WorldWideScience

Sample records for university gas spectrometer

  1. Gas Chromatic Mass Spectrometer

    Wey, Chowen

    1995-01-01

    Gas chromatograph/mass spectrometer (GC/MS) used to measure and identify combustion species present in trace concentration. Advanced extractive diagnostic method measures to parts per billion (PPB), as well as differentiates between different types of hydrocarbons. Applicable for petrochemical, waste incinerator, diesel transporation, and electric utility companies in accurately monitoring types of hydrocarbon emissions generated by fuel combustion, in order to meet stricter environmental requirements. Other potential applications include manufacturing processes requiring precise detection of toxic gaseous chemicals, biomedical applications requiring precise identification of accumulative gaseous species, and gas utility operations requiring high-sensitivity leak detection.

  2. Electron spectrometer for gas-phase spectroscopy

    Bozek, J.D.; Schlachter, A.S. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)

    1997-04-01

    An electron spectrometer for high-resolution spectroscopy of gaseous samples using synchrotron radiation has been designed and constructed. The spectrometer consists of a gas cell, cylindrical electrostatic lens, spherical-sector electron energy analyzer, position-sensitive detector and associated power supplies, electronics and vacuum pumps. Details of the spectrometer design are presented together with some representative spectra.

  3. Gas-dust-impact mass spectrometer

    Semkin, N D; Myasnikov, S V; Pomelnikov, R A

    2002-01-01

    Paper describes design of a mass spectrometer to study element composition of micro meteorite and man-made particles in space. Paper describes a way to improve resolution of mass spectrometer based on variation of parameters of accelerating electric field in time. The advantage of the given design of mass spectrometer in comparison with similar ones is its large operating area and higher resolution at the comparable weight and dimensions. Application of a combined design both for particles and for gas enables to remove space vehicle degassing products from the spectrum and, thus, to improve reliability of the acquired information, as well as, to acquire information on a gas component of the external atmosphere of a space vehicle

  4. Portable spectrometer monitors inert gas shield in welding process

    Grove, E. L.

    1967-01-01

    Portable spectrometer using photosensitive readouts, monitors the amount of oxygen and hydrogen in the inert gas shield of a tungsten-inert gas welding process. A fiber optic bundle transmits the light from the welding arc to the spectrometer.

  5. Multiplate ionization total absorption spectrometer with a compressed gas

    Baskakov, V.I.; Dolgoshein, B.A.; Kantserov, V.A.

    1978-01-01

    The characteristics of a multiplate total absorption spectrometer working with the compressed xenon (up to 25 atm) containing up to 23 radiation lengths of matter are studied. The dependence of the spectrometer energy resolution on the detecting matter density, on the material and thickness of the absorber plates has been studied. The ability of the spectrometer with a tungsten absorber to select hadrons and electrons with P=6 GeV/c by total energy release and characteristics of the cascade longitudinal development has been also studied. The gas spectrometer as it is shown differs quite slightly from the similar spectrometer with liquid argon as for its time resolution it is much better

  6. The University of Colorado OSO-8 spectrometer experiment. I

    Bruner, E.C. Jr.

    1977-01-01

    The optical design of the high resolution ultraviolet spectrometer prepared for the OSO-8 spacecraft by the University of Colorado is discussed. The instrument is a conventional 1 m Ebert-Fastie spectrometer fed by a Cassegrainian telescope. The instrument operates in the spectral range 1200 A to about 2000 A with spectral resolution of order 0.02 A. Spatial resolution is about 2.5 sec normal to the direction of the slit and is selectable from about 3 sec to 15' along the direction of the slit. Time resolution for the single spectrometer channel is selectable according to the needs of an individual observation and is limited to a maximum sampling rate of 40 ms per data point. The instrument is controlled by an internal general purpose computer. In this paper the author develops the performance requirements of the spectrometer and attempts to highlight some of the tradeoffs available to the instrument designer. (Auth.)

  7. High-pressure 3He gas scintillation neutron spectrometer

    Derzon, M.S.; Slaughter, D.R.; Prussin, S.G.

    1985-10-01

    A high-pressure, 3 He-Xe gas scintillation spectrometer has been developed for neutron spectroscopy on D-D fusion plasmas. The spectrometer exhibits an energy resolution of (121 +- 20 keV) keV (FWHM) at 2.5 MeV and an efficiency of (1.9 +- 0.4) x 10 -3 (n/cm 2 ) -1 . The contribution to the resolution (FWHM) from counting statistics is only (22 +- 3 keV) and the remainder is due predominantly to the variation of light collection efficiency with location of neutron events within the active volume of the detector

  8. Gas Measurement Using Static Fourier Transform Infrared Spectrometers.

    Köhler, Michael H; Schardt, Michael; Rauscher, Markus S; Koch, Alexander W

    2017-11-13

    Online monitoring of gases in industrial processes is an ambitious task due to adverse conditions such as mechanical vibrations and temperature fluctuations. Whereas conventional Fourier transform infrared (FTIR) spectrometers use rather complex optical and mechanical designs to ensure stable operation, static FTIR spectrometers do not require moving parts and thus offer inherent stability at comparatively low costs. Therefore, we present a novel, compact gas measurement system using a static single-mirror Fourier transform spectrometer (sSMFTS). The system works in the mid-infrared range from 650 cm - 1 to 1250 cm - 1 and can be operated with a customized White cell, yielding optical path lengths of up to 120 cm for highly sensitive quantification of gas concentrations. To validate the system, we measure different concentrations of 1,1,1,2-Tetrafluoroethane (R134a) and perform a PLS regression analysis of the acquired infrared spectra. Thereby, the measured absorption spectra show good agreement with reference data. Since the system additionally permits measurement rates of up to 200 Hz and high signal-to-noise ratios, an application in process analysis appears promising.

  9. A gas monitoring facility with a quadrupole mass spectrometer for the ZEUS transition-radiation chambers

    Kapp, U.

    1988-07-01

    A gas analysis facility for the ZEUS transition-radiation chambers based on a quadrupole mass spectrometer is described. After a description of the spectrometer, the vacuum system, and the software, some test results are presented. (HSI)

  10. Stitching Type Large Aperture Depolarizer for Gas Monitoring Imaging Spectrometer

    Liu, X.; Li, M.; An, N.; Zhang, T.; Cao, G.; Cheng, S.

    2018-04-01

    To increase the accuracy of radiation measurement for gas monitoring imaging spectrometer, it is necessary to achieve high levels of depolarization of the incoming beam. The preferred method in space instrument is to introduce the depolarizer into the optical system. It is a combination device of birefringence crystal wedges. Limited to the actual diameter of the crystal, the traditional depolarizer cannot be used in the large aperture imaging spectrometer (greater than 100 mm). In this paper, a stitching type depolarizer is presented. The design theory and numerical calculation model for dual babinet depolarizer were built. As required radiometric accuracies of the imaging spectrometer with 250 mm × 46 mm aperture, a stitching type dual babinet depolarizer was design in detail. Based on designing the optimum structural parmeters the tolerance of wedge angle refractive index, and central thickness were given. The analysis results show that the maximum residual polarization degree of output light from depolarizer is less than 2 %. The design requirements of polarization sensitivity is satisfied.

  11. STITCHING TYPE LARGE APERTURE DEPOLARIZER FOR GAS MONITORING IMAGING SPECTROMETER

    X. Liu

    2018-04-01

    Full Text Available To increase the accuracy of radiation measurement for gas monitoring imaging spectrometer, it is necessary to achieve high levels of depolarization of the incoming beam. The preferred method in space instrument is to introduce the depolarizer into the optical system. It is a combination device of birefringence crystal wedges. Limited to the actual diameter of the crystal, the traditional depolarizer cannot be used in the large aperture imaging spectrometer (greater than 100 mm. In this paper, a stitching type depolarizer is presented. The design theory and numerical calculation model for dual babinet depolarizer were built. As required radiometric accuracies of the imaging spectrometer with 250 mm × 46 mm aperture, a stitching type dual babinet depolarizer was design in detail. Based on designing the optimum structural parmeters,the tolerance of wedge angle,refractive index, and central thickness were given. The analysis results show that the maximum residual polarization degree of output light from depolarizer is less than 2 %. The design requirements of polarization sensitivity is satisfied.

  12. Recent Advances in Water Analysis with Gas Chromatograph Mass Spectrometers

    MacAskill, John A.; Tsikata, Edem

    2014-01-01

    We report on progress made in developing a water sampling system for detection and analysis of volatile organic compounds in water with a gas chromatograph mass spectrometer (GCMS). Two approaches are described herein. The first approach uses a custom water pre-concentrator for performing trap and purge of VOCs from water. The second approach uses a custom micro-volume, split-splitless injector that is compatible with air and water. These water sampling systems will enable a single GC-based instrument to analyze air and water samples for VOC content. As reduced mass, volume, and power is crucial for long-duration, manned space-exploration, these water sampling systems will demonstrate the ability of a GCMS to monitor both air and water quality of the astronaut environment, thereby reducing the amount of required instrumentation for long duration habitation. Laboratory prototypes of these water sampling systems have been constructed and tested with a quadrupole ion trap mass spectrometer as well as a thermal conductivity detector. Presented herein are details of these water sampling system with preliminary test results.

  13. The university of Colorado OSO-8 spectrometer experiment. Pt. 4

    Hansen, E.R.; Bruner, E.C. Jr.

    1979-01-01

    We discuss the remote operation of two high resolution ultraviolet spectrometers on the OSO-8 satellite; one prepared by the Laboratory for Planetary and Stellar Physics in Paris, France and the other by the Laboratory for Atmospheric and Space Physics at the University of Colorado at Boulder. Mission operations, from the Colorado facility, enabled the scientific observers to plan observations based on current solar data, interact with the observing program using real or near real-time data and commands, evaluate quick-look instrument data, and analyze the observations for publication. The scientists were supplied with daily solar images and satellite event timelines to aid in experiment planning. Command generation programs converted these observing plans into time-ordered, error-free commands for control of spacecraft and instrument functions. Real and near real-time data and commands via ground data lines were available for interactive target acquisition and instrument reconfiguration. An on-board computer system provided closed-loop target acquisition and instrument control. A sophisticated ground computer system was used for data line communications, data formatting, interactive scientific data display, and in-depth analysis. (orig.)

  14. Portable Gas Analyzer Based on Fourier Transform Infrared Spectrometer for Patrolling and Examining Gas Exhaust

    Yuntao Liang

    2015-01-01

    Full Text Available Aimed at monitoring emission of organic gases such as CH4, C2H6, C3H8, iso-C4H10, n-C4H10, C2H4, C3H6, C2H2, CO, and CO2, from coal mines, petroleum refineries, and other plants, a Fourier Transform Infrared (FT-IR spectrometer was used to develop a portable gas analyzer for patrolling and examining gas exhaust. Firstly, structure of the instrument was introduced. Then, a spectral analysis approach was presented. Finally, instrument was tested with standard gases and with actual gases emitted from a petroleum refinery. For the latter test, a gas chromatograph (GC was used as a reference instrument. The test results showed that the detection limit of every component of analyte was less than 10 × 10−6. The maximum test error of every analyte was less than 15 × 10−6 when its practical concentration was no more than 500 × 10−6. A final comparison showed that the result curves of analytes obtained with FT-IR spectrometer almost overlapped with those obtained with GC, and their resulting noise was less than 6.4% when the practical gas concentration was above 100 × 10−6. As a result, our instrument was suitable to be used as a portable instrument for monitoring exhaust gases.

  15. Mars Solar Balloon Landed Gas Chromatograph Mass Spectrometer

    Mahaffy, P.; Harpold, D.; Niemann, H.; Atreya, S.; Gorevan, S.; Israel, G.; Bertaux, J. L.; Jones, J.; Owen, T.; Raulin, F.

    1999-01-01

    A Mars surface lander Gas Chromatograph Mass Spectrometer (GCMS) is described to measure the chemical composition of abundant and trace volatile species and isotope ratios for noble gases and other elements. These measurements are relevant to the study of atmospheric evolution and past climatic conditions. A Micromission plan is under study where a surface package including a miniaturized GCMS would be delivered to the surface by a solar heated hot air balloon based system. The balloon system would be deployed about 8 km above the surface of Mars, wherein it would rapidly fill with Martian atmosphere and be heated quickly by the sun. The combined buoyancy and parachuting effects of the solar balloon result in a surface package impact of about 5 m/sec. After delivery of the package to the surface, the balloon would ascend to about 4 km altitude, with imaging and magnetometry data being taken for the remainder of the daylight hours as the balloon is blown with the Martian winds. Total atmospheric entry mass of this mission is estimated to be approximately 50 kg, and it can fit as an Ariane 5 piggyback payload. The GCMS would obtain samples directly from the atmosphere at the surface and also from gases evolved from solid phase material collected from well below the surface with a Sample Acquisition and Transport Mechanism (SATM). The experiment envisioned in the Mars Micromission described would obtain samples from a much greater depth of up to one meter below the surface, and would search for organic molecules trapped in ancient stratified layers well below the oxidized surface. Insitu instruments on upcoming NASA missions working in concert with remote sensing measurement techniques have the potential to provide a more detailed investigation of mineralogy and the extent of simple volatiles such as CO2 and H2O in surface and subsurface solid phase materials. Within the context of subsequent mission opportunities such as those provided by the Ariane 5 piggyback

  16. spectrometer

    J. K. Hedelius

    2016-08-01

    Full Text Available Bruker™ EM27/SUN instruments are commercial mobile solar-viewing near-IR spectrometers. They show promise for expanding the global density of atmospheric column measurements of greenhouse gases and are being marketed for such applications. They have been shown to measure the same variations of atmospheric gases within a day as the high-resolution spectrometers of the Total Carbon Column Observing Network (TCCON. However, there is little known about the long-term precision and uncertainty budgets of EM27/SUN measurements. In this study, which includes a comparison of 186 measurement days spanning 11 months, we note that atmospheric variations of Xgas within a single day are well captured by these low-resolution instruments, but over several months, the measurements drift noticeably. We present comparisons between EM27/SUN instruments and the TCCON using GGG as the retrieval algorithm. In addition, we perform several tests to evaluate the robustness of the performance and determine the largest sources of errors from these spectrometers. We include comparisons of XCO2, XCH4, XCO, and XN2O. Specifically we note EM27/SUN biases for January 2015 of 0.03, 0.75, –0.12, and 2.43 % for XCO2, XCH4, XCO, and XN2O respectively, with 1σ running precisions of 0.08 and 0.06 % for XCO2 and XCH4 from measurements in Pasadena. We also identify significant error caused by nonlinear sensitivity when using an extended spectral range detector used to measure CO and N2O.

  17. Trace gas absorption spectroscopy using laser difference-frequency spectrometer for environmental application

    Chen, W.; Cazier, F.; Boucher, D.; Tittel, F. K.; Davies, P. B.

    2001-01-01

    A widely tunable infrared spectrometer based on difference frequency generation (DFG) has been developed for organic trace gas detection by laser absorption spectroscopy. On-line measurements of concentration of various hydrocarbons, such as acetylene, benzene, and ethylene, were investigated using high-resolution DFG trace gas spectroscopy for highly sensitive detection.

  18. Characterisation of an ion source on the Helix MC Plus noble gas mass spectrometer - pressure dependent mass discrimination

    Zhang, X.

    2017-12-01

    Characterisation of an ion source on the Helix MC Plusnoble gas mass spectrometer - pressure dependent mass discrimination Xiaodong Zhang* dong.zhang@anu.edu.au Masahiko Honda Masahiko.honda@anu.edu.au Research School of Earth Sciences, The Australian National University, Canberra, Australia To obtain reliable measurements of noble gas elemental and isotopic abundances in a geological sample it is essential that the mass discrimination (instrument-induced isotope fractionation) of the mass spectrometer remain constant over the working range of noble gas partial pressures. It is known, however, that there are pressure-dependent variations in sensitivity and mass discrimination in conventional noble gas mass spectrometers [1, 2, 3]. In this study, we discuss a practical approach to ensuring that the pressure effect in the Helix MC Plus high resolution, multi-collector noble gas mass spectrometer is minimised. The isotopic composition of atmospheric Ar was measured under a range of operating conditions to test the effects of different parameters on Ar mass discrimination. It was found that the optimised ion source conditions for pressure independent mass discrimination for Ar were different from those for maximised Ar sensitivity. The optimisation can be achieved by mainly adjusting the repeller voltage. It is likely that different ion source settings will be required to minimise pressure-dependent mass discrimination for different noble gases. A recommended procedure for tuning an ion source to reduce pressure dependent mass discrimination will be presented. References: Honda M., et al., Geochim. Cosmochim. Acta, 57, 859 -874, 1993. Burnard P. G., and Farley K. A., Geochemistry Geophysics Geosystems, Volume 1, 2000GC00038, 2000. Mabry J., et al., Journal of Analytical Atomic Spectrometry, 27, 1012 - 1017, 2012.

  19. A hybrid thermal video and FTIR spectrometer system for rapidly locating and characterizing gas leaks

    Williams, David J.; Wadsworth, Winthrop; Salvaggio, Carl; Messinger, David W.

    2006-08-01

    Undiscovered gas leaks, known as fugitive emissions, in chemical plants and refinery operations can impact regional air quality and present a loss of product for industry. Surveying a facility for potential gas leaks can be a daunting task. Industrial leak detection and repair programs can be expensive to administer. An efficient, accurate and cost effective method for detecting and quantifying gas leaks would both save industries money by identifying production losses and improve regional air quality. Specialized thermal video systems have proven effective in rapidly locating gas leaks. These systems, however, do not have the spectral resolution for compound identification. Passive FTIR spectrometers can be used for gas compound identification, but using these systems for facility surveys is problematic due to their small field of view. A hybrid approach has been developed that utilizes the thermal video system to locate gas plumes using real time visualization of the leaks, coupled with the high spectral resolution FTIR spectrometer for compound identification and quantification. The prototype hybrid video/spectrometer system uses a sterling cooled thermal camera, operating in the MWIR (3-5 μm) with an additional notch filter set at around 3.4 μm, which allows for the visualization of gas compounds that absorb in this narrow spectral range, such as alkane hydrocarbons. This camera is positioned alongside of a portable, high speed passive FTIR spectrometer, which has a spectral range of 2 - 25 μm and operates at 4 cm -1 resolution. This system uses a 10 cm telescope foreoptic with an onboard blackbody for calibration. The two units are optically aligned using a turning mirror on the spectrometer's telescope with the video camera's output.

  20. Calibration of a Noble Gas Mass Spectrometer with an Atmospheric Argon Standard (Invited)

    Prasad, V.; Grove, M.

    2009-12-01

    Like other mass spectrometers, gas source instruments are very good at precisely measuring isotopic ratios but need to be calibrated with a standard to be accurate. The need for calibration arises due to the complicated ionization process which inefficiently and differentially creates ions from the various isotopes that make up the elemental gas. Calibration of the ionization process requires materials with well understood isotopic compositions as standards. Our project goal was to calibrate a noble gas (Noblesse) mass spectrometer with a purified air sample. Our sample obtained from Ocean Beach in San Francisco was under known temperature, pressure, volume, humidity. We corrected the pressure for humidity and used the ideal gas law to calculate the number of moles of argon gas. We then removed all active gasses using specialized equipment designed for this purpose at the United States Geological Survey. At the same time, we measured the volume ratios of various parts of the gas extraction line system associated with the Noblesse mass spectrometer. Using this data, we calculated how much Ar was transferred to the reservoir from the vacuum-sealed vial that contained the purified gas standard. Using similar measurements, we also calculated how much Ar was introduced into the extraction line from a pipette system and how much of this Ar was ultimately expanded into the Noblesse mass spectrometer. Based upon this information, it was possible to calibrate the argon sensitivity of the mass spectrometer. From a knowledge of the isotopic composition of air, it was also possible to characterize how ionized argon isotopes were fractionated during analysis. By repeatedly analyzing our standard we measured a 40Ar Sensitivity of 2.05 amps/bar and a 40Ar/36Ar ratio of 309.2 on the Faraday detector. In contrast, measurements carried out by ion counting using electron multipliers yield a value (296.8) which is much closer to the actual atmospheric 40Ar/36Ar value of 295.5.

  1. In-beam electron spectrometer used in conjunction with a gas-filled recoil separator

    Kankaanpaeae, H.; Butler, P.A.; Greenlees, P.T.; Bastin, J.E.; Herzberg, R.D.; Humphreys, R.D.; Jones, G.D.; Jones, P.; Julin, R.; Keenan, A.; Kettunen, H.; Leino, M.; Miettinen, L.; Page, T.; Rahkila, P.; Scholey, C.; Uusitalo, J.

    2004-01-01

    The conversion-electron spectrometer SACRED has been redesigned for use in conjunction with the RITU gas-filled recoil separator. The system allows in-beam recoil-decay-tagging (RDT) measurements of internal conversion electrons. The performance of the system using standard sources and in-beam is described

  2. Performance report for the low energy compact radiocarbon accelerator mass spectrometer at Uppsala University

    Salehpour, M., E-mail: mehran.salehpour@physics.uu.se [Department of Physics and Astronomy, Ion Physics, Applied Nuclear Physics Division, P.O. Box 516, SE-751 20 Uppsala (Sweden); Håkansson, K.; Possnert, G. [Department of Physics and Astronomy, Ion Physics, Applied Nuclear Physics Division, P.O. Box 516, SE-751 20 Uppsala (Sweden); Wacker, L.; Synal, H.-A. [Ion Physics, ETH Zurich, Otto-Stern-Weg 5, 8093 (Switzerland)

    2016-03-15

    A range of ion beam analysis activities are ongoing at Uppsala University, including Accelerator Mass Spectrometry (AMS). Various isotopes are used for AMS but the isotope with the widest variety of applications is radiocarbon. Up until recently, only the 5 MV Pelletron tandem accelerator had been used at our site for radiocarbon AMS, ordinarily using 12 MeV {sup 14,13,12}C{sup 3+} ions. Recently a new radiocarbon AMS system, the Green-MICADAS, developed at the ion physics group at ETH Zurich, was installed. The system has a number of outstanding features which will be described. The system operates at a terminal voltage of 175 kV and uses helium stripper gas, extracting singly charged carbon ions. The low- and high energy mass spectrometers in the system are stigmatic dipole permanent magnets (0.42 and 0.97 T) requiring no electrical power nor cooling water. The system measures both the {sup 14}C/{sup 12}C and the {sup 13}C/{sup 12}C ratios on-line. Performance of the system is presented for both standard mg samples as well as μg-sized samples.

  3. Performance report for the low energy compact radiocarbon accelerator mass spectrometer at Uppsala University

    Salehpour, M.; Håkansson, K.; Possnert, G.; Wacker, L.; Synal, H.-A.

    2016-03-01

    A range of ion beam analysis activities are ongoing at Uppsala University, including Accelerator Mass Spectrometry (AMS). Various isotopes are used for AMS but the isotope with the widest variety of applications is radiocarbon. Up until recently, only the 5 MV Pelletron tandem accelerator had been used at our site for radiocarbon AMS, ordinarily using 12 MeV 14,13,12C3+ ions. Recently a new radiocarbon AMS system, the Green-MICADAS, developed at the ion physics group at ETH Zurich, was installed. The system has a number of outstanding features which will be described. The system operates at a terminal voltage of 175 kV and uses helium stripper gas, extracting singly charged carbon ions. The low- and high energy mass spectrometers in the system are stigmatic dipole permanent magnets (0.42 and 0.97 T) requiring no electrical power nor cooling water. The system measures both the 14C/12C and the 13C/12C ratios on-line. Performance of the system is presented for both standard mg samples as well as μg-sized samples.

  4. Gas-phase ion-molecule reactions and high-pressure mass spectrometer, 1

    Hiraoka, Kenzo

    1977-01-01

    The reasons for the fact that the research in gas-phase ion-molecule reactions, to which wide interest is shown, have greatly contributed to the physical and chemical fields are that, first it is essential in understanding general phenomena concerning ions, second, it can furnish many unique informations in the dynamics of chemical reactions, and third, usefulness of '' chemical ionization'' methods has been established as its application to chemical analysis. In this review, the history and trend of studies and equipments in gas-phase ion-molecule reactions are surveyed. The survey includes the chemical ionization mass spectrometer for simultaneously measuring the positive and negative ions utilizing a quadrupole mass spectrometer presented by Hunt and others, flowing afterglow method derived from the flowing method which traces neutral chemical species mainly optically, ion cyclotron resonance mass spectrometer, trapped ion mass spectrometer and others. Number of reports referred to ion-molecule reactions issued during the last one year well exceeds the total number of reports concerning mass spectrometers presented before 1955. This truly shows how active the research and development are in this field. (Wakatsuki, Y.)

  5. Movable chromatemass-spectrometer for attestation of working places in oil-gas processing sector

    Nuriev, K.Z.; Kolesnikova, U.P.; Balayeva, A.A.

    2005-01-01

    Small capacity chromatomass-spectrometer (KhS) intended for defining chemical compound of the atmosphere weather in open and close locations for the purpose of attestation of working places in the oil gas production plants. Characteristics and parameters of all nodes of KhS, playing a certain part in realization of given device were given and based. Accounts and constructive parameters of concrete KhS and technical activities of developed device were actuated

  6. New gas-filled mode of the large-acceptance spectrometer VAMOS

    Schmitt, C.; Rejmund, M.; Navin, A.; Lecornu, B.; Jacquot, B.; France, G. de; Lemasson, A.; Shrivastava, A.; Greenlees, P.; Uusitalo, J.; Subotic, K.; Gaudefroy, L.; Theisen, Ch.; Sulignano, B.; Dorvaux, O.; Stuttge, L.

    2010-01-01

    A new gas-filled operation mode of the large-acceptance spectrometer VAMOS at GANIL is reported. A beam rejection factor greater than 10 10 is obtained for the 40 Ca+ 150 Sm system at 196 MeV. The unprecedented transmission efficiency for the evaporation residues produced in this reaction is estimated to be around 80% for αx n channels and above 95% for x ny p channels. A detailed study of the performance of the gas-filled VAMOS and future developments are discussed. This new operation mode opens avenues to explore the potential of fusion reactions in various kinematics.

  7. The SAGE spectrometer

    Pakarinen, J.; Papadakis, P. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Sorri, J.; Greenlees, P.T.; Jones, P.; Julin, R.; Konki, J.; Rahkila, P.; Sandzelius, M. [University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Herzberg, R.D.; Butler, P.A.; Cox, D.M.; Cresswell, J.R.; Mistry, A.; Page, R.D.; Parr, E.; Sampson, J.; Seddon, D.A.; Thornhill, J.; Wells, D. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); Coleman-Smith, P.J.; Lazarus, I.H.; Letts, S.C.; Pucknell, V.F.E.; Simpson, J. [STFC Daresbury Laboratory, Warrington (United Kingdom)

    2014-03-15

    The SAGE spectrometer has been constructed for in-beam nuclear structure studies. SAGE combines a Ge-detector array and an electron spectrometer for detection of γ-rays and internal conversion electrons, respectively, and allows simultaneous observation of both electrons and γ-rays emitted from excited nuclei. SAGE is set up in the Accelerator Laboratory of the University of Jyvaeskylae and works in conjunction with the RITU gas-filled recoil separator and the GREAT focal-plane spectrometer allowing the use of the recoil-decay tagging method. (orig.)

  8. The SAGE spectrometer

    Pakarinen, J.; Papadakis, P.; Sorri, J.; Greenlees, P.T.; Jones, P.; Julin, R.; Konki, J.; Rahkila, P.; Sandzelius, M.; Herzberg, R.D.; Butler, P.A.; Cox, D.M.; Cresswell, J.R.; Mistry, A.; Page, R.D.; Parr, E.; Sampson, J.; Seddon, D.A.; Thornhill, J.; Wells, D.; Coleman-Smith, P.J.; Lazarus, I.H.; Letts, S.C.; Pucknell, V.F.E.; Simpson, J.

    2014-01-01

    The SAGE spectrometer has been constructed for in-beam nuclear structure studies. SAGE combines a Ge-detector array and an electron spectrometer for detection of γ-rays and internal conversion electrons, respectively, and allows simultaneous observation of both electrons and γ-rays emitted from excited nuclei. SAGE is set up in the Accelerator Laboratory of the University of Jyvaeskylae and works in conjunction with the RITU gas-filled recoil separator and the GREAT focal-plane spectrometer allowing the use of the recoil-decay tagging method. (orig.)

  9. Online precision gas evaluation of the ATLAS Muon Spectrometer during LHC RUN1

    The ATLAS collaboration

    2014-01-01

    The ATLAS Muon Spectrometer, a six story structure embedded in a toroidal magnetic field, is constructed of nearly 1200 Monitored Drift Tube chambers (MDTs) containing 354,000 aluminum drift tubes. The operating gas is 93% Ar + 7% CO2 with a small amount of water vapor at a pressure of 3 bar. The momentum resolution required for the LHC physics (dp/p = 2% at 100 GeV) demands that MDT gas gas quality and the associated gas dependent calibrations be determined with a rapid feedback cycle. During the LHC Run 1 more than 2 billion liters of gas flowed through the detector at a rate 100,000 l/hr. Online evauation of MDT gas in real time and the associated contribution to the determination of the time-to-space functions was conducted by the dedicated Gas Monitor Chamber. We report on the operation and results of the GMC over the first three years of LHC running. During this period, the GMC has operated with a nearly 100% duty cycle, providing hourly measurements of the MDT drift times with 1 ns precision, correspon...

  10. Online precision gas evaluation of the ATLAS Muon Spectrometer during LHC Run1

    AUTHOR|(CDS)2092735; The ATLAS collaboration

    2016-01-01

    The ATLAS Muon Spectrometer, a six story structure embedded in a toroidal magnetic field, is constructed of nearly 1200 Monitored Drift Tube chambers (MDTs) containing 354,000 aluminum drift tubes. The operating gas is 93% Ar + 7% CO${_2}$ with a small amount of water vapor at a pressure of 3 bar. The momentum resolution required for ATLAS physics demands that MDT gas quality and the associated gas dependent calibrations be determined with a rapid feedback cycle. During the LHC Run1, more than 2 billion liters of gas flowed through the detector at a rate 100,000 l/hr. Online evaluation of MDT gas in real time and the associated contribution to the determination of the time-to-space functions was conducted by the dedicated Gas Monitor Chamber (GMC). We report on the operation and results of the GMC over the first three years of LHC running. During this period, the GMC has operated with a nearly 100% duty cycle, providing hourly measurements of the MDT drift times with 1 ns precision, corresponding to minute ch...

  11. Correlation spectrometer

    Sinclair, Michael B [Albuquerque, NM; Pfeifer, Kent B [Los Lunas, NM; Flemming, Jeb H [Albuquerque, NM; Jones, Gary D [Tijeras, NM; Tigges, Chris P [Albuquerque, NM

    2010-04-13

    A correlation spectrometer can detect a large number of gaseous compounds, or chemical species, with a species-specific mask wheel. In this mode, the spectrometer is optimized for the direct measurement of individual target compounds. Additionally, the spectrometer can measure the transmission spectrum from a given sample of gas. In this mode, infrared light is passed through a gas sample and the infrared transmission signature of the gasses present is recorded and measured using Hadamard encoding techniques. The spectrometer can detect the transmission or emission spectra in any system where multiple species are present in a generally known volume.

  12. A highly polarized hydrogen/deuterium internal gas target embedded in a toroidal magnetic spectrometer

    Cheever, D.; Ihloff, E.; Kelsey, J.; Kolster, H.; Meitanis, N.; Milner, R.; Shinozaki, A.; Tsentalovich, E.; Zwart, T.; Ziskin, V.; Xiao, Y.; Zhang, C.

    2006-01-01

    A polarized hydrogen/deuterium internal gas target has been constructed and operated at the internal target region of the South Hall Ring (SHR) of the MIT-Bates Linear Accelerator Center to carry out measurements of spin-dependent electron scattering at 850MeV. The target used an Atomic Beam Source (ABS) to inject a flux of highly polarized atoms into a thin-walled, coated storage cell. The polarization of the electron beam was determined using a Compton laser backscattering polarimeter. The target polarization was determined using well-known nuclear reactions. The ABS and storage cell were embedded in the Bates Large Acceptance Toroidal Spectrometer (BLAST), which was used to detect scattered particles from the electron-target interactions. The target has been designed to rapidly (∼8h) switch operation from hydrogen to deuterium. Further, this target was the first to be operated inside a magnetic spectrometer in the presence of a magnetic field exceeding 2kG. An ABS intensity 2.5x10 16 at/s and a high polarization (∼70%) inside the storage cell have been achieved. The details of the target design and construction are described here and the performance over an 18 month period is reported

  13. Ground based THz Spectroscopy of Obscured Starbursts in the Early Universe enabled by the 2nd generation Redshift (z) & Early Universe Spectrometer (ZEUS-2)

    Vishwas, Amit; Stacey, Gordon; Nikola, Thomas; Ferkinhoff, Carl; Parshley, Stephen; Schoenwald, Justin; Lamarche, Cody James; Higdon, James; Higdon, Sarah; Brisbin, Drew; Güesten, Rolf; Weiss, Axel; Menten, Karl; Irwin, Kent; Cho, Hsiao-Mei; Niemack, Michael; Hilton, Gene; Hubmayr, Johannes; Amiri, Mandana; Halpern, Mark; Wiebe, Donald; Hasselfield, Matthew; Ade, Peter; Tucker, Carole

    2018-01-01

    Galaxies were surprisingly dusty in the early Universe, with more than half of the light emitted from stars being absorbed by dust within the system and re-radiated into far infrared (FIR, ~50-150μm) wavelengths. Dusty star forming galaxies (DSFGs) dominate the co-moving star formation rate density of the Universe that peaks around redshift, z~2, making it compelling to study them in rest frame FIR bands. From galaxies at z > 1, the FIR line emission from abundant ions like [O III], [C II] and [N II], are redshifted into the short sub-mm telluric windows. My thesis work is based on building and deploying the 2nd Generation Redshift (z) and Early Universe Spectrometer (ZEUS-2), a long-slit, echelle grating spectrometer optimized to study broad (Δv = 300km/s) spectral lines from galaxies in the 200-650µm telluric windows using TES bolometers. These far-IR lines being extinction free and major coolants of the gas heated by (young) massive stars, are powerful probes of the physical conditions of the gas and the stellar radiation field. I present results from our survey of the [O III] 88µm line in galaxies at redshift, z ~ 2.8 to 4.6, with ZEUS-2 at the Atacama Pathfinder Experiment (APEX) Telescope. To interpret our observations along with ancillary data from optical to radio facilities, we apply photoionization models for HII regions and Photo Dissociation Region (PDR) models and confirm that the galaxies host substantial ongoing obscured star formation. The presence of doubly ionized oxygen suggests hard radiation fields and hence, elevated ionization parameters that can only be accounted for by a large population of massive stars formed during the ongoing starburst, that contribute a large fraction of the infrared luminosity. This study highlights the use of FIR line emission to trace the assembly of current day massive galaxies, conditions of star formation and details of their stellar populations. The construction and operation of ZEUS-2 were funded by NSF ATI

  14. On the ability of the Viking gas chromatograph-mass spectrometer to detect organic matter.

    Biemann, Klaus

    2007-06-19

    A recent paper by Navarro-Gonzalez et al. [Navarro-Gonzalez R, Navarro KF, de la Rosa J, Iniguez E, Molina P, Miranda LD, Morales P, Cienfuegos E, Coll P, Raulin F, et al. (2006) Proc Natl Acad Sci USA 103:16089-16094] claims to show that the Viking GCMS (gas chromatograph-mass spectrometer) experiment, which carried out a search for organic matter at the surface of Mars in 1976, "may have been blind to low levels of organics." To rebut this assertion, the Viking experiment, test data, and results on Mars are reviewed, and the fallacies in the design, execution, and interpretation of the new experiments presented by Navarro-Gonzalez et al. are critically examined.

  15. A new time of flight mass spectrometer for absolute dissociative electron attachment cross-section measurements in gas phase

    Chakraborty, Dipayan; Nag, Pamir; Nandi, Dhananjay

    2018-02-01

    A new time of flight mass spectrometer (TOFMS) has been developed to study the absolute dissociative electron attachment (DEA) cross section using a relative flow technique of a wide variety of molecules in gas phase, ranging from simple diatomic to complex biomolecules. Unlike the Wiley-McLaren type TOFMS, here the total ion collection condition has been achieved without compromising the mass resolution by introducing a field free drift region after the lensing arrangement. The field free interaction region is provided for low energy electron molecule collision studies. The spectrometer can be used to study a wide range of masses (H- ion to few hundreds atomic mass unit). The mass resolution capability of the spectrometer has been checked experimentally by measuring the mass spectra of fragment anions arising from DEA to methanol. Overall performance of the spectrometer has been tested by measuring the absolute DEA cross section of the ground state SO2 molecule, and the results are satisfactory.

  16. Local thermal equilibrium and ideal gas Stephani universes

    Coll, Bartolomé; Ferrando, Joan Josep

    2004-01-01

    The Stephani universes that can be interpreted as an ideal gas evolving in local thermal equilibrium are determined. Five classes of thermodynamic schemes are admissible, which give rise to five classes of regular models and three classes of singular models. No Stephani universes exist representing an exact solution to a classical ideal gas (one for which the internal energy is proportional to the temperature). But some Stephani universes may approximate a classical ideal gas at first order i...

  17. Ferrographic and spectrometer oil analysis from a failed gas turbine engine

    Jones, W. R., Jr.

    1982-01-01

    An experimental gas turbine engine was destroyed as a result of the combustion of its titanium components. It was concluded that a severe surge may have caused interference between rotating and stationary compressor that either directly or indirectly ignited the titanium components. Several engine oil samples (before and after the failure) were analyzed with a Ferrograph, a plasma, an atomic absorption, and an emission spectrometer to see if this information would aid in the engine failure diagnosis. The analyses indicated that a lubrication system failure was not a causative factor in the engine failure. Neither an abnormal wear mechanism nor a high level of wear debris was detected in the engine oil sample taken just prior to the test in which the failure occurred. However, low concentrations (0.2 to 0.5 ppm) of titanium were evident in this sample and samples taken earlier. After the failure, higher titanium concentrations ( 2 ppm) were detected in oil samples taken from different engine locations. Ferrographic analysis indicated that most of the titanium was contained in spherical metallic debris after the failure. The oil analyses eliminated a lubrication system bearing or shaft seal failure as the cause of the engine failure.

  18. A compact high resolution ion mobility spectrometer for fast trace gas analysis.

    Kirk, Ansgar T; Allers, Maria; Cochems, Philipp; Langejuergen, Jens; Zimmermann, Stefan

    2013-09-21

    Drift tube ion mobility spectrometers (IMS) are widely used for fast trace gas detection in air, but portable compact systems are typically very limited in their resolving power. Decreasing the initial ion packet width improves the resolution, but is generally associated with a reduced signal-to-noise-ratio (SNR) due to the lower number of ions injected into the drift region. In this paper, we present a refined theory of IMS operation which employs a combined approach for the analysis of the ion drift and the subsequent amplification to predict both the resolution and the SNR of the measured ion current peak. This theoretical analysis shows that the SNR is not a function of the initial ion packet width, meaning that compact drift tube IMS with both very high resolution and extremely low limits of detection can be designed. Based on these implications, an optimized combination of a compact drift tube with a length of just 10 cm and a transimpedance amplifier has been constructed with a resolution of 183 measured for the positive reactant ion peak (RIP(+)), which is sufficient to e.g. separate the RIP(+) from the protonated acetone monomer, even though their drift times only differ by a factor of 1.007. Furthermore, the limits of detection (LODs) for acetone are 180 pptv within 1 s of averaging time and 580 pptv within only 100 ms.

  19. Direct coupling of a dense (supercritical) gas chromatograph to a mass spectrometer using a supersonic molecular beam interface

    Randall, L.G.; Wahrhaftig, A.L.

    1981-01-01

    A detecting mass spectrometer has been successfully coupled to a dense gas (supercritical fluid) chromatograph to produce an instrument (DGC/MS) that may be an alternative to high performance liquid chromatograph/mass spectrometer instruments (HPLC/MS) and gas chromatograph/mass spectrometer instruments (GC/MS) for analysis of involatile and/or thermally labile compounds. The mobile phase in DGC is a gas held at temperatures above the critical temperature and at pressures sufficient to obtain nearly liquid-like densities. DGC combines advantages of GC and HPLC: rapid separations, moderate operating temperatures, and analysis of involatile compounds. An advantage unique to DGC is the solvent power dependence upon pressure. While several groups have studied DGC, its development has been limited by the lack of a sensitive and selective detector. Hence, work has been directed towards the design and construction of a DGC/MS resulting in a trial instrument capable of chromatographic pressures of at least 300 atm and temperatures from 10 0 to 60 0 C. The DGC/MS coupling has been accomplished by the use of a supersonic molecular beam interface. This application of molecular beam formation appears to be unique in its requirements of a large pressure ratio (approx.10 8 ), low flow rates, and low final pressures. The authors outline characteristics of supersonic jets and molecular beams pertinent to the design of such an instrument. The interface which uses pumping speeds of 2400 and 1200 l/s in the beam forming chambers is described in detail, while the other components: the detecting mass spectrometer, the dense gas supply, and the DGC: are briefly described. Preliminary work with this instrument has established the feasibility of DGC/MS as an analytical technique and further development is recommended

  20. Analysis of the fatty acid composition of taraxicuum officinale flowers oil by gas chromatography mass spectrometer

    Hussain, I.; Ullah, R.

    2013-01-01

    Taraxicum officinale, is a highly valuable medicinal plant. The roots is an important herbal drug, having long been used on the continent as a remedy for liver complaints. Keeping in view the importance and wide applications in the pharmaceutical industries, the present study was therefore aimed to analyze the chemical constituents of the flowers of T. officinale. The T. officinale flowers oil constituents of methyl ester derivatives of fatty acids were analyzed applying gas chromatography coupled to mass spectrometer. The results obtained showed the presence of both containing the saturated as well as unsaturated fatty acids in T. officinale flower oils. A total of 19 different components were identified and quantified. The concentration level of Methyl ester of Lenolenic acid was found very effective in concentration 3.33%, among the identified analytes of interest. In addition, the level of other chemical constituents of methyl ester of palmitic acid 3.11%, myristic acid 1.87, linolenic acids 1.67%, stearic acid 0.97 were found. The concentration level of the rest of identified fatty acids analytes were below 1%. Thus the results obtained from the current initiative is very promising due to the presence of high percentage of valuable analytes concentrations recorded in the fatty acid of T. officinale flower oil. Thus due to the presence of highly important analytes which have increased their importance for consumption in the pharmaceuticals as well as its applications in the new formulations for different skin, cosmetics and health purposes and for use by local practioners. The study will also provide a scientific database line. (author)

  1. Onsite well screening with a transportable gas chromatography/mass spectrometer system

    Rossabi, J.; Eckenrode, B.A.; Owens, B.

    1992-01-01

    The number of hazardous waste site operations continue to multiply. The requirements for efficient chemical assessment and monitoring of these sites become more stringent daily. As more samples are required, the time required for cleanup operations also increases and may make analytical costs prohibitive. Thus improvements in operation efficiency and reduction of cost in evaluating specific sites to minimize or eliminate their toxic effects on the surrounding environment are critical. For many years a formal policy did not exist for the disposal of waste solvents and other chemicals, thus many of these compounds were disposed of ensite. So long as these materials were contained onsite they were not considered to pose a threat to the surrounding environment. We have since determined that many of these compounds found their way into the groundwater. Contaminants such as trichloroethylene and perchloroethylene, which were heavily used for cleaning and degreasing purposes, must be monitored. Groundwater wells can be used to define the location and extent of the migration of any contaminant plume and aid in the determination of required cleanup. The major problem is that monitoring of hundreds of wells may be necessary, requiring several hundred samples on a quarterly basis to characterize the degree and extent of any contamination. Onsite analysis of monitoring wells for this characterization of waste operations could provide time savings and significant cost reduction. Field analyses can provide the required analytical results quickly and at a reduced cost without compromising either sample integrity or data quality. By using onsite analytical instrumentation, such as a field-transportable gas chromatograph/mass spectrometer (GC/MS), screening analyses can be performed to eliminate retturning to the laboratory with meaningless samples. Onsite GC/MS will provide qualitative or semi-quantitative information that can significantly simplify subsequent laboratory analyses

  2. From carbon to actinides: A new universal 1MV accelerator mass spectrometer at ANSTO

    Wilcken, K.M., E-mail: klaus.wilcken@ansto.gov.au [Australian Nuclear Science & Technology Organisation, Sydney, New South Wales (Australia); Hotchkis, M.; Levchenko, V.; Fink, D. [Australian Nuclear Science & Technology Organisation, Sydney, New South Wales (Australia); Hauser, T.; Kitchen, R. [National Electrostatics Corporation, 7540 Graber Road, Middleton, WI 53562-0310 (United States)

    2015-10-15

    A new 1 MV NEC pelletron AMS system at ANSTO is presented. The spectrometer comprises large radius magnets for actinide measurements. A novel feature of the system is fast switching between isotopes both at low and high energy sections allowing measurements of up to 8 isotopes within a single sequence. Technical details and layout of the spectrometer is presented. Performance data for {sup 14}C, {sup 10}Be, {sup 26}Al and actinides demonstrate the system is ready for routine AMS measurements.

  3. From carbon to actinides: A new universal 1MV accelerator mass spectrometer at ANSTO

    Wilcken, K. M.; Hotchkis, M.; Levchenko, V.; Fink, D.; Hauser, T.; Kitchen, R.

    2015-10-01

    A new 1 MV NEC pelletron AMS system at ANSTO is presented. The spectrometer comprises large radius magnets for actinide measurements. A novel feature of the system is fast switching between isotopes both at low and high energy sections allowing measurements of up to 8 isotopes within a single sequence. Technical details and layout of the spectrometer is presented. Performance data for 14C, 10Be, 26Al and actinides demonstrate the system is ready for routine AMS measurements.

  4. Massive Fermi gas in the expanding universe

    Trautner, Andreas, E-mail: atrautner@uni-bonn.de [Bethe Center for Theoretical Physics and Physikalisches Institut der Universität Bonn, Nussallee 12, 53115 Bonn (Germany)

    2017-03-01

    The behavior of a decoupled ideal Fermi gas in a homogeneously expanding three-dimensional volume is investigated, starting from an equilibrium spectrum. In case the gas is massless and/or completely degenerate, the spectrum of the gas can be described by an effective temperature and/or an effective chemical potential, both of which scale down with the volume expansion. In contrast, the spectrum of a decoupled massive and non-degenerate gas can only be described by an effective temperature if there are strong enough self-interactions such as to maintain an equilibrium distribution. Assuming perpetual equilibration, we study a decoupled gas which is relativistic at decoupling and then is red-shifted until it becomes non-relativistic. We find expressions for the effective temperature and effective chemical potential which allow us to calculate the final spectrum for arbitrary initial conditions. This calculation is enabled by a new expansion of the Fermi-Dirac integral, which is for our purpose superior to the well-known Sommerfeld expansion. We also compute the behavior of the phase space density under expansion and compare it to the case of real temperature and real chemical potential. Using our results for the degenerate case, we also obtain the mean relic velocity of the recently proposed non-thermal cosmic neutrino background.

  5. The motion of an isolated gas group in expanding universe

    Zhang Banggu

    1993-01-01

    The contraction of an isolated gas group in the expanding universe has been discussed. It is found that in addition to the contracted conditions of the static isolated gas group, the initial gas group is straticulate statistical uniform and the initial radius is larger than a critical value D γ -1 , the contracted conditions of expanding case also include that the Hubble constant H is smaller than a constant D t

  6. Interfacing a gas proportional counter with a mass spectrometer: Simultaneous display of GC/MS and radiocarbon data

    Peterson, G.S.; Laemmerhirt, D.F.; Weaver, A.

    1985-01-01

    To facilitate the location of pesticides and monitor their metabolism in environmental and biological systems, carbon-14 labelling of the parent compound is used. Detection of the radiolabel is achieved using a gas proportional counter, while identification of the labelled components is most easily accomplished with mass spectrometry. However, when these two operations are performed separately, correlation of the information is awkward, at best. Since each is a destructive detector, simultaneous monitoring of the outposts requires an effluent splitter. The complete system consists of a variable splitter, which allows control of the ratio of the GC effluent to the two instruments, and signal processing circuitry for simultaneous recording and storage of radiocarbon and mass spectral data. Modifications to a Finnigan GC/MS and Gas Proportional Counter included a high temperature GC effluent splitter with glass-lined connecting tubing, and a data interface, including analog to digital and serial to parallel conversions with optical isolation between the gas proportional counter and the computer. The splitter restricted the flow to the mass spectrometer, preventing flow completely in the closed position. The split was adjusted to maximize flow to the mass spectrometer using the vacuum as a rough guide (1.0 x 10 -5 torr in EI, 7.5 x 10 -5 torr in CI). A heated transfer line between the transfer oven and gas proportional counter prevented condensation of eluting components prior to radiocarbon detection

  7. The University of Colorado OSO-8 spectrometer experiment. I - Introduction and optical design considerations

    Bruner, E. C., Jr.

    1977-01-01

    The optical design of the high-resolution ultraviolet spectrometer prepared for the OSO-8 spacecraft is discussed. The instrument is a conventional 1 m Ebert-Fastie spectrometer fed by a Cassegrainian telescope. The instrument operates in the spectral range 1200-2000 A with spectral resolution of order 0.02 A. Spatial resolution is about 2.5 arcsec normal to the direction of the slit and is selectable from about 3 arcsec to 15 arcmin along the direction of the slit. Time resolution for the single spectrometer channel is selectable according to the needs of an individual observation and is limited to a maximum sampling rate of 40 ms per data point. The instrument is controlled by an internal general purpose computer.

  8. The second-generation z (redshift) and early universe spectrometer. I. First-light observation of a highly lensed local-ulirg analog at high-z

    Ferkinhoff, Carl; Brisbin, Drew; Parshley, Stephen; Nikola, Thomas; Stacey, Gordon J.; Schoenwald, Justin; Riechers, Dominik [Department of Astronomy, Cornell University, Ithaca, NY 14853 (United States); Higdon, James L.; Higdon, Sarah J. U. [Department of Physics, Georgia Southern University, Statesboro, GA 30460 (United States); Verma, Aprajita [Department of Physics, University of Oxford, Oxford, OX1 3RH (United Kingdom); Hailey-Dunsheath, Steven [California Institute of Technology, Pasadena, CA 91125 (United States); Menten, Karl M.; Güsten, Rolf; Weiß, Axel [Max-Planck-Institut für Radioastronomie, Auf dem Hügel 69, D-53121 Bonn (Germany); Irwin, Kent; Cho, Hsiao M. [NIST Boulder, Boulder, CO 80305 (United States); Niemack, Michael [Department of Physics, Cornell University, Ithaca, NY 14853 (United States); Halpern, Mark; Amiri, Mandana [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada); Hasselfield, Matthew, E-mail: carl.ferkinhoff@cornell.edu [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States); and others

    2014-01-10

    We recently commissioned our new spectrometer, the second-generation z(Redshift) and Early Universe Spectrometer (ZEUS-2) on the Atacama Pathfinder Experiment telescope. ZEUS-2 is a submillimeter grating spectrometer optimized for detecting the faint and broad lines from distant galaxies that are redshifted into the telluric windows from 200 to 850 μm. It uses a focal plane array of transition-edge sensed bolometers, the first use of these arrays for astrophysical spectroscopy. ZEUS-2 promises to be an important tool for studying galaxies in the years to come because of its synergy with Atacama Large Millimeter Array and its capabilities in the short submillimeter windows that are unique in the post-Herschel era. Here, we report on our first detection of the [C II] 158 μm line with ZEUS-2. We detect the line at z ∼ 1.8 from H-ATLAS J091043.1–000322 with a line flux of (6.44 ± 0.42) × 10{sup –18} W m{sup –2}. Combined with its far-IR luminosity and a new Herschel-PACS detection of the [O I] 63 μm line, we model the line emission as coming from a photo-dissociation region with far-ultraviolet radiation field, G ∼ 2 × 10{sup 4} G {sub 0}, gas density, n ∼ 1 × 10{sup 3} cm{sup –3} and size between ∼0.4 and 1 kpc. On the basis of this model, we conclude that H-ATLAS J091043.1–000322 is a high-redshift analog of a local ultra-luminous IR galaxy; i.e., it is likely the site of a compact starburst caused by a major merger. Further identification of these merging systems is important for constraining galaxy formation and evolution models.

  9. The Second-generation z (Redshift) and Early Universe Spectrometer. I. First-light Observation of a Highly Lensed Local-ulirg Analog at High-z

    Ferkinhoff, Carl; Brisbin, Drew; Parshley, Stephen; Nikola, Thomas; Stacey, Gordon J.; Schoenwald, Justin; Higdon, James L.; Higdon, Sarah J. U.; Verma, Aprajita; Riechers, Dominik; Hailey-Dunsheath, Steven; Menten, Karl M.; Güsten, Rolf; Weiß, Axel; Irwin, Kent; Cho, Hsiao M.; Niemack, Michael; Halpern, Mark; Amiri, Mandana; Hasselfield, Matthew; Wiebe, D. V.; Ade, Peter A. R.; Tucker, Carol E.

    2014-01-01

    We recently commissioned our new spectrometer, the second-generation z(Redshift) and Early Universe Spectrometer (ZEUS-2) on the Atacama Pathfinder Experiment telescope. ZEUS-2 is a submillimeter grating spectrometer optimized for detecting the faint and broad lines from distant galaxies that are redshifted into the telluric windows from 200 to 850 μm. It uses a focal plane array of transition-edge sensed bolometers, the first use of these arrays for astrophysical spectroscopy. ZEUS-2 promises to be an important tool for studying galaxies in the years to come because of its synergy with Atacama Large Millimeter Array and its capabilities in the short submillimeter windows that are unique in the post-Herschel era. Here, we report on our first detection of the [C II] 158 μm line with ZEUS-2. We detect the line at z ~ 1.8 from H-ATLAS J091043.1-000322 with a line flux of (6.44 ± 0.42) × 10-18 W m-2. Combined with its far-IR luminosity and a new Herschel-PACS detection of the [O I] 63 μm line, we model the line emission as coming from a photo-dissociation region with far-ultraviolet radiation field, G ~ 2 × 104 G 0, gas density, n ~ 1 × 103 cm-3 and size between ~0.4 and 1 kpc. On the basis of this model, we conclude that H-ATLAS J091043.1-000322 is a high-redshift analog of a local ultra-luminous IR galaxy; i.e., it is likely the site of a compact starburst caused by a major merger. Further identification of these merging systems is important for constraining galaxy formation and evolution models.

  10. The second-generation z (redshift) and early universe spectrometer. I. First-light observation of a highly lensed local-ulirg analog at high-z

    Ferkinhoff, Carl; Brisbin, Drew; Parshley, Stephen; Nikola, Thomas; Stacey, Gordon J.; Schoenwald, Justin; Riechers, Dominik; Higdon, James L.; Higdon, Sarah J. U.; Verma, Aprajita; Hailey-Dunsheath, Steven; Menten, Karl M.; Güsten, Rolf; Weiß, Axel; Irwin, Kent; Cho, Hsiao M.; Niemack, Michael; Halpern, Mark; Amiri, Mandana; Hasselfield, Matthew

    2014-01-01

    We recently commissioned our new spectrometer, the second-generation z(Redshift) and Early Universe Spectrometer (ZEUS-2) on the Atacama Pathfinder Experiment telescope. ZEUS-2 is a submillimeter grating spectrometer optimized for detecting the faint and broad lines from distant galaxies that are redshifted into the telluric windows from 200 to 850 μm. It uses a focal plane array of transition-edge sensed bolometers, the first use of these arrays for astrophysical spectroscopy. ZEUS-2 promises to be an important tool for studying galaxies in the years to come because of its synergy with Atacama Large Millimeter Array and its capabilities in the short submillimeter windows that are unique in the post-Herschel era. Here, we report on our first detection of the [C II] 158 μm line with ZEUS-2. We detect the line at z ∼ 1.8 from H-ATLAS J091043.1–000322 with a line flux of (6.44 ± 0.42) × 10 –18 W m –2 . Combined with its far-IR luminosity and a new Herschel-PACS detection of the [O I] 63 μm line, we model the line emission as coming from a photo-dissociation region with far-ultraviolet radiation field, G ∼ 2 × 10 4 G 0 , gas density, n ∼ 1 × 10 3 cm –3 and size between ∼0.4 and 1 kpc. On the basis of this model, we conclude that H-ATLAS J091043.1–000322 is a high-redshift analog of a local ultra-luminous IR galaxy; i.e., it is likely the site of a compact starburst caused by a major merger. Further identification of these merging systems is important for constraining galaxy formation and evolution models.

  11. In gas laser ionization and spectroscopy experiments at the Superconducting Separator Spectrometer (S3): Conceptual studies and preliminary design

    Ferrer, R.; Bastin, B.; Boilley, D.; Creemers, P.; Delahaye, P.; Liénard, E.; Fléchard, X.; Franchoo, S.; Ghys, L.; Huyse, M.; Kudryavtsev, Yu.; Lecesne, N.; Lu, H.; Lutton, F.; Mogilevskiy, E.; Pauwels, D.; Piot, J.; Radulov, D.; Rens, L.; Savajols, H.

    2013-01-01

    Highlights: • A setup to perform In-Gas Laser Ionization and Spectroscopy experiments at the Super Separator Spectrometer is presented. • The reported studies address important aspects necessary to applied the IGLIS technique to short-lived isotopes. • An R and D phase required to reach an enhanced spectral resolution will be carried out at KU Leuven. • High-sensitivity and enhanced-resolution laser spectroscopy studies will be possible with the IGLIS setup at S 3 . -- Abstract: The results of preparatory experiments and the preliminary designs of a new in-gas laser ionization and spectroscopy setup, to be coupled to the Super Separator Spectrometer S 3 of SPIRAL2-GANIL, are reported. Special attention is given to the development and tests to carry out a full implementation of the in-gas jet laser spectroscopy technique. Application of this novel technique to radioactive species will allow high-sensitivity and enhanced-resolution laser spectroscopy studies of ground- and excited-state properties of exotic nuclei

  12. Development of the 2nd generation z(Redshift) and early universe spectrometer & the study of far-IR fine structure emission in high-z galaxies

    Ferkinhoff, Carl

    The 2nd generation z (Redshift) and Early Universe Spectrometer (ZEUS-2), is a long-slit echelle-grating spectrometer (R~1000) for observations at submillimeter wavelengths from 200 to 850 microm. Its design is optimized for the detection of redshifted far-infrared spectral lines from galaxies in the early universe. Combining exquisite sensitivity, broad wavelength coverage, and large (˜2.5%) instantaneous bandwidth, ZEUS-2 is uniquely suited for studying galaxies between z˜0.2 and 5---spanning the peaks in both the star formation rate and number of AGN in the universe. ZEUS-2 saw first light at the Caltech Submillimeter Observatory (CSO) in the Spring of 2012 and was commissioned on the Atacama Pathfinder Experiment (APEX) in November 2012. Here we detail the design and performance of ZEUS-2, first however we discuss important science results that are examples of the science enabled by ZEUS-2. Using the first generation z (Redshift) and Early Universe Spectrometer (ZEUS-1) we made the first high-z detections of the [NII] 122 microm and [OIII] 88 microm lines. We detect these lines from starburst galaxies between z ˜2.5 and 4 demonstrating the utility of these lines for characterizing the properties of early galaxies. Specifically we are able to determine the most massive star still on the main sequence, the number of those stars and a lower limit on the mass of ionized gas in the source. Next we present ZEUS-2's first science result. Using ZEUS-2 on APEX we have detected the [CII] 158 microm line from the z = 1.78 galaxy H-ATLAS J091043.1-000322 with a line flux of (6.44 +/- 0.42) ˜ 10-18 W m-2. Combined with its far-infrared luminosity and a new Herschel-PACS detection of the [OI] 63 microm line we are able to conclude that H-ATLAS J091043.1-000322 is a high redshift analogue of a local ultra-luminous infrared galaxy, i.e. it is likely the site of a compact starburst due to a major merger. This detection, combined with the ZEUS-1 observations of the [NII

  13. Universal energy-dispersive EXAFS spectrometer based on SR beam of `Kurchatovskij Institute` and scientific program of investigations; Universal`nyj ehnergodispersionnyj EXAFS-spektrometr v Natsional`nom tsentre sinkhrotronnogo izlucheniya (`Kurchatovskij institut`) i nauchnaya programma issledovanij

    Aksenov, V L; Ivanov, I N [Laboratory of Particle Physics, Joint Institute for Nuclear Research, Dubna (Russian Federation); Koval` chuk, M V [Institut Kristallografii, RAN, Moscow (Russian Federation); and others

    1997-12-31

    The scheme of the energy-dispersive EXAFS spectrometer is discussed. The spectrometer will be used for the solid state investigations on the Kurchatov Synchrotron Radiation Source KSRS. The main elements of the universal station are described, including the results of the positive-sensitive X-ray detector testing. The experimental investigations are presented which are supposed to be carried out with this EXAFS spectrometer. (author). 4 refs., 14 figs., 1 tab. Submitted to Poverkhnost`. Rentgenovskie, Sinkhrotronnye i Nejtronnye Issledovaniya.

  14. Spectrometer gun

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  15. The Atmospheric Chemistry Suite (ACS) of Three Spectrometers for the ExoMars 2016 Trace Gas Orbiter

    Korablev, O.; Montmessin, F.; Trokhimovskiy, A.; Fedorova, A. A.; Shakun, A. V.; Grigoriev, A. V.; Moshkin, B. E.; Ignatiev, N. I.; Forget, F.; Lefèvre, F.; Anufreychik, K.; Dzuban, I.; Ivanov, Y. S.; Kalinnikov, Y. K.; Kozlova, T. O.; Kungurov, A.; Makarov, V.; Martynovich, F.; Maslov, I.; Merzlyakov, D.; Moiseev, P. P.; Nikolskiy, Y.; Patrakeev, A.; Patsaev, D.; Santos-Skripko, A.; Sazonov, O.; Semena, N.; Semenov, A.; Shashkin, V.; Sidorov, A.; Stepanov, A. V.; Stupin, I.; Timonin, D.; Titov, A. Y.; Viktorov, A.; Zharkov, A.; Altieri, F.; Arnold, G.; Belyaev, D. A.; Bertaux, J. L.; Betsis, D. S.; Duxbury, N.; Encrenaz, T.; Fouchet, T.; Gérard, J.-C.; Grassi, D.; Guerlet, S.; Hartogh, P.; Kasaba, Y.; Khatuntsev, I.; Krasnopolsky, V. A.; Kuzmin, R. O.; Lellouch, E.; Lopez-Valverde, M. A.; Luginin, M.; Määttänen, A.; Marcq, E.; Martin Torres, J.; Medvedev, A. S.; Millour, E.; Olsen, K. S.; Patel, M. R.; Quantin-Nataf, C.; Rodin, A. V.; Shematovich, V. I.; Thomas, I.; Thomas, N.; Vazquez, L.; Vincendon, M.; Wilquet, V.; Wilson, C. F.; Zasova, L. V.; Zelenyi, L. M.; Zorzano, M. P.

    2018-02-01

    The Atmospheric Chemistry Suite (ACS) package is an element of the Russian contribution to the ESA-Roscosmos ExoMars 2016 Trace Gas Orbiter (TGO) mission. ACS consists of three separate infrared spectrometers, sharing common mechanical, electrical, and thermal interfaces. This ensemble of spectrometers has been designed and developed in response to the Trace Gas Orbiter mission objectives that specifically address the requirement of high sensitivity instruments to enable the unambiguous detection of trace gases of potential geophysical or biological interest. For this reason, ACS embarks a set of instruments achieving simultaneously very high accuracy (ppt level), very high resolving power (>10,000) and large spectral coverage (0.7 to 17 μm—the visible to thermal infrared range). The near-infrared (NIR) channel is a versatile spectrometer covering the 0.7-1.6 μm spectral range with a resolving power of ˜20,000. NIR employs the combination of an echelle grating with an AOTF (Acousto-Optical Tunable Filter) as diffraction order selector. This channel will be mainly operated in solar occultation and nadir, and can also perform limb observations. The scientific goals of NIR are the measurements of water vapor, aerosols, and dayside or night side airglows. The mid-infrared (MIR) channel is a cross-dispersion echelle instrument dedicated to solar occultation measurements in the 2.2-4.4 μm range. MIR achieves a resolving power of >50,000. It has been designed to accomplish the most sensitive measurements ever of the trace gases present in the Martian atmosphere. The thermal-infrared channel (TIRVIM) is a 2-inch double pendulum Fourier-transform spectrometer encompassing the spectral range of 1.7-17 μm with apodized resolution varying from 0.2 to 1.3 cm-1. TIRVIM is primarily dedicated to profiling temperature from the surface up to ˜60 km and to monitor aerosol abundance in nadir. TIRVIM also has a limb and solar occultation capability. The technical concept of

  16. Gas-cooled reactor application for a university campus

    Colak, Ue.; Kadiroghlu, O.K.; Soekmen, C.N.; Schmitt, H.

    1991-01-01

    Large urban areas with unfavourable topographic and meteorological conditions suffer severe air pollution during the winter months. Use of low grade lignites, imported higher quality coal or imported fuel oil are the sources of air pollution in the form of sulphur dioxide, fly ash and soot. Large housing complexes or old and historical locations within the city are in need of pollution free centralized district heating systems. Natural gas imported from the Soviet Union is a solution for this problem. Lack of gas distribution network for high pressure gas within the city is the main bottle-neck for the heating systems utilizing natural gas. Concern of the safety of flammable high pressure gas circulating within the city is another drawback for the natural gas heating systems. Nuclear district heating is an environmentally viable option worth looking into it. Localized urban nuclear heating is an interesting solution for large urban areas with old and historical character. The results of a feasibility study on the HGR application for the Hacettepe University presented here, summarizes the concept of gas-cooled heating reactors specially designed for urban centers. The inherently safe characteristics of the pebble bed heating reactor makes localized urban nuclear heating a viable alternative to other heat sources. An economical analysis of various heat sources with equal power levels is done for the Beytepe campus of Hacettepe University in Ankara. Under special boundary conditions, the price for heat generation can be much lower for nuclear heating with GHR 20 than for hard coal or fuel oil. It is also possible that if the price escalation rate for natural gas exceeds 3%, then nuclear heating with GHR can be more competitive. It is concluded that the nuclear heating of Beytepe campus with a GHR 20 is feasible and economical. (author) 3 figs., 5 refs

  17. The University of Colorado OSO-8 spectrometer experiment. IV - Mission operations

    Hansen, E. R.; Bruner, E. C., Jr.

    1979-01-01

    The remote operation of two high-resolution ultraviolet spectrometers on the OSO-8 satellite is discussed. Mission operations enabled scientific observers to plan observations based on current solar data, interact with the observing program using real- or near real-time data and commands, evaluate quick-look instrument data, and analyze the observations for publication. During routine operations, experiments were planned a day prior to their execution, and the data from these experiments received a day later. When a shorter turnaround was required, a real-time mode was available. Here, the real-time data and command links into the remote control center were used to evaluate experiment operation and make satellite pointing or instrument configuration changes with a 1-90 minute turnaround.

  18. LAVA Subsystem Integration and Testing for the RESOLVE Payload of the Resource Prospector Mission: Mass Spectrometers and Gas Chromatography

    Coan, Mary R.; Stewart, Elaine M.

    2015-01-01

    The Regolith and Environment Science & Oxygen and Lunar Volatile Extraction (RESOLVE) payload is part of Resource Prospector (RP) along with a rover and a lander that are expected to launch in 2020. RP will identify volatile elements that may be combined and collected to be used for fuel, air, and water in order to enable deeper space exploration. The Resource Prospector mission is a key part of In-Situ Resource Utilization (ISRU). The demand for this method of utilizing resources at the site of exploration is increasing due to the cost of resupply missions and deep space exploration goals. The RESOLVE payload includes the Lunar Advanced Volatile Analysis (LAVA) subsystem. The main instrument used to identify the volatiles evolved from the lunar regolith is the Gas Chromatograph-Mass Spectrometer (GC-MS). LAVA analyzes the volatiles emitted from the Oxygen and Volatile Extraction Node (OVEN) Subsystem. The objective of OVEN is to obtain, weigh, heat and transfer evolved gases to LAVA through the connection between the two subsystems called the LOVEN line. This paper highlights the work completed during a ten week internship that involved the integration, testing, data analysis, and procedure documentation of two candidate mass spectrometers for the LAVA subsystem in order to aid in determining which model to use for flight. Additionally, the examination of data from the integrated Resource Prospector '15 (RP' 15) field test will be presented in order to characterize the amount of water detected from water doped regolith samples.

  19. Universal structure of a strongly interacting Fermi gas

    Kuhnle, Eva; Dyke, Paul; Hoinka, Sascha; Mark, Michael; Hu Hui; Liu Xiaji; Drummond, Peter; Hannaford, Peter; Vale, Chris, E-mail: cvale@swin.edu.au [ARC Centre of Excellence for Quantum Atom Optics, Swinburne University of Technology, Hawthorn 3122 (Australia)

    2011-01-10

    This paper presents studies of the universal properties of strongly interacting Fermi gases using Bragg spectroscopy. We focus on pair-correlations, their relationship to the contact C introduced by Tan, and their dependence on both the momentum and temperature. We show that short-range pair correlations obey a universal law, first derived by Tan through measurements of the static structure factor, which displays a universal scaling with the ratio of the contact to the momentum C/q. Bragg spectroscopy of ultracold {sup 6}Li atoms is employed to measure the structure factor for a wide range of momenta and interaction strengths, providing broad confirmation of this universal law. We show that calibrating our Bragg spectra using the f-sum rule leads to a dramatic improvement in the accuracy of the structure factor measurement. We also measure the temperature dependence of the contact in a unitary gas and compare our results to calculations based on a virial expansion.

  20. Rapid identification of pork for halal authentication using the electronic nose and gas chromatography mass spectrometer with headspace analyzer.

    Nurjuliana, M; Che Man, Y B; Mat Hashim, D; Mohamed, A K S

    2011-08-01

    The volatile compounds of pork, other meats and meat products were studied using an electronic nose and gas chromatography mass spectrometer with headspace analyzer (GCMS-HS) for halal verification. The zNose™ was successfully employed for identification and differentiation of pork and pork sausages from beef, mutton and chicken meats and sausages which were achieved using a visual odor pattern called VaporPrint™, derived from the frequency of the surface acoustic wave (SAW) detector of the electronic nose. GCMS-HS was employed to separate and analyze the headspace gasses from samples into peaks corresponding to individual compounds for the purpose of identification. Principal component analysis (PCA) was applied for data interpretation. Analysis by PCA was able to cluster and discriminate pork from other types of meats and sausages. It was shown that PCA could provide a good separation of the samples with 67% of the total variance accounted by PC1. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Low Power Consumption Lasers for Miniature Optical Spectrometers for Trace Gas Analysis

    Forouhar, S.; Frez, C.; Franz, K. J.; Ksendzov, A.; Qiu, Y.; Soibel, K. A.; Chen, J.; Hosoda, T.; Kipshidze, G.; Shterengas, L.; hide

    2011-01-01

    The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 micron wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micron and quantum cascade (QC) lasers in the 4.0-5.0 micron range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

  2. Potential for Measurement of Trace Volatile Organic Compounds in Closed Environments Using Gas Chromatograph/Differential Mobility Spectrometer

    Limero, Thomas; Cheng, Patti

    2007-01-01

    For nearly 3.5 years, the Volatile Organic Analyzer (VOA) has routinely analyzed the International Space Station (ISS) atmosphere for a target list of approximately 20 volatile organic compounds (VOCs). Additionally, an early prototype of the VOA collected data aboard submarines in two separate trials. Comparison of the data collected on ISS and submarines showed a surprising similarity in the atmospheres of the two environments. Furthermore, in both cases it was demonstrated that the VOA data can detect hardware issues unrelated to crew health. Finally, it was also clear in both operations that the VOA s size and resource consumption were major disadvantages that would restrict its use in the future. The VOA showed the value of measuring VOCs in closed environments, but it had to be shrunk if it was to be considered for future operations in these environments that are characterized by cramped spaces and limited resources. The Sionex Microanalyzer is a fraction of the VOA s size and this instrument seems capable of maintaining or improving upon the analytical performance of the VOA. The two design improvements that led to a smaller, less complex instrument are the Microanalyzer s use of recirculated air as the gas chromatograph s carrier gas and a micromachined detector. Although the VOA s ion mobility spectrometer and the Microanalyzer s differential mobility spectrometer (DMS) are related detector technologies, the DMS was more amenable to micromachining. This paper will present data from the initial assessment of the Microanalyzer. The instrument was challenged with mixtures that simulated the VOCs typically detected in closed-environment atmospheres.

  3. FAST Mapping of Diffuse HI Gas in the Local Universe

    Zhu, M.; Pisano, D. J.; Ai, M.; Jiao, Q.

    2016-02-01

    We propose to use the Five hundred meter Aperture Spherical radio Telescope (FAST) to map the diffuse intergalactic HI gas in the local universe at column densities of NHI=1018 cm-2 and below. The major science goal is to study gas accretion during galaxy evolution, and trace cosmic web features in the local universe. We disuss the technical feasibilty of such a deep survey, and have conducted test observations with the Arecibo 305 m telescope. Our preliminary results shows that, with about a few thousand hours of observing time, FAST will be able to map several hundred square degree regions at 1 σ of NHI=2×1017 cm-2 level out to a distance of 5-10 Mpc, and with a volume 1000 larger than that of the Local Group.

  4. Construction and simulation of a multi-reflection time-of-flight mass spectrometer at the University of Notre Dame

    Schultz, B.E., E-mail: bschult4@nd.edu; Kelly, J.M.; Nicoloff, C.; Long, J.; Ryan, S.; Brodeur, M.

    2016-06-01

    One of the most significant problems in the production of rare isotopes is the simultaneous production of contaminants, often time isobaric. Thus, a high-resolution beam purification method is required which needs to be compatible with both the low yield and short half-life of the desired radionuclide. A multi-reflection time-of-flight mass spectrometer meets all these criteria, in addition to boasting a smaller footprint relative to traditional separator dipole magnets. Such a device is currently under construction at the University of Notre Dame and is intended to be coupled to the IG-ISOL source of the planned cyclotron facility. The motivation and conceptual design are presented, as well as the status of simulations to determine the feasibility of using a Bradbury–Nielsen gate for bunching ion beams during initial system testing.

  5. Gas laser spectrometer for nuclear investigation at nucleonic stability limit. (project)

    Myshinskij, G.V.

    1989-01-01

    It is proposed to obtain the atomic beam of the proton-rich and neutron-rich nuclides with half-lives of up to 1 ms, by using the gas-jet technique. Subsequently their properties are investigated using the methods of laser resonance ionization and nuclear spectroscopy. 8 refs.; 4 figs

  6. Low Power Consumption Laser for Next Generation Miniature Optical Spectrometers for Trace Gas Analysis

    Forouhar, S.; Frez, C.; Franz, K. J.; Ksendzov, A.; Qiu, Y.; Soibel, K. A.; Chen, J.; Hosoda, T.; Kipshidze, G.; Shterengas, L.; hide

    2011-01-01

    The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 mu m wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 mu m and quantum cascade (QC) lasers in the 4.0-5.0 mu m range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft

  7. Warm and cold molecular gas conditions modelled in 87 galaxies observed by the Herschel SPIRE Fourier transform spectrometer

    Kamenetzky, J.; Rangwala, N.; Glenn, J.

    2017-11-01

    We have conducted two-component, non-local thermodynamic equilibrium modelling of the CO lines from J = 1-0 through J = 13-12 in 87 galaxies observed by the Herschel SPIRE Fourier Transform Spectrometer (FTS). We find the average pressure of the cold molecular gas, traced especially by CO J = 1-0, is ˜105.0±0.5 K cm-3. The mid- to high-J lines of CO trace higher pressure gas at 106.5 ± 0.6 K cm-3; this pressure is slightly correlated with LFIR. Two components are often necessary to accurately fit the Spectral Line Energy Distributions; a one-component fit often underestimates the flux of carbon monoxide (CO) J = 1-0 and the mass. If low-J lines are not included, mass is underestimated by an order of magnitude. Even when modelling the low-J lines alone or using an αCO conversion factor, the mass should be considered to be uncertain to a factor of at least 0.4 dex, and the vast majority of the CO luminosity will be missed (median, 65 per cent). We find a very large spread in our derived values of αCO, though they do not have a discernible trend with LFIR; the best fit is a constant 0.7 M⊙ (K km s- 1 pc2)-1, with a standard deviation of 0.36 dex, and a range of 0.3-1.6 M⊙ (K km s- 1 pc2)-1. We find average molecular gas depletion times (τdep) of 108 yr that decrease with increasing star formation rate. Finally, we note that the J = 11-10/J = 1-0 line flux ratio is diagnostic of the warm component pressure, and discuss the implications of this comprehensive study of SPIRE FTS extragalactic spectra for future study post-Herschel.

  8. Development of Tandem, Double-Focusing, Electron Impact, Gas Source Mass Spectrometer for Measurement of Rare Double-Substituted Isotoplogues in Geochemistry

    Young, Edward D. [University of California, Los Angeles, CA (United States)

    2015-07-30

    This project culminated in construction and delivery of the world’s first large-radius gas-source isotope ratio mass spectrometer that permits unparalleled analyses of the stable isotopic composition of methane gas. The instrument, referred to as the “Panorama” and installed at UCLA in March 2015, can now be used to determine the relative abundances of rare isotopic species of methane that serve as tracers of temperature of formation and/or subsequent processing of gas. With this technology we can begin to delineate different sources and sinks of methane isotopically in ways not possible until now.

  9. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  10. Galaxies and gas in a cold dark matter universe

    Katz, Neal; Hernquist, Lars; Weinberg, David H.

    1992-01-01

    We use a combined gravity/hydrodynamics code to simulate the formation of structure in a random 22 Mpc cube of a cold dark matter universe. Adiabatic compression and shocks heat much of the gas to temperatures of 10 exp 6 - 10 exp 7 K, but a fraction of the gas cools radiatively to about 10 exp 4 K and condenses into discrete, highly overdense lumps. We identify these lumps with galaxies. The high-mass end of their baryonic mass function fits the form of the observed galaxy luminosity function. They retain independent identities after their dark halos merge, so gravitational clustering produces groups of galaxies embedded in relatively smooth envelopes of hot gas and dark matter. The galaxy correlation function is approximately an r exp -2.1 power law from separations of 35 kpc to 7 Mpc. Galaxy fluctuations are biased relative to dark matter fluctuations by a factor b about 1.5. We find no significant 'velocity bias' between galaxies and dark matter particles. However, virial analysis of the simulation's richest group leads to an estimated Omega of about 0.3, even though the simulation adopts Omega = 1.

  11. Environmental Technology Verification Report. Field Portable Gas Chromatograph/Mass Spectrometer. Viking Instruments Corporation SpectraTrak (Trademark) 672

    Enfield, Wayne

    1997-01-01

    .... This self-contained, field transportable system, whose design has been adapted from laboratory technology, uses a contained, chromatographic column and accompanying mass spectrometer to provide...

  12. A gamma scintillation spectrometer

    Symbalisty, S

    1952-07-01

    A scintillation type gamma ray spectrometer employing coincidence counting, designed and built at the Physics Department of the University of Western Ontario is described. The spectrometer is composed of two anthracene and photomultiplier radiation detectors, two pulse analyzing channels, a coincidence stage, three scalers and a high voltage stabilized supply. A preliminary experiment to test the operation of the spectrometer was performed and the results of this test are presented. (author)

  13. Horizontal Ampoule Growth and Characterization of Mercuric Iodide at Controlled Gas Pressures for X-Ray and Gamma Ray Spectrometers

    Douglas, S.; McGregor Elsa; Ariesanti Bridget Corcoran

    2004-01-01

    The project developed a new method for producing high quality mercuric iodide crystals of x-ray and gamma spectrometers. Included are characterization of mercuric iodide crystal properties as a function of growth environment and fabrication and demonstration of room-temperature-operated high-resolution mercuric iodide spectrometers

  14. A STUDY ON CARBON ISOTOPE OF CO2 AND CH4 IN WESTERN DIENG PLATEU BY GAS CHROMATOGRAPHY- ISOTOPE RATIO MASS SPECTROMETER (GC-IRMS

    Hanik Humaida

    2010-06-01

    Full Text Available The carbon isotope can be used to evaluate volcanism phenomenon of volcano. The study of carbon isotope of CO2 and CH4 was carried out in western Dieng Plateau by mass-spectrometer. Before analysis, sampel was separated by gas chromatography using a Porapak-Q column and a FID (Flame Ionization Detector detector. The gas was oxidized by copper oxide at 850oC before being ionized in mass-spectrometer for isotope analysis. The CO2 content in Candradimuka crater (-4.10 O/OO, indicated that the gas may be as volcanic gas. The other CO2 from Sumber and western Gua Jimat, had isotope value  of -10.05 and -12.07 O/OO, respectively, indicating contamination from crustal and subduction material. The carbon isotope of CH4 gas from Pancasan village was -63.42 O/OO, that may be categorized as biogenic gas.   Keywords: isotope, CO2, CH4, Dieng.

  15. Assessment of a combined gas chromatography mass spectrometer sensor (GC-MSS) system for detecting biologically relevant volatile compounds (VCs).

    Gould, Oliver; Wieczorek, Tomas; de Lacy Costello, Ben P J; Persad, Raj; Ratcliffe, Norman

    2017-09-26

    There have been a number of studies in which metal oxide sensors (MOS) have replaced conventional analytical detectors in gas chromatography systems. However, despite the use of these instruments in a range of applications including breath research the sensor responses (i.e. resistance changes w.r.t. concentration of VCs) remain largely unreported. This paper addresses that issue by comparing the response of a metal oxide sensor directly with a mass spectrometer (MS), whereby both detectors are interfaced to the same GC column using an s-swafer. It was demonstrated that the sensitivity of an in-house fabricated ZnO/ SnO2 thick film MOS was superior to a modern MS for the detection of a wide range of volatile compounds (VCs) of different functionalities and masses. Better techniques for detection and quantification of these VCs is valuable, as many of these compounds are commonly reported throughout the scientific literature. This is also the first published report of a combined GC-MS sensor system. These 2 different detector technologies when combined, should enhance discriminatory abilities to aid disease diagnoses using volatiles from e.g. breath, and bodily fluids. 29 chemical standards have been tested using solid phase micro-extraction; 25 of these compounds are found on human breath. In all but 2 instances the sensor exhibited the same or superior limit of detection compared to the MS. 12 stool samples from healthy participants were analysed, the sensor detected, on average 1.6 peaks more per sample than the MS. Similarly analysing the headspace of E. coli broth cultures the sensor detected 6.9 more peaks per sample versus the MS. This greater sensitivity is primarily a function of the superior limits of detection of the metal oxide sensor. This shows that systems based on the combination of chromatography systems with solid state sensors shows promise for a range of applications. © 2017 IOP Publishing Ltd.

  16. GHGSat-D: Greenhouse gas plume imaging and quantification from space using a Fabry-Perot imaging spectrometer

    McKeever, J.; Durak, B. O. A.; Gains, D.; Jervis, D.; Varon, D. J.; Germain, S.; Sloan, J. J.

    2017-12-01

    GHGSat, Inc. has launched the first satellite designed to detect and quantify greenhouse gas emissions from individual industrial sites. Our demonstration satellite GHGSat-D or "CLAIRE" was launched in June 2016. It weighs less than 15 kg and its primary instrument is a miniaturized Fabry-Perot imaging spectrometer with spectral resolution on the order of 0.1 nm. The spectral bandpass is 1635-1670 nm, giving the instrument access to absorption bands of both CO2 and CH4. Our system is based on targeted observations rather than global coverage, and our spatial imaging resolution is a key differentiator. Specifically, with a ground sampling distance of effect of the Fabry-Perot resonator and the scrolling scene gives a different spectral sampling of each surface location in every image. While our data processing toolchain does not produce a conventional hyperspectral dataset, it does yield a spectral decomposition of the spatially resolved signal that is compared to a model that includes atmospheric radiative transfer and the instrument's pixel-dependent spectral responsivity. Our presentation will describe the instrument design, concept of operations and retrievals approach. We will also present images and results from GHGSat-D at different processing levels, including high-resolution column density retrievals. An observation of the degassing flux of methane from the outlet of a recently impounded hydroelectric reservoir will be shown as an example. Finally we discuss some performance limitations of GHGSat-D and our plans to overcome them as we update the instrument design for the next satellites.

  17. Field-portable Gas Chromatograph Mass Spectrometer (GC-MS) Unit for Semi-volatile Compound Analysis in Groundwater

    2011-09-01

    the need for a convective oven, greatly reducing the size and power consumption compared to standard GC systems. These modifications to the...spectrometer. In Harsh Environment Mass Spectrometry (HEMS) Conference; September 2007; Cocoa Beach, FL. Science Applications International Corporation

  18. Note: Buffer gas temperature inhomogeneities and design of drift-tube ion mobility spectrometers: Warnings for real-world applications by non-specialists

    Fernandez-Maestre, R.

    2017-09-01

    Ion mobility spectrometry (IMS) separates gas phase ions moving under an electric field according to their size-to-charge ratio. IMS is the method of choice to detect illegal drugs and explosives in customs and airports making accurate determination of reduced ion mobilities (K0) important for national security. An ion mobility spectrometer with electrospray ionization coupled to a quadrupole mass spectrometer was used to study uncertainties in buffer gas temperatures during mobility experiments. Differences up to 16°C were found in the buffer gas temperatures in different regions of the drift tube and up to 42°C between the buffer gas and the drift tube temperatures. The drift tube temperature is used as an approximation to the buffer gas temperature for the calculation of K0 because the buffer gas temperature is hard to measure. This is leading to uncertainties in the determination of K0 values. Inaccurate determination of K0 values yields false positives that delay the cargo and passengers in customs and airports. Therefore, recommendations are issued for building mobility tubes to assure a homogeneous temperature of the buffer gas. Because the temperature and other instrumental parameters are difficult to measure in IMS, chemical standards should always be used when calculating K0. The difference of 42°C between the drift tube and buffer gas temperatures found in these experiments produces a 10.5% error in the calculation of K0. This large inaccuracy in K0 shows the importance of a correct temperature measurement in IMS.

  19. A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

    Rieker, G. B.; Poehlmann, F. R.; Cappelli, M. A. [High Temperature Gasdynamics Laboratory, Stanford University, Stanford, California 94305 (United States)

    2013-07-15

    Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions.

  20. A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

    Rieker, G. B.; Poehlmann, F. R.; Cappelli, M. A.

    2013-01-01

    Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions

  1. A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

    Rieker, G. B.; Poehlmann, F. R.; Cappelli, M. A.

    2013-07-01

    Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions.

  2. A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode.

    Rieker, G B; Poehlmann, F R; Cappelli, M A

    2013-07-01

    Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions.

  3. Application of FIGAERO (Filter Inlet for Gases and AEROsol) coupled to a high resolution time of flight chemical ionization mass spectrometer to field and chamber organic aerosol: Implications for carboxylic acid formation and gas-particle partitioning from monoterpene oxidation

    Lopez-Hilfiker, F.; Mohr, C.; Ehn, M.; Rubach, F.; Mentel, T. F.; Kleist, E.; Wildt, J.; Thornton, J. A.

    2013-12-01

    We present measurements of a large suite of gas and particle phase carboxylic acid containing compounds made with a Filter Inlet for Gas and AEROsol (FIGAERO) coupled to a high resolution time of flight chemical ionization mass spectrometer (HR-ToF-CIMS) developed at the University of Washington. A prototype operated with acetate negative ion proton transfer chemistry was deployed on the Julich Plant Atmosphere Chamber to study a-pinene oxidation, and a modified version was deployed at the SMEAR II forest station in Hyytiälä, Finland and SOAS, in Brent Alabama. We focus here on results from JPAC and Hyytiälä, where we utilized the same ionization method most selective towards carboxylic acids. In all locations, 100's of organic acid compounds were observed in the gas and particles and many of the same composition acids detected in the gas-phase were detected in the particles upon temperature programmed thermal desorption. Particulate organics detected by FIGAERO are highly correlated with organic aerosol mass measured by an AMS, providing additional volatility and molecular level information about collected aerosol. The fraction of a given compound measured in the particle phase follows expected trends with elemental composition, but many compounds would not be well described by an absorptive partitioning model assuming unity activity coefficients. Moreover the detailed structure in the thermal desorption signals reveals a contribution from thermal decomposition of large molecular weight organics and or oligomers with implications for partitioning measurements and model validation

  4. Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet.

    Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao

    2017-08-01

    A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples. Graphical Abstract ᅟ.

  5. Monolithic spectrometer

    Rajic, Slobodan (Knoxville, TN); Egert, Charles M. (Oak Ridge, TN); Kahl, William K. (Knoxville, TN); Snyder, Jr., William B. (Knoxville, TN); Evans, III, Boyd M. (Oak Ridge, TN); Marlar, Troy A. (Knoxville, TN); Cunningham, Joseph P. (Oak Ridge, TN)

    1998-01-01

    A monolithic spectrometer is disclosed for use in spectroscopy. The spectrometer is a single body of translucent material with positioned surfaces for the transmission, reflection and spectral analysis of light rays.

  6. Interacting polytropic gas model of phantom dark energy in non-flat universe

    Karami, K.; Ghaffari, S.; Fehri, J.

    2009-01-01

    By introducing the polytropic gas model of interacting dark energy, we obtain the equation of state for the polytropic gas energy density in a non-flat universe. We show that for an even polytropic index by choosing K>Ba (3)/(n) , one can obtain ω Λ eff <-1, which corresponds to a universe dominated by phantom dark energy. (orig.)

  7. Extremes of 2d Coulomb gas: universal intermediate deviation regime

    Lacroix-A-Chez-Toine, Bertrand; Grabsch, Aurélien; Majumdar, Satya N.; Schehr, Grégory

    2018-01-01

    In this paper, we study the extreme statistics in the complex Ginibre ensemble of N × N random matrices with complex Gaussian entries, but with no other symmetries. All the N eigenvalues are complex random variables and their joint distribution can be interpreted as a 2d Coulomb gas with a logarithmic repulsion between any pair of particles and in presence of a confining harmonic potential v(r) \\propto r2 . We study the statistics of the eigenvalue with the largest modulus r\\max in the complex plane. The typical and large fluctuations of r\\max around its mean had been studied before, and they match smoothly to the right of the mean. However, it remained a puzzle to understand why the large and typical fluctuations to the left of the mean did not match. In this paper, we show that there is indeed an intermediate fluctuation regime that interpolates smoothly between the large and the typical fluctuations to the left of the mean. Moreover, we compute explicitly this ‘intermediate deviation function’ (IDF) and show that it is universal, i.e. independent of the confining potential v(r) as long as it is spherically symmetric and increases faster than \\ln r2 for large r with an unbounded support. If the confining potential v(r) has a finite support, i.e. becomes infinite beyond a finite radius, we show via explicit computation that the corresponding IDF is different. Interestingly, in the borderline case where the confining potential grows very slowly as v(r) ∼ \\ln r2 for r \\gg 1 with an unbounded support, the intermediate regime disappears and there is a smooth matching between the central part and the left large deviation regime.

  8. A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

    Rieker, G. B.; Poehlmann, F. R.; Cappelli, M. A.

    2013-01-01

    Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spe...

  9. Herschel-spire Fourier transform spectrometer observations of excited CO and [C I] in the antennae (NGC 4038/39): Warm and cold molecular gas

    Schirm, Maximilien R. P.; Wilson, Christine D.; Parkin, Tara J. [Department of Physics and Astronomy, McMaster University, Hamilton, ON L8S 4M1 (Canada); Kamenetzky, Julia; Glenn, Jason; Rangwala, Naseem [Center for Astrophysics and Space Astronomy, 389-UCB, University of Colorado, Boulder, CO 80303 (United States); Spinoglio, Luigi; Pereira-Santaella, Miguel [Istituto di Astrofisica e Planetologia Spaziali, INAF-IAPS, Via Fosso del Cavaliere 100, I-00133 Roma (Italy); Baes, Maarten; De Looze, Ilse [Sterrenkundig Observatorium, Universiteit Gent, Krijgslaan 281 S9, B-9000 Gent (Belgium); Barlow, Michael J. [Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT (United Kingdom); Clements, Dave L. [Astrophysics Group, Imperial College, Blackett Laboratory, Prince Consort Road, London SW7 2AZ (United Kingdom); Cooray, Asantha [Department of Physics and Astronomy, University of California, Irvine, CA 92697 (United States); Karczewski, Oskar Ł. [Department of Physics and Astronomy, University of Sussex, Brighton BN1 9QH (United Kingdom); Madden, Suzanne C.; Rémy-Ruyer, Aurélie; Wu, Ronin, E-mail: schirmmr@mcmaster.ca, E-mail: wilson@physics.mcmaster.ca [CEA, Laboratoire AIM, Irfu/SAp, Orme des Merisiers, F-91191 Gif-sur-Yvette (France)

    2014-02-01

    We present Herschel Spectral and Photometric Imaging Receiver (SPIRE) Fourier Transform Spectrometer (FTS) observations of the Antennae (NGC 4038/39), a well-studied, nearby (22 Mpc), ongoing merger between two gas-rich spiral galaxies. The SPIRE-FTS is a low spatial ( FWHM ∼ 19''-43'') and spectral (∼1.2 GHz) resolution mapping spectrometer covering a large spectral range (194-671 μm, 450-1545 GHz). We detect five CO transitions (J = 4-3 to J = 8-7), both [C I] transitions, and the [N II] 205 μm transition across the entire system, which we supplement with ground-based observations of the CO J = 1-0, J = 2-1, and J = 3-2 transitions and Herschel Photodetecting Array Camera and Spectrometer (PACS) observations of [C II] and [O I] 63 μm. Using the CO and [C I] transitions, we perform both a local thermodynamic equilibrium (LTE) analysis of [C I] and a non-LTE radiative transfer analysis of CO and [C I] using the radiative transfer code RADEX along with a Bayesian likelihood analysis. We find that there are two components to the molecular gas: a cold (T {sub kin} ∼ 10-30 K) and a warm (T {sub kin} ≳ 100 K) component. By comparing the warm gas mass to previously observed values, we determine a CO abundance in the warm gas of x {sub CO} ∼ 5 × 10{sup –5}. If the CO abundance is the same in the warm and cold gas phases, this abundance corresponds to a CO J = 1-0 luminosity-to-mass conversion factor of α{sub CO} ∼ 7 M {sub ☉} pc{sup –2} (K km s{sup –1}){sup –1} in the cold component, similar to the value for normal spiral galaxies. We estimate the cooling from H{sub 2}, [C II], CO, and [O I] 63 μm to be ∼0.01 L {sub ☉}/M {sub ☉}. We compare photon-dominated region models to the ratio of the flux of various CO transitions, along with the ratio of the CO flux to the far-infrared flux in NGC 4038, NGC 4039, and the overlap region. We find that the densities recovered from our non-LTE analysis are consistent with a

  10. Development of a gas-ionization {beta}-spectrometer; Etude et realisation d'un spectrometre {beta} a ionisation gazeuse

    Le Du, R [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1968-05-15

    We intend to develop in our laboratory a {beta}-spectrometer. This apparatus will have two main objectives: 1 - the determination of the nature and the degree of purity of certain {beta}-emitting radioactive substances; 2 - the study of an activity calibration process for {beta}-emitting radioactive sources. (author) [French] Nous nous proposons d'etudier et de realiser dans notre laboratoire un spectrometre {beta}. Cet appareil aura deux buts principaux: 1 - determiner la nature et le degre de purete de certains corps radioactifs emetteurs {beta}; 2 - permettre l'etude d'un procede d'etalonnage en activite de sources radioactives emetteurs {beta}. (auteur)

  11. Multidimensional spectrometer

    Zanni, Martin Thomas; Damrauer, Niels H.

    2010-07-20

    A multidimensional spectrometer for the infrared, visible, and ultraviolet regions of the electromagnetic spectrum, and a method for making multidimensional spectroscopic measurements in the infrared, visible, and ultraviolet regions of the electromagnetic spectrum. The multidimensional spectrometer facilitates measurements of inter- and intra-molecular interactions.

  12. Impact of nonlinearity on changing the a priori of trace gas profile estimates from the Tropospheric Emission Spectrometer (TES

    S. S. Kulawik

    2008-06-01

    Full Text Available Non-linear maximum a posteriori (MAP estimates of atmospheric profiles from the Tropospheric Emission Spectrometer (TES contains a priori information that may vary geographically, which is a confounding factor in the analysis and physical interpretation of an ensemble of profiles. One mitigation strategy is to transform profile estimates to a common prior using a linear operation thereby facilitating the interpretation of profile variability. However, this operation is dependent on the assumption of not worse than moderate non-linearity near the solution of the non-linear estimate. The robustness of this assumption is tested by comparing atmospheric retrievals from the Tropospheric Emission Spectrometer processed with a uniform prior with those processed with a variable prior and converted to a uniform prior following the non-linear retrieval. Linearly converting the prior following a non-linear retrieval is shown to have a minor effect on the results as compared to a non-linear retrieval using a uniform prior when compared to the expected total error, with less than 10% of the change in the prior ending up as unbiased fluctuations in the profile estimate results.

  13. High molecular gas fractions in normal massive star-forming galaxies in the young Universe.

    Tacconi, L J; Genzel, R; Neri, R; Cox, P; Cooper, M C; Shapiro, K; Bolatto, A; Bouché, N; Bournaud, F; Burkert, A; Combes, F; Comerford, J; Davis, M; Schreiber, N M Förster; Garcia-Burillo, S; Gracia-Carpio, J; Lutz, D; Naab, T; Omont, A; Shapley, A; Sternberg, A; Weiner, B

    2010-02-11

    Stars form from cold molecular interstellar gas. As this is relatively rare in the local Universe, galaxies like the Milky Way form only a few new stars per year. Typical massive galaxies in the distant Universe formed stars an order of magnitude more rapidly. Unless star formation was significantly more efficient, this difference suggests that young galaxies were much more molecular-gas rich. Molecular gas observations in the distant Universe have so far largely been restricted to very luminous, rare objects, including mergers and quasars, and accordingly we do not yet have a clear idea about the gas content of more normal (albeit massive) galaxies. Here we report the results of a survey of molecular gas in samples of typical massive-star-forming galaxies at mean redshifts of about 1.2 and 2.3, when the Universe was respectively 40% and 24% of its current age. Our measurements reveal that distant star forming galaxies were indeed gas rich, and that the star formation efficiency is not strongly dependent on cosmic epoch. The average fraction of cold gas relative to total galaxy baryonic mass at z = 2.3 and z = 1.2 is respectively about 44% and 34%, three to ten times higher than in today's massive spiral galaxies. The slow decrease between z approximately 2 and z approximately 1 probably requires a mechanism of semi-continuous replenishment of fresh gas to the young galaxies.

  14. Universal model for water costs of gas exchange by animals and plants

    Woods, H. Arthur; Smith, Jennifer N.

    2010-01-01

    For terrestrial animals and plants, a fundamental cost of living is water vapor lost to the atmosphere during exchange of metabolic gases. Here, by bringing together previously developed models for specific taxa, we integrate properties common to all terrestrial gas exchangers into a universal model of water loss. The model predicts that water loss scales to gas exchange with an exponent of 1 and that the amount of water lost per unit of gas exchanged depends on several factors: the surface t...

  15. Frequency-Modulation Correlation Spectrometer

    Margolis, J. S.; Martonchik, J. V.

    1985-01-01

    New type of correlation spectrometer eliminates need to shift between two cells, one empty and one containing reference gas. Electrooptical phase modulator sinusoidally shift frequencies of sample transmission spectrum.

  16. Reconstructing an interacting holographic polytropic gas model in a non-flat FRW universe

    Karami, K; Abdolmaleki, A

    2010-01-01

    We study the correspondence between the interacting holographic dark energy and the polytropic gas model of dark energy in a non-flat FRW universe. This correspondence allows one to reconstruct the potential and the dynamics for the scalar field of the polytropic model, which describe accelerated expansion of the universe.

  17. Reconstructing an interacting holographic polytropic gas model in a non-flat FRW universe

    Karami, K; Abdolmaleki, A, E-mail: KKarami@uok.ac.i [Department of Physics, University of Kurdistan, Pasdaran Street, Sanandaj (Iran, Islamic Republic of)

    2010-05-01

    We study the correspondence between the interacting holographic dark energy and the polytropic gas model of dark energy in a non-flat FRW universe. This correspondence allows one to reconstruct the potential and the dynamics for the scalar field of the polytropic model, which describe accelerated expansion of the universe.

  18. Low Power Consumption Lasers for Next Generation Miniature Optical Spectrometers for Major Constituent and Trace Gas Analysis

    Forouhar, Siamak; Soibel, Alexander; Frez, Clifford; Qiu, Yueming; Chen, J.; Hosoda, T.; Kipshidze, G.; Shterengas, L.; Tsvid, G.; Belenky, G.; hide

    2010-01-01

    The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. The minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental frequency of the target gases which are mostly in the 3.0-5.0 micrometers wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micrometers and quantum cascade (QC) lasers in the 4.0-5.0 micrometers range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

  19. Light meson gas in the QCD vacuum and oscillating universe

    Prokhorov, G.; Pasechnik, Roman

    2018-01-01

    Roč. 2018, č. 1 (2018), č. článku 017. ISSN 1475-7516 Institutional support: RVO:61389005 Keywords : particle physics - cosmology connection * cosmological phase transitions * physics of the early universe Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics,space science) Impact factor: 4.734, year: 2016

  20. Gas And Ice Spectrometer/Radar (GAISR): a new instrument for close-up comet activity observations

    Cooper, Ken; Monje, Raquel; Cochrane, Corey; Tang, Adrian; Alonso, Maria; Dengler, Robert; Durden, Stephen; Choukroun, Mathieu

    2017-10-01

    The Rosetta mission at 67P/Churyumov-Gerasimenko enabled the first detailed and long-term survey of cometary activity, which occurs primarily through water outgassing and emission of dust. Its highly-capable instrument suite improved our understanding of the outgassing and the dust emission and size distribution separately, however the coupling between the two remains poorly understood. GAISR consists of a dual-channel submillimeter-wave spectrometer inspired from MIRO/Rosetta, coupled to a small-particle Doppler radar for simultaneous observations of outgassing and emission of the large dust particles (comprising most of the mass emitted) in cometary jets and plumes of outer solar system satellites. GAISR’s medium-range W-band (95 GHz) radar will operate in a frequency-modulated continuous-wave (FMCW) mode with 1 Watt of transmit power to achieve high sensitivity detection of the range and velocity distribution of 0.1-10 mm sized ice and dust particles released by jets and plumes. The radar’s primary aperture also functions as an antenna for two passive heterodyne spectrometer channels at 270 and 560 GHz for detecting the abundance, temperature, and velocity of water vapor and its isotopes (including HDO), as well other major cometary volatiles such as CO, NH3, CH3OH. GAISR has been designed with a priority placed on low mass and power needs, to facilitate its infusion in future planetary missions. This is accomplished by leveraging recent innovations in W-band signal generation using low power silicon integrated circuits, state-of-the art III-V semiconductor devices for signal amplification and detection, and compact quasioptical duplexing. A new signal processing algorithm for FMCW Doppler radar detection out to the maximum range ambiguity limit has also been developed. GAISR’s performance testing has begun, and this poster will summarize its proven capabilities and plans for validation in relevant environments.

  1. Measuring Gas-Phase Basicities of Amino Acids Using an Ion Trap Mass Spectrometer: A Physical Chemistry Laboratory Experiment

    Sunderlin, Lee S.; Ryzhov, Victor; Keller, Lanea M. M.; Gaillard, Elizabeth R.

    2005-01-01

    An experiment is performed to measure the relative gas-phase basicities of a series of five amino acids to compare the results to literature values. The experiments use the kinetic method for deriving ion thermochemistry and allow students to perform accurate measurements of thermodynamics in a relatively short time.

  2. New model of universal gas-filled neutron tube

    Bespalov, D.F.; Bessarabskii, I.G.; Voitsik, L.R.; Mints, A.Z.

    1985-01-01

    The UNG-1 gas-filled neutron tube is serially produced. In type UNG neutron generators, the tube operates in the pulsed mode in the high voltage doubling circuit arrangement. During extended operation, its advantages were discovered: long operating time, fairly stable neutron yield, and simplicity of use and operation. However, the mean neutron yield (approx.10 7 s -1 ) generated by the tube in the optimal mode at the present time proved to be inadequate in solving numerous geophysical problems. So a model of a neutron tube, model UNG-2, was designed, ensuring an enhanced neutron yield of 10 8 s -1 in the continuous-operating mode. When the tube is connected to the high voltage doubling circuit, the mean neutron yield is only somewhat in excess of the neutron yield from the UNG-1 tube

  3. Streamlined Calibration of the ATLAS Muon Spectrometer Precision Chambers

    Levin, DS; The ATLAS collaboration; Dai, T; Diehl, EB; Ferretti, C; Hindes, JM; Zhou, B

    2009-01-01

    The ATLAS Muon Spectrometer is comprised of nearly 1200 optically Monitored Drifttube Chambers (MDTs) containing 354,000 aluminum drift tubes. The chambers are configured in barrel and endcap regions. The momentum resolution required for the LHC physics reach (dp/p = 3% and 10% at 100 GeV and 1 TeV) demands rigorous MDT drift tube calibration with frequent updates. These calibrations (RT functions) convert the measured drift times to drift radii and are a critical component to the spectrometer performance. They are sensitive to the MDT gas composition: Ar 93%, CO2 7% at 3 bar, flowing through the detector at arate of 100,000 l hr−1. We report on the generation and application of Universal RT calibrations derived from an inline gas system monitor chamber. Results from ATLAS cosmic ray commissioning data are included. These Universal RTs are intended for muon track reconstuction in LHC startup phase.

  4. Supersonic gas streams enhance the formation of massive black holes in the early universe.

    Hirano, Shingo; Hosokawa, Takashi; Yoshida, Naoki; Kuiper, Rolf

    2017-09-29

    The origin of super-massive black holes in the early universe remains poorly understood. Gravitational collapse of a massive primordial gas cloud is a promising initial process, but theoretical studies have difficulty growing the black hole fast enough. We report numerical simulations of early black hole formation starting from realistic cosmological conditions. Supersonic gas motions left over from the Big Bang prevent early gas cloud formation until rapid gas condensation is triggered in a protogalactic halo. A protostar is formed in the dense, turbulent gas cloud, and it grows by sporadic mass accretion until it acquires 34,000 solar masses. The massive star ends its life with a catastrophic collapse to leave a black hole-a promising seed for the formation of a monstrous black hole. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  5. Universal model for water costs of gas exchange by animals and plants.

    Woods, H Arthur; Smith, Jennifer N

    2010-05-04

    For terrestrial animals and plants, a fundamental cost of living is water vapor lost to the atmosphere during exchange of metabolic gases. Here, by bringing together previously developed models for specific taxa, we integrate properties common to all terrestrial gas exchangers into a universal model of water loss. The model predicts that water loss scales to gas exchange with an exponent of 1 and that the amount of water lost per unit of gas exchanged depends on several factors: the surface temperature of the respiratory system near the outside of the organism, the gas consumed (oxygen or carbon dioxide), the steepness of the gradients for gas and vapor, and the transport mode (convective or diffusive). Model predictions were largely confirmed by data on 202 species in five taxa--insects, birds, bird eggs, mammals, and plants--spanning nine orders of magnitude in rate of gas exchange. Discrepancies between model predictions and data seemed to arise from biologically interesting violations of model assumptions, which emphasizes how poorly we understand gas exchange in some taxa. The universal model provides a unified conceptual framework for analyzing exchange-associated water losses across taxa with radically different metabolic and exchange systems.

  6. HISS spectrometer

    Greiner, D.E.

    1984-11-01

    This talk describes the Heavy Ion Spectrometer System (HISS) facility at the Lawrence Berkeley Laboratory's Bevalac. Three completed experiments and their results are illustrated. The second half of the talk is a detailed discussion of the response of drift chambers to heavy ions. The limitations of trajectory measurement over a large range in incident particle charge are presented

  7. Universal Behavior of Pair Correlations in a Strongly Interacting Fermi Gas

    Kuhnle, E. D.; Hu, H.; Liu, X.-J.; Dyke, P.; Mark, M.; Drummond, P. D.; Hannaford, P.; Vale, C. J.

    2010-01-01

    We show that short-range pair correlations in a strongly interacting Fermi gas follow a simple universal law described by Tan's relations. This is achieved through measurements of the static structure factor which displays a universal scaling proportional to the ratio of Tan's contact to the momentum C/q. Bragg spectroscopy of ultracold 6 Li atoms from a periodic optical potential is used to measure the structure factor for a wide range of momenta and interaction strengths, providing broad confirmation of this universal law. We calibrate our Bragg spectra using the f-sum rule, which is found to improve the accuracy of the structure factor measurement.

  8. The Spectrometer

    Greenslade, Thomas B., Jr.

    2012-01-01

    In the fall of 1999 I was shown an Ocean Optics spectrometer-in-the-computer at St. Patricks College at Maynooth, Ireland, and thought that I had seen heaven. Of course, it could not resolve the sodium D-lines (I had done that many years before with a homemade wire diffraction grating), and I began to realize that inside was some familiar old…

  9. VEGAS: VErsatile GBT Astronomical Spectrometer

    Bussa, Srikanth; VEGAS Development Team

    2012-01-01

    The National Science Foundation Advanced Technologies and Instrumentation (NSF-ATI) program is funding a new spectrometer backend for the Green Bank Telescope (GBT). This spectrometer is being built by the CICADA collaboration - collaboration between the National Radio Astronomy Observatory (NRAO) and the Center for Astronomy Signal Processing and Electronics Research (CASPER) at the University of California Berkeley.The backend is named as VErsatile GBT Astronomical Spectrometer (VEGAS) and will replace the capabilities of the existing spectrometers. This backend supports data processing from focal plane array systems. The spectrometer will be capable of processing up to 1.25 GHz bandwidth from 8 dual polarized beams or a bandwidth up to 10 GHz from a dual polarized beam.The spectrometer will be using 8-bit analog to digital converters (ADC), which gives a better dynamic range than existing GBT spectrometers. There will be 8 tunable digital sub-bands within the 1.25 GHz bandwidth, which will enhance the capability of simultaneous observation of multiple spectral transitions. The maximum spectral dump rate to disk will be about 0.5 msec. The vastly enhanced backend capabilities will support several science projects with the GBT. The projects include mapping temperature and density structure of molecular clouds; searches for organic molecules in the interstellar medium; determination of the fundamental constants of our evolving Universe; red-shifted spectral features from galaxies across cosmic time and survey for pulsars in the extreme gravitational environment of the Galactic Center.

  10. Phase diagram and universality of the Lennard-Jones gas-liquid system

    Watanabe, Hiroshi

    2012-01-01

    The gas-liquid phase transition of the three-dimensional Lennard-Jones particles system is studied by molecular dynamics simulations. The gas and liquid densities in the coexisting state are determined with high accuracy. The critical point is determined by the block density analysis of the Binder parameter with the aid of the law of rectilinear diameter. From the critical behavior of the gas-liquid coexisting density, the critical exponent of the order parameter is estimated to be β = 0.3285(7). Surface tension is estimated from interface broadening behavior due to capillary waves. From the critical behavior of the surface tension, the critical exponent of the correlation length is estimated to be ν = 0.63(4). The obtained values of β and ν are consistent with those of the Ising universality class. © 2012 American Institute of Physics.

  11. The SAGE spectrometer: A tool for combined in-beam γ-ray and conversion electron spectroscopy

    Papadakis, P; Herzberg, R-D; Pakarinen, J; Butler, P A; Cox, D; Cresswell, J R; Parr, E; Sampson, J; Greenlees, P T; Sorri, J; Hauschild, K; Jones, P; Julin, R; Peura, P; Rahkila, P; Sandzelius, M; Coleman-Smith, P J; Lazarus, I H; Letts, S C; Pucknell, V F E

    2011-01-01

    The SAGE spectrometer allows simultaneous in-beam γ-ray and internal conversion electron measurements, by combining a germanium detector array with a highly segmented silicon detector and an electron transport system. SAGE is coupled with the ritu gas-filled recoil separator and the great focal-plane spectrometer for recoil-decay tagging studies. Digital electronics are used both for the γ ray and the electron parts of the spectrometer. SAGE was commissioned in the Accelerator Laboratory of the University of Jyvaeskylae in the beginning of 2010.

  12. The AMS [Accelerator Mass Spectrometer] program at LLNL

    Proctor, I.D.

    1988-09-01

    Livermore will have an operational Accelerator Mass Spectrometer (AMS) by mid-1989 as part of its new Multi-user Tandem Laboratory. The spectrometer was designed primarily for applications in archaeology and the geosciences and was co-funded by the University of California Regents. Radiological control for personnel protection, ion sources and injection systems, the tandem and all beam handling hardware are operated with a distributed processor computer control system. The Tandem is the former University of Washington injector FN which has been upgraded with Dowlish tubes, pelletron charging and SF 6 gas. Design goals for the AMS system, computer aided operation, automated measurement capability, initial results and some of our intended applications will be presented. 5 refs., 2 figs

  13. Scalar perturbations in the late Universe: viability of the Chaplygin gas models

    Bouhmadi-López, Mariam [Departamento de Física, Universidade da Beira Interior, 6200 Covilhã (Portugal); Brilenkov, Maxim; Brilenkov, Ruslan [Department of Theoretical Physics, Odessa National University, Dvoryanskaya st. 2, Odessa 65082 (Ukraine); Morais, João [Department of Theoretical Physics, University of the Basque Country UPV/EHU, P.O. Box 644, 48080 Bilbao (Spain); Zhuk, Alexander, E-mail: mbl@ubi.pt, E-mail: maxim.brilenkov@gmail.com, E-mail: ruslan.brilenkov@gmail.com, E-mail: jviegas001@ikasle.ehu.eus, E-mail: ai.zhuk2@gmail.com [Astronomical Observatory, Odessa National University, Dvoryanskaya st. 2, Odessa 65082 (Ukraine)

    2015-12-01

    We study the late-time evolution of the Universe where dark energy (DE) is parametrised by a modified generalised Chaplygin gas (mGCG) on top of cold dark matter (CDM) . We also take into account the radiation content of the Universe. In this context, the late stage of the evolution of the universe refers to the epoch where CDM is already clustered into inhomogeneously distributed discrete structures (galaxies, groups and clusters of galaxies). Under these conditions, the mechanical approach is an adequate tool to study the Universe deep inside the cell of uniformity. To be more accurate, we study scalar perturbations of the Friedmann-Lemaȋtre-Robertson-Walker metric due to inhomogeneities of CDM as well as fluctuations of radiation and mGCG, the later driving the late-time acceleration of the universe. Our analysis applies as well to the case where mGCG plays the role of DM and DE . We select the sets of parameters of the mGCG that are compatible with the mechanical approach. These sets define prospective mGCG models. By comparing the selected sets of models with some of the latest observational data results, we conclude that the mGCG is in tight agreement with those observations particularly for a mGCG playing the role of DE and DM.

  14. Universality and Quantum Criticality of the One-Dimensional Spinor Bose Gas

    PâÅ£u, Ovidiu I.; Klümper, Andreas; Foerster, Angela

    2018-06-01

    We investigate the universal thermodynamics of the two-component one-dimensional Bose gas with contact interactions in the vicinity of the quantum critical point separating the vacuum and the ferromagnetic liquid regime. We find that the quantum critical region belongs to the universality class of the spin-degenerate impenetrable particle gas which, surprisingly, is very different from the single-component case and identify its boundaries with the peaks of the specific heat. In addition, we show that the compressibility Wilson ratio, which quantifies the relative strength of thermal and quantum fluctuations, serves as a good discriminator of the quantum regimes near the quantum critical point. Remarkably, in the Tonks-Girardeau regime, the universal contact develops a pronounced minimum, reflected in a counterintuitive narrowing of the momentum distribution as we increase the temperature. This momentum reconstruction, also present at low and intermediate momenta, signals the transition from the ferromagnetic to the spin-incoherent Luttinger liquid phase and can be detected in current experiments with ultracold atomic gases in optical lattices.

  15. Small angle spectrometers: Summary

    Courant, E.; Foley, K.J.; Schlein, P.E.

    1986-01-01

    Aspects of experiments at small angles at the Superconducting Super Collider are considered. Topics summarized include a small angle spectrometer, a high contingency spectrometer, dipole and toroid spectrometers, and magnet choices

  16. Steady-state modelling of the universal exhaust gas oxygen (UEGO) sensor

    Collings, N; Hegarty, K; Ramsander, T

    2012-01-01

    The universal exhaust gas oxygen (UEGO) sensor is a well-established device which was developed for the measurement of relative air fuel ratio in internal combustion engines. There is, however, little information available which allows for the prediction of the UEGO's behaviour when exposed to arbitrary gas mixtures, pressures and temperatures. Here we present a steady-state model for the sensor, based on a solution of the Stefan–Maxwell equation, and which includes a momentum balance. The response of the sensor is dominated by a diffusion barrier, which controls the rate of diffusion of gas species between the exhaust and a cavity. Determination of the diffusion barrier characteristics, especially the mean pore size, porosity and tortuosity, is essential for the purposes of modelling, and a measurement technique based on identification of the sensor pressure giving zero temperature sensitivity is shown to be a convenient method of achieving this. The model, suitably calibrated, is shown to make good predictions of sensor behaviour for large variations of pressure, temperature and gas composition. (paper)

  17. Digital Spectrometers for Interplanetary Science Missions

    Jarnot, Robert F.; Padmanabhan, Sharmila; Raffanti, Richard; Richards, Brian; Stek, Paul; Werthimer, Dan; Nikolic, Borivoje

    2010-01-01

    A fully digital polyphase spectrometer recently developed by the University of California Berkeley Wireless Research Center in conjunction with the Jet Propulsion Laboratory provides a low mass, power, and cost implementation of a spectrum channelizer for submillimeter spectrometers for future missions to the Inner and Outer Solar System. The digital polyphase filter bank spectrometer (PFB) offers broad bandwidth with high spectral resolution, minimal channel-to-channel overlap, and high out-of-band rejection.

  18. Smartphone Spectrometers

    Willmott, Jon R.; Mims, Forrest M.; Parisi, Alfio V.

    2018-01-01

    Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades. PMID:29342899

  19. Smartphone Spectrometers

    Andrew J.S. McGonigle

    2018-01-01

    Full Text Available Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades.

  20. Cosmological Imprints of a Generalized Chaplygin Gas Model for the Early Universe

    Bouhmadi-Lopez, Mariam; /Lisbon, CENTRA; Chen, Pisin; /Taiwan, Natl. Taiwan U. /KIPAC, Menlo Park /SLAC; Liu, Yen-Wei; /Taiwan, Natl. Taiwan U.

    2012-06-06

    We propose a phenomenological model for the early universe where there is a smooth transition between an early quintessence phase and a radiation-dominated era. The matter content is modeled by an appropriately modified Chaplygin gas for the early universe. We constrain the model observationally by mapping the primordial power spectrum of the scalar perturbations to the latest data of WMAP7. We compute as well the spectrum of the primordial gravitational waves as would be measured today. We show that the high frequencies region of the spectrum depends on the free parameter of the model and most importantly this region of the spectrum can be within the reach of future gravitational waves detectors.

  1. Testing the universality of the star-formation efficiency in dense molecular gas

    Shimajiri, Y.; André, Ph.; Braine, J.; Könyves, V.; Schneider, N.; Bontemps, S.; Ladjelate, B.; Roy, A.; Gao, Y.; Chen, H.

    2017-08-01

    Context. Recent studies with, for example, Spitzer and Herschel have suggested that star formation in dense molecular gas may be governed by essentially the same "law" in Galactic clouds and external galaxies. This conclusion remains controversial, however, in large part because different tracers have been used to probe the mass of dense molecular gas in Galactic and extragalactic studies. Aims: We aimed to calibrate the HCN and HCO+ lines commonly used as dense gas tracers in extragalactic studies and to test the possible universality of the star-formation efficiency in dense gas (≳104 cm-3), SFEdense. Methods: We conducted wide-field mapping of the Aquila, Ophiuchus, and Orion B clouds at 0.04 pc resolution in the J = 1 - 0 transition of HCN, HCO+, and their isotopomers. For each cloud, we derived a reference estimate of the dense gas mass MHerschelAV > 8, as well as the strength of the local far-ultraviolet (FUV) radiation field, using Herschel Gould Belt survey data products, and estimated the star-formation rate from direct counting of the number of Spitzer young stellar objects. Results: The H13CO+(1-0) and H13CN(1-0) lines were observed to be good tracers of the dense star-forming filaments detected with Herschel. Comparing the luminosities LHCN and LHCO+ measured in the HCN and HCO+ lines with the reference masses MHerschelAV > 8, the empirical conversion factors αHerschel - HCN (=MHerschelAV > 8/LHCN) and αHerschel - HCO+ (=MHerschelAV > 8/LHCO+) were found to be significantly anti-correlated with the local FUV strength. In agreement with a recent independent study of Orion B by Pety et al., the HCN and HCO+ lines were found to trace gas down to AV ≳ 2. As a result, published extragalactic HCN studies must be tracing all of the moderate density gas down to nH2 ≲ 103 cm-3. Estimating the contribution of this moderate density gas from the typical column density probability distribution functions in nearby clouds, we obtained the following G0

  2. Universal stability curve for pattern formation in pulsed gas-solid fluidized beds of sandlike particles

    de Martín, Lilian; Ottevanger, Coen; van Ommen, J. Ruud; Coppens, Marc-Olivier

    2018-03-01

    A granular layer can form regular patterns, such as squares, stripes, and hexagons, when it is fluidized with a pulsating gas flow. These structures are reminiscent of the well-known patterns found in granular layers excited through vibration, but, contrarily to them, they have been hardly explored since they were first discovered. In this work, we investigate experimentally the conditions leading to pattern formation in pulsed fluidized beds and the dimensionless numbers governing the phenomenon. We show that the onset to the instability is universal for Geldart B (sandlike) particles and governed by the hydrodynamical parameters Γ =ua/(utϕ ¯) and f /fn , where ua and f are the amplitude and frequency of the gas velocity, respectively, ut is the terminal velocity of the particles, ϕ ¯ is the average solids fraction, and fn is the natural frequency of the bed. These findings suggest that patterns emerge as a result of a parametric resonance between the kinematic waves originating from the oscillating gas flow and the bulk dynamics. Particle friction plays virtually no role in the onset to pattern formation, but it is fundamental for pattern selection and stabilization.

  3. Gas, Dust, and Quenching of Dusty Galaxies in the Early Universe

    Spilker, Justin Scott

    In this dissertation, I study various aspects related to the gas and star formation in dusty star-forming galaxies in the distant universe. My dissertation is heavily based on observations made by the Atacama Large Millimeter/submillimeter Array (ALMA), observing a sample of gravitationally lensed high-redshift dusty galaxies originally discovered by the South Pole Telescope (SPT). In addition to the introductions to the individual chapters, Chapter 1 provides a broader background to the study of these objects and places them in the overall context of galaxy evolution. In Chapter 2 I describe a technique designed to search for faint molecular lines in the spectrum of high-redshift dusty galaxies. The brightest molecular lines in the spectra of these objects are due to carbon monoxide, but a host of other species are present in the interstellar media. These other molecules trace gas of a wide range of temperatures and densities, but are generally ten times fainter than the brighter CO lines. I detected several other molecular lines, and used them to characterize the conditions of the interstellar gas. This work was published in Spilker et al. (2014). In Chapter 3, I describe a technique for modeling the effects of gravitational lensing which is optimized for data from interferometers such as ALMA. Using these models and data for a large sample of objects from ALMA, I studied the intrinsic properties of the sample such as the source sizes and luminosities. I used these intrinsic properties to revisit topics from the literature which benefit from the additional size information I determined. This work was published in Spilker et al. (2016). In Chapter 4, I use the modeling technique I developed to investigate the relationship between the star formation and the cold molecular gas from which stars form in two objects selected from the SPT sample. Using the models of the source, I was able to determine the mass of molecular gas in these objects using several independent

  4. The TRIUMF low energy pion spectrometer and channel

    Sobie, R.J.; Drake, T.E.; Barnett, B.M.; Erdman, K.L.; Gyles, W.; Johnson, R.R.; Roser, H.W.; Tacik, R.; Blackmore, E.W.; Gill, D.R.

    1983-08-01

    A low energy pion spectrometer has been developed for use with the TRIUMF M13 pion channel. The combined channel and spectrometer resolution is presently 1.1 MeV at T = 50 MeV. This is limited by the amount of gas and detector material in the spectrometer in addition to the inherent resolution of the channel. Improvements to both the spectrometer and channel are discussed

  5. Energy Consumption and Greenhouse Gas Emission Evaluation Scenarios of Mea Fah Luang University

    Laingoen Onn

    2016-01-01

    Full Text Available In Thailand, quantity of the educational institutes building shared one fourth of commercial building. Among the energy consumption and conservation in the building in Thailand are mostly study in typical office and resident building. Mea Fah Luang University (MFU was selected to represent the educational institutes building where located in the northern part of Thailand. The average temperature in the northern is lower than other parts of Thailand. This study was firstly collected the data about quantity and behaviour of energy consumption in MFU based on the energy audit handbook. Although MFU is located in the northern of Thailand. The highest energy consumption is in the part of air condition. When the energy efficiency appliances and energy conservation building are implemented, the cost of energy will be saved around 15,867,960 Baht. Furthermore, the greenhouse gas emission is also reduced about 72.01 kg CO2, equivalent/m2/year.

  6. A new Masters program in Greenhouse Gas Management and Accounting at Colorado State University

    Conant, R. T.; Ogle, S. M.

    2015-12-01

    Management guru Peter Drucker said that "what gets measured gets managed." But the unstated implication is that what doesn't get measured doesn't get managed. Accurate quantification of greenhouse gas mitigation efforts is central to the clean technology sector. Very soon professionals of all kinds (business people, accountants, lawyers) will need to understand carbon accounting and crediting. Over the next few decades food production is expected to double and energy production must triple in order to meet growing global demands; sustainable management of land use and agricultural systems will be critical. The food and energy supply challenges are inextricably linked to the challenge of limiting anthropogenic impacts on climate by reducing the concentration of greenhouse gases (GHG) in the atmosphere. To avoid serious disruption of the climate system and stabilize GHG concentrations, society must move aggressively to avoid emissions of CO2, CH4, and N2O and to actively draw down CO2 already in the atmosphere. A new cadre of technically adept professionals is needed to meet these challenges. We describe a new professional Masters degree in greenhouse gas management and accounting at Colorado State University. This effort leverages existing, internationally-recognized expertise from across campus and partners from agencies and industry, enabling students from diverse backgrounds to develop the skills needed to fill this emerging demand.

  7. The current status of the Gas Electron Multiplier (GEM) research at Kasetsart University, Thailand

    Kumpiranon, P.; Kulasri, K.; Rittirong, A.; Saenboonruang, K.

    2017-06-01

    During the past decade, Gas Electron Multiplier (GEM) detectors have been greatly developed and utilized in numbers of applications including advanced nuclear and particle researches, medical imaging, astrophysics, and neutron detection for national security. Our GEM research group at the Department of Applied Radiation and Isotopes, Faculty of Science, Kasetsart University, Thailand, realized in its excellent properties/potentials and started extensive researches on GEM detectors. To build a strong foundation on our research group, two 10 cm × 10 cm triple GEM detectors were characterized on their important properties including absolute gains and detection uniformity. Moreover, to widen applications of the GEM detector, our group had modified the GEM detector by introducing either solid or gaseous neutron converters to the detector so that the detector could effectively detect neutrons. These modifications included coating a thin film of 10B and natB to the GEM drift cathode for thermal neutron detection and flowing a gas mixture of He/CO2 (80:20 and 70:30) and C4H10/He/CO2 (7:70:23) for fast neutron detection. Results showed that the modified GEM-based neutron detector could detect both types of neutrons with different relative efficiencies and gains depending on thicknesses and types of neutron converters. This article discusses basic knowledge of the GEM detector, construction and testing procedures, results, and discussion.

  8. Searching for perfect fluids: quantum viscosity in a universal Fermi gas

    Cao, C; Elliott, E; Wu, H; Thomas, J E

    2011-01-01

    We measure the shear viscosity in a two-component Fermi gas of atoms, tuned to a broad s-wave collisional (Feshbach) resonance. At resonance, the atoms strongly interact and exhibit universal behavior, where the equilibrium thermodynamic properties and transport coefficients are universal functions of density n and temperature T. We present a new calibration of the temperature as a function of global energy, which is directly measured from the cloud profiles. Using the calibration, the trap-averaged shear viscosity in units of ℎn is determined as a function of the reduced temperature at the trap center, from nearly the ground state to the unitary two-body regime. Low-temperature data are obtained from the damping rate of the radial breathing mode, whereas high-temperature data are obtained from hydrodynamic expansion measurements. We also show that the best fit to the high-temperature expansion data is obtained for a vanishing bulk viscosity. The measured trap-averaged entropy per particle and shear viscosity are used to estimate the ratio of shear viscosity to entropy density, which is compared with that conjectured for a perfect fluid.

  9. The universal sound velocity formula for the strongly interacting unitary Fermi gas

    Liu Ke; Chen Ji-Sheng

    2011-01-01

    Due to the scale invariance, the thermodynamic laws of strongly interacting limit unitary Fermi gas can be similar to those of non-interacting ideal gas. For example, the virial theorem between pressure and energy density of the ideal gas P = 2E/3V is still satisfied by the unitary Fermi gas. This paper analyses the sound velocity of unitary Fermi gases with the quasi-linear approximation. For comparison, the sound velocities for the ideal Boltzmann, Bose and Fermi gas are also given. Quite interestingly, the sound velocity formula for the ideal non-interacting gas is found to be satisfied by the unitary Fermi gas in different temperature regions. (general)

  10. Perspectives of Super-Heavy Nuclei research with the upcoming separator-spectrometer setup S3 at GANIL/SPIRAL2 - The VAMOS Gas-Filled separator and AGATA

    Theisen, Christophe

    2017-11-01

    Several facilities or apparatus for the synthesis and spectroscopy of the Super-Heavy Nuclei (SHN) are presently under construction in the world, which reflect the large interest for this region of extreme mass and charge, but also for the need of even more advanced research infrastructures. Among this new generation, the GANIL/SPIRAL2 facility in Caen, France, will soon deliver very high intense ion beams of several tens of particle μA. The Super Separator Spectrometer S3 has been designed to exploit these new beams for the study of SHN after separation. It will provide the needed beam rejection, mass selection and full arsenal of state-of-the art detection setups. Still at GANIL, the AGATA new generation gamma-ray tracking array is being operated. The VAMOS high acceptance spectrometer is being upgraded as a gas-filled separator. Its coupling with AGATA will lower the spectroscopic limits for the prompt gamma-ray studies of heavy and super-heavy nuclei. In this proceeding, these new devices will be presented along with a selected physics case.

  11. University Students Explaining Adiabatic Compression of an Ideal Gas--A New Phenomenon in Introductory Thermal Physics

    Leinonen, Risto; Asikainen, Mervi A.; Hirvonen, Pekka E.

    2012-01-01

    This study focuses on second-year university students' explanations and reasoning related to adiabatic compression of an ideal gas. The phenomenon was new to the students, but it was one which they should have been capable of explaining using their previous upper secondary school knowledge. The students' explanations and reasoning were…

  12. Development and miniaturization of a photoacoustic silicon integrated spectrometer for trace gas analysis; Etude et developpement d`un spectrometre photoacoustique integre sur silicium pour analyse de gaz

    Jourdain, A.

    1998-10-29

    The study deals with the integration on silicon wafers of an infrared spectrometer for carbon dioxide measurements. Photoacoustic detection that measures a differential pressure in a cavity turns out to be the best spectroscopic technique for miniaturization and integration. The micro-system is composed of two main components: an infrared light source on a silicon nitride membrane and a component integrating a tunable optical filter, a microphone for detection and a micro-cavity. After a theoretical study of the different components, each element is realized with the microelectronic techniques such as photolithography, thin films deposits and dry and wet etching. A resin sealing of all the different elements realizes the final micro-spectrophotometer. A characterization of the components is done thanks to the realization of an electronic specific set-up. (author) 107 refs.

  13. Universal relations for spin-orbit-coupled Fermi gas near an s -wave resonance

    Zhang, Pengfei; Sun, Ning

    2018-04-01

    Synthetic spin-orbit-coupled quantum gases have been widely studied both experimentally and theoretically in the past decade. As shown in previous studies, this modification of single-body dispersion will in general couple different partial waves of the two-body scattering and thus distort the wave function of few-body bound states which determines the short-distance behavior of many-body wave function. In this work, we focus on the two-component Fermi gas with one-dimensional or three-dimensional spin-orbit coupling (SOC) near an s -wave resonance. Using the method of effective field theory and the operator product expansion, we derive universal relations for both systems, including the adiabatic theorem, viral theorem, and pressure relation, and obtain the momentum distribution matrix 〈ψa†(q ) ψb(q ) 〉 at large q (a ,b are spin indices). The momentum distribution matrix shows both spin-dependent and spatial anisotropic features. And the large momentum tail is modified at the subleading order thanks to the SOC. We also discuss the experimental implication of these results depending on the realization of the SOC.

  14. In situ measurements of krypton in xenon gas with a quadrupole mass spectrometer following a cold-trap at a temporarily reduced pumping speed

    Brown, E; Rosendahl, S; Huhmann, C; Weinheimer, C; Kettling, H

    2013-01-01

    A new method for measuring trace amounts of krypton in xenon using a cold trap with a residual gas analyzer has been developed, which achieves an increased sensitivity by temporarily reducing the pumping speed while expending a minimal amount of xenon. By partially closing a custom built butterfly valve between the measurement chamber and the turbomolecular pump, a sensitivity of 40 ppt has been reached. This method has been tested on an ultra-pure gas sample from Air Liquide with an unknown intrinsic krypton concentration, yielding a krypton concentration of 330±200 ppt.

  15. Spherical grating spectrometers

    O'Donoghue, Darragh; Clemens, J. Christopher

    2014-07-01

    We describe designs for spectrometers employing convex dispersers. The Offner spectrometer was the first such instrument; it has almost exclusively been employed on satellite platforms, and has had little impact on ground-based instruments. We have learned how to fabricate curved Volume Phase Holographic (VPH) gratings and, in contrast to the planar gratings of traditional spectrometers, describe how such devices can be used in optical/infrared spectrometers designed specifically for curved diffraction gratings. Volume Phase Holographic gratings are highly efficient compared to conventional surface relief gratings; they have become the disperser of choice in optical / NIR spectrometers. The advantage of spectrometers with curved VPH dispersers is the very small number of optical elements used (the simplest comprising a grating and a spherical mirror), as well as illumination of mirrors off axis, resulting in greater efficiency and reduction in size. We describe a "Half Offner" spectrometer, an even simpler version of the Offner spectrometer. We present an entirely novel design, the Spherical Transmission Grating Spectrometer (STGS), and discuss exemplary applications, including a design for a double-beam spectrometer without any requirement for a dichroic. This paradigm change in spectrometer design offers an alternative to all-refractive astronomical spectrometer designs, using expensive, fragile lens elements fabricated from CaF2 or even more exotic materials. The unobscured mirror layout avoids a major drawback of the previous generation of catadioptric spectrometer designs. We describe laboratory measurements of the efficiency and image quality of a curved VPH grating in a STGS design, demonstrating, simultaneously, efficiency comparable to planar VPH gratings along with good image quality. The stage is now set for construction of a prototype instrument with impressive performance.

  16. The Dynamics and Cold Gas Content of Luminous Infrared Galaxy Mergers in the Local Universe

    Privon, G. C.

    2014-08-01

    Luminous Infrared Galaxies (LIRGs; 10^11 ≤ L_IR [8 - 1000 μm]/L_sun systems in the local universe, both in terms of their absolute star formation rates—ten to several hundred times that of ``normal'' galaxies—and their star formation rate densities. Many U/LIRGs are interacting or merging disk galaxies undergoing enhanced star formation and/or nuclear activity, likely triggered as the objects transform into massive S0 and elliptical merger remnants. The LIRG population also contains a significant number of apparently isolated disk galaxies which are undergoing enhanced star formation, providing a window on secular galaxy evolution. This work examines nearby U/LIRGs chosen from the Great Observatories All-sky LIRG Survey (GOALS), an infrared flux and luminosity selected sample. The proximity of these systems enables high spatial resolution study of active galactic nuclei (AGN) and extreme star formation in these objects. New maps of the neutral hydrogen (HI) emission are presented for systems morphologically classified in the optical and mid-infrared as non-merging or pre-merger systems. The results of this study suggests that some infrared-selected galaxies may be minor mergers or interactions which are being viewed so soon after first pass that the stellar disk has not yet been significantly disturbed. Galaxy mergers appear to drive much of the enhanced activity observed in U/LIRGs; understanding the merger state of these systems provides a context for observations of star formation and AGN properties. In order to constrain the merger stage, dynamical models for a sample of nine systems were matched to the observed kinematics and morphology as obtained from optical imaging and interferometric HI maps. The resulting models are used not only to constrain the merger stage, but also the encounter geometry of the precursor. Based on these dynamical models a new merger stage classification is presented, which re-scales objects to a common timeline is used to

  17. The SPEDE spectrometer

    Papadakis, P.; Cox, D. M.; O'Neill, G. G.; Borge, M. J. G.; Butler, P. A.; Gaffney, L. P.; Greenlees, P. T.; Herzberg, R.-D.; Illana, A.; Joss, D. T.; Konki, J.; Kröll, T.; Ojala, J.; Page, R. D.; Rahkila, P.; Ranttila, K.; Thornhill, J.; Tuunanen, J.; Van Duppen, P.; Warr, N.; Pakarinen, J.

    2018-03-01

    The electron spectrometer, SPEDE, has been developed and will be employed in conjunction with the Miniball spectrometer at the HIE-ISOLDE facility, CERN. SPEDE allows for direct measurement of internal conversion electrons emitted in-flight, without employing magnetic fields to transport or momentum filter the electrons. Together with the Miniball spectrometer, it enables simultaneous observation of γ rays and conversion electrons in Coulomb excitation experiments using radioactive ion beams.

  18. In situ measurements of krypton in xenon gas with a quadrupole mass spectrometer following a cold-trap at a temporarily reduced pumping speed

    Brown, Ethan; Rosendahl, Stephan; Huhmann, Christian; Kettling, Hans; Schlak, Martin; Weinheimer, Christian [Muenster Univ. (Germany). Inst. fuer Kernphysik

    2013-07-01

    Liquid xenon detectors have risen to be extremely competitive for dark matter and neutrinoless double-beta decay searches. In order to achieve the required sensitivity, backgrounds must be reduced substantially. One important background is the beta-decay of {sup 85}Kr, which constitutes a uniform internal background in liquid xenon detectors. Cryogenic distillation can be used to reduce the krypton concentration to acceptable levels, but gas diagnostics become incredibly difficult at these ultra-pure levels. A new method for measuring the concentration of krypton in xenon has been developed, expanding on the existing technique of a cold trap and a Residual Gas Analyzer (RGA). By using a liquid nitrogen cold trap, one can take advantage of the difference in vapor pressures of krypton in xenon to freeze most of the xenon gas while allowing the krypton to pass to the measurement chamber. Here, only a few milliliters of xenon is expended in the measurement, while achieving a sensitivity of sub ppb (parts per billion). The key change is the use of a butterfly valve to partially close the opening in front of the turbomolecular pump, thereby reducing the effective pumping speed and enhancing the RGA signal.

  19. Mass spectrometers in medicine

    Bushman, J.A.

    1975-01-01

    This paper describes how the mass spectrometer enables true lung function, namely the exchange of gases between the environment and the organism, to be measured. This has greatly improved the understanding of respiratory disease and the latest generation of respiratory mass spectrometers will do much to increase the application of the technique. (author)

  20. The Omicron Spectrometer

    Allardyce, B W

    1976-01-01

    It is intended to build a spectrometer with a large solid angle and a large momentum acceptance at the reconstructed synchrocyclotron at CERN. This spectrometer will have an energy resolution of about 1 MeV for particles with momenta up to about 400 MeV/c.

  1. Universal relations of an ultracold Fermi gas with arbitrary spin-orbit coupling

    Jie, Jianwen; Qi, Ran; Zhang, Peng

    2018-05-01

    We derive the universal relations for an ultracold two-component Fermi gas with a spin-orbit coupling (SOC) ∑α,β =x ,y ,zλα βσαpβ , where px ,y ,z and σx ,y ,z are the single-atom momentum and Pauli operators for pseudospin, respectively, and the SOC intensity λα β could take an arbitrary value. We consider the system with an s -wave short-range interspecies interaction, and ignore the SOC-induced modification for the value of the scattering length. Using the first-quantized approach developed by Tan [S. Tan, Phys. Rev. Lett. 107, 145302 (2011), 10.1103/PhysRevLett.107.145302], we obtain the short-range and high-momentum expansions for the one-body real-space correlation function and momentum distribution function, respectively. For our system these functions are a 2 ×2 matrix in the pseudospin basis. We find that the leading-order (1 /k4 ) behavior of the diagonal elements of the momentum distribution function, i.e., n↑↑(k ) and n↓↓(k ) , are not modified by the SOC. However, the SOC can significantly modify the large-k behaviors of the distribution difference δ n (k ) ≡n↑↑(k ) -n↓↓(k ) as well as the nondiagonal elements of the momentum distribution function, i.e., n↑↓(k ) and n↓↑(k ) . In the absence of the SOC, the leading order of δ n (k ) , n↑↓(k ) , and n↓↑(k ) is O (1 /k6) . When SOC appears, it can induce a term on the order of 1 /k5 for these elements. We further derive the adiabatic relation and the energy functional. Our results show that the SOC can induce an additional term in the energy functional, which describes the contribution from the SOC to the total energy. In addition, the form of the adiabatic relation for our system is not modified by the SOC. Our results are applicable for the systems with any type of single-atom trapping potential, which could be either diagonal or nondiagonal in the pseudospin basis.

  2. Wide-aperture magnetic spectrometer with face position of MWPC

    Avakyan, R.O.; Avetisyan, A.Eh.; Ajvazyan, R.B.; Asaturyan, R.A.; Dallakyan, K.R.; Kizogyan, O.S.; Matevosyan, Eh.M.; Sukiasyan, Yu.Z.; Taroyan, S.P.

    1988-01-01

    A pair magnetic spectrometer with automated wire chambers for studying electron and positron interactions with monocrystals at the Erevan synchrotron is described. As a working gas the argon-methane mixture with methylal vapor addition is used. Results of modelling and experiments with spectrometer are presented. 2 refs.; 6 figs

  3. Upgrade of the NASA 4STAR (Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research) to its Full Science Capability of Sun-Sky-Cloud-Trace Gas Spectrometry in Airborne Science Deployments

    Johnson, Roy R.; Russell, P.; Dunagan, S.; Redemann, J.; Shinozuka, Y.; Segal-Rosenheimer, M.; LeBlanc, S.; Flynn, C.; Schmid, B.; Livingston, J.

    2014-01-01

    The objectives of this task in the AITT (Airborne Instrument Technology Transition) Program are to (1) upgrade the NASA 4STAR (Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research) instrument to its full science capability of measuring (a) direct-beam sun transmission to derive aerosol optical depth spectra, (b) sky radiance vs scattering angle to retrieve aerosol absorption and type (via complex refractive index spectra, shape, and mode-resolved size distribution), (c) zenith radiance for cloud properties, and (d) hyperspectral signals for trace gas retrievals, and (2) demonstrate its suitability for deployment in challenging NASA airborne multiinstrument campaigns. 4STAR combines airborne sun tracking, sky scanning, and zenith pointing with diffraction spectroscopy to improve knowledge of atmospheric constituents and their links to air pollution, radiant energy budgets (hence climate), and remote measurements of Earth's surfaces. Direct beam hyperspectral measurement of optical depth improves retrievals of gas constituents and determination of aerosol properties. Sky scanning enhances retrievals of aerosol type and size distribution. 4STAR measurements are intended to tighten the closure between satellite and ground-based measurements. 4STAR incorporates a modular sun-tracking/sky-scanning optical head with fiber optic signal transmission to rack mounted spectrometers, permitting miniaturization of the external optical head, and future detector evolution. 4STAR test flights, as well as science flights in the 2012-13 TCAP (Two-Column Aerosol Project) and 2013 SEAC4RS (Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys) have demonstrated that the following are essential for 4STAR to achieve its full science potential: (1) Calibration stability for both direct-beam irradiance and sky radiance, (2) Improved light collection and usage, and (3) Improved flight operability and reliability. A particular challenge

  4. Gone with the heat: a fundamental constraint on the imaging of dust and molecular gas in the early Universe.

    Zhang, Zhi-Yu; Papadopoulos, Padelis P; Ivison, R J; Galametz, Maud; Smith, M W L; Xilouris, Emmanuel M

    2016-06-01

    Images of dust continuum and carbon monoxide (CO) line emission are powerful tools for deducing structural characteristics of galaxies, such as disc sizes, H2 gas velocity fields and enclosed H2 and dynamical masses. We report on a fundamental constraint set by the cosmic microwave background (CMB) on the observed structural and dynamical characteristics of galaxies, as deduced from dust continuum and CO-line imaging at high redshifts. As the CMB temperature rises in the distant Universe, the ensuing thermal equilibrium between the CMB and the cold dust and H2 gas progressively erases all spatial and spectral contrasts between their brightness distributions and the CMB. For high-redshift galaxies, this strongly biases the recoverable H2 gas and dust mass distributions, scale lengths, gas velocity fields and dynamical mass estimates. This limitation is unique to millimetre/submillimetre wavelengths and unlike its known effect on the global dust continuum and molecular line emission of galaxies, it cannot be addressed simply. We nevertheless identify a unique signature of CMB-affected continuum brightness distributions, namely an increasing rather than diminishing contrast between such brightness distributions and the CMB when the cold dust in distant galaxies is imaged at frequencies beyond the Raleigh-Jeans limit. For the molecular gas tracers, the same effect makes the atomic carbon lines maintain a larger contrast than the CO lines against the CMB.

  5. Dynamics and Evolution of SO 2 Gas Condensation around Prometheus-like Volcanic Plumes on Io as Seen by the Near Infrared Mapping Spectrometer

    Douté, Sylvain; Lopes, Rosaly; Kamp, Lucas W.; Carlson, Robert; Schmitt, Bernard; Galileo NIMS Team

    2002-08-01

    We analyze a series of spectral image cubes acquired by the Galileo Near Infrared Mapping Spectrometer (NIMS) over the Prometheus region of Io. We use SO 2 frost, a volatile compound ubiquitous on the surface, as a tracer to understand various thermodynamic and volcanic processes acting in this equatorial region. Here we develop a new method to derive, from the 12-wavelength NIMS products, the distribution and physical properties of solid SO 2. This method is based on the inversion of a bidirectional reflectance model on two observed spectral ratios sensitive to (1) the areal abundance of SO 2 and (2) its mean grain size. As a result, reliable and consistent maps of SO 2 abundance and granularity are obtained which can be correlated to distinguish four different physical units. The distribution of these SO 2 units indicates zones of condensation, metamorphism, and sublimation linked with the thermodynamic and volcanic processes of interest. Our maps depict equatorial plains undisturbed by any kind of vigorous volcanic activity over 35-40% of their surface. Elsewhere, 10-20% of the equatorial plains display abnormally low frost coverage which may imply the recent presence of positive thermal anomalies with temperatures in the range 110-200 K. Hot-spots such as Prometheus, Culann, Surya, and Tupan (to mention the most persistent) emit a great variety of gases, some of which will condense at Io's surface near their source regions. Associated fields of freshly condensed SO 2 are easily observed, and deposits of more refractory compounds with higher (e.g., S 8) or lower (e.g., NaCl) molecular weight must also be present (although their exact nature is unknown). Three different mechanisms of emission are proposed for the volatile compounds and supported by the distribution maps. These are (a) the interaction between flowing lava and preexisting volatile deposits on the surface, (b) direct degassing from the lava, an d (c) the eruption of a liquid aquifer from underground

  6. Gas

    1996-01-01

    The French government has decided to modify the conditions of extension of local natural gas authorities to neighbouring districts. The European Union is studying the conditions of internal gas market with the objective of more open markets although considering public service requirements

  7. Accelerated expansion of a universe containing a self-interacting Bose-Einstein gas

    Izquierdo, German; Besprosvany, Jaime, E-mail: german.izquierdo@gmail.co, E-mail: bespro@fisica.unam.m [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Circuito de la Investigacion CientIfica S/N, Ciudad Universitaria, CP 04510, Mexico, Distrito Federal (Mexico)

    2010-03-21

    Acceleration of the universe is obtained from a model of non-relativistic particles with a short-range attractive interaction, at low enough temperature to produce a Bose-Einstein condensate. Conditions are derived for negative-pressure behavior. In particular, we show that a phantom-accelerated regime at the beginning of the universe solves the horizon problem, consistently with nucleosynthesis.

  8. Consumer Behavior and Greenhouse Gas Emissions at the University of Rhode Island

    2009-12-31

    Of the 16,000 students at the University of Rhode Island, about 55% percent commute to campus. Between students, staff and faculty there could be up to 11,000 commuters at the University, most of which drive alone. A high volume of single-occupancy v...

  9. The MEG positron spectrometer

    Nishiguchi, Hajime

    2007-01-01

    We have been developing an innovative spectrometer for the MEG experiment at the Paul Scherrer Institute (PSI) in Switzerland. This experiment searches for a lepton flavour violating decay μ + →e + γ with a sensitivity of 10 -13 in order to explore the region predicted by supersymmetric extensions of the standard model. The MEG positron spectrometer consists of a specially designed superconducting solenoidal magnet with a highly graded field, an ultimate low-mass drift chamber system, and a precise time measuring counter system. This innovative positron spectrometer is described here focusing on the drift chamber system

  10. Development and analytical characterization of a Grimm-type glow discharge ion source operated with high gas flow rates and coupled to a mass spectrometer with high mass resolution

    Beyer, Claus; Feldmann, Ingo; Gilmour, Dave; Hoffmann, Volker; Jakubowski, Norbert

    2002-01-01

    A Grimm-type glow discharge ion source has been developed and was coupled to a commercial inductively coupled plasma mass spectrometer (ICP-MS) with high mass resolution (Axiom, ThermoElemental, Winsford, UK) by exchanging the front plate of the ICP-MS interface system only. In addition to high discharge powers of up to 70 W, which are typical for a Grimm-type design, this source could be operated with relative high gas flow rates of up to 240 ml min -1 . In combination with a high discharge voltage the signal intensities are reaching a constant level within the first 20 s after the discharge has started. An analytical characterization of this source is given utilizing a calibration using the steel standard reference material NIST 1261A-1265A. The sensitivity for the investigated elements measured with a resolution of 4000 is in the range of 500-6000 cps μg -1 g -1 , and a relative standard deviation (R.S.D.) of the measured isotope relative to Fe of less than 8% for the major and minor components of the sample has been achieved. Limits of detection at ng g -1 levels could be obtained

  11. Use of a hand-portable gas chromatograph-toroidal ion trap mass spectrometer for self-chemical ionization identification of degradation products related to O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX)

    Smith, Philip A., E-mail: Smith.Philip.A@dol.gov [Uniformed Services University of the Health Sciences, Department of Preventive Medicine and Biometrics, 4301 Jones Bridge Road, Bethesda, MD, 20814 (United States); Lepage, Carmela R. Jackson [Defence R and D Canada - Suffield, Box 400, Station Main, Medicine Hat, Alberta, T1A 8K6 (Canada); Savage, Paul B. [Brigham Young University, Department of Chemistry and Biochemistry, Provo, UT, 84602 (United States); Bowerbank, Christopher R.; Lee, Edgar D. [Torion Technologies Inc., 796 East Utah Valley Drive, Suite 200, American Fork, UT, 84003 (United States); Lukacs, Michael J. [Defence R and D Canada - Suffield, Box 400, Station Main, Medicine Hat, Alberta, T1A 8K6 (Canada)

    2011-04-01

    The chemical warfare agent O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX) and many related degradation products produce poorly diagnostic electron ionization (EI) mass spectra by transmission quadrupole mass spectrometry. Thus, chemical ionization (CI) is often used for these analytes. In this work, pseudomolecular ([M+H]{sup +}) ion formation from self-chemical ionization (self-CI) was examined for four VX degradation products containing the diisopropylamine functional group. A person-portable toroidal ion trap mass spectrometer with a gas chromatographic inlet was used with EI, and both fixed-duration and feedback-controlled ionization time. With feedback-controlled ionization, ion cooling (reaction) times and ion formation target values were varied. Evidence for protonation of analytes was observed under all conditions, except for the largest analyte, bis(diisopropylaminoethyl)disulfide which yielded [M+H]{sup +} ions only with increased fixed ionization or ion cooling times. Analysis of triethylamine-d{sub 15} provided evidence that [M+H]{sup +} production was likely due to self-CI. Analysis of a degraded VX sample where lengthened ion storage and feedback-controlled ionization time were used resulted in detection of [M+H]{sup +} ions for VX and several relevant degradation products. Dimer ions were also observed for two phosphonate compounds detected in this sample.

  12. Characterization of a microwave microstrip helium plasma with gas-phase sample introduction for the optical emission spectrometric determination of bromine, chlorine, sulfur and carbon using a miniaturized optical fiber spectrometer

    Pohl, Pawel; Zapata, Israel Jimenez; Amberger, Martin A.; Bings, Nicolas H.; Broekaert, Jose A.C.

    2008-01-01

    Continuous flow generation of Br 2 , Cl 2 and H 2 S coupled to a low-power 2.45 GHz microwave microstrip He plasma exiting from a capillary gas channel in a micro-fabricated sapphire wafer with microstrip lines has been used for the optical emission spectrometric determination of Br, Cl and S using a miniaturized optical fiber CCD spectrometer. Under optimized conditions, detection limits (3σ) of 330, 190 and 220 μg l -1 for Br, Cl and S, respectively, under the use of the Br II 478.5 nm, Cl I 439.0 nm and S I 469.0 nm lines were obtained and the calibration curves were found to be linear over 2 orders of magnitude. In addition, when introducing CO 2 and using the rotational line of the CN molecular band at 385.7 nm the detection limit for C was 4.6 μg l -1 . The procedure developed was found to be free from interferences from a number of metal cations and non-metal anions. Only the presence of CO 3 2- and CN - was found to cause severe spectral interferences as strong CN and C 2 molecular bands occurred as a result of an introduction of co-generated CO 2 and HCN into the plasma. With the procedure described Br, Cl and S could be determined at a concentration level of 10-30 mg l -1 with accuracy and precision better than 2%

  13. Use of a hand-portable gas chromatograph-toroidal ion trap mass spectrometer for self-chemical ionization identification of degradation products related to O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX)

    Smith, Philip A.; Lepage, Carmela R. Jackson; Savage, Paul B.; Bowerbank, Christopher R.; Lee, Edgar D.; Lukacs, Michael J.

    2011-01-01

    The chemical warfare agent O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX) and many related degradation products produce poorly diagnostic electron ionization (EI) mass spectra by transmission quadrupole mass spectrometry. Thus, chemical ionization (CI) is often used for these analytes. In this work, pseudomolecular ([M+H] + ) ion formation from self-chemical ionization (self-CI) was examined for four VX degradation products containing the diisopropylamine functional group. A person-portable toroidal ion trap mass spectrometer with a gas chromatographic inlet was used with EI, and both fixed-duration and feedback-controlled ionization time. With feedback-controlled ionization, ion cooling (reaction) times and ion formation target values were varied. Evidence for protonation of analytes was observed under all conditions, except for the largest analyte, bis(diisopropylaminoethyl)disulfide which yielded [M+H] + ions only with increased fixed ionization or ion cooling times. Analysis of triethylamine-d 15 provided evidence that [M+H] + production was likely due to self-CI. Analysis of a degraded VX sample where lengthened ion storage and feedback-controlled ionization time were used resulted in detection of [M+H] + ions for VX and several relevant degradation products. Dimer ions were also observed for two phosphonate compounds detected in this sample.

  14. Fractal analysis of the dark matter and gas distributions in the Mare-Nostrum universe

    Gaite, José

    2010-01-01

    We develop a method of multifractal analysis of N-body cosmological simulations that improves on the customary counts-in-cells method by taking special care of the effects of discreteness and large scale homogeneity. The analysis of the Mare-Nostrum simulation with our method provides strong evidence of self-similar multifractal distributions of dark matter and gas, with a halo mass function that is of Press-Schechter type but has a power-law exponent -2, as corresponds to a multifractal. Furthermore, our analysis shows that the dark matter and gas distributions are indistinguishable as multifractals. To determine if there is any gas biasing, we calculate the cross-correlation coefficient, with negative but inconclusive results. Hence, we develop an effective Bayesian analysis connected with information theory, which clearly demonstrates that the gas is biased in a long range of scales, up to the scale of homogeneity. However, entropic measures related to the Bayesian analysis show that this gas bias is small (in a precise sense) and is such that the fractal singularities of both distributions coincide and are identical. We conclude that this common multifractal cosmic web structure is determined by the dynamics and is independent of the initial conditions

  15. Electron-ion-x-ray spectrometer system

    Southworth, S.H.; Deslattes, R.D.; MacDonald, M.A.

    1993-01-01

    The authors describe a spectrometer system developed for electron, ion, and x-ray spectroscopy of gas-phase atoms and molecules following inner-shell excitation by tunable synchrotron radiation. The spectrometer has been used on beamline X-24A at the National Synchrotron Light Source for excitation-dependent studies of Ar L-shell and K-shell photoexcitation and vacancy decay processes. The instrumentation and experimental methods are discussed, and examples are given of electron spectra and coincidence spectra between electrons and fluorescent x-rays

  16. Digital positron annihilation spectrometer

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  17. Micro Plasma Spectrometer

    National Aeronautics and Space Administration — The purpose of this IRAD project is to develop a preliminary design elements of miniature electron and ion plasma spectrometers and supporting electronics, focusing...

  18. Fourier Transform Spectrometer System

    Campbell, Joel F. (Inventor)

    2014-01-01

    A Fourier transform spectrometer (FTS) data acquisition system includes an FTS spectrometer that receives a spectral signal and a laser signal. The system further includes a wideband detector, which is in communication with the FTS spectrometer and receives the spectral signal and laser signal from the FTS spectrometer. The wideband detector produces a composite signal comprising the laser signal and the spectral signal. The system further comprises a converter in communication with the wideband detector to receive and digitize the composite signal. The system further includes a signal processing unit that receives the composite signal from the converter. The signal processing unit further filters the laser signal and the spectral signal from the composite signal and demodulates the laser signal, to produce velocity corrected spectral data.

  19. An aircraft gas chromatograph–mass spectrometer System for Organic Fast Identification Analysis (SOFIA: design, performance and a case study of Asian monsoon pollution outflow

    E. Bourtsoukidis

    2017-12-01

    Full Text Available Volatile organic compounds (VOCs are important for global air quality and oxidation processes in the troposphere. In addition to ground-based measurements, the chemical evolution of such species during transport can be studied by performing in situ airborne measurements. Generally, aircraft instrumentation needs to be sensitive, robust and sample at higher frequency than ground-based systems while their construction must comply with rigorous mechanical and electrical safety standards. Here, we present a new System for Organic Fast Identification Analysis (SOFIA, which is a custom-built fast gas chromatography–mass spectrometry (GC-MS system with a time resolution of 2–3 min and the ability to quantify atmospheric mixing ratios of halocarbons (e.g. chloromethanes, hydrocarbons (e.g isoprene, oxygenated VOCs (acetone, propanal, butanone and aromatics (e.g. benzene, toluene from sub-ppt to ppb levels. The relatively high time resolution is the result of a novel cryogenic pre-concentration unit which rapidly cools (∼ 6 °C s−1 the sample enrichment traps to −140 °C, and a new chromatographic oven designed for rapid cooling rates (∼ 30 °C s−1 and subsequent thermal stabilization. SOFIA was installed in the High Altitude and Long Range Research Aircraft (HALO for the Oxidation Mechanism Observations (OMO campaign in August 2015, aimed at investigating the Asian monsoon pollution outflow in the tropical upper troposphere. In addition to a comprehensive instrument characterization we present an example monsoon plume crossing flight as a case study to demonstrate the instrument capability. Hydrocarbon, halocarbon and oxygenated VOC data from SOFIA are compared with mixing ratios of carbon monoxide (CO and methane (CH4, used to define the pollution plume. By using excess (ExMR and normalized excess mixing ratios (NEMRs the pollution could be attributed to two air masses of distinctly different origin, identified by back

  20. An aircraft gas chromatograph-mass spectrometer System for Organic Fast Identification Analysis (SOFIA): design, performance and a case study of Asian monsoon pollution outflow

    Bourtsoukidis, Efstratios; Helleis, Frank; Tomsche, Laura; Fischer, Horst; Hofmann, Rolf; Lelieveld, Jos; Williams, Jonathan

    2017-12-01

    Volatile organic compounds (VOCs) are important for global air quality and oxidation processes in the troposphere. In addition to ground-based measurements, the chemical evolution of such species during transport can be studied by performing in situ airborne measurements. Generally, aircraft instrumentation needs to be sensitive, robust and sample at higher frequency than ground-based systems while their construction must comply with rigorous mechanical and electrical safety standards. Here, we present a new System for Organic Fast Identification Analysis (SOFIA), which is a custom-built fast gas chromatography-mass spectrometry (GC-MS) system with a time resolution of 2-3 min and the ability to quantify atmospheric mixing ratios of halocarbons (e.g. chloromethanes), hydrocarbons (e.g isoprene), oxygenated VOCs (acetone, propanal, butanone) and aromatics (e.g. benzene, toluene) from sub-ppt to ppb levels. The relatively high time resolution is the result of a novel cryogenic pre-concentration unit which rapidly cools (˜ 6 °C s-1) the sample enrichment traps to -140 °C, and a new chromatographic oven designed for rapid cooling rates (˜ 30 °C s-1) and subsequent thermal stabilization. SOFIA was installed in the High Altitude and Long Range Research Aircraft (HALO) for the Oxidation Mechanism Observations (OMO) campaign in August 2015, aimed at investigating the Asian monsoon pollution outflow in the tropical upper troposphere. In addition to a comprehensive instrument characterization we present an example monsoon plume crossing flight as a case study to demonstrate the instrument capability. Hydrocarbon, halocarbon and oxygenated VOC data from SOFIA are compared with mixing ratios of carbon monoxide (CO) and methane (CH4), used to define the pollution plume. By using excess (ExMR) and normalized excess mixing ratios (NEMRs) the pollution could be attributed to two air masses of distinctly different origin, identified by back-trajectory analysis. This work

  1. A Tale of Energy Transition and Tension: The Incomplete Universalization of the Natural Gas Grid in Istanbul

    Arik, Elvan

    2013-01-01

    Available studies on natural gas networks have so far made little contribution to an understanding of changes in urban management in emerging cities. However, the development of such energy systems, considered as cleaner and more efficient compared to previous systems based primarily on the use of traditional fuels (wood, coal, LPG, biofuels) leads these cities into an energy transition. This process is firstly characterized by the introduction of a new energy resource that then involves changes in certain domestic practices (such as, in our case study, heating and culinary practices). Focusing on the case of the development of the natural gas network in Istanbul, this paper studies the tensions inherent in this transformation. Socio-political and territorial analysis of the deployment of this network, which allows us to evaluate the actual universalization of the service, allows us to turn our attention away from the issue of access to the infrastructure and toward the concrete domestic uses of the service

  2. Incident at university research facility - melt down of gas chromatograph evaporation block and failure of a passive safety barrier

    Jensen, Niels; Jørgensen, Sten Bay

    2014-01-01

    Two incidents are described highlighting the importance of process hazard analysis in university laboratories. In the first incident, an online gas chromatograph (GC) was being developed. A complete meltdown of the heating blog was experienced during testing because the PC had failed to turn off...... the heating of the evaporation circuit. There had been no design review of the GC, nor any code review of the software controlling the GC. Neither had there been any management of change review for the introduction of the GC in the pilot plant environment, and so the GC had been introduced without any...

  3. Early Gas Stripping as the Origin of the Darkest Galaxies in the Universe

    Mayer, Lucio; /Zurich, ETH /Zurich U.; Kazantzidis, Stelios; /KIPAC, Menlo Park /KICP, Chicago; Mastropietro, Chiara; /Munich U. Observ.; Wadsley, James; /McMaster U.

    2007-02-28

    The known galaxies most dominated by dark matter (Draco, Ursa Minor and Andromeda IX) are satellites of the Milky Way and the Andromeda galaxies. They are members of a class of faint galaxies, devoid of gas, known as dwarf spheroidals, and have by far the highest ratio of dark to luminous matter. None of the models proposed to unravel their origin can simultaneously explain their exceptional dark matter content and their proximity to a much larger galaxy. Here we report simulations showing that the progenitors of these galaxies were probably gas-dominated dwarf galaxies that became satellites of a larger galaxy earlier than the other dwarf spheroidals. We find that a combination of tidal shocks and ram pressure swept away the entire gas content of such progenitors about ten billion years ago because heating by the cosmic ultraviolet background kept the gas loosely bound: a tiny stellar component embedded in a relatively massive dark halo survived until today. All luminous galaxies should be surrounded by a few extremely dark-matter-dominated dwarf spheroidal satellites, and these should have the shortest orbital periods among dwarf spheroidals because they were accreted early.

  4. Incident at university research facility - pressure testing of gas hydrate cell

    Jensen, Niels; Jørgensen, Sten Bay

    2014-01-01

    A master student designed a cell for observing the development of gas hydrates as conditions in the cell were changed. The supervisor asked for a pressure test of the cell before the experiments started. The student chose-to perform the pressure test using compressed air and this resulted in one...

  5. MASS-SAT: Matter-antimatter space spectrometer on satellite

    Basini, G; Massimo Brancaccio, F; Ricci, M; Bocciolini, M; Spillantini, P; Wang, Y F; Bongiorno, F; de Pascale, M P; Morselli, A; Picozza, P; de Marzo, C; Erriquez, O; Barbiellini, G; Vacchi, A; Galeotti, P; Ballocchi, G; Simon, M; Carlson, P; Goret, P; Golden, R L

    The MASS-SAT Experiment (Matter-Antimatter Space Spectrometer on SATellite) presented here is conceived to search for an experimental answer to many open problems related to both Astrophysics and Physics, through the detection of positrons, antiprotons, nuclei and, overall, antinuclei if they exist. Among these problems there are the hypothesized presence of antigalaxies in the Universe (the matter-antimatter symmetry problem), the existence of black holes as possible antiproton sources (the Hawking effect), the existence of photinos as antiproton sources (related to the dark-matter problem), the understanding of the mechanism of cosmic-ray acceleration in the interstellar medium, the determination of the relative abundancies of isotopes in cosmic rays and many others. The choice of an orbit expecially appropriate for that (geostationary or polar orbit) as well as the choice of an apparatus composed only of solid-state detectors and permanent magnets (no gas and no liquid helium on board, avoiding complexity ...

  6. Multichannel Dynamic Fourier-Transform IR Spectrometer

    Balashov, A. A.; Vaguine, V. A.; Golyak, Il. S.; Morozov, A. N.; Khorokhorin, A. I.

    2017-09-01

    A design of a multichannel continuous scan Fourier-transform IR spectrometer for simultaneous recording and analysis of the spectral characteristics of several objects is proposed. For implementing the design, a multi-probe fiber is used, constructed from several optical fibers connected into a single optical connector and attached at the output of the interferometer. The Fourier-transform spectrometer is used as a signal modulator. Each fiber is individually mated with an investigated sample and a dedicated radiation detector. For the developed system, the radiation intensity of the spectrometer is calculated from the condition of the minimum spectral resolution and parameters of the optical fibers. Using the proposed design, emission spectra of a gas-discharge neon lamp have been recorded using a single fiber 1 mm in diameter with a numerical aperture NA = 0.22.

  7. Fabrication of the superferric cyclotron gas-stopper magnet at NSCL at Michigan state university

    Chouhan, S S; Bollen, G; DeKamp, J; Green, M A; Magsig, C; Zeller, A F; Lawton, D; Morrissey, D J; Ottarson, J; Schwarz, S

    2014-01-01

    The magnet for the cyclotron gas stopper is a newly designed, large warm-iron superconducting cyclotron sector gradient dipole. The maximum field in the centre (gap = 0.18 m) is 2.7 T. The outer diameter of magnet yoke is 4.0 m, with a pole radius of 1.1 m and B * ρ = 1.8 T m. The fabrication and assembly of the iron return yoke and twelve pole pieces is complete. Separate coils are mounted on the return yokes that have a total mass of about 167 metric tons of iron. This paper illustrates the design and the fabrication process for the cyclotron gas-stopper magnet that is being fabricated at MSU.

  8. Universal gas metal arc welding - a cost-effective and low dilution surfacing process

    Shahi, AS.; Pandey, Sunil

    2006-01-01

    This paper describes the use of a new variant of the gas metal arc welding (GMAW) process, termed u niversal gas metal arc welding (UGMAW), for the weld cladding of low carbon steels with stainless steel. The experimental work included single layer cladding of 12 mm thick low carbon steel with austenitic stainless steel 316L solid filler wire of 1.14 mm diameter. Low dilution conditions were employed using both mechanised GMAW and UGMAW processes. Metallurgical aspects of the as welded overlays were studied to evaluate the suitability of these processes for service conditions. It was found that UGMAW claddings contained higher ferrite content; higher concentrations of chromium, nickel and molybdenum; and lower carbon content compared to GMAW claddings. As a result, the UGMAW overlays exhibited superior mechanical and corrosion resistance properties. The findings of this study establish that the new process is technically superior and results in higher productivity, justifying its use for low cost surfacing applications

  9. Characterization of a microwave microstrip helium plasma with gas-phase sample introduction for the optical emission spectrometric determination of bromine, chlorine, sulfur and carbon using a miniaturized optical fiber spectrometer

    Pohl, Pawel; Zapata, Israel Jimenez; Amberger, Martin A.; Bings, Nicolas H. [Universitaet Hamburg, Institut fuer Anorganische und Angewandte Chemie, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany); Broekaert, Jose A.C. [Universitaet Hamburg, Institut fuer Anorganische und Angewandte Chemie, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany)], E-mail: jose.broekaert@chemie.uni-hamburg.de

    2008-03-15

    Continuous flow generation of Br{sub 2}, Cl{sub 2} and H{sub 2}S coupled to a low-power 2.45 GHz microwave microstrip He plasma exiting from a capillary gas channel in a micro-fabricated sapphire wafer with microstrip lines has been used for the optical emission spectrometric determination of Br, Cl and S using a miniaturized optical fiber CCD spectrometer. Under optimized conditions, detection limits (3{sigma}) of 330, 190 and 220 {mu}g l{sup -1} for Br, Cl and S, respectively, under the use of the Br II 478.5 nm, Cl I 439.0 nm and S I 469.0 nm lines were obtained and the calibration curves were found to be linear over 2 orders of magnitude. In addition, when introducing CO{sub 2} and using the rotational line of the CN molecular band at 385.7 nm the detection limit for C was 4.6 {mu}g l{sup -1}. The procedure developed was found to be free from interferences from a number of metal cations and non-metal anions. Only the presence of CO{sub 3}{sup 2-} and CN{sup -} was found to cause severe spectral interferences as strong CN and C{sub 2} molecular bands occurred as a result of an introduction of co-generated CO{sub 2} and HCN into the plasma. With the procedure described Br, Cl and S could be determined at a concentration level of 10-30 mg l{sup -1} with accuracy and precision better than 2%.

  10. Universe

    2009-01-01

    The Universe, is one book in the Britannica Illustrated Science Library Series that is correlated to the science curriculum in grades 5-8. The Britannica Illustrated Science Library is a visually compelling set that covers earth science, life science, and physical science in 16 volumes.  Created for ages 10 and up, each volume provides an overview on a subject and thoroughly explains it through detailed and powerful graphics-more than 1,000 per volume-that turn complex subjects into information that students can grasp.  Each volume contains a glossary with full definitions for vocabulary help and an index.

  11. Temperature and coupling dependence of the universal contact intensity for an ultracold Fermi gas

    Palestini, F.; Perali, A.; Pieri, P.; Strinati, G. C.

    2010-01-01

    Physical properties of an ultracold Fermi gas in the temperature-coupling phase diagram can be characterized by the contact intensity C, which enters the pair-correlation function at short distances and describes how the two-body problem merges into its surrounding. We show that the local order established by pairing fluctuations about the critical temperature T c of the superfluid transition considerably enhances the contact C in a temperature range where pseudogap phenomena are maximal. Our ab initio results for C in a trap compare well with recently available experimental data over a wide coupling range. An analysis is also provided for the effects of trap averaging on C.

  12. Warm intermediate inflationary Universe model in the presence of a generalized Chaplygin gas

    Herrera, Ramon [Pontificia Universidad Catolica de Valparaiso, Instituto de Fisica, Valparaiso (Chile); Videla, Nelson [Universidad de Chile, Departamento de Fisica, FCFM, Santiago (Chile); Olivares, Marco [Universidad Diego Portales, Facultad de Ingenieria, Santiago (Chile)

    2016-01-15

    A warm intermediate inflationary model in the context of generalized Chaplygin gas is investigated. We study this model in the weak and strong dissipative regimes, considering a generalized form of the dissipative coefficient Γ = Γ(T,φ), and we describe the inflationary dynamics in the slow-roll approximation. We find constraints on the parameters in our model considering the Planck 2015 data, together with the condition for warm inflation T > H, and the conditions for the weak and strong dissipative regimes. (orig.)

  13. Universal Properties of a Trapped Two-Component Fermi Gas at Unitarity

    Blume, D.; Stecher, J. von; Greene, Chris H.

    2007-01-01

    We treat the trapped two-component Fermi system, in which unlike fermions interact through a two-body short-range potential having no bound state but an infinite scattering length. By accurately solving the Schroedinger equation for up to N=6 fermions, we show that no many-body bound states exist other than those bound by the trapping potential, and we demonstrate unique universal properties of the system: Certain excitation frequencies are separated by 2(ℎ/2π)ω, the wave functions agree with analytical predictions and a virial theorem is fulfilled. Further calculations up to N=30 determine the excitation gap, an experimentally accessible universal quantity, and it agrees with recent predictions based on a density functional approach

  14. Imaging spectrometers for atmosphere monitoring

    Reinert, Thido; Bovensmann, Heinrich; Münzenmayer, Ralf; Weiss, Stefan; Posselt, Winfried

    2017-11-01

    Atmospheric monitoring missions aim at products like O3, H2O, NO2, SO2, BrO, CH4, CO, CO2 as well as aerosols and cloud information. Depending on the application area (Ozone Monitoring, Green House Gas Monitoring, Tropospheric Composition and Air Quality, Chemistry Climate Interaction etc.) total or tropospheric columns as well as profile information is required. The user community of these data as well as their central requirements w.r.t. the payload aspects will be described. A large range of relevant passive instrument types is available, in particular imaging spectrometer, sounder and polarisation measuring systems in the UV-VIS, SWIR and TIR spectral range. Differences between instruments for dedicated missions are highlighted and evolution of requirements is explained, also in comparison with relevant existing instrumentation partly in orbit today. Aspects of technology roadmaps for instrument implementation as well as synergetic effects of instrument combinations and according mission scopes are discussed.

  15. Cyclotrons as mass spectrometers

    Clark, D.J.

    1984-04-01

    The principles and design choices for cyclotrons as mass spectrometers are described. They are illustrated by examples of cyclotrons developed by various groups for this purpose. The use of present high energy cyclotrons for mass spectrometry is also described. 28 references, 12 figures

  16. Miniature Raman spectrometer development

    Bonvallet, Joseph; Auz, Bryan; Rodriguez, John; Olmstead, Ty

    2018-02-01

    The development of techniques to rapidly identify samples ranging from, molecule and particle imaging to detection of high explosive materials, has surged in recent years. Due to this growing want, Raman spectroscopy gives a molecular fingerprint, with no sample preparation, and can be done remotely. These systems can be small, compact, lightweight, and with a user interface that allows for easy use and sample identification. Ocean Optics Inc. has developed several systems that would meet all these end user requirements. This talk will describe the development of different Ocean Optics Inc miniature Raman spectrometers. The spectrometer on a phone (SOAP) system was designed using commercial off the shelf (COTS) components, in a rapid product development cycle. The footprint of the system measures 40x40x14 mm (LxWxH) and was coupled directly to the cell phone detector camera optics. However, it gets roughly only 40 cm-1 resolution. The Accuman system is the largest (290x220X100 mm) of the three, but uses our QEPro spectrometer and get 7-11 cm-1 resolution. Finally, the HRS-30 measuring 165x85x40 mm is a combination of the other two systems. This system uses a modified EMBED spectrometer and gets 7-12 cm-1 resolution. Each of these units uses a peak matching algorithm that then correlates the results to the pre-loaded and customizable spectral libraries.

  17. Magnetic spectrometer Grand Raiden

    Fujiwara, M.; Akimune, H.; Daito, I.; Fujimura, H.; Fujita, Y.; Hatanaka, K.; Ikegami, H.; Katayama, I.; Nagayama, K.; Matsuoka, N.; Morinobu, S.; Noro, T.; Yoshimura, M.; Sakaguchi, H.; Sakemi, Y.; Tamii, A.; Yosoi, M.

    1999-01-01

    A high-resolution magnetic spectrometer called 'Grand Raiden' is operated at the RCNP ring cyclotron facility in Osaka for nuclear physics studies at intermediate energies. This magnetic spectrometer has excellent ion-optical properties. In the design of the spectrometer, the second-order dispersion matching condition has been taken into account, and almost all the aberration terms such as (x vertical bar θ 3 ), (x vertical bar θφ 2 ), (x vertical bar θ 2 δ) and (x vertical bar θδ 2 ) in a third-order matrix calculation are optimized. A large magnetic rigidity of the spectrometer (K = 1400 MeV) gives a great advantage to measure the charge-exchange ( 3 He, t) reactions at 450 MeV. The ability of the high-resolution measurement has been demonstrated. Various coincidence measurements are performed to study the nuclear structures of highly excited states through decay properties of nuclear levels following nuclear reactions at intermediate energies

  18. Microprocessor monitored Auger spectrometer

    Sapin, Michel; Ghaleb, Dominique; Pernot, Bernard.

    1982-05-01

    The operation of an Auger spectrometer, used for studying surface impurity diffusion, has been fully automatized with the help of a microprocessor. The characteristics, performance and practical use of the system are described together with the main advantage for the experimentator [fr

  19. The Omega spectrometer

    1972-01-01

    The Omega spectrometer which came into action during the year. An array of optical spark chambers can be seen withdrawn from the magnet aperture. In the 'igloo' above the magnet is located the Plumbicon camera system which collects information from the spark chambers.

  20. Heat of vaporization spectrometer

    Edwards, D. Jr.

    1978-01-01

    Multilayer desorption measurements of various substances adsorbed on a stainless steel substrate are found to exhibit desorption profiles consistent with a zeroth order desorption model. The singleness of the desorption transients together with their narrow peak widths makes the technique ideally suited for a heat of vaporization spectrometer for either substance analysis or identification

  1. Speckle-based spectrometer

    Chakrabarti, Maumita; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2015-01-01

    A novel spectrometer concept is analyzed and experimentally verified. The method relies on probing the speckle displacement due to a change in the incident wavelength. A rough surface is illuminated at an oblique angle, and the peak position of the covariance between the speckle patterns observed...

  2. Electron volt neutron spectrometers

    Pietropaolo, A.; Senesi, R.

    2011-01-01

    The advent of pulsed neutron sources has made available intense fluxes of epithermal neutrons (500 meV ≤E≤100 eV ). The possibility to open new investigations on condensed matter with eV neutron scattering techniques, is related to the development of methods, concepts and devices that drive, or are inspired by, emerging studies at this energy scale. Electron volt spectrometers have undergone continuous improvements since the construction of the first prototype instruments, but in the last decade major breakthroughs have been accomplished in terms of resolution and counting statistics, leading, for example, to the direct measurement of the proton 3-D Born–Oppenheimer potential in any material, or to quantitatively probe nuclear quantum effects in hydrogen bonded systems. This paper reports on the most effective methods and concepts for energy analysis and detection, as well as devices for the optimization of electron volt spectrometers for different applications. This is set in the context of the progress made up to date in instrument development. Starting from early stages of development of the technique, particular emphasis will be given to the Vesuvio eV spectrometer at the ISIS neutron source, the first spectrometer where extensive scientific, as well as research and development programmes have been carried out. The potential offered by this type of instrumentation, from single particle excitations to momentum distribution studies, is then put in perspective into the emerging fields of eV spectroscopy applied to cultural heritages and neutron irradiation effects in electronics. - Highlights: ► Neutron spectrometers at eV energies. ► Methods and techniques for eV neutrons counting at spallation sources. ► Scattering, imaging and radiation hardness tests with multi-eV neutrons.

  3. Gamma-ray spectrometer utilizing xenon at high pressure

    Smith, G.C.; Mahler, G.J.; Yu, B.; Kane, W.R.; Markey, J.K.

    1994-01-01

    A prototype gamma-ray spectrometer utilizing xenon gas near the critical point (166 degrees C, 58 atm) is under development. The spectrometer will function as a room-temperature ionization chamber detecting gamma rays in the energy range 100 keV2 MeV, with an energy resolution intermediate between semiconductor (Ge) and scintillation (NaI) spectrometers. The energy resolution is superior to that of a NaI scintillation spectrometer by a substantial margin (approximately a factor 5), and accordingly, much more information can be extracted from a given gamma-ray spectrum. Unlike germanium detectors, the spectrometer possesses the capability for sustained operation under ambient temperature conditions without a requirement for liquid nitrogen

  4. How to characterize the efficiency of policies for reducing greenhouse gas emissions? A method of analysis in an uncertain universe

    Amant, Stephane

    2011-01-01

    For ADEME (the French Agence de l'Environnement et de la Maitrise de l'Energie), Carbone 4, a consulting firm, has developed several tools that apply a methodology for assessing the efficiency of policies for reducing greenhouse gas emissions. This methodology is based on two criteria: the 'full cost per ton of avoided CO 2 equivalent' and the 'potential of avoided emissions'. It is original in that it compares measurements in quite different socioeconomic contexts and thus yields elements that are useful for making choices in an uncertain universe, as shall be increasingly necessary. This methodology brings to light the key factors determining a measure's efficiency and thus identifies the conditions for its success or failure. It is a precious tool for decision-making

  5. Time-of-flight mass spectrometer

    Ivanov, M.A.; Kozlov, B.N.; Mamyrin, B.A.; Shmikk, D.V.; Shebelin, V.G.

    1981-01-01

    A time-of-flight mass spectrometer containing a pulsed ion source with an electron gun and two electrodes limiting ionization range, drift space and ion acceptor, is described. To expand functional possibilities, a slot collimator of the gas stream, two quantum generators and two diaphragms for the inlet of quantum generator radiation located on both sides of the ion source, are introduced in the ion source. The above invention enables to study details of the complex interaction process of laser radiation with molecules of the gas stream, which is actual for laser isotope separation

  6. The use of direct geometry spectrometers in molecular spectroscopy

    Parker, Stewart F; Ramirez-Cuesta, Anibal J; Albers, Peter W; Lennon, David

    2014-01-01

    The advantages and disadvantages of the use of direct geometry spectrometers for molecular spectroscopy and catalysis studies are described. We show that both direct and indirect geometry INS spectrometers are important tools for the study of industrially relevant areas such as catalysis, proton conductors and gas separation. We propose a novel hybrid instrument, Cerberus, that would offer high sensitivity and high-to-reasonable resolution across the entire 'mid-infrared' spectral range that would effectively advance research in these areas

  7. Inflation of the early cold Universe filled with a nonlinear scalar field and a nonideal relativistic Fermi gas

    Pashitskii, E. A., E-mail: pashitsk@iop.kiev.ua; Pentegov, V. I., E-mail: pentegov@iop.kiev.ua [National Academy of Sciences of Ukraine, Institute of Physics (Ukraine)

    2017-03-15

    We consider a possible scenario for the evolution of the early cold Universe born from a fairly large quantum fluctuation in a vacuum with a size a{sub 0} ≫ l{sub P} (where l{sub P} is the Planck length) and filled with both a nonlinear scalar field φ, whose potential energy density U(φ) determines the vacuum energy density λ, and a nonideal Fermi gas with short-range repulsion between particles, whose equation of state is characterized by the ratio of pressure P(n{sub F}) to energy density ε(n{sub F}) dependent on the number density of fermions n{sub F}. As the early Universe expands, the dimensionless quantity ν(n{sub F}) = P(n{sub F})/ε(n{sub F}) decreases with decreasing n{sub F} from its maximum value ν{sub max} = 1 for n{sub F} → ∞ to zero for n{sub F} → 0. The interaction of the scalar and gravitational fields, which is characterized by a dimensionless constant ξ, is proportional to the scalar curvature of four-dimensional space R = κ[3P(n{sub F})–ε(n{sub F})–4λ] (where κ is Einstein’s gravitational constant), and contains terms both quadratic and linear in φ. As a result, the expanding early Universe reaches the point of first-order phase transition in a finite time interval at critical values of the scalar curvature R = R{sub c} =–μ{sup 2}/ξ and radius a{sub c} ≫ a{sub 0}. Thereafter, the early closed Universe “rolls down” from the flat inflection point of the potential U(φ) to the zero potential minimum in a finite time. The release of the total potential energy of the scalar field in the entire volume of the expanding Universe as it “rolls down” must be accompanied by the production of a large number of massive particles and antiparticles of various kinds, whose annihilation plays the role of the Big Bang. We also discuss the fundamental nature of Newton’ gravitational constant G{sub N}.

  8. Inflation of the early cold Universe filled with a nonlinear scalar field and a nonideal relativistic Fermi gas

    Pashitskii, E. A.; Pentegov, V. I.

    2017-01-01

    We consider a possible scenario for the evolution of the early cold Universe born from a fairly large quantum fluctuation in a vacuum with a size a_0 ≫ l_P (where l_P is the Planck length) and filled with both a nonlinear scalar field φ, whose potential energy density U(φ) determines the vacuum energy density λ, and a nonideal Fermi gas with short-range repulsion between particles, whose equation of state is characterized by the ratio of pressure P(n_F) to energy density ε(n_F) dependent on the number density of fermions n_F. As the early Universe expands, the dimensionless quantity ν(n_F) = P(n_F)/ε(n_F) decreases with decreasing n_F from its maximum value ν_m_a_x = 1 for n_F → ∞ to zero for n_F → 0. The interaction of the scalar and gravitational fields, which is characterized by a dimensionless constant ξ, is proportional to the scalar curvature of four-dimensional space R = κ[3P(n_F)–ε(n_F)–4λ] (where κ is Einstein’s gravitational constant), and contains terms both quadratic and linear in φ. As a result, the expanding early Universe reaches the point of first-order phase transition in a finite time interval at critical values of the scalar curvature R = R_c =–μ"2/ξ and radius a_c ≫ a_0. Thereafter, the early closed Universe “rolls down” from the flat inflection point of the potential U(φ) to the zero potential minimum in a finite time. The release of the total potential energy of the scalar field in the entire volume of the expanding Universe as it “rolls down” must be accompanied by the production of a large number of massive particles and antiparticles of various kinds, whose annihilation plays the role of the Big Bang. We also discuss the fundamental nature of Newton’ gravitational constant G_N.

  9. Wide band ENDOR spectrometer

    Mendonca Filho, C.

    1973-01-01

    The construction of an ENDOR spectrometer operating from 0,5 to 75 MHz within a single band, with ore Klystron and homodine detection, and no fundamental changes on the electron spin resonance spectrometer was described. The ENDOR signal can be detected both by amplitude modulation of the frequency field, or direct detection of the ESR output, which is taken to a signal analyser. The signal-to-noise ratio is raised by averaging rather than filtering avoiding the use of long time constants, providing natural line widths. The experimental apparatus and the spectra obtained are described. A discussion, relating the ENDOR line amplitudes with the experimental conditions is done and ENDOR mechanism, in which there is a relevant presence of cross relaxation is proposed

  10. The OPERA magnetic spectrometer

    Ambrosio, M; Dusini, S; Dulach, B; Fanin, C; Felici, G; Corso, F D; Garfagnini, A; Grianti, F; Gustavino, C; Monacelli, P; Paoloni, A; Stanco, L; Spinetti, M; Terranova, F; Votano, L

    2004-01-01

    The OPERA neutrino oscillation experiment foresees the construction of two magnetized iron spectrometers located after the lead-nuclear emulsion targets. The magnet is made up of two vertical walls of rectangular cross section connected by return yokes. The particle trajectories are measured by high precision drift tubes located before and after the arms of the magnet. Moreover, the magnet steel is instrumented with Resistive Plate Chambers that ease pattern recognition and allow a calorimetric measurement of the hadronic showers. In this paper we review the construction of the spectrometers. In particular, we describe the results obtained from the magnet and RPC prototypes and the installation of the final apparatus at the Gran Sasso laboratories. We discuss the mechanical and magnetic properties of the steel and the techniques employed to calibrate the field in the bulk of the magnet. Moreover, results of the tests and issues concerning the mass production of the Resistive Plate Chambers are reported. Final...

  11. Artificial intelligence for geologic mapping with imaging spectrometers

    Kruse, F. A.

    1993-01-01

    This project was a three year study at the Center for the Study of Earth from Space (CSES) within the Cooperative Institute for Research in Environmental Science (CIRES) at the University of Colorado, Boulder. The goal of this research was to develop an expert system to allow automated identification of geologic materials based on their spectral characteristics in imaging spectrometer data such as the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This requirement was dictated by the volume of data produced by imaging spectrometers, which prohibits manual analysis. The research described is based on the development of automated techniques for analysis of imaging spectrometer data that emulate the analytical processes used by a human observer. The research tested the feasibility of such an approach, implemented an operational system, and tested the validity of the results for selected imaging spectrometer data sets.

  12. ALICE photon spectrometer crystals

    Maximilien Brice

    2006-01-01

    Members of the mechanical assembly team insert the last few crystals into the first module of ALICE's photon spectrometer. These crystals are made from lead-tungstate, a crystal as clear as glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, emitting a flash of light allowing the energy of photons, electrons and positrons to be measured.

  13. Magnetic spectrometer control system

    Lecca, L.A.; Di Paolo, Hugo; Fernandez Niello, Jorge O.; Marti, Guillermo V; Pacheco, Alberto J.; Ramirez, Marcelo

    2003-01-01

    The design and implementation of a new computerized control system for the several devices of the magnetic spectrometer at TANDAR Laboratory is described. This system, as a main difference from the preexisting one, is compatible with almost any operating systems of wide spread use available in PC. This allows on-line measurement and control of all signals from any terminal of a computer network. (author)

  14. Polarized neutron spectrometer

    Abov, Yu.G.; Novitskij, V.V.; Alfimenkov, V.P.; Galinskij, E.M.; Mareev, Yu.D.; Pikel'ner, L.B.; Chernikov, A.N.; Lason', L.; Tsulaya, V.M.; Tsulaya, M.I.

    2000-01-01

    The polarized neutron spectrometer, intended for studying the interaction of polarized neutrons with nuclei and condensed media in the area of energies from thermal up to several electron-volt, is developed at the IBR-2 reactor (JINR, Dubna). Diffraction on the Co(92%)-Fe(8%) magnetized monocrystals is used for the neutron polarization and polarization analysis. The neutron polarization within the whole energy range equals ∼ 95% [ru

  15. Development of Neutron Spectrometer

    Lee, Chang Hee; Lee, J. S.; Seong, B. S. (and others)

    2007-06-15

    Neutron spectrometers which are used in the basic researches such as physics, chemistry and materials science and applied in the industry were developed at the horizontal beam port of HANARO reactor. In addition, the development of core components for neutron scattering and the upgrade of existing facilities are also performed. The vertical neutron reflectometer was fabricated and installed at ST3 beam port. The performance test of the reflectometer was completed and the reflectometer was opened to users. The several core parts and options were added in the polarized neutron spectrometer. The horizontal neutron reflectometer from Brookhaven National Laboratory was moved to HANARO and installed, and the performance of the reflectometer was examined. The HIPD was developed and the performance test was completed. The base shielding for TAS was fabricated. The soller collimator, Cu mosaic monochromator, Si BPC monochromator and position sensitive detector were developed and applied in the neutron spectrometer as part of core component development activities. In addition, the sputtering machine for mirror device are fabricated and the neutron mirror is made using the sputtering machine. The FCD was upgraded and the performance of the FCD are improved over the factor of 10. The integration and upgrade of the neutron detection system were also performed.

  16. Discrimination of bacteria by rapid sensing their metabolic volatiles using an aspiration-type ion mobility spectrometer (a-IMS) and gas chromatography-mass spectrometry GC-MS.

    Ratiu, Ileana Andreea; Bocos-Bintintan, Victor; Patrut, Adrian; Moll, Victor Hugo; Turner, Matthew; Thomas, C L Paul

    2017-08-22

    The objective of our study was to investigate whether one may quickly and reliably discriminate different microorganism strains by direct monitoring of the headspace atmosphere above their cultures. Headspace samples above a series of in vitro bacterial cultures were directly interrogated using an aspiration type ion mobility spectrometer (a-IMS), which produced distinct profiles ("fingerprints") of ion currents generated simultaneously by the detectors present inside the ion mobility cell. Data processing and analysis using principal component analysis showed net differences in the responses produced by volatiles emitted by various bacterial strains. Fingerprint assignments were conferred on the basis of product ion mobilities; ions of differing size and mass were deflected in a different degree upon their introduction of a transverse electric field, impacting finally on a series of capacitors (denominated as detectors, or channels) placed in a manner analogous to sensor arrays. Three microorganism strains were investigated - Escherichia coli, Bacillus subtilis and Staphylococcus aureus; all strains possess a relatively low pathogenic character. Samples of air with a 5 cm 3 volume from the headspace above the bacterial cultures in agar growth medium were collected using a gas-tight chromatographic syringe and injected inside the closed-loop pneumatic circuit of the breadboard a-IMS instrument model ChemPro-100i (Environics Oy, Finland), at a distance of about 1 cm from the ionization source. The resulting chemical fingerprints were produced within two seconds from the moment of injection. The sampling protocol involved to taking three replicate samples from each of 10 different cultures for a specific strain, during a total period of 72 h after the initial incubation - at 24, 48 and 72 h, respectively. Principal component analysis (PCA) was used to discriminate between the IMS fingerprints. PCA was found to successfully discriminate between bacteria at three

  17. Silicon Microleaks for Inlets of Mass Spectrometers

    Harpold, Dan; Hasso, Niemann; Jamieson, Brian G.; Lynch, Bernard A.

    2009-01-01

    Microleaks for inlets of mass spectrometers used to analyze atmospheric gases can be fabricated in silicon wafers by means of photolithography, etching, and other techniques that are commonly used in the manufacture of integrated circuits and microelectromechanical systems. The microleaks serve to limit the flows of the gases into the mass-spectrometer vacuums to specified very small flow rates consistent with the capacities of the spectrometer vacuum pumps. There is a need to be able to precisely tailor the dimensions of each microleak so as to tailor its conductance to a precise low value. (As used here, "conductance" signifies the ratio between the rate of flow in the leak and the pressure drop from the upstream to the downstream end of the leak.) To date, microleaks have been made, variously, of crimped metal tubes, pulled glass tubes, or frits. Crimped-metal and pulled-glass-tube microleaks cannot readily be fabricated repeatably to precise dimensions and are susceptible to clogging with droplets or particles. Frits tend to be differentially chemically reactive with various gas constituents and, hence, to distort the gas mixtures to be analyzed. The present approach involving microfabrication in silicon largely overcomes the disadvantages of the prior approaches.

  18. Direct gas injection method: A simple modification to an elemental analyzer/isotope ratio mass spectrometer for stable isotope analysis of N and C from N2O and CO2 gases in nanomolar concentrations

    A simple modification to the Elemental Analyzer coupled to Isotope Ratio Mass-Spectrometer (EA-IRMS) setup is described. This modification allows the users to measure nitrous oxide (N2O) and carbon dioxide (CO2) by injecting the gases directly into an online injector placed befor...

  19. Cryogenic system for a superconducting spectrometer

    Porter, J.

    1983-03-01

    The Heavy Ion Spectrometer System (HISS) relies upon superconducting coils of cryostable, pool boiling design to provide a maximum particle bending field of 3 tesla. This paper describes the cryogenic facility including helium refrigeration, gas management, liquid nitrogen system, and the overall control strategy. The system normally operates with a 4 K heat load of 150 watts; the LN 2 circuits absorb an additional 4000 watts. 80K intercept control is by an LSI 11 computer. Total available refrigeration at 4K is 400 watts using reciprocating expanders at the 20K and 4K level. The minicomputer has the capability of optimizing overall utility input cost by varying operating points. A hybrid of pneumatic, analog, and digital control is successful in providing full time unattended operation. The 7m diameter magnet/cryostat assembly is rotatable through 180 degrees to provide a variety of spectrometer orientations

  20. MEMS tunable grating micro-spectrometer

    Tormen, Maurizio; Lockhart, R.; Niedermann, P.; Overstolz, T.; Hoogerwerf, A.; Mayor, J.-M.; Pierer, J.; Bosshard, C.; Ischer, R.; Voirin, G.; Stanley, R. P.

    2017-11-01

    The interest in MEMS based Micro-Spectrometers is increasing due to their potential in terms of flexibility as well as cost, low mass, small volume and power savings. This interest, especially in the Near-Infrared and Mid- Infrared, ranges from planetary exploration missions to astronomy, e.g. the search for extra solar planets, as well as to many other terrestrial fields of application such as, industrial quality and surface control, chemical analysis of soil and water, detection of chemical pollutants, exhausted gas analysis, food quality control, process control in pharmaceuticals, to name a few. A compact MEMS-based Spectrometer for Near- Infrared and Mid-InfraRed operation have been conceived, designed and demonstrated. The design based on tunable MEMS blazed grating, developed in the past at CSEM [1], achieves state of the art results in terms of spectral resolution, operational wavelength range, light throughput, overall dimensions, and power consumption.

  1. Triple axis spectrometers

    Clausen, K.N.

    1997-01-01

    Conventional triple-axis neutron spectroscopy was developed by Brockhouse over thirty years ago' and remains today a versatile and powerful tool for probing the dynamics of condensed matter. The original design of the triple axis spectrometer is technically simple and probes momentum and energy space on a point-by-point basis. This ability to systematically probe the scattering function in a way which only requires a few angles to be moved under computer control and where the observed data in general can be analysed using a pencil and graph paper or a simple fitting routine, has been essential for the success of the method. These constraints were quite reasonable at the time the technique was developed. Advances in computer based data acquisition, neutron beam optics, and position sensitive area detectors have been gradually implemented on many triple axis spectrometer spectrometers, but the full potential of this has not been fully exploited yet. Further improvement in terms of efficiency (beyond point by point inspection) and increased sensitivity (use of focusing optics whenever the problem allows it) could easily be up to a factor of 10-20 over present instruments for many problems at a cost which is negligible compared to that of increasing the flux of the source. The real cost will be in complexity - finding the optimal set-up for a given scan and interpreting the data as the they are taken. On-line transformation of the data for an appropriate display in Q, ω space and analysis tools will be equally important for this task, and the success of these new ideas will crucially depend on how well we solve these problems. (author)

  2. A superconducting electron spectrometer

    Guttormsen, M.; Huebel, H.; Grumbkow, A. von

    1983-03-01

    The set-up and tests of an electron spectrometer for in-beam conversion electron measurements are described. A superconducting solenoid is used to transport the electrons from the target to cooled Si(Li) detectors. The solenoid is designed to produce either a homogeneous axially symmetric field of up to 2 Tesla or a variety of field profiles by powering the inner and outer set of coils of the solenoid separately. The electron trajectories resulting for various field profiles are discussed. In-beam electron spectra taken in coincidence with electrons, gammas and alpha-particles are shown. (Auth.)

  3. Intermediate PT jet spectrometers

    Gutay, L.J.; Koltick, D.; Hauptman, J.; Stork, D.; Theodosiou, G.

    1988-01-01

    A design is presented for a limited solid angle, high resolution double arm spectrometer at 90 degree to the begin, with a vertex detector and particle identification in both arms. The jet arm is designed to accept a complete jet, and identify its substructure of sub-jets, hadrons, and leptons. The particle arm would measure e,π,K,p ratios for P T 0 to the beam for the purpose of tagging Higgs production by boson fusion, 1 gauge boson (WW, ZZ, and WZ) scattering 2 L, and other processes involving the interactions of virtual gauge bosons

  4. HISS spectrometer at LBL

    Greiner, D.

    1980-11-01

    The Heavy Ion Spectrometer System at LBL is designed to be a general purpose experimental work bench able to support a wide variety of experiments. Our philosophy is to provide instruments capable of investigating, with multi-particle sensitivity, a large portion of phase space. We have not chosen a particular region such as mid-rapidity or projectile frame but, instead, have made sure that the magnet and the instrumentation allow these choices as well as many others. The beam can be brought into the magnet at a variable position and the magnet can be rotated

  5. Resonant ultrasound spectrometer

    Migliori, Albert; Visscher, William M.; Fisk, Zachary

    1990-01-01

    An ultrasound resonant spectrometer determines the resonant frequency spectrum of a rectangular parallelepiped sample of a high dissipation material over an expected resonant response frequency range. A sample holder structure grips corners of the sample between piezoelectric drive and receive transducers. Each transducer is mounted on a membrane for only weakly coupling the transducer to the holder structure and operatively contacts a material effective to remove system resonant responses at the transducer from the expected response range. i.e., either a material such as diamond to move the response frequencies above the range or a damping powder to preclude response within the range. A square-law detector amplifier receives the response signal and retransmits the signal on an isolated shield of connecting cabling to remove cabling capacitive effects. The amplifier also provides a substantially frequency independently voltage divider with the receive transducer. The spectrometer is extremely sensitive to enable low amplitude resonance to be detected for use in calculating the elastic constants of the high dissipation sample.

  6. Prototype Neutron Energy Spectrometer

    Mitchell, Stephen; Mukhopadhyay, Sanjoy; Maurer, Richard; Wolff, Ronald

    2010-01-01

    The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production (ship effect), (a, n) reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

  7. Prototype Neutron Energy Spectrometer

    Stephen Mitchell, Sanjoy Mukhopadhyay, Richard Maurer, Ronald Wolff

    2010-06-16

    The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production [ship effect], [a, n] reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

  8. The SPEDE electron spectrometer

    O'Neill, George

    This thesis presents SPEDE (SPectrometer for Electron DEtection) and documents its construction, testing and performance during commissioning at Jyvaskyla, Finland, before deployment at the HIE-ISOLDE facility at CERN coupled with the MINIBALL array to perform in-beam electron-gamma spectroscopy using post-accelerated radioactive ion beams. Commissioning experiments took place in two two-day stints during spring 2015, coupled with several JUROGAMII gamma-detectors. This spectrometer will help aid in fully understanding exotic regions of the nuclear chart such as regions with a high degree of octupole deformation, and in those nuclei exhibiting shape coexistence. For the rst time, electron spectroscopy has been performed at the target position from states populated in accelerated nuclei via Coulomb excitation. The FWHM of SPEDE is approximately 7 keV at 320 keV, and Doppler correction was possible to improve Doppler broadened peaks. The results are intended to give the reader a full understanding of the dete...

  9. Simulation of the SAGE spectrometer

    Cox, D.M.; Herzberg, R.D. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); Konki, J.; Greenlees, P.T.; Pakarinen, J.; Papadakis, P.; Rahkila, P.; Sandzelius, M.; Sorri, J. [University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Hauschild, K. [Universite Paris-Sud, CSNSM-IN2P3-CNRS, Orsay (France)

    2015-06-15

    The SAGE spectrometer combines a Ge-detector array with a Si detector to allow simultaneous detection of γ-rays and electrons. A comprehensive GEANT4 simulation package of the SAGE spectrometer has been developed with the ability to simulate the expected datasets based on user input files. The measured performance of the spectrometer is compared to the results obtained from the simulations. (orig.)

  10. Simulation of the SAGE spectrometer

    Cox, D.M.; Herzberg, R.D.; Konki, J.; Greenlees, P.T.; Pakarinen, J.; Papadakis, P.; Rahkila, P.; Sandzelius, M.; Sorri, J.; Hauschild, K.

    2015-01-01

    The SAGE spectrometer combines a Ge-detector array with a Si detector to allow simultaneous detection of γ-rays and electrons. A comprehensive GEANT4 simulation package of the SAGE spectrometer has been developed with the ability to simulate the expected datasets based on user input files. The measured performance of the spectrometer is compared to the results obtained from the simulations. (orig.)

  11. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    Jordan, I.; Huppert, M.; Wörner, H. J., E-mail: hwoerner@ethz.ch [Laboratory of Physical Chemistry, ETH Zurich, Vladimir-Prelog-Weg 2, 8093 Zurich (Switzerland); Brown, M. A. [Laboratory for Surface Science and Technology, Department of Materials, ETH Zurich, Vladimir-Prelog-Weg 5, 8093 Zurich (Switzerland); Bokhoven, J. A. van [Institute for Chemical and Bioengineering, ETH Zurich, Vladimir-Prelog-Weg 1, 8093 Zurich (Switzerland); Laboratory for Catalysis and Sustainable Chemistry, Paul Scherrer Institute, 5232 Villigen (Switzerland)

    2015-12-15

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup.

  12. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    Jordan, I.; Huppert, M.; Wörner, H. J.; Brown, M. A.; Bokhoven, J. A. van

    2015-01-01

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup

  13. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    Jordan, I.; Huppert, M.; Brown, M. A.; van Bokhoven, J. A.; Wörner, H. J.

    2015-12-01

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup.

  14. LADEE Neutral Mass Spectrometer Data

    National Aeronautics and Space Administration — This bundle contains the data collected by the Neutral Mass Spectrometer (NMS) instrument aboard the Lunar Atmosphere and Dust Environment Explorer (LADEE)...

  15. xGASS: total cold gas scaling relations and molecular-to-atomic gas ratios of galaxies in the local Universe

    Catinella, Barbara; Saintonge, Amélie; Janowiecki, Steven; Cortese, Luca; Davé, Romeel; Lemonias, Jenna J.; Cooper, Andrew P.; Schiminovich, David; Hummels, Cameron B.; Fabello, Silvia; Geréb, Katinka; Kilborn, Virginia; Wang, Jing

    2018-05-01

    We present the extended GALEX Arecibo SDSS Survey (xGASS), a gas fraction-limited census of the atomic hydrogen (H I) gas content of 1179 galaxies selected only by stellar mass (M⋆ = 109-1011.5 M⊙) and redshift (0.01 new Arecibo observations of 208 galaxies, for which we release catalogues and H I spectra. In addition to extending the GASS H I scaling relations by one decade in stellar mass, we quantify total (atomic+molecular) cold gas fractions and molecular-to-atomic gas mass ratios, Rmol, for the subset of 477 galaxies observed with the IRAM 30 m telescope. We find that atomic gas fractions keep increasing with decreasing stellar mass, with no sign of a plateau down to log M⋆/M⊙ = 9. Total gas reservoirs remain H I-dominated across our full stellar mass range, hence total gas fraction scaling relations closely resemble atomic ones, but with a scatter that strongly correlates with Rmol, especially at fixed specific star formation rate. On average, Rmol weakly increases with stellar mass and stellar surface density μ⋆, but individual values vary by almost two orders of magnitude at fixed M⋆ or μ⋆. We show that, for galaxies on the star-forming sequence, variations of Rmol are mostly driven by changes of the H I reservoirs, with a clear dependence on μ⋆. Establishing if galaxy mass or structure plays the most important role in regulating the cold gas content of galaxies requires an accurate separation of bulge and disc components for the study of gas scaling relations.

  16. Absolute analysis of uranium isotopic concentrations with a gas ion source mass spectrometer; Analyses absolues des concentrations isotopiques de l'uranium par spectrometre de masse equipe d'une source a gaz

    Chaussy, L.; Boyer, R. [Commissariat a l' Energie Atomique, Pierrelatte (France)

    1969-07-01

    Mass spectrometer with electronic bombardment ions source for routine uranium isotopic analysis are used like relative measurements apparatus. We show that such mass spectrometers can be used for absolute measurements with a very high sensitivity and precision which are ten times better than theses of thermo-ionic ions source mass spectrometer. We examine the causes of systematic errors and we give experimental data. In particular natural uranium sample used as reference give: U{sub 5} = 0.7202 {+-} 0.0005 atoms per cent; U{sub 4} = 0.00552 {+-} 0.0003 atoms per cent. The use of this method is justified for standards control. (authors) [French] Les spectrometres de masse a source par bombardement electronique pour l'analyse de l'uranium sous forme d'hexafluorure, sont utilises en routine comme des appareils de mesure relative. On montre que l'on peut utiliser de tels appareils pour effectuer des mesures absolues avec une excellente sensibilite et reproductibilite, dix fois superieure a celle des spectrometres a source thermoionique. On examine en detail les causes d'erreurs systematiques et on donne des resultats experimentaux. En particulier, l'analyse d'un echantillon d'uranium naturel donne: U{sub 5} = 0.7202 {+-} 0.0005 atomes pour cent; U{sub 4} = 0.00552 {+-} 0.0003 atomes pour cent. La technique de mesure est utile pour le controle d'etalons isotopiques. (auteurs)

  17. The Omega spectrometer in the West Hall.

    CERN PhotoLab

    1976-01-01

    Inside the hut which sits on top of the superconducting magnet are the TV cameras that observe the particle events occurring in the spark chambers in the magnet gap below. On the background the two beam lines feeding the spectrometer target, for separated hadrons up to 40 GeV, on the right, for 80 GeV electrons, on the left, respectively. The latter strikes a radiator thus sending into Omega tagged photons up to 80 GeV. On the foreground, the two sections of the large gas Cerenkov counter working at atmospheric pressure, used for trigger purpose.

  18. Micro-optical-mechanical system photoacoustic spectrometer

    Kotovsky, Jack; Benett, William J.; Tooker, Angela C.; Alameda, Jennifer B.

    2013-01-01

    All-optical photoacoustic spectrometer sensing systems (PASS system) and methods include all the hardware needed to analyze the presence of a large variety of materials (solid, liquid and gas). Some of the all-optical PASS systems require only two optical-fibers to communicate with the opto-electronic power and readout systems that exist outside of the material environment. Methods for improving the signal-to-noise are provided and enable mirco-scale systems and methods for operating such systems.

  19. BNL multiparticle spectrometer software

    Saulys, A.C.

    1984-01-01

    This paper discusses some solutions to problems common to the design, management and maintenance of a large high energy physics spectrometer software system. The experience of dealing with a large, complex program and the necessity of having the program controlled by various people at different levels of computer experience has led us to design a program control structure of mnemonic and self-explanatory nature. The use of this control language in both on-line and off-line operation of the program will be discussed. The solution of structuring a large program for modularity so that substantial changes to the program can be made easily for a wide variety of high energy physics experiments is discussed. Specialized tools for this type of large program management are also discussed

  20. A Moessbauer effect spectrometer

    Fayek, M.K.; Abbas, Y.M.; Bahgat, A.A.

    1983-01-01

    A Moessbauer effect spectrometer of Harwell type is installed and put in operation. The driving system is of a constant acceleration mode with a velocity range 40mm/sec. and associated to a 1024 multichannel analyser working in a multiscalar time mode. The gamma ray sources are 50 mCi Co 57 in Pd and 20 mCi Snsup(119m) in Ba Sn(O) 3 . Measurements are taken with the source kept at room temperature, while the absorber can be maintained at various temperatures. Gamma ray resonance spectra of different standard samples are obtained. Zero velocity and magnetic field calibration curves are deduced. Examples of some Moessbauer spectra for running investigated materials with a comprehensive general description are also given

  1. The Philippine spectrometer

    Juliano, J.O.

    1965-01-01

    A notable project for international collaboration, in which participants from Indonesia, Korea, Thailand, China and the Philippines are working together, has been launched in the Philippines with Indian assistance under the aegis of the Agency. This is a regional training and research programme using a neutron crystal spectrometer, which has been established since January 1965 at the Philippine Atomic Research Centre in Diliman, Quezon City, Philippines. It is called the IPA Project after the signatories to a five year trilateral agreement, namely, the Government of India,the Republic of the Philippines, and the International Atomic Energy Agency. The programme is administered by a Joint Committee composed of one representative each of the Philippines, India and the Agency. The objective of this cooperative venture is to establish a research centre on neutron diffraction in which scientists and technicians from any Member State of IAEA in South Asia, South-East Asia and Pacific, or Far East regions could come to participate in research and training. Studies in solid state physics, such a s the structure determination of alloys and organic crystals, studies on the orientation of magnetic moments in the lattice of magnetic substances, and other problems based on elastic and inelastic scattering of neutrons are undertaken. There are a number of research reactors in this region where neutron spectrometers can be utilized and the recent establishment of this cooperative international research and training programme has been a timely one for this area of the world. Indeed, a number of other countries have shown a strong growing interest in the development of the project

  2. Some conceptual designs for a LASSY spectrometer magnet

    Green, M.A.

    1995-09-01

    The LASSY spectrometer is a gas filled spectrometer (hydrogen or helium at a pressure of about 1 torr). The design bending power for the primary bending magnet for the spectrometer will have an induction bend radius product of 2.5 tesla-meters. In order to increase the acceptance of the spectrometer, the bending magnet system must be located close to the target where the desired nuclei are created. The spectrometer magnet system must consist of both bending and focusing elements so that the wide acceptance of particles can be brought to a focus at the analysis point that is down stream from the last magnet element. In order improve the spectrometer resolution and to catch the shortest lived nuclei, the length of the magnet system must be as short as possible. The length for the LASSY spectrometer magnet system from the target to the analysis point has been set at 2.5 meters or less. To improve the resolution of the spectrometer, the bending angle for bending magnet system must be increased to close to 180 degrees. In order to achieve a large bending angle and a short magnet system length, the bending induction must be above 3 tesla and the focusing elements must be combined with the bending elements. As a result, a LASSY spectrometer will have bending magnet with a bending angle from 140 to 170 degrees. This magnet win be combined with one or more focusing magnets (a straight dipole in some places and a combined function dipole in other places). The result is a single superconducting bending magnet with one or more quadrupoles incorporated within the large angle bending magnet

  3. Advances in miniature spectrometer and sensor development

    Malinen, Jouko; Rissanen, Anna; Saari, Heikki; Karioja, Pentti; Karppinen, Mikko; Aalto, Timo; Tukkiniemi, Kari

    2014-05-01

    Miniaturization and cost reduction of spectrometer and sensor technologies has great potential to open up new applications areas and business opportunities for analytical technology in hand held, mobile and on-line applications. Advances in microfabrication have resulted in high-performance MEMS and MOEMS devices for spectrometer applications. Many other enabling technologies are useful for miniature analytical solutions, such as silicon photonics, nanoimprint lithography (NIL), system-on-chip, system-on-package techniques for integration of electronics and photonics, 3D printing, powerful embedded computing platforms, networked solutions as well as advances in chemometrics modeling. This paper will summarize recent work on spectrometer and sensor miniaturization at VTT Technical Research Centre of Finland. Fabry-Perot interferometer (FPI) tunable filter technology has been developed in two technical versions: Piezoactuated FPIs have been applied in miniature hyperspectral imaging needs in light weight UAV and nanosatellite applications, chemical imaging as well as medical applications. Microfabricated MOEMS FPIs have been developed as cost-effective sensor platforms for visible, NIR and IR applications. Further examples of sensor miniaturization will be discussed, including system-on-package sensor head for mid-IR gas analyzer, roll-to-roll printed Surface Enhanced Raman Scattering (SERS) technology as well as UV imprinted waveguide sensor for formaldehyde detection.

  4. MEMS based digital transform spectrometers

    Geller, Yariv; Ramani, Mouli

    2005-09-01

    Earlier this year, a new breed of Spectrometers based on Micro-Electro-Mechanical-System (MEMS) engines has been introduced to the commercial market. The use of these engines combined with transform mathematics, produces powerful spectrometers at unprecedented low cost in various spectral regions.

  5. Commissioning of the vacuum system of the KATRIN Main Spectrometer

    Arenz, M.; Dragoun, Otokar; Kovalík, Alojz; Lebeda, Ondřej; Ryšavý, Miloš; Sentkerestiová, Jana; Slezák, Martin; Špalek, Antonín; Vénos, Drahoslav; Zbořil, Miroslav

    2016-01-01

    Roč. 11, APR (2016), P04011 ISSN 1748-0221 R&D Projects: GA ČR(CZ) GAP203/12/1896; GA MŠk LG14004 Institutional support: RVO:61389005 Keywords : gas systems and purification * neutriono detectors * spectrometers Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.220, year: 2016

  6. A quadrupole mass spectrometer system for nuclear safeguards applications

    Evans, P.J.

    1987-12-01

    An on-line enrichment monitor for nuclear safeguards-related surveillance of a pilot-scale gas centrifuge plant is described. This monitor utilises a quadrupole mass spectrometer to measure the isotopic composition of UF 6 in the feed and product gas streams. Details of the design and construction are given, and several difficulties are identified and discussed. Finally, the performance of this system is illustrated with typical results

  7. Oil and gas impacts on forest ecosystems: findings gleaned from the 2012 Goddard Forum at Penn State University

    Patrick J. Drohan; James C. Finley; Paul Roth; Thomas M. Schuler; Susan L. Stout; Margaret C. Brittingham; Nels C. Johnson

    2012-01-01

    Energy production presents numerous challenges to both industry and land managers across the globe. The recent development of unconventional (shale gas) plays around the world [US Energy Information Administration (USEIA), 2011] has brought attention to the potential for rapid change in affected landscapes and associated ecosystem services. While shale-gas development...

  8. Calibration and intercomparison of neutron moderation spectrometers

    Rimpler, A.; Hermanska, J.; Prouza, Z.

    1989-01-01

    Results have been reported of comparative measurements of neutron fields from bare PuBe and Cf sources using multisphere (Bonner) spectrometers. The experiments were carried out by the Institute of Biophysics and Nuclear Medicine at Charles University in Prague and the National Board for Atomic Safety and Radiation Protection in Berlin. Both sides agreed upon uniform measuring conditions and calibration factors thus rendering possible the comparability of the dosimetric parameters which have been determined and verified, respectively, to an accuracy of ± 10%. 20 refs., 10 tabs., 2 figs. (author)

  9. Ultrasensitive Mid-Infrared In Situ Spectrometer for Planetary Atmospheric Analysis, Phase II

    National Aeronautics and Space Administration — The Small Business Innovative Research Phase I proposal seeks to develop a compact, robust in situ spectrometer capable of detecting multiple gas-phase species in...

  10. Respiratory mass spectrometer

    Mostert, J.W. (Pretoria Univ. (South Africa). Dept. of Anesthesiology)

    1983-06-01

    The high degree of technical perfection of the respiratory mass spectrometer has rendered the instrument feasible for routine monitoring of anesthetized patients. It is proposed that the difference between inspired and expired oxygen tension in mm Hg be equated with whole body oxygen consumption in ml/min/M/sup 2/ body-surface area at STPD, by the expedient of multiplying tension-differences by a factor of 2. Years of experience have confirmed the value of promptly recognizing sudden drops in this l/E tension difference below 50 mm Hg indicative of metabolic injury from hypovolemia or respiratory depression. Rises in l/E tension-differences were associated with shivering as well as voluntary muscle activity. Tension differences of less than 25 mm Hg (equated with a whole-body O/sub 2/ consumption of less than 50 ml O/sub 2//min/M/sup 2/) occurred in a patient in the sitting position for posterior fossa exploration without acidosis, hypoxia or hypotension for several hours prior to irreversible cardiac arrest. The value of clinical monitoring by mass spectrometry is especially impressive in open-heart surgery.

  11. The respiratory mass spectrometer

    Mostert, J.W.

    1983-01-01

    The high degree of technical perfection of the respiratory mass spectrometer has rendered the instrument feasible for routine monitoring of anesthetized patients. It is proposed that the difference between inspired and expired oxygen tension in mm Hg be equated with whole body oxygen consumption in ml/min/M 2 body-surface area at STPD, by the expedient of multiplying tension-differences by a factor of 2. Years of experience have confirmed the value of promptly recognizing sudden drops in this l/E tension difference below 50 mm Hg indicative of metabolic injury from hypovolemia or respiratory depression. Rises in l/E tension-differences were associated with shivering as well as voluntary muscle activity. Tension differences of less than 25 mm Hg (equated with a whole-body O 2 consumption of less than 50 ml O 2 /min/M 2 ) occurred in a patient in the sitting position for posterior fossa exploration without acidosis, hypoxia or hypotension for several hours prior to irreversible cardiac arrest. The value of clinical monitoring by mass spectrometry is especially impressive in open-heart surgery

  12. UCN gravitational spectrometer

    Kawabata, Yuji

    1988-01-01

    Concept design is carried out of two types of ultra cold neutron scallering equipment using the fall-focusing principle. One of the systems comprises a vertical gravitational spectrometer and the other includes a horizontal gravitation analyzer. A study is made of their performance and the following results are obtained. Fall-focusing type ultra cold neutron scattering equipment can achieve a high accuracy for measurement of energy and momentum. Compared with conventional neutron scattering systems, this type of equipment can use neutron very efficiently because scattered neutrons within a larger solid angle can be used. The maximum solid angle is nearly 4π and 2π for the vertical and horizontal type, respectively. Another feature is that the size of equipment can be reduced. In the present concept design, the equipment is spherical with a diameter of about 1 m, as compared with NESSIE which is 6.7 m in length and 4.85 m in height with about the same accuracy. Two horizontal analyzers and a vertical spectroscope are proposed. They are suitable for angle-dependent non-elastic scattering in the neutron velocity range of 6∼15 m/s, pure elastic scattering in the range of 4∼7 m/s, or angle-integration non-elastic scattering in the range of 4∼15 m/s. (N.K.)

  13. Software for mass spectrometer control

    Curuia, Marian; Culcer, Mihai; Anghel, Mihai; Iliescu, Mariana; Trancota, Dan; Kaucsar, Martin; Oprea, Cristiana

    2004-01-01

    The paper describes a software application for the MAT 250 mass spectrometer control, which was refurbished. The spectrometer was bring-up-to-date using a hardware structure on its support where the software application for mass spectrometer control was developed . The software application is composed of dedicated modules that perform given operations. The instructions that these modules have to perform are generated by a principal module. This module makes possible the change of information between the modules that compose the software application. The use of a modal structure is useful for adding new functions in the future. The developed application in our institute made possible the transformation of the mass spectrometer MAT 250 into a device endowed with other new generation tools. (authors)

  14. The Lise spectrometer at Ganil

    Saint-Laurent, M.G.

    1986-08-01

    The doubly achromatic spectrometer LISE is available at the french national heavy ion accelerator GANIL. Experimental results, obtained in radioactive beam production and search for new exotic nuclei are briefly reported

  15. Elements of Tiny Plasma Spectrometers

    National Aeronautics and Space Administration — We propose to advance major elements of a miniaturized plasma spectrometer for flight on future missions. This type of instrument has been developed and successfully...

  16. Electron spectrometers with internal conversion

    Suita, J.C.; Lemos Junior, O.F.; Auler, L.T.; Silva, A.G. da

    1981-01-01

    The efforts that the Department of Physics (DEFI) of Institute of Nuclear Engineering (IEN) are being made aiming at adjusting the electron spectrometers with internal conversion to its necessity, are shown. (E.G.) [pt

  17. On-line mass spectrometry measurement of fission gas release from nuclear fuel submitted to thermal transients

    Guigues, E.; Janulyte, A.; Zerega, Y.; Pontillon, Y.

    2013-06-01

    The work presented in this paper has been performed in the framework of a joint research program between Aix-Marseille University and CEA Cadarache. The aim is to develop a mass spectrometer (MS) device for the MERARG facility. MERARG is devoted to the study of fission gas release measurement, from nuclear fuels submitted to annealing tests in high activity laboratory such as LECA-STAR, thanks to gamma spectrometry. The mass spectrometer will then extend the measurement capability from the γ-emitters gases to all the gases involved in the release in order to have a better understanding of the fission gas release dynamics from fuel during thermal transients. Furthermore, the mass spectrometer instrument combines the capabilities and performances of both on-line (for release kinetic) and off-line implementations (for delayed accurate analysis of capacities containing total release gas). The paper deals with two main axes: (1) the modelling of gas sampling inlet device and its performance and (2) the first MS qualification/calibration results. The inlet device samples the gas and also adapts the pressure between MERARG sweeping line at 1.2 bar and mass spectrometer chamber at high vacuum. It is a two-stage device comprising a capillary at inlet, an intermediate vacuum chamber, a molecular leak inlet and a two-stage pumping device. Pressure drops, conductance and throughputs are estimated both for mass spectrometer operation and for exhaust gas recovery. Possible gas segregation is also estimated and device modification is proposed to attain a more accurate calibration. First experimental results obtained from a standard gas bottle show that the quantitative analysis at a few ppm level can be achieved for all isotopes of Kr and Xe, as well as masses 2 and 4 u. (authors)

  18. A field-deployable gamma-ray spectrometer utilizing xenon at high pressure

    Smith, G.C.; Mahler, G.J.; Yu, B.; Salwen, C.; Kane, W.R.; Lemley, J.R.

    1996-01-01

    Prototype gamma-ray spectrometers utilizing xenon gas at high pressure, suitable for applications in the nuclear safeguards, arms control, and nonproliferation communities, have been developed at Brookhaven National Laboratory (BNL). These spectrometers function as ambient-temperature ionization chambers detecting gamma rays with good efficiency in the energy range 50 keV - 2 MeV, with an energy resolution intermediate between semiconductor (Ge) and scintillation (NaI) spectrometers. They are capable of prolonged, low-power operation without a requirement for cryogenic fluids or other cooling mechanisms, and with the addition of small quantities of 3 He gas, can function simultaneously as efficient thermal neutron detectors

  19. Associated Particle Tagging (APT) in Magnetic Spectrometers

    Jordan, David V.; Baciak, James E.; Stave, Sean C.; Chichester, David; Dale, Daniel; Kim, Yujong; Harmon, Frank

    2012-10-16

    Summary In Brief The Associated Particle Tagging (APT) project, a collaboration of Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL) and the Idaho State University (ISU)/Idaho Accelerator Center (IAC), has completed an exploratory study to assess the role of magnetic spectrometers as the linchpin technology in next-generation tagged-neutron and tagged-photon active interrogation (AI). The computational study considered two principle concepts: (1) the application of a solenoidal alpha-particle spectrometer to a next-generation, large-emittance neutron generator for use in the associated particle imaging technique, and (2) the application of tagged photon beams to the detection of fissile material via active interrogation. In both cases, a magnetic spectrometer momentum-analyzes charged particles (in the neutron case, alpha particles accompanying neutron generation in the D-T reaction; in the tagged photon case, post-bremsstrahlung electrons) to define kinematic properties of the relevant neutral interrogation probe particle (i.e. neutron or photon). The main conclusions of the study can be briefly summarized as follows: Neutron generator: • For the solenoidal spectrometer concept, magnetic field strengths of order 1 Tesla or greater are required to keep the transverse size of the spectrometer smaller than 1 meter. The notional magnetic spectrometer design evaluated in this feasibility study uses a 5-T magnetic field and a borehole radius of 18 cm. • The design shows a potential for 4.5 Sr tagged neutron solid angle, a factor of 4.5 larger than achievable with current API neutron-generator designs. • The potential angular resolution for such a tagged neutron beam can be less than 0.5o for modest Si-detector position resolution (3 mm). Further improvement in angular resolution can be made by using Si-detectors with better position resolution. • The report documents several features of a notional generator design incorporating the

  20. The Omega spectrometer

    CERN PhotoLab

    1974-01-01

    The huge superconducting magnet (3 m inside coil diameter, 2 m gap, 18 kGauss) contains a large number of optical spark chambers partly surrounding a hydrogen target which is hit by the beam entering from behind. The half cylindrical aluminium hut houses eight television cameras viewing the spark chambers from the top. The big gas Cerenkov counter in front of the picture (6 m x 4 m x 3 m) which identifies fast forward particles was constructed at Saclay as a contribution of one of the Omega.

  1. The dependence of bar frequency on galaxy mass, colour, and gas content - and angular resolution - in the local universe

    Erwin, Peter

    2018-03-01

    I use distance- and mass-limited subsamples of the Spitzer Survey of Stellar Structure in Galaxies (S4G) to investigate how the presence of bars in spiral galaxies depends on mass, colour, and gas content and whether large, Sloan Digital Sky Survey (SDSS)-based investigations of bar frequencies agree with local data. Bar frequency reaches a maximum of fbar ≈ 0.70 at M⋆ ˜ 109.7M⊙, declining to both lower and higher masses. It is roughly constant over a wide range of colours (g - r ≈ 0.1-0.8) and atomic gas fractions (log (M_{H I}/ M_{\\star }) ≈ -2.5 to 1). Bars are thus as common in blue, gas-rich galaxies are they are in red, gas-poor galaxies. This is in sharp contrast to many SDSS-based studies of z ˜ 0.01-0.1 galaxies, which report fbar increasing strongly to higher masses (from M⋆ ˜ 1010 to 1011M⊙), redder colours, and lower gas fractions. The contradiction can be explained if SDSS-based studies preferentially miss bars in, and underestimate the bar fraction for, lower mass (bluer, gas-rich) galaxies due to poor spatial resolution and the correlation between bar size and stellar mass. Simulations of SDSS-style observations using the S4G galaxies as a parent sample, and assuming that bars below a threshold angular size of twice the point spread function full width at half-maximum cannot be identified, successfully reproduce typical SDSS fbar trends for stellar mass and gas mass ratio. Similar considerations may affect high-redshift studies, especially if bars grow in length over cosmic time; simulations suggest that high-redshift bar fractions may thus be systematically underestimated.

  2. Development of gas-to-liquid (GTL) processes in the PETROBRAS: a joint process with university through the CTPETRO projects (National Brazilian Plan in Science and Technology for Petroleum and Natural Gas ); Desenvolvimento de processos GTL na PETROBRAS: um processo conjunto com a academia via projetos CTPETRO - Plano Nacional de Ciencia e Tecnologia de Petroleo e Gas Natural

    Sousa-Aguiar, Eduardo Falabella; Sugaya, Marcos de Freitas [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas]. E-mail: falabella@cenpes.petrobras.com.br

    2002-07-01

    This paper discusses the importance of the conversion the natural gas into liquid fuels, the GTL (gas-to-liquid) process, for the Brazilian energetic matrix. The different routes of synthesis gas generation (CO + H2) from the methane are presented. The paper comments on the role played by PETROBRAS and her policy of GTL process development, by using a model jointly with various universities. The work also presents the preliminary results of catalysts development and the respective pilot scale supports, aiming a posterior evaluation in a GTL synthesis pilot plant.

  3. Gas chromatography: mass selective detector

    Lapinskas, R.

    1988-01-01

    The mechanism of mass spectrometry technique directed for detecting molecular structures is described, with some considerations about its operational features. This mass spectrometer is used as a gas chromatography detector. (author)

  4. THE COMPLEXITY THAT THE FIRST STARS BROUGHT TO THE UNIVERSE: FRAGILITY OF METAL-ENRICHED GAS IN A RADIATION FIELD

    Aykutalp, A.; Spaans, M.

    2011-01-01

    The initial mass function (IMF) of the first (Population III) stars and Population II (Pop II) stars is poorly known due to a lack of observations of the period between recombination and reionization. In simulations of the formation of the first stars, it has been shown that, due to the limited ability of metal-free primordial gas to cool, the IMF of the first stars is a few orders of magnitude more massive than the current IMF. The transition from a high-mass IMF of the first stars to a lower-mass current IMF is thus important to understand. To study the underlying physics of this transition, we performed several simulations using the cosmological hydrodynamic adaptive mesh refinement code Enzo for metallicities of 10 -4 , 10 -3 , 10 -2 , and 10 -1 Z sun . In our simulations, we include a star formation prescription that is derived from a metallicity-dependent multi-phase interstellar medium (ISM) structure, an external UV radiation field, and a mechanical feedback algorithm. We also implement cosmic ray heating, photoelectric heating, and gas-dust heating/cooling, and follow the metal enrichment of the ISM. It is found that the interplay between metallicity and UV radiation leads to the coexistence of Pop III and Pop II star formation in non-zero-metallicity (Z/Z sun ≥ 10 -2 ) gas. A cold (T 10 -22 g cm -3 ) gas phase is fragile to ambient UV radiation. In a metal-poor (Z/Z sun ≤ 10 -3 ) gas, the cold and dense gas phase does not form in the presence of a radiation field of F 0 ∼ 10 -5 -10 -4 erg cm -2 s -1 . Therefore, metallicity by itself is not a good indicator of the Pop III-Pop II transition. Metal-rich (Z/Z sun ≥ 10 -2 ) gas dynamically evolves two to three orders of magnitude faster than metal-poor gas (Z/Z sun ≤ 10 -3 ). The simulations including supernova explosions show that pre-enrichment of the halo does not affect the mixing of metals.

  5. Universal fine structure of the specific heat at the critical λ-point for an ideal Bose gas in an arbitrary trap

    Tarasov, S V; Kocharovsky, Vl V; Kocharovsky, V V

    2014-01-01

    We analytically find the universal fine structure of the noted discontinuity in the value and/or derivative of the specific heat of an ideal Bose gas in an arbitrary trap in the whole critical region around the λ-point of the Bose–Einstein condensation. The result reveals a remarkable dependence of the λ-point structure on the trap's form and boundary conditions, even for a macroscopically large system. We suggest measuring this strong effect in the experiments with a controllable trap potential. (paper)

  6. Spectrometers for compact neutron sources

    Voigt, J.; Böhm, S.; Dabruck, J. P.; Rücker, U.; Gutberlet, T.; Brückel, T.

    2018-03-01

    We discuss the potential for neutron spectrometers at novel accelerator driven compact neutron sources. Such a High Brilliance Source (HBS) relies on low energy nuclear reactions, which enable cryogenic moderators in very close proximity to the target and neutron optics at comparably short distances from the moderator compared to existing sources. While the first effect aims at increasing the phase space density of a moderator, the second allows the extraction of a large phase space volume, which is typically requested for spectrometer applications. We find that competitive spectrometers can be realized if (a) the neutron production rate can be synchronized with the experiment repetition rate and (b) the emission characteristics of the moderator can be matched to the phase space requirements of the experiment. MCNP simulations for protons or deuterons on a Beryllium target with a suitable target/moderator design yield a source brightness, from which we calculate the sample fluxes by phase space considerations for different types of spectrometers. These match closely the figures of todays spectrometers at medium flux sources. Hence we conclude that compact neutron sources might be a viable option for next generation neutron sources.

  7. Chirped Pulse Spectrometer Operating at 200 GHz

    Hindle, Francis; Bray, Cédric; Hickson, Kevin; Fontanari, Daniele; Mouelhi, Meriem; Cuisset, Arnaud; Mouret, Gaël; Bocquet, Robin

    2018-01-01

    The combination of electronic sources operating at high frequencies and modern microwave instrumentation has enabled the recent development of chirped pulse spectrometers for the millimetre and THz bands. This type of instrument can operate at high resolution which is particularly suited to gas-phase rotational spectroscopy. The construction of a chirped pulse spectrometer operating at 200 GHz is described in detail while attention is paid to the phase stability and the data accumulation over many cycles. Validation using carbonyl sulphide has allowed the detection limit of the instrument to be established as function of the accumulation. A large number of OCS transitions were identified using a 10-GHz chirped pulse and include the six most abundant isotopologues, the weakest line corresponding to the fundamental R(17) transition of 16O13C33S with a line strength of 4.3 × 10-26 cm-1/(molecule cm-2). The linearity of the system response for different degrees of data accumulation and transition line strength was confirmed over four orders of magnitudes. A simple analysis of the time-domain data was demonstrated to provide the line-broadening coefficient without the need for conversion by a Fourier transform. Finally, the pulse duration is discussed and optimal values are given for both Doppler-limited and collisional regimes.

  8. Performance Validation of the ATLAS Muon Spectrometer

    Mair, Katharina

    ATLAS (A Toroidal LHC ApparatuS) is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN, which is scheduled to begin operation in the year 2007, providing experiments with proton-proton collisions. The center-of-mass energy of 14TeV and the design luminosity of 1034 cm−2s−1 will allow to explore many new aspects of fundamental physics. The ATLAS Muon Spectrometer aims at a momentum resolution better than 10% for transverse momentum values ranging from pT = 6 GeV to pT = 1TeV. Precision tracking will be performed by Ar-CO2-gas filled Monitored Drift Tube chambers (MDTs), with a single wire resolution of < 100 μm. In total, about 1 200 chambers, arranged in a large structure, will allow muon track measurements over distances up to 15m in a magnetic field of 0.5 T. Given the large size of the spectrometer it is impossible to keep the shape of the muon chambers and their positions stable within the requested tracking accuracy of 50 μm. Therefore the concept of an optical alig...

  9. New mass spectrometers for hydrogen isotope analyses

    Chastagner, P.; Daves, H.L.; Hess, W.B.

    1981-01-01

    Two advanced mass spectrometers for the accurate analysis of mixtures of the hydrogen isotopes are being evaluated by Du Pont personnel at the Savannah River Laboratory. One is a large double-focusing instrument with a resolution of 2000 at mass 4, an abundance sensitivity of > 100,000 for the HT-D 2 doublet, and a sophisticated electronic control and data collection system. The second is a smaller, simpler, stigmatic-focusing instrument in which exceptionally high ion intensities (> 1 x 10 -9 A) result in high signal to noise ratios. A containment facility with sample inlet systems and a standard distribution system was built to permit testing with tritium mixtures. The characteristics of the mass spectrometers under a variety of operating conditions will be presented. Factors to be discussed include: sample equilibration and its elimination; linearity; trimer formation; gas interference; stability; signal to noise ratio; mass discrimination; and anticipated precision and accu sublimed molybdenum collector of Converter No. 262; and (3) demonstration of tungsten CVD onto molybdenum flange using a reuseable graphite mandrel

  10. Extending The Useful Life Of Older Mass Spectrometers

    Johnson, S.; Cordaro, J.; Holland, M.; Jones, V.

    2010-01-01

    Thermal ionization and gas mass spectrometers are widely used across the Department of Energy (DOE) Complex and contractor laboratories. These instruments support critical missions, where high reliability and low measurement uncertainty are essential. A growing number of these mass spectrometers are significantly older than their original design life. The reality is that manufacturers have declared many of the instrument models obsolete, with direct replacement parts and service no longer available. Some of these obsolete models do not have a next generation, commercially available replacement. Today's budget conscious economy demands for the use of creative funds management. Therefore, the ability to refurbish (or upgrade) these valuable analytical tools and extending their useful life is a cost effective option. The Savannah River Site (SRS) has the proven expertise to breathe new life into older mass spectrometers, at a significant cost savings compared to the purchase and installation of new instruments. A twenty-seven year old Finnigan MAT-261(trademark) Thermal Ionization Mass Spectrometer (TIMS), located at the SRS F/H Area Production Support Laboratory, has been successfully refurbished. Engineers from the Savannah River National Laboratory (SRNL) fabricated and installed the new electronics. These engineers also provide continued instrument maintenance services. With electronic component drawings being DOE Property, other DOE Complex laboratories have the option to extend the life of their aged Mass Spectrometers.

  11. Mini ion trap mass spectrometer

    Dietrich, D.D.; Keville, R.F.

    1995-09-19

    An ion trap is described which operates in the regime between research ion traps which can detect ions with a mass resolution of better than 1:10{sup 9} and commercial mass spectrometers requiring 10{sup 4} ions with resolutions of a few hundred. The power consumption is kept to a minimum by the use of permanent magnets and a novel electron gun design. By Fourier analyzing the ion cyclotron resonance signals induced in the trap electrodes, a complete mass spectra in a single combined structure can be detected. An attribute of the ion trap mass spectrometer is that overall system size is drastically reduced due to combining a unique electron source and mass analyzer/detector in a single device. This enables portable low power mass spectrometers for the detection of environmental pollutants or illicit substances, as well as sensors for on board diagnostics to monitor engine performance or for active feedback in any process involving exhausting waste products. 10 figs.

  12. Evaluation of the ROTAX spectrometer

    Tietze-Jaensch, H.; Schmidt, W.; Geick, R.

    1997-01-01

    After installation of the new-type rotating crystal analyser spectrometer ROTAX at ISIS, we report on practical experience and describe its current status. The rotating analyser technique works feasibly and reliably and provides an ultimate scan flexibility on a pulsed time-of-flight neutron spectrometer. The spinning analyser achieves a mulitplex advantage factor of ca. 50 without compromising the resolution of the instrument. Despite these instrument merits its individual beam position at ISIS has only an unsatisfactorily weak flux, thus hindering this instrument yet to become fully competitive with other high-performance neutron spectrometers based at high-flux reactors. However, we strongly recommend a ROTAX-type instrument to be emphasized when the instrumentation suite of the future European spallation source ESS will come under scrutiny. (orig.)

  13. Forward spectrometers at the SSC

    Bjorken, J.D.

    1986-01-01

    Most of SSC phase space and a great deal of physics potential is in the forward/backward region (absolute value of theta < 100 mrad). Comprehensive open-geometry spectrometers are feasible and very cost effective. Examples of such devices are sketched. Because such spectrometers are very long and may operate at high β and longer bunch spacing, they impact now on SSC interaction - region design. The data acquisition load is as heavy as for central detectors, although there may be less emphasis on speed and more emphasis on sophisticated parallel and/or distributed processing for event selection, as well as on high-capacity buffering

  14. A universal approach to electrically connecting nanowire arrays using nanoparticles—application to a novel gas sensor architecture

    Parthangal, Prahalad M.; Cavicchi, Richard E.; Zachariah, Michael R.

    2006-08-01

    We report on a novel, in situ approach toward connecting and electrically contacting vertically aligned nanowire arrays using conductive nanoparticles. The utility of the approach is demonstrated by development of a gas sensing device employing this nano-architecture. Well-aligned, single-crystalline zinc oxide nanowires were grown through a direct thermal evaporation process at 550 °C on gold catalyst layers. Electrical contact to the top of the nanowire array was established by creating a contiguous nanoparticle film through electrostatic attachment of conductive gold nanoparticles exclusively onto the tips of nanowires. A gas sensing device was constructed using such an arrangement and the nanowire assembly was found to be sensitive to both reducing (methanol) and oxidizing (nitrous oxides) gases. This assembly approach is amenable to any nanowire array for which a top contact electrode is needed.

  15. A universal approach to electrically connecting nanowire arrays using nanoparticles-application to a novel gas sensor architecture

    Parthangal, Prahalad M; Cavicchi, Richard E; Zachariah, Michael R

    2006-01-01

    We report on a novel, in situ approach toward connecting and electrically contacting vertically aligned nanowire arrays using conductive nanoparticles. The utility of the approach is demonstrated by development of a gas sensing device employing this nano-architecture. Well-aligned, single-crystalline zinc oxide nanowires were grown through a direct thermal evaporation process at 550 deg. C on gold catalyst layers. Electrical contact to the top of the nanowire array was established by creating a contiguous nanoparticle film through electrostatic attachment of conductive gold nanoparticles exclusively onto the tips of nanowires. A gas sensing device was constructed using such an arrangement and the nanowire assembly was found to be sensitive to both reducing (methanol) and oxidizing (nitrous oxides) gases. This assembly approach is amenable to any nanowire array for which a top contact electrode is needed

  16. Interfacing an aspiration ion mobility spectrometer to a triple quadrupole mass spectrometer

    Adamov, Alexey; Viidanoja, Jyrki; Kaerpaenoja, Esko; Paakkanen, Heikki; Ketola, Raimo A.; Kostiainen, Risto; Sysoev, Alexey; Kotiaho, Tapio

    2007-01-01

    This article presents the combination of an aspiration-type ion mobility spectrometer with a mass spectrometer. The interface between the aspiration ion mobility spectrometer and the mass spectrometer was designed to allow for quick mounting of the aspiration ion mobility spectrometer onto a Sciex API-300 triple quadrupole mass spectrometer. The developed instrumentation is used for gathering fundamental information on aspiration ion mobility spectrometry. Performance of the instrument is demonstrated using 2,6-di-tert-butyl pyridine and dimethyl methylphosphonate

  17. AI mass spectrometers for space shuttle health monitoring

    Adams, F. W.

    1991-01-01

    The facility Hazardous Gas Detection System (HGDS) at Kennedy Space Center (KSC) is a mass spectrometer based gas analyzer. Two instruments make up the HGDS, which is installed in a prime/backup arrangement, with the option of using both analyzers on the same sample line, or on two different lines simultaneously. It is used for monitoring the Shuttle during fuel loading, countdown, and drainback, if necessary. The use of complex instruments, operated over many shifts, has caused problems in tracking the status of the ground support equipment (GSE) and the vehicle. A requirement for overall system reliability has been a major force in the development of Shuttle GSE, and is the ultimate driver in the choice to pursue artificial intelligence (AI) techniques for Shuttle and Advanced Launch System (ALS) mass spectrometer systems. Shuttle applications of AI are detailed.

  18. Electricity and Water Supply Consumption and Greenhouse Gas Emission at the Office of the Faculty of Science and Technology, Suan Sunandha Rajabhat University

    Ronbanchob Apiratikul

    2015-07-01

    Full Text Available This work was a data collection of electricity and water supply consumption of the Dean’s Office of the Faculty of Science and Technology, Suan Sunandha Rajabhat University, Thailand. The greenhouse gas emissions from electricity and water supply consumptions were calculated using the up-to-date emission factor from the Thailand Greenhouse Gas Management Organization (TGO database. In average, the office consumes 1.045 m3 /d and 87.9 kWh/d of water and electricity, respectively. This is equal to 68.5 Liter per person (11.25 L/m2 and 4.1 kWh per person (0.6788 kWh /m2 for the daily water supply and electricity consumptions, respectively. The total daily greenhouse gas emission from both electricity and water supply consumption is 59.01 kg-CO2 eq. which is mainly came from the electricity consumption (≈ 98%. The average emission based on people and area are 2.566 kg-CO2 eq per person and 0.422 kg-CO2/m2 , respectively.

  19. Small angle single arm spectrometer

    Chien, C.Y.

    1976-01-01

    A study is given of an experiment described in the 1975 Summer Study to review the adequacy of the apparatus for its physics goals, equipment needs, logistic needs, vacuum chambers, compatibility with other experiments and to summarize its impacts on ISABELLE. The spectrometer is designed to study single particle inclusive spectra near x = 1 with particle identification and good momentum resolution

  20. Charged particle scintillation mass spectrometer

    Baranov, P.S.; Zhuravlev, E.E.; Nafikov, A.A.; Osadchi , A.I.; Raevskij, V.G.; Smirnov, P.A.; Cherepnya, S.N.; Yanulis, Yu.P.

    1982-01-01

    A scintillation mass-spectrometer for charged particle identification by the measured values of time-of-flight and energy operating on line with the D-116 computer is described. Original time detectors with 100x100x2 mm 3 and 200x2 mm 2 scintillators located on the 1- or 2 m path length are used in the spectrometer. The 200x200x200 mm 3 scintillation unit is used as a E-counter. Time-of-flight spectra of the detected particles on the 2 m path length obtained in spectrometer test in the beam of charged particles escaping from the carbon target at the angle of 130 deg under 1.2 GeV bremsstrahlung beam of the ''Pakhra'' PIAS synchrotron are presented. Proton and deuteron energy spectra as well as mass spectrum of all the particles detected by the spectrometer are given. Mass resolution obtained on the 2 m path length for π-mesons is +-25%, for protons is +-5%, for deuterons is +-3%

  1. IPNS-I chopper spectrometers

    Price, D.L.; Carpenter, J.M.; Pelizzari, C.A.; Sinha, S.K.; Bresof, I.; Ostrowski, G.E.

    1982-01-01

    We briefly describe the layout and operation of the two chopper experiments at IPNS-I. The recent measurement on solid 4 He by Hilleke et al. provides examples of time-of-flight data from the Low Resolution Chopper Spectrometer

  2. The story of a spectrometer

    Butcher, P.; Uhrberg, R.

    1995-01-01

    This article describes the development and design of a photoelectron spectrometer for use by researchers using synchrotron radiation. Originally developed for a new beam line at the MAXI Synchrotron at Lund in Sweden, the device has many research applications where its high level of performance is required. (UK)

  3. Mid infrared MEMS FTIR spectrometer

    Erfan, Mazen; Sabry, Yasser M.; Mortada, Bassem; Sharaf, Khaled; Khalil, Diaa

    2016-03-01

    In this work we report, for the first time to the best of our knowledge, a bulk-micromachined wideband MEMS-based spectrometer covering both the NIR and the MIR ranges and working from 1200 nm to 4800 nm. The core engine of the spectrometer is a scanning Michelson interferometer micro-fabricated using deep reactive ion etching (DRIE) technology. The spectrum is obtained using the Fourier Transform techniques that allows covering a very wide spectral range limited by the detector responsivity. The moving mirror of the interferometer is driven by a relatively large stroke electrostatic comb-drive actuator. Zirconium fluoride (ZrF4) multimode optical fibers are used to connect light between the white light source and the interferometer input, as well as the interferometer output to a PbSe photoconductive detector. The recorded signal-to-noise ratio is 25 dB at the wavelength of 3350 nm. The spectrometer is successfully used in measuring the absorption spectra of methylene chloride, quartz glass and polystyrene film. The presented solution provides a low cost method for producing miniaturized spectrometers in the near-/mid-infrared.

  4. Inside the ETH spectrometer magnet

    1974-01-01

    The ETH spectrometer magnet being prepared for experiment S134, which uses a frozen spin polarized target to study the associated production of a kaon and a lambda by negative pions interacting with protons (CERN-ETH, Zurich-Helsinki-Imperial College, London-Southampton Collaboration). (See Photo Archive 7406316)

  5. Photoacoustic trace gas sensing : application to fruit and insects

    Persijn, Stefan Timotheüs

    2001-01-01

    A novel photoacoustic spectrometer has been applied to study trace gas emissions by fruit and insects. The spectrometer is based on a newly designed CO laser that can operate on 400 laser lines between 5.1-8.0 and 2.8-4.1 micrometer (delta v=1 and 2 mode, respectively). The spectrometer is equipped

  6. Design of a large superconducting spectrometer magnet

    Shintomi, T.; Makida, Y.; Mito, T.; Yamanoi, Y.; Hashimito, O.; Nagae, T.

    1989-04-01

    The superconducting spectrometer magnet for nuclear physics experiments has been under construction by Institute for Nuclear Study, University of Tokyo with collaboration from KEK. The magnet has a sector type coil. The magnetic field is 3 T with the magnet gap of 50 cm and the stored energy is 11.8 MJ. The easy operation and maintenance are taken into consideration in addition to usual design concept. Three dimensional magnetic field calculation and the stress analysis have been performed. The code 'QUENCH' was applied to decide the operation current and to check the safety of the coil. As a result, the current of 500 A was selected. The heat leaks were checked and estimated less than 2 W at 4 K. A small refrigerator is to be used for thermal insulations at 80 and 20 K. (author)

  7. Influence of the coupling between an atmospheric pressure ion mobility spectrometer and the low pressure ion inlet of a mass spectrometer on the mobility measurement

    Gunzer Frank

    2016-01-01

    Full Text Available Ion mobility spectrometers (IMS are versatile gas analyzers. Due to their small size and robustness, combined with a very high sensitivity, they are often used in gas sensing applications such as environmental monitoring. In order to improve the selectivity, they are typically combined with a mass spectrometer (MS. Since IMS works at atmospheric pressure, and MS works at vacuum, a special interface reducing the pressure over normally two stages has to be used. In this paper the influence of this coupling of different pressure areas on the IMS signal will be analyzed with help of finite elements method simulations.

  8. Compact Spectrometers Based on Linear Variable Filters

    National Aeronautics and Space Administration — Demonstrate a linear-variable spectrometer with an H2RG array. Linear Variable Filter (LVF) spectrometers provide attractive resource benefits – high optical...

  9. Scintillation forward spectrometer of the SPHERE setup

    Anisimov, Yu.S.; Afanas'ev, S.V.; Bondarev, V.K.

    1991-01-01

    The construction of the forward spectrometer for the 4π SPHERE setup to study multiple production of particles in nucleus-nucleus interactions is described. The measured parameters of the spectrometer detectors are presented. 7 refs.; 14 figs.; 1 tab

  10. Combined raman spectrometer/laser-induced breakdown spectrometer design concept

    Bazalgette Courrèges-Lacoste, Gregory; Ahlers, Berit; Boslooper, Erik; Rull-Perez, Fernando; Maurice, Sylvestre

    2017-11-01

    Amongst the different instruments that have been preselected to be on-board the Pasteur payload on ExoMars is the Raman/ Laser Induced Breakdown Spectroscopy (LIBS) instrument. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities. An international team under the lead of TNO has been gathered to produce a design concept for a combined Raman Spectrometer/ LIBS Elegant Bread-Board (EBB). The instrument is based on a specifically designed extremely compact spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. Low mass, size and resources are the main drivers of the instrument's design concept. The proposed design concept, realization and testing programme for the combined Raman/ LIBS EBB is presented as well as background information on Raman and LIBS.

  11. α-rays induced background in ultra low level counting with Ge spectrometers

    Hubert, P.; Dassie, D.; Larrieu, P.; Leccia, F.; Mennrath, P.; Chevallier, J.; Chevallier, A.; Morales, A.; Nunez-Lagoz, R.; Morales, J.; Villar, J.A.

    1986-01-01

    Background spectra of several spectrometers have been recorded in a deep underground laboratory located in the Frejus tunnel. The results show that an α ray induced background from the 210 Pb decay is observed. A possible explanation could be related to the adsorption of the Rn gas on the surfaces of the Ge crystal and/or other parts during the assembly of the spectrometer. (orig.)

  12. Acquisition of HPLC-Mass Spectrometer

    2015-08-18

    31-Jan-2015 Approved for Public Release; Distribution Unlimited Final Report: Acquisition of HPLC -Mass Spectrometer The views, opinions and/or findings...published in peer-reviewed journals: Final Report: Acquisition of HPLC -Mass Spectrometer Report Title The acquisition of the mass spectrometer has been a

  13. Lessons learned with the SAGE spectrometer

    Sorri, J; Greenlees, P T; Jones, P; Julin, R; Konki, J; Pakarinen, J; Rahkila, P; Sandzelius, M; Uusitalo, J; Papadakis, P; Cox, D M; Herzberg, R D

    2012-01-01

    The SAGE spectrometer combines a high-efficiency γ-ray detection system with an electron spectrometer. Some of the design features have been known to be problematic and surprises have come up during the early implementation of the spectrometer. Tests related to bismuth germanate Compton-suppression shields, electron detection efficiency and an improved cooling system are discussed in the paper. (paper)

  14. Airborne gamma ray spectrometer surveying

    1991-01-01

    The International Atomic Energy Agency (IAEA) in its role as collector and disseminator of information on nuclear techniques has long had an interest in gamma ray spectrometer methods and has published a number of Technical Reports on various aspects of the subject. At an Advisory Group Meeting held in Vienna in November 1986 to review appropriate activities the IAEA could take following the Chernobyl accident, it was recommended that preparation begin on a new Technical Report on airborne gamma ray spectrometer surveying, taking into account the use of the technique for environmental monitoring as well as for nuclear emergency response requirements. Shortly thereafter the IAEA became the lead organization in the Radioelement Geochemical Mapping section of the International Geological Correlation Programme/United Nations Educational, Scientific and Cultural Organization (UNESCO) Project on International Geochemical Mapping. These two factors led to the preparation of the present Technical Report. 18 figs, 4 tabs

  15. Development of cold neutron spectrometers

    Lee, Changhee; Lee, C. H.; So, J. Y.; Park, S.; Han, Y. S.; Cho, S. J.; Moon, M. K.; Choi, Y. H.; Sun, G. M.

    2012-03-01

    □ Cold Neutron Triple Axsis Spectrometer (Cold-TAS) Development Ο Fabrication and Installation of the Major Cold-TAS Components Ο Performance Test of the Cold-TAS □ Cold Neutron Time-of-Flight Spectrometer(DC-TOF) Development Ο Fabrication of the Major DC-TOF Components Ο Development DC-TOF Data Reduction Software □ Expected Contribution The two world-class inelastic neutron scattering instruments measure atomic or molecular scale dynamics of meV energy range. This unprecedented measurement capability in the country will enable domestic and international scientists to observe new phenomena in their materials research to obtain world class results. Especially those who work in the fields of magnetic properties of superconductors and multiferroics, molecular dynamics, etc. will get more benefit from these two instruments

  16. Exploiting a Transmission Grating Spectrometer

    Ronald E. Bell

    2004-12-08

    The availability of compact transmission grating spectrometers now allows an attractive and economical alternative to the more familiar Czerny-Turner configuration for many high-temperature plasma applications. Higher throughput is obtained with short focal length refractive optics and stigmatic imaging. Many more spectra can be obtained with a single spectrometer since smaller, more densely packed optical input fibers can be used. Multiple input slits, along with a bandpass filter, can be used to maximize the number of spectra per detector, providing further economy. Curved slits can correct for the strong image curvature of the short focal length optics. Presented here are the governing grating equations for both standard and high-dispersion transmission gratings, defining dispersion, image curvature, and desired slit curvature, that can be used in the design of improved plasma diagnostics.

  17. Exploiting a Transmission Grating Spectrometer

    Bell, Ronald E.

    2004-01-01

    The availability of compact transmission grating spectrometers now allows an attractive and economical alternative to the more familiar Czerny-Turner configuration for many high-temperature plasma applications. Higher throughput is obtained with short focal length refractive optics and stigmatic imaging. Many more spectra can be obtained with a single spectrometer since smaller, more densely packed optical input fibers can be used. Multiple input slits, along with a bandpass filter, can be used to maximize the number of spectra per detector, providing further economy. Curved slits can correct for the strong image curvature of the short focal length optics. Presented here are the governing grating equations for both standard and high-dispersion transmission gratings, defining dispersion, image curvature, and desired slit curvature, that can be used in the design of improved plasma diagnostics

  18. QQDDQ magnet spectrometer 'BIG KARL'

    Martin, S A; Hardt, A; Meissburger, J; Berg, G P.A.; Hacker, U; Huerlimann, W; Roemer, J G.M.; Sagefka, T; Retz, A; Schult, O W.B.

    1983-09-01

    A magnet spectrometer consisting of two quadrupoles, two dipole magnets and another larger quadrupole in front of the detector was designed and installed at the nuclear research institute of the KFA Juelich. It has been used for charged-particle spectroscopy at the isochronous cyclotron since early 1979. Special features of the spectrometer are variable and high dispersion, coils for higher order field corrections in the dipole magnets and a focal plane perpendicular to the optical axis. A large mass-energy product of mE/q/sup 2/ < 540 u x MeV, an angular acceptance of d..cap omega..<12.5 msr, a high resolving power of p/..delta..p up to 3 x 10/sup 4/ and the possibility of kinematical corrections up to K=0.8 make the instrument a very versatile tool for many experiments in the fields of nuclear and atomic physics. 51 references.

  19. Heavy-ion-spectrometer system

    1982-05-01

    LBL safety policy (Pub 300 Appendix E) states that every research operation with a Class A risk potential (DOE 5484.1) should identify potentially hazardous procedures associated with the operation and develop methods for accomplishing the operation safely without personnel injury or property damage. The rules and practices that management deems to be minimally necessary for the safe operations of the Heavy Ion Spectrometer System (HISS) in the Bevatron Experimental Hall (51B) are set forth in this Operation Safety Procedures

  20. The HISS spectrometer at LBL

    Greiner, D.

    1981-01-01

    The Heavy Ion Spectrometer System at LBL is designed to be a general purpose experimental work bench able to support a wide variety of experiments. Our philosophy is to provide instruments capable of investigating, with multi-particle sensitivity, a large portion of phase space. We have not chosen a particular region such as mid-rapidity or projectile frame, but instead, have made sure that the magnet and the instrumentation allow these choices as well as many others. (orig.)

  1. Heavy-ion-spectrometer system

    1982-05-01

    LBL safety policy (Pub 300 Appendix E) states that every research operation with a Class A risk potential (DOE 5484.1) should identify potentially hazardous procedures associated with the operation and develop methods for accomplishing the operation safely without personnel injury or property damage. The rules and practices that management deems to be minimally necessary for the safe operations of the Heavy Ion Spectrometer System (HISS) in the Bevatron Experimental Hall (51B) are set forth in this Operation Safety Procedures (OSP).

  2. A spectrometer for submicron particles

    Pourprix, M.

    1995-01-01

    The electrostatic spectrometer for aerosol particles, is composed of two coaxial parallel conductive disks between which an electric field is established; an annular slot in the first disk allows for the atmosphere air intake. Suction and injection systems, and a third intermediate conductive disk are used to carry out a dynamic confinement that allows for the separation of particles having various electronic mobility and the determination of the suspended particle size distribution. Application to aerosol size spectrum determination and air quality monitoring

  3. The fast slow TDPAC spectrometer

    Cekic, B.; Koicki, S.; Manasijevic, M.; Ivanovic, N.; Koteski, V.; Milosevic, Z.; Radisavljevic, I.; Cavor, J.; Novakovic, N.; Marjanovic, D.

    2001-01-01

    A 2-BaF 2 detector - fast slow time spectrometer for time differential perturbed angular correlations (TDPAC) experiments is described. This apparatus has been developed in the Group for Hyperfine Interactions in the Institute for Nuclear Sciences in VINCA. The excellent time resolution combined with high efficiency offered by these detectors enables one high counting rate performance and is operating in the wide temperature range 78-1200 K. (author)

  4. Medium energy charged particle spectrometer

    Keppler, E.; Wilken, B.; Richer, K.; Umlauft, G.; Fischer, K.; Winterhoff, H.P.

    1976-10-01

    The charged particle spectrometer E8 on HELIOS A and B will be described in some detail. It covers proton energies from 80 keV to 6 MeV, electrons from 20 keV to 2 MeV, and positrons from 150 to 550 keV. Its flight performance will be discussed. From examples of measurements the capability of the instrument will be demonstrated. (orig.) [de

  5. The RISC-spectrometer experiment

    Pinter, Gy.

    1981-01-01

    The RISC (Relativistic Ionising Streamer Chamber) spectrometer (situated at Protvino, joining the accelerator) is discussed, and the experiment carried out in international cooperation is presented. The beam monitor, the trigger system and the control and data recording system as well as the streamer spark chamber are detailed (the latter is the largest of our time). Examples of the main experiments as well as the work carried out in Budapest are discussed briefly. (Sz.J.)

  6. Residual gas analysis

    Berecz, I.

    1982-01-01

    Determination of the residual gas composition in vacuum systems by a special mass spectrometric method was presented. The quadrupole mass spectrometer (QMS) and its application in thin film technology was discussed. Results, partial pressure versus time curves as well as the line spectra of the residual gases in case of the vaporization of a Ti-Pd-Au alloy were demonstrated together with the possible construction schemes of QMS residual gas analysers. (Sz.J.)

  7. Compact imaging Bragg spectrometer for fusion devices

    Bertschinger, G.; Biel, W.; Jaegers, H.; Marchuk, O.

    2004-01-01

    A compact imaging x-ray spectrometer has been designed for tokamaks and stellarators to measure the plasma parameters at different spatial chords. It has been optimized for high spectral resolution and high sensitivity. High spectral resolution is obtained by using solid state detectors and minimizing the imaging errors of the spherical crystals. It is shown, that using spherical crystals the solid angle and hence the throughput can be increased significantly, without compromising the spectral resolution. The design is useful for the measurement of the spectra of He- and H-like ions from Si to Kr. The spectral resolution is sufficient for the measurement of plasma parameters. The temporal resolution is high enough for transport studies by gas puff and laser ablation experiments. The design is based on a modified Johann spectrometer mount, utilizing a spherically bent crystal instead of the cylindrically bent crystal in the traditional Johann mount. The astigmatism of the wavelength selective reflection on the spherical crystal is applied to obtain imaging of an extended plasma source on a two-dimensional detector. For each element, a separate crystal is required, only in few cases, a crystal can be used for the spectra of two elements. For the spectra of most of the He-like ions from Si up to Kr, suitable crystal cuts have been found on quartz, silicon and germanium crystals with Bragg angles in a small interval around the design value of 53.5 deg. All of the crystals have the same radius. They are fixed on a rotational table. The distance to the detector is adjusted by an x-y table to fit to the Rowland circle

  8. Research of aerial imaging spectrometer data acquisition technology based on USB 3.0

    Huang, Junze; Wang, Yueming; He, Daogang; Yu, Yanan

    2016-11-01

    With the emergence of UAV (unmanned aerial vehicle) platform for aerial imaging spectrometer, research of aerial imaging spectrometer DAS(data acquisition system) faces new challenges. Due to the limitation of platform and other factors, the aerial imaging spectrometer DAS requires small-light, low-cost and universal. Traditional aerial imaging spectrometer DAS system is expensive, bulky, non-universal and unsupported plug-and-play based on PCIe. So that has been unable to meet promotion and application of the aerial imaging spectrometer. In order to solve these problems, the new data acquisition scheme bases on USB3.0 interface.USB3.0 can provide guarantee of small-light, low-cost and universal relying on the forward-looking technology advantage. USB3.0 transmission theory is up to 5Gbps.And the GPIF programming interface achieves 3.2Gbps of the effective theoretical data bandwidth.USB3.0 can fully meet the needs of the aerial imaging spectrometer data transmission rate. The scheme uses the slave FIFO asynchronous data transmission mode between FPGA and USB3014 interface chip. Firstly system collects spectral data from TLK2711 of high-speed serial interface chip. Then FPGA receives data in DDR2 cache after ping-pong data processing. Finally USB3014 interface chip transmits data via automatic-dma approach and uploads to PC by USB3.0 cable. During the manufacture of aerial imaging spectrometer, the DAS can achieve image acquisition, transmission, storage and display. All functions can provide the necessary test detection for aerial imaging spectrometer. The test shows that system performs stable and no data lose. Average transmission speed and storage speed of writing SSD can stabilize at 1.28Gbps. Consequently ,this data acquisition system can meet application requirements for aerial imaging spectrometer.

  9. Ion mobility spectrometer / mass spectrometer (IMS-MS).

    Hunka Deborah Elaine; Austin, Daniel E.

    2005-07-01

    The use of Ion Mobility Spectrometry (IMS) in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400). Combining Ion Mobility Spectrometry (IMS) with Mass Spectrometry (MS) is described. The IMS-MS combination overcomes several limitations present in simple IMS systems. Ion mobility alone is insufficient to identify an unknown chemical agent. Collision cross section, upon which mobility is based, is not sufficiently unique or predictable a priori to be able to make a confident peak assignment unless the compounds present are already identified. Molecular mass, on the other hand, is much more readily interpreted and related to compounds. For a given compound, the molecular mass can be determined using a pocket calculator (or in one's head) while a reasonable value of the cross-section might require hours of computation time. Thus a mass spectrum provides chemical specificity and identity not accessible in the mobility spectrum alone. In addition, several advanced mass spectrometric methods, such as tandem MS, have been extensively developed for the purpose of molecular identification. With an appropriate mass spectrometer connected to an ion mobility spectrometer, these advanced identification methods become available, providing greater characterization capability.

  10. Ion Mobility Spectrometer / Mass Spectrometer (IMS-MS)

    Hunka, Deborah E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Austin, Daniel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2005-10-01

    The use of Ion Mobility Spectrometry (IMS)in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400).

  11. Performance of the ATLAS muon spectrometer

    Aleksa, M.

    1999-09-01

    ATLAS is a general-purpose experiment for the future large hadron collider (LHC) at CERN. Its Muon Spectrometer will require ∼5500 m 2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5 m to 15 m length, embedded in a magnetic field of ∼0.5 T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼1200 drift chambers. The LHC physics discovery range indicates the need for a momentum resolution of ∼10 % for muons with a transverse momentum of p T =1 TeV/c. Following a detailed engineering optimisation of the magnetic-field strength versus the chamber resolution, the ATLAS collaboration opted for a drift-chamber system with very high spatial resolution, σ 2 93/7). Measurements performed in a high-background environment - similar to the ATLAS operational environment - gave us a complete understanding of the individual effects which deteriorate the spatial resolution at high rates. Four effects responsible for a resolution deterioration have been identified: two electronics effects which depend on the count rate of a tube (baseline shift and baseline fluctuations), and two space-charge effects that depend on the local count rate (gain drop and field fluctuations). The understanding of these effects had a major impact on the choice of the drift gas and the front-end electronics. The strong dependence of the drift velocity on the drift field is one major disadvantage of the baseline gas. In this work the full set of effects which lead to systematic errors to the track-position measurement in one tube (e.g. variations of the background rate) was investigated and quantified for realistic LHC operating conditions. For the biggest effects analytical corrections are presented. Finally, the muon-system performance was investigated and a calibration method for the absolute mass scale developed. By means of simulation it was shown that the energy

  12. The influence of aerosol density upon the performance of centrifugal spectrometers

    Martonen, T.B.

    1978-01-01

    Centrifugal instruments are valuable components for studying airborne particulate matter of health physics interest because a continuously graded aerodynamic diameter, Dae, spectrum is produced. Applications include the characterization of inhalation exposure aerosols, serving as particle monitors to measure respirable dose, and being the integral unit in a system to generate monodisperse aerosols. Some aerosols of health physics concern differ from the PSL aerosol used to calibrate centrifuges in two main respects: the particulate mass concentration, Cm, is large, and the aerosol gas is not air. The marked influence of these factors upon centrifuge performance is documented (T. B. Martonen, Ph.D. Thesis, University of Rochester, Rochester, NY, 1976). The phenomenon of cloud settling occurs when Cm is of sufficient magnitude. Aerosol gas effects can be defined in terms of the parameter K, the ratio of the aerosol gas to winnowing medium densities. Size classification is modified by diffusiophoretic forces when K 1. In all cases, erroneous size distribution data results. Laboratory procedures are presented which permit accurate particle size assessment when aerosols of large Cm and/or K≠1 are sampled. An engineering analysis of centrifuge physics has been completed which allows optimum operating conditions, which may be quite different for different aerosols, to be computed. Cigarette smoke was used as a test aerosol to check the experimental and theoretical findings. Although it is shown to be subject to both cloud settling and dense gas subsidence, accurate size classification was obtained. The differential equation describing particle motion in centrifuges has been formulated and solved. Further, techniques of dimensional analysis were applied to the equations modelling flow in centrifuges; results indicate how operating conditions and instrument geometry influence particle size classification. These theoretical studies will lead to the development of improved

  13. Rapid monitoring of gaseous radionuclides using a portable spectrometer

    Chung, C.; Tsai, C.H.

    1995-01-01

    A field gamma ray spectrometer, consisting of a portable high purity germanium detector, portable multichannel analyser, and a notebook computer, was used to conduct in situ rapid scanning of radioactive Ar, Kr and Xe isotopes in the air around a nuclear facility. The portable gamma ray spectrometer was calibrated using Ar, Kr, and Xe radioisotopes, activated in a research reactor and released in a sealed chamber. The unit was further tested inside the reactor containment to monitor the concentration of 41 Ar. In a typical one hour field measurement, the detection limits for some rare gas radionuclides corresponded to dose rates around 0.1 nSv.h -1 , which is far less than the dose rate induced by derived air concentrations imposed by the authority. The dose rate due to ground level concentrations of gaseous radionuclides dispersed from a source, such a nuclear facility or nuclear test, can be monitored in a short period using the portable unit. (Author)

  14. New spectrometer for charged particles

    Wajsfelner, Rene

    1970-02-01

    This thesis is devoted to the study and development of an electrostatic spectrometer which is not only more accurate for the determination of size distributions of electrically charged radio-active atmospheric aerosols, but which can also be used for measuring the grain-size distribution of any cloud of particles which will previously have been charged according to a known, reproducible law. An experimental study has been made of the development of this precipitator and also of its calibration. The electrical charge on spherical polystyrene latex particles suspended in air by atomization has been studied; a theoretical explanation of these results is put forward. (author) [fr

  15. Ion Mobility Spectrometer Field Test

    Smith, Nicholas [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; McLain, Derek [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Steeb, Jennifer [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2017-12-20

    The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levels of the radioanalytical instrumentation and determined to be radiologically clean.

  16. The Alpha Magnetic Spectrometer (AMS)

    Alcaraz, J.; Alpat, B.; Ambrosi, G.; Anderhub, H.; Ao, L.; Arefiev, A.; Azzarello, P.; Babucci, E.; Baldini, L.; Basile, M.; Barancourt, D.; Barao, F.; Barbier, G.; Barreira, G.; Battiston, R.; Becker, R.; Becker, U.; Bellagamba, L.; Bene, P.; Berdugo, J.; Berges, P.; Bertucci, B.; Biland, A.; Bizzaglia, S.; Blasko, S.; Boella, G.; Boschini, M.; Bourquin, M.; Brocco, L.; Bruni, G.; Buenerd, M.; Burger, J.D.; Burger, W.J.; Cai, X.D.; Camps, C.; Cannarsa, P.; Capell, M.; Casadei, D.; Casaus, J.; Castellini, G.; Cecchi, C.; Chang, Y.H.; Chen, H.F.; Chen, H.S.; Chen, Z.G.; Chernoplekov, N.A.; Chiueh, T.H.; Chuang, Y.L.; Cindolo, F.; Commichau, V.; Contin, A.; Crespo, P.; Cristinziani, M.; Cunha, J.P. da; Dai, T.S.; Deus, J.D.; Dinu, N.; Djambazov, L.; DAntone, I.; Dong, Z.R.; Emonet, P.; Engelberg, J.; Eppling, F.J.; Eronen, T.; Esposito, G.; Extermann, P.; Favier, J.; Fiandrini, E.; Fisher, P.H.; Fluegge, G.; Fouque, N.; Galaktionov, Yu.; Gervasi, M.; Giusti, P.; Grandi, D.; Grimm, O.; Gu, W.Q.; Hangarter, K.; Hasan, A.; Hermel, V.; Hofer, H.; Huang, M.A.; Hungerford, W.; Ionica, M.; Ionica, R.; Jongmanns, M.; Karlamaa, K.; Karpinski, W.; Kenney, G.; Kenny, J.; Kim, W.; Klimentov, A.; Kossakowski, R.; Koutsenko, V.; Kraeber, M.; Laborie, G.; Laitinen, T.; Lamanna, G.; Laurenti, G.; Lebedev, A.; Lee, S.C.; Levi, G.; Levtchenko, P.; Liu, C.L.; Liu, H.T.; Lopes, I.; Lu, G.; Lu, Y.S.; Luebelsmeyer, K.; Luckey, D.; Lustermann, W.; Mana, C.; Margotti, A.; Mayet, F.; McNeil, R.R.; Meillon, B.; Menichelli, M.; Mihul, A.; Mourao, A.; Mujunen, A.; Palmonari, F.; Papi, A.; Park, I.H.; Pauluzzi, M.; Pauss, F.; Perrin, E.; Pesci, A.; Pevsner, A.; Pimenta, M.; Plyaskin, V.; Pojidaev, V.; Postolache, V.; Produit, N.; Rancoita, P.G.; Rapin, D.; Raupach, F.; Ren, D.; Ren, Z.; Ribordy, M.; Richeux, J.P.; Riihonen, E.; Ritakari, J.; Roeser, U.; Roissin, C.; Sagdeev, R.; Sartorelli, G.; Schultz von Dratzig, A.; Schwering, G.; Scolieri, G.; Seo, E.S.; Shoutko, V.; Shoumilov, E.; Siedling, R.; Son, D.; Song, T.; Steuer, M.; Sun, G.S.; Suter, H.; Tang, X.W.; Ting, S.C.C.Samuel C.C.; Ting, S.M.; Tornikoski, M.; Torsti, J.; Tr umper, J.; Ulbricht, J.; Urpo, S.; Usoskin, I.; Valtonen, E.; Vandenhirtz, J.; Velcea, F.; Velikhov, E.; Verlaat, B.; Vetlitsky, I.; Vezzu, F.; Vialle, J.P.; Viertel, G.; Vite, D.; Gunten, H. Von; Wicki, S.W.S. Waldmeier; Wallraff, W.; Wang, B.C.; Wang, J.Z.; Wang, Y.H.; Wiik, K.; Williams, C.; Wu, S.X.; Xia, P.C.; Yan, J.L.; Yan, L.G.; Yang, C.G.; Yang, M.; Ye, S.W.; Yeh, P.; Xu, Z.Z.; Zhang, H.Y.; Zhang, Z.P.; Zhao, D.X.; Zhu, G.Y.; Zhu, W.Z.; Zhuang, H.L.; Zichichi, A.; Zimmermann, B.

    2002-01-01

    The Alpha Magnetic Spectrometer (AMS) is a large acceptance (0.65 sr m 2 ) detector designed to operate in the International Space Station (ISS) for three years. The purposes of the experiment are to search for cosmic antimatter and dark matter and to study the composition and energy spectrum of the primary cosmic rays. A 'scaled-down' version has been flown on the Space Shuttle Discovery for 10 days in June 1998. The complete AMS is programmed for installation on the ISS in October 2003 for an operational period of 3 yr. This contribution reports on the experimental configuration that will be installed on the ISS

  17. Gas microstrip chambers

    McIntyre, P.M.; Barasch, E.F.; Bowcock, T.J.V.; Demroff, H.P.; Elliott, S.M.; Howe, M.R.; Lee, B.; Mazumdar, T.K.; Pang, Y.; Smith, D.D.; Wahl, J.; Wu, Y.; Yue, W.K.; Gaedke, R.M.; Vanstraelen, G.

    1992-01-01

    The gas microstrip chamber has been developed from concept to experimental system during the past three years. A pattern of anode and grid lines are microfabricated onto a dielectric substrate and configured as a high-resolution MWPC. Four recent developments are described: Suitable plastic substrates and lithography techniques for large-area chambers; non-planar silicon-based chambers for 20 μm resolution; integrated on-board synchronous front-end electronics and data buffering; and a porous silicon active cathode for enhanced efficiency and time response. The microstrip chamber appears to be a promising technology for applications in microvertex, tracking spectrometer, muon spectrometer, and transition radiation detection. (orig.)

