from providing continuity to Landsat and SPOT time series, the Sentinel-2 Multi-Spectral Instrument (MSI) incorporates new narrow bands around the red-edge for improved retrievals of biophysical parameters. The limitations imposed by the need of a proper cloud screening and atmospheric corrections have represented a serious constraint in the past for optical data. The fact that both Sentinel-2 and 3 have dedicated bands to allow such needed corrections for optical data represents an important step towards a proper exploitation, guarantying consistent time series showing actual variability in land surface conditions without the artefacts introduced by the atmosphere. Expected operational products (such as Land Cover maps, Leaf Area Index

  20. 75 FR 53714 - Stainless Steel Butt-Weld Pipe Fittings From Japan, Korea, and Taiwan

    Science.gov (United States)

    2010-09-01

    ...)] Stainless Steel Butt-Weld Pipe Fittings From Japan, Korea, and Taiwan AGENCY: United States International... stainless steel butt-weld pipe fittings from Japan, Korea, and Taiwan. SUMMARY: The Commission hereby gives... butt-weld pipe fittings from Japan, Korea, and Taiwan would be likely to lead to continuation or...

  1. Regulating the disposal of cigarette butts as toxic hazardous waste.

    Science.gov (United States)

    Barnes, Richard L

    2011-05-01

    The trillions of cigarette butts generated each year throughout the world pose a significant challenge for disposal regulations, primarily because there are millions of points of disposal, along with the necessity to segregate, collect and dispose of the butts in a safe manner, and cigarette butts are toxic, hazardous waste. There are some hazardous waste laws, such as those covering used tyres and automobile batteries, in which the retailer is responsible for the proper disposal of the waste, but most post-consumer waste disposal is the responsibility of the consumer. Concepts such as extended producer responsibility (EPR) are being used for some post-consumer waste to pass the responsibility and cost for recycling or disposal to the manufacturer of the product. In total, 32 states in the US have passed EPR laws covering auto switches, batteries, carpet, cell phones, electronics, fluorescent lighting, mercury thermostats, paint and pesticide containers, and these could be models for cigarette waste legislation. A broader concept of producer stewardship includes EPR, but adds the consumer and the retailer into the regulation. The State of Maine considered a comprehensive product stewardship law in 2010 that is a much better model than EPR. By using either EPR or the Maine model, the tobacco industry will be required to cover the cost of collecting and disposing of cigarette butt waste. Additional requirements included in the Maine model are needed for consumers and businesses to complete the network that will be necessary to maximise the segregation and collection of cigarette butts to protect the environment.

  2. Sentinel node concept in breast cancer

    International Nuclear Information System (INIS)

    Kiricuta, I.C.

    2000-01-01

    Background/purpose: It seems that there exists a specific lymph node center called sentinel node (SN) which appears to be the primary site of metastases. The sentinel node concept (SNC) is fundamentally based on the orderly progression of tumor cells within the lymphatic system. It is the most important new concept in surgical and radiation oncology. The purpose is to present the biological significance, the diagnostic and clinical basis of the sentinel node concept in breast cancer patients. Material and methods: Lymphoscintigraphy and gamma probe biopsy is necessary to show predictable lymph flow to the regional sentinel node, to multiple sentinel nodes or unpredictable lymph flow to extra-regional sentinel nodes and for performing sentinel node procedure. The standard protocol for the evaluation of the sentinel node metastases consists of extensive histopathological investigation including step Hematoxylin and Eosin (H and E) stained sections and immunohistochemistry. Results: A high rate of success of the identification of the sentinel node for breast cancer was reported. The presence or absence of metastasis in this node is a very accurate predictor of overall nodal status. The temptation to examine the sentinel node with the greatest possible degree of accuracy highlights one of the major problems related to sentinel node biopsy. The success of the sentinel node procedure depends primarily on the adequate functional capacity necessary for sufficient uptake to ensure the accurate identification. In negative sentinel-node patients a complete axillary lymph node dissection is avoidable. In sentinel-node positive patients and clinically negative patients a postoperative radiotherapy would permit an adequate tumor control. The last 2-procedures permit a low morbidity. In the actual TNM classification it was recently introduced a definition of a 'pN0' patient based on sentinel node biopsy. New target volumes are defined for adjuvant radiotherapy or lymphatic basins

  3. 77 FR 42697 - Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines: Continuation...

    Science.gov (United States)

    2012-07-20

    ...] Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines: Continuation of... from Italy, Malaysia, and the Philippines.\\2\\ \\1\\ See Antidumping Duty Orders: Stainless Steel Butt...), titled Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines (Investigation...

  4. Sentinel-3 For Land Applications

    Science.gov (United States)

    Goryl, Philippe; Gobron, Nadine; Mecklenburg, Susanne; Donlon, Craig; Bouvet, Marc; Buongiorno, Alessandra; Wilson, Hilary

    2016-07-01

    The Copernicus Programme, being Europe's Earth Observation and Monitoring Programme led by the European Union, aims to provide, on a sustainable basis, reliable and timely services related to environmental and security issues. The Sentinel-3 mission forms part of the Copernicus Space Component. Its main objectives, building on the heritage and experience of the European Space Agency's (ESA) ERS and ENVISAT missions, are to measure sea-surface topography, sea- and land-surface temperature and ocean- and land-surface colour in support of ocean forecasting systems, and for environmental and climate monitoring. The series of Sentinel-3 satellites will ensure global, frequent and near-real time ocean, ice and land monitoring, with the provision of observation data in a routine, long-term (up to 20 years of operations) and continuous fashion, with a consistent quality and a high level of reliability and availability. The launch of Sentinel-3 was successful last February 2016. The Sentinel-3 missions are jointly operated by ESA and EUMETSAT. ESA will be responsible for the operations, maintenance and evolution of the Sentinel-3 ground segment on land related products and EUMETSAT on the marine products and the satellite monitoring and control. All facilities supporting the Sentinel-3 operations are in place. The Sentinel-3 ground segment systematically acquires, processes and distributes a set of pre-defined core data products to the users. For a detailed description of the core data products please see https://earth.esa.int/web/sentinel/missions/sentinel-3/data-products. On request from the European Commission, ESA and EUMETSAT are presently assessing the possibility to include further core data products, in particular on aerosol optical depth, fire monitoring and synergistic products over land. This paper will provide an update on the status of the mission operations after the initial months in orbit and provide in particular an overview on the status of the Sentinel-3

  5. Radio and television use in Butte County, California: application to fire prevention

    Science.gov (United States)

    William S. Folkman

    1975-01-01

    A sample of Butte County residents were interviewed about their radio and television use habits. Their responses were analyzed in terms of demographic, social, and economic characteristics. The findings can be used in developing more effective fire prevention programs. Most people in Butte County listen to the radio or watch television but they differ widely in the way...

  6. Sentinel-2B image quality commissioning phase results and Sentinel2 constellation performances

    Science.gov (United States)

    Languille, F.; Gaudel, A.; Vidal, B.; Binet, R.; Poulain, V.; Trémas, T.

    2017-09-01

    In the frame of the Copernicus program of the European Commission, Sentinel-2 is a constellation of 2 satellites on a polar sun-synchronous orbit with a revisit time of 5 days (with both satellites), a high field of view - 290km, 13 spectral bands in visible and shortwave infrared, and high spatial resolution - 10m, 20m and 60m. The Sentinel-2 mission offers a global coverage over terrestrial surfaces. The satellites acquire systematically terrestrial surfaces under the same viewing conditions in order to have temporal images stacks. The first satellite was launched in June 2015 and the second in March 2017. In cooperation with the European Space Agency (ESA), the French space agency (CNES) is in charge of the image quality of the project, and so ensured the CAL/VAL commissioning phase during the months following the launch. This cooperation is also extended to routine phase as CNES supports European Space Research Institute (ESRIN) and the Sentinel-2 Mission performance Centre (MPC) for validation in geometric and radiometric image quality aspects, and in Sentinel-2 Global Reference Image (GRI) geolocation performance assessment. This paper points on geometric image quality on Sentinel-2B commissioning phase. It relates to the methods and the performances obtained, as well as the comparison between S2A and S2B. This deals with geolocation and multispectral registration. A small focus is also done on the Sentinel-2 GRI which is a set of S2A images at 10m resolution covering the whole world with a good and consistent geolocation. This ground reference leads to ensure an accurate multi-temporal registration -on refined Sentinel-2 products over GRI- which is also presented in this paper.

  7. Copernicus POD Service: Ready for Sentinel-3

    Science.gov (United States)

    Peter, H.; Fernández, J.; Escobar, D.; Féménias, P.; Flohrer, C.; Otten, M.

    2015-12-01

    The Copernicus POD Service is part of the Copernicus PDGS Ground Segment of the Sentinel missions. A GMV-led consortium is operating the Copernicus POD Service being in charge of generating precise orbital products and auxiliary data files for their use as part of the processing chains of the respective Sentinel PDGS. The Sentinel-1, -2 & -3 missions have different but very demanding requirements in terms of orbital accuracy and timeliness. Orbital products in Near Real Time (latency: 30 min), Short Time Critical (1.5 days) and Non-time Critical (20-30 days) are required. The accuracy requirements are very challenging, targeting 5 cm in 3D for Sentinel-1 and 2-3 cm in radial direction for Sentinel-3. Sentinel-3A carries, in addition to a GPS receiver a laser retro reflector and a DORIS receiver. On the one hand, the three different techniques GPS, SLR and DORIS make POD more complex but, on the other hand, it is very helpful to have independent techniques available for validation of the orbit results. The successful POD processing for Sentinel-1A is a good preparation for Sentinel-3A due to the similar demanding orbit accuracy requirements. The Copernicus POD Service is ready for Sentinel-3A and the service will process GPS and SLR data routinely and has the capacity to process DORIS in NTC and reprocessing campaigns. The three independent orbit determination techniques on Sentinel-3 offer big potential for scientific exploitation. Carrying all three techniques together makes the satellite, e.g., very useful for combining all the techniques on observation level as it could only be done for Jason-2 until now. The Sentinel POD Quality Working Group strongly supporting the CPOD Service delivers additional orbit solutions to validate the CPOD results independently. The recommendations from this body guarantee that the CPOD Service is updated following state-of-the-art algorithms, models and conventions. The QWG also focuses on the scientific exploitation of the

  8. 77 FR 14002 - Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines: Final Results...

    Science.gov (United States)

    2012-03-08

    ...] Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines: Final Results of the... Duty Orders on Stainless Steel Butt-Weld Pipe Fittings from Italy, Malaysia, and the Philippines'' from... Commerce (the Department) initiated sunset reviews of the antidumping duty orders on stainless steel butt...

  9. Dormaier and Chester Butte 2007 Follow-up Habitat Evaluation Procedures Report.

    Energy Technology Data Exchange (ETDEWEB)

    Ashley, Paul R.

    2008-01-01

    Follow-up habitat evaluation procedures (HEP) analyses were conducted on the Dormaier and Chester Butte wildlife mitigation sites in April 2007 to determine the number of additional habitat units to credit Bonneville Power Administration (BPA) for providing funds to enhance, and maintain the project sites as partial mitigation for habitat losses associated with construction of Grand Coulee Dam. The Dormaier follow-up HEP survey generated 482.92 habitat units (HU) or 1.51 HUs per acre for an increase of 34.92 HUs over baseline credits. Likewise, 2,949.06 HUs (1.45 HUs/acre) were generated from the Chester Butte follow-up HEP analysis for an increase of 1,511.29 habitat units above baseline survey results. Combined, BPA will be credited with an additional 1,546.21 follow-up habitat units from the Dormaier and Chester Butte parcels.

  10. A study of fatigue life distribution of butt-welded joints

    International Nuclear Information System (INIS)

    Sakai, Tatsuo; Fujitani, Keizo; Kikuchi, Toshiro; Tanaka, Takao.

    1981-01-01

    Various kinds of welded joints are being used in many structures such as ships, bridges and constructions. It is important in reliability analysis of such structures to clarify the statistical fatigue property of the welded joints. In this study, fatigue tests were carried out on the butt-welded joints of SM50A steel and a theoretical interpretation on the fatigue life distribution was attempted, assuming that a butt-welded joint is composed of a number of sliced specimens with different fatigue strengths. Main results obtained are summarized as follows; (1) The median crack initiation life of the butt-welded joint specimens coincided with that of the sliced specimens, when the crack initiation was defined by a 0.2 mm crack in the sliced specimens or the equivalent state of stress intensity factor in the joint specimens. (2) The distribution of crack initiation lives of the butt-welded joints can be theoretically derived by combining the concept of extreme distribution and the distribution model on the number of fatigue cracks. The theoretical distribution of crack initiation lives of the joints is in good agreement with the general trend of the experimental results. (3) If the distribution of crack initiation lives and the crack growth law are given experimentally, one can obtain analytically the distribution of final fatigue lives. The fatigue life distribution of the sliced specimens can be explained by the theory established in this study. (author)

  11. The Sentinel 4 focal plane subsystem

    Science.gov (United States)

    Hohn, Rüdiger; Skegg, Michael P.; Hermsen, Markus; Hinger, Jürgen; Williges, Christian; Reulke, Ralf

    2017-09-01

    The Sentinel 4 instrument is an imaging spectrometer, developed by Airbus under ESA contract in the frame of the joint European Union (EU)/ESA COPERNICUS program with the objective of monitoring trace gas concentrations. Sentinel 4 will provide accurate measurements of key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, formaldehyde, as well as aerosol and cloud properties. Sentinel 4 is unique in being the first geostationary UVN mission. The SENTINEL 4 space segment will be integrated on EUMETSAT's Meteosat Third Generation Sounder satellite (MTG-S). Sentinel 4 will provide coverage of Europe and adjacent regions. The Sentinel 4 instrument comprises as a major element two Focal Plane Subsystems (FPS) covering the wavelength ranges 305 nm to 500 nm (UVVIS) and 750 nm to 775 nm (NIR) respectively. The paper describes the Focal Plane Subsystems, comprising the detectors, the optical bench and the control electronics. Further the design and development approach will be presented as well as first measurement results of FPS Qualification Model.

  12. 76 FR 67473 - Stainless Steel Butt-Weld Pipe Fittings from Italy, Malaysia, and The Philippines; Institution of...

    Science.gov (United States)

    2011-11-01

    ... Concerning the Antidumping Duty Orders on Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and... stainless steel butt-weld pipe fittings from Italy, Malaysia, and the Philippines would be likely to lead to... antidumping duty orders on imports of stainless steel butt-weld pipe fittings from Italy, Malaysia, and the...

  13. GAP WIDTH STUDY IN LASER BUTT-WELDING

    DEFF Research Database (Denmark)

    Gong, Hui; Olsen, Flemming Ove

    power : 2 and 2.6 kW and the focal point position : 0 and -1.2 mm. Quality of all the butt welds are destructively tested according to ISO 13919-1.Influences of the variable process parameters to the maximum allowable gap width are observed as (1) the maximum gap width is inversely related......In this paper the maximum allowable gap width in laser butt-welding is intensively studied. The gap width study (GWS) is performed on the material of SST of W1.4401 (AISI 316) under various welding conditions, which are the gap width : 0.00-0.50 mm, the welding speed : 0.5-2.0 m/min, the laser...... to the welding speed, (2) the larger laser power leads to the bigger maximum allowable gap width and (3) the focal point position has very little influence on the maximum gap width....

  14. Sentinels for snow science

    Science.gov (United States)

    Gascoin, S.; Grizonnet, M.; Baba, W. M.; Hagolle, O.; Fayad, A.; Mermoz, S.; Kinnard, C.; Fatima, K.; Jarlan, L.; Hanich, L.

    2017-12-01

    Current spaceborne sensors do not allow retrieving the snow water equivalent in mountain regions, "the most important unsolved problem in snow hydrology" (Dozier, 2016). While the NASA is operating an airborne mission to survey the SWE in the western USA, elsewhere, however, snow scientists and water managers do not have access to routine SWE measurements at the scale of a mountain range. In this presentation we suggest that the advent of the Copernicus Earth Observation programme opens new perspectives to address this issue in mountain regions worldwide. The Sentinel-2 mission will provide global-scale multispectral observations at 20 m resolution every 5-days (cloud permitting). The Sentinel-1 mission is already imaging the global land surface with a C-band radar at 10 m resolution every 6 days. These observations are unprecedented in terms of spatial and temporal resolution. However, the nature of the observation (radiometry, wavelength) is in the continuity of previous and ongoing missions. As a result, it is relatively straightforward to re-use algorithms that were developed by the remote sensing community over the last decades. For instance, Sentinel-2 data can be used to derive maps of the snow cover extent from the normalized difference snow index, which was initially proposed for Landsat. In addition, the 5-days repeat cycle allows the application of gap-filling algorithms, which were developed for MODIS based on the temporal dimension. The Sentinel-1 data can be used to detect the wet snow cover and track melting areas as proposed for ERS in the early 1990's. Eventually, we show an example where Sentinel-2-like data improved the simulation of the SWE in the data-scarce region of the High Atlas in Morocco through assimilation in a distributed snowpack model. We encourage snow scientists to embrace Sentinel-1 and Sentinel-2 data to enhance our knowledge on the snow cover dynamics in mountain regions.

  15. Aluminum 6060-T6 friction stir welded butt joints: fatigue resistance with different tools and feed rates

    International Nuclear Information System (INIS)

    Baragetti, S.; D'Urso, G.

    2014-01-01

    The fatigue behavior of AA6060-T6 friction stir welded butt joints was investigated. The joints were produced by using both a standard and a threaded tri-flute cylindrical-tool with flat shoulder. The friction stir welding process was carried out using different feed rates. Preliminary tensile tests, micrograph analyses and hardness profile measurements across the welds were carried out. Welded and unwelded fatigue samples were tested under axial loading (R = 0.1) with upper limits of 10 4 and 10 5 cycles, using threaded and unthreaded (standard) tools at different feed rates. The best tensile and fatigue performance was obtained using the standard tool at low feed rate.

  16. 75 FR 76025 - Stainless Steel Butt-Weld Pipe Fittings From Japan, Korea, and Taiwan

    Science.gov (United States)

    2010-12-07

    ... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 731-TA-376 and 563-564 (Third Review)] Stainless Steel Butt-Weld Pipe Fittings From Japan, Korea, and Taiwan AGENCY: United States International... steel butt-weld pipe fittings from Japan, Korea, and Taiwan would be likely to lead to continuation or...

  17. Discovering Sentinel Rules for Business Intelligence

    Science.gov (United States)

    Middelfart, Morten; Pedersen, Torben Bach

    This paper proposes the concept of sentinel rules for multi-dimensional data that warns users when measure data concerning the external environment changes. For instance, a surge in negative blogging about a company could trigger a sentinel rule warning that revenue will decrease within two months, so a new course of action can be taken. Hereby, we expand the window of opportunity for organizations and facilitate successful navigation even though the world behaves chaotically. Since sentinel rules are at the schema level as opposed to the data level, and operate on data changes as opposed to absolute data values, we are able to discover strong and useful sentinel rules that would otherwise be hidden when using sequential pattern mining or correlation techniques. We present a method for sentinel rule discovery and an implementation of this method that scales linearly on large data volumes.

  18. Comparison of Water Years 2004-05 and Historical Water-Quality Data, Upper Gunnison River Basin, Colorado

    Science.gov (United States)

    Spahr, Norman E.; Hartle, David M.; Diaz, Paul

    2008-01-01

    Population growth and changes in land use have the potential to affect water quality and quantity in the upper Gunnison River Basin. In 1995, the U.S. Geological Survey (USGS), in cooperation with the Bureau of Land Management, City of Gunnison, Colorado River Water Conservation District, Crested Butte South Metropolitan District, Gunnison County, Hinsdale County, Mount Crested Butte Water and Sanitation District, National Park Service, Town of Crested Butte, Upper Gunnison River Water Conservancy District, and Western State College, established a water-quality monitoring program in the upper Gunnison River Basin to characterize current water-quality conditions and to assess the effects of increased urban development and other land-use changes on water quality. The monitoring network has evolved into two groups of stations - stations that are considered long term and stations that are considered rotational. The long-term stations are monitored to assist in defining temporal changes in water quality (how conditions may change over time). The rotational stations are monitored to assist in the spatial definition of water-quality conditions (how conditions differ throughout the basin) and to address local and short-term concerns. Some stations in the rotational group were changed beginning in water year 2007. Annual summaries of the water-quality data from the monitoring network provide a point of reference for discussions regarding water-quality monitoring in the upper Gunnison River Basin. This summary includes data collected during water years 2004 and 2005. The introduction provides a map of the sampling sites, definitions of terms, and a one-page summary of selected water-quality conditions at the network stations. The remainder of the summary is organized around the data collected at individual stations. Data collected during water years 2004 and 2005 are compared to historical data, State water-quality standards, and Federal water-quality guidelines. Data were

  19. Independent System Calibration of Sentinel-1B

    Directory of Open Access Journals (Sweden)

    Marco Schwerdt

    2017-05-01

    Full Text Available Sentinel-1B is the second of two C-Band Synthetic Aperture Radar (SAR satellites of the Sentinel-1 mission, launched in April 2016—two years after the launch of the first satellite, Sentinel-1A. In addition to the commissioning of Sentinel-1B executed by the European Space Agency (ESA, an independent system calibration was performed by the German Aerospace Center (DLR on behalf of ESA. Based on an efficient calibration strategy and the different calibration procedures already developed and applied for Sentinel-1A, extensive measurement campaigns were executed by initializing and aligning DLR’s reference targets deployed on the ground. This paper describes the different activities performed by DLR during the Sentinel-1B commissioning phase and presents the results derived from the analysis and the evaluation of a multitude of data takes and measurements.

  20. Numerical estimation of temperature field in a laser welded butt joint made of dissimilar materials

    Directory of Open Access Journals (Sweden)

    Saternus Zbigniew

    2018-01-01

    Full Text Available The paper concerns numerical analysis of thermal phenomena occurring in the butt welding of two different materials by a laser beam welding. The temperature distribution for the welded butt-joint is obtained on the basis of numerical simulations performed in the ABAQUS program. Numerical analysis takes into account the thermophysical properties of welded plate made of two different materials. Temperature distribution in analysed joints is obtained on the basis of numerical simulation in Abaqus/Standard solver, which allowed the determination of the geometry of laser welded butt-joint.

  1. SENTINEL-1 and SENTINEL-2 Data Fusion for Wetlands Mapping: Balikdami, Turkey

    Science.gov (United States)

    Kaplan, G.; Avdan, U.

    2018-04-01

    Wetlands provide a number of environmental and socio-economic benefits such as their ability to store floodwaters and improve water quality, providing habitats for wildlife and supporting biodiversity, as well as aesthetic values. Remote sensing technology has proven to be a useful and frequent application in monitoring and mapping wetlands. Combining optical and microwave satellite data can help with mapping and monitoring the biophysical characteristics of wetlands and wetlands` vegetation. Also, fusing radar and optical remote sensing data can increase the wetland classification accuracy. In this paper, data from the fine spatial resolution optical satellite, Sentinel-2 and the Synthetic Aperture Radar Satellite, Sentinel-1, were fused for mapping wetlands. Both Sentinel-1 and Sentinel-2 images were pre-processed. After the pre-processing, vegetation indices were calculated using the Sentinel-2 bands and the results were included in the fusion data set. For the classification of the fused data, three different classification approaches were used and compared. The results showed significant improvement in the wetland classification using both multispectral and microwave data. Also, the presence of the red edge bands and the vegetation indices used in the data set showed significant improvement in the discrimination between wetlands and other vegetated areas. The statistical results of the fusion of the optical and radar data showed high wetland mapping accuracy, showing an overall classification accuracy of approximately 90 % in the object-based classification method. For future research, we recommend multi-temporal image use, terrain data collection, as well as a comparison of the used method with the traditional image fusion techniques.

  2. 78 FR 21582 - Revisions to the California State Implementation Plan, Butte County Air Quality Management...

    Science.gov (United States)

    2013-04-11

    ... the California State Implementation Plan, Butte County Air Quality Management District and Sacramento Metropolitan Air Quality Management District AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule. SUMMARY: EPA is proposing to approve revisions to the Butte County Air Quality Management...

  3. The hidden sentinel node in breast cancer

    International Nuclear Information System (INIS)

    Tanis, P.J.; Sandick, J.W. van; Nieweg, O.E.; Rutgers, E.J.T.; Kroon, B.B.R.; Valdes Olmos, R.A.; Hoefnagel, C.A.

    2002-01-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures) after injection of technetium-99m nanocolloid. Anterior and prone lateral (hanging breast) planar images were obtained a few minutes and 4 h after injection. The sentinel node was intraoperatively identified with the aid of patent blue dye and a gamma-ray detection probe. A sentinel node was visualised on the 4-h images in 449 of 501 procedures (90%). This visualisation rate improved from 76% to 94% during the study period. Delayed imaging (5-23 h) in 19 patients whose sentinel nodes failed to show, resulted in visualisation in four of them. A repeat injection of radiocolloid in 11 patients revealed a sentinel node in six. In the end, the visualisation rate was 92%. The sentinel node was surgically retrieved in 24 of the remaining 42 patients with non-visualisation (57%). Sentinel nodes that were visualised were tumour-positive in 38% and non-visualised sentinel nodes were involved in 50% (χ 2 , P=0.17). In a multivariate regression analysis, scintigraphic non-visualisation was independently associated with increased patient age (P<0.001), decreased tracer dose (P<0.001) and increased number of tumour-positive lymph nodes (P=0.013). The use of a sufficient amount of radioactivity (at least 100 MBq) is recommended for lymphatic mapping in breast cancer, especially in elderly women. Delayed imaging and re-injection of the radioactive tracer increase the visualisation rate. The non-visualised sentinel node can be identified intraoperatively in more than half of the patients. (orig.)

  4. The hidden sentinel node in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, P.J.; Sandick, J.W. van; Nieweg, O.E.; Rutgers, E.J.T.; Kroon, B.B.R. [Department of Surgery, Netherlands Cancer Institute, Amsterdam (Netherlands); Valdes Olmos, R.A.; Hoefnagel, C.A. [Department of Nuclear Medicine, Netherlands Cancer Institute, Amsterdam (Netherlands)

    2002-03-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures) after injection of technetium-99m nanocolloid. Anterior and prone lateral (hanging breast) planar images were obtained a few minutes and 4 h after injection. The sentinel node was intraoperatively identified with the aid of patent blue dye and a gamma-ray detection probe. A sentinel node was visualised on the 4-h images in 449 of 501 procedures (90%). This visualisation rate improved from 76% to 94% during the study period. Delayed imaging (5-23 h) in 19 patients whose sentinel nodes failed to show, resulted in visualisation in four of them. A repeat injection of radiocolloid in 11 patients revealed a sentinel node in six. In the end, the visualisation rate was 92%. The sentinel node was surgically retrieved in 24 of the remaining 42 patients with non-visualisation (57%). Sentinel nodes that were visualised were tumour-positive in 38% and non-visualised sentinel nodes were involved in 50% ({chi}{sup 2}, P=0.17). In a multivariate regression analysis, scintigraphic non-visualisation was independently associated with increased patient age (P<0.001), decreased tracer dose (P<0.001) and increased number of tumour-positive lymph nodes (P=0.013). The use of a sufficient amount of radioactivity (at least 100 MBq) is recommended for lymphatic mapping in breast cancer, especially in elderly women. Delayed imaging and re-injection of the radioactive tracer increase the visualisation rate. The non-visualised sentinel node can be identified intraoperatively in more than half of the patients. (orig.)

  5. Geocoding uncertainty analysis for the automated processing of Sentinel-1 data using Sentinel-1 Toolbox software

    Science.gov (United States)

    Dostálová, Alena; Naeimi, Vahid; Wagner, Wolfgang; Elefante, Stefano; Cao, Senmao; Persson, Henrik

    2016-10-01

    One of the major advantages of the Sentinel-1 data is its capability to provide very high spatio-temporal coverage allowing the mapping of large areas as well as creation of dense time-series of the Sentinel-1 acquisitions. The SGRT software developed at TU Wien aims at automated processing of Sentinel-1 data for global and regional products. The first step of the processing consists of the Sentinel-1 data geocoding with the help of S1TBX software and their resampling to a common grid. These resampled images serve as an input for the product derivation. Thus, it is very important to select the most reliable processing settings and assess the geocoding uncertainty for both backscatter and projected local incidence angle images. Within this study, selection of Sentinel-1 acquisitions over 3 test areas in Europe were processed manually in the S1TBX software, testing multiple software versions, processing settings and digital elevation models (DEM) and the accuracy of the resulting geocoded images were assessed. Secondly, all available Sentinel-1 data over the areas were processed using selected settings and detailed quality check was performed. Overall, strong influence of the used DEM on the geocoding quality was confirmed with differences up to 80 meters in areas with higher terrain variations. In flat areas, the geocoding accuracy of backscatter images was overall good, with observed shifts between 0 and 30m. Larger systematic shifts were identified in case of projected local incidence angle images. These results encourage the automated processing of large volumes of Sentinel-1 data.

  6. Microstructure and mechanical performance of autogenously fibre laser beam welded Ti-6242 butt joints

    Energy Technology Data Exchange (ETDEWEB)

    Kashaev, Nikolai, E-mail: nikolai.kashaev@hzg.de; Pugachev, Dmitry; Ventzke, Volker; Fomin, Fedor; Burkhardt, Irmela; Enz, Josephin; Riekehr, Stefan

    2017-05-10

    This work deals with the effects of laser beam power, focus position and advance speed on the geometry, microstructure and mechanical properties such as the tensile strength and microhardness of autogenously fibre laser beam welded Ti-6Al-2Sn-4Zr-2Mo (denoted as Ti-6242) butt joints used for high temperature applications. The Ti-6242 sheet employed here is characterized by a globular (α+β) microstructure. Laser beam welded butt joints consisted of a martensitic fusion zone, inhomogeneous heat affected zones and equiaxed base materials. The microhardness increased from 330 HV 0.3 in base material to 430 HV 0.3 in fusion zone due to the martensitic transformation. Butt joints showed the base material level of strength in tensile test. The local increase in microhardness provided a shielding effect that protected the Ti-6242 butt joint against mechanical damage during the static tensile load test. The predicted critical total underfill depth that does not reduce the tensile strength of the weld was determined to be 25% of the specimen thickness. - Highlights: • Autogenous fibre LBW of Ti-6242 was successfully achieved. • Butt joints showed low levels of porosity and an appropriate seam geometry. • Base material level of strength achieved for tensile strength. • Predicted critical underfill depth is 25% of the specimen thickness.

  7. Sentinel lymph node biopsy: clinical relevance

    International Nuclear Information System (INIS)

    Howman-Giles, R.

    2002-01-01

    Sentinel lymph node biopsy (SLNB) has become an important technique in the management of patients with intermediate level melanoma, clinical operable breast cancer and some other cancers. The technique relies on lymphatic mapping to define the lymph drainage from a primary tumour with the premise that the lymph nodes, which directly drain from that area, will reflect the tumour status of the remainder of the node field. Current techniques use lymphoscintigraphy where a radioactive labelled particle and / or blue dye are injected intradermally or intraparenchymally to map the lymph drainage, often in conjunction with a radioactive gamma probe at surgery. In patients with melanoma the SLNB has improved the staging and prognostic information by more accurate determination of whether regional lymph nodes have metastatic spread. This has a major impact on patient management as those patients with negative nodes do not require regional lymph node dissection and have a significantly better prognosis. In our experience of over 3000 patients the combined sentinel node biopsy technique localised accurately 98% of sentinel lymph nodes. Lymphoscintigraphy in patients with melanoma to locate the sentinel lymph nodes involves the intradermal injection of a radiocolloid around the melanoma site or the excision biopsy site. Injections of 5 -10 MBq in 0.05-0.1ml/inj are used and typically 4 injections are usually required. Following tracer injection dynamic imaging is performed to follow the lymphatic collecting vessels until they reach the draining sentinel nodes. An image should be acquired as the vessels reach the node field so that the sentinel nodes directly receiving the channels can be identified and distinguished from any second tier nodes which may sometimes be seen. Delayed scans are performed 2 hours later at which time all regions which can possible drain the primary melanoma site are examined with 5-10 minute static images. The surface location of all sentinel nodes is

  8. Cigarettes butts and the case for an environmental policy on hazardous cigarette waste.

    Science.gov (United States)

    Novotny, Thomas E; Lum, Kristen; Smith, Elizabeth; Wang, Vivian; Barnes, Richard

    2009-05-01

    Discarded cigarette butts are a form of non-biodegradable litter. Carried as runoff from streets to drains, to rivers, and ultimately to the ocean and its beaches, cigarette filters are the single most collected item in international beach cleanups each year. They are an environmental blight on streets, sidewalks, and other open areas. Rather than being a protective health device, cigarette filters are primarily a marketing tool to help sell 'safe' cigarettes. They are perceived by much of the public (especially current smokers) to reduce the health risks of smoking through technology. Filters have reduced the machine-measured yield of tar and nicotine from burning cigarettes, but there is controversy as to whether this has correspondingly reduced the disease burden of smoking to the population. Filters actually may serve to sustain smoking by making it seem less urgent for smokers to quit and easier for children to initiate smoking because of reduced irritation from early experimentation. Several options are available to reduce the environmental impact of cigarette butt waste, including developing biodegradable filters, increasing fines and penalties for littering butts, monetary deposits on filters, increasing availability of butt receptacles, and expanded public education. It may even be possible to ban the sale of filtered cigarettes altogether on the basis of their adverse environmental impact. This option may be attractive in coastal regions where beaches accumulate butt waste and where smoking indoors is increasingly prohibited. Additional research is needed on the various policy options, including behavioral research on the impact of banning the sale of filtered cigarettes altogether.

  9. Cigarettes Butts and the Case for an Environmental Policy on Hazardous Cigarette Waste

    Directory of Open Access Journals (Sweden)

    Richard Barnes

    2009-05-01

    Full Text Available Discarded cigarette butts are a form of non-biodegradable litter. Carried as runoff from streets to drains, to rivers, and ultimately to the ocean and its beaches, cigarette filters are the single most collected item in international beach cleanups each year. They are an environmental blight on streets, sidewalks, and other open areas. Rather than being a protective health device, cigarette filters are primarily a marketing tool to help sell ‘safe’ cigarettes. They are perceived by much of the public (especially current smokers to reduce the health risks of smoking through technology. Filters have reduced the machine-measured yield of tar and nicotine from burning cigarettes, but there is controversy as to whether this has correspondingly reduced the disease burden of smoking to the population. Filters actually may serve to sustain smoking by making it seem less urgent for smokers to quit and easier for children to initiate smoking because of reduced irritation from early experimentation. Several options are available to reduce the environmental impact of cigarette butt waste, including developing biodegradable filters, increasing fines and penalties for littering butts, monetary deposits on filters, increasing availability of butt receptacles, and expanded public education. It may even be possible to ban the sale of filtered cigarettes altogether on the basis of their adverse environmental impact. This option may be attractive in coastal regions where beaches accumulate butt waste and where smoking indoors is increasingly prohibited. Additional research is needed on the various policy options, including behavioral research on the impact of banning the sale of filtered cigarettes altogether.

  10. 77 FR 39735 - Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines

    Science.gov (United States)

    2012-07-05

    ... revocation of the antidumping duty orders on stainless steel butt-weld pipe fittings From Italy, Malaysia... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 731-TA-865-867 (Second Review)] Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines Determination On the basis of the...

  11. Implementing Sentinels in the TARGIT BI Suite

    DEFF Research Database (Denmark)

    Middelfart, Morten; Pedersen, Torben Bach

    2011-01-01

    This paper describes the implementation of socalled sentinels in the TARGIT BI Suite. Sentinels are a novel type of rules that can warn a user if one or more measure changes in a multi-dimensional data cube are expected to cause a change to another measure critical to the user. Sentinels notify u...... pattern mining or correlation techniques. We demonstrate, through extensive experiments, that mining and usage of sentinels is feasible with good performance for the typical users on a real, operational data warehouse....

  12. Sentinel lymph node biopsy in oral cancer

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Grupe, Peter

    2005-01-01

    PURPOSE: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. MATERIAL......: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis (P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel...

  13. Detection of sentinel nodes with radiopharmaceuticals

    International Nuclear Information System (INIS)

    Yokoyama, Kunihiko; Michigishi, Takatoshi; Kinuya, Seigo; Konishi, Shota; Nakajima, Kenichi; Tonami, Norihisa

    2000-01-01

    Sentinel lymph nodes have been found to be an indicator of lymph node metastasis in breast cancer. In Japan, the theory and concept of sentinel lymph nodes in breast cancer have begun to be applied to carcinomas of the digestive system. Based on clinical experience in the detection of sentinel lymph nodes with radiopharmaceuticals, differences and similarities between the radiopharmaceuticals, methods, and techniques used to detect sentinel lymph nodes have been assessed in relation to breast cancer and carcinomas of the digestive system (including carcinomas of the esophagus and large intestine). The greatest difference between the methods used for breast and digestive cancers is the site of administration of the radiopharmaceutical. In breast cancer, the radiopharmaceutical is administered into a superficial organ (i.e., the mammary gland), whereas in carcinomas of the digestive system, it is administered into a deep organ (i.e., digestive tract). Another obvious difference is in lymph flow, i.e., the flow of the mammary glands is subcutaneous whereas lymph flow in the digestive tract is submucosal. Two radionuclide diagnostic methods are available to detect sentinel lymph nodes: sentinel lymphoscintigraphy with a gamma camera and a method that involves the use of a gamma probe intraoperatively. Radiopharmaceuticals used to detect sentinel lymph nodes must be smoothly transferred from the site of administration into the lymph, and uptake by the sentinel lymph node must continue for a long time without excessive flowing to lower reaches. The optimal particle size remains a matter of controversy, and no radiopharmaceuticals appropriate for lymphoscintigraphy have ever been approved in Japan. The authors compared the pharmacokinetics of three different radiopharmaceuticals used for sentinel lymphoscintigraphy in breast cancer ( 99m Tc-labeled albumin, 99m Tc-labeled tin colloid, and 99m Tc-labeled phytic acid) and founded that the detection rate was lowest with

  14. BioSentinel

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced Exploration Systems' (AES) BioSentinel project will develop, prototype, integrate, test, and prepare for the first spaceflight mission of a broadly...

  15. Application Regarding the Butt-Welding Through Intermediate Melting

    Directory of Open Access Journals (Sweden)

    Tudorel Ene

    2006-10-01

    Full Text Available It consists in presenting butt welding procedure through intermediate melting and its usage for manufacturing cutting tools type drill, tap screw, reamer by welding the active part (made of high-speed steel to the tool tail (made of unalloyed steel wit low carbon.

  16. Canonical analysis of sentinel-1 radar and sentinel-2 optical data

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Larsen, Rasmus

    2017-01-01

    This paper gives results from joint analyses of dual polarimety synthetic aperture radar data from the Sentinel-1 mission and optical data from the Sentinel-2 mission. The analyses are carried out by means of traditional canonical correlation analysis (CCA) and canonical information analysis (CIA......). Where CCA is based on maximising correlation between linear combinations of the two data sets, CIA maximises mutual information between the two. CIA is a conceptually more pleasing method for the analysis of data with very different modalities such as radar and optical data. Although a little...

  17. Sentinel Network

    Science.gov (United States)

    The Sentinel Network is an integrated, electronic, national medical product safety initiative that compiles information about the safe and effective use of medical products accessible to patients and healthcare practitioners.

  18. High risk of non-sentinel node metastases in a group of breast cancer patients with micrometastases in the sentinel node

    DEFF Research Database (Denmark)

    Tvedskov, Tove Filtenborg; Jensen, Maj-Britt; Lisse, Ida Marie

    2012-01-01

    Axillary lymph node dissection (ALND) in breast cancer patients with positive sentinel nodes is under debate. We aimed to establish two models to predict non-sentinel node (NSN) metastases in patients with micrometastases or isolated tumor cells (ITC) in sentinel nodes, to guide the decision for ...

  19. Comparison of 2002 Water Year and Historical Water-Quality Data, Upper Gunnison River Basin, Colorado

    Science.gov (United States)

    Spahr, N.E.

    2003-01-01

    Introduction: Population growth and changes in land-use practices have the potential to affect water quality and quantity in the upper Gunnison River basin. In 1995, the U.S. Geological Survey (USGS), in cooperation with local sponsors, City of Gunnison, Colorado River Water Conservation District, Crested Butte South Metropolitan District, Gunnison County, Mount Crested Butte Water and Sanitation District, National Park Service, Town of Crested Butte, and Upper Gunnison River Water Conservancy District, established a water-quality monitoring program in the upper Gunnison River basin to characterize current water-quality conditions and to assess the effects of increased urban development and other land-use changes on water quality. The monitoring network has evolved into two groups of stations, stations that are considered as long term and stations that are rotational. The long-term stations are monitored to assist in defining temporal changes in water quality (how conditions have changed over time). The rotational stations are monitored to assist in the spatial definition of water-quality conditions (how conditions differ throughout the basin) and to address local and short term concerns. Another group of stations (rotational group 2) will be chosen and sampled beginning in water year 2004. Annual summaries of the water-quality data from the monitoring network provide a point of reference for discussions regarding water-quality sampling in the upper Gunnison River basin. This summary includes data collected during water year 2002. The introduction provides a map of the sampling locations, definitions of terms, and a one-page summary of selected water-quality conditions at the network stations. The remainder of the summary is organized around the data collected at individual stations. Data collected during water year 2002 are compared to historical data (data collected for this network since 1995), state water-quality standards, and federal water-quality guidelines

  20. Contrast enhanced ultrasound of sentinel lymph nodes

    Directory of Open Access Journals (Sweden)

    XinWu Cui

    2013-03-01

    Full Text Available Sentinel lymph nodes are the first lymph nodes in the region that receive lymphatic drainage from a primary tumor. The detection or exclusion of sentinel lymph node micrometastases is critical in the staging of cancer, especially breast cancer and melanoma because it directly affects patient’s prognosis and surgical management. Currently, intraoperative sentinel lymph node biopsies using blue dye and radioisotopes are the method of choice for the detection of sentinel lymph node with high identification rate. In contrast, conventional ultrasound is not capable of detecting sentinel lymph nodes in most cases. Contrast enhanced ultrasound with contrast specific imaging modes has been used for the evaluation and diagnostic work-up of peripherally located suspected lymphadenopathy. The method allows for real-time analysis of all vascular phases and the visualization of intranodal focal “avascular” areas that represent necrosis or deposits of neoplastic cells. In recent years, a number of animal and human studies showed that contrast enhanced ultrasound can be also used for the detection of sentinel lymph node, and may become a potential application in clinical routine. Several contrast agents have been used in those studies, including albumin solution, hydroxyethylated starch, SonoVue®, Sonazoid® and Definity®. This review summarizes the current knowledge about the use of ultrasound techniques in detection and evaluation of sentinel lymph node.

  1. Sentinel node biopsy in penile cancer

    DEFF Research Database (Denmark)

    Jakobsen, J. K.; Krarup, K. P.; Sommer, P.

    2015-01-01

    INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow-up. In th......INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow...... died from complications. CONCLUSIONS: To our knowledge, this is the first complete national study on sentinel node biopsy. Penile cancer sentinel node biopsy with a close follow-up is a reliable lymph node staging and has few complications in a national multicentre setting. Inguinal lymph node...

  2. ANSYS Simulation of Residual Strains in Butt-welded Joints

    Directory of Open Access Journals (Sweden)

    A. Atroshenko

    2014-07-01

    Full Text Available The effect of thermal-strain cycle on residual strains in thin-walled circular seams of cylindrical shells using TIG butt welds was studied. Estimates were calculated using numerical modelling. The structure was made of corrosion-resistant austenitic steels.

  3. Comparison of 2008-2009 water years and historical water-quality data, upper Gunnison River Basin, Colorado

    Science.gov (United States)

    Solberg, Patricia A.; Moore, Bryan; Blacklock, Ty D.

    2012-01-01

    Population growth and changes in land use have the potential to affect water quality and quantity in the upper Gunnison River Basin. In 1995, the U.S. Geological Survey (USGS), in cooperation with the Bureau of Land Management, City of Gunnison, Colorado River Water Conservation District, Crested Butte South Metropolitan District, Gunnison County, Hinsdale County, Mount Crested Butte Water and Sanitation District, National Park Service, Town of Crested Butte, U.S. Forest Service, Upper Gunnison River Water Conservancy District, and Western State College, established a water-quality monitoring program in the upper Gunnison River Basin to characterize current water-quality conditions and to assess the effects of increased urban development and other land-use changes on water quality. The monitoring network has evolved into two groups of sites: (1) sites that are considered long term and (2) sites that are considered rotational. Data from the long-term sites assist in defining temporal changes in water quality (how conditions may change over time). The rotational sites assist in the spatial definition of water-quality conditions (how conditions differ throughout the basin) and address local and short-term concerns. Biannual summaries of the water-quality data from the monitoring network provide a point of reference for stakeholder discussions regarding the location and purpose of water-quality monitoring sites in the upper Gunnison River Basin. This report compares and summarizes the data collected during water years 2008 and 2009 to the historical data available at these sites. The introduction provides a map of the sampling sites, definitions of terms, and a one-page summary of selected water-quality conditions at the network sites. The remainder of the report is organized around the data collected at individual sites. Data collected during water years 2008 and 2009 are compared to historical data, State water-quality standards, and Federal water-quality guidelines

  4. Comparison of 2006-2007 Water Years and Historical Water-Quality Data, Upper Gunnison River Basin, Colorado

    Science.gov (United States)

    Solberg, P.A.; Moore, Bryan; Smits, Dennis

    2009-01-01

    Population growth and changes in land use have the potential to affect water quality and quantity in the upper Gunnison River basin. In 1995, the U.S. Geological Survey (USGS), in cooperation with the Bureau of Land Management, City of Gunnison, Colorado River Water Conservation District, Crested Butte South Metropolitan District, Gunnison County, Hinsdale County, Mount Crested Butte Water and Sanitation District, National Park Service, Town of Crested Butte, Upper Gunnison River Water Conservancy District, and Western State College established a water-quality monitoring program in the upper Gunnison River basin to characterize current water-quality conditions and to assess the effects of increased urban development and other land-use changes on water quality. The monitoring network has evolved into two groups of stations - stations that are considered long term and stations that are considered rotational. The long-term stations are monitored to assist in defining temporal changes in water quality (how conditions may change over time). The rotational stations are monitored to assist in the spatial definition of water-quality conditions (how conditions differ throughout the basin) and to address local and short-term concerns. Some stations in the rotational group were changed beginning in water year 2007. Annual summaries of the water-quality data from the monitoring network provide a point of reference for discussions regarding water-quality monitoring in the upper Gunnison River basin. This summary includes data collected during water years 2006 and 2007. The introduction provides a map of the sampling sites, definitions of terms, and a one-page summary of selected water-quality conditions at the network stations. The remainder of the summary is organized around the data collected at individual stations. Data collected during water years 2006 and 2007 are compared to historical data, State water-quality standards, and Federal water-quality guidelines. Data were

  5. 76 FR 43341 - Notice of Availability of the Record of Decision for the West Butte Wind Power Right-of-Way...

    Science.gov (United States)

    2011-07-20

    ... LVRWH09H0600; HAG 10-0338] Notice of Availability of the Record of Decision for the West Butte Wind Power Right... INFORMATION CONTACT: Steve Storo, BLM West Butte Wind Power Right-of-Way Project Lead: telephone (541) 416... INFORMATION: The applicant, West Butte Wind Power, LLC, filed right-of-way (ROW) application OR-065784 to...

  6. A Methodology for the Assessment of Unconventional (Continuous) Resources with an Application to the Greater Natural Buttes Gas Field, Utah

    International Nuclear Information System (INIS)

    Olea, Ricardo A.; Cook, Troy A.; Coleman, James L.

    2010-01-01

    The Greater Natural Buttes tight natural gas field is an unconventional (continuous) accumulation in the Uinta Basin, Utah, that began production in the early 1950s from the Upper Cretaceous Mesaverde Group. Three years later, production was extended to the Eocene Wasatch Formation. With the exclusion of 1100 non-productive ('dry') wells, we estimate that the final recovery from the 2500 producing wells existing in 2007 will be about 1.7 trillion standard cubic feet (TSCF) (48.2 billion cubic meters (BCM)). The use of estimated ultimate recovery (EUR) per well is common in assessments of unconventional resources, and it is one of the main sources of information to forecast undiscovered resources. Each calculated recovery value has an associated drainage area that generally varies from well to well and that can be mathematically subdivided into elemental subareas of constant size and shape called cells. Recovery per 5-acre cells at Greater Natural Buttes shows spatial correlation; hence, statistical approaches that ignore this correlation when inferring EUR values for untested cells do not take full advantage of all the information contained in the data. More critically, resulting models do not match the style of spatial EUR fluctuations observed in nature. This study takes a new approach by applying spatial statistics to model geographical variation of cell EUR taking into account spatial correlation and the influence of fractures. We applied sequential indicator simulation to model non-productive cells, while spatial mapping of cell EUR was obtained by applying sequential Gaussian simulation to provide multiple versions of reality (realizations) having equal chances of being the correct model. For each realization, summation of EUR in cells not drained by the existing wells allowed preparation of a stochastic prediction of undiscovered resources, which range between 2.6 and 3.4 TSCF (73.6 and 96.3 BCM) with a mean of 2.9 TSCF (82.1 BCM) for Greater Natural Buttes

  7. A parametric study of residual stresses in multipass butt-welded stainless steel pipes

    Energy Technology Data Exchange (ETDEWEB)

    Brickstad, B. [SAQ Inspection Ltd., Stockholm (Sweden); Josefson, L. [Chalmers Univ. of Technology, Goeteborg (Sweden). Div. of Solid Mechanics

    1996-06-01

    Multipass circumferential butt-welding of stainless steel pipes is simulated numerically in a non-linear thermo-mechanical FE-analysis. In particular, the through-thickness variation at the weld and heat affected zone, of the axial and hoop stresses and their sensitivity to variation in weld parameters are studied. Recommendations are given for the through thickness variation of the axial and hoop stresses to be used when assessing the growth of surface flaws at circumferential butt welds in nuclear piping system. 31 refs, 12 tabs, 54 figs.

  8. Concordance between peri-areolar blue dye and peri-incisional radiotracer injections for sentinel node mapping in patients with a history of primary breast cancer excisonal biopsy.

    Science.gov (United States)

    Mehrabibahar, M; Azizi, S; Jangjoo, A; Saremi, E; Kakhki, V R Dabbagh; Sadeghi, R; Chicken, D W; Keshtgar, M

    2014-01-01

    We evaluated the concordance between peri-areolar blue dye and peri-incisional radiotracer injections for axillary sentinel node mapping of patients with the history of previous breast lesion excisional biopsy. 80 patients with the history of previous excisional biopsy of the breast lesions were included. All patients received two injections of 99mTc-antimony sulfide colloid in both ends of incision line in an intradermal fashion. 2 mL patient blue V dye was injection to all patients in the peri-areolar area of the index quadrant after induction of anesthesia. All blue or hot nodes were harvested as sentinel lymph nodes. At least one sentinel node could be detected during surgery in 79 patients. In total 94 sentinel nodes were detected. All detected sentinel nodes were hot. In three patients sentinel nodes were detected by gamma probe but not blue dye. The tumor location in all of these patients was in the upper lateral quadrant and the incision line was extended into the axillary tail of the breast in all of them. 91 out of 94 sentinel nodes were stained blue, which amounts to 95.8% concordance between blue dye and radiotracer on a per node analysis. Single peri-areolar injection in the index quadrant would suffice for sentinel node mapping of patients with history of excisional biopsy. Care should be taken in patients with large excisional biopsy in the extreme proximity to axilla.

  9. Discovering Sentinel Rules for Business Intelligence

    DEFF Research Database (Denmark)

    Middelfart, Morten; Pedersen, Torben Bach

    2009-01-01

    This paper proposes the concept of sentinel rules for multi-dimensional data that warns users when measure data concerning the external environment changes. For instance, a surge in negative blogging about a company could trigger a sentinel rule warning that revenue will decrease within two month...

  10. Analysis and Prediction of the Billet Butt and Transverse Weld in the Continuous Extrusion Process of a Hollow Aluminum Profile

    Science.gov (United States)

    Lou, Shumei; Wang, Yongxiao; Liu, Chuanxi; Lu, Shuai; Liu, Sujun; Su, Chunjian

    2017-08-01

    In continuous extrusions of aluminum profiles, the thickness of the billet butt and the length of the discarded extrudate containing the transverse weld play key roles in reducing material loss and improving product quality. The formation and final distribution of the billet butt and transverse weld depend entirely on the flow behavior of the billet skin material. This study examined the flow behavior of the billet skin material as well as the formation and evolution of the billet butt and the transverse weld in detail through numerical simulation and a series of experiments. In practical extrusions, even if the billet skin is removed by lathe turning shortly before extrusion, billet skin impurities are still distributed around the transverse weld and in the billet butt. The thickness of the scrap billet butt and the length of the discarded extrudate containing the transverse weld can be exactly predicted via simulation.

  11. Sentinel-3 SAR Altimetry Toolbox

    Science.gov (United States)

    Benveniste, Jerome; Lucas, Bruno; DInardo, Salvatore

    2015-04-01

    The prime objective of the SEOM (Scientific Exploitation of Operational Missions) element is to federate, support and expand the large international research community that the ERS, ENVISAT and the Envelope programmes have build up over the last 20 years for the future European operational Earth Observation missions, the Sentinels. Sentinel-3 builds directly on a proven heritage of ERS-2 and Envisat, and CryoSat-2, with a dual-frequency (Ku and C band) advanced Synthetic Aperture Radar Altimeter (SRAL) that provides measurements at a resolution of ~300m in SAR mode along track. Sentinel-3 will provide exact measurements of sea-surface height along with accurate topography measurements over sea ice, ice sheets, rivers and lakes. The first of the two Sentinels is expected to be launched in early 2015. The current universal altimetry toolbox is BRAT (Basic Radar Altimetry Toolbox) which can read all previous and current altimetry mission's data, but it does not have the capabilities to read the upcoming Sentinel-3 L1 and L2 products. ESA will endeavour to develop and supply this capability to support the users of the future Sentinel-3 SAR Altimetry Mission. BRAT is a collection of tools and tutorial documents designed to facilitate the processing of radar altimetry data. This project started in 2005 from the joint efforts of ESA (European Space Agency) and CNES (Centre National d'Etudes Spatiales), and it is freely available at http://earth.esa.int/brat. The tools enable users to interact with the most common altimetry data formats, the BratGUI is the front-end for the powerful command line tools that are part of the BRAT suite. BRAT can also be used in conjunction with Matlab/IDL (via reading routines) or in C/C++/Fortran via a programming API, allowing the user to obtain desired data, bypassing the data-formatting hassle. BRAT can be used simply to visualise data quickly, or to translate the data into other formats such as netCDF, ASCII text files, KML (Google Earth

  12. 77 FR 10773 - Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines; Scheduling of...

    Science.gov (United States)

    2012-02-23

    ... Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines; Scheduling of Expedited Five-Year... orders on stainless steel butt-weld pipe fittings from Italy, Malaysia, and the Philippines would be... certificate of service. Determination.--The Commission has determined to exercise its authority to extend the...

  13. 76 FR 67146 - Stainless Steel Butt-Weld Pipe Fittings From Italy; Extension of Time Limit for Preliminary...

    Science.gov (United States)

    2011-10-31

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-475-828] Stainless Steel Butt-Weld... antidumping duty order on stainless steel butt-weld pipe fittings from Italy in the Federal Register. See... preliminary results of this review within the original time frame because it needs to obtain additional...

  14. Diagnosis the metastatic sentinel node with Tc-99m-MIBI

    International Nuclear Information System (INIS)

    Georgiev-Predic, M.; Predic, P.; Karner, I.; Dodig, D.

    2002-01-01

    Aim: The purpose of this study was to analyse the occurrence of visualisation malignancy of sentinel node during preoperative lymphoscintigraphy in breast cancer. To precisely diagnose the metastatic sentinel node is very difficult. Material and Methods:Preoperative lymphoscintigraphy was performed in 47 patients with breast cancer after injection of Tc-99m-MIBI. We injected 20-40 MBq Tc-99m-MIBI peritumoral. Anterior and prone lateral planar images were obtained 2h, 4h, 6h and 20h after injection. The uptake were in region of sentinel node calculed. The sentinel node was intraoperatively identified and histologically analysed. Results: In 27 patients with intraoperatively detected metastatic sentinel node was in 25 patients increased uptake in sentinel node on scintigrams after 20h detected. In 20 patients with intraoperatively non detected metastatic sentinel node was in 19 patients increased uptake on scintigrams ower 2h-6h detected. Conclusion: The results indicated that is lymphoscintigraphy with Tc-99m-MIBI is a new method for detection the preoperatively metastatic sentinel node

  15. The Western Environmental Technology Office (WETO), Butte, Montana. Technology summary

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    The Western Environmental Technology Office (WETO) is a multi-purpose engineering test facility located in Butte, Montana, and is managed by MSE, Inc. WETO seeks to contribute to environmental research by emphasizing projects to develop heavy metals removal and recovery processes, thermal vitrification systems, and waste minimization/pollution prevention technologies. WETO`s environmental technology research and testing activities focus on the recovery of usable resources from waste. In one of WETO`s areas of focus, groundwater contamination, water from the Berkeley Pit, located near the WETO site, is being used in demonstrations directed toward the recovery of potable water and metal from the heavy metal-bearing water. The Berkeley Pit is part of an inactive copper mine near Butte that was once part of the nation`s largest open-pit mining operation. The Pit contains approximately 25 billion gallons of Berkeley Pit groundwater and surface water containing many dissolved minerals. As part of DOE/OST`s Resource Recovery Project (RRP), technologies are being demonstrated to not only clean the contaminated water but to recover metal values such as copper, zinc, and iron with an estimated gross value of more than $100 million. When recovered, the Berkeley Pit waters could benefit the entire Butte valley with new water resources for fisheries, irrigation, municipal, and industrial use. At WETO, the emphasis is on environmental technology development and commercialization activities, which will focus on mine cleanup, waste treatment, resource recovery, and water resource management.

  16. The Western Environmental Technology Office (WETO), Butte, Montana. Technology summary

    International Nuclear Information System (INIS)

    1996-03-01

    The Western Environmental Technology Office (WETO) is a multi-purpose engineering test facility located in Butte, Montana, and is managed by MSE, Inc. WETO seeks to contribute to environmental research by emphasizing projects to develop heavy metals removal and recovery processes, thermal vitrification systems, and waste minimization/pollution prevention technologies. WETO's environmental technology research and testing activities focus on the recovery of usable resources from waste. In one of WETO's areas of focus, groundwater contamination, water from the Berkeley Pit, located near the WETO site, is being used in demonstrations directed toward the recovery of potable water and metal from the heavy metal-bearing water. The Berkeley Pit is part of an inactive copper mine near Butte that was once part of the nation's largest open-pit mining operation. The Pit contains approximately 25 billion gallons of Berkeley Pit groundwater and surface water containing many dissolved minerals. As part of DOE/OST's Resource Recovery Project (RRP), technologies are being demonstrated to not only clean the contaminated water but to recover metal values such as copper, zinc, and iron with an estimated gross value of more than $100 million. When recovered, the Berkeley Pit waters could benefit the entire Butte valley with new water resources for fisheries, irrigation, municipal, and industrial use. At WETO, the emphasis is on environmental technology development and commercialization activities, which will focus on mine cleanup, waste treatment, resource recovery, and water resource management

  17. Hepatic angiographic findings of ruptured hepatocellular carcinoma: 'Sentinel signs' versus extravasation

    International Nuclear Information System (INIS)

    Yun, Seong Jong; Nam, Deok Ho

    2014-01-01

    This study retrospectively compared the accuracy of angiographic sentinel signs (sentinel vessels, hypovascular areas, and delayed dots) with extravasation in the diagnosis of ruptured hepatocellular carcinoma (HCC). Sixteen patients diagnosed with HCC between March 2007 and November 2011 were evaluated. Among the patients, we identified 32 HCCs (19 ruptured, 13 unruptured), and assessed all HCCs by hepatic angiography with regard to extravasation, sentinel vessels, hypovascular areas, and delayed dots. We compared the sensitivity and specificity of the sentinel signs with those of the extravasation for the diagnosis of a ruptured HCC. For the angiographic diagnosis of a ruptured HCC, the sensitivity of the sentinel signs (sentinel vessel, 63.2%; hypovascular area, 89.5%; delayed dot, 72.7%) was higher than the sensitivity of extravasation (15.8%). The difference in sensitivity between each sentinel sign and extravasation was statistically significant (sentinel vessel, p = 0.012; hypovascular area, p < 0.001; delayed dot, p 0.039). The specificity of sentinel signs for the diagnosis of ruptured HCC was not statistically different from the specificity of extravasation. Sentinel signs are more accurate than extravasation for the angiographic diagnosis of a ruptured HCC.

  18. Human and animal sentinels for shared health risks

    Directory of Open Access Journals (Sweden)

    Peter Rabinowitz, MD, MPH

    2009-03-01

    Full Text Available The tracking of sentinel health events in humans in order to detect and manage disease risks facing a larger population is a well accepted technique applied to influenza, occupational conditions and emerging infectious diseases. Similarly, animal health professionals routinely track disease events in sentinel animal colonies and sentinel herds. The use of animals as sentinels for human health threats, or of humans as sentinels for animal disease risk, dates back at least to the era when coal miners brought caged canaries into mines to provide early warning of toxic gases. Yet the full potential of linking animal and human health information to provide warning of such ‘shared risks’ from environmental hazards has not been realised. Reasons appear to include the professional segregation of human and animal health communities, the separation of human and animal surveillance data and evidence gaps in the linkages between human and animal responses to environmental health hazards. The ‘One Health initiative’ and growing international collaboration in response to pandemic threats, coupled with development in the fields of informatics and genomics, hold promise for improved sentinel event coordination in order to detect and reduce environmental health threats shared between species.

  19. The multispectral instrument of the Sentinel2 program

    Science.gov (United States)

    Cazaubiel, V.; Chorvalli, Vincent; Miesch, Christophe

    2017-11-01

    The Sentinel-2 program will provide a permanent record of comprehensive data to help inform the agricul-tural sector (utilisation, coverage), forestry industry (population, damage, forest fires), disaster control (management, early warning) and humanitarian relief programmes. Sentinel-2 will also be able to observe natural disasters such as floods, volcanic eruptions, subsidence and landslides. In the Sentinel-2 mission programme, Astrium in Friedrichshafen is responsible for the satellite's system design and platform, as well as for satellite integration and testing. Astrium Toulouse will supply the Multi-Spectral imaging Instrument (MSI), and Astrium Spain will be in charge of the satellite's structure and will produce its thermal equipment and cable harness. The industrial core team also comprises Jena Optronik (Germany), Boostec (France), Sener and GMV (Spain). Sentinel-2 is intended to image the Earth's landmasses from its orbit for at least 7.25 years. In addition, its onboardresources will be designed so that the mission can be prolonged by an extra five years. From 2012 onwards, the 1.1-metric-ton satellite will circle the Earth in a sun-synchronous, polar orbit at an altitude of 786kilometres, fully covering the planet's landmasses in just ten days. The multi-spectral instrument (MSI) will generate optical images in 13 spectral channels in the visible and shortwave infrared range down to a resolution of 10 metres with an image width of 290 kilometres. The instrument is composed of two main parts: • The telescope assembly , combining in one instrument both VNIR and SWIR channels, is mounted on the upper plate of the Bus • The Video and Compression Electronic Units mounted inside the Bus. This telescope is based on a Three Mirror Anastigmat optical concept. This three mirror optical combination is corrected from spherical aberration, coma and astigmatism. It provides a large field of view with very good optical quality. The telescope mirrors and

  20. Development of radiographic technique for examining k-type butt weld

    International Nuclear Information System (INIS)

    Barui, K.L.; Bhattacharyya, B.

    1983-01-01

    An attempt is made to develop a radiographic technique for examining K-type full penetration butt joints in heavy duty crane girders. The existing standard techniques of radiographic examination is found to be unsuitable to assess the internal defects properly. The examination technique reported here is successful in detecting not only the nature of the internal defects but also their degree of severities - from which clues for avoiding the most probable defects can be found out. The results of radiographic examination applied on the K-type butt joints of heavy duty crane girders have been discussed and it is specified that the acceptable limit of the defects must lie between 'blue' and 'green' according to the IIW colour code. Much work is yet to be done before standard specifications regarding the acceptibility of the defects in the actual job can be formulated. (author)

  1. The SENTINEL-3 Mission: Overview and Status

    Science.gov (United States)

    Benveniste, J.; Mecklenburg, S.

    2015-12-01

    The Copernicus Programme, being Europe's Earth Observation and Monitoring Programme led by the European Union, aims to provide, on a sustainable basis, reliable and timely services related to environmental and security issues. The Sentinel-3 mission forms part of the Copernicus Space Component. Its main objectives, building on the heritage and experience of the European Space Agency's (ESA) ERS and ENVISAT missions, are to measure sea-surface topography, sea- and land-surface temperature and ocean- and land-surface colour in support of ocean forecasting systems, and for environmental and climate monitoring. The series of Sentinel-3 satellites will ensure global, frequent and near-real time ocean, ice and land monitoring, with the provision of observation data in routine, long term (up to 20 years of operations) and continuous fashion, with a consistent quality and a high level of reliability and availability. The Sentinel-3 missions will be jointly operated by ESA and EUMETSAT. ESA will be responsible for the operations, maintenance and evolution of the Sentinel-3 ground segment on land related products and EUMETSAT for the marine products. The Sentinel-3 ground segment systematically acquires, processes and distributes a set of pre-defined core data products. Sentinel-3A is foreseen to be launched at the beginning of November 2015. The paper will give an overview on the mission, its instruments and objectives, the data products provided, the mechanisms to access the mission's data, and if available first results.

  2. The hidden sentinel node in breast cancer

    NARCIS (Netherlands)

    Tanis, P. J.; van Sandick, J. W.; Nieweg, O. E.; Valdés Olmos, R. A.; Rutgers, E. J. T.; Hoefnagel, C. A.; Kroon, B. B. R.

    2002-01-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures)

  3. Sentinel-3 for Science

    Science.gov (United States)

    Benveniste, J.; Regner, P.; Desnos, Y. L.

    2015-12-01

    The Scientific Exploitation of Operational Mission (SEOM) programme element (http://seom.esa.int/) is part of the ESA's Fourth Earth Observation Envelope Programme (2013-2017). The prime objective is to federate, support and expand the international research community that the ERS, ENVISAT and the Envelope programmes have built up over the last 25 years. It aims to further strengthen the leadership of the European Earth Observation research community by enabling them to extensively exploit future European operational EO missions. SEOM is enabling the science community to address new scientific research that are opened by free and open access to data from operational EO missions. The Programme is based on community-wide recommendations for actions on key research issues, gathered through a series of international thematic workshops and scientific user consultation meetings such as the Sentinel-3 for Science Workshop held last June in Venice, Italy (see http://seom.esa.int/S3forScience2015). The 2015 SEOM work plan includes the launch of new R&D studies for scientific exploitation of the Sentinels, the development of open-source multi-mission scientific toolboxes, the organization of advanced international training courses, summer schools and educational materials, as well as activities for promoting the scientific use of EO data, also via the organization of Workshops. This paper will report the recommendations from the International Scientific Community concerning the Sentinel-3 Scientific Exploitation, as expressed in Venice, keeping in mind that Sentinel-3 is an operational mission to provide operational services (see http://www.copernicus.eu).

  4. Computational Modeling of Microstructural-Evolution in AISI 1005 Steel During Gas Metal Arc Butt Welding

    Science.gov (United States)

    2013-05-01

    H.K.D.H. Bhadeshia, A Model for the Microstruc- ture of Some Advanced Bainitic Steels , Mater. Trans., 1991, 32, p 689–696 19. G.J. Davies and J.G. Garland...REPORT Computational Modeling of Microstructural-Evolution in AISI 1005 Steel During Gas Metal Arc Butt Welding 14. ABSTRACT 16. SECURITY...Computational Modeling of Microstructural-Evolution in AISI 1005 Steel During Gas Metal Arc Butt Welding Report Title ABSTRACT A fully coupled (two-way

  5. Incorporation of cigarette butts into nests reduces nest ectoparasite load in urban birds: new ingredients for an old recipe?

    Science.gov (United States)

    Suárez-Rodríguez, Monserrat; López-Rull, Isabel; Garcia, Constantino Macías

    2013-02-23

    Birds are known to respond to nest-dwelling parasites by altering behaviours. Some bird species, for example, bring fresh plants to the nest, which contain volatile compounds that repel parasites. There is evidence that some birds living in cities incorporate cigarette butts into their nests, but the effect (if any) of this behaviour remains unclear. Butts from smoked cigarettes retain substantial amounts of nicotine and other compounds that may also act as arthropod repellents. We provide the first evidence that smoked cigarette butts may function as a parasite repellent in urban bird nests. The amount of cellulose acetate from butts in nests of two widely distributed urban birds was negatively associated with the number of nest-dwelling parasites. Moreover, when parasites were attracted to heat traps containing smoked or non-smoked cigarette butts, fewer parasites reached the former, presumably due to the presence of nicotine. Because urbanization changes the abundance and type of resources upon which birds depend, including nesting materials and plants involved in self-medication, our results are consistent with the view that urbanization imposes new challenges on birds that are dealt with using adaptations evolved elsewhere.

  6. Study on Tensile Fatigue Behavior of Thermal Butt Fusion in Safety Class III High-Density Polyethylene Buried Piping in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Sung; Lee, Young Ju [Sunchon National University, Suncheon (Korea, Republic of); Oh, Young Jin [KEPCO E and C, Yongin (Korea, Republic of)

    2015-01-15

    High-density polyethylene (HDPE) piping, which has recently been applied to safety class III piping in nuclear power plants, can be butt-joined through the thermal fusion process, which heats two fused surfaces and then subject to axial pressure. The thermal fusion process generates bead shapes on the butt fusion. The stress concentrations caused by the bead shapes may reduce the fatigue lifetime. Thus, investigating the effect of the thermal butt fusion beads on fatigue behavior is necessary. This study examined the fatigue behavior of thermal butt fusion via a tensile fatigue test under stress-controlled conditions using finite element elastic stress analysis. Based on the results, the presence of thermal butt fusion beads was confirmed to reduce the fatigue lifetime in the low-cycle fatigue region while having a negligible effect in the medium- and high-cycle fatigue regions.

  7. Study on Tensile Fatigue Behavior of Thermal Butt Fusion in Safety Class III High-Density Polyethylene Buried Piping in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Jong Sung; Lee, Young Ju; Oh, Young Jin

    2015-01-01

    High-density polyethylene (HDPE) piping, which has recently been applied to safety class III piping in nuclear power plants, can be butt-joined through the thermal fusion process, which heats two fused surfaces and then subject to axial pressure. The thermal fusion process generates bead shapes on the butt fusion. The stress concentrations caused by the bead shapes may reduce the fatigue lifetime. Thus, investigating the effect of the thermal butt fusion beads on fatigue behavior is necessary. This study examined the fatigue behavior of thermal butt fusion via a tensile fatigue test under stress-controlled conditions using finite element elastic stress analysis. Based on the results, the presence of thermal butt fusion beads was confirmed to reduce the fatigue lifetime in the low-cycle fatigue region while having a negligible effect in the medium- and high-cycle fatigue regions

  8. Ultrasonic wave propagation in real-life austenitic V-butt welds: Numerical modeling and validation

    International Nuclear Information System (INIS)

    Hannemann, R.; Marklein, R.; Langenberg, K. J.; Schurig, C.; Koehler, B.; Walte, F.

    2000-01-01

    In nondestructive testing the evaluation of austenitic steel welds with ultrasound is a commonly used method. But, since the wave propagation, scattering, and diffraction effects in such complicated media are hardly understood, computer simulations are very helpful to increase the knowledge of the physical phenomena in such samples. A particularly powerful numerical time domain modeling tool is the well established Elastodynamic Finite Integration Technique (EFIT). Recently, EFIT has been extended to simulate elastic waves in inhomogeneous anisotropic media. In this paper, the step-by-step evaluation of ultrasonic wave propagation in inhomogeneous anisotropic media will be described and the results will be validated against measurements. As a simplified model, a V-butt weld with perpendicular grain structure is investigated. The coincidence between the B Scans of the simulation and the measurement of an idealized V-butt weld is remarkable and even effects predicted by theory and simulation - the appearance of two coupled quasi-SV waves - can be observed. As a next step, an improved and more realistic model of the grain orientation inside the V-butt weld is introduced. This model has been implemented in the EFIT code and has been validated against measurements. For this verification, measured and simulated B-Scans for a real-life V-butt weld have been compared and a significant coincidence has been observed. Furthermore, the main pulses in the B-Scans are interpreted by analyzing the snapshot-movies of the wavefronts

  9. Preliminary geologic map of the Sleeping Butte volcanic centers

    International Nuclear Information System (INIS)

    Crowe, B.M.; Perry, F.V.

    1991-07-01

    The Sleeping Butte volcanic centers comprise two, spatially separate, small-volume ( 3 ) basaltic centers. The centers were formed by mildly explosive Strombolian eruptions. The Little Black Peak cone consists of a main scoria cone, two small satellitic scoria mounds, and associated lobate lava flows that vented from sites at the base of the scoria cone. The Hidden Cone center consists of a main scoria cone that developed on the north-facing slope of Sleeping Butte. The center formed during two episodes. The first included the formation of the main scoria cone, and venting of aa lava flows from radial dikes at the northeast base of the cone. The second included eruption of scoria-fall deposits from the summit crater. The ages of the Little Black Peak and the Hidden Cone are estimated to be between 200 to 400 ka based on the whole-rock K-Ar age determinations with large analytical undertainty. This age assignment is consistent with qualitative observations of the degree of soil development and geomorphic degradation of volcanic landforms. The younger episode of the Hidden Cone is inferred to be significantly younger and probably of Late Pleistocene or Holocene age. This is based on the absence of cone slope rilling, the absence of cone-slope apron deposits, and erosional unconformity between the two episodes, the poor horizon- development of soils, and the presence of fall deposits on modern alluvial surfaces. Paleomagnetic data show that the centers record similar but not identical directions of remanent magnetization. Paleomagnetic data have not been obtained for the youngest deposits of the Hidden Cone center. Further geochronology, soils, geomorphic, and petrology studies are planned of the Sleeping Butte volcanic centers 20 refs., 3 figs

  10. Investigation and control of factors influencing resistance upset butt welding.

    NARCIS (Netherlands)

    Kerstens, N.F.H.

    2010-01-01

    The purpose of this work is to investigate the factors influencing the resistance upset butt welding process to obtain an understanding of the metal behaviour and welding process characteristics, so that new automotive steels can be welded with reduced development time and fewer failures in

  11. Sentinel lymph node imaging in breast cancer

    International Nuclear Information System (INIS)

    Kim, Byung Tae

    1999-01-01

    Currently, dissection of the axillary or regional lymph nodes is considered the standard staging procedure in breast cancer. However, accumulating evidence is becoming available that the sentinel node concept may provide the same or even better staging information. In the case of melanoma, it is proven that the histological characteristics of the sentinel node reflect the histological characteristics of the distal part of the lymphatic basin. Morbidity can be reduced significantly by the use of sentinel node dissection as several authors have reported successful introduction of this technique into clinical practice. But in breast cancer patients, there are significant differences in practice relating to the technology, such as radiopharmaceuticals, injection sites, volume of injectate, combination with vital blue dye, preoperative lymphoscintigraphy, etc. Valuable reports on these topics appeared in recent journals. This review is a summary of those reports for nuclear physicians interested in sentinel node detection by lymphoscintigraphy in breast cancer patients

  12. National uranium resource evaluation, Dickinson quadrangle, North Dakota

    International Nuclear Information System (INIS)

    Lee, C.H.; Pack, D.D.; Galipeau, J.M.; Lawton, D.E.

    1982-05-01

    The Dickinson Quadrangle, North Dakota, was evaluated to a depth of 1500 m to identify environments and delineate areas favorable for uranium deposits. Criteria used in the evaluation were developed for the National Uranium Resource Evaluation program. The evaluation primarily consisted of a surface study, subsurface investigation, and an in-house ground-water geochemical study. These studies were augumented by aerial radiometric and hydrogeochemical and stream-sediment studies. The evaluation results indicate that the Sentinel Butte and Tongue River Members of the Fort Union Formation have environments favorable for uraniferous lignite deposits. The Sentinel Butte, Tongue River, and Ludlow Members of the Fort Union Formation are favorable for sandstone uranium deposits. Environments unfavorable for uranium deposits are the remaining Cenozoic rocks and all the rocks of the Cretaceous

  13. 75 FR 60804 - Notice of Availability of the Final Environmental Impact Statement for the West Butte Wind Power...

    Science.gov (United States)

    2010-10-01

    ... Wind Power Right-of-Way, Crook and Deschutes Counties, OR AGENCY: Bureau of Land Management, Interior... Final Environmental Impact Statement (EIS) for the West Butte Wind Power Right-of-Way and by this Notice... Register notice. FOR FURTHER INFORMATION CONTACT: Steve Storo, BLM West Butte Wind Power Right of Way...

  14. Synergy between Sentinel-1 radar time series and Sentinel-2 optical for the mapping of restored areas in Danube delta

    Science.gov (United States)

    Niculescu, Simona; Lardeux, Cédric; Hanganu, Jenica

    2018-05-01

    Wetlands are important and valuable ecosystems, yet, since 1900, more than 50 % of wetlands have been lost worldwide. An example of altered and partially restored coastal wetlands is the Danube Delta in Romania. Over time, human intervention has manifested itself in more than a quarter of the entire Danube surface. This intervention was brutal and has rendered ecosystem restoration very difficult. Studies for the rehabilitation / re-vegetation were started immediately after the Danube Delta was declared as a Biosphere Reservation in 1990. Remote sensing offers accurate methods for detecting and mapping change in restored wetlands. Vegetation change detection is a powerful indicator of restoration success. The restoration projects use vegetative cover as an important indicator of restoration success. To follow the evolution of the vegetation cover of the restored areas, satellite images radar and optical of last generation have been used, such as Sentinel-1 and Sentinel-2. Indeed the sensor sensitivity to the landscape depends on the wavelength what- ever radar or optical data and their polarization for radar data. Combining this kind of data is particularly relevant for the classification of wetland vegetation, which are associated with the density and size of the vegetation. In addition, the high temporal acquisition frequency of Sentinel-1 which are not sensitive to cloud cover al- low to use temporal signature of the different land cover. Thus we analyse the polarimetric and temporal signature of Sentinel-1 data in order to better understand the signature of the different study classes. In a second phase, we performed classifications based on the Random Forest supervised classification algorithm involving the entire Sentinel-1 time series, then starting from a Sentinel-2 collection and finally involving combinations of Sentinel-1 and -2 data.

  15. Geology of Pine and Crater Buttes: two basaltic constructs on the far eastern Snake River Plain

    International Nuclear Information System (INIS)

    Mazierski, P.F.; King, J.S.

    1987-01-01

    The emplacement history and petrochemical evolution of the volcanics associated with Pine Butte, Crater Butte, and other nearby vents are developed and described. Four major vents were identified in the study area and their associated eruptive products were mapped. All of the vents show a marked physical elongation or linear orientation coincident with the observed rift set. Planetary exploration has revealed the importance of volcanic processes in the genesis and modification of extraterrestrial surfaces. Interpretation of surface features has identified plains-type basaltic volcanism in various mare regions of the Moon and the volcanic provinces of Mars. Identification of these areas with features that appear analogous to those observed in the Pine Butte area suggests similar styles of eruption and mode of emplacement. Such terrestrial analogies serve as a method to interpret the evolution of volcanic planetary surfaces on the inner planets

  16. Lymphoscintigraphy detecting alterations of upper limb lymphatic flow following early sentinel lymph node biopsy in breast cancer

    Directory of Open Access Journals (Sweden)

    Sarri AJ

    2017-04-01

    surgery was performed.Results: The mean age was 54.53±9.03 years (36–73 years, the mean BMI was 27.16±4.16 kg/m2 (19.3–34.42, and the mean number of lymph nodes removed from each patient was 1.6±0.74 (1–3. There was significant difference in the time between surgery and the realization of LS (p=0.002; Mann–Whitney U test, but in an inverse relationship, the higher was the range, the smaller was the lymphatic flow, indicating a gradual reduction of lymphatic flow after surgery (Spearman’s p=0.498, with p=0.013.Conclusion: Upper limb lymphatic flow gradually decreased after the SLNB and conservative breast surgery in this study, but these results are exploratory because of the small sample size. Further studies are needed to confirm and to investigate more in depth these findings. Keywords: lymph node sentinel biopsy, lymphoscintigraphy, nuclear medicine, lymphedema, breast cancer

  17. 77 FR 61020 - Notice of Availability of Final Environmental Impact Statement for the Sigurd to Red Butte No. 2...

    Science.gov (United States)

    2012-10-05

    ...; UTU-83067] Notice of Availability of Final Environmental Impact Statement for the Sigurd to Red Butte... (BLM) has prepared a Final Environmental Impact Statement (EIS) for the Sigurd to Red Butte No. 2--345...; Utah School and Institutional Trust Lands Administration; Millard, Sevier, Beaver, Iron, and Washington...

  18. Et cigaretskod, en donation, en renere by: A cigarette butt, a donation, a cleaner city

    OpenAIRE

    Bengtsen, Monica; Patursson, Guttormur; Nedergaard, Sofie Tarpø; Madsen, Maria Chas; Drews, Anna Ørsted; Bach, Katrine Møller

    2013-01-01

    This project concerns an explanation of the problem of cigarette butts lying in the streets of Copenhagen. By using elements of the theory of nudging we have designed an ashtray ment to pledge smokers not to throw their butt in the streets. The design is a response to a design competition published by the municipality of Copenhagen, as an attempt to be the cleanest capital in Europe by the year 2015. The core of the design presentation is in cooperation with private firms, who have obligated ...

  19. Sentinel Node Detection in Head and Neck Malignancies: Innovations in Radioguided Surgery

    Directory of Open Access Journals (Sweden)

    L. Vermeeren

    2009-01-01

    Full Text Available Sentinel node mapping is becoming a routine procedure for staging of various malignancies, because it can determine lymph node status more precisely. Due to anatomical problems, localizing sentinel nodes in the head and neck region on the basis of conventional images can be difficult. New diagnostic tools can provide better visualization of sentinel nodes. In an attempt to keep up with possible scientific progress, this article reviews new and innovative tools for sentinel node localization in this specific area. The overview comprises a short introduction of the sentinel node procedure as well as indications in the head and neck region. Then the results of SPECT/CT for sentinel node detection are described. Finally, a portable gamma camera to enable intraoperative real-time imaging with improved sentinel node detection is described.

  20. Estimation of dose and exposure at sentinel node study

    International Nuclear Information System (INIS)

    Skopljak, A.; Kucukalic-Selimovic, E.; Beslic, N.; Begic, A.; Begovic-Hadzimuratovic, S.; Drazeta, Z.; Beganovic, A.

    2005-01-01

    The purpose of this study was to estimate the dose end exposure in staff involved in sentinel node procedure for breast cancer patients. The Institute of Nuclear Medicine in Sarajevo uses a protocol for lymphoscintigraphy of the sentinel node whereby 13 MBq of 9 9mT c nanocoll are used. In this study, we measured radiation doses and exposure of a nuclear medicine physician and a technologist, as well as a surgeon performing sentinel node lymphoscintigraphy and biopsy. Dose and exposure were calculated using the equation in which we have gamma constant for 9 9mT c. Calculations were made for different times of exposure and distance. In Table 1. we estimated the dose and exposure during sentinel node study. Radiation levels were very low and the most exposed hospital staff performing sentinel node study were nuclear medicine physicians. The doses on the hands of surgeons were negligible 8 hours after exposure.(author)

  1. Sentinel Node Biopsy in Melanoma: A Short Update

    Science.gov (United States)

    Ferrara, Gerardo; Partenzi, Antonietta; Filosa, Alessandra

    2018-01-01

    Several controversies are still ongoing about sentinel node biopsy in melanoma. It is basically a staging procedure for melanoma > 0.75 mm in thickness or for thinner melanoma in the presence of ulceration, high mitotic rate, and/or lymphovascular invasion. Complete lymph node dissection after a positive sentinel node can also allow a better locoregional disease control but seems not to prevent the development of distant metastases. The use of sentinel node biopsy in atypical Spitz tumors should be discouraged because of their peculiar biological properties. PMID:29719827

  2. Feasibility of sentinel node lymphoscintigraphy in stage I testicular cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, Pieter J.; Nieweg, Omgo E. [Department of Surgery, Netherlands Cancer Institute, Amsterdam (Netherlands); Horenblas, Simon [Department of Urology, Netherlands Cancer Institute, Amsterdam (Netherlands); Olmos, Renato Valdes A.; Hoefnagel, Cornelis A. [Department of Nuclear Medicine, The Netherlands Cancer Institute, Amsterdam (Netherlands)

    2002-05-01

    The aim of this study was to investigate the feasibility of lymphoscintigraphy for sentinel node identification in testicular cancer. Five patients with clinical stage I testicular cancer were prospectively included. A single dose of technetium-99m nanocolloid (mean dose 99 MBq, volume 0.2 ml) was injected into the funiculus in the first patient and into the testicular parenchyma in the following four patients. Dynamic lymphoscintigraphy was performed over 10 min, followed by early and late static images after 15 min and 2 to 24 h, respectively. Lymphoscintigraphy was followed by laparoscopic sentinel node biopsy on the same day in the last two patients using patent blue dye and an endoscopic gamma probe. The funicular administration route showed five hot spots in the right inguinal region after 2 h. Intratesticular administration resulted in sentinel node visualisation in three of the four patients. Dynamic images showed afferent lymphatic vessels to one sentinel node in the left para-aortic region in two patients and two sentinel nodes in the left para-aortic region in another patient. Sentinel nodes were intraoperatively identified in one of two patients who underwent laparoscopic exploration. It is concluded that lymphoscintigraphy for sentinel node identification is feasible in stage I testicular cancer using intratesticular radiocolloid administration. (orig.)

  3. Getting ready for the arrival of Sentinel data

    Science.gov (United States)

    Aschbacher, Josef; Milagro Perez, Maria Pilar

    2013-04-01

    The European Union (EU) and the European Space Agency (ESA) have developed the Global Monitoring for Environment and Security (GMES), being renamed to Copernicus, programme as Europe's answer to the vital need for joined-up data about our climate, environment and security. Through a unique combination of satellite, atmospheric and Earth-based monitoring systems, the initiative will provide new insight into the state of the land, sea and air, providing policymakers, scientists, businesses and the public with accurate and timely information. GMES capabilities include monitoring and forecasting of climatic change, flood risks, soil and coastal erosion, crop and fish resources, air pollution, greenhouse gases, iceberg distribution and snow cover, among others. To accomplish this, GMES has been divided into three main components: Space, In-situ and Services. The Space Component, led by ESA, comprises five types of new dedicated satellites called Sentinels. These missions carry a range of technologies, such as radar and multi-spectral imaging instruments for land, ocean and atmospheric monitoring. While the Sentinel satellites are currently being developed by ESA specifically to meet the needs of GMES, the Contributing Missions, operated by national agencies or commercial entities, are already providing a wealth of data for GMES services, and will continue to deliver complementary data after the Sentinels are in orbit. An integrated Ground Segment ensures access to Sentinels and Contributing Missions data. Access to Sentinel data is governed by the Sentinel data policy, which is part of a wider GMES data and information access policy. The Sentinel data policy envisages free and open access, subject to restrictions only if security or other European interests need to be preserved. As regards the Contributing Missions, the data policy of the mission owners will be respected for the purpose of providing data to GMES service users. The first in the fleet of dedicated

  4. A mathematical prediction model incorporating molecular subtype for risk of non-sentinel lymph node metastasis in sentinel lymph node-positive breast cancer patients: a retrospective analysis and nomogram development.

    Science.gov (United States)

    Wang, Na-Na; Yang, Zheng-Jun; Wang, Xue; Chen, Li-Xuan; Zhao, Hong-Meng; Cao, Wen-Feng; Zhang, Bin

    2018-04-25

    Molecular subtype of breast cancer is associated with sentinel lymph node status. We sought to establish a mathematical prediction model that included breast cancer molecular subtype for risk of positive non-sentinel lymph nodes in breast cancer patients with sentinel lymph node metastasis and further validate the model in a separate validation cohort. We reviewed the clinicopathologic data of breast cancer patients with sentinel lymph node metastasis who underwent axillary lymph node dissection between June 16, 2014 and November 16, 2017 at our hospital. Sentinel lymph node biopsy was performed and patients with pathologically proven sentinel lymph node metastasis underwent axillary lymph node dissection. Independent risks for non-sentinel lymph node metastasis were assessed in a training cohort by multivariate analysis and incorporated into a mathematical prediction model. The model was further validated in a separate validation cohort, and a nomogram was developed and evaluated for diagnostic performance in predicting the risk of non-sentinel lymph node metastasis. Moreover, we assessed the performance of five different models in predicting non-sentinel lymph node metastasis in training cohort. Totally, 495 cases were eligible for the study, including 291 patients in the training cohort and 204 in the validation cohort. Non-sentinel lymph node metastasis was observed in 33.3% (97/291) patients in the training cohort. The AUC of MSKCC, Tenon, MDA, Ljubljana, and Louisville models in training cohort were 0.7613, 0.7142, 0.7076, 0.7483, and 0.671, respectively. Multivariate regression analysis indicated that tumor size (OR = 1.439; 95% CI 1.025-2.021; P = 0.036), sentinel lymph node macro-metastasis versus micro-metastasis (OR = 5.063; 95% CI 1.111-23.074; P = 0.036), the number of positive sentinel lymph nodes (OR = 2.583, 95% CI 1.714-3.892; P model based on the results of multivariate analysis was established to predict the risk of non-sentinel

  5. SENTINEL-2 LEVEL 1 PRODUCTS AND IMAGE PROCESSING PERFORMANCES

    OpenAIRE

    S. J. Baillarin; A. Meygret; C. Dechoz; B. Petrucci; S. Lacherade; T. Tremas; C. Isola; P. Martimort; F. Spoto

    2012-01-01

    In partnership with the European Commission and in the frame of the Global Monitoring for Environment and Security (GMES) program, the European Space Agency (ESA) is developing the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. While ensuring data continuity of former SPOT and LANDSAT multi-spectral missions, Sentinel-2 wil...

  6. ESA's Multi-mission Sentinel-1 Toolbox

    Science.gov (United States)

    Veci, Luis; Lu, Jun; Foumelis, Michael; Engdahl, Marcus

    2017-04-01

    The Sentinel-1 Toolbox is a new open source software for scientific learning, research and exploitation of the large archives of Sentinel and heritage missions. The Toolbox is based on the proven BEAM/NEST architecture inheriting all current NEST functionality including multi-mission support for most civilian satellite SAR missions. The project is funded through ESA's Scientific Exploitation of Operational Missions (SEOM). The Sentinel-1 Toolbox will strive to serve the SEOM mandate by providing leading-edge software to the science and application users in support of ESA's operational SAR mission as well as by educating and growing a SAR user community. The Toolbox consists of a collection of processing tools, data product readers and writers and a display and analysis application. A common architecture for all Sentinel Toolboxes is being jointly developed by Brockmann Consult, Array Systems Computing and C-S called the Sentinel Application Platform (SNAP). The SNAP architecture is ideal for Earth Observation processing and analysis due the following technological innovations: Extensibility, Portability, Modular Rich Client Platform, Generic EO Data Abstraction, Tiled Memory Management, and a Graph Processing Framework. The project has developed new tools for working with Sentinel-1 data in particular for working with the new Interferometric TOPSAR mode. TOPSAR Complex Coregistration and a complete Interferometric processing chain has been implemented for Sentinel-1 TOPSAR data. To accomplish this, a coregistration following the Spectral Diversity[4] method has been developed as well as special azimuth handling in the coherence, interferogram and spectral filter operators. The Toolbox includes reading of L0, L1 and L2 products in SAFE format, calibration and de-noising, slice product assembling, TOPSAR deburst and sub-swath merging, terrain flattening radiometric normalization, and visualization for L2 OCN products. The Toolbox also provides several new tools for

  7. A Vision-Aided 3D Path Teaching Method before Narrow Butt Joint Welding.

    Science.gov (United States)

    Zeng, Jinle; Chang, Baohua; Du, Dong; Peng, Guodong; Chang, Shuhe; Hong, Yuxiang; Wang, Li; Shan, Jiguo

    2017-05-11

    For better welding quality, accurate path teaching for actuators must be achieved before welding. Due to machining errors, assembly errors, deformations, etc., the actual groove position may be different from the predetermined path. Therefore, it is significant to recognize the actual groove position using machine vision methods and perform an accurate path teaching process. However, during the teaching process of a narrow butt joint, the existing machine vision methods may fail because of poor adaptability, low resolution, and lack of 3D information. This paper proposes a 3D path teaching method for narrow butt joint welding. This method obtains two kinds of visual information nearly at the same time, namely 2D pixel coordinates of the groove in uniform lighting condition and 3D point cloud data of the workpiece surface in cross-line laser lighting condition. The 3D position and pose between the welding torch and groove can be calculated after information fusion. The image resolution can reach 12.5 μm. Experiments are carried out at an actuator speed of 2300 mm/min and groove width of less than 0.1 mm. The results show that this method is suitable for groove recognition before narrow butt joint welding and can be applied in path teaching fields of 3D complex components.

  8. A Demonstration System for Capturing Geothermal Energy from Mine Waters beneath Butte, Montana

    Energy Technology Data Exchange (ETDEWEB)

    Blackketter, Donald [Montana Tech of the Univ. of Montana, Butte, MT (United States)

    2015-06-01

    Executive Summary An innovative 50-ton ground-source heat pump (GSHP) system was installed to provide space heating and cooling for a 56,000 square foot (5,200 square meter) building in Butte Montana, in conjunction with its heating and chiller systems. Butte is a location with winter conditions much colder than the national average. The GSHP uses flooded mine waters at 78F (25C) as the heat source and heat sink. The heat transfer performance and efficiency of the system were analyzed using data from January through July 2014. This analysis indicated that for typical winter conditions in Butte, Montana, the GSHP could deliver about 88% of the building’s annual heating needs. Compared with a baseline natural-gas/electric system, the system demonstrated at least 69% site energy savings, 38% source energy savings, 39% carbon dioxide emissions reduction, and a savings of $17,000 per year (40%) in utility costs. Assuming a $10,000 per ton cost for installing a production system, the payback period at natural gas costs of $9.63/MMBtu and electricity costs of $0.08/kWh would be in the range of 40 to 50 years. At higher utility prices, or lower installation costs, the payback period would obviously be reduced.

  9. Sentinel lymph node detection in canine oncological patients

    International Nuclear Information System (INIS)

    Balogh, L.; Andocs, G.; Mathe, D.

    2002-01-01

    Sentinel lymph node detection was investigated in dogs with spontaneously occurring tumours. In this pilot study, 24 client-owned spontaneously tumorous dogs presented for sentinel lymph node detection. A multiple method was used with a nuclear medicine technique (injection of 99mT c human serum albumin colloid) with scintigraphy and intraoperative guidance, and blue dye injection. Of the 35 lymph nodes histologically demonstrated to contain metastases, 34 (97%) were found by radioguided surgery, which means that one would have been missed in the intraoperative localisation process; 31 nodes (89%) were clearly visualised in the gamma camera images; only 27 (77%) were blue-stained by vital dye; a mere 8 lymph nodes (23%) were enlarged and therefore easily detectable by palpation. Data obtained from the harmless application of the sentinel node concept are useful for the radiopharmaceutist. The sentinel lymph node concept is well applicable in the veterinary clinic. (author)

  10. Gray-scale contrast-enhanced utrasonography in detecting sentinel lymph nodes: An animal study

    International Nuclear Information System (INIS)

    Wang Yuexiang; Cheng Zhigang; Li Junlai; Tang Jie

    2010-01-01

    Objective: To investigate the usefulness of gray-scale contrast-enhanced ultrasonography for detecting sentinel lymph nodes. Methods: Contrast-enhanced ultrasonography was performed in five normal dogs (four female and one male) after subcutaneous administration of a sonographic contrast agent (Sonovue, Bracco, Milan, Italy). Four distinct regions in each animal were examined. After contrast-enhanced ultrasonography, 0.8 ml of blue dye was injected into the same location as Sonovue and the sentinel lymph nodes were detected by surgical dissection. The findings of contrast-enhanced ultrasonography were compared with those of the blue dye. Results: Twenty-one sentinel lymph nodes were detected by contrast-enhanced ultrasonography while 23 were identified by blue dye with surgical dissection. Compared with the blue dye, the detection rate of enhanced ultrasonography for the sentinel lymph nodes is 91.3% (21/23). Two patterns of enhancement in the sentinel lymph nodes were observed: complete enhancement (5 sentinel lymph nodes) and partial enhancement (16 sentinel lymph nodes). The lymphatic channels were demonstrated as hyperechoic linear structures leading from the injection site and could be readily followed to their sentinel lymph nodes. Histopathologic examination showed proliferation of lymphatic follicles or lymphatic sinus in partial enhanced sentinel lymph nodes while normal lymphatic tissue was demonstrated in completely enhanced sentinel lymph nodes. Conclusions: Sonovue combined with gray-scale contrast-enhanced ultrasonography may provide a feasible method for detecting sentinel lymph nodes.

  11. Episodic Holocene eruption of the Salton Buttes rhyolites, California, from paleomagnetic, U-Th, and Ar/Ar dating

    Science.gov (United States)

    Wright, Heather M.; Vazquez, Jorge A.; Champion, Duane E.; Calvert, Andrew T.; Mangan, Margaret T.; Stelten, Mark E.; Cooper, Kari M.; Herzig, Charles; Schriener Jr., Alexander

    2015-01-01

    In the Salton Trough, CA, five rhyolite domes form the Salton Buttes: Mullet Island, Obsidian Butte, Rock Hill, North and South Red Hill, from oldest to youngest. Results presented here include 40Ar/39Ar anorthoclase ages, 238U-230Th zircon crystallization ages, and comparison of remanent paleomagnetic directions with the secular variation curve, which indicate that all domes are Holocene. 238U-230Th zircon crystallization ages are more precise than but within uncertainty of 40Ar/39Ar anorthoclase ages, suggesting that zircon crystallization proceeded until shortly before eruption in all cases except one. Remanent paleomagnetic directions require three eruption periods: (1) Mullet Island, (2) Obsidian Butte, and (3) Rock Hill, North Red Hill, and South Red Hill. Borehole cuttings logs document up to two shallow tephra layers. North and South Red Hills likely erupted within 100 years of each other, with a combined 238U-230Th zircon isochron age of: 2.83 ± 0.60 ka (2 sigma); paleomagnetic evidence suggests this age predates eruption by hundreds of years (1800 cal BP). Rock Hill erupted closely in time to these eruptions. The Obsidian Butte 238U-230Th isochron age (2.86 ± 0.96 ka) is nearly identical to the combined Red Hill age, but its Virtual Geomagnetic Pole position suggests a slightly older age. The age of aphyric Mullet Island dome is the least well constrained: zircon crystals are resorbed and the paleomagnetic direction is most distinct; possible Mullet Island ages include ca. 2300, 5900, 6900, and 7700 cal BP. Our results constrain the duration of Salton Buttes volcanism to between ca. 5900 and 500 years.

  12. The geology of Pine and Crater Buttes: Two basaltic constructs on the far eastern Snake River Plain

    Science.gov (United States)

    Mazierski, Paul F.; King, John S.

    1987-01-01

    The emplacement history and petrochemical evolution of the volcanics associated with Pine Butte, Crater Butte, and other nearby vents are developed and described. Four major vents were identified in the study area and their associated eruptive products were mapped. All of the vents show a marked physical elongation or linear orientation coincident with the observed rift set. Planetary exploration has revealed the importance of volcanic processes in the genesis and modification of extraterrestrial surfaces. Interpretation of surface features has identified plains-type basaltic volcanism in various mare regions of the Moon and the volcanic provinces of Mars. Identification of these areas with features that appear analogous to those observed in the Pine Butte area suggests similar styles of eruption and mode of emplacement. Such terrestrial analogies serve as a method to interpret the evolution of volcanic planetary surfaces on the inner planets.

  13. Sentinel lymph node biopsy: An audit of intraoperative assessment ...

    African Journals Online (AJOL)

    2015-07-02

    Jul 2, 2015 ... Sentinel lymph node biopsy: An audit of ... cytotechnology service ... To audit results from intraoperative assessment of sentinel lymph node ..... out, and turnaround time in gynecologic cytology quality assurance: Findings.

  14. A Semi-analytical model for creep life prediction of butt-welded joints in cylindrical vessels

    International Nuclear Information System (INIS)

    Zarrabi, K.

    2001-01-01

    There have been many investigations on the life assessment of high temperature weldments used in cylindrical pressure vessels, pipes and tubes over the last two decades or so. But to the author's knowledge, currently, there exists no practical, economical and relatively accurate model for creep life assessment of butt-welded joints in cylindrical pressure vessels. This paper describes a semi-analytical and economical model for creep life assessment of butt-welded joints. The first stage of the development of the model is described where the model takes into account the material discontinuities at the welded joint only. The development of the model to include other factors such as geometrical stress concentrations, residual stresses, etc will be reported separately. It has been shown that the proposed model can estimate the redistributions of stresses in the weld and Haz with an error of less than 4%. It has also been shown that the proposed model can conservatively predict the creep life of a butt-welded joint with an error of less than 16%

  15. Sentinel Lymph Node Biopsy in Breast Cancer: Predictors of Axillary and Non-Sentinel Lymph Node Involvement

    Directory of Open Access Journals (Sweden)

    Hakan Postacı

    2013-12-01

    Full Text Available Background: Sentinel lymph node biopsy is a standard method for the evaluation of axillary status in patients with T1-2N0M0 breast cancers. Aims: To determine the prognostic significance of primary tumour-related clinico-histopathological factors on axillary and non-sentinel lymph node involvement of patients who underwent sentinel lymph node biopsy. Study design: Retrospective clinical study. Methods: In the present study, 157 sentinel lymph node biopsies were performed in 151 consecutive patients with early stage breast cancer between June 2008 and December 2011. Results: Successful lymphatic mapping was obtained in 157 of 158 procedures (99.4%. The incidence of larger tumour size (2.543±1.21 vs. 1.974±1.04, lymphatic vessel invasion (70.6% vs. 29.4%, blood vessel invasion (84.2% vs. 15.8%, and invasive lobular carcinoma subtype (72.7% vs. 27.3% were statistically significantly higher in patients with positive SLNs. Logistic stepwise regression analysis disclosed tumour size (odds ratio: 1.51, p=0.0021 and lymphatic vessel invasion (odds ratio: 4.68, p=0.001 as significant primary tumour-related prognostic determinants of SLN metastasis. Conclusion: A close relationship was identified between tumour size and lymphatic vessel invasion of the primary tumour and axillary lymph node involvement. However, the positive predictive value of these two independent variables is low and there is no compelling evidence to recommend their use in routine clinical practice.

  16. FOREST AREA DERIVATION FROM SENTINEL-1 DATA

    Directory of Open Access Journals (Sweden)

    A. Dostálová

    2016-06-01

    Full Text Available The recently launched Sentinel-1A provides the high resolution Synthetic Aperture Radar (SAR data with very high temporal coverage over large parts of European continent. Short revisit time and dual polarization availability supports its usability for forestry applications. The following study presents an analysis of the potential of the multi-temporal dual-polarization Sentinel-1A data for the forest area derivation using the standard methods based on Otsu thresholding and K-means clustering. Sentinel-1 data collected in winter season 2014-2015 over a test area in eastern Austria were used to derive forest area mask with spatial resolution of 10m and minimum mapping unit of 500 m2. The validation with reference forest mask derived from airborne full-waveform laser scanning data revealed overall accuracy of 92 % and kappa statistics of 0.81. Even better results can be achieved when using external mask for urban areas, which might be misclassified as forests when using the introduced approach based on SAR data only. The Sentinel-1 data and the described methods are well suited for forest change detection between consecutive years.

  17. Intraoperative examination of sentinel lymph nodes using scrape ...

    African Journals Online (AJOL)

    Background. In breast cancer, sentinel lymph node biopsy (SLNB) is widely used to assess the axilla when the nodes appear normal on palpation and ultrasonography. When the sentinel lymph nodes (SLNs) are negative, no further dissection is required. Surgical dissection or radiotherapy of the axilla is indicated for ...

  18. Intraoperative examination of sentinel lymph nodes using scrape ...

    African Journals Online (AJOL)

    2014-08-03

    Aug 3, 2014 ... Background. In breast cancer, sentinel lymph node biopsy (SLNB) is widely used to assess the axilla when the nodes appear normal on palpation and ultrasonography. When the sentinel lymph nodes (SLNs) are negative, no further dissection is required. Surgical dissection or radiotherapy of the axilla is ...

  19. Modeling and control of a DC upset resistance butt welding process

    NARCIS (Netherlands)

    Naus, G.J.L.; Meulenberg, R.; Molengraft, van de M.J.G.

    2007-01-01

    This paper presents the analysis and synthesis of modeling and control of the DC upset resistance butt welding process used in rim production lines. A new control strategy is developed, enabling active control of the welding seam temperature and the upset size. As a result, set-up times and energy

  20. A new method to butt weld pipes with laser at different angles

    International Nuclear Information System (INIS)

    Gualini, M.M.S.

    1999-01-01

    Laser butt welding of pipes at different angles may be cumbersome and may require very expensive tooling. The pipe size may not allow using the laser for large volume throughputs. We propose a rotary optical head composed by an adjustable focus lens system and two reflecting mirrors. The laser beam is bent at 90 deg. C. so that weld can be performed inwards outwards. The optic head design compensates the rotary backlash and vibrations, like a penta prism thus ensuring a perfect follow up of the weld track. The optic head can be inclined at 45 deg. C. to laser butt weld pipe each other at 90 deg. C. In this case the laser beam focus position is computer controlled in order to keep the focus point always on the elliptical weld profile. The paper covers theoretical and practical aspects of the proposed device. (author)

  1. Sentinel lymph node biopsy in endometrial cancer-Feasibility, safety and lymphatic complications.

    Science.gov (United States)

    Geppert, Barbara; Lönnerfors, Céline; Bollino, Michele; Persson, Jan

    2018-03-01

    To compare the rate of lymphatic complications in women with endometrial cancer undergoing sentinel lymph node biopsy versus a full pelvic and infrarenal paraaortic lymphadenectomy, and to examine the overall feasibility and safety of the former. A prospective study of 188 patients with endometrial cancer planned for robotic surgery. Indocyanine green was used to identify the sentinel lymph nodes. In low-risk patients the lymphadenectomy was restricted to removal of sentinel lymph nodes whereas in high-risk patients also a full lymphadenectomy was performed. The impact of the extent of the lymphadenectomy on the rate of complications was evaluated. The bilateral detection rate of sentinel lymph nodes was 96% after cervical tracer injection. No intraoperative complication was associated with the sentinel lymph node biopsy per se. Compared with hysterectomy alone, the additional average operative time for removal of sentinel lymph nodes was 33min whereas 91min were saved compared with a full pelvic and paraaortic lymphadenectomy. Sentinel lymph node biopsy alone resulted in a lower incidence of leg lymphedema than infrarenal paraaortic and pelvic lymphadenectomy (1.3% vs 18.1%, p=0.0003). The high feasibility, the absence of intraoperative complications and the low risk of lymphatic complications supports implementing detection of sentinel lymph nodes in low-risk endometrial cancer patients. Given that available preliminary data on sensitivity and false negative rates in high-risk patients are confirmed in further studies, we also believe that the reduction in lymphatic complications and operative time strongly motivates the sentinel lymph node concept in high-risk endometrial cancer. Copyright © 2017. Published by Elsevier Inc.

  2. Lymphoscintigraphic Identification of Sentinel Nodes in Malignant Melanoma

    International Nuclear Information System (INIS)

    Andries, G.; Dindelegan, G.; Ciule, Larisa; Cosgarea, Rodica; Cobzac, Gh.

    2006-01-01

    Full text: The most important prognostic factor in malignant melanoma is the presence or absence of metastasis in lymph nodes. It has been demonstrated the orderly progression of different types of tumours. Sentinel lymph node identification is done lymphoscintigraphically, followed by surgical excision and morpho pathological exam. Material and methods: We studied 33 patients with malignant melanoma (age 26-84 years) divided in 2 subgroups: group A without gamma probe (18 patients) and group B with gamma probe (15 patients). The lymphoscintigraphy (LS) was performed with a totally dose of 20-30 MBq of 99mTc-nanocoloid (Amersham) injected peritumoral or pericicatriceal in 4-6 points in volume of 0,1-0,2 ml per point. Acquisition was performed dynamic for 10-15 min and static at 30-60 min p.i. on perpendicular projections. Patent blue dye was injected prior surgery. In group A has performed sentinel node excision (13 patients) or ELND (4), one patient has died before surgery. In group B sentinel nodes were surgically excised with gamma probe and ELND was performed in patients with positive lymph nodes. Histopathologically, sentinel nodes were stained with HE and in 6 cases with HMB45. Results: In group A we identified the sentinel nodes scintigraphically in all patients (median 1,83±-1,50 nodes, range 1-7). Surgically with PBD were identified 1,69±1,18 sentinel nodes, in 2 patients the SN lymphadenectomy was negative. All nodes excised were histopathologically negative, but in 4 patients loco-regional recurrence or distant metastasis developed. In group B we identified scintigraphically 33 SNs (median 2,20±1,37 nodes, range 1-5) and 4 in transit nodes in 14 patients, 24 of them being blue dye positive (80%), in 1 patient LS was negative. With gamma probe surgeon excised 39 radioactive nodes and 1 SN blue dye positive only, 10 of them being histopathologically positive (25% node metastasis). No metastasis were identified after ELND in patients with positive SNs

  3. SENTINEL-1 RESULTS: SEA ICE OPERATIONAL MONITORING

    DEFF Research Database (Denmark)

    Toudal Pedersen, Leif; Saldo, Roberto; Fenger-Nielsen, Rasmus

    2015-01-01

    In the present paper we demonstrate the capabilities of the Sentinel-1 SAR data for operational sea-ice and iceberg monitoring. Most of the examples are drawn from the Copernicus Marine Environmental Monitoring Service (CMEMS) production.......In the present paper we demonstrate the capabilities of the Sentinel-1 SAR data for operational sea-ice and iceberg monitoring. Most of the examples are drawn from the Copernicus Marine Environmental Monitoring Service (CMEMS) production....

  4. The role of sentinel node detection techniques in vulvar and cervival cancer

    International Nuclear Information System (INIS)

    Wydra, D.; Sawicki, S.; Emerich, J.; Romanowicz, G.

    2002-01-01

    The sentinel node is the first lymph node that receives the lymph drainage from the primary tumour. The pathological status of the sentinel node should reflect the histopathology of the entire regional lymph drainage area - both vulvar and cervical cancer spread through the lymphatic system. In gynaecological oncology recent studies have confirmed the utility of the sentinel node concept in vulvar and cervical cancer. Three techniques for sentinel node localisation are available. The preoperative lymphoscintigraphy and intraoperative handheld gamma probe detection require the administration of the technetium-99m-labelled colloid around the tumour. The other method is based on the injection of the patent blue dye - during the surgery of the sentinel node because of the dye uptake becomes visible. Following detection, the sentinel lymph node can be removed separately and assessed with ultrastaging and immunohistochemical staining. In the early stages of vulvar and cervical cancer the lymph nodes metastases rate is relatively low - in most cases lymphadenectomy is not necessary. The determination of the regional lymph nodes' pathological status may limit the extent of the surgical treatment. The sentinel node detection rate is relatively high and depends on the applied technique. This technique may play an important role in the treatment of vulvar and cervical cancer. This paper describes the details of sentinel node identification and reviews the literature. (author)

  5. Radionavigated detection of sentinel nodes in breast carcinoma--first experiences of our department.

    Science.gov (United States)

    Duchaj, B; Chvalny, P; Vesely, J; Makaiova, I; Durdik, S; Straka, V; Palaj, J; Procka, V; Aksamitova, K; Skraskova, S; Banki, P; Kovacova, S; Galbavy, S

    2010-01-01

    Biopsy and histological evaluation of sentinel lymphatic node limits the axillary node dissection only in cases of positive histological finding and decreases the occurrence of postoperative complications related to the axillary node dissection. We used radiotracer SentiScint, Medi-Radiopharma Ltd, Hungary and preoperatively administered blue dye--Blue Patenté V, Guebert, Aulnay-Sous-Bios, France. 11 (18%) patients were subdued to deep peritimorous application of radiotracer, 10 (16.4%) to sub/intradermal application over the lesions and n 40 (65.6%) patients the application was sub/intradermal and periareolar. The patients underwent an operation protocol of corresponding quadrantectomy, radionavigated blue-dye sentinel node biopsy and axillary dissection. From May 2006 to June 2008, we examined 61 patients with breast carcinoma. They underwent radionavigated and blue-dye sentinel node biopsy. We detected 57 (93.4%) sentinel nodes with preoperative scintigraphy, of which only 51 (83.6%) were detected peroperatively and underwent histological evaluation. In six (9.8%) cases, the "frozen cut" histology of the primary lesion had shown a benign lesion; hence no sentinel node biopsy or axillary disection was performed. 12 (19.7%) of 51 histologically evaluated sentinel nodes had metastatic invasion. We retrospectively compared the histological fund in sentinel and axillary nodes in patients with metastatic sentinel nodes. In 6 (16.6%) cases, the sentinel node was positive of metastatic invasion but axillary nodes were histologically negative, in 6 (16.6%) cases the sentinel node and axillary nodes were positive for metastatic invasion. We observed falsely negative findings in 3 (8.3%) patients with negative histological fund in the sentinel node, but positive axillary nodes (Tab. 3, Fig. 2, Ref. 11). Full Text (Free, PDF) www.bmj.sk.

  6. SENTINEL-2 Services Library - efficient way for exploration and exploitation of EO data

    Science.gov (United States)

    Milcinski, Grega; Batic, Matej; Kadunc, Miha; Kolaric, Primoz; Mocnik, Rok; Repse, marko

    2017-04-01

    With more than 1.5 million scenes available covering over 11 billion sq. kilometers of area and containing half a quadrillion of pixels, Sentinel-2 is becoming one of the most important MSI datasets in the world. However, the vast amount of data makes it difficult to work with. This is certainly an important reason, why the number of Sentinel based applications is not as high as it could be at this point. We will present a Copernicus Award [1] winning service for archiving, processing and distribution of Sentinel data, Sentinel Hub [2]. It makes it easy for anyone to tap into global Sentinel archive and exploit its rich multi-sensor data to observe changes in the land. We will demonstrate, how one is able not just to observe imagery all over the world but also to create its own statistical analysis in a matter of seconds, performing comparison of different sensors through various time segments. The result can be immediately observed in any GIS tool or exported as a raster file for post-processing. All of these actions can be performed on a full, worldwide, S-2 archive (multi-temporal and multi-spectral). To demonstrate the technology, we created a publicly accessible web application, called "Sentinel Playground" [3], which makes it possible to query Sentinel-2 data anywhere in the world, and experts-oriented tool "EO Browser" [4], where it is also possible to observe land changes through longer period by using historical Landsat data as well. [1] http://www.copernicus-masters.com/index.php?anzeige=press-2016-03.html [2] http://www.sentinel-hub.com [3] http://apps.sentinel-hub.com/sentinel-playground/ [4] http://apps.eocloud.sentinel-hub.com/eo-browser/

  7. Teacher's Guide to Architectural Styles. Skinner's Butte Historical District. Revised Edition.

    Science.gov (United States)

    Bauer, Mary; Neimand, Hahn

    This document is a teacher's guide to the historic buildings of Eugene, Oregon. Eighteen buildings in the Skinner's Butte Historical District are highlighted, including the U.S. Post Office, the Eagles Building, the Lane Hotel, the Oregon Electric Depot, the Southern Pacific Railroad Depot, and several houses. For each structure there is a brief…

  8. Sentinel lymph node biopsy in breast cancer and melanoma

    NARCIS (Netherlands)

    Doting, Meintje Hylkje Edwina

    2007-01-01

    Summary and conclusions In the introduction, a short overview of the development of the sentinel lymph node biopsy concept is presented. In addition to melanoma and breast cancer, the usefulness of sentinel lymph node biopsy as a surgical assessment method for squamous cell carcinoma of penis and

  9. Sentinel nodes identified by computed tomography-lymphography accurately stage the axilla in patients with breast cancer

    International Nuclear Information System (INIS)

    Motomura, Kazuyoshi; Sumino, Hiroshi; Noguchi, Atsushi; Horinouchi, Takashi; Nakanishi, Katsuyuki

    2013-01-01

    Sentinel node biopsy often results in the identification and removal of multiple nodes as sentinel nodes, although most of these nodes could be non-sentinel nodes. This study investigated whether computed tomography-lymphography (CT-LG) can distinguish sentinel nodes from non-sentinel nodes and whether sentinel nodes identified by CT-LG can accurately stage the axilla in patients with breast cancer. This study included 184 patients with breast cancer and clinically negative nodes. Contrast agent was injected interstitially. The location of sentinel nodes was marked on the skin surface using a CT laser light navigator system. Lymph nodes located just under the marks were first removed as sentinel nodes. Then, all dyed nodes or all hot nodes were removed. The mean number of sentinel nodes identified by CT-LG was significantly lower than that of dyed and/or hot nodes removed (1.1 vs 1.8, p <0.0001). Twenty-three (12.5%) patients had ≥2 sentinel nodes identified by CT-LG removed, whereas 94 (51.1%) of patients had ≥2 dyed and/or hot nodes removed (p <0.0001). Pathological evaluation demonstrated that 47 (25.5%) of 184 patients had metastasis to at least one node. All 47 patients demonstrated metastases to at least one of the sentinel nodes identified by CT-LG. CT-LG can distinguish sentinel nodes from non-sentinel nodes, and sentinel nodes identified by CT-LG can accurately stage the axilla in patients with breast cancer. Successful identification of sentinel nodes using CT-LG may facilitate image-based diagnosis of metastasis, possibly leading to the omission of sentinel node biopsy

  10. Joint Sentinel-1 and SMAP data assimilation to improve soil moisture estimates

    Science.gov (United States)

    Lievens, H.; Reichle, R. H.; Liu, Q.; De Lannoy, G.; Dunbar, R. S.; Kim, S.; Das, N. N.; Cosh, M. H.; Walker, J. P.; Wagner, W.

    2017-12-01

    SMAP (Soil Moisture Active and Passive) radiometer observations at 40 km resolution are routinely assimilated into the NASA Catchment Land Surface Model (CLSM) to generate the SMAP Level 4 Soil Moisture product. The use of C-band radar backscatter observations from Sentinel-1 has the potential to add value to the radiance assimilation by increasing the level of spatial detail. The specifications of Sentinel-1 are appealing, particularly its high spatial resolution (5 by 20 m in interferometric wide swath mode) and frequent revisit time (6 day repeat cycle for the Sentinel-1A and Sentinel-1B constellation). However, the shorter wavelength of Sentinel-1 observations implies less sensitivity to soil moisture. This study investigates the value of Sentinel-1 data for hydrologic simulations by assimilating the radar observations into CLSM, either separately from or simultaneously with SMAP radiometer observations. To facilitate the assimilation of the radar observations, CLSM is coupled to the water cloud model, simulating the radar backscatter as observed by Sentinel-1. The innovations, i.e. differences between observations and simulations, are converted into increments to the model soil moisture state through an Ensemble Kalman Filter. The assimilation impact is assessed by comparing 3-hourly, 9 km surface and root-zone soil moisture simulations with in situ measurements from 9 km SMAP core validation sites and sparse networks, from May 2015 to 2017. The Sentinel-1 assimilation consistently improves surface soil moisture, whereas root-zone impacts are mostly neutral. Relatively larger improvements are obtained from SMAP assimilation. The joint assimilation of SMAP and Sentinel-1 observations performs best, demonstrating the complementary value of radar and radiometer observations.

  11. The Sentinel-4 detectors: architecture and performance

    Science.gov (United States)

    Skegg, Michael P.; Hermsen, Markus; Hohn, Rüdiger; Williges, Christian; Woffinden, Charles; Levillain, Yves; Reulke, Ralf

    2017-09-01

    The Sentinel-4 instrument is an imaging spectrometer, developed by Airbus under ESA contract in the frame of the joint European Union (EU)/ESA COPERNICUS program. SENTINEL-4 will provide accurate measurements of trace gases from geostationary orbit, including key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, formaldehyde, as well as aerosol and cloud properties. Key to achieving these atmospheric measurements are the two CCD detectors, covering the wavelengths in the ranges 305 nm to 500 nm (UVVIS) and 750 to 775 nm (NIR) respectively. The paper describes the architecture, and operation of these two CCD detectors, which have an unusually high full-well capacity and a very specific architecture and read-out sequence to match the requirements of the Sentinel- 4 instrument. The key performance aspects and their verification through measurement are presented, with a focus on an unusual, bi-modal dark signal generation rate observed during test.

  12. Vision and spectroscopic sensing for joint tracing in narrow gap laser butt welding

    Science.gov (United States)

    Nilsen, Morgan; Sikström, Fredrik; Christiansson, Anna-Karin; Ancona, Antonio

    2017-11-01

    The automated laser beam butt welding process is sensitive to positioning the laser beam with respect to the joint because a small offset may result in detrimental lack of sidewall fusion. This problem is even more pronounced in case of narrow gap butt welding, where most of the commercial automatic joint tracing systems fail to detect the exact position and size of the gap. In this work, a dual vision and spectroscopic sensing approach is proposed to trace narrow gap butt joints during laser welding. The system consists of a camera with suitable illumination and matched optical filters and a fast miniature spectrometer. An image processing algorithm of the camera recordings has been developed in order to estimate the laser spot position relative to the joint position. The spectral emissions from the laser induced plasma plume have been acquired by the spectrometer, and based on the measurements of the intensities of selected lines of the spectrum, the electron temperature signal has been calculated and correlated to variations of process conditions. The individual performances of these two systems have been experimentally investigated and evaluated offline by data from several welding experiments, where artificial abrupt as well as gradual deviations of the laser beam out of the joint were produced. Results indicate that a combination of the information provided by the vision and spectroscopic systems is beneficial for development of a hybrid sensing system for joint tracing.

  13. FIRE HAZARDS ANALYSIS - BUSTED BUTTE

    International Nuclear Information System (INIS)

    Longwell, R.; Keifer, J.; Goodin, S.

    2001-01-01

    The purpose of this fire hazards analysis (FHA) is to assess the risk from fire within individual fire areas at the Busted Butte Test Facility and to ascertain whether the DOE fire safety objectives are met. The objective, identified in DOE Order 420.1, Section 4.2, is to establish requirements for a comprehensive fire and related hazards protection program for facilities sufficient to minimize the potential for: (1) The occurrence of a fire related event. (2) A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of employees. (3) Vital DOE programs suffering unacceptable interruptions as a result of fire and related hazards. (4) Property losses from a fire and related events exceeding limits established by DOE. Critical process controls and safety class systems being damaged as a result of a fire and related events

  14. U.S. Geological Survey distribution of European Space Agency's Sentinel-2 data

    Science.gov (United States)

    Pieschke, Renee L.

    2017-03-31

    A partnership established between the European Space Agency (ESA) and the U.S. Geological Survey (USGS) allows for USGS storage and redistribution of images acquired by the MultiSpectral Instrument (MSI) on the European Union's Sentinel-2 satellite mission. The MSI data are acquired from a pair of satellites, Sentinel-2A and Sentinel-2B, which are part of a larger set of ESA missions focusing on different aspects of Earth observation. The primary purpose of the Sentinel-2 series is to collect multispectral imagery over the Earth’s land surfaces, large islands, and inland and coastal waters. Sentinel-2A was launched in 2015 and Sentinel-2B launched in 2017.The collaborative effort between ESA and USGS provides for public access and redistribution of global acquisitions of Sentinel-2 data at no cost, which allows users to download the MSI imagery from USGS access systems such as Earth- Explorer, in addition to the ESA Sentinels Scientific Data Hub. The MSI sensor acquires 13 spectral bands that are highly complementary to data acquired by the USGS Landsat 8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+). The product options from USGS include a Full-Resolution Browse (FRB) image product generated by USGS, along with a 100-kilometer (km) by 100-km tile-based Level-1C top-of-atmosphere (TOA) reflectance product that is very similar (but not identical) to the currently (2017) distributed ESA Level 1C product.

  15. Citrullus lanatus `Sentinel' (Watermelon) Extract Reduces Atherosclerosis in LDL Receptor Deficient Mice

    Science.gov (United States)

    Poduri, Aruna; Rateri, Debra L.; Saha, Shubin K.; Saha, Sibu; Daugherty, Alan

    2012-01-01

    Watermelon (Citrullus lanatus or C. lanatus) has many potentially bioactive compounds including citrulline, which may influence atherosclerosis. In this study, we determined the effects of C. lanatus, provided as an extract of the cultivar `sentinel', on hypercholesterolemia-induced atherosclerosis in mice. Male LDL receptor deficient mice at 8 weeks old were given either C. lanatus `sentinel' extract (2% vol/vol; n=10) or a mixture of matching carbohydrates (2% vol/vol; n=8) as the control in drinking water, while fed a saturated fat-enriched diet for 12 weeks ad libitum. Mice consuming C. lanatus `sentinel' extract had significantly increased plasma citrulline concentrations. Systolic blood pressure was comparable between the two groups. Consumption of C. lanatus `sentinel' extract led to lower body weight and fat mass without influencing lean mass. There were no differences in food and water intake, and urine output between the two groups. C. lanatus `sentinel' extract administration decreased plasma cholesterol concentrations that were attributed to reductions of intermediate/low density lipoprotein cholesterol. Plasma concentrations of MCP-1 and IFN-γ were decreased and IL-10 increased in mice consuming C. lanatus `sentinel' extract. Intake of C. lanatus `sentinel' extract resulted in reductions of atherosclerosis in both aortic arch and thoracic regions. In conclusion, consumption of C. lanatus `sentinel' extract led to reduced body weight gain, decreased plasma cholesterol concentrations, improved homeostasis of pro- and anti-inflammatory cytokines, and attenuated development of atherosclerosis without affecting systolic blood pressure in hypercholesterolemic mice. PMID:22902326

  16. Tidal Creek Sentinel Habitat Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Ecological Research, Assessment and Prediction's Tidal Creeks: Sentinel Habitat Database was developed to support the National Oceanic and Atmospheric...

  17. Detection of induced seismicity effects on ground surface using data from Sentinel 1A/1B satellites

    Science.gov (United States)

    Milczarek, W.

    2017-12-01

    Induced seismicity is the result of human activity and manifests itself in the form of shock and vibration of the ground surface. One of the most common factors causing the occurrence of induced shocks is underground mining activity. Sufficiently strong high-energy shocks may cause displacements of the ground surface. This type of shocks can have a significant impact on buildings and infrastructure. Assessment of the size and influence of induced seismicity on the ground surface is one of the major problems associated with mining activity. In Poland (Central Eastern Europe) induced seismicity occurs in the area of hard coal mining in the Upper Silesian Coal Basin and in the area of the Legnica - Głogów Copper Basin.The study presents an assessment of the use of satellite radar data (SAR) for the detection influence of induced seismicity in mining regions. Selected induced shocks from the period 2015- 2017 which occurred in the Upper Silesian Coal Basin and the Legnica - Głogów Copper Basin areas have been analyzed. In the calculations SAR data from the Sentinel 1A and Sentinel 1B satellites have been used. The results indicate the possibility of quickly and accurate detection of ground surface displacements after an induced shock. The results of SAR data processing were compared with the results from geodetic measurements. It has been shown that SAR data can be used to detect ground surface displacements on the relative small regions.

  18. Roles of preoperative lymphoscintigraphy for sentinel lymph node biopsy in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xiao; Liu Juanjuan; Wang Yongsheng; Wang Lei; Yang Guoren; Zhou Zhengbo; Li Yongqing; Liu Yanbing; Li Taiyu

    2010-01-01

    The objective of this study was to evaluate roles of preoperative lymphoscintigraphy for sentinel lymph node biopsy in breast cancer patients. Five hundred and sixty-five consecutive breast cancer patients were prospectively randomized into groups with or without preoperative lymphoscintigraphy. In a group with lymphoscintigraphy, 238 patients had sentinel lymph nodes spotted in lymphoscintigram. The visualization of sentinel lymph nodes in lymphoscintigram was not associated with patients' age, primary tumor size and location, histopathologic type and time interval from injection of radiocolloid to lymphoscintigraphy. However, patients with axillary metastasis had a lower identification rate of sentinel lymph nodes by lymphoscintigraphy than those without metastasis (P=0.003). The identification rate of axillary sentinel lymph nodes was 99.3% in the group and the rate was similar whether there was sentinel lymph nodes spotted in axillary in lymphoscintigram or not (99.6% vs. 98.1%, P=0.327). The false-negative rate in this group was 4.2%. While in a group without lymphoscintigraphy, the identification rate and the false-negative rate were 99.6% and 4.8%, respectively. There was no significant difference between the two groups in the identification rate of axillary sentinel lymph nodes (P=0.594) and in the false-negative rate (P=1.00). Preoperative lymphoscintigraphy could neither improve the identification rate nor reduce the false-negative rate of breast cancer sentinel lymph node biopsy, and it is not necessary for sentinel lymph node biopsy in breast cancer patients. (author)

  19. Sentinel-5: the new generation European operational atmospheric chemistry mission in polar orbit

    Science.gov (United States)

    Pérez Albiñana, Abelardo; Erdmann, Matthias; Wright, Norrie; Martin, Didier; Melf, Markus; Bartsch, Peter; Seefelder, Wolfgang

    2017-08-01

    Sentinel-5 is an Earth Observation instrument to be flown on the Metop Second Generation (Metop-SG) satellites with the fundamental objective of monitoring atmospheric composition from polar orbit. The Sentinel-5 instrument consists of five spectrometers to measure the solar spectral radiance backscattered by the earth atmosphere in five bands within the UV (270nm) to SWIR (2385nm) spectral range. Data provided by Sentinel-5 will allow obtaining the distribution of important atmospheric constituents such as ozone, on a global daily basis and at a finer spatial resolution than its precursor instruments on the first generation of Metop satellites. The launch of the first Metop-SG satellite is foreseen for 2021. The Sentinel-5 instrument is being developed by Airbus DS under contract to the European Space Agency. The Sentinel-5 mission is part of the Space Component of the Copernicus programme, a joint initiative by ESA, EUMETSAT and the European Commission. The Preliminary Design Review (PDR) for the Sentinel-5 development was successfully completed in 2015. This paper provides a description of the Sentinel-5 instrument design and data calibration.

  20. The Sentinel-1 Mission: New Opportunities for Ice Sheet Observations

    Directory of Open Access Journals (Sweden)

    Thomas Nagler

    2015-07-01

    Full Text Available The Sentinel satellite constellation series, developed by the European Space Agency, represents the dedicated space component of the European Copernicus program, committed to long-term operational services in a wide range of application domains. Here, we address the potential of the Sentinel-1 mission for mapping and monitoring the surface velocity of glaciers and ice sheets. We present an ice velocity map of Greenland, derived from synthetic aperture radar (SAR data acquired in winter 2015 by Sentinel-1A, the first satellite of the Copernicus program in orbit. The map is assembled from about 900 SAR scenes acquired in Interferometric Wide swath (IW mode, applying the offset tracking technique. We discuss special features of IW mode data, describe the procedures for producing ice velocity maps, and assess the uncertainty of the ice motion product. We compare the Sentinel-1 ice motion product with velocity maps derived from high resolution SAR data of the TerraSAR-X mission and from PALSAR data. Beyond supporting operational services, the Sentinel-1 mission offers enhanced capabilities for comprehensive and long-term observation of key climate variables, such as the motion of ice masses.

  1. Citrullus lanatus 'sentinel' (watermelon) extract reduces atherosclerosis in LDL receptor-deficient mice.

    Science.gov (United States)

    Poduri, Aruna; Rateri, Debra L; Saha, Shubin K; Saha, Sibu; Daugherty, Alan

    2013-05-01

    Watermelon (Citrullus lanatus or C. lanatus) has many potentially bioactive compounds including citrulline, which may influence atherosclerosis. In this study, we determined the effects of C. lanatus, provided as an extract of the cultivar 'sentinel,' on hypercholesterolemia-induced atherosclerosis in mice. Male low-density lipoprotein receptor-deficient mice at 8 weeks old were given either C. lanatus 'sentinel' extract (2% vol/vol; n=10) or a mixture of matching carbohydrates (2% vol/vol; n=8) as the control in drinking water while being fed a saturated fat-enriched diet for 12 weeks ad libitum. Mice consuming C. lanatus 'sentinel' extract had significantly increased plasma citrulline concentrations. Systolic blood pressure was comparable between the two groups. Consumption of C. lanatus 'sentinel' extract led to lower body weight and fat mass without influencing lean mass. There were no differences in food and water intake and in urine output between the two groups. C. lanatus 'sentinel' extract administration decreased plasma cholesterol concentrations that were attributed to reductions of intermediate-/low-density lipoprotein cholesterol. Plasma concentrations of monocyte chemoattractant protein-1 and interferon-gamma were decreased and those of interleukin-10 were increased in mice consuming C. lanatus 'sentinel' extract. Intake of C. lanatus 'sentinel' extract resulted in reductions of atherosclerosis in both aortic arch and thoracic regions. In conclusion, consumption of C. lanatus 'sentinel' extract led to reduced body weight gain, decreased plasma cholesterol concentrations, improved homeostasis of pro- and anti-inflammatory cytokines, and attenuated development of atherosclerosis without affecting systolic blood pressure in hypercholesterolemic mice. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Sentinel lymph nodes in cancer of the oral cavity

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Christensen, Rikke Kølby; Sørensen, Jens Ahm

    2007-01-01

    when compared with (B) step-sectioning and immunostaining of the entire sentinel lymph node at 250 microM levels. METHODS: Forty patients with T1/T2 cN0 oral cancer were enrolled. Three patients were excluded. In one patient no sentinel lymph node was identified. The remaining two had unidentified...

  3. VERIFICATION OF THE SENTINEL-4 FOCAL PLANE SUBSYSTEM

    Directory of Open Access Journals (Sweden)

    C. Williges

    2017-05-01

    Full Text Available The Sentinel-4 payload is a multi-spectral camera system which is designed to monitor atmospheric conditions over Europe. The German Aerospace Center (DLR in Berlin, Germany conducted the verification campaign of the Focal Plane Subsystem (FPS on behalf of Airbus Defense and Space GmbH, Ottobrunn, Germany. The FPS consists, inter alia, of two Focal Plane Assemblies (FPAs, one for the UV-VIS spectral range (305 nm … 500 nm, the second for NIR (750 nm … 775 nm. In this publication, we will present in detail the opto-mechanical laboratory set-up of the verification campaign of the Sentinel-4 Qualification Model (QM which will also be used for the upcoming Flight Model (FM verification. The test campaign consists mainly of radiometric tests performed with an integrating sphere as homogenous light source. The FPAs have mainly to be operated at 215 K ± 5 K, making it necessary to exploit a thermal vacuum chamber (TVC for the test accomplishment. This publication focuses on the challenge to remotely illuminate both Sentinel-4 detectors as well as a reference detector homogeneously over a distance of approximately 1 m from outside the TVC. Furthermore selected test analyses and results will be presented, showing that the Sentinel-4 FPS meets specifications.

  4. Sentinel lymph node mapping in melanoma with technetium-99m dextran.

    Science.gov (United States)

    Neubauer, S; Mena, I; Iglesis, R; Schwartz, R; Acevedo, J C; Leon, A; Gomez, L

    2001-06-01

    The aim of this work is to evaluate the capability of Tc99m B Dextran as a lymphoscintigraphic agent in the detection of the sentinel node in skin lesions. Forty-one patients with melanomas (39) and Merkel cell tumors (2) had perilesional intradermal injection of Tc99m-Dextran 2 hours before surgery. Serial gamma camera images and a handheld gamma probe were used to direct sentinel node biopsy. In 39/41 patients, lymph channels and 52 sentinel nodes (one to three sentinel nodes/patient) could be visualized. In one patient, with a dorsal melanoma, no lymph channels or lymph nodes could be demonstrated on the images and only minimal radioactivity was found in the regional nodes with the probe. Another patient with a facial lesion failed to demonstrate lymph channels or nodes. No adverse reactions were observed. Tc99m-Dextran provided good definition of lymph channels and sentinel node localization, without the risks related to the use of potentially hazardous labeled materials of biological origin.

  5. Sentinel Asia step 2 utilization for disaster management in Malaysia

    International Nuclear Information System (INIS)

    Moslin, S I; Wahap, N A; Han, O W

    2014-01-01

    With the installation of Wideband InterNetworking engineering test and Demonstration Satellite (WINDS) communication system in the National Space Centre, Banting; officially Malaysia is one of the twelve Sentinel Asia Step2 System Regional Servers in the Asia Pacific region. The system will be dedicated to receive and deliver images of disaster struck areas observed by Asia Pacific earth observation satellites by request of the Sentinel Asia members via WINDS satellite or 'Kizuna'. Sentinel Asia is an initiative of collaboration between space agencies and disaster management agencies, applying remote sensing and web-GIS technologies to assist disaster management in Asia Pacific. When a disaster occurred, participating members will make an Emergency Observation Request (EOR) to the Asian Disaster Reduction Centre (ADRC). Subsequently, the Data Provider Node (DPN) will execute the emergency observation using the participating earth observation satellites. The requested images then will be processed and analysed and later it will be uploaded on the Sentinel Asia website to be utilised for disaster management and mitigation by the requestor and any other international agencies related to the disaster. Although the occurrences of large scale natural disasters are statistically seldom in Malaysia, but we can never be sure with the unpredictable earth climate nowadays. This paper will demonstrate the advantage of using Sentinel Asia Step2 for local disaster management. Case study will be from the recent local disaster occurrences. In addition, this paper also will recommend a local disaster management support system by using the Sentinel Asia Step2 facilities in ANGKASA

  6. Validation of sentinel data.

    NARCIS (Netherlands)

    Bartelds, A.I.M.

    1993-01-01

    The Dutch Sentinel Practice Network, "de Peilstations" started in 1970. The purpose of this network is to gain a better insight into the epidemiology of a number of illnesses and conditions as they are presented to the general practitioner. The network is sponsored by the Ministry of Welfare, Public

  7. Completion Dissection or Observation for Sentinel-Node Metastasis in Melanoma

    NARCIS (Netherlands)

    Faries, M. B.; Thompson, J. F.; Cochran, A. J.; Andtbacka, R. H.; Mozzillo, N; Zager, Jonathan S.; Jahkola, T.; Bowles, T. L.; Testori, Alessandro; Beitsch, P. D.; Hoekstra, H. J.; Moncrieff, M.; Ingvar, C.; Wouters, M. W. J. M.; Sabel, M. S.; Levine, E. A.; Agnese, D.; Henderson, M.; Dummer, R; Rossi, C. R.; Neves, R. I.; Trocha, S. D.; Wright, Sara F.; Byrd, D. R.; Matter, M.; Hsueh, E.; MacKenzie-Ross, A.; Johnson, B. D.; Terheyden, P.; Berger, A. C.; Huston, T. L.; Wayne, J. D.; Smithers, B. Mark; Neuman, H. B.; Schneebaum, S.; Gershenwald, Jeffrey E.; Ariyan, C. E.; Desai, D. C.; Jacobs, L.; McMasters, K. M.; Gesierich, A.; Hersey, P.; Bines, S. D.; Kane, Michael J.; Barth, R. J.; McKinnon, J. G.; Farma, J. M.; Schultz, B. E.; Vidal-Sicart, S.; Hoefer, R. A.; Lewis, David J. M.; Scheri, R.; Kelley, M. C.; Nieweg, O. E.; Noyes, R. D.; Hoon, D. S. B.; Wang, H. -J.; Elashoff, D. A.; Elashoff, R. M.

    2017-01-01

    BACKGROUND Sentinel-lymph-node biopsy is associated with increased melanoma-specific survival (i.e., survival until death from melanoma) among patients with node-positive intermediate-thickness melanomas (1.2 to 3.5 mm). The value of completion lymph-node dissection for patients with sentinel-node

  8. Lymphatic drainage and sentinel node location in breast cancer

    International Nuclear Information System (INIS)

    Uren, R.F.; Howman-Giles, R.B.; Roberts, J.; Renwick, S.; Gillett, D.; Neische, F.; Ramsay-Stewart, G.

    1999-01-01

    Full text: Mammary lymphoscintigraphy using small volume (0.1-0.2 ml) peritumoral injections of 99 Tc m -antimony sulphide colloid provided a map of the lymph drainage of a breast cancer to its draining sentinel lymph nodes in 92 of 102 patients (over 90%). Non-migration of tracer is reduced by post-injection massage for 5 min but may occur especially if the lymphatics are blocked by metastases. Drainage included the axilla in 92%, internal mammary nodes in 43%, supraclavicular nodes in 12% and intramammary interval nodes in 10% of patients. One patient drained to an interpectoral node. Drainage across the centre-line of the breast occurred in 46% of patients but direct drainage to the contralateral side of the patient was not seen. Lymphatic drainage occurred to 1 node field in 52 patients, 2 node fields in 34 patients and 3 node fields in 6 patients, so that 43% of patients had multiple draining node fields. Drainage to non-axillary sites occurred in 51% of patients. In conclusion, mammary lymphoscintigraphy accurately maps sentinel node location in breast cancer. Approximately half of the patients will have sentinel nodes outside the axilla. To achieve complete lymph node staging in patients with breast cancer, it is logical to biopsy these non-axillary sentinel nodes as well as the sentinel nodes in the axilla. Failure to do so will potentially understage the node status in 50% of patients

  9. Sentinel lymph node biopsy from the vantage point of an oncologic surgeon.

    Science.gov (United States)

    Wilson, Lori L

    2009-01-01

    Sentinel lymph node biopsy has greatly influenced the surgical management of clinically localized primary melanoma. Lymphatic mapping and sentinel lymph node biopsy have been used for the selective management of the draining regional lymph node basin of primary cutaneous melanoma. Oncologic surgeons have adopted this procedure to selectively identify occult nodal status in melanoma patients who are at a higher risk of regional metastasis. The current standard of treatment of tumor-positive sentinel lymph node metastasis is immediate completion lymphadenectomy, but considerable debate surrounds the utility of this procedure. This contribution reviews development, technical aspects, selective management of the lymph node basin, and sentinel lymph node biopsy techniques.

  10. Marine mammals as sentinel species for oceans and human health.

    Science.gov (United States)

    Bossart, G D

    2011-05-01

    The long-term consequences of climate change and potential environmental degradation are likely to include aspects of disease emergence in marine plants and animals. In turn, these emerging diseases may have epizootic potential, zoonotic implications, and a complex pathogenesis involving other cofactors such as anthropogenic contaminant burden, genetics, and immunologic dysfunction. The concept of marine sentinel organisms provides one approach to evaluating aquatic ecosystem health. Such sentinels are barometers for current or potential negative impacts on individual- and population-level animal health. In turn, using marine sentinels permits better characterization and management of impacts that ultimately affect animal and human health associated with the oceans. Marine mammals are prime sentinel species because many species have long life spans, are long-term coastal residents, feed at a high trophic level, and have unique fat stores that can serve as depots for anthropogenic toxins. Marine mammals may be exposed to environmental stressors such as chemical pollutants, harmful algal biotoxins, and emerging or resurging pathogens. Since many marine mammal species share the coastal environment with humans and consume the same food, they also may serve as effective sentinels for public health problems. Finally, marine mammals are charismatic megafauna that typically stimulate an exaggerated human behavioral response and are thus more likely to be observed.

  11. Sentinel lymph node and its applications in cancer. Review of literature

    International Nuclear Information System (INIS)

    Leon A, L.; Vigil R, C.; Velarde G, R.; Abugattas S, J.; Leon R, M.; Caceres G, E.; Cano P, R.; Morales G, R.; Aguilar R, C.

    2001-01-01

    In the human body, the lymph nodes groups like in the groin, axilla, neck and others regions, receive the lymphatic drainage from a determined corporal territory, and the first node to receive it is called the sentinel node and as the name suggest, it is the most likely node to contain metastases if present; in the axilla the sentinel node is usually localized in level I. The presence of regional lymph node involvement remains the most reliable prognostic factor and provides accurate nodal staging for woman with epithelial cancers. The most commonly use indicator of prognosis for patients with operable carcinoma of the breast is the histological presence or absence of axillary lymph node metastases. The sentinel node biopsy is a new procedure composed of two steps: the first is the lymphatic mapping where the sentinel node can be identified in the preoperative period by lymphoscintigraphy, and in the operating room by injection of a vital blue dye, and with technetium labeled sulfur colloid injected into the same area as the vital blue dye or in place of the blue dye. In the second step the extracted and a rigorous assessment of the accuracy by pathological examination. Multiple studies have showed that if the sentinel lymph node is negative for metastatic disease, the remaining lymph nodes are also likely to be negative. The value of the sentinel lymph node biopsy is based in the pathologic diagnosis, when it is negative it is possible to avoid axillary dissection. The technique of identification of sentinel lymph node is applied to different types of cancers and distinct localizations, in the penis, malignant melanoma, breast, head and neck (oral cavity, epidermoid carcinoma, malignant melanoma), vulva, gastric, colorectal, 'non small cell lung cancer' and for merkel cell carcinoma. This publication regarding the sentinel lymph node technique and its applications in cancer, represents the routine followed in the Department of Breast Bone and Mixed Tumours of the

  12. The Copernicus Sentinel 4 mission: a geostationary imaging UVN spectrometer for air quality monitoring

    Science.gov (United States)

    Bazalgette Courrèges-Lacoste, G.; Sallusti, M.; Bulsa, G.; Bagnasco, G.; Veihelmann, Ben; Riedl, S.; Smith, D. J.; Maurer, R.

    2017-09-01

    Sentinel-4 is an imaging UVN (UV-VIS-NIR) spectrometer, developed by Airbus Defence and Space under ESA contract in the frame of the joint EU/ESA COPERNICUS program. The mission objective is the operational monitoring of trace gas concentrations for atmospheric chemistry and climate applications - hence the motto of Sentinel-4 "Knowing what we breathe". Sentinel-4 will provide accurate measurements of key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, methane, and aerosol properties over Europe and adjacent regions from a geostationary orbit (see Fig. 1). In the family of already flown UVN spectrometers (SCIAMACHY, OMI, GOME and GOME 2) and of those spectrometers currently under development (Sentinel-5p and Sentinel-5), Sentinel-4 is unique in being the first geostationary UVN mission. Furthermore, thanks to its 60-minutes repeat cycle measurements and high spatial resolution (8x8 km2), Sentinel-4 will increase the frequency of cloud-free observations, which is necessary to assess troposphere variability. Two identical Sentinel-4 instruments (PFM and FM-2) will be embarked, as Customer Furnished Item (CFI), fully verified, qualified and calibrated respectively onto two EUMETSAT satellites: Meteosat Third Generation-Sounder 1 and 2 (MTG-S1 and MTG-S2), whose Flight Acceptance Reviews are presently planned respectively in Q4 2021 and Q1 2030. This paper gives an overview of the Sentinel-4 system1 architecture, its design and development status, current performances and the key technological challenges.

  13. Sentinel node biopsy before neoadjuvant chemotherapy spares breast cancer patients axillary lymph node dissection.

    Science.gov (United States)

    van Rijk, Maartje C; Nieweg, Omgo E; Rutgers, Emiel J T; Oldenburg, Hester S A; Olmos, Renato Valdés; Hoefnagel, Cornelis A; Kroon, Bin B R

    2006-04-01

    Neoadjuvant chemotherapy in breast cancer patients is a valuable method to determine the efficacy of chemotherapy and potentially downsize the primary tumor, which facilitates breast-conserving therapy. In 18 studies published about sentinel node biopsy after neoadjuvant chemotherapy, the sentinel node was identified in on average 89%, and the false-negative rate was on average 10%. Because of these mediocre results, no author dares to omit axillary clearance just yet. In our institute, sentinel lymph node biopsy is performed before neoadjuvant chemotherapy. The aim of this study was to evaluate our experience with this approach. Sentinel node biopsy was performed before neoadjuvant chemotherapy in 25 T2N0 patients by using lymphoscintigraphy, a gamma ray detection probe, and patent blue dye. Axillary lymph node dissection was performed after chemotherapy if the sentinel node contained metastases. Ten patients had a tumor-positive axillary sentinel node, and one patient had an involved lateral intramammary node. Four patients had additional involved nodes in the completion lymph node dissection specimen. The other 14 patients (56%) had a tumor-negative sentinel node and did not undergo axillary lymph node dissection. No recurrences have been observed after a median follow-up of 18 months. Fourteen (56%) of the 25 patients were spared axillary lymph node dissection when the sentinel node was found to be disease free. Performing sentinel node biopsy before neoadjuvant chemotherapy seems successful and reliable in patients with T2N0 breast cancer.

  14. Solar Sentinels: Report of the Science and Technology Definition Team

    Science.gov (United States)

    2006-01-01

    The goal of NASA s Living With a Star (LWS) program is to develop the scientific understanding necessary to effectively address those aspects of the connected Sun Earth system that directly affect life and society. Along with the other elements of LWS, Solar Sentinels aims to discover, understand, and model the heliospheric initiation, propagation, and solar connection of those energetic phenomena that adversely affect space exploration and life and society here on Earth. The Solar Sentinels mission will address the following questions: (1) How, where, and under what circumstances are solar energetic particles (SEPs) accelerated to high energies and how do they propagate through the heliosphere? And (2) How are solar wind structures associated with these SEPs, like CMEs, shocks, and high-speed streams, initiated, propagate, evolve, and interact in the inner heliosphere? The Sentinels STDT recommends implementing this mission in two portions, one optimized for inner heliospheric in-situ measurements and the other for solar remote observations. Sentinels will greatly enhance the overall LWS science return.

  15. SPICE: Sentinel-3 Performance Improvement for Ice Sheets

    Science.gov (United States)

    McMillan, M.; Escola, R.; Roca, M.; Thibaut, P.; Aublanc, J.; Shepherd, A.; Remy, F.; Benveniste, J.; Ambrózio, A.; Restano, M.

    2017-12-01

    For the past 25 years, polar-orbiting satellite radar altimeters have provided a valuable record of ice sheet elevation change and mass balance. One of the principle challenges associated with radar altimetry comes from the relatively large ground footprint of conventional pulse-limited radars, which reduces their capacity to make measurements in areas of complex topographic terrain. In recent years, progress has been made towards improving ground resolution, through the implementation of Synthetic Aperture Radar (SAR), or Delay-Doppler, techniques. In 2010, the launch of CryoSat-2 heralded the start of a new era of SAR Interferometric (SARIn) altimetry. However, because the satellite operated in SARIn and LRM mode over the ice sheets, many of the non-interferometric SAR altimeter processing techniques have been optimized for water and sea ice surfaces only. The launch of Sentinel-3, which provides full non-interferometric SAR coverage of the ice sheets, therefore presents the opportunity to further develop these SAR processing methodologies over ice sheets. Here we present results from SPICE, a 2 year study that focuses on (1) developing and evaluating Sentinel-3 SAR altimetry processing methodologies over the Polar ice sheets, and (2) investigating radar wave penetration through comparisons of Ku- and Ka-band satellite measurements. The project, which is funded by ESA's SEOM (Scientific Exploitation of Operational Missions) programme, has worked in advance of the operational phase of Sentinel-3, to emulate Sentinel-3 SAR and pseudo-LRM data from dedicated CryoSat-2 SAR acquisitions made at the Lake Vostok, Dome C and Spirit sites in East Antarctica, and from reprocessed SARIn data in Greenland. In Phase 1 of the project we have evaluated existing processing methodologies, and in Phase 2 we are investigating new evolutions to the Delay-Doppler Processing (DDP) and retracking chains. In this presentation we (1) evaluate the existing Sentinel-3 processing chain by

  16. Identification of the sentinel lymph node using hemosiderin in locally advanced breast cancer

    Directory of Open Access Journals (Sweden)

    PAULO HENRIQUE WALTER DE AGUIAR

    Full Text Available ABSTRACT Objective: to verify the agreement rate in the identification of sentinel lymph node using an autologous marker rich in hemosiderin and 99 Technetium (Tc99 in patients with locally advanced breast cancer. Methods: clinical trial phase 1, prospective, non-randomized, of 18 patients with breast cancer and clinically negative axilla stages T2=4cm, T3 and T4. Patients were submitted to sub-areolar injection of hemosiderin 48 hours prior to sentinel biopsy surgery, and the identification rate was compared at intraoperative period to the gold standard marker Tc99. Agreement between methods was determined by Kappa index. Results: identification rate of sentinel lymph node was 88.9%, with a medium of two sentinel lymph nodes per patients. The study identified sentinel lymph nodes stained by hemosiderin in 83.3% patients (n=15, and, compared to Tc99 identification, the agreement rate was 94.4%. Conclusion: autologous marker rich in hemosiderin was effective to identify sentinel lymph nodes in locally advanced breast cancer patients.

  17. Examples of Sentinel-2A Mission Exploitation Results

    Science.gov (United States)

    Koetz, Benjamin; Hoersch, Bianca; Gascon, Ferran; Desnos, Yves-Louis; Seifert, Frank Martin; Paganini, Marc; Ramoino, Fabrizio; Arino, Olivier

    2017-04-01

    The Sentinel-2 Copernicus mission will bring significant breakthrough in the exploitation of space borne optical data. Sentinel-2 time series will transform land cover, agriculture, forestry, in-land water and costal EO applications from mapping to monitoring, from snapshot to time series data analysis, from image-based to pixel-based processing. The 5-days temporal revisiting of the Sentinel-2 satellites, when both units will be operated together, will usher us in a new era for time series analysis at high spatial resolutions (HR) of 10-20 meters. The monitoring of seasonal variations and processes in phenology and hydrology are examples of the many R&D areas to be studied. The mission's large swath and systematic acquisitions will further support unprecedented coverage at the national scale addressing information requirements of national to regional policies. Within ESA programs, such as the Data User Element (DUE), Scientific Exploitation of Operational Missions (SEOM) and Climate Change Initiative (CCI), several R&D activities are preparing the exploitation of the Sentinel-2 mission towards reliable measurements and monitoring of e.g. Essential Climate Variables and indicators for the Sustainable Development Goals. Early Sentinel-2 results will be presented related to a range of applications and scientific domains such as agricultural monitoring at national scale (DUE Sen2Agri), wetland extent and condition over African Ramsar sites (DUE GlobWetland-Africa), land cover mapping for climate change (CCI Land Cover), national land monitoring (Cadaster-Env), forest degradation (DUE ForMoSa), urban mapping (DUE EO4Urban), in-land water quality (DUE SPONGE), map of Mediterranean aquaculture (DUE SMART) and coral reef habitat mapping (SEOM S2-4Sci Coral). The above-mentioned activities are only a few examples from the very active international land imaging community building on the long-term Landsat and Spot heritage and knowledge.

  18. Methodology of sentinel node detection

    International Nuclear Information System (INIS)

    Maublant, J.

    2000-01-01

    The isotopic localisation of the sentinel node, i.e., the first functional lymph node in a tumor basin, is probably the fastest growing field ever experienced in nuclear medicine. Although based on the simple concept of the lymphatic migration of Tc-labeled colloids, the choice of the optimal technique remains controversial. We review and discuss the role of the colloids, of the site of injection, of the injected volume, of early imaging and of the colorimetric approach. Initially applied to melanoma and breast cancer, the sentinel node detection is now tested in other types of cancer such as lung, colon and prostate. It could become one of the leading tools in minimally invasive surgical oncology. The nuclear medicine physician has to remain aware of the rapid evolutions in this field in order to be able to answer to a rapidly growing demand. (author)

  19. A Neural Network Approach for GMA Butt Joint Welding

    DEFF Research Database (Denmark)

    Christensen, Kim Hardam; Sørensen, Torben

    2003-01-01

    This paper describes the application of the neural network technology for gas metal arc welding (GMAW) control. A system has been developed for modeling and online adjustment of welding parameters, appropriate to guarantee a certain degree of quality in the field of butt joint welding with full...... penetration, when the gap width is varying during the welding process. The process modeling to facilitate the mapping from joint geometry and reference weld quality to significant welding parameters has been based on a multi-layer feed-forward network. The Levenberg-Marquardt algorithm for non-linear least...

  20. A Neural Network Approach for GMA Butt Joint Welding

    DEFF Research Database (Denmark)

    Christensen, Kim Hardam; Sørensen, Torben

    2003-01-01

    penetration, when the gap width is varying during the welding process. The process modeling to facilitate the mapping from joint geometry and reference weld quality to significant welding parameters has been based on a multi-layer feed-forward network. The Levenberg-Marquardt algorithm for non-linear least......This paper describes the application of the neural network technology for gas metal arc welding (GMAW) control. A system has been developed for modeling and online adjustment of welding parameters, appropriate to guarantee a certain degree of quality in the field of butt joint welding with full...

  1. Sentinel-5 instrument: status of design, performance, and development

    Science.gov (United States)

    Gühne, T.; Keim, C.; Bartsch, P.; Weiß, S.; Melf, M.; Seefelder, W.

    2017-09-01

    The Sentinel-5 instrument is currently under development by a consortium led by Airbus Defence and Space in the frame of the European Union Copernicus program. It is a customer furnished item to the MetOp Second Generation satellite platform, which will provide operational meteorological data for the coming decades. Mission objective of the Sentinel-5 is to monitor the composition of the Earth atmosphere for Copernicus Atmosphere Services by taking measurements of trace gases and aerosols impacting air quality and climate with high resolution and daily global coverage. Therefore the Sentinel-5 provides five dispersive spectrometers covering the UV-VIS (270…500 nm), NIR (685 …773 nm) and SWIR (1590…1675 and 2305…2385 nm) spectral bands with resolutions <=1nm. Spatially the Sentinel-5 provides a 108° field of view with a ground sampling of 7.5 x 7 km2 at Nadir. The development program is post PDR and the build-up of the industrial team is finalised. We report on the instrument architecture and design derived from the driving requirements, the predicted instrument performance, and the general status of the program.

  2. Investigation and control of factors influencing resistance upset butt welding.

    OpenAIRE

    Kerstens, N.F.H.

    2010-01-01

    The purpose of this work is to investigate the factors influencing the resistance upset butt welding process to obtain an understanding of the metal behaviour and welding process characteristics, so that new automotive steels can be welded with reduced development time and fewer failures in production. In principle the welding process is rather simple, the materials to be joined are clamped between two electrodes and pressed together. Because there is an interface present with a higher resist...

  3. Summary of investigations of uranium deposits in the Pumpkin Buttes area, Johnson and Campbell Counties, Wyoming

    Science.gov (United States)

    Troyer, Max L.; McKay, Edward J.; Soister, Paul E.; Wallace, Stewart R.

    1954-01-01

    Uranium minerals were discovered in the Pumpkin Buttes area, Campbell and Johnson Counties, Wyo., by the U. S. Geological Survey in October 1951. From June to November 1952, an area of about 750 square miles was examined for uranium deposits, and 211 localities having abnormally high radioactivity were found; uranium minerals are visible at 121 of these localities. All known uranium mineralization in the area is restricted to sandstones of the Wasatch formation, except sparsely disseminated uranium in the sandstone of the White River formation, which caps the Pumpkin Buttes, mid several localities on the Great Pine Ridge southwest of the Pumpkin Buttes where iron-saturated sandstone and clinker in the Fort Union formation have above-normal radioactivity. The uranium occurrences in the Wasatch formation are in a red sandstone zone 450 to 900 feet above the base of the formation and are of two types: small concretionary masses of uranium, iron, manganese and vanadium minerals in sandstone, and irregular zones in which uranium minerals are disseminated in sandstone. The second type is usually larger but of lower grade than the first. Most of the localities at which uranium occurs are in a north-trending belt about 60 miles long and 18 miles in maximum width.

  4. Characterizing butt-rot fungi on USA-affiliated islands in the western Pacific

    Science.gov (United States)

    Phil Cannon; Ned B. Klopfenstein; Robert L. Schlub; Mee-Sook Kim; Yuko Ota; Norio Sahashi; Roland J. Quitugua; John W. Hanna; Amy L. Ross-Davis; J. D. Sweeney

    2014-01-01

    Ganoderma and Phellinus are genera that commonly cause tree butt-rot on USA-affiliated islands of the western Pacific. These fungal genera can be quite prevalent, especially in older mangrove stands. Although the majority of infections caused by these fungi lead to severe rotting of the heartwood, they typically do not directly kill the living tissues of the sapwood,...

  5. A Study on the compensation margin on butt welding joint of Large Steel plates during Shipbuilding construction

    International Nuclear Information System (INIS)

    Kim, J; Jeong, K; Chung, H; Jeong, H; Ji, M; Yun, C; Lee, J

    2015-01-01

    This paper examines the characteristics of butt welding joint shrinkage for shipbuilding and marine structures main plate. The shrinkage strain of butt welding joint which is caused by the process of heat input and cooling, results in the difference between dimensions of the actual parent metal and the dimensions of design. This, in turn, leads to poor quality in the production of ship blocks and reworking through period of correction brings about impediment on improvement of productivity. Through experiments on butt welding joint's shrinkage strain on large structures main plate, the deformation of welding residual stress in the form of I, Y, V was obtained. In addition, the results of experiments indicate that there is limited range of shrinkage in the range of 1 ∼ 2 mm in 11t ∼ 21.5t thickness and the effect of heat transfer of weld appears to be limited within 1000 mm based on one side of seam line so there was limited impact of weight of parent metal on the shrinkage. Finally, it has been learned that Shrinkage margin needs to be applied differently based on groove phenomenon in the design phase in order to minimize shrinkage. (paper)

  6. BioSentinel: Developing a Space Radiation Biosensor

    Science.gov (United States)

    Santa Maria, Sergio R.

    2015-01-01

    BioSentinel is an autonomous fully self-contained science mission that will conduct the first study of the biological response to space radiation outside low Earth orbit (LEO) in over 40 years. The 4-unit (4U) BioSentinel biosensor system, is housed within a 6-Unit (6U) spacecraft, and uses yeast cells in multiple independent microfluidic cards to detect and measure DNA damage that occurs in response to ambient space radiation. Cell growth and metabolic activity will be measured using a 3-color LED detection system and a metabolic indicator dye with a dedicated thermal control system per fluidic card.

  7. Metal loading in Soda Butte Creek upstream of Yellowstone National Park, Montana and Wyoming; a retrospective analysis of previous research; and quantification of metal loading, August 1999

    Science.gov (United States)

    Boughton, G.K.

    2001-01-01

    Acid drainage from historic mining activities has affected the water quality and aquatic biota of Soda Butte Creek upstream of Yellowstone National Park. Numerous investigations focusing on metals contamination have been conducted in the Soda Butte Creek basin, but interpretations of how metals contamination is currently impacting Soda Butte Creek differ greatly. A retrospective analysis of previous research on metal loading in Soda Butte Creek was completed to provide summaries of studies pertinent to metal loading in Soda Butte Creek and to identify data gaps warranting further investigation. Identification and quantification of the sources of metal loading to Soda Butte Creek was recognized as a significant data gap. The McLaren Mine tailings impoundment and mill site has long been identified as a source of metals but its contribution relative to the total metal load entering Yellowstone National Park was unknown. A tracer-injection and synoptic-sampling study was designed to determine metal loads upstream of Yellowstone National Park.A tracer-injection and synoptic-sampling study was conducted on an 8,511-meter reach of Soda Butte Creek from upstream of the McLaren Mine tailings impoundment and mill site downstream to the Yellowstone National Park boundary in August 1999. Synoptic-sampling sites were selected to divide the creek into discrete segments. A lithium bromide tracer was injected continuously into Soda Butte Creek for 24.5 hours. Downstream dilution of the tracer and current-meter measurements were used to calculate the stream discharge. Stream discharge values, combined with constituent concentrations obtained by synoptic sampling, were used to quantify constituent loading in each segment of Soda Butte Creek.Loads were calculated for dissolved calcium, silica, and sulfate, as well as for dissolved and total-recoverable iron, aluminum, and manganese. Loads were not calculated for cadmium, copper, lead, and zinc because these elements were infrequently

  8. Intraoperative Sentinel Lymph Node Evaluation

    DEFF Research Database (Denmark)

    Shaw, Richard; Christensen, Anders; Java, Kapil

    2016-01-01

    BACKGROUND: Intraoperative analysis of sentinel lymph nodes would enhance the care of early-stage oral squamous cell carcinoma (OSCC). We determined the frequency and extent of cytokeratin 19 (CK19) expression in OSCC primary tumours and surrounding tissues to explore the feasibility of a "clinic......-ready" intraoperative diagnostic test (one step nucleic acid amplification-OSNA, sysmex). METHODS: Two cohorts were assembled: cohort 1, OSCC with stage and site that closely match cases suitable for sentinel lymph node biopsy (SLNB); cohort 2, HNSCC with sufficient fresh tumour tissue available for the OSNA assay (>50......% of tumours. Discordance between different techniques indicated that OSNA was more sensitive than qRT-PCR or RNA-ISH, which in turn were more sensitive than IHC. OSNA results showed CK19 expression in 80% of primary cases, so if used for diagnosis of lymph node metastasis would lead to a false-negative result...

  9. Immunolymphoscintigraphy for metastatic sentinel nodes: test of a model

    DEFF Research Database (Denmark)

    Chakera, A H; Nielsen, B S; Madsen, J

    2011-01-01

    Aim. To develop a method and obtain proof-of-principle for immunolymphoscintigraphy for identification of metastatic sentinel nodes. Methods. We selected one of four tumour-specific antibodies against human breast cancer and investigated (1), in immune-deficient (nude) mice with xenograft human b...... in healthy rabbits. Results and Conclusion. Our paper suggests the theoretical possibility of a model of dual isotope immuno-lymphoscintigraphy for noninvasive, preoperative, malignant sentinel node imaging....

  10. Preliminary evaluation of intraoperative gamma probe detection of the sentinel node

    Energy Technology Data Exchange (ETDEWEB)

    Sierralta, M P; Jofre, M J [Nuclear Medicine Department, Military Hospital, Santiago (Chile); Iglesis, R; Schwartz, R; Gomez, L; Velez, R [Surgery Department, Military Hospital, Santiago (Chile); Sandoval, R [Pathology Department, Military Hospital, Santiago (Chile)

    2002-09-01

    Introduction: The resurgence of the lymphoscintigraphy with the sentinel node concept and the availability of the intraoperative gamma probe have been proposed to avoid the morbidity of an unnecessary regional node dissection. The aim of the study was to evaluate the intraoperative gamma probe use after lymphoscintigraphy for the localization of the sentinel node. Material and methods: Twenty-nine patients were studied, 18 females (62%), mean age 60 {+-} 19 y.o. (range 24-86 y.o.) at the Military Hospital Nuclear Medicine Department. The reference diagnoses were 66% malignant melanoma, 21 % breast cancer, 10 % head and neck cancer and 3% vulvae cancer. Lymphoscintigraphs were performed with Tc99m-Dextran injected intradermally in four points around the primary lesion or around the biopsy site (for melanoma 500 microCi each one; for breast and head and neck 200 microCi each one). Afterwards, dynamic images were taken, followed by intraoperative gamma probe investigations in order to localize and remove the sentinel node. Additionally, isosulfan blue was injected before the surgery was made. Results: Lymphoscintigraphy was positive to detect sentinel node(s) in 20 patients (69%). During the surgery, 40 sentinel nodes were detected. In 33 cases, the intraoperative gamma probe was performed, of which 88 % were radioactives. In 35 nodes, the isosulfan blue was injected, of which 80 % were dyed. The correlation between both techniques was 75 %. The histology study of 37 samples demonstrated that 86% (n=32) were truly ganglionar nodes. Conclusion: The intraoperative gamma probe after lymphoscintigraphy is a useful technique for the localization of the sentinel node.

  11. Preliminary evaluation of intraoperative gamma probe detection of the sentinel node

    International Nuclear Information System (INIS)

    Sierralta, M.P.; Jofre, M.J.; Iglesis, R.; Schwartz, R.; Gomez, L.; Velez, R.; Sandoval, R.

    2002-01-01

    Introduction: The resurgence of the lymphoscintigraphy with the sentinel node concept and the availability of the intraoperative gamma probe have been proposed to avoid the morbidity of an unnecessary regional node dissection. The aim of the study was to evaluate the intraoperative gamma probe use after lymphoscintigraphy for the localization of the sentinel node. Material and methods: Twenty-nine patients were studied, 18 females (62%), mean age 60 ± 19 y.o. (range 24-86 y.o.) at the Military Hospital Nuclear Medicine Department. The reference diagnoses were 66% malignant melanoma, 21 % breast cancer, 10 % head and neck cancer and 3% vulvae cancer. Lymphoscintigraphs were performed with Tc99m-Dextran injected intradermally in four points around the primary lesion or around the biopsy site (for melanoma 500 microCi each one; for breast and head and neck 200 microCi each one). Afterwards, dynamic images were taken, followed by intraoperative gamma probe investigations in order to localize and remove the sentinel node. Additionally, isosulfan blue was injected before the surgery was made. Results: Lymphoscintigraphy was positive to detect sentinel node(s) in 20 patients (69%). During the surgery, 40 sentinel nodes were detected. In 33 cases, the intraoperative gamma probe was performed, of which 88 % were radioactives. In 35 nodes, the isosulfan blue was injected, of which 80 % were dyed. The correlation between both techniques was 75 %. The histology study of 37 samples demonstrated that 86% (n=32) were truly ganglionar nodes. Conclusion: The intraoperative gamma probe after lymphoscintigraphy is a useful technique for the localization of the sentinel node

  12. 78 FR 21540 - Revisions to the California State Implementation Plan, Butte County Air Quality Management...

    Science.gov (United States)

    2013-04-11

    ... the California State Implementation Plan, Butte County Air Quality Management District and Sacramento Metropolitan Air Quality Management District AGENCY: Environmental Protection Agency (EPA). ACTION: Direct... Quality Management District (BCAQMD) and Sacramento Metropolitan Air Quality Management District (SMAQMD...

  13. RTS effect detection in Sentinel-4 data

    Science.gov (United States)

    Candeias, Henrique; Gnata, Xavier; Harlander, Maximilian; Hermsen, Markus; Hohn, Rüdiger; Riedl, Stefan; Skegg, Michael; Williges, Christian; Reulke, Ralf

    2017-09-01

    The future ESA Earth Observation Sentinel-4/UVN is a high resolution spectrometer intended to fly on board a Meteosat Third Generation Sounder (MTG-S) platform, placed in a geostationary orbit. The main objective of this optical mission is to continuously monitor the air quality over Europe in near-real time. The Sentinel-4/UVN instrument operates in three wavelength bands: Ultraviolet (UV: 305-400 nm), Visible (VIS: 400- 500 nm) and Near-infrared (NIR: 750-775 nm). Two dedicated CCD detector have been developed to be used in the Focal Plane Subsystems (FPS), one for the combined UV and VIS band, the other covering the NIR band. Being a high resolution spectrometer with challenging radiometric accuracy requirements, both on spectral and spatial dimensions, an effect such the Random Telegraph Signal (RTS) can represent a relevant contribution for the complete system accuracy. In this work we analyze the RTS effect on data acquired during the FPS testing campaign with qualification models for the Sentinel-4/UVN detectors. This test campaign has been performed in late 2016. The strategy for the impact assessment of RTS is to measure the effect at room temperature and then to extrapolate the results to the at instrument operational temperature. This way, very-long lasting data acquisitions could be avoided since the RTS frequency is much lower at cryogenic temperatures. A reliable technique for RTS effect detection has been developed in order to characterize the signal levels amplitude and occurrence frequencies (flipping rate). We demonstrate the residual impact of the RTS on the global In-Orbit Sentinel-4/UVN instrument performance and products accuracy.

  14. Sentinel lymphnode in breast cancer: an experience with 53 cases

    International Nuclear Information System (INIS)

    Abreu, Benedita Andrade Leal de; Melo, Nayana Alves de Brito; Abreu, Evandro Leal de; Vieira, Carlos Sabas; Abreu, Everardo Leal de; Universidade Federal do Piaui, Maranhao, PI

    2007-01-01

    The value of sentinel lymphnode biopsy or selective linfadenectomy in assessing axillary status in breast carcinoma is well established in medical literature. This work presents a brief study from our preliminary experience with 53 patients submitted to pre-surgical lymphoscintigraphy and intraoperatory detection of sentinel lymphnode and compares our records with those of current medical literature. (author)

  15. Sentinel lymphnode in breast cancer: an experience with 53 cases

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Benedita Andrade Leal de; Melo, Nayana Alves de Brito; Abreu, Evandro Leal de; Vieira, Carlos Sabas; Abreu, Everardo Leal de [Universidade Estadual do Piaui, Maranhao, PI (Brazil). Centro Bionuclear de Diagnostico; Universidade Federal do Piaui, Maranhao, PI (Brazil). Hospital Sao Marco; E-mail: bionuclear@uol.com.br

    2007-09-15

    The value of sentinel lymphnode biopsy or selective linfadenectomy in assessing axillary status in breast carcinoma is well established in medical literature. This work presents a brief study from our preliminary experience with 53 patients submitted to pre-surgical lymphoscintigraphy and intraoperatory detection of sentinel lymphnode and compares our records with those of current medical literature. (author)

  16. Implications of a positive sentinel node in oral squamous cell carcinoma

    DEFF Research Database (Denmark)

    Gurney, Benjamin A S; Schilling, Clare; Putcha, Venkata

    2012-01-01

    BACKGROUND: The role of sentinel node biopsy in head and neck cancer is currently being explored. Patients with positive sentinel nodes were investigated to establish if additional metastases were present in the neck, their distribution, and their impact on outcome. METHODS: In all, 109 patients ...

  17. Persistent Scatterer Interferometry using Sentinel-1 Data

    Science.gov (United States)

    Monserrat, Oriol; Crosetto, Michele; Devanthery, Nuria; Cuevas-Gonzalez, Maria; Qihuan, Huang; Barra, Anna; Crippa, Bruno

    2016-04-01

    This work will be focused on the deformation measurement and monitoring using SAR imagery from the C-band Sentinel-1, a space mission funded by the European Union and carried out by the European Space Agency (ESA) within the Copernicus Programme. The work will firstly address the data processing and analysis procedure implemented by the authors. This includes both Persistent Scatterer Interferometry (PSI) tools to analyse large stacks of SAR images (say, typically more than 20 images), and Differential SAR Interferometry (DInSAR) tools to analyse short SAR image stacks. The work will discuss the characteristics of the main products derived by using Sentinel-1 DInSAR and PSI: deformation maps, deformation velocity maps, deformation time series, residual topographic error, etc. The analysis will be carried out over different types of land use area, e.g. urban, peri-urban and rural areas. The deformation monitoring based on Sentinel-1 data will be compared with the monitoring based on data from pre-existing missions, e.g. C-band ERS and Envisat, X-band TerraSAR-X and CosmoSkyMed, etc. The comparison will concern different study areas, mainly located in Italy and Spain.

  18. The microstructure of aluminum A5083 butt joint by friction stir welding

    International Nuclear Information System (INIS)

    Jasri, M. A. H. M.; Afendi, M.; Ismail, A.; Ishak, M.

    2015-01-01

    This study presents the microstructure of the aluminum A5083 butt joint surface after it has been joined by friction stir welding (FSW) process. The FSW process is a unique welding method because it will not change the chemical properties of the welded metals. In this study, MILKO 37 milling machine was modified to run FSW process on 4 mm plate of aluminum A5083 butt joint. For the experiment, variables of travel speed and tool rotational speed based on capability of machine were used to run FSW process. The concentrated heat from the tool to the aluminum plate changes the plate form from solid to plastic state. Two aluminum plates is merged to become one plate during plastic state and return to solid when concentrated heat is gradually further away. After that, the surface and cross section of the welded aluminum were investigated with a microscope by 400 x multiplication zoom. The welding defect in the FSW aluminum was identified. Then, the result was compared to the American Welding Society (AWS) FSW standard to decide whether the plate can be accepted or rejected

  19. The microstructure of aluminum A5083 butt joint by friction stir welding

    Energy Technology Data Exchange (ETDEWEB)

    Jasri, M. A. H. M.; Afendi, M. [School of Mechatronic Engineering, Universiti Malaysia Perlis, Pauh, 02600, Arau, Perlis (Malaysia); Ismail, A. [UniKL MIMET, JalanPantaiRemis, 32200, Lumut, Perak (Malaysia); Ishak, M. [Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 02600, Pekan, Pahang (Malaysia)

    2015-05-15

    This study presents the microstructure of the aluminum A5083 butt joint surface after it has been joined by friction stir welding (FSW) process. The FSW process is a unique welding method because it will not change the chemical properties of the welded metals. In this study, MILKO 37 milling machine was modified to run FSW process on 4 mm plate of aluminum A5083 butt joint. For the experiment, variables of travel speed and tool rotational speed based on capability of machine were used to run FSW process. The concentrated heat from the tool to the aluminum plate changes the plate form from solid to plastic state. Two aluminum plates is merged to become one plate during plastic state and return to solid when concentrated heat is gradually further away. After that, the surface and cross section of the welded aluminum were investigated with a microscope by 400 x multiplication zoom. The welding defect in the FSW aluminum was identified. Then, the result was compared to the American Welding Society (AWS) FSW standard to decide whether the plate can be accepted or rejected.

  20. 77 FR 13072 - Salmon-Challis National Forest, Butte, Custer and Lemhi Counties, ID, Supplemental Environmental...

    Science.gov (United States)

    2012-03-05

    ... DEPARTMENT OF AGRICULTURE Forest Service Salmon-Challis National Forest, Butte, Custer and Lemhi Counties, ID, Supplemental Environmental Impact Statement to the 2009 Salmon- Challis National Forest... of intent to prepare a supplemental environmental impact statement. SUMMARY: The Salmon-Challis...

  1. Stress Distribution in the Dissimilar Metal Butt Weld of Nuclear Reactor Piping due to the Simulation Technique for the Repair Welding

    International Nuclear Information System (INIS)

    Lee, Hweeseung; Huh, Namsu; Kim, Jinsu; Lee, Jinho

    2013-01-01

    During welding, the dissimilar metal butt welds of nuclear piping are typically subjected to repair welding in order to eliminate defects that are found during post-weld inspection. It has been found that the repair weld can significantly increase the tensile residual stress in the weldment, and therefore, accurate estimation of the weld residual stress due to repair weld, especially for dissimilar metal welds using Ni-based alloy 82/182 in nuclear components, is of great importance in order to assess susceptibility to primary water stress corrosion cracking. In the present study, the stress distributions of dissimilar metal butt welds in nuclear reactor piping subjected to repair weld were investigated based on detailed nonlinear finite element analyses. Particular emphasis was placed on the variation of the stress distribution in the dissimilar metal butt weld according to the finite element welding analysis sequence for the repair welding process

  2. The Western Environmental Technology Office (WETO) Butte, Montana

    International Nuclear Information System (INIS)

    1994-10-01

    This document has been prepared to highlight the research, development, demonstration, testing and evaluation activities funded through the Western Environmental Technology Office (WETO) in Butte, Montana. Technologies and processes described have the potential to enhance DOE's cleanup and waste management efforts, as well as improve US industry's competitiveness in global environmental markets. This information has been assembled from recently produced Office of Technology Development (OTD) documents which highlight technology development activities within each of the OTD program elements. Projects include: Heavy metals contaminated soil project; In Situ remediation integrated program; Minimum additive waste stabilization program; Resource recovery project; Buried waste integrated demonstration; Mixed waste integrated program; Pollution prevention program; and Mine waste technology program

  3. Sentinel Node in Oral Cancer

    DEFF Research Database (Denmark)

    Tartaglione, Girolamo; Stoeckli, Sandro J; de Bree, Remco

    2016-01-01

    /static scan and/or SPECT/CT. RESULTS: Lymphoscintigraphy identified 723 lymphatic basins. 1398 sentinel lymph nodes (SNs) were biopsied (3.2 SN per patient; range, 1-10). Dynamic scan allowed the differentiation of sentinel nodes from second tier lymph nodes. SPECT/CT allowed more accurate anatomical......PURPOSE: Nuclear imaging plays a crucial role in lymphatic mapping of oral cancer. This evaluation represents a subanalysis of the original multicenter SENT trial data set, involving 434 patients with T1-T2, N0, and M0 oral squamous cell carcinoma. The impact of acquisition techniques, tracer...... localization and estimated SN depth more efficiently. After pathological examination, 9.9% of the SN excised (138 of 1398 SNs) showed metastases. The first neck level (NL) containing SN+ was NL I in 28.6%, NL IIa in 44.8%, NL IIb in 2.8%, NL III in 17.1%, and NL IV in 6.7% of positive patients. Approximately...

  4. Organized nation-wide implementation of sentinel lymph node biopsy in Denmark

    DEFF Research Database (Denmark)

    Friis, E.; Galatius, H.; Garne, J.P.

    2008-01-01

    they could include patients into the study. As a result of this strategy the sentinel lymph node staging was fully implemented in all Danish surgical breast cancer centres within three years and all sentinel node biopsies in the period were recorded in the DBCG data centre. Furthermore, the strategy...

  5. The Sentinel satellites revolutionise environmental observation; Los satelites Sentinel revolucionan la observacion medioambiental

    Energy Technology Data Exchange (ETDEWEB)

    River, A.

    2016-08-01

    Europe has in orbit three Sentinel satellites that are the backbone of the ambitious Copernicus system. Aimed at revolutionising environmental observation from both the scientific and commercial points of view, their objective is to capture massive volumes of data on the Earth with a view to ensuring progress in research into climate change, the oceans and the evolution of ice formations. (Author)

  6. [The validity of the sentinel node concept in gastrointestinal cancers].

    Science.gov (United States)

    Kitagawa, Y; Fujii, H; Mukai, M; Ando, N; Kubota, T; Ikeda, T; Ohgami, M; Watanabe, M; Otani, Y; Ozawa, S; Hasegawa, H; Furukawa, T; Nakahara, T; Kubo, A; Kumai, K; Kitajima, M

    2000-03-01

    Although the sentinel node concept has been validated and clinically applied to breast cancer and malignant melanoma, its clinical significance in other solid tumors has not been thoroughly investigated. With regard to gastrointestinal (GI) cancers in particular, our surgeons have been cautious because of the high frequency of skip metastasis and the complicated lymphatic system in the GI tract. We would like to emphasize that so-called skip metastasis has been defined according to anatomic classification of regional lymph nodes and that the lymphatic drainage route must be patient or lesion specific. To test the validity and feasibility of this concept in GI cancers, we have established a radio-guided intraoperative sentinel node navigation system using preoperative endoscopic submucosal injection of radioactive tracer followed by intra-operative gamma-probing. In 131 patients with GI cancers (esophagus: 22, stomach: 71, colorectum: 38), the detection rate of sentinel nades was 91% and overall diagnostic accuracy of lymph node metastasis by sentinel node status was 97%. Initial results suggest further investigation of this procedure as an accurate staging and a minimally invasive approach to early GI cancers.

  7. ORAM-SENTINEL development at Calvert Cliffs. Final report

    International Nuclear Information System (INIS)

    1998-05-01

    Baltimore Gas and Electric, in cooperation with EPRI, has installed ORAM-SENTINEL trademark software at Calvert Cliffs Nuclear Power Plant. This software incorporates models of the safety and support systems that are used to display the defense-in-depth present in the plant and a quantitative assessment of plant risks during proposed on-line maintenance. During 1997, Baltimore Gas and Electric personnel became familiar with the formal computerized Safety Assessment process associated with on-line and outage maintenance. The report describes the motivation for and the development of ORAM-SENTINEL software. It describes generation of Safety Function Assessment Trees and Plant Transient Assessment Trees and their use in evaluating the level of defense-in-depth of key plant safety functions and plant susceptibility to critical transient events. To show decreasing safety conditions, their results are displayed by color indicators ranging from green through yellow and orange to red. The report describes use of the Calvert Probabilistic Safety Assessment with ORAM-SENTINEL code to calculate an instantaneous core damage frequency and the criteria by which this frequency is translated to a color indicator

  8. Identification of the sentinel lymph node in patients with malignant melanoma: what are the reasons for mistakes?

    International Nuclear Information System (INIS)

    Vidal-Sicart, Sergi; Pons, Francesca; Puig, Susana; Vilalta, Antonio; Palou, J.M.; Castel, Teresa; Ortega, Marisa; Martin, Francisco; Rull, Ramon

    2003-01-01

    Scintigraphic identification of the sentinel lymph node is achievable in nearly all patients with malignant melanoma. However, in a very small number of cases the sentinel node fails to be detected, and sometimes recurrence appears during follow-up in patients who had previously tested negative for metastatic disease. The purpose of this study was to review our experience in order to isolate the reasons for erroneous sentinel lymph node identification. The evaluation involved 435 consecutive malignant melanoma patients with AJCC stages I and II (clinically negative nodes) and Breslow thickness >0.76 mm. Lymphoscintigraphy was performed the day before surgery by intradermal administration of technetium-99m labelled nanocolloid. Dynamic and static images were obtained. The sentinel node was intraoperatively identified with the aid of patent blue dye and a hand-held gamma probe. After removal, routine histopathological examination with haematoxylin-eosin (H-E) and immunohistochemistry with S 100 and HMB45 (IHC) were performed. In those patients who developed regional recurrences during follow-up, sentinel nodes were further evaluated by reverse transcriptase-polymerase chain reaction (RT-PCR). Lymphoscintigraphy visualised at least one sentinel node in 434 out of 435 patients (99.8%). Uptake in in-transit sentinel lymph nodes was observed in 32 patients (7.4%). During surgery, localisation and removal of sentinel nodes was successful in 430/435 patients (98.8%). A total of 790 sentinel lymph nodes were harvested, with a mean of 1.8 per patient. Routine histopathological examination with H-E or IHC revealed metastatic disease in 72 patients (16.8%). During a mean follow-up of 26 months, seven of those patients with a negative sentinel node developed regional lymph node metastases. In five of them RT-PCR was positive for micrometastases within the sentinel node. In conclusion, erroneous sentinel lymph node identification can be due to changes in the surgical team

  9. Sentinel lymph node biopsy in local recurrence of cutaneous melanoma

    International Nuclear Information System (INIS)

    Junqueira, G. Jr.; Bodanese, B.; Boff, M.F.; Espindola, M.B.; Haack, R.L.; Frigeri, C.D.L.

    2004-01-01

    Full text: Locally recurrent disease in patients with melanoma is usually defined as cutaneous or subcutaneous arising within 5 cm of the primary site after complete excision of the primary lesion. It may represent residual disease not excised with the primary tumor or the outgrowth of the satellite lesions, which are common with melanoma. Lymphatic mapping and sentinel lymph node (SLN) biopsy is highly accurate in staging nodal basins at risk of regional metastases in primary melanoma patients and identifies those who may benefit from earlier lymphadenectomy. Our purpose was to evaluate the efficacy of sentinel lymph node mapping and biopsy in local recurrence of cutaneous melanoma when the primary lesion was less than 1.0mm thick. Three patients with local recurrence of cutaneous melanoma underwent sentinel lymph node mapping and biopsy. All patients underwent preoperative lymphoscintigraphy to identify the lymphatic basin and the site of the sentinel node. All patients subsequently underwent intra-operative lymphatic mapping and selective lymph node biopsy with vital blue dye and hand-held gamma probe. Excised SLN were analysed by conventional histological staining (H and E) and immunohistochemical staining. In all patients the lymphatic mapping and sentinel lymph node biopsy was successful. The SLN biopsy was negative in two patients and positive in one who underwent therapeutic lymph node dissection. Our results indicate that the SLN mapping and biopsy is also possible in patients having local recurrence of cutaneous melanoma. Although long-term results are not available, early results are promising. (author)

  10. Age of the middle Palaeolithic site of La Butte d'Arvigny (Moissy-Cramayel, Seine-et-Marne); Datation du site paleolithique moyen de la Butte d'Arvigny (Moissy-Cramayel, Seine-et-Marne)

    Energy Technology Data Exchange (ETDEWEB)

    Laurent, M. [Ecole Nationale Superieure de Chimie, Lab. de Travaux Pratiques de Genie Chimique, 75 - Paris (France); Laurent, M.; Bahain, J.J.; Voinchet, P.; Ricard, J.L. [Lab. de Prehistoire du Museum National d' Histoire Naturelle, Institut de Paleontologie Humaine, UMR 6569 du CNRS, 75 - Paris (France); Rousseau, L. [Amiens Univ., Lab. de Sedimentologie et de Geochimie, 80 (France)

    2000-04-01

    The middle Palaeolithic site of La Butte d'Arvigny, close to Melun, was dated using electron spin resonance (ESR) method on burn flint. Five analysed burnt flints give a mean age of 90 000 years, which ascribes Arvigny to the Mousterian laminar complex of northern France. (authors)

  11. SAR Wave Mode Processing- Improvements Towards Sentinel-1 Mission

    Science.gov (United States)

    Johnsen, Harald; Collard, Fabrice

    2013-03-01

    The Sentinel-1 level-2 (L2) ocean product (OCN) has been designed to deliver geophysical parameters related to the wind, waves and surface velocity to a large panel of end-users. Each L2 OCN product contains up to three geophysical components: the radial velocity (RVL), the ocean surface wind field (OWI) and the ocean swell wave spectra (OSW) components. The Sentinel-1 Level 2 OSW component is the two-dimensional ocean surface wave spectra estimated from a Sentinel-1 Level 1 Single-Look Complex (SLC) SAR image by inversion of the corresponding image cross-spectra. The cross spectra are computed by performing inter-looking in azimuth followed by co- and cross-spectra estimation among the detected individual look images. The image from which a single OSW is computed can be a SLC vignette from the WV mode, or a co-polarized subimage extracted from a SM SLC image. The experiences with ASAR have shown the need to improve the modulation transfer functions (MTF), especially the wind dependency in the RAR MTF. The OSW processing scheme is an upgraded version of the ASAR WM Level 2 processing accounting for these findings. The Sentinel-1 Level 2 OSW processing has been evaluated using ASAR WM and ASAR SM data, and preliminary key results are presented in this paper.

  12. Search for an optimal colloid for sentinel node imaging

    International Nuclear Information System (INIS)

    Imam, S.K.; Killingsworth, M.

    2005-01-01

    This study aims at finding a cost-effective and stable colloid of appropriate size to replace antimony sulfide colloid which is now in routine use in Australia for sentinel lymph node (SLN) imaging. For this reason we evaluated three colloids; namely phytate, hepatate and stannous fluoride (SnF 2 ). As colloids of particle size of 100-200 nm seem to be appropriate for sentinel node imaging, the three radiolabelled colloid preparations were filtered through 0.1 and 0.22 μm filters and then studied on electron microscope. Electron microscopy showed that unlike phytate, the particle size of the hepatate and SnF 2 colloids did not increase beyond the size limit of 200 nm over a period of as long as 26 hours. Instead, they remained well within the size limits chosen. The stability of particle size is required for intra-operative gamma probe lymphatic mapping that sometimes may be performed on the following day. Hepatate and SnF 2 colloids appeared to be more suited for sentinel lymph node imaging, the latter being an inhouse product is more cost-effective. Further studies based on nodal uptake and the behavior of these two radiopharmaceuticals in animals is suggested in order to evaluate their potential for future wide-spread application in human sentinel node imaging. (author)

  13. Indications of sentinel node biopsy in thin melanoma

    Directory of Open Access Journals (Sweden)

    Fernanda Braga Silva

    2010-06-01

    Full Text Available Objective: To assess data on survival, recurrence and histological factors in positive and negative sentinel lymph nodes in thin melanoma cases. Methods: A systematic review was conducted on observational studies in four databases (Cochrane Library, Medline, Embase and Lilacs. Positive and negative micrometastases in sentinel lymph node biopsy were compared regarding the clinical outcomes – death and recurrence – and six histological factors – vertical growth phase, Breslow thickness, Clark level, ulceration, regression and mitosis rate. Results: Positive sentinel lymph node is statistically associated with greater risk of death in six studies (OR: 7.2; 95%CI [2.37-21.83]; I2 0% and also to recurrence in three studies (OR: 30.7; 95%CI [12.58-74.92]; I2 36%. Comparing positive and negative groups, the histological factors predicting positive sentinel nodes and poor prognosis were: mitosis rate ≥ 5/mm2 (OR: 16.29; 95%CI [3.64-72.84]; I2 40%; VGP (OR: 2.93; 95%CI [1.08-7.93]; I2 59%; Breslow thickness ≥ 0.75mm (OR: 2.23; 95%CI [1.29-3.86]; I2 0%; and Clark level IV-V (OR: 1.61; 95%CI [1.06-2.44]; I2 34%. Conclusions: The statistically significant results associated with the presence of micrometastases in thin melanomas were Breslow thickness ≥ 0.75 mm, Clark level IV-V and mitoses ≥ 5/mm2, absence of regression. This histological factor of ulceration was associated, but not statistically significant.

  14. Observations of elk movement patterns on Fossil Butte National Monument

    Science.gov (United States)

    Olexa, Edward M.; Soileau, Suzanna Carrithers.; Allen, Leslie A.

    2014-01-01

    The elk herd that frequents Fossil Butte National Monument, a subset of the West Green River elk population, provides visitors with seasonal opportunities to view an iconic species of the western United States. Throughout the year, these elk range across a variety of private, State, and Federal lands within close proximity to the Monument. These lands are managed differently for various uses which can create challenging wildlife-management issues and influence the herd’s seasonal movements and distribution. Research lead by the USGS investigates some of the factors associated with these seasonal changes.

  15. TIG-dressing of High Strength Butt Welded Connection. Part 2 : Physical Testing and Modelling

    NARCIS (Netherlands)

    Van Es, S.H.J.; Kolstein, M.H.; Pijpers, R.J.M.; Bijlaard, F.S.K.

    2014-01-01

    Weld improvement techniques are aimed at reducing the notch effects of welds and generally focus on two aspects: a change of geometry of the weld toe and a change of the weld residual stresses. In this paper, fatigue tests are discussed, performed on butt welded specimens in steel grades ranging

  16. TIG-dressing of high strength butt welded connection - Part 2: physical testing and modelling

    NARCIS (Netherlands)

    Es, S.H.J. van; Kolstein, M.H.; Pijpers, R.J.M.; Bijlaard, F.S.K.

    2013-01-01

    Weld improvement techniques are aimed at reducing the notch effects of welds and generally focus on two aspects: a change of geometry of the weld toe and a change of the weld residual stresses. In this paper, fatigue tests are discussed, performed on butt welded specimens in steel grades ranging

  17. Sentinel lymph nodes in cancer of the oral cavity

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Krogdahl, Annelise

    2005-01-01

    BACKGROUND: Sentinel lymph node biopsy, step sectioning and immunohistochemistry have changed detection of tumour deposits. Isolated tumour cells (ITC) are detected more frequently than earlier because of a changed level of detection. METHODS: A total of 108 sentinel lymph nodes from 30 patients ...... with macrometastasis, five with micrometastasis and two with ITC. CONCLUSION: The ITC are probably precursors of micrometastasis waiting to grow and should be treated as such. Benign inclusions and dendritic cells did not cause problems, but can mimic ITC....

  18. Predictors of sentinel lymph node metastases in breast cancer-radioactivity and Ki-67.

    Science.gov (United States)

    Thangarajah, Fabinshy; Malter, Wolfram; Hamacher, Stefanie; Schmidt, Matthias; Krämer, Stefan; Mallmann, Peter; Kirn, Verena

    2016-12-01

    Since the introduction of the sentinel node technique for breast cancer in the 1990s patient's morbidity was reduced. Tracer uptake is known to be dependent from lymph node integrity and activity of macrophages. The aim of this study was to assess whether radioactivity of the tracer can predict sentinel lymph node metastases. Furthermore, a potential association with Ki-67 index was examined. Non-invasive prediction of lymph node metastases could lead to a further decrease of morbidity. We retrospectively analyzed patients with primary breast cancer who underwent surgery at the Department of Obstetrics and Gynecology in the University Hospital of Cologne between 2012 and 2013. Injection of radioactive tracer was done a day before surgery in the department of Nuclear Medicine. Clinical data and radioactivity of the sentinel node measured the day before and intraoperatively were abstracted from patient's files. Of 246 patients, 64 patients had at least one, five patients had two and one patient had three positive sentinel lymph nodes. Occurrence of sentinel lymph node metastases was not associated with preoperative tracer activity (p = 0,319), intraoperative tracer activity of first sentinel node (p = 0,086) or with loss of tracer activity until operation (p = 0,909). There was no correlation between preoperative Ki-67 index and occurrence of lymph node metastases (p = 0,403). In our cohort, there was no correlation between radioactivity and sentinel node metastases. Tracer uptake might not only be influenced by lymph node metastases and does not predict metastatic lymph node involvement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Laboratory-supported influenza surveillance in Victorian sentinel general practices.

    Science.gov (United States)

    Kelly, H; Murphy, A; Leong, W; Leydon, J; Tresise, P; Gerrard, M; Chibo, D; Birch, C; Andrews, R; Catton, M

    2000-12-01

    Laboratory-supported influenza surveillance is important as part of pandemic preparedness, for identifying and isolating candidate vaccine strains, for supporting trials of anti-influenza drugs and for refining the influenza surveillance case definition in practice. This study describes the implementation of laboratory-supported influenza surveillance in Victorian sentinel general practices and provides an estimate of the proportion of patients with an influenza-like illness proven to have influenza. During 1998 and 1999, 25 sentinel general practices contributed clinical surveillance data and 16 metropolitan practices participated in laboratory surveillance. Serological, virus-antigen detection, virus culture and multiplex polymerase chain reaction procedures were used to establish the diagnosis of influenza. Two laboratories at major teaching hospitals in Melbourne provided additional data on influenza virus identification. General practice sentinel surveillance and laboratory identification of influenza provided similar data on the pattern of influenza in the community between May and September. The clinical suspicion of influenza was confirmed in 49 to 54 per cent of cases seen in general practice.

  20. The sentinel node concept in breast cancer: A commentary

    International Nuclear Information System (INIS)

    Canizales, A.L. . E-mail A.L.Canizales@qmul.ac.uk; Al-Yasi, A.; Gambhir, S.; Morris, G.; Granowska, M.; Britton, K.E.

    2004-01-01

    As there are multiple lymphatic pathways from the breast to the axilla with multiple possible choices for a cancer cell or a colloid, it appears intuitively unusual that one node is preferentially 'chosen'. The intuitive response would be that there is an equal chance for a breast cancer cell to travel by any lymphatic pathway to any axillary node at level 1. If this were true, then after a colloid injection into the peritumoural lymphatics or the periareolar lymphatic plexus, such a colloid has a similar chance to travel to any level 1 axillary node, be it an involved node or an uninvolved node. We have tried to resolve this conflict between intuition and practice. It was tested by identifying and measuring the activity of the radiolabelled colloid in the nodes removed in an axillary clearance and in the sentinel node or nodes after applying a sentinel node technique similar to that of Veronesi et al. The histology of all the nodes that were counted was analysed so that the colloid activity in each node was able to be correlated with its histology, whether it was involved with cancer or not involved. Measurements were obtained in those patients, in whom there were both involved and uninvolved nodes in the axillae. The colloid counts in cpm/g of each node were compared with the related sentinel node findings either involved with cancer or not involved. These were calculated either as the involved to uninvolved that is a 'positive' to 'negative' ratio. The results were that the activity ratio of all involved axillary nodes to uninvolved axillary nodes was about 4:1. The involved Sentinel nodes had on average over 25 times the uptake of the uninvolved Sentinel nodes. P value was <0.009 for a significant difference between colloid uptake in sentinel nodes with positive histology and those with negative histology. It is a new observation that involved axillary nodes show greater uptake of the colloid than uninvolved nodes in all patients where there are both involved

  1. EANM practice guidelines for lymphoscintigraphy and sentinel lymph node biopsy in melanoma

    DEFF Research Database (Denmark)

    Bluemel, Christina; Herrmann, Ken; Giammarile, Francesco

    2015-01-01

    PURPOSE: Sentinel lymph node biopsy is an essential staging tool in patients with clinically localized melanoma. The harvesting of a sentinel lymph node entails a sequence of procedures with participation of specialists in nuclear medicine, radiology, surgery and pathology. The aim of this docume...

  2. Use of pulsed arc welding for butt joint fabrication

    International Nuclear Information System (INIS)

    Merkulov, B.A.

    1977-01-01

    A technology of pulsed-arc butt welding with periodic wire feed to the welding zone has been developed. The pulsed arc is suitable both for submerged and gas-shielded weldings. The technology proposed has some advantages over the stationary-arc welding. Control of the amplitude-frequency characteristics of the process enables one to affect melting and crystallization conditions of the welding crater, weld shape, relation between melting and deposited metal section areas, etc., as well as to reduce heat contribution to the base metal. The new process is shown to be applicable in power engineering. Automatic submerged welding conditions are given for low-carbon and pearlitic heat-resistant steels

  3. California State Implementation Plan; Butte County Air Quality Management District; New Source Review (NSR) Permitting Program

    Science.gov (United States)

    EPA is proposing to approve a revision to the Butte County Air Quality Management District (BCAQMD) portion of the California SIP concerning the District's New Source Review (NSR) permitting program for new and modified sources of air pollution.

  4. Effect of the weld groove shape and pass number on residual stresses in butt-welded pipes

    International Nuclear Information System (INIS)

    Sattari-Far, I.; Farahani, M.R.

    2009-01-01

    This study used finite element techniques to analyze the thermo-mechanical behaviour and residual stresses in butt-welded pipes. The residual stresses were also measured in some welds by using the Hole-Drilling method. The results of the finite element analysis were compared with experimentally measured data to evaluate the accuracy of the finite element modelling. Based on this study, a finite element modelling procedure with reasonable accuracy was developed. The developed FE modelling was used to study the effects of weld groove shape and weld pass number on welding residual stresses in butt-welded pipes. The hoop and axial residual stresses in pipe joints of 6 and 10 mm thickness of different groove shapes and pass number were studied. It is shown that these two parameters may have significant effects on magnitude and distribution of residual stresses in welded pipes.

  5. A preliminary study on sentinel lymph node biopsy. Feasibility and predictive ability in oral cavity cancer

    International Nuclear Information System (INIS)

    Chikamatsu, Kazuaki; Kamada, Hideo; Ninomiya, Hiroshi; Takahashi, Katsumasa; Sakurai, Tsutomu; Oriuchi, Noboru; Furuya, Nobuhiko

    2004-01-01

    The main factor that affects the prognosis of patients with head and neck cancer (HNC) is regional lymph node metastases. For this reason, the accurate evaluation of neck metastases is required for neck management. This study investigates the sentinel lymph node identification and the accuracy of the histopathology of the sentinel lymph node in patients with HNC. Eleven patients with histologically proven oral squamous cell carcinoma accessible to radiocolloid injection were enrolled in this study. Using both lymphoscintigraphy and a handheld gamma probe, the sentinel lymph node could be identified in all 11 patients. Subsequently, the sentinel lymph nodes and the neck dissection specimen were examined for lymph node involvement due to tumor. The histopathology of sentinel lymph nodes was consistent with the pathological N classification in all 11 patients. Furthermore, the histopathology of sentinel lymph nodes was superior to physical examination, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) scan. The results of this study indicate that sentinel lymph node identification is technically feasible and predicts cervical metastases in patients with oral cavity cancer. This may be a useful diagnostic technique for identifying lymph node disease in staging lymph node dissection. (author)

  6. Radiation Protection Considerations about gamma probe-guided intraoperative sentinel lymph node surgery

    International Nuclear Information System (INIS)

    Rodriguez, C.; Jimenez-Hoyuela Garcia, J. L.; Rebollo Aguirre, J. M.; Custodio, A.

    2002-01-01

    The sentinel node concept is based on the sequential dissemination hypothesis. According to it, there's a lymph node (named sentinel node) which is the first receiving cancer cells metastasizing from a primary tumor. Further, others nodes sequentially located might be affected. Surgical performance for several types of cancer includes the complete removal of the tumor and a complete local lymph node dissection (LND). so removing and analyzing the sentinel node may avoid the complete LND. To locate the sentinel node, it's usual the local administration (intradermal injection) of a radiopharmaceutical Tc-99, sulfur colloid (activity about 1 mCi( several hours prior to surgery, and using an intraoperative gamma probe very sensitive to the gamma radiation. Although the activity is injected by the Nuclear Medicine staff, and be exposed to the gamma radiation. In this study we estimated maximum possible doses that would be received by personnel (surgical staff during surgery and pathologists during lumpectomy of the sentinel node). For the surgical staff, to avoid dose errors due to the very low residual activities and not to interfere with the personnel in the surgery room, we estimated doses by taking into account only the physical decay of Tc99m injected. for the pathologists, we estimated the residual activity in the sentinel node with the gamma probe. The highest effective dose rate found was to the surgeon (o,44 μSv/h, respectively. so a surgeon could perform 407 hours/yr, and a pathologist 1717 hours/yr, dedicated exclusively to sentinel node biopsy, before being classified as professionally exposed to radiation, and 4070 and 17170 hours per year, respectively, to surpass the annual limits (national regulations of the European Communities). In short, radiation doses to clinical staff involved in the technique are low, and in normal conditions, by establishing appropriate procedures (precautions during surgery, during manipulation surgical specimen...) control

  7. Wrought stainless steel butt-welding fittings: including reference to other corrosion resistant materials - approved 1971

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    ANSI B16.9 is the American Standard for steel butt-welding fittings and although not so stated, it is implied that its scope deals primarily with the schedules of wall thicknesses which are common to carbon steel and the grades of alloy steel piping that are selected for pressure and temperature considerations. The purpose of this standard is to provide industry with a set of dimensional standards for butt-welding fittings that can be used with these light wall pipes of corrosion resisting materials. The center-to-end dimensions of all fittings are identical with those in ANSI B16.9 which give to industry the advantage of uniform design room practice and a maximum utilization of existing die equipment. The only departure from this is in the lap-joint stub end where for purposes of economy the face-to-end of the product has been reduced for use with thin wall piping

  8. 77 FR 18266 - Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines; Revised...

    Science.gov (United States)

    2012-03-27

    ... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 731-TA-865-867 (Second Review)] Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines; Revised Schedule for the Subject Reviews AGENCY: United States International Trade Commission. ACTION: Notice. DATES: Effective Date: March...

  9. Factors influencing sentinel lymph node identification failure in breast cancer surgery

    DEFF Research Database (Denmark)

    Straalman, K.; Kristoffersen, U.S.; Galatius, H.

    2008-01-01

    The purpose of this study was to investigate potential risk factors for failed sentinel lymph node identification in breast cancer surgery. Patient characteristics, tumour characteristics, surgeon experience and detection success/failure were registered at 748 sentinel lymph node biopsy procedures...... at our inpatient clinic. Data were analysed with backward stepwise multiple logistic regression with a cut-off point of p

  10. Sentinel lymph node mapping in minimally invasive surgery: Role of imaging with color-segmented fluorescence (CSF).

    Science.gov (United States)

    Lopez Labrousse, Maite I; Frumovitz, Michael; Guadalupe Patrono, M; Ramirez, Pedro T

    2017-09-01

    Sentinel lymph node mapping, alone or in combination with pelvic lymphadenectomy, is considered a standard approach in staging of patients with cervical or endometrial cancer [1-3]. The goal of this video is to demonstrate the use of indocyanine green (ICG) and color-segmented fluorescence when performing lymphatic mapping in patients with gynecologic malignancies. Injection of ICG is performed in two cervical sites using 1mL (0.5mL superficial and deep, respectively) at the 3 and 9 o'clock position. Sentinel lymph nodes are identified intraoperatively using the Pinpoint near-infrared imaging system (Novadaq, Ontario, CA). Color-segmented fluorescence is used to image different levels of ICG uptake demonstrating higher levels of perfusion. A color key on the side of the monitor shows the colors that coordinate with different levels of ICG uptake. Color-segmented fluorescence may help surgeons identify true sentinel nodes from fatty tissue that, although absorbing fluorescent dye, does not contain true nodal tissue. It is not intended to differentiate the primary sentinel node from secondary sentinel nodes. The key ranges from low levels of ICG uptake (gray) to the highest rate of ICG uptake (red). Bilateral sentinel lymph nodes are identified along the external iliac vessels using both standard and color-segmented fluorescence. No evidence of disease was noted after ultra-staging was performed in each of the sentinel nodes. Use of ICG in sentinel lymph node mapping allows for high bilateral detection rates. Color-segmented fluorescence may increase accuracy of sentinel lymph node identification over standard fluorescent imaging. The following are the supplementary data related to this article. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Sentinel Lymph Node Biopsy in Breast Cancer: A Clinical Review and Update.

    Science.gov (United States)

    Zahoor, Sheikh; Haji, Altaf; Battoo, Azhar; Qurieshi, Mariya; Mir, Wahid; Shah, Mudasir

    2017-09-01

    Sentinel lymph node biopsy has become a standard staging tool in the surgical management of breast cancer. The positive impact of sentinel lymph node biopsy on postoperative negative outcomes in breast cancer patients, without compromising the oncological outcomes, is its major advantage. It has evolved over the last few decades and has proven its utility beyond early breast cancer. Its applicability and efficacy in patients with clinically positive axilla who have had a complete clinical response after neoadjuvant chemotherapy is being aggressively evaluated at present. This article discusses how sentinel lymph node biopsy has evolved and is becoming a useful tool in new clinical scenarios of breast cancer management.

  12. The evolution of the sentinel node procedure in the treatment of breast cancer.

    Science.gov (United States)

    Tvedskov, Tove Filtenborg

    2017-10-01

    This thesis is based on 10 original articles, of which 3 were previously included in the PhD thesis "Staging of women with breast cancer after introduction of sentinel node guided axillary dissection". In the PhD thesis is was shown that the introduction of sentinel lymph node dissection (SLND) in the treatment of breast cancer in Denmark has resulted in an increased identification of patients with micrometastases or isolated tumor cells (ITC) in the lymph nodes. Not all these small metastases are likely to disseminate to non-sentinel nodes. This thesis provides evidence that a previous surgical excision of a breast tumor is likely to lead to iatrogenic displacement of tumor cells resulting in a nearly four-fold increased risk of ITC in the sentinel node. These tumor cells are not associated with non-sentinel node metastases. Especially ITC, but also micrometastases and some macrometastases, are not identified on perioperative frozen sections, but found postoperatively at the conventional histopathological examination. These patients are offered an axillary lymph node dissection (ALND) as a second procedure. It has been suggested that this two-stage procedure reduces the number of lymph nodes removed, because of fibroses from previous surgery. In this thesis it was shown that a two-stage procedure does not result in a clinically relevant impairment of the number of lymph nodes removed by ALND. Based on patient, tumor, and sentinel node characteristics from the Danish Breast Cancer Group database, two predictive models for non-sentinel node metastases, when only micrometastases or ITC are found in the sentinel node, were developed, as a part of the PhD thesis. These two models have now been internally validated, and a cross-validation in a Finnish patient material has been performed in cooperation with researchers from Helsinki. The model for patients with micrometastases proved to be robust under internal as well as external validation and could be used to identify

  13. Butt Weldability for SS400 Using Laser-Arc Hybrid Welding

    International Nuclear Information System (INIS)

    Kim, Jong Do; Myoung, Gi Hoon; Park, Duck; Myoung, Gi Hoon; Park, In Duck

    2016-01-01

    This study presents results of an experimental investigation of the laser-arc, hybrid, butt welding process of SS400 structural steel. Welding parameters including laser power, welding current and speed were varied in order to obtain one-pass, full-penetration welds without defects. The conditions that resulted in optimal beads were identified. After welding, hardness measurements and microstructure observations were carried out in order to study weld properties. The mechanical properties of both the base material and welded specimen were compared based on the results of tensile strength measurements. The yield and tensile strengths were found to be similar

  14. Butt Weldability for SS400 Using Laser-Arc Hybrid Welding

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Do; Myoung, Gi Hoon; Park, Duck [Korea Maritime and Ocean Univ., Busan (Korea, Republic of); Myoung, Gi Hoon; Park, In Duck [Korea Institute of Machinery and Materials, Busan (Korea, Republic of)

    2016-07-15

    This study presents results of an experimental investigation of the laser-arc, hybrid, butt welding process of SS400 structural steel. Welding parameters including laser power, welding current and speed were varied in order to obtain one-pass, full-penetration welds without defects. The conditions that resulted in optimal beads were identified. After welding, hardness measurements and microstructure observations were carried out in order to study weld properties. The mechanical properties of both the base material and welded specimen were compared based on the results of tensile strength measurements. The yield and tensile strengths were found to be similar.

  15. [Role of sentinel lymph nodes and lymphatic mapping of colorectal cancer].

    Science.gov (United States)

    Ivanov, K; Kolev, N; Ignatov, V; Temelkov, T; Madzhov, R

    2005-01-01

    The accuracy of staging of colorectal cancer is dependable of number of lymph nodes, colected and investegated from the pathologist. Moreover 50% of newfounded cases with colorectal cancer are diagnosed as I or II stage of the desease. Between 15% and 20% of these patients develop regional or distant metastases around 5 years after the examination, despite of the radical surgery. This may be due to pathological "understaging" (decrease of the stage), becouse of missed micrometastases, which size often is smaller than 5 mm. High accurate and specific pathologoanatomical methods for "ultrastaging" are cost-expensive, therefore their selective application to labeled sentinel lymph nodes has a economical benefit and saves a time. Moreover it is decreasing the understaging effect, assosiated with convectional pathologoanatomical investigaton. In the future, the technical progress will develop the intensive competiton between the sentinel lymph node mapping and the improved imaging diagnostic techniques as flurodeoxyglucose (18FDG), positron emision tomography (PET), or the other molecular imaging techniques. Unfortunately, the limited spatial resolution of these techniques, do not allow to be used for tumor staging as sentinel lymph node techniques. Therefore the sentinel lymphnode mapping become the choice of the lymphnode staging technique.

  16. [Intraoperative detection of the sentinel lymph nodes in lung cancer].

    Science.gov (United States)

    Akopov, A L; Papayan, G V; Chistyakov, I V

    2015-01-01

    An analysis of the scientific data was made. It was used the literature devoted to the intraoperative visualization of the sentinel lymph nodes in patients with lung cancer. Correct detection of such lymph nodes with following pathologic investigation allowed limiting the volume of lympho-dissection in a number of patients. There is the possibility of maximal in-depth study of the sentinel lymph nodes by purposeful application of most sensible pathologic and molecular methods for detection their micrometastatic lesions. At the same time the treatment strategy and prognosis could be determined. The authors present the results of an application of dye techniques, radioactive preparation and fluorescence imaging for sentinel lymph node detection. Advantages and disadvantages of the methods are shown in the article. There are validated the prospects of technical development, study of information value of new applications and the most perspective method of fluorescence indocyanine green visualization by lymph outflow.

  17. [Utility and advantages of single tracer subareolar injection in sentinel lymph node biopsy in breast cancer].

    Science.gov (United States)

    Armas, Fayna; Hernández, María Jesús; Vega, Víctor; Gutiérrez, Isabel; Jiménez, Concepción; Pavcovich, Marta; Báez, Beatriz; Pérez-Correa, Pedro; Núñez, Valentín

    2005-10-01

    Sentinel lymph node (SLN) biopsy is a reliable technique for determining axillary status in patients with early breast cancer. This technique is a minimally invasive procedure that can avoid the use of lymphadenectomy in patients without axillary involvement. We present a validation study of SLN biopsy with subareolar injection of 99mTc-nanocolloids. We studied 100 patients with early breast cancer (T1 and T2) over a 2-year period. All patients underwent deep subareolar-injection of 99mTc-nanocoloid for localization of the sentinel node. Images were obtained and when the sentinel node was seen, it was marked on the skin. All patients underwent tumor excision and radioguided SLN biopsy followed by complete lymphadenectomy. Histopathological analysis of sentinel nodes was performed by hematoxylin-eosin and immunohistochemistry with cytokeratins. The sentinel node was identified in all patients, and a mean of 1.95 sentinel nodes per patient were found. Lymphatic metastases in the sentinel node were found in 44 patients and in 15 of these tumoral spread was also found in the remaining axillary nodes. In the 56 remaining patients the sentinel node was free of metastasis, but in two of them a non-sentinel node was found to be positive (4.5% false negative rate). Sensitivity was 95.7% (44/46), specificity was 100% (54/54), the positive predictive value was 100% and the negative predictive value was 96.4% (54/56). SLN biopsy is an accurate alternative to complete axillary lymph node dissection in patients with early-stage breast cancer. This technique improves the staging of these patients and decreases the morbidity associated with lymphadenectomy. The advantages of subareolar injection are that a single injection site is required, the tumor does not have to be located by other techniques, it allows rapid visualization of the sentinel node and avoids the "shine through phenomenon" when the tumor is located near the axilla.

  18. BUSTED BUTTE TEST FACILITY GROUND SUPPORT CONFIRMATION ANALYSIS

    International Nuclear Information System (INIS)

    Bonabian, S.

    1998-01-01

    The main purpose and objective of this analysis is to confirm the validity of the ground support design for Busted Butte Test Facility (BBTF). The highwall stability and adequacy of highwall and tunnel ground support is addressed in this analysis. The design of the BBTF including the ground support system was performed in a separate document (Reference 5.3). Both in situ and seismic loads are considered in the evaluation of the highwall and the tunnel ground support system. In this analysis only the ground support designed in Reference 5.3 is addressed. The additional ground support installed (still work in progress) by the constructor is not addressed in this analysis. This additional ground support was evaluated by the A/E during a site visit and its findings and recommendations are addressed in this analysis

  19. Ocean Wave Parameters Retrieval from Sentinel-1 SAR Imagery

    Directory of Open Access Journals (Sweden)

    Weizeng Shao

    2016-08-01

    Full Text Available In this paper, a semi-empirical algorithm for significant wave height (Hs and mean wave period (Tmw retrieval from C-band VV-polarization Sentinel-1 synthetic aperture radar (SAR imagery is presented. We develop a semi-empirical function for Hs retrieval, which describes the relation between Hs and cutoff wavelength, radar incidence angle, and wave propagation direction relative to radar look direction. Additionally, Tmw can be also calculated through Hs and cutoff wavelength by using another empirical function. We collected 106 C-band stripmap mode Sentinel-1 SAR images in VV-polarization and wave measurements from in situ buoys. There are a total of 150 matchup points. We used 93 matchups to tune the coefficients of the semi-empirical algorithm and the rest 57 matchups for validation. The comparison shows a 0.69 m root mean square error (RMSE of Hs with a 18.6% of scatter index (SI and 1.98 s RMSE of Tmw with a 24.8% of SI. Results indicate that the algorithm is suitable for wave parameters retrieval from Sentinel-1 SAR data.

  20. California Air Quality State Implementation Plans; Final Approval; Butte County Air Quality Management District; Stationary Source Permits

    Science.gov (United States)

    EPA is taking final action to approve a revision to the Butte County Air Quality Management District (BCAQMD) portion of the California State Implementation Plan (SIP). This revision concerns the District's New Source Review (NSR) permitting program.

  1. Ice Velocity Measurement from SAR: Comparison of Sentinel-1A and RADARSAT-2

    DEFF Research Database (Denmark)

    Kusk, Anders; Dall, Jørgen

    awaits processing. The first Sentinel-1A Greenland-wide observation campaign was carried out in January-March 2015, and ice velocity fields with nearly complete coverage has already been demonstrated [1]. A preliminary IV map using the DTU IPP processor (not all pairs processed) is attached...... with this abstract. The overlapping temporal coverage of the second RADARSAT-2 campaign and the first Sentinel-1 campaign allows a comparison of the two sensors in terms of: Impact of differing imaging modes (stripmap vs TOPS). The better coverage of Sentinel-1 is at the cost of a reduced azimuth resolution, however......, where the backscatter is more homogeneous, offset-tracking relies instead on speckle tracking, reducing the need for high resolution. With more than one revisit, Sentinel-1 can generate 24-day baselines, and this allows a comparison of the two sensor modes without the influence of the temporal baseline...

  2. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    Science.gov (United States)

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  3. Design considerations, architecture, and use of the Mini-Sentinel distributed data system.

    Science.gov (United States)

    Curtis, Lesley H; Weiner, Mark G; Boudreau, Denise M; Cooper, William O; Daniel, Gregory W; Nair, Vinit P; Raebel, Marsha A; Beaulieu, Nicolas U; Rosofsky, Robert; Woodworth, Tiffany S; Brown, Jeffrey S

    2012-01-01

    We describe the design, implementation, and use of a large, multiorganizational distributed database developed to support the Mini-Sentinel Pilot Program of the US Food and Drug Administration (FDA). As envisioned by the US FDA, this implementation will inform and facilitate the development of an active surveillance system for monitoring the safety of medical products (drugs, biologics, and devices) in the USA. A common data model was designed to address the priorities of the Mini-Sentinel Pilot and to leverage the experience and data of participating organizations and data partners. A review of existing common data models informed the process. Each participating organization designed a process to extract, transform, and load its source data, applying the common data model to create the Mini-Sentinel Distributed Database. Transformed data were characterized and evaluated using a series of programs developed centrally and executed locally by participating organizations. A secure communications portal was designed to facilitate queries of the Mini-Sentinel Distributed Database and transfer of confidential data, analytic tools were developed to facilitate rapid response to common questions, and distributed querying software was implemented to facilitate rapid querying of summary data. As of July 2011, information on 99,260,976 health plan members was included in the Mini-Sentinel Distributed Database. The database includes 316,009,067 person-years of observation time, with members contributing, on average, 27.0 months of observation time. All data partners have successfully executed distributed code and returned findings to the Mini-Sentinel Operations Center. This work demonstrates the feasibility of building a large, multiorganizational distributed data system in which organizations retain possession of their data that are used in an active surveillance system. Copyright © 2012 John Wiley & Sons, Ltd.

  4. Preliminary experiences with sentinel lymph node detection in cases of vulvar malignancy

    International Nuclear Information System (INIS)

    Zambo, Katalin; Schmidt, Erzsebet; Dehghani, Babak; Hartmann, Tamas; Bodis, Jozsef; Kornya, Laszlo; Tinneberg, Hans Rudolf

    2002-01-01

    Lymph node status is the most important prognostic factor in vulvar malignancy. The aim of this pilot study was to explore the clinical significance of radionuclide lymphoscintigraphy in the management of vulvar neoplasms. Eight patients with squamous cell carcinoma and two patients with malignant melanoma of the vulva were studied with 100 MBq technetium-99m nanocolloid (Sentiscint, OSSKI, Budapest) 1 day before surgery. The location of the sentinel lymph node was checked by a single-head gamma camera-computer system (MB 9200, Mediso, Budapest). Vulvectomy with bilateral inguinofemoral lymphadenectomy was performed in each case. At lymphadenectomy, the sentinel lymph node was separately removed and histologically studied. Three of the ten patients had positive sentinel lymph nodes (micrometastasis). Five months later one of them had local recurrence of the vulvar cancer, and another had inguinal recurrence of the tumour 6 months postoperatively; the third patient was operated on only recently. Our preliminary results are impressive and suggest that lymphoscintigraphy is an easy and reliable method for detection of the sentinel lymph node in vulvar malignancy. (orig.)

  5. Influence of previous breast surgery in sentinel lymph node biopsy in patients with breast cancer.

    Science.gov (United States)

    López-Prior, V; Díaz-Expósito, R; Casáns Tormo, I

    The aim of this study was to review the feasibility of selective sentinel lymph node biopsy in patients with previous surgery for breast cancer, as well as to examine the factors that may interfere with sentinel node detection. A retrospective review was performed on 91 patients with breast cancer and previous breast surgery, and who underwent sentinel lymph node biopsy. Patients were divided into two groups according to their previous treatment: aesthetic breast surgery in 30 patients (group I) and breast-conserving surgery in 61 (group II). Lymphoscintigraphy was performed after an intra-tumour injection in 21 cases and a peri-areolar injection in 70 cases. An analysis was made of lymphatic drainage patterns and overall sentinel node detection according to clinical, pathological and surgical variables. The overall detection of the sentinel lymph node in the lymphoscintigraphy was 92.3%, with 7.7% of extra-axillary drainages. The identification rate was similar after aesthetic breast surgery (93.3%) and breast-conserving surgery (91.8%). Sentinel lymph nodes were found in the contralateral axilla in two patients (2.2%), and they were included in the histopathology study. The non-identification rate in the lymphoscintigraphy was 7.7%. There was a significantly higher non-detection rate in the highest histological grade tumours (28.6% grade III, 4.5% grade I and 3.6% grade II). Sentinel lymph node biopsy in patients with previous breast surgery is feasible and deserves further studies to assess the influence of different aspects in sentinel node detection in this clinical scenario. A high histological grade was significantly associated with a lower detection. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  6. Sentinel-1A/B Combined Product Geolocation Accuracy

    Directory of Open Access Journals (Sweden)

    Adrian Schubert

    2017-06-01

    Full Text Available Sentinel-1A and -1B are twin spaceborne synthetic aperture radar (SAR sensors developed and operated by the European Space Agency under the auspices of the Copernicus Earth observation programme. Launched in April 2014 and April 2016, Sentinel-1A and -1B are currently operating in tandem, in a common orbital configuration to provide an increased revisit frequency. In-orbit commissioning was completed for each unit within months of their respective launches, and level-1 SAR products generated by the operational SAR processor have been geometrically calibrated. In order to compare and monitor the geometric characteristics of the level-1 products from both units, as well as to investigate potential improvements, products from both satellites have been monitored since their respective commissioning phases. In this study, we present geolocation accuracy estimates for both Sentinel-1 units based on the time series of level-1 products collected thus far. While both units were demonstrated to be performing consistently, and providing SAR data products according to the nominal product specifications, a subtle beam- and mode-dependent azimuth bias common to the data from both units was identified. A method for removing the bias is proposed, and the corresponding improvement to the geometric accuracies is demonstrated and quantified.

  7. Verification of the Sentinel-4 focal plane subsystem

    Science.gov (United States)

    Williges, Christian; Uhlig, Mathias; Hilbert, Stefan; Rossmann, Hannes; Buchwinkler, Kevin; Babben, Steffen; Sebastian, Ilse; Hohn, Rüdiger; Reulke, Ralf

    2017-09-01

    The Sentinel-4 payload is a multi-spectral camera system, designed to monitor atmospheric conditions over Europe from a geostationary orbit. The German Aerospace Center, DLR Berlin, conducted the verification campaign of the Focal Plane Subsystem (FPS) during the second half of 2016. The FPS consists, of two Focal Plane Assemblies (FPAs), two Front End Electronics (FEEs), one Front End Support Electronic (FSE) and one Instrument Control Unit (ICU). The FPAs are designed for two spectral ranges: UV-VIS (305 nm - 500 nm) and NIR (750 nm - 775 nm). In this publication, we will present in detail the set-up of the verification campaign of the Sentinel-4 Qualification Model (QM). This set up will also be used for the upcoming Flight Model (FM) verification, planned for early 2018. The FPAs have to be operated at 215 K +/- 5 K, making it necessary to exploit a thermal vacuum chamber (TVC) for the test accomplishment. The test campaign consists mainly of radiometric tests. This publication focuses on the challenge to remotely illuminate both Sentinel-4 detectors as well as a reference detector homogeneously over a distance of approximately 1 m from outside the TVC. Selected test analyses and results will be presented.

  8. Sentinel lymph node identification in breast cancer using periareolar and subdermal injection of the radiopharmaceutical in four points

    International Nuclear Information System (INIS)

    Coelho-Oliveira, Afranio; Rocha, Augusto Cesar Peixoto; Gutfilen, Bianca; Pessoa, Maria Carolina Pinheiro; Fonseca, Lea Mirian Barbosa da

    2004-01-01

    The aim of this study was to identify the sentinel node by periareolar injection of the radiopharmaceutical in four points, regardless of tumor topography. The sentinel node biopsy reduces morbidity in axillary staging. Fifty-seven sentinel node biopsies were prospectively performed in two groups: group A (25 patients) and group B (32 patients). The peritumoral injection technique was used in group A and the new injection technique in four points was used in group B. The sentinel node biopsies were studied by imprint cytology and hematoxylin and eosin staining followed by axillary lymph node dissection in all patients of group A and only in the positive cases of group B. In group A, 88% (22/25) of the sentinel nodes were identified. There was no false negative case; the sensibility and specificity were of 100%. In group B, 96% (31/32) of sentinel nodes were identified and the status of the axillary lymph nodes showed a predictive positive value of 100%. The number of sentinel nodes varied from 1 to 7, mode of 1 and median of 2.7. The hotspot area was 10 to 100 times the background radiation. The periareolar injection in four points seems to be a good lymphatic mapping method for identification of the sentinel node. We suggest the standardization of this site for injections to identify the sentinel node, although further studies to confirm these findings are necessary. (author)

  9. Age of the middle Palaeolithic site of La Butte d'Arvigny (Moissy-Cramayel, Seine-et-Marne)

    International Nuclear Information System (INIS)

    Laurent, M.; Laurent, M.; Bahain, J.J.; Voinchet, P.; Ricard, J.L.; Rousseau, L.

    2000-01-01

    The middle Palaeolithic site of La Butte d'Arvigny, close to Melun, was dated using electron spin resonance (ESR) method on burn flint. Five analysed burnt flints give a mean age of 90 000 years, which ascribes Arvigny to the Mousterian laminar complex of northern France. (authors)

  10. 76 FR 5205 - Carbon Steel Butt-Weld Pipe Fittings from Brazil, China, Japan, Taiwan, and Thailand

    Science.gov (United States)

    2011-01-28

    ...)] Carbon Steel Butt-Weld Pipe Fittings from Brazil, China, Japan, Taiwan, and Thailand AGENCY: United... Thailand. SUMMARY: The Commission hereby gives notice of the scheduling of expedited reviews pursuant to..., Taiwan, and Thailand would be likely to lead to continuation or recurrence of material injury within a...

  11. 75 FR 60814 - Carbon Steel Butt-Weld Pipe Fittings From Brazil, China, Japan, Taiwan, and Thailand

    Science.gov (United States)

    2010-10-01

    ...)] Carbon Steel Butt-Weld Pipe Fittings From Brazil, China, Japan, Taiwan, and Thailand AGENCY: United... Thailand. SUMMARY: The Commission hereby gives notice that it has instituted reviews pursuant to section... Thailand would be likely to lead to continuation or recurrence of material injury. Pursuant to section 751...

  12. Sentinel lymph node in breast cancer using a radiocolloid particle produced in Argentina

    International Nuclear Information System (INIS)

    Velazquez Espeche, M.H.; Soroa, V.E.; Castiglia, S.G. de

    2004-01-01

    Full text: A number of different approaches have been adopted in the application of technique to detect sentinel lymph node. The main variables are related to size of colloid used, the time to surgery following administration of the colloid, the volume of injection and the site of administration. Optimal detections of sentinel lymph node requires the use of radiopharmaceuticals which clear rapidly from the site of injection and which will be wholly retained at the level of first tier nodes. Our objective was to apply a radiocolloid particle of size between 100-220 nm produced in Argentina by CNEA and to determine its efficacy in sentinel node detections in breast cancer. The particle size was determinate by successive filtrations of a single sample through 450, 220, 100 and 20 nm pore size filters (Whatmaan, UK). The product stability was determined by chromatography controls with ITLC, The pattern of biodistribution in animal was studied in Wistar rats. Twenty female patients with breast cancer diagnosed by clinical, mammography and cytology, were investigated. Four injections of 7.4-22 MBq of 99mTc human albumin radio colloid in volume of 0.5 ml, were injected along the subcutaneous peripheral tumor margins when the tumor was palpable. Peri-subareolar subcutaneous injection in volume of 0.1 ml was also employed as an alternative in few cases. After the injection the patient massaged the injection site for about five minutes. Lymphoscintigrams were acquired in dynamic, static and transmission modes. The sentinel node was marked with a demographic pencil with the patient lying supine and with the arm on the affected side abducted at approximately 90 0 to ensure the same anatomical localization as during the surgery. During the surgery a gamma probe localized the sentinel node by count and sound. Based on the size of particles, the distribution was 90% between 100-220 nm, 7.3% between 200 and 450 nm and 2.7% less than 100 nm. The radiolabel purity was greater than

  13. Sentinel Lymph Node Biopsy (SLNB) for Breast Cancer (BC) - Validation Protocol of the Technique

    International Nuclear Information System (INIS)

    Blidaru, A.; Bordea, C.I.; Condrea, Ileana; Albert, Paul

    2006-01-01

    Full text: The sentinel ganglion concept originates in the assumption according to which the primary tumor drains into a specific ganglionar area and then runs through the lymphatic nodes in an orderly, sequential mode. When neoplastic dissemination along the lymphatic pathway occurs, there is an initial invasion of a specific lymph node (rarely more than one) located on the drainage route. That firstly lymph node has been identified as the sentinel node, which mirrors the regional ganglionar status. In order to establish the indication for lymphadenectomy and avoid the situations in which such a surgical procedure would be of no use (N-), the only correct method consists in the identification and biopsy of the sentinel node. Radioactive tracing and/or use of vital staining enable the identification of the regional ganglionar group towards which the primary lesion is draining. The technique of sentinel lymph node identification and biopsy by means of radioactive tracing includes: - pre-surgical lymphoscintigraphy, - identification of the sentinel lymph node and its excisional biopsy, - intra-operative histopathological examination and immunohistochemical stains of the sentinel lymph node. Regional lymphadenectomy serves two major purposes: - diagnosis (axillary lymph node invasion represents an important prognostic factor) and therapeutic (to ensure local control of the disease). Regional lymph node invasion in breast cancer is directly related to the primary tumour size. In the less advanced stages (T1), as there is rarely invasion of the axillary lymph nodes, lymphadenectomy can be avoided in most cases. The paper presents the refinement of the technique, the validation of the method for the identification and biopsy of the sentinel lymph node in breast cancer using Tc99 and the intra-operative use of NEOPROBE 2000 gamma camera at the 'Prof. Dr. Alexandru Trestioreanu' Oncological Institute in Bucharest. 93 patients with primary breast cancer (T1, T2, N0

  14. EVALUATION OF THE COMPUTED TOMOGRAPHIC "SENTINEL CLOT SIGN" TO IDENTIFY BLEEDING ABDOMINAL ORGANS IN DOGS WITH HEMOABDOMEN.

    Science.gov (United States)

    Specchi, Swan; Auriemma, Edoardo; Morabito, Simona; Ferri, Filippo; Zini, Eric; Piola, Valentina; Pey, Pascaline; Rossi, Federica

    2017-01-01

    The CT "sentinel clot sign" has been defined as the highest attenuation hematoma adjacent to a bleeding organ in humans with hemoabdomen. The aims of this retrospective descriptive multicenter study were to describe CT findings in a sample of dogs with surgically or necropsy confirmed intra-abdominal bleeding and determine prevalence of the "sentinel clot sign" adjacent to the location of bleeding. Medical records between 2012 and 2014 were searched for dogs with hemoabdomen and in which the origin of the bleeding was confirmed either with surgery or necropsy. Retrieved CT images were reviewed for the presence and localization of the "sentinel clot sign," HU measurements of the "sentinel clot sign" and hemoabdomen, and presence of extravasation of contrast media within the abdominal cavity. Nineteen dogs were included. Three dogs were excluded due to the low amount of blood that did not allow the identification of a "sentinel clot sign." A "sentinel clot sign" was detected in the proximity of the confirmed bleeding organ in 14/16 (88%) of the patients. The mean HU of the "sentinel clot sign" was 56 (range: 43-70) while that of the hemoabdomen was 34 (range: 20-45). Active hemorrhage was identified as extravasation of contrast medium within the peritoneal cavity from the bleeding organ in three dogs. In conclusion, the CT "sentinel clot sign" may be helpful for identifying the source of bleeding in dogs with hemoabdomen. © 2016 American College of Veterinary Radiology.

  15. A Precise Visual Method for Narrow Butt Detection in Specular Reflection Workpiece Welding

    Directory of Open Access Journals (Sweden)

    Jinle Zeng

    2016-09-01

    Full Text Available During the complex path workpiece welding, it is important to keep the welding torch aligned with the groove center using a visual seam detection method, so that the deviation between the torch and the groove can be corrected automatically. However, when detecting the narrow butt of a specular reflection workpiece, the existing methods may fail because of the extremely small groove width and the poor imaging quality. This paper proposes a novel detection method to solve these issues. We design a uniform surface light source to get high signal-to-noise ratio images against the specular reflection effect, and a double-line laser light source is used to obtain the workpiece surface equation relative to the torch. Two light sources are switched on alternately and the camera is synchronized to capture images when each light is on; then the position and pose between the torch and the groove can be obtained nearly at the same time. Experimental results show that our method can detect the groove effectively and efficiently during the welding process. The image resolution is 12.5 μm and the processing time is less than 10 ms per frame. This indicates our method can be applied to real-time narrow butt detection during high-speed welding process.

  16. Lithological Classification Using Sentinel-2A Data in the Shibanjing Ophiolite Complex in Inner Mongolia, China

    Directory of Open Access Journals (Sweden)

    Wenyan Ge

    2018-04-01

    Full Text Available As a source of data continuity between Landsat and SPOT, Sentinel-2 is an Earth observation mission developed by the European Space Agency (ESA, which acquires 13 bands in the visible and near-infrared (VNIR to shortwave infrared (SWIR range. In this study, a Sentinel-2A imager was utilized to assess its ability to perform lithological classification in the Shibanjing ophiolite complex in Inner Mongolia, China. Five conventional machine learning methods, including artificial neural network (ANN, k-nearest neighbor (k-NN, maximum likelihood classification (MLC, random forest classifier (RFC, and support vector machine (SVM, were compared in order to find an optimal classifier for lithological mapping. The experiment revealed that the MLC method offered the highest overall accuracy. After that, Sentinel-2A image was compared with common multispectral data ASTER and Landsat-8 OLI (operational land imager for lithological mapping using the MLC method. The comparison results showed that the Sentinel-2A imagery yielded a classification accuracy of 74.5%, which was 2.5% and 5.08% higher than those of the ASTER and OLI imagery, respectively, indicating that Sentinel-2A imagery is adequate for lithological discrimination, due to its high spectral resolution in the VNIR to SWIR range. Moreover, different data combinations of Sentinel-2A + ASTER + DEM (digital elevation model and OLI + ASTER + DEM data were tested on lithological mapping using the MLC method. The best mapping result was obtained from Sentinel-2A + ASTER + DEM dataset, demonstrating that OLI can be replaced by Sentinel-2A, which, when combined with ASTER, can achieve sufficient bandpasses for lithological classification.

  17. Infected Donor Biomass and Active Feeding Increase Waterborne Transmission of Ichthyophonus sp. to Rainbow Trout Sentinels.

    Science.gov (United States)

    LaPatra, S E; Kocan, R M

    2016-06-01

    The precise nature of Ichthyophonus sp. transmission among wild fishes has eluded description for over a century. Transmission among piscivores is direct, via ingestion of infected prey, but there is also evidence for waterborne transmission between infected and uninfected individuals. Transmission among planktivores is believed to be via a waterborne infectious cell, but definitive proof of this mechanism has not been forthcoming. To explore possible mechanisms of transmission we used Rainbow Trout Oncorhynchus mykiss as a model system and examined the consequence of housing infected donor fish with uninfected (sentinel) fish, without physical contact. We examined two variables linked to transmission: (1) feeding and nonfeeding sentinel fish, and (2) biomass of infected donor fish. Specific-pathogen free sentinel trout were placed in fine-mesh baskets suspended in tanks containing varying numbers of larger Ichthyophonus-infected donor fish and held for 10 weeks, during which time they were examined by in vitro explant culture for the presence of Ichthyophonus. Treatment groups consisted of fed and unfed sentinels housed with infected donors of increasing biomass. After 10 weeks infection prevalence in fed sentinels was significantly higher than in unfed sentinels, and Ichthyophonus was detected earlier in fed fish than in unfed fish. There was no correlation between infection prevalence and donor biomass in fed sentinels, but there was a strong correlation between infection prevalence and increasing donor biomass in unfed sentinels. These data suggest that Ichthyophonus is maintained in wild fish populations by two distinct mechanisms: (1) waterborne infectious cells ingested directly from the water by planktivores, and (2) both infected prey and waterborne infectious cells ingested by piscivores. Received November 13, 2015; accepted February 13, 2016.

  18. Special metallurgy - the electrical butt-welding by flashing of sintered magnesium-magnesium oxide composites (1963)

    International Nuclear Information System (INIS)

    Charleux, J.

    1963-01-01

    Electrical resistance welding has become quite important since World War II because of the need of a high yield in aeronautical production. Progress has been due in particular to the improvements made in electronically controlled apparatus making possible the automatic control of welding. For the butt-welding of sections requiring either a high production rate or a high quality weld, the flash butt-welding system has been very much developed these last few years. The use of this welding method is of great importance in the field of the bonding of oxidisable metals such as magnesium or aluminium and its alloys, because the welded joint is free from oxides. This study consists of general considerations on the flash-welding process with regard to temperature distribution in the parts during welding, and to electrical phenomena connected with flashing. Besides this general or theoretical section, we have applied the welding process to the bonding of sintered magnesium, a magnesium-magnesium oxide composite, whose use as a structural element in nuclear reactors is considered. (author) [fr

  19. 76 FR 19788 - Carbon Steel Butt-Weld Pipe Fittings From Brazil, China, Japan, Taiwan, and Thailand

    Science.gov (United States)

    2011-04-08

    ...)] Carbon Steel Butt-Weld Pipe Fittings From Brazil, China, Japan, Taiwan, and Thailand Determinations On... fittings from Brazil, China, Japan, Taiwan, and Thailand would be likely to lead to continuation or recurrence of material injury to an industry in the United States within a reasonably foreseeable time. \\1...

  20. Intraflow structures of the Cohassett flow at east Sentinel Gap and Sentinel Mountain

    International Nuclear Information System (INIS)

    Cross, R.W.; Fairchild, K.R.

    1988-04-01

    This report presents the results of outcrop intraflow structure studies in the Cohassett flow at east Sentinel Gap and Sentinel Mountain on the northwestern margin of the Pasco Basin. This study is the first of several Cohassett outcrop studies. The studies will aid in characterizing intraflow structures of the Cohassett flow to support design and construction and to aid in assessing the performance of a possible high-level nuclear waste repository in the subsurface of the reference repository location at the Hanford Site. A total of twenty-four intraflow structure sections of the Cohassett flow were measured at two, adjacent study areas. The measured sections provide positions, thicknesses, and descriptions of every intraflow structure encountered within the Cohassett flow. Graphic logs of each section display the sequence of intraflow structures per measured section. Correlation diagrams depict interpretations of the lateral continuity and thickness variations of each intraflow structure across the total of 6 km of the two study areas. Consistencies of intraflow structures are observed across the study area. The Cohassett flow interior in outcrop is consistently thick and never thins to less than 51 m. The flow interior is interpreted as laterally continuous across the study areas, and no features are observed to interrupt its horizontal extent. Based on the field observations, there is interpreted lateral continuity of packets of intraflow structures within the flow interior. 20 refs., 24 figs

  1. Zika beyond the Americas: Travelers as sentinels of Zika virus transmission. A GeoSentinel analysis, 2012 to 2016

    NARCIS (Netherlands)

    Leder, Karin; Grobusch, Martin P.; Gautret, Philippe; Chen, Lin H.; Kuhn, Susan; Lim, Poh Lian; Yates, Johnnie; McCarthy, Anne E.; Rothe, Camilla; Kato, Yasuyuki; Bottieau, Emmanuel; Huber, Kristina; Schwartz, Eli; Stauffer, William; Malvy, Denis; Shaw, Marc T. M.; Rapp, Christophe; Blumberg, Lucille; Jensenius, Mogens; van Genderen, Perry J. J.; Hamer, Davidson H.

    2017-01-01

    Zika virus (ZIKV) was first isolated in Africa; decades later, caused large outbreaks in the Pacific, and is considered endemic in Asia. We aim to describe ZIKV disease epidemiology outside the Americas, the importance of travelers as sentinels of disease transmission, and discrepancies in travel

  2. Estimating Velocities of Glaciers Using Sentinel-1 SAR Imagery

    Science.gov (United States)

    Gens, R.; Arnoult, K., Jr.; Friedl, P.; Vijay, S.; Braun, M.; Meyer, F. J.; Gracheva, V.; Hogenson, K.

    2017-12-01

    In an international collaborative effort, software has been developed to estimate the velocities of glaciers by using Sentinel-1 Synthetic Aperture Radar (SAR) imagery. The technique, initially designed by the University of Erlangen-Nuremberg (FAU), has been previously used to quantify spatial and temporal variabilities in the velocities of surging glaciers in the Pakistan Karakoram. The software estimates surface velocities by first co-registering image pairs to sub-pixel precision and then by estimating local offsets based on cross-correlation. The Alaska Satellite Facility (ASF) at the University of Alaska Fairbanks (UAF) has modified the software to make it more robust and also capable of migration into the Amazon Cloud. Additionally, ASF has implemented a prototype that offers the glacier tracking processing flow as a subscription service as part of its Hybrid Pluggable Processing Pipeline (HyP3). Since the software is co-located with ASF's cloud-based Sentinel-1 archive, processing of large data volumes is now more efficient and cost effective. Velocity maps are estimated for Single Look Complex (SLC) SAR image pairs and a digital elevation model (DEM) of the local topography. A time series of these velocity maps then allows the long-term monitoring of these glaciers. Due to the all-weather capabilities and the dense coverage of Sentinel-1 data, the results are complementary to optically generated ones. Together with the products from the Global Land Ice Velocity Extraction project (GoLIVE) derived from Landsat 8 data, glacier speeds can be monitored more comprehensively. Examples from Sentinel-1 SAR-derived results are presented along with optical results for the same glaciers.

  3. Assessment of NDE Methods on Inspection of HDPE Butt Fusion Piping Joints for Lack of Fusion with Validation from Mechanical Testing

    International Nuclear Information System (INIS)

    Anderson, Michael T.; Cinson, Anthony D.; Crawford, Susan L.; Doctor, Steven R.; Moran, Traci L.; Watts, Michael W.

    2010-01-01

    Studies at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, are being conducted to evaluate nondestructive examinations (NDE) coupled with mechanical testing of butt fusion joints in high-density polyethylene (HDPE) pipe for assessing lack of fusion. The work provides information to the U.S. Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from preliminary assessments using ultrasonic and microwave nondestructive techniques and mechanical testing with the high-speed tensile impact test and the side-bend test for determining joint integrity. A series of butt joints were fabricated in 3408, 12-in. IPS DR-11 HDPE material by varying the fusion parameters to create good joints and joints containing a range of lack-of-fusion conditions. Six of these butt joints were volumetrically examined with time-of-flight diffraction (TOFD), phased-array (PA) ultrasound, and the Evisive microwave system. The outer-diameter weld beads were removed for the microwave inspection. In two of the four pipes, both the outer and inner weld beads were removed and the pipe joints re-evaluated. The pipes were sectioned and the joints destructively evaluated with the side-bend test by cutting portions of the fusion joint into slices that were planed and bent. The last step in this limited study will be to correlate the fusion parameters, nondestructive, and destructive evaluation results to validate the effectiveness of what each NDE technology detects and what each does not detect. The results of the correlation will be used in identifying any future work that is needed.

  4. In-process monitoring and adaptive control for gap in micro butt welding with pulsed YAG laser

    International Nuclear Information System (INIS)

    Kawahito, Yousuke; Kito, Masayuki; Katayama, Seiji

    2007-01-01

    A gap is one of the most important issues to be solved in laser welding of a micro butt joint, because the gap results in welding defects such as underfilling or a non-bonded joint. In-process monitoring and adaptive control has been expected as one of the useful procedures for the stable production of sound laser welds without defects. The objective of this research is to evaluate the availability of in-process monitoring and adaptive control in micro butt welding of pure titanium rods with a pulsed neodymium : yttrium aluminium garnet (Nd : YAG) laser beam of a 150 μm spot diameter. It was revealed that a 45 μm narrow gap was detected by the remarkable jump in a reflected light intensity due to the formation of the molten pool which could bridge the gap. Heat radiation signal levels increased in proportion to the sizes of molten pools or penetration depths for the respective laser powers. As for adaptive control, the laser peak power was controlled on the basis of the reflected light or the heat radiation signals to stably produce a sound deeply penetrated weld reduced underfilling. In the case of a 100 μm gap, the underfilling was greatly reduced by half smaller than those made with a conventional rectangular pulse shape in seam welding as well as spot welding with a pulsed Nd : YAG laser beam. Consequently, the adaptive control of the laser peak power on the basis of in-process monitoring could reduce the harmful effects due to a gap in micro butt laser welding with a pulsed laser beam

  5. CTC Sentinel. Volume 9, Issue 3

    Science.gov (United States)

    2016-03-01

    for the Caliphate,” CTC Sentinel 8:8 (2015). 28 Nicolas Beau, “Syrte, une cinquantaine de français aux cotés de Daech,” MondeAfrique, February 12...scale.”2 Earlier this month, Assistant Commissioner Mark Rowley, who oversees counterterrorism efforts for the London Metropoli- tan Police, warned

  6. A Study of Sentinel-1 TOPS Mode Co-registration

    Directory of Open Access Journals (Sweden)

    WU Wenhao

    2017-09-01

    Full Text Available The TOPS imaging mode is the default operation mode of Sentinel-1 satellite, an overall azimuth coregistration accuracy of better than 0.001 pixels is required for this configuration in order to achieve the interferometric phase bias is less than three degrees. Based on the high accuracy of Sentinel-1 orbital information, this paper demonstrates a sufficiently high coregistration accuracy is able to be achieved by geometrical coregistration algorithm, which satisfies the pre-requirement for estimating the residual coregistration error by enhanced spectral diversity method. Based on DORIS open source software, a coregistration approach for Sentinel-A TOPS mode is implemented by an algorithm of geometric prediction of the shifts using precise orbit information, and an improvement on coregistration processing is achieved by enhanced spectral diversity. An interferometric phase jump between two Bursts could be caused by surface deformation in azimuth direction, and introduce a disturbance when estimating the residual coregistration error by enhanced spectral diversity method. In this paper, based on related theory analysis and real data processing test, an outlier detection estimation method is proposed to reduce the disturbance of enhanced spectral diversity coregistration method, which is caused by phase jumps.

  7. Sentinel lymph node procedure is highly accurate in squamous cell carcinoma of the vulva

    NARCIS (Netherlands)

    de Hullu, JA; Hollema, H; Piers, DA; Verheijen, RHM; van Diest, PJ; Mourits, MJE; Aalders, JG; van der Zee, AGJ

    Purpose: To determine the diagnostic accuracy of the sentinel lymph node procedure in patients with squamous cell carcinoma of the vulva and to investigate whether step sectioning and immunohistochemistry of sentinel lymph nodes increase the sensitivity for detection of metastases. Patients and

  8. Noble Gas Isotope Evidence for Mantle Volatiles in the Cu-Mo Porphyry and Main Stage Polymetallic Veins at Butte, Montana

    Science.gov (United States)

    Hofstra, A. H.; Rusk, B. G.; Manning, A. H.; Hunt, A. G.; Landis, G. P.

    2017-12-01

    Recent studies suggest that volatiles released from mafic intrusions may be important sources of heat, sulfur, and metals in porphyry Cu-Mo-Au and epithermal Au-Ag deposits associated with intermediate to silicic stocks. The huge Cu-Mo porphyry and Main Stage polymetallic vein deposits at Butte are well suited to test this hypothesis because there is no geologic or isotopic evidence of basaltic intrusions in the mine or drill holes. The Butte porphyry-vein system is associated with quartz monzonite stocks and dikes within the southwest part of the Late Cretaceous Boulder batholith. The Boulder batholith was emplaced into Mesoproterozoic to Mesozoic sedimentary rocks and Late Cretaceous volcanic rocks. The Boulder batholith and Butte intrusions have Sri and eNd values indicative of crustal contamination. Eu and Ce anomalies in zircon from Butte intrusions provide evidence of oxidation due to magma degassing. To ascertain the source of volatiles in this system, 11 samples from the Cu-Mo porphyry and 16 from Main Stage veins were selected. The isotopic composition of Ar, Ne, and He extracted from fluid inclusions in quartz, magnetite, pyrite, chalcopyrite, sphalerite, galena, enargite, and covellite were determined. Helium isotopes exceed blank levels in all samples and Ne and Ar in some samples. On a 38Ar/36Ar vs. 40Ar/36Ar diagram, data plot near air. On a 20Ne/22Ne vs. 21Ne/22Ne diagram, data extend from air along the trajectories of OIB and MORB. On a 36Ar/4He vs. 3He/4He RA diagram, data extend from crust toward the air-mantle mixing line. The maximum 3He/4He RA values in the Cu-Mo porphyry (2.86) and Main Stage veins (3.46) are from pyrite and these values correspond to 36 and 43 % mantle helium. The Ne and He results show that fluid inclusions contain volatiles discharged from mantle magmas and that these volatiles were diluted by groundwater containing He derived from country rocks. Despite the lack of mafic intrusions in the Butte magmatic center, noble gas

  9. [Japanese sentinel project and contribution of laboratory medicine].

    Science.gov (United States)

    Nakashima, Naoki

    2013-06-01

    Ordinary passive surveillance (generally spontaneous reporting) of adverse effects of medical products is not enough to manage medical risks/safety. The Japanese government, following the "sentinel initiative" by the US government, started the "Japanese sentinel project" as an active surveillance of medical products with the Pharmaceuticals and Medical Devices Agency(PMDA). Using entire prescription data in the hospital information system, data on laboratory examinations, diagnosis, and therapy specific to an adverse effect are checked by detecting differences between before and after prescription of a specific medical product to extract adverse effects and calculate their correct frequency in the surveillance. The project uses standard masters and protocols to analyze data among medial institutes by installation of the SS-MIX standard storage system. Ten hospitals were selected in 2011 to join the project, and the entire system and network will be implemented in those hospitals and PMDA until 2013 fiscal year. JLAC10 is used in the project as the laboratory examination code of the Japanese Society of Laboratory Medicine. Many incorrect coding and ambiguous coding rules were found by voluntary surveillance of 6 of the 10 hospitals in the project. Thus, the Council on Standardized Master Operation of Clinical Laboratory Examinations will launch in 2013 to improve and maintain JLAC10, which is essential not only for the Japanese sentinel project but also for data utilization by many other projects.

  10. Manatees as sentinels of marine ecosystem health: are they the 2000-pound canaries?

    Science.gov (United States)

    Bonde, R.K.; Aguirre, A.A.; Powell, J.

    2004-01-01

    The order Sirenia is represented by three species of manatees and one species of dugong distributed in tropical and subtropical regions of the world and considered vulnerable to extinction. The sentinel species concept is useful to identify indicators of the environment and may reflect the quality of health in marine ecosystems. The single species approach to evaluate ecological health may provide a series of “snap shots” of environmental changes to determine if animal, human, or ecosystem health may be affected. Under this concept, marine vertebrates may be good integrators of changes over space and time, and excellent sentinels of ecosystem health. Based on their life history, manatees may or may not be ideal sentinels, as they are robust, long-lived species and appear remarkably resilient to natural disease and the effects of human-related injury and trauma. These characteristics might be the result of an efficient and responsive immune system compared to other marine mammals. Although relatively immune to infectious agents, manatees face other potentially serious threats, including epizootic diseases and pollution while in large aggregations. Manatees can serve as excellent sentinels of harmful algal blooms due to their high sensitivity, specifically to brevetoxicosis, which has caused at least two major die-offs in recent times. Threats to manatees worldwide, such as illegal hunting and boat collisions, are increasing. Habitat is being lost at an alarming rate and the full effects of uncontrolled human population growth on the species are unknown. The manatee may serve as a sentinel species, prognosticating the deleterious effects of unhealthy marine and aquatic ecosystems on humans. We have identified a number of critical research needs and opportunities for transdisciplinary collaboration that could help advance the use of the sentinel species concept in marine ecosystem health and monitoring of disease emergence using our knowledge on these magnificent

  11. Sentinel node localisation using pre-operative lymphoscintigraphy and intraoperative gamma probe in early oral cavity cancer

    International Nuclear Information System (INIS)

    Ikram, M.; Akhtar, S.; Junaid, M.; Dhari, T.; Zaman, M.U.; Hussain, R.

    2013-01-01

    Objectives: To assess the diagnostic value of sentinel lymph node localisation using pre-operative lymphoscintigraphy and intra-operative gamma probe radio localisation in Pakistani patients suffering from early stage squamous cell carcinoma of the oral cavity. Methods: The prospective case series was conducted between September 2007 and April 2010 at the Aga Khan University Hospital, Karachi. It comprised patients with T1 and T2 oral cavity cancer with clinically and radiologically negative neck. Pre-operative lymphoscintigraphy was performed one day before surgery and intra-operative gamma probe was used to detect sentinel node. Final histo-pathological evaluation was taken as the gold standard. Results: The study comprised 42 patients: 32(76%) males and 10(24%) females. The primary tumour site was buccal mucosa in 25 (60%) patients, and tongue in 17 (40%). Sentinel lymph node was detected in 38 (90%) patients. On final histopathological identification, 7 (17%) patients had cancer in the neck nodes. In all patients with metastasis, sentinel lymph node technique correctly identified the involved neck level. None of the patients revealed metastasis in non-sentinel lymph nodes. Conclusion:Evidence suggested the use of sentinel node biopsy in patients with head and neck squamous cell carcinoma. (author)

  12. Sentinel lymph node identification with magnetic nanoparticles

    NARCIS (Netherlands)

    Pouw, Joost Jacob

    2016-01-01

    Most solid malignancies have a tendency to spread through the lymphatic system to locoregional lymph nodes. Presence of metastasis is an important prognostic factor, and is used to determine the optimal treatment of the patient. The sentinel lymph nodes (SLNs) receive direct lymphatic drainage from

  13. Mulig forbedret behandling af kolorektal cancer med sentinel lymph node-diagnostik

    DEFF Research Database (Denmark)

    Burgdorf, Stefan Kobbelgaard; Eriksen, Jens Ravn; Gögenur, Ismail

    2014-01-01

    Possibly improved treatment of colorectal cancer by sentinel lymph node mapping Prognosis for colorectal cancer is dependent on radical surgical intervention. Chemotherapy in patients with advanced disease has improved the survival. A considerable proportion of the patients going through radical...... surgery will subsequently relapse. Adjuvant chemotherapy is reserved for patients with lymph node metastases, why undetected malignant lymph nodes will result in understaging and exclusion from the possible benefit of adjuvant chemotherapy. With sentinel lymph node mapping it may be possible to detect...

  14. Riparian spiders as sentinels of polychlorinated biphenyl contamination across heterogeneous aquatic ecosystems

    Science.gov (United States)

    Kraus, Johanna M.; Gibson, Polly P.; Walters, David M.; Mills, Marc A.

    2017-01-01

    Riparian spiders are being used increasingly to track spatial patterns of contaminants in and fluxing from aquatic ecosystems.However, our understanding of the circumstances under which spiders are effective sentinels of aquatic pollution is limited. The present study tests the hypothesis that riparian spiders may be effectively used to track spatial patterns of sediment pollution by polychlorinated biphenyls (PCBs) in aquatic ecosystems with high habitat heterogeneity. The spatial pattern of ΣPCB concentrations in 2 common families of riparian spiders sampled in 2011 to 2013 generally tracked spatial variation in sediment ΣPCBs across all sites within the Manistique River Great Lakes Area of Concern (AOC), a rivermouth ecosystem located on the south shore of the Upper Peninsula, Manistique (MI,USA) that includes harbor, river, backwater, and lake habitats. Sediment ΣPCB concentrations normalized for total organic carbon explained 41% of the variation in lipid-normalized spider ΣPCB concentrations across 11 sites. Furthermore, 2 common riparian spider taxa (Araneidae and Tetragnathidae) were highly correlated (r2> 0.78) and had similar mean ΣPCB concentrations when averaged acrossall years. The results indicate that riparian spiders may be useful sentinels of relative PCB availability to aquatic and riparian food webs in heterogeneous aquatic ecosystems like rivermouths where habitat and contaminant variability may make the use of aquatic taxa lesseffective. Furthermore, the present approach appears robust to heterogeneity in shoreline development and riparian vegetation that support different families of large web-building spiders. Environ Toxicol Chem 2016;9999:1–9. Published 2016 Wiley Periodicals, Inc. on behalf of SETAC. This article is a US government work and, as such, is in the public domain in the United States of America.

  15. Mountain Plant Community Sentinels: AWOL

    Science.gov (United States)

    Malanson, G. P.

    2017-12-01

    Mountain plant communities are thought to be sensitive to climate change. Because climatic gradients are steep on mountain slopes, the spatial response of plant communities to climate change should be compressed and easier to detect. These expectations have led to identifying mountain plant communities as sentinels for climate change. This idea has, however, been criticized. Two critiques, for alpine treeline and alpine tundra, are rehearsed and supplemented. The critique of alpine treeline as sentinel is bolstered with new model results on the confounding role of dispersal mechanisms and sensitivity to climatic volatility. In alpine tundra, for which background turnover rates have yet to be established, community composition may reflect environmental gradients only for extremes where effects of climate are most indirect. Both plant communities, while primarily determined by energy at broad scales, may respond to water as a proximate driver at local scales. These plant communities may not be in equilibrium with climate, and differently scaled time lags may mean that ongoing vegetation change may not signal ongoing climate change (or lack thereof). In both cases a double-whammy is created by scale dependence for time lags and for drivers leading to confusion, but these cases present opportunities for insights into basic ecology.

  16. Development and field evaluation of the sentinel mosquito arbovirus capture kit (SMACK)

    OpenAIRE

    Johnson, Brian J.; Kerlin, Tim; Hall-Mendelin, Sonja; van den Hurk, Andrew F.; Cortis, Giles; Doggett, Stephen L.; Toi, Cheryl; Fall, Ken; McMahon, Jamie L.; Townsend, Michael; Ritchie, Scott A.

    2015-01-01

    Background Although sentinel animals are used successfully throughout the world to monitor arbovirus activity, ethical considerations and cross-reactions in serological assays highlight the importance of developing viable alternatives. Here we outline the development of a passive sentinel mosquito arbovirus capture kit (SMACK) that allows for the detection of arboviruses on honey-baited nucleic acid preservation cards (Flinders Technology Associates; FTA®) and has a similar trap efficacy as s...

  17. 75 FR 430 - Notice of Intent To Prepare an Environmental Impact Statement for the Sigurd-Red Butte...

    Science.gov (United States)

    2010-01-05

    ...; UTU-83067] Notice of Intent To Prepare an Environmental Impact Statement for the Sigurd-Red Butte...) Cedar City Field Office, Cedar City, Utah, intends to prepare an Environmental Impact Statement (EIS... Fishlake National Forests), State of Utah, Millard County, Sevier County, Beaver County, Utah Division of...

  18. Developments in the Aerosol Layer Height Retrieval Algorithm for the Copernicus Sentinel-4/UVN Instrument

    Science.gov (United States)

    Nanda, Swadhin; Sanders, Abram; Veefkind, Pepijn

    2016-04-01

    The Sentinel-4 mission is a part of the European Commission's Copernicus programme, the goal of which is to provide geo-information to manage environmental assets, and to observe, understand and mitigate the effects of the changing climate. The Sentinel-4/UVN instrument design is motivated by the need to monitor trace gas concentrations and aerosols in the atmosphere from a geostationary orbit. The on-board instrument is a high resolution UV-VIS-NIR (UVN) spectrometer system that provides hourly radiance measurements over Europe and northern Africa with a spatial sampling of 8 km. The main application area of Sentinel-4/UVN is air quality. One of the data products that is being developed for Sentinel-4/UVN is the Aerosol Layer Height (ALH). The goal is to determine the height of aerosol plumes with a resolution of better than 0.5 - 1 km. The ALH product thus targets aerosol layers in the free troposphere, such as desert dust, volcanic ash and biomass during plumes. KNMI is assigned with the development of the Aerosol Layer Height (ALH) algorithm. Its heritage is the ALH algorithm developed by Sanders and De Haan (ATBD, 2016) for the TROPOMI instrument on board the Sentinel-5 Precursor mission that is to be launched in June or July 2016 (tentative date). The retrieval algorithm designed so far for the aerosol height product is based on the absorption characteristics of the oxygen-A band (759-770 nm). The algorithm has heritage to the ALH algorithm developed for TROPOMI on the Sentinel 5 precursor satellite. New aspects for Sentinel-4/UVN include the higher resolution (0.116 nm compared to 0.4 for TROPOMI) and hourly observation from the geostationary orbit. The algorithm uses optimal estimation to obtain a spectral fit of the reflectance across absorption band, while assuming a single uniform layer with fixed width to represent the aerosol vertical distribution. The state vector includes amongst other elements the height of this layer and its aerosol optical

  19. Role of sentinel lymph node biopsy in oral cancer.

    Science.gov (United States)

    Calabrese, L; Bruschini, R; Ansarin, M; Giugliano, G; De Cicco, C; Ionna, F; Paganelli, G; Maffini, F; Werner, J A; Soutar, D

    2006-12-01

    Squamous cell carcinoma of the oral cavity represents about 2% of all malignant neoplasms and 47% of those developing in the head and neck area. The tongue is the most common site involved, and this incidence is increasing mainly in young people, possibly related to human papilloma virus infections. Prognosis depends on the stage: the 5-year survival rate of tongue squamous cell carcinoma, whatever the T stage, is 73% in pN0 cases, 40% in patients with positive nodes without extracapsular spread (pNl ECS-), and 29% when nodes are metastatic with extracapsular spread (pNl ECS+: p > or = 0.0001). Nodal micrometastases (cN0 pN1) are found in up to 50% of cN0 tongue squamous cell carcinoma patients operated on the neck. At present, no clinical, imaging staging modalities or biological markers are available to diagnose nodal micrometastases. The sentinel node biopsy has been tested since 1996 in order to find a solution to this problem. The sentinel node is the first node reached by the lymphatic stream, assuming an orderly and sequential drainage from the tumour site, and should be predictive of the nodal stage. According to the literature, sentinel node biopsy is a reliable technique in selected cN0 cases, but the procedure is still experimental and should not be performed outside validation trials. Successful application of sentinel node biopsy in the head and neck region requires surgical experience and specific technical devices, including pre-operative lymphoscintigraphy and intra-operative gamma-probe. Moreover, dynamic lymphoscintigraphy seems to be able to show the lymphatic stream from the primary tumour and could allow a selective neck dissection to be tailored thus reducing the related morbidity.

  20. Survey of Hyperspectral Earth Observation Applications from Space in the Sentinel-2 Context

    Directory of Open Access Journals (Sweden)

    Julie Transon

    2018-01-01

    Full Text Available In the last few decades, researchers have developed a plethora of hyperspectral Earth Observation (EO remote sensing techniques, analysis and applications. While hyperspectral exploratory sensors are demonstrating their potential, Sentinel-2 multispectral satellite remote sensing is now providing free, open, global and systematic high resolution visible and infrared imagery at a short revisit time. Its recent launch suggests potential synergies between multi- and hyper-spectral data. This study, therefore, reviews 20 years of research and applications in satellite hyperspectral remote sensing through the analysis of Earth observation hyperspectral sensors’ publications that cover the Sentinel-2 spectrum range: Hyperion, TianGong-1, PRISMA, HISUI, EnMAP, Shalom, HyspIRI and HypXIM. More specifically, this study (i brings face to face past and future hyperspectral sensors’ applications with Sentinel-2’s and (ii analyzes the applications’ requirements in terms of spatial and temporal resolutions. Eight main application topics were analyzed including vegetation, agriculture, soil, geology, urban, land use, water resources and disaster. Medium spatial resolution, long revisit time and low signal-to-noise ratio in the short-wave infrared of some hyperspectral sensors were highlighted as major limitations for some applications compared to the Sentinel-2 system. However, these constraints mainly concerned past hyperspectral sensors, while they will probably be overcome by forthcoming instruments. Therefore, this study is putting forward the compatibility of hyperspectral sensors and Sentinel-2 systems for resolution enhancement techniques in order to increase the panel of hyperspectral uses.

  1. Features of residual stresses in duplex stainless steel butt welds

    Science.gov (United States)

    Um, Tae-Hwan; Lee, Chin-Hyung; Chang, Kyong-Ho; Nguyen Van Do, Vuong

    2018-04-01

    Duplex stainless steel finds increasing use as an alternative to austenitic stainless steel, particularly where chloride or sulphide stress corrosion cracking is of primary concern, due to the excellent combination of strength and corrosion resistance. During welding, duplex stainless steel does not create the same magnitude or distribution of weld-induced residual stresses as those in welded austenitic stainless steel due to the different physical and mechanical properties between them. In this work, an experimental study on the residual stresses in butt-welded duplex stainless steel is performed utilizing the layering technique to investigate the characteristics of residual stresses in the weldment. Three-dimensional thermos-mechanical-metallurgical finite element analysis is also performed to confirm the residual stress measurements.

  2. Tc-99m Diphosphonate as a Potential Radiotracer to Detect Sentinel Lymph Nodes in Patients with Breast Cancer

    International Nuclear Information System (INIS)

    Yang, You Jung; Lim, Sung Jig; Song, Jeong Yoon

    2010-01-01

    To evaluate the potential of Tc-99m diphosphonate as a tracer for sentinel lymph node biopsy in breast cancer. Lymphoscintigraphy of 35 patients (50.9±10.2 years) with breast cancer were acquired after administering a subauroral intradermal injection of Tc-99m diphosphonate 18 h before surgery. Static images were taken within 15 min (early phase) and 15 h after injection (delayed phase). The lymphoscintigraphy identification rate was defined as the percentage of subjects studied with visible foci at axillae. Sentinel lymph node biopsies were performed using a gamma probe and by blue dye injection. Any node that was radioactive or stained with blue dye was labeled as a sentinel lymph node. Lymph nodes without radioactivity or blue dye staining were defined as non sentinel lymph nodes. The intraoperative identification rate was defined as the percentage of patients with a radioactive sentinel lymph node. Percentages of lymphoid cells expressing S-100, CD83, and CD1a were compared. The lymphoscintigraphy identification rate was 94.3% (33/35) during the early phase and 96.9% (31/32) during the delayed phase, whereas the intraoperative identification rate was 94.3% (33/35). The mean percentages of lymphoid cells that stained positively for S-100 or CD83 were lower in sentinel lymph nodes than in non sentinel lymph nodes (1.5% vs. 9.0% for S-100, and 4.5% vs. 9.3% for CD83, respectively, p=0.0286). The mean percentages of lymphoid cells in sentinel lymph nodes and non-sentinel lymph nodes expressing CD1a were 3.3% and 7.0%, respectively (p=ns). Conclusions Tc-99m diphosphonate can reliably detect regional lymph nodes in breast cancer.

  3. Preventing childhood obesity: the sentinel site for obesity prevention in Victoria, Australia.

    Science.gov (United States)

    Bell, A Colin; Simmons, Anne; Sanigorski, Andrea M; Kremer, Peter J; Swinburn, Boyd A

    2008-12-01

    In spite of greater awareness of the need for action to reduce obesity, the evidence on sustainable community approaches to prevent childhood and adolescent obesity is surprisingly sparse. This paper describes the design and methodological components of the Sentinel Site for Obesity Prevention, a demonstration site in the Barwon-South West region of Victoria, Australia, that aims to build the programs, skills and evidence necessary to attenuate and eventually reverse the obesity epidemic in children and adolescents. The Sentinel Site for Obesity Prevention is based on a partnership between the region's university (Deakin University) and its health, education and local government agencies. The three basic foundations of the Sentinel Site are: multi-strategy, multi-setting interventions; building community capacity; and undertaking program evaluations and population monitoring. Three intervention projects have been supported that cover different age groups (preschool: 2-5 years, primary school: 5-12 years, secondary school: 13-17 years), but that have many characteristics in common including: community participation and ownership of the project; an intervention duration of at least 3 years; and full evaluations with impact (behaviours) and outcome measures (anthropometry) compared with regionally representative comparison populations. We recommend the Sentinel Site approach to others for successfully building evidence for childhood obesity prevention and stimulating action on reducing the epidemic.

  4. SENTINEL-1/2 DATA FOR SHIP TRAFFIC MONITORING ON THE DANUBE RIVER

    Directory of Open Access Journals (Sweden)

    I. Dana Negula

    2016-06-01

    Full Text Available After a long period of drought, the water level of the Danube River has significantly dropped especially on the Romanian sector, in July-August 2015. Danube reached the lowest water level recorded in the last 12 years, causing the blockage of the ships in the sector located close to Zimnicea Harbour. The rising sand banks in the navigable channel congested the commercial traffic for a few days with more than 100 ships involved. The monitoring of the decreasing water level and the traffic jam was performed based on Sentinel-1 and Sentinel-2 free data provided by the European Space Agency and the European Commission within the Copernicus Programme. Specific processing methods (calibration, speckle filtering, geocoding, change detection, image classification, principal component analysis, etc. were applied in order to generate useful products that the responsible authorities could benefit from. The Sentinel data yielded good results for water mask extraction and ships detection. The analysis continued after the closure of the crisis situation when the water reached the nominal level again. The results indicate that Sentinel data can be successfully used for ship traffic monitoring, building the foundation of future endeavours for a durable monitoring of the Danube River.

  5. Critical Gap distance in Laser Butt-welding

    DEFF Research Database (Denmark)

    Bagger, Claus; Olsen, Flemming Ove

    1999-01-01

    In a number of systematic laboratory experiments the critical gap distance that results in sound beads in laser butt welding is sought identified. By grinding the edges of the sheets, a number of "reference" welds are made and compared to the sheets with shear cut edges. In the tests the gap...... was set at 0.00, 0.02, 0.05, 0.08 and 0.10 mm. Mild steel (St 1203) with a thickness of 0.75 and 1.25 mm with and without zinc coating were analysed. A total of 120 welds were made at different welding speeds.As quality norm DIN 8563 was used to divide the welds into quality classes. A number of welds...... were also x-ray photographed.Of the weld combinations analysed 80 % were of high quality and 17 % of a non-acceptable quality. 90 % of the bad welds had a gap distance larger than 0.05 mm. The results showed that 85 % of the bad welds were shear cut and only 15 % grinded. Two third of the bad welds...

  6. Critical Gap distance in Laser Butt-welding

    DEFF Research Database (Denmark)

    Bagger, Claus; Olsen, Flemming Ove

    of "reference" welds are made and compared to sheets with the edges shear cut. The gap distance is precisely controlled by inserting spacers between the sheets. In the tests the gap is set at 0.00, 0.02, 0.05, 0.08 and 0.10 mm. Mild steel (St 1203) with thickness? of 0.75 and 1.25 mm with and without zinc......When butt-welding metal sheets with high power lasers the gap distance between the sheets determine the final quality of the seam. In a number of systematic laboratory experiments the critical gap distance that results in sound beads is identified. By grinding the edges of the sheets, a number...... coating were analysed. A total of 120 welds are made at different welding speeds.As quality norm DIN 8563 is used to divide the welds into quality classes. Since this norm only deals with surface defects a number of welds are also x-ray photographed.According to DIN 8563 the welds have classes of either B...

  7. SENTINEL trademark technical basis report for Limerick. Final report

    International Nuclear Information System (INIS)

    Burns, E.T.; Lee, L.K.; Mitman, J.T.; Vanover, D.E.; Wilson, D.K.

    1997-12-01

    PECO Energy in cooperation with the Electric Power Research Institute (EPRI) installed the SENTINEL trademark software at its Limerick Generating Station. This software incorporates models of the safety and support systems which are used to display the defense in depth present in the plant and a quantitative assessment of the plant risks during proposed on-line maintenance. During the past year, PECO Energy personnel have used this display to evaluate the safety of proposed on-line maintenance schedules. The report describes the motivation for and the development of the SENTINEL software. It describes the generation of Safety Function Assessment Trees and Plant Transient Assessment Trees and their use in evaluating the level of defense-in-depth of key plant safety functions and the susceptibility of the plant to critical transient events. Their results are displayed by color indicators ranging from green, through yellow and orange to red to show increasingly hazardous conditions. The report describes the use of the Limerick Probabilistic Safety Assessment within the SENTINEL code to calculate an instantaneous core damage frequency and the criteria by which this frequency is translated to a color indicator. Finally, the report describes the Performance Criteria Assessment which tracks and trends system/train unavailability to document conformance to the requirements of the Maintenance Rule

  8. Evaluating TIMP-1, Ki67, and HER2 as markers for non-sentinel node metastases in breast cancer patients with micrometastases to the sentinel node

    DEFF Research Database (Denmark)

    Tvedskov, Tove Filtenborg; Bartels, Annette; Jensen, Maj-Britt

    2011-01-01

    The aim was to investigate whether the biochemical prognostic markers TIMP-1, Ki67, and HER2 could predict metastatic spread to non-sentinel nodes (NSN) in breast cancer patients with micrometastases to sentinel node (SN). We included all breast cancer patients with micrometastases to SN operated...... between 2001 and 2007 at the Department of Breast Surgery, Herlev Hospital. The study was designed as a matched case-control study with 25 cases with micrometastases to SN and, in addition, metastatic spread to NSN and 50 matched controls with micrometastases to SN, but without NSN metastases. Patient...

  9. The Surveillance and On-demand Sentinel-1 SBAS Services on the Geohazards Exploitation Platforms

    Science.gov (United States)

    Casu, F.; de Luca, C.; Zinno, I.; Manunta, M.; Lanari, R.

    2017-12-01

    The Geohazards Exploitation Platform (GEP) is an ESA R&D activity of the EO ground segment to demonstrate the benefit of new technologies for large scale processing of EO data. GEP aims at providing on-demand processing services for specific user needs, as well as systematic processing services to address the need of the geohazards community for common information layers and, finally, to integrate newly developed processors for scientists and other expert users. In this context, a crucial role is played by the recently launched Sentinel-1 (S1) constellation that, with its global acquisition policy, has flooded the scientific community with a huge amount of data acquired over large part of the Earth on a regular basis (down to 6-days with both Sentinel-1A and 1B passes). The Sentinel-1 data, as part of the European Copernicus program, are openly and freely accessible, thus fostering their use for the development of automated and systematic tools for Earth surface monitoring. In particular, due to their specific SAR Interferometry (InSAR) design, Sentinel-1 satellites can be exploited to build up operational services for the easy and rapid generation of advanced InSAR products useful for risk management and natural hazard monitoring. In this work we present the activities carried out for the development, integration, and deployment of two SBAS Sentinel-1 services of CNR-IREA within the GEP framework, namely the Surveillance and On-demand services. The Surveillance service consists on the systematic and automatic processing of Sentinel-1 data over selected Areas of Interest (AoI) to generate updated surface displacement time series via the SBAS-InSAR algorithm. We built up a system that is automatically triggered by every new Sentinel-1 acquisition over the AoI, once it is available on the S1 catalogue. Then, the system processes the new acquisitions only, thus saving storage space and computing time. The processing, which relies on the Parallel version of the SBAS (P

  10. Analytical model of stress field in submerged arc welding butt joint with thorough penetration

    Directory of Open Access Journals (Sweden)

    Winczek Jerzy

    2018-01-01

    Full Text Available Analytical model of temporary and residual stresses for butt welding with thorough penetration was described assuming planar section hypothesis and using integral equations of stress equilibrium of the bar and simple Hooke’s law. In solution the effect of phase transformations (structure changes and structural strains has been taken into account. Phase transformations during heating are limited by temperature values at the beginning and at the end of austenitic transformation, depending on chemical composition of steel while the progress of phase transformations during cooling is determined on the basis of TTT-welding diagram. Temperature values at the beginning and at the end of transformation are conditioned by the speed of heating. Kinetics of diffusional transformation is described basing on Johnson-Mehl-Avrami-Kolmogorov equation, while martensitic transformation, basing on Koistinen-Marburger equation. Stresses in elasto-plastic state are determined by iteration, using elastic solutions method with changeable longitudinal modulus of elasticity, conditioned by stress-strain curve. Computations of stress field have been conducted for one-side butt welded of two steel flats made from S235 steel. It has enabled a clear interpretation of influence of temperature field and phase transformation on stresses caused by welding using Submerged Arc Welding (SAW method.

  11. A novel weld seam detection method for space weld seam of narrow butt joint in laser welding

    Science.gov (United States)

    Shao, Wen Jun; Huang, Yu; Zhang, Yong

    2018-02-01

    Structured light measurement is widely used for weld seam detection owing to its high measurement precision and robust. However, there is nearly no geometrical deformation of the stripe projected onto weld face, whose seam width is less than 0.1 mm and without misalignment. So, it's very difficult to ensure an exact retrieval of the seam feature. This issue is raised as laser welding for butt joint of thin metal plate is widely applied. Moreover, measurement for the seam width, seam center and the normal vector of the weld face at the same time during welding process is of great importance to the welding quality but rarely reported. Consequently, a seam measurement method based on vision sensor for space weld seam of narrow butt joint is proposed in this article. Three laser stripes with different wave length are project on the weldment, in which two red laser stripes are designed and used to measure the three dimensional profile of the weld face by the principle of optical triangulation, and the third green laser stripe is used as light source to measure the edge and the centerline of the seam by the principle of passive vision sensor. The corresponding image process algorithm is proposed to extract the centerline of the red laser stripes as well as the seam feature. All these three laser stripes are captured and processed in a single image so that the three dimensional position of the space weld seam can be obtained simultaneously. Finally, the result of experiment reveals that the proposed method can meet the precision demand of space narrow butt joint.

  12. Monogenetic volcanoes fed by interconnected dikes and sills in the Hopi Buttes volcanic field, Navajo Nation, USA

    Science.gov (United States)

    Muirhead, James D.; Van Eaton, Alexa R.; Re, Giuseppe; White, James D. L.; Ort, Michael H.

    2016-01-01

    Although monogenetic volcanic fields pose hazards to major cities worldwide, their shallow magma feeders (networks. Analysis of vent alignments using the pyroclastic massifs and other eruptive centers (e.g., maar-diatremes) shows a NW-SE trend, parallel to that of dikes in the region. We therefore infer that dikes fed many of the eruptions. Dikes are also observed in places transforming to transgressive (ramping) sills. Estimates of the observable volume of dikes (maximum volume of 1.90 × 106 m3) and sills (minimum volume of 8.47 × 105 m3) in this study reveal that sills at Hopi Buttes make up at least 30 % of the shallow intruded volume (∼2.75 × 106 m3 total) within 350 m of the paeosurface. We have also identified saucer-shaped sills, which are not traditionally associated with monogenetic volcanic fields. Our study demonstrates that shallow feeders in monogenetic fields can form geometrically complex networks, particularly those intruding poorly consolidated sedimentary rocks. We conclude that the Hopi Buttes eruptions were primarily fed by NW-SE-striking dikes. However, saucer-shaped sills also played an important role in modulating eruptions by transporting magma toward and away from eruptive conduits. Sill development could have been accompanied by surface uplifts on the order of decimeters. We infer that the characteristic feeder systems described here for the Hopi Buttes may underlie monogenetic fields elsewhere, particularly where magma intersects shallow, and often weak, sedimentary rocks. Results from this study support growing evidence of the important role of shallow sills in active monogenetic fields.

  13. Microstructure feature of friction stir butt-welded ferritic ductile iron

    International Nuclear Information System (INIS)

    Chang, Hung-Tu; Wang, Chaur-Jeng; Cheng, Chin-Pao

    2014-01-01

    Highlights: • Defect-free ferritic ductile iron joints is fabricated by FSW. • The welding nugget is composed of graphite, martensite, and recrystallized ferrite. • The graphite displays a striped pattern in the surface and advancing side. • The ferritic matrix transforms into martensite structure during welding. • High degree of plastic deformation is found on the advancing side. - Abstract: This study conducted friction stir welding (FSW) by using the butt welding process to join ferritic ductile iron plates and investigated the variations of microsturcture in the joined region formed after welding. No defects appeared in the resulting experimental weld, which was formed using a 3-mm thick ductile iron plate and tungsten carbide alloy stir rod to conduct FSW at a rotational speed of 982 rpm and traveling speed of 72 mm/min. The welding region was composed of deformed graphite, martensite phase, and dynamically recrystallized ferrite structures. In the surface region and on the advancing side (AS), the graphite displayed a striped configuration and the ferritic matrix transformed into martensite. On the retreating side (RS), the graphite surrounded by martensite remained as individual granules and the matrix primarily comprised dynamically recrystallized ferrite. After welding, diffusion increased the carbon content of the austenite around the deformed graphite nodules, which transformed into martensite during the subsequent cooling process. A micro Vickers hardness test showed that the maximum hardness value of the martensite structures in the weld was approximately 800 HV. An analysis using an electron probe X-ray microanalyzer (EPMA) indicated that its carbon content was approximately 0.7–1.4%. The peak temperature on the RS, 8 mm from the center of the weld, measured 630 °C by the thermocouple. Overall, increased severity of plastic deformation and process temperature near the upper stir zone (SZ) resulted in distinct phase transformation

  14. Enhancements to the Sentinel Fireball Network Video Software

    Science.gov (United States)

    Watson, Wayne

    2009-05-01

    The Sentinel Fireball Network that supports meteor imaging of bright meteors (fireballs) has been in existence for over ten years. Nearly five years ago it moved from gathering meteor data with a camera and VCR video tape to a fisheye lens attached to a hardware device, the Sentinel box, which allowed meteor data to be recorded on a PC operating under real-time Linux. In 2006, that software, sentuser, was made available on Apple, Linux, and Window operating systems using the Python computer language. It provides basic video and management functionality and a small amount of analytic software capability. This paper describes the new and attractive future features of the software, and, additionally, it reviews some of the research and networks from the past and present using video equipment to collect and analyze fireball data that have applicability to sentuser.

  15. Ex vivo sentinel lymph node investigation in colorectal cancer

    Directory of Open Access Journals (Sweden)

    Antônio Hilário Alves Freitas

    2013-01-01

    Full Text Available Introduction: In Brazil, about 26,000 cases of colorectal cancer are diagnosed per year. Pa- tients considered at the early stage of disease (without lymph node evolve with tumor relapse or recurrence in up to a quarter of cases, probably due to understaging. Objective: Research on ex vivo sentinel lymph node in patients with colorectal adenocarcinoma. Materials and methods: We studied 37 patients who underwent curative surgical resection. The marker used to identify lymph nodes was patent blue dye injected into the peritu- moral submucosa of the open surgical specimen immediately after its removal from the abdominal cavity. Results: Ex vivo identification of sentinel lymph node with marker occurred in 13 (35.1% patients. The sensitivity was 40% and 60% false negative. The detailed histological examina- tion of sentinel lymph nodes with multilevel section and immunohistochemistry showed metastasis in one (4.3% individual, considered ultra-staging. Conclusion: The ex vivo identification of sentinel lymph node had questionable benefits, and worse results when include patients with rectal cancer. Restaging of one patient was possible after multilevel section and immunohistochemistry of the sentinel lymph node, but more research is needed to evaluate the role of micrometastases in patients with colorectal cancer. Resumo: Introdução: No Brasil, a cada ano são diagnosticados cerca de 26.000 casos de câncer colorre- tal. Pacientes com estadiamento considerado inicial, sem linfonodo metastático, evoluem com recorrência ou recidiva do tumor em até um quarto dos casos, por provável subesta- diamento. Objetivo: pesquisar sobre linfonodo-sentinela ex vivo em pacientes com adeno- carcinoma colorretal. Objetivo: Foram estudados 37 pacientes, submetidos à cirurgia oncológica com ressecção caráter curativo. O marcador de linfonodos utilizado foi o corante azul patente, injetado na submucosa peritumoral da peça cirúrgica aberta imediatamente

  16. TIG-dressing of High Strength Steel Butt Welded Connections. Part 1 : Weld Toe Geometry and Local Hardness

    NARCIS (Netherlands)

    Van Es, S.H.J.; Kolstein, M.H.; Pijpers, R.J.M.; Bijlaard, F.S.K.

    2014-01-01

    This paper presents the results of extensive measurements on weld toe geometry of as-welded and TIG-dressed butt welded connections in high strength steels S460, S690 and very high strength steels S890 and S1100. Descriptions of the measurement techniques and data analysis are presented. Four weld

  17. TIG-dressing of high strength steel butt welded connections - Part 1: weld toe geometry and local hardness

    NARCIS (Netherlands)

    Es, S.H.J. van; Kolstein, M.H.; Pijpers, R.J.M.; Bijlaard, F.S.K.

    2013-01-01

    This paper presents the results of extensive measurements on weld toe geometry of as-welded and TIG-dressed butt welded connections in high strength steels S460, S690 and very high strength steels S890 and S1100. Descriptions of the measurement techniques and data analysis are presented. Four weld

  18. Role of the technologist in the lymphoscintigraphy and the identification of sentinel node in malignant skin melanoma

    International Nuclear Information System (INIS)

    Barbier, D.

    2002-01-01

    The biopsy of the first tumor-draining lymph node (sentinel node) is bound to become the procedure of choice in regional staging of skin melanoma patients. In our department, we do successively: lymphoscintigraphy; identification of sentinel node by γ probe before surgery; identification during surgery of sentinel node with γ probe. During those different steps, the technologist has an important role. The different steps of the technologist's work are: Preparation of radiopharmaceutical Tc 99m Nanocolloides (Nanocis Cis Bio Int); Control of radio chemical purity(RCP) by thin-layer chromatography (TLC); Programming of acquisition protocol on the γ camera; Acquisition of dynamic and static images; Identification percutaneous of the sentinel node with the γ probe and Co 57 pencil; Processing of scintigraphic images; At least identification with surgeon of the sentinel node. After excision of the lymph node, we have to verify the disappearing of radioactivity. Those steps will be illustrated by different clinical cases. Conclusion: Sentinel node identification is: New useful technique for patient: not very much invasive; screening of patients with high risk factors; great parameters of prognosis; Interest for technologist: narrow collaboration with nuclearist and surgeon; psychological role close to the patient; various competency of technologist; diagnostic and therapeutic participations

  19. Mulig forbedret behandling af kolorektal cancer med sentinel lymph node-diagnostik

    DEFF Research Database (Denmark)

    Burgdorf, Stefan Kobbelgaard; Eriksen, Jens Ravn; Gögenur, Ismail

    2014-01-01

    Possibly improved treatment of colorectal cancer by sentinel lymph node mapping Prognosis for colorectal cancer is dependent on radical surgical intervention. Chemotherapy in patients with advanced disease has improved the survival. A considerable proportion of the patients going through radical...... surgery will subsequently relapse. Adjuvant chemotherapy is reserved for patients with lymph node metastases, why undetected malignant lymph nodes will result in understaging and exclusion from the possible benefit of adjuvant chemotherapy. With sentinel lymph node mapping it may be possible to detect...... and resect more malignant lymph node and maybe even avoid extensive resections....

  20. Results from the radiometric validation of Sentinel-3 optical sensors using natural targets

    Science.gov (United States)

    Fougnie, Bertrand; Desjardins, Camille; Besson, Bruno; Bruniquel, Véronique; Meskini, Naceur; Nieke, Jens; Bouvet, Marc

    2016-09-01

    The recently launched SENTINEL-3 mission measures sea surface topography, sea/land surface temperature, and ocean/land surface colour with high accuracy. The mission provides data continuity with the ENVISAT mission through acquisitions by multiple sensing instruments. Two of them, OLCI (Ocean and Land Colour Imager) and SLSTR (Sea and Land Surface Temperature Radiometer) are optical sensors designed to provide continuity with Envisat's MERIS and AATSR instruments. During the commissioning, in-orbit calibration and validation activities are conducted. Instruments are in-flight calibrated and characterized primarily using on-board devices which include diffusers and black body. Afterward, vicarious calibration methods are used in order to validate the OLCI and SLSTR radiometry for the reflective bands. The calibration can be checked over dedicated natural targets such as Rayleigh scattering, sunglint, desert sites, Antarctica, and tentatively deep convective clouds. Tools have been developed and/or adapted (S3ETRAC, MUSCLE) to extract and process Sentinel-3 data. Based on these matchups, it is possible to provide an accurate checking of many radiometric aspects such as the absolute and interband calibrations, the trending correction, the calibration consistency within the field-of-view, and more generally this will provide an evaluation of the radiometric consistency for various type of targets. Another important aspect will be the checking of cross-calibration between many other instruments such as MERIS and AATSR (bridge between ENVISAT and Sentinel-3), MODIS (bridge to the GSICS radiometric standard), as well as Sentinel-2 (bridge between Sentinel missions). The early results, based on the available OLCI and SLSTR data, will be presented and discussed.

  1. Control of Precambrian basement deformation zones on emplacement of the Laramide Boulder batholith and Butte mining district, Montana, United States

    Science.gov (United States)

    Berger, Byron R.; Hildenbrand, Thomas G.; O'Neill, J. Michael

    2011-01-01

    What are the roles of deep Precambrian basement deformation zones in the localization of subsequent shallow-crustal deformation zones and magmas? The Paleoproterozoic Great Falls tectonic zone and its included Boulder batholith (Montana, United States) provide an opportunity to examine the importance of inherited deformation fabrics in batholith emplacement and the localization of magmatic-hydrothermal mineral deposits. Northeast-trending deformation fabrics predominate in the Great Falls tectonic zone, which formed during the suturing of Paleoproterozoic and Archean cratonic masses approximately 1,800 mega-annum (Ma). Subsequent Mesoproterozoic to Neoproterozoic deformation fabrics trend northwest. Following Paleozoic through Early Cretaceous sedimentation, a Late Cretaceous fold-and-thrust belt with associated strike-slip faulting developed across the region, wherein some Proterozoic faults localized thrust faulting, while others were reactivated as strike-slip faults. The 81- to 76-Ma Boulder batholith was emplaced along the reactivated central Paleoproterozoic suture in the Great Falls tectonic zone. Early-stage Boulder batholith plutons were emplaced concurrent with east-directed thrust faulting and localized primarily by northwest-trending strike-slip and related faults. The late-stage Butte Quartz Monzonite pluton was localized in a northeast-trending pull-apart structure that formed behind the active thrust front and is axially symmetric across the underlying northeast-striking Paleoproterozoic fault zone, interpreted as a crustal suture. The modeling of potential-field geophysical data indicates that pull-apart?stage magmas fed into the structure through two funnel-shaped zones beneath the batholith. Renewed magmatic activity in the southern feeder from 66 to 64 Ma led to the formation of two small porphyry-style copper-molybdenum deposits and ensuing world-class polymetallic copper- and silver-bearing veins in the Butte mining district. Vein orientations

  2. SENTINEL trademark technical basis report for Peach Bottom. Final report

    International Nuclear Information System (INIS)

    1998-04-01

    PECO Energy in cooperation with the Electric Power Research Institute (EPRI) installed the SENTINEL trademark software at its Peach Bottom Atomic Power Station (PBAPS). This software incorporates models of the safety and support systems which are used to display the defense in depth present in the plant and a quantitative assessment of the plant risks during proposed on-line maintenance. During the past nine months, PECO Energy personnel have used this display to evaluate the safety of proposed on-line maintenance schedules. The report describes the motivation for and the development of the SENTINEL software. It describes the generation of Safety Function Assessment Trees and Plant Transient Assessment Trees and their use in evaluating the level of defense-in-depth of key plant safety functions and the susceptibility of the plant to critical transient events. Their results are displayed by color indicators ranging from green, through yellow and orange, to red to show increasingly hazardous conditions. The report describes the use of the PBAPS Probabilistic Safety Assessment within the SENTINEL code to calculate an instantaneous core damage frequency and the criteria by which this frequency is translated to a color indicator

  3. Comparison of Landsat-8 and Sentinel-2A reflectance and normalized difference vegetation index

    Science.gov (United States)

    Zhang, H.; Roy, D. P.; Yan, L.; Li, Z.; Huang, H.

    2017-12-01

    The moderate spatial resolution satellite data from the polar-orbiting Landsat-8 (launched 2013) and Sentinel-2A (launched 2015) sensors provide 10 m to 30 m multi-spectral global coverage with a better than 5-day revisit. Although a national laboratory traceable cross-calibration comparison of the Landsat-8 Operational Land Imager (OLI) and the Sentinel-2A MultiSpectral Instrument (MSI) was undertaken pre-launch, there are a number of other sensor differences, notably due to spectral, spatial and angular differences. To examine these in a comprehensive way, Landsat-8 and Sentinel-2A data for approximately 20° × 10° of southern Africa acquired in the summer (January to March) and winter (July to September) of 2016 were compared. Only Landsat-8 and Sentinel-2A observations acquired within one-day apart were considered. The sensor data were registered and then each orbit projected into 30 m fixed global Web Enabled Landsat Data (GWELD) tiles defined in the MODIS sinusoidal equal area projection. Only corresponding sensor observations of each 30 m tile pixel that were flagged as cloud and snow-free, unsaturated, and that had no significant change in their one day separation, were compared. Both the Landsat-8 and Sentinel-2A data were atmospherically corrected using the Landsat Surface Reflectance Code (LaSRC) and were also corrected to nadir BRDF adjusted reflectance (NBAR). Top of atmosphere and surface reflectance for the spectrally corresponding visible, near infrared and shortwave infrared OLI and MSI bands, and derived normalized difference vegetation index (NDVI), were compared and their differences quantified using regression analyses. The resulting statistical transformations may be used to improve the consistency between the Landsat-8 OLI and Sentinel-2A MSI data. The importance and sensitivity of the results to correct filtering, atmospheric correction and adjustment to NBAR is demonstrated.

  4. Is the HIV sentinel surveillance system adequate in China? Findings from an evaluation of the national HIV sentinel surveillance system

    Directory of Open Access Journals (Sweden)

    Marc Bulterys

    2012-11-01

    Full Text Available Background: An external evaluation was conducted to assess the performance of the national HIV sentinel surveillance system (HSS, identify operational challenges at national and local levels and provide recommendations for improvement.Methods: The United States Centers for Disease Control and Prevention’s (CDC Updated Guidelines for Evaluating Public Health Surveillance Systems were followed to assess the key attributes of HSS. Comprehensive assessment activities were conducted, including: using a detailed checklist to review surveillance guidelines, protocols and relevant documents; conducting self-administered, anonymous surveys with 286 local China CDC staff; and carrying out field observations in 32 sentinel sites in four provinces.Results: China has built an extensive HSS with 1888 sentinel sites to monitor HIV epidemic trends by population groups over time. The strengths of HSS lie in its flexibility, simplicity, usefulness and increase in coverage in locations and populations. With its rapid expansion in 2010, HSS faces challenges in maintaining acceptability, timeliness, data quality, representativeness and sustainability.Recommendations: Implementation of the national guidelines should be standardized by strengthening training, monitoring and supervision of all staff involved, including community-based organizations. National surveillance guidelines need to be revised to strengthen data quality and representativeness, particularly to include specific instructions on HIV testing result provision, collection of identifying information, sample size and sampling methods particularly for men who have sex with men (MSM, collection of refusal information, and data interpretation. Sustainability of China’s HSS could be strengthened by applying locally tailored surveillance strategies, strengthening coordination and cooperation among government agencies and ensuring financial and human resources.

  5. A Harmonized Landsat-Sentinel-2 Surface Reflectance product: a resource for Agricultural Monitoring

    Science.gov (United States)

    Masek, J. G.; Claverie, M.; Ju, J.; Vermote, E.; Justice, C. O.

    2015-12-01

    The combination of Landsat and Sentinel-2 data offers a unique opportunity to observe globally the land every 2-3 days at medium (reflectance data from Landsat and Sentinel-2 missions and to deliver them to the community in a combined, seamless form. The HLS will be beneficial for global agricultural monitoring applications that require medium spatial resolution and weekly or more frequent observations. In particular, the provided opportunity to track crop phenology at the scale of individual fields will support detailed mapping of crop type and type-specific vegetation conditions. To create a compatible set of radiometric measurements, the HLS product relies on rigorous pre- and post-launch cross-calibration (Landsat-8 OLI and Sentinel-2 MSI) activities. The processing chain includes the following components: atmospheric correction, cloud/shadow masking, nadir BRDF-adjustment, spectral-adjustment, regridding, and temporal composite. The atmospheric correction and cloud masking is based on the OLI atmospheric correction developed at NASA-GSFC and has been adapted to the MSI data. The BRDF-adjustment is based on a disaggregation technique using MODIS-based BRDF coefficients. The technique has been evaluated using the multi-angular acquisition from the SPOT 4 and 5 (Take5) experiments. The spectral-adjustment relies on a linear regression that has been calibrated and evaluated using synthetic data and surface reflectance processed from a large number of hyperspectral EO-1 Hyperion scenes. Finally, significant effort is placed on product validation and evaluation. The delivered data set will include surface reflectance products at different levels: Using the native gridding, i.e. UTM, 30m for Landsat-8, and UTM, 10-20m for Sentinel-2 Using a common global gridding (Sinusoidal, 30m) Temporal composite (Sinusoidal, 30m, 5-day) During the first year of operation of Sentinel-2A, the HLS will be prototyped over a selection of 30 sites that includes some of the JECAM sites

  6. Temporary shielding of hot spots in the drainage areas of cutaneous melanoma improves accuracy of lymphoscintigraphic sentinel lymph node diagnostics

    International Nuclear Information System (INIS)

    Maza, S.; Valencia, R.; Geworski, L.; Zander, A.; Munz, D.L.; Draeger, E.; Winter, H.; Sterry, W.

    2002-01-01

    Detection of the ''true'' sentinel lymph nodes, permitting correct staging of regional lymph nodes, is essential for management and prognostic assessment in malignant melanoma. In this study, it was prospectively evaluated whether simple temporary shielding of hot spots in lymphatic drainage areas could improve the accuracy of sentinel lymph node diagnostics. In 100 consecutive malignant melanoma patients (45 women, 55 men; age 11-91 years), dynamic and static lymphoscintigraphy in various views was performed after strict intracutaneous application of technetium-99m nanocolloid (40-150 MBq; 0.05 ml/deposit) around the tumour (31 patients) or the biopsy scar (69 patients, safety distance 1 cm). The images were acquired with and without temporary lead shielding of the most prominent hot spots in the drainage area. In 33/100 patients, one or two additional sentinel lymph nodes that showed less tracer accumulation or were smaller (<1.5 cm) were detected after shielding. Four of these patients had metastases in the sentinel lymph nodes; the non-sentinel lymph nodes were tumour negative. In 3/100 patients, hot spots in the drainage area proved to be lymph vessels, lymph vessel intersections or lymph vessel ectasias after temporary shielding; hence, a node interpreted as a non-sentinel lymph node at first glance proved to be the real sentinel lymph node. In two of these patients, lymph node metastasis was histologically confirmed; the non-sentinel lymph nodes were tumour free. In 7/100 patients the exact course of lymph vessels could be mapped after shielding. In one of these patients, two additional sentinel lymph nodes (with metastasis) were detected. Overall, in 43/100 patients the temporary shielding yielded additional information, with sentinel lymph node metastases in 7%. In conclusion, when used in combination with dynamic acquisition in various views, temporary shielding of prominent hot spots in the drainage area of a malignant melanoma of the skin leads to an

  7. Quality of Pinus elliottii sawn timber from tapped forests

    Directory of Open Access Journals (Sweden)

    Pedro Henrique Gonzalez de Cademartori

    2012-12-01

    Full Text Available This study aimed to characterize the quality of Pinus elliottii sawn timber extracted from tapped forests and processed in a sawmill in São José do Norte (RS. Four butt logs and four upper logs for each of the three existing diameter grades were selected and sawed. The wood pieces were analyzed after sawing and after kiln drying. The presence of knots, which occurred due to the absence of forest management and influenced the qualitative classification of the wood pieces, was observed mainly in the samples from upper logs. The process of resin tapping contributed to a higher incidence of resin pockets in the samples from butt logs, also influencing the qualitative classification of the samples. The appearance of drying defects did not modify the classification of the wood samples from butt and upper logs.

  8. Application of ultrasonic NDT technique for butt fusion joints of plastic pipes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Gyung; Lim, Hyung Taik; Choi, Jeong Guen; Lee, Jae Myung [ANSCO, Daejeon (Korea, Republic of)

    2016-05-15

    The long term-durability and the soundness of the plastic pipe have been sufficiently verified through use of the plastic pipe during the past several decades. Recently, as the pipe material have been constantly developed, the application of the plastic pipe is expanded to various industrial fields, such as an increase of a use pressure, the bigger diameter of the pipe, etc. In a nuclear power plant where a carbon steel pipe and a stainless steel pipe are mainly used as a safety class III buried pipe, safety in an operation is seriously threatened by abrasion, heat deterioration or the like, frequently generated in a metal pipe. Therefore, in order to provide an alternate to this problem there is a rising interest on using high-density polyethylene (HDPE) pipes which are known to provide much enhanced corrosion, abrasion and impact resistant properties. With polyethylene piping, one of the issue that is being looked into is the integrity of butt-fusion joint. At the present time the Referencing Code and Standard for the NDT technology of for butt fusion joint of the plastic pipe have not yet established. An optimum inspection parameters were determined according to the thickness of the HDPE pipe. It was also confirmed that most of the detection results of two techniques have matched with each other. In the PAUT, it is easy to distinguish signals with from the flaws made by the thin plate and the void. Also the resolving power of PAUT on the detection in the depth direction has been demonstrated to be satisfactory.

  9. History, present status and future of sentinel node biopsy in breast cancer. The Mary Béves Lecture.

    Science.gov (United States)

    Mansel, R E; Khonji, N I; Clarke, D

    2000-01-01

    The word Sentinel' is defined in The Oxford English Dictionary as 'a guard, one who keeps watch or a sentry'. When translated to the concept of a tumour and its lymph node drainage, the sentinel node could be interpreted to mean the lymph node that guards or keeps watch over a tumour. The sentinel lymph node can thus be defined as the first lymph node that drains a primary tumour within the regional lymphatic basin of that tumour. We know that tumour progression in breast cancer often occurs in an orderly, progressive fashion. So in theory, if the sentinel node is tumour free then the rest of the nodes in the lymphatic basin should also be uninvolved by the tumour.

  10. [Sentinel node in melanoma and breast cancer. Current considerations].

    Science.gov (United States)

    Vidal-Sicart, S; Vilalta Solsona, A; Alonso Vargas, M I

    2015-01-01

    The main objectives of sentinel node (SN) biopsy is to avoid unnecessary lymphadenectomies and to identify the 20-25% of patients with occult regional metastatic involvement. This technique reduces the associated morbidity from lymphadenectomy and increases the occult lymphatic metastases identification rate by offering the pathologist the or those lymph nodes with the highest probability of containing metastatic cells. Pre-surgical lymphoscintigraphy is considered a "road map" to guide the surgeon towards the sentinel nodes and to localize unpredictable lymphatic drainage patterns. The SPECT/CT advantages include a better SN detection rate than planar images, the ability to detect SNs in difficult to interpret studies, better SN depiction, especially in sites closer to the injection site and better anatomic localization. These advantages may result in a change in the patient's clinical management both in melanoma and breast cancer. The correct SN evaluation by pathology implies a tumoral load stratification and further prognostic implication. The use of intraoperative imaging devices allows the surgeon a better surgical approach and precise SN localization. Several studies reports the added value of such devices for more sentinel nodes excision and a complete monitoring of the whole procedure. New techniques, by using fluorescent or hybrid tracers, are currently being developed. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  11. Geology of the Pumpkin Buttes Area of the Powder River Basin, Campbell and Johnson Counties, Wyoming

    Science.gov (United States)

    Sharp, William Neil; White, Amos McNairy

    1956-01-01

    About 200 uranium occurrences have been examined in the Pumpkin Buttes area, Wyoming. Uranium minerals are visible at most of these places and occur in red and buff sandstone lenses in the Wasatch formation of Eocene age. The uranium minerals are disseminated in buff sandstone near red sandstone, and also occur in red sandstone in manganese oxide concretions and uraninite concretions.

  12. Value of sonomammography utilizing color Doppler technique in qualification of breast cancer patients for sentinel node identification

    International Nuclear Information System (INIS)

    Basta, P.; Wadowska-Jaszczynska, K.; Krysztopowicz, W.; Przybylska, P.; Wisniowski, Z.

    2007-01-01

    Sentinel node identification has become a standard procedure in the management of breast cancer. This procedure requires involvement of a multidisciplinary team and is rather costly. Ultrasonography (USG) of axillary lymph nodes is a method that gives hope for improving the quality of qualification of patients for the procedure. Eighty patients with grade I and II breast cancers underwent sentinel node identification followed by axillary lymphadenectomy. Pre-operative ultrasonography was employed to assess axillary lymph nodes, using the morphological and vascular characteristics as predictors of the presence of lymph node metastases. Sensitivity of sentinel node identification reached 89.3%, specificity - 100%, positive predictive value - 100%, negative predictive value - 93.5%, percentage of false negative results - 10.7%. Sensitivity of USG reached 68.75 %, and specificity - 70.31%. In the group of patients in whom the sentinel node was identified, the sensitivity of the method was 69.23 %, and specificity - 72.41%. Preoperative axillary lymph node ultrasonography in breast cancer patients, utilizing color Doppler technique, allows better selection of patients for sentinel node identification procedure. (author)

  13. Butt-joint integration of active optical components based on InP/AlInGaAsP alloys

    DEFF Research Database (Denmark)

    Kulkova, Irina; Kuznetsova, Nadezda; Semenova, Elizaveta

    2014-01-01

    We demonstrate all-active planar high quality butt-joint (BJ) integration of a QW Semiconductor Optical Amplifier (SOA) and MQW Electro-Absorption Modulator (EAM) based on an InP/AlInGaAsP platform. The degradation of the optical properties in the vicinity of ~1 μm to the BJ interface was determi...

  14. 2014-2016 Mt. Etna Ground deformation imaged by SISTEM approach using GPS and SENTINEL-1A/1B TOPSAR data

    Science.gov (United States)

    Bonforte, Alessandro; Guglielmino, Francesco; Puglisi, Giuseppe

    2017-04-01

    In the frame of the EC FP7 MED-SUV project (call FP7 ENV.2012.6.4-2), and thanks to the GEO-GSNL initiative, GPS data and SENTINEL 1A/1B TOPSAR acquired on Mt. Etna between October 2014 and November 2016 were analyzed. The SENTINEL data were used in order to combine and integrate them with GPS, and detail the ground deformation recorded by GPS on Mt. Etna, during the last two-year's volcanic activity. The Sentinel data were processed by GAMMA software, using a spectral diversity method and a procedure able to co-register the SENTINEL pairs with extremely high precision (processing, a new software architecture based on the hypervisor virtualization technology for the x64 versions of Windows has been implemented. The DInSAR results are analysed and successively used as input for the time series analysis using the StaMPS package. On December 28, 2014 eruptive activity resumed at Mt. Etna with a fire fountain activity feeding two lava flows spreading on the eastern and south-western upper flanks of the volcano, producing evident deformation at the summit of the volcano. GPS displacements and Sentinel-1A ascending interferogram were calculated in order to image the ground deformation pattern accompanying the eruption. The ground deformation pattern has been perfectly depicted by the GPS network, mainly affecting the uppermost part of the volcano edifice, with a strong decay of the deformation, according to a very shallow and strong dyke intrusion. The Sentinel 1A SAR data, covering the similar time spanning, confirmed that most of displacements are related to the dike intrusion, and evidenced a local gravity-driven motion of the western wall of the Valle del Bove, probably related to the dike intrusion. To monitor the temporal successive evolution of ground deformation, we performed an A-DInSAR SENTINEL analysis using the Small BAseline Subset (SBAS) approach included with the StaMPS processing package. The April 2015-December 2015, SBAS Time series, shown a volcano

  15. EANM practice guidelines for lymphoscintigraphy and sentinel lymph node biopsy in melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Bluemel, Christina; Herrmann, Ken; Lassmann, Michael [Universitaetsklinikum Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); Giammarile, Francesco; Dubreuil, Julien [Universite Claude Bernard Lyon 1, Medecine Nucleaire, Hospices Civils de Lyon and EA 3738, Lyon (France); Nieweg, Omgo E.; Chakera, Annette H. [The Poche Centre, Melanoma Institute Australia, North Sydney (Australia); Testori, Alessandro [European Institute of Oncology, Milan (Italy); Audisio, Riccardo A. [University of Liverpool, St Helens Teaching Hospital, St Helens (United Kingdom); Zoras, Odysseas [University Hospital of Heraklion, Department of Surgical Oncology, Heraklion (Greece); Uren, Roger [The University of Sydney, Sydney Medical School, Sydney, NSW (Australia); Alfred Nuclear Medicine and Ultrasound, RPAH Medical Centre, Newtown, NSW (Australia); Chondrogiannis, Sotirios; Rubello, Domenico [' Santa Maria della Misericordia' Hospital, Department of Nuclear Medicine, PET/CT Centre, Radiology, NeuroRadiology, Medical Physics, Rovigo (Italy); Colletti, Patrick M. [University of Southern California, Department of Radiology, Los Angeles, CA (United States)

    2015-10-15

    Sentinel lymph node biopsy is an essential staging tool in patients with clinically localized melanoma. The harvesting of a sentinel lymph node entails a sequence of procedures with participation of specialists in nuclear medicine, radiology, surgery and pathology. The aim of this document is to provide guidelines for nuclear medicine physicians performing lymphoscintigraphy for sentinel lymph node detection in patients with melanoma. These practice guidelines were written and have been approved by the European Association of Nuclear Medicine (EANM) to promote high-quality lymphoscintigraphy. The final result has been discussed by distinguished experts from the EANM Oncology Committee, national nuclear medicine societies, the European Society of Surgical Oncology (ESSO) and the European Association for Research and Treatment of Cancer (EORTC) melanoma group. The document has been endorsed by the Society of Nuclear Medicine and Molecular Imaging (SNMMI). The present practice guidelines will help nuclear medicine practitioners play their essential role in providing high-quality lymphatic mapping for the care of melanoma patients. (orig.)

  16. 76 FR 21331 - Certain Carbon Steel Butt-Weld Pipe Fittings From Brazil, Japan, Taiwan, Thailand, and the People...

    Science.gov (United States)

    2011-04-15

    ... the People's Republic of China: Continuation of Antidumping Duty Orders AGENCY: Import Administration... butt-weld pipe fittings from Brazil, Japan, Taiwan, Thailand, and the People's Republic of China (PRC), pursuant to section 751(c) of the Tariff Act of 1930, as amended (the Act). See Initiation of Five-Year...

  17. Approaching target: A service for nationwide deformation monitoring in Denmark using Sentinel-1

    DEFF Research Database (Denmark)

    Fredenslund Levinsen, Joanna; Sørensen, Carlo Sass; Broge, Niels Henrik

    processes in both the public and private sectors. This will inevitably lead to significant economic savings. The test study makes up part of the foundation for establishing a nationwide service. As such, the results over the test sites will be presented to a broad range of end-users to identify their needs...... tailored to specific needs, which increases the probability of its implementation in both the public and private sectors. Presenting the results obtained on the road to setting up a nationwide deformation monitoring will clearly demonstrate the potentials arising with the continuous stream of Sentinel-1......Building upon decades of experience with deformation monitoring from repeated precision leveling and GNSS measurements as well as more recent time series analyses of ERS, Envisat, and Sentinel-1 imagery, we are now working towards a nationwide mapping using Sentinel-1 Interferometric Wide Swath...

  18. A critical assessment on the role of sentinel node mapping in endometrial cancer.

    Science.gov (United States)

    Bogani, Giorgio; Ditto, Antonino; Martinelli, Fabio; Signorelli, Mauro; Perotto, Stefania; Lorusso, Domenica; Raspagliesi, Francesco

    2015-10-01

    Endometrial cancer is the most common gynecologic malignancy in the developed countries. Although the high incidence of this occurrence no consensus, about the role of retroperitoneal staging, still exists. Growing evidence support the safety and efficacy of sentinel lymph node mapping. This technique is emerging as a new standard for endometrial cancer staging procedures. In the present paper, we discuss the role of sentinel lymph node mapping in endometrial cancer, highlighting the most controversies features.

  19. Creep failure analysis of butt welded tubes

    International Nuclear Information System (INIS)

    Browne, R.J.; Parker, J.D.; Walters, D.J.

    1981-01-01

    As part of a major research programme to investigate the influence of butt welds on the life expectancy of tubular components, a series of internal-pressure, stress-rupture tests have been carried out. Thick walled 1/2Cr 1/2Mo 1/4V tube specimens were welded with mild steel, 1Cr 1/2Mo steel, 2 1/4Cr 1Mo steel or nominally matching 1/2Cr 1/2Mo 1/4V steel to give a wide range of weld metal creep strengths relative to the parent tube. The weldments were tested at 565 0 C at two values of internal pressure, and gave failure lives of up to 44,000 hrs. Finite element techniques have been used to determine the stationary state stress distribution in the weldment which was represented by a three material model. Significant stress redistribution was indicated and these results enabled the position and orientation of cracking and the rupture life to be predicted. The theoretical and experimental results have been used to highlight the limitations of current design methods which are based on the application of the mean diameter hoop stress to the parent material stress rupture data. (author)

  20. Sentinel-3 SAR Altimetry Toolbox - Scientific Exploitation of Operational Missions (SEOM) Program Element

    Science.gov (United States)

    Benveniste, Jérôme; Lucas, Bruno; Dinardo, Salvatore

    2014-05-01

    The prime objective of the SEOM (Scientific Exploitation of Operational Missions) element is to federate, support and expand the large international research community that the ERS, ENVISAT and the Envelope programmes have build up over the last 20 years for the future European operational Earth Observation missions, the Sentinels. Sentinel-3 builds directly on a proven heritage pioneered by ERS-1, ERS-2, Envisat and CryoSat-2, with a dual-frequency (Ku and C band) advanced Synthetic Aperture Radar Altimeter (SRAL) that provides measurements at a resolution of ~300m in SAR mode along track. Sentinel-3 will provide exact measurements of sea-surface height along with accurate topography measurements over sea ice, ice sheets, rivers and lakes. The first of the Sentinel-3 series is planned for launch in early 2015. The current universal altimetry toolbox is BRAT (Basic Radar Altimetry Toolbox) which can read all previous and current altimetry mission's data, but it does not have the capabilities to read the upcoming Sentinel-3 L1 and L2 products. ESA will endeavour to develop and supply this capability to support the users of the future Sentinel-3 SAR Altimetry Mission. BRAT is a collection of tools and tutorial documents designed to facilitate the processing of radar altimetry data. This project started in 2005 from the joint efforts of ESA (European Space Agency) and CNES (Centre National d'Etudes Spatiales, the French Space Agency), and it is freely available at http://earth.esa.int/brat. The tools enable users to interact with the most common altimetry data formats, the BratGUI is the front-end for the powerful command line tools that are part of the BRAT suite. BRAT can also be used in conjunction with Matlab/IDL (via reading routines) or in C/C++/Fortran via a programming API, allowing the user to obtain desired data, bypassing the data-formatting hassle. BRAT can be used simply to visualise data quickly, or to translate the data into other formats such as net

  1. Sentinel lymph node biopsy in node-negative squamous cell carcinoma of the oral cavity and oropharynx.

    LENUS (Irish Health Repository)

    Burns, P

    2012-02-01

    OBJECTIVES: Considerable controversy exists regarding the merits of elective neck dissection in patients with early stage oral cavity and oropharyngeal squamous cell carcinoma. It is highly desirable to have a method of identifying those patients who would benefit from further treatment of the neck when they are clinically node-negative. The purpose of the present study was to examine the use of sentinel lymph node biopsy in identifying occult neck disease in a cohort of patients with node-negative oral cavity and oropharyngeal squamous cell carcinoma. DESIGN: We evaluated a total of 13 patients with oral cavity and oropharyngeal cancer who were clinically and radiologically node-negative. RESULTS: A sentinel lymph node was found in all 13 patients, revealing metastatic disease in five patients, four of whom had one or more positive sentinel lymph nodes. There was one false negative result, in which the sentinel lymph node was negative for tumour whereas histological examination of the neck dissection specimen showed occult disease. CONCLUSION: In view of these findings, we would recommend the use of sentinel lymph node biopsy in cases of oral cavity and oropharyngeal squamous cell carcinoma, in order to aid the differentiation of those patients whose necks are harbouring occult disease and who require further treatment.

  2. Sentinel-1A - Launching the first satellite and launching the operational Copernicus programme

    Science.gov (United States)

    Aschbacher, Josef; Milagro Perez, Maria Pilar

    2014-05-01

    The first Copernicus satellite, Sentinel-1A, is prepared for launch in April 2014. It will provide continuous, systematic and highly reliable radar images of the Earth. Sentinel-1B will follow around 18 months later to increase observation frequency and establish an operational system. Sentinel-1 is designed to work in a pre-programmed conflict-free operation mode ensuring the reliability required by operational services and creating a consistent long-term data archive for applications based on long time series. This mission will ensure the continuation and improvement of SAR operational services and applications addressing primarily medium- to high-resolution applications through a main mode of operation that features both a wide swath (250 km) and high geometric (5 × 20 m) and radiometric resolution, allowing imaging of global landmasses, coastal zones, sea ice, polar areas, and shipping routes at high resolution. The Sentinel-1 main operational mode (Interferometric Wide Swath) will allow to have a complete coverage of the Earth in 6 days in the operational configuration when the two Sentinel-1 spacecraft will be in orbit simultaneously. High priority areas like Europe, Canada and some shipping routes will be covered almost daily. This high global observation frequency is unprecedented and cannot be reached with any other current radar mission. Envisat, for example, which was the 'workhorse' in this domain up to April 2012, reached global coverage every 35 days. Sentinel-1 data products will be made available systematically and free of charge to all users including institutional users, the general public, scientific and commercial users. The transition of the Copernicus programme from the development to operational phase will take place at about the same time when the first Sentinel-1 satellite will be launched. During the operational phase, funding of the programme will come from the European Union Multiannual Financial Framework (MFF) for the years 2014

  3. The study on defects in aluminum 2219-T6 thick butt friction stir welds with the application of multiple non-destructive testing methods

    International Nuclear Information System (INIS)

    Li, Bo; Shen, Yifu; Hu, Weiye

    2011-01-01

    Research highlights: → Friction stir weld-defect forming mechanisms of thick butt-joints. → Relationship between weld-defects and friction stir welding process parameters. → Multiple non-destructive testing methods applied to friction stir welds. → Empirical criterion basing on mass-conservation for inner material-loss defects. → Nonlinear correlation between weld strengths and root-flaw lengths. -- Abstract: The present study focused on the relationship between primary friction stir welding process parameters and varied types of weld-defect discovered in aluminum 2219-T6 friction stir butt-welds of thick plates, meanwhile, the weld-defect forming mechanisms were investigated. Besides a series of optical metallographic examinations for friction stir butt welds, multiple non-destructive testing methods including X-ray detection, ultrasonic C-scan testing, ultrasonic phased array inspection and fluorescent penetrating fluid inspection were successfully used aiming to examine the shapes and existence locations of different weld-defects. In addition, precipitated Al 2 Cu phase coarsening particles were found around a 'kissing-bond' defect within the weld stirred nugget zone by means of scanning electron microscope and energy dispersive X-ray analysis. On the basis of volume conservation law in material plastic deformation, a simple empirical criterion for estimating the existence of inner material-loss defects was proposed. Defect-free butt joints were obtained after process optimization of friction stir welding for aluminum 2219-T6 plates in 17-20 mm thickness. Process experiments proved that besides of tool rotation speed and travel speed, more other appropriate process parameter variables played important roles at the formation of high-quality friction stir welds, such as tool-shoulder target depth, spindle tilt angle, and fixture clamping conditions on the work-pieces. Furthermore, the nonlinear correlation between weld tensile strengths and weld crack

  4. Thick melanoma: prognostic value of positive sentinel nodes

    NARCIS (Netherlands)

    Vermeeren, Lenka; van der Ent, Fred W. C.; Sastrowijoto, Prapto S. H.; Hulsewé, Karel W. E.

    2009-01-01

    BACKGROUND: Sentinel lymph node biopsy (SNB) is a widely accepted procedure used to accurately stage patients with melanoma. Its value in patients with thick melanoma (Breslow thickness >4 mm) is reason for discussion because of the generally poor prognosis of these patients. The purpose of this

  5. Knowing what we breathe: Sentinel 4: a geostationary imaging UVN spectrometer for air quality monitoring

    Science.gov (United States)

    Bazalgette Courrèges-Lacoste, G.; Sallusti, M.; Bulsa, G.; Bagnasco, G.; Gulde, S.; Kolm, M. G.; Smith, D. J.; Maurer, R.

    2017-09-01

    Sentinel-4 is an imaging UVN (UV-VIS-NIR) spectrometer, developed by Airbus DS under ESA contract in the frame of the joint EU/ESA COPERNICUS program. The mission objective is the operational monitoring of trace gas concentrations for atmospheric chemistry and climate applications - hence the motto of Sentinel-4 "Knowing what we breathe".

  6. NOAA high resolution sea surface winds data from Synthetic Aperture Radar (SAR) on the Sentinel-1 satellites

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set consists of high resolution sea surface winds data produced from Synthetic Aperture Radar (SAR) on board Sentinel-1A and Sentinel-1B satellites. This...

  7. Improving staging accuracy in colon and rectal cancer by sentinel lymph node mapping: A comparative study

    NARCIS (Netherlands)

    van der Zaag, E. S.; Buskens, C. J.; Kooij, N.; Akol, H.; Peters, H. M.; Bouma, W. H.; Bemelman, W. A.

    2009-01-01

    Aim: To compare the predictive value of sentinel lymph node (SN) mapping between patients with colon and rectal cancer. Patients and methods: An ex vivo SN procedure was performed in 100 patients with colon and 32 patients with rectal cancer. If the sentinel node was negative, immunohistochemical

  8. Outcome of Sentinel Hospital-based and CDC-based ART Service Delivery: A Prospective Open Cohort of People Living with HIV in China.

    Science.gov (United States)

    Ning, Chuanyi; Smith, Kumi M; McCann, Chase D; Hu, Fengyu; Lan, Yun; Zhang, Fuchun; Liang, Hao; Zhao, Jinmin; Tucker, Joseph D; Cai, Weiping

    2017-02-14

    The primary objective of this study was to obtain insights into the outcomes of people living with HIV who accessed services through HIV/AIDS sentinel hospital-based and ART service delivery in China. Post-hoc analyses of an open cohort from an observational database of 22 qualified HIV/AIDS sentinel hospital-based and two CDC-based drug delivery facilities (DDFs) in Guangdong Province was completed. Linkage to care, mortality and survival rates were calculated according to WHO criteria. 12,966 individuals received ART from HIV/AIDS sentinel hospitals and 1,919 from DDFs, with linkage to care rates of 80.7% and 79.9%, respectively (P > 0.05). Retention rates were 94.1% and 84.0% in sentinel hospitals and DDFs, respectively (P hospitals (P ART from the DDFs than sentinel hospitals, with an adjusted HR of 3.3 (95% CI: 2.3, 4.6). A crude HR of treatment termination in DDFs was 7.5 fold higher (95% CI: 6.3, 9.0) compared to sentinel hospitals. HIV/AIDS sentinel hospital had better retention, and substantially lower mortality compared to DDFs.

  9. Factors Predictive of Sentinel Lymph Node Involvement in Primary Breast Cancer.

    Science.gov (United States)

    Malter, Wolfram; Hellmich, Martin; Badian, Mayhar; Kirn, Verena; Mallmann, Peter; Krämer, Stefan

    2018-06-01

    Sentinel lymph node biopsy (SLNB) has replaced axillary lymph node dissection (ALND) for axillary staging in patients with early-stage breast cancer. The need for therapeutic ALND is the subject of ongoing debate especially after the publication of the ACOSOG Z0011 trial. In a retrospective trial with univariate and multivariate analyses, factors predictive of sentinel lymph node involvement should be analyzed in order to define tumor characteristics of breast cancer patients, where SLNB should not be spared to receive important indicators for adjuvant treatment decisions (e.g. thoracic wall irradiation after mastectomy with or without reconstruction). Between 2006 and 2010, 1,360 patients with primary breast cancer underwent SLNB with/without ALND with evaluation of tumor localization, multicentricity and multifocality, histological subtype, tumor size, grading, lymphovascular invasion (LVI), and estrogen receptor, progesterone receptor and human epidermal growth factor receptor 2 status. These characteristics were retrospectively analyzed in univariate and multivariate logistic regression models to define significant predictive factors for sentinel lymph node involvement. The multivariate analysis demonstrated that tumor size and LVI (pbreast cancer. Because of the increased risk for metastatic involvement of axillary sentinel nodes in cases with larger breast cancer or diagnosis of LVI, patients with these breast cancer characteristics should not be spared from SLNB in a clinically node-negative situation in order to avoid false-negative results with a high potential for wrong indication of primary breast reconstruction or wrong non-indication of necessary post-mastectomy radiation therapy. The prognostic impact of avoidance of axillary staging with SLNB is analyzed in the ongoing prospective INSEMA trial. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  10. Contraindications of sentinel lymph node biopsy: Áre there any really?

    Directory of Open Access Journals (Sweden)

    Zografos George

    2007-01-01

    Full Text Available Abstract Background One of the most exciting and talked about new surgical techniques in breast cancer surgery is the sentinel lymph node biopsy. It is an alternative procedure to standard axillary lymph node dissection, which makes possible less invasive surgery and side effects for patients with early breast cancer that wouldn't benefit further from axillary lymph node clearance. Sentinel lymph node biopsy helps to accurately evaluate the status of the axilla and the extent of disease, but also determines appropriate adjuvant treatment and long-term follow-up. However, like all surgical procedures, the sentinel lymph node biopsy is not appropriate for each and every patient. Methods In this article we review the absolute and relative contraindications of the procedure in respect to clinically positive axilla, neoadjuvant therapy, tumor size, multicentric and multifocal disease, in situ carcinoma, pregnancy, age, body-mass index, allergies to dye and/or radio colloid and prior breast and/or axillary surgery. Results Certain conditions involving host factors and tumor biologic characteristics may have a negative impact on the success rate and accuracy of the procedure. The overall fraction of patients unsuitable or with multiple risk factors that may compromise the success of the sentinel lymph node biopsy, is very small. Nevertheless, these patients need to be successfully identified, appropriately advised and cautioned, and so do the surgeons that perform the procedure. Conclusion When performed by an experienced multi-disciplinary team, the SLNB is a highly effective and accurate alternative to standard level I and II axillary clearance in the vast majority of patients with early breast cancer.

  11. Merging high resolution geophysical and geochemical surveys to reduce exploration risk at glass buttes, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Patrick [Ormat Nevada, Inc., Reno, NV (United States); Fercho, Steven [Ormat Nevada, Inc., Reno, NV (United States); Perkin, Doug [Ormat Nevada, Inc., Reno, NV (United States); Martini, Brigette [Corescan Inc., Ascot (Australia); Boshmann, Darrick [Oregon State Univ., Corvallis, OR (United States)

    2015-06-01

    The engineering and studies phase of the Glass Buttes project was aimed at reducing risk during the early stages of geothermal project development. The project’s inclusion of high resolution geophysical and geochemical surveys allowed Ormat to evaluate the value of these surveys both independently and in combination to quantify the most valuable course of action for exploration in an area where structure, permeability, and temperature are the most pressing questions. The sizes of the thermal anomalies at Glass Buttes are unusually large. Over the course of Phase I Ormat acquired high resolution LIDAR data to accurately map fault manifestations at the surface and collected detailed gravity and aeromagnetic surveys to map subsurface structural features. In addition, Ormat collected airborne hyperspectral data to assist with mapping the rock petrology and mineral alteration assemblages along Glass Buttes faults and magnetotelluric (MT) survey to try to better constrain the structures at depth. Direct and indirect identification of alteration assemblages reveal not only the geochemical character and temperature of the causative hydrothermal fluids but can also constrain areas of upflow along specific fault segments. All five datasets were merged along with subsurface lithologies and temperatures to predict the most likely locations for high permeability and hot fluids. The Glass Buttes temperature anomalies include 2 areas, totaling 60 km2 (23 mi2) of measured temperature gradients over 165° C/km (10° F/100ft). The Midnight Point temperature anomaly includes the Strat-1 well with 90°C (194 °F) at 603 m (1981 ft) with a 164 °C/km (10°F/100ft) temperature gradient at bottom hole and the GB-18 well with 71°C (160 °F) at 396 m (1300 ft) with a 182°C/km (11°F/100ft) gradient. The primary area of alteration and elevated temperature occurs near major fault intersections associated with Brothers Fault Zone and Basin and Range systems. Evidence for faulting is

  12. El sistema de yacimientos de mamíferos miocenos del Cerro de los Batallones, Cuenca de Madrid: estado actual y perspectivas

    NARCIS (Netherlands)

    Morales, J.; Pozo, M.; Silva, P.G.; Domingo, M.S.; López-Antoñanzas, R.; Álvarez Sierra, A.; Antón, M.; Martín Escorza, C.; Quiralte, V.; Salesa, M.J.; Sánchez, I.M.; Azanza, B.; Calvo, J.P.; Carrasco, P.; García-Paredes, I.; Knoll, F.; Hernández Fernández, M.; Hoek Ostende, van den L.W.; Merino, L.; Meulen, van der A.J.; Montoya, P.; Peigné, S.; Peláez-Campomanes, P.; Sánchez-Marco, A.; Turner, A.; Abella, J.; Alcalde, G.M.; Andrés, M.; DeMiguel, D.; Cantalapiedra, J.L.; Fraile, S.; García Yelo, B.A.; Gómez Cano, A.R.; López Guerrero, P.; Oliver Pérez, A.; Siliceo, G.

    2008-01-01

    The Cerro de los Batallones (Los Batallones Butte) is located in the central-northern area of the Madrid Basin, central Spain. Nine vertebrates localities containing a large variety of mammals of Upper Vallesian Age (Late Miocene) have been found associated with the sediments forming the butte. From

  13. Sentinel Lymph Node Biopsy Following Neoadjuvant Chemotherapy: Review of the Literature and Recommendations for Use in Patient Management

    Directory of Open Access Journals (Sweden)

    Yan Xing

    2004-10-01

    Full Text Available Breast cancer is a significant health problem worldwide and is one of the leading causes of cancer-related mortality in women. Preoperative chemotherapy has become the standard of care for patients with locally advanced disease and is being used more frequently in patients with early-stage breast cancer. Sentinel lymph node biopsy has shown great promise in the surgical management of breast cancer patients, but its use following preoperative chemotherapy is yet to be determined. Eleven studies have been published with respect to the accuracy of sentinel lymph node biopsy following neoadjuvant chemotherapy. Ten studies showed favourable results, with the ability to identify a sentinel lymph node in 84% to 98% of cases, and reported false negative rates ranging from 0% to 20%. The accuracy of sentinel lymph node biopsy following preoperative chemotherapy for breast cancer ranges from 88% to 100%, with higher rates when specific techniques and inclusion criteria are applied. The published literature supports the use of sentinel lymph node biopsy for assessment of the axilla in patients with clinically node-negative disease following preoperative chemotherapy.

  14. Sentinel Lymph Node Biopsy in Oral Cancer: Validation of Technique and Clinical Implications of Added Oblique Planar Lymphoscintigraphy and/or Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, J.B.; Soerensen, J.A.; Grupe, P.; Krogdahl, A. [Odense Univ. Hospital (Denmark). Depts. of Plastic and Reconstructive Surgery, Nuclear Medicine, and Pathology

    2005-10-01

    Purpose: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. Material and Methods: Forty patients (17 F and 23 M, aged 32-90) with 24 T1 and 16 T2 squamous cell carcinoma of the oral cavity. Planar lymphoscintigraphy, emission and transmission tomography were performed. Detection and excision of the sentinel nodes were guided by a gamma probe. The sentinel nodes were step-sectioning and stained with hematoxylin and eosin and cytokeratin (CK 1). Histology and follow-up were used as 'gold standard'. Tumor location, number of sentinel lymph nodes, metastasis, and recurrences were registered. Two observers evaluated the lymphoscintigraphic images to assess the inter-rater agreement. Results: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis ( P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel lymph node biopsy. Three patients developed a lymph node recurrence close to the primary tumor site during follow-up. Added oblique lymphoscintigraphic images and/or tomography revealed extra hotspots in 15/40 (38%) patients. In 4/40 (10%), extra contralateral hotspots were detected. Conclusion: Sentinel lymph node biopsy upstaged 28% of the patients. Sentinel lymph nodes close to the primary tumor were difficult to find. Added oblique planar images and/or tomographic images revealed extra clinical relevant hotspots in 38% of patients. Reproducibility proved excellent.

  15. Histological pattern of Merkel cell carcinoma sentinel lymph node metastasis improves stratification of Stage III patients.

    Science.gov (United States)

    Ko, Jennifer S; Prieto, Victor G; Elson, Paul J; Vilain, Ricardo E; Pulitzer, Melissa P; Scolyer, Richard A; Reynolds, Jordan P; Piliang, Melissa P; Ernstoff, Marc S; Gastman, Brian R; Billings, Steven D

    2016-02-01

    Sentinel lymph node biopsy is used to stage Merkel cell carcinoma, but its prognostic value has been questioned. Furthermore, predictors of outcome in sentinel lymph node positive Merkel cell carcinoma patients are poorly defined. In breast carcinoma, isolated immunohistochemically positive tumor cells have no impact, but in melanoma they are considered significant. The significance of sentinel lymph node metastasis tumor burden (including isolated tumor cells) and pattern of involvement in Merkel cell carcinoma are unknown. In this study, 64 Merkel cell carcinomas involving sentinel lymph nodes and corresponding immunohistochemical stains were reviewed and clinicopathological predictors of outcome were sought. Five metastatic patterns were identified: (1) sheet-like (n=38, 59%); (2) non-solid parafollicular (n=4, 6%); (3) sinusoidal, (n=11, 17%); (4) perivascular hilar (n=1, 2%); and (5) rare scattered parenchymal cells (n=10, 16%). At the time of follow-up, 30/63 (48%) patients had died with 21 (33%) attributable to Merkel cell carcinoma. Patients with pattern 1 metastases had poorer overall survival compared with patients with patterns 2-5 metastases (P=0.03), with 22/30 (73%) deaths occurring in pattern 1 patients. Three (10%) deaths occurred in patients showing pattern 5, all of whom were immunosuppressed. Four (13%) deaths occurred in pattern 3 patients and 1 (3%) death occurred in a pattern 2 patient. In multivariable analysis, the number of positive sentinel lymph nodes (1 or 2 versus >2, PMerkel cell carcinoma, the pattern of sentinel lymph node involvement provides important prognostic information and utilizing this data with other clinicopathological features facilitates risk stratification of Merkel cell carcinoma patients who may have management implications.

  16. Sentinel node biopsy (SNB) in malignant melanoma as same day procedure vs delayed procedure

    DEFF Research Database (Denmark)

    Rødgaard, Jes Christian; Kramer, Stine; Stolle, Lars B

    2013-01-01

    The aim of this study was to compare a delayed sentinel node biopsy (dSNB) procedure with a same-day procedure (sSNB) in malignant melanoma. In March 2012, Aarhus University Hospital went from the dSNB to the sSNB procedure defined by lymphoscintigraphy (LS) and sentinel node biopsy (SNB) perform......, essential to keep the morbidity and economic costs low, while keeping the quality of the procedure high....

  17. Lymphatic mapping and sentinel node biopsy in early stage melanoma: study of the first 100 cases in Institut Gustave Roussy

    International Nuclear Information System (INIS)

    Buffard, V.; Duvillard, P.; Mamelle, G.; Lumbroso, J.; Ricard, M.; Kolb, F.; Sleilati, F.; Spatz, A.

    2005-01-01

    Introduction: We report the data of the first 100 patients who underwent sentinel lymph node biopsy (SLND) in our institution using lymphoscintigraphy only. Patients and methods: From 1998 to 2000, 100 consecutive patients (53 men and 47 women) with stage I or II melanoma (mean Breslow: 3.11 mm) underwent a SLND. Localisation of the sentinel node was performed by preoperative lymphoscintigraphy and hand held gamma probe detection. The sentinel node was examined by routine histology and immunohistochemistry for PS100 and HMB-45. If the sentinel node contained tumor cells, a complete lymphadenectomy was performed. Results: Lymphoscintigraphy was performed for 97 patients. The SLN was identified in 97% of cases (94/97) and excised in 95% of cases (92/97). The rate of SLN metastasis was 19/92 patients (21%), correlated with Breslow index ( 4 mm: 46%). A mean number of 1.81 lymph node per patient was analysed. The mean follow-up was 26 months with a relapse in 14 patients, 5 of them having a metastatic sentinel node. Three patients had a recurrence at the site of the SLND although they had initially a negative sentinel node. Conclusion: The identification and metastatic rates of sentinel nodes are similar to those of the literature. More studies are needed to determine whether lymphoscintigraphy alone is efficient for successful SLND in melanoma. (author)

  18. 76 FR 30962 - Notice of Availability of Draft Environmental Impact Statement for the Sigurd to Red Butte No. 2...

    Science.gov (United States)

    2011-05-27

    ...; UTU-83067] Notice of Availability of Draft Environmental Impact Statement for the Sigurd to Red Butte..., as amended, the Bureau of Land Management (BLM) has prepared a Draft Environmental Impact Statement... Service; State of Utah; Millard, Sevier, Beaver, Iron, and Washington counties, Utah; and the cities of St...

  19. Riparian spiders as sentinels of polychlorinated biphenyl contamination across heterogeneous aquatic ecosystems.

    Science.gov (United States)

    Kraus, Johanna M; Gibson, Polly P; Walters, David M; Mills, Marc A

    2017-05-01

    Riparian spiders are being used increasingly to track spatial patterns of contaminants in and fluxing from aquatic ecosystems. However, our understanding of the circumstances under which spiders are effective sentinels of aquatic pollution is limited. The present study tests the hypothesis that riparian spiders may be effectively used to track spatial patterns of sediment pollution by polychlorinated biphenyls (PCBs) in aquatic ecosystems with high habitat heterogeneity. The spatial pattern of ΣPCB concentrations in 2 common families of riparian spiders sampled in 2011 to 2013 generally tracked spatial variation in sediment ΣPCBs across all sites within the Manistique River Great Lakes Area of Concern (AOC), a rivermouth ecosystem located on the south shore of the Upper Peninsula, Manistique (MI, USA) that includes harbor, river, backwater, and lake habitats. Sediment ΣPCB concentrations normalized for total organic carbon explained 41% of the variation in lipid-normalized spider ΣPCB concentrations across 11 sites. Furthermore, 2 common riparian spider taxa (Araneidae and Tetragnathidae) were highly correlated (r 2  > 0.78) and had similar mean ΣPCB concentrations when averaged across all years. The results indicate that riparian spiders may be useful sentinels of relative PCB availability to aquatic and riparian food webs in heterogeneous aquatic ecosystems like rivermouths where habitat and contaminant variability may make the use of aquatic taxa less effective. Furthermore, the present approach appears robust to heterogeneity in shoreline development and riparian vegetation that support different families of large web-building spiders. Environ Toxicol Chem 2017;36:1278-1286. Published 2016 Wiley Periodicals, Inc. on behalf of SETAC. This article is a US government work and, as such, is in the public domain in the United States of America. Published 2016 Wiley Periodicals, Inc. on behalf of SETAC. This article is a US government work and, as such, is in

  20. Sentinel Node Biopsy Alone versus Completion Axillary Node Dissection in Node Positive Breast Cancer: Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Rachna Ram

    2014-01-01

    Full Text Available Introduction. There has been recent interest in validity of completion axillary node dissection after a positive sentinel node. This systematic review aims to ascertain if sentinel lymph node dissection alone was noninferior to axillary lymph node dissection for breast cancer patients who have a positive sentinel node. Method. A systematic review of the electronic databases Embase, MEDLINE, and Cochrane Register of Controlled Trials was carried out. Only randomised trials that had patients with positive sentinel node as the study sample were included in the meta-analysis using the reported hazard ratios with a fixed effect model. Results. Three randomised controlled trials and five retrospective studies were identified. The pooled effect for overall survival was HR 0.94, 95% CI [0.79, 1.19], and for disease free survival was HR 0.83, 95% CI [0.60, 1.14]. The reported rates for locoregional recurrence were similar in both groups. The surgical morbidity was found to be significantly more in patients who had underwent axillary dissection. Conclusion. Amongst patients with micrometastasis in the sentinel node, no further axillary dissection is necessary. For patients with macrometastasis in the sentinel node, it is reasonable to consider omitting axillary dissection to avoid the morbidity of the procedure.

  1. Evaluating the capabilities of vegetation spectral indices on chlorophyll content estimation at Sentinel-2 spectral resolutions

    Science.gov (United States)

    Sun, Qi; Jiao, Quanjun; Dai, Huayang

    2018-03-01

    Chlorophyll is an important pigment in green plants for photosynthesis and obtaining the energy for growth and development. The rapid, nondestructive and accurate estimation of chlorophyll content is significant for understanding the crops growth, monitoring the disease and insect, and assessing the yield of crops. Sentinel-2 equipped with the Multi-Spectral Instrument (MSI), which will provide images with high spatial, spectral and temporal resolution. It covers the VNIR/SWIR spectral region in 13 bands and incorporates two new spectral bands in the red-edge region and a spatial resolution of 20nm, which can be used to derive vegetation indices using red-edge bands. In this paper, we will focus on assessing the potential of vegetation spectral indices for retrieving chlorophyll content from Sentinel-2 at different angles. Subsequently, we used in-situ spectral data and Sentinel-2 data to test the relationship between VIs and chlorophyll content. The REP, MTCI, CIred-edge, CIgreen, Macc01, TCARI/OSAVI [705,750], NDRE1 and NDRE2 were calculated. NDRE2 index displays a strongly similar result for hyperspectral and simulated Sentinel-2 spectral bands (R2 =0.53, R2 =0.51, for hyperspectral and Sentinel-2, respectively). At different observation angles, NDRE2 has the smallest difference in performance (R2 = 0.51, R2 =0.64, at 0° and 15° , respectively).

  2. The Western Environmental Technology Office (WETO), Butte, Montana. Technology summary (Revised)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This document has been prepared by the US Department of Energy`s (DOE`s) Office of Environmental Management (EM) Office of Science and Technology (OST) to highlight its research, development, demonstration, testing, and evaluation (RDDT&E) activities funded through the Western environmental Technology Office (WETO) in Butte, Montana. Technologies and processes described in this document have the potential to enhance DOE`s cleanup and waste management efforts, as well as improve US industry`s competitiveness in global environmental markets. The information presented in this document has been assembled from recently produced OST documents that highlight technology development activities within each of the OST program elements and Focus Areas. This document presents one in a series for each of DOE`s Operations Office and Energy Technology Centers.

  3. The Western Environmental Technology Office (WETO), Butte, Montana. Technology summary (Revised)

    International Nuclear Information System (INIS)

    1996-03-01

    This document has been prepared by the US Department of Energy's (DOE's) Office of Environmental Management (EM) Office of Science and Technology (OST) to highlight its research, development, demonstration, testing, and evaluation (RDDT ampersand E) activities funded through the Western environmental Technology Office (WETO) in Butte, Montana. Technologies and processes described in this document have the potential to enhance DOE's cleanup and waste management efforts, as well as improve US industry's competitiveness in global environmental markets. The information presented in this document has been assembled from recently produced OST documents that highlight technology development activities within each of the OST program elements and Focus Areas. This document presents one in a series for each of DOE's Operations Office and Energy Technology Centers

  4. SENTINEL-2 GLOBAL REFERENCE IMAGE VALIDATION AND APPLICATION TO MULTITEMPORAL PERFORMANCES AND HIGH LATITUDE DIGITAL SURFACE MODEL

    Directory of Open Access Journals (Sweden)

    A. Gaudel

    2017-05-01

    Full Text Available In the frame of the Copernicus program of the European Commission, Sentinel-2 is a constellation of 2 satellites with a revisit time of 5 days in order to have temporal images stacks and a global coverage over terrestrial surfaces. Satellite 2A was launched in June 2015, and satellite 2B will be launched in March 2017. In cooperation with the European Space Agency (ESA, the French space agency (CNES is in charge of the image quality of the project, and so ensures the CAL/VAL commissioning phase during the months following the launch. This cooperation is also extended to routine phase as CNES supports European Space Research Institute (ESRIN and the Sentinel-2 Mission performance Centre (MPC for validation in geometric and radiometric image quality aspects, and in Sentinel-2 GRI geolocation performance assessment whose results will be presented in this paper. The GRI is a set of S2A images at 10m resolution covering the whole world with a good and consistent geolocation. This ground reference enables accurate multi-temporal registration of refined Sentinel-2 products. While not primarily intended for the generation of DSM, Sentinel-2 swaths overlap between orbits would also allow for the generation of a complete DSM of land and ices over 60° of northern latitudes (expected accuracy: few S2 pixels in altimetry. This DSM would benefit from the very frequent revisit times of Sentinel-2, to monitor ice or snow level in area of frequent changes, or to increase measurement accuracy in areas of little changes.

  5. SENTINEL-2 Global Reference Image Validation and Application to Multitemporal Performances and High Latitude Digital Surface Model

    Science.gov (United States)

    Gaudel, A.; Languille, F.; Delvit, J. M.; Michel, J.; Cournet, M.; Poulain, V.; Youssefi, D.

    2017-05-01

    In the frame of the Copernicus program of the European Commission, Sentinel-2 is a constellation of 2 satellites with a revisit time of 5 days in order to have temporal images stacks and a global coverage over terrestrial surfaces. Satellite 2A was launched in June 2015, and satellite 2B will be launched in March 2017. In cooperation with the European Space Agency (ESA), the French space agency (CNES) is in charge of the image quality of the project, and so ensures the CAL/VAL commissioning phase during the months following the launch. This cooperation is also extended to routine phase as CNES supports European Space Research Institute (ESRIN) and the Sentinel-2 Mission performance Centre (MPC) for validation in geometric and radiometric image quality aspects, and in Sentinel-2 GRI geolocation performance assessment whose results will be presented in this paper. The GRI is a set of S2A images at 10m resolution covering the whole world with a good and consistent geolocation. This ground reference enables accurate multi-temporal registration of refined Sentinel-2 products. While not primarily intended for the generation of DSM, Sentinel-2 swaths overlap between orbits would also allow for the generation of a complete DSM of land and ices over 60° of northern latitudes (expected accuracy: few S2 pixels in altimetry). This DSM would benefit from the very frequent revisit times of Sentinel-2, to monitor ice or snow level in area of frequent changes, or to increase measurement accuracy in areas of little changes.

  6. Sentinel lymph node surgery in prostate cancer using magnetic particles.

    Science.gov (United States)

    Winter, Alexander; Engels, Svenja; Wawroschek, Friedhelm

    2018-03-01

    Superparamagnetic iron oxide nanoparticles (SPIONs) are tested to identify sentinel lymph nodes (SLNs) to exploit the advantages of targeted pelvic SLN dissection (sPLND), while circumventing the disadvantages of established radioactive labeling. Here we review recent studies about sPLND in prostate cancer (PCa), including the first results of SLN detection using intraprostatic SPION-injection. A recent systematic literature review reveals that the diagnostic accuracy of sPLND is comparable with extended PLND (ePLND). sPLND combined with ePLND achieve better node removal by increasing the number of affected nodes. The first sentinel-based nomogram predicting lymph node invasion is established. A sentinel-nomogram update provides comparative predictions relative to ePLND models. sPLND using a magnetometer and SPIONs as a tracer is successful whenever applied to PCa, and SLN identification using MRI after intraprostatic injection of SPIONs is feasible. SLNs are present in an unexpectedly high number outside the ePLND template. SLN detection outside the ePLND template and the increased diagnostic value of sPLND compared with ePLND supports the individualized extension of PLND using sPLND in PCa. SPION-MRI, combined with a hand-held magnetometer, provides a nonradioactive technique for preoperative and intraoperative SLN localization. Further studies are required to evaluate the effects of sPLND on oncological outcomes.

  7. The Use of Sentinel-1 Time-Series Data to Improve Flood Monitoring in Arid Areas

    Directory of Open Access Journals (Sweden)

    Sandro Martinis

    2018-04-01

    Full Text Available Due to the similarity of the radar backscatter over open water and over sand surfaces a reliable near real-time flood mapping based on satellite radar sensors is usually not possible in arid areas. Within this study, an approach is presented to enhance the results of an automatic Sentinel-1 flood processing chain by removing overestimations of the water extent related to low-backscattering sand surfaces using a Sand Exclusion Layer (SEL derived from time-series statistics of Sentinel-1 data sets. The methodology was tested and validated on a flood event in May 2016 at Webi Shabelle River, Somalia and Ethiopia, which has been covered by a time-series of 202 Sentinel-1 scenes within the period June 2014 to May 2017. The approach proved capable of significantly improving the classification accuracy of the Sentinel-1 flood service within this study site. The Overall Accuracy increased by ~5% to a value of 98.5% and the User’s Accuracy increased by 25.2% to a value of 96.0%. Experimental results have shown that the classification accuracy is influenced by several parameters such as the lengths of the time-series used for generating the SEL.

  8. Sentinel lymph node mapping and biopsy for melanoma in South Brazil

    International Nuclear Information System (INIS)

    Junqueira, G. Jr.; Bodanese, B.; Boff, M.F.; Espindola, M.B.; Haack, R.L.; Frigeri, C.D.L.

    2004-01-01

    Full text: The presence or absence of regional nodal metastases is one of the most important prognostic factors in the survival of patients with primary cutaneous melanoma. Unfortunately, the complications of lymphadenectomy can be significant. An approach that permits accurate staging of the regional nodes without complete lymphadenectomy is sentinel lymph node (SLN) biopsy. We reviewed the records of 107 patients with primary cutaneous melanoma who underwent lymphatic mapping and SLN biopsy from November 2000 to May 2003. In all patients the primary melanoma was at least 1.0 mm thick, if less than 1.0 mm, was at least Clark's level IV or ulcerated or demonstrated evidence of regression if the patient had no evidence of metastatic melanoma in regional lymph nodes and distant sites. All patients underwent preoperative lymphoscintigraphy to identify the lymphatic basin and the site of the sentinel node. All patients subsequently underwent intra-operative lymphatic mapping and selective lymph node biopsy with blue dye and hand-held gamma probe. Excised SLN were analyzed by conventional histological staining (H and E). Immuno-histochemical staining was also performed if the initial pathologic examination was negative. 107 patients (58 female) were subjected to sentinel node biopsy from November 2000 to May 2003. The primary tumor was in arm in 11.2%, legs in 29.9%, trunk in 53,3% and head and neck in 4.6% patients. 72.9% lesions were superficial spreading type and 49.5% were Clark's IV level. The sentinel node biopsy was positive in 13 (12.2%) patients. Our study thus suggests that SLN biopsy improves the accuracy of staging and provides valuable prognostic information to physicians to guide subsequent treatment decisions and facilitates early therapeutic lymph node dissection in patients having nodal metastases. (author)

  9. Primary water stress corrosion cracking resistance of alloy 690 heat affected zones of butt welds

    International Nuclear Information System (INIS)

    Fournier, L.; Calonne, O.; Toloczko, M.B.; Bruemmer, S.M.; Massoud, J.P.; Lemaire, E.; Gerard, R.; Somville, F.; Richnau, A.; Lagerstrom, J.

    2015-01-01

    A wide V-groove butt weld was fabricated from Alloy 690 plates using Alloy 152 filler material, maximum allowable heat input, and very stiff strong-backs. Alloy 690 heat affected zones (HAZ) was characterized in terms of microstructure and plastic strains induced by weld shrinkage. Crack initiation tests were carried out in pure hydrogenated steam at 400 C. degrees for 4000 h. Crack growth rate tests were performed in simulated PWR primary water at a temperature of 360 C. degrees. A maximum plastic strain around 5% was measured in the vicinity of the fusion line, which decreased almost linearly with the distance from the fusion line. Crack initiation tests on Alloy 690 HAZ specimens as well as on 30% cold-rolled Alloy 690 specimens were performed in pure hydrogenated steam at 400 C. degrees (partial pressure of hydrogen = 0.7 bar) for a total of 4000 h using cylindrical notched tensile specimens, reverse U-bends and flat micro-tensile specimens. No crack initiation was detected. Stress corrosion propagation rates revealed extremely low SCC (Stress Corrosion Cracking) growth rates both in the base metal and in the HAZ region whose magnitudes are of no engineering significance. Overall, the results indicated limited plastic strain induced by weld shrinkage in butt weld HAZ, and to no particular susceptibility of primary water stress corrosion cracking. (authors)

  10. The organizational structure and governing principles of the Food and Drug Administration's Mini-Sentinel pilot program.

    Science.gov (United States)

    Forrow, Susan; Campion, Daniel M; Herrinton, Lisa J; Nair, Vinit P; Robb, Melissa A; Wilson, Marcus; Platt, Richard

    2012-01-01

    The US Food and Drug Administration's Mini-Sentinel pilot program is developing an organizational structure as well as principles and policies to govern its operations. These will inform the structure and function of the eventual Sentinel System. Mini-Sentinel is a collaboration that includes 25 participating institutions. We describe the program's current organizational structure and its major principles and policies. The organization includes a coordinating center with program leadership provided by a principal investigator; a planning board and subcommittees; an operations center; and data, methods, and protocol cores. Ad hoc workgroups are created as needed. A privacy panel advises about protection of individual health information. Principles and policies are intended to ensure that Mini-Sentinel conforms to the principles of fair information practices, protects the privacy of individual health information, maintains the security and integrity of data, assures the confidentiality of proprietary information, provides accurate and timely communications, prevents or manages conflicts of interest, and preserves respect for intellectual property rights. Copyright © 2012 John Wiley & Sons, Ltd.

  11. Mass Processing of Sentinel-1 Images for Maritime Surveillance

    Directory of Open Access Journals (Sweden)

    Carlos Santamaria

    2017-07-01

    Full Text Available The free, full and open data policy of the EU’s Copernicus programme has vastly increased the amount of remotely sensed data available to both operational and research activities. However, this huge amount of data calls for new ways of accessing and processing such “big data”. This paper focuses on the use of Copernicus’s Sentinel-1 radar satellite for maritime surveillance. It presents a study in which ship positions have been automatically extracted from more than 11,500 Sentinel-1A images collected over the Mediterranean Sea, and compared with ship position reports from the Automatic Identification System (AIS. These images account for almost all the Sentinel-1A acquisitions taken over the area during the two-year period from the start of the operational phase in October 2014 until September 2016. A number of tools and platforms developed at the European Commission’s Joint Research Centre (JRC that have been used in the study are described in the paper. They are: (1 Search for Unidentified Maritime Objects (SUMO, a tool for ship detection in Synthetic Aperture Radar (SAR images; (2 the JRC Earth Observation Data and Processing Platform (JEODPP, a platform for efficient storage and processing of large amounts of satellite images; and (3 Blue Hub, a maritime surveillance GIS and data fusion platform. The paper presents the methodology and results of the study, giving insights into the new maritime surveillance knowledge that can be gained by analysing such a large dataset, and the lessons learnt in terms of handling and processing the big dataset.

  12. Potential of future operational missions sentinel 4 and 5 for atmospheric monitoring and science (CAMELOT).

    Science.gov (United States)

    Levelt, P. F.; Veefkind, J. P.

    2010-05-01

    Dedicated atmospheric chemistry observations from space have been made for over 30 years now, starting with the SBUV and TOMS measurements of the ozone layer. Since then huge progress has been made, improving the accuracy of the measurements, extending the amount of constituents, and by sensing not only the stratosphere, but the last five to ten years also the troposphere. The potential to operational monitor the atmosphere, following the meteorological community, came within reach. At the same time, the importance for society of regular operational environmental measurements, related to the ozone layer, air quality and climate change, became apparent, amongst others resulting in the EU initiative Global Monitoring for Environment and Security (GMES) In order to prepare the operational missions in the context of the GMES, ESA took the initiative to further study the user requirements for the Sentinel 4 and 5 (precursor) missions. The Sentinel 4 and 5 (precursor) missions are dedicated operational missions to monitor the atmospheric composition in the 2013-2020 timeframe and onward. The user requirements for the sentinel missions focus on monitoring the atmosphere from an environmental point of view (ozone layer, air quality and climate). ESA's CAMELOT (Composition of the Atmospheric Mission concEpts and SentineL Observation Techniques) study is the follow-on study to ESA's CAPACITY study finished in 2005. The general objective of the CAMELOT study is to further contribute to the definition of the air quality and climate protocol monitoring parts of the GMES Sentinel 4 and 5 missions. CAMELOT consists of a large European consortium formed by 9 European institutes (KNMI (lead), RAL, U.Leicester, SRON, FMI, BIRA-IASB, CNR-IFAC,NOVELTIS and RIU-U.Koeln). In the presentation an overview will give a short overview of the CAMELOT study, including some specific results for combined retrievals, cloud statistics for different orbit geometries and retrievals for several orbit

  13. One-inch field of view imaging probe for breast cancer sentinel node location

    International Nuclear Information System (INIS)

    D'Errico, Giovanni; Scafe, Raffaele; Soluri, Alessandro; Schiaratura, Alfiero; Maria Mangano, Anna; David, Vincenzo; Scopinaro, Francesco

    2003-01-01

    The already reported 1-in. 2 field of view mini gamma camera known since 1998 with the name of Imaging Probe (IP), has been used for sentinel node localization by a medical equipe that, though trained by the group of nuclear physicians of the University 'La Sapienza' who first conceived and used this detector, has used IP in its own Hospital to: (1) gain experience for future use during operations--a cooperative work on IP radio guided orthopaedic operations has already started working, and (2) to start with IP multicenter trials. In six patients with breast cancer, who underwent lymphoscintigraphy for sentinel node biopsy, sentinel node was checked and located with IP and non-imaging Neoprobe 2000 CdTe (Zn) probe, independent of location by means of large field of view Anger camera. Operators who used Neoprobe and IP were blinded to each other and not aware of the results of Anger camera imaging. Anger camera, as well as IP and neoprobe detected 7 nodes in 6 pts. Detection time was 2', 06'' SD 26'' with IP and 2', 18'' SD 47'' with neoprobe 2000. The most difficult to find node required 2 min and 56 s--inside sd--for IP detection and 3 min and 45 s with neoprobe. Subjective impression of being sure of having detected sentinel node was: absolutely sure on 7/7 nodes with IP and on 5/7 nodes with neoprobe

  14. Wintercuring of Prunus dulcis cv ‘Butte,’ P. webbii and their interspecific hybrid in response to Xylella fastidiosa infections

    Science.gov (United States)

    Clonal replicates of Prunus dulcis cv ‘Butte,’ P. webbii and their interspecific hybrid P 63-61 were inoculated with Xylella fastidiosa strain M23 and evaluated for Almond Leaf Scorch Disease and subsequent wintercuring of infections during three growing seasons. Initial inoculations established gr...

  15. Potentiality of SENTINEL-1 for landslide detection: first results in the Molise Region (Italy)

    Science.gov (United States)

    Barra, Anna; Monserrat, Oriol; Mazzanti, Paolo; Esposito, Carlo; Crosetto, Michele; Scarascia Mugnozza, Gabriele

    2016-04-01

    A detailed inventory map, including information on landslide activity, is one of the most important input to landslide susceptibility and hazard analyses. The contribution of satellite SAR Interferometry in landslide risk mitigation is well-known within the scientific community. In fact, many encouraging results have been obtained, principally, in areas characterized by high coherence of the images (e.g. due to rock lithology or urban environment setting). In terms of coherence, the expected increased capabilities of Sentinel-1 for landslide mapping and monitoring are connected to both wavelength (55.5 mm) and short temporal baseline (12 days). The latter one is expected to be a key feature for increasing coherence and for defining monitoring and updating plans. With the aim of assessing these potentialities, we processed a set of 14 Sentinel-1 SLC images, acquired during a temporal span of 7 months, over the Molise region (Southern Italy), a critical area geologically susceptible to landslides. Even though Molise is mostly covered by crops and forested areas (63% and 35% respectively), that means a non-optimal coherence condition for SAR interferometry, promising results have been obtained. This has been achieved by integrating differential interferometric SAR techniques (12-days interferograms and time series) with GIS multilayer analysis (optical, geological, geomorphological, etc.). Specifically, analyzing a single burst of a Sentinel-1 frame (approximately 1875 km2), 62 landslides have been detected, thus allowing to improve the pre-existing inventory maps both in terms of landslide boundaries and state of activity. The results of our ongoing research show that Sentinel-1 can give a significant improvement in terms of exploitation of SAR data for landslide mapping and monitoring. As a matter of fact, by analyzing longer periods, it is expected to achieve a better understanding of landslide behavior and its relationship with triggering factors. This will be key

  16. Capturing pre-failure signs of slope instability using multi-temporal interferometry and Sentinel-1 data

    Science.gov (United States)

    Wasowski, Janusz; Bovenga, Fabio; Nitti, Davide Oscar; Tijani, Khalid; Morea, Alberto; Nutricato, Raffaele; Chiaradia, Maria Teresa

    2017-04-01

    The shorter repeat cycle (6 days since October 2016) and regularity of acquisitions of Sentinel-1A/B with respect to earlier European Space Agency (ESA) satellites with C-band sensors (ERS1/2, ENVISAT) represent the key advantages for the research-oriented and practical applications of multi-temporal interferometry (MTI). The applicability of the Interferometric Wide Swath acquisition mode of Sentinel-1 (images covering a 250 km swath on the ground) to regional scale slope instability detection through MTI has already been demonstrated, e.g., via studies of landslide-prone areas in Italy. Here we focus on the potential of Sentinel-1 data for local (site-specific), MTI-based monitoring and capturing pre-failure signs of slope instability, by exploiting the Persistent and Distributed Scatterers processing capability of the SPINUA algorithm. In particular, we present an example of a retrospective study of a large (over 2 km long) landslide, which took place in 2016 in an active open-cast coal mine in central Europe. This seemingly sudden failure caused destruction of the mining equipment, blocked the mining operations thereby resulting in significant economic losses. For the study, we exploited over 60 Sentinel-1A/B images acquired since November 2014. The MTI results furnished a valuable overview of the ground instability/stability conditions within and around the active mine, even though considerable spatial gaps in information were encountered due to surface disturbance by mining operations. Significantly, the ground surface displacement time series revealed that the 2016 slope failure was preceded by very slow (generally 1-3 cm/yr) creep-like deformations, already present in 2014. The MTI results also indicated that the slope experienced a phase of accelerated movement several weeks prior to the landslide event. Furthermore, the spatio-temporal analysis of interferometric coherence changes in the unstable area (mapped on Sentinel-2 Bottom Of Atmosphere reflectance

  17. Soil Moisture Retrieval and Spatiotemporal Pattern Analysis Using Sentinel-1 Data of Dahra, Senegal

    Directory of Open Access Journals (Sweden)

    Zhiqu Liu

    2017-11-01

    Full Text Available The spatiotemporal pattern of soil moisture is of great significance for the understanding of the water exchange between the land surface and the atmosphere. The two-satellite constellation of the Sentinel-1 mission provides C-band synthetic aperture radar (SAR observations with high spatial and temporal resolutions, which are suitable for soil moisture monitoring. In this paper, we aim to assess the capability of pattern analysis based on the soil moisture retrieved from Sentinel-1 time-series data of Dahra in Senegal. The look-up table (LUT method is used in the retrieval with the backscattering coefficients that are simulated by the advanced integrated equation Model (AIEM for the soil layer and the Michigan microwave canopy scattering (MIMICS model for the vegetation layer. The temporal trend of Sentinel-1A soil moisture is evaluated by the ground measurements from the site at Dahra, with an unbiased root-mean-squared deviation (ubRMSD of 0.053 m3/m3, a mean average deviation (MAD of 0.034 m3/m3, and an R value of 0.62. The spatial variation is also compared with the existing microwave products at a coarse scale, which confirms the reliability of the Sentinel-1A soil moisture. The spatiotemporal patterns are analyzed by empirical orthogonal functions (EOF, and the geophysical factors that are affecting soil moisture are discussed. The first four EOFs of soil moisture explain 77.2% of the variance in total and the primary EOF explains 66.2%, which shows the dominant pattern at the study site. Soil texture and the normalized difference vegetation index are more closely correlated with the primary pattern than the topography and temperature in the study area. The investigation confirms the potential for soil moisture retrieval and spatiotemporal pattern analysis using Sentinel-1 images.

  18. Murine norovirus detection in the exhaust air of IVCs is more sensitive than serological analysis of soiled bedding sentinels.

    Science.gov (United States)

    Zorn, Julia; Ritter, Bärbel; Miller, Manuel; Kraus, Monika; Northrup, Emily; Brielmeier, Markus

    2017-06-01

    One limitation to housing rodents in individually ventilated cages (IVCs) is the ineffectiveness of traditional health monitoring programs that test soiled bedding sentinels every quarter. Aerogen transmission does not occur with this method. Moreover, the transmission of numerous pathogens in bedding is uncertain, and sentinel susceptibility to various pathogens varies. A novel method using particle collection from samples of exhaust air was developed in this study which was also systematically compared with routine health monitoring using soiled bedding sentinels. We used our method to screen these samples for the presence of murine norovirus (MNV), a mouse pathogen highly prevalent in laboratory animal facilities. Exhaust air particles from prefilters of IVC racks with known MNV prevalence were tested by quantitative reverse transcription polymerase chain reaction (RT-qPCR). MNV was detected in exhaust air as early as one week with one MNV-positive cage per rack, while sentinels discharged MNV RNA without seroconverting. MNV was reliably and repeatedly detected in particles collected from samples of exhaust air in all seven of the three-month sampling rounds, with increasing MNV prevalence, while sentinels only seroconverted in one round. Under field conditions, routine soiled bedding sentinel health monitoring in our animal facility failed to identify 67% ( n = 85) of positive samples by RT-qPCR of exhaust air particles. Thus, this method proved to be highly sensitive and superior to soiled bedding sentinels in the reliable detection of MNV. These results represent a major breakthrough in hygiene monitoring of rodent IVC systems and contribute to the 3R principles by reducing the number of animals used and by improving experimental conditions.

  19. Correlation of number and identification of sentinel nodes during radiographer led lymphoscintigraphy prior to sentinel lymph node biopsy in breast cancer patients

    International Nuclear Information System (INIS)

    Camilleri, Gail; Borg Grima, Karen; Zarb, Francis

    2012-01-01

    Purpose: The sentinel lymph node biopsy (SLNB) concept using the cutaneous (subdermal) peri-areolar approach is rapidly emerging as the technique for axillary staging in breast cancer. The procedure indicates whether axillary lymph node dissection (ALND) is necessary, therefore drastically minimising the invasiveness of surgical treatment. The SLNB concept is based on evidence suggesting that malignant disease primarily affects the sentinel node (SN) before being disseminated into the axillary lymph nodes (ALNs). Objective: This study was to define the role of lymphoscintigraphy in the visualisation of SNs during SLNB and to establish the correlation between the number of SNs identified on lymphoscintigraphy to the number of surgically identified SNs. Method: The study was a non-experimental, correlation study utilising quantitative data. Lymphoscintigraphy reports and histology results of 55 female breast cancer patients who underwent SLNB with partial or total back-up ALND, were retrospectively evaluated. Results: A maximum of 2 and a minimum of 0 sentinel nodes were visualised on lymphoscintigraphy in 52 out of 55 patients. Successful lymphoscintigraphy was highly predictive (p ≤ 0.001) of a successful SLNB as all 52 patients (94.5%) proceeded to have successful SN/s identification. There was a significant association (p ≤ 0.05) between the number of SN/s visualised on lymphoscintigraphy and the number of SN/s identified during SLNB. Lymphoscintigraphy accurately predicted the number of surgically identified SNs in 50.91% of cases (28/55). Conclusion: Considering that successful imaging effectively assures SN identification, the routine use of lymphoscintigraphy using the subdermal peri-areolar approach is fundamental in the reliable performance of SLNB.

  20. Detection of Irrigated Crops from Sentinel-1 and Sentinel-2 Data to Estimate Seasonal Groundwater Use in South India

    Directory of Open Access Journals (Sweden)

    Sylvain Ferrant

    2017-11-01

    Full Text Available Indian agriculture relies on monsoon rainfall and irrigation from surface and groundwater. The interannual variability of monsoon rainfalls is high, which forces South Indian farmers to adapt their irrigated areas to local water availability. In this study, we have developed and tested a methodology for monitoring these spatiotemporal variations using Sentinel-1 and -2 observations over the Kudaliar catchment, Telangana State (~1000 km2. These free radar and optical data have been acquired since 2015 on a weekly basis over continental areas, at a high spatial resolution (10–20 m that is well adapted to the small areas of South Indian field crops. A machine learning algorithm, the Random Forest method, was used over three growing seasons (January to March and July to November 2016 and January to March 2017 to classify small patches of inundated rice paddy, maize, and other irrigated crops, as well as surface water stored in the small reservoirs scattered across the landscape. The crop production comprises only irrigated crops (less than 20% of the areas during the dry season (Rabi, December to March, to which rain-fed cotton is added to reach 60% of the areas during the monsoon season (Kharif, June to November. Sentinel-1 radar backscatter provides useful observations during the cloudy monsoon season. The lowest irrigated area totals were found during Rabi 2016 and Kharif 2016, accounting for 3.5 and 5% with moderate classification confusion. This confusion decreases with increasing areas of irrigated crops during Rabi 2017. During this season, 16% of rice and 6% of irrigated crops were detected after the exceptional rainfalls observed in September. Surface water in small surface reservoirs reached 3% of the total area, which corresponds to a high value. The use of both Sentinel datasets improves the method accuracy and strengthens our confidence in the resulting maps. This methodology shows the potential of automatically monitoring, in near

  1. A 1 cm space debris impact onto the Sentinel-1A solar array

    Science.gov (United States)

    Krag, H.; Serrano, M.; Braun, V.; Kuchynka, P.; Catania, M.; Siminski, J.; Schimmerohn, M.; Marc, X.; Kuijper, D.; Shurmer, I.; O'Connell, A.; Otten, M.; Muñoz, Isidro; Morales, J.; Wermuth, M.; McKissock, D.

    2017-08-01

    Sentinel-1A is a 2-ton spacecraft of the Copernicus Earth observation program operated by ESA's Space Operations Centre in Darmstadt, Germany. Sentinel-1A and its sister spacecraft Sentinel-1B operate in a sun-synchronous orbit at about 700 km altitude. On 2016/08/23 17:07:37 UTC, Sentinel-1A suffered from an anomaly resulting in a sudden permanent partial power loss and significant impulsive orbit and attitude changes. A deeper investigation identified that an impulsive orbit change against flight direction of 0.7 mm/s, estimated at the time of the event, gave the best results in terms of GPS residuals. At the same time, a peak attitude off-pointing of 0.7° (around the spacecraft yaw axis) and peak attitude rate increase of 0.04°/s (around the same axis) were observed. The simultaneous occurrence of these anomalies, starting from a sudden attitude change and ending with a permanent partial power loss, made an MMOD (Micro-Meteoroid and Orbital Debris) impact onto a solar array a possible explanation for this event. While the spacecraft is able to continue its mission nominally, a detailed investigation involving ESA's Space Debris and Flight Dynamics experts was conducted. An MMOD impact as an explanation gained further credibility, due to the pictures of the solar array taken by the on-board camera displaying a significant damage area. On September 7th, JSpOC (US Joint Space Operations Centre) informed SDO on 8 tracked fragments that are considered to be released by Sentinel-1A after the impact. This paper addresses the analysis that was performed on the data characterising the attitude and orbit change, the on-board camera image, and the tracked fragments. The data helped to identify the linear momentum vector while a flux analysis helped to identify the origin of the impactor and allowed to understand its mass and size characteristics.

  2. Assessing Vegetation Response to Soil Moisture Fluctuation under Extreme Drought Using Sentinel-2

    Directory of Open Access Journals (Sweden)

    Harry West

    2018-06-01

    Full Text Available The aim of this study was to determine the extent to which Sentinel-2 Normalised Difference Vegetation Index (NDVI reflects soil moisture conditions, and whether this product offers an improvement over Landsat-8. Based on drought exposure, cloud-free imagery availability, and measured soil moisture, five sites in the Southwestern United States were selected. These sites, normally dry to arid, were in various states of drought. A secondary focus was therefore the performance of the NDVI under extreme conditions. Following supervised classification, the NDVI values for one-kilometre radius areas were calculated. Sentinel-2 NDVI variants using Spectral Bands 8 (10 m spatial resolution, 5, 6, 7, and 8A (20 m spatial resolution were calculated. Landsat-8 NDVI was calculated at 30 m spatial resolution. Pearson correlation analysis was undertaken for NDVI against moisture at various depths. To assess the difference in correlation strength, a principal component analysis was performed on the combination of all bands and the combination of the new red-edge bands. Performance of the red-edge NDVI against the standard near infrared (NIR was then evaluated using a Steiger comparison. No significant correlations between Landsat-8 NDVI and soil moisture were found. Significant correlations at depths of less than 30 cm were present between Sentinel-2 NDVI and soil moisture at three sites. The remaining two sites were characterised by low vegetation cover, suggesting a cover threshold of approximately 30–40% is required for a correlation to be present. At all sites of significant positive moisture to NDVI correlation, the linear combination of the red-edge bands produced stronger correlations than the poorer spectral but higher spatial resolution band. NDVI calculated using the higher spectral resolution bands may therefore be of greater use in this context than the higher spatial resolution option. Results suggest potential for the application of Sentinel-2

  3. Estimation and mapping of above-ground biomass of mangrove forests and their replacement land uses in the Philippines using Sentinel imagery

    Science.gov (United States)

    Castillo, Jose Alan A.; Apan, Armando A.; Maraseni, Tek N.; Salmo, Severino G.

    2017-12-01

    The recent launch of the Sentinel-1 (SAR) and Sentinel-2 (multispectral) missions offers a new opportunity for land-based biomass mapping and monitoring especially in the tropics where deforestation is highest. Yet, unlike in agriculture and inland land uses, the use of Sentinel imagery has not been evaluated for biomass retrieval in mangrove forest and the non-forest land uses that replaced mangroves. In this study, we evaluated the ability of Sentinel imagery for the retrieval and predictive mapping of above-ground biomass of mangroves and their replacement land uses. We used Sentinel SAR and multispectral imagery to develop biomass prediction models through the conventional linear regression and novel Machine Learning algorithms. We developed models each from SAR raw polarisation backscatter data, multispectral bands, vegetation indices, and canopy biophysical variables. The results show that the model based on biophysical variable Leaf Area Index (LAI) derived from Sentinel-2 was more accurate in predicting the overall above-ground biomass. In contrast, the model which utilised optical bands had the lowest accuracy. However, the SAR-based model was more accurate in predicting the biomass in the usually deficient to low vegetation cover non-forest replacement land uses such as abandoned aquaculture pond, cleared mangrove and abandoned salt pond. These models had 0.82-0.83 correlation/agreement of observed and predicted value, and root mean square error of 27.8-28.5 Mg ha-1. Among the Sentinel-2 multispectral bands, the red and red edge bands (bands 4, 5 and 7), combined with elevation data, were the best variable set combination for biomass prediction. The red edge-based Inverted Red-Edge Chlorophyll Index had the highest prediction accuracy among the vegetation indices. Overall, Sentinel-1 SAR and Sentinel-2 multispectral imagery can provide satisfactory results in the retrieval and predictive mapping of the above-ground biomass of mangroves and the replacement

  4. CTC Sentinel. Volume 9, Issue 2, February 2016

    Science.gov (United States)

    2016-06-02

    Islamic State side. See Derek Henry Flood: “The Islamic State Raises Its Black Flag Over The Caucasus,” CTC Sentinel 8:6 (2015): pp. 1-4. Dr. Guido...Qalamun,” [Hezbollah Holds Funeral for Child Killed in Al-Qalamun], Al-Araby Al-Jadid, April 28, 2015. 2 Lin Jenkins , “Isis video shows killing of

  5. Sentinel Lymph Node Dissection in Locally Recurrent Breast Cancer

    DEFF Research Database (Denmark)

    Uth, Charlotte Caspara; Christensen, Mette Haulund; Oldenbourg, Mette Holmqvist

    2015-01-01

    BACKGROUND: The aim of this study was to investigate the use of sentinel lymph node dissection (SLND) in the treatment of patients with locally recurrent breast cancer. METHODS: A total of 147 patients with locally recurrent breast cancer were included from five different breast surgery departments...

  6. Songbirds as sentinels of mercury in terrestrial habitats of eastern North America

    Science.gov (United States)

    Jackson, Allyson K.; Evers, David C.; Adams, Evan M.; Cristol, Daniel A.; Eagles-Smith, Collin A.; Edmonds, Samuel T.; Gray, Carrie E.; Hoskins, Bart; Lane, Oksana P.; Sauer, Amy; Tear, Timothy

    2015-01-01

    Mercury (Hg) is a globally distributed environmental contaminant with a variety of deleterious effects in fish, wildlife, and humans. Breeding songbirds may be useful sentinels for Hg across diverse habitats because they can be effectively sampled, have well-defined and small territories, and can integrate pollutant exposure over time and space. We analyzed blood total Hg concentrations from 8,446 individuals of 102 species of songbirds, sampled on their breeding territories across 161 sites in eastern North America [geometric mean Hg concentration = 0.25 μg/g wet weight (ww), range freshwater or estuarine) than upland forests. Generally, adults exhibited higher blood Hg concentrations than juveniles within each habitat type. We used model results to examine species-specific differences in blood Hg concentrations during this time period, identifying potential Hg sentinels in each region and habitat type. Our results present the most comprehensive assessment of blood Hg concentrations in eastern songbirds to date, and thereby provide a valuable framework for designing and evaluating risk assessment schemes using sentinel songbird species in the time after implementation of the new atmospheric Hg standards.

  7. Enhanced Sentinel Lymphoscintigraphic Mapping in Breast Tumor Using the Graded Shield Technique

    Directory of Open Access Journals (Sweden)

    Yu-Wen Chen

    2003-07-01

    Full Text Available The graded shield technique was developed to increase the sentinel node detection rate by improving lymphoscintigraphic image contrast. In a 6-month period, 50 women with clinical suspicion of early stage breast cancer (T1 and T2 tumors were enrolled in this study. The patients had a mean age of 47.2 ± 10.3 years. A composite graded shield was constructed using three concentric layers of leaded plastic measuring 3 cm, 5 cm, and 7 cm each in diameter. The graded shield was designed with a movable Velcro backing for accurate positioning over the injection site. Images were acquired with a vertical angle dual-head gamma camera using an established injection procedure developed at our institution. The rate of detection of sentinel lymph nodes using lymphoscintigraphic mapping improved from 74% (37/50 patients to 96% (48/50 using the graded shield (p < 0.05. In addition to the increased detection rate, our technique also increased the number of nodes detected and improved visualization of the adjacent lymphatic basin. By enhancing nodal contrast, we have demonstrated that the graded shield technique is an effective method for improving the rate of sentinel node detection.

  8. Sentinel lymph node biopsy: is it possible to reduce false negative rates by excluding patients with nodular melanoma?

    LENUS (Irish Health Repository)

    Corrigan, M A

    2012-02-03

    OBJECTIVE: The aim of this study was to review the outcome of sentinel lymph node biopsy (SLNB) in patients with melanoma and to delineate whether patients with nodular melanoma are more likely to develop nodal recurrence despite negative SLNB. METHODS: Consecutive patients with cutaneous melanoma undergoing SLNB were identified from a departmental database between 1997 and 2005. Factors including demographic data, site, histological subtype, depth and outcome were examined. RESULTS: Of 131 patients, 103 were node negative and eligible for study. The median age was 53 (16-82) years with 46 patients being male (45%) and 57 female (55%). Primary melanoma sites included lower limb (49; 48%), upper limb (29; 28%), head (12; 11%), trunk (7; 7%) and back (6; 6%). The median Breslow thickness was 2mm. Superficial spreading accounted for 43% of melanoma with nodular accounting for 42%. Median follow-up was 40 (3-90) months. Of 20 relapses, seven recurred in the same nodal basin, three were satellite recurrences, one recurred with both satellite and nodal lesions simultaneously, and nine experienced haematogenous spread. Of the eight patients who developed recurrence in the same nodal basin, four were of nodular histological subtype (p=NS). All of the three patients with satellite lesions had nodular melanoma histologically (p=0.02). When nodal and satellite recurrences were combined, eight of 11 were histologically nodular (p=0.01). CONCLUSIONS: This study indicates that lymphatic recurrence occurs more often in SLNB negative patients with nodular melanoma. Further evaluation of the inclusion criteria for sentinel node biopsy is warranted.

  9. The Western Environmental Technology Office (WETO), Butte, Montana, technology summary

    International Nuclear Information System (INIS)

    1994-09-01

    This document has been prepared by the DOE Environmental Management (EM) Office of Technology Development (OTD) to highlight its research, development, demonstration, testing, and evaluation activities funded through the Western Environmental Technology Office (WETO) in Butte, Montana. Technologies and processes described have the potential to enhance DOE's cleanup and waste management efforts, as well as improve US industry's competitiveness in global environmental markets. WETO's environmental technology research and testing activities focus on the recovery of useable resources from waste. Environmental technology development and commercialization activities will focus on mine cleanup, waste treatment, resource recovery, and water resource management. Since the site has no record of radioactive material use and no history of environmental contamination/remediation activities, DOE-EM can concentrate on performing developmental and demonstration activities without the demands of regulatory requirements and schedules. Thus, WETO will serve as a national resource for the development of new and innovative environmental technologies

  10. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer

    International Nuclear Information System (INIS)

    Vasques, Paulo Henrique Diogenes; Aquino, Ranniere Gurgel Furtado de; Pinheiro, Luiz Gonzaga Porto; Torres, Roberto Vitor Almeida; Bezerra, Jose Lucas Martins; Brasileiro, Luis Porto

    2015-01-01

    Purpose: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Methods: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. Results: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Conclusion: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy. (author)

  11. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vasques, Paulo Henrique Diogenes; Aquino, Ranniere Gurgel Furtado de; Pinheiro, Luiz Gonzaga Porto, E-mail: luizgporto@uol.com.br [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Departamento de Cirurgia; Alves, Mayara Maia [Rede Nordeste de Biotecnologia (RENORBIO/UFC), Fortaleza, CE (Brazil); Torres, Roberto Vitor Almeida; Bezerra, Jose Lucas Martins [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Faculdade de Medicina; Brasileiro, Luis Porto [Faculdades INTA, Sobral, CE (Brazil). Faculdade de Medicina

    2015-11-15

    Purpose: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Methods: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. Results: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Conclusion: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy. (author)

  12. Residual-stress distributions near stainless steel butt weldments

    International Nuclear Information System (INIS)

    Elligson, W.A.; Shack, W.J.

    1978-01-01

    Concern for the integrity of stainless steel butt-weldments in boiling-water-reactor (BWR) piping systems has stimulated study of the conditions that cause stress corrosion cracking (SCC) in the heat-affected zones (HAZ) of the weldments. It is generally agreed that a high stress exceeding the initial yield strength is one of the essential elements for crack initiation. Since design procedures usually ensure that load stresses are below initial yield, the source of the high stresses necessary to produce SCC is thought to be the residual stresses due to welding. To examine the level of residual stresses in the weldments of interest, bulk residual stresses were measured on 100 mm (4-in.) and 254 mm (10-in.) diameter Schedule 80 piping weldments using strain relief techniques. Both laboratory welded specimens and field welded specimens from reactors in service were studied. Axial bulk residual stress distributions were obtained at 45 0 intervals around the circumference. At each azimuthal position, the residual stresses were measured at seven axial positions: on the weld centerline and 13, 20, and 25 mm on either side of the weld centerline on both the inside and outside surfaces

  13. Fire monitoring capability of the joint Landsat and Sentinel 2 constellation

    Science.gov (United States)

    Murphy, S.; Wright, R.

    2017-12-01

    Fires are a global hazard. Landsat and Sentinel 2 can monitor the Earth's surface every 2 - 4 days. This provides an important opportunity to complement the operational (lower resolution) fire monitoring systems. Landsat-class sensors can detect small fires that would be missed by MODIS-classed sensors. All large fires start out as small fires. We analyze fire patterns in California from 1984 to 2017 and compare the performance of Landsat-type and MODIS-type sensors. Had an operational Landsat-Sentinel 2 fire detection system been in place at the time of the Soberanes fire last year (i.e. August 2016), the cost of suppressing of this fire event (US $236 million) could potentially have been reduced by an order of magnitude.

  14. 78 FR 67168 - Sixth Annual Sentinel Initiative; Public Workshop

    Science.gov (United States)

    2013-11-08

    ... projects that would be appropriate to determine the feasibility of using Sentinel to evaluate drug safety... hotel information, please refer to http://www.cvent.com/d/jcqhyy . (FDA has verified the Web site... within walking distance of the hotel. If you need special accommodations due to a disability, please...

  15. Detection of sentinel lymph node in breast cancer and malignant melanoma - Influence of some factors on detection success rate

    International Nuclear Information System (INIS)

    Krafta, O.; Safarcika, K.; Stepien, A.

    2004-01-01

    Full text: The aim of this study was to compare three radiopharmaceuticals for sentinel lymph node detection in breast cancer and malignant melanoma patients. We examined 100 women and 2 men with breast cancer (average age 59.3 years) and 167 patients with malignant melanoma (69 men with mean age of 58.6 years and 98 women with mean age of 53.6 years). Lymphoscintigraphy was performed in all patients after injection of the radiotracer, either of the three: NANOCIS (average particle size 100 nm), SENTISCINT (particle size 100-600 nm), and NANOCOLL (particle size under 80 nm). Dynamic scintigraphy was performed in melanoma patients while breast cancer patients were subjected to stating imaging at 1-2 and 22 hours of injection. In patients with melanoma surgery was done on the same day, to remove the primary tumor, sentinel lymph node and other nodes, wherever required. In breast cancer patients, surgery, more or less, was done on the second day of radiotracer injection. In operation theatre isosulfan blue dye and gamma probe was used to detect sentinel lymph nodes. In breast cancer patients, scintigraphy detected a total of 231 lymph nodes but failed to show sentinel lymph node in 7 patients (success rate of lymphoscintigraphy 93.1 %). Using gamma probe 158 lymph nodes were detected in 89 patients but sentinel nodes were missed in 9 patients (success rate of probe was 89.9 %). 146 lymph nodes could be visualised using blue dye in 92 patients but were missed in 12 patients (detection rate by dye was 87 %). In 2 patients sentinel lymph node could not be detected by any method. In patients with melanoma, scintigraphy showed 304 lymph nodes. However, it did not detect sentinel lymph node in 9 patients (success rate of lymphoscintigraphy was 94.6 %). 104 patients were examined by means of gamma probe and 132 lymph nodes were detected and no lymph node was found in 13 patients (success rate of probe 87.5%). Using blue dye in 140 patients, 131 nodes were found but were

  16. PENGARUH BESAR ARUS LISTRIK DENGAN MENGGUNAKAN ELEKTRODA SMAW TERHADAP KEKUATAN SAMBUNGAN LAS BUTT JOINT PADA PLAT MILD STEEL

    Directory of Open Access Journals (Sweden)

    Sarjito Jokosisworo

    2012-03-01

    Full Text Available The influence of mechanic disposition, is one of the factor influence ship strength. This influence can be test by mechanical test in welding butt joint. The result test database analysis can be conclude that very helpful to increase safety and quality butt joint. With steel specification C= 0,15%, Si= 0,24%, Mn= 0,88%,P= 0,018%, S= 0,034%. This material give a 90, 110, 125 ampere with SMAW AC electrode diameter 3,2 mm x 350 mm with V root and 600 angle In the fabrication of mild steel products, components or equipment, manufacturers employ welding as the principal joining method. Mild steel are weldable materials, and a welded joint can provide optimum corrosion resistance, strength, and fabrication economy. However, designers should recognize that any metal, including stainless steels, may undergo certain changes during welding. It is necessary, therefore, to exercise a reasonable degree of care during welding to minimize or prevent any deleterious effects that may occur, and to preserve the same degree of corrosion resistance and strength in weld zone that is an intheren part of the base metal

  17. Automatic Sub-Pixel Co-Registration of LandSat-8 OLI and Sentinel-2A MSI Images Using Phase Correlation and Machine Learning Based Mapping

    Science.gov (United States)

    Skakun, Sergii; Roger, Jean-Claude; Vermote, Eric F.; Masek, Jeffrey G.; Justice, Christopher O.

    2017-01-01

    This study investigates misregistration issues between Landsat-8/OLI and Sentinel-2A/MSI at 30 m resolution, and between multi-temporal Sentinel-2A images at 10 m resolution using a phase correlation approach and multiple transformation functions. Co-registration of 45 Landsat-8 to Sentinel-2A pairs and 37 Sentinel-2A to Sentinel-2A pairs were analyzed. Phase correlation proved to be a robust approach that allowed us to identify hundreds and thousands of control points on images acquired more than 100 days apart. Overall, misregistration of up to 1.6 pixels at 30 m resolution between Landsat-8 and Sentinel-2A images, and 1.2 pixels and 2.8 pixels at 10 m resolution between multi-temporal Sentinel-2A images from the same and different orbits, respectively, were observed. The non-linear Random Forest regression used for constructing the mapping function showed best results in terms of root mean square error (RMSE), yielding an average RMSE error of 0.07+/-0.02 pixels at 30 m resolution, and 0.09+/-0.05 and 0.15+/-0.06 pixels at 10 m resolution for the same and adjacent Sentinel-2A orbits, respectively, for multiple tiles and multiple conditions. A simpler 1st order polynomial function (affine transformation) yielded RMSE of 0.08+/-0.02 pixels at 30 m resolution and 0.12+/-0.06 (same Sentinel-2A orbits) and 0.20+/-0.09 (adjacent orbits) pixels at 10 m resolution.

  18. Sentinel nodes outside lymph node basins in patients with melanoma

    NARCIS (Netherlands)

    Roozendaal, GK; de Vries, JDH; van Poll, D; Jansen, L; Nieweg, OE; Kroon, BBR; Schraffordt Koops, H.

    Background: Lymphoscintigraphy occasionally reveals hot spots outside lymph node basins in patients with melanoma. The aim of this study was to evaluate such abnormally located hot spots. Methods: Sentinel node biopsy was studied prospectively in 379 patients with clinically localized cutaneous

  19. Breast Conserving Surgery and Sentinel Lymph Node Biopsy in Locally Advanced Breast Cancer: Single Center Experience

    Directory of Open Access Journals (Sweden)

    Atakan Sezer

    2011-06-01

    Full Text Available Objective: Patients with locally advanced breast cancer may undergo breast conserving surgery after neoadjuvant chemotherapy. The aim of the study is to evaluate the results of locally advanced breast cancer patients who underwent breast conserving surgery, axillary dissection and sentinel lymph node biopsy in a single center. Material and Methods: 12 patients with locally advanced breast cancer stage IIIA/IIIB were included in the study between 2002-2009. The patients were given anthracycline-based regimen before surgery. Patients underwent breast conserving surgery, axillary dissection, and sentinel lymph node biopsy followed by radiotherapy. Results: There were five patients in stage IIIA, six in stage IIIB, and one in stage IIIC. Patients had received 3-6 regimen of FAC/FEC. Eight had partial and four had complete response. Five positive axilla were detected. The median value of the lymph nodes was 12 (n:8-19. Five patients underwent sentinel lymph node biopsy. The biopsy has failed in one patient and the median value of dissected sentinel node was 3.5 (n:3-4. Locoregional recurrence was not observed in any patients. The mean follow-up of the patients was 29.8 months and median time was 16 (n:2-80 months.Of the 12 patients 10 are alive and 2 were deceased. Conclusion: In selected locally advanced patients, breast conserving surgery and sentinel lymph node biopsy may be applied by a multidisciplinary approach, and excellent success may be achieved in those patients as in early breast cancer patients.

  20. Radioguided sentinel node biopsy with 99mTc colloidal (Re) sulphide: Our experience

    International Nuclear Information System (INIS)

    Lago, G.; Alonso, O.; Aizen, B.; Juri, C.

    2004-01-01

    Full text: It has been demonstrated that nodal metastases from different solid tumors are not random events. Tumour spread within the regional draining basin has been shown to progress in an orderly fashion with first draining basin (sentinel node) most likely to have metastatic involvement. Thus, the sentinel node examination accurately reflects the histology of the remainder of the lymphatic basin. Sentinel node biopsy (SLB) with previous lymphatic mapping by means of radiocolloid lymphoscintraphy has been proposed by many authors as a routine method for staging the regional lymph nodes in patients with cutaneous melanoma and breast cancer. A positive SLB is found to carry high prognostic significance and identifies those patients who might benefit from early therapeutic lymph node dissection and adjuvant treatment. The aim of this retrospective study was to evaluate our experience with radioguided SLB in patients with different tumours. We studied 154 patients between 1998-2003, with clinically localized breast cancer (n=45), melanoma (n=82), cervix carcinoma (n=22) and penis carcinoma (n=5). Lymphoscintigraphy was performed 6-18 hours before surgery using a LFOV gamma camera equipped with a LEHR collimator. A dose of 111-185 MBq of 99mTc colloidal sulphide (Nanocis, Cis bio international, Gif-Sur-Yvette, France) was injected around the primary lesion (melanoma, breast cancer, and penis carcinoma) and into the four quadrants of the cervix (cervix carcinoma). All basins identified by lymphoscintigraphy were explored through incisions directed by the use of a gamma probe. Radioactivity (counts /sec) of the sentinel node(s) and the adjacent tissues was measured in-vivo and verified ex-vivo after removal. A signal to background ratio higher than 2 to 3 in-vivo and higher than 10 ex-vivo was considered significant. Blue dye mapping was performed in all cases of breast cancer but left at discretion of the surgeon for the remaining tumours. Serial sections of the

  1. Stage migration after introduction of sentinel lymph node dissection in breast cancer treatment in Denmark: a nationwide study

    DEFF Research Database (Denmark)

    Tvedskov, Tove Filtenborg; Jensen, Maj-Britt; Balslev, Eva

    2011-01-01

    To estimate the size and therapeutic consequences of stage migration after introduction of sentinel lymph node dissection (SLND) in breast cancer treatment in Denmark.......To estimate the size and therapeutic consequences of stage migration after introduction of sentinel lymph node dissection (SLND) in breast cancer treatment in Denmark....

  2. HURRICANE AND SEVERE STORM SENTINEL (HS3) FLIGHT REPORTS V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Hurricane and Severe Storm Sentinel (HS3) Flight Reports provide information about flights flown by the WB-57 and Global Hawk aircrafts during the Hurricane and...

  3. SENTINEL-2 LEVEL 1 PRODUCTS AND IMAGE PROCESSING PERFORMANCES

    Directory of Open Access Journals (Sweden)

    S. J. Baillarin

    2012-07-01

    Full Text Available In partnership with the European Commission and in the frame of the Global Monitoring for Environment and Security (GMES program, the European Space Agency (ESA is developing the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. While ensuring data continuity of former SPOT and LANDSAT multi-spectral missions, Sentinel-2 will also offer wide improvements such as a unique combination of global coverage with a wide field of view (290 km, a high revisit (5 days with two satellites, a high resolution (10 m, 20 m and 60 m and multi-spectral imagery (13 spectral bands in visible and shortwave infra-red domains. In this context, the Centre National d'Etudes Spatiales (CNES supports ESA to define the system image products and to prototype the relevant image processing techniques. This paper offers, first, an overview of the Sentinel-2 system and then, introduces the image products delivered by the ground processing: the Level-0 and Level-1A are system products which correspond to respectively raw compressed and uncompressed data (limited to internal calibration purposes, the Level-1B is the first public product: it comprises radiometric corrections (dark signal, pixels response non uniformity, crosstalk, defective pixels, restoration, and binning for 60 m bands; and an enhanced physical geometric model appended to the product but not applied, the Level-1C provides ortho-rectified top of atmosphere reflectance with a sub-pixel multi-spectral and multi-date registration; a cloud and land/water mask is associated to the product. Note that the cloud mask also provides an indication about cirrus. The ground sampling distance of Level-1C product will be 10 m, 20 m or 60 m according to the band. The final Level-1C product is tiled following a pre-defined grid of 100x100 km2, based on UTM/WGS84 reference frame

  4. SENTINEL-2 Level 1 Products and Image Processing Performances

    Science.gov (United States)

    Baillarin, S. J.; Meygret, A.; Dechoz, C.; Petrucci, B.; Lacherade, S.; Tremas, T.; Isola, C.; Martimort, P.; Spoto, F.

    2012-07-01

    In partnership with the European Commission and in the frame of the Global Monitoring for Environment and Security (GMES) program, the European Space Agency (ESA) is developing the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. While ensuring data continuity of former SPOT and LANDSAT multi-spectral missions, Sentinel-2 will also offer wide improvements such as a unique combination of global coverage with a wide field of view (290 km), a high revisit (5 days with two satellites), a high resolution (10 m, 20 m and 60 m) and multi-spectral imagery (13 spectral bands in visible and shortwave infra-red domains). In this context, the Centre National d'Etudes Spatiales (CNES) supports ESA to define the system image products and to prototype the relevant image processing techniques. This paper offers, first, an overview of the Sentinel-2 system and then, introduces the image products delivered by the ground processing: the Level-0 and Level-1A are system products which correspond to respectively raw compressed and uncompressed data (limited to internal calibration purposes), the Level-1B is the first public product: it comprises radiometric corrections (dark signal, pixels response non uniformity, crosstalk, defective pixels, restoration, and binning for 60 m bands); and an enhanced physical geometric model appended to the product but not applied, the Level-1C provides ortho-rectified top of atmosphere reflectance with a sub-pixel multi-spectral and multi-date registration; a cloud and land/water mask is associated to the product. Note that the cloud mask also provides an indication about cirrus. The ground sampling distance of Level-1C product will be 10 m, 20 m or 60 m according to the band. The final Level-1C product is tiled following a pre-defined grid of 100x100 km2, based on UTM/WGS84 reference frame. The

  5. Photo guided sentinel node mapping in breast cancer using marker free photo gamma fusion lymphoscintigraphy

    International Nuclear Information System (INIS)

    Lee, Eun Seong; Chun, In Kook; Ha, Seungn Gyun; Yoon, Hai Jeon; Jung, So Youn; Lee, See Youn; Kim, Seok Won; Lee, Eun Sook; Kim, Tae Yoon; Kim, Kwang Gi; Kim, Tae Sung; Kim, Seok Ki; Lee, Byung Il

    2012-01-01

    Photo gamma fusion lymphoscintigraphy (PGFLS) was developed by overlying a conventional planar gamma image on a photograph for the guidance of sentinel node biopsy. The feasibility and accuracy of PGFLS was assessed in breast cancer patients. A digital camera and a gamma camera were coordinated to obtain photograph and gamma images from the same angle. Using the distance to the object and calibration acquisition with a flat phantom and radioactive markers, PGFLS was performed both in phantom and in patients without fiducial markers. Marker free PGFLS was verified using flat phantom, anthropomorphic phantom with markers simulating sentinel nodes and breast cancer patients. In addition, the depth of the radioactive marker or sentinel node was calculated using two gamma images taken at right angles. The feasibility and accuracy of PGFLS were assessed in terms of mismatch errors of co registration and depth with reference to the data from SPECT/CT. The mismatch error was less than 6mm in the flat phantom image at a distance from 50 to 62cm without misalignment. In the anthropomorphic phantom study, co registration error was 0.42±0.29cm; depth error was 0.51±0.37cm, which was well correlated with the reference value on SPECT/CT (x scale: R'2'=0.99, p<0.01; y scale: R'2'=0.09, p<0.01; depth: R'2'=0.99, p<0.01). In ten patients with breast cancer referred for lympho SPECT/CT, PGFSL enabled photo guided sentinel lymph node mapping with acceptable accuracy (co-registration error, 0.47±0.24cm; depth error, 1.20±0.41cm). The results from PGFSL showed close correlation with those from SPECT/CT (x scale: R'2'=0.99, p<0.01; y scale: R'2'=0.98, p<0/01; depth: R'2'=0.77, p<0.01). The novel and convenient PGFLS technique is clinically feasible, showing acceptable accuracy and providing additional visual and quantitative information for sentinel lymph node mapping. This approach will facilitate photo guided sentinel lymph node dissection in breast cancer

  6. Gas metal arc welding of butt joint with varying gap width based on neural networks

    DEFF Research Database (Denmark)

    Christensen, Kim Hardam; Sørensen, Torben

    2005-01-01

    penetration, when the gap width is varying during the welding process. The process modeling to facilitate the mapping from joint geometry and reference weld quality to significant welding parameters, has been based on a multi-layer feed-forward network. The Levenberg-Marquardt algorithm for non-linear least......This paper describes the application of the neural network technology for gas metal arc welding (GMAW) control. A system has been developed for modeling and online adjustment of welding parameters, appropriate to guarantee a certain degree of quality in the field of butt joint welding with full...

  7. EANM-EORTC general recommendations for sentinel node diagnostics in melanoma

    DEFF Research Database (Denmark)

    Chakera, Annette H; Hesse, Birger; Burak, Zeynep

    2009-01-01

    -draining sentinel lymph nodes. If specific recommendations given cannot be based on evidence from original, scientific studies, referral is given to "general consensus" and similar expressions. The recommendations are designed to assist in the practice of referral to, performance, interpretation and reporting...

  8. The Western Environmental Technology Office (WETO), Butte, Montana, technology summary

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    This document has been prepared by the DOE Environmental Management (EM) Office of Technology Development (OTD) to highlight its research, development, demonstration, testing, and evaluation activities funded through the Western Environmental Technology Office (WETO) in Butte, Montana. Technologies and processes described have the potential to enhance DOE`s cleanup and waste management efforts, as well as improve US industry`s competitiveness in global environmental markets. WETO`s environmental technology research and testing activities focus on the recovery of useable resources from waste. Environmental technology development and commercialization activities will focus on mine cleanup, waste treatment, resource recovery, and water resource management. Since the site has no record of radioactive material use and no history of environmental contamination/remediation activities, DOE-EM can concentrate on performing developmental and demonstration activities without the demands of regulatory requirements and schedules. Thus, WETO will serve as a national resource for the development of new and innovative environmental technologies.

  9. Residual stress in a thick section high strength T-butt weld

    International Nuclear Information System (INIS)

    Pearce, S.V.; Linton, V.M.; Oliver, E.C.

    2008-01-01

    Residual stresses in a structure are generated as a result of the various fabrication and welding processes used to make the component. Being able to quantify these residual stresses is a key step in determining the continuing integrity of a structure in service. In this work, the residual stresses around a high strength, quenched and tempered steel T-butt web to curved plate weld have been measured using neutron strain scanning. The results show that the residual stresses near the weld were dominated by the welding residual stresses, while the stresses further from the weld were dominated by the bending residual stresses. The results suggest that the combination of welding-induced residual stress and significant pre-welding residual stress, as in the case of a thick bent section of plate can significantly alter the residual stress profile from that in a flat plate

  10. Evaluation of the Sentinel-3 Hydrologic Altimetry Processor prototypE (SHAPE) methods.

    Science.gov (United States)

    Benveniste, J.; Garcia-Mondéjar, A.; Bercher, N.; Fabry, P. L.; Roca, M.; Varona, E.; Fernandes, J.; Lazaro, C.; Vieira, T.; David, G.; Restano, M.; Ambrózio, A.

    2017-12-01

    Inland water scenes are highly variable, both in space and time, which leads to a much broader range of radar signatures than ocean surfaces. This applies to both LRM and "SAR" mode (SARM) altimetry. Nevertheless the enhanced along-track resolution of SARM altimeters should help improve the accuracy and precision of inland water height measurements from satellite. The SHAPE project - Sentinel-3 Hydrologic Altimetry Processor prototypE - which is funded by ESA through the Scientific Exploitation of Operational Missions Programme Element (contract number 4000115205/15/I-BG) aims at preparing for the exploitation of Sentinel-3 data over the inland water domain. The SHAPE Processor implements all of the steps necessary to derive rivers and lakes water levels and discharge from Delay-Doppler Altimetry and perform their validation against in situ data. The processor uses FBR CryoSat-2 and L1A Sentinel-3A data as input and also various ancillary data (proc. param., water masks, L2 corrections, etc.), to produce surface water levels. At a later stage, water level data are assimilated into hydrological models to derive river discharge. This poster presents the improvements obtained with the new methods and algorithms over the regions of interest (Amazon and Danube rivers, Vanern and Titicaca lakes).

  11. Combined Use of Landsat-8 and Sentinel-2 Data for Agricultural Monitoring

    Science.gov (United States)

    Skakun, S.; Roger, J. C.; Vermote, E.; Franch, B.; Becker-Reshef, I.; Justice, C. O.; Masek, J. G.

    2017-12-01

    Timely and accurate information on crop yield and production is critical to many applications within agriculture monitoring. Thanks to its coverage and temporal resolution, coarse spatial resolution satellite imagery has always been a source of valuable information for yield forecasting and assessment at national and regional scales. With availability of free images acquired by Landsat-8 and Sentinel-2 remote sensing satellites, it becomes possible to provide temporal resolution of 3-5 days, and therefore, to develop next generation agriculture products at higher spatial resolution (10-30 m). Here, we explore the combined use of Landsat-8 and Sentinel-2 data for winter crop mapping and winter wheat yield assessment at regional scale. For the former, we adapt a previously developed approach for the Moderate Resolution Imaging Spectroradiometer (MODIS) instrument at 250 m resolution that allows automatic mapping of winter crops taking into account a priori knowledge on crop calendar. For the latter, we use a generalized winter wheat yield forecasting model that is based on estimation of the peak Normalized Difference Vegetation Index (NDVI) from MODIS image time-series, and further downscaled to be applicable at 30 m resolution. We show that integration of Landsat-8 and Sentinel-2 data improves both winter crop mapping and winter wheat yield assessment.

  12. Factors with regard to computerisation of the Dutch and the Belgian national general practitioner sentinel networks: a comparative analysis.

    NARCIS (Netherlands)

    Schweikardt, C.; Casteren, V. van; Verheij, R.A.; Coppieters, Y.

    2013-01-01

    Background: A general practitioner (GP) sentinel network observes a sample of the population by supplying reports on the incidence and epidemiological characteristics of specific diseases and on procedures in primary health care. In the 1970s, the Dutch and the Belgian national GP sentinel networks

  13. Exploring the potential of Sentinel-1 data for regional scale slope instability detection using multi-temporal interferometry

    Science.gov (United States)

    Wasowski, Janusz; Bovenga, Fabio; Nutricato, Raffaele; Nitti, Davide Oscar; Chiaradia, Maria Teresa; Refice, Alberto; Pasquariello, Guido

    2016-04-01

    Launched in 2014, the European Space Agency (ESA) Sentinel-1 satellite carrying a medium resolution (20 m) C-Band Synthetic Aperture Radar (SAR) sensor holds much promise for new applications of multi-temporal interferometry (MTI) in landslide assessment. Specifically, the regularity of acquisitions, timeliness of data delivery, shorter repeat cycle (currently 12 days with Sentinel-1A sensor), and flexible incidence angle geometry, all imply better practical utility of MTI relying on Sentinel-1 with respect to MTI based on data from earlier ESA's satellite radar C-band sensors (ERS1/2, ENVISAT). Furthermore, the upcoming launch of Sentinel-1B will cut down the repeat cycle to 6 days, thereby further improving temporal coherence and quality and coverage of MTI products. Taking advantage of the Interferometric Wide (IW) Swath acquisition mode of Sentinel-1 (images covering a 250 km swath on the ground), in this work we test the potential of such data for regional scale slope instability detection through MTI. Our test area includes the landslide-prone Apennine Mountains of Southern Italy. We rely on over 30 Sentinel-1 images, most of which acquired in 2015, and MTI processing through the SPINUA algorithm (Stable Points INterferometry in Un-urbanized Areas). The potential of MTI results based on Sentinel-1 data is assessed by comparing the detected ground surface displacements with the MTI results obtained for the same test area using the C-Band data acquired by ERS1/2 and ENVISAT in 1990s and 2000s. Although the initial results are encouraging, it seems evident that longer-term (few years) acquisitions of Sentinel-1 are necessary to reliably detect some extremely slow movements, which were observed in the last two decades and are likely to be still present in peri-urban areas of many hilltop towns in the Apennine Mts. The MTI results obtained from Sentinel-1 data are also locally compared with the MTI outcomes based on the high resolution (3 m) TerraSAR-X imagery

  14. Predictors of non-sentinel lymph node metastasis in breast cancer patients with positive sentinel lymph node (Pilot study)

    International Nuclear Information System (INIS)

    Eldweny, H.; Alkhaldy, Kh.; Alsaleh, N.; Abdulsamad, M.; Abbas, A.; Hamad, A.; Mounib, Sh.; Essam, T.; Kukawski, P.; Bobin, J.; Oteifa, M.; Amangoono, H.; Abulhoda, F.; Usmani, Sh.; Elbasmy, A.

    2012-01-01

    Background: Sentinel Lymph Node Biopsy [SLNB) procedure was found to be an accurate method of staging the axilla in patients with early stage breast cancer. The standard of care for breast cancer patients with positive SLN metastasis includes complete Axillary Lymph Node Dissection (ALND). Haw ever, in 40-70% of patients, the SLN the only involved axillary node. Factors predicting non SLW metastasis should be identified in order to define subgroups of patient with positive SLN in whom the axilla may be staged by SLNB done. Objective: To identify the factors predicting metastatic involvement of the non-SLNs in breast cancer patients having SLN metastases. Patients and Methods: Data were collected and analyzed from 80 patients with early stage invasive breast cancer (T1, T2, N0, M0) who underwent SLNB at the surgical Oncology Department, Kuwait Cancel control Center (KCCC) between November 2004 and February 2009. SLNB was perfomed using a combined technique (radioactive colloid, and blue dye) in the majority of cases in some cases, only one technique was used. Complete ALND was performed in the case of failure of SLN identification and in patients with positive SLN. Multiple variables (patient, tumor and of SLN identification and in patients with positive SLN. Multiple variables (patient, tumor, and SLN characteristics) with tested as possible predictors of non sentinel lymph node metastasis. Results: The mean age of patients at diagnosis was 46.6 years. The median tumor size was 2 cm. The SLN identification rate was 96.2% (77 out of 80 patients). The SLN was positive in 24 patients(31%), and half of these showed evidence of capsular invasion. The median number of SLNs removed was two. The median number positive SLNs was one. The incidence of non-SLN metatasis associated with positive SLN was 50% (12 out of 24 patients). lymphovascular invasion was found to be the only factor associated with non-SLN metastases. In addition, two trends were observed, though they did

  15. New Spectral Index for Detecting Wheat Yellow Rust Using Sentinel-2 Multispectral Imagery

    Directory of Open Access Journals (Sweden)

    Qiong Zheng

    2018-03-01

    Full Text Available Yellow rust is one of the most destructive diseases for winter wheat and has led to a significant decrease in winter wheat quality and yield. Identifying and monitoring yellow rust is of great importance for guiding agricultural production over large areas. Compared with traditional crop disease discrimination methods, remote sensing technology has proven to be a useful tool for accomplishing such a task at large scale. This study explores the potential of the Sentinel-2 Multispectral Instrument (MSI, a newly launched satellite with refined spatial resolution and three red-edge bands, for discriminating between yellow rust infection severities (i.e., healthy, slight, and severe in winter wheat. The corresponding simulative multispectral bands for the Sentinel-2 sensor were calculated by the sensor’s relative spectral response (RSR function based on the in situ hyperspectral data acquired at the canopy level. Three Sentinel-2 spectral bands, including B4 (Red, B5 (Re1, and B7 (Re3, were found to be sensitive bands using the random forest (RF method. A new multispectral index, the Red Edge Disease Stress Index (REDSI, which consists of these sensitive bands, was proposed to detect yellow rust infection at different severity levels. The overall identification accuracy for REDSI was 84.1% and the kappa coefficient was 0.76. Moreover, REDSI performed better than other commonly used disease spectral indexes for yellow rust discrimination at the canopy scale. The optimal threshold method was adopted for mapping yellow rust infection at regional scales based on realistic Sentinel-2 multispectral image data to further assess REDSI’s ability for yellow rust detection. The overall accuracy was 85.2% and kappa coefficient was 0.67, which was found through validation against a set of field survey data. This study suggests that the Sentinel-2 MSI has the potential for yellow rust discrimination, and the newly proposed REDSI has great robustness and

  16. New Spectral Index for Detecting Wheat Yellow Rust Using Sentinel-2 Multispectral Imagery.

    Science.gov (United States)

    Zheng, Qiong; Huang, Wenjiang; Cui, Ximin; Shi, Yue; Liu, Linyi

    2018-03-15

    Yellow rust is one of the most destructive diseases for winter wheat and has led to a significant decrease in winter wheat quality and yield. Identifying and monitoring yellow rust is of great importance for guiding agricultural production over large areas. Compared with traditional crop disease discrimination methods, remote sensing technology has proven to be a useful tool for accomplishing such a task at large scale. This study explores the potential of the Sentinel-2 Multispectral Instrument (MSI), a newly launched satellite with refined spatial resolution and three red-edge bands, for discriminating between yellow rust infection severities (i.e., healthy, slight, and severe) in winter wheat. The corresponding simulative multispectral bands for the Sentinel-2 sensor were calculated by the sensor's relative spectral response (RSR) function based on the in situ hyperspectral data acquired at the canopy level. Three Sentinel-2 spectral bands, including B4 (Red), B5 (Re1), and B7 (Re3), were found to be sensitive bands using the random forest (RF) method. A new multispectral index, the Red Edge Disease Stress Index (REDSI), which consists of these sensitive bands, was proposed to detect yellow rust infection at different severity levels. The overall identification accuracy for REDSI was 84.1% and the kappa coefficient was 0.76. Moreover, REDSI performed better than other commonly used disease spectral indexes for yellow rust discrimination at the canopy scale. The optimal threshold method was adopted for mapping yellow rust infection at regional scales based on realistic Sentinel-2 multispectral image data to further assess REDSI's ability for yellow rust detection. The overall accuracy was 85.2% and kappa coefficient was 0.67, which was found through validation against a set of field survey data. This study suggests that the Sentinel-2 MSI has the potential for yellow rust discrimination, and the newly proposed REDSI has great robustness and generalized ability

  17. HIV prevalence in South Sudan: data from the ANC sentinel ...

    African Journals Online (AJOL)

    data, triangulated with data from other sources that will achieve informed consensus about population prevalence. Methodology selection of sample. Sentinel surveillance was conducted among pregnant women aged 15-49 attending ANC. Pregnant women were selected as a proxy for the general population and because ...

  18. Sentinel node biopsy and concomitant probe-guided tumor excision of nonpalpable breast cancer.

    Science.gov (United States)

    van Rijk, Maartje C; Tanis, Pieter J; Nieweg, Omgo E; Loo, Claudette E; Olmos, Renato A Valdés; Oldenburg, Hester S A; Rutgers, Emiel J Th; Hoefnagel, Cornelis A; Kroon, Bin B R

    2007-02-01

    Preliminary data have shown encouraging results of a single intratumoral radiopharmaceutical injection that enables both sentinel node biopsy and probe-guided excision of the primary tumor in patients with nonpalpable breast cancer. The aim of the study was to evaluate this approach in a large group of patients. Lymphoscintigraphy was performed in 368 patients with nonpalpable breast cancer after intratumoral injection of (99m)Tc-nanocolloid (.2 mL, 123 MBq, 3.3 mCi) guided by ultrasound or stereotaxis. The sentinel node was pursued with the aid of vital blue dye (1.0 mL, intratumoral) and a gamma ray detection probe. In case of breast-conserving surgery, the probe was used to guide the excision. At least one sentinel node could be identified intraoperatively in 357 patients (97%), of whom 69 had involved nodes (19%). Age over 60 years was associated with less frequent nonaxillary lymphatic drainage and absence of internal mammary chain dissemination. Tumor-free margins were obtained in 262 (89%) of the 293 patients who underwent segmental excision. Re-excision of the primary tumor bed was performed in six patients (2%). During a median follow-up of 22 months, one breast recurrence and one axillary recurrence were observed. Lymphatic mapping and probe-guided tumor excision of nonpalpable breast cancer by intralesional administration of a single dose of (99m)Tc-nanocolloid and blue dye resulted in 97% identification of the sentinel node and in tumor-free margins in 89% of the patients who underwent breast-conserving surgery. Longer follow-up is needed to substantiate the accuracy and safety of this technique.

  19. Validation of Land Surface Temperature from Sentinel-3

    Science.gov (United States)

    Ghent, D.

    2017-12-01

    One of the main objectives of the Sentinel-3 mission is to measure sea- and land-surface temperature with high-end accuracy and reliability in support of environmental and climate monitoring in an operational context. Calibration and validation are thus key criteria for operationalization within the framework of the Sentinel-3 Mission Performance Centre (S3MPC). Land surface temperature (LST) has a long heritage of satellite observations which have facilitated our understanding of land surface and climate change processes, such as desertification, urbanization, deforestation and land/atmosphere coupling. These observations have been acquired from a variety of satellite instruments on platforms in both low-earth orbit and in geostationary orbit. Retrieval accuracy can be a challenge though; surface emissivities can be highly variable owing to the heterogeneity of the land, and atmospheric effects caused by the presence of aerosols and by water vapour absorption can give a bias to the underlying LST. As such, a rigorous validation is critical in order to assess the quality of the data and the associated uncertainties. Validation of the level-2 SL_2_LST product, which became freely available on an operational basis from 5th July 2017 builds on an established validation protocol for satellite-based LST. This set of guidelines provides a standardized framework for structuring LST validation activities. The protocol introduces a four-pronged approach which can be summarised thus: i) in situ validation where ground-based observations are available; ii) radiance-based validation over sites that are homogeneous in emissivity; iii) intercomparison with retrievals from other satellite sensors; iv) time-series analysis to identify artefacts on an interannual time-scale. This multi-dimensional approach is a necessary requirement for assessing the performance of the LST algorithm for the Sea and Land Surface Temperature Radiometer (SLSTR) which is designed around biome

  20. Building a Data Set over 12 Globally Distributed Sites to Support the Development of Agriculture Monitoring Applications with Sentinel-2

    Directory of Open Access Journals (Sweden)

    Sophie Bontemps

    2015-12-01

    Full Text Available Developing better agricultural monitoring capabilities based on Earth Observation data is critical for strengthening food production information and market transparency. The Sentinel-2 mission has the optimal capacity for regional to global agriculture monitoring in terms of resolution (10–20 meter, revisit frequency (five days and coverage (global. In this context, the European Space Agency launched in 2014 the “Sentinel­2 for Agriculture” project, which aims to prepare the exploitation of Sentinel-2 data for agriculture monitoring through the development of open source processing chains for relevant products. The project generated an unprecedented data set, made of “Sentinel-2 like” time series and in situ data acquired in 2013 over 12 globally distributed sites. Earth Observation time series were mostly built on the SPOT4 (Take 5 data set, which was specifically designed to simulate Sentinel-2. They also included Landsat 8 and RapidEye imagery as complementary data sources. Images were pre-processed to Level 2A and the quality of the resulting time series was assessed. In situ data about cropland, crop type and biophysical variables were shared by site managers, most of them belonging to the “Joint Experiment for Crop Assessment and Monitoring” network. This data set allowed testing and comparing across sites the methodologies that will be at the core of the future “Sentinel­2 for Agriculture” system.

  1. Validation of Hotspots Detected by Satellites in Sentinel Asia

    Science.gov (United States)

    Kaku, K.; Kushida, K.; Fukuda, M.

    2008-12-01

    The Sentinel Asia (SA) initiative is a collaboration between space agencies and disaster management agencies, applying remote sensing and Web-GIS technologies to assist disaster management in the Asia- Pacific region. It aims to: "EImprove safety in society by ICT and space technology "EImprove speed and accuracy of disaster preparedness and early warning "EMinimize the number of victims and social/economic losses. SA is a voluntary initiative led by the Asia-Pacific Regional Space Agency Forum (APRSAF) to share disaster information in near-real-time across the Asia-Pacific region. Wildfire is a major and recurring phenomenon that has a serious impact on property and human health, affecting many countries in the Asia region. Compared to other disasters in the area, it does not necessarily cause many immediate fatalities. However, it causes serious impact on property and human health due to smoke. Furthermore, its effects are of great relevance both at a regional and global level, and accordingly bear substantial influence on global warming. Responding to requirements from Asian countries, under Sentinel Asia a dedicated Wildfire Working Group (WG) has been established to apply remote sensing technology to the management of wildfire. Having accurate information on the location and intensity of the fires, and subsequent control of wildfire, are therefore very important and urgent tasks across the region. SA primarily addresses the issue of near-real-time information distribution on wildfires in the region. Concerning hotspot data obtained by satellites, it is essential to validate and improve its accuracy. In the framework of Sentinel Asia Wildfire WG, various approaches to hotspot detection, including MOD14 algorithm for MODIS hotspots, were studied, and their validations were carried out, comparing them with active fires extracted from satellite imagery and ground truth data in Chiengmai, Thailand and in Kalimantan, Indonesia.

  2. Harmonized Landsat/Sentinel-2 Reflectance Products for Land Monitoring

    Science.gov (United States)

    Masek, J. G.; Ju, J.; Claverie, M.; Vermote, E.; Dungan, J. L.; Roger, J. C.; Skakun, S.; Justice, C. O.

    2017-12-01

    Many land applications require more frequent observations than can be obtained from a single "Landsat class" sensor. Agricultural monitoring, inland water quality assessment, stand-scale phenology, and numerous other applications all require near-daily imagery at better than 1ha resolution. Thus the land science community has begun expressing a desire for a "30-meter MODIS" global monitoring capability. One cost-effective way to achieve this goal is via merging data from multiple, international observatories into a single virtual constellation. The Harmonized Landsat/Sentinel-2 (HLS) project has been working to generate a seamless surface reflectance product by combining observations from USGS/NASA Landsat-8 and ESA Sentinel-2. Harmonization in this context requires a series of radiometric and geometric transforms to create a single surface reflectance time series agnostic to sensor origin. Radiometric corrections include a common atmospheric correction using the Landsat-8 LaSRC/6S approach, a simple BRDF adjustment to constant solar and nadir view angle, and spectral bandpass adjustments to fit the Landsat-8 OLI reference. Data are then resampled to a consistent 30m UTM grid, using the Sentinel-2 global tile system. Cloud and shadow masking are also implemented. Quality assurance (QA) involves comparison of the output 30m HLS products with near-simultaneous MODIS nadir-adjusted observations. Prototoype HLS products have been processed for 7% of the global land area using the NASA Earth Exchange (NEX) compute environment at NASA Ames, and can be downloaded from the HLS web site (https://hls.gsfc.nasa.gov). A wall-to-wall North America data set is being prepared for 2018.This talk will review the objectives and status of the HLS project, and illustrate applications of high-density optical time series data for agriculture and ecology. We also discuss lessons learned from HLS in the general context of implementing virtual constellations.

  3. Sentinel model for influenza A virus monitoring in free-grazing ducks in Thailand.

    Science.gov (United States)

    Boonyapisitsopa, Supanat; Chaiyawong, Supassama; Nonthabenjawan, Nutthawan; Jairak, Waleemas; Prakairungnamthip, Duangduean; Bunpapong, Napawan; Amonsin, Alongkorn

    2016-01-01

    Influenza A virus (IAV) can cause influenza in birds and mammals. In Thailand, free-grazing ducks are known IAV reservoirs and can spread viruses through frequent movements in habitats they share with wild birds. In this study, the sentinel model for IAV monitoring was conducted over 4 months in two free-grazing duck flocks. IAV subtypes H4N6 (n=1) and H3N8 (n=5) were isolated from sentinel ducks at the ages of 13 and 15 weeks. Clinical signs of depression and ocular discharge were observed in the infected ducks. Phylogenetic analysis and genetic characterization of the isolated IAVs indicated that all Thai IAVs were clustered in the Eurasian lineage and pose low pathogenic avian influenza characteristics. Serological analysis found that antibodies against IAVs could be detected in the ducks since 9-weeks-old. In summary, our results indicate that the sentinel model can be used for IAV monitoring in free-grazing duck flocks. Since free-grazing ducks are potential reservoirs and transmitters of IAVs, routine IAV surveillance in free-grazing duck flocks can be beneficial for influenza prevention and control strategies. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Contribution of the sentinel lymph node detection in oral cavity and oropharynx cancer

    International Nuclear Information System (INIS)

    Comte, F.; Barge, M.L.; Chevalier, J.; Rossi, M.; Zanca, M.; Alovisetti, C.; Garrel, R.; Guerrier, B.; Costes, V.

    2004-01-01

    The histopathological features of lymph nodes removal in head and neck cancer bring major prognostic information. Molecular biology or immuno histological techniques allow a far better detection sensitivity while underlining micrometastases. However, due to the great number of removed lymph nodes, an exhaustive histological analysis is impossible and an efficient targeting is desirable. The aim of this study was to establish the feasibility of the gamma probe directed biopsy of the sentinel lymph node in oral and oropharyngeal carcinoma. Up to date, 13 patients with oral and oropharyngeal cancers (T1pNO) were included. The sentinel lymph node was detected during surgery and selectively resected before traditional neck lymph dissection. The sentinel lymph node (SLN) was detected in 92 % of patients. In one case, the immunohistochemical analysis of the SLN showed a micro-metastatic involvement while the classical histological analysis remained negative.The preliminary analysis of our study attests the SLN radio-localization efficiency in head and neck cancers and allows the systematic detection of micro-metastatic involvement. The pursuit of this study will continue to confirm these results from a larger population and to precise the prognostic value of the micro-metastatic stage. (author)

  5. Characterization of heterogeneous reservoirs: sentinels method and quantification of uncertainties; Caracterisation des reservoirs heterogenes: methode des sentinelles et quantification des incertitudes

    Energy Technology Data Exchange (ETDEWEB)

    Mezghani, M.

    1999-02-11

    The aim of this thesis is to propose a new inversion method to allow both an improved reservoir characterization and a management of uncertainties. In this approach, the identification of the permeability distribution is conducted using the sentinel method in order to match the pressure data. This approach, based on optimal control theory, can be seen as an alternative of least-squares method. Here, we prove the existence of exact sentinels under regularity hypothesis. From a numerical point of view, we consider regularized sentinels. We suggest a novel approach to update the penalization coefficient in order to improve numerical robustness. Moreover, the flexibility of the sentinel method enables to develop a way to treat noisy pressure data. To deal with geostatistical modelling of permeability distribution, we propose to link the pilot point method with sentinels to reach the identification of permeability. We particularly focus on the optimal location of pilot points. Finally, we present an original method, based on adjoint state computations, to quantify the dynamic data contribution to the characterisation of a calibrated geostatistical model. (author) 67 refs.

  6. Red Fox as Sentinel for Blastomyces dermatitidis, Ontario, Canada.

    Science.gov (United States)

    Nemeth, Nicole M; Campbell, G Douglas; Oesterle, Paul T; Shirose, Lenny; McEwen, Beverly; Jardine, Claire M

    2016-07-01

    Blastomyces dermatitidis, a fungus that can cause fatal infection in humans and other mammals, is not readily recoverable from soil, its environmental reservoir. Because of the red fox's widespread distribution, susceptibility to B. dermatitidis, close association with soil, and well-defined home ranges, this animal has potential utility as a sentinel for this fungus.

  7. Intra-operative lymphatic mapping with Dextran Tc-99m and blue dye for sentinel node detection in patients with primary vulvar malignancies

    International Nuclear Information System (INIS)

    Morales, R.E.; Aguilar, C.R.; Cano, R.A.; Saavedra, P.; Santos, C.

    2004-01-01

    Full text: The purpose of this study was to determine the feasibility of sentinel lymph node detection using preoperative lymphoscintigraphy and intra-operative lymphatic mapping in patients with primary vulvar malignancies. Nine patients (29-84 years old) with primary vulvar malignancy were scheduled for sentinel node detection. Two patients had malignant melanoma of the vulva and seven had squamous cell carcinomas. Eight patients did not have a previous surgery of the primary tumour nor of the lymph nodes, one had an aspiration biopsy. Three hours before surgery 1-5 mCi of Tc-99m Dextran was injected intradermally in four points in the skin junction adjacent to the vulvar lesions. Static lymphoscintigraphy was performed using a planar GE gamma camera with a multipurpose low energy collimator, in anterior and lateral views. Images were displayed on a personal computer, through a Portable Imaging Processing software (PIP). In two cases a Siemens ECAM SPECT camera was used, due to necessity of having high-resolution images. Patten blue dye was injected in the junction between the skin and vulvar tumor, in the surgery room, after anaesthesia induction. Agamma probe (Navigator Gamma Guidance System) was used to detect the sentinel node. The activity in the sentinel node was measured in each case, before and after resection. Activity in the remaining tissue was also measured. Nodes were adequately placed in plastic bags and sent to pathology for H-E staining. Non-sentinel nodes were also resected and sent for pathology, except in two cases. Sentinel nodes (SN) were visualised on lymphoscintigraphy 1 to 5 minutes after injection of Tc-99m Dextran. In malignant melanoma drainage to the sentinel node was faster than for other tumours. There were five cases who had bilateral SN in inguinal regions, in other three cases, two SN were located on the same side, two in the inguinal region. In all cases the SN was identified corroborating to the skin mark and with enough

  8. Interest of the technical detection of the sentinel node applied to uterine cancers: about three cases

    International Nuclear Information System (INIS)

    Ech charraq, I.; Ben Rais, N.; Ech charra, I.; Albertini, A.F.

    2009-01-01

    Introduction The sentinel node technique (S.N.) was proposed in cervical cancers in order to optimise the diagnosis of metastases and the lymphatic micrometastases in the early stages while avoiding useless wide clearings out. The identification of this node is done by injection of a dye and/or a radioactive colloid and its ablation for pathological examination. Patients and methods We report the case of three patients followed for a uterine cancer having benefited from a lymphoscintigraphy before surgery. During the surgical procedure, the detection of the sentinel node was carried out after cervical injection of blue dye and using a gamma detection probe. Results The lymphoscintigraphy was positive for two cases with a positive detection for the three cases during the operation. The pathological study revealed a node metastasis for one case. The technical of the sentinel node applied to uterine cancers appears realizable essentially for uterine cancers of early stage (I). However the risk of false negative can be observed in advanced cancer (III), as it is the case of our patient having a negative lymphoscintigraphy. Conclusion The nuclear medicine is important in the detection of the sentinel node of various cancers, uterine cancer included, thus allowing an appropriate cardiologic management. (authors)

  9. Sentinel lymph nodes detection with an imaging system using Patent Blue V dye as fluorescent tracer

    Science.gov (United States)

    Tellier, F.; Steibel, J.; Chabrier, R.; Rodier, J. F.; Pourroy, G.; Poulet, P.

    2013-03-01

    Sentinel lymph node biopsy is the gold standard to detect metastatic invasion from primary breast cancer. This method can help patients avoid full axillary chain dissection, thereby decreasing the risk of morbidity. We propose an alternative to the traditional isotopic method, to detect and map the sentinel lymph nodes. Indeed, Patent Blue V is the most widely used dye in clinical routine for the visual detection of sentinel lymph nodes. A Recent study has shown the possibility of increasing the fluorescence quantum yield of Patent Blue V, when it is bound to human serum albumin. In this study we present a preclinical fluorescence imaging system to detect sentinel lymph nodes labeled with this fluorescent tracer. The setup is composed of a black and white CCD camera and two laser sources. One excitation source with a laser emitting at 635 nm and a second laser at 785 nm to illuminate the region of interest. The prototype is operated via a laptop. Preliminary experiments permitted to determine the device sensitivity in the μmol.L-1 range as regards the detection of PBV fluorescence signals. We also present a preclinical evaluation performed on Lewis rats, during which the fluorescence imaging setup detected the accumulation and fixation of the fluorescent dye on different nodes through the skin.

  10. Recreational Use and Value of Water at Elephant Butte and Navajo Reservoirs. New Mexico State University Agricultural Experiment Station Bulletin 535.

    Science.gov (United States)

    Coppedge, Robert O.; Gray, James R.

    This document is a descriptive study of the recreational use and the value of water at Elephant Butte and Navajo Reservoirs. Previous research studies, as well as the study areas and recreational characteristics and procedures of investigation used in this study (sampling and data collection, data organization, analysis) are described. Discussions…

  11. Treefall Gap Mapping Using Sentinel-2 Images

    Directory of Open Access Journals (Sweden)

    Iván Barton

    2017-11-01

    Full Text Available Proper knowledge about resources in forest management is fundamental. One of the most important parameters of forests is their size or spatial extension. By determining the area of treefall gaps inside the compartments, a more accurate yield can be calculated and the scheduling of forestry operations could be planned better. Several field- and remote sensing-based approaches are in use for mapping but they provide only static measurements at high cost. The Earth Observation satellite mission Sentinel-2 was put in orbit as part of the Copernicus programme. With the 10-m resolution bands, it is possible to observe small-scale forestry operations like treefall gaps. The spatial extension of these gaps is often less than 200 m2, thus their detection can only be done on sub-pixel level. Due to the higher temporal resolution of Sentinel-2, multiple observations are available in a year; therefore, a time series evaluation is possible. The modelling of illumination can increase the accuracy of classification in mountainous areas. The method was tested on three deciduous forest sites in the Börzsöny Mountains in Hungary. The area evaluation produced less than 10% overestimation with the best possible solutions on the sites. The presented work shows a low-cost method for mapping treefall gaps which delivers annual information about the gap area in a deciduous forest.

  12. Validating MODIS and Sentinel-2 NDVI Products at a Temperate Deciduous Forest Site Using Two Independent Ground-Based Sensors.

    Science.gov (United States)

    Lange, Maximilian; Dechant, Benjamin; Rebmann, Corinna; Vohland, Michael; Cuntz, Matthias; Doktor, Daniel

    2017-08-11

    Quantifying the accuracy of remote sensing products is a timely endeavor given the rapid increase in Earth observation missions. A validation site for Sentinel-2 products was hence established in central Germany. Automatic multispectral and hyperspectral sensor systems were installed in parallel with an existing eddy covariance flux tower, providing spectral information of the vegetation present at high temporal resolution. Normalized Difference Vegetation Index (NDVI) values from ground-based hyperspectral and multispectral sensors were compared with NDVI products derived from Sentinel-2A and Moderate-resolution Imaging Spectroradiometer (MODIS). The influence of different spatial and temporal resolutions was assessed. High correlations and similar phenological patterns between in situ and satellite-based NDVI time series demonstrated the reliability of satellite-based phenological metrics. Sentinel-2-derived metrics showed better agreement with in situ measurements than MODIS-derived metrics. Dynamic filtering with the best index slope extraction algorithm was nevertheless beneficial for Sentinel-2 NDVI time series despite the availability of quality information from the atmospheric correction procedure.

  13. From ASCAT to Sentinel-1: Soil Moisture Monitoring using European C-Band Radars

    Science.gov (United States)

    Wagner, Wolfgang; Bauer-Marschallinger, Bernhard; Hochstöger, Simon

    2016-04-01

    The Advanced Scatterometer (ASCAT) is a C-Band radar instrument flown on board of the series of three METOP satellites. Albeit not operating in one of the more favorable longer wavelength ranges (S, L or P-band) as the dedicated Soil Moisture and Ocean Salinity (SMOS) and Soil Moisture Active Passive (SMAP) missions, it is one of main microwave sensors used for monitoring of soil moisture on a global scale. Its attractiveness for soil moisture monitoring applications stems from its operational status, high radiometric accuracy and stability, short revisit time, multiple viewing directions and long heritage (Wagner et al. 2013). From an application perspective, its main limitation is its spatial resolution of about 25 km, which does not allow resolving soil moisture patterns driven by smaller-scale hydrometeorological processes (e.g. convective precipitation, runoff patterns, etc.) that are themselves related to highly variable land surface characteristics (soil characteristics, topography, vegetation cover, etc.). Fortunately, the technique of aperture synthesis allows to significantly improve the spatial resolution of spaceborne radar instruments up to the meter scale. Yet, past Synthetic Aperture Radar (SAR) missions had not yet been designed to achieve a short revisit time required for soil moisture monitoring. This has only changed recently with the development and launch of SMAP (Entekhabi et al. 2010) and Sentinel-1 (Hornacek et al. 2012). Unfortunately, the SMAP radar failed only after a few months of operations, which leaves Sentinel-1 as the only currently operational SAR mission capable of delivering high-resolution radar observations with a revisit time of about three days for Europe, about weekly for most crop growing regions worldwide, and about bi-weekly to monthly over the rest of the land surface area. Like ASCAT, Sentinel-1 acquires C-band backscatter data in VV polarization over land. Therefore, for the interpretation of both ASCAT and Sentinel-1

  14. Axillary web syndrome following sentinel node biopsy for breast cancer.

    Science.gov (United States)

    Nieves Maldonado, S M; Pubul Núñez, V; Argibay Vázquez, S; Macías Cortiñas, M; Ruibal Morell, Á

    2016-01-01

    A 49 year-old woman diagnosed with infiltrating lobular breast carcinoma, underwent a right mastectomy and sentinel node biopsy (SLNB). The resected sentinel lymph nodes were negative for malignancy, with an axillary lymphadenectomy not being performed. In the early post-operative period, the patient reported an axillary skin tension sensation, associated with a painful palpable cord. These are typical manifestations of axillary web syndrome (AWS), a poorly known axillary surgery complication, from both invasive and conservative interventions. By presenting this case we want to focus the attention on a pathological condition, for which its incidence may be underestimated by not including it in SLNB studies. It is important for nuclear medicine physicians to be aware of AWS as a more common complication than infection, seroma, or lymphoedema, and to discuss this possible event with the patient who is consenting to the procedure. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  15. Selective Sentinel Lymphadenectomy for Breast Cancer in the United States

    Directory of Open Access Journals (Sweden)

    Stanley P.L. Leong

    2004-10-01

    Full Text Available Lymph node status is the most reliable prognostic indicator for breast cancer patients. Sentinel lymph nodes (SLNs are the first draining lymph nodes for metastatic breast cancer to spread from the primary site. Although the therapeutic role of selective sentinel lymphadenectomy (SSL in breast cancer has not been determined, the practical significance is that it is being used as a staging procedure, so that a negative SLN can spare a patient more extensive axillary lymph node dissection (ALND with its associated morbidity. If the SLN is negative, the negative predictive value of the remaining nodal basin for breast cancer exceeds 95%. SSL selects out one or a few SLNs and permits more extensive study of the nodes by the pathologist. Such extensive examination would not be practical for the many nodes yielded by a standard ALND. SSL is rapidly evolving into a standard approach for staging primary breast cancer in the United States, without the maturation of results from clinical trials.

  16. Sentinel 2: implementation of the means and methods for the CAL/VAL commissioning phase

    Science.gov (United States)

    Trémas, Thierry L.; Déchoz, Cécile; Lacherade, Sophie; Nosavan, Julien; Petrucci, Beatrice; Martimort, P.; Isola, Claudia

    2013-10-01

    In partnership with the European Commission and in the frame of the Copernicus program, the European Space Agency (ESA) is developing the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. Sentinel-2 will offer a unique combination of global coverage with a wide field of view (290km), a high revisit (5 days with two satellites), a high resolution (10m, 20m and 60m) and multi-spectral imagery (13 spectral bands in visible and shortwave infra-red domains). The first satellite is planned to be launched in late 2014. In this context, the Centre National d'Etudes Spatiales (CNES) supports ESA to insure the cal/val commissioning phase. This paper provides first, an overview of the Sentinel-2 system and the image products delivered by the ground processing. Then the paper will present the ground segment, presently under preparation at CNES, and the various devices that compose it : the GPP in charge of producing the level 1 files, the "radiometric unit" that processes sensitivity parameters, the "geometric unit" in charge of fitting the images on a reference map, MACCS that will produce Level 2A files (computing reflectances at the Bottom of Atmosphere) and the TEC-S2 that will coordinate all the previous software and drive a database in which will be gather the incoming Level 0 files and the processed Level 1 files.

  17. Land use classification from Sentinel-2 imagery

    OpenAIRE

    Borràs, J.; Delegido, J.; Pezzola, A.; Pereira, M.; Morassi, G.; Camps-Valls, G.

    2017-01-01

    [EN] Sentinel-2 (S2), a new ESA satellite for Earth observation, accounts with 13 bands which provide high-quality radiometric images with an excellent spatial resolution (10 and 20 m) ideal for classification purposes. In this paper, two objectives have been addressed: to determine the best classification method for S2, and to quantify its improve-ment with respect to the SPOT operational mission. To do so, four classifiers (LDA, RF, Decision Trees, K-NN) have been selected and applied to tw...

  18. Characterising and improving the performance of the Sentinel-3 SRAL altimeter: A Report from SCOOP, SHAPE & SPICE Projects

    Science.gov (United States)

    Restano, Marco; Ambrózio, Américo; Cotton, David; Scoop Team; Fabry, Pierre; Shape Team; McMillan, Malcolm; Spice Team; Benveniste, Jérôme

    2017-04-01

    Under the ESA Scientific Exploitation of Operational Missions (SEOM) Programme, 3 Projects are currently underway to accurately characterise and improve the performance of the Sentinel-3 SRAL SAR mode altimeter. They are: 1) SCOOP (SAR Altimetry Coastal & Open Ocean Performance Exploitation and Roadmap Study) for Coastal and Open Ocean; 2) SHAPE (Sentinel-3 Hydrologic Altimetry PrototypE) for Inland Water; 3) SPICE (Sentinel-3 Performance improvement for ICE sheets) for Ice Sheets. As projects started before the launch of Sentinel-3 (a full SAR mission), calibrated Cryosat-2 data have been used as input to a processor replicating the Sentinel-3 baseline processing. For the SCOOP project, a first test dataset has been released to end users including data from 10 regions of interest. The successful SAMOSA retracker, adopted in the previous CP4O Project (CryoSat Plus for Oceans), has been readapted to re-track Sentinel-3 waveforms. An improved version of SAMOSA will be released at the end of the project. The SHAPE project is working towards the design and assessment of alternative/innovative techniques not implemented in the Sentinel-3 ground segment (performing no Inland Water dedicated processing). Both rivers and lakes will be studied. Amazon, Brahmaputra and Danube have been selected as rivers, whereas Titicaca and Vanern have been chosen as lakes. The study will include the assimilation of output products into hydrological models for all regions of interest. A final dataset will be provided to end users. The SPICE project is addressing four high level objectives: 1) Assess and improve the Delay-Doppler altimeter processing for ice sheets. 2) Assess and develop SAR waveform retrackers for ice sheets. 3) Evaluate the performance of SAR altimetry relative to conventional pulse limited altimetry. 4) Assess the impact on SAR altimeter measurements of radar wave interaction with the snowpack. Dataset used for validation include ICESat and IceBridge products. Vostok

  19. TEM analysis of a friction stir-welded butt joint of Al-Si-Mg alloys

    International Nuclear Information System (INIS)

    Cabibbo, M.; Meccia, E.; Evangelista, E.

    2003-01-01

    The microstructure evolution of a joint of Al-Si-Mg alloys A6056-T4 and A6056-T6 has been characterized by transmission electron microscopy (TEM). Metallurgical investigations, hardness and mechanical tests were also performed to correlate the TEM investigations to the mechanical properties of the produced friction stir-welded butt joint. After friction stir-welding thermal treatment has been carried out at 530 deg. C followed by ageing at 160 deg. C (T6). The base material (T4) and the heat-treated one (T6) were put in comparison showing a remarkable ductility reduction of the joint after T6 treatment

  20. A novel butt-joint scheme for the preparation of electro-absorptive lasers

    International Nuclear Information System (INIS)

    Cheng Yuanbing; Pan Jiaoqing; Zhou Fan; Feng Wen; Wang Baojun; Zhu Hongliang; Zhao Lingjuan; Wang Wei

    2008-01-01

    A 1.55 μm InGaAsP/InGaAsP multiple-quantum-well electro-absorption modulator (EAM) monolithically integrated with a distributed feedback laser (DFB) diode has been realized based on a novel butt-joint scheme by ultra-low metal-organic vapour phase epitaxy for the first time. The threshold current of 25 mA and an extinction ratio of more than 30 dB are obtained by using the novel structure. The beam divergence angles at the horizontal and vertical directions are as small as 19.3 deg. x 13 deg., respectively, without a spot-size converter by undercutting the InGaAsP active region. The capacitance of the ridge waveguide device with a deep mesa buried by polyimide was reduced down to 0.30 pF

  1. Assessment of undiscovered oil and gas resources in the Uteland Butte Member of the Eocene Green River Formation, Uinta Basin, Utah

    Science.gov (United States)

    Johnson, Ronald C.; Birdwell, Justin E.; Mercier, Tracey J.; Brownfield, Michael E.; Charpentier, Ronald R.; Klett, Timothy R.; Leathers, Heidi M.; Schenk, Christopher J.; Tennyson, Marilyn E.

    2015-09-03

    Using a geology-based assessment methodology, the U.S. Geological Survey estimated mean undiscovered resources of 214 million barrels of oil, 329 billion cubic feet of associated/dissolved natural gas, and 14 million barrels of natural gas liquids in the informal Uteland Butte member of the Green River Formation, Uinta Basin, Utah.

  2. Outcomes by Ethnicity: Sentinel Lymph Node Status in Women With Breast Cancer

    National Research Council Canada - National Science Library

    Hassett, Mary; Hunt, Kelly K; Keyomarsi, Khandan

    2005-01-01

    .... Race/ethnicity and tumor biology may affect outcomes. Since regional lymph node status and tumor markers are strong prognostic indicators, this study examines the role of sentinel lymph node status (SLNS...

  3. The surgical importance of an axillary arch in sentinel node biopsy.

    LENUS (Irish Health Repository)

    Ridgway, P F

    2011-03-01

    When Carl Langer described the aberrant axillary arch in 1846 its relevance in sentinel node biopsy (SNB) surgery could not have been contemplated. The authors define an incidence and elucidate relevance of the arch in SNB of the axilla.

  4. Sentinel node biopsy for melanoma: a study of 241 patients

    DEFF Research Database (Denmark)

    Chakera, Annette Hougaard; Drzewiecki, Krzysztof Tadeusz; Jakobsen, Annika Loft

    2004-01-01

    The aim of this study was to evaluate the sentinel node biopsy (SNB) technique for melanoma using both radiocolloid and blue dye in 241 clinically N0 patients with melanomas >1.0 mm, or thinner lesions exhibiting regression/ulceration. We showed that an increase in injected radioactivity increased...

  5. The Nodal Location of Metastases in Melanoma Sentinel Lymph Nodes

    DEFF Research Database (Denmark)

    Riber-Hansen, Rikke; Nyengaard, Jens; Hamilton-Dutoit, Stephen

    2009-01-01

    BACKGROUND: The design of melanoma sentinel lymph node (SLN) histologic protocols is based on the premise that most metastases are found in the central parts of the nodes, but the evidence for this belief has never been thoroughly tested. METHODS: The nodal location of melanoma metastases in 149...

  6. High-quality MOVPE butt-joint integration of InP/AlGaInAs/InGaAsP-based all-active optical components

    DEFF Research Database (Denmark)

    Kulkova, Irina; Kadkhodazadeh, Shima; Kuznetsova, Nadezda

    2014-01-01

    In this paper, we demonstrate the applicability of MOVPE butt-joint regrowth for integration of all-active InP/AlGaAs/InGaAsP optical components and the realization of high-functionality compact photonic devices. Planar high-quality integration of semiconductor optical amplifiers of various epi...

  7. Development of radiolabeled mannose-dextran conjugates for sentinel lymph node detection

    International Nuclear Information System (INIS)

    Fernandez Nunez, Eutimio Gustavo

    2011-01-01

    Early diagnosis of tumors and metastasis is the current cornerstone in public health policies directed towards the fights against cancer. In breast cancer and melanoma, the sentinel lymph node biopsy has been widely used for diagnoses of metastasis. The minor impact in patient of this technique compared with total nodes dissection and the accurate definition of therapeutic strategies have powered its spreading. The aim of this work was the development of radiolabeled dextran-mannose conjugates for diagnosis using the stable technetium core [ 99m Tc(CO)3] + . Cysteine, a trident ligand, was attached to the conjugates backbone, as a chelate for 99m Tc labeling. Radiolabeling conditions established for all products considered in this study showed high radiochemical purities (> 90%) and specific activities (>59,9 MBq/nmol) as well and high stability obtained through in vitro tests. The lymphatic node uptake increased significantly (4-folds) when mannose units were added to the conjugates compared with those without this monosaccharide. The radiolabeled cysteine-mannose-dextran conjugate with 30 kDa ( 99m Tc - DCM2) showed the best performance at different injected activities among the studied tracers. Concentrations of this radio complex higher than 1 M demonstrated an improvement of lymph node uptakes. Comparisons of 99m Tc - DCM2 performance with commercial radiopharmaceuticals in Brazil market for lymph node detection showed its upper profile. (author)

  8. Riparian spiders as sentinels of PCB contamination across heterogeneous aquatic ecosystems

    Science.gov (United States)

    Riparian spiders are being used increasingly to track spatial patterns of contaminants in and fluxing from aquatic ecosystems. However, our understanding of the circumstances under which spiders are effective sentinels of aquatic pollution is limited. The present study tests the ...

  9. US Domestic Cats as Sentinels for Perfluoroalkyl Substances ...

    Science.gov (United States)

    Perfluoroalkyl substances (PFAS), such as perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA) , are persistent, globally distributed, anthropogenic compounds. The primary source(s) for human exposure are not well understood although within home exposure is likely important since many consumer products have been treated with different PFAS, and people spend much of their lives indoors. Herein, domestic cats were used as sentinels to investigate potential exposure and health linkages. PFAS in serum samples of 72 pet and feral cats, including 11 healthy and 61 with one or more primary disease diagnoses, were quantitated using high-resolution time-of-flight mass spectroscopy. All but one sample had detectable PFAS, with PFOS and perfluorohexane sulfonate (PFHxS) ranging from PFAS prevalence and geometric means in cats were very similar to contemporary NHANES reports of human sera in the U. S. POPULATION: The highest PFAS serum concentrations detected were in indoor cats due to disproportionately elevated PFHxS levels. Ranked by quartile, contingency testing indicated that total PFAS levels were positively associated with living indoors and with higher body weight and body condition scores. Individual PFAS quartile rankings suggested positive associations with respiratory effusion, thyroid, liver, and possibly chronic kidney disease . Domestic cats appear to be useful sentinels for assessing primary

  10. Detection of Genetic Alterations in Breast Sentinel Lymph Node by Array-CGH

    National Research Council Canada - National Science Library

    Cavalli, Luciane R

    2005-01-01

    The sentinel lymph node (SLN) is the first node in the mammary gland to harbor malignant cells in breast tumors with metastasis, and SLN positivity is an indication for axillary lymph node dissection...

  11. Detection of Genetic Alterations in Breast Sentinel Lymph Node by Array-CGH

    National Research Council Canada - National Science Library

    Cavalli, Luciane R

    2006-01-01

    The sentinel lymph node (SLN) is the first node in the mammary gland to harbor malignant cells in breast tumors with metastasis, and SLN positivity is an indication for axillary lymph node dissection...

  12. National equipment of intraoperatory gamma detection in the identification of sentinel lymph node in animal model

    International Nuclear Information System (INIS)

    Santos, Paula Cristina Fada dos; Santos, Ivan Dunshee de Abranches Oliveira; Nahas, Fabio Xerfan; Ferreira, Lydia Masako; Oliveira Filho, Renato Santos de

    2009-01-01

    Purpose: To investigate a national equipment of intraoperatory gamma detection in the identification of sentinel lymph node. Methods: Thirty young adult male rats were used. After anesthetized, animals were divided into two groups of 15 animals each. Animals from group A received dextram 500 - Tc 99 radiopharmaceutical and patent blue V and those from group B received only patent blue V to map the lymphatic drainage. The presence of radiation in the background area, in the area of injection and of the ex vivo sentinel lymph node of group A were measured. After the exeresis, each lymph node in group A and in group B was mixed forming a new random sequence and the radioactive reading of each lymph node was carried out, using both pieces of equipment. Results: The hottest sentinel lymph node was identified by the national equipment when radiation was measured in the area of lymphatic drainage after the Dextran 500 was injected. Also, the ex vivo sentinel lymph node. The national equipment has also detected radiation in the lymph nodes that had not received radiopharmaceutical, leading to false positive, checked by the application of Mann-Whitney tests and Student's paired t-tests. The Cronbach alpha has shown high internal consistency of data 0,9416. Conclusions: The national equipment of intraoperatory gamma detection identifies the LS and showed false positives LS and needs improvement. (author)

  13. Continuous Morbidity Registration at Dutch Sentinel General Practice Network 2009.

    NARCIS (Netherlands)

    Donker, G.A.

    2011-01-01

    The Mexican flu pandemic was limited to a mild pandemic, although the flu incidence rate was higher than in the previous three seasons. At the peak of the epidemic 189 per 100.000 registered patients consulted their general practitioner (GP). The sentinel GP’s of NIVEL registered the number of new

  14. CTC Sentinel. Volume 6, Issue 9. September 2013

    Science.gov (United States)

    2013-09-01

    central government’s control and militants’ ability—and willingness—to quietly blend in.38 A security official in Hadramawt explained the group’s...safari.”17 8 Secunder Kermani, “Drone Victim’s Somalia Visits Probed,” BBC, May 30, 2013. 9 Personal interview, Tam Hussein, community worker who...shared vision of the Center products like the CTC Sentinel could not be produced. If you are interested in learning more about how to support the

  15. The potential of Sentinel-2 spectral configuration to assess rangeland quality

    CSIR Research Space (South Africa)

    Ramoelo, Abel

    2015-08-01

    Full Text Available was measured using the analytical spectral device (ASD) in concert with leaf sample collections for leaf N chemical analysis. ASD reflectance data were resampled to the spectral bands of Sentinel-2 using published spectral response functions. Random forest (RF...

  16. Selective sentinel lymph node biopsy in papillary thyroid carcinoma in patients with no preoperative evidence of lymph node metastasis.

    Science.gov (United States)

    González, Óscar; Zafon, Carles; Caubet, Enric; García-Burillo, Amparo; Serres, Xavier; Fort, José Manuel; Mesa, Jordi; Castell, Joan; Roca, Isabel; Ramón Y Cajal, Santiago; Iglesias, Carmela

    2017-10-01

    Lymphadenectomy is recommended during surgery for papillary thyroid carcinoma when there is evidence of cervical lymph node metastasis (therapeutic) or in high-risk patients (prophylactic) such as those with T3 and T4 tumors of the TNM classification. Selective sentinel lymph node biopsy may improve preoperative diagnosis of nodal metastases. To analyze the results of selective sentinel lymph node biopsy in a group of patients with papillary thyroid carcinoma and no evidence of nodal involvement before surgery. A retrospective, single-center study in patients with papillary thyroid carcinoma and no clinical evidence of lymph node involvement who underwent surgery between 2011 and 2013. The sentinel node was identified by scintigraphy. When the sentinel node was positive, the affected compartment was removed, and when sentinel node was negative, central lymph node dissection was performed. Forty-three patients, 34 females, with a mean age of 52.3 (±17) years, were enrolled. Forty-six (27%) of the 170 SNs resected from 24 (55.8%) patients were positive for metastasis. In addition, 94 (15.6%) out of the 612 lymph nodes removed in the lymphadenectomies were positive for metastases. Twelve of the 30 (40%) low risk patients (cT1N0 and cT2N0) changed their stage to pN1, whereas 12 of 13 (92%) high risk patients (cT3N0 and cT4N0) changed to pN1 stage. Selective sentinel lymph node biopsy changes the stage of more than 50% of patients from cN0 to pN1. This confirms the need for lymph node resection in T3 and T4 tumors, but reveals the presence of lymph node metastases in 40% of T1-T2 tumors. Copyright © 2017 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Preoperative 18F-FDG-PET/CT imaging and sentinel node biopsy in the detection of regional lymph node metastases in malignant melanoma.

    Science.gov (United States)

    Singh, Baljinder; Ezziddin, Samer; Palmedo, Holger; Reinhardt, Michael; Strunk, Holger; Tüting, Thomas; Biersack, Hans-Jürgen; Ahmadzadehfar, Hojjat

    2008-10-01

    The objective of this study was to evaluate the role of preoperative 18F-fluorodeoxyglucose-positron emission tomography/computed tomography scanning, preoperative lymphoscintigraphy (LS), and sentinel lymph node biopsy in patients with malignant melanoma. Fifty-two patients (36 men: 16 women; mean age 55.0+/-13.0 years; median age 61 years; range 17-76 years) with malignant melanoma were selected. According to the latest version of the American Joint Committee on Cancer staging system, the disease in the study patients was initially classified as either stage I or II. The other primary tumor characteristics were mean Breslow depth=2.87 mm and median=2 mm; range 1-12.0 mm and Clarks levels III-V. None of the study patients had clinical or radiological evidence of regional lymph node metastatic disease. At least one sentinel node was identified in all patients. Preoperative LS detected a total of 111 sentinel lymph nodes (average 2.13 sentinel lymph node per patient) and demonstrated a single nodal draining basin in 38 (73%) patients and multiple (2-3 draining basins) in the remaining 14 (27%) patients. Fourteen out of the 52 patients (27%) had at least one involved sentinel node. Positron emission tomography was true positive in two patients with a sentinel node greater than 1 cm and false positive in two other patients. In this study, the detection of sentinel lymph node by LS and gamma probe had a sensitivity of 100%. In contrast, 18F-FDG-PET imaging demonstrated very low sensitivity (14.3%; 95% CI, 2.5 to 44%) and positive predictive value (50%; 95% CI, 9 to 90%) for localizing the subclinical nodal metastases. The specificity, net present value, and diagnostic accuracy were 94.7, 75, and 73%, respectively. Preoperative fluorodeoxyglucose-positron emission tomography/computed tomography imaging is not able to substitute LS/sentinel lymph node biopsy in patients at stage I or II.

  18. Sentinel node biopsy in breast cancer: five years experience from Denmark

    DEFF Research Database (Denmark)

    Christiansen, Peter; Balslev, E.; Jensen, D.

    2008-01-01

    INTRODUCTION: Danish experience from the first five years with sentinel lymph node biopsy (SLNB) as a routine staging procedure in early breast cancer is reported. METHODS: During the period January 1, 2002 to December 31, 2006, 14 923 patients were diagnosed at Danish breast surgical centers...... certified for the sentinel node method. SLNB was performed in 8 338 patients (55.9%). The fraction increased steadily from 43% in 2002 to 67% in 2006. The median follow-up was 1.7 year (range 0-5.2 years). RESULTS: Patients staged with SLNB were younger, had more often BCS, had smaller tumor size, were more...... often hormone receptor positive, and had lower grade, than patients staged with lymph node dissection (ALND). Blue dye and radio colloid were used in combination in 82%. Lymphoscintigraphy was performed in 61%, and frozen section was performed in 87%. Originally, peritumoral injection of tracer was most...

  19. Use of Tc-99m - nanocolloid for sentinel node indentification in cervical cancer

    International Nuclear Information System (INIS)

    Hubalewska, A.; Sowa-Staszczak, A.; Huszczno, B.; Markocka, A.; Pitynski, K.; Basta, A.; Oplawski, M.; Basta, P.

    2003-01-01

    The initial draining lymph node for a primary tumor is referred to as the sentinel node. Firstly adopted in the management of patients with cutaneous melanoma and breast cancer, it is now widely tested in cervical cancer. In patients with cervical cancer, lymph node status is the most important prognostic factor for survival. In patients with cervical cancer FIGO stage I and II pelvic lymph node metastases are expected in 0-16 and 24.5-31% and para-aortic lymph node metastases are expected in 0-22 and 11-19% of patients. The removal of pelvic and para-aortic lymph nodes is essential for assessing the biology of the disease. Lymphoscintigraphy enables the visualisation of lymphatic drainage patterns from a great variety of tumour sites prior to surgery. Therefore, the current procedure is to perform the pre-operative mapping of sentinel nodes by static and/or dynamic lymphoscintigraphy, followed by in vivo identification using a gamma detection probe and selective surgical resection. Between 2001-2003, 37 patients with cervical cancer FIGO stage I-IIa were seemed to be qualified to undergo lymphoscintigraphy. The day before surgery 99m Tc-nanocolloid (100 MBq; 0.5-1.0 ml in volume) was applied in each quadrant of the cervix or around the tumor. The static scintigraphic scans were performed after 2 hours p.i. using a dual-head large-field-of-view Siemens gamma-camera equipped with high resolution collimators. SNs were identified intra-operatively using a handheld gamma detection probe (Navigator GPS-Tyco) and intra-operative lymphatic mapping with blue dye. After a resection of the SNs, a standard radical hysterectomy with pelvic and low para-aortic lymph node dissection was performed. Tumor characteristics were compared with sentinel node detection and with the histopathological and immunohistochemical results. The scintigraphy showed a focal uptake in 35 of the 37 patients. In all women one or more sentinel lymph nodes were identified intra-operatively. Of them, 24

  20. On the synergy of SMAP, AMSR2 AND SENTINEL-1 for retrieving soil moisture

    Science.gov (United States)

    Santi, E.; Paloscia, S.; Pettinato, S.; Brocca, L.; Ciabatta, L.; Entekhabi, D.

    2018-03-01

    An algorithm for retrieving soil moisture content (SMC) from synergic use of both active and passive microwave acquisitions is presented. The algorithm takes advantage of the integration of microwave data from SMAP, Sentinel-1 and AMSR2 for overcoming the SMAP radar failure and obtaining a SMC product at enhanced resolution (0.1° × 0.1°) and improved accuracy with respect to the original SMAP radiometric SMC product. A disaggregation technique based on the Smoothing filter based intensity modulation (SFIM) allows combining the radiometric and SAR data. Disaggregated microwave data are used as inputs of an Artificial Neural Networks (ANN) based algorithm, which is able to exploit the synergy between active and passive acquisitions. The algorithm is defined, trained and tested using the SMEX02 experimental dataset and data simulated by forward electromagnetic models based on the Radiative Transfer Theory. Then the algorithm is adapted to satellite data and tested using one year of SMAP, AMSR2 and Sentinel-1 co-located data on a flat agricultural area located in the Po Valley, in northern Italy. Spatially distributed SMC values at 0.1° × 0.1° resolution generated by the Soil Water Balance Model (SWBM) are considered as reference for this purpose. The synergy of SMAP, Sentinel-1 and AMSR2 allowed increasing the correlation between estimated and reference SMC from R ≅ 0.68 of the SMAP based retrieval up to R ≅ 0.86 of the combination SMAP + Sentinel-1 + AMSR2. The corresponding Root Mean Square Error (RMSE) decreased from RMSE ≅ 0.04 m3/m3 to RMSE ≅ 0.024 m3/m3.

  1. Combination of Landsat and Sentinel-2 MSI data for initial assessing of burn severity

    Science.gov (United States)

    Quintano, C.; Fernández-Manso, A.; Fernández-Manso, O.

    2018-02-01

    Nowadays Earth observation satellites, in particular Landsat, provide a valuable help to forest managers in post-fire operations; being the base of post-fire damage maps that enable to analyze fire impacts and to develop vegetation recovery plans. Sentinel-2A MultiSpectral Instrument (MSI) records data in similar spectral wavelengths that Landsat 8 Operational Land Imager (OLI), and has higher spatial and temporal resolutions. This work compares two types of satellite-based maps for evaluating fire damage in a large wildfire (around 8000 ha) located in Sierra de Gata (central-western Spain) on 6-11 August 2015. 1) burn severity maps based exclusively on Landsat data; specifically, on differenced Normalized Burn Ratio (dNBR) and on its relative versions (Relative dNBR, RdNBR, and Relativized Burn Ratio, RBR) and 2) burn severity maps based on the same indexes but combining pre-fire data from Landsat 8 OLI with post-fire data from Sentinel-2A MSI data. Combination of both Landsat and Sentinel-2 data might reduce the time elapsed since forest fire to the availability of an initial fire damage map. Interpretation of ortho-photograph Pléiades 1 B data (1:10,000) provided us the ground reference data to measure the accuracy of both burn severity maps. Results showed that Landsat based burn severity maps presented an adequate assessment of the damage grade (κ statistic = 0.80) and its spatial distribution in wildfire emergency response. Further using both Landsat and Sentinel-2 MSI data the accuracy of burn severity maps, though slightly lower (κ statistic = 0.70) showed an adequate level for be used by forest managers.

  2. Global Lakes Sentinel Services: Water Quality Parameters Retrieval in Lakes Using the MERIS and S3-OLCI Band Sets

    Science.gov (United States)

    Peters, Steef; Alikas, Krista; Hommersom, Annelies; Latt, Silver; Reinart, Anu; Giardino, Claudia; Bresciani, Mariano; Philipson, Petra; Ruescas, Ana; Stelzer, Kerstin; Schenk, Karin; Heege, Thomas; Gege, Peter; Koponen, Sampsa; Kallio, Karri; Zhang, Yunlin

    2015-12-01

    The European collaborative project GLaSS aims to prepare for the use of the data streams from Sentinel 2 and Sentinel 3. Its focus is on inland waters, since these are considered to be sentinels for land-use- and climate change and need to be monitored closely. One of the objectives of the project is to compare existing water quality algorithms and parameterizations on the basis of in-situ spectral observations and Hydrolight simulations. A first achievement of the project is the collection of over 400 Rrs spectra with accompanying data on CHL, TSM, aCDOM and Secchi depth. Especially the dataset on Lake CDOM measurements represents a rather unique reference dataset.

  3. Processing Sentinel-2 data with ATCOR

    Science.gov (United States)

    Pflug, Bringfried; Makarau, Aliaksei; Richter, Rudolf

    2016-04-01

    Atmospheric correction of satellite images is necessary for many applications of remote sensing. Among them are applications for agriculture, forestry, land cover and land cover change, urban mapping, emergency and inland water. ATCOR is a widely used atmospheric correction tool which can process data of many optical satellite sensors, for instance Landsat, Sentinel-2, SPOT and RapidEye. ATCOR includes a terrain and adjacency correction of satellite images and several special algorithms like haze detection, haze correction, cirrus correction, de-shadowing and empirical methods for BRDF correction. The atmospheric correction tool ATCOR starts with an estimation of the vertical column Aerosol Optical Thickness (AOT550) at 550 nm. The mean uncertainty of the ATCOR-AOT550-estimation was estimated using Landsat and RapidEye data by direct comparison with sunphotometer data as a reference. For Landsat and RapidEye the uncertainty is ΔAOT550nm ≈ 0.03±0.02 for cloudless conditions with a cloud+haze fraction below 1%. Inclusion of cloudy and hazy satellite images into the analysis results in mean ΔAOT550nm ≈ 0.04±0.03 for both RapidEye and Landsat imagery. About 1/3 of the samples perform with the AOT uncertainty better than 0.02 and about 2/3 perform with AOT uncertainty better than 0.05. An accuracy of the retrieved surface reflectance of ±2% (for reflectance reflectance units (for reflectance > 40%) can be achieved for flat terrain, and avoiding the specular and backscattering regions. ATCOR also supports the processing of Sentinel-2 data. First results of processing S2 data and a comparison with AERONET AOT values will be presented.

  4. Vulvar melanoma - Is there a role for sentinel lymph node biopsy?

    NARCIS (Netherlands)

    de Hullu, JA; Hollema, H; Hoekstra, HJ; Piers, DA; Mourits, MJE; Aalders, JG; van der Zee, AGJ

    2002-01-01

    BACKGROUND. The objective of this study was to evaluate the author's recent, preliminary experience with the sentinel lymph node procedure in patient with vulvar melanoma and to compare this experience with treatment and follow-up of patients with vulvar melanomas who were treated previously at

  5. The role of sentinel node biopsy in gynecological cancer : a review

    NARCIS (Netherlands)

    Oonk, Maaike H. M.; van de Nieuwenhof, Hedwig P.; de Hullu, Joanne A.; van der Zee, Ate G. J.

    Purpose of review In early-stage vulvar, cervical and endometrial cancer, lymph node status is the most important prognostic factor. Surgical treatment is aimed at removing the primary tumor and adequately staging the regional lymph nodes. As morbidity of regional lymphadenectomy is high, sentinel

  6. The sentinel lymph node spread determines quantitatively melanoma seeding to non-sentinel lymph nodes and survival.

    Science.gov (United States)

    Ulmer, Anja; Dietz, Klaus; Werner-Klein, Melanie; Häfner, Hans-Martin; Schulz, Claudia; Renner, Philipp; Weber, Florian; Breuninger, Helmut; Röcken, Martin; Garbe, Claus; Fierlbeck, Gerhard; Klein, Christoph A

    2018-03-01

    Complete lymph node dissection (CLND) after a positive sentinel node (SN) biopsy provides important prognostic information in melanoma patients but has been questioned for therapeutic use recently. We explored whether quantification of the tumour spread to SNs may replace histopathology of non-sentinel nodes (NSNs) for staging purposes. We quantified melanoma spread in SNs and NSNs in 128 patients undergoing CLND for a positive SN. In addition to routine histopathology, one-half of each of all 1496 SNs and NSNs was disaggregated into a single cell suspension and stained immunocytochemically to determine the number of melanoma cells per 10 6 lymph node cells, i.e. the disseminated cancer cell density (DCCD). We uncovered melanoma spread to NSNs in the majority of patients; however, the tumour load and the proportion of positive nodes were significantly lower in NSNs than in SNs. The relation between SN and NSN spread could be described by a mathematical function with DCCD NSN  = DCCD SN c /10 1 - c (c = 0.69; 95% confidence interval [CI]: 0.62-0.76). At a median follow-up of 67 months, multivariable Cox regression analyses revealed that DCCD SN (p = 0.02; HR 1.34, 95% CI: 1.05-1.71) and the total number of pathologically positive nodes (p = 0.02; HR 1.53, 95% CI: 1.07-2.22) were significant risk factors after controlling for age, gender, thickness of melanoma and ulceration status. A prognostic model based on DCCD SN and melanoma thickness predicted outcome as accurately as a model including pathological information of both SNs and NSNs. The assessment of DCCD SN renders CLND for staging purposes unnecessary. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Image quality validation of Sentinel 2 Level-1 products: performance status at the beginning of the constellation routine phase

    Science.gov (United States)

    Francesconi, Benjamin; Neveu-VanMalle, Marion; Espesset, Aude; Alhammoud, Bahjat; Bouzinac, Catherine; Clerc, Sébastien; Gascon, Ferran

    2017-09-01

    Sentinel-2 is an Earth Observation mission developed by the European Space Agency (ESA) in the frame of the Copernicus program of the European Commission. The mission is based on a constellation of 2-satellites: Sentinel-2A launched in June 2015 and Sentinel-2B launched in March 2017. It offers an unprecedented combination of systematic global coverage of land and coastal areas, a high revisit of five days at the equator and 2 days at mid-latitudes under the same viewing conditions, high spatial resolution, and a wide field of view for multispectral observations from 13 bands in the visible, near infrared and short wave infrared range of the electromagnetic spectrum. The mission performances are routinely and closely monitored by the S2 Mission Performance Centre (MPC), including a consortium of Expert Support Laboratories (ESL). This publication focuses on the Sentinel-2 Level-1 product quality validation activities performed by the MPC. It presents an up-to-date status of the Level-1 mission performances at the beginning of the constellation routine phase. Level-1 performance validations routinely performed cover Level-1 Radiometric Validation (Equalisation Validation, Absolute Radiometry Vicarious Validation, Absolute Radiometry Cross-Mission Validation, Multi-temporal Relative Radiometry Vicarious Validation and SNR Validation), and Level-1 Geometric Validation (Geolocation Uncertainty Validation, Multi-spectral Registration Uncertainty Validation and Multi-temporal Registration Uncertainty Validation). Overall, the Sentinel-2 mission is proving very successful in terms of product quality thereby fulfilling the promises of the Copernicus program.

  8. Lymphoscintigraphy and triangulated body marking for morbidity reduction during sentinel node biopsy in breast cancer.

    Science.gov (United States)

    Krynyckyi, Borys R; Shafir, Michail K; Kim, Suk Chul; Kim, Dong Wook; Travis, Arlene; Moadel, Renee M; Kim, Chun K

    2005-11-08

    Current trends in patient care include the desire for minimizing invasiveness of procedures and interventions. This aim is reflected in the increasing utilization of sentinel lymph node biopsy, which results in a lower level of morbidity in breast cancer staging, in comparison to extensive conventional axillary dissection. Optimized lymphoscintigraphy with triangulated body marking is a clinical option that can further reduce morbidity, more than when a hand held gamma probe alone is utilized. Unfortunately it is often either overlooked or not fully understood, and thus not utilized. This results in the unnecessary loss of an opportunity to further reduce morbidity. Optimized lymphoscintigraphy and triangulated body marking provides a detailed 3 dimensional map of the number and location of the sentinel nodes, available before the first incision is made. The number, location, relevance based on time/sequence of appearance of the nodes, all can influence 1) where the incision is made, 2) how extensive the dissection is, and 3) how many nodes are removed. In addition, complex patterns can arise from injections. These include prominent lymphatic channels, pseudo-sentinel nodes, echelon and reverse echelon nodes and even contamination, which are much more difficult to access with the probe only. With the detailed information provided by optimized lymphoscintigraphy and triangulated body marking, the surgeon can approach the axilla in a more enlightened fashion, in contrast to when the less informed probe only method is used. This allows for better planning, resulting in the best cosmetic effect and less trauma to the tissues, further reducing morbidity while maintaining adequate sampling of the sentinel node(s).

  9. Rugged: an operational, open-source solution for Sentinel-2 mapping

    Science.gov (United States)

    Maisonobe, Luc; Seyral, Jean; Prat, Guylaine; Guinet, Jonathan; Espesset, Aude

    2015-10-01

    When you map the entire Earth every 5 days with the aim of generating high-quality time series over land, there is no room for geometrical error: the algorithms have to be stable, reliable, and precise. Rugged, a new open-source library for pixel geolocation, is at the geometrical heart of the operational processing for Sentinel-2. Rugged performs sensor-to-terrain mapping taking into account ground Digital Elevation Models, Earth rotation with all its small irregularities, on-board sensor pixel individual lines-of-sight, spacecraft motion and attitude, and all significant physical effects. It provides direct and inverse location, i.e. it allows the accurate computation of which ground point is viewed from a specific pixel in a spacecraft instrument, and conversely which pixel will view a specified ground point. Direct and inverse location can be used to perform full ortho-rectification of images and correlation between sensors observing the same area. Implemented as an add-on for Orekit (Orbits Extrapolation KIT; a low-level space dynamics library), Rugged also offers the possibility of simulating satellite motion and attitude auxiliary data using Orekit's full orbit propagation capability. This is a considerable advantage for test data generation and mission simulation activities. Together with the Orfeo ToolBox (OTB) image processing library, Rugged provides the algorithmic core of Sentinel-2 Instrument Processing Facilities. The S2 complex viewing model - with 12 staggered push-broom detectors and 13 spectral bands - is built using Rugged objects, enabling the computation of rectification grids for mapping between cartographic and focal plane coordinates. These grids are passed to the OTB library for further image resampling, thus completing the ortho-rectification chain. Sentinel-2 stringent operational requirements to process several terabytes of data per week represented a tough challenge, though one that was well met by Rugged in terms of the robustness and

  10. Harmonized Landsat/Sentinel-2 Reflectance Products for Land Monitoring (Invited)

    Science.gov (United States)

    Masek, Jeffrey G.; Dungan, Jennifer L.; Ju, Junchang; Roger, Jean-Claude; Claverie, Martin P.; Skakun, Sergii; Vermote, Eric; Justice, Christopher Owen

    2017-01-01

    Many land applications require more frequent observations than can be obtained from a single 'Landsat class'� sensor. Agricultural monitoring, inland water quality assessment, stand-scale phenology, and numerous other applications all require near-daily imagery at better than 1ha resolution. Thus the land science community has begun expressing a desire for a '30-meter MODIS' global monitoring capability. One cost-effective way to achieve this goal is via merging data from multiple, international observatories into a single virtual constellation. The Harmonized Landsat/Sentinel-2 (HLS) project has been working to generate a seamless surface reflectance product by combining observations from USGS/NASA Landsat-8 and ESA Sentinel-2. Harmonization in this context requires a series of radiometric and geometric transforms to create a single surface reflectance time series agnostic to sensor origin. Radiometric corrections include a common atmospheric correction using the Landsat-8 LaSRC/6S approach, a simple BRDF adjustment to constant solar and nadir view angle, and spectral bandpass adjustments to fit the Landsat-8 OLI reference. Data are then resampled to a consistent 30m UTM grid, using the Sentinel-2 global tile system. Cloud and shadow masking are also implemented. Quality assurance (QA) involves comparison of the output 30m HLS products with near-simultaneous MODIS nadir-adjusted observations. Prototoype HLS products have been processed for approximately 7% of the global land area using the NASA Earth Exchange (NEX) compute environment at NASA Ames, and can be downloaded from the HLS web site (https://hls.gsfc.nasa.gov). A wall-to-wall North America data set is being prepared for 2018. This talk will review the objectives and status of the HLS project, and illustrate applications of high-density optical time series data for agriculture and ecology. We also discuss lessons learned from HLS in the general context of implementing virtual constellations.

  11. Sentinel node biopsy in head and neck cancer

    DEFF Research Database (Denmark)

    Ross, Gary L; Soutar, David S; Gordon MacDonald, D

    2004-01-01

    BACKGROUND: The aim was to determine the reliability and reproducibility of sentinel node biopsy (SNB) as a staging tool in head and neck squamous cell carcinoma (HNSCC) for T1/2 clinically N0 patients by means of a standardized technique. METHODS: Between June 1998 and June 2002, 227 SNB procedu...... cavity/oropharynx in a standardized fashion by centers worldwide. For the majority of these tumors the SNB technique can be used alone as a staging tool....

  12. Application of Deep Learning of Multi-Temporal SENTINEL-1 Images for the Classification of Coastal Vegetation Zone of the Danube Delta

    Science.gov (United States)

    Niculescu, S.; Ienco, D.; Hanganu, J.

    2018-04-01

    Land cover is a fundamental variable for regional planning, as well as for the study and understanding of the environment. This work propose a multi-temporal approach relying on a fusion of radar multi-sensor data and information collected by the latest sensor (Sentinel-1) with a view to obtaining better results than traditional image processing techniques. The Danube Delta is the site for this work. The spatial approach relies on new spatial analysis technologies and methodologies: Deep Learning of multi-temporal Sentinel-1. We propose a deep learning network for image classification which exploits the multi-temporal characteristic of Sentinel-1 data. The model we employ is a Gated Recurrent Unit (GRU) Network, a recurrent neural network that explicitly takes into account the time dimension via a gated mechanism to perform the final prediction. The main quality of the GRU network is its ability to consider only the important part of the information coming from the temporal data discarding the irrelevant information via a forgetting mechanism. We propose to use such network structure to classify a series of images Sentinel-1 (20 Sentinel-1 images acquired between 9.10.2014 and 01.04.2016). The results are compared with results of the classification of Random Forest.

  13. Water striders (family Gerridae): mercury sentinels in small freshwater ecosystems

    International Nuclear Information System (INIS)

    Jardine, Timothy D.; Al, Tom A.; MacQuarrie, Kerry T.B.; Ritchie, Charles D.; Arp, Paul A.; Maprani, Antu; Cunjak, Richard A.

    2005-01-01

    To circumvent some of the previous limitations associated with contaminant-monitoring programs, we tested the suitability of the water strider (Hemiptera: Gerridae) as a mercury sentinel by comparing total mercury concentrations in water striders and brook trout (Salvelinus fontinalis) from a variety of stream sites in New Brunswick, Canada. There was a strong association between the two variables across sites (r 2 = 0.81, P < 0.001) in systems where both atmospheric deposition and a point source (an abandoned gold mine) were likely contributing to ambient mercury levels. In a small stream draining the gold mine tailings pile, water striders had mercury concentrations an order of magnitude higher than those from reference locations. Temporal variation at three southern New Brunswick stream sites was non-significant. These results suggest that water strider mercury levels accurately quantify food chain entry of the element. The use of sentinel species holds great potential for expanding contaminant-monitoring programs. - Water striders accurately reflect the entry of mercury in food chains of small freshwater systems

  14. Sentinel 4: a geostationary imaging UVN spectrometer for air quality monitoring: status of design, performance and development

    Science.gov (United States)

    Gulde, S. T.; Kolm, M. G.; Smith, D. J.; Maurer, R.; Bazalgette Courrèges-Lacoste, G.; Sallusti, M.; Bagnasco, G.

    2017-11-01

    SENTINEL 4 is an imaging UVN (UV-VIS-NIR) spectrometer, developed by Airbus Defence and Space under ESA contract in the frame of the joint European Union (EU)/ESA COPERNICUS program. The mission objective is the operational monitoring of trace gas concentrations for atmospheric chemistry and climate applications. To this end SENTINEL 4 will provide accurate measurements of key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, formaldehyde, as well as aerosol and cloud properties.

  15. Paleoclimate cycles and tectonic controls on fluvial, lacustrine, and eolian strata in upper Triassic Chinle Formation, San Juan basin

    Energy Technology Data Exchange (ETDEWEB)

    Dubiel, R.F. (Geological Survey, Denver, CO (USA))

    1989-09-01

    Sedimentologic study of the Upper Triassic Chinle Formation in the San Juan basin (SJB) indicates that Late Triassic paleoclimate and tectonic movements influenced the distribution of continental lithofacies. The Shinarump, Monitor Butte, and Petrified Forest Members in the lower part of the Chinle consist of complexly interfingered fluvial, floodplain, marsh, and lacustrine rocks; the Owl Rock and Rock Point Members in the upper part consists of lacustrine-basin and eolian sandsheet strata. Facies analysis, vertebrate and invertebrate paleontology, and paleoclimate models demonstrate that the Late Triassic was dominated by tropical monsoonal circulation, which provided abundant precipitation interspersed with seasonally dry periods. Owl Rock lacustrine strata comprise laminated limestones that reflect seasonal monsoonal precipitation and larger scale, interbedded carbonates and fine-grained clastics that represent longer term, alternating wet and dry climatic cycles. Overlying Rock Point eolian sand-sheet and dune deposits indicate persistent alternating but drier climatic cyclicity. Within the Chinle, upward succession of lacustrine, alternating lacustrine/eolian sand-sheet, and eolian sand-sheet/dune deposits reflects an overall decrease in precipitation due to the northward migration of Pangaea out of low latitudes dominated by monsoonal circulation.

  16. Ultrasound of the axilla: where to look for the sentinel lymph node

    International Nuclear Information System (INIS)

    Britton, P.; Moyle, P.; Benson, J.R.; Goud, A.; Sinnatamby, R.; Barter, S.; Gaskarth, M.; Provenzano, E.; Wallis, M.

    2010-01-01

    Aims: The aim of this paper is to guide the radiologist to the most likely location of the sentinel lymph node (SLN). Materials and methods: Patients with invasive breast cancer underwent axillary ultrasound examination. The position and morphological appearances of the lymph nodes were noted and core biopsy (CB) was performed of the largest or most suspicious node. Those patients whose biopsy revealed no evidence of malignancy proceeded to a surgical sentinel lymph node (SLN) biopsy (SLNB) looking for histopathological evidence of previous CB. Results: Of 121 patients who underwent axillary ultrasound and CB no malignancy was identified in 73, all of whom subsequently underwent SLNB. Histological evidence of CB in the SLN was identified in 47 (64%) patients. The position of all the lymph nodes identified on ultrasound and the 47 patients whose SLNs were identified were drawn on composite diagrams of the axilla. Of the 36 nodes identified as sentinel whose position relative to other nodes could be determined, 29 (81%) represented the lowest node identified in the axilla, four (11%) were the second lowest, and three (8%) were the third lowest node. None of the four patients whose CB was from the fourth lowest node had the CB site identified at subsequent SLNB. Conclusion: Ultrasound of the axilla should be carried out in a systematic fashion focusing on level I nodes paying particular attention to the lowest one or two lymph nodes.

  17. Ultrasound of the axilla: where to look for the sentinel lymph node

    Energy Technology Data Exchange (ETDEWEB)

    Britton, P., E-mail: peter.britton@addenbrookes.nhs.u [Cambridge Breast Unit, Addenbrooke' s Hospital, Cambridge (United Kingdom); Moyle, P.; Benson, J.R.; Goud, A.; Sinnatamby, R.; Barter, S.; Gaskarth, M.; Provenzano, E.; Wallis, M. [Cambridge Breast Unit, Addenbrooke' s Hospital, Cambridge (United Kingdom)

    2010-05-15

    Aims: The aim of this paper is to guide the radiologist to the most likely location of the sentinel lymph node (SLN). Materials and methods: Patients with invasive breast cancer underwent axillary ultrasound examination. The position and morphological appearances of the lymph nodes were noted and core biopsy (CB) was performed of the largest or most suspicious node. Those patients whose biopsy revealed no evidence of malignancy proceeded to a surgical sentinel lymph node (SLN) biopsy (SLNB) looking for histopathological evidence of previous CB. Results: Of 121 patients who underwent axillary ultrasound and CB no malignancy was identified in 73, all of whom subsequently underwent SLNB. Histological evidence of CB in the SLN was identified in 47 (64%) patients. The position of all the lymph nodes identified on ultrasound and the 47 patients whose SLNs were identified were drawn on composite diagrams of the axilla. Of the 36 nodes identified as sentinel whose position relative to other nodes could be determined, 29 (81%) represented the lowest node identified in the axilla, four (11%) were the second lowest, and three (8%) were the third lowest node. None of the four patients whose CB was from the fourth lowest node had the CB site identified at subsequent SLNB. Conclusion: Ultrasound of the axilla should be carried out in a systematic fashion focusing on level I nodes paying particular attention to the lowest one or two lymph nodes.

  18. Songbirds as sentinels of mercury in terrestrial habitats of eastern North America

    Science.gov (United States)

    Jackson, Allyson K.; Evers, David C.; Adams, Evan M.; Cristol, Daniel A.; Eagles-Smith, Collin A.; Edmonds, Samuel T.; Gray, Carrie E.; Hoskins, Bart; Lane, Oksana P.; Sauer, Amy; Tear, Timothy

    2015-01-01

    Mercury (Hg) is a globally distributed environmental contaminant with a variety of deleterious effects in fish, wildlife, and humans. Breeding songbirds may be useful sentinels for Hg across diverse habitats because they can be effectively sampled, have well-defined and small territories, and can integrate pollutant exposure over time and space. We analyzed blood total Hg concentrations from 8,446 individuals of 102 species of songbirds, sampled on their breeding territories across 161 sites in eastern North America [geometric mean Hg concentration = 0.25 μg/g wet weight (ww), range of the USEPA Mercury and Air Toxics Standards, which will reduce Hg emissions from coal-fired power plants by over 90 %. Mixed-effects modeling indicated that habitat, foraging guild, and age were important predictors of blood Hg concentrations across species and sites. Blood Hg concentrations in adult invertebrate-eating songbirds were consistently higher in wetland habitats (freshwater or estuarine) than upland forests. Generally, adults exhibited higher blood Hg concentrations than juveniles within each habitat type. We used model results to examine species-specific differences in blood Hg concentrations during this time period, identifying potential Hg sentinels in each region and habitat type. Our results present the most comprehensive assessment of blood Hg concentrations in eastern songbirds to date, and thereby provide a valuable framework for designing and evaluating risk assessment schemes using sentinel songbird species in the time after implementation of the new atmospheric Hg standards.

  19. Sentinel node localization in breast cancer patients using intradermal dye injection

    DEFF Research Database (Denmark)

    Ilum, Lars; Bak, Martin; Olsen, K E

    2000-01-01

    -sectioning and immunohistochemical staining for cytokeratin. In one case a benign epithelial inclusion was found. The sentinel node was false negative in 9.1% of cases. The consensus from the literature is that the best results are achieved using a combination of dye and isotopic techniques....

  20. Lymphoscintigraphy with 99mTc-dextran and radio guided biopsy in sentinel node localization in breast cancer

    International Nuclear Information System (INIS)

    Aguilar, C.R.; Cano, R.A.; Morales, R.E.; Mendoza, G.; Saavedra, P.; Lopez, D.; Carlos, I.; Mendoza, G.; Velarde, R.

    2002-01-01

    Aim: The aim of this work was to evaluate the usefulness of lymphoscintigraphy using Tc 99m-dextran and a gamma detection probe, previous to as well as during radio guided biopsy, in patients with breast cancer and negative findings in axilla, respectively. Materials and Methods: 33 patients (range age 27-74 years) with breast cancer diagnosis, stage I and II, with tumors smaller than 5 cm in diameter and negative findings in axilla were evaluated from June 2000 to Dec 2001 to whom 37 MBq of Tc 99m-Dextran in a volume of 0.2 cc, was infiltrated intradermically, before the patient was placed under gamma camera and the sentinel node location was marked on skin. Biopsy was done using a combined method -gamma counter and vital blue dye- in thirty-three patients. Results: The sentinel node was visualized by lymphoscintigraphy in 32 patients (32/33) between five and twelve minutes after the radiopharmaceutical was injected. Sentinel node biopsy was done in an average time of sixteen minutes, proving that the skin markers were accurate in 90 % (30/33) of cases. Three false negative patients were found. In six patients the frozen biopsy was positive and confirmed using paraffin. The identification rate using both lymphoscintigraphy and radio guided biopsy was 97%. Conclusion: Lymphoscintigraphy with Tc-99m-dextran and surgical biopsy using the combined method could identify sentinel node in 97% of the patients with breast cancer and negative findings in axilla. The rate of false negative (9.3%) was according to expected. Lymphoscintigraphy was able to define the specific lymphatic drainage in each patient (32/33) and visualize the sentinel node to predict the lymphatic flow (32/33), which is specific in each patient. Skin marks were highly accurate in helping the surgeon with less operating time

  1. HURRICANE AND SEVERE STORM SENTINEL (HS3) HURRICANE IMAGING RADIOMETER (HIRAD) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Hurricane and Severe Storm Sentinel (HS3) Hurricane Imaging Radiometer (HIRAD) was collected by the Hurricane Imaging Radiometer (HIRAD), which was a multi-band...

  2. Robotic-Assisted Fluorescence Sentinel Lymph Node Mapping Using Multi-Modal Image-Guidance in an Animal Model

    Science.gov (United States)

    Liss, Michael A.; Stroup, Sean P.; Cand, Zhengtao Qin; Hoh, Carl; Hall, David J.; Vera, David R.; Kane, Christopher J.

    2015-01-01

    Objectives To investigate PET/CT pre-operative imaging and intraoperative detection of a fluorescent-labeled receptor-targeted radiopharmaceutical in a prostate cancer animal model. Methods Three male Beagle dogs underwent an intra-prostatic injection of fluorescent-tagged tilmanocept radio-labeled with both gallium-68 and technetium-99m. One hour after injection a pelvic PET/CT scan was performed for pre-operative sentinel lymph node (SLN) mapping. Definition of SLN was a standardized uptake value (SUV) that exceeded 5% of the lymph node with the highest SUV. Thirty-six hours later we performed robotic-assisted SLN dissection using a fluorescence-capable camera system. Fluorescent lymph nodes were clipped, the abdomen was opened, and the pelvic and retroperitoneal nodes were excised. All excised nodal packets were assayed by in vitro nuclear counting and reported as percent-of-injected dose. Results Pre-operative PET/CT imaging identified a median of three sentinel lymph nodes per animal. All sentinel lymph nodes (100%) identified by the PET/CT were fluorescent during robotic-assisted lymph node dissection. Of all fluorescent nodes visualized by the camera system, 83% (10/12) satisfied the 5%-rule defined by the PET/CT scan. The two lymph nodes that did not qualify accumulated less than 0.002% of the injected dose. Conclusions Fluorescent-labeled tilmanocept has optimal logistical properties to obtain pre-operative PET/CT and subsequent real-time intraoperative confirmation during robotic-assisted sentinel lymph node dissection. PMID:25139676

  3. Wired for success: A history of the Butte, Anaconda & Pacific Railway, 1892--1985

    Science.gov (United States)

    Mutschler, Charles Vincent

    The Butte, Anaconda & Pacific Railway (BA&P) was a standard gauge common carrier short line railroad within the state of Montana. A subsidiary of the Anaconda Copper Mining Company, the BA&P was built to carry ore from mines at Butte, Montana to Anaconda, twenty-six miles away, for concentrating and smelting. Other freight and passenger business was of secondary importance. In 1912, when General Electric contracted to convert the BA&P from steam to electric operation, the short line became a proving ground for main line railroad electrification, and the center of attention from advocates for electric power. Electric operation was demonstrated to be mechanically superior to the use of steam locomotives on the BA&P. Immediately after the BA&P proved the technological feasibility of high voltage direct current for moving heavy freight trains, the Chicago Milwaukee & St. Paul (CM&St.P) electrified over 600 miles of transcontinental main line using the basic technology demonstrated on the BA&P. However, on long distances of track with relatively few trains such as the CM&St.P, the capital cost of the electric distribution system exceeded the operational savings obtained by use of electric locomotives. Steam locomotives remained the primary form of railroad motive power in the United States until the 1950's, when the diesel-electric locomotive combined the mechanical efficiency of electric motors with an on-board diesel generating plant, eliminating the need for expensive electric power supply and distribution wires of conventional electrics. The BA&P purchased three diesels in the early 1950's, but relied primarily on its electric locomotives until 1967, when diesel operation became less costly than continued use of electric motive power. The BA&P offers a microcosmic view of the transformation of one industry in response to technological and economic forces as the United States moved from reliance on coal-burning steam power to electric power and internal combustion

  4. Wind resources at turbine height from Envisat and Sentinel-1 SAR

    DEFF Research Database (Denmark)

    Badger, Merete; Hasager, Charlotte Bay; Pena Diaz, Alfredo

    for the standard output level of 10 m above the sea surface. This presentation demonstrates the effects of two recent improvements related to satellite-based wind resource mapping: 1) The number of satellite samples has increased dramatically since the launch of Sentinel-1A/B 2) A new method looks promising...... National Ice Center. Once the instantaneous wind maps are stored in our database, they can be organized as time series in order to calculate wind resources for any point location or area. Since the time series comprises data from both Envisat and Sentinel-1, a check of the data calibration against one....... To extrapolate the 10-m wind resource maps from SAR to higher levels within the atmospheric boundary layer, we estimate a wind profile for each grid cell in the maps. Simulations from the Weather Research and Forecasting (WRF) model are used to correct this profile for long-term atmospheric stability effects...

  5. Landsat and Sentinel-2A Surface Albedo Estimation and Evaluation Against In Situ Measurements Across the US SURFRAD Network

    Science.gov (United States)

    Franch, B.; Skakun, S.; Vermote, E.; Roger, J. C.

    2017-12-01

    Surface albedo is an essential parameter not only for developing climate models, but also for most energy balance studies. While climate models are usually applied at coarse resolution, the energy balance studies, which are mainly focused on agricultural applications, require a high spatial resolution. The albedo, estimated through the angular integration of the BRDF, requires an appropriate angular sampling of the surface. However, Sentinel-2A sampling characteristics, with nearly constant observation geometry and low illumination variation, prevent from deriving a surface albedo product. In this work, we apply an algorithm developed to derive a Landsat surface albedo to Sentinel-2A. It is based on the BRDF parameters estimated from the MODerate Resolution Imaging Spectroradiometer (MODIS) CMG surface reflectance product (M{O,Y}D09) using the VJB method (Vermote et al., 2009). Sentinel-2A unsupervised classification images are used to disaggregate the BRDF parameters to the Sentinel-2 spatial resolution. We test the results over five different sites of the US SURFRAD network and plot the results versus albedo field measurements. Additionally, we also test this methodology using Landsat-8 images.

  6. Songbirds as Sentinels of Mercury in Terrestrial Foodwebs of Eastern North America

    Science.gov (United States)

    Mercury is a globally distributed environmental contaminant with a variety of deleterious effects in fish, wildlife, and humans. Breeding songbirds may be useful sentinels for mercury because they are relatively easy to sample, have well-defined and small territories, and integra...

  7. There is no bidirectional hot-spot in Sentinel-2 data

    Science.gov (United States)

    Li, Z.; Roy, D. P.; Zhang, H.

    2017-12-01

    The Sentinel-2 multi-spectral instrument (MSI) acquires reflective wavelength observations with directional effects due to surface reflectance anisotropy, often described by the bidirectional reflectance distribution function (BRDF). Recently, we quantified Sentinel-2A (S2A) BRDF effects for 20° × 10° of southern Africa sensed in January and in April 2016 and found maximum BRDF effects for the January data and at the western scan edge, i.e., in the back-scatter direction (Roy et al. 2017). The hot-spot is the term used to describe the increased directional reflectance that occurs over most surfaces when the solar and viewing directions coincide, and has been observed in wide-field of view data such as MODIS. Recently, we observed that Landsat data will not have a hot-spot because the global annual minimum solar zenith angle is more than twice the maximum view zenith angle (Zhang et al. 2016). This presentation examines if there is a S2A hot-spot which may be possible as it has a wider field of view (20.6°) and higher orbit (786 km) than Landsat. We examined a global year of S2A metadata extracted using the Committee on Earth Observation Satellite Visualization Environment (COVE) tool, computed the solar zenith angles in the acquisition corners, and ranked the acquisitions by the solar zenith angle in the back-scatter direction. The available image data for the 10 acquisitions with the smallest solar zenith angle over the year were ordered from the ESA and their geometries examined in detail. The acquisition closest to the hot-spot had a maximum scattering angle of 173.61° on its western edge (view zenith angle 11.91°, solar zenith angle 17.97°) and was acquired over 60.80°W 24.37°N on June 2nd 2016. Given that hot-spots are only apparent when the scattering angle is close to 180° we conclude from this global annual analysis that there is no hot-spot in Sentinel-2 data. Roy, D.P, Li, J., Zhang, H.K., Yan, L., Huang, H., Li, Z., 2017, Examination of

  8. Comparison of peritumoral and subareolar injection of 99mTc sulphur colloid and blue-dye for detection of the sentinel lymph node in breast cancer

    International Nuclear Information System (INIS)

    Jastrzebski, T.; Kopacz, A.; Lass, P.

    2002-01-01

    The new trend in diagnosis of the lymph node is sentinel node biopsy. This method has become increasingly accepted as a minimally invasive alternative to routine axillary dissection. Although the results of numerous studies have shown that sentinel node biopsy can accurately determine the axillary nodal status, the identification rates and false-negative rates have been variable. The sentinel lymph node is defined as the first node in the lymphatic basin that receives the primary lymphatic flow. Between September 1998 and August 2002 123 patients with primary operative breast cancer without clinical palpable axillary lymph nodes were enrolled in the study. There were two groups of patients according to sentinel node identification technique: 51 patients (Group I) received parenchymal, peritumoral injection of 1.0 ml of 16 MBq Tc 99m -radiolabelled sulphur colloid and single intradermal injection of blue-dye over the tumour. The next 72 patients (Group II) received intradermal, periareolar one-site injection of 0.5 ml of 16 MBq Tc 99m -radiolabelled sulphur colloid and blue-dye. Sentinel lymph node was found in 41 (80.4%) cases in Group I and in 67 (93.0%) cases in Group II (p = 0.028). The localisation of the axillary lymph node as a 'hot spot' visualised by lymphoscintigraphy was successful in 39/51 (76.5%) cases in Group I and 67/72 (93.0%) in Group II, p = 0.004). In both groups the success of sentinel node identification in the axillary region by lymphoscintigraphy was connected with sentinel lymph node finding during surgery (Group I: p 99m -radiolabelled sulphur colloid and bluedye is superior to peritumoral 4-sites injections Tc 99m- radiolabelled sulphur colloid and single intradermal injection of blue-dye over the tumour in sentinel lymph node identification. (author)

  9. Evaluation of the novel respiratory virus surveillance program: Pediatric Early Warning Sentinel Surveillance (PEWSS).

    Science.gov (United States)

    Armour, Patricia A; Nguyen, Linh M; Lutman, Michelle L; Middaugh, John P

    2013-01-01

    Infections caused by respiratory viruses are associated with recurrent epidemics and widespread morbidity and mortality. Routine surveillance of these pathogens is necessary to determine virus activity, monitor for changes in circulating strains, and plan for public health preparedness. The Southern Nevada Health District in Las Vegas, Nevada, recruited five pediatric medical practices to serve as sentinel sites for the Pediatric Early Warning Sentinel Surveillance (PEWSS) program. Sentinel staff collected specimens throughout the year from ill children who met the influenza-like illness case definition and submitted specimens to the Southern Nevada Public Health Laboratory for molecular testing for influenza and six non-influenza viruses. Laboratory results were analyzed and reported to the medical and general communities in weekly bulletins year-round. PEWSS data were also used to establish viral respiratory seasonal baselines and in influenza vaccination campaigns. The surveillance program was evaluated using the Centers for Disease Control and Prevention's (CDC's) Updated Guidelines for Evaluating Public Health Surveillance Systems. PEWSS met three of six program usefulness criteria and seven of nine surveillance system attributes, which exceeded the CDC Guidelines evaluation criteria for a useful and complete public health surveillance program. We found that PEWSS is a useful and complete public health surveillance system that is simple, flexible, accessible, and stable.

  10. The added value of a portable gamma camera for intraoperative detection of sentinel lymph node in squamous cell carcinoma of the oral cavity: A case report.

    Science.gov (United States)

    Mayoral, M; Paredes, P; Sieira, R; Vidal-Sicart, S; Marti, C; Pons, F

    2014-01-01

    The use of sentinel lymph node biopsy in squamous cell carcinoma of the oral cavity is still subject to debate although some studies have reported its feasibility. The main reason for this debate is probably due to the high false-negative rate for floor-of-mouth tumors per se. We report the case of a 54-year-old man with a T1N0 floor-of-mouth squamous cell carcinoma who underwent the sentinel lymph node procedure. Lymphoscintigraphy and SPECT/CT imaging were performed for lymphatic mapping with a conventional gamma camera. Sentinel lymph nodes were identified at right Ib, left IIa and Ia levels. However, these sentinel lymph nodes were difficult to detect intraoperatively with a gamma probe owing to the activity originating from the injection site. The use of a portable gamma camera made it possible to localize and excise all the sentinel lymph nodes. This case demonstrates the usefulness of this tool to improve sentinel lymph node detecting in floor-of-mouth tumors, especially those close to the injection area. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  11. Development and field evaluation of the sentinel mosquito arbovirus capture kit (SMACK).

    Science.gov (United States)

    Johnson, Brian J; Kerlin, Tim; Hall-Mendelin, Sonja; van den Hurk, Andrew F; Cortis, Giles; Doggett, Stephen L; Toi, Cheryl; Fall, Ken; McMahon, Jamie L; Townsend, Michael; Ritchie, Scott A

    2015-10-06

    Although sentinel animals are used successfully throughout the world to monitor arbovirus activity, ethical considerations and cross-reactions in serological assays highlight the importance of developing viable alternatives. Here we outline the development of a passive sentinel mosquito arbovirus capture kit (SMACK) that allows for the detection of arboviruses on honey-baited nucleic acid preservation cards (Flinders Technology Associates; FTA®) and has a similar trap efficacy as standard light traps in our trials. The trap efficacy of the SMACK was assessed against Centers for Disease Control and Prevention (CDC) miniature light traps (standard and ultraviolet) and the Encephalitis Vector Survey (EVS) trap in a series of Latin square field trials conducted in North Queensland, Australia. The ability of the SMACK to serve as a sentinel arbovirus surveillance tool was assessed in comparison to Passive Box Traps (PBT) during the 2014 wet season in the Cairns, Australia region and individually in the remote Northern Peninsula Area (NPA) of Australia during the 2015 wet season. The SMACK caught comparable numbers of mosquitoes to both CDC light traps (mean capture ratio 0.86: 1) and consistently outperformed the EVS trap (mean capture ratio 2.28: 1) when CO2 was supplied by either a gas cylinder (500 ml/min) or dry ice (1 kg). During the 2014 arbovirus survey, the SMACK captured significantly (t 6 = 2.1, P = 0.04) more mosquitoes than the PBT, and 2 and 1 FTA® cards were positive for Ross River virus and Barmah Forest virus, respectively, while no arboviruses were detected from PBTs. Arbovirus activity was detected at all three surveillance sites during the NPA survey in 2015 and ca. 27 % of FTA® cards tested positive for either Murray Valley encephalitis virus (2 detections), West Nile virus (Kunjin subtype; 13 detections), or both viruses on two occasions. These results demonstrate that the SMACK is a versatile, simple, and effective passive arbovirus

  12. Hydrothermal Alteration Mineral Mapping Using Sentinel-2A MSI and ASTER Data in the Duolong Ore Concentrating Area,Tibetau Plateau,China

    Science.gov (United States)

    Hu, B.; Wan, B.

    2017-12-01

    The porphyry copper deposits are characterized by alteration zones. Hydrothermal alteration minerals have diagnostic spectral absorption properties in the visible and near-infrared (VNIR) through the shortwave infrared (SWIR) regions. In order to identify the alteration zones in the study area, the Sentinel-2A Multi-Spectral Instrument(MSI) * Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) data and field inspection were combined. The Sentinel-2A MSI has ten bands in the visible and near-infrared (VNIR) regions, which has advantages of detecting ferric iron alteration minerals. Six ASTER bands in the shortwave infrared(SWIR) regions have been demonstrated to be effective in the mapping of Al-OH * Mg-OH group minerals. Integrating ASTER and Sentinel-2A MSI (AM) for mineral mapping can compensate each other's defect. The methods of minimum noise fraction(MNF) * band combination * matched filtering were applied to get Al-OH and Mg-OH group minerals information from AM data. The anomaly-overlaying selection method was used to process three temporal Sentinel-2A MSI data for extracting iron oxides minerals. The ground inspection has confirmed the validity of AM and Sentinel-2A MSI data in mineral mapping. The methodology proved effective in an arid area of Duolong ore concentrating area,Tibet and hereby suggested for application in similar geological settings.

  13. Frozen section is superior to imprint cytology for the intra-operative assessment of sentinel lymph node metastasis in Stage I Breast cancer patients

    Directory of Open Access Journals (Sweden)

    Makita Masujiro

    2006-05-01

    Full Text Available Abstract Background A standard intra-operative procedure for assessing sentinel lymph node metastasis in breast cancer patients has not yet been established. Patients and methods One hundred and thirty-eight patients with stage I breast cancer who underwent sentinel node biopsy using both imprint cytology and frozen section were analyzed. Results Seventeen of the 138 patients had sentinel node involvement. Results of imprint cytology included nine false negative cases (sensitivity, 47.1%. In contrast, only two cases of false negatives were found on frozen section (sensitivity, 88.2%. There were two false positive cases identified by imprint cytology (specificity, 98.3%. On the other hand, frozen section had 100% specificity. Conclusion These findings suggest that frozen section is superior to imprint cytology for the intra-operative determination of sentinel lymph node metastasis in stage I breast cancer patients.

  14. Non sentinel node involvement prediction for sentinel node micrometastases in breast cancer: nomogram validation and comparison with other models.

    Science.gov (United States)

    Houvenaeghel, Gilles; Bannier, Marie; Nos, Claude; Giard, Sylvia; Mignotte, Herve; Jacquemier, Jocelyne; Martino, Marc; Esterni, Benjamin; Belichard, Catherine; Classe, Jean-Marc; Tunon de Lara, Christine; Cohen, Monique; Payan, Raoul; Blanchot, Jerome; Rouanet, Philippe; Penault-Llorca, Frederique; Bonnier, Pascal; Fournet, Sandrine; Agostini, Aubert; Marchal, Frederique; Garbay, Jean-Remi

    2012-04-01

    The risk of non sentinel node (NSN) involvement varies in function of the characteristics of sentinel nodes (SN) and primary tumor. Our aim was to determine and validate a statistical tool (a nomogram) able to predict the risk of NSN involvement in case of SN micro or sub-micrometastasis of breast cancer. We have compared this monogram with other models described in the literature. We have collected data on 905 patients, then 484 other patients, to build and validate the nomogram and compare it with other published scores and nomograms. Multivariate analysis conducted on the data of the first cohort allowed us to define a nomogram based on 5 criteria: the method of SN detection (immunohistochemistry or by standard coloration with HES); the ratio of positive SN out of total removed SN; the pathologic size of the tumor; the histological type; and the presence (or not) of lympho-vascular invasion. The nomogram developed here is the only one dedicated to micrometastasis and developed on the basis of two large cohorts. The results of this statistical tool in the calculation of the risk of NSN involvement is similar to those of the MSKCC (the similarly more effective nomogram according to the literature), with a lower rate of false negatives. this nomogram is dedicated specifically to cases of SN involvement by metastasis lower or equal to 2 mm. It could be used in clinical practice in the way to omit ALND when the risk of NSN involvement is low. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. The importance of tattoo pigment in sentinel lymph nodes.

    Science.gov (United States)

    Soran, Atilla; Menekse, Ebru; Kanbour-Shakir, Amal; Tane, Kaori; Diego, Emilia; Bonaventura, Marguerite; Johnson, Ronald

    2017-01-01

    The presence of pigment in axillary lymph nodes (LN) secondary to migration of tattoo ink can imitate the appearance of a blue sentinel lymph node (SLN) on visual inspection, causing the operator to either miss the true SLN or excise more than is needed. We present patients with tattoos ipsilateral to an early stage breast cancer who underwent a SLN biopsy. Patients were retrospectively reviewed from medical records and clinicopathologic data was collected. A total of 52 LNs were retrieved from 15 patients for sentinel mapping and 29 of them had tattoo pigmentation on pathologic evaluation. Of those 29 SLNs, 2 of them (6.9%) were pigmented, but did not contain either blue dye or Tc-99m (pseudopigmented SLN). Two (3.8%) SLNs were positive for metastasis; both of these had either blue dye or Tc99m uptake, and 1 demonstrated tattoo pigment in the node. In this cohort of patients with ipsilateral tattoos, removed more LNs lead to unnecessary excision which may important for increasing the risk of arm morbidity from SLN biopsy. However, the presence of tattoo pigment did not interfere with understaging for axillary mapping and it did not effect of pathological identification of SLNs positivity.

  16. RICE CROP MAPPING USING SENTINEL-1A PHENOLOGICAL METRICS

    Directory of Open Access Journals (Sweden)

    C. F. Chen

    2016-06-01

    Full Text Available Rice is the most important food crop in Vietnam, providing food more than 90 million people and is considered as an essential source of income for majority of rural populations. Monitoring rice-growing areas is thus important to developing successful strategies for food security in the country. This paper aims to develop an approach for crop acreage estimation from multi-temporal Sentinel-1A data. We processed the data for two main cropping seasons (e.g., winter–spring, summer–autumn in the Mekong River Delta (MRD, Vietnam through three main steps: (1 data pre-processing, (3 rice classification based on crop phenological metrics, and (4 accuracy assessment of the mapping results. The classification results compared with the ground reference data indicated the overall accuracy of 86.2% and Kappa coefficient of 0.72. These results were reaffirmed by close correlation between the government’s rice area statistics for such crops (R2 > 0.95. The values of relative error in area obtained for the winter–spring and summer–autumn were -3.6% and 6.7%, respectively. This study demonstrates the potential application of multi-temporal Sentinel-1A data for rice crop mapping using information of crop phenology in the study region.

  17. Calibrating the SAR SSH of Sentinel-3A and CryoSat-2 over the Corsica Facilities

    Directory of Open Access Journals (Sweden)

    Pascal Bonnefond

    2018-01-01

    Full Text Available Initially developed to monitor the performance of TOPEX/Poseidon and to follow the Jason legacy satellite altimeters at Senetosa Cape, Corsica, this calibration/validation site has been extended to include a new location at Ajaccio. This addition enables the site to monitor Envisat and ERS missions, CryoSat-2 and, more recently, the SARAL/AltiKa mission and Sentinel-3A satellites. Sentinel-3A and CryoSat-2 carry altimeters that use a synthetic aperture radar (SAR mode that is different to the conventional pulse-bandwidth limited altimeters often termed “low resolution mode” (LRM. The aim of this study is to characterize the sea surface height (SSH bias of the new SAR altimeter instruments and to demonstrate the improvement of data quality close to the coast. Moreover, some passes of Sentinel-3A and CryoSat-2 overfly both Senetosa and Ajaccio with only a few seconds time difference, allowing us to evaluate the reliability and homogeneity of both ground sites in term of geodetic datum. The Sentinel-3A and CryoSat-2 SSH biases for the SAR mode are respectively +22 ± 7 mm and −73 ± 5 mm (for CryoSat-2 baseline C products. The results show that the stability of the SAR SSH bias time series is better than standard LRM altimetry. Moreover, compared to standard LRM data, for which the measurements closer than ~10 km from the coast were generally unusable, SAR mode altimeters provide measurements that are reliable at less than few hundred meters from the coast.

  18. Estimating Above-Ground Biomass in Sub-Tropical Buffer Zone Community Forests, Nepal, Using Sentinel 2 Data

    Directory of Open Access Journals (Sweden)

    Santa Pandit

    2018-04-01

    Full Text Available Accurate assessment of above-ground biomass (AGB is important for the sustainable management of forests, especially buffer zone (areas within the protected area, where restrictions are placed upon resource use and special measure are undertaken to intensify the conservation value of protected area areas with a high dependence on forest products. This study presents a new AGB estimation method and demonstrates the potential of medium-resolution Sentinel-2 Multi-Spectral Instrument (MSI data application as an alternative to hyperspectral data in inaccessible regions. Sentinel-2 performance was evaluated for a buffer zone community forest in Parsa National Park, Nepal, using field-based AGB as a dependent variable, as well as spectral band values and spectral-derived vegetation indices as independent variables in the Random Forest (RF algorithm. The 10-fold cross-validation was used to evaluate model effectiveness. The effect of the input variable number on AGB prediction was also investigated. The model using all extracted spectral information plus all derived spectral vegetation indices provided better AGB estimates (R2 = 0.81 and RMSE = 25.57 t ha−1. Incorporating the optimal subset of key variables did not improve model variance but reduced the error slightly. This result is explained by the technically-advanced nature of Sentinel-2, which includes fine spatial resolution (10, 20 m and strategically-positioned bands (red-edge, conducted in flat topography with an advanced machine learning algorithm. However, assessing its transferability to other forest types with varying altitude would enable future performance and interpretability assessments of Sentinel-2.

  19. Effects of Post-Weld Heat Treatment on the Microstructure and Toughness of Flash Butt Welded High-Strength Low-Alloy Steel

    Science.gov (United States)

    Shajan, Nikhil; Arora, Kanwer Singh; Asati, Brajesh; Sharma, Vikram; Shome, Mahadev

    2018-04-01

    Effect of post-weld heat treatment on the weld microstructure, texture, and its correlation to the toughness of flash butt welded joints were investigated. Upon flash butt welding, the α and γ-fiber in the parent material converted to Goss (110)[001], rotated Goss (110)[1 \\bar{1} 0], and rotated cube (001)[1 \\bar{1} 0], (001)[ \\overline{11} 0] textures along the fracture plane. Formation of these detrimental texture components was a result of shear deformation and recrystallization of austenite at temperatures above T nr resulting in a drop of toughness at the weld zone. Inter-critical and sub-critical annealing cycles proved to be less effective in reducing the Goss (110)[001], rotated Goss (110)[1 \\bar{1} 0], and rotated cube (001)[1 \\bar{1} 0], (001)[ \\overline{11} 0] texture components, and therefore, toughness values remained unaffected. Post-weld heat treatment in the austenite phase field at 1000 °C for 5 seconds resulted in the formation of new grains with different orientations leading to a reduction in the texture intensities of both Goss and rotated Goss components and therefore improved weld zone toughness. Prolonged annealing time was found to be ineffective in improving the toughness due to grain growth.

  20. MapSentinel: Can the Knowledge of Space Use Improve Indoor Tracking Further?

    Directory of Open Access Journals (Sweden)

    Ruoxi Jia

    2016-04-01

    Full Text Available Estimating an occupant’s location is arguably the most fundamental sensing task in smart buildings. The applications for fine-grained, responsive building operations require the location sensing systems to provide location estimates in real time, also known as indoor tracking. Existing indoor tracking systems require occupants to carry specialized devices or install programs on their smartphone to collect inertial sensing data. In this paper, we propose MapSentinel, which performs non-intrusive location sensing based on WiFi access points and ultrasonic sensors. MapSentinel combines the noisy sensor readings with the floormap information to estimate locations. One key observation supporting our work is that occupants exhibit distinctive motion characteristics at different locations on the floormap, e.g., constrained motion along the corridor or in the cubicle zones, and free movement in the open space. While extensive research has been performed on using a floormap as a tool to obtain correct walking trajectories without wall-crossings, there have been few attempts to incorporate the knowledge of space use available from the floormap into the location estimation. This paper argues that the knowledge of space use as an additional information source presents new opportunities for indoor tracking. The fusion of heterogeneous information is theoretically formulated within the Factor Graph framework, and the Context-Augmented Particle Filtering algorithm is developed to efficiently solve real-time walking trajectories. Our evaluation in a large office space shows that the MapSentinel can achieve accuracy improvement of 31 . 3 % compared with the purely WiFi-based tracking system.

  1. A Dearth of Numbers: The Actuary and the Sentinel in Global Public Health

    OpenAIRE

    Lakoff, Andrew

    2013-01-01

    How do experts respond to a threat whose probability cannot be calculated but whose consequences could be catastrophic? Andrew Lakoff explores the political dynamics of sentinel devices in the case of the 2009 swine flu pandemic.

  2. CTC Sentinel. Volume 6, Issue 8, August 2013

    Science.gov (United States)

    2013-08-01

    future. Syria,” CTC Sentinel 6:8 (2013). 16 For some interesting work on this issue, see Thomas Hegghammer, “Should I Stay or Should I Go? Explain- ing...the late 1980s and early 1 Arie Perliger, “Democracy in an Ongoing Conflict: The Politics of Defence in Israel,” in James Forest and Isaiah Wilson...people of Syria and Iran…will not Hates Most, U.S. or Iran?” Bloomberg, February 5, 2013. 24 Thomas Erdbrink, “Khamenei: Iran Will Back ‘Any Nations

  3. Does sentinel lymph node biopsy have a role in node- positive head ...

    African Journals Online (AJOL)

    10.1097/MOO.0b013e3283293631]. 6. Taylor RJ, Wahl RL, Sharma PK, et al. Sentinel node localization in oral cavity and oropharynx squamous cell cancer. Arch Otolaryngol Head Neck Surg. 2001;127(8):970-974. 7. Nieuwenhuis EJ, Pijpers R, ...

  4. Glacier Remote Sensing Using Sentinel-2. Part I: Radiometric and Geometric Performance, and Application to Ice Velocity

    Directory of Open Access Journals (Sweden)

    Andreas Kääb

    2016-07-01

    Full Text Available With its temporal resolution of 10 days (five days with two satellites, and significantly more at high latitudes, its swath width of 290 km, and its 10 m and 20 m spatial resolution bands from the visible to the shortwave infrared, the European Sentinel-2 satellites have significant potential for glacier remote sensing, in particular mapping of glacier outlines and facies, and velocity measurements. Testing Level 1C commissioning and ramp-up phase data for initial sensor quality experiences, we find a high radiometric performance, but with slight striping effects under certain conditions. Through co-registration of repeat Sentinal-2 data we also find lateral offset patterns and noise on the order of a few metres. Neither of these issues will complicate most typical glaciological applications. Absolute geo-location of the data investigated was on the order of one pixel at the time of writing. The most severe geometric problem stems from vertical errors of the DEM used for ortho-rectifying Sentinel-2 data. These errors propagate into locally varying lateral offsets in the images, up to several pixels with respect to other georeferenced data, or between Sentinel-2 data from different orbits. Finally, we characterize the potential and limitations of tracking glacier flow from repeat Sentinel-2 data using a set of typical glaciers in different environments: Aletsch Glacier, Swiss Alps; Fox Glacier, New Zealand; Jakobshavn Isbree, Greenland; Antarctic Peninsula at the Larsen C ice shelf.

  5. Tobacco industry responsibility for butts: a Model Tobacco Waste Act.

    Science.gov (United States)

    Curtis, Clifton; Novotny, Thomas E; Lee, Kelley; Freiberg, Mike; McLaughlin, Ian

    2017-01-01

    Cigarette butts and other postconsumer products from tobacco use are the most common waste elements picked up worldwide each year during environmental cleanups. Under the environmental principle of Extended Producer Responsibility, tobacco product manufacturers may be held responsible for collection, transport, processing and safe disposal of tobacco product waste (TPW). Legislation has been applied to other toxic and hazardous postconsumer waste products such as paints, pesticide containers and unused pharmaceuticals, to reduce, prevent and mitigate their environmental impacts. Additional product stewardship (PS) requirements may be necessary for other stakeholders and beneficiaries of tobacco product sales and use, especially suppliers, retailers and consumers, in order to ensure effective TPW reduction. This report describes how a Model Tobacco Waste Act may be adopted by national and subnational jurisdictions to address the environmental impacts of TPW. Such a law will also reduce tobacco use and its health consequences by raising attention to the environmental hazards of TPW, increasing the price of tobacco products, and reducing the number of tobacco product retailers. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Study of the joining of polycarbonate panels in butt joint configuration through friction stir welding

    Science.gov (United States)

    Astarita, Antonello; Boccarusso, Luca; Carrino, Luigi; Durante, Massimo; Minutolo, Fabrizio Memola Capece; Squillace, Antonino

    2018-05-01

    Polycarbonate sheets, 3 mm thick, were successfully friction stir welded in butt joint configuration. Aiming to study the feasibility of the process and the influence of the process parameters joints under different processing conditions, obtained by varying the tool rotational speed and the tool travel speed, were realized. Tensile tests were carried out to characterize the joints. Moreover the forces arising during the process were recorded and carefully studied. The experimental outcomes proved the feasibility of the process when the process parameters are properly set, joints retaining more than 70% of the UTS of the base material were produced. The trend of the forces was described and explained, the influence of the process parameters was also introduced.

  7. The predictive value of single-photon emission computed tomography/computed tomography for sentinel lymph node localization in head and neck cutaneous malignancy.

    Science.gov (United States)

    Remenschneider, Aaron K; Dilger, Amanda E; Wang, Yingbing; Palmer, Edwin L; Scott, James A; Emerick, Kevin S

    2015-04-01

    Preoperative localization of sentinel lymph nodes in head and neck cutaneous malignancies can be aided by single-photon emission computed tomography/computed tomography (SPECT/CT); however, its true predictive value for identifying lymph nodes intraoperatively remains unquantified. This study aims to understand the sensitivity, specificity, and positive and negative predictive values of SPECT/CT in sentinel lymph node biopsy for cutaneous malignancies of the head and neck. Blinded retrospective imaging review with comparison to intraoperative gamma probe confirmed sentinel lymph nodes. A consecutive series of patients with a head and neck cutaneous malignancy underwent preoperative SPECT/CT followed by sentinel lymph node biopsy with a gamma probe. Two nuclear medicine physicians, blinded to clinical data, independently reviewed each SPECT/CT. Activity within radiographically defined nodal basins was recorded and compared to intraoperative gamma probe findings. Sensitivity, specificity, and negative and positive predictive values were calculated with subgroup stratification by primary tumor site. Ninety-two imaging reads were performed on 47 patients with cutaneous malignancy who underwent SPECT/CT followed by sentinel lymph node biopsy. Overall sensitivity was 73%, specificity 92%, positive predictive value 54%, and negative predictive value 96%. The predictive ability of SPECT/CT to identify the basin or an adjacent basin containing the single hottest node was 92%. SPECT/CT overestimated uptake by an average of one nodal basin. In the head and neck, SPECT/CT has higher reliability for primary lesions of the eyelid, scalp, and cheek. SPECT/CT has high sensitivity, specificity, and negative predictive value, but may overestimate relevant nodal basins in sentinel lymph node biopsy. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Readiness of the Belgian network of sentinel general practitioners to deliver electronic health record data for surveillance purposes: results of survey study.

    Science.gov (United States)

    Boffin, Nicole; Bossuyt, Nathalie; Vanthomme, Katrien; Van Casteren, Viviane

    2010-06-25

    In order to proceed from a paper based registration to a surveillance system that is based on extraction of electronic health records (EHR), knowledge is needed on the number and representativeness of sentinel GPs using a government-certified EHR system and the quality of EHR data for research, expressed in the compliance rate with three criteria: recording of home visits, use of prescription module and diagnostic subject headings. Data were collected by annual postal surveys between 2005 and 2009 among all sentinel GPs. We tested relations between four key GP characteristics (age, gender, language community, practice organisation) and use of a certified EHR system by multivariable logistic regression. The relation between EHR software package, GP characteristics and compliance with three quality criteria was equally measured by multivariable logistic regression. A response rate of 99% was obtained. Of 221 sentinel GPs, 55% participated in the surveillance without interruption from 2005 onwards, i.e. all five years, and 78% were participants in 2009. Sixteen certified EHR systems were used among 91% of the Dutch and 63% of the French speaking sentinel GPs. The EHR software package was strongly related to the community and only one EHR system was used by a comparable number of sentinel GPs in both communities. Overall, the prescription module was always used and home visits were usually recorded. Uniform subject headings were only sometimes used and the compliance with this quality criterion was almost exclusively related to the EHR software package in use. The challenge is to progress towards a sentinel network of GPs delivering care-based data that are (partly) extracted from well performing EHR systems and still representative for Belgian general practice.

  9. The 'Sentinel Node' Concept: More Questions Raised than Answers Provided?

    Science.gov (United States)

    Schlag

    1998-01-01

    preoperative lymph node staging. However, there is none. General criteria like size, shape, structure, or texture in variable imaging modalities are unreliable. While it is still too early to definitely evaluate in this context new diagnostic modalities like PET, immunoscintigraphy, or contrast-enhanced MRI, the initial results do not provoke clear enthusiasm toward the development of a sensitive and specific staging tool with regard to the nodal status. Adequate specificity may be obtained by external or endoluminal ultrasound-guided fine needle biopsies. However, uncertainty arises from eventually unrepresentative tissue sampling. The sentinel lymphonodectomy technique may remedy the dilemma, enabling a risk-adapted, individual indication for regional lymphatic dissection. This concept, first introduced in 1977 by Cabanas into the treatment of penis carcinoma, is based on the evidence of orderly and predictable lymphatic drainage pathways. Tumor cell progression within the lymphatic system seems to follow a sequential pattern. Primary draining lymph nodes possess the structural and functional capability to retain and to fight tumor cells efficiently. The 'sentinel node' is defined as the first tumor draining filter, and, if uninvolved, should thus adequately predict the nodal status of the disease. Skip metastases beyond an uninvolved sentinel node are supposed to be a very rare event. The reliability of the 'Cabanas approach', however, was limited by its relatively poor localization technique, and therefore failed to gain widespread acceptance. Unfortunately, the significance of the concept was not fully appreciated at the time. It is to Morton's credit that the procedure was reinstituted in malignant melanoma through a dye injection technique at the primary tumor site. This led to a rapid development and refinement of intraoperative lymphatic mapping. One major step in this process was to use radiolabeled colloids in conjunction with gamma-camera imaging or gamma probe

  10. Geology of the Saddle Mountains between Sentinel Gap and 119030' longitude

    International Nuclear Information System (INIS)

    Reidel, S.P.

    1978-09-01

    Members and flows of the Grande Ronde, Wanapum, and Saddle Mountains basalts of the Columbia River Basalt Group were mapped in the Saddle Mountains between Sentinel Gap and the eastern edge of Smyrna Bench. The Grande Ronde Basalt consists of the Schwana (low-MgO) and Sentinel Bluffs (high-MgO) members (informal names). The Wanapum Basalt consists of the aphyric and phyric units of the Frenchman Springs Member, the Roza-Like Member, and the Priest Rapids Member. The Saddle Mountains Basalt consists of the Wahluke, Huntzinger, Pomona, Mattawa, and Elephant Mountain basalts. The Wanapum and Saddle Mountains basalts are unevenly distributed across the Saddle Mountains. The Wanapum Basalt thins from south to north and across a northwest-southeast-trending axis at the west end of Smyrna Bench. The Priest Rapids, Roza-Like, and aphyric Frenchman Springs units are locally missing across this zone. The Saddle Mountains basalt has a more irregular distribution and, within an area between Sentinel Gap and Smyrna Bench, is devoid of the basalt. The Wahluke, Huntzinger, and Mattawa flows are locally present, but the Pomona is restricted to the southern flank west of Smyrna Bench, and the Elephant Mountain Basalt only occurs on the flanks and in three structurally controlled basins on the northwest side. The structure of the Saddle Mountains is dominated by an east-west trend and, to a lesser degree, controlled by a northwest-southeast and northeast-southwest trend. The geomorphological expression of the Saddle Mountains results from the east-west fold set and the Saddle Mountains fault along the north side. The oldest structures follow the northwest-southeast trend. The distribution of the flows, combined with the structural features, indicates a complex geologic history for the Saddel Mountains

  11. Sentinel pigeon surveillance for West Nile virus by using lard-can traps at differing elevations and canopy cover classes.

    Science.gov (United States)

    Deegan, Carrie S; Burns, Joseph E; Huguenin, Michael; Steinhaus, Eliza Y; Panella, Nicholas A; Beckett, Susan; Komar, Nicholas

    2005-11-01

    Sentinel pigeons, Columba livia, were installed in lard-can traps at heights of 1.5 m and 7.6-9.1 m within differing canopy cover classes in New York City. Adult mosquitoes were collected weekly from July to October 2002, as were serum samples from each pigeon. Culex pipiens L. and Culex restuans Theobald comprised 97% of mosquitoes collected and were most numerous in canopy-level, forested traps. The West Nile virus (family Flaviviridae, genus Flavivirus, WNV) seroconversion rate was significantly greater for pigeons in canopy-level traps, although seroconversions occurred concurrently with human cases in the city and were of little prognostic value to public health agencies. Our results indicate that sentinel pigeons were most effective for monitoring enzootic transmission of WNV when placed in single-sentinel caging 7.6-9.1 m above ground level.

  12.  Ischemic Stroke Secondary to Aortic Dissection Following Rifle Butt Recoil Chest Injury: A Case Report

    Directory of Open Access Journals (Sweden)

    John Valiath

    2011-11-01

    Full Text Available  Ischemic stroke secondary to aortic dissection is not uncommon. We present a patient with left hemiplegia secondary to Stanford type A aortic dissection extending to the supra-aortic vessels, which was precipitated by rifle butt recoil chest injury. The diagnosis of aortic dissection was delayed due to various factors. Finally, the patient underwent successful Bentall procedure with complete resolution of symptoms. This case emphasizes the need for caution in the use of firearms for recreation and to take precautions in preventing such incidents. In addition, this case illustrates the need for prompt cardiovascular physical examination in patients presenting with stroke.

  13. Towards monitoring surface and subsurface lakes on the Greenland Ice Sheet using Sentinel-1 SAR and Landsat-8 OLI imagery

    Science.gov (United States)

    Miles, Katie E.; Willis, Ian C.; Benedek, Corinne L.; Williamson, Andrew G.; Tedesco, Marco

    2017-07-01

    Supraglacial lakes are an important component of the Greenland Ice Sheet’s mass balance and hydrology, with their drainage affecting ice dynamics. This study uses imagery from the recently launched Sentinel-1A Synthetic Aperture Radar (SAR) satellite to investigate supraglacial lakes in West Greenland. A semi-automated algorithm is developed to detect surface lakes from Sentinel-1 images during the 2015 summer. A combined Landsat-8 and Sentinel-1 dataset, which has a comparable temporal resolution to MODIS (3 days versus daily) but a higher spatial resolution (25-40 m versus 250-500 m), is then used together with a fully-automated lake drainage detection algorithm. Rapid (days) and slow (> 4 days) drainages are investigated for both small (summer. Drainage events of small lakes occur at lower elevations (mean 159 m), and slightly earlier (mean 4.5 days) in the melt season than those of large lakes. The analysis is extended manually into the early winter to calculate the dates and elevations of lake freeze-through more precisely than is possible with optical imagery (mean 30 August; 1270 m mean elevation). Finally, the Sentinel-1 imagery is used to detect subsurface lakes and, for the first time, their dates of appearance and freeze-through (mean 9 August and 7 October, respectively). These subsurface lakes occur at higher elevations than the surface lakes detected in this study (mean 1593 m and 1185 m, respectively). Sentinel-1 imagery therefore provides great potential for tracking melting, water movement and freezing within both the firn zone and ablation area of the Greenland Ice Sheet.

  14. COMET-LICSAR: Systematic Deformation Monitoring of Fault Zones and Volcanoes with the Sentinel-1 Constellation

    Science.gov (United States)

    Spaans, K.; Wright, T. J.; Hooper, A. J.; Hatton, E. L.; González, P. J.; Bhattarai, S.; Biggs, J.; Crippa, P.; Ebmeier, S. K.; Elliott, J.; Gaddes, M.; Li, Z.; Parsons, B.; Qiu, Q.; McDougall, A.; Walters, R. J.; Weiss, J. R.; Ziebart, M.

    2017-12-01

    The Sentinel-1 constellation represents a major advance in our ability to monitor our planet's hazardous tectonic and volcanic zones. Here we present the latest progress from COMET (*), where we are now providing deformation results to the community for volcanoes and the tectonic belts (**). COMET now responds routinely to most significant continental earthquakes - Sentinel-1 allows us to do this within a few days for most earthquakes. For example, after the M7.8 Kaikoura (New Zealand) earthquake we supplied a processed interferogram to the community just 5 hours and 37 minutes after the Sentinel-1 acquisition. By the end of 2017, we will be producing interferogram products systematically for all earthquakes larger than M 6.0. For deformation data to be useful for preparedness, we need accuracy on the order of 1 mm/yr or better. This requires mass processing of long time series of radar acquisitions. We are currently (July 2017) processing interferograms systematically for the entire Alpine-Himalayan belt ( 9000 x 2000 km) using our LiCSAR chain, making interferograms and coherence products available to the community. By December 2017, we plan to process a wider tectonic area and the majority of subaerial volcanoes. We currently serve displacement and coherence grids, but plan to provide average deformation rates and time series. Results are available through our dedicated portal (**), and are being linked to the ESA G-TEP and EPOS during 2017. We will show the latest results for tectonics and volcanism, and discuss how these can be used to build value-added products, including (i) maps of tectonic strain (ii) maps of seismic hazard (iii) volcano deformation alerts. The accuracy of these products will improve as the number of data products acquired by Sentinel-1 increases, and as the time series lengthen. *http://comet.nerc.ac.uk**http://comet.nerc.ac.uk/COMET-LiCS-portal/

  15. a Preliminary Investigation on Comparison and Transformation of SENTINEL-2 MSI and Landsat 8 Oli

    Science.gov (United States)

    Chen, F.; Lou, S.; Fan, Q.; Li, J.; Wang, C.; Claverie, M.

    2018-05-01

    A PRELIMINARY INVESTIGATION ON COMPARISON AND TRANSFORMATION OF SENTINEL-2 MSI AND LANDSAT 8 OLI Timely and accurate earth observation with short revisit interval is usually necessary, especially for emergency response. Currently, several new generation sensors provided with similar channel characteristics have been operated onboard different satellite platforms, including Sentinel-2 and Landsat 8. Joint use of the observations by different sensors offers an opportunity to meet the demands for emergency requirements. For example, through the combination of Landsat and Sentinel-2 data, the land can be observed every 2-3 days at medium spatial resolution. However, differences are expected in radiometric values (e.g., channel reflectance) of the corresponding channels between two sensors. Spectral response function (SRF) is taken as an important aspect of sensor settings. Accordingly, between-sensor differences due to SRFs variation need to be quantified and compensated. The comparison of SRFs shows difference (more or less) in channel settings between Sentinel-2 Multi-Spectral Instrument (MSI) and Landsat 8 Operational Land Imager (OLI). Effect of the difference in SRF on corresponding values between MSI and OLI was investigated, mainly in terms of channel reflectance and several derived spectral indices. Spectra samples from ASTER Spectral Library Version 2.0 and Hyperion data archives were used in obtaining channel reflectance simulation of MSI and OLI. Preliminary results show that MSI and OLI are well comparable in several channels with small relative discrepancy (model is not ensured when the target belongs to another spectra collection. If an improper transformation model is selected, the between-sensor discrepancy will even largely increase. In conclusion, improvement in between-sensor consistency is possibly a challenge, through linear transformation based on model(s) generated from other spectra collections.

  16. The sentinel lymph concept in breast cancer. World J Nucl Med 2004; 3: 4-7 [Letter-to-the-editor

    International Nuclear Information System (INIS)

    Canizales, A.L.; Al-Yasi, A.; Gambhir, S.; Morris, G.; Granowska, M.; Britton, K.E.

    2005-01-01

    Full test: The commentary on Sentinel Lymph Node Biopsy in Breast Cancer in the World Journal of Nuclear Medicine (Volume- 3, January 2004) by Canizales AL et al made an interesting reading.We would like to offer the following Comments: 1. It was indeed exciting to find that the ratio of radioactivity in involved vs. the uninvolved axillary lymph nodes was 4:1, and the involved sentinel lymph nodes had shown about 25 times more tracer uptake as compared to the uninvolved sentinel lymph nodes (p<0.009). This observation throws new light on the subject and further studies into this will be invaluable. That certain nodes have preference for colloid and malignant cells, either by the virtue of anatomical location or larger lymphatics is something to be verified by further studies may be by excision of the lymphatic channels and its studies. Further, it would be interesting to study if any particular histopathology has preferential lodging or if it is true for all variants of breast cancer. 2. There has been a debate going on for the past several years to identify the best method of injection of nannocolloid for imaging sentinel lymph node in breast cancer. The debate may be unwarranted. We feel that peri-tumoral injection would be the most accurate. This is because, what we are interested in is studying the lymphatic drainage of the breast area in which the cancer (tumour) is present. It may be noted that every point in the breast has definite area/areas of drainage. A point source that corresponds to a very small mass will have drainage to either axilla/internal mammary/supraclavicular lymph nodes. A large tumour may drain into more than one lymph node. What we are trying to achieve by injecting a radiocolloid around the tumour is to simulate the actual lymphatic drainage of the tumour. A periareolar /subareolar injection will never be able to simulate the actual lymphatic drainage from the tumour site particularly when the existence of subareolar plexus of sappy is

  17. Patterns of Cellular Distribution with the Sentinel Node Positive for Breast Cancer

    International Nuclear Information System (INIS)

    Tsiapali, E.; Schmidt, M.M.; Dizon, D.; Steinhoff, M.; Gass, J.

    2011-01-01

    Background. Sentinel node biopsy (SNB) represents the standard of care in breast cancer axillary evaluation. Our study aims to characterize the patterns of malignant cell distribution within the sentinel nodes (SN). Methods. In a retrospective IRB-approved study, we examined the anatomic location of the nodal area with the highest radioactive signal or most intense blue staining (hot spot) and its distance from the metastatic foci. Results. 58 patients underwent SNB between January 2006 and February 2007. 12 patients with 19 positive SN were suitable for analysis. 4 (21%) metastases were located in the nodal hilum and 15 (79%) in the cortex. 6 (31%) metastases were found adjacent to the hotspot, and 9 (47%) within 4 mm of the hotspot. Conclusions. In our pilot series, SN metastases were within 4 mm of the hotspot in 78% of the cases. Pathologic analysis focused in that area may contribute to the more accurate identification of nodal metastases

  18. Coastal wind study based on Sentinel-1 and ground-based scanning lidar

    DEFF Research Database (Denmark)

    Hasager, Charlotte Bay; Badger, Merete; Pena Diaz, Alfredo

    Winds in the coastal zone have importance for near-shore wind farm planning. Recently the Danish Energy Agency gave new options for placing offshore wind farms much closer to the coastlines than previously. The new tender areas are located from 3 to 8 km from the coast. Ground-based scanning lidar...... located on land can partly cover this area out to around 15 km. In order to improve wind farm planning for near-shore coastal areas, the project‘Reducing the Uncertainty of Near-shore Energy estimates from meso- and micro-scale wind models’ (RUNE) is established. The measurement campaign starts October....... The various observation types have advantages and limitations; one advantage of both the Sentinel-1 and the scanning lidar is that they both observe wind fields covering a large area and so can be combined for studying the spatial variability of winds. Sentinel-1 are being processed near-real-time at DTU Wind...

  19. Tool material effect on the friction stir butt welding of AA2124-T4 Alloy Matrix MMC

    Directory of Open Access Journals (Sweden)

    Yahya Bozkurt

    2018-01-01

    Full Text Available The purpose of the present work is to study on the effect of material properties tool on friction stir butt welding of AA2124-T4 alloy matrix MMC. Uncoated tool, coated tool with a CrN, and coated tool with AlTiN were used to weld aluminum MMC plates. Macrostructure and microstructure observations, ultimate tensile strength, wear resistance, and chemical analysis were carried out to determine the appropriate tool for joining these composite plates. Results showed that the good welded joints could be obtained when a tool is coated with AlTiN.

  20. Integrated FEM-DBEM simulation of crack propagation in AA2024-T3 FSW butt joints considering manufacturing effects

    DEFF Research Database (Denmark)

    Sonne, Mads Rostgaard; Carlone, P.; Citarella, R.

    2015-01-01

    This paper deals with a numerical and experimental investigation on the influence of residual stresses on fatigue crack growth in AA2024-T3 friction stir welded butt joints. An integrated FEM-DBEM procedure for the simulation of crack propagation is proposed and discussed. A numerical FEM model...... of the welding process of precipitation hardenable AA2024-T3 aluminum alloy is employed to infer the process induced residual stress field. The reliability of the FEM simulations with respect to the induced residual stresses is assessed comparing numerical outcomes with experimental data obtained by means...

  1. Busted Butte Phase 2: Introduction and Analytical Modeling of Nonreactive Tracer and Lithium Breakthrough

    International Nuclear Information System (INIS)

    Turin, H.J.; Soll, W.E.

    2002-01-01

    The Busted Butte Unsaturated-Zone Transport Test Facility is located approximately 8 km southeast of Yucca Mountain, and was designed to address uncertainties associated with flow and transport in the UZ site-process models for Yucca Mountain. Busted Butte Phase 2 consisted of a 10m x 10m x 7m test block. From July 1988 through October 2000, complex tracer mixtures were injected continuously at 77 discrete points located along eight parallel 10-m boreholes arranged in two horizontal planes. In August 1999, iodide was added to the tracer mixture to explore the effects of initial hydraulic transients. During the course of the experiment, porewater samples were collected at regular intervals using sorbing-paper collection pads, emplaced into fifteen horizontal and inclined 10-m collection boreholes, oriented perpendicular to the injection boreholes. Potential travel distances ranged from 20 cm to over 500 cm. Nonreactive tracer and weakly sorbing lithium breakthrough was observed at most of the collection points during the injection period. Following termination of injection, approximately 800 rock samples were collected using overcore and mineback techniques, and analyzed for tracer concentration. Rock analyses are discussed in a subsequent paper. To complement complex 3-dimensional finite-element modeling of the entire block, bromide, iodide, and lithium breakthrough onto the collection pads has been modeled with CXTFIT. This simple 1-dimensional analytical code uses a non-linear curve-fitting routine to estimate transport parameters including apparent velocity, dispersivity, and field retardation factors. Preliminary results show that: (1) Bromide and iodide behaved similarly, despite the fact that bromide was injected in a strongly transient flow field, while iodide injection began after flow had approached steady state conditions. (2) With the exception of the closest collection points, tracer velocities remained relatively constant, indicating that transport was

  2. Microstructure and mechanical properties of resistance upset butt welded 304 austenitic stainless steel joints

    International Nuclear Information System (INIS)

    Sharifitabar, M.; Halvaee, A.; Khorshahian, S.

    2011-01-01

    Graphical abstract: Three different microstructural zones formed at different distances from the joint interface in resistance upset butt welding of 304 austenitic stainless steel. Highlights: → Evaluation of microstructure in resistance upset welding of 304 stainless steel. → Evaluation of welding parameters effects on mechanical properties of the joint. → Introducing the optimum welding condition for joining stainless steel bars. -- Abstract: Resistance upset welding (UW) is a widely used process for joining metal parts. In this process, current, time and upset pressure are three parameters that affect the quality of welded products. In the present research, resistance upset butt welding of 304 austenitic stainless steel and effect of welding power and upset pressure on microstructure, tensile strength and fatigue life of the joint were investigated. Microstructure of welds were studied using scanning electron microscopy (SEM). X-ray diffraction (XRD) analysis was used to distinguish the phase(s) that formed at the joint interface and in heat affected zone (HAZ). Energy dispersive spectroscopy (EDS) linked to the SEM was used to determine chemical composition of phases formed at the joint interface. Fatigue tests were performed using a pull-push fatigue test machine and the fatigue properties were analyzed drawing stress-number of cycles to failure (S-N) curves. Also tensile strength tests were performed. Finally tensile and fatigue fracture surfaces were studied by SEM. Results showed that there were three different microstructural zones at different distances from the joint interface and delta ferrite phase has formed in these regions. There was no precipitation of chromium carbide at the joint interface and in the HAZ. Tensile and fatigue strengths of the joint decreased with welding power. Increasing of upset pressure has also considerable influence on tensile strength of the joint. Fractography of fractured samples showed that formation of hot spots at

  3. Surveillance for travel-related disease--GeoSentinel Surveillance System, United States, 1997-2011.

    Science.gov (United States)

    Harvey, Kira; Esposito, Douglas H; Han, Pauline; Kozarsky, Phyllis; Freedman, David O; Plier, D Adam; Sotir, Mark J

    2013-07-19

    In 2012, the number of international tourist arrivals worldwide was projected to reach a new high of 1 billion arrivals, a 48% increase from 674 million arrivals in 2000. International travel also is increasing among U.S. residents. In 2009, U.S. residents made approximately 61 million trips outside the country, a 5% increase from 1999. Travel-related morbidity can occur during or after travel. Worldwide, 8% of travelers from industrialized to developing countries report becoming ill enough to seek health care during or after travel. Travelers have contributed to the global spread of infectious diseases, including novel and emerging pathogens. Therefore, surveillance of travel-related morbidity is an essential component of global public health surveillance and will be of greater importance as international travel increases worldwide. September 1997-December 2011. GeoSentinel is a clinic-based global surveillance system that tracks infectious diseases and other adverse health outcomes in returned travelers, foreign visitors, and immigrants. GeoSentinel comprises 54 travel/tropical medicine clinics worldwide that electronically submit demographic, travel, and clinical diagnosis data for all patients evaluated for an illness or other health condition that is presumed to be related to international travel. Clinical information is collected by physicians with expertise or experience in travel/tropical medicine. Data collected at all sites are entered electronically into a database, which is housed at and maintained by CDC. The GeoSentinel network membership program comprises 235 additional clinics in 40 countries on six continents. Although these network members do not report surveillance data systematically, they can report unusual or concerning diagnoses in travelers and might be asked to perform enhanced surveillance in response to specific health events or concerns. During September 1997-December 2011, data were collected on 141,789 patients with confirmed or

  4. The efficacy of natalizumab in patients with relapsing multiple sclerosis: subgroup analyses of AFFIRM and SENTINEL.

    LENUS (Irish Health Repository)

    Hutchinson, Michael

    2012-02-01

    The AFFIRM and SENTINEL studies showed that natalizumab was effective both as monotherapy and in combination with interferon beta (IFNbeta)-1a in patients with relapsing multiple sclerosis (MS). Further analyses of AFFIRM and SENTINEL data were conducted to determine the efficacy of natalizumab in prespecified patient subgroups according to baseline characteristics: relapse history 1 year before randomization (1, 2, > or = 3), Expanded Disability Status Scale score (< or = 3.5, > 3.5), number of T2 lesions (< 9, > or = 9), presence of gadolinium-enhancing (Gd+) lesions (0, > or = 1), age (< 40, > or = 40) and gender (male, female). A post hoc analysis was conducted to determine the efficacy of natalizumab in patients with highly active disease (i. e., > or = 2 relapses in the year before study entry and > or = 1 Gd+ lesion at study entry). In both AFFIRM and SENTINEL studies natalizumab reduced the annualized relapse rates across all subgroups (except the small subgroups with < 9 baseline T2 lesions) over 2 years. In AFFIRM, natalizumab significantly reduced the risk of sustained disability progression in most subgroups. In SENTINEL, natalizumab significantly reduced the risk of sustained disability progression in the following subgroups: > or = 9 T2 lesions at baseline, > or = 1 Gd+ lesions at baseline, female patients and patients < 40 years of age. Natalizumab reduced the risk of disability progression by 64 % and relapse rate by 81 % in treatment- naive patients with highly active disease and by 58 % and 76 %, respectively, in patients with highly active disease despite IFNbeta-1a treatment. These results indicate that natalizumab is effective in reducing disability progression and relapses in patients with relapsing MS, particularly in patients with highly active disease.

  5. Improved mapping of tropospheric air quality gases based on the Copernicus Sentinel 5 Precursor/TROPOMI mission

    Science.gov (United States)

    Van Roozendael, Michel; De Smedt, Isabelle; Theys, Nicolas; Danckaert, Thomas; Yu, Huan; Lerot, Christophe; van Gent, Jeroen; Vlietinck, Jonas

    2017-04-01

    Scheduled for launch in summer 2017, the Sentinel 5 Precursor (S5P) mission having onboard the TROPOMI payload will fly on a sun-synchronous polar orbit and provide daily global early-afternoon observations of a number of key atmospheric trace gases at the unprecedented spatial resolution of 7x3.5 km2. By the early 2020's, S5P will be complemented by geostationary observations from the Sentinel 4 UVN instrument to be delivered at hourly resolution over Europe, and by mid-morning global observations from the low-earth orbiting Sentinel 5 mission. Altogether these missions will form a constellation serving the needs of the Copernicus Atmospheric Monitoring Services (CAMS). Owing to their unprecedented spatial resolution and spectral performance, TROPOMI/S5P and the subsequent Sentinel 4 and 5 missions will significantly push forward monitoring capabilities addressing anthropogenic and natural emissions of air quality-related trace gases. They will also extend the long-term datasets from past and existing UV-Vis sensors (GOME, SCIAMACHY, OMI, GOME-2, OMPS). In this presentation, we explore the potential of S5P to improve on several aspects of the monitoring of tropospheric pollutants, with a focus on the short-lived species NO2, SO2 and HCHO. Based on algorithms designed at BIRA as part of TROPOMI/S5P and S4/S5 level-2 development projects, and their application to the current OMI and GOME-2 sensors, we illustrate and discuss the expected ability of the new sensors to detect smaller scale point sources with better accuracy and selectivity. The retrieval challenges associated with higher resolution measurements are also addressed.

  6. A Methodology to Detect and Characterize Uplift Phenomena in Urban Areas Using Sentinel-1 Data

    Directory of Open Access Journals (Sweden)

    Roberta Bonì

    2018-04-01

    Full Text Available This paper presents a methodology to exploit the Persistent Scatterer Interferometry (PSI time series acquired by Sentinel-1 sensors for the detection and characterization of uplift phenomena in urban areas. The methodology has been applied to the Tower Hamlets Council area of London (United Kingdom using Sentinel-1 data covering the period 2015–2017. The test area is a representative high-urbanized site affected by geohazards due to natural processes such as compaction of recent deposits, and also anthropogenic causes due to groundwater management and engineering works. The methodology has allowed the detection and characterization of a 5 km2 area recording average uplift rates of 7 mm/year and a maximum rate of 18 mm/year in the period May 2015–March 2017. Furthermore, the analysis of the Sentinel-1 time series highlights that starting from August 2016 uplift rates began to decrease. A comparison between the uplift rates and urban developments as well as geological, geotechnical, and hydrogeological factors suggests that the ground displacements occur in a particular geological context and are mainly attributed to the swelling of clayey soils. The detected uplift could be attributed to a transient effect of the groundwater rebound after completion of dewatering works for the recent underground constructions.

  7. Comparison of 2- and 4-wavelength methods for the optical detection of sentinel lymph node

    Science.gov (United States)

    Tellier, F.; Simon, H.; Blé, F. X.; Ravelo, R.; Chabrier, R.; Steibel, J.; Rodier, J. F.; Poulet, P.

    2011-07-01

    Sentinel lymph node biopsy is the gold standard method to detect a metastatic invasion from the primary breast cancer. This method can avoid patients to be submitted to full axillary chain dissection. In this study we present and compare two near-infrared optical probes for the sentinel lymph node detection, based on the recording of scattered photons. The two setups were developed to improve the detection of the dye injected in clinical routine: the Patent Blue V dye. Herein, we present results regarding clinical ex-vivo detection of sentinel lymph node after different volume injections. We have previously published results obtained with a two-wavelength probe on phantom and animal models. However this first generation device did not completely account for the optical absorption variations from biological tissue. Thus, a second generation probe has been equipped with four wavelengths. The dye concentration computation is then more robust to measurement and tissue property fluctuations. The detection threshold of the second setup was estimated at 8.10-3μmol/L, which is about 37 times lower than the eye visibility threshold. We present here the preliminary results and demonstrate the advantages of using four wavelengths compared to two on phantom suspensions simulating the optical properties of breast tissues.

  8. [Place of indocyanine green coupled with fluorescence imaging in research of breast cancer sentinel node].

    Science.gov (United States)

    Vermersch, Charlotte; Raia Barjat, Tiphaine; Perrot, Marianne; Lima, Suzanne; Chauleur, Céline

    2016-04-01

    The sentinel node has a fundamental role in the management of early breast cancer. Currently, the double detection of blue and radioisotope is recommended. But in common practice, many centers use a single method. However, with a single detection, the risk of false negatives and the identification failure rate increase to a significant extent and the number of sentinel lymph node detected and removed is not enough. Furthermore, the tracers used until now show inconveniences. The purpose of this work is to present a new method of detection, using the green of indocyanine coupled with fluorescence imaging, and to compare it with the already existing methods. The method combined by fluorescence and isotopic is reliable, sure, of fast learning and could constitute a good strategy of detection. The major interest is to obtain a satisfactory number of sentinel nodes. The profit could be even more important for overweight patients. The fluorescence used alone is at the moment not possible. Wide ranging studies are necessary. The FLUOTECH, randomized study of 100 patients, comparing the isotopic method of double isotope technique and fluorescence, is underway to confirm these data. Copyright © 2016 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  9. The GMES Sentinel-5 mission for operational atmospheric monitoring: status and developments

    Science.gov (United States)

    Sierk, Bernd; Bezy, Jean-Loup; Caron, Jerôme; Meynard, Roland; Veihelmann, Ben; Ingmann, Paul

    2017-11-01

    Sentinel-5 is an atmospheric monitoring mission planned in the frame of the joint EU/ESA initiative Global Monitoring for Environment and Security (GMES). The objective of the mission, planned to be launched in 2020, is the operational monitoring of trace gas concentrations for atmospheric chemistry and climate applications.

  10. Sentinel node biopsy as an adjunct to limb salvage surgery for epithelioid sarcoma of the hand

    Directory of Open Access Journals (Sweden)

    Hammond Alex

    2005-06-01

    Full Text Available Abstract Background Epithelioid sarcomas of the hand are rare, high-grade tumors with a propensity for regional lymphatic spread approaching 40%. Case presentation A 54-year-old male with an epithelioid sarcoma of the palm was treated with neoadjuvant radiation, wide excision, and two-stage reconstruction. Sentinel lymph node biopsy was used to stage the patient's axilla. Sentinel node biopsy results were negative. The patient has remained free of local, regional and distant disease for the follow-up time of 16 months. Conclusion The rarity of this tumor makes definitive conclusions difficult but SLN biopsy appears to be a useful adjunct in the treatment of these sarcomas.

  11. Readiness of the Belgian network of sentinel general practitioners to deliver electronic health record data for surveillance purposes: results of survey study

    Directory of Open Access Journals (Sweden)

    Vanthomme Katrien

    2010-06-01

    Full Text Available Abstract Background In order to proceed from a paper based registration to a surveillance system that is based on extraction of electronic health records (EHR, knowledge is needed on the number and representativeness of sentinel GPs using a government-certified EHR system and the quality of EHR data for research, expressed in the compliance rate with three criteria: recording of home visits, use of prescription module and diagnostic subject headings. Methods Data were collected by annual postal surveys between 2005 and 2009 among all sentinel GPs. We tested relations between four key GP characteristics (age, gender, language community, practice organisation and use of a certified EHR system by multivariable logistic regression. The relation between EHR software package, GP characteristics and compliance with three quality criteria was equally measured by multivariable logistic regression. Results A response rate of 99% was obtained. Of 221 sentinel GPs, 55% participated in the surveillance without interruption from 2005 onwards, i.e. all five years, and 78% were participants in 2009. Sixteen certified EHR systems were used among 91% of the Dutch and 63% of the French speaking sentinel GPs. The EHR software package was strongly related to the community and only one EHR system was used by a comparable number of sentinel GPs in both communities. Overall, the prescription module was always used and home visits were usually recorded. Uniform subject headings were only sometimes used and the compliance with this quality criterion was almost exclusively related to the EHR software package in use. Conclusions The challenge is to progress towards a sentinel network of GPs delivering care-based data that are (partly extracted from well performing EHR systems and still representative for Belgian general practice.

  12. Brief behavioural surveys in routine HIV sentinel surveillance: a new tool for monitoring the HIV epidemic in Viet Nam.

    Science.gov (United States)

    Thanh, Duong Cong; Hien, Nguyen Tran; Tuan, Nguyen Anh; Ha, Hoang Thi Thanh; Thang, Pham Hong; Ha, Nguyen Thi Thanh; Tuan, Le Anh; Quang, Tran Dai; Tram, Tran Hong; Le Hai, Nguyen; Huong, Phan Thi Thu; Son, Vo Hai; Duc, Bui Hoang; Nga, Nguyen Thien; Jacka, David; Sabin, Keith

    2015-01-01

    In this report we describe a new approach in HIV sentinel surveillance that was piloted in Viet Nam in 2009 and is currently being rolled out in all provinces. It comprises a brief behavioural questionnaire added to the HIV sentinel surveillance surveys conducted routinely among people who inject drugs, female sex workers and men who have sex with men. Timely reporting of data from this system has resulted in improvements to HIV prevention efforts for most at-risk populations.

  13. The diagnostic value of adding dynamic scintigraphy to standard delayed planar imaging for sentinel node identification in melanoma patients

    DEFF Research Database (Denmark)

    Nielsen, Marie Kristina Rue; Chakera, Annette H; Hesse, Birger

    2011-01-01

    The aim of this study was to compare early dynamic imaging combined with delayed static imaging and single photon emission computed tomography (SPECT)/CT with delayed, planar, static imaging alone for sentinel node (SN) identification in melanoma patients.......The aim of this study was to compare early dynamic imaging combined with delayed static imaging and single photon emission computed tomography (SPECT)/CT with delayed, planar, static imaging alone for sentinel node (SN) identification in melanoma patients....

  14. Accident or maltreatment? Radiographic X-ray patterns in non-accidental trauma. The concept of sentinel injuries; Unfall oder Misshandlung? Radiologische Befunde beim nichtakzidentiellen Trauma. Das Konzept der ''sentinel injuries''

    Energy Technology Data Exchange (ETDEWEB)

    Hirsch, F.W.; Sorge, I.; Roth, C. [Uniklinikum Leipzig AoeR, Abteilung fuer Kinderradiologie, Leipzig (Germany); Gosemann, J.H. [Universitaetsklinikum Leipzig, Uniklinikum Leipzig AoeR, Klinik und Poliklinik fuer Kinderchirurgie, Leipzig (Germany)

    2016-05-15

    The focus of this review article is on child abuse and the radiographic pattern of X-ray findings. The radiologist should be able to recognize typical injuries resulting from child abuse. In some cases the findings are highly specific for abuse and these include metaphyseal corner fractures of the long bones in children aged up to 24 months. In other cases the fractures are not specific but highly indicative of child abuse: rib fractures, for example can be associated with child abuse in more than 50 % of the cases; however, maltreatment is difficult to diagnose without taking the entire pattern of skeletal findings into consideration so that a radiological screening of the entire skeleton is often necessary. The concept of sentinel injuries might be helpful for deciding in which cases a complete skeletal screening should be performed. In the age group up to 24 months old a complete skeletal status (with some exceptions) is recommended if one of the three sentinel injuries of rib fractures, intracranial bleeding and abdominal trauma is present. (orig.) [German] Die Kindesmisshandlung und ihre radiologischen Befundmuster sind Gegenstand dieser Uebersicht. Der Radiologe sollte in der Lage sein, typische Verletzungen als Misshandlungsfolge zu erkennen. In Einzelfaellen ist der Befund hochspezifisch fuer eine Misshandlung. Hierzu zaehlen z. B. metaphysaere Kantenabsprengungen an den langen Roehrenknochen bei bis 24 Monate alten Kindern. In anderen Faellen sind die Frakturen nicht spezifisch, aber hochsensitiv fuer das Vorliegen einer Misshandlung, z. B. bei Rippenfrakturen, die in ueber 50 % der Faelle mit einer Misshandlung assoziiert sein koennen. Die Misshandlung kann allerdings oft nur aus der Zusammenschau der unterschiedlichen Befunde, also nach Beurteilung des gesamten Skelettstatus, diagnostiziert werden. Fuer die Entscheidung, in welchen Faellen ein kompletter Skelettstatus angefertigt werden sollte, stellt sich das Konzept der ''sentinel injuries

  15. Selective sentinel lymph node biopsy in male breast cancer.

    Science.gov (United States)

    Martin-Marcuartu, J J; Alvarez-Perez, R M; Sousa Vaquero, J M; Jimenez-Hoyuela García, J M

    To evaluate the reproducibility of the sentinel lymph node (SLN) technique in male breast cancer. We retrospectively analysed 21 male patients diagnosed with breast cancer in our hospital from 2008 to 2016 with, at least, 18 months follow-up. Fifteen patients underwent selective sentinel lymph node biopsy (SLNB) following the usual protocols with peritumoral injection of 18.5-111MBq of 99m Tc-nanocoloides and acquisition of planar images 2hours after the injection. In 2 cases it was necessary to perform a SPECT/CT to locate the SLN. Immunohistochemistry and molecular techniques (OSNA) were used for their analysis. Six patients did not undergo SLNB because they had pathological nodes or distant disease at the time of diagnosis. SLNB was performed in 15 patients. The SLN was negative in 6 patients and positive in the remaining 9. Three patients with positive SLNB did not need axillary lymphadenectomy because of the low number of copies by molecular analysis OSNA. Axillary lymphadenectomy was performed in the remaining 6 patients with the result of 4 positive axillary lymphadenectomies and 2 that did not show further extension of the disease. According to our experience, SLNB in males is a reproducible, useful, safe and reliable technique which avoids unnecessary axillary lymphadenectomy and prevents the appearance of undesirable effects. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  16. Determination of aerosol optical properties for retrieval of water-leaving radiance at Roodeplaat dam relating to calibration and validation of Sentinel 2 And 3

    CSIR Research Space (South Africa)

    Faniso, Zimbini

    2017-11-01

    Full Text Available in the atmosphere. Aerosols are the strongest variables in the atmosphere by playing a major role in generating unwanted signal. Field campaign took place at Roodeplaat dam (Pretoria) relating to calibration and validation of Sentinel 2 and Sentinel 3 satellites...

  17. On detection and automatic tracking of butt weld line in thin wall pipe welding by a mobile robot with visual sensor

    International Nuclear Information System (INIS)

    Suga, Yasuo; Ishii, Hideaki; Muto, Akifumi

    1992-01-01

    An automatic pipe welding mobile robot system with visual sensor was constructed. The robot can move along a pipe, and detect the weld line to be welded by visual sensor. Moreover, in order to make an automatic welding, the welding torch can track the butt weld line of the pipes at a constant speed by rotating the robot head. Main results obtained are summarized as follows: 1) Using a proper lighting fixed in front of the CCD camera, the butt weld line of thin wall pipes can be recongnized stably. In this case, the root gap should be approximately 0.5 mm. 2) In order to detect the weld line stably during moving along the pipe, a brightness distribution measured by the CCD camera should be subjected to smoothing and differentiating and then the weld line is judged by the maximum and minimum values of the differentials. 3) By means of the basic robot system with a visual sensor controlled by a personal computer, the detection and in-process automatic tracking of a weld line are possible. The average tracking error was approximately 0.2 mm and maximum error 0.5 mm and the welding speed was held at a constant value with error of about 0.1 cm/min. (author)

  18. A Cloud-Based System for Automatic Hazard Monitoring from Sentinel-1 SAR Data

    Science.gov (United States)

    Meyer, F. J.; Arko, S. A.; Hogenson, K.; McAlpin, D. B.; Whitley, M. A.

    2017-12-01

    Despite the all-weather capabilities of Synthetic Aperture Radar (SAR), and its high performance in change detection, the application of SAR for operational hazard monitoring was limited in the past. This has largely been due to high data costs, slow product delivery, and limited temporal sampling associated with legacy SAR systems. Only since the launch of ESA's Sentinel-1 sensors have routinely acquired and free-of-charge SAR data become available, allowing—for the first time—for a meaningful contribution of SAR to disaster monitoring. In this paper, we present recent technical advances of the Sentinel-1-based SAR processing system SARVIEWS, which was originally built to generate hazard products for volcano monitoring centers. We outline the main functionalities of SARVIEWS including its automatic database interface to Sentinel-1 holdings of the Alaska Satellite Facility (ASF), and its set of automatic processing techniques. Subsequently, we present recent system improvements that were added to SARVIEWS and allowed for a vast expansion of its hazard services; specifically: (1) In early 2017, the SARVIEWS system was migrated into the Amazon Cloud, providing access to cloud capabilities such as elastic scaling of compute resources and cloud-based storage; (2) we co-located SARVIEWS with ASF's cloud-based Sentinel-1 archive, enabling the efficient and cost effective processing of large data volumes; (3) we integrated SARVIEWS with ASF's HyP3 system (http://hyp3.asf.alaska.edu/), providing functionality such as subscription creation via API or map interface as well as automatic email notification; (4) we automated the production chains for seismic and volcanic hazards by integrating SARVIEWS with the USGS earthquake notification service (ENS) and the USGS eruption alert system. Email notifications from both services are parsed and subscriptions are automatically created when certain event criteria are met; (5) finally, SARVIEWS-generated hazard products are now

  19. Breast cancer with Her-22 hormone receptor-positive neu: primary systemic treatment, sentinel node biopsy and hormone

    International Nuclear Information System (INIS)

    Lopez C, Nayara; Sanchez M, Jose Ignacio; De Santiago G, Javier

    2013-01-01

    Neoadjuvant chemotherapy is an interesting option in the therapy of some breast cancer cases. Cases in which the timing for sentinel lymph node biopsy is controversial. Co-expression of estrogen receptors and Her2/neu (cc-erbB-2) in breast cancer may imply hormone resistance, especially to tamoxifen. We present a clinic case with co-expression of estrogen receptors and Her2/neu that was treated with neoadjuvant chemotherapy and previous sentinel lymph node biopsy followed by breast tumorectomy with axillar lympha- denectomy, radiotherapy and hormonotherapy with letrozol, geserelina and trastuzumab. A good treatment response as found

  20. Comparison of subareolar injection lymphoscintigraphy with the 1-day and the 2-day protocols for the detection of sentinel lymph nodes in patients with breast cancer

    International Nuclear Information System (INIS)

    Seok, Ju-Won; Kim, In-Ju; Heo, Young-Jun; Yang, You-Jung; Choi, Yoo-Shin; Kim, Beom-Gyu; Park, Seoug-Jun

    2009-01-01

    Lymphoscintigraphy and sentinel node biopsy are used for the detection of axillary lymph node metastasis in breast cancer patients. However, currently there is no standardized technique. For the detection of axillary lymph node metastasis by lymphoscintigraphy and sentinel node biopsy, in patients with breast cancer, we compared the results of subareolar injections administered on the day of surgery (1-day protocol) with injections administered on the day before surgery (2-day protocol). This study included 412 breast cancer patients who underwent surgery between 2001 and 2004. For the 1-day protocol (1 h before surgery) 0.8 ml of Tc-99m Tin-Colloid (37 MBq) was injected in 203 in the subareolar region on the morning of the surgery. For the 2-day protocol (16 h before surgery) 0.8 ml of Tc-99m Tin-Colloid (185 MBq) was injected in 209 patients on the afternoon before surgery. Lymphoscintigraphy was performed in the supine position and sentinel node identification was performed by hand-held gamma probe during surgery. Among 203 patients with the 1-day protocol, 185 cases (91.1%) were identified by sentinel node lymphoscintigraphy, and 182 cases (89.7%) were identified by gamma probe. Among the 209 patients, in the 2-day protocol, 189 cases (90.4%) had the sentinel node identified by lymphoscintigraphy, and 182 cases (87.1%) by the gamma probe. There was no significant difference in the identification rate of the sentinel node between the 1-day and 2-day protocols by lymphoscintigraphy and the gamma probe (p>0.05, p>0.05). The results of the identification of the sentinel node by subareolar injection according to 1-day or 2-day protocol, in breast cancer patients, showed no significant differences. Because the 2-day protocol allows for an adequate amount of time to perform the lymphoscintigraphy, it is a more useful protocol for the identification of sentinel nodes in patients with breast cancer. (author)