WorldWideScience

Sample records for upper laser level

  1. Kinetics of excited levels in copper-vapor laser

    International Nuclear Information System (INIS)

    Smilanski, I.

    1981-10-01

    A full and representative description of the excited copper level kinetics in a copper-vapor laser is presented. The research was carried out in three stages. The first stage was the development of a representative and reliable measurement cell. A laser tube constructed of refractory materials and an excitation circuit which provides short pulses at a high repetition rate to heat the tube and excite the copper atoms were developed. This stage was also dedicated to characterizing the laser and studying its scaling laws. In the second stage a rapid neasuring system which avoids the problem of spectral line shape was developed. The system is based on the 'hook' method, which utilizes the anomalous dispersion in the vicinity of an atomic line. The light source, a wide band nitrogen-laser-pumped dye laser, ensures a short sampling time, and the recording system, with a television camera face as the recording medium, allows precise data reduction. In the third stage the excited copper level kinetics in a copper vapor laser is measured. The principal conclusions, that only a small part of the energy in the discharge is utilized to populate the upper laser levels and that the lower laser level population is very large at the end of the excitation pulse and cannot be attributed to relaxation of the upper levels, necessitate a new kinetic description of the copper-vapor laser. The laser is not self-terminating; it is activated and terminated by the electrical discharge

  2. Upper Eyelid Fractional CO2 Laser Resurfacing With Incisional Blepharoplasty.

    Science.gov (United States)

    Kotlus, Brett S; Schwarcz, Robert M; Nakra, Tanuj

    2016-01-01

    Laser resurfacing, performed at the same time as blepharoplasty, has most commonly been applied to the lower eyelid skin but can effectively be used on the upper eyelid to reduce rhytidosis and improve skin quality. The authors evaluate the safety and efficacy of this procedure. Fractional CO2 laser resurfacing was performed in conjunction with incisional upper blepharoplasty. The ultrapulsed laser energy was applied to the sub-brow skin, the upper medial canthal skin, and the pretarsal skin in 30 patients. Photos were obtained preoperatively and at 3 months. All patients demonstrated reduction in upper eyelid rhytidosis without any serious complications. Independent rhytidosis grading (0-4) showed a mean improvement of 42%. One patient experienced wound dehiscence that satisfactorily resolved without intervention. Upper eyelid laser resurfacing is effective and can be safely performed at the same time as upper blepharoplasty. This approach reduces or eliminates the need for medial incisions to address medial canthal skin redundancy and rhytidosis and it directly treats upper eyelid wrinkles on residual eyelid and infra-brow skin during blepharoplasty.

  3. Optimization of end-pumped, actively Q-switched quasi-III-level lasers.

    Science.gov (United States)

    Jabczynski, Jan K; Gorajek, Lukasz; Kwiatkowski, Jacek; Kaskow, Mateusz; Zendzian, Waldemar

    2011-08-15

    The new model of end-pumped quasi-III-level laser considering transient pumping processes, ground-state-depletion and up-conversion effects was developed. The model consists of two parts: pumping stage and Q-switched part, which can be separated in a case of active Q-switching regime. For pumping stage the semi-analytical model was developed, enabling the calculations for final occupation of upper laser level for given pump power and duration, spatial profile of pump beam, length and dopant level of gain medium. For quasi-stationary inversion, the optimization procedure of Q-switching regime based on Lagrange multiplier technique was developed. The new approach for optimization of CW regime of quasi-three-level lasers was developed to optimize the Q-switched lasers operating with high repetition rates. Both methods of optimizations enable calculation of optimal absorbance of gain medium and output losses for given pump rate. © 2011 Optical Society of America

  4. Discovery of new Praseodymium I energy levels with help of green laser light

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Shamim; Siddiqui, Imran; Tanweer Iqbal, Syed; Windholz, Laurentius [Institute of Experimental Physics, Graz University of Technology, Petersgasse 16, A 8010 Graz (Austria)

    2012-07-01

    The hyperfine structure (hfs) of Praseodymium I spectral lines were experimentally investigated using LIF technique in a hollow cathode discharge lamp. We report here the investigation of 100 spectral lines which resulted in a discovery of 20 new energy levels of even and odd parity. The excitation source is a tunable ring-dye laser system, operated with Coumarin 102. The laser wavelength is tuned to a strong hyperfine component of the investigated spectral line, and fluorescence signals from excited levels are searched. The hfs of the investigated line is recorded by scanning the laser frequency across the investigated region. Magnetic hf interaction constant ''A'' and angular momentum ''J'' of the combining lower and upper levels involved in the formation of the line are evaluated. If one of the combining levels is not known (in most cases upper level), the determined angular momentum ''J'' and hyperfine constant ''A'' are used to identify one of the involved levels (in most cases the lower level) and the energy of the unknown level is determined by using center of mass wave number of line and the energy of the identified level. The level found in this way must explain most of the observed fluorescence wavelengths and the hyperfine structure of the fluorescence lines appearing in FT spectrum.

  5. Study of parameters of simultaneous lasing on two lines sharing an upper level

    International Nuclear Information System (INIS)

    Pikulev, A A

    2002-01-01

    Stationary lasing at two competing lines sharing an upper level is studied. Based on the expressions for the gain obtained earlier, the possible lasing regimes are considered (at one or two lines) and approximate formulas are derived for determining the output power in each line. These formulas are shown to be the generalisation of the Rigrod formula to the case of simultaneous lasing at several lines. (control of laser radiation parameters)

  6. Upper Limit for Regional Sea Level Projections

    Science.gov (United States)

    Jevrejeva, Svetlana; Jackson, Luke; Riva, Riccardo; Grinsted, Aslak; Moore, John

    2016-04-01

    With more than 150 million people living within 1 m of high tide future sea level rise is one of the most damaging aspects of warming climate. The latest Intergovernmental Panel on Climate Change report (AR5 IPCC) noted that a 0.5 m rise in mean sea level will result in a dramatic increase the frequency of high water extremes - by an order of magnitude, or more in some regions. Thus the flood threat to the rapidly growing urban populations and associated infrastructure in coastal areas are major concerns for society. Hence, impact assessment, risk management, adaptation strategy and long-term decision making in coastal areas depend on projections of mean sea level and crucially its low probability, high impact, upper range. With probabilistic approach we produce regional sea level projections taking into account large uncertainties associated with Greenland and Antarctica ice sheets contribution. We calculate the upper limit (as 95%) for regional sea level projections by 2100 with RCP8.5 scenario, suggesting that for the most coastlines upper limit will exceed the global upper limit of 1.8 m.

  7. Upper-Level Waves of Synoptic Scale at Midlatitudes

    Science.gov (United States)

    Rivest, Chantal

    1990-01-01

    Upper-level waves of synoptic scale are important dynamical entities at midlatitudes. They often induce surface cyclogenesis (cf. Peterssen and Smebye, 1971), and their life duration is typically longer than time scales for disruption by the ambient shear (Sanders, 1988). The objectives of the present thesis are to explain the maintenance and genesis of upper-level synoptic-scale waves in the midlatitude flow. We develop an analytical model of waves on generalized Eady basic states that have uniform tropospheric and stratospheric potential vorticity, but allow for the decay of density with height. The Eady basic state represents the limiting case of infinite stratospheric stability and constant density. We find that the Eady normal mode characteristics hold in the presence of realistic tropopause and stratosphere. In particular, the basic states studied support at the synoptic scale upper-level normal modes. These modes provide simple models for the dynamics of upper-level synoptic-scale waves, as waves supported by the large latitudinal gradients of potential vorticity at the tropopause. In the presence of infinitesimal positive tropospheric gradients of potential vorticity, the upper-level normal mode solutions no longer exist, as was demonstrated in Green (1960). Disappearance of the normal mode solution when a parameter changes slightly represents a dilemma that we seek to understand. We examine what happens to the upper-level normal modes in the presence of tropospheric gradients of potential vorticity in a series of initial -value experiments. Our results show that the normal modes become slowly decaying quasi-modes. Mathematically the quasi-modes consist of a superposition of singular modes sharply peaked in the phase speed domain, and their decay proceeds as the modes interfere with one another. We repeat these experiments in basic states with a smooth tropopause in the presence of tropospheric and stratospheric gradients, and similar results are obtained

  8. Testing of Selective Laser Melting Turbomachinery Applicable to Exploration Upper Stage

    Science.gov (United States)

    Calvert, Marty; Turpin, Jason; Nettles, Mindy

    2015-01-01

    This task is to design, fabricate, and spin test to failure a Ti6-4 hydrogen turbopump impeller that was built using the selective laser melting (SLM) fabrication process (fig. 1). The impeller is sized around upper stage engine requirements. In addition to the spin burst test, material testing will be performed on coupons that are built with the impeller.

  9. Assessing Upper-Level Winds on Day-of-Launch

    Science.gov (United States)

    Bauman, William H., III; Wheeler, Mark M.

    2012-01-01

    On the day-or-launch. the 45th Weather Squadron Launch Weather Officers (LWOS) monitor the upper-level winds for their launch customers to include NASA's Launch Services Program (LSP). During launch operations, the payload launch team sometimes asks the LWO if they expect the upper level winds to change during the countdown but the LWOs did not have the capability to quickly retrieve or display the upper-level observations and compare them to the numerical weather prediction model point forecasts. The LWOs requested the Applied Meteorology Unit (AMU) develop a capability in the form of a graphical user interface (GUI) that would allow them to plot upper-level wind speed and direction observations from the Kennedy Space Center Doppler Radar Wind Profilers and Cape Canaveral Air Force Station rawinsondes and then overlay model point forecast profiles on the observation profiles to assess the performance of these models and graphically display them to the launch team. The AMU developed an Excel-based capability for the LWOs to assess the model forecast upper-level winds and compare them to observations. They did so by creating a GUI in Excel that allows the LWOs to first initialize the models by comparing the O-hour model forecasts to the observations and then to display model forecasts in 3-hour intervals from the current time through 12 hours.

  10. Laser light scattering basic principles and practice

    CERN Document Server

    Chu, Benjamin

    1994-01-01

    Geared toward upper-level undergraduate and graduate students, this text introduces the interdisciplinary area of laser light scattering, focusing chiefly on theoretical concepts of quasielastic laser scattering.

  11. Comparison of Pneumatic and Laser Lithotripsy in the Endoscopic Treatment of Upper Ureteral Stones

    Directory of Open Access Journals (Sweden)

    Ozer Guzel

    2016-04-01

    Full Text Available Aim: We aimed to compare the success rate of the use of a pneumatic and a holmium laser lithotripter for endoscopic treatment of upper ureteral calculi with semirigid uretero-renoscopy (URS. Material and Method: A total of 74 patients were included in this study. The patients were divided into two groups; a ballistic lithotripter was used for group 1 containing 33 and a Holmium-YAG laser lithotripter for the remaining 41 patients in group 2. Both groups were compared in terms of stone size the duration of the operation, postoperative hospitalization time, stone-free rate and complications. Results: The mean age of the patients was 47.6. The mean stone size in groups 1 and 2 were 16.4mm and 11.0mm, respectively (p=0.043. The mean stone-free rate groups 1 and 2 were 78.7% and 80.5% respectively at the approximately 1 month follow-up (p=0.391. In group 1 two patients and in group 2 two patients had a minor complication (ClavienI-II. In group 1 three patients had major complications due to ureteral perforation (Clavien 3a and 3b. No major complications (Clavien III-V occurred in Group 2. Discussion: Based on these findings laser lithotripsy can be regarded as safer. If laser lithotripter is available in medical centers, we argue that it should be the first choice for the treatment of upper ureteral stones.

  12. Performance evaluation of laser guided leveler

    Directory of Open Access Journals (Sweden)

    M.A. Hoque

    2014-12-01

    Full Text Available The study was conducted at Bangladesh Agricultural Research Institute (BARI farm on clay loam soil during Rabi season of 2010-2011. The treatments consisted of laser land leveling (T1 and control (non-leveled (T2. A preliminary field survey was done using staff gage. Initially a base station was established to dispense laser ray uniformly. The laser ray erected from base station guided the sensor of the stuff gage and the leveler. Elevation data was collected from the different points of the field and made an average. The maximum gage reading were 247.0 cm and the minimum gage reading was 219.2 cm. Average gage readings of the laser leveled plot was 235.66 cm that was settled for auto adjustment. Therefore, huge amount of soils (16.46 cm high was cut from the highest point and subsequently had to fill to the low points. Finally, an equal gage reading of 235.66 cm was observed after leveling the plot. The laser leveler (Leica MLS700 was used hitching with a TAFE tractor. The field was leveled with manual control initially and finally it was operated with auto adjustment. Two operators, 25 litter diesels and total 6 hours time were required during this leveling. Wheat was cultivated in leveled land (T1 and non-leveled land (T2. Laser leveling was insured for improvement in nutrient use efficiencies, option for precision farming, reduces weed problems, and improves uniformity of crop maturity. There was better distribution of water in leveled plot, which helped to reduce irrigation application time 1 hour. Due to uniformity of moisture content improved germination and crop establishment was found which reflected in higher plant population (239 m-2. Maximum yield (3.41 t ha-1 was obtained in T1 due to longer panicle (10.89 cm, more grain per plant (27.47 and 1000 grain weight (47.38 g compared to yield of T2 (2.62 t ha-1.

  13. Effect of Low-Level Laser Stimulation on EEG

    Directory of Open Access Journals (Sweden)

    Jih-Huah Wu

    2012-01-01

    Full Text Available Conventional laser stimulation at the acupoint can induce significant brain activation, and the activation is theoretically conveyed by the sensory afferents. Whether the insensible low-level Laser stimulation outside the acupoint could also evoke electroencephalographic (EEG changes is not known. We designed a low-level laser array stimulator (6 pcs laser diode, wavelength 830 nm, output power 7 mW, and operation frequency 10 Hz to deliver insensible laser stimulations to the palm. EEG activities before, during, and after the laser stimulation were collected. The amplitude powers of each EEG frequency band were analyzed. We found that the low-level laser stimulation was able to increase the power of alpha rhythms and theta waves, mainly in the posterior head regions. These effects lasted at least 15 minutes after cessation of the laser stimulation. The amplitude power of beta activities in the anterior head regions decreased after laser stimulation. We thought these EEG changes comparable to those in meditation.

  14. Effect of low-level laser stimulation on EEG.

    Science.gov (United States)

    Wu, Jih-Huah; Chang, Wen-Dien; Hsieh, Chang-Wei; Jiang, Joe-Air; Fang, Wei; Shan, Yi-Chia; Chang, Yang-Chyuan

    2012-01-01

    Conventional laser stimulation at the acupoint can induce significant brain activation, and the activation is theoretically conveyed by the sensory afferents. Whether the insensible low-level Laser stimulation outside the acupoint could also evoke electroencephalographic (EEG) changes is not known. We designed a low-level laser array stimulator (6 pcs laser diode, wavelength 830 nm, output power 7 mW, and operation frequency 10 Hz) to deliver insensible laser stimulations to the palm. EEG activities before, during, and after the laser stimulation were collected. The amplitude powers of each EEG frequency band were analyzed. We found that the low-level laser stimulation was able to increase the power of alpha rhythms and theta waves, mainly in the posterior head regions. These effects lasted at least 15 minutes after cessation of the laser stimulation. The amplitude power of beta activities in the anterior head regions decreased after laser stimulation. We thought these EEG changes comparable to those in meditation.

  15. Balanced cross-rate model for saturated molecular fluorescence in flames using a nanosecond pulse length laser

    International Nuclear Information System (INIS)

    Lucht, R.P.; Sweeney, D.W.; Laurendeau, N.M.

    1980-01-01

    The balanced cross-rate model is proposed to analyze laser-induced molecular fluorescence signals when the laser pulse length is of the order of nanoseconds. Nanosecond pulse length lasers. specifically Q-switched Nd:YAG-pumped dye lasers, are attractive for saturated molecular fluorescence spectroscopy because of their high peak power and because of their short pulse length minimizes the risk of laser-induced chemistry. In the balanced cross-rate model, single upper and lower rotational levels are assumed to be directly coupled by the laser radiation. Because the laser-induced processes which couple these levels are so fast at saturation intensities, a steady state is established between the two levels within picoseconds. Provided that the total population of the two laser-coupled rotational levels is constant during the laser pulse, the total molecular population can be calculated from the observed upper rotational level population using a two-level saturation model and Boltzmann statistics. Numerical simulation of the laser excitation dynamics of OH in an atmospheric pressure H 2 /O 2 /N 2 flame indicates that the balanced cross-rate model will give accurate results provided that the rotational relaxation rates in the upper and lower sets of rotational levels are approximately equal

  16. Experience of curing serious obstruction of advanced-stage upper digestive tract tumor using laser under endoscope

    Science.gov (United States)

    Mu, Hai-Bin; Zhang, Man-Ling; Zhang, Xiao-Qiang; Zhang, Feng-Qiu; Kong, De-Jia; Tang, Li-Bin

    1998-11-01

    The patients who suffer from upper digestive tract tumor, such as cancer of esophagus, cancer of cardia, all have serious obstruction and fail to get nutrition and can not bear the strike of the radiotherapy and chemotherapy. In order to reduce the obstruction symptom and suffering of the patients and to prolong their life time, since 1989, our hospital used the laser to cure the upper digestive tract tumor 11 cases with serious obstruction and got remarkable curative effect.

  17. Enhancement of optical Kerr effect in quantum-cascade lasers with multiple resonance levels.

    Science.gov (United States)

    Bai, Jing; Citrin, D S

    2008-08-18

    In this paper, we investigated the optical Kerr lensing effect in quantum-cascade lasers with multiple resonance levels. The Kerr refractive index n2 is obtained through the third-order susceptibility at the fundamental frequency chi(3)( omega; omega, omega,-omega). Resonant two-photon processes are found to have almost equal contributions to chi(3)( omega; omega, omega,-omega) as the single-photon processes, which result in the predicted enhancement of the positive nonlinear (Kerr) refractive index, and thus may enhance mode-locking of quantum-cascade lasers. Moreover, we also demonstrate an isospectral optimization strategy for further improving n2 through the band-structure design, in order to boost the multimode performance of quantum-cascade lasers. Simulation results show that the optimized stepwise multiple-quantum-well structure has n2 approximately 10-8 cm2/W, a twofold enhancement over the original flat quantum-well structure. This leads to a refractive-index change (delta)n of about 0.01, which is at the upper bound of those reported for typical Kerr medium. This stronger Kerr refractive index may be important for quantum-cascade lasers ultimately to demonstrate self-mode-locking.

  18. Quasi-three level Nd:YLF fundamental and Raman laser operating under 872-nm and 880-nm direct diode pumping

    Science.gov (United States)

    Wetter, Niklaus U.; Bereczki, Allan; Paes, João. Pedro Fonseca

    2018-02-01

    Nd:YLiF4 is the gain material of choice whenever outstanding beam quality or a birefringent gain material is necessary such as in certain applications for terahertz radiation or dual-frequency mode-locking. However, for high power CW applications the material is hampered by a low thermal fracture threshold. This problem can be mitigated by special 2D pump set-ups or by keeping the quantum defect to a minimum. Direct pumping into the upper laser level of Nd:YLiF4 is usually performed at 880 nm. For quasi-three level laser emission at 908 nm, direct pumping at this wavelength provides a high quantum defect of 0.97, which allows for very high CW pump powers. Although the direct pumping transition to the upper laser state at 872 nm has a slightly smaller quantum defect of 0.96, its pump absorption cross section along the c-axis is 50% higher than at 880 nm, leading to a higher absorption efficiency. In this work we explore, for the first time to our knowledge, 908 nm lasing under 872 nm diode pumping and compare the results with 880 nm pumping for quasicw and cw operation. By inserting a KGW crystal in the cavity, Raman lines at 990 nm and 972 nm were obtained for the first time from a directly pumped 908 nm Nd:YLF fundamental laser for both quasi-cw and cw conditions.

  19. Observations Of General Learning Patterns In An Upper-Level Thermal Physics Course

    Science.gov (United States)

    Meltzer, David E.

    2009-11-01

    I discuss some observations from using interactive-engagement instructional methods in an upper-level thermal physics course over a two-year period. From the standpoint of the subject matter knowledge of the upper-level students, there was a striking persistence of common learning difficulties previously observed in students enrolled in the introductory course, accompanied, however, by some notable contrasts between the groups. More broadly, I comment on comparisons and contrasts regarding general pedagogical issues among different student sub-populations, for example: differences in the receptivity of lower- and upper-level students to diagrammatic representations; varying receptivity to tutorial-style instructional approach within the upper-level population; and contrasting approaches to learning among physics and engineering sub-populations in the upper-level course with regard to use of symbolic notation, mathematical equations, and readiness to employ verbal explanations.

  20. Passive synchronized Q-switching between a quasi-three-level and a four-level laser

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Tidemand-Lichtenberg, Peter; Jensen, Ole Bjarlin

    2011-01-01

    Synchronized Q-switching between quasi-three-level and four-level lasers is interesting for sum-frequency generation into the blue and ultraviolet. We report, for the first time, stable synchronized Q-switching between a quasi-three-level laser at 946 nm and a four-level laser at 1064 nm in an all...

  1. Laser techniques for spectroscopy of core-excited atomic levels

    Science.gov (United States)

    Harris, S. E.; Young, J. F.; Falcone, R. W.; Rothenberg, J. E.; Willison, J. R.

    1982-01-01

    We discuss three techniques which allow the use of tunable lasers for high resolution and picosecond time scale spectroscopy of core-excited atomic levels. These are: anti-Stokes absorption spectroscopy, laser induced emission from metastable levels, and laser designation of selected core-excited levels.

  2. The Role of Low-Level Laser in Periodontal Surgeries

    Science.gov (United States)

    Sobouti, Farhad; Khatami, Maziar; Heydari, Mohaddase; Barati, Maryam

    2015-01-01

    Treatment protocols with low-level Laser (also called ‘soft laser therapy) have been used in health care systems for more than three decades. Bearing in mind the suitable sub-cellular absorption and the cellular-vascular impacts, low-level laser may be a treatment of choice for soft tissues. Low-level lasers have played crucial and colorful roles in performing periodontal surgeries. Their anti-inflammatory and painless effects have been variously reported in in-vitro studies. In this present review article, searches have been made in Pub Med, Google Scholar, and Science Direct, focusing on the studies which included low-level lasers, flap-periodontal surgeries, gingivectomy, and periodontal graft. The present study has sought to review the cellular impacts of low-level lasers and its role on reducing pain and inflammation following soft tissue surgical treatments. PMID:25987968

  3. Teaching Astrophysics to Upper Level Undergraduates

    Science.gov (United States)

    Van Dorn Bradt, Hale

    2010-03-01

    A Socratic peer-instruction method for teaching upper level undergraduates is presented. Basically, the instructor sits with the students and guides their presentations of the material. My two textbooks* (on display) as well as many others are amenable to this type of teaching. *Astronomy Methods - A Physical Approach to Astronomical Observations (CUP 2004) *Astrophysics Processes-The Physics of Astronomical Phenomena (CUP 2008)

  4. Only lasers can be used for low level laser therapy.

    Science.gov (United States)

    Moskvin, Sergey Vladimirovich

    2017-12-01

    The question of lasers' exclusivity, as well as the degree of influence of special properties of low-intensity laser illumination (LILI), such as coherence, polarity and monochromaticity, on the effectiveness of low level laser therapy (LLLT) continues to cause arguments. The study analyzes publications from 1973 to 2016, in which laser and conventional light sources are compared, and the following conclusions are drawn. First, there are a lot of publications with incorrect comparison or unfounded statements. Secondly, other sources of light are often meant by LILI without any justification. Thirdly, all studies, in which the comparison is carried out correctly and close parameters of the impact and the model are used, have a firm conclusion that laser light is much more effective. Fourthly, it is uniquely identified that the most important parameter that determines the efficiency of lasers is monochromaticity, i.e., a much narrower spectral width than for all other light sources. Only laser light sources can be used for LLLT! © Author(s) 2017. This article is published with open access by China Medical University.

  5. Medium-level laser in chronic tinnitus treatment.

    Science.gov (United States)

    Dejakum, K; Piegger, J; Plewka, C; Gunkel, A; Thumfart, W; Kudaibergenova, S; Goebel, G; Kral, F; Freysinger, W

    2013-01-01

    The purpose of this study was to evaluate the effect of medium-level laser therapy in chronic tinnitus treatment. In a prospective double-blind placebo-controlled trial, either active laser (450 mW, 830 nm combined Ga-Al-As diode laser) or placebo irradiation was applied through the external acoustic meatus of the affected ear towards the cochlea. Fourty-eight patients with chronic tinnitus were studied. The main outcome was measured using the Goebel tinnitus questionnaire, visual analogue scales measuring the perceived loudness of tinnitus, the annoyance associated with tinnitus, and the degree of attention paid to tinnitus as well as psycho-acoustical matches of tinnitus pitch and loudness. The results did show only very moderate temporary improvement of tinnitus. Moreover, no statistically relevant differences between laser and placebo group could be found. We conclude that medium-level laser therapy cannot be regarded as an effective treatment of chronic tinnitus in our therapy regime considering the limited number of patients included in our study.

  6. Internal attachment of laser beam welded stainless steel sheathed thermocouples into stainless steel upper end caps in nuclear fuel rods for the LOFT Reactor

    International Nuclear Information System (INIS)

    Welty, R.K.; Reid, R.D.

    1980-01-01

    The Exxon Nuclear Company, Inc., acting as a subcontractor to EG and G Idaho Inc., Idaho National Engineering Laboratory, Idaho Falls, Idaho, conducted a laser beam welding study to attach internal stainless steel thermocouples into stainless steel upper end caps in nuclear fuel rods. The objective of this study was to determine the feasibility of laser welding a single 0.063 inch diameter stainless steel (304) sheathed thermocouple into a stainless steel (316) upper end cap for nuclear fuel rods. A laser beam was selected because of the extremely high energy input in unit volume that can be achieved allowing local fusion of a small area irrespective of the difference in material thickness to be joined. A special weld fixture was designed and fabricated to hold the end cap and the thermocouple with angular and rotational adjustment under the laser beam. A commercial pulsed laser and energy control system was used to make the welds

  7. Effectiveness of low-level laser therapy for patients with carpal tunnel syndrome: design of a randomized single-blinded controlled trial

    Directory of Open Access Journals (Sweden)

    Barbosa Rafael Inácio

    2012-12-01

    Full Text Available Abstract Background Carpal tunnel syndrome is the most common neuropathy in the upper extremity, resulting from the compression of the median nerve at wrist level. Clinical studies are essentials to present evidence on therapeutic resources use at early restoration on peripheral nerve functionality. Low-level laser therapy has been widely investigated in researches related to nerve regeneration. Therefore, it is suggested that the effect of low-level laser therapy associated with other conservative rehabilitation techniques may positively affect symptoms and overall hand function in compressive neuropathies such as carpal tunnel syndrome. The aim of this study is to evaluate the effectiveness of low-level laser therapy in addition to orthoses therapy and home orientations in patients with carpal tunnel syndrome. Methods/Design Patients older than 18 years old will be included, with clinical diagnosis of carpal tunnel syndrome, excluding comorbidies. A physiotherapist will conduct intervention, with a blinding evaluator. Randomization will be applied to allocate the patients in each group: with association or not to low-level laser therapy. All of them will be submitted to orthoses therapy and home orientations. Outcome will be assessed through: pain visual analogic scale, Semmes Weinstein monofilaments™ threshold sensibility test, Pinch Gauge™, Boston Carpal Tunnel Questionnaire and two point discrimination test. Discussion This paper describes the design of a randomized controlled trial, which aim to assess the effectiveness of conservative treatment added to low-level laser therapy for patients with carpal tunnel syndrome. Trial registration Brazilian Clinical Trials Registry (ReBec - 75ddtf / Universal Trial Number: U1111-1121-5184

  8. Medium-Level Laser in Chronic Tinnitus Treatment

    Directory of Open Access Journals (Sweden)

    K. Dejakum

    2013-01-01

    Full Text Available The purpose of this study was to evaluate the effect of medium-level laser therapy in chronic tinnitus treatment. In a prospective double-blind placebo-controlled trial, either active laser (450 mW, 830 nm combined Ga-Al-As diode laser or placebo irradiation was applied through the external acoustic meatus of the affected ear towards the cochlea. Fourty-eight patients with chronic tinnitus were studied. The main outcome was measured using the Goebel tinnitus questionnaire, visual analogue scales measuring the perceived loudness of tinnitus, the annoyance associated with tinnitus, and the degree of attention paid to tinnitus as well as psycho-acoustical matches of tinnitus pitch and loudness. The results did show only very moderate temporary improvement of tinnitus. Moreover, no statistically relevant differences between laser and placebo group could be found. We conclude that medium-level laser therapy cannot be regarded as an effective treatment of chronic tinnitus in our therapy regime considering the limited number of patients included in our study.

  9. Excitation mechanisms in singly ionized krypton laser

    International Nuclear Information System (INIS)

    El-Sherbini, Th.M.

    1982-01-01

    Lifetimes for the low lying 4p 4 4d and 4p 4 5s levels of singly ionized krypton laser are calculated, taking into account configuration interaction effects. The results show that some of these levels are metastable. They also suggest a two step excitation from the ground state of the ion (or the atom) to the upper 4p 4 5p laser levels involving some intermediate metastable states as a possible excitation mechanism. (author)

  10. The Laser Level as an Optics Laboratory Tool

    Science.gov (United States)

    Kutzner, Mickey

    2013-01-01

    For decades now, the laser has been used as a handy device for performing ray traces in geometrical optics demonstrations and laboratories. For many ray- trace applications, I have found the laser level 3 to be even more visually compelling and easy for student use than the laser pointer.

  11. Infrared radiation and inversion population of CO2 laser levels in Venusian and Martian atmospheres

    Science.gov (United States)

    Gordiyets, B. F.; Panchenko, V. Y.

    1983-01-01

    Formation mechanisms of nonequilibrium 10 micron CO2 molecule radiation and the possible existence of a natural laser effect in the upper atmospheres of Venus and Mars are theoretically studied. An analysis is made of the excitation process of CO2 molecule vibrational-band levels (with natural isotropic content) induced by direct solar radiation in bands 10.6, 9.4, 4.3, 2.7 and 2.0 microns. The model of partial vibrational-band temperatures was used in the case. The problem of IR radiation transfer in vibrational-rotational bands was solved in the radiation escape approximation.

  12. Medium-Level Laser in Chronic Tinnitus Treatment

    OpenAIRE

    Dejakum, K.; Piegger, J.; Plewka, C.; Gunkel, A.; Thumfart, W.; Kudaibergenova, S.; Goebel, G.; Kral, F.; Freysinger, W.

    2013-01-01

    The purpose of this study was to evaluate the effect of medium-level laser therapy in chronic tinnitus treatment. In a prospective double-blind placebo-controlled trial, either active laser (450 mW, 830 nm combined Ga-Al-As diode laser) or placebo irradiation was applied through the external acoustic meatus of the affected ear towards the cochlea. Fourty-eight patients with chronic tinnitus were studied. The main outcome was measured using the Goebel tinnitus questionnaire, visual analogue sc...

  13. Progressive Derechos in the Presence of Closed Upper-level Subtropical Anticyclones

    Science.gov (United States)

    Guastini, C.; Bosart, L. F.

    2013-12-01

    Progressive derechos are a type of long-lived mesoscale convective system that produces large swaths of wind damage. In contrast to their serial derecho counterparts, which form in association with extratropical cyclones, progressive derechos often occur in the presence of benign synoptic conditions on the poleward side of closed upper-level subtropical anticyclones. Forecasters have been known to struggle predicting progressive derechos with any certainty due to the common lack of large-scale support for severe weather in regimes dominated by anticyclonic conditions. This study will classify a group of days on which there was a closed upper-level anticyclone over the United States and a progressive derecho did not occur and a group of days on which there was a closed upper-level anticyclone over the United States and a progressive derecho did occur, examine the synoptic environments of the two groups, and identify derecho null cases. By analyzing the null cases, derecho failure modes will be determined, which will help forecaster situational awareness and reveal the science behind the environmental conditions necessary for, and detrimental to, derecho development. This presentation will include climatologies of both derechos and closed upper-level anticyclones over the United States for June, July, and August of the years 1994-2013 (the modern radar era). The presentation will also include closed anticyclone-relative composites of both derecho cases and derecho null cases. The composites will elucidate which conditions are necessary for, and which are detrimental to, derecho development. The hypothesis is that derecho failure days occur due either to the lack of a triggering mechanism or other phenomena working against convective development such as a strong capping inversion or transverse ageostrophic circulations around an upper-level jet creating subsidence in an otherwise favorable environment. A representative case study will be included to highlight a common

  14. Role of laser fluence in protein synthesis of cultured DRG neurons following low-level laser irradiation

    Science.gov (United States)

    Zheng, Liqin; Qiu, Caimin; Wang, Yuhua; Zeng, Yixiu; Yang, Hongqin; Zhang, Yanding; Xie, Shusen

    2014-11-01

    Low-level lasers have been used to relieve pain in clinical for many years. But the mechanism is not fully clear. In animal models, nitric oxide (NO) has been reported involving in the transmission and modulation of nociceptive signals. So the objective of this study was to establish whether low-level laser with different fluence could stimulate the production of nitric oxide synthese (NOS), which produces NO in cultured primary dorsal root ganglion neurons (DRG neurons). The primary DRG neurons were isolated from healthy Sprague Dawley rats (8-12 weeks of age) and spread on 35 mm culture dishes specially used for confocal microscopy. 24 hours after spreading, cells were irradiated with 658 nm laser for two consecutive days at the energy density of 20, 40, 60 and 80 mJ·cm-2 respectively. Control groups were not exposed to the laser, but were kept under the same conditions as the irradiated ones. The synthesis of NOS after laser irradiation was detected by immunofluorescence assay, and the changes of NOS were evaluated using confocal microscopy and Image J software. The results showed that all the laser fluence could promote the production of NOS in DRG neurons, especially the 60 mJ·cm-2 . These results demonstrated that low-level laser irradiation could modify protein synthesis in a dose- or fluence- dependent manner, and indicated that low-level laser irradiation might achieve the analgesic effect through modulation of NO production.

  15. Electrically pumped graphene-based Landau-level laser

    Science.gov (United States)

    Brem, Samuel; Wendler, Florian; Winnerl, Stephan; Malic, Ermin

    2018-03-01

    Graphene exhibits a nonequidistant Landau quantization with tunable Landau-level (LL) transitions in the technologically desired terahertz spectral range. Here, we present a strategy for an electrically driven terahertz laser based on Landau-quantized graphene as the gain medium. Performing microscopic modeling of the coupled electron, phonon, and photon dynamics in such a laser, we reveal that an inter-LL population inversion can be achieved resulting in the emission of coherent terahertz radiation. The presented paper provides a concrete recipe for the experimental realization of tunable graphene-based terahertz laser systems.

  16. Upper-Level Undergraduate Chemistry Students' Goals for Their Laboratory Coursework

    Science.gov (United States)

    DeKorver, Brittland K.; Towns, Marcy H.

    2016-01-01

    Efforts to reform undergraduate chemistry laboratory coursework typically focus on the curricula of introductory-level courses, while upper-level courses are bypassed. This study used video-stimulated recall to interview 17 junior- and senior- level chemistry majors after they carried out an experiment as part of a laboratory course. It is assumed…

  17. Towards upper power levels: thermonuclear fusion

    International Nuclear Information System (INIS)

    Vedel, Jean

    1983-01-01

    This paper is a brief introduction to the use of power lasers to achieve controlled thermonuclear fusion. After shortly describing thermonuclear fusion and the conditions of temperature, density and duration required it is showed how the laser enables such conditions to be created. The neodymium-doped glass laser NOVA that is being installed at the Livermore laboratory in the USA is described; at the time of its completion in 1984, this laser will be the most powerful in the world. In comparison, the OCTAL laser in operation at the Limeil establishment ''Centre d'Etudes'' of ''Commissariat Francais a l'Energie Atomique'' (the French atomic energy authority) is more modest; it is presented here [fr

  18. Review of student difficulties in upper-level quantum mechanics

    Directory of Open Access Journals (Sweden)

    Chandralekha Singh

    2015-09-01

    Full Text Available [This paper is part of the Focused Collection on Upper Division Physics Courses.] Learning advanced physics, in general, is challenging not only due to the increased mathematical sophistication but also because one must continue to build on all of the prior knowledge acquired at the introductory and intermediate levels. In addition, learning quantum mechanics can be especially challenging because the paradigms of classical mechanics and quantum mechanics are very different. Here, we review research on student reasoning difficulties in learning upper-level quantum mechanics and research on students’ problem-solving and metacognitive skills in these courses. Some of these studies were multiuniversity investigations. The investigations suggest that there is large diversity in student performance in upper-level quantum mechanics regardless of the university, textbook, or instructor, and many students in these courses have not acquired a functional understanding of the fundamental concepts. The nature of reasoning difficulties in learning quantum mechanics is analogous to reasoning difficulties found via research in introductory physics courses. The reasoning difficulties were often due to overgeneralizations of concepts learned in one context to another context where they are not directly applicable. Reasoning difficulties in distinguishing between closely related concepts and in making sense of the formalism of quantum mechanics were common. We conclude with a brief summary of the research-based approaches that take advantage of research on student difficulties in order to improve teaching and learning of quantum mechanics.

  19. Computational model of dual q-switching and lasing processes of the pulsed Cr4+:YAG laser pumped by Nd-glass laser

    International Nuclear Information System (INIS)

    Abdul Ghani, B.; Hammadi, M.

    2007-01-01

    A mathematical model describing the absorption and oscillation processes of intracavity Cr 4+ : YAG crystal pumped by Nd-glass laser has been developed, in order to describe the temporal behavior of laser-absorber system. The model has been assumed that the Cr 4+ ions excited to a higher level by excited state absorption, followed by relaxation directly to the upper laser level through fast channel, and indirectly through slow proposed intermediate channel at different lifetimes. The model offers simple kinetic mechanisms for pulsed solid state lasers and also the influence of the variations of the laser input parameters (pumping rate, maximum amplification coefficient and loss coefficient) on the output pulse characteristics of the passive Q-switched Nd-glass and pulsed Cr 4+ : YAG lasers. The model estimates the temporal behavior of the population densities of different levels and laser beam densities as well as predicts the nanosecond output laser pulses of passive Q-switched Nd-glass laser and pulsed Cr 4+ : YAG laser. The calculated results are in good agreement with the available experimental and theoretical data in the literature. (author)

  20. Low-level lasers affect Escherichia coli cultures in hyperosmotic stress

    Science.gov (United States)

    Pinheiro, C. C.; Barboza, L. L.; Paoli, F.; Fonseca, A. S.

    2015-08-01

    Physical characteristics and practical properties have made lasers of interest for biomedical applications. Effects of low-level lasers on biological tissues could occur or be measurable depending on cell type, presence of a pathologic process or whether the cells are in an adverse environment. The objective of this work was to evaluate the survival, morphology and filamentation of E. coli cells proficient and deficient in the repair of oxidative DNA lesions exposed low-level red and infrared lasers submitted to hyperosmotic stress. Wild type and endonuclease VIII deficient E. coli cells in exponential and stationary growth phase were exposed to red and infrared lasers and submitted to hyperosmotic stress. Cell viability, filamentation phenotype and cell morphology were evaluated. Cell viability was not significantly altered but previous laser exposure induced filamentation and an altered area of stressed cells depending on physiologic condition and presence of the DNA repair. Results suggest that previous exposure to low-level red and infrared lasers could not affect viability but induced morphologic changes in cells submitted to hyperosmotic stress depending on physiologic conditions and repair of oxidative DNA lesions.

  1. Low-level lasers on microRNA and uncoupling protein 2 mRNA levels in human breast cancer cells

    Science.gov (United States)

    Canuto, K. S.; Teixeira, A. F.; Rodrigues, J. A.; Paoli, F.; Nogueira, E. M.; Mencalha, A. L.; Fonseca, A. S.

    2017-06-01

    MicroRNA is short non-coding RNA and is a mediator of post-transcriptional regulation of gene expression. In addition, uncoupling proteins (UCPs) regulate thermogenesis, metabolic and energy balance, and decrease reactive oxygen species production. Both microRNA and UCP2 expression can be altered in cancer cells. At low power, laser wavelength, frequency, fluence and emission mode deternube photobiological responses, which are the basis of low-level laser therapy. There are few studies on miRNA and UCP mRNA levels after low-level laser exposure on cancer cells. In this work, we evaluate the micrRNA (mir-106b and mir-15a) and UCP2 mRNA levels in human breast cancer cells exposed to low-level lasers. MDA-MB-231 human breast cancer cells were exposed to low-level red and infrared lasers, total RNA was extracted for cDNA synthesis and mRNA levels by real time quantitative polymerase chain reaction were evaluated. Data show that mir-106b and mir-15a relative levels are not altered, but UCP2 mRNA relative levels are increased in MDA-MB-231 human breast cancer cells exposed to low-level red and infrared lasers at fluences used in therapeutic protocols.

  2. Measurements of low-level prepulse on Nike KrF laser

    International Nuclear Information System (INIS)

    Karasik, Max; Mostovych, A.N.; Lehmberg, R.H.; Chan, Y.; Weaver, J.L.; Obenschain, S.P.

    2005-01-01

    The krypton fluoride (KrF) laser is a leading candidate driver for inertial fusion energy. Some of the current fusion target designs call for targets with thin metallic coatings. These targets could be particularly susceptible to preheat by a low-level laser prepulse. Knowledge of the prepulse can be important in understanding and modeling the behavior of such targets. This paper presents measurements of low-level prepulse on target with the Nike KrF laser. Sources of prepulse are discussed and measurements are performed under several specific laser conditions in order to evaluate the relative contribution of these sources to the overall prepulse. Prepulse is found to be ∼2x10 -7 from peak intensity for approximately 120 ns prior to the main laser pulse. Prepulse energy density on target is ∼2 J/cm 2 . The first laser amplifier in the time- and angle-multiplexed section of the laser is found to be the dominant source of prepulse

  3. The upper level of control system of electron accelerators

    International Nuclear Information System (INIS)

    Gribov, I.V.; Nedeoglo, F.N.; Shvedunov, I.V.

    2005-01-01

    The upper level software of a three-level control system that supports several electron accelerators is described. This software operates in the Linux and RTLinux (Real Time Linux) environment. The object information model functions on the basis of a parametric description supported by the SQLite Data Base Management System. The Javascript sublanguage is used for script forming, and the Qt Designer application is used to construct the user interface [ru

  4. Comparison the Serum STREM1 Levels Between Children with Upper and Lower UTI.

    Science.gov (United States)

    Ehsanipour, Fahime; Noorbakhsh, Samileh; Zarabi, Vida; Movahedi, Zahra; Rahimzadeh, Nahid

    2017-01-01

    Pyelonephritis is the most common and important infection among Iranian pediatric population. Differentiation between upper and lower Urinary Tract Infection (UTI) is often difficult based on clinical data. Therefore, definite diagnosis is helpful for choosing appropriate antibiotic and decision for hospital admission. The main purpose of this study was todetermine the diagnostic value of serum STREM-1 level in children suspicious to UTI and differentiation of upper UTI and lower UTI. This prospective cross sectional study (2010-2011) was performed to evaluate and compare the serum level of STREM- 1 (pg. /ml) in 36 diagnosed UTI patients (24 upper and 12 lower UTI) with 25 normal children (without UTI) in Rasoul Akram hospital, Tehran, Iran. The mean age of studied children was 3.64 years; 24 male and 37 female. Urinary analysis and urine culture were performed for all UTI cases and only the positive cultured cases with the same microorganism were enrolled in the study. Distinguishing the upper from lower UTI was done on the basis of clinical manifestation and laboratory tests and confirmed by Imaging studies (ultra sonography /or DMSA scan). Blood sampling was taken from all children and centrifuged .The level of STREM-1 (pg /ml) in all sera was determined by Enzyme immunoassay technique (Human TREM-1 immunoassay Sandwich test, Quantikine, R&D systems, Minneapolis; USA). Cut-off levels for STREM-1 were illustrated by ROC curve. The pUTI (427.72pg/ml) and controls (124.24 pg. /ml; P =0.000) ; with cutoff point 111.5 pg./ml ; it had 83.3% sensitivity; and 60 % specificity to distinguish UTI from control. Serum STREM -1 level had no significantly difference between the upper and lower UTI (500pg/ml vs. 283 pg. /ml, P value=0.1) with cutoff point 132 pg./ml it had 83.3% sensitivity ; and 60 % specificity to distinguish upper UTI from lower UTI. Our study demonstrates that even low amount of serum STREM-1 (111.5 pg./ml) has 83.3% sensitivity ; and 60 % specificity to

  5. Low-level lasers alter mRNA levels from traditional reference genes used in breast cancer cells

    Science.gov (United States)

    Teixeira, A. F.; Canuto, K. S.; Rodrigues, J. A.; Fonseca, A. S.; Mencalha, A. L.

    2017-07-01

    Cancer is among the leading causes of mortality worldwide, increasing the importance of treatment development. Low-level lasers are used in several diseases, but some concerns remains on cancers. Reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) is a technique used to understand cellular behavior through quantification of mRNA levels. Output data from target genes are commonly relative to a reference that cannot vary according to treatment. This study evaluated reference genes levels from MDA-MB-231 cells exposed to red or infrared lasers at different fluences. Cultures were exposed to red and infrared lasers, incubated (4 h, 37 °C), total RNA was extracted and cDNA synthesis was performed to evaluate mRNA levels from ACTB, GUSB and TRFC genes by RT-qPCR. Specific amplification was verified by melting curves and agarose gel electrophoresis. RefFinder enabled data analysis by geNorm, NormFinder and BestKeeper. Specific amplifications were obtained and, although mRNA levels from ACTB, GUSB or TRFC genes presented no significant variation through traditional statistical analysis, Excel-based tools revealed that the use of these reference genes are dependent of laser characteristics. Our data showed that exposure to low-level red and infrared lasers at different fluences alter the mRNA levels from ACTB, GUSB and TRFC in MDA-MB-231 cells.

  6. Excitation mechanisms for XUV and X-ray lasers

    International Nuclear Information System (INIS)

    El-Sherbini, T.M.; Arrubban, M.M.

    1992-01-01

    Two excitation mechanisms leading to lasing action in the extreme ultraviolet and soft X-ray spectral regions are proposed. Boron- like ions of Mg VIII, Al IX and Si X plasmas are used as the active laser material. The upper laser level is the metastable 1s 2 2s 2 4p( 2 p) state while the lower level is the short lived 1s 2 2s 2 3d( 2 D) state. (author). 10 refs, 1 fig., 3 tabs

  7. Low-level laser therapy and Calendula officinalis in repairing diabetic foot ulcers

    Directory of Open Access Journals (Sweden)

    Ana Flávia Machado de Carvalho

    Full Text Available Abstract OBJECTIVE To evaluate the effects of low-level laser therapy isolated and associated with Calendula officinalis oil in treating diabetic foot ulcers. METHOD An experimental, randomized, controlled, prospective, interventional clinical case study using a quantitative approach. The sample consisted of 32 diabetic patients of both genders. Participants were randomly divided into four groups. Doppler Ultrasound evaluation of the Ankle-Brachial Index, brief pain inventory and analog pain scale were performed at baseline and after 30 days. RESULTS Reduced pain was observed in the Low-level laser therapy and Low-level laser therapy associated with Essential Fatty Acids groups (p<0.01. Regarding the Ankle-Brachial Index and Doppler Ultrasound, all groups remained stable. By analyzing lesion area reduction, Low-level laser therapy associated with Essential fatty acids group showed a significance of p=0.0032, and the Low-level laser therapy group showed p=0.0428. CONCLUSION Low-level laser therapy, performed alone or associated with the Calendula officinalis oil was effective in relieving pain and accelerating the tissue repair process of diabetic foot.

  8. Evaluation of the Barr & Stroud FP15 and Criterion 400 laser dendrometers for measuring upper stem diameters and heights

    Science.gov (United States)

    Michael S. Williams; Kenneth L. Cormier; Ronald G. Briggs; Donald L. Martinez

    1999-01-01

    Calibrated Barr & Stroud FP15 and Criterion 400 laser dendrometers were tested for reliability in measuring upper stem diameters and heights under typical field conditions. Data were collected in the Black Hills National Forest, which covers parts of South Dakota and Wyoming in the United States. Mixed effects models were employed to account for differences between...

  9. Groundwater levels for selected wells in Upper Kittitas County, Washington

    Science.gov (United States)

    Fasser, E.T.; Julich, R.J.

    2011-01-01

    Groundwater levels for selected wells in Upper Kittitas County, Washington, are presented on an interactive, web-based map to document the spatial distribution of groundwater levels in the study area measured during spring 2011. Groundwater-level data and well information were collected by the U.S. Geological Survey using standard techniques and are stored in the U.S. Geological Survey National Water Information System, Groundwater Site-Inventory database.

  10. [The new potentials of magneto-laser therapy and electrostimulation in children with cleft palate and upper lip].

    Science.gov (United States)

    Gerasimenko, M Iu; Filatova, E V; Borisenko, O V; Levchenkova, V D; Grishina, N V; Spiridonova, N Z; Shevchenko, E Iu; Goncharenko, L L

    2000-01-01

    The paper presents rationale for design of new procedures of physiotherapy in children with expanded palate and upper lip; morphofunctional features of prenatal and early postnatal formation of central nervous system; a multilayer technique of magneto-laser radiation to the projection of the anterior central gyrus and the technique of electrostimulation by the system of the wink reflex which can influence central mechanisms of regulation and adaptation before and early after uranoplasty and cheiloplasty.

  11. Upper Secondary and Vocational Level Teachers at Social Software

    Science.gov (United States)

    Valtonen, Teemu; Kontkanen, Sini; Dillon, Patrick; Kukkonen, Jari; Väisänen, Pertti

    2014-01-01

    This study focuses on upper secondary and vocational level teachers as users of social software i.e. what software they use during their leisure and work and for what purposes they use software in teaching. The study is theorised within a technological pedagogical content knowledge framework, the emphasis is especially on technological knowledge…

  12. Pulsed low-level infrared laser alters mRNA levels from muscle repair genes dependent on power output in Wistar rats

    Science.gov (United States)

    Trajano, L. A. S. N.; Trajano, E. T. L.; Thomé, A. M. C.; Sergio, L. P. S.; Mencalha, A. L.; Stumbo, A. C.; Fonseca, A. S.

    2017-10-01

    Satellite cells are present in skeletal muscle functioning in the repair and regeneration of muscle injury. Activation of these cells depends on the expression of myogenic factor 5 (Myf5), myogenic determination factor 1(MyoD), myogenic regulatory factor 4 (MRF4), myogenin (MyoG), paired box transcription factors 3 (Pax3), and 7 (Pax7). Low-level laser irradiation accelerates the repair of muscle injuries. However, data from the expression of myogenic factors have been controversial. Furthermore, the effects of different laser beam powers on the repair of muscle injuries have been not evaluated. The aim of this study was to evaluate the effects of low-level infrared laser at different powers and in pulsed emission mode on the expression of myogenic regulatory factors and on Pax3 and Pax7 in injured skeletal muscle from Wistar rats. Animals that underwent cryoinjury were divided into three groups: injury, injury laser 25 Mw, and injury laser 75 mW. Low-level infrared laser irradiation (904 nm, 3 J cm-2, 5 kHz) was carried out at 25 and 75 mW. After euthanasia, skeletal muscle samples were withdrawn and the total RNA was extracted for the evaluation of mRNA levels from the MyoD, MyoG, MRF4, Myf5, Pax3, and Pax7 gene. Pax 7 mRNA levels did not alter, but Pax3 mRNA levels increased in the injured and laser-irradiated group at 25 mW. MyoD, MyoG, and MYf5 mRNA levels increased in the injured and laser-irradiated animals at both powers, and MRF4 mRNA levels decreased in the injured and laser-irradiated group at 75 mW. In conclusion, exposure to pulsed low-level infrared laser, by power-dependent effect, could accelerate the muscle repair process altering mRNA levels from paired box transcription factors and myogenic regulatory factors.

  13. Efficient quasi-three-level Nd:YAG laser at 946 nm pumped by a tunable external cavity tapered diode laser

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Jensen, Ole Bjarlin; Tidemand-Lichtenberg, Peter

    2010-01-01

    Using a tunable external cavity tapered diode laser (ECDL) pumped quasi-three-level Nd:YAG laser, a fivefold reduction in threshold and twofold increase in slope efficiency is demonstrated when compared to a traditional broad area diode laser pump source. A TEM00 power of 800 mW with 65% slope...... efficiency is obtained, the highest reported TEM00 power from any 946 nm Nd:YAG laser pumped by a single emitter diode laser pump source. A quantum efficiency of 0.85 has been estimated from experimental data using a simple quasi-three-level model. The reported value is in good agreement with published...

  14. Physics Identity Development: A Snapshot of the Stages of Development of Upper-Level Physics Students

    Science.gov (United States)

    Irving, Paul W.; Sayre, Eleanor C.

    2013-01-01

    As part of a longitudinal study into identity development in upper-level physics students a phenomenographic research method is employed to assess the stages of identity development of a group of upper-level students. Three categories of description were discovered which indicate the three different stages of identity development for this group…

  15. Effect of low-level laser-treated mesenchymal stem cells on myocardial infarction.

    Science.gov (United States)

    El Gammal, Zaynab H; Zaher, Amr M; El-Badri, Nagwa

    2017-09-01

    Cardiovascular disease is the leading cause of death worldwide. Although cardiac transplantation is considered the most effective therapy for end-stage cardiac diseases, it is limited by the availability of matching donors and the complications of the immune suppressive regimen used to prevent graft rejection. Application of stem cell therapy in experimental animal models was shown to reverse cardiac remodeling, attenuate cardiac fibrosis, improve heart functions, and stimulate angiogenesis. The efficacy of stem cell therapy can be amplified by low-level laser radiation. It is well established that the bio-stimulatory effect of low-level laser is influenced by the following parameters: wavelength, power density, duration, energy density, delivery time, and the type of irradiated target. In this review, we evaluate the available experimental data on treatment of myocardial infarction using low-level laser. Eligible papers were characterized as in vivo experimental studies that evaluated the use of low-level laser therapy on stem cells in order to attenuate myocardial infarction. The following descriptors were used separately and in combination: laser therapy, low-level laser, low-power laser, stem cell, and myocardial infarction. The assessed low-level laser parameters were wavelength (635-804 nm), power density (6-50 mW/cm 2 ), duration (20-150 s), energy density (0.96-1 J/cm 2 ), delivery time (20 min-3 weeks after myocardial infarction), and the type of irradiated target (bone marrow or in vitro-cultured bone marrow mesenchymal stem cells). The analysis focused on the cardioprotective effect of this form of therapy, the attenuation of scar tissue, and the enhancement of angiogenesis as primary targets. Other effects such as cell survival, cell differentiation, and homing are also included. Among the evaluated protocols using different parameters, the best outcome for treating myocardial infarction was achieved by treating the bone marrow by one dose of low-level

  16. The influence of tropospheric static stability on upper-level frontogenesis

    OpenAIRE

    Saute, Marcel

    2011-01-01

    Upper-level frontogenesis in an inviscid, dry and adiabatic fluid forced by confluence is investigated by means of a two-dimensional semi-geostrophic model using the specific volume as an isentropic vertical coordinate. The initial conditions are specified given an analytical continuous potential vorticity field in the presence of a temperature contrast at the ground, the lower boundary condition requiring an appropriate treatment because the ground intersects the first levels of the model. T...

  17. Increased ionization rate in laser enrichment

    International Nuclear Information System (INIS)

    Janes, G.S.; Pike, G.T.

    1977-01-01

    A system employing multiple, upper excitation levels in a technique for isotopically selective ionization to improve the ionization efficiency is described. Laser radiation is employed to excite particles with isotopic selectivity. Excitation is produced to a plurality of excited states below the ionization level with the result of increasing the number of available excited particles for ionization and thereby increasing the ionization cross section for improved system efficiency

  18. Indirect measurement of molten steel level in tundish based on laser triangulation

    Science.gov (United States)

    Su, Zhiqi; He, Qing; Xie, Zhi

    2016-03-01

    For real-time and precise measurement of molten steel level in tundish during continuous casting, slag level and slag thickness are needed. Among which, the problem of slag thickness measurement has been solved in our previous work. In this paper, a systematic solution for slag level measurement based on laser triangulation is proposed. Being different from traditional laser triangulation, several aspects for measuring precision and robustness have been done. First, laser line is adopted for multi-position measurement to overcome the deficiency of single point laser range finder caused by the uneven surface of the slag. Second, the key parameters, such as installing angle and minimum requirement of the laser power, are analyzed and determined based on the gray-body radiation theory to fulfill the rigorous requirement of measurement accuracy. Third, two kinds of severe noises in the acquired images, which are, respectively, caused by heat radiation and Electro-Magnetic Interference (EMI), are cleaned via morphological characteristic of the liquid slag and color difference between EMI and the laser signals, respectively. Fourth, as false target created by stationary slag usually disorders the measurement, valid signals of the slag are distinguished from the false ones to calculate the slag level. Then, molten steel level is obtained by the slag level minus the slag thickness. The measuring error of this solution is verified by the applications in steel plants, which is ±2.5 mm during steady casting and ±3.2 mm at the end of casting.

  19. Indirect measurement of molten steel level in tundish based on laser triangulation

    Energy Technology Data Exchange (ETDEWEB)

    Su, Zhiqi; He, Qing, E-mail: heqing@ise.neu.edu.cn; Xie, Zhi [State Key Laboratory of Synthetical Automation for Process Industries, School of Information Science and Engineering, Northeastern University, Shenyang 110819 (China)

    2016-03-15

    For real-time and precise measurement of molten steel level in tundish during continuous casting, slag level and slag thickness are needed. Among which, the problem of slag thickness measurement has been solved in our previous work. In this paper, a systematic solution for slag level measurement based on laser triangulation is proposed. Being different from traditional laser triangulation, several aspects for measuring precision and robustness have been done. First, laser line is adopted for multi-position measurement to overcome the deficiency of single point laser range finder caused by the uneven surface of the slag. Second, the key parameters, such as installing angle and minimum requirement of the laser power, are analyzed and determined based on the gray-body radiation theory to fulfill the rigorous requirement of measurement accuracy. Third, two kinds of severe noises in the acquired images, which are, respectively, caused by heat radiation and Electro-Magnetic Interference (EMI), are cleaned via morphological characteristic of the liquid slag and color difference between EMI and the laser signals, respectively. Fourth, as false target created by stationary slag usually disorders the measurement, valid signals of the slag are distinguished from the false ones to calculate the slag level. Then, molten steel level is obtained by the slag level minus the slag thickness. The measuring error of this solution is verified by the applications in steel plants, which is ±2.5 mm during steady casting and ±3.2 mm at the end of casting.

  20. Development and application of the variable focus laser leveling gage

    International Nuclear Information System (INIS)

    Gong Kun; Ma Jinglong

    2005-01-01

    The variable focus laser leveling gage was developed. The performance and structure were introduced. The several alignments and tests in KrF laser angle multi-path optical system were accomplished with them. Its application in other optical equipment was discussed too. (author)

  1. Acute effects of low-level laser therapy (660 nm) on oxidative stress levels in diabetic rats with skin wounds.

    Science.gov (United States)

    Denadai, Amanda Silveira; Aydos, Ricardo Dutra; Silva, Iandara Schettert; Olmedo, Larissa; de Senna Cardoso, Bruno Mendonça; da Silva, Baldomero Antonio Kato; de Carvalho, Paulo de Tarso Camillo

    2017-09-01

    Laser therapy influences oxidative stress parameters such as the activity of antioxidant enzymes and the production of reactive oxygen species. To analyze the effects of low-level laser therapy on oxidative stress in diabetics rats with skin wounds. Thirty-six animals were divided into 4 groups: NDNI: non-diabetic rats with cutaneous wounds that not received laser therapy; NDI: non-diabetic rats with cutaneous wounds that received laser therapy; DNI: diabetic rats with skin wounds who did not undergo laser therapy; DI: rats with diabetes insipidus and cutaneous wounds and received laser therapy. The animals were treated with LLLT (660 nm, 100 mW, 6 J/cm, spot size 0.028 cm). On the day of killing the animals, tissue-wrapped cutaneous wounds were collected and immediately frozen, centrifuged, and stored to analyze malondialdehyde (MDA) levels. Significant difference was observed within the groups of MDA levels (ANOVA, p = 0.0001). Tukey's post-hoc test showed significantly lower values of MDA in irradiated tissues, both in diabetic and non-diabetic rats. ANOVA of the diabetic group revealed a significant difference (p < 0.01) when all groups, except NDI and DI, were compared. LLLT was effective in decreasing MDA levels in acute surgical wounds in diabetic rats.

  2. Measuring Student Improvement in Lower- and Upper-Level University Climate Science Courses

    Science.gov (United States)

    Harris, S. E.; Taylor, S. V.; Schoonmaker, J. E.; Lane, E.; Francois, R. H.; Austin, P.

    2011-12-01

    What do university students know about climate? What do they learn in a climate course? On the second-to-last day of a course about global climate change, only 48% of our upper-level science students correctly answered a multiple-choice question about the greenhouse effect. The good news: improvement. Only 16% had answered correctly on the first day of class. The bad news: the learning opportunities we've provided appear to have missed more than half the class on a fundamental climate concept. To evaluate the effectiveness of instruction on student learning about climate, we have developed a prototype assessment tool, designed to be deployed as a low-stakes pre-post test. The items included were validated through student interviews to ensure that students interpret the wording and answer choices in the way we intend. This type of validated assessment, administered both at the beginning and end of term, with matched individuals, provides insight regarding the baseline knowledge with which our students enter a course, and the impact of that course on their learning. We administered test items to students in (1) an upper-level climate course for science majors and (2) a lower-level climate course open to all students. Some items were given to both groups, others to only one of the groups. Both courses use evidence-based pedagogy with active student engagement (clickers, small group activities, regular pre-class preparation). Our results with upper-level students show strong gains in student thinking (>70% of students who missed a question on the pre-test answered correctly on the post-test) about stock-and-flow (box model) problems, annual cycles in the Keeling curve, ice-albedo feedbacks, and isotopic fractionation. On different questions, lower-level students showed strong gains regarding albedo and blackbody emission spectra. Both groups show similar baseline knowledge and lower-than-expected gains on greenhouse effect fundamentals, and zero gain regarding the

  3. Low-level red laser therapy alters effects of ultraviolet C radiation on Escherichia coli cells

    International Nuclear Information System (INIS)

    Canuto, K.S.; Guimaraes, O.R.; Geller, M.; Sergio, L.P.S.; Paoli, F.; Fonseca, A.S.

    2015-01-01

    Low-level lasers are used at low power densities and doses according to clinical protocols supplied with laser devices or based on professional practice. Although use of these lasers is increasing in many countries, the molecular mechanisms involved in effects of low-level lasers, mainly on DNA, are controversial. In this study, we evaluated the effects of low-level red lasers on survival, filamentation, and morphology of Escherichia coli cells that were exposed to ultraviolet C (UVC) radiation. Exponential and stationary wild-type and uvrA-deficient E. coli cells were exposed to a low-level red laser and in sequence to UVC radiation. Bacterial survival was evaluated to determine the laser protection factor (ratio between the number of viable cells after exposure to the red laser and UVC and the number of viable cells after exposure to UVC). Bacterial filaments were counted to obtain the percentage of filamentation. Area-perimeter ratios were calculated for evaluation of cellular morphology. Experiments were carried out in duplicate and the results are reported as the means of three independent assays. Pre-exposure to a red laser protected wild-type and uvrA-deficient E. coli cells against the lethal effect of UVC radiation, and increased the percentage of filamentation and the area-perimeter ratio, depending on UVC fluence and physiological conditions in the cells. Therapeutic, low-level red laser radiation can induce DNA lesions at a sub-lethal level. Consequences to cells and tissues should be considered when clinical protocols based on this laser are carried out. (author)

  4. Low-level red laser therapy alters effects of ultraviolet C radiation on Escherichia coli cells

    Energy Technology Data Exchange (ETDEWEB)

    Canuto, K.S.; Guimaraes, O.R.; Geller, M. [Centro Universitario Serra dos Orgaos, Teresopolis, RJ (Brazil). Centro de Ciencias da Saude; Sergio, L.P.S. [Instituto de Biologia Roberto Alcantara Gomes, Rio de Janeiro, RJ (Brazil). Departamento de Biofisica e Biometria; Paoli, F. [Universidade Federal de Juiz de Fora (UFJF), Juiz de Fora, MG (Brazil). Departamento de Morfologia; Fonseca, A.S., E-mail: adnfonseca@ig.com.br [Universidade Federal do Estado do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Departamento de Ciencias Fisiologicas

    2015-10-15

    Low-level lasers are used at low power densities and doses according to clinical protocols supplied with laser devices or based on professional practice. Although use of these lasers is increasing in many countries, the molecular mechanisms involved in effects of low-level lasers, mainly on DNA, are controversial. In this study, we evaluated the effects of low-level red lasers on survival, filamentation, and morphology of Escherichia coli cells that were exposed to ultraviolet C (UVC) radiation. Exponential and stationary wild-type and uvrA-deficient E. coli cells were exposed to a low-level red laser and in sequence to UVC radiation. Bacterial survival was evaluated to determine the laser protection factor (ratio between the number of viable cells after exposure to the red laser and UVC and the number of viable cells after exposure to UVC). Bacterial filaments were counted to obtain the percentage of filamentation. Area-perimeter ratios were calculated for evaluation of cellular morphology. Experiments were carried out in duplicate and the results are reported as the means of three independent assays. Pre-exposure to a red laser protected wild-type and uvrA-deficient E. coli cells against the lethal effect of UVC radiation, and increased the percentage of filamentation and the area-perimeter ratio, depending on UVC fluence and physiological conditions in the cells. Therapeutic, low-level red laser radiation can induce DNA lesions at a sub-lethal level. Consequences to cells and tissues should be considered when clinical protocols based on this laser are carried out. (author)

  5. Evaluation procedure for Service Level C and D upper shelf toughness criteria for Linde 80 weld material

    International Nuclear Information System (INIS)

    Gamble, R.M.

    1993-09-01

    Procedures have been defined to evaluate the upper shelf toughness criteria recently defined by ASME Section XI Subgroup on Evaluation Standards for ASME Service Level C and D conditions. These procedures and the ASME criteria were applied to assess the upper toughness requirements for axial Linde 80 welds in a typical PWR reactor pressure vessel beltline geometry. Because there is a wide spectrum of possible Level C and D events, the evaluation was performed for a bounding thermal transient and results were obtained to determine allowable pressure versus upper shelf energy. The allowable pressure for the bounding thermal transient was found to be above normal operating pressure for upper shelf energies equal to and greater than 40 ft-lb. Because a bounding thermal transient was used, the allowable pressures determined in this work should be minimum values. The results from this work provide a screening criterion to quickly identify limiting transients that may require more detailed analysis and an analysis procedure to assess compliance with ASME upper shelf energy criteria for Service Level C and D events. For events with significant thermal transients, such as those evaluated in this work, the transient pressure typically decreases rapidly from normal operating pressure to 1,500 psi or less before the maximum thermal K I , is reached. Comparing this pressure range with the allowable pressure versus upper shelf energy curves determined in this work indicates that the transient pressures are significantly less than the allowables computed for Level C and D events; consequently, Level A/B conditions will likely dictate the upper shelf requirements for most applications

  6. Fostering Students' Preparation and Achievement in Upper Level Mathematics Courses

    Science.gov (United States)

    Celik, Mehmet; Shaqlaih, Ali

    2017-01-01

    This study describes an intervention to address both motivation, student engagement and preparation in upper-level mathematics courses. The effect of the intervention regarding students' achievements is investigated via students' opinions and data analysis from students' assessments. The results of this study show the featured intervention…

  7. Ultimate temperature for laser cooling of two-level neutral atoms

    International Nuclear Information System (INIS)

    Bagnato, V.S.; Zilio, S.C.

    1989-01-01

    We present a simple pedagogical method to evaluate the minimum attainable temperature for laser cooling of two-level neutral atoms. Results are given as a function of the laser detuning and intensity. We also discuss the use of this approach to predict the minimum temperature of neutral atoms confined in magnetic traps. (author) [pt

  8. Low-level laser therapy and Calendula officinalis in repairing diabetic foot ulcers.

    Science.gov (United States)

    Carvalho, Ana Flávia Machado de; Feitosa, Maura Cristina Porto; Coelho, Nayana Pinheiro Machado de Freitas; Rebêlo, Veruska Cronemberger Nogueira; Castro, Juçara Gonçalves de; Sousa, Patrícia Regina Gomes de; Feitosa, Valrian Campos; Arisawa, Emilia Angela Lo Schiavo

    2016-01-01

    To evaluate the effects of low-level laser therapy isolated and associated with Calendula officinalis oil in treating diabetic foot ulcers. An experimental, randomized, controlled, prospective, interventional clinical case study using a quantitative approach. The sample consisted of 32 diabetic patients of both genders. Participants were randomly divided into four groups. Doppler Ultrasound evaluation of the Ankle-Brachial Index, brief pain inventory and analog pain scale were performed at baseline and after 30 days. Reduced pain was observed in the Low-level laser therapy and Low-level laser therapy associated with Essential Fatty Acids groups (pgrupos. Ultrassom Doppler, avaliação do Índice Tornozelo-Braquial, Inventário breve de dor e escala de dor analógica foram realizados no início e após 30 dias. Houve redução da dor nos grupos Terapia a Laser de Baixa Intensidade e Terapia a Laser de Baixa intensidade associada aos Ácidos Graxos Essenciais, com pgrupos mantiveram-se estáveis. Na análise da redução de área da lesão, o grupo Terapia a Laser de Baixa Intensidade associada aos Ácidos Graxos Essenciais apresentou uma significância p=0,0032, e o grupo Terapia a Laser de Baixa Intensidade, p=0,0428. A Terapia a Laser de Baixa Intensidade, realizada tanto isoladamente quanto associada ao óleo de Calendula officinalis, foi eficaz no alívio da dor e na aceleração do processo de reparo tecidual de pé diabético.

  9. Molecular Iodine Fluorescence Using a Green Helium-Neon Laser

    Science.gov (United States)

    Williamson, J. Charles

    2011-01-01

    Excitation of molecular iodine vapor with a green (543.4 nm) helium-neon laser produces a fluorescence spectrum that is well suited for the upper-level undergraduate physical chemistry laboratory. Application of standard evaluation techniques to the spectrum yields ground electronic-state molecular parameters in good agreement with literature…

  10. Effect of low-level laser therapy on tissue repair after dental extraction in rats administered zoledronic acid and dexamethasone

    Science.gov (United States)

    Weber, João Batista Blessmann; Camilotti, Renata Stifelman; Jasper, Juliana; Casagrande, Liliane Cristina Onofre; Maito, Fábio Luiz Dal Moro

    2017-05-01

    Bisphosphonates (BPs) are being increasingly used for the treatment of metabolic and oncological pathologies involving the skeletal system. Because of the severity of the BP associated osteonecrosis of the jaws, the difficulties of treatment, and patient discomfort, additional support methods for their management are needed. Laser therapy has an easy handling, photobiostimulator effect on tissues healing, so it can be considered a preferred therapy. The aim of this study was to evaluate the influence of low-level laser therapy in the 685- and 830-nm wavelength in the healing process of the bone and soft tissues in rats under BP therapy [zoledronic acid (ZA)] and dexamethasone concomitantly that underwent a surgery for the extraction of upper molars. There were statistically significant differences in the clinical evaluation of the wound and the weight of the animals. Regarding the histological evaluation, it was possible to observe the different maturations of the healing stage between groups. The effect of drug therapy with ZA and dexamethasone in the bone tissue repair process induces osteonecrosis of the jaw in rats and slows down the healing process. In the laser groups, at the stipulated dosimetry, a positive influence on the bone and soft tissue repair process was observed.

  11. Enhanced vbasis laser diode package

    Science.gov (United States)

    Deri, Robert J.; Chen, Diana; Bayramian, Andy; Freitas, Barry; Kotovsky, Jack

    2014-08-19

    A substrate having an upper surface and a lower surface is provided. The substrate includes a plurality of v-grooves formed in the upper surface. Each v-groove includes a first side and a second side perpendicular to the first side. A laser diode bar assembly is disposed within each of the v-grooves and attached to the first side. The laser diode bar assembly includes a first adhesion layer disposed on the first side of the v-groove, a metal plate attached to the first adhesion layer, a second adhesion layer disposed over the metal plate, and a laser diode bar attached to the second adhesion layer. The laser diode bar has a coefficient of thermal expansion (CTE) substantially similar to that of the metal plate.

  12. Multiweek Cell Culture Project for Use in Upper-Level Biology Laboratories

    Science.gov (United States)

    Marion, Rebecca E.; Gardner, Grant E.; Parks, Lisa D.

    2012-01-01

    This article describes a laboratory protocol for a multiweek project piloted in a new upper-level biology laboratory (BIO 426) using cell culture techniques. Human embryonic kidney-293 cells were used, and several culture media and supplements were identified for students to design their own experiments. Treatments included amino acids, EGF,…

  13. A Laser-Induced Fluorescence Instrument for Aircraft Measurements of Sulfur Dioxide in the Upper Troposphere and Lower Stratosphere

    Science.gov (United States)

    Rollins, Andrew W.; Thornberry, Troy D.; Ciciora, Steven J.; McLaughlin, Richard J.; Watts, Laurel A.; Hanisco, Thomas F.; Baumann, Esther; Giorgetta, Fabrizio R.; Bui, Thaopaul V.; Fahey, David W.

    2016-01-01

    This work describes the development and testing of a new instrument for in situ measurements of sulfur dioxide (SO2) on airborne platforms in the upper troposphere and lower stratosphere (UTLS). The instrument is based on the laser-induced fluorescence technique and uses the fifth harmonic of a tunable fiber-amplified semiconductor diode laser system at 1084.5 nm to excite SO2 at 216.9 nm. Sensitivity and background checks are achieved in flight by additions of SO2 calibration gas and zero air, respectively. Aircraft demonstration was performed during the NASA Volcano Plume Investigation Readiness and Gas-Phase and Aerosol Sulfur (VIRGAS) experiment, which was a series of flights using the NASA WB-57F during October 2015 based at Ellington Field and Harlingen, Texas. During these flights, the instrument successfully measured SO2 in the UTLS at background (non-volcanic) conditions with a precision of 2 ppt at 10 s and an overall uncertainty determined primarily by instrument drifts of +/- (16% + 0.9 ppt).

  14. A low-level diode laser therapy reduces the lipopolysaccharide (LPS)-induced periodontal ligament cell inflammation

    International Nuclear Information System (INIS)

    Huang, T H; Chen, C C; Liu, S L; Lu, Y C; Kao, C T

    2014-01-01

    The purpose of this study was to investigate the cytologic effects of inflammatory periodontal ligament cells in vitro after low-level laser therapy. Human periodontal ligament cells were cultured, exposed to lipopolysaccharide and subjected to low-level laser treatment of 5 J cm −2 or 10 J cm −2 using a 920 nm diode laser. A periodontal ligament cell attachment was observed under a microscope, and the cell viability was quantified by a mitochondrial colorimetric assay. Lipopolysaccharide-treated periodontal ligament cells were irradiated with the low-level laser, and the expression levels of several inflammatory markers, iNOS, TNF-α and IL-1, and pErk kinase, were analyzed by reverse transcription polymerase chain reaction and western blot. The data were collected and analyzed by one-way analysis of variance; p < 0.05 indicated a statistically significant difference. The low-level laser treatment of periodontal ligament cells increased their ability to attach and survive. After irradiation, the expression levels of iNOS, TNF-α and IL-1 in lipopolysaccharide-exposed periodontal ligament cells decreased over time (p < 0.05). In periodontal ligament cells, low-level diode laser treatment increased the cells’ proliferative ability and decreased the expression of the examined inflammatory mediators. (letters)

  15. Temporal Variability of Upper-level Winds at the Eastern Range, Western Range and Wallops Flight Facility

    Science.gov (United States)

    Decker, Ryan; Barbre, Robert E.

    2014-01-01

    Space launch vehicles incorporate upper-level wind profiles to determine wind effects on the vehicle and for a commit to launch decision. These assessments incorporate wind profiles measured hours prior to launch and may not represent the actual wind the vehicle will fly through. Uncertainty in the upper-level winds over the time period between the assessment and launch can be mitigated by a statistical analysis of wind change over time periods of interest using historical data from the launch range. Five sets of temporal wind pairs at various times (.75, 1.5, 2, 3 and 4-hrs) at the Eastern Range, Western Range and Wallops Flight Facility were developed for use in upper-level wind assessments. Database development procedures as well as statistical analysis of temporal wind variability at each launch range will be presented.

  16. Upper Limb Muscle and Brain Activity in Light Assembly Task on Different Load Levels

    Science.gov (United States)

    Zadry, Hilma Raimona; Dawal, Siti Zawiah Md.; Taha, Zahari

    2010-10-01

    A study was conducted to investigate the effect of load on upper limb muscles and brain activities in light assembly task. The task was conducted at two levels of load (Low and high). Surface electromyography (EMG) was used to measure upper limb muscle activities of twenty subjects. Electroencephalography (EEG) was simultaneously recorded with EMG to record brain activities from Fz, Pz, O1 and O2 channels. The EMG Mean Power Frequency (MPF) of the right brachioradialis and the left upper trapezius activities were higher on the high-load task compared to low-load task. The EMG MPF values also decrease as time increases, that reflects muscle fatigue. Mean power of the EEG alpha bands for the Fz-Pz channels were found to be higher on the high-load task compared to low-load task, while for the O1-O2 channels, they were higher on the low-load task than on the high-load task. These results indicated that the load levels effect the upper limb muscle and brain activities. The high-load task will increase muscle activities on the right brachioradialis and the left upper tapezius muscles, and will increase the awareness and motivation of the subjects. Whilst the low-load task can generate drowsiness earlier. It signified that the longer the time and the more heavy of the task, the subjects will be more fatigue physically and mentally.

  17. Efficient energy extraction from a diode-pumped Q-switched Tm,Ho:YLiF4 laser

    Science.gov (United States)

    Mcguckin, B. T.; Menzies, R. T.; Hemmati, H.

    1991-01-01

    The operation of a diode-laser pumped thulium, holmium yttrium-lithium-fluoride laser (Tm,Ho:YLF) in Q-switched mode is reported. Output energies of 200 microjoules in pulses of 22 ns duration are recorded at Q-switch frequencies commensurate with an effective upper laser level lifetime of 6 ms. This lifetime is appreciably longer than that observed in other hosts permitting stored energy extraction of 64 percent, close to the projected maximum performance from these materials.

  18. The effects of low-level laser on muscle damage caused by Bothrops neuwiedi venom

    Directory of Open Access Journals (Sweden)

    DM Dourado

    2008-01-01

    Full Text Available The present study aimed to assess the effects of low-level laser (660 nm on myonecrosis caused by the insertion of Bothrops neuwiedi venom in the gastrocnemius muscle of rats. Male Wistar rats were divided into three groups (n = 24 each: Group S (0.9% saline solution; Group V (venom and Group VLLL (venom plus low-level laser. These categories were subdivided into four additional groups (n = 6 based on the euthanasia timing (3 hours, 24 hours, 3 days and 7 days. The groups V and VLLL were inoculated with 100 µL of concentrated venom (40 µg/mL in the gastrocnemius muscle. The muscle was irradiated using a gallium-aluminum-arsenide laser (GaAlAs at 35 mW power and 4 J/cm² energy density for 3 hours, 24 hours, 3 days or 7 days after venom inoculation. To evaluate the myotoxic activity of the venom, CK activity was measured and the muscle was histologically analyzed. The low-level laser reduced venom-induced CK activity in the groups euthanized at 3 hours, 24 hours and 3 days (p < 0.0001. Histological analysis revealed that low-level laser reduced neutrophilic inflammation as well as myofibrillar edema, hemorrhage and myonecrosis following B. neuwiedi envenomation. These results suggest that low-level laser can be useful as an adjunct therapy following B. neuwiedi envenomation.

  19. The effects of low-level laser on muscle damage caused by Bothrops neuwiedi venom

    Energy Technology Data Exchange (ETDEWEB)

    Dourado, D.M.; Matias, R.; Almeida, M.F.; Paula, K.R. de; Carvalho, P.T.C. [University for the Development of the State and of the Region of Pantanal (UNIDERP), Campo Grande, MS (Brazil). Lab. of Experimental Histopathology]. E-mail: ccfi@uniderp.br; Vieira, R.P. [University of Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Pathology and Physical Therapy; Oliveira, L.V.F. [Nove de Julho University (UNINOVE), Sao Paulo, SP (Brazil). Masters Program in Rehabilitation Sciences

    2008-07-01

    The present study aimed to assess the effects of low-level laser (660 nm) on myonecrosis caused by the insertion of Bothrops neuwiedi venom in the gastrocnemius muscle of rats. Male Wistar rats were divided into three groups (n = 24 each): Group S (0.9% saline solution); Group V (venom) and Group VLLL (venom plus low-level laser). These categories were subdivided into four additional groups (n = 6) based on the euthanasia timing (3 hours, 24 hours, 3 days and 7 days). The groups V and VLLL were inoculated with 100 {mu}L of concentrated venom (40 {mu}g/mL) in the gastrocnemius muscle. The muscle was irradiated using a gallium-aluminum-arsenide laser (GaAlAs) at 35 mW power and 4 J/cm{sup 2} energy density for 3 hours, 24 hours, 3 days or 7 days after venom inoculation. To evaluate the myotoxic activity of the venom, CK activity was measured and the muscle was histologically analyzed. The low-level laser reduced venom-induced CK activity in the groups euthanized at 3 hours, 24 hours and 3 days (p < 0.0001). Histological analysis revealed that low-level laser reduced neutrophilic inflammation as well as myofibrillar edema, hemorrhage and myonecrosis following B. neuwiedi envenomation. These results suggest that low-level laser can be useful as an adjunct therapy following B. neuwiedi envenomation. (author)

  20. The effects of low-level laser on muscle damage caused by Bothrops neuwiedi venom

    International Nuclear Information System (INIS)

    Dourado, D.M.; Matias, R.; Almeida, M.F.; Paula, K.R. de; Carvalho, P.T.C.; Vieira, R.P.; Oliveira, L.V.F.

    2008-01-01

    The present study aimed to assess the effects of low-level laser (660 nm) on myonecrosis caused by the insertion of Bothrops neuwiedi venom in the gastrocnemius muscle of rats. Male Wistar rats were divided into three groups (n = 24 each): Group S (0.9% saline solution); Group V (venom) and Group VLLL (venom plus low-level laser). These categories were subdivided into four additional groups (n = 6) based on the euthanasia timing (3 hours, 24 hours, 3 days and 7 days). The groups V and VLLL were inoculated with 100 μL of concentrated venom (40 μg/mL) in the gastrocnemius muscle. The muscle was irradiated using a gallium-aluminum-arsenide laser (GaAlAs) at 35 mW power and 4 J/cm 2 energy density for 3 hours, 24 hours, 3 days or 7 days after venom inoculation. To evaluate the myotoxic activity of the venom, CK activity was measured and the muscle was histologically analyzed. The low-level laser reduced venom-induced CK activity in the groups euthanized at 3 hours, 24 hours and 3 days (p < 0.0001). Histological analysis revealed that low-level laser reduced neutrophilic inflammation as well as myofibrillar edema, hemorrhage and myonecrosis following B. neuwiedi envenomation. These results suggest that low-level laser can be useful as an adjunct therapy following B. neuwiedi envenomation. (author)

  1. Laser in urology. Laser i urologien

    Energy Technology Data Exchange (ETDEWEB)

    Breisland, H.O. (Aker Sykehus, Oslo (Norway))

    1991-09-01

    The neodymium YAG laser is particularly suited for endoscopic urologic surgery because the YAG laser light can be conducted in flexible fibers. Superficial bladder tumours can be treated under local anaesthesia in the outpatient department. The frequency of local recurrences is low, significantly lower than after electrosection or electrocoagulation. Selected cases of T2-muscle invasive bladder tumours can be cured with laser coagulation applied subsequently to transurethral resection. Combined treatment with electrosection and laser coagulation of localized prostatic cancer is a promising method which compares favourably with results obtained by other treatment modalities. Tumours in the upper urinary tract can be laser-treated through ureteroscopes or nephroscopes, but the treatment should be limited to low stage, low grade tumours. Laser is the treatment of choice for intraurethral condylomatas. Laser treatment of penil carcinoma gives excellent cosmetic and functional results and few local recurrences. Laser lithotripsy is a new technique for treatment of ureteric stones and photodynamic laser therapy is a promising tecnique for treatment of carcinoma in situ in the bladder empithelium. However, neither of these techniques are available for clinical use in Norway as yet. 17 refs., 3 figs., 1 tabs.

  2. Low-level laser therapy for pain relief after episiotomy: a double-blind randomised clinical trial.

    Science.gov (United States)

    Santos, Jaqueline de O; de Oliveira, Sonia M J V; da Silva, Flora M B; Nobre, Moacyr R C; Osava, Ruth H; Riesco, Maria L G

    2012-12-01

    To evaluate the effectiveness of a low-level laser therapy for pain relief in the perineum following episiotomy during childbirth. Laser irradiation is a painless and non-invasive therapy for perineal pain treatment and its effects have been investigated in several studies, with no clear conclusion on its effectiveness. A double-blind randomised controlled clinical trial. One hundred and fourteen women who underwent right mediolateral episiotomies during vaginal birth in an in-hospital birthing centre in São Paulo, Brazil and reported pain ≥ 3 on a numeric scale (0-10) were randomised into three groups of 38 women each: two experimental groups (treated with red and infrared laser) and a control group. The experimental groups were treated with laser applied at three points directly on the episiotomy after suturing in a single session between 6-56 hours postpartum. We used a diode laser with wavelengths of 660 nm (red laser) and 780 nm (infrared laser). The control group participants underwent all laser procedures, excluding the emission of irradiation. The participants and the pain scores evaluator were blinded to the type of intervention. The perineal pain scores were assessed at three time points: before, immediately after and 30 minutes after low-level laser therapy. The comparison of perineal pain between the three groups showed no significant differences in the three evaluations (p = 0.445), indicating that the results obtained in the groups treated with low-level laser therapy were equivalent to the control group. Low-level laser therapy did not decrease the intensity of perineal pain reported by women who underwent right mediolateral episiotomy. The effect of laser in perineal pain relief was not demonstrated in this study. The dosage may not have been sufficient to provide relief from perineal pain after episiotomy during a vaginal birth. © 2012 Blackwell Publishing Ltd.

  3. Systematic review of low-level laser therapy for adult androgenic alopecia.

    Science.gov (United States)

    Delaney, Sean W; Zhang, Paul

    2017-12-29

    Alopecia is a common disorder affecting over half of the world's population. Within this condition, androgenic alopecia (AA) is the most common type, affecting 50% of males over 40 and 75% of females over 65. Anecdotal paradoxical hypertrichosis noted during laser epilation has generated interest in the possibility of using laser to stimulate hair growth. In this study, we aimed to critically appraise the application of low-level laser therapy for the treatment of AA in adults. A systematic review was performed on studies identified on Medline, EMBASE, Cochrane database, and clinicaltrials.org. Double-blinded randomized controlled trials were selected and analyzed quantitatively (meta-analysis) and qualitatively (quality of evidence, risk of bias). Low-level laser therapy appears to be a promising noninvasive treatment for AA in adults that is safe for self-administration in the home setting. Although shown to effectively stimulate hair growth when compared to sham devices, these results must be interpreted with caution. Further studies with larger samples, longer follow-up, and independent funding sources are necessary to determine the clinical effectiveness of this novel therapy.

  4. Estimation of amputation level with a laser Doppler flowmeter

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Jørgensen, J P; Vollmer-Larsen, B

    1989-01-01

    Leg amputation levels were decided in 24 patients suffering from atherosclerosis, using the conventional techniques of segmental blood pressure and radioisotope skin clearance. The skin microcirculation was measured and recorded before operation with a laser doppler flowmeter. A high correlation...... was found between the successful amputation levels and the maximal blood perfusion of the skin measured in this way....

  5. Low-level laser irradiation induces in vitro proliferation of mesenchymal stem cells

    International Nuclear Information System (INIS)

    Barboza, Carlos Augusto Galvão; Ginani, Fernanda; Soares, Diego Moura; Henriques, Águida Cristina Gomes; Freitas, Roseana de Almeida

    2014-01-01

    To evaluate the effect of low-level laser irradiation on the proliferation and possible nuclear morphological changes of mouse mesenchymal stem cells. Mesenchymal stem cells derived from bone marrow and adipose tissue were submitted to two applications (T0 and T48 hours) of low-level laser irradiation (660nm; doses of 0.5 and 1.0J/cm"2). The trypan blue assay was used to evaluate cell viability, and growth curves were used to analyze proliferation at zero, 24, 48, and 72 hours. Nuclear alterations were evaluated by staining with DAPI (4'-6-diamidino-2-phenylindole) at 72 hours. Bone marrow-derived mesenchymal stem cells responded to laser therapy in a dose-dependent manner. Higher cell growth was observed when the cells were irradiated with a dose of 1.0J/cm"2, especially after 24 hours (p<0.01). Adipose-derived mesenchymal stem cells responded better to a dose of 1.0J/cm"2, but higher cell proliferation was observed after 48 hours (p<0.05) and 72 hours (p<0.01). Neither nuclear alterations nor a significant change in cell viability was detected in the studied groups. Low-level laser irradiation stimulated the proliferation of mouse mesenchymal stem cells without causing nuclear alterations. The biostimulation of mesenchymal stem cells using laser therapy might be an important tool for regenerative therapy and tissue engineering

  6. Treatment of burning mouth syndrome with a low-level energy diode laser.

    Science.gov (United States)

    Yang, Hui-Wen; Huang, Yu-Feng

    2011-02-01

    To test the therapeutic efficacy of low-level energy diode laser on burning mouth syndrome. Burning mouth syndrome is characterized by burning and painful sensations in the mouth, especially the tongue, in the absence of significant mucosal abnormalities. Although burning mouth syndrome is relatively common, little is known regarding its etiology and pathophysiology. As a result, no treatment is effective in all patients. Low-level energy diode laser therapy has been used in a variety of chronic and acute pain conditions, including neck, back and myofascial pain, degenerative osteoarthritis, and headache. A total of 17 patients who had been diagnosed with burning mouth syndrome were treated with an 800-nm wavelength diode laser. A straight handpiece was used with an end of 1-cm diameter with the fiber end standing 4 cm away from the end of handpiece. When the laser was applied, the handpiece directly contacted or was immediately above the symptomatic lingual surface. The output used was 3 W, 50 msec intermittent pulsing, and a frequency of 10 Hz, which was equivalent to an average power of 1.5 W/cm(2) (3 W × 0.05 msec × 10 Hz = 1.5 W/cm(2)). Depending on the involved area, laser was applied to a 1-cm(2) area for 70 sec until all involved area was covered. Overall pain and discomfort were analyzed with a 10-cm visual analogue scale. All patients received diode laser therapy between one and seven times. The average pain score before the treatment was 6.7 (ranging from 2.9 to 9.8). The results showed an average reduction in pain of 47.6% (ranging from 9.3% to 91.8%). The burning sensation remained unchanged for up to 12 months. Low-level energy diode laser may be an effective treatment for burning mouth syndrome.

  7. Novel Approach to Treating Androgenetic Alopecia in Females With Photobiomodulation (Low-Level Laser Therapy).

    Science.gov (United States)

    Friedman, Shelly; Schnoor, Patricia

    2017-06-01

    Photobiomodulation, also referred to as low-level laser therapy (LLLT), has been studied and used for (among other diseases) the promotion of hair regrowth. A clinical study was developed to define the physiologic effects that occur when the human hair follicle and surrounding tissue structures are exposed to laser light using a novel device that is fitted with an array of laser diode sources operating at 650 nm and placed inside a sports cap to promote discretion while in use. The study demonstrates that low-level laser treatment of the scalp every other day for 17 weeks using the HANDI-DOME LASER device is a safe and effective treatment for androgenetic alopecia in healthy females between the ages of 18 to 60 with Fitzpatrick skin Types I to IV and Ludwig-Savin Baldness Scale I-2 to II-2 baldness patterns. Subjects receiving LLLT at 650 nm achieved a 51% increase in hair counts as compared with sham-treated control patients in this multicenter randomized controlled trial. These results suggest that the emerging technology of low-level laser therapy may play a potentially significant role in health care providers' armamentarium for the disease androgenic alopecia.

  8. Laser excitation of the n=3 level of positronium for antihydrogen production

    CERN Document Server

    Aghion, S; Ariga, A; Ariga, T; Bonomi, G; Braunig, P; Bremer, J; Brusa, R S; Cabaret, L; Caccia, M; Caravita, R; Castelli, F; Cerchiari, G; Chlouba, K; Cialdi, S; Comparat, D; Consolati, G; Demetrio, A; Di Noto, L; Doser, M; Dudarev, A; Ereditato, A; Evans, C; Ferragut, R; Fesel, J; Fontana, A; Forslund, O K; Gerber, S; Giammarchi, M; Gligorova, A; Gninenko, S N; Guatieri, F; Haider, S; Holmestad, H; Huse, T; Jernelv, I L; Jordan, E; Kellerbauer, A; Kimura, M; Koetting, T; Krasnicky, D; Lagomarsino, V; Lansonneur, P; Lebrun, P; Lehner, S; Liberadzka, J; Malbrunot, C; Mariazzi, S; Marx, L; Matveev, V A; Mazzotta, Z; Nebbia, G; Nedelec, P; Oberthaler, M K; Pacifico, N; Pagano, D; Penasa, L; Petracek, V; Pistillo, C; Prelz, F; Prevedelli, M; Ravelli, L; Resch, L; Rienacker, B; Røhne, O M; Rotondi, A; Sacerdoti, M; Sandaker, H; Santoro, R; Scampoli, P; Smestad, L; Sorrentino, F; Spacek, M; Storey, J; Strojek, I M; Testera, G; Tietje, I; Vamosi, S; Widmann, E; Yzombard, P; Zmeskal, J; Zurlo, N.

    2016-01-01

    We demonstrate laser excitation of the n=3 state of positronium (Ps) in vacuum. A specially designed high-efficiency pulsed slow positron beam and single shot positronium annihilation lifetime spectroscopy were used to produce and detect Ps. Pulsed laser excitation of n=3 level at 205 nm was monitored via Ps photoionization induced by a second intense laser pulse at 1064 nm. About 15% of the overall positronium emitted in vacuum was excited to n=3 and photoionized. Saturation of both the n=3 excitation and the following photoionization was observed and is explained by a simple rate equation model. Scanning the laser frequency allowed us to extract the positronium transverse temperature related to the width of the Doppler-broadened line. Moreover, preliminary observation of excitation to Rydberg states (n = 15...17) using n=3 as intermediate level was observed, giving an independent confirmation of efficient excitation to the 33P state.

  9. Low-level laser/light therapy for androgenetic alopecia.

    Science.gov (United States)

    Gupta, Aditya K; Lyons, Danika C A; Abramovits, William

    2014-01-01

    Androgenetic alopecia (AGA) is a persistent and pervasive condition that affects men worldwide. Some common treatment options for AGA include hair prosthetics, oral and topical medications, and surgical hair restoration (SHR). Pharmaceutical and SHR treatments are associated with limitations including adverse side effects and significant financial burden. Low-level laser or light (LLL) devices offer alternative treatment options that are not typically associated with adverse side effects or significant costs. There are clinic- and home-based LLL devices. One home-based laser comb device has set a standard for others; however, this device requires time devoted to carefully moving the comb through the hair to allow laser penetration to the scalp. A novel helmet-like LLL device for hair growth has proven effective in preliminary trials and allows for hands-free use. Regardless, there are few clinical trials that have been conducted regarding LLL devices for AGA and results are mixed. Further research is required to establish the true efficacy of these devices for hair growth in comparison to existing alternative therapies.

  10. The photo biological effect of low level laser therapy on serum level of leptin, cholesterol and triglycerides in overweight and obese females

    International Nuclear Information System (INIS)

    Salem, E.S.; Tawfik, M.S.; Youssef, S.S.; Serry, Z.M.; Aboel magd, H.F.

    2013-01-01

    The use of low level laser for body contouring and weight reduction depends on the photochemical non thermal effect of laser light on the adipose tissue. LLLT was reported to liquefy or release stored fat in adipocytes by the opening of specialized yet not identified cell membrane-associated pores after a brief treatment The concentration of leptin in adipose tissue and serum closely parallel the mass of adipose tissue and adipocyte size and triglycerides content. Thus, leptin increases in obesity and falls with weight loss. The current study was conducted to evaluate the effect of the low level laser therapy (LLLT) on leptin hormone, Cholesterol and triglyceride in both overweight and obese females. Twenty women were included in this study. Their ages ranged from 30-40 years. They were divided into two equal groups. Group A (Overweight group): included 10 females with BMI between 25 and 29.9 Kg/m2 -Group B (Obese group): included 10 females with BMI . 30. Both groups received LLL to the abdomen using laser scanner for uniform distribution of the beam above and below the umbilicus. Duration of treatment was 30 minutes, 2 times per week for 8 weeks as a total period of treatment. Serum level of leptin was estimated by radioimmunoassay (RIA). As regards serum cholesterol and triglyceride they were determined by enzymatic colorimetric test. Biochemical assessments were done before and after treatment. Results of the present study showed that in the overweight group laser treatment resulted in highly significant reduction in leptin serum level accompanied by highly significant increase in serum triglycerides level. Meanwhile, the increase in cholesterol level was insignificant. As regards the obese group, alteration in serum leptin level caused by laser treatment was not significant. In this group the increase in triglycerides and cholesterol serum levels after treatment were highly significant

  11. New energy levels of atomic niobium (Nb I) discovered by laser-spectroscopic investigations

    Science.gov (United States)

    Kröger, S.; Windholz, L.; Başar, Gü.; Başar, Gö.

    2018-06-01

    We report the discovery of 9 previously unknown energy levels of the atomic niobium, all having even parity. Two levels have energies below 19,500 cm-1 and angular momentum J = 3/2, while the energies of the others are located between 39,700 and 43,420 cm-1. The levels were discovered by laser excitation of several unclassified spectral lines in the wavelength range between 554 nm and 650 nm and detection of laser-induced fluorescence with a monochromator.

  12. Low-level laser irradiation induces in vitro proliferation of mesenchymal stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Carlos Augusto Galvão; Ginani, Fernanda [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil); Soares, Diego Moura [Universidade Federal de Pernambuco, Recife, PE (Brazil); Henriques, Águida Cristina Gomes; Freitas, Roseana de Almeida [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil)

    2014-07-01

    To evaluate the effect of low-level laser irradiation on the proliferation and possible nuclear morphological changes of mouse mesenchymal stem cells. Mesenchymal stem cells derived from bone marrow and adipose tissue were submitted to two applications (T0 and T48 hours) of low-level laser irradiation (660nm; doses of 0.5 and 1.0J/cm{sup 2}). The trypan blue assay was used to evaluate cell viability, and growth curves were used to analyze proliferation at zero, 24, 48, and 72 hours. Nuclear alterations were evaluated by staining with DAPI (4'-6-diamidino-2-phenylindole) at 72 hours. Bone marrow-derived mesenchymal stem cells responded to laser therapy in a dose-dependent manner. Higher cell growth was observed when the cells were irradiated with a dose of 1.0J/cm{sup 2}, especially after 24 hours (p<0.01). Adipose-derived mesenchymal stem cells responded better to a dose of 1.0J/cm{sup 2}, but higher cell proliferation was observed after 48 hours (p<0.05) and 72 hours (p<0.01). Neither nuclear alterations nor a significant change in cell viability was detected in the studied groups. Low-level laser irradiation stimulated the proliferation of mouse mesenchymal stem cells without causing nuclear alterations. The biostimulation of mesenchymal stem cells using laser therapy might be an important tool for regenerative therapy and tissue engineering.

  13. Effectiveness of low level laser therapy for treating male infertility

    Science.gov (United States)

    Vladimirovich Moskvin, Sergey; Ivanovich Apolikhin, Oleg

    2018-01-01

    In half of the cases, the infertility of the couple is due to the disorder of the male fertility. The leading factors that cause male infertility are urogenital infections, disorders of the immune system, testicular and prostate pathology, as well as endocrine disorders. Low level laser therapy (LLLT) is a very effective physical therapy method, used in many areas of medicine, including obstetrics and gynaecology, andrology and urology; and it is recommended as an integral part of the complex treatment of infertility. The literature review showed that LLLT is beneficial in treating male infertility. Laser can significantly improve the survival, motility and speed of movement of spermatozoa. Laser therapy of patients with prostatitis and vesiculitis can eliminate infiltrative-exudative changes, improve reproductive and copulatory functions. Local illumination of red (635 nm) and infrared (904 nm) spectra should be combined with intravenous laser blood illumination (ILBI) of red (635 nm) and ultraviolet (UV) (365 nm) spectra. PMID:29806585

  14. Level of Agreement Between Forearm and Upper Arm Blood Pressure Measurements in Patients With Large Arm Circumference.

    Science.gov (United States)

    Watson, Sheri; Aguas, Marita; Colegrove, Pat; Foisy, Nancy; Jondahl, Bonnie; Anastas, Zoe

    2017-02-01

    The purpose of the study was to determine if forearm blood pressures (BPs) measured in three different locations agree with the recommended upper arm location for noninvasive BP measurement. A method-comparison design was used. In a convenience sample of postanesthesia care unit patients with large upper arm circumference, BP's were obtained in three different forearm locations (lower forearm, middle forearm, and upper forearm) and compared to upper arm BP using an automated BP measuring device. The level of agreement (bias ± precision) between each forearm location and the upper arm BP was calculated using standard formulas. Acceptable levels of agreement based on expert opinion were set a priori at bias and precision values of less than ±5 mm Hg (bias) and ±8 mm Hg (precision). Forty-eight postanesthesia patients participated in the study. Bias and precision values were found to exceed the acceptable level of agreement for all but one of the systolic and diastolic BP comparisons in the three forearm BP locations. Fifty-six percent of all patients studied had one or more BP difference of at least 10 mm Hg in each of the three forearm locations, with 10% having one or more differences of at least 20 mm Hg. The differences in forearm BP measurements observed in this study indicate that the clinical practice of using a forearm BP with a regular-sized BP cuff in place of a larger sized BP cuff placed on the upper arm in postanesthesia care unit patients with large arm circumferences is inappropriate. The BPs obtained at the forearm location are not equivalent to the BPs obtained at the upper arm location. Copyright © 2015 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  15. Southern Dobrogea coastal potable water sources and Upper Quaternary Black Sea level changes

    Science.gov (United States)

    Caraivan, Glicherie; Stefanescu, Diana

    2013-04-01

    Southern Dobrogea is a typical geologic platform unit, placed in the south-eastern part of Romania, with a Pre-Cambrian crystalline basement and a Paleozoic - Quaternary sedimentary cover. It is bordered to the north by the Capidava - Ovidiu fault and by the Black Sea to the east. A regional WNW - ESE and NNE - SSW fault system divides the Southern Dobrogea structure in several tectonic blocks. Four drinking water sources have been identified: surface water, phreatic water, medium depth Sarmatian aquifer, and deep Upper Jurassic - Lower Cretaceous aquifer. Surface water sources are represented by several springs emerged from the base of the loess cliff, and a few small rivers, barred by coastal beaches. The phreatic aquifer develops at the base of the loess deposits, on the impervious red clay, overlapping the Sarmatian limestones. The medium depth aquifer is located in the altered and karstified Sarmatian limestones, and discharges into the Black Sea. The Sarmatian aquifer is unconfined where covered by silty loess deposits, and locally confined, where capped by clayey loess deposits. The aquifer is supplied from the Pre-Balkan Plateau. The Deep Upper Jurassic - Lower Cretaceous aquifer, located in the limestone and dolomite deposits, is generally confined and affected by the regional WNW - ESE and NNE - SSW fault system. In the south-eastern Dobrogea, the deep aquifer complex is separated from the Sarmatian aquifer by a Senonian aquitard (chalk and marls). The natural boundary of the Upper Jurassic - Lower Cretaceous aquifer is the Capidava - Ovidiu Fault. The piezometric heads show that the Upper Jurassic - Lower Cretaceous aquifer is supplied from the Bulgarian territory, where the Upper Jurassic deposits crop out. The aquifer discharges into the Black Sea to the east and into Lake Siutghiol to the northeast. The cyclic Upper Quaternary climate changes induced drastic remodeling of the Black Sea level and the corresponding shorelines. During the Last Glacial

  16. Low-level lasers affect uncoupling protein gene expression in skin and skeletal muscle tissues

    International Nuclear Information System (INIS)

    Canuto, K S; Sergio, L P S; Mencalha, A L; Fonseca, A S; Paoli, F

    2016-01-01

    Wavelength, frequency, power, fluence, and emission mode determine the photophysical, photochemical, and photobiological responses of biological tissues to low-level lasers. Free radicals are involved in these responses acting as second messengers in intracellular signaling processes. Irradiated cells present defenses against these chemical species to avoid unwanted effects, such as uncoupling proteins (UCPs), which are part of protective mechanisms and minimize the effects of free radical generation in mitochondria. In this work UCP2 and UCP3 mRNA gene relative expression in the skin and skeletal muscle tissues of Wistar rats exposed to low-level red and infrared lasers was evaluated. Samples of the skin and skeletal muscle tissue of Wistar rats exposed to low-level red and infrared lasers were withdrawn for total RNA extraction, cDNA synthesis, and the evaluation of gene expression by quantitative polymerase chain reaction. UCP2 and UCP3 mRNA expression was differently altered in skin and skeletal muscle tissues exposed to lasers in a wavelength-dependent effect, with the UCP3 mRNA expression dose-dependent. Alteration on UCP gene expression could be part of the biostimulation effect and is necessary to make cells exposed to red and infrared low-level lasers more resistant or capable of adapting in damaged tissues or diseases. (paper)

  17. Incentivizing Advanced Mathematics Study at Upper Secondary Level: The Case of Bonus Points in Ireland

    Science.gov (United States)

    Treacy, Páraic Thomas

    2018-01-01

    Secondary level mathematics education in Ireland has recently experienced a period of significant change with the introduction of new curricula and the addition of an incentive to study upper secondary mathematics at the most advanced level (Higher Level). This incentive, typically referred to as 'bonus points', appears to have aided a significant…

  18. Efficacy of low-level laser therapy on orofacial pain: A literature review

    Directory of Open Access Journals (Sweden)

    Haleh Zokaee

    2018-01-01

    Full Text Available Low-level laser therapy (LLLT is a therapeutic approach to treat orofacial pain using a 600–1000 nm laser with a <500 mW power. The efficacy of LLLT is due to the chemical reactions causing an anti-inflammatory and analgesic effect on the affected regions. The aim of this study is to review the effects of low-level laser application on orofacial pain in the English articles released since 2017. Our search keywords were 'low-level laser therapy, temporomandibular disease (TMD, mucositis and orofacial pain'. The most relevant papers were clinical trial, review and meta-analysis articles. 26 out of 243 searched articles were selected from PubMed, Google Scholar and Science Direct and reviewed. Most of the studies reported the positive role of LLLT on orofacial pain relief regardless of their variable procedures; however, the exact mechanism of action still remains unclear. Some studies indicated that LLLT has significantly reduced pain, reduceamount of clicking and both masseter and temporal muscles activityin TMD. As an overall result, it is concluded that LLLT can be served as a therapeutic method for myofascial pain, mucositis and temporomandibular joint disorders and this is due to its analgesic features.

  19. The effect of a coupling field on the entanglement dynamics of a three-level atom

    International Nuclear Information System (INIS)

    Mortezapour, Ali; Mahmoudi, Mohammad; Abedi, Majid; Khajehpour, M R H

    2011-01-01

    The effect of a coupling laser field on the entanglement of a three-level quantum system and its spontaneous emission is investigated via the reduced quantum entropy. We consider two schemes: the upper- and lower-level couplings. By calculating the degree of entanglement (DEM) for both systems, it is shown that the entanglement between the atom and its spontaneous emission can be controlled by the coupling laser field. This field, however, affects the entanglement differently in the two schemes; it is only the lower-level coupling scheme that shows a non-zero steady state DEM which can be controlled by the intensity and detuning of the coupling laser field.

  20. The effect of a coupling field on the entanglement dynamics of a three-level atom

    Energy Technology Data Exchange (ETDEWEB)

    Mortezapour, Ali; Mahmoudi, Mohammad [Physics Department, Zanjan University, PO Box 45195-313, Zanjan (Iran, Islamic Republic of); Abedi, Majid; Khajehpour, M R H, E-mail: mahmoudi@iasbs.ac.ir, E-mail: pour@iasbs.ac.ir [Institute for Advanced Studies in Basic Sciences, PO Box 45195-159, Zanjan (Iran, Islamic Republic of)

    2011-04-28

    The effect of a coupling laser field on the entanglement of a three-level quantum system and its spontaneous emission is investigated via the reduced quantum entropy. We consider two schemes: the upper- and lower-level couplings. By calculating the degree of entanglement (DEM) for both systems, it is shown that the entanglement between the atom and its spontaneous emission can be controlled by the coupling laser field. This field, however, affects the entanglement differently in the two schemes; it is only the lower-level coupling scheme that shows a non-zero steady state DEM which can be controlled by the intensity and detuning of the coupling laser field.

  1. Long-lived CO/sub 2/ lasers with distributed heterogeneous catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Browne, P G; Smith, A L.S.

    1974-12-11

    In a sealed CO/sub 2/-N/sub 2/-He system with a clean discharge tube the degree of dissociation of the CO/sub 2/ is greater than 80 percent (with no hydrogen present), and laser action cannot be obtained. If Pt is distributed along the discharge tube walls as a discontinuous film it catalyses back-reactions reforming CO/sub 2/. The degree of dissociation is then less than 40 percent, and efficient laser action at 10.6 ..mu.. is obtained. Using such distributed heterogeneous catalysis, a CO/sub 2/-N/sub 2/-He-Xe laser has operated for more than 3000 h. In this system, both H/sub 2/ and D/sub 2/ are undesirable additives because they decrease the excitation rate of the upper laser level. (auth)

  2. Synoptic climatology of the long-distance dispersal of white pine blister rust I. Development of an upper level synoptic classification

    Science.gov (United States)

    K. L. Frank; L. S. Kalkstein; B. W. Geils; H. W. Thistle

    2008-01-01

    This study developed a methodology to temporally classify large scale, upper level atmospheric conditions over North America, utilizing a newly-developed upper level synoptic classification (ULSC). Four meteorological variables: geopotential height, specific humidity, and u- and v-wind components, at the 500 hPa level over North America were obtained from the NCEP/NCAR...

  3. Efficacy of Low Level Laser Therapy After Hand Flexor Tendon Repair

    Science.gov (United States)

    Ayad, K. E.; El Gohary, H. M.; Abd Elrahman, M.; Abd El Mejeed, S. F.; Bekheet, A. B.

    2009-09-01

    Flexor tendon injury is a common problem requiring suturing repair followed by early postoperative mobilization. Muscle atrophy, joint stiffness, osteoarthritis, infection, skin necrosis, ulceration of joint cartilage and tendocutaneous adhesion are familiar complications produced by prolonged immobilization of surgically repaired tendon ruptures. The purpose of this study was to clarify the importance of low level laser therapy after hand flexor tendon repair in zone II. Thirty patients aging between 20 and 40 years were divided into two groups. Patients in group A (n = 15) received a conventional therapeutic exercise program while patients in group B (n = 15) received low level laser therapy combined with the same therapeutic exercise program. The results showed a statistically significant increase in total active motion of the proximal and distal interphalangeal joints as well as maximum hand grip strength at three weeks and three months postoperative, but improvement was more significant in group B. It was concluded that the combination of low level laser therapy and early therapeutic exercises was more effective than therapeutic exercises alone in improving total active motion of proximal and distal interphalangeal joints and hand grip strength after hand flexor tendon repair.

  4. Colorado Upper-Division Electrostatics Diagnostic: A Conceptual Assessment for the Junior Level

    Science.gov (United States)

    Chasteen, Stephanie V.; Pepper, Rachel E.; Caballero, Marcos D.; Pollock, Steven J.; Perkins, Katherine K.

    2012-01-01

    As part of an effort to systematically improve our junior-level E&M I course, we have developed a tool to assess student conceptual learning of electrostatics at the upper division. Together with a group of physics faculty, we established a list of learning goals for the course that, with results from student observations and interviews,…

  5. Cell viability, reactive oxygen species, apoptosis, and necrosis in myoblast cultures exposed to low-level infrared laser.

    Science.gov (United States)

    Alexsandra da Silva Neto Trajano, Larissa; da Silva, Camila Luna; de Carvalho, Simone Nunes; Cortez, Erika; Mencalha, André Luiz; de Souza da Fonseca, Adenilson; Stumbo, Ana Carolina

    2016-07-01

    Low-level infrared laser is considered safe and effective for treatment of muscle injuries. However, the mechanism involved on beneficial effects of laser therapy are not understood. The aim was to evaluate cell viability, reactive oxygen species, apoptosis, and necrosis in myoblast cultures exposed to low-level infrared laser at therapeutic fluences. C2C12 myoblast cultures at different (2 and 10 %) fetal bovine serum (FBS) concentrations were exposed to low-level infrared laser (808 nm, 100 mW) at different fluences (10, 35, and 70 J/cm(2)) and evaluated after 24, 48, and 72 h. Cell viability was evaluated by WST-1 assay; reactive oxygen species (ROS), apoptosis, and necrosis were evaluated by flow cytometry. Cell viability was decreased atthe lowest FBS concentration. Laser exposure increased the cell viability in myoblast cultures at 2 % FBS after 48 and 72 h, but no significant increase in ROS was observed. Apoptosis was decreased at the higher fluence and necrosis was increased at lower fluence in myoblast cultures after 24 h of laser exposure at 2 % FBS. No laser-induced alterations were obtained at 10 % FBS. Results show that level of reactive oxygen species is not altered, at least to those evaluated in this study, but low-level infrared laser exposure affects cell viability, apoptosis, and necrosis in myoblast cultures depending on laser fluence and physiologic conditions of cells.

  6. TP53 and ATM mRNA expression in skin and skeletal muscle after low-level laser exposure.

    Science.gov (United States)

    Guedes de Almeida, Luciana; Sergio, Luiz Philippe da Silva; de Paoli, Flavia; Mencalha, Andre Luiz; da Fonseca, Adenilson de Souza

    2017-08-01

    Low-level lasers are widespread in regenerative medicine, but the molecular mechanisms involved in their biological effects are not fully understood, particularly those on DNA stability. Therefore, this study aimed to investigate mRNA expression of genes related to DNA genomic stability in skin and skeletal muscle tissue from Wistar rats exposed to low-level red and infrared lasers. For this, TP53 (Tumor Protein 53) and ATM (Ataxia Telangiectasia Mutated gene) mRNA expressions were evaluated by real-time quantitative PCR (RT-qPCR) technique 24 hours after low-level red and infrared laser exposure. Our data showed that relative TP53 mRNA expression was not significantly altered in both tissues exposed to lasers. For ATM, relative mRNA expression in skin tissue was not significantly altered, but in muscle tissue, laser exposure increased relative ATM mRNA expression. Low-level red and infrared laser radiations alter ATM mRNA expression related to DNA stability in skeletal muscle tissue.

  7. Continuous anti-Stokes Raman laser operation

    International Nuclear Information System (INIS)

    Feitisch, A.; Muller, T.; Welling, H.; Wellegehausen, B.

    1988-01-01

    The anti-Stokes Raman laser (ASRL) process has proved to be a method that works well for frequency upconversion and for the generation of powerful tunable narrowband (pulsed) laser radiation in the UV and VUV spectral range. This conversion process allows large-frequency shifts in single step, high output energies, and high efficiencies. A basic requirement is population inversion on a two-photon transition, where, in general, the upper level of the transition should be metastable. Up to now the ASRL technique has only been demonstrated for the pulsed regime, where the necessary population inversion was generated by photodissociation or inner shell photoionization. These inversion techniques, however, cannot be transferred to cw operation of an ASRL, and, therefore, other inversion techniques have to be developed. Here a novel approach for the creation of the necessary population inversion is proposed, that uses well-known cw gas lasers as the active material for the conversion process. The basic idea is to use either existing two-photon population inversions in a cw laser material or to generate the necessary population inversion by applying a suitable population transfer process to the material. A natural two-photon inversion situation in a laser material is evident whenever a cascade laser can be operated. Cascade laser-based anti-Stokes schemes are possible in a He-Ne laser discharge, and investigations of these schemes are discussed

  8. Effects of low-level laser therapy on wound healing

    Directory of Open Access Journals (Sweden)

    Fabiana do Socorro da Silva Dias Andrade

    Full Text Available OBJECTIVE: To gather and clarify the actual effects of low-level laser therapy on wound healing and its most effective ways of application in human and veterinary medicine.METHODS: We searched original articles published in journals between the years 2000 and 2011, in Spanish, English, French and Portuguese languages, belonging to the following databases: Lilacs, Medline, PubMed and Bireme; Tey should contain the methodological description of the experimental design and parameters used.RESULTS: doses ranging from 3 to 6 J/cm2 appear to be more effective and doses 10 above J/cm2 are associated with deleterious effects. The wavelengths ranging from 632.8 to 1000 nm remain as those that provide more satisfactory results in the wound healing process.CONCLUSION: Low-level laser can be safely applied to accelerate the resolution of cutaneous wounds, although this fact is closely related to the election of parameters such as dose, time of exposure and wavelength.

  9. Optimum design of a multi-stage dye-laser amplifier pumped with Cu-vapor lasers

    International Nuclear Information System (INIS)

    Maeda, Mitsuo; Uchiumi, Michihiro

    1990-01-01

    A numerical simulation code, based on the one-dimensional photon transport equation, was developed and analyzed to evaluate the performances of Rhodamine 6G dye laser amplifiers pumped with Cu-vapor lasers. The upper singlet-state absorption played an important role to determine the efficiency. The simulation code was applied to optimize a multi-stage amplifier system with a pulsed or a CW dye-laser oscillator. The analytical results gave a useful guideline to design a high-power pulsed dye-laser system for atomic uranium enrichment. (author)

  10. Examining portfolio-based assessment in an upper-level biology course

    Science.gov (United States)

    Ziegler, Brittany Ann

    Historically, students have been viewed as empty vessels and passive participants in the learning process but students actually are active forming their own conceptions. One way student learning is impacted is through assessment. Alternative assessment, which contrasts traditional assessment methods, takes into account how students learn by promoting engagement and construction of knowledge This dissertation explores portfolio-based assessment, a method of alternative assessment, which requires students to compose a purposeful collection of work demonstrating their knowledge in an upper-level biology course. The research objectives include characterizing and contributing to the understanding of portfolio-based assessment in higher education, examining reflection and inquiry portfolio components, determining student knowledge of biological concepts, and investigating student integrative thinking through the transformation of reflections into concept webs One main finding includes the majority of reflections categorized as naive or novice in quality. There was no difference in quality of reflections among biological topic. There was a relatively equal amount of high and low cognitive level questions. Students' knowledge of biological concepts significantly increased from the beginning to end of the course. Student written reflections were transformed into concept webs to allow for examination of student integrative thinking. Concepts, relationships, and interconnections in concept webs showed variation but declined by the end of the semester This study is one of the first examining portfolio-based assessment in an upper-level biology course We do not contend that this method of assessment is the only way to promote student learning but portfolio-based assessment may be a tool that can transform science education but currently the role of portfolio-based assessment in science education remains unclear. Additional research needs to be conducted before we will fully

  11. On the possibility of developing quasi-CW high-power high-pressure laser on 4p-4s transition of ArI with electron beam—optical pumping: quenching of 4s (3P2) lower laser level

    Science.gov (United States)

    Ionin, A. A.; Kholin, I. V.; L'dov, A. Yu; Seleznev, L. V.; Ustinovskii, N. N.; Zayarnyi, D. A.

    2017-12-01

    A new electron beam-optical procedure is proposed for quasi-cw pumping of high-pressure large-volume He-Ar laser on the 4p[1/2]1-4s[3/2]20 argon atom transition at the wavelength of 912.5 nm. It consists of creation and maintenance of a necessary density of the 4s[3/2]20 metastable state in the gain medium by a fast electron beam and subsequent optical pumping of the upper laser level via the classical three-level scheme using a laser diode. Absorption probing is used to study collisional quenching of Ar* metastable in electron-beam-excited high-pressure He-Ar mixtures with a low content of argon. The rate constants for plasma-chemical reactions Ar*  +  He  +  Ar  >  Ar2*   +  He (3.6  ±  0.4)  ×  10-33 cm6 s-1, Ar*  +  2He  >  HeAr*  +  He (4.4  ±  0.9)  ×  10-36 cm6 s-1 and Ar*  +  He  >  Products  +  He (2.4  ±  0.3)  ×  10-15 cm3 s-1 were for the first time measured.

  12. Effect of low-level pulsed laser 890-nm on lumbar spondylolisthesis: a case report

    Science.gov (United States)

    Mortazavi, Seyed M. J.; Afsharpad, Mitra; Djavid, Gholam-reza E.

    2002-10-01

    Objective: Evaluating the effectiveness of low-level laser therapy (LLLT) in alleviating the symptoms of lumbar spondylolisthesis. Materials and Methods: Laser was irradiated for 2 mm at six symmetric points along the lumbosacral spine and 5 points along the referred point ofpain, six times a week for 2 weeks (890 nm; 8 J/cm2; pulsed at 1500 Hz). Perception of benefit, level of function was assessed by the Oswestry disability index, lumbar mobility range of motion and low back pain intensity. Results and Discussion: Results showed a complete reduction in pain and improvement in function in the patient. This case report suggests that low-level laser therapy (LLLT) could play a role in conservative management of low-grade lumbar spondylolisthesis.

  13. Student Perceptions of an Upper-Level, Undergraduate Human Anatomy Laboratory Course without Cadavers

    Science.gov (United States)

    Wright, Shirley J.

    2012-01-01

    Several programs in health professional education require or are considering requiring upper-level human anatomy as prerequisite for their applicants. Undergraduate students are confronted with few institutions offering such a course, in part because of the expense and logistical issues associated with a cadaver-based human anatomy course. This…

  14. Therapeutic CPAP Level Predicts Upper Airway Collapsibility in Patients With Obstructive Sleep Apnea.

    Science.gov (United States)

    Landry, Shane A; Joosten, Simon A; Eckert, Danny J; Jordan, Amy S; Sands, Scott A; White, David P; Malhotra, Atul; Wellman, Andrew; Hamilton, Garun S; Edwards, Bradley A

    2017-06-01

    Upper airway collapsibility is a key determinant of obstructive sleep apnea (OSA) which can influence the efficacy of certain non-continuous positive airway pressure (CPAP) treatments for OSA. However, there is no simple way to measure this variable clinically. The present study aimed to develop a clinically implementable tool to evaluate the collapsibility of a patient's upper airway. Collapsibility, as characterized by the passive pharyngeal critical closing pressure (Pcrit), was measured in 46 patients with OSA. Associations were investigated between Pcrit and data extracted from patient history and routine polysomnography, including CPAP titration. Therapeutic CPAP level, demonstrated the strongest relationship to Pcrit (r2=0.51, p CPAP level (6.2 ± 0.6 vs. 10.3 ± 0.4 cmH2O, p -2 cmH2O). A therapeutic CPAP level ≤8.0 cmH2O was sensitive (89%) and specific (84%) for detecting a mildly collapsible upper airway. When applied to the independent validation data set (n = 74), this threshold maintained high specificity (91%) but reduced sensitivity (75%). Our data demonstrate that a patient's therapeutic CPAP requirement shares a strong predictive relationship with their Pcrit and may be used to accurately differentiate OSA patients with mild airway collapsibility from those with moderate-to-severe collapsibility. Although this relationship needs to be confirmed prospectively, our findings may provide clinicians with better understanding of an individual patient's OSA phenotype, which ultimately could assist in determining which patients are most likely to respond to non-CPAP therapies. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  15. High level compressive residual stresses produced in aluminum alloys by laser shock processing

    International Nuclear Information System (INIS)

    Gomez-Rosas, G.; Rubio-Gonzalez, C.; Ocana, J.L; Molpeceres, C.; Porro, J.A.; Chi-Moreno, W.; Morales, M.

    2005-01-01

    Laser shock processing (LSP) has been proposed as a competitive alternative technology to classical treatments for improving fatigue and wear resistance of metals. We present a configuration and results for metal surface treatments in underwater laser irradiation at 1064 nm. A convergent lens is used to deliver 1.2 J/cm 2 in a 8 ns laser FWHM pulse produced by 10 Hz Q-switched Nd:YAG, two laser spot diameters were used: 0.8 and 1.5 mm. Results using pulse densities of 2500 pulses/cm 2 in 6061-T6 aluminum samples and 5000 pulses/cm 2 in 2024 aluminum samples are presented. High level of compressive residual stresses are produced -1600 MPa for 6061-T6 Al alloy, and -1400 MPa for 2024 Al alloy. It has been shown that surface residual stress level is higher than that achieved by conventional shot peening and with greater depths. This method can be applied to surface treatment of final metal products

  16. An Instrument to Determine the Technological Literacy Levels of Upper Secondary School Students

    Science.gov (United States)

    Luckay, Melanie B.; Collier-Reed, Brandon I.

    2014-01-01

    In this article, an instrument for assessing upper secondary school students' levels of technological literacy is presented. The items making up the instrument emerged from a previous study that employed a phenomenographic research approach to explore students' conceptions of technology in terms of their understanding of the "nature…

  17. Hyperfine structure measurements and discovery of new energy levels in neutral praseodymium

    Energy Technology Data Exchange (ETDEWEB)

    Imran, Siddiqui; Khan, Shamim; Syed, Tanweer Iqbal; Gamper, Bettina; Windholz, Laurentius [Inst. f. Experimentalphysik, Techn. Univ. Graz, Petersgasse 16, A-8010 Graz (Austria)

    2011-07-01

    We present here 14 even and 17 odd parity new energy levels of the neutral praseodymium atom. Free praseodymium atoms in ground and excited states are produced in a hollow cathode discharge lamp by cathode sputtering. The hyperfine structure (hfs) of the spectral lines is investigated by the method of laser induced fluorescence (LIF) spectroscopy. As an example of the method used we discuss briefly the finding of the new level at 27304.431 cm{sup -1}, even parity, J=9/2 and A=690(1) MHz. Laser excitation of the line at 6004.23 Aa is performed and a LIF signal is detected at fluorescence lines 5246.709, 5412.95, 5925.10, 6107.88, 6287.02, 6419.16, and 6620.63 A. The hfs is then recorded digitally and fitted to find reliable values of angular momentum J, magnetic and electric quadrupole hyperfine constants A and B for the combining fine structure levels. Assuming an unknown upper level, a lower level is searched in the data base of known levels, having the J and A values determined from the fit procedure. A level with 10654.11 cm{sup -1}, odd parity, J=7/2 and A=169(2) MHz is found. The energy of the upper level is calculated by adding the center of gravity wave number of the excited line to the energy of the lower level. The existence of the new level is checked by at least one additional laser excitation from another known lower level.

  18. Mid infrared lasers for remote sensing applications

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Brian M., E-mail: brian.m.walsh@nasa.gov [NASA Langley Research Center, Hampton, VA 23681 (United States); Lee, Hyung R. [National Institute of Aerospace, Hampton, VA 23666 (United States); Barnes, Norman P. [Science Systems and Applications, Inc., Hampton, VA 23666 (United States)

    2016-01-15

    To accurately measure the concentrations of atmospheric gasses, especially the gasses with low concentrations, strong absorption features must be accessed. Each molecular species or constituent has characteristic mid-infrared absorption features by which either column content or range resolved concentrations can be measured. Because of these characteristic absorption features the mid infrared spectral region is known as the fingerprint region. However, as noted by the Decadal Survey, mid-infrared solid-state lasers needed for DIAL systems are not available. The primary reason is associated with short upper laser level lifetimes of mid infrared transitions. Energy gaps between the energy levels that produce mid-infrared laser transitions are small, promoting rapid nonradiative quenching. Nonradiative quenching is a multiphonon process, the more phonons needed, the smaller the effect. More low energy phonons are required to span an energy gap than high energy phonons. Thus, low energy phonon materials have less nonradiative quenching compared to high energy phonon materials. Common laser materials, such as oxides like YAG, are high phonon energy materials, while fluorides, chlorides and bromides are low phonon materials. Work at NASA Langley is focused on a systematic search for novel lanthanide-doped mid-infrared solid-state lasers using both quantum mechanical models (theoretical) and spectroscopy (experimental) techniques. Only the best candidates are chosen for laser studies. The capabilities of modeling materials, experimental challenges, material properties, spectroscopy, and prospects for lanthanide-doped mid-infrared solid-state laser devices will be presented. - Highlights: • We discuss mid infrared lasers and laser materials. • We discuss applications to remote sensing. • We survey the lanthanide ions in low phonon materials for potential. • We present examples of praseodymium mid infrared spectroscopy and laser design.

  19. Vandenberg Air Force Base Upper Level Wind Launch Weather Constraints

    Science.gov (United States)

    Shafer, Jaclyn A.; Wheeler, Mark M.

    2012-01-01

    The 30th Operational Support Squadron Weather Flight (30 OSSWF) provides comprehensive weather services to the space program at Vandenberg Air Force Base (VAFB) in California. One of their responsibilities is to monitor upper-level winds to ensure safe launch operations of the Minuteman III ballistic missile. The 30 OSSWF tasked the Applied Meteorology Unit (AMU) to analyze VAFB sounding data with the goal of determining the probability of violating (PoV) their upper-level thresholds for wind speed and shear constraints specific to this launch vehicle, and to develop a tool that will calculate the PoV of each constraint on the day of launch. In order to calculate the probability of exceeding each constraint, the AMU collected and analyzed historical data from VAFB. The historical sounding data were retrieved from the National Oceanic and Atmospheric Administration Earth System Research Laboratory archive for the years 1994-2011 and then stratified into four sub-seasons: January-March, April-June, July-September, and October-December. The maximum wind speed and 1000-ft shear values for each sounding in each subseason were determined. To accurately calculate the PoV, the AMU determined the theoretical distributions that best fit the maximum wind speed and maximum shear datasets. Ultimately it was discovered that the maximum wind speeds follow a Gaussian distribution while the maximum shear values follow a lognormal distribution. These results were applied when calculating the averages and standard deviations needed for the historical and real-time PoV calculations. In addition to the requirements outlined in the original task plan, the AMU also included forecast sounding data from the Rapid Refresh model. This information provides further insight for the launch weather officers (LWOs) when determining if a wind constraint violation will occur over the next few hours on day of launch. The interactive graphical user interface (GUI) for this project was developed in

  20. Pilot study in neonates using low-level laser therapy in the immediate postoperative period of myelomeningocele

    Directory of Open Access Journals (Sweden)

    Nathali Cordeiro Pinto

    2010-03-01

    Full Text Available Objective: To analyze the tissue repair behavior after corrective surgical incision in neonates submitted to low-level laser therapy, in an attempt to diminish the incidence of postoperative dehiscence following the surgery for myelomeningocele performed immediately after birth. Methods: It is a prospective pilot study with 13 myelomeningocele patients submitted to surgery at birth who received adjuvant treatment with low-level laser therapy (Group A. Diode laser C.W., λ = 685t nm, p = 21 mW, E = 0.19 J was punctually applied along the surgical incision, summing up 4 to 10 J energy delivered per patient, according to the surgical wound area and, then, compared with the previous results, which were obtained from 23 patients undergoing surgery without laser therapy (Group B. Results: This pilot study showed a significant decline in dehiscence of surgical wounds in neonates submitted to low-level laser therapy as compared to controls (7.69 versus 17.39%, respectively, demonstrating this is an effective, safe and noninvasive treatment method. Conclusion: This new adjuvant therapeutic proposal with low-level laser therapy aided healing of surgical wounds, preventing morbidities, as well as decreasing hospital stay, which implies cost of reduction for patients and for the institution.

  1. Component-Level Selection and Qualification for the Global Ecosystem Dynamics Investigation (GEDI) Laser Altimeter Transmitter

    Science.gov (United States)

    Frese, Erich A.; Chiragh, Furqan L.; Switzer, Robert; Vasilyev, Aleksey A.; Thomes, Joe; Coyle, D. Barry; Stysley, Paul R.

    2018-01-01

    Flight quality solid-state lasers require a unique and extensive set of testing and qualification processes, both at the system and component levels to insure the laser's promised performance. As important as the overall laser transmitter design is, the quality and performance of individual subassemblies, optics, and electro-optics dictate the final laser unit's quality. The Global Ecosystem Dynamics Investigation (GEDI) laser transmitters employ all the usual components typical for a diode-pumped, solid-state laser, yet must each go through their own individual process of specification, modeling, performance demonstration, inspection, and destructive testing. These qualification processes and results for the laser crystals, laser diode arrays, electro-optics, and optics, will be reviewed as well as the relevant critical issues encountered, prior to their installation in the GEDI flight laser units.

  2. Expression of DNA repair genes in burned skin exposed to low-level red laser.

    Science.gov (United States)

    Trajano, Eduardo Tavares Lima; Mencalha, Andre Luiz; Monte-Alto-Costa, Andréa; Pôrto, Luís Cristóvão; de Souza da Fonseca, Adenilson

    2014-11-01

    Although red laser lights lie in the region of non-ionizing radiations in the electromagnetic spectrum, there are doubts whether absorption of these radiations causes lesions in the DNA molecule. Our aim was to investigate the expression of the genes involved with base excision and nucleotide excision repair pathways in skin tissue submitted to burn injury and exposed to low-level red laser. Wistar rats were divided as follows: control group-rats burned and not irradiated, laser group-rats burned and irradiated 1 day after injury for five consecutive days, and later laser group-rats injured and treated 4 days after injury for five consecutive days. Irradiation was performed according to a clinical protocol (20 J/cm(2), 100 mW, continuous wave emission mode). The animals were sacrificed on day 10, and scarred tissue samples were withdrawn for total RNA extraction, complementary DNA (cDNA) synthesis, and evaluation of gene expression by quantitative polymerase chain reaction. Low-level red laser exposure (1) reduces the expression of APE1 messenger (mRNA), (2) increases the expression of OGG1 mRNA, (3) reduces the expression of XPC mRNA, and (4) increases the expression of XPA mRNA both in laser and later laser groups. Red laser exposure at therapeutic fluences alters the expression of genes related to base excision and nucleotide excision pathways of DNA repair during wound healing of burned skin.

  3. Thulium Laser Treatment of Upper Urinary Tract Carcinoma: A Multi-Institutional Analysis of Surgical and Oncological Outcomes.

    Science.gov (United States)

    Musi, Gennaro; Mistretta, Francesco A; Marenghi, Carlo; Russo, Andrea; Catellani, Michele; Nazzani, Sebastiano; Conti, Andrea; Luzzago, Stefano; Ferro, Matteo; Matei, Deliu V; Carmignani, Luca; de Cobelli, Ottavio

    2018-03-01

    To evaluate the efficacy and safety of ureteroscopic thulium laser (TL) treatment of upper urinary tract carcinoma (UTUC). Forty-two consecutive patients underwent conservative TL treatment for UTUC at two referral institutions. All patients underwent preliminary biopsy and then laser vaporization. A 272 μm and 365 μm laser fibers were used with a flexible and semirigid scope, respectively. Ablation was carried out with a 10 to 20 W power. Mean age at surgery was 68 years (SD 10.7). Mean tumor size was 14.3 mm (range 2-30 mm). Preliminary biopsy revealed the presence of low-grade disease in 29 (69.1%) patients, high-grade disease in 4 (9.5%) and 1 carcinoma in situ 1 (2.4%), whereas it was not conclusive in 8 (19%) cases. Final stage was pTa and pTis in 41 (97.6%) and 1 (2.4%) patients, respectively. Thirty eight percent (16) experienced Clavien-Dindo grade I complication, 47.6% (20) grade II, and 2.4% (1) grade III. Five (12%) patients underwent a second-look procedure due to residual disease. Eight (19%) patients experienced clinical recurrence. The median estimated recurrence-free survival was 44 months (SE 3.68). Four patients (9.5%) underwent a nephroureterectomy. Final pathological stage was pTis, pT3 high grade, pTa low grade, and pT0. Median follow-up was 26.3 months (range 2-54 months), and no progression or upstaging of disease occurred. TL management of UTUC is a safe and efficacious conservative treatment. Our experience shows optimal vaporization and hemostatic control in the absence of major complications.

  4. Evaluation Of Low Level Laser Therapy On Body Constitution And Leptin Hormone By Radioimmunoassay

    International Nuclear Information System (INIS)

    Ali, S.S.Y.

    2012-01-01

    Asymmetric fat distribution with excessive fat accumulation in particular areas often affects a person's self-image, self esteem, and overall quality of life. Purpose of the study: to investigate the efficacy of the low level laser therapy (LLLT) on body constitution and leptin hormone by radioimmunoassay. Methods: Twenty women were included in this study. Their ages ranged from 30- 40 years. They were divided into two groups of equal number. Procedures: -Group A (Overweight group): included 10 women with BMI ≥ 25- 29.9-Group B (Obese group): included 10 women with BMI ≥ 30.both groups received LLLT, for 30 minutes, 2 times per week for 8 weeks as a total period of treatment. BMI, WC, HC, WHR, serum Leptin, cholesterol and triglyceride level were measured before and after finishing the study. Results: There was significant improvement in anthropometric measurements( on both abdomen and thigh fats) of both groups treated with low level laser therapy, decrease in serum leptin level in over weight group and increase in triglyceride serum level in both groups within normal level Conclusion: low level laser therapy is effective as a noninvasive and safe method of body contouring .

  5. Diatomic gasdynamic lasers.

    Science.gov (United States)

    Mckenzie, R. L.

    1972-01-01

    Predictions from a numerical model of the vibrational relaxation of anharmonic diatomic oscillators in supersonic expansions are used to show the extent to which the small anharmonicity of gases like CO can cause significant overpopulations of upper vibrational states. When mixtures of CO and N2 are considered, radiative gain on many of the vibration-rotation transitions of CO is predicted. Experiments are described that qualitatively verify the predictions by demonstrating laser oscillation in CO-N2 expansions. The resulting CO-N2 gasdynamic laser displays performance characteristics that equal or exceed those of similar CO2 lasers.

  6. Diatomic gasdynamic lasers

    International Nuclear Information System (INIS)

    McKenzie, R.L.

    1971-12-01

    Predictions from a numerical model of the vibrational relaxation of anharmonic diatomic oscillators in supersonic expansions are used to show the extent to which the small anharmonicity of gases like CO can cause significant over-populations of upper vibrational states. When mixtures of CO and N 2 are considered, radiative gain on many of the vibration-rotation transitions of CO is predicted. Experiments are described that qualitatively verify the predictions by demonstrating laser oscillation in CO-N 2 expansions. The resulting CO-N 2 gasdynamic laser displays performance characteristics that equal or exceed those of similar CO 2 lasers

  7. Radiation level analysis for the port cell of the ITER electron cyclotron-heating upper launcher

    Energy Technology Data Exchange (ETDEWEB)

    Weinhorst, Bastian, E-mail: bastian.weinhorst@kit.edu [KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Fischer, Ulrich; Lu, Lei [KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Strauss, Dirk; Spaeh, Peter; Scherer, Theo [KIT, Institute for Applied Materials, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Leichtle, Dieter [F4E, Analysis & Codes/Technical Support Services, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain)

    2016-11-01

    Highlights: • First detailed neutronic modelling of the ECHUL port cell with ECHUL equipment (including beam lines with diamond windows, the beam lines mounting box, conduit boxes and rails). • Three different bioshield port plug configurations and two different neutron source configurations are investigated. • Radiation Levels are calculated in the port cell, focusing on the position of the diamond window. • The dose rate in the port cell is below the limit for maintenance in the port cell. • The radiation level at the diamond window is very low and should not influence its performance. - Abstract: The electron cyclotron-heating upper launcher (ECHUL) will be installed in four upper ports of the ITER tokamak thermonuclear fusion reactor. Each ECHUL is able to deposit 8 MW power into the plasma for plasma mode stabilization via microwave beam lines. An essential part of these beam lines are the diamond windows. They are located in the upper port cell behind the bioshield to reduce the radiation levels to a minimum. The paper describes the first detailed neutronic modelling of the ECHUL port cell with ECHUL equipment. The bioshield plug is modelled including passageways for the microwave beam lines, piping and cables looms as well as rails and openings for ventilation. The port cell is equipped with the beam lines including the diamond windows, the beam lines mounting box, conduit boxes and rails. The neutrons are transported into the port cell starting from a surface source in front of the bioshield. Neutronic results are obtained for radiation levels in the port cell at different positions, mainly focusing on the diamond windows position. It is shown that the radiation level is below the limit for maintenance in the port cell. The radiation level at the diamond window is very low and should not influence its performance.

  8. Effect of interstitial low level laser stimulation in skin density

    Science.gov (United States)

    Jang, Seulki; Ha, Myungjin; Lee, Sangyeob; Yu, Sungkon; Park, Jihoon; Radfar, Edalat; Hwang, Dong Hyun; Lee, Han A.; Kim, Hansung; Jung, Byungjo

    2016-03-01

    As the interest in skin was increased, number of studies on skin care also have been increased. The reduction of skin density is one of the symptoms of skin aging. It reduces elasticity of skin and becomes the reason of wrinkle formation. Low level laser therapy (LLLT) has been suggested as one of the effective therapeutic methods for skin aging as in hasten to change skin density. This study presents the effect of a minimally invasive laser needle system (MILNS) (wavelength: 660nm, power: 20mW) in skin density. Rabbits were divided into three groups. Group 1 didn't receive any laser stimulation as a control group. Group 2 and 3 as test groups were exposed to MILNS with energy of 8J and 6J on rabbits' dorsal side once a week, respectively. Skin density of rabbits was measured every 12 hours by using an ultrasound skin scanner.

  9. 激光用于儿童上唇系带矫正术的临床观察%Clinical evaluation of child' s upper labial frenum correction using laser

    Institute of Scientific and Technical Information of China (English)

    徐可卿; 昝绍华; 吴迪; 任畅

    2013-01-01

    Objective To evaluate the effect of laser on child's upper labial frenum correction. Methods Seven children with lower attachment of upper labial freunm received upper labial frenum correction using laser. The short-term and long-term outcomes were evaluated after 1 week, 2 weeks, 3 weeks, 6 months and 12 months respectively. Results There was no hemorrhage, no suture, shorter time pain, no relapse and scar afer the operation, and a shorter operation duration was in need. The wounds healed after 3 weeks. Conclusion Child's upper labial frenum correction using laser is an efficient, safe and minimal invasive operation without pain.%目的 观察用激光对上唇系带附丽过低患儿进行矫正以减小上颌两侧中切牙之间过大间隙的临床效果.方法 7例上唇系带附丽过低造成上颌两侧中切牙之间间隙过大的患儿,在必兰局麻下用激光进行上唇系带矫正术,观察术后的临床效果.结果 术中不出血,无需缝合,手术切割时间30~60 s.术后无疼痛,可立即饮食,术后3周切口愈合,随访4 ~15个月,无复发,上颌两侧中切牙之间间隙减小.结论 激光用于儿童上唇系带附丽过低矫正术是无痛、高效、安全的,对由上唇系带附丽过低造成的上颌两侧中切牙之间间隙过大效果良好.

  10. Evaluation of the efficacy of low-level laser in improving the symptoms of burning mouth syndrome.

    Science.gov (United States)

    Arbabi-Kalati, Fateme; Bakhshani, Nour-Mohammad; Rasti, Maryam

    2015-10-01

    Burning mouth syndrome (BMS) is common conditions that affects menopause women, patients suffer from sever burning sensation. Up to now there is no definitive treatment for this disease. Present study was undertaken to evaluate the efficacy of low-level laser (LLL) in improving the symptoms of burning mouth syndrome. Twenty patients with BMS were enrolled in this study; they were divided in two groups randomly. In the laser group, in each patient, 10 areas on the oral mucosa were selected and underwent LLL irradiation at a wavelength of 630 nm, and a power of 30 mW for 10 seconds twice a week for 4 weeks. In the placebo group, silent/off laser therapy was carried out during the same period in the same areas. Burning sensation and quality of life were evaluated. Burning sensation severity and quality of life in the two groups after intervention were different significant statistically, (p= 0.004, p= 0.01 respectively) .Patients in laser group had better results. It can be concluded that low level laser might decrease the intensity of burning mouth syndrome. Pain, low-level laser, burning mouth syndrome, oral mucosa.

  11. Chiropractic management of Bell palsy with low level laser and manipulation: a case report.

    Science.gov (United States)

    Rubis, Lisa M

    2013-12-01

    The purpose of this case report is to describe chiropractic management including the use of cold laser and chiropractic manipulation in the treatment of a patient with Bell palsy. A 40-year-old male patient had a 10-day history of facial paralysis on his left side, including the inability to close his left eye, which also had tearing and a burning sensation. The patient had trouble lifting his left lip and complained of drooling while brushing his teeth. There was no previous history of similar symptoms or a recent infection. Prior treatment had included oral steroids. The patient was treated with low-level laser therapy and chiropractic manipulation 2 times in 4 days. The laser was applied along the course of the facial nerve for 30 seconds at each point and for 1 minute at the stylomastoid foramen. The laser used was a GaAs class 4 laser with a wavelength of 910 nm. The patient perceived a 70% to 80% improvement of facial movement after the first treatment. After the second treatment, the patient reported full control of his facial movements. A patient with acute facial paralysis appeared to have complete resolution of his symptoms following the application of low-level laser therapy and chiropractic manipulation.

  12. Comparison of the effects of 665 nm low level diode Laser Hat versus and a combination of 665 nm and 808nm low level diode Laser Scanner of hair growth in androgenic alopecia.

    Science.gov (United States)

    Barikbin, Behrooz; Khodamrdi, Zeinab; Kholoosi, Leila; Akhgri, Mohammad Reza; Haj Abbasi, Majid; Hajabbasi, Mojgan; Razzaghi, Zahra; Akbarpour, Samaneh

    2017-05-17

    This study aimed to evaluate the effectiveness of a combined set of low level diode laser scanner (665 nm and 808nm) on hair growth, and assessment of safety and effectiveness of a new laser scanner on hair growth treatment procedure in androgenic alopecia. 90 patients (18 to 70 years) with androgenic alopecia were randomized into three groups. The first group (n=30) received 655 nm red light using laser hat, the second group (n=30) received 655 nm red laser plus 808 nm infrared laser using a laser scanner of hair growth device (with the patent number: 77733) and the third group (n=30) received no laser as the control group. Patients in laser scanner group had better results and showed a higher increase in terminal hair density compared with laser hat group (mean of 9.61 versus 9.16 per cm 2 ). We found significant decrease in terminal hair density from baseline in control group (mean -1.8 per cm 2 , plaser scanner of the hair growth group compared with laser hat and the control group. The study showed that treatment with new laser devise had a promising result without any observable adverse effects.

  13. Effect of low-level laser therapy on tooth sensitivity induced by in-office bleaching.

    Science.gov (United States)

    Moosavi, Horieh; Arjmand, Nooshin; Ahrari, Farzaneh; Zakeri, Majid; Maleknejad, Fatemeh

    2016-05-01

    This study aimed to investigate the effect of low-level laser therapy (LLLT) on tooth sensitivity induced by in-office bleaching. Sixty-six patients enrolled in this randomized clinical trial. Following the in-office procedure with 40% hydrogen peroxide, the participants were randomly divided into three groups. The patients in group 1 received irradiation from a low-level red laser (LLRL; 660 nm, 200 mW, 15 s, 12 J/cm(2)), whereas participants in group 2 were subjected to a low-level infrared laser (LLIL; 810 nm) under similar conditions as in group 1. In group 3 (placebo), the laser treatment was the same as that in groups 1 and 2, but without energy output. The degree of tooth sensitivity was recorded at 1, 24, and 48 h after bleaching using a visual analog scale (VAS). The change in tooth shade was measured 30 days after tooth whitening. The intensity of tooth sensitivity was not significantly different between groups at 1 h after bleaching (p > 0.05). At 24 h after therapy, pain level was significantly lower in the LLIL group compared to the LLRL and placebo groups (p bleaching, VAS scores in the LLIL and LLRL groups were comparable to each other (p > 0.05) and both were significantly lower than that of the placebo group (p  0.05). LLLT with an infrared diode laser could be recommended as a suitable strategy to reduce the intensity of tooth sensitivity after in-office bleaching.

  14. Population inversion and gain measurements for soft x-ray-laser development in a magnetically confined plasma column

    International Nuclear Information System (INIS)

    Suckewer, S.; Skinner, C.H.; Voorhees, D.; Milchberg, H.; Keane, C.; Semet, A.

    1983-06-01

    We present population inversion and gain measurements from an experimental investigation of possibilities to obtain high gain and lasing action in the soft x-ray region. Our approach to soft x-ray-laser development is based on rapid plasma cooling after the laser pulse by radiation losses, leading to fast recombination and collisional cascade into upper excited levels of CVI, for example, while the lower excited levels depopulate rapidly by radiative transitions, thus creating population inversions and gain. A approx. = 0.5 kJ CO 2 laser was focused onto a target of solid carbon or teflon; or CO 2 , O 2 , Ne gas, and the resulting plasma confined in a 50 to 90 kG magnetic field. Spectroscopic diagnostics with absolute intensity calibration were used to measure level populations

  15. 50W CW output power and 12mJ pulses from a quasi-2-level Yb:YAG ceramic rod laser end-pumped at the 969nm zero-phonon line

    Science.gov (United States)

    Fries, Christian; Weitz, Marco; Theobald, Christian; v. Löwis of Menar, Patric; Bartschke, Jürgen; L'huillier, Johannes A.

    2015-02-01

    With the advent of high power and narrow bandwidth 969 nm pump diodes, direct pumping into the upper laser level of Yb:YAG and hence quasi-2-level lasers became possible. Pumping directly into the emitting level leads to higher quantum efficiency and reduction of non-radiative decay. Consequently, thermal load, thermal lensing and risk of fracture are reduced significantly. Moreover pump saturation and thermal population of uninvolved energy-levels in ground and excited states are benefical for a homogenous distribution of the pump beam as well as the reduction of reabsorption loss compared to 3-level systems, which allows for high-power DPSS lasers. Beside continuous-wave (cw) operation, nanosecond pulses with a repetition rate between 1 and 5 kHz are an attractive alternative to flashlamp-pumped systems (10-100 Hz) in various measurement applications that require higher data acquisition rates because of new faster detectors. Based on measurements of the absorption and a detailed numerical model for pump beam distribution, including beam propagation and saturation factors, power-scaling of a ceramic rod Yb:YAG oscillator was possible. Finally a cw output power of 50 W with 33 % pump efficiency at 1030 nm has been demonstrated (M2 dumping of this system. The cavity-dumped setup allowed for 3-10 ns pulses with a pulse energy of 12.5 mJ at 1 kHz (M2 < 1.1). In order to achieve these results a systematic experimental and numerical investigation on gain dynamics and the identification of different stable operating regimes has been carried out.

  16. Effects of low-level laser therapy on burning mouth syndrome.

    Science.gov (United States)

    Valenzuela, S; Lopez-Jornet, P

    2017-02-01

    To investigate low-level laser therapy (LLLT) applied to treat burning mouth syndrome (BMS). This prospective, comparative, partially blinded, single-centre, clinical trial of GaAlAs Laser, with 815 nm wavelength, included 44 BMS patients divided randomly into three groups: Group I (n = 16): GaAlAs laser 815 nm wavelength, 1 W output power, continuous emissions, 4 s, 4 J and fluence rate 133·3 J cm -2 ; Group II (n = 16): GaAlAs infrared laser, 815 nm wavelength, 1 W output power, continuous emissions, 6 s, 6 J and fluence rate 200 J cm -2 ; Group III (n = 12) placebo group, sham laser. All groups received a weekly dose for 4 weeks. Pain intensity was recorded using a 10-cm visual analogue scale; patients responded to the oral health impact profile (OHIP-14), xerostomia severity test and the hospital anxiety-depression scale (HAD). These assessments were performed at baseline, 2 and 4 weeks. LLLT decreased pain intensity and improved OHIP-14 scores significantly from baseline to 2 weeks in groups I and II compared with the placebo group. No statistically significant differences were found from 2 to 4 weeks. Overall improvements in visual analogue scale (VAS) scores from baseline to the end of treatment were as follows: Group I 15·7%; Group II 15·6%; Group III placebo 7·3%. LLLT application reduces symptoms slightly in BMS patients. © 2016 John Wiley & Sons Ltd.

  17. Excitation of high energy levels under laser exposure of suspensions of nanoparticles in liquids

    Energy Technology Data Exchange (ETDEWEB)

    Shafeev, G.A. [Wave Research Center of A.M. Prokhorov General Physics Institute, 38, Vavilov Street, 119991 Moscow (Russian Federation)], E-mail: shafeev@kapella.gpi.ru; Simakin, A.V. [Wave Research Center of A.M. Prokhorov General Physics Institute, 38, Vavilov Street, 119991 Moscow (Russian Federation); Bozon-Verduraz, F. [ITODYS, UMR CNRS 7086, Universite Paris 7-Denis Diderot, 2, place Jussieu, 75251 Paris cedex 05 (France); Robert, M. [Laboratoire d' Electrochimie Moleculaire, UMR CNRS 7591, Universite Paris 7 Denis Diderot, 2, place Jussieu, 75251 Paris cedex 05 (France)

    2007-12-15

    Laser exposure of suspensions of nanoparticles in liquids leads to excitation of high energy levels in both liquid and nanoparticle material. The emission spectrum of the colloidal solution under exposure of a suspension metallic nanoparticles in water to radiation of a Nd:YAG laser of a picosecond range of pulse duration is discussed. Excitation of nuclear energy levels and neutron release is experimentally studied on the model system of transmutation of Hg into Au that occurs under exposure of Hg nanodrops suspended in D{sub 2}O. The proposed mechanism involves: (i) emission of X-ray photons by Hg nanoparticles upon laser exposure, leading to neutron release from D{sub 2}O, (ii) initiation of Hg {yields} Au transmutation by the capture of neutrons. The effect of transmutation is more pronounced using {sup 196}Hg isotope instead of Hg of natural isotope composition. The influence of laser pulse duration on the degree of transmutation (from fs through ns range) is discussed.

  18. Low-level laser therapy: An experimental design for wound management: A case-controlled study in rabbit model

    Directory of Open Access Journals (Sweden)

    Hossein Hodjati

    2014-01-01

    Full Text Available Background: There is a wide array of articles in medical literature for and against the laser effect on wound healing but without discrete effect determination or conclusion. This experimental study aims to evaluate the efficacy of low-level laser therapy on wound healing. Materials and Methods: Thirty-four rabbits were randomly enrolled in two groups after creating a full thickness of 3 × 3 cm wound. The intervention group received low density laser exposure (4 J/cm 2 on days 0, 3 and 6 with diode helium-neon low-intensity laser device (wl = 808 nm and in control group moist wound dressing applied. Finally, wound-healing process was evaluated by both gross and pathological assessment. Results: Fibrin formation was the same in the two groups (P = 0.4 but epithelialisation was much more in laser group (P = 0.02. Wound inflammation of the laser group was smaller than that of the control groups but statistical significance was not shown (P = 0.09. Although more smooth muscle actin was found in the wounds of the laser group but it was not statistically significant (P = 0.3. Wound diameter showed significant decrease in wound area in laser group (P = 0.003. Conclusion: According to our study, it seems that low-level laser therapy accelerates wound healing at least in some phases of healing process. So, we can conclude that our study also shows some hopes for low level laser therapy effect on wound healing at least in animal model.

  19. Diode-pumped two micron solid-state lasers

    International Nuclear Information System (INIS)

    Elder, I.F.

    1997-01-01

    This thesis presents an investigation of diode-pumped two micron solid-state lasers, concentrating on a comparison of the cw room temperature operation of Tm:YAP, Tm,Ho:YAP and Tm,Ho:YLF. Dopant concentrations in YAP were 4.2% thulium and 0.28% holmium; in YLF they were 6% thulium and 0.4% holmium. Thermal modelling was carried out in order to provide an insight into the thermal lensing and population distributions in these materials. Laser operation was achieved utilising an end-pumping geometry with a simple two mirror standing wave resonator. The pump source for these experiments was a 3 W laser diode. Maximum output power was achieved with Tm:YAP, generating 730 mW of laser output, representing 42% conversion efficiency in terms of absorbed pump power. Upper bounds on the conversion efficiency of Tm,Ho:YAP and Tm,Ho:YLF laser crystal of 14% and 30% were obtained, with corresponding output powers of 270 and 660 mW. In all three cases, the output beam was TEM 00 in nature. Visible upconversion fluorescence bands in the green and red were identified in Tm,Ho:YAP and Tm,Ho:YLF, with additional blue emission from the latter, all assigned to transitions on holmium. The principal upconversion mechanisms in these materials all involved the holmium first excited state. Upconversion in Tm:YAP was negligible. The spectral output of Tm:YAP consisted of a comb of lines in the range 1.965 to 2.020 μm. For both the double-doped crystals, the laser output was multilongitudinal mode on a single transition, wavelength 2.120 μm in YAP, 2.065 μm in YLF. In the time domain the output of Tm:YAP was dominated by large amplitude spiking, unlike both of the double-doped laser crystals. The long lifetime of the thulium upper laser level (4.4 ms) provided very weak damping of the spiking. Excitation sharing between thulium and holmium, with a measured characteristic lifetime in YAP of 11.9 μs and YLF of 14.8 μs, provided strong damping of any spiking behaviour. (author)

  20. Low level diode laser accelerates wound healing.

    Science.gov (United States)

    Dawood, Munqith S; Salman, Saif Dawood

    2013-05-01

    The effect of wound illumination time by pulsed diode laser on the wound healing process was studied in this paper. For this purpose, the original electronic drive circuit of a 650-nm wavelength CW diode laser was reconstructed to give pulsed output laser of 50 % duty cycle and 1 MHz pulse repetition frequency. Twenty male mice, 3 months old were used to follow up the laser photobiostimulation effect on the wound healing progress. They were subdivided into two groups and then the wounds were made on the bilateral back sides of each mouse. Two sessions of pulsed laser therapy were carried along 15 days. Each mice group wounds were illuminated by this pulsed laser for 12 or 18 min per session during these 12 days. The results of this study were compared with the results of our previous wound healing therapy study by using the same type of laser. The mice wounds in that study received only 5 min of illumination time therapy in the first and second days of healing process. In this study, we found that the wounds, which were illuminated for 12 min/session healed in about 3 days earlier than those which were illuminated for 18 min/session. Both of them were healed earlier in about 10-11 days than the control group did.

  1. Diode-pumped 2.8-μm laser emission from Er/sup 3+/:YLF at room temperature

    International Nuclear Information System (INIS)

    Kintz, G.J.; Allen, R.; Esterowitz, L.

    1987-01-01

    This paper details laser emission from an erbium-doped LiYF/sub 4/ sample longitudinally pumped at room temperature with a laser diode array observed in both pulsed and cw pumping. The threshold for pulsed emission is much less than for cw emission due to the lifetime of the terminal laser level being longer than the upper laser level. Depopulation of the lower laser level, which permits cw operation, is due to a cooperative upconversion process. The threshold energy for pulsed emission is 28 μJ when pumped with a 300-μs diode pulse. At 147 mW of diode power the threshold for cw emission occurs. The system relaxes to a steady state after 40 ms. The threshold for cw emission corresponds to --62 mW of diode power being absorbed into the crystal. Pulsed outputs of 21 μJ and cw outputs of 180 μW have been obtained. These low outputs and correspondingly low efficiencies are due to currently operating near threshold and in the self-terminating mode of the laser system. Higher concentrations and higher pumping rates should significantly improve the efficiency

  2. Electronic defect levels in continuous wave laser annealed silicon metal oxide semiconductor devices

    Science.gov (United States)

    Cervera, M.; Garcia, B. J.; Martinez, J.; Garrido, J.; Piqueras, J.

    1988-09-01

    The effect of laser treatment on the bulk and interface states of the Si-SiO2 structure has been investigated. The annealing was performed prior to the gate metallization using a continuous wave Ar+ laser. For low laser powers the interface state density seems to decrease slightly in comparison with untreated samples. However, for the highest irradiating laser powers a new bulk level at 0.41 eV above the valence band with concentrations up to 1015 cm-3 arises probably due to the electrical activation of the oxygen diluted in the Czochralski silicon. Later postmetallization annealings reduce the interface state density to values in the 1010 cm-2 eV-1 range but leave the concentration of the 0.41-eV center nearly unchanged.

  3. Student Perceived and Determined Knowledge of Biology Concepts in an Upper-Level Biology Course

    Science.gov (United States)

    Ziegler, Brittany; Montplaisir, Lisa

    2014-01-01

    Students who lack metacognitive skills can struggle with the learning process. To be effective learners, students should recognize what they know and what they do not know. This study examines the relationship between students' perception of their knowledge and determined knowledge in an upper-level biology course utilizing a pre/posttest…

  4. "The comparison between effects of two general anesthesia techniques; Intermittent apenic technique and continuous controlled ventilation in upper airway Laser therapy "

    Directory of Open Access Journals (Sweden)

    Khagavy MR "

    2002-11-01

    Full Text Available Introduction: Laser beam due to finest of incision and reduction of postoperative complication, facilitates airway surgery, but at the same time it increases the danger or firing and the airway management and protection becomes difficult during anesthesia. In this study, two general anesthesia methods; (Intermittent Apneic Technique And Continuous Controlled Ventilation With Enveloped Endotracheal Tube have been compared with each other mater. Materials and methods: two groups, each consist of 25 patients 10 to 60 years old, and ASA I-II class and below 100kg weight who have been candidate for laser therapy, were given two mentioned methods of anesthesia. All patients were suffering from subglotic stenosis, vocal cord nodules, papillomatosis and oropharyngeal obstruction. Induction and maintenance of anesthesia, and monitoring during surgery (EGG, PETCO2, SaPo2, BP, PR in both groups were the same. Results: Homodynamic stability in the both groups were the same and there was no hypoxia and dysrhythmia. In apneic technique group, most of the surgeries needed 2-3 time of apnea, and each apnea duration was 2-4 minutes, without any hypercaphic (Peteco 2>47 mmHg and hypoxic (Spo2<90 percent state and duration of laser surgery was about 9-10 minutes. More satisfaction was gained with apneic technique because of having a better surgery filed. All the patients had no recall at the end of anesthesia and patietn's expenses were much lower with no danger of firing. Conclusion: It has been concluded that intermittent apneic technique in upper airway laser therapy is a better technique of anesthesia.

  5. Laser in urology

    International Nuclear Information System (INIS)

    Breisland, H.O.

    1991-01-01

    The neodymium YAG laser is particularly suited for endoscopic urologic surgery because the YAG laser light can be conducted in flexible fibers. Superficial bladder tumours can be treated under local anaesthesia in the outpatient department. The frequency of local recurrences is low, significantly lower than after electrosection or electrocoagulation. Selected cases of T2-muscle invasive bladder tumours can be cured with laser coagulation applied subsequently to transurethral resection. Combined treatment with electrosection and laser coagulation of localized prostatic cancer is a promising method which compares favourably with results obtained by other treatment modalities. Tumours in the upper urinary tract can be laser-treated through ureteroscopes or nephroscopes, but the treatment should be limited to low stage, low grade tumours. Laser is the treatment of choice for intraurethral condylomatas. Laser treatment of penil carcinoma gives excellent cosmetic and functional results and few local recurrences. Laser lithotripsy is a new technique for treatment of ureteric stones and photodynamic laser therapy is a promising tecnique for treatment of carcinoma in situ in the bladder empithelium. However, neither of these techniques are available for clinical use in Norway as yet. 17 refs., 3 figs., 1 tabs

  6. Classification of upper limb disability levels of children with spastic unilateral cerebral palsy using K-means algorithm.

    Science.gov (United States)

    Raouafi, Sana; Achiche, Sofiane; Begon, Mickael; Sarcher, Aurélie; Raison, Maxime

    2018-01-01

    Treatment for cerebral palsy depends upon the severity of the child's condition and requires knowledge about upper limb disability. The aim of this study was to develop a systematic quantitative classification method of the upper limb disability levels for children with spastic unilateral cerebral palsy based on upper limb movements and muscle activation. Thirteen children with spastic unilateral cerebral palsy and six typically developing children participated in this study. Patients were matched on age and manual ability classification system levels I to III. Twenty-three kinematic and electromyographic variables were collected from two tasks. Discriminative analysis and K-means clustering algorithm were applied using 23 kinematic and EMG variables of each participant. Among the 23 kinematic and electromyographic variables, only two variables containing the most relevant information for the prediction of the four levels of severity of spastic unilateral cerebral palsy, which are fixed by manual ability classification system, were identified by discriminant analysis: (1) the Falconer index (CAI E ) which represents the ratio of biceps to triceps brachii activity during extension and (2) the maximal angle extension (θ Extension,max ). A good correlation (Kendall Rank correlation coefficient = -0.53, p = 0.01) was found between levels fixed by manual ability classification system and the obtained classes. These findings suggest that the cost and effort needed to assess and characterize the disability level of a child can be further reduced.

  7. Enhancement of low power CO2 laser cutting process for injection molded polycarbonate

    Science.gov (United States)

    Moradi, Mahmoud; Mehrabi, Omid; Azdast, Taher; Benyounis, Khaled Y.

    2017-11-01

    Laser cutting technology is a non-contact process that typically is used for industrial manufacturing applications. Laser cut quality is strongly influenced by the cutting processing parameters. In this research, CO2 laser cutting specifications have been investigated by using design of experiments (DOE) with considering laser cutting speed, laser power and focal plane position as process input parameters and kerf geometry dimensions (i.e. top and bottom kerf width, ratio of the upper kerf to lower kerf, upper heat affected zone (HAZ)) and surface roughness of the kerf wall as process output responses. A 60 Watts CO2 laser cutting machine is used for cutting the injection molded samples of polycarbonate sheet with the thickness of 3.2 mm. Results reveal that by decreasing the laser focal plane position and laser power, the bottom kerf width will be decreased. Also the bottom kerf width decreases by increasing the cutting speed. As a general result, locating the laser spot point in the depth of the workpiece the laser cutting quality increases. Minimum value of the responses (top kerf, heat affected zone, ratio of the upper kerf to lower kerf, and surface roughness) are considered as optimization criteria. Validating the theoretical results using the experimental tests is carried out in order to analyze the results obtained via software.

  8. Absorption of the laser radiation by the laser plasma with gas microjet targets

    Science.gov (United States)

    Borisevichus, D. A.; Zabrodskii, V. V.; Kalmykov, S. G.; Sasin, M. E.; Seisyan, R. P.

    2017-01-01

    An upper limit of absorption of the laser radiation in the plasma produced in a gas jet Xe target with the average density of (3-6) × 1018 cm-3 and the effective diameter of 0.7 mm is found. It is equal to ≈50% and remains constant under any variation in this range of densities. This result contradicts both theoretical assessments that have predicted virtually complete absorption and results of earlier experiments with the laser spark in an unlimited stationary Xe gas with the same density, where the upper limit of absorption was close to 100%. An analysis shows that nonlinearity of absorption and plasma nonequilibrium lead to the reduction of the absorption coefficient that, along with the limited size of plasma, can explain the experimental results.

  9. Low Level Laser Therapy for chronic knee joint pain patients.

    Science.gov (United States)

    Nakamura, Takashi; Ebihara, Satoru; Ohkuni, Ikuko; Izukura, Hideaki; Harada, Takashi; Ushigome, Nobuyuki; Ohshiro, Toshio; Musha, Yoshiro; Takahashi, Hiroshi; Tsuchiya, Kazuaki; Kubota, Ayako

    2014-12-27

    Chronic knee joint pain is one of the most frequent complaints which is seen in the outpatient clinic in our medical institute. In previous studies we have reported the benefits of low level laser therapy (LLLT) for chronic pain in the shoulder joints, elbow, hand, finger and the lower back. The present study is a report on the effects of LLLT for chronic knee joint pain. Over the past 5 years, 35 subjects visited the outpatient clinic with complaints of chronic knee joint pain caused by the knee osteoarthritis-induced degenerative meniscal tear. They received low level laser therapy. A 1000 mW semi-conductor laser device was used to deliver 20.1 J/cm(2) per point in continuous wave at 830nm, and four points were irradiated per session (1 treatment) twice a week for 4 weeks. A visual analogue scale (VAS) was used to determine the effects of LLLT for the chronic pain and after the end of the treatment regimen a significant improvement was observed (pknee joint range of motion. Discussions with the patients revealed that it was important for them to learn how to avoid postures that would cause them knee pain in everyday life in order to have continuous benefits from the treatment. The present study demonstrated that 830 nm LLLT was an effective form of treatment for chronic knee pain caused by knee osteoarthritis. Patients were advised to undertake training involving gentle flexion and extension of the knee.

  10. Diode-pumped quasi-three-level CW Nd:CLNGG and Nd:CNGG lasers.

    Science.gov (United States)

    He, Kunna; Wei, Zhiyi; Li, Dehua; Zhang, Zhiguo; Zhang, Huaijin; Wang, Jiyang; Gao, Chunqing

    2009-10-12

    We have demonstrated what is to our knowledge the first quasi-three-level CW Nd:CLNGG laser with simple linear resonator. When the pump power was 18.2 W, a maximum output power of 1.63 W was obtained at the dual-wavelength of 935 nm and 928 nm. The optical-to-optical conversion efficiency was 9.0% and the slope efficiency was 11.5%. Lasing characteristics of a quasi-three-level CW Nd:CNGG laser were also investigated. A maximum output power of 1.87 W was obtained at the single-wavelength of 935 nm with 15.2 W pump power, corresponding to an optical-to-optical conversion efficiency of 12.3% and a slope efficiency of 15.6%.

  11. Decay kinetics of Krsup(*) levels populated by ArF laser radiation

    International Nuclear Information System (INIS)

    Wren, D.J.; Setser, D.W.

    1981-01-01

    The Kr 6p [3/2] 2 (or 3p 6 ) level was pumped via a two-photon absorption using a focused ArF laser (193 nm). The time dependent fluorescence from excited Kr levels was observed using a monochromator and photomultiplier tube and transient digitizer. Fluorescence from the pumped level, observed via the 3p 6 → 1s 5 transition, has a lifetime of 8 +- 2 ns independent of the Kr pressure (2-30 Torr). Fluorescence from other levels of the Kr (4p 5 6p) manifold was either unobserved or weak. Strong fluorescence was observed from the Kr (4p 5 5p) levels via transitions to the Kr (4p 5 5s) levels, the highest populated levels being 2p 6 , 2p 8 and 2p 9 . All Kr (4p 5 5p) levels display effective lifetimes much longer than the radiative lifetimes; effective zero pressure lifetimes for Kr 2p 3 , 2p 6 and 2p 7 are 72 +- 15, 66 +- 15 and 90 +- 15 ns, respectively. The short lifetime of the Kr (3p 6 ) level is explained by very fast collisional depopulation by photoelectrons produced in three photon ionization of Kr by the ArF laser. The Kr (4p 5 5p) levels are populated indirectly from the Kr (3p 6 ) level and the long lifetimes of the Kr (4p 5 5p) levels represent the lifetime of the intermediate state (or states) which lead to the Kr (4p 5 5p) levels. Strong possibilities for the intermediate states are the Kr (4p 5 4d) levels. (orig.)

  12. Lifetime measurements of odd-parity high-excitation levels of Sn I by time-resolved laser spectroscopy

    International Nuclear Information System (INIS)

    Zhang, Wei; Feng, Yanyan; Xu, Jiaxin; Dai, Zhenwen; Palmeri, Patrick; Quinet, Pascal; Biemont, Emile

    2010-01-01

    Natural radiative lifetimes of 38 odd-parity highly excited levels in neutral tin in the energy range from 43 682.737 to 56 838.68 cm -1 have been measured by a time-resolved laser-induced fluorescence technique in an atomic beam produced by laser ablation on a solid tin sample. All the levels were excited from the metastable 3 P 1, 2 and 1 D 2 levels in the ground configuration. The second and third harmonics of a dye laser were adopted as the tunable exciting source (207-250 nm). The lifetime results obtained in this paper are in the range from 4.6 to 292 ns and will be useful in extending the set of oscillator strengths available in Sn I.

  13. Assessment of the effectiveness of low level laser in the treatment of alveolar osteitis

    Directory of Open Access Journals (Sweden)

    Jovanović Goran

    2011-01-01

    Full Text Available Background/Aim. Alveolar osteitis (AO is the extraction wound healing disorder with a presence of severe pain. Low level laser therapy stimulates cell metabolism and microcirculation, have has pronounced analgesic, antiedematous and anti-inflammatory effect and speeds up wound healing process. The aim of this study was to present results of clinical research that examined the effectiveness of low level laser in pain relief and healing of extraction wounds with alveolar osteitis in the lower jaw which was formed on the second day after tooth extraction. Methods. The study was conducted on 60 subjects divided into the study and the control group. In both groups extraction wounds were processed in similar way, except that in the study group was applied daily treatment of low level laser with a total of eight sessions of radiation, while in the control group extraction wounds were dressed with zinc oxide eugenol paste, which was changed every 48 hours up to the pain cessation. Measurement of pain intensity was done with a visual analogue scale (VAS 10 min prior to processing of extraction wounds and daily for the next eight days. Assessment of the effectiveness of low level laser on healing of extraction wounds was performed on the day eight of the treatment. Results. On the day five after beginning of the treatment of extraction wounds with alveolar osteitis in the patients of the study group a lower average value of pain as compared to the control group was registered. This difference was increased within the following days. Extraction wounds healing in the study group was more successful and faster than in the control group. Conclusion. This study suggested that the reduction of pain was more pronounced in the patients with alveolar osteitis whose extraction wounds were subjected to low level laser radiation in comparison to those in which extraction wounds were treated with zinc oxide eugenol paste.

  14. Toward a New Capability for Upper Atmospheric Research using Atomic Oxygen Lidar

    Science.gov (United States)

    Clemmons, J. H.; Steinvurzel, P.; Mu, X.; Beck, S. M.; Lotshaw, W. T.; Rose, T. S.; Hecht, J. H.; Westberg, K. R.; Larsen, M. F.; Chu, X.; Fritts, D. C.

    2017-12-01

    Progress on development of a lidar system for probing the upper atmosphere based on atomic oxygen resonance is presented and discussed. The promise of a fully-developed atomic oxygen lidar system, which must be based in space to measure the upper atmosphere, for yielding comprehensive new insights is discussed in terms of its potential to deliver global, height-resolved measurements of winds, temperature, and density at a high cadence. An overview of the system is given, and its measurement principles are described, including its use of 1) a two-photon transition to keep the optical depth low; 2) laser tuning to provide the Doppler information needed to measure winds; and 3) laser tuning to provide a Boltzmann temperature measurement. The current development status is presented with a focus on what has been done to demonstrate capability in the laboratory and its evolution to a funded sounding rocket investigation designed to make measurements of three-dimensional turbulence in the upper mesosphere and lower thermosphere.

  15. Diode-laser pumping into the emitting level for efficient lasing of depressed cladding waveguides realized in Nd:YVO4 by the direct femtosecond-laser writing technique.

    Science.gov (United States)

    Pavel, Nicolaie; Salamu, Gabriela; Jipa, Florin; Zamfirescu, Marian

    2014-09-22

    Depressed cladding waveguides have been realized in Nd:YVO(4) employing direct writing technique with a femtosecond-laser beam. It was shown that the output performances of such laser devices are improved by the reduction of the quantum defect between the pump wavelength and the laser wavelength. Thus, under the classical pump at 808 nm (i.e. into the (4)F(5/2) level), a 100-μm diameter circular waveguide inscribed in a 0.7-at.% Nd:YVO(4) outputted 1.06-μm laser pulses with 3.0-mJ energy, at 0.30 optical efficiency and slope efficiency of 0.32. The pump at 880 nm (i.e.directly into the (4)F(3/2) emitting level) increased the pulse energy at 3.8 mJ and improved both optical efficiency and slope efficiency at 0.36 and 0.39, respectively. The same waveguide yielded continuous-wave 1.5-W output power at 1.06 μm under the pump at 880 nm. Laser emission at 1.34 μm was also improved using the pump into the (4)F(3/2) emitting level of Nd:YVO(4).

  16. Immediate pain relief effect of low level laser therapy for sports injuries: Randomized, double-blind placebo clinical trial.

    Science.gov (United States)

    Takenori, A; Ikuhiro, M; Shogo, U; Hiroe, K; Junji, S; Yasutaka, T; Hiroya, K; Miki, N

    2016-12-01

    To determine the immediate pain relief effect of low-level laser therapy on sports injuries in athletes and degree of pain relief by the therapy. Double-blind, randomized, comparative clinical study. Participants were 32 college athletes with motion pain at a defined site. Participants were randomized into two groups in which the tested or placebo laser therapy was administered to determine pain intensity from painful action before and after laser irradiation, using the Modified Numerical Rating Scale. The post-therapeutic Modified Numerical Rating Scale score was subtracted from the pre-therapeutic Modified Numerical Rating Scale score to determine pain intensity difference, and the rate of pain intensity difference to pre-therapeutic Modified Numerical Rating Scale was calculated as pain relief rate. Low-level laser therapy was effective in 75% of the laser group, whereas it was not effective in the placebo group, indicating a significant difference in favor of the laser group (p<0.001). Pain relief rate was significantly higher in the laser group than in the placebo group (36.94% vs. 8.20%, respectively, p<0.001), with the difference in pain relief rate being 28.74%. Low-level laser therapy provided an immediate pain relief effect, reducing pain by 28.74%. It was effective for pain relief in 75% of participants. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Efficacy and Safety of Semirigid Ureteroscopy Combined with Holmium: YAG Laser in the Treatment of Upper Urinary Tract Calculi: Is it a Good Alternative Treatment Option of Flexible Ureteroscopy for Developing Countries

    International Nuclear Information System (INIS)

    Bibi, S.; Siddiqui, T. R.; Ahmed, W.; Alam, S. E.; Shah, S. A.; Soomro, I. A.; Qureshi, S.

    2015-01-01

    Objective: To assess the success rates of endoscopic management of upper ureteral stones using semirigid ureterorenoscopy and holmium: YAG laser lithotripters. Method: A total of 74 patients with an established diagnosis of upper ureteric stone and scheduled for endoscopic ureteral stone treatment were retrospectively evaluated. Failure was defined as the inability to contact or fragment the stone, migration of the stone into the renal pelvis and difficulty in visualizing the stone for the second time. Success rates and influencing factors as for stone-free state were investigated. Results: Mean age of our patients was 45.99±15.00 (range: 24-82) years. In 14 of 74 patients procedural failure was observed. Double J stents were implanted in 65 percent of the patients and ureteral catheterization was performed on 20 percent of them. The total success rate was 81.1 percent. Major complication rate was 1.1 percent. Factors effecting the success rate as gender, age, body mass index, grade of hydronephrosis and stone size were evaluated and only age was found to be statistically significant. Conclusion: Despite some potential risks, semirigid ureterorenoscopic stone extraction and holmium: YAG laser lithotripters are still safe and effective treatment alternatives for management of upper ureteral stones. (author)

  18. Trend of laser research developments in global level

    Science.gov (United States)

    Golnabi, H.; Mahdieh, M. H.

    2006-03-01

    An up-to-date progress of the international laser research and development is given in this article. The number of scientific publications and filed patents are considered as a figure of merit and based on these numbers the growth pace and important aspects are investigated. We have used the Science Finder Scholar search engine, which indexes more than 4000 journals, in different languages, and represents most significant published materials in laser science and engineering. The growth of the laser and related fields are described in terms of resulting scientific publications for the period of 1990-2003. The share of top nations in scientific publications, and in particular laser publications in terms of their gross domestic product (GDP) is presented. It is noted that the four countries including the USA, Japan, Germany and China have a laser publication contribution of 58.9% while the rest of the world including 189 countries contribute 41.1%. However, for the case of patent, which is a more important factor, these four countries hold a share of 90.1% while the remaining nations have a small share of 9.9%. The USA heads all the nations in the number of scientific publications, citations, and laser publications, however, in terms of accepted laser patents Japan shows a big lead. Scientific scopes of the laser systems are presented and some requirements to be met in each field are described. The key points in this field of research, which might be helpful in the future development of the laser technology are discussed.

  19. Creating intense polarized electron beam via laser stripping and spin-orbit interaction

    International Nuclear Information System (INIS)

    Danilov, V.; Ptitsyn, V.; Gorlov, T.

    2010-01-01

    The recent advance in laser field make it possible to excite and strip electrons with definite spin from hydrogen atoms. The sources of hydrogen atoms with orders of magnitude higher currents (than that of the conventional polarized electron cathods) can be obtained from H - sources with good monochromatization. With one electron of H - stripped by a laser, the remained electron is excited to upper state (2P 3/2 and 2P 1/2 ) by a circular polarization laser light from FEL. Then, it is excited to a high quantum number (n=7) with mostly one spin direction due to energy level split of the states with a definite direction of spin and angular momentum in an applied magnetic field and then it is stripped by a strong electric field of an RF cavity. This paper presents combination of lasers and fields to get high polarization and high current electron source.

  20. Lifetime measurements of odd-parity high-excitation levels of Sn I by time-resolved laser spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei; Feng, Yanyan; Xu, Jiaxin; Dai, Zhenwen [College of Physics, Jilin University and Key Lab of Coherent Light, Atomic and Molecular Spectroscopy, Ministry of Education, Changchun 130021 (China); Palmeri, Patrick; Quinet, Pascal; Biemont, Emile, E-mail: dai@jlu.edu.c [Astrophysique et Spectroscopie, Universite de Mons-UMONS, B-7000 Mons (Belgium)

    2010-10-28

    Natural radiative lifetimes of 38 odd-parity highly excited levels in neutral tin in the energy range from 43 682.737 to 56 838.68 cm{sup -1} have been measured by a time-resolved laser-induced fluorescence technique in an atomic beam produced by laser ablation on a solid tin sample. All the levels were excited from the metastable {sup 3}P{sub 1,} {sub 2} and {sup 1}D{sub 2} levels in the ground configuration. The second and third harmonics of a dye laser were adopted as the tunable exciting source (207-250 nm). The lifetime results obtained in this paper are in the range from 4.6 to 292 ns and will be useful in extending the set of oscillator strengths available in Sn I.

  1. Low-level laser therapy with helium-neon laser improved viability of osteoporotic bone marrow-derived mesenchymal stem cells from ovariectomy-induced osteoporotic rats

    Science.gov (United States)

    Fallahnezhad, Somaye; Piryaei, Abbas; Tabeie, Faraj; Nazarian, Hamid; Darbandi, Hasan; Amini, Abdoldllah; Mostafavinia, Ataroalsadat; Ghorishi, Seyed Kamran; Jalalifirouzkouhi, Ali; Bayat, Mohammad

    2016-09-01

    The purpose of this study was to evaluate the influences of helium-neon (He-Ne) and infrared (IR) lasers on the viability and proliferation rate of healthy and ovariectomy-induced osteoporotic (OVX) bone marrow mesenchymal stem cells (BMMSCs) in vitro. MSCs harvested from the BM of healthy and OVX rats were culture expanded. He-Ne and IR lasers were applied three times at energy densities of 0.6, 1.2, and 2.4 J/cm2 for BMMSCs. BMMSCs viability and proliferation rate were evaluated by MTT assay on days 2, 4, 6, 14, and 21. The results showed that healthy BMMSCs responded optimally to 0.6 J/cm2 using an IR laser after three times of laser radiation. Moreover, it was found that OVX-BMMSCs responded optimally to 0.6 J/cm2 with He-Ne laser and one-time laser radiation. It is concluded that the low-level laser therapy (LLLT) effect depends on the physiological state of the BMMSCs, type of the laser, wavelength, and number of laser sessions. The biostimulation efficiency of LLLT also depends on the delivered energy density. LLLT can enhance the viability and proliferation rate of healthy and especially osteoporotic autologous BMMSCs, which could be very useful in regenerative medicine.

  2. Mode selection laser

    DEFF Research Database (Denmark)

    2014-01-01

    spatial reflector variations, may be combined to generate a laser beam containing a plurality of orthogonal modes. The laser beam may be injected into a few- mode optical fiber, e.g. for the purpose of optical communication. The VCSEL may have intra-cavity contacts (31,37) and a Tunnel junction (33......) for current confinement into the active layer (34). An air-gap layer (102) may be provided between the upper reflector (15) and the SOI wafer (50) acting as a substrate. The lower reflector may be designed as a high-contrast grating (51) by etching....

  3. Student Perceived and Determined Knowledge of Biology Concepts in an Upper-Level Biology Course

    Science.gov (United States)

    Montplaisir, Lisa

    2014-01-01

    Students who lack metacognitive skills can struggle with the learning process. To be effective learners, students should recognize what they know and what they do not know. This study examines the relationship between students’ perception of their knowledge and determined knowledge in an upper-level biology course utilizing a pre/posttest approach. Significant differences in students’ perception of their knowledge and their determined knowledge exist at the beginning (pretest) and end (posttest) of the course. Alignment between student perception and determined knowledge was significantly more accurate on the posttest compared with the pretest. Students whose determined knowledge was in the upper quartile had significantly better alignment between their perception and determined knowledge on the pre- and posttest than students in the lower quartile. No difference exists between how students perceived their knowledge between upper- and lower-quartile students. There was a significant difference in alignment of perception and determined knowledge between males and females on the posttest, with females being more accurate in their perception of knowledge. This study provides evidence of discrepancies that exist between what students perceive they know and what they actually know. PMID:26086662

  4. Optical bistability in the oscillation of an inhomogeneously broadened quasi-three-level laser

    International Nuclear Information System (INIS)

    Liu, Junhai; Tian, Xueping

    2013-01-01

    A theoretical modeling analysis is presented to study the optical bistability exhibited in the oscillation of an inhomogeneously broadened quasi-three-level laser. All the major characteristics of optical bistability depend on two normalized parameters, f and x a , which are defined by f = I sat,a /I sat,m and x a = 2α a0 p a /δ and are related to measurable properties of the laser medium. In comparison with the case of a homogeneously broadened laser, the essential condition for the occurrence of such bistability, f a /(x a + 1), turns out to be the same, whereas the intensities at the up- and down-thresholds are substantially increased and the bistability range is reduced. (paper)

  5. Laser plant "Iguana" for transmyocardial revascularization based on kW-level waveguide CO2 laser

    Science.gov (United States)

    Panchenko, Vladislav Y.; Bockeria, L. A.; Berishvili, I. I.; Vasiltsov, Victor V.; Golubev, Vladimir S.; Ul'yanov, Valery A.

    2001-05-01

    For many years the Institute on Laser and Information Technologies RAN has been developing a concept of high-power industrial CO2 lasers with diffusion cooling of the working medium. The paper gives a description of the laser medical system Iguana for transmyocardial laser revascularization (TMLR) as an example of various applications of high-power waveguide CO2 lasers. The clinical results of the TMLR method application in surgical treatment are presented. The methods of determination of the time, when the laser beam passes through the demarcation line between myocardium tissue and blood, are discussed.

  6. Confocal Laser Endomicroscopy for the Diagnosis of Urothelial Carcinoma in the Bladder and the Upper Urinary Tract: Protocols for Two Prospective Explorative Studies.

    Science.gov (United States)

    Liem, Esmee Iml; Freund, Jan Erik; Baard, Joyce; de Bruin, D Martijn; Laguna Pes, M Pilar; Savci-Heijink, C Dilara; van Leeuwen, Ton G; de Reijke, Theo M; de la Rosette, Jean Jmch

    2018-02-07

    Visual confirmation of a suspicious lesion in the urinary tract is a major corner stone in diagnosing urothelial carcinoma. However, during cystoscopy (for bladder tumors) and ureterorenoscopy (for tumors of the upper urinary tract) no real-time histopathologic information can be obtained. Confocal laser endomicroscopy (CLE) is an optical imaging technique that allows for in vivo high-resolution imaging and may allow real-time tumor grading of urothelial lesions. The primary objective of both studies is to develop descriptive criteria for in vivo CLE images of urothelial carcinoma (low-grade, high-grade, carcinoma in situ) and normal urothelium by comparing CLE images with corresponding histopathology. In these two prospective clinical trials, CLE imaging will be performed of suspicious lesions and normal tissue in the urinary tract during surgery, prior to resection or biopsy. In the bladder study, CLE will be performed in 60 patients using the Cystoflex UHD-R probe. In the upper urinary tract study, CLE will be performed in 25 patients during ureterorenoscopy, who will undergo radical treatment (nephroureterectomy or segmental ureter resection) thereafter. All CLE images will be analyzed frame by frame by three independent, blinded observers. Histopathology and CLE-based diagnosis of the lesions will be evaluated. Both studies comply with the IDEAL stage 2b recommendations. Presently, recruitment of patients is ongoing in both studies. Results and outcomes are expected in 2018. For development of CLE-based diagnosis of urothelial carcinoma in the bladder and the upper urinary tract, a structured conduct of research is required. This study will provide more insight in tissue-specific CLE criteria for real-time tumor grading of urothelial carcinoma. Confocal Laser Endomicroscopy: ClinicalTrials.gov NCT03013894; https://clinicaltrials.gov /ct2/show/NCT03013894?term=NCT03013894&rank=1 (Archived by WebCite at http://www.webcitation.org/6wiPZ378I); and Dutch Central

  7. Effect of single-dose low-level helium-neon laser irradiation on orthodontic pain: a split-mouth single-blind placebo-controlled randomized clinical trial.

    Science.gov (United States)

    Sobouti, Farhad; Khatami, Maziar; Chiniforush, Nasim; Rakhshan, Vahid; Shariati, Mahsa

    2015-01-01

    Pain is the most common complication of orthodontic treatment. Low-level laser therapy (LLLT) has been suggested as a new analgesic treatment free of the adverse effects of analgesic medications. However, it is not studied thoroughly, and the available studies are quite controversial. Moreover, helium neon (He-Ne) laser has not been assessed before. This split-mouth placebo-controlled randomized clinical trial was performed on 16 male and 14 female orthodontic patients requiring bilateral upper canine retraction. The study was performed at a private clinic in Sari, Iran, in 2014. It was single blind: patients, orthodontist, and personnel were blinded of the allocations, but the laser operator (periodontist) was not blinded. Once canine retractor was activated, a randomly selected maxillary quarter received a single dose of He-Ne laser irradiation (632.8 nm, 10 mw, 6 j/cm(2) density). The other quarter served as the placebo side, treated by the same device but powered off. In the first, second, fourth, and seventh days, blinded patients rated their pain sensed on each side at home using visual analog scale (VAS) questionnaires. There was no harm identified during or after the study. Pain changes were analyzed using two- and one-way repeated-measures ANOVA, Bonferroni, and t-test (α = 0.01, β > 0.99). This trial was not registered. It was self-funded by the authors. Sixteen males and 11 females remained in the study (aged 12-21). Average pain scores sensed in all 4 intervals on control and laser sides were 4.06 ± 2.85 and 2.35 ± 1.77, respectively (t-test P < 0.0001). One-way ANOVA showed significant pain declines over time, in each group (P < 0.0001). Two-way ANOVA showed significant effects for LLLT (P < 0.0001) and time (P = <0.0001). Single-dose He-Ne laser therapy might reduce orthodontic pain caused by retracting maxillary canines.

  8. Highly efficient dual-wavelength mid-infrared CW Laser in diode end-pumped Er:SrF2 single crystals

    Science.gov (United States)

    Ma, Weiwei; Qian, Xiaobo; Wang, Jingya; Liu, Jingjing; Fan, Xiuwei; Liu, Jie; Su, Liangbi; Xu, Jun

    2016-11-01

    The spectral properties and laser performance of Er:SrF2 single crystals were investigated and compared with Er:CaF2. Er:SrF2 crystals have larger absorption cross-sections at the pumping wavelength, larger mid-infrared stimulated emission cross-sections and much longer fluorescence lifetimes of the upper laser level (Er3+:4I11/2 level) than those of Er:CaF2 crystals. Dual-wavelength continuous-wave (CW) lasers around 2.8 μm were demonstrated in both 4at.% and 10at.% Er:SrF2 single crystals under 972 nm laser diode (LD) end pumping. The laser wavelengths are 2789.3 nm and 2791.8 nm in the former, and 2786.4 nm and 2790.7 nm in the latter, respectively. The best laser performance has been demonstrated in lightly doped 4at.% Er:SrF2 with a low threshold of 0.100 W, a high slope efficiency of 22.0%, an maximum output power of 0.483 W.

  9. Low Upper Limit to Methane Abundance on Mars

    Science.gov (United States)

    Webster, Christopher R.; Mahaffy, Paul R.; Atreya, Sushil K.; Flesch, Gregory J.; Farley, Kenneth A.; Kemppinen, Osku; Bridges, Nathan; Johnson, Jeffrey R.; Minitti, Michelle; Cremers, David; Bell, James F.; Edgar, Lauren; Farmer, Jack; Godber, Austin; Wadhwa, Meenakshi; Wellington, Danika; McEwan, Ian; Newman, Claire; Richardson, Mark; Charpentier, Antoine; Peret, Laurent; King, Penelope; Blank, Jennifer; Weigle, Gerald; Schmidt, Mariek; Li, Shuai; Milliken, Ralph; Robertson, Kevin; Sun, Vivian; Baker, Michael; Edwards, Christopher; Ehlmann, Bethany; Farley, Kenneth; Griffes, Jennifer; Grotzinger, John; Miller, Hayden; Newcombe, Megan; Pilorget, Cedric; Rice, Melissa; Siebach, Kirsten; Stack, Katie; Stolper, Edward; Brunet, Claude; Hipkin, Victoria; Léveillé, Richard; Marchand, Geneviève; Sánchez, Pablo Sobrón; Favot, Laurent; Cody, George; Steele, Andrew; Flückiger, Lorenzo; Lees, David; Nefian, Ara; Martin, Mildred; Gailhanou, Marc; Westall, Frances; Israël, Guy; Agard, Christophe; Baroukh, Julien; Donny, Christophe; Gaboriaud, Alain; Guillemot, Philippe; Lafaille, Vivian; Lorigny, Eric; Paillet, Alexis; Pérez, René; Saccoccio, Muriel; Yana, Charles; Armiens-Aparicio, Carlos; Rodríguez, Javier Caride; Blázquez, Isaías Carrasco; Gómez, Felipe Gómez; Elvira, Javier Gómez; Hettrich, Sebastian; Malvitte, Alain Lepinette; Jiménez, Mercedes Marín; Martínez-Frías, Jesús; Soler, Javier Martín; Martín-Torres, F. Javier; Jurado, Antonio Molina; Mora-Sotomayor, Luis; Caro, Guillermo Muñoz; López, Sara Navarro; Peinado-González, Verónica; Pla-García, Jorge; Manfredi, José Antonio Rodriguez; Romeral-Planelló, Julio José; Fuentes, Sara Alejandra Sans; Martinez, Eduardo Sebastian; Redondo, Josefina Torres; Urqui-O'Callaghan, Roser; Mier, María-Paz Zorzano; Chipera, Steve; Lacour, Jean-Luc; Mauchien, Patrick; Sirven, Jean-Baptiste; Manning, Heidi; Fairén, Alberto; Hayes, Alexander; Joseph, Jonathan; Squyres, Steven; Sullivan, Robert; Thomas, Peter; Dupont, Audrey; Lundberg, Angela; Melikechi, Noureddine; Mezzacappa, Alissa; DeMarines, Julia; Grinspoon, David; Reitz, Günther; Prats, Benito; Atlaskin, Evgeny; Genzer, Maria; Harri, Ari-Matti; Haukka, Harri; Kahanpää, Henrik; Kauhanen, Janne; Kemppinen, Osku; Paton, Mark; Polkko, Jouni; Schmidt, Walter; Siili, Tero; Fabre, Cécile; Wray, James; Wilhelm, Mary Beth; Poitrasson, Franck; Patel, Kiran; Gorevan, Stephen; Indyk, Stephen; Paulsen, Gale; Gupta, Sanjeev; Bish, David; Schieber, Juergen; Gondet, Brigitte; Langevin, Yves; Geffroy, Claude; Baratoux, David; Berger, Gilles; Cros, Alain; d'Uston, Claude; Forni, Olivier; Gasnault, Olivier; Lasue, Jérémie; Lee, Qiu-Mei; Maurice, Sylvestre; Meslin, Pierre-Yves; Pallier, Etienne; Parot, Yann; Pinet, Patrick; Schröder, Susanne; Toplis, Mike; Lewin, Éric; Brunner, Will; Heydari, Ezat; Achilles, Cherie; Oehler, Dorothy; Sutter, Brad; Cabane, Michel; Coscia, David; Israël, Guy; Szopa, Cyril; Dromart, Gilles; Robert, François; Sautter, Violaine; Le Mouélic, Stéphane; Mangold, Nicolas; Nachon, Marion; Buch, Arnaud; Stalport, Fabien; Coll, Patrice; François, Pascaline; Raulin, François; Teinturier, Samuel; Cameron, James; Clegg, Sam; Cousin, Agnès; DeLapp, Dorothea; Dingler, Robert; Jackson, Ryan Steele; Johnstone, Stephen; Lanza, Nina; Little, Cynthia; Nelson, Tony; Wiens, Roger C.; Williams, Richard B.; Jones, Andrea; Kirkland, Laurel; Treiman, Allan; Baker, Burt; Cantor, Bruce; Caplinger, Michael; Davis, Scott; Duston, Brian; Edgett, Kenneth; Fay, Donald; Hardgrove, Craig; Harker, David; Herrera, Paul; Jensen, Elsa; Kennedy, Megan R.; Krezoski, Gillian; Krysak, Daniel; Lipkaman, Leslie; Malin, Michael; McCartney, Elaina; McNair, Sean; Nixon, Brian; Posiolova, Liliya; Ravine, Michael; Salamon, Andrew; Saper, Lee; Stoiber, Kevin; Supulver, Kimberley; Van Beek, Jason; Van Beek, Tessa; Zimdar, Robert; French, Katherine Louise; Iagnemma, Karl; Miller, Kristen; Summons, Roger; Goesmann, Fred; Goetz, Walter; Hviid, Stubbe; Johnson, Micah; Lefavor, Matthew; Lyness, Eric; Breves, Elly; Dyar, M. Darby; Fassett, Caleb; Blake, David F.; Bristow, Thomas; DesMarais, David; Edwards, Laurence; Haberle, Robert; Hoehler, Tori; Hollingsworth, Jeff; Kahre, Melinda; Keely, Leslie; McKay, Christopher; Wilhelm, Mary Beth; Bleacher, Lora; Brinckerhoff, William; Choi, David; Conrad, Pamela; Dworkin, Jason P.; Eigenbrode, Jennifer; Floyd, Melissa; Freissinet, Caroline; Garvin, James; Glavin, Daniel; Harpold, Daniel; Jones, Andrea; Mahaffy, Paul; Martin, David K.; McAdam, Amy; Pavlov, Alexander; Raaen, Eric; Smith, Michael D.; Stern, Jennifer; Tan, Florence; Trainer, Melissa; Meyer, Michael; Posner, Arik; Voytek, Mary; Anderson, Robert C.; Aubrey, Andrew; Beegle, Luther W.; Behar, Alberto; Blaney, Diana; Brinza, David; Calef, Fred; Christensen, Lance; Crisp, Joy A.; DeFlores, Lauren; Ehlmann, Bethany; Feldman, Jason; Feldman, Sabrina; Flesch, Gregory; Hurowitz, Joel; Jun, Insoo; Keymeulen, Didier; Maki, Justin; Mischna, Michael; Morookian, John Michael; Parker, Timothy; Pavri, Betina; Schoppers, Marcel; Sengstacken, Aaron; Simmonds, John J.; Spanovich, Nicole; Juarez, Manuel de la Torre; Vasavada, Ashwin R.; Webster, Christopher R.; Yen, Albert; Archer, Paul Douglas; Cucinotta, Francis; Jones, John H.; Ming, Douglas; Morris, Richard V.; Niles, Paul; Rampe, Elizabeth; Nolan, Thomas; Fisk, Martin; Radziemski, Leon; Barraclough, Bruce; Bender, Steve; Berman, Daniel; Dobrea, Eldar Noe; Tokar, Robert; Vaniman, David; Williams, Rebecca M. E.; Yingst, Aileen; Lewis, Kevin; Leshin, Laurie; Cleghorn, Timothy; Huntress, Wesley; Manhès, Gérard; Hudgins, Judy; Olson, Timothy; Stewart, Noel; Sarrazin, Philippe; Grant, John; Vicenzi, Edward; Wilson, Sharon A.; Bullock, Mark; Ehresmann, Bent; Hamilton, Victoria; Hassler, Donald; Peterson, Joseph; Rafkin, Scot; Zeitlin, Cary; Fedosov, Fedor; Golovin, Dmitry; Karpushkina, Natalya; Kozyrev, Alexander; Litvak, Maxim; Malakhov, Alexey; Mitrofanov, Igor; Mokrousov, Maxim; Nikiforov, Sergey; Prokhorov, Vasily; Sanin, Anton; Tretyakov, Vladislav; Varenikov, Alexey; Vostrukhin, Andrey; Kuzmin, Ruslan; Clark, Benton; Wolff, Michael; McLennan, Scott; Botta, Oliver; Drake, Darrell; Bean, Keri; Lemmon, Mark; Schwenzer, Susanne P.; Anderson, Ryan B.; Herkenhoff, Kenneth; Lee, Ella Mae; Sucharski, Robert; Hernández, Miguel Ángel de Pablo; Ávalos, Juan José Blanco; Ramos, Miguel; Kim, Myung-Hee; Malespin, Charles; Plante, Ianik; Muller, Jan-Peter; Navarro-González, Rafael; Ewing, Ryan; Boynton, William; Downs, Robert; Fitzgibbon, Mike; Harshman, Karl; Morrison, Shaunna; Dietrich, William; Kortmann, Onno; Palucis, Marisa; Sumner, Dawn Y.; Williams, Amy; Lugmair, Günter; Wilson, Michael A.; Rubin, David; Jakosky, Bruce; Balic-Zunic, Tonci; Frydenvang, Jens; Jensen, Jaqueline Kløvgaard; Kinch, Kjartan; Koefoed, Asmus; Madsen, Morten Bo; Stipp, Susan Louise Svane; Boyd, Nick; Campbell, John L.; Gellert, Ralf; Perrett, Glynis; Pradler, Irina; VanBommel, Scott; Jacob, Samantha; Owen, Tobias; Rowland, Scott; Atlaskin, Evgeny; Savijärvi, Hannu; Boehm, Eckart; Böttcher, Stephan; Burmeister, Sönke; Guo, Jingnan; Köhler, Jan; García, César Martín; Mueller-Mellin, Reinhold; Wimmer-Schweingruber, Robert; Bridges, John C.; McConnochie, Timothy; Benna, Mehdi; Franz, Heather; Bower, Hannah; Brunner, Anna; Blau, Hannah; Boucher, Thomas; Carmosino, Marco; Atreya, Sushil; Elliott, Harvey; Halleaux, Douglas; Rennó, Nilton; Wong, Michael; Pepin, Robert; Elliott, Beverley; Spray, John; Thompson, Lucy; Gordon, Suzanne; Newsom, Horton; Ollila, Ann; Williams, Joshua; Vasconcelos, Paulo; Bentz, Jennifer; Nealson, Kenneth; Popa, Radu; Kah, Linda C.; Moersch, Jeffrey; Tate, Christopher; Day, Mackenzie; Kocurek, Gary; Hallet, Bernard; Sletten, Ronald; Francis, Raymond; McCullough, Emily; Cloutis, Ed; ten Kate, Inge Loes; Kuzmin, Ruslan; Arvidson, Raymond; Fraeman, Abigail; Scholes, Daniel; Slavney, Susan; Stein, Thomas; Ward, Jennifer; Berger, Jeffrey; Moores, John E.

    2013-10-01

    By analogy with Earth, methane in the Martian atmosphere is a potential signature of ongoing or past biological activity. During the past decade, Earth-based telescopic observations reported “plumes” of methane of tens of parts per billion by volume (ppbv), and those from Mars orbit showed localized patches, prompting speculation of sources from subsurface bacteria or nonbiological sources. From in situ measurements made with the Tunable Laser Spectrometer (TLS) on Curiosity using a distinctive spectral pattern specific to methane, we report no detection of atmospheric methane with a measured value of 0.18 ± 0.67 ppbv corresponding to an upper limit of only 1.3 ppbv (95% confidence level), which reduces the probability of current methanogenic microbial activity on Mars and limits the recent contribution from extraplanetary and geologic sources.

  10. High-level PC-based laser system modeling

    Science.gov (United States)

    Taylor, Michael S.

    1991-05-01

    Since the inception of the Strategic Defense Initiative (SDI) there have been a multitude of comparison studies done in an attempt to evaluate the effectiveness and relative sizes of complementary, and sometimes competitive, laser weapon systems. It became more and more apparent that what the systems analyst needed was not only a fast, but a cost effective way to perform high-level trade studies. In the present investigation, a general procedure is presented for the development of PC-based algorithmic systems models for laser systems. This procedure points out all of the major issues that should be addressed in the design and development of such a model. Issues addressed include defining the problem to be modeled, defining a strategy for development, and finally, effective use of the model once developed. Being a general procedure, it will allow a systems analyst to develop a model to meet specific needs. To illustrate this method of model development, a description of the Strategic Defense Simulation - Design To (SDS-DT) model developed and used by Science Applications International Corporation (SAIC) is presented. SDS-DT is a menu-driven, fast executing, PC-based program that can be used to either calculate performance, weight, volume, and cost values for a particular design or, alternatively, to run parametrics on particular system parameters to perhaps optimize a design.

  11. Low-level laser therapy to treat fibromyalgia.

    Science.gov (United States)

    Ruaro, J A; Fréz, A R; Ruaro, M B; Nicolau, R A

    2014-11-01

    Several clinical treatments have been proposed to manage symptoms of fibromyalgia. Low-level laser therapy (LLLT) may be a useful tool to treat this dysfunction. The aim of this study was to evaluate the effects of LLLT in patients with fibromyalgia. A placebo-controlled, randomized clinical trial was carried out with 20 patients divided randomly into either an LLLT group (n = 10) or a placebo group (n = 10). The LLLT group was treated with a GaAlAs laser (670 nm, 4 J/cm(2) on 18 tender points) three times a week over 4 weeks. Before and after treatment, patients were evaluated with the Fibromyalgia Impact Questionnaire (FIQ), McGill Pain Questionnaire, and visual analog scale (VAS). Data from the FIQ and McGill questionnaire for the treated and control groups were analyzed by paired t tests, and Wilcoxon tests were used to analyze data from the VAS. After LLLT or sham treatment, the number of tender points was significantly reduced in both groups (LLLT, p fibromyalgia symptoms showed significant improvements after LLLT compared to placebo (FIQ, p = 0.0003; McGill, p = 0.0078; and VAS, p = 0.0020). LLLT provided relief from fibromyalgia symptoms in patients and should be further investigated as a therapeutic tool for management in fibromyalgia.

  12. The Advanced Labs Website: resources for upper-level laboratories

    Science.gov (United States)

    Torres-Isea, Ramon

    2012-03-01

    The Advanced Labs web resource collection is an effort to create a central, comprehensive information base for college/university faculty who teach upper-level undergraduate laboratories. The website is produced by the American Association of Physics Teachers (AAPT). It is a part of ComPADRE, the online collection of resources in physics and astronomy education, which itself is a part of the National Science Foundation-funded National Science Digital Library (NSDL). After a brief review of its history, we will discuss the current status of the website while describing the various types of resources available at the site and presenting examples of each. We will detail a step-by-step procedure for submitting resources to the website. The resource collection is designed to be a community effort and thus welcomes input and contributions from its users. We will also present plans, and will seek audience feedback, for additional website services and features. The constraints, roadblocks, and rewards of this project will also be addressed.

  13. Room Temperature Erbium-Doped Yttrium Vanadate (Er:YVO4) Laser and Amplifier

    Science.gov (United States)

    2016-09-01

    10%. We maintained the LDM pump pulse duration at 5 ms, which is much longer than the Er3+ upper laser level (4I13/2) lifetime in YVO4 at RT (3 ms...of 2 ms ranging from 4 to 131 W was used to invert the gain medium. At 1.8 ms into the pump pulse, the 1603-nm seed was turned on for 500 µs. As

  14. Effect of Low-Level Laser Stimulation on EEG Power in Normal Subjects with Closed Eyes

    Directory of Open Access Journals (Sweden)

    Jih-Huah Wu

    2013-01-01

    Full Text Available In a previous study, we found that the low-level laser (LLL stimulation at the palm with a frequency of 10 Hz was able to induce significant brain activation in normal subjects with opened eyes. However, the electroencephalography (EEG changes to LLL stimulation in subjects with closed eyes have not been studied. In the present study, the laser array stimulator was applied to deliver insensible laser stimulations to the palm of the tested subjects with closed eyes (the laser group. The EEG activities before, during, and after the laser stimulation were collected. The EEG amplitude powers of each EEG frequency band at 19 locations were calculated. These power data were then analyzed by SPSS software using repeated-measure ANOVAs and appropriate posthoc tests. We found a pronounced decrease in the EEG power in alpha-bandwidth during laser simulation and then less decrease in the EEG power in delta-bandwidth in normal subjects with laser stimulation. The EEG power in beta-bandwidth in the right occipital area also decreased significantly in the laser group. We suggest that LLL stimulation might be conducive to falling into sleep in patients with sleep problems.

  15. Three-dimensional motion tracking correlates with skill level in upper gastrointestinal endoscopy

    DEFF Research Database (Denmark)

    Arnold, Sif H.; Svendsen, Morten Bo Søndergaard; Konge, Lars

    2015-01-01

    untrained medical students) were tested using a virtual reality simulator. A motion sensor was used to collect data regarding the distance between the hands, and height and movement of the scope hand. Test characteristics between groups were explored using Kruskal-Wallis H and Man-Whitney U exact tests......Background and study aim: Feedback is an essential part of training in upper gastrointestinal endoscopy. Virtual reality simulators provide limited feedback, focusing only on visual recognition with no feedback on the procedural part of training. Motion tracking identifies patterns of movement......, and this study aimed to explore the correlation between skill level and operator movement using an objective automated tool. Methods: In this medical education study, 37 operators (12 senior doctors who performed endoscopic retrograde cholangiopancreatography, 13 doctors with varying levels of experience, and 12...

  16. Sensitive Multi-Species Emissions Monitoring: Infrared Laser-Based Detection of Trace-Level Contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Steill, Jeffrey D. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Huang, Haifeng [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Hoops, Alexandra A. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Patterson, Brian D. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Birtola, Salvatore R. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Jaska, Mark [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Strecker, Kevin E. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Chandler, David W. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Bisson, Soott [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2014-09-01

    This report summarizes our development of spectroscopic chemical analysis techniques and spectral modeling for trace-gas measurements of highly-regulated low-concentration species present in flue gas emissions from utility coal boilers such as HCl under conditions of high humidity. Detailed spectral modeling of the spectroscopy of HCl and other important combustion and atmospheric species such as H 2 O, CO 2 , N 2 O, NO 2 , SO 2 , and CH 4 demonstrates that IR-laser spectroscopy is a sensitive multi-component analysis strategy. Experimental measurements from techniques based on IR laser spectroscopy are presented that demonstrate sub-ppm sensitivity levels to these species. Photoacoustic infrared spectroscopy is used to detect and quantify HCl at ppm levels with extremely high signal-to-noise even under conditions of high relative humidity. Additionally, cavity ring-down IR spectroscopy is used to achieve an extremely high sensitivity to combustion trace gases in this spectral region; ppm level CH 4 is one demonstrated example. The importance of spectral resolution in the sensitivity of a trace-gas measurement is examined by spectral modeling in the mid- and near-IR, and efforts to improve measurement resolution through novel instrument development are described. While previous project reports focused on benefits and complexities of the dual-etalon cavity ring-down infrared spectrometer, here details on steps taken to implement this unique and potentially revolutionary instrument are described. This report also illustrates and critiques the general strategy of IR- laser photodetection of trace gases leading to the conclusion that mid-IR laser spectroscopy techniques provide a promising basis for further instrument development and implementation that will enable cost-effective sensitive detection of multiple key contaminant species simultaneously.

  17. Fiber fuse behavior in kW-level continuous-wave double-clad field laser

    International Nuclear Information System (INIS)

    Sun Jun-Yi; Xiao Qi-Rong; Li Dan; Wang Xue-Jiao; Zhang Hai-Tao; Gong Ma-Li; Yan Ping

    2016-01-01

    In this study, original experimental data for fiber fuse in kW-level continuous-wave (CW) high power double-clad fiber (DCF) laser are reported. The propagating velocity of the fuse is 9.68 m/s in a 3.1-kW Yb-doped DCF laser. Three other cases in Yb-doped DCF are also observed. We think that the ignition of fiber fuse is caused by thermal mechanism, and the formation of bullet-shaped tracks is attributed to the optical discharge and temperature gradient. The inducements of initial fuse and formation of bullet-shaped voids are analyzed. This investigation of fiber fuse helps better understand the fiber fuse behavior, in order to avoid the catastrophic destruction caused by fiber fuse in high power fiber laser. (paper)

  18. Expression of DMP-1 in the human pulp tissue using low level laser therapy

    International Nuclear Information System (INIS)

    Neto, Natalino Lourenço; Teixeira Marques, Nádia Carolina; Fernandes, Ana Paula; Silva, Thiago Cruvinel; Andrade Moreira Machado, Maria Aparecida; Oliveira, Thais Marchini; Rodini, Camila Oliveira

    2015-01-01

    This study aimed to evaluate the effects of low-level laser therapy (LLLT) on DMP-1 expression in pulp tissue repair of human primary teeth. Twenty mandibular primary molars were randomly assigned into the following groups: Group I—Buckley’s Formocresol (FC); Group II—Calcium Hydroxide (CH); Group III—LLLT + CH and Group IV—LLLT + Zinc oxide/Eugenol. The teeth at the regular exfoliation period were extracted for histological analysis and immunolocalization of DMP-1. Descriptive analysis was performed on the dentin pulp complex. Histopathological assessment showed internal resorption in group FC. Groups CH and LLLT + CH provided better pulpal repair due to the absence of inflammation and the formation of hard tissue barrier. These two groups presented odontoblastic layer expressing DMP-1. According to this study, low level laser therapy preceding the use of calcium hydroxide exhibited satisfactory bio-inductive activity on pulp tissue repair of human primary teeth. However, other histological and cellular studies are needed to confirm the laser tissue action and efficacy. (paper)

  19. The Relationship Between Air Particulate Levels and Upper Respiratory Disease in Soldiers Deployed to Bosnia (1997-1998)

    National Research Council Canada - National Science Library

    Hastings, Deborah

    2001-01-01

    This study had three objectives: to determine if there is a relationship between air particulate levels and upper respiratory disease in soldiers deployed to Bosnia between 1997-98, to establish a method for linking environmental...

  20. Propagation of frequency-chirped laser pulses in a medium of atoms with a Λ-level scheme

    International Nuclear Information System (INIS)

    Demeter, G.; Dzsotjan, D.; Djotyan, G. P.

    2007-01-01

    We study the propagation of frequency-chirped laser pulses in optically thick media. We consider a medium of atoms with a Λ level-scheme (Lambda atoms) and also, for comparison, a medium of two-level atoms. Frequency-chirped laser pulses that induce adiabatic population transfer between the atomic levels are considered. They induce transitions between the two lower (metastable) levels of the Λ-atoms and between the ground and excited states of the two-level atoms. We show that associated with this adiabatic population transfer in Λ-atoms, there is a regime of enhanced transparency of the medium--the pulses are distorted much less than in the medium of two-level atoms and retain their ability to transfer the atomic population much longer during propagation

  1. Analysis of Pulsed Laser Welding Parameters Effect on Weld Geometry of 316L Stainless Steel using DOE

    Directory of Open Access Journals (Sweden)

    M. R. Pakmanesh

    2018-03-01

    Full Text Available In the present study, the optimization of pulsed Nd:YAG laser welding parameters was done on a lap-joint of a 316L stainless steel foil in order to predict the weld geometry through response surface methodology. For this purpose, the effects of laser power, pulse duration, and frequency were investigated. By presenting a second-order polynomial, the above-mentioned statistical method was managed to be well employed to evaluate the effect of welding parameters on weld width. The results showed that the weld width at the upper, middle and lower surfaces of weld cross section increases by increasing pulse durationand laser power; however, the effects of these parameters on the mentioned levels are different. The effect of pulse duration in the models of weld upper, middle and lower widths was calculated as 76, 73 and 68%, respectively. Moreover, the effect of power on theses widths was determined as 18, 24 and 28%, respectively. Finally, by superimposing these models, optimum conditions were obtained to attain a full penetration weld and the weld with no defects.

  2. Successful Treatment of Resistant Discoid Lupus Erythematous (DLE With Low-Level Laser Therapy (LLLT: A Case Report

    Directory of Open Access Journals (Sweden)

    Nooshafarin Kazemikhoo

    2015-12-01

    Full Text Available Introduction Lupus is a chronic autoimmune illness characterized by production of autoantibodies against nuclear antigens. Lupus may also only appear as a skin disease. Discoid lupus erythematous (DLE, the most common form of chronic cutaneous lupus erythematous is characterized by patches of persistent erythema, adherent scaling, follicular plugging and, in the later stages scaring and atrophy. Case Presentation The case was a 33-year-old female with two years history of DLE, who referred to the laser clinic of Milad hospital with acute flare of skin lesions since seven months ego. She had four lesions (three with local alopecia, scaling and itching and one with atrophy. Serological studies for antinuclear antibodies and anti Ro/SS-A antibody were negative. After five sessions of treatment with infrared (830 nm; 200 mw and red light (630 nm; 20 mw diode laser in addition to intravenous red light laser (655 nm; 2 mw for 20 minutes and laser acupuncture with infrared diode laser (1 J/cm2 for six acupuncture points every other day, the beneficial effects started to appear, and after nine sessions, local itching of the lesions had stopped. Through a total of 27 sessions of treatment, the lesions improved completely with highly satisfactory results; and drug-therapy held to be continued. No disease flare up was seen after the one-year follow up. Conclusions To the best of our knowledge, this is the first case report on low-level laser therapy (LLLT treatment of DLE. Low-level laser therapy may be effective in treating inflammatory lesions such as cutaneous lesions of discoid lupus erythematous. More studies with higher sample size are needed to clarify the role of low level lasers in treating such lesions.

  3. Role of upper-level wind shear on the structure and maintenance of derecho-producing convective systems

    Science.gov (United States)

    Coniglio, Michael Charles

    Common large-scale environments associated with the development of derecho-producing convective systems from a large number of events are identified using statistical clustering of the 500-mb geopotential heights as guidance. The majority of the events (72%) fall into three main patterns that include a well-defined upstream trough (40%), a ridge (20%), and a zonal, low-amplitude flow (12%), which is defined as an additional warm-season pattern that is not identified in past studies of derecho environments. Through an analysis of proximity soundings, discrepancies are found in both low-level and deep-tropospheric shear parameters between observations and the shear profiles considered favorable for strong, long-lived convective systems in idealized simulations. To explore the role of upper-level shear in derecho environments, a set of two-dimensional simulations of density currents within a dry, neutrally stable environment are used to examine the ability of a cold pool to lift environmental air within a vertically sheared flow. The results confirm that the addition of upper-level shear to a wind profile with weak to moderate low-level shear increases the vertical displacement of low-level parcels despite a decrease in the vertical velocity along the cold pool interface, as suggested by previous studies. Parcels that are elevated above the surface (1-2 km) overturn and are responsible for the deep lifting in the deep-shear environments. This deep overturning caused by the upper-level shear helps to maintain the tilt of the convective systems in more complex two-dimensional and three dimensional simulations. The overturning also is shown to greatly increase the size of the convective systems in the three-dimensional simulations by facilitating the initiation and maintenance of convective cells along the cold pool. When combined with estimates of the cold pool motion and the storm-relative hodograph, these results may best be used for the prediction of the demise of

  4. Experimental verification of the imposing principle for maximum permissible levels of multicolor laser radiation

    Directory of Open Access Journals (Sweden)

    Ivashin V.A.

    2013-12-01

    Full Text Available Aims. The study presents the results of experimental research to verify the principle overlay for maximum permissible levels (MPL of multicolor laser radiation single exposure on eyes. This principle of the independence of the effects of radiation with each wavelength (the imposing principle, was founded and generalized to a wide range of exposure conditions. Experimental verification of this approach in relation to the impact of laser radiation on tissue fundus of an eye, as shows the analysis of the literature was not carried out. Material and methods. Was used in the experimental laser generating radiation with wavelengths: Л1 =0,532 microns, A2=0,556to 0,562 microns and A3=0,619to 0,621 urn. Experiments were carried out on eyes of rabbits with evenly pigmented eye bottom. Results. At comparison of results of processing of the experimental data with the calculated data it is shown that these levels are close by their parameters. Conclusions. For the first time in the Russian Federation had been performed experimental studies on the validity of multi-colored laser radiation on the organ of vision. In view of the objective coincidence of the experimental data with the calculated data, we can conclude that the mathematical formulas work.

  5. Personality Type and Student Performance in Upper-Level Economics Courses: The Importance of Race and Gender.

    Science.gov (United States)

    Borg, Mary O.; Stranahan, Harriet A.

    2002-01-01

    Demonstrates that personality type is an important explanatory variable in student performance in upper level economics courses. Finds that certain personality types, combined with race and gender effects, produce students who outperform other students. Introverts and those with the Keirsey-Bates temperament combination of sensing/judging…

  6. Biostimulation effect of low-level laser on healing process after third molar surgery, based on biochemical markers in saliva

    Science.gov (United States)

    Kroulikova, Veronika; Dostálová, Tatjana; Podzimek, Stepan

    2015-02-01

    Third molar extractions in general anesthesia have become a standard procedure in dentistry. There is an effort to shorten healing time and decrease the number of complications as well as increase comfort after the treatment. Low-level lasers are known for their analgesic, anti-inflammatory, and stimulatory effect. The aim of the study is to evaluate the effect of low-level laser after surgery in general anesthesia reducing the patient's discomfort, i.e. mainly pain, and also, to monitor the biostimulation process. Our study included 79 patients treated at the Department of Maxilofacial Surgery, diagnosed with third molar retention. Diode low-level laser radiation (wavelength 830 nm, output power 270 mW, probe aperture of 6.4 mm2) with dose ~ 3 mJ was applied. The control group was treated by using placebo - red light. The exposure time was 11 seconds immediately after the suture; the treatment was repeated every day for the following 3 days. To evaluate the effect of laser biostimulation, the objective markers for immunological determination of healing - sIgA and lysozyme in non-stimulated saliva of patients - were used. The sIgA decreases after laser application from 546.91 mg/l to 304. 91mg/l and in the control group from 602.25mg/l to 425.62 mg/l. The results were statistically significant. The level of lysozyme decreases from 54.27 mg/l to 2.45mg/l after laser biostimulation, from 304.371mg/l to 11.08mg/l after placebo effect. The study has confirmed a low-level laser healing effect not directly related to pain.

  7. Optical spectroscopy of rubidium Rydberg atoms with a 297 nm frequency doubled dye laser

    International Nuclear Information System (INIS)

    Becker, Th.; Germann, Th.; Thoumany, P.; Stania, G.; Urbonas, L.; Haensch, T.

    2008-01-01

    Full text: Rydberg atoms have played an important role in atomic physics and optical spectroscopy since many years. Due to their long lifetime and the big dipole matrix element between neighbouring Rydberg levels they are an essential tool in microwave cavity-qed experiments. Ultracold Rydberg gases are a promising candidate for realizing controlled quantum gates in atomic ensembles. In most experiments Rydberg atoms are detected destructively, where the optically excited atoms are first ionized followed by an electronic detection of the ionization products. A Doppler-free purely optical detection was reported in a room temperature cell and in an atomic beam apparatus using the technique of electromagnetically induced transparency. In all these experiments the Rydberg atoms are excited with two lasers in a two-step ladder configuration. Here we show that Doppler-free purely optical spectroscopy is also possible with a one step excitation scheme involving a UV laser at 297 nm. We excite the 85 Rb isotope from the 5S 1/2 ground state to the 63P 3/2 state with a frequency doubled dye laser in a room temperature gas cell without buffer gas. Rydberg transitions are detected by monitoring the absorption of 780 nm laser light which is superimposed on the UV light and resonant with one hyperfine component of the Rubidium D2 line. With these two lasers we realize a V-scheme and utilize the quantum amplification effect due to the different natural lifetimes of the upper levels of the two transitions: an excitation into the 63P level hinders many absorption-emission cycles of the D2 transition and leads to a reduced absorption on that line. We discuss the shape of the observed spectra in the context of electron shelving and EIT experiments. By applying a frequency modulation to the UV laser, we can obtain dispersive signals which can be used to stabilize the laser to a specific Rydberg transition. By shifting the frequency of the 780 nm laser to crossover resonances in the

  8. Theoretical investigation of output features of a diode-pumped rubidium vapor laser

    Science.gov (United States)

    Wang, You; Cai, He; Zhang, Wei; Xue, Liangping; Wang, Hongyuan; Han, Juhong

    2014-02-01

    In the recent years, diode-pumped alkali lasers (DPALs) have been paid many attentions because of their excellent performances. In fact, the characteristics of a DPAL strongly depend on the physical features of buffer gases. In this report, we selected a diode-pumped rubidium vapor laser (DPRVL), which is an important type among three common DPALs, to investigate how the characteristics of a DPRVL are affected by different conditions. The results signify that the population ratio of two excitation energy-levels are close to that corresponding to thermal equilibrium as the pressure of buffer gases and the temperature of a vapor cell become higher. It has been found that quenching of the upper levels cannot be simply ignored especially for the case of weak pump. The conclusions are thought to be helpful for the configuration design of an end-pumped DPAL.

  9. Teaching Introductory Upper-Level Religion and Theology Classes

    Science.gov (United States)

    Clingerman, Forrest; O'Brien, Kevin J.

    2015-01-01

    The undergraduate study of religion is predominantly undertaken by non-majors who are meeting a general education requirement. This means that, while curricular discussions make important distinctions between the work of lower- and upper-division courses, many religion and theology faculty are teaching hybrid courses that we call…

  10. Low-level laser therapy with 940 nm diode laser on stability of dental implants: a randomized controlled clinical trial.

    Science.gov (United States)

    Torkzaban, Parviz; Kasraei, Shahin; Torabi, Sara; Farhadian, Maryam

    2018-02-01

    Low-level laser therapy (LLLT) is a non-invasive modality to promote osteoblastic activity and tissue healing. The aim of this study was to evaluate the efficacy of LLLT for improvement of dental implant stability. This randomized controlled clinical trial was performed on 80 dental implants placed in 19 patients. Implants were randomly divided into two groups (n = 40). Seven sessions of LLLT (940 nm diode laser) were scheduled for the test group implants during 2 weeks. Laser was irradiated to the buccal and palatal sides. The same procedure was performed for the control group implants with laser hand piece in "off" mode. Implant stability was measured by Osstell Mentor device in implant stability quotient (ISQ) value immediately after surgery and 10 days and 3, 6, and 12 weeks later. Repeated measures ANOVA was used to compare the mean ISQ values (implant stability) in the test and control groups. Statistical test revealed no significant difference in the mean values of implant stability between the test and control groups over time (P = 0.557). Although the mean values of implant stability changed significantly in both groups over time (P laser group in the first weeks and increased from the 6th to 12th week, LLLT had no significant effect on dental implant stability.

  11. Student Perceived and Determined Knowledge of Biology Concepts in an Upper-Level Biology Course

    OpenAIRE

    Ziegler, Brittany; Montplaisir, Lisa

    2014-01-01

    Students who lack metacognitive skills can struggle with the learning process. To be effective learners, students should recognize what they know and what they do not know. This study examines the relationship between students’ perception of their knowledge and determined knowledge in an upper-level biology course utilizing a pre/posttest approach. Significant differences in students’ perception of their knowledge and their determined knowledge exist at the beginning (pretest) and end (postte...

  12. Education Pays Off! On Transition to Work for 25 Year Olds in Norway with Upper Secondary Education or Lower as Their Highest Educational Level

    Science.gov (United States)

    Markussen, Eifred

    2017-01-01

    In this article we examine the relationship between educational level and position in the labour market at age 25 for those who have completed upper secondary education or lower as their highest educational level. Whilst completion of upper secondary education is widely regarded as being important, we find that early and lasting work experience…

  13. High performance 5.6μm quantum cascade lasers

    Science.gov (United States)

    Suttinger, M.; Go, R.; Figueiredo, P.; Todi, A.; Shu, Hong; Lyakh, A.

    2017-02-01

    5.6 μm quantum cascade lasers based on Al 0.78 In 0.22 As/In 0.69 Ga 0.31 As active region composition with measured pulsed room temperature wall plug efficiency of 28.3% are reported. Injection efficiency for the upper laser level of 75% was measured for the new design by testing devices with variable cavity length. Threshold current density of 1.7kA/cm2 and slope efficiency of 4.9W/A were measured for uncoated 3.15mm × 9μm lasers. Threshold current density and slope efficiency dependence on temperature in the range from 288K to 348K for the new structure can be described by characteristic temperatures T0 140K and T1 710K, respectively. Experimental data for inverse slope efficiency dependence on cavity length for 15-stage quantum cascade lasers with the same design are also presented. When combined with the 40-stage device data, the new data allowed for separate evaluation of the losses originating from the active region and from the cladding layers of the laser structure. Specifically, the active region losses for the studied design were found to be 0.77 cm-1, while cladding region losses - 0.33 cm-1. The data demonstrate that active region losses in mid wave infrared quantum cascade lasers largely define total waveguide losses and that their reduction should be one of the main priorities in the quantum cascade laser design.

  14. kW-level commercial Yb-doped aluminophosphosilicate ternary laser fiber

    Science.gov (United States)

    Sun, Shihao; Zhan, Huan; Li, Yuwei; Liu, Shuang; Jiang, Jiali; Peng, Kun; Wang, Yuying; Ni, Li; Wang, Xiaolong; Jiang, Lei; Yu, Juan; Liu, Gang; Lu, Pengfei; Wang, Jianjun; Jing, Feng; Lin, Aoxiang

    2018-03-01

    Based on a master oscillator power amplifier configuration, laser performance of commercial Nufern-20/400-8M Ybdoped aluminophosphosilicate ternary laser fiber was investigated. Pumped by 976 nm laser diodes, 982 W laser output power was obtained with a slope efficiency of 84.9%. Spectrum of output was centered at 1066.56nm with 3dB bandwidth less than 0.32 nm, and the nonlinearity suppression ratio was more than 39dB. Beam quality of Mx2 and M2y were 1.55 and 1.75 at 982 W, respectively. The laser performance indicated that Nufern-20/400-8M Yb-doped aluminophosphosilicate ternary laser fiber is highly competitive for industry fiber laser use.

  15. Proposal of laser-driven automobile

    Science.gov (United States)

    Yabe, Takashi; Oozono, Hirokazu; Taniguchi, Kazumoto; Ohkubo, Tomomasa; Miyazaki, Sho; Uchida, Shigeaki; Baasandash, Choijil

    2004-09-01

    We propose an automobile driven by piston motion, which is driven by water-laser coupling. The automobile can load a solar-pumped fiber laser or can be driven by ground-based lasers. The vehicle is much useful for the use in other planet in which usual combustion engine cannot be used. The piston is in a closed system and then the water will not be exhausted into vacuum. In the preliminary experiment, we succeeded to drive the cylindrical piston of 0.2g (6mm in diameter) on top of water placed inside the acrylic pipe of 8 mm in inner diameter and the laser is incident from the bottom and focused onto the upper part of water by the lens (f=8mm) attached to the bottom edge.

  16. Nuclear and Particle Physics Simulations: The Consortium of Upper-Level Physics Software

    Science.gov (United States)

    Bigelow, Roberta; Moloney, Michael J.; Philpott, John; Rothberg, Joseph

    1995-06-01

    The Consortium for Upper Level Physics Software (CUPS) has developed a comprehensive series of Nine Book/Software packages that Wiley will publish in FY `95 and `96. CUPS is an international group of 27 physicists, all with extensive backgrounds in the research, teaching, and development of instructional software. The project is being supported by the National Science Foundation (PHY-9014548), and it has received other support from the IBM Corp., Apple Computer Corp., and George Mason University. The Simulations being developed are: Astrophysics, Classical Mechanics, Electricity & Magnetism, Modern Physics, Nuclear and Particle Physics, Quantum Mechanics, Solid State, Thermal and Statistical, and Wave and Optics.

  17. Mid Holocene lake level and shoreline behavior during the Nipissing phase of the upper Great Lakes at Alpena, Michigan, USA

    Science.gov (United States)

    Thompson, T.A.; Lepper, K.; Endres, A.L.; Johnston, J.W.; Baedke, S.J.; Argyilan, E.P.; Booth, R.K.; Wilcox, D.A.

    2011-01-01

    The Nipissing phase was the last pre-modern high-water stage of the upper Great Lakes. Represented as either a one- or two-peak highstand, the Nipissing occurred following a long-term lake-level rise. This transgression was primarily an erosional event with only the final stage of the transgression preserved as barriers, spits, and strandplains of beach ridges. South of Alpena, Michigan, mid to late Holocene coastal deposits occur as a strandplain between Devils Lake and Lake Huron. The landward part of this strandplain is a higher elevation platform that formed during the final stage of lake-level rise to the Nipissing peak. The pre-Nipissing shoreline transgressed over Devils Lake lagoonal deposits from 6.4 to 6.1. ka. The first beach ridge formed ~ 6. ka, and then the shoreline advanced toward Lake Huron, producing beach ridges about every 70. years. This depositional regression produced a slightly thickening wedge of sediment during a lake-level rise that formed 20 beach ridges. The rise ended at 4.5. ka at the Nipissing peak. This peak was short-lived, as lake level fell > 4. m during the following 500. years. During this lake-level rise and subsequent fall, the shoreline underwent several forms of shoreline behavior, including erosional transgression, aggradation, depositional transgression, depositional regression, and forced regression. Other upper Great Lakes Nipissing platforms indicate that the lake-level change observed at Alpena of a rapid pre-Nipissing lake-level rise followed by a slower rise to the Nipissing peak, and a post-Nipissing rapid lake-level fall is representative of mid Holocene lake level in the upper Great Lakes. ?? 2011 Elsevier B.V.

  18. Laser-excited photoluminescence of three-layer GaAs double-heterostructure laser material

    International Nuclear Information System (INIS)

    Nash, F.R.; Dixon, R.W.; Barnes, P.A.; Schumaker, N.E.

    1975-01-01

    The successful fabrication of high-quality DH GaAs lasers from a simplified three-layer structure is reported. A major asset of this structure is the transparency of its final layer to recombination radiation occurring in the active layer, thus permitting the use of nondestructive photoluminescent techniques for material evaluation prior to device fabrication. In the course of photoluminescence investigations on this material the additional important observation has been made that indirect excitation (in which photocarriers are generated in the top ternary layer) has significant advantages over direct excitation (in which photocarriers are generated directly in the active layer). These include (i) the direct measurement of Al concentrations in both upper layers, (ii) the measurements of the minority-carrier diffusion length in the upper layer, (iii) an easily obtained indication of taper in the thickness of the upper layer, and (iv) surprisingly effective excitation of the active layer. By combining direct and indirect excitation it is shown that a clearer understanding of the location and detrimental influences of defects in the GaAs laser structure may be obtained. For example, the width of the region of reduced luminescence associated with many defects is found to be very excitation dependent and is confirmed to arise fr []m reduced active region luminescence. The photoluminescent excitation techniques described should be useful in the study of other heterostructure devices and material systems

  19. Research and development cooperation project on environmental measurement using laser radar in fiscal 1994; Kankyo keisokuyo laser radar no kaihatsu ni kansuru kenkyu kyoryoku

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-03-01

    The paper outlined activities in fiscal 1994 in the R and D cooperation project on a laser radar for environmental measurement. In the activities in fiscal 1994 of `the ODA laser radar development committee,` the committee held four meetings, two field surveys were carried out, and two researchers were invited from Indonesia. In the field survey, the environment in Jakarta city was investigated in terms of changes in population and number of the cars registered. Further, from data collected during 1994-1998 in the central Jakarta city, the following were made clear: the trend of a decrease in SO2, the trend of a rapid increase and an excess of NO2 content over the environmental standard, the status of pollution of which the level is close to the upper limit of the environmental standard of dust, etc. In the meeting of the policy study for the field survey at LIPI headquarters, Japan proposed a system which is constituted of a difference absorption laser radar, two Mie scattering laser radars, and a central processing unit. The sites proposed were studied in cooperation with Indonesia. 40 refs., 65 figs., 9 tabs.

  20. Low-level laser therapy equipment needs calibration before clinical use

    Science.gov (United States)

    Machado de Senna, André; Machado-de-sena, Rosa Maria; Facundes, Arseni Lázaro; Barros Nepomuceno, Patrícia; Sávya Florentino, Wanilza; Olegário de Araújo, Ronyere

    2018-04-01

    Many factors can influence the radiant power delivered by the low-level laser therapy (LLLT) equipment, such as its cleaning and condition, as well as the use of plastic films for protecting the laser or even its time of use. Radiant power is an important factor to consider because it affects the amount of energy delivered to the target tissue. The difference between real radiant power (RRP) and nominal radiant power (NRP) may interfere in the expected results, because the delivered energy is different from the desired energy. Purpose: The objective of this study was to compare the NRP with the RRP offered by LLLT devices under clinical conditions of use. Material and Methods: For data collection to this study, 61 LLLT devices used in private and public dental practices in the state of Tocantins, Brazil, were evaluated. Three consecutive power measurements were performed at one-minute intervals and then the average of the measured power was calculated. The RRP was compared to the NRP. Results: The equipment presented NRP from 30 to 500mW while RRP ranged from 17.3 to 107.0mW. Discussion and Conclusion: The mean power measured in clinical conditions of use of the laser equipment was different from the nominal power reported by the manufacturers of the devices (p<0,01). The RRP ranged between 12.92% and 107% of NRP. This fact is worrisome, since one of the most important parameters for the success of the treatment of an injury using LLLT is the energy (power x time) delivered. These findings reinforce the need of calibrating the equipment before each laser application in order to avoid failures in the therapeutic conduct.

  1. Laser Calorimetry Spectroscopy for ppm-level Dissolved Gas Detection and Analysis.

    Science.gov (United States)

    K S, Nagapriya; Sinha, Shashank; R, Prashanth; Poonacha, Samhitha; Chaudhry, Gunaranjan; Bhattacharya, Anandaroop; Choudhury, Niloy; Mahalik, Saroj; Maity, Sandip

    2017-02-20

    In this paper we report a newly developed technique - laser calorimetry spectroscopy (LCS), which is a combination of laser absorption spectroscopy and calorimetry - for the detection of gases dissolved in liquids. The technique involves determination of concentration of a dissolved gas by irradiating the liquid with light of a wavelength where the gas absorbs, and measuring the temperature change caused by the absorbance. Conventionally, detection of dissolved gases with sufficient sensitivity and specificity was done by first extracting the gases from the liquid and then analyzing the gases using techniques such as gas chromatography. Using LCS, we have been able to detect ppm levels of dissolved gases without extracting them from the liquid. In this paper, we show the detection of dissolved acetylene in transformer oil in the mid infrared (MIR) wavelength (3021 nm) region.

  2. Laboratory methods for evaluating the effect of low level laser ...

    African Journals Online (AJOL)

    The basic tenet of laser therapy is that laser radiation has a wavelength dependent capability to alter cellular behaviour in the absence of significant heating. Low intensity radiation can inhibit as well as stimulate cellular activity. Laser therapy typically involves the delivery of 1-4J/cm 2 to treatments sites with lasers having ...

  3. Low level laser therapy and hair regrowth: an evidence-based review.

    Science.gov (United States)

    Zarei, Mina; Wikramanayake, Tongyu C; Falto-Aizpurua, Leyre; Schachner, Lawrence A; Jimenez, Joaquin J

    2016-02-01

    Despite the current treatment options for different types of alopecia, there is a need for more effective management options. Recently, low-level laser therapy (LLLT) was evaluated for stimulating hair growth. Here, we reviewed the current evidence on the LLLT effects with an evidence-based approach, focusing more on randomized controlled studies by critically evaluating them. In order to investigate whether in individuals presenting with hair loss (male pattern hair loss (MPHL), female pattern hair loss (FPHL), alopecia areata (AA), and chemotherapy-induced alopecia (CIA)) LLLT is effective for hair regrowth, several databases including PubMed, Google Scholar, Medline, Embase, and Cochrane Database were searched using the following keywords: Alopecia, Hair loss, Hair growth, Low level laser therapy, Low level light therapy, Low energy laser irradiation, and Photobiomodulation. From the searches, 21 relevant studies were summarized in this review including 2 in vitro, 7 animal, and 12 clinical studies. Among clinical studies, only five were randomized controlled trials (RCTs), which evaluated LLLT effect on male and female pattern hair loss. The RCTs were critically appraised using the created checklist according to the Critical Appraisal for Therapy Articles Worksheet created by the Center of Evidence-Based Medicine, Oxford. The results demonstrated that all the performed RCTs have moderate to high quality of evidence. However, only one out of five studies performed intention-to-treat analysis, and only another study reported the method of randomization and subsequent concealment of allocation clearly; all other studies did not include this very important information in their reports. None of these studies reported the treatment effect of factors such as number needed to treat. Based on this review on all the available evidence about effect of LLLT in alopecia, we found that the FDA-cleared LLLT devices are both safe and effective in patients with MPHL and FPHL

  4. New even parity energy levels of Pr I found by excitation of transitions in the region 560 - 695 nm

    Energy Technology Data Exchange (ETDEWEB)

    Syed, Tanweer Iqbal; Khan, Shamim; Imran, Siddiqui; Zaheer, Uddin; Windholz, Laurentius [Inst. f. Experimentalphysik, Techn. Univ. Graz, Petersgasse 16, A-8010 Graz (Austria)

    2011-07-01

    The knowledge of electronic levels is essentially needed for a description of the interactions between the electrons of an atom and for the classification of an atomic spectrum. We have studied the hyperfine structure of Praseodymium spectral lines in the region from 560 to 695 nm. The hyperfine structure of a large number of unclassified Pr I-lines have been investigated by using the method of laser induced fluorescence in a hollow cathode discharge. During this investigation, we have discovered twelve energy levels with even parity, which were previously unknown. The excitation source was a ring dye laser operated with R6G, Kiton red, or DCM. J-quantum numbers and magnetic dipole interaction constants A for upper and lower levels have been determined from the recorded hyperfine structures. The energies of new levels have been determined by using these constants, excitation and fluorescence wavelengths. Promising excitation wavelengths have been taken from Fourier transform spectra. The new levels were confirmed by at least one second laser excitation.

  5. Metacognitive gimmicks and their use by upper level physics students

    Science.gov (United States)

    White, Gary; Sikorski, Tiffany-Rose; Landay, Justin

    2017-01-01

    We report on the initial phases of a study of three particular metacognitive gimmicks that upper-level physics students can use as a tool in their problem-solving kit, namely: checking units for consistency, discerning whether limiting cases match physical intuition, and computing numerical values for reasonable-ness. Students in a one semester Griffiths electromagnetism course at a small private urban university campus are asked to respond to explicit prompts that encourage adopting these three methods for checking answers to physics problems, especially those problems for which an algebraic expression is part of the final answer. We explore how, and to what extent, these students adopt these gimmicks, as well as the time development of their use. While the term ``gimmick'' carries with it some pejorative baggage, we feel it describes the essential nature of the pedagogical idea adequately in that it gets attention, is easy for the students to remember, and represents, albeit perhaps in a surface way, some key ideas about which professional physicists care.

  6. Fractional laser skin resurfacing.

    Science.gov (United States)

    Alexiades-Armenakas, Macrene R; Dover, Jeffrey S; Arndt, Kenneth A

    2012-11-01

    Laser skin resurfacing (LSR) has evolved over the past 2 decades from traditional ablative to fractional nonablative and fractional ablative resurfacing. Traditional ablative LSR was highly effective in reducing rhytides, photoaging, and acne scarring but was associated with significant side effects and complications. In contrast, nonablative LSR was very safe but failed to deliver consistent clinical improvement. Fractional LSR has achieved the middle ground; it combined the efficacy of traditional LSR with the safety of nonablative modalities. The first fractional laser was a nonablative erbium-doped yttrium aluminum garnet (Er:YAG) laser that produced microscopic columns of thermal injury in the epidermis and upper dermis. Heralding an entirely new concept of laser energy delivery, it delivered the laser beam in microarrays. It resulted in microscopic columns of treated tissue and intervening areas of untreated skin, which yielded rapid reepithelialization. Fractional delivery was quickly applied to ablative wavelengths such as carbon dioxide, Er:YAG, and yttrium scandium gallium garnet (2,790 nm), providing more significant clinical outcomes. Adjustable laser parameters, including power, pitch, dwell time, and spot density, allowed for precise determination of percent surface area, affected penetration depth, and clinical recovery time and efficacy. Fractional LSR has been a significant advance to the laser field, striking the balance between safety and efficacy.

  7. Do Activity Level Outcome Measures Commonly Used in Neurological Practice Assess Upper-Limb Movement Quality?

    Science.gov (United States)

    Demers, Marika; Levin, Mindy F

    2017-07-01

    Movement is described in terms of task-related end point characteristics in external space and movement quality (joint rotations in body space). Assessment of upper-limb (UL) movement quality can assist therapists in designing effective treatment approaches for retraining lost motor elements and provide more detailed measurements of UL motor improvements over time. To determine the extent to which current activity level outcome measures used in neurological practice assess UL movement quality. Outcome measures assessing arm/hand function at the International Classification of Function activity level recommended by neurological clinical practice guidelines were reviewed. Measures assessing the UL as part of a general mobility assessment, those strictly evaluating body function/structure or participation, and paediatric measures were excluded. In all, 15 activity level outcome measures were identified; 9 measures assess how movement is performed by measuring either end point characteristics or movement quality. However, except for the Reaching Performance Scale for Stroke and the Motor Evaluation Scale for Upper Extremity in Stroke Patients, these measures only account for deficits indirectly by giving a partial score if movements are slower or if the person experiences difficulties. Six outcome measures neither assess any parameters related to movement quality, nor distinguish between improvements resulting from motor compensation or recovery of desired movement strategies. Current activity measures may not distinguish recovery from compensation and adequately track changes in movement quality over time. Movement quality may be incorporated into clinical assessment using observational kinematics with or without low-cost motion tracking technology.

  8. Comparing the efficiency of Er,Cr:YSGG laser and diode laser on human β-defensin-1 and IL-1β levels during the treatment of generalized aggressive periodontitis and chronic periodontitis.

    Science.gov (United States)

    Ertugrul, Abdullah Seckin; Tekin, Yasin; Talmac, Ahmet Cemil

    2017-11-01

    The aim of this study is to determine the suitability of the Er,Cr:YSGG and 940 ± 15-nm diode laser for the treatment of generalized aggressive periodontitis and chronic periodontitis by measuring the levels of human β-defensin-1 and IL-1β. A total of 26 patients were included in this study. The study was designed as a "split-mouth" experiment. We performed scaling and root planing in the right maxillary quadrant, scaling and root planning + Er,Cr:YSGG laser in the left maxillary quadrant, scaling and root planning + 940 ± 15-nm diode laser in the left mandibular quadrant, and only scaling and root planing in the right mandibular quadrant. The presence of human β-defensin-1 and IL-1β was analyzed with an ELISA. When the baseline and post-treatment human β-defensin-1 levels and IL-1β levels of the study groups were evaluated, a decrease in human β-defensin-1 and IL-1β were observed in the quadrant where the Er,Cr:YSGG laser was applied in both the generalized aggressive periodontitis group and the chronic periodontitis group. The use of the Er,Cr:YSGG laser at non-surgical periodontal treatment decreased both IL-1β and human β-defensin-1 levels. It is likely that Er,Cr:YSGG laser is more suitable for the treatment of generalized aggressive periodontitis and chronic periodontitis.

  9. Is it possible to prevent morbidity on post cardiovascular surgery applying low level laser therapy?

    Science.gov (United States)

    Pinto, Nathali C.; Baptista, Ivany Machado d. C.; Pereira, Mara Helena C.; Serrão, Nelson F.; Pomerantzeff, Pablo M. A.; Chavantes, Maria Cristina

    2014-03-01

    Background and Objective: Complications following cardiovascular surgery incision are common in mediastinitis and wound dehiscence form, a 47% mortality rate remaining. Low Level Laser Therapy (LLLT) has been employed mainly to its effectiveness analgesic and anti-inflammatory actions, aiding the tissue repair process. The aim of this study was to evaluate infrared LLLT onto surgical incision in patients submitted to cardiovascular surgery. Materials and Methods: 40 patients were divided in two groups: Placebo Group (G1) - conventional therapy + "Laser pointer" and Laser Group (G2) - conventional therapy + Infrared Laser irradiation on surgical incision. Diode Laser was employed, C.W. mode, around the surgical wound bed, on immediate Post Operative (PO), 1st PO and 3rd PO with the following parameters: wavelength (λ): 830nm, P=35mW, E=0,75J. Results: G2 didn't present any complication and 5% of patients in G1 developed incision dehiscence and infection. On 7thPO, still a large amount of G1 patients showed pain and unquestionable inflammatory signs surrounding the surgical wound, when compared to G2. Besides, hospital stay in Laser Group was 2 times shorter than in Placebo Group (p-value=0.001). Conclusion: Infrared Laser denoted to be safe and exceptionally valuable tools in preventing morbidities on post cardiovascular surgeries.

  10. Retrospective Review of Air Transportation Use for Upper Extremity Amputations at a Level-1 Trauma Center.

    Science.gov (United States)

    Grantham, W Jeffrey; To, Philip; Watson, Jeffry T; Brywczynski, Jeremy; Lee, Donald H

    2016-08-01

    Air transportation to tertiary care centers of patients with upper extremity amputations has been utilized in hopes of reducing the time to potential replantation; however, this mode of transportation is expensive and not all patients will undergo replantation. The purpose of this study is to review the appropriateness and cost of air transportation in upper extremity amputations. Consecutive patients transported by aircraft with upper extremity amputations in a 7-year period at a level-1 trauma center were retrospectively reviewed. The distance traveled was recorded, along with the times of the injury, referral, transportation duration, arrival, and start of the operation. The results of the transfer were defined as replantation or revision amputation. Overall, 47 patients were identified with 43 patients going to the operating room, but only 14 patients (30%) undergoing replantation. Patients arrived at the tertiary hand surgery center with a mean time of 182.3 minutes following the injury, which includes 105.2 minutes of transportation time. The average distance traveled was 105.4 miles (range, 22-353 miles). The time before surgery of those who underwent replantation was 154.6 minutes. The average cost of transportation was $20,482. Air transportation for isolated upper extremity amputations is costly and is not usually the determining factor for replantation. The type of injury and patients' expectations often dictate the outcome, and these may be better determined at the time of referral with use of telecommunication photos, discussion with a hand surgeon, and patient counseling. III.

  11. Integrating Wind Profiling Radars and Radiosonde Observations with Model Point Data to Develop a Decision Support Tool to Assess Upper-Level Winds for Space Launch

    Science.gov (United States)

    Bauman, William H., III; Flinn, Clay

    2013-01-01

    On the day of launch, the 45th Weather Squadron (45 WS) Launch Weather Officers (LWOs) monitor the upper-level winds for their launch customers. During launch operations, the payload/launch team sometimes asks the LWOs if they expect the upper-level winds to change during the countdown. The LWOs used numerical weather prediction model point forecasts to provide the information, but did not have the capability to quickly retrieve or adequately display the upper-level observations and compare them directly in the same display to the model point forecasts to help them determine which model performed the best. The LWOs requested the Applied Meteorology Unit (AMU) develop a graphical user interface (GUI) that will plot upper-level wind speed and direction observations from the Cape Canaveral Air Force Station (CCAFS) Automated Meteorological Profiling System (AMPS) rawinsondes with point forecast wind profiles from the National Centers for Environmental Prediction (NCEP) North American Mesoscale (NAM), Rapid Refresh (RAP) and Global Forecast System (GFS) models to assess the performance of these models. The AMU suggested adding observations from the NASA 50 MHz wind profiler and one of the US Air Force 915 MHz wind profilers, both located near the Kennedy Space Center (KSC) Shuttle Landing Facility, to supplement the AMPS observations with more frequent upper-level profiles. Figure 1 shows a map of KSC/CCAFS with the locations of the observation sites and the model point forecasts.

  12. Anterior and posterior capsule densitometry levels after femtosecond laser-assisted cataract surgery

    Directory of Open Access Journals (Sweden)

    Txomin Alberdi

    2018-04-01

    Full Text Available AIM: To analyze and compare five different variables over one year follow-up (1wk, 1, 3, 6 and 12mo: anterior capsule (AC, and posterior capsule (PC area densitometry values, AC and PC linear densitometry values, and AC opening area reduction ratio after femtosecond laser-assisted cataract surgery. METHODS: This was a prospective comparative study. Seventy-one patients underwent femtosecond laser-assisted cataract surgery on single eye between June 2014 and December 2015. A 5.0 mm diameter laser assisted anterior capsulotomy was performed on all eyes. In every post-surgery evaluation, AC opacificaction (ACO and PC opacification (PCO density levels were provided by Oculus Pentacam®HR using area and linear densitometry methods. Digital images were captured with a slit-lamp Topcon photographic camera and IMAGEnet® 5 software. The AC opening area on the digital images was measured using the Sketchandcalc area calculator and converted to reduction ratio levels. RESULTS: Using Pearson correlation coefficient (PCC, we found no correlation (r=-0.091, P=0.46 in the twelfth month assessment between the evolution of ACO area densitometry values and PCO area densitometry values considered as independent variables. We found no correlation, using PCC (r=-0.096, P=0.43 between the evolution of ACO linear densitometry values and PCO linear densitometry values, in the twelfth month visit, working both as independent variables. AC linear densitometry levels and AC area densitometry levels continued to grow strongly from sixth to twelfth months. Analysis of the values of AC opening area reduction ratio (1wk, 1, 3, 6, 12mo revealed statistically significant differences between the values of successive examinations but the magnitude of the change decreased. In the final period of monitoring between six and twelve months the magnitude of change was low. CONCLUSION: Our results show strong increases of Scheimpflug ACO densitometry values from the sixth to the

  13. Secretory IgA, albumin level, and bone density as markers of biostimulatory effects of laser radiation

    Science.gov (United States)

    Kucerova, Hana; Dostalova, Tatjana; Himmlova, Lucia; Bartova, Jirina; Mazanek, Jiri

    1998-12-01

    The aim of contribution is to evaluate the effects of low- level laser radiation on healing process after human molars extraction in lower jaw using frequency 5 Hz, 292 Hz and 9000 Hz. Changes in bone density and monitoring of secretory IgA and albumin levels in saliva were used as a marker of biostimulatory effect. Bone density after extraction and 6 month after surgical treatment was examined using the dental digital radiography. Bone healing was followed by osseointegration of bone structure in extraction wound. Changes of bone density, secretory IgA and albumin levels were compared in groups of patients with laser therapy and control group without laser therapy. Differences in levels of the saliva markers (sIgA and albumin) were found to be significant comparing irradiated and non-irradiated groups, as well as comparing groups irradiated by various modulatory frequencies. Density of alveolar bone (histogram) was examined on five slices acquired from every RVG image. Histograms were evaluated with computer program for microscopic image analysis. Differences of density were verified in area of the whole slice. There were no significant differences found between the bone density in irradiated and non irradiated groups perhaps due to our used therapeutical diagram.

  14. Baseline blood Pb levels of black-necked stilts on the upper Texas coast

    Science.gov (United States)

    Riecke, Thomas V.; Conway, Warren C.; Haukos, David A.; Moon, Jena A.; Comer, Christopher E.

    2015-01-01

    There are no known biological requirements for lead (Pb), and elevated Pb levels in birds can cause a variety of sub-lethal effects and mortality. Historic and current levels of Pb in mottled ducks (Anas fulvigula) suggest that environmental sources of Pb remain available on the upper Texas coast. Because of potential risks of Pb exposure among coexisting marsh birds, black-necked stilt (Himantopus mexicanus) blood Pb concentrations were measured during the breeding season. Almost 80 % (n = 120) of 152 sampled stilts exceeded the background threshold (>20 μg/dL) for Pb exposure. However, blood Pb concentrations did not vary by age or gender, and toxic or potentially lethal concentrations were rare (study suggest the presence of readily bioavailable sources of Pb, although potential impacts on local stilt populations remain unclear.

  15. Treatment of calculus of upper urinary tract with mini-percutaneous nephrolithotomy under ultrasound guidance

    International Nuclear Information System (INIS)

    Gao Feng; Ye Chunhua; Wang Kanger; Sun Yan

    2009-01-01

    Objective: To evaluate the feasibility and availability of minimally invasive percutaneous nephrolithotomy (MPCNL) under ultrasound guidance for treatment of calculus of upper urinary tract. Methods: The clinical data of 48 cases with calculus of upper urinary tract undergoing MPCNL were reviewed. Results: In 48 cases, cutaneous-nephric passages were successfully constructed by ultrasound guidance, stone-free rate was 90%. The average operation time was 90 minutes, the average hospitalization was 8 days. No major complications were noted. Conclusion: Under ultrasound guidance, MPCNL with holmium laser is a simply, safe and effective method for treating calculus of upper urinary tract. (authors)

  16. Photobiostimulation on chondrocytes proliferation in different concentration of fetal bovine serum under low-level laser irradiation

    Science.gov (United States)

    Zheng, Liqin; Wang, Yuhua; Qiu, Caimin; Chen, Jianlin; Yang, Hongqin; Zhang, Yanding; Xie, Shusen

    2015-03-01

    The aim of this in vitro study was to evaluate the influence of low-level laser irradiation (LLLI) on the chondrocytes proliferation cultured in different concentration of fetal bovine serum (FBS) using 658 nm, 785 nm and 830 nm diode lasers. The role of energy density (10-70 mJ·cm-2) on chondrocytes proliferation following irradiation with 658 nm laser for 2 days was firstly investigated to find out the best laser energy density. Then the effect of LLLI on the proliferation of chondrocytes cultured with fetal bovine serum at 0%, 2%, 5% and 10% was also evaluated. The results showed that there was no or little photobiostimulation on the proliferation of chondrocytes cultured with 0% FBS and 10% FBS; the cell proliferation at 2% and 5% FBS was significantly modulated by LLLI.

  17. Mixed garnet laser crystals for water vapour DIAL transmitter

    Science.gov (United States)

    Treichel, Rainer; Czeranowsky, Christoph; Ileri, Bilge; Petermann, Klaus; Huber, Günter

    2017-11-01

    There are more or less well established technologies such as the optical-parametric-oscillator (OPO), the Raman-laser, and the Ti-Sapphire laser, which are able to emit laser light in the region of the water vapour absorption lines. For WALES the regions of about 935 nm, 942 nm, and 944 nm have been identified as the most suitable wavelength ranges. However, each of these laser designs is highly sophisticated. Current baseline for WALES is the Ti-Sapphire laser. A fourth possibility to achieve these wavelength ranges is to shift the groundstate laser lines (938 nm and 946 nm) of the Nd:YAG laser by replacing Aluminium and Yttrium by other rare earth elements. Changes of the host lattice characteristics lead to a shift of the upper and lower laser levels. These modified crystals are summarized under the name of "Mixed Garnet" crystals. Only the Mixed Garnet lasers can be pumped directly with diode laser and use a direct approach to generate the required laser pulses without frequency conversion. Therefore no additional non-linear crystals are needed and a higher electric to optical efficiency is expected as well as single frequency operation using spectral tuning elements like etalons. Such lasers have the great potential to fulfil the requirements and to become the preferred transmitter concept for WALES as well as for follow up missions. Within a ESA study several crystal compositions have been grown, spectrally characterised and analysed. Absorbed space radiation energy in the crystal lattice causes colour centres, which can reabsorb the pump and laser wavelength and consequently reduce the laser gain considerably. Co-dopants such as Chromium and Cerium are able to suppress the colour centres and are candidates for effective radiation hardening. The results of the crystal tuning, the co-doping with different radiation hardeners and the radiation tests will be presented. There applicability for a space based water vapour DIAL transmitter will be discussed.

  18. Radiological protection against lasers

    Energy Technology Data Exchange (ETDEWEB)

    Ballereau, P

    1974-04-01

    A brief description of the biological effects of laser beams is followed by a review of the factors involved in eye and skin damage (factors linked with the nature of lasers and those linked with the organ affected) and a discussion of the problems involved in the determination of threshold exposure levels. Preventive measures are recommended, according to the type of laser (high-energy pulse laser, continuous laser, gas laser). No legislation on the subject exists in France or in Europe. Types of lasers marketed, threshold exposure levels for eye and skin, variations of admissible exposure levels according to wavelength, etc. are presented in tabular form. Nomogram for determination of safe distance for direct vision of a laser is included.

  19. Efficacy of low level laser therapy in the treatment of burning mouth syndrome: A systematic review.

    Science.gov (United States)

    Al-Maweri, Sadeq Ali; Javed, Fawad; Kalakonda, Butchibabu; AlAizari, Nader A; Al-Soneidar, Walid; Al-Akwa, Ameen

    2017-03-01

    Burning mouth syndrome (BMS) is a chronic pain condition with indefinite cure, predominantly affecting post-menopausal women. The aim of this study was to systematically review the efficacy of low level laser therapy in the treatment of burning mouth syndrome (BMS). PubMed, Embase and Scopus were searched from date of inception till and including October 2016 using various combinations of the following keywords: burning mouth syndrome, BMS, stomatodynia, laser therapy, laser treatment and phototherapy. The inclusion criteria were: Prospective, retrospective and case series studies. Letter to editors, reviews, experimental studies, studies that were not published in English, theses, monographs, and abstracts presented in scientific events were excluded. Due to heterogeneity of data no statistical analyses were performed. Ten clinical studies fulfilled the eligibility criteria, five of which were randomized clinical trials. In these studies, the laser wavelengths, power output and duration of irradiation ranged between 630-980nm, 20-300mW, 10s-15min, respectively. Most of studies reported laser to be an effective therapy strategy for management of BMS. Majority of the studies showed that laser therapy seemed to be effective in reducing pain in BMS patients. However, due to the varied methodologies and substantial variations in laser parameters among these studies, more clinical trials are required to ascertain the efficacy of laser for treating BMS. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Comparison of Different Energy Levels of Er:YAG Laser Regarding Intrapulpal Temperature Change During Safe Ceramic Bracket Removal.

    Science.gov (United States)

    Nalbantgil, Didem; Tozlu, Murat; Oztoprak, Mehmet Oguz

    2018-04-01

    This study was done to compare the intrapulpal temperature change generated by different energy levels of Er:YAG laser used during debonding of ceramic brackets and find the most suitable level for clinical use. Eighty polycrystalline alumina brackets were bonded on bovine incisor teeth, which were randomly divided into 4 groups of 20. One group was assigned as control. In the study groups, after laser exposure with 2, 4, or 6 Watt energy levels, brackets were debonded using an Instron Universal Testing machine. Adhesive remnant index (ARI) scores were recorded to evaluate the site of debonding. To assess intrapulpal thermal increase, 60 human premolar teeth that were prepared in the same way, at the same energy levels, by a thermocouple were used. When the debonding forces, intrapulpal temperature increases, and ARI of the groups were examined, statistically significant difference was observed between the groups. Mean temperature increases of 0.67°C ± 0.12°C, 1.25°C ± 0.16°C, and 2.36°C ± 0.23°C were recorded for the 2, 4, and 6 Watt laser groups. The mean shear bond strength was 21.35 ± 3.43 megapascals (MPa) for the control group, whereas they were 8.79 ± 2.47, 3.28 ± 0.73, and 2.46 ± 0.54 MPa for the 2, 4, and 6 Watt laser groups, respectively. Four watts is the most efficient and safe energy level to be used, utilizing Er:YAG laser with water cooling spray for 6 sec by scanning method during debonding of polycrystalline alumina brackets without any carbonization effects and detrimental temperature changes at debond sites.

  1. Quantitative description of the saturated absorption signal in iodine stabilized He-Ne lasers

    International Nuclear Information System (INIS)

    Brillet, A.; Cerez, P.

    1977-01-01

    He-Ne lasers stabilized by saturated absorption 127 I 2 have been studied in many laboratories and are now widely used as optical frequency standards. But, although their frequency stability and reproducibility have been extensively measured and reported, the size and the width of the saturated absorption signals used for the stabilization are not yet well understood. Particularly, the extrapolation of the linewidth to zero pressure results in an apparent discrepancy with the lifetime of the upper level of the transition. By measuring or evaluating all the important parameters which affect the operation of these lasers we are now able to describe with a good accuracy the properties of the saturated absorption signal and their variations with the iodine pressure, using Greenstein's theory of a laser with an internal absorption cell. At low iodine pressures (typically below 100 m Torr), we observe a divergence between experimental and theoretical results, which is interpreted as an effect of the laser beam geometry, when the saturation parameter becomes much larger than 1. (orig.) [de

  2. Laser surface treatment on a nickel based alloy in order to form chromium oxide to reduce cations release in primary circuit. Experimental and numerical study of laser mater interaction

    International Nuclear Information System (INIS)

    Gouton, Lucille

    2015-01-01

    Alloy 690 (60%Ni, 30%Cr, 10%Fe) is mainly used in primary circuit pipes for nuclear power plants.The aim of this thesis is to form a Cr 2 O 3 layer, using laser surface melting, with the objective of creating a chromium-rich oxide layer. In order to optimize the treatment, it was first important to determine parameters influence on the layer oxide properties then, with the objective of a deeper understanding of mechanisms involved, to address thermo-physical phenomena occurring during and after the laser pulse striking the upper surface. A deep parametric study first enabled to find an optimized laser surface treatment which produces chromium enrichment of the upper surface and a dense and continuous oxide layer. This treatment has been applied on samples, set in a primary medium simulation loop. Experiments and calculations were carried out to provide understanding of surface chromium enrichment by laser process. The results were shown to explain chromium enrichment until melt pool solidification occurred on the upper surface, assumingly just before chromium oxide formation. This was also promoted by a high affinity with oxygen and a higher stability of Cr 2 O 3 oxide compared with other potential oxide formation. (author) [fr

  3. Resonance fluorescence spectra of a three-level atom driven by two strong laser fields

    International Nuclear Information System (INIS)

    Peng Jinsheng.

    1986-12-01

    The resonance fluorescence of a three-level atom interacted with two high-power laser fields is investigated in strong field approximation. The fluorescence distribution is obtained by means of the theory of dressing transformation. (author). 15 refs, 2 figs

  4. Coherent population transfer and superposition of atomic states via stimulated Raman adiabatic passage using an excited-doublet four-level atom

    International Nuclear Information System (INIS)

    Jin Shiqi; Gong Shangqing; Li Ruxin; Xu Zhizhan

    2004-01-01

    Coherent population transfer and superposition of atomic states via a technique of stimulated Raman adiabatic passage in an excited-doublet four-level atomic system have been analyzed. It is shown that the behavior of adiabatic passage in this system depends crucially on the detunings between the laser frequencies and the corresponding atomic transition frequencies. Particularly, if both the fields are tuned to the center of the two upper levels, the four-level system has two degenerate dark states, although one of them contains the contribution from the excited atomic states. The nonadiabatic coupling of the two degenerate dark states is intrinsic, it originates from the energy difference of the two upper levels. An arbitrary superposition of atomic states can be prepared due to such nonadiabatic coupling effect

  5. Levels of interleukin-6 in tears before and after excimer laser treatment

    Directory of Open Access Journals (Sweden)

    Resan Mirko

    2015-01-01

    Full Text Available Background/Aim. Immune response and consequent inflammatory process which originate on ocular surface after a trauma are mediated by cytokines. Photoablation of corneal stroma performed by excimer laser causes surgically induced trauma. Interleukin-6 (IL-6 is mostly known as a proinflammatory cytokine. However, it also has regenerative and anti-inflammatory effects. It is supposed that this cytokine is likely to play a significant role in the process of corneal wound healing response after photoablation of stroma carried out by laser in situ keratomileusis (LASIK or photorefractive keratectomy (PRK methods. The aim of this study was to determine and compare the levels of IL-6 in tears before and after treatment with LASIK and PRK methods. Methods. The study included 68 shortsighted eyes up to -3.0 diopter sphere, i.e. 198 samples of tears (per three samples taken from each of the eyes, divided into two groups according to the kind of excimer laser intervention performed: the group 1 - eyes treated by LASIK method (n = 31, and the group 2 - eyes treated by the PRK method (n = 37. The samples of tears were taken from each eye at the following time points: before excimer laser treatment (0 h, the control group, 1 h after the treatment (1 h and 24 h after the treatment (24 h. The patients did not use anti-inflammatory therapy 24 h after the intervention. Tear samples were collected using microsurgical sponge. Level of IL-6 in tear fluid was determined by the flow cytometry method, applying a commercial test kit which allowed cytokine detection from a small sample volume. Results. The values of IL-6 were detectable in 16% of samples before LASIK treatment and in 30% of samples before PRK treatment. One h after the treatment IL-6 was detectable in 29% of samples for the LASIK group and 43% of samples for the PRK group, and 24 h after the treatment it was detectable in 19% of samples for the LASIK group and in 57% of samples for the PRK group. When we

  6. Levels of interleukin-6 in tears before and after excimer laser treatment.

    Science.gov (United States)

    Resan, Mirko; Stanojević, Ivan; Petković, Aleksandra; Pajić, Bojan; Vojvodić, Danilo

    2015-04-01

    Immune response and consequent inflammatory process which originate on ocular surface after a trauma are mediated by cytokines. Photoablation of corneal stroma performed by excimer laser causes surgically induced trauma. Interleukin-6 (IL-6) is mostly known as a proinflammatory cytokine. However, it also has regenerative and anti-inflammatory effects. It is supposed that this cytokine is likely to play a significant role in the process of corneal wound healing response after photoablation of stroma carried out by laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) methods. The aim of this study was to determine and compare the levels of IL-6 in tears before and after treatment with LASIK and PRK methods. The study included 68 shortsighted eyes up to -3.0 diopter sphere, i.e. 198 samples of tears (per three samples taken from each of the eyes), divided into two groups according to the kind of excimer laser intervention performed: the group 1--eyes treated by LASIK method (n=31), and the group 2--eyes treated by the PRK method (n=37). The samples of tears were taken from each eye at the following time points: before excimer laser treatment (0 h, the control group), 1 h after the treatment (1 h) and 24 h after the treatment (24 h). The patients did not use anti-inflammatory therapy 24 h after the intervention. Tear samples were collected using microsurgical sponge. Level of IL-6 in tear fluid was determined by the flow cytometry method, applying a commercial test kit which allowed cytokine detection from a small sample volume. Results. The values of IL-6 were detectable in 16% of samples before LASIK treatment and in 30% of samples before PRK treatment. One h after the treatment IL-6 was detectable in 29% of samples for the LASIK group and 43% of samples for the PRK group, and 24 h after the treatment it was detectable in 19% of samples for the LASIK group and in 57% of samples for the PRK group. When we analyzed the dynamics of IL76 production

  7. Oncoplastic Surgery for Upper/Upper Inner Quadrant Breast Cancer.

    Science.gov (United States)

    Lin, Joseph; Chen, Dar-Ren; Wang, Yu-Fen; Lai, Hung-Wen

    2016-01-01

    Tumors located in the upper/upper inner quadrant of the breast warrant more attention. A small lesion relative to the size of breast in this location may be resolved by performing a level I oncoplastic technique. However, a wide excision may significantly reduce the overall quality of the breast shape by distorting the visible breast line. From June 2012 to April 2015, 36 patients with breast cancer located in the upper/upper inner quadrant underwent breast-conservation surgery with matrix rotation mammoplasty. According to the size and location of the tumor relative to the nipple-areola complex, 11 patients underwent matrix rotation with periareolar de-epithelialization (donut group) and the other 25 underwent matrix rotation only (non-donut group). The cosmetic results were self-assessed by questionnaires. The average weights of the excised breast lumps in the donut and non-donut groups were 104.1 and 84.5 g, respectively. During the 3-year follow-up period, local recurrence was observed in one case and was managed with nipple-sparing mastectomy followed by breast reconstruction with prosthetic implants. In total, 31 patients (88.6%) ranked their postoperative result as either acceptable or satisfactory. The treated breasts were also self-evaluated by 27 patients (77.1%) to be nearly identical to or just slightly different from the untreated side. Matrix rotation is an easy breast-preserving technique for treating breast cancer located in the upper/upper inner quadrant of the breast that requires a relatively wide excision. With this technique, a larger breast tumor could be removed without compromising the breast appearance.

  8. Dentinal hypersensitivity following scaling and root planing: comparison of low-level laser and topical fluoride treatment.

    Science.gov (United States)

    Pesevska, Snezana; Nakova, Marija; Ivanovski, Kiro; Angelov, Nikola; Kesic, Ljiljana; Obradovic, Radmila; Mindova, Sonja; Nares, Salvador

    2010-09-01

    The aim of this study is to compare the effectiveness of low-level laser irradiation to traditional topical fluoride treatment for treatment choices of dentinal hypersensitivity following scaling and root planing. The experimental group (15 patients) was treated with low-energy-level diode laser at each site of dentinal hypersensitivity following scaling and root planning. The control group (15 patients) received topical fluoride treatment (protective varnish for desensitization). All the patients were treated at baseline visit, and then at day 2 and 4 after the initial treatment; the pain was subjectively assessed by the patients as strong, medium, medium low, low, or no pain. Total absence of the dental hypersensitivity was reported in 26.66% of the examined group even after the second visit, compared to the control group where complete resolution of the hypersensitivity was not present after the second visit in any of the treated cases. Complete absence of pain was achieved in 86.6% of patients treated with laser and only in 26.6% in the fluoride treated group, after the third visit. Based on our findings, we conclude that low-energy biostimulative laser treatment can be successfully used for treatment of dental hypersensitivity following scaling and root planing.

  9. Spectroscopic and radiation-resistant properties of Er,Pr:GYSGG laser crystal operated at 2.79 μm

    International Nuclear Information System (INIS)

    Zhao Xu-Yao; Sun Dun-Lu; Luo Jian-Qiao; Zhang Hui-Li; Fang Zhong-Qing; Quan Cong; Li Xiu-Li; Cheng Mao-Jie; Zhang Qing-Li; Yin Shao-Tang

    2017-01-01

    We demonstrate the spectroscopic and laser performance before and after 100 Mrad gamma-ray irradiation on an Er,Pr:GYSGG crystal grown by the Czochralski method. The additional absorption of Er,Pr:GYSGG crystal is close to zero in the 968 nm pumping and 2.7–3 μm laser wavelength regions. The lifetimes of the upper and lower levels show faint decreases after gamma-ray irradiation. The maximum output powers of 542 and 526 mW with the slope efficiencies of 17.7% and 17.0% are obtained, respectively, on the GYSGG/Er,Pr:GYSGG composite crystal before and after the gamma-ray irradiation. These results suggest that Er,Pr:GYSGG crystal as a laser gain medium possesses a distinguished anti-radiation ability for application in space and radiant environments. (paper)

  10. Investigating the CO 2 laser cutting parameters of MDF wood composite material

    Science.gov (United States)

    Eltawahni, H. A.; Olabi, A. G.; Benyounis, K. Y.

    2011-04-01

    Laser cutting of medium density fibreboard (MDF) is a complicated process and the selection of the process parameters combinations is essential to get the highest quality cut section. This paper presents a means for selecting the process parameters for laser cutting of MDF based on the design of experiments (DOE) approach. A CO 2 laser was used to cut three thicknesses, 4, 6 and 9 mm, of MDF panels. The process factors investigated are: laser power, cutting speed, air pressure and focal point position. In this work, cutting quality was evaluated by measuring the upper kerf width, the lower kerf width, the ratio between the upper kerf width to the lower kerf width, the cut section roughness and the operating cost. The effect of each factor on the quality measures was determined. The optimal cutting combinations were presented in favours of high quality process output and in favours of low cutting cost.

  11. Changes of blood levels of LPO, SOD and GSH-Px after endovenous laser treatment of varicose greater saphenous vein

    International Nuclear Information System (INIS)

    Han Li'na; Gu Ying; Liu Fanguang

    2004-01-01

    Objective: To investigate the changes of the blood levels of lipid peroxide (LPO), superoxide dismutase (SOD) and glutathione peroxidase (GSH-Px) after treatment of varicose greater saphenous vein with either endovenous laser or conventional surgery (high ligation plus stripping). Methods: Thirty-seven patients with varicose greater saphenous vein were treated with endovenous laser and another 33 patients were treated with conventional surgery. Levels of LPO (serum, with TBA fluorescein), SOD (whole blood, with RIA) and GSH-Px (whole blood, with direct DTNB) were determined in these patients both before and 1, 3, 5, 7, 10, 15 days after treatment. Levels in 30 controls were also measured. Results: The levels of LPO were higher and levels of SOD, GSH-Px lower in the patients than those in the controls. After either form of therapy, the levels LPO rose and levels of SOD, GSH-Px dropped immediately but gradually approached the control values by the 15 th day (slower with SOD and GSH-Px). However, the early increase of LPO levels were less and recovery sooner in the group of patients treated with laser. Conclusion: Changes of levels of LPO, SOD and GSH-Px were closely related to the degree of stress and recovery condition after the treatment

  12. Could low level laser therapy and highly active antiretroviral therapy lead to complete eradication of HIV-1 in vitro?

    CSIR Research Space (South Africa)

    Lugongolo, Masixole Y

    2017-01-01

    Full Text Available used to treat different medical conditions such as diabetic wounds, sports injuries and others. The technique involves exposure of cells or tissue to low levels of red and near infrared laser light. Both HIV infected and uninfected cells were laser...

  13. Information entropy of a time-dependent three-level trapped ion interacting with a laser field

    International Nuclear Information System (INIS)

    Abdel-Aty, Mahmoud

    2005-01-01

    Trapped and laser-cooled ions are increasingly used for a variety of modern high-precision experiments, frequency standard applications and quantum information processing. Therefore, in this communication we present a comprehensive analysis of the pattern of information entropy arising in the time evolution of an ion interacting with a laser field. A general analytic approach is proposed for a three-level trapped-ion system in the presence of the time-dependent couplings. By working out an exact analytic solution, we conclusively analyse the general properties of the von Neumann entropy and quantum information entropy. It is shown that the information entropy is affected strongly by the time-dependent coupling and exhibits long time periodic oscillations. This feature attributed to the fact that in the time-dependent region Rabi oscillation is time dependent. Using parameters corresponding to a specific three-level ionic system, a single beryllium ion in a RF-(Paul) trap, we obtain illustrative examples of some novel aspects of this system in the dynamical evolution. Our results establish an explicit relation between the exact information entropy and the entanglement between the multi-level ion and the laser field. We show that different nonclassical effects arise in the dynamics of the ionic population inversion, depending on the initial states of the vibrational motion/field and on the values of Lamb-Dicke parameter η

  14. Biomechanical properties: effects of low-level laser therapy and Biosilicate® on tibial bone defects in osteopenic rats.

    Science.gov (United States)

    Fangel, Renan; Bossini, Paulo S; Renno, Ana Cláudia; Granito, Renata N; Wang, Charles C; Nonaka, Keico O; Driusso, Patricia; Parizotto, Nivaldo A; Oishi, Jorge

    2014-12-30

    The aim of this study was to investigate the effects of laser therapy and Biosilicate® on the biomechanical properties of bone callus in osteopenic rats. Fifty female Wistar rats were equally divided into 5 groups (n=10/group): osteopenic rats with intact tibiae (SC); osteopenic rats with unfilled and untreated tibial bone defects (OC); osteopenic rats whose bone defects were treated with Biosilicate® (B); osteopenic rats whose bone defects were treated with 830-nm laser, at 120 J/cm2 (L120) and osteopenic rats whose bone defects were treated with Biosilicate® and 830-nm laser, at 120 J/cm2 (BL120). Ovariectomy (OVX) was used to induce osteopenia. A non-critical bone defect was created on the tibia of the osteopenic animals 8 weeks after OVX. In Biosilicate® groups, bone defects were completely filled with the biomaterial. For the laser therapy, an 830-nm laser, 120 J/cm2 was used. On day 14 postsurgery, rats were euthanized, and tibiae were removed for biomechanical analysis. Maximal load and energy absorption were higher in groups B and BL120, according to the indentation test. Animals submitted to low-level laser therapy (LLLT) did not show any significant biomechanical improvement, but the association between Biosilicate® and LLLT was shown to be efficient to enhance callus biomechanical properties. Conversely, no differences were found between study groups in the bending test. Biosilicate® alone or in association with low level laser therapy improves biomechanical properties of tibial bone callus in osteopenic rats.

  15. Current Laser Resurfacing Technologies: A Review that Delves Beneath the Surface

    Science.gov (United States)

    Preissig, Jason; Hamilton, Kristy; Markus, Ramsey

    2012-01-01

    Numerous laser platforms exist that rejuvenate the skin by resurfacing its upper layers. In varying degrees, these lasers improve the appearance of lentigines and rhytides, eliminate photoaging, soften scarring due to acne and other causes, and treat dyspigmentation. Five major classes of dermatologic lasers are currently in common use: ablative and nonablative lasers in both fractionated and unfractionated forms as well as radiofrequency technologies. The gentler nonablative lasers allow for quicker healing, whereas harsher ablative lasers tend to be more effective. Fractionating either laser distributes the effect, increasing the number of treatments but minimizing downtime and complications. In this review article, the authors seek to inform surgeons about the current laser platforms available, clarify the differences between them, and thereby facilitate the identification of the most appropriate laser for their practice. PMID:23904818

  16. Trends in Upper-Level Cloud Cover and Surface Divergence Over the Tropical Indo-Pacific Ocean Between 1952 And 1997

    Science.gov (United States)

    Norris, Joel R.

    2005-01-01

    This study investigated the spatial pattern of linear trends in surface-observed upper-level (combined mid-level and High-level) cloud cover, precipitation, and surface divergence over the tropical Indo-Pacific Ocean during 1952-1957. Cloud values were obtained from the Extended Edited Cloud Report Archive (EECRA), precipitation values were obtained from the Hulme/Climate Research Unit Data Set, and surface divergence was alternatively calculated from wind reported Comprehensive Ocean-Atmosphere Data Set and from Smith and Reynolds Extended Reconstructed sea level pressure data.

  17. Watt-level ~2 μm laser output in Tm3+-doped tungsten tellurite glass double-cladding fiber.

    Science.gov (United States)

    Li, Kefeng; Zhang, Guang; Hu, Lili

    2010-12-15

    We report, for the first time to the best of our knowledge, a watt level cw fiber laser at ~2 μm from a piece of 40-cm-long newly developed highly thulium-doped (3.76 × 10(20) ions/cm(3)) tungsten tellurite glass double cladding fiber pumped by a commercial 800 nm laser diode. The maximum output power of the fiber laser reaches 1.12 W. The slope efficiency and the optical-optical efficiency with respect to the absorbed pump are 20% and 16%, respectively. The lasing threshold is 1.46 W, and the lasing wavelength is centered at 1937 nm.

  18. Adiabatic interpretation of a two-level atom diode, a laser device for unidirectional transmission of ground-state atoms

    International Nuclear Information System (INIS)

    Ruschhaupt, A.; Muga, J. G.

    2006-01-01

    We present a generalized two-level scheme for an 'atom diode', namely, a laser device that lets a two-level ground-state atom pass in one direction, say from left to right, but not in the opposite direction. The laser field is composed of two lateral state-selective mirror regions and a central pumping region. We demonstrate the robustness of the scheme and propose a physical realization. It is shown that the inclusion of a counterintuitive laser field blocking the excited atoms on the left side of the device is essential for a perfect diode effect. The reason for this, the diodic behavior, and the robustness may be understood with an adiabatic approximation. The conditions to break down the approximation, which imply also the diode failure, are analyzed

  19. Iron-Doped Zinc Selenide: Spectroscopy and Laser Development

    Science.gov (United States)

    2014-03-27

    pulsed and CW platforms have been continuously tuned across the whole gain bandwidth of Cr:ZnSe using dispersive tuning elements [9, 13, 14]. Lasers...induced fluorescence studies of the upper state manifold of Fe:ZnSe. 3.2 Laser-Induced Fluorescence Spectroscoscopy of Fe:ZnSe A Cryo Industries of...that temperature was recorded to provide a basis for calculation of the spectral distribution of gain. The recorded spectrum was black- body

  20. Quasi-three-level thin-disk laser at 1024 nm based on diode-pumped Yb:YAG crystal

    International Nuclear Information System (INIS)

    Wang, A G; Li, Y L; Fu, X H

    2011-01-01

    We present for the first time, to the best of our knowledge, a Yb:YAG laser operating in a continuous wave (CW) on the quasi-three-level laser at 1024 nm, based on the 2 F 5/2 – 2 F 7/2 transition, generally used for a 1030 nm emission. The use of a pump module with 16 passes through the crystal allowed the realization of a Yb:YAG thin-disk laser with 370 mW of CW output power at 1024 nm. Moreover, intracavity second-harmonic generation (SHG) has also been achieved with a power of 45 mW at 512 nm by using a LiB 3 O 5 (LBO) nonlinear crystal

  1. Experimental test of a four-level kinetic model for excited-state intramolecular proton transfer dye lasers

    Energy Technology Data Exchange (ETDEWEB)

    Costela, A; Munnoz, J M; Douhal, A; Figuera, J M; Acuna, A U [Inst. de Quimica Fisica ' ' Rocasolano' ' , C.S.I.C., Madrid (Spain)

    1989-11-01

    The nanosecond pulses of a dye laser oscillator based on the excited-state intramolecular proton-transfer reaction (IPT) of salicylamide and 2'-hydroxylphenyl benzimidazole dyes have been studied as a function of several experimental parameters. To explain the operation of this laser a numerical four-level kinetic model was developed until the lasing properties of these dyes, in the presence of a variable oxygen concentration and pumped with a double pulse technique, could be reproduced. This was possible only by assuming that the efficiency of the laser is controlled by the absorption cross-section of a transient state with a lifetime in the nanosecond-picosecond range, which was tentatively identified as a ground state tautomeric species. (orig.).

  2. Prevention of pharyngocutaneous fistulas by means of laser-weld techniques.

    Science.gov (United States)

    Shohet, J A; Reinisch, L; Ossoff, R H

    1995-07-01

    Although much has been written on methods of dealing with pharyngocutaneous fistulas once they have formed, there are few reports of methods of preventing fistula formation from occurring. We examined the use of laser-weld techniques with the neodymium:yttrium aluminum garnet (Nd:YAG) and diode lasers to seal pharyngotomy closures. Laser-weld techniques have been used successfully in many other tissues, but reports documenting use in the upper aerodigestive tract are minimal. Indocyanine-green dye-enhanced collagen and fibrinogen were studied as laser solder materials for the diode laser. Twenty-nine experimental animals were studied. Neither the Nd:YAG nor the diode laser was successful in preventing fistula formation. Tensiometric studies documented significant strength of the laser welds ex vivo, but this finding was not clinically significant.

  3. The design and development of CO2 medium-level laser power calibration system for industrial and medical applications in Thailand

    Science.gov (United States)

    Nontapot, Kanokwan

    2018-03-01

    The carbon dioxide laser (CO2 laser) is one of the most useful and is the highest CW laser at the present. The laser produces infrared light at 10.6 um. Due to its high power, CO2 lasers are usually used in industrial applications such as cutting and welding, or for engraving at less power. CO2 lasers are also used widely in medical applications, such as laser surgery, skin resurfacing, and removing mold, due to water (biological tissue) absorb light at this wavelength very well. CO2 lasers are also used as LIDAR laser source for military range finding applications because of the transparency of the atmosphere to infrared light. Due to the increasing use of CO2 lasers laser in industrial and medical applications in Thailand, the National Institute of Metrology (Thailand) has set up a CO2 laser power calibration system and provide calibration service to customers this year. The service support calibration of medium-level laser power at wavelength of 10.6 um and at power range 100 mW-10W. The design and development of the calibration system will be presented.

  4. Level crossing statistics for optical beam wander in a turbulent atmosphere with applications to ground-to-space laser communications.

    Science.gov (United States)

    Yura, Harold T; Fields, Renny A

    2011-06-20

    Level crossing statistics is applied to the complex problem of atmospheric turbulence-induced beam wander for laser propagation from ground to space. A comprehensive estimate of the single-axis wander angle temporal autocorrelation function and the corresponding power spectrum is used to develop, for the first time to our knowledge, analytic expressions for the mean angular level crossing rate and the mean duration of such crossings. These results are based on an extension and generalization of a previous seminal analysis of the beam wander variance by Klyatskin and Kon. In the geometrical optics limit, we obtain an expression for the beam wander variance that is valid for both an arbitrarily shaped initial beam profile and transmitting aperture. It is shown that beam wander can disrupt bidirectional ground-to-space laser communication systems whose small apertures do not require adaptive optics to deliver uniform beams at their intended target receivers in space. The magnitude and rate of beam wander is estimated for turbulence profiles enveloping some practical laser communication deployment options and suggesting what level of beam wander effects must be mitigated to demonstrate effective bidirectional laser communication systems.

  5. Investigation of the Phenomenon of Propagated Sensation along the Channels in the Upper Limb Following Administration of Acupuncture and Mock Laser.

    Science.gov (United States)

    Razavy, Shohreh; Gadau, Marcus; Zhang, Shi Ping; Wang, Fu Chun; Bangrazi, Sergio; Berle, Christine; Harahap, Mahrita; Li, Tie; Li, Wei Hong; Zaslawski, Christopher

    2017-10-01

    Similar to De Qi psychophysical responses, propagated sensation along the channels (PSC) is considered an important phenomenon in traditional Chinese acupuncture. In acupuncture clinical trials, different acupuncture manipulation techniques are used to enhance the propagation of sensation along the channels to facilitate an optimum therapeutic result. To examine and compare the PSC reported by participants in a clinical trial following the administration of acupuncture and inactive mock laser. The study was embedded in a two-arm parallel design multicenter, randomized clinical trial, the Tennis Elbow Acupuncture-International Study-China, Hong Kong, Australia, Italy (TEA IS CHAI). Needle sensations were measured using a validated instrument, the Massachusetts General Hospital Acupuncture Sensation Spreading Scale. Ninety-six participants with lateral elbow pain were randomly allocated into two groups in a 1:1 ratio; the acupuncture treatment group (n = 47) and the mock laser control group (n = 49). Participants in both groups received the intervention at two acupoints, LI10 and LI11, consisting of 2 minutes of either standardized needle manipulation or mock laser at each acupoint with a rest period between each intervention period. Data were collected immediately following the interventions at the first and the ninth session within the clinical trial. Although participants in both groups perceived PSC radiating to similar sites along the upper limb, the frequency of the reported radiation sites among the two intervention groups for both radiation up the limb (p sensation sites recorded within the two study groups, the sensations were reported as radiating a greater distance down the forearm to the wrist compared to up the arm. Evaluation of PSC across the four study sites revealed a statistically significant difference in frequency of the reported radiation down the limb sites in each study group and radiation up the limb sites only in control group only (p

  6. Laser for fusion energy

    International Nuclear Information System (INIS)

    Holzrichter, J.F.

    1995-01-01

    Solid state lasers have proven to be very versatile tools for the study and demonstration of inertial confinement fusion principles. When lasers were first contemplated to be used for the compression of fusion fuel in the late 1950s, the laser output energy levels were nominally one joule and the power levels were 10 3 watts (pulse duration's of 10 -3 sec). During the last 25 years, lasers optimized for fusion research have been increased in power to typically 100,000 joules with power levels approaching 10 14 watts. As a result of experiments with such lasers at many locations, DT target performance has been shown to be consistent with high gain target output. However, the demonstration of ignition and gain requires laser energies of several megajoules. Laser technology improvements demonstrated over the past decade appear to make possible the construction of such multimegajoule lasers at affordable costs. (author)

  7. Oncoplastic Surgery for Upper/Upper Inner Quadrant Breast Cancer.

    Directory of Open Access Journals (Sweden)

    Joseph Lin

    Full Text Available Tumors located in the upper/upper inner quadrant of the breast warrant more attention. A small lesion relative to the size of breast in this location may be resolved by performing a level I oncoplastic technique. However, a wide excision may significantly reduce the overall quality of the breast shape by distorting the visible breast line. From June 2012 to April 2015, 36 patients with breast cancer located in the upper/upper inner quadrant underwent breast-conservation surgery with matrix rotation mammoplasty. According to the size and location of the tumor relative to the nipple-areola complex, 11 patients underwent matrix rotation with periareolar de-epithelialization (donut group and the other 25 underwent matrix rotation only (non-donut group. The cosmetic results were self-assessed by questionnaires. The average weights of the excised breast lumps in the donut and non-donut groups were 104.1 and 84.5 g, respectively. During the 3-year follow-up period, local recurrence was observed in one case and was managed with nipple-sparing mastectomy followed by breast reconstruction with prosthetic implants. In total, 31 patients (88.6% ranked their postoperative result as either acceptable or satisfactory. The treated breasts were also self-evaluated by 27 patients (77.1% to be nearly identical to or just slightly different from the untreated side. Matrix rotation is an easy breast-preserving technique for treating breast cancer located in the upper/upper inner quadrant of the breast that requires a relatively wide excision. With this technique, a larger breast tumor could be removed without compromising the breast appearance.

  8. Energy levels and far-infrared optical absorption of impurity doped semiconductor nanorings: Intense laser and electric fields effects

    Energy Technology Data Exchange (ETDEWEB)

    Barseghyan, M.G., E-mail: mbarsegh@ysu.am

    2016-11-10

    Highlights: • The electron-impurity interaction on energy levels in nanoring have been investigated. • The electron-impurity interaction on far-infrared absorption have been investigated. • The energy levels are more stable for higher values of electric field. - Abstract: The effects of electron-impurity interaction on energy levels and far-infrared absorption in semiconductor nanoring under the action of intense laser and lateral electric fields have been investigated. Numerical calculations are performed using exact diagonalization technique. It is found that the electron-impurity interaction and external fields change the energy spectrum dramatically, and also have significant influence on the absorption spectrum. Strong dependence on laser field intensity and electric field of lowest energy levels, also supported by the Coulomb interaction with impurity, is clearly revealed.

  9. Determining the Probability of Violating Upper-Level Wind Constraints for the Launch of Minuteman Ill Ballistic Missiles At Vandenberg Air Force Base

    Science.gov (United States)

    Shafer, Jaclyn A.; Brock, Tyler M.

    2013-01-01

    The 30th Operational Support Squadron Weather Flight (30 OSSWF) provides comprehensive weather services to the space program at Vandenberg Air Force Base (VAFB) in California. One of their responsibilities is to monitor upper-level winds to ensure safe launch operations of the Minuteman Ill ballistic missile. The 30 OSSWF requested the Applied Meteorology Unit (AMU) analyze VAFB sounding data to determine the probability of violating (PoV) upper-level thresholds for wind speed and shear constraints specific to this launch vehicle, and to develop a graphical user interface (GUI) that will calculate the PoV of each constraint on the day of launch. The AMU suggested also including forecast sounding data from the Rapid Refresh (RAP) model. This would provide further insight for the launch weather officers (LWOs) when determining if a wind constraint violation will occur over the next few hours, and help to improve the overall upper winds forecast on launch day.

  10. Reduction of Fermi level pinning and recombination at polycrystalline CdTe surfaces by laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Simonds, Brian J. [Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112 (United States); Kheraj, Vipul [Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112 (United States); Department of Applied Physics, S. V. National Institute of Technology, Surat 395 007 (India); Palekis, Vasilios; Ferekides, Christos [Electrical Engineering, University of South Florida, Tampa, Florida 33620 (United States); Scarpulla, Michael A., E-mail: scarpulla@eng.utah.edu [Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112 (United States); Materials Science and Engineering, University of Utah, Salt Lake City, Utah 84112 (United States)

    2015-06-14

    Laser processing of polycrystalline CdTe is a promising approach that could potentially increase module manufacturing throughput while reducing capital expenditure costs. For these benefits to be realized, the basic effects of laser irradiation on CdTe must be ascertained. In this study, we utilize surface photovoltage spectroscopy (SPS) to investigate the changes to the electronic properties of the surface of polycrystalline CdTe solar cell stacks induced by continuous-wave laser annealing. The experimental data explained within a model consisting of two space charge regions, one at the CdTe/air interface and one at the CdTe/CdS junction, are used to interpret our SPS results. The frequency dependence and phase spectra of the SPS signal are also discussed. To support the SPS findings, low-temperature spectrally-resolved photoluminescence and time-resolved photoluminescence were also measured. The data show that a modest laser treatment of 250 W/cm{sup 2} with a dwell time of 20 s is sufficient to reduce the effects of Fermi level pinning at the surface due to surface defects.

  11. An optical technique to measure the frequency and mode emission of tunable lasers

    International Nuclear Information System (INIS)

    Marchetti, S.; Simili, R.

    1988-01-01

    To use mode tunable lasers it is necessary to measure the laser frequency and the mode emission. This problem is very important when waveguide lasers are used. Normally this information is obtained by a heterodyne technique, but there are some difficulties to perform this method in a large electrical noise environment, when pulsed of radiofrequency lasers are used. This laser information was obtained by using an alternative low-cost optical system. With this apparatus the cavity pulling was measured and an upper limit for the linewidth of a radiofrequency, high pressure, line and mode-tunable, CO 2 laser was roughly estimated

  12. Over-expression of CXCR4, a stemness enhancer, in human blastocysts by low level laser irradiation

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Tahmasbi

    2013-09-01

    Full Text Available The key role of chemokine receptor CXCR4 in the maintenance of stemness property of stem cells has been shown recently. The low level laser irradiation (LLLI is being used currently in a wide variety of clinical cases as a therapeutic tool for wound healing, relieving pain and destroying tumor cells. The aim of this study was to evaluate the effect of LLLI mimicking low level laser therapy (LLLT on the expression level of CXCR4 gene a few hours after irradiation on human blastocysts. After the development of human embryos to the first grade blastocyst stage, they were irradiated with a low power Ga-Al-As laser at a continuous wavelength of 650 nm and a power output of 30 mW. The total RNA of the irradiated blastocysts and control groups were isolated in groups of 1x2 J/cm2, 2x2 J/cm2, 1x4 J/cm2 and 2x4 J/cm2 LLLI. Specific Real-Time PCR primers were designed to amplify all the two CXCR4 isoforms yet identified. RNA amplifications were done for all the groups. We showed for the first time that LLLI makes the human blastocysts to increase the expression level of CXCR4 a few hours after irradiation. Moreover, it was shown that two irradiation doses with one day interval can cause a significant increase in CXCR4 expression level in human blastocysts. This study revealed that LLLI could be a proliferation motivator for embryonic cell divisions through enhanced over-expression of CXCR4 level.

  13. Low-level laser treatment accelerated hair regrowth in a rat model of chemotherapy-induced alopecia (CIA).

    Science.gov (United States)

    Wikramanayake, Tongyu Cao; Villasante, Alexandra C; Mauro, Lucia M; Nouri, Keyvan; Schachner, Lawrence A; Perez, Carmen I; Jimenez, Joaquin J

    2013-05-01

    Chemotherapy-induced alopecia (CIA) is one of the most distressing side effects of antineoplastic chemotherapy for which there is no effective interventional approach. A low-level laser (LLL) device, the HairMax LaserComb®, has been cleared by the FDA to treat androgenetic alopecia. Its effects may be extended to other settings; we have demonstrated that LaserComb treatment induced hair regrowth in a mouse model for alopecia areata. In the current study, we tested whether LLL treatment could promote hair regrowth in a rat model for CIA. Chemotherapy agents cyclophosphamide, etoposide, or a combination of cyclophosphamide and doxorubicin were administered in young rats to induce alopecia, with or without LLL treatment. As expected, 7-10 days later, all the rats developed full body alopecia. However, rats receiving laser treatment regrew hair 5 days earlier than rats receiving chemotherapy alone or sham laser treatment (with the laser turned off). The accelerated hair regrowth in laser-treated rats was confirmed by histology. In addition, LLL treatment did not provide local protection to subcutaneously injected Shay chloroleukemic cells. Taken together, our results demonstrated that LLL treatment significantly accelerated hair regrowth after CIA without compromising the efficacy of chemotherapy in our rat model. Our results suggest that LLL should be explored for the treatment of CIA in clinical trials because LLL devices for home use (such as the HairMax LaserComb®) provide a user-friendly and noninvasive approach that could be translated to increased patient compliance and improved efficacy.

  14. Appraisal of economic impact of zero tillage, laser land levelling and bed-furrow interventions in punjab, pakistan

    International Nuclear Information System (INIS)

    Latif, A.; Shakir, A.S.

    2013-01-01

    irrigation is inevitable for profitable farming in arid and semi-arid regions. Water shortage is augmenting all over the world including Pakistan, due to which agriculture sector is facing critical challenges. For sustainable and feasible agriculture production, the cost of crop inputs needs to be reduced and at the same time the efficiency of resources must be enhanced. Resource conservation interventions (RCIs) play a vital role to achieve these goals. The RCIs include laser land levelling (LLL), zero tillage (ZT) and bed-furrow (BF). A survey was conducted in year 2011-12 in ten districts of Punjab for data collection regarding the agriculture inputs and outputs of RCIs and traditional irrigation system. The study area lies in rice-wheat cropping zone in Punjab, Pakistan. The analysis of data concluded that these interventions have enhanced the crop yield; saved significant irrigation water and increased the income of the farmers. Irrigation water saved by laser land levelling, zero tillage and bed-furrow was 31, 49 and 40 percent per hectare respectively in the selected irrigated areas. Water productivity was higher for zero tillage farms (2.02 kg/m/sup 3/) followed by bed-furrow (1.59 kg/m/sub 3/) and laser land levelling farms (1.58 kg/m/sub 3/). Fertilizer use efficiency by zero tillage, bed-furrow and laser land levelling was 19.1, 18.19 and 17.7 percent per hectare respectively as compared to traditional farming (13.98 percent). Therefore, the resource conservation interventions provide excellent tool for making development towards improving and sustaining agriculture production, ensure food security and poverty empowerment in Pakistan and elsewhere under similar socio-environmental conditions. (author)

  15. Serum of 25-Hydroxyvitamin D and Intact Parathyroid Hormone Levels in Postmenopausal Women with Hip and Upper Limb Fractures.

    Science.gov (United States)

    Lv, Jiang-Tao; Zhang, Ying-Ying; Tian, Shao-Qi; Sun, Kang

    2016-05-01

    To assess the serum of 25-hydroxyvitamin D (25(OH)D) and intact parathyroid hormone (iPTH) levels in postmenopausal women from northern China with hip and upper limb fractures. Case-control. Affiliated Hospital of Qingdao University. Postmenopausal women diagnosed with hip fracture (n = 335) and matched controls without fracture (n = 335). Between 2011 and 2013, fasting venous samples were analyzed for 25(OH)D, iPTH, alkaline phosphatase (ALP), calcium, and phosphorus. All women completed a standardized questionnaire designed to document putative risk factors for fractures. Eight percent of participants had vitamin D deficiency, and 66.0% had secondary hyperparathyroidism. Serum 25(OH)D levels were significantly (P lower in women with hip fracture than in controls. Multivariate logistic regression analysis adjusted for common risk factors showed that serum 25(OH)D of 20 ng/mL or less was an independent indicator of hip fracture (odds ratio (OR) = 2.98, 95% confidence interval (CI) = 2.11-4.20) and concomitant upper limb fracture in those with existing hip fractures (OR = 4.77, 95% CI = 1.60-10.12). The area under the receiver operating characteristic curve of 25(OH)D was 0.77 (95% CI = 0.68-0.84) for hip fracture and 0.80 (95% CI = 0.72-0.89) for hip and upper limb fractures. Vitamin D insufficiency and secondary hyperparathyroidism were a common problem in postmenopausal women who presented with concomitant hip and upper limb fractures, suggesting that they might contribute to the pathophysiology of fractures in postmenopausal women. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  16. Particle Generation by Laser Ablation in Support of Chemical Analysis of High Level Mixed Waste from Plutonium Production Operations

    International Nuclear Information System (INIS)

    Dickinson, J. Thomas; Alexander, Michael L.

    2001-01-01

    Investigate particles produced by laser irradiation and their analysis by Laser Ablation Inductively Coupled Plasma Mass Spectroscopy (LA/ICP-MS), with a view towards optimizing particle production for analysis of high level waste materials and waste glass. LA/ICP-MS has considerable potential to increase the safety and speed of analysis required for the remediation of high level wastes from cold war plutonium production operations. In some sample types, notably the sodium nitrate-based wastes at Hanford and elsewhere, chemical analysis using typical laser conditions depends strongly on the details of sample history composition in a complex fashion, rendering the results of analysis uncertain. Conversely, waste glass materials appear to be better behaved and require different strategies to optimize analysis

  17. Evaluation of Oral Mucositis Occurrence in Oncologic Patients under Antineoplastic Therapy Submitted to the Low-Level Laser Coadjuvant Therapy.

    Science.gov (United States)

    Leite Cavalcanti, Alessandro; José de Macêdo, Dário; Suely Barros Dantas, Fernanda; Dos Santos Menezes, Karla; Filipe Bezerra Silva, Diego; Alves de Melo Junior, William; Fabia Cabral Cavalcanti, Alidianne

    2018-04-24

    Low-level laser therapy has been widely used in treating many conditions, including oral mucositis. The purpose of this study was to evaluate the occurrence of oral mucositis in patients undergoing antineoplastic therapy submitted to preventive and therapeutic treatment with low-level laser therapy. This cross-sectional study was carried out with 51 children and adolescents of both sexes with malignant neoplasias who developed oral mucositis and underwent low-level laser therapy. Data were collected on sex, age, type and degree of neoplasia, region affected, and remission time. 64.7% of the patients were male and were between 3 and 6 years of age (39.2%). Acute lymphoid leukemia was the most frequent neoplasm (37.3%). Regarding the maximum oral mucositis, grade 2 (41.2%) was predominant, with jugal mucosa (29.9%) and tongue (17.7%) being the most affected regions. The majority of cases presented lesion remission time between 4 and 7 days (44.0%). Most patients were young, male, and diagnosed with acute lymphoid leukemia. Predominance of grade 2 oral mucositis was observed, with jugal mucosa and tongue being the most affected regions, with the majority of cases presenting lesion remission time between 4 and 7 days. Low-level laser therapy has been shown to be an essential therapy in the prevention and treatment of these lesions, since it is a non-invasive and low-cost method.

  18. Effect of low-level laser therapy after extraction of impacted lower third molars.

    Science.gov (United States)

    Ferrante, Maurizio; Petrini, Morena; Trentini, Paolo; Perfetti, Giorgio; Spoto, Giuseppe

    2013-05-01

    The aim of this study is to evaluate the effectiveness of the low-level laser therapy (LLLT) in the control of pain, swelling, and trismus associated with surgical removal of impacted lower third molars. Thirty patients were randomized into two treatment groups, each with 15 patients-group test (LLLT) and a group control (no-LLLT)-and were told to avoid any analgesics 12 h before the procedure. In group test, the 980-nm diode-laser (G-Laser 25 Galbiati, Italy) was applied, using a 600-μm handpiece, intraorally (lingual and vestibular) at 1 cm from the involved area and extraoral at the insertion point of the masseter muscle immediately after surgery and at 24 h. The group control received only routine management. Parameters used for LLLT were: continuous mode, at 300 mW (0.3 W) for a total of 180 s (60 s × 3) (0.3 W × 180 s=54 J). Group test showed improvement in the interincisal opening and remarkable reduction of trismus, swelling and intensity of pain on the first and the seventh postoperative days. Although LLLT has been reported to prevent swelling and trismus following the removal of impacted third molars, some of these studies reported a positive laser effect while others did not. All references to the use of laser therapy in the postoperative management of third molar surgery employ different methodologies and, in some, explanations as to selection of their respective radiation parameters are not given. This study has demonstrated that LLLT, with these parameters, is useful for the reduction of postoperative discomfort after third-molar surgery.

  19. The effect of diode laser and topical steroid on serum level of TNF-alpha in oral lichen planus patients.

    Science.gov (United States)

    Othman, Nagwa-Abdelhamid; Shaker, Olfat-Gamil; Elshenawy, Hanaa-Mohamed; Abd-Elmoniem, Wessam; Eldin, Amany-Mohy; Fakhr, Mariam-Yehia

    2016-12-01

    Oral lichen planus (OLP) is a common chronic inflammatory mucosal disease with a multifactorial etiology. It is a T-cell mediated autoimmune disease in which the cytotoxic CD8+T cells trigger apoptosis of the basal cells of oral epithelium. Various treatment regimens have been employed for management of symptomatic OLP. This study was carried out to evaluate the effect of topical steroids as well as laser on the clinical signs and symptoms detected by reticular, atrophic, erosive score (RAE score) and tumor necrosis factor- α (TNF-α) level in the serum of patients with symptomatic OLP. The study was conducted on twenty-four patients (18 females and 6 males) with symptomatic OLP that were allocated into two groups. Each included twelve patients. The first group treated either with diode laser (970nm SIROLaser Advance class IIIb, SIRONA The Dental Company, Germany) twice weekly with maximum of ten sessions while the second group were treated with topical corticosteroids (0.1% triamcinolone acetonide orabase, Kenacort-A Orabase Pomad, DEVA HOLDING A.Ș, Istanbul, Turkey) for four weeks. Corticosteroids group showed less clinical signs and symptoms of reticular, atrophic, erosive RAE score ( p =0.02) and TNF-α serum level ( p =0.028) than diode laser group with no reported therapy side effects or complications in any of the treated patients. Topical steroids reduce pain, reticular, atrophic, erosive RAE score and TNF-α serum level more than laser treatment. Moreover, laser treatment can be used as an alternative treatment when steroids are contraindicated for the treatment of symptomatic OLP. Key words: Oral lichen planus, diode laser, topical steroid, RAE score, TNF-α.

  20. Lande gJ factors for even-parity electronic levels in the holmium atom

    Science.gov (United States)

    Stefanska, D.; Werbowy, S.; Krzykowski, A.; Furmann, B.

    2018-05-01

    In this work the hyperfine structure of the Zeeman splitting for 18 even-parity levels in the holmium atom was investigated. The experimental method applied was laser induced fluorescence in a hollow cathode discharge lamp. 20 spectral lines were investigated involving odd-parity levels from the ground multiplet, for which Lande gJ factors are known with high precision, as the lower levels; this greatly facilitated the evaluation of gJ factors for the upper levels. The gJ values for the even-parity levels considered are reported for the first time. They proved to compare fairly well with the values obtained recently in a semi-empirical analysis for the even-parity level system of Ho I.

  1. Excitonic bistabilities, instabilities and chaos in laser-pumped semiconductor

    International Nuclear Information System (INIS)

    Nguyen Ba An; Nguyen Trung Dan; Hoang Xuan Nguyen

    1992-07-01

    The Hurwitz criteria are used for a stability analysis of the steady state excitonic optical bistability curves in a semiconductor pumped by an external laser resonant with the exciton level. Besides the middle branch of the bistability curves which is unstable in the sense of the linear stability theory, we have found other domains of instability in the upper and lower branches of the steady state curves. Numerical results show that a possible route to chaos in the photon-exciton system is period-doubling self-oscillation process. The influence of the presence of free carriers that coexist with the excitons is also discussed. (author). 16 refs, 6 figs

  2. Determination of Lande gJ - factors of La I levels using laser spectroscopic methods: Complementary investigations

    Science.gov (United States)

    Sobolewski, Ł. M.; Windholz, L.; Kwela, J.

    2017-11-01

    Laser Induced Fluorescence Spectroscopy (LIF) and Optogalvanic Spectroscopy (OG) were used for the investigation of the Zeeman hyperfine structures of 26 spectral lines of La I in the wavelength range between 569.7 and 665.4 nm. As a source of free La atoms a hollow cathode discharge lamp was used. The spectra were recorded in the presence of a magnetic field of about 800G produced by a permanent magnet for two linear polarizations of the exciting laser light. As a result of the study, we determined for the first time the Landé gJ- factors of 20 levels of La I. For several other levels the Landé gJ- factors were re-investigated and determined with higher precision.

  3. Effect of low-level laser on healing of temporomandibular joint osteoarthritis in rats.

    Directory of Open Access Journals (Sweden)

    Ali Peimani

    2014-06-01

    Full Text Available Temporomandibular disorders (TMD are clinical conditions characterized by pain and sounds of the temporomandibular joint (TMJ. This study was designed to assess the effect of low-level laser therapy (LLLT on healing of osteoarthritis in rats with TMD.Thirty-two male Wistar rats (250-200 g were housed in standard plastic cages. After injection of Complete Freund's adjuvant into the TMJ, rats were randomly divided into two groups of 16 (case and control and anesthetized; then osteoarthritis was induced via intraarticular injection of 50 µl of Complete Freund's adjuvant; into the bilateral TMJs. In the case group, LLLT was done transcutaneously for 10 minutes daily, starting the day after the confirmation of osteoarthritis. Exposure was performed for 10 minutes at the right side of the TMJ with 880 nm low-level laser with 100 mW power and a probe diameter of 0.8 mm. Control rats were not treated with laser.After three days of treatment the grade of cartilage defects, number of inflammatory cells, angiogenesis, number of cell layers and arthritis in rats in the case group were not significantly different compared with controls (P>0.05. After seven days, the grade of cartilage defects, number of inflammatory cells, number of cell layers, and arthritis in the case group improved compared to controls (P<0.05; angiogenesis in both groups was similar.Treatment of TMD with LLLT after 7 days of irradiation with a wavelength of 880 nm was associated with a greater improvement compared to the control group.

  4. Comparison of anthropometry, upper-body strength, and lower-body power characteristics in different levels of Australian football players.

    Science.gov (United States)

    Bilsborough, Johann C; Greenway, Kate G; Opar, David A; Livingstone, Steuart G; Cordy, Justin T; Bird, Stephen R; Coutts, Aaron J

    2015-03-01

    The aim of this study was to compare the anthropometry, upper-body strength, and lower-body power characteristics in elite junior, sub-elite senior, and elite senior Australian Football (AF) players. Nineteen experienced elite senior (≥4 years Australian Football League [AFL] experience), 27 inexperienced elite senior (free soft tissue mass [FFSTM], fat mass, and bone mineral content) with dual-energy x-ray absorptiometry, upper-body strength (bench press and bench pull), and lower-body power (countermovement jump [CMJ] and squat jump with 20 kg). A 1-way analysis of variance assessed differences between the playing levels in these measures, whereas relationships between anthropometry and performance were assessed with Pearson's correlation. The elite senior and sub-elite senior players were older and heavier than the elite junior players (p ≤ 0.05). Both elite playing groups had greater total FFSTM than both the sub-elite and junior elite players; however, there were only appendicular FFSTM differences between the junior elite and elite senior players (p squat performance measures (r = 0.33-0.55). Australian Football players' FFSTM are different between playing levels, which are likely because of training and partly explain the observed differences in performance between playing levels highlighting the importance of optimizing FFSTM in young players.

  5. Effect of Low-Level Laser therapy on the fungal proliferation of Candida albicans

    Science.gov (United States)

    Carneiro, Vanda S. M.; Araújo, Natália C.; Menezes, Rebeca F. d.; Moreno, Lara M.; Santos-Neto, Alexandrino d. P.; Gerbi, Marleny Elizabeth M.

    2016-03-01

    Candida albicans plays an important role in triggering infections in HIV+ patients. The indiscriminate use of antifungals has led to resistance to Candida albicans, which requires new treatment alternatives for oral candidiasis. Low-level laser therapy promotes a considerable improvement in the healing of wounds and in curing illnesses caused by microorganisms. The aim of the present study was to assess the effect of laser radiation on the cell proliferation of Candida albicans in immunosuppressed patients. Six Candida albicans strains that had been isolated from immunosuppressed patients were divided into a control group and experimental groups, which received eight sessions of laser therapy (InGaAlP, λ685nm, P = 30mW, CW, Φ~6 mm and GaAlAs, λ830nm, P = 40mW, CW, Φ~6 mm) using dosimetries of 6J/cm2, 8J/cm2, 10J/cm2 and 12J/cm2 for each wavelength and power. The results were not statistically significant (Kruskal Wallis, p > 0.05), although the proliferation of Candida albicans was lower in some of the experimental groups. The dosimetry of 6J/cm2 (GaAlAs, λ830nm, P = 40mW) provided lower mean scores than the other groups for the growth of Candida. Further studies are required to confirm whetehr laser therapy is a viable option in the treatment of fungal infections.

  6. The effects of low level laser therapy on both HIV-1 infected and uninfected TZM-bl cells

    CSIR Research Space (South Africa)

    Lugongolo, Masixole Y

    2017-01-01

    Full Text Available that would completely eradicate the virus in infected individuals, the quest for new therapies continues. Low level laser therapy (LLLT) involves the exposure of cells to low levels of red or infrared light. LLLT has been widely used in different medical...

  7. Skin optical clearing for improvement of laser tattoo removal

    Science.gov (United States)

    Bashkatov, A. N.; Genina, E. A.; Tuchin, V. V.; Altshuler, G. B.

    2009-06-01

    The possibility of improvement of laser tattoo removal due to the optical clearing of human skin is investigated. It is shown experimentally that previously perforation of skin stratum corneum allows increasing tattoo image contrast at topical administration of immersion agent in contrast with non-perforated skin. Computer Monte Carlo simulation shows that at the optical clearing of upper skin layers the tattoo image contrast and the photon fraction absorbed in the tattoo area at the depths of 0.5 or 1.0 mm increase, that allows significant decreasing of the power of laser radiation used at laser thermolysis.

  8. Assessment of Mismatch at Indicated Level of the Upper Side Zone of LZC on abnormal operations

    International Nuclear Information System (INIS)

    Kim, Sung-Min; Park, Joong-Woo; Kho, Dae-Hack; Seo, Hyung-Beom; Han, Bong-Gyun; Moon, Jin-Soo

    2006-01-01

    Liquid Zone Control System of CANDU reactor provides bulk and spatial control. This system has produced abnormal operations with water level increase due to refueling since 1998. The abnormal operations of LZC system at Wolsong 2 can be divided into two periods. One is the sudden drop with continuous operation mode of LZC compressor and the other one is cycling with the on-off operation mode of the LZC compressor. It is identified through the communication with other CANDU reactors that this phenomenon is not unique to Wolsong. Whenever the upper side zone (1,8,6,13) level exceeded 80%, these abnormal operations occurred and mismatch between indicated and actual zone level was found. Counter-plan is prepared to ease these abnormal operations by physicist own efforts at Wolsong 2

  9. Analysis of a 10 megawatt space-based solar-pumped neodymium laser system

    Science.gov (United States)

    Kurweg, U. H.

    1984-01-01

    A ten megawatt solar-pumped continuous liquid laser system for space applications is examined. It is found that a single inflatable mirror of 434 m diameter used in conjunction with a conical secondary concentrator is sufficient to side pump a liquid neodymium lasant in an annular tube of 6 m length and 1 m outer and 0.8 m inner diameter. About one fourth of intercepted radiation converging on the laser tube is absorbed and one fifth of this radiation is effective in populating the upper levels. The liquid lasant is flowed through the annular laser cavity at 1.9 m/s and is cooled via a heat exchanger and a large radiator surface comparable in size to the concentrating mirror. The power density of incident light within the lasant of approximately 68 watt/cu cm required for cw operation is exceeded in the present annular configuration. Total system weight corresponds to 20,500 kg and is thus capable of being transported to near Earth orbit by a single shuttle flight.

  10. Evaluation of low-level laser therapy in the treatment of masticatory muscles spasticity in children with cerebral palsy

    Science.gov (United States)

    Santos, Maria Teresa Botti Rodrigues; Diniz, Michele Baffi; Gouw-Soares, Sheila Cynthia; Lopes-Martins, Rodrigo Alvaro Brandão; Frigo, Lucio; Baeder, Fernando Martins

    2016-02-01

    Spasticity is a motor disorder frequently present in individuals with cerebral palsy (CP). This study aimed to evaluate the effect of low-level laser therapy (LLLT) on the spasticity of the masseter and anterior temporal muscle fibers in children with CP over three weeks of intermittent laser exposures. The bite force (BF) of the masticatory muscles and the amplitude of mouth opening were evaluated before and after laser irradiation in 30 children with CP. Both sides of the masseter and temporalis muscles were irradiated with low-intensity diode laser pulses of 808-nm wavelength six times over three consecutive weeks. During the subsequent three weeks of postlaser exposures, although no laser treatment was applied, the evaluation parameters were measured and recorded. A significant improvement in the amplitude of mouth opening and a decrease in the BF were observed in the weeks following LLLT (Peffective short-term therapeutic tool. This method increased the amplitude of mouth opening and decreased the muscle tonus of children with spastic CP over a time course of three weeks of intermittent laser applications.

  11. Effects of polarization in low-level laser therapy of spinal cord injury in rats

    Science.gov (United States)

    Ando, Takahiro; Sato, Shunichi; Kobayashi, Hiroaki; Nawashiro, Hiroshi; Ashida, Hiroshi; Hamblin, Michael R.; Obara, Minoru

    2012-03-01

    Low-level laser therapy (LLLT) is a promising approach to treat the spinal cord injury (SCI). Since nerve fibers have optical anisotropy, propagation of light in the spinal tissue might be affected by its polarization direction. However, the effect of polarization on the efficacy of LLLT has not been elucidated. In the present study, we investigated the effect of polarization on the efficacy of near-infrared LLLT for SCI. Rat spinal cord was injured with a weight-drop device. The lesion site was irradiated with an 808-nm diode laser beam that was transmitted through a polarizing filter immediately after injury and daily for five consecutive days. The laser power at the injured spinal cord surface was 25 mW, and the dosage per day was 9.6 J/cm2 (spot diameter, 2 cm; irradiation duration, 1200 s). Functional recovery was assessed daily by an open-field test. The results showed that the functional scores of the SCI rats that were treated with 808-nm laser irradiation were significantly higher than those of the SCI alone group (Group 1) from day 5 after injury, regardless of the polarization direction. Importantly, as compared to the locomotive function of the SCI rats that were treated with the perpendicularly-polarized laser parallel to the spinal column (Group 2), that of the SCI rats that were irradiated with the linearly aligned polarization (Group 3) was significantly improved from day 10 after injury. In addition, the ATP contents in the injured spinal tissue of Group 3, which were measured immediately after laser irradiation, were moderately higher than those of Group 2. These observations are attributable to the deeper penetration of the parallelpolarized light in the anisotropic spinal tissue, suggesting that polarization direction significantly affects the efficacy of LLLT for SCI.

  12. Laser pumped lasers for isotope separation

    International Nuclear Information System (INIS)

    Fry, S.M.

    1976-01-01

    A study of the isotope separation laser requirements reveals that high pressure polyatomic molecular gas laser pumped lasers can attain the necessary characteristics including tunability, energy output, pulse width, and repetition rate. The results of a search, made for molecules meeting the appropriate requirements for one of several pump schemes utilizing a CO 2 laser and with output in the 12 μm or 16μm wavelength range, are presented. Several methods of pumping are reviewed and two novel pump schemes are presented. A laser pumped laser device design is given, and operation of this device and associated diagnostic equipment is confirmed by repeating experiments in OCS and NH 3 . The results of OCS laser experiments show that an improvement in pump rate and output per unit length is obtained with the device, using a wedged transverse pumping scheme. A new multi-line laser system in NH 3 pumped by a TEA CO 2 laser is reported. More than forty transitions spanning the wavelength range of 9.2 to 13.8 μm are observed and identified. A strong output at 12.08 μm is one of the closest lines yet found to the required laser isotope separation wavelength. Far infrared emission near 65 μm is observed and is responsible for populating levels which lase in pure ammonia near 12.3 μm. Buffer gas (e.g., N 2 or He) pressures of approximately 40--800 torr cause energy transfer by collision-induced rotationaltransitions from the pumped antisymmetric to the lasing symmetric levels in the nu 2 = 1 band of ammonia. Most of the observed lines are aP(J,K) transitions which originate from the nu 2 /sup s/ band. Measurements of the pressure dependence of the laser output shows that some lines lase at pressures greater than one atmosphere. Transient behavior of the 12.08 μm line is calculated from a simplified analytic model and these calculations are compared to the experimental results

  13. INFLUENCE OF SNOWFALL ON BLOOD LEAD LEVELS OF FREE-FLYING BALD EAGLES (HALIAEETUS LEUCOCEPHALUS) IN THE UPPER MISSISSIPPI RIVER VALLEY.

    Science.gov (United States)

    Lindblom, Ronald A; Reichart, Letitia M; Mandernack, Brett A; Solensky, Matthew; Schoenebeck, Casey W; Redig, Patrick T

    2017-10-01

    Lead poisoning of scavenging raptors occurs primarily via consumption of game animal carcasses containing lead, which peaks during fall firearm hunting seasons. We hypothesized that snowfall would mitigate exposure by concealing carcasses. We categorized blood lead level (BLL) for a subsample of Bald Eagles (Haliaeetus leucocephalus) from the Upper Mississippi River Valley and described BLL with respect to age, sex, and snowfall. We captured Bald Eagles overwintering in the Upper Mississippi River Valley (n=55) between December 1999 and January 2002. Individual BLL ranged from nondetectable to 335 μg/dL, with 73% of the samples testing positive for acute exposure to lead. Eagle BLL did not significantly differ between age or sex, but levels were higher immediately following the hunting season, and they were lower when the previous month's snowfall was greater than 11 cm. This study suggests a window of time between the white-tailed deer (Odocoileus virginianus) hunting season and the onset of snow when the population experienced peak exposure to lead. Combining these findings with existing research, we offer a narrative of the annual lead exposure cycle of Upper Mississippi River Valley Bald Eagles. These temporal associations are necessary considerations for accurate collection and interpretation of BLL.

  14. Interpretation of Upper-Storey Canopy Area in Subtropical Broad-leaved Forests in Okinawa Island Using Laser Scanning Data

    International Nuclear Information System (INIS)

    Noor Janatun Naim Jemali; Shiba, M.; Azita Ahmad Zawawi; Noor Janatun Naim Jemali

    2015-01-01

    Conventional forest inventory practice took huge of effort, and is time- and cost- consuming. With the aid of remote sensing technology by light detection and ranging (LiDAR), those unbearable factors could be minimized. LiDAR is able to capture forest characteristic information and is well known for estimating forest structure accurately in many studies. Forest monitoring related to forest resource inventory (FRI) becomes more effective by utilizing LiDAR data and it is tremendously useful, especially to distinguish information on density, growth and distribution of trees in a selected area. In this study, LiDAR data was utilized aimed to delineate crown cover and estimate upper-storey canopy area in Yambaru Forest using object-based segmentation and classification techniques. Agreement between field survey and LiDAR data analysis showed that only 33.7 % of upper-storey canopy area was successfully delineated. The low accuracy level of canopy detection in Yambaru Forest area was expected mainly due to tree structure, density and topographic condition. (author)

  15. Upper limb injury in rugby union football: results of a cohort study.

    Science.gov (United States)

    Usman, Juliana; McIntosh, Andrew Stuart

    2013-04-01

    There have been few in-depth studies of upper limb injury epidemiology in rugby union football, despite reports that they accounted for between 14% and 28% of all rugby injuries. To report on upper limb injury incidence, injury severity and to identify the risk factors associated with upper limb injuries, for example, level of play, season (years) and playing position. Prospective cohort study across five rugby seasons from 2004 to 2008. Formal rugby competitions-suburban, provincial and international. 1475 adult male rugby players in Colts, Grade and Elite competitions. An upper limb injury resulting in a missed game and its characteristics. A total of 61 598 athletic exposures (AE) and 606 upper limb injuries were recorded. About 66% of the injuries were to the shoulder. The overall upper limb injury incidence rate (IIR) was 9.84 injuries/1000 AE (95% CI 9.06 to 10.62). Statistically significant associations were found between upper limb injuries and level of play; and between shoulder injuries and playing position (p<0.05). No association was found between upper limb and shoulder injuries and study year. The overall upper limb IIR decreased as the level of play increased; 10.74 upper limb injuries/1000 AE (95% CI 9.93 to 11.56) in Colts to 6.07 upper limb injuries/1000 AE (95% CI 5.46 to 6.69) in Elite. The upper limb IIR decreased as the level of play increased indicating that age, level of skill and playing experience may be risk factors for upper limb injury.

  16. Effect of low-level laser treatment on cochlea hair-cell recovery after ototoxic hearing loss

    Science.gov (United States)

    Rhee, Chung-Ku; He, Peijie; Jung, Jae Yun; Ahn, Jin-Chul; Chung, Phil-Sang; Lee, Min Young; Suh, Myung-Whan

    2013-12-01

    The primary cause of hearing loss includes damage to cochlear hair cells. Low-level laser therapy (LLLT) has become a popular treatment for damaged nervous systems. Based on the idea that cochlea hair cells and neural cells are from same developmental origin, the effect of LLLT on hearing loss in animal models is evaluated. Hearing loss animal models were established, and the animals were irradiated by 830-nm diode laser once a day for 10 days. Power density of the laser treatment was 900 mW/cm2, and the fluence was 162 to 194 J. The tympanic membrane was evaluated after LLLT. Thresholds of auditory brainstem responses were evaluated before treatment, after gentamicin, and after 10 days of LLLT. Quantitative scanning electron microscopic (SEM) observations were done by counting remaining hair cells. Tympanic membranes were intact at the end of the experiment. No adverse tissue reaction was found. On SEM images, LLLT significantly increased the number of hair cells in middle and basal turns. Hearing was significantly improved by laser irradiation. After LLLT treatment, both the hearing threshold and hair-cell count significantly improved.

  17. Evaluation of Oral Mucositis Occurrence in Oncologic Patients under Antineoplastic Therapy Submitted to the Low-Level Laser Coadjuvant Therapy

    Directory of Open Access Journals (Sweden)

    Alessandro Leite Cavalcanti

    2018-04-01

    Full Text Available Low-level laser therapy has been widely used in treating many conditions, including oral mucositis. The purpose of this study was to evaluate the occurrence of oral mucositis in patients undergoing antineoplastic therapy submitted to preventive and therapeutic treatment with low-level laser therapy. This cross-sectional study was carried out with 51 children and adolescents of both sexes with malignant neoplasias who developed oral mucositis and underwent low-level laser therapy. Data were collected on sex, age, type and degree of neoplasia, region affected, and remission time. 64.7% of the patients were male and were between 3 and 6 years of age (39.2%. Acute lymphoid leukemia was the most frequent neoplasm (37.3%. Regarding the maximum oral mucositis, grade 2 (41.2% was predominant, with jugal mucosa (29.9% and tongue (17.7% being the most affected regions. The majority of cases presented lesion remission time between 4 and 7 days (44.0%. Most patients were young, male, and diagnosed with acute lymphoid leukemia. Predominance of grade 2 oral mucositis was observed, with jugal mucosa and tongue being the most affected regions, with the majority of cases presenting lesion remission time between 4 and 7 days. Low-level laser therapy has been shown to be an essential therapy in the prevention and treatment of these lesions, since it is a non-invasive and low-cost method.

  18. Estimation of the Maximum Output Power of Double-Clad Photonic Crystal Fiber Laser

    International Nuclear Information System (INIS)

    Chen Yue-E; Wang Yong; Qu Xi-Long

    2012-01-01

    Compared with traditional optical fiber lasers, double-clad photonic crystal fiber (PCF) lasers have larger surface-area-to-volume ratios. With an increase of output power, thermal effects may severely restrict output power and deteriorate beam quality of fiber lasers. We utilize the heat-conduction equations to estimate the maximum output power of a double-clad PCF laser under natural-convection, air-cooling, and water-cooling conditions in terms of a certain surface-volume heat ratio of the PCF. The thermal effects hence define an upper power limit of double-clad PCF lasers when scaling output power. (fundamental areas of phenomenology(including applications))

  19. The effect of low level laser on anaplastic thyroid cancer

    Science.gov (United States)

    Rhee, Yun-Hee; Moon, Jeon-Hwan; Ahn, Jin-Chul; Chung, Phil-Sang

    2015-02-01

    Low-level laser therapy (LLLT) is a non-thermal phototherapy used in several medical applications, including wound healing, reduction of pain and amelioration of oral mucositis. Nevertheless, the effects of LLLT upon cancer or dysplastic cells have been so far poorly studied. Here we report that the effects of laser irradiation on anaplastic thyroid cancer cells leads to hyperplasia. 650nm of laser diode was performed with a different time interval (0, 15, 30, 60J/cm2 , 25mW) on anaplastic thyroid cancer cell line FRO in vivo. FRO was orthotopically injected into the thyroid gland of nude mice and the irradiation was performed with the same method described previously. After irradiation, the xenograft evaluation was followed for one month. The thyroid tissues from sacrificed mice were undergone to H&E staining and immunohistochemical staining with HIF-1α, Akt, TGF-β1. We found the aggressive proliferation of FRO on thyroid gland with dose dependent. In case of 60 J/ cm2 of energy density, the necrotic bodies were found in a center of the thyroid. The phosphorylation of HIF-1α and Akt was detected in the thyroid gland, which explained the survival signaling of anaplastic cancer cell was turned on the thyroid gland. Furthermore, TGF-β1 expression was decreased after irradiation. In this study, we demonstrated that insufficient energy density irradiation occurred the decreasing of TGF-β1 which corresponding to the phosphorylation of Akt/ HIF-1α. This aggressive proliferation resulted to the hypoxic condition of tissue for angiogenesis. We suggest that LLLT may influence to cancer aggressiveness associated with a decrease in TGF-β1 and increase in Akt/HIF-1α.

  20. Biological effects of low-level laser irradiation on umbilical cord mesenchymal stem cells

    International Nuclear Information System (INIS)

    Chen, Hongli; Wang, Hong; Li, Yingxin; Liu, Weichao; Chen, Zhuying; Wang, Chao

    2016-01-01

    Low-level laser irradiation (LLLI) can enhance stem cell (SC) activity by increasing migration and proliferation. This study investigated the effects of LLLI on proliferation, enzymatic activity, and growth factor production in human umbilical cord mesenchymal SCs (hUC-MSCs) as well as the underlying mechanisms. hUC-MSCs were assigned to a control group (non-irradiation group) and three LLLI treatment groups (635 nm group, 808 nm group, and 635/808 nm group). Laser power density and energy density of 20 mW/cm"2 and 12 J/cm"2, respectively, were used for each experiment. The proliferation rate was higher in the 635 nm as compared to the other groups. LLLI at 808 nm did not induce cell proliferation. ROS levels in cells exposed to 635, 808, and 635/808 nm radiation were increased by 52.81%, 26.89%, and 21.15%, respectively, relative to the control group. CAT, tGPx, and SOD activity was increased. LLLI at 808 nm increased the levels of IL-1, IL-6, and NFκB but not VEGF. LLLI improved hUC-MSCs function and increased antioxidant activity. Dual-wavelength LLLI had more potent effects on hUC-MSCs than single-wavelength treatment. LLLI has potential applications in the preconditioning of hUC-MSCs in vitro prior to transplantation, which could improve the regenerative capacity of cells.

  1. Biological effects of low-level laser irradiation on umbilical cord mesenchymal stem cells

    Science.gov (United States)

    Chen, Hongli; Wang, Hong; Li, Yingxin; Liu, Weichao; Wang, Chao; Chen, Zhuying

    2016-04-01

    Low-level laser irradiation (LLLI) can enhance stem cell (SC) activity by increasing migration and proliferation. This study investigated the effects of LLLI on proliferation, enzymatic activity, and growth factor production in human umbilical cord mesenchymal SCs (hUC-MSCs) as well as the underlying mechanisms. hUC-MSCs were assigned to a control group (non-irradiation group) and three LLLI treatment groups (635 nm group, 808 nm group, and 635/808 nm group). Laser power density and energy density of 20 mW/cm2 and 12 J/cm2, respectively, were used for each experiment. The proliferation rate was higher in the 635 nm as compared to the other groups. LLLI at 808 nm did not induce cell proliferation. ROS levels in cells exposed to 635, 808, and 635/808 nm radiation were increased by 52.81%, 26.89%, and 21.15%, respectively, relative to the control group. CAT, tGPx, and SOD activity was increased. LLLI at 808 nm increased the levels of IL-1, IL-6, and NFκB but not VEGF. LLLI improved hUC-MSCs function and increased antioxidant activity. Dual-wavelength LLLI had more potent effects on hUC-MSCs than single-wavelength treatment. LLLI has potential applications in the preconditioning of hUC-MSCs in vitro prior to transplantation, which could improve the regenerative capacity of cells.

  2. Biological effects of low-level laser irradiation on umbilical cord mesenchymal stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Hongli; Wang, Hong; Li, Yingxin, E-mail: yingxinli2005@126.com; Liu, Weichao; Chen, Zhuying [Key Laboratory of Laser Medicine of Tianjin, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192 (China); Wang, Chao [Biomedical Engineering and Technology College, Tianjin Medical University, Tianjin, 300070 (China)

    2016-04-15

    Low-level laser irradiation (LLLI) can enhance stem cell (SC) activity by increasing migration and proliferation. This study investigated the effects of LLLI on proliferation, enzymatic activity, and growth factor production in human umbilical cord mesenchymal SCs (hUC-MSCs) as well as the underlying mechanisms. hUC-MSCs were assigned to a control group (non-irradiation group) and three LLLI treatment groups (635 nm group, 808 nm group, and 635/808 nm group). Laser power density and energy density of 20 mW/cm{sup 2} and 12 J/cm{sup 2}, respectively, were used for each experiment. The proliferation rate was higher in the 635 nm as compared to the other groups. LLLI at 808 nm did not induce cell proliferation. ROS levels in cells exposed to 635, 808, and 635/808 nm radiation were increased by 52.81%, 26.89%, and 21.15%, respectively, relative to the control group. CAT, tGPx, and SOD activity was increased. LLLI at 808 nm increased the levels of IL-1, IL-6, and NFκB but not VEGF. LLLI improved hUC-MSCs function and increased antioxidant activity. Dual-wavelength LLLI had more potent effects on hUC-MSCs than single-wavelength treatment. LLLI has potential applications in the preconditioning of hUC-MSCs in vitro prior to transplantation, which could improve the regenerative capacity of cells.

  3. Low level laser therapy for patients with cervical disk hernia.

    Science.gov (United States)

    Takahashi, Hiroshi; Okuni, Ikuko; Ushigome, Nobuyuki; Harada, Takashi; Tsuruoka, Hiroshi; Ohshiro, Toshio; Sekiguchi, Masayuki; Musya, Yoshiro

    2012-09-30

    In previous studies we have reported the benefits of low level laser therapy (LLLT) for chronic shoulder joint pain, elbow, hand and finger pain, and low back pain. The present study is a report on the effects of LLLT for chronic neck pain. Over a 3 year period, 26 rehabilitation department outpatients with chronic neck pain, diagnosed as being caused by cervical disk hernia, underwent treatment applied to the painful area with a 1000 mW semi-conductor laser device delivering at 830 nm in continuous wave, 20.1 J/cm(2)/point, and three shots were given per session (1 treatment) with twice a week for 4 weeks. 1. A visual analogue scale (VAS) was used to determine the effects of LLLT for chronic pain and after the end of the treatment regimen a significant improvement was observed (pcervical spine range of motion were observed. 3. Discussions with the patients revealed that in order to receive continued benefits from treatment, it was important for them to be taught how to avoid postures that would cause them neck pain in everyday life. The present study demonstrates that LLLT was an effective form of treatment for neck and back pain caused by cervical disk hernia, reinforced by postural training.

  4. Effect of the upper-level decay on the resonantly enhanced four-wave mixing in a modified double-Λ system

    International Nuclear Information System (INIS)

    Kien, Fam Le; Hakuta, K.

    2004-01-01

    We study the continuous resonant four-wave mixing in a medium of atoms with a modified double-Λ level configuration. Under the far-off-resonance condition for a pair of levels, we reduce the five-level scheme to an effective three-level scheme, with a two-photon coupling between the two lower levels. We derive the exact steady-state solution to the density-matrix equations for the reduced scheme and obtain the wave-mixing equations for the fields in the continuous-wave regime. We show that the upper-level decay may substantially affect the resonantly enhanced wave-mixing process. We demonstrate that this decay shortens the conversion cycle rather than prolongs it

  5. Direct measurement of kilo-tesla level magnetic field generated with laser-driven capacitor-coil target by proton deflectometry

    Science.gov (United States)

    Law, K. F. F.; Bailly-Grandvaux, M.; Morace, A.; Sakata, S.; Matsuo, K.; Kojima, S.; Lee, S.; Vaisseau, X.; Arikawa, Y.; Yogo, A.; Kondo, K.; Zhang, Z.; Bellei, C.; Santos, J. J.; Fujioka, S.; Azechi, H.

    2016-02-01

    A kilo-tesla level, quasi-static magnetic field (B-field), which is generated with an intense laser-driven capacitor-coil target, was measured by proton deflectometry with a proper plasma shielding. Proton deflectometry is a direct and reliable method to diagnose strong, mm3-scale laser-produced B-field; however, this was not successful in the previous experiment. A target-normal-sheath-accelerated proton beam is deflected by Lorentz force in the laser-produced magnetic field with the resulting deflection pattern recorded on a radiochromic film stack. A 610 ± 30 T of B-field amplitude was inferred by comparing the experimental proton pattern with Monte-Carlo calculations. The amplitude and temporal evolutions of the laser-generated B-field were also measured by a differential magnetic probe, independently confirming the proton deflectometry measurement results.

  6. Upper atmosphere research: Reaction rate and optical measurements

    Science.gov (United States)

    Stief, L. J.; Allen, J. E., Jr.; Nava, D. F.; Payne, W. A., Jr.

    1990-01-01

    The objective is to provide photochemical, kinetic, and spectroscopic information necessary for photochemical models of the Earth's upper atmosphere and to examine reactions or reactants not presently in the models to either confirm the correctness of their exclusion or provide evidence to justify future inclusion in the models. New initiatives are being taken in technique development (many of them laser based) and in the application of established techniques to address gaps in the photochemical/kinetic data base, as well as to provide increasingly reliable information.

  7. Effects of increased low-level diode laser irradiation time on extraction socket healing in rats.

    Science.gov (United States)

    Park, Joon Bong; Ahn, Su-Jin; Kang, Yoon-Goo; Kim, Eun-Cheol; Heo, Jung Sun; Kang, Kyung Lhi

    2015-02-01

    In our previous studies, we confirmed that low-level laser therapy (LLLT) with a 980-nm gallium-aluminum-arsenide diode laser was beneficial for the healing of the alveolar bone in rats with systemic disease. However, many factors can affect the biostimulatory effects of LLLT. Thus, we attempted to investigate the effects of irradiation time on the healing of extraction sockets by evaluating the expressions of genes and proteins related to bone healing. The left and right first maxillary molars of 24 rats were extracted. Rats were randomly divided into four groups in which extraction sockets were irradiated for 0, 1, 2, or 5 min each day for 3 or 7 days. Specimens containing the sockets were examined using quantitative real-time reverse transcription polymerase chain reaction and western blotting. LLLT increased the expressions of all tested genes, Runx2, collagen type 1, osteocalcin, platelet-derived growth factor-B, and vascular endothelial growth factor, in a time-dependent manner. The highest levels of gene expressions were in the 5-min group after 7 days. Five minutes of irradiation caused prominent increases of the expression of all tested proteins after both 3 and 7 days. The expression level of each protein in group 4 was higher by almost twofold compared with group 1 after 7 days. Laser irradiation for 5 min caused the highest expressions of genes and proteins related to bone healing. In conclusion, LLLT had positive effects on the early stages of bone healing of extraction sockets in rats, which were irradiation time-dependent.

  8. EFSA Panel on Dietetic Products, Nutrition, and Allergies (NDA); Scientific Opinion on the Tolerable Upper Intake Level of calcium

    DEFF Research Database (Denmark)

    Tetens, Inge

    Following a request from the European Commission, the Panel on Dietetic Products, Nutrition and Allergies was asked to re-evaluate the safety in use of calcium. The Panel was requested to consider if the Tolerable Upper Intake Level (UL) for calcium established by the SCF in 2003 (2,500 mg...

  9. Approach and potentiality of low level laser therapy in veterinary medicine

    Science.gov (United States)

    Paterniani, Valentina; Grolli, Stefano

    2018-04-01

    The Low Level Laser Therapy (LLLT) is an innovative and increasing therapeutic technique in Veterinary Medicine. As in Human Medicine, the low power red/near-infrared laser light could be used to reduce inflammatory conditions, induce analgesia and promote damaged tissues repair, both in conventional animals like horses, dogs and cats and in unconventional ones, including reptiles, birds and exotic mammals. Since A.Eistein (1917) and E.Mester (1968) built its physical and biochemical fundamentals, a growing number of researches, over the years, have expanded the knowledge of the molecular process considered today at the basis of the macroscopic therapeutic effects. Producing a photochemical tissue interaction, laser light is absorbed by the mitochondrial respiratory chain stimulating the generation of ATP, ROS and NO; this determines a modulation in gene expression of proteins playing key roles in cellular processes as tissue repair, inflammatory response and pain control. Different animal pathological conditions could significantly benefit from this therapy, such as acute/chronic muscle-skeletal disorders, dental afflictions, dermatitis, otitis, stomatitis and different kind of skin lesions, as traumatic or post-operative ones. Furthermore, other significant applications are developing scientifically: the treatment of internal organ diseases, the regenerative effects on nervous tissue and the possibility of a beneficial cell-specific cytotoxicity, relevant for oncological cases, are some of these. A high-quality research is therefore crucial for this quickly expanding field of Veterinary Medicine, in order to find the most effective protocols and the ideal doses for each pathological conditions, aiming to always ensure the best and up-todate animal care.

  10. Laser propulsion for orbit transfer - Laser technology issues

    Science.gov (United States)

    Horvath, J. C.; Frisbee, R. H.

    1985-01-01

    Using reasonable near-term mission traffic models (1991-2000 being the assumed operational time of the system) and the most current unclassified laser and laser thruster information available, it was found that space-based laser propulsion orbit transfer vehicles (OTVs) can outperform the aerobraked chemical OTV over a 10-year life-cycle. The conservative traffic models used resulted in an optimum laser power of about 1 MW per laser. This is significantly lower than the power levels considered in other studies. Trip time was taken into account only to the extent that the system was sized to accomplish the mission schedule.

  11. Hyperfine structure of the odd parity level system in the terbium atom

    International Nuclear Information System (INIS)

    Stefanska, D; Furmann, B

    2017-01-01

    Within this work new experimental results concerning the hyperfine structure ( hfs ) in the terbium atom are presented, concerning the odd parity levels system, hitherto only scarcely investigated (apart from the ground term). hfs constants A and B for 113 levels were determined for the first time, and for another 16 levels, which already occurred in our earlier works, supplementary results were obtained; additionally, our earlier results for 93 levels were compiled. The hfs of the odd parity levels was investigated using the method of laser induced fluorescence in a hollow cathode discharge. The hfs of 165 spectral lines, where the levels in question were involved as the upper levels, was recorded. Literature values of hfs constants of the even-parity lower levels (including our own earlier results) greatly facilitated the present data evaluation. (paper)

  12. Aferição dos equipamentos de laser de baixa intensidade Calibration of low-level laser therapy equipment

    Directory of Open Access Journals (Sweden)

    Thiago Y. Fukuda

    2010-08-01

    Full Text Available CONTEXTUALIZAÇÃO: A laserterapia de baixa intensidade (LBI vem sendo cada vez mais utilizada, porém ainda não há consenso na literatura quanto ao tempo em que os equipamentos devem ser submetidos à aferição ou calibragem. OBJETIVO: Analisar a potência média real (PmR dos equipamentos de LBI na região da Grande São Paulo. MÉTODOS: Para análise dos equipamentos, utilizou-se um potenciômetro (Lasercheck, próprio para aferição de equipamentos contínuos, o qual foi programado com dados referentes ao comprimento de onda do laser a ser avaliado, obtendo-se assim a PmR emitida. Os equipamentos foram analisados de duas formas: uma, com o LBI desaquecido, e outra, após 10 minutos de uso (aquecido, sendo que três análises foram feitas para cada condição. A caneta emissora foi acoplada ao potenciômetro, o qual fornecia a PmR emitida pelo LBI. Todos os dados e informações referentes à aplicação do laser foram coletados por um questionário respondido pelos responsáveis. RESULTADOS: Os 60 equipamentos avaliados mostraram déficit na PmR com os equipamentos desaquecidos e aquecidos. A análise estatística (ANOVA mostrou diminuição significativa (PBACKGROUND: Despite the increase in the use of low-level laser therapy (LLLT, there is still a lack of consensus in the literature regarding how often the equipment must be calibrated. OBJECTIVE: To evaluate the real average power of LLLT devices in the Greater São Paulo area. METHODS: For the evaluation, a LaserCheck power meter designed to calibrate continuous equipment was used. The power meter was programmed with data related to the laser's wavelength to gauge the real average power being emitted. The LLLT devices were evaluated in two ways: first with the device cooled down and then with the device warmed up for 10 minutes. For each condition, three tests were performed. The laser probe was aligned with the power meter, which provided the real average power being emitted by the

  13. Ascorbic acid levels in human tears after photorefractive keratectomy, transepithelial photorefractive keratectomy, and laser in situ keratomileusis.

    Science.gov (United States)

    Bilgihan, A; Bilgihan, K; Toklu, Y; Konuk, O; Yis, O; Hasanreisoğlu, B

    2001-04-01

    To investigate the level of ascorbic acid in human tear fluid after photorefractive keratectomy (PRK), transepithelial PRK, and laser in situ keratomileusis (LASIK). Departments of Ophthalmology and Biochemistry, School of Medicine, Gazi University, Ankara, Turkey. Twenty patients (7 women and 13 men) were included in this study. Traditional PRK with epithelial scraping by a blunt spatula followed by surface ablation (7 eyes), transepithelial PRK (7 eyes), or LASIK (6 eyes) was performed. Tears were collected preoperatively and 1 and 5 days postoperatively. Ascorbic acid levels were measured using 2-4 dinitrophenylhydrazine. Ascorbic acid levels in the tear fluid were decreased significantly 1 day after PRK, transepithelial PRK, and LASIK (P <.05). On the fifth day, the ascorbic acid levels were significantly lower than preoperatively in all groups. After PRK, transepithelial PRK, and LASIK, the ascorbic acid levels of the tear fluid decreased significantly. Because ascorbic acid is the major scavenger of superoxide radicals in tears, topical ascorbic acid therapy may help eliminate the harmful effect of free radicals from excimer laser surgery.

  14. "Notice the Similarities between the Two Sets …": Imperative Usage in a Corpus of Upper-Level Student Papers

    Science.gov (United States)

    Neiderhiser, Justine A.; Kelley, Patrick; Kennedy, Kohlee M.; Swales, John M.; Vergaro, Carla

    2016-01-01

    The sparse literature on the use of imperatives in research papers suggests that they are relatively common in a small number of disciplines, but rare, if used at all, in others. The present study addresses the use of imperatives in a corpus of upper-level A-graded student papers from 16 disciplines. A total of 822 papers collected within the past…

  15. A new instrument of VUV laser desorption/ionization mass spectrometry imaging with micrometer spatial resolution and low level of molecular fragmentation.

    Science.gov (United States)

    Wang, Jia; Liu, Feng; Mo, Yuxiang; Wang, Zhaoying; Zhang, Sichun; Zhang, Xinrong

    2017-11-01

    Mass spectrometry imaging (MSI) has important applications in material research, biology, and medicine. The MSI method based on UV laser desorption/ionization (UVLDI) can obtain images of intact samples, but has a high level of molecular fragmentation. In this work, we report a new MSI instrument that uses a VUV laser (125.3 nm) as a desorption/ionization source to exploit its advantages of high single photon energy and small focus size. The new instrument was tested by the mass spectra of Nile red and FGB (Fibrinogen beta chain) samples and mass spectrometric images of a fly brain section. For the tested samples, the VUVDI method offers lower levels of molecular fragmentations and higher sensitivities than those of the UVLDI method and second ion mass spectrometry imaging method using a Bi 3 + beam. The ablation crater produced by the focused VUV laser on a quartz plate has an area of 10 μm 2 . The VUV laser is prepared based on the four-wave mixing method using three collimated laser beams and a heated Hg cell.

  16. A new instrument of VUV laser desorption/ionization mass spectrometry imaging with micrometer spatial resolution and low level of molecular fragmentation

    Science.gov (United States)

    Wang, Jia; Liu, Feng; Mo, Yuxiang; Wang, Zhaoying; Zhang, Sichun; Zhang, Xinrong

    2017-11-01

    Mass spectrometry imaging (MSI) has important applications in material research, biology, and medicine. The MSI method based on UV laser desorption/ionization (UVLDI) can obtain images of intact samples, but has a high level of molecular fragmentation. In this work, we report a new MSI instrument that uses a VUV laser (125.3 nm) as a desorption/ionization source to exploit its advantages of high single photon energy and small focus size. The new instrument was tested by the mass spectra of Nile red and FGB (Fibrinogen beta chain) samples and mass spectrometric images of a fly brain section. For the tested samples, the VUVDI method offers lower levels of molecular fragmentations and higher sensitivities than those of the UVLDI method and second ion mass spectrometry imaging method using a Bi3+ beam. The ablation crater produced by the focused VUV laser on a quartz plate has an area of 10 μm2. The VUV laser is prepared based on the four-wave mixing method using three collimated laser beams and a heated Hg cell.

  17. High-voltage measurements on the 5 ppm relative uncertainty level with collinear laser spectroscopy

    Science.gov (United States)

    Krämer, J.; König, K.; Geppert, Ch; Imgram, P.; Maaß, B.; Meisner, J.; Otten, E. W.; Passon, S.; Ratajczyk, T.; Ullmann, J.; Nörtershäuser, W.

    2018-04-01

    We present the results of high-voltage collinear laser spectroscopy measurements on the 5 ppm relative uncertainty level using a pump and probe scheme at the 4s ^2S1/2 → 4p ^2P3/2 transition of {\\hspace{0pt}}40Ca+ involving the 3d ^2D5/2 metastable state. With two-stage laser interaction and a reference measurement we can eliminate systematic effects such as differences in the contact potentials due to different electrode materials and thermoelectric voltages, and the unknown starting potential of the ions in the ion source. Voltage measurements were performed between  -5 kV and  -19 kV and parallel measurements with stable high-voltage dividers calibrated to 5 ppm relative uncertainty were used as a reference. Our measurements are compatible with the uncertainty limits of the high-voltage dividers and demonstrate an unprecedented (factor of 20) increase in the precision of direct laser-based high-voltage measurements.

  18. Vib--rotational energy distributions and relaxation processes in pulsed HF chemical lasers

    International Nuclear Information System (INIS)

    Ben-Shaul, A.; Kompa, K.L.; Schmailzl, U.

    1976-01-01

    The rate equations governing the temporal evolution of photon densities and level populations in pulsed F+H 2 →HF+H chemical lasers are solved for different initial conditions. The rate equations are solved simultaneously for all relevant vibrational--rotational levels and vibrational--rotational P-branch transitions. Rotational equilibrium is not assumed. Approximate expressions for the detailed state-to-state rate constants corresponding to the various energy transfer processes (V--V, V--R,T, R--R,T) coupling the vib--rotational levels are formulated on the basis of experimental data, approximate theories, and qualitative considerations. The main findings are as follows: At low pressures, R--T transfer cannot compete with the stimulated emission, and the laser output largely reflects the nonequilibrium energy distribution in the pumping reaction. The various transitions reach threshold and decay almost independently and simultaneous lasing on several lines takes place. When a buffer gas is added in excess to the reacting mixture, the enhanced rotational relaxation leads to nearly single-line operation and to the J shift in lasing. Laser efficiency is higher at high inert gas pressures owing to a better extraction of the internal energy from partially inverted populations. V--V exchange enhances lasing from upper vibrational levels but reduces the total pulse intensity. V--R,T processes reduce the efficiency but do not substantially modify the spectral output distribution. The photon yield ranges between 0.4 and 1.4 photons/HF molecule depending on the initial conditions. Comparison with experimental data, when available, is fair

  19. Low levels of 25-hydroxyvitamin D are associated with the occurrence of concomitant upper limb fractures in older women who sustain a fall-related fracture of the hip.

    Science.gov (United States)

    Di Monaco, Marco; Vallero, Fulvia; Castiglioni, Carlotta; Di Monaco, Roberto; Tappero, Rosa

    2011-01-01

    To investigate the association between serum levels of 25-hydroxyvitamin D and the occurrence of simultaneous fractures of the upper limb in older women who sustain a fall-related fracture of the hip. Cross-sectional study. We investigated 472 of 480 white women consecutively admitted to a rehabilitation hospital because of a fall-related hip fracture. Twenty-seven (5.7%) of the 472 women sustained a concomitant upper-limb fracture of either distal radius (20 women) or proximal humerus (seven women). We assessed serum levels of 25-hydroxyvitamin D 14.2 ± 4.1 (mean ± SD) days after surgical repair of the hip fracture in the 472 women by an immunoenzymatic assay. Twenty-five-hydroxyvitamin D levels were significantly lower in the 27 women with concomitant fractures of both hip and upper limb than in the remaining 445 hip-fracture women: mean ± SD values were 6.5 ± 5.0 ng/ml and 11.7 ± 10.4 ng/ml respectively in the two groups (mean difference between groups 5.2 ng/ml: 95% CI 1.2-9.2; p=0.011). Low levels of 25-hydroxyvitamin D were significantly associated with concomitant fractures of the upper limb (p=0.017), after adjustment for eight potential confounders including age, height, weight, hip-fracture type, cognitive impairment, neurologic impairment, previous hip fracture, and previous upper-limb fracture. Low levels of 25-hydroxyvitamin D were significantly associated with concomitant upper-limb fractures in our sample of older women with a fall-related fracture of the hip. Preventing vitamin D deficiency may lower the incidence of simultaneous fractures due to a singe fall in elderly women. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  20. Superluminous Devices Versus Low-Level Laser for Temporomandibular Disorders

    Directory of Open Access Journals (Sweden)

    Sveshtarov Vasil

    2018-03-01

    Full Text Available The aim of this study is to compare the pain intensity reduction between the mean radiation doses per session of gallium-aluminum-arsenide (GaAIAs laser with superluminous diodes (SLD in four of the most common pain-related chronic temporomandibular disorders (TMD - local myalgia, myofascial pain, myofascial pain with a referral, and arthralgia. This study was implemented on 124 patients with pain-related temporomandibular disorders according to the DC/TMD criteria. We applied trigger point oriented near-infrared laser (785 nm, 100 s, 8 J/cm2 and SLD cluster sessions (the cluster is composed of 49 SLDs with a combination of visible red (633 nm and infrared (880 nm diodes, 200 mW, 300 s, 8 J/cm2 for the temporomandibular joints and the affected muscles. Patients were evaluated at the start of the treatment, and after the 6th session of combined phototherapy. The pain intensity scores were measured according to the Visual Analogue Scale (VAS. Our results show that the most statistically manifested pain reduction is found for the SLD dose, р = 0,000118, followed by the overall dose (laser plus SLD; р = 0,001031, and the laser dose; р = 0,030942 (ANOVA dispersion analyses. Consequently, it can be concluded that myalgia is better treated through lower doses of red light compared to infrared laser doses because SLDs combine the prooxidative effect of photons with 633 nm wavelength, a large area of exposure, sufficient tissue penetration, and some positive warming thermal impact of the SLD clusters.

  1. Upper Limb Asymmetry in the Sense of Effort Is Dependent on Force Level

    Directory of Open Access Journals (Sweden)

    Diane E. Adamo

    2017-04-01

    Full Text Available Previous studies have shown that asymmetries in upper limb sensorimotor function are dependent on the source of sensory and motor information, hand preference and differences in hand strength. Further, the utilization of sensory and motor information and the mode of control of force may differ between the right hand/left hemisphere and left hand/right hemisphere systems. To more clearly understand the unique contribution of hand strength and intrinsic differences to the control of grasp force, we investigated hand/hemisphere differences when the source of force information was encoded at two different force levels corresponding to a 20 and 70% maximum voluntary contraction or the right and left hand of each participant. Eleven, adult males who demonstrated a stronger right than left maximum grasp force were requested to match a right or left hand 20 or 70% maximal voluntary contraction reference force with the opposite hand. During the matching task, visual feedback corresponding to the production of the reference force was available and then removed when the contralateral hand performed the match. The matching relative force error was significantly different between hands for the 70% MVC reference force but not for the 20% MVC reference force. Directional asymmetries, quantified as the matching force constant error, showed right hand overshoots and left undershoots were force dependent and primarily due to greater undershoots when matching with the left hand the right hand reference force. Findings further suggest that the interaction between internal sources of information, such as efferent copy and proprioception, as well as hand strength differences appear to be hand/hemisphere system dependent. Investigations of force matching tasks under conditions whereby force level is varied and visual feedback of the reference force is available provides critical baseline information for building effective interventions for asymmetric (stroke

  2. Low-level laser therapy for the treatment of androgenic alopecia: a review.

    Science.gov (United States)

    Darwin, Evan; Heyes, Alexandra; Hirt, Penelope A; Wikramanayake, Tongyu Cao; Jimenez, Joaquin J

    2018-02-01

    There are many new low-level laser technologies that have been released commercially that claim to support hair regrowth. In this paper, we will examine the clinical trials to determine whether the body of evidence supports the use of low-level laser therapy (LLLT) to treat androgenic alopecia (AGA). A literature search was conducted through Pubmed, Embase, and Clinicaltrials.gov for clinical trials using LLLT to treat AGA. Thirteen clinical trials were assessed. Review articles were not included. Ten of 11 trials demonstrated significant improvement of androgenic alopecia in comparison to baseline or controls when treated with LLLT. In the remaining study, improvement in hair counts and hair diameter was recorded, but did not reach statistical significance. Two trials did not include statistical analysis, but showed marked improvement by hair count or by photographic evidence. Two trials showed efficacy for LLLT in combination with topical minoxidil. One trial showed efficacy when accompanying finasteride treatment. LLLT appears to be a safe, alternative treatment for patients with androgenic alopecia. Clinical trials have indicated efficacy for androgenic alopecia in both men and women. It may be used independently or as an adjuvant of minoxidil or finasteride. More research needs to be undertaken to determine the optimal power and wavelength to use in LLLT as well as LLLT's mechanism of action.

  3. Reconstructing Northern Hemisphere upper-level fields during World War II

    Energy Technology Data Exchange (ETDEWEB)

    Broennimann, S. [Lunar and Planetary Laboratory, University of Arizona, PO Box 210092, Tucson, AZ 85721-0092 (United States); Luterbacher, J. [Institute of Geography, University of Bern, Bern (Switzerland); NCCR Climate, University of Bern, Bern (Switzerland)

    2004-05-01

    Monthly mean fields of temperature and geopotential height (GPH) from 700 to 100 hPa were statistically reconstructed for the extratropical Northern Hemisphere for the World War II period. The reconstruction was based on several hundred predictor variables, comprising temperature series from meteorological stations and gridded sea level pressure data (1939-1947) as well as a large amount of historical upper-air data (1939-1944). Statistical models were fitted in a calibration period (1948-1994) using the NCEP/NCAR Reanalysis data set as predictand. The procedure consists of a weighting scheme, principal component analyses on both the predictor variables and the predictand fields and multiple regression models relating the two sets of principal component time series to each other. According to validation experiments, the reconstruction skill in the 1939-1944 period is excellent for GPH at all levels and good for temperature up to 500 hPa, but somewhat worse for 300 hPa temperature and clearly worse for 100 hPa temperature. Regionally, high predictive skill is found over the midlatitudes of Europe and North America, but a lower quality over Asia, the subtropics, and the Arctic. Moreover, the quality is considerably better in winter than in summer. In the 1945-1947 period, reconstructions are useful up to 300 hPa for GPH and, in winter, up to 500 hPa for temperature. The reconstructed fields are presented for selected months and analysed from a dynamical perspective. It is demonstrated that the reconstructions provide a useful tool for the analysis of large-scale circulation features as well as stratosphere-troposphere coupling in the late 1930s and early 1940s. (orig.)

  4. Recent laser experiments on the Aurora KrF/ICF laser system

    International Nuclear Information System (INIS)

    Turner, T.P.; Jones, J.E.; Czuchlewski, S.J.; Watt, R.G.; Thomas, S.J.; Kang, M.; Tallman, C.R.; Mack, J.M.; Figueira, J.F.

    1990-01-01

    The Aurora KrF/ICF Laser Facility at Los Alamos is operational at the kilojoule-level for both laser and target experiments. We report on recent laser experiments on the system and resulting system improvements. 3 refs., 4 figs

  5. Effect of preoperative ibuprofen in controlling postendodontic pain with and without low-level laser therapy in single visit endodontics: A randomized clinical study

    Directory of Open Access Journals (Sweden)

    Shahnaz Nabi

    2018-01-01

    Full Text Available Aim: The aim of this study is to evaluate the effect of low-level laser irradiation and ibuprofen in reducing the onset and severity of postoperative pain following single visit endodontics. Materials and Methods: One hundred and twenty patients were recruited for this study. Group A (n = 30 patients were administered 400 mg of ibuprofen orally 1 h before the institution of an endodontic procedure. Group B (n = 30 patients were given irradiation of a low-level laser at 50 Hz for 3 min after the standard endodontic procedure at the periapical region on both buccal and lingual aspect. Group C (n = 30 patients were given preoperative ibuprofen followed with a low-level laser at 50 Hz for 3 min after endodontic treatment. Group D (n = 30 patients were administered no preoperative ibuprofen nor low-level laser irradiation after the endodontic procedure. The patient immediately recorded his/her pain perception on the Heft Parker pain survey after completion of the appointment and at 4, 8, 12, 24, and 48 h postoperatively. Inter group analysis was carried out using the analysis of variances with “least significant difference” post hoc test. For intra group analysis, Student's t-test was used. Chi-square test was applied for nonparametric data. Results: Pain was significantly reduced in all the treatment groups postoperatively. Ibuprofen showed significant pain reduction at 4 h and 8 h period. The combination of low-level laser and ibuprofen showed the best results in terms of postoperative pain reduction. Conclusion: This study proved that low-level laser therapy can be an effective alternative for conventional use of nonsteroidal anti-inflammatory drugs in controlling postendodontic pain thereby eliminating the adverse effects of such drugs on the patients.

  6. Kilowatt average power 100 J-level diode pumped solid state laser

    Czech Academy of Sciences Publication Activity Database

    Mason, P.; Divoký, Martin; Ertel, K.; Pilař, Jan; Butcher, T.; Hanuš, Martin; Banerjee, S.; Phillips, J.; Smith, J.; De Vido, M.; Lucianetti, Antonio; Hernandez-Gomez, C.; Edwards, C.; Mocek, Tomáš; Collier, J.

    2017-01-01

    Roč. 4, č. 4 (2017), s. 438-439 ISSN 2334-2536 R&D Projects: GA MŠk LO1602; GA MŠk LM2015086 Institutional support: RVO:68378271 Keywords : diode-pumped * solid state * laser Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 7.727, year: 2016

  7. Low-level laser therapy: Case-control study in dogs with sterile pyogranulomatous pododermatitis

    Directory of Open Access Journals (Sweden)

    Roberta Perego

    2016-08-01

    Full Text Available Aim: Low-level laser therapy (LLLT is a therapeutic photobiostimulation with properties in reducing swelling, inflammation, and promoting tissue healing. The objective of this pilot study was to evaluate LLLT in sterile pyogranulomatous pododermatitis in five dogs. Materials and Methods: In each dog, one lesion was designated as the control (treated with a 0.0584% hydrocortisone aceponate spray, and one or more other lesions were treated with a gallium aluminum arsenide-laser, daily for 5 days. Lesions were scored before treatment (D0, at the end (D4, 16 days after the last laser treatment (D20, and after 2 months (D65. Results: Comparing the treated lesion group with the control lesion group, the clinical score was similar at D0, whereas there was a statistically significant difference at D4 and D20; in the treated group over time, there was a statistically significant improvement between D0, D4, and D20. Lesion recurrence was absent in more than 50% of the treated lesions at D65. No adverse reactions were reported. Conclusion: Given the positive results of this first clinical study, it would be interesting to extend the study to confirm the validity of this type of therapy in sterile pyogranulomatous pododermatitis in the dog.

  8. Theoretical investigation of injection-locked high modulation bandwidth quantum cascade lasers.

    Science.gov (United States)

    Meng, Bo; Wang, Qi Jie

    2012-01-16

    In this study, we report for the first time to our knowledge theoretical investigation of modulation responses of injection-locked mid-infrared quantum cascade lasers (QCLs) at wavelengths of 4.6 μm and 9 μm, respectively. It is shown through a three-level rate equations model that the direct intensity modulation of QCLs gives the maximum modulation bandwidths of ~7 GHz at 4.6 μm and ~20 GHz at 9 μm. By applying the injection locking scheme, we find that the modulation bandwidths of up to ~30 GHz and ~70 GHz can be achieved for QCLs at 4.6 μm and 9 μm, respectively, with an injection ratio of 5 dB. The result also shows that an ultrawide modulation bandwidth of more than 200 GHz is possible with a 10 dB injection ratio for QCLs at 9 μm. An important characteristic of injection-locked QCLs is the nonexistence of unstable locking region in the locking map, in contrast to their diode laser counterparts. We attribute this to the ultra-short upper laser state lifetimes of QCLs.

  9. A score card for upper GI endoscopy: Evaluation of interobserver variability in examiners with various levels of experience.

    Science.gov (United States)

    Neumann, M; Friedl, S; Meining, A; Egger, K; Heldwein, W; Rey, J F; Hochberger, J; Classen, M; Hohenberger, W; Rösch, T

    2002-10-01

    In most European countries, training in GI endoscopy has largely been based on hands-on acquisition of experience in patients rather than on a structured training programme. With the development of training models systematic hands-on training in a variety of diagnostic and therapeutic endoscopy techniques was achieved. Little, however, is known about methods of objectively assessing trainees' performance. We therefore developed an assessment 'score card' for upper GI endoscopy and tested it in endoscopists with various levels of experience. The aim of the study was therefore to assess interobserver variations in the evaluation of trainees. On the basis of textbook and expert opinions a consensus group of eight experienced endoscopists developed a score card for diagnostic upper GI endoscopy with biopsy. The score card includes an assessment of the single steps of the procedure as well as of the times needed to complete each step. This score card was then evaluated in a further conference including ten experts who blindly assessed videotapes of 15 endoscopists performing upper GI endoscopy in a training bio-simulation model (the 'Erlangen Endo-Trainer'). On the basis of their previous experience (i. e. the number of endoscopies performed) these 15 endoscopists were classified into four groups: very experienced, experienced, having some experience and inexperienced. Interobserver variability (IOV) was tested for the various score card parameters (Kendall's rank-correlation coefficient 0.0-0.5 poor, 0.5-1.0 good agreement). In addition, the correlation between the score card assessment and the examiners' experience levels was analysed. Despite poor IOV results for all the parameters tested (Kendall coefficient account (correlation coefficient 0.59-0.89, p < 0.05). The score card parameters were suitable for differentiating between the four groups of examiners with different levels of endoscopic experience. As expected with scores involving subjective assessment of

  10. Theoretical predictions for the polarization of the J = 0 - 1 neonlike germanium X-ray laser line in the presence of a directed beam of hot electrons

    International Nuclear Information System (INIS)

    Inal, M.K.; Dubau, J.; Cornille, M.

    1998-01-01

    The polarization of the neonlike germanium J = 0 - 1 laser line, which would arise from the existence of a directed beam of hot electrons in the amplifying plasma, is theoretically investigated. The relative populations of the magnetic sublevels in the lower J = 1 laser level have been determined by allowing for the processes of direct excitation from the 2p 6 ground level and collisional de-excitation from the upper J = 0 laser level. Elastic collisions leading to transitions between the M J = 0 and M J =1 sublevels within the lower level of the lasing line have also been taken into account. The required elastic and inelastic collision strengths for transitions between magnetic sublevels have been computed in a semi-relativistic distorted-wave approximation, for incident electron energies up to 15 keV. Our calculations predict a rather low degree of polarization for the J = 0 - 1 line, although the elastic collisions are found to play a negligibly small role in the redistribution of magnetic sublevel populations. (author)

  11. The effects of transcutaneous low-level laser therapy on the skin healing process: an experimental model.

    Science.gov (United States)

    Ramos, Felipe Scholz; Maifrino, Laura Beatriz Mesiano; Alves, Sarah; da Costa Aguiar Alves, Beatriz; Perez, Matheus Moreira; Feder, David; Azzalis, Ligia Ajaime; Junqueira, Virginia Berlanga Campos; Fonseca, Fernando Luiz Affonso

    2018-01-06

    We aim to evaluate the action of transcutaneous laser in the initial wound healing process. The use of low-level laser therapy (LLLT) has proven to be effective on inflammatory modulation and wound healing. The trial was performed on five groups of rats, through a dorsal incision. All groups received treatment on auricular artery. Groups 1 and 3 were treated with transcutaneous LLLT over a period of 15 min. Groups 2 and 4 received one and two inactive laser applications (placebo), respectively. Group 5 was the control one. Blood samples were collected 2 h after the last application of LLLT so that cytokine levels could be measured by ELISA. Tissue fragments were harvested for morphometric, histomorphometric, and RT-qPCR analyses. The morphometric analysis revealed a greater decrease in the wounded area in G1 when compared with G2, whereas in G3, the improvement in the area was greater when compared with G4. Finally, the histomorphometric analysis showed that G1 was the group closer to G5 in terms of collagen fiber count. G2 and G4 had higher amounts of collagen fibers than G5 while G3 had a lower quantity. The use of the transcutaneous LLLT in the current study influenced the wound healing process.

  12. Effects of low-level laser therapy on orthodontic tooth movement and root resorption after artificial socket preservation.

    Science.gov (United States)

    Seifi, Massoud; Atri, Faezeh; Yazdani, Mohammad Masoud

    2014-01-01

    Low- level laser therapy has been used to stimulate the orthodontic tooth movements (OTM) previously. Furthermore, in the orthodontic treatments accompanying tooth extractions, the adjacent teeth move towards the extraction sites and close the space in some cases. Then, the adjacent tooth movements must be prevented in the treatments requiring space. Laser stimulates and at some doses decelerates tooth movement; it also improves healing process and enhances osteogenesis. Hence, it can prevent movement by osteogenesis adjacent to the tooth. The present study investigated the effects of low-level laser therapy on the OTM and root resorption following artificial socket preservation. In this experimental animal trial, 16 male albino rabbits were selected with similar characteristics and randomly divided in two groups. Under general anesthesia, an artificial socket, 8 mm in height, was created in the mesial aspect of the first premolars of the rabbits and filled with demineralized freeze dried bone allograft (DFDBA). The first premolars were connected to the incisors using nickel titanium coil springs. In experimental group, gallium-aluminum-arsenide (GaAlAs) laser was irritated mesial to first premolar where artificial socket was created continuously (808 nm). The cycle was 10 days irritation, 14 days rest, 10 days irritation, 14 days rest (Biostimulation mode). Control group was not laser irradiated. All animals were sacrificed after 48 days and the distance between the distal aspect of the first premolars, and the mesial surface of the second premolars was measured with leaf gauge. The specimens underwent histological assessments. Integrity of root and its resorption was observed under microscope calibration. The size of resorption lacunae was calculated in mm(2). Normality of data was proved according to Kolmogorov-Smirnov analysis, and Student's t-test was done. P value less than 0.05 was considered as significant. The mean OTM were 5.68 ± 1.21 mm in the control

  13. Estimation of Soil Nitrate (NO3) Level Using Laser-Induced Breakdown Spectroscopy (LIBS)

    Science.gov (United States)

    Angkat, A. R.; Seminar, K. B.; Rahmat, M.; Sutandi, A.

    2018-05-01

    Laser-Induced Breakdown Spectroscopy (LIBS) is a method for measuring level of nitrogen (N) in the soil in the form of N-nitrate (NO3) rapidly without going through the process of sieving and drying. The sample soil in the form of pellets subjected to laser pulses using a wavelength of 532 nm, pulse duration 5.5 ns, repetition rate of 10 Hz, and Q-switch delay of 150 μs. Emissions are captured by the spectrometer with the wavelength range of 190-1130 nm. Spectrum characterization was processed through the second derivative in order to obtain a wavelength identity that could be rapidly used to estimate the nitrate content of the soil with a determination coefficient of (R2) 0.9254 and a coefficient of variation (CV) of 8.41%. The results of this study are very potential to be applied for rapid measurement of soil nitrate.

  14. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on the Tolerable Upper Intake Level of vitamin D

    DEFF Research Database (Denmark)

    Tetens, Inge

    Following a request from the European Commission, the Panel on Dietetic Products, Nutrition and Allergies was asked to re-evaluate the safety in use of vitamin D and to provide, if necessary, revised Tolerable Upper Intake Levels (ULs) of vitamin D for all relevant population groups. The ULs...

  15. Detection of carbon monoxide (CO) in sooting hydrocarbon flames using femtosecond two-photon laser-induced fluorescence (fs-TPLIF)

    Science.gov (United States)

    Wang, Yejun; Kulatilaka, Waruna D.

    2018-01-01

    Ultrashort-pulse, femtosecond (fs)-duration, two-photon laser-induced fluorescence (fs-TPLIF) measurements of carbon monoxide (CO) are reported in rich, sooting hydrocarbon flames. CO-TPLIF detection using conventional nanosecond or picosecond lasers are often plagued by photochemical interferences, specifically under fuel-rich flames conditions. In the current study, we investigate the commonly used CO two-photon excitation scheme of the B1Σ+ ← X1Σ+ electronic transition, using approximately 100-fs-duration excitation pulses. Fluorescence emission was observed in the Ångström band originating from directly populated B1Σ+ upper state, as well as, in the third positive band from collisionally populated b3Σ+ upper state. The current work was focused on the Ångström band emission. Interference from nascent C2 emissions originating from hot soot particles in the flame could be reduced to a negligible level using a narrower detection gate width. In contrast, avoiding interferences from laser-generated C2 Swan-band emissions required specific narrowband spectral filtering in sooting flame conditions. The observed less than quadratic laser pulse energy dependence of the TPLIF signal suggests the presence of strong three-photon ionization and stimulated emission processes. In a range of CH4/air and C2H4/air premixed flames investigated, the measured CO fluorescence signals agree well with the calculated equilibrium CO number densities. Reduced-interference CO-TPLIF imaging in premixed C2H4/O2/N2 jet flames is also reported.

  16. Urinary tract infection in childhood: lower or upper level? DMSA scintigraphic validation of a new clinical risk index

    International Nuclear Information System (INIS)

    Bayet-Papin, B.; Decomps-Hofmann, A.; Bovier-Lapierre, M.

    2001-01-01

    Urinary tract infection in children can be limited most of time at the lower level of the urinary tractus but an extension to the upper level of the tractus should not be neglected due to the asymptomatic nature of the disease. In our study, we suggest a new graph to predict the probability of acute pyelonephritis only if the bacteriological urinary analyse were obtained in good conditions and without any treatment. In the other cases, a DMSA scintigram should be proposed at the earlier phase of the diagnosis not to underestimate the risk of asymptomatic pyelonephritis. (authors)

  17. EFFICACY OF LOW LEVEL LASER THERAPY IN THE TREATMENT OF ALOPECIA AREATA

    OpenAIRE

    Nermeen Mohamed Abdelhalim. PhD PT

    2014-01-01

    Background: Alopecia areata is a chronic inflammatory disease which affects the hair follicles and sometimes the nails. Purpose: The purpose of this study was to evaluate the efficacy of low level laser therapy in the treatment of alopecia areata of the scalp. Method: Twenty three patients (14 male and 9 female) had 2 or more patches of the scalp, one patch was left for comparison as a control patches. The age ranged from 22 to 39 years with 30 ± 6.09 years mean. The study p...

  18. Can combined use of low-level lasers and hyaluronic acid injections prolong the longevity of degenerative knee joints?

    Science.gov (United States)

    Ip, David; Fu, Nga Yue

    2015-01-01

    This study evaluated whether half-yearly hyaluronic acid injection together with low-level laser therapy in addition to standard conventional physical therapy can successfully postpone the need for joint replacement surgery in elderly patients with bilateral symptomatic tricompartmental knee arthritis. In this prospective, double-blind, placebo-controlled study, 70 consecutive unselected elderly patients with bilateral tricompartmental knee arthritis were assigned at random to either one of two conservative treatment protocols to either one of the painful knees. Protocol A consisted of conventional physical therapy plus a sham light source plus saline injection, and protocol B consisted of protocol A with addition of half-yearly hyaluronic acid injection as well as low-level laser treatment instead of using saline and a sham light source. Treatment failure was defined as breakthrough pain necessitating joint replacement. Among the 140 painful knees treated with either protocol A or protocol B, only one of the 70 painful knees treated by protocol B required joint replacement, whereas 15 of the 70 painful knees treated by protocol A needed joint replacement surgery (Phyaluronic acid injections together with low-level laser therapy should be incorporated into the standard conservative treatment protocol for symptomatic knee arthritis, because it may prolong the longevity of the knee joint without the need for joint replacement.

  19. Low-level laser therapy activates NF-kB via generation of reactive oxygen species in mouse embryonic fibroblasts.

    Directory of Open Access Journals (Sweden)

    Aaron C-H Chen

    Full Text Available Despite over forty years of investigation on low-level light therapy (LLLT, the fundamental mechanisms underlying photobiomodulation at a cellular level remain unclear.In this study, we isolated murine embryonic fibroblasts (MEF from transgenic NF-kB luciferase reporter mice and studied their response to 810 nm laser radiation. Significant activation of NF-kB was observed at fluences higher than 0.003 J/cm(2 and was confirmed by Western blot analysis. NF-kB was activated earlier (1 hour by LLLT compared to conventional lipopolysaccharide treatment. We also observed that LLLT induced intracellular reactive oxygen species (ROS production similar to mitochondrial inhibitors, such as antimycin A, rotenone and paraquat. Furthermore, we observed similar NF-kB activation with these mitochondrial inhibitors. These results, together with inhibition of laser induced NF-kB activation by antioxidants, suggests that ROS play an important role in the laser induced NF-kB signaling pathways. However, LLLT, unlike mitochondrial inhibitors, induced increased cellular ATP levels, which indicates that LLLT also upregulates mitochondrial respiration.We conclude that LLLT not only enhances mitochondrial respiration, but also activates the redox-sensitive NFkB signaling via generation of ROS. Expression of anti-apoptosis and pro-survival genes responsive to NFkB could explain many clinical effects of LLLT.

  20. Watt-Level Continuous-Wave Emission from a Bi-Functional Quantum Cascade Laser/Detector

    Science.gov (United States)

    2017-04-18

    cally authorized by the U.S. Government may violate any copyrights that exist in this work. Watt-level continuous- wave emission from a bi- functional ... wave bi- functional devices, opens the perspective of on-chip dual comb spectroscopy. Also for discrete sens- ing setups, one can switch to lasers...seas.harvard.edu Abstract Bi- functional active regions, capable of light generation and detection at the same wavelength, allow a straightforward realization of

  1. Spatial variability of oceanic phycoerythrin spectral types derived from airborne laser-induced fluorescence emissions

    Science.gov (United States)

    Hoge, Frank E.; Wright, C. Wayne; Kana, Todd M.; Swift, Robert N.; Yungel, James K.

    1998-07-01

    We report spatial variability of oceanic phycoerythrin spectral types detected by means of a blue spectral shift in airborne laser-induced fluorescence emission. The blue shift of the phycoerythrobilin fluorescence is known from laboratory studies to be induced by phycourobilin chromophore substitution at phycoerythrobilin chromophore sites in some strains of phycoerythrin-containing marine cyanobacteria. The airborne 532-nm laser-induced phycoerythrin fluorescence of the upper oceanic volume showed distinct segregation of cyanobacterial chromophore types in a flight transect from coastal water to the Sargasso Sea in the western North Atlantic. High phycourobilin levels were restricted to the oceanic (oligotrophic) end of the flight transect, in agreement with historical ship findings. These remotely observed phycoerythrin spectral fluorescence shifts have the potential to permit rapid, wide-area studies of the spatial variability of spectrally distinct cyanobacteria, especially across interfacial regions of coastal and oceanic water masses. Airborne laser-induced phytoplankton spectral fluorescence observations also further the development of satellite algorithms for passive detection of phytoplankton pigments. Optical modifications to the NASA Airborne Oceanographic Lidar are briefly described that permitted observation of the fluorescence spectral shifts.

  2. Cryogenic Yb: YAG Thin-Disk Laser

    Science.gov (United States)

    2016-09-09

    as a 4- level laser. Its absorption and emission cross-sections increase, and its thermal conductivity improves. Yb:YAG thin disk laser performance...Air Force Base, NM USA 87117 4RINI Technologies, 582 South Econ Circle, Oviedo, FL USA 32765 Keywords: Laser materials; Lasers, ytterbium...temperatures, Yb:YAG behaves as a 4- level laser. Its absorption and emission cross-sections increase, and its thermal conductivity improves. Yb:YAG

  3. Comparison of positive-pressure, passive ultrasonic, and laser-activated irrigations on smear-layer removal from the root canal surface.

    Science.gov (United States)

    Sahar-Helft, Sharonit; Sarp, Ayşe Sena Kabaş; Stabholtz, Adam; Gutkin, Vitaly; Redenski, Idan; Steinberg, Doron

    2015-03-01

    The purpose of this study was to compare the efficacy of three irrigation techniques for smear-layer removal with 17% EDTA. Cleaning and shaping the root canal system during endodontic treatment produces a smear layer and hard tissue debris. Three irrigation techniques were tested for solution infiltration of this layer: positive-pressure irrigation, passive ultrasonic irrigation, and laser-activated irrigation. Sixty extracted teeth were divided into six equal groups; 17% EDTA was used for 60 sec irrigation of five of the groups. The groups were as follows: Group 1, treated only with ProTaper™ F3 Ni-Ti files; Group 2, positive-pressure irrigation, with a syringe; Group 3, passive ultrasonic irrigation, inserted 1 mm short of the working length; Group 4, passive ultrasonic irrigation, inserted in the upper coronal third of the root; Group 5, Er:YAG laser-activated irrigation, inserted 1 mm short of the working length; and Group 6, Er:YAG laser-activated irrigation, inserted in the upper coronal third of the root. Scanning electron microscopy showed that the smear layer is removed most efficiently using laser-activated irrigation at low energy with 17% EDTA, inserted either at the working length or only in the coronal upper third of the root. Amounts of Ca, P, and O were not significantly different on all treated dentin surfaces. Smear-layer removal was most effective when the root canals were irrigated using Er:YAG laser at low energy with 17% EDTA solution. Interestingly, removal of the smear layer along the entire canal was similar when the laser was inserted in the upper coronal third and at 1 mm short of the working length of the root canal. This effect was not observed with the ultrasonic and positive-pressure techniques.

  4. Gingiva laser welding: preliminary study on an ex vivo porcine model.

    Science.gov (United States)

    Rasca, Emilia; Nyssen-Behets, Catherine; Tielemans, Marc; Peremans, André; Hendaoui, Nordine; Heysselaer, Daniel; Romeo, Umberto; Nammour, Samir

    2014-08-01

    The use of lasers to fuse different tissues has been studied for 50 years. As none of these experiments concerned the oral soft tissues, our objective was to assess the feasibility of laser gingiva welding. Porcine full-thickness gingival flaps served to prepare calibrated samples in the middle of which a 2 cm long incision was closed, either by conventional suture or by laser tissue welding (LTW). To determine the irradiation conditions yielding the best tensile strength, 13 output power values, from 0.5 to 5 W, delivered either at 10 Hz or in continuous wave mode, were tested on six indocyanine green (ICG) concentrations, from 8% to 13% (588 samples). Then, some samples served to compare the tensile strength between the laser welded and the sutured gingiva; the other samples were histologically processed in order to evaluate the thermal damage extent. The temperature rise during the LTW was measured by thermocouples. Another group of 12 samples was used to measure the temperature elevation by thermal camera. In the laser welding groups, the best tensile strength (pwelded gingiva at 4.5 W, 10 Hz, and 9% ICG solution. The mean temperature was 74±5.4°C at the upper surface and 42±8.9°C at the lower surface. The damaged zone averaged 333 μm at the upper surface. The 808 nm diode laser associated with ICG can achieve oral mucosa LTW, which is conceivable as a promising technique of gingival repair.

  5. Comparative study between the effects of isolated manual therapy techniques and those associated with low level laser therapy on pain in patients with temporomandibular dysfunction

    Directory of Open Access Journals (Sweden)

    Juliana Cristina Frare

    2008-01-01

    Full Text Available Objective: This study sought to evaluate the pain condition in patients with temporomandibular dysfunction after applying manual therapy techniques and those associated with this low level laser therapy. Methods: The study involved 20 patients with temporomandibular dysfunction, divided randomly into two groups: G1 (n = 10, formed by 7 women and 3 men, average age 28.2 years (± 7, treated with manual therapy techniques and G2 (n = 10, formed by 8 women and 2 men, with average age 24.01 (± 6.04, treated with the combination of manual therapy techniques and low level laser therapy. The patients were treated three times a week for four consecutive weeks. The memorandum of manual therapy techniques based on Chaintow,Makofsky and Bienfaint was used. For low level laser therapy GaAs laser (904 nm, 6 J/cm2, 0.38 mW/cm2 was used, applied at 4pre-auricular points. To analyze the pain level, the visual analog pain scale was used. For data analysis the Student’s-t and Wilcoxon tests were used, both with significance level of 5% (p <0.05.Results: There was significant reduction (p <0.05 in the level of pain in both groups treated, but in G2 the significance was higher.Conclusion: Manual therapy techniques, either alone or associated with low level laser therapy showed satisfactory results for pain control in patients with temporomandibular dysfunction.

  6. Use of low-level laser therapy in treatment of the androgenic alopecia, the first systematic review.

    Science.gov (United States)

    Najem, Ibrahim; Chen, Hongxiang

    2017-12-11

    Alopecia is a common disease affecting more than half of the world total number of people. Alopecia exists in different types, but one of the most common of these types is the Androgenic Alopecia which has affected approximately 51% of the total number of males ranging between the age bracket of 40 years and 75 years. This type of alopecia is more common in females who are above the age of 65 years and above. Despite this widespread effect, much has not been done regarding identifying the possible drugs for treating this disease. At present, there exist only two possible medications that have been scientifically approved to cure this disease, include finasteride and minoxidil. Also, another possible form of treatment has been the case of hair transplantation. Despite the new possible treatment options available for treatment of different types of hair loss, there is a need for the invention for more efficient management and treatment options that are less costly, environmentally friendly, and most importantly human consumption friendly. Due to the recent evaluation that low-level laser therapy stimulated hair growth. This systematic review and meta-analysis was to determine whether the use of low-level laser therapy is an effective therapy for treatment of the Androgenic alopecia and also to some degree we reviewed the level of the patient's satisfaction. Some earlier studies had shown that the use of low-level laser therapy stimulated the hair growth when mice were treated with chemotherapy which was induced by the alopecia and also the other type of alopecia called alopecia areata. The researchers hypothesized that the primary mechanism of treating Androgenic alopecia to be the stimulation of the epidermal stem cells which are in the hair follicle making them bulge and shift the follicles into the anagen phase.

  7. Wafer-level vacuum packaged resonant micro-scanning mirrors for compact laser projection displays

    Science.gov (United States)

    Hofmann, Ulrich; Oldsen, Marten; Quenzer, Hans-Joachim; Janes, Joachim; Heller, Martin; Weiss, Manfred; Fakas, Georgios; Ratzmann, Lars; Marchetti, Eleonora; D'Ascoli, Francesco; Melani, Massimiliano; Bacciarelli, Luca; Volpi, Emilio; Battini, Francesco; Mostardini, Luca; Sechi, Francesco; De Marinis, Marco; Wagner, Bernd

    2008-02-01

    Scanning laser projection using resonant actuated MEMS scanning mirrors is expected to overcome the current limitation of small display size of mobile devices like cell phones, digital cameras and PDAs. Recent progress in the development of compact modulated RGB laser sources enables to set up very small laser projection systems that become attractive not only for consumer products but also for automotive applications like head-up and dash-board displays. Within the last years continuous progress was made in increasing MEMS scanner performance. However, only little is reported on how mass-produceability of these devices and stable functionality even under harsh environmental conditions can be guaranteed. Automotive application requires stable MEMS scanner operation over a wide temperature range from -40° to +85°Celsius. Therefore, hermetic packaging of electrostatically actuated MEMS scanning mirrors becomes essential to protect the sensitive device against particle contamination and condensing moisture. This paper reports on design, fabrication and test of a resonant actuated two-dimensional micro scanning mirror that is hermetically sealed on wafer level. With resonant frequencies of 30kHz and 1kHz, an achievable Theta-D-product of 13mm.deg and low dynamic deformation <20nm RMS it targets Lissajous projection with SVGA-resolution. Inevitable reflexes at the vacuum package surface can be seperated from the projection field by permanent inclination of the micromirror.

  8. O efeito do laser de baixa energia no crescimento bacteriano "in vitro" Low level laser effect in "in vitro" bacterial growth

    Directory of Open Access Journals (Sweden)

    Fernando Coutinho

    2007-08-01

    Full Text Available OBJETIVO: Avaliar, por meio de estudo bacteriológico in vitro, o efeito de dois tipos de laser de baixa energia (LBE sobre diferentes populações bacterianas habitualmente presentes em feridas pós-traumáticas. MÉTODOS: Foram colhidos swabs diretamente do sítio de infecção de pacientes internados com osteomielite pós-traumática crônica. As bactérias isoladas foram Acinetobacter baumanii complex, Escherichia coli, Haemophilus influenzae, Klebsiella pneumoniae, Pseudomonas aeruginosa, Salmonela sp, Serratia sp e Staphylococcus aureus. O material coletado foi semeado em meio ágar-sangue, através de alça estéril, utilizando-se 30 placas de Petri para cada germe. Foram utilizados dois aparelhos de LBE: Ibramed Laser Pulse #01189, com 15W/904nm por 200 segundos, e Phisiolux dual Bioset #9909001, com 20W/904nm por 230 segundos. Nos grupos I (n = 10 e II (n = 10, as bactérias sofreram irradiação pelo laser. O grupo III (n = 10 serviu de controle, não sendo irradiado. As bactérias dos grupos I e II foram irradiadas em câmara de fluxo laminar, previamente esterilizada por raio ultravioleta. O laser foi administrado de forma direta, central e perpendicularmente à superfície de cultivo das bactérias, com distância-padrão de 1cm, através de orifício confeccionado na tampa das placas. O crescimento bacteriano foi analisado após 12 e 24 horas da irradiação. Os resultados foram processados estatisticamente, utilizando-se o teste não-paramétrico de Kruskall-Wallis, com nível de significância p OBJECTIVE: To perform an in vitro bacteriologic study to evaluate the effect of two types of low level laser (LLL on different bacterial populations usually present in post-traumatic wounds. METHODS: Swabs were prepared directly at the infection site of patients hospitalized with chronic post-traumatic osteomyelitis. Isolated bacteria were Acinetobacter baumanii complex, Escherichia coli, Haemophilus influenzae, Klebsiella pneumoniae

  9. The Use of Thought Experiments in Teaching Physics to Upper Secondary-Level Students: Two Examples from the Theory of Relativity

    Science.gov (United States)

    Velentzas, Athanasios; Halkia, Krystallia

    2013-01-01

    The present study focuses on the way thought experiments (TEs) can be used as didactical tools in teaching physics to upper secondary-level students. A qualitative study was designed to investigate to what extent the TEs called "Einstein's elevator" and "Einstein's train" can function as tools in teaching basic concepts of the…

  10. New photoionization lasers pumped by laser-induced plasma radiation

    International Nuclear Information System (INIS)

    Hube, M.; Dieckmann, M.; Beigang, R.; Welling, H.; Wellegehausen, B.

    1988-01-01

    Innershell photoionization of atomic gases and vapors by soft x rays from a laser-produced plasma is a potential method for making lasers at short wavelengths. Normally, in such experiments only a single plasma spot or plasma line is created for the excitation. This gives high excitation rates but only a short excitation length. At high excitation rates detrimental influences, such as amplified spontaneous emission, optical saturation, or quenching processes, may decrease or even destroy a possible inversion. Therefore, it seems to be more favorable to use a number of separated plasma spots with smaller excitation rates and larger excitation lengths. As a test, a three-plasma spot device was constructed and used in the well-known Cd-photoionization laser at 442 nm. With a 600-mJ Nd:YAH laser (pulse length, 8 ns) for plasma production, output energies up to 300 μJ have been measured, which is more than a doubling of so far obtained data. On innershell excitation, levels may be populated that allow direct lasers as in the case of Cd or that are metastable and cannot be directly coupled to lower levels. In this case modifications in the excitation process are necessary. Such modifications may be an optical pump process in the atom prior to the innershell photoionization or an optical pump process (population transfer process) after the innershell ionization, leading to Raman or anti-Stokes Raman-type laser emissions. With these techniques and the developed multiplasma spot excitation device a variety of new laser emissions in K and Cs ions have been achieved which are indicated in the level schemes

  11. An Experimental Study on Micro Clinching of Metal Foils with Cutting by Laser Shock Forming.

    Science.gov (United States)

    Wang, Xiao; Li, Cong; Ma, Youjuan; Shen, Zongbao; Sun, Xianqing; Sha, Chaofei; Gao, Shuai; Li, Liyin; Liu, Huixia

    2016-07-13

    This paper describes a novel technique for joining similar and dissimilar metal foils, namely micro clinching with cutting by laser shock forming. A series of experiments were conducted to study the deformation behavior of single layer material, during which many important process parameters were determined. The process window of the 1060 pure aluminum foils and annealed copper foils produced by micro clinching with cutting was analyzed. Moreover, similar material combination (annealed copper foils) and dissimilar material combination (1060 pure aluminum foils and 304 stainless steel foils) were successfully achieved. The effect of laser energy on the interlock and minimum thickness of upper foils was investigated. In addition, the mechanical strength of different material combinations joined by micro clinching with cutting was measured in single lap shearing tests. According to the achieved results, this novel technique is more suitable for material combinations where the upper foil is thicker than lower foil. With the increase of laser energy, the interlock increased while the minimum thickness of upper foil decreased gradually. The shear strength of 1060 pure aluminum foils and 304 stainless steel foils combination was three times as large as that of 1060 pure aluminum foils and annealed copper foils combination.

  12. Can combined use of low-level lasers and hyaluronic acid injections prolong the longevity of degenerative knee joints?

    Directory of Open Access Journals (Sweden)

    Ip D

    2015-08-01

    Full Text Available David Ip, Nga Yue FuAsia Medical Pain Centre, Grand Plaza, Mong Kok, Hong KongBackground: This study evaluated whether half-yearly hyaluronic acid injection together with low-level laser therapy in addition to standard conventional physical therapy can successfully postpone the need for joint replacement surgery in elderly patients with bilateral symptomatic tricompartmental knee arthritis.Methods: In this prospective, double-blind, placebo-controlled study, 70 consecutive unselected elderly patients with bilateral tricompartmental knee arthritis were assigned at random to either one of two conservative treatment protocols to either one of the painful knees. Protocol A consisted of conventional physical therapy plus a sham light source plus saline injection, and protocol B consisted of protocol A with addition of half-yearly hyaluronic acid injection as well as low-level laser treatment instead of using saline and a sham light source. Treatment failure was defined as breakthrough pain necessitating joint replacement.Results: Among the 140 painful knees treated with either protocol A or protocol B, only one of the 70 painful knees treated by protocol B required joint replacement, whereas 15 of the 70 painful knees treated by protocol A needed joint replacement surgery (P<0.05.Conclusion: We conclude that half-yearly hyaluronic acid injections together with low-level laser therapy should be incorporated into the standard conservative treatment protocol for symptomatic knee arthritis, because it may prolong the longevity of the knee joint without the need for joint replacement.Keywords: knee osteoarthritis, hyaluronic acid injection, low-level laser, outcome

  13. Double pulse laser ablation and plasma: Laser induced breakdown spectroscopy signal enhancement

    International Nuclear Information System (INIS)

    Babushok, V.I.; DeLucia, F.C.; Gottfried, J.L.; Munson, C.A.; Miziolek, A.W.

    2006-01-01

    A review of recent results of the studies of double laser pulse plasma and ablation for laser induced breakdown spectroscopy applications is presented. The double pulse laser induced breakdown spectroscopy configuration was suggested with the aim of overcoming the sensitivity shortcomings of the conventional single pulse laser induced breakdown spectroscopy technique. Several configurations have been suggested for the realization of the double pulse laser induced breakdown spectroscopy technique: collinear, orthogonal pre-spark, orthogonal pre-heating and dual pulse crossed beam modes. In addition, combinations of laser pulses with different wavelengths, different energies and durations were studied, thus providing flexibility in the choice of wavelength, pulse width, energy and pulse sequence. The double pulse laser induced breakdown spectroscopy approach provides a significant enhancement in the intensity of laser induced breakdown spectroscopy emission lines up to two orders of magnitude greater than a conventional single pulse laser induced breakdown spectroscopy. The double pulse technique leads to a better coupling of the laser beam with the plasma plume and target material, thus providing a more temporally effective energy delivery to the plasma and target. The experimental results demonstrate that the maximum effect is obtained at some optimum separation delay time between pulses. The optimum value of the interpulse delay depends on several factors, such as the target material, the energy level of excited states responsible for the emission, and the type of enhancement process considered. Depending on the specified parameter, the enhancement effects were observed on different time scales ranging from the picosecond time level (e.g., ion yield, ablation mass) up to the hundred microsecond level (e.g., increased emission intensity for laser induced breakdown spectroscopy of submerged metal target in water). Several suggestions have been proposed to explain

  14. Grain size analysis of sediments from the northern Andaman Sea: Comparison of laser diffraction and sieve-pipette techniques

    Digital Repository Service at National Institute of Oceanography (India)

    Ramaswamy, V.; Rao, P.S.

    measured with laser diffraction show that 99% of the particles have an upper size range between 4.8 and 7.7 mu m. A calibration relationship between pipette and laser diffraction techniques has been developed for the northern Andaman Sea. A clay particle...

  15. The theory of stability, bistability, and instability in three-mode class-A lasers

    International Nuclear Information System (INIS)

    Jahanpanah, J; Rahdar, A A

    2014-01-01

    Instability is an inevitable and common problem in all different kinds of lasers when they are oscillating in both single-and multi-mode states. Here, the stability conditions are investigated for a three-mode class-A laser. A set of linear equations is derived for the stable oscillation of the cavity central mode together with its left and right adjacent longitudinal modes. The coefficient determinant of stability equations is Hermitian and equal to zero for the roots of two diagonal arrays. In other words, the novelty of our work is to expand the stability coefficient determinant in terms of main diagonal arrays rather than for one row or one column. These diagonal roots lead to two lower and upper boundary curves in the form of a bifurcation. The lower boundary curve mimics the single-mode laser and delimits the instability region (with no above-threshold oscillating mode) from the bistability region (with two above-threshold oscillating modes). The upper boundary curve mimics the two-mode laser and delimits the bistability region from the stability region, in which all three-longitudinal modes are simultaneously oscillating in the above-threshold state. (paper)

  16. Detection and Analytical Capabilities for Trace Level of Carbon in High-Purity Metals by Laser-Induced Breakdown Spectroscopy with a Frequency Quintupled 213 nm Nd:YAG Laser

    Directory of Open Access Journals (Sweden)

    Masaki Ohata

    2017-01-01

    Full Text Available The laser-induced breakdown spectroscopy (LIBS with a frequency quintupled 213 nm Nd:YAG laser was examined to the analysis of trace level of carbon (C in high-purity metals and its detection and analytical capabilities were evaluated. Though C signal in a wavelength of 247.9 nm, which showed the highest sensitivity of C, could be obtained from Cd, Ti, and Zn ca. 7000 mg kg−1 C in Fe could not be detected due to the interferences from a lot of Fe spectra. Alternative C signal in a wavelength of 193.1 nm could not be also detected from Fe due to the insufficient laser output energy of the frequency quintupled 213 nm Nd:YAG laser. The depth analysis of C by LIBS was also demonstrated and the C in Cd and Zn was found to be contaminated in only surface area whereas the C in Ti was distributed in bulk. From these results, the frequency quintupled 213 nm Nd:YAG laser, which was adopted widely as a commercial laser ablation (LA system coupled with inductively coupled plasma mass spectrometry (ICPMS for trace element analysis in solid materials, could be used for C analysis to achieve simultaneous measurements for both C and trace elements in metals by LIBS and LA-ICPMS, respectively.

  17. Incorporating Inquiry into Upper-Level Undergraduate Homework Assignments: The Mini-Journal

    Science.gov (United States)

    Whittington, Alan; Speck, Angela; Witzig, Stephen; Abell, Sandra

    2010-05-01

    The US National Science Education Standards (2000) state that science should be taught through inquiry. The five essential features of classroom inquiry are that the leaner (i) engages in scientifically oriented questions, (ii) gives priority to evidence in responding to questions, (iii) formulates explanations from evidence, (iv) connects explanations to scientific knowledge, and (v) communicates and justifies explanations. One difficulty in achieving this vision at the university level lies in the common perception that inquiry be fully open and unstructured, and that its implementation will be impractical due to time and material constraints. In an NSF-funded project, "CUES: Connecting Undergraduates to the Enterprise of Science," faculty developed new inquiry-based laboratory curriculum materials using a "mini-journal" approach, which is designed as an alternative to the cookbook laboratory and represents the way that scientists do science. Here we adapt this approach to a homework assignment in an upper-level Planetary Science class, and show that inquiry is achievable in this setting. Traditional homeworks in this class consisted of problem sets requiring algebraic manipulation, computation, and in most cases an appraisal of the result Longer questions are broken down into chunks worth 1 to 4 points. In contrast, the mini-journal is a short article that is modeled in the way that scientists do and report science. It includes a title, abstract, introduction (with clear statement of the problem to be tackled), a description of the methods, results (presented as both tables and graphs), a discussion (with suggestions for future work) and a list of cited work. Students devise their research questions and hypothesis from the paper based on a logical next step in the investigation. Guiding questions in the discussion can assist the students ("it would be interesting to evaluate the effect of ..."). Students submit their own minijournal, using the same journal

  18. Immunological indices of blood and interstitial fluid in estimation of a program of therapy of upper limb secondary edemas

    International Nuclear Information System (INIS)

    Kuz'mina, E.G.; Degtyareva, A.A.; Doroshenko, L.N.; Rogova, N.M.; Zorina, L.N.

    1990-01-01

    The efficacy of therapy of upper limb secondary edemas after 4 programs was compared among 83 patients. The methods were as follows: traditional method (TM) including routine conservative therapy, acupuncture (AP), He-Ne laser OKG-13 and semiconductor laser against a background of traditional therapy. A study was made of the time course of the extent of edema, total protein, IG, G, A and M and circulating immune complexes (CIC) during therapy of such patients. Blood serum and interstitial fluid indices were compared. It was shown that the application of both lasers led to increasing efficacy of TM and AP

  19. Aqueous transforming growth factor-beta-I levels in rabbit eyes after excimer laser photoablation.

    Science.gov (United States)

    Bilgihan, K; Gürelik, G; Okur, H; Bilgihan, A; Hasanreisoglu, B; Imir, T

    1997-01-01

    Transforming growth factor beta (TGF-beta) plays an important role in anterior segment wound healing, by controlling the cell proliferation and differentiation, angiogenesis, extracellular matrix composition and mediating the immunosuppressive properties of the aqueous humor. The present study was undertaken to clarify the possible changes of aqueous humor TGF-betaI levels after excimer laser photoablation. Twenty-eight New Zealand rabbits were divided into four groups of 7 rabbits each. Group 1 served as control, the central 7 mm of corneal epithelium was removed in groups 2, 3 and 4. We performed 50-microm corneal photoablation in group 3, and 100-microm ablation in group 4. After 48 h we measured the TGF-betaI levels of the aqueous humor by ELISA method. The mean TGF-betaI value of the aqueous humor was found to be 162.94+/-13.73 pg/ml in the control group. Mechanical deepithelialization did not change the TGF-betaI levels of the aqueous humor (p > 0.05). There was no significant difference between the 50-microm photoablated group and the controls (p > 0.05), but the TGF-betaI levels of the 100-microm photoablated group were found to be significantly higher than those of both the control group and 50-microm photoablated group (p < 0.05). Many factors and cytokines may induce corneal haze and myopic regression after excimer laser photoablation; our study demonstrated that TGF-betaI is one of these factors and there is a positive correlation between the depth of corneal photoablation and aqueous TGF-betaI concentrations.

  20. Effects of low-level laser therapy on orthodontic tooth movement and root resorption after artificial socket preservation

    Directory of Open Access Journals (Sweden)

    Massoud Seifi

    2014-01-01

    Full Text Available Background: Low- level laser therapy has been used to stimulate the orthodontic tooth movements (OTM previously. Furthermore, in the orthodontic treatments accompanying tooth extractions, the adjacent teeth move towards the extraction sites and close the space in some cases. Then, the adjacent tooth movements must be prevented in the treatments requiring space. Laser stimulates and at some doses decelerates tooth movement; it also improves healing process and enhances osteogenesis. Hence, it can prevent movement by osteogenesis adjacent to the tooth. The present study investigated the effects of low-level laser therapy on the OTM and root resorption following artificial socket preservation. Materials and Methods: In this experimental animal trial, 16 male albino rabbits were selected with similar characteristics and randomly divided in two groups. Under general anesthesia, an artificial socket, 8 mm in height, was created in the mesial aspect of the first premolars of the rabbits and filled with demineralized freeze dried bone allograft (DFDBA. The first premolars were connected to the incisors using nickel titanium coil springs. In experimental group, gallium-aluminum-arsenide (GaAlAs laser was irritated mesial to first premolar where artificial socket was created continuously (808 nm. The cycle was 10 days irritation, 14 days rest, 10 days irritation, 14 days rest (Biostimulation mode. Control group was not laser irradiated. All animals were sacrificed after 48 days and the distance between the distal aspect of the first premolars, and the mesial surface of the second premolars was measured with leaf gauge. The specimens underwent histological assessments. Integrity of root and its resorption was observed under microscope calibration. The size of resorption lacunae was calculated in mm 2 . Normality of data was proved according to Kolmogorov-Smirnov analysis, and Student′s t-test was done. P value less than 0.05 was considered as significant

  1. The effects of low level laser irradiation on proliferation of human dental pulp: a narrative review.

    Science.gov (United States)

    Staffoli, S; Romeo, U; Amorim, R N S; Migliau, G; Palaia, G; Resende, L; Polimeni, A

    2017-01-01

    Mesenchymal stem cells (MSCs) have the capability for self-renewal, proliferation, and differentiation in various types of specialized cells, so they are very important in cellular therapies. MSC from dental pulp are simply obtainable and have high proliferative capability. Among the therapies that can stimulate the proliferation of certain cell types, low-level laser therapy (LLLT) stands out. The target of this study is to perform a literature review to investigate these effects of low-level laser irradiation on proliferation of human dental pulp.The electronic search of scientific papers was conducted in the Lilacs, Scielo, Medline and PubMed databases through scientific articles published in national and international journals in the past 20 years.The results of this review suggest that LLLT may be a useful and important tool for future advances in cell therapy and tissue engineering associated to stem cells. Studies on cell therapy for regenerating dental tissues has already been done, and shows promising results.

  2. Biostimulation effects on wheat seeds (Triticum Aestivum L) caused by low level red laser radiation with λ = 660 nm

    International Nuclear Information System (INIS)

    Hernandez, M.; Michtchenko, A.

    2009-01-01

    The principal objective is to study the biostimulation effects caused by a semiconductor low level laser radiation with ? = 660 nm on wheat seeds (Triticum Aestivum L). Seeds were treated before sowing with this laser light source. An increase in the growth of the stem of 12% with respect to control seeds was registered for seeds radiated by an intensity of 15mW/cm 2 and an irradiation time of 60 seconds. (Author)

  3. Low-level laser therapy for treatment of neurosensory disorders after orthognathic surgery: A systematic review of randomized clinical trials.

    Science.gov (United States)

    Bittencourt, M-A-V; Paranhos, L-R; Martins-Filho, P-R-S

    2017-11-01

    Low-level laser has been widely used in Dentistry and many studies have focused on its application in oral surgeries. This study was conducted with the aim of searching for scientific evidence concerning the effectiveness of laser to reduce pain or paresthesia related to orthognathic surgery. An electronic search was performed in PubMed, Scopus, Science Direct, LILACS, SciELO, CENTRAL, Google Scholar, OpenGrey, and ClinicalTrials.gov, up to November 2016, with no restrictions on language or year of publication. Additionally, a hand search of the reference list of the selected studies was carried out. The PICOS strategy was used to define the eligibility criteria and only randomized clinical trials were selected. Out of 1,257 identified citations, three papers fulfilled the criteria and were included in the systematic review. The risk of bias was assessed according to the Cochrane Guidelines for Clinical Trials and results were exposed based on a descriptive analysis. One study showed that laser therapy was effective to reduce postoperative pain 24 hours (P=0.007) and 72 hours (P=0.007) after surgery. Other study revealed the positive effect of laser to improve neurosensory recovery 60 days after surgery, evaluated also by the two-point discrimination (P=0.005) and sensory (P=0.008) tests. The third study reported an improvement for general sensibility of 68.75% for laser group, compared with 21.43% for placebo (P=0.0095), six months after surgery. Individual studies suggested a positive effect of low-level laser therapy on reduction of postoperative pain and acceleration of improvement of paresthesia related to orthognathic surgery. However, due to the insufficient number and heterogeneity of studies, a meta-analysis evaluating the outcomes of interest was not performed, and a pragmatic recommendation about the use of laser therapy is not possible. This systematic review was conducted according to the statements of PRISMA and was registered at PROSPERO under the

  4. Craterlike structures on the laser cut surface

    Science.gov (United States)

    Shulyatyev, V. B.; Orishich, A. M.

    2017-10-01

    Analysis of the laser cut surface morphology remain topical. It is related with the fact that the surface roughness is the main index of the cut quality. The present paper deals with the experimental study of the relatively unstudied type of defects on the laser cut surface, dimples, or craters. According to the measurement results, amount of craters per unit of the laser cut surface area rises as the sheet thickness rises. The crater diameter rises together with the sheet thickness and distance from the upper sheet edge. The obtained data permit concluding that the defects like craters are observed predominantly in the case of thick sheets. The results agree with the hypothesis of crater formation as impact structures resulting from the melt drops getting on the cut channel walls upon separation from the cut front by the gas flow.

  5. Average structure of the upper earth mantle and crust between Albuquerque and the Nevada Test Site

    International Nuclear Information System (INIS)

    Garbin, H.D.

    1979-08-01

    Models of Earth structures were constructed by inverting seismic data obtained from nuclear events with a 1600-m-long laser strain meter. With these models the general structure of the earth's upper mantle and crust between Albuquerque and the Nevada Test Site was determined. 3 figures, 3 tables

  6. Influence of interface roughness in quantum cascade lasers

    International Nuclear Information System (INIS)

    Krivas, K. A.; Winge, D. O.; Franckié, M.; Wacker, A.

    2015-01-01

    We use a numerical model based on non-equilibrium Green's functions to investigate the influence of interface roughness (IFR) scattering in terahertz quantum cascade lasers. We confirm that IFR is an important phenomenon that affects both current and gain. The simulations indicate that IFR causes a leakage current that transfers electrons from the upper to the lower laser state. In certain cases, this current can greatly reduce gain. In addition, individual interfaces and their impact on the renormalized single particle energies are studied and shown to give both blue- and red-shifts of the gain spectrum

  7. Improving the laser brightness of a commercial laser system

    Science.gov (United States)

    Naidoo, Darryl; Litvin, Igor; Forbes, Andrew

    2016-02-01

    We investigate the selection of a flat-top beam and a Gaussian beam inside a laser cavity on opposing mirrors. The concept is tested external to the laser cavity in a single pass and double pass regime where the latter mimics a single round trip in the laser. We implement this intra-cavity selection through the use of two 16 level diffractive optical elements. We consider a solid-state diode side-pumped laser resonator in a typical commercial laser configuration that consists of two planar mirrors where the DOEs are positioned at the mirrors. We out couple the Gaussian and flat-top distributions and we show that we improve the brightness of the laser with active mode control. We also demonstrate that the quality of the beam transformations determine the brightness improvement.

  8. Low-level laser therapy (LLLT) accelerates the sternomastoid muscle regeneration process after myonecrosis due to bupivacaine.

    Science.gov (United States)

    Alessi Pissulin, Cristiane Neves; Henrique Fernandes, Ana Angélica; Sanchez Orellana, Alejandro Manuel; Rossi E Silva, Renata Calciolari; Michelin Matheus, Selma Maria

    2017-03-01

    Because of its long-lasting analgesic action, bupivacaine is an anesthetic used for peripheral nerve block and relief of postoperative pain. Muscle degeneration and neurotoxicity are its main limitations. There is strong evidence that low-level laser therapy (LLLT) assists in muscle and nerve repair. The authors evaluated the effects of a Gallium Arsenide laser (GaAs), on the regeneration of muscle fibers of the sternomastoid muscle and accessory nerve after injection of bupivacaine. In total, 30 Wistar adult rats were divided into 2 groups: control group (C: n=15) and laser group (L: n=15). The groups were subdivided by antimere, with 0.5% bupivacaine injected on the right and 0.9% sodium chloride on the left. LLLT (GaAs 904nm, 0,05W, 2.8J per point) was administered for 5 consecutive days, starting 24h after injection of the solutions. Seven days after the trial period, blood samples were collected for determination of creatine kinase (CK). The sternomastoid nerve was removed for morphological and morphometric analyses; the surface portion of the sternomastoid muscle was used for histopathological and ultrastructural analyses. Muscle CK and TNFα protein levels were measured. The anesthetic promoted myonecrosis and increased muscle CK without neurotoxic effects. The LLLT reduced myonecrosis, characterized by a decrease in muscle CK levels, inflammation, necrosis, and atrophy, as well as the number of central nuclei in the muscle fibers and the percentage of collagen. TNFα values remained constant. LLLT, at the dose used, reduced fibrosis and myonecrosis in the sternomastoid muscle triggered by bupivacaine, accelerating the muscle regeneration process. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Evaluation of C-reactive protein, Haptoglobin and cardiac troponin 1 levels in brachycephalic dogs with upper airway obstructive syndrome

    Directory of Open Access Journals (Sweden)

    Planellas Marta

    2012-08-01

    Full Text Available Abstract Background Brachycephalic dogs have unique upper respiratory anatomy with abnormal breathing patterns similar to those in humans with obstructive sleep apnea syndrome (OSAS. The objective of this study was to evaluate the correlation between anatomical components, clinical signs and several biomarkers, used to determine systemic inflammation and myocardial damage (C-reactive protein, CRP; Haptoglobin, Hp; cardiac troponin I, cTnI, in dogs with brachycephalic upper airway obstructive syndrome (BAOS. Results Fifty brachycephalic dogs were included in the study and the following information was studied: signalment, clinical signs, thoracic radiographs, blood work, ECG, components of BAOS, and CRP, Hp and cTnI levels. A high proportion of dogs with BAOS (88% had gastrointestinal signs. The prevalence of anatomic components of BAOS was: elongated soft palate (100%, stenotic nares (96%, everted laryngeal saccules (32% and tracheal hypoplasia (29.1%. Increased serum levels of biomarkers were found in a variable proportion of dogs: 14% (7/50 had values of CRP > 20 mg/L, 22.9% (11/48 had values of Hp > 3 g/L and 47.8% (22/46 had levels of cTnI > 0.05 ng/dl. Dogs with everted laryngeal saccules had more severe respiratory signs (p Conclusions According to the low percentage of patients with elevated levels of CRP and Hp, BAOS does not seem to cause an evident systemic inflammatory status. Some degree of myocardial damage may occur in dogs with BAOS that can be detected by cTnI concentration.

  10. Liquid level and temperature sensing by using dual-wavelength fiber laser based on multimode interferometer and FBG in parallel

    Science.gov (United States)

    Sun, Chunran; Dong, Yue; Wang, Muguang; Jian, Shuisheng

    2018-03-01

    The detection of liquid level and temperature based on a fiber ring cavity laser sensing configuration is presented and demonstrated experimentally. The sensing head contains a fiber Bragg grating (FBG) and a single-mode-cladding-less-single-mode multimode interferometer, which also functions as wavelength-selective components of the fiber laser. When the liquid level or temperature is applied on the sensing head, the pass-band peaks of both multimode interference (MMI) filter and FBG filter vary and the two output wavelengths of the laser shift correspondingly. In the experiment, the corresponding sensitivities of the liquid level with four different refractive indices (RI) in the deep range from 0 mm to 40 mm are obtained and the sensitivity enhances with the RI of the liquid being measured. The maximum sensitivity of interferometer is 106.3 pm/mm with the RI of 1.391. For the temperature measurement, a sensitivity of 10.3 pm/°C and 13.8 pm/°C are achieved with the temperature ranging from 0 °C to 90 °C corresponding to the two lasing wavelengths selective by the MMI filter and FBG, respectively. In addition, the average RI sensitivity of 155.77 pm/mm/RIU is also obtained in the RI range of 1.333-1.391.

  11. High energy HF pulsed lasers

    International Nuclear Information System (INIS)

    Patterson, E.L.; Gerber, R.A.

    1976-01-01

    Recent experiments show that pulsed HF lasers are capable of producing high energy with good efficiency. Preliminary experiments show that the laser radiation from the high-gain medium can be controlled with a low-power probe laser beam or with low-level feedback. These results indicate that the HF laser may have potential for second-generation laser fusion experiments

  12. Effects of low-energy laser irradiation on the distalization velocity during experimental canine tooth movement in humans: 'comparative clinical study'; Efeitos da irradiacao com laser em baixa intensidade na velocidade de distalizacao de caninos durante a movimentacao ortodontica: 'estudo clinico comparativo'

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, Delma Rebelo

    2003-07-01

    This research investigated the effects of low level laser therapy (LLLT) upon the velocity of canine tooth movement and consequently bone remodeling. A total of eleven patients were treated with a 780 nm diode laser. One side of the upper arcade was considered control group and was not irradiated but received mechanical activation every thirty days. The opposite side received the same mechanical activation but was also irradiated at days 0, 3, 7 and 14 of each month. Data of the biometrical progress were taken on both sides on days 3,7,14,21 and 30 of each month. The results indicate that all patients showed significant acceleration of the distalization velocity on the side treated with LLLT when compared to the control. (author)

  13. Design strategy for terahertz quantum dot cascade lasers.

    Science.gov (United States)

    Burnett, Benjamin A; Williams, Benjamin S

    2016-10-31

    The development of quantum dot cascade lasers has been proposed as a path to obtain terahertz semiconductor lasers that operate at room temperature. The expected benefit is due to the suppression of nonradiative electron-phonon scattering and reduced dephasing that accompanies discretization of the electronic energy spectrum. We present numerical modeling which predicts that simple scaling of conventional quantum well based designs to the quantum dot regime will likely fail due to electrical instability associated with high-field domain formation. A design strategy adapted for terahertz quantum dot cascade lasers is presented which avoids these problems. Counterintuitively, this involves the resonant depopulation of the laser's upper state with the LO-phonon energy. The strategy is tested theoretically using a density matrix model of transport and gain, which predicts sufficient gain for lasing at stable operating points. Finally, the effect of quantum dot size inhomogeneity on the optical lineshape is explored, suggesting that the design concept is robust to a moderate amount of statistical variation.

  14. Ultrastructure and Light Microscope Analysis of Intact Skin after a Varying Number of Low Level Laser Irradiations in Mice

    Directory of Open Access Journals (Sweden)

    Mamie Mizusaki Iyomasa

    2014-01-01

    Full Text Available Low level laser therapy (LLLT has been used to relieve pain, inflammation, and wound healing processes. Thus, the skin is overexposed to laser and this effect is not completely understood. This study analyzed the effects of the number of laser applications (three, six, and 10 on the intact skin of the masseteric region in mice of strain HRS/J. The animals (n=30 were equally divided into control (0 J/cm2 and irradiated (20 J/cm2, and each of these groups was further equally divided according to the number of laser applications (three, six, and 10 and underwent LLLT on alternate days. Samples were analyzed by light microscopy and transmission electron microscope (TEM. The animals receiving applications exhibited open channels more dilated between the keratinocytes and photobiomodulation effect on endothelial cells and fibroblasts by TEM. Under the light microscope after 10 laser applications, the type I collagen decreased (P<0.05 compared to the three and six applications. Under these experimental conditions, all numbers of applications provided photobiomodulatory effect on the epidermis and dermis, without damage. More studies are needed to standardize the energy density and number of applications recommended for laser therapy to have a better cost-benefit ratio associated with treatment.

  15. Clinical study on the removal of gingival melanin pigmentation: comparison between Nd:YAG laser ablation and mechanical abrasion; Estudo clinico comparativo entre as tecnicas de despigmentacao melanica gengival: laser neodimio (1064 nm) e gengivoabrasao

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Luis Mario de Melo

    2002-07-01

    Melanin pigmentation occurs as a result of excessive deposition of melanin, produced by the melanocytes present in the basal layer of the epithelium. This study compares clinical parameters such as inflammation and/or hemorrhage, healing process and re-pigmentation, caused by the Nd:YAG laser ablation and the mechanical abrasion of the melanin, by means of photographic images, taken during the first 30 days after the treatment. The patients comfort was monitored during the first ten days after the treatment using the method of the Visual Analog Scale to measure the pain. Six patients with gingival melanin pigmentation were selected. The left upper gingival quadrant was treated with the Nd:YAG laser using 125 mJ per pulse and 20 Hz, the right upper gingival quadrant received mechanical abrasion and the lower quadrants served for control. Both techniques did not result in inflammation and/or hemorrhage. The healing process was slower with the laser. Using mechanical abrasion, ali patients showed remaining pigmentation or re-pigmentation of varying intensity after a period of 30 days. With the laser 50 % of the patients did not show any re-pigmentation after this period. The pain analysis showed that the pain sensed 24 hours after the treatment with the laser is higher than using mechanical abrasion. (author)

  16. Intraperitoneal lactate/pyruvate ratio and the level of glucose and glycerol concentration differ between patients surgically treated for upper and lower perforations of the gastrointestinal tract

    DEFF Research Database (Denmark)

    Sabroe, Jonas E; Axelsen, Anne R; Ellebæk, Mark B

    2017-01-01

    collected every 4th hour for up to 7 postoperative days. Samples were analysed for concentrations of glucose, lactate, pyruvate and glycerol. RESULTS: Microdialysis results showed that patients with upper gastrointestinal tract lesions had significantly higher levels of postoperative intraperitoneal glucose...... and glycerol concentrations, as well as lower lactate/pyruvate ratios and lactate/glucose ratios. In the group with perforation of the lower gastrointestinal tract, those patients with a complicated course showed lower levels of postoperative intraperitoneal glucose concentration and glycerol concentration...... and higher lactate/pyruvate ratios and lactate/glucose ratios than those patients with an uncomplicated course. CONCLUSION: Patients with upper and lower gastrointestinal tract lesions showed differences in postoperative biomarker levels. A difference was also seen between patients with complicated...

  17. Radiological (MRI and Biochemical effects of Low Level LASER therapy in chronic Osteo arthritis in Al-Kharj, Saudi Arabia: A Randomized Control Trial

    Directory of Open Access Journals (Sweden)

    Gopal Nambi S

    2016-11-01

    Full Text Available Osteoarthritis is one of the degenerative diseases and Low level laser therapy (LLLT has been prescribed as nonoperative treatment in physiotherapy. But the available evidences of finding the radiological and biochemical effectiveness of LLLT are very few. So, the purpose of this study is to find the radiological and biochemical effect of Low level laser therapy (LLLT in the treatment of Osteoarthritis. 34 subjects who fulfilled the inclusion and exclusion criteria were divided into two groups (Active Laser group – ALG & Placebo Laser group - PLG with randomized sampling method. ALG was treated with active laser head, whereas PLG treated same like ALG but without emission of energy. Both groups were applied with kinesio tape for 4 weeks. The frequency of the treatment was three times per week for 4 weeks in both groups. Subjects were assessed at baseline, 4th and 8th week. Contact area (mm2 – medial & lateral and cartilage thickness (percentage - medial & lateral was measured by Magnetic resonance image (MRI and CTX-II (μmg/mmol was measured by urine analysis. A statistically significant (p ≤0.05 difference between both groups were noted at the period of 8 week for contact area (lateral and CTX-II and insignificant (p ≥ 0.05 difference in contact area (medial and cartilage thickness (medial & lateral were noted. In conclusion, the low level laser therapy is helpful in modifying the biochemical components and leads to make changes in the cartilage which subsequently improve the quality of life of OA patients.

  18. Laser welding and collagen crosslinks

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, K.M.; Last, J.A. [California Univ., Davis, CA (United States). Dept. of Medicine; Small, W. IV; Maitland, D.J.; Heredia, N.J.; Da Silva, L.B.; Matthews, D.L. [Lawrence Livermore National Lab., CA (United States)

    1997-02-20

    Strength and stability of laser-welded tissue may be influenced, in part, by effects of laser exposure on collagen crosslinking. We therefore studied effects of diode laser exposure (805 nm, 1-8 watts, 30 seconds) + indocyanine green dye (ICG) on calf tail tendon collagen crosslinks. Effect of ICG dye alone on crosslink content prior to laser exposure was investigated; unexpectedly, we found that ICG-treated tissue had significantly increased DHLNL and OHP, but not HLNL. Laser exposure after ICG application reduced elevated DHLNL and OHP crosslink content down to their native levels. The monohydroxylated crosslink HLNL was inversely correlated with laser output (p<0.01 by linear regression analysis). DHLNL content was highly correlated with content of its maturational product, OHP, suggesting that precursor-product relations are maintained. We conclude that: (1)ICG alone induces DHLNL and OHP crosslink formation; (2)subsequent laser exposure reduces the ICG-induced crosslinks down to native levels; (3)excessive diode laser exposure destroys normally occurring HLNL crosslinks.

  19. Effects of low-energy laser irradiation on the distalization velocity during experimental canine tooth movement in humans: 'comparative clinical study'

    International Nuclear Information System (INIS)

    Cruz, Delma Rebelo

    2003-01-01

    This research investigated the effects of low level laser therapy (LLLT) upon the velocity of canine tooth movement and consequently bone remodeling. A total of eleven patients were treated with a 780 nm diode laser. One side of the upper arcade was considered control group and was not irradiated but received mechanical activation every thirty days. The opposite side received the same mechanical activation but was also irradiated at days 0, 3, 7 and 14 of each month. Data of the biometrical progress were taken on both sides on days 3,7,14,21 and 30 of each month. The results indicate that all patients showed significant acceleration of the distalization velocity on the side treated with LLLT when compared to the control. (author)

  20. Laser fusion

    International Nuclear Information System (INIS)

    Eliezer, S.

    1982-02-01

    In this paper, the physics of laser fusion is described on an elementary level. The irradiated matter consists of a dense inner core surrounded by a less dense plasma corona. The laser radiation is mainly absorbed in the outer periphery of the plasma. The absorbed energy is transported inward to the ablation surface where plasma flow is created. Due to this plasma flow, a sequence of inward going shock waves and heat waves are created, resulting in the compression and heating of the core to high density and temperature. The interaction physics between laser and matter leading to thermonuclear burn is summarized by the following sequence of events: Laser absorption → Energy transport → Compression → Nuclear Fusion. This scenario is shown in particular for a Nd:laser with a wavelength of 1 μm. The wavelength scaling of the physical processes is also discussed. In addition to the laser-plasma physics, the Nd high power pulsed laser is described. We give a very brief description of the oscillator, the amplifiers, the spatial filters, the isolators and the diagnostics involved. Last, but not least, the concept of reactors for laser fusion and the necessary laser system are discussed. (author)

  1. Theoretical investigation on exciplex pumped alkali vapor lasers with sonic-level gas flow

    Science.gov (United States)

    Xu, Xingqi; Shen, Binglin; Huang, Jinghua; Xia, Chunsheng; Pan, Bailiang

    2017-07-01

    Considering the effects of higher excited and ion energy states and utilizing the methodology in the fluid mechanics, a modified model of exciplex pumped alkali vapor lasers with sonic-level flowing gas is established. A comparison of output characters between subsonic flow and supersonic flow is made. In this model, higher excited and ion energy states are included as well, which modifies the analysis of the kinetic process and introduces larger heat loading in an operating CW exciplex-pumped alkali vapor laser. The results of our calculations predict that subsonic flow has an advantage over supersonic flow under the same fluid parameters, and stimulated emission in the supersonic flow would be quenched while the pump power reaching a threshold value of the fluid choking effect. However, by eliminating the influence of fluid characters, better thermal management and higher optical conversion efficiency can be obtained in supersonic flow. In addition, we make use of the "nozzle-diffuser" to build up the closed-circle flowing experimental device and gather some useful simulated results.

  2. Sensing the upper and lower levels of the atmosphere during the 2009 equinoxes using GPS measurements

    Directory of Open Access Journals (Sweden)

    Wayan Suparta

    2014-05-01

    Full Text Available This short-term work characterized the upper and lower levels of the atmosphere through Global Positioning System (GPS measurements. The observations were conducted during the 2009 equinoxes from two pairs of conjugate polar observing stations: Husafell, Iceland (HUSA and Resolute in Nunavut, Canada (RESO and their conjugate pairs at Scott Base (SBA and Syowa (SYOG in Antarctica, respectively. The total electron content (TEC, an indicator of the upper atmosphere, and the precipitable water vapor (PWV, which served as the lower atmospheric response, were retrieved and analyzed. The results reveal a good relationship between TEC and PWV at each station during the onset day of the equinoxes, whereas an asymmetrical response was observed in the beginning of and after the equinoxes. In addition, the conjugate pairs were only consistent during the autumnal equinox. Thus, the high correlation was observed following the seasonal pattern for the onset day, while strong and moderate correlations were found only for the vernal equinox in Antarctica and the Arctic, respectively. This relationship reflects the fact that the intensity of solar activity during the solar minimum incident on the lower atmosphere through the conjugate points is associated with the variation of the Sun’s seasonal cycle, whereas the TEC and PWV showed an opposite relationship.

  3. An Experimental Study on Micro Clinching of Metal Foils with Cutting by Laser Shock Forming

    Directory of Open Access Journals (Sweden)

    Xiao Wang

    2016-07-01

    Full Text Available This paper describes a novel technique for joining similar and dissimilar metal foils, namely micro clinching with cutting by laser shock forming. A series of experiments were conducted to study the deformation behavior of single layer material, during which many important process parameters were determined. The process window of the 1060 pure aluminum foils and annealed copper foils produced by micro clinching with cutting was analyzed. Moreover, similar material combination (annealed copper foils and dissimilar material combination (1060 pure aluminum foils and 304 stainless steel foils were successfully achieved. The effect of laser energy on the interlock and minimum thickness of upper foils was investigated. In addition, the mechanical strength of different material combinations joined by micro clinching with cutting was measured in single lap shearing tests. According to the achieved results, this novel technique is more suitable for material combinations where the upper foil is thicker than lower foil. With the increase of laser energy, the interlock increased while the minimum thickness of upper foil decreased gradually. The shear strength of 1060 pure aluminum foils and 304 stainless steel foils combination was three times as large as that of 1060 pure aluminum foils and annealed copper foils combination.

  4. Terahertz lasers and amplifiers based on resonant optical phonon scattering to achieve population inversion

    Science.gov (United States)

    Williams, Benjamin S. (Inventor); Hu, Qing (Inventor)

    2009-01-01

    The present invention provides quantum cascade lasers and amplifier that operate in a frequency range of about 1 Terahertz to about 10 Terahertz. In one aspect, a quantum cascade laser of the invention includes a semiconductor heterostructure that provides a plurality of lasing modules connected in series. Each lasing module includes a plurality of quantum well structure that collectively generate at least an upper lasing state, a lower lasing state, and a relaxation state such that the upper and the lower lasing states are separated by an energy corresponding to an optical frequency in a range of about 1 to about 10 Terahertz. The lower lasing state is selectively depopulated via resonant LO-phonon scattering of electrons into the relaxation state.

  5. Underwater Near-Infrared Spectroscopy: Muscle Oxygen Changes in the Upper and Lower Extremities in Club Level Swimmers and Triathletes.

    Science.gov (United States)

    Jones, B; Cooper, C E

    2016-01-01

    To date, measurements of oxygen status during swim exercise have focused upon systemic aerobic capacity. The development of a portable, waterproof NIRS device makes possible a local measurement of muscle hemodynamics and oxygenation that could provide a novel insight into the physiological changes that occur during swim exercise. The purpose of this study was to observe changes in muscle oxygenation in the vastus lateralis (VL) and latissimus dorsi (LD) of club level swimmers and triathletes. Ten subjects, five club level swimmers and five club level triathletes (three men and seven women) were used for assessment. Swim group; mean±SD=age 21.2±1.6 years; height 170.6±7.5 cm; weight 62.8±6.9 kg; vastus lateralis skin fold 13.8±5.6 mm; latissimus dorsi skin fold 12.6±3.7. Triathlete group; mean±SD=age 44.0±10.5 years; height 171.6±7.0 cm; weight 68.6±12.7 kg; vastus lateralis skin fold 11.8±3.5 mm; latissimus dorsi skin fold 11.2±3.1. All subjects completed a maximal 200 m freestyle swim, with the PortaMon, a portable NIR device, attached to the subject's dominant side musculature. ΔTSI% between the vastus lateralis and latissimus dorsi were analysed using either paired (2-tailed) t-tests or Wilcoxon signed rank test. The level of significance for analysis was set at pswim significantly faster (p=0.04) than club level triathletes. Club level swimmers use both the upper and lower muscles to a similar extent during a maximal 200 m swim. Club level triathletes predominately use the upper body for propulsion during the same exercise. The data produced by NIRS in this study are the first of their kind and provide insight into muscle oxygenation changes during swim exercise which can indicate the contribution of one muscle compared to another. This also enables a greater understanding of the differences in swimming techniques seen between different cohorts of swimmers and potentially within individual swimmers.

  6. Comparative study of Low-level laser therapy and microcurrent on the healing of skin burns in rats

    Directory of Open Access Journals (Sweden)

    Rodrigo Pegado de Abreu Freitas

    2014-03-01

    This study investigated and compared the effects of low-level laser therapy (LLLT and microcurrent in the burn healing process in Wistar rats. We conducted a randomized controlled study with 30 rats divided into 3 groups (n = 10; control group (CG, laser group (LG and microcurrent group (MG. After thermal damage, 10 applications of 660 nm diode laser were performed in GL and 10 applications of 60 Hz microcurrent (160 μA in MG. The semi-quantitative histological analysis was done using scores (0–3, in sections stained by hematoxylin and eosin and Masson’s trichrome. The results indicated a significant improvement in the fibroblasts proliferation, collagen fibers deposition, neoangiogenesis, and cutaneous appendages regeneration in MG and LG. When microcurrent and LLLT were compared, no difference was detected, except the regeneration and formation of new cutaneous appendages, observed in MG. Despite the similar effects, GM showed faster tissue repair with the formation of skin appendages.

  7. All passive synchronized Q-switching of a quasi-three-level and a four-level Nd:YAG laser

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Tidemand-Lichtenberg, Peter; Jensen, Ole Bjarlin

    2010-01-01

    Using an all passive approach, synchronized Q-switching of two Nd:YAG lasers, at 946 nm and 1064 nm, is reported. Two laser crystals are used to avoid gain competition, and stable operation is reported for the first time. The pulse trains are synchronized over a wide range of pump powers...

  8. The Role of External Environment in Upper Echelons Theory

    DEFF Research Database (Denmark)

    Yamak, Sibel; Nielsen, Sabina; Escribá-Esteve, Alejandro

    2014-01-01

    and industrial organization theories, a cross-level conceptual model outlining the direct, mediating, and moderating effects of the external environment on upper echelons is developed. This review distinguishes between industry and institutional levels of analysis and three types of environmental characteristics......Upper echelons research has largely focused on the antecedents and consequences of top management teams (TMTs) from the team and firm levels of analysis. This paper reviews empirical research on TMTs with a specific emphasis on the role of the external environment. Applying institutional...

  9. Low-level laser therapy for the prevention of low salivary flow rate after radiotherapy and chemotherapy in patients with head and neck cancer

    International Nuclear Information System (INIS)

    Gonnelli, Fernanda Aurora Stabile; Palma, Luiz Felipe; Giordani, Adelmo Jose; Dias, Rodrigo Souza; Segreto, Roberto Araujo; Segreto, Helena Regina Comodo; Deboni, Aline Lima Silva

    2016-01-01

    Objective: to determine whether low-level laser therapy can prevent salivary hypofunction after radiotherapy and chemotherapy in head and neck cancer patients. Materials and methods: ee evaluated 23 head and neck cancer patients, of whom 13 received laser therapy and 10 received clinical care only. An InGaAlP laser was used intra-orally (at 660 nm and 40 mW) at a mean dose of 10.0 J/cm 2 and extra-orally (at 780 nm and 15 mW) at a mean dose of 3.7 J/cm 2 , three times per week, on alternate days. Stimulated and unstimulated sialometry tests were performed before the first radiotherapy and chemotherapy sessions (NO) and at 30 days after the end of treatment (N30). Results: At N30, the mean salivary flow rates were significantly higher among the laser therapy patients than among the patients who received clinical care only, in the stimulated and unstimulated sialometry tests (p = 0.0131 and p = 0.0143, respectively). Conclusion: low-level laser therapy, administered concomitantly with radiotherapy and chemotherapy, appears to mitigate treatment induced salivary hypofunction in patients with head and neck cancer. (author)

  10. Low-level laser therapy for the prevention of low salivary flow rate after radiotherapy and chemotherapy in patients with head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gonnelli, Fernanda Aurora Stabile [Faculdades Metropolitanas Unidas (FMU), Sao Paulo, SP (Brazil); Palma, Luiz Felipe; Giordani, Adelmo Jose; Dias, Rodrigo Souza; Segreto, Roberto Araujo; Segreto, Helena Regina Comodo [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Deboni, Aline Lima Silva

    2016-03-15

    Objective: to determine whether low-level laser therapy can prevent salivary hypofunction after radiotherapy and chemotherapy in head and neck cancer patients. Materials and methods: ee evaluated 23 head and neck cancer patients, of whom 13 received laser therapy and 10 received clinical care only. An InGaAlP laser was used intra-orally (at 660 nm and 40 mW) at a mean dose of 10.0 J/cm{sup 2} and extra-orally (at 780 nm and 15 mW) at a mean dose of 3.7 J/cm{sup 2} , three times per week, on alternate days. Stimulated and unstimulated sialometry tests were performed before the first radiotherapy and chemotherapy sessions (NO) and at 30 days after the end of treatment (N30). Results: At N30, the mean salivary flow rates were significantly higher among the laser therapy patients than among the patients who received clinical care only, in the stimulated and unstimulated sialometry tests (p = 0.0131 and p = 0.0143, respectively). Conclusion: low-level laser therapy, administered concomitantly with radiotherapy and chemotherapy, appears to mitigate treatment induced salivary hypofunction in patients with head and neck cancer. (author)

  11. Possibility of increasing the efficiency of laser-induced tattoo removal by optical skin clearing

    International Nuclear Information System (INIS)

    Genina, E A; Bashkatov, A N; Tuchin, V V; Yaroslavskii, I V; Altshuler, G B

    2008-01-01

    The possibility of selective laser photothermolysis improvement for the removal of tattoo pigments due to the optical clearing of human skin is investigated. It is shown experimentally that the optical skin clearing increases the tattoo image contrast. Computer Monte Carlo simulations show that by decreasing the laser beam scattering in upper skin layers, it is possible to reduce the radiation power required for tattoo removal by 30%-40% and, therefore, to increase the the photothermolysis efficiency. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

  12. In vitro analysis of low-level laser irradiation on human osteoblast-like cells proliferation

    Science.gov (United States)

    Bloise, Nora; Saino, Enrica; Bragheri, Francesca; Minzioni, Paolo; Cristiani, Ilaria; Imbriani, Marcello; Visai, Livia

    2011-07-01

    The objective of this study was to examine the in vitro effect of a single or a multiple doses of low-level laser irradiation (LLLI) on proliferation of the human osteosarcoma cell line, SAOS-2. SAOS-2 cells were divided in five groups and exposed to LLLI (659 nm diode laser; 11 mW power output): group I as a control (dark), group II exposed to a single laser dose of 1 J/cm2, group III irradiated with a single dose of 3 J/cm2, and group IV and V exposed for three consecutive days to 1 or 3 J/cm², respectively. Cellular proliferation was assessed daily up to 7 days of culturing. The obtained results showed an increase in proliferative capacity of SAOS-2 cells during the first 96 h of culturing time in once-irradiated cells, as compared to control cells. Furthermore, a significantly higher proliferation in the group IV and V was detected if compared to a single dose or to control group after 96 h and 7 days. In conclusion, the effect of the single dose on cell proliferation was transitory and repeated irradiations were necessary to observe a strong enhancement of SAOS-2 growth. As a future perspective, we would like to determine the potential of LLLI as a new approach for promoting bone regeneration onto biomaterials.

  13. Diode lasers optimized in brightness for fiber laser pumping

    Science.gov (United States)

    Kelemen, M.; Gilly, J.; Friedmann, P.; Hilzensauer, S.; Ogrodowski, L.; Kissel, H.; Biesenbach, J.

    2018-02-01

    In diode laser applications for fiber laser pumping and fiber-coupled direct diode laser systems high brightness becomes essential in the last years. Fiber coupled modules benefit from continuous improvements of high-power diode lasers on chip level regarding output power, efficiency and beam characteristics resulting in record highbrightness values and increased pump power. To gain high brightness not only output power must be increased, but also near field widths and far field angles have to be below a certain value for higher power levels because brightness is proportional to output power divided by beam quality. While fast axis far fields typically show a current independent behaviour, for broadarea lasers far-fields in the slow axis suffer from a strong current and temperature dependence, limiting the brightness and therefore their use in fibre coupled modules. These limitations can be overcome by carefully optimizing chip temperature, thermal lensing and lateral mode structure by epitaxial and lateral resonator designs and processing. We present our latest results for InGaAs/AlGaAs broad-area single emitters with resonator lengths of 4mm emitting at 976nm and illustrate the improvements in beam quality over the last years. By optimizing the diode laser design a record value of the brightness for broad-area lasers with 4mm resonator length of 126 MW/cm2sr has been demonstrated with a maximum wall-plug efficiency of more than 70%. From these design also pump modules based on 9 mini-bars consisting of 5 emitters each have been realized with 360W pump power.

  14. Laser resonant ionization spectroscopy and laser-induced resonant fluorescence spectra of samarium atom

    International Nuclear Information System (INIS)

    Jin, Changtai

    1995-01-01

    We have measured new high-lying levels of Sm atom by two-colour resonant photoionisation spectroscopy; we have observed the isotope shifts of Sm atom by laser-induced resonant fluorescence spectroscopy; the lifetime of eight low-lying levels of Sm atom were measured by using pulsed laser-Boxcar technique in atomic beam.

  15. Application of the UV laser printing technique to soft gelatin capsules containing titanium dioxide in the shells.

    Science.gov (United States)

    Hosokawa, Akihiro; Kato, Yoshiteru

    2012-03-01

    The purpose of this study was to examine application of ultraviolet (UV) laser irradiation to printing soft gelatin capsules containing titanium dioxide (TiO(2)) in the shells and to study effect of UV laser power on the color strength of printing on the soft gelatin capsules. Size 6 Oval type soft gelatin capsules of which shells contained 0.685% TiO(2) and 0.005% ferric dioxide were used in this study. The capsules were irradiated pulsed UV laser at a wavelength 355 nm. The color strength of the printed capsules was determined by a spectrophotometer as total color difference (dE). The soft gelatin capsules which contained TiO(2) in the shells could be printed gray by the laser. Many black particles, which were associated with the printing, were formed at the colored parts of the shells. It was found that there were two inflection points in relationship between output laser energy of a pulse and dE. Below the lower point, the capsules were not printed. From the lower point to the upper point, the capsules were printed gray and total color difference of the printing increased linearly in proportion with the output laser energy. Beyond the upper point, total color difference showed saturation because of micro-bubbles formation at the laser irradiated spot. Soft gelatin capsules containing TiO(2) in the shells could be performed stable printing using the UV laser printing technique. Color strength of the printing could be controlled by regulating the laser energy between the two inflection points.

  16. Transient thermal analysis of semiconductor diode lasers under pulsed operation

    Science.gov (United States)

    Veerabathran, G. K.; Sprengel, S.; Karl, S.; Andrejew, A.; Schmeiduch, H.; Amann, M.-C.

    2017-02-01

    Self-heating in semiconductor lasers is often assumed negligible during pulsed operation, provided the pulses are `short'. However, there is no consensus on the upper limit of pulse width for a given device to avoid-self heating. In this paper, we present an experimental and theoretical analysis of the effect of pulse width on laser characteristics. First, a measurement method is introduced to study thermal transients of edge-emitting lasers during pulsed operation. This method can also be applied to lasers that do not operate in continuous-wave mode. Secondly, an analytical thermal model is presented which is used to fit the experimental data to extract important parameters for thermal analysis. Although commercial numerical tools are available for such transient analyses, this model is more suitable for parameter extraction due to its analytical nature. Thirdly, to validate this approach, it was used to study a GaSb-based inter-band laser and an InP-based quantum cascade laser (QCL). The maximum pulse-width for less than 5% error in the measured threshold currents was determined to be 200 and 25 ns for the GaSb-based laser and QCL, respectively.

  17. Effect of Low-level LASER Therapy on P6 Acupoint to Control Gag Reflex in Children: A Clinical Trial

    Directory of Open Access Journals (Sweden)

    Himani Goel

    2017-10-01

    Conclusion: LLLT on PC6 point was found to be effective in lowering anxiety levels as observed by faces modified anxiety rating scale. Further, it was authenticated as the pulse rates were significantly reduced and oxygen saturation levels were significantly increased. Also, gag reflex was significantly controlled when LASER stimulation was done at PC6.

  18. Stabilizing laser energy density on a target during pulsed laser deposition of thin films

    Science.gov (United States)

    Dowden, Paul C.; Jia, Quanxi

    2016-05-31

    A process for stabilizing laser energy density on a target surface during pulsed laser deposition of thin films controls the focused laser spot on the target. The process involves imaging an image-aperture positioned in the beamline. This eliminates changes in the beam dimensions of the laser. A continuously variable attenuator located in between the output of the laser and the imaged image-aperture adjusts the energy to a desired level by running the laser in a "constant voltage" mode. The process provides reproducibility and controllability for deposition of electronic thin films by pulsed laser deposition.

  19. Pulsed Laser Centre (CLPU). The Salamanca peta watt laser; Centro de Laseres Pulsados (CLPU). El laser de Petavatio de Salamanca

    Energy Technology Data Exchange (ETDEWEB)

    Franco, L. R.

    2016-08-01

    With pulses lasting 30 photo seconds, the CLPU VEGA laser is capable of generating a peak power level of one peta watt, this making it one of the worlds most powerful lasers. When focussed it can reach extreme intensities. The way in which a pulse of this nature interacts with an atom or what its applications might be are among the questions answered by this article. (Author)

  20. Effect of 940 nm low-level laser therapy on osteogenesis in vitro

    Science.gov (United States)

    Jawad, Mohammed Mahmood; Husein, Adam; Azlina, Ahmad; Alam, Mohammad Khursheed; Hassan, Rozita; Shaari, Rumaizi

    2013-12-01

    Bone regeneration is essential in medical treatment, such as in surgical bone healing and orthodontics. The aim of this study is to examine the effect of different powers of 940 nm diode low-level laser treatment (LLLT) on osteoblast cells during their proliferation and differentiation stages. A human fetal osteoblast cell line was cultured and treated with LLLT. The cells were divided into experimental groups according to the power delivered and periods of exposure per day for each laser power. The (3-(4,5-dimethylthiazol-2yl)-2,5 diphenyl tetrazolium bromide) (MTT) assay was used to determine cell proliferation. Both alkaline phosphatase and osteocalcin activity assays were assessed for cell differentiation. All treatment groups showed a significant increase in cell proliferation and differentiation compared to the control group. Regarding the exposure time, the subgroups treated with the LLLT for 6 min showed higher proliferation and differentiation rates for the powers delivered, the 300-mW LLLT group significantly increased the amount of cell proliferation. By contrast, the 100 and 200 mW groups showed significantly greater amounts of cell differentiation. These results suggest that the use of LLLT may play an important role in stimulating osteoblast cells for improved bone formation.

  1. Confirmation of radiation pressure effects in laser--plasma interactions

    International Nuclear Information System (INIS)

    Attwood, D.T.; Sweeney, D.W.; Auerbach, J.M.; Lee, P.H.Y.

    1977-10-01

    Interferometric data resolved in 1μm and 15 psec confirms the dominant role of radiation pressure during high intensity laser-plasma interactions. Specifically observed manifestations include electron density profiles steepened to 1 μm scale length, clearly defined upper and lower density shelves, and small and large scale deformation of transverse isodensity surfaces

  2. Effect of Carbon Dioxide Laser on Increasing Vestibular Depth in Cleft Lip and Palate Patients.

    Science.gov (United States)

    Yassaei, Sogra; Aghili, Hossein; Azam, Alireza Navab; Moghadam, Mahjobeh Gholdani; Safari, Isa

    2017-09-01

    Shallow upper buccal sulcus deformity in cleft lip and palate patients is one of the common secondary deformities after primary cleft lip and palate repair; this deformity may prevent or complicate orthodontic and prosthodontic procedures causing aesthetic and functional problems. A number of methods are described to increase the anterior maxillary sulcus in these patients. This study assessed the use of a carbon dioxide laser (CO 2 ) to increase the sulcus depth. Fifteen patients with cleft lip and palate (eight unilateral and seven bilateral) were studied. The surgical procedure was performed using CO 2 laser. The vestibular depth and lip length were measured at three time points namely before surgery (T0), 1 week following surgery (T1), and 4 months following surgery (T2). After data collection, statistical analyses were done using PASW ® version 18 SPSS. The mean values of vestibular depth were 9.46 ± 1.92, 13.83 ± 1.88, and 13.23 ± 1.76 mm for T0, T1, and T2, respectively. The vestibular depth significantly increased after 4 months of follow-up (p = 0.001). The mean amount of vestibular depth gain was not significantly different in unilateral and bilateral cleft groups (p = 0.908). The mean value of upper lip length increased by a mean of 1.23 mm and was statistically significant (p = 0.001). Upper buccal sulcus reconstruction with CO 2 laser provides successful and stable results. CO 2 laser application is suggested as an alternative to conventional vestibuloplasty.

  3. Ion-atom charge-transfer system for a heavy-ion-beam pumped laser

    International Nuclear Information System (INIS)

    Ulrich, A.; Gernhaeuser, R.; Kroetz, W.; Wieser, J.; Murnick, D.E.

    1994-01-01

    An Ar target to which Cs vapor could be added, excited by a pulsed beam of 100-MeV 32 S ions, was studied as a prototype ion-atom charge-transfer system for pumping short-wavelength lasers. Low-velocity Ar 2+ ions were efficiently produced; a huge increase in the intensity of the Ar II 4d-4p spectral lines was observed when Cs vapor was added to the argon. This observation is explained by a selective charge transfer of the Cs 6s electron into the upper levels of the observed transitions. A rate constant of (1.4±0.2)x10 -9 cm 3 /s for the transfer process was determined

  4. Imprinting on empty hard gelatin capsule shells containing titanium dioxide by application of the UV laser printing technique.

    Science.gov (United States)

    Hosokawa, Akihiro; Kato, Yoshiteru; Terada, Katsuhide

    2014-08-01

    The purpose of this study was to examine the application of ultraviolet (UV) laser irradiation to printing hard gelatin capsule shells containing titanium dioxide (TiO2) and to clarify how the color strength of the printing by the laser could be controlled by the power of the irradiated laser. Hard gelatin capsule shells containing 3.5% TiO2 were used in this study. The capsules were irradiated with pulsed UV laser at a wavelength of 355 nm. The color strength of the printed capsule was determined by a spectrophotometer as total color difference (dE). The capsules could be printed gray by the UV laser. The formation of many black particles which were agglomerates of oxygen-defected TiO2 was associated with the printing. In the relationship between laser peak power of a pulse and dE, there were two inflection points. The lower point was the minimal laser peak power to form the black particles and was constant regardless of the dosage forms, for example film-coated tablets, soft gelatin capsules and hard gelatin capsules. The upper point was the minimal laser peak power to form micro-bubbles in the shells and was variable with the formulation. From the lower point to the upper point, the capsules were printed gray and the dE of the printing increased linearly with the laser peak power. Hard gelatin capsule shells containing TiO2 could be printed gray using the UV laser printing technique. The color strength of the printing could be controlled by regulating the laser energy between the two inflection points.

  5. Vestibuloplasty: a retrospective study on conventional and laser operation techniques

    Science.gov (United States)

    Neckel, Claus P.

    1999-05-01

    40 patients with edentulous maxillary jaws were referred to our private practice limited to maxillofacial surgery, due to atrophy of the alveolar ridge. Before prosthetic renewal of the upper removable prosthesis the restorative dentist requested a sufficient vestibule. After supraperiostal preparation, soft tissue advancement and fixation with absorbable sutures. The recipient site was covered with a free gingival graft. Group I was operated on traditionally using a scalpel. In group II incision and soft tissue preparation was performed using a diode laser. Wavelength: 810 nm; Continuous wave mode; 400 micron optic fiber; Output power 1.6 Watt. All operations were performed by one surgeon experienced in both operation techniques. Every patient was followed-up 1, 4, 8 weeks, 6 and 12 months. The vestibular height directly adjacent to the nasal cavity and 2cm distal to these first measuring locations were taken. Each patient was asked to evaluate their individual discomfort and postoperative pain level. Both groups showed no significant difference in vestibular height after 1, 4, 8 weeks, 6 months and 1 year. The postoperative height of 1.28 cm was reduced to 0.84 cm after 1 year. Furthermore both groups showed uneventful healing and take of the free gingival grafts. The assessment of the pain and discomfort level by the patients brought a significant difference between both groups in favor of the laser assisted operation technique.

  6. Infrared technique for decoding of invisible laser markings

    Science.gov (United States)

    Haferkamp, Heinz; Jaeschke, Peter; Stein, Johannes; Goede, Martin

    2002-03-01

    Counterfeiting and product piracy continues to be an important issue not only for the Western industry, but also for the society in general. Due to the drastic increase in product imitation and the request for plagiarism protection as well as for reducing thefts there is a high interest in new protection methods providing new security features. The method presented here consists of security markings which are included below paint layers. These markings are invisible for the human eye due to the non-transparency of the upper layers in the visible spectral range. However, the markings can be detected by an infrared technique taking advantage on the partial transparency of the upper paint layers in the IR-region. Metal sheets are marked using laser radiation. The beam of a Nd:YAG-laser provides a modification of the surface structure, resulting in dark markings due to the annealing effect. After coating of the laser-marked material, the markings are invisible for the bare eye. In order to read out the invisible information below the coating, an infrared reflection technique is used. The samples are illuminated with halogen lamps or infrared radiators. Many coating materials (i. e. paints) show a certain transparency in the mid-infrared region, especially between 3 - 5 micrometers . The reflected radiation is detected using an IR-camera with a sensitivity range from 3.4 - 5 micrometers . Due to the different reflection properties between the markings and their surrounding, the information can be detected.

  7. LaserFest Celebration

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Alan Chodos; Elizabeth A. Rogan

    2011-08-25

    LaserFest was the yearlong celebration, during 2010, of the 50th anniversary of the demonstration of the first working laser. The goals of LaserFest were: to highlight the impact of the laser in its manifold commercial, industrial and medical applications, and as a tool for ongoing scientific research; to use the laser as one example that illustrates, more generally, the route from scientific innovation to technological application; to use the laser as a vehicle for outreach, to stimulate interest among students and the public in aspects of physical science; to recognize and honor the pioneers who developed the laser and its many applications; to increase awareness among policymakers of the importance of R&D funding as evidenced by such technology as lasers. One way in which LaserFest sought to meet its goals was to encourage relevant activities at a local level all across the country -- and also abroad -- that would be identified with the larger purposes of the celebration and would carry the LaserFest name. Organizers were encouraged to record and advertise these events through a continually updated web-based calendar. Four projects were explicitly detailed in the proposals: 1) LaserFest on the Road; 2) Videos; 3) Educational material; and 4) Laser Days.

  8. Detailed Balance Limit of Efficiency of Broadband-Pumped Lasers.

    Science.gov (United States)

    Nechayev, Sergey; Rotschild, Carmel

    2017-09-13

    Broadband light sources are a wide class of pumping schemes for lasers including LEDs, sunlight and flash lamps. Recently, efficient coupling of broadband light to high-quality micro-cavities has been demonstrated for on-chip applications and low-threshold solar-pumped lasers via cascade energy transfer. However, the conversion of incoherent to coherent light comes with an inherent price of reduced efficiency, which has yet to be assessed. In this paper, we derive the detailed balance limit of efficiency of broadband-pumped lasers and discuss how it is affected by the need to maintain a threshold population inversion and thermodynamically dictated minimal Stokes' shift. We show that lasers' slope efficiency is analogous to the nominal efficiency of solar cells, limited by thermalisation losses and additional unavoidable Stokes' shift. The lasers' power efficiency is analogous to the detailed balance limit of efficiency of solar cells, affected by the cavity mirrors and impedance matching factor, respectively. As an example we analyze the specific case of solar-pumped sensitized Nd 3+ :YAG-like lasers and define the conditions to reach their thermodynamic limit of efficiency. Our work establishes an upper theoretical limit for the efficiency of broadband-pumped lasers. Our general, yet flexible model also provides a way to incorporate other optical and thermodynamic losses and, hence, to estimate the efficiency of non-ideal broadband-pumped lasers.

  9. Application of pulsed laser for evaluation and optimization of SEU-Hard Designs

    International Nuclear Information System (INIS)

    McMorrow, D.; Melinger, J.S.; Buchner, St.; Scott, T.; Brown, R.D.

    1999-01-01

    Pulsed laser SEU tests are used to pinpoint and characterize sensitive nodes of CMOS circuits and to provide feedback relevant to the development and optimization of radiation-hard designs. The present study reveals several examples of the quantitative utility of the laser system. The most direct approach to obtaining quantitative thresholds from laser SEU tests involved a calibration of the measured laser upset thresholds against heavy ion results. This procedure requires only a correlation between the laser and heavy ion measurements. This study shows that this correlation exists and is particularly strong and that the calibration factor is identical to that determined in previous studies. The laser SEU threshold energy corresponds to the most sensitive node located with the laser probe. The ion-equivalent laser LET is calculated using the calibration factor noted above. The measured heavy ion threshold is given as a range since heavy-ion upset measurements are discrete: the upper value gives the lowest LET ion to induce an upset; the lower value gives the next lower LET investigated. Laser SEU measurements often can be used directly for hardness assurance or diagnosis studies. (A.C.)

  10. Effect of modulation p-doping level on multi-state lasing in InAs/InGaAs quantum dot lasers having different external loss

    Science.gov (United States)

    Korenev, V. V.; Savelyev, A. V.; Maximov, M. V.; Zubov, F. I.; Shernyakov, Yu. M.; Kulagina, M. M.; Zhukov, A. E.

    2017-09-01

    The influence of the modulation p-doping level on multi-state lasing in InAs/InGaAs quantum dot (QD) lasers is studied experimentally for devices having various external losses. It is shown that in the case of short cavities (high external loss), there is an increase in the lasing power component corresponding to the ground-state optical transitions of QDs as the p-doping level grows. However, in the case of long cavities (small external loss), higher dopant concentrations may have an opposite effect on the output power. Based on these observations, an optimal design of laser geometry and an optimal doping level are discussed.

  11. Low-level laser therapy as a treatment for androgenetic alopecia.

    Science.gov (United States)

    Afifi, Ladan; Maranda, Eric L; Zarei, Mina; Delcanto, Gina M; Falto-Aizpurua, Leyre; Kluijfhout, Wouter P; Jimenez, Joaquin J

    2017-01-01

    Androgenetic alopecia (AGA) affects 50% of males by age 50 and 50% of females by age 80. Recently, the use of low-level laser therapy (LLLT) has been proposed as a treatment for hair loss and to stimulate hair regrowth in AGA. This paper aims to review the existing research studies to determine whether LLLT is an effective therapy for AGA based on objective measurements and patient satisfaction. A systematic literature review was done to identify articles on Medline, Google Scholar, and Embase that were published between January 1960 and November 2015. All search hits were screened by two reviewers and examined for relevant abstracts and titles. Articles were divided based on study design and assessed for risk of bias. Eleven studies were evaluated, which investigated a total of 680 patients, consisting of 444 males and 236 females. Nine out of 11 studies assessing hair count/hair density found statistically significant improvements in both males and females following LLLT treatment. Additionally, hair thickness and tensile strength significantly improved in two out of four studies. Patient satisfaction was investigated in five studies, and was overall positive, though not as profound as the objective outcomes. The majority of studies covered in this review found an overall improvement in hair regrowth, thickness, and patient satisfaction following LLLT therapy. Although we should be cautious when interpreting these findings, LLLT therapy seems to be a promising monotherapy for AGA and may serve as an effective alternative for individuals unwilling to use medical therapy or undergo surgical options. Lasers Surg. Med. 49:27-39, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Non-Topographic Space-Based Laser Remote Sensing

    Science.gov (United States)

    Yu, Anthony W.; Abshire, James B.; Riris, Haris; Purucker, Michael; Janches, Diego; Getty, Stephanie; Krainak, Michael A.; Stephen, Mark A.; Chen, Jeffrey R.; Li, Steve X.; hide

    2016-01-01

    In the past 20+ years, NASA Goddard Space Flight Center (GSFC) has successfully developed and flown lidars for mapping of Mars, the Earth, Mercury and the Moon. As laser and electro-optics technologies expand and mature, more sophisticated instruments that once were thought to be too complicated for space are being considered and developed. We will present progress on several new, space-based laser instruments that are being developed at GSFC. These include lidars for remote sensing of carbon dioxide and methane on Earth for carbon cycle and global climate change; sodium resonance fluorescence lidar to measure environmental parameters of the middle and upper atmosphere on Earth and Mars and a wind lidar for Mars orbit; in situ laser instruments include remote and in-situ measurements of the magnetic fields; and a time-of-flight mass spectrometer to study the diversity and structure of nonvolatile organics in solid samples on missions to outer planetary satellites and small bodies.

  13. High performance 40-stage and 15-stage quantum cascade lasers based on two-material active region composition

    Science.gov (United States)

    Figueiredo, P.; Suttinger, M.; Go, R.; Todi, A.; Shu, Hong; Tsvid, E.; Patel, C. Kumar N.; Lyakh, A.

    2017-05-01

    5.6μm quantum cascade lasers based on Al0.78In0.22As/In0.69Ga0.31As active region composition with measured pulsed room temperature wall plug efficiency of 28.3% are reported. Injection efficiency for the upper laser level of 75% was measured by testing devices with variable cavity length. Threshold current density of 1.7kA/cm2 and slope efficiency of 4.9W/A were measured for uncoated 3.15mm x 9µm lasers. Threshold current density and slope efficiency dependence on temperature in the range from 288K to 348K can be described by characteristic temperatures T0 140K and T1 710K, respectively. Pulsed slope efficiency, threshold current density, and wallplug efficiency for a 2.1mm x 10.4µm 15-stage device with the same design and a high reflection-coated back facet were measured to be 1.45W/A, 3.1kA/cm2 , and 18%, respectively. Continuous wave values for the same parameters were measured to be 1.42W/A, 3.7kA/cm2 , and 12%. Continuous wave optical power levels exceeding 0.5W per millimeter of cavity length was demonstrated. When combined with the 40-stage device data, the inverse slope efficiency dependence on cavity length for 15-stage data allowed for separate evaluation of the losses originating from the active region and from the cladding layers of the laser structure. Specifically, the active region losses for the studied design were found to be 0.77cm-1, while cladding region losses - 0.33cm-1. The data demonstrate that active region losses in mid wave infrared quantum cascade lasers largely define total waveguide losses and that their reduction should be one of the main priorities in the quantum cascade laser design.

  14. Changes of plasma IL-6 and TNF-α levels during peri-operative period in patients undergoing laser photo-coagulation of greater saphenous varicosities

    International Nuclear Information System (INIS)

    Wang Taihan; Wang Chunxi

    2005-01-01

    Objective: To investigate the plasma levels of IL-6 and TNF-α during peri-operative period in patients undergoing laser photocoagulation of greater saphenous varicosities. Methods: Plasma IL-6 and TNF-α levels were determined with RIA before operation and 1, 3, 7, 14 days post-operatively in 110 patients with greater saphenous vein varicosity undergoing different forms of treatment (intravascular laser photo-coagulation 43, photo-coagulation combined with venous valve repair 35, high ligation and segmental stripping 32). Skin trophic disturbances were present in 56 of the 110 patients. Plasma IL-6 and TNF-α levels were also measured in 33 controls. Results: The plasma IL-6 and TNF-α levels in patients with skin trophic disturbances were significantly higher than those in controls (P<0.01), while levels in patients without skin lesions were not much changed. The plasma IL-6 and TNF-α levels were increased at first and dropped later to approaching pre-operative value by d14 in all the 110 patients after operation, however, the amount of increase was least and the normalization was also soonest in the simple photo-coagulation group, the reverse was true for the conventional operation group. Conclusion: Laser photo-coagulation is least stressful among the three types of operation and magnitude of changes of plasma IL-6 and TNF-α levels correctly reflects the intensity of stress. (authors)

  15. Determining the Probability of Violating Upper-Level Wind Constraints for the Launch of Minuteman III Ballistic Missiles at Vandenberg Air Force Base

    Science.gov (United States)

    Shafer, Jaclyn A.; Brock, Tyler M.

    2012-01-01

    The 30th Operational Support Squadron Weather Flight (30 OSSWF) provides comprehensive weather services to the space program at Vandenberg Air Force Base (VAFB) in California. One of their responsibilities is to monitor upper-level winds to ensure safe launch operations of the Minuteman Ill ballistic missile. The 30 OSSWF tasked the Applied Meteorology Unit (AMU) to analyze VAFB sounding data with the goal of determining the probability of violating (PoV) their upper-level thresholds for wind speed and shear constraints specific to this launch vehicle, and to develop a tool that will calculate the PoV of each constraint on the day of launch. In order to calculate the probability of exceeding each constraint, the AMU collected and analyzed historical data from VAFB. The historical sounding data were retrieved from the National Oceanic and Atmospheric Administration Earth System Research Laboratory archive for the years 1994-2011 and then stratified into four sub-seasons: January-March, April-June, July-September, and October-December. The AMU determined the theoretical distributions that best fit the maximum wind speed and maximum wind shear datasets and applied this information when calculating the averages and standard deviations needed for the historical and real-time PoV calculations. In addition, the AMU included forecast sounding data from the Rapid Refresh model. This information provides further insight for the launch weather officers (LWOs) when determining if a wind constraint violation will occur over the next few hours on the day of launch. The AMU developed an interactive graphical user interface (GUI) in Microsoft Excel using Visual Basic for Applications. The GUI displays the critical sounding data easily and quickly for LWOs on day of launch. This tool will replace the existing one used by the 30 OSSWF, assist the LWOs in determining the probability of exceeding specific wind threshold values, and help to improve the overall upper winds forecast for

  16. Effects of corticopuncture (CP) and low-level laser therapy (LLLT) on the rate of tooth movement and root resorption in rats using micro-CT evaluation.

    Science.gov (United States)

    Suzuki, Selly Sayuri; Garcez, Aguinaldo Silva; Reese, Patricia Oblitas; Suzuki, Hideo; Ribeiro, Martha Simões; Moon, Won

    2018-05-01

    The aim of this study was to compare the rate of tooth displacement, quantity of root resorption, and alveolar bone changes in five groups: corticopuncture (CP), low-level laser therapy (LLLT), CP combined with LLLT (CP + LLLT), control (C), and negative control (NC). A total of 60 half-maxilla from 30 male Wistar rats (10 weeks old) were divided randomly into five groups: three (CP, LLLT, and CP + LLLT) test groups with different stimulation for accelerated-tooth-movement (ATM), one control (C) group, and one negative control (NC) group with no tooth movement. Nickel-titanium coil springs with 50 g of force were tied from the upper left and right first molars to micro-implants placed behind the maxillary incisors. For the CP and CP + LLLT groups, two perforations in the palate and one mesially to the molars were performed. For the LLLT and CP + LLLT groups, GaAlAs diode laser was applied every other day for 14 days (810 nm, 100 mW, 15 s). The tooth displacements were measured directly from the rat's mouth and indirectly from microcomputer (micro-CT) tomographic images. Bone responses at the tension and compression sites and root resorption were analyzed from micro-CT images. The resulting alveolar bone responses were evaluated by measuring bone mineral density (BMD), bone volume fraction (BV/TV), and trabecular thickness (TbTh). Root resorption crater volumes were measured on both compression and tension sides of mesial and distal buccal roots. The tooth displacement in the CP + LLLT group was the greatest when measured clinically, followed by the CP, LLLT, and control groups (C and NC), respectively (p CP and CP + LLLT groups compared to the LLLT and control groups. The BMD, BV/TV, and TbTh values were lower at the compression side and higher at the tension side for all three test groups compared to the control group. The root resorption crater volume of the distal buccal root was higher in the control group, followed by CP, LLLT

  17. Sub-parts-per-quadrillion-level graphite furnace atomic absorption spectrophotometry based on laser wave mixing.

    Science.gov (United States)

    Mickadeit, Fritz K; Berniolles, Sandrine; Kemp, Helen R; Tong, William G

    2004-03-15

    Nonlinear laser wave mixing in a common graphite furnace atomizer is presented as a zeptomole-level, sub-Doppler, high-resolution atomic absorption spectrophotometric method. A nonplanar three-dimensional wave-mixing optical setup is used to generate the signal beam in its own space. Signal collection is efficient and convenient using a template-based optical alignment. The graphite furnace atomizer offers advantages including fast and convenient introduction of solid, liquid, or gas analytes, clean atomization environment, and minimum background noise. Taking advantage of the unique features of the wave-mixing optical method and those of the graphite furnace atomizer, one can obtain both excellent spectral resolution and detection sensitivity. A preliminary concentration detection limit of 0.07 parts-per-quadrillion and a preliminary mass detection limit of 0.7 ag or 8 zmol are determined for rubidium using a compact laser diode as the excitation source.

  18. A semiconductor laser device

    Energy Technology Data Exchange (ETDEWEB)

    Takaro, K.; Naoki, T.; Satosi, K.; Yasutosi, K.

    1984-03-17

    A device is proposed which makes it possible to obtain single vertical mode emission in the absence of noise. Noise suppression is achieved by a method which determines the relationship between the donor densities in the second and third layers of an n type semiconductor laser, and the total output optical emission of layers with respect to the emission from the entire laser. The device consists of a photoresist film with a window applied to a 100 GaAs n type conductivity substrate using a standard method. Chemical etching through this window in the substrate is used to generate a slot approximately 1 micrometer in size. After the photoresist film is removed, the following layers are deposited from the liquid phase onto the substrate in the sequence indicated: a telurium doped protective layer of n type AlxGa(1-x) As; 2) an undoped active p type AlyGa(1-6) As layer and a tellurium doped upper protective n type conductivity GaAs layer.

  19. Environmental Regulation of Plant Gene Expression: An Rt-qPCR Laboratory Project for an Upper-Level Undergraduate Biochemistry or Molecular Biology Course

    Science.gov (United States)

    Eickelberg, Garrett J.; Fisher, Alison J.

    2013-01-01

    We present a novel laboratory project employing "real-time" RT-qPCR to measure the effect of environment on the expression of the "FLOWERING LOCUS C" gene, a key regulator of floral timing in "Arabidopsis thaliana" plants. The project requires four 3-hr laboratory sessions and is aimed at upper-level undergraduate…

  20. Teradiode's high brightness semiconductor lasers

    Science.gov (United States)

    Huang, Robin K.; Chann, Bien; Burgess, James; Lochman, Bryan; Zhou, Wang; Cruz, Mike; Cook, Rob; Dugmore, Dan; Shattuck, Jeff; Tayebati, Parviz

    2016-03-01

    TeraDiode is manufacturing multi-kW-class ultra-high brightness fiber-coupled direct diode lasers for industrial applications. A fiber-coupled direct diode laser with a power level of 4,680 W from a 100 μm core diameter, BPP) of 3.5 mm-mrad and is the lowest BPP multi-kW-class direct diode laser yet reported. This laser is suitable for industrial materials processing applications, including sheet metal cutting and welding. This 4-kW fiber-coupled direct diode laser has comparable brightness to that of industrial fiber lasers and CO2 lasers, and is over 10x brighter than state-of-the-art direct diode lasers. We have also demonstrated novel high peak power lasers and high brightness Mid-Infrared Lasers.

  1. Efficacy of low-level laser therapy for the treatment of burning mouth syndrome: a randomized, controlled trial

    Science.gov (United States)

    Spanemberg, Juliana Cassol; López, José López; de Figueiredo, Maria Antonia Zancanaro; Cherubini, Karen; Salum, Fernanda Gonçalves

    2015-09-01

    The aim of the present study was to assess the effect of low-level laser therapy (LLLT) in the treatment of burning mouth syndrome (BMS). A diode laser was used in 78 BMS patients who were randomly assigned into four groups: IR1W, n=20 (830 nm, 100 mW, 5 J, 176 J/cm2, 50 s, LLLT weekly sessions, 10 sessions); IR3W, n=20 (830 nm, 100 mW, 5 J, 176 J/cm2, 50 s, three LLLT weekly sessions, 9 sessions); red laser, n=19 (685 nm, 35 mW, 2 J, 72 J/cm2, 58 s, three LLLT weekly sessions, 9 sessions); and control-group (CG), n=19. Symptoms were assessed at the end of the treatment and eight weeks later; quality of life related to oral health was assessed using the Oral Health Impact Profile (OHIP-14). Statistical analysis was carried out using repeated measures analysis of variance followed by the posthoc Tukey test. There was significant reduction of the symptoms in all groups at the end of the treatment, which was maintained in the follow-up. The scores of the IR1W and IR3W laser groups differed significantly from those of the CG. There was also a decrease in the OHIP-14 scores in the four groups. The IR3W laser group scores differed significantly from those of the CG. LLLT reduces the symptoms of BMS and may be an alternative therapeutic strategy for the relief of symptoms in patients with BMS.

  2. Magnetically switched power supply system for lasers

    Science.gov (United States)

    Pacala, Thomas J. (Inventor)

    1987-01-01

    A laser power supply system is described in which separate pulses are utilized to avalanche ionize the gas within the laser and then produce a sustained discharge to cause the gas to emit light energy. A pulsed voltage source is used to charge a storage device such as a distributed capacitance. A transmission line or other suitable electrical conductor connects the storage device to the laser. A saturable inductor switch is coupled in the transmission line for containing the energy within the storage device until the voltage level across the storage device reaches a predetermined level, which level is less than that required to avalanche ionize the gas. An avalanche ionization pulse generating circuit is coupled to the laser for generating a high voltage pulse of sufficient amplitude to avalanche ionize the laser gas. Once the laser gas is avalanche ionized, the energy within the storage device is discharged through the saturable inductor switch into the laser to provide the sustained discharge. The avalanche ionization generating circuit may include a separate voltage source which is connected across the laser or may be in the form of a voltage multiplier circuit connected between the storage device and the laser.

  3. Cyclic Voltammetry Simulations with DigiSim Software: An Upper-Level Undergraduate Experiment

    Science.gov (United States)

    Messersmith, Stephania J.

    2014-01-01

    An upper-division undergraduate chemistry experiment is described which utilizes DigiSim software to simulate cyclic voltammetry (CV). Four mechanisms were studied: a reversible electron transfer with no subsequent or proceeding chemical reactions, a reversible electron transfer followed by a reversible chemical reaction, a reversible chemical…

  4. Estimation of small surface displacements in the Upper Rhine Graben area from a combined analysis of PS-InSAR, levelling and GNSS data

    NARCIS (Netherlands)

    Fuhrmann, T.; Caro Cuenca, M.; Knöpfler, A.; Leijen, F.J. van; Mayer, M.; Westerhaus, M.; Hanssen, R.F.; Heck, B.

    2015-01-01

    The intra-plate deformation of the Upper Rhine Graben (URG) located in Central Europe is investigated using geodetic measurement techniques. We present a new approach to calculate a combined velocity field from InSAR, levelling and GNSS measurements. As the expected tectonic movements in the URG

  5. Clinical Effects of Laser Acupuncture plus Chinese Cupping on the Pain and Plasma Cortisol Levels in Patients with Chronic Nonspecific Lower Back Pain: A Randomized Controlled Trial.

    Science.gov (United States)

    Lin, Mu-Lien; Wu, Jih-Huah; Lin, Chi-Wan; Su, Chuan-Tsung; Wu, Hung-Chien; Shih, Yong-Sheng; Chiu, I-Ting; Chen, Chao-Yi; Chang, Wen-Dien

    2017-01-01

    Chronic nonspecific lower back pain (LBP) is a common disease. Insufficient data is currently available to conclusively confirm the analgesic effects of laser acupuncture on LBP. This study evaluated the effectiveness of laser acupuncture plus Chinese cupping in LBP treatment. Patients with chronic nonspecific LBP were enrolled for a randomized controlled trial and assigned to the laser acupuncture group (laser acupuncture plus Chinese cupping) and control group (sham laser plus Chinese cupping). Laser acupuncture (808 nm; 40 mW; 20 Hz; 15 J/cm 2 ) and Chinese cupping were applied on the Weizhong (BL40) and Ashi acupoints for 5 consecutive days. Plasma cortisol levels were assessed before and after the 5-day treatment session. The visual analog scale (VAS) scores were recorded at baseline and throughout the 5-day treatment session. After the treatment session, the plasma cortisol levels and VAS scores decreased significantly in both groups. In the laser acupuncture group, the VAS scores decreased significantly on days 4 and 5, and an enhanced reduction in VAS scores was observed. Laser acupuncture plus Chinese cupping at the Weizhong (BL40) and Ashi acupoints effectively reduced pain and inflammation in chronic nonspecific LBP. This therapy could be a suitable option for LBP treatment in clinical settings.

  6. An assessment of racial differences in the upper limits of normal ALT levels in children and the effect of obesity on elevated values.

    Science.gov (United States)

    Kliethermes, S; Ma, M; Purtell, C; Balasubramanian, N; Gonzalez, B; Layden, T J; Cotler, S J

    2017-10-01

    Childhood obesity is a risk factor for non-alcoholic fatty liver disease and poses important public health issues for children. Racial differences in alanine aminotransferase (ALT) levels among children have not been described. This study aimed to identify racial differences in upper limit normal (ULN) ALT levels and evaluate the effect of obesity on elevated levels in children without other metabolic risk factors. National Health and Nutrition Examination Surveys and clinical data from the Loyola University Health System were used to determine ULN ALT by race and gender. Quantile regression was used to evaluate the impact of obesity on elevated ALT and to identify potential risk factors for ALT above the ULN. Upper limit normal (ULN) ALT was approximately 28.0 and 21.0-24.0 U/L for boys and girls, respectively. No significant difference in ULN ALT across race was observed. Obesity was significantly associated with elevated ALT; obese children with elevated ALT had values 10 U/L higher than normal-weight children. Racial differences in ALT levels among adults are not evident in children. Obesity, in the absence of metabolic risk factors and other causes of liver disease, is associated with elevated ALT, providing evidence against the concept of healthy obesity in children. © 2016 World Obesity Federation.

  7. Influences on target irradiation symmetry in CO2 laser-fusion experiments

    International Nuclear Information System (INIS)

    Carman, R.L.

    1981-01-01

    The existence of very steep density profiles and high upper shelf densities imply that the CO 2 laser deposits its energy spatially quite close to the ablation surface where calculations indicate that a high degree of symmetry must exist in order to achieve the necessary high compression ratios. Thus, energy transport provides only limited improvement in the ablative symmetry over that achieved in the irradiation symmetry. Current data suggests that a balance between radiation pressure and hydrodynamic pressure underestimates the density to which the CO 2 laser light penetrates for early times

  8. 980 nm diode lasers in oral and facial practice: current state of the science and art.

    Science.gov (United States)

    Desiate, Apollonia; Cantore, Stefania; Tullo, Domenica; Profeta, Giovanni; Grassi, Felice Roberto; Ballini, Andrea

    2009-11-24

    To evaluate the safety and efficacy of a 980 nm diode laser for the treatment of benign facial pigmented and vascular lesions, and in oral surgery. 20 patients were treated with a 980 nm diode laser. Oral surgery: 5 patients (5 upper and lower frenulectomy). Fluence levels were 5-15 J/cm(2); pulse lengths were 20-60 ms; spot size was 1 mm. Vascular lesions: 10 patients (5 small angiomas, 5 telangiectases). Fluences were 6-10 J/cm(2); pulse lengths were 10-50 ms; spot size was 2 mm. In all cases the areas surrounding the lesions were cooled. Pigmented lesions: 5 patients (5 keratoses). All the lesions were evaluated by dermatoscopy before the treatment. Fluence levels were 7-15 J/cm(2); pulse lengths were 20-50 ms; spot size was 1 mm. All the patients were followed at 1, 4 and 8 weeks after the procedure. Healing in oral surgery was within 10 days. The melanoses healed completely within four weeks. All the vascular lesions healed after 15 days without any residual scarring. The end results for the use of the 980 nm diode laser in oral and facial surgery appears to be justified on the grounds of efficacy and safety of the device, and good degree of acceptance by the patients, without compromising their health and function.

  9. Survey of upper extremity injuries among martial arts participants.

    Science.gov (United States)

    Diesselhorst, Matthew M; Rayan, Ghazi M; Pasque, Charles B; Peyton Holder, R

    2013-01-01

    To survey participants at various experience levels of different martial arts (MA) about upper extremity injuries sustained during training and fighting. A 21-s question survey was designed and utilised. The survey was divided into four groups (Demographics, Injury Description, Injury Mechanism, and Miscellaneous information) to gain knowledge about upper extremity injuries sustained during martial arts participation. Chi-square testing was utilised to assess for significant associations. Males comprised 81% of respondents. Involvement in multiple forms of MA was the most prevalent (38%). The hand/wrist was the most common area injured (53%), followed by the shoulder/upper arm (27%) and the forearm/elbow (19%). Joint sprains/muscle strains were the most frequent injuries reported overall (47%), followed by abrasions/bruises (26%). Dislocations of the upper extremity were reported by 47% of participants while fractures occurred in 39%. Surgeries were required for 30% of participants. Females were less likely to require surgery and more likely to have shoulder and elbow injuries. Males were more likely to have hand injuries. Participants of Karate and Tae Kwon Do were more likely to have injuries to their hands, while participants of multiple forms were more likely to sustain injuries to their shoulders/upper arms and more likely to develop chronic upper extremity symptoms. With advanced level of training the likelihood of developing chronic upper extremity symptoms increases, and multiple surgeries were required. Hand protection was associated with a lower risk of hand injuries. Martial arts can be associated with substantial upper extremity injuries that may require surgery and extended time away from participation. Injuries may result in chronic upper extremity symptoms. Hand protection is important for reducing injuries to the hand and wrist.

  10. Children acceptance of laser dental treatment

    Science.gov (United States)

    Lazea, Andreea; Todea, Carmen

    2016-03-01

    Objectives: To evaluate the dental anxiety level and the degree of acceptance of laser assisted pedodontic treatments from the children part. Also, we want to underline the advantages of laser use in pediatric dentistry, to make this technology widely used in treating dental problems of our children patients. Methods: Thirty pediatric dental patients presented in the Department of Pedodontics, University of Medicine and Pharmacy "Victor Babeş", Timişoara were evaluated using the Wong-Baker pain rating scale, wich was administered postoperatory to all patients, to assess their level of laser therapy acceptance. Results: Wong-Baker faces pain rating scale (WBFPS) has good validity and high specificity; generally it's easy for children to use, easy to compare and has good feasibility. Laser treatment has been accepted and tolerated by pediatric patients for its ability to reduce or eliminate pain. Around 70% of the total sample showed an excellent acceptance of laser dental treatment. Conclusions: Laser technology is useful and effective in many clinical situations encountered in pediatric dentistry and a good level of pacient acceptance is reported during all laser procedures on hard and soft tissues.

  11. PWR upper/lower internals shield

    Energy Technology Data Exchange (ETDEWEB)

    Homyk, W.A. [Indian Point Station, Buchanan, NY (United States)

    1995-03-01

    During refueling of a nuclear power plant, the reactor upper internals must be removed from the reactor vessel to permit transfer of the fuel. The upper internals are stored in the flooded reactor cavity. Refueling personnel working in containment at a number of nuclear stations typically receive radiation exposure from a portion of the highly contaminated upper intervals package which extends above the normal water level of the refueling pool. This same issue exists with reactor lower internals withdrawn for inservice inspection activities. One solution to this problem is to provide adequate shielding of the unimmersed portion. The use of lead sheets or blankets for shielding of the protruding components would be time consuming and require more effort for installation since the shielding mass would need to be transported to a support structure over the refueling pool. A preferable approach is to use the existing shielding mass of the refueling pool water. A method of shielding was devised which would use a vacuum pump to draw refueling pool water into an inverted canister suspended over the upper internals to provide shielding from the normally exposed components. During the Spring 1993 refueling of Indian Point 2 (IP2), a prototype shield device was demonstrated. This shield consists of a cylindrical tank open at the bottom that is suspended over the refueling pool with I-beams. The lower lip of the tank is two feet below normal pool level. After installation, the air width of the natural shielding provided by the existing pool water. This paper describes the design, development, testing and demonstration of the prototype device.

  12. Manipulating the wavelength-drift of a Tm laser for resonance enhancement in an intra-cavity pumped Ho laser.

    Science.gov (United States)

    Huang, Haizhou; Huang, Jianhong; Liu, Huagang; Li, Jinhui; Lin, Zixiong; Ge, Yan; Dai, Shutao; Deng, Jing; Lin, Wenxiong

    2018-03-05

    We demonstrate an enhancement mechanism and thermal model for intra-cavity pumped lasers, where resonance enhancement in intra-cavity pumped Ho laser was achieved by manipulating the wavelength-drift nature of the Tm laser for the first time. Optical conversion efficiency of 37.5% from an absorbed 785 nm diode laser to a Ho laser was obtained with a maximum output power of 7.51 W at 2122 nm, which is comparable to the conversion efficiency in 1.9 μm LD pumped Ho lasers. Meanwhile, more severe thermal effects in the Ho-doped gain medium than the Tm-doped one at high power operation were verified based on the built thermal model. This work benefits the design or evaluation of intra-cavity pumped lasers, and the resonance enhancement originated from the difference in reabsorption loss between stark levels at the lasing manifolds of quasi-three-level rare-earth ions has great interest to improve the existing intra-cavity pumped lasers or explore novel lasers.

  13. Effects of power densities, continuous and pulse frequencies, and number of sessions of low-level laser therapy on intact rat brain.

    Science.gov (United States)

    Ilic, Sanja; Leichliter, Sandra; Streeter, Jackson; Oron, Amir; DeTaboada, Luis; Oron, Uri

    2006-08-01

    The aim of the present study was to investigate the possible short- and long-term adverse neurological effects of low-level laser therapy (LLLT) given at different power densities, frequencies, and modalities on the intact rat brain. LLLT has been shown to modulate biological processes depending on power density, wavelength, and frequency. To date, few well-controlled safety studies on LLLT are available. One hundred and eighteen rats were used in the study. Diode laser (808 nm, wavelength) was used to deliver power densities of 7.5, 75, and 750 mW/cm2 transcranially to the brain cortex of mature rats, in either continuous wave (CW) or pulse (Pu) modes. Multiple doses of 7.5 mW/cm2 were also applied. Standard neurological examination of the rats was performed during the follow-up periods after laser irradiation. Histology was performed at light and electron microscopy levels. Both the scores from standard neurological tests and the histopathological examination indicated that there was no long-term difference between laser-treated and control groups up to 70 days post-treatment. The only rats showing an adverse neurological effect were those in the 750 mW/cm2 (about 100-fold optimal dose), CW mode group. In Pu mode, there was much less heating, and no tissue damage was noted. Long-term safety tests lasting 30 and 70 days at optimal 10x and 100x doses, as well as at multiple doses at the same power densities, indicate that the tested laser energy doses are safe under this treatment regime. Neurological deficits and histopathological damage to 750 mW/cm2 CW laser irradiation are attributed to thermal damage and not due to tissue-photon interactions.

  14. Population inversion and threshold condition for laser oscillation in optically thin and thick recombining plasmas

    International Nuclear Information System (INIS)

    Oda, Toshiatsu; Furukane, Utaro.

    1982-03-01

    Overpopulation density δn sub(ij) which is defined as difference between the population densities per unit statistical weight of the upper and lower excited levels i and j is calculated as a function of the electron density n sub(e) for various electron temperatures T sub(e) in recombining hydrogen plasmas. The calculation is made for the line pairs with the principal quantum numbers, (2, 3), (3, 4) and (4, 5). Effect of the ground level population density n sub(l) on δn sub(ij) is calculated. In this calculation the atom-atom collision and the self-absorption of the resonance lines are taken account of. The n sub(l)-dependence of δn sub(ij) remains almost constant until the self-absorption becomes significant. When n sub(l) is zero, an optimum value of n sub(e) exists for δn sub(ij). The threshold condition for laser oscillation is discussed in relation to the calculated δn sub(ij). Laser oscillation is possible for the line pair (2, 3) at an electron density and temperature higher than for the other pairs (3, 4) and (4, 5) when the self-absorption is negligible. (author)

  15. Analog phase lock between two lasers at LISA power levels

    International Nuclear Information System (INIS)

    Diekmann, Christian; Steier, Frank; Sheard, Benjamin; Heinzel, Gerhard; Danzmann, Karsten

    2009-01-01

    This paper presents the implementation of an analog optical phase-locked-loop with an offset frequency of about 20MHz between two lasers, where the detected light powers were of the order of 31 pW and 200 μW. The goal of this setup was the design and characterization of a photodiode transimpedance amplifier for application in LISA. By application of a transimpedance amplifier designed to have low noise and low power consumption, the phase noise between the two lasers was a factor of two above the shot noise limit down to 60mHz. The achievable phase sensitivity depends ultimately on the available power of the highly attenuated master laser and on the input current noise of the transimpedance amplifier of the photodetector. The limiting noise source below 60mHz was the analog phase measurement system that was used in this experiment. A digital phase measurement system that is currently under development at the AEI will be used in the near future. Its application should improve the sensitivity.

  16. Analog phase lock between two lasers at LISA power levels

    Energy Technology Data Exchange (ETDEWEB)

    Diekmann, Christian; Steier, Frank; Sheard, Benjamin; Heinzel, Gerhard; Danzmann, Karsten, E-mail: Christian.Diekmann@aei.mpg.d [Max-Planck-Institute for Gravitational Physics, Callinstr. 38, D-30167 Hannover (Germany)

    2009-03-01

    This paper presents the implementation of an analog optical phase-locked-loop with an offset frequency of about 20MHz between two lasers, where the detected light powers were of the order of 31 pW and 200 muW. The goal of this setup was the design and characterization of a photodiode transimpedance amplifier for application in LISA. By application of a transimpedance amplifier designed to have low noise and low power consumption, the phase noise between the two lasers was a factor of two above the shot noise limit down to 60mHz. The achievable phase sensitivity depends ultimately on the available power of the highly attenuated master laser and on the input current noise of the transimpedance amplifier of the photodetector. The limiting noise source below 60mHz was the analog phase measurement system that was used in this experiment. A digital phase measurement system that is currently under development at the AEI will be used in the near future. Its application should improve the sensitivity.

  17. Diode-pumped cw Nd:YAG three-level laser at 869 nm.

    Science.gov (United States)

    Lü, Yanfei; Xia, Jing; Cheng, Weibo; Chen, Jifeng; Ning, Guobin; Liang, Zuoliang

    2010-11-01

    We report for the first time (to our knowledge) a diode-pumped Nd:YAG laser emitting at 869 nm based on the (4)F(3/2)-(4)I(9/2) transition, generally used for a 946 nm emission. Power of 453 mW at 869 nm has been achieved in cw operation with a fiber-coupled laser diode emitting 35.4 W at 809 nm. Intracavity second-harmonic generation in the cw mode has also been demonstrated with power of 118 mW at 435 nm by using a BiB(3)O(6) nonlinear crystal. In our experiment, we used a LiNbO(3) crystal lens to complement the thermal lens of the laser rod, and we obtained good beam quality and high output power stability.

  18. A dye center laser pumped by emission from copper vapor and dye lasers

    Energy Technology Data Exchange (ETDEWEB)

    Loktyushin, A A; Chernyshev, A I; Soldatov, A N; Sukhanov, V B; Troitskiy, V O

    1983-01-01

    LiF:F2+ lasing is reported for the case of pumping by total emission with frequencies of 570.6 and 578.2 nanometers or by a single yellow copper vapor laser line and emission from an oxazene-17 dye laser excited by emission from a Cu laser. Lasing with a mean power level of 23 milliwatts with a maximum at 911 nanometers is obtained. The maximum efficiency was 3.4 percent with pumping of the dye centers by emission from the yellow Cu laser line. The lasing characteristics of the laser for all the types of pumping used are given.

  19. Laser surface processing with controlled nitrogen-argon concentration levels for regulated surface life time

    Science.gov (United States)

    Obeidi, M. Ahmed; McCarthy, E.; Brabazon, D.

    2018-03-01

    Laser surface modification can be used to enhance the mechanical properties of a material, such as hardness, toughness, fatigue strength, and corrosion resistance. Surface nitriding is a widely used thermochemical method of surface modification, in which nitrogen is introduced into a metal or other material at an elevated temperature within a furnace. It is used on parts where there is a need for increased wear resistance, corrosion resistance, fatigue life, and hardness. Laser nitriding is a novel method of nitriding where the surface is heated locally by a laser, either in an atmosphere of nitrogen or with a jet of nitrogen delivered to the laser heated site. It combines the benefits of laser modification with those of nitriding. Recent work on high toughness tool steel samples has shown promising results due to the increased nitrogen gas impingement onto the laser heated region. Increased surface activity and nitrogen adsorption was achieved which resulted in a deeper and harder surface compared to conventional hardening methods. In this work, the effects of the laser power, pulse repetition frequency, and overlap percentage on laser surface treatment of 316 L SST steel samples with an argon-nitrogen jet will be presented. Resulting microstructure, phase type, microhardness, and wear resistance are presented.

  20. Synthesizing and Characterizing Graphene via Raman Spectroscopy: An Upper-Level Undergraduate Experiment That Exposes Students to Raman Spectroscopy and a 2D Nanomaterial

    Science.gov (United States)

    Parobek, David; Shenoy, Ganesh; Zhou, Feng; Peng, Zhenbo; Ward, Michelle; Liu, Haitao

    2016-01-01

    In this upper-level undergraduate experiment, students utilize micro-Raman spectroscopy to characterize graphene prepared by mechanical exfoliation and chemical vapor deposition (CVD). The mechanically exfoliated samples are prepared by the students while CVD graphene can be purchased or obtained through outside sources. Owing to the intense Raman…

  1. Efficacy of low-level laser therapy in the management of pain, facial swelling, and postoperative trismus after a lower third molar extraction. A preliminary study.

    Science.gov (United States)

    López-Ramírez, Marta; Vílchez-Pérez, Miguel Angel; Gargallo-Albiol, Jordi; Arnabat-Domínguez, Josep; Gay-Escoda, Cosme

    2012-05-01

    Pain, swelling, and trismus are the most common complications after surgical removal of impacted lower third molars. The aim of this study was to evaluate the analgesic and anti-inflammatory effects of a low-level laser therapy (Laser Smile™, Biolase®, San Clemente, USA) applied to the wound appeared after the surgical removal of impacted lower third molars. A prospective, randomized, and double-blind study was undertaken in 20 healthy patients with two symmetrically impacted lower third molars. The application of a low-level laser was made randomly on one of the two sides after surgery. The experimental side received 5 J/cm(2) of energy density, a wavelength of 810 nm, and an output power of 0.5 W. On the control side, a handpiece was applied intraorally, but the laser was not activated. Evaluations of postoperative pain, trismus, and swelling were made. The sample consisted of 11 women and nine men, and mean age was 23.35 years (18-37). The pain level in the first hours after surgery was lower in the experimental side than in the placebo side, although without statistically significant differences (p = 0.258). Swelling and trismus at the 2nd and 7th postoperative days were slightly higher in the control side, although not statistically significant differences were detected (p > 0.05). The application of a low-level laser with the parameters used in this study did not show beneficial affects in reducing pain, swelling, and trismus after removal of impacted lower third molars.

  2. Excimer laser correction of hyperopia, hyperopic and mixed astigmatism: past, present, and future.

    Science.gov (United States)

    Lukenda, Adrian; Martinović, Zeljka Karaman; Kalauz, Miro

    2012-06-01

    The broad acceptance of "spot scanning" or "flying spot" excimer lasers in the last decade has enabled the domination of corneal ablative laser surgery over other refractive surgical procedures for the correction of hyperopia, hyperopic and mixed astigmatism. This review outlines the most important reasons why the ablative laser correction of hyperopia, hyperopic and mixed astigmatism for many years lagged behind that of myopia. Most of today's scanning laser systems, used in the LASIK and PRK procedures, can safely and effectively perform low, moderate and high hyperopic and hyperopic astigmatic corrections. The introduction of these laser platforms has also significantly improved the long term refractive stability of hyperopic treatments. In the future, further improvements in femtosecond and nanosecond technology, eye-tracker systems, and the development of new customized algorithms, such as the ray-tracing method, could additionally increase the upper limit for the safe and predictable corneal ablative laser correction ofhyperopia, hyperopic and mixed astigmatism.

  3. Navigated Pattern Laser System versus Single-Spot Laser System for Postoperative 360-Degree Laser Retinopexy.

    Science.gov (United States)

    Kulikov, Alexei N; Maltsev, Dmitrii S; Boiko, Ernest V

    2016-01-01

    Purpose . To compare three 360°-laser retinopexy (LRP) approaches (using navigated pattern laser system, single-spot slit-lamp (SL) laser delivery, and single-spot indirect ophthalmoscope (IO) laser delivery) in regard to procedure duration, procedural pain score, technical difficulties, and the ability to achieve surgical goals. Material and Methods . Eighty-six rhegmatogenous retinal detachment patients (86 eyes) were included in this prospective randomized study. The mean procedural time, procedural pain score (using 4-point Verbal Rating Scale), number of laser burns, and achievement of the surgical goals were compared between three groups (pattern LRP (Navilas® laser system), 36 patients; SL-LRP, 28 patients; and IO-LRP, 22 patients). Results . In the pattern LRP group, the amount of time needed for LRP and pain level were statistically significantly lower, whereas the number of applied laser burns was higher compared to those in the SL-LRP group and in the IO-LRP group. In the pattern LRP, SL-LRP, and IO-LRP groups, surgical goals were fully achieved in 28 (77.8%), 17 (60.7%), and 13 patients (59.1%), respectively ( p > 0.05). Conclusion . The navigated pattern approach allows improving the treatment time and pain in postoperative 360° LRP. Moreover, 360° pattern LRP is at least as effective in achieving the surgical goal as the conventional (slit-lamp or indirect ophthalmoscope) approaches with a single-spot laser.

  4. Low-level laser irradiation promotes the proliferation and maturation of keratinocytes during epithelial wound repair

    Science.gov (United States)

    Sperandio, Felipe F.; Simões, Alyne; Corrêa, Luciana; Aranha, Ana Cecília C.; Giudice, Fernanda S.; Hamblin, Michael R.; Sousa, Suzana C.O.M.

    2015-01-01

    Low-level laser therapy (LLLT) has been extensively employed to improve epithelial wound healing, though the exact response of epithelium maturation and stratification after LLLT is unknown. Thus, this study aimed to assess the in vitro growth and differentiation of keratinocytes (KCs) and in vivo wound healing response when treated with LLLT. Human KCs (HaCaT cells) showed an enhanced proliferation with all the employed laser energy densities (3, 6 and 12 J/cm2, 660nm, 100mW), together with an increased expression of Cyclin D1. Moreover, the immunoexpression of proteins related to epithelial proliferation and maturation (p63, CK10, CK14) all indicated a faster maturation of the migrating KCs in the LLLT-treated wounds. In that way, an improved epithelial healing was promoted by LLLT with the employed parameters; this improvement was confirmed by changes in the expression of several proteins related to epithelial proliferation and maturation. PMID:25411997

  5. Watt-level passively Q-switched double-cladding fiber laser based on graphene oxide saturable absorber.

    Science.gov (United States)

    Yu, Zhenhua; Song, Yanrong; Dong, Xinzheng; Li, Yanlin; Tian, Jinrong; Wang, Yonggang

    2013-10-10

    A watt-level passively Q-switched ytterbium-doped double-cladding fiber laser with a graphene oxide (GO) absorber was demonstrated. The structure of the GO saturable absorber mirror (GO-SAM) was of the sandwich type. A maximum output power of 1.8 W was obtained around a wavelength of 1044 nm. To the best of our knowledge, this is the highest output power in Q-switched fiber lasers based on a GO saturable absorber. The pure GO was protected from the oxygen in the air so that the damage threshold of the GO-SAM was effectively raised. The gain fiber was a D-shaped ytterbium-doped double-cladding fiber. The pulse repetition rates were tuned from 120 to 215 kHz with pump powers from 3.89 to 7.8 W. The maximum pulse energy was 8.37 μJ at a pulse width of 1.7 μs.

  6. Influence of laser radiation on structure and properties of steels and alloys

    International Nuclear Information System (INIS)

    Tarasova, T; Popova, E

    2013-01-01

    In present study, and laser alloying of different steels and laser cladding of Ti and SiC powders mixtures was carried out, and microstructure, as well as microhardness profile and wear properties were examined. Research of the influence of lasers alloying modes on the elastic and plastic characteristics of the surface was conducted. As a result of chemical reactions in the cladded layer, a new phase (TiC) was synthesized during cladding process. The results showed that, in the clad layer, TiC was solidified to form dendrites in the clad zone. Produced coatings have high microhardness values in the upper and middle clad areas, about two time higher than clad matrix microhardness.

  7. Laser cleaning of sulfide scale on compressor impeller blade

    International Nuclear Information System (INIS)

    Tang, Q.H.; Zhou, D.; Wang, Y.L.; Liu, G.F.

    2015-01-01

    Highlights: • The effects of sulfide layers and fluence values on the mechanism of laser cleaning were experimentally established. • The specimen surface with sulfide scale becomes slightly smoother than that before laser cleaning. • The mechanism of laser cleaning the sulfide scale of stainless steel is spallation without oxidization. • It would avoid chemical waste and dust pollution using a fiber laser instead of using nitric acids or sandblasting. - Abstract: Sulfide scale on the surface of a compressor impeller blade can considerably reduce the impeller performance and its service life. To prepare for subsequent remanufacturing, such as plasma spraying, it needs to be removed completely. In the corrosion process on an FV(520)B stainless steel, sulfide scale is divided into two layers because of different outward diffusion rates of Cr, Ni and Fe. In this paper, the cleaning threshold values of the upper and inner layers and the damage threshold value of the substrate were investigated using a pulsed fiber laser. To obtain experimental evidence, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) and 3D surface profilometry were employed to investigate the two kinds of sulfide layers on specimens before, during, and after laser cleaning.

  8. Effects of optical feedback in a birefringence-Zeeman dual frequency laser at high optical feedback levels

    International Nuclear Information System (INIS)

    Mao Wei; Zhang Shulian

    2007-01-01

    Optical feedback effects are studied in a birefringence-Zeeman dual frequency laser at high optical feedback levels. The intensity modulation features of the two orthogonally polarized lights are investigated in both isotropic optical feedback (IOF) and polarized optical feedback (POF). In IOF, the intensities of both beams are modulated simultaneously, and four zones, i.e., the e-light zone, the o-light and e-light zone, the o-light zone, and the no-light zone, are formed in a period corresponding to a half laser wavelength displacement of the feedback mirror. In POF, the two orthogonally polarized lights will oscillate alternately. Strong mode competition can be observed, and it affects the phase difference between the two beams greatly. The theoretical analysis is presented, which is in good agreement with the experimental results. The potential use of the experimental results is also discussed

  9. Upper-level enhancement of microphysical processes in extratropical cyclones observed during OLYMPEX

    Science.gov (United States)

    Rowe, A.; McMurdie, L. A.; Houze, R.; Zagrodnik, J. P.; Schuldt, T.; Chaplin, M.

    2017-12-01

    Data collected during the Olympic Mountains Experiment (OLYMPEX) of fall 2015-winter 2016 offer a unique opportunity to document enhancement of precipitation on the windward side of a mountain range as mid-latitude cyclones encountered the complex terrain of the Olympic Mountains. During the campaign, extensive instrumentation was deployed, including ground-based dual-polarization Doppler radars on the windward and leeward sides of the mountains and research aircraft providing in situ microphysical measurements and triple-frequency radar data over the ground-based sites and highest elevations. These datasets provide unprecedented detail on microphysical and dynamical processes associated with precipitation enhancement. Previous studies of precipitation enhancement over mountains have focused on surface rainfall amounts. However, the airflow over the terrain affects precipitation throughout the vertical columns of the atmosphere passing over the mountains. The OLYMPEX data were collected in a way that allows the mechanisms leading to enhancement to be examined at all levels. In particular, NASA's S-band and the NSF/CSWR DOW6 X-band dual-polarization radars provided high-resolution vertical cross sections in sectors upwind and over the mountains. The degree of upper-level enhancement seen in these radar data was most pronounced when the integrated vapor transport was strong, stability was moist neutral, and melting levels were relatively high. These conditions were often found within the warm sectors of the mid-latitude cyclones observed in OLYMPEX. Within widespread stratiform echo, radar data revealed layers of enhanced differential reflectivity aloft in addition to the enhanced reflectivity. In situ microphysical probe data from the University of North Dakota Citation aircraft were obtained in the context of these ground-based radar observations, which along with observations from the APR3 radar aboard the DC8 research aircraft, provide a unique dataset for

  10. Upper limit set for level of lightning activity on Titan

    Science.gov (United States)

    Desch, M. D.; Kaiser, M. L.

    1990-01-01

    Because optically thick cloud and haze layers prevent lightning detection at optical wavelength on Titan, a search was conducted for lightning-radiated signals (spherics) at radio wavelengths using the planetary radioastronomy instrument aboard Voyager 1. Given the maximum ionosphere density of about 3000/cu cm, lightning spherics should be detectable above an observing frequency of 500 kHz. Since no evidence for spherics is found, an upper limit to the total energy per flash in Titan lightning of about 10 to the 6th J, or about 1000 times weaker than that of typical terrestrial lightning, is inferred.

  11. Vacuum thermalization of high intensity laser beams and the uncertainty principle

    International Nuclear Information System (INIS)

    Gupta, R.P.; Bhakar, B.S.; Panarella, E.

    1983-01-01

    This chapter phenomenologically calculates the cross section for photon-photon scattering in high intensity laser beams. The consequence of the Heisenberg uncertainty principle must be taken account in any photon-photon scattering calculation when many photons are present within the uncertainty volume. An exact determination of the number of scattering centers present in the scattering region is precluded when high intensity laser beams are involved in the scattering. Predictions are presented which suggest an upper limit to which the coherent photon densities can be increased either during amplification or focusing before scattering becomes predominant. The results of multiphoton ionization of gases, and laser induced CTR plasmas of the future, may be significantly affected due to the enhancement of the photon scattering investigated

  12. The effect of low-level laser therapy on trismus and facial swelling following surgical extraction of a lower third molar.

    Science.gov (United States)

    Aras, Mutan Hamdi; Güngörmüş, Metin

    2009-02-01

    The purpose of this study was to evaluate the effect of low-level laser therapy (LLLT) on postoperative trismus and edema after the removal of mandibular third molars. Thirty-two patients who were to undergo surgical removal of lower third molars were studied. Patients were randomly allocated to two groups, LLLT and placebo. Patients in the LLLT group received 12 J (4 J/cm(2)) low-level laser irradiation to the operative side intraorally 1 cm from the target tissue, and to the masseter muscle extraorally immediately after surgery. In the placebo group the handpiece was inserted into the operative side intraorally and was applied to the masseter muscle extraorally each for 1 min, but laser power was not activated. Inter-incisal opening and facial swelling were evaluated on postoperative days 2 and 7. Student's t-test used to analyze the data. It was determined that the trismus and the swelling in LLLT group were significantly less than in the placebo group on postoperative days 2 and 7. Within the limitations of this study it can be concluded that LLLT can be beneficial for the reduction of postoperative trismus and swelling after third molar surgery.

  13. Bactericidal effect of Nd:YAG laser irradiation in endodontics

    Science.gov (United States)

    Aun, Carlos E.; Barberini, Alexandre F.; Camargo, Selma C. C.; Silva Kfouri, Luciana; Lorenzetti Simionato, Maria R.

    1999-05-01

    The success of endodontic therapy is based on the elimination of bacterial colonization from the endodontic system and periapical tissues. Recent studies have been showing the bactericidal effect of laser in root canal treatment. The propose of the study is to evaluate the effect of Nd:YAG laser irradiation in contaminated root canal treatment. The propose of the study is to evaluate the effect of Nd:YAG laser irradiation in contaminated root canals from upper central incisor. For the experiment 12 teeth were selected, respect at the apical third, sterilized, and 10 μm Streptococcus sanguis liquid culture were inoculated in the root canals. The laser test groups were irradiated with Nd:YAG laser at standard setting of 15Hz, 100mj and 1,5 W for 10, 20 and 30 seconds each in slow helicoidal movements from the apex to the top using a 300 micrometers fiber. After the procedure the specimens were placed in Tryptic Soy Agar, the number of colony forming units was evaluated. The experiment showed a significant reduction on viability of Streptococcus sanguis at the respective time of 20 and 30 seconds.

  14. Effects of Low-Level Laser Irradiation on the Pathogenicity of Candida albicans: In Vitro and in Vivo Study

    NARCIS (Netherlands)

    Seyedmousavi Tasieh, S.; Hashemi, S.J.; Rezaie, S.; Fateh, M.; Djavid, G.E.; Zibafar, E.; Morsali, F.; Zand, N.; Alinaghizadeh, M.; Ataie-Fashtami, L.

    2014-01-01

    Abstract Objective: The purpose of this study was to evaluate the effects of low-level laser irradiation (LLLI) on the in vitro growth characteristics and in vivo pathogenicity of Candida albicans in a murine model in the absence of a photosensitizer. Background data: C. albicans is an opportunistic

  15. Upper-Level Mediterranean Oscillation index and seasonal variability of rainfall and temperature

    Science.gov (United States)

    Redolat, Dario; Monjo, Robert; Lopez-Bustins, Joan A.; Martin-Vide, Javier

    2018-02-01

    The need for early seasonal forecasts stimulates continuous research in climate teleconnections. The large variability of the Mediterranean climate presents a greater difficulty in predicting climate anomalies. This article reviews teleconnection indices commonly used for the Mediterranean basin and explores possible extensions of one of them, the Mediterranean Oscillation index (MOi). In particular, the anomalies of the geopotential height field at 500 hPa are analyzed using segmentation of the Mediterranean basin in seven spatial windows: three at eastern and four at western. That is, different versions of an Upper-Level Mediterranean Oscillation index (ULMOi) were calculated, and monthly and annual variability of precipitation and temperature were analyzed for 53 observatories from 1951 to 2015. Best versions were selected according to the Pearson correlation, its related p value, and two measures of standardized error. The combination of the Balearic Sea and Libya/Egypt windows was the best for precipitation and temperature, respectively. The ULMOi showed the highest predictive ability in combination with the Atlantic Multidecadal Oscillation index (AMOi) for the annual temperature throughout the Mediterranean basin. The best model built from the indices presented a final mean error between 15 and 25% in annual precipitation for most of the studied area.

  16. Evaluation of upper-shelf toughness requirements for reactor pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Gamble, R.M.; Zahoor, A. (NOVETECH Corp., Rockville, MD (USA)); Hiser, A. (Materials Engineering Associates, Inc., Lanham, MD (USA)); Ernst, H.A.; Pollitz, E.T. (Georgia Inst. of Tech., Atlanta, GA (USA))

    1990-04-01

    This work assesses and applies the criteria recommended by the ASME Subgroup on Evaluation Standards for the evaluation of reactor pressure vessel beltline materials having upper shelf Charpy energies less than 50 ft-lbs. The assessment included comparison of the upper shelf energies required by the criteria recommended for Service Level A and B conditions and criteria proposed for evaluation of postulated Service Level C and D events. The criteria recommended for Service Level A and B conditions was used to evaluate Linde 80 weld material. 9 refs., 4 figs.

  17. Evaluation of upper-shelf toughness requirements for reactor pressure vessels

    International Nuclear Information System (INIS)

    Gamble, R.M.; Zahoor, A.; Hiser, A.; Ernst, H.A.; Pollitz, E.T.

    1990-04-01

    This work assesses and applies the criteria recommended by the ASME Subgroup on Evaluation Standards for the evaluation of reactor pressure vessel beltline materials having upper shelf Charpy energies less than 50 ft-lbs. The assessment included comparison of the upper shelf energies required by the criteria recommended for Service Level A and B conditions and criteria proposed for evaluation of postulated Service Level C and D events. The criteria recommended for Service Level A and B conditions was used to evaluate Linde 80 weld material. 9 refs., 4 figs

  18. Upper Elementary Teachers' Self-Efficacy and Spelling Instruction: A Qualitative Study

    Science.gov (United States)

    Fernandes, Brian E.

    2017-01-01

    A great deal of research has been conducted regarding spelling instruction at the early childhood and lower elementary levels, but not at the upper elementary level. This qualitative study explored the perceptions and experiences of upper elementary teachers to gain a better understanding of how they instruct spelling and their related…

  19. Clinical Effects of Laser Acupuncture plus Chinese Cupping on the Pain and Plasma Cortisol Levels in Patients with Chronic Nonspecific Lower Back Pain: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mu-Lien Lin

    2017-01-01

    Full Text Available Objectives. Chronic nonspecific lower back pain (LBP is a common disease. Insufficient data is currently available to conclusively confirm the analgesic effects of laser acupuncture on LBP. This study evaluated the effectiveness of laser acupuncture plus Chinese cupping in LBP treatment. Methods. Patients with chronic nonspecific LBP were enrolled for a randomized controlled trial and assigned to the laser acupuncture group (laser acupuncture plus Chinese cupping and control group (sham laser plus Chinese cupping. Laser acupuncture (808 nm; 40 mW; 20 Hz; 15 J/cm2 and Chinese cupping were applied on the Weizhong (BL40 and Ashi acupoints for 5 consecutive days. Plasma cortisol levels were assessed before and after the 5-day treatment session. The visual analog scale (VAS scores were recorded at baseline and throughout the 5-day treatment session. Results. After the treatment session, the plasma cortisol levels and VAS scores decreased significantly in both groups. In the laser acupuncture group, the VAS scores decreased significantly on days 4 and 5, and an enhanced reduction in VAS scores was observed. Conclusion. Laser acupuncture plus Chinese cupping at the Weizhong (BL40 and Ashi acupoints effectively reduced pain and inflammation in chronic nonspecific LBP. This therapy could be a suitable option for LBP treatment in clinical settings.

  20. Risks induced by laser radiation; Risques induits par le rayonnement laser

    Energy Technology Data Exchange (ETDEWEB)

    Courant, D [CEA Fontenay-aux-Roses, 92 (France). Dept. de Radiobiologie et de Radiopathologie

    2001-07-01

    The use of lasers is often dangerous because of the emitted power, the wave length, the conduction system(optical fiber, wave guide, mirrors) and the use conditions. The safety notion involves the precise knowledge of materials, the biological effects in function of laser emission parameters, the knowledge of protection standards, the observance of use rules and the personnel training. This chapter treats the risks induced by the beam. It gives the different biological effects induced by the laser beam, at the eye and skin levels that are at the origin of exposure limits and the lasers classification recommended by the protection standards. (N.C.)

  1. Multiweek cell culture project for use in upper-level biology laboratories.

    Science.gov (United States)

    Marion, Rebecca E; Gardner, Grant E; Parks, Lisa D

    2012-06-01

    This article describes a laboratory protocol for a multiweek project piloted in a new upper-level biology laboratory (BIO 426) using cell culture techniques. Human embryonic kidney-293 cells were used, and several culture media and supplements were identified for students to design their own experiments. Treatments included amino acids, EGF, caffeine, epinephrine, heavy metals, and FBS. Students researched primary literature to determine their experimental variables, made their own solutions, and treated their cells over a period of 2 wk. Before this, a sterile technique laboratory was developed to teach students how to work with the cells and minimize contamination. Students designed their experiments, mixed their solutions, seeded their cells, and treated them with their control and experimental media. Students had the choice of manipulating a number of variables, including incubation times, exposure to treatment media, and temperature. At the end of the experiment, students observed the effects of their treatment, harvested and dyed their cells, counted relative cell numbers in control and treatment flasks, and determined the ratio of living to dead cells using a hemocytometer. At the conclusion of the experiment, students presented their findings in a poster presentation. This laboratory can be expanded or adapted to include additional cell lines and treatments. The ability to design and implement their own experiments has been shown to increase student engagement in the biology-related laboratory activities as well as develop the critical thinking skills needed for independent research.

  2. Clinical study on the removal of gingival melanin pigmentation: comparison between Nd:YAG laser ablation and mechanical abrasion

    International Nuclear Information System (INIS)

    Lopes, Luis Mario de Melo

    2002-01-01

    Melanin pigmentation occurs as a result of excessive deposition of melanin, produced by the melanocytes present in the basal layer of the epithelium. This study compares clinical parameters such as inflammation and/or hemorrhage, healing process and re-pigmentation, caused by the Nd:YAG laser ablation and the mechanical abrasion of the melanin, by means of photographic images, taken during the first 30 days after the treatment. The patients comfort was monitored during the first ten days after the treatment using the method of the Visual Analog Scale to measure the pain. Six patients with gingival melanin pigmentation were selected. The left upper gingival quadrant was treated with the Nd:YAG laser using 125 mJ per pulse and 20 Hz, the right upper gingival quadrant received mechanical abrasion and the lower quadrants served for control. Both techniques did not result in inflammation and/or hemorrhage. The healing process was slower with the laser. Using mechanical abrasion, ali patients showed remaining pigmentation or re-pigmentation of varying intensity after a period of 30 days. With the laser 50 % of the patients did not show any re-pigmentation after this period. The pain analysis showed that the pain sensed 24 hours after the treatment with the laser is higher than using mechanical abrasion. (author)

  3. Possibility of increasing the efficiency of laser-induced tattoo removal by optical skin clearing

    Science.gov (United States)

    Genina, E. A.; Bashkatov, A. N.; Tuchin, V. V.; Altshuler, G. B.; Yaroslavskii, I. V.

    2008-06-01

    The possibility of selective laser photothermolysis improvement for the removal of tattoo pigments due to the optical clearing of human skin is investigated. It is shown experimentally that the optical skin clearing increases the tattoo image contrast. Computer Monte Carlo simulations show that by decreasing the laser beam scattering in upper skin layers, it is possible to reduce the radiation power required for tattoo removal by 30%—40% and, therefore, to increase the the photothermolysis efficiency.

  4. Clinical and Histological Evaluations of Enlarged Facial Skin Pores After Low Energy Level Treatments With Fractional Carbon Dioxide Laser in Korean Patients.

    Science.gov (United States)

    Kwon, Hyuck Hoon; Choi, Sun Chul; Lee, Won-Yong; Jung, Jae Yoon; Park, Gyeong-Hun

    2018-03-01

    Enlarged facial pores can be an early manifestation of skin aging and they are a common aesthetic concern for Asians. However, studies of improving the appearance of enlarged pores have been limited. The authors aimed to study the application of CO2 fractional laser treatment in patients with enlarged facial pores. A total of 32 patients with dilated facial pores completed 3 consecutive sessions of low energy level treatments with a fractional CO2 laser at 4-week intervals. Image analysis was performed to calculate the number of enlarged pores before each treatment session and 12 weeks after the final treatment. After application of laser treatments, there was a significant decrease in the number of enlarged pores. The mean number of enlarged pores was decreased by 28.8% after the second session and by 54.5% at post-treatment evaluation. Post-treatment side effects were mild and transitory. Histological and immunohistochemical analyses demonstrated clear increases in the number of collagen fibers and the expression of transforming growth factor-β1. The short-term results showed that treatment with low energy level CO2 fractional laser therapy could be a safe and effective option for patients with Fitzpatrick skin Types III and IV who are concerned with enlarged pores.

  5. Kinetic model of a Ne-H2 Penning Recombination Laser operating in the hollow cathode discharge

    International Nuclear Information System (INIS)

    Pramatarov, P.M.; Stefanova, M.S.; Petrov, G.M.

    1995-01-01

    The Penning Recombination Laser (PRL) requires the presence of both a recombination plasma populating the upper laser level (ULL) and a gas component efficiently depopulating the lower laser level (LLL) by Penning reactions. Such requirements are met in the negative glow plasma of a pulsed high voltage Ne-H 2 discharge with a helical hollow cathode. High rates of ionizations followed by recombinations are reached due to the beam component of non-Maxwellian electrons of 1-2 keV energy present in the tail of the electron energy distribution function. The H 2 , on the one hand plays the role of Penning component and on the other hand effectively cools the electrons by rotational and vibrational levels excitation. The latter contributes to the effectiveness of the recombination processes. A kinetic model of the physical processes determining the inversion population on the NeI(2p 1 -1s 2 ) transition (the 585.3 nm line) in a Ne-H 2 PRL operating in a high voltage hollow cathode discharge at intermediate pressures is proposed. About 60 plasma-chemical reactions are considered in the model. These include: two-electron recombination of Ne + ; dissociative recombination of Ne 2 + , NeH + and H 2 + ; ion-ion recombination of Ne + and H - ; Ne and H 2 direct ionization by fast electrons; Ne stepwise ionization; Penning ionization; Ne excitation by fast electrons; Ne stepwise excitation and de-excitation; radiative transitions; electron mixing between Ne excited states; H 2 rotational and vibrational levels excitation; H 2 dissociative attachment; elastic electron collisions with H 2 and Ne. The rate constants for the reactions are either taken from the literature or calculated in this work

  6. Low-level laser therapy effects on pain perception related to the use of orthodontic elastomeric separators

    Directory of Open Access Journals (Sweden)

    Rachel D'Aurea Furquim

    2015-06-01

    Full Text Available INTRODUCTION: Some patients refer to pre-banding orthodontic separation as a painful orthodontic procedure. Low-level laser therapy (LLLT has been reported to have local analgesic effect. OBJECTIVE: The aim of this single-blind study was to investigate the perception of pain caused by orthodontic elastomeric separators with and without a single LLLT application (6J. METHODS: The sample comprised 79 individuals aged between 13 and 34 years old at orthodontic treatment onset. Elastomeric separators were placed in first maxillary molars at mesial and distal surfaces and kept in place for three days. The volunteers scored pain intensity on a visual analogue scale (VAS after 6 and 12 hours, and after the first, second and third days. One third of patients received laser applications, whereas another third received placebo applications and the remaining ones were controls. Applications were performed in a split-mouth design. Thus, three groups (laser, placebo and control were assessed. RESULTS: No differences were found among groups considering pain perception in all periods observed. CONCLUSION: The use of a single-dose of LLLT did not cause significant reduction in orthodontic pain perception. Overall pain perception due to orthodontic separator placement varied widely and was usually mild.

  7. Low-level laser irradiation protects the chick embryo chorioallantoic membrane from UV cytotoxicity

    Directory of Open Access Journals (Sweden)

    Hammami Amira

    2018-01-01

    Full Text Available Low-level laser therapy or photobiomodulation is the medical use of a very low intensity light in the red to near infrared (wavelengths in the range of 630-940 nm. The present work was conducted to explore the effects of both UV and low-level laser irradiation (LLLI on microcirculation using the in vivo model of the chick embryo chorioallantoic membrane (CAM. The effects were assessed by measuring lipid peroxidation and antioxidant enzyme activity. Cell cytotoxicity, survival and intracellular reactive oxygen species (ROS of the CAM were also evaluated. We found that UV irradiation induced alterations of the vessels, leading to bleeding and extravasation. This effect was intensified after 60 min of exposure to UV irradiation, leading to marked edema. UVA irradiation increased cell cytotoxicity as assessed by lactate dehydrogenase (LDH release (56.23% of control and reduced cell viability as assessed by decreased fluorescein diacetate (FDA fluorescence (56.23% of control. Pretreatment with LLLI prior to UV exposure protected the CAM tissue from UV-mediated cell death. This protective effect was supported by the observation of significantly inhibited lipid peroxidation (from 0.3±0.004 for UV, to 0.177±0.012 after LLLI pretreatment, ROS and O2 -production, as indicated by respective dihydrorhodamine (DHR and dihydroethidium (DHE intensities (from 132.78% of control for UVA, to 95.90% of control for L-UV (DHR, and from 127.34% of control for UVA, to 82.03% of control for L-UV (DHE, and by preventing the increase in oxidative activities. LLLI efficiently protected CAM cells from UV-induced oxidative stress and appeared as a safe protective pretreatment against UV irradiation.

  8. Growth, spectroscopy and laser operation of Ho:KY(WO{sub 4}){sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Jambunathan, V. [Física i Cristallografia de Materials i Nanomaterials (FiCMA-FiCNA), Universitat Rovira i Virgili (URV), Campus Sescelades, c/ Marcellí Domingo, s/n. E-43007 Tarragona (Spain); HiLASE Centre, Institute of Physics ASCR, Za Radnicí 828, 25241 Dolní Břežany (Czech Republic); Mateos, X., E-mail: xavier.mateos@urv.cat [Física i Cristallografia de Materials i Nanomaterials (FiCMA-FiCNA), Universitat Rovira i Virgili (URV), Campus Sescelades, c/ Marcellí Domingo, s/n. E-43007 Tarragona (Spain); Max Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, 2A Max-Born-Str., D-12489 Berlin (Germany); Loiko, P.A. [Física i Cristallografia de Materials i Nanomaterials (FiCMA-FiCNA), Universitat Rovira i Virgili (URV), Campus Sescelades, c/ Marcellí Domingo, s/n. E-43007 Tarragona (Spain); Center for Optical Materials and Technologies, Belarusian National Technical University, 65/17 Nezavisimosti Ave., 220013 Minsk (Belarus); Serres, J.M. [Física i Cristallografia de Materials i Nanomaterials (FiCMA-FiCNA), Universitat Rovira i Virgili (URV), Campus Sescelades, c/ Marcellí Domingo, s/n. E-43007 Tarragona (Spain); Griebner, U.; Petrov, V. [Max Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, 2A Max-Born-Str., D-12489 Berlin (Germany); Yumashev, K.V. [Center for Optical Materials and Technologies, Belarusian National Technical University, 65/17 Nezavisimosti Ave., 220013 Minsk (Belarus); and others

    2016-11-15

    Monoclinic Ho:KY(WO{sub 4}){sub 2} crystals doped with up to 7.5 at.% Ho are grown by the Top Seeded Solution Growth-Slow Cooling method. The evolution of their unit cell parameters in dependence on the Ho doping and temperature is studied. The polarized low-temperature (6 K) optical absorption of the Ho{sup 3+} ion is investigated in detail to determine the energy of the Stark sub-levels. Room-temperature absorption, stimulated-emission and gain cross-section spectra of Ho:KY(WO{sub 4}){sub 2} crystals are derived for polarizations parallel to the principal optical axes, E||N{sub p}, N{sub m} and N{sub g}. The maximum absorption cross-section for the {sup 5}I{sub 8}→{sup 5}I{sub 7} transition is 1.60×10{sup −20} cm{sup 2} at 1961.0 nm and the maximum stimulated-emission cross-section for the {sup 5}I{sub 7}→{sup 5}I{sub 8} transition is 2.65×10{sup −20} cm{sup 2} at 2056.3 nm (for E||N{sub m}). The radiative lifetime of the upper laser level of the Ho{sup 3+} ion ({sup 5}I{sub 7}) amounts to 4.8 ms. Continuous-wave Ho{sup 3+} laser operation is achieved under in-band pumping by a Tm laser at 1946 nm. In the microchip configuration, the maximum output power reached 205 mW at 2105 nm with a slope efficiency as high as 85%.

  9. Characterization of particle deformation during compression measured by confocal laser scanning microscopy.

    Science.gov (United States)

    Guo, H X; Heinämäki, J; Yliruusi, J

    1999-09-20

    Direct compression of riboflavin sodium phosphate tablets was studied by confocal laser scanning microscopy (CLSM). The technique is non-invasive and generates three-dimensional (3D) images. Tablets of 1% riboflavin sodium phosphate with two grades of microcrystalline cellulose (MCC) were individually compressed at compression forces of 1.0 and 26.8 kN. The behaviour and deformation of drug particles on the upper and lower surfaces of the tablets were studied under compression forces. Even at the lower compression force, distinct recrystallized areas in the riboflavin sodium phosphate particles were observed in both Avicel PH-101 and Avicel PH-102 tablets. At the higher compression force, the recrystallization of riboflavin sodium phosphate was more extensive on the upper surface of the Avicel PH-102 tablet than the Avicel PH-101 tablet. The plastic deformation properties of both MCC grades reduced the fragmentation of riboflavin sodium phosphate particles. When compressed with MCC, riboflavin sodium phosphate behaved as a plastic material. The riboflavin sodium phosphate particles were more tightly bound on the upper surface of the tablet than on the lower surface, and this could also be clearly distinguished by CLSM. Drug deformation could not be visualized by other techniques. Confocal laser scanning microscopy provides valuable information on the internal mechanisms of direct compression of tablets.

  10. The Effect of Low Level Laser Therapy on Some Plasma Ions Concentration

    Directory of Open Access Journals (Sweden)

    Nadia H. Sahib

    2017-12-01

    Full Text Available Low level laser therapy (LLLT has variousapplications in clinical pathology.It has been found to be efficient in acceleration of wound healing, enhanced remodeling and bone repair, regeneration of neural cells following injury, pain attenuation, endorphin release stimulation and modulation of immune system. The possible intracellular sequence of events after treatment with LLLT, include induction of oxidative phosphorylation with increased enzymatic activity, increased expression of certain cytosolic enzymes and enhanced activity of intracellular organelles. A broad range of eukaryotic proteins require posttranslational modifications such as phosphorylation, glycosylation, or signal peptide cleavage to display full functional activity. Eukaryotic cell-free expression systems provide the possibility to synthesize eukaryotic proteins with posttranslational modifications and are especially useful forexpression and analysis of human proteins with native structure and function.The stimulated mechanism involves protein- to-protein interaction, where two or more proteins bind together to facilitate molecular processes, including modification of proteins by members of small ubiquitin- related modifier proteins (SUMOand also protein phosphorylation and tyrosination. The consequence of laser application in treatment, can be seen as influencing the transmission of intracellular signals via an integrated and rapid modulation of ion channels, achieved through both direct action on photo-acceptors (such as cytochrome c-oxidase and through indirect modulation via enzymes,including tyrosine hydroxylase (TH, tyrosine kinases and tyrosine kinasereceptors. This exogenous action then facilitates an existing photonic biomodulation mechanism with the body, and initiates ion channel modulation both in the periphery and the central nervous system (CNS. Evidence indicates that the ion channel modulation functions predominately through the potassium channels, including

  11. Laser experimental system as teaching aid for demonstrating basic phenomena of laser feedback

    International Nuclear Information System (INIS)

    Xu, Ling; Zhao, Shijie; Zhang, Shulian

    2015-01-01

    An experimental laser teaching system is developed to demonstrate laser feedback phenomena, which bring great harm to optical communication and benefits to precision measurement. The system consists of an orthogonally polarized He-Ne laser, a feedback mirror which reflects the laser output light into the laser cavity, and an optical attenuator which changes the intensity of the feedback light. As the feedback mirror is driven by a piezoelectric ceramic, the attenuator is adjusted and the feedback mirror is tilted, the system can demonstrate many basic laser feedback phenomena, including weak, moderate and strong optical feedback, multiple feedback and polarization flipping. Demonstrations of these phenomena can give students a better understanding about the intensity and polarization of lasers. The system is well designed and assembled, simple to operate, and provides a valuable teaching aid at an undergraduate level. (paper)

  12. Peri-implant osseointegration after low-level laser therapy: micro-computed tomography and resonance frequency analysis in an animal model.

    Science.gov (United States)

    Mayer, Luciano; Gomes, Fernando Vacilotto; de Oliveira, Marília Gerhardt; de Moraes, João Feliz Duarte; Carlsson, Lennart

    2016-12-01

    The purpose of the present study is to evaluate the effects of low-level laser therapy on the osseointegration process by comparing resonance frequency analysis measurements performed at implant placement and after 30 days and micro-computed tomography images in irradiated vs nonirradiated rabbits. Fourteen male New Zealand rabbits were randomly divided into two groups of seven animals each, one control group (nonirradiated animals) and one experimental group that received low-level laser therapy (Thera Lase®, aluminum-gallium-arsenide laser diode, 10 J per spot, two spots per session, seven sessions, 830 nm, 50 mW, CW, Ø 0.0028 cm 2 ). The mandibular left incisor was surgically extracted in all animals, and one osseointegrated implant was placed immediately afterward (3.25ø × 11.5 mm; NanoTite, BIOMET 3i). Resonance frequency analysis was performed with the Osstell® device at implant placement and at 30 days (immediately before euthanasia). Micro-computed tomography analyses were then conducted using a high-resolution scanner (SkyScan 1172 X-ray Micro-CT) to evaluate the amount of newly formed bone around the implants. Irradiated animals showed significantly higher implant stability quotients at 30 days (64.286 ± 1.596; 95 % confidence interval (CI) 60.808-67.764) than controls (56.357 ± 1.596; 95 %CI 52.879-59.835) (P = .000). The percentage of newly formed bone around the implants was also significantly higher in irradiated animals (75.523 ± 8.510; 95 %CI 61.893-89.155) than in controls (55.012 ± 19.840; 95 %CI 41.380-68.643) (P = .027). Laser therapy, based on the irradiation protocol used in this study, was able to provide greater implant stability and increase the volume of peri-implant newly formed bone, indicating that laser irradiation effected an improvement in the osseointegration process.

  13. Room temperature negative differential resistance in terahertz quantum cascade laser structures

    Energy Technology Data Exchange (ETDEWEB)

    Albo, Asaf, E-mail: asafalbo@gmail.com; Hu, Qing [Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Reno, John L. [Center for Integrated Nanotechnologies, Sandia National Laboratories, MS 1303, Albuquerque, New Mexico 87185-1303 (United States)

    2016-08-22

    The mechanisms that limit the temperature performance of GaAs/Al{sub 0.15}GaAs-based terahertz quantum cascade lasers (THz-QCLs) have been identified as thermally activated LO-phonon scattering and leakage of charge carriers into the continuum. Consequently, the combination of highly diagonal optical transition and higher barriers should significantly reduce the adverse effects of both mechanisms and lead to improved temperature performance. Here, we study the temperature performance of highly diagonal THz-QCLs with high barriers. Our analysis uncovers an additional leakage channel which is the thermal excitation of carriers into bounded higher energy levels, rather than the escape into the continuum. Based on this understanding, we have designed a structure with an increased intersubband spacing between the upper lasing level and excited states in a highly diagonal THz-QCL, which exhibits negative differential resistance even at room temperature. This result is a strong evidence for the effective suppression of the aforementioned leakage channel.

  14. Application of low level laser on skin cell lines

    CSIR Research Space (South Africa)

    Ndhundhuma, IM

    2010-01-01

    Full Text Available Lasers have emerged as powerful tools for tissue engineering. To examine cellular growth, and cell to cell interactions, in vitro skin models have been developed combining two major cell types of skin, keratinocytes and fibroblasts. The main...

  15. Double fillet lap of laser welding of thin sheet AZ31B Mg alloy

    Science.gov (United States)

    Ishak, Mahadzir; Salleh, M. N. M.

    2018-05-01

    In this paper, we describe the experimental laser welding of thin sheet AZ31B using double fillet lap joint method. Laser welding is capable of producing high quality weld seams especially for small weld bead on thin sheet product. In this experiment, both edges for upper and lower sheets were subjected to the laser beam from the pulse wave (PW) mode of fiber laser. Welded sample were tested their joint strength by tensile-shear strength method and the fracture loads were studied. Strength for all welded samples were investigated and the effect of laser parameters on the joint strength and appearances were studied. Pulsed energy (EP) from laser process give higher effect on joint strength compared to the welding speed (WS) and angle of irradiation (AOI). Highest joint strength was possessed by sample with high EP with the same value of WS and AOI. The strength was low due to the crack defect at the centre of weld region.

  16. Ultraviolet SO lasers optically pumped by a tunable, line-narrowed KrF laser

    International Nuclear Information System (INIS)

    Stuart, B.C.D.

    1992-06-01

    The feasibility of an ultraviolet energy storage laser based on the long-lived sulfur monoxide A 3 π-χ 3 Σ - electronic transition was investigated, and an ultraviolet laser based on the short-lived SO(B 3 Σ - -χ 3 Σ - ) transition was demonstrated and modeled. Both were optically pumped by a continuously tunable, line-narrowed KrF laser developed for efficient rotationally resolved excitation of SO. SO was produced by both microwave discharge and excimer laser photolysis of the precursor molecules SO 2 and SOCl 2 , with a maximum SO concentration (10 16 cm -3 ) generated by ArF (193 nm) photodissociation of SO 2 . Laser induced fluorescence of SO was used to study the excitation spectroscopy, vibrational branching ratios, lifetimes and deactivation rates. The radiative lifetime of SO(A 3 π 2 ,v' = 5) was measured to be 6.9 μs and that of SO(B,v' = 1) to be 33 ns. Lifetimes in the highly perturbed SO(B,v' = 2) level ranged from 28--90 ns. Measurements and modeling of the excitation saturation fluence as a function of buffer gas pressure determined what fraction of the ground state SO(X) molecules could be excited to SO(A) or SO(B). No evidence of excited state absorption was seen. Lasing on six new ultraviolet SO(B-X) vibrational bands in the range 262--315 nm was demonstrated. SO(B-X) pulse energies of up to 11 μJ were obtained and the gain coefficient was estimated to be 0.1 cm -1 . A multi-level rate equation model of the SO(B-X) excitation and lasing transitions, including collisional rotational mixing, described the dynamics of the lasing and measured output very well. Modeling showed and experiments confirmed that the maximum possible SO laser gain simply corresponded to saturating the excitation of a single rotational level. Collisional coupling of the rotational levels increased the laser output energy

  17. Hybrid Ti:Sapphire / KrF laser facility GARPUN for combined subpicosecond/nanosecond laser-matter interaction studies

    International Nuclear Information System (INIS)

    Zvorykin, V.D.; Ionin, A.A.; Konyashcenko, A.V.; Levchenko, A.O.; Krokhin, O.N.; Mesyats, G.A.; Molchanov, A.G.; Rorulev, M.A.

    2006-01-01

    Complete test of publication follows. Hybrid laser facility consisting of Ti:Sapphire front end, 3ω converter, and e-beam-pumped large-aperture KrF amplifiers is under construction to generate combined sub-picosecond/nanosecond pulses in UV spectral range at 248-nm wavelength. This is a part of the Petawatt excimer laser project started at P.N. Lebedev Physical Institute. In comparison with commonly used solid-state chirped-pulse amplifiers (CPA), KrF amplifiers have following advantages: (i) low-density gaseous matter with three orders of magnitude lower non-linear refraction index has a small value of B-integral and negligible pulse distortion; (ii) short radiation lifetime τ r = 6 ns of the upper laser level of KrF(B-X) transition (with accounting for collisions τ c ∼ 2 ns), that means the population inversion is recovered each 2 ns during the pumping time, which is typically τ p ≥ 100 ns for technical reasons. Thus, it might be possible eliminating of very costly large-aperture compressor gratings and to amplify both short τ sh c and long τ long ≥ τ c pulses in the same amplifiers, as a short pulse does not affect the gain during the most of pumping. This gives a unique opportunity for realization of fast-ignition scheme in Inertial Confinement Fusion using large-scale KrF drivers. The Ti:Sapphire front end 'Start 248M' currently operates with the following parameters: rep rate 10 Hz, pulse energy and duration at fundamental wavelength (744 nm) > 8 mJ and 0.5 mJ and 0.4 mJ, 740 nm) and multi-pass amplifier (10 Hz, > 15 mJ, 740 nm), both pumped by 2ω pulsed Lotis LS-2134 Nd:YAG laser (10 Hz, 10 ns, 532 nm) with distributed energies of 5 and 70 mJ, two-gratings compressor, and 3ω converter with two BBO crystals and total efficiency 8%. EMG 150MSC Lambda Physik KrF laser is used afterwards to generate ns pulses and to amplify fs pulses in its two separate discharge chambers. Two e-beam pumped KrF amplifiers Berdysh and GARPUN with active volumes 10

  18. A Comparative Evaluation of Low-Level Laser and Topical Steroid Therapies for the Treatment of Erosive-Atrophic Lichen Planus.

    Science.gov (United States)

    El Shenawy, Hanaa M; Eldin, Amany Mohy

    2015-09-15

    Oral lichen planus (OLP) is a chronic inflammatory disease that causes bilateral white striations, papules, or plaques on the buccal mucosa, tongue, and gingivae. Erythema, erosions, and blisters may or may not be present. Several empirical therapies have been used in the treatment of (OLP). To evaluate the effect of low level laser therapy (LLLT) versus topical steroids for the treatment of erosive-atrophic lichen planus. Twenty-four patients with erosive-atrophic (OLP) were categorized into two groups. In the first group patients were treated with 970 nm diode laser irradiation, while, in the second group patients used topical corticosteroids (0.1% triamcinolone acetonide orabase). The gender, medical history and pain score were recorded. The pain score was measured before and after treatment by visual analogue scale (VAS). Steroid-treated group (0.1% triamcinolone acetonide orabase) show reduced pain score than laser group. Topical steroids are more effective than LLLT. LLLT may be used as an alternative treatment for symptomatic OLP when steroids are contraindicated.

  19. Clinical application of the Nd-YAG and Ho-YAG lasers in otolaryngology: head and neck surgery

    Science.gov (United States)

    Kukwa, Andrzej; Tulibacki, Marek P.; Dudziec, Katarzyna; Wojtowicz, Piotr

    1997-10-01

    The authors present their clinical experience regarding the possibilities of application of Nd:YAG and Ho:YAG lasers for the treatment of disorders in the area of the upper respiratory tract sinuses and ears. This technique makes it possible to perform a number of procedures in local anesthesia which considerably improves the economic effectiveness of the treatment. In case of the Nd:YAG laser they have also utilized the effect of deep coagulation of the soft tissues, whereas the Ho:YAG laser energy was applied for the surgery of bone tissue. The surgeries performed using laser beam enabled very good effect of treatment. They are competitive compared wit the methods used by traditional surgery.

  20. Improvement of laser irradiation uniformity in GEKKO XII glass laser system

    International Nuclear Information System (INIS)

    Miyanaga, Noriaki; Matsuoka, Shinichi; Ando, Akinobu; Amano, Shinji; Nakatsuka, Masahiro; Kanabe, Tadashi; Jitsuno, Takahisa; Nakai, Sadao

    1995-01-01

    The uniform laser irradiation is one of key issues in the direct drive laser fusion research. The several key technologies for the uniform laser irradiation are reported. This paper includes the uniformity performance as a result of the introduction of the random phase plate, the partially coherent light and the beam smoothing by spectral dispersion into the New Gekko XI glass laser system. Finally the authors summarize the overall irradiation uniformity on the spherical target surface by considering the power imbalance effect. The technologies developed for the beam smoothing and the power balance control enable them to achieve the irradiation nonuniformities of around 1% level for a foot pulse and of a few % for a main drive pulse, respectively

  1. Method and system for communicating with a laser power driver

    Science.gov (United States)

    Telford, Steven

    2017-07-18

    A system for controlling a plurality of laser diodes includes an optical transmitter coupled to the laser diode driver for each laser diode. An optical signal including bi-phase encoded data is provided to each laser diode driver. The optical signal includes current level and pulse duration information at which each of the diodes is to be driven. Upon receiving a trigger signal, the laser diode drivers operate the laser diodes using the current level and pulse duration information to output a laser beam.

  2. Quantum cascade laser combs: effects of modulation and dispersion.

    Science.gov (United States)

    Villares, Gustavo; Faist, Jérôme

    2015-01-26

    Frequency comb formation in quantum cascade lasers is studied theoretically using a Maxwell-Bloch formalism based on a modal decomposition, where dispersion is considered. In the mid-infrared, comb formation persists in the presence of weak cavity dispersion (500 fs2 mm-1) but disappears when much larger values are used (30'000 fs2 mm-1). Active modulation at the round-trip frequency is found to induce mode-locking in THz devices, where the upper state lifetime is in the tens of picoseconds. Our results show that mode-locking based on four-wave mixing in broadband gain, low dispersion cavities is the most promising way of achieving broadband quantum cascade laser frequency combs.

  3. High power, short pulses ultraviolet laser for the development of a new x-ray laser

    International Nuclear Information System (INIS)

    Meixler, L.; Nam, C.H.; Robinson, J.; Tighe, W.; Krushelnick, K.; Suckewer, S.; Goldhar, J.; Seely, J.; Feldman, U.

    1989-04-01

    A high power, short pulse ultraviolet laser system (Powerful Picosecond-Laser) has been developed at the Princeton Plasma Physics Laboratory (PPPL) as part of experiments designed to generate shorter wavelength x-ray lasers. With the addition of pulse compression and a final KrF amplifier the laser output is expected to have reached 1/3-1/2 TW (10 12 watts) levels. The laser system, particularly the final amplifier, is described along with some initial soft x-ray spectra from laser-target experiments. The front end of the PP-Laser provides an output of 20--30 GW (10 9 watts) and can be focussed to intensities of /approximately/10 16 W/cm 2 . Experiments using this output to examine the effects of a prepulse on laser-target interaction are described. 19 refs., 14 figs

  4. Laser physics and a review of laser applications in dentistry for children.

    Science.gov (United States)

    Martens, L C

    2011-04-01

    The aim of this introduction to this special laser issue is to describe some basic laser physics and to delineate the potential of laser-assisted dentistry in children. A brief review of the available laser literature was performed within the scope of paediatric dentistry. Attention was paid to soft tissue surgery, caries prevention and diagnosis, cavity preparation, comfort of the patient, effect on bacteria, long term pulpal vitality, endodontics in primary teeth, dental traumatology and low level laser therapy. Although there is a lack of sufficient evidence taking into account the highest standards for evidence-based dentistry, it is clear that laser application in a number of different aetiologies for soft tissue surgery in children has proven to be successful. Lasers provide a refined diagnosis of caries combined with the appropriate preventive adhesive dentistry after cavity preparation. This will further lead to a new wave of micro-dentistry based on 'filling without drilling'. It has become clear from a review of the literature that specific laser applications in paediatric dentistry have gained increasing importance. It can be concluded that children should be considered as amongst the first patients for receiving laser-assisted dentistry.

  5. Tracheostomy Tube Ignition During Microlaryngeal Surgery Using Diode Laser: A Case Report

    Directory of Open Access Journals (Sweden)

    Hsun-Mo Wang

    2006-04-01

    Full Text Available Ignition of the tracheal tube during laser microlaryngeal surgery under general anesthesia is an uncommon complication with potentially serious consequences. We present here a case of a patient with glottic stenosis following endotracheal intubation, who experienced this potentially catastrophic combustion during endoscopic arytenoidectomy, using a diode laser under general anesthesia via 60% FiO2, with an airway fire occurring at the tracheostomy tube and causing tubal damage and obstruction. The anesthetic connecting tube was immediately disconnected and the tracheostomy tube replaced. No adverse consequences to this patient's upper airway were noted during follow-up visits. Higher oxygen concentrations, the presence of combustibles, and the narrowness of the surgical field during endolaryngeal diode laser surgery are risk factors for airway fires.

  6. The possibilities of applying infrared lasers in otolaryngology

    Science.gov (United States)

    Kukwa, Andrzej; Tulibacki, Marek P.; Wojtowicz, Piotr; Oledzka, Iwona; Obarska, Agnieszka

    2003-10-01

    The authors present their many years of experience in the area of laryngological surgery with various types of solid lasers. In our clinical practice we use Nd-YAG, Ho-YAG and Er-YAG surgical lasers. There are many reasons for applying lasers, depending on medical conditions. One of the most frequent cases are the nasal polyps, where surgical treatment is aimed at curing the results. For this type the procedures there was applied Nd-YAG laser, which has shortened the period of treatment and extended the remission. We also use this laser for mucal tissue corrections of the nasal conchs through deep coagulation effect. The above mentioned laser is also useful for the preventative treatment of granulation stenosis by removal of granulation tissue from different sections of the upper way; from the nose to the trachea.Other laser procedures in the nasal area include coagulation of Kisselbach locus, bleeding in Rendu-Osler disease, separating adhesions of the nasal concha from the nasal septum, coagulation of septal bleeding polyps, angiomas of different location, small papillomae of throat and nose, and reduction of hypertrophy nasopharyngeal mucoosa in OSAS patients, and uvolo-palato-pharyngoplasty (UPPP). Neodymium laser is also used for the management of neoplastic diseases in palliative and radical (CA. basocellulare) treatment for the resection of the premalignant changes (papilloma, leukoplakia) and early neoplastic changes of throat and larynx. Keloplasty in the area of larynx and trachea is performed with the use of Ho-YAG laser, with shallow effect, regardless of the density of tissue, enabling coagulation of vascular vessels. It enables non-traumatic resections of bone structures, such as the wall of maxillary sinus, nasal spine, or conchoplasty; the mucal tissue and the frame. Recent clinical tests are examining the possibilities of Er-YAG laser application for crushing calculus in the salivary ducts. Using lasers in laryngology enables their extensive

  7. Use of low-level laser therapy as monotherapy or concomitant therapy for male and female androgenetic alopecia.

    Science.gov (United States)

    Munck, Andréia; Gavazzoni, Maria Fernanda; Trüeb, Ralph M

    2014-04-01

    Androgenetic alopecia (AGA) is the most common form of hair loss in men and in women. Currently, minoxidil and finasteride are the treatments with the highest levels of medical evidence, but patients who exhibit intolerance or poor response to these treatments are in need of additional treatment modalities. The aim was to evaluate the efficacy and safety of low-level laser therapy (LLLT) for AGA, either as monotherapy or as concomitant therapy with minoxidil or finasteride, in an office-based setting. Retrospective observational study of male and female patients with AGA, treated with the 655 nm-HairMax Laser Comb(®), in an office-based setting. Efficacy was assessed with global photographic imaging. Of 32 patients (21 female, 11 male), 8 showed significant, 20 moderate, and 4 no improvement. Improvement was seen both with monotherapy and with concomitant therapy. Improvement was observed as early as 3 months and was sustained up to a maximum observation time of 24 months. No adverse reactions were reported. LLLT represents a potentially effective treatment for both male and female AGA, either as monotherapy or concomitant therapy. Combination treatments with minoxidil, finasteride, and LLLT may act synergistic to enhance hair growth.

  8. Demonstration of resonant photopumping of Mo VII by Mo XII for a VUV laser near 600 Angstrom

    International Nuclear Information System (INIS)

    Ilcisin, K.J.; Aumayr, F.; Schwob, J.L.; Suckewer, S.

    1993-09-01

    We present data of experiments on the resonant photopumping of Mo VII by Mo XII as a method of generating a coherent VUV source near 600 angstrom. The experiment is based on a scheme proposed by Feldman and Reader in which the 4p 6 -- 4p 5 6s transition in Mo VII in resonantly photopumped by the 5s 2 S 1/2 -- 4p 2 P 1/2 transition in Mo XII. Results of the laser produced plasma experiments show the successful enhancement of the population of the Mo VII 4p 5 6s upper lasing level when pumped by an adjacent Mo VII plasma. No enhancement was seen in a control experiment where the Mo VII plasma was pumped by a Zr X plasma. Improvements of the intensity of the Mo XII pump source, achieved using an additional pump laser, lead to the generation of a population inversion for the VUV transition

  9. Upper thoracic-spine disc degeneration in patients with cervical pain.

    Science.gov (United States)

    Arana, Estanislao; Martí-Bonmatí, Luis; Mollá, Enrique; Costa, Salvador

    2004-01-01

    To study the relationship of upper thoracic spine degenerative disc contour changes on MR imaging in patients with neck pain. The relation between upper thoracic and cervical spine degenerative disc disease is not well established. One hundred and fifty-six patients referred with cervical pain were studied. There were 73 women and 77 men with a mean age of 48.6 +/- 14.6 years (range, 19 to 83 years). All MR studies were performed with a large 23-cm FOV covering at least from the body of T4 to the clivus. Discs were coded as normal, protrusion/bulge or extrusion. Degenerative thoracic disc contour changes were observed in 13.4% of patients with cervical pain. T2-3 was the most commonly affected level of the upper thoracic spine, with 15 bulge/protrusions and one extrusion. Upper degenerative thoracic disc contour changes presented in older patients than the cervical levels (Student-Newman-Keuls test, P < 0.001). Degenerative disc contour changes at the C7-T1, T1-2, T2-3 and T3-4 levels were significantly correlated ( P = 0.001), but unrelated to any other disc disease, patient's gender or age. Degenerative cervical disc disease was closely related together ( P < 0.001), but not with any thoracic disc. A statistically significant relation was found within the upper thoracic discs, reflecting common pathoanatomical changes. The absence of relation to cervical segments is probably due to differences in their pathomechanisms.

  10. Upper thoracic-spine disc degeneration in patients with cervical pain

    Energy Technology Data Exchange (ETDEWEB)

    Arana, Estanislao; Marti-Bonmati, Luis; Costa, Salvador [Department of Radiology, Clinica Quiron, Avda Blasco Ibanez 14, 46010, Valencia (Spain); Molla, Enrique [Department of Radiology, Clinica Quiron, Avda Blasco Ibanez 14, 46010, Valencia (Spain); Department of Morphological Sciences, University of Valencia, Valencia (Spain)

    2004-01-01

    To study the relationship of upper thoracic spine degenerative disc contour changes on MR imaging in patients with neck pain. The relation between upper thoracic and cervical spine degenerative disc disease is not well established. One hundred and fifty-six patients referred with cervical pain were studied. There were 73 women and 77 men with a mean age of 48.6{+-}14.6 years (range, 19 to 83 years). All MR studies were performed with a large 23-cm FOV covering at least from the body of T4 to the clivus. Discs were coded as normal, protrusion/bulge or extrusion. Degenerative thoracic disc contour changes were observed in 13.4% of patients with cervical pain. T2-3 was the most commonly affected level of the upper thoracic spine, with 15 bulge/protrusions and one extrusion. Upper degenerative thoracic disc contour changes presented in older patients than the cervical levels (Student-Newman-Keuls test, P<0.001). Degenerative disc contour changes at the C7-T1, T1-2, T2-3 and T3-4 levels were significantly correlated (P=0.001), but unrelated to any other disc disease, patient's gender or age. Degenerative cervical disc disease was closely related together (P<0.001), but not with any thoracic disc. A statistically significant relation was found within the upper thoracic discs, reflecting common pathoanatomical changes. The absence of relation to cervical segments is probably due to differences in their pathomechanisms. (orig.)

  11. Upper thoracic-spine disc degeneration in patients with cervical pain

    International Nuclear Information System (INIS)

    Arana, Estanislao; Marti-Bonmati, Luis; Costa, Salvador; Molla, Enrique

    2004-01-01

    To study the relationship of upper thoracic spine degenerative disc contour changes on MR imaging in patients with neck pain. The relation between upper thoracic and cervical spine degenerative disc disease is not well established. One hundred and fifty-six patients referred with cervical pain were studied. There were 73 women and 77 men with a mean age of 48.6±14.6 years (range, 19 to 83 years). All MR studies were performed with a large 23-cm FOV covering at least from the body of T4 to the clivus. Discs were coded as normal, protrusion/bulge or extrusion. Degenerative thoracic disc contour changes were observed in 13.4% of patients with cervical pain. T2-3 was the most commonly affected level of the upper thoracic spine, with 15 bulge/protrusions and one extrusion. Upper degenerative thoracic disc contour changes presented in older patients than the cervical levels (Student-Newman-Keuls test, P<0.001). Degenerative disc contour changes at the C7-T1, T1-2, T2-3 and T3-4 levels were significantly correlated (P=0.001), but unrelated to any other disc disease, patient's gender or age. Degenerative cervical disc disease was closely related together (P<0.001), but not with any thoracic disc. A statistically significant relation was found within the upper thoracic discs, reflecting common pathoanatomical changes. The absence of relation to cervical segments is probably due to differences in their pathomechanisms. (orig.)

  12. Electron-beam initiated HF lasers

    International Nuclear Information System (INIS)

    Gerber, R.A.; Patterson, E.L.

    1975-01-01

    Electron beams were used to ignite hydrogen/fluorine mixtures, producing laser energies up to 4.2 kJ, and giving hope that this approach may soon produce energy levels suitable for laser-fusion studies. (auth)

  13. The thickness design of unintentionally doped GaN interlayer matched with background doping level for InGaN-based laser diodes

    Energy Technology Data Exchange (ETDEWEB)

    Chen, P.; Zhao, D. G., E-mail: dgzhao@red.semi.ac.cn; Jiang, D. S.; Zhu, J. J.; Liu, Z. S.; Yang, J.; Li, X.; Le, L. C.; He, X. G.; Liu, W.; Li, X. J.; Liang, F. [State Key Laboratory of Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China); Zhang, B. S.; Yang, H. [Key Laboratory of Nano-devices and Applications of CAS, Suzhou Institute of Nano-tech and Nano-bionics, Chinese Academy of Sciences, Suzhou 215123 (China); Zhang, Y. T.; Du, G. T. [State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130023 (China)

    2016-03-15

    In order to reduce the internal optical loss of InGaN laser diodes, an unintentionally doped GaN (u-GaN) interlayer is inserted between InGaN/GaN multiple quantum well active region and Al{sub 0.2}Ga{sub 0.8}N electron blocking layer. The thickness design of u-GaN interlayer matching up with background doping level for improving laser performance is studied. It is found that a suitably chosen u-GaN interlayer can well modulate the optical absorption loss and optical confinement factor. However, if the value of background doping concentration of u-GaN interlayer is too large, the output light power may decrease. The analysis of energy band diagram of a LD structure with 100 nm u-GaN interlayer shows that the width of n-side depletion region decreases when the background concentration increases, and may become even too small to cover whole MQW, resulting in a serious decrease of the output light power. It means that a suitable interlayer thickness design matching with the background doping level of u-GaN interlayer is significant for InGaN-based laser diodes.

  14. The thickness design of unintentionally doped GaN interlayer matched with background doping level for InGaN-based laser diodes

    Directory of Open Access Journals (Sweden)

    P. Chen

    2016-03-01

    Full Text Available In order to reduce the internal optical loss of InGaN laser diodes, an unintentionally doped GaN (u-GaN interlayer is inserted between InGaN/GaN multiple quantum well active region and Al0.2Ga0.8N electron blocking layer. The thickness design of u-GaN interlayer matching up with background doping level for improving laser performance is studied. It is found that a suitably chosen u-GaN interlayer can well modulate the optical absorption loss and optical confinement factor. However, if the value of background doping concentration of u-GaN interlayer is too large, the output light power may decrease. The analysis of energy band diagram of a LD structure with 100 nm u-GaN interlayer shows that the width of n-side depletion region decreases when the background concentration increases, and may become even too small to cover whole MQW, resulting in a serious decrease of the output light power. It means that a suitable interlayer thickness design matching with the background doping level of u-GaN interlayer is significant for InGaN-based laser diodes.

  15. Analysis of laser remote fusion cutting based on a mathematical model

    Energy Technology Data Exchange (ETDEWEB)

    Matti, R. S. [Department of Engineering Sciences and Mathematics, Luleå University of Technology, S-971 87 Luleå (Sweden); Department of Mechanical Engineering, College of Engineering, University of Mosul, Mosul (Iraq); Ilar, T.; Kaplan, A. F. H. [Department of Engineering Sciences and Mathematics, Luleå University of Technology, S-971 87 Luleå (Sweden)

    2013-12-21

    Laser remote fusion cutting is analyzed by the aid of a semi-analytical mathematical model of the processing front. By local calculation of the energy balance between the absorbed laser beam and the heat losses, the three-dimensional vaporization front can be calculated. Based on an empirical model for the melt flow field, from a mass balance, the melt film and the melting front can be derived, however only in a simplified manner and for quasi-steady state conditions. Front waviness and multiple reflections are not modelled. The model enables to compare the similarities, differences, and limits between laser remote fusion cutting, laser remote ablation cutting, and even laser keyhole welding. In contrast to the upper part of the vaporization front, the major part only slightly varies with respect to heat flux, laser power density, absorptivity, and angle of front inclination. Statistical analysis shows that for high cutting speed, the domains of high laser power density contribute much more to the formation of the front than for low speed. The semi-analytical modelling approach offers flexibility to simplify part of the process physics while, for example, sophisticated modelling of the complex focused fibre-guided laser beam is taken into account to enable deeper analysis of the beam interaction. Mechanisms like recast layer generation, absorptivity at a wavy processing front, and melt film formation are studied too.

  16. Analysis of laser remote fusion cutting based on a mathematical model

    International Nuclear Information System (INIS)

    Matti, R. S.; Ilar, T.; Kaplan, A. F. H.

    2013-01-01

    Laser remote fusion cutting is analyzed by the aid of a semi-analytical mathematical model of the processing front. By local calculation of the energy balance between the absorbed laser beam and the heat losses, the three-dimensional vaporization front can be calculated. Based on an empirical model for the melt flow field, from a mass balance, the melt film and the melting front can be derived, however only in a simplified manner and for quasi-steady state conditions. Front waviness and multiple reflections are not modelled. The model enables to compare the similarities, differences, and limits between laser remote fusion cutting, laser remote ablation cutting, and even laser keyhole welding. In contrast to the upper part of the vaporization front, the major part only slightly varies with respect to heat flux, laser power density, absorptivity, and angle of front inclination. Statistical analysis shows that for high cutting speed, the domains of high laser power density contribute much more to the formation of the front than for low speed. The semi-analytical modelling approach offers flexibility to simplify part of the process physics while, for example, sophisticated modelling of the complex focused fibre-guided laser beam is taken into account to enable deeper analysis of the beam interaction. Mechanisms like recast layer generation, absorptivity at a wavy processing front, and melt film formation are studied too

  17. Direct diode lasers with comparable beam quality to fiber, CO2, and solid state lasers

    Science.gov (United States)

    Huang, Robin K.; Chann, Bien; Burgess, James; Kaiman, Michael; Overman, Robert; Glenn, John D.; Tayebati, Parviz

    2012-03-01

    TeraDiode has produced kW-class ultra-high brightness fiber-coupled direct diode lasers. A fiber-coupled direct diode laser with a power level of 2,040 W from a 50 μm core diameter, 0.15 numerical aperture (NA) output fiber at a single center wavelength was demonstrated. This was achieved with a novel beam combining and shaping technique using COTS diode lasers. The fiber-coupled output corresponds to a Beam Parameter Product (BPP) of 3.75 mm-mrad and is the lowest BPP kW-class direct diode laser yet reported. This laser is suitable for industrial materials processing applications, including sheet metal cutting and welding. This 2-kW fiber-coupled direct diode laser has comparable brightness to that of industrial fiber lasers and CO2 lasers, and is over 10x brighter than state-of-the-art direct diode lasers.

  18. Excimer laser processing of inkjet-printed and sputter-deposited transparent conducting SnO2:Sb for flexible electronics

    International Nuclear Information System (INIS)

    Cranton, Wayne M.; Wilson, Sharron L.; Ranson, Robert; Koutsogeorgis, Demosthenes C.; Chi Kuangnan; Hedgley, Richard; Scott, John; Lipiec, Stephen; Spiller, Andrew; Speakman, Stuart

    2007-01-01

    The feasibility of low-temperature fabrication of transparent electrode elements from thin films of antimony-doped tin oxide (SnO 2 :Sb, ATO) has been investigated via inkjet printing, rf magnetron sputtering and post-deposition excimer laser processing. Laser processing of thin films on both glass and plastic substrates was performed using a Lambda Physik 305i excimer laser, with fluences in the range 20-100 mJ cm -2 reducing sheet resistance from as-deposited values by up to 3 orders of magnitude. This is consistent with TEM analysis of the films that shows a densification of the upper 200 nm of laser-processed regions

  19. Laser Safety Evaluation of the MILES and Mini MILES Laser Emitting Components; TOPICAL

    International Nuclear Information System (INIS)

    AUGUSTONI, ARNOLD L.

    2002-01-01

    Laser safety evaluation and output emission measurements were performed (during October and November 2001) on SNL MILES and Mini MILES laser emitting components. The purpose, to verify that these components, not only meet the Class 1 (eye safe) laser hazard criteria of the CDRH Compliance Guide for Laser Products and 21 CFR 1040 Laser Product Performance Standard; but also meet the more stringent ANSI Std. z136.1-2000 Safe Use of Lasers conditions for Class 1 lasers that govern SNL laser operations. The results of these measurements confirmed that all of the Small Arms Laser Transmitters, as currently set (''as is''), meet the Class 1 criteria. Several of the Mini MILES Small Arms Transmitters did not. These were modified and re-tested and now meet the Class 1 laser hazard criteria. All but one System Controllers (hand held and rifle stock) met class 1 criteria for single trigger pulls and all presented Class 3a laser hazard levels if the trigger is held (continuous emission) for more than 5 seconds on a single point target. All units were Class 3a for ''aided'' viewing. These units were modified and re-tested and now meet the Class 1 hazard criteria for both ''aided'' as well as ''unaided'' viewing. All the Claymore Mine laser emitters tested are laser hazard Class 1 for both ''aided'' as well as ''unaided'' viewing

  20. A New Orthodontic Appliance with a Mini Screw for Upper Molar Distalization.

    Science.gov (United States)

    Ozkalayci, Nurhat; Yetmez, Mehmet

    2016-01-01

    The aim of this study is to present a new upper molar distalization appliance called Cise distalizer designed as intraoral device supported with orthodontic mini screw for upper permanent molar distalization. The new appliance consists of eight main components. In order to understand the optimum force level, the appliance under static loading is tested by using strain gage measurement techniques. Results show that one of the open coils produces approximately 300 gr distalization force. Cise distalizer can provide totally 600 gr distalization force. This range of force level is enough for distalization of upper first and second molar teeth.

  1. Effects of low-level laser irradiation on the pathogenicity of Candida albicans: in vitro and in vivo study.

    Science.gov (United States)

    Seyedmousavi, Seyedmojtaba; Hashemi, Seyed Jamal; Rezaie, Sasan; Fateh, Mohsen; Djavid, Gholamreza Esmaeeli; Zibafar, Ensieh; Morsali, Farhad; Zand, Nasrin; Alinaghizadeh, Mohammadreza; Ataie-Fashtami, Leila

    2014-06-01

    The purpose of this study was to evaluate the effects of low-level laser irradiation (LLLI) on the in vitro growth characteristics and in vivo pathogenicity of Candida albicans in a murine model in the absence of a photosensitizer. C. albicans is an opportunistic commensal organism that causes a wide variety of diseases in human beings, ranging from superficial infections to life-threatening invasive candidiasis. The incidence of C. albicans infection is increasing, because of the greater frequency of acquired immunodeficiency conditions. A high recurrence rate has been reported for vulvovaginal and oral candidiasis, despite the best available treatments. Therefore, the search for new treatment modalities seems quite rational. Candida culture plates were exposed to common clinical energies of LLLI: 3, 5, 10, and 20 J at 685 nm (BTL Laser 5000, Medicinos Projektai, Czech Republic, Prague, max power output 50 mW) and 3, 5, 10, 30, and 50 J at 830 nm (BTL Laser 5000, Medicinos Projektai, Czech Republic, Prague, max power output 400 mW). Following LLLI with energies >10 J at both 685 and 830 nm wavelengths, statistically significant effects were observed in vitro on the turbidimetric growth kinetics of C. albicans and in vivo on the survival rate of infected mice (p value ≤ 0.05). Therefore, this energy could be considered a threshold for clinical investigation. Translating our data into the clinical setting, it can be proposed that a direct laser-based approach without using a photosensitizing dye can significantly reduce the pathogenicity of Candida albicans. It can also be concluded that laser light at specific wavelengths could be a possible promising novel treatment for superficial and mucocutaneous C. albicans infections.

  2. Predictability of prototype flash flood events in the Western Mediterranean under uncertainties of the precursor upper-level disturbance: the HYDROPTIMET case studies

    Directory of Open Access Journals (Sweden)

    R. Romero

    2005-01-01

    uncertainty in the representation of the upper-level disturbance and the necessity to cope with it within the operational context when attempting to issue short to mid-range numerical weather predictions of these high impact weather events, a systematic exploration of the predictability of the three selected case studies subject to uncertainties in the representation of the upper-level precursor disturbance is carried out in this paper. The study is based on an ensemble of mesoscale numerical simulations of each event with the MM5 non-hydrostatic model after perturbing in a systematic way the upper-level disturbance, in the sense of displacing slightly this disturbance upstream/downstream along the zonal direction and intensifying/weakening its amplitude. These perturbations are guided by a previous application of the MM5-adjoint model, which consistently shows high sensitivities of the dynamical control of the heavy rain to the flow configuration about the upper-level disturbance on the day before, thus confirming the precursor characteristics of this agent. The perturbations are introduced to the initial conditions by applying a potential vorticity (PV inversion procedure to the positive PV anomaly associated with the upper-level disturbance, and then using the inverted fields (wind, temperature and geopotential to modify under a physically consistent balance the model initial fields. The results generally show that the events dominated by mesoscale low-level disturbances (Catalogne and last stage of the Piémont episode are very sensitive to the initial uncertainties, such that the heavy rain location and magnitude are in some of the experiments strongly changed in response to the 'forecast errors' of the cyclone trajectory, intensity, shape and translational speed. In contrast, the other situations (Cévennes and initial stage of the Piémont episode, dominated by a larger scale system wich basically acts to guarantee the establishment and persistence of the southerly LLJ

  3. Biological bases of the maximum permissible exposure levels of the UK laser standard BS 4803: 1983

    International Nuclear Information System (INIS)

    McKinlay, A.F.; Harlen, F.

    1983-10-01

    The use of lasers has increased greatly over the past 15 years or so, to the extent that they are now used routinely in many occupational and public situations. There has been an increasing awareness of the potential hazards presented by lasers and substantial efforts have been made to formulate safety standards. In the UK the relevant Safety Standard is the British Standards Institution Standard BS 4803. This Standard was originally published in 1972 and a revision has recently been published (BS 4803: 1983). The revised standard has been developed using the American National Standards Institute Standard, ANSI Z136.1 (1973 onwards), as a model. In other countries, national standards have been similarly formulated, resulting in a large measure of international agreement through participation in the work of the International Electrotechnical Commission (IEC). The bases of laser safety standards are biophysical data on threshold injury effects, particularly on the retina, and the development of theoretical models of damage mechanisms. This report deals in some detail with the mechanisms of injury from over exposure to optical radiations, in particular with the dependency of the type and degree of damage on wavelength, image size and pulse duration. The maximum permissible exposure levels recommended in BS 4803: 1983 are compared with published data for damage thresholds and the adequacy of the standard is discussed. (author)

  4. Analysis of 1997–2008 groundwater level changes in the upper Deschutes Basin, Central Oregon

    Science.gov (United States)

    Gannett, Marshall W.; Lite, Kenneth E.

    2013-01-01

    Groundwater-level monitoring in the upper Deschutes Basin of central Oregon from 1997 to 2008 shows water-level declines in some places that are larger than might be expected from climate variations alone, raising questions regarding the influence of groundwater pumping, canal lining (which decreases recharge), and other human influences. Between the mid-1990s and mid-2000s, water levels in the central part of the basin near Redmond steadily declined as much as 14 feet. Water levels in the Cascade Range, in contrast, rose more than 20 feet from the mid-1990s to about 2000, and then declined into the mid-2000s, with little or no net change. An existing U.S. Geological Survey regional groundwater-flow model was used to gain insights into groundwater-level changes from 1997 to 2008, and to determine the relative influence of climate, groundwater pumping, and irrigation canal lining on observed water-level trends. To utilize the model, input datasets had to be extended to include post-1997 changes in groundwater pumping, changes in recharge from precipitation, irrigation canal leakage, and deep percolation of applied irrigation water (also known as on-farm loss). Mean annual groundwater recharge from precipitation during the 1999–2008 period was 25 percent less than during the 1979–88 period because of drying climate conditions. This decrease in groundwater recharge is consistent with measured decreases in streamflow and discharge to springs. For example, the mean annual discharge of Fall River, which is a spring-fed stream, decreased 12 percent between the 1979–88 and 1999–2008 periods. Between the mid-1990s and late 2000s, groundwater pumping for public-supply and irrigation uses increased from about 32,500 to 52,000 acre-feet per year, partially because of population growth. Between 1997 and 2008, the rate of recharge from leaking irrigation canals decreased by about 58,000 acre-feet per year as a result of lining and piping of canals. Decreases in recharge

  5. Determination of the Acid Dissociation Constant of a Phenolic Acid by High Performance Liquid Chromatography: An Experiment for the Upper Level Analytical Chemistry Laboratory

    Science.gov (United States)

    Raboh, Ghada

    2018-01-01

    A high performance liquid chromatography (HPLC) experiment for the upper level analytical chemistry laboratory is described. The students consider the effect of mobile-phase composition and pH on the retention times of ionizable compounds in order to determine the acid dissociation constant, K[subscript a], of a phenolic acid. Results are analyzed…

  6. Low-level laser therapy induces an upregulation of collagen gene expression during the initial process of bone healing: a microarray analysis

    Science.gov (United States)

    Tim, Carla Roberta; Bossini, Paulo Sérgio; Kido, Hueliton Wilian; Malavazi, Iran; von Zeska Kress, Marcia Regina; Carazzolle, Marcelo Falsarella; Rennó, Ana Cláudia; Parizotto, Nivaldo Antonio

    2016-08-01

    This study investigates the histological modifications produced by low level laser therapy (LLLT) on the first day of bone repair, as well as evaluates the LLLT effects on collagen expression on the site of a fracture. Twenty Wistar rats were distributed into a control group (CG) and a laser group (LG). Laser irradiation of Ga-Al-As laser 830 nm, 30 mW, 94 s, 2.8 J was performed in five sessions. Animals were euthanized on day 5 postsurgery. Histopathological analysis showed that LLLT was able to increase deposition of granulation tissue and newly formed bone at the site of the injury. In addition, picrosirius analysis showed that collagen fiber organization in the LG was enhanced compared to CG. Microarray analysis demonstrated that LLLT produced an upregulation type I collagen (COL-I). Immunohistochemical analysis revealed that the subjects that were treated presented a higher immunoexpression of COL-I. Our findings indicated that LLLT improves bone healing by producing a significant increase in the expression of collagen genes.

  7. Additively Manufactured Low Cost Upper Stage Combustion Chamber

    Science.gov (United States)

    Protz, Christopher; Cooper, Ken; Ellis, David; Fikes, John; Jones, Zachary; Kim, Tony; Medina, Cory; Taminger, Karen; Willingham, Derek

    2016-01-01

    Over the past two years NASA's Low Cost Upper Stage Propulsion (LCUSP) project has developed Additive Manufacturing (AM) technologies and design tools aimed at reducing the costs and manufacturing time of regeneratively cooled rocket engine components. High pressure/high temperature combustion chambers and nozzles must be regeneratively cooled to survive their operating environment, causing their design fabrication to be costly and time consuming due to the number of individual steps and different processes required. Under LCUSP, AM technologies in Sintered Laser Melting (SLM) GRCop-84 and Electron Beam Freeform Fabrication (EBF3) Inconel 625 have been significantly advanced, allowing the team to successfully fabricate a 25k-class regenerative chamber. Estimates of the costs and schedule of future builds indicate cost reductions and significant schedule reductions will be enabled by this technology. Characterization of the microstructural and mechanical properties of the SLM-produced GRCop-84, EBF3 Inconel 625 and the interface layer between the two has been performed and indicates the properties will meet the design requirements. The LCUSP chamber is to be tested with a previously demonstrated SLM injector in order to advance the Technology Readiness Level (TRL) and demonstrate the capability of the application of these processes. NASA is advancing these technologies to reduce cost and schedule for future engine applications and commercial needs.

  8. Implementation of laser technology and treatment at county level in the Swedish Public Dental Service.

    Science.gov (United States)

    Bergholm, Åsa; Östberg, Anna-Lena; Gabre, Pia

    2014-01-01

    The aim of this study was to obtain an understanding of the factors that affected the way new technology and methods were used in dentistry after a training program. A qualitative research method was used to collect data. Nine dentists working in the Public Dental Service (PDS) in Uppsala County in Sweden agreed to be interviewed in the study. They worked in five different clinics, all with laser equipment, and had received training in the use of lasers. The interviews were tape recorded and transcribed, and were analysed using manifest and latent qualitative content analysis. The categories in this study were identified as "Prerequisites and obstacles to imple- mentation", "Attitudes to laser technology and treatments" and "Laser technology in the future'". The dentists described working with lasers as complicated and problematic. They had concerns about the method relating to the working environment, evidence of efficacy of treatment, costs, and benefits for patients and dentists. The main finding was that the decision to adopt the technology seemed to be based on individual perceptions of the value of lasers compared to other ways of achieving the same goal. They provided uniform proposals regarding how an organization should implement new methods, including an emphasis on the importance of preparation and having opportunities to be able to test and evaluate the technology. Another important factor was support from surrounding staff, colleagues and management. Despite all the barriers, the respondents were positive about working with lasers in the future, mainly due to their belief that patients would demand laser treatment. In conclusion both individual and organizational factors affected the extent to which the respondents used the laser. The main finding was the individual perception of the value of lasers compared to other methods which could achieve the same goal.

  9. Tunable femtosecond Cherenkov fiber laser

    DEFF Research Database (Denmark)

    Liu, Xiaomin; Svane, Ask Sebastian; Lægsgaard, Jesper

    2014-01-01

    We demonstrate electrically-tunable femtosecond Cherenkov fiber laser output at the visible range. Using an all-fiber, self-starting femtosecond Yb-doped fiber laser as the pump source and nonlinear photonic crystal fiber link as the wave-conversion medium, ultrafast, milliwatt-level, tunable...... and spectral isolated Cherenkov radiation at visible wavelengths are reported. Such a femtosecond Cherenkov laser source is promising for practical biophotonics applications....

  10. Laser spectroscopy and its applications

    International Nuclear Information System (INIS)

    Radziemski, L.J.; Solarz, R.W.; Paisner, J.A.

    1987-01-01

    Laser spectroscopy has applications in diverse fields ranging from combustion studies and trace-sample detection to biological research. At the same time, it has also contributed greatly to the discovery of hundreds of new lasers. This symbiotic relationship has promoted an especially rapid expansion of the field. This book provides a review of the subject. It includes, for example, chapters on laser isotope separation techniques, enabling scientists to compare their relative advantages and drawbacks. This volume also gives numerous tables that summarize important features of lasers, experiments, and parameters for quick reference. In addition, it presents diagrams for visualizing rotational molecular energy levels of high J in order to enhance our understanding of molecular motions and their relationship to molecular energy levels. Offering insights into how experts think this technology will improve, it considers research and development in each topic discussed

  11. Modélisation du procédé de soudage hybride Arc / Laser par une approche level set application aux toles d'aciers de fortes épaisseurs A level-set approach for the modelling of hybrid arc/laser welding process application for high thickness steel sheets joining

    Directory of Open Access Journals (Sweden)

    Desmaison Olivier

    2013-11-01

    Full Text Available Le procédé de soudage hybride Arc/Laser est une solution aux assemblages difficiles de tôles de fortes épaisseurs. Ce procédé innovant associe deux sources de chaleur : un arc électrique produit par une torche MIG et une source laser placée en amont. Ce couplage améliore le rendement du procédé, la qualité du cordon et les déformations finales. La modélisation de ce procédé par une approche Level Set permet une prédiction du développement du cordon et du champ de température associé. La simulation du soudage multi-passes d'une nuance d'acier 18MnNiMo5 est présentée ici et les résultats sont comparés aux observations expérimentales. The hybrid arc/laser welding process has been developed in order to overcome the difficulties encountered for joining high thickness steel sheets. This innovative process gathers two heat sources: an arc source developed by a MIG torch and a pre-located laser source. This coupling improves the efficiency of the process, the weld bead quality and the final deformations. The Level-Set approach for the modelling of this process enables the prediction of the weld bead development and the temperature field evolution. The simulation of the multi-passes welding of a 18MnNiMo5 steel grade is detailed and the results are compared to the experimental observations.

  12. 50: EFFECT OF LOW-LEVEL LASER THERAPY IN THE TREATMENT OF BURNING MOUTH SYNDROME: A SYSTEMATIC REVIEW AND META-ANALYSIS

    Science.gov (United States)

    Amirzade-Iranaq, Mohammad Hossein; Masoumil, S. M. R.

    2017-01-01

    Background and aims low level laser therapy (LLLT) has been used in the treatment of burning mouth syndrome (BMS) for recent years and the role of intervention has not proven accurately. We conducted a systematic review and meta-analysis to investigate the efficacy of low level laser therapy (LLLT) in the treatment of burning mouth syndrome (BMS). Methods We performed a search on PubMed, Embase, Scopus and Web of Science for relevant studies that met our eligibility criteria. English language restriction included and only randomized clinical trials on humans entered to this study. Data extraction: 63 Records identified through database searching and also 1 Additional records identified by hand-searching. After removing duplicates and studies not meeting inclusion criteria like case reports and animal studies, at last 9 Full-text articles assessed for eligibility. Quality assessment of this study was executed by using the Critical Appraisal Skills Programme (CASP). Eventually 7 of these studies were selected for meta-analysis by Comprehensive meta-analysis version 2. Results From Total of 9 studies 7 randomized controlled trials (RCTs) studies including BMS patients were selected. Our results shows us LLLT can relieve the sensation of mouth. WMD in visual analog scale (VAS) pain outcome score after treatment was significantly lower in the experimental groups compared with control groups (WMD=−11.42 [95% CI= −16.82, −9.72], I(2) =0%). Conclusion low level laser therapy is an effective therapeutic intervention in reduction of the symptoms of burning mouth syndrome.

  13. Laser adaptive holographic hydrophone

    Energy Technology Data Exchange (ETDEWEB)

    Romashko, R V; Kulchin, Yu N; Bezruk, M N; Ermolaev, S A [Institute of Automation and Control Processes, Far Eastern Branch of the Russian Academy of Sciences, Vladivostok (Russian Federation)

    2016-03-31

    A new type of a laser hydrophone based on dynamic holograms, formed in a photorefractive crystal, is proposed and studied. It is shown that the use of dynamic holograms makes it unnecessary to use complex optical schemes and systems for electronic stabilisation of the interferometer operating point. This essentially simplifies the scheme of the laser hydrophone preserving its high sensitivity, which offers the possibility to use it under a strong variation of the environment parameters. The laser adaptive holographic hydrophone implemented at present possesses the sensitivity at a level of 3.3 mV Pa{sup -1} in the frequency range from 1 to 30 kHz. (laser hydrophones)

  14. Low-level laser therapy in the prevention of radiotherapy-induced xerostomia and oral mucositis

    International Nuclear Information System (INIS)

    Lopes, Carlos de Oliveira; Mas, Josepa Rigau I.; Zangaro, Renato Amaro

    2006-01-01

    Objective: to verify if the use of InGaAIP laser with 685 nm wave length can reduce the xerostomy incidence, the oral mucositis severity and the pain related to mucositis in patients with head and neck cancer submitted to radiotherapy. Objective: sixty patients presenting head and neck carcinoma were submitted to radiotherapy with daily doses of 1.8 to 2.0 Gy and a final dose of 45 to 72 Gy. The salivary volume was evaluated in the first and fifteenth days, at the end of the treatment and after 15 and 30 days. The oral mucositis was evaluated on a weekly basis. Twenty-nine patients were submitted to radiotherapy without laser and 31 were submitted to radiotherapy and laser with daily doses of 2 joules/cm 2 in predetermined areas of the oral mucosa and the parotid and submandibular glands. Results: in the group submitted to radiotherapy and laser the incidence of mucositis (p < 0.001) and pain (p < 0.016) was significantly lower and the salivary volume (p < 0.001) was kept higher during and after the treatment. Conclusion: the group of patients submitted to radiotherapy and laser had lower incidence of xerostomy, oral mucositis and pain when compared to the group treated with radiotherapy without laser, producing statistically significant results. (author)

  15. Laser lipolysis: skin tightening in lipoplasty using a diode laser.

    Science.gov (United States)

    Wolfenson, Moisés; Hochman, Bernardo; Ferreira, Lydia Massako

    2015-05-01

    New devices have been developed for surgical repair of deformities caused by localized fat deposits associated with skin laxity. The use of these devices requires the adoption of safety parameters. The aim of this study was to investigate skin tightening by laser lipolysis, using a dual-wavelength diode laser. This prospective, cross-sectional study was conducted between June of 2008 and July of 2010 with 41 consecutive patients who underwent laser lipolysis to correct contour deformities. Laser lipolysis was performed with a diode laser operating at two wavelengths (924 and 975 nm) controlled independently, and using three different tip lengths, allowing treatment of small, medium, and large areas of adipose tissue. The procedure was performed under local anesthesia in a surgical setting. To calculate the optimal cumulative energy, a total energy dose of 5 kJ/10 × 10-cm skin area was used as a safety parameter to prevent treatment complications. The circumferences of body regions were measured preoperatively, immediately after surgery, and 90 days later. Measurements were compared using the Wilcoxon test at a significance level of 0.05 (p Laser lipolysis results in progressive skin tightening over time. Therapeutic, IV.

  16. Inertial fusion by laser

    International Nuclear Information System (INIS)

    Dautray, R.; Watteau, J.-P.

    1980-01-01

    Following a brief historical survey of research into the effects of interaction of laser with matter, the principles of fusion by inertial confinement are described and the main parameters and possible levels given. The development of power lasers is then discussed with details of performances of the main lasers used in various laboratories, and with an assessment of the respective merits of neodymium glass, carbon dioxide or iodine lasers. The phenomena of laser radiation and its interaction with matter is then described, with emphasis on the results of experiments concerned with target implosion with the object of compressing and heating the mixture of heavy hydrogen and tritium to be ignited. Finally, a review is made of future possibilities opened up by the use of large power lasers which have recently become operational or are being constructed, and the ground still to be covered before a reactor can be produced [fr

  17. High-powered CO2 -lasers and noise control

    Science.gov (United States)

    Honkasalo, Antero; Kuronen, Juhani

    High-power CO2 -lasers are being more and more widely used for welding, drilling and cutting in machine shops. In the near future, different kinds of surface treatments will also become routine practice with laser units. The industries benefitting most from high power lasers will be: the automotive industry, shipbuilding, the offshore industry, the aerospace industry, the nuclear and the chemical processing industries. Metal processing lasers are interesting from the point of view of noise control because the working tool is a laser beam. It is reasonable to suppose that the use of such laser beams will lead to lower noise levels than those connected with traditional metal processing methods and equipment. In the following presentation, the noise levels and possible noise-control problems attached to the use of high-powered CO2 -lasers are studied.

  18. Analgesic effects of preinjection low-level laser/light therapy (LLLT) before third molar surgery: a double-blind randomized controlled trial

    NARCIS (Netherlands)

    Tuk, Jacco G. C.; van Wijk, Arjen J.; Mertens, Ine C.; Keleş, Zühal; Lindeboom, Jérôme A. H.; Milstein, Dan M. J.

    2017-01-01

    The aim of this study was to evaluate the analgesic effects of low-level laser therapy (LLLT) on preinjection sites in patients scheduled for third molar removal. This double-blind randomized controlled trial included 163 healthy patients undergoing third molar extractions. The study participants

  19. Technique for Increasing the Selectivity of the Method of Laser Fragmentation/Laser-Induced Fluorescence

    Science.gov (United States)

    Bobrovnikov, S. M.; Gorlov, E. V.; Zharkov, V. I.

    2018-05-01

    A technique for increasing the selectivity of the method of detecting high-energy materials (HEMs) based on laser fragmentation of HEM molecules with subsequent laser excitation of fluorescence of the characteristic NO fragments from the first vibrational level of the ground state is suggested.

  20. Effect of low-level laser irradiation on osteoblast-like cells cultured on porous hydroxyapatite scaffolds

    Directory of Open Access Journals (Sweden)

    Serena Incerti Parenti

    2013-09-01

    Full Text Available OBJECTIVE: To determine the effect of laser irradiation at a low dose on human osteoblastlike cells. Materials and methods: 32 porous hydroxyapatite scaffolds currently used for bone tissue engineering were seeded with MG63 cells and irradiated or not with a GaAlAs diode laser (wavelength 915 nm, dose 2 J/cm² using different power density and exposure duration. RESULTS: After 72-h incubation, cells showed well spread morphology and good adhesion on both laser-treated and untreated scaffolds. Laser irradiation did not interfere in cell viability and proliferation as compared with the non-irradiated controls. CONCLUSION: This study suggests that there is no effect of 915 nm laser irradiation at a dose of 2 J/cm² on the proliferation rate of MG63 cells. Future investigations are needed to compare different dose and wavelength regimens in order to determine the optimal set of laser parameters for maximum cell yield and safe clinical application.