WorldWideScience

Sample records for university dorm room

  1. Food environments in university dorms: 20,000 calories per dorm room and counting.

    Science.gov (United States)

    Nelson, Melissa C; Story, Mary

    2009-06-01

    Few young adults meet national dietary recommendations. Although home food availability likely has important influences on dietary intake, little research has examined this issue among young adults. The objective of this research was to conduct a detailed, observational assessment of food and beverages available in college-student dormitory rooms. Dormitory-residing students (n=100) were recruited from a large, public university. Research staff completed a detailed inventory of food and beverages in the dorm rooms, including nutrient contents and purchasing sources. Data were collected and analyzed in 2008. The mean number of food and beverage items per participant was 47 (range: 0-208), with 4% of participants not having any food or beverages. More than 70% of students had each of the following types of items: salty snacks, cereal or granola bars, main dishes, desserts or candy, and sugar-sweetened beverages. Fewer students had low-calorie beverages, fruits and vegetables, dairy products, tea/coffee, and 100% fruit/vegetable juice. The average number of calories per dorm room was 22,888. Items purchased by parents had a higher calorie and fat content than items purchased by students. Findings indicate that students maintain a wide array of food and beverages in their dormitory rooms. Parents purchased a substantial amount of food for their children's dormitory rooms, and these food items were less healthful than the food that students purchased. The foods observed in college students' living spaces may have an important impact on eating habits. Overall, young adult-oriented obesity prevention efforts are needed, and improving the various facets of campus food environments may mark an important component of such strategies.

  2. Dampness in dorm rooms and its associations with allergy and airways infections among college students in China: a cross-sectional study.

    Science.gov (United States)

    Sun, Y; Zhang, Y; Sundell, J; Fan, Z; Bao, L

    2009-08-01

    A cross-sectional study was carried out at Tianjin University campus, China, from February 21 to June 10, 2006, to survey the association between dampness in dorms, and allergy and airways infections among college students. The health and dampness conditions were self-reported by 3436 students living in 1511 dorm rooms located in 13 buildings on the campus. The buildings were selected according to their positions, construction periods and occupant densities. The symptoms involved wheezing, dry cough during night, rhinitis, eczema, cold/flu, ear inflammation, pneumonia and tuberculosis. The indoor moisture signs were mould/damp spots on walls, ceilings and floors; suspected or ever happened water damage; condensation on windowpane in winter and odours perceived by subjects themselves. There was a significant positive association between condensation and dry cough. Eczema was often reported in rooms with moisture problem. Dampness was a significant risk factor for common cold. Dampness problems in dorms of Chinese students are a risk factor for allergic symptoms, and hence there is a need for dorm environment improvement. Health problems related to ventilation and microbiology problems in dorms should be further studied.

  3. Dampness at dorm and its associations with allergy and airways infection among college students in China: a cross-sectional study.

    Science.gov (United States)

    Sun, Y; Zhang, Y; Sundell, J; Fan, Z; Bao, L

    2009-04-01

    A cross-sectional study was carried out at Tianjin University campus, China, from February 21 to June10, 2006, to survey the association between dampness in dorms and allergy and airways infection among college students. The health and dampness condition were self-reported by 3436 students living in 1511 dorm rooms located in 13 buildings on the campus. The buildings were selected according to their positions, construction periods and occupant densities. The allergy and airways infection symptoms involved wheezing, dry cough during night, rhinitis, eczema, cold/flu, ear inflammation, pneumonia and tuberculosis. The indoor moisture signs were mould/damp spots on walls, ceilings and floors; suspected or ever happened water damage; condensation on windowpane in winter and odours perceived by subjects themselves. This study showed there was significantly positive association between condensation and dry cough. Eczema was often reported in rooms with suspected moisture problem. Dampness was a significantly risk factor for common cold. This paper indicated that dampness problem at dorms of Chinese students was a risk factor in irritating allergic symptoms, and hence there is a need for dorm environment improvement. The ventilation and microbiology problems in dorm environment corresponding to dampness should be further studied, especially when it is associated to occupants' health.

  4. Ventilation and dampness in dorms and their associations with allergy among college students in China: a case-control study

    DEFF Research Database (Denmark)

    Sun, Y; Zhang, Y; Bao, L

    2011-01-01

    Abstract To study the associations between dorm environment and occupants' health, a nested case-control study on 348 college students was carried out in 2006-2007 at Tianjin University, China. Two hundred and twenty-three dorm rooms where the 'cases' and 'controls' resided were inspected. Measured...... the window) for wheezing was 3.56 [95% Confident Interval (CI): 1.56-8.14] and for rhinitis 2.81 (95% CI: 1.32-5.97). The AOR of a low air change rate (below the median value of 0.7/h) for wheezing was 2.28 (95% CI: 1.38-3.75) and for dry cough 2.26 (95% CI: 1.08-4.75). The prevalence of students...... with allergic symptoms in dorm rooms decreased with increasing ventilation rate. The combination of a 'localized moldy/moisture indicator' and a low air change rate significantly increased the AOR of case status to 13.35 (95% CI: 3.73-47.83), compared to the reference condition with no-dampness and high...

  5. Dampness at dorm and its associations with allergy and airways infections among college students in China: a cross-sectional study

    DEFF Research Database (Denmark)

    Sun, Y.; Zhang, Y.; Sundell, Jan

    2009-01-01

    . The indoor moisture signs were mould/damp spots on walls, ceilings and floors; suspected or ever happened water damage; condensation on windowpane in winter and odours perceived by subjects themselves. There was a significant positive association between condensation and dry cough. Eczema was often reported...... in rooms with moisture problem. Dampness was a significant risk factor for common cold.Practical Implications Dampness problems in dorms of Chinese students are a risk factor for allergic symptoms, and hence there is a need for dorm environment improvement. Health problems related to ventilation...

  6. Dampness at dorm and its associations with allergy and airways infection among college students in China: a cross-sectional study

    DEFF Research Database (Denmark)

    Sun, Y.; Zhang, Y.; Sundell, Jan

    2009-01-01

    and tuberculosis. The indoor moisture signs were mould/damp spots on walls, ceilings and floors; suspected or ever happened water damage; condensation on windowpane in winter and odours perceived by subjects themselves. This study showed there was significantly positive association between condensation and dry...... cough. Eczema was often reported in rooms with suspected moisture problem. Dampness was a significantly risk factor for common cold.This paper indicated that dampness problem at dorms of Chinese students was a risk factor in irritating allergic symptoms, and hence there is a need for dorm environment...

  7. Living Green: Examining Sustainable Dorms and Identities

    Science.gov (United States)

    Watson, Lesley; Johnson, Cathryn; Hegtvedt, Karen A.; Parris, Christie L.

    2015-01-01

    Purpose: The purpose of this study was to examine the effects of living in "green" dorms on students' environmentally responsible behaviors (ERBs), in concert with other factors, including individual identity and social context in the form of behavior modeling by peers. Design/methodology/approach: The sample of 243 consists of students…

  8. Chasing Aleck: the story of a dorm.

    Science.gov (United States)

    Edwards, R A R

    2007-01-01

    A student raised a hand in class and asked, "Why is this dorm named after Alexander Graham Bell?" On a deaf campus, this was a loaded question. Bell was an oralist, opposed to sign language. He was a eugenicist, opposed to deaf marriages. Indeed, the more I thought about it, the better this question got. Why did the school name a dormin after him? Unfortunately, I hadn't the foggiest idea. With apologies to that student, I offer this article as a belated answer.

  9. Four Steps to Fabulous Computer Furniture.

    Science.gov (United States)

    Sturgeon, Julie

    2001-01-01

    Explores how one university saved money and avoided wasted time when buying computer desks for dorm rooms. Buying considerations discussed include how the desks were to be used, the space required, desk durability, cable friendly features, and accessory necessity. (GR)

  10. Quebra da dormência da maciera (Malus domestica Borkh em São Joaquim-SC

    Directory of Open Access Journals (Sweden)

    IUCHI VERA LÚCIA

    2002-01-01

    Full Text Available A macieira é uma fruteira de clima temperado que se caracteriza pelo fenômeno de dormência das gemas, necessitando de determinado número de horas de frio (< 7,2ºC para abertura de gemas. No Brasil, São Joaquim-SC, é o local que apresenta as melhores condições climáticas para o cultivo desta espécie. Entretanto, não é correto afirmar que sempre apresenta horas de frio suficientes para satisfazer as exigências das cultivares. Foram desenvolvidos experimentos no ano 1998 e 1999, em microclimas específicos, que vão de 900 a 1400 metros de altitude, no município de São Joaquim -- SC, permitindo afirmar que apenas para a cultivar Gala, nos locais mais altos, acima de 1300 m, em anos acima de 2.300 unidades de frio, é dispensada a superação de dormência artificial.

  11. Behind the Webcam's Watchful Eye, Online Proctoring Takes Hold

    Science.gov (United States)

    Kolowich, Steve

    2013-01-01

    Hailey Schnorr has spent years peering into the bedrooms, kitchens, and dorm rooms of students via Webcam. In her job proctoring online tests for universities, she has learned to focus mainly on students' eyes. Ms. Schnorr works for ProctorU, a company hired by universities to police the integrity of their online courses. ProctorU is part of a…

  12. Superação de dormência em sementes de pau de balsa (Ochroma pyramidale

    Directory of Open Access Journals (Sweden)

    Daiane Gobes de Jesus Santos

    2016-08-01

    Full Text Available O pau de balsa (Ochroma pyramidale vem se constituindo como umas das principais espécies arbóreas no ramo de reflorestamento, devido ao seu ponto de corte rápido, que varia entre cinco e sete anos. Entretanto, as sementes desta espécie apresentam dormência devido à impermeabilidade do tegumento, dificultando a sua germinação e assim a produção de mudas. O objetivo do trabalho foi avaliar a eficiência de métodos de superação de dormência em sementes de pau de balsa. O experimento foi conduzido na Empresa de Pesquisa, Assistência e Extensão Rural (EMPAER, localizada na cidade de Guarantã do Norte, MT. Para superar a dormência as sementes foram submetidas aos seguintes tratamentos:  1 choque térmico por 10 minutos, 2 choque térmico por 15 minutos, 3 choque térmico por 20 minutos, 4 choque térmico por 25 minutos, 5 acetona por 15 minutos e 6 hipoclorito de sódio por 15 minutos. Para avaliar o efeito dos tratamentos, foram analisadas as variáveis emergência de plântulas, índice de velocidade de emergência, comprimento de parte aérea, raiz e total de plântulas. Os dados foram submetidos à análise de variância e as médias comparadas pelo teste de Skott - Knot, ao nível de 5% de probabilidade. A imersão em água quente seguida de imersão água fria (choque térmico é um tratamento eficiente na superação de dormência de sementes de pau de Balsa. O choque térmico com imersão em água quente e fria (80 ºC/ 8 ºC por 15 minutos é recomendável para superação de dormência de sementes de pau de balsa.Overcoming dormancy in pau de balsa seeds (Ochroma pyramidaleAbstract: Pau de balsa (Ochroma pyramidale has been installing as one of the principal-tree species in reforestation branch, due to its fast cut-off point, which varies between five and seven years. However, the seeds of this kind present dormancy due to the impermeability of the seed coat, hindering germination. The objective of this study was to

  13. In China, students in crowded dormitories with a low ventilation rate have more common colds: evidence for airborne transmission.

    Directory of Open Access Journals (Sweden)

    Yuexia Sun

    Full Text Available OBJECTIVE: To test whether the incidence of common colds among college students in China is associated with ventilation rates and crowdedness in dormitories. METHODS: In Phase I of the study, a cross-sectional study, 3712 students living in 1569 dorm rooms in 13 buildings responded to a questionnaire about incidence and duration of common colds in the previous 12 months. In Phase II, air temperature, relative humidity and CO(2 concentration were measured for 24 hours in 238 dorm rooms in 13 buildings, during both summer and winter. Out-to indoor air flow rates at night were calculated based on measured CO(2 concentrations. RESULTS: In Phase I, 10% of college students reported an incidence of more than 6 common colds in the previous 12 months, and 15% reported that each infection usually lasted for more than 2 weeks. Students in 6-person dorm rooms were about 2 times as likely to have an incidence of common colds ≥6 times per year and a duration ≥2 weeks, compared to students in 3-person rooms. In Phase II, 90% of the measured dorm rooms had an out-to indoor air flow rate less than the Chinese standard of 8.3 L/s per person during the heating season. There was a dose-response relationship between out-to indoor air flow rate per person in dorm rooms and the proportion of occupants with annual common cold infections ≥6 times. A mean ventilation rate of 5 L/(s•person in dorm buildings was associated with 5% of self reported common cold ≥6 times, compared to 35% at 1 L/(s•person. CONCLUSION: Crowded dormitories with low out-to indoor airflow rates are associated with more respiratory infections among college students.

  14. Quantitative assessment of bio-aerosols contamination in indoor air of University dormitory rooms.

    Science.gov (United States)

    Hayleeyesus, Samuel Fekadu; Ejeso, Amanuel; Derseh, Fikirte Aklilu

    2015-07-01

    The purpose of this study is to provide insight into how students are exposed to indoor bio-aerosols in the dormitory rooms and to figure out the major possible factors that govern the contamination levels. The Bio-aerosols concentration level of indoor air of thirty dormitory rooms of Jimma University was determined by taking 120 samples. Passive air sampling technique; the settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. The range of bio-aerosols contamination detected in the dormitory rooms was 511-9960 CFU/m(3) for bacterial and 531-6568 CFU/m(3) for fungi. Based on the criteria stated by WHO expert group, from the total 120 samples 95 of the samples were above the recommended level. The statistical analysis showed that, occupancy were significantly affected the concentrations of bacteria that were measured in all dormitory rooms at 6:00 am sampling time (p-value=0.000) and also the concentrations of bacteria that were measured in all dormitory rooms were significantly different to each other (p-value=0.013) as of their significance difference in occupancy (p-value=0.000). Moreover, there were a significant different on the contamination level of bacteria at 6:00 am and 7:00 pm sampling time (p=0.015), whereas there is no significant difference for fungi contamination level for two sampling times (p= 0.674). There is excessive bio-aerosols contaminant in indoor air of dormitory rooms of Jimma University and human occupancy produces a marked concentration increase of bacterial contamination levels and most fungi species present into the rooms air of Jimma University dormitory were not human-borne.

  15. Handling "Helicopter Parents"

    Science.gov (United States)

    Lum, Lydia

    2006-01-01

    Once upon a time, parents would help their children move into dorm rooms and apartments, then wave good-bye for the semester. Not anymore. Baby boomers have arguably been more involved in their children's educations--and their lives in general--than any preceding generation of parents, university observers say. And boomers see no reason why that…

  16. Superação de dormência em sementes de Butia capitata Overcoming dormancy in seeds of Butia capitata

    Directory of Open Access Journals (Sweden)

    Claudimar Sidnei Fior

    2011-07-01

    Full Text Available Com o objetivo de identificar métodos eficientes para a superação da dormência de sementes de B. capitata (Mart. Becc. semeadas in vitro e em germinador, foram conduzidos testes com escarificação mecânica em pré-semeadura, através da abertura parcial ou total da cavidade embrionária de sementes isoladas dos endocarpos. A abertura da cavidade embrionária acelerou significativamente a germinação, principalmente quando houve retirada total do opérculo da semente, permitindo a germinação de, em média, 90% dos embriões, independentemente da procedência dos acessos. A dormência das sementes de B. capitata parece estar relacionada com a barreira mecânica imposta pelos tecidos da semente que dificultam o desenvolvimento do embrião, o que sugere dormência exógena mecânica.Aiming to identify efficient conditions to break dormancy in Butia capitata (Mart. Becc. seeds sown in vitro and in an incubator tests were conducted with mechanical scarification in pre-sowing, by partial or total opening of the seed embryonic cavity, isolated of the endocarps. The embryonic cavity opening accelerated germination significantly, especially when there was total removal of the seed cap, allowing germination on average 90% of embryos, regardless of the provenance of the accessions. The seed dormancy of B. capitata seems to be related to the mechanical barrier imposed by the seed tissues that hamper the embryo development, suggesting mechanical exogenous dormancy.

  17. Quebra de dormência de gemas de macieira cv. Eva tratadas com cianamida hidrogenada

    Directory of Open Access Journals (Sweden)

    CRUZ JÚNIOR ÁLVARO DE OLIVEIRA

    2002-01-01

    Full Text Available A maioria das cultivares de macieiras plantadas no Brasil apresentam deficiência e desuniformidade de brotação, devido à má distribuição e/ou baixo número de horas de frio abaixo de 7,2masculine C, constituindo-se num entrave à produtividade. Mesmo utilizando-se de cultivares de baixa exigência de frio invernal, como a cultivar Eva, tem-se verificado a necessidade de se fazer a quebra de dormência para uniformizar a brotação, compatibilizar o florescimento e antecipar e melhorar a produção em regiões com invernos amenos ou anos de baixo acúmulo de frio. Avaliou-se o efeito da aplicação de cianamida hidrogenada em três diferentes concentrações (0,5; 1,0 e 1,5 % associada ao óleo mineral (3% na brotação de gemas laterais e terminais de macieiras da cv. Eva, e a fenologia das cvs. Eva e Anabela. Concluiu-se que a concentração de cianamida hidrogenada influi na percentagem de gemas laterais e terminais brotadas, sendo a concentração de 1,5% de cianamida hidrogenada associada a 3% de óleo mineral a mais efetiva na quebra da dormência das gemas

  18. Superação da dormência em sementes de Caesalpinia ferrea Mart. ex Tul. var. ferrea de duas populações

    Directory of Open Access Journals (Sweden)

    Maria de Fatima Barbosa Coelho

    2013-10-01

    Full Text Available 800x600 O objetivo no presente trabalho foi superar a dormência de sementes de Caesalpinia ferrea. As sementes foram obtidas em duas populações no município de Acarape e no distrito de Antonio Diogo no Ceará. O delineamento experimental foi em blocos casualizados com quatro tratamentos e cinco repetições de 50 sementes. Os tratamentos usados foram a sementes de Acarape intactas, b sementes de Acarape escarificadas, c sementes de Antonio Diogo intactas e d sementes de Antonio Diogo escarificadas. A escarificação foi feita com desponte com tesoura de poda no tegumento do lado oposto ao hilo da semente. As características avaliadas foram porcentagem de emergência, índice de velocidade de emergência, comprimento da parte aérea e da raiz principal das plântulas. O maior pico de emergência ocorreu aos sete dias após a semeadura. A porcentagem de emergência foi maior nas sementes de Acarape e Antonio Diogo escarificadas (58,25 e 58,50 respectivamente, enquanto as sementes não escarificadas apresentaram menos de 15% de emergência. O índice de velocidade de emergência foi maior nas sementes de Acarape e Antonio Diogo escarificadas (7,94 e 7,20 respectivamente. Os resultados comprovam a dormência tegumentar de sementes de Caesalpinia férrea, a eficiência da escarificação mecânica na superação da dormência e que há diferença no processo germinativo de sementes de diferentes populações Normal 0 21 false false false PT-BR X-NONE X-NONE

  19. Tratamentos para superação de dormência em sementes de Enterolobium contortisiliquum (Vell. Morong

    Directory of Open Access Journals (Sweden)

    Allan Deyvid Pereira da Silva

    2014-06-01

    Full Text Available 1024x768 As sementes da espécie Enterolobium contortisiliquum, popularmente conhecida como tamboril, apresentam alto grau de dormência, resultando em baixos níveis de germinação, o que dificulta a produção de mudas. Este trabalho teve como objetivo testar a eficiência da escarificação química e em água fervente para superação da dormência tegumentar das sementes de tamboril, utilizando-se os seguintes tratamentos: imersão das sementes em ácido sulfúrico (96% PA por 15, 30, 45 e 60 min, seguidos por lavagem em água corrente por 10 min; e imersão em água fervente (≅100 °C por 2, 4 min e até o resfriamento. As sementes foram colocadas para germinar em rolos de papel tipo Germitest® e incubadas em BOD, a 27 °C e fotoperíodo de 12/12 (dia e noite. Avaliou-se a porcentagem de germinação e o índice de velocidade de germinação (IVG. Os resultados permitiram inferir que a imersão das sementes em ácido sulfúrico por 15, 30, 45 e 60 min, bem como em água fervente até o resfriamento, foram os tratamentos que apresentaram maior eficiência na superação da dormência de sementes de tamboril. Todavia, recomenda-se o tratamento em água fervente até o resfriamento, levando-se em consideração a facilidade operacional e a relação custo/benefício. Normal 0 21 false false false PT-BR X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabela normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso

  20. Germinação de sementes de Stryphnodendron adstringens (Mart. Coville de diferentes origens submetidas a tratamentos para superação de dormência

    Directory of Open Access Journals (Sweden)

    Cibele Chalita Martins

    2008-12-01

    Full Text Available Sementes de diferentes procedências podem apresentar variações na intensidade de dormência, respondendo de forma diferenciada aos tratamentos e dificultando a indicação da melhor metodologia para superá-la. Este trabalho teve o objetivo de identificar métodos para superar a dormência e promover a germinação de sementes de barbatimão de diferentes procedências. Sementes dessa espécie foram colhidas em sete fragmentos de Cerrado localizados na região de Botucatu, SP, e submetidas aos seguintes tratamentos de superação de dormência: testemunha, escarificação mecânica (lixa 220, H2O quente por 20 min e escarificação com H2SO4 (95% por 40, 60 e 80 min. As sementes foram avaliadas quanto ao teor de água, teste de germinação, comprimento de plântulas, índice de velocidade de germinação e condutividade elétrica. A escarificação em ácido sulfúrico por 60 min foi o tratamento mais eficiente para superar a dormência, acelerar e aumentar a porcentagem de germinação e resultar plântulas de maior tamanho, para as sementes de diferentes locais de origem.Seeds from different sources may present variation in dormancy intensity, responding differently to treatments and making it difficult to select the best dormancy breaking method. This work aimed to identify methods for breaking dormancy and promoting germination of Stryphnodendron adstringens seeds from differents origins. Seeds of Stryphnodendron adstringens were harvested at seven cerrado fragments in the Botucatu region (SP and were submitted to the following treatments for breaking dormancy: control, mechanical scarification (with sand paper 220, boiling water for 20 minutes and acid scarification (with H2 SO4 95% for 40, 60 and 80 minutes. Seeds were evaluated by water content, germination test, seedling length, and conductivity test. Scarification with sulphuric acid for 60 minutes was the most efficient treatment for breaking dormancy, accelerating and increasing

  1. Digital substraction angiography (DSA) in a universal radiodiagnostic room with a novel multi-pulse high-frequency generator

    International Nuclear Information System (INIS)

    Ellegast, H.H.; Kloss, R.; Mayr, H.; Ammann, E.; Kuehnel, W.; Siemens A.G., Erlangen

    1985-01-01

    Application of digital subtraction angiography in a universal radiodiagnostic room can be implemented rapidly and reliably. The number of examinations could be increased without negative effects to conventional operations in this room. At optimum radiation hygiene and high-degree operational safety, the multipulse high-frequency generator with its DSA parameter automatic system guarantees a reproducibly good image quality equalling that of a special DSA facility. In this way, the examination room constitutes an economic solution for small-sized hospitals without any special angiography room, too. (orig.) [de

  2. Superação de dormência e influência da temperatura, substrato e fotoperíodo na germinação de sementes de Erythrina crista-galli L. (FABACEAE

    Directory of Open Access Journals (Sweden)

    Luciano Moura de Mello

    2016-11-01

    Full Text Available Erythrina crista-galli L. (FABACEAE é uma árvore nativa do Brasil, Uruguai, Paraguai, Bolívia e Argentina. As Regras de Análises de Sementes - RAS não possuem orientações para a realização de testes de germinação para a espécie. O objetivo deste trabalho foi testar o desempenho de tratamentos para a superação de dormência das sementes e recomendar condições adequadas de substrato, temperatura e fotoperíodo para a realização de testes de germinação. O tratamento indicado para a superação da dormência foi a escarificação mecânica e a temperatura ótima para os testes de germinação de 30ºC constantes. Não houve diferença entre tratamentos em relação aos substratos testados nem quanto aos fotoperíodos indicando-se assim o substrato entre papel e com 8h de luz por sua praticidade e economia. Superação de dormência e influência da temperatura, substrato e fotoperíodo na germinação de sementes de Erythrina crista-galli L. (FABACEAE

  3. Air, water, and surface bacterial contamination in a university-hospital autopsy room.

    Science.gov (United States)

    Maujean, Géraldine; Malicier, Daniel; Fanton, Laurent

    2012-03-01

    Today, little is known about the bacteriological environment of the autopsy room and its potential interest for medico-legal practices. Seven hundred fifty microbiological samples were taken from surface (n = 660), air (n = 48), and water (n = 42) to evaluate it in a French University Forensic Department. Median bacterial counts were compared before and during autopsy for air samples, and before and after autopsy for surface samples, using Wilcoxon matched pairs signed ranks test. Bacterial identification relied on traditional phenotypic methods. Bacterial counts in the air were low before autopsy, increased significantly during procedure, and seemed more linked to the number of people in the room than to an important production of aerosol-containing bacteria. Despite cleaning, human fecal flora was omnipresent on surfaces, which revealed insufficient disinfection. Bacteriological sampling is an easy way to monitor cleaning practices in postmortem rooms, but chiefly a way to improve the reliability of medico-legal proofs of infectious deaths. © 2012 American Academy of Forensic Sciences.

  4. A big bang in a little room the quest to create new universes

    CERN Document Server

    Merali, Zeeya

    2017-01-01

    What if you could become God, with the ability to build a whole new universe? As startling as it sounds, modern physics suggests that within the next two decades, scientists may be able to perform this seemingly divine feat-to concoct an entirely new baby universe, complete with its own physical laws, star systems, galaxies, and even intelligent life. A Big Bang in a Little Room takes the reader on a journey through the history of cosmology and unravels-particle by particle, theory by theory, and experiment by experiment-the ideas behind this provocative claim made by some of the most respected physicists alive today. Beyond simply explaining the science, A Big Bang in a Little Room also tells the story of the people who have been laboring for more than thirty years to make this seemingly impossible dream a reality. What has driven them to continue on what would seem, at first glance, to be a quixotic quest? This mind-boggling book reveals that we can nurse other worlds in the tiny confines of a lab, raising...

  5. Neutrons field in the neutronic measurements room of the Polytechnic University of Madrid

    International Nuclear Information System (INIS)

    Vega C, H. R.; Gallego, E.; Lorente, A.; Rubio O, I. P.

    2010-09-01

    Through of measurements and calculations of a Monte Carlo series has been characterized the neutronic field of the neutronic measurements room of Nuclear Engineering Department of the Polytechnic University of Madrid. The measurements were realized with the Bonner Spheres Spectrometer that allowed establish the spectra on the new stainless steel panel and at different distances measured regarding the source. The values of the speed of environmental equivalent dose were measured with an area monitor Bert hold Lb 6411. Through of Monte Carlo methods was built a detailed model of the room with the panel and the spectra were calculated and, with these the values of the environmental equivalent dose were obtained using the conversion coefficients of the ICRP 74 and the Bert hold Lb 6411 response. The calculated values were compared with those measured and was consistency among the results. (Author)

  6. Métodos de superação de dormência de sementes de barbatimão = Methods of breaking dormancy for seeds of Stryphnodendron

    Directory of Open Access Journals (Sweden)

    Cibele Chalita Martins

    2008-07-01

    Full Text Available O objetivo do trabalho foi identificar métodos para superar a dormência e promover a germinação de sementes de Stryphnodendron adstringens e Stryphnodendron polyphyllum. Sementes de ambas as espécies foram submetidas aos seguintes tratamentos desuperação de dormência: testemunha, escarificação mecânica (lixa número 220, H2O quente (temperatura inicial de 87oC por 5 e por 15 minutos, escarificação química com H2SO4 (95% por 30, 45, 60, 75, 90 e 105 minutos, choque térmico 1 (0oC e 50% UR por 1h e após imersão em água por 10 min. Ti=85oC Tf=57oC, choque térmico 2 (40oC e 40%UR por 6 h e após imersão em água por 10 min. Ti=0oC Tf=3oC, choque térmico 3 (40oC e 40% UR por 6h e após imersão em água por 10 min Ti=25oC Tf=25oC. Conclui-se que sementes pertencentes ao mesmo gênero, mas de espécies diferentes, respondem de forma diversa a alguns tratamentos de superação de dormência. Para ambas as espécies, a escarificação das sementes com H2SO4 (45 minutos ou lixa são métodos que podem ser utilizados com máxima eficiência para a superação da dormência e promoção da germinação.The aim of this research was to identify methods for breaking dormancy and promoting germination of Stryphnodendron adstringens and S. polyphyllum seeds. Seeds of both species were submitted to the following treatments for breaking dormancy: control; mechanical scarification (sandpaper number 220; hot water (initial temperature of 87°C for 5 and 15 minutes; chemical scarification with H2SO4 (95% for 30, 45, 60, 75, 90 and 105 minutes; thermalshock 1 (0°C and 50% RH for 1 h and thereafter 10 minutes into water Ti=85°C, Tf=57°C; thermic shock 2 (40°C and 40% RH for 6 h and thereafter 10 minutes into water, Ti=0°C, Tf=3°C; thermal shock 3 (40°C and 40% RH for 6h and thereafter 10 minutes into water, Ti=25°C, Tf=25°C. We concluded that seeds belonging to samegenus but from different species answered differently to some treatments

  7. Shuffled Cards, Messy Desks, and Disorderly Dorm Rooms - Examples of Entropy Increase? Nonsense!

    Science.gov (United States)

    Lambert, Frank L.

    1999-10-01

    The order of presentation in this article is unusual; its conclusion is first. This is done because the title entails text and lecture examples so familiar to all teachers that most may find a preliminary discussion redundant. Conclusion The dealer shuffling cards in Monte Carlo or Las Vegas, the professor who mixes the papers and books on a desk, the student who tosses clothing about his or her room, the fuel for the huge cranes and trucks that would be necessary to move the nonbonded stones of the Great Pyramid of Cheops all across Egypteach undergoes physical, thermodynamic entropy increase in these specific processes. The thermodynamic entropy change from human-defined order to disorder in the giant Egyptian stones themselves, in the clothing and books in a room or papers on a desk, and in the millions of cards in the world's casinos is precisely the same: Zero. K. G. Denbigh succinctly summarizes the case against identifying changes in position in one macro object or in a group with physical entropy change (1): If one wishes to substantiate a claim or a guess that some particular process involves a change of thermodynamic or statistical entropy, one should ask oneself whether there exists a reversible heat effect, or a change in the number of accessible energy eigenstates, pertaining to the process in question. If not, there has been no change of physical entropy (even though there may have been some change in our "information"). Thus, simply changing the location of everyday macro objects from an arrangement that we commonly judge as orderly (relatively singular) to one that appears disorderly (relatively probable) is a "zero change" in the thermodynamic entropy of the objects because the number of accessible energetic microstates in any of them has not been changed. Finally, although it may appear obvious, a collection of ordinary macro things does not constitute a thermodynamic system as does a group of microparticles. The crucial difference is that such

  8. Improving operating room safety

    Directory of Open Access Journals (Sweden)

    Garrett Jill

    2009-11-01

    Full Text Available Abstract Despite the introduction of the Universal Protocol, patient safety in surgery remains a daily challenge in the operating room. This present study describes one community health system's efforts to improve operating room safety through human factors training and ultimately the development of a surgical checklist. Using a combination of formal training, local studies documenting operating room safety issues and peer to peer mentoring we were able to substantially change the culture of our operating room. Our efforts have prepared us for successfully implementing a standardized checklist to improve operating room safety throughout our entire system. Based on these findings we recommend a multimodal approach to improving operating room safety.

  9. The changing sensory room

    DEFF Research Database (Denmark)

    2018-01-01

    In 2017 the kindergarten The Milky Way in the city Vejle in Denmark made a sensory room that has the special ability change whenever wanted by the children and social educators. Kjetil Sandvik (to the right) from Copenhagen University and Klaus Thestrup from Aarhus University reflects upon what...... they saw, took part in and talked with the social educators about. Jacob Knudsen from VIFIN filmed the two gentlemen and organised the project. it is a room composed around common experiments, many self-made objects, open narrative structures. and a combination of digital and analogue elements....

  10. A STUDY OF PRE OPERATION NURSING VISIT ABOUT THE NURSES’ VIEW FROM THE SURGERY ROOM OF A UNIVERSITY HOSPITAL.

    Directory of Open Access Journals (Sweden)

    Izilda Esmenia Muglia Araújo

    2004-08-01

    Full Text Available This study to do an analysis of the PONV`s importance, by nurses from the Daily’s SurgeryRoom of an University Hospital, through forms distributed to them and to apply the written communicationinstrument on the PONV,proposed by NORONHA & ARAÚJO (1995. The results this research were: 92,9% ofthe nurses from the Daily’s Surgery Room think that it is important the performance of the PONV to the patientand Nursing aid, and 85,7% think the PONV is important for the nurse who works in a Surgery Room. Thewritten communication instrument on the PONV was applied with success, being really easy to fill it in with clearquestions , showing so to be a lot of viable but some items of the instrument like blood group and FATOR RHcouldn’t be filled even after the records check. In this way, I think it is worth the suggestion o9f sitting the writtencommunication instrument proposed by ARAÚJO AND NORONHA (1995 at this State University, proposinghowever, inclusion on the patients’ records data about blood group and FATOR RH.

  11. Genetic control of seed dormancy and pre-harvest sprouting in wheat Controle genético da dormência e da germinação precoce em trigo

    Directory of Open Access Journals (Sweden)

    Claudinei Andreoli

    2006-12-01

    Full Text Available Pre-harvest sprouting (PHS damage leads to occasional massive losses in all wheat producing areas, causing downgrading of grain quality, that severely limits end-use applications and results in substantial financial losses to farmers and food processors. Red grain color is a traditional marker for resistance to sprouting in wheat breeding programs, however red-grained genotype alone does not always guarantee effective resistance. The objective of this work was to find genes for resistance to PHS and investigate its inheritance in Brazilian wheat cultivars. Genetic variation for dormancy was investigated in the parents, F1 and 300 F2 lines derived from the cross Frontana × OR1 and its reciprocal. The germination/dormancy sprouted grains was evaluated on fifty seeds per replication, germinated in paper towel rolls at 20ºC for 5 days. A bimodal distribution for dormancy occurred in the Frontana/OR1 and OR1/Frontana derived F2 populations. The mean ratio of dormant and non-dormant seeds of the cross and its reciprocal was 85:1115, fitting a digenic model of 1:15 (P Germinação precoce na espiga (PHS ocasiona perdas significativas nas regiões produtoras de trigo, causando depreciação na qualidade do produto final, o que resulta em prejuízos para os produtores e os moageiros. A cor vermelha do grão é um marcador tradicional para resistência à germinação nos programas de melhoramento de trigo, todavia, o genótipo de grão vermelho sózinho não garante resistência efetiva. O objetivo desse trabalho foi encontrar gene(s para resistência à PHS e estudar a herança do caráter dormência de semente nos cultivares de trigo brasileiro. A variação genética para dormência foi investigada nos parentais, no F1 e em 300 linhas F2 derivadas do cruzamento de Frontana × OR1, e o cruzamento recíproco. Os grãos brotados (sprouted e os dormentes foram avaliados pelo teste de germinação, em rolo de papel, a 20º C por 5 dias. Observou-se uma

  12. Métodos para superação da dormência de sementes de quixabeira (Sideroxylon obtusifolium (Roem. & Schult. T.D.Penn..

    Directory of Open Access Journals (Sweden)

    Ana Clara Moura Neves Rebouças

    2012-03-01

    Full Text Available http://dx.doi.org/10.5902/198050985090Devido à ausência de informações sobre a metodologia para avaliação da qualidade fisiológica de sementes das espécies arbóreas medicinais, o presente trabalho teve por objetivo determinar o método mais eficiente para superação da dormência tegumentar em sementes de Sideroxylon obtusifolium (Roem. & Schult. T.D.Penn.. Além das sementes intactas, sementes que não foram submetidas a nenhum tratamento, também foram utilizados os seguintes tratamentos pré-germinativos: escarificação química - as sementes foram imersas em ácido sulfúrico absoluto por 10, 20, 30, 40, 50 e 60 minutos; escarificação mecânica - as sementes foram friccionadas manualmente em lixa nº 50, do lado oposto à micrópila, sem ou com embebição por 24 ou 48 horas; imersão em água a 100ºC por 15 ou 30 segundos; imersão em água a 80ºC até o resfriamento. Os efeitos foram avaliados através de testes de germinação e vigor. Constatou-se que houve diferença significativa entre os tratamentos para todos os parâmetros avaliados (porcentagem e velocidade de germinação, comprimento e massa seca de parte aérea e raiz primária, e a causa mais evidente da dormência é a impermeabilidade do tegumento, a qual foi superada com maior eficiência pelo método de imersão em ácido sulfúrico por 30 minutos.

  13. Superação da dormência em sementes de crista de galo Overcoming of dormancy of crista de galo in seeds

    Directory of Open Access Journals (Sweden)

    Elane Grazielle Borba de Sousa Ferreira

    2012-05-01

    Full Text Available O presente trabalho teve como objetivo avaliar o efeito de diferentes tratamentos pré-germinativos na superação da dormência de sementes de Celosia cristata L., que foram submetidas aos seguintes tratamentos: choque térmico - exposição em estufa a 80°C por 5 minutos, escarificação química com ácido sulfúrico por um minuto, 30 segundos e 5 minutos, imersão das sementes intactas em água a 80°C até resfriamento, imersão das sementes intactas em água à temperatura ambiente por 24 horas e a testemunha - sem tratamento. Na avaliação do efeito dos tratamentos, foram determinados a porcentagem final, primeira contagem e índice de velocidade de germinação, como também o comprimento da raiz e do hipocótilo. As sementes de C. cristata L. quando oriundas de frutos maduros não necessitam da utilização de tratamentos para superação da dormência.This study had the objective of evaluating the effect of different pre-germination treatments for overcome of dormancy of Celosia cristata seeds, subjected to the following treatments: heat shock - exhibition in an oven at 80°C for 5 minutes, chemical scarification with sulfuric acid for 1 minute, 30 seconds and 5 minutes, immersion of intact seeds in water the 80°C at cooling and immersion of intact seeds in water for 24 hours, and the control - no treatment. We evaluated the following final percentage, first count and germination speed index, but also the length of the primary root and hypocotyl. The seeds of C. cristata when coming from ripe fruits do not require the use of treatments to overcoming dormancy.

  14. Dinâmica da dormência de gemas de videira e quivizeiro em região de baixa ocorrência de frio

    Directory of Open Access Journals (Sweden)

    Luiz Antonio Biasi

    2010-12-01

    Full Text Available O objetivo desta pesquisa foi determinar a dinâmica da dormência de gemas de videira cv. Niagara Branca e de quivizeiro cv. Bruno, em região de baixa ocorrência de frio. Os experimentos foram realizados nos anos de 2007 e 2008, com coletas de ramos a cada duas semanas, em pomares localizados em Pinhais-PR. Na última coleta, um grupo adicional de ramos foi coletado e mantido em refrigerador a temperatura de 4 a 7º C, por 1.440 horas. A avaliação da dormência foi realizada por meio do teste biológico de estacas de nós isolados em sala de crescimento, à temperatura de 25º C e fotoperíodo de 16 horas. Foi realizada a quantificação de horas de frio (HF e de unidades de frio (UF ocorridas na região. As duas espécies foram avaliadas como experimentos distintos. O delineamento experimental adotado foi o completamente casualizado, com doze tratamentos em 2007 e onze tratamentos em 2008, ambos com quatro repetições e dez estacas por unidade experimental. A endodormência de gemas de quivizeiro 'Bruno' instala-se a partir de abril e atinge maior intensidade do final de maio à segunda metade de junho. A saída da endodormência pode ocorrer naturalmente até o fim de agosto, mas com variações entre os anos. A endodormência de gemas de videira 'Niagara Branca' instala-se em abril e mantém-se intensa até maio. A saída natural da endodormência ocorre da metade de agosto ao início de setembro.

  15. New heuristics for planning operating rooms.

    NARCIS (Netherlands)

    Molina-Pariente, J.M.; Hans, Elias W.; Framinan, J.M.; Gomez-Cia, T.

    2015-01-01

    We tackle the operating room planning problem of the Plastic Surgery and Major Burns Specialty of the University Hospital “Virgen del Rocio” in Seville (Spain). The decision problem is to assign an intervention date and an operating room to a set of surgeries on the waiting list, minimizing access

  16. The Ethics of the Collegiate Locker Room

    Science.gov (United States)

    Roper, Larry D.

    2017-01-01

    Locker rooms are a fixture in the athletic culture of colleges and universities. Given the important roles those spaces play in the learning, growth, and development of student-athletes, collegiate leaders should consider how to influence locker room environments in positive ways.

  17. Department of Defense Annual Report on Sexual Assault in the Military. Fiscal Year 2013

    Science.gov (United States)

    2014-04-16

    while intoxicated at a bar during Cinco de Mayo festivities . Victim reported she was walking up the stairs toward a bathroom when USN Subject was...to recommend action on the charges preferred. Victim reported that she invited Subject to listen to music in her dorm room. Victim stated that

  18. Storage and methods for overcoming dormancy of the coral tree seedsArmazenamento e métodos para a superação da dormência de sementes de mulungu

    Directory of Open Access Journals (Sweden)

    Ana Claudia da Silva

    2013-03-01

    dificultado pela ocorrência de dormência tegumentar nas sementes. Assim, o objetivo do presente trabalho foi avaliar o efeito de diferentes métodos para superar a dormência em sementes de mulungu armazenadas em diferentes condições e períodos. O delineamento experimental foi inteiramente casualizado em esquema fatorial 5 x 2 (métodos para superar a dormência e tipos de armazenamento, em quatro repetições de 25 sementes. Os métodos foram (S1 testemunha; (S2 sementes escarificadas do lado oposto à micrópila; (S3 sementes escarificadas junto à micrópila; (S4 sementes imersas em água a 80 °C por cinco minutos e (S5 sementes imersas em água a 100 ºC por dois minutos. Os tipos de armazenamento foram por 25 meses em câmara fria e por um mês em ambiente do Laboratório. As características avaliadas foram porcentagem de emergência de plântulas (PE, tempo médio de emergência (TM, comprimento da parte aérea (CPA e da raiz (CR, diâmetro do colo (D, número de folhas (NF, biomassa seca das raízes (MSR e parte aérea das plântulas (MSPA. A porcentagem de emergência foi baixa nos tratamentos S1, S4 e S5 e as sementes armazenadas por apenas um mês foram mais afetadas quando imersas em água quente. Os maiores valores de CPA, CR, MSPA e NF foram observados nos tratamentos S2 e S3, nos quais ocorreu o menor tempo médio de emergência de plântulas. A dormência tegumentar das sementes de Erythrina velutina é superada com escarificação em lixa na extremidade oposta à micrópila ou junto à mesma. A dormência não é afetada pelos tipos de armazenamento e não é superada pela imersão em água quente.

  19. 6 June 2008 - Chancellor F. Tomàs Vert, University of Valencia, visiting ATLAS control room and experimental area with Collaboration Spokesperson P. Jenni.

    CERN Multimedia

    Mona Schweizer

    2008-01-01

    6 June 2008 - Chancellor F. Tomàs Vert, University of Valencia, visiting ATLAS control room and experimental area with Collaboration Spokesperson P. Jenni. Other participants: Prof. Francisco José Botella, Director, Instituto de Fisica Corpuscular, University of València and CSIC Prof. José Peñarrocha, Dean, Faculty of Physics Prof. Antonio Ferrer, Instituto de Fisica Corpuscular, University of València and CSIC Prof. Antonio Pich, University of València, Member of IFIC (CSIC - Univ. València), Coordinator of CPAN, Spanish National Centre for Particle, Astroparticle and Nuclear Physics.

  20. Superação de dormência de maracujá-do-mato (Passiflora cincinnata Mast. Overcoming dormancy seeds of passion fruit (Passiflora cincinnata mast.

    Directory of Open Access Journals (Sweden)

    Manoel Xavier de Oliveira Júnior

    2010-06-01

    Full Text Available Com o objetivo de avaliar métodos de superação de dormência em sementes de maracujá-do-mato (P. cincinnata Mast., foi conduzido o experimento em casa de vegetação, na Universidade Estadual do Sudoeste do Estado da Bahia - UESB, Câmpus de Vitória da Conquista - BA, Brasil. O delineamento experimental foi o inteiramente casualizado, com sete tratamentos e três repetições, sendo 50 sementes por parcela: T1= sementes secas à sombra (Testemunha; T2= sementes secas ao sol (35 ±1ºC; T3= sementes secas à sombra com escarificação em lixa; T4= sementes secas à sombra tratadas com captana (0,2%; T5= sementes secas ao sol (35 ±1ºC com escarificação em lixa; T6= sementes secas à sombra aquecidas em banho-maria por 5 minutos, a 50ºC; T7= sementes secas à sombra aquecidas em banho-maria por 5 minutos, a 80ºC. As características avaliadas foram: porcentagem de germinação; porcentagem de emergência; índice de velocidade de emergência; altura das plântulas; diâmetro do caule; número de folhas; comprimento da raiz pivotante; massa da matéria seca total. Os resultados obtidos e analisados permitiram concluir que os melhores tratamentos para superação de dormência são o T3 (sementes secas à sombra com escarificação em lixa e T6 (sementes secas à sombra aquecidas em banho-maria por 5 minutos, a 50ºC.With the objective of evaluating the effect of different methods of dormancy break down on P.cincinnata Mast. seeds, a research was carried out in greenhouse at Bahia State University, Campus of Vitória da Conquista county, Bahia State, Brazil. The experimental design was a interely randomized blocks, composed of seven treatments and three replications, (T1-seeds dried in shade; T2-seeds dried in the sun; T3-seeds dried in shade followed by scarification; T4-seeds dried in shade and treated with captana (0,2%; T5-seeds dried in the sun followed by scarification; T6-seeds dried in shade and treated with hot water at 50ºC; T7

  1. The Labours of Hercules: Ethical Embodiment and an Erasmian Justification for Higher Education

    Science.gov (United States)

    De Barros, Eric L.

    2014-01-01

    In the early 1990s, a popular American dorm-room poster luminously asserted crass materialism as "JUSTIFICATION FOR HIGHER EDUCATION". Self-consciously premised on the paradoxical success of my failure or failure of my success as a professor of Renaissance literature and culture, this essay draws on Erasmus's educational theory of…

  2. Intraoperative and recovery room outcome | Edomwonyi | East ...

    African Journals Online (AJOL)

    Objectives: To identify and quantitate anaesthesia related complications in the intraoperative period and in the post anaesthesia recovery room. Design: A prospective study. Setting: University of Benin Teaching Hospital; a University - affiliated tertiary centre. Subjects: Patients scheduled for elective and emergency surgery ...

  3. Condições de armazenamento na viabilidade e dormência de sementes de videira Effect of storage conditions on the viability and dormancy of grape seeds

    Directory of Open Access Journals (Sweden)

    Jocely Andreuccetti Maeda

    1985-01-01

    Full Text Available A manutenção da viabilidade de sementes por períodos mais ou menos longos está bastante relacionada com as condições em que elas são armazenadas. Temperatura e teor de umidade estão entre os fatores que mais afetam sua longevidade. O objetivo deste trabalho é o estudo da viabilidade e dormência de uva do cultivar Patrícia, armazenada durante 24 meses em dois tipos de recipientes - em vidro hermético e saco de papel - a temperaturas de 10, 20 e 30°C, com dois diferentes teores iniciais de umidade. A porcentagem de sementes dormentes e viáveis foi determinada bimestralmente durante os primeiros 12 meses, e semestralmente nos períodos mais longos. O armazenamento não quebrou a dormência das sementes de uva em nenhuma das condições estudadas. Enquanto as sementes frescas mostraram melhor conservação a 10°C quando embaladas em vidro hermético, sementes secas se conservaram melhor a 20°C. Em saco de papel, foram poucas as diferenças encontradas entre os tratamentos, a não ser nos períodos finais do armazenamento, quando 20°C se mostrou a pior temperatura de conservação. Dessa maneira, a dormência não foi alterada pelo armazenamento, nas condições estudadas, e a viabilidade foi bastante afetada tanto pelo tipo de embalagem como pela temperatura de armazenamento.Longevity of seeds is affected by the storage conditions, being temperature and seed moisture content the major factors to keep seeds viable. Experiments described here are concerned to the study of dormancy ant viability of seeds of grape cv. Patrícia, stored with two different moisture contents, either in moisture proof containers or paper bags, at temperaturss of 10°C, 20°C and 30°C, for 24 months. Samples were taken every two months during the first 12 months and at 6 months intervals in the second year, to determine seed viability and dormancy level. Storage, in the studied conditions, did not alter dormancy levei of the seeds. When stored in hermetical

  4. Cultural differences in room size perception.

    Science.gov (United States)

    Saulton, Aurelie; Bülthoff, Heinrich H; de la Rosa, Stephan; Dodds, Trevor J

    2017-01-01

    Cultural differences in spatial perception have been little investigated, which gives rise to the impression that spatial cognitive processes might be universal. Contrary to this idea, we demonstrate cultural differences in spatial volume perception of computer generated rooms between Germans and South Koreans. We used a psychophysical task in which participants had to judge whether a rectangular room was larger or smaller than a square room of reference. We systematically varied the room rectangularity (depth to width aspect ratio) and the viewpoint (middle of the short wall vs. long wall) from which the room was viewed. South Koreans were significantly less biased by room rectangularity and viewpoint than their German counterparts. These results are in line with previous notions of general cognitive processing strategies being more context dependent in East Asian societies than Western ones. We point to the necessity of considering culturally-specific cognitive processing strategies in visual spatial cognition research.

  5. Cultural differences in room size perception.

    Directory of Open Access Journals (Sweden)

    Aurelie Saulton

    Full Text Available Cultural differences in spatial perception have been little investigated, which gives rise to the impression that spatial cognitive processes might be universal. Contrary to this idea, we demonstrate cultural differences in spatial volume perception of computer generated rooms between Germans and South Koreans. We used a psychophysical task in which participants had to judge whether a rectangular room was larger or smaller than a square room of reference. We systematically varied the room rectangularity (depth to width aspect ratio and the viewpoint (middle of the short wall vs. long wall from which the room was viewed. South Koreans were significantly less biased by room rectangularity and viewpoint than their German counterparts. These results are in line with previous notions of general cognitive processing strategies being more context dependent in East Asian societies than Western ones. We point to the necessity of considering culturally-specific cognitive processing strategies in visual spatial cognition research.

  6. Superação de dormência de sementes como estratégia para restauração florestal de pastagem tropical Seed dormancy overcoming as a strategy for forest restoration in tropical pasture

    Directory of Open Access Journals (Sweden)

    Silvia Rahe Pereira

    2013-02-01

    Full Text Available O objetivo deste trabalho foi avaliar a influência de tratamentos de superação da dormência de sementes sobre a taxa e o tempo de emergência de espécies arbóreas de Fabaceae, e sobre seu estabelecimento, quando reintroduzidas em pastagem, no Cerrado. Foram realizados experimentos em casa de vegetação e em campo (pastagem de Urochloa brizantha, com as espécies Mimosa caesalpiniifolia, Peltophorum dubium, Pterogyne nitens, Dimorphandra mollis, Copaifera langsdorffii e Hymenaea stigonocarpa, submetidas ou não aos seguintes tratamentos de superação de dormência: D. mollis e H. stigonocarpa, escarificação mecânica; C. langsdorffii e M. caesalpiniifolia, escarificação química com H2SO4; P. nitens, punção do tegumento; e P. dubium, imersão em água a 80ºC. O estabelecimento em campo foi monitorado por 21 meses. A superação de dormência promoveu, em casa de vegetação, maior emergência de quatro das seis espécies avaliadas, e, no campo, de cinco espécies. Além disso, reduziu o tempo de emergência das espécies e aumentou o recrutamento de M. caesalpiniifolia, P. nitens, D. mollis e H. stigonocarpa, aos 127 dias, e de H. stigonocarpa aos 659 dias. Os tratamentos de superação de dormência podem aumentar a eficiência da semeadura direta, em projetos de restauração de áreas degradadas no Cerrado, ao promover maior emergência das sementes e o estabelecimento das plantas.The objective of this work was to evaluate the influence of seed dormancy overcoming treatments on the rate and time of emergence of Fabaceae tree species, and on their recruitment when reintroduced in a tropical pasture, in the Brazilian Cerrado. Experiments were carried out in greenhouse and field (Urochloa brizantha pasture, with the species Mimosa caesalpiniifolia, Peltophorum dubium, Pterogyne nitens, Dimorphandra mollis, Copaifera langsdorffii and Hymenaea stigonocarpa, subjected or not to the following treatments of dormancy break: D. mollis and

  7. Control room lay-out

    International Nuclear Information System (INIS)

    Toma, Violeta

    2004-01-01

    TRIUMF (Tri-University Meson Facility) is Canada's national laboratory for particle and nuclear physics. There are 6 accelerators and 3 Control Rooms at TRIUMF. The main control room serves the big cyclotron, the 500 MeV, and the adjacent experiment. The 42 MeV and two 32 MeV ones are production dedicated. These cyclotrons belong to a private company but are operated by TRIUMF staff from ATG (Applied Technology Group) Control Room. The last is ISAC (Isotope Acceleration and Separation) Control Room, from which the LINAC is controlled. Research areas cover theoretical (2 subjects), pure (5 subjects) and applied (8 subjects) physics. In the early '70s, as the 500 MeV was being completed, the first Control Room was built in the main accelerator building. The recent topics covered by this paper are proton and pion therapy, what are the operator's duties?, the CP42, TR30 and TR13 cyclotron control rooms, the ISAC control systems including control room modification. Due to the nature of an operator's job, the Control Room layout is pretty important. This is true for any work environment, but when working shifts it becomes essential. Lots of time and effort, not to mention money, were spent to figure out the optimum configuration. It seems to me that the key factor in the control room layout is versatility, and this is because it has to keep happy a group of people with different inclinations, which have a tendency to become quite moody after the second night shift. No matter what, there will still be unhappy people, but we are trying our best. (Y. Tanaka)

  8. Assessment of Clinical Stressful Factors Among Academic Students of Nursing and Operating Room of Dezful University of Medical Sciences (2015

    Directory of Open Access Journals (Sweden)

    Mojtaba Raji

    2016-07-01

    Full Text Available Background and Objective: Nursing students are exposed to clinical environmental stresses in addition to educational environmental stresses. The aim of this study was to assessment of clinical stressful factors among Academic Students of Nursing and Operating Room of Dezful University of Medical Sciences in 2015.Materials and Methods: This study was a description-analytical study with 234 students of nursing and operation room up to two semesters for enrolled. Data was using a self-made researcher Questionnaire consisted of demographic information and clinical stressful factors. Data analysis was performed by descriptive and inferential statistics using SPSS-PC (v.20.Results: The findings showed that the main stressors in students of nursing and operation room were unpleasant emotions and least stressful areas were interpersonal communication in a clinical environment. The results showed that the average score of the field of education and humiliating experiences using Spearman correlation test (P=0/045 (r=0/16.Conclusion: Study showed, the mean stress is the moderate level. Stressful areas obtained in the four areas of personal communication, clinical practice stressful, unpleasant feelings and humiliating experience that fortunately, in many cases reform and change.

  9. Towards Universal Design Hotels in Denmark.

    Science.gov (United States)

    Grangaard, Sidse

    2016-01-01

    Based on the research project 'Accessible Hotel Rooms' that studies the balance between the experience of supply and demand regarding accessibility features in Danish hotel rooms, this paper demonstrates factors having an influence on Universal Design hotels in Denmark. The research project was financed by the Danish Transport and Construction Agency. Different notions in the hotel sector of the current supply and demand for Universal Design hotel rooms are identified, as well as future demand. Despite supplying accessible rooms, some hotels do not advertise their accessibility features on their website. There exists an attitude in the hotel sector that functions as a barrier for Universal Design: if there are enough guests, for example business travellers, then why market the hotel on Universal Design? The paper points out the coherence between the understanding of the users and the view of demand. Another important factor is Corporate Social Responsibility, which can be regarded as a strategy or platform towards Universal Design hotels.

  10. Mass concentration and elemental composition of indoor PM 2.5 and PM 10 in University rooms in Thessaloniki, northern Greece

    Science.gov (United States)

    Gemenetzis, Panagiotis; Moussas, Panagiotis; Arditsoglou, Anastasia; Samara, Constantini

    The mass concentration and the elemental composition of PM 2.5 and PM 10 were measured in 40 rooms (mainly offices or mixed office-lab rooms, and photocopying places) of the Aristotle University of Thessaloniki, northern Greece. A total of 27 major, minor and trace elements were determined by ED-XRF analysis. The PM 2.5/PM 10 concentration ratios averaged 0.8±0.2, while the corresponding elemental ratios ranged between 0.4±0.2 and 0.9±0.2. The concentrations of PM 2.5 and PM 10 were significantly higher (by 70% and 50%, respectively) in the smokers' rooms compared to the non-smokers' places. The total elemental concentrations were also higher in the smokers' rooms (11.5 vs 8.2 μg m -3 for PM 2.5, and 10.3 vs 7.6 μg m -3 for PM 2.5-10). Fine particle concentrations (PM 2.5) were found to be quite proportional to smoking strength. On the contrary, the two environments exhibited similar coarse (PM 2.5-10) particle fractions not related to the number of cigarettes smoked. A slight decrease of particle concentrations with increasing the floor level was also observed, particularly for PM 2.5, suggesting that high-level floors are less impacted by near ground-level sources like traffic emissions. Finally, the removal efficiency of air purification systems was evaluated.

  11. AHP 28: The Price of a Thesis

    Directory of Open Access Journals (Sweden)

    Pad+ma skyabs པདྨ་སྐྱབས།

    2013-12-01

    Full Text Available "Ring…ring…" bleated a mobile phone, waking Lha mo, a student in the Tibetan Department at a well-known nationalities university. She raised her head languidly and looked around the dorm room. Her roommates were applying various cosmetics and lotions to their faces, getting ready for class. The warm sun heated her bed. She slowly turned her head to the right and gazed at a small picture of a young Chinese movie star pasted on the wall by her bed. He was wearing a shirt that exposed his skin, which seemed as white as flour smeared on a cutting board beneath a ball of dough. Nearby was a panda doll wearing a suit of red clothes that made it resemble a sleeping guard. She was suddenly overwhelmed by nostalgia. ...

  12. Superação da dormência e avaliação da qualidade fisiológica de sementes de Sesbania virgata Dormancy break and evaluation of physiological quality of Sesbania virgata seeds

    Directory of Open Access Journals (Sweden)

    Valquíria Nogueira Camargos

    2008-12-01

    Full Text Available A avaliação da qualidade fisiológica de lotes de sementes de Sesbania virgata é dificultada pela dormência inerente à espécie, bem como pela inadequação metodológica de testes disponíveis. Para desenvolver procedimentos adequados à avaliação da qualidade das sementes de S. virgata, foram avaliados métodos tanto para quebra de dormência como para realização do teste de tetrazólio. Em uma primeira fase, as sementes de cinco lotes foram submetidas a tratamentos para quebra de dormência: lixa, ácido e corte do tegumento, previamente ao teste de germinação. Para caracterização dos lotes e adequação da metodologia do teste de tetrazólio, na segunda fase, as sementes foram lixadas na região oposta ao eixo embrionário, e submetidas aos seguintes testes: tetrazólio, germinação, velocidade de emergência, peso de matéria fresca e de matéria seca de plântulas. Foram utilizados dois métodos de pré-condicionamento: embebição em papel por 18 h a 30 ºC e imersão em água por 12 h a 30 ºC e três períodos (uma, duas e três horas de imersão em solução de tetrazólio 0,5%. Na análise do perfil dos lotes de S. virgata foram detectadas variações na qualidade fisiológica pelos resultados dos testes de vigor e germinação. O método de escarificação com lixa possibilitou a quebra de dormência das sementes de S. virgata,e o pré-condicionamento das sementes em papel com embebição em solução de tetrazólio 0,5% por duas horas é um procedimento adequado para avaliação da viabilidade das sementes.The evaluation of Sesbania virgata seed physiological quality is hampered by its intrinsic seed dormancy and inadequate methodologies among available tests. To develop an adequate procedure to evaluate S. virgata seed quality, methods for dormancy breaking and tetrazolium test accomplishment were evaluated. In a first stage, seeds from five lots were submitted to dormancy breaking methods: sandpaper, acid and

  13. Indoor air bacterial load and antibiotic susceptibility pattern of isolates in operating rooms and surgical wards at jimma university specialized hospital, southwest ethiopia.

    Science.gov (United States)

    Genet, Chalachew; Kibru, Gebre; Tsegaye, Wondewosen

    2011-03-01

    Surgical site infection is the second most common health care associated infection. One of the risk factors for such infection is bacterial contamination of operating rooms' and surgical wards' indoor air. In view of that, the microbiological quality of air can be considered as a mirror of the hygienic condition of these rooms. Thus, the objective of this study was to determine the bacterial load and antibiotic susceptibility pattern of isolates in operating rooms' and surgical wards' indoor air of Jimma University Specialized Hospital. A cross sectional study was conducted to measure indoor air microbial quality of operating rooms and surgical wards from October to January 2009/2010 on 108 indoor air samples collected in twelve rounds using purposive sampling technique by Settle Plate Method (Passive Air Sampling following 1/1/1 Schedule). Sample processing and antimicrobial susceptibility testing were done following standard bacteriological techniques. The data was analyzed using SPSS version 16 and interpreted according to scientifically determined baseline values initially suggested by Fisher. The mean aerobic colony counts obtained in OR-1(46cfu/hr) and OR-2(28cfu/hr) was far beyond the set 5-8cfu/hr acceptable standards for passive room. Similarly the highest mean aerobic colony counts of 465cfu/hr and 461cfu/hr were observed in Female room-1 and room-2 respectively when compared to the acceptable range of 250-450cfu/hr. In this study only 3 isolates of S. pyogenes and 48 isolates of S. aureus were identified. Over 66% of S. aureus was identified in Critical Zone of Operating rooms. All isolates of S. aureus showed 100% and 82.8% resistance to methicillin and ampicillin respectively. Higher degree of aerobic bacterial load was measured from operating rooms' and surgical wards' indoor air. Reducing foot trafficking, improving the ventilation system and routine cleaning has to be made to maintain the aerobic bacteria load with in optimal level.

  14. Planets in a Room

    Science.gov (United States)

    Giacomini, l.; Aloisi, F.; De Angelis, I.

    2017-09-01

    Teaching planetary science using a spherical projector to show the planets' surfaces is a very effective but usually very expensive idea. Whatsmore, it usually assumes the availability of a dedicated space and a trained user. "Planets in a room" is a prototypal low cost version of a small, spherical projector that teachers, museum, planetary scientists and other individuals can easily build and use on their own, to show and teach the planets The project of "Planets in a Room" was made by the italian non-profit association Speak Science with the collaboration of INAF-IAPS of Rome and the Roma Tre University (Dipartimento di Matematica e Fisica). This proposal was funded by the Europlanet Outreach Funding Scheme in 2016. "Planets in a room" will be presented during EPSC 2017 to give birth to the second phase of the project, when the outreach and research community will be involved and schools from all over Europe will be invited to participate with the aim of bringing planetary science to a larger audience.

  15. Electroacoustical simulation of listening room acoustics for project ARCHIMEDES

    DEFF Research Database (Denmark)

    Bech, Søren

    1989-01-01

    ARCHIMEDES is a psychoacoustics research project, funded under the European EUREKA scheme. Three partners share the work involved: The Acoustics Laboratory of The Technical University of Denmark; Bang and Olufsen of Denmark; and KEF Electronics of England. Its primary object is to quantify...... the influence of listening room acoustics on the timbre of reproduced sound. For simulation of the acoustics of a standard listening room, an electroacoustic setup has been built in an anechoic chamber. The setup is based on a computer model of the listening room, and it consists of a number of loudspeakers...

  16. Tecnologia alternativa para a quebra de dormência das sementes de pau-de-balsa (Ochroma lagopus Sw., Bombacaceae Alternative technology for breaking dormancy of balsa wood (Ochroma lagopus Sw., Bombacaceae seeds

    Directory of Open Access Journals (Sweden)

    Antenor P. Barbosa

    2004-01-01

    Full Text Available Este trabalho, teve como objetivo estudar a germinação das sementes de pau-de-balsa (Ochroma lagopus Sw., Bombacaceae em diferentes estágios de maturação aparente dos frutos; a germinação das sementes provenientes de árvores com diferentes diâmetros a altura do peito (DAP e a germinação das sementes tratadas para quebra de dormência. No primeiro experimento, avaliou-se a germinação das sementes dos frutos verdes, verdosos (verde amarelado, negros (fruto fechado e negros deiscentes (fruto aberto com painas expostas. No segundo, a germinação das sementes de árvores da mesma idade e com diferentes DAP's: pequeno (5,4 cm, médio (9,1 cm e grande (13,2 cm. No terceiro, a germinação das sementes com diferentes quebra de dormência: testemunha; água por 24 e 48 horas; água a 80ºC até esfriar; H2SO4 por ½ e 1 minuto com e sem paina; queima da paina em peneira metálica; e semeio de sementes com a paina. As sementes germinaram em gerbox sobre papel de filtro, em câmara de germinação, nas temperaturas de 20ºC, 30ºC e 25ºC, no primeiro, segundo e terceiro experimentos, respectivamente. As sementes de pau-de-balsa germinaram melhor e mais rápido quando coletadas de frutos negros a negros deiscentes, ou quando coletadas de árvores com menor e médio diâmetros, ou quando tratadas com água quente a 80ºC até esfriar, ou com ácido sulfúrico por ½ ou 1 minuto com ou sem paina. Os tratamentos com ácido tem a vantagem de quebrar a dormência da semente e dissolver a paina. As sementes recém colhidas e germinadas não apresentaram dormência tegumentar.The objective of this study was to evaluate the germination of "pau-de-balsa" (Ochroma lagopus Sw., Bombacaceae seed as a function of maturation stages of fruits, the germination of seeds harvested from trees with different diameters at height breast (DBH, and the germination of seed with different treatments to break dormancy. In the first experiment, the germination of seeds

  17. The Role of Residential Communities for the Academic and Social Success of Undergraduate Women in STEM Majors: The Case of a Public University in Ethiopia

    Science.gov (United States)

    Wuhib, Frehiwot Wondimu

    This study is an exploratory case study which explored the residential environment of an Ethiopian public university on its role for the social and academic integration of undergraduate women in Science, Technology, Engineering, and Mathematics (STEM) fields. It also explained how the social and academic integration of the women contributed for their overall college success. There were three groups of participants; undergraduate women in STEM, female resident proctors, and relevant officials from the university and the Ministry of Education of the Ethiopian government. Each of the participants were interviewed on a one-on-one basis and the interviews were transcribed and coded for the analysis. Supportive quantitative data about the enrollment, performance and retention of students were also gathered from the university's registrar office and analyzed quantitatively to support the qualitative data obtained through interviews. The study was framed by Tinto's Integration Model and data were interpreted using Third World feminist theory. The findings showed that due to the fact that all same-sex, same-major women living in the same rooms, and all who live in one dorm take similar courses throughout their program, and dormitories serving multiple roles, including being collaboration spaces, played a big role for better social and academic integration of the women. It is also found that their social and academic integration helped them to better perform in their majors by enhancing their sense of belonging in the male-dominated STEM majors, enhancing their commitment, and promoting peer encouragement. On the other hand, the findings also showed that there were some factors which have negative influence in the integration process such as negative stereotypes against the presence and good performance of women in STEM, lack of support system, and limited interaction with faculty. So, the study recommends that working on improving the negatively influencing factors will

  18. Quebra de dormência, viabilidade e conservação de sementes de buriti (Mauritia flexuosa Dormancy breaking, viability and conservation of Mauritia flexuosa seeds

    Directory of Open Access Journals (Sweden)

    Maria Roseli Nicoli Spera

    2001-12-01

    Full Text Available Os objetivos deste trabalho foram avaliar a viabilidade de embriões de buriti (Mauritia flexuosa L. pelo teste de tetrazólio e cultivo in vitro, o tratamento térmico na quebra de dormência das sementes, e o efeito do armazenamento em duas temperaturas na conservação das sementes. A viabilidade de embriões de sementes recém-colhidas foi condizente com os resultados de germinação de embriões in vitro, com valores superiores a 90%. O estudo da quebra de dormência foi feito com tratamento das sementes em temperaturas de 30, 35 e 40ºC por períodos de 15, 30 e 45 dias. Até 15 e 30 dias, os resultados obtidos foram maiores que os do controle. Sementes armazenadas em saco de plástico por um período de quatro meses e meio, sob temperatura de 20ºC, apresentaram resultados de germinação de embrião superiores a 90%, e sob temperatura de 30ºC houve perda total da viabilidade.The present work was conducted to evaluate the viability of embryos of Mauritia flexuosa L. by tetrazolium test and in vitro culture, high temperature treatment on dormancy breaking, and the effect of storage at different temperatures on seed conservation. The viability of newly harvested embryos presented a high correlation with the rate of embryo germination in vitro. The rate of viability was higher than 90% either when evaluated by the tetrazolium method or by in vitro embryo culture. Dormancy breaking of seeds was tested by treating the seeds under temperatures of 30, 35 and 40ºC for 15, 30, and 45 days. Great variation was observed among treatments, but, at least on day 15 and on day 30, the germination was higher than in the control. Seeds stored in plastic bags for four and a half months and temperature of 20ºC presented a germination rate higher than 90% while in the seeds stored at 30ºC the viability was zero.

  19. Waste not: WaDImena | IDRC - International Development Research ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2011-02-28

    Feb 28, 2011 ... In Ouled-Bessem, Algeria, treated wastewater from a local treatment plant is being used for supplemental irrigation of cereal crops, ... sinks, and showers) from dorms at Mu'tah University is being reused for local agriculture.

  20. Staffing and Technology Maximize Dorm Security.

    Science.gov (United States)

    George, Stephen C.

    1996-01-01

    Loyola University of Chicago uses uniformed guards and electronic monitoring to prevent unauthorized entry into its 11 residence halls. Access to all residence halls is regulated by bar-code readers. Student ID cards also have color-coded stickers corresponding to specific residence halls. (MLF)

  1. Interior design criteria for successful hospital patient rooms

    OpenAIRE

    Bilir, Seda

    1997-01-01

    Ankara : The Department of Interior Architecture and Environmental Design and Institute of Fine Arts of Bilkent University, 1997. Thesis (Master's) -- Bilkent University, 1997. Includes bibliographical references leaves 94-99 In this study, the design requirements of hospital acute-care patient rooms, which support the recovery and well-being of the patients, are examined. Patients' psycho-spatial needs which may be complementary to the healing effects of the medical treatme...

  2. Variações do conteúdo de glucose, frutose e sorbitol em gemas e ramos de macieira durante a dormência Variations of glucose, frutose and sorbitol content in buds and stems of apple tree during the dormancy period

    Directory of Open Access Journals (Sweden)

    Ruy Inacio Neiva de Carvalho

    2006-12-01

    Full Text Available O objetivo deste trabalho foi determinar as variações do conteúdo de glucose, frutose e sorbitol em gemas e ramos de um ano de macieira durante o período de dormência. Os ramos da cultivar "Imperial Gala" foram coletados em Porto Amazonas-PR, em intervalos de 21 dias, de abril a agosto (19/04, 10/05, 31/05, 21/06, 12/07, 02/08 e 23/08, e receberam ou não tratamento com frio suplementar de 1.440 horas à temperatura de 4 a 7°C. As análises dos carboidratos foram realizadas em gemas e porções de ramos adjacentes às primeiras por cromatografia líquida de alta eficiência (HPLC. Ocorreu um acúmulo de glucose, frutose e sorbitol nas gemas de macieira durante a dormência. O acúmulo de glucose e frutose nos ramos aconteceu até o início de agosto quando, em seguida, houve redução, enquanto o sorbitol decresceu até junho e, em seguida, elevou-se até o final de agosto. O tratamento com frio ao longo da dormência modificou as variações dos conteúdos de carboidratos nas gemas e ramos de macieira.This research was aimed at evaluating the variations of glucose, frutose and sorbitol content in one year old buds and stems of apple trees during the dormancy period. The stems of cv. Imperial Gala were collected in Porto Amazonas, Parana State, Brazil, at intervals of 21 days from April to August (April 19th, May 10th, May 31st, June 21st, July 12th, August 2nd and August 23rd and were treated or not with 1,440 hours of chill (4 to 7°C. The carbohydrates were analysed in buds and stem tissues close to buds by high performance liquid chromatography (HPLC. There was an increase of glucose, frutose and sorbitol content in apple tree buds during the dormancy. An increase of glucose and frutose content in stems occured until August 2nd followed by a significative reduction, while the sorbitol content decreased until June 21st followed by an increase until August 31st. The chill treatment during the dormancy period modified the variations of

  3. Breaking of Dormancy of Erythrina crista-galli Seeds Quebra de Dormência de Sementes de Erythrina crista-galli

    Directory of Open Access Journals (Sweden)

    Ariadne Josiane Castoldi Silva

    2011-03-01

    Full Text Available

    Erythrina crista-galli L., Fabaceae, a medium-sized N-fixing tree, is native to flooding soils of several Brazilian biomes. Its cultivation has interest for ornamental and ecological restoration purposes. Information on seed coat dormancy is conflicting and inexact, therefore the present work aimed to verify it and to define methods for its overcoming. The study was composed by two experiments, using seed lots collected in different dates. Seeds were subjected to inducing germination treatments by chemical scarification (ACS commercial sulfuric acid, d=1,84 g/cm³ and thermic scarification (hot water. Results demonstrated high germination under acid scarification (up to 95% and inferior when submitted to thermic scarification (reaching up to 43%; witness treatments showed germination between 2% and 13%. The results confirmed the presence of seed coat dormancy. It is recommendable, to break the dormancy of lots which are similar to the investigated ones (three to 27 months after seed collection, the immersion in sulfuric acid during 30 minutes. Seeds maintained its total germinative capacity after storage for 27 months in paper bag in cold chamber (5 °C and 98 % air humidity. 
    Erythrina crista-galli L., Fabaceae, conhecida por corticeira-do-banhado, é uma árvore de porte médio, fixadora de nitrogênio, ocorrendo em vários biomas brasileiros, em terrenos alagadiços. Seu cultivo tem interesse para fins ornamentais e restauração ambiental. Informações sobre dormência tegumentar de suas sementes são conflitantes e imprecisas; por isso, o presente trabalho teve por objetivo verificá-la e, em caso positivo, definir métodos para a superação. O estudo foi composto por dois experimentos, usando lotes de sementes coletadas em datas diferentes. As sementes passaram por tratamentos de escarificação química (ácido sulfúrico comercial padrão ACS, d=1,84 g/cm³ e térmica (

  4. Fostering the practice of rooming-in in newborn care

    Directory of Open Access Journals (Sweden)

    Saurabh R. Shrivastava

    2013-09-01

    Full Text Available Practice of rooming-in meant that baby and mother stayed together in the same room day and night in the hospital, right from the time of delivery till the time of discharge. Adoption of rooming-in offers multiple benefits to the newborn, mother, and mother-child as a unit. It is a cost-effective approach wherefewer instruments are required and spares additional manpower. Rooming-in endeavors the opportunity to contribute signifi cantly in the child’s growth, development and survival by assisting in timely initiation of breastfeeding. To ensure universal application of rooming-in in hospitals, a comprehensive and technically sound strategy should be formulated and implemented with active participation of healthcare professionals. Measures such as advocating institutional delivery through outreach awareness activities; adoption of baby-friendly hospital initiative; inculcating a sense of ownership among health professionals, can be strategically enforced for better maternal and child health related outcomes.

  5. Dinâmica da dormência de gemas de dois anos de macieira 'Imperial Gala' em região de baixa ocorrência de frio Dormancy dynamics of two year old buds of 'Imperial Gala' apple tree in a region of low chill occurence

    Directory of Open Access Journals (Sweden)

    Ruy Inacio Neiva de Carvalho

    2004-12-01

    Full Text Available O objetivo deste trabalho foi determinar a dinâmica da dormência de gemas em ramos de dois anos de macieira 'Imperial Gala' com ou sem frio suplementar durante o outono e inverno, cultivadas em Porto Amazonas - PR, região de baixa ocorrência de frio. Os ramos foram coletados em intervalos de 21 dias, de abril a agosto (19-04, 10-05, 31-05, 21-06, 12-07, 02-08 e 23-08 e receberam ou não tratamento com frio suplementar de 1.440 horas, à temperatura de 4 a 7° C. A avaliação da dormência foi realizada pelo teste biológico de estacas de nós isolados (temperatura de 25° C e fotoperíodo de 16 horas por meio dos parâmetros: tempo médio para brotação (TMB, velocidade de brotação (VB, taxa final de brotação (TF, taxa de brotações vigorosas (TBV e tempo médio para aparecimento de folhas abertas (TMFA. A dormência mais intensa de gemas de dois anos ocorre no final de maio, com oscilações até o início de agosto. A aplicação de 1.440 horas de frio suplementar de 4 a 7° C altera a dinâmica da dormência das gemas de dois anos, reduzindo o seu tempo médio de brotação. Uma vez propiciada a brotação de gemas não-dormentes de dois anos, as mesmas possuem boa capacidade para se desenvolver.This work aims to evaluate the dormancy dynamics of two year old apple tree buds with or without supplementary chill during autumn and winter, in a region of low chill occurence. The stems were collected in Porto Amazonas, Parana State, Brazil, at intervals of 21 days from April to August (April 19th, May 10th, May 31st, June 21st, July 12th, August 2nd and August 23rd and were either treated or not with 1,440 hours of chill (4 to 7° C. The evaluation of dormancy was observed through the biological test of single node cuttings under controlled conditions (25° C and long days of 16 hours by the following parameters: average time for budburst (TMB, velocity of budburst (VB, final rate of budburst (TF, rate of vigorous budburst (TBV and

  6. Room Allocation Optimisation at the Technical University of Denmark

    DEFF Research Database (Denmark)

    Bagger, Niels-Christian Fink; Larsen, Jesper; Stidsen, Thomas Riis

    2014-01-01

    As at many other universities the Technical University of Denmark (DTU) faces the challenge of solving a case of the curriculum based university course timetabling problem (CUCTT) multiple times a year. However, there are some slight modications to the CUCTT problem usually described in the liter...... at overlapping time slots, since the students are to ensure by themselves that their courses do not overlap. The problem was rst considered in the masters' thesis [1] and the project here is an extension of the work done in that thesis....

  7. A Strategic View of University Timetabling

    DEFF Research Database (Denmark)

    Lindahl, Michael; Mason, Andrew; Stidsen, Thomas Jacob Riis

    2018-01-01

    University Timetabling has traditionally been studied as an operational problem where the goal is to assign lectures to rooms and timeslots and create timetables of high quality for students and teachers. Two other important decision problems arise before this can be solved: what rooms are necess......University Timetabling has traditionally been studied as an operational problem where the goal is to assign lectures to rooms and timeslots and create timetables of high quality for students and teachers. Two other important decision problems arise before this can be solved: what rooms....... The relationship and differences between operational, tactical and strategic timetabling problems are reviewed. Based on the formulation of curriculum-based course timetabling and data from the Second International Timetabling Competition (ITC 2007), three new bi-objective mixed-integer models are formulated. We...

  8. Dormancy break in seeds of "quina" (Strychnos pseudoquina A. St.-Hil. Superação da dormência de sementes de quina (Strychnos pseudoquina A. St.-Hil.

    Directory of Open Access Journals (Sweden)

    J.M. Vasconcelos

    2011-01-01

    Full Text Available "Quina" (Strychnos pseudoquina A. St. Hil is a medicinal plant species from the Brazilian Cerrado. As its seeds show dormancy, they were subjected to the treatments pre-cooling at 5ºC during 7 days, pre-heating at 40ºC during 7 days, pre-soaking in sulfuric acid PA during 5 and 15 min, pre-soaking in boiling water during 5 and 15 min, pre-soaking in 100 and 200 ppm gibberellic acid during 48 h, pre-soaking in distilled water during 24 and 48 h, and mechanical scarification to break dormancy. Counts were daily conducted from the 2nd day after the experiment implementation until the germination stabilization at the 65th day. The germination speed index (GSI and the germination percentage were evaluated. Germination rates above 96% were reached in seeds pre-soaked in water during 48 h and substrate moistened with water or KNO3.A quina (Strychnos pseudoquina A. St.-Hil é espécie medicinal do Cerrado Brasileiro. As sementes apresentam dormência e, por isso, foram submetidas aos tratamentos pré-resfriamento a 5ºC durante 7 dias, pré-aquecimento a 40ºC durante 7 dias, pré-embebição em ácido sulfúrico P.A. durante 5 e 15 minutos, pré-embebição em água fervente durante 5 e 15 minutos, pré-embebição em ácido giberélico a 100 e 200 ppm, durante 48 horas, pré-embebição em água destilada durante 24 e 48 horas e escarificação mecânica, visando à superação da dormência. Foram realizadas contagens diárias entre o 2º dia após a implantação do experimento até a estabilização da germinação, que ocorreu no 65º dia. Foram avaliados o índice de velocidade de germinação (IVG e a porcentagem de germinação. Taxas de germinação acima de 96% foram atingidas em sementes pré-embebidas em água durante 48 horas e substrato umedecido com água ou KNO3.

  9. Self-Organizing Units in an Interdisciplinary Course for Pervasive Computing Design

    OpenAIRE

    McNair, Lisa; Newswander, Chad; Coupey, Eloise; Dorsa, Ed; Martin, Tom; Paretti, Marie

    2009-01-01

    We conducted a case study of a design course that focused on bringing together students from engineering, industrial design, and marketing to use pervasive computing technologies to design, coordinate, and build a “smart” dorm room for disabled individuals. The class was loosely structured to encourage innovation, critical thinking and interdisciplinarity. In this environment, teams were created, disassembled, and re-created in a self-organizing fashion. With few norms, teams were expected to...

  10. [Performance development of a university operating room after implementation of a central operating room management].

    Science.gov (United States)

    Waeschle, R M; Sliwa, B; Jipp, M; Pütz, H; Hinz, J; Bauer, M

    2016-08-01

    The difficult financial situation in German hospitals requires measures for improvement in process quality. Associated increases in revenues in the high income field "operating room (OR) area" are increasingly the responsibility of OR management but it has not been shown that the introduction of an efficiency-oriented management leads to an increase in process quality and revenues in the operating theatre. Therefore the performance in the operating theatre of the University Medical Center Göttingen was analyzed for working days in the core operating time from 7.45 a.m. to 3.30 p.m. from 2009 to 2014. The achievement of process target times for the morning surgery start time and the turnover times of anesthesia and OR-nurses were calculated as indicators of process quality. The number of operations and cumulative incision-suture time were also analyzed as aggregated performance indicators. In order to assess the development of revenues in the operating theatre, the revenues from diagnosis-related groups (DRG) in all inpatient and occupational accident cases, adjusted for the regional basic case value from 2009, were calculated for each year. The development of revenues was also analyzed after deduction of revenues resulting from altered economic case weighting. It could be shown that the achievement of process target values for the morning surgery start time could be improved by 40 %, the turnover times for anesthesia reduced by 50 % and for the OR-nurses by 36 %. Together with the introduction of central planning for reallocation, an increase in operation numbers of 21 % and cumulative incision-suture times of 12% could be realized. Due to these additional operations the DRG revenues in 2014 could be increased to 132 % compared to 2009 or 127 % if the revenues caused by economic case weighting were excluded. The personnel complement in anesthesia (-1.7 %) and OR-nurses (+2.6 %) as well as anesthetists (+6.7 %) increased less compared to the

  11. Noise and room acoustic conditions in a tertiary referral hospital in Seoul, Korea

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Cho, Wan-Ho; Chang, Ji-ho

    2018-01-01

    Noise levels and room acoustic parameters at a tertiary referral hospital, Seoul National University Hospital in Korea, are investigated. Through a questionnaire, acoustically problematic rooms are identified. Noise levels in emergency rooms (ERs) and intensive care units (ICUs) are measured over...... level for the first night was 66 dBA, which came down to 56 dBA for the next day. The reason for the higher noise level for the first night in the ICU was frequent alarm sound and treatment noise related to a critical patient. The noise level in the measured ERs is about 10 dB lower than those measured...... about three days. Acoustically critical and problematic rooms in the otolaryngology department are measured: examination rooms, operating rooms, nurse stations, patient rooms, and audiometric rooms. The equivalent A-weighted noise level, LAeq, ranges from 54 to 56 dBA in two ERs. In an ICU, the noise...

  12. Photographic art in exam rooms may reduce white coat hypertension.

    Science.gov (United States)

    Harper, Michael B; Kanayama-Trivedi, Stacy; Caldito, Gloria; Montgomery, David; Mayeaux, E J; DelRosso, Lourdes M

    2015-12-01

    Blood pressure (BP) elevation in medical office settings in patients who are normotensive in nonmedical settings is an effect known as 'white coat hypertension'. This phenomenon is thought to be due to situational anxiety caused by the experience of visiting a doctor and the anxiety-inducing nature of the medical office. Our study was designed to determine if carefully selected photographic art could counter the anxiety that causes white coat hypertension and lead to lower BP recordings in some patients. 117 adults, non-pregnant patients from the Louisiana State University Health Sciences Center Family Medicine Resident Clinic participated in this study. After the triage nurse measured the BP, the patients were randomly placed in either an exam room with standard medical posters (control room) or in an exam room with photographic art (photo room). The BP was measured in the exam room. After the medical visit, the patients switched rooms and the BP was measured a third time. The patients were asked to fill out a questionnaire to identify room preference. On average, the BP obtained in the control rooms was higher than that obtained in the photo rooms. There was a statistically significant difference between the mean arterial pressure, systolic BP and diastolic BP between the control room and the photo room. Landscape photographic art may have the beneficial effect of reducing BP in medical office examination rooms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Beyond the Cultural Borders of the Dining Room: a Reader-Oriented Approach to A. R. Gurney's The Dining Room

    Directory of Open Access Journals (Sweden)

    Esraa Jalal Jawad Al-Gawhari

    2018-02-01

    Full Text Available A. R. Gurney's The Dining Room is a work basically written to address issues related to the White Anglo-Saxon Protestant (henceforth WASP culture. The work is rich with elements (the structure, the setting, the characters, and the themes, inviting to the WASP audience to interact with it, recognizing their cultural identity. The present study aims at proving that those elements can also endow the text with wider horizons when perceived by other audiences through supporting the symbol of the dining room. The study examines them in an attempt to see their effects on the WASP audience. Then, it views them as factors adding to the text a universal touch.

  14. Control room philosophy: Principles of control room design and control room work

    International Nuclear Information System (INIS)

    Skriver, Jan; Ramberg, Jasmine; Allwin, Pernilla

    2006-01-01

    In order to provide insights for improvement of work in control rooms several factors have to be considered. Knowledge of principles including control room philosophies will guide the recommended improvements. In addition to knowledge about specific principles an advantage for an organization can be an understanding of similarities and policies used in other high risk industry. The report has been developed on the basis of a document analysis of international standards and other guiding documents. (NUREG 0711, ISO 11064, ISO 6385, IEC 60964). In addition to the document analysis which has strived to compare the documents to see similarities in important principals, experience from working with control room design, modifications and evaluations in other high risk industries has pervaded the report. Important principles have been identified which are recommended to be included in a control room philosophy. Many of these are similar to the principles identified in the international standards. An additional principal which is regarded as important is the utilization of Key Performance Indicators (KPI) which can be used as a measure to target preventative means. Further more it is critical that the control room philosophy is easy to access and comprehend for all users. One of the challenges that remain after having developed a control room philosophy is how to utilize it in the daily work situation. It is vital that the document remains as a living document, guiding the continual improvement of the control room in the various life cycle stages

  15. Performance of the Operating Room Personnel in following of the standards of Infection Control in the Educational Hospitals of Yasuj University of Medical Sciences in 2009

    Directory of Open Access Journals (Sweden)

    A Rostaminejad

    2011-04-01

    Full Text Available Introduction & Objective: Surgical wound infection is one of the common nosocomial infections. During operation, members of the surgical team which are in contact with the tissue incision should observe the standards of infection control in the operating room since it has a great role in prevention and control of these infections. The present study aimed to determine the performance of the operating room personnel in observing the standards of infection control in educational hospitals of Yasuj University of Medical Sciences in 2009. Materials & Methods: Forty two operating room personnel participated in this cross-sectional analytic-descriptive study. A check list was used for unnoticeably collecting the data about the performance of personnel in respect of infection control standards at three different times. Their performances were classified into four levels (very weak, weak, moderate and good and the results were shown as absolute and relative frequency distribution. Data were analyzed using Chi-square and Fischer exact test by the SPSS software. Results: Performance of personnel in following the standards of infection control in this study was moderate. Conclusion: The results indicate that the participants of the study do not follow some of the standards of infection control in the operating rooms. Therefore, further activities of the committees of infection control and using of new antiseptic for surgical scrub are recommended.

  16. Dinâmica da dormência de gemas de videira e quivizeiro em região de baixa ocorrência de frio Dormancy dynamics of grape and kiwi tree buds in a region of low chill occurrence

    Directory of Open Access Journals (Sweden)

    Luiz Antonio Biasi

    2010-12-01

    Full Text Available O objetivo desta pesquisa foi determinar a dinâmica da dormência de gemas de videira cv. Niagara Branca e de quivizeiro cv. Bruno, em região de baixa ocorrência de frio. Os experimentos foram realizados nos anos de 2007 e 2008, com coletas de ramos a cada duas semanas, em pomares localizados em Pinhais-PR. Na última coleta, um grupo adicional de ramos foi coletado e mantido em refrigerador a temperatura de 4 a 7º C, por 1.440 horas. A avaliação da dormência foi realizada por meio do teste biológico de estacas de nós isolados em sala de crescimento, à temperatura de 25º C e fotoperíodo de 16 horas. Foi realizada a quantificação de horas de frio (HF e de unidades de frio (UF ocorridas na região. As duas espécies foram avaliadas como experimentos distintos. O delineamento experimental adotado foi o completamente casualizado, com doze tratamentos em 2007 e onze tratamentos em 2008, ambos com quatro repetições e dez estacas por unidade experimental. A endodormência de gemas de quivizeiro 'Bruno' instala-se a partir de abril e atinge maior intensidade do final de maio à segunda metade de junho. A saída da endodormência pode ocorrer naturalmente até o fim de agosto, mas com variações entre os anos. A endodormência de gemas de videira 'Niagara Branca' instala-se em abril e mantém-se intensa até maio. A saída natural da endodormência ocorre da metade de agosto ao início de setembro.The objective of this work was to evaluate the dormancy dynamic of 'Niagara Branca' grape and 'Bruno' kiwi tree buds in a region of low chill occurrence. The experiments were carried out in 2007 and 2008 through cut branches every two weeks in orchards in Pinhais-PR. In the last date, an additional group of stems was collected and maintained in a refrigerator at temperature of 4 to 7º C by 1440 hours. The evaluation of dormancy was observed by the biological test of single node cuttings into a growth room with temperature of 25º C and

  17. Superação de dormência em sementes de Gleditschia amorphoides Taub. Overcoming of seed dormancy in Gleditschia amorphoides Taub.

    Directory of Open Access Journals (Sweden)

    Michele Fernanda Bortolini

    2011-05-01

    Full Text Available O trabalho teve como objetivo avaliar métodos para a superação da dormência de sementes de sucará. As sementes receberam os seguintes tratamentos: 1 testemunha; 2 escarificação mecânica; 3 escarificação mecânica + água/24h; 4 escarificação mecânica + água quente/24h; 5 água quente/24h; 6 ácido sulfúrico (H2SO4/1h; 7 H2SO4/2h; 8 H2SO4/1h + água/24h; 9 H2SO4/30min + água corrente/4h; 10 escarificação mecânica + água corrente/4h. O teste de germinação foi conduzido em rolos de papel Germitest acondicionados em câmara de germinação, à 25°C, com fotoperíodo de 12h por 26 dias. Avaliou-se também o tempo e a velocidade média de germinação. O delineamento experimental foi inteiramente casualizado, com quatro repetições de 25 sementes. O melhor desempenho germinativo foi registrado para as sementes submetidas à escarificação mecânica e química, com médias entre 76 e 98% de germinação, respectivamente, 2,17 a 2,88 dias para tempo médio de germinação e 0,46 a 0,47 sementes/dia para velocidade média de germinação, demonstrando serem estes os melhores métodos para superação da dormência de sementes dessa espécie.The objective of this research was to evaluate methods to overcome dormancy of seeds of Gleditschia amorphoides. For dormancy's overcoming the seeds received the following treatments: 1 control; 2 mechanical scarfication 3 mechanical scarfication + water/24h; 4 mechanical scarfication + hot water/24h; 5 hot water/24h; 6 sulfuric acid (H2SO4/1h; 7 H2SO4/2h; 8 H2SO4/1h + water/24h; 9 H2SO4/30min + flowing water/4h; 10 mechanical scarfication + flowing water/4h. Germination was done in rolls of Germitest conditioned in a germination chamber under 25°C, during 12h for 26 days. Percentage, time and average speed of germination were evaluated. The experimental design was completely casual with 10 treatments, 4 repetitions and 25 seeds. The best results were recorded for treatments with mechanical

  18. Indoor Air Quality in Brazilian Universities

    Directory of Open Access Journals (Sweden)

    Sonia R. Jurado

    2014-07-01

    Full Text Available This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC (n = 15 and naturally ventilated (NV (n = 15 classrooms. The parameters of interest were indoor carbon dioxide (CO2, temperature, relative humidity (RH, wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively. The average indoor airborne dust concentration exceeded the Brazilian standards (<80 µg/m3 in both NV and AC classrooms. The levels of CO2 in the AC rooms were significantly different from the NV rooms (1433.62 ± 252.80 and 520.12 ± 37.25 ppm, respectively. The indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem.

  19. Room source management decontamination in Uruguay

    International Nuclear Information System (INIS)

    Blanco, D.; Montanez, Osvaldo

    1998-01-01

    A surface,work materials and tools contamination it produced for Ra-226 sources management in des use in Uruguayan radioactive waste and sources management and storage room specifically in the Uruguay Republic University in Nuclear Search Center. A surface contamination direct was performed measurement with Eberline alpha particles Contamat FHT 111M with 42 496/30 sounder. It found greater and least contamination grade in all cement floor as well as in tables where was managed with Ra-226 sources. A value measured surface contamination can see in the Room scheme with more 200 Bq/cm in extension small places. A segregation between work materials and tools considerate d free contamination was realized. The contaminated objects was separated for a future treatment. A proceeding followed in the decontamination was inhale, abrasion,sweep essays in different representative zones, obtain decontamination factors and residual activity

  20. Superação de dormência em sementes de manjericão (Ocimum basilicum L. Overcoming dormancy in seeds of basil (Ocimum basilicum L.

    Directory of Open Access Journals (Sweden)

    H.T.R. Amaro

    2012-01-01

    Full Text Available O objetivo do trabalho foi avaliar a eficiência de tratamentos pré-germinativos na superação da dormência de sementes de manjericão, produzidas no Horto de Plantas Medicinais da Unimontes, em fevereiro de 2011. Foram realizadas as seguintes determinações para avaliação da qualidade fisiológica das sementes: teor de água, germinação, primeira contagem de germinação, emergência de plântulas e índice de velocidade de emergência. O delineamento experimental utilizado foi inteiramente casualizado com quatro repetições de 50 sementes por tratamento, sendo T1- testemunha; T2 - pré esfriamento das sementes em câmara tipo BOD sob temperatura de 10ºC por 4 dias; T3 - embebição das sementes em água destilada por 24 horas; T4 - embebição das sementes em solução contendo KNO3 a 0,2 % por 5 minutos e T5 - sementes submetidas em água destilada a temperatura de 70ºC por 5 minutos. Os dados foram submetidos à análise de variância e as médias comparadas pelo teste Scott - Knott a 5% de probabilidade. O tratamento pré esfriamento em câmara tipo BOD a 10ºC por 4 dias reduz a dormência e promove incrementos na qualidade fisiológica das sementes do manjericão.Aiming in order to assess the effectiveness of treatments to overcome dormancy in seeds of basil, an experiment was conducted at the Laboratory of Seed Analysis of Unimontes. Following determinations were performed to evaluate the physiological quality of seeds, water content, germination, first count germination, seedling emergence and emergence speed index. The experimental design was completely randomized design with four replications of 50 seeds per treatment, which consisted of: T1 - control, T2 - pre-cooling of the seed chamber BOD at a temperature of 10ºC for 4 days, T3 - soaking the seeds in water distilled for 24 hours, T4 - soaking the seeds in a solution containing 0,2% for 5 minutes and T5 - submitted seeds in distilled water at 70ºC for 5 minutes. Data

  1. Milk Vending Does Not Improve College Students' Milk and Calcium Intakes.

    Science.gov (United States)

    Rose, Angela M; Williams, Rachel A; Hanks, Andrew S; Kennel, Julie A; Gunther, Carolyn

    2018-03-01

    In the transition from adolescence to young adulthood, overall diet quality decreases, including a reduction in both dairy and calcium consumption. The objective of this pilot study was to determine the impact of milk vending on milk and calcium intakes in college students. Participants were 124 college students living in dorms at a large public university (Fall 2012). Milk vending machines were installed in two campus dorms. Before and 2 months after installation, students were surveyed about milk and calcium intakes, as well as attitudes regarding milk vending. Sales data for the newly installed machines were also collected between the pre- and posttest surveys. Students reported similar milk and calcium consumption before and after the intervention. Mean calcium intakes were lower than the recommended dietary allowance for students in either life stage group (18 years old or 19 years and older). Milk vending sales data showed that during the study period, approximately nine bottles of milk were bought each day from the two dorms combined. Results from this study suggest that milk vending alone may not be an effective strategy for preventing the commonly observed decrease in milk and calcium intakes among college students.

  2. An Investigation of the Prevalence of Antibiotic Resistance in Enterococcus Species Isolated from Delivery Room of University Hospital of Qom City, 2015, Iran

    Directory of Open Access Journals (Sweden)

    Faezeh Kabiri

    2016-06-01

    Full Text Available Background and Objectives: Enterococci are Gram-positive cocci that are found in abundance in the environment. The ability of these bacteria for long-term survival in hospital environment, increases the chance of patients for infections caused by this bacterium. Therefore, identification of possible sources and reservoirs is helpful in identifying the potential sources in sudden outbreaks. The current study was conducted to determine the prevalence rate and antibiotic resistance pattern in environmental Enterococcus isolates collected from delivery room environment of Alzahra and Izadi university hospitals in Qom. Methods: In this descriptive cross-sectional study, over a period of 3 month, sampling was performed using swabbing method from delivery rooms of alzahra and izadi hospitals in Qom, and were examined for the presence of Enterococci. After isolation, Enterococcus species were examined using different biochemical tests, and the antibiotic resistance pattern in the environmental was assessed according to disk-diffusion test according to Clinical and Laboratory Standards Institute (CLSI standards. The data were described by frequency tables. Results: In this study, out of 216 obtained isolates, 7(3.2% belonged to Enterococcus genus. 4(57% out of 7 Enterococcus strains isolated from surfaces of delivery room, had multiple resistances based on antibiotic sensitivity test using antiobiogram test. Conclusion: According to increasing growth of nosocomial infection caused by resistant strains of Enterococcus spp. and their spread in hospital environment, use of infection control measures are necessary to eliminate the potential sources and prevent the infection.  

  3. Room Acoustics

    Science.gov (United States)

    Kuttruff, Heinrich; Mommertz, Eckard

    The traditional task of room acoustics is to create or formulate conditions which ensure the best possible propagation of sound in a room from a sound source to a listener. Thus, objects of room acoustics are in particular assembly halls of all kinds, such as auditoria and lecture halls, conference rooms, theaters, concert halls or churches. Already at this point, it has to be pointed out that these conditions essentially depend on the question if speech or music should be transmitted; in the first case, the criterion for transmission quality is good speech intelligibility, in the other case, however, the success of room-acoustical efforts depends on other factors that cannot be quantified that easily, not least it also depends on the hearing habits of the listeners. In any case, absolutely "good acoustics" of a room do not exist.

  4. Science Hall of Atomic Energy in Research Reactor Institute, Kyoto University

    International Nuclear Information System (INIS)

    Hayashi, Takeo

    1979-01-01

    The Science Hall of Atomic Energy was built as a subsidiary facility of the Research Reactor Institute, Kyoto University. The purpose of this facility is to accept outside demands concerning the application of the research reactor. The building is a two story building, and has the floor area of 901.47 m 2 . There are an exhibition room, a library, and a big lecture room. In the exhibition room, models of the Kyoto University Research Reactor and the Kyoto University Critical Assembly are placed. Various pictures concerning the application of the reactor are on the wall. In the library, people from outside of the Institute can use various books on science. Books for boys and girls are also stocked and used for public use. At the lecture room, various kinds of meeting can be held. (Kato, T.)

  5. Room temperature nanoindentation creep of hot-pressed B6O

    CSIR Research Space (South Africa)

    Machaka, R

    2014-06-01

    Full Text Available of the nanoindentation creep behavior in B6O ceramics. 1 Room temperature nanoindentation creep of hot-pressed B6O Ronald Machakaa,b,* , Trevor E. Derryb,d, Iakovos Sigalasb,c aLight Metals, Materials Science and Manufacturing, Council for Scientific..., University of the Witwatersrand, Private Bag 3, Wits, Johannesburg 2050, South Africa dSchool of Physics, University of the Witwatersrand, Private Bag 3, Wits, Johannesburg 2050, 2050 South Africa Abstract: Nanoindentation has become a widely...

  6. Room temperature Compton profiles of conduction electrons in α-Ga ...

    Indian Academy of Sciences (India)

    B P PANDA and N C MOHAPATRA*. Department of Physics, Chikiti Mahavidyalaya, Chikiti 761 010, India. £Department of Physics, Berhampur University, Berhampur 760 007, India. Email: ncmphy123@hotmail.com. MS received 18 January 2003; accepted 21 June 2003. Abstract. Room temperature Compton profiles of ...

  7. Three-dimensional point-cloud room model in room acoustics simulations

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    acquisition and its representation with a 3D point-cloud model, as well as utilization of such a model for the room acoustics simulations. A room is scanned with a commercially available input device (Kinect for Xbox360) in two different ways; the first one involves the device placed in the middle of the room...... and rotated around the vertical axis while for the second one the device is moved within the room. Benefits of both approaches were analyzed. The device's depth sensor provides a set of points in a three-dimensional coordinate system which represents scanned surfaces of the room interior. These data are used...... to build a 3D point-cloud model of the room. Several models are created to meet requirements of different room acoustics simulation algorithms: plane fitting and uniform voxel grid for geometric methods and triangulation mesh for the numerical methods. Advantages of the proposed method over the traditional...

  8. Three-dimensional point-cloud room model for room acoustics simulations

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    acquisition and its representation with a 3D point-cloud model, as well as utilization of such a model for the room acoustics simulations. A room is scanned with a commercially available input device (Kinect for Xbox360) in two different ways; the first one involves the device placed in the middle of the room...... and rotated around the vertical axis while for the second one the device is moved within the room. Benefits of both approaches were analyzed. The device's depth sensor provides a set of points in a three-dimensional coordinate system which represents scanned surfaces of the room interior. These data are used...... to build a 3D point-cloud model of the room. Several models are created to meet requirements of different room acoustics simulation algorithms: plane fitting and uniform voxel grid for geometric methods and triangulation mesh for the numerical methods. Advantages of the proposed method over the traditional...

  9. Online Learning Room for ”Flipped Classroom”

    DEFF Research Database (Denmark)

    Bugge, Ellen Margrethe; Nielsen, Linda Susanna Hauschildt

    2014-01-01

    working actively and innovatively to create a didactic design in our online learning rooms in our LMS that satisfy the demands for flipped learning and at the same time adapted to the special needs of each learning module at the nursing education programme. Keywords: Online learning, flipped classroom......Abstract The “flipped classroom” learning concept is an alternative way of teaching & learning. The fundamental idea of the "flipped classroom" is to change the way students prepare for classes and the work that takes place when the students are together in the classroom. This integrates online...... learning with learning in the classroom. The learning room must support the students’ unassisted learning, their preparation for class and their preparation for supervision in both a motivating and clear way. At the Nursing Education Programme at University College Lillebaelt in Denmark, we have been...

  10. Indoor air quality in Brazilian universities.

    Science.gov (United States)

    Jurado, Sonia R; Bankoff, Antônia D P; Sanchez, Andrea

    2014-07-11

    This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC) (n = 15) and naturally ventilated (NV) (n = 15) classrooms. The parameters of interest were indoor carbon dioxide (CO2), temperature, relative humidity (RH), wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively). The average indoor airborne dust concentration exceeded the Brazilian standards (indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem.

  11. Research on OpenStack of open source cloud computing in colleges and universities’ computer room

    Science.gov (United States)

    Wang, Lei; Zhang, Dandan

    2017-06-01

    In recent years, the cloud computing technology has a rapid development, especially open source cloud computing. Open source cloud computing has attracted a large number of user groups by the advantages of open source and low cost, have now become a large-scale promotion and application. In this paper, firstly we briefly introduced the main functions and architecture of the open source cloud computing OpenStack tools, and then discussed deeply the core problems of computer labs in colleges and universities. Combining with this research, it is not that the specific application and deployment of university computer rooms with OpenStack tool. The experimental results show that the application of OpenStack tool can efficiently and conveniently deploy cloud of university computer room, and its performance is stable and the functional value is good.

  12. Neutrons field in the neutronic measurements room of the Polytechnic University of Madrid; Campo de neutrones en la sala de medidas neutronicas de la Universidad Politecnica de Madrid

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Gallego, E.; Lorente, A.; Rubio O, I. P., E-mail: hrvegacarrillo@yahoo.com.m [Universidad Politecnica de Madrid, Departamento de Ingenieria Nuclear, C/Jose Gutierrez Abascal No. 2, 28006 Madrid (Spain)

    2010-09-15

    Through of measurements and calculations of a Monte Carlo series has been characterized the neutronic field of the neutronic measurements room of Nuclear Engineering Department of the Polytechnic University of Madrid. The measurements were realized with the Bonner Spheres Spectrometer that allowed establish the spectra on the new stainless steel panel and at different distances measured regarding the source. The values of the speed of environmental equivalent dose were measured with an area monitor Bert hold Lb 6411. Through of Monte Carlo methods was built a detailed model of the room with the panel and the spectra were calculated and, with these the values of the environmental equivalent dose were obtained using the conversion coefficients of the ICRP 74 and the Bert hold Lb 6411 response. The calculated values were compared with those measured and was consistency among the results. (Author)

  13. Room with a View: Ethical Encounters in Room 13

    Science.gov (United States)

    Grube, Vicky

    2012-01-01

    In this article, the author describes ethical encounters in Room 13, a schoolroom where children made what they wanted, posed their own questions, and ran an art room like a small business. In Room 13 children had the responsibility to maintain all aspects of the art studio. Specific decisions fell to an annually elected management team, a small…

  14. Operating room management and operating room productivity: the case of Germany.

    Science.gov (United States)

    Berry, Maresi; Berry-Stölzle, Thomas; Schleppers, Alexander

    2008-09-01

    We examine operating room productivity on the example of hospitals in Germany with independent anesthesiology departments. Linked to anesthesiology group literature, we use the ln(Total Surgical Time/Total Anesthesiologists Salary) as a proxy for operating room productivity. We test the association between operating room productivity and different structural, organizational and management characteristics based on survey data from 87 hospitals. Our empirical analysis links improved operating room productivity to greater operating room capacity, appropriate scheduling behavior and management methods to realign interests. From this analysis, the enforcing jurisdiction and avoiding advance over-scheduling appear to be the implementable tools for improving operating room productivity.

  15. Overcoming seed dormancy and early growth of seedlings of Spondias tuberosa, Arr. CâmaraSuperação de dormência de sementes e crescimento inicial de plântulas de umbuzeiro

    Directory of Open Access Journals (Sweden)

    Janete Motta da Silva Gonzaga

    2012-08-01

    Full Text Available Pre-germination treatments such as scarification and the use of growth regulators can provide the dormancy breaking in seeds and enhance the emergence and development of seedlings. The aim of this study was to determine appropriate treatments to overcome seed dormancy and enhance the initial growth of seedlings of Spondias tuberosa. We used a randomized design in factorial 2 x 4, with the following factors: seeds scarified or not scarified and then soaked in water or aqueous solutions of gibberellin, cytokinin and ethylene, with 4 replicates and 15 seeds. There was no significant interaction between scarification treatments and use of growth regulators. Mechanical scarification and soaking seeds in solutions containing umbuzeiro growth regulators does not increase the percentage of seedling emergence, however soaking in a solution of Ethrel at 100 ppm provides higher speed of emergence and root development. Tratamentos pré-germinativos, como a escarificação e o uso de reguladores de crescimento, podem proporcionar a superação de dormência em sementes e incrementar a emergência e o desenvolvimento de plântulas. O objetivo da presente pesquisa foi determinar tratamentos adequados para a superação da dormência de sementes e potencialização do crescimento inicial de plântulas de umbuzeiro. Utilizou-se o delineamento inteiramente casualizado, em fatorial 2 x 4, sendo os fatores: sementes escarificadas ou não escarificadas e, posteriormente, imersas em água ou soluções aquosas de giberelina, citocinina ou etileno, com 4 repetições de 15 sementes. Não houve interação significativa entre os tratamentos escarificação e uso de reguladores de crescimento. A escarificação mecânica e a embebição de sementes de umbuzeiro em soluções contendo reguladores de crescimento não aumenta a percentagem de emergência de plântulas, entretanto a embebição em solução de Ethrel a 100 ppm proporciona maior velocidade de emergência e

  16. Simulating wall and corner fire tests on wood products with the OSU room fire model

    Science.gov (United States)

    H. C. Tran

    1994-01-01

    This work demonstrates the complexity of modeling wall and corner fires in a compartment. The model chosen for this purpose is the Ohio State University (OSU) room fire model. This model was designed to simulate fire growth on walls in a compartment and therefore lends itself to direct comparison with standard room test results. The model input were bench-scale data...

  17. Association between air pollution and ischemic cardiovascular emergency room visits

    International Nuclear Information System (INIS)

    Lin, C.A.; Amador Pereira, L.A.; Souza onceicao, G.M. de; Kishi, H.S.; Milani, Rodolfo; Ferreira Braga, A.L.; Ascimento Saldiva, P.H.

    2003-01-01

    This study observed the relationship between air pollutants and ischemic cardiac diseases such as angina and acute myocardial infarction in a representative cardiovascular center emergency room in Sao Paulo, Brazil. Daily emergency room admissions to the Institute of the Heart of the university of Sao Paulo, as well as data concerning daily air pollutant levels and meteorological variables, were collected from January 1994 to august 1995. Generalized additive Poisson regressions were fitted to the logarithm of the expected values of total emergency room visits due to angina or acute myocardial infarction, controlling for smooth functions of season and weather and indicators for days of the week. All investigated pollutants were positively associated with ischemic cardiovascular disease emergency room visits, and the time lags were relatively short, but only CO presented in effect that was statistically significant. An interquartile range increase n CO was associated with an increase of 6.4% (95% CI: 0.7-12.1) in daily angina or acute myocardial infarction emergency room visits. This result did not change when estimates were done using linear models and natural cubic plines. This study showed that air pollution has a role in cardiovascular morbidity in Sao Paulo, reinforcing the necessity for air pollutant mission-controlling polices in urban areas

  18. The effect of architectural façade design on energy savings in the student dormitory

    Directory of Open Access Journals (Sweden)

    Pejić Petar Č.

    2014-01-01

    Full Text Available There are many reasons for adequate use of natural light inside students' dormitories. Intensity of light required for student activities and temperature inside the rooms are the major factors for an occupant's comfortable work and life. Design of building façades has a significant impact both on the use of natural light and energy consumption. In this paper, a comparative analysis of student rooms with different orientations and different façade designs was performed in order to investigate what type of refurbishment in the façade is necessary. The goal of the refurbishment was generation of optimal thermal and lighting comfort for students' work with maximal energy saving for a new student dormitory in Nis, Serbia. An analysis of annual energy consumption of the newly designed student dormitory and proposed replacements on the exterior façade was performed by using the software EnergyPlus. Based on the energy consumption analysis it could be concluded that significant energy savings would be possible by upgrading the shading devices across the width of the window. In other words, changing the façade of the dorm could generally improve students' comfort, while the energy costs would be reduced. [Projekat Ministarstva nauke Republike Srbije, br. TR 36037: Development of student dorms in Serbia at the beginning of the 21st century i br. TR 33051: The concept of sustainable energy supply of settlements with energy efficient buildings

  19. 8 February 2010: University College London President & Provost M. Grant signing the guest book with CERN Director-General R.Heuer and Coordinator for External Relations F. Pauss; visiting the ATLAS control room with Collaboration Spokesperson F. Gianotti and Adviser for Non-Member States J. Ellis.

    CERN Multimedia

    Maximilien Brice

    2010-01-01

    Caption for photograph 1002015 01: 8 February 2010: University College London President & Provost M. Grant (6th from left) visiting ATLAS control room with, from left to right, ATLAS Deputy Spokesperson and University of Birmingham D. Charlton; UCL Head of the HEP group M. Lancaster; UCL Vice Provost for research D. Price; ATLAS Collaboration Spokesperson F. Gianotti; UCL Department of Physics and Astronomy N. Konstantinidis; UCL Head of Physics Department J. Tennyson; Head of the UCL-ATLAS group and Vice-Dean for Research in the faculty of Mathematical and Physical Sciences J. Butterworth, visiting the ATLAS control room.

  20. Hypoxia Room

    Data.gov (United States)

    Federal Laboratory Consortium — The Hypoxia Room is a 8x8x8 ft. clear vinyl plastic and aluminum frame construction enclosure located within USAREIM laboratory 028. The Hypoxia Room (manufactured...

  1. Effect of Room Ventilation Rates in Rodent Rooms with Direct-Exhaust IVC Systems.

    Science.gov (United States)

    Geertsema, Roger S; Lindsell, Claire E

    2015-09-01

    When IVC are directly exhausted from a rodent housing room, the air quality of the room can become independent of the intracage air quality and may reduce the need for high room ventilation rates. This study assessed the effect of decreasing the ventilation rate in rodent rooms using direct-exhaust IVC systems. The study was conducted over 16 wk and compared conditions in 8 rodent rooms that had ventilation rates of 5 to 6 air changes per hour (ACH) with those in rooms at 10 to 12 ACH. At the low ventilation rate, rooms had higher CO₂ concentrations, higher dew point temperature, and lower particulate levels and spent a greater percentage of time above the temperature set point than did rooms at the high rate. The levels of allergens and endotoxins in room air were the same regardless of the ventilation rate. Differences seen in parameters within cages at the 2 ventilation rates were operationally irrelevant. We detected no total volatile organic compounds in the room that were attributable to ammonia, regardless of the ventilation rate. Clearing the air of ethanol after a spill took longer at the low compared with high rate. However, ethanol clearance was faster at the low rate when the demand-control system was activated than at the high ventilation rate alone. Air quality in the room and in the cages were acceptable with room ventilation rates of 5 to 6 ACH in rodent rooms that use direct-exhaust IVC systems.

  2. Room temperature superconductors

    International Nuclear Information System (INIS)

    Sleight, A.W.

    1995-01-01

    If the Holy Grail of room temperature superconductivity could be achieved, the impact on could be enormous. However, a useful room temperature superconductor for most applications must possess a T c somewhat above room temperature and must be capable of sustaining superconductivity in the presence of magnetic fields while carrying a significant current load. The authors will return to the subject of just what characteristics one might seek for a compound to be a room temperature superconductor. 30 refs., 3 figs., 1 tab

  3. Room acoustics modeling using a point-cloud representation of the room geometry

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    Room acoustics modeling is usually based on the room geometry that is parametrically described prior to a sound transmission calculation. This is a highly room-specific task and rather time consuming if a complex geometry is to be described. Here, a run time generic method for an arbitrary room...... geometry acquisition is presented. The method exploits a depth sensor of the Kinect device that provides a point based information of a scanned room interior. After post-processing of the Kinect output data, a 3D point-cloud model of the room is obtained. Sound transmission between two selected points...... level of user immersion by a real time acoustical simulation of a dynamic scenes....

  4. TUGAS ROOM ATTENDANT DALAM MENANGANI COMPLAINT TAMU DELUXE ROOM HOTEL HYAAT REGENCY BANDUNG

    Directory of Open Access Journals (Sweden)

    Reza Gustia Purnama

    2016-05-01

    Full Text Available Abstract - The problem is how meticulous the duties and responsibilities of the room attendant in the deluxe room Hotel Hyatt Regency Bandung, standard operational procedures in the deluxe room Hotel Hyatt Regency Bandung, and handling guest complaint in deluxe room Hotel Hyatt Regency Bandung. Author uses descriptive analysis, which is a form of writing in the actual situation describes strive about the object of research, then the data obtained in the form of a report compiled in. Based on the results of observation it can be concluded that the task and responsibility of the room attendant in the deluxe room Hyatt Regency Bandung already carry it out in accordance with standard operational procedures (SOP which is divided into two shifts, morning and evening shift which has a slightly different task, standard operational procedures in the deluxe room Hyatt Regency Bandung has been standard operating procedure in applying it at the hotel Hyatt Regency Bandung, and Guest complaint handling in deluxe room Hyatt Regency Bandung Hotel how to deal with and resolve the complaint vary slightly in view of the type of complaint. Based on the results of observation and discussion, the authors conclude that the Duty room attendant in handling customers compaint deluxe room in the Hyatt Regency Bandung Hotel when his handlers was conducted appropriately and propesional effects will be good for the image of the hyatt regency hotel bandung.   Keywords: Room Attendant, Complaint, Deluxe room   Abstraksi - Masalah yang di teliti adalah tugas dan tanggung jawab room attendant di deluxe room Hotel Hyatt Regency Bandung, standar operasional prosedur di deluxe room Hotel Hyatt Regency Bandung, dan penanganan complaint tamu di deluxe room Hotel Hyatt Regency Bandung.  Metode yang di gunakan menggunakan analisis deskriptif, yaitu bentuk penulisan yang di upayakan menggambarkan keadaan yang sebenarnya tetang objek penelitian,kemudian data yang di peroleh disusun

  5. Superação da dormência de cultivares de mirtileiro em ambiente protegido com cianamida hidrogenada e óleo mineral

    Directory of Open Access Journals (Sweden)

    Roberto Coletti

    2011-06-01

    Full Text Available O mirtileiro é uma frutífera de clima temperado que necessita de frio no outono/inverno. A insuficiência de frio pode provocar deficiente e desuniforme brotação e floração, com reflexos na produção. A pesquisa realizada na Universidade de Passo Fundo-RS, teve por objetivo estudar a superação da dormência de cultivares de mirtileiro (Georgiagem, Climax e Aliceblue em ambiente protegido, tratadas em 25-07-2007 com cianamida hidrogenada (CH, nas doses de 0,52% e 1,04% (1% e 2% do produto comercial Dormex®, com a adição de 0,5% de óleo mineral (OM, comparando com plantas sem tratamento. As plantas encontravam-se no terceiro ciclo vegetativo e no primeiro de produção. O plantio foi realizado em 2005, no espaçamento de 0,7 m x 2,0 m, com irrigação por gotejamento. De acordo com os resultados obtidos, a aplicação no final de julho de CH + OM concentrou e uniformizou a floração e antecipou a brotação das cvs. Georgiagem e Clímax. A cianamida hidrogenada, nas concentrações de 0,52% e 1,04% (1% e 2% de Dormex®, combinado com 0,5% de óleo mineral, não teve efeito na porcentagem de brotação, mas reduziu a produção, evidenciando efeitos fitotóxicos.

  6. STS-93 M.S. Michel Tognini in white room

    Science.gov (United States)

    1999-01-01

    STS-93 Mission Specialist Michel Tognini of France is checked out by white room closeout crew members before entering the orbiter Columbia. Tognini is with the Centre National d'Etudes Spatiales (CNES). The white room is an environmental chamber at the end of the orbiter access arm that provides entry to the orbiter crew compartment. STS-93 is a five-day mission primarily to release the Chandra X-ray Observatory, which will allow scientists from around the world to study some of the most distant, powerful and dynamic objects in the universe. After Space Shuttle Columbia's July 20 and 22 launch attempts were scrubbed, the launch was again rescheduled for Friday, July 23, at 12:24 a.m. EDT. The target landing date is July 27 at 11:20 p.m. EDT.

  7. International Business Potential for Analytics of Room Utilization

    OpenAIRE

    Binde, Karl Bernhoff

    2015-01-01

    Many universities worldwide have large campuses which they are trying to maintain and administer in the best way possible. Their infrastructure often includes numerous auditoriums with access to the Internet by the Wi-Fi standard. MazeMap and Cisco have developed a solution which can geographically track Wi-Fi clients within a building. This solution makes it possible to count the number of people in a room through depersonalized data. On an international level, the student numbers are increa...

  8. LOW ENDOPHTHALMITIS RATES AFTER INTRAVITREAL ANTI-VASCULAR ENDOTHELIAL GROWTH FACTOR INJECTIONS IN AN OPERATION ROOM

    DEFF Research Database (Denmark)

    Freiberg, Florentina J; Brynskov, Troels; Munk, Marion R

    2017-01-01

    PURPOSE: To evaluate the rate of presumed endophthalmitis (EO) after intravitreal anti-vascular endothelial growth factor (anti-VEGF) injections in three European hospitals performed in an operation room (OR) under sterile conditions. METHODS: A retrospective multicenter study between 2003 and 2016...... at three European sites, City Hospital Triemli Zurich, Switzerland (CHT), Zealand University Hospital Roskilde, Denmark (ZUH) and University Clinic Bern, Switzerland (UCB). Intravitreal injection (IVI) database of each department was reviewed. All anti-vascular endothelial growth factor injections were...... performed using a standardized sterile technique in an operation room. Injection protocols were similar between the three sites. No preinjection antibiotics were given. Postoperative antibiotics varied among sites. RESULTS: A total of 134,701 intravitreal injections were performed at the 3 sites between...

  9. RESIKO PENULARAN INFEKSI DI RUANG AUTOPSI DAN PENERAPAN KEWASPADAAN UNIVERSAL

    Directory of Open Access Journals (Sweden)

    Citra Manela

    2015-12-01

    Full Text Available AbstrakPeningkatan resiko penularan infeksi di ruang autopsi semakin meningkat. Hal ini terjadi karena peningkatan jumlah kasus korban meninggal yang terinfeksi penyakit terutama di negara berkembang. Beberapa studi menyatakan terjadinya peningkatan prevalensi HIV, hepatitis B, C, D dan G, tuberkulosis, penyakit Prion, Hantavirus, campak, infeksi bakteri atau HTCV pada pekerja di ruang autopsi. Penerapan kewaspadaan universal, termasuk standar OSHA, pemilihan disinfektan dan pengolahan limbah medis sangat penting diperhatikan untuk mencegah resiko terjadinya penularan infeksi. Tujuan penulisan tinjauan pustaka ini adalah mengetahui risiko penularan infeksi pada pekerja di ruang autopsi dan penerapan kewaspadaan universal. Penulisan ini berdasarkan studi kepustakaan yang terkait dengan dua topik ini. Penerapan kewaspadaan universal sangat diperlukan dalam pencegahan penularan penyakit infeksi pada pekerja di ruang autopsi yaitu meliputi penggunaan alat pelindung diri yang tepat, perilaku, tindakan mencegah infeksi, disinfeksi dan penanganan sampah medis yang sesuai aturan.AbstractThe risk of infection transmissions in autopsy room is increasing. This happens because the increase of the number of cases died affected by infectious disease, especially in developing countries. Several studies found an increase on the prevalence of HIV , Hepatitis B , C , D and G, Tuberculosis , Prion Disease , Hantavirus , Measles , Bacterial Infection or HTCV on workers in autopsy room .The application of universal precaution , including OSHA standards , the selection of disinfectant, medical waste management is very important to prevent the risk of the infection transmission. The aim of this review was to explain the risks of infection transmissions on workers in autopsy room and the application of universal precaution. Literatures on these two topics were evaluated. Application of universal precautions are very necessary in the prevention of transmission of

  10. Control room philosophy: Principles of control room design and control room work; Kontrollrumsfilosofi: Principer foer kontrollrumsutformning och kontrollrumsarbete

    Energy Technology Data Exchange (ETDEWEB)

    Skriver, Jan; Ramberg, Jasmine; Allwin, Pernilla [Scandpower Risk Management AB, Uppsala (Sweden)

    2006-01-15

    In order to provide insights for improvement of work in control rooms several factors have to be considered. Knowledge of principles including control room philosophies will guide the recommended improvements. In addition to knowledge about specific principles an advantage for an organization can be an understanding of similarities and policies used in other high risk industry. The report has been developed on the basis of a document analysis of international standards and other guiding documents. (NUREG 0711, ISO 11064, ISO 6385, IEC 60964). In addition to the document analysis which has strived to compare the documents to see similarities in important principals, experience from working with control room design, modifications and evaluations in other high risk industries has pervaded the report. Important principles have been identified which are recommended to be included in a control room philosophy. Many of these are similar to the principles identified in the international standards. An additional principal which is regarded as important is the utilization of Key Performance Indicators (KPI) which can be used as a measure to target preventative means. Further more it is critical that the control room philosophy is easy to access and comprehend for all users. One of the challenges that remain after having developed a control room philosophy is how to utilize it in the daily work situation. It is vital that the document remains as a living document, guiding the continual improvement of the control room in the various life cycle stages.

  11. Reliability of estimating the room volume from a single room impulse response

    OpenAIRE

    Kuster, M.

    2008-01-01

    The methods investigated for the room volume estimation are based on geometrical acoustics, eigenmode, and diffuse field models and no data other than the room impulse response are available. The measurements include several receiver positions in a total of 12 rooms of vastly different sizes and acoustic characteristics. The limitations in identifying the pivotal specular reflections of the geometrical acoustics model in measured room impulse responses are examined both theoretically and expe...

  12. Nitrous oxide levels in operating and recovery rooms of Iranian hospitals.

    Science.gov (United States)

    Maroufi, Sh Sadigh; Gharavi, Mj; Behnam, M; Samadikuchaksaraei, A

    2011-01-01

    Nitrous oxide (N(2)O) is the oldest anesthetic in routine clinical use and its occupational exposure is under regulation by many countries. As studies are lacking to demonstrate the status of nitrous oxide levels in operating and recovery rooms of Iranian hospitals, we aimed to study its level in teaching hospitals of Tehran University of Medical Sciences. During a 6-month period, we have measured the shift-long time weighted average concentration of N(2)O in 43 operating and 12 recovery rooms of teaching hospitals of Tehran University of Medical Sciences. The results show that the level of nitrous oxide in all hospitals is higher than the limits set by different countries and anesthetists are at higher risk of exposure. In addition, it was shown that installation of air ventilation could reduce not only the overall exposure level, but also the level of exposure of anesthetists in comparison with other personnel. The high nitrous oxide level in Iranian hospitals necessitates improvement of waste gas evacuation systems and regular monitoring to bring the concentration of this gas into the safe level.

  13. Efficiency of hydrogen peroxide in improving disinfection of ICU rooms.

    Science.gov (United States)

    Blazejewski, Caroline; Wallet, Frédéric; Rouzé, Anahita; Le Guern, Rémi; Ponthieux, Sylvie; Salleron, Julia; Nseir, Saad

    2015-02-02

    The primary objective of this study was to determine the efficiency of hydrogen peroxide (H₂O₂) techniques in disinfection of ICU rooms contaminated with multidrug-resistant organisms (MDRO) after patient discharge. Secondary objectives included comparison of the efficiency of a vaporizator (HPV, Bioquell) and an aerosolizer using H₂O₂, and peracetic acid (aHPP, Anios) in MDRO environmental disinfection, and assessment of toxicity of these techniques. This prospective cross-over study was conducted in five medical and surgical ICUs located in one University hospital, during a 12-week period. Routine terminal cleaning was followed by H₂O₂ disinfection. A total of 24 environmental bacteriological samplings were collected per room, from eight frequently touched surfaces, at three time-points: after patient discharge (T0), after terminal cleaning (T1) and after H₂O₂ disinfection (T2). In total 182 rooms were studied, including 89 (49%) disinfected with aHPP and 93 (51%) with HPV. At T0, 15/182 (8%) rooms were contaminated with at least 1 MDRO (extended spectrum β-lactamase-producing Gram-negative bacilli 50%, imipenem resistant Acinetobacter baumannii 29%, methicillin-resistant Staphylococcus aureus 17%, and Pseudomonas aeruginosa resistant to ceftazidime or imipenem 4%). Routine terminal cleaning reduced environmental bacterial load (P disinfection efficiency.

  14. Patient safety in the operating room: an intervention study on latent risk factors

    Directory of Open Access Journals (Sweden)

    van Beuzekom Martie

    2012-06-01

    Full Text Available Abstract Background Patient safety is one of the greatest challenges in healthcare. In the operating room errors are frequent and often consequential. This article describes an approach to a successful implementation of a patient safety program in the operating room, focussing on latent risk factors that influence patient safety. We performed an intervention to improve these latent risk factors (LRFs and increase awareness of patient safety issues amongst OR staff. Methods Latent risk factors were studied using a validated questionnaire applied to the OR staff before and after an intervention. A pre-test/post-test control group design with repeated measures was used to evaluate the effects of the interventions. The staff from one operating room of an university hospital acted as the intervention group. Controls consisted of the staff of the operating room in another university hospital. The outcomes were the changes in LRF scores, perceived incident rate, and changes in incident reports between pre- and post-intervention. Results Based on pre-test scores and participants’ key concerns about organizational factors affecting patient safety in their department the intervention focused on the following LRFs: Material Resources, Training and Staffing Recourses. After the intervention, the intervention operating room - compared to the control operating room - reported significantly fewer problems on Material Resources and Staffing Resources and a significantly lower score on perceived incident rate. The contribution of technical factors to incident causation decreased significantly in the intervention group after the intervention. Conclusion The change of state of latent risk factors can be measured using a patient safety questionnaire aimed at these factors. The change of the relevant risk factors (Material and Staffing resources concurred with a decrease in perceived and reported incident rates in the relevant categories. We conclude that

  15. Temperaturas efetivas para a dormência da macieira(Malus domestica Borkh Effective temperatures for apple tree dormancy (Malus domestica Borkh

    Directory of Open Access Journals (Sweden)

    Gilberto Luiz Putti

    2003-08-01

    Full Text Available As cultivares de macieira exigem diferentes requerimentos em frio, ou seja, o total de horas abaixo de um limite de temperatura do ar, porém são poucas as informações sobre quais temperaturas são mais eficientes para superar a dormência. As cultivares de macieira Condesa, Baronesa, Daiane, Imperatriz, Fuji e Gala foram estudadas quanto à quantidade de frio e as temperaturas do ar para a indução da brotação. O delineamento experimental foi o inteiramente casualizado, no esquema fatorial, com seis cultivares, cinco níveis de unidades de frio ( 300; 600; 900; 1200 e 1500 UF e três temperaturas do ar ( 5; 10 e 15ºC. O tempo médio para brotação foi menor quando as cultivares foram submetidas a 1.500 unidades de frio, independentemente da temperatura. A temperatura efetiva para acumular frio varia com a cultivar, podendo chegar até 15ºC para cultivares de menor exigência em frio.Apple tree cultivars demand several requirements in cold but there's a little of information about what temperatures are the most efficient. Apple tree cultivars Condesa, Baronesa, Daiane, Imperatriz, Fuji and Gala were studied on quantity of cold and different temperatures for shooting inducement. Experimental delineation was full casualized on the factorial system, with six cultivars, five levels of cold unities and three temperatures. Average time for shooting was minor when the cultivars were exposed to 1,500 cold unities independently of the temperature. Effective temperature in order to accumulate cold ranges according to the cultivar, and it is able reaching until 15ºC in case of cultivar of lower demand in cold.

  16. Future control room design (modernization of control room systems)

    International Nuclear Information System (INIS)

    Reischl, Ludwig; Freitag, Timo; Dergel, Rene

    2009-01-01

    In the frame of lifetime extension for nuclear power plants the modernization of the complete safety and operational control technology will be digitalized. It is also recommended to modernize the operator facilities, monitoring systems in the control room, the back-up shut-down center and the local control stations. The authors summarize the reasons for the modernization recommendations and discuss possible solutions for display-oriented control rooms. A concept for control room backfitting includes generic requirements, requirements of the local authorities, ergonomic principles information content and information density, and the design process. The backfitting strategy should include a cooperation with the operational personnel, The quality assurance and training via simulator needs sufficient timing during the implementation of the backfitting.

  17. Survivability of boar sperm stored under room temperature in extenders containing some natural products

    OpenAIRE

    Machebe,; Ugwu,Simeon; Akandi,Alafuro

    2015-01-01

    Alafuro Akandi,1 Simeon Ogochukwu Ugwu,1 Ndubuisi Samuel Machebe,1,2 1Department of Animal Science, University of Nigeria, Nsukka, Nigeria; 2Laboratory of Animal Reproduction, College of Agriculture, Kinki University, Nara, Japan Background: Semen extenders are used to create multiple insemination doses from a single ejaculate and contain buffers and nutrients suitable for storage of spermatozoa. The purpose of this study was to evaluate the survivability of boar sperm stored under room temp...

  18. Influence of various room parameters upon radon daughter equilibrium indoors

    International Nuclear Information System (INIS)

    Islam, G.S.; Mazumdar, S.C.; Ashraf, M.A.

    1995-06-01

    The parameters such as ventilation rate, attachment rate to aerosols and deposition processes, which influence the radon daughter equilibrium indoors, are discussed and the validity of the theoretical model checked by experiments. In agreement with the model calculations, the experimental data show, that the equilibrium factor F in rooms is mainly influenced by the rate of attachment to aerosols and the plateout of radon daughters. The equilibrium factor varies between 0.3 and 0.4 at an attachment rate of 300 h -1 . The influence of ventilation upon the free fraction of RaA( 218 Pp)-atoms is also investigated. This is in good agreement with the results of the measurements carried out in different types of rooms at the University Campus of Rajshahi. (author). 20 refs, 3 figs, 3 tabs

  19. Assess of the Status of the Karaj Operating Rooms in Comparison with International Standards in 2011

    Directory of Open Access Journals (Sweden)

    M.H. Naseri

    2012-10-01

    Full Text Available Background: Because of making money, the operating room (OR is known as the beating heart of any clinical & health center. The effective and regular activity of the operating room guarantees a sustainable income for the hospital. So, in order to provide high quality treatment and care services, and to save the health and safety of OR staff, exploiting standard equipments and spaces as well as employing professional and skilled personnel is necessary. This study was aimed to assess the status of the Karaj operating rooms from physical, safety, sterilization, staffing and equipment aspects in comparison to the International Standards. Methods: This sectional descriptive study was conducted in Alborz University of Medical Sciences in 2011. Samples were 10 operating room wards from 10 surgical hospitals. Data were collected by a 70 items check-list at 5 fields of physical, safety, sterilization, staffing and equipment conditions and then compared to the international standards. The data were recorded in SPSS software and analyzed by statistical methods. Results: The results showed that compared to the international standards, the physical aspect was 60.5%, safety aspect 66%, sterilization aspect 68%, staffing aspect 63%, and equipment aspect was 80% close to the standard criteria. On the whole, in 10 assessed hospitals, equipment aspect with 80% had the best and the physical aspect with 60.5% had the worst conditions respectively. Conclusion: Due to admission in different medical and paramedical programs in Alborz University of Medical Sciences, renovation of the ORs is essential for training skilled students. Considering the results of this study could help the University authorities to improve the current condition.

  20. Controlling the clean room atmosphere

    International Nuclear Information System (INIS)

    Meeks, R.F.

    1979-01-01

    Several types of clean rooms are commonly in use. They include the conventional clean room, the horizontal laminar flow clean room, the vertical laminar flow clean room and a fourth type that incorporates ideas from the previous types and is known as a clean air bench or hood. These clean rooms are briefly described. The origin of contamination and methods for controlling the contamination are discussed

  1. Disinfection of indoor air microorganisms in stack room of university library using gaseous chlorine dioxide.

    Science.gov (United States)

    Hsu, Ching-Shan; Lu, Ming-Chun; Huang, Da-Ji

    2015-02-01

    As with all indoor public spaces in Taiwan, the stack rooms in public libraries should meet the air quality guidelines laid down by the Taiwan Environmental Protection Administration. Accordingly, utilizing a university library in Taiwan for experimental purposes, this study investigates the efficiency of gaseous chlorine dioxide (ClO2) as a disinfection agent when applied using three different treatment modes, namely a single-daily disinfection mode (SIM), a twice-daily disinfection mode (TWM), and a triple-daily disinfection mode (TRM). For each treatment mode, the ClO2 is applied using an ultrasonic aerosol device and is performed both under natural lighting conditions and under artificial lighting conditions. The indoor air quality is evaluated before and after each treatment session by measuring the bioaerosol levels of bacteria and fungi. The results show that for all three disinfection modes, the application of ClO2 reduces the indoor bacteria and fungi concentrations to levels lower than those specified by the Taiwan EPA (i.e., bacteria <1500 CFU/m(3), fungi <1000 CFU/m(3)), irrespective of the lighting conditions under which the disinfection process is performed. For each disinfection mode, a better disinfection efficiency is obtained under natural lighting conditions since ClO2 readily decomposes under strong luminance levels. Among the three treatment modes, the disinfection efficiencies of the TWM and TRM modes are very similar under natural lighting conditions and are significantly better than that of the SIM mode. Thus, overall, the results suggest that the TWM treatment protocol represents the most cost-effective and efficient method for meeting the indoor air quality requirements of the Taiwan EPA.

  2. Building baby universes

    Science.gov (United States)

    Coles, Peter

    2017-08-01

    The thought of a scientist trying to design a laboratory experiment in which to create a whole new universe probably sounds like it belongs in the plot of a science-fiction B-movie. But as author Zeeya Merali explains in her new book A Big Bang in a Little Room, there are more than a few eminent physicists who think that this is theoretically possible.

  3. Room Acoustical Fields

    CERN Document Server

    Mechel, Fridolin

    2013-01-01

    This book presents the theory of room acoustical fields and revises the Mirror Source Methods for practical computational use, emphasizing the wave character of acoustical fields.  The presented higher methods include the concepts of “Mirror Point Sources” and “Corner sources which allow for an excellent approximation of complex room geometries and even equipped rooms. In contrast to classical description, this book extends the theory of sound fields describing them by their complex sound pressure and the particle velocity. This approach enables accurate descriptions of interference and absorption phenomena.

  4. ATLAS virtual visit features Birzeit University, first university in Palestine and a member of the International Association of Universities since 1977.

    CERN Multimedia

    claudia marcelloni

    2012-01-01

    This ATLAS virtual visit features Birzeit University, first university in Palestine and a member of the International Association of Universities since 1977. As part of the "Physics Without Frontiers" project, funded by the International Centre for Theoretical Physics (ICTP), Birzeit is hosting a one day particle physics masterclass. During the day the physics major students are given an introduction to experimental particle physics, the LHC and the ATLAS Experiment, before having the chance to analyze real LHC data. This virtual visit comprises of a live tour around the ATLAS control room and the opportunity to ask questions to the ATLAS physicists. The Department of Physics at Birzeit University provides an exciting environment for the training of both graduate and undergraduate students. Some of the Physics department graduates participated in the CERN Summer Program over the past few years.

  5. Virtual Seminar Room

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Fosgerau, Anders; Hansen, Peter Søren Kirk

    1999-01-01

    The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented.......The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented....

  6. Submicron Particle-Bound Mercury in University Teaching Rooms: A Summer Study from Two Polish Cities

    Directory of Open Access Journals (Sweden)

    Grzegorz Majewski

    2016-09-01

    Full Text Available The goal of the study was to determine the concentrations of submicron particulate matter (PM1 and of the mercury contained in it (Hgp in the air in two teaching rooms in two Polish cities, Gliwice and Warsaw. The levels of atmospheric particulate matter (PM differ greatly between these two cities. The relations between the indoor (I and outdoor (O 24-h concentrations for each PM1 and Hgp were determined and, based on the conclusions, an attempt was made to identify the main sources of the indoor Hgp in both cities. During the whole measuring period (April–June 2015, in both Warsaw and Gliwice, the 24-h outdoor PM1 concentrations were slightly higher than the indoor ones (outdoor and indoor averages were equal to 19.3 µg m−3 and 14.5 µg·m−3, respectively, in Gliwice and to 13.2 µg·m−3 and 9.5 µg·m−3 in Warsaw. In Gliwice, the indoor concentrations of Hgp (2.4 pg·m−3 to 27.7 pg·m−3 were much higher than the outdoor ones (1.1 pg·m−3 to 6.1 pg·m−3; in Warsaw the average concentrations of Hgp were equal to 1.4 pg m−3 indoors and outdoors. The 24-h concentrations of Hgp and the 24-h I/O ratios for Hgp varied more intensely in Gliwice than in Warsaw throughout the whole measuring period. In Warsaw, the teaching room Hgp came mainly from the infiltration of atmospheric (outdoor Hgp. In Gliwice, a part of the indoor Hgp infiltrated into the teaching room with the outdoor PM1 that most probably was then enriched with gaseous indoor Hg, what resulted in the relatively high indoor Hgp concentrations.

  7. STS-93 M.S. Stephen Hawley in the White Room

    Science.gov (United States)

    1999-01-01

    STS-93 Mission Specialist Stephen A. Hawley (Ph.D.) is checked out by white room closeout crew members before entering the orbiter Columbia. In the background is Mission Specialist Michel Tognini of France, waiting to enter Columbia. The white room is an environmental chamber at the end of the orbiter access arm that provides entry to the orbiter crew compartment. STS-93 is a five-day mission primarily to release the Chandra X-ray Observatory, which will allow scientists from around the world to study some of the most distant, powerful and dynamic objects in the universe. After Space Shuttle Columbia's July 20 and 22 launch attempts were scrubbed, the launch was again rescheduled for Friday, July 23, at 12:24 a.m. EDT. The target landing date is July 27 at 11:20 p.m. EDT.

  8. The elephant in the prayer room. Exploring the non/ephemeral effects of racialized atmospheres and mood politics

    DEFF Research Database (Denmark)

    Staunæs, Dorthe; Hvenegaard-Lassen, Kirsten

    The elephant in the prayer-room. Exploring the non/ephemeral effects of racialized atmospheres and mood politics by Kirsten Hvenegård-Lassen, kirs@ruc.dk and Dorthe Staunæs dost@edu.au.dk In this paper, we zoom in on atmosphere and mood politics in order to discuss the dismissal of race and racism...... in a Danish context. We use the recent debate in the Danish Parliament concerning a state ban on “prayer-rooms” or multifaith-rooms in educational institutions as our point of departure. The now retired Vice-chancellor of Copenhagen University, declared that banning prayer-rooms was an example of what he...... in these debates. The naming of the prayer-room ban as ‘mood politics’ is worth pursuing: how is it that race matters become ephemeral and perhaps atmospheric? (Ahmed, 2014). We read the debate diffractively through the metaphor The elephant in the room (Barad, 2007; Haraway, 1997). This metaphor hints towards...

  9. Measuring quality indicators in the operating room: cleaning and turnover time.

    Science.gov (United States)

    Jericó, Marli de Carvalho; Perroca, Márcia Galan; da Penha, Vivian Colombo

    2011-01-01

    This exploratory-descriptive study was carried out in the Surgical Center Unit of a university hospital aiming to measure time spent with concurrent cleaning performed by the cleaning service and turnover time and also investigated potential associations between cleaning time and the surgery's magnitude and specialty, period of the day and the room's size. The sample consisted of 101 surgeries, computing cleaning time and 60 surgeries, computing turnover time. The Kaplan-Meier method was used to analyze time and Pearson's correlation to study potential correlations. The time spent in concurrent cleaning was 7.1 minutes and turnover time was 35.6 minutes. No association between cleaning time and the other variables was found. These findings can support nurses in the efficient use of resources thereby speeding up the work process in the operating room.

  10. Guidelines for control room design reviews

    International Nuclear Information System (INIS)

    1981-09-01

    The control room design review is part of a broad program being undertaken by the nuclear industry and the government to ensure consideration of human factors in nuclear power plant design and operation. The purpose of the control room design review described by these guidelines is to (1) review and evaluate the control room workspace, instrumentation, controls, and other equipment from a human factors engineering point of view that takes into account both system demands and operator capabilities; and (2) to identify, assess, and implement control room design modifications that correct inadequate or unsuitable items. The scope of the control room design review described by these guidelines covers the human engineering review of completed control rooms; i.e., operational control rooms or those at that stage of the licensing process where control room design and equipment selection are committed. These guidelines should also be of use during the design process for new control rooms. However, additional analyses to optimize the allocation of functions to man and machine, and further examination of advanced control system technology, are recommended for new control rooms. Guidelines and references for comprehensive system analyses designed to incorporate human factors considerations into the design and development of new control rooms are presented in Appendix B. Where possible, a generic approach to the control room design review process is encouraged; for example, when control room designs are replicated wholly or in part in two or more units. Even when designs are not replicated exactly, generic reviews which can be modified to account for specific differences in particular control rooms should be considered. Industry organizations and owners groups are encouraged to coordinate joint efforts and share data to develop generic approaches to the design review process. The control room design review should accomplish the following specific objectives. To determine

  11. Superação de dormência na qualidade de sementes e mudas: influência na produção de Senna multijuga (L. C. Rich. Irwin & Barneby Overcoming of dormancy in the quality of seeds and seedlings: influence in the production of Senna multijuga (L.C. Rich. Irwin & barneby

    Directory of Open Access Journals (Sweden)

    Graziela Piveta

    2010-01-01

    Full Text Available O objetivo deste trabalho foi determinar a qualidade fisiológica e sanitária de sementes de Senna multijuga(L. C. Rich. Irwin & Barneby relacionada aos métodos de superação de dormência e à interferência na produção de mudas. As sementes foram submetidas aos seguintes métodos: imersão em água fervente, as sementes foram imersas em água, com temperatura de 100°C, até esfriar, por 24 horas; escarificação ácida, onde as sementes foram imersas em ácido sulfúrico (H2SO4 a 90%, por 10 e 20 minutos, e testemunha (sem tratamento. Foram realizados os testes de sanidade, germinação, tetrazólio e avaliação da qualidade das mudas. O delineamento experimental foi inteiramente casualizado. Para a avaliação da germinação foi utilizado um esquema fatorial (4 X 2, com quatro métodos de superação de dormência X dois fotoperíodos, para os substratos rolo-de-papel e vermiculita. A escarificação ácida constituiu-se no método mais eficiente para a superação da dormência das sementes de Senna multijuga. Penicillium sp. e Aspergillus sp. tiveram sua incidência aumentada quando o tegumento foi danificado pela escarificação ácida por 20 minutos. O controle de Fusarium spp. aumentou gradativamente com o aumento do tempo de exposição ao ácido sulfúrico.The objective of this work was to determine the physiological and sanitary quality of Senna multijugaseeds related to the methods of dormancy overcoming and the influence on the seedlings quality. The seeds had been submitted to the following methods :immersion in water fervent, the seeds had been immersed in water, at 100°C, until cooling for 24 hours; acid escarification, where the seeds had been immersed in sulfuric acid (H2SO4 90%, for 10 and 20 minutes, and control (without treatment. The tests of sanity, germination and tetrazolium had been carried through, and were evaluated the quality of the seedlings. For the germination of the evaluation an factorial project was

  12. POLITENESS STRATEGIES EMPLOYED BY THE TRAINERS IN ROOM DIVISION DEPARTMENT BAPEPAR NUSA DUA

    Directory of Open Access Journals (Sweden)

    I Gusti Ayu Vina Widiadnya Putri

    2017-05-01

    Full Text Available This article tries to analyze and discuss the politeness strategies employed by the trainers in room division department when they practice on the job training in the hotel. Politeness strategy was needed when the trainers serve the guest. This research was done by observation and interview with the trainer and the guest about their conversation. The analysis of politeness strategies that employed by the trainer focused on two discussions; (1 the kinds of politeness strategies used by trainer in room division department, and (2 the implications of politeness strategies used by trainer in room division department. This research used the theory from Brown & Levinson (1987 in his book entitled Politeness: Some Universals in Language Usages. The theory is supported by other theories that are considered relevant to the topic of discussion in this research. Based on the analysis, it was found that there were two kinds of politeness stratgies that employed by the trainer in room division department Bapepar Nusa Dua, they were positive face and negative face. Beside that, there are three implications by using politness strategies such as: respect behaviour, togheterness, and cooperative interaction.

  13. Validity of building characteristics and dorm dampness obtained in a self-administrated questionnaire

    DEFF Research Database (Denmark)

    Sun, Y.X.; Sundell, Jan; Zhang, Y.F.

    2007-01-01

    status), while such problems observed by inspectors were not. The air relative humidity was slightly higher, during winter time, in rooms with condensation on windowpanes. The results indicate that questionnaire surveys give valid data regarding most technical characteristics. With regard to moisture...... characteristics, such as type of surface materials etc., but a poor to slight agreement (kappamoisture damages, such as mould or damp spots, and a mouldy smell, between occupants and inspectors. Dampness problems reported by occupants were associated with health effects (case...

  14. Superação da dormência de sementes de umbuzeiro (Spondias tuberosa, Arr. Câm. utilizando diferentes métodos Overcoming dormancy of 'umbuzeiro' seeds (Spondias tuberosa, Arr. Câm. by using different methods

    Directory of Open Access Journals (Sweden)

    Paulo Sérgio Nascimento Lopes

    2009-09-01

    Full Text Available Vários frutos de espécies nativas da região semiárida possuem grande potencial de comercialização, dentre eles destaca-se o umbuzeiro (Spondias tuberosa, Arr. Câmara. Entretanto, cultivos comerciais desta espécie são limitados pela dificuldade da obtenção de mudas, em função principalmente da dormência de suas sementes. Desta forma, o objetivo do presente estudo foi avaliar os métodos de superação de dormência da semente de umbuzeiro, visando a promover incrementos nas taxas de germinação, uniformidade e vigor das plântulas. Foram montados dois experimentos independentes. Os tratamentos do primeiro experimento foram: testemunha, imersão dos pirênios em água por 24 horas, imersão dos pirênios em solução de ácido giberélico com 1.000 mg/L por 24 horas, escarificação dos pirênios com ácido sulfúrico PA por 10 minutos e escarificação mecânica. No segundo experimento, os tratamentos consistiram em se plantar os pirênios com 0; 30; 60; 90; 120; 150; 180 e 210 dias de armazenados em sacos de papel sob condições de laboratório, a uma temperatura média de 22,5C° e umidade relativa do ar média de 65%. No primeiro estudo, constatou-se que houve efeito significativo dos métodos de superação de dormência, sendo que escarificação mecânica foi o que apresentou os melhores resultados, com uma taxa de germinação média aos 60 dias pós-plantio de 26,6%. Já no segundo, as sementes armazenadas influenciaram positivamente na germinação e no vigor da plântula. Os melhores resultados para uniformidade e porcentagem de germinação (83% foram obtidos entre 120 e 210 dias de armazenamento das sementes, enquanto para o comprimento e massa fresca da radícula e hipocótilo foram entre 120 e 150 dias.Several fruits of native species of semi-arid region have great potential for commercialization, and among them there is the Spondias tuberosa. However, commercial cultivation of this species is limited by the

  15. Management responsible for the radioactive waste in the University of Costa Rica

    International Nuclear Information System (INIS)

    Mora, P.; Varela, A.

    2003-01-01

    Through the University Plan de Seguridad Radiologica (PSR), established in 1990, radioactive wastes generated by the University of Costa Rica (UCR) personnel are handled. They are properly collected, stroraged and disposed. The waste room is used by the following centers: Laboratorio de Fisica Nuclear Aplicada, Instituto de Investigaciones en Salud, Centro de Biologia Celular y Molecular and Centro de Investigaciones en Contaminacion Ambiental. The PSR has prestorage procedures, internal controls inside the waste room, protocols for storage, withdraw of sources, and discharges to the environment according to national and international legislation. The main radioactive wastes in liquid or solid forms contain p 32 , I 125 , S 35 y C 14 that eventually be disposed as excempted materials. The waste room stores sources with the following radionuclides Cs 137 , U 238 , Th 232 , Sr 90 , Ra 226 , Cd 109 , Cf 252 and Am 241 . It has 96 permanent sources and 52 that will be disposed. The PSR allows the University to have a centralized facility for the safe management of all radioactive waste generated locally. (Author) [es

  16. CSN's New Emergency Room

    International Nuclear Information System (INIS)

    Sendin, P.

    2005-01-01

    During the month of July 2005 the physical renovation works and technological updating of the basic infrastructures of the CSN Emergency Room (SALEM) were finished, allowing the Room to now have greater functionality and a broader technical capacity. Nevertheless, the technological improvement process of SALEM will reach its full potential within the next few years, once the installation currently underway of the new information integration and monitoring systems and the decision making support systems have been completed. This article describes the improvements introduced to the Room and the objectives pursued in this renovation project to convert the SALEM into a new generation room in accordance with its current technological context. (Author) 4 refs

  17. Our Urban Living Room

    DEFF Research Database (Denmark)

    Hjortshøj, Rasmus

    2016-01-01

    Our Urban Living Room is an exhibition and a book, created by Cobe. The theme is based on Cobe’s ten years of practice, grounded in social livability and urban democracy, and our aim to create buildings and spaces that invite Copenhageners to use and define them; as an extended living room, where...... the boundaries between private and public space become fluid. Based on specific Cobe projects, Our Urban Living Room tells stories about the architectural development of Copenhagen, while exploring the progression of the Danish Capital - from an industrial city into an urban living room, known as one...... of the world’s most livable places. Photography by Rasmus Hjortshøj....

  18. Gas explosion in a room with a window and passage to an adjacent room

    Directory of Open Access Journals (Sweden)

    Polandov Yuri

    2016-01-01

    Full Text Available Some publications describe an effect, produced during a physical model experiment, when an adjacent gas-free room influences the gas explosion pressure in a room with a window. The explosion pressure in this case significantly exceeds (2.5 times the explosion pressure in a room without an adjacent room. This result has been confirmed by our studies. Based on other available information about the influence of the ignition point location on the explosion pressure in one room, it was suggested that this could be true for an explosion in two rooms. In our studies we used a test unit with two connected chambers, each having a volume of 1.125 m3. It turned out that this influence of the adjacent volume was not so unambiguous as it was described in those publications. It was found out that the maximum effect of explosion pressure amplification by the adjacent room is achieved, when the igniter is located in the chamber filled with a gas-air mixture in the area between the center of the chamber and the window (maximum amplification by more than 3 times. This effect is lower directly by the window (1.8 times and is practically absent in case of ignition within the area near the passage connecting the chamber with the adjacent room. This suggests that the effect discovered earlier is a special case of the general dependence of the gas explosion pressure in two chambers on the igniter location.

  19. Isolation and Identification of Pathogenic Fungi from Air Conditioners in Tutorial Rooms of the Faculty of Medicine, Universitas Padjadjaran

    Directory of Open Access Journals (Sweden)

    Gowre Govindasamy

    2014-02-01

    Full Text Available Background: Awareness about health problems caused by air conditioner is very important. Thus, it is crucial to have knowledge about proper maintenance of air conditioner. At the Faculty of Medicine, Universitas Padjadjaran, air conditioners are used in every tutorial rooms. This study was performed to provide adequate information on the fungi, such as Aspergillus, Penicillium and Mucor, found in air conditioners. Methods: A descriptive laboratory study was used to identify the presence and the type of pathogenic fungi from air conditioners in tutorial rooms. Thirty-four samples were collected from the air outlet grille of the air conditioners and cultured on Sabouraud agar at 27°C for 2 weeks. Fungi presence were then identified microscopically Results: The results showed that the majority of air conditioners in tutorial rooms of the Faculty of Medicine, University Padjadjaran contained many types of fungus that grew in Sabouraud agar. From 34 samples, thirty two samples were positive and 2 samples were negative. Various fungus have been identified, those were Penicillium (37.5%, Aspergillus (25%, Mucor (2.5% and unidentified (35% Conclusions : The majority of air conditioners in tutorial rooms of the Faculty of Medicine, University Padjadjaran contained many types of opportunistic fungus. [AMJ.2014;1(1:21–4

  20. Comparison of waste anesthetic gases in operating rooms with or without an scavenging system in a Brazilian University Hospital

    Directory of Open Access Journals (Sweden)

    Leandro Gobbo Braz

    2017-09-01

    Full Text Available Background and objectives: Occupational exposure to waste anesthetic gases in operating room without active scavenging system has been associated with adverse health effects. Thus, this study aimed to compare the trace concentrations of the inhalational anesthetics isoflurane and sevoflurane in operating room with and without central scavenging system. Method: Waste concentrations of isoflurane and sevoflurane were measured by infrared analyzer at different locations (near the respiratory area of the assistant nurse and anesthesiologist and near the anesthesia station and at two times (30 and 120 min after the start of surgery in both operating room types. Results: All isoflurane and sevoflurane concentrations in unscavenged operating room were higher than the US recommended limit (2 parts per million, regardless of the location and time evaluated. In scavenged operating room, the average concentrations of isoflurane were within the limit of exposure, except for the measurements near the anesthesia station, regardless of the measurement times. For sevoflurane, concentrations exceeded the limit value at all measurement locations and at both times. Conclusions: The exposure to both anesthetics exceeded the international limit in unscavenged operating room. In scavenged operating room, the concentrations of sevoflurane, and to a lesser extent those of isoflurane, exceeded the recommended limit value. Thus, the operating room scavenging system analyzed in the present study decreased the anesthetic concentrations, although not to the internationally recommended values. Resumo: Justificativa e objetivos: A exposição ocupacional aos resíduos de gases anestésicos em salas de operação (SO sem sistema ativo de exaustão tem sido associada a efeitos adversos à saúde. Assim, o objetivo do estudo foi comparar os resíduos dos anestésicos inalatórios isoflurano e sevoflurano em SO com e sem sistema de exaustão. Método: Concentrações residuais

  1. Evaluating the auralization of a small room in a virtual sound environment using objective room acoustic measures

    DEFF Research Database (Denmark)

    Ahrens, Axel; Marschall, Marton; Dau, Torsten

    2016-01-01

    To study human auditory perception in realistic environments, loudspeaker-based reproduction techniques have recently become state-of-the-art. To evaluate the accuracy of a simulation-based room auralization of a small room, objective measures, such as early-decay-time (EDT), reverberation time...... of the room. The auralizations were generated using the loudspeaker-based room auralization toolbox (LoRA; Favrot and Buchholz, 2010) and reproduced in a 64-channel loudspeaker array, set up in an anechoic chamber. Differences between the objective measures evaluated in the real and the virtual room were......, clarity, interaural cross-correlation (IACC), and the speech transmission index were measured in an IEC listening room for 28 source-receiver combinations. The room was then modeled in the room acoustics software ODEON, and the same objective measures were also evaluated for the auralized version...

  2. Safety measures in exposure room

    International Nuclear Information System (INIS)

    Muhammad Jamal Md Isa

    2004-01-01

    The contents of this chapter are follows - The exposure room: location and dimension, material and thickness, windows, doors and other openings; Position of the Irradiating Apparatus, Use of Space Adjoining the Room, Warning Signs/Light, Dark Room. Materials and Apparatus: Classification of Areas, Local Rules, Other General Safety Requirements

  3. Extrato de alho como alternativa na quebra de dormência de gemas em macieiras cv. Fuji Kiku Garlic extract as alternative on bud dormant break of apple trees cv. Fuji Kiku

    Directory of Open Access Journals (Sweden)

    Renato Vasconcelos Botelho

    2007-04-01

    Full Text Available Este trabalho teve por objetivo estudar os efeitos do extrato de alho (Bioalho® na quebra de dormência de gemas de macieiras 'Fuji Kiku', em comparação ao uso convencional de cianamida hidrogenada (H2CN2, na região de Guarapuava-PR. Logo após a poda de inverno, em setembro de 2005, os seguintes tratamentos foram pulverizados nas plantas durante o estádio fenológico de gema dormente: 1 Testemunha (sem tratamento; 2 EA (extrato de alho 1%; 3 EA 5%; 4 EA 10%; 5 OM (óleo mineral 2%; 6 EA 1% + OM 2%; 7 EA 5% + OM 2%; 8 EA 10% + OM 2%; 9 H2CN2 0,4% + OM 4%. Os tratamentos com extrato de alho e óleo mineral apresentaram efeitos similares ao tratamento convencional com cianamida hidrogenada e óleo mineral, atingindo mais de 90% de brotação das gemas aos 50 DAT, enquanto o tratamento com óleo mineral isoladamente a 2% e a testemunha atingiram apenas 62,5 e 42,7%, respectivamente. Os tratamentos com EA 5% ou 10%, com ou sem óleo mineral, foram os que apresentaram menores valores para as variáveis número de frutos, produção por planta e produtividade por área, não por ineficiência na quebra de dormência, mas, possivelmente, pela antecipação da floração que coincidiu com período bastante chuvoso no início da primavera.This study aimed to examine the effects of garlic extract (Bioalho® on bud break of 'Fuji Kiku' apple trees in comparison to the conventional use of hydrogen cyanamide (H2CN2 at the region of Guarapuava-PR, Brazil. Soon after winter pruning, in September 2005, the following treatments were sprayed on plants at dormant bud stage: 1 control (untreated; 2 1% GE (garlic extract; 3 5% GE; 4 10% GE; 5 2% MO (mineral oil; 6 1% GE + 2% MO; 7 5% GE + 2% MO; 8 10% GE + 2% MO; 9 0.4% H2CN2 + 4% MO. The treatments with garlic extract and mineral oil showed similar effects in comparison to the hydrogen cyanamide treatment, achieving up to 90% of bud sprouting at 50 DAT, while only 2% mineral oil and control, attained only 62

  4. Fire protection for clean rooms

    International Nuclear Information System (INIS)

    Kirson, D.

    1990-01-01

    The fire protection engineer often must decide what size fire can be tolerated before automatic fire suppression systems actuate. Is it a wastepaper basket fire, a bushel basket fire...? In the case of state-of-the-art clean rooms, the answer clearly is not even an incipient fire. Minor fires in clean rooms can cause major losses. This paper discusses what a clean room is and gives a brief overview of the unique fire protection challenges encountered. The two major causes of fire related to clean rooms in the semiconductor industry are flammable/pyrophoric gas fires in plastic ducts and polypropylene wet bench fires. This paper concentrates on plastic ductwork in clean rooms, sprinkler protection in ductwork, and protection for wet benches

  5. Room for caring

    DEFF Research Database (Denmark)

    Timmermann, Connie; Uhrenfeldt, Lisbeth; Birkelund, Regner

    2015-01-01

    Aim This study explores how seriously ill hospitalized patients' experience and assign meaning to their patient room. Background Modern hospitals and the rational underlying care and treatment of today have their emphasis on diagnosis, cure and treatment. Consequently, aesthetics in the patient...... rooms such as a view of nature or natural light entering the room are often neglected in caring for these patients. Method A phenomenological-hermeneutic study design was applied and data was collected through multiple qualitative interviews combined with observations at a teaching hospital in Denmark......-being, relief and hope for the patients during serious illness. Therefore, these sensory impressions should be thought of as holding palliative potential and should be included as a part of caring for the seriously ill patients....

  6. Control room design

    International Nuclear Information System (INIS)

    Zinke, H.

    1980-01-01

    To control a 1300 megawatt nuclear power plant, about 15000 plant parameters must be collected together to control and operate the plant. The control room design therefore is of particular importance. The main design criteria are: Required functions of the power plant process - Level of Automation - Ergonomics - Available Technology. Extensive analysis has resulted in a control room design method. This ensures that an objective solution will be reached. Resulting from this methodical approach are: 1. Scope, position and appearance of the instrumentation. 2. Scope, position and appearance of the operator controls. Process analysis dictates what instrumentation and operator controls are needed. The priority and importance of the control and instrumentation (this we define as the utilisation areas), dictates the rough layout of the control room. (orig./RW)

  7. User Requirements Model for University Timetable Management System

    OpenAIRE

    Ahmad Althunibat; Mohammad I. Muhairat

    2016-01-01

    Automated timetables are used to schedule courses, lectures and rooms in universities by considering some constraints. Inconvenient and ineffective timetables often waste time and money. Therefore, it is important to investigate the requirements and potential needs of users. Thus, eliciting user requirements of University Timetable Management System (TMS) and their implication becomes an important process for the implementation of TMS. On this note, this paper seeks to propose a m...

  8. First installation of a dual-room IVR-CT system in the emergency room.

    Science.gov (United States)

    Wada, Daiki; Nakamori, Yasushi; Kanayama, Shuji; Maruyama, Shuhei; Kawada, Masahiro; Iwamura, Hiromu; Hayakawa, Koichi; Saito, Fukuki; Kuwagata, Yasuyuki

    2018-03-05

    Computed tomography (CT) embedded in the emergency room has gained importance in the early diagnostic phase of trauma care. In 2011, we implemented a new trauma workflow concept with a sliding CT scanner system with interventional radiology features (IVR-CT) that allows CT examination and emergency therapeutic intervention without relocating the patient, which we call the Hybrid emergency room (Hybrid ER). In the Hybrid ER, all life-saving procedures, CT examination, damage control surgery, and transcatheter arterial embolisation can be performed on the same table. Although the trauma workflow realized in the Hybrid ER may improve mortality in severe trauma, the Hybrid ER can potentially affect the efficacy of other in/outpatient diagnostic workflow because one room is occupied by one severely injured patient undergoing both emergency trauma care and CT scanning for long periods. In July 2017, we implemented a new trauma workflow concept with a dual-room sliding CT scanner system with interventional radiology features (dual-room IVR-CT) to increase patient throughput. When we perform emergency surgery or interventional radiology for a severely injured or ill patient in the Hybrid ER, the sliding CT scanner moves to the adjacent CT suite, and we can perform CT scanning of another in/outpatient. We believe that dual-room IVR-CT can contribute to the improvement of both the survival of severely injured or ill patients and patient throughput.

  9. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft; Gao, Yi; Petersson, Eva

    2015-01-01

    This paper presents the design and evaluation of a usability and user experience test of a virtual dressing room. First, we motivate and introduce our recent developed prototype of a virtual dressing room. Next, we present the research and test design grounded in related usability and user...... experience studies. We give a description of the experimental setup and the execution of the designed usability and user experience test. To this end, we report interesting results and discuss the results with respect to user-centered design and development of a virtual dressing room....

  10. Peer communication on sex and sexual health among youths: a case of Debre Berhan university, Ethiopia.

    Science.gov (United States)

    Gezahegn, Takele; Birhanu, Zewdie; Aman, Mamusha; Dessalegn, Muluken; Abera, Asmamaw; Nyagero, Josephat

    2016-01-01

    Friends are considered an important source of advice and information about sex. Conversations about sex among young people tend to generate norms that influence positive or negative pressure on individuals to conform to group standards. The aim of the study was to explore peer communication on sex and sexual health. Grounded theory qualitative study design was employed using focus group discussions and participant observation. Participants were selected using criterion purposive sampling. Semi-structured guides and checklists were used as data collection tools. Information was audio-recorded and transcribed verbatim and uploaded to ATLAS.ti 7 software for coding. Data collection and analysis were undertaken simultaneously using constant comparative analysis. Students talked with peers and sexual partners about sex more than sexual health issues. Common places of talk included dormitory, begtera (near dorm where students meet), and space (reading rooms). Whereas, time of talk, either in a group or with just their close friends or sex partners, included during training, evening and weekend time, during walking together, and break time. Students used verbal and non-verbal and formal and informal communication styles. The content, place, and time for discussions about sex were influenced by gender, social-cultural norms (e.g. religion), rural vs urban living, and the occurrence of sexual health issues (e.g, sexually-transmitted infections or unwanted pregnancies). Priority should be given to designing audience-specific strategies and messages to promote discussions about sex and to encourage safe sexual practices. Primary target groups should include female and rural students, who are predisposed to risky sexual behavior.

  11. Two phase heuristic algorithm for the university course timetabling

    African Journals Online (AJOL)

    Mgina

    Department of Mathematics, Box 35062, University of Dar es salaam, Tanzania ... and rooms to a number of timeslots over a planning horizon, normally a week, while ... Solutions have been generated which greatly outperform the manually ...

  12. Control room habitability during severe accidents

    International Nuclear Information System (INIS)

    Siu, R.P.

    1989-01-01

    The requirements for protection of control room personnel against radiation hazards are specified in 10CFR50, Appendix A, GDC 19. The conventional approach involves a mechanistic evaluation of the radiation doses to control room personnel during design-basis accidents. In this study, an assessment of control room habitability during severe accidents is conducted. The potential levels of radiation hazards to control room personnel are evaluated in terms of both magnitude and probability of occurrence. The expected values for the probabilities of exceeding GDC-19 limits and the cumulative probability distributions of control room doses are determined. In this study, a pressurized water reactor with a large dry containment has been selected for analysis. The types of control rooms evaluated in this study include designs with: (a) filtered local intakes only, (b) filtered recirculation only, (c) filtered local intakes and recirculation, and (d) filtered dual remote intakes and recirculation. From the observations, it is concluded that, except for control room D, all other control room designs may require improvements in order to provide adequate radiation protection during severe accidents, particularly in terms of reducing whole-body gamma doses and skin doses. Potential design improvements include reduction of intake flows for concepts relying on pressurization, reduction in overall leakages, and control room pressurization through the use of bottled air supply

  13. Films and dark room

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After we know where the radiographic come from, then we must know about the film and also dark room. So, this chapter 5 discusses the two main components for radiography work that is film and dark room, places to process the film. Film are structured with three structured that are basic structured, emulsion and protection structured. So, this film can be classified either with their speed, screen and standard that used. The process to wash the film must be done in dark room otherwise the radiographer cannot get what are they inspected. The processing of film will be discussed briefly in next chapter.

  14. The conference hybrid control room

    International Nuclear Information System (INIS)

    Gieci, A.; Caucik, J.; Macko, J.

    2008-01-01

    An original concept of a hybrid control room was developed for the Mochovce-3 and Mochovce-4 reactor units which are under construction. The basic idea underlying the concept is that the control room should be a main working place for the operators (reactor operator and turbine operator) and for the shift supervisor, designed as a comprehensive unit desk shaped so that all members of the control room crew are in a face-to-face contact constantly. The main desk consists of three clearly identified areas serving the operators and the unit supervisor as their main working places. A soft control system is installed at the main working places. A separate safety-related working place, designed as a panel with classical instrumentations at the conference hybrid control room, is provided in case of abnormal conditions or emergency situation. Principles of ergonomics and cognitive engineering were taken into account when designing the new conference hybrid control room for the Mochovce-3 and -4 reactor units. The sizes, propositions, shapes and disposition of the equipment at the control room have been created and verified by using virtual reality tools. (orig.)

  15. Modern control room for AHWR

    International Nuclear Information System (INIS)

    Verghese, Clement C.; Joseph, Jose; Biswas, B.B.; Patil, R.K.

    2005-01-01

    Advanced Heavy Water Reactor (AHWR) is a next generation nuclear power plant being developed by Bhabha Atomic Research Centre. A modern control room has been conceived for operation and monitoring of the plant in tune with the advanced features of the reactor. A state of the art C and I architecture based on extensive use of computers and networking has been conceived for this plant. This architecture enables the implementation of a fully computerised operator friendly control room with soft HMIs. Features of the modern control room and control room and concept of soft HMI based operator interfaces have been described in the paper. (author)

  16. Leadership in the control room

    International Nuclear Information System (INIS)

    McDougall, S.J.

    2006-01-01

    This paper discusses the importance of leadership within the control rooms at nuclear power facilities. the leadership capability of control room staff has a significant influence over the improvement of human performance and the development of an 'event free' culture within the business. The development of leadership competency in the control room must be an important part of any nuclear power utility business improvement plan. (author)

  17. Métodos para quebra de dormência de unidades de dispersão de Zizyphus joazeiro Mart. (Rhamnaceae Methods for dormancy breaking of Zizyphus joazeiro Mart. dispersal units

    Directory of Open Access Journals (Sweden)

    Edna Ursulino Alves

    2008-06-01

    Full Text Available O Z. joazeiro é uma espécie florestal de grande importância socioeconômica para a Região Nordeste do Brasil e apresenta dificuldades na germinação das unidades de dispersão, causada pela impermeabilidade à água. Este estudo avaliou tratamentos pré-germinativos de superação de dormência de unidades de dispersão de Z. joazeiro. O experimento foi conduzido em casa de vegetação, no Centro de Ciências Agrárias da Universidade Federal da Paraíba, em Areia, PB, Brasil. Os tratamentos consistiram em: testemunha (unidades de dispersão intactas, escarificação mecânica com lixa d'água, imersão em água, à temperatura ambiente, por 24, 48, 72, 96 e 120 h, imersão em água à temperatura de 70 ºC, por 3 min, e imersão em ácido sulfúrico concentrado por 30, 60, 90, 120 e 150 min. As variáveis avaliadas foram porcentagem de emergência, primeira contagem e velocidade de emergência, comprimento e massa seca de plantas. Os tratamentos que propiciaram máxima emergência de plântulas de Z. joazeiro foram imersão de unidades de dispersão em água fria por 48 h, imersão em água a 70 ºC por 3 min e escarificação manual com lixa, por superar a dureza tegumentar das unidades de dispersão dessa espécie.Z. joazeiro is a forest species of great socioeconomic importance for the Brazilian Northeast region, but of difficult germination caused by the water impermeability of dispersal units. The present study evaluated pre-germinative treatments for overcoming dormancy in Zizyphus joazeiro seeds. The experiment was carried out in greenhouse conditions at Centro de Ciencias Agrárias, Universidade Federal da Paraíba, Areia-PB, Brazil. The treatments were as follow: control (intact dispersal units, mechanical scarification with sandpaper, immersion in water at room temperature for 24, 48, 72, 96 and 120 hours, immersion in water at 70 C for three minutes and, immersion in concentrated sulfuric acid for 30, 60, 90, 120 and 150 minutes

  18. Operating room manager game

    NARCIS (Netherlands)

    Hans, Elias W.; Nieberg, T.

    2007-01-01

    The operating room (OR) department of a hospital forms the heart of the organization, where the single largest cost is incurred. This document presents and reports on the “Operating Room Manager Game,” developed to give insight into managing a large hospital's OR department at various levels of

  19. Leadership in the control room

    Energy Technology Data Exchange (ETDEWEB)

    McDougall, S.J. [Bruce Power, Bruce B Operations Div., Tiverton, Ontario (Canada)

    2006-07-01

    This paper discusses the importance of leadership within the control rooms at nuclear power facilities. the leadership capability of control room staff has a significant influence over the improvement of human performance and the development of an 'event free' culture within the business. The development of leadership competency in the control room must be an important part of any nuclear power utility business improvement plan. (author)

  20. A comparison of two instructional methods for drawing Lewis Structures

    Science.gov (United States)

    Terhune, Kari

    Two instructional methods for teaching Lewis structures were compared -- the Direct Octet Rule Method (DORM) and the Commonly Accepted Method (CAM). The DORM gives the number of bonds and the number of nonbonding electrons immediately, while the CAM involves moving electron pairs from nonbonding to bonding electrons, if necessary. The research question was as follows: Will high school chemistry students draw more accurate Lewis structures using the DORM or the CAM? Students in Regular Chemistry 1 (N = 23), Honors Chemistry 1 (N = 51) and Chemistry 2 (N = 15) at an urban high school were the study participants. An identical pretest and posttest was given before and after instruction. Students were given instruction with either the DORM (N = 45), the treatment method, or the CAM (N = 44), the control for two days. After the posttest, 15 students were interviewed, using a semistructured interview process. The pretest/posttest consisted of 23 numerical response questions and 2 to 6 free response questions that were graded using a rubric. A two-way ANOVA showed a significant interaction effect between the groups and the methods, F (1, 70) = 10.960, p = 0.001. Post hoc comparisons using the Bonferroni pairwise comparison showed that Reg Chem 1 students demonstrated larger gain scores when they had been taught the CAM (Mean difference = 3.275, SE = 1.324, p Chemistry 1 students performed better with the DORM, perhaps due to better math skills, enhanced working memory, and better metacognitive skills. Regular Chemistry 1 students performed better with the CAM, perhaps because it is more visual. Teachers may want to use the CAM or a direct-pairing method to introduce the topic and use the DORM in advanced classes when a correct structure is needed quickly.

  1. Requirements for Control Room Computer-Based Procedures for use in Hybrid Control Rooms

    Energy Technology Data Exchange (ETDEWEB)

    Le Blanc, Katya Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States); Oxstrand, Johanna Helene [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey Clark [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    Many plants in the U.S. are currently undergoing control room modernization. The main drivers for modernization are the aging and obsolescence of existing equipment, which typically results in a like-for-like replacement of analogue equipment with digital systems. However, the modernization efforts present an opportunity to employ advanced technology that would not only extend the life, but enhance the efficiency and cost competitiveness of nuclear power. Computer-based procedures (CBPs) are one example of near-term advanced technology that may provide enhanced efficiencies above and beyond like for like replacements of analog systems. Researchers in the LWRS program are investigating the benefits of advanced technologies such as CBPs, with the goal of assisting utilities in decision making during modernization projects. This report will describe the existing research on CBPs, discuss the unique issues related to using CBPs in hybrid control rooms (i.e., partially modernized analog control rooms), and define the requirements of CBPs for hybrid control rooms.

  2. Noise disturbance in open-plan study environments: a field study on noise sources, student tasks and room acoustic parameters.

    Science.gov (United States)

    Braat-Eggen, P Ella; van Heijst, Anne; Hornikx, Maarten; Kohlrausch, Armin

    2017-09-01

    The aim of this study is to gain more insight in the assessment of noise in open-plan study environments and to reveal correlations between noise disturbance experienced by students and the noise sources they perceive, the tasks they perform and the acoustic parameters of the open-plan study environment they work in. Data were collected in five open-plan study environments at universities in the Netherlands. A questionnaire was used to investigate student tasks, perceived sound sources and their perceived disturbance, and sound measurements were performed to determine the room acoustic parameters. This study shows that 38% of the surveyed students are disturbed by background noise in an open-plan study environment. Students are mostly disturbed by speech when performing complex cognitive tasks like studying for an exam, reading and writing. Significant but weak correlations were found between the room acoustic parameters and noise disturbance of students. Practitioner Summary: A field study was conducted to gain more insight in the assessment of noise in open-plan study environments at universities in the Netherlands. More than one third of the students was disturbed by noise. An interaction effect was found for task type, source type and room acoustic parameters.

  3. The Influence of Information Technology on Student's Behavioural Nature in the Class Room

    Science.gov (United States)

    Ali, Liaqat

    2018-01-01

    The use of mobile phones and other gadgets in the university class room is becoming a culture in the modern age of technology. Some students use this technology for the purpose of information only. However, it was noted that others use mobile phone to receive messages through different applications such as WhatsApp, Facebook, Instagram and Viber.…

  4. Operating room fires in periocular surgery.

    Science.gov (United States)

    Connor, Michael A; Menke, Anne M; Vrcek, Ivan; Shore, John W

    2018-06-01

    A survey of ophthalmic plastic and reconstructive surgeons as well as seven-year data regarding claims made to the Ophthalmic Mutual Insurance Company (OMIC) is used to discuss operating room fires in periocular surgery. A retrospective review of all closed claim operating room fires submitted to OMIC was performed. A survey soliciting personal experiences with operating room fires was distributed to all American Society of Oculoplastic and Reconstructive Surgeons. Over the last 2 decades, OMIC managed 7 lawsuits resulting from an operating room fire during periocular surgery. The mean settlement per lawsuit was $145,285 (range $10,000-474,994). All six patients suffered burns to the face, and three required admission to a burn unit. One hundred and sixty-eight surgeons participated in the online survey. Approximately 44% of survey respondents have experienced at least one operating room fire. Supplemental oxygen was administered in 88% of these cases. Most surgical fires reported occurred in a hospital-based operating room (59%) under monitored anesthesia care (79%). Monopolar cautery (41%) and thermal, high-temperature cautery (41%) were most commonly reported as the inciting agents. Almost half of the patients involved in a surgical fire experienced a complication from the fire (48%). Sixty-nine percent of hospital operating rooms and 66% of ambulatory surgery centers maintain an operating room fire prevention policy. An intraoperative fire can be costly for both the patient and the surgeon. Ophthalmic surgeons operate in an oxygen rich and therefore flammable environment. Proactive measures can be undertaken to reduce the incidence of surgical fires periocular surgery; however, a fire can occur at any time and the entire operating room team must be constantly vigilant to prevent and manage operating room fires.

  5. 32 CFR 518.9 - Reading room.

    Science.gov (United States)

    2010-07-01

    ... RELATIONS THE FREEDOM OF INFORMATION ACT PROGRAM FOIA Reading Rooms § 518.9 Reading room. (a) Reading room... clearly unwarranted invasions of privacy, or competitive harm to business submitters. In appropriate cases... information concerning munitions, equipment, systems, and intelligence activities. (4) (a)(2)(D) records...

  6. 7 CFR 58.312 - Churn rooms.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Churn rooms. 58.312 Section 58.312 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....312 Churn rooms. Churn rooms in addition to proper construction and sanitation shall be so equipped...

  7. University course timetabling and the requirements: Survey in several universities in the east-coast of Malaysia

    Science.gov (United States)

    Aziz, Nurul Liyana Abdul; Aizam, Nur Aidya Hanum

    2017-08-01

    Course timetabling problem receives the highlight at the beginning of every semester. The problem is mainly on assigning courses to timeslot, rooms and lecturers which involving a set of rules and policies constraints. Generally, researchers present different features to signify their own universities' timetable according to the structure and behavior of their institution. However, the gap between theory and real-world applications that can be seen in the resulted timetable is the lacking of acknowledging human preferences. As to overcome this, it is very important to consider all the demands and preferences from timetabling community. This research therefore tries to accommodate the problem by investigating through surveys to several universities in the east coast of Malaysia the demands and preferences of individuals involved directly. Results from the questionnaires will be analyzed by using SPSS and all current issues regarding the demands will be included into our existing general university course timetabling mathematical model. The new university course timetabling mathematical model could best represent universities and be useful, especially in universities in Malaysia.

  8. Manufacturing of NAA laboratory clean room

    International Nuclear Information System (INIS)

    Suwoto; Hasibuan, Djaruddin

    2001-01-01

    The ''NAA laboratory clean room'' has been built in the Reactor Serba Guna G.A. Siwabessy building. The erection of ''AAN laboratory clean room'' doing by started of preparation of the ''manufacturing procedure'' refer to ''Design and manufacturing neutron activation analysis clean room laboratory''. Manufacturing process and erection doing refer to procedures makes. By providing of the ''AAN laboratory clean room'' can be cocluded that the research activity and the user sevises in P2TRR well meet to be done

  9. Auditory modelling for assessing room acoustics

    NARCIS (Netherlands)

    Van Dorp Schuitman, J.

    2011-01-01

    The acoustics of a concert hall, or any other room, are generally assessed by measuring room impulse responses for one or multiple source and receiver location(s). From these responses, objective parameters can be determined that should be related to various perceptual attributes of room acoustics.

  10. Ácido sulfúrico superação da dormência de unidade de dispersão de juazeiro (Zizyphus joazeiro Mart. The use of sulfuric acid to break dispersal unit dormancy of Zizyphus joazeiro Mart.

    Directory of Open Access Journals (Sweden)

    Edna Ursulino Alves

    2006-04-01

    Full Text Available O Zizyphus joazeiro Mart. apresenta redução sensível no número de indivíduos em seu ambiente natural devido, entre outras causas, à ocorrência de dormência exógena da unidade de dispersão (impermeabilidade à água. Avaliou-se o efeito do período de imersão (0, 30, 60, 90, 120 e 150 min dessas unidades de dispersão, em ácido sulfúrico (98 %, na emergência e vigor das sementes (primeira contagem, índice de velocidade e tempo médio de emergência, altura e massa seca de plantas. O experimento foi realizado em casa de vegetação, utilizando-se o delineamento inteiramente ao acaso, com seis tratamentos e quatro repetições. O pré-condicionamento das unidades de dispersão de Zizyphus joazeiro Mart., em ácido sulfúrico concentrado, mostrou-se eficiente na superação da dormência dessa espécie, promovendo aumento na porcentagem e velocidade de emergência, primeira contagem de emergência, na altura e massa seca de plantas e redução no tempo médio para emergência. A eficiência do tratamento químico com ácido sulfúrico concentrado depende do período de imersão, sendo a faixa entre 74 e 115 min mais adequada para proporcionar maiores porcentagens de emergência e de vigor.Zizyphus joazeiro Mart. trees have been declining in number in their natural habitat due to, among other reasons, the occurrence of dormancy of dispersal units (water impermeability. The effect of the immersion time (0, 30, 60, 90, 120 and 150 minutes of Zizyphus joazeiro Mart. dispersal units in concentrated sulfuric acid (95-98 % was evaluated through the emergency and vigor (first count, speed index and mean emergence time, plant height and dry matter weight. The experiment was performed under greenhouse conditions, with a completely randomized experimental design, six treatments and four replications. The pre-conditioning of Zizyphus joazeiro Mart. dispersal units with immersion in concentrated sulfuric acid was efficient for breaking the seed

  11. Transformation of a Pediatric Primary Care Waiting Room: Creating a Bridge to Community Resources.

    Science.gov (United States)

    Henize, Adrienne W; Beck, Andrew F; Klein, Melissa D; Morehous, John; Kahn, Robert S

    2018-06-01

    Introduction Children and families living in poverty frequently encounter social risks that significantly affect their health and well-being. Physicians' near universal access to at-risk children and their parents presents opportunities to address social risks, but time constraints frequently interfere. We sought to redesign our waiting room to create a clinic-to-community bridge and evaluate the impact of that redesign on family-centered outcomes. Methods We conducted a pre-post study of a waiting room redesign at a large, academic pediatric primary care center. Design experts sought input about an optimal waiting room from families, community partners and medical providers. Family caregivers were surveyed before and after redesign regarding perceived availability of help with social needs and access to community resources, and hospitality and feelings of stress. Pre-post differences were assessed using the Chi square or Wilcoxon rank sum test. Results The key redesign concepts that emerged included linkages to community organizations, a welcoming environment, and positive distractions for children. A total of 313 caregiver surveys were completed (pre-160; post-153). Compared to pre-redesign, caregivers surveyed post-redesign were significantly more likely to perceive the waiting room as a place to obtain help connecting to community resources and find information about clinical and educational resources (both p < 0.05). Families were also significantly more likely to report the waiting room as more welcoming and relaxing, with sufficient privacy and space (all p < 0.05). Discussion Waiting rooms, typically a place of wasted time and space, can be redesigned to enhance families' engagement and connection to community resources.

  12. A room of one's own--Being cared for in a hospital with a single-bed room design.

    Science.gov (United States)

    Persson, Eva; Anderberg, Patrice; Ekwall, Anna Kristensson

    2015-06-01

    To illuminate patients' experiences of being hospitalised in a hospital with a single-bed room design. Many patients seem to prefer single-bed hospital rooms. However, studies have also shown that patients do see the advantages of multiple-bed rooms. Interviews were conducted with 16 inpatients from a surgical ward in a hospital building with a single-bed room design. A hermeneutical-phenomenological approach guided by van Manen's four life-world existentials was used to analyse the interviews. The essential meaning was that patients felt secure because they could create a personal environment without disruptive elements. The room was private, and this implied feelings of homeliness, which allowed patients to focus on themselves and was thought to facilitate the recovery process. The patients preferred staying in their room, and the relationship with the personnel was central. Feelings of loneliness and isolation could occur and could be frightening. Being hospitalised in a single-bed room meant balancing between feeling secure and feeling insecure. The following four themes emerged: A homely environment, The need for company and security, Time as unpredictable and involving waiting and Focus on healing the body. Patients experienced that a single-bed room allowed them to focus on their recovery, have visitors without disturbing others and create a feeling of homeliness. However, mobilisation is not a natural part of the recovery process when patients have all they need in their rooms. The patients' need for social interaction and confirmation was not satisfied without effort and planning on the part of staff. © 2014 Nordic College of Caring Science.

  13. ALICE’s new meeting room

    CERN Multimedia

    2009-01-01

    There’s no reason to be late for a meeting in Wonderland (Point 2) anymore as ALICE gets a brand new conference room and a ‘clean up’. The new ALICE conference room.You won’t find Building 3294 on the CERN map yet, but it is already being used. If you follow the white rabbit just inside the entrance at point 2, you will find a new conference room and office space for 12 people. "Previously at Point 2 we’ve had very little office space at all. Our old conference room was inside the main building, SX2, but it was cramped and extremely noisy," explained Frank Cliff from ALICE. "As soon as they turned on the overhead cranes you could barely hear yourself think!" The plans for the new building were drawn up by the Civil Engineering Group, and construction started in August last year. The building was completed and already in use before Christmas. The 109 square metre conference room can fit up to 60 people and is fully equipped...

  14. An Optimisation Approach for Room Acoustics Design

    DEFF Research Database (Denmark)

    Holm-Jørgensen, Kristian; Kirkegaard, Poul Henning; Andersen, Lars

    2005-01-01

    This paper discuss on a conceptual level the value of optimisation techniques in architectural acoustics room design from a practical point of view. It is chosen to optimise one objective room acoustics design criterium estimated from the sound field inside the room. The sound field is modeled...... using the boundary element method where absorption is incorporated. An example is given where the geometry of a room is defined by four design modes. The room geometry is optimised to get a uniform sound pressure....

  15. A University forum on low-level waste

    International Nuclear Information System (INIS)

    Ring, J.; Lorenzen, W.; Osborne, F.; Shapiro, J.

    1995-01-01

    This article describes the Biomedical Radioactive Waste Management Program at Harvard University. Included is an overview of the program and specific discussions of education of laboratory technicians; specific waste processing methods; laboratory decay-in-storage; packaging by researcher; processing in the local waste room; transfer from local disposal to on-site management facility; program results

  16. Hybrid control rooms: the effects of introducing new technology into existing control rooms

    International Nuclear Information System (INIS)

    Morisseau, Dolores S.

    2001-02-01

    The goal of this part of the Hybrid Control Room Project is to gain a perspective on the issues and problems that are an integral part of introducing new technology, automated systems, or support systems into nuclear power plant (NPP) control rooms, particularly when they are introduced on a system-by-system basis. For purposes of this project, hybrid control rooms are defined as those into which new technology, such as digital and computer-based controls are gradually incorporated as opposed to those that are completely, or nearly completely, refitted with new technology. Although the focus of this project is the introduction of computer based, digital systems into NPP control rooms, it is not possible to exclude the effects throughout the process that are inevitable when new technology is introduced anywhere in complex process control systems. Thus, this document examines the effects of such changes within the context of the organisation in which they occur, including the management of change, work procedures and work methods, communications and crew interaction, training, and the interdependent functions in the operational context. (Author)

  17. Birth room images

    DEFF Research Database (Denmark)

    Bowden, Calida; Sheehan, Athena; Foureur, Maralyn Jean

    2016-01-01

    Objective: this study examined images of birth rooms in developed countries to analyse the messages and visual discourse being communicated through images. Design: a small qualitative study using Kress and van Leeuwen's (2006) social semiotic theoretical framework for image analysis, a form...... and implications for practice: as images on the Internet inform and persuade society about stereotypical behaviours, the trends of our time and sociocultural norms, it is important to recognise images of the technological birth room on the Internet may be influential in dictating women's attitudes, choices...

  18. Creating Engaging Escape Rooms for the Classroom

    Science.gov (United States)

    Nicholson, Scott

    2018-01-01

    Escape rooms are "live-action team-based games where players discover clues, solve puzzles, and accomplish tasks in one or more rooms in order to accomplish a specific goal (usually escaping from the room) in a limited amount of time." Escape Rooms are one type of Escape Game, which are narrative-based challenges that use puzzles, tasks,…

  19. Hospital Patient Room Design: The Issues Facing 23 Occupational Groups Who Work in Medical/Surgical Patient Rooms.

    Science.gov (United States)

    Lavender, Steven A; Sommerich, Carolyn M; Patterson, Emily S; Sanders, Elizabeth B-N; Evans, Kevin D; Park, Sanghyun; Umar, Radin Zaid Radin; Li, Jing

    2015-01-01

    The aim of this study was to learn from a wide range of hospital staff members about how the design of the patient room in which they work adversely affects their ergonomics or hinders their job performance. In addition to providing a healing space for patients, hospital patient rooms need to serve as functional workplaces for the people who provide clinical care, to clean, or to maintain room functions. Therefore, from a design perspective, it is important to understand the needs of all the users of hospital patient rooms with regard to room design. One hundred forty-seven people, representing 23 different occupational stakeholder groups, participated in either focus groups or interviews in which they were asked to identify room design issues that affect the performance of their work tasks. Key issues shared across multiple stakeholder groups included an inability to have eye contact with the patient when entering the room, inadequate space around the bed for the equipment used by stakeholders, the physical demands experienced as stakeholders move furnishings to accomplish their activities or access equipment, and a lack of available horizontal surfaces. Unique issues were also identified for a number of stakeholder groups. There are a number of issues that should be addressed in the next generation of hospital patient rooms, or when refurbishing existing facilities, so that all occupational stakeholder groups can work effectively, efficiently, and without undue physical stress. © The Author(s) 2015.

  20. In the LEAR control room

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    View into the control room of the Low Energy Antiproton Ring (LEAR). Edgar Asseo (sitting) and Dieter Möhl and Georges Carron reflecting upon some beam dynamics (or hardware?) problem. Vassilis Agoritsas, in the background, leaning over a plan or a keyboard. LEAR in its early years (1982 to about 1990) was run from this local control room in building 363 close to the end of the PS South Hall, where the ring was installed. Later-on the operation was surveyed from the PS main control room.

  1. Test Room Stability Plan

    International Nuclear Information System (INIS)

    1993-01-01

    This plan documents the combination of designs, installations, programs, and activities that ensures that the underground excavations at the Waste Isolation Pilot Plant (WIPP), in which transuranic (TRU) waste may be emplaced during the Test Phase, will remain sufficiently stable and safe during that time. The current ground support systems installed at the WIPP are the result of over ten years of data collection from hundreds of geomechanical instruments and thousands of hours of direct observation of the changing conditions of the openings. In addition, some of the world's most respected experts on salt rock mechanics have provided input in the design process and concurrence on the suitability of the final design. The general mine rockbolt pattern and the ground support system for the test rooms are designed to specifically address the fracture and deformation geometries observed today at the WIPP. After an introductory chapter, this plan describes the general underground design, then proceeds to an account of general ground support performance, and finally focuses on the details of the special test room ground support systems. One such system already installed in Room 1, Panel 1, is described in comprehensive detail. Other test rooms in Panel 1, whether full-size or smaller, will be equipped with systems that ensure stability to the same or equivalent extent. They will benefit from the experience gained in the first test room, which in turn benefitted from the data and knowledge accumulated during previous stages (e.g., the Site and Preliminary Design Validation program) of the project

  2. Human-factors engineering control-room design review/audit report: Byron Generating Station, Commonwealth Edison Company

    International Nuclear Information System (INIS)

    Savage, J.W.

    1983-01-01

    A human factors engineering design review/audit of the Byron Unit 1 control room was performed at the site on November 17 through November 19, 1981. This review was accomplished using the Unit 2 control room appropriately mocked-up to reflect design changes already committed to be incorporated in Unit 1. The report was prepared on the basis of the HFEB's audit of the applicant's Preliminary Design Assessment report and the human factors engineering design review performed at the site. This design review was carried out by a team from the Human Factors Engineering Branch, Division of Human Factors Safety. The review team was assisted by consultants from BioTechnology, Inc. (Falls Church, Virginia), and from Lawrence Livermore National Laboratory (University of California), Livermore, California

  3. Penerapan Framework Yii dalam Pembangunan Sistem Informasi Asrama Santri Pondok Pesantren sebagai Media Pencarian Asrama Berbasis Web

    Directory of Open Access Journals (Sweden)

    Erliyah Nurul Jannah

    2015-10-01

    Full Text Available The need of information technology in the modern era is inevitable. It occurs in most of institutions, including the Islamic Boarding School. Parents of Islamic Boarding School students have difficulty in choosing a proper dorm for their child in new academic year. This happens because there are many choices provided by the boarding school. The dormitories vary in terms of cost, facilities, and activities of the dorm. Therefore, it is necessary to build a Dorm Information Systems (SIRAMA to assist parents and students in searching a dormitory that best meets their criteria. SIRAMA is a web-based application that serves as an information media about the dormitory at boarding school. The information consists of the initial cost of dormitory entrance, monthly fees, boarding facilities, and schedule activities of the dorm. SIRAMA is developed using waterfall model, implemented using PHP Yii framework as the programming language, and tested with black-box testing and user acceptance testing. The result shows that SIRAMA is capable to recommend a list of dormitories that meets the students or parents’ criteria. SIRAMA is also very well accepted by the users.

  4. Screening Criteria for a Room Cooling Failure of the AFW MDP Room

    International Nuclear Information System (INIS)

    Hwang, Mee Jeong; Yoon, Churl; Yang, Joon Eon; Park, Joo Hwan

    2006-01-01

    In this paper, we performed a heat up calculation for the Auxiliary Feedwater Motor Operated Pump (AFW MDP) room, PAB-077-11A with CFX-10 and RATT when the HVAC (Heating, Ventilation, and Air Condition) system is failed. We also reviewed the operability of the components under a loss of the HVAC. Room cooling failure does not need to be modeled if the components maintain their operability after a loss of a room cooling function during the mission time. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, 4 under the situation of a loss of the HVAC. However, if we consider the HVAC failure in the PSA FT model, the problem is that the unavailability induced from a loss of the HVAC is unrealistically high. From a viewpoint of the PSA, it is not true that the related system always fails even if the HVAC system fails. Therefore, we reviewed the necessity of the HVAC model through two cases of a room heat up calculation under the situation of a loss of the HVAC system with conservative and realistic input data respectively

  5. Evaluation of a dark-room

    International Nuclear Information System (INIS)

    Passos, J.C.

    1987-01-01

    The adequate operation conditions of a dark-room are essential to guarantee the image quality, the least exposure of the patient and the staff, contributing also to reduce the expenses with specific equipments and processing solutions. Therefore, to install a dark-room, it is necessary a previous study about its physical dimensions, the location of equipments, accessories, light safeguards and visual warning, besides adequate darkening and correct filme processing. We propose three basic tests to check the adequacy and the integrity of a dark-room: light safeguards test, hygiene test, developing time and temperature test. (Author) [pt

  6. Recovery Room

    African Journals Online (AJOL)

    defined postoperative unit or on the hospital ward. Patients were frequently transferred from the operating room directly to the ward where they were placed close to the nursing station. In 1947 the. Anesthesia Study Commission of the Philadelphia.

  7. Future control room design (modernization of control room systems); Zukuenftiges Wartendesign (Modernisierung von Warteneinrichtungen)

    Energy Technology Data Exchange (ETDEWEB)

    Reischl, Ludwig; Freitag, Timo; Dergel, Rene [AREVA NP (Germany). NLLR-G ' ' Reactor I and C' '

    2009-07-01

    In the frame of lifetime extension for nuclear power plants the modernization of the complete safety and operational control technology will be digitalized. It is also recommended to modernize the operator facilities, monitoring systems in the control room, the back-up shut-down center and the local control stations. The authors summarize the reasons for the modernization recommendations and discuss possible solutions for display-oriented control rooms. A concept for control room backfitting includes generic requirements, requirements of the local authorities, ergonomic principles information content and information density, and the design process. The backfitting strategy should include a cooperation with the operational personnel, The quality assurance and training via simulator needs sufficient timing during the implementation of the backfitting.

  8. Ergonomics influence on control room layout

    International Nuclear Information System (INIS)

    Hartfiel, H.D.

    1984-01-01

    Nowadays, human factors has become an important aspect of the design of work places. Since the control room in a nuclear power plant is a work place, too, its layout is also influenced by ergonomics. With the KWU control room concept for the 1300 MW PWR as an example, we show how assured and applicable ergonomic findings enter into the control room design. On the basis of general design principles for work places, specific methods for control room planning have been developed. By working with these methods a concept that makes it possible to build a man-machine interface able to fulfill the process control tasks with all their underlying conditions has been derived. (author)

  9. Nuclear power station main control room habitability

    International Nuclear Information System (INIS)

    Paschal, W.B.; Knous, W.S.

    1989-01-01

    The main control room at a nuclear power station must remain habitable during a variety of plant conditions and postulated events. The control room habitability requirement and the function of the heating, ventilating, air-conditioning, and air treatment system are to control environmental factors, such as temperature, pressure, humidity, radiation, and toxic gas. Habitability requirements provide for the safety of personnel and enable operation of equipment required to function in the main control room. Habitability as an issue has been gaining prominence with the Advisor Committee of Reactor Safeguards and the Nuclear Regulatory Commission since the incident at Three Mile Island. Their concern is the ability of the presently installed habitability systems to control the main control room environment after an accident. This paper discusses main control room HVAC systems; the concern, requirements, and results of NRC surveys and notices; and an approach to control room habitability reviews

  10. A remote control room at DIII-D

    International Nuclear Information System (INIS)

    Abla, G.; Schissel, D.P.; Penaflor, B.G.; Wallace, G.

    2008-01-01

    This paper describes a remote control room built at DIII-D to support remote participation activities of DIII-D research staff. In order to create a persistent, efficient, and reliable remote participation environment for DIII-D scientists, a remote control room has been built in a 640-ft 2 dedicated area. The purpose of this room is to experiment and define a remote control room framework that can facilitate the remote participation needs of current and future fusion experiments such as ITER. A variety of hardware equipment has been installed and several remote participation and collaboration technologies have been deployed. Objectivity and practical consideration has been the key while designing the room and deploying the technologies. Although, the DIII-D remote control room is still a work in progress and new software tools are being implemented, it has been already useful for a number of international remote participation activities. For example, it has been used for remote support of the EAST Tokamak in China during the start up operation and proven effective for other collaborative experiment activities. The description of the remote control room design is given along with technologies deployed for remote collaboration needs. We will also discuss our recent experiences involving the DIII-D remote control room as well as future plans for improvements

  11. Stability of disposal rooms during waste retrieval

    International Nuclear Information System (INIS)

    Brandshaug, T.

    1989-03-01

    This report presents the results of a numerical analysis to determine the stability of waste disposal rooms for vertical and horizontal emplacement during the period of waste retrieval. It is assumed that waste retrieval starts 50 years after the initial emplacement of the waste, and that access to and retrieval of the waste containers take place through the disposal rooms. It is further assumed that the disposal rooms are not back-filled. Convective cooling of the disposal rooms in preparation for waste retrieval is included in the analysis. Conditions and parameters used were taken from the Nevada Nuclear Waste Storage Investigation (NNWSI) Project Site Characterization Plan Conceptual Design Report (MacDougall et al., 1987). Thermal results are presented which illustrate the heat transfer response of the rock adjacent to the disposal rooms. Mechanical results are presented which illustrate the predicted distribution of stress, joint slip, and room deformations for the period of time investigated. Under the assumption that the host rock can be classified as ''fair to good'' using the Geomechanics Classification System (Bieniawski, 1974), only light ground support would appear to be necessary for the disposal rooms to remain stable. 23 refs., 28 figs., 2 tabs

  12. Cardiac arrest during anesthesia at a University Hospital in Nigeria ...

    African Journals Online (AJOL)

    Background: We assessed the incidence and outcomes of cardiac arrest during anesthesia in the operating room at our university hospital. A previous study on intraoperative cardiac arrests covered a period from 1994-1998 and since then; anesthetic personnel, equipment, and workload have increased remarkably.

  13. Consumer opinions of emergency room medical care.

    Science.gov (United States)

    McMillan, J R; Younger, M S; DeWine, L C

    1984-12-01

    If hospital management is to adapt successfully to an increasingly competitive environment, and to retain a viable emergency department, it well be necessary to objectively and accurately assess the hospital's image in the community served. Knowledge of the consumers' views is an essential input into the formulation of strategic plans. This article reports on a study in which consumer opinions on 15 dimensions of emergency room health care were obtained from 723 respondents using a mail questionnaire. Findings reveal that consumers view the emergency room as being more expensive than other health care providers. Except for being available or convenient, little or no advantage is perceived for the emergency room over the personal physician. Even though the emergency room has specialized staff and equipment, consumers do not believe patients receive better or faster treatment in an emergency room than would be obtained in a physician's office. Unless changed, these perceptions will diminish the role of the emergency room in the delivery of health care services.

  14. 46 CFR 111.105-41 - Battery rooms.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...

  15. Madness in Sartre's "The Room"

    NARCIS (Netherlands)

    Jongeneel, E.C.S.

    2009-01-01

    In "The Room," part of his short story collection, The Wall (1938), Jean-Paul Sartre investigates madness as an alternative way of bourgeois life and thus takes a stand in the contemporary debate on the existential status of mental illness. "The Room" is a case-study of a "limit situation," as well

  16. Evaluation of awareness concerning fire prevention and control methods among personnel of operating room in a hospital

    Directory of Open Access Journals (Sweden)

    2012-09-01

    Full Text Available Introduction: There are risk of fire accidents in Operating rooms during surgery. Experts estimate annually around 100 fire accidents occur in the operating rooms of United States’s hospitals. 10 to 20 of these accidents lead to severe injuries and about 1 to 2 lead to death. Despite such accidents rarely happen, but they can lead to serious injury or death of patients. .Material and Method: This Cross-sectional questionnaire based survey was conducted among several hospitals belonged to Shiraz University of Medical Sciences. In this study, all personnel of operating rooms were investigated. Questionnaire were used to collect information and the chi-square test was applied to examine the relationship between the Knowledge of operating room personels on fire prevention and control methods, jobs and work experience. For statistical analysis SPSS14 were used. .Result: In this study from 220 participants, about 19.72% had full awareness, 19.62% had partial knowledge, 19.37% had low awareness and 40.97% had no knowledge on fire prevention methods, concerning fire control methods. However, 76% of the participate had full awareness and 24% had no knowledge. Test result Statistically showed that the relationship between the awareness of operating room personnel to fire control methods and work experience were significant (P-value <0.05. But, the relationship between the knowledge of operating room to fire control methods and the type of jobs were not significant. Also no significant relationship were found between the level of awareness in operating room personnel to fire prevention methods, work experience and job title. .Conclusion: The results indicated that the operating room staff awareness of fire prevention and control methods are low. The results also showed that awareness of fires prevention are lower than the awareness of fire control among the studied personel. Regarding to the potential risk of fire in the operating room, it is suggested

  17. Evaluation of noise pollution level in the operating rooms of hospitals: A study in Iran.

    Science.gov (United States)

    Giv, Masoumeh Dorri; Sani, Karim Ghazikhanlou; Alizadeh, Majid; Valinejadi, Ali; Majdabadi, Hesamedin Askari

    2017-06-01

    Noise pollution in the operating rooms is one of the remaining challenges. Both patients and physicians are exposed to different sound levels during the operative cases, many of which can last for hours. This study aims to evaluate the noise pollution in the operating rooms during different surgical procedures. In this cross-sectional study, sound level in the operating rooms of Hamadan University-affiliated hospitals (totally 10) in Iran during different surgical procedures was measured using B&K sound meter. The gathered data were compared with national and international standards. Statistical analysis was performed using descriptive statistics and one-way ANOVA, t -test, and Pearson's correlation test. Noise pollution level at majority of surgical procedures is higher than national and international documented standards. The highest level of noise pollution is related to orthopedic procedures, and the lowest one related to laparoscopic and heart surgery procedures. The highest and lowest registered sound level during the operation was 93 and 55 dB, respectively. Sound level generated by equipments (69 ± 4.1 dB), trolley movement (66 ± 2.3 dB), and personnel conversations (64 ± 3.9 dB) are the main sources of noise. The noise pollution of operating rooms are higher than available standards. The procedure needs to be corrected for achieving the proper conditions.

  18. 27 CFR 24.166 - Buildings or rooms.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Buildings or rooms. 24.166... OF THE TREASURY LIQUORS WINE Construction and Equipment § 24.166 Buildings or rooms. All buildings or... afford adequate protection to the revenue. Each building or room will be constructed of substantial...

  19. The original appearance of the painted room in the Martenahuis in Franeker

    Directory of Open Access Journals (Sweden)

    Ige Verslype

    2017-09-01

    Full Text Available The Martenahuis in Franeker contains a special room whose walls and ceiling are decorated with vast paintings on canvas. Such fully painted rooms were very popular in the northern Dutch provinces from the last quarter of the seventeenth century and were called ‘painted rooms’ or ‘rooms in the round’. Owing to later additions and alterations, the painted room in the Martenahuis presents a disjointed picture today. The room’s original appearance has been reconstructed with the help of material-technical, art-historical and archival research. It transpires that all the elements of the room were meticulously coordinated with one another, which provides insight into the intentions of the client and the artists involved.The now white-painted flat wooden architectural elements were originally painted with a reddish-brown trompe l’oeil representation which, together with the paintings inserted into them, created the illusion of a richly decorated classical pavilion overlooking Arcadian landscapes. Technical research revealed – in contrast to what the literature had previously suggested – that all the landscape hangings, as well as the central ceiling piece and the eight original wainscot paintings, were part of a single series made especially for this room. Archival research has shown that the room came into being in or shortly after 1701, following the departure in August 1701 of the young Frisian stadholder Johan Willem Friso (1687-1711, who had stayed there while studying at Franeker University. The construction of the room was part of a large-scale renovation commissioned by the wealthy regent Suffridus Westerhuis (1668-1731, who had acquired the building in 1694. Various prints by the French architect Daniel Marot (1661-1752 served as inspiration for the room’s design. Those designs were all published before 1703. There are no elements dating back to Marot’s inventions from or after 1703, such as those included in his collected

  20. A simple intervention to improve patient safety, save time and improve staff experience in the AMU procedure room.

    Science.gov (United States)

    Misselbrook, Gary Peter; Kause, Juliane; Yeoh, Su-Ann

    2016-01-01

    Over the last decade, operating theatres and Intensive Care Units (ICUs) have established systematic methods for performing procedures on patients that have been shown to reduce complications and improve patient safety. Whilst the use of procedure rooms on Acute Medicine Units (AMUs) is highly recommended by patient safety groups and Royal College publications, they are not universally available or appropriately utilised. In this article we discuss a quality improvement project that was undertaken on an AMU at a large university teaching hospital in the United Kingdom, highlighting its successes and challenges.

  1. New Radiation Protection training room

    CERN Multimedia

    HSE Unit

    2013-01-01

    From now on, the theory and practical components of the Radiation Protection training, developed by the RP Group and offered by the HSE Unit’s Safety Training team to people working in a Controlled Radiation Area, will take place in a dedicated teaching room, designed specifically for this kind of training.   The new room is in the Safety Training Centre on the Prévessin site and has been open since 16 October. It has an adjoining workshop that, like the room itself, can accommodate up to 12 people. It is also equipped with an interactive board as well as instruments and detectors to test for ionising radiation. This room is located near the recently inaugurated LHC tunnel mock-up where practical training exercises can be carried out in conditions almost identical to those in the real tunnel. To consult the safety training catalogue and/or sign up for Radiation Protection training, please go to: https://cta.cern.ch For further information, please contact the Safety Trainin...

  2. Measurement of low-frequency noise in rooms

    DEFF Research Database (Denmark)

    Pedersen, Steffen; Møller, Henrik; Persson-Waye, Kerstin

    2006-01-01

    Measurement of low-frequency noise in rooms is problematic due to standing wave patterns. The spatial variation in the sound pressure level can typically be as much as 20-30 dB. For assessment of annoyance from low-frequency noise in dwellings, it is important to measure a level close...... rooms. The sound pressure level was measured 1) in three-dimensional corners and 2) according to current Swedish and Danish measurement methods. Furthermore, the entire sound pressure distributions were measured by scanning. The Swedish and Danish measurement methods include a corner measurement...... to the highest level present in a room, rather than a room average level. In order to ensure representative noise measurements, different positions were investigated based on theoretical considerations and observations from numerical room simulations. In addition measurements were performed in three different...

  3. Perceptual effects in auralization of virtual rooms

    Science.gov (United States)

    Kleiner, Mendel; Larsson, Pontus; Vastfjall, Daniel; Torres, Rendell R.

    2002-05-01

    By using various types of binaural simulation (or ``auralization'') of physical environments, it is now possible to study basic perceptual issues relevant to room acoustics, as well to simulate the acoustic conditions found in concert halls and other auditoria. Binaural simulation of physical spaces in general is also important to virtual reality systems. This presentation will begin with an overview of the issues encountered in the auralization of room and other environments. We will then discuss the influence of various approximations in room modeling, in particular, edge- and surface scattering, on the perceived room response. Finally, we will discuss cross-modal effects, such as the influence of visual cues on the perception of auditory cues, and the influence of cross-modal effects on the judgement of ``perceived presence'' and the rating of room acoustic quality.

  4. Mathematical Models for Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1982-01-01

    A number of different models on the air distribution in rooms are introduced. This includes the throw model, a model on penetration length of a cold wall jet and a model for maximum velocity in the dimensioning of an air distribution system in highly loaded rooms and shows that the amount of heat...... removed from the room at constant penetration length is proportional to the cube of the velocities in the occupied zone. It is also shown that a large number of diffusers increases the amount of heat which may be removed without affecting the thermal conditions. Control strategies for dual duct and single...... duct systems are given and the paper is concluded by mentioning a computer-based prediction method which gives the velocity and temperature distribution in the whole room....

  5. 7 CFR 58.211 - Packaging room for bulk products.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Packaging room for bulk products. 58.211 Section 58... Service 1 Rooms and Compartments § 58.211 Packaging room for bulk products. A separate room or area shall... dust within the packaging room and where needed, a dust collector shall be provided and properly...

  6. Energy conservation by single room control in public buildings dedicated to teaching, e.g. schools, vocational schools, technical universities and universities. Final report; Energieeinsparung durch Einzelraumregelung in oeffentlichen Liegenschaften mit Lehrbetrieb z.B. Schulen, Berufsschulen, Fachhochschulen und Universitaeten. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Nordmann, D.

    2000-07-01

    The energy-saving effect of single-room control of heating systems was investigated. For this purpose, a single-room control system was installed in a university building of 1961, and energy savings were monitored for a 2-year period, with the following results: 1. The potential savings amounted to 28% in both test years. 2. Different operating strategies were used in order to assess the contribution of heating system components. 3. The amortization period is less than 8 years, i.e. much less than the expected life of the systems. 4. Appropriate technical facilities improve the operation and control of a heat supply system in large buildings. 5. Proposals for improving the functionality of single room control systems were developed. 6. Recommendations were given on how to best modernize the control systems of large buildings. 7. The results can be applied to similar buildings as well. [German] Das Forschungsprojekt hatte folgende Ziele: 1. Die Ermittlung des Energie-Einsparpotentials 2. die daraus resultierende Wirtschaftlichkeit 3. die Optimierung der Regelstrategien 4. Erstellung von Handlungsempfehlungen bei der Sanierung mittels Einzelraumregelung. Es wurde in einem Trakt eines aus dem Jahre 1961 stammenden Hochschulgebaeudes, dessen Gebaeudehuelle sich noch in einem unveraenderten Zustand befindet, ein Einzelraumregelsystem mit zugehoeriger Gebaeudeleittechnik (GLT) installiert. Im Rahmen des Forschungsprojekts wurde ueber zwei Heizperioden die damit erreichte Einsparung an Heizenergie untersucht. Im Rahmen des Projektes konnte nachgewiesen werden, dass besonders bei Gebaeuden mit diskontinuierlicher Nutzung die regelungstechnische Sanierung sowohl oekonomisch als auch oekologisch sinnvoll ist. Im Einzelnen konnten die folgenden Ergebnisse ermittelt werden: 1. Es konnte in beiden Heizperioden des Untersuchungszeitraums ein Einsparpotential von ca. 28% nachgewiesen werden. 2. Es wurden unterschiedliche Strategien zum Betrieb des Einzelraumregelsystems

  7. Room acoustic transition time based on reflection overlap

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Brunskog, Jonas; Jacobsen, Finn

    2010-01-01

    A transition time is defined based on the temporal overlap of reflected pulses in room impulse responses. Assuming specular reflections only, the temporal distance between adjacent reflections, which is proportional to the volume of a room, is compared with the characteristic width of a pulse at ...... in a room with nonuniform absorption and furniture than in a room that satisfies the underlying assumptions....

  8. Room acoustic transition time based on reflection overlap

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Brunskog, Jonas; Jacobsen, Finn

    2013-01-01

    A transition time is defined based on the temporal overlap of reflected pulses in room impulse responses. Assuming specular reflections only, the temporal distance between adjacent reflections, which is proportional to the volume of a room, is compared with the characteristic width of a pulse at ...... in a room with nonuniform absorption and furniture than in a room that satisfies the underlying assumptions....

  9. Physics escape room as an educational tool

    Science.gov (United States)

    Vörös, Alpár István Vita; Sárközi, Zsuzsa

    2017-12-01

    Escape rooms have flourished in the last decade. These are adventure games in which players work together to solve puzzles using hints, clues and a strategy to escape from a locked room. In many cases they use different phenomena related to physics. Hence the idea of using escape rooms in science centers or even in classroom activities. Escape rooms are designed for one single team of players, the method is more suitable for activities in a science centre. In our paper, we show that escape rooms' puzzle solving methods could be used in physics classroom activities as well, taking into account that several teams have to work together in the same room/place. We have developed an educational escape game for physics of fluids, as this topic is left out from the Romanian high-school curriculum. We have tried out our game during the project week called "Şcoala altfel" ("school in a different way") and in a physics camp for gifted students. We present the designed physics escape game and the results.

  10. Complete rooming-in care of newborn infants

    Directory of Open Access Journals (Sweden)

    Yoo Min Lee

    2010-05-01

    Full Text Available Purpose : In Kyung Hee East-West Neo Medical Center, Seoul,Korea, efforts to raise rooming-in care success rate have been undertaken since when the hospital was established in 2006. We intended to analyze our experience over the past 3 years of period and to discuss the advantages of rooming-in. Methods : We analyzed the rooming-in practice rate, failure rate, and the breast feeding rate. Subjects were 860 normal healthy neonates from June 2006 to June 2009. Results: Among these 860 cases, 83 babies were required separation out of rooming-in in the middle of the course. Among these 83 cases, 70 cases had to stop the course due to poor condition of babies and 13 cases due to maternal condition. 70 cases of infant’s causes consist of 68 cases of NICU admission and 2 cases of poor feeding support. The other 13 cases of separation include refusal by maternal condition. Therefore the success rate of rooming-in for the last 3 years was 90.3%, that is 777 cases among the total 860 cases. The percentage of exclusive breast feeding was 64%, that of mixed feeding with breast and formula feeding was 25%, and formula feeding only was 11%. Conclusion : We experienced successful rooming-in care for the last 3 years. Nursery facilities should educate and encourage the advantages of rooming-in, including the good formation of attachment between mother and infant, emotional stability, protection from infection, and increased breast feeding rate so that rooming-in care can be fully established.

  11. Foucault could have been an operating room nurse.

    Science.gov (United States)

    Riley, Robin; Manias, Elizabeth

    2002-08-01

    Operating room nursing is an under-researched area of nursing practice. The stereotypical image of operating room nursing is one of task- and technically-orientated aspects of practice, where nurses work in a medical model and are dominated by constraints from outside their sphere of influence. This paper explores the possibility of understanding operating room nursing in a different way. Using the work of Michel Foucault to analyse the work of operating room nursing, this paper argues the relevance of the framework for a more in-depth analysis of this specialty area of practice. The concepts of power, discipline and subjectivity are used to demonstrate how operating room nursing is constructed as a discipline and how operating room nurses act to govern and construct the specialty. Exemplars are drawn from extensive professional experience, from guidelines of professional operating room nursing associations, as well as published texts. The focus is predominantly on the regulation of space and time to maintain the integrity of the sterile surgical field and issues of management, as well as the use of the ethical concept of the 'surgical conscience'. This form of analysis provides a level and depth of inquiry that has rarely been undertaken in operating room nursing. As such, it has the potential to provide a much needed, different view of operation room nursing that can only help to strengthen its professional foundations and development.

  12. Rethinking theatre in modern operating rooms.

    Science.gov (United States)

    Riley, Robin; Manias, Elizabeth

    2005-03-01

    Metaphor is a means through which a widely accepted meaning of a word is used in a different context to add understanding that would otherwise be difficult to conceive. Through etymological and metaphorical associations, we contend that aspects of "theatre" are still relevant in the modern operating rooms and that the use of dramaturgical metaphors can add another layer of understanding about the social reality in this setting. We begin by exploring the historical roots and derivation of the word theatre as it applied to anatomical dissection and surgery. Briefly, we touch on the work of Erving Goffman and examine how his work has been used by others to explore aspects of operating room nursing. Then, drawing on data from a postmodern ethnographic study that has been used to examine communication in operating room nursing, four dramaturgical metaphors are used to illustrate the argument. They are drama, the script and learning the lines, the show must go on, and changing between back stage and front stage. To conclude, the small amount of previously published literature on this topic is compared and contrasted, and the relevance of using dramaturgical metaphors to understand modern operating rooms is discussed. Being able to distinguish between the inherent drama in operating room work and the dramatic realisation of individuals who work within, can help operating room nurses to think differently about, and perhaps re-evaluate their social situation and how they function within it.

  13. Assessment of abuse-related injuries: a comparative study of forensic physicians, emergency room physicians, emergency room nurses and medical students.

    Science.gov (United States)

    Reijnders, Udo J L; Giannakopoulos, Georgios F; de Bruin, Kim H

    2008-01-01

    A comparative study was made investigating whether emergency room physicians, emergency room nurses, forensic physicians, and interns are competent in describing, recognising and determining the possible cause of injuries. The injury assessment scores varied from good--adequate--fail and remained blank in various participant groups. Forensic physicians scored significantly better than emergency room staff and interns in the assessment of abuse-related injuries. There were almost no differences noted between emergency room physicians and emergency room nurses. For the functional group with more or less than 4 to 6 years of experience, no significant differences were noted for scoring good in all 5 cases. The fact that forensic physicians scored better than the emergency room staff is probably explained by the fact that almost all practicing forensic physicians have been officially qualified. Training in this field for all professionals involved in such assessment should be mandatory.

  14. A control room lighting study

    International Nuclear Information System (INIS)

    Vaidya, V.V.; Iwasa-Madge, K.M.; Howard, B.; Willson, R.B.

    1984-01-01

    Operators at a Heavy Water Plant in Ontario, Canada complained about lighting-related difficulties in the control room. The Human Factors Engineering Unit was requested to perform a lighting survey and make recommendations to improve the control centre lighting conditions. This paper describes the control room, the operator tasks, the procedures used for the lighting survey, the findings, and the changes recommended

  15. New thinking for the boiler room.

    Science.gov (United States)

    Rose, Wayne

    2008-09-01

    Wayne Rose, marketing manager at integrated plant room manufacturer Armstrong Integrated Systems, explains how increasing use of off-site manufacture, the latest 3D modelling technology, and advances in control technology, are revolutionising boiler room design and construction.

  16. Role of Magnetocardiography in Emergency Room

    International Nuclear Information System (INIS)

    Kwon, H.; Kim, K.; Kim, J. M.; Lee, Y. H.; Kim, T. E.; Lim, H. K.; Park, Y. K.; Ko, Y. G.; Chung, N.

    2006-01-01

    In emergency rooms, patients with acute chest pain should be diagnosed as quickly as possible with higher diagnostic accuracy for an appropriate therapy to the patients with acute coronary syndrome or for avoiding unnecessary hospital admissions. At present, electrocardiography(ECG) and biochemical markers are generally used to detect myocardial infarction and coronary angiography is used as a gold standard to reveal the degree of narrowing of coronary artery. Magnetocardiography(MCG) has been proposed as a novel and non-invasive diagnostic tool fur the detection of cardiac electrical abnormality associated with myocardial ischemia. In this study, we examined whether the MCG can be used fur the detection of coronary artery disease(CAD) in patients, who were admitted to the emergency room with acute chest pain. MCG was recorded from 36 patients admitted to the emergency room with suspected acute coronary syndrome. The MCG recordings were obtained using a 64-channel SQUID MCG system in a magnetically shielded room. In result, presence of CAD could be found with a sensitivity of 88.2 % in patients with acute chest pain without 57 elevation in ECG, demonstrating a possible use in the emergency room to screen CAD patients.

  17. Revisiting the Operating Room Basics

    Directory of Open Access Journals (Sweden)

    Tushar Chakravorty

    2015-12-01

    Full Text Available Young doctors walking into the operating room are eager to develop their skills to become efficient and knowledgeable professionals in future. But precious little is done to actively develop the basic practical skills of the budding doctors. They remain unaware about the layout of the operating room, the OR etiquette and often do not have sound scientific understanding and importance of meticulous execution of the basic operating room protocols. This article stresses the need to develop the basics of OR protocol and to improve the confidence of the young doctor by strengthening his foundation by showing him that attention to the basics of medical care and empathy for the patient can really make a difference to the outcome of a treatment.

  18. Interdisciplinary trauma room management: staff-related apparative and logistic concepts in three level trauma centers in Europe

    International Nuclear Information System (INIS)

    Kroetz, M.; Linsenmaier, U.; Pfeifer, K.J.; Reiser, M.; Bode, P.J.; Haeuser, H.

    2002-01-01

    Objective. To analyse common and divergent features of staff-related, equipmental and spatial/logistical concepts of three large trauma centers of highest health care level.Methods. The health care mandate as well as the staff management, the organisational and the constructional-spacial structure of trauma room diagnostics and therapy of the trauma centers of the Universities of Leiden and Munich (Innenstadt) and the Zentralklinikum Augsburg are described. In particular the technical equipment and the process of the radiological diagnostic procedures in the trauma room are outlined.Results. Staff availability and basic technical equipment of the trauma rooms are comparable between the three hospitals. Divergent concepts exist concerning the complexity of the initial radiologic examination protocols. Spacial connection and importance of computed tomography are also discussed controversially. Urgent interventional procedures are increasingly performed within the trauma room. Magnetic-resonance-tomography does not play a role in early care from multiple injured patients.Conclusion. Trauma centers have to meet certain personnel and technical prerequisites to guarantee a temporally optimised care for multiple injured patients. Differences between the three centers concerning the logistic sequence and the radiologic examination techniques used are mainly due to variable emphasis put on CT in the initial phase of patient care. (orig.) [de

  19. Residents' reluctance to challenge negative hierarchy in the operating room: a qualitative study.

    Science.gov (United States)

    Bould, M Dylan; Sutherland, Stephanie; Sydor, Devin T; Naik, Viren; Friedman, Zeev

    2015-06-01

    Our aim was to clarify how hierarchy influences residents' reluctance to challenge authority with respect to clearly erroneous medical decision-making. After research ethics approval, we recruited 44 anesthesia residents for a high-fidelity simulation scenario at two Ontario universities. During the scenario, an actor, whom the residents were told was an actual new staff anesthesiologist at their university, asked the trainees to give blood to a Jehovah's Witness in contradiction to the patient's explicitly stated wishes. Following the case, the trainees were debriefed and were interviewed for 30-40 min. The interviews were audio recorded and transcribed verbatim, and the text was coded using a qualitative approach informed by grounded theory. Qualitative analysis of the participants' interviews yielded rich descriptive accounts of hierarchical influences often characterized by fear and intimidation. Residents spoke about their coping strategies, which included adaptability, avoiding conflict, using inquiry as a method for patient advocacy, and relying on a diffusion of responsibility within the larger operating room team. Study results showed that hierarchy played a dominant role in the functioning of the operating room. Participants spoke of both the positive and negative effects of such a hierarchical learning environment. The majority of participants described a negative perception of hierarchy as the norm, and they employed many coping strategies. This study provides insight into how a negative hierarchical culture can adversely impact patient safety, resident learning, and team functioning. We propose a theoretical model to describe challenging authority in this context.

  20. Clean industrial room for drift tube assembling

    International Nuclear Information System (INIS)

    Glonti, G.L.; Gongadze, A.L.; Evtukhovich, P.G.

    2001-01-01

    Description of a clean industrial room for assembly of drift tubes for the muon spectrometer of the ATLAS experiment is presented. High quality specifications on the detectors to be produced demanded creation of a workplace with stable temperature and humidity, as well as minimum quantity of dust in the room. Checking of parameters of intra-room air during long period of continuous work has confirmed correctness of the designed characteristics of the climatic system installed in the clean room. The room large volume (∼ 190 m 3 ), the powerful and flexible climatic system, and simplicity of service allow assembling of detectors with length up to 5 m. Subsequent checking of functionality of the assembled detectors has shown high quality of assembling (the amount of rejected tubes does not exceed 2%). It demonstrates conformity to the assembling quality requirements for mass production of drift chambers for the muon spectrometer. (author)

  1. Clean Industrial Room for Drift Tube Assembling

    CERN Document Server

    Glonti, GL; Evtoukhovitch, P G; Kroa, G; Manz, A; Potrap, I N; Rihter, P; Stoletov, G D; Tskhadadze, E G; Chepurnov, V F; Chirkov, A V; Shelkov, G A

    2001-01-01

    Description of a clean industrial room for assembly of drift tubes for the muon spectrometer of the ATLAS experiment is presented. High quality specifications on the detectors to be produced demanded creation of a workplace with stable temperature and humidity, as well as minimum quantity of dust in the room. Checking of parameters of intra-room air during long period of continuous work has been confirmed correctness of the designed characteristics of the climatic system installed in the clean room. The room large volum (\\sim 190 m^3), the powerful and flexible climatic system, and simplicity of service allow assembling of detectors with length up to 5 m. Subsequent checking of functionality of the assembled detectors has shown high quality of assembling (the amount of rejected tubes does not exceed 2 %). It demonstrates conformity to the assembling quality requirements for mass production of drift chambers for the muon spectrometer.

  2. Control room habitability in Spanish Nuclear Power Plants

    International Nuclear Information System (INIS)

    Mediavilla, F.; Sierra, J. J.

    2007-01-01

    Since the NRC published in 2003 the Generic Letter 2003-01 Control room Habitability and the Regulatory guide 1.197 Demonstrating Control Room Envelope Integrity at Nuclear Power Reactors, where it is emphasized the importance of verifying the control room habitability by means of alternative methods, Spanish Nuclear Power Plants are undertaking the different necessary activities to fulfill the requirements of the regulatory commission. This paper describes the main mechanisms included in NEI 99-03 Nuclear Energy Institute publication Control room Habitability Assessment guidance, to demonstrate and maintain Control room Habitability. In addition, in this article it Ds shown the theoretical principle of the test used to quantify air in-leakage in a control room envelope by using tracer gas techniques. The necessary activities to perform the initial in leakage testing are also put forward. Since 2006 Tecnatom, S. A. has performed the baseline testing in four Spanish Units, all of them with successful results. The rest of the Plants are scheduled to perform the tests during the second half of this year. Finally, this document summarises the more important aspects to be taken into account in the development of control room Habitability Programs, which are expected to ensure the integral maintenance of the Control room Envelope during the life a plant. (Author)

  3. Are Plush Dorms and Fancy Food Plans Important Drivers of College Cost?

    Science.gov (United States)

    Archibald, Robert B.; Feldman, David H.

    2011-01-01

    Like most schools, College of William and Mary is not shy about touting its amenities. The Webpage that advertises the college's housing and dining options begins with, "Wireless and Starbucks? Thomas Jefferson never had it this good." Advertising of this sort is a double-edged public-relations sword. Colleges and universities clearly want to…

  4. Control room and ergonomic design

    International Nuclear Information System (INIS)

    Hinz, W.

    1984-01-01

    The important basis for the configuration of the control room of a nuclear power station is the concept for controlling a fault and that for controlling normal operation. The tasks resulting from this for the control room personnel are decided by the control room concept. In this configuration process (from the division of process control tasks between the system components operators and control technology to the configuration of individual means of operation) the characteristics and capabilities of the personnel, which are subject to special requirements as regards their qualifications, are observed. New concepts which are only now technically feasible are therefore being developed for information processing and display, in order to give the personnel a better oversight of the state and trends of the plant. (orig./DG) [de

  5. Perioperative nursing in public university hospitals

    DEFF Research Database (Denmark)

    Sørensen, Erik Elgaard; Olsen, Ida Østrup; Tewes, Marianne

    2014-01-01

    BACKGROUND: In recent years, perioperative nursing has received ongoing attention as part of an interprofessional collaboration. Perioperative nursing is constantly faced with new challenges and opportunities that necessitate continual updates of nursing knowledge and technical skills. In light...... of the longstanding relationship between nursing and technology, it is interesting that few studies with this focus have been performed. Therefore, our research question was: What is the content of perioperative nursing and how do nurses facilitate the interaction between nursing care and technology in highly...... specialized operating rooms in public university hospitals? METHODS: An ethnography involving participant observations and interviews was conducted during a 9-month study period. The participants comprised 24 nurses from 9 different operating wards at 2 university hospitals in different regions of Denmark...

  6. Epidemiology of rugby injuries sustained by Free State University ...

    African Journals Online (AJOL)

    Background Rugby results in more hospitalisations and visits to the emergency rooms of hospitals than any other sport. It is also the sport with the highest injury rate. The aim of this study was to determine the incidence and profile of the rugby injuries that were sustained by hostel-league rugby players at the University of the ...

  7. New technologies for control room habitability assessment

    International Nuclear Information System (INIS)

    Lahti, G.P.; Muraida, J.E.; Perchiazzi, W.T.; Harden, P.A.

    1994-01-01

    Older nuclear power plants typically considered only a nominal amount of unfiltered inleakage (typically 10 cfm) impacting their postaccident control room habitability. However, recent measurements of unfiltered inleakage show values in excess of the nominal 10 cfm. A reassessment for two of these ''older'' stations has been completed recently to show that the measured inleakage did not jeopardize the safety of the control room occupants. Recent concerns at the Zion Station and the Palisades Station about control room habitability in the event of a loss-of-coolant accident have led to an extensive effort to increase control room habitability margin. The heating, ventilating and air-conditioning (HVAC) system servicing each of the control rooms has the potential for unfiltered in-leakage through many locations. For example, at the Palisades Station, the current limiting control room habitability analysis allows for 25 cfm unfiltered in-leakage through its normal outside air intake louvered isolation dampers during emergency mode into the control room envelope. This leakage value was not thought to be achievable with the existing as-built configuration. Repairing the system was considered a potential solution; however, this would be costly and could negatively affect plant operation. In addition, the system would still be required to meet the low specified unfiltered in-leakage. An alternate approach was to review the analysis and reassess the most important parameters. The key effort was to determine the atmospheric dispersion factors (χ/Qs) through wind tunnel tests using scale models of the stations. The results of the wind tunnel testing could yield more realistic χ/Qs for control room habitability than previously employed methods. The wind tunnel study options were selected based on their ease of implementation, realistic results, and low cost. More importantly, the results of the studies would allow more realistic values of unfiltered inleakage

  8. The radiation dose dilemma in the hybrid operating room

    NARCIS (Netherlands)

    de Ruiter, QMB

    2016-01-01

    The of the hybrid Operation room (an operation room combined with advanced radiological X-ray equipment) is gaining popularity, as it is now the preferred room to perform (complex) endovascular aortic procedures. The fixed C-arms equipped in these rooms make it possible to gain very high image

  9. Nuclear reactor control room construction

    International Nuclear Information System (INIS)

    Lamuro, R.C.; Orr, R.

    1993-01-01

    A control room for a nuclear plant is disclosed. In the control room, objects labelled 12, 20, 22, 26, 30 in the drawing are no less than four inches from walls labelled 10.2. A ceiling contains cooling fins that extend downwards toward the floor from metal plates. A concrete slab is poured over the plates. Studs are welded to the plates and are encased in the concrete. 6 figures

  10. Human-Like Room Segmentation for Domestic Cleaning Robots

    Directory of Open Access Journals (Sweden)

    David Fleer

    2017-11-01

    Full Text Available Autonomous mobile robots have recently become a popular solution for automating cleaning tasks. In one application, the robot cleans a floor space by traversing and covering it completely. While fulfilling its task, such a robot may create a map of its surroundings. For domestic indoor environments, these maps often consist of rooms connected by passageways. Segmenting the map into these rooms has several uses, such as hierarchical planning of cleaning runs by the robot, or the definition of cleaning plans by the user. Especially in the latter application, the robot-generated room segmentation should match the human understanding of rooms. Here, we present a novel method that solves this problem for the graph of a topo-metric map: first, a classifier identifies those graph edges that cross a border between rooms. This classifier utilizes data from multiple robot sensors, such as obstacle measurements and camera images. Next, we attempt to segment the map at these room–border edges using graph clustering. By training the classifier on user-annotated data, this produces a human-like room segmentation. We optimize and test our method on numerous realistic maps generated by our cleaning-robot prototype and its simulated version. Overall, we find that our method produces more human-like room segmentations compared to mere graph clustering. However, unusual room borders that differ from the training data remain a challenge.

  11. Room temperature creep in metals and alloys

    Energy Technology Data Exchange (ETDEWEB)

    Deibler, Lisa Anne [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Materials Characterization and Performance

    2014-09-01

    Time dependent deformation in the form of creep and stress relaxation is not often considered a factor when designing structural alloy parts for use at room temperature. However, creep and stress relaxation do occur at room temperature (0.09-0.21 Tm for alloys in this report) in structural alloys. This report will summarize the available literature on room temperature creep, present creep data collected on various structural alloys, and finally compare the acquired data to equations used in the literature to model creep behavior. Based on evidence from the literature and fitting of various equations, the mechanism which causes room temperature creep is found to include dislocation generation as well as exhaustion.

  12. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft

    2013-01-01

    This paper presents a review of recent developments and future perspectives, addressing the problem of creating a virtual dressing room. First, we review the current state-of-the-art of exiting solutions and discuss their applicability and limitations. We categorize the exiting solutions into three...... kinds: (1) virtual real-time 2D image/video techniques, where the consumer gets to superimpose the clothes on their real-time video to visualize themselves wearing the clothes. (2) 2D and 3D mannequins, where a web-application uses the body measurements provided by the customer, to superimpose...... and their demands to a virtual dressing room....

  13. Low frequency sound field control in rectangular listening rooms using CABS (Controlled Acoustic Bass System) will also reduce sound transmission to neighbor rooms

    DEFF Research Database (Denmark)

    Nielsen, Sofus Birkedal; Celestinos, Adrian

    2011-01-01

    Sound reproduction is often taking place in small and medium sized rectangular rooms. As rectangular rooms have 3 pairs of parallel walls the reflections at especially low frequencies will cause up to 30 dB spatial variations of the sound pressure level in the room. This will take place not only...... at resonance frequencies, but more or less at all frequencies. A time based room correction system named CABS (Controlled Acoustic Bass System) has been developed and is able to create a homogeneous sound field in the whole room at low frequencies by proper placement of multiple loudspeakers. A normal setup...... from the rear wall, and thereby leaving only the plane wave in the room. With a room size of (7.8 x 4.1 x 2.8) m. it is possible to prevent modal frequencies up to 100 Hz. An investigation has shown that the sound transmitted to a neighbour room also will be reduced if CABS is used. The principle...

  14. 7 CFR 58.620 - Freezing and packaging rooms.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Freezing and packaging rooms. 58.620 Section 58.620 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....620 Freezing and packaging rooms. The rooms used for freezing and packaging frozen desserts shall be...

  15. HAMMLAB 1999 experimental control room: design - design rationale - experiences

    International Nuclear Information System (INIS)

    Foerdestroemmen, N. T.; Meyer, B. D.; Saarni, R.

    1999-01-01

    A presentation of HAMMLAB 1999 experimental control room, and the accumulated experiences gathered in the areas of design and design rationale as well as user experiences. It is concluded that HAMMLAB 1999 experimental control room is a realistic, compact and efficient control room well suited as an Advanced NPP Control Room (ml)

  16. THERMAL COMFORT STUDY OF TEACHERS' ROOM AT SEKOLAH BINA MULIA PONTIANAK

    Directory of Open Access Journals (Sweden)

    Albert Suryajaya

    2014-01-01

    Full Text Available Thermal comfort is one of the important aspects to ensure the comfort of a building. School building, e.g. Sekolah Bina Mulia, Pontianak is used for education activities for about eight hours a day. The teachersfourth floor and still applies the natural air ventilation system while other rooms use mechanical ventilation system. It is interesting to see thermal comfort condition in the ort of the room depends on the environment. Because of its position on the fourth floor, the wind circulation can flow freely and the application of air ventilation is possible. The average temperature is 29.599ºC, 71.216% for relative humidity and 0.143 m/s for wind speed, and 29.482ºC for MRT. The average value of PMV is 1.615. The thermal comfort value, based on the average of PPS*(PMV calculation for three days observation is 0.130 and it is the neutral condition. This means the room is comfort for the users and it is mainly because  of the windows, sun shading, and the building materials which support the natural air ventilation of the school   Kenyamanan termal merupakan salah satu aspek penting untuk memastikan suatu bangunan dapat memberikan kenyamanan bagi penggunanya. Bangunan sekolah, seperti Sekolah Bina Mulia Pontianak merupakan bangunan pendidikan yang digunakan kurang lebih delapan jam dalam satu hari. Ruang guru pada sekolah Bina Mulia, yang terletak pada lantai empat masih menggunakan sistem ventilasi udara alami sementara ruangan lain menggunakan sistem penghawaan mekanikal. Kenyamanan termal pada ruangan tentu sangat tergantung pada Keadaan lingkungan. Karena posisinya yang cukup tinggi, pergerakan udara pada ruangan juga lebih bebas. Artinya, aplikasi ventilasi udara alami sangat memungkinkan. Nilai temperatur udara rata-rata pada ruangan adalah 29,599 ºC, kelembaban 71,216%, kecepatan udara 0,143 m/det dan nilai temperatur radiasi 29,482ºC. Nilai PMV rata-rata pada ruangan adalah 1,615. Nilai PPS*(PMV rata-rata pada ruangan

  17. Fast rendering of scanned room geometries

    DEFF Research Database (Denmark)

    Olesen, Søren Krarup; Markovic, Milos; Hammershøi, Dorte

    2014-01-01

    Room acoustics are rendered in Virtual Realities based on models of the real world. These are typically rather coarse representations of the true geometry resulting in room impulse responses with a lack of natural detail. This problem can be overcome by using data scanned by sensors, such as e...

  18. Will there be room for the teaching of internal medicine in a university hospital?

    Science.gov (United States)

    Junod, Alain F

    2002-01-12

    To answer the question addressed, two working groups, one made of the staff of a University clinic, the other one composed of practising general internists, have discussed the assets and weaknesses of a University service of Internal Medicine for postgraduate training. The groups agreed on a number of points: patients' characteristics (complexity and co-morbidities), quality of teaching, method acquisition for clinical reasoning, as well as absence of exposure to ambulatory patients and of follow-up. The groups differed in their views related to the lack of training in psychiatry and psychosocial problems or to hospital dysfunctions. Opening of internal medicine to primary care appears to be necessary at the same time as individual qualities among the senior staff are to be developed, such as critical analysis and self-questioning.

  19. Room climate in large historical rooms. Raumklima in grossen historischen Raeumen; Heizungsart, Heizungsweise, Schadensentwicklung, Schadensverhinderung

    Energy Technology Data Exchange (ETDEWEB)

    Arendt, C

    1993-01-01

    The effects of different types of heating systems in large historical rooms on the room climate, the building and (to some extent) on humans are investigated. Starting from a theoretical analysis and available experimental reports, suitable objects (churches, theatres, festival and assembly halls) were selected in which a number of parameters were measured. From the results criteria were established for judging the different types of heating systems. (BWI). 181 figs.

  20. Significant change in the construction of a door to a room with slowed down neutron field by means of commonly used inexpensive protective materials.

    Science.gov (United States)

    Konefał, Adam; Łaciak, Marcin; Dawidowska, Anna; Osewski, Wojciech

    2014-12-01

    The detailed analysis of nuclear reactions occurring in materials of the door is presented for the typical construction of an entrance door to a room with a slowed down neutron field. The changes in the construction of the door were determined to reduce effectively the level of neutron and gamma radiation in the vicinity of the door in a room adjoining the neutron field room. Optimisation of the door construction was performed with the use of Monte Carlo calculations (GEANT4). The construction proposed in this paper bases on the commonly used inexpensive protective materials such as borax (13.4 cm), lead (4 cm) and stainless steel (0.1 and 0.5 cm on the side of the neutron field room and of the adjoining room, respectively). The improved construction of the door, worked out in the presented studies, can be an effective protection against neutrons with energies up to 1 MeV. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Determination of radon in housing rooms

    International Nuclear Information System (INIS)

    Steger, F.; Sorantin, H.; Kozuh-Schneeberger, J.; Lovranich, E.; Khademi, B.

    1988-03-01

    Radon concentration in 171 apartments with 503 rooms in and around Vienna was measured by a passive measuring system. Polycarbonate foils were exposed during 3 months; the nuclear tracks were visualized by electro-chemical method and evaluated. In housing- and sleeping rooms the mean concentration was 1,03 pCi/l, in cellars 2,15 pCi/l. The equivalent dosis, with 1,03 pCi/l was estimated to 90 mrem/a. At the same time the external radiation dose in the same rooms was measured by TL dosimeters and the dose estimated is again 90 mrem/a. 34 refs., 16 figs., 4 tabs. (qui)

  2. Guidelines for control room systems design. Working material. Report

    International Nuclear Information System (INIS)

    1993-01-01

    This report contains comprehensive technical and methodological information and recommendations for the benefit of Member States for advice and assistance in ''NPP control room systems'' design backfitting existing nuclear power plants and design for future stations. The term ''Control Room Systems'' refers to the entire human/machine interface for the nuclear stations - including the main control room, back-ups control room and the emergency control rooms, local panels, technical support centres, operating staff, operating procedures, operating training programs, communications, etc. Refs, figs and tabs

  3. Clean room actuators

    Energy Technology Data Exchange (ETDEWEB)

    Higuchi, Toshiro

    1987-06-01

    This report explains on the present status of the clean room actuators including the author's research results. In a clean room, there exists a possibility of dust generation, even when a direct human work is eliminated by the use of robots or automatic machines, from the machines themselves. For this, it is important to develop such clean robots and transfer/positioning mechanism that do not generate dusts, and to develop an actuator and its control technique. Topics described in the report are as follows: 1. Prevention of dust diffusion by means of sealing. 2. Elimination of mechanical contact (Linear induction motor and pneumatic float, linear motor and magnetic attraction float, linear motor and air bearing, and magnetic bearing). 3. Contactless actuator having a positioning mechanism (Use of linear step motor and rotary contactless actuator). (15 figs, 11 refs)

  4. Control room habitability study - findings and recommendations

    International Nuclear Information System (INIS)

    Driscoll, J.W.

    1987-01-01

    The Advisory Committee on Reactor Safeguards (ACRS) has raised a number of concerns related to control room habitability and has recommended actions which they believe could alleviate these concerns. As a result of the ACRS's concerns, the US Nuclear Regulatory Commission's (NRC) Office of Nuclear Reactor Regulation (NRR) in conjunction with the Offices of Research and Inspection and Enforcement, and the NRC regional offices, embarked upon a program to reevaluate Control Room Habitability. Argonne National Laboratory was contracted by the NRC to perform a Control Room Habitability Study on twelve licensed power reactors. The plants selected for the study were chosen based upon architect engineer, nuclear steam system supplier, utility, and plant location. The major findings of this study are included in this report along with generic recommendations of the review team that apply to control room HVAC systems. Although the study is not complete, at the time of publication of this report, the results obtained to date should be useful to persons responsible for Control Room Habitability in evaluating their own systems

  5. Control room human engineering influences on operator performance

    International Nuclear Information System (INIS)

    Finlayson, F.C.

    1977-01-01

    Three general groups of factors influence operator performance in fulfilling their responsibilities in the control room: (1) control room and control system design, informational data displays (operator inputs) as well as control board design (for operator output); (2) operator characteristics, including those skills, mental, physical, and emotional qualities which are functions of operator selection, training, and motivation; (3) job performance guides, the prescribed operating procedures for normal and emergency operations. This paper presents some of the major results of an evaluation of the effect of human engineering on operator performance in the control room. Primary attention is given to discussion of control room and control system design influence on the operator. Brief observations on the influences of operator characteristics and job performance guides (operating procedures) on performance in the control room are also given. Under the objectives of the study, special emphasis was placed on the evaluation of the control room-operator relationships for severe emergency conditions in the power plant. Consequently, this presentation is restricted largely to material related to emergency conditions in the control room, though it is recognized that human engineering of control systems is of equal (or greater) importance for many other aspects of plant operation

  6. 7 CFR 58.212 - Hopper or dump room.

    Science.gov (United States)

    2010-01-01

    ....212 Hopper or dump room. A separate room shall be provided for the transfer of bulk dry dairy products to the hoppers and conveyors which lead to the fillers. This room shall meet the same requirements... transfer of dry dairy products from portable bulk bins will be accepted if gasketed surfaces or direct...

  7. 7 CFR 58.413 - Cutting and packaging rooms.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Cutting and packaging rooms. 58.413 Section 58.413....413 Cutting and packaging rooms. When small packages of cheese are cut and wrapped, separate rooms shall be provided for the cleaning and preparation of the bulk cheese and for the cutting and wrapping...

  8. Calculation of Appropriate Minimum Size of Isolation Rooms based on Questionnaire Survey of Experts and Analysis on Conditions of Isolation Room Use

    Science.gov (United States)

    Won, An-Na; Song, Hae-Eun; Yang, Young-Kwon; Park, Jin-Chul; Hwang, Jung-Ha

    2017-07-01

    After the outbreak of the MERS (Middle East Respiratory Syndrome) epidemic, issues were raised regarding response capabilities of medical institutions, including the lack of isolation rooms at hospitals. Since then, the government of Korea has been revising regulations to enforce medical laws in order to expand the operation of isolation rooms and to strengthen standards regarding their mandatory installation at hospitals. Among general and tertiary hospitals in Korea, a total of 159 are estimated to be required to install isolation rooms to meet minimum standards. For the purpose of contributing to hospital construction plans in the future, this study conducted a questionnaire survey of experts and analysed the environment and devices necessary in isolation rooms, to determine their appropriate minimum size to treat patients. The result of the analysis is as follows: First, isolation rooms at hospitals are required to have a minimum 3,300mm minor axis and a minimum 5,000mm major axis for the isolation room itself, and a minimum 1,800mm minor axis for the antechamber where personal protective equipment is donned and removed. Second, the 15 ㎡-or-larger standard for the floor area of isolation rooms will have to be reviewed and standards for the minimum width of isolation rooms will have to be established.

  9. Clinic exam room design: present and future.

    Science.gov (United States)

    Freihoefer, Kara; Nyberg, Gary; Vickery, Christine

    2013-01-01

    This article aims to deconstruct various design qualities and strategies of clinic exam rooms, and discuss how they influence users' interaction and behavior in the space. Relevant literature supports the advantages and disadvantages of different design strategies. Annotated exam room prototypes illustrate the design qualities and strategies discussed. Advancements in technology and medicine, along with new legislative policies, are influencing the way care providers deliver care and ultimately clinic exam room designs. The patient-centered medical home model has encouraged primary care providers to make patients more active leaders of their health plan which will influence the overall functionality and configuration of clinic exam rooms. Specific design qualities discussed include overall size, location of doors and privacy curtains, positioning of exam tables, influence of technology in the consultation area, types of seating, and placement of sink and hand sanitizing dispensers. In addition, future trends of exam room prototypes are presented. There is a general lack of published evidence to support design professionals' design solutions for outpatient exam rooms. Future research should investigate such topics as the location of exam tables and privacy curtains as they relate to patient privacy; typical size and location of consultation table as it relates to patient connection and communication; and placement of sinks and sanitization dispensers as they relate to frequency and patterns of usage. Literature review, outpatient, technology, visual privacy.

  10. Operating Room Utilization at Frederick Memorial Hospital

    National Research Council Canada - National Science Library

    Edwards, Jonathan A

    2007-01-01

    .... A logistical regression analysis was used to identify the impact of variables on operating room utilization rates and therefore help explain how or why some operating rooms incurred higher utilization rates than others...

  11. Control room habitability study: findings and recommendations

    International Nuclear Information System (INIS)

    Driscoll, J.W.

    1986-01-01

    The Advisory Committee on Reactor Safeguards (ACRS) has raised a number of concerns related to control room habitability and has recommended actions which they believe could alleviate these concerns. As a result of the ACRS's concerns, the US Nuclear Regulatory Commission's (NRC) Office of Nuclear Reactor Regulation (NRR) in conjunction with the Offices of Research and Inspection and Enforcement, and the NRC regional offices, embarked upon a program to reevaluate Control Room Habitability. Argonne National Laboratory was contracted by the NRC to perform a Control Room Habitability Study on twelve licensed power reactors. The plants selected for the study were chosen based upon architect engineer, nuclear steam system supplier, utility, and plant location. Participants in the study review the plant design as contained in the Updated Safety Analysis Report, Technical Specifications, Three Mile Island action item III.D.3.4 submittal on Control Room Habitability, NRC staff evaluation of the III.D.3.4 submittal, appropriate plant operating procedures, system drawings, and significant Licensee Event Reports on Loss of Cooling to the Control Room Envelope. A two-day visit is then made to the plant to determine if the as-built systems are built, operated, and surveillance performed as described in the documentation reviewed prior to the visit. The major findings of this study are included in this report along with generic recommendations of the review team that apply to control room HVAC systems. Although the study is not complete, at the time of publication of this report, the results obtained to date should be useful to persons responsible for Control Room Habitability in evaluating their own systems

  12. Microbial air contamination in indoor environment of a university library.

    Science.gov (United States)

    Kalwasińska, Agnieszka; Burkowska, Aleksandra; Wilk, Iwona

    2012-01-01

    The present study was aimed at evaluating the number of bacteria and mould fungi in the indoor and outdoor environment of Toruń University Library. The sampling sites were located in the rooms serving the functions typical of libraries (i.e. in the Main Reading Room, Current Periodicals Reading Room, Collections Conservation Laboratory, Old Prints Storeroom, in rooms serving other (non-library) functions (i.e. main hall, cafeteria, and toilet) as well as outside the library building. The analyses reveal that the concentrations of bacterial as well as fungal aerosols estimated with the use of the impaction method ranged between 10(1)-10(3) CFU·m(-3), which corresponds to the concentrations normally observed in areas of this kind. Evaluation of the hygienic condition of the studied areas was based on the criteria for microbiological cleanliness in interiors submitted by the European Commission in 1993. According to this classification, the air was considered to be heavily or moderately contaminated with bacteria, while the air contamination with mould fungi was described as low or moderate. The air in the Old Prints Storeroom was considered the least contaminated with microbial aerosol.

  13. Durable improvements in efficiency, safety, and satisfaction in the operating room.

    Science.gov (United States)

    Heslin, Martin J; Doster, Barbara E; Daily, Sandra L; Waldrum, Michael R; Boudreaux, Arthur M; Smith, A Blair; Peters, Glenn; Ragan, Debbie B; Buchalter, Scott; Bland, Kirby I; Rue, Loring W

    2008-05-01

    Enhanced productivity and efficiency in the operating room must be balanced with patient safety and staff satisfaction. In December 2004, transition to an expanded replacement hospital resulted in mandatory overtime, unpredictable work hours, and poor morale among operating room (OR) staff. A staff-retention crisis resulted, which threatened the viability of the OR and the institution. We report the changes implemented to efficiently deliver safe patient care in a supportive environment for surgeons and OR staff. University of Alabama at Birmingham University Hospital OR data were evaluated for fiscal year 2004 and compared with fiscal years 2005 and 2006. Case volumes, number of operational ORs, and on-time case starts were evaluated. OR adverse events were tabulated. Percentage of registered nurse hires and staff departures served as a proxy for staff satisfaction. Short, intermediate, and longterm strategies were implemented by an engaged OR management committee with the guidance of surgical, anesthesia, and hospital leadership. These included new block time release policies; use of traveling nurses until new staff could be hired and trained; and incentive-based, voluntary, employee-scheduled overtime. Mandatory nursing education time was blocked weekly. Enforcement of the National Patient Safety Goals were implemented and adjudicated with a "surgeon-of-the-day" system providing backup for nurse management. We demonstrated an increase in operations per year, on-time starts, and registered nurse hires in fiscal years 2005 and 2006. During this same time, we were able to markedly decrease the number of adverse events, admitting delays, and staff departures. Change is difficult to accept but essential when vital clinical activities are impaired and at risk. To maintain important clinical environments like the OR in an academic center, we developed and implemented effective, data-driven changes. This allowed us to retain critical human resources and restore a

  14. Multi-bed patient room architectural evaluation

    Directory of Open Access Journals (Sweden)

    Evangelia Sklavou

    2016-12-01

    Full Text Available Introduction: Leveraging the physical environment’s merits is crucial in healthcare settings towards fostering sustainable healing conditions. In the future, the need to retrofit hospitals already appears more probable than to build new facilities. In Greece, holistic healthcare architecture has significant potential and room to develop. Aim: The architectural research of multi-bed patient room environment. Method: A sample of multi-bed patient rooms of a Greek hospital was studied per architectural documentation and user evaluation survey. Beyond recording the existing situation and user experience, user group differences and the influence of window proximity were studied. The survey sample was based on convenience and comprised 160 patients and 136 visitors. Statistical analysis was performed in SPSS 20, using chi-square exact tests of independence. The chosen level of significance was p < 0.05. Results: Architectural documentation showed that the building morphology had a positive impact in patient rooms, with regard to sunlight penetration and view. Further solar daylight control was deemed necessary, to facilitate overall environmental comfort conditions. High spatial density and considerable disadvantages of the middle patient bed, compared to the one bedside the window and the one further in the back of the room, were also ascertained. User groups did not evaluate their surroundings significantly different, with the exception of ease of access to the view. Window proximity influenced both patients and visitors in evaluating ease of access to the view and visual discomfort. Patients were further affected on window size evaluation and visitors on view related aspects. Conclusions: Synergy between building form and function contributes in creating holistic sustainable healing environments. User evaluation can deviate from objective documentation. Patients and visitors experienced the patient room in a similar manner. The middle bed was

  15. VRML Programs for Room Ventilation Applications

    DEFF Research Database (Denmark)

    Nielsen, Anker

    Cheap 3D models for visualization of room ventilation applications are now available. VRML (Virtu~l Reality Modelling Language) is found to be a good format to describe buildings, rooms and furniture. A 3D model in VRML can be placed on a World Wide Web (www) page and others can see the model...

  16. Mathematical Models for Room Air Distribution - Addendum

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1982-01-01

    A number of different models on the air distribution in rooms are introduced. This includes the throw model, a model on penetration length of a cold wall jet and a model for maximum velocity in the dimensioning of an air distribution system in highly loaded rooms and shows that the amount of heat...... removed from the room at constant penetration length is proportional to the cube of the velocities in the occupied zone. It is also shown that a large number of diffusers increases the amount of heat which may be removed without affecting the thermal conditions. Control strategies for dual duct and single...... duct systems are given and the paper is concluded by mentioning a computer-based prediction method which gives the velocity and temperature distribution in the whole room....

  17. Single room control for user-optimised room air conditions; Einzelraumregelung fuer nutzungsoptimiertes Raumklima

    Energy Technology Data Exchange (ETDEWEB)

    Lezius, A. [Staefa Control System GmbH, Leinfelden-Echterdingen (Germany)

    1995-12-31

    In chapter 14 of the anthology about building control the single room control for achieving user-optimised room air conditions is described. The following aspects are discussed: What is comfort? What is economic efficiency? Systems for secondary air treatment, adapted functions of the measurement and control technique, management functions, orientation of the demand at the use, investment and amortisation. (BWI) [Deutsch] Kapitel 14 des Sammelbandes ueber Building control ist dem Thema der Einzelraumregelung zur Erzielung eines nutzungsoptimierten Raumklimas gewidmet. In diesem Zusammenhang werden folgende Themenbereiche angesprochen: Was ist Komfort? Was ist Wirtschaftlichkeit? Systeme fuer sekundaere Luftbehandlung; Angepasste Funktionen der MSR-Technik; Managementfunktionen; Bedarfsorientierung an der Nutzung; Investition und Amortisation. (BWI)

  18. Recovery room nurses' knowledge regarding postoperative airway ...

    African Journals Online (AJOL)

    Adele

    room nurses in private hospitals in Northern Gauteng, South Af- rica, regarding ... room nurse' is used. The same principle applies when reference is made to the terms ... Ethical considerations. Written consent ..... Principles of CPR in theatre.

  19. DSS / Press Room

    Science.gov (United States)

    Defense Security Service, U.S. Department of Defense Site Map | A-Z Index | Facebook | Twitter Locations Press Room Organizational Structure Careers at DSS Doing Business with DSS Frequently Asked Classification System (NCCS) National Industrial Security System (NISS) ODAA Business Management System (OBMS

  20. Analysis of room acoustics in Danish Hospitals

    DEFF Research Database (Denmark)

    Hoffmann, Ida Ørduk; Zapata Rodriguez, Valentina; Jeong, Cheol-Ho

    2018-01-01

    time (EDT) and T20, and the sound pressure level metrics, namely the equivalent level and peak level. In addition, the staff at the hospitals is asked about their personal perception of the acoustic and noise conditions and the correlation between their subjective disturbances......This project aims to compare room acoustic parameters and noise levels in various Danish hospitals: Odense, Gentofte, Bispebjerg, Hillerød and Aarhus Hospitals. Room acoustic conditions are measured in audiometric rooms at Odense, Gentofte, Bispebjerg and Aarhus hospitals. The noise levels...

  1. What's so Inclusive about an Inclusion Room? Staff Perspectives on Student Participation, Diversity and Equality in an English Secondary School

    Science.gov (United States)

    Gilmore, Gwen

    2012-01-01

    This article by Gwen Gilmore, a lecturer in the School of Curriculum and Pedagogy at Massey University, draws on a research project which explored the nature, extent and characteristics of a disciplinary inclusion room (IR) in a secondary school in the south-west of England using a Cultural Historical Activity Theory framework. In five years to…

  2. Creators Room

    DEFF Research Database (Denmark)

    Iversholt, Lene; Iversholt Toft, Karina

    2012-01-01

    Creators Room er et koncept til daginsitutioner, der indrammer og giver bud på en forståelse mellem inkluderende pædagogik og fysiske rammer. Konceptet er udviklet i et tværfagligt procesforløb, hvor formålet har været at skabe stadig bedre indendørsmiljøer for børn ved at forene pædagogiske...

  3. Human factors methods for nuclear control room design. Volume 2. Human factors survey of control room design practices

    International Nuclear Information System (INIS)

    Seminara, J.L.; Parsons, S.O.

    1979-11-01

    An earlier review of the control rooms of operating nuclear power plants identified many design problems having potential for degrading operator performance. As a result, the formal application of human factors principles was found to be needed. This report demonstrates the use of human factors in the design of power plant control rooms. The approaches shown in the report can be applied to operating power plants, as well as to those in the design stage. This study documents human factors techniques required to provide a sustained concern for the man-machine interface from control room concept definition to system implementation

  4. Screening Criteria for Loss of Room Cooling Failure

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Mee Jeong; Yang, Joon Eon; Yoon, Churl

    2007-01-15

    In this report, we estimated the temperature of the pump rooms and reviewed the operability of the components under the loss of the HVAC (Heating, Ventilation, and Air Condition) system. The issues relevant to the HVAC system in the PSA (Probabilistic Safety Assessment) FT (Fault Tree) model are as follows: (1) Does the loss of the HVAC system bring about a function failure of other components? (2) Can the operator take action to reduce the temperature of the room in case of a HVAC function failure? At present, we do not know whether a component will lose its function or not under the loss of the HVAC. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, 4 under the situation of a loss of the HVAC. Even though we consider this assumption positively, it would be limited to the rooms such as the Switchgear Room, Inverter Room, and Main Control Room etc. where a real recovery action can be performed easily. However, if we consider the HVAC failure in the PSA FT model according to the above background, the problem is that the unavailability induced from the loss of a HVAC is highly unrealistically. From a viewpoint of the PSA, it is not true that the related system always fails even though the HVAC system fails. Therefore, we reviewed the necessity of the HVAC model through the identification of the operable temperature of the components' within the pump room and the change of the temperature of the pump room under the situation of a loss of the HVAC system. In this paper, we performed a heat up calculation for the Auxiliary Feedwater Motor Operated Pump (AFW MDP) room, PAB-077-11A with CFX 10 and RATT when the HVAC system is failed. We also reviewed the operability of the components under a loss of the HVAC. Room

  5. Screening Criteria for Loss of Room Cooling Failure

    International Nuclear Information System (INIS)

    Hwang, Mee Jeong; Yang, Joon Eon; Yoon, Churl

    2007-01-01

    In this report, we estimated the temperature of the pump rooms and reviewed the operability of the components under the loss of the HVAC (Heating, Ventilation, and Air Condition) system. The issues relevant to the HVAC system in the PSA (Probabilistic Safety Assessment) FT (Fault Tree) model are as follows: (1) Does the loss of the HVAC system bring about a function failure of other components? (2) Can the operator take action to reduce the temperature of the room in case of a HVAC function failure? At present, we do not know whether a component will lose its function or not under the loss of the HVAC. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, 4 under the situation of a loss of the HVAC. Even though we consider this assumption positively, it would be limited to the rooms such as the Switchgear Room, Inverter Room, and Main Control Room etc. where a real recovery action can be performed easily. However, if we consider the HVAC failure in the PSA FT model according to the above background, the problem is that the unavailability induced from the loss of a HVAC is highly unrealistically. From a viewpoint of the PSA, it is not true that the related system always fails even though the HVAC system fails. Therefore, we reviewed the necessity of the HVAC model through the identification of the operable temperature of the components' within the pump room and the change of the temperature of the pump room under the situation of a loss of the HVAC system. In this paper, we performed a heat up calculation for the Auxiliary Feedwater Motor Operated Pump (AFW MDP) room, PAB-077-11A with CFX 10 and RATT when the HVAC system is failed. We also reviewed the operability of the components under a loss of the HVAC. Room

  6. Prepare to protect: Operating and maintaining a tornado safe room.

    Science.gov (United States)

    Herseth, Andrew; Goldsmith-Grinspoon, Jennifer; Scott, Pataya

    2017-06-01

    Operating and maintaining a tornado safe room can be critical to the effective continuity of business operations because a firm's most valuable asset is its people. This paper describes aspects of operations and maintenance (O&M) for existing tornado safe rooms as well as a few planning and design aspects that affect the ultimate operation of a safe room for situations where a safe room is planned, but not yet constructed. The information is based on several Federal Emergency Management Agency safe room publications that provide guidance on emergency management and operations, as well as the design and construction of tornado safe rooms.

  7. Delivery room management of term and preterm newly born infants.

    Science.gov (United States)

    Saugstad, Ola Didrik

    2015-01-01

    Delivery room management, especially in the first 'golden' minute, is of the utmost importance. An exact and universal definition of when a baby is born is needed to obtain agreement on what is meant by the first minute of life. Education of young girls is a basic requirement to optimize the health of the mother and baby. Interventions in pregnancy should as far as possible be evidence based. Antenatal care, the selection of birth mode and antenatal steroid therapy when indicated also contribute to obtaining the best outcome. Delayed cord clamping is recommended for both preterm and term infants. However, more data are needed regarding the most immature infants. Routine suctioning of the mouth and airways is not required. Thermal control is important - keep the temperature in the delivery room at 26°C and wrap infants start with CPAP from the first breath. A T-piece device seems to have some advantages compared to self-inflating bags. Surfactant instillation is often not needed prophylactically provided the mother has received antenatal steroids. Less invasive methods for administering surfactant may be useful. If ventilatory support is needed, start with air in term and near-term infants. For babies of 29-33 weeks of gestation start with 21-30% oxygen and for infants start with 30% oxygen and adjust according to the response obtained. © 2015 S. Karger AG, Basel.

  8. RLA room 20 cleanout and stabilization

    International Nuclear Information System (INIS)

    Ham, J.E.

    1997-01-01

    This engineering report documents the decontamination and stabilization of the Rupture Loop Annex located in room 20 of the 309 building's Plutonium Recycle Test Reactor. Low level, mixed, and recyclable waste was removed from the room. Smearable contamination was removed and/or fixed in place with paint. The RLA was cleaned out and stabilized to meet the Environmental Restoration Contractor's turnover criteria

  9. Perception of tomorrow's nuclear power plant control rooms

    International Nuclear Information System (INIS)

    Meyer, O.R.

    1986-01-01

    Major development programs are upgrading today's light water reactor nuclear power plant (NPP) control rooms. These programs involve displays, control panel architecture, procedures, staffing, and training, and are supported by analytical efforts to refine the definitions of the dynamics and the functional requirements of NPP operation. These programs demonstrate that the NPP control room is the visible command/control/communications center of the complex man/machine system that operates the plant. These development programs are primarily plant specific, although the owners' groups and the Institute of Nuclear Power Operations (INPO) do provide some standardization. The Idaho National Engineering Laboratory recently completed a project to categorize control room changes and estimate the degree of change. That project, plus related studies, provides the basis for this image of the next generation of NPP control rooms. The next generation of NPP control rooms is envisioned as being dominated by three current trends: (1) application of state-of-the-art computer hardware and software; (2) use of NPP dynamic analyses to provide the basis for the control room man/machine system design; and (3) application of empirical principles of human performance

  10. Improving the Interdisciplinary Team Work in the Operating Room

    DEFF Research Database (Denmark)

    Tørring, Birgitte

    In surgical teams, where health professionals are highly interdependent and work under time pressure, it is of particular importance that the team work is well-functioning to secure treatment quality and patient safety. Using the theory of relational coordination (RC) may be the key to unlocking...... the black box of teamwork in search for relational elements critical to successful collaboration and communication. Few single studies exists which explore how RC could be observed and improved in this context. The present study examines surgical teams in selected operating rooms (OR) focusing on RC...... period in 2014 in two orthopedic surgical wards in a university hospital. A directed content analysis on the basis of theory of RC is used to transform the data to show different typologies of interdisciplinary team work. RC was subsequently measured using the RC Survey. Data describe very complex...

  11. Active low frequency sound field control in a listening room using CABS (Controlled Acoustic Bass System) will also reduce the sound transmitted to neighbour rooms

    DEFF Research Database (Denmark)

    Nielsen, Sofus Birkedal; Celestinos, Adrian

    2012-01-01

    Sound in rooms and transmission of sound between rooms gives the biggest problems at low frequencies. Rooms with rectangular boundaries have strong resonance frequencies and will give big spatial variations in sound pressure level (SPL) in the source room, and an increase in SPL of 20 dB at a wall...... Bass System) is a time based room correction system for reproduced sound using loudspeakers. The system can remove room modes at low frequencies, by active cancelling the reflection from at the rear wall to a normal stereo setup. Measurements in a source room using CABS and in two neighbour rooms have...... shown a reduction in sound transmission of up to 10 dB at resonance frequencies and a reduction at broadband noise of 3 – 5 dB at frequencies up to 100 Hz. The ideas and understanding of the CABS system will also be given....

  12. Aspectos biométricos de frutos e sementes, grau de umidade e superação de dormência de jatobá = Biometric aspects of fruit and seeds, moisture content and overcoming of the dormancy in jatoba

    Directory of Open Access Journals (Sweden)

    Leonaldo Alves de Andrade

    2010-04-01

    Full Text Available Este trabalho objetivou caracterizar biometricamente sementes e frutos de Hymenaea courbaril L. e determinar o grau de umidade, bem como avaliar diferentes tratamentos de superação de dormência. Foram determinados a biometria, a massa de frutos e sementes e o número de sementes por fruto. As sementes foram submetidas aos seguintescortes: 1-testemunha, sem escarificação ou corte; 2-escarificação em três faces; 3-corte ao meio e 4-corte em quatro partes. Avaliou-se também o percentual de emergência, o IVE, o comprimento da parte aérea e da raiz de plântulas. Para isso, as sementes foram submetidasà superação de dormência, com e sem embebição em água, pelos seguintes tratamentos: Iescarificação do lado oposto ao hilo; II-escarificação em uma lateral; III-escarificação em duas laterais; IV-escarificação em uma lateral e no lado oposto ao hilo; V-escarificação em duas laterais e no lado oposto ao hilo; VI-Testemunha, sem escarificação. O comprimento, a largura, o diâmetro e a massa média dos frutos foram 115,7 mm; 62,18 mm; 43,8 mm e 183,85 g, respectivamente. Para a determinação da umidade, deve-se cortar as sementes em pelo menos duas partes. A escarificação, independentemente da posição na semente, com ou sem embebição em água, possibilita maior qualidade fisiológica.This study aimed to characterize biometrical seeds and fruits ofHymenaea courbaril L., determine the moisture content and assess different treatments to overcome dormancy. Fruit biometry, mass of fruits and seeds, and the number of seeds per fruit were determined. The seeds were submitted to the following treatments: 1-control, without cutting or scarification, 2-scarification on three sides, 3-cut in half and 4-cut in four parts. The percentage of emergence, emergence speed index, length of the buds and root of seedlings werealso evaluated. So, the seeds were submitted to overcome dormancy, with and without soaking in water, represented by

  13. Room-temperature antiferromagnetic memory resistor.

    Science.gov (United States)

    Marti, X; Fina, I; Frontera, C; Liu, Jian; Wadley, P; He, Q; Paull, R J; Clarkson, J D; Kudrnovský, J; Turek, I; Kuneš, J; Yi, D; Chu, J-H; Nelson, C T; You, L; Arenholz, E; Salahuddin, S; Fontcuberta, J; Jungwirth, T; Ramesh, R

    2014-04-01

    The bistability of ordered spin states in ferromagnets provides the basis for magnetic memory functionality. The latest generation of magnetic random access memories rely on an efficient approach in which magnetic fields are replaced by electrical means for writing and reading the information in ferromagnets. This concept may eventually reduce the sensitivity of ferromagnets to magnetic field perturbations to being a weakness for data retention and the ferromagnetic stray fields to an obstacle for high-density memory integration. Here we report a room-temperature bistable antiferromagnetic (AFM) memory that produces negligible stray fields and is insensitive to strong magnetic fields. We use a resistor made of a FeRh AFM, which orders ferromagnetically roughly 100 K above room temperature, and therefore allows us to set different collective directions for the Fe moments by applied magnetic field. On cooling to room temperature, AFM order sets in with the direction of the AFM moments predetermined by the field and moment direction in the high-temperature ferromagnetic state. For electrical reading, we use an AFM analogue of the anisotropic magnetoresistance. Our microscopic theory modelling confirms that this archetypical spintronic effect, discovered more than 150 years ago in ferromagnets, is also present in AFMs. Our work demonstrates the feasibility of fabricating room-temperature spintronic memories with AFMs, which in turn expands the base of available magnetic materials for devices with properties that cannot be achieved with ferromagnets.

  14. The Operating Room of the Future Versus the Future of the Operating Room.

    Science.gov (United States)

    Kassam, Amin B; Rovin, Richard A; Walia, Sarika; Chakravarthi, Srikant; Celix, Juanita; Jennings, Jonathan; Khalili, Sammy; Gonen, Lior; Monroy-Sosa, Alejandro; Fukui, Melanie B

    2017-06-01

    Technological advancement in the operating room is evolving into a dynamic system mirroring that of the aeronautics industry. Through data visualization, information is continuously being captured, collected, and stored on a scalable informatics platform for rapid, intuitive, iterative learning. The authors believe this philosophy (paradigm) will feed into an intelligent informatics domain fully accessible to all and geared toward precision, cell-based therapy in which tissue can be targeted and interrogated in situ. In the future, the operating room will be a venue that facilitates this real-time tissue interrogation, which will guide in situ therapeutics to restore the state of health. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Cosmology the homogeneous universe and the evolution of structures

    CERN Multimedia

    CERN. Geneva. Audiovisual Unit

    2003-01-01

    In my course I will first give and introduction to standard cosmology. I discuss the equations of the homogeneous and isotropic universe and I'll briefly summarize its thermal history. After that I want to concentrate on the fluctuations in the universe. We will study anisotropies in the cosmic microwave background, fluctuations of the matter density and the velocity field and weak lensing. I want to explain especially new cosmological data which are coming up right now and their implication for the cosmological model. N.B. This lecture series will be held in the Auditorium, bldg. 500 on 27, 28, 30, 31 January and in the Council room on 29 January.

  16. The investigation of the design of hybrid operating room

    International Nuclear Information System (INIS)

    Jiang Weihao; Li Jun

    2011-01-01

    Objective: To investigate the design of the interventional operating room that can meet the needs of modern DSA operation, and the overall arrangement of the hybrid operating room should be reasonable, practical and perspective. Methods: The experience and understanding obtained from the designing and planning of the new Building of Radiology and Surgery in authors' hospital were summarized. In order to meet the requirements of aseptic surgical practices and a full-featured hybrid operating room the following factors should be carefully and synthetically taken into account: the room size, the functional sub-areas, the operational procedures, the aseptic specification, etc. Results: The sufficient verification and scientific design were the important link for building a hybrid operating room. It could provide the surgeons and interventional physicians with more alternative operating methods and it could represent the development trend of medical technology. Conclusion: When planning and designing a new DSA operating room, various factors related to the interventional procedures, such as the room size, the functional sub-areas, the operational procedures and the aseptic specification, should be carefully and synthetically taken into account. The standard of aseptic procedure must be strictly complied with and the various functional sub-areas need to be rationally distributed. The design of hybrid operating room, which joins the functions of both open surgery and interventional management together, should be scientific, practical and perspective. (authors)

  17. Gaining control room habitability margin at the Palisades Plant

    International Nuclear Information System (INIS)

    Harden, P.A.

    1993-01-01

    The bounding design-basis accident for control room habitability is the loss-of-coolant accident (LOCA). At Palisades, very little margin existed between the calculated control room operator thyroid dose and the 0.3-Sv (30-rem) limit of Standard Review Plan (SRP) 6.4. Also, a low rate of unfiltered air leakage into the control room during the emergency mode of operation, 5.5 x 10 -3 m 3 /s (11.6 ft 3 /min), was accounted for in the control room habitability analysis. The control room heating, ventilating and air-conditioning system at Palisades has louvered isolation dampers for the normal air intake that are exposed to a negative pressure. Considering the small margin to the thyroid dose limits and the leakage characteristics of louvered dampers, a low allowable rate of unfiltered air in-leakage raised some concern. A significant effort has been initiated to alleviate control room habitability concerns at Palisades. The first step in this effort was to evaluate the calculational models for control room habitability and gain margin through updated analytical methods. To accomplish this, a new radiological consequence analysis for the LOCA was completed

  18. Air change. Ventilation requirements of closed rooms

    Energy Technology Data Exchange (ETDEWEB)

    Cords, W

    1988-04-01

    Closed rooms have to be ventilated in order to compensate influences changing the composition and quality of air. Details are given on the conditions and factors determining the required change of air as well as the design of ventilation systems. Reference is made to the respiratory consumption of oxygen, the increase of hazardous carbon dioxide contents causing headaches and indispositions, water vapor exhalations, body heat, odors, cold air coming in from outside, bodily heat losses, carbon dioxide limiting values, air speeds, and air pressures inside rooms. The humidity and temperatures of frequented rooms should keep within the maximum values. (HWJ).

  19. Assessment of daylight quality in simple rooms

    DEFF Research Database (Denmark)

    Johnsen, Kjeld; Dubois, Marie-Claude; Sørensen, Karl Grau

    The present report documents the results of a study on daylight conditions in simple rooms of residential buildings. The overall objective of the study was to develop a basis for a method for the assessment of daylight quality in a room with simple geometry and window configurations. As a tool...... in daylighting conditions for a number of lighting parameters. The results gave clear indications of, for instance, which room would be the brightest, under which conditions might glare be a problem and which type of window would yield the greatest luminous variation (or visual interest), etc....

  20. Local control room

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Local control room in the ejection building : all electronics pertaining to proton distribution and concomitants such as beam gymnastics and diagnostics at high energies will eventually be gathered here. Shown is the first of two rows of fast ejection electronic racks. It includes only what is necessary for operation.

  1. Atmospheric diffusion model for control room habitability assessments

    International Nuclear Information System (INIS)

    Ramsdell, J.V.; Lee, J.Y.

    1993-01-01

    General Design Criterion 19 for nuclear power plants (Appendix A to 10CFR50) requires control room radiation protection adequate to limit radiation exposures to control room personnel. Murphy and Campe proposed the procedure currently used in evaluating control room habitability. However, data from building-wake diffusion experiments at nuclear power plants indicate that the Murphy-Campe procedure tends to overestimate concentrations, particularly during low wind speeds. This paper describes an alternative procedure developed by the Pacific Northwest Laboratory that is acceptable to U.S. Nuclear Regulatory Commission (NRC) staff. The procedure estimates control room air intake concentrations that are generally lower than those estimated by the Murphy-Campe procedure, yet are still conservative

  2. Control room inleakage testing using tracer gases at Zion Generating station

    International Nuclear Information System (INIS)

    Lagus, P.L.; Brown, J.H.; Dubois, L.J.; Fleming, K.M.

    1993-01-01

    In order to assess the amount of air inleakage into the Control Room Envelope at Zion Generating Station (ZGS), a series of tracer gas tests using sulfur hexafluoride (SF 6 ) were performed on the Control Room ventilation system (PV system) and the Computer Room/Miscellaneous Area ventilation system (OV system) during February, 1991. Two redundant trains, denoted A and B comprise the PV system. Inleakage was measured for each train. An OV supply duct passes through the Control Room Envelope. Leakage from this duct into the Control Room would constitute air leakage into the Control room Envelope and hence any potential leakage had to be quantified. Each test attempted to measure the contribution (if any) of a particular section of PV return duct or OV supply duct to the total air inleakage into the Control Room. This paper reviews the tracer gas tests. Described here are the control room inleakage testing, HVAC equipment room duct inleakage, purge plenum inleakage, OV duct leakage into the control room envelope, vestibule PV return inleakage, TSC duct inleakage, and cable spreading room inleakage. Conclusions from the testing are presented. 5 refs., 4 figs., 7 tabs

  3. Using micro saint to predict performance in a nuclear power plant control room

    International Nuclear Information System (INIS)

    Lawless, M.T.; Laughery, K.R.; Persenky, J.J.

    1995-09-01

    The United States Nuclear Regulatory Commission (NRC) requires a technical basis for regulatory actions. In the area of human factors, one possible technical basis is human performance modeling technology including task network modeling. This study assessed the feasibility and validity of task network modeling to predict the performance of control room crews. Task network models were built that matched the experimental conditions of a study on computerized procedures that was conducted at North Carolina State University. The data from the open-quotes paper proceduresclose quotes conditions were used to calibrate the task network models. Then, the models were manipulated to reflect expected changes when computerized procedures were used. These models' predictions were then compared to the experimental data from the open-quotes computerized conditionsclose quotes of the North Carolina State University study. Analyses indicated that the models predicted some subsets of the data well, but not all. Implications for the use of task network modeling are discussed

  4. 7 CFR 58.313 - Print and bulk packaging rooms.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Print and bulk packaging rooms. 58.313 Section 58.313 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....313 Print and bulk packaging rooms. Rooms used for packaging print or bulk butter and related products...

  5. Multinodal control room envelope model used for habitability analysis

    International Nuclear Information System (INIS)

    Blumberg, W.M.; Gore, D.E.

    1995-01-01

    This work analyzes the habitability of the control room envelope (CRE) during an off-normal ventilation system condition. The most limiting design basis accident utilized for this analysis is the postulated loss-of-coolant accident. The off-normal condition assumes two rooms within the CRE are at pressures that are lower than adjoining rooms outside the CRE. This pressure differential allows unfiltered in-leakage to enter the CRE through the doors and penetrations in these rooms. This paper quantifies the maximum unfiltered in-leakage

  6. Survey of licensee control room habitability practices

    International Nuclear Information System (INIS)

    Boland, J.F.; Brookshire, R.L.; Danielson, W.F.; Driscoll, J.W.; Graham, E.D.; McConnell, R.J.; Thompson, V.N.

    1985-04-01

    This document presents the results of a survey of Licensee control-room-habitability practices. The survey is part of a comprehensive program plan instituted in August 1983 by the NRC to respond to ongoing questions from the Advisory Committee on Reactor Safeguards (ACRS). The emphasis of this survey was to determine by field review the control-room habitability practices at three different plants, one of which is still under construction and scheduled to receive an operating license in 1986. The other two plants are currently operating, having received operating licenses in the mid-1970's and early 1980's. The major finding of this survey is that despite the fact that the latest control-room-habitability systems have become larger and more complex than earlier systems surveyed, the latest systems do not appear to be functionally superior. The major recommendation of this report is to consolidate into a single NRC document, based upon a comprehensive systems engineering approach, the pertinent criteria for control-room-habitability design

  7. Modelling aerosol transfer in a ventilated room

    International Nuclear Information System (INIS)

    Nerisson, Ph.

    2009-02-01

    When particulate radioactive contamination is likely to become airborne in a ventilated room, assessment of aerosol concentration in every point of this room is important, in order to ensure protection of operators and supervision of workspaces. Thus, a model of aerosol transport and deposition has been developed as part of a project started with IRSN, EDF and IMFT. A simplified Eulerian model, called 'diffusion-inertia model' is used for particle transport. It contains a single transport equation of aerosol concentration. The specific study of deposition on walls has permitted to develop a boundary condition approach, which determines precisely the particle flux towards the wall in the boundary layer, for any deposition regime and surface orientation.The final transport and deposition models retained have been implemented in a CFD code called Code-Saturne. These models have been validated according to literature data in simple geometries and tracing experiments in ventilated rooms, which have been carried out in 30 m 3 and 1500 m 3 laboratory rooms. (author)

  8. Comparison of two whole-room ultraviolet irradiation systems for enhanced disinfection of contaminated hospital patient rooms.

    Science.gov (United States)

    Ali, S; Yui, S; Muzslay, M; Wilson, A P R

    2017-10-01

    Ultraviolet (UV) light decontamination systems are being used increasingly to supplement terminal disinfection of patient rooms. However, efficacy may not be consistent in the presence of soil, especially against Clostridium difficile spores. To demonstrate in-use efficacy of two whole-room UV decontamination systems against three hospital pathogens with and without soil. For each system, six patient rooms were decontaminated with UV irradiation (enhanced disinfection) following manual terminal cleaning. Total aerobic colony counts of surface contamination were determined by spot-sampling 15 environmental sites before and after terminal disinfection and after UV irradiation. Efficacy against biological indicator coupons (stainless-steel discs) was performed for each system using test bacteria (10 6  cfu EMRSA-15 variant A, carbapenemase-producing Klebsiella pneumoniae) or spores (10 5  cfu C. difficile 027), incorporating low soiling [0.03% bovine serum albumin (BSA)], heavy soiling (10% BSA) or synthetic faeces (C. difficile only) placed at five locations in the room. UV disinfection eliminated contamination after terminal cleaning in 8/14 (57%) and 11/14 (79%) sites. Both systems demonstrated 4-5 log 10 reductions in meticillin-resistant Staphylococcus aureus and K. pneumoniae at low soiling. Lower and more variable log 10 reductions were achieved when heavy soiling was present. Between 0.1 and 4.8 log 10 reductions in C. difficile spores were achieved with low but not heavy soil challenge. Terminal disinfection should be performed on all surfaces prior to UV decontamination. In-house validation studies should be considered to ensure optimal positioning in each room layout and sufficient cycle duration to eliminate target pathogens. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. Monitoring proton radiation therapy with in-room PET imaging

    International Nuclear Information System (INIS)

    Zhu Xuping; Ouyang Jinsong; El Fakhri, Georges; Espana, Samuel; Daartz, Juliane; Liebsch, Norbert; Paganetti, Harald; Bortfeld, Thomas R

    2011-01-01

    We used a mobile positron emission tomography (PET) scanner positioned within the proton therapy treatment room to study the feasibility of proton range verification with an in-room, stand-alone PET system, and compared with off-line equivalent studies. Two subjects with adenoid cystic carcinoma were enrolled into a pilot study in which in-room PET scans were acquired in list-mode after a routine fractionated treatment session. The list-mode PET data were reconstructed with different time schemes to generate in-room short, in-room long and off-line equivalent (by skipping coincidences from the first 15 min during the list-mode reconstruction) PET images for comparison in activity distribution patterns. A phantom study was followed to evaluate the accuracy of range verification for different reconstruction time schemes quantitatively. The in-room PET has a higher sensitivity compared to the off-line modality so that the PET acquisition time can be greatly reduced from 30 to 15 O component and lower biological washout. For soft tissue-equivalent material, the distal fall-off edge of an in-room short acquisition is deeper compared to an off-line equivalent scan, indicating a better coverage of the high-dose end of the beam. In-room PET is a promising low cost, high sensitivity modality for the in vivo verification of proton therapy. Better accuracy in Monte Carlo predictions, especially for biological decay modeling, is necessary.

  10. Speaker comfort and increase of voice level in lecture rooms

    DEFF Research Database (Denmark)

    Brunskog, Jonas; Gade, Anders Christian; Bellester, G P

    2008-01-01

    Teachers often suffer health problems or tension related to their voice. These problems may be related to there working environment, including room acoustics of the lecture rooms which forces them to stress their voices. The present paper describes a first effort in finding relationships between...... were also measured in the rooms and subjective impressions from about 20 persons who had experience talking in these rooms were collected as well. Analysis of the data revealed significant differences in the sound power produced by the speaker in the different rooms. It was also found...

  11. Operation Aspect of the Main Control Room of NPP

    International Nuclear Information System (INIS)

    Sahala M Lumbanraja

    2009-01-01

    The main control room of Nuclear Power Plant (NPP) is operational centre to control all of the operation activity of NPP. NPP must be operated carefully and safely. Many aspect that contributed to operation of NPP, such as man power whose operated, technology type used, ergonomic of main control room, operational management, etc. The disturbances of communication in control room must be anticipated so the high availability of NPP can be achieved. The ergonomic of the NPP control room that will be used in Indonesia must be designed suitable to anthropometric of Indonesia society. (author)

  12. Uncertainty of input data for room acoustic simulations

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Marbjerg, Gerd; Brunskog, Jonas

    2016-01-01

    Although many room acoustic simulation models have been well established, simulation results will never be accurate with inaccurate and uncertain input data. This study addresses inappropriateness and uncertainty of input data for room acoustic simulations. Firstly, the random incidence absorption...... and scattering coefficients are insufficient when simulating highly non-diffuse rooms. More detailed information, such as the phase and angle dependence, can greatly improve the simulation results of pressure-based geometrical and wave-based models at frequencies well below the Schroeder frequency. Phase...... summarizes potential advanced absorption measurement techniques that can improve the quality of input data for room acoustic simulations. Lastly, plenty of uncertain input data are copied from unreliable sources. Software developers and users should be careful when spreading such uncertain input data. More...

  13. Intrahospital teleradiology from the emergency room

    Science.gov (United States)

    Fuhrman, Carl R.; Slasky, B. S.; Gur, David; Lattner, Stefanie; Herron, John M.; Plunkett, Michael B.; Towers, Jeffrey D.; Thaete, F. Leland

    1993-09-01

    Off-hour operations of the modern emergency room presents a challenge to conventional image management systems. To assess the utility of intrahospital teleradiology systems from the emergency room (ER), we installed a high-resolution film digitizer which was interfaced to a central archive and to a workstation at the main reading room. The system was designed to allow for digitization of images as soon as the films were processed. Digitized images were autorouted to both destinations, and digitized images could be laser printed (if desired). Almost real time interpretations of nonselected cases were performed at both locations (conventional film in the ER and a workstation in the main reading room), and an analysis of disagreements was performed. Our results demonstrate that in spite of a `significant' difference in reporting, `clinically significant differences' were found in less than 5% of cases. Folder management issues, preprocessing, image orientation, and setting reasonable lookup tables for display were identified as the main limitations to the systems' routine use in a busy environment. The main limitation of the conventional film was the identification of subtle abnormalities in the bright regions of the film. Once identified on either system (conventional film or soft display), all abnormalities were visible and detectable on both display modalities.

  14. Spatial Hearing with Incongruent Visual or Auditory Room Cues

    Science.gov (United States)

    Gil-Carvajal, Juan C.; Cubick, Jens; Santurette, Sébastien; Dau, Torsten

    2016-11-01

    In day-to-day life, humans usually perceive the location of sound sources as outside their heads. This externalized auditory spatial perception can be reproduced through headphones by recreating the sound pressure generated by the source at the listener’s eardrums. This requires the acoustical features of the recording environment and listener’s anatomy to be recorded at the listener’s ear canals. Although the resulting auditory images can be indistinguishable from real-world sources, their externalization may be less robust when the playback and recording environments differ. Here we tested whether a mismatch between playback and recording room reduces perceived distance, azimuthal direction, and compactness of the auditory image, and whether this is mostly due to incongruent auditory cues or to expectations generated from the visual impression of the room. Perceived distance ratings decreased significantly when collected in a more reverberant environment than the recording room, whereas azimuthal direction and compactness remained room independent. Moreover, modifying visual room-related cues had no effect on these three attributes, while incongruent auditory room-related cues between the recording and playback room did affect distance perception. Consequently, the external perception of virtual sounds depends on the degree of congruency between the acoustical features of the environment and the stimuli.

  15. Evaluation of noise level in architecture department building in University of Sumatera Utara

    Science.gov (United States)

    Amran, Novrial; Damanik, Novita Hillary Christy

    2018-03-01

    Noise is one the comfort factors that need to be noticed, particularly in an educational environment. Hearing a high noise in a period can affect students’ learning performance. The aims of this study were to know the noise level and get an appropriate design to reduce noise in Architecture Department building in the University of Sumatera Utara, considering that architecture students often spend most of their time inside the room. The measurement was conducted in four rooms for two days each from 09:00 – 12:00 and from 13:00 – 16:00 by using Sound Level Meter that placed near the noise source of the room. The result indicated that the average of noise level exceeded the 55 dB(A) so it still needs the appropriate design to reduce the noise that occurs in the building.

  16. The Clock Is Ticking: Library Orientation as Puzzle Room

    Science.gov (United States)

    Reade, Tripp

    2017-01-01

    Tripp Reade is the school librarian at Cardinal Gibbons High School in Raleigh, North Carolina. This article describes how he redesigned his school's library orientation program after learning about escape rooms and a variant known as puzzle rooms. Puzzle rooms present players with a set of challenges to solve; they require "teamwork,…

  17. Personal Exposure in Displacement Ventilated Rooms

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter Vilhelm

    1996-01-01

    in the lower part of the room close to the occupant. A personal exposure model for displacement ventilated rooms is proposed. The model takes the influence of gradients and the human thermal boundary layer into account. Two new quantities describing the interaction between a person and the ventilation......Personal exposure in a displacement ventilated room is examined. The stratified flow and the considerable concentration gradients necessitate an improvement of the widely used fully mixing compartmental approach. The exposure of a seated and a standing person in proportion to the stratification...... contaminant sources, this entrainment improves the indoor air quality. Measurements of exposure due to a passive contaminant source show a significant dependence on the flow field as well as on the contaminant source location. Poor system performance is found in the case of a passive contaminant released...

  18. 9 CFR 590.522 - Breaking room operations.

    Science.gov (United States)

    2010-01-01

    ... personnel. (m) Ingredients and additives used in, or for, processing egg products, shall be handled in a..., Processing, and Facility Requirements § 590.522 Breaking room operations. (a) The breaking room shall be kept... clean and reasonably dry during breaking operations and free of egg meat and shells. (b) All breaking...

  19. 13 CFR 102.2 - Public reading rooms.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Public reading rooms. 102.2 Section 102.2 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION RECORD DISCLOSURE AND PRIVACY... described in paragraph (a) of this section are available in the SBA Online Reading Room at http://www.sba...

  20. Radiation protection in the operating room

    International Nuclear Information System (INIS)

    Kunz, B.; Stargardt, A.

    1978-01-01

    On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low

  1. Acuity-adaptable nursing care: exploring its place in designing the future patient room.

    Science.gov (United States)

    Kwan, Melissa A

    2011-01-01

    To substantiate the anticipated benefits of the original acuity-adaptable care delivery model as defined by innovator Ann Hendrich. In today's conveyor belt approach to healthcare, upon admission and through discharge, patients are commonly transferred based on changing acuity needs. Wasted time and money and inefficiencies in hospital operations often result-in addition to jeopardizing patient safety. In the last decade, a handful of hospitals pioneered the implementation of the acuity-adaptable care delivery model. Built on the concept of eliminating patient transfers, the projected outcomes of acuity-adaptable units-decreased average lengths of stay, increased patient safety and satisfaction, and increased nurses' satisfaction from reduced walking distances-make a good case for a model patient room. Although some hospitals experienced the projected benefits of the acuity-adaptable care delivery model, sustaining the outcomes proved to be difficult; hence, the original definition of acuity-adaptable units has not fared well. Variations on the original concept demonstrate that eliminating patient transfers has not been completely abandoned in healthcare redesign and construction initiatives. Terms such as flex-up, flex-down, universal room, and single-stay unit have since emerged. These variations convolute the search for empirical evidence to support the anticipated benefits of the original concept. To determine the future of this concept and its variants, a significant amount of outcome data must be generated by piloting the concept in different hospital settings. As further refinements and adjustments to the concept emerge, the acuity-adaptable room may find a place in future hospitals.

  2. Low-Reynolds Number Effects in Ventilated Rooms

    DEFF Research Database (Denmark)

    Davidson, Lars; Nielsen, Peter V.; Topp, Claus

    In the present study, we use Large Eddy Simulations (LES) which is a suitable method for simulating the flow in ventilated rooms at low Reynolds number.......In the present study, we use Large Eddy Simulations (LES) which is a suitable method for simulating the flow in ventilated rooms at low Reynolds number....

  3. Superação in vitro da dormência de embriões do porta-enxerto de macieira M9 (Malus pumilla Mill. Suppression of in vitro dormancy in embryos of rootstock of apple M9 (Malus pumilla Mill.

    Directory of Open Access Journals (Sweden)

    ADRIANA CIBELE DE MESQUITA DANTAS

    2002-04-01

    Full Text Available A dormência em sementes de macieira é um dos fatores limitantes para o avanço nos programas de melhoramento genético nesta espécie. Assim, o presente estudo objetivou estudar a germinação in vitro de embriões dormentes do porta-enxerto de macieira M9, oriundos da EE São Joaquim da EPAGRI/SC. Os embriões foram excisados de sementes maduras e inoculados em meio basal MS, adicionado de sacarose (30 g.L-1, ágar (6 g.L-1, água de coco (15%, caseína hidrolisada (CH (500 mg.L-1, AIA (0 e 14 µM; AG3 (0 e 1,5 µM, Kin (5 µM, 2-iP (12 µM; BAP (4 µM. As culturas foram mantidas no escuro por 10 dias e transferidas para sala de crescimento sob regime de luz de 16 horas, temperatura de 25 ± 2°C e 40 µmol de radiação luminosa. A maior percentagem de germinação (75% foi obtida em meio MS suplementado com CH (500 mg.L-1, AIA (14 µM, AG3 (1,5 µM e Kin (5 µM. Quando a Kin foi substituída por BAP (4µM, observou-se a formação de calo, sobre o qual se originaram gemas e brotações, cujos valores médios foram de 2,3 brotos por embrião e 12,3 gemas por brotação. Em relação ao comprimento das brotações, não houve diferença significativa entre os tratamentos. A maior percentagem de indução de calos ocorreu em meio de cultura suplementado com AIA, Kin e 2-iP. O meio de cultura MS/2 suplementado com CH e água de coco e isento de fitorreguladores, resultou em 25% de germinação. Já, o número de raízes foi maior no meio de cultura MS suplementado com AIA (14 µM, AG3 (1,5 µM e CH. O comprimento médio das raízes (4,0 cm não foi afetado por nenhum tratamento em particular. Desta forma, esta técnica é uma alternativa eficiente ao uso de tratamentos de frio para a superação da dormência.The embryo dormancy in apple is a limiting factor in breeding programs with this species. Thus the present work was carried out in order to study the in vitro germination of M9 apple dormant embryos, originated from the Experimental

  4. Preliminary considerations on safety of computerized control rooms

    International Nuclear Information System (INIS)

    Vittet, J.

    1983-02-01

    Safety problems are analyzed in this report by the study of the interaction: ''human behavior in a rigid environment/information overload in perturbed situation''. For pedagogy the study is presented as a research of factors influencing operator performance in a control room and a dialogue between an analyst and a conceiving engineer. Danger of all control room where the strategy for data acquisition is too rigid and without spatial reference is stressed in conclusion. Orientations for an advanced control room are outlined [fr

  5. PS Control Room

    CERN Multimedia

    CERN PhotoLab

    1963-01-01

    The good old PS Control Room, all manual. For each parameter, a knob or a button to control it; for each, a light or meter or oscilloscope to monitor it; carefully written pages serve as the data bank; phones and intercom for communication. D.Dekkers is at the microphone, M.Valvini sits in front.

  6. The Patient Safety Attitudes among the Operating Room Personnel

    Directory of Open Access Journals (Sweden)

    Cherdsak Iramaneerat

    2016-07-01

    Full Text Available Background: The first step in cultivating the culture of safety in the operating room is the assessment of safety culture among operating room personnel. Objective: To assess the patient safety culture of operating room personnel at the Department of Surgery, Faculty of Medicine Siriraj Hospital, and compare attitudes among different groups of personnel, and compare them with the international standards. Methods: We conducted a cross-sectional survey of safety attitudes among 396 operating room personnel, using a short form of the Safety Attitudes Questionnaire (SAQ. The SAQ employed 30 items to assess safety culture in six dimensions: teamwork climate, safety climate, stress recognition, perception of hospital management, working conditions, and job satisfaction. The subscore of each dimension was calculated and converted to a scale score with a full score of 100, where higher scores indicated better safety attitudes. Results: The response rate was 66.4%. The overall safety culture score of the operating room personnel was 65.02, higher than an international average (61.80. Operating room personnel at Siriraj Hospital had safety attitudes in teamwork climate, safety climate, and stress recognition lower than the international average, but had safety attitudes in the perception of hospital management, working conditions, and job satisfaction higher than the international average. Conclusion: The safety culture attitudes of operating room personnel at the Department of Surgery, Siriraj Hospital were comparable to international standards. The safety dimensions that Siriraj Hospital operating room should try to improve were teamwork climate, safety climate, and stress recognition.

  7. Improved low frequency room responses by considering finiteness of room boundary surfaces

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2013-01-01

    surface impedance values that are assigned to all the boundary surfaces, the suggested reflection coefficient is found to improve low frequency responses compared to the infinite panel theory; larger improvements are found for a more disproportionate room, more absorptive surfaces, and surfaces having...

  8. Control Room Habitability for Accidental Sulfuric Acid Release

    International Nuclear Information System (INIS)

    Cho, Sungmin; Lee, Heedo; Song, Dongsoo

    2006-01-01

    The 10 CFR 50 Appendix A Criterion 19, 'Control Room', requires that a control room be provided from which actions can be taken to operate the nuclear power unit safely under normal conditions and to maintain it in a safe condition under accident conditions. For compliance with the requirement, the control room of a nuclear power plant should be appropriately protected from hazardous chemicals that may be discharged as a result of equipment failures, operator errors, or events and conditions outside the control of the nuclear power plant. We have excluded sulfuric acid from a target of estimation for control room habitability merely because its boiling point is too high; qualitative analysis in this paper shows that we can exclude sulfuric acid from the target of habitability estimation

  9. Analysis of room transfer function and reverberant signal statistics

    DEFF Research Database (Denmark)

    Georganti, Eleftheria; Mourjopoulos, John; Jacobsen, Finn

    2008-01-01

    For some time now, statistical analysis has been a valuable tool in analyzing room transfer functions (RTFs). This work examines existing statistical time-frequency models and techniques for RTF analysis (e.g., Schroeder's stochastic model and the standard deviation over frequency bands for the RTF...... magnitude and phase). RTF fractional octave smoothing, as with 1-slash 3 octave analysis, may lead to RTF simplifications that can be useful for several audio applications, like room compensation, room modeling, auralisation purposes. The aim of this work is to identify the relationship of optimal response...... and the corresponding ratio of the direct and reverberant signal. In addition, this work examines the statistical quantities for speech and audio signals prior to their reproduction within rooms and when recorded in rooms. Histograms and other statistical distributions are used to compare RTF minima of typical...

  10. The Western Primary School 'Quiet Room' Project.

    Science.gov (United States)

    King, Angus; Chantler, Zara

    2002-01-01

    This article describes a "Quiet Room" project for students with social, emotional, and behavioral problems at a British primary school. The Quiet Room was designed to provide a nurturing environment away from the classroom in which a child's emotional needs can be explored on a one-to-one basis. Benefits for children, parents, and…

  11. Occurrences in control room equipment, procedures and personnel performances: IRS control room events

    International Nuclear Information System (INIS)

    Tolstykh, V.

    1994-01-01

    The IAEA/NEA Incident Reporting System (IRS) was established in the early 1980, its objective being to gain from operating experience achieved in countries with nuclear power programmes by means of exchanging information on events relevant to safety. Among the 2171 events in the database, 175 events (i.e. 8%) were identified as ''control room events''. It was decided to group these into three sets for further study: 65 events with common mode/cause failures (CCFs), 22 events with cognitive errors and 30 events with unforeseen interaction between NPP systems. It is expected that the pitfalls experienced in the IRS and the questions derived from this study will help to gain a better understanding of the needs and interests of specialists in advanced information methods and artificial intelligence in NPP control rooms. (author)

  12. Discussion on control room habitability assessment

    International Nuclear Information System (INIS)

    Li Bing; Chen Yingying; Xiao Jun; Yang Duanjie; Cui Hao

    2014-01-01

    The discussion on control room envelope integrity, source term analysis in habitability assessments and other impact factors for dose consequence is provided combined with regulatory requirements and the current status of domestic NPPs. Considering that the infiltration is an important factor for control room habitability assessment, CRE integrity test should be performed to demonstrate the CRE's infiltration characteristics. The consequence assessment should be performed based on different DBAs and different pathways, such as pathways internal to the plant. (authors)

  13. From Smart Rooms to Smart Hotels

    OpenAIRE

    Petrevska, Biljana; Cingoski, Vlatko; Gelev, Saso

    2016-01-01

    This paper gives an overview of a potential path that new hotels have to satisfy to improve their status from a hotel with smart rooms towards a full-scale smart hotel facility. It presents a possible transitional way including innovative applications based on modern information technology for ambient settings in the domain of hotel industry that aims to improve the quality of offered services towards clients, starting from the present level of smart rooms. The main objective i...

  14. Diversity of anaerobic microbes in spacecraft assembly clean rooms.

    Science.gov (United States)

    Probst, Alexander; Vaishampayan, Parag; Osman, Shariff; Moissl-Eichinger, Christine; Andersen, Gary L; Venkateswaran, Kasthuri

    2010-05-01

    Although the cultivable and noncultivable microbial diversity of spacecraft assembly clean rooms has been previously documented using conventional and state-of-the-art molecular techniques, the occurrence of obligate anaerobes within these clean rooms is still uncertain. Therefore, anaerobic bacterial communities of three clean-room facilities were analyzed during assembly of the Mars Science Laboratory rover. Anaerobic bacteria were cultured on several media, and DNA was extracted from suitable anaerobic enrichments and examined with conventional 16S rRNA gene clone library, as well as high-density phylogenetic 16S rRNA gene microarray (PhyloChip) technologies. The culture-dependent analyses predominantly showed the presence of clostridial and propionibacterial strains. The 16S rRNA gene sequences retrieved from clone libraries revealed distinct microbial populations associated with each clean-room facility, clustered exclusively within gram-positive organisms. PhyloChip analysis detected a greater microbial diversity, spanning many phyla of bacteria, and provided a deeper insight into the microbial community structure of the clean-room facilities. This study presents an integrated approach for assessing the anaerobic microbial population within clean-room facilities, using both molecular and cultivation-based analyses. The results reveal that highly diverse anaerobic bacterial populations persist in the clean rooms even after the imposition of rigorous maintenance programs and will pose a challenge to planetary protection implementation activities.

  15. Room Airflows with Low Reynolds Number Effects

    DEFF Research Database (Denmark)

    Topp, Claus; Nielsen, Peter V.; Davidson, Lars

    The behaviour of room airflows under fully turbulent conditions is well known both in terms of experiments and, numerical calculations by computational fluid dynamics (CFD). For room airflows where turbulence is not fully developed though, i.e. flows at low Reynolds numbers, the existing knowledge...... is limited. It has been the objective to investigate the behaviour of a plane isothermal wall jet in a full-scale ventilated room at low Reynolds numbers, i.e. when the flow is not fully turbulent. The results are significantly different from known theory for fully turbulent flows. It was found that the jet...... constants are a strong function of the Reynolds number up to a level of Reh≈500....

  16. Engineering Process Monitoring for Control Room Operation

    CERN Document Server

    Bätz, M

    2001-01-01

    A major challenge in process operation is to reduce costs and increase system efficiency whereas the complexity of automated process engineering, control and monitoring systems increases continuously. To cope with this challenge the design, implementation and operation of process monitoring systems for control room operation have to be treated as an ensemble. This is only possible if the engineering of the monitoring information is focused on the production objective and is lead in close collaboration of control room teams, exploitation personnel and process specialists. In this paper some principles for the engineering of monitoring information for control room operation are developed at the example of the exploitation of a particle accelerator at the European Laboratory for Nuclear Research (CERN).

  17. STANDAR OPERASIONAL PROSEDUR ROOM SERVICE AMAROOSSA HOTEL BANDUNG

    OpenAIRE

    Panji Septian Derianto; Yuliana Pinaringsih Kristiutami

    2016-01-01

    Abstract - Tourism is everything that is related to and associated with the business needs someone to travel. And each traveler typically require service facilities to rest and service for food and beverages. Every hotel both large and small certainly has a restaurant and bar on the ground guests can enjoy food and drinks, while for guests who wish to enjoy food and drink in your own room is also equipped with service facilities room service. Room service department operates for 24 hours to s...

  18. Advanced control room caters for the operator

    International Nuclear Information System (INIS)

    George, C.R.; Rygg, D.E.

    1980-01-01

    In existing control rooms the operators' efficiency is often limited by widely scattered and sometimes illogically arranged controls which tend to increase the potential for outages or equipment damage. The advanced control room described allows instant and ready access to preselected information and control by one or two operators from a seated or standing position. (author)

  19. Parametric Room Acoustic Workflows

    DEFF Research Database (Denmark)

    Parigi, Dario; Svidt, Kjeld; Molin, Erik

    2017-01-01

    The paper investigates and assesses different room acoustics software and the opportunities they offer to engage in parametric acoustics workflow and to influence architectural designs. The first step consists in the testing and benchmarking of different tools on the basis of accuracy, speed...... and interoperability with Grasshopper 3d. The focus will be placed to the benchmarking of three different acoustic analysis tools based on raytracing. To compare the accuracy and speed of the acoustic evaluation across different tools, a homogeneous set of acoustic parameters is chosen. The room acoustics parameters...... included in the set are reverberation time (EDT, RT30), clarity (C50), loudness (G), and definition (D50). Scenarios are discussed for determining at different design stages the most suitable acoustic tool. Those scenarios are characterized, by the use of less accurate but fast evaluation tools to be used...

  20. Clinical Education Environment Experiences of Operating Room Students

    Directory of Open Access Journals (Sweden)

    Tahereh khazaei

    2016-01-01

    Full Text Available Background and purpose: The objective of medical education is to train competent and qualified workforce in order to provide services in various health environments. One of the important objectives of Operating Room students is to train workforce who can involve in patient’s health and recovery. Training these students should cause clinical ability and independent decision making during surgery. Since students during internship face with many problems, this study has been conducted to explore and describe the challenges and experiences.Methods: This qualitative study is a phenomenology that was conducted based on 20 students in the last semester of Operating Room associate’s degree with purposive sampling. Deep and semi-structured interviews were used to collect data and data were analyzed by content analysis method.Results: The findings in 5 main themes: (1 Physical space and equipment in the operating room, (2 The student’s position in operating room, (3 Integrating knowledge and action, (4 Managing education environment and 5- Student’s viewpoint about operating room and working in it.Conclusions: Interviews with students revealed the educational environment challenges with which they are faced during their study. Teachers can provide solutions to overcome the challenges and create a positive atmosphere for students' learning using results of this study and students may continue their interest in education and improve the quality of their education.Keywords: CLINICAL EDUCATION, OPERATING ROOM STUDENTS, CHALLENGE

  1. Study on the main control room design for Hamaoka Unit No.5

    International Nuclear Information System (INIS)

    Tsuruta, Tadakazu; Sakamoto, Minoru; Maruyama, Tohru; Saito, Tadashi

    2000-01-01

    The main control room of nuclear power station is important to operate the power station and to promote public acceptance of nuclear power station. To enhance them, there is an idea of high ceiling control room with a gallery room located in backside middle upper floor. The control room is expected to enhance habitability and to offer visitors the fine view of the control room. In this study, psychological and physiological influence of such a high ceiling control room design on operators was investigated first. And then some human engineering requirements for desirable main control room were identified. A control room (ceiling height: about 5 meters) adequate to the requirements was designed, and finally the validity of the design was verified by means of full mockup model room tests. The results of this study are applied to the main control room design of Hamaoka Nuclear Power Station Unit No.5 (Chubu Electric Power Co., Inc.) (author)

  2. Controlling allergens in animal rooms by using curtains

    DEFF Research Database (Denmark)

    Krohn, Thomas Cæcius; Itter, Gabi; Fosse, Richard

    2006-01-01

    The reduction and control of allergens in the animal facility is important for staff working with laboratory animals. This study was designed to evaluate the efficiency of perforated Makrolon curtains in front of racks as a method to reduce the amount of allergen in the animal room. The experimen......The reduction and control of allergens in the animal facility is important for staff working with laboratory animals. This study was designed to evaluate the efficiency of perforated Makrolon curtains in front of racks as a method to reduce the amount of allergen in the animal room....... The experimental situation we studied provides some information regarding allergen disposition in animal rooms but is clearly artificial and does not reflect a typical, ‘real-world’ environment in terms of preventing exposure of workers to allergens. Plastic curtains with holes were placed in front of racks......, and a corridor between the racks and a curtain was present. The room was ventilated with air, which was blown into the room through the middle of the corridor, flowing downstream and passing through the holes in the curtain. This set-up resulted in air flow from the corridor through the curtain. Air samples were...

  3. Computer code for shielding calculations of x-rays rooms

    International Nuclear Information System (INIS)

    Affonso, R.R.W.; Borges, D. da S.; Lava, D.D.; Moreira, M. de L.; Guimarães, A.C.F.

    2015-01-01

    The building an effective barrier against ionizing radiation present in radiographic rooms requires consideration of many variables. The methodology used for thickness specification of primary and secondary, barrier of a traditional radiographic room, considers the following factors: Use Factor, Occupational Factor, distance between the source and the wall, Workload, Kerma in the air and distance between the patient and the source. With these data it was possible to develop a computer code, which aims to identify and use variables in functions obtained through graphics regressions provided by NCRP-147 (Structural Shielding Design for Medical X-Ray Imaging Facilities) report, for shielding calculation of room walls, and the walls of the dark room and adjacent areas. With the implemented methodology, it was made a code validation by comparison of results with a study case provided by the report. The obtained values for thickness comprise different materials such as concrete, lead and glass. After validation it was made a case study of an arbitrary radiographic room.The development of the code resulted in a user-friendly tool for planning radiographic rooms to comply with the limits established by CNEN-NN-3:01 published in september/2011. (authors)

  4. Computational model of gamma irradiation room at ININ

    Science.gov (United States)

    Rodríguez-Romo, Suemi; Patlan-Cardoso, Fernando; Ibáñez-Orozco, Oscar; Vergara Martínez, Francisco Javier

    2018-03-01

    In this paper, we present a model of the gamma irradiation room at the National Institute of Nuclear Research (ININ is its acronym in Spanish) in Mexico to improve the use of physics in dosimetry for human protection. We deal with air-filled ionization chambers and scientific computing made in house and framed in both the GEANT4 scheme and our analytical approach to characterize the irradiation room. This room is the only secondary dosimetry facility in Mexico. Our aim is to optimize its experimental designs, facilities, and industrial applications of physical radiation. The computational results provided by our model are supported by all the known experimental data regarding the performance of the ININ gamma irradiation room and allow us to predict the values of the main variables related to this fully enclosed space to within an acceptable margin of error.

  5. [Operating Room Nurses' Experiences of Securing for Patient Safety].

    Science.gov (United States)

    Park, Kwang Ok; Kim, Jong Kyung; Kim, Myoung Sook

    2015-10-01

    This study was done to evaluate the experience of securing patient safety in hospital operating rooms. Experiential data were collected from 15 operating room nurses through in-depth interviews. The main question was "Could you describe your experience with patient safety in the operating room?". Qualitative data from the field and transcribed notes were analyzed using Strauss and Corbin's grounded theory methodology. The core category of experience with patient safety in the operating room was 'trying to maintain principles of patient safety during high-risk surgical procedures'. The participants used two interactional strategies: 'attempt continuous improvement', 'immersion in operation with sharing issues of patient safety'. The results indicate that the important factors for ensuring the safety of patients in the operating room are manpower, education, and a system for patient safety. Successful and safe surgery requires communication, teamwork and recognition of the importance of patient safety by the surgical team.

  6. Working conditions of a radiodiagnostic room

    International Nuclear Information System (INIS)

    Chikirdin, Eh.G.

    1983-01-01

    The concept of ''operating load'' of an X-ray diagnostic room is explained. The concept includes the calculation of the Week's maximum exposure calculation and monitoring of stationary radiation shielding, measurements of exposure dose rate at working places. In this case the substitution of the actual repeated short-time regime of emitter operation for the calculated continuous regime is performed. The data on the ''operating load'' of X-ray diagnostic room are presented taking into account the method of X-ray investigation

  7. The operating room of the future: observations and commentary.

    Science.gov (United States)

    Satava, Richard M

    2003-09-01

    The Operating Room of the Future is a construct upon which to develop the next generation of operating environments for the patient, surgeon, and operating team. Analysis of the suite of visions for the Operating Room of the Future reveals a broad set of goals, with a clear overall solution to create a safe environment for high-quality healthcare. The vision, although planned for the future, is based upon iteratively improving and integrating current systems, both technology and process. This must become the Operating Room of Today, which will require the enormous efforts described. An alternative future of the operating room, based upon emergence of disruptive technologies, is also presented.

  8. Taking account of human factors in control-room design

    International Nuclear Information System (INIS)

    Dien, Y.; Montmayeul, R.

    1995-07-01

    Since the Three Mile Island accident two ways for improving the Human-Machine Interface have mainly been followed: the development of computerized operator aids in existing control-rooms and the design of advanced control-rooms. Insufficient attention paid to human factors in the design of operator aids has generally led to these aids being neglected or unused by their potential users. While for the design of advanced control-rooms efforts have been made for dealing with human factors in more extensive way. Based upon this experience, a general method for taking account of human factors in a control-room design has been devised and is described in this paper. (author)

  9. Workplace culture among operating room nurses.

    Science.gov (United States)

    Eskola, Suvi; Roos, Mervi; McCormack, Brendan; Slater, Paul; Hahtela, Nina; Suominen, Tarja

    2016-09-01

    To investigate the workplace culture in the Operating Room (OR) environment and the factors associated with it. In health care, the workplace culture affects the delivery and experience of care. The OR can be a stressful practice environment, where nurses might have occasionally either job stress or job satisfaction based on their competence. A quantitative cross-sectional approach was used. The study consisted of 96 Finnish OR nurses. A Nursing Context Index instrument was used to obtain data by way of an electronic questionnaire. The primary role and working unit of respondents were the main components relating to workplace culture, and especially to job stress. Nurse anaesthetists were found to be slightly more stressed than scrub nurses. In local hospitals, job stress related to workload was perceived less than in university hospitals (P = 0.001). In addition, OR nurses in local hospitals were more satisfied with their profession (P = 0.007), particularly around issues concerning adequate staffing and resources (P = 0.001). It is essential that nurse managers learn to recognise the different expressions of workplace culture. In particular, this study raises a need to recognise the factors that cause job stress to nurse anaesthetists. © 2016 John Wiley & Sons Ltd.

  10. 76 FR 35130 - Pipeline Safety: Control Room Management/Human Factors

    Science.gov (United States)

    2011-06-16

    ...: Control Room Management/Human Factors AGENCY: Pipeline and Hazardous Materials Safety Administration... the Control Room Management/Human Factors regulations in order to realize the safety benefits sooner... FR 5536). By this amendment to the Control Room Management/Human Factors (CRM) rule, an operator must...

  11. Creys-Malville control room and data processing

    International Nuclear Information System (INIS)

    Decuyper, J.

    1984-01-01

    After a brief definition of the control of a plant, this article presents the Creys-Malville control room: control means display and considerations on ergonomy and specific features in respect of the PWR control room. The Creys-Malville data processing is then rapidly presented with a brief description, the different data treatments and the specificity of the centralised data computer [fr

  12. Interdisciplinary New University: A New Model for Faculties of Arts and Sciences in Turkey

    Science.gov (United States)

    Simsek, Hasan; Hacifazlioglu, Ozge

    2012-01-01

    The concept of new university reduces the depth of disciplinary understanding at the undergraduate level. Instead, interdisciplinary understanding has been put forward, where room is provided for the broader development of student. Receiving training from multiple perspectives will provide students with the skills necessary in an era of present…

  13. Experimental and numerical comparison of absorption optimization in small rooms

    DEFF Research Database (Denmark)

    Wincentz, Jakob Nygård; Garcia, Julian Martinez-Villalba; Jeong, Cheol-Ho

    2016-01-01

    the Schroeder frequency. This project investigates experimentally changes in the room acoustic parameters by altering the positioning and orientation of porous materials in a small room, which are compared with finite element method (FEM) simulations. FEM is able to take into account the exact room geometry......, boundary conditions, and phase information providing accuracy at low frequencies. Good agreements are found between measurements and simulations, confirming that FEM can be used as a design tool for optimizing absorption and acoustic parameters in small rooms...

  14. Influence of Diffusivity in Room on its Acoustic Response

    Directory of Open Access Journals (Sweden)

    D. Šumarac Pavlović

    2010-11-01

    Full Text Available Diffusivity is a geometrical feature of the room which is proportional to the dimension of relief on its interior surfaces. This paper presents the results of analysis which investigates the correlation between diffusivity in a room and parameters calculated from a recorded impulse response. The analysis was performed using a specially prepared physical model of a parallelepipedic room with different combinations of flat and diffusive interior surfaces.

  15. Novel room temperature ferromagnetic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Amita [KTH Royal Inst. of Technology, Stockholm (Sweden)

    2004-06-01

    Today's information world, bits of data are processed by semiconductor chips, and stored in the magnetic disk drives. But tomorrow's information technology may see magnetism (spin) and semiconductivity (charge) combined in one 'spintronic' device that exploits both charge and 'spin' to carry data (the best of two worlds). Spintronic devices such as spin valve transistors, spin light emitting diodes, non-volatile memory, logic devices, optical isolators and ultra-fast optical switches are some of the areas of interest for introducing the ferromagnetic properties at room temperature in a semiconductor to make it multifunctional. The potential advantages of such spintronic devices will be higher speed, greater efficiency, and better stability at a reduced power consumption. This Thesis contains two main topics: In-depth understanding of magnetism in Mn doped ZnO, and our search and identification of at least six new above room temperature ferromagnetic semiconductors. Both complex doped ZnO based new materials, as well as a number of nonoxides like phosphides, and sulfides suitably doped with Mn or Cu are shown to give rise to ferromagnetism above room temperature. Some of the highlights of this work are discovery of room temperature ferromagnetism in: (1) ZnO:Mn (paper in Nature Materials, Oct issue, 2003); (2) ZnO doped with Cu (containing no magnetic elements in it); (3) GaP doped with Cu (again containing no magnetic elements in it); (4) Enhancement of Magnetization by Cu co-doping in ZnO:Mn; (5) CdS doped with Mn, and a few others not reported in this thesis. We discuss in detail the first observation of ferromagnetism above room temperature in the form of powder, bulk pellets, in 2-3 mu-m thick transparent pulsed laser deposited films of the Mn (<4 at. percent) doped ZnO. High-resolution transmission electron microscopy (HRTEM) and electron energy loss spectroscopy (EELS) spectra recorded from 2 to 200nm areas showed homogeneous

  16. Challenges and solutions for realistic room simulation

    Science.gov (United States)

    Begault, Durand R.

    2002-05-01

    Virtual room acoustic simulation (auralization) techniques have traditionally focused on answering questions related to speech intelligibility or musical quality, typically in large volumetric spaces. More recently, auralization techniques have been found to be important for the externalization of headphone-reproduced virtual acoustic images. Although externalization can be accomplished using a minimal simulation, data indicate that realistic auralizations need to be responsive to head motion cues for accurate localization. Computational demands increase when providing for the simulation of coupled spaces, small rooms lacking meaningful reverberant decays, or reflective surfaces in outdoor environments. Auditory threshold data for both early reflections and late reverberant energy levels indicate that much of the information captured in acoustical measurements is inaudible, minimizing the intensive computational requirements of real-time auralization systems. Results are presented for early reflection thresholds as a function of azimuth angle, arrival time, and sound-source type, and reverberation thresholds as a function of reverberation time and level within 250-Hz-2-kHz octave bands. Good agreement is found between data obtained in virtual room simulations and those obtained in real rooms, allowing a strategy for minimizing computational requirements of real-time auralization systems.

  17. Presentation and analysis of work at the emergency department – of the University children’s Hospital Ljubljana

    Directory of Open Access Journals (Sweden)

    Tina Bregant

    2013-05-01

    Conclusions: Since 2010, the paediatric emergency department of the University Children’s Hospital Ljubljana has functioned in compliance wtih the guidelines used in similar international tertiary centres. However, there is still room for improvement in organization and staffing.

  18. Room-temperature ductile inorganic semiconductor

    Science.gov (United States)

    Shi, Xun; Chen, Hongyi; Hao, Feng; Liu, Ruiheng; Wang, Tuo; Qiu, Pengfei; Burkhardt, Ulrich; Grin, Yuri; Chen, Lidong

    2018-05-01

    Ductility is common in metals and metal-based alloys, but is rarely observed in inorganic semiconductors and ceramic insulators. In particular, room-temperature ductile inorganic semiconductors were not known until now. Here, we report an inorganic α-Ag2S semiconductor that exhibits extraordinary metal-like ductility with high plastic deformation strains at room temperature. Analysis of the chemical bonding reveals systems of planes with relatively weak atomic interactions in the crystal structure. In combination with irregularly distributed silver-silver and sulfur-silver bonds due to the silver diffusion, they suppress the cleavage of the material, and thus result in unprecedented ductility. This work opens up the possibility of searching for ductile inorganic semiconductors/ceramics for flexible electronic devices.

  19. Superação da dormência de sementes de carrapicho-beiço-de-boi Dormancy overcoming in Desmodium tortuosum seeds

    Directory of Open Access Journals (Sweden)

    Cibele C. Martins

    1997-01-01

    Full Text Available Visando a obtenção de um tratamento para acelerar a germinação de sementes de Desmodium tortuosum (Sw. DC., foram realizados dois experimentos, nos quais, segmentos unisseminados de lomentos (testemunha foram submetidos a debulha manual; debulha manual seguida por escarificação manual empregando-se lixa n. 220; debulha mecânica (processador doméstico ; escarificação química com H2SO4 (95% por 1,5 e 8 mim pré-aquecimento à 53°C por 4,10 e 16h em estufa com circulação forçada de ar; embebição, utilizando-se H,0 à 80°C por 1,3,5 e 10 min; H20 à 27°C por 2h e embebição com alternância térmica (H,0 à 80°C/ 5min e H20 à 13 °C / 1min . Para a avaliação dos tratamentos foram empregados os testes de germinação, de emergência de plântulas em solo (E, de primeira contagem de germinação (PG e de emergência (PE, índices de velocidade de germinação (I.V.G. e de emergência (I.V.E., e o comprimento de plântulas (CP. 0 delineamento estatístico adotado foi o inteiramente casualizado com 4 repetições de 100 (G, PG, I.V.G. ou 20 sementes (C P por tratamento no primeiro experimento e 4 repetições de 50 (G, PG, I.V.G. ou 100 sementes (E, PE, I.V.E. no segundo experimento. No primeiro experimento, os tratamentos que provocaram significativa redução da dormência (D e, conseqüente elevação da germinação (G, em comparação à testemunha (D=82%; G=15% foram, em ordem decrescente de eficácia: debulha e escarificação manuais (D=3%; G= 92%, debu lha mecânica (D=13%; G= 81%, embebição em H20 à 80°C por 1min (D=68%; G= 29% e por 3 min (D=65%; G=32%. No segundo experimento, (testemunha com D=93% e G=3% destacaram-se: debulha e escarificação manuais (D=2%; G= 93%, debulha mecânica (D = 2%; G = 87%, embebição em H20 à 80°C por 5min e alternância térmica (ambos com D=85% e G= 11%. 0s testes de vigor PC, I.V. G., I.V. E., CP, e E corroboraram esses resultados. 0s métodos de escarificação manual com lixa

  20. The Czech Tea Profession and the Phenomenon of Tea Rooms

    OpenAIRE

    Schröderová, Karolína

    2015-01-01

    In this bachelor thesis I have focused on the Czech tea culture and tea profession across tea rooms. I have dealt with influences that led to the present tea rooms' appearances. Furthermore I am dealing with ways of tea culture spreading, and what conduces to the tea room establishing. I am using the term of subculture in the connection with the tea culture, its meaning and position in the Czech culture. The main data source were semi- structured interviews with the tea rooms owners, all comp...

  1. University building safety index measurement using risk and implementation matrix

    Science.gov (United States)

    Rahman, A.; Arumsari, F.; Maryani, A.

    2018-04-01

    Many high rise building constructed in several universities in Indonesia. The high-rise building management must provide the safety planning and proper safety equipment in each part of the building. Unfortunately, most of the university in Indonesia have not been applying safety policy yet and less awareness on treating safety facilities. Several fire accidents in university showed that some significant risk should be managed by the building management. This research developed a framework for measuring the high rise building safety index in university The framework is not only assessed the risk magnitude but also designed modular building safety checklist for measuring the safety implementation level. The safety checklist has been developed for 8 types of the university rooms, i.e.: office, classroom, 4 type of laboratories, canteen, and library. University building safety index determined using risk-implementation matrix by measuring the risk magnitude and assessing the safety implementation level. Building Safety Index measurement has been applied in 4 high rise buildings in ITS Campus. The building assessment showed that the rectorate building in secure condition and chemical department building in beware condition. While the library and administration center building was in less secure condition.

  2. A new remote control room for tokamak operations

    Energy Technology Data Exchange (ETDEWEB)

    Schissel, D.P., E-mail: schissel@fusion.gat.com [General Atomics, P.O. Box 85608, San Diego, CA (United States); Abla, G.; Flanagan, S.; Kim, E.N. [General Atomics, P.O. Box 85608, San Diego, CA (United States)

    2012-12-15

    This paper presents a summary of a new remote tokamak control room constructed near the offices of DIII-D's scientific staff. This integrated system combines hardware, software, data, and control of the room (R-232) into a unified package that has been designed and constructed in a generic fashion so that it can be used with any tokamak operating worldwide. The room is approximately 300 ft{sup 2} and can accommodate up to 12 seated participants. Mounted on the wall facing each scientist are five 52 Double-Prime LCD televisions and mounted to the wall on their right are six 24 Double-Prime LCD monitors. Each seat has associated with it a 24 Double-Prime monitor, network connection, and power and the scientist is either provided with a computer or they can use their own. The room has been used for operation of DIII-D, EAST, and KSTAR. Due to the long distances, data from EAST and KSTAR was brought back to local DIII-D computers in one large parallel network transfer and subsequently served to scientists in the remote control room to other US collaborators. This parallel data transfer allowed the data to be available to US participants between pulses making remote experimental participation highly effective.

  3. ATP bioluminescence: Surface hygiene monitoring in milk preparation room of neonatal intensive care unit

    Science.gov (United States)

    Mohamad, Mahirah; Ishak, Shareena; Jaafar, Rohana; Sani, Norrakiah Abdullah

    2018-04-01

    ATP Bioluminescence application and standard microbiological analyses were used to evaluate the cleanliness of milk contact surfaces and non-milk contact surfaces in milk preparation room of neonatal intensive care unit (NICU) of Universiti Kebangsaan Malaysia Medical Centre (UKMMC). A total of 44 samples including the breast pump, milk bottle, milk bottle screw top and screw ring, teats, measuring cups, waterless warmer, refrigerator, dishwasher and pasteurizer inner wall were tested on May 2017. 3M Clean and Trace Hygiene Monitoring (UXL100 ATP Test swabs) and the bioluminescence reader Clean-Trace NG Luminometer (3M) were used to measure the Relative Light Unit (RLU) and microbiological analysis using 3M Quick Swab and 3MTM PetrifilmTM for enumeration of aerobic count, Staphylococcus aureus, Enterobacteriaceae, coliform and detection of Escherichia coli (CFU /100cm2 or utensil/item). The RLU values were from 11 to 194 and passed the ATP benchmark for intensive care unit (ICU), < 250 RLU as recommended. Aerobic colony count was only found in waterless warmer (0.05±0.01 mean log CFU/warmer). None of S. aureus, Enterobacteriaceae, E. coli and coliform was detected in all samples. A weak correlation was found between bioluminescence measurements RLU and the microbiological analysis (CFU). However, the use of ATP bioluminescence in monitoring milk preparation room cleanliness can be a useful method for assessing rapidly the surface hygiene as well as to verify the Sanitation Standard Operating Procedure (SSOP) prior to implementation of Hazard Analysis and Critical Control Points (HACCP) in milk preparation room.

  4. Considerations concerning the ergonomics of power plant control rooms

    International Nuclear Information System (INIS)

    Herbst, L.; Hinz, W.

    1981-01-01

    Modern control rooms for the monitoring and control of large power plants have a high degree of automation. However, it is the responsibility of the control room personnel to ensure optimum process control during all operational states. The proper ergonomic design of a control room is one of the prerequisites to ensure that the operators are able to perceive the often large flow of current information and, after processing, to respond properly. (orig.) [de

  5. Decontamination of the chemical crane room and decontamination and decommissioning of the extraction chemical room at the West Valley Demonstration Project

    International Nuclear Information System (INIS)

    Phillips, E.C.; Golden, M.P.

    1986-01-01

    This paper describes the decontamination of the Chemical Crane Room (CCR) of the West Valley Plant and the Extraction Chemical Room (XCR) from radioactively contaminated conditions to essentially shirt sleeve environments. In both cases, subsequent use re-contaminated the rooms. Prior to decontamination, general exposure rates in the CCR were 50 to 100 mR/hr with hot spots as high as 2000 mR/hr. Smearable levels on the floor were in the range of 10 5 to 10 6 dpm per 100/cm 2 . Respiratory protection was mandatory for entry. In the Extraction Chemical Room (XCR) prior to decontamination and decommissioning (D/D), radiological surveys indicated a maximum radiation field of 5 mR/hr, due to sources internal to the room, and 20,000 dpm beta/100 cm 2 surface contamination. A radiation source external to the XCR caused a hot spot with a 9 mR/hr exposure rate inside the XCR. The CCR, located at the north end of the Chemical Process Cell (CPC) is for the storage and servicing of two bridge cranes used in the CPC. Decontamination and exposure reduction in the CCR has been completed using vacuum cleaning, damp wipe down, and surface grinding followed by shielding and painting. The decontamination and decommissioning of the Extraction Chemical Room (XCR), located on the fifth floor elevation (160') of the reprocessing plant at the WVDP, has been completed. D/D operations included removal of piping, tanks, supports, and equipment to provide a clean work area of about 3000 square feet and 17 feet high

  6. Building for changing-rooms, laundry, laboratories

    International Nuclear Information System (INIS)

    Nemeth, L.; Mezes, J.; Gulyas, F.; Hejj, A.; Matyas, J.

    1979-01-01

    This building accomodates important service sections of the power plant. The changing-rooms of the primary circuit are here, through which the employees, under the supervision of health physics service, pass to the radioactive contaminated jobs. Working-clothes are cleaned in laundries located on the ground-floor. The building houses the health measurement control rooms of the four reactor sets and the control centre of the power plant. The laboratories dealing with process control, electrical engineering, radiology, dosimetry, material tests and reactor physics will be located here. (author)

  7. Calculation of Vertical Temperature Gradients in Heated Rooms

    DEFF Research Database (Denmark)

    Overby, H.; Steen-Thøde, Mogens

    This paper deals with a simple model which predicts the vertical temperature gradient in a heated room. The gradient is calculated from a dimensionless temperature profile which is determined by two room air temperatures only, the mean temperature in the occupied zone and the mean temperature...

  8. Assessing ventilation system performance in isolation rooms

    Energy Technology Data Exchange (ETDEWEB)

    Balocco, Carla [Department of Energy Engineering ' ' Sergio Stecco' ' , via S. Marta 3, Firenze (Italy); Lio, Pietro [Computer Laboratory, University of Cambridge, 15 JJ Thompson Avenue, CB03FD Cambridge (United Kingdom)

    2011-01-15

    In this paper numerical transient simulations were used to investigate the air flow patterns, distribution and velocity, and the particulate dispersion inside an existing typical hospitalization room equipped with an advanced Heating Ventilation Air Conditioning (HVAC), with Variable Air Volume (VAV) primary air system designed for immune-suppressed patients never modelled before. The three-dimensional models of the room consider different, most typical, positions of the patients. Results indicate the best conditions for the high induction air inlet diffuser and the scheme of pressures imposed in the room to provide the effective means of controlling flows containing virus droplets. We believe that our work exemplifies the usefulness of numerical investigations of HVAC performances in real situations and provides important recommendations towards disease control and careful design and optimization of ventilation in hospital settings. (author)

  9. I'm dreaming of a white clean room...

    CERN Multimedia

    Katarina Anthony

    2014-01-01

    New HIE-ISOLDE cryomodules are now under construction in a state-of-the-art clean room facility in SM18.   The HIE-ISOLDE clean rooms in SM18. HIE-ISOLDE is set to be the world's leading nuclear physics site, ultimately accelerating radioactive nuclei to an impressive 10 MeV/u. Helping the facility reach this energy are new superconducting cryomodules, the first quarter-wave cavity module to be assembled at CERN and necessitating a custom clean-room in SM18. At a towering five metres tall, the new clean room houses a custom assembly frame and associated equipment, moving the components of the 6 tonne cryomodules both vertically and horizontally while they are being assembled. "Each cryomodule is made up of some 10,000 parts, which have come from across the continents to be assembled here," says CERN TE engineer Lloyd Williams, who is managing quality assurance for the project. "Each part is checked by the CERN team, catalogued and thoroughly cleaned, befor...

  10. Use of task analysis in control room evaluations

    International Nuclear Information System (INIS)

    Ross, K.C.

    1981-01-01

    Responding to recently formulated regulatory requirements, the BWR Owners' Group, working in conjunction with General Electric, has formulated a method for performing human factors design reviews of nuclear power plant control rooms. This process incorporates task analyses to analyze operational aspects of panel layout and design. Correlation of operator functions defined by emergency procedures against required controls and displays has proven successful in identifying instrumentation required in the control room to adequately respond to transient conditions, and in evaluating the effectiveness of panel design and physical arrangement. Extensions of the analysis have provided information on operator response paths, frequency of use of instruments, and control room layout. The techniques used were based on a need to identify primary controls and indications required by the operator in performing each step of the applicable procedure. The relative locations of these instruments were then analyzed for information on the adequacy of the control room design for those conditions

  11. Design of a multisystem remote maintenance control room

    International Nuclear Information System (INIS)

    Draper, J.V.; Handel, S.J.; Kring, C.T.; Kawatsuma, S.

    1988-01-01

    The Remote Systems Development Section of the Consolidated Fuel Reprocessing Program at the Oak Ridge National Laboratory (ORNL) and Japan's Power Reactor and Nuclear Fuel Development Corporation (PNC) recently collaborated in the development of a control room concept for remote operations. This report describes design methods and the resulting control room concept. The design project included five stages. The first was compilation of a complete function list; functions are tasks performed by operators in the control room while operating equipment located in the remote area. The second step was organization of the function list into ''function groups;'' function groups are sets of functions that operate one piece of equipment. The third stage was determination of crew size and requirements for supervision. The fourth stage was development of conceptual designs of displays and controls. The fifth stage was development of plans for placement of crew stations within the control room. 5 figs., 1 tab

  12. 75 FR 69912 - Pipeline Safety: Control Room Management/Human Factors

    Science.gov (United States)

    2010-11-16

    ... 192 and 195 [Docket ID PHMSA-2007-27954] RIN 2137-AE64 Pipeline Safety: Control Room Management/Human... Control Room Management/Human Factors rule at 49 CFR 192.631 and 195.446. The NPRM proposes to expedite... rule and to engage in open discussions with the agency at PHMSA's Control Room Management...

  13. Criteria of choosing building structures for rooftop boiler rooms

    Directory of Open Access Journals (Sweden)

    Plotnikov Artyom

    2018-01-01

    Full Text Available The paper investigates parameters of noise and vibration distribution in the territory of residential area depending on the structural materials and power of independent heat supply systems. Rooftop boiler rooms are decentralized heat supply systems in buildings. Today, residential areas are strongly affected by noise and vibrations. Adverse effects are isolated by buildings materials, protective shields and floating floors. Rooftop boiler rooms located in Tyumen city were investigated within this research. Structures of rooftop boiler rooms were analyzed. Acoustic analysis results and the parameters of equivalent continuous sound level are presented. An option for improvement of rooftop boiler rooms structures is suggested. Comparison of capital investments in construction and installation activities is carried out. Conclusion on capital investments required for noise protection is made.

  14. Experimental and numerical comparison of absorption optimization in small rooms

    DEFF Research Database (Denmark)

    Wincentz, Jakob Nygård; Garcia, Julian Martinez-Villalba; Jeong, Cheol-Ho

    2016-01-01

    A vast majority of modern music is recorded and produced in small control room environments of volumes of around 50 m3 . Several problems occur when controlling the room acoustics of such small spaces. First, the room modes will produce strong peaks and dips particularly at lower frequencies......, and even in the sweet spot position the listening experience can be easily deteriorated. Second, when designing or refurbishing small rooms it is hard to adequately predict the reverberation time by using Sabine’s formula due to highly non-diffuse conditions and using a statistical approach below......, boundary conditions, and phase information providing accuracy at low frequencies. Good agreements are found between measurements and simulations, confirming that FEM can be used as a design tool for optimizing absorption and acoustic parameters in small rooms...

  15. Improving student satisfaction of Andalas University Dormitory through Service Quality and Importance Performance Analysis

    Science.gov (United States)

    Putri, Nilda Tri; Anggraini, Larisa

    2018-03-01

    Residential satisfaction of university dormitories serve as one of the significant aspects in the framework of sustainability in higher education. This research investigated the quality of dormitory services in Andalas University Dormitory based on student’s satisfaction. According to management residential, the enrollment of residential student has increased gradually in Andalas University. In 2016, capacity of residential student is 1686, but only 1081 students can stay at dormitory because some rooms in bad condition. There are a lot of problems and complaints regarding dormitory’s service quality i.e water problems, leaky rooms and bathrooms, cleanliness and inadequate facilities in residential college. In addition, there are 20% of last year student’s residential check out before the time of contract runs out. The aim of this research are understanding the level of GAP exists between expectation and perception students’ residential in the content of service quality and evaluating the improvement priority services using Importance Performance Analysis. This study is measuring service quality by using Responsiveness, Assurance, Empathy, Reliability and Tangible dimension. A negative GAP indicates that the actual services are than what was expected and the GAP is highlighted area for improvement. Based on IPA, management should improve this following dimension services : responsiveness, tangible and assurance dimension.

  16. Control rooms in German nuclear power plants

    International Nuclear Information System (INIS)

    Hoffmann, E.

    1999-01-01

    The paper explains and illustrates the dissimilarity in design and equipment of control rooms in German NPPs, as well as a historical survey of the general principles and approaches applied in the evolution of control room technology, including backfitting activities. Experience obtained from daily operation as well training at the simulators is taken as a basis to formulate fundamental requirements for modification or novel design approaches. (orig./CB) [de

  17. The Performance-based Funding Scheme of Universities

    Directory of Open Access Journals (Sweden)

    Juha KETTUNEN

    2016-05-01

    Full Text Available The purpose of this study is to analyse the effectiveness of the performance-based funding scheme of the Finnish universities that was adopted at the beginning of 2013. The political decision-makers expect that the funding scheme will create incentives for the universities to improve performance, but these funding schemes have largely failed in many other countries, primarily because public funding is only a small share of the total funding of universities. This study is interesting because Finnish universities have no tuition fees, unlike in many other countries, and the state allocates funding based on the objectives achieved. The empirical evidence of the graduation rates indicates that graduation rates increased when a new scheme was adopted, especially among male students, who have more room for improvement than female students. The new performance-based funding scheme allocates the funding according to the output-based indicators and limits the scope of strategic planning and the autonomy of the university. The performance-based funding scheme is transformed to the strategy map of the balanced scorecard. The new funding scheme steers universities in many respects but leaves the research and teaching skills to the discretion of the universities. The new scheme has also diminished the importance of the performance agreements between the university and the Ministry. The scheme increases the incentives for universities to improve the processes and structures in order to attain as much public funding as possible. It is optimal for the central administration of the university to allocate resources to faculties and other organisational units following the criteria of the performance-based funding scheme. The new funding scheme has made the universities compete with each other, because the total funding to the universities is allocated to each university according to the funding scheme. There is a tendency that the funding schemes are occasionally

  18. Suppress flashover of GRP fire with water mist inside ISO 9705 Room

    Directory of Open Access Journals (Sweden)

    Qiang Xu

    2011-01-01

    Full Text Available Water mist suppression tests for glass-reinforced polyester (GRP panels were conducted in ISO 9705 room. GRP panels covered part of the room and a wood crib fire was used as fire source to ignite GRP fire. A four-nozzle water mist suppression equipment was used inside test room on the time of flashover. Heat release rate of the combustion inside the room, room temperature, surface temperature of GRP panels, total heat flux to wall, ceiling and floor in specific positions were measured. Gas concentration of O2, CO, and CO2 was also measured in the corner of the room at two different levels. A thermal image video was used to record the suppression procedure inside room. Test results show that the water mist system is efficient in suppressing the flashover of GRP fire and cooling the room within short time.

  19. New technologies for a postaccident control room habitability assessment

    International Nuclear Information System (INIS)

    Lahti, G.P.; Perchiazzi, W.T.

    1993-01-01

    Older nuclear power plants typically considered only a nominal amount of unfiltered in-leakage (typically 10 ft 3 /min) affecting their postaccident habitability. However, recent measurements of unfiltered in-leakage show leakages in excess of the nominal 10 ft 3 /m in. The assessment of postaccident doses in control rooms is done in a number of well-defined steps: (1) Determine the initial release of radioactivity to the containment (the open-quotes source termclose quotes). (2) Determine the release of radioactivity to the environment. (3) Determine the atmospheric dispersion and the concentration at the control room air intake. (4) Determine within-building dilution (if any). (5) Determine unfiltered in-leakage. (6) Determine the concentration of radioactivity in the control room. (7) Determine the dose to control room occupants. The prescriptive methodology of the Murphy-Campe paper and Standard Review Plan (SRP) 6.4 has been used by the U.S. Nuclear Regulatory Commission (NRC) to assess control room designs. However, a number of new technologies have been employed to reevaluate an existing pressurized water reactor plant design

  20. Medizin Curriculum Wien: neue Anforderungen an die Literatur- und Informationsversorgung für Studierende an der Universitätsbibliothek der Medizinischen Universität Wien / Medizin Curriculum Wien: New Demands for the Supply of Literature and Information to Students at the University Library of the Medical University of Vienna

    Directory of Open Access Journals (Sweden)

    Bauer, Bruno

    2005-09-01

    Full Text Available So far, students at medical faculties have intensively mainly used two services out of many, which specialized medical libraries have to offer: the textbook collection and the student reading room. Only towards the end of studies, in preparation of dissertations, do students take advantage of bibliographical databases and appropriate journals. During the last years, the medical curricula in many countries, including Germany and Austria, experienced considerable modifications. The reformation of the studies, which, in many cases, actually finds itself in the phase of implementation, is, in fact, a unique challenge for libraries. In support of medical studies, university lecturers and students expect information resources, library services and the relay of information competence, which should clearly surmount existing needs of the textbook collection and the student reading room, as shown in the available contribution, as example of the University Library of the Medical University of Vienna.

  1. Universality, Diversity and Legal Certainty: Cultural Diversity in the Dialogue between the CEDAW and States Parties

    NARCIS (Netherlands)

    Donders, Y.; Vleugel, V.; Kanetake, M.; Nollkaemper, A.

    2016-01-01

    It is broadly accepted that the universal value and application of international human rights norms does not imply a uniform implementation of these rights, thereby leaving room for local and culture specific implementation at the national level. The question remains, however, what the precise scope

  2. The Motivation to Study: An Analysis of Undergraduate Engineering Students at a Caribbean University

    Science.gov (United States)

    Maharaj, Chris; Blair, Erik; Chin Yuen Kee, Sarah

    2018-01-01

    The link between motivation and success is well documented; however, there is still room to problematise motivation in regards to the individual and contextual levels. This study looks at motivation in relation to students studying undergraduate engineering courses at a Caribbean university and seeks to discover the factors that motivate them to…

  3. Concentration Distribution in a Mixing Ventilated Room

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Pedersen, D.N.; Nielsen, Peter V.

    2001-01-01

    Today there is an increasing focus on the importance of a proper ventilation system to obtain good working conditions in the term of air and thermal quality to ensure high productivity. Different ventilation principles are used, e.g., mixing ventilation and displacement ventilation. In order...... that the air is fully mixed. The objective of this work is to determine the influence of the location of a pollutant, temperature differences and whether the room is furnished or not. It is also investigated if it is sufficient to determine the mean concentration in the room to determine the personal exposure....... Full scale experiments along with a breathing thermal manikin (BTM) have been used. The results show that the location of the sources is of great importance, just as well as temperature differences. Furthermