WorldWideScience

Sample records for upper sentinel butte

  1. Geology of the upper part of the Fort Union Group (Paleocene), Williston Basin, with reference to uranium

    International Nuclear Information System (INIS)

    Jacob, A.F.

    1976-01-01

    Tabular sandstone beds in the Sentinel Butte Formation are thicker (as much as 30 m thick), more laterally extensive (more than 2 km wide in many places), and more abundant than in the Tongue River Formation. This indicates that high-sinuosity streams were more abundant where the Sentinel Butte Formation was deposited, and the streams were deeper and occupied wider meander belts, as would be found on the landward part of the delta plain. Siltstone, claystone, lignite, and a small amount of limestone were deposited on natural levees, crevasse splays, and in flood basins. The vertical arrangement of the two formations indicates a progradation of a large deltaic complex into the sea in which the Cannonball Formation was deposited. Sandstone in the Tongue River Formation classifies mostly as carbonate litharenite, and the fine fraction of the formation consists mostly of mica-group minerals, some kaolinite-group minerals, and a little montmorillonite. Sandstone in the Sentinel Butte Formation classifies mostly as volcanic litharenite, and the fine fraction consists mostly of montmorillonite, some kaolinite-group minerals, and a little of the mica-group minerals. The highest-grade uranium deposits in North Dakota are in the Sentinel Butte Formation in the area of the Little Missouri River escarpment in eastern Billings and northwestern Stark Counties. Little uranium has been found in the Tongue River Formation. Uranium may be more abundant in the Sentinel Butte Formation because of the abundance of glassy volcanic matter, which has now been largely altered to montmorillonite, and the abundance of fragments of volcanic rock. Weathering of the upper part of the Sentinel Butte Formation during formation of the Eocene paleosol in the northern Great Plains may have mobilized uranium that was deposited in the formation below the paleosol before deposition of the overlying Oligocene and younger sediment

  2. Lymphoscintigraphy detecting alterations of upper limb lymphatic flow following early sentinel lymph node biopsy in breast cancer

    Directory of Open Access Journals (Sweden)

    Sarri AJ

    2017-04-01

    surgery was performed.Results: The mean age was 54.53±9.03 years (36–73 years, the mean BMI was 27.16±4.16 kg/m2 (19.3–34.42, and the mean number of lymph nodes removed from each patient was 1.6±0.74 (1–3. There was significant difference in the time between surgery and the realization of LS (p=0.002; Mann–Whitney U test, but in an inverse relationship, the higher was the range, the smaller was the lymphatic flow, indicating a gradual reduction of lymphatic flow after surgery (Spearman’s p=0.498, with p=0.013.Conclusion: Upper limb lymphatic flow gradually decreased after the SLNB and conservative breast surgery in this study, but these results are exploratory because of the small sample size. Further studies are needed to confirm and to investigate more in depth these findings. Keywords: lymph node sentinel biopsy, lymphoscintigraphy, nuclear medicine, lymphedema, breast cancer

  3. Interview with Gavin Butt

    DEFF Research Database (Denmark)

    Hasse Jørgensen, Stina; Alexandra Sofie, Jönsson

    2008-01-01

    We have interviewed Gavin Butt about his research interest in the cross-field between performance and performativity in the visual arts: queer theory, queer cultures and their histories, post-second world war U.S. art, contemporary art and critical theory.......We have interviewed Gavin Butt about his research interest in the cross-field between performance and performativity in the visual arts: queer theory, queer cultures and their histories, post-second world war U.S. art, contemporary art and critical theory....

  4. Sentinel Mining

    DEFF Research Database (Denmark)

    Middelfart, Morten

    business users about potential changes to Key Performance Indicators (KPIs) and thereby facilitate corrective action before such a change becomes a reality. Specifically, sentinels are rule relationships at the schema level in a multidimensional data cube. These relationships represent changes over time...... in certain measures that are followed by a change in a user defined critical measure, typically a KPI. An important property of a sentinel is bi-directionality, which means that the change relationship holds in the complement direction, since a sentinel with the bi-directional property has a higher chance...

  5. Sentinel Network

    Science.gov (United States)

    The Sentinel Network is an integrated, electronic, national medical product safety initiative that compiles information about the safe and effective use of medical products accessible to patients and healthcare practitioners.

  6. SENTINEL EVENTS

    Directory of Open Access Journals (Sweden)

    Andrej Robida

    2004-09-01

    Full Text Available Background. The Objective of the article is a two year statistics on sentinel events in hospitals. Results of a survey on sentinel events and the attitude of hospital leaders and staff are also included. Some recommendations regarding patient safety and the handling of sentinel events are given.Methods. In March 2002 the Ministry of Health introduce a voluntary reporting system on sentinel events in Slovenian hospitals. Sentinel events were analyzed according to the place the event, its content, and root causes. To show results of the first year, a conference for hospital directors and medical directors was organized. A survey was conducted among the participants with the purpose of gathering information about their view on sentinel events. One hundred questionnaires were distributed.Results. Sentinel events. There were 14 reports of sentinel events in the first year and 7 in the second. In 4 cases reports were received only after written reminders were sent to the responsible persons, in one case no reports were obtained. There were 14 deaths, 5 of these were in-hospital suicides, 6 were due to an adverse event, 3 were unexplained. Events not leading to death were a suicide attempt, a wrong side surgery, a paraplegia after spinal anaesthesia, a fall with a femoral neck fracture, a damage of the spleen in the event of pleural space drainage, inadvertent embolization with absolute alcohol into a femoral artery and a physical attack on a physician by a patient. Analysis of root causes of sentinel events showed that in most cases processes were inadequate.Survey. One quarter of those surveyed did not know about the sentinel events reporting system. 16% were having actual problems when reporting events and 47% beleived that there was an attempt to blame individuals. Obstacles in reporting events openly were fear of consequences, moral shame, fear of public disclosure of names of participants in the event and exposure in mass media. The majority of

  7. Optimization and Prediction of Angular Distortion and Weldment Characteristics of TIG Square Butt Joints

    Science.gov (United States)

    Narang, H. K.; Mahapatra, M. M.; Jha, P. K.; Biswas, P.

    2014-05-01

    Autogenous arc welds with minimum upper weld bead depression and lower weld bead bulging are desired as such welds do not require a second welding pass for filling up the upper bead depressions (UBDs) and characterized with minimum angular distortion. The present paper describes optimization and prediction of angular distortion and weldment characteristics such as upper weld bead depression and lower weld bead bulging of TIG-welded structural steel square butt joints. Full factorial design of experiment was utilized for selecting the combinations of welding process parameter to produce the square butts. A mathematical model was developed to establish the relationship between TIG welding process parameters and responses such as upper bead width, lower bead width, UBD, lower bead height (bulging), weld cross-sectional area, and angular distortions. The optimal welding condition to minimize UBD and lower bead bulging of the TIG butt joints was identified.

  8. FIRE HAZARDS ANALYSIS - BUSTED BUTTE

    International Nuclear Information System (INIS)

    Longwell, R.; Keifer, J.; Goodin, S.

    2001-01-01

    The purpose of this fire hazards analysis (FHA) is to assess the risk from fire within individual fire areas at the Busted Butte Test Facility and to ascertain whether the DOE fire safety objectives are met. The objective, identified in DOE Order 420.1, Section 4.2, is to establish requirements for a comprehensive fire and related hazards protection program for facilities sufficient to minimize the potential for: (1) The occurrence of a fire related event. (2) A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of employees. (3) Vital DOE programs suffering unacceptable interruptions as a result of fire and related hazards. (4) Property losses from a fire and related events exceeding limits established by DOE. Critical process controls and safety class systems being damaged as a result of a fire and related events

  9. BioSentinel

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced Exploration Systems' (AES) BioSentinel project will develop, prototype, integrate, test, and prepare for the first spaceflight mission of a broadly...

  10. Sentinels for snow science

    Science.gov (United States)

    Gascoin, S.; Grizonnet, M.; Baba, W. M.; Hagolle, O.; Fayad, A.; Mermoz, S.; Kinnard, C.; Fatima, K.; Jarlan, L.; Hanich, L.

    2017-12-01

    Current spaceborne sensors do not allow retrieving the snow water equivalent in mountain regions, "the most important unsolved problem in snow hydrology" (Dozier, 2016). While the NASA is operating an airborne mission to survey the SWE in the western USA, elsewhere, however, snow scientists and water managers do not have access to routine SWE measurements at the scale of a mountain range. In this presentation we suggest that the advent of the Copernicus Earth Observation programme opens new perspectives to address this issue in mountain regions worldwide. The Sentinel-2 mission will provide global-scale multispectral observations at 20 m resolution every 5-days (cloud permitting). The Sentinel-1 mission is already imaging the global land surface with a C-band radar at 10 m resolution every 6 days. These observations are unprecedented in terms of spatial and temporal resolution. However, the nature of the observation (radiometry, wavelength) is in the continuity of previous and ongoing missions. As a result, it is relatively straightforward to re-use algorithms that were developed by the remote sensing community over the last decades. For instance, Sentinel-2 data can be used to derive maps of the snow cover extent from the normalized difference snow index, which was initially proposed for Landsat. In addition, the 5-days repeat cycle allows the application of gap-filling algorithms, which were developed for MODIS based on the temporal dimension. The Sentinel-1 data can be used to detect the wet snow cover and track melting areas as proposed for ERS in the early 1990's. Eventually, we show an example where Sentinel-2-like data improved the simulation of the SWE in the data-scarce region of the High Atlas in Morocco through assimilation in a distributed snowpack model. We encourage snow scientists to embrace Sentinel-1 and Sentinel-2 data to enhance our knowledge on the snow cover dynamics in mountain regions.

  11. Sentinel node detection in pre-operative axillary staging.

    Science.gov (United States)

    Trifirò, Giuseppe; Viale, Giuseppe; Gentilini, Oreste; Travaini, Laura Lavinia; Paganelli, Giovanni

    2004-06-01

    The concept of sentinel lymph node biopsy in breast cancer surgery is based on the fact that the tumour drains in a logical way via the lymphatic system, from the first to upper levels. Since axillary node dissection does not improve the prognosis of patients with breast cancer, sentinel lymph node biopsy might replace complete axillary dissection for staging of the axilla in clinically N0 patients. Sentinel lymph node biopsy would represent a significant advantage as a minimally invasive procedure, considering that about 70% of patients are found to be free from metastatic disease, yet axillary node dissection can lead to significant morbidity. Subdermal or peritumoural injection of small aliquots (and very low activity) of radiotracer is preferred to intratumoural administration, and (99m)Tc-labelled colloids with most of the particles in the 100-200 nm size range would be ideal for radioguided sentinel node biopsy in breast cancer. The success rate of radioguidance in localising the sentinel lymph node in breast cancer surgery is about 97% in institutions where a high number of procedures are performed, and the success rate of lymphoscintigraphy in sentinel node detection is about 100%. The sentinel lymph node should be processed for intraoperative frozen section examination in its entirety, based on conventional histopathology and, when necessary, immune staining with anti-cytokeratin antibody. Nowadays, lymphoscintigraphy is a useful procedure in patients with different clinical evidence of breast cancer.

  12. 77 FR 12106 - Kapka Butte Sno-Park Construction

    Science.gov (United States)

    2012-02-28

    ... DEPARTMENT OF TRANSPORTATION Federal Highway Administration Kapka Butte Sno-Park Construction... Construction project. SUMMARY: The FHWA is issuing this notice to advise the public that the FHWA is officially designated as the Joint-Lead Agency pursuant to 23 U.S.C. 139(c)(1) for the Kapka Butte Sno-Park Construction...

  13. Validation of sentinel data.

    NARCIS (Netherlands)

    Bartelds, A.I.M.

    1993-01-01

    The Dutch Sentinel Practice Network, "de Peilstations" started in 1970. The purpose of this network is to gain a better insight into the epidemiology of a number of illnesses and conditions as they are presented to the general practitioner. The network is sponsored by the Ministry of Welfare, Public

  14. Sentinel-3 for Science

    Science.gov (United States)

    Benveniste, J.; Regner, P.; Desnos, Y. L.

    2015-12-01

    The Scientific Exploitation of Operational Mission (SEOM) programme element (http://seom.esa.int/) is part of the ESA's Fourth Earth Observation Envelope Programme (2013-2017). The prime objective is to federate, support and expand the international research community that the ERS, ENVISAT and the Envelope programmes have built up over the last 25 years. It aims to further strengthen the leadership of the European Earth Observation research community by enabling them to extensively exploit future European operational EO missions. SEOM is enabling the science community to address new scientific research that are opened by free and open access to data from operational EO missions. The Programme is based on community-wide recommendations for actions on key research issues, gathered through a series of international thematic workshops and scientific user consultation meetings such as the Sentinel-3 for Science Workshop held last June in Venice, Italy (see http://seom.esa.int/S3forScience2015). The 2015 SEOM work plan includes the launch of new R&D studies for scientific exploitation of the Sentinels, the development of open-source multi-mission scientific toolboxes, the organization of advanced international training courses, summer schools and educational materials, as well as activities for promoting the scientific use of EO data, also via the organization of Workshops. This paper will report the recommendations from the International Scientific Community concerning the Sentinel-3 Scientific Exploitation, as expressed in Venice, keeping in mind that Sentinel-3 is an operational mission to provide operational services (see http://www.copernicus.eu).

  15. Sutter Buttes-the lone volcano in California's Great Valley

    Science.gov (United States)

    Hausback, Brain P.; Muffler, L.J. Patrick; Clynne, Michael A.

    2011-01-01

    The volcanic spires of the Sutter Buttes tower 2,000 feet above the farms and fields of California's Great Valley, just 50 miles north-northwest of Sacramento and 11 miles northwest of Yuba City. The only volcano within the valley, the Buttes consist of a central core of volcanic domes surrounded by a large apron of fragmental volcanic debris. Eruptions at the Sutter Buttes occurred in early Pleistocene time, 1.6 to 1.4 million years ago. The Sutter Buttes are not part of the Cascade Range of volcanoes to the north, but instead are related to the volcanoes in the Coast Ranges to the west in the vicinity of Clear Lake, Napa Valley, and Sonoma Valley.

  16. Sentinel-3 For Land Applications

    Science.gov (United States)

    Goryl, Philippe; Gobron, Nadine; Mecklenburg, Susanne; Donlon, Craig; Bouvet, Marc; Buongiorno, Alessandra; Wilson, Hilary

    2016-07-01

    The Copernicus Programme, being Europe's Earth Observation and Monitoring Programme led by the European Union, aims to provide, on a sustainable basis, reliable and timely services related to environmental and security issues. The Sentinel-3 mission forms part of the Copernicus Space Component. Its main objectives, building on the heritage and experience of the European Space Agency's (ESA) ERS and ENVISAT missions, are to measure sea-surface topography, sea- and land-surface temperature and ocean- and land-surface colour in support of ocean forecasting systems, and for environmental and climate monitoring. The series of Sentinel-3 satellites will ensure global, frequent and near-real time ocean, ice and land monitoring, with the provision of observation data in a routine, long-term (up to 20 years of operations) and continuous fashion, with a consistent quality and a high level of reliability and availability. The launch of Sentinel-3 was successful last February 2016. The Sentinel-3 missions are jointly operated by ESA and EUMETSAT. ESA will be responsible for the operations, maintenance and evolution of the Sentinel-3 ground segment on land related products and EUMETSAT on the marine products and the satellite monitoring and control. All facilities supporting the Sentinel-3 operations are in place. The Sentinel-3 ground segment systematically acquires, processes and distributes a set of pre-defined core data products to the users. For a detailed description of the core data products please see https://earth.esa.int/web/sentinel/missions/sentinel-3/data-products. On request from the European Commission, ESA and EUMETSAT are presently assessing the possibility to include further core data products, in particular on aerosol optical depth, fire monitoring and synergistic products over land. This paper will provide an update on the status of the mission operations after the initial months in orbit and provide in particular an overview on the status of the Sentinel-3

  17. Creep failure analysis of butt welded tubes

    International Nuclear Information System (INIS)

    Browne, R.J.; Parker, J.D.; Walters, D.J.

    1981-01-01

    As part of a major research programme to investigate the influence of butt welds on the life expectancy of tubular components, a series of internal-pressure, stress-rupture tests have been carried out. Thick walled 1/2Cr 1/2Mo 1/4V tube specimens were welded with mild steel, 1Cr 1/2Mo steel, 2 1/4Cr 1Mo steel or nominally matching 1/2Cr 1/2Mo 1/4V steel to give a wide range of weld metal creep strengths relative to the parent tube. The weldments were tested at 565 0 C at two values of internal pressure, and gave failure lives of up to 44,000 hrs. Finite element techniques have been used to determine the stationary state stress distribution in the weldment which was represented by a three material model. Significant stress redistribution was indicated and these results enabled the position and orientation of cracking and the rupture life to be predicted. The theoretical and experimental results have been used to highlight the limitations of current design methods which are based on the application of the mean diameter hoop stress to the parent material stress rupture data. (author)

  18. High risk of non-sentinel node metastases in a group of breast cancer patients with micrometastases in the sentinel node.

    Science.gov (United States)

    Tvedskov, Tove Filtenborg; Jensen, Maj-Britt; Lisse, Ida Marie; Ejlertsen, Bent; Balslev, Eva; Kroman, Niels

    2012-11-15

    Axillary lymph node dissection (ALND) in breast cancer patients with positive sentinel nodes is under debate. We aimed to establish two models to predict non-sentinel node (NSN) metastases in patients with micrometastases or isolated tumor cells (ITC) in sentinel nodes, to guide the decision for ALND. A total of 1,577 breast cancer patients with micrometastases and 304 with ITC in sentinel nodes, treated by sentinel lymph node dissection and ALND in 2002-2008 were identified in the Danish Breast Cancer Cooperative Group database. Risk of NSN metastases was calculated according to clinicopathological variables in a logistic regression analysis. We identified tumor size, proportion of positive sentinel nodes, lymphovascular invasion, hormone receptor status and location of tumor in upper lateral quadrant of the breast as risk factors for NSN metastases in patients with micrometastases. A model based on these risk factors identified 5% of patients with a risk of NSN metastases on nearly 40%. The model was however unable to identify a subgroup of patients with a very low risk of NSN metastases. Among patients with ITC, we identified tumor size, age and proportion of positive sentinel nodes as risk factors. A model based on these risk factors identified 32% of patients with risk of NSN metastases on only 2%. Omission of ALND would be acceptable in this group of patients. In contrast, ALND may still be beneficial in the subgroup of patients with micrometastases and a high risk of NSN metastases. Copyright © 2012 UICC.

  19. Geographic patterns of cigarette butt waste in the urban environment.

    Science.gov (United States)

    Marah, Maacah; Novotny, Thomas E

    2011-05-01

    This reports the initial phase of a study to quantify the spatial pattern of cigarette butt waste in an urban environment. Geographic Information Systems (GIS) was used to create a weighted overlay analysis model which was then applied to the locations of businesses where cigarettes are sold or are likely to be consumed and venues where higher concentrations of butts may be deposited. The model's utility was tested using a small-scale litter audit in three zip codes of San Diego, California. We found that cigarette butt waste is highly concentrated around businesses where cigarettes are sold or consumed. The mean number of butts for predicted high waste sites was 38.1 (SD 18.87), for predicted low waste sites mean 4.8 (SD 5.9), psales and consumption. A GIS and weighted overlay model may be a useful tool in predicting urban locations of greater and lesser amounts of cigarette butt waste. These data can in turn be used to develop economic cost studies and plan mitigation strategies in urban communities.

  20. Bali Cattle Carcass Characteristic of Different Butt Shape Condition

    Science.gov (United States)

    Hafid, H.; Nuraini; Inderawati; Kurniawan, W.

    2018-02-01

    Carcass was main product on cattle slaughtering which contain beef for human consumption and it has high nutritional and economical value. Carcass production on cattle has been influenced by several factors, such as cattle breed, feed, and body conformation. Cattle Butt Shape was one of part cattle body conformation which allegedly has have positive correlation on produced carcass. This research was aimed to evaluate Butt Shape condition influenced on Bali cattle carcass characteristic. The research was using Bali cattle which slaughter in Kendari Slaughtering House (Rumah Potong Hewan/RPH - Kendari). The observation includes weighing, and measuring parts of carcass was conducted on 60 heads of Halal process slaughtered Bali cattle which traditionally maintained. The research parameters were carcass productivity parameters i.e: slaughtering weight, carcass weight and length, leg length and circumstances. Obtained data were analyzed using Complete Randomized Design and post hoc analyzed using Least Significant Different if have any influence. The research result showed that cattle Butt Shape condition have significant (pBali cattle carcass productivity parameters. Butt shape with B category was result the best carcass productivity compare the others, while C category was better than D. It can be concluded that body and carcass weight were linearly influenced by cattle butt shape.

  1. [Even cigarette butts can impact environment and health: preliminary considerations].

    Science.gov (United States)

    Martino, Gianrocco; Gorini, Giuseppe; Chellini, Elisabetta

    2013-01-01

    In Italy, every year about 72 billion of cigarette butts are thrown away in the environment. Cigarette butts represent 50% of the wastes of urban areas (parks, roads) in the world, and 40% of Mediterranean Sea wastes. In particular, total polluting load is constituted of 1,872 Bq millions of Polonium-210, assuming 75 mBq per cigarette butt, and 1,800 tons of volatile organic compounds. As a matter of fact, according to several surveys, cigarette butts are considered by smokers and non-smokers as a common and acceptable waste in the environment. In 2008, European Union issued a Directive on wastes considering the «extended producer responsibility» (i.e., every industry is liable for costs of collection, transport and disposal of its own products). In October 2012, the Italian Parliament proposed a bill that classifies cigarette butts as special wastes in the frame of this responsibility. It could be interesting in the future to follow the legislative process of that bill in the Italian Parliament in order to show how strong it will be supported.

  2. Tidal Creek Sentinel Habitat Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Ecological Research, Assessment and Prediction's Tidal Creeks: Sentinel Habitat Database was developed to support the National Oceanic and Atmospheric...

  3. Geology of Gable Mountain-Gable Butte Area

    International Nuclear Information System (INIS)

    Fecht, K.R.

    1978-09-01

    Gable Mountain and Gable Butte are two ridges which form the only extensive outcrops of the Columbia River Basalt Group in the central portion of the Pasco Basin. The Saddle Mountains Basalt and two interbedded sedimentary units of the Ellensburg Formation crop out on the ridges. These include, from oldest to youngest, the Asotin Member (oldest), Esquatzel Member, Selah Interbed, Pomona Member, Rattlesnake Ridge Interbed, and Elephant Mountain Member (youngest). A fluvial plain composed of sediments from the Ringold and Hanford (informal) formations surrounds these ridges. The structure of Gable Mountain and Gable Butte is dominated by an east-west-trending major fold and northwest-southeast-trending parasitic folds. Two faults associated with the uplift of these structures were mapped on Gable Mountain. The geomorphic expression of the Gable Mountain-Gable Butte area resulted from the comlex folding and subsequent scouring by post-basalt fluvial systems

  4. 78 FR 21582 - Revisions to the California State Implementation Plan, Butte County Air Quality Management...

    Science.gov (United States)

    2013-04-11

    ... the California State Implementation Plan, Butte County Air Quality Management District and Sacramento Metropolitan Air Quality Management District AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule. SUMMARY: EPA is proposing to approve revisions to the Butte County Air Quality Management...

  5. Equipment for Preparing Pipeline Position Butts for Welding

    Directory of Open Access Journals (Sweden)

    Lobanov L.M.

    2015-09-01

    Full Text Available The results of developments of the Ye.O.Paton Electric Welding Institute and its specialized departments on the designing national equipment models for preparation during the assembly the edges and butt ends of pipeline position butts with the diameter from 14 up to 159 mm, repair and modernization of power engineering objects, including the power units of nuclear and heat electric stations, in chemical and machine building, at enterprises of oil-gas complex and other branches of industry are presented.

  6. 75 FR 53714 - Stainless Steel Butt-Weld Pipe Fittings From Japan, Korea, and Taiwan

    Science.gov (United States)

    2010-09-01

    ...)] Stainless Steel Butt-Weld Pipe Fittings From Japan, Korea, and Taiwan AGENCY: United States International... stainless steel butt-weld pipe fittings from Japan, Korea, and Taiwan. SUMMARY: The Commission hereby gives... butt-weld pipe fittings from Japan, Korea, and Taiwan would be likely to lead to continuation or...

  7. Investigation and control of factors influencing resistance upset butt welding.

    NARCIS (Netherlands)

    Kerstens, N.F.H.

    2010-01-01

    The purpose of this work is to investigate the factors influencing the resistance upset butt welding process to obtain an understanding of the metal behaviour and welding process characteristics, so that new automotive steels can be welded with reduced development time and fewer failures in

  8. Butt-welding technology for double walled Polyethylene pipe

    International Nuclear Information System (INIS)

    Lee, Bo-Young; Kim, Jae-Seong; Lee, Sang-Yul; Kim, Yeong K.

    2012-01-01

    Highlights: ► We developed a butt welding apparatus for doubled walled Polyethylene pipe. ► We design the welding process by analyzing thermal behaviors of the material. ► We performed the welding and tested the welded structural performances. ► We also applied the same technology to PVC pipes. ► We verified the butt welding was successful and effective for the pipes with irregular sections. -- Abstract: In this study, mechanical analyses of a butt welding technology for joining Polyethylene pipe are presented. The pipe had unique structure with double wall, and its section topology was not flat. For an effective repair of leakage and replacements of the pipe, the butt welding technology was developed and tested. For the material characterizations, thermodynamic analyses such as thermal gravimetric analysis and differential scanning calorimetry were performed. Based on the test results, the process temperature and time were determined to ensure safe joining of the pipes using a hot plate apparatus. The welding process was carefully monitored by measuring the temperature. Then, the joined pipes were tested by various methods to evaluate the quality. The analyses results showed the detail process mechanism during the joining process, and the test results demonstrated the successful application of the technology to the sewage pipe repairs.

  9. Application Regarding the Butt-Welding Through Intermediate Melting

    Directory of Open Access Journals (Sweden)

    Tudorel Ene

    2006-10-01

    Full Text Available It consists in presenting butt welding procedure through intermediate melting and its usage for manufacturing cutting tools type drill, tap screw, reamer by welding the active part (made of high-speed steel to the tool tail (made of unalloyed steel wit low carbon.

  10. ANSYS Simulation of Residual Strains in Butt-welded Joints

    Directory of Open Access Journals (Sweden)

    A. Atroshenko

    2014-07-01

    Full Text Available The effect of thermal-strain cycle on residual strains in thin-walled circular seams of cylindrical shells using TIG butt welds was studied. Estimates were calculated using numerical modelling. The structure was made of corrosion-resistant austenitic steels.

  11. Regulating the disposal of cigarette butts as toxic hazardous waste.

    Science.gov (United States)

    Barnes, Richard L

    2011-05-01

    The trillions of cigarette butts generated each year throughout the world pose a significant challenge for disposal regulations, primarily because there are millions of points of disposal, along with the necessity to segregate, collect and dispose of the butts in a safe manner, and cigarette butts are toxic, hazardous waste. There are some hazardous waste laws, such as those covering used tyres and automobile batteries, in which the retailer is responsible for the proper disposal of the waste, but most post-consumer waste disposal is the responsibility of the consumer. Concepts such as extended producer responsibility (EPR) are being used for some post-consumer waste to pass the responsibility and cost for recycling or disposal to the manufacturer of the product. In total, 32 states in the US have passed EPR laws covering auto switches, batteries, carpet, cell phones, electronics, fluorescent lighting, mercury thermostats, paint and pesticide containers, and these could be models for cigarette waste legislation. A broader concept of producer stewardship includes EPR, but adds the consumer and the retailer into the regulation. The State of Maine considered a comprehensive product stewardship law in 2010 that is a much better model than EPR. By using either EPR or the Maine model, the tobacco industry will be required to cover the cost of collecting and disposing of cigarette butt waste. Additional requirements included in the Maine model are needed for consumers and businesses to complete the network that will be necessary to maximise the segregation and collection of cigarette butts to protect the environment.

  12. Aluminum 6060-T6 friction stir welded butt joints: fatigue resistance with different tools and feed rates

    International Nuclear Information System (INIS)

    Baragetti, S.; D'Urso, G.

    2014-01-01

    The fatigue behavior of AA6060-T6 friction stir welded butt joints was investigated. The joints were produced by using both a standard and a threaded tri-flute cylindrical-tool with flat shoulder. The friction stir welding process was carried out using different feed rates. Preliminary tensile tests, micrograph analyses and hardness profile measurements across the welds were carried out. Welded and unwelded fatigue samples were tested under axial loading (R = 0.1) with upper limits of 10 4 and 10 5 cycles, using threaded and unthreaded (standard) tools at different feed rates. The best tensile and fatigue performance was obtained using the standard tool at low feed rate.

  13. GAP WIDTH STUDY IN LASER BUTT-WELDING

    DEFF Research Database (Denmark)

    Gong, Hui; Olsen, Flemming Ove

    power : 2 and 2.6 kW and the focal point position : 0 and -1.2 mm. Quality of all the butt welds are destructively tested according to ISO 13919-1.Influences of the variable process parameters to the maximum allowable gap width are observed as (1) the maximum gap width is inversely related......In this paper the maximum allowable gap width in laser butt-welding is intensively studied. The gap width study (GWS) is performed on the material of SST of W1.4401 (AISI 316) under various welding conditions, which are the gap width : 0.00-0.50 mm, the welding speed : 0.5-2.0 m/min, the laser...... to the welding speed, (2) the larger laser power leads to the bigger maximum allowable gap width and (3) the focal point position has very little influence on the maximum gap width....

  14. Investigation and control of factors influencing resistance upset butt welding.

    OpenAIRE

    Kerstens, N.F.H.

    2010-01-01

    The purpose of this work is to investigate the factors influencing the resistance upset butt welding process to obtain an understanding of the metal behaviour and welding process characteristics, so that new automotive steels can be welded with reduced development time and fewer failures in production. In principle the welding process is rather simple, the materials to be joined are clamped between two electrodes and pressed together. Because there is an interface present with a higher resist...

  15. The Western Environmental Technology Office (WETO), Butte, Montana. Technology summary

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    The Western Environmental Technology Office (WETO) is a multi-purpose engineering test facility located in Butte, Montana, and is managed by MSE, Inc. WETO seeks to contribute to environmental research by emphasizing projects to develop heavy metals removal and recovery processes, thermal vitrification systems, and waste minimization/pollution prevention technologies. WETO`s environmental technology research and testing activities focus on the recovery of usable resources from waste. In one of WETO`s areas of focus, groundwater contamination, water from the Berkeley Pit, located near the WETO site, is being used in demonstrations directed toward the recovery of potable water and metal from the heavy metal-bearing water. The Berkeley Pit is part of an inactive copper mine near Butte that was once part of the nation`s largest open-pit mining operation. The Pit contains approximately 25 billion gallons of Berkeley Pit groundwater and surface water containing many dissolved minerals. As part of DOE/OST`s Resource Recovery Project (RRP), technologies are being demonstrated to not only clean the contaminated water but to recover metal values such as copper, zinc, and iron with an estimated gross value of more than $100 million. When recovered, the Berkeley Pit waters could benefit the entire Butte valley with new water resources for fisheries, irrigation, municipal, and industrial use. At WETO, the emphasis is on environmental technology development and commercialization activities, which will focus on mine cleanup, waste treatment, resource recovery, and water resource management.

  16. The Western Environmental Technology Office (WETO), Butte, Montana. Technology summary

    International Nuclear Information System (INIS)

    1996-03-01

    The Western Environmental Technology Office (WETO) is a multi-purpose engineering test facility located in Butte, Montana, and is managed by MSE, Inc. WETO seeks to contribute to environmental research by emphasizing projects to develop heavy metals removal and recovery processes, thermal vitrification systems, and waste minimization/pollution prevention technologies. WETO's environmental technology research and testing activities focus on the recovery of usable resources from waste. In one of WETO's areas of focus, groundwater contamination, water from the Berkeley Pit, located near the WETO site, is being used in demonstrations directed toward the recovery of potable water and metal from the heavy metal-bearing water. The Berkeley Pit is part of an inactive copper mine near Butte that was once part of the nation's largest open-pit mining operation. The Pit contains approximately 25 billion gallons of Berkeley Pit groundwater and surface water containing many dissolved minerals. As part of DOE/OST's Resource Recovery Project (RRP), technologies are being demonstrated to not only clean the contaminated water but to recover metal values such as copper, zinc, and iron with an estimated gross value of more than $100 million. When recovered, the Berkeley Pit waters could benefit the entire Butte valley with new water resources for fisheries, irrigation, municipal, and industrial use. At WETO, the emphasis is on environmental technology development and commercialization activities, which will focus on mine cleanup, waste treatment, resource recovery, and water resource management

  17. Sentinel-3 SAR Altimetry Toolbox

    Science.gov (United States)

    Benveniste, Jerome; Lucas, Bruno; DInardo, Salvatore

    2015-04-01

    The prime objective of the SEOM (Scientific Exploitation of Operational Missions) element is to federate, support and expand the large international research community that the ERS, ENVISAT and the Envelope programmes have build up over the last 20 years for the future European operational Earth Observation missions, the Sentinels. Sentinel-3 builds directly on a proven heritage of ERS-2 and Envisat, and CryoSat-2, with a dual-frequency (Ku and C band) advanced Synthetic Aperture Radar Altimeter (SRAL) that provides measurements at a resolution of ~300m in SAR mode along track. Sentinel-3 will provide exact measurements of sea-surface height along with accurate topography measurements over sea ice, ice sheets, rivers and lakes. The first of the two Sentinels is expected to be launched in early 2015. The current universal altimetry toolbox is BRAT (Basic Radar Altimetry Toolbox) which can read all previous and current altimetry mission's data, but it does not have the capabilities to read the upcoming Sentinel-3 L1 and L2 products. ESA will endeavour to develop and supply this capability to support the users of the future Sentinel-3 SAR Altimetry Mission. BRAT is a collection of tools and tutorial documents designed to facilitate the processing of radar altimetry data. This project started in 2005 from the joint efforts of ESA (European Space Agency) and CNES (Centre National d'Etudes Spatiales), and it is freely available at http://earth.esa.int/brat. The tools enable users to interact with the most common altimetry data formats, the BratGUI is the front-end for the powerful command line tools that are part of the BRAT suite. BRAT can also be used in conjunction with Matlab/IDL (via reading routines) or in C/C++/Fortran via a programming API, allowing the user to obtain desired data, bypassing the data-formatting hassle. BRAT can be used simply to visualise data quickly, or to translate the data into other formats such as netCDF, ASCII text files, KML (Google Earth

  18. Sentinel node concept in breast cancer

    International Nuclear Information System (INIS)

    Kiricuta, I.C.

    2000-01-01

    Background/purpose: It seems that there exists a specific lymph node center called sentinel node (SN) which appears to be the primary site of metastases. The sentinel node concept (SNC) is fundamentally based on the orderly progression of tumor cells within the lymphatic system. It is the most important new concept in surgical and radiation oncology. The purpose is to present the biological significance, the diagnostic and clinical basis of the sentinel node concept in breast cancer patients. Material and methods: Lymphoscintigraphy and gamma probe biopsy is necessary to show predictable lymph flow to the regional sentinel node, to multiple sentinel nodes or unpredictable lymph flow to extra-regional sentinel nodes and for performing sentinel node procedure. The standard protocol for the evaluation of the sentinel node metastases consists of extensive histopathological investigation including step Hematoxylin and Eosin (H and E) stained sections and immunohistochemistry. Results: A high rate of success of the identification of the sentinel node for breast cancer was reported. The presence or absence of metastasis in this node is a very accurate predictor of overall nodal status. The temptation to examine the sentinel node with the greatest possible degree of accuracy highlights one of the major problems related to sentinel node biopsy. The success of the sentinel node procedure depends primarily on the adequate functional capacity necessary for sufficient uptake to ensure the accurate identification. In negative sentinel-node patients a complete axillary lymph node dissection is avoidable. In sentinel-node positive patients and clinically negative patients a postoperative radiotherapy would permit an adequate tumor control. The last 2-procedures permit a low morbidity. In the actual TNM classification it was recently introduced a definition of a 'pN0' patient based on sentinel node biopsy. New target volumes are defined for adjuvant radiotherapy or lymphatic basins

  19. Independent System Calibration of Sentinel-1B

    Directory of Open Access Journals (Sweden)

    Marco Schwerdt

    2017-05-01

    Full Text Available Sentinel-1B is the second of two C-Band Synthetic Aperture Radar (SAR satellites of the Sentinel-1 mission, launched in April 2016—two years after the launch of the first satellite, Sentinel-1A. In addition to the commissioning of Sentinel-1B executed by the European Space Agency (ESA, an independent system calibration was performed by the German Aerospace Center (DLR on behalf of ESA. Based on an efficient calibration strategy and the different calibration procedures already developed and applied for Sentinel-1A, extensive measurement campaigns were executed by initializing and aligning DLR’s reference targets deployed on the ground. This paper describes the different activities performed by DLR during the Sentinel-1B commissioning phase and presents the results derived from the analysis and the evaluation of a multitude of data takes and measurements.

  20. Intraoperative Sentinel Lymph Node Evaluation

    DEFF Research Database (Denmark)

    Shaw, Richard; Christensen, Anders; Java, Kapil

    2016-01-01

    BACKGROUND: Intraoperative analysis of sentinel lymph nodes would enhance the care of early-stage oral squamous cell carcinoma (OSCC). We determined the frequency and extent of cytokeratin 19 (CK19) expression in OSCC primary tumours and surrounding tissues to explore the feasibility of a "clinic......-ready" intraoperative diagnostic test (one step nucleic acid amplification-OSNA, sysmex). METHODS: Two cohorts were assembled: cohort 1, OSCC with stage and site that closely match cases suitable for sentinel lymph node biopsy (SLNB); cohort 2, HNSCC with sufficient fresh tumour tissue available for the OSNA assay (>50......% of tumours. Discordance between different techniques indicated that OSNA was more sensitive than qRT-PCR or RNA-ISH, which in turn were more sensitive than IHC. OSNA results showed CK19 expression in 80% of primary cases, so if used for diagnosis of lymph node metastasis would lead to a false-negative result...

  1. Methodology of sentinel node detection

    International Nuclear Information System (INIS)

    Maublant, J.

    2000-01-01

    The isotopic localisation of the sentinel node, i.e., the first functional lymph node in a tumor basin, is probably the fastest growing field ever experienced in nuclear medicine. Although based on the simple concept of the lymphatic migration of Tc-labeled colloids, the choice of the optimal technique remains controversial. We review and discuss the role of the colloids, of the site of injection, of the injected volume, of early imaging and of the colorimetric approach. Initially applied to melanoma and breast cancer, the sentinel node detection is now tested in other types of cancer such as lung, colon and prostate. It could become one of the leading tools in minimally invasive surgical oncology. The nuclear medicine physician has to remain aware of the rapid evolutions in this field in order to be able to answer to a rapidly growing demand. (author)

  2. Copernicus POD Service: Ready for Sentinel-3

    Science.gov (United States)

    Peter, H.; Fernández, J.; Escobar, D.; Féménias, P.; Flohrer, C.; Otten, M.

    2015-12-01

    The Copernicus POD Service is part of the Copernicus PDGS Ground Segment of the Sentinel missions. A GMV-led consortium is operating the Copernicus POD Service being in charge of generating precise orbital products and auxiliary data files for their use as part of the processing chains of the respective Sentinel PDGS. The Sentinel-1, -2 & -3 missions have different but very demanding requirements in terms of orbital accuracy and timeliness. Orbital products in Near Real Time (latency: 30 min), Short Time Critical (1.5 days) and Non-time Critical (20-30 days) are required. The accuracy requirements are very challenging, targeting 5 cm in 3D for Sentinel-1 and 2-3 cm in radial direction for Sentinel-3. Sentinel-3A carries, in addition to a GPS receiver a laser retro reflector and a DORIS receiver. On the one hand, the three different techniques GPS, SLR and DORIS make POD more complex but, on the other hand, it is very helpful to have independent techniques available for validation of the orbit results. The successful POD processing for Sentinel-1A is a good preparation for Sentinel-3A due to the similar demanding orbit accuracy requirements. The Copernicus POD Service is ready for Sentinel-3A and the service will process GPS and SLR data routinely and has the capacity to process DORIS in NTC and reprocessing campaigns. The three independent orbit determination techniques on Sentinel-3 offer big potential for scientific exploitation. Carrying all three techniques together makes the satellite, e.g., very useful for combining all the techniques on observation level as it could only be done for Jason-2 until now. The Sentinel POD Quality Working Group strongly supporting the CPOD Service delivers additional orbit solutions to validate the CPOD results independently. The recommendations from this body guarantee that the CPOD Service is updated following state-of-the-art algorithms, models and conventions. The QWG also focuses on the scientific exploitation of the

  3. Implementing Sentinels in the TARGIT BI Suite

    DEFF Research Database (Denmark)

    Middelfart, Morten; Pedersen, Torben Bach

    2011-01-01

    This paper describes the implementation of socalled sentinels in the TARGIT BI Suite. Sentinels are a novel type of rules that can warn a user if one or more measure changes in a multi-dimensional data cube are expected to cause a change to another measure critical to the user. Sentinels notify u...... pattern mining or correlation techniques. We demonstrate, through extensive experiments, that mining and usage of sentinels is feasible with good performance for the typical users on a real, operational data warehouse....

  4. Sentinel lymph node biopsy in oral cancer

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Grupe, Peter

    2005-01-01

    PURPOSE: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. MATERIAL......: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis (P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel...

  5. Preliminary geologic map of the Sleeping Butte volcanic centers

    International Nuclear Information System (INIS)

    Crowe, B.M.; Perry, F.V.

    1991-07-01

    The Sleeping Butte volcanic centers comprise two, spatially separate, small-volume ( 3 ) basaltic centers. The centers were formed by mildly explosive Strombolian eruptions. The Little Black Peak cone consists of a main scoria cone, two small satellitic scoria mounds, and associated lobate lava flows that vented from sites at the base of the scoria cone. The Hidden Cone center consists of a main scoria cone that developed on the north-facing slope of Sleeping Butte. The center formed during two episodes. The first included the formation of the main scoria cone, and venting of aa lava flows from radial dikes at the northeast base of the cone. The second included eruption of scoria-fall deposits from the summit crater. The ages of the Little Black Peak and the Hidden Cone are estimated to be between 200 to 400 ka based on the whole-rock K-Ar age determinations with large analytical undertainty. This age assignment is consistent with qualitative observations of the degree of soil development and geomorphic degradation of volcanic landforms. The younger episode of the Hidden Cone is inferred to be significantly younger and probably of Late Pleistocene or Holocene age. This is based on the absence of cone slope rilling, the absence of cone-slope apron deposits, and erosional unconformity between the two episodes, the poor horizon- development of soils, and the presence of fall deposits on modern alluvial surfaces. Paleomagnetic data show that the centers record similar but not identical directions of remanent magnetization. Paleomagnetic data have not been obtained for the youngest deposits of the Hidden Cone center. Further geochronology, soils, geomorphic, and petrology studies are planned of the Sleeping Butte volcanic centers 20 refs., 3 figs

  6. Littered cigarette butts as a source of nicotine in urban waters

    Science.gov (United States)

    Roder Green, Amy L.; Putschew, Anke; Nehls, Thomas

    2014-11-01

    The effect of nicotine from littered cigarette butts on the quality of urban water resources has yet to be investigated. This two-part study addresses the spatial variation, seasonal dynamics and average residence time of littered cigarette butts in public space, as well as the release of nicotine from cigarette butts to run-off in urban areas during its residence time. Thereby, we tested two typical situations: release to standing water in a puddle and release during alternating rainfall and drying. The study took place in Berlin, Germany, a city which completely relies on its own water resources to meet its drinking water demand. Nine typical sites located in a central district, each divided into 20 plots were studied during five sampling periods between May 2012 and February 2013. The nicotine release from standardized cigarette butts prepared with a smoking machine was examined in batch and rainfall experiments. Littered cigarette butts are unevenly distributed among both sites and plots. The average butt concentration was 2.7 m-2 (SD = 0.6 m-2, N = 862); the maximum plot concentration was 48.8 butts m-2. This heterogeneity is caused by preferential littering (gastronomy, entrances, bus stops), redistribution processes such as litter removal (gastronomy, shop owners), and the increased accumulation in plots protected from mechanized street sweeping (tree pits, bicycle stands). No significant seasonal variation of cigarette butt accumulation was observed. On average, cigarette butt accumulation is characterized by a 6 days cadence due to the rhythm and effectiveness of street sweeping (mean weekly butt accumulation rate = 0.18 m-2 d-1; SD = 0.15 m-1). Once the butt is exposed to standing water, elution of nicotine occurs rapidly. Standardized butts released 7.3 mg g-1 nicotine in a batch experiment (equivalent to 2.5 mg L-1), 50% of which occurred within the first 27 min. In the rainfall experiment, the cumulative nicotine release from fifteen consecutive

  7. Sentinel node concept in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kiricuta, I.C. [St. Vincenz-Hospital, Limburg (Germany). Inst. for Radiation Oncology

    2000-07-01

    Background/purpose: It seems that there exists a specific lymph node center called sentinel node (SN) which appears to be the primary site of metastases. The sentinel node concept (SNC) is fundamentally based on the orderly progression of tumor cells within the lymphatic system. It is the most important new concept in surgical and radiation oncology. The purpose is to present the biological significance, the diagnostic and clinical basis of the sentinel node concept in breast cancer patients. Material and methods: Lymphoscintigraphy and gamma probe biopsy is necessary to show predictable lymph flow to the regional sentinel node, to multiple sentinel nodes or unpredictable lymph flow to extra-regional sentinel nodes and for performing sentinel node procedure. The standard protocol for the evaluation of the sentinel node metastases consists of extensive histopathological investigation including step Hematoxylin and Eosin (H and E) stained sections and immunohistochemistry. Results: A high rate of success of the identification of the sentinel node for breast cancer was reported. The presence or absence of metastasis in this node is a very accurate predictor of overall nodal status. The temptation to examine the sentinel node with the greatest possible degree of accuracy highlights one of the major problems related to sentinel node biopsy. The success of the sentinel node procedure depends primarily on the adequate functional capacity necessary for sufficient uptake to ensure the accurate identification. In negative sentinel-node patients a complete axillary lymph node dissection is avoidable. In sentinel-node positive patients and clinically negative patients a postoperative radiotherapy would permit an adequate tumor control. The last 2-procedures permit a low morbidity. In the actual TNM classification it was recently introduced a definition of a 'pN0' patient based on sentinel node biopsy. New target volumes are defined for adjuvant radiotherapy or

  8. A Neural Network Approach for GMA Butt Joint Welding

    DEFF Research Database (Denmark)

    Christensen, Kim Hardam; Sørensen, Torben

    2003-01-01

    This paper describes the application of the neural network technology for gas metal arc welding (GMAW) control. A system has been developed for modeling and online adjustment of welding parameters, appropriate to guarantee a certain degree of quality in the field of butt joint welding with full...... penetration, when the gap width is varying during the welding process. The process modeling to facilitate the mapping from joint geometry and reference weld quality to significant welding parameters has been based on a multi-layer feed-forward network. The Levenberg-Marquardt algorithm for non-linear least...

  9. A Neural Network Approach for GMA Butt Joint Welding

    DEFF Research Database (Denmark)

    Christensen, Kim Hardam; Sørensen, Torben

    2003-01-01

    penetration, when the gap width is varying during the welding process. The process modeling to facilitate the mapping from joint geometry and reference weld quality to significant welding parameters has been based on a multi-layer feed-forward network. The Levenberg-Marquardt algorithm for non-linear least......This paper describes the application of the neural network technology for gas metal arc welding (GMAW) control. A system has been developed for modeling and online adjustment of welding parameters, appropriate to guarantee a certain degree of quality in the field of butt joint welding with full...

  10. Observations of elk movement patterns on Fossil Butte National Monument

    Science.gov (United States)

    Olexa, Edward M.; Soileau, Suzanna Carrithers.; Allen, Leslie A.

    2014-01-01

    The elk herd that frequents Fossil Butte National Monument, a subset of the West Green River elk population, provides visitors with seasonal opportunities to view an iconic species of the western United States. Throughout the year, these elk range across a variety of private, State, and Federal lands within close proximity to the Monument. These lands are managed differently for various uses which can create challenging wildlife-management issues and influence the herd’s seasonal movements and distribution. Research lead by the USGS investigates some of the factors associated with these seasonal changes.

  11. Radio and television use in Butte County, California: application to fire prevention

    Science.gov (United States)

    William S. Folkman

    1975-01-01

    A sample of Butte County residents were interviewed about their radio and television use habits. Their responses were analyzed in terms of demographic, social, and economic characteristics. The findings can be used in developing more effective fire prevention programs. Most people in Butte County listen to the radio or watch television but they differ widely in the way...

  12. 77 FR 39735 - Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines

    Science.gov (United States)

    2012-07-05

    ... revocation of the antidumping duty orders on stainless steel butt-weld pipe fittings From Italy, Malaysia... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 731-TA-865-867 (Second Review)] Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines Determination On the basis of the...

  13. 75 FR 76025 - Stainless Steel Butt-Weld Pipe Fittings From Japan, Korea, and Taiwan

    Science.gov (United States)

    2010-12-07

    ... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 731-TA-376 and 563-564 (Third Review)] Stainless Steel Butt-Weld Pipe Fittings From Japan, Korea, and Taiwan AGENCY: United States International... steel butt-weld pipe fittings from Japan, Korea, and Taiwan would be likely to lead to continuation or...

  14. The hidden sentinel node in breast cancer

    NARCIS (Netherlands)

    Tanis, P. J.; van Sandick, J. W.; Nieweg, O. E.; Valdés Olmos, R. A.; Rutgers, E. J. T.; Hoefnagel, C. A.; Kroon, B. B. R.

    2002-01-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures)

  15. Discovering Sentinel Rules for Business Intelligence

    DEFF Research Database (Denmark)

    Middelfart, Morten; Pedersen, Torben Bach

    2009-01-01

    This paper proposes the concept of sentinel rules for multi-dimensional data that warns users when measure data concerning the external environment changes. For instance, a surge in negative blogging about a company could trigger a sentinel rule warning that revenue will decrease within two month...

  16. A Methodology for the Assessment of Unconventional (Continuous) Resources with an Application to the Greater Natural Buttes Gas Field, Utah

    International Nuclear Information System (INIS)

    Olea, Ricardo A.; Cook, Troy A.; Coleman, James L.

    2010-01-01

    The Greater Natural Buttes tight natural gas field is an unconventional (continuous) accumulation in the Uinta Basin, Utah, that began production in the early 1950s from the Upper Cretaceous Mesaverde Group. Three years later, production was extended to the Eocene Wasatch Formation. With the exclusion of 1100 non-productive ('dry') wells, we estimate that the final recovery from the 2500 producing wells existing in 2007 will be about 1.7 trillion standard cubic feet (TSCF) (48.2 billion cubic meters (BCM)). The use of estimated ultimate recovery (EUR) per well is common in assessments of unconventional resources, and it is one of the main sources of information to forecast undiscovered resources. Each calculated recovery value has an associated drainage area that generally varies from well to well and that can be mathematically subdivided into elemental subareas of constant size and shape called cells. Recovery per 5-acre cells at Greater Natural Buttes shows spatial correlation; hence, statistical approaches that ignore this correlation when inferring EUR values for untested cells do not take full advantage of all the information contained in the data. More critically, resulting models do not match the style of spatial EUR fluctuations observed in nature. This study takes a new approach by applying spatial statistics to model geographical variation of cell EUR taking into account spatial correlation and the influence of fractures. We applied sequential indicator simulation to model non-productive cells, while spatial mapping of cell EUR was obtained by applying sequential Gaussian simulation to provide multiple versions of reality (realizations) having equal chances of being the correct model. For each realization, summation of EUR in cells not drained by the existing wells allowed preparation of a stochastic prediction of undiscovered resources, which range between 2.6 and 3.4 TSCF (73.6 and 96.3 BCM) with a mean of 2.9 TSCF (82.1 BCM) for Greater Natural Buttes

  17. Discovering Sentinel Rules for Business Intelligence

    Science.gov (United States)

    Middelfart, Morten; Pedersen, Torben Bach

    This paper proposes the concept of sentinel rules for multi-dimensional data that warns users when measure data concerning the external environment changes. For instance, a surge in negative blogging about a company could trigger a sentinel rule warning that revenue will decrease within two months, so a new course of action can be taken. Hereby, we expand the window of opportunity for organizations and facilitate successful navigation even though the world behaves chaotically. Since sentinel rules are at the schema level as opposed to the data level, and operate on data changes as opposed to absolute data values, we are able to discover strong and useful sentinel rules that would otherwise be hidden when using sequential pattern mining or correlation techniques. We present a method for sentinel rule discovery and an implementation of this method that scales linearly on large data volumes.

  18. The hidden sentinel node in breast cancer

    International Nuclear Information System (INIS)

    Tanis, P.J.; Sandick, J.W. van; Nieweg, O.E.; Rutgers, E.J.T.; Kroon, B.B.R.; Valdes Olmos, R.A.; Hoefnagel, C.A.

    2002-01-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures) after injection of technetium-99m nanocolloid. Anterior and prone lateral (hanging breast) planar images were obtained a few minutes and 4 h after injection. The sentinel node was intraoperatively identified with the aid of patent blue dye and a gamma-ray detection probe. A sentinel node was visualised on the 4-h images in 449 of 501 procedures (90%). This visualisation rate improved from 76% to 94% during the study period. Delayed imaging (5-23 h) in 19 patients whose sentinel nodes failed to show, resulted in visualisation in four of them. A repeat injection of radiocolloid in 11 patients revealed a sentinel node in six. In the end, the visualisation rate was 92%. The sentinel node was surgically retrieved in 24 of the remaining 42 patients with non-visualisation (57%). Sentinel nodes that were visualised were tumour-positive in 38% and non-visualised sentinel nodes were involved in 50% (χ 2 , P=0.17). In a multivariate regression analysis, scintigraphic non-visualisation was independently associated with increased patient age (P<0.001), decreased tracer dose (P<0.001) and increased number of tumour-positive lymph nodes (P=0.013). The use of a sufficient amount of radioactivity (at least 100 MBq) is recommended for lymphatic mapping in breast cancer, especially in elderly women. Delayed imaging and re-injection of the radioactive tracer increase the visualisation rate. The non-visualised sentinel node can be identified intraoperatively in more than half of the patients. (orig.)

  19. The hidden sentinel node in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, P.J.; Sandick, J.W. van; Nieweg, O.E.; Rutgers, E.J.T.; Kroon, B.B.R. [Department of Surgery, Netherlands Cancer Institute, Amsterdam (Netherlands); Valdes Olmos, R.A.; Hoefnagel, C.A. [Department of Nuclear Medicine, Netherlands Cancer Institute, Amsterdam (Netherlands)

    2002-03-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures) after injection of technetium-99m nanocolloid. Anterior and prone lateral (hanging breast) planar images were obtained a few minutes and 4 h after injection. The sentinel node was intraoperatively identified with the aid of patent blue dye and a gamma-ray detection probe. A sentinel node was visualised on the 4-h images in 449 of 501 procedures (90%). This visualisation rate improved from 76% to 94% during the study period. Delayed imaging (5-23 h) in 19 patients whose sentinel nodes failed to show, resulted in visualisation in four of them. A repeat injection of radiocolloid in 11 patients revealed a sentinel node in six. In the end, the visualisation rate was 92%. The sentinel node was surgically retrieved in 24 of the remaining 42 patients with non-visualisation (57%). Sentinel nodes that were visualised were tumour-positive in 38% and non-visualised sentinel nodes were involved in 50% ({chi}{sup 2}, P=0.17). In a multivariate regression analysis, scintigraphic non-visualisation was independently associated with increased patient age (P<0.001), decreased tracer dose (P<0.001) and increased number of tumour-positive lymph nodes (P=0.013). The use of a sufficient amount of radioactivity (at least 100 MBq) is recommended for lymphatic mapping in breast cancer, especially in elderly women. Delayed imaging and re-injection of the radioactive tracer increase the visualisation rate. The non-visualised sentinel node can be identified intraoperatively in more than half of the patients. (orig.)

  20. 77 FR 14002 - Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines: Final Results...

    Science.gov (United States)

    2012-03-08

    ...] Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines: Final Results of the... Duty Orders on Stainless Steel Butt-Weld Pipe Fittings from Italy, Malaysia, and the Philippines'' from... Commerce (the Department) initiated sunset reviews of the antidumping duty orders on stainless steel butt...

  1. 77 FR 42697 - Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines: Continuation...

    Science.gov (United States)

    2012-07-20

    ...] Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines: Continuation of... from Italy, Malaysia, and the Philippines.\\2\\ \\1\\ See Antidumping Duty Orders: Stainless Steel Butt...), titled Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines (Investigation...

  2. 76 FR 67473 - Stainless Steel Butt-Weld Pipe Fittings from Italy, Malaysia, and The Philippines; Institution of...

    Science.gov (United States)

    2011-11-01

    ... Concerning the Antidumping Duty Orders on Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and... stainless steel butt-weld pipe fittings from Italy, Malaysia, and the Philippines would be likely to lead to... antidumping duty orders on imports of stainless steel butt-weld pipe fittings from Italy, Malaysia, and the...

  3. Mountain Plant Community Sentinels: AWOL

    Science.gov (United States)

    Malanson, G. P.

    2017-12-01

    Mountain plant communities are thought to be sensitive to climate change. Because climatic gradients are steep on mountain slopes, the spatial response of plant communities to climate change should be compressed and easier to detect. These expectations have led to identifying mountain plant communities as sentinels for climate change. This idea has, however, been criticized. Two critiques, for alpine treeline and alpine tundra, are rehearsed and supplemented. The critique of alpine treeline as sentinel is bolstered with new model results on the confounding role of dispersal mechanisms and sensitivity to climatic volatility. In alpine tundra, for which background turnover rates have yet to be established, community composition may reflect environmental gradients only for extremes where effects of climate are most indirect. Both plant communities, while primarily determined by energy at broad scales, may respond to water as a proximate driver at local scales. These plant communities may not be in equilibrium with climate, and differently scaled time lags may mean that ongoing vegetation change may not signal ongoing climate change (or lack thereof). In both cases a double-whammy is created by scale dependence for time lags and for drivers leading to confusion, but these cases present opportunities for insights into basic ecology.

  4. Sentinel Node in Oral Cancer

    DEFF Research Database (Denmark)

    Tartaglione, Girolamo; Stoeckli, Sandro J; de Bree, Remco

    2016-01-01

    /static scan and/or SPECT/CT. RESULTS: Lymphoscintigraphy identified 723 lymphatic basins. 1398 sentinel lymph nodes (SNs) were biopsied (3.2 SN per patient; range, 1-10). Dynamic scan allowed the differentiation of sentinel nodes from second tier lymph nodes. SPECT/CT allowed more accurate anatomical......PURPOSE: Nuclear imaging plays a crucial role in lymphatic mapping of oral cancer. This evaluation represents a subanalysis of the original multicenter SENT trial data set, involving 434 patients with T1-T2, N0, and M0 oral squamous cell carcinoma. The impact of acquisition techniques, tracer...... localization and estimated SN depth more efficiently. After pathological examination, 9.9% of the SN excised (138 of 1398 SNs) showed metastases. The first neck level (NL) containing SN+ was NL I in 28.6%, NL IIa in 44.8%, NL IIb in 2.8%, NL III in 17.1%, and NL IV in 6.7% of positive patients. Approximately...

  5. Concordance between peri-areolar blue dye and peri-incisional radiotracer injections for sentinel node mapping in patients with a history of primary breast cancer excisonal biopsy.

    Science.gov (United States)

    Mehrabibahar, M; Azizi, S; Jangjoo, A; Saremi, E; Kakhki, V R Dabbagh; Sadeghi, R; Chicken, D W; Keshtgar, M

    2014-01-01

    We evaluated the concordance between peri-areolar blue dye and peri-incisional radiotracer injections for axillary sentinel node mapping of patients with the history of previous breast lesion excisional biopsy. 80 patients with the history of previous excisional biopsy of the breast lesions were included. All patients received two injections of 99mTc-antimony sulfide colloid in both ends of incision line in an intradermal fashion. 2 mL patient blue V dye was injection to all patients in the peri-areolar area of the index quadrant after induction of anesthesia. All blue or hot nodes were harvested as sentinel lymph nodes. At least one sentinel node could be detected during surgery in 79 patients. In total 94 sentinel nodes were detected. All detected sentinel nodes were hot. In three patients sentinel nodes were detected by gamma probe but not blue dye. The tumor location in all of these patients was in the upper lateral quadrant and the incision line was extended into the axillary tail of the breast in all of them. 91 out of 94 sentinel nodes were stained blue, which amounts to 95.8% concordance between blue dye and radiotracer on a per node analysis. Single peri-areolar injection in the index quadrant would suffice for sentinel node mapping of patients with history of excisional biopsy. Care should be taken in patients with large excisional biopsy in the extreme proximity to axilla.

  6. Contrast enhanced ultrasound of sentinel lymph nodes

    Directory of Open Access Journals (Sweden)

    XinWu Cui

    2013-03-01

    Full Text Available Sentinel lymph nodes are the first lymph nodes in the region that receive lymphatic drainage from a primary tumor. The detection or exclusion of sentinel lymph node micrometastases is critical in the staging of cancer, especially breast cancer and melanoma because it directly affects patient’s prognosis and surgical management. Currently, intraoperative sentinel lymph node biopsies using blue dye and radioisotopes are the method of choice for the detection of sentinel lymph node with high identification rate. In contrast, conventional ultrasound is not capable of detecting sentinel lymph nodes in most cases. Contrast enhanced ultrasound with contrast specific imaging modes has been used for the evaluation and diagnostic work-up of peripherally located suspected lymphadenopathy. The method allows for real-time analysis of all vascular phases and the visualization of intranodal focal “avascular” areas that represent necrosis or deposits of neoplastic cells. In recent years, a number of animal and human studies showed that contrast enhanced ultrasound can be also used for the detection of sentinel lymph node, and may become a potential application in clinical routine. Several contrast agents have been used in those studies, including albumin solution, hydroxyethylated starch, SonoVue®, Sonazoid® and Definity®. This review summarizes the current knowledge about the use of ultrasound techniques in detection and evaluation of sentinel lymph node.

  7. The Western Environmental Technology Office (WETO), Butte, Montana, technology summary

    International Nuclear Information System (INIS)

    1994-09-01

    This document has been prepared by the DOE Environmental Management (EM) Office of Technology Development (OTD) to highlight its research, development, demonstration, testing, and evaluation activities funded through the Western Environmental Technology Office (WETO) in Butte, Montana. Technologies and processes described have the potential to enhance DOE's cleanup and waste management efforts, as well as improve US industry's competitiveness in global environmental markets. WETO's environmental technology research and testing activities focus on the recovery of useable resources from waste. Environmental technology development and commercialization activities will focus on mine cleanup, waste treatment, resource recovery, and water resource management. Since the site has no record of radioactive material use and no history of environmental contamination/remediation activities, DOE-EM can concentrate on performing developmental and demonstration activities without the demands of regulatory requirements and schedules. Thus, WETO will serve as a national resource for the development of new and innovative environmental technologies

  8. The Western Environmental Technology Office (WETO), Butte, Montana, technology summary

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    This document has been prepared by the DOE Environmental Management (EM) Office of Technology Development (OTD) to highlight its research, development, demonstration, testing, and evaluation activities funded through the Western Environmental Technology Office (WETO) in Butte, Montana. Technologies and processes described have the potential to enhance DOE`s cleanup and waste management efforts, as well as improve US industry`s competitiveness in global environmental markets. WETO`s environmental technology research and testing activities focus on the recovery of useable resources from waste. Environmental technology development and commercialization activities will focus on mine cleanup, waste treatment, resource recovery, and water resource management. Since the site has no record of radioactive material use and no history of environmental contamination/remediation activities, DOE-EM can concentrate on performing developmental and demonstration activities without the demands of regulatory requirements and schedules. Thus, WETO will serve as a national resource for the development of new and innovative environmental technologies.

  9. The Western Environmental Technology Office (WETO) Butte, Montana

    International Nuclear Information System (INIS)

    1994-10-01

    This document has been prepared to highlight the research, development, demonstration, testing and evaluation activities funded through the Western Environmental Technology Office (WETO) in Butte, Montana. Technologies and processes described have the potential to enhance DOE's cleanup and waste management efforts, as well as improve US industry's competitiveness in global environmental markets. This information has been assembled from recently produced Office of Technology Development (OTD) documents which highlight technology development activities within each of the OTD program elements. Projects include: Heavy metals contaminated soil project; In Situ remediation integrated program; Minimum additive waste stabilization program; Resource recovery project; Buried waste integrated demonstration; Mixed waste integrated program; Pollution prevention program; and Mine waste technology program

  10. Features of residual stresses in duplex stainless steel butt welds

    Science.gov (United States)

    Um, Tae-Hwan; Lee, Chin-Hyung; Chang, Kyong-Ho; Nguyen Van Do, Vuong

    2018-04-01

    Duplex stainless steel finds increasing use as an alternative to austenitic stainless steel, particularly where chloride or sulphide stress corrosion cracking is of primary concern, due to the excellent combination of strength and corrosion resistance. During welding, duplex stainless steel does not create the same magnitude or distribution of weld-induced residual stresses as those in welded austenitic stainless steel due to the different physical and mechanical properties between them. In this work, an experimental study on the residual stresses in butt-welded duplex stainless steel is performed utilizing the layering technique to investigate the characteristics of residual stresses in the weldment. Three-dimensional thermos-mechanical-metallurgical finite element analysis is also performed to confirm the residual stress measurements.

  11. BUSTED BUTTE TEST FACILITY GROUND SUPPORT CONFIRMATION ANALYSIS

    International Nuclear Information System (INIS)

    Bonabian, S.

    1998-01-01

    The main purpose and objective of this analysis is to confirm the validity of the ground support design for Busted Butte Test Facility (BBTF). The highwall stability and adequacy of highwall and tunnel ground support is addressed in this analysis. The design of the BBTF including the ground support system was performed in a separate document (Reference 5.3). Both in situ and seismic loads are considered in the evaluation of the highwall and the tunnel ground support system. In this analysis only the ground support designed in Reference 5.3 is addressed. The additional ground support installed (still work in progress) by the constructor is not addressed in this analysis. This additional ground support was evaluated by the A/E during a site visit and its findings and recommendations are addressed in this analysis

  12. Use of pulsed arc welding for butt joint fabrication

    International Nuclear Information System (INIS)

    Merkulov, B.A.

    1977-01-01

    A technology of pulsed-arc butt welding with periodic wire feed to the welding zone has been developed. The pulsed arc is suitable both for submerged and gas-shielded weldings. The technology proposed has some advantages over the stationary-arc welding. Control of the amplitude-frequency characteristics of the process enables one to affect melting and crystallization conditions of the welding crater, weld shape, relation between melting and deposited metal section areas, etc., as well as to reduce heat contribution to the base metal. The new process is shown to be applicable in power engineering. Automatic submerged welding conditions are given for low-carbon and pearlitic heat-resistant steels

  13. Numerical estimation of temperature field in a laser welded butt joint made of dissimilar materials

    Directory of Open Access Journals (Sweden)

    Saternus Zbigniew

    2018-01-01

    Full Text Available The paper concerns numerical analysis of thermal phenomena occurring in the butt welding of two different materials by a laser beam welding. The temperature distribution for the welded butt-joint is obtained on the basis of numerical simulations performed in the ABAQUS program. Numerical analysis takes into account the thermophysical properties of welded plate made of two different materials. Temperature distribution in analysed joints is obtained on the basis of numerical simulation in Abaqus/Standard solver, which allowed the determination of the geometry of laser welded butt-joint.

  14. Sentinel node biopsy in penile cancer

    DEFF Research Database (Denmark)

    Jakobsen, J. K.; Krarup, K. P.; Sommer, P.

    2015-01-01

    INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow-up. In th......INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow...... died from complications. CONCLUSIONS: To our knowledge, this is the first complete national study on sentinel node biopsy. Penile cancer sentinel node biopsy with a close follow-up is a reliable lymph node staging and has few complications in a national multicentre setting. Inguinal lymph node...

  15. Sentinel lymph node imaging in breast cancer

    International Nuclear Information System (INIS)

    Kim, Byung Tae

    1999-01-01

    Currently, dissection of the axillary or regional lymph nodes is considered the standard staging procedure in breast cancer. However, accumulating evidence is becoming available that the sentinel node concept may provide the same or even better staging information. In the case of melanoma, it is proven that the histological characteristics of the sentinel node reflect the histological characteristics of the distal part of the lymphatic basin. Morbidity can be reduced significantly by the use of sentinel node dissection as several authors have reported successful introduction of this technique into clinical practice. But in breast cancer patients, there are significant differences in practice relating to the technology, such as radiopharmaceuticals, injection sites, volume of injectate, combination with vital blue dye, preoperative lymphoscintigraphy, etc. Valuable reports on these topics appeared in recent journals. This review is a summary of those reports for nuclear physicians interested in sentinel node detection by lymphoscintigraphy in breast cancer patients

  16. SENTINEL-1 RESULTS: SEA ICE OPERATIONAL MONITORING

    DEFF Research Database (Denmark)

    Toudal Pedersen, Leif; Saldo, Roberto; Fenger-Nielsen, Rasmus

    2015-01-01

    In the present paper we demonstrate the capabilities of the Sentinel-1 SAR data for operational sea-ice and iceberg monitoring. Most of the examples are drawn from the Copernicus Marine Environmental Monitoring Service (CMEMS) production.......In the present paper we demonstrate the capabilities of the Sentinel-1 SAR data for operational sea-ice and iceberg monitoring. Most of the examples are drawn from the Copernicus Marine Environmental Monitoring Service (CMEMS) production....

  17. The Sentinel 4 focal plane subsystem

    Science.gov (United States)

    Hohn, Rüdiger; Skegg, Michael P.; Hermsen, Markus; Hinger, Jürgen; Williges, Christian; Reulke, Ralf

    2017-09-01

    The Sentinel 4 instrument is an imaging spectrometer, developed by Airbus under ESA contract in the frame of the joint European Union (EU)/ESA COPERNICUS program with the objective of monitoring trace gas concentrations. Sentinel 4 will provide accurate measurements of key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, formaldehyde, as well as aerosol and cloud properties. Sentinel 4 is unique in being the first geostationary UVN mission. The SENTINEL 4 space segment will be integrated on EUMETSAT's Meteosat Third Generation Sounder satellite (MTG-S). Sentinel 4 will provide coverage of Europe and adjacent regions. The Sentinel 4 instrument comprises as a major element two Focal Plane Subsystems (FPS) covering the wavelength ranges 305 nm to 500 nm (UVVIS) and 750 nm to 775 nm (NIR) respectively. The paper describes the Focal Plane Subsystems, comprising the detectors, the optical bench and the control electronics. Further the design and development approach will be presented as well as first measurement results of FPS Qualification Model.

  18. The SENTINEL-3 Mission: Overview and Status

    Science.gov (United States)

    Benveniste, J.; Mecklenburg, S.

    2015-12-01

    The Copernicus Programme, being Europe's Earth Observation and Monitoring Programme led by the European Union, aims to provide, on a sustainable basis, reliable and timely services related to environmental and security issues. The Sentinel-3 mission forms part of the Copernicus Space Component. Its main objectives, building on the heritage and experience of the European Space Agency's (ESA) ERS and ENVISAT missions, are to measure sea-surface topography, sea- and land-surface temperature and ocean- and land-surface colour in support of ocean forecasting systems, and for environmental and climate monitoring. The series of Sentinel-3 satellites will ensure global, frequent and near-real time ocean, ice and land monitoring, with the provision of observation data in routine, long term (up to 20 years of operations) and continuous fashion, with a consistent quality and a high level of reliability and availability. The Sentinel-3 missions will be jointly operated by ESA and EUMETSAT. ESA will be responsible for the operations, maintenance and evolution of the Sentinel-3 ground segment on land related products and EUMETSAT for the marine products. The Sentinel-3 ground segment systematically acquires, processes and distributes a set of pre-defined core data products. Sentinel-3A is foreseen to be launched at the beginning of November 2015. The paper will give an overview on the mission, its instruments and objectives, the data products provided, the mechanisms to access the mission's data, and if available first results.

  19. 78 FR 21540 - Revisions to the California State Implementation Plan, Butte County Air Quality Management...

    Science.gov (United States)

    2013-04-11

    ... the California State Implementation Plan, Butte County Air Quality Management District and Sacramento Metropolitan Air Quality Management District AGENCY: Environmental Protection Agency (EPA). ACTION: Direct... Quality Management District (BCAQMD) and Sacramento Metropolitan Air Quality Management District (SMAQMD...

  20. California State Implementation Plan; Butte County Air Quality Management District; New Source Review (NSR) Permitting Program

    Science.gov (United States)

    EPA is proposing to approve a revision to the Butte County Air Quality Management District (BCAQMD) portion of the California SIP concerning the District's New Source Review (NSR) permitting program for new and modified sources of air pollution.

  1. Computational Modeling of Microstructural-Evolution in AISI 1005 Steel During Gas Metal Arc Butt Welding

    Science.gov (United States)

    2013-05-01

    H.K.D.H. Bhadeshia, A Model for the Microstruc- ture of Some Advanced Bainitic Steels , Mater. Trans., 1991, 32, p 689–696 19. G.J. Davies and J.G. Garland...REPORT Computational Modeling of Microstructural-Evolution in AISI 1005 Steel During Gas Metal Arc Butt Welding 14. ABSTRACT 16. SECURITY...Computational Modeling of Microstructural-Evolution in AISI 1005 Steel During Gas Metal Arc Butt Welding Report Title ABSTRACT A fully coupled (two-way

  2. Critical Gap distance in Laser Butt-welding

    DEFF Research Database (Denmark)

    Bagger, Claus; Olsen, Flemming Ove

    1999-01-01

    In a number of systematic laboratory experiments the critical gap distance that results in sound beads in laser butt welding is sought identified. By grinding the edges of the sheets, a number of "reference" welds are made and compared to the sheets with shear cut edges. In the tests the gap...... was set at 0.00, 0.02, 0.05, 0.08 and 0.10 mm. Mild steel (St 1203) with a thickness of 0.75 and 1.25 mm with and without zinc coating were analysed. A total of 120 welds were made at different welding speeds.As quality norm DIN 8563 was used to divide the welds into quality classes. A number of welds...... were also x-ray photographed.Of the weld combinations analysed 80 % were of high quality and 17 % of a non-acceptable quality. 90 % of the bad welds had a gap distance larger than 0.05 mm. The results showed that 85 % of the bad welds were shear cut and only 15 % grinded. Two third of the bad welds...

  3. Critical Gap distance in Laser Butt-welding

    DEFF Research Database (Denmark)

    Bagger, Claus; Olsen, Flemming Ove

    of "reference" welds are made and compared to sheets with the edges shear cut. The gap distance is precisely controlled by inserting spacers between the sheets. In the tests the gap is set at 0.00, 0.02, 0.05, 0.08 and 0.10 mm. Mild steel (St 1203) with thickness? of 0.75 and 1.25 mm with and without zinc......When butt-welding metal sheets with high power lasers the gap distance between the sheets determine the final quality of the seam. In a number of systematic laboratory experiments the critical gap distance that results in sound beads is identified. By grinding the edges of the sheets, a number...... coating were analysed. A total of 120 welds are made at different welding speeds.As quality norm DIN 8563 is used to divide the welds into quality classes. Since this norm only deals with surface defects a number of welds are also x-ray photographed.According to DIN 8563 the welds have classes of either B...

  4. Residual-stress distributions near stainless steel butt weldments

    International Nuclear Information System (INIS)

    Elligson, W.A.; Shack, W.J.

    1978-01-01

    Concern for the integrity of stainless steel butt-weldments in boiling-water-reactor (BWR) piping systems has stimulated study of the conditions that cause stress corrosion cracking (SCC) in the heat-affected zones (HAZ) of the weldments. It is generally agreed that a high stress exceeding the initial yield strength is one of the essential elements for crack initiation. Since design procedures usually ensure that load stresses are below initial yield, the source of the high stresses necessary to produce SCC is thought to be the residual stresses due to welding. To examine the level of residual stresses in the weldments of interest, bulk residual stresses were measured on 100 mm (4-in.) and 254 mm (10-in.) diameter Schedule 80 piping weldments using strain relief techniques. Both laboratory welded specimens and field welded specimens from reactors in service were studied. Axial bulk residual stress distributions were obtained at 45 0 intervals around the circumference. At each azimuthal position, the residual stresses were measured at seven axial positions: on the weld centerline and 13, 20, and 25 mm on either side of the weld centerline on both the inside and outside surfaces

  5. Tobacco industry responsibility for butts: a Model Tobacco Waste Act.

    Science.gov (United States)

    Curtis, Clifton; Novotny, Thomas E; Lee, Kelley; Freiberg, Mike; McLaughlin, Ian

    2017-01-01

    Cigarette butts and other postconsumer products from tobacco use are the most common waste elements picked up worldwide each year during environmental cleanups. Under the environmental principle of Extended Producer Responsibility, tobacco product manufacturers may be held responsible for collection, transport, processing and safe disposal of tobacco product waste (TPW). Legislation has been applied to other toxic and hazardous postconsumer waste products such as paints, pesticide containers and unused pharmaceuticals, to reduce, prevent and mitigate their environmental impacts. Additional product stewardship (PS) requirements may be necessary for other stakeholders and beneficiaries of tobacco product sales and use, especially suppliers, retailers and consumers, in order to ensure effective TPW reduction. This report describes how a Model Tobacco Waste Act may be adopted by national and subnational jurisdictions to address the environmental impacts of TPW. Such a law will also reduce tobacco use and its health consequences by raising attention to the environmental hazards of TPW, increasing the price of tobacco products, and reducing the number of tobacco product retailers. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Sentinel lymph node biopsy: An audit of intraoperative assessment ...

    African Journals Online (AJOL)

    2015-07-02

    Jul 2, 2015 ... Sentinel lymph node biopsy: An audit of ... cytotechnology service ... To audit results from intraoperative assessment of sentinel lymph node ..... out, and turnaround time in gynecologic cytology quality assurance: Findings.

  7. Sentinel lymph node biopsy: clinical relevance

    International Nuclear Information System (INIS)

    Howman-Giles, R.

    2002-01-01

    Sentinel lymph node biopsy (SLNB) has become an important technique in the management of patients with intermediate level melanoma, clinical operable breast cancer and some other cancers. The technique relies on lymphatic mapping to define the lymph drainage from a primary tumour with the premise that the lymph nodes, which directly drain from that area, will reflect the tumour status of the remainder of the node field. Current techniques use lymphoscintigraphy where a radioactive labelled particle and / or blue dye are injected intradermally or intraparenchymally to map the lymph drainage, often in conjunction with a radioactive gamma probe at surgery. In patients with melanoma the SLNB has improved the staging and prognostic information by more accurate determination of whether regional lymph nodes have metastatic spread. This has a major impact on patient management as those patients with negative nodes do not require regional lymph node dissection and have a significantly better prognosis. In our experience of over 3000 patients the combined sentinel node biopsy technique localised accurately 98% of sentinel lymph nodes. Lymphoscintigraphy in patients with melanoma to locate the sentinel lymph nodes involves the intradermal injection of a radiocolloid around the melanoma site or the excision biopsy site. Injections of 5 -10 MBq in 0.05-0.1ml/inj are used and typically 4 injections are usually required. Following tracer injection dynamic imaging is performed to follow the lymphatic collecting vessels until they reach the draining sentinel nodes. An image should be acquired as the vessels reach the node field so that the sentinel nodes directly receiving the channels can be identified and distinguished from any second tier nodes which may sometimes be seen. Delayed scans are performed 2 hours later at which time all regions which can possible drain the primary melanoma site are examined with 5-10 minute static images. The surface location of all sentinel nodes is

  8. The Sentinel-4 detectors: architecture and performance

    Science.gov (United States)

    Skegg, Michael P.; Hermsen, Markus; Hohn, Rüdiger; Williges, Christian; Woffinden, Charles; Levillain, Yves; Reulke, Ralf

    2017-09-01

    The Sentinel-4 instrument is an imaging spectrometer, developed by Airbus under ESA contract in the frame of the joint European Union (EU)/ESA COPERNICUS program. SENTINEL-4 will provide accurate measurements of trace gases from geostationary orbit, including key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, formaldehyde, as well as aerosol and cloud properties. Key to achieving these atmospheric measurements are the two CCD detectors, covering the wavelengths in the ranges 305 nm to 500 nm (UVVIS) and 750 to 775 nm (NIR) respectively. The paper describes the architecture, and operation of these two CCD detectors, which have an unusually high full-well capacity and a very specific architecture and read-out sequence to match the requirements of the Sentinel- 4 instrument. The key performance aspects and their verification through measurement are presented, with a focus on an unusual, bi-modal dark signal generation rate observed during test.

  9. Detection of sentinel nodes with radiopharmaceuticals

    International Nuclear Information System (INIS)

    Yokoyama, Kunihiko; Michigishi, Takatoshi; Kinuya, Seigo; Konishi, Shota; Nakajima, Kenichi; Tonami, Norihisa

    2000-01-01

    Sentinel lymph nodes have been found to be an indicator of lymph node metastasis in breast cancer. In Japan, the theory and concept of sentinel lymph nodes in breast cancer have begun to be applied to carcinomas of the digestive system. Based on clinical experience in the detection of sentinel lymph nodes with radiopharmaceuticals, differences and similarities between the radiopharmaceuticals, methods, and techniques used to detect sentinel lymph nodes have been assessed in relation to breast cancer and carcinomas of the digestive system (including carcinomas of the esophagus and large intestine). The greatest difference between the methods used for breast and digestive cancers is the site of administration of the radiopharmaceutical. In breast cancer, the radiopharmaceutical is administered into a superficial organ (i.e., the mammary gland), whereas in carcinomas of the digestive system, it is administered into a deep organ (i.e., digestive tract). Another obvious difference is in lymph flow, i.e., the flow of the mammary glands is subcutaneous whereas lymph flow in the digestive tract is submucosal. Two radionuclide diagnostic methods are available to detect sentinel lymph nodes: sentinel lymphoscintigraphy with a gamma camera and a method that involves the use of a gamma probe intraoperatively. Radiopharmaceuticals used to detect sentinel lymph nodes must be smoothly transferred from the site of administration into the lymph, and uptake by the sentinel lymph node must continue for a long time without excessive flowing to lower reaches. The optimal particle size remains a matter of controversy, and no radiopharmaceuticals appropriate for lymphoscintigraphy have ever been approved in Japan. The authors compared the pharmacokinetics of three different radiopharmaceuticals used for sentinel lymphoscintigraphy in breast cancer ( 99m Tc-labeled albumin, 99m Tc-labeled tin colloid, and 99m Tc-labeled phytic acid) and founded that the detection rate was lowest with

  10. The Scientist as Sentinel (Invited)

    Science.gov (United States)

    Oreskes, N.

    2013-12-01

    Scientists have been warning the world for some time about the risks of anthropogenic interference in the climate system. But we struggle with how, exactly, to express that warning. The norms of scientific behavior enjoin us from the communication strategies normally associated with warnings. If a scientist sounds excited or emotional, for example, it is often assumed that he has lost his capac¬ity to assess data calmly and therefore his conclusions are suspect. If the scientist is a woman, the problem is that much worse. In a recently published article my colleagues and I have shown that scientists have systematically underestimated the threat of climate change (Brysse et al., 2012). We suggested that this occurs for norma¬tive reasons: The scientific values of rationality, dispassion, and self-restraint lead us to demand greater levels of evidence in support of surprising, dramatic, or alarming conclusions than in support of less alarming conclusions. We call this tendency 'err¬ing on the side of least drama.' However, the problem is not only that we err on the side of least drama in our assessment of evidence, it's also that we speak without drama, even when our conclusions are dramatic. We speak without the emotional cadence that people expect to hear when the speaker is worried. Even when we are worried, we don't sound as if we are. In short, we are trying to act as sentinels, but we lack the register with which to do so. Until we find those registers, or partner with colleagues who are able to speak in the cadences that communicating dangers requires, our warnings about climate change will likely continue to go substantially unheeded.

  11. The Search for Hot Jupiters using Red Buttes Observatory

    Science.gov (United States)

    Sorber, Rebecca L.; Kar, Aman; Hancock, Daniel A.; Leuquire, Jacob D.; Suhaimi, Afiq; Kasper, David; Jang-Condell, Hannah

    2018-01-01

    The goal of this research is to use the University of Wyoming’s Red Buttes Observatory (RBO) to perform manual, remote, or automated observations of transiting exoplanet candidates. The data contributes to discovery of star systems that include never before identified exoplanets. RBO houses a 0.6-meter telescope and is located approximately 10 miles south of the University of Wyoming’s campus. Our targets are catalogued by the KELT (Kilodegree Extremely Little Telescope) Survey, a photometric search for transiting exoplanets around bright main sequence stars. The KELT Follow-up Network (KELT-FUN), a collaboration of small-aperture telescope users located all over the world, confirms new exoplanet candidates. As part of KELT-FUN, students use the RBO to monitor candidates identified by the KELT team. RBO typically detects transits around stars that are 8-12 in V magnitude, with transit durations of ~1-4 hours and full depth relative changes in brightness above 2 mmags. Using AstroImageJ, we process the data and we look for any indication of a transit occurrence in the processed lightcurve which might confirm the presence of the potential exoplanet. Our team has contributed over 50 light curves to KELT-FUN to date. We are able to compare our data with simultaneous observations by other members of KELT-FUN to maximize the utility of our observations. This project gives undergraduates an authentic scientific research experience, learning how to operate an observatory, process data, and participate in a scientific collaboration.

  12. Microstructure and mechanical performance of autogenously fibre laser beam welded Ti-6242 butt joints

    Energy Technology Data Exchange (ETDEWEB)

    Kashaev, Nikolai, E-mail: nikolai.kashaev@hzg.de; Pugachev, Dmitry; Ventzke, Volker; Fomin, Fedor; Burkhardt, Irmela; Enz, Josephin; Riekehr, Stefan

    2017-05-10

    This work deals with the effects of laser beam power, focus position and advance speed on the geometry, microstructure and mechanical properties such as the tensile strength and microhardness of autogenously fibre laser beam welded Ti-6Al-2Sn-4Zr-2Mo (denoted as Ti-6242) butt joints used for high temperature applications. The Ti-6242 sheet employed here is characterized by a globular (α+β) microstructure. Laser beam welded butt joints consisted of a martensitic fusion zone, inhomogeneous heat affected zones and equiaxed base materials. The microhardness increased from 330 HV 0.3 in base material to 430 HV 0.3 in fusion zone due to the martensitic transformation. Butt joints showed the base material level of strength in tensile test. The local increase in microhardness provided a shielding effect that protected the Ti-6242 butt joint against mechanical damage during the static tensile load test. The predicted critical total underfill depth that does not reduce the tensile strength of the weld was determined to be 25% of the specimen thickness. - Highlights: • Autogenous fibre LBW of Ti-6242 was successfully achieved. • Butt joints showed low levels of porosity and an appropriate seam geometry. • Base material level of strength achieved for tensile strength. • Predicted critical underfill depth is 25% of the specimen thickness.

  13. Dormaier and Chester Butte 2007 Follow-up Habitat Evaluation Procedures Report.

    Energy Technology Data Exchange (ETDEWEB)

    Ashley, Paul R.

    2008-01-01

    Follow-up habitat evaluation procedures (HEP) analyses were conducted on the Dormaier and Chester Butte wildlife mitigation sites in April 2007 to determine the number of additional habitat units to credit Bonneville Power Administration (BPA) for providing funds to enhance, and maintain the project sites as partial mitigation for habitat losses associated with construction of Grand Coulee Dam. The Dormaier follow-up HEP survey generated 482.92 habitat units (HU) or 1.51 HUs per acre for an increase of 34.92 HUs over baseline credits. Likewise, 2,949.06 HUs (1.45 HUs/acre) were generated from the Chester Butte follow-up HEP analysis for an increase of 1,511.29 habitat units above baseline survey results. Combined, BPA will be credited with an additional 1,546.21 follow-up habitat units from the Dormaier and Chester Butte parcels.

  14. Geology of Pine and Crater Buttes: two basaltic constructs on the far eastern Snake River Plain

    International Nuclear Information System (INIS)

    Mazierski, P.F.; King, J.S.

    1987-01-01

    The emplacement history and petrochemical evolution of the volcanics associated with Pine Butte, Crater Butte, and other nearby vents are developed and described. Four major vents were identified in the study area and their associated eruptive products were mapped. All of the vents show a marked physical elongation or linear orientation coincident with the observed rift set. Planetary exploration has revealed the importance of volcanic processes in the genesis and modification of extraterrestrial surfaces. Interpretation of surface features has identified plains-type basaltic volcanism in various mare regions of the Moon and the volcanic provinces of Mars. Identification of these areas with features that appear analogous to those observed in the Pine Butte area suggests similar styles of eruption and mode of emplacement. Such terrestrial analogies serve as a method to interpret the evolution of volcanic planetary surfaces on the inner planets

  15. Sentinel lymph node identification with magnetic nanoparticles

    NARCIS (Netherlands)

    Pouw, Joost Jacob

    2016-01-01

    Most solid malignancies have a tendency to spread through the lymphatic system to locoregional lymph nodes. Presence of metastasis is an important prognostic factor, and is used to determine the optimal treatment of the patient. The sentinel lymph nodes (SLNs) receive direct lymphatic drainage from

  16. CTC Sentinel. Volume 9, Issue 3

    Science.gov (United States)

    2016-03-01

    for the Caliphate,” CTC Sentinel 8:8 (2015). 28 Nicolas Beau, “Syrte, une cinquantaine de français aux cotés de Daech,” MondeAfrique, February 12...scale.”2 Earlier this month, Assistant Commissioner Mark Rowley, who oversees counterterrorism efforts for the London Metropoli- tan Police, warned

  17. FOREST AREA DERIVATION FROM SENTINEL-1 DATA

    Directory of Open Access Journals (Sweden)

    A. Dostálová

    2016-06-01

    Full Text Available The recently launched Sentinel-1A provides the high resolution Synthetic Aperture Radar (SAR data with very high temporal coverage over large parts of European continent. Short revisit time and dual polarization availability supports its usability for forestry applications. The following study presents an analysis of the potential of the multi-temporal dual-polarization Sentinel-1A data for the forest area derivation using the standard methods based on Otsu thresholding and K-means clustering. Sentinel-1 data collected in winter season 2014-2015 over a test area in eastern Austria were used to derive forest area mask with spatial resolution of 10m and minimum mapping unit of 500 m2. The validation with reference forest mask derived from airborne full-waveform laser scanning data revealed overall accuracy of 92 % and kappa statistics of 0.81. Even better results can be achieved when using external mask for urban areas, which might be misclassified as forests when using the introduced approach based on SAR data only. The Sentinel-1 data and the described methods are well suited for forest change detection between consecutive years.

  18. Land science with Sentinel-2 and Sentinel-3 data series synergy

    Science.gov (United States)

    Moreno, Jose; Guanter, Luis; Alonso, Luis; Gomez, Luis; Amoros, Julia; Camps, Gustavo; Delegido, Jesus

    2010-05-01

    Although the GMES/Sentinel satellite series were primarily designed to provide observations for operational services and routine applications, there is a growing interest in the scientific community towards the usage of Sentinel data for more advanced and innovative science. Apart from the improved spatial and spectral capabilities, the availability of consistent time series covering a period of over 20 years opens possibilities never explored before, such as systematic data assimilation approaches exploiting the time-series concept, or the incorporation in the modelling approaches of processes covering time scales from weeks to decades. Sentinel-3 will provide continuity to current ENVISAT MERIS/AATSR capabilities. The results already derived from MERIS/AATRS will be more systematically exploited by using OLCI in synergy with SLST. Particularly innovative is the case of Sentinel-2, which is specifically designed for land applications. Built on a constellation of two satellites operating simultaneously to provide 5 days geometric revisit time, the Sentinel-2 system will providing global and systematic acquisitions with high spatial resolution and with a high revisit time tailored towards the needs of land monitoring. Apart from providing continuity to Landsat and SPOT time series, the Sentinel-2 Multi-Spectral Instrument (MSI) incorporates new narrow bands around the red-edge for improved retrievals of biophysical parameters. The limitations imposed by the need of a proper cloud screening and atmospheric corrections have represented a serious constraint in the past for optical data. The fact that both Sentinel-2 and 3 have dedicated bands to allow such needed corrections for optical data represents an important step towards a proper exploitation, guarantying consistent time series showing actual variability in land surface conditions without the artefacts introduced by the atmosphere. Expected operational products (such as Land Cover maps, Leaf Area Index

  19. 75 FR 60804 - Notice of Availability of the Final Environmental Impact Statement for the West Butte Wind Power...

    Science.gov (United States)

    2010-10-01

    ... Wind Power Right-of-Way, Crook and Deschutes Counties, OR AGENCY: Bureau of Land Management, Interior... Final Environmental Impact Statement (EIS) for the West Butte Wind Power Right-of-Way and by this Notice... Register notice. FOR FURTHER INFORMATION CONTACT: Steve Storo, BLM West Butte Wind Power Right of Way...

  20. 77 FR 61020 - Notice of Availability of Final Environmental Impact Statement for the Sigurd to Red Butte No. 2...

    Science.gov (United States)

    2012-10-05

    ...; UTU-83067] Notice of Availability of Final Environmental Impact Statement for the Sigurd to Red Butte... (BLM) has prepared a Final Environmental Impact Statement (EIS) for the Sigurd to Red Butte No. 2--345...; Utah School and Institutional Trust Lands Administration; Millard, Sevier, Beaver, Iron, and Washington...

  1. 77 FR 10773 - Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines; Scheduling of...

    Science.gov (United States)

    2012-02-23

    ... Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines; Scheduling of Expedited Five-Year... orders on stainless steel butt-weld pipe fittings from Italy, Malaysia, and the Philippines would be... certificate of service. Determination.--The Commission has determined to exercise its authority to extend the...

  2. 76 FR 67146 - Stainless Steel Butt-Weld Pipe Fittings From Italy; Extension of Time Limit for Preliminary...

    Science.gov (United States)

    2011-10-31

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-475-828] Stainless Steel Butt-Weld... antidumping duty order on stainless steel butt-weld pipe fittings from Italy in the Federal Register. See... preliminary results of this review within the original time frame because it needs to obtain additional...

  3. The multispectral instrument of the Sentinel2 program

    Science.gov (United States)

    Cazaubiel, V.; Chorvalli, Vincent; Miesch, Christophe

    2017-11-01

    The Sentinel-2 program will provide a permanent record of comprehensive data to help inform the agricul-tural sector (utilisation, coverage), forestry industry (population, damage, forest fires), disaster control (management, early warning) and humanitarian relief programmes. Sentinel-2 will also be able to observe natural disasters such as floods, volcanic eruptions, subsidence and landslides. In the Sentinel-2 mission programme, Astrium in Friedrichshafen is responsible for the satellite's system design and platform, as well as for satellite integration and testing. Astrium Toulouse will supply the Multi-Spectral imaging Instrument (MSI), and Astrium Spain will be in charge of the satellite's structure and will produce its thermal equipment and cable harness. The industrial core team also comprises Jena Optronik (Germany), Boostec (France), Sener and GMV (Spain). Sentinel-2 is intended to image the Earth's landmasses from its orbit for at least 7.25 years. In addition, its onboardresources will be designed so that the mission can be prolonged by an extra five years. From 2012 onwards, the 1.1-metric-ton satellite will circle the Earth in a sun-synchronous, polar orbit at an altitude of 786kilometres, fully covering the planet's landmasses in just ten days. The multi-spectral instrument (MSI) will generate optical images in 13 spectral channels in the visible and shortwave infrared range down to a resolution of 10 metres with an image width of 290 kilometres. The instrument is composed of two main parts: • The telescope assembly , combining in one instrument both VNIR and SWIR channels, is mounted on the upper plate of the Bus • The Video and Compression Electronic Units mounted inside the Bus. This telescope is based on a Three Mirror Anastigmat optical concept. This three mirror optical combination is corrected from spherical aberration, coma and astigmatism. It provides a large field of view with very good optical quality. The telescope mirrors and

  4. A parametric study of residual stresses in multipass butt-welded stainless steel pipes

    Energy Technology Data Exchange (ETDEWEB)

    Brickstad, B. [SAQ Inspection Ltd., Stockholm (Sweden); Josefson, L. [Chalmers Univ. of Technology, Goeteborg (Sweden). Div. of Solid Mechanics

    1996-06-01

    Multipass circumferential butt-welding of stainless steel pipes is simulated numerically in a non-linear thermo-mechanical FE-analysis. In particular, the through-thickness variation at the weld and heat affected zone, of the axial and hoop stresses and their sensitivity to variation in weld parameters are studied. Recommendations are given for the through thickness variation of the axial and hoop stresses to be used when assessing the growth of surface flaws at circumferential butt welds in nuclear piping system. 31 refs, 12 tabs, 54 figs.

  5. Et cigaretskod, en donation, en renere by: A cigarette butt, a donation, a cleaner city

    OpenAIRE

    Bengtsen, Monica; Patursson, Guttormur; Nedergaard, Sofie Tarpø; Madsen, Maria Chas; Drews, Anna Ørsted; Bach, Katrine Møller

    2013-01-01

    This project concerns an explanation of the problem of cigarette butts lying in the streets of Copenhagen. By using elements of the theory of nudging we have designed an ashtray ment to pledge smokers not to throw their butt in the streets. The design is a response to a design competition published by the municipality of Copenhagen, as an attempt to be the cleanest capital in Europe by the year 2015. The core of the design presentation is in cooperation with private firms, who have obligated ...

  6. Analysis and Prediction of the Billet Butt and Transverse Weld in the Continuous Extrusion Process of a Hollow Aluminum Profile

    Science.gov (United States)

    Lou, Shumei; Wang, Yongxiao; Liu, Chuanxi; Lu, Shuai; Liu, Sujun; Su, Chunjian

    2017-08-01

    In continuous extrusions of aluminum profiles, the thickness of the billet butt and the length of the discarded extrudate containing the transverse weld play key roles in reducing material loss and improving product quality. The formation and final distribution of the billet butt and transverse weld depend entirely on the flow behavior of the billet skin material. This study examined the flow behavior of the billet skin material as well as the formation and evolution of the billet butt and the transverse weld in detail through numerical simulation and a series of experiments. In practical extrusions, even if the billet skin is removed by lathe turning shortly before extrusion, billet skin impurities are still distributed around the transverse weld and in the billet butt. The thickness of the scrap billet butt and the length of the discarded extrudate containing the transverse weld can be exactly predicted via simulation.

  7. 76 FR 43341 - Notice of Availability of the Record of Decision for the West Butte Wind Power Right-of-Way...

    Science.gov (United States)

    2011-07-20

    ... LVRWH09H0600; HAG 10-0338] Notice of Availability of the Record of Decision for the West Butte Wind Power Right... INFORMATION CONTACT: Steve Storo, BLM West Butte Wind Power Right-of-Way Project Lead: telephone (541) 416... INFORMATION: The applicant, West Butte Wind Power, LLC, filed right-of-way (ROW) application OR-065784 to...

  8. Geocoding uncertainty analysis for the automated processing of Sentinel-1 data using Sentinel-1 Toolbox software

    Science.gov (United States)

    Dostálová, Alena; Naeimi, Vahid; Wagner, Wolfgang; Elefante, Stefano; Cao, Senmao; Persson, Henrik

    2016-10-01

    One of the major advantages of the Sentinel-1 data is its capability to provide very high spatio-temporal coverage allowing the mapping of large areas as well as creation of dense time-series of the Sentinel-1 acquisitions. The SGRT software developed at TU Wien aims at automated processing of Sentinel-1 data for global and regional products. The first step of the processing consists of the Sentinel-1 data geocoding with the help of S1TBX software and their resampling to a common grid. These resampled images serve as an input for the product derivation. Thus, it is very important to select the most reliable processing settings and assess the geocoding uncertainty for both backscatter and projected local incidence angle images. Within this study, selection of Sentinel-1 acquisitions over 3 test areas in Europe were processed manually in the S1TBX software, testing multiple software versions, processing settings and digital elevation models (DEM) and the accuracy of the resulting geocoded images were assessed. Secondly, all available Sentinel-1 data over the areas were processed using selected settings and detailed quality check was performed. Overall, strong influence of the used DEM on the geocoding quality was confirmed with differences up to 80 meters in areas with higher terrain variations. In flat areas, the geocoding accuracy of backscatter images was overall good, with observed shifts between 0 and 30m. Larger systematic shifts were identified in case of projected local incidence angle images. These results encourage the automated processing of large volumes of Sentinel-1 data.

  9. Sentinel-2B image quality commissioning phase results and Sentinel2 constellation performances

    Science.gov (United States)

    Languille, F.; Gaudel, A.; Vidal, B.; Binet, R.; Poulain, V.; Trémas, T.

    2017-09-01

    In the frame of the Copernicus program of the European Commission, Sentinel-2 is a constellation of 2 satellites on a polar sun-synchronous orbit with a revisit time of 5 days (with both satellites), a high field of view - 290km, 13 spectral bands in visible and shortwave infrared, and high spatial resolution - 10m, 20m and 60m. The Sentinel-2 mission offers a global coverage over terrestrial surfaces. The satellites acquire systematically terrestrial surfaces under the same viewing conditions in order to have temporal images stacks. The first satellite was launched in June 2015 and the second in March 2017. In cooperation with the European Space Agency (ESA), the French space agency (CNES) is in charge of the image quality of the project, and so ensured the CAL/VAL commissioning phase during the months following the launch. This cooperation is also extended to routine phase as CNES supports European Space Research Institute (ESRIN) and the Sentinel-2 Mission performance Centre (MPC) for validation in geometric and radiometric image quality aspects, and in Sentinel-2 Global Reference Image (GRI) geolocation performance assessment. This paper points on geometric image quality on Sentinel-2B commissioning phase. It relates to the methods and the performances obtained, as well as the comparison between S2A and S2B. This deals with geolocation and multispectral registration. A small focus is also done on the Sentinel-2 GRI which is a set of S2A images at 10m resolution covering the whole world with a good and consistent geolocation. This ground reference leads to ensure an accurate multi-temporal registration -on refined Sentinel-2 products over GRI- which is also presented in this paper.

  10. ESA's Multi-mission Sentinel-1 Toolbox

    Science.gov (United States)

    Veci, Luis; Lu, Jun; Foumelis, Michael; Engdahl, Marcus

    2017-04-01

    The Sentinel-1 Toolbox is a new open source software for scientific learning, research and exploitation of the large archives of Sentinel and heritage missions. The Toolbox is based on the proven BEAM/NEST architecture inheriting all current NEST functionality including multi-mission support for most civilian satellite SAR missions. The project is funded through ESA's Scientific Exploitation of Operational Missions (SEOM). The Sentinel-1 Toolbox will strive to serve the SEOM mandate by providing leading-edge software to the science and application users in support of ESA's operational SAR mission as well as by educating and growing a SAR user community. The Toolbox consists of a collection of processing tools, data product readers and writers and a display and analysis application. A common architecture for all Sentinel Toolboxes is being jointly developed by Brockmann Consult, Array Systems Computing and C-S called the Sentinel Application Platform (SNAP). The SNAP architecture is ideal for Earth Observation processing and analysis due the following technological innovations: Extensibility, Portability, Modular Rich Client Platform, Generic EO Data Abstraction, Tiled Memory Management, and a Graph Processing Framework. The project has developed new tools for working with Sentinel-1 data in particular for working with the new Interferometric TOPSAR mode. TOPSAR Complex Coregistration and a complete Interferometric processing chain has been implemented for Sentinel-1 TOPSAR data. To accomplish this, a coregistration following the Spectral Diversity[4] method has been developed as well as special azimuth handling in the coherence, interferogram and spectral filter operators. The Toolbox includes reading of L0, L1 and L2 products in SAFE format, calibration and de-noising, slice product assembling, TOPSAR deburst and sub-swath merging, terrain flattening radiometric normalization, and visualization for L2 OCN products. The Toolbox also provides several new tools for

  11. Microstructure feature of friction stir butt-welded ferritic ductile iron

    International Nuclear Information System (INIS)

    Chang, Hung-Tu; Wang, Chaur-Jeng; Cheng, Chin-Pao

    2014-01-01

    Highlights: • Defect-free ferritic ductile iron joints is fabricated by FSW. • The welding nugget is composed of graphite, martensite, and recrystallized ferrite. • The graphite displays a striped pattern in the surface and advancing side. • The ferritic matrix transforms into martensite structure during welding. • High degree of plastic deformation is found on the advancing side. - Abstract: This study conducted friction stir welding (FSW) by using the butt welding process to join ferritic ductile iron plates and investigated the variations of microsturcture in the joined region formed after welding. No defects appeared in the resulting experimental weld, which was formed using a 3-mm thick ductile iron plate and tungsten carbide alloy stir rod to conduct FSW at a rotational speed of 982 rpm and traveling speed of 72 mm/min. The welding region was composed of deformed graphite, martensite phase, and dynamically recrystallized ferrite structures. In the surface region and on the advancing side (AS), the graphite displayed a striped configuration and the ferritic matrix transformed into martensite. On the retreating side (RS), the graphite surrounded by martensite remained as individual granules and the matrix primarily comprised dynamically recrystallized ferrite. After welding, diffusion increased the carbon content of the austenite around the deformed graphite nodules, which transformed into martensite during the subsequent cooling process. A micro Vickers hardness test showed that the maximum hardness value of the martensite structures in the weld was approximately 800 HV. An analysis using an electron probe X-ray microanalyzer (EPMA) indicated that its carbon content was approximately 0.7–1.4%. The peak temperature on the RS, 8 mm from the center of the weld, measured 630 °C by the thermocouple. Overall, increased severity of plastic deformation and process temperature near the upper stir zone (SZ) resulted in distinct phase transformation

  12. Modeling and control of a DC upset resistance butt welding process

    NARCIS (Netherlands)

    Naus, G.J.L.; Meulenberg, R.; Molengraft, van de M.J.G.

    2007-01-01

    This paper presents the analysis and synthesis of modeling and control of the DC upset resistance butt welding process used in rim production lines. A new control strategy is developed, enabling active control of the welding seam temperature and the upset size. As a result, set-up times and energy

  13. Gap Width Study and Fixture Design in Laser Butt-Welding

    DEFF Research Database (Denmark)

    Gong, Hui; Olsen, Flemming Ove

    .5-2.0 m/min, the laser power : 2 and 2.6 kW and the focal point position : 0 and -1.2 mm. Quality of all the butt welds are destructively tested according to ISO 13919-1.Influences of the variable process parameters to the maximum allowable gap width are observed as (1) the maximum gap width is inversely......This paper discusses some practical consideration for design of a mechanical fixture, which enables to accurately measure the width of a gap between two stainless steel workpieces and to steadfastly clamp the workpieces for butt-welding with a high power CO2 laser.With such a fixture, a series...... of butt-welding experiment is successfully carried out in order to find the maximum allowable gap width in laser butt-welding. The gap width study (GWS) is performed on the material of SST of W1.4401 (AISI 316) under various welding conditions, which are the gap width : 0.00-0.50 mm, the welding speed : 0...

  14. TIG-dressing of High Strength Butt Welded Connection. Part 2 : Physical Testing and Modelling

    NARCIS (Netherlands)

    Van Es, S.H.J.; Kolstein, M.H.; Pijpers, R.J.M.; Bijlaard, F.S.K.

    2014-01-01

    Weld improvement techniques are aimed at reducing the notch effects of welds and generally focus on two aspects: a change of geometry of the weld toe and a change of the weld residual stresses. In this paper, fatigue tests are discussed, performed on butt welded specimens in steel grades ranging

  15. TIG-dressing of high strength butt welded connection - Part 2: physical testing and modelling

    NARCIS (Netherlands)

    Es, S.H.J. van; Kolstein, M.H.; Pijpers, R.J.M.; Bijlaard, F.S.K.

    2013-01-01

    Weld improvement techniques are aimed at reducing the notch effects of welds and generally focus on two aspects: a change of geometry of the weld toe and a change of the weld residual stresses. In this paper, fatigue tests are discussed, performed on butt welded specimens in steel grades ranging

  16. Characterizing butt-rot fungi on USA-affiliated islands in the western Pacific

    Science.gov (United States)

    Phil Cannon; Ned B. Klopfenstein; Robert L. Schlub; Mee-Sook Kim; Yuko Ota; Norio Sahashi; Roland J. Quitugua; John W. Hanna; Amy L. Ross-Davis; J. D. Sweeney

    2014-01-01

    Ganoderma and Phellinus are genera that commonly cause tree butt-rot on USA-affiliated islands of the western Pacific. These fungal genera can be quite prevalent, especially in older mangrove stands. Although the majority of infections caused by these fungi lead to severe rotting of the heartwood, they typically do not directly kill the living tissues of the sapwood,...

  17. Ultrasonic wave propagation in real-life austenitic V-butt welds: Numerical modeling and validation

    International Nuclear Information System (INIS)

    Hannemann, R.; Marklein, R.; Langenberg, K. J.; Schurig, C.; Koehler, B.; Walte, F.

    2000-01-01

    In nondestructive testing the evaluation of austenitic steel welds with ultrasound is a commonly used method. But, since the wave propagation, scattering, and diffraction effects in such complicated media are hardly understood, computer simulations are very helpful to increase the knowledge of the physical phenomena in such samples. A particularly powerful numerical time domain modeling tool is the well established Elastodynamic Finite Integration Technique (EFIT). Recently, EFIT has been extended to simulate elastic waves in inhomogeneous anisotropic media. In this paper, the step-by-step evaluation of ultrasonic wave propagation in inhomogeneous anisotropic media will be described and the results will be validated against measurements. As a simplified model, a V-butt weld with perpendicular grain structure is investigated. The coincidence between the B Scans of the simulation and the measurement of an idealized V-butt weld is remarkable and even effects predicted by theory and simulation - the appearance of two coupled quasi-SV waves - can be observed. As a next step, an improved and more realistic model of the grain orientation inside the V-butt weld is introduced. This model has been implemented in the EFIT code and has been validated against measurements. For this verification, measured and simulated B-Scans for a real-life V-butt weld have been compared and a significant coincidence has been observed. Furthermore, the main pulses in the B-Scans are interpreted by analyzing the snapshot-movies of the wavefronts

  18. 77 FR 13072 - Salmon-Challis National Forest, Butte, Custer and Lemhi Counties, ID, Supplemental Environmental...

    Science.gov (United States)

    2012-03-05

    ... DEPARTMENT OF AGRICULTURE Forest Service Salmon-Challis National Forest, Butte, Custer and Lemhi Counties, ID, Supplemental Environmental Impact Statement to the 2009 Salmon- Challis National Forest... of intent to prepare a supplemental environmental impact statement. SUMMARY: The Salmon-Challis...

  19. Geology of the Pumpkin Buttes Area of the Powder River Basin, Campbell and Johnson Counties, Wyoming

    Science.gov (United States)

    Sharp, William Neil; White, Amos McNairy

    1956-01-01

    About 200 uranium occurrences have been examined in the Pumpkin Buttes area, Wyoming. Uranium minerals are visible at most of these places and occur in red and buff sandstone lenses in the Wasatch formation of Eocene age. The uranium minerals are disseminated in buff sandstone near red sandstone, and also occur in red sandstone in manganese oxide concretions and uraninite concretions.

  20. A study of fatigue life distribution of butt-welded joints

    International Nuclear Information System (INIS)

    Sakai, Tatsuo; Fujitani, Keizo; Kikuchi, Toshiro; Tanaka, Takao.

    1981-01-01

    Various kinds of welded joints are being used in many structures such as ships, bridges and constructions. It is important in reliability analysis of such structures to clarify the statistical fatigue property of the welded joints. In this study, fatigue tests were carried out on the butt-welded joints of SM50A steel and a theoretical interpretation on the fatigue life distribution was attempted, assuming that a butt-welded joint is composed of a number of sliced specimens with different fatigue strengths. Main results obtained are summarized as follows; (1) The median crack initiation life of the butt-welded joint specimens coincided with that of the sliced specimens, when the crack initiation was defined by a 0.2 mm crack in the sliced specimens or the equivalent state of stress intensity factor in the joint specimens. (2) The distribution of crack initiation lives of the butt-welded joints can be theoretically derived by combining the concept of extreme distribution and the distribution model on the number of fatigue cracks. The theoretical distribution of crack initiation lives of the joints is in good agreement with the general trend of the experimental results. (3) If the distribution of crack initiation lives and the crack growth law are given experimentally, one can obtain analytically the distribution of final fatigue lives. The fatigue life distribution of the sliced specimens can be explained by the theory established in this study. (author)

  1. Teacher's Guide to Architectural Styles. Skinner's Butte Historical District. Revised Edition.

    Science.gov (United States)

    Bauer, Mary; Neimand, Hahn

    This document is a teacher's guide to the historic buildings of Eugene, Oregon. Eighteen buildings in the Skinner's Butte Historical District are highlighted, including the U.S. Post Office, the Eagles Building, the Lane Hotel, the Oregon Electric Depot, the Southern Pacific Railroad Depot, and several houses. For each structure there is a brief…

  2. SENTINEL-2 LEVEL 1 PRODUCTS AND IMAGE PROCESSING PERFORMANCES

    OpenAIRE

    S. J. Baillarin; A. Meygret; C. Dechoz; B. Petrucci; S. Lacherade; T. Tremas; C. Isola; P. Martimort; F. Spoto

    2012-01-01

    In partnership with the European Commission and in the frame of the Global Monitoring for Environment and Security (GMES) program, the European Space Agency (ESA) is developing the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. While ensuring data continuity of former SPOT and LANDSAT multi-spectral missions, Sentinel-2 wil...

  3. RTS effect detection in Sentinel-4 data

    Science.gov (United States)

    Candeias, Henrique; Gnata, Xavier; Harlander, Maximilian; Hermsen, Markus; Hohn, Rüdiger; Riedl, Stefan; Skegg, Michael; Williges, Christian; Reulke, Ralf

    2017-09-01

    The future ESA Earth Observation Sentinel-4/UVN is a high resolution spectrometer intended to fly on board a Meteosat Third Generation Sounder (MTG-S) platform, placed in a geostationary orbit. The main objective of this optical mission is to continuously monitor the air quality over Europe in near-real time. The Sentinel-4/UVN instrument operates in three wavelength bands: Ultraviolet (UV: 305-400 nm), Visible (VIS: 400- 500 nm) and Near-infrared (NIR: 750-775 nm). Two dedicated CCD detector have been developed to be used in the Focal Plane Subsystems (FPS), one for the combined UV and VIS band, the other covering the NIR band. Being a high resolution spectrometer with challenging radiometric accuracy requirements, both on spectral and spatial dimensions, an effect such the Random Telegraph Signal (RTS) can represent a relevant contribution for the complete system accuracy. In this work we analyze the RTS effect on data acquired during the FPS testing campaign with qualification models for the Sentinel-4/UVN detectors. This test campaign has been performed in late 2016. The strategy for the impact assessment of RTS is to measure the effect at room temperature and then to extrapolate the results to the at instrument operational temperature. This way, very-long lasting data acquisitions could be avoided since the RTS frequency is much lower at cryogenic temperatures. A reliable technique for RTS effect detection has been developed in order to characterize the signal levels amplitude and occurrence frequencies (flipping rate). We demonstrate the residual impact of the RTS on the global In-Orbit Sentinel-4/UVN instrument performance and products accuracy.

  4. Cigarettes Butts and the Case for an Environmental Policy on Hazardous Cigarette Waste

    Directory of Open Access Journals (Sweden)

    Richard Barnes

    2009-05-01

    Full Text Available Discarded cigarette butts are a form of non-biodegradable litter. Carried as runoff from streets to drains, to rivers, and ultimately to the ocean and its beaches, cigarette filters are the single most collected item in international beach cleanups each year. They are an environmental blight on streets, sidewalks, and other open areas. Rather than being a protective health device, cigarette filters are primarily a marketing tool to help sell ‘safe’ cigarettes. They are perceived by much of the public (especially current smokers to reduce the health risks of smoking through technology. Filters have reduced the machine-measured yield of tar and nicotine from burning cigarettes, but there is controversy as to whether this has correspondingly reduced the disease burden of smoking to the population. Filters actually may serve to sustain smoking by making it seem less urgent for smokers to quit and easier for children to initiate smoking because of reduced irritation from early experimentation. Several options are available to reduce the environmental impact of cigarette butt waste, including developing biodegradable filters, increasing fines and penalties for littering butts, monetary deposits on filters, increasing availability of butt receptacles, and expanded public education. It may even be possible to ban the sale of filtered cigarettes altogether on the basis of their adverse environmental impact. This option may be attractive in coastal regions where beaches accumulate butt waste and where smoking indoors is increasingly prohibited. Additional research is needed on the various policy options, including behavioral research on the impact of banning the sale of filtered cigarettes altogether.

  5. Cigarettes butts and the case for an environmental policy on hazardous cigarette waste.

    Science.gov (United States)

    Novotny, Thomas E; Lum, Kristen; Smith, Elizabeth; Wang, Vivian; Barnes, Richard

    2009-05-01

    Discarded cigarette butts are a form of non-biodegradable litter. Carried as runoff from streets to drains, to rivers, and ultimately to the ocean and its beaches, cigarette filters are the single most collected item in international beach cleanups each year. They are an environmental blight on streets, sidewalks, and other open areas. Rather than being a protective health device, cigarette filters are primarily a marketing tool to help sell 'safe' cigarettes. They are perceived by much of the public (especially current smokers) to reduce the health risks of smoking through technology. Filters have reduced the machine-measured yield of tar and nicotine from burning cigarettes, but there is controversy as to whether this has correspondingly reduced the disease burden of smoking to the population. Filters actually may serve to sustain smoking by making it seem less urgent for smokers to quit and easier for children to initiate smoking because of reduced irritation from early experimentation. Several options are available to reduce the environmental impact of cigarette butt waste, including developing biodegradable filters, increasing fines and penalties for littering butts, monetary deposits on filters, increasing availability of butt receptacles, and expanded public education. It may even be possible to ban the sale of filtered cigarettes altogether on the basis of their adverse environmental impact. This option may be attractive in coastal regions where beaches accumulate butt waste and where smoking indoors is increasingly prohibited. Additional research is needed on the various policy options, including behavioral research on the impact of banning the sale of filtered cigarettes altogether.

  6. Persistent Scatterer Interferometry using Sentinel-1 Data

    Science.gov (United States)

    Monserrat, Oriol; Crosetto, Michele; Devanthery, Nuria; Cuevas-Gonzalez, Maria; Qihuan, Huang; Barra, Anna; Crippa, Bruno

    2016-04-01

    This work will be focused on the deformation measurement and monitoring using SAR imagery from the C-band Sentinel-1, a space mission funded by the European Union and carried out by the European Space Agency (ESA) within the Copernicus Programme. The work will firstly address the data processing and analysis procedure implemented by the authors. This includes both Persistent Scatterer Interferometry (PSI) tools to analyse large stacks of SAR images (say, typically more than 20 images), and Differential SAR Interferometry (DInSAR) tools to analyse short SAR image stacks. The work will discuss the characteristics of the main products derived by using Sentinel-1 DInSAR and PSI: deformation maps, deformation velocity maps, deformation time series, residual topographic error, etc. The analysis will be carried out over different types of land use area, e.g. urban, peri-urban and rural areas. The deformation monitoring based on Sentinel-1 data will be compared with the monitoring based on data from pre-existing missions, e.g. C-band ERS and Envisat, X-band TerraSAR-X and CosmoSkyMed, etc. The comparison will concern different study areas, mainly located in Italy and Spain.

  7. Canonical analysis of sentinel-1 radar and sentinel-2 optical data

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Larsen, Rasmus

    2017-01-01

    This paper gives results from joint analyses of dual polarimety synthetic aperture radar data from the Sentinel-1 mission and optical data from the Sentinel-2 mission. The analyses are carried out by means of traditional canonical correlation analysis (CCA) and canonical information analysis (CIA......). Where CCA is based on maximising correlation between linear combinations of the two data sets, CIA maximises mutual information between the two. CIA is a conceptually more pleasing method for the analysis of data with very different modalities such as radar and optical data. Although a little...

  8. The Sentinel satellites revolutionise environmental observation; Los satelites Sentinel revolucionan la observacion medioambiental

    Energy Technology Data Exchange (ETDEWEB)

    River, A.

    2016-08-01

    Europe has in orbit three Sentinel satellites that are the backbone of the ambitious Copernicus system. Aimed at revolutionising environmental observation from both the scientific and commercial points of view, their objective is to capture massive volumes of data on the Earth with a view to ensuring progress in research into climate change, the oceans and the evolution of ice formations. (Author)

  9. Intraoperative examination of sentinel lymph nodes using scrape ...

    African Journals Online (AJOL)

    2014-08-03

    Aug 3, 2014 ... Background. In breast cancer, sentinel lymph node biopsy (SLNB) is widely used to assess the axilla when the nodes appear normal on palpation and ultrasonography. When the sentinel lymph nodes (SLNs) are negative, no further dissection is required. Surgical dissection or radiotherapy of the axilla is ...

  10. Sentinel lymphnode in breast cancer: an experience with 53 cases

    International Nuclear Information System (INIS)

    Abreu, Benedita Andrade Leal de; Melo, Nayana Alves de Brito; Abreu, Evandro Leal de; Vieira, Carlos Sabas; Abreu, Everardo Leal de; Universidade Federal do Piaui, Maranhao, PI

    2007-01-01

    The value of sentinel lymphnode biopsy or selective linfadenectomy in assessing axillary status in breast carcinoma is well established in medical literature. This work presents a brief study from our preliminary experience with 53 patients submitted to pre-surgical lymphoscintigraphy and intraoperatory detection of sentinel lymphnode and compares our records with those of current medical literature. (author)

  11. Sentinel lymphnode in breast cancer: an experience with 53 cases

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Benedita Andrade Leal de; Melo, Nayana Alves de Brito; Abreu, Evandro Leal de; Vieira, Carlos Sabas; Abreu, Everardo Leal de [Universidade Estadual do Piaui, Maranhao, PI (Brazil). Centro Bionuclear de Diagnostico; Universidade Federal do Piaui, Maranhao, PI (Brazil). Hospital Sao Marco; E-mail: bionuclear@uol.com.br

    2007-09-15

    The value of sentinel lymphnode biopsy or selective linfadenectomy in assessing axillary status in breast carcinoma is well established in medical literature. This work presents a brief study from our preliminary experience with 53 patients submitted to pre-surgical lymphoscintigraphy and intraoperatory detection of sentinel lymphnode and compares our records with those of current medical literature. (author)

  12. Intraoperative examination of sentinel lymph nodes using scrape ...

    African Journals Online (AJOL)

    Background. In breast cancer, sentinel lymph node biopsy (SLNB) is widely used to assess the axilla when the nodes appear normal on palpation and ultrasonography. When the sentinel lymph nodes (SLNs) are negative, no further dissection is required. Surgical dissection or radiotherapy of the axilla is indicated for ...

  13. Sentinel lymph node biopsy in breast cancer and melanoma

    NARCIS (Netherlands)

    Doting, Meintje Hylkje Edwina

    2007-01-01

    Summary and conclusions In the introduction, a short overview of the development of the sentinel lymph node biopsy concept is presented. In addition to melanoma and breast cancer, the usefulness of sentinel lymph node biopsy as a surgical assessment method for squamous cell carcinoma of penis and

  14. Sentinel lymph nodes in cancer of the oral cavity

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Christensen, Rikke Kølby; Sørensen, Jens Ahm

    2007-01-01

    when compared with (B) step-sectioning and immunostaining of the entire sentinel lymph node at 250 microM levels. METHODS: Forty patients with T1/T2 cN0 oral cancer were enrolled. Three patients were excluded. In one patient no sentinel lymph node was identified. The remaining two had unidentified...

  15. California Air Quality State Implementation Plans; Final Approval; Butte County Air Quality Management District; Stationary Source Permits

    Science.gov (United States)

    EPA is taking final action to approve a revision to the Butte County Air Quality Management District (BCAQMD) portion of the California State Implementation Plan (SIP). This revision concerns the District's New Source Review (NSR) permitting program.

  16. SENTINEL-1 and SENTINEL-2 Data Fusion for Wetlands Mapping: Balikdami, Turkey

    Science.gov (United States)

    Kaplan, G.; Avdan, U.

    2018-04-01

    Wetlands provide a number of environmental and socio-economic benefits such as their ability to store floodwaters and improve water quality, providing habitats for wildlife and supporting biodiversity, as well as aesthetic values. Remote sensing technology has proven to be a useful and frequent application in monitoring and mapping wetlands. Combining optical and microwave satellite data can help with mapping and monitoring the biophysical characteristics of wetlands and wetlands` vegetation. Also, fusing radar and optical remote sensing data can increase the wetland classification accuracy. In this paper, data from the fine spatial resolution optical satellite, Sentinel-2 and the Synthetic Aperture Radar Satellite, Sentinel-1, were fused for mapping wetlands. Both Sentinel-1 and Sentinel-2 images were pre-processed. After the pre-processing, vegetation indices were calculated using the Sentinel-2 bands and the results were included in the fusion data set. For the classification of the fused data, three different classification approaches were used and compared. The results showed significant improvement in the wetland classification using both multispectral and microwave data. Also, the presence of the red edge bands and the vegetation indices used in the data set showed significant improvement in the discrimination between wetlands and other vegetated areas. The statistical results of the fusion of the optical and radar data showed high wetland mapping accuracy, showing an overall classification accuracy of approximately 90 % in the object-based classification method. For future research, we recommend multi-temporal image use, terrain data collection, as well as a comparison of the used method with the traditional image fusion techniques.

  17. Estimation of dose and exposure at sentinel node study

    International Nuclear Information System (INIS)

    Skopljak, A.; Kucukalic-Selimovic, E.; Beslic, N.; Begic, A.; Begovic-Hadzimuratovic, S.; Drazeta, Z.; Beganovic, A.

    2005-01-01

    The purpose of this study was to estimate the dose end exposure in staff involved in sentinel node procedure for breast cancer patients. The Institute of Nuclear Medicine in Sarajevo uses a protocol for lymphoscintigraphy of the sentinel node whereby 13 MBq of 9 9mT c nanocoll are used. In this study, we measured radiation doses and exposure of a nuclear medicine physician and a technologist, as well as a surgeon performing sentinel node lymphoscintigraphy and biopsy. Dose and exposure were calculated using the equation in which we have gamma constant for 9 9mT c. Calculations were made for different times of exposure and distance. In Table 1. we estimated the dose and exposure during sentinel node study. Radiation levels were very low and the most exposed hospital staff performing sentinel node study were nuclear medicine physicians. The doses on the hands of surgeons were negligible 8 hours after exposure.(author)

  18. Development of radiographic technique for examining k-type butt weld

    International Nuclear Information System (INIS)

    Barui, K.L.; Bhattacharyya, B.

    1983-01-01

    An attempt is made to develop a radiographic technique for examining K-type full penetration butt joints in heavy duty crane girders. The existing standard techniques of radiographic examination is found to be unsuitable to assess the internal defects properly. The examination technique reported here is successful in detecting not only the nature of the internal defects but also their degree of severities - from which clues for avoiding the most probable defects can be found out. The results of radiographic examination applied on the K-type butt joints of heavy duty crane girders have been discussed and it is specified that the acceptable limit of the defects must lie between 'blue' and 'green' according to the IIW colour code. Much work is yet to be done before standard specifications regarding the acceptibility of the defects in the actual job can be formulated. (author)

  19. A new method to butt weld pipes with laser at different angles

    International Nuclear Information System (INIS)

    Gualini, M.M.S.

    1999-01-01

    Laser butt welding of pipes at different angles may be cumbersome and may require very expensive tooling. The pipe size may not allow using the laser for large volume throughputs. We propose a rotary optical head composed by an adjustable focus lens system and two reflecting mirrors. The laser beam is bent at 90 deg. C. so that weld can be performed inwards outwards. The optic head design compensates the rotary backlash and vibrations, like a penta prism thus ensuring a perfect follow up of the weld track. The optic head can be inclined at 45 deg. C. to laser butt weld pipe each other at 90 deg. C. In this case the laser beam focus position is computer controlled in order to keep the focus point always on the elliptical weld profile. The paper covers theoretical and practical aspects of the proposed device. (author)

  20. Wrought stainless steel butt-welding fittings: including reference to other corrosion resistant materials - approved 1971

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    ANSI B16.9 is the American Standard for steel butt-welding fittings and although not so stated, it is implied that its scope deals primarily with the schedules of wall thicknesses which are common to carbon steel and the grades of alloy steel piping that are selected for pressure and temperature considerations. The purpose of this standard is to provide industry with a set of dimensional standards for butt-welding fittings that can be used with these light wall pipes of corrosion resisting materials. The center-to-end dimensions of all fittings are identical with those in ANSI B16.9 which give to industry the advantage of uniform design room practice and a maximum utilization of existing die equipment. The only departure from this is in the lap-joint stub end where for purposes of economy the face-to-end of the product has been reduced for use with thin wall piping

  1. Land use classification from Sentinel-2 imagery

    OpenAIRE

    Borràs, J.; Delegido, J.; Pezzola, A.; Pereira, M.; Morassi, G.; Camps-Valls, G.

    2017-01-01

    [EN] Sentinel-2 (S2), a new ESA satellite for Earth observation, accounts with 13 bands which provide high-quality radiometric images with an excellent spatial resolution (10 and 20 m) ideal for classification purposes. In this paper, two objectives have been addressed: to determine the best classification method for S2, and to quantify its improve-ment with respect to the SPOT operational mission. To do so, four classifiers (LDA, RF, Decision Trees, K-NN) have been selected and applied to tw...

  2. Vision and spectroscopic sensing for joint tracing in narrow gap laser butt welding

    Science.gov (United States)

    Nilsen, Morgan; Sikström, Fredrik; Christiansson, Anna-Karin; Ancona, Antonio

    2017-11-01

    The automated laser beam butt welding process is sensitive to positioning the laser beam with respect to the joint because a small offset may result in detrimental lack of sidewall fusion. This problem is even more pronounced in case of narrow gap butt welding, where most of the commercial automatic joint tracing systems fail to detect the exact position and size of the gap. In this work, a dual vision and spectroscopic sensing approach is proposed to trace narrow gap butt joints during laser welding. The system consists of a camera with suitable illumination and matched optical filters and a fast miniature spectrometer. An image processing algorithm of the camera recordings has been developed in order to estimate the laser spot position relative to the joint position. The spectral emissions from the laser induced plasma plume have been acquired by the spectrometer, and based on the measurements of the intensities of selected lines of the spectrum, the electron temperature signal has been calculated and correlated to variations of process conditions. The individual performances of these two systems have been experimentally investigated and evaluated offline by data from several welding experiments, where artificial abrupt as well as gradual deviations of the laser beam out of the joint were produced. Results indicate that a combination of the information provided by the vision and spectroscopic systems is beneficial for development of a hybrid sensing system for joint tracing.

  3. A Vision-Aided 3D Path Teaching Method before Narrow Butt Joint Welding.

    Science.gov (United States)

    Zeng, Jinle; Chang, Baohua; Du, Dong; Peng, Guodong; Chang, Shuhe; Hong, Yuxiang; Wang, Li; Shan, Jiguo

    2017-05-11

    For better welding quality, accurate path teaching for actuators must be achieved before welding. Due to machining errors, assembly errors, deformations, etc., the actual groove position may be different from the predetermined path. Therefore, it is significant to recognize the actual groove position using machine vision methods and perform an accurate path teaching process. However, during the teaching process of a narrow butt joint, the existing machine vision methods may fail because of poor adaptability, low resolution, and lack of 3D information. This paper proposes a 3D path teaching method for narrow butt joint welding. This method obtains two kinds of visual information nearly at the same time, namely 2D pixel coordinates of the groove in uniform lighting condition and 3D point cloud data of the workpiece surface in cross-line laser lighting condition. The 3D position and pose between the welding torch and groove can be calculated after information fusion. The image resolution can reach 12.5 μm. Experiments are carried out at an actuator speed of 2300 mm/min and groove width of less than 0.1 mm. The results show that this method is suitable for groove recognition before narrow butt joint welding and can be applied in path teaching fields of 3D complex components.

  4. Summary of investigations of uranium deposits in the Pumpkin Buttes area, Johnson and Campbell Counties, Wyoming

    Science.gov (United States)

    Troyer, Max L.; McKay, Edward J.; Soister, Paul E.; Wallace, Stewart R.

    1954-01-01

    Uranium minerals were discovered in the Pumpkin Buttes area, Campbell and Johnson Counties, Wyo., by the U. S. Geological Survey in October 1951. From June to November 1952, an area of about 750 square miles was examined for uranium deposits, and 211 localities having abnormally high radioactivity were found; uranium minerals are visible at 121 of these localities. All known uranium mineralization in the area is restricted to sandstones of the Wasatch formation, except sparsely disseminated uranium in the sandstone of the White River formation, which caps the Pumpkin Buttes, mid several localities on the Great Pine Ridge southwest of the Pumpkin Buttes where iron-saturated sandstone and clinker in the Fort Union formation have above-normal radioactivity. The uranium occurrences in the Wasatch formation are in a red sandstone zone 450 to 900 feet above the base of the formation and are of two types: small concretionary masses of uranium, iron, manganese and vanadium minerals in sandstone, and irregular zones in which uranium minerals are disseminated in sandstone. The second type is usually larger but of lower grade than the first. Most of the localities at which uranium occurs are in a north-trending belt about 60 miles long and 18 miles in maximum width.

  5. A Demonstration System for Capturing Geothermal Energy from Mine Waters beneath Butte, Montana

    Energy Technology Data Exchange (ETDEWEB)

    Blackketter, Donald [Montana Tech of the Univ. of Montana, Butte, MT (United States)

    2015-06-01

    Executive Summary An innovative 50-ton ground-source heat pump (GSHP) system was installed to provide space heating and cooling for a 56,000 square foot (5,200 square meter) building in Butte Montana, in conjunction with its heating and chiller systems. Butte is a location with winter conditions much colder than the national average. The GSHP uses flooded mine waters at 78F (25C) as the heat source and heat sink. The heat transfer performance and efficiency of the system were analyzed using data from January through July 2014. This analysis indicated that for typical winter conditions in Butte, Montana, the GSHP could deliver about 88% of the building’s annual heating needs. Compared with a baseline natural-gas/electric system, the system demonstrated at least 69% site energy savings, 38% source energy savings, 39% carbon dioxide emissions reduction, and a savings of $17,000 per year (40%) in utility costs. Assuming a $10,000 per ton cost for installing a production system, the payback period at natural gas costs of $9.63/MMBtu and electricity costs of $0.08/kWh would be in the range of 40 to 50 years. At higher utility prices, or lower installation costs, the payback period would obviously be reduced.

  6. Treefall Gap Mapping Using Sentinel-2 Images

    Directory of Open Access Journals (Sweden)

    Iván Barton

    2017-11-01

    Full Text Available Proper knowledge about resources in forest management is fundamental. One of the most important parameters of forests is their size or spatial extension. By determining the area of treefall gaps inside the compartments, a more accurate yield can be calculated and the scheduling of forestry operations could be planned better. Several field- and remote sensing-based approaches are in use for mapping but they provide only static measurements at high cost. The Earth Observation satellite mission Sentinel-2 was put in orbit as part of the Copernicus programme. With the 10-m resolution bands, it is possible to observe small-scale forestry operations like treefall gaps. The spatial extension of these gaps is often less than 200 m2, thus their detection can only be done on sub-pixel level. Due to the higher temporal resolution of Sentinel-2, multiple observations are available in a year; therefore, a time series evaluation is possible. The modelling of illumination can increase the accuracy of classification in mountainous areas. The method was tested on three deciduous forest sites in the Börzsöny Mountains in Hungary. The area evaluation produced less than 10% overestimation with the best possible solutions on the sites. The presented work shows a low-cost method for mapping treefall gaps which delivers annual information about the gap area in a deciduous forest.

  7. Feasibility of sentinel node lymphoscintigraphy in stage I testicular cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, Pieter J.; Nieweg, Omgo E. [Department of Surgery, Netherlands Cancer Institute, Amsterdam (Netherlands); Horenblas, Simon [Department of Urology, Netherlands Cancer Institute, Amsterdam (Netherlands); Olmos, Renato Valdes A.; Hoefnagel, Cornelis A. [Department of Nuclear Medicine, The Netherlands Cancer Institute, Amsterdam (Netherlands)

    2002-05-01

    The aim of this study was to investigate the feasibility of lymphoscintigraphy for sentinel node identification in testicular cancer. Five patients with clinical stage I testicular cancer were prospectively included. A single dose of technetium-99m nanocolloid (mean dose 99 MBq, volume 0.2 ml) was injected into the funiculus in the first patient and into the testicular parenchyma in the following four patients. Dynamic lymphoscintigraphy was performed over 10 min, followed by early and late static images after 15 min and 2 to 24 h, respectively. Lymphoscintigraphy was followed by laparoscopic sentinel node biopsy on the same day in the last two patients using patent blue dye and an endoscopic gamma probe. The funicular administration route showed five hot spots in the right inguinal region after 2 h. Intratesticular administration resulted in sentinel node visualisation in three of the four patients. Dynamic images showed afferent lymphatic vessels to one sentinel node in the left para-aortic region in two patients and two sentinel nodes in the left para-aortic region in another patient. Sentinel nodes were intraoperatively identified in one of two patients who underwent laparoscopic exploration. It is concluded that lymphoscintigraphy for sentinel node identification is feasible in stage I testicular cancer using intratesticular radiocolloid administration. (orig.)

  8. Sentinel Node Biopsy in Melanoma: A Short Update

    Science.gov (United States)

    Ferrara, Gerardo; Partenzi, Antonietta; Filosa, Alessandra

    2018-01-01

    Several controversies are still ongoing about sentinel node biopsy in melanoma. It is basically a staging procedure for melanoma > 0.75 mm in thickness or for thinner melanoma in the presence of ulceration, high mitotic rate, and/or lymphovascular invasion. Complete lymph node dissection after a positive sentinel node can also allow a better locoregional disease control but seems not to prevent the development of distant metastases. The use of sentinel node biopsy in atypical Spitz tumors should be discouraged because of their peculiar biological properties. PMID:29719827

  9. Processing Sentinel-2 data with ATCOR

    Science.gov (United States)

    Pflug, Bringfried; Makarau, Aliaksei; Richter, Rudolf

    2016-04-01

    Atmospheric correction of satellite images is necessary for many applications of remote sensing. Among them are applications for agriculture, forestry, land cover and land cover change, urban mapping, emergency and inland water. ATCOR is a widely used atmospheric correction tool which can process data of many optical satellite sensors, for instance Landsat, Sentinel-2, SPOT and RapidEye. ATCOR includes a terrain and adjacency correction of satellite images and several special algorithms like haze detection, haze correction, cirrus correction, de-shadowing and empirical methods for BRDF correction. The atmospheric correction tool ATCOR starts with an estimation of the vertical column Aerosol Optical Thickness (AOT550) at 550 nm. The mean uncertainty of the ATCOR-AOT550-estimation was estimated using Landsat and RapidEye data by direct comparison with sunphotometer data as a reference. For Landsat and RapidEye the uncertainty is ΔAOT550nm ≈ 0.03±0.02 for cloudless conditions with a cloud+haze fraction below 1%. Inclusion of cloudy and hazy satellite images into the analysis results in mean ΔAOT550nm ≈ 0.04±0.03 for both RapidEye and Landsat imagery. About 1/3 of the samples perform with the AOT uncertainty better than 0.02 and about 2/3 perform with AOT uncertainty better than 0.05. An accuracy of the retrieved surface reflectance of ±2% (for reflectance reflectance units (for reflectance > 40%) can be achieved for flat terrain, and avoiding the specular and backscattering regions. ATCOR also supports the processing of Sentinel-2 data. First results of processing S2 data and a comparison with AERONET AOT values will be presented.

  10. Sentinel lymph node detection in canine oncological patients

    International Nuclear Information System (INIS)

    Balogh, L.; Andocs, G.; Mathe, D.