  18. ISOLDE Off-line Gas Leak Upgrade

    Nielsen, Kristoffer Bested

    2017-01-01

    This study investigates gas injection system of the ISOLDE Off-line separator. A quadrupole mass spectrometer is used to analysis the composition of the gas. Based on these measurements a contamination of the injected gas is found and a system upgrade is purposed. Furthermore a calibration of the leak rate of the leak valve is made.

  19. Precise determination of cosmogenic Ne in CREU-1 quartz standard, using the Helix-MC Plus mass spectrometer

    Hamilton, D.; Honda, M.; Zhang, X.; Phillips, D.; Matchan, E.

    2017-12-01

    The Helix-MC Plus multi-collector noble gas mass spectrometer at the Australian National University is uniquely equipped with three high mass resolution collectors on H2, Axial and L2 positions. Their mass resolution and mass resolving power are as high as 1,800 and 8,000, respectively. The Helix-MC Plus can totally separate 20Ne+ from 40Ar++ isobaric interference and also partially separate 21Ne+ from 20NeH+ and 22Ne+ from 12C16O2++. By adjusting collector positions, we are able to measure interference-free Ne isotope intensities and have re-determined the 21Ne abundance in air [1]. Analyses by Honda et al. [1] demonstrated that 20Ne1H contributes approximately 2% to previously determined atmospheric 21Ne values [2], and a new atmospheric 21Ne/20Ne ratio of 0.002906 was calculated. Using the Helix-MC Plus mass spectrometer, we measured Ne abundances in the CREU-1 quartz standard [3] and determined cosmogenic concentrations by subtraction of atmospheric Ne with the new atmospheric 21Ne/20Ne value. The average concentration of cosmogenic 21Ne determined from four repeated analyses is 338 ± 12 × 106 atom/g (2σ). This compares with the average concentration of 348 ± 10 × 106 atom/g (2σ) from 45 analyses determined by several laboratories [3], where Ne isotope analyses were undertaken by conventional low resolution mass spectrometers and atmospheric Ne was subtracted using the conventional atmospheric 21Ne/20Ne [2]. On this basis, for a sample with abundant cosmogenic Ne, like CREU-1 quartz, previously measured by low mass resolution mass spectrometers are likely valid and their geological implications are unaffected. However, for low 21Ne concentration samples, combining new generation of mass spectrometers as well as the new atmospheric ratio may have significance for cosmogenic 21Ne surface exposure dating. References: [1] Honda M., et. al., International Journal of Mass Spectrometry, 387, 1 (2015). [2] Eberhardt P., et. al., Zeitschrift fur Naturforschung, 20

  20. A low-volume cavity ring-down spectrometer for sample-limited applications

    Stowasser, C.; Farinas, A. D.; Ware, J.; Wistisen, D. W.; Rella, C.; Wahl, E.; Crosson, E.; Blunier, T.

    2014-08-01

    In atmospheric and environmental sciences, optical spectrometers are used for the measurements of greenhouse gas mole fractions and the isotopic composition of water vapor or greenhouse gases. The large sample cell volumes (tens of milliliters to several liters) in commercially available spectrometers constrain the usefulness of such instruments for applications that are limited in sample size and/or need to track fast variations in the sample stream. In an effort to make spectrometers more suitable for sample-limited applications, we developed a low-volume analyzer capable of measuring mole fractions of methane and carbon monoxide based on a commercial cavity ring-down spectrometer. The instrument has a small sample cell (9.6 ml) and can selectively be operated at a sample cell pressure of 140, 45, or 20 Torr (effective internal volume of 1.8, 0.57, and 0.25 ml). We present the new sample cell design and the flow path configuration, which are optimized for small sample sizes. To quantify the spectrometer's usefulness for sample-limited applications, we determine the renewal rate of sample molecules within the low-volume spectrometer. Furthermore, we show that the performance of the low-volume spectrometer matches the performance of the standard commercial analyzers by investigating linearity, precision, and instrumental drift.

  1. The high-acceptance dielectron spectrometer HADES

    Agakichiev, G.; Destefanis, M.; Gilardi, C.; Kirschner, D.; Kuehn, W.; Lange, J.S.; Lehnert, J.; Lichtblau, C.; Lins, E.; Metag, V.; Mishra, D.; Novotny, R.; Pechenov, V.; Pechenova, O.; Perez Cavalcanti, T.; Petri, M.; Ritman, J.; Salz, C.; Schaefer, D.; Skoda, M.; Spataro, S.; Spruck, B.; Toia, A.; Agodi, C.; Coniglione, R.; Cosentino, L.; Finocchiaro, P.; Maiolino, C.; Piattelli, P.; Sapienza, P.; Vassiliev, D.; Alvarez-Pol, H.; Belver, D.; Cabanelas, P.; Castro, E.; Duran, I.; Fernandez, C.; Fuentes, B.; Garzon, J.A.; Kurtukian-Nieto, T.; Rodriguez-Prieto, G.; Sabin-Fernandez, J.; Sanchez, M.; Vazquez, A.; Atkin, E.; Volkov, Y.; Badura, E.; Bertini, D.; Bielcik, J.; Bokemeyer, H.; Dahlinger, M.; Daues, H.W.; Galatyuk, T.; Garabatos, C.; Gonzalez-Diaz, D.; Hehner, J.; Heinz, T.; Hoffmann, J.; Holzmann, R.; Koenig, I.; Koenig, W.; Kolb, B.W.; Kopf, U.; Lang, S.; Leinberger, U.; Magestro, D.; Muench, M.; Niebur, W.; Ott, W.; Pietraszko, J.; Rustamov, A.; Schicker, R.M.; Schoen, H.; Schoen, W.; Schroeder, C.; Schwab, E.; Senger, P.; Simon, R.S.; Stelzer, H.; Traxler, M.; Yurevich, S.; Zovinec, D.; Zumbruch, P.; Balanda, A.; Kozuch, A.; Przygoda, W.; Bassi, A.; Bassini, R.; Boiano, C.; Bartolotti, A.; Brambilla, S.; Bellia, G.; Migneco, E.; Belyaev, A.V.; Chepurnov, V.; Chernenko, S.; Fateev, O.V.; Ierusalimov, A.P.; Smykov, L.; Troyan, A.Yu.; Zanevsky, Y.V.; Benovic, M.; Hlavac, S.; Turzo, I.; Boehmer, M.; Christ, T.; Eberl, T.; Fabbietti, L.; Friese, J.; Gernhaeuser, R.; Gilg, H.; Homolka, J.; Jurkovic, M.; Kastenmueller, A.; Kienle, P.; Koerner, H.J.; Kruecken, R.; Maier, L.; Maier-Komor, P.; Sailer, B.; Schroeder, S.; Ulrich, A.; Wallner, C.; Weber, M.; Wieser, J.; Winkler, S.; Zeitelhack, K.; Boyard, J.L.; Genolini, B.; Hennino, T.; Jourdain, J.C.; Moriniere, E.; Pouthas, J.; Ramstein, B.; Rosier, P.; Roy-Stephan, M.; Sudol, M.; Braun-Munzinger, P.; Diaz, J.; Dohrmann, F.; Dressler, R.; Enghardt, W.; Heidel, K.; Hutsch, J.; Kanaki, K.; Kotte, R.; Naumann, L.; Sobiella, M.; Wuestenfeld, J.; Zhou, P.; Dybczak, A.; Jaskula, M.; Kajetanowicz, M.; Kidon, L.; Korcyl, K.; Kulessa, R.; Malarz, A.; Michalska, B.; Otwinowski, J.; Ploskon, M.; Prokopowicz, W.; Salabura, P.; Szczybura, M.; Trebacz, R.; Walus, W.; Wisniowski, M.; Wojcik, T.; Froehlich, I.; Lippmann, C.; Lorenz, M.; Markert, J.; Michel, J.; Muentz, C.; Pachmayer, Y.C.; Rosenkranz, K.; Stroebele, H.; Sturm, C.; Tarantola, A.; Teilab, K.; Wang, Y.; Zentek, A.; Golubeva, M.; Guber, F.; Ivashkin, A.; Karavicheva, T.; Kurepin, A.; Lapidus, K.; Reshetin, A.; Sadovsky, A.; Shileev, K.; Tiflov, V.; Grosse, E.; Kaempfer, B.; Iori, I.; Krizek, F.; Kugler, A.; Marek, T.; Novotny, J.; Pleskac, R.; Pospisil, V.; Sobolev, Yu.G.; Suk, M.; Taranenko, A.; Tikhonov, A.; Tlusty, P.; Wagner, V.; Mousa, J.; Parpottas, Y.; Tsertos, H.; Nekhaev, A.; Smolyankin, V.; Palka, M.; Roche, G.; Schmah, A.; Stroth, J.

    2009-01-01

    HADES is a versatile magnetic spectrometer aimed at studying dielectron production in pion, proton and heavy-ion-induced collisions. Its main features include a ring imaging gas Cherenkov detector for electron-hadron discrimination, a tracking system consisting of a set of 6 superconducting coils producing a toroidal field and drift chambers and a multiplicity and electron trigger array for additional electron-hadron discrimination and event characterization. A two-stage trigger system enhances events containing electrons. The physics program is focused on the investigation of hadron properties in nuclei and in the hot and dense hadronic matter. The detector system is characterized by an 85% azimuthal coverage over a polar angle interval from 18 to 85 , a single electron efficiency of 50% and a vector meson mass resolution of 2.5%. Identification of pions, kaons and protons is achieved combining time-of-flight and energy loss measurements over a large momentum range (0.1< p< 1.0 GeV/c). This paper describes the main features and the performance of the detector system. (orig.)

  2. Crystal-diffraction spectrometer of increased efficiency

    Saukov, A.I.; Gornitsyn, G.A.; Morozov, N.A.

    1985-01-01

    The geometry of the spectrometer is illustrated in this paper. An attempt is made to achieve optimal design of the spectrometer by finding the coefficient of reflection of the gamma radiation from the various Ge planes. In these experiments, the Du Mond design was used in the spectrometer. Illustrations are provided to explain dependence of the relative efficiency upon the energy of the gamma quanta

  3. Intracavity Laser Photoacoustic Spectrometer with High Sensitivity

    Mitrayana; Muslim; Wasono, M.A.J.

    2002-01-01

    A photo acoustic spectrometer set-up has been upgraded from an extra cavity into an intracavity configuration using a sealed-off CO 2 laser as the spectrometer's radiation source. The detection level of the upgrade Intracavity Photoacoustic Spectrometer (IPS) reached (200 ± 50) ppt for C 2 H 4 and (20 ± 5) ppt for SF 6 with response time (6.6 ± 0.2) s. (author)

  4. Functional Enhancements in Used Oil Analysis Spectrometers

    Lukas, Malte

    1998-01-01

    Spark emission spectrometers using the rotating disk electrode (RDE) technique have become the workhorses and primary analytical tool of most machine condition monitoring programs based on oil analysis...

  5. Demonstration of an ethane spectrometer for methane source identification.

    Yacovitch, Tara I; Herndon, Scott C; Roscioli, Joseph R; Floerchinger, Cody; McGovern, Ryan M; Agnese, Michael; Pétron, Gabrielle; Kofler, Jonathan; Sweeney, Colm; Karion, Anna; Conley, Stephen A; Kort, Eric A; Nähle, Lars; Fischer, Marc; Hildebrandt, Lars; Koeth, Johannes; McManus, J Barry; Nelson, David D; Zahniser, Mark S; Kolb, Charles E

    2014-07-15

    Methane is an important greenhouse gas and tropospheric ozone precursor. Simultaneous observation of ethane with methane can help identify specific methane source types. Aerodyne Ethane-Mini spectrometers, employing recently available mid-infrared distributed feedback tunable diode lasers (DFB-TDL), provide 1 s ethane measurements with sub-ppb precision. In this work, an Ethane-Mini spectrometer has been integrated into two mobile sampling platforms, a ground vehicle and a small airplane, and used to measure ethane/methane enhancement ratios downwind of methane sources. Methane emissions with precisely known sources are shown to have ethane/methane enhancement ratios that differ greatly depending on the source type. Large differences between biogenic and thermogenic sources are observed. Variation within thermogenic sources are detected and tabulated. Methane emitters are classified by their expected ethane content. Categories include the following: biogenic (6%), pipeline grade natural gas (30%). Regional scale observations in the Dallas/Fort Worth area of Texas show two distinct ethane/methane enhancement ratios bridged by a transitional region. These results demonstrate the usefulness of continuous and fast ethane measurements in experimental studies of methane emissions, particularly in the oil and natural gas sector.

  6. A mass spectrometer for the rapid analysis of gaseous mixtures

    Cassignol, C.; Ortel, Y.; Taieb, J.

    1950-01-01

    A mass spectrometer for leak detection and rapid gas analysis were constructed, having the characteristics and several structural features of a simple instrument described by Siry in Rev. Sri. Instruments. 540 (1947). Although exhibiting a good resolving power, the apparatus, which has no ion lenses and whose electrodes can be regulated during the performance, has not been sufficiently tested. Since several design defects have been discovered, it will probably be rebuilt with various improvements (ion source outside the magnetic field, modified circuits, etc.). (author)

  7. Process for detecting leak faults using a helium mass spectrometer

    Divet, Claude; Morin, Claude.

    1977-01-01

    The description is given of a process for detecting very small leak faults putting into communication the outer and inner sides of the wall of a containment, one of these wall sides being in contact with gaseous helium under a pressure of around one torr, the other side being one of the limits of a space pumped down to a residual gas pressure under 10 -3 torr. This space is in communication with the measuring cell of a helium mass spectrometer. This process may be applied to the detection of faults in metal claddings of the fuel rods used in nuclear reactors [fr

  8. Time-of-flight spectrometers

    Carrico, J.P.

    1976-01-01

    The flight time of an ion in an inhomogeneous, oscillatory electric field (IOFE) is an m/e-dependent property of this field and is independent of the initial position and velocity. The d.c. component of the equation of motion for an ion in the IOFE describes a harmonic oscillation of constant period. When ions oscillate for many periods with one species overtaking another the motion may no longer be truly periodic although the resulting period or 'quasi-period' still remains independent of the initial conditions. This period or 'quasi-period' is used in the time-of-flight mass spectrometer described. The principle of operation is also described and both analytical and experimental results are reported. (B.D.)

  9. Neutron measurement by transportable spectrometer

    Anon.

    1990-01-01

    Two levels of neutron spectrometry are in regular use at nuclear power plants: some techniques used in the laboratory produce detailed spectra but require specialist operators, while simple instruments used by non-specialists to measure the neutron dose-rate to operators provide little spectral information. The standard portable instruments are therefore of no use when anomalous readings are obtained which require further investigation. AEA Technology at Winfrith has developed a Transportable Neutron Spectrometer (TNS) which is designed to produce reasonable spectra in routine use by staff with no specialist skill in spectroscopy, and high-quality spectra in the hands of skilled staff. The TNS provides a level of information intermediate between those currently available, and is also designed to solve the problem of imperfect dose response which is common in portable dosimeters. The TNS system consists of a power supply, a probe and a signal processing and data acquisition unit. (author)

  10. The BNL multiparticle spectrometer software

    Saulys, A.C.

    1985-01-01

    This paper discusses some solutions to problems common to the design, management and maintenance of a large high energy physics spectrometer software system. The experience of dealing with a large, complex program and the necessity of having the programm controlled by various people at different levels of computer experience has led us to design a program control structure of mnemonic and self-explanatory nature. The use of this control language in both ''on-line'' and ''off-line'' operation of the program will be discussed. The solution of structuring a large program for modularity so that substantial changes to the program can be made easily for a wide variety of high energy physics experiments is discussed. Specialized tools for this type of large program management are also discussed. (orig.)

  11. The Geostationary Fourier Transform Spectrometer

    Key, Richard; Sander, Stanley; Eldering, Annmarie; Blavier, Jean-Francois; Bekker, Dmitriy; Manatt, Ken; Rider, David; Wu, Yen-Hung

    2012-01-01

    The Geostationary Fourier Transform Spectrometer (GeoFTS) is an imaging spectrometer designed for a geostationary orbit (GEO) earth science mission to measure key atmospheric trace gases and process tracers related to climate change and human activity. GEO allows GeoFTS to continuously stare at a region of the earth for frequent sampling to capture the variability of biogenic fluxes and anthropogenic emissions from city to continental spatial scales and temporal scales from diurnal, synoptic, seasonal to interannual. The measurement strategy provides a process based understanding of the carbon cycle from contiguous maps of carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), and chlorophyll fluorescence (CF) collected many times per day at high spatial resolution (2.7kmx2.7km at nadir). The CO2/CH4/CO/CF measurement suite in the near infrared spectral region provides the information needed to disentangle natural and anthropogenic contributions to atmospheric carbon concentrations and to minimize uncertainties in the flow of carbon between the atmosphere and surface. The half meter cube size GeoFTS instrument is based on a Michelson interferometer design that uses all high TRL components in a modular configuration to reduce complexity and cost. It is self-contained and as independent of the spacecraft as possible with simple spacecraft interfaces, making it ideal to be a "hosted" payload on a commercial communications satellite mission. The hosted payload approach for measuring the major carbon-containing gases in the atmosphere from the geostationary vantage point will affordably advance the scientific understating of carbon cycle processes and climate change.

  12. Fluorescence imaging spectrometer optical design

    Taiti, A.; Coppo, P.; Battistelli, E.

    2015-09-01

    The optical design of the FLuORescence Imaging Spectrometer (FLORIS) studied for the Fluorescence Explorer (FLEX) mission is discussed. FLEX is a candidate for the ESA's 8th Earth Explorer opportunity mission. FLORIS is a pushbroom hyperspectral imager foreseen to be embarked on board of a medium size satellite, flying in tandem with Sentinel-3 in a Sun synchronous orbit at a height of about 815 km. FLORIS will observe the vegetation fluorescence and reflectance within a spectral range between 500 and 780 nm. Multi-frames acquisitions on matrix detectors during the satellite movement will allow the production of 2D Earth scene images in two different spectral channels, called HR and LR with spectral resolution of 0.3 and 2 nm respectively. A common fore optics is foreseen to enhance by design the spatial co-registration between the two spectral channels, which have the same ground spatial sampling (300 m) and swath (150 km). An overlapped spectral range between the two channels is also introduced to simplify the spectral coregistration. A compact opto-mechanical solution with all spherical and plane optical elements is proposed, and the most significant design rationales are described. The instrument optical architecture foresees a dual Babinet scrambler, a dioptric telescope and two grating spectrometers (HR and LR), each consisting of a modified Offner configuration. The developed design is robust, stable vs temperature, easy to align, showing very high optical quality along the whole field of view. The system gives also excellent correction for transverse chromatic aberration and distortions (keystone and smile).

  13. Development of a collision induced dissociation ion cyclotron resonance spectrometer

    Fan, Y.N.

    1982-01-01

    A transient analysis ion cyclotron resonance spectrometer is developed to investigate the phenomena of collision induced dissociation. The Fourier transform method and the modified maximum entropy spectral analysis or covariance least square method are implemented in measuring the mass spectrum of the ion ensemble. The Fourier transform method can be used in quantitative analysis while the maximum entropy method as developed here is useful for qualitative analysis only. The cyclotron resonance frequency, relaxation time constant, and the relative ion population are observable from the Fourier transform spectrum. These parameters are very important in investigating collision induced dissociation process and other topics in gas phase chemistry. The ion cyclotron resonance spectrometer is not only developed to study fragments and their abundance from a parent ion, but also to determine the threshold energy and reaction cross section in the collision induced dissociation process. When hard sphere model is used in the ion-molecule collision, the radius of acetone ion measured from the reactive cross section is 2.2 angstrom which is very close to the physical dimension of acetone. The threshold energy for acetone ion in collision induced dissociation process is 1.8 eV which is similar to the result obtained by the angle-resolved mass spectrometer

  14. Advanced mass spectrometers for hydrogen-isotope analyses

    Chastagner, P.; Daves, H.L.; Hess, W.B.

    1982-01-01

    Two advanced mass spectrometers for the accurate analysis of mixtures of the hydrogen isotopes were evaluated by Du Pont personnel at the Savannah River Laboratory. One is a large double-focusing instrument with a resolution of 2000 at mass 4 and an abundance sensitivity of >100,000 for the HT-D 2 doublet. The second is a smaller, simpler, stigmatic focusing instrument with exceptionally high ion intensities (>1 x 10 - 9 A at 600 resolution and about 1 x 10 - 10 A at 1300 resolution) for high signal-to-noise ratios. Both instruments are computer controlled. Once a scan is started, peak switching, scanning, mass discrimination control, data collection, and data reduction are done without operator intervention. Utility routines control hysteresis effects and instrument calibration. A containment facility, with dual inlet systems and a standard distribution system, permits testing with tritium mixtures. Helium flow standards and tritium activity meters provide independent verification of the mass spectrometer calibrations. A recovery system prevents the release of tritium to the environment. The performance of the mass spectrometers was essentially equal under simulated process control conditions. Precision and accuracy for the D/T ratio was <0.5% (rel 2sigma limits). Performance factors were: sample equilibration <300 ppM; linearity within +-0.3%; and gas interference <0.1%. Mass discrimination was controlled reliably by the computers

  15. Computer automated mass spectrometer for isotope analysis on gas samples

    Pamula, A.; Kaucsar, M.; Fatu, C.; Ursu, D.; Vonica, D.; Bendea, D.; Muntean, F.

    1998-01-01

    A low resolution, high precision instrument was designed and realized in the mass spectrometry laboratory of the Institute of Isotopic and Molecular Technology, Cluj-Napoca. The paper presents the vacuum system, the sample inlet system, the ion source, the magnetic analyzer and the ion collector. The instrument is almost completely automated. There are described the analog-to-digital conversion circuits, the local control microcomputer, the automation systems and the performance checking. (authors)

  16. Portable Mass Spectrometer Applications for In Situ Environmental Gas Monitoring

    Griffin, Timothy P.; Diaz, J. Andres; Arkin, C. Richard; Conejo, Elian

    2005-01-01

    Primary Goal of this project is to (1) Design/build a flexible system to monitor air contamination (2) Learn requirements for operating system in low pressure and low temperature environments (3) Design/build system for integration into aircraft and automobiles Secondary Goals/Offshoots are (1) Fly aboard different aircraft (2)Hand-carry unit (3) Drive unit in automobiles.

  17. Atmospheric Transmission Measurements Using IR Lasers, Fourier Transform Spectroscopy, and Gas-Filter Correlation Techniques

    Dowling, J

    1977-01-01

    ... and a gas filter correlation spectrometer. Results obtained from three concurrent experiments used to generate a data base appropriate to high resolution transmission model validation are displayed...

  18. Taiwan university joins search for antimatter

    Chiu, Y

    2002-01-01

    National Cheng Kung University announced yesterday that it will be joining the Alpha Magnetic Spectrometer, an international scientific research project aimed at looking for antimatter in space (1 page).

  19. The MIRI Medium Resolution Spectrometer calibration pipeline

    Labiano, A.; Azzollini, R.; Bailey, J.; Beard, S.; Dicken, D.; García-Marín, M.; Geers, V.; Glasse, A.; Glauser, A.; Gordon, K.; Justtanont, K.; Klaassen, P.; Lahuis, F.; Law, D.; Morrison, J.; Müller, M.; Rieke, G.; Vandenbussche, B.; Wright, G.

    2016-01-01

    The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer (MRS) is the only mid-IR Integral Field Spectrometer on board James Webb Space Telescope. The complexity of the MRS requires a very specialized pipeline, with some specific steps not present in other pipelines of JWST instruments,

  20. Polarized epithermal neutron spectrometer at KENS

    Kohgi, M.

    1983-01-01

    A spectrometer employing a white, epithermal, polarized neutron beam is under construction at KENS. The neutron polarization is achieved by passage through a dynamically polarized proton filter (DPPF). The results of the test experiments show that the DPPF method is promising in obtaining polarized epithermal neutron beam. The basic design of the spectrometer is described

  1. Mass-spectrometer of knock-on nuclei for reactor 'Pik'

    Begzhanov, P.B.; Nazarov, A.G.; Petrov, G.A.; Pikul', V.P.

    1999-01-01

    For reactor 'Pik' (that is being built in St. Petersburg Institute of Nuclear Physics) there was designed a universal two shoulder mass-spectrometer for non-decelerated fission products (FP) of nuclei. The spectrometer helps to obtain different values of linear magnification, dispersion, aberration coefficients and transmission without making structural changes in the device. To separate FP for one shoulder of spectrometer we chose ion-optical scheme (IOS) consisting of three electrostatic analyzers and three-sectional magnet 'JOSEF' that had high dispersion by masses at small deflection radius. IOS calculations of mass-spectrometer were performed with the help of program TRANSVOL (transfer of phase volume) designed basing on TRIO program. The program allows calculating of complete IOS transmission with taking into account elements aperture and beam officering

  2. Knowing what we breathe: Sentinel 4: a geostationary imaging UVN spectrometer for air quality monitoring

    Bazalgette Courrèges-Lacoste, G.; Sallusti, M.; Bulsa, G.; Bagnasco, G.; Gulde, S.; Kolm, M. G.; Smith, D. J.; Maurer, R.

    2017-09-01

    Sentinel-4 is an imaging UVN (UV-VIS-NIR) spectrometer, developed by Airbus DS under ESA contract in the frame of the joint EU/ESA COPERNICUS program. The mission objective is the operational monitoring of trace gas concentrations for atmospheric chemistry and climate applications - hence the motto of Sentinel-4 "Knowing what we breathe".

  3. Large solid-angle spectrometers for studies of double-differential charged-particle and neutron emission cross sections

    Baba, M.; Matsuyama, S.; Sanami, T.; Soda, D.; Matsuyama, I.; Ohkubo, T.; Iwasaki, S.; Hirakawa, N.

    1995-01-01

    The large solid-angle spectrometer developed for studies of double-differential cross sections of (n, charged particle) and (n, xn') reactions using a gas-filled gridded-ionization chamber and an 80-cm long liquid scintillator is described. The charged particle spectrometer is a twin gas-filled gridded-ionization chamber with solid angle close to 4 π designed to achieve high stopping power and background suppression. The neutron spectrometer is a long NE213 liquid scintillation detector having position sensitivity. It is used as a large single spectrometer or a position sensitive detector covering wide scattering angle. The facility design, performance and examples of application are discussed. The conclusion is made that the facility provides a useful mean for studies in particular for reactions with small cross sections and/or for neutron sources with low intensity. 15 refs., 15 figs

  4. Mobility Spectrometer Studies on Hydrazine and Ammonia Detection

    Niu, William; Eiceman, Gary; Szumlas, Andrew; Lewis, John

    2011-01-01

    An airborne vapor analyzer for detecting sub- to low- parts-per-million (ppm) hydrazine in the presence of higher concentration levels of ammonia has been under development for the Orion program. The detector is based on ambient pressure ionization and ion mobility characterization. The detector encompasses: 1) a membrane inlet to exclude particulate and aerosols from the analyzer inlet; 2) a method to separate hydrazine from ammonia which would otherwise lead to loss of calibration and quantitative accuracy for the hydrazine determination; and 3) response and quantitative determinations for both hydrazine and ammonia. Laboratory studies were made to explore some of these features including mobility measurements mindful of power, size, and weight issues. The study recommended the use of a mobility spectrometer of traditional design with a reagent gas and equipped with an inlet transfer line of bonded phase fused silica tube. The inlet transfer line provided gas phase separation of neutrals of ammonia from hydrazine at 50 C simplifying significantly the ionization chemistry that underlies response in a mobility spectrometer. Performance of the analyzer was acceptable between ranges of 30 to 80 C for both the pre-fractionation column and the drift tube. An inlet comprised of a combined membrane with valve-less injector allowed high speed quantitative determination of ammonia and hydrazine without cross reactivity from common metabolites such as alcohols, esters, and aldehydes. Preliminary test results and some of the design features are discussed.

  5. Handheld spectrometers: the state of the art

    Crocombe, Richard A.

    2013-05-01

    "Small" spectrometers fall into three broad classes: small versions of laboratory instruments, providing data, subsequently processed on a PC; dedicated analyzers, providing actionable information to an individual operator; and process analyzers, providing quantitative or semi-quantitative information to a process controller. The emphasis of this paper is on handheld dedicated analyzers. Many spectrometers have historically been large, possible fragile, expensive and complicated to use. The challenge over the last dozen years, as instruments have moved into the field, has been to make spectrometers smaller, affordable, rugged, easy-to-use, but most of all capable of delivering actionable results. Actionable results can dramatically improve the efficiency of a testing process and transform the way business is done. There are several keys to this handheld spectrometer revolution. Consumer electronics has given us powerful mobile platforms, compact batteries, clearly visible displays, new user interfaces, etc., while telecomm has revolutionized miniature optics, sources and detectors. While these technologies enable miniature spectrometers themselves, actionable information has demanded the development of rugged algorithms for material confirmation, unknown identification, mixture analysis and detection of suspicious materials in unknown matrices. These algorithms are far more sophisticated than the `correlation' or `dot-product' methods commonly used in benchtop instruments. Finally, continuing consumer electronics advances now enable many more technologies to be incorporated into handheld spectrometers, including Bluetooth, wireless, WiFi, GPS, cameras and bar code readers, and the continued size shrinkage of spectrometer `engines' leads to the prospect of dual technology or `hyphenated' handheld instruments.

  6. GIOVE, a shallow laboratory Ge-spectrometer with 100 μBq/kg sensitivity

    Heusser, G.; Weber, M.; Denz, T.; Hakenmueller, J.; Hofacker, R.; Lackner, R.; Lindner, M.; Maneschg, W.; Reisfelder, M.; Simgen, H.; Schreiner, J.; Stolzenburg, D.; Strecker, H.; Westermann, J. [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany)

    2013-08-08

    A new germanium gamma spectrometer called GIOVE (Germanium spectrometer with Inner and Outer Veto) has been set up at the underground/shallow laboratory (15 m w.e.) of MPI-K. Its double plastic scintillator veto system and neutron moderation interlayer lower the background by more than one order of magnitude compared to the other existing spectrometer at this facility. The integral (40-2700 keV) background rate of about 290 counts (day kg){sup −1} is just a factor 4 to 8 above that of the GeMPI spectrometers operated at LNGS (3800 m w.e.) and thus proves that even under shallow overburden sub mBq/kg sensitivities are achievable. Extended material screening and neutron attenuation studies preceded the final design of the spectrometer. The technical realization of the spectrometer is described in detail with special emphasis on the inner veto system. For its optimisation a simulation model was developed for light collection on small low activity PMT’s under various geometrical conditions. Radon suppression is accomplished by employing a gas tight sample container and a nitrogen flushed glove-box system with an airlock. The active volume of the crystal was modelled by absorption scanning measurements and Monte Carlo simulations. The complete shield is implemented in a Geant4 based simulation framework.

  7. High-Resolution Mass Spectrometers

    Marshall, Alan G.; Hendrickson, Christopher L.

    2008-07-01

    Over the past decade, mass spectrometry has been revolutionized by access to instruments of increasingly high mass-resolving power. For small molecules up to ˜400 Da (e.g., drugs, metabolites, and various natural organic mixtures ranging from foods to petroleum), it is possible to determine elemental compositions (CcHhNnOoSsPp…) of thousands of chemical components simultaneously from accurate mass measurements (the same can be done up to 1000 Da if additional information is included). At higher mass, it becomes possible to identify proteins (including posttranslational modifications) from proteolytic peptides, as well as lipids, glycoconjugates, and other biological components. At even higher mass (˜100,000 Da or higher), it is possible to characterize posttranslational modifications of intact proteins and to map the binding surfaces of large biomolecule complexes. Here we review the principles and techniques of the highest-resolution analytical mass spectrometers (time-of-flight and Fourier transform ion cyclotron resonance and orbitrap mass analyzers) and describe some representative high-resolution applications.

  8. A semiconductor beta ray spectrometer

    Bom, V.R.

    1987-01-01

    Measurement of energy spectra of beta particles emitted from nuclei in beta-decay processes provides information concerning the mass difference of these nuclei between initial and final state. Moreover, experimental beta spectra yield information on the feeding of the levels in the daughter nucleus. Such data are valuable in the construction and checking of the level schemes. This thesis describes the design, construction, testing and usage of a detector for the accurate measurement of the mentioned spectra. In ch. 2 the design and construction of the beta spectrometer, which uses a hyper-pure germanium crystal for energy determination, is described. A simple wire chamber is used to discriminate beta particles from gamma radiation. Disadvantages arise from the large amounts of scattered beta particles deforming the continua. A method is described to minimize the scattering. In ch. 3 some theoretical aspects of data analysis are described and the results of Monte-Carlo simulations of the summation of annihilation radiation are compared with experiments. Ch. 4 comprises the results of the measurements of the beta decay energies of 103-108 In. 87 refs.; 34 figs.; 7 tabs

  9. High intensity TOF spectrometer for cold neutrons

    Maayouf, R.M.; Abd El-Kawy, A.; Habib, N.; Adib, M.; Hamouda, I.

    1984-01-01

    This work presents a neutron time-of-flight (TOF) spectrometer developed specially for total neutron cross-section measurements at neutron energies below 5 MeV and sample's temperature varying from the liquid nitrogen one and up to 500 0 K. The spectrometer is equipped by remote control unit, designed especially, in order to move the sample in and out of the beam during the experimental measurements. The spectrometer has proved to be useful for transmission measurements at neutron energies below 5 MeV. It has a reasonable energy resolution (4.4%) and high effect to background ratio (11.1) at 5 MeV

  10. RITA: The reinvented triple axis spectrometer

    Mason, T.E. [Toronto Univ., ON (Canada). Dept. of Physics; Clausen, K.N.; Aeppli, G.; McMorrow, D.R.; Kjems, J.K. [Risoe National Lab., Roskilde (Denmark)

    1995-11-01

    Risoe National Laboratory was reported to be in the process of developing a new spectrometer design, RITA, based on the triple axis design. The spectrometer will attempt to incorporate more recent innovations such as multilayer supermirrors and microstrip proportional counters into a rethinking of the triple-axis spectrometer. By optimizing the beam optics, using supermirrors and extending the analyser to map regions of (Q, {omega}) space using an array of independently controllable pyrolytic graphite crystals focussed on an area detector, it was hoped that the efficiency of single-crystal inelastic experiments could be increased by as much as a factor of 20. 7 figs., 20 refs.

  11. Method for selective detection of explosives in mass spectrometer or ion mobility spectrometer at parts-per-quadrillion level

    Ewing, Robert G.; Atkinson, David A.; Clowers, Brian H.

    2015-09-01

    A method for selective detection of volatile and non-volatile explosives in a mass spectrometer or ion mobility spectrometer at a parts-per-quadrillion level without preconcentration is disclosed. The method comprises the steps of ionizing a carrier gas with an ionization source to form reactant ions or reactant adduct ions comprising nitrate ions (NO.sub.3.sup.-); selectively reacting the reactant ions or reactant adduct ions with at least one volatile or non-volatile explosive analyte at a carrier gas pressure of at least about 100 Ton in a reaction region disposed between the ionization source and an ion detector, the reaction region having a length which provides a residence time (tr) for reactant ions therein of at least about 0.10 seconds, wherein the selective reaction yields product ions comprising reactant ions or reactant adduct ions that are selectively bound to the at least one explosive analyte when present therein; and detecting product ions with the ion detector to determine presence or absence of the at least one explosive analyte.

  12. Gas and Gas Pains

    ... to produce gas. Often, relatively simple changes in eating habits can lessen bothersome gas. Certain digestive system disorders, ... such as soda and beer, increase stomach gas. Eating habits, such as eating too quickly, drinking through a ...

  13. 40Ar/39Ar dating of Quaternary volcanic ashes by multi-collection noble gas mass spectrometry: protocols, precision and intercalibration

    Storey, Michael; Rivera, Tiffany; Flude, Stephanie

    ) higher mass resolution allows hydrocarbon interferences to be pseudo resolved for the different argon isotopes; and (iv) multi-collection, allowing more data to be gathered in a fixed time in comparison with single-collector peak-switching measurements. We evaluate (i) protocols for detector inter......The recent availability of commercial high-resolution, multi-collector, noble gas mass spectrometers equipped with ion-counting electron multipliers provides new opportunities for improved precision in 40Ar/39Ar dating. This is particularly true for single crystal dating of Quaternary aged samples...... where potassium-bearing phenocrysts may contain relatively small amounts of radiogenic 40Ar. In 2005, the Quaternary Dating Laboratory, Roskilde University, installed a Nu-Instruments multi-collector Noblesse noble gas mass spectrometer, which is configured with a Faraday detector and three ion...

  14. Multidetector calibration for mass spectrometers

    Bayne, C.K.; Donohue, D.L.; Fiedler, R.

    1994-06-01

    The International Atomic Energy Agency's Safeguards Analytical Laboratory has performed calibration experiments to measure the different efficiencies among multi-Faraday detectors for a Finnigan-MAT 261 mass spectrometer. Two types of calibration experiments were performed: (1) peak-shift experiments and (2) peak-jump experiments. For peak-shift experiments, the ion intensities were measured for all isotopes of an element in different Faraday detectors. Repeated measurements were made by shifting the isotopes to various Faraday detectors. Two different peak-shifting schemes were used to measure plutonium (UK Pu5/92138) samples. For peak-jump experiments, ion intensities were measured in a reference Faraday detector for a single isotope and compared with those measured in the other Faraday detectors. Repeated measurements were made by switching back-and-forth between the reference Faraday detector and a selected Faraday detector. This switching procedure is repeated for all Faraday detectors. Peak-jump experiments were performed with replicate measurements of 239 Pu, 187 Re, and 238 U. Detector efficiency factors were estimated for both peak-jump and peak-shift experiments using a flexible calibration model to statistically analyze both types of multidetector calibration experiments. Calculated detector efficiency factors were shown to depend on both the material analyzed and the experimental conditions. A single detector efficiency factor is not recommended for each detector that would be used to correct routine sample analyses. An alternative three-run peak-shift sample analysis should be considered. A statistical analysis of the data from this peak-shift experiment can adjust the isotopic ratio estimates for detector differences due to each sample analysis

  15. The VERDI fission fragment spectrometer

    Frégeau M.O.

    2013-12-01

    Full Text Available The VERDI time-of-flight spectrometer is dedicated to measurements of fission product yields and of prompt neutron emission data. Pre-neutron fission-fragment masses will be determined by the double time-of-flight (TOF technique. For this purpose an excellent time resolution is required. The time of flight of the fragments will be measured by electrostatic mirrors located near the target and the time signal coming from silicon detectors located at 50 cm on both sides of the target. This configuration, where the stop detector will provide us simultaneously with the kinetic energy of the fragment and timing information, significantly limits energy straggling in comparison to legacy experimental setup where a thin foil was usually used as a stop detector. In order to improve timing resolution, neutron transmutation doped silicon will be used. The high resistivity homogeneity of this material should significantly improve resolution in comparison to standard silicon detectors. Post-neutron fission fragment masses are obtained form the time-of-flight and the energy signal in the silicon detector. As an intermediary step a diamond detector will also be used as start detector located very close to the target. Previous tests have shown that poly-crystalline chemical vapour deposition (pCVD diamonds provides a coincidence time resolution of 150 ps not allowing complete separation between very low-energy fission fragments, alpha particles and noise. New results from using artificial single-crystal diamonds (sCVD show similar time resolution as from pCVD diamonds but also sufficiently good energy resolution.

  16. Performance of drift chambers in a magnetic rigidity spectrometer for measuring the cosmic radiation

    Hof, M.; Bremerich, M.; Menn, W.; Pfeifer, C.; Reimer, O.; Simon, M.; Mitchell, J.W.; Barbier, L.M.; Christian, E.R.; Ormes, J.F.; Streitmatter, R.E.; Golden, R.L.; Stochaj, S.J.

    1994-01-01

    A drift chamber tracking system was developed and flown as part of the IMAX balloon-borne magnetic spectrometer. The drift chamber uses a hexagonal drift-cell structure and is filled with pure CO 2 gas. It operated with high efficiency in the strong and inhomogenous field of a superconducting magnet, demonstrating a spatial resolution of better than 100 μm over most of the drift path for singly charged particles, as well as for helium and lithium nuclei. The drift chamber portion of the spectrometer achieved a maximum detectable rigidity of 175 and 250 GV/c for protons and helium respectively. ((orig.))

  17. Investigation of material systems in industry and research by organic analytical mass spectrometer

    Decsy, Z.

    1980-01-01

    The modern, many-sided and efficient organic analytical mass spectrometer possesses all the structure-and composition-examination possibilities of complex organic analytical laboratories. The article presents the advantages and possibilities of the application of mass spectrometer in different operation modes in connection with the examination of a petrochemical synthesis product: ortho-phenylene-diamine, an experimental gas odorizing material, a petroleum production auxiliary material: petroleum sulfonate, a gasoline sample and a sulfur-containing standard substance. The useful operation modes include spectrum records of low and high resolution, the application of space ionization and space desorption ion sources as well as the ''mass fragmentographic'' measuring method. (author)

  18. Precise mass measurements of exotic nuclei--the SHIPTRAP Penning trap mass spectrometer

    Herfurth, F.; Ackermann, D.; Block, M.; Dworschak, M.; Eliseev, S.; Hessberger, F.; Hofmann, S.; Kluge, H.-J.; Maero, G.; Martin, A.; Mazzocco, M.; Rauth, C.; Vorobjev, G.; Blaum, K.; Ferrer, R.; Neidherr, D.; Chaudhuri, A.; Marx, G.; Schweikhard, L.; Neumayr, J.

    2007-01-01

    The SHIPTRAP Penning trap mass spectrometer has been designed and constructed to measure the mass of short-lived, radioactive nuclei. The radioactive nuclei are produced in fusion-evaporation reactions and separated in flight with the velocity filter SHIP at GSI in Darmstadt. They are captured in a gas cell and transfered to a double Penning trap mass spectrometer. There, the cyclotron frequencies of the radioactive ions are determined and yield mass values with uncertainties ≥4.5·10 -8 . More than 50 nuclei have been investigated so far with the present overall efficiency of about 0.5 to 2%

  19. At the European Hybrid Spectrometer (EHS) for the experiment NA27

    1983-01-01

    The experiment NA27 was intended to measure accurately the lifetime of Charm particles and to study their hadronic production and decay particles. The vertex detector was the hydrogen bubble chamber LEBC. The aim was to collect several hundreths of fully reconstructed D0 and D+-, and several tens of F+- and Lambda_c decays as produced by 360 GeV/c negative pions and 400 GeV/c protons. The photo gives a side view of a section of the spectrometer, with a 12 m long gas Cerenkov counter at the centre. The spectrometer axis enters the photo at bottom, left corner. See photo 8311661, 8311662X, 8311660X.

  20. View of the Axial Field Spectrometer

    1980-01-01

    The Axial Field Spectrometer, with the vertical uranium/scintillator calorimeter and the central drift chamber retracted for service. One coil of the Open Axial Field Magnet is just visible to the right.

  1. ISLA: An Isochronous Spectrometer with Large Acceptances

    Bazin, D., E-mail: bazin@nscl.msu.edu; Mittig, W.

    2013-12-15

    A novel type of recoil mass spectrometer and separator is proposed for the future secondary radioactive beams of the ReA12 accelerator at NSCL/FRIB, inspired from the TOFI spectrometer developed at the Los Alamos National Laboratory for online mass measurements. The Isochronous Spectrometer with Large Acceptances (ISLA) is able to achieve superior characteristics without the compromises that usually plague the design of large acceptance spectrometers. ISLA can provide mass-to-charge ratio (m/q) measurements to better than 1 part in 1000 by using an optically isochronous time-of-flight independent of the momentum vector of the recoiling ions, despite large acceptances of 20% in momentum and 64 msr in solid angle. The characteristics of this unique design are shown, including requirements for auxiliary detectors around the target and the various types of reactions to be used with the re-accelerated radioactive beams of the future ReA12 accelerator.

  2. Computer control in a compton scattering spectrometer

    Cui Ningzhuo; Chen Tao; Gong Zhufang; Yang Baozhong; Mo Haiding; Hua Wei; Bian Zuhe

    1995-01-01

    The authors introduced the hardware and software of computer autocontrol of calibration and data acquisition in a Compton Scattering spectrometer which consists of a HPGe detector, Amplifiers and a MCA

  3. Electrostatic Spectrometer for Mars Rover Wheel

    National Aeronautics and Space Administration — Develop a simple electrostatic spectrometer that can be mounted on the wheels of a Mars rover to continuously and unobtrusively determine the mineral composition and...

  4. Low Power FPGA Based Spectrometer, Phase I

    National Aeronautics and Space Administration — We propose to design a general purpose reconfigurable wide bandwidth spectrometer for use in NASA's passive microwave missions, deep space network and radio...

  5. High-resolution spectrometer at PEP

    Weiss, J.M.; HRS Collaboration.

    1982-01-01

    A description is presented of the High Resolution Spectrometer experiment (PEP-12) now running at PEP. The advanced capabilities of the detector are demonstrated with first physics results expected in the coming months

  6. Remote UV Fluorescence Lifetime Spectrometer, Phase II

    National Aeronautics and Space Administration — The goal of this project is to develop, demonstrate, and deliver to NASA an innovative, portable, and power efficient Remote UV Fluorescence Lifetime Spectrometer...

  7. The electronic system of Beijing spectrometer

    Xi Deming

    1990-01-01

    Beijing Spectrometer (BES) in an experimental facility of high energy physics on Beijing Electron Positron Collider (BEPC). A brief description including the global design, the read out circuits, the performances and the recent status of its electronic system is presented

  8. RITA-type triple axis spectrometers

    Roennow, H.M.

    2001-01-01

    The RITA spectrometer at Risoe National Laboratory was the first to incorporate a complete re-thinking of the neutron-path from source, through detector to analysis. Since then, other RITA-type spectrometers such as SPINS at NIST, RITA-II at PSI have been built, and several new spectrometers around the world are adapting the same philosophy. The main novelty of RITA was the introduction of a single back-end tank featuring both an analyser block with multiple individually turnable analyser blades and a 2D position sensitive detector. Several new triple-axis spectrometers are presently being built at existing and future sources, and almost all of them have learnt from the experience with RITA. (R.P.)

  9. Studies Related to the Oregon State University High Temperature Test Facility: Scaling, the Validation Matrix, and Similarities to the Modular High Temperature Gas-Cooled Reactor

    Richard R. Schultz; Paul D. Bayless; Richard W. Johnson; William T. Taitano; James R. Wolf; Glenn E. McCreery

    2010-09-01

    The Oregon State University (OSU) High Temperature Test Facility (HTTF) is an integral experimental facility that will be constructed on the OSU campus in Corvallis, Oregon. The HTTF project was initiated, by the U.S. Nuclear Regulatory Commission (NRC), on September 5, 2008 as Task 4 of the 5 year High Temperature Gas Reactor Cooperative Agreement via NRC Contract 04-08-138. Until August, 2010, when a DOE contract was initiated to fund additional capabilities for the HTTF project, all of the funding support for the HTTF was provided by the NRC via their cooperative agreement. The U.S. Department of Energy (DOE) began their involvement with the HTTF project in late 2009 via the Next Generation Nuclear Plant project. Because the NRC interests in HTTF experiments were only centered on the depressurized conduction cooldown (DCC) scenario, NGNP involvement focused on expanding the experimental envelope of the HTTF to include steady-state operations and also the pressurized conduction cooldown (PCC). Since DOE has incorporated the HTTF as an ingredient in the NGNP thermal-fluids validation program, several important outcomes should be noted: 1. The reference prismatic reactor design, that serves as the basis for scaling the HTTF, became the modular high temperature gas-cooled reactor (MHTGR). The MHTGR has also been chosen as the reference design for all of the other NGNP thermal-fluid experiments. 2. The NGNP validation matrix is being planned using the same scaling strategy that has been implemented to design the HTTF, i.e., the hierarchical two-tiered scaling methodology developed by Zuber in 1991. Using this approach a preliminary validation matrix has been designed that integrates the HTTF experiments with the other experiments planned for the NGNP thermal-fluids verification and validation project. 3. Initial analyses showed that the inherent power capability of the OSU infrastructure, which only allowed a total operational facility power capability of 0.6 MW, is

  10. Design and construction of a NIR spectrometer

    Barcala-Riveira, J M; Fernandez-Marron, J L; Molero-Menendez, F; Navarrete-Marin, J J; Oller-Gonzalez, J C

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs.

  11. Silicon spectrometer with a Peltier refrigerator

    Belcarz, E.; Chwaszczewska, J.; Hahn, G.; Nowicki, W.; Sawicka, B.; Skoczek, K.; Slapa, M.; Szymczak, M.

    1974-01-01

    This paper describes a spectrometer with a Si(Li) detector cooled by a Peltier refrigerator. The spectrometer is able to analyse samples of practically all most frequently encountered emitters of alpha, beta and low energy gamma radiation. The energy resolution were about 1.3-1.5 keV for 14 keV gamma radiation. The system can also operate in field conditions in the fluorescence analysis. (author)

  12. Design and construction of a NIR spectrometer

    Barcala Riveira, J. M.; Fernandez Marron, J. L.; Alberdi Primicia, J.; Molero Menendez, F.; Navarrete Marin, J. J.; Oller Gonzalez, J. C.

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs

  13. 1987 calibration of the TFTR neutron spectrometers

    Barnes, C.W.; Strachan, J.D.; Princeton Univ., NJ

    1989-12-01

    The 3 He neutron spectrometer used for measuring ion temperatures and the NE213 proton recoil spectrometer used for triton burnup measurements were absolutely calibrated with DT and DD neutron generators placed inside the TFTR vacuum vessel. The details of the detector response and calibration are presented. Comparisons are made to the neutron source strengths measured from other calibrated systems. 23 refs., 19 figs., 6 tabs

  14. Fast-response personal Moessbauer spectrometer

    Kholmetskij, A.L.; Mashlan, M.; Misevich, O.V.; Evdokimov, V.A.; Lopatik, A.R.; Zhak, D.; Fedorov, A.A.; Snashel, V.

    1995-01-01

    Spectrometer design to record transmission Moessbauer spectra is described. The spectrometer consists of PC/AT computer with 1 mb memory and 40 mb hard disk, of EPSON LX 850 printer, of color monitor with VGA graphical adapter, of data accumulation system, of speed generator, of motion system with minivibrator, of scintillation detector with YA10 3 :Ce scintillator, of single-channel amplitude analyzer, of measuring bench and of 57 Co(Rh) source. 1 ref.; 1 fig

  15. The BTeV main spectrometer

    Sheldon, P.D.

    2001-01-01

    BTeV is a second generation B-factory experiment that will use a double-arm, forward spectrometer in the C0 experimental hall at the Fermilab Tevatron. I will describe the motivation and design of the 'main spectrometer', consisting of a ring-imaging Cherenkov system for charged particle identification, an electromagnetic calorimeter of lead-tungstate crystals, a proportional tube muon system with magnetized filtering steel, and a straw-tube and silicon strip charged particle tracking system

  16. Recent ion optics and mass spectrometers

    Matsuda, Hisashi

    1976-01-01

    The establishment of the third order approximation method for computing the orbit of the ion optical system for mass spectrometers and the completion of its computer program are reported. A feature of this orbit computation is in that the effect of the fringing field can be considered with the accuracy of third order approximation. Several new ion optical systems for mass spectrometers have been proposed by using such orbit computing programs. Brief explanation and the description on the future prospect and problems are made on the following items: the vertual image double focusing mass spectrometer, the second order double focusing mass spectrometer, the E x B superposed field mass spectrometer, and the apparatus with a cylindrical electric field and Q-lens. In the E x B superposed field with Matsuda plates, if the magnetic field is generated by an electromagnet instead of a permanent magnet, the dispersion of mass and energy can be changed at will. The Matsuda plates are known as the auxiliary electrodes positioned at the top and bottom of a cylindrical capacitor. Utilizing those characteristics, a zoom spectrometer can be made, with which only a necessary part of mass spectra can be investigated in detail, but the whole spectra are investigated roughly. In addition, the distribution of energy can be investigated simultaneously after the separation of ionic mass similarly to the parabola apparatus. (Iwakiri, K.)

  17. Study of neutron spectrometers for ITER

    Kaellne, Jan

    2005-11-15

    A review is presented of the developments in the field of neutron emission spectrometry (NES) which is of relevance for identifying the role of NES diagnostics on ITER and selecting suitable instrumentation. Neutron spectrometers will be part of the ITER neutron diagnostic complement and this study makes a special effort to examine which performance characteristics the spectrometers should possess to provide the best burning plasma diagnostic information together with neutron cameras and neutron yield monitors. The performance of NES diagnostics is coupled to how much interface space can be provided which has lead to an interest to find compact instruments and their NES capabilities. This study assesses all known spectrometer types of potential interest for ITER and makes a ranking of their performance (as demonstrated or projected), which, in turn, are compared with ITER measurement requirements as a reference; the ratio of diagnostic performance to interface cost for different spectrometers is also discussed for different spectrometer types. The overall result of the study is an assessment of which diagnostic functions neutron measurements can provide in burning plasma fusion experiments on ITER and the role that NES can play depending on the category of instrument installed. Of special note is the result that much higher quality diagnostic information can be obtained from neutron measurements with total yield monitors, profile flux cameras and spectrometers when the synergy in the data is considered in the analysis and interpretation.

  18. Semiconductor X-ray spectrometers

    Muggleton, A.H.F.

    1978-02-01

    An outline is given of recent developments in particle and photon induced x-ray fluorescence (XRF) analysis. Following a brief description of the basic mechanism of semiconductor detector operation a comparison is made between semiconductor detectors, scintillators and gas filled proportional devices. Detector fabrication and cryostat design are described in more detail and the effects of various device parameters on system performance, such as energy resolution, count rate capability, efficiency, microphony, etc. are discussed. The main applications of these detectors in x-ray fluorescence analysis, electron microprobe analysis, medical and pollution studies are reviewed

  19. Improved Cloud Condensation Nucleus Spectrometer

    Leu, Ming-Taun

    2010-01-01

    An improved thermal-gradient cloud condensation nucleus spectrometer (CCNS) has been designed to provide several enhancements over prior thermal- gradient counters, including fast response and high-sensitivity detection covering a wide range of supersaturations. CCNSs are used in laboratory research on the relationships among aerosols, supersaturation of air, and the formation of clouds. The operational characteristics of prior counters are such that it takes long times to determine aerosol critical supersaturations. Hence, there is a need for a CCNS capable of rapid scanning through a wide range of supersaturations. The present improved CCNS satisfies this need. The improved thermal-gradient CCNS (see Figure 1) incorporates the following notable features: a) The main chamber is bounded on the top and bottom by parallel thick copper plates, which are joined by a thermally conductive vertical wall on one side and a thermally nonconductive wall on the opposite side. b) To establish a temperature gradient needed to establish a supersaturation gradient, water at two different regulated temperatures is pumped through tubes along the edges of the copper plates at the thermally-nonconductive-wall side. Figure 2 presents an example of temperature and supersaturation gradients for one combination of regulated temperatures at the thermally-nonconductive-wall edges of the copper plates. c) To enable measurement of the temperature gradient, ten thermocouples are cemented to the external surfaces of the copper plates (five on the top plate and five on the bottom plate), spaced at equal intervals along the width axis of the main chamber near the outlet end. d) Pieces of filter paper or cotton felt are cemented onto the interior surfaces of the copper plates and, prior to each experimental run, are saturated with water to establish a supersaturation field inside the main chamber. e) A flow of monodisperse aerosol and a dilution flow of humid air are introduced into the main

  20. Application of the mass-spectrometer MASHA for mass-spectrometry and laser-spectroscopy

    Rodin, A. M.; Belozerov, A. V.; Dmitriev, S. N.; Oganessian, Yu. Ts.; Sagaidak, R. N.; Salamatin, V. S.; Stepantsov, S. V.; Vanin, D. V.

    2010-02-01

    We report the present status of the mass-spectrometer MASHA (Mass-Analyzer of Supper Heavy Atoms) designed for determination of the masses of superheavy elements. The mass-spectrometer is connected to the U-400M cyclotron of the Flerov Laboratory for Nuclear Reactions (FLNR) JINR, Dubna. The first experiments on mass-measurements for 112 and 114 elements will be performed in the upcoming 2010. For this purpose a hot catcher, based on a graphite stopper, is constructed. The α-decay of the superheavy nuclides or spontaneous fission products will be detected with a silicon 192 strips detector. The experimental program of future investigations using the technique of a gas catcher is discussed. It should be regarded as an alternative of the classical ISOL technique. The possibilities are considered for using this mass-spectrometer for laser spectroscopy of nuclei far off-stability.

  1. Application of the mass-spectrometer MASHA for mass-spectrometry and laser-spectroscopy

    Rodin, A. M.; Belozerov, A. V.; Dmitriev, S. N.; Oganessian, Yu. Ts.; Sagaidak, R. N.; Salamatin, V. S.; Stepantsov, S. V.; Vanin, D. V.

    2010-01-01

    We report the present status of the mass-spectrometer MASHA (Mass-Analyzer of Supper Heavy Atoms) designed for determination of the masses of superheavy elements. The mass-spectrometer is connected to the U-400M cyclotron of the Flerov Laboratory for Nuclear Reactions (FLNR) JINR, Dubna. The first experiments on mass-measurements for 112 and 114 elements will be performed in the upcoming 2010. For this purpose a hot catcher, based on a graphite stopper, is constructed. The α-decay of the superheavy nuclides or spontaneous fission products will be detected with a silicon 192 strips detector. The experimental program of future investigations using the technique of a gas catcher is discussed. It should be regarded as an alternative of the classical ISOL technique. The possibilities are considered for using this mass-spectrometer for laser spectroscopy of nuclei far off-stability.

  2. Application of the mass-spectrometer MASHA for mass-spectrometry and laser-spectroscopy

    Rodin, A. M., E-mail: rodin@nrmail.jinr.ru; Belozerov, A. V.; Dmitriev, S. N.; Oganessian, Yu. Ts.; Sagaidak, R. N.; Salamatin, V. S.; Stepantsov, S. V.; Vanin, D. V. [JINR, Flerov Laboratory of Nuclear Reactions (Russian Federation)

    2010-02-15

    We report the present status of the mass-spectrometer MASHA (Mass-Analyzer of Supper Heavy Atoms) designed for determination of the masses of superheavy elements. The mass-spectrometer is connected to the U-400M cyclotron of the Flerov Laboratory for Nuclear Reactions (FLNR) JINR, Dubna. The first experiments on mass-measurements for 112 and 114 elements will be performed in the upcoming 2010. For this purpose a hot catcher, based on a graphite stopper, is constructed. The {alpha}-decay of the superheavy nuclides or spontaneous fission products will be detected with a silicon 192 strips detector. The experimental program of future investigations using the technique of a gas catcher is discussed. It should be regarded as an alternative of the classical ISOL technique. The possibilities are considered for using this mass-spectrometer for laser spectroscopy of nuclei far off-stability.

  3. The LASS [Larger Aperture Superconducting Solenoid] spectrometer

    Aston, D.; Awaji, N.; Barnett, B.

    1986-04-01

    LASS is the acronym for the Large Aperture Superconducting Solenoid spectrometer which is located in an rf-separated hadron beam at the Stanford Linear Accelerator Center. This spectrometer was constructed in order to perform high statistics studies of multiparticle final states produced in hadron reactions. Such reactions are frequently characterized by events having complicated topologies and/or relatively high particle multiplicity. Their detailed study requires a spectrometer which can provide good resolution in momentum and position over almost the entire solid angle subtended by the production point. In addition, good final state particle identification must be available so that separation of the many kinematically-overlapping final states can be achieved. Precise analyses of the individual reaction channels require high statistics, so that the spectrometer must be capable of high data-taking rates in order that such samples can be acquired in a reasonable running time. Finally, the spectrometer must be complemented by a sophisticated off-line analysis package which efficiently finds tracks, recognizes and fits event topologies and correctly associates the available particle identification information. This, together with complicated programs which perform specific analysis tasks such as partial wave analysis, requires a great deal of software effort allied to a very large computing capacity. This paper describes the construction and performance of the LASS spectrometer, which is an attempt to realize the features just discussed. The configuration of the spectrometer corresponds to the data-taking on K + and K - interactions in hydrogen at 11 GeV/c which took place in 1981 and 1982. This constitutes a major upgrade of the configuration used to acquire lower statistics data on 11 GeV/c K - p interactions during 1977 and 1978, which is also described briefly

  4. The LASS (Larger Aperture Superconducting Solenoid) spectrometer

    Aston, D.; Awaji, N.; Barnett, B.; Bienz, T.; Bierce, R.; Bird, F.; Bird, L.; Blockus, D.; Carnegie, R.K.; Chien, C.Y.

    1986-04-01

    LASS is the acronym for the Large Aperture Superconducting Solenoid spectrometer which is located in an rf-separated hadron beam at the Stanford Linear Accelerator Center. This spectrometer was constructed in order to perform high statistics studies of multiparticle final states produced in hadron reactions. Such reactions are frequently characterized by events having complicated topologies and/or relatively high particle multiplicity. Their detailed study requires a spectrometer which can provide good resolution in momentum and position over almost the entire solid angle subtended by the production point. In addition, good final state particle identification must be available so that separation of the many kinematically-overlapping final states can be achieved. Precise analyses of the individual reaction channels require high statistics, so that the spectrometer must be capable of high data-taking rates in order that such samples can be acquired in a reasonable running time. Finally, the spectrometer must be complemented by a sophisticated off-line analysis package which efficiently finds tracks, recognizes and fits event topologies and correctly associates the available particle identification information. This, together with complicated programs which perform specific analysis tasks such as partial wave analysis, requires a great deal of software effort allied to a very large computing capacity. This paper describes the construction and performance of the LASS spectrometer, which is an attempt to realize the features just discussed. The configuration of the spectrometer corresponds to the data-taking on K and K interactions in hydrogen at 11 GeV/c which took place in 1981 and 1982. This constitutes a major upgrade of the configuration used to acquire lower statistics data on 11 GeV/c K p interactions during 1977 and 1978, which is also described briefly.

  5. Proceedings of the 3rd workshop on balloon-borne experiments with superconducting magnet spectrometers

    Yamamoto, Akira

    1992-04-01

    The Third Work Shop on Balloon Borne Experiment with a Superconducting Magnet Spectrometer was held at National Laboratory for High Energy Physics (KEK), Tsukuba, Japan on February 24 - 25, 1992. The main effort for this workshop was focused on the progress of the BESS (Balloon Borne Experiment with a Superconducting Spectrometer) experiment and on the scope for scientific investigation with the BESS detector. The progress was reviewed and further investigation was discussed for the BESS further scientific collaboration among Univ. of Tokyo, Kobe University, KEK, ISAS and NMSU. (J.P.N.)

  6. Universe of constant

    Yongquan, Han

    2016-10-01

    The ideal gas state equation is not applicable to ordinary gas, it should be applied to the Electromagnetic ``gas'' that is applied to the radiation, the radiation should be the ultimate state of matter changes or initial state, the universe is filled with radiation. That is, the ideal gas equation of state is suitable for the Singular point and the universe. Maybe someone consider that, there is no vessel can accommodate radiation, it is because the Ordinary container is too small to accommodate, if the radius of your container is the distance that Light through an hour, would you still think it can't accommodates radiation? Modern scientific determinate that the radius of the universe now is about 1027 m, assuming that the universe is a sphere whose volume is approximately: V = 4.19 × 1081 cubic meters, the temperature radiation of the universe (cosmic microwave background radiation temperature of the universe, should be the closest the average temperature of the universe) T = 3.15k, radiation pressure P = 5 × 10-6 N / m 2, according to the law of ideal gas state equation, PV / T = constant = 6 × 1075, the value of this constant is the universe, The singular point should also equal to the constant Author: hanyongquan

  7. Variable filter array spectrometer of VPD PbSe

    Linares-Herrero, R.; Vergara, G.; Gutiérrez-Álvarez, R.; Fernández-Montojo, C.; Gómez, L. J.; Villamayor, V.; Baldasano-Ramírez, A.; Montojo, M. T.

    2012-06-01

    MWIR spectroscopy shows a large potential in the current IR devices market, due to its multiple applications (gas detection, chemical analysis, industrial monitoring, combustion and flame characterization, food packaging etc) and its outstanding performance (good sensitivity, NDT method, velocity of response, among others), opening this technique to very diverse fields of application, such as industrial monitoring and control, agriculture, medicine and environmental monitoring. However, even though a big interest on MWIR spectroscopy technique has been present in the last years, two major barriers have held it back from its widespread use outside the laboratory: the complexity and delicateness of some popular techniques such as Fourier-transform IR (FT-IR) spectrometers, and the lack of affordable specific key elements such a MWIR light sources and low cost (real uncooled) detectors. Recent developments in electrooptical components are helping to overcome these drawbacks. The need for simpler solutions for analytical measurements has prompted the development of better and more affordable uncooled MWIR detectors, electronics and optics. In this paper a new MWIR spectrometry device is presented. Based on linear arrays of different geometries (64, 128 and 256 elements), NIT has developed a MWIR Variable Filter Array Spectrometer (VFAS). This compact device, with no moving parts, based on a rugged and affordable detector, is suitable to be used in applications which demand high sensitivity, good spectral discrimination, reliability and compactness, and where an alternative to the traditional scanning instrument is desired. Some measurements carried out for several industries will be also presented.

  8. Proton Transfer Time-of-Flight Mass Spectrometer

    Watson, Thomas B. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-01

    The Proton Transfer Reaction Mass Spectrometer (PTRMS) measures gas-phase compounds in ambient air and headspace samples before using chemical ionization to produce positively charged molecules, which are detected with a time-of-flight (TOF) mass spectrometer. This ionization method uses a gentle proton transfer reaction method between the molecule of interest and protonated water, or hydronium ion (H3O+), to produce limited fragmentation of the parent molecule. The ions produced are primarily positively charged with the mass of the parent ion, plus an additional proton. Ion concentration is determined by adding the number of ions counted at the molecular ion’s mass-to-charge ratio to the number of air molecules in the reaction chamber, which can be identified according to the pressure levels in the reaction chamber. The PTRMS allows many volatile organic compounds in ambient air to be detected at levels from 10–100 parts per trillion by volume (pptv). The response time is 1 to 10 seconds.

  9. Adaptive Tunable Laser Spectrometer for Space Applications

    Flesch, Gregory; Keymeulen, Didier

    2010-01-01

    An architecture and process for the rapid prototyping and subsequent development of an adaptive tunable laser absorption spectrometer (TLS) are described. Our digital hardware/firmware/software platform is both reconfigurable at design time as well as autonomously adaptive in real-time for both post-integration and post-launch situations. The design expands the range of viable target environments and enhances tunable laser spectrometer performance in extreme and even unpredictable environments. Through rapid prototyping with a commercial RTOS/FPGA platform, we have implemented a fully operational tunable laser spectrometer (using a highly sensitive second harmonic technique). With this prototype, we have demonstrated autonomous real-time adaptivity in the lab with simulated extreme environments.

  10. A compact multichannel spectrometer for Thomson scattering

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R. [Department of Engineering Physics, University of Wisconsin, Madison, Wisconsin 53706 (United States)

    2012-10-15

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T{sub e} < 100 eV are achieved by a 2971 l/mm VPH grating and measurements T{sub e} > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated ({approx}2 ns) ICCD camera for detection. A Gen III image intensifier provides {approx}45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  11. Partial pressure measurements with an active spectrometer

    Brooks, N.H.; Jensen, T.H.; Colchin, R.J.; Maingi, R.; Wade, M.R.; Finkenthal, D.F.; Naumenko, N.; Tugarinov, S.

    1998-07-01

    Partial pressure neutral ga measurements have been made using a commercial Penning gauge in conjunction with an active spectrometer. In prior work utilizing bandpass filters and conventional spectrometers, trace concentrations of the hydrogen isotopes H, D, T and of the noble gases He, Ne and Ar were determined from characteristic spectral lines in the light emitted by the neutral species of these elements. For all the elements mentioned, the sensitivity was limited by spectral contamination from a pervasive background of molecular hydrogen radiation. The active spectrometer overcomes this limitations by means of a digital lock-in method and correlation with reference spectra. Preliminary measurements of an admixture containing a trace amount of neon in deuterium show better than a factor of 20 improvement in sensitivity over conventional techniques. This can be further improved by correlating the relative intensities of multiple lines to sets of reference spectra

  12. Miniature neutron-alpha activation spectrometer

    Rhodes, Edgar; Goldsten, John; Holloway, James Paul; He, Zhong

    2002-01-01

    We are developing a miniature neutron-alpha activation spectrometer for in-situ analysis of chem-bio samples, including rocks, fines, ices, and drill cores, suitable for a lander or Rover platform for Mars or outer-planet missions. In the neutron-activation mode, penetrating analysis will be performed of the whole sample using a γ spectrometer and in the α-activation mode, the sample surface will be analyzed using Rutherford-backscatter and x-ray spectrometers. Novel in our approach is the development of a switchable radioactive neutron source and a small high-resolution γ detector. The detectors and electronics will benefit from remote unattended operation capabilities resulting from our NEAR XGRS heritage and recent development of a Ge γ detector for MESSENGER. Much of the technology used in this instrument can be adapted to portable or unattended terrestrial applications for detection of explosives, chemical toxins, nuclear weapons, and contraband

  13. A compact multichannel spectrometer for Thomson scatteringa)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R.

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of Te VPH grating and measurements Te > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated (˜2 ns) ICCD camera for detection. A Gen III image intensifier provides ˜45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  14. A compact multichannel spectrometer for Thomson scattering

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R.

    2012-01-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T e e > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated (∼2 ns) ICCD camera for detection. A Gen III image intensifier provides ∼45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  15. A compact multichannel spectrometer for Thomson scattering.

    Schoenbeck, N L; Schlossberg, D J; Dowd, A S; Fonck, R J; Winz, G R

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T(e) VPH grating and measurements T(e) > 100 eV by a 2072 l∕mm VPH grating. The spectrometer uses a fast-gated (~2 ns) ICCD camera for detection. A Gen III image intensifier provides ~45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  16. A high-resolution Fourier Transform Spectrometer for planetary spectroscopy

    Cruikshank, D. P.; Sinton, W. M.

    1973-01-01

    The employment of a high-resolution Fourier Transform Spectrometer (FTS) is described for planetary and other astronomical spectroscopy in conjunction with the 88-inch telescope at Mauna Kea Observatory. The FTS system is designed for a broad range of uses, including double-beam laboratory spectroscopy, infrared gas chromatography, and nuclear magnetic resonance spectroscopy. The data system is well-suited to astronomical applications because of its great speed in acquiring and transforming data, and because of the enormous storage capability of the magnetic tape unit supplied with the system. The basic instrument is outlined 2nd some of the initial results from the first attempted use on the Mauna Kea 88-inch telescope are reported.

  17. A VUV prism spectrometer for RICH radiator refractometry

    Moyssides, P G; Fokitis, E

    2000-01-01

    A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

  18. The ion mobility spectrometer for high explosive vapor detection

    Cohen, M.J.; Stimac, R.M.; Wernlund, R.F.

    1984-01-01

    The Phemto-Chem /SUP R/ Model 100 Ion Mobility Spectrometer (IMS) operates in air and measures a number of explosive vapors at levels as low as partsper-trillion in seconds. The theory and operation of this instrument is discussed. The IMS inhales the vapor sample in a current of air and generates characteristic ions which are separated by time-of -ion drift in the atmospheric pressure gas. Quantitative results, using a dilution tunnel and standard signal generator with TNT, nitroglycerine, ethylene glycol dinitrate, cyclohexanone, methylamine, octafluoronaphthalene and hexafluorobenzene, are given. Rapid sample treatment with sample concentrations, microprocessor signal readout and chemical identification, offer a realistic opportunity of rapid explosive vapor detection at levels down to 10 -14 parts by volume in air

  19. An off Axis Cavity Enhanced Absorption Spectrometer and a Rapid Scan Spectrometer with a Room-Temperature External Cavity Quantum Cascade Laser

    Liu, Xunchen; Kang, Cheolhwa; Xu, Yunjie

    2009-06-01

    Quantum cascade laser (QCL) is a new type of mid-infrared tunable diode lasers with superior output power and mode quality. Recent developments, such as room temperature operation, wide frequency tunability, and narrow line width, make QCLs an ideal light source for high resolution spectroscopy. Two slit jet infrared spectrometers, namely an off-axis cavity enhanced absorption (CEA) spectrometer and a rapid scan spectrometer with an astigmatic multi-pass cell assembly, have been coupled with a newly purchased room temperature tunable mod-hop-free QCL with a frequency coverage from 1592 cm^{-1} to 1698 cm^{-1} and a scan rate of 0.1 cm^{-1}/ms. Our aim is to utilize these two sensitive spectrometers, that are equipped with a molecular jet expansion, to investigate the chiral molecules-(water)_n clusters. To demonstrate the resolution and sensitivity achieved, the rovibrational transitions of the static N_2O gas and the bending rovibrational transitions of the Ar-water complex, a test system, at 1634 cm^{-1} have been measured. D. Hofstetter and J. Faist in High performance quantum cascade lasers and their applications, Vol.89 Springer-Verlag Berlin & Heidelberg, 2003, pp. 61-98. Y. Xu, X. Liu, Z. Su, R. M. Kulkarni, W. S. Tam, C. Kang, I. Leonov and L. D'Agostino, Proc. Spie, 2009, 722208 (1-11). M. J. Weida and D. J. Nesbitt, J. Chem. Phys. 1997, 106, 3078-3089.

  20. Indigenously built resonance ionization mass spectrometer

    Razvi, M.A.N.; Jayasekharan, T.; Thankarajan, K.; Guhagarkar, M.B.; Dixit, M.N.; Bhale, G.L.

    2000-04-01

    Design, fabrication and performance testing of an indigenously built Resonance Ionization Mass Spectrometer (RIMS) is presented in this report. The instrument is totally indigenous, but for the laser components consisting of the excimer laser and tunable dye lasers. Constructional details of atomic beam source and linear time-of-flight mass spectrometer are included. Finally, commissioning and performance testing of the instrument is described. Mass resolving power of 400 and a detection limit of 100 atoms has been achieved using this RIMS set-up. (author)

  1. Upgrade of an old Raman Spectrometer

    Hansen, Susanne Brunsgaard; Berg, Rolf W.; Stenby, Erling Halfdan

    2004-01-01

    Improvement of a conventional Jeol Raman spectrometer with a single channel photo multiplier detector is described. New optical components (fibres, mirror, lens and CCD detector) have been chosen to design a high quality and easy-to-use instrument. Tests have shown that with this modified...... spectrometer Raman spectra can be acquired of a quality comparable to the spectra obtained previously, but the time needed to obtain a spectrum is markedly reduced. Selected test spectra and a simple calibration procedure to obtain the wavenumber values from the band CCD pixel position are presented....

  2. A proposed neutron spectrometer system for JET

    Elevant, T.; Hellbom, G.; Scheffel, J.; Malmskog, S.

    1979-12-01

    A neutron spectrometer system is proposed primarily for measurements of ion temperature and density and ion beam energy distribution in extended fusion plasmas like e.g. in JET. Three different spectrometers are involved: time of flight, proton recoil and 3 He. Energy resolutions of a few percent both for DD and DT neutrons are provided. Six order of magnitudes in flux ranges will be covered by the system when employing multi-target systems. A neutron collimator and shielding system will be desirable in order to obtain relevant information. Due to the entire differences in energy and fluxes for DD and DT plasmas a flexible collimator-shielding system is recommended

  3. Beam analysis spectrometer for relativistic heavy ions

    Schimmerling, W.; Subramanian, T.S.; McDonald, W.J.; Kaplan, S.N.; Sadoff, A.; Gabor, G.

    1983-01-01

    A versatile spectrometer useful for measuring the mass, charge, energy, fluence and angular distribution of primaries and fragments associated with relativistic heavy ion beams is described. The apparatus is designed to provide accurate physical data for biology experiments and medical therapy planning as a function of depth in tissue. The spectrometer can also be used to measure W, the average energy to produce an ion pair, range-energy, dE/dx, and removal cross section data of interest in nuclear physics. (orig.)

  4. Single spectrometer station for neutrino-tagging

    Nedyalkov, I.P.

    1984-01-01

    A neutrino tagging station built with respect to the following scheme is proposed. A beam of muons and kaons passes through a magnetic spectrometer, where the energy of each particle is measured. There are coordinate detectors behind the spectrometer in several planes, where the direction of the trajectory of a given particle is determined. Thus, mesons enter the decay point wth the known 4-momentum. Behind the decay point the direction of μ-meson generated by the decay of parent mesons is measured. It is shown that information is sufficient for determining the kind of parent particle (pion or kaon), the energy and the direction of trajectory of the neutrino

  5. Spectrometer Baseline Control Via Spatial Filtering

    Burleigh, M. R.; Richey, C. R.; Rinehart, S. A.; Quijada, M. A.; Wollack, E. J.

    2016-01-01

    An absorptive half-moon aperture mask is experimentally explored as a broad-bandwidth means of eliminating spurious spectral features arising from reprocessed radiation in an infrared Fourier transform spectrometer. In the presence of the spatial filter, an order of magnitude improvement in the fidelity of the spectrometer baseline is observed. The method is readily accommodated within the context of commonly employed instrument configurations and leads to a factor of two reduction in optical throughput. A detailed discussion of the underlying mechanism and limitations of the method are provided.

  6. Ion transmission in a linear radiofrequency spectrometer

    Gomet, J.-C.

    1975-01-01

    A linear radiofrequency spectrometer is used for the purpose of experimental determination of the absolute ionization cross sections of various ions obtained by electron impact on polyatomic molecules. The transmission of the apparatus is studied: it does not only depend on the mass resolution of the spectrometer, but also on the nature of ions. It is affected by charge transfers, especially for the parent ions. An empiric way of correction of the apparatus function is given which allows the use at 10 -6 Torr [fr

  7. Noise considerations in millimeter-wave spectrometers

    Zoellner, W.D.; Kolbe, W.F.; Leskovar, B.

    1978-12-01

    An improved version of a microwave spectrometer operating in the vicinity of 70 GHz is described. The spectrometer, which incorporates a Fabry-Perot resonator and superheterodyne detection for high sensitivity is designed for the detection of gaseous pollutants and other atmospheric constituents. The instrument is capable of detecting polar molecules with absorption coefficients as small as 2 x 10 -9 cm -1 . For sulphur dioxide diluted in air, this sensitivity corresponds to a detection limit of 1.2 ppm without preconcentration and with a time constant of 1 second. Measurements and analysis of the noise contributions limiting the sentivity are presented

  8. A driving system for Moessbauer spectrometer

    Maslan, M.; Cholmeckij, A.; Evdokimov, V.; Misevic, O.; Fedorov, A.; Zak, D.

    1993-01-01

    The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 ± 0.01 mm/s. (author). 6 figs., 8 refs

  9. Large acceptance spectrometers for π0 mesons

    Awes, T.C.; Ferguson, R.L.; Obenshain, F.E.

    1984-01-01

    A spectrometer composed of lead-oxide loaded glass blocks has been constructed for detection of neutral pi mesons emitted in low energy heavy ion reactions. The spectrometer detects the Cerenkov radiation emitted when the high energy photons (Eγ approx. 70 MeV) resulting from π 0 decay create electron-position pairs in the glass, initiating electromagnetic showers. A geometric acceptance of better than 5% of 4π is possible; the π 0 detection efficiency varies between this value at T/sub π/ = 0 MeV and 1% for T/sub π/ approx. 100 MeV

  10. Streaked, x-ray-transmission-grating spectrometer

    Ceglio, N.M.; Roth, M.; Hawryluk, A.M.

    1981-08-01

    A free standing x-ray transmission grating has been coupled with a soft x-ray streak camera to produce a time resolved x-ray spectrometer. The instrument has a temporal resolution of approx. 20 psec, is capable of covering a broad spectral range, 2 to 120 A, has high sensitivity, and is simple to use requiring no complex alignment procedure. In recent laser fusion experiments the spectrometer successfully recorded time resolved spectra over the range 10 to 120 A with a spectral resolving power, lambda/Δlambda of 4 to 50, limited primarily by source size and collimation effects

  11. Scientific Payload Of The Emirates Mars Mission: Emirates Mars Infrared Spectrometer (Emirs) Overview.

    Altunaiji, E. S.; Edwards, C. S.; Christensen, P. R.; Smith, M. D.; Badri, K. M., Sr.

    2017-12-01

    The Emirates Mars Mission (EMM) will launch in 2020 to explore the dynamics in the atmosphere of Mars on a global scale. EMM has three scientific instruments to an improved understanding of circulation and weather in the Martian lower and middle atmosphere. Two of the EMM's instruments, which are the Emirates eXploration Imager (EXI) and Emirates Mars Infrared Spectrometer (EMIRS) will focus on the lower atmosphere observing dust, ice clouds, water vapor and ozone. On the other hand, the third instrument Emirates Mars Ultraviolet Spectrometer (EMUS) will focus on both the thermosphere of the planet and its exosphere. The EMIRS instrument, shown in Figure 1, is an interferometric thermal infrared spectrometer that is jointly developed by Arizona State University (ASU) and Mohammed Bin Rashid Space Centre (MBRSC). It builds on a long heritage of thermal infrared spectrometers designed, built, and managed, by ASU's Mars Space Flight Facility, including the Thermal Emission Spectrometer (TES), Miniature Thermal Emission Spectrometer (Mini-TES), and the OSIRIS-REx Thermal Emission Spectrometer (OTES). EMIRS operates in the 6-40+ µm range with 5 cm-1 spectral sampling, enabled by a Chemical Vapor-Deposited (CVD) diamond beamsplitter and state of the art electronics. This instrument utilizes a 3×3 detector array and a scan mirror to make high-precision infrared radiance measurements over most of a Martian hemisphere. The EMIRS instrument is optimized to capture the integrated, lower-middle atmosphere dynamics over a Martian hemisphere and will capture 60 global images per week ( 20 images per orbit) at a resolution of 100-300 km/pixel. After processing through an atmospheric retrieval algorithm, EMIRS will determine the vertical temperature profiles to 50km altitude and measure the column integrated global distribution and abundances of key atmospheric parameters (e.g. dust, water ice (clouds) and water vapor) over the Martian day, seasons and year.

  12. Early Design Stage of the MsAa-4 Moessbauer Spectrometer

    Blachowski, A.; Ruebenbauer, K.; Zukrowski, J.; Gornicki, R.

    2008-01-01

    Entirely new Moessbauer spectrometer MsAa-4 is currently under design and construction. New features as compared to the basic features of the previous generation MsAa-3 spectrometer could be summarized as follows. Completely digital processing of the γ-ray detector signal beyond the Gaussian shape filter/amplifier is to be implemented. The spectrometer is going to be able to accommodate external multiple detector heads. One could collect simultaneously up to 128 γ-ray spectra in 16384 channels of 32-bit each and up to 512 Moessbauer spectra in 4096 channels of 32-bit each provided the proper external multiple detector head is used. The count-rate per single detector is limited to about 105 counts per second total. Improved precision of the reference function from 12-bit to 16-bit is to be provided. The reference function is stored in 8192 channels per complete cycle. Addition of the random noise to the reference corner prism of the Michelson-Morley calibration interferometer is to be introduced to avoid spurious fringes due to the phase lock-up. Integrated universal temperature controller being able to use variety of the temperature sensors is to be interconnected with the proper spectrometer. The spectrometer is now a stand-alone network device as it is equipped with the Ethernet connection to the outside world. Modular design and use of the strict standards allows easy reconfiguration for other applications than the Moessbauer spectroscopy. (authors)

  13. The OVIRS Visible/IR Spectrometer on the OSIRIS-Rex Mission

    Reuter, D. C.; Simon-Miller, A. A.

    2012-01-01

    The OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security Regolith Explorer) Mission is a planetary science mission to study, and return a sample from, the carbonaceous asteroid 1999 RQ-36. The third mission selected under NASA's New Frontiers Program, it is scheduled to be launched in 2016. It is led by PI Dante Lauretta at the University of Arizona and managed by NASA's Goddard Space Flight Center. The spacecraft and the asteroid sampling mechanism, TAGSAM (Touch-And-Go Sample Acquisition Mechanism) will be provided by Lockheed Martin Space Systems. Instrumentation for studying the asteroid include: OCAMS (the OSIRIS-REx Camera Suite), OLA (the OSIRIS-REx Laser Altimeter, a scanning LIDAR), OTES (The OSIRIS-REx Thermal Emission Spectrometer, a 4-50 micron point spectrometer) and OVIRS (the OSIRIS-REx Visible and IR Spectrometer, a 0.4 to 4.3 micron point spectrometer). The payload also includes REXIS (the Regolith X-ray Imaging Spectrometer) a student provided experiment. This paper presents a description of the OVIRS instrument.

  14. Equipment and performance of the Q3D spectrometer installed at the tandem laboratory of Saclay

    Berthier, B.

    1979-01-01

    A quadrupole - dipole - dipole - dipole (Q3D) magnetic spectrometer with proportional gas counter which has been installed at the tandem laboratory of Saclay is described. Typical results are given indicating the performance of the apparatus in studies of heavy ion reactions at tandem energies for which good energy resolution and large solid angles are required. Improvements to allow the detection of heavier masses and less energetic ions with better energy resolution are planned. (U.K.)

  15. Triple-axis spectrometer DruechaL

    Buehrer, W.; Keller, P.

    1996-01-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs

  16. Neutron spectrometer using NE218 liquid scintillator

    Dance, J.B.; Francois, P.E.

    1976-01-01

    A neutron spectrometer has been constructed using NE218 liquid scintillator. Discrimination against electron-gamma events was obtained usng a charge-comparison pulse shape discrimination system. The resolution obtained was about 0.25 MeV F.W.H.M. at 2.0 MeV

  17. A 4-PI DILEPTON SPECTROMETER - PEPSI

    BUDA, A; BACELAR, JCS; BALANDA, A; VANKLINKEN, J; SUJKOWSKI, Z; VANDERWOUDE, A

    1993-01-01

    A novel positron-electron pair spectroscopy instrument (PEPSI) was designed to measure transitions in the energy region 10-40 MeV. It consists of Nd2Fe14B permanent magnets forming a compact 4 pi magnetic filter consisting of 12 positron and 20 electron mini-orange-like spectrometers. The response

  18. Calculational approach to ionization spectrometer design

    Gabriel, T.A.

    1974-01-01

    Many factors contribute to the design and overall performance of an ionization spectrometer. These factors include the conditions under which the spectrometer is to be used, the required performance, the development of the hadronic and electromagnetic cascades, leakage and binding energies, saturation effects of densely ionizing particles, nonuniform light collection, sampling fluctuations, etc. The calculational procedures developed at Oak Ridge National Laboratory that have been applied to many spectrometer designs and that include many of the influencing factors in spectrometer design are discussed. The incident-particle types which can be considered with some generality are protons, neutrons, pions, muons, electrons, positrons, and gamma rays. Charged kaons can also be considered but with less generality. The incident-particle energy range can extend into the hundreds of GeV range. The calculations have been verified by comparison with experimental data but only up to approximately 30 GeV. Some comparisons with experimental data are also discussed and presented so that the flexibility of the calculational methods can be demonstrated. (U.S.)

  19. A 'tiny-orange' spectrometer for electrons

    Silva, N.C. da.

    1990-01-01

    An tiny-orange electron spectrometer was designed and constructed using flat permanent magnets and a surface barrier detector. The transmission functions of different system configurations were determined for energies in the 200-1100 KeV range. A mathematical model for the system was developed. (L.C.J.A.)

  20. Triple-axis spectrometer DruechaL

    Buehrer, W; Keller, P [Lab. for Neutron Scattering ETH Zurich, Zurich (Switzerland) and Paul Scherrer Institute, Villigen (Switzerland)

    1996-11-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs.

  1. COMPASS course to future computing [CERN spectrometer

    CERN. Geneva

    1999-01-01

    A major new spectrometer that is being installed at CERN will be a flagship fixed-target experiment for the millennium. Its voracious appetite for data requires new computing solutions, opening the door for subsequent 2lst-century studies. (0 refs).

  2. Calibration method for ion mobility spectrometer

    Vasiliev, Valery

    2011-01-01

    The new method for the calibration of the ion mobility spectrometer has been developed. This article describes the working principle, advantages and disadvantages of the calibration method operating in the mode of explosives detection. This method is most suitable for use in portable detectors, due to the small weight, small size parameters and low power consumption.

  3. A superheterodyne spectrometer for electronic paramagnetic. Resonance

    Laffon, J.L.

    1963-12-01

    After a few generalities about electron paramagnetic resonance, a consideration of different experimental techniques authorises the choice of a particular type of apparatus. An EPR superheterodyne spectrometer built in the laboratory and having a novel circuit is described in detail. With this apparatus, many experimental results have been obtained and some of these are described as example. (author) [fr

  4. String Gas Cosmology

    Brandenberger, Robert H.

    2008-01-01

    String gas cosmology is a string theory-based approach to early universe cosmology which is based on making use of robust features of string theory such as the existence of new states and new symmetries. A first goal of string gas cosmology is to understand how string theory can effect the earliest moments of cosmology before the effective field theory approach which underlies standard and inflationary cosmology becomes valid. String gas cosmology may also provide an alternative to the curren...

  5. OLYMPEX Counterflow Spectrometer and Impactor Field Campaign Report

    Poellot, Michael [Univ. of North Dakota, Grand Forks, ND (United States)

    2016-07-01

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s ARM Aerial Facility (AAF) Counterflow Spectrometer and Impactor (CSI) probe was flown on the University of North Dakota Cessna Citation research aircraft during the Olympic Mountain Experiment (OLYMPEX). The field campaign took place from November 12 through December 19, 2015, over the Olympic Mountains and coastal waters of Washington State as part of a National Aeronautics and Space Administration (NASA) Global Precipitation Measurement (GPM) validation campaign. The CSI was added to the Citation instrument suite to support the NASA Aerosol-Cloud Ecosystem (ACE) satellite program and flights of the NASA Lockheed Earth Resources (ER-2) aircraft. ACE funded extra ER-2 flights to focus on clouds that are weakly precipitating, which are also of interest to the DOE Atmospheric System Research (ASR) program.

  6. Capillary absorption spectrometer and process for isotopic analysis of small samples

    Alexander, M. Lizabeth; Kelly, James F.; Sams, Robert L.; Moran, James J.; Newburn, Matthew K.; Blake, Thomas A.

    2018-04-24

    A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The process also permits sampling in vivo permitting real-time ambient studies of microbial communities.

  7. Capillary absorption spectrometer and process for isotopic analysis of small samples

    Alexander, M. Lizabeth; Kelly, James F.; Sams, Robert L.; Moran, James J.; Newburn, Matthew K.; Blake, Thomas A.

    2016-03-29

    A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The method also permits sampling in vivo permitting real-time ambient studies of microbial communities.

  8. Studies on reducing the scale of a double focusing mass spectrometer

    Chambers, D.M.; Gregg, H.R.; Andresen, B.D.

    1993-05-01

    Several groups have developed miniaturized sector mass spectrometers with the goal of remote sensing in confined spaces or portability. However, these achievements have been overshadowed by more successful development of man-portable quadrupole and ion trap mass spectrometers. Despite these accomplishments the development of a reduced-scale sector mass spectrometer remains attractive as a potentially low-cost, robust instrument requiring very simple electronics and low power. Previous studies on miniaturizing sector instruments include the use of a Mattauch-Herzog design for a portable mass spectrograph weighing less than 10 kg. Other work has included the use of a Nier-Johnson design in spacecraft-mountable gas chromatography mass spectrometers for the Viking spacecraft as well as miniature sector-based MS/MS instrument. Although theory for designing an optimized system with high resolution and mass accuracy is well understood, such specifications have not yet been achieved in a miniaturized instrument. To proceed further toward the development of a miniaturized sector mass spectrometer, experiments were conducted to understand and optimize a practical, yet nonideal instrument configuration. The sector mass spectrometer studied in this work is similar to the ones developed for the Viking project, but was further modified to be low cost, simple and robust. Characteristics of this instrument that highlight its simplicity include the use of a modified Varian leak detector ion source, source ion optics that use one extraction voltage, and an unshunted fixed nonhomogeneous magnetic sector. The effects of these design simplifications on ion trajectory were studied by manipulating the ion beam along with the magnetic sector position. This latter feature served as an aid to study ion focusing amidst fringing fields as well as nonhomogeneous forces and permitted empirical realignment of the instrument

  9. Novel Miniature Spectrometer For Remote Chemical Detection

    Pipino, Andrew C.R.

    2000-01-01

    New chemical sensing technologies are critically important for addressing many of EM's priority needs as discussed in detail at http://emsp.em.doe.gov/needs. Many technology needs were addressed by this research. For example, improved detection strategies are needed for non-aqueous phase liquids (NAPL's), such as PCE (Cl2C=CCl2) and TCE (HClC=CCl2), which persist in the environment due their highly stable structures. By developing a miniature, ultra-sensitive, selective, and field-deployable detector for NAPL's, the approximate source location could be determined with minimal investigative expense. Contaminant plumes could also be characterized in detail. The miniature spectrometer developed under Project No.60231 could also permit accurate rate measurements in less time, either in the field or the laboratory, which are critically important in the development, testing, and ultimate utilization of models for describing contaminant transport. The technology could also be used for long-term groundwater monitoring or long-term stewardship in general. Many science needs are also addressed by the Project 60231, since the effort significantly advances the measurement science of chemical detection. Developed under Project No.60231, evanescent wave cavity ring-down spectroscopy (EW-CRDS) is a novel form of CRDS, which is an the emerging optical absorption technique. Several review articles on CRDS, which has been generally applied only to gas-phase diagnostics, have been published1-3. EW-CRDS4-10 forms the basis for a new class of chemical sensors that extends CRDS to other states of matter and leads to a miniaturized version of the concept. EW-CRDS uses miniature solid-state optical resonators that incorporate one or more total internal reflection (TIR) surfaces, which create evanescent waves. The evanescent waves emanate from the TIR surfaces, sampling the surrounding medium. The utility of evanescent waves in chemical analysis forms the basis for the field of attenuated

  10. Greenhouse gas (GHG) emission in organic farming. Approximate quantification of its generation at the organic garden of the School of Agricultural, Food and Biosystems Engineering (ETSIAAB) in the Technical University of Madrid (UPM)

    Campos, Jorge; Barbado, Elena; Maldonado, Mariano; Andreu, Gemma; López de Fuentes, Pilar

    2016-04-01

    As it well-known, agricultural soil fertilization increases the rate of greenhouse gas (GHG) emission production such as CO2, CH4 and N2O. Participation share of this activity on the climate change is currently under study, as well as the mitigation possibilities. In this context, we considered that it would be interesting to know how this share is in the case of organic farming. In relation to this, a field experiment was carried out at the organic garden of the School of Agricultural, Food and Biosystems Engineering (ETSIAAB) in the Technical University of Madrid (UPM). The orchard included different management growing areas, corresponding to different schools of organic farming. Soil and gas samples were taken from these different sites. Gas samples were collected throughout the growing season from an accumulated atmosphere inside static chambers inserted into the soil. Then, these samples were carried to the laboratory and there analyzed. The results obtained allow knowing approximately how ecological fertilization contributes to air pollution due to greenhouse gases.

  11. The portable micro-computerized multichannel spectrometer for geological application

    Fang Fang; Jia Wenyi; Zou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which is consisted of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for filed geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  12. The portable micro-computerized multichannel spectrometer for geological application

    Fang Fang; Jia Wenyi; Zhou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which consists of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for field geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  13. High resolution solar soft X-ray spectrometer

    Zhang Fei; Wang Huanyu; Peng Wenxi; Liang Xiaohua; Zhang Chunlei; Cao Xuelei; Jiang Weichun; Zhang Jiayu; Cui Xingzhu

    2012-01-01

    A high resolution solar soft X-ray spectrometer (SOX) payload onboard a satellite is developed. A silicon drift detector (SDD) is adopted as the detector of the SOX spectrometer. The spectrometer consists of the detectors and their readout electronics, a data acquisition unit and a payload data handling unit. A ground test system is also developed to test SOX. The test results show that the design goals of the spectrometer system have been achieved. (authors)

  14. RADIO-FREQUENCY MASS SPECTROMETERS AND THEIR APPLICATIONS IN SPACE

    Gilmour, Jr., A. S.

    1963-08-15

    The operation of three common radio-frequency mass spectrometers is described, and their performances are compared. Their limitations are pointed out. It is concluded that the quadrupole spectrometer has fewer limitations and is more generally useful in space probes than the other devices. Some present and proposed uses of spectrometers in space are discussed, and the problem of contamination of the atmosphere being sampled by the spectrometer is reviewed. (auth)

  15. A magnetic-lens - mini-orange coincidence spectrometer

    Bargholtz, C.; Holmberg, L.; Ruus, N.; Tegner, P.E.; Weiss, G.

    1997-04-01

    A coincidence spectrometer consisting of a Gerholm type magnetic lens and a permanent magnet mini-orange spectrometer is described. Electron-electron or electron-positron coincidences may be registered in various angular settings. The spectrometer has been developed mainly to search for anomalous contributions to Bhabha scattering or positrons and is at present used for such studies. 6 refs

  16. Spectrometer for neutron inelastic scattering investigations of microsamples

    Balagurov, A.M.; Kozlenko, D.P.; Platonov, S.L.; Savenko, B.N.; Glazkov, V.P.; Krasnikov, Yu.M.; Naumov, I.V.; Pukhov, A.V.; Somenkov, V.A.; Syrykh, G.F.

    1997-01-01

    A new neutron spectrometer for investigation of inelastic neutron scattering on polycrystal microsamples under high pressure in sapphire and diamond anvils cells is described. The spectrometer is operating at the IBR-2 pulsed reactor in JINR. Parameters and methodical peculiarities of the spectrometer and the examples of experimental studies are given. (author)

  17. Microorganisms are making large progress. DaimlerChrysler supports biotechnology research at universities; Mikroorganismen geben Gas. DaimlerChrysler unterstuetzt Biotechnologieforschung an Hochschulen

    Anon.

    2003-07-01

    In order to improve the cooperation between economy and science the DaimlerChrysler Challenge Fund sponsors research at American universities. Some projects deal with hydrogen that is generated biologically and supposed to be stored in new tanks. (orig.) [German] Um die Kooperation zwischen Wirtschaft und Wissenschaft zu verbessern, sponsert der DaimlerChrysler Challenge Fund die Forschung an nordamerikanischen Hochschulen. Einige Projekte befassen sich mit Wasserstoff, der biologisch erzeugt und in neuartigen Tanks gespeichert werden soll. (orig.)

  18. Mass spectrometer introduction line: application to the analysis of impurities in uranium hexafluoride

    Besson, M.

    1967-01-01

    The continuous mass-spectrometric analysis of impurities in UF 6 is possible industrially if certain conditions imposed by the nature of the gas are respected. The gas introduction line arriving at the spectrometer's source makes it possible to fix the flow-rate, to control the inlet pressure and to selectively destroy the gas containing the impurities. The operational conditions for the line are defined and a description is given of the theoretical and experimental study of the various elements of which it is composed, i.e. the leak valve, the flow-meter, the chemical trap and the servo-mechanism making it possible to regulate and control the gas flow. The dynamic characteristics of the line's various components and the performance of the equipment in the case of the analyses considered are given. (author) [fr

  19. Feasibility studies for the Forward Spectrometer

    Biernat, Jacek

    2015-01-01

    The Forward Spectrometer designed for the P-barANDA detector will consist of many different detector systems allowing for precise track reconstruction and particle identification. Feasibility studies for Forward Spectrometer done by means of specific reactions will be presented. In the first part of the paper, results of simulations focussing on rate estimates of the tracking stations based on straw tubes will be presented. Next, the importance of the Forward Tracker will be demonstrated through the reconstruction of the ψ(4040) → DD-bar decay. Finally, results from the analysis of the experimental data collected with a straw tube prototype designed and constructed at the Research Center in Juelich will be discussed. (paper)

  20. Sample changer for X-ray spectrometer

    Kaestner, F.; Bisch, H.

    1977-01-01

    A sample planchette with several samples in a spectrometer is rotated so as to position each sample in succession in a counting position. To change the planchette, the cover of the spectrometer raises together with the planchette and rotates to the side into a vertical magazine. The planchette is unhooked onto a tray which rapidly moves to a position above the cover, and the next planchette in the magazine stack moves upwards on a tray and is hooked to the cover and taken to the counting station. Three chains ensure the movement of the planchette trays in the magazine, one for raising the uncounted samples up the magazine, one for shifting the counted ones to the upper stack, and one to move the counted planchettes higher up the magazine. The movement of the chains is controlled by microswitches. (ORU) [de

  1. A 4π dilepton spectrometer: PEPSI

    Buda, A.; Bacelar, J.C.S.; Balanda, A.; Klinken, J. van; Sujkowski, Z.; Woude, A. van der

    1993-01-01

    A novel positron-electron pair spectroscopy instrument (PEPSI) was designed to measure transitions in the energy region 10-40 MeV. It consists of Nd 2 Fe 14 B permanent magnets forming a compact 4π magnetic filter consisting of 12 positron and 20 electron mini-orange-like spectrometers. The response function of PEPSI has been measured with mono-energetic beams of electrons from 5 to 20 MeV. The PEPSI spectrometer was used for measuring the internal pair conversion coefficient (α π ) of the 15.1 MeV M1 transition from a J π =1 + state to the ground state in 12 C. Our experimental value of α π =(3.3±0.5)x10 -3 is in good agreement with theoretical estimates. (orig.)

  2. A 4 π dilepton spectrometer: PEPSI

    Buda, A.; Bacelar, J. C. S.; Bałanda, A.; van Klinken, J.; Sujkowski, Z.; van der Woude, A.

    1993-11-01

    A novel positron-electron pair spectroscopy instrument (PEPSI) was designed to measure transitions in the energy region 10-40 MeV. It consists of Nd 2Fe 14B permanent magnets forming a compact 4 π magnetic filter consisting of 12 positron and 20 electron mini-orange-like spectrometers. The response function of PEPSI has been measured with mono-energetic beams of electrons from 5 to 20 MeV. The PEPSI spectrometer was used for measuring the internal pair conversion coefficient ( απ) of the 15.1 MeV M1 transition from a Jπ = 1 + state to the ground state in 12C. Our experimental value of απ = (3.3 ± 0.5) × 10 -3 is in good agreement with theoretical estimates.

  3. Inelastic rotor spectrometer at the Harwell Linac

    Boland, B.C.

    1983-01-01

    The spectrometer is designed to measure energy transfer from 50 MeV to 400 MeV covering a range of Q values from 1 to 15 A - 1 . Particular emphasis has been placed on the low Q counter banks where measurements at low Q reduce multiphonon contributions in vibrational spectra, diffusional broadening in liquids and allow measurements to be made on magnetic excitations. All indications are that the energy resolution is as predicted and is certainly twice as good as that of any other spectrometer presently available to the UK users at these energy transfers. Backgrounds on the high angle banks 24 0 to 94 0 are excellent but at the low angles are too high at present for anything but hydrogenous samples. Tests have shown that much of this background comes from the main beam in the area of the collimation between the chopper and the sample, and steps are being taken to improve this area

  4. The Harwell back-scattering spectrometer

    Windsor, C.G.; Bunce, L.J.; Borcherds, P.H.; Cole, I.; Fitzmaurice, M.; Johnson, D.A.G.; Sinclair, R.N.

    1976-01-01

    Neutron diffraction spectra in which both high resolution (Δ Q/Q approximately equal to 0.003) and high intensity are maintained up to scattering vectors as high as 30A -1 (sin theta/lambda = 2.5) have been obtained with the back-scattering spectrometer (BSS) recently installed on the Harwell electron linac. The theory behind the spectrometer design is described, and it is shown how the above resolution requirement leads to its basic features of a 12m incident flight path, a 2m scattering flight path and a scattering angle (2theta) acceptance from 165 0 to 175 0 . Examples of the resolution, intensity and background are given. It is shown that the problem of frame overlap may be overcome by using an absorbing filter. (author)

  5. Alignment of the ATLAS central muon spectrometer

    Chevallier, F

    2008-01-01

    The muon spectrometer of the ATLAS experiment is one of the largest detectors ever built. At the LHC, new physics signs could appear through high momenta muons (1 TeV). Identification and precise momentum measurement of such muons are two of the main challenges of the ATLAS muon spectrometer. In order to get a good resolution for high energy muons (i.e. 10% at 1 TeV), the accuracy on the alignment of precision chambers must be of the order of 50 microns. Several procedures have been developed to reach such a precision. This document describes complementary techniques used to align the muon sub-detectors, and their results : the optical system, the muon cosmic rays and the straight tracks coming from collisions.

  6. The SeaQuest Spectrometer at Fermilab

    Aidala, C.A.; et al.

    2017-06-29

    The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

  7. Neutron spectrometer for improved SNM search.

    Vance, Andrew L.; Aigeldinger, Georg

    2007-03-01

    With the exception of large laboratory devices with very low sensitivities, a neutron spectrometer have not been built for fission neutrons such as those emitted by special nuclear materials (SNM). The goal of this work was to use a technique known as Capture Gated Neutron Spectrometry to develop a solid-state device with this functionality. This required modifications to trans-stilbene, a known solid-state scintillator. To provide a neutron capture signal we added lithium to this material. This unique triggering signal allowed identification of neutrons that lose all of their energy in the detector, eliminating uncertainties that arise due to partial energy depositions. We successfully implemented a capture gated neutron spectrometer and were able to distinguish an SNM like fission spectrum from a spectrum stemming from a benign neutron source.

  8. Solar maximum ultraviolet spectrometer and polarimeter

    Tandberg-Hanssen, E.; Woodgate, B. E.; Brandt, J. C.; Chapman, R. D.; Hyder, C. L.; Michalitsianos, A. G.; Shine, R. A.; Athay, R. G.; Beckers, J. M.; Bruner, E. C.

    1979-01-01

    The objectives of the UVSP experiment are to study solar ultraviolet radiations, particularly from flares and active regions, and to measure constituents in the terrestrial atmosphere by the extinction of sunlight at satellite dawn and dusk. The instrument is designed to observe the Sun at a variety of spectral and spatial resolutions in the range from 1150 to 3600 A. A Gregorian telescope with effective focal length of 1.8 m is used to feed a 1 m Ebert-Fastie spectrometer. A polarimeter containing rotatable magnesium fluoride waveplates is included behind the spectrometer entrance slit and will allow all four Stokes parameters to be determined. Velocities on the Sun can also be measured. The instrument is controlled by a computer which can interact with the data stream to modify the observing program. The observing modes, including rasters, spectral scans, velocity measurements, and polarimetry, are also described along with plans for mission operations, data handling, and analysis of the observations.

  9. The transition-edge EBIT microcalorimeter spectrometer

    Betancourt-Martinez, Gabriele L.; Adams, Joseph; Bandler, Simon; Beiersdorfer, Peter; Brown, Gregory; Chervenak, James; Doriese, Randy; Eckart, Megan; Irwin, Kent; Kelley, Richard; Kilbourne, Caroline; Leutenegger, Maurice; Porter, F. S.; Reintsema, Carl; Smith, Stephen; Ullom, Joel

    2014-07-01

    The Transition-edge EBIT Microcalorimeter Spectrometer (TEMS) is a 1000-pixel array instrument to be delivered to the Electron Beam Ion Trap (EBIT) facility at the Lawrence Livermore National Laboratory (LLNL) in 2015. It will be the first fully operational array of its kind. The TEMS will utilize the unique capabilities of the EBIT to verify and benchmark atomic theory that is critical for the analysis of high-resolution data from microcalorimeter spectrometers aboard the next generation of x-ray observatories. We present spectra from the present instrumentation at EBIT, as well as our latest results with time-division multiplexing using the current iteration of the TEMS focal plane assembly in our test platform at NASA/GSFC.

  10. Galaxy And Mass Assembly (GAMA): Gas Fueling of Spiral Galaxies in the Local Universe. I. The Effect of the Group Environment on Star Formation in Spiral Galaxies

    Grootes, M. W.; Tuffs, R. J.; Popescu, C. C.; Norberg, P.; Robotham, A. S. G.; Liske, J.; Andrae, E.; Baldry, I. K.; Gunawardhana, M.; Kelvin, L. S.; Madore, B. F.; Seibert, M.; Taylor, E. N.; Alpaslan, M.; Brown, M. J. I.; Cluver, M. E.; Driver, S. P.; Bland-Hawthorn, J.; Holwerda, B. W.; Hopkins, A. M.; Lopez-Sanchez, A. R.; Loveday, J.; Rushton, M.

    2017-03-01

    We quantify the effect of the galaxy group environment (for group masses of 1012.5-1014.0 M ⊙) on the current star formation rate (SFR) of a pure, morphologically selected sample of disk-dominated (I.e., late-type spiral) galaxies with redshift ≤0.13. The sample embraces a full representation of quiescent and star-forming disks with stellar mass M * ≥ 109.5 M ⊙. We focus on the effects on SFR of interactions between grouped galaxies and the putative intrahalo medium (IHM) of their host group dark matter halos, isolating these effects from those induced through galaxy-galaxy interactions, and utilizing a radiation transfer analysis to remove the inclination dependence of derived SFRs. The dependence of SFR on M * is controlled for by measuring offsets Δlog(ψ *) of grouped galaxies about a single power-law relation in specific SFR, {\\psi }* \\propto {M}* -0.45+/- 0.01, exhibited by non-grouped “field” galaxies in the sample. While a small minority of the group satellites are strongly quenched, the group centrals and a large majority of satellites exhibit levels of ψ * statistically indistinguishable from their field counterparts, for all M *, albeit with a higher scatter of 0.44 dex about the field reference relation (versus 0.27 dex for the field). Modeling the distributions in Δlog(ψ *), we find that (I) after infall into groups, disk-dominated galaxies continue to be characterized by a similar rapid cycling of gas into and out of their interstellar medium shown prior to infall, with inflows and outflows of ˜1.5-5 x SFR and ˜1-4 x SFR, respectively; and (II) the independence of the continuity of these gas flow cycles on M * appears inconsistent with the required fueling being sourced from gas in the circumgalactic medium on scales of ˜100 kpc. Instead, our data favor ongoing fueling of satellites from the IHM of the host group halo on ˜Mpc scales, I.e., from gas not initially associated with the galaxies upon infall. Consequently, the color

  11. An intense transmission spectrometer for ISIS

    Newport, R.J.; Howells, W.S.

    1986-07-01

    The report seeks to outline a design for an intense transmission spectrometer (ITS) suitable for installation on the pulsed neutron source ISIS. The performance of the instrument is evaluated and several examples of the areas of science made accessible are discussed. It is shown that the proposed design will represent a scientifically valuable and cost-effective addition to the present suite of ISIS instruments. (author)

  12. Contamination measurements with quadrupole mass spectrometer

    Bohatka, S.; Berecz, I.; Langer, G.

    1981-01-01

    A sensitive quadrupole mass spectrometer of our own construction was used for different purity measurements. The analysis of gases in operating rooms showed a 1 ppm-10 5 ppm concentration of narcotics and helped to develop an effective and cheap method for regenerating narcotic filters. We regularly control the gases used in radioactive pollution measurements by internal GM counters and in radiocarbon dating technique. Combustion products and the gases of a fermenter are investigated for industrial application. (orig.) [de

  13. Single crystal spectrometer FOX at KENS

    Takahashi, M.

    2001-01-01

    Single crystal spectrometer FOX installed at H1 thermal neutron line on KENS has been renewed recently for the measurement of very weak scattering. We have installed a multidetector system of 36 linearly placed 3 He detectors with collimators instead of former four-circle diffractometer and scintillator detectors. Though the system is quite simple, a large two-dimensional reciprocal space is observed effectively with high S/N rate on new FOX. (author)

  14. Resolution of a triple axis spectrometer

    Nielsen, Mourits; Bjerrum Møller, Hans

    1969-01-01

    A new method for obtaining the resolution function for a triple-axis neutron spectrometer is described, involving a combination of direct measurement and analytical calculation. All factors which contribute to the finite resolution of the instrument may be taken into account, and Gaussian...... or experimentally determined probability distributions may be used. The application to the study of the dispersion relation for excitations in a crystal is outlined...

  15. Frequency-feedback cavity enhanced spectrometer

    Hovde, David Christian; Gomez, Anthony

    2015-08-18

    A spectrometer comprising an optical cavity, a light source capable of producing light at one or more wavelengths transmitted by the cavity and with the light directed at the cavity, a detector and optics positioned to collect light transmitted by the cavity, feedback electronics causing oscillation of amplitude of the optical signal on the detector at a frequency that depends on cavity losses, and a sensor measuring the oscillation frequency to determine the cavity losses.

  16. Mobile environment for an emission spectrometer

    Radziak, Kamil; Litwin, Dariusz; Galas, Jacek; Tyburska-Staniewska, Anna; Ramsza, Andrzej

    2017-08-01

    The paper describes a mobile application to be used in a chemical analytical laboratory. The program running under the control of Android operating system allows for preview of measurements recorded by the emission spectrometer. Another part of the application monitors operational and configuration parameters of the device in real time. The first part of this paper includes an overview of the atomic spectrometry. The second part contains a description of the application and its further potential development direction.

  17. Calibration of a leak detection spectrometer

    Geller, R.

    1958-01-01

    This paper describes a study of the possible methods for calibrating a leak detection spectrometer, and the estimation of outputs from the leaks is considered. With this in mind the question of sensitivity of leak detection is tackled on a very general level; first the sensitivity of the isolated instrument is determined, and then the sensitivity of an instrument connected to an installation where leaks may be suspected. Finally, practical solutions are proposed. (author) [fr

  18. Superconducting RF separator for Omega Spectrometer

    1977-01-01

    The photo shows an Nb-deflector for the superconducting RF separator ready for installation in its cryostat (visible at the back). Each deflector was about 3 m long. L. Husson and P. Skacel (Karlsruhe) stand on the left, A. Scharding (CERN) stands on the right. This particle separator, the result of a collaboration between the Gesellshaft für Kernforschung, Karlsruhe, and CERN was installed in the S1 beam line to Omega spectrometer. (See Annual Report 1977.)

  19. Some characteristics of a miniature neutron spectrometer

    Sekimoto, H.; Oishi, K.; Hojo, K.; Hojo, T.

    1984-01-01

    Some characteristics of an NE213 miniature spherical spectrometer for in-assembly fast-neutron spectrometry were measured. As the bubbling time changed, the pulse-height did not change appreciably, but the n-γ discrimination characteristics changed considerably. As the count rate changed, the pulse-height did not change appreciably, and the change of the n-γ discrimination characteristics was acceptable. The neutron response function was measured to be almost isotropic except for the backward direction. (orig.)

  20. The VESUVIO Spectrometer Now and When?

    Seel, A G; Krzystyniak, M; Fernandez-Alonso, F

    2014-01-01

    The current layout and mechanics of the VESUVIO spectrometer are presented in light of spectroscopic measurements using electron-volt neutrons. A brief background to the theoretical framework of deep inelastic neutron scattering is presented, with focus on data collection and instrumental design. The current capabilities and research themes for VESUVIO are discussed, and possible future instrumental developments highlighted which will enhance the instrument's ability to meet scientific inquiry and expectation

  1. The VESUVIO Spectrometer Now and When?

    Seel, A. G.; Krzystyniak, M.; Fernandez-Alonso, F.

    2014-12-01

    The current layout and mechanics of the VESUVIO spectrometer are presented in light of spectroscopic measurements using electron-volt neutrons. A brief background to the theoretical framework of deep inelastic neutron scattering is presented, with focus on data collection and instrumental design. The current capabilities and research themes for VESUVIO are discussed, and possible future instrumental developments highlighted which will enhance the instrument's ability to meet scientific inquiry and expectation.

  2. A new thermal ionisation mass spectrometer

    Haines, C.; Merren, T.O.; Unsworth, W.D.

    1979-01-01

    The Isomass 54E, a new thermal ionisation mass spectrometer for precise measurements of isotopic composition is described in detail. It combines the fruits of three development pro ects, viz. automation, energy filters and extended geometry with existing micromass expertise and experience. The hardware and software which are used for the automation as well as the energy filter used, are explained. The 'extended geometry' ion optical system adopted for better performance is discussed in detail. (K.B.)

  3. Hypernuclear physics with a neutral meson spectrometer

    Peng, J.C.

    1993-01-01

    The (K - , π degrees) reaction, which complements the (K - , π - ) and the (π + , K + ) reactions, offers another means to study hypernuclear physics. The physics motivation for measuring the (K - , π degrees) reaction is discussed. The feasibility for detecting π degrees using the LAMPF Neutral Meson Spectrometer is studied with Monte-Carlo simulations. We conclude that the (K - , π degrees) reaction can be well measured at existing kaon beam lines

  4. Nuclear quadrupole resonance spectrometer for chlorine compounds

    Lasanda, J.

    1976-01-01

    An NQR spectrometer is described based on a superregenerative oscillator for high sensitivity. The application of a Pound-Knight type oscillator using field effect transistors resulted in higher stability of oscillation amplitude in the desired range of 10 to 50 MHz. The use of a current source allowed to set good signal-to-noise ratio independently of the amplitude of oscillations. For synchronizing of both oscillators a balanced modulator was used. (author)

  5. Fourier Transform Spectrometer Controller for Partitioned Architectures

    Tamas-Selicean, Domitian; Keymeulen, D.; Berisford, D.

    2013-01-01

    The current trend in spacecraft computing is to integrate applications of different criticality levels on the same platform using no separation. This approach increases the complexity of the development, verification and integration processes, with an impact on the whole system life cycle. Resear......, such as avionics and automotive. In this paper we investigate the challenges of developing and the benefits of integrating a scientific instrument, namely a Fourier Transform Spectrometer, in such a partitioned architecture....

  6. One module of the ALICE photon spectrometer

    Maximilien Brice

    2006-01-01

    The first module for the ALICE photon spectrometer has been completed. Each of the five modules will contain 3584 lead-tungstate crystals, a material as transparent as ordinary silica glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, allowing the energy of electrons, positrons and photons to be measured through the 17 920 detection channels.

  7. MacMS: A Mass Spectrometer Simulator: Abstract of Issue 9906M

    Bigger, Stephen W.; Craig, Robert A.

    1999-10-01

    , fixed-value range and gain settings, which can be used to enhance the resolution and sensitivity of the instrument respectively. Figure 1. The "Path" module of MacMS showing the control panel (upper section) and graphics display region (lower section). The graphics display region incorporates a "data collector", which includes a "Grab" button to collect data and an area where data are displayed. Figure 2. The "Spectrometer" module of MacMS showing the control panel (upper section) and a graphics display region (lower section). A mass spectrum is produced in the graphics display region upon scanning. A "data collector" similar to that of the "Path" module forms part of the graphics display region. Hardware and Software Requirements Literature Cited Kiser, R. N. Introduction to Mass Spectrometry and its Applications; Prentice-Hall: Englewood Cliffs, N. J., 1965; pp 1-3; pp 32-65. Johnstone, R. A. W.; Rose, M. E. Mass Spectrometry for Chemists and Biochemists, 2nd ed.; Cambridge University Press: Cambridge, 1996. Hill, H. C.; Loudon, A. G. Introduction to Mass Spectrometry; 2nd ed.; Heyden: London, 1972; p 5. Farmer, J. B. In Mass Spectrometry, McDowell, C. A., Ed.; McGraw-Hill: New York, 1963; pp 10-11. Message, G. M. Practical Aspects of Gas Chromatography-Mass Spectrometry, Wiley: New York, 1984; Chapter 3. CRC Handbook of Chemistry and Physics, 55th ed.; CRC: Cleveland, 1974.

  8. X-ray photoelectron spectrometer calibration and thin film investigations on germanium oxides

    Deegan, Terri

    1998-01-01

    The first aim of this project was the characterisation of the VG Scientific Clam 100 based, XPS (X-ray Photoelectron Spectroscopy). Spectrometer in the Physics department at Dublin City University Detailed energy scale and intensity scale calibrations were carried out using sputter-cleaned Au (Gold), Ag (Silver), Cu (Copper) and Pd (Palladium) foil samples. Analysis of these calibration spectra against standard reference spectra led to an accurate energy calibration and the production of indi...

  9. Two-lens spectrometer for. beta. polarimetry

    Holdsworth, D; Paul, D [Toronto Univ., Ontario (Canada). Dept. of Physics

    1984-06-01

    A test spectrometer has been built having four degrees of freedom which have been varied to optimize the transmission in a configuration in which the image distance is large compared to the object distance. Iron-clad magnets of 15 cm effective inside diameter were used. Within the limits of the primary magnet field, the optimized transmission T (%. of 4..pi.. sr) increases as the source is advanced through the magnet towards the polarimeter, approximately as T=5.1 exp(zsub(s)/10.5), where zsub(s) is in cm, measured from the position of peak axial field. When the source-image distance is 1.8 m the optimum separation of the peak axial fields of the magnets is 67+-1 cm and the spectrometer transmission is the same for parallel or antiparallel fields. When operating in the optimum configuration, the spectrometer accepts particles with initial trajectories from 18/sup 0/ to 42/sup 0/ relative to the axis and delivers them at the target with half-angle of convergence less than 4.1/sup 0/.

  10. Miniature Neutron-Alpha Activation Spectrometer

    Rhodes, E.; Goldsten, J.

    2001-01-01

    We are developing a miniature neutron-alpha activation spectrometer for in situ analysis of samples including rocks, fines, ices, and drill cores, suitable for a lander or Rover platform, that would meet the severe mass, power, and environmental constraints of missions to the outer planets. In the neutron-activation mode, a gamma-ray spectrometer will first perform a penetrating scan of soil, ice, and loose material underfoot (depths to 10 cm or more) to identify appropriate samples. Chosen samples will be analyzed in bulk in neutron-activation mode, and then the sample surfaces will be analyzed in alpha-activation mode using Rutherford backscatter and x-ray spectrometers. The instrument will provide sample composition over a wide range of elements, including rock-forming elements (such as Na, Mg, Si, Fe, and Ca), rare earths (Sm and Eu for example), radioactive elements (K, Th, and U), and light elements present in water, ices, and biological materials (mainly H, C, O, and N). The instrument is expected to have a mass of about l kg and to require less than 1 W power. Additional information is contained in the original extended abstract.

  11. High speed, High resolution terahertz spectrometers

    Kim, Youngchan; Yee, Dae Su; Yi, Miwoo; Ahn, Jaewook

    2008-01-01

    A variety of sources and methods have been developed for terahertz spectroscopy during almost two decades. Terahertz time domain spectroscopy (THz TDS)has attracted particular attention as a basic measurement method in the fields of THz science and technology. Recently, asynchronous optical sampling (AOS)THz TDS has been demonstrated, featuring rapid data acquisition and a high spectral resolution. Also, terahertz frequency comb spectroscopy (TFCS)possesses attractive features for high precision terahertz spectroscopy. In this presentation, we report on these two types of terahertz spectrometer. Our high speed, high resolution terahertz spectrometer is demonstrated using two mode locked femtosecond lasers with slightly different repetition frequencies without a mechanical delay stage. The repetition frequencies of the two femtosecond lasers are stabilized by use of two phase locked loops sharing the same reference oscillator. The time resolution of our terahertz spectrometer is measured using the cross correlation method to be 270 fs. AOS THz TDS is presented in Fig. 1, which shows a time domain waveform rapidly acquired on a 10ns time window. The inset shows a zoom into the signal with 100ps time window. The spectrum obtained by the fast Fourier Transformation (FFT)of the time domain waveform has a frequency resolution of 100MHz. The dependence of the signal to noise ratio (SNR)on the measurement time is also investigated

  12. Automation of a thermal ionisation mass spectrometer

    Pamula, A.; Leuca, M.; Albert, S.; Benta, Adriana

    2001-01-01

    A thermal ionization mass spectrometer was upgraded in order to be monitored by a PC. A PC-LMP-16 National Instruments data acquisition board was used for the ion current channel and the Hall signal channel. A dedicated interface was built to allow commands from the computer to the current supply of the analyzing magnet and to the high voltage unit of the mass spectrometer. A software application was worked out to perform the adjustment of the spectrometer, magnetic scanning and mass spectra acquisition, data processing and isotope ratio determination. The apparatus is used for isotope ratio 235 U/ 238 U determination near the natural abundance. A peak jumping technique is applied to choose between the 235 U and 238 U signal, by switching the high voltage applied to the ion source between two preset values. This avoids the delay between the acquisition of the peaks of interest, a delay that would appear in the case of a 'pure' magnetic scanning. Corrections are applied for the mass discrimination effects and a statistical treatment of the data is achieved. (authors)

  13. VERITAS: Versatile Triple-Axis Spectrometer

    Park, Sung Il

    2006-04-15

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, {approx} 5 m Curved Guide, {approx} 26 m w/ R 1500 m Straight Guide before the Instrument, {approx} 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world.

  14. VERITAS: Versatile Triple-Axis Spectrometer

    Park, Sung Il

    2006-04-01

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, ∼ 5 m Curved Guide, ∼ 26 m w/ R 1500 m Straight Guide before the Instrument, ∼ 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world

  15. What Happened with Spectrometer Magnet 2B

    Green, Michael A.

    2010-01-01

    The spectrometer solenoid is supposed to be the first magnets installed in MICE (1)-(4). This report described what happened during the test of the MICE spectrometer solenoid 2B. First, the report describes the temperatures in the magnet, the cooler top plate and the shield during the run where the magnet quenched at 258 A. During this quench, a lead between the bottom of the HTS leads and the diode bank burned out causing the magnet to quench. Second, three methods for measuring the net heat flow into the cold mass are described. Third, there is a discussion of possible resistive heating in the HTS leads between liquid helium temperature and the copper plate, which is at about 50 K. Fourth, there is a discussion of the measured first stage heat loads in the magnet, when there is no current in the magnet. The first stage heat load calculations are based on knowing the first stage temperatures of the three two-stage pulse tube coolers and the single stage GM cooler. Fifth, the estimated heat load to the first stage when the magnet has current in it is discussed. Sixth, there is a comparison of the stage 1 heat loads in magnet 1A (5), magnet 2A (6), and magnet 2B (7). Finally there is a discussion of recommended changes for improving the spectrometer solenoids so that the coolers can keep them cold.

  16. Tools to probe the universe

    Lagage, P.O.; Augueres, J.L.; Amiaux, J.; Cara, Ch.; Fontignie, J.; Rio, Y.; Fermon, C.; Pannetier-Lecoeur, M.; De Vismes, A.; Cordier, B.; Fesquet, M.; Ferrando, Ph.; Authier, M.; Pantin, E.; Glicenstein, J.F.; Boulade, O.; Refregier, A.; Stolarczyk, Th.; Agnese, P.; Rodriguez, L.; Agnese, P.; Pigot, C.; Duband, L.; Limousin, O.; Delagnes, E.; Turck-Chieze, S.; Carton, P.H.; Starck, J.L.; Bournaud, F.; Teyssier, R.; Audit, E.; Brun, A.S.; Leca, P.; Menache, Ch.; Pomarede, D.; Thooris, B.; Meis, C.

    2009-01-01

    This special issue of Clefs CEA journal is entirely devoted to astrophysics and to the exploration and probing of the Universe. The second part of this dossier, described here, makes a status of the tools used to probe the universe: telescopes, imaging spectrometers, data processing and simulation. Content: A - Telescopes of the future: 1. Seeing further out: JWST: looking back on a past 13 billion years old, Space specifics: the learning curve to know-how, Fabricating a corona-graph mask, SVOM, a satellite to detect the explosions of the first stars to be formed in the Universe; 2. Seeing more precisely: SIMBOL-X, pioneering formation flying, ELT/METIS, a 42-meter giant, One hundred telescopes for the CTA arrays; 3. Seeing wider: Euclid, mapping the extragalactic sky, ANTARES: the neutrino, another cosmic messenger; B - The new generation of imaging spectrometers: Observing the Universe in the submillimeter spectral region, The X-ray Universe, Space cryo-coolers, Out in the extreme, tumultuous Universe, Probing the Sun with GOLF-NG, Focus: From light to imagery; C - Data analysis in astrophysics; D - Numerical simulation in astrophysics: Information technology and theoretical predictions in astrophysics, Supercomputers for a better understanding of the Universe, The visualization of astrophysical simulations, Godunov, a numerical platform for education and research

  17. Miniature Photonic Spectrometers and Filters for Astrophysics and Space Science

    Veilleux, Sylvain

    ratio of the waveguide cross-section and overall design of the Braggs and arrayed waveguide gratings to make them polarization-independent, and (4) increase the overall throughput of these gratings to >70% at 1 - 1.7 microns by changing the deposition method of the cladding material (silica) and reducing the scattering losses with the use of a newly commissioned electron beam writer that delivers higher resolution (down to a few nm instead of 8 nm). Two graduate students, already trained in the techniques relevant to this project, will lead the optimization, fabrication, and testing of these optoelectronic components. Up to three undergraduate students will also be involved with the research. A wide swath of astrophysical research, from spectroscopic studies of the distant universe to searches for biosignatures in the atmospheres of exoplanets, stands to benefit from these miniature spectrometers and filters on board future NASA balloon, CubeSat, Explorer, Probe-, Flagship-, and Surveyor class missions. The technical by-products of this effort will also offer benefits in fields far beyond astronomy, such as medicine, human science, petrochemistry, space geo-science, and quantum computing and communication. The names and contact information of five experts qualified to review this proposal were emailed directly to the two relevant Program Officers.

  18. Gas turbine

    Yang, Ok Ryong

    2004-01-01

    This book introduces gas turbine cycle explaining general thing of gas turbine, full gas turbine cycle, Ericson cycle and Brayton cycle, practical gas turbine cycle without pressure loss, multiaxial type gas turbine cycle and special gas turbine cycle, application of basic theory on a study on suction-cooling gas turbine cycle with turbo-refrigerating machine using the bleed air, and general performance characteristics of the suction-cooling gas turbine cycle combined with absorption-type refrigerating machine.

  19. Continuous flow isotope ratio mass spectrometer (CF-IRMS) and its applications in hydrocarbon research and exploration

    Kalpana, G.; Patil, D.J.; Kumar, B.

    2004-01-01

    Stable isotope ratio mass spectrometers have been widely used to determine the isotopic ratios of light elements such as hydrogen, carbon, nitrogen, oxygen and sulphur. Continuous Flow Isotope Ratio Mass Spectrometry (CFIRMS) provides reliable data on nanomole amount of sample gas without the need for cryogenic trapping using cold fingers as in dual inlet isotope ratio mass spectrometer. High sample throughput is achieved as the system is configured with automated sample preparation devices and auto samplers. This paper presents a brief description of CFIRMS exploration

  20. Tests of the space gamma spectrometer prototype at the JINR experimental facility with different types of neutron generators

    Litvak, M. L.; Vostrukhin, A. A.; Golovin, D. V.; Dubasov, P. V.; Zontikov, A. O.; Kozyrev, A. S.; Krylov, A. R.; Krylov, V. A.; Mitrofanov, I. G.; Mokrousov, M. I.; Repkin, A. N.; Timoshenko, G. N.; Udovichenko, K. V.; Shvetsov, V. N.

    2017-07-01

    The results of the tests of the HPGe gamma spectrometer performed with a planetary soil model and different types of pulse neutron generators are presented. All measurements have been performed at the experimental nuclear planetary science facility (Joint Institute for Nuclear Research) for the physical calibration of active gamma and neutron spectrometers. The aim of the study is to model a space experiment on determining the elemental composition of Martian planetary matter by neutron-induced gamma spectroscopy. The advantages and disadvantages of a gas-filled neutron generator in comparison with a vacuum-tube neutron generator are examined.

  1. [Design of Dual-Beam Spectrometer in Spectrophotometer for Colorimetry].

    Liu, Yi-xuan; Yan, Chang-xiang

    2015-07-01

    Spectrophotometers for colorimetry are usually composed of two independent and identical spectrometers. In order to reduce the volume of spectrophotometer for colorimetry, a design method of double-beam spectrometer is put forward. A traditional spectrometer is modified so that a new spectrometer can realize the function of double spectrometers, which is especially suitable for portable instruments. One slit is replaced by the double-slit, than two beams of spectrum can be detected. The working principle and design requirement of double-beam spectrometer are described. A spectrometer of portable spectrophotometer is designed by this method. A toroidal imaging mirror is used for the Czerny-Turner double-beam spectrometer in this paper, which can better correct astigmatism, and prevent the dual-beam spectral crosstalk. The results demonstrate that the double-beam spectrometer designed by this method meets the design specifications, with the spectral resolution less than 10 nm, the spectral length of 9.12 mm, and the volume of 57 mm x 54 mm x 23 mm, and without the dual-beam spectral overlap in the detector either. Comparing with a traditional spectrophotometer, the modified spectrophotometer uses a set of double-beam spectrometer instead of two sets of spectrometers, which can greatly reduce the volume. This design method can be specially applied in portable spectrophotometers, also can be widely applied in other double-beam spectrophotometers, which offers a new idea for the design of dual-beam spectrophotometers.

  2. Portable, remotely operated, computer-controlled, quadrupole mass spectrometer for field use

    Friesen, R.D.; Newton, J.C.; Smith, C.F.

    1982-04-01

    A portable, remote-controlled mass spectrometer was required at the Nevada Test Site to analyze prompt post-event gas from the nuclear cavity in support of the underground testing program. A Balzers QMG-511 quadrupole was chosen for its ability to be interfaced to a DEC LSI-11 computer and to withstand the ground movement caused by this field environment. The inlet system valves, the pumps, the pressure and temperature transducers, and the quadrupole mass spectrometer are controlled by a read-only-memory-based DEC LSI-11/2 with a high-speed microwave link to the control point which is typically 30 miles away. The computer at the control point is a DEC LSI-11/23 running the RSX-11 operating system. The instrument was automated as much as possible because the system is run by inexperienced operators at times. The mass spectrometer has been used on an initial field event with excellent performance. The gas analysis system is described, including automation by a novel computer control method which reduces operator errors and allows dynamic access to the system parameters

  3. Mixed gamma emitting gas standard and method

    McFarland, R.C.; McFarland, P.A.

    1986-01-01

    The invention in one aspect pertains to a method of calibrating gamma spectroscopy systems for gas counting in a variety of counting containers comprising withdrawing a precision volume of a mixed gamma-emitting gas standard from a precision volume vial and delivering the withdrawn precision volume of the gas standard to the interior of a gas counting container. Another aspect of the invention pertains to a mixed gamma-emitting gas standard, comprising a precision spherical vial of predetermined volume, multiple mixed emitting gas components enclosed within the vial, and means for withdrawing from the vial a predetermined amount of the components wherein the gas standard is used to calibrate a gamma spectrometer system for gas counting over a wide energy range without the use of additional standards. A third aspect comprehends a gamma spectrometer calibration system for gas counting, comprising a precision volume spherical glass vial for receiving mixed multiisotope gas components, and two tubular arms extending from the vial. A ground glass stopcock is positioned on each arm, and the outer end of one arm is provided with a rubber septum port

  4. Automation of an X-ray photoelectron spectrometer

    Ashury, M.R.

    2003-02-01

    The Institute of Solid State Physics of the Vienna University of Technology is established with an X-ray Photoelectron Spectrometer Kratos XSAM 800. In its original state the instrument enables measurements of photoelectron spectra in a semiautomatical mode. After mounting of the specimen an eventual surface cleaning by argon ion sputtering is possible. Next steps are setting of x-ray tube high voltage and current, start energy and energy range of spectrum and time of measurement. Data are obtained by an x-t plotter and evaluations are performed from the registration charts. If necessary, measured spectra have to be digitized by means of a scanner. In the Introduction of this thesis the principle of X-ray photoelectron spectrometry is treated including a number of practical examples. It shows that an automation allows an extension of the performance of the instrument. Details are remote controlled experiments, wider energy ranges with improved energy resolution. Furthermore, the digitized data treatment enables background subtration, determination of line positions and integrated signal strengths, and is the detection of lowlevel of lines (the peak with lowamplitude) possible. A further advantage is the computer assisted documentation and comparison of results from different specimens. After this description of the essential requirements different possible solutions of an automation are discussed. Thus, it is decided to develop a completely new hardware for a perfect control of the spectrometer. A further decision is to be made on the most efficient kind of micro processor. From the considerations follows a completely new control board with a transputer as multi tasking processor. The complete control unit consists of a digital system, an analog system and a power unit. The digital system controls settings and spectra accumulation and includes the transputer board, the pc-link card, the i/o-card and the step scanning control board. The analog system controls the

  5. Mapping methane emissions using the airborne imaging spectrometer AVIRIS-NG

    Thorpe, A. K.; Frankenberg, C.; Thompson, D. R.; Duren, R. M.; Bue, B. D.; Green, R. O.

    2017-12-01

    The next generation Airborne Visible/Infrared Imaging Spectrometer (AVIRIS-NG) has been used to survey large regions and map methane plumes with unambiguous identification of emission source locations. This capability is aided by real time detection and geolocation of gas plumes, permitting adaptive surveys and communication to ground teams for rapid follow up. We present results from AVIRIS-NG flight campaigns in Colorado, New Mexico, and California. Hundreds of plumes were observed, reflecting emissions from the energy sector that include hydraulic fracturing, gas processing plants, tanks, pumpjacks, and pipeline leaks. In some cases, plumes observed by AVIRIS-NG resulted in mitigation. Additional examples will be shown for methane from dairy lagoons, landfills, natural emissions, as well as carbon dioxide from power plants and refineries. We describe the unique capabilities of airborne imaging spectrometers to augment other measurement techniques by efficiently surveying key regions for methane point sources and supporting timely assessment and mitigation. We summarize the outlook for near- and longer-term monitoring capabilities including future satellite systems. Figure caption. AVIRIS-NG true color image subset with superimposed methane plume showing retrieved gas concentrations. Plume extends 200 m downwind of the southern edge of the well pad. Google Earth imagery with finer spatial resolution is also included (red box), indicating that tanks in the inset scene as the source of emissions. Five wells are located at the center of this well pad and all use horizontal drilling to produce mostly natural gas.

  6. First solar radio spectrometer deployed in Scotland, UK

    Monstein, Christian

    2012-10-01

    A new Callisto solar radio spectrometer system has recently been installed and set into operation at Acre Road Observatory, a facility of University of Glasgow, Scotland UK. There has been an Observatory associated with Glasgow University since 1757, and they presently occupy two different sites. The main observatory ('Acre Road') is close to the Garscube Estate on the outskirts of the city of Glasgow. The outstation ('Cochno', housing the big 20 inch Grubb Parsons telescope) is located farther out at a darker site in the Kilpatrick Hills. The Acre Road Observatory comprises teaching and research labs, a workshop, the main dome housing the 16 inch Meade, the solar dome, presently housing the 12 inch Meade, a transit house containing the transit telescope, a 3m HI radio telescope and a 408 MHz pulsar telescope. They also have 10 and 8 inch Meade telescopes and several 5 inch Celestron instruments. There is a small planetarium beneath the solar dome. The new Callisto instrument is mainly foreseen for scientific solar burst observations as well as for student projects and for 'bad-weather' outreach activities.

  7. Performance and robustness of a multi-user, multi-spectrometer system for INAA

    Peter Bode; Menno Blaauw

    2012-01-01

    The laboratory for instrumental neutron activation analysis at the Reactor Institute Delft, Delft University of Technology uses a network of 3 gamma-ray spectrometers with well-type detectors and 2 gamma-ray spectrometers with coaxial detectors, all equipped with modern sample changers, as well as 2 spectrometers with coaxial detectors at the two fast rabbit systems. A wide variety of samples is processed through the system, all at specific optimized (and thus different) analytical protocols, and using different combination of the spectrometer systems. The gamma-ray spectra are analyzed by several qualified operators. The laboratory therefore needs to anticipate on the occurrence of random and systematic inconsistencies in the results (such as bias, non-linearity or wrong assignments due to spectral interferences) resulting from differences in operator performance, selection of analytical protocol and experimental conditions. This has been accomplished by taking advantage of the systematic processing of internal quality control samples such as certified reference materials and blanks in each test run. The data from these internal quality control analyses have been stored in a databank since 1991, and are now used to assess the various method performance indicators as indicators for the method's robustness. (author)

  8. Satellite-borne time-of-flight particle spectrometer and its response to protons

    Shino, T.

    1994-01-01

    One of the purposes of the high energy particle (HEP) experiment of the GEOTAIL satellite launched in 1992 is the elucidation of plasma dynamics in the tail region of planetary magnetosphere. For that purpose, a low energy particle detector (LD) was on board, which mainly observed relatively low energy particles up to a few MeV. The LD is the particle spectrometer based on time of flight technique. In order to confirm further its sensitivity to high energy protons, the beam experiment was carried out at Waseda University using the engineering model of the LD spectrometer that is exactly the same as the launched one. The LD spectrometer is shown, and its functions are explained. The LD was designed to identify electrons of 30 - 400 keV, protons of 30 - 1500 keV, helium ions of 80 - 4000 keV, and heavy ions (mainly C, N and O) of 160 - 1500 keV. The relation of measured time of flight signals with energy signals is shown. There are several factors that determine the detection efficiency of the spectrometer, which are discussed. The experiment and the results are reported. (K.I.)

  9. Electronics for processing of data from a double collector isotopic ratio mass spectrometer

    Handu, V.K.

    1979-01-01

    The output data available from the mass spectrometer type MS-660 developed in the mass spectrometry section of Technical Physics Division of the Bhabha Atomic Research Centre, Bombay, for the determination of H/D ratios in liquid/gas sample consist of uncompensated mass 3 and mass 2 signals. After the mass 3 signal has been compensated for H 3 + formation, the on-line ratio of compensated mass 3 to mass 2 is calculated, displayed, and then printed on a printer for record. The electronic compensation circuit, the discrete voltage-to-frequency (V/F) converter circuit, the ratio calculating system using V/F converters, and a digital interface system for Hindustan Teleprinter to print out the ratios are explained. Results obtained on mass spectrometer MS-660 are presented. (auth.)

  10. Compact terahertz passive spectrometer with wideband superconductor-insulator-superconductor mixer.

    Kikuchi, K; Kohjiro, S; Yamada, T; Shimizu, N; Wakatsuki, A

    2012-02-01

    We developed a compact terahertz (THz) spectrometer with a superconductor-insulator-superconductor (SIS) mixer, aiming to realize a portable and highly sensitive spectrometer to detect dangerous gases at disaster sites. The receiver cryostat which incorporates the SIS mixer and a small cryocooler except for a helium compressor has a weight of 27 kg and dimensions of 200 mm × 270 mm × 690 mm. In spite of the small cooling capacity of the cryocooler, the SIS mixer is successfully cooled lower than 4 K, and the temperature variation is suppressed for the sensitive measurement. By adopting a frequency sweeping system using photonic local oscillator, we demonstrated a spectroscopic measurement of CH(3)CN gas in 0.2-0.5 THz range.

  11. Customized altitude-azimuth mount for a raster-scanning Fourier transform spectrometer

    Durrenberger, Jed E.; Gutman, William M.; Gammill, Troy D.; Grover, Dennis H.

    1996-10-01

    Applications of the Army Research Laboratory Mobile Atmospheric Spectrometer Remote Sensing Rover required development of a customized computer-controlled mount to satisfy a variety of requirements within a limited budget. The payload was designed to operate atop a military electronics shelter mounted on a 4-wheel drive truck to be above most atmospheric ground turbulence. Pointing orientation in altitude is limited by constraints imposed by use of a liquid nitrogen detector Dewar in the spectrometer. Stepper motor drives and control system are compatible with existing custom software used with other instrumentation for controlled incremental raster stepping. The altitude axis passes close to the center of gravity of the complete payload to minimize load eccentricity and drive torque requirements. Dovetail fixture mounting enables quick service and fine adjustment of balance to minimize stepper/gearbox drive backlash through the limited orientation range in altitude. Initial applications to characterization of remote gas plumes have been successful.

  12. Spectrometer for X-ray emission experiments at FERMI free-electron-laser

    Poletto, L.; Frassetto, F.; Miotti, P.; Di Cicco, A.; Iesari, F.; Finetti, P.; Grazioli, C.; Kivimäki, A.; Stagira, S.; Coreno, M.

    2014-01-01

    A portable and compact photon spectrometer to be used for photon in-photon out experiments, in particular x-ray emission spectroscopy, is presented. The instrument operates in the 25–800 eV energy range to cover the full emissions of the FEL1 and FEL2 stages of FERMI. The optical design consists of two interchangeable spherical varied-lined-spaced gratings and a CCD detector. Different input sections can be accommodated, with/without an entrance slit and with/without an additional relay mirror, that allow to mount the spectrometer in different end-stations and at variable distances from the target area both at synchrotron and at free-electron-laser beamlines. The characterization on the Gas Phase beamline at ELETTRA Synchrotron (Italy) is presented

  13. A specialized isotope mass spectrometer for noninvasive diagnostics of Helicobacter pylori infection in human beings

    Blashenkov, N. M.; Sheshenya, E. S.; Solov'ev, S. M.; Sachenko, V. D.; Gall, L. N.; Zarutskii, I. V.; Gall, N. R.

    2013-05-01

    A specialized isotope mass spectrometer for noninvasive diagnostics of Helicobacter pylori infection in human beings based on the carbon-13 isotope breath test has been designed and constructed. Important stages of the work included (i) calculating a low-aberration mass analyzer, (ii) manufacturing and testing special gas inlet system, and (iii) creating a small-size collector of ions. The proposed instrument ensures 13C/12C isotopic ratio measurement to within 1.7‰ (pro mille) accuracy, which corresponds to requirements for a diagnostic tool. Preliminary medical testing showed that the mass spectrometer is applicable to practical diagnostics. The instrument is also capable of measuring isotopic ratios of other light elements, including N, O, B (for BF2+ ions), Ar, Cl, and S.

  14. Frequency-scanning MALDI linear ion trap mass spectrometer for large biomolecular ion detection.

    Lu, I-Chung; Lin, Jung Lee; Lai, Szu-Hsueh; Chen, Chung-Hsuan

    2011-11-01

    This study presents the first report on the development of a matrix-assisted laser desorption ionization (MALDI) linear ion trap mass spectrometer for large biomolecular ion detection by frequency scan. We designed, installed, and tested this radio frequency (RF) scan linear ion trap mass spectrometer and its associated electronics to dramatically extend the mass region to be detected. The RF circuit can be adjusted from 300 to 10 kHz with a set of operation amplifiers. To trap the ions produced by MALDI, a high pressure of helium buffer gas was employed to quench extra kinetic energy of the heavy ions produced by MALDI. The successful detection of the singly charged secretory immunoglobulin A ions indicates that the detectable mass-to-charge ratio (m/z) of this system can reach ~385 000 or beyond.

  15. Direct mass measurements of neutron-deficient xenon isotopes using the ISOLTRAP mass spectrometer

    Dilling, J; Beck, D; Bollen, G; Herfurth, F; Kellerbauer, A G; Kluge, H J; Moore, R B; Scheidenberger, C; Schwarz, S; Sikler, G

    2004-01-01

    The masses of the noble-gas Xe isotopes with 114 $\\leq$ A $\\leq$ 123 have been directly measured for the first time. The experiments were carried out with the ISOLTRAP triple trap spectrometer at the online mass separator ISOLDE/CERN. A mass resolving power of the Penning trap spectrometer of $m/\\Delta m$ of close to a million was chosen resulting in an accuracy of $\\delta m \\leq 13$ keV for all investigated isotopes. Conflicts with existing, indirectly obtained, mass data by several standard deviations were found and are discussed. An atomic mass evaluation has been performed and the results are compared to information from laser spectroscopy experiments and to recent calculations employing an interacting boson model.

  16. Procedure and apparatus for controlling the ion energy in a mass spectrometer

    Fies, W J; Reeher, J R; Story, M S; Smith, R D

    1977-03-03

    The invention relates to a process and apparatus for adjusting the energy of ions of different masses in a mass spectrometer. Specifically, it concerns a mass spectrometer having a gas inlet and ionisation space. A multipole mass filter includes several electrodes. A focusing system connects the ionisation space and the mass filter. Provision is made for applying to the electrodes a mass adjusting voltage combining a high frequency voltage and a d.c. voltage of increasing amplitude, so that the ions of a pre-determined mass can be selected. This system also includes a device connected to the electrodes, sensitive to the mass adjusting voltage and enabling the energy of the ions to be adjusted to that of the selected ions, depending on the mass of the ions, by modifying the difference in potential between the ionisation volume and the mean potential of the electrodes .

  17. Progress in commercial TXRF spectrometer for semiconductors

    Nishihagi, K.

    2000-01-01

    In the scale down of ULSI devices, it is required to reduce contamination of metal or particle due to get higher yield. For the metallic contamination, we are trying to develop to get higher sensitivity in direct-TXRF method, however, VPD-TXRF is the most important method to get 10 7 to 10 8 atoms/cm 2 sensitivity. For the particle contamination, we have developed software to link TXRF spectrometer with particle counter because not only position or size but also composition analysis have got required. In semiconductor industries, there are two important changing for improvement on production management system as COO (Cost Of Ownership) or standardization. One is the size of wafer has changed from 200 mm to 300 mm. Against this, we have redesigned TXRF spectrometer for 300 mm wafer without down of sensitivity. The other is the production system has become completely automated. On this point, we have also redesigned to link TXRF spectrometer with SMIF (Standard Mechanical Interface) or FOUP (Front Opening Unified Pod) as mini-environment, and with SECS 2 (SEMI Equipment Communications Standard 2) or GEM 300 (Generic Equipment Model) as automatically standardization. We shall also introduce some applications about new materials using TXRF such as Ta 2 O 5 , ZrO 2 and HfO 2 for high-k materials, and also Ru, SRO and IrO 2 for electrode materials. Furthermore, we shall introduce our new equipment for thickness and composition analysis such as PZT, BST and MOCVD TiN thin films. (author)

  18. Metrology for terahertz time-domain spectrometers

    Molloy, John F.; Naftaly, Mira

    2015-12-01

    In recent years the terahertz time-domain spectrometer (THz TDS) [1] has emerged as a key measurement device for spectroscopic investigations in the frequency range of 0.1-5 THz. To date, almost every type of material has been studied using THz TDS, including semiconductors, ceramics, polymers, metal films, liquid crystals, glasses, pharmaceuticals, DNA molecules, proteins, gases, composites, foams, oils, and many others. Measurements with a TDS are made in the time domain; conversion from the time domain data to a frequency spectrum is achieved by applying the Fourier Transform, calculated numerically using the Fast Fourier Transform (FFT) algorithm. As in many other types of spectrometer, THz TDS requires that the sample data be referenced to similarly acquired data with no sample present. Unlike frequency-domain spectrometers which detect light intensity and measure absorption spectra, a TDS records both amplitude and phase information, and therefore yields both the absorption coefficient and the refractive index of the sample material. The analysis of the data from THz TDS relies on the assumptions that: a) the frequency scale is accurate; b) the measurement of THz field amplitude is linear; and c) that the presence of the sample does not affect the performance characteristics of the instrument. The frequency scale of a THz TDS is derived from the displacement of the delay line; via FFT, positioning errors may give rise to frequency errors that are difficult to quantify. The measurement of the field amplitude in a THz TDS is required to be linear with a dynamic range of the order of 10 000. And attention must be given to the sample positioning and handling in order to avoid sample-related errors.

  19. Ultra-compact MEMS FTIR spectrometer

    Sabry, Yasser M.; Hassan, Khaled; Anwar, Momen; Alharon, Mohamed H.; Medhat, Mostafa; Adib, George A.; Dumont, Rich; Saadany, Bassam; Khalil, Diaa

    2017-05-01

    Portable and handheld spectrometers are being developed and commercialized in the late few years leveraging the rapidly-progressing technology and triggering new markets in the field of on-site spectroscopic analysis. Although handheld devices were commercialized for the near-infrared spectroscopy (NIRS), their size and cost stand as an obstacle against the deployment of the spectrometer as spectral sensing components needed for the smart phone industry and the IoT applications. In this work we report a chip-sized microelectromechanical system (MEMS)-based FTIR spectrometer. The core optical engine of the solution is built using a passive-alignment integration technique for a selfaligned MEMS chip; self-aligned microoptics and a single detector in a tiny package sized about 1 cm3. The MEMS chip is a monolithic, high-throughput scanning Michelson interferometer fabricated using deep reactive ion etching technology of silicon-on-insulator substrate. The micro-optical part is used for conditioning the input/output light to/from the MEMS and for further light direction to the detector. Thanks to the all-reflective design of the conditioning microoptics, the performance is free of chromatic aberration. Complemented by the excellent transmission properties of the silicon in the infrared region, the integrated solution allows very wide spectral range of operation. The reported sensor's spectral resolution is about 33 cm-1 and working in the range of 1270 nm to 2700 nm; upper limited by the extended InGaAs detector. The presented solution provides a low cost, low power, tiny size, wide wavelength range NIR spectral sensor that can be manufactured with extremely high volumes. All these features promise the compatibility of this technology with the forthcoming demand of smart portable and IoT devices.

  20. Low energy x-ray spectrometer

    Woodruff, W.R.

    1981-01-01

    A subkilovolt spectrometer has been produced to permit high-energy-resolution, time-dependent x-ray intensity measurements. The diffracting element is a curved mica (d = 9.95A) crystal. To preclude higher order (n > 1) diffractions, a carbon x-ray mirror that reflects only photons with energies less than approx. 1.1 keV is utilized ahead of the diffracting element. The nominal energy range of interest is 800 to 900 eV. The diffracted photons are detected by a gold-surface photoelectric diode designed to have a very good frequency response, and whose current is recorded on an oscilloscope. A thin, aluminium light barrier is placed between the diffracting crystal and the photoelectric diode detector to keep any uv generated on or scattered by the crystal from illuminating the detector. High spectral energy resolution is provided by many photocathodes between 8- and 50-eV wide placed serially along the diffracted x-ray beam at the detector position. The spectrometer was calibrated for energy and energy dispersion using the Ni Lα 1 2 lines produced in the LLNL IONAC accelerator and in third order using a molybdenum target x-ray tube. For the latter calibration the carbon mirror was replaced by one surfaced with rhodium to raise the cut-off energy to about 3 keV. The carbon mirror reflection dependence on energy was measured using one of our Henke x-ray sources. The curved mica crystal diffraction efficiency was measured on our Low-Energy x-ray (LEX) machine. The spectrometer performs well although some changes in the way the x-ray mirror is held are desirable. 16 figures

  1. Microprocessor-controlled portable neutron spectrometer

    Hunt, G.F.; Kaifer, R.C.; Slaughter, D.R.; Strout, R.E. II; Rueppel, D.W.

    1979-01-01

    A neutron spectrometer that acquires and unfolds data in the field has been developed for use in the energy range from 1 to 20 MeV. The system includes an NE213 organic scintillation detector, automatic gain stabilization, automatically stabilized pulseshape discrimination, an LSl-11 microprocessor for control and data reduction, and a multichannel analyzer for data acquisition. The system, with the exception of the multichannel analyzer, is mounted in a suitcase 47 by 66 by 23.5 cm. The mass is 23.5 kg

  2. Simplified monte carlo simulation for Beijing spectrometer

    Wang Taijie; Wang Shuqin; Yan Wuguang; Huang Yinzhi; Huang Deqiang; Lang Pengfei

    1986-01-01

    The Monte Carlo method based on the functionization of the performance of detectors and the transformation of values of kinematical variables into ''measured'' ones by means of smearing has been used to program the Monte Carlo simulation of the performance of the Beijing Spectrometer (BES) in FORTRAN language named BESMC. It can be used to investigate the multiplicity, the particle type, and the distribution of four-momentum of the final states of electron-positron collision, and also the response of the BES to these final states. Thus, it provides a measure to examine whether the overall design of the BES is reasonable and to decide the physical topics of the BES

  3. Ion mobility spectrometer with virtual aperture grid

    Pfeifer, Kent B.; Rumpf, Arthur N.

    2010-11-23

    An ion mobility spectrometer does not require a physical aperture grid to prevent premature ion detector response. The last electrodes adjacent to the ion collector (typically the last four or five) have an electrode pitch that is less than the width of the ion swarm and each of the adjacent electrodes is connected to a source of free charge, thereby providing a virtual aperture grid at the end of the drift region that shields the ion collector from the mirror current of the approaching ion swarm. The virtual aperture grid is less complex in assembly and function and is less sensitive to vibrations than the physical aperture grid.

  4. SIMS device with quadrupole mass spectrometer

    Szigethy, D.; Riedel, M.

    1980-01-01

    A versatile secondary ion mass spectrometer (SIMS) has been designed and constructed. The device is applicable for dinamic and static SIMS investigations. The sputtering and ionisation can be studied simultaneously. Oil diffusion pumps and an auxiliary ion-getter pump are used. A commercial ion gun is used in the working chamber. The secondary ion optics assures the preliminary filtering of fast ions, and the collection of sputtered ions for a separate microprobe analysis. The performance of the apparatus is illustrated with examples. (R.J.)

  5. The Triple Axis and SPINS Spectrometers.

    Trevino, S F

    1993-01-01

    In this paper are described the triple axis and spin polarized inelastic neutron scattering (SPINS) spectrometers which are installed at the NIST Cold Neutron Research Facility (CNRF). The general principle of operation of these two instruments is described in sufficient detail to allow the reader to make an informed decision as to their usefulness for his needs. However, it is the intention of the staff at the CNRF to provide the expert resources for their efficient use in any given situation. Thus, this work is not intended as a user manual but rather as a guide into the range of applicability of the two instruments.

  6. An achromatic multipassage magnetic mass spectrometer

    Boulanger, P.; Baril, M.

    1999-01-01

    A design providing achromatic correction to a multipassage magnetic mass spectrometer previously described by the author is presented. The energy spatial dispersion caused by repeated passages in the magnetic prism is corrected by three supplementary mirrors placed in a reinjection loop. From this study one can see that we simultaneously eliminate the energy dispersion term C ΔE/E and the opening angle aberration term C α 2 and we may also eliminate the coupled aberration term C αΔE/E

  7. Photoacoustic Soot Spectrometer (PASS) Instrument Handbook

    Dubey, M [Los Alamos National Laboratory; Springston, S [Brookhaven National Laboratory; Koontz, A [Pacific Northwest National Laboratory; Aiken, A [Los Alamos National Laboratory

    2013-01-17

    The photoacoustic soot spectrometer (PASS) measures light absorption by aerosol particles. As the particles pass through a laser beam, the absorbed energy heats the particles and in turn the surrounding air, which sets off a pressure wave that can be detected by a microphone. The PASS instruments deployed by ARM can also simultaneously measure the scattered laser light at three wavelengths and therefore provide a direct measure of the single-scattering albedo. The Operator Manual for the PASS-3100 is included here with the permission of Droplet Measurement Technologies, the instrument’s manufacturer.

  8. The H1 forward muon spectrometer

    Kenyon, I.R.; Phillips, H.; Cronstroem, H.I.; Hedberg, V.; Jacobsson, C.; Joensson, L.; Lohmander, H.; Nyberg, M.; Biddulph, P.; Finnegan, P.; Foster, J.; Gilbert, S.; Hilton, C.; Ibbotson, M.; Mehta, A.; Sutton, P.; Stephens, K.; Thompson, R.

    1993-02-01

    The H1 detector started taking data at the electron- proton collider HERA in the beginning of 1992. In HERA 30 GeV electrons collide with 820 GeV protons giving a strong boost of the centre-of-mass system in the direction of the proton, also called the forward region. For the detection of high momentum muons in this region a muon spectrometer has been constructed, consisting of six drift chamber planes, three either side of a toroidal magnet. A first brief description of the system and its main parameters as well as the principles for track reconstruction and Τ 0 determination is given. (orig.)

  9. Particulate contamination spectrometer. Volume 1: Technical report

    Schmitt, R. J.; Boyd, B. A.; Linford, R. M. F.

    1975-01-01

    A laser particulate spectrometer (LPS) system was developed to measure the size and speed distributions of particulate (dusts, aerosols, ice particles, etc.) contaminants. Detection of the particulates was achieved by means of light scattering and extinction effects using a single laser beam to cover a size range of 0.8 to 275 microns diameter and a speed range of 0.2 to 20 meter/second. The LPS system was designed to operate in the high vacuum environment of a space simulation chamber with cold shroud temperatures ranging from 77 to 300 K.

  10. Prismatic analyzer concept for neutron spectrometers

    Birk, Jonas O.; Marko, M.; Freeman, P.G.

    2014-01-01

    readily be combined with advanced focussing geometries and with multiplexing instrument designs. We present a combination of simulations and data showing three different energies simultaneously reflected from one analyser. Experiments were performed on a cold triple axis instrument and on a prototype...... inverse geometry Time-of-flight spectrometer installed at PSI, Switzerland, and shows excellent agreement with the predictions. Typical improvements will be 2.0 times finer resolution and a factor of 1.9 in flux gain compared to a focussing Rowland geometry, or of 3.3 times finer resolution and a factor...

  11. AMS, a particle spectrometer in space

    Buenerd, M.; Ohlsson-Malek, F.; Ren, Z.L.; Santos, D.; Thuillier, T.

    1997-01-01

    The Alpha Magnetic Spectrometer (AMS) is a detector designed for extraterrestrial study of anti-matter, matter and dark matter. A precursor flight and on the STS-91 flight of the shuttle is planned to take place on May 1998. AMS will be installed on the International Space Station in January 2002 where it will be operated next, for three to five years. The contributions of the ISN to the project on the shuttle (aerogel threshold Cherenkov counter) as well as the steps to build a RICH detector for AMS on the ISSA are explained here below. (authors)

  12. Dual waveband compact catadioptric imaging spectrometer

    Chrisp, Michael P.

    2012-12-25

    A catadioptric dual waveband imaging spectrometer that covers the visible through short-wave infrared, and the midwave infrared spectral regions, dispersing the visible through shortwave infrared with a zinc selenide grating and midwave infrared with a sapphire prism. The grating and prism are at the cold stop position, enabling the pupil to be split between them. The spectra for both wavebands are focused onto the relevant sections of a single dual waveband detector. Spatial keystone distortion is controlled to less than one tenth of a pixel over the full wavelength range, facilitating the matching of the spectra in the midwave infrared with the shorter wavelength region.

  13. A novel spectrometer for neutrino experiments

    Pasqualini, Laura

    2015-01-01

    The WA104-NESSiE program developed in the context of the CERN Neutrino Platform, includes an innovative spectrometer to measure the charge and the momentum of muons in 0.5-5 GeV/c range. A tracking apparatus with a spatial resolution of 1 mm was designed, to be placed in a magnetized air volume in order to achieve a charge resolution and mis-identification of better than 1% at 1 GeV/c. Preliminary results obtained by detecting cosmic ray muons are reported.

  14. Some physics highlights from the EUROBALL spectrometer

    Korten, W.

    2004-01-01

    The latest generation of large γ-ray spectrometers, such as EUROBALL, has boosted the explorations of nuclei under extreme conditions especially at the limits of angular momentum and at finite temperatures. But the coupling of this instrument to very selective ''ancillary'' devices allows for more and more refined investigations of the third important degree of freedom in contemporary nuclear-structure studies, the isospin. This contribution summarises some of the recent highlights from the physics at EUROBALL obtained in some of the different areas of nuclear-structure research

  15. Calibration of an electron volt neutron spectrometer

    Mayers, J.; Adams, M.A.

    2011-01-01

    The procedure for calibrating the VESUVIO eV neutron spectrometer at the ISIS neutron source is described. VESUVIO is used primarily to measure the momentum distribution n(p) of atoms, by inelastic scattering of very high energy (5-150 eV) neutrons. The results of the calibrations show that measurements of n(p) in atoms with masses lower than 16 amu can be measured with a resolution width ∼25% of the intrinsic peak widths in the current instrument configuration. Some suggestions as to how the instrument resolution could be significantly improved are made.

  16. Bragg rotor spectrometer for tokamak diagnostics

    Barnsley, R.; Evans, K.D.; Peacock, N.J.

    1986-01-01

    This paper discusses high thru'put broad band (1-24 angstrom) x-ray spectrometer having absolute calibration for wavelength and intensity and demonstrated on the DITE tokamak. This instrument has a self-contained vacuum system which allows full spatial scans of the DITE plasma. Data acquisition and drive mechanism for the rotor and filter selection are operated remotely from a SADA. Results are presented of fast spectral surveys and λ-lock time-evolution of impurity emission during neutral beam injection. Spatial scans of the absolute impurity concentrations are derived

  17. Fast neutron spectrometer with pulse shape discrimination

    Verbitsky, S.S.

    1978-01-01

    A fast neutron spectrometer with a stilbene single crystal designed to operate at high pulsed count rate has been described. Making use of identification and rejection of events, accompanied by pile-up, allowed to increase permissible count rates by an order of magnitude. The results of energy dependence of signal amplitude and shape relative anisotropy in stilbene in the range 4-10 and 2-8 MeV respectively have been presented. Taking into account anisotropy of the detector-scintillation properties allowed to improve particle discrimination. (Auth.)

  18. A dilepton spectrometer project for SIS

    Meritet, L.

    1991-01-01

    An experimental project is presented to study e + e - pairs production in nucleus-nucleus collisions at GSI. Dileptons appear to be a clean probe to investigate in medium properties of nuclear form factors, baryon excitations (Δ) and mesons (π-dispersion relation; ρ-form factor) at high nuclear matter densities. The design of the detector system will be based on the experience obtained with the DLS-spectrometer at LBL and other dilepton detector systems in operation at high energy facilities. The project includes a fast electron trigger provided by a ring imaging Cherenkov detector with a segmented photomultiplier array. (author) 14 refs., 5 figs

  19. Electro-optic imaging Fourier transform spectrometer

    Chao, Tien-Hsin (Inventor); Znod, Hanying (Inventor)

    2009-01-01

    An Electro-Optic Imaging Fourier Transform Spectrometer (EOIFTS) for Hyperspectral Imaging is described. The EOIFTS includes an input polarizer, an output polarizer, and a plurality of birefringent phase elements. The relative orientations of the polarizers and birefringent phase elements can be changed mechanically or via a controller, using ferroelectric liquid crystals, to substantially measure the spectral Fourier components of light propagating through the EIOFTS. When achromatic switches are used as an integral part of the birefringent phase elements, the EIOFTS becomes suitable for broadband applications, with over 1 micron infrared bandwidth.

  20. Computerized mass spectrometer data system at LLL

    Friesen, R.D.; Dupzyk, R.J.

    1976-01-01

    The data systems on the three mass spectrometers at LLL are computer-controlled, pulse-counting systems synchronized to a repeatedly swept magnetic field. The data are accumulated in the memory of the computer or in a Nuclear Data ND 180 in a multi-scaler mode of operation. This mode of data acquisition allows a continuous check of the background stability and makes tune-up easier. But the main benefit is a reduction in the required ion emission rate stability. By the use of standards to set the system dead time, we have been able to utilize the sensitivity of a pulse counting system without the expense of exotic equipment