    2002-01-01

    Sentinel lymph node detection was investigated in dogs with spontaneously occurring tumours. In this pilot study, 24 client-owned spontaneously tumorous dogs presented for sentinel lymph node detection. A multiple method was used with a nuclear medicine technique (injection of 99mT c human serum albumin colloid) with scintigraphy and intraoperative guidance, and blue dye injection. Of the 35 lymph nodes histologically demonstrated to contain metastases, 34 (97%) were found by radioguided surgery, which means that one would have been missed in the intraoperative localisation process; 31 nodes (89%) were clearly visualised in the gamma camera images; only 27 (77%) were blue-stained by vital dye; a mere 8 lymph nodes (23%) were enlarged and therefore easily detectable by palpation. Data obtained from the harmless application of the sentinel node concept are useful for the radiopharmaceutist. The sentinel lymph node concept is well applicable in the veterinary clinic. (author)

  11. Incorporation of cigarette butts into nests reduces nest ectoparasite load in urban birds: new ingredients for an old recipe?

    Science.gov (United States)

    Suárez-Rodríguez, Monserrat; López-Rull, Isabel; Garcia, Constantino Macías

    2013-02-23

    Birds are known to respond to nest-dwelling parasites by altering behaviours. Some bird species, for example, bring fresh plants to the nest, which contain volatile compounds that repel parasites. There is evidence that some birds living in cities incorporate cigarette butts into their nests, but the effect (if any) of this behaviour remains unclear. Butts from smoked cigarettes retain substantial amounts of nicotine and other compounds that may also act as arthropod repellents. We provide the first evidence that smoked cigarette butts may function as a parasite repellent in urban bird nests. The amount of cellulose acetate from butts in nests of two widely distributed urban birds was negatively associated with the number of nest-dwelling parasites. Moreover, when parasites were attracted to heat traps containing smoked or non-smoked cigarette butts, fewer parasites reached the former, presumably due to the presence of nicotine. Because urbanization changes the abundance and type of resources upon which birds depend, including nesting materials and plants involved in self-medication, our results are consistent with the view that urbanization imposes new challenges on birds that are dealt with using adaptations evolved elsewhere.

  12. High risk of non-sentinel node metastases in a group of breast cancer patients with micrometastases in the sentinel node

    DEFF Research Database (Denmark)

    Tvedskov, Tove Filtenborg; Jensen, Maj-Britt; Lisse, Ida Marie

    2012-01-01

    Axillary lymph node dissection (ALND) in breast cancer patients with positive sentinel nodes is under debate. We aimed to establish two models to predict non-sentinel node (NSN) metastases in patients with micrometastases or isolated tumor cells (ITC) in sentinel nodes, to guide the decision for ...

  13. Sentinel lymph nodes in cancer of the oral cavity

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Krogdahl, Annelise

    2005-01-01

    BACKGROUND: Sentinel lymph node biopsy, step sectioning and immunohistochemistry have changed detection of tumour deposits. Isolated tumour cells (ITC) are detected more frequently than earlier because of a changed level of detection. METHODS: A total of 108 sentinel lymph nodes from 30 patients ...... with macrometastasis, five with micrometastasis and two with ITC. CONCLUSION: The ITC are probably precursors of micrometastasis waiting to grow and should be treated as such. Benign inclusions and dendritic cells did not cause problems, but can mimic ITC....

  14. Immunolymphoscintigraphy for metastatic sentinel nodes: test of a model

    DEFF Research Database (Denmark)

    Chakera, A H; Nielsen, B S; Madsen, J

    2011-01-01

    Aim. To develop a method and obtain proof-of-principle for immunolymphoscintigraphy for identification of metastatic sentinel nodes. Methods. We selected one of four tumour-specific antibodies against human breast cancer and investigated (1), in immune-deficient (nude) mice with xenograft human b...... in healthy rabbits. Results and Conclusion. Our paper suggests the theoretical possibility of a model of dual isotope immuno-lymphoscintigraphy for noninvasive, preoperative, malignant sentinel node imaging....

  15. Butt Weldability for SS400 Using Laser-Arc Hybrid Welding

    International Nuclear Information System (INIS)

    Kim, Jong Do; Myoung, Gi Hoon; Park, Duck; Myoung, Gi Hoon; Park, In Duck

    2016-01-01

    This study presents results of an experimental investigation of the laser-arc, hybrid, butt welding process of SS400 structural steel. Welding parameters including laser power, welding current and speed were varied in order to obtain one-pass, full-penetration welds without defects. The conditions that resulted in optimal beads were identified. After welding, hardness measurements and microstructure observations were carried out in order to study weld properties. The mechanical properties of both the base material and welded specimen were compared based on the results of tensile strength measurements. The yield and tensile strengths were found to be similar

  16. Butt Weldability for SS400 Using Laser-Arc Hybrid Welding

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Do; Myoung, Gi Hoon; Park, Duck [Korea Maritime and Ocean Univ., Busan (Korea, Republic of); Myoung, Gi Hoon; Park, In Duck [Korea Institute of Machinery and Materials, Busan (Korea, Republic of)

    2016-07-15

    This study presents results of an experimental investigation of the laser-arc, hybrid, butt welding process of SS400 structural steel. Welding parameters including laser power, welding current and speed were varied in order to obtain one-pass, full-penetration welds without defects. The conditions that resulted in optimal beads were identified. After welding, hardness measurements and microstructure observations were carried out in order to study weld properties. The mechanical properties of both the base material and welded specimen were compared based on the results of tensile strength measurements. The yield and tensile strengths were found to be similar.

  17. Gas metal arc welding of butt joint with varying gap width based on neural networks

    DEFF Research Database (Denmark)

    Christensen, Kim Hardam; Sørensen, Torben

    2005-01-01

    penetration, when the gap width is varying during the welding process. The process modeling to facilitate the mapping from joint geometry and reference weld quality to significant welding parameters, has been based on a multi-layer feed-forward network. The Levenberg-Marquardt algorithm for non-linear least......This paper describes the application of the neural network technology for gas metal arc welding (GMAW) control. A system has been developed for modeling and online adjustment of welding parameters, appropriate to guarantee a certain degree of quality in the field of butt joint welding with full...

  18. TEM analysis of a friction stir-welded butt joint of Al-Si-Mg alloys

    International Nuclear Information System (INIS)

    Cabibbo, M.; Meccia, E.; Evangelista, E.

    2003-01-01

    The microstructure evolution of a joint of Al-Si-Mg alloys A6056-T4 and A6056-T6 has been characterized by transmission electron microscopy (TEM). Metallurgical investigations, hardness and mechanical tests were also performed to correlate the TEM investigations to the mechanical properties of the produced friction stir-welded butt joint. After friction stir-welding thermal treatment has been carried out at 530 deg. C followed by ageing at 160 deg. C (T6). The base material (T4) and the heat-treated one (T6) were put in comparison showing a remarkable ductility reduction of the joint after T6 treatment

  19. Human and animal sentinels for shared health risks

    Directory of Open Access Journals (Sweden)

    Peter Rabinowitz, MD, MPH

    2009-03-01

    Full Text Available The tracking of sentinel health events in humans in order to detect and manage disease risks facing a larger population is a well accepted technique applied to influenza, occupational conditions and emerging infectious diseases. Similarly, animal health professionals routinely track disease events in sentinel animal colonies and sentinel herds. The use of animals as sentinels for human health threats, or of humans as sentinels for animal disease risk, dates back at least to the era when coal miners brought caged canaries into mines to provide early warning of toxic gases. Yet the full potential of linking animal and human health information to provide warning of such ‘shared risks’ from environmental hazards has not been realised. Reasons appear to include the professional segregation of human and animal health communities, the separation of human and animal surveillance data and evidence gaps in the linkages between human and animal responses to environmental health hazards. The ‘One Health initiative’ and growing international collaboration in response to pandemic threats, coupled with development in the fields of informatics and genomics, hold promise for improved sentinel event coordination in order to detect and reduce environmental health threats shared between species.

  20. The geology of Pine and Crater Buttes: Two basaltic constructs on the far eastern Snake River Plain

    Science.gov (United States)

    Mazierski, Paul F.; King, John S.

    1987-01-01

    The emplacement history and petrochemical evolution of the volcanics associated with Pine Butte, Crater Butte, and other nearby vents are developed and described. Four major vents were identified in the study area and their associated eruptive products were mapped. All of the vents show a marked physical elongation or linear orientation coincident with the observed rift set. Planetary exploration has revealed the importance of volcanic processes in the genesis and modification of extraterrestrial surfaces. Interpretation of surface features has identified plains-type basaltic volcanism in various mare regions of the Moon and the volcanic provinces of Mars. Identification of these areas with features that appear analogous to those observed in the Pine Butte area suggests similar styles of eruption and mode of emplacement. Such terrestrial analogies serve as a method to interpret the evolution of volcanic planetary surfaces on the inner planets.

  1. Analytical model of stress field in submerged arc welding butt joint with thorough penetration

    Directory of Open Access Journals (Sweden)

    Winczek Jerzy

    2018-01-01

    Full Text Available Analytical model of temporary and residual stresses for butt welding with thorough penetration was described assuming planar section hypothesis and using integral equations of stress equilibrium of the bar and simple Hooke’s law. In solution the effect of phase transformations (structure changes and structural strains has been taken into account. Phase transformations during heating are limited by temperature values at the beginning and at the end of austenitic transformation, depending on chemical composition of steel while the progress of phase transformations during cooling is determined on the basis of TTT-welding diagram. Temperature values at the beginning and at the end of transformation are conditioned by the speed of heating. Kinetics of diffusional transformation is described basing on Johnson-Mehl-Avrami-Kolmogorov equation, while martensitic transformation, basing on Koistinen-Marburger equation. Stresses in elasto-plastic state are determined by iteration, using elastic solutions method with changeable longitudinal modulus of elasticity, conditioned by stress-strain curve. Computations of stress field have been conducted for one-side butt welded of two steel flats made from S235 steel. It has enabled a clear interpretation of influence of temperature field and phase transformation on stresses caused by welding using Submerged Arc Welding (SAW method.

  2. The microstructure of aluminum A5083 butt joint by friction stir welding

    International Nuclear Information System (INIS)

    Jasri, M. A. H. M.; Afendi, M.; Ismail, A.; Ishak, M.

    2015-01-01

    This study presents the microstructure of the aluminum A5083 butt joint surface after it has been joined by friction stir welding (FSW) process. The FSW process is a unique welding method because it will not change the chemical properties of the welded metals. In this study, MILKO 37 milling machine was modified to run FSW process on 4 mm plate of aluminum A5083 butt joint. For the experiment, variables of travel speed and tool rotational speed based on capability of machine were used to run FSW process. The concentrated heat from the tool to the aluminum plate changes the plate form from solid to plastic state. Two aluminum plates is merged to become one plate during plastic state and return to solid when concentrated heat is gradually further away. After that, the surface and cross section of the welded aluminum were investigated with a microscope by 400 x multiplication zoom. The welding defect in the FSW aluminum was identified. Then, the result was compared to the American Welding Society (AWS) FSW standard to decide whether the plate can be accepted or rejected

  3. A Precise Visual Method for Narrow Butt Detection in Specular Reflection Workpiece Welding

    Directory of Open Access Journals (Sweden)

    Jinle Zeng

    2016-09-01

    Full Text Available During the complex path workpiece welding, it is important to keep the welding torch aligned with the groove center using a visual seam detection method, so that the deviation between the torch and the groove can be corrected automatically. However, when detecting the narrow butt of a specular reflection workpiece, the existing methods may fail because of the extremely small groove width and the poor imaging quality. This paper proposes a novel detection method to solve these issues. We design a uniform surface light source to get high signal-to-noise ratio images against the specular reflection effect, and a double-line laser light source is used to obtain the workpiece surface equation relative to the torch. Two light sources are switched on alternately and the camera is synchronized to capture images when each light is on; then the position and pose between the torch and the groove can be obtained nearly at the same time. Experimental results show that our method can detect the groove effectively and efficiently during the welding process. The image resolution is 12.5 μm and the processing time is less than 10 ms per frame. This indicates our method can be applied to real-time narrow butt detection during high-speed welding process.

  4. Primary water stress corrosion cracking resistance of alloy 690 heat affected zones of butt welds

    International Nuclear Information System (INIS)

    Fournier, L.; Calonne, O.; Toloczko, M.B.; Bruemmer, S.M.; Massoud, J.P.; Lemaire, E.; Gerard, R.; Somville, F.; Richnau, A.; Lagerstrom, J.

    2015-01-01

    A wide V-groove butt weld was fabricated from Alloy 690 plates using Alloy 152 filler material, maximum allowable heat input, and very stiff strong-backs. Alloy 690 heat affected zones (HAZ) was characterized in terms of microstructure and plastic strains induced by weld shrinkage. Crack initiation tests were carried out in pure hydrogenated steam at 400 C. degrees for 4000 h. Crack growth rate tests were performed in simulated PWR primary water at a temperature of 360 C. degrees. A maximum plastic strain around 5% was measured in the vicinity of the fusion line, which decreased almost linearly with the distance from the fusion line. Crack initiation tests on Alloy 690 HAZ specimens as well as on 30% cold-rolled Alloy 690 specimens were performed in pure hydrogenated steam at 400 C. degrees (partial pressure of hydrogen = 0.7 bar) for a total of 4000 h using cylindrical notched tensile specimens, reverse U-bends and flat micro-tensile specimens. No crack initiation was detected. Stress corrosion propagation rates revealed extremely low SCC (Stress Corrosion Cracking) growth rates both in the base metal and in the HAZ region whose magnitudes are of no engineering significance. Overall, the results indicated limited plastic strain induced by weld shrinkage in butt weld HAZ, and to no particular susceptibility of primary water stress corrosion cracking. (authors)

  5. The microstructure of aluminum A5083 butt joint by friction stir welding

    Energy Technology Data Exchange (ETDEWEB)

    Jasri, M. A. H. M.; Afendi, M. [School of Mechatronic Engineering, Universiti Malaysia Perlis, Pauh, 02600, Arau, Perlis (Malaysia); Ismail, A. [UniKL MIMET, JalanPantaiRemis, 32200, Lumut, Perak (Malaysia); Ishak, M. [Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 02600, Pekan, Pahang (Malaysia)

    2015-05-15

    This study presents the microstructure of the aluminum A5083 butt joint surface after it has been joined by friction stir welding (FSW) process. The FSW process is a unique welding method because it will not change the chemical properties of the welded metals. In this study, MILKO 37 milling machine was modified to run FSW process on 4 mm plate of aluminum A5083 butt joint. For the experiment, variables of travel speed and tool rotational speed based on capability of machine were used to run FSW process. The concentrated heat from the tool to the aluminum plate changes the plate form from solid to plastic state. Two aluminum plates is merged to become one plate during plastic state and return to solid when concentrated heat is gradually further away. After that, the surface and cross section of the welded aluminum were investigated with a microscope by 400 x multiplication zoom. The welding defect in the FSW aluminum was identified. Then, the result was compared to the American Welding Society (AWS) FSW standard to decide whether the plate can be accepted or rejected.

  6. Study on Tensile Fatigue Behavior of Thermal Butt Fusion in Safety Class III High-Density Polyethylene Buried Piping in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Jong Sung; Lee, Young Ju; Oh, Young Jin

    2015-01-01

    High-density polyethylene (HDPE) piping, which has recently been applied to safety class III piping in nuclear power plants, can be butt-joined through the thermal fusion process, which heats two fused surfaces and then subject to axial pressure. The thermal fusion process generates bead shapes on the butt fusion. The stress concentrations caused by the bead shapes may reduce the fatigue lifetime. Thus, investigating the effect of the thermal butt fusion beads on fatigue behavior is necessary. This study examined the fatigue behavior of thermal butt fusion via a tensile fatigue test under stress-controlled conditions using finite element elastic stress analysis. Based on the results, the presence of thermal butt fusion beads was confirmed to reduce the fatigue lifetime in the low-cycle fatigue region while having a negligible effect in the medium- and high-cycle fatigue regions

  7. Study on Tensile Fatigue Behavior of Thermal Butt Fusion in Safety Class III High-Density Polyethylene Buried Piping in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Sung; Lee, Young Ju [Sunchon National University, Suncheon (Korea, Republic of); Oh, Young Jin [KEPCO E and C, Yongin (Korea, Republic of)

    2015-01-15

    High-density polyethylene (HDPE) piping, which has recently been applied to safety class III piping in nuclear power plants, can be butt-joined through the thermal fusion process, which heats two fused surfaces and then subject to axial pressure. The thermal fusion process generates bead shapes on the butt fusion. The stress concentrations caused by the bead shapes may reduce the fatigue lifetime. Thus, investigating the effect of the thermal butt fusion beads on fatigue behavior is necessary. This study examined the fatigue behavior of thermal butt fusion via a tensile fatigue test under stress-controlled conditions using finite element elastic stress analysis. Based on the results, the presence of thermal butt fusion beads was confirmed to reduce the fatigue lifetime in the low-cycle fatigue region while having a negligible effect in the medium- and high-cycle fatigue regions.

  8. The Sentinel-4 UVN focal plane assemblies

    Science.gov (United States)

    Hinger, Jürgen; Hohn, Rüdiger; Gebhardt, Eyk; Reichardt, Jörg

    2017-09-01

    The Sentinel-4 UVN Instrument is a dispersive imaging spectrometer covering the UV-VIS and the NIR wavelength. It is developed and built under an ESA contract by an industrial consortium led by Airbus Defence and Space. It will be accommodated on board of the MTG-S (Meteosat Third Generation - Sounder) satellite that will be placed in a geostationary orbit over Europe sampling data for generating two-dimensional maps of a number of atmospheric trace gases. The incoming light is dispersed by reflective gratings and detected by the two (UVVIS and NIR) CCDs mounted inside the focal plane assemblies. Both CCD detectors acquire spectral channels and spatial sampling in two orthogonal directions and will be operated at about 215 K mainly to minimize random telegraph signal effects and to reduce dark current. Stringent detector temperature as well as alignment stability requirements of less than +/-0.1 K per day respectively of less than 2 micrometers/2 arcseconds from ground to orbit are driving the FPA thermo-mechanical design. A specific FPA design feature is the redundant LED-calibration system for bad pixel detection as well as pixel gain and linearity monitoring. This paper reports on the design and qualification of the Focal Plane Assemblies with emphasis on thermo-mechanical as well as alignment stability verification.

  9. Hybrid tracers for sentinel node biopsy

    International Nuclear Information System (INIS)

    Van Den Berg, N. S.; Kleinjan, G. I.; Valdés-Olmos, R. A.; Buckle, T.; Van Leeuwen, F. I.; Klop, W. M.; Horenblas, S.; Van Der Poel, H. G.

    2014-01-01

    Conventional sentinel node (SN) mapping is performed by injection of a radiocolloid followed by lymphoscintigraphy to identify the number and location of the primary tumor draining lymph node(s), the so-called SN(s). Over the last decade research has focused on the introduction of new imaging agents that can further aid (surgical) SN identification. Different tracers for SN mapping, with varying sizes and isotopes have been reported, most of which have proven their value in a clinical setting. A major challenge lies in transferring this diagnostic information obtained at the nuclear medicine department to the operating theatre thereby providing the surgeon with (image) guidance. Conventionally, an intraoperative injection of vital blue dye or a fluorescence dye is given to allow intraoperative optical SN identification. However, for some indications, the radiotracer-based approach remains crucial. More recently, hybrid tracers, that contain both a radioactive and fluorescent label, were introduced to allow for direct integration of pre- and intraoperative guidance technologies. Their potential is especially high when they are used in combination with new surgical imaging modalities and navigation tools. Next to a description of the known tracers for SN mapping, this review discusses the application of hybrid tracers during SN biopsy and how the introduction of these new techniques can further aid in translation of nuclear medicine information into the operating theatre.

  10. Satellites as Sentinels for Environment & Health

    Science.gov (United States)

    Maynard, Nancy G.

    2002-01-01

    Satellites as Sentinels for Environment & Health Remotely-sensed data and observations are providing powerful new tools for addressing human and ecosystem health by enabling improved understanding of the relationships and linkages between health-related environmental parameters and society as well as techniques for early warning of potential health problems. NASA Office of Earth Science Applications Program has established a new initiative to utilize its data, expertise, and observations of the Earth for public health applications. In this initiative, lead by Goddard Space Flight Center, remote sensing, geographic information systems, improved computational capabilities, and interdisciplinary research between the Earth and health science communities are being combined in rich collaborative efforts resulting in more rapid problem-solving, early warning, and prevention in global health issues. This presentation provides a number of recent examples of applications of advanced remote sensing and other technologies to health.and security issues related to the following: infectious and vector-borne diseases; urban, regional and global air pollution; African and Asian airborne dust; heat stress; UV radiation; water-borne disease; extreme weather; contaminant pathways (ocean, atmosphere, ice)

  11. Age of the middle Palaeolithic site of La Butte d'Arvigny (Moissy-Cramayel, Seine-et-Marne); Datation du site paleolithique moyen de la Butte d'Arvigny (Moissy-Cramayel, Seine-et-Marne)

    Energy Technology Data Exchange (ETDEWEB)

    Laurent, M. [Ecole Nationale Superieure de Chimie, Lab. de Travaux Pratiques de Genie Chimique, 75 - Paris (France); Laurent, M.; Bahain, J.J.; Voinchet, P.; Ricard, J.L. [Lab. de Prehistoire du Museum National d' Histoire Naturelle, Institut de Paleontologie Humaine, UMR 6569 du CNRS, 75 - Paris (France); Rousseau, L. [Amiens Univ., Lab. de Sedimentologie et de Geochimie, 80 (France)

    2000-04-01

    The middle Palaeolithic site of La Butte d'Arvigny, close to Melun, was dated using electron spin resonance (ESR) method on burn flint. Five analysed burnt flints give a mean age of 90 000 years, which ascribes Arvigny to the Mousterian laminar complex of northern France. (authors)

  12. Intraflow structures of the Cohassett flow at east Sentinel Gap and Sentinel Mountain

    International Nuclear Information System (INIS)

    Cross, R.W.; Fairchild, K.R.

    1988-04-01

    This report presents the results of outcrop intraflow structure studies in the Cohassett flow at east Sentinel Gap and Sentinel Mountain on the northwestern margin of the Pasco Basin. This study is the first of several Cohassett outcrop studies. The studies will aid in characterizing intraflow structures of the Cohassett flow to support design and construction and to aid in assessing the performance of a possible high-level nuclear waste repository in the subsurface of the reference repository location at the Hanford Site. A total of twenty-four intraflow structure sections of the Cohassett flow were measured at two, adjacent study areas. The measured sections provide positions, thicknesses, and descriptions of every intraflow structure encountered within the Cohassett flow. Graphic logs of each section display the sequence of intraflow structures per measured section. Correlation diagrams depict interpretations of the lateral continuity and thickness variations of each intraflow structure across the total of 6 km of the two study areas. Consistencies of intraflow structures are observed across the study area. The Cohassett flow interior in outcrop is consistently thick and never thins to less than 51 m. The flow interior is interpreted as laterally continuous across the study areas, and no features are observed to interrupt its horizontal extent. Based on the field observations, there is interpreted lateral continuity of packets of intraflow structures within the flow interior. 20 refs., 24 figs

  13. Synergy between Sentinel-1 radar time series and Sentinel-2 optical for the mapping of restored areas in Danube delta

    Science.gov (United States)

    Niculescu, Simona; Lardeux, Cédric; Hanganu, Jenica

    2018-05-01

    Wetlands are important and valuable ecosystems, yet, since 1900, more than 50 % of wetlands have been lost worldwide. An example of altered and partially restored coastal wetlands is the Danube Delta in Romania. Over time, human intervention has manifested itself in more than a quarter of the entire Danube surface. This intervention was brutal and has rendered ecosystem restoration very difficult. Studies for the rehabilitation / re-vegetation were started immediately after the Danube Delta was declared as a Biosphere Reservation in 1990. Remote sensing offers accurate methods for detecting and mapping change in restored wetlands. Vegetation change detection is a powerful indicator of restoration success. The restoration projects use vegetative cover as an important indicator of restoration success. To follow the evolution of the vegetation cover of the restored areas, satellite images radar and optical of last generation have been used, such as Sentinel-1 and Sentinel-2. Indeed the sensor sensitivity to the landscape depends on the wavelength what- ever radar or optical data and their polarization for radar data. Combining this kind of data is particularly relevant for the classification of wetland vegetation, which are associated with the density and size of the vegetation. In addition, the high temporal acquisition frequency of Sentinel-1 which are not sensitive to cloud cover al- low to use temporal signature of the different land cover. Thus we analyse the polarimetric and temporal signature of Sentinel-1 data in order to better understand the signature of the different study classes. In a second phase, we performed classifications based on the Random Forest supervised classification algorithm involving the entire Sentinel-1 time series, then starting from a Sentinel-2 collection and finally involving combinations of Sentinel-1 and -2 data.

  14. Marine mammals as sentinel species for oceans and human health.

    Science.gov (United States)

    Bossart, G D

    2011-05-01

    The long-term consequences of climate change and potential environmental degradation are likely to include aspects of disease emergence in marine plants and animals. In turn, these emerging diseases may have epizootic potential, zoonotic implications, and a complex pathogenesis involving other cofactors such as anthropogenic contaminant burden, genetics, and immunologic dysfunction. The concept of marine sentinel organisms provides one approach to evaluating aquatic ecosystem health. Such sentinels are barometers for current or potential negative impacts on individual- and population-level animal health. In turn, using marine sentinels permits better characterization and management of impacts that ultimately affect animal and human health associated with the oceans. Marine mammals are prime sentinel species because many species have long life spans, are long-term coastal residents, feed at a high trophic level, and have unique fat stores that can serve as depots for anthropogenic toxins. Marine mammals may be exposed to environmental stressors such as chemical pollutants, harmful algal biotoxins, and emerging or resurging pathogens. Since many marine mammal species share the coastal environment with humans and consume the same food, they also may serve as effective sentinels for public health problems. Finally, marine mammals are charismatic megafauna that typically stimulate an exaggerated human behavioral response and are thus more likely to be observed.

  15. Lymphatic drainage and sentinel node location in breast cancer

    International Nuclear Information System (INIS)

    Uren, R.F.; Howman-Giles, R.B.; Roberts, J.; Renwick, S.; Gillett, D.; Neische, F.; Ramsay-Stewart, G.

    1999-01-01

    Full text: Mammary lymphoscintigraphy using small volume (0.1-0.2 ml) peritumoral injections of 99 Tc m -antimony sulphide colloid provided a map of the lymph drainage of a breast cancer to its draining sentinel lymph nodes in 92 of 102 patients (over 90%). Non-migration of tracer is reduced by post-injection massage for 5 min but may occur especially if the lymphatics are blocked by metastases. Drainage included the axilla in 92%, internal mammary nodes in 43%, supraclavicular nodes in 12% and intramammary interval nodes in 10% of patients. One patient drained to an interpectoral node. Drainage across the centre-line of the breast occurred in 46% of patients but direct drainage to the contralateral side of the patient was not seen. Lymphatic drainage occurred to 1 node field in 52 patients, 2 node fields in 34 patients and 3 node fields in 6 patients, so that 43% of patients had multiple draining node fields. Drainage to non-axillary sites occurred in 51% of patients. In conclusion, mammary lymphoscintigraphy accurately maps sentinel node location in breast cancer. Approximately half of the patients will have sentinel nodes outside the axilla. To achieve complete lymph node staging in patients with breast cancer, it is logical to biopsy these non-axillary sentinel nodes as well as the sentinel nodes in the axilla. Failure to do so will potentially understage the node status in 50% of patients

  16. The Sentinel-1 Mission: New Opportunities for Ice Sheet Observations

    Directory of Open Access Journals (Sweden)

    Thomas Nagler

    2015-07-01

    Full Text Available The Sentinel satellite constellation series, developed by the European Space Agency, represents the dedicated space component of the European Copernicus program, committed to long-term operational services in a wide range of application domains. Here, we address the potential of the Sentinel-1 mission for mapping and monitoring the surface velocity of glaciers and ice sheets. We present an ice velocity map of Greenland, derived from synthetic aperture radar (SAR data acquired in winter 2015 by Sentinel-1A, the first satellite of the Copernicus program in orbit. The map is assembled from about 900 SAR scenes acquired in Interferometric Wide swath (IW mode, applying the offset tracking technique. We discuss special features of IW mode data, describe the procedures for producing ice velocity maps, and assess the uncertainty of the ice motion product. We compare the Sentinel-1 ice motion product with velocity maps derived from high resolution SAR data of the TerraSAR-X mission and from PALSAR data. Beyond supporting operational services, the Sentinel-1 mission offers enhanced capabilities for comprehensive and long-term observation of key climate variables, such as the motion of ice masses.

  17. Sentinel lymph node biopsy in local recurrence of cutaneous melanoma

    International Nuclear Information System (INIS)

    Junqueira, G. Jr.; Bodanese, B.; Boff, M.F.; Espindola, M.B.; Haack, R.L.; Frigeri, C.D.L.

    2004-01-01

    Full text: Locally recurrent disease in patients with melanoma is usually defined as cutaneous or subcutaneous arising within 5 cm of the primary site after complete excision of the primary lesion. It may represent residual disease not excised with the primary tumor or the outgrowth of the satellite lesions, which are common with melanoma. Lymphatic mapping and sentinel lymph node (SLN) biopsy is highly accurate in staging nodal basins at risk of regional metastases in primary melanoma patients and identifies those who may benefit from earlier lymphadenectomy. Our purpose was to evaluate the efficacy of sentinel lymph node mapping and biopsy in local recurrence of cutaneous melanoma when the primary lesion was less than 1.0mm thick. Three patients with local recurrence of cutaneous melanoma underwent sentinel lymph node mapping and biopsy. All patients underwent preoperative lymphoscintigraphy to identify the lymphatic basin and the site of the sentinel node. All patients subsequently underwent intra-operative lymphatic mapping and selective lymph node biopsy with vital blue dye and hand-held gamma probe. Excised SLN were analysed by conventional histological staining (H and E) and immunohistochemical staining. In all patients the lymphatic mapping and sentinel lymph node biopsy was successful. The SLN biopsy was negative in two patients and positive in one who underwent therapeutic lymph node dissection. Our results indicate that the SLN mapping and biopsy is also possible in patients having local recurrence of cutaneous melanoma. Although long-term results are not available, early results are promising. (author)

  18. 76 FR 21331 - Certain Carbon Steel Butt-Weld Pipe Fittings From Brazil, Japan, Taiwan, Thailand, and the People...

    Science.gov (United States)

    2011-04-15

    ... the People's Republic of China: Continuation of Antidumping Duty Orders AGENCY: Import Administration... butt-weld pipe fittings from Brazil, Japan, Taiwan, Thailand, and the People's Republic of China (PRC), pursuant to section 751(c) of the Tariff Act of 1930, as amended (the Act). See Initiation of Five-Year...

  19. Butt-joint integration of active optical components based on InP/AlInGaAsP alloys

    DEFF Research Database (Denmark)

    Kulkova, Irina; Kuznetsova, Nadezda; Semenova, Elizaveta

    2014-01-01

    We demonstrate all-active planar high quality butt-joint (BJ) integration of a QW Semiconductor Optical Amplifier (SOA) and MQW Electro-Absorption Modulator (EAM) based on an InP/AlInGaAsP platform. The degradation of the optical properties in the vicinity of ~1 μm to the BJ interface was determi...

  20. TIG-dressing of High Strength Steel Butt Welded Connections. Part 1 : Weld Toe Geometry and Local Hardness

    NARCIS (Netherlands)

    Van Es, S.H.J.; Kolstein, M.H.; Pijpers, R.J.M.; Bijlaard, F.S.K.

    2014-01-01

    This paper presents the results of extensive measurements on weld toe geometry of as-welded and TIG-dressed butt welded connections in high strength steels S460, S690 and very high strength steels S890 and S1100. Descriptions of the measurement techniques and data analysis are presented. Four weld

  1. TIG-dressing of high strength steel butt welded connections - Part 1: weld toe geometry and local hardness

    NARCIS (Netherlands)

    Es, S.H.J. van; Kolstein, M.H.; Pijpers, R.J.M.; Bijlaard, F.S.K.

    2013-01-01

    This paper presents the results of extensive measurements on weld toe geometry of as-welded and TIG-dressed butt welded connections in high strength steels S460, S690 and very high strength steels S890 and S1100. Descriptions of the measurement techniques and data analysis are presented. Four weld

  2. 77 FR 18266 - Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines; Revised...

    Science.gov (United States)

    2012-03-27

    ... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 731-TA-865-867 (Second Review)] Stainless Steel Butt-Weld Pipe Fittings From Italy, Malaysia, and the Philippines; Revised Schedule for the Subject Reviews AGENCY: United States International Trade Commission. ACTION: Notice. DATES: Effective Date: March...

  3. 75 FR 430 - Notice of Intent To Prepare an Environmental Impact Statement for the Sigurd-Red Butte...

    Science.gov (United States)

    2010-01-05

    ...; UTU-83067] Notice of Intent To Prepare an Environmental Impact Statement for the Sigurd-Red Butte...) Cedar City Field Office, Cedar City, Utah, intends to prepare an Environmental Impact Statement (EIS... Fishlake National Forests), State of Utah, Millard County, Sevier County, Beaver County, Utah Division of...

  4. 76 FR 30962 - Notice of Availability of Draft Environmental Impact Statement for the Sigurd to Red Butte No. 2...

    Science.gov (United States)

    2011-05-27

    ...; UTU-83067] Notice of Availability of Draft Environmental Impact Statement for the Sigurd to Red Butte..., as amended, the Bureau of Land Management (BLM) has prepared a Draft Environmental Impact Statement... Service; State of Utah; Millard, Sevier, Beaver, Iron, and Washington counties, Utah; and the cities of St...

  5. 76 FR 5205 - Carbon Steel Butt-Weld Pipe Fittings from Brazil, China, Japan, Taiwan, and Thailand

    Science.gov (United States)

    2011-01-28

    ...)] Carbon Steel Butt-Weld Pipe Fittings from Brazil, China, Japan, Taiwan, and Thailand AGENCY: United... Thailand. SUMMARY: The Commission hereby gives notice of the scheduling of expedited reviews pursuant to..., Taiwan, and Thailand would be likely to lead to continuation or recurrence of material injury within a...

  6. 75 FR 60814 - Carbon Steel Butt-Weld Pipe Fittings From Brazil, China, Japan, Taiwan, and Thailand

    Science.gov (United States)

    2010-10-01

    ...)] Carbon Steel Butt-Weld Pipe Fittings From Brazil, China, Japan, Taiwan, and Thailand AGENCY: United... Thailand. SUMMARY: The Commission hereby gives notice that it has instituted reviews pursuant to section... Thailand would be likely to lead to continuation or recurrence of material injury. Pursuant to section 751...

  7. Age of the middle Palaeolithic site of La Butte d'Arvigny (Moissy-Cramayel, Seine-et-Marne)

    International Nuclear Information System (INIS)

    Laurent, M.; Laurent, M.; Bahain, J.J.; Voinchet, P.; Ricard, J.L.; Rousseau, L.

    2000-01-01

    The middle Palaeolithic site of La Butte d'Arvigny, close to Melun, was dated using electron spin resonance (ESR) method on burn flint. Five analysed burnt flints give a mean age of 90 000 years, which ascribes Arvigny to the Mousterian laminar complex of northern France. (authors)

  8. 76 FR 19788 - Carbon Steel Butt-Weld Pipe Fittings From Brazil, China, Japan, Taiwan, and Thailand

    Science.gov (United States)

    2011-04-08

    ...)] Carbon Steel Butt-Weld Pipe Fittings From Brazil, China, Japan, Taiwan, and Thailand Determinations On... fittings from Brazil, China, Japan, Taiwan, and Thailand would be likely to lead to continuation or recurrence of material injury to an industry in the United States within a reasonably foreseeable time. \\1...

  9. [Intraoperative detection of the sentinel lymph nodes in lung cancer].

    Science.gov (United States)

    Akopov, A L; Papayan, G V; Chistyakov, I V

    2015-01-01

    An analysis of the scientific data was made. It was used the literature devoted to the intraoperative visualization of the sentinel lymph nodes in patients with lung cancer. Correct detection of such lymph nodes with following pathologic investigation allowed limiting the volume of lympho-dissection in a number of patients. There is the possibility of maximal in-depth study of the sentinel lymph nodes by purposeful application of most sensible pathologic and molecular methods for detection their micrometastatic lesions. At the same time the treatment strategy and prognosis could be determined. The authors present the results of an application of dye techniques, radioactive preparation and fluorescence imaging for sentinel lymph node detection. Advantages and disadvantages of the methods are shown in the article. There are validated the prospects of technical development, study of information value of new applications and the most perspective method of fluorescence indocyanine green visualization by lymph outflow.

  10. Getting ready for the arrival of Sentinel data

    Science.gov (United States)

    Aschbacher, Josef; Milagro Perez, Maria Pilar

    2013-04-01

    The European Union (EU) and the European Space Agency (ESA) have developed the Global Monitoring for Environment and Security (GMES), being renamed to Copernicus, programme as Europe's answer to the vital need for joined-up data about our climate, environment and security. Through a unique combination of satellite, atmospheric and Earth-based monitoring systems, the initiative will provide new insight into the state of the land, sea and air, providing policymakers, scientists, businesses and the public with accurate and timely information. GMES capabilities include monitoring and forecasting of climatic change, flood risks, soil and coastal erosion, crop and fish resources, air pollution, greenhouse gases, iceberg distribution and snow cover, among others. To accomplish this, GMES has been divided into three main components: Space, In-situ and Services. The Space Component, led by ESA, comprises five types of new dedicated satellites called Sentinels. These missions carry a range of technologies, such as radar and multi-spectral imaging instruments for land, ocean and atmospheric monitoring. While the Sentinel satellites are currently being developed by ESA specifically to meet the needs of GMES, the Contributing Missions, operated by national agencies or commercial entities, are already providing a wealth of data for GMES services, and will continue to deliver complementary data after the Sentinels are in orbit. An integrated Ground Segment ensures access to Sentinels and Contributing Missions data. Access to Sentinel data is governed by the Sentinel data policy, which is part of a wider GMES data and information access policy. The Sentinel data policy envisages free and open access, subject to restrictions only if security or other European interests need to be preserved. As regards the Contributing Missions, the data policy of the mission owners will be respected for the purpose of providing data to GMES service users. The first in the fleet of dedicated

  11. Atmospheric Phase Delay in Sentinel SAR Interferometry

    Science.gov (United States)

    Krishnakumar, V.; Monserrat, O.; Crosetto, M.; Crippa, B.

    2018-04-01

    The repeat-pass Synthetic Aperture Radio Detection and Ranging (RADAR) Interferometry (InSAR) has been a widely used geodetic technique for observing the Earth's surface, especially for mapping the Earth's topography and deformations. However, InSAR measurements are prone to atmospheric errors. RADAR waves traverse the Earth's atmosphere twice and experience a delay due to atmospheric refraction. The two major layers of the atmosphere (troposphere and ionosphere) are mainly responsible for this delay in the propagating RADAR wave. Previous studies have shown that water vapour and clouds present in the troposphere and the Total Electron Content (TEC) of the ionosphere are responsible for the additional path delay in the RADAR wave. The tropospheric refractivity is mainly dependent on pressure, temperature and partial pressure of water vapour. The tropospheric refractivity leads to an increase in the observed range. These induced propagation delays affect the quality of phase measurement and introduce errors in the topography and deformation fields. The effect of this delay was studied on a differential interferogram (DInSAR). To calculate the amount of tropospheric delay occurred, the meteorological data collected from the Spanish Agencia Estatal de Meteorología (AEMET) and MODIS were used. The interferograms generated from Sentinel-1 carrying C-band Synthetic Aperture RADAR Single Look Complex (SLC) images acquired on the study area are used. The study area consists of different types of scatterers exhibiting different coherence. The existing Saastamoinen model was used to perform a quantitative evaluation of the phase changes caused by pressure, temperature and humidity of the troposphere during the study. Unless the phase values due to atmospheric disturbances are not corrected, it is difficult to obtain accurate measurements. Thus, the atmospheric error correction is essential for all practical applications of DInSAR to avoid inaccurate height and deformation

  12. ATMOSPHERIC PHASE DELAY IN SENTINEL SAR INTERFEROMETRY

    Directory of Open Access Journals (Sweden)

    V. Krishnakumar

    2018-04-01

    Full Text Available The repeat-pass Synthetic Aperture Radio Detection and Ranging (RADAR Interferometry (InSAR has been a widely used geodetic technique for observing the Earth’s surface, especially for mapping the Earth’s topography and deformations. However, InSAR measurements are prone to atmospheric errors. RADAR waves traverse the Earth’s atmosphere twice and experience a delay due to atmospheric refraction. The two major layers of the atmosphere (troposphere and ionosphere are mainly responsible for this delay in the propagating RADAR wave. Previous studies have shown that water vapour and clouds present in the troposphere and the Total Electron Content (TEC of the ionosphere are responsible for the additional path delay in the RADAR wave. The tropospheric refractivity is mainly dependent on pressure, temperature and partial pressure of water vapour. The tropospheric refractivity leads to an increase in the observed range. These induced propagation delays affect the quality of phase measurement and introduce errors in the topography and deformation fields. The effect of this delay was studied on a differential interferogram (DInSAR. To calculate the amount of tropospheric delay occurred, the meteorological data collected from the Spanish Agencia Estatal de Meteorología (AEMET and MODIS were used. The interferograms generated from Sentinel-1 carrying C-band Synthetic Aperture RADAR Single Look Complex (SLC images acquired on the study area are used. The study area consists of different types of scatterers exhibiting different coherence. The existing Saastamoinen model was used to perform a quantitative evaluation of the phase changes caused by pressure, temperature and humidity of the troposphere during the study. Unless the phase values due to atmospheric disturbances are not corrected, it is difficult to obtain accurate measurements. Thus, the atmospheric error correction is essential for all practical applications of DInSAR to avoid inaccurate

  13. [Identification of sentinel events in primary care].

    Science.gov (United States)

    Olivera Cañadas, G; Cañada Dorado, A; Drake Canela, M; Fernández-Martínez, B; Ordóñez León, G; Cimas Ballesteros, M

    To identify and describe a list of sentinel events (SEs) for Primary Care (PC). A structured experts' consensus was obtained by using two online questionnaires. The participants were selected because of their expertise in PC and patient safety. The first questionnaire assessed the suitability of the hospital SEs established in the National Quality Forum 2006 for use in PC via responses of "yes", "no", or "yes but with modification". In the latter case, a re-wording of the SE was requested. Additionally, inclusion of new SEs was also allowed. The second questionnaire included those SEs with positive responses ("yes", "yes with modification"), so that the experts could choose between the original and alternative drafts, and evaluate the newly described SEs. The questionnaires were completed by 44 out of a total of the 47 experts asked to participate, and a total of 17 SEs were identified as suitable for PC. For the first questionnaire, 12 of the 28 hospital SEs were considered adaptable to PC, of which 11 were re-drafts. Thirty-seven experts proposed new SEs. These mainly concerned problems with medication and vaccines, delay, or lack of assistance, diagnostic delays, and problems with diagnostic tests, and were finally summarised in 5 SEs. In the second questionnaire, ≥65% of the experts chose the alternative wording against the original cases for the 11 SEs suitable for PC. The 5 newly included SEs were considered adequate with a positive response of 70-85%. Having a list of SEs available in PC will help to improve the management of health care risks. Copyright © 2017 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Sentinel lymph node concept in oral cancer

    International Nuclear Information System (INIS)

    Hasegawa, Shogo; Omura, Ken; Harada, Hiroyuki; Shimamoto, Hiroaki; Yoshida, Yoshihiko; Uekusa, Masaru; Togawa, Takashi

    2005-01-01

    The cervical lymph node (CLN) status is one of the most important prognostic factors in oral cancer. However, the main method of addressing the CLN depends on diagnostic imaging. Sentinel lymph node (SN) biopsy combined with lymphoscintigraphy may be a minimally invasive technique that samples first-echelon lymph node to predict the need for neck dissection. Focused analysis of the SN is highly accurate in identifying metastases. In this study, we investigate the possibility of identifying the SN in oral cancer and the detection of metastases in SN by HE stain, cytokeratin IHC and cytokeratin 17 reverse transcription polymerase chain reaction (RT-PCR). Twenty-four consecutive patients who had clinically negative CLN underwent SN biopsy, followed by elective neck dissection. SNs were detected by means of mapping with isotope labeling 99m Tc-phytate. All lymph nodes were examined by conventional HE staining for evaluating metastasis. In addition, each SN was cut into multiple sections for cytokeratin IHC staining and for RT-PCR for cytokeratin 17. SNs were identified in 24 (100%) of 24 patients by lymphoscintigraphy and gamma probe. One to seven SNs were identified in each patient. Both HE and immunohistochemical staining of SN identified metastasis in 7 patients (29.2%), and the expression of cytokeratin 17 by RT-PCR of SN was positive in 8 patients (34.8%). No metastases were identified using HE, cytokeratin IHC staining in non-SNs. Neck failure has not developed in 23 (95.8%) of 24 patients. The results strongly suggest the usefulness of the SN concept in oral cancer and for better assessing the status of the CLN. (author)

  15. Avian wildlife as sentinels of ecosystem health.

    Science.gov (United States)

    Smits, Judit E G; Fernie, Kimberly J

    2013-05-01

    Birds have been widely used as sentinels of ecosystem health reflecting changes in habitat quality, increased incidence of disease, and exposure to and effects of chemical contaminants. Numerous studies addressing these issues focus on the breeding period, since hormonal, behavioural, reproductive, and developmental aspects of the health can be observed over a relatively short time-span. Many body systems within individuals are tightly integrated and interdependent, and can be affected by contaminant chemicals, disease, and habitat changes in complex ways. Animals higher in the food web will reflect cumulative effects of multiple stressors. Such features make birds ideal indicators for assessing environmental health in areas of environmental concern. Five case studies are presented, highlighting the use of different species which have provided insight into ecosystem sustainability, including (i) the consequences of anthropogenic disturbances of sagebrush habitat on the greater northern sage grouse Centrocercus urophasianus; (ii) the high prevalence of disease in very specific passerine species in the Canary Islands closely paralleling deterioration of formerly productive desert habitat and ensuing interspecific stressors; (iii) fractures, abnormal bone structure, and associated biochemical aberrations in nestling storks exposed to acidic tailings mud from a dyke rupture at an iron pyrite mine near Sevilla, Spain; (iv) newly presented data demonstrating biochemical changes in nestling peregrine falcons Falco peregrinus and associations with exposure to major chemical classes in the Great Lakes Basin of Canada; and (v) the variability in responses of tree swallows Tachycineta bicolor to contaminants, biological and meteorological challenges when breeding in the Athabasca oil sands. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Episodic Holocene eruption of the Salton Buttes rhyolites, California, from paleomagnetic, U-Th, and Ar/Ar dating

    Science.gov (United States)

    Wright, Heather M.; Vazquez, Jorge A.; Champion, Duane E.; Calvert, Andrew T.; Mangan, Margaret T.; Stelten, Mark E.; Cooper, Kari M.; Herzig, Charles; Schriener Jr., Alexander

    2015-01-01

    In the Salton Trough, CA, five rhyolite domes form the Salton Buttes: Mullet Island, Obsidian Butte, Rock Hill, North and South Red Hill, from oldest to youngest. Results presented here include 40Ar/39Ar anorthoclase ages, 238U-230Th zircon crystallization ages, and comparison of remanent paleomagnetic directions with the secular variation curve, which indicate that all domes are Holocene. 238U-230Th zircon crystallization ages are more precise than but within uncertainty of 40Ar/39Ar anorthoclase ages, suggesting that zircon crystallization proceeded until shortly before eruption in all cases except one. Remanent paleomagnetic directions require three eruption periods: (1) Mullet Island, (2) Obsidian Butte, and (3) Rock Hill, North Red Hill, and South Red Hill. Borehole cuttings logs document up to two shallow tephra layers. North and South Red Hills likely erupted within 100 years of each other, with a combined 238U-230Th zircon isochron age of: 2.83 ± 0.60 ka (2 sigma); paleomagnetic evidence suggests this age predates eruption by hundreds of years (1800 cal BP). Rock Hill erupted closely in time to these eruptions. The Obsidian Butte 238U-230Th isochron age (2.86 ± 0.96 ka) is nearly identical to the combined Red Hill age, but its Virtual Geomagnetic Pole position suggests a slightly older age. The age of aphyric Mullet Island dome is the least well constrained: zircon crystals are resorbed and the paleomagnetic direction is most distinct; possible Mullet Island ages include ca. 2300, 5900, 6900, and 7700 cal BP. Our results constrain the duration of Salton Buttes volcanism to between ca. 5900 and 500 years.

  17. Sentinel Asia step 2 utilization for disaster management in Malaysia

    International Nuclear Information System (INIS)

    Moslin, S I; Wahap, N A; Han, O W

    2014-01-01

    With the installation of Wideband InterNetworking engineering test and Demonstration Satellite (WINDS) communication system in the National Space Centre, Banting; officially Malaysia is one of the twelve Sentinel Asia Step2 System Regional Servers in the Asia Pacific region. The system will be dedicated to receive and deliver images of disaster struck areas observed by Asia Pacific earth observation satellites by request of the Sentinel Asia members via WINDS satellite or 'Kizuna'. Sentinel Asia is an initiative of collaboration between space agencies and disaster management agencies, applying remote sensing and web-GIS technologies to assist disaster management in Asia Pacific. When a disaster occurred, participating members will make an Emergency Observation Request (EOR) to the Asian Disaster Reduction Centre (ADRC). Subsequently, the Data Provider Node (DPN) will execute the emergency observation using the participating earth observation satellites. The requested images then will be processed and analysed and later it will be uploaded on the Sentinel Asia website to be utilised for disaster management and mitigation by the requestor and any other international agencies related to the disaster. Although the occurrences of large scale natural disasters are statistically seldom in Malaysia, but we can never be sure with the unpredictable earth climate nowadays. This paper will demonstrate the advantage of using Sentinel Asia Step2 for local disaster management. Case study will be from the recent local disaster occurrences. In addition, this paper also will recommend a local disaster management support system by using the Sentinel Asia Step2 facilities in ANGKASA

  18. A novel butt-joint scheme for the preparation of electro-absorptive lasers

    International Nuclear Information System (INIS)

    Cheng Yuanbing; Pan Jiaoqing; Zhou Fan; Feng Wen; Wang Baojun; Zhu Hongliang; Zhao Lingjuan; Wang Wei

    2008-01-01

    A 1.55 μm InGaAsP/InGaAsP multiple-quantum-well electro-absorption modulator (EAM) monolithically integrated with a distributed feedback laser (DFB) diode has been realized based on a novel butt-joint scheme by ultra-low metal-organic vapour phase epitaxy for the first time. The threshold current of 25 mA and an extinction ratio of more than 30 dB are obtained by using the novel structure. The beam divergence angles at the horizontal and vertical directions are as small as 19.3 deg. x 13 deg., respectively, without a spot-size converter by undercutting the InGaAsP active region. The capacitance of the ridge waveguide device with a deep mesa buried by polyimide was reduced down to 0.30 pF

  19. Study of the joining of polycarbonate panels in butt joint configuration through friction stir welding

    Science.gov (United States)

    Astarita, Antonello; Boccarusso, Luca; Carrino, Luigi; Durante, Massimo; Minutolo, Fabrizio Memola Capece; Squillace, Antonino

    2018-05-01

    Polycarbonate sheets, 3 mm thick, were successfully friction stir welded in butt joint configuration. Aiming to study the feasibility of the process and the influence of the process parameters joints under different processing conditions, obtained by varying the tool rotational speed and the tool travel speed, were realized. Tensile tests were carried out to characterize the joints. Moreover the forces arising during the process were recorded and carefully studied. The experimental outcomes proved the feasibility of the process when the process parameters are properly set, joints retaining more than 70% of the UTS of the base material were produced. The trend of the forces was described and explained, the influence of the process parameters was also introduced.

  20. Merging high resolution geophysical and geochemical surveys to reduce exploration risk at glass buttes, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Patrick [Ormat Nevada, Inc., Reno, NV (United States); Fercho, Steven [Ormat Nevada, Inc., Reno, NV (United States); Perkin, Doug [Ormat Nevada, Inc., Reno, NV (United States); Martini, Brigette [Corescan Inc., Ascot (Australia); Boshmann, Darrick [Oregon State Univ., Corvallis, OR (United States)

    2015-06-01

    The engineering and studies phase of the Glass Buttes project was aimed at reducing risk during the early stages of geothermal project development. The project’s inclusion of high resolution geophysical and geochemical surveys allowed Ormat to evaluate the value of these surveys both independently and in combination to quantify the most valuable course of action for exploration in an area where structure, permeability, and temperature are the most pressing questions. The sizes of the thermal anomalies at Glass Buttes are unusually large. Over the course of Phase I Ormat acquired high resolution LIDAR data to accurately map fault manifestations at the surface and collected detailed gravity and aeromagnetic surveys to map subsurface structural features. In addition, Ormat collected airborne hyperspectral data to assist with mapping the rock petrology and mineral alteration assemblages along Glass Buttes faults and magnetotelluric (MT) survey to try to better constrain the structures at depth. Direct and indirect identification of alteration assemblages reveal not only the geochemical character and temperature of the causative hydrothermal fluids but can also constrain areas of upflow along specific fault segments. All five datasets were merged along with subsurface lithologies and temperatures to predict the most likely locations for high permeability and hot fluids. The Glass Buttes temperature anomalies include 2 areas, totaling 60 km2 (23 mi2) of measured temperature gradients over 165° C/km (10° F/100ft). The Midnight Point temperature anomaly includes the Strat-1 well with 90°C (194 °F) at 603 m (1981 ft) with a 164 °C/km (10°F/100ft) temperature gradient at bottom hole and the GB-18 well with 71°C (160 °F) at 396 m (1300 ft) with a 182°C/km (11°F/100ft) gradient. The primary area of alteration and elevated temperature occurs near major fault intersections associated with Brothers Fault Zone and Basin and Range systems. Evidence for faulting is

  1. The Western Environmental Technology Office (WETO), Butte, Montana. Technology summary (Revised)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This document has been prepared by the US Department of Energy`s (DOE`s) Office of Environmental Management (EM) Office of Science and Technology (OST) to highlight its research, development, demonstration, testing, and evaluation (RDDT&E) activities funded through the Western environmental Technology Office (WETO) in Butte, Montana. Technologies and processes described in this document have the potential to enhance DOE`s cleanup and waste management efforts, as well as improve US industry`s competitiveness in global environmental markets. The information presented in this document has been assembled from recently produced OST documents that highlight technology development activities within each of the OST program elements and Focus Areas. This document presents one in a series for each of DOE`s Operations Office and Energy Technology Centers.

  2. The Western Environmental Technology Office (WETO), Butte, Montana. Technology summary (Revised)

    International Nuclear Information System (INIS)

    1996-03-01

    This document has been prepared by the US Department of Energy's (DOE's) Office of Environmental Management (EM) Office of Science and Technology (OST) to highlight its research, development, demonstration, testing, and evaluation (RDDT ampersand E) activities funded through the Western environmental Technology Office (WETO) in Butte, Montana. Technologies and processes described in this document have the potential to enhance DOE's cleanup and waste management efforts, as well as improve US industry's competitiveness in global environmental markets. The information presented in this document has been assembled from recently produced OST documents that highlight technology development activities within each of the OST program elements and Focus Areas. This document presents one in a series for each of DOE's Operations Office and Energy Technology Centers

  3. Residual stress in a thick section high strength T-butt weld

    International Nuclear Information System (INIS)

    Pearce, S.V.; Linton, V.M.; Oliver, E.C.

    2008-01-01

    Residual stresses in a structure are generated as a result of the various fabrication and welding processes used to make the component. Being able to quantify these residual stresses is a key step in determining the continuing integrity of a structure in service. In this work, the residual stresses around a high strength, quenched and tempered steel T-butt web to curved plate weld have been measured using neutron strain scanning. The results show that the residual stresses near the weld were dominated by the welding residual stresses, while the stresses further from the weld were dominated by the bending residual stresses. The results suggest that the combination of welding-induced residual stress and significant pre-welding residual stress, as in the case of a thick bent section of plate can significantly alter the residual stress profile from that in a flat plate

  4. A Study on the Saving Method of Plate Jigs in Hull Block Butt Welding

    Science.gov (United States)

    Ko, Dae-Eun

    2017-11-01

    A large amount of plate jigs is used for alignment of welding line and control of welding deformations in hull block assembly stage. Besides material cost, the huge working man-hours required for working process of plate jigs is one of the obstacles in productivity growth of shipyard. In this study, analysis method was proposed to simulate the welding deformations of block butt joint with plate jigs setting. Using the proposed analysis method, an example simulation was performed for actual panel block joint to investigate the saving method of plate jigs. Results show that it is possible to achieve two objectives of quality accuracy of the hull block and saving the plate jig usage at the same time by deploying the plate jigs at the right places. And the proposed analysis method can be used in establishing guidelines for the proper use of plate jigs in block assembly stage.

  5. Application of ultrasonic NDT technique for butt fusion joints of plastic pipes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Gyung; Lim, Hyung Taik; Choi, Jeong Guen; Lee, Jae Myung [ANSCO, Daejeon (Korea, Republic of)

    2016-05-15

    The long term-durability and the soundness of the plastic pipe have been sufficiently verified through use of the plastic pipe during the past several decades. Recently, as the pipe material have been constantly developed, the application of the plastic pipe is expanded to various industrial fields, such as an increase of a use pressure, the bigger diameter of the pipe, etc. In a nuclear power plant where a carbon steel pipe and a stainless steel pipe are mainly used as a safety class III buried pipe, safety in an operation is seriously threatened by abrasion, heat deterioration or the like, frequently generated in a metal pipe. Therefore, in order to provide an alternate to this problem there is a rising interest on using high-density polyethylene (HDPE) pipes which are known to provide much enhanced corrosion, abrasion and impact resistant properties. With polyethylene piping, one of the issue that is being looked into is the integrity of butt-fusion joint. At the present time the Referencing Code and Standard for the NDT technology of for butt fusion joint of the plastic pipe have not yet established. An optimum inspection parameters were determined according to the thickness of the HDPE pipe. It was also confirmed that most of the detection results of two techniques have matched with each other. In the PAUT, it is easy to distinguish signals with from the flaws made by the thin plate and the void. Also the resolving power of PAUT on the detection in the depth direction has been demonstrated to be satisfactory.

  6. Microstructure and mechanical properties of resistance upset butt welded 304 austenitic stainless steel joints

    International Nuclear Information System (INIS)

    Sharifitabar, M.; Halvaee, A.; Khorshahian, S.

    2011-01-01

    Graphical abstract: Three different microstructural zones formed at different distances from the joint interface in resistance upset butt welding of 304 austenitic stainless steel. Highlights: → Evaluation of microstructure in resistance upset welding of 304 stainless steel. → Evaluation of welding parameters effects on mechanical properties of the joint. → Introducing the optimum welding condition for joining stainless steel bars. -- Abstract: Resistance upset welding (UW) is a widely used process for joining metal parts. In this process, current, time and upset pressure are three parameters that affect the quality of welded products. In the present research, resistance upset butt welding of 304 austenitic stainless steel and effect of welding power and upset pressure on microstructure, tensile strength and fatigue life of the joint were investigated. Microstructure of welds were studied using scanning electron microscopy (SEM). X-ray diffraction (XRD) analysis was used to distinguish the phase(s) that formed at the joint interface and in heat affected zone (HAZ). Energy dispersive spectroscopy (EDS) linked to the SEM was used to determine chemical composition of phases formed at the joint interface. Fatigue tests were performed using a pull-push fatigue test machine and the fatigue properties were analyzed drawing stress-number of cycles to failure (S-N) curves. Also tensile strength tests were performed. Finally tensile and fatigue fracture surfaces were studied by SEM. Results showed that there were three different microstructural zones at different distances from the joint interface and delta ferrite phase has formed in these regions. There was no precipitation of chromium carbide at the joint interface and in the HAZ. Tensile and fatigue strengths of the joint decreased with welding power. Increasing of upset pressure has also considerable influence on tensile strength of the joint. Fractography of fractured samples showed that formation of hot spots at

  7. BioSentinel: Developing a Space Radiation Biosensor

    Science.gov (United States)

    Santa Maria, Sergio R.

    2015-01-01

    BioSentinel is an autonomous fully self-contained science mission that will conduct the first study of the biological response to space radiation outside low Earth orbit (LEO) in over 40 years. The 4-unit (4U) BioSentinel biosensor system, is housed within a 6-Unit (6U) spacecraft, and uses yeast cells in multiple independent microfluidic cards to detect and measure DNA damage that occurs in response to ambient space radiation. Cell growth and metabolic activity will be measured using a 3-color LED detection system and a metabolic indicator dye with a dedicated thermal control system per fluidic card.

  8. Detection of induced seismicity effects on ground surface using data from Sentinel 1A/1B satellites

    Science.gov (United States)

    Milczarek, W.

    2017-12-01

    Induced seismicity is the result of human activity and manifests itself in the form of shock and vibration of the ground surface. One of the most common factors causing the occurrence of induced shocks is underground mining activity. Sufficiently strong high-energy shocks may cause displacements of the ground surface. This type of shocks can have a significant impact on buildings and infrastructure. Assessment of the size and influence of induced seismicity on the ground surface is one of the major problems associated with mining activity. In Poland (Central Eastern Europe) induced seismicity occurs in the area of hard coal mining in the Upper Silesian Coal Basin and in the area of the Legnica - Głogów Copper Basin.The study presents an assessment of the use of satellite radar data (SAR) for the detection influence of induced seismicity in mining regions. Selected induced shocks from the period 2015- 2017 which occurred in the Upper Silesian Coal Basin and the Legnica - Głogów Copper Basin areas have been analyzed. In the calculations SAR data from the Sentinel 1A and Sentinel 1B satellites have been used. The results indicate the possibility of quickly and accurate detection of ground surface displacements after an induced shock. The results of SAR data processing were compared with the results from geodetic measurements. It has been shown that SAR data can be used to detect ground surface displacements on the relative small regions.

  9. Comparison of 2002 Water Year and Historical Water-Quality Data, Upper Gunnison River Basin, Colorado

    Science.gov (United States)

    Spahr, N.E.

    2003-01-01

    Introduction: Population growth and changes in land-use practices have the potential to affect water quality and quantity in the upper Gunnison River basin. In 1995, the U.S. Geological Survey (USGS), in cooperation with local sponsors, City of Gunnison, Colorado River Water Conservation District, Crested Butte South Metropolitan District, Gunnison County, Mount Crested Butte Water and Sanitation District, National Park Service, Town of Crested Butte, and Upper Gunnison River Water Conservancy District, established a water-quality monitoring program in the upper Gunnison River basin to characterize current water-quality conditions and to assess the effects of increased urban development and other land-use changes on water quality. The monitoring network has evolved into two groups of stations, stations that are considered as long term and stations that are rotational. The long-term stations are monitored to assist in defining temporal changes in water quality (how conditions have changed over time). The rotational stations are monitored to assist in the spatial definition of water-quality conditions (how conditions differ throughout the basin) and to address local and short term concerns. Another group of stations (rotational group 2) will be chosen and sampled beginning in water year 2004. Annual summaries of the water-quality data from the monitoring network provide a point of reference for discussions regarding water-quality sampling in the upper Gunnison River basin. This summary includes data collected during water year 2002. The introduction provides a map of the sampling locations, definitions of terms, and a one-page summary of selected water-quality conditions at the network stations. The remainder of the summary is organized around the data collected at individual stations. Data collected during water year 2002 are compared to historical data (data collected for this network since 1995), state water-quality standards, and federal water-quality guidelines

  10. Gray-scale contrast-enhanced utrasonography in detecting sentinel lymph nodes: An animal study

    International Nuclear Information System (INIS)

    Wang Yuexiang; Cheng Zhigang; Li Junlai; Tang Jie

    2010-01-01

    Objective: To investigate the usefulness of gray-scale contrast-enhanced ultrasonography for detecting sentinel lymph nodes. Methods: Contrast-enhanced ultrasonography was performed in five normal dogs (four female and one male) after subcutaneous administration of a sonographic contrast agent (Sonovue, Bracco, Milan, Italy). Four distinct regions in each animal were examined. After contrast-enhanced ultrasonography, 0.8 ml of blue dye was injected into the same location as Sonovue and the sentinel lymph nodes were detected by surgical dissection. The findings of contrast-enhanced ultrasonography were compared with those of the blue dye. Results: Twenty-one sentinel lymph nodes were detected by contrast-enhanced ultrasonography while 23 were identified by blue dye with surgical dissection. Compared with the blue dye, the detection rate of enhanced ultrasonography for the sentinel lymph nodes is 91.3% (21/23). Two patterns of enhancement in the sentinel lymph nodes were observed: complete enhancement (5 sentinel lymph nodes) and partial enhancement (16 sentinel lymph nodes). The lymphatic channels were demonstrated as hyperechoic linear structures leading from the injection site and could be readily followed to their sentinel lymph nodes. Histopathologic examination showed proliferation of lymphatic follicles or lymphatic sinus in partial enhanced sentinel lymph nodes while normal lymphatic tissue was demonstrated in completely enhanced sentinel lymph nodes. Conclusions: Sonovue combined with gray-scale contrast-enhanced ultrasonography may provide a feasible method for detecting sentinel lymph nodes.

  11. Sentinel Node Detection in Head and Neck Malignancies: Innovations in Radioguided Surgery

    Directory of Open Access Journals (Sweden)

    L. Vermeeren

    2009-01-01

    Full Text Available Sentinel node mapping is becoming a routine procedure for staging of various malignancies, because it can determine lymph node status more precisely. Due to anatomical problems, localizing sentinel nodes in the head and neck region on the basis of conventional images can be difficult. New diagnostic tools can provide better visualization of sentinel nodes. In an attempt to keep up with possible scientific progress, this article reviews new and innovative tools for sentinel node localization in this specific area. The overview comprises a short introduction of the sentinel node procedure as well as indications in the head and neck region. Then the results of SPECT/CT for sentinel node detection are described. Finally, a portable gamma camera to enable intraoperative real-time imaging with improved sentinel node detection is described.

  12. Penile lymphoscintigraphy for sentinel node identification

    International Nuclear Information System (INIS)

    Valdes Olmos, R.A.; Hoefnagel, C.A.; Tanis, P.J.; Jansen, L.; Nieweg, O.E.; Meinhardt, W.; Horenblas, S.

    2001-01-01

    Lymphoscintigraphy for sentinel node (SN) identification has been extensively validated in breast cancer and melanoma. The aim of this study was to evaluate the findings of lymphoscintigraphy for SN identification in carcinoma of the penis. Lymphoscintigraphy was performed in 74 consecutive patients (mean age 62.2 years, range 28-87 years) with clinically lymph node-negative squamous cell carcinoma of the penis (stage T2 or greater). Following local anaesthesia by xy-locaine 10% spray, technetium-99m nanocolloid (mean dose 64.8 MBq, range 40-131 MBq) in a volume of 0.3-0.4 ml was injected intradermally around the tumour. Shortly after injection, a 20-min dynamic study was performed with a dual-head gamma camera; subsequently, static anterior and lateral images were obtained at 30 min and 2 h using simultaneous cobalt-57 flood source transmission scanning. 57 Co-assisted skin marking defined SN location for gamma probe/blue dye-guided biopsy, which was performed the next day. The SN visualization rate was 97% (72/74). Lymphatic drainage was bilateral in 81% of the cases (58/72), exclusively to the left groin in 13% (9/72) and only to the right groin in 6%. Bilateral lymph node drainage was synchronous in 38% (22/58) and asynchronous in 62% (in 18 patients the initial route was the left groin, and in the other 18, the right groin). Visualization before 30 min occurred in 66 patients (93%), in 64 of them (88%) already during the dynamic study. A total of 173 SNs were visualized (85 in the right groin, 88 in the left groin). Pitfalls were caused by inguinal skin contamination during injection (four patients) and intracavernous administration (one patient). At surgery, a total of 161 SNs were identified and removed. Sixteen patients (22%) had a tumour-positive SN and underwent standard regional lymph node dissection subsequently. During follow-up (median 28 months, range 3-74 months), two patients with a negative SN developed lymph node metastases in the mapped basin

  13. Penile lymphoscintigraphy for sentinel node identification

    Energy Technology Data Exchange (ETDEWEB)

    Valdes Olmos, R.A.; Hoefnagel, C.A. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Nuclear Medicine; Tanis, P.J.; Jansen, L.; Nieweg, O.E. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Surgery; Meinhardt, W.; Horenblas, S. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Urology

    2001-05-01

    Lymphoscintigraphy for sentinel node (SN) identification has been extensively validated in breast cancer and melanoma. The aim of this study was to evaluate the findings of lymphoscintigraphy for SN identification in carcinoma of the penis. Lymphoscintigraphy was performed in 74 consecutive patients (mean age 62.2 years, range 28-87 years) with clinically lymph node-negative squamous cell carcinoma of the penis (stage T2 or greater). Following local anaesthesia by xy-locaine 10% spray, technetium-99m nanocolloid (mean dose 64.8 MBq, range 40-131 MBq) in a volume of 0.3-0.4 ml was injected intradermally around the tumour. Shortly after injection, a 20-min dynamic study was performed with a dual-head gamma camera; subsequently, static anterior and lateral images were obtained at 30 min and 2 h using simultaneous cobalt-57 flood source transmission scanning. {sup 57}Co-assisted skin marking defined SN location for gamma probe/blue dye-guided biopsy, which was performed the next day. The SN visualization rate was 97% (72/74). Lymphatic drainage was bilateral in 81% of the cases (58/72), exclusively to the left groin in 13% (9/72) and only to the right groin in 6%. Bilateral lymph node drainage was synchronous in 38% (22/58) and asynchronous in 62% (in 18 patients the initial route was the left groin, and in the other 18, the right groin). Visualization before 30 min occurred in 66 patients (93%), in 64 of them (88%) already during the dynamic study. A total of 173 SNs were visualized (85 in the right groin, 88 in the left groin). Pitfalls were caused by inguinal skin contamination during injection (four patients) and intracavernous administration (one patient). At surgery, a total of 161 SNs were identified and removed. Sixteen patients (22%) had a tumour-positive SN and underwent standard regional lymph node dissection subsequently. During follow-up (median 28 months, range 3-74 months), two patients with a negative SN developed lymph node metastases in the mapped

  14. SAR Wave Mode Processing- Improvements Towards Sentinel-1 Mission

    Science.gov (United States)

    Johnsen, Harald; Collard, Fabrice

    2013-03-01

    The Sentinel-1 level-2 (L2) ocean product (OCN) has been designed to deliver geophysical parameters related to the wind, waves and surface velocity to a large panel of end-users. Each L2 OCN product contains up to three geophysical components: the radial velocity (RVL), the ocean surface wind field (OWI) and the ocean swell wave spectra (OSW) components. The Sentinel-1 Level 2 OSW component is the two-dimensional ocean surface wave spectra estimated from a Sentinel-1 Level 1 Single-Look Complex (SLC) SAR image by inversion of the corresponding image cross-spectra. The cross spectra are computed by performing inter-looking in azimuth followed by co- and cross-spectra estimation among the detected individual look images. The image from which a single OSW is computed can be a SLC vignette from the WV mode, or a co-polarized subimage extracted from a SM SLC image. The experiences with ASAR have shown the need to improve the modulation transfer functions (MTF), especially the wind dependency in the RAR MTF. The OSW processing scheme is an upgraded version of the ASAR WM Level 2 processing accounting for these findings. The Sentinel-1 Level 2 OSW processing has been evaluated using ASAR WM and ASAR SM data, and preliminary key results are presented in this paper.

  15. Continuous Morbidity Registration at Dutch Sentinel General Practice Network 2009.

    NARCIS (Netherlands)

    Donker, G.A.

    2011-01-01

    The Mexican flu pandemic was limited to a mild pandemic, although the flu incidence rate was higher than in the previous three seasons. At the peak of the epidemic 189 per 100.000 registered patients consulted their general practitioner (GP). The sentinel GP’s of NIVEL registered the number of new

  16. Sentinel nodes outside lymph node basins in patients with melanoma

    NARCIS (Netherlands)

    Roozendaal, GK; de Vries, JDH; van Poll, D; Jansen, L; Nieweg, OE; Kroon, BBR; Schraffordt Koops, H.

    Background: Lymphoscintigraphy occasionally reveals hot spots outside lymph node basins in patients with melanoma. The aim of this study was to evaluate such abnormally located hot spots. Methods: Sentinel node biopsy was studied prospectively in 379 patients with clinically localized cutaneous

  17. Sentinel node biopsy for melanoma: a study of 241 patients

    DEFF Research Database (Denmark)

    Chakera, Annette Hougaard; Drzewiecki, Krzysztof Tadeusz; Jakobsen, Annika Loft

    2004-01-01

    The aim of this study was to evaluate the sentinel node biopsy (SNB) technique for melanoma using both radiocolloid and blue dye in 241 clinically N0 patients with melanomas >1.0 mm, or thinner lesions exhibiting regression/ulceration. We showed that an increase in injected radioactivity increased...

  18. Red Fox as Sentinel for Blastomyces dermatitidis, Ontario, Canada.

    Science.gov (United States)

    Nemeth, Nicole M; Campbell, G Douglas; Oesterle, Paul T; Shirose, Lenny; McEwen, Beverly; Jardine, Claire M

    2016-07-01

    Blastomyces dermatitidis, a fungus that can cause fatal infection in humans and other mammals, is not readily recoverable from soil, its environmental reservoir. Because of the red fox's widespread distribution, susceptibility to B. dermatitidis, close association with soil, and well-defined home ranges, this animal has potential utility as a sentinel for this fungus.

  19. Search for an optimal colloid for sentinel node imaging

    International Nuclear Information System (INIS)

    Imam, S.K.; Killingsworth, M.

    2005-01-01

    This study aims at finding a cost-effective and stable colloid of appropriate size to replace antimony sulfide colloid which is now in routine use in Australia for sentinel lymph node (SLN) imaging. For this reason we evaluated three colloids; namely phytate, hepatate and stannous fluoride (SnF 2 ). As colloids of particle size of 100-200 nm seem to be appropriate for sentinel node imaging, the three radiolabelled colloid preparations were filtered through 0.1 and 0.22 μm filters and then studied on electron microscope. Electron microscopy showed that unlike phytate, the particle size of the hepatate and SnF 2 colloids did not increase beyond the size limit of 200 nm over a period of as long as 26 hours. Instead, they remained well within the size limits chosen. The stability of particle size is required for intra-operative gamma probe lymphatic mapping that sometimes may be performed on the following day. Hepatate and SnF 2 colloids appeared to be more suited for sentinel lymph node imaging, the latter being an inhouse product is more cost-effective. Further studies based on nodal uptake and the behavior of these two radiopharmaceuticals in animals is suggested in order to evaluate their potential for future wide-spread application in human sentinel node imaging. (author)

  20. Sentinel-5 instrument: status of design, performance, and development

    Science.gov (United States)

    Gühne, T.; Keim, C.; Bartsch, P.; Weiß, S.; Melf, M.; Seefelder, W.

    2017-09-01

    The Sentinel-5 instrument is currently under development by a consortium led by Airbus Defence and Space in the frame of the European Union Copernicus program. It is a customer furnished item to the MetOp Second Generation satellite platform, which will provide operational meteorological data for the coming decades. Mission objective of the Sentinel-5 is to monitor the composition of the Earth atmosphere for Copernicus Atmosphere Services by taking measurements of trace gases and aerosols impacting air quality and climate with high resolution and daily global coverage. Therefore the Sentinel-5 provides five dispersive spectrometers covering the UV-VIS (270…500 nm), NIR (685 …773 nm) and SWIR (1590…1675 and 2305…2385 nm) spectral bands with resolutions <=1nm. Spatially the Sentinel-5 provides a 108° field of view with a ground sampling of 7.5 x 7 km2 at Nadir. The development program is post PDR and the build-up of the industrial team is finalised. We report on the instrument architecture and design derived from the driving requirements, the predicted instrument performance, and the general status of the program.

  1. VERIFICATION OF THE SENTINEL-4 FOCAL PLANE SUBSYSTEM

    Directory of Open Access Journals (Sweden)

    C. Williges

    2017-05-01

    Full Text Available The Sentinel-4 payload is a multi-spectral camera system which is designed to monitor atmospheric conditions over Europe. The German Aerospace Center (DLR in Berlin, Germany conducted the verification campaign of the Focal Plane Subsystem (FPS on behalf of Airbus Defense and Space GmbH, Ottobrunn, Germany. The FPS consists, inter alia, of two Focal Plane Assemblies (FPAs, one for the UV-VIS spectral range (305 nm … 500 nm, the second for NIR (750 nm … 775 nm. In this publication, we will present in detail the opto-mechanical laboratory set-up of the verification campaign of the Sentinel-4 Qualification Model (QM which will also be used for the upcoming Flight Model (FM verification. The test campaign consists mainly of radiometric tests performed with an integrating sphere as homogenous light source. The FPAs have mainly to be operated at 215 K ± 5 K, making it necessary to exploit a thermal vacuum chamber (TVC for the test accomplishment. This publication focuses on the challenge to remotely illuminate both Sentinel-4 detectors as well as a reference detector homogeneously over a distance of approximately 1 m from outside the TVC. Furthermore selected test analyses and results will be presented, showing that the Sentinel-4 FPS meets specifications.

  2. HIV prevalence in South Sudan: data from the ANC sentinel ...

    African Journals Online (AJOL)

    data, triangulated with data from other sources that will achieve informed consensus about population prevalence. Methodology selection of sample. Sentinel surveillance was conducted among pregnant women aged 15-49 attending ANC. Pregnant women were selected as a proxy for the general population and because ...

  3. The Nodal Location of Metastases in Melanoma Sentinel Lymph Nodes

    DEFF Research Database (Denmark)

    Riber-Hansen, Rikke; Nyengaard, Jens; Hamilton-Dutoit, Stephen

    2009-01-01

    BACKGROUND: The design of melanoma sentinel lymph node (SLN) histologic protocols is based on the premise that most metastases are found in the central parts of the nodes, but the evidence for this belief has never been thoroughly tested. METHODS: The nodal location of melanoma metastases in 149...

  4. Sentinel Lymph Node Dissection in Locally Recurrent Breast Cancer

    DEFF Research Database (Denmark)

    Uth, Charlotte Caspara; Christensen, Mette Haulund; Oldenbourg, Mette Holmqvist

    2015-01-01

    BACKGROUND: The aim of this study was to investigate the use of sentinel lymph node dissection (SLND) in the treatment of patients with locally recurrent breast cancer. METHODS: A total of 147 patients with locally recurrent breast cancer were included from five different breast surgery departments...

  5. [The validity of the sentinel node concept in gastrointestinal cancers].

    Science.gov (United States)

    Kitagawa, Y; Fujii, H; Mukai, M; Ando, N; Kubota, T; Ikeda, T; Ohgami, M; Watanabe, M; Otani, Y; Ozawa, S; Hasegawa, H; Furukawa, T; Nakahara, T; Kubo, A; Kumai, K; Kitajima, M

    2000-03-01

    Although the sentinel node concept has been validated and clinically applied to breast cancer and malignant melanoma, its clinical significance in other solid tumors has not been thoroughly investigated. With regard to gastrointestinal (GI) cancers in particular, our surgeons have been cautious because of the high frequency of skip metastasis and the complicated lymphatic system in the GI tract. We would like to emphasize that so-called skip metastasis has been defined according to anatomic classification of regional lymph nodes and that the lymphatic drainage route must be patient or lesion specific. To test the validity and feasibility of this concept in GI cancers, we have established a radio-guided intraoperative sentinel node navigation system using preoperative endoscopic submucosal injection of radioactive tracer followed by intra-operative gamma-probing. In 131 patients with GI cancers (esophagus: 22, stomach: 71, colorectum: 38), the detection rate of sentinel nades was 91% and overall diagnostic accuracy of lymph node metastasis by sentinel node status was 97%. Initial results suggest further investigation of this procedure as an accurate staging and a minimally invasive approach to early GI cancers.

  6. Thick melanoma: prognostic value of positive sentinel nodes

    NARCIS (Netherlands)

    Vermeeren, Lenka; van der Ent, Fred W. C.; Sastrowijoto, Prapto S. H.; Hulsewé, Karel W. E.

    2009-01-01

    BACKGROUND: Sentinel lymph node biopsy (SNB) is a widely accepted procedure used to accurately stage patients with melanoma. Its value in patients with thick melanoma (Breslow thickness >4 mm) is reason for discussion because of the generally poor prognosis of these patients. The purpose of this

  7. Solar Sentinels: Report of the Science and Technology Definition Team

    Science.gov (United States)

    2006-01-01

    The goal of NASA s Living With a Star (LWS) program is to develop the scientific understanding necessary to effectively address those aspects of the connected Sun Earth system that directly affect life and society. Along with the other elements of LWS, Solar Sentinels aims to discover, understand, and model the heliospheric initiation, propagation, and solar connection of those energetic phenomena that adversely affect space exploration and life and society here on Earth. The Solar Sentinels mission will address the following questions: (1) How, where, and under what circumstances are solar energetic particles (SEPs) accelerated to high energies and how do they propagate through the heliosphere? And (2) How are solar wind structures associated with these SEPs, like CMEs, shocks, and high-speed streams, initiated, propagate, evolve, and interact in the inner heliosphere? The Sentinels STDT recommends implementing this mission in two portions, one optimized for inner heliospheric in-situ measurements and the other for solar remote observations. Sentinels will greatly enhance the overall LWS science return.

  8. 78 FR 67168 - Sixth Annual Sentinel Initiative; Public Workshop

    Science.gov (United States)

    2013-11-08

    ... projects that would be appropriate to determine the feasibility of using Sentinel to evaluate drug safety... hotel information, please refer to http://www.cvent.com/d/jcqhyy . (FDA has verified the Web site... within walking distance of the hotel. If you need special accommodations due to a disability, please...

  9. Lymphoscintigraphic Identification of Sentinel Nodes in Malignant Melanoma

    International Nuclear Information System (INIS)

    Andries, G.; Dindelegan, G.; Ciule, Larisa; Cosgarea, Rodica; Cobzac, Gh.

    2006-01-01

    Full text: The most important prognostic factor in malignant melanoma is the presence or absence of metastasis in lymph nodes. It has been demonstrated the orderly progression of different types of tumours. Sentinel lymph node identification is done lymphoscintigraphically, followed by surgical excision and morpho pathological exam. Material and methods: We studied 33 patients with malignant melanoma (age 26-84 years) divided in 2 subgroups: group A without gamma probe (18 patients) and group B with gamma probe (15 patients). The lymphoscintigraphy (LS) was performed with a totally dose of 20-30 MBq of 99mTc-nanocoloid (Amersham) injected peritumoral or pericicatriceal in 4-6 points in volume of 0,1-0,2 ml per point. Acquisition was performed dynamic for 10-15 min and static at 30-60 min p.i. on perpendicular projections. Patent blue dye was injected prior surgery. In group A has performed sentinel node excision (13 patients) or ELND (4), one patient has died before surgery. In group B sentinel nodes were surgically excised with gamma probe and ELND was performed in patients with positive lymph nodes. Histopathologically, sentinel nodes were stained with HE and in 6 cases with HMB45. Results: In group A we identified the sentinel nodes scintigraphically in all patients (median 1,83±-1,50 nodes, range 1-7). Surgically with PBD were identified 1,69±1,18 sentinel nodes, in 2 patients the SN lymphadenectomy was negative. All nodes excised were histopathologically negative, but in 4 patients loco-regional recurrence or distant metastasis developed. In group B we identified scintigraphically 33 SNs (median 2,20±1,37 nodes, range 1-5) and 4 in transit nodes in 14 patients, 24 of them being blue dye positive (80%), in 1 patient LS was negative. With gamma probe surgeon excised 39 radioactive nodes and 1 SN blue dye positive only, 10 of them being histopathologically positive (25% node metastasis). No metastasis were identified after ELND in patients with positive SNs

  10. Examples of Sentinel-2A Mission Exploitation Results

    Science.gov (United States)

    Koetz, Benjamin; Hoersch, Bianca; Gascon, Ferran; Desnos, Yves-Louis; Seifert, Frank Martin; Paganini, Marc; Ramoino, Fabrizio; Arino, Olivier

    2017-04-01

    The Sentinel-2 Copernicus mission will bring significant breakthrough in the exploitation of space borne optical data. Sentinel-2 time series will transform land cover, agriculture, forestry, in-land water and costal EO applications from mapping to monitoring, from snapshot to time series data analysis, from image-based to pixel-based processing. The 5-days temporal revisiting of the Sentinel-2 satellites, when both units will be operated together, will usher us in a new era for time series analysis at high spatial resolutions (HR) of 10-20 meters. The monitoring of seasonal variations and processes in phenology and hydrology are examples of the many R&D areas to be studied. The mission's large swath and systematic acquisitions will further support unprecedented coverage at the national scale addressing information requirements of national to regional policies. Within ESA programs, such as the Data User Element (DUE), Scientific Exploitation of Operational Missions (SEOM) and Climate Change Initiative (CCI), several R&D activities are preparing the exploitation of the Sentinel-2 mission towards reliable measurements and monitoring of e.g. Essential Climate Variables and indicators for the Sustainable Development Goals. Early Sentinel-2 results will be presented related to a range of applications and scientific domains such as agricultural monitoring at national scale (DUE Sen2Agri), wetland extent and condition over African Ramsar sites (DUE GlobWetland-Africa), land cover mapping for climate change (CCI Land Cover), national land monitoring (Cadaster-Env), forest degradation (DUE ForMoSa), urban mapping (DUE EO4Urban), in-land water quality (DUE SPONGE), map of Mediterranean aquaculture (DUE SMART) and coral reef habitat mapping (SEOM S2-4Sci Coral). The above-mentioned activities are only a few examples from the very active international land imaging community building on the long-term Landsat and Spot heritage and knowledge.

  11. Zika beyond the Americas: Travelers as sentinels of Zika virus transmission. A GeoSentinel analysis, 2012 to 2016

    NARCIS (Netherlands)

    Leder, Karin; Grobusch, Martin P.; Gautret, Philippe; Chen, Lin H.; Kuhn, Susan; Lim, Poh Lian; Yates, Johnnie; McCarthy, Anne E.; Rothe, Camilla; Kato, Yasuyuki; Bottieau, Emmanuel; Huber, Kristina; Schwartz, Eli; Stauffer, William; Malvy, Denis; Shaw, Marc T. M.; Rapp, Christophe; Blumberg, Lucille; Jensenius, Mogens; van Genderen, Perry J. J.; Hamer, Davidson H.

    2017-01-01

    Zika virus (ZIKV) was first isolated in Africa; decades later, caused large outbreaks in the Pacific, and is considered endemic in Asia. We aim to describe ZIKV disease epidemiology outside the Americas, the importance of travelers as sentinels of disease transmission, and discrepancies in travel

  12. Riparian spiders as sentinels of polychlorinated biphenyl contamination across heterogeneous aquatic ecosystems

    Science.gov (United States)

    Kraus, Johanna M.; Gibson, Polly P.; Walters, David M.; Mills, Marc A.

    2017-01-01

    Riparian spiders are being used increasingly to track spatial patterns of contaminants in and fluxing from aquatic ecosystems.However, our understanding of the circumstances under which spiders are effective sentinels of aquatic pollution is limited. The present study tests the hypothesis that riparian spiders may be effectively used to track spatial patterns of sediment pollution by polychlorinated biphenyls (PCBs) in aquatic ecosystems with high habitat heterogeneity. The spatial pattern of ΣPCB concentrations in 2 common families of riparian spiders sampled in 2011 to 2013 generally tracked spatial variation in sediment ΣPCBs across all sites within the Manistique River Great Lakes Area of Concern (AOC), a rivermouth ecosystem located on the south shore of the Upper Peninsula, Manistique (MI,USA) that includes harbor, river, backwater, and lake habitats. Sediment ΣPCB concentrations normalized for total organic carbon explained 41% of the variation in lipid-normalized spider ΣPCB concentrations across 11 sites. Furthermore, 2 common riparian spider taxa (Araneidae and Tetragnathidae) were highly correlated (r2> 0.78) and had similar mean ΣPCB concentrations when averaged acrossall years. The results indicate that riparian spiders may be useful sentinels of relative PCB availability to aquatic and riparian food webs in heterogeneous aquatic ecosystems like rivermouths where habitat and contaminant variability may make the use of aquatic taxa lesseffective. Furthermore, the present approach appears robust to heterogeneity in shoreline development and riparian vegetation that support different families of large web-building spiders. Environ Toxicol Chem 2016;9999:1–9. Published 2016 Wiley Periodicals, Inc. on behalf of SETAC. This article is a US government work and, as such, is in the public domain in the United States of America.

  13. Riparian spiders as sentinels of polychlorinated biphenyl contamination across heterogeneous aquatic ecosystems.

    Science.gov (United States)

    Kraus, Johanna M; Gibson, Polly P; Walters, David M; Mills, Marc A

    2017-05-01

    Riparian spiders are being used increasingly to track spatial patterns of contaminants in and fluxing from aquatic ecosystems. However, our understanding of the circumstances under which spiders are effective sentinels of aquatic pollution is limited. The present study tests the hypothesis that riparian spiders may be effectively used to track spatial patterns of sediment pollution by polychlorinated biphenyls (PCBs) in aquatic ecosystems with high habitat heterogeneity. The spatial pattern of ΣPCB concentrations in 2 common families of riparian spiders sampled in 2011 to 2013 generally tracked spatial variation in sediment ΣPCBs across all sites within the Manistique River Great Lakes Area of Concern (AOC), a rivermouth ecosystem located on the south shore of the Upper Peninsula, Manistique (MI, USA) that includes harbor, river, backwater, and lake habitats. Sediment ΣPCB concentrations normalized for total organic carbon explained 41% of the variation in lipid-normalized spider ΣPCB concentrations across 11 sites. Furthermore, 2 common riparian spider taxa (Araneidae and Tetragnathidae) were highly correlated (r 2  > 0.78) and had similar mean ΣPCB concentrations when averaged across all years. The results indicate that riparian spiders may be useful sentinels of relative PCB availability to aquatic and riparian food webs in heterogeneous aquatic ecosystems like rivermouths where habitat and contaminant variability may make the use of aquatic taxa less effective. Furthermore, the present approach appears robust to heterogeneity in shoreline development and riparian vegetation that support different families of large web-building spiders. Environ Toxicol Chem 2017;36:1278-1286. Published 2016 Wiley Periodicals, Inc. on behalf of SETAC. This article is a US government work and, as such, is in the public domain in the United States of America. Published 2016 Wiley Periodicals, Inc. on behalf of SETAC. This article is a US government work and, as such, is in

  14. Effect of the weld groove shape and pass number on residual stresses in butt-welded pipes

    International Nuclear Information System (INIS)

    Sattari-Far, I.; Farahani, M.R.

    2009-01-01

    This study used finite element techniques to analyze the thermo-mechanical behaviour and residual stresses in butt-welded pipes. The residual stresses were also measured in some welds by using the Hole-Drilling method. The results of the finite element analysis were compared with experimentally measured data to evaluate the accuracy of the finite element modelling. Based on this study, a finite element modelling procedure with reasonable accuracy was developed. The developed FE modelling was used to study the effects of weld groove shape and weld pass number on welding residual stresses in butt-welded pipes. The hoop and axial residual stresses in pipe joints of 6 and 10 mm thickness of different groove shapes and pass number were studied. It is shown that these two parameters may have significant effects on magnitude and distribution of residual stresses in welded pipes.

  15. Busted Butte Phase 2: Introduction and Analytical Modeling of Nonreactive Tracer and Lithium Breakthrough

    International Nuclear Information System (INIS)

    Turin, H.J.; Soll, W.E.

    2002-01-01

    The Busted Butte Unsaturated-Zone Transport Test Facility is located approximately 8 km southeast of Yucca Mountain, and was designed to address uncertainties associated with flow and transport in the UZ site-process models for Yucca Mountain. Busted Butte Phase 2 consisted of a 10m x 10m x 7m test block. From July 1988 through October 2000, complex tracer mixtures were injected continuously at 77 discrete points located along eight parallel 10-m boreholes arranged in two horizontal planes. In August 1999, iodide was added to the tracer mixture to explore the effects of initial hydraulic transients. During the course of the experiment, porewater samples were collected at regular intervals using sorbing-paper collection pads, emplaced into fifteen horizontal and inclined 10-m collection boreholes, oriented perpendicular to the injection boreholes. Potential travel distances ranged from 20 cm to over 500 cm. Nonreactive tracer and weakly sorbing lithium breakthrough was observed at most of the collection points during the injection period. Following termination of injection, approximately 800 rock samples were collected using overcore and mineback techniques, and analyzed for tracer concentration. Rock analyses are discussed in a subsequent paper. To complement complex 3-dimensional finite-element modeling of the entire block, bromide, iodide, and lithium breakthrough onto the collection pads has been modeled with CXTFIT. This simple 1-dimensional analytical code uses a non-linear curve-fitting routine to estimate transport parameters including apparent velocity, dispersivity, and field retardation factors. Preliminary results show that: (1) Bromide and iodide behaved similarly, despite the fact that bromide was injected in a strongly transient flow field, while iodide injection began after flow had approached steady state conditions. (2) With the exception of the closest collection points, tracer velocities remained relatively constant, indicating that transport was

  16. Wired for success: A history of the Butte, Anaconda & Pacific Railway, 1892--1985

    Science.gov (United States)

    Mutschler, Charles Vincent

    The Butte, Anaconda & Pacific Railway (BA&P) was a standard gauge common carrier short line railroad within the state of Montana. A subsidiary of the Anaconda Copper Mining Company, the BA&P was built to carry ore from mines at Butte, Montana to Anaconda, twenty-six miles away, for concentrating and smelting. Other freight and passenger business was of secondary importance. In 1912, when General Electric contracted to convert the BA&P from steam to electric operation, the short line became a proving ground for main line railroad electrification, and the center of attention from advocates for electric power. Electric operation was demonstrated to be mechanically superior to the use of steam locomotives on the BA&P. Immediately after the BA&P proved the technological feasibility of high voltage direct current for moving heavy freight trains, the Chicago Milwaukee & St. Paul (CM&St.P) electrified over 600 miles of transcontinental main line using the basic technology demonstrated on the BA&P. However, on long distances of track with relatively few trains such as the CM&St.P, the capital cost of the electric distribution system exceeded the operational savings obtained by use of electric locomotives. Steam locomotives remained the primary form of railroad motive power in the United States until the 1950's, when the diesel-electric locomotive combined the mechanical efficiency of electric motors with an on-board diesel generating plant, eliminating the need for expensive electric power supply and distribution wires of conventional electrics. The BA&P purchased three diesels in the early 1950's, but relied primarily on its electric locomotives until 1967, when diesel operation became less costly than continued use of electric motive power. The BA&P offers a microcosmic view of the transformation of one industry in response to technological and economic forces as the United States moved from reliance on coal-burning steam power to electric power and internal combustion

  17. Hepatic angiographic findings of ruptured hepatocellular carcinoma: 'Sentinel signs' versus extravasation

    International Nuclear Information System (INIS)

    Yun, Seong Jong; Nam, Deok Ho

    2014-01-01

    This study retrospectively compared the accuracy of angiographic sentinel signs (sentinel vessels, hypovascular areas, and delayed dots) with extravasation in the diagnosis of ruptured hepatocellular carcinoma (HCC). Sixteen patients diagnosed with HCC between March 2007 and November 2011 were evaluated. Among the patients, we identified 32 HCCs (19 ruptured, 13 unruptured), and assessed all HCCs by hepatic angiography with regard to extravasation, sentinel vessels, hypovascular areas, and delayed dots. We compared the sensitivity and specificity of the sentinel signs with those of the extravasation for the diagnosis of a ruptured HCC. For the angiographic diagnosis of a ruptured HCC, the sensitivity of the sentinel signs (sentinel vessel, 63.2%; hypovascular area, 89.5%; delayed dot, 72.7%) was higher than the sensitivity of extravasation (15.8%). The difference in sensitivity between each sentinel sign and extravasation was statistically significant (sentinel vessel, p = 0.012; hypovascular area, p < 0.001; delayed dot, p 0.039). The specificity of sentinel signs for the diagnosis of ruptured HCC was not statistically different from the specificity of extravasation. Sentinel signs are more accurate than extravasation for the angiographic diagnosis of a ruptured HCC.

  18. A Semi-analytical model for creep life prediction of butt-welded joints in cylindrical vessels

    International Nuclear Information System (INIS)

    Zarrabi, K.

    2001-01-01

    There have been many investigations on the life assessment of high temperature weldments used in cylindrical pressure vessels, pipes and tubes over the last two decades or so. But to the author's knowledge, currently, there exists no practical, economical and relatively accurate model for creep life assessment of butt-welded joints in cylindrical pressure vessels. This paper describes a semi-analytical and economical model for creep life assessment of butt-welded joints. The first stage of the development of the model is described where the model takes into account the material discontinuities at the welded joint only. The development of the model to include other factors such as geometrical stress concentrations, residual stresses, etc will be reported separately. It has been shown that the proposed model can estimate the redistributions of stresses in the weld and Haz with an error of less than 4%. It has also been shown that the proposed model can conservatively predict the creep life of a butt-welded joint with an error of less than 16%

  19. A Study on the compensation margin on butt welding joint of Large Steel plates during Shipbuilding construction

    International Nuclear Information System (INIS)

    Kim, J; Jeong, K; Chung, H; Jeong, H; Ji, M; Yun, C; Lee, J

    2015-01-01

    This paper examines the characteristics of butt welding joint shrinkage for shipbuilding and marine structures main plate. The shrinkage strain of butt welding joint which is caused by the process of heat input and cooling, results in the difference between dimensions of the actual parent metal and the dimensions of design. This, in turn, leads to poor quality in the production of ship blocks and reworking through period of correction brings about impediment on improvement of productivity. Through experiments on butt welding joint's shrinkage strain on large structures main plate, the deformation of welding residual stress in the form of I, Y, V was obtained. In addition, the results of experiments indicate that there is limited range of shrinkage in the range of 1 ∼ 2 mm in 11t ∼ 21.5t thickness and the effect of heat transfer of weld appears to be limited within 1000 mm based on one side of seam line so there was limited impact of weight of parent metal on the shrinkage. Finally, it has been learned that Shrinkage margin needs to be applied differently based on groove phenomenon in the design phase in order to minimize shrinkage. (paper)

  20. SPICE: Sentinel-3 Performance Improvement for Ice Sheets

    Science.gov (United States)

    McMillan, M.; Escola, R.; Roca, M.; Thibaut, P.; Aublanc, J.; Shepherd, A.; Remy, F.; Benveniste, J.; Ambrózio, A.; Restano, M.

    2017-12-01

    For the past 25 years, polar-orbiting satellite radar altimeters have provided a valuable record of ice sheet elevation change and mass balance. One of the principle challenges associated with radar altimetry comes from the relatively large ground footprint of conventional pulse-limited radars, which reduces their capacity to make measurements in areas of complex topographic terrain. In recent years, progress has been made towards improving ground resolution, through the implementation of Synthetic Aperture Radar (SAR), or Delay-Doppler, techniques. In 2010, the launch of CryoSat-2 heralded the start of a new era of SAR Interferometric (SARIn) altimetry. However, because the satellite operated in SARIn and LRM mode over the ice sheets, many of the non-interferometric SAR altimeter processing techniques have been optimized for water and sea ice surfaces only. The launch of Sentinel-3, which provides full non-interferometric SAR coverage of the ice sheets, therefore presents the opportunity to further develop these SAR processing methodologies over ice sheets. Here we present results from SPICE, a 2 year study that focuses on (1) developing and evaluating Sentinel-3 SAR altimetry processing methodologies over the Polar ice sheets, and (2) investigating radar wave penetration through comparisons of Ku- and Ka-band satellite measurements. The project, which is funded by ESA's SEOM (Scientific Exploitation of Operational Missions) programme, has worked in advance of the operational phase of Sentinel-3, to emulate Sentinel-3 SAR and pseudo-LRM data from dedicated CryoSat-2 SAR acquisitions made at the Lake Vostok, Dome C and Spirit sites in East Antarctica, and from reprocessed SARIn data in Greenland. In Phase 1 of the project we have evaluated existing processing methodologies, and in Phase 2 we are investigating new evolutions to the Delay-Doppler Processing (DDP) and retracking chains. In this presentation we (1) evaluate the existing Sentinel-3 processing chain by

  1. Petrographic Analysis and Geochemical Source Correlation of Pigeon Peak, Sutter Buttes, CA

    Science.gov (United States)

    Novotny, N. M.; Hausback, B. P.

    2013-12-01

    The Sutter Buttes are a volcanic complex located in the center of the Great Valley north of Sacramento. They are comprised of numerous inter-intruding andesite and rhyolite lava domes of varying compositions surrounded by a shallow rampart of associated tephras. The Pigeon Peak block-and-ash flow sequence is located in the rampart and made up of a porphyritic Biotite bearing Hornblende Andesite. The andesite blocks demonstrate a high degree of propylization in hornblende crystals, highly zoned plagioclase, trace olivine, and display a red to gray color gradation. DAR is an andesite dome located less than one mile from Pigeon Peak. Of the 15 to 25 andesite lava domes within four miles from Pigeon Peak, only DAR displays trace olivine, red to grey color stratification, low biotite content, and propylitized hornblende. These characteristic similarities suggest that DAR may be the source for Pigeon Peak. My investigation used microprobe analysis of the DAR and Pigeon Peak feldspar crystals to identify the magmatic history of the magma body before emplacement. Correlation of the anorthite zoning within the feldspars from both locations support my hypothesis that DAR is the source of the Pigeon Peak block-and-ash flow.

  2. IE Information No. 86-104: Unqualified butt splice connectors identified in qualified penetrations

    International Nuclear Information System (INIS)

    Jordan, E.L.

    1992-01-01

    During an NRC equipment qualification (EQ) inspection at Dresden Nuclear Power Station, May 19--23, 1986, a deficiency was discovered concerning a lack of similarity between tested and installed nylon insulated butt splices in EQ qualified GE electrical penetrations. commonwealth Edison sent four sample splices removed from Quad Cities Nuclear Power Station to Wyle Laboratory to further substantiate their qualification for use in a harsh environment. These splices were identical to those installed at Dresden. During the testing performed at Wyle Laboratory December 4--5, 1986, all four samples exhibited excessive leakage currents to ground when exposed to a steam environment. Commonwealth Edison consequently declared the splices unqualified and shut down its Quad Cities Unit 1 to rework the splices by wrapping them with previously qualified tape. Dresden Unit 2 has similarly reworked the splices by wrapping them with tape. Duane Arnold Energy Center also has commenced a shutdown in order to make repairs. The short circuits that occurred appeared to start by condensation entering the splice between the wire insulation and the nylon tubing. The arcing caused insulation degradation that then allowed arcs to pass through the insulation to the enclosure

  3. Requirements to gap widths and clamping for CO2 laser butt welding

    DEFF Research Database (Denmark)

    Gong, Hui; Juhl, Thomas Winther

    1999-01-01

    In the experimental study of fixturing and gap width requirements a clamping device for laser butt welding of steel sheets has been developed and tested. It has fulfilled the work and made the gap width experiments possible.It has shown that the maximum allowable gap width to some extent...... is inversely related to the welding speed. Also larger laser power leads to bigger allowable gap widths. The focal point position, though, has little influence on the maximum allowable gap width.During analysis X-ray photos show no interior porosity in the weld seam. Other methods have been applied to measure...... responses from variations in welding parameters.The table below lists the results of the study, showing the maximum allowable gap widths and some corresponding welding parameters.Maximum allowable Gap Width; Welding Speed; Laser Power:0.10 mm2 m/min2, 2.6 kW0.15 mm1 m/min2 kW0.20 mm1 m/min2.6 kW0.30 mm0.5 m...

  4. Application of Phased Array Ultrasonic Testing (PAUT) on Single V-Butt Weld Integrity Determination

    International Nuclear Information System (INIS)

    Amry Amin Abas; Mohd Kamal Shah Shamsudin; Norhazleena Azaman

    2015-01-01

    Phased Array Ultrasonic Testing (PAUT) utilizes arrays of piezoelectric elements that are embedded in an epoxy base. The benefit of having such kind of array is that beam forming such as steering and focusing the beam front possible. This enables scanning patterns such as linear scan, sectorial scan and depth focusing scan to be performed. Ultrasonic phased array systems can potentially be employed in almost any test where conventional ultrasonic flaw detectors have traditionally been used. Weld inspection and crack detection are the most important applications, and these tests are done across a wide range of industries including aerospace, power generation, petrochemical, metal billet and tubular goods suppliers, pipeline construction and maintenance, structural metals, and general manufacturing. Phased arrays can also be effectively used to profile remaining wall thickness in corrosion survey applications. The benefits of PAUT are simplifying inspection of components of complex geometry, inspection of components with limited access, testing of welds with multiple angles from a single probe and increasing the probability of detection while improving signal-to-noise ratio. This paper compares the result of inspection on several specimens using PAUT as to digital radiography. The specimens are welded plates with single V-butt weld made of carbon steel. Digital radiography is done using blue imaging plate with x-ray source. PAUT is done using Olympus MX2 with 5 MHz probe consisting of 64 elements. The location, size and length of defect is compared. (author)

  5. Characterization of magnetically impelled arc butt welded T11 tubes for high pressure applications

    Directory of Open Access Journals (Sweden)

    R. Sivasankari

    2015-09-01

    Full Text Available Magnetically impelled arc butt (MIAB welding is a pressure welding process used for joining of pipes and tubes with an external magnetic field affecting arc rotation along the tube circumference. In this work, MIAB welding of low alloy steel (T11 tubes were carried out to study the microstructural changes occurring in thermo-mechanically affected zone (TMAZ. To qualify the process for the welding applications where pressure could be up to 300 bar, the MIAB welds are studied with variations of arc current and arc rotation time. It is found that TMAZ shows higher hardness than that in base metal and displays higher weld tensile strength and ductility due to bainitic transformation. The effect of arc current on the weld interface is also detailed and is found to be defect free at higher values of arc currents. The results reveal that MIAB welded samples exhibits good structural property correlation for high pressure applications with an added benefit of enhanced productivity at lower cost. The study will enable the use of MIAB welding for high pressure applications in power and defence sectors.

  6. Spectral image analysis of the Hopi Buttes volcanic field, Arizona, U.S.A

    International Nuclear Information System (INIS)

    Gabelman, J.W.; Wescott, T.F.

    1987-01-01

    The possibility of economic deposits, the semi-arid environment and the youth of applied remote-sensing technology suit the Hopi Buttes volcanic field as a test site for the application of multispectral image analysis to geologic interpretation and uranium evaluation. All possible enhancements of seasonal images were created in the General Electric interactive multispectral analyzer, model 100, and photographed for study. Contrast and directional edge-enhancement excellently delineated the patterns of megafractures and lineaments which are obscure to ground observation, but may control vent positions. Two sets of orthogonal groups of megafractures are oriented in the cardinal and diagonal directions; they suggest rotation of the stress ellipsoid, or the overlap of stresses from a differently oriented ellipsoid in a neighboring region. A megacircle of vents suggests a deep cylindrical fracture zone and possible incipient cauldron. Other circular areas with unusually abundant travertine maars or volcanic-material-free pipes suggest incipient collapse. Band ratios, density slices and histogram stretches selectively enhanced and differentiated stratigraphic formations, limburgite, tuff, travertine, gypsum-argillized rock and Fe-enriched rock. These were portrayed successfully on thematic map-images. A signature was derived for uraniferous travertine-marl and used to map its distribution. 30 refs.; 24 figs

  7. Identifying Variations in Hydraulic Conductivity on the East River at Crested Butte, CO

    Science.gov (United States)

    Ulmer, K. N.; Malenda, H. F.; Singha, K.

    2016-12-01

    Slug tests are a widely used method to measure saturated hydraulic conductivity, or how easily water flows through an aquifer, by perturbing the piezometric surface and measuring the time the local groundwater table takes to re-equilibrate. Saturated hydraulic conductivity is crucial to calculating the speed and direction of groundwater movement. Therefore, it is important to document data variance from in situ slug tests. This study addresses two potential sources of data variability: different users and different types of slug used. To test for user variability, two individuals slugged the same six wells with water multiple times at a stream meander on the East River near Crested Butte, CO. To test for variations in type of slug test, multiple water and metal slug tests were performed at a single well in the same meander. The distributions of hydraulic conductivities of each test were then tested for variance using both the Kruskal-Wallis test and the Brown-Forsythe test. When comparing the hydraulic conductivity distributions gathered by the two individuals, we found that they were statistically similar. However, we found that the two types of slug tests produced hydraulic conductivity distributions for the same well that are statistically dissimilar. In conclusion, multiple people should be able to conduct slug tests without creating any considerable variations in the resulting hydraulic conductivity values, but only a single type of slug should be used for those tests.

  8. Simulation and experimental study on distortion of butt and T-joints using WELD PLANNER

    International Nuclear Information System (INIS)

    Sulaiman, Mohd Shahar; Manurung, Yupiter HP; Rahim, Mohammad Ridzwan Abdul Mohd; Redza, Ridhwan; Lidam, Robert Ngendang Ak.; Abas, Sunhaji Kiyai; Tham, Ghalib; Haruman, Esa; Chau, Chan Yin

    2011-01-01

    This paper investigates the capability of linear thermal elastic numerical analysis to predict the welding distortion that occurs due to GMAW process. Distortion is considered as the major stumbling block that can adversely affect the dimensional accuracy and thus lead to expensive corrective work. Hence, forecast of distortion is crucially needed and ought to be determined in advance in order to minimize the negative effects, improve the quality of welded parts and finally to reduce the production costs. In this study, the welding deformation was simulated by using relatively new FEM software WELD PLANNER developed by ESI Group. This novel Welding Simulation Solution was employed to predict welding distortion induced in butt and T-joints with thickness of 4 mm. Low carbon steel material was used for the simulation and experimental study. A series of experiments using fully automated welding process were conducted for verification purpose to measure the distortion. By comparing between the simulation and experimental results, it was found out that this program code offered fast solution analysis time in estimating weld induced distortion within acceptable accuracy

  9. Simulation and experimental study on distortion of butt and T-joints using WELD PLANNER

    Energy Technology Data Exchange (ETDEWEB)

    Sulaiman, Mohd Shahar; Manurung, Yupiter HP; Rahim, Mohammad Ridzwan Abdul Mohd; Redza, Ridhwan; Lidam, Robert Ngendang Ak.; Abas, Sunhaji Kiyai; Tham, Ghalib [Universiti Teknologi MARA, Kuala Lumpur (Malaysia); Haruman, Esa [Bakrie University, Jakarta (Indonesia); Chau, Chan Yin [ESI Group, Kuala Lumpur (Malaysia)

    2011-10-15

    This paper investigates the capability of linear thermal elastic numerical analysis to predict the welding distortion that occurs due to GMAW process. Distortion is considered as the major stumbling block that can adversely affect the dimensional accuracy and thus lead to expensive corrective work. Hence, forecast of distortion is crucially needed and ought to be determined in advance in order to minimize the negative effects, improve the quality of welded parts and finally to reduce the production costs. In this study, the welding deformation was simulated by using relatively new FEM software WELD PLANNER developed by ESI Group. This novel Welding Simulation Solution was employed to predict welding distortion induced in butt and T-joints with thickness of 4 mm. Low carbon steel material was used for the simulation and experimental study. A series of experiments using fully automated welding process were conducted for verification purpose to measure the distortion. By comparing between the simulation and experimental results, it was found out that this program code offered fast solution analysis time in estimating weld induced distortion within acceptable accuracy.

  10. Assessment of role of metamorphic remobilization in genesis of uranium ores from Ralston Buttes area, Colorado

    International Nuclear Information System (INIS)

    Chatterjee, S.K.

    1984-01-01

    The Ralston Buttes mining district, the principal source of commercial uranium in the Front Range since the late 1940s, is located northeast of Golden and southeast of the Front Range mineral belt. Uranium ore occurs in veins emplaced in fault breccia in Precambrian metamorphic rocks. The progenitors of the metamorphic rocks are a possible source for the uranium. Hornblende gneisses of the Idaho Springs Formation is the major rock type in the area, thus its origin is a major consideration in assessing the quantity of uranium that might have been contributed by metamorphic processes. To evaluate this, 41 rock samples (19 hornblende gneisses, 7 biotite gneisses, 5 chlorite gneisses, and 10 metapelites) were analyzed for major elements, and 3 rock samples (16 hornblende gneisses, 8 biotite gneisses, 4 chlorite gneisses, and 5 mica schists) were analyzed for trace metals (Rb, Sc, Zr, V, Ni, Co, Cr, Ba, U, and Th). Four samples of hornblende gneiss and 1 sample of mica schists were also analyzed for rare earth elements. Major elements are rare earth data indicate that the hornblende gneiss was derived from sediments and tholeiitic basalts. Trace element data suggest a volcanic provenance for these sediments. Rare earth patterns and uranium and thorium abundances of metapelites are similar to average North American shales. Low uranium and thorium values and low thorium-uranium ratios in hornblende gneisses and mica schists preclude large-scale uranium remobilization during metamorphism of these source rocks

  11. Busted Butte : final report on laboratory radionuclide migration experiments in non-welded tuff under unsaturated and saturated conditions

    International Nuclear Information System (INIS)

    Vandergraaf, T.T.; Drew, D.J.; Ticknor, K.V.; Hamon, C.J.

    2004-01-01

    Three blocks of non-welded tuff, one nominally one cubic foot (trial block) in volume and the other two, nominally one cubic meter (1 m 3 ) in volume, were excavated from the Busted Butte Test Facility on the Nevada Test Site in 1999 and transported to the Atomic Energy of Canada Limited Whiteshell Laboratories in Pinawa, Manitoba. The trial block and one of the 1-m 3 blocks were used for radionuclide migration experiments under unsaturated conditions; the remaining 1-m3 block was used for similar migration experiments under saturated conditions. After a vertical flow of synthetic transport solution was set up under unsaturated conditions, a suite of conservative and chemically reactive radionuclide tracers was injected at volumetric flow rates of 20 mL/hr in the trial block, and 10 mL/hr in two locations on the upper surface of the 1-m 3 block. These flow rates correspond to infiltration rates of about 120 cm/year and about 17 cm/year, respectively. The duration of the migration experiment in the trial block was 87 days, while the migration experiment in the 1-m3 block was performed for a period of 588 days. Results obtained from the migration experiment in the trial block showed that transport of 95m+99 Tc, injected as the pertechnetate (an)ion, was slightly faster than that of the transport solution, using tritiated water ( 3 H 2 0) as a flow indicator. Retardation of 237 Np was consistent with that predicted from results obtained in supporting static batch sorption studies. Post-migration analysis of the flow field in the trial block showed that the front of the 22 Na plume had migrated about half the distance through the block, and that 60 Co and 137 Cs had been retained near the inlet. This observation agrees qualitatively with that predicted from the results obtained in static batch sorption studies. In the larger-scale experiment, the transport behavior of Tc was also very similar to that of the transport solution. None of the other radionuclide tracers

  12. Enhancements to the Sentinel Fireball Network Video Software

    Science.gov (United States)

    Watson, Wayne

    2009-05-01

    The Sentinel Fireball Network that supports meteor imaging of bright meteors (fireballs) has been in existence for over ten years. Nearly five years ago it moved from gathering meteor data with a camera and VCR video tape to a fisheye lens attached to a hardware device, the Sentinel box, which allowed meteor data to be recorded on a PC operating under real-time Linux. In 2006, that software, sentuser, was made available on Apple, Linux, and Window operating systems using the Python computer language. It provides basic video and management functionality and a small amount of analytic software capability. This paper describes the new and attractive future features of the software, and, additionally, it reviews some of the research and networks from the past and present using video equipment to collect and analyze fireball data that have applicability to sentuser.

  13. Axillary web syndrome following sentinel node biopsy for breast cancer.

    Science.gov (United States)

    Nieves Maldonado, S M; Pubul Núñez, V; Argibay Vázquez, S; Macías Cortiñas, M; Ruibal Morell, Á

    2016-01-01

    A 49 year-old woman diagnosed with infiltrating lobular breast carcinoma, underwent a right mastectomy and sentinel node biopsy (SLNB). The resected sentinel lymph nodes were negative for malignancy, with an axillary lymphadenectomy not being performed. In the early post-operative period, the patient reported an axillary skin tension sensation, associated with a painful palpable cord. These are typical manifestations of axillary web syndrome (AWS), a poorly known axillary surgery complication, from both invasive and conservative interventions. By presenting this case we want to focus the attention on a pathological condition, for which its incidence may be underestimated by not including it in SLNB studies. It is important for nuclear medicine physicians to be aware of AWS as a more common complication than infection, seroma, or lymphoedema, and to discuss this possible event with the patient who is consenting to the procedure. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  14. The sentinel node concept in breast cancer: A commentary

    International Nuclear Information System (INIS)

    Canizales, A.L. . E-mail A.L.Canizales@qmul.ac.uk; Al-Yasi, A.; Gambhir, S.; Morris, G.; Granowska, M.; Britton, K.E.

    2004-01-01

    As there are multiple lymphatic pathways from the breast to the axilla with multiple possible choices for a cancer cell or a colloid, it appears intuitively unusual that one node is preferentially 'chosen'. The intuitive response would be that there is an equal chance for a breast cancer cell to travel by any lymphatic pathway to any axillary node at level 1. If this were true, then after a colloid injection into the peritumoural lymphatics or the periareolar lymphatic plexus, such a colloid has a similar chance to travel to any level 1 axillary node, be it an involved node or an uninvolved node. We have tried to resolve this conflict between intuition and practice. It was tested by identifying and measuring the activity of the radiolabelled colloid in the nodes removed in an axillary clearance and in the sentinel node or nodes after applying a sentinel node technique similar to that of Veronesi et al. The histology of all the nodes that were counted was analysed so that the colloid activity in each node was able to be correlated with its histology, whether it was involved with cancer or not involved. Measurements were obtained in those patients, in whom there were both involved and uninvolved nodes in the axillae. The colloid counts in cpm/g of each node were compared with the related sentinel node findings either involved with cancer or not involved. These were calculated either as the involved to uninvolved that is a 'positive' to 'negative' ratio. The results were that the activity ratio of all involved axillary nodes to uninvolved axillary nodes was about 4:1. The involved Sentinel nodes had on average over 25 times the uptake of the uninvolved Sentinel nodes. P value was <0.009 for a significant difference between colloid uptake in sentinel nodes with positive histology and those with negative histology. It is a new observation that involved axillary nodes show greater uptake of the colloid than uninvolved nodes in all patients where there are both involved

  15. Estimating Velocities of Glaciers Using Sentinel-1 SAR Imagery

    Science.gov (United States)

    Gens, R.; Arnoult, K., Jr.; Friedl, P.; Vijay, S.; Braun, M.; Meyer, F. J.; Gracheva, V.; Hogenson, K.

    2017-12-01

    In an international collaborative effort, software has been developed to estimate the velocities of glaciers by using Sentinel-1 Synthetic Aperture Radar (SAR) imagery. The technique, initially designed by the University of Erlangen-Nuremberg (FAU), has been previously used to quantify spatial and temporal variabilities in the velocities of surging glaciers in the Pakistan Karakoram. The software estimates surface velocities by first co-registering image pairs to sub-pixel precision and then by estimating local offsets based on cross-correlation. The Alaska Satellite Facility (ASF) at the University of Alaska Fairbanks (UAF) has modified the software to make it more robust and also capable of migration into the Amazon Cloud. Additionally, ASF has implemented a prototype that offers the glacier tracking processing flow as a subscription service as part of its Hybrid Pluggable Processing Pipeline (HyP3). Since the software is co-located with ASF's cloud-based Sentinel-1 archive, processing of large data volumes is now more efficient and cost effective. Velocity maps are estimated for Single Look Complex (SLC) SAR image pairs and a digital elevation model (DEM) of the local topography. A time series of these velocity maps then allows the long-term monitoring of these glaciers. Due to the all-weather capabilities and the dense coverage of Sentinel-1 data, the results are complementary to optically generated ones. Together with the products from the Global Land Ice Velocity Extraction project (GoLIVE) derived from Landsat 8 data, glacier speeds can be monitored more comprehensively. Examples from Sentinel-1 SAR-derived results are presented along with optical results for the same glaciers.

  16. Indications of sentinel node biopsy in thin melanoma

    Directory of Open Access Journals (Sweden)

    Fernanda Braga Silva

    2010-06-01

    Full Text Available Objective: To assess data on survival, recurrence and histological factors in positive and negative sentinel lymph nodes in thin melanoma cases. Methods: A systematic review was conducted on observational studies in four databases (Cochrane Library, Medline, Embase and Lilacs. Positive and negative micrometastases in sentinel lymph node biopsy were compared regarding the clinical outcomes – death and recurrence – and six histological factors – vertical growth phase, Breslow thickness, Clark level, ulceration, regression and mitosis rate. Results: Positive sentinel lymph node is statistically associated with greater risk of death in six studies (OR: 7.2; 95%CI [2.37-21.83]; I2 0% and also to recurrence in three studies (OR: 30.7; 95%CI [12.58-74.92]; I2 36%. Comparing positive and negative groups, the histological factors predicting positive sentinel nodes and poor prognosis were: mitosis rate ≥ 5/mm2 (OR: 16.29; 95%CI [3.64-72.84]; I2 40%; VGP (OR: 2.93; 95%CI [1.08-7.93]; I2 59%; Breslow thickness ≥ 0.75mm (OR: 2.23; 95%CI [1.29-3.86]; I2 0%; and Clark level IV-V (OR: 1.61; 95%CI [1.06-2.44]; I2 34%. Conclusions: The statistically significant results associated with the presence of micrometastases in thin melanomas were Breslow thickness ≥ 0.75 mm, Clark level IV-V and mitoses ≥ 5/mm2, absence of regression. This histological factor of ulceration was associated, but not statistically significant.

  17. Sentinel node biopsy in head and neck cancer

    DEFF Research Database (Denmark)

    Ross, Gary L; Soutar, David S; Gordon MacDonald, D

    2004-01-01

    BACKGROUND: The aim was to determine the reliability and reproducibility of sentinel node biopsy (SNB) as a staging tool in head and neck squamous cell carcinoma (HNSCC) for T1/2 clinically N0 patients by means of a standardized technique. METHODS: Between June 1998 and June 2002, 227 SNB procedu...... cavity/oropharynx in a standardized fashion by centers worldwide. For the majority of these tumors the SNB technique can be used alone as a staging tool....

  18. CTC Sentinel. Volume 6, Issue 9. September 2013

    Science.gov (United States)

    2013-09-01

    central government’s control and militants’ ability—and willingness—to quietly blend in.38 A security official in Hadramawt explained the group’s...safari.”17 8 Secunder Kermani, “Drone Victim’s Somalia Visits Probed,” BBC, May 30, 2013. 9 Personal interview, Tam Hussein, community worker who...shared vision of the Center products like the CTC Sentinel could not be produced. If you are interested in learning more about how to support the

  19. Role of sentinel lymph node biopsy in oral cancer.

    Science.gov (United States)

    Calabrese, L; Bruschini, R; Ansarin, M; Giugliano, G; De Cicco, C; Ionna, F; Paganelli, G; Maffini, F; Werner, J A; Soutar, D

    2006-12-01

    Squamous cell carcinoma of the oral cavity represents about 2% of all malignant neoplasms and 47% of those developing in the head and neck area. The tongue is the most common site involved, and this incidence is increasing mainly in young people, possibly related to human papilloma virus infections. Prognosis depends on the stage: the 5-year survival rate of tongue squamous cell carcinoma, whatever the T stage, is 73% in pN0 cases, 40% in patients with positive nodes without extracapsular spread (pNl ECS-), and 29% when nodes are metastatic with extracapsular spread (pNl ECS+: p > or = 0.0001). Nodal micrometastases (cN0 pN1) are found in up to 50% of cN0 tongue squamous cell carcinoma patients operated on the neck. At present, no clinical, imaging staging modalities or biological markers are available to diagnose nodal micrometastases. The sentinel node biopsy has been tested since 1996 in order to find a solution to this problem. The sentinel node is the first node reached by the lymphatic stream, assuming an orderly and sequential drainage from the tumour site, and should be predictive of the nodal stage. According to the literature, sentinel node biopsy is a reliable technique in selected cN0 cases, but the procedure is still experimental and should not be performed outside validation trials. Successful application of sentinel node biopsy in the head and neck region requires surgical experience and specific technical devices, including pre-operative lymphoscintigraphy and intra-operative gamma-probe. Moreover, dynamic lymphoscintigraphy seems to be able to show the lymphatic stream from the primary tumour and could allow a selective neck dissection to be tailored thus reducing the related morbidity.

  20. CTC Sentinel. Volume 9, Issue 2, February 2016

    Science.gov (United States)

    2016-06-02

    Islamic State side. See Derek Henry Flood: “The Islamic State Raises Its Black Flag Over The Caucasus,” CTC Sentinel 8:6 (2015): pp. 1-4. Dr. Guido...Qalamun,” [Hezbollah Holds Funeral for Child Killed in Al-Qalamun], Al-Araby Al-Jadid, April 28, 2015. 2 Lin Jenkins , “Isis video shows killing of

  1. Sentinel-1A/B Combined Product Geolocation Accuracy

    Directory of Open Access Journals (Sweden)

    Adrian Schubert

    2017-06-01

    Full Text Available Sentinel-1A and -1B are twin spaceborne synthetic aperture radar (SAR sensors developed and operated by the European Space Agency under the auspices of the Copernicus Earth observation programme. Launched in April 2014 and April 2016, Sentinel-1A and -1B are currently operating in tandem, in a common orbital configuration to provide an increased revisit frequency. In-orbit commissioning was completed for each unit within months of their respective launches, and level-1 SAR products generated by the operational SAR processor have been geometrically calibrated. In order to compare and monitor the geometric characteristics of the level-1 products from both units, as well as to investigate potential improvements, products from both satellites have been monitored since their respective commissioning phases. In this study, we present geolocation accuracy estimates for both Sentinel-1 units based on the time series of level-1 products collected thus far. While both units were demonstrated to be performing consistently, and providing SAR data products according to the nominal product specifications, a subtle beam- and mode-dependent azimuth bias common to the data from both units was identified. A method for removing the bias is proposed, and the corresponding improvement to the geometric accuracies is demonstrated and quantified.

  2. Laboratory-supported influenza surveillance in Victorian sentinel general practices.

    Science.gov (United States)

    Kelly, H; Murphy, A; Leong, W; Leydon, J; Tresise, P; Gerrard, M; Chibo, D; Birch, C; Andrews, R; Catton, M

    2000-12-01

    Laboratory-supported influenza surveillance is important as part of pandemic preparedness, for identifying and isolating candidate vaccine strains, for supporting trials of anti-influenza drugs and for refining the influenza surveillance case definition in practice. This study describes the implementation of laboratory-supported influenza surveillance in Victorian sentinel general practices and provides an estimate of the proportion of patients with an influenza-like illness proven to have influenza. During 1998 and 1999, 25 sentinel general practices contributed clinical surveillance data and 16 metropolitan practices participated in laboratory surveillance. Serological, virus-antigen detection, virus culture and multiplex polymerase chain reaction procedures were used to establish the diagnosis of influenza. Two laboratories at major teaching hospitals in Melbourne provided additional data on influenza virus identification. General practice sentinel surveillance and laboratory identification of influenza provided similar data on the pattern of influenza in the community between May and September. The clinical suspicion of influenza was confirmed in 49 to 54 per cent of cases seen in general practice.

  3. Ocean Wave Parameters Retrieval from Sentinel-1 SAR Imagery

    Directory of Open Access Journals (Sweden)

    Weizeng Shao

    2016-08-01

    Full Text Available In this paper, a semi-empirical algorithm for significant wave height (Hs and mean wave period (Tmw retrieval from C-band VV-polarization Sentinel-1 synthetic aperture radar (SAR imagery is presented. We develop a semi-empirical function for Hs retrieval, which describes the relation between Hs and cutoff wavelength, radar incidence angle, and wave propagation direction relative to radar look direction. Additionally, Tmw can be also calculated through Hs and cutoff wavelength by using another empirical function. We collected 106 C-band stripmap mode Sentinel-1 SAR images in VV-polarization and wave measurements from in situ buoys. There are a total of 150 matchup points. We used 93 matchups to tune the coefficients of the semi-empirical algorithm and the rest 57 matchups for validation. The comparison shows a 0.69 m root mean square error (RMSE of Hs with a 18.6% of scatter index (SI and 1.98 s RMSE of Tmw with a 24.8% of SI. Results indicate that the algorithm is suitable for wave parameters retrieval from Sentinel-1 SAR data.

  4. SENTINEL trademark technical basis report for Limerick. Final report

    International Nuclear Information System (INIS)

    Burns, E.T.; Lee, L.K.; Mitman, J.T.; Vanover, D.E.; Wilson, D.K.

    1997-12-01

    PECO Energy in cooperation with the Electric Power Research Institute (EPRI) installed the SENTINEL trademark software at its Limerick Generating Station. This software incorporates models of the safety and support systems which are used to display the defense in depth present in the plant and a quantitative assessment of the plant risks during proposed on-line maintenance. During the past year, PECO Energy personnel have used this display to evaluate the safety of proposed on-line maintenance schedules. The report describes the motivation for and the development of the SENTINEL software. It describes the generation of Safety Function Assessment Trees and Plant Transient Assessment Trees and their use in evaluating the level of defense-in-depth of key plant safety functions and the susceptibility of the plant to critical transient events. Their results are displayed by color indicators ranging from green, through yellow and orange to red to show increasingly hazardous conditions. The report describes the use of the Limerick Probabilistic Safety Assessment within the SENTINEL code to calculate an instantaneous core damage frequency and the criteria by which this frequency is translated to a color indicator. Finally, the report describes the Performance Criteria Assessment which tracks and trends system/train unavailability to document conformance to the requirements of the Maintenance Rule

  5. Sentinel lymph node surgery in prostate cancer using magnetic particles.

    Science.gov (United States)

    Winter, Alexander; Engels, Svenja; Wawroschek, Friedhelm

    2018-03-01

    Superparamagnetic iron oxide nanoparticles (SPIONs) are tested to identify sentinel lymph nodes (SLNs) to exploit the advantages of targeted pelvic SLN dissection (sPLND), while circumventing the disadvantages of established radioactive labeling. Here we review recent studies about sPLND in prostate cancer (PCa), including the first results of SLN detection using intraprostatic SPION-injection. A recent systematic literature review reveals that the diagnostic accuracy of sPLND is comparable with extended PLND (ePLND). sPLND combined with ePLND achieve better node removal by increasing the number of affected nodes. The first sentinel-based nomogram predicting lymph node invasion is established. A sentinel-nomogram update provides comparative predictions relative to ePLND models. sPLND using a magnetometer and SPIONs as a tracer is successful whenever applied to PCa, and SLN identification using MRI after intraprostatic injection of SPIONs is feasible. SLNs are present in an unexpectedly high number outside the ePLND template. SLN detection outside the ePLND template and the increased diagnostic value of sPLND compared with ePLND supports the individualized extension of PLND using sPLND in PCa. SPION-MRI, combined with a hand-held magnetometer, provides a nonradioactive technique for preoperative and intraoperative SLN localization. Further studies are required to evaluate the effects of sPLND on oncological outcomes.

  6. [Sentinel node in melanoma and breast cancer. Current considerations].

    Science.gov (United States)

    Vidal-Sicart, S; Vilalta Solsona, A; Alonso Vargas, M I

    2015-01-01

    The main objectives of sentinel node (SN) biopsy is to avoid unnecessary lymphadenectomies and to identify the 20-25% of patients with occult regional metastatic involvement. This technique reduces the associated morbidity from lymphadenectomy and increases the occult lymphatic metastases identification rate by offering the pathologist the or those lymph nodes with the highest probability of containing metastatic cells. Pre-surgical lymphoscintigraphy is considered a "road map" to guide the surgeon towards the sentinel nodes and to localize unpredictable lymphatic drainage patterns. The SPECT/CT advantages include a better SN detection rate than planar images, the ability to detect SNs in difficult to interpret studies, better SN depiction, especially in sites closer to the injection site and better anatomic localization. These advantages may result in a change in the patient's clinical management both in melanoma and breast cancer. The correct SN evaluation by pathology implies a tumoral load stratification and further prognostic implication. The use of intraoperative imaging devices allows the surgeon a better surgical approach and precise SN localization. Several studies reports the added value of such devices for more sentinel nodes excision and a complete monitoring of the whole procedure. New techniques, by using fluorescent or hybrid tracers, are currently being developed. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  7. ORAM-SENTINEL development at Calvert Cliffs. Final report

    International Nuclear Information System (INIS)

    1998-05-01

    Baltimore Gas and Electric, in cooperation with EPRI, has installed ORAM-SENTINEL trademark software at Calvert Cliffs Nuclear Power Plant. This software incorporates models of the safety and support systems that are used to display the defense-in-depth present in the plant and a quantitative assessment of plant risks during proposed on-line maintenance. During 1997, Baltimore Gas and Electric personnel became familiar with the formal computerized Safety Assessment process associated with on-line and outage maintenance. The report describes the motivation for and the development of ORAM-SENTINEL software. It describes generation of Safety Function Assessment Trees and Plant Transient Assessment Trees and their use in evaluating the level of defense-in-depth of key plant safety functions and plant susceptibility to critical transient events. To show decreasing safety conditions, their results are displayed by color indicators ranging from green through yellow and orange to red. The report describes use of the Calvert Probabilistic Safety Assessment with ORAM-SENTINEL code to calculate an instantaneous core damage frequency and the criteria by which this frequency is translated to a color indicator

  8. SENTINEL trademark technical basis report for Peach Bottom. Final report

    International Nuclear Information System (INIS)

    1998-04-01

    PECO Energy in cooperation with the Electric Power Research Institute (EPRI) installed the SENTINEL trademark software at its Peach Bottom Atomic Power Station (PBAPS). This software incorporates models of the safety and support systems which are used to display the defense in depth present in the plant and a quantitative assessment of the plant risks during proposed on-line maintenance. During the past nine months, PECO Energy personnel have used this display to evaluate the safety of proposed on-line maintenance schedules. The report describes the motivation for and the development of the SENTINEL software. It describes the generation of Safety Function Assessment Trees and Plant Transient Assessment Trees and their use in evaluating the level of defense-in-depth of key plant safety functions and the susceptibility of the plant to critical transient events. Their results are displayed by color indicators ranging from green, through yellow and orange, to red to show increasingly hazardous conditions. The report describes the use of the PBAPS Probabilistic Safety Assessment within the SENTINEL code to calculate an instantaneous core damage frequency and the criteria by which this frequency is translated to a color indicator

  9. [Japanese sentinel project and contribution of laboratory medicine].

    Science.gov (United States)

    Nakashima, Naoki

    2013-06-01

    Ordinary passive surveillance (generally spontaneous reporting) of adverse effects of medical products is not enough to manage medical risks/safety. The Japanese government, following the "sentinel initiative" by the US government, started the "Japanese sentinel project" as an active surveillance of medical products with the Pharmaceuticals and Medical Devices Agency(PMDA). Using entire prescription data in the hospital information system, data on laboratory examinations, diagnosis, and therapy specific to an adverse effect are checked by detecting differences between before and after prescription of a specific medical product to extract adverse effects and calculate their correct frequency in the surveillance. The project uses standard masters and protocols to analyze data among medial institutes by installation of the SS-MIX standard storage system. Ten hospitals were selected in 2011 to join the project, and the entire system and network will be implemented in those hospitals and PMDA until 2013 fiscal year. JLAC10 is used in the project as the laboratory examination code of the Japanese Society of Laboratory Medicine. Many incorrect coding and ambiguous coding rules were found by voluntary surveillance of 6 of the 10 hospitals in the project. Thus, the Council on Standardized Master Operation of Clinical Laboratory Examinations will launch in 2013 to improve and maintain JLAC10, which is essential not only for the Japanese sentinel project but also for data utilization by many other projects.

  10. A Study of Sentinel-1 TOPS Mode Co-registration

    Directory of Open Access Journals (Sweden)

    WU Wenhao

    2017-09-01

    Full Text Available The TOPS imaging mode is the default operation mode of Sentinel-1 satellite, an overall azimuth coregistration accuracy of better than 0.001 pixels is required for this configuration in order to achieve the interferometric phase bias is less than three degrees. Based on the high accuracy of Sentinel-1 orbital information, this paper demonstrates a sufficiently high coregistration accuracy is able to be achieved by geometrical coregistration algorithm, which satisfies the pre-requirement for estimating the residual coregistration error by enhanced spectral diversity method. Based on DORIS open source software, a coregistration approach for Sentinel-A TOPS mode is implemented by an algorithm of geometric prediction of the shifts using precise orbit information, and an improvement on coregistration processing is achieved by enhanced spectral diversity. An interferometric phase jump between two Bursts could be caused by surface deformation in azimuth direction, and introduce a disturbance when estimating the residual coregistration error by enhanced spectral diversity method. In this paper, based on related theory analysis and real data processing test, an outlier detection estimation method is proposed to reduce the disturbance of enhanced spectral diversity coregistration method, which is caused by phase jumps.

  11. Verification of the Sentinel-4 focal plane subsystem

    Science.gov (United States)

    Williges, Christian; Uhlig, Mathias; Hilbert, Stefan; Rossmann, Hannes; Buchwinkler, Kevin; Babben, Steffen; Sebastian, Ilse; Hohn, Rüdiger; Reulke, Ralf

    2017-09-01

    The Sentinel-4 payload is a multi-spectral camera system, designed to monitor atmospheric conditions over Europe from a geostationary orbit. The German Aerospace Center, DLR Berlin, conducted the verification campaign of the Focal Plane Subsystem (FPS) during the second half of 2016. The FPS consists, of two Focal Plane Assemblies (FPAs), two Front End Electronics (FEEs), one Front End Support Electronic (FSE) and one Instrument Control Unit (ICU). The FPAs are designed for two spectral ranges: UV-VIS (305 nm - 500 nm) and NIR (750 nm - 775 nm). In this publication, we will present in detail the set-up of the verification campaign of the Sentinel-4 Qualification Model (QM). This set up will also be used for the upcoming Flight Model (FM) verification, planned for early 2018. The FPAs have to be operated at 215 K +/- 5 K, making it necessary to exploit a thermal vacuum chamber (TVC) for the test accomplishment. The test campaign consists mainly of radiometric tests. This publication focuses on the challenge to remotely illuminate both Sentinel-4 detectors as well as a reference detector homogeneously over a distance of approximately 1 m from outside the TVC. Selected test analyses and results will be presented.

  12. The Copernicus Sentinel 4 mission: a geostationary imaging UVN spectrometer for air quality monitoring

    Science.gov (United States)

    Bazalgette Courrèges-Lacoste, G.; Sallusti, M.; Bulsa, G.; Bagnasco, G.; Veihelmann, Ben; Riedl, S.; Smith, D. J.; Maurer, R.

    2017-09-01

    Sentinel-4 is an imaging UVN (UV-VIS-NIR) spectrometer, developed by Airbus Defence and Space under ESA contract in the frame of the joint EU/ESA COPERNICUS program. The mission objective is the operational monitoring of trace gas concentrations for atmospheric chemistry and climate applications - hence the motto of Sentinel-4 "Knowing what we breathe". Sentinel-4 will provide accurate measurements of key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, methane, and aerosol properties over Europe and adjacent regions from a geostationary orbit (see Fig. 1). In the family of already flown UVN spectrometers (SCIAMACHY, OMI, GOME and GOME 2) and of those spectrometers currently under development (Sentinel-5p and Sentinel-5), Sentinel-4 is unique in being the first geostationary UVN mission. Furthermore, thanks to its 60-minutes repeat cycle measurements and high spatial resolution (8x8 km2), Sentinel-4 will increase the frequency of cloud-free observations, which is necessary to assess troposphere variability. Two identical Sentinel-4 instruments (PFM and FM-2) will be embarked, as Customer Furnished Item (CFI), fully verified, qualified and calibrated respectively onto two EUMETSAT satellites: Meteosat Third Generation-Sounder 1 and 2 (MTG-S1 and MTG-S2), whose Flight Acceptance Reviews are presently planned respectively in Q4 2021 and Q1 2030. This paper gives an overview of the Sentinel-4 system1 architecture, its design and development status, current performances and the key technological challenges.

  13. Sentinel node biopsy before neoadjuvant chemotherapy spares breast cancer patients axillary lymph node dissection.

    Science.gov (United States)

    van Rijk, Maartje C; Nieweg, Omgo E; Rutgers, Emiel J T; Oldenburg, Hester S A; Olmos, Renato Valdés; Hoefnagel, Cornelis A; Kroon, Bin B R

    2006-04-01

    Neoadjuvant chemotherapy in breast cancer patients is a valuable method to determine the efficacy of chemotherapy and potentially downsize the primary tumor, which facilitates breast-conserving therapy. In 18 studies published about sentinel node biopsy after neoadjuvant chemotherapy, the sentinel node was identified in on average 89%, and the false-negative rate was on average 10%. Because of these mediocre results, no author dares to omit axillary clearance just yet. In our institute, sentinel lymph node biopsy is performed before neoadjuvant chemotherapy. The aim of this study was to evaluate our experience with this approach. Sentinel node biopsy was performed before neoadjuvant chemotherapy in 25 T2N0 patients by using lymphoscintigraphy, a gamma ray detection probe, and patent blue dye. Axillary lymph node dissection was performed after chemotherapy if the sentinel node contained metastases. Ten patients had a tumor-positive axillary sentinel node, and one patient had an involved lateral intramammary node. Four patients had additional involved nodes in the completion lymph node dissection specimen. The other 14 patients (56%) had a tumor-negative sentinel node and did not undergo axillary lymph node dissection. No recurrences have been observed after a median follow-up of 18 months. Fourteen (56%) of the 25 patients were spared axillary lymph node dissection when the sentinel node was found to be disease free. Performing sentinel node biopsy before neoadjuvant chemotherapy seems successful and reliable in patients with T2N0 breast cancer.

  14. Sentinel lymph node biopsy from the vantage point of an oncologic surgeon.

    Science.gov (United States)

    Wilson, Lori L

    2009-01-01

    Sentinel lymph node biopsy has greatly influenced the surgical management of clinically localized primary melanoma. Lymphatic mapping and sentinel lymph node biopsy have been used for the selective management of the draining regional lymph node basin of primary cutaneous melanoma. Oncologic surgeons have adopted this procedure to selectively identify occult nodal status in melanoma patients who are at a higher risk of regional metastasis. The current standard of treatment of tumor-positive sentinel lymph node metastasis is immediate completion lymphadenectomy, but considerable debate surrounds the utility of this procedure. This contribution reviews development, technical aspects, selective management of the lymph node basin, and sentinel lymph node biopsy techniques.

  15. Sentinel Lymph Node Biopsy in Breast Cancer: Predictors of Axillary and Non-Sentinel Lymph Node Involvement

    Directory of Open Access Journals (Sweden)

    Hakan Postacı

    2013-12-01

    Full Text Available Background: Sentinel lymph node biopsy is a standard method for the evaluation of axillary status in patients with T1-2N0M0 breast cancers. Aims: To determine the prognostic significance of primary tumour-related clinico-histopathological factors on axillary and non-sentinel lymph node involvement of patients who underwent sentinel lymph node biopsy. Study design: Retrospective clinical study. Methods: In the present study, 157 sentinel lymph node biopsies were performed in 151 consecutive patients with early stage breast cancer between June 2008 and December 2011. Results: Successful lymphatic mapping was obtained in 157 of 158 procedures (99.4%. The incidence of larger tumour size (2.543±1.21 vs. 1.974±1.04, lymphatic vessel invasion (70.6% vs. 29.4%, blood vessel invasion (84.2% vs. 15.8%, and invasive lobular carcinoma subtype (72.7% vs. 27.3% were statistically significantly higher in patients with positive SLNs. Logistic stepwise regression analysis disclosed tumour size (odds ratio: 1.51, p=0.0021 and lymphatic vessel invasion (odds ratio: 4.68, p=0.001 as significant primary tumour-related prognostic determinants of SLN metastasis. Conclusion: A close relationship was identified between tumour size and lymphatic vessel invasion of the primary tumour and axillary lymph node involvement. However, the positive predictive value of these two independent variables is low and there is no compelling evidence to recommend their use in routine clinical practice.

  16. Method for strength calculating of structural elements of mobile machines for flash butt welding of rails

    Directory of Open Access Journals (Sweden)

    Andriy Valeriy Moltasov

    2017-12-01

    Full Text Available Purpose. The subject of this study is the strength of the loaded units of mobile machines for flash butt welding by refining high-strength rails. The theme of the work is related to the development of a technique for strength calculating of the insulation of the central axis of these machines. The aim of the paper is to establish the mathematical dependence of the pressure on the insulation on the magnitude of deflections of the central axis under the action of the upset force. Design/methodology/approach. Using the Mohr’s method, the displacements of the investigated sections of the central axis under the action of the upset force and the equivalent load distributed along the length of the insulation were calculated. The magnitude of the load distributed along the length of the insulation equivalent to the draft force was determined from the condition that the displacements of the same cross sections are equal under the action of this load and under the action of the upset force. Results. An analytical expression for establishing the relationship between the pressure acting on the insulation and the magnitude of the upset force and the geometric dimensions of the structural elements of the machine was obtained. Based on the condition of the strength of the insulation for crushing, an analytical expression for establishing the relationship between the length of insulation and the size of the upset force, the geometric dimensions of the structural elements of the machine, and the physical and mechanical properties of the insulation material was obtained. Originality/cost. The proposed methodology was tested in the calculation and design of the K1045 mobile rail welding machine, 4 of which is currently successfully used in the USA for welding rails in hard-to-reach places.

  17. Unravelling the magmatic system beneath a monogenetic volcanic complex (Jagged Rocks Complex, Hopi Buttes, AZ, USA)

    Science.gov (United States)

    Re, G.; Palin, J. M.; White, J. D. L.; Parolari, M.

    2017-12-01

    The Jagged Rocks complex is the eroded remnant of the plumbing systems of closely spaced monogenetic alkaline volcanic centres in the southern Hopi Buttes Volcanic Field (AZ, USA). It contains different clinopyroxene populations with distinctive textures and geochemical patterns. In the Northwestern part of the complex, which exposes the best developed system of conduits, most of the clinopyroxenes consist of large- to medium-sized resorbed cores overgrown by euhedral rims (type 1), small moderately resorbed greenish cores with the same overgrown rims (type 2), and phlogopite as an accessory phase. By contrast, in the Southern part of the complex the majority of clinopyroxenes are euhedral with oscillatory zonation (type 3) and are accompanied by minor euhedral olivine. The differences between these mineral assemblages indicate a composite history of crystallization and magmatic evolution for the two parts of the complex, governed by different mechanisms and ascent patterns from a single source at 50 km depth (16 kbar). The Northwest system preserves a high-pressure assemblage that cooled rapidly from near-liquidus conditions, suggesting direct ascent from the source to the surface at high-to-moderate transport rates (average 1.25 m/s). By contrast, the Southern system represents magma that advanced upward at much lower overall ascent rates, stalling at times to form small-volume mid-crustal storage zones (e.g., sills or a network of sheeted intrusions); this allowed the re-equilibration of the magma at lower pressure ( 30 km; 8 kbar), and led to nucleation and growth of euhedral clinopyroxene and olivine phenocrysts.

  18. Comparison of 2006-2007 Water Years and Historical Water-Quality Data, Upper Gunnison River Basin, Colorado

    Science.gov (United States)

    Solberg, P.A.; Moore, Bryan; Smits, Dennis

    2009-01-01

    Population growth and changes in land use have the potential to affect water quality and quantity in the upper Gunnison River basin. In 1995, the U.S. Geological Survey (USGS), in cooperation with the Bureau of Land Management, City of Gunnison, Colorado River Water Conservation District, Crested Butte South Metropolitan District, Gunnison County, Hinsdale County, Mount Crested Butte Water and Sanitation District, National Park Service, Town of Crested Butte, Upper Gunnison River Water Conservancy District, and Western State College established a water-quality monitoring program in the upper Gunnison River basin to characterize current water-quality conditions and to assess the effects of increased urban development and other land-use changes on water quality. The monitoring network has evolved into two groups of stations - stations that are considered long term and stations that are considered rotational. The long-term stations are monitored to assist in defining temporal changes in water quality (how conditions may change over time). The rotational stations are monitored to assist in the spatial definition of water-quality conditions (how conditions differ throughout the basin) and to address local and short-term concerns. Some stations in the rotational group were changed beginning in water year 2007. Annual summaries of the water-quality data from the monitoring network provide a point of reference for discussions regarding water-quality monitoring in the upper Gunnison River basin. This summary includes data collected during water years 2006 and 2007. The introduction provides a map of the sampling sites, definitions of terms, and a one-page summary of selected water-quality conditions at the network stations. The remainder of the summary is organized around the data collected at individual stations. Data collected during water years 2006 and 2007 are compared to historical data, State water-quality standards, and Federal water-quality guidelines. Data were

  19. Comparison of Water Years 2004-05 and Historical Water-Quality Data, Upper Gunnison River Basin, Colorado

    Science.gov (United States)

    Spahr, Norman E.; Hartle, David M.; Diaz, Paul

    2008-01-01

    Population growth and changes in land use have the potential to affect water quality and quantity in the upper Gunnison River Basin. In 1995, the U.S. Geological Survey (USGS), in cooperation with the Bureau of Land Management, City of Gunnison, Colorado River Water Conservation District, Crested Butte South Metropolitan District, Gunnison County, Hinsdale County, Mount Crested Butte Water and Sanitation District, National Park Service, Town of Crested Butte, Upper Gunnison River Water Conservancy District, and Western State College, established a water-quality monitoring program in the upper Gunnison River Basin to characterize current water-quality conditions and to assess the effects of increased urban development and other land-use changes on water quality. The monitoring network has evolved into two groups of stations - stations that are considered long term and stations that are considered rotational. The long-term stations are monitored to assist in defining temporal changes in water quality (how conditions may change over time). The rotational stations are monitored to assist in the spatial definition of water-quality conditions (how conditions differ throughout the basin) and to address local and short-term concerns. Some stations in the rotational group were changed beginning in water year 2007. Annual summaries of the water-quality data from the monitoring network provide a point of reference for discussions regarding water-quality monitoring in the upper Gunnison River Basin. This summary includes data collected during water years 2004 and 2005. The introduction provides a map of the sampling sites, definitions of terms, and a one-page summary of selected water-quality conditions at the network stations. The remainder of the summary is organized around the data collected at individual stations. Data collected during water years 2004 and 2005 are compared to historical data, State water-quality standards, and Federal water-quality guidelines. Data were

  20. Radionavigated detection of sentinel nodes in breast carcinoma--first experiences of our department.

    Science.gov (United States)

    Duchaj, B; Chvalny, P; Vesely, J; Makaiova, I; Durdik, S; Straka, V; Palaj, J; Procka, V; Aksamitova, K; Skraskova, S; Banki, P; Kovacova, S; Galbavy, S

    2010-01-01

    Biopsy and histological evaluation of sentinel lymphatic node limits the axillary node dissection only in cases of positive histological finding and decreases the occurrence of postoperative complications related to the axillary node dissection. We used radiotracer SentiScint, Medi-Radiopharma Ltd, Hungary and preoperatively administered blue dye--Blue Patenté V, Guebert, Aulnay-Sous-Bios, France. 11 (18%) patients were subdued to deep peritimorous application of radiotracer, 10 (16.4%) to sub/intradermal application over the lesions and n 40 (65.6%) patients the application was sub/intradermal and periareolar. The patients underwent an operation protocol of corresponding quadrantectomy, radionavigated blue-dye sentinel node biopsy and axillary dissection. From May 2006 to June 2008, we examined 61 patients with breast carcinoma. They underwent radionavigated and blue-dye sentinel node biopsy. We detected 57 (93.4%) sentinel nodes with preoperative scintigraphy, of which only 51 (83.6%) were detected peroperatively and underwent histological evaluation. In six (9.8%) cases, the "frozen cut" histology of the primary lesion had shown a benign lesion; hence no sentinel node biopsy or axillary disection was performed. 12 (19.7%) of 51 histologically evaluated sentinel nodes had metastatic invasion. We retrospectively compared the histological fund in sentinel and axillary nodes in patients with metastatic sentinel nodes. In 6 (16.6%) cases, the sentinel node was positive of metastatic invasion but axillary nodes were histologically negative, in 6 (16.6%) cases the sentinel node and axillary nodes were positive for metastatic invasion. We observed falsely negative findings in 3 (8.3%) patients with negative histological fund in the sentinel node, but positive axillary nodes (Tab. 3, Fig. 2, Ref. 11). Full Text (Free, PDF) www.bmj.sk.

  1. SENTINEL-2 Services Library - efficient way for exploration and exploitation of EO data

    Science.gov (United States)

    Milcinski, Grega; Batic, Matej; Kadunc, Miha; Kolaric, Primoz; Mocnik, Rok; Repse, marko

    2017-04-01

    With more than 1.5 million scenes available covering over 11 billion sq. kilometers of area and containing half a quadrillion of pixels, Sentinel-2 is becoming one of the most important MSI datasets in the world. However, the vast amount of data makes it difficult to work with. This is certainly an important reason, why the number of Sentinel based applications is not as high as it could be at this point. We will present a Copernicus Award [1] winning service for archiving, processing and distribution of Sentinel data, Sentinel Hub [2]. It makes it easy for anyone to tap into global Sentinel archive and exploit its rich multi-sensor data to observe changes in the land. We will demonstrate, how one is able not just to observe imagery all over the world but also to create its own statistical analysis in a matter of seconds, performing comparison of different sensors through various time segments. The result can be immediately observed in any GIS tool or exported as a raster file for post-processing. All of these actions can be performed on a full, worldwide, S-2 archive (multi-temporal and multi-spectral). To demonstrate the technology, we created a publicly accessible web application, called "Sentinel Playground" [3], which makes it possible to query Sentinel-2 data anywhere in the world, and experts-oriented tool "EO Browser" [4], where it is also possible to observe land changes through longer period by using historical Landsat data as well. [1] http://www.copernicus-masters.com/index.php?anzeige=press-2016-03.html [2] http://www.sentinel-hub.com [3] http://apps.sentinel-hub.com/sentinel-playground/ [4] http://apps.eocloud.sentinel-hub.com/eo-browser/

  2. NOAA high resolution sea surface winds data from Synthetic Aperture Radar (SAR) on the Sentinel-1 satellites

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set consists of high resolution sea surface winds data produced from Synthetic Aperture Radar (SAR) on board Sentinel-1A and Sentinel-1B satellites. This...

  3. A novel weld seam detection method for space weld seam of narrow butt joint in laser welding

    Science.gov (United States)

    Shao, Wen Jun; Huang, Yu; Zhang, Yong

    2018-02-01

    Structured light measurement is widely used for weld seam detection owing to its high measurement precision and robust. However, there is nearly no geometrical deformation of the stripe projected onto weld face, whose seam width is less than 0.1 mm and without misalignment. So, it's very difficult to ensure an exact retrieval of the seam feature. This issue is raised as laser welding for butt joint of thin metal plate is widely applied. Moreover, measurement for the seam width, seam center and the normal vector of the weld face at the same time during welding process is of great importance to the welding quality but rarely reported. Consequently, a seam measurement method based on vision sensor for space weld seam of narrow butt joint is proposed in this article. Three laser stripes with different wave length are project on the weldment, in which two red laser stripes are designed and used to measure the three dimensional profile of the weld face by the principle of optical triangulation, and the third green laser stripe is used as light source to measure the edge and the centerline of the seam by the principle of passive vision sensor. The corresponding image process algorithm is proposed to extract the centerline of the red laser stripes as well as the seam feature. All these three laser stripes are captured and processed in a single image so that the three dimensional position of the space weld seam can be obtained simultaneously. Finally, the result of experiment reveals that the proposed method can meet the precision demand of space narrow butt joint.

  4. In-process monitoring and adaptive control for gap in micro butt welding with pulsed YAG laser

    International Nuclear Information System (INIS)

    Kawahito, Yousuke; Kito, Masayuki; Katayama, Seiji

    2007-01-01

    A gap is one of the most important issues to be solved in laser welding of a micro butt joint, because the gap results in welding defects such as underfilling or a non-bonded joint. In-process monitoring and adaptive control has been expected as one of the useful procedures for the stable production of sound laser welds without defects. The objective of this research is to evaluate the availability of in-process monitoring and adaptive control in micro butt welding of pure titanium rods with a pulsed neodymium : yttrium aluminium garnet (Nd : YAG) laser beam of a 150 μm spot diameter. It was revealed that a 45 μm narrow gap was detected by the remarkable jump in a reflected light intensity due to the formation of the molten pool which could bridge the gap. Heat radiation signal levels increased in proportion to the sizes of molten pools or penetration depths for the respective laser powers. As for adaptive control, the laser peak power was controlled on the basis of the reflected light or the heat radiation signals to stably produce a sound deeply penetrated weld reduced underfilling. In the case of a 100 μm gap, the underfilling was greatly reduced by half smaller than those made with a conventional rectangular pulse shape in seam welding as well as spot welding with a pulsed Nd : YAG laser beam. Consequently, the adaptive control of the laser peak power on the basis of in-process monitoring could reduce the harmful effects due to a gap in micro butt laser welding with a pulsed laser beam

  5. Monogenetic volcanoes fed by interconnected dikes and sills in the Hopi Buttes volcanic field, Navajo Nation, USA

    Science.gov (United States)

    Muirhead, James D.; Van Eaton, Alexa R.; Re, Giuseppe; White, James D. L.; Ort, Michael H.

    2016-01-01

    Although monogenetic volcanic fields pose hazards to major cities worldwide, their shallow magma feeders (networks. Analysis of vent alignments using the pyroclastic massifs and other eruptive centers (e.g., maar-diatremes) shows a NW-SE trend, parallel to that of dikes in the region. We therefore infer that dikes fed many of the eruptions. Dikes are also observed in places transforming to transgressive (ramping) sills. Estimates of the observable volume of dikes (maximum volume of 1.90 × 106 m3) and sills (minimum volume of 8.47 × 105 m3) in this study reveal that sills at Hopi Buttes make up at least 30 % of the shallow intruded volume (∼2.75 × 106 m3 total) within 350 m of the paeosurface. We have also identified saucer-shaped sills, which are not traditionally associated with monogenetic volcanic fields. Our study demonstrates that shallow feeders in monogenetic fields can form geometrically complex networks, particularly those intruding poorly consolidated sedimentary rocks. We conclude that the Hopi Buttes eruptions were primarily fed by NW-SE-striking dikes. However, saucer-shaped sills also played an important role in modulating eruptions by transporting magma toward and away from eruptive conduits. Sill development could have been accompanied by surface uplifts on the order of decimeters. We infer that the characteristic feeder systems described here for the Hopi Buttes may underlie monogenetic fields elsewhere, particularly where magma intersects shallow, and often weak, sedimentary rocks. Results from this study support growing evidence of the important role of shallow sills in active monogenetic fields.

  6. Sentinel nodes identified by computed tomography-lymphography accurately stage the axilla in patients with breast cancer

    International Nuclear Information System (INIS)

    Motomura, Kazuyoshi; Sumino, Hiroshi; Noguchi, Atsushi; Horinouchi, Takashi; Nakanishi, Katsuyuki

    2013-01-01

    Sentinel node biopsy often results in the identification and removal of multiple nodes as sentinel nodes, although most of these nodes could be non-sentinel nodes. This study investigated whether computed tomography-lymphography (CT-LG) can distinguish sentinel nodes from non-sentinel nodes and whether sentinel nodes identified by CT-LG can accurately stage the axilla in patients with breast cancer. This study included 184 patients with breast cancer and clinically negative nodes. Contrast agent was injected interstitially. The location of sentinel nodes was marked on the skin surface using a CT laser light navigator system. Lymph nodes located just under the marks were first removed as sentinel nodes. Then, all dyed nodes or all hot nodes were removed. The mean number of sentinel nodes identified by CT-LG was significantly lower than that of dyed and/or hot nodes removed (1.1 vs 1.8, p <0.0001). Twenty-three (12.5%) patients had ≥2 sentinel nodes identified by CT-LG removed, whereas 94 (51.1%) of patients had ≥2 dyed and/or hot nodes removed (p <0.0001). Pathological evaluation demonstrated that 47 (25.5%) of 184 patients had metastasis to at least one node. All 47 patients demonstrated metastases to at least one of the sentinel nodes identified by CT-LG. CT-LG can distinguish sentinel nodes from non-sentinel nodes, and sentinel nodes identified by CT-LG can accurately stage the axilla in patients with breast cancer. Successful identification of sentinel nodes using CT-LG may facilitate image-based diagnosis of metastasis, possibly leading to the omission of sentinel node biopsy

  7. Butt pressure welding of wheels from vehicles consisting of steel and aluminium; Pressstumpfschweissen von Fahrzeugraedern aus Stahl und Aluminium

    Energy Technology Data Exchange (ETDEWEB)

    Grobelin, K. [Hess Engineering AG, Frauenfeld (Switzerland)

    2001-07-01

    Every year in Europe 35 million wheels for vehicles are produced. Most of them are wheels consisting of metal tapes, both of steel and of aluminium alloys. The manufacturing of wheels is explained, in detail the method known as DC upset welding used for butt joints of wheel-rims. The engaged machinery, the specials of welding various materials, the limits of the method, and the quality assurance are discussed. Advantages of the applied method are joints of first-class quality, high productivity, energy saving and environmental cleanness. (orig.)

  8. Control of Precambrian basement deformation zones on emplacement of the Laramide Boulder batholith and Butte mining district, Montana, United States

    Science.gov (United States)

    Berger, Byron R.; Hildenbrand, Thomas G.; O'Neill, J. Michael

    2011-01-01

    What are the roles of deep Precambrian basement deformation zones in the localization of subsequent shallow-crustal deformation zones and magmas? The Paleoproterozoic Great Falls tectonic zone and its included Boulder batholith (Montana, United States) provide an opportunity to examine the importance of inherited deformation fabrics in batholith emplacement and the localization of magmatic-hydrothermal mineral deposits. Northeast-trending deformation fabrics predominate in the Great Falls tectonic zone, which formed during the suturing of Paleoproterozoic and Archean cratonic masses approximately 1,800 mega-annum (Ma). Subsequent Mesoproterozoic to Neoproterozoic deformation fabrics trend northwest. Following Paleozoic through Early Cretaceous sedimentation, a Late Cretaceous fold-and-thrust belt with associated strike-slip faulting developed across the region, wherein some Proterozoic faults localized thrust faulting, while others were reactivated as strike-slip faults. The 81- to 76-Ma Boulder batholith was emplaced along the reactivated central Paleoproterozoic suture in the Great Falls tectonic zone. Early-stage Boulder batholith plutons were emplaced concurrent with east-directed thrust faulting and localized primarily by northwest-trending strike-slip and related faults. The late-stage Butte Quartz Monzonite pluton was localized in a northeast-trending pull-apart structure that formed behind the active thrust front and is axially symmetric across the underlying northeast-striking Paleoproterozoic fault zone, interpreted as a crustal suture. The modeling of potential-field geophysical data indicates that pull-apart?stage magmas fed into the structure through two funnel-shaped zones beneath the batholith. Renewed magmatic activity in the southern feeder from 66 to 64 Ma led to the formation of two small porphyry-style copper-molybdenum deposits and ensuing world-class polymetallic copper- and silver-bearing veins in the Butte mining district. Vein orientations

  9. 3-D Characteristics of the Residual Stress in the Plate Butt Weld Between SA508 and F316L SS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyoung Soo; Kim, Tae Ryong [Korea Electric Power Research Institute, Daejeon (Korea, Republic of); Park, Jai Hak [Chungbuk National University, Cheongju (Korea, Republic of); Kim, Man Won [GNEC, Daejeon (Korea, Republic of); Cho, Seon Yeong [KLES, Daejeon (Korea, Republic of)

    2009-04-15

    This study is performed to check the three dimensional characteristics of residual stress in the dissimilar metal weld. Although two dimensional analysis has been widely used for the assessment of weld residual stress, it has limitations to understand the stress distribution of the third direction. 3-D analysis was done to understand residual stress distribution of the welded plate. A simple butt-welded plate was considered to show the stress variation on all direction. A mock-up plate weldment was fabricated with SA-508 and F316L, which are widely used in nuclear power plants. The analysis results were validated with the measured values in the mock-up.

  10. Integrated FEM-DBEM simulation of crack propagation in AA2024-T3 FSW butt joints considering manufacturing effects

    DEFF Research Database (Denmark)

    Sonne, Mads Rostgaard; Carlone, P.; Citarella, R.

    2015-01-01

    This paper deals with a numerical and experimental investigation on the influence of residual stresses on fatigue crack growth in AA2024-T3 friction stir welded butt joints. An integrated FEM-DBEM procedure for the simulation of crack propagation is proposed and discussed. A numerical FEM model...... of the welding process of precipitation hardenable AA2024-T3 aluminum alloy is employed to infer the process induced residual stress field. The reliability of the FEM simulations with respect to the induced residual stresses is assessed comparing numerical outcomes with experimental data obtained by means...

  11.  Ischemic Stroke Secondary to Aortic Dissection Following Rifle Butt Recoil Chest Injury: A Case Report

    Directory of Open Access Journals (Sweden)

    John Valiath

    2011-11-01

    Full Text Available  Ischemic stroke secondary to aortic dissection is not uncommon. We present a patient with left hemiplegia secondary to Stanford type A aortic dissection extending to the supra-aortic vessels, which was precipitated by rifle butt recoil chest injury. The diagnosis of aortic dissection was delayed due to various factors. Finally, the patient underwent successful Bentall procedure with complete resolution of symptoms. This case emphasizes the need for caution in the use of firearms for recreation and to take precautions in preventing such incidents. In addition, this case illustrates the need for prompt cardiovascular physical examination in patients presenting with stroke.

  12. Tool material effect on the friction stir butt welding of AA2124-T4 Alloy Matrix MMC

    Directory of Open Access Journals (Sweden)

    Yahya Bozkurt

    2018-01-01

    Full Text Available The purpose of the present work is to study on the effect of material properties tool on friction stir butt welding of AA2124-T4 alloy matrix MMC. Uncoated tool, coated tool with a CrN, and coated tool with AlTiN were used to weld aluminum MMC plates. Macrostructure and microstructure observations, ultimate tensile strength, wear resistance, and chemical analysis were carried out to determine the appropriate tool for joining these composite plates. Results showed that the good welded joints could be obtained when a tool is coated with AlTiN.

  13. Development of radiolabeled mannose-dextran conjugates for sentinel lymph node detection

    International Nuclear Information System (INIS)

    Fernandez Nunez, Eutimio Gustavo

    2011-01-01

    Early diagnosis of tumors and metastasis is the current cornerstone in public health policies directed towards the fights against cancer. In breast cancer and melanoma, the sentinel lymph node biopsy has been widely used for diagnoses of metastasis. The minor impact in patient of this technique compared with total nodes dissection and the accurate definition of therapeutic strategies have powered its spreading. The aim of this work was the development of radiolabeled dextran-mannose conjugates for diagnosis using the stable technetium core [ 99m Tc(CO)3] + . Cysteine, a trident ligand, was attached to the conjugates backbone, as a chelate for 99m Tc labeling. Radiolabeling conditions established for all products considered in this study showed high radiochemical purities (> 90%) and specific activities (>59,9 MBq/nmol) as well and high stability obtained through in vitro tests. The lymphatic node uptake increased significantly (4-folds) when mannose units were added to the conjugates compared with those without this monosaccharide. The radiolabeled cysteine-mannose-dextran conjugate with 30 kDa ( 99m Tc - DCM2) showed the best performance at different injected activities among the studied tracers. Concentrations of this radio complex higher than 1 M demonstrated an improvement of lymph node uptakes. Comparisons of 99m Tc - DCM2 performance with commercial radiopharmaceuticals in Brazil market for lymph node detection showed its upper profile. (author)

  14. U.S. Geological Survey distribution of European Space Agency's Sentinel-2 data

    Science.gov (United States)

    Pieschke, Renee L.

    2017-03-31

    A partnership established between the European Space Agency (ESA) and the U.S. Geological Survey (USGS) allows for USGS storage and redistribution of images acquired by the MultiSpectral Instrument (MSI) on the European Union's Sentinel-2 satellite mission. The MSI data are acquired from a pair of satellites, Sentinel-2A and Sentinel-2B, which are part of a larger set of ESA missions focusing on different aspects of Earth observation. The primary purpose of the Sentinel-2 series is to collect multispectral imagery over the Earth’s land surfaces, large islands, and inland and coastal waters. Sentinel-2A was launched in 2015 and Sentinel-2B launched in 2017.The collaborative effort between ESA and USGS provides for public access and redistribution of global acquisitions of Sentinel-2 data at no cost, which allows users to download the MSI imagery from USGS access systems such as Earth- Explorer, in addition to the ESA Sentinels Scientific Data Hub. The MSI sensor acquires 13 spectral bands that are highly complementary to data acquired by the USGS Landsat 8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+). The product options from USGS include a Full-Resolution Browse (FRB) image product generated by USGS, along with a 100-kilometer (km) by 100-km tile-based Level-1C top-of-atmosphere (TOA) reflectance product that is very similar (but not identical) to the currently (2017) distributed ESA Level 1C product.

  15. Implications of a positive sentinel node in oral squamous cell carcinoma

    DEFF Research Database (Denmark)

    Gurney, Benjamin A S; Schilling, Clare; Putcha, Venkata

    2012-01-01

    BACKGROUND: The role of sentinel node biopsy in head and neck cancer is currently being explored. Patients with positive sentinel nodes were investigated to establish if additional metastases were present in the neck, their distribution, and their impact on outcome. METHODS: In all, 109 patients ...

  16. Diagnosis the metastatic sentinel node with Tc-99m-MIBI

    International Nuclear Information System (INIS)

    Georgiev-Predic, M.; Predic, P.; Karner, I.; Dodig, D.

    2002-01-01

    Aim: The purpose of this study was to analyse the occurrence of visualisation malignancy of sentinel node during preoperative lymphoscintigraphy in breast cancer. To precisely diagnose the metastatic sentinel node is very difficult. Material and Methods:Preoperative lymphoscintigraphy was performed in 47 patients with breast cancer after injection of Tc-99m-MIBI. We injected 20-40 MBq Tc-99m-MIBI peritumoral. Anterior and prone lateral planar images were obtained 2h, 4h, 6h and 20h after injection. The uptake were in region of sentinel node calculed. The sentinel node was intraoperatively identified and histologically analysed. Results: In 27 patients with intraoperatively detected metastatic sentinel node was in 25 patients increased uptake in sentinel node on scintigrams after 20h detected. In 20 patients with intraoperatively non detected metastatic sentinel node was in 19 patients increased uptake on scintigrams ower 2h-6h detected. Conclusion: The results indicated that is lymphoscintigraphy with Tc-99m-MIBI is a new method for detection the preoperatively metastatic sentinel node

  17. Knowing what we breathe: Sentinel 4: a geostationary imaging UVN spectrometer for air quality monitoring

    Science.gov (United States)

    Bazalgette Courrèges-Lacoste, G.; Sallusti, M.; Bulsa, G.; Bagnasco, G.; Gulde, S.; Kolm, M. G.; Smith, D. J.; Maurer, R.

    2017-09-01

    Sentinel-4 is an imaging UVN (UV-VIS-NIR) spectrometer, developed by Airbus DS under ESA contract in the frame of the joint EU/ESA COPERNICUS program. The mission objective is the operational monitoring of trace gas concentrations for atmospheric chemistry and climate applications - hence the motto of Sentinel-4 "Knowing what we breathe".

  18. Sentinel lymph node procedure is highly accurate in squamous cell carcinoma of the vulva

    NARCIS (Netherlands)

    de Hullu, JA; Hollema, H; Piers, DA; Verheijen, RHM; van Diest, PJ; Mourits, MJE; Aalders, JG; van der Zee, AGJ

    Purpose: To determine the diagnostic accuracy of the sentinel lymph node procedure in patients with squamous cell carcinoma of the vulva and to investigate whether step sectioning and immunohistochemistry of sentinel lymph nodes increase the sensitivity for detection of metastases. Patients and

  19. Organized nation-wide implementation of sentinel lymph node biopsy in Denmark

    DEFF Research Database (Denmark)

    Friis, E.; Galatius, H.; Garne, J.P.

    2008-01-01

    they could include patients into the study. As a result of this strategy the sentinel lymph node staging was fully implemented in all Danish surgical breast cancer centres within three years and all sentinel node biopsies in the period were recorded in the DBCG data centre. Furthermore, the strategy...

  20. Factors influencing sentinel lymph node identification failure in breast cancer surgery

    DEFF Research Database (Denmark)

    Straalman, K.; Kristoffersen, U.S.; Galatius, H.

    2008-01-01

    The purpose of this study was to investigate potential risk factors for failed sentinel lymph node identification in breast cancer surgery. Patient characteristics, tumour characteristics, surgeon experience and detection success/failure were registered at 748 sentinel lymph node biopsy procedures...... at our inpatient clinic. Data were analysed with backward stepwise multiple logistic regression with a cut-off point of p

  1. The role of sentinel node detection techniques in vulvar and cervival cancer

    International Nuclear Information System (INIS)

    Wydra, D.; Sawicki, S.; Emerich, J.; Romanowicz, G.

    2002-01-01

    The sentinel node is the first lymph node that receives the lymph drainage from the primary tumour. The pathological status of the sentinel node should reflect the histopathology of the entire regional lymph drainage area - both vulvar and cervical cancer spread through the lymphatic system. In gynaecological oncology recent studies have confirmed the utility of the sentinel node concept in vulvar and cervical cancer. Three techniques for sentinel node localisation are available. The preoperative lymphoscintigraphy and intraoperative handheld gamma probe detection require the administration of the technetium-99m-labelled colloid around the tumour. The other method is based on the injection of the patent blue dye - during the surgery of the sentinel node because of the dye uptake becomes visible. Following detection, the sentinel lymph node can be removed separately and assessed with ultrastaging and immunohistochemical staining. In the early stages of vulvar and cervical cancer the lymph nodes metastases rate is relatively low - in most cases lymphadenectomy is not necessary. The determination of the regional lymph nodes' pathological status may limit the extent of the surgical treatment. The sentinel node detection rate is relatively high and depends on the applied technique. This technique may play an important role in the treatment of vulvar and cervical cancer. This paper describes the details of sentinel node identification and reviews the literature. (author)

  2. EANM practice guidelines for lymphoscintigraphy and sentinel lymph node biopsy in melanoma

    DEFF Research Database (Denmark)

    Bluemel, Christina; Herrmann, Ken; Giammarile, Francesco

    2015-01-01

    PURPOSE: Sentinel lymph node biopsy is an essential staging tool in patients with clinically localized melanoma. The harvesting of a sentinel lymph node entails a sequence of procedures with participation of specialists in nuclear medicine, radiology, surgery and pathology. The aim of this docume...

  3. Improving staging accuracy in colon and rectal cancer by sentinel lymph node mapping: A comparative study

    NARCIS (Netherlands)

    van der Zaag, E. S.; Buskens, C. J.; Kooij, N.; Akol, H.; Peters, H. M.; Bouma, W. H.; Bemelman, W. A.

    2009-01-01

    Aim: To compare the predictive value of sentinel lymph node (SN) mapping between patients with colon and rectal cancer. Patients and methods: An ex vivo SN procedure was performed in 100 patients with colon and 32 patients with rectal cancer. If the sentinel node was negative, immunohistochemical

  4. Citrullus lanatus `Sentinel' (Watermelon) Extract Reduces Atherosclerosis in LDL Receptor Deficient Mice

    Science.gov (United States)

    Poduri, Aruna; Rateri, Debra L.; Saha, Shubin K.; Saha, Sibu; Daugherty, Alan

    2012-01-01

    Watermelon (Citrullus lanatus or C. lanatus) has many potentially bioactive compounds including citrulline, which may influence atherosclerosis. In this study, we determined the effects of C. lanatus, provided as an extract of the cultivar `sentinel', on hypercholesterolemia-induced atherosclerosis in mice. Male LDL receptor deficient mice at 8 weeks old were given either C. lanatus `sentinel' extract (2% vol/vol; n=10) or a mixture of matching carbohydrates (2% vol/vol; n=8) as the control in drinking water, while fed a saturated fat-enriched diet for 12 weeks ad libitum. Mice consuming C. lanatus `sentinel' extract had significantly increased plasma citrulline concentrations. Systolic blood pressure was comparable between the two groups. Consumption of C. lanatus `sentinel' extract led to lower body weight and fat mass without influencing lean mass. There were no differences in food and water intake, and urine output between the two groups. C. lanatus `sentinel' extract administration decreased plasma cholesterol concentrations that were attributed to reductions of intermediate/low density lipoprotein cholesterol. Plasma concentrations of MCP-1 and IFN-γ were decreased and IL-10 increased in mice consuming C. lanatus `sentinel' extract. Intake of C. lanatus `sentinel' extract resulted in reductions of atherosclerosis in both aortic arch and thoracic regions. In conclusion, consumption of C. lanatus `sentinel' extract led to reduced body weight gain, decreased plasma cholesterol concentrations, improved homeostasis of pro- and anti-inflammatory cytokines, and attenuated development of atherosclerosis without affecting systolic blood pressure in hypercholesterolemic mice. PMID:22902326

  5. Completion Dissection or Observation for Sentinel-Node Metastasis in Melanoma

    NARCIS (Netherlands)

    Faries, M. B.; Thompson, J. F.; Cochran, A. J.; Andtbacka, R. H.; Mozzillo, N; Zager, Jonathan S.; Jahkola, T.; Bowles, T. L.; Testori, Alessandro; Beitsch, P. D.; Hoekstra, H. J.; Moncrieff, M.; Ingvar, C.; Wouters, M. W. J. M.; Sabel, M. S.; Levine, E. A.; Agnese, D.; Henderson, M.; Dummer, R; Rossi, C. R.; Neves, R. I.; Trocha, S. D.; Wright, Sara F.; Byrd, D. R.; Matter, M.; Hsueh, E.; MacKenzie-Ross, A.; Johnson, B. D.; Terheyden, P.; Berger, A. C.; Huston, T. L.; Wayne, J. D.; Smithers, B. Mark; Neuman, H. B.; Schneebaum, S.; Gershenwald, Jeffrey E.; Ariyan, C. E.; Desai, D. C.; Jacobs, L.; McMasters, K. M.; Gesierich, A.; Hersey, P.; Bines, S. D.; Kane, Michael J.; Barth, R. J.; McKinnon, J. G.; Farma, J. M.; Schultz, B. E.; Vidal-Sicart, S.; Hoefer, R. A.; Lewis, David J. M.; Scheri, R.; Kelley, M. C.; Nieweg, O. E.; Noyes, R. D.; Hoon, D. S. B.; Wang, H. -J.; Elashoff, D. A.; Elashoff, R. M.

    2017-01-01

    BACKGROUND Sentinel-lymph-node biopsy is associated with increased melanoma-specific survival (i.e., survival until death from melanoma) among patients with node-positive intermediate-thickness melanomas (1.2 to 3.5 mm). The value of completion lymph-node dissection for patients with sentinel-node

  6. Stress Distribution in the Dissimilar Metal Butt Weld of Nuclear Reactor Piping due to the Simulation Technique for the Repair Welding

    International Nuclear Information System (INIS)

    Lee, Hweeseung; Huh, Namsu; Kim, Jinsu; Lee, Jinho

    2013-01-01

    During welding, the dissimilar metal butt welds of nuclear piping are typically subjected to repair welding in order to eliminate defects that are found during post-weld inspection. It has been found that the repair weld can significantly increase the tensile residual stress in the weldment, and therefore, accurate estimation of the weld residual stress due to repair weld, especially for dissimilar metal welds using Ni-based alloy 82/182 in nuclear components, is of great importance in order to assess susceptibility to primary water stress corrosion cracking. In the present study, the stress distributions of dissimilar metal butt welds in nuclear reactor piping subjected to repair weld were investigated based on detailed nonlinear finite element analyses. Particular emphasis was placed on the variation of the stress distribution in the dissimilar metal butt weld according to the finite element welding analysis sequence for the repair welding process

  7. Ex vivo sentinel lymph node investigation in colorectal cancer

    Directory of Open Access Journals (Sweden)

    Antônio Hilário Alves Freitas

    2013-01-01

    Full Text Available Introduction: In Brazil, about 26,000 cases of colorectal cancer are diagnosed per year. Pa- tients considered at the early stage of disease (without lymph node evolve with tumor relapse or recurrence in up to a quarter of cases, probably due to understaging. Objective: Research on ex vivo sentinel lymph node in patients with colorectal adenocarcinoma. Materials and methods: We studied 37 patients who underwent curative surgical resection. The marker used to identify lymph nodes was patent blue dye injected into the peritu- moral submucosa of the open surgical specimen immediately after its removal from the abdominal cavity. Results: Ex vivo identification of sentinel lymph node with marker occurred in 13 (35.1% patients. The sensitivity was 40% and 60% false negative. The detailed histological examina- tion of sentinel lymph nodes with multilevel section and immunohistochemistry showed metastasis in one (4.3% individual, considered ultra-staging. Conclusion: The ex vivo identification of sentinel lymph node had questionable benefits, and worse results when include patients with rectal cancer. Restaging of one patient was possible after multilevel section and immunohistochemistry of the sentinel lymph node, but more research is needed to evaluate the role of micrometastases in patients with colorectal cancer. Resumo: Introdução: No Brasil, a cada ano são diagnosticados cerca de 26.000 casos de câncer colorre- tal. Pacientes com estadiamento considerado inicial, sem linfonodo metastático, evoluem com recorrência ou recidiva do tumor em até um quarto dos casos, por provável subesta- diamento. Objetivo: pesquisar sobre linfonodo-sentinela ex vivo em pacientes com adeno- carcinoma colorretal. Objetivo: Foram estudados 37 pacientes, submetidos à cirurgia oncológica com ressecção caráter curativo. O marcador de linfonodos utilizado foi o corante azul patente, injetado na submucosa peritumoral da peça cirúrgica aberta imediatamente

  8. SENTINEL-2 Level 1 Products and Image Processing Performances

    Science.gov (United States)

    Baillarin, S. J.; Meygret, A.; Dechoz, C.; Petrucci, B.; Lacherade, S.; Tremas, T.; Isola, C.; Martimort, P.; Spoto, F.

    2012-07-01

    In partnership with the European Commission and in the frame of the Global Monitoring for Environment and Security (GMES) program, the European Space Agency (ESA) is developing the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. While ensuring data continuity of former SPOT and LANDSAT multi-spectral missions, Sentinel-2 will also offer wide improvements such as a unique combination of global coverage with a wide field of view (290 km), a high revisit (5 days with two satellites), a high resolution (10 m, 20 m and 60 m) and multi-spectral imagery (13 spectral bands in visible and shortwave infra-red domains). In this context, the Centre National d'Etudes Spatiales (CNES) supports ESA to define the system image products and to prototype the relevant image processing techniques. This paper offers, first, an overview of the Sentinel-2 system and then, introduces the image products delivered by the ground processing: the Level-0 and Level-1A are system products which correspond to respectively raw compressed and uncompressed data (limited to internal calibration purposes), the Level-1B is the first public product: it comprises radiometric corrections (dark signal, pixels response non uniformity, crosstalk, defective pixels, restoration, and binning for 60 m bands); and an enhanced physical geometric model appended to the product but not applied, the Level-1C provides ortho-rectified top of atmosphere reflectance with a sub-pixel multi-spectral and multi-date registration; a cloud and land/water mask is associated to the product. Note that the cloud mask also provides an indication about cirrus. The ground sampling distance of Level-1C product will be 10 m, 20 m or 60 m according to the band. The final Level-1C product is tiled following a pre-defined grid of 100x100 km2, based on UTM/WGS84 reference frame. The

  9. SENTINEL-2 LEVEL 1 PRODUCTS AND IMAGE PROCESSING PERFORMANCES

    Directory of Open Access Journals (Sweden)

    S. J. Baillarin

    2012-07-01

    Full Text Available In partnership with the European Commission and in the frame of the Global Monitoring for Environment and Security (GMES program, the European Space Agency (ESA is developing the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. While ensuring data continuity of former SPOT and LANDSAT multi-spectral missions, Sentinel-2 will also offer wide improvements such as a unique combination of global coverage with a wide field of view (290 km, a high revisit (5 days with two satellites, a high resolution (10 m, 20 m and 60 m and multi-spectral imagery (13 spectral bands in visible and shortwave infra-red domains. In this context, the Centre National d'Etudes Spatiales (CNES supports ESA to define the system image products and to prototype the relevant image processing techniques. This paper offers, first, an overview of the Sentinel-2 system and then, introduces the image products delivered by the ground processing: the Level-0 and Level-1A are system products which correspond to respectively raw compressed and uncompressed data (limited to internal calibration purposes, the Level-1B is the first public product: it comprises radiometric corrections (dark signal, pixels response non uniformity, crosstalk, defective pixels, restoration, and binning for 60 m bands; and an enhanced physical geometric model appended to the product but not applied, the Level-1C provides ortho-rectified top of atmosphere reflectance with a sub-pixel multi-spectral and multi-date registration; a cloud and land/water mask is associated to the product. Note that the cloud mask also provides an indication about cirrus. The ground sampling distance of Level-1C product will be 10 m, 20 m or 60 m according to the band. The final Level-1C product is tiled following a pre-defined grid of 100x100 km2, based on UTM/WGS84 reference frame

  10. Validation of Hotspots Detected by Satellites in Sentinel Asia

    Science.gov (United States)

    Kaku, K.; Kushida, K.; Fukuda, M.

    2008-12-01

    The Sentinel Asia (SA) initiative is a collaboration between space agencies and disaster management agencies, applying remote sensing and Web-GIS technologies to assist disaster management in the Asia- Pacific region. It aims to: "EImprove safety in society by ICT and space technology "EImprove speed and accuracy of disaster preparedness and early warning "EMinimize the number of victims and social/economic losses. SA is a voluntary initiative led by the Asia-Pacific Regional Space Agency Forum (APRSAF) to share disaster information in near-real-time across the Asia-Pacific region. Wildfire is a major and recurring phenomenon that has a serious impact on property and human health, affecting many countries in the Asia region. Compared to other disasters in the area, it does not necessarily cause many immediate fatalities. However, it causes serious impact on property and human health due to smoke. Furthermore, its effects are of great relevance both at a regional and global level, and accordingly bear substantial influence on global warming. Responding to requirements from Asian countries, under Sentinel Asia a dedicated Wildfire Working Group (WG) has been established to apply remote sensing technology to the management of wildfire. Having accurate information on the location and intensity of the fires, and subsequent control of wildfire, are therefore very important and urgent tasks across the region. SA primarily addresses the issue of near-real-time information distribution on wildfires in the region. Concerning hotspot data obtained by satellites, it is essential to validate and improve its accuracy. In the framework of Sentinel Asia Wildfire WG, various approaches to hotspot detection, including MOD14 algorithm for MODIS hotspots, were studied, and their validations were carried out, comparing them with active fires extracted from satellite imagery and ground truth data in Chiengmai, Thailand and in Kalimantan, Indonesia.

  11. Harmonized Landsat/Sentinel-2 Reflectance Products for Land Monitoring

    Science.gov (United States)

    Masek, J. G.; Ju, J.; Claverie, M.; Vermote, E.; Dungan, J. L.; Roger, J. C.; Skakun, S.; Justice, C. O.

    2017-12-01

    Many land applications require more frequent observations than can be obtained from a single "Landsat class" sensor. Agricultural monitoring, inland water quality assessment, stand-scale phenology, and numerous other applications all require near-daily imagery at better than 1ha resolution. Thus the land science community has begun expressing a desire for a "30-meter MODIS" global monitoring capability. One cost-effective way to achieve this goal is via merging data from multiple, international observatories into a single virtual constellation. The Harmonized Landsat/Sentinel-2 (HLS) project has been working to generate a seamless surface reflectance product by combining observations from USGS/NASA Landsat-8 and ESA Sentinel-2. Harmonization in this context requires a series of radiometric and geometric transforms to create a single surface reflectance time series agnostic to sensor origin. Radiometric corrections include a common atmospheric correction using the Landsat-8 LaSRC/6S approach, a simple BRDF adjustment to constant solar and nadir view angle, and spectral bandpass adjustments to fit the Landsat-8 OLI reference. Data are then resampled to a consistent 30m UTM grid, using the Sentinel-2 global tile system. Cloud and shadow masking are also implemented. Quality assurance (QA) involves comparison of the output 30m HLS products with near-simultaneous MODIS nadir-adjusted observations. Prototoype HLS products have been processed for 7% of the global land area using the NASA Earth Exchange (NEX) compute environment at NASA Ames, and can be downloaded from the HLS web site (https://hls.gsfc.nasa.gov). A wall-to-wall North America data set is being prepared for 2018.This talk will review the objectives and status of the HLS project, and illustrate applications of high-density optical time series data for agriculture and ecology. We also discuss lessons learned from HLS in the general context of implementing virtual constellations.

  12. Mass Processing of Sentinel-1 Images for Maritime Surveillance

    Directory of Open Access Journals (Sweden)

    Carlos Santamaria

    2017-07-01

    Full Text Available The free, full and open data policy of the EU’s Copernicus programme has vastly increased the amount of remotely sensed data available to both operational and research activities. However, this huge amount of data calls for new ways of accessing and processing such “big data”. This paper focuses on the use of Copernicus’s Sentinel-1 radar satellite for maritime surveillance. It presents a study in which ship positions have been automatically extracted from more than 11,500 Sentinel-1A images collected over the Mediterranean Sea, and compared with ship position reports from the Automatic Identification System (AIS. These images account for almost all the Sentinel-1A acquisitions taken over the area during the two-year period from the start of the operational phase in October 2014 until September 2016. A number of tools and platforms developed at the European Commission’s Joint Research Centre (JRC that have been used in the study are described in the paper. They are: (1 Search for Unidentified Maritime Objects (SUMO, a tool for ship detection in Synthetic Aperture Radar (SAR images; (2 the JRC Earth Observation Data and Processing Platform (JEODPP, a platform for efficient storage and processing of large amounts of satellite images; and (3 Blue Hub, a maritime surveillance GIS and data fusion platform. The paper presents the methodology and results of the study, giving insights into the new maritime surveillance knowledge that can be gained by analysing such a large dataset, and the lessons learnt in terms of handling and processing the big dataset.

  13. Busted Butte Phase 2: Analysis of Post-Test Mineback and Overcore Rock Samples

    International Nuclear Information System (INIS)

    Turin, H.J.; McGraw, M.A.; Jones, C.L.; Scism, C.D.; Soll, W.E.

    2002-01-01

    A complex tracer mixture was injected continuously for over two years into a 10 x 10 x 7 m block of tuff as part of the unsaturated-zone (UZ) tracer test at Busted Butte. The test was designed to address uncertainties associated with flow and transport models within the Topopah Springs and Calico Hills tuffs. The tracer mixture included nonreactive (Br, I, and FBAs) and reactive tracers (Li, Ce, Sm, Ni, Coy and Mn) and synthetic colloids. Once injection was completed, samples from the block were collected in two ways. Overcores were taken from around and below injection holes. Then, the entire block was excavated via mineback--during which progressive vertical planes of the block were exposed. Samples from the overcores and mineback were analyzed to determine the distribution of tracers on different spatial scales than available from collection borehole data. Rock analyses confirmed collection pad results that the nonreactive tracers, Br and FBAs, moved several meters. Furthermore, Br and FBAs are observed above and lateral to the injector planes suggesting that capillarity was an important process for tracer movement. Lithium, the most mobile of the metals, was transported on a scale of meters. This is consistent with laboratory sorption measurements and observed breakthrough on the collection pads. Co and Ni show transport distances of tens of cm, while Sm and Ce moved far less, possibly due to precipitation and sorption effects. Colloid transport was assessed using 1 ft3 blocks extracted from the BB Phase 2 block. In the Calico Hills material, after 15 L of water was injected over 3.5 months, less than 1% of the colloids injected were recovered. Flow patterns in the block indicate that water injected at the center imbibed outward from the injection point. In a block taken from a boundary of the Calico Hills ashfall layer, breakthrough was observed only due to fractures formed during drying of the block. The colloid transport module for FEHM was tested against

  14. Geologic map of the Strawberry Butte 7.5’ quadrangle, Meagher County, Montana

    Science.gov (United States)

    Reynolds, Mitchell W.; Brandt, Theodore R.

    2017-06-19

    The 7.5′ Strawberry Butte quadrangle in Meagher County, Montana near the southwest margin of the Little Belt Mountains, encompasses two sharply different geologic terranes.  The northern three-quarters of the quadrangle are underlain mainly by Paleoproterozoic granite gneiss, across which Middle Cambrian sedimentary rocks rest unconformably.  An ancestral valley of probable late Eocene age, eroded northwest across the granite gneiss terrane, is filled with Oligocene basalt and overlying Miocene and Oligocene sandstone, siltstone, tuffaceous siltstone, and conglomerate.  The southern quarter of the quadrangle is underlain principally by deformed Mesoproterozoic sedimentary rocks of the Newland Formation, which are intruded by Eocene biotite hornblende dacite dikes.  In this southern terrane, Tertiary strata are exposed only in a limited area near the southeast margin of the quadrangle.  The distinct terranes are juxtaposed along the Volcano Valley fault zone—a zone of recurrent crustal movement beginning possibly in Mesoproterozoic time and certainly established from Neoproterozoic–Early Cambrian to late Tertiary time.  Movement along the fault zone has included normal faulting, the southern terrane faulted down relative to the northern terrane, some reverse faulting as the southern terrane later moved up against the northern terrane, and lateral movement during which the southern terrane likely moved west relative to the northern terrane.  Near the eastern margin of the quadrangle, the Newland Formation is locally the host of stratabound sulfide mineralization adjacent to the fault zone; west along the fault zone across the remainder of the quadrangle are significant areas and bands of hematite and iron-silicate mineral concentrations related to apparent alteration of iron sulfides.  The map defines the distribution of a variety of surficial deposits, including the distribution of hematite-rich colluvium and iron-silicate boulders.  The southeast

  15. Busted Butte report on laboratory radionuclide migration experiments in non-welded tuff under unsaturated conditions

    Energy Technology Data Exchange (ETDEWEB)

    Vandergraaf, T.T.; Drew, D.J.; Ticknor, K.V

    2002-11-01

    Three blocks of non-welded tuff, one nominally one cubic foot (trial block) and the other two, nominally one cubic metre (1 m{sup 3}), were excavated from the Busted Butte Test Facility on the Nevada Test Site and transported to the Atomic Energy of Canada Limited Whiteshell Laboratories in Pinawa, Manitoba. The trial block and one of the 1-m{sup 3} blocks were used for unsaturated flow experiments. The remaining 1-m{sup 3} block is being used for saturated flow experiments and will be reported on separately. After a vertical flow of synthetic transport solution was set up under unsaturated conditions, a suite of conservative and chemically reactive radionuclide tracers was injected at volumetric flow rates of 20 mL/hr in the trial block, and 10 mL/hr in the 1-m{sup 3} block. The duration of the migration experiment in the trial block was 87 days, while the migration experiment in the 1-m{sup 3} block was continuing after 600 days. Results obtained from the migration experiment in the trial block showed that transport of {sup 95m+99}Tc, injected as the pertechnetate (an)ion, was slightly faster than that of the transport solution, using tritiated water ({sup 3}H{sub 2}O) as a flow indicator. Retardation of {sup 237}Np was consistent with that predicted from results obtained in supporting static batch sorption studies. Post-migration analysis of the flow field in the trial block showed that the front of the {sup 22}Na had migrated about half the distance through the block, and that {sup 60}Co and {sup 137}Cs had been retained near the inlet. This observation agrees qualitatively with that predicted from the results from static batch sorption studies. In the larger scale experiment, the transport behavior of Tc is very similar to that of the transport solution at this point in time. None of the other radionuclide tracers have been detected in water collected from this block. This observation is consistent with the observations for the smaller block. (author)

  16. CTC Sentinel. Volume 6, Issue 8, August 2013

    Science.gov (United States)

    2013-08-01

    future. Syria,” CTC Sentinel 6:8 (2013). 16 For some interesting work on this issue, see Thomas Hegghammer, “Should I Stay or Should I Go? Explain- ing...the late 1980s and early 1 Arie Perliger, “Democracy in an Ongoing Conflict: The Politics of Defence in Israel,” in James Forest and Isaiah Wilson...people of Syria and Iran…will not Hates Most, U.S. or Iran?” Bloomberg, February 5, 2013. 24 Thomas Erdbrink, “Khamenei: Iran Will Back ‘Any Nations

  17. [Utility and advantages of single tracer subareolar injection in sentinel lymph node biopsy in breast cancer].

    Science.gov (United States)

    Armas, Fayna; Hernández, María Jesús; Vega, Víctor; Gutiérrez, Isabel; Jiménez, Concepción; Pavcovich, Marta; Báez, Beatriz; Pérez-Correa, Pedro; Núñez, Valentín

    2005-10-01

    Sentinel lymph node (SLN) biopsy is a reliable technique for determining axillary status in patients with early breast cancer. This technique is a minimally invasive procedure that can avoid the use of lymphadenectomy in patients without axillary involvement. We present a validation study of SLN biopsy with subareolar injection of 99mTc-nanocolloids. We studied 100 patients with early breast cancer (T1 and T2) over a 2-year period. All patients underwent deep subareolar-injection of 99mTc-nanocoloid for localization of the sentinel node. Images were obtained and when the sentinel node was seen, it was marked on the skin. All patients underwent tumor excision and radioguided SLN biopsy followed by complete lymphadenectomy. Histopathological analysis of sentinel nodes was performed by hematoxylin-eosin and immunohistochemistry with cytokeratins. The sentinel node was identified in all patients, and a mean of 1.95 sentinel nodes per patient were found. Lymphatic metastases in the sentinel node were found in 44 patients and in 15 of these tumoral spread was also found in the remaining axillary nodes. In the 56 remaining patients the sentinel node was free of metastasis, but in two of them a non-sentinel node was found to be positive (4.5% false negative rate). Sensitivity was 95.7% (44/46), specificity was 100% (54/54), the positive predictive value was 100% and the negative predictive value was 96.4% (54/56). SLN biopsy is an accurate alternative to complete axillary lymph node dissection in patients with early-stage breast cancer. This technique improves the staging of these patients and decreases the morbidity associated with lymphadenectomy. The advantages of subareolar injection are that a single injection site is required, the tumor does not have to be located by other techniques, it allows rapid visualization of the sentinel node and avoids the "shine through phenomenon" when the tumor is located near the axilla.

  18. PENGARUH BESAR ARUS LISTRIK DENGAN MENGGUNAKAN ELEKTRODA SMAW TERHADAP KEKUATAN SAMBUNGAN LAS BUTT JOINT PADA PLAT MILD STEEL

    Directory of Open Access Journals (Sweden)

    Sarjito Jokosisworo

    2012-03-01

    Full Text Available The influence of mechanic disposition, is one of the factor influence ship strength. This influence can be test by mechanical test in welding butt joint. The result test database analysis can be conclude that very helpful to increase safety and quality butt joint. With steel specification C= 0,15%, Si= 0,24%, Mn= 0,88%,P= 0,018%, S= 0,034%. This material give a 90, 110, 125 ampere with SMAW AC electrode diameter 3,2 mm x 350 mm with V root and 600 angle In the fabrication of mild steel products, components or equipment, manufacturers employ welding as the principal joining method. Mild steel are weldable materials, and a welded joint can provide optimum corrosion resistance, strength, and fabrication economy. However, designers should recognize that any metal, including stainless steels, may undergo certain changes during welding. It is necessary, therefore, to exercise a reasonable degree of care during welding to minimize or prevent any deleterious effects that may occur, and to preserve the same degree of corrosion resistance and strength in weld zone that is an intheren part of the base metal

  19. Special metallurgy - the electrical butt-welding by flashing of sintered magnesium-magnesium oxide composites (1963)

    International Nuclear Information System (INIS)

    Charleux, J.

    1963-01-01

    Electrical resistance welding has become quite important since World War II because of the need of a high yield in aeronautical production. Progress has been due in particular to the improvements made in electronically controlled apparatus making possible the automatic control of welding. For the butt-welding of sections requiring either a high production rate or a high quality weld, the flash butt-welding system has been very much developed these last few years. The use of this welding method is of great importance in the field of the bonding of oxidisable metals such as magnesium or aluminium and its alloys, because the welded joint is free from oxides. This study consists of general considerations on the flash-welding process with regard to temperature distribution in the parts during welding, and to electrical phenomena connected with flashing. Besides this general or theoretical section, we have applied the welding process to the bonding of sintered magnesium, a magnesium-magnesium oxide composite, whose use as a structural element in nuclear reactors is considered. (author) [fr

  20. Upper Gastrointestinal (GI) Series

    Science.gov (United States)

    ... standard barium upper GI series, which uses only barium a double-contrast upper GI series, which uses both air and ... evenly coat your upper GI tract with the barium. If you are having a double-contrast study, you will swallow gas-forming crystals that ...

  1. Is the HIV sentinel surveillance system adequate in China? Findings from an evaluation of the national HIV sentinel surveillance system

    Directory of Open Access Journals (Sweden)

    Marc Bulterys

    2012-11-01

    Full Text Available Background: An external evaluation was conducted to assess the performance of the national HIV sentinel surveillance system (HSS, identify operational challenges at national and local levels and provide recommendations for improvement.Methods: The United States Centers for Disease Control and Prevention’s (CDC Updated Guidelines for Evaluating Public Health Surveillance Systems were followed to assess the key attributes of HSS. Comprehensive assessment activities were conducted, including: using a detailed checklist to review surveillance guidelines, protocols and relevant documents; conducting self-administered, anonymous surveys with 286 local China CDC staff; and carrying out field observations in 32 sentinel sites in four provinces.Results: China has built an extensive HSS with 1888 sentinel sites to monitor HIV epidemic trends by population groups over time. The strengths of HSS lie in its flexibility, simplicity, usefulness and increase in coverage in locations and populations. With its rapid expansion in 2010, HSS faces challenges in maintaining acceptability, timeliness, data quality, representativeness and sustainability.Recommendations: Implementation of the national guidelines should be standardized by strengthening training, monitoring and supervision of all staff involved, including community-based organizations. National surveillance guidelines need to be revised to strengthen data quality and representativeness, particularly to include specific instructions on HIV testing result provision, collection of identifying information, sample size and sampling methods particularly for men who have sex with men (MSM, collection of refusal information, and data interpretation. Sustainability of China’s HSS could be strengthened by applying locally tailored surveillance strategies, strengthening coordination and cooperation among government agencies and ensuring financial and human resources.

  2. Metal loading in Soda Butte Creek upstream of Yellowstone National Park, Montana and Wyoming; a retrospective analysis of previous research; and quantification of metal loading, August 1999

    Science.gov (United States)

    Boughton, G.K.

    2001-01-01

    Acid drainage from historic mining activities has affected the water quality and aquatic biota of Soda Butte Creek upstream of Yellowstone National Park. Numerous investigations focusing on metals contamination have been conducted in the Soda Butte Creek basin, but interpretations of how metals contamination is currently impacting Soda Butte Creek differ greatly. A retrospective analysis of previous research on metal loading in Soda Butte Creek was completed to provide summaries of studies pertinent to metal loading in Soda Butte Creek and to identify data gaps warranting further investigation. Identification and quantification of the sources of metal loading to Soda Butte Creek was recognized as a significant data gap. The McLaren Mine tailings impoundment and mill site has long been identified as a source of metals but its contribution relative to the total metal load entering Yellowstone National Park was unknown. A tracer-injection and synoptic-sampling study was designed to determine metal loads upstream of Yellowstone National Park.A tracer-injection and synoptic-sampling study was conducted on an 8,511-meter reach of Soda Butte Creek from upstream of the McLaren Mine tailings impoundment and mill site downstream to the Yellowstone National Park boundary in August 1999. Synoptic-sampling sites were selected to divide the creek into discrete segments. A lithium bromide tracer was injected continuously into Soda Butte Creek for 24.5 hours. Downstream dilution of the tracer and current-meter measurements were used to calculate the stream discharge. Stream discharge values, combined with constituent concentrations obtained by synoptic sampling, were used to quantify constituent loading in each segment of Soda Butte Creek.Loads were calculated for dissolved calcium, silica, and sulfate, as well as for dissolved and total-recoverable iron, aluminum, and manganese. Loads were not calculated for cadmium, copper, lead, and zinc because these elements were infrequently

  3. The importance of tattoo pigment in sentinel lymph nodes.

    Science.gov (United States)

    Soran, Atilla; Menekse, Ebru; Kanbour-Shakir, Amal; Tane, Kaori; Diego, Emilia; Bonaventura, Marguerite; Johnson, Ronald

    2017-01-01

    The presence of pigment in axillary lymph nodes (LN) secondary to migration of tattoo ink can imitate the appearance of a blue sentinel lymph node (SLN) on visual inspection, causing the operator to either miss the true SLN or excise more than is needed. We present patients with tattoos ipsilateral to an early stage breast cancer who underwent a SLN biopsy. Patients were retrospectively reviewed from medical records and clinicopathologic data was collected. A total of 52 LNs were retrieved from 15 patients for sentinel mapping and 29 of them had tattoo pigmentation on pathologic evaluation. Of those 29 SLNs, 2 of them (6.9%) were pigmented, but did not contain either blue dye or Tc-99m (pseudopigmented SLN). Two (3.8%) SLNs were positive for metastasis; both of these had either blue dye or Tc99m uptake, and 1 demonstrated tattoo pigment in the node. In this cohort of patients with ipsilateral tattoos, removed more LNs lead to unnecessary excision which may important for increasing the risk of arm morbidity from SLN biopsy. However, the presence of tattoo pigment did not interfere with understaging for axillary mapping and it did not effect of pathological identification of SLNs positivity.

  4. Water striders (family Gerridae): mercury sentinels in small freshwater ecosystems

    International Nuclear Information System (INIS)

    Jardine, Timothy D.; Al, Tom A.; MacQuarrie, Kerry T.B.; Ritchie, Charles D.; Arp, Paul A.; Maprani, Antu; Cunjak, Richard A.

    2005-01-01

    To circumvent some of the previous limitations associated with contaminant-monitoring programs, we tested the suitability of the water strider (Hemiptera: Gerridae) as a mercury sentinel by comparing total mercury concentrations in water striders and brook trout (Salvelinus fontinalis) from a variety of stream sites in New Brunswick, Canada. There was a strong association between the two variables across sites (r 2 = 0.81, P < 0.001) in systems where both atmospheric deposition and a point source (an abandoned gold mine) were likely contributing to ambient mercury levels. In a small stream draining the gold mine tailings pile, water striders had mercury concentrations an order of magnitude higher than those from reference locations. Temporal variation at three southern New Brunswick stream sites was non-significant. These results suggest that water strider mercury levels accurately quantify food chain entry of the element. The use of sentinel species holds great potential for expanding contaminant-monitoring programs. - Water striders accurately reflect the entry of mercury in food chains of small freshwater systems

  5. RICE CROP MAPPING USING SENTINEL-1A PHENOLOGICAL METRICS

    Directory of Open Access Journals (Sweden)

    C. F. Chen

    2016-06-01

    Full Text Available Rice is the most important food crop in Vietnam, providing food more than 90 million people and is considered as an essential source of income for majority of rural populations. Monitoring rice-growing areas is thus important to developing successful strategies for food security in the country. This paper aims to develop an approach for crop acreage estimation from multi-temporal Sentinel-1A data. We processed the data for two main cropping seasons (e.g., winter–spring, summer–autumn in the Mekong River Delta (MRD, Vietnam through three main steps: (1 data pre-processing, (3 rice classification based on crop phenological metrics, and (4 accuracy assessment of the mapping results. The classification results compared with the ground reference data indicated the overall accuracy of 86.2% and Kappa coefficient of 0.72. These results were reaffirmed by close correlation between the government’s rice area statistics for such crops (R2 > 0.95. The values of relative error in area obtained for the winter–spring and summer–autumn were -3.6% and 6.7%, respectively. This study demonstrates the potential application of multi-temporal Sentinel-1A data for rice crop mapping using information of crop phenology in the study region.

  6. US Domestic Cats as Sentinels for Perfluoroalkyl Substances ...

    Science.gov (United States)

    Perfluoroalkyl substances (PFAS), such as perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA) , are persistent, globally distributed, anthropogenic compounds. The primary source(s) for human exposure are not well understood although within home exposure is likely important since many consumer products have been treated with different PFAS, and people spend much of their lives indoors. Herein, domestic cats were used as sentinels to investigate potential exposure and health linkages. PFAS in serum samples of 72 pet and feral cats, including 11 healthy and 61 with one or more primary disease diagnoses, were quantitated using high-resolution time-of-flight mass spectroscopy. All but one sample had detectable PFAS, with PFOS and perfluorohexane sulfonate (PFHxS) ranging from PFAS prevalence and geometric means in cats were very similar to contemporary NHANES reports of human sera in the U. S. POPULATION: The highest PFAS serum concentrations detected were in indoor cats due to disproportionately elevated PFHxS levels. Ranked by quartile, contingency testing indicated that total PFAS levels were positively associated with living indoors and with higher body weight and body condition scores. Individual PFAS quartile rankings suggested positive associations with respiratory effusion, thyroid, liver, and possibly chronic kidney disease . Domestic cats appear to be useful sentinels for assessing primary

  7. Selective Sentinel Lymphadenectomy for Breast Cancer in the United States

    Directory of Open Access Journals (Sweden)

    Stanley P.L. Leong

    2004-10-01

    Full Text Available Lymph node status is the most reliable prognostic indicator for breast cancer patients. Sentinel lymph nodes (SLNs are the first draining lymph nodes for metastatic breast cancer to spread from the primary site. Although the therapeutic role of selective sentinel lymphadenectomy (SSL in breast cancer has not been determined, the practical significance is that it is being used as a staging procedure, so that a negative SLN can spare a patient more extensive axillary lymph node dissection (ALND with its associated morbidity. If the SLN is negative, the negative predictive value of the remaining nodal basin for breast cancer exceeds 95%. SSL selects out one or a few SLNs and permits more extensive study of the nodes by the pathologist. Such extensive examination would not be practical for the many nodes yielded by a standard ALND. SSL is rapidly evolving into a standard approach for staging primary breast cancer in the United States, without the maturation of results from clinical trials.

  8. Selective sentinel lymph node biopsy in male breast cancer.

    Science.gov (United States)

    Martin-Marcuartu, J J; Alvarez-Perez, R M; Sousa Vaquero, J M; Jimenez-Hoyuela García, J M

    To evaluate the reproducibility of the sentinel lymph node (SLN) technique in male breast cancer. We retrospectively analysed 21 male patients diagnosed with breast cancer in our hospital from 2008 to 2016 with, at least, 18 months follow-up. Fifteen patients underwent selective sentinel lymph node biopsy (SLNB) following the usual protocols with peritumoral injection of 18.5-111MBq of 99m Tc-nanocoloides and acquisition of planar images 2hours after the injection. In 2 cases it was necessary to perform a SPECT/CT to locate the SLN. Immunohistochemistry and molecular techniques (OSNA) were used for their analysis. Six patients did not undergo SLNB because they had pathological nodes or distant disease at the time of diagnosis. SLNB was performed in 15 patients. The SLN was negative in 6 patients and positive in the remaining 9. Three patients with positive SLNB did not need axillary lymphadenectomy because of the low number of copies by molecular analysis OSNA. Axillary lymphadenectomy was performed in the remaining 6 patients with the result of 4 positive axillary lymphadenectomies and 2 that did not show further extension of the disease. According to our experience, SLNB in males is a reproducible, useful, safe and reliable technique which avoids unnecessary axillary lymphadenectomy and prevents the appearance of undesirable effects. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  9. The 'Sentinel Node' Concept: More Questions Raised than Answers Provided?

    Science.gov (United States)

    Schlag

    1998-01-01

    preoperative lymph node staging. However, there is none. General criteria like size, shape, structure, or texture in variable imaging modalities are unreliable. While it is still too early to definitely evaluate in this context new diagnostic modalities like PET, immunoscintigraphy, or contrast-enhanced MRI, the initial results do not provoke clear enthusiasm toward the development of a sensitive and specific staging tool with regard to the nodal status. Adequate specificity may be obtained by external or endoluminal ultrasound-guided fine needle biopsies. However, uncertainty arises from eventually unrepresentative tissue sampling. The sentinel lymphonodectomy technique may remedy the dilemma, enabling a risk-adapted, individual indication for regional lymphatic dissection. This concept, first introduced in 1977 by Cabanas into the treatment of penis carcinoma, is based on the evidence of orderly and predictable lymphatic drainage pathways. Tumor cell progression within the lymphatic system seems to follow a sequential pattern. Primary draining lymph nodes possess the structural and functional capability to retain and to fight tumor cells efficiently. The 'sentinel node' is defined as the first tumor draining filter, and, if uninvolved, should thus adequately predict the nodal status of the disease. Skip metastases beyond an uninvolved sentinel node are supposed to be a very rare event. The reliability of the 'Cabanas approach', however, was limited by its relatively poor localization technique, and therefore failed to gain widespread acceptance. Unfortunately, the significance of the concept was not fully appreciated at the time. It is to Morton's credit that the procedure was reinstituted in malignant melanoma through a dye injection technique at the primary tumor site. This led to a rapid development and refinement of intraoperative lymphatic mapping. One major step in this process was to use radiolabeled colloids in conjunction with gamma-camera imaging or gamma probe

  10. Sentinel-5: the new generation European operational atmospheric chemistry mission in polar orbit

    Science.gov (United States)

    Pérez Albiñana, Abelardo; Erdmann, Matthias; Wright, Norrie; Martin, Didier; Melf, Markus; Bartsch, Peter; Seefelder, Wolfgang

    2017-08-01

    Sentinel-5 is an Earth Observation instrument to be flown on the Metop Second Generation (Metop-SG) satellites with the fundamental objective of monitoring atmospheric composition from polar orbit. The Sentinel-5 instrument consists of five spectrometers to measure the solar spectral radiance backscattered by the earth atmosphere in five bands within the UV (270nm) to SWIR (2385nm) spectral range. Data provided by Sentinel-5 will allow obtaining the distribution of important atmospheric constituents such as ozone, on a global daily basis and at a finer spatial resolution than its precursor instruments on the first generation of Metop satellites. The launch of the first Metop-SG satellite is foreseen for 2021. The Sentinel-5 instrument is being developed by Airbus DS under contract to the European Space Agency. The Sentinel-5 mission is part of the Space Component of the Copernicus programme, a joint initiative by ESA, EUMETSAT and the European Commission. The Preliminary Design Review (PDR) for the Sentinel-5 development was successfully completed in 2015. This paper provides a description of the Sentinel-5 instrument design and data calibration.

  11. A preliminary study on sentinel lymph node biopsy. Feasibility and predictive ability in oral cavity cancer

    International Nuclear Information System (INIS)

    Chikamatsu, Kazuaki; Kamada, Hideo; Ninomiya, Hiroshi; Takahashi, Katsumasa; Sakurai, Tsutomu; Oriuchi, Noboru; Furuya, Nobuhiko

    2004-01-01

    The main factor that affects the prognosis of patients with head and neck cancer (HNC) is regional lymph node metastases. For this reason, the accurate evaluation of neck metastases is required for neck management. This study investigates the sentinel lymph node identification and the accuracy of the histopathology of the sentinel lymph node in patients with HNC. Eleven patients with histologically proven oral squamous cell carcinoma accessible to radiocolloid injection were enrolled in this study. Using both lymphoscintigraphy and a handheld gamma probe, the sentinel lymph node could be identified in all 11 patients. Subsequently, the sentinel lymph nodes and the neck dissection specimen were examined for lymph node involvement due to tumor. The histopathology of sentinel lymph nodes was consistent with the pathological N classification in all 11 patients. Furthermore, the histopathology of sentinel lymph nodes was superior to physical examination, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) scan. The results of this study indicate that sentinel lymph node identification is technically feasible and predicts cervical metastases in patients with oral cavity cancer. This may be a useful diagnostic technique for identifying lymph node disease in staging lymph node dissection. (author)

  12. Roles of preoperative lymphoscintigraphy for sentinel lymph node biopsy in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xiao; Liu Juanjuan; Wang Yongsheng; Wang Lei; Yang Guoren; Zhou Zhengbo; Li Yongqing; Liu Yanbing; Li Taiyu

    2010-01-01

    The objective of this study was to evaluate roles of preoperative lymphoscintigraphy for sentinel lymph node biopsy in breast cancer patients. Five hundred and sixty-five consecutive breast cancer patients were prospectively randomized into groups with or without preoperative lymphoscintigraphy. In a group with lymphoscintigraphy, 238 patients had sentinel lymph nodes spotted in lymphoscintigram. The visualization of sentinel lymph nodes in lymphoscintigram was not associated with patients' age, primary tumor size and location, histopathologic type and time interval from injection of radiocolloid to lymphoscintigraphy. However, patients with axillary metastasis had a lower identification rate of sentinel lymph nodes by lymphoscintigraphy than those without metastasis (P=0.003). The identification rate of axillary sentinel lymph nodes was 99.3% in the group and the rate was similar whether there was sentinel lymph nodes spotted in axillary in lymphoscintigram or not (99.6% vs. 98.1%, P=0.327). The false-negative rate in this group was 4.2%. While in a group without lymphoscintigraphy, the identification rate and the false-negative rate were 99.6% and 4.8%, respectively. There was no significant difference between the two groups in the identification rate of axillary sentinel lymph nodes (P=0.594) and in the false-negative rate (P=1.00). Preoperative lymphoscintigraphy could neither improve the identification rate nor reduce the false-negative rate of breast cancer sentinel lymph node biopsy, and it is not necessary for sentinel lymph node biopsy in breast cancer patients. (author)

  13. Sentinel lymph node biopsy in endometrial cancer-Feasibility, safety and lymphatic complications.

    Science.gov (United States)

    Geppert, Barbara; Lönnerfors, Céline; Bollino, Michele; Persson, Jan

    2018-03-01

    To compare the rate of lymphatic complications in women with endometrial cancer undergoing sentinel lymph node biopsy versus a full pelvic and infrarenal paraaortic lymphadenectomy, and to examine the overall feasibility and safety of the former. A prospective study of 188 patients with endometrial cancer planned for robotic surgery. Indocyanine green was used to identify the sentinel lymph nodes. In low-risk patients the lymphadenectomy was restricted to removal of sentinel lymph nodes whereas in high-risk patients also a full lymphadenectomy was performed. The impact of the extent of the lymphadenectomy on the rate of complications was evaluated. The bilateral detection rate of sentinel lymph nodes was 96% after cervical tracer injection. No intraoperative complication was associated with the sentinel lymph node biopsy per se. Compared with hysterectomy alone, the additional average operative time for removal of sentinel lymph nodes was 33min whereas 91min were saved compared with a full pelvic and paraaortic lymphadenectomy. Sentinel lymph node biopsy alone resulted in a lower incidence of leg lymphedema than infrarenal paraaortic and pelvic lymphadenectomy (1.3% vs 18.1%, p=0.0003). The high feasibility, the absence of intraoperative complications and the low risk of lymphatic complications supports implementing detection of sentinel lymph nodes in low-risk endometrial cancer patients. Given that available preliminary data on sensitivity and false negative rates in high-risk patients are confirmed in further studies, we also believe that the reduction in lymphatic complications and operative time strongly motivates the sentinel lymph node concept in high-risk endometrial cancer. Copyright © 2017. Published by Elsevier Inc.

  14. Joint Sentinel-1 and SMAP data assimilation to improve soil moisture estimates

    Science.gov (United States)

    Lievens, H.; Reichle, R. H.; Liu, Q.; De Lannoy, G.; Dunbar, R. S.; Kim, S.; Das, N. N.; Cosh, M. H.; Walker, J. P.; Wagner, W.

    2017-12-01

    SMAP (Soil Moisture Active and Passive) radiometer observations at 40 km resolution are routinely assimilated into the NASA Catchment Land Surface Model (CLSM) to generate the SMAP Level 4 Soil Moisture product. The use of C-band radar backscatter observations from Sentinel-1 has the potential to add value to the radiance assimilation by increasing the level of spatial detail. The specifications of Sentinel-1 are appealing, particularly its high spatial resolution (5 by 20 m in interferometric wide swath mode) and frequent revisit time (6 day repeat cycle for the Sentinel-1A and Sentinel-1B constellation). However, the shorter wavelength of Sentinel-1 observations implies less sensitivity to soil moisture. This study investigates the value of Sentinel-1 data for hydrologic simulations by assimilating the radar observations into CLSM, either separately from or simultaneously with SMAP radiometer observations. To facilitate the assimilation of the radar observations, CLSM is coupled to the water cloud model, simulating the radar backscatter as observed by Sentinel-1. The innovations, i.e. differences between observations and simulations, are converted into increments to the model soil moisture state through an Ensemble Kalman Filter. The assimilation impact is assessed by comparing 3-hourly, 9 km surface and root-zone soil moisture simulations with in situ measurements from 9 km SMAP core validation sites and sparse networks, from May 2015 to 2017. The Sentinel-1 assimilation consistently improves surface soil moisture, whereas root-zone impacts are mostly neutral. Relatively larger improvements are obtained from SMAP assimilation. The joint assimilation of SMAP and Sentinel-1 observations performs best, demonstrating the complementary value of radar and radiometer observations.

  15. High-quality MOVPE butt-joint integration of InP/AlGaInAs/InGaAsP-based all-active optical components

    DEFF Research Database (Denmark)

    Kulkova, Irina; Kadkhodazadeh, Shima; Kuznetsova, Nadezda

    2014-01-01

    In this paper, we demonstrate the applicability of MOVPE butt-joint regrowth for integration of all-active InP/AlGaAs/InGaAsP optical components and the realization of high-functionality compact photonic devices. Planar high-quality integration of semiconductor optical amplifiers of various epi...

  16. Wintercuring of Prunus dulcis cv ‘Butte,’ P. webbii and their interspecific hybrid in response to Xylella fastidiosa infections

    Science.gov (United States)

    Clonal replicates of Prunus dulcis cv ‘Butte,’ P. webbii and their interspecific hybrid P 63-61 were inoculated with Xylella fastidiosa strain M23 and evaluated for Almond Leaf Scorch Disease and subsequent wintercuring of infections during three growing seasons. Initial inoculations established gr...

  17. Recreational Use and Value of Water at Elephant Butte and Navajo Reservoirs. New Mexico State University Agricultural Experiment Station Bulletin 535.

    Science.gov (United States)

    Coppedge, Robert O.; Gray, James R.

    This document is a descriptive study of the recreational use and the value of water at Elephant Butte and Navajo Reservoirs. Previous research studies, as well as the study areas and recreational characteristics and procedures of investigation used in this study (sampling and data collection, data organization, analysis) are described. Discussions…

  18. Assessment of undiscovered oil and gas resources in the Uteland Butte Member of the Eocene Green River Formation, Uinta Basin, Utah

    Science.gov (United States)

    Johnson, Ronald C.; Birdwell, Justin E.; Mercier, Tracey J.; Brownfield, Michael E.; Charpentier, Ronald R.; Klett, Timothy R.; Leathers, Heidi M.; Schenk, Christopher J.; Tennyson, Marilyn E.

    2015-09-03

    Using a geology-based assessment methodology, the U.S. Geological Survey estimated mean undiscovered resources of 214 million barrels of oil, 329 billion cubic feet of associated/dissolved natural gas, and 14 million barrels of natural gas liquids in the informal Uteland Butte member of the Green River Formation, Uinta Basin, Utah.

  19. Composite Sunrise Butte pluton: Insights into Jurassic–Cretaceous collisional tectonics and magmatism in the Blue Mountains Province, northeastern Oregon

    Science.gov (United States)

    Johnson, Kenneth H.; Schwartz, J.J.; Žák, Jiří; Verner, Krystof; Barnes, Calvin G.; Walton, Clay; Wooden, Joseph L.; Wright, James E.; Kistler, Ronald W.

    2015-01-01

    The composite Sunrise Butte pluton, in the central part of the Blue Mountains Province, northeastern Oregon, preserves a record of subduction-related magmatism, arc-arc collision, crustal thickening, and deep-crustal anatexis. The earliest phase of the pluton (Desolation Creek unit) was generated in a subduction zone environment, as the oceanic lithosphere between the Wallowa and Olds Ferry island arcs was consumed. Zircons from this unit yielded a 206Pb/238U age of 160.2 ± 2.1 Ma. A magmatic lull ensued during arc-arc collision, after which partial melting at the base of the thickened Wallowa arc crust produced siliceous magma that was emplaced into metasedimentary rocks and serpentinite of the overthrust forearc complex. This magma crystallized to form the bulk of the Sunrise Butte composite pluton (the Sunrise Butte unit; 145.8 ± 2.2 Ma). The heat necessary for crustal anatexis was supplied by coeval mantle-derived magma (the Onion Gulch unit; 147.9 ± 1.8 Ma).The lull in magmatic activity between 160 and 148 Ma encompasses the timing of arc-arc collision (159–154 Ma), and it is similar to those lulls observed in adjacent areas of the Blue Mountains Province related to the same shortening event. Previous researchers have proposed a tectonic link between the Blue Mountains Province and the Klamath Mountains and northern Sierra Nevada Provinces farther to the south; however, timing of Late Jurassic deformation in the Blue Mountains Province predates the timing of the so-called Nevadan orogeny in the Klamath Mountains. In both the Blue Mountains Province and Klamath Mountains, the onset of deep-crustal partial melting initiated at ca. 148 Ma, suggesting a possible geodynamic link. One possibility is that the Late Jurassic shortening event recorded in the Blue Mountains Province may be a northerly extension of the Nevadan orogeny. Differences in the timing of these events in the Blue Mountains Province and the Klamath–Sierra Nevada Provinces suggest that

  20. Sentinel Lymph Node Biopsy in Breast Cancer: A Clinical Review and Update.

    Science.gov (United States)

    Zahoor, Sheikh; Haji, Altaf; Battoo, Azhar; Qurieshi, Mariya; Mir, Wahid; Shah, Mudasir

    2017-09-01

    Sentinel lymph node biopsy has become a standard staging tool in the surgical management of breast cancer. The positive impact of sentinel lymph node biopsy on postoperative negative outcomes in breast cancer patients, without compromising the oncological outcomes, is its major advantage. It has evolved over the last few decades and has proven its utility beyond early breast cancer. Its applicability and efficacy in patients with clinically positive axilla who have had a complete clinical response after neoadjuvant chemotherapy is being aggressively evaluated at present. This article discusses how sentinel lymph node biopsy has evolved and is becoming a useful tool in new clinical scenarios of breast cancer management.

  1. Validation of Land Surface Temperature from Sentinel-3

    Science.gov (United States)

    Ghent, D.

    2017-12-01

    One of the main objectives of the Sentinel-3 mission is to measure sea- and land-surface temperature with high-end accuracy and reliability in support of environmental and climate monitoring in an operational context. Calibration and validation are thus key criteria for operationalization within the framework of the Sentinel-3 Mission Performance Centre (S3MPC). Land surface temperature (LST) has a long heritage of satellite observations which have facilitated our understanding of land surface and climate change processes, such as desertification, urbanization, deforestation and land/atmosphere coupling. These observations have been acquired from a variety of satellite instruments on platforms in both low-earth orbit and in geostationary orbit. Retrieval accuracy can be a challenge though; surface emissivities can be highly variable owing to the heterogeneity of the land, and atmospheric effects caused by the presence of aerosols and by water vapour absorption can give a bias to the underlying LST. As such, a rigorous validation is critical in order to assess the quality of the data and the associated uncertainties. Validation of the level-2 SL_2_LST product, which became freely available on an operational basis from 5th July 2017 builds on an established validation protocol for satellite-based LST. This set of guidelines provides a standardized framework for structuring LST validation activities. The protocol introduces a four-pronged approach which can be summarised thus: i) in situ validation where ground-based observations are available; ii) radiance-based validation over sites that are homogeneous in emissivity; iii) intercomparison with retrievals from other satellite sensors; iv) time-series analysis to identify artefacts on an interannual time-scale. This multi-dimensional approach is a necessary requirement for assessing the performance of the LST algorithm for the Sea and Land Surface Temperature Radiometer (SLSTR) which is designed around biome

  2. Sentinel-2 for rapid operational landslide inventory mapping

    Science.gov (United States)

    Stumpf, André; Marc, Odin; Malet, Jean-Philippe; Michea, David

    2017-04-01

    Landslide inventory mapping after major triggering events such as heavy rainfalls or earthquakes is crucial for disaster response, the assessment of hazards, and the quantification of sediment budgets and empirical scaling laws. Numerous studies have already demonstrated the utility of very-high resolution satellite and aerial images for the elaboration of inventories based on semi-automatic methods or visual image interpretation. Nevertheless, such semi-automatic methods are rarely used in an operational context after major triggering events; this is partly due to access limitations on the required input datasets (i.e. VHR satellite images) and to the absence of dedicated services (i.e. processing chain) available for the landslide community. Several on-going initiatives allow to overcome these limitations. First, from a data perspective, the launch of the Sentinel-2 mission offers opportunities for the design of an operational service that can be deployed for landslide inventory mapping at any time and everywhere on the globe. Second, from an implementation perspective, the Geohazards Exploitation Platform (GEP) of the European Space Agency (ESA) allows the integration and diffusion of on-line processing algorithms in a high computing performance environment. Third, from a community perspective, the recently launched Landslide Pilot of the Committee on Earth Observation Satellites (CEOS), has targeted the take-off of such service as a main objective for the landslide community. Within this context, this study targets the development of a largely automatic, supervised image processing chain for landslide inventory mapping from bi-temporal (before and after a given event) Sentinel-2 optical images. The processing chain combines change detection methods, image segmentation, higher-level image features (e.g. texture, shape) and topographic variables. Based on a few representative examples provided by a human operator, a machine learning model is trained and

  3. Sentinel lymph node biopsy: is it possible to reduce false negative rates by excluding patients with nodular melanoma?

    LENUS (Irish Health Repository)

    Corrigan, M A

    2012-02-03

    OBJECTIVE: The aim of this study was to review the outcome of sentinel lymph node biopsy (SLNB) in patients with melanoma and to delineate whether patients with nodular melanoma are more likely to develop nodal recurrence despite negative SLNB. METHODS: Consecutive patients with cutaneous melanoma undergoing SLNB were identified from a departmental database between 1997 and 2005. Factors including demographic data, site, histological subtype, depth and outcome were examined. RESULTS: Of 131 patients, 103 were node negative and eligible for study. The median age was 53 (16-82) years with 46 patients being male (45%) and 57 female (55%). Primary melanoma sites included lower limb (49; 48%), upper limb (29; 28%), head (12; 11%), trunk (7; 7%) and back (6; 6%). The median Breslow thickness was 2mm. Superficial spreading accounted for 43% of melanoma with nodular accounting for 42%. Median follow-up was 40 (3-90) months. Of 20 relapses, seven recurred in the same nodal basin, three were satellite recurrences, one recurred with both satellite and nodal lesions simultaneously, and nine experienced haematogenous spread. Of the eight patients who developed recurrence in the same nodal basin, four were of nodular histological subtype (p=NS). All of the three patients with satellite lesions had nodular melanoma histologically (p=0.02). When nodal and satellite recurrences were combined, eight of 11 were histologically nodular (p=0.01). CONCLUSIONS: This study indicates that lymphatic recurrence occurs more often in SLNB negative patients with nodular melanoma. Further evaluation of the inclusion criteria for sentinel node biopsy is warranted.

  4. 2014-2016 Mt. Etna Ground deformation imaged by SISTEM approach using GPS and SENTINEL-1A/1B TOPSAR data

    Science.gov (United States)

    Bonforte, Alessandro; Guglielmino, Francesco; Puglisi, Giuseppe

    2017-04-01

    In the frame of the EC FP7 MED-SUV project (call FP7 ENV.2012.6.4-2), and thanks to the GEO-GSNL initiative, GPS data and SENTINEL 1A/1B TOPSAR acquired on Mt. Etna between October 2014 and November 2016 were analyzed. The SENTINEL data were used in order to combine and integrate them with GPS, and detail the ground deformation recorded by GPS on Mt. Etna, during the last two-year's volcanic activity. The Sentinel data were processed by GAMMA software, using a spectral diversity method and a procedure able to co-register the SENTINEL pairs with extremely high precision (processing, a new software architecture based on the hypervisor virtualization technology for the x64 versions of Windows has been implemented. The DInSAR results are analysed and successively used as input for the time series analysis using the StaMPS package. On December 28, 2014 eruptive activity resumed at Mt. Etna with a fire fountain activity feeding two lava flows spreading on the eastern and south-western upper flanks of the volcano, producing evident deformation at the summit of the volcano. GPS displacements and Sentinel-1A ascending interferogram were calculated in order to image the ground deformation pattern accompanying the eruption. The ground deformation pattern has been perfectly depicted by the GPS network, mainly affecting the uppermost part of the volcano edifice, with a strong decay of the deformation, according to a very shallow and strong dyke intrusion. The Sentinel 1A SAR data, covering the similar time spanning, confirmed that most of displacements are related to the dike intrusion, and evidenced a local gravity-driven motion of the western wall of the Valle del Bove, probably related to the dike intrusion. To monitor the temporal successive evolution of ground deformation, we performed an A-DInSAR SENTINEL analysis using the Small BAseline Subset (SBAS) approach included with the StaMPS processing package. The April 2015-December 2015, SBAS Time series, shown a volcano

  5. The speciation of iodine in the salt impacted Black Butte soil series along the Virgin river, Nevada, USA

    International Nuclear Information System (INIS)

    Steinberg, Spencer M.; Buck, Brenda; Morton, Janice; Dorman, James

    2008-01-01

    Salt-impacted soils occur in floodplains, wetlands and backswamps in arid climates. These soils become sinks or temporary storage sites for soluble salts and contaminants including agricultural chemicals, industrial pollutants and radionuclides such as 129 I. The vertical distribution of I in the Black Butte soil series along the Virgin river was assessed and the distribution of I between I - , IO 3 - and organically bound I was determined. The speciation of I was compared to the organic C content, specific components of the organic C, and clay content. This study indicates that organic I was the most abundant form of I in these soil samples and that the content of organic I generally correlated to total organic matter and lignin (as measured by chemolysis) of the samples

  6. The speciation of iodine in the salt impacted Black Butte soil series along the Virgin river, Nevada, USA

    Energy Technology Data Exchange (ETDEWEB)

    Steinberg, Spencer M. [Department of Chemistry, University of Nevada Las Vegas, Las Vegas, NV 80154 (United States)], E-mail: spencer.steinberg@unlv.edu; Buck, Brenda; Morton, Janice [Department of Geoscience, University of Nevada Las Vegas, Las Vegas, NV 80154 (United States); Dorman, James [Department of Chemistry, University of Nevada Las Vegas, Las Vegas, NV 80154 (United States)

    2008-12-15

    Salt-impacted soils occur in floodplains, wetlands and backswamps in arid climates. These soils become sinks or temporary storage sites for soluble salts and contaminants including agricultural chemicals, industrial pollutants and radionuclides such as {sup 129}I. The vertical distribution of I in the Black Butte soil series along the Virgin river was assessed and the distribution of I between I{sup -}, IO{sub 3}{sup -} and organically bound I was determined. The speciation of I was compared to the organic C content, specific components of the organic C, and clay content. This study indicates that organic I was the most abundant form of I in these soil samples and that the content of organic I generally correlated to total organic matter and lignin (as measured by chemolysis) of the samples.

  7. Influence of the phase morphology on the weldability of PLA/PBAT-blends by using butt-welding

    Science.gov (United States)

    Goebel, L.; Bonten, C.

    2014-05-01

    The material development in the field of bioplastics is steadily increasing. It is important to examine the processability but the Investigation of further process steps is also very important. In this paper the weldability of bioplastics is discussed. Compounds of Polylactide (PLA) and Polybutyleneadipate-terephthalate (PBAT) are produced by a twin screw extruder with different mixing ratios. Tensile specimens are produced by injection moulding and the tensile tests are carried out. In order to verify the weldability, some tensile specimens are cut in halfes and butt welded. Afterwards a tensile test is performed with the welded samples and the results are compared with the values of the unwelded samples. For understanding the results, the morphology of the welds were examined and correlated. It has been found that blends with a mixing ratio of 50:50 have the lowest welding factor, because of the immiscibility of PLA and PBAT. Weld images show segregated areas that reduce the force transmission.

  8. Numerical Simulation of Heat and Flow Behaviors in Butt-fusion Welding Process of HDPE Pipes with Curved Fusion Surface

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jae Hyun; Ahn, Kyung Hyun [Seoul National University, Seoul (Korea, Republic of); Choi, Sunwoong; Oh, Ju Seok [Hannam University, Daejeon (Korea, Republic of)

    2017-08-15

    Butt-fusion welding process is used to join the polymeric pipes. Recently, some researchers suggest the curved surface to enhance a welding quality. We investigated how curved welding surface affects heat and flow behaviors of polymer melt during the process in 2D axisymmetric domain with finite element method, and discussed the effect to the welding quality. In this study, we considered HDPE pipes. In heat soak stage, curved phase interface between the melt and solid is shown along the shape of welding surface. In jointing stage, squeezing flow is generated between curved welding surface and phase interface. The low shear rate in fusion domain reduces the alignment of polymer to the perpendicular direction of pipes, and then this phenomenon is expected to help to enhance the welding quality.

  9. The coal deposits of the Alkali Butte, the Big Sand Draw, and the Beaver Creek fields, Fremont County, Wyoming

    Science.gov (United States)

    Thompson, Raymond M.; White, Vincent L.

    1952-01-01

    Large coal reserves are present in three areas located between 12 and 20 miles southeast of Riverton, Fremont County, central Wyoming. Coal in two of these areas, the Alkali Butte coal field and the Big Sand Draw coal field, is exposed on the surface and has been developed to some extent by underground mining. The Beaver Creek coal field is known only from drill cuttings and cores from wells drilled for oil and gas in the Beaver Creek oil and gas field.These three coal areas can be reached most readily from Riverton, Wyo. State Route 320 crosses Wind River about 1 mile south of Riverton. A few hundred yards south of the river a graveled road branches off the highway and extends south across the Popo Agie River toward Sand Draw oil and gas field. About 8 miles south of the highway along the Sand Draw road, a dirt road bears east and along this road it is about 12 miles to the Bell coal mine in the Alkali Butte coal field. Three miles southeast of the Alkali Butte turn-off, 3 miles of oiled road extends southwest into the Beaver Creek oil and gas field. About 6 miles southeast of the Beaver Creek turn-off, in the valley of Little Sand Draw Creek, a dirt road extends east 1. mile and then southeast 1 mile to the Downey mine in the Big Sand Draw coal field. Location of these coal fields is shown on figure 1 with their relationship to the Wind River basin and other coal fields, place localities, and wells mentioned in this report. The coal in the Alkali Butte coal field is exposed partly on the Wind River Indian Reservation in Tps. 1 and 2 S., R. 6 E., and partly on public land. Coal in the Beaver Creek and Big Sand Draw coal fields is mainly on public land. The region has a semiarid climate with rainfall averaging less than 10 in. per year. When rain does fall the sandy-bottomed stream channels fill rapidly and are frequently impassable for a few hours. Beaver Creek, Big Sand Draw, Little Sand Draw, and Kirby Draw and their smaller tributaries drain the area and flow

  10. Prediction of residual stresses and distortions due to laser beam welding of butt joints in pressure vessels

    International Nuclear Information System (INIS)

    Moraitis, G.A.; Labeas, G.N.

    2009-01-01

    A two-level three-dimensional Finite Element (FE) model has been developed to predict keyhole formation and thermo-mechanical response during Laser Beam Welding (LBW) of steel and aluminium pressure vessel or pipe butt-joints. A very detailed and localized (level-1) non-linear three-dimensional transient thermal model is initially developed, which simulates the mechanisms of keyhole formation, calculates the temperature distribution in the local weld area and predicts the keyhole size and shape. Subsequently, using a laser beam heat source model based on keyhole assumptions, a global (level-2) thermo-mechanical analysis of the LBW butt-joint is performed, from which the joint residual stresses and distortions are calculated. All the major physical phenomena associated to LBW, such as laser heat input via radiation, heat losses through convection and radiation, as well as latent heat are accounted for in the numerical model. Material properties and particularly enthalpy, which is very important due to significant material phase changes, are introduced as temperature-dependent functions. The main advantages of the developed model are its efficiency, flexibility and applicability to a wide range of LBW problems (e.g. welding for pressure vessel or pipework construction, welding of automotive, marine or aircraft components, etc). The model efficiency arises from the two-scale approach applied. Minimal or no experimental data are required for the keyhole size and shape computation by the level-1 model, while the thermo-mechanical response calculation by the level-2 model requires only process and material data. Therefore, it becomes possible to efficiently apply the developed simulation model to different material types and varying welding parameters (i.e. welding speed, heat source power, joint geometry, etc.) in order to control residual stresses and distortions within the welded structure

  11. Sentinel-1A Product Geolocation Accuracy: Commissioning Phase Results

    Directory of Open Access Journals (Sweden)

    Adrian Schubert

    2015-07-01

    Full Text Available Sentinel-1A (S1A is an Earth observation satellite carrying a state-of-the-art Synthetic Aperture Radar (SAR imaging instrument. It was launched by the European Space Agency (ESA on 3 April 2014. With the end of the in-orbit commissioning phase having been completed at the end of September 2014, S1A data products are already consistently providing highly accurate geolocation. StripMap (SM mode products were acquired regularly and tested for geolocation accuracy and consistency during dedicated corner reflector (CR campaigns. At the completion of this phase, small geometric inconsistencies had been understood and mitigated, with the high quality of the final product geolocation estimates reflecting the mission’s success thus far. This paper describes the measurement campaign, the methods used during geolocation estimation, and presents best estimates of the product Absolute Location Error (ALE available at the beginning of S1A’s operational phase.

  12. Using Multispectral Sentinel-2 Data to Monitor Submerse Macrophytes

    Science.gov (United States)

    Wolf, Patrick; Roessler, Sebastian; Schneider, Thomas; Melzer, Arnulf

    2012-04-01

    Due to climate change and the involved temperatures of Bavarian freshwater lakes, the invasive submerse macrophytes Elodea nuttallii and Najas marina exhibit a massive expansion. To map these processes, a monitoring system based on remote sensing methods is under development. The main part of the monitoring system is a coupled reflection-/growth-model, which derives biometrical parameters for the EU water framework directive (WFD) by inversion of the reflectance spectra. For operational monitoring tasks a high revisiting time is necessary. Hence, the Sentinel-2 sensor might be very promising, as filling the gap between RapidEye and WorldView2 and between hyperspectral an aerial images. This paper outlines principles, methods and first results of the project.

  13. Bird populations as sentinels of endocrine disrupting chemicals

    Directory of Open Access Journals (Sweden)

    Claudio Carere

    2010-03-01

    Full Text Available Exposure to endocrine disrupting chemicals (EDCs is a widespread phenomenon in nature. Although the mechanisms of action of EDCs are actively studied, the consequences of endocrine disruption (ED at the population level and the adaptations evolved to cope with chronic EDC exposure have been overlooked. Birds probably represent the animal taxon most successfully adapted to synanthropic life. Hence, birds share with humans a similar pattern of exposure to xenobiotics. In this article, we review case studies on patterns of behaviour that deviate from the expectation in bird species exposed to EDCs. We provide behavioural and ecological parameters to be used as endpoints of ED; methodological requirements and caveats based on species-specific life-history traits, behavioural repertoires, developmental styles, and possibility of captive breeding; a list of species that could be used as sentinels to assess the quality of man-made environment.

  14. Bird populations as sentinels of endocrine disrupting chemicals.

    Science.gov (United States)

    Carere, Claudio; Costantini, David; Sorace, Alberto; Santucci, Daniela; Alleva, Enrico

    2010-01-01

    Exposure to endocrine disrupting chemicals (EDCs) is a widespread phenomenon in nature. Although the mechanisms of action of EDCs are actively studied, the consequences of endocrine disruption (ED) at the population level and the adaptations evolved to cope with chronic EDC exposure have been overlooked. Birds probably represent the animal taxon most successfully adapted to synanthropic life. Hence, birds share with humans a similar pattern of exposure to xenobiotics. In this article, we review case studies on patterns of behaviour that deviate from the expectation in bird species exposed to EDCs. We provide behavioural and ecological parameters to be used as endpoints of ED; methodological requirements and caveats based on species-specific life-history traits, behavioural repertoires, developmental styles, and possibility of captive breeding; a list of species that could be used as sentinels to assess the quality of man-made environment.

  15. First Robotic SPECT for Minimally Invasive Sentinel Lymph Node Mapping.

    Science.gov (United States)

    Fuerst, Bernhard; Sprung, Julian; Pinto, Francisco; Frisch, Benjamin; Wendler, Thomas; Simon, Hervé; Mengus, Laurent; van den Berg, Nynke S; van der Poel, Henk G; van Leeuwen, Fijs W B; Navab, Nassir

    2016-03-01

    In this paper we present the usage of a drop-in gamma probe for intra-operative Single-Photon Emission Computed Tomography (SPECT) imaging in the scope of minimally invasive robot-assisted interventions. The probe is designed to be inserted and reside inside the abdominal cavity during the intervention. It is grasped during the procedure using a robotic laparoscopic gripper enabling full six degrees of freedom handling by the surgeon. We demonstrate the first deployment of the tracked probe for intra-operative in-patient robotic SPECT enabling augmented-reality image guidance. The hybrid mechanical- and image-based in-patient probe tracking is shown to have an accuracy of 0.2 mm. The overall system performance is evaluated and tested with a phantom for gynecological sentinel lymph node interventions and compared to ground-truth data yielding a mean reconstruction accuracy of 0.67 mm.

  16. Nanoparticles in Sentinel Lymph Node Assessment in Breast Cancer

    Directory of Open Access Journals (Sweden)

    Michael Douek

    2010-11-01

    Full Text Available The modern management of the axilla in breast cancer relies on surgery for accurate staging of disease and identifying those patients at risk who would benefit from adjuvant chemotherapy. The introduction of sentinel lymph node biopsy has revolutionized axillary surgery, but still involves a surgical procedure with associated morbidity in many patients with no axillary involvement. Nanotechnology encompasses a broad spectrum of scientific specialities, of which nanomedicine is one. The potential use of dual-purpose nanoprobes could enable imaging the axilla simultaneous identification and treatment of metastatic disease. Whilst most applications of nanomedicine are still largely in the laboratory phase, some potential applications are currently undergoing clinical evaluation for translation from the bench to the bedside. This is an exciting new area of research where scientific research may become a reality.

  17. The Basic Radar Altimetry Toolbox for Sentinel 3 Users

    Science.gov (United States)

    Lucas, Bruno; Rosmorduc, Vinca; Niemeijer, Sander; Bronner, Emilie; Dinardo, Salvatore; Benveniste, Jérôme

    2013-04-01

    The Basic Radar Altimetry Toolbox (BRAT) is a collection of tools and tutorial documents designed to facilitate the processing of radar altimetry data. This project started in 2006 from the joint efforts of ESA (European Space Agency) and CNES (Centre National d'Etudes Spatiales). The latest version of the software, 3.1, was released on March 2012. The tools enable users to interact with the most common altimetry data formats, being the most used way, the Graphical User Interface (BratGui). This GUI is a front-end for the powerful command line tools that are part of the BRAT suite. BRAT can also be used in conjunction with Matlab/IDL (via reading routines) or in C/C++/Fortran via a programming API, allowing the user to obtain desired data, bypassing the data-formatting hassle. The BratDisplay (graphic visualizer) can be launched from BratGui, or used as a stand-alone tool to visualize netCDF files - it is distributed with another ESA toolbox (GUT) as the visualizer. The most frequent uses of BRAT are teaching remote sensing, altimetry data reading (all missions from ERS-1 to Saral and soon Sentinel-3), quick data visualization/export and simple computation on the data fields. BRAT can be used for importing data and having a quick look at his contents, with several different types of plotting available. One can also use it to translate the data into other formats such as netCDF, ASCII text files, KML (Google Earth) and raster images (JPEG, PNG, etc.). Several kinds of computations can be done within BratGui involving combinations of data fields that the user can save for posterior reuse or using the already embedded formulas that include the standard oceanographic altimetry formulas (MSS, -SSH, MSLA, editing of spurious data, etc.). The documentation collection includes the standard user manual explaining all the ways to interact with the set of software tools but the most important item is the Radar Altimeter Tutorial, that contains a strong introduction to

  18. The Ocean Surface Topography Sentinel-6/Jason-CS Mission

    Science.gov (United States)

    Giulicchi, L.; Cullen, R.; Donlon, C.; Vuilleumier@esa int, P.

    2016-12-01

    The Sentinel-6/Jason-CS mission consists of two identical satellites flying in sequence and designed to provide operational measurements of sea surface height significant wave high and wind speed to support operational oceanography and climate monitoring. The mission will be the latest in a series of ocean surface topography missions that will span nearly three decades. They follow the altimeters on- board TOPEX/Poseidon through to Jason-3 (launched in January 2016). Jason-CS will continue to fulfil objectives of the reference series whilst introducing a major enhancement in capability providing the operational and science oceanographic community with the state of the art in terms of spacecraft, measurement instrumentation design thus securing optimal operational and science data return. As a secondary objective the mission will also include Radio Occultation user services. Each satellite will be launched sequentially into the Jason orbit (up to 66 latitude) respectively in 2020 and 2025. The principle payload instrument is a high precision Ku/C band radar altimeter with retrieval of geophysical parameters (surface elevation, wind speed and SWH) from the altimeter data require supporting measurements: a DORIS receiver for Precise Orbit Determination; The Climate Quality Advanced Microwave Radiometer (AMR-C) for high stability path delay correction. Orbit tracking data are also provided by GPS & LRA. An additional GPS receiver will be dedicated to radio-occultation measurements. The programme is a part of the European Community Copernicus initiative, whose objective is to support Europe's goals regarding sustainable development and global governance of the environment by providing timely and quality data, information, services and knowledge. The Sentinel-6/Jason-CS in particular is a cooperative mission with contributions from NASA, NOAA, EUMETSAT, ESA, CNES and the European Union.

  19. Early Results from TROPOMI on the Copernicus Sentinel 5 Precursor

    Science.gov (United States)

    Veefkind, J. P.; Kleipool, Q.; Ludewig, A.; Stein-Zweers, D.; Aben, I.; De Vries, J.; Loyola, D. G.; Nett, H.; Richter, A.; Van Roozendael, M.; Siddans, R.; Wagner, T.; Dehn, A.; Zehner, C.; Levelt, P.

    2017-12-01

    The Copernicus Sentinel 5 Precursor (S5P) is the first of the European Sentinels satellites dedicated to monitoring of the atmospheric composition. S5P is planned for launch in the 3rd quarter of 2017. The mission objectives of S5P are to monitor air quality, climate and the ozone layer, in the time period between 2017 and 2023. S5P will fly in a Sun-synchronized polar orbit with a 13:30 hr local equator crossing time. The single payload of the S5P mission is TROPOspheric Monitoring Instrument (TROPOMI), which is developed by The Netherlands in cooperation with the European Space Agency (ESA). TROPOMI is a nadir viewing shortwave spectrometer that measures in the UV-visible wavelength range (267-499 nm), the near infrared (661-775 nm) and the shortwave infrared (2300-2389 nm). With a spatial resolution of better than 7x7 km2 at nadir and almost 20 million measurements per day, TROPOMI will be a major step forward compared to its predecessors OMI (Ozone Monitoring Instrument) and SCIAMACHY (Scanning Imaging Absorption Spectrometer for Atmospheric Chartography). The spatial resolution is combined with a wide swath to allow for daily global coverage. The TROPOMI/S5P geophysical (Level 2) operational data products include nitrogen dioxide, carbon monoxide, ozone (total column, tropospheric column & profile), methane, sulfur dioxide, formaldehyde and aerosol and cloud parameters. The S5P will fly in a so-called loose formation with the U.S. Suomi NPP (National Polar-orbiting Partnership) satellite. The primary objective for this formation flying is to use the cloud clearing capabilities of the VIIRS (Visible Infrared Imager Radiometer Suite). The temporal separation between TROPOMI and VIIRS will be less than 5 minutes. Once this formation has been established, it will enable synergistic data products and scientific research potentials.

  20. SEOM's Sentinel-3/OLCI' project CAWA: advanced GRASP aerosol retrieval

    Science.gov (United States)

    Dubovik, Oleg; litvinov, Pavel; Huang, Xin; Aspetsberger, Michael; Fuertes, David; Brockmann, Carsten; Fischer, Jürgen; Bojkov, Bojan

    2016-04-01

    The CAWA "Advanced Clouds, Aerosols and WAter vapour products for Sentinel-3/OLCI" ESA-SEOM project aims on the development of advanced atmospheric retrieval algorithms for the Sentinel-3/OLCI mission, and is prepared using Envisat/MERIS and Aqua/MODIS datasets. This presentation discusses mainly CAWA aerosol product developments and results. CAWA aerosol retrieval uses recently developed GRASP algorithm (Generalized Retrieval of Aerosol and Surface Properties) algorithm described by Dubovik et al. (2014). GRASP derives extended set of atmospheric parameters using multi-pixel concept - a simultaneous fitting of a large group of pixels under additional a priori constraints limiting the time variability of surface properties and spatial variability of aerosol properties. Over land GRASP simultaneously retrieves properties of both aerosol and underlying surface even over bright surfaces. GRAPS doesn't use traditional look-up-tables and performs retrieval as search in continuous space of solution. All radiative transfer calculations are performed as part of the retrieval. The results of comprehensive sensitivity tests, as well as results obtained from real Envisat/MERIS data will be presented. The tests analyze various aspects of aerosol and surface reflectance retrieval accuracy. In addition, the possibilities of retrieval improvement by means of implementing synergetic inversion of a combination of OLCI data with observations by SLSTR are explored. Both the results of numerical tests, as well as the results of processing several years of Envisat/MERIS data illustrate demonstrate reliable retrieval of AOD (Aerosol Optical Depth) and surface BRDF. Observed retrieval issues and advancements will be discussed. For example, for some situations we illustrate possibilities of retrieving aerosol absorption - property that hardly accessible from satellite observations with no multi-angular and polarimetric capabilities.

  1. Use of sentinel-1 data for vessel detection in South African oceans: Early results

    CSIR Research Space (South Africa)

    Kleynhans, Waldo

    2015-08-01

    Full Text Available taking into consideration local incident angles. Early experimental results show promising vessel detection accuracy using the Sentinel-1 data but that polarization and incidence angle are important parameters to take into consideration when working...

  2. Ice Velocity Measurement from SAR: Comparison of Sentinel-1A and RADARSAT-2

    DEFF Research Database (Denmark)

    Kusk, Anders; Dall, Jørgen

    awaits processing. The first Sentinel-1A Greenland-wide observation campaign was carried out in January-March 2015, and ice velocity fields with nearly complete coverage has already been demonstrated [1]. A preliminary IV map using the DTU IPP processor (not all pairs processed) is attached...... with this abstract. The overlapping temporal coverage of the second RADARSAT-2 campaign and the first Sentinel-1 campaign allows a comparison of the two sensors in terms of: Impact of differing imaging modes (stripmap vs TOPS). The better coverage of Sentinel-1 is at the cost of a reduced azimuth resolution, however......, where the backscatter is more homogeneous, offset-tracking relies instead on speckle tracking, reducing the need for high resolution. With more than one revisit, Sentinel-1 can generate 24-day baselines, and this allows a comparison of the two sensor modes without the influence of the temporal baseline...

  3. Detection of Genetic Alterations in Breast Sentinel Lymph Node by Array-CGH

    National Research Council Canada - National Science Library

    Cavalli, Luciane R

    2005-01-01

    The sentinel lymph node (SLN) is the first node in the mammary gland to harbor malignant cells in breast tumors with metastasis, and SLN positivity is an indication for axillary lymph node dissection...

  4. Outcomes by Ethnicity: Sentinel Lymph Node Status in Women With Breast Cancer

    National Research Council Canada - National Science Library

    Hassett, Mary; Hunt, Kelly K; Keyomarsi, Khandan

    2005-01-01

    .... Race/ethnicity and tumor biology may affect outcomes. Since regional lymph node status and tumor markers are strong prognostic indicators, this study examines the role of sentinel lymph node status (SLNS...

  5. Detection of Genetic Alterations in Breast Sentinel Lymph Node by Array-CGH

    National Research Council Canada - National Science Library

    Cavalli, Luciane R

    2006-01-01

    The sentinel lymph node (SLN) is the first node in the mammary gland to harbor malignant cells in breast tumors with metastasis, and SLN positivity is an indication for axillary lymph node dissection...

  6. HURRICANE AND SEVERE STORM SENTINEL (HS3) FLIGHT REPORTS V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Hurricane and Severe Storm Sentinel (HS3) Flight Reports provide information about flights flown by the WB-57 and Global Hawk aircrafts during the Hurricane and...

  7. Sentinel Lymph Node Occult Metastases Have Minimal Survival Effect in Some Breast Cancer Patients

    Science.gov (United States)

    Detailed examination of sentinel lymph node tissue from breast cancer patients revealed previously unidentified metastases in about 16% of the samples, but the difference in 5-year survival between patients with and without these metastases was very small

  8. The surgical importance of an axillary arch in sentinel node biopsy.

    LENUS (Irish Health Repository)

    Ridgway, P F

    2011-03-01

    When Carl Langer described the aberrant axillary arch in 1846 its relevance in sentinel node biopsy (SNB) surgery could not have been contemplated. The authors define an incidence and elucidate relevance of the arch in SNB of the axilla.

  9. Sentinel node biopsy before neoadjuvant chemotherapy spares breast cancer patients axillary lymph node dissection

    NARCIS (Netherlands)

    van Rijk, Maartje C.; Nieweg, Omgo E.; Rutgers, Emiel J. T.; Oldenburg, Hester S. A.; Valdés Olmos, Renato; Hoefnagel, Cornelis A.; Kroon, Bin B. R.

    2006-01-01

    BACKGROUND: Neoadjuvant chemotherapy in breast cancer patients is a valuable method to determine the efficacy of chemotherapy and potentially downsize the primary tumor, which facilitates breast-conserving therapy. In 18 studies published about sentinel node biopsy after neoadjuvant chemotherapy,

  10. A Dearth of Numbers: The Actuary and the Sentinel in Global Public Health

    OpenAIRE

    Lakoff, Andrew

    2013-01-01

    How do experts respond to a threat whose probability cannot be calculated but whose consequences could be catastrophic? Andrew Lakoff explores the political dynamics of sentinel devices in the case of the 2009 swine flu pandemic.

  11. HURRICANE AND SEVERE STORM SENTINEL (HS3) HURRICANE IMAGING RADIOMETER (HIRAD) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Hurricane and Severe Storm Sentinel (HS3) Hurricane Imaging Radiometer (HIRAD) was collected by the Hurricane Imaging Radiometer (HIRAD), which was a multi-band...

  12. Riparian spiders as sentinels of PCB contamination across heterogeneous aquatic ecosystems

    Science.gov (United States)

    Riparian spiders are being used increasingly to track spatial patterns of contaminants in and fluxing from aquatic ecosystems. However, our understanding of the circumstances under which spiders are effective sentinels of aquatic pollution is limited. The present study tests the ...

  13. High Resolution Mapping of Drought Impacts on Small Waterbodies using Sentinel 1 SAR and Landsat Observations

    Science.gov (United States)

    Slinski, K.; Hogue, T. S.; McCray, J. E.

    2017-12-01

    Drought in semi-arid areas can have substantial impact on ephemeral and small water bodies, which provide critical ecological habitat and have important socio-economic value. This is particularly true in the pastoral areas of East Africa, where these ecosystems provide local communities with water for human and animal consumption and pasture for livestock. However, monitoring the impact of drought on ephemeral and small water bodies in East Africa is challenging because of sparse in situ observational systems. Satellite remote sensing observations have been shown to be a viable option for monitoring surface water change in data-poor regions. Landsat data is widely used to detect open water, but the use of Landsat data in small waterbody studies is limited by its 30-meter spatial resolution. New remote sensing-based tools are necessary to better understand the vulnerability of ephemeral and small waterbodies in semi-arid areas to drought and to monitor drought impacts. This study combines Landsat and Sentinel 1 SAR observations to create a series of monthly waterbody maps over the Awash River basin in Ethiopia depicting the change in surface water from October 2014 to March 2017. The study time period corresponds with a major drought event in the area. Waterbody maps were generated using a 10-meter resolution and utilized to monitor drought impacts on ephemeral and small waterbodies in the Awash River basin over the course of the drought event. Initial results show that surface waterbodies in the lower catchments of the Awash basin were more severely impacted by the drought event than the upper catchments. It is anticipated that the new information provided by this tool will inform decisions affecting the water, energy, agriculture and other sectors in East Africa reliant on water resources, enabling water authorities to better manage future drought events.

  14. Lithological Classification Using Sentinel-2A Data in the Shibanjing Ophiolite Complex in Inner Mongolia, China

    Directory of Open Access Journals (Sweden)

    Wenyan Ge

    2018-04-01

    Full Text Available As a source of data continuity between Landsat and SPOT, Sentinel-2 is an Earth observation mission developed by the European Space Agency (ESA, which acquires 13 bands in the visible and near-infrared (VNIR to shortwave infrared (SWIR range. In this study, a Sentinel-2A imager was utilized to assess its ability to perform lithological classification in the Shibanjing ophiolite complex in Inner Mongolia, China. Five conventional machine learning methods, including artificial neural network (ANN, k-nearest neighbor (k-NN, maximum likelihood classification (MLC, random forest classifier (RFC, and support vector machine (SVM, were compared in order to find an optimal classifier for lithological mapping. The experiment revealed that the MLC method offered the highest overall accuracy. After that, Sentinel-2A image was compared with common multispectral data ASTER and Landsat-8 OLI (operational land imager for lithological mapping using the MLC method. The comparison results showed that the Sentinel-2A imagery yielded a classification accuracy of 74.5%, which was 2.5% and 5.08% higher than those of the ASTER and OLI imagery, respectively, indicating that Sentinel-2A imagery is adequate for lithological discrimination, due to its high spectral resolution in the VNIR to SWIR range. Moreover, different data combinations of Sentinel-2A + ASTER + DEM (digital elevation model and OLI + ASTER + DEM data were tested on lithological mapping using the MLC method. The best mapping result was obtained from Sentinel-2A + ASTER + DEM dataset, demonstrating that OLI can be replaced by Sentinel-2A, which, when combined with ASTER, can achieve sufficient bandpasses for lithological classification.

  15. Influence of previous breast surgery in sentinel lymph node biopsy in patients with breast cancer.

    Science.gov (United States)

    López-Prior, V; Díaz-Expósito, R; Casáns Tormo, I

    The aim of this study was to review the feasibility of selective sentinel lymph node biopsy in patients with previous surgery for breast cancer, as well as to examine the factors that may interfere with sentinel node detection. A retrospective review was performed on 91 patients with breast cancer and previous breast surgery, and who underwent sentinel lymph node biopsy. Patients were divided into two groups according to their previous treatment: aesthetic breast surgery in 30 patients (group I) and breast-conserving surgery in 61 (group II). Lymphoscintigraphy was performed after an intra-tumour injection in 21 cases and a peri-areolar injection in 70 cases. An analysis was made of lymphatic drainage patterns and overall sentinel node detection according to clinical, pathological and surgical variables. The overall detection of the sentinel lymph node in the lymphoscintigraphy was 92.3%, with 7.7% of extra-axillary drainages. The identification rate was similar after aesthetic breast surgery (93.3%) and breast-conserving surgery (91.8%). Sentinel lymph nodes were found in the contralateral axilla in two patients (2.2%), and they were included in the histopathology study. The non-identification rate in the lymphoscintigraphy was 7.7%. There was a significantly higher non-detection rate in the highest histological grade tumours (28.6% grade III, 4.5% grade I and 3.6% grade II). Sentinel lymph node biopsy in patients with previous breast surgery is feasible and deserves further studies to assess the influence of different aspects in sentinel node detection in this clinical scenario. A high histological grade was significantly associated with a lower detection. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  16. Development and field evaluation of the sentinel mosquito arbovirus capture kit (SMACK)

    OpenAIRE

    Johnson, Brian J.; Kerlin, Tim; Hall-Mendelin, Sonja; van den Hurk, Andrew F.; Cortis, Giles; Doggett, Stephen L.; Toi, Cheryl; Fall, Ken; McMahon, Jamie L.; Townsend, Michael; Ritchie, Scott A.

    2015-01-01

    Background Although sentinel animals are used successfully throughout the world to monitor arbovirus activity, ethical considerations and cross-reactions in serological assays highlight the importance of developing viable alternatives. Here we outline the development of a passive sentinel mosquito arbovirus capture kit (SMACK) that allows for the detection of arboviruses on honey-baited nucleic acid preservation cards (Flinders Technology Associates; FTA®) and has a similar trap efficacy as s...

  17. A critical assessment on the role of sentinel node mapping in endometrial cancer.

    Science.gov (United States)

    Bogani, Giorgio; Ditto, Antonino; Martinelli, Fabio; Signorelli, Mauro; Perotto, Stefania; Lorusso, Domenica; Raspagliesi, Francesco

    2015-10-01

    Endometrial cancer is the most common gynecologic malignancy in the developed countries. Although the high incidence of this occurrence no consensus, about the role of retroperitoneal staging, still exists. Growing evidence support the safety and efficacy of sentinel lymph node mapping. This technique is emerging as a new standard for endometrial cancer staging procedures. In the present paper, we discuss the role of sentinel lymph node mapping in endometrial cancer, highlighting the most controversies features.

  18. Sentinel node biopsy (SNB) in malignant melanoma as same day procedure vs delayed procedure

    DEFF Research Database (Denmark)

    Rødgaard, Jes Christian; Kramer, Stine; Stolle, Lars B

    2013-01-01

    The aim of this study was to compare a delayed sentinel node biopsy (dSNB) procedure with a same-day procedure (sSNB) in malignant melanoma. In March 2012, Aarhus University Hospital went from the dSNB to the sSNB procedure defined by lymphoscintigraphy (LS) and sentinel node biopsy (SNB) perform......, essential to keep the morbidity and economic costs low, while keeping the quality of the procedure high....

  19. Infected Donor Biomass and Active Feeding Increase Waterborne Transmission of Ichthyophonus sp. to Rainbow Trout Sentinels.

    Science.gov (United States)

    LaPatra, S E; Kocan, R M

    2016-06-01

    The precise nature of Ichthyophonus sp. transmission among wild fishes has eluded description for over a century. Transmission among piscivores is direct, via ingestion of infected prey, but there is also evidence for waterborne transmission between infected and uninfected individuals. Transmission among planktivores is believed to be via a waterborne infectious cell, but definitive proof of this mechanism has not been forthcoming. To explore possible mechanisms of transmission we used Rainbow Trout Oncorhynchus mykiss as a model system and examined the consequence of housing infected donor fish with uninfected (sentinel) fish, without physical contact. We examined two variables linked to transmission: (1) feeding and nonfeeding sentinel fish, and (2) biomass of infected donor fish. Specific-pathogen free sentinel trout were placed in fine-mesh baskets suspended in tanks containing varying numbers of larger Ichthyophonus-infected donor fish and held for 10 weeks, during which time they were examined by in vitro explant culture for the presence of Ichthyophonus. Treatment groups consisted of fed and unfed sentinels housed with infected donors of increasing biomass. After 10 weeks infection prevalence in fed sentinels was significantly higher than in unfed sentinels, and Ichthyophonus was detected earlier in fed fish than in unfed fish. There was no correlation between infection prevalence and donor biomass in fed sentinels, but there was a strong correlation between infection prevalence and increasing donor biomass in unfed sentinels. These data suggest that Ichthyophonus is maintained in wild fish populations by two distinct mechanisms: (1) waterborne infectious cells ingested directly from the water by planktivores, and (2) both infected prey and waterborne infectious cells ingested by piscivores. Received November 13, 2015; accepted February 13, 2016.

  20. Citrullus lanatus 'sentinel' (watermelon) extract reduces atherosclerosis in LDL receptor-deficient mice.

    Science.gov (United States)

    Poduri, Aruna; Rateri, Debra L; Saha, Shubin K; Saha, Sibu; Daugherty, Alan

    2013-05-01

    Watermelon (Citrullus lanatus or C. lanatus) has many potentially bioactive compounds including citrulline, which may influence atherosclerosis. In this study, we determined the effects of C. lanatus, provided as an extract of the cultivar 'sentinel,' on hypercholesterolemia-induced atherosclerosis in mice. Male low-density lipoprotein receptor-deficient mice at 8 weeks old were given either C. lanatus 'sentinel' extract (2% vol/vol; n=10) or a mixture of matching carbohydrates (2% vol/vol; n=8) as the control in drinking water while being fed a saturated fat-enriched diet for 12 weeks ad libitum. Mice consuming C. lanatus 'sentinel' extract had significantly increased plasma citrulline concentrations. Systolic blood pressure was comparable between the two groups. Consumption of C. lanatus 'sentinel' extract led to lower body weight and fat mass without influencing lean mass. There were no differences in food and water intake and in urine output between the two groups. C. lanatus 'sentinel' extract administration decreased plasma cholesterol concentrations that were attributed to reductions of intermediate-/low-density lipoprotein cholesterol. Plasma concentrations of monocyte chemoattractant protein-1 and interferon-gamma were decreased and those of interleukin-10 were increased in mice consuming C. lanatus 'sentinel' extract. Intake of C. lanatus 'sentinel' extract resulted in reductions of atherosclerosis in both aortic arch and thoracic regions. In conclusion, consumption of C. lanatus 'sentinel' extract led to reduced body weight gain, decreased plasma cholesterol concentrations, improved homeostasis of pro- and anti-inflammatory cytokines, and attenuated development of atherosclerosis without affecting systolic blood pressure in hypercholesterolemic mice. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Mulig forbedret behandling af kolorektal cancer med sentinel lymph node-diagnostik

    DEFF Research Database (Denmark)

    Burgdorf, Stefan Kobbelgaard; Eriksen, Jens Ravn; Gögenur, Ismail

    2014-01-01

    Possibly improved treatment of colorectal cancer by sentinel lymph node mapping Prognosis for colorectal cancer is dependent on radical surgical intervention. Chemotherapy in patients with advanced disease has improved the survival. A considerable proportion of the patients going through radical...... surgery will subsequently relapse. Adjuvant chemotherapy is reserved for patients with lymph node metastases, why undetected malignant lymph nodes will result in understaging and exclusion from the possible benefit of adjuvant chemotherapy. With sentinel lymph node mapping it may be possible to detect...

  2. Nonvariceal upper gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Burke, Stephen J.; Weldon, Derik; Sun, Shiliang; Golzarian, Jafar

    2007-01-01

    Nonvariceal upper gastrointestinal bleeding (NUGB) remains a major medical problem even after advances in medical therapy with gastric acid suppression and cyclooxygenase (COX-2) inhibitors. Although the incidence of upper gastrointestinal bleeding presenting to the emergency room has slightly decreased, similar decreases in overall mortality and rebleeding rate have not been experienced over the last few decades. Many causes of upper gastrointestinal bleeding have been identified and will be reviewed. Endoscopic, radiographic and angiographic modalities continue to form the basis of the diagnosis of upper gastrointestinal bleeding with new research in the field of CT angiography to diagnose gastrointestinal bleeding. Endoscopic and angiographic treatment modalities will be highlighted, emphasizing a multi-modality treatment plan for upper gastrointestinal bleeding. (orig.)

  3. Nonvariceal upper gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Burke, Stephen J.; Weldon, Derik; Sun, Shiliang [University of Iowa, Department of Radiology, Iowa, IA (United States); Golzarian, Jafar [University of Iowa, Department of Radiology, Iowa, IA (United States); University of Iowa, Department of Radiology, Carver College of Medicine, Iowa, IA (United States)

    2007-07-15

    Nonvariceal upper gastrointestinal bleeding (NUGB) remains a major medical problem even after advances in medical therapy with gastric acid suppression and cyclooxygenase (COX-2) inhibitors. Although the incidence of upper gastrointestinal bleeding presenting to the emergency room has slightly decreased, similar decreases in overall mortality and rebleeding rate have not been experienced over the last few decades. Many causes of upper gastrointestinal bleeding have been identified and will be reviewed. Endoscopic, radiographic and angiographic modalities continue to form the basis of the diagnosis of upper gastrointestinal bleeding with new research in the field of CT angiography to diagnose gastrointestinal bleeding. Endoscopic and angiographic treatment modalities will be highlighted, emphasizing a multi-modality treatment plan for upper gastrointestinal bleeding. (orig.)

  4. Predictors of non-sentinel lymph node metastasis in breast cancer patients with positive sentinel lymph node (Pilot study)

    International Nuclear Information System (INIS)

    Eldweny, H.; Alkhaldy, Kh.; Alsaleh, N.; Abdulsamad, M.; Abbas, A.; Hamad, A.; Mounib, Sh.; Essam, T.; Kukawski, P.; Bobin, J.; Oteifa, M.; Amangoono, H.; Abulhoda, F.; Usmani, Sh.; Elbasmy, A.

    2012-01-01

    Background: Sentinel Lymph Node Biopsy [SLNB) procedure was found to be an accurate method of staging the axilla in patients with early stage breast cancer. The standard of care for breast cancer patients with positive SLN metastasis includes complete Axillary Lymph Node Dissection (ALND). Haw ever, in 40-70% of patients, the SLN the only involved axillary node. Factors predicting non SLW metastasis should be identified in order to define subgroups of patient with positive SLN in whom the axilla may be staged by SLNB done. Objective: To identify the factors predicting metastatic involvement of the non-SLNs in breast cancer patients having SLN metastases. Patients and Methods: Data were collected and analyzed from 80 patients with early stage invasive breast cancer (T1, T2, N0, M0) who underwent SLNB at the surgical Oncology Department, Kuwait Cancel control Center (KCCC) between November 2004 and February 2009. SLNB was perfomed using a combined technique (radioactive colloid, and blue dye) in the majority of cases in some cases, only one technique was used. Complete ALND was performed in the case of failure of SLN identification and in patients with positive SLN. Multiple variables (patient, tumor and of SLN identification and in patients with positive SLN. Multiple variables (patient, tumor, and SLN characteristics) with tested as possible predictors of non sentinel lymph node metastasis. Results: The mean age of patients at diagnosis was 46.6 years. The median tumor size was 2 cm. The SLN identification rate was 96.2% (77 out of 80 patients). The SLN was positive in 24 patients(31%), and half of these showed evidence of capsular invasion. The median number of SLNs removed was two. The median number positive SLNs was one. The incidence of non-SLN metatasis associated with positive SLN was 50% (12 out of 24 patients). lymphovascular invasion was found to be the only factor associated with non-SLN metastases. In addition, two trends were observed, though they did

  5. Detection of Irrigated Crops from Sentinel-1 and Sentinel-2 Data to Estimate Seasonal Groundwater Use in South India

    Directory of Open Access Journals (Sweden)

    Sylvain Ferrant

    2017-11-01

    Full Text Available Indian agriculture relies on monsoon rainfall and irrigation from surface and groundwater. The interannual variability of monsoon rainfalls is high, which forces South Indian farmers to adapt their irrigated areas to local water availability. In this study, we have developed and tested a methodology for monitoring these spatiotemporal variations using Sentinel-1 and -2 observations over the Kudaliar catchment, Telangana State (~1000 km2. These free radar and optical data have been acquired since 2015 on a weekly basis over continental areas, at a high spatial resolution (10–20 m that is well adapted to the small areas of South Indian field crops. A machine learning algorithm, the Random Forest method, was used over three growing seasons (January to March and July to November 2016 and January to March 2017 to classify small patches of inundated rice paddy, maize, and other irrigated crops, as well as surface water stored in the small reservoirs scattered across the landscape. The crop production comprises only irrigated crops (less than 20% of the areas during the dry season (Rabi, December to March, to which rain-fed cotton is added to reach 60% of the areas during the monsoon season (Kharif, June to November. Sentinel-1 radar backscatter provides useful observations during the cloudy monsoon season. The lowest irrigated area totals were found during Rabi 2016 and Kharif 2016, accounting for 3.5 and 5% with moderate classification confusion. This confusion decreases with increasing areas of irrigated crops during Rabi 2017. During this season, 16% of rice and 6% of irrigated crops were detected after the exceptional rainfalls observed in September. Surface water in small surface reservoirs reached 3% of the total area, which corresponds to a high value. The use of both Sentinel datasets improves the method accuracy and strengthens our confidence in the resulting maps. This methodology shows the potential of automatically monitoring, in near

  6. The sentinel lymph node spread determines quantitatively melanoma seeding to non-sentinel lymph nodes and survival.

    Science.gov (United States)

    Ulmer, Anja; Dietz, Klaus; Werner-Klein, Melanie; Häfner, Hans-Martin; Schulz, Claudia; Renner, Philipp; Weber, Florian; Breuninger, Helmut; Röcken, Martin; Garbe, Claus; Fierlbeck, Gerhard; Klein, Christoph A

    2018-03-01

    Complete lymph node dissection (CLND) after a positive sentinel node (SN) biopsy provides important prognostic information in melanoma patients but has been questioned for therapeutic use recently. We explored whether quantification of the tumour spread to SNs may replace histopathology of non-sentinel nodes (NSNs) for staging purposes. We quantified melanoma spread in SNs and NSNs in 128 patients undergoing CLND for a positive SN. In addition to routine histopathology, one-half of each of all 1496 SNs and NSNs was disaggregated into a single cell suspension and stained immunocytochemically to determine the number of melanoma cells per 10 6 lymph node cells, i.e. the disseminated cancer cell density (DCCD). We uncovered melanoma spread to NSNs in the majority of patients; however, the tumour load and the proportion of positive nodes were significantly lower in NSNs than in SNs. The relation between SN and NSN spread could be described by a mathematical function with DCCD NSN  = DCCD SN c /10 1 - c (c = 0.69; 95% confidence interval [CI]: 0.62-0.76). At a median follow-up of 67 months, multivariable Cox regression analyses revealed that DCCD SN (p = 0.02; HR 1.34, 95% CI: 1.05-1.71) and the total number of pathologically positive nodes (p = 0.02; HR 1.53, 95% CI: 1.07-2.22) were significant risk factors after controlling for age, gender, thickness of melanoma and ulceration status. A prognostic model based on DCCD SN and melanoma thickness predicted outcome as accurately as a model including pathological information of both SNs and NSNs. The assessment of DCCD SN renders CLND for staging purposes unnecessary. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Non sentinel node involvement prediction for sentinel node micrometastases in breast cancer: nomogram validation and comparison with other models.

    Science.gov (United States)

    Houvenaeghel, Gilles; Bannier, Marie; Nos, Claude; Giard, Sylvia; Mignotte, Herve; Jacquemier, Jocelyne; Martino, Marc; Esterni, Benjamin; Belichard, Catherine; Classe, Jean-Marc; Tunon de Lara, Christine; Cohen, Monique; Payan, Raoul; Blanchot, Jerome; Rouanet, Philippe; Penault-Llorca, Frederique; Bonnier, Pascal; Fournet, Sandrine; Agostini, Aubert; Marchal, Frederique; Garbay, Jean-Remi

    2012-04-01

    The risk of non sentinel node (NSN) involvement varies in function of the characteristics of sentinel nodes (SN) and primary tumor. Our aim was to determine and validate a statistical tool (a nomogram) able to predict the risk of NSN involvement in case of SN micro or sub-micrometastasis of breast cancer. We have compared this monogram with other models described in the literature. We have collected data on 905 patients, then 484 other patients, to build and validate the nomogram and compare it with other published scores and nomograms. Multivariate analysis conducted on the data of the first cohort allowed us to define a nomogram based on 5 criteria: the method of SN detection (immunohistochemistry or by standard coloration with HES); the ratio of positive SN out of total removed SN; the pathologic size of the tumor; the histological type; and the presence (or not) of lympho-vascular invasion. The nomogram developed here is the only one dedicated to micrometastasis and developed on the basis of two large cohorts. The results of this statistical tool in the calculation of the risk of NSN involvement is similar to those of the MSKCC (the similarly more effective nomogram according to the literature), with a lower rate of false negatives. this nomogram is dedicated specifically to cases of SN involvement by metastasis lower or equal to 2 mm. It could be used in clinical practice in the way to omit ALND when the risk of NSN involvement is low. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    Science.gov (United States)

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  9. Identification of the sentinel lymph node using hemosiderin in locally advanced breast cancer

    Directory of Open Access Journals (Sweden)

    PAULO HENRIQUE WALTER DE AGUIAR

    Full Text Available ABSTRACT Objective: to verify the agreement rate in the identification of sentinel lymph node using an autologous marker rich in hemosiderin and 99 Technetium (Tc99 in patients with locally advanced breast cancer. Methods: clinical trial phase 1, prospective, non-randomized, of 18 patients with breast cancer and clinically negative axilla stages T2=4cm, T3 and T4. Patients were submitted to sub-areolar injection of hemosiderin 48 hours prior to sentinel biopsy surgery, and the identification rate was compared at intraoperative period to the gold standard marker Tc99. Agreement between methods was determined by Kappa index. Results: identification rate of sentinel lymph node was 88.9%, with a medium of two sentinel lymph nodes per patients. The study identified sentinel lymph nodes stained by hemosiderin in 83.3% patients (n=15, and, compared to Tc99 identification, the agreement rate was 94.4%. Conclusion: autologous marker rich in hemosiderin was effective to identify sentinel lymph nodes in locally advanced breast cancer patients.

  10. Evaluating TIMP-1, Ki67, and HER2 as markers for non-sentinel node metastases in breast cancer patients with micrometastases to the sentinel node

    DEFF Research Database (Denmark)

    Tvedskov, Tove Filtenborg; Bartels, Annette; Jensen, Maj-Britt

    2011-01-01

    The aim was to investigate whether the biochemical prognostic markers TIMP-1, Ki67, and HER2 could predict metastatic spread to non-sentinel nodes (NSN) in breast cancer patients with micrometastases to sentinel node (SN). We included all breast cancer patients with micrometastases to SN operated...... between 2001 and 2007 at the Department of Breast Surgery, Herlev Hospital. The study was designed as a matched case-control study with 25 cases with micrometastases to SN and, in addition, metastatic spread to NSN and 50 matched controls with micrometastases to SN, but without NSN metastases. Patient...

  11. A mathematical prediction model incorporating molecular subtype for risk of non-sentinel lymph node metastasis in sentinel lymph node-positive breast cancer patients: a retrospective analysis and nomogram development.

    Science.gov (United States)

    Wang, Na-Na; Yang, Zheng-Jun; Wang, Xue; Chen, Li-Xuan; Zhao, Hong-Meng; Cao, Wen-Feng; Zhang, Bin

    2018-04-25

    Molecular subtype of breast cancer is associated with sentinel lymph node status. We sought to establish a mathematical prediction model that included breast cancer molecular subtype for risk of positive non-sentinel lymph nodes in breast cancer patients with sentinel lymph node metastasis and further validate the model in a separate validation cohort. We reviewed the clinicopathologic data of breast cancer patients with sentinel lymph node metastasis who underwent axillary lymph node dissection between June 16, 2014 and November 16, 2017 at our hospital. Sentinel lymph node biopsy was performed and patients with pathologically proven sentinel lymph node metastasis underwent axillary lymph node dissection. Independent risks for non-sentinel lymph node metastasis were assessed in a training cohort by multivariate analysis and incorporated into a mathematical prediction model. The model was further validated in a separate validation cohort, and a nomogram was developed and evaluated for diagnostic performance in predicting the risk of non-sentinel lymph node metastasis. Moreover, we assessed the performance of five different models in predicting non-sentinel lymph node metastasis in training cohort. Totally, 495 cases were eligible for the study, including 291 patients in the training cohort and 204 in the validation cohort. Non-sentinel lymph node metastasis was observed in 33.3% (97/291) patients in the training cohort. The AUC of MSKCC, Tenon, MDA, Ljubljana, and Louisville models in training cohort were 0.7613, 0.7142, 0.7076, 0.7483, and 0.671, respectively. Multivariate regression analysis indicated that tumor size (OR = 1.439; 95% CI 1.025-2.021; P = 0.036), sentinel lymph node macro-metastasis versus micro-metastasis (OR = 5.063; 95% CI 1.111-23.074; P = 0.036), the number of positive sentinel lymph nodes (OR = 2.583, 95% CI 1.714-3.892; P model based on the results of multivariate analysis was established to predict the risk of non-sentinel

  12. How can sentinel navigation surgery abbreviate mediastinal lymph node dissection for lung cancer?

    International Nuclear Information System (INIS)

    Nomori, Hiroaki; Ohtsuka, Takashi; Naruke, Tsuguo; Suemasu, Keiichi

    2004-01-01

    Sentinel nodes (SNs) were examined for 101 patients who had peripheral type non-small cell lung cancer less than 5 cm and had undergone systemic mediastinal lymph node dissection. The surgical procedure was lobectomy in 91, pneumonectomy in 3, and segmentectomy with lymph node dissection in 7. In the CT room, the site for RI injection was marked on the skin, and the angle and depth of the needle required to reach the peritumoral region was determined. The RI was then injected in the RI room. The radioactivity in the lymph nodes was counted before dissection (in vivo counting), and after dissection that (ex vivo counting). SNs were defined as any node for which the count was ≥10 times than the background count. SN identification was finally based on ex vivo data. Of the 101 patients, SNs could be identified in 80 patients (80%). Patients whose SNs could not be identified had a significantly lower forced expiratory volume in one second/forced vital capacity (FEV 1 /FVC) than those with identifiable SNs (p=0.025). Twenty six patients (33%) had SN in the mediastinum, the distribution of which depended on the lobe, ie the No.4 lymph node station in the right upper lobe, the No.4 in the right middle lobe, the No.4 and 7 in the right lower lobe, the No.5 in the left upper lobe, and the No.7 in the left lower lobe. One false negative SN was detected in 25 patients with N 1 or N 2 disease (4%). In vivo and ex vivo counting showed 73% concurrence for the identification of SNs in mediastinal lymph node stations, of which rate was significantly higher than 40% in hilar lymph node stations (p 1 /FVC, such as those with chronic obstructive pulmonary disease. The in vivo identification of mediastinal SNs was reliable as much as the ex vivo. Therefore, the in vivo identification of SNs in the mediastinum could be useful approach to guide mediastinal lymph node sampling or dissection. (author)

  13. Sentinel lymph node identification in breast cancer using periareolar and subdermal injection of the radiopharmaceutical in four points

    International Nuclear Information System (INIS)

    Coelho-Oliveira, Afranio; Rocha, Augusto Cesar Peixoto; Gutfilen, Bianca; Pessoa, Maria Carolina Pinheiro; Fonseca, Lea Mirian Barbosa da

    2004-01-01

    The aim of this study was to identify the sentinel node by periareolar injection of the radiopharmaceutical in four points, regardless of tumor topography. The sentinel node biopsy reduces morbidity in axillary staging. Fifty-seven sentinel node biopsies were prospectively performed in two groups: group A (25 patients) and group B (32 patients). The peritumoral injection technique was used in group A and the new injection technique in four points was used in group B. The sentinel node biopsies were studied by imprint cytology and hematoxylin and eosin staining followed by axillary lymph node dissection in all patients of group A and only in the positive cases of group B. In group A, 88% (22/25) of the sentinel nodes were identified. There was no false negative case; the sensibility and specificity were of 100%. In group B, 96% (31/32) of sentinel nodes were identified and the status of the axillary lymph nodes showed a predictive positive value of 100%. The number of sentinel nodes varied from 1 to 7, mode of 1 and median of 2.7. The hotspot area was 10 to 100 times the background radiation. The periareolar injection in four points seems to be a good lymphatic mapping method for identification of the sentinel node. We suggest the standardization of this site for injections to identify the sentinel node, although further studies to confirm these findings are necessary. (author)

  14. Distributed Processing of Sentinel-2 Products using the BIGEARTH Platform

    Science.gov (United States)

    Bacu, Victor; Stefanut, Teodor; Nandra, Constantin; Mihon, Danut; Gorgan, Dorian

    2017-04-01

    The constellation of observational satellites orbiting around Earth is constantly increasing, providing more data that need to be processed in order to extract meaningful information and knowledge from it. Sentinel-2 satellites, part of the Copernicus Earth Observation program, aim to be used in agriculture, forestry and many other land management applications. ESA's SNAP toolbox can be used to process data gathered by Sentinel-2 satellites but is limited to the resources provided by a stand-alone computer. In this paper we present a cloud based software platform that makes use of this toolbox together with other remote sensing software applications to process Sentinel-2 products. The BIGEARTH software platform [1] offers an integrated solution for processing Earth Observation data coming from different sources (such as satellites or on-site sensors). The flow of processing is defined as a chain of tasks based on the WorDeL description language [2]. Each task could rely on a different software technology (such as Grass GIS and ESA's SNAP) in order to process the input data. One important feature of the BIGEARTH platform comes from this possibility of interconnection and integration, throughout the same flow of processing, of the various well known software technologies. All this integration is transparent from the user perspective. The proposed platform extends the SNAP capabilities by enabling specialists to easily scale the processing over distributed architectures, according to their specific needs and resources. The software platform [3] can be used in multiple configurations. In the basic one the software platform runs as a standalone application inside a virtual machine. Obviously in this case the computational resources are limited but it will give an overview of the functionalities of the software platform, and also the possibility to define the flow of processing and later on to execute it on a more complex infrastructure. The most complex and robust

  15. Upper respiratory tract (image)

    Science.gov (United States)

    The major passages and structures of the upper respiratory tract include the nose or nostrils, nasal cavity, mouth, throat (pharynx), and voice box (larynx). The respiratory system is lined with a mucous membrane that ...

  16. ACA Federal Upper Limits

    Data.gov (United States)

    U.S. Department of Health & Human Services — Affordable Care Act Federal Upper Limits (FUL) based on the weighted average of the most recently reported monthly average manufacturer price (AMP) for...

  17. TROPOMI on the Copernicus Sentinel 5 Precursor: Launched?

    Science.gov (United States)

    Levelt, P.; Veefkind, J. P.; Kleipool, Q.; Ludewig, A.; Aben, I.; De Vries, J.; Loyola, D. G.; Richter, A.; Van Roozendael, M.; Siddans, R.; Tamminen, J.; Wagner, T.; Nett, H.

    2016-12-01

    The Copernicus Sentinel 5 Precursor (S5P) is the first of the European Sentinels satellites dedicated to monitoring of the atmospheric composition. S5P is planned for launch in the 4thquarter of 2016; hopefully in time for the AGU Fall Meeting! The mission objectives of S5P are to monitor air quality, climate and the ozone layer, in the time period between 2017 and 2023. S5P will fly in a Sun-synchronized polar orbit with a 13:30 hr local equator crossing time. The single payload of the S5P mission is TROPOspheric Monitoring Instrument (TROPOMI), which is developed by The Netherlands in cooperation with the European Space Agency (ESA). TROPOMI is a nadir viewing shortwave spectrometer that measures in the UV-visible wavelength range (270-500 nm), the near infrared (710-770 nm) and the shortwave infrared (2314-2382 nm). TROPOMI will have an unprecedented spatial resolution of 7x7 km2at nadir. The spatial resolution is combined with a wide swath to allow for daily global coverage. The TROPOMI/S5P geophysical (Level 2) operational data products include nitrogen dioxide, carbon monoxide, ozone (total column, tropospheric column & profile), methane, sulfur dioxide, formaldehyde and aerosol and cloud parameters. The main heritage for TROPOMI comes from OMI on EOS Aura and SCIAMACHY on Envisat. Many of the lessons learned in these missions have resulted in design improvements for TROPOMI. One of the most striking features is the high spatial resolution of 7x7 km2at nadir. The high spatial resolution serves two goals: (1) emissions sources can be detected with a higher accuracy and (2) the number of cloud-free ground pixels will increase substantially. The higher spatial resolution is also combined with a significantly higher signal-to-noise ratio per ground pixel, compared to OMI. This will further enhance the capabilities of TROPOMI to detect small emissions sources. The S5P will fly in a so-called loose formation with the U.S. Suomi NPP (National Polar

  18. BioSentinel: Biosensors for Deep-Space Radiation Study

    Science.gov (United States)

    Lokugamage, Melissa P.; Santa Maria, Sergio R.; Marina, Diana B.; Bhattacharya, Sharmila

    2016-01-01

    The BioSentinel mission will be deployed on NASA's Exploration Mission 1 (EM-1) in 2018. We will use the budding yeast, Saccharomyces cerevisiae, as a biosensor to study the effect of deep-space radiation on living cells. The BioSentinel mission will be the first investigation of a biological response to space radiation outside Low Earth Orbit (LEO) in over 40 years. Radiation can cause damage such as double stand breaks (DSBs) on DNA. The yeast cell was chosen for this mission because it is genetically controllable, shares homology with human cells in its DNA repair pathways, and can be stored in a desiccated state for long durations. Three yeast strains will be stored dry in multiple microfluidic cards: a wild type control strain, a mutant defective strain that cannot repair DSBs, and a biosensor strain that can only grow if it gets DSB-and-repair events occurring near a specific gene. Growth and metabolic activity of each strain will be measured by a 3-color LED optical detection system. Parallel experiments will be done on the International Space Station and on Earth so that we can compare the results to that of deep space. One of our main objectives is to characterize the microfluidic card activation sequence before the mission. To increase the sensitivity of yeast cells as biosensors, desiccated yeast in each card will be resuspended in a rehydration buffer. After several weeks, the rehydration buffer will be exchanged with a growth medium in order to measure yeast growth and metabolic activity. We are currently working on a time-course experiment to better understand the effects of the rehydration buffer on the response to ionizing radiation. We will resuspend the dried yeast in our rehydration medium over a period of time; then each week, we will measure the viability and ionizing radiation sensitivity of different yeast strains taken from this rehydration buffer. The data obtained in this study will be useful in finalizing the card activation sequence for

  19. Realization of the electrical Sentinel 4 detector integration

    Science.gov (United States)

    Hermsen, M.; Hohn, R.; Skegg, M.; Woffinden, C.; Reulke, R.

    2017-09-01

    The detectors of the Sentinel 4 multi spectral imager are operated in flight at 215K while the analog electronics is operated at ambient temperature. The detector is cooled by means of a radiator. For thermal reasons no active component has been allowed in the cooled area closest to the detector as the passive radiator is restricted in its size. For thermal decoupling of detector and electronics a long distance between detector and electronics is considered ideal as thermal conductivity decreases with the length of the connection. In contradiction a short connection between detector and electronics is ideal for the electronic signals. Only a short connection ensures the signal integrity of both the weak detector output signal but similarly also the clock signals for driving the detector. From a mechanical and thermal point of view the connection requires a certain minimum length. The selected solution serves all these needs but had to approach the limits of what is electrically, mechanically and thermally feasible. In addition, shielding from internal (self distortion) and external distorting signals has to be realized for the connection between FEE(Front End Electronics) and detectors. At the time of the design of the flex it was not defined whether the mechanical structure between FEE and FPA (Focal Plane Assembly) would act as a shielding structure. The physical separation between CCD detector and the Front-end Electronics, the adverse EMI environment in which the instrument will be operated in (the location of the instrument on the satellite is in vicinity to a down-link K-band communication antenna of the S/C) require at least the video output signals to be shielded. Both detectors (a NIR and a UVVIS detector) are sensitive to contamination and difficult to be cleaned in case of any contamination. This brings up extreme cleanliness requirements for the detector in manufacturing and assembly. Effectively the detector has to be kept in an ISO 5 environment and

  20. Identification of transplanting stage of rice using Sentinel-1 data

    Science.gov (United States)

    Hongo, C.; Tosa, T.; Tamura, E.; Sigit, G.; Barus, B.

    2017-12-01

    As the adaptation of climate change, the Government of Indonesia has launched agricultural insurance program for damage of rice by drought, flood and pest and disease. For assessment of the damage ratio and calculation of indemnity, extraction of paddy field and identification of transplanting stage are key issues. In this research, we conducted identification of rice transplanting stage in dry season of 2015, using data from Sentinel-1, for paddy in Cianjur, West Java, Indonesia. As the first step, time series order of backscattering coefficient was analyzed about paddy, forest, villages and fish farming ponds with use of Sentinel-1 data acquired on April 1, April 13, April 25, May 7, May 19, June 24, July 18 and August 11. The result shows that the backscattering coefficient of paddy substantially decreased from data on May 7 and reached minimum value and then after increased toward June. A paddy area showing this change was almost the same area where rice was at harvesting stage and we did field investigation work from August 11 to 13. Considering a growth period of rice in our research site was about 110 days, so the result supported the fact that transplantation of rice was done around May 7. On the other hand, backscattering coefficient of forest, villages and fish farming ponds was constant and showed clear difference from the coefficient of paddy. As the next step, minimum and maximum value of backscattering coefficient were extracted from the data of May 7, May 19 and June 24, respectively. Then increase amount was calculated by deducting the minimum value from the maximum. Finally, using the minimum value of backscattering coefficient and the increased amount, a classification of image was made to identify transplanting stage through maximum likelihood method, decision tree method and threshold setting method (regression analysis by 3σ-rule). As the result, the maximum likelihood method made the most accurate distinguishment about transplanting stage

  1. Sentinel lymph node (Sln) detection in vulvar cancer

    International Nuclear Information System (INIS)

    Grimm, J.; Mende, T.; Lantzsch, T.; Seliger, G.; Koelbl, H.; Buchmann, J.

    2002-01-01

    Full text: The purpose of the study is to verify the feasibility of the sentinel lymph node (SLN) procedure in patients with evidence of vulva cancer. We studied 13 women with early stage (T1/T2) carcinoma of the vulva. One day before surgery a lymphoscintigraphy was done. We injected intradermally an average 76 MBq of 99m Tc-labelled human colloides (Albu-Res(r) in 0.4-0.6 ml NaCI at 4 locations round the tumor regarding the midline. Because of the large particles the colloid was filtered before to obtain the small particle fraction between 200-450 nm. Immediately alter injection a dynamic scintigraphy was performed with 28 images, 1 minute per frame. Additional we made static images, 5 minutes per image, 30 and 120 minutes after injection. The location of the SLN was marked on the skin. The SLN was intraoperatively identified using a hand-held gamma probe. In every case a complete inguino-femoral lymph node dissection was done. In all cases we could show one or more (on average 3) SLN by means of lymphoscintigraphy and in 11/13 cases we could detect SLN by using the gamma probe. Lymph channels were seen in 7/13 dynamic studies. 4/13 patients had lymph node metastasis in the SLN (3/4 cases only the SLN and in 1/4 cases the SLN and one additional lymph node were positive). We did not found any tumor-positive non-sentinel lymph node in case of tumor-negative SLN. The morbidity after operation of patients with vulva cancer is considerable and related to the groin dissection. The selective SLN-biopsy instead of radical groin dissection is feasible to reduce the morbidity without a loss of staging and prognostic factors. This method should be restricted to patients with early stage vulva cancer with clinically uninvolved lymph nodes. Further studies are needed to evaluate the accuracy and clinical validity of this procedure. (author)

  2. Technical Letter Report - Preliminary Assessment of NDE Methods on Inspection of HDPE Butt Fusion Piping Joints for Lack of Fusion

    International Nuclear Information System (INIS)

    Crawford, Susan L.; Cumblidge, Stephen E.; Doctor, Steven R.; Hall, Thomas E.; Anderson, Michael T.

    2008-01-01

    The U.S. Nuclear Regulatory Commission (NRC) has a multi-year program at the Pacific Northwest National Laboratory (PNNL) to provide engineering studies and assessments of issues related to the use of nondestructive evaluation (NDE) methods for the reliable inspection of nuclear power plant components. As part of this program, there is a subtask 2D that was set up to address an assessment of issues related to the NDE of high density polyethylene (HDPE) butt fusion joints. This work is being driven by the nuclear industry wanting to employ HDPE materials in nuclear power plant systems. This being a new material for use in nuclear applications, there are a number of issues related to its use and potential problems that may evolve. The industry is pursuing ASME Code Case N-755 entitled 'Use of Polyethylene (PE) Plastic Pipe for Section III, Division 1, Construction and Section XI Repair/Replacement Activities' that contains the requirements for nuclear power plant applications of HDPE. This Code Case requires that inspections be performed after the fusion joint is made by visually examining the bead that is formed and conducting a pressure test of the joint. These tests are only effective in general if gross through-wall flaws exist in the fusion joint. The NRC wants to know whether a volumetric inspection can be conducted on the fusion joint that will reliably detect lack-of-fusion conditions that may be produced during joint fusing. The NRC has requested that the work that PNNL is conducting be provided to assist them in resolving this inspection issue of whether effective volumetric NDE can be conducted to detect lack of fusion (LOF) in the butt HDPE joints. PNNL had 24 HDPE pipe specimens manufactured of 3408 material to contain LOF conditions that could be used to assess the effectiveness of NDE in detecting the LOF. Basic ultrasonic material properties were measured and used to guide the use of phased arrays and time-of-flight diffraction (TOFD) work that was

  3. Upper gastrointestinal bleeding.

    Science.gov (United States)

    Feinman, Marcie; Haut, Elliott R

    2014-02-01

    Upper gastrointestinal (GI) bleeding remains a commonly encountered diagnosis for acute care surgeons. Initial stabilization and resuscitation of patients is imperative. Stable patients can have initiation of medical therapy and localization of the bleeding, whereas persistently unstable patients require emergent endoscopic or operative intervention. Minimally invasive techniques have surpassed surgery as the treatment of choice for most upper GI bleeding. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Predictors of sentinel lymph node metastases in breast cancer-radioactivity and Ki-67.

    Science.gov (United States)

    Thangarajah, Fabinshy; Malter, Wolfram; Hamacher, Stefanie; Schmidt, Matthias; Krämer, Stefan; Mallmann, Peter; Kirn, Verena

    2016-12-01

    Since the introduction of the sentinel node technique for breast cancer in the 1990s patient's morbidity was reduced. Tracer uptake is known to be dependent from lymph node integrity and activity of macrophages. The aim of this study was to assess whether radioactivity of the tracer can predict sentinel lymph node metastases. Furthermore, a potential association with Ki-67 index was examined. Non-invasive prediction of lymph node metastases could lead to a further decrease of morbidity. We retrospectively analyzed patients with primary breast cancer who underwent surgery at the Department of Obstetrics and Gynecology in the University Hospital of Cologne between 2012 and 2013. Injection of radioactive tracer was done a day before surgery in the department of Nuclear Medicine. Clinical data and radioactivity of the sentinel node measured the day before and intraoperatively were abstracted from patient's files. Of 246 patients, 64 patients had at least one, five patients had two and one patient had three positive sentinel lymph nodes. Occurrence of sentinel lymph node metastases was not associated with preoperative tracer activity (p = 0,319), intraoperative tracer activity of first sentinel node (p = 0,086) or with loss of tracer activity until operation (p = 0,909). There was no correlation between preoperative Ki-67 index and occurrence of lymph node metastases (p = 0,403). In our cohort, there was no correlation between radioactivity and sentinel node metastases. Tracer uptake might not only be influenced by lymph node metastases and does not predict metastatic lymph node involvement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Radiation Protection Considerations about gamma probe-guided intraoperative sentinel lymph node surgery

    International Nuclear Information System (INIS)

    Rodriguez, C.; Jimenez-Hoyuela Garcia, J. L.; Rebollo Aguirre, J. M.; Custodio, A.

    2002-01-01

    The sentinel node concept is based on the sequential dissemination hypothesis. According to it, there's a lymph node (named sentinel node) which is the first receiving cancer cells metastasizing from a primary tumor. Further, others nodes sequentially located might be affected. Surgical performance for several types of cancer includes the complete removal of the tumor and a complete local lymph node dissection (LND). so removing and analyzing the sentinel node may avoid the complete LND. To locate the sentinel node, it's usual the local administration (intradermal injection) of a radiopharmaceutical Tc-99, sulfur colloid (activity about 1 mCi( several hours prior to surgery, and using an intraoperative gamma probe very sensitive to the gamma radiation. Although the activity is injected by the Nuclear Medicine staff, and be exposed to the gamma radiation. In this study we estimated maximum possible doses that would be received by personnel (surgical staff during surgery and pathologists during lumpectomy of the sentinel node). For the surgical staff, to avoid dose errors due to the very low residual activities and not to interfere with the personnel in the surgery room, we estimated doses by taking into account only the physical decay of Tc99m injected. for the pathologists, we estimated the residual activity in the sentinel node with the gamma probe. The highest effective dose rate found was to the surgeon (o,44 μSv/h, respectively. so a surgeon could perform 407 hours/yr, and a pathologist 1717 hours/yr, dedicated exclusively to sentinel node biopsy, before being classified as professionally exposed to radiation, and 4070 and 17170 hours per year, respectively, to surpass the annual limits (national regulations of the European Communities). In short, radiation doses to clinical staff involved in the technique are low, and in normal conditions, by establishing appropriate procedures (precautions during surgery, during manipulation surgical specimen...) control

  6. Thermo-mechanical FE-analysis of butt-welding of a Cu-Fe canister for spent nuclear fuel

    International Nuclear Information System (INIS)

    Josefson, B.L.; Karlsson, L.; Lindgren, L.E.; Jonsson, M.

    1992-10-01

    In the Swedish nuclear waste program it has been proposed that spent nuclear fuel shall be placed in composite copper-steel canisters. These canisters will be placed in holes in tunnels located some 500 m underground in a rock storage. The canisters consists of two cylinders of 4850 mm length, one inner cylinder made of steel and one outer cylinder made of copper. The outer diameter of the canister is 880 mm and the wall thickness for each cylinder is 50 mm. At the storage, the steel cylinder, which contains the spent nuclear fuel, is placed inside the copper cylinder. Thereafter, a copper end is butt welded to the copper cylinder using electron beam welding. To obtain penetration through the thickness with this weld method a backing ring is placed at the inside of the copper cylinder. In the present paper, the temperature, strain and stress fields present during welding and after cooling after welding are calculated numerically using the FE-code NIKE-2D. The aim is to use the results of the present calculations to estimate the risk for creep fracture during the subsequent design life. A large strain formulation is employed for the calculation of transient and residual stresses in the canister based on the calculated history of the temperature field present in the canister during the welding process. The contact algorithm available in NIKE-2D is used to detect possible contact between the steel and copper cylinders during the welding. To simplify the numerical calculations and reduce the computational time, rotational symmetry is assumed. For large gap distances between the steel and copper cylinders the residual stress field is calculated to have a shape similar to that observed in butt welded pipes with maximum axial stress values at the yield stress level. For small gap distances the backing ring will come in contact with the steel cylinder which leads to large residual stresses in the backing ring. The maximum accumulated plastic strain in the weld metal and

  7. Feasibility evaluations for the integration of laser butt welding of tubes in industrial pipe coil production lines

    Science.gov (United States)

    Penasa, Mauro; Colombo, Enrico; Giolfo, Mauro

    1994-09-01

    Due to the good performance shown by laser welded joints, to the quality and repeatability achievable by this welding technique and to its high process productivity, a feature inherent to the laser technology which, together with its high flexibility, allows different operations to be performed by a single source, consistent savings in a production line may be obtained. Therefore laser welding techniques may be of high relevance for industrial applications, provided that a sufficient attention is paid to avoiding a low utilization time to the operating laser source. The paper describes a feasibility study for the integration of a laser source as an automatic unit for circumferential butt welding of tubes in production lines of pipe coils, just before the cold bending station. Using a 6 kW CO2 source, thickness ranging from 3.5 to 11.2 mm in carbon, low alloyed Cr-Mo and austenitic stainless steels, have been successfully welded. Cr-Mo steels require on line preheating treatment, which however can be achieved by laser defocused passes just before welding. The results of the preliminary qualification performed on laser welded joints of the involved topologies of product (materials, diameters and thicknesses) are described together with technological tests required for approval: laser circumferential butt welding of tubes has proven to be effective, with satisfactory and repeatable results and good joint performances. An exhaustive comparison with current welding techniques (TIG, MIG) is then carried out, along with a detailed analysis of the potential advantages and benefits which may be expected by using the laser welding technique, as well as with a first estimation of the investments and running costs. Since laser productivity is saturated only at a rough 35% during the year, an accurate analysis of other possible applications and of a possible lay out of a laser working cell integrated in the factory production lines is performed. Usually little attention is

  8. Upper GI Bleeding in Children

    Science.gov (United States)

    Upper GI Bleeding in Children What is upper GI Bleeding? Irritation and ulcers of the lining of the esophagus, stomach or duodenum can result in upper GI bleeding. When this occurs the child may vomit blood ...

  9. Assessment of NDE Methods on Inspection of HDPE Butt Fusion Piping Joints for Lack of Fusion with Validation from Mechanical Testing

    International Nuclear Information System (INIS)

    Anderson, Michael T.; Cinson, Anthony D.; Crawford, Susan L.; Doctor, Steven R.; Moran, Traci L.; Watts, Michael W.

    2010-01-01

    Studies at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, are being conducted to evaluate nondestructive examinations (NDE) coupled with mechanical testing of butt fusion joints in high-density polyethylene (HDPE) pipe for assessing lack of fusion. The work provides information to the U.S. Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from preliminary assessments using ultrasonic and microwave nondestructive techniques and mechanical testing with the high-speed tensile impact test and the side-bend test for determining joint integrity. A series of butt joints were fabricated in 3408, 12-in. IPS DR-11 HDPE material by varying the fusion parameters to create good joints and joints containing a range of lack-of-fusion conditions. Six of these butt joints were volumetrically examined with time-of-flight diffraction (TOFD), phased-array (PA) ultrasound, and the Evisive microwave system. The outer-diameter weld beads were removed for the microwave inspection. In two of the four pipes, both the outer and inner weld beads were removed and the pipe joints re-evaluated. The pipes were sectioned and the joints destructively evaluated with the side-bend test by cutting portions of the fusion joint into slices that were planed and bent. The last step in this limited study will be to correlate the fusion parameters, nondestructive, and destructive evaluation results to validate the effectiveness of what each NDE technology detects and what each does not detect. The results of the correlation will be used in identifying any future work that is needed.

  10. The study on defects in aluminum 2219-T6 thick butt friction stir welds with the application of multiple non-destructive testing methods

    International Nuclear Information System (INIS)

    Li, Bo; Shen, Yifu; Hu, Weiye

    2011-01-01

    Research highlights: → Friction stir weld-defect forming mechanisms of thick butt-joints. → Relationship between weld-defects and friction stir welding process parameters. → Multiple non-destructive testing methods applied to friction stir welds. → Empirical criterion basing on mass-conservation for inner material-loss defects. → Nonlinear correlation between weld strengths and root-flaw lengths. -- Abstract: The present study focused on the relationship between primary friction stir welding process parameters and varied types of weld-defect discovered in aluminum 2219-T6 friction stir butt-welds of thick plates, meanwhile, the weld-defect forming mechanisms were investigated. Besides a series of optical metallographic examinations for friction stir butt welds, multiple non-destructive testing methods including X-ray detection, ultrasonic C-scan testing, ultrasonic phased array inspection and fluorescent penetrating fluid inspection were successfully used aiming to examine the shapes and existence locations of different weld-defects. In addition, precipitated Al 2 Cu phase coarsening particles were found around a 'kissing-bond' defect within the weld stirred nugget zone by means of scanning electron microscope and energy dispersive X-ray analysis. On the basis of volume conservation law in material plastic deformation, a simple empirical criterion for estimating the existence of inner material-loss defects was proposed. Defect-free butt joints were obtained after process optimization of friction stir welding for aluminum 2219-T6 plates in 17-20 mm thickness. Process experiments proved that besides of tool rotation speed and travel speed, more other appropriate process parameter variables played important roles at the formation of high-quality friction stir welds, such as tool-shoulder target depth, spindle tilt angle, and fixture clamping conditions on the work-pieces. Furthermore, the nonlinear correlation between weld tensile strengths and weld crack

  11. Department of Energy WindSentinel Loan Program Description

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, William J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sturges, Mark H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-12-01

    The U.S. Department of Energy (DOE) currently owns two AXYS WindSentinel buoys that collect a comprehensive set of meteorological and oceanographic data to support resource characterization for wind energy offshore. The two buoys were delivered to DOE’s Pacific Northwest National Laboratory (PNNL) in September, 2014. After acceptance testing and initial performance testing and evaluation at PNNL’s Marine Sciences Laboratory in Sequim, Washington, the buoys have been deployed off the U.S. East Coast. One buoy was deployed approximately 42 km east of Virginia Beach, Virginia from December, 2014 through June, 2016. The second buoy was deployed approximately 5 km off Atlantic City, New Jersey in November, 2015. Data from the buoys are available to the public. Interested parties can create an account and log in to http://offshoreweb.pnnl.gov. In response to a number of inquiries and unsolicited proposals, DOE’s Wind Energy Technologies Office is implementing a program, to be managed by PNNL, to lend the buoys to qualified parties for the purpose of acquiring wind resource characterization data in areas of interest for offshore wind energy development. This document describes the buoys, the scope of the loans, the process of how borrowers will be selected, and the schedule for implementation of this program, including completing current deployments.

  12. Peritumoural vs intratumoural injections in sentinel node lymphoscintigraphy

    International Nuclear Information System (INIS)

    MacFarlane, L.; Cardaci, G.

    2002-01-01

    Full text: Lymphoscintigraphy has emerged as a method of detecting sentinel lymph nodes (SLN) in breast cancer. Our department started performing these studies in 2001, using 99mTc-Colloidal Antimony Sulphide Injection -dose 30-50MBq. Two methods of injection were used: (a) peritumoural plus subdermal injection - 1.25ml volume (PT), or (b) direct intratumoural injection - 0.2ml volume (IT), both followed by 5-10 min of gentle massage. Patients with a non-palpable mass required a hookwire (HW) inserted at time of injection, and a hotpack was applied in lieu of massage. 125 patients were retrospectively assessed, with 45 PT, 37 IT, 38 HW, and 5 patients had cavity injections. For PT injections, 93% had axillary node drainage (AN), 27% had internal mammary node drainage (IM) and 4% had no drainage to nodes, despite delayed imaging. For IT injections, 84% had AN, 24% had IM, 11% showed no drainage. Of patients having HW, 66% had AN, 34% had IM, 26% no drainage. In our experience, PT injection has a higher yield for SLN localisation than direct IT injection. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  13. Biomimetric sentinel reef structures for optical sensing and communications

    Science.gov (United States)

    Fries, David; Hutcheson, Tim; Josef, Noam; Millie, David; Tate, Connor

    2017-05-01

    Traditional artificial reef structures are designed with uniform cellular architectures and topologies and do not mimic natural reef forms. Strings and ropes are a proven, common fisheries and mariculture construction element throughout the world and using them as artificial reef scaffolding can enable a diversity of ocean sensing, communications systems including the goal of sentinel reefs. The architecture and packaging of electronics is key to enabling such structures and systems. The distributed sensor reef concept leads toward a demonstrable science-engineering-informed framework for 3D smart habitat designs critical to stock fish development and coastal monitoring and protection. These `nature-inspired' reef infrastructures, can enable novel instrumented `reef observatories' capable of collecting real-time ecosystem data. Embedding lighting and electronic elements into artificial reef systems are the first systems conceptualized. This approach of bringing spatial light to the underwater world for optical sensing, communication and even a new breed of underwater robotic vehicle is an interdisciplinary research activity which integrates principles of electronic packaging, and ocean technology with art/design.

  14. Sentinel lymphoscintigraphy in malignant melanoma and Merkel cell carcinoma

    International Nuclear Information System (INIS)

    Dekova, M.; Kirov, V.; Donchev, M.; Slavova, M.; Tsarovska, T.

    2013-01-01

    Full text:Introduction: The concept of a biopsy of the sentinel lymph node (SLN) was developed by Mortan in 1992, using blue dye. In 1993. Alex and Krag identified SLN with radiocolloid and gamma probe in case of malignant melanoma. Today, both methods are applied separately or together with a success rate above 90% and false negative rate of 5 %. Materials and Methods: The study includes 10 patients, 9 of whom have been diagnosed with malignant melanoma and 1 – with Merkel cancer. All patients were of a higher risk of lymphatic metastases without distinct clinical symptoms. Lymphoscintigraphy was performed with double-headed SPECT gamma camera Toshiba CGA 7200 UI. The visualized lymph nodes were projected and marked on the skin by a point radioactive source under monitoring. The marked lymph nodes were verified during the operation by staining and patent Blau then removed and studies histopathologically. Results: In all patients the Lymphoscintigraphy visualized SLN, which were surgically found just below the skin markers and removed. In the SLN of one patient a diffuse metastasis was found. In the SLN of nine patients no evidence for metastatic process was found. Conclusion: The technique of marking the SLN with subsequent biopsy is a minimally invasive method for the detection of lymph node metastases in patients with malignant melanoma and Merkel carcinoma with a high degree of reliability of the results

  15. Review of sentinel node procedure in cN0 head and neck squamous cell carcinomas. Guidelines from the French evaluation cooperative subgroup of GETTEC.

    Science.gov (United States)

    Garrel, R; Poissonnet, G; Temam, S; Dolivet, G; Fakhry, N; de Raucourt, D

    2017-04-01

    The reliability of the sentinel lymph node (SN) technique has been established for more than ten years in T1-T2 oral cavity and oropharynx squamous cell carcinoma. Although most authors stress the necessity of rigorous implementation, there are no agreed guidelines. Moreover, other indications have been described, in other anatomical areas of the upper aerodigestive tract and in case of previous surgery or radiotherapy. SN expert teams, under the GETTEC head and neck tumor study group, conducted a review of the key points for implementation in head and neck cancers through guidelines and a review of classical and extended indications. Reliability depends on respecting key points of preoperative landmarking by lymphoscintigraphy, and intraoperative SN sampling and histological analysis. The SN technique is the best means of diagnosing occult lymph node involvement, whatever the primary tumor location, T stage or patient history. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Sentinel Lymph Node Biopsy (SLNB) for Breast Cancer (BC) - Validation Protocol of the Technique

    International Nuclear Information System (INIS)

    Blidaru, A.; Bordea, C.I.; Condrea, Ileana; Albert, Paul

    2006-01-01

    Full text: The sentinel ganglion concept originates in the assumption according to which the primary tumor drains into a specific ganglionar area and then runs through the lymphatic nodes in an orderly, sequential mode. When neoplastic dissemination along the lymphatic pathway occurs, there is an initial invasion of a specific lymph node (rarely more than one) located on the drainage route. That firstly lymph node has been identified as the sentinel node, which mirrors the regional ganglionar status. In order to establish the indication for lymphadenectomy and avoid the situations in which such a surgical procedure would be of no use (N-), the only correct method consists in the identification and biopsy of the sentinel node. Radioactive tracing and/or use of vital staining enable the identification of the regional ganglionar group towards which the primary lesion is draining. The technique of sentinel lymph node identification and biopsy by means of radioactive tracing includes: - pre-surgical lymphoscintigraphy, - identification of the sentinel lymph node and its excisional biopsy, - intra-operative histopathological examination and immunohistochemical stains of the sentinel lymph node. Regional lymphadenectomy serves two major purposes: - diagnosis (axillary lymph node invasion represents an important prognostic factor) and therapeutic (to ensure local control of the disease). Regional lymph node invasion in breast cancer is directly related to the primary tumour size. In the less advanced stages (T1), as there is rarely invasion of the axillary lymph nodes, lymphadenectomy can be avoided in most cases. The paper presents the refinement of the technique, the validation of the method for the identification and biopsy of the sentinel lymph node in breast cancer using Tc99 and the intra-operative use of NEOPROBE 2000 gamma camera at the 'Prof. Dr. Alexandru Trestioreanu' Oncological Institute in Bucharest. 93 patients with primary breast cancer (T1, T2, N0

  17. Developments in the Aerosol Layer Height Retrieval Algorithm for the Copernicus Sentinel-4/UVN Instrument

    Science.gov (United States)

    Nanda, Swadhin; Sanders, Abram; Veefkind, Pepijn

    2016-04-01

    The Sentinel-4 mission is a part of the European Commission's Copernicus programme, the goal of which is to provide geo-information to manage environmental assets, and to observe, understand and mitigate the effects of the changing climate. The Sentinel-4/UVN instrument design is motivated by the need to monitor trace gas concentrations and aerosols in the atmosphere from a geostationary orbit. The on-board instrument is a high resolution UV-VIS-NIR (UVN) spectrometer system that provides hourly radiance measurements over Europe and northern Africa with a spatial sampling of 8 km. The main application area of Sentinel-4/UVN is air quality. One of the data products that is being developed for Sentinel-4/UVN is the Aerosol Layer Height (ALH). The goal is to determine the height of aerosol plumes with a resolution of better than 0.5 - 1 km. The ALH product thus targets aerosol layers in the free troposphere, such as desert dust, volcanic ash and biomass during plumes. KNMI is assigned with the development of the Aerosol Layer Height (ALH) algorithm. Its heritage is the ALH algorithm developed by Sanders and De Haan (ATBD, 2016) for the TROPOMI instrument on board the Sentinel-5 Precursor mission that is to be launched in June or July 2016 (tentative date). The retrieval algorithm designed so far for the aerosol height product is based on the absorption characteristics of the oxygen-A band (759-770 nm). The algorithm has heritage to the ALH algorithm developed for TROPOMI on the Sentinel 5 precursor satellite. New aspects for Sentinel-4/UVN include the higher resolution (0.116 nm compared to 0.4 for TROPOMI) and hourly observation from the geostationary orbit. The algorithm uses optimal estimation to obtain a spectral fit of the reflectance across absorption band, while assuming a single uniform layer with fixed width to represent the aerosol vertical distribution. The state vector includes amongst other elements the height of this layer and its aerosol optical

  18. Survey of Hyperspectral Earth Observation Applications from Space in the Sentinel-2 Context

    Directory of Open Access Journals (Sweden)

    Julie Transon

    2018-01-01

    Full Text Available In the last few decades, researchers have developed a plethora of hyperspectral Earth Observation (EO remote sensing techniques, analysis and applications. While hyperspectral exploratory sensors are demonstrating their potential, Sentinel-2 multispectral satellite remote sensing is now providing free, open, global and systematic high resolution visible and infrared imagery at a short revisit time. Its recent launch suggests potential synergies between multi- and hyper-spectral data. This study, therefore, reviews 20 years of research and applications in satellite hyperspectral remote sensing through the analysis of Earth observation hyperspectral sensors’ publications that cover the Sentinel-2 spectrum range: Hyperion, TianGong-1, PRISMA, HISUI, EnMAP, Shalom, HyspIRI and HypXIM. More specifically, this study (i brings face to face past and future hyperspectral sensors’ applications with Sentinel-2’s and (ii analyzes the applications’ requirements in terms of spatial and temporal resolutions. Eight main application topics were analyzed including vegetation, agriculture, soil, geology, urban, land use, water resources and disaster. Medium spatial resolution, long revisit time and low signal-to-noise ratio in the short-wave infrared of some hyperspectral sensors were highlighted as major limitations for some applications compared to the Sentinel-2 system. However, these constraints mainly concerned past hyperspectral sensors, while they will probably be overcome by forthcoming instruments. Therefore, this study is putting forward the compatibility of hyperspectral sensors and Sentinel-2 systems for resolution enhancement techniques in order to increase the panel of hyperspectral uses.

  19. Evaluating the capabilities of vegetation spectral indices on chlorophyll content estimation at Sentinel-2 spectral resolutions

    Science.gov (United States)

    Sun, Qi; Jiao, Quanjun; Dai, Huayang

    2018-03-01

    Chlorophyll is an important pigment in green plants for photosynthesis and obtaining the energy for growth and development. The rapid, nondestructive and accurate estimation of chlorophyll content is significant for understanding the crops growth, monitoring the disease and insect, and assessing the yield of crops. Sentinel-2 equipped with the Multi-Spectral Instrument (MSI), which will provide images with high spatial, spectral and temporal resolution. It covers the VNIR/SWIR spectral region in 13 bands and incorporates two new spectral bands in the red-edge region and a spatial resolution of 20nm, which can be used to derive vegetation indices using red-edge bands. In this paper, we will focus on assessing the potential of vegetation spectral indices for retrieving chlorophyll content from Sentinel-2 at different angles. Subsequently, we used in-situ spectral data and Sentinel-2 data to test the relationship between VIs and chlorophyll content. The REP, MTCI, CIred-edge, CIgreen, Macc01, TCARI/OSAVI [705,750], NDRE1 and NDRE2 were calculated. NDRE2 index displays a strongly similar result for hyperspectral and simulated Sentinel-2 spectral bands (R2 =0.53, R2 =0.51, for hyperspectral and Sentinel-2, respectively). At different observation angles, NDRE2 has the smallest difference in performance (R2 = 0.51, R2 =0.64, at 0° and 15° , respectively).

  20. Sentinel lymph node mapping in melanoma with technetium-99m dextran.

    Science.gov (United States)

    Neubauer, S; Mena, I; Iglesis, R; Schwartz, R; Acevedo, J C; Leon, A; Gomez, L

    2001-06-01

    The aim of this work is to evaluate the capability of Tc99m B Dextran as a lymphoscintigraphic agent in the detection of the sentinel node in skin lesions. Forty-one patients with melanomas (39) and Merkel cell tumors (2) had perilesional intradermal injection of Tc99m-Dextran 2 hours before surgery. Serial gamma camera images and a handheld gamma probe were used to direct sentinel node biopsy. In 39/41 patients, lymph channels and 52 sentinel nodes (one to three sentinel nodes/patient) could be visualized. In one patient, with a dorsal melanoma, no lymph channels or lymph nodes could be demonstrated on the images and only minimal radioactivity was found in the regional nodes with the probe. Another patient with a facial lesion failed to demonstrate lymph channels or nodes. No adverse reactions were observed. Tc99m-Dextran provided good definition of lymph channels and sentinel node localization, without the risks related to the use of potentially hazardous labeled materials of biological origin.

  1. Effect of Friction Stir Welding Parameters on the Mechanical and Microstructure Properties of the Al-Cu Butt Joint

    Directory of Open Access Journals (Sweden)

    Sare Celik

    2016-05-01

    Full Text Available Friction Stir Welding (FSW is a solid-state welding process used for welding similar and dissimilar materials. FSW is especially suitable to join sheet Al alloys, and this technique allows different material couples to be welded continuously. In this study, 1050 Al alloys and commercially pure Cu were produced at three different tool rotation speeds (630, 1330, 2440 rpm and three different tool traverse speeds (20, 30, 50 mm/min with four different tool position (0, 1, 1.5, 2 mm by friction stir welding. The influence of the welding parameters on the microstructure and mechanical properties of the joints was investigated. Tensile and bending tests and microhardness measurements were used to determine the mechanical properties. The microstructures of the weld zone were investigated by optical microscope and scanning electron microscope (SEM and were analyzed in an energy dispersed spectrometer (EDS. Intermetallic phases were detected based on the X-ray diffraction (XRD analysis results that evaluated the formation of phases in the weld zone. When the welding performance of the friction stir welded butt joints was evaluated, the maximum value obtained was 89.55% with a 1330 rpm tool rotational speed, 20 mm/min traverse speed and a 1 mm tool position configuration. The higher tensile strength is attributed to the dispersion strengthening of the fine Cu particles distributed over the Al material in the stir zone region.

  2. Study of Defect Sizing in Carbon Steel Butt Welds using Conventional Ultrasonic Technique and Phased Array Ultrasonic

    International Nuclear Information System (INIS)

    Amry Amin Abas; Noorhazleena Azaman; Mohd Yusnisyam Mohd Yusoff

    2016-01-01

    Ultrasonic testing is a proven reliable method which is able to detect and measure the size of defects in butt welds with acceptable tolerance. Recent advancement of technology has introduced a computerized technique which is phased array. Phased array employs focal law that enable focusing and steering of beam at the active aperture axis. This enables one line scanning but covering the whole weld volume as compared to conventional technique which employs aster scan and multiple probes to completely cover the whole weld volume. Phased array also gives multiple data view which assist the interpreter. This paper is about the study of these two techniques and technical analysis of comparison between the two. The conventional technique is performed using GE USM GO with 4 MHz 45 degrees shear wave probe. The phased array technique uses OLYMPUS OMNISCAN MX2 with 5L64 linear array probe with 16 elements aperture and 55 degrees wedge emitting shear wave into the specimen. Sensitivity of both techniques are based on 1.5 mm Side Drilled Hole. The results are compared and analysis such as defect sizing and defect type determination are performed. (author)

  3. Utilizing the geochemical data from the National Uranium Resource Evaluation (NURE) program: an evaluation of the Butte quadrangle, Montana

    International Nuclear Information System (INIS)

    Van Eeckhout, E.M.

    1980-12-01

    Some 1370 water and 1951 sediment samples were collected from 1994 locations in the Butte quadrangle, Montana, in 1976 and 1977 by the University of Montana for the Los Alamos Scientific Laboratory (LASL). The LASL analyzed the water samples for uranium and the sediment samples for uranium plus 42 additional elements. The data were then released to the Montana College of Mineral Science and Technology (MCMS and T), which was responsible for the evaluation of the uranium data. The data have subsequently been released by the LASL in an open-file report (Broxton, 1980). Statistical evaluations of the data were undertaken for uranium, copper, lead, zinc, manganese, gold, and silver. The uranium evaluations indicated certain areas in the western part of the quadrangle to be favorable for further investigation (particularly along the Rock Creek), as well as anomalous areas just north of Anaconda. The entire Boulder Batholith area had a high uranium background, but there didn't appear to be any particular site in this area that might be worth pursuing. The multielement evaluations confirmed the known base and precious metal provinces within the quadrangle. A methodology for evaluating data tapes from the National Uranium Resource Evaluation (NURE) program was developed and presented throughout this report. This methodology could be developed further to define areas worth exploring for commodities other than uranium

  4. A Study on the Optimal Welding Condition for Root-Pass in Horizontal Butt-Joint TIG Welding

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Sung Hun; Kim, Jae-Woong [Yeungnam Univ., Gyeongsan (Korea, Republic of)

    2017-04-15

    In this study, to investigate the shape of the back bead as a weld quality parameter and to select the optimal condition of the root-pass TIG welding of a horizontal butt-joint, an experimental design and the response surface method (RSM) have been employed. Three parameters are used as input variables, which include the base current, peak current, and welding speed. The back bead width is selected as an output variable representing the weld quality, the target value of the width is 5.4 mm. Conducting the experiments according to the Box-Behnken experimental design, a 2nd regression model for the back bead width was made, and the validation of the model was confirmed by using the F-test. The desirability function was designed through the nominal-the-best formula for the appropriate back bead width. Finally, the following optimal condition for welding was selected using the RSM: base current of 0.9204, peak current of 0.8676, and welding speed of 0.3776 in coded values. For verification, a test welding process under the optimal condition was executed and the result showed the back bead width of 5.38 mm that matched the target value well.

  5. A Study on the Optimal Welding Condition for Root-Pass in Horizontal Butt-Joint TIG Welding

    International Nuclear Information System (INIS)

    Jung, Sung Hun; Kim, Jae-Woong

    2017-01-01

    In this study, to investigate the shape of the back bead as a weld quality parameter and to select the optimal condition of the root-pass TIG welding of a horizontal butt-joint, an experimental design and the response surface method (RSM) have been employed. Three parameters are used as input variables, which include the base current, peak current, and welding speed. The back bead width is selected as an output variable representing the weld quality, the target value of the width is 5.4 mm. Conducting the experiments according to the Box-Behnken experimental design, a 2nd regression model for the back bead width was made, and the validation of the model was confirmed by using the F-test. The desirability function was designed through the nominal-the-best formula for the appropriate back bead width. Finally, the following optimal condition for welding was selected using the RSM: base current of 0.9204, peak current of 0.8676, and welding speed of 0.3776 in coded values. For verification, a test welding process under the optimal condition was executed and the result showed the back bead width of 5.38 mm that matched the target value well.

  6. Comparison of Corner-Butt 45 (Cb-45 and Corner-Lap (Cl joints in friction stir welding

    Directory of Open Access Journals (Sweden)

    Setiawan Widia

    2018-01-01

    Full Text Available The 10 mm thick Aluminum 6061 plates have been corner joined using varied design and those were 45° Corner Butt and Corner Lap Joints (CB-45 & CL. Friction tool was hardened EMS 45. True experimental method was used with independent parameters is feed rate which varied at 10 mm/min, 15 mm/min and 30 mm/min respectively. Other parameter such as rotating speed was kept constant. Experiment results show that, CB-45 yields better properties than CL. The tensile strength of CB-45 reaches 163.7 MPa for 10 mm/min feed rate. Whilst CL produces joint with tensile strength equal 120 MPa for equal parameters. Microstructure observation showed that CB-45 produces fine and homogenous appearance of MgO compared to CL. This phenomenon is caused by the pin of CB-45 joint which fully penetrates the nugget zone which is not found in CL design. This microstructure in turn promotes higher tensile strength of CB-45.

  7. Noble Gas Isotope Evidence for Mantle Volatiles in the Cu-Mo Porphyry and Main Stage Polymetallic Veins at Butte, Montana

    Science.gov (United States)

    Hofstra, A. H.; Rusk, B. G.; Manning, A. H.; Hunt, A. G.; Landis, G. P.

    2017-12-01

    Recent studies suggest that volatiles released from mafic intrusions may be important sources of heat, sulfur, and metals in porphyry Cu-Mo-Au and epithermal Au-Ag deposits associated with intermediate to silicic stocks. The huge Cu-Mo porphyry and Main Stage polymetallic vein deposits at Butte are well suited to test this hypothesis because there is no geologic or isotopic evidence of basaltic intrusions in the mine or drill holes. The Butte porphyry-vein system is associated with quartz monzonite stocks and dikes within the southwest part of the Late Cretaceous Boulder batholith. The Boulder batholith was emplaced into Mesoproterozoic to Mesozoic sedimentary rocks and Late Cretaceous volcanic rocks. The Boulder batholith and Butte intrusions have Sri and eNd values indicative of crustal contamination. Eu and Ce anomalies in zircon from Butte intrusions provide evidence of oxidation due to magma degassing. To ascertain the source of volatiles in this system, 11 samples from the Cu-Mo porphyry and 16 from Main Stage veins were selected. The isotopic composition of Ar, Ne, and He extracted from fluid inclusions in quartz, magnetite, pyrite, chalcopyrite, sphalerite, galena, enargite, and covellite were determined. Helium isotopes exceed blank levels in all samples and Ne and Ar in some samples. On a 38Ar/36Ar vs. 40Ar/36Ar diagram, data plot near air. On a 20Ne/22Ne vs. 21Ne/22Ne diagram, data extend from air along the trajectories of OIB and MORB. On a 36Ar/4He vs. 3He/4He RA diagram, data extend from crust toward the air-mantle mixing line. The maximum 3He/4He RA values in the Cu-Mo porphyry (2.86) and Main Stage veins (3.46) are from pyrite and these values correspond to 36 and 43 % mantle helium. The Ne and He results show that fluid inclusions contain volatiles discharged from mantle magmas and that these volatiles were diluted by groundwater containing He derived from country rocks. Despite the lack of mafic intrusions in the Butte magmatic center, noble gas

  8. Right upper quadrant pain

    International Nuclear Information System (INIS)

    Ralls, P.W.; Colletti, P.M.; Boswell, W.D. Jr.; Halls, J.M.

    1984-01-01

    Historically, assessment of acute right upper quadrant abdominal pain has been a considerable clinical challenge. While clinical findings and laboratory data frequently narrow the differential diagnosis, symptom overlap generally precludes definitive diagnosis among the various diseases causing acute right upper quadrant pain. Fortunately, the advent of newer diagnostic imaging modalities has greatly improved the rapidity and reliability of diagnosis in these patients. An additional challenge to the physician, with increased awareness of the importance of cost effectiveness in medicine, is to select appropriate diagnostic schema that rapidly establish accurate diagnoses in the most economical fashion possible. The dual goals of this discussion are to assess not only the accuracy of techniques used to evaluate patients with acute right upper quadrant pain, but also to seek out cost-effective, coordinated imaging techniques to achieve this goal

  9. Factors with regard to computerisation of the Dutch and the Belgian national general practitioner sentinel networks: a comparative analysis.

    NARCIS (Netherlands)

    Schweikardt, C.; Casteren, V. van; Verheij, R.A.; Coppieters, Y.

    2013-01-01

    Background: A general practitioner (GP) sentinel network observes a sample of the population by supplying reports on the incidence and epidemiological characteristics of specific diseases and on procedures in primary health care. In the 1970s, the Dutch and the Belgian national GP sentinel networks

  10. Stage migration after introduction of sentinel lymph node dissection in breast cancer treatment in Denmark: a nationwide study

    DEFF Research Database (Denmark)

    Tvedskov, Tove Filtenborg; Jensen, Maj-Britt; Balslev, Eva

    2011-01-01

    To estimate the size and therapeutic consequences of stage migration after introduction of sentinel lymph node dissection (SLND) in breast cancer treatment in Denmark.......To estimate the size and therapeutic consequences of stage migration after introduction of sentinel lymph node dissection (SLND) in breast cancer treatment in Denmark....

  11. EVALUATION OF THE COMPUTED TOMOGRAPHIC "SENTINEL CLOT SIGN" TO IDENTIFY BLEEDING ABDOMINAL ORGANS IN DOGS WITH HEMOABDOMEN.

    Science.gov (United States)

    Specchi, Swan; Auriemma, Edoardo; Morabito, Simona; Ferri, Filippo; Zini, Eric; Piola, Valentina; Pey, Pascaline; Rossi, Federica

    2017-01-01

    The CT "sentinel clot sign" has been defined as the highest attenuation hematoma adjacent to a bleeding organ in humans with hemoabdomen. The aims of this retrospective descriptive multicenter study were to describe CT findings in a sample of dogs with surgically or necropsy confirmed intra-abdominal bleeding and determine prevalence of the "sentinel clot sign" adjacent to the location of bleeding. Medical records between 2012 and 2014 were searched for dogs with hemoabdomen and in which the origin of the bleeding was confirmed either with surgery or necropsy. Retrieved CT images were reviewed for the presence and localization of the "sentinel clot sign," HU measurements of the "sentinel clot sign" and hemoabdomen, and presence of extravasation of contrast media within the abdominal cavity. Nineteen dogs were included. Three dogs were excluded due to the low amount of blood that did not allow the identification of a "sentinel clot sign." A "sentinel clot sign" was detected in the proximity of the confirmed bleeding organ in 14/16 (88%) of the patients. The mean HU of the "sentinel clot sign" was 56 (range: 43-70) while that of the hemoabdomen was 34 (range: 20-45). Active hemorrhage was identified as extravasation of contrast medium within the peritoneal cavity from the bleeding organ in three dogs. In conclusion, the CT "sentinel clot sign" may be helpful for identifying the source of bleeding in dogs with hemoabdomen. © 2016 American College of Veterinary Radiology.

  12. Comparison of 2008-2009 water years and historical water-quality data, upper Gunnison River Basin, Colorado

    Science.gov (United States)

    Solberg, Patricia A.; Moore, Bryan; Blacklock, Ty D.

    2012-01-01

    Population growth and changes in land use have the potential to affect water quality and quantity in the upper Gunnison River Basin. In 1995, the U.S. Geological Survey (USGS), in cooperation with the Bureau of Land Management, City of Gunnison, Colorado River Water Conservation District, Crested Butte South Metropolitan District, Gunnison County, Hinsdale County, Mount Crested Butte Water and Sanitation District, National Park Service, Town of Crested Butte, U.S. Forest Service, Upper Gunnison River Water Conservancy District, and Western State College, established a water-quality monitoring program in the upper Gunnison River Basin to characterize current water-quality conditions and to assess the effects of increased urban development and other land-use changes on water quality. The monitoring network has evolved into two groups of sites: (1) sites that are considered long term and (2) sites that are considered rotational. Data from the long-term sites assist in defining temporal changes in water quality (how conditions may change over time). The rotational sites assist in the spatial definition of water-quality conditions (how conditions differ throughout the basin) and address local and short-term concerns. Biannual summaries of the water-quality data from the monitoring network provide a point of reference for stakeholder discussions regarding the location and purpose of water-quality monitoring sites in the upper Gunnison River Basin. This report compares and summarizes the data collected during water years 2008 and 2009 to the historical data available at these sites. The introduction provides a map of the sampling sites, definitions of terms, and a one-page summary of selected water-quality conditions at the network sites. The remainder of the report is organized around the data collected at individual sites. Data collected during water years 2008 and 2009 are compared to historical data, State water-quality standards, and Federal water-quality guidelines

  13. Approaching target: A service for nationwide deformation monitoring in Denmark using Sentinel-1

    DEFF Research Database (Denmark)

    Fredenslund Levinsen, Joanna; Sørensen, Carlo Sass; Broge, Niels Henrik

    processes in both the public and private sectors. This will inevitably lead to significant economic savings. The test study makes up part of the foundation for establishing a nationwide service. As such, the results over the test sites will be presented to a broad range of end-users to identify their needs...... tailored to specific needs, which increases the probability of its implementation in both the public and private sectors. Presenting the results obtained on the road to setting up a nationwide deformation monitoring will clearly demonstrate the potentials arising with the continuous stream of Sentinel-1......Building upon decades of experience with deformation monitoring from repeated precision leveling and GNSS measurements as well as more recent time series analyses of ERS, Envisat, and Sentinel-1 imagery, we are now working towards a nationwide mapping using Sentinel-1 Interferometric Wide Swath...

  14. SenThIS - Sentinels of Thuringian information systems

    Science.gov (United States)

    Naue, Sandra; Krause, Peter

    2016-04-01

    Decision-making for sustainable environmental resource management or risk prevention is facing the problem of constantly changing conditions related to the projected changes of climate, demography and socio-economy. Herefore, adaptable tools and methods which can reflect such changes are needed for an efficient management. The need to improve existing tools is a challenge the departments of German environmental authorities at state and federal level are facing at this time. Additionally the increasing demands for work process optimization due to financial cutbacks are coming into play. Consequently the need for suitable adaptation measurements for short and long term changes of environmental state variables is growing. The importance of spatio-temporal data, providing continuous observation about the state of the environmental system and its changes, is therefore increasing in order to elaborate adaptation strategies. In this case earth observation is a useful source for the required data. With the new Sentinel fleet, ESA's Copernicus Program is providing a possibility to obtain such information free in high temporal and spatial resolution. The BMVI funded project SenThIS, a collaborative project by the Thuringian State Institute for Environment and Geology (TLUG), the Thuringian Forest Department and two SMEs EOS GmbH and Feiffer consult is aiming at utilizing Copernicus data and services for operational tasks on a federal level. It addresses this aforementioned deficit through the development and implementation of a processing chain for synergetic and automated application of remote sensing data and products to accomplish operational state tasks. The product development is characterized by the synergetic application of remote sensing data and suitable models. Design and calibration of the models base on Sentinel 1/2 data and additional information (e.g. meteorological data, in-situ measurements). This results in products of highly temporal and spatial resolution

  15. Sentinel and other mutational effects in offspring of cancer survivors

    International Nuclear Information System (INIS)

    Mulvihill, J.J.

    1990-01-01

    To date, no agent has been documented to cause germ cell mutation in human beings, with the possible exception of radiation causing abnormal meiotic chromosomes in testes. For studies in humans, mutation epidemiologists prefer the cohort approach, starting with an exposed population and looking for mutations that may be expressed in offspring as variants in health, chromosomes, proteins, or nucleic acids. Currently patients with cancer are the cohort exposed to the largest doses of potential mutagens, i.e., radiotherapy and drugs. In 12 large studies with over 825 patients and 1573 pregnancies, 46 (4%) of 1240 liveborns had a major birth defect, a rate comparable to that in the general population. One of these was a classic sentinel phenotype, i.e., a new sporadic case of a dominant mendelian syndrome. In collaboration with 5 U.S. cancer registries, we interviewed a retrospective cohort of 2383 patients diagnosed with cancer under age 20 years, from 1945 through 1975. Records were sought to verify major genetic disease, defined as a cytogenetic or single gene disorder or 1 of 15 isolated birth defects. In 2308 offspring of survivors, 5 had a chromosomal syndrome, 11 had a single gene disorder, and 62 had at least one major malformation. Among 4722 offspring of sibling controls, the respective numbers were 7, 12, and 127, nonsignificant differences. 7% of the parents of the offspring with possibly new mutations received potentially mutagenic therapy, compared with 12% of parents of normal children. Since pregnancy in or by cancer survivors is still a rare event, future efforts to document germ cell mutation may be best studied through international cooperation coupled with diverse laboratory measures of mutation

  16. Can Breast Cancer Biopsy Influence Sentinel Lymph Node Status?

    Science.gov (United States)

    Giuliani, Michela; Patrolecco, Federica; Rella, Rossella; Di Giovanni, Silvia Eleonora; Infante, Amato; Rinaldi, Pierluigi; Romani, Maurizio; Mulè, Antonino; Arciuolo, Damiano; Belli, Paolo; Bonomo, Lorenzo

    2016-12-01

    We evaluated whether the needle size could influence metastasis occurrence in the axillary sentinel lymph node (SLN) in ultrasound-guided core needle biopsy (US-CNB) of breast cancer (BC). The data from all patients with breast lesions who had undergone US-CNB at our institution from January 2011 to January 2015 were retrospectively reviewed. A total of 377 BC cases were included using the following criteria: (1) percutaneous biopsy-proven invasive BC; and (2) SLN dissection with histopathologic examination. The patients were divided into 2 groups according to the needle size used: 14 gauge versus 16 or 18 gauge. SLN metastasis classification followed the 7th American Joint Committee on Cancer (2010) TNM pathologic staging factors: macrometastases, micrometastases, isolated tumor cells, or negative. Only macrometastases and micrometastases were considered positive, and the positive and negative rates were calculated for the overall population and for both needle size groups. Of the 377 BC cases, 268 US-CNB procedures were performed using a 14-gauge needle and 109 with a 16- or 18-gauge needle, respectively. The negative rate was significantly related statistically with the needle size, with a greater prevalence in the 14-gauge group on both extemporaneous analysis (P = .019) and definitive analysis (P = .002). The macrometastasis rate was 17% (63 of 377) for the 14-gauge and 3% (12 of 377) for the 16- and 18-gauge needles, respectively. Our preliminary results have suggested that use of a large needle size in CNB does not influence SLN status; thus, preoperative breast biopsy can be considered a safe procedure in the diagnosis of malignant breast lesions. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Business travel-associated illness: a GeoSentinel analysis.

    Science.gov (United States)

    Chen, Lin H; Leder, Karin; Barbre, Kira A; Schlagenhauf, Patricia; Libman, Michael; Keystone, Jay; Mendelson, Marc; Gautret, Philippe; Schwartz, Eli; Shaw, Marc; MacDonald, Sue; McCarthy, Anne; Connor, Bradley A; Esposito, Douglas H; Hamer, Davidson; Wilson, Mary E

    2018-01-01

    Analysis of a large cohort of business travelers will help clinicians focus on frequent and serious illnesses. We aimed to describe travel-related health problems in business travelers. GeoSentinel Surveillance Network consists of 64 travel and tropical medicine clinics in 29 countries; descriptive analysis was performed on ill business travelers, defined as persons traveling for work, evaluated after international travel 1 January 1997 through 31 December 2014. Among 12 203 business travelers seen 1997-2014 (14 045 eligible diagnoses), the majority (97%) were adults aged 20-64 years; most (74%) reported from Western Europe or North America; two-thirds were male. Most (86%) were outpatients. Fewer than half (45%) reported a pre-travel healthcare encounter. Frequent regions of exposure were sub-Saharan Africa (37%), Southeast Asia (15%) and South Central Asia (14%). The most frequent diagnoses were malaria (9%), acute unspecified diarrhea (8%), viral syndrome (6%), acute bacterial diarrhea (5%) and chronic diarrhea (4%). Species was reported for 973 (90%) of 1079 patients with malaria, predominantly Plasmodium falciparum acquired in sub-Saharan Africa. Of 584 (54%) with malaria chemoprophylaxis information, 92% took none or incomplete courses. Thirteen deaths were reported, over half of which were due to malaria; others succumbed to pneumonia, typhoid fever, rabies, melioidosis and pyogenic abscess. Diarrheal illness was a major cause of morbidity. Malaria contributed substantial morbidity and mortality, particularly among business travelers to sub-Saharan Africa. Underuse or non-use of chemoprophylaxis contributed to malaria cases. Deaths in business travelers could be reduced by improving adherence to malaria chemoprophylaxis and targeted vaccination for vaccine-preventable diseases. Pre-travel advice is indicated for business travelers and is currently under-utilized and needs improvement.

  18. Influence of colloid particle profile on sentinel lymph node uptake

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Nunez, Eutimio Gustavo [Radiopharmacy Center, Institute of Energetic and Nuclear Research, Sao Paulo, SP 05508-000 (Brazil)], E-mail: eutimiocu@yahoo.com; Linkowski Faintuch, Bluma; Teodoro, Rodrigo; Pereira Wiecek, Danielle [Radiopharmacy Center, Institute of Energetic and Nuclear Research, Sao Paulo, SP 05508-000 (Brazil); Martinelli, Jose Roberto [Center of Materials Science and Technology, Institute of Energetic and Nuclear Research, Sao Paulo, SP 05508-000 (Brazil); Gomes da Silva, Natanael; Castanheira, Claudia E. [Radiopharmacy Center, Institute of Energetic and Nuclear Research, Sao Paulo, SP 05508-000 (Brazil); Santos de Oliveira Filho, Renato [Faculty of Medicine, Federal University of Sao Paulo, SP 04020-041 (Brazil); Pasqualini, Roberto [CIS bio international, Research and Development, Gif sur Yvette, 91192 (France)

    2009-10-15

    Introduction: Particle size of colloids employed for sentinel lymph node (LN) detection is not well studied. This investigation aimed to correlate particle size and distribution of different products with LN uptake. Methods: All agents (colloidal tin, dextran, phytate and colloidal rhenium sulfide) were labeled with {sup 99m}Tc according to manufacturer's instructions. Sizing of particles was carried out on electron micrographs using Image Tool for Windows (Version 2.0). Biodistribution studies in main excretion organs as well as in popliteal LN were performed in male Wistar rats [30 and 90 min post injection (p.i.)]. The injected dose was 0.1 ml (37 MBq) in the footpad of the left posterior limb. Dynamic images (0-15 min p.i.) as well as static ones (30 and 90 min) were acquired in gamma camera. Results: Popliteal LN was clearly reached by all products. Nevertheless, particle size remarkably influenced node uptake. Colloidal rhenium sulfide, with the smallest diameter (5.1x10{sup -3}{+-}3.9x10{sup -3} {mu}m), permitted the best result [2.72{+-}0.64 percent injected dose (%ID) at 90 min]. Phytate displayed small particles (<15 {mu}m) with favorable uptake (1.02{+-}0.14%ID). Dextran (21.4{+-}12.8 {mu}m) and colloidal tin (39.0{+-}8.3 {mu}m) were less effective (0.55{+-}0.14 and 0.06{+-}0.03%ID respectively). Particle distribution also tended to influence results. When asymmetric, it was associated with biphasic uptake which increased over time; conversely, symmetric distribution (colloidal tin) was consistent with a constant pattern. Conclusion: The results are suggesting that particle size and symmetry may interfere with LN radiopharmaceutical uptake.

  19. Validity of medium-energy collimator for sentinel lymphoscintigraphy imaging

    International Nuclear Information System (INIS)

    Tsushima, Hiroyuki; Yamanaga, Takashi; Shimonishi, Yoshihiro; Kosakai, Kazuhisa; Takayama, Teruhiko; Kizu, Hiroto; Noguchi, Atsushi; Onoguchi, Masahisa

    2007-01-01

    For lymphoscintigraphy to detect sentinel lymph node (SLN) in the breast cancer, the lead shielding of the injection site is often used to avoid artifacts, but the method tends to cover the neighborhood SLN. To exclude this defect, authors developed ME (medium-energy) method where ME collimator and energy setting shifted to its higher region were employed. This paper described the development and validity evaluation of the ME method. Performed were examinations with 3 acrylic phantoms of the injection site (IS), LN and combination of IS+LN (CB): IS was a cylinder, containing 40 MBq of 99m Tc-pertechnetate and LN, a plate with 30 sealed holes having 0.78-400 kBq. CB phantom consisted from LN-simulating holes (each, 40 kBq) placed linearly around the center of IS in H and S directions. Imaging was conducted with 2 kinds of 2-detector gamma camera, FORTE (ADAGA) and DSX rectangular (Sopha Medical Corp.). CB phantom was found optimally visualized by ME collimator at 146, rather than 141, keV. In clinic, 99m Tc-Sn-colloid 40 MBq was given near the tumor of a patient and imaging was done with or without the lead shield with FORTE equipped with low energy high-resolution or ME collimator for their comparison. The present ME method described above set at 146 keV was found to give the image with excellent contrast and without false positive when compared with the lead shield method hitherto. (R.T.)

  20. Reoperative sentinel lymph node biopsy after previous mastectomy.

    Science.gov (United States)

    Karam, Amer; Stempel, Michelle; Cody, Hiram S; Port, Elisa R

    2008-10-01

    Sentinel lymph node (SLN) biopsy is the standard of care for axillary staging in breast cancer, but many clinical scenarios questioning the validity of SLN biopsy remain. Here we describe our experience with reoperative-SLN (re-SLN) biopsy after previous mastectomy. Review of the SLN database from September 1996 to December 2007 yielded 20 procedures done in the setting of previous mastectomy. SLN biopsy was performed using radioisotope with or without blue dye injection superior to the mastectomy incision, in the skin flap in all patients. In 17 of 20 patients (85%), re-SLN biopsy was performed for local or regional recurrence after mastectomy. Re-SLN biopsy was successful in 13 of 20 patients (65%) after previous mastectomy. Of the 13 patients, 2 had positive re-SLN, and completion axillary dissection was performed, with 1 having additional positive nodes. In the 11 patients with negative re-SLN, 2 patients underwent completion axillary dissection demonstrating additional negative nodes. One patient with a negative re-SLN experienced chest wall recurrence combined with axillary recurrence 11 months after re-SLN biopsy. All others remained free of local or axillary recurrence. Re-SLN biopsy was unsuccessful in 7 of 20 patients (35%). In three of seven patients, axillary dissection was performed, yielding positive nodes in two of the three. The remaining four of seven patients all had previous modified radical mastectomy, so underwent no additional axillary surgery. In this small series, re-SLN was successful after previous mastectomy, and this procedure may play some role when axillary staging is warranted after mastectomy.

  1. Sentinel-1 Interferometry from the Cloud to the Scientist

    Science.gov (United States)

    Garron, J.; Stoner, C.; Johnston, A.; Arko, S. A.

    2017-12-01

    Big data problems and solutions are growing in the technological and scientific sectors daily. Cloud computing is a vertically and horizontally scalable solution available now for archiving and processing large volumes of data quickly, without significant on-site computing hardware costs. Be that as it may, the conversion of scientific data processors to these powerful platforms requires not only the proof of concept, but the demonstration of credibility in an operational setting. The Alaska Satellite Facility (ASF) Distributed Active Archive Center (DAAC), in partnership with NASA's Jet Propulsion Laboratory, is exploring the functional architecture of Amazon Web Services cloud computing environment for the processing, distribution and archival of Synthetic Aperture Radar data in preparation for the NASA-ISRO Synthetic Aperture Radar (NISAR) Mission. Leveraging built-in AWS services for logging, monitoring and dashboarding, the GRFN (Getting Ready for NISAR) team has built a scalable processing, distribution and archival system of Sentinel-1 L2 interferograms produced using the ISCE algorithm. This cloud-based functional prototype provides interferograms over selected global land deformation features (volcanoes, land subsidence, seismic zones) and are accessible to scientists via NASA's EarthData Search client and the ASF DAACs primary SAR interface, Vertex, for direct download. The interferograms are produced using nearest-neighbor logic for identifying pairs of granules for interferometric processing, creating deep stacks of BETA products from almost every satellite orbit for scientists to explore. This presentation highlights the functional lessons learned to date from this exercise, including the cost analysis of various data lifecycle policies as implemented through AWS. While demonstrating the architecture choices in support of efficient big science data management, we invite feedback and questions about the process and products from the InSAR community.

  2. SENTINEL LYMPH NODE CONCEPT IN DIFFERENTIATED THYROID CANCER

    Directory of Open Access Journals (Sweden)

    Markovic Ivan

    2014-12-01

    Full Text Available Introduction: Differentiated thyroid carcinoma (DTC account up to 90% of all thyroid malignacies, and represents the most common malignant tumors of endocrine system. The incidence of papillary thyroid carcinoma (PTC, especially small tumors is rapidly increasing during past three decades. At the time of diagnosis, the incidence of lymph node metastases (LNM ranges from 80 to 90%. During the last 15 years, LNM were recognized as bad prognostic factor for both local-regional relapse (LRR and cancer specific survival. There is general agreement that neck dissections are indicated in cases of clinically apparent LNM. The subject of the current controversy is the surgical treatment of occult LNM that remain unrecognized on preoperative diagnosis (cN0. The extent of operations of the lymph nodes ranges from “wait and see” so-called “Western school” principle substantiated the role of applying ablative I131therapy and frequency peroperative complications (recurrent laryngeal nerve injury and hypoparathyroidism, especially for less experienced teams to mutual prophylactic dissection of the central and lateral compartments so-called “Japanese school” due to the limited use of radioactive iodine therapy and significantly lower operating morbidity if dissetion was done during primary operation. Despite high prevalence of occult LNM, existing controversies regarding diagnosis, longterm prognostic impact and extent of lymph node surgery, motivated some authors to apply consept of sentinel lymph node biopsy (SLNb in DTC, taking into account excellent results of SLN concept in breast cancer and skin melanoma. This review presents the summarized results of relevant studies and three meta-analysis of accuracy and applicability of SLN concept in patients with differentiated thyroid carcinoma.

  3. Preliminary evaluation of intraoperative gamma probe detection of the sentinel node

    Energy Technology Data Exchange (ETDEWEB)

    Sierralta, M P; Jofre, M J [Nuclear Medicine Department, Military Hospital, Santiago (Chile); Iglesis, R; Schwartz, R; Gomez, L; Velez, R [Surgery Department, Military Hospital, Santiago (Chile); Sandoval, R [Pathology Department, Military Hospital, Santiago (Chile)

    2002-09-01

    Introduction: The resurgence of the lymphoscintigraphy with the sentinel node concept and the availability of the intraoperative gamma probe have been proposed to avoid the morbidity of an unnecessary regional node dissection. The aim of the study was to evaluate the intraoperative gamma probe use after lymphoscintigraphy for the localization of the sentinel node. Material and methods: Twenty-nine patients were studied, 18 females (62%), mean age 60 {+-} 19 y.o. (range 24-86 y.o.) at the Military Hospital Nuclear Medicine Department. The reference diagnoses were 66% malignant melanoma, 21 % breast cancer, 10 % head and neck cancer and 3% vulvae cancer. Lymphoscintigraphs were performed with Tc99m-Dextran injected intradermally in four points around the primary lesion or around the biopsy site (for melanoma 500 microCi each one; for breast and head and neck 200 microCi each one). Afterwards, dynamic images were taken, followed by intraoperative gamma probe investigations in order to localize and remove the sentinel node. Additionally, isosulfan blue was injected before the surgery was made. Results: Lymphoscintigraphy was positive to detect sentinel node(s) in 20 patients (69%). During the surgery, 40 sentinel nodes were detected. In 33 cases, the intraoperative gamma probe was performed, of which 88 % were radioactives. In 35 nodes, the isosulfan blue was injected, of which 80 % were dyed. The correlation between both techniques was 75 %. The histology study of 37 samples demonstrated that 86% (n=32) were truly ganglionar nodes. Conclusion: The intraoperative gamma probe after lymphoscintigraphy is a useful technique for the localization of the sentinel node.

  4. Preliminary evaluation of intraoperative gamma probe detection of the sentinel node

    International Nuclear Information System (INIS)

    Sierralta, M.P.; Jofre, M.J.; Iglesis, R.; Schwartz, R.; Gomez, L.; Velez, R.; Sandoval, R.

    2002-01-01

    Introduction: The resurgence of the lymphoscintigraphy with the sentinel node concept and the availability of the intraoperative gamma probe have been proposed to avoid the morbidity of an unnecessary regional node dissection. The aim of the study was to evaluate the intraoperative gamma probe use after lymphoscintigraphy for the localization of the sentinel node. Material and methods: Twenty-nine patients were studied, 18 females (62%), mean age 60 ± 19 y.o. (range 24-86 y.o.) at the Military Hospital Nuclear Medicine Department. The reference diagnoses were 66% malignant melanoma, 21 % breast cancer, 10 % head and neck cancer and 3% vulvae cancer. Lymphoscintigraphs were performed with Tc99m-Dextran injected intradermally in four points around the primary lesion or around the biopsy site (for melanoma 500 microCi each one; for breast and head and neck 200 microCi each one). Afterwards, dynamic images were taken, followed by intraoperative gamma probe investigations in order to localize and remove the sentinel node. Additionally, isosulfan blue was injected before the surgery was made. Results: Lymphoscintigraphy was positive to detect sentinel node(s) in 20 patients (69%). During the surgery, 40 sentinel nodes were detected. In 33 cases, the intraoperative gamma probe was performed, of which 88 % were radioactives. In 35 nodes, the isosulfan blue was injected, of which 80 % were dyed. The correlation between both techniques was 75 %. The histology study of 37 samples demonstrated that 86% (n=32) were truly ganglionar nodes. Conclusion: The intraoperative gamma probe after lymphoscintigraphy is a useful technique for the localization of the sentinel node

  5. Design considerations, architecture, and use of the Mini-Sentinel distributed data system.

    Science.gov (United States)

    Curtis, Lesley H; Weiner, Mark G; Boudreau, Denise M; Cooper, William O; Daniel, Gregory W; Nair, Vinit P; Raebel, Marsha A; Beaulieu, Nicolas U; Rosofsky, Robert; Woodworth, Tiffany S; Brown, Jeffrey S

    2012-01-01

    We describe the design, implementation, and use of a large, multiorganizational distributed database developed to support the Mini-Sentinel Pilot Program of the US Food and Drug Administration (FDA). As envisioned by the US FDA, this implementation will inform and facilitate the development of an active surveillance system for monitoring the safety of medical products (drugs, biologics, and devices) in the USA. A common data model was designed to address the priorities of the Mini-Sentinel Pilot and to leverage the experience and data of participating organizations and data partners. A review of existing common data models informed the process. Each participating organization designed a process to extract, transform, and load its source data, applying the common data model to create the Mini-Sentinel Distributed Database. Transformed data were characterized and evaluated using a series of programs developed centrally and executed locally by participating organizations. A secure communications portal was designed to facilitate queries of the Mini-Sentinel Distributed Database and transfer of confidential data, analytic tools were developed to facilitate rapid response to common questions, and distributed querying software was implemented to facilitate rapid querying of summary data. As of July 2011, information on 99,260,976 health plan members was included in the Mini-Sentinel Distributed Database. The database includes 316,009,067 person-years of observation time, with members contributing, on average, 27.0 months of observation time. All data partners have successfully executed distributed code and returned findings to the Mini-Sentinel Operations Center. This work demonstrates the feasibility of building a large, multiorganizational distributed data system in which organizations retain possession of their data that are used in an active surveillance system. Copyright © 2012 John Wiley & Sons, Ltd.

  6. Manatees as sentinels of marine ecosystem health: are they the 2000-pound canaries?

    Science.gov (United States)

    Bonde, R.K.; Aguirre, A.A.; Powell, J.

    2004-01-01

    The order Sirenia is represented by three species of manatees and one species of dugong distributed in tropical and subtropical regions of the world and considered vulnerable to extinction. The sentinel species concept is useful to identify indicators of the environment and may reflect the quality of health in marine ecosystems. The single species approach to evaluate ecological health may provide a series of “snap shots” of environmental changes to determine if animal, human, or ecosystem health may be affected. Under this concept, marine vertebrates may be good integrators of changes over space and time, and excellent sentinels of ecosystem health. Based on their life history, manatees may or may not be ideal sentinels, as they are robust, long-lived species and appear remarkably resilient to natural disease and the effects of human-related injury and trauma. These characteristics might be the result of an efficient and responsive immune system compared to other marine mammals. Although relatively immune to infectious agents, manatees face other potentially serious threats, including epizootic diseases and pollution while in large aggregations. Manatees can serve as excellent sentinels of harmful algal blooms due to their high sensitivity, specifically to brevetoxicosis, which has caused at least two major die-offs in recent times. Threats to manatees worldwide, such as illegal hunting and boat collisions, are increasing. Habitat is being lost at an alarming rate and the full effects of uncontrolled human population growth on the species are unknown. The manatee may serve as a sentinel species, prognosticating the deleterious effects of unhealthy marine and aquatic ecosystems on humans. We have identified a number of critical research needs and opportunities for transdisciplinary collaboration that could help advance the use of the sentinel species concept in marine ecosystem health and monitoring of disease emergence using our knowledge on these magnificent

  7. Histological pattern of Merkel cell carcinoma sentinel lymph node metastasis improves stratification of Stage III patients.

    Science.gov (United States)

    Ko, Jennifer S; Prieto, Victor G; Elson, Paul J; Vilain, Ricardo E; Pulitzer, Melissa P; Scolyer, Richard A; Reynolds, Jordan P; Piliang, Melissa P; Ernstoff, Marc S; Gastman, Brian R; Billings, Steven D

    2016-02-01

    Sentinel lymph node biopsy is used to stage Merkel cell carcinoma, but its prognostic value has been questioned. Furthermore, predictors of outcome in sentinel lymph node positive Merkel cell carcinoma patients are poorly defined. In breast carcinoma, isolated immunohistochemically positive tumor cells have no impact, but in melanoma they are considered significant. The significance of sentinel lymph node metastasis tumor burden (including isolated tumor cells) and pattern of involvement in Merkel cell carcinoma are unknown. In this study, 64 Merkel cell carcinomas involving sentinel lymph nodes and corresponding immunohistochemical stains were reviewed and clinicopathological predictors of outcome were sought. Five metastatic patterns were identified: (1) sheet-like (n=38, 59%); (2) non-solid parafollicular (n=4, 6%); (3) sinusoidal, (n=11, 17%); (4) perivascular hilar (n=1, 2%); and (5) rare scattered parenchymal cells (n=10, 16%). At the time of follow-up, 30/63 (48%) patients had died with 21 (33%) attributable to Merkel cell carcinoma. Patients with pattern 1 metastases had poorer overall survival compared with patients with patterns 2-5 metastases (P=0.03), with 22/30 (73%) deaths occurring in pattern 1 patients. Three (10%) deaths occurred in patients showing pattern 5, all of whom were immunosuppressed. Four (13%) deaths occurred in pattern 3 patients and 1 (3%) death occurred in a pattern 2 patient. In multivariable analysis, the number of positive sentinel lymph nodes (1 or 2 versus >2, PMerkel cell carcinoma, the pattern of sentinel lymph node involvement provides important prognostic information and utilizing this data with other clinicopathological features facilitates risk stratification of Merkel cell carcinoma patients who may have management implications.

  8. Comparison of Landsat-8 and Sentinel-2A reflectance and normalized difference vegetation index

    Science.gov (United States)

    Zhang, H.; Roy, D. P.; Yan, L.; Li, Z.; Huang, H.

    2017-12-01

    The moderate spatial resolution satellite data from the polar-orbiting Landsat-8 (launched 2013) and Sentinel-2A (launched 2015) sensors provide 10 m to 30 m multi-spectral global coverage with a better than 5-day revisit. Although a national laboratory traceable cross-calibration comparison of the Landsat-8 Operational Land Imager (OLI) and the Sentinel-2A MultiSpectral Instrument (MSI) was undertaken pre-launch, there are a number of other sensor differences, notably due to spectral, spatial and angular differences. To examine these in a comprehensive way, Landsat-8 and Sentinel-2A data for approximately 20° × 10° of southern Africa acquired in the summer (January to March) and winter (July to September) of 2016 were compared. Only Landsat-8 and Sentinel-2A observations acquired within one-day apart were considered. The sensor data were registered and then each orbit projected into 30 m fixed global Web Enabled Landsat Data (GWELD) tiles defined in the MODIS sinusoidal equal area projection. Only corresponding sensor observations of each 30 m tile pixel that were flagged as cloud and snow-free, unsaturated, and that had no significant change in their one day separation, were compared. Both the Landsat-8 and Sentinel-2A data were atmospherically corrected using the Landsat Surface Reflectance Code (LaSRC) and were also corrected to nadir BRDF adjusted reflectance (NBAR). Top of atmosphere and surface reflectance for the spectrally corresponding visible, near infrared and shortwave infrared OLI and MSI bands, and derived normalized difference vegetation index (NDVI), were compared and their differences quantified using regression analyses. The resulting statistical transformations may be used to improve the consistency between the Landsat-8 OLI and Sentinel-2A MSI data. The importance and sensitivity of the results to correct filtering, atmospheric correction and adjustment to NBAR is demonstrated.

  9. Upper airway evaluation

    International Nuclear Information System (INIS)

    Hoffman, E.A.; Gefter, W.B.; Schnall, M.; Nordberg, J.; Listerud, J.; Lenkinski, R.E.

    1988-01-01

    The authors are evaluating upper-airway sleep disorders with magnetic resonance (MR) imaging and x-ray cine computed tomography (CT). Fixed structural anatomy is visualized with multisection spin-echo MR imaging, the dynamic component with cine CT. Unique aspects of the study are described in this paper

  10. The Surveillance and On-demand Sentinel-1 SBAS Services on the Geohazards Exploitation Platforms

    Science.gov (United States)

    Casu, F.; de Luca, C.; Zinno, I.; Manunta, M.; Lanari, R.

    2017-12-01

    The Geohazards Exploitation Platform (GEP) is an ESA R&D activity of the EO ground segment to demonstrate the benefit of new technologies for large scale processing of EO data. GEP aims at providing on-demand processing services for specific user needs, as well as systematic processing services to address the need of the geohazards community for common information layers and, finally, to integrate newly developed processors for scientists and other expert users. In this context, a crucial role is played by the recently launched Sentinel-1 (S1) constellation that, with its global acquisition policy, has flooded the scientific community with a huge amount of data acquired over large part of the Earth on a regular basis (down to 6-days with both Sentinel-1A and 1B passes). The Sentinel-1 data, as part of the European Copernicus program, are openly and freely accessible, thus fostering their use for the development of automated and systematic tools for Earth surface monitoring. In particular, due to their specific SAR Interferometry (InSAR) design, Sentinel-1 satellites can be exploited to build up operational services for the easy and rapid generation of advanced InSAR products useful for risk management and natural hazard monitoring. In this work we present the activities carried out for the development, integration, and deployment of two SBAS Sentinel-1 services of CNR-IREA within the GEP framework, namely the Surveillance and On-demand services. The Surveillance service consists on the systematic and automatic processing of Sentinel-1 data over selected Areas of Interest (AoI) to generate updated surface displacement time series via the SBAS-InSAR algorithm. We built up a system that is automatically triggered by every new Sentinel-1 acquisition over the AoI, once it is available on the S1 catalogue. Then, the system processes the new acquisitions only, thus saving storage space and computing time. The processing, which relies on the Parallel version of the SBAS (P

  11. Mulig forbedret behandling af kolorektal cancer med sentinel lymph node-diagnostik

    DEFF Research Database (Denmark)

    Burgdorf, Stefan Kobbelgaard; Eriksen, Jens Ravn; Gögenur, Ismail

    2014-01-01

    Possibly improved treatment of colorectal cancer by sentinel lymph node mapping Prognosis for colorectal cancer is dependent on radical surgical intervention. Chemotherapy in patients with advanced disease has improved the survival. A considerable proportion of the patients going through radical...... surgery will subsequently relapse. Adjuvant chemotherapy is reserved for patients with lymph node metastases, why undetected malignant lymph nodes will result in understaging and exclusion from the possible benefit of adjuvant chemotherapy. With sentinel lymph node mapping it may be possible to detect...... and resect more malignant lymph node and maybe even avoid extensive resections....

  12. Sentinel lymph node and its applications in cancer. Review of literature

    International Nuclear Information System (INIS)

    Leon A, L.; Vigil R, C.; Velarde G, R.; Abugattas S, J.; Leon R, M.; Caceres G, E.; Cano P, R.; Morales G, R.; Aguilar R, C.

    2001-01-01

    In the human body, the lymph nodes groups like in the groin, axilla, neck and others regions, receive the lymphatic drainage from a determined corporal territory, and the first node to receive it is called the sentinel node and as the name suggest, it is the most likely node to contain metastases if present; in the axilla the sentinel node is usually localized in level I. The presence of regional lymph node involvement remains the most reliable prognostic factor and provides accurate nodal staging for woman with epithelial cancers. The most commonly use indicator of prognosis for patients with operable carcinoma of the breast is the histological presence or absence of axillary lymph node metastases. The sentinel node biopsy is a new procedure composed of two steps: the first is the lymphatic mapping where the sentinel node can be identified in the preoperative period by lymphoscintigraphy, and in the operating room by injection of a vital blue dye, and with technetium labeled sulfur colloid injected into the same area as the vital blue dye or in place of the blue dye. In the second step the extracted and a rigorous assessment of the accuracy by pathological examination. Multiple studies have showed that if the sentinel lymph node is negative for metastatic disease, the remaining lymph nodes are also likely to be negative. The value of the sentinel lymph node biopsy is based in the pathologic diagnosis, when it is negative it is possible to avoid axillary dissection. The technique of identification of sentinel lymph node is applied to different types of cancers and distinct localizations, in the penis, malignant melanoma, breast, head and neck (oral cavity, epidermoid carcinoma, malignant melanoma), vulva, gastric, colorectal, 'non small cell lung cancer' and for merkel cell carcinoma. This publication regarding the sentinel lymph node technique and its applications in cancer, represents the routine followed in the Department of Breast Bone and Mixed Tumours of the

  13. Basic numerical study on gap influence of residual stress and distortion during high-brightness laser butt welding

    International Nuclear Information System (INIS)

    Serizawa, Hisashi; Mori, Daiki; Murakawa, Hidekazu

    2013-01-01

    High-brightness laser such as fiber laser or disk laser is expected to minimize the total heat input energy in welding due to its high beam quality, and the welding residual stress and distortion also seem to be reduced as a result. However, the diameter of high-brightness laser beam is less than 0.6 mm and it is difficult to set the beam position to contact face between two parts because in general there would be a gap due to quality of parts. In this study, in order to reveal the effect of gap on the residual stress and the welding distortion during fiber laser welding, the butt welding of two plates were examined through the thermal elastic-plastic analysis with a new gap element. From the result of thermal analyses, it was found that the homogeneous ellipsoid body could be applicable to model the shape of heat source for the fiber laser and the gap width would not influence the penetration shape when the gap width was changed from 0.1 to 0.25 mm. In addition, the elastic-plastic analyses indicated that the transverse shrinkage slightly increased with increasing the gap width, while this shrinkage without gap was much smaller than that with gap. Also, it was revealed that the welding speed largely affects both the welding residual stress and distortion. Moreover, it was found that the residual stress was almost independent of the jig position, while the position of fixtures slightly affected the transverse shrinkage. (author)

  14. Butt Welding of 2205/X65 Bimetallic Sheet and Study on the Inhomogeneity of the Properties of the Welded Joint

    Science.gov (United States)

    Gou, Ning-Nian; Zhang, Jian-Xun; Wang, Jian-Long; Bi, Zong-Yue

    2017-04-01

    The explosively welded 2205 duplex stainless steel/X65 pipe steel bimetallic sheets were butt jointed by multilayer and multi-pass welding (gas tungsten arc welding for the flyer and gas metal arc welding for the transition and parent layers of the bimetallic sheets). The microstructure and mechanical properties of the welded joint were investigated. The results showed that in the thickness direction, microstructure and mechanical properties of the welded joint exhibited obvious inhomogeneity. The microstructures of parent filler layers consisted of acicular ferrite, widmanstatten ferrite, and a small amount of blocky ferrite. The microstructure of the transition layer and flyer layer consisted of both austenite and ferrite structures; however, the transition layer of weld had a higher volume fraction of austenite. The results of the microhardness test showed that in both weld metal (WM) and heat-affected zone (HAZ) of the parent filler layers, the average hardness decreased with the increasing (from parent filler layer 1 to parent filler layer 3) welding heat input. The results of hardness test also indicated that the hardness of the WM and the HAZ for the flyer and transition layers was equivalent. The tensile test combined with Digital Specklegram Processing Technology demonstrated that the fracturing of the welded joint started at the HAZ of the flyer, and then the fracture grew toward the base metal of the parent flyer near the parent HAZ. The stratified impact test at -5 °C showed that the WM and HAZ of the flyer exhibited lower impact toughness, and the fracture mode was ductile and brittle mixed fracture.

  15. Identification of the sentinel lymph node in patients with malignant melanoma: what are the reasons for mistakes?

    International Nuclear Information System (INIS)

    Vidal-Sicart, Sergi; Pons, Francesca; Puig, Susana; Vilalta, Antonio; Palou, J.M.; Castel, Teresa; Ortega, Marisa; Martin, Francisco; Rull, Ramon

    2003-01-01

    Scintigraphic identification of the sentinel lymph node is achievable in nearly all patients with malignant melanoma. However, in a very small number of cases the sentinel node fails to be detected, and sometimes recurrence appears during follow-up in patients who had previously tested negative for metastatic disease. The purpose of this study was to review our experience in order to isolate the reasons for erroneous sentinel lymph node identification. The evaluation involved 435 consecutive malignant melanoma patients with AJCC stages I and II (clinically negative nodes) and Breslow thickness >0.76 mm. Lymphoscintigraphy was performed the day before surgery by intradermal administration of technetium-99m labelled nanocolloid. Dynamic and static images were obtained. The sentinel node was intraoperatively identified with the aid of patent blue dye and a hand-held gamma probe. After removal, routine histopathological examination with haematoxylin-eosin (H-E) and immunohistochemistry with S 100 and HMB45 (IHC) were performed. In those patients who developed regional recurrences during follow-up, sentinel nodes were further evaluated by reverse transcriptase-polymerase chain reaction (RT-PCR). Lymphoscintigraphy visualised at least one sentinel node in 434 out of 435 patients (99.8%). Uptake in in-transit sentinel lymph nodes was observed in 32 patients (7.4%). During surgery, localisation and removal of sentinel nodes was successful in 430/435 patients (98.8%). A total of 790 sentinel lymph nodes were harvested, with a mean of 1.8 per patient. Routine histopathological examination with H-E or IHC revealed metastatic disease in 72 patients (16.8%). During a mean follow-up of 26 months, seven of those patients with a negative sentinel node developed regional lymph node metastases. In five of them RT-PCR was positive for micrometastases within the sentinel node. In conclusion, erroneous sentinel lymph node identification can be due to changes in the surgical team

  16. Upper urinary tract tumors

    DEFF Research Database (Denmark)

    Gandrup, Karen L; Nordling, Jørgen; Balslev, Ingegerd

    2014-01-01

    BACKGROUND: Computed tomography urography (CTU) is used widely in the work-up of patients with symptoms of urinary tract lesions. Preoperative knowledge of whether a tumor is invasive or non-invasive is important for the choice of surgery. So far there are no studies about the distinction...... of invasive and non-invasive tumors in ureter and renal pelvis based on the enhancement measured with Hounsfield Units. PURPOSE: To examine the value of CTU using split-bolus technique to distinguish non-invasive from invasive urothelial carcinomas in the upper urinary tract. MATERIAL AND METHODS: Patients...... obtained at CTU could distinguish between invasive and non-invasive lesions. No patients had a CTU within the last year before the examination that resulted in surgery. CONCLUSION: A split-bolus CTU cannot distinguish between invasive and non-invasive urothelial tumors in the upper urinary tract...

  17. Modeling behavioral thermoregulation in a climate change sentinel.

    Science.gov (United States)

    Moyer-Horner, Lucas; Mathewson, Paul D; Jones, Gavin M; Kearney, Michael R; Porter, Warren P

    2015-12-01

    , mechanistic predictions and empirical observations were congruent. This research is unique in providing both an empirical and mechanistic description of the effects of temperature on a mammalian sentinel of climate change, the American pika. Our results suggest that previously underinvestigated characteristics, specifically fur properties and body size, may play critical roles in pika populations' response to climate change. We also demonstrate the potential importance of considering behavioral thermoregulation and microclimate variability when predicting animal responses to climate change.

  18. The Ocean Surface Topography SENTINEL-6/JASON-CS Mission

    Science.gov (United States)

    Cullen, R.

    2015-12-01

    The Sentinel-6/Jason-CS mission will consist of 2 spacecraft and will be the latest in a series of ocean surface topography missions that will span nearly three decades. They follow the altimeters on- board TOPEX/Poseidon through to Jason-3 (expected March 2015). Jason-CS will continue to fulfil objectives of the reference series whilst introducing a major enhancement in capability providing the operational and science oceanographic community with the state of the art in terms of platform, measurement instrumentation design thus securing optimal operational and science data return. The programme is a part of the EC Copernicus initiative, whose objective is to support Europe's goals regarding sustainable development and global governance of the environment by providing timely and quality data, information, services and knowledge. The programme brings together: ESA for development, procurement & early orbit activities; EUMETSAT for mission management, ground segment, flight ops, contributing funding of the 1st satellite and participation in funding for the 2nd satellite; NASA for the US payload and launcher procurement in addition to funding US science opportunities; EC for funding the operations and participation in funding (with EUMETSAT) for the 2nd satellite; NOAA are expected to provide US ground stations & operations services; CNES for mission expertise and provision of the POD service. The consortium plan to procure 2 satellites with the 1st planned for launch readiness in the 1st half of 2020 with the 2nd satellite 5 years later. The first major commitment to funding was given by the ESA member states that approved the programme in June 2014 and in addition the European Commission funding is also fully secure. The design is based on a platform derived from CryoSat-2 adjusted to the specific requirements of the higher orbit. The principle payload instrument is a high precision Ku/C band radar altimeter with retrieval of geophysical parameters (surface

  19. The Ocean Surface Topography JASON-CS/SENTINEL-6 Mission

    Science.gov (United States)

    Cullen, R.; Francis, R.

    2014-12-01

    The Jason-CS/Sentinel-6 programme will consist of 2 spacecraft and will be the latest in a series of ocean surface topography missions that will span nearly three decades. They follow the altimeters on-board TOPEX/Poseidon through to Jason-3 (expected March 2015). Jason-CS will continue to fulfil objectives of the reference series whilst introducing a major enhancement in capability providing the operational and science oceanographic community with the state of the art in terms of platform, measurement instrumentation design thus securing optimal operational and science data return. The programme is a part of the EC Copernicus initiative, whose objective is to support Europe's goals regarding sustainable development and global governance of the environment by providing timely and quality data, information, services and knowledge. The programme brings together: ESA for development, procurement & early orbit activities; EUMETSAT for mission management, ground segment, flight ops, contributing funding of the 1st satellite and participation in funding for the 2nd satellite; NOAA for US payload instruments, launcher, ground stations & operations; NASA for developing the US payload, launcher procurement and funding US science; EU for funding the operations and participation in funding (with EUMETSAT) for the 2nd satellite; CNES for mission expertise and provision of POD. The consortium plan to procure 2 satellites with the 1st planned for launch readiness in the 1st half of 2020 with the 2nd satellite 5 years later. The first major commitment to funding was given by the ESA member states that approved the programme in June 2014 and in addition the European Union funding is also secure. The design will be based on a platform derived from CryoSat-2 but adjusted to the specific requirements of the higher orbit. The principle payload instrument is a high precision Ku/C band radar altimeter with retrieval of geophysical parameters (surface elevation, wind speed and SWH) from

  20. Lymphatic mapping and sentinel node biopsy in early stage melanoma: study of the first 100 cases in Institut Gustave Roussy

    International Nuclear Information System (INIS)

    Buffard, V.; Duvillard, P.; Mamelle, G.; Lumbroso, J.; Ricard, M.; Kolb, F.; Sleilati, F.; Spatz, A.

    2005-01-01

    Introduction: We report the data of the first 100 patients who underwent sentinel lymph node biopsy (SLND) in our institution using lymphoscintigraphy only. Patients and methods: From 1998 to 2000, 100 consecutive patients (53 men and 47 women) with stage I or II melanoma (mean Breslow: 3.11 mm) underwent a SLND. Localisation of the sentinel node was performed by preoperative lymphoscintigraphy and hand held gamma probe detection. The sentinel node was examined by routine histology and immunohistochemistry for PS100 and HMB-45. If the sentinel node contained tumor cells, a complete lymphadenectomy was performed. Results: Lymphoscintigraphy was performed for 97 patients. The SLN was identified in 97% of cases (94/97) and excised in 95% of cases (92/97). The rate of SLN metastasis was 19/92 patients (21%), correlated with Breslow index ( 4 mm: 46%). A mean number of 1.81 lymph node per patient was analysed. The mean follow-up was 26 months with a relapse in 14 patients, 5 of them having a metastatic sentinel node. Three patients had a recurrence at the site of the SLND although they had initially a negative sentinel node. Conclusion: The identification and metastatic rates of sentinel nodes are similar to those of the literature. More studies are needed to determine whether lymphoscintigraphy alone is efficient for successful SLND in melanoma. (author)

  1. Preventing childhood obesity: the sentinel site for obesity prevention in Victoria, Australia.

    Science.gov (United States)

    Bell, A Colin; Simmons, Anne; Sanigorski, Andrea M; Kremer, Peter J; Swinburn, Boyd A

    2008-12-01

    In spite of greater awareness of the need for action to reduce obesity, the evidence on sustainable community approaches to prevent childhood and adolescent obesity is surprisingly sparse. This paper describes the design and methodological components of the Sentinel Site for Obesity Prevention, a demonstration site in the Barwon-South West region of Victoria, Australia, that aims to build the programs, skills and evidence necessary to attenuate and eventually reverse the obesity epidemic in children and adolescents. The Sentinel Site for Obesity Prevention is based on a partnership between the region's university (Deakin University) and its health, education and local government agencies. The three basic foundations of the Sentinel Site are: multi-strategy, multi-setting interventions; building community capacity; and undertaking program evaluations and population monitoring. Three intervention projects have been supported that cover different age groups (preschool: 2-5 years, primary school: 5-12 years, secondary school: 13-17 years), but that have many characteristics in common including: community participation and ownership of the project; an intervention duration of at least 3 years; and full evaluations with impact (behaviours) and outcome measures (anthropometry) compared with regionally representative comparison populations. We recommend the Sentinel Site approach to others for successfully building evidence for childhood obesity prevention and stimulating action on reducing the epidemic.

  2. Interest of the technical detection of the sentinel node applied to uterine cancers: about three cases

    International Nuclear Information System (INIS)

    Ech charraq, I.; Ben Rais, N.; Ech charra, I.; Albertini, A.F.

    2009-01-01

    Introduction The sentinel node technique (S.N.) was proposed in cervical cancers in order to optimise the diagnosis of metastases and the lymphatic micrometastases in the early stages while avoiding useless wide clearings out. The identification of this node is done by injection of a dye and/or a radioactive colloid and its ablation for pathological examination. Patients and methods We report the case of three patients followed for a uterine cancer having benefited from a lymphoscintigraphy before surgery. During the surgical procedure, the detection of the sentinel node was carried out after cervical injection of blue dye and using a gamma detection probe. Results The lymphoscintigraphy was positive for two cases with a positive detection for the three cases during the operation. The pathological study revealed a node metastasis for one case. The technical of the sentinel node applied to uterine cancers appears realizable essentially for uterine cancers of early stage (I). However the risk of false negative can be observed in advanced cancer (III), as it is the case of our patient having a negative lymphoscintigraphy. Conclusion The nuclear medicine is important in the detection of the sentinel node of various cancers, uterine cancer included, thus allowing an appropriate cardiologic management. (authors)

  3. Reasons for failure to identify positive sentinel nodes in breast cancer patients with significant nodal involvement

    NARCIS (Netherlands)

    de Kanter, A. Y.; Menke-Pluijmers, M. B. E.; Henzen-Logmans, S. C.; van Geel, A. N.; van Eijck, C. J. H.; Wiggers, T.; Eggermont, A. M. M.

    Aim: To analyse causes of failure of sentinel node (SN) procedures in breast cancer patients and assess the role of pre-operative ultrasound examination of the axilla. Methods: In 138 consecutive clinically node negative breast cancer patients with the primary turnout in situ a SN procedure with

  4. Preliminary experiences with sentinel lymph node detection in cases of vulvar malignancy

    International Nuclear Information System (INIS)

    Zambo, Katalin; Schmidt, Erzsebet; Dehghani, Babak; Hartmann, Tamas; Bodis, Jozsef; Kornya, Laszlo; Tinneberg, Hans Rudolf

    2002-01-01

    Lymph node status is the most important prognostic factor in vulvar malignancy. The aim of this pilot study was to explore the clinical significance of radionuclide lymphoscintigraphy in the management of vulvar neoplasms. Eight patients with squamous cell carcinoma and two patients with malignant melanoma of the vulva were studied with 100 MBq technetium-99m nanocolloid (Sentiscint, OSSKI, Budapest) 1 day before surgery. The location of the sentinel lymph node was checked by a single-head gamma camera-computer system (MB 9200, Mediso, Budapest). Vulvectomy with bilateral inguinofemoral lymphadenectomy was performed in each case. At lymphadenectomy, the sentinel lymph node was separately removed and histologically studied. Three of the ten patients had positive sentinel lymph nodes (micrometastasis). Five months later one of them had local recurrence of the vulvar cancer, and another had inguinal recurrence of the tumour 6 months postoperatively; the third patient was operated on only recently. Our preliminary results are impressive and suggest that lymphoscintigraphy is an easy and reliable method for detection of the sentinel lymph node in vulvar malignancy. (orig.)

  5. EANM-EORTC general recommendations for sentinel node diagnostics in melanoma

    DEFF Research Database (Denmark)

    Chakera, Annette H; Hesse, Birger; Burak, Zeynep

    2009-01-01

    -draining sentinel lymph nodes. If specific recommendations given cannot be based on evidence from original, scientific studies, referral is given to "general consensus" and similar expressions. The recommendations are designed to assist in the practice of referral to, performance, interpretation and reporting...

  6. The Use of Sentinel-1 Time-Series Data to Improve Flood Monitoring in Arid Areas

    Directory of Open Access Journals (Sweden)

    Sandro Martinis

    2018-04-01

    Full Text Available Due to the similarity of the radar backscatter over open water and over sand surfaces a reliable near real-time flood mapping based on satellite radar sensors is usually not possible in arid areas. Within this study, an approach is presented to enhance the results of an automatic Sentinel-1 flood processing chain by removing overestimations of the water extent related to low-backscattering sand surfaces using a Sand Exclusion Layer (SEL derived from time-series statistics of Sentinel-1 data sets. The methodology was tested and validated on a flood event in May 2016 at Webi Shabelle River, Somalia and Ethiopia, which has been covered by a time-series of 202 Sentinel-1 scenes within the period June 2014 to May 2017. The approach proved capable of significantly improving the classification accuracy of the Sentinel-1 flood service within this study site. The Overall Accuracy increased by ~5% to a value of 98.5% and the User’s Accuracy increased by 25.2% to a value of 96.0%. Experimental results have shown that the classification accuracy is influenced by several parameters such as the lengths of the time-series used for generating the SEL.

  7. Sentinel 2: implementation of the means and methods for the CAL/VAL commissioning phase

    Science.gov (United States)

    Trémas, Thierry L.; Déchoz, Cécile; Lacherade, Sophie; Nosavan, Julien; Petrucci, Beatrice; Martimort, P.; Isola, Claudia

    2013-10-01

    In partnership with the European Commission and in the frame of the Copernicus program, the European Space Agency (ESA) is developing the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. Sentinel-2 will offer a unique combination of global coverage with a wide field of view (290km), a high revisit (5 days with two satellites), a high resolution (10m, 20m and 60m) and multi-spectral imagery (13 spectral bands in visible and shortwave infra-red domains). The first satellite is planned to be launched in late 2014. In this context, the Centre National d'Etudes Spatiales (CNES) supports ESA to insure the cal/val commissioning phase. This paper provides first, an overview of the Sentinel-2 system and the image products delivered by the ground processing. Then the paper will present the ground segment, presently under preparation at CNES, and the various devices that compose it : the GPP in charge of producing the level 1 files, the "radiometric unit" that processes sensitivity parameters, the "geometric unit" in charge of fitting the images on a reference map, MACCS that will produce Level 2A files (computing reflectances at the Bottom of Atmosphere) and the TEC-S2 that will coordinate all the previous software and drive a database in which will be gather the incoming Level 0 files and the processed Level 1 files.

  8. Vulvar melanoma - Is there a role for sentinel lymph node biopsy?

    NARCIS (Netherlands)

    de Hullu, JA; Hollema, H; Hoekstra, HJ; Piers, DA; Mourits, MJE; Aalders, JG; van der Zee, AGJ

    2002-01-01

    BACKGROUND. The objective of this study was to evaluate the author's recent, preliminary experience with the sentinel lymph node procedure in patient with vulvar melanoma and to compare this experience with treatment and follow-up of patients with vulvar melanomas who were treated previously at

  9. Sentinel node localization in breast cancer patients using intradermal dye injection

    DEFF Research Database (Denmark)

    Ilum, Lars; Bak, Martin; Olsen, K E

    2000-01-01

    -sectioning and immunohistochemical staining for cytokeratin. In one case a benign epithelial inclusion was found. The sentinel node was false negative in 9.1% of cases. The consensus from the literature is that the best results are achieved using a combination of dye and isotopic techniques....

  10. Iatrogenic displacement of tumor cells to the sentinel node after surgical excision in primary breast cancer

    DEFF Research Database (Denmark)

    Tvedskov, Tove F; Jensen, Maj-Britt; Kroman, Niels

    2012-01-01

    Isolated tumor cells (ITC) are more common in the sentinel node (SN) after needle biopsy of a breast cancer, indicating iatrogenic displacement of tumor cells. We here investigate whether similar iatrogenic displacement occurs after surgical excision of a breast tumor. We compared the incidence...

  11. Radiation induced charge transfer inefficiencies in the Sentinel 4 instrument: modeling, performance, and correction

    Science.gov (United States)

    Irizar, J.; Gulde, S.; Skegg, M.; Levillain, Y.; Weber, H.

    2017-09-01

    Sentinel 4 is an imaging UVN (UV-VIS-NIR) dispersive spectrometer, developed by Airbus DS under an ESA contract in the frame of the joint EU/ESA COPERNICUS program. The instrument is introduced in a dedicated presentation in this conference.

  12. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer

    International Nuclear Information System (INIS)

    Vasques, Paulo Henrique Diogenes; Aquino, Ranniere Gurgel Furtado de; Pinheiro, Luiz Gonzaga Porto; Torres, Roberto Vitor Almeida; Bezerra, Jose Lucas Martins; Brasileiro, Luis Porto

    2015-01-01

    Purpose: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Methods: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. Results: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Conclusion: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy. (author)

  13. One-inch field of view imaging probe for breast cancer sentinel node location

    International Nuclear Information System (INIS)

    D'Errico, Giovanni; Scafe, Raffaele; Soluri, Alessandro; Schiaratura, Alfiero; Maria Mangano, Anna; David, Vincenzo; Scopinaro, Francesco

    2003-01-01

    The already reported 1-in. 2 field of view mini gamma camera known since 1998 with the name of Imaging Probe (IP), has been used for sentinel node localization by a medical equipe that, though trained by the group of nuclear physicians of the University 'La Sapienza' who first conceived and used this detector, has used IP in its own Hospital to: (1) gain experience for future use during operations--a cooperative work on IP radio guided orthopaedic operations has already started working, and (2) to start with IP multicenter trials. In six patients with breast cancer, who underwent lymphoscintigraphy for sentinel node biopsy, sentinel node was checked and located with IP and non-imaging Neoprobe 2000 CdTe (Zn) probe, independent of location by means of large field of view Anger camera. Operators who used Neoprobe and IP were blinded to each other and not aware of the results of Anger camera imaging. Anger camera, as well as IP and neoprobe detected 7 nodes in 6 pts. Detection time was 2', 06'' SD 26'' with IP and 2', 18'' SD 47'' with neoprobe 2000. The most difficult to find node required 2 min and 56 s--inside sd--for IP detection and 3 min and 45 s with neoprobe. Subjective impression of being sure of having detected sentinel node was: absolutely sure on 7/7 nodes with IP and on 5/7 nodes with neoprobe

  14. Songbirds as Sentinels of Mercury in Terrestrial Foodwebs of Eastern North America

    Science.gov (United States)

    Mercury is a globally distributed environmental contaminant with a variety of deleterious effects in fish, wildlife, and humans. Breeding songbirds may be useful sentinels for mercury because they are relatively easy to sample, have well-defined and small territories, and integra...

  15. Kennel dogs as sentinels of Leishmania infantum, Toxoplasma gondii and Neospora caninum in Majorca Island, Spain

    Science.gov (United States)

    Kennel dogs can serve as sentinels and/or reservoirs of diseases of veterinary and zoonotic interest because they have often roamed free and lived outdoors, being exposed to pathogens. We tested for evidence of infection with three protozoans, Leishmania infantum, Toxoplasma gondii and Neospora cani...

  16. Profile of illness in Syrian refugees: A GeoSentinel analysis, 2013 to 2015.

    Science.gov (United States)

    Mockenhaupt, Frank P; Barbre, Kira A; Jensenius, Mogens; Larsen, Carsten S; Barnett, Elizabeth D; Stauffer, William; Rothe, Camilla; Asgeirsson, Hilmir; Hamer, Davidson H; Esposito, Douglas H; Gautret, Philippe; Schlagenhauf, Patricia

    2016-01-01

    Screening of 488 Syrian unaccompanied minor refugees (Syrian refugees examined at GeoSentinel clinics worldwide, cutaneous leishmaniasis affected one in three patients; other noteworthy infections were active tuberculosis (11%) and chronic hepatitis B or C (9%). These data can contribute to evidence-based guidelines for infectious disease screening of Syrian refugees.

  17. SENTINEL-1/2 DATA FOR SHIP TRAFFIC MONITORING ON THE DANUBE RIVER

    Directory of Open Access Journals (Sweden)

    I. Dana Negula

    2016-06-01

    Full Text Available After a long period of drought, the water level of the Danube River has significantly dropped especially on the Romanian sector, in July-August 2015. Danube reached the lowest water level recorded in the last 12 years, causing the blockage of the ships in the sector located close to Zimnicea Harbour. The rising sand banks in the navigable channel congested the commercial traffic for a few days with more than 100 ships involved. The monitoring of the decreasing water level and the traffic jam was performed based on Sentinel-1 and Sentinel-2 free data provided by the European Space Agency and the European Commission within the Copernicus Programme. Specific processing methods (calibration, speckle filtering, geocoding, change detection, image classification, principal component analysis, etc. were applied in order to generate useful products that the responsible authorities could benefit from. The Sentinel data yielded good results for water mask extraction and ships detection. The analysis continued after the closure of the crisis situation when the water reached the nominal level again. The results indicate that Sentinel data can be successfully used for ship traffic monitoring, building the foundation of future endeavours for a durable monitoring of the Danube River.

  18. The evolution of the sentinel node procedure in the treatment of breast cancer.

    Science.gov (United States)

    Tvedskov, Tove Filtenborg

    2017-10-01

    This thesis is based on 10 original articles, of which 3 were previously included in the PhD thesis "Staging of women with breast cancer after introduction of sentinel node guided axillary dissection". In the PhD thesis is was shown that the introduction of sentinel lymph node dissection (SLND) in the treatment of breast cancer in Denmark has resulted in an increased identification of patients with micrometastases or isolated tumor cells (ITC) in the lymph nodes. Not all these small metastases are likely to disseminate to non-sentinel nodes. This thesis provides evidence that a previous surgical excision of a breast tumor is likely to lead to iatrogenic displacement of tumor cells resulting in a nearly four-fold increased risk of ITC in the sentinel node. These tumor cells are not associated with non-sentinel node metastases. Especially ITC, but also micrometastases and some macrometastases, are not identified on perioperative frozen sections, but found postoperatively at the conventional histopathological examination. These patients are offered an axillary lymph node dissection (ALND) as a second procedure. It has been suggested that this two-stage procedure reduces the number of lymph nodes removed, because of fibroses from previous surgery. In this thesis it was shown that a two-stage procedure does not result in a clinically relevant impairment of the number of lymph nodes removed by ALND. Based on patient, tumor, and sentinel node characteristics from the Danish Breast Cancer Group database, two predictive models for non-sentinel node metastases, when only micrometastases or ITC are found in the sentinel node, were developed, as a part of the PhD thesis. These two models have now been internally validated, and a cross-validation in a Finnish patient material has been performed in cooperation with researchers from Helsinki. The model for patients with micrometastases proved to be robust under internal as well as external validation and could be used to identify

  19. The GMES Sentinel-5 mission for operational atmospheric monitoring: status and developments

    Science.gov (United States)

    Sierk, Bernd; Bezy, Jean-Loup; Caron, Jerôme; Meynard, Roland; Veihelmann, Ben; Ingmann, Paul

    2017-11-01

    Sentinel-5 is an atmospheric monitoring mission planned in the frame of the joint EU/ESA initiative Global Monitoring for Environment and Security (GMES). The objective of the mission, planned to be launched in 2020, is the operational monitoring of trace gas concentrations for atmospheric chemistry and climate applications.

  20. Vanadium Mining and Cattle Health : Sentinel studies, epidemiological and veterinary public health issues

    NARCIS (Netherlands)

    Gummow, B.

    2005-01-01

    The thesis covers a field outbreak investigation into the cause and pathogenesis of "illthrift" on a dairy farm that was due to vanadium exposure, it examines methods of treating vanadium poisoning in cattle using an experimental study, looks at the use of cattle as sentinels for detecting and

  1. [Role of sentinel lymph nodes and lymphatic mapping of colorectal cancer].

    Science.gov (United States)

    Ivanov, K; Kolev, N; Ignatov, V; Temelkov, T; Madzhov, R

    2005-01-01

    The accuracy of staging of colorectal cancer is dependable of number of lymph nodes, colected and investegated from the pathologist. Moreover 50% of newfounded cases with colorectal cancer are diagnosed as I or II stage of the desease. Between 15% and 20% of these patients develop regional or distant metastases around 5 years after the examination, despite of the radical surgery. This may be due to pathological "understaging" (decrease of the stage), becouse of missed micrometastases, which size often is smaller than 5 mm. High accurate and specific pathologoanatomical methods for "ultrastaging" are cost-expensive, therefore their selective application to labeled sentinel lymph nodes has a economical benefit and saves a time. Moreover it is decreasing the understaging effect, assosiated with convectional pathologoanatomical investigaton. In the future, the technical progress will develop the intensive competiton between the sentinel lymph node mapping and the improved imaging diagnostic techniques as flurodeoxyglucose (18FDG), positron emision tomography (PET), or the other molecular imaging techniques. Unfortunately, the limited spatial resolution of these techniques, do not allow to be used for tumor staging as sentinel lymph node techniques. Therefore the sentinel lymphnode mapping become the choice of the lymphnode staging technique.

  2. Sentinel lymph nodes detection with an imaging system using Patent Blue V dye as fluorescent tracer

    Science.gov (United States)

    Tellier, F.; Steibel, J.; Chabrier, R.; Rodier, J. F.; Pourroy, G.; Poulet, P.

    2013-03-01

    Sentinel lymph node biopsy is the gold standard to detect metastatic invasion from primary breast cancer. This method can help patients avoid full axillary chain dissection, thereby decreasing the risk of morbidity. We propose an alternative to the traditional isotopic method, to detect and map the sentinel lymph nodes. Indeed, Patent Blue V is the most widely used dye in clinical routine for the visual detection of sentinel lymph nodes. A Recent study has shown the possibility of increasing the fluorescence quantum yield of Patent Blue V, when it is bound to human serum albumin. In this study we present a preclinical fluorescence imaging system to detect sentinel lymph nodes labeled with this fluorescent tracer. The setup is composed of a black and white CCD camera and two laser sources. One excitation source with a laser emitting at 635 nm and a second laser at 785 nm to illuminate the region of interest. The prototype is operated via a laptop. Preliminary experiments permitted to determine the device sensitivity in the μmol.L-1 range as regards the detection of PBV fluorescence signals. We also present a preclinical evaluation performed on Lewis rats, during which the fluorescence imaging setup detected the accumulation and fixation of the fluorescent dye on different nodes through the skin.

  3. Sentinel Lymph Node Biopsy and Isolated Tumor Cells in Invasive Lobular Versus Ductal Breast Cancer

    NARCIS (Netherlands)

    Truin, Wilfred; Roumen, Rudi M.; Siesling, Sabine; van der Heiden-van der Loo, Margriet; Lobbezoo, Dorien J.; Tjan-Heijnen, Vivianne C.G.; Voogd, Adri C.

    2016-01-01

    Background Sentinel lymph node (SLN) biopsy is the standard of care for axillary staging in invasive breast cancer. The introduction of SLN biopsy with an extensive pathology examination, in addition to the introduction of the 2002 TNM classification, led to different axillary classification

  4. Does sentinel lymph node biopsy have a role in node- positive head ...

    African Journals Online (AJOL)

    10.1097/MOO.0b013e3283293631]. 6. Taylor RJ, Wahl RL, Sharma PK, et al. Sentinel node localization in oral cavity and oropharynx squamous cell cancer. Arch Otolaryngol Head Neck Surg. 2001;127(8):970-974. 7. Nieuwenhuis EJ, Pijpers R, ...

  5. Improved sentinel node visualization in breast cancer by optimizing the colloid particle concentration and tracer dosage

    NARCIS (Netherlands)

    Valdés Olmos, R. A.; Tanis, P. J.; Hoefnagel, C. A.; Nieweg, O. E.; Muller, S. H.; Rutgers, E. J.; Kooi, M. L.; Kroon, B. B.

    2001-01-01

    Faint lymph uptake may hamper sentinel node (SN) identification by scintigraphy and subsequent gamma probe localization. The aim of the present study was to evaluate an adjustment in the colloid particle concentration and tracer dosage to optimize mammary lymphoscintigraphy. Scintigraphy was

  6. The potential of Sentinel-2 spectral configuration to assess rangeland quality

    CSIR Research Space (South Africa)

    Ramoelo, Abel

    2015-08-01

    Full Text Available was measured using the analytical spectral device (ASD) in concert with leaf sample collections for leaf N chemical analysis. ASD reflectance data were resampled to the spectral bands of Sentinel-2 using published spectral response functions. Random forest (RF...

  7. Sentinel node biopsy and concomitant probe-guided tumor excision of nonpalpable breast cancer

    NARCIS (Netherlands)

    van Rijk, Maartje C.; Tanis, Pieter J.; Nieweg, Omgo E.; Loo, Claudette E.; Valdés Olmos, Renato A.; Oldenburg, Hester S. A.; Rutgers, Emiel J. Th; Hoefnagel, Cornelis A.; Kroon, Bin B. R.

    2007-01-01

    BACKGROUND: Preliminary data have shown encouraging results of a single intratumoral radiopharmaceutical injection that enables both sentinel node biopsy and probe-guided excision of the primary tumor in patients with nonpalpable breast cancer. The aim of the study was to evaluate this approach in a

  8. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vasques, Paulo Henrique Diogenes; Aquino, Ranniere Gurgel Furtado de; Pinheiro, Luiz Gonzaga Porto, E-mail: luizgporto@uol.com.br [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Departamento de Cirurgia; Alves, Mayara Maia [Rede Nordeste de Biotecnologia (RENORBIO/UFC), Fortaleza, CE (Brazil); Torres, Roberto Vitor Almeida; Bezerra, Jose Lucas Martins [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Faculdade de Medicina; Brasileiro, Luis Porto [Faculdades INTA, Sobral, CE (Brazil). Faculdade de Medicina

    2015-11-15

    Purpose: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Methods: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. Results: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Conclusion: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy. (author)

  9. Cytokeratin on frozen sections of sentinel node may spare breast cancer patients secondary axillary surgery

    DEFF Research Database (Denmark)

    Stovgaard, Elisabeth Specht; Tvedskov, Tove Filtenborg; Lænkholm, Anne Vibeke

    2012-01-01

    Background. The feasibility and accuracy of immunohistochemistry (IHC) on frozen sections, when assessing sentinel node (SN) status intraoperatively in breast cancer, is a matter of continuing discussion. In this study, we compared a center using IHC on frozen section with a center not using this...

  10. The role of sentinel node biopsy in gynecological cancer : a review

    NARCIS (Netherlands)

    Oonk, Maaike H. M.; van de Nieuwenhof, Hedwig P.; de Hullu, Joanne A.; van der Zee, Ate G. J.

    Purpose of review In early-stage vulvar, cervical and endometrial cancer, lymph node status is the most important prognostic factor. Surgical treatment is aimed at removing the primary tumor and adequately staging the regional lymph nodes. As morbidity of regional lymphadenectomy is high, sentinel

  11. National equipment of intraoperatory gamma detection in the identification of sentinel lymph node in animal model

    International Nuclear Information System (INIS)

    Santos, Paula Cristina Fada dos; Santos, Ivan Dunshee de Abranches Oliveira; Nahas, Fabio Xerfan; Ferreira, Lydia Masako; Oliveira Filho, Renato Santos de

    2009-01-01

    Purpose: To investigate a national equipment of intraoperatory gamma detection in the identification of sentinel lymph node. Methods: Thirty young adult male rats were used. After anesthetized, animals were divided into two groups of 15 animals each. Animals from group A received dextram 500 - Tc 99 radiopharmaceutical and patent blue V and those from group B received only patent blue V to map the lymphatic drainage. The presence of radiation in the background area, in the area of injection and of the ex vivo sentinel lymph node of group A were measured. After the exeresis, each lymph node in group A and in group B was mixed forming a new random sequence and the radioactive reading of each lymph node was carried out, using both pieces of equipment. Results: The hottest sentinel lymph node was identified by the national equipment when radiation was measured in the area of lymphatic drainage after the Dextran 500 was injected. Also, the ex vivo sentinel lymph node. The national equipment has also detected radiation in the lymph nodes that had not received radiopharmaceutical, leading to false positive, checked by the application of Mann-Whitney tests and Student's paired t-tests. The Cronbach alpha has shown high internal consistency of data 0,9416. Conclusions: The national equipment of intraoperatory gamma detection identifies the LS and showed false positives LS and needs improvement. (author)

  12. Effects of previous surgery on the detection of sentinel nodes in women with vulvar cancer.

    NARCIS (Netherlands)

    Ennik, T.A.; Allen, D.G; Bekkers, R.L.M.; Hyde, S.E.; Grant, P.T.

    2011-01-01

    BACKGROUND: There is a growing interest to apply the sentinel node (SN) procedure in the treatment of vulvar cancer. Previous vulvar surgery might disrupt lymphatic patterns and thereby decrease SN detection rates, lengthen scintigraphic appearance time (SAT), and increase SN false-negative rate.

  13. Anatomy and physiology of lymphatic drainage of the breast from the perspective of sentinel node biopsy

    NARCIS (Netherlands)

    Tanis, P. J.; Nieweg, O. E.; Valdés Olmos, R. A.; Kroon, B. B.

    2001-01-01

    Knowledge of the anatomy and physiology of the lymphatic system is helpful when considering a particular sentinel node biopsy technique. The delicate balance between internal and external pressures in a lymphatic channel can be influenced by the injection volume and by massage in a negative or

  14. Experimental Sentinel-2 LAI estimation using parametric, non-parametric and physical retrieval methods - A comparison

    NARCIS (Netherlands)

    Verrelst, Jochem; Rivera, Juan Pablo; Veroustraete, Frank; Muñoz-Marí, Jordi; Clevers, J.G.P.W.; Camps-Valls, Gustau; Moreno, José

    2015-01-01

    Given the forthcoming availability of Sentinel-2 (S2) images, this paper provides a systematic comparison of retrieval accuracy and processing speed of a multitude of parametric, non-parametric and physically-based retrieval methods using simulated S2 data. An experimental field dataset (SPARC),

  15. Tc-99m Diphosphonate as a Potential Radiotracer to Detect Sentinel Lymph Nodes in Patients with Breast Cancer

    International Nuclear Information System (INIS)

    Yang, You Jung; Lim, Sung Jig; Song, Jeong Yoon

    2010-01-01

    To evaluate the potential of Tc-99m diphosphonate as a tracer for sentinel lymph node biopsy in breast cancer. Lymphoscintigraphy of 35 patients (50.9±10.2 years) with breast cancer were acquired after administering a subauroral intradermal injection of Tc-99m diphosphonate 18 h before surgery. Static images were taken within 15 min (early phase) and 15 h after injection (delayed phase). The lymphoscintigraphy identification rate was defined as the percentage of subjects studied with visible foci at axillae. Sentinel lymph node biopsies were performed using a gamma probe and by blue dye injection. Any node that was radioactive or stained with blue dye was labeled as a sentinel lymph node. Lymph nodes without radioactivity or blue dye staining were defined as non sentinel lymph nodes. The intraoperative identification rate was defined as the percentage of patients with a radioactive sentinel lymph node. Percentages of lymphoid cells expressing S-100, CD83, and CD1a were compared. The lymphoscintigraphy identification rate was 94.3% (33/35) during the early phase and 96.9% (31/32) during the delayed phase, whereas the intraoperative identification rate was 94.3% (33/35). The mean percentages of lymphoid cells that stained positively for S-100 or CD83 were lower in sentinel lymph nodes than in non sentinel lymph nodes (1.5% vs. 9.0% for S-100, and 4.5% vs. 9.3% for CD83, respectively, p=0.0286). The mean percentages of lymphoid cells in sentinel lymph nodes and non-sentinel lymph nodes expressing CD1a were 3.3% and 7.0%, respectively (p=ns). Conclusions Tc-99m diphosphonate can reliably detect regional lymph nodes in breast cancer.

  16. Sentinel lymph node mapping in minimally invasive surgery: Role of imaging with color-segmented fluorescence (CSF).

    Science.gov (United States)

    Lopez Labrousse, Maite I; Frumovitz, Michael; Guadalupe Patrono, M; Ramirez, Pedro T

    2017-09-01

    Sentinel lymph node mapping, alone or in combination with pelvic lymphadenectomy, is considered a standard approach in staging of patients with cervical or endometrial cancer [1-3]. The goal of this video is to demonstrate the use of indocyanine green (ICG) and color-segmented fluorescence when performing lymphatic mapping in patients with gynecologic malignancies. Injection of ICG is performed in two cervical sites using 1mL (0.5mL superficial and deep, respectively) at the 3 and 9 o'clock position. Sentinel lymph nodes are identified intraoperatively using the Pinpoint near-infrared imaging system (Novadaq, Ontario, CA). Color-segmented fluorescence is used to image different levels of ICG uptake demonstrating higher levels of perfusion. A color key on the side of the monitor shows the colors that coordinate with different levels of ICG uptake. Color-segmented fluorescence may help surgeons identify true sentinel nodes from fatty tissue that, although absorbing fluorescent dye, does not contain true nodal tissue. It is not intended to differentiate the primary sentinel node from secondary sentinel nodes. The key ranges from low levels of ICG uptake (gray) to the highest rate of ICG uptake (red). Bilateral sentinel lymph nodes are identified along the external iliac vessels using both standard and color-segmented fluorescence. No evidence of disease was noted after ultra-staging was performed in each of the sentinel nodes. Use of ICG in sentinel lymph node mapping allows for high bilateral detection rates. Color-segmented fluorescence may increase accuracy of sentinel lymph node identification over standard fluorescent imaging. The following are the supplementary data related to this article. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. The future of nursing: how important is discipline-specific knowledge? A conversation with Jacqueline Fawcett. Interview by Dr. Janie Butts and Dr. Karen Rich.

    Science.gov (United States)

    Fawcett, Jacqueline

    2012-04-01

    Nurses have long attempted to secure a unique identity for the profession. Many scholars are now promoting an interdisciplinary framework for nursing practice. Fawcett is convinced that interdisciplinary practice poses a danger for nursing to lose its identity and that interdisciplinary practice cannot be successful if members of each discipline do not understand the conceptual models, practice, and research of their own discipline. Dr. Janie Butts and Dr. Karen Rich interviewed Dr. Jacqueline Fawcett about her views related to discipline-specific knowledge and nursing's future. The authors conclude that Fawcett's scientific foundation gives nursing the solidarity and power necessary to determine the unique internal goods of its practice.

  18. Sentinel-1A - Launching the first satellite and launching the operational Copernicus programme

    Science.gov (United States)

    Aschbacher, Josef; Milagro Perez, Maria Pilar

    2014-05-01

    The first Copernicus satellite, Sentinel-1A, is prepared for launch in April 2014. It will provide continuous, systematic and highly reliable radar images of the Earth. Sentinel-1B will follow around 18 months later to increase observation frequency and establish an operational system. Sentinel-1 is designed to work in a pre-programmed conflict-free operation mode ensuring the reliability required by operational services and creating a consistent long-term data archive for applications based on long time series. This mission will ensure the continuation and improvement of SAR operational services and applications addressing primarily medium- to high-resolution applications through a main mode of operation that features both a wide swath (250 km) and high geometric (5 × 20 m) and radiometric resolution, allowing imaging of global landmasses, coastal zones, sea ice, polar areas, and shipping routes at high resolution. The Sentinel-1 main operational mode (Interferometric Wide Swath) will allow to have a complete coverage of the Earth in 6 days in the operational configuration when the two Sentinel-1 spacecraft will be in orbit simultaneously. High priority areas like Europe, Canada and some shipping routes will be covered almost daily. This high global observation frequency is unprecedented and cannot be reached with any other current radar mission. Envisat, for example, which was the 'workhorse' in this domain up to April 2012, reached global coverage every 35 days. Sentinel-1 data products will be made available systematically and free of charge to all users including institutional users, the general public, scientific and commercial users. The transition of the Copernicus programme from the development to operational phase will take place at about the same time when the first Sentinel-1 satellite will be launched. During the operational phase, funding of the programme will come from the European Union Multiannual Financial Framework (MFF) for the years 2014

  19. Sentinel lymph node in breast cancer using a radiocolloid particle produced in Argentina

    International Nuclear Information System (INIS)

    Velazquez Espeche, M.H.; Soroa, V.E.; Castiglia, S.G. de

    2004-01-01

    Full text: A number of different approaches have been adopted in the application of technique to detect sentinel lymph node. The main variables are related to size of colloid used, the time to surgery following administration of the colloid, the volume of injection and the site of administration. Optimal detections of sentinel lymph node requires the use of radiopharmaceuticals which clear rapidly from the site of injection and which will be wholly retained at the level of first tier nodes. Our objective was to apply a radiocolloid particle of size between 100-220 nm produced in Argentina by CNEA and to determine its efficacy in sentinel node detections in breast cancer. The particle size was determinate by successive filtrations of a single sample through 450, 220, 100 and 20 nm pore size filters (Whatmaan, UK). The product stability was determined by chromatography controls with ITLC, The pattern of biodistribution in animal was studied in Wistar rats. Twenty female patients with breast cancer diagnosed by clinical, mammography and cytology, were investigated. Four injections of 7.4-22 MBq of 99mTc human albumin radio colloid in volume of 0.5 ml, were injected along the subcutaneous peripheral tumor margins when the tumor was palpable. Peri-subareolar subcutaneous injection in volume of 0.1 ml was also employed as an alternative in few cases. After the injection the patient massaged the injection site for about five minutes. Lymphoscintigrams were acquired in dynamic, static and transmission modes. The sentinel node was marked with a demographic pencil with the patient lying supine and with the arm on the affected side abducted at approximately 90 0 to ensure the same anatomical localization as during the surgery. During the surgery a gamma probe localized the sentinel node by count and sound. Based on the size of particles, the distribution was 90% between 100-220 nm, 7.3% between 200 and 450 nm and 2.7% less than 100 nm. The radiolabel purity was greater than

  20. A 1 cm space debris impact onto the Sentinel-1A solar array

    Science.gov (United States)

    Krag, H.; Serrano, M.; Braun, V.; Kuchynka, P.; Catania, M.; Siminski, J.; Schimmerohn, M.; Marc, X.; Kuijper, D.; Shurmer, I.; O'Connell, A.; Otten, M.; Muñoz, Isidro; Morales, J.; Wermuth, M.; McKissock, D.

    2017-08-01

    Sentinel-1A is a 2-ton spacecraft of the Copernicus Earth observation program operated by ESA's Space Operations Centre in Darmstadt, Germany. Sentinel-1A and its sister spacecraft Sentinel-1B operate in a sun-synchronous orbit at about 700 km altitude. On 2016/08/23 17:07:37 UTC, Sentinel-1A suffered from an anomaly resulting in a sudden permanent partial power loss and significant impulsive orbit and attitude changes. A deeper investigation identified that an impulsive orbit change against flight direction of 0.7 mm/s, estimated at the time of the event, gave the best results in terms of GPS residuals. At the same time, a peak attitude off-pointing of 0.7° (around the spacecraft yaw axis) and peak attitude rate increase of 0.04°/s (around the same axis) were observed. The simultaneous occurrence of these anomalies, starting from a sudden attitude change and ending with a permanent partial power loss, made an MMOD (Micro-Meteoroid and Orbital Debris) impact onto a solar array a possible explanation for this event. While the spacecraft is able to continue its mission nominally, a detailed investigation involving ESA's Space Debris and Flight Dynamics experts was conducted. An MMOD impact as an explanation gained further credibility, due to the pictures of the solar array taken by the on-board camera displaying a significant damage area. On September 7th, JSpOC (US Joint Space Operations Centre) informed SDO on 8 tracked fragments that are considered to be released by Sentinel-1A after the impact. This paper addresses the analysis that was performed on the data characterising the attitude and orbit change, the on-board camera image, and the tracked fragments. The data helped to identify the linear momentum vector while a flux analysis helped to identify the origin of the impactor and allowed to understand its mass and size characteristics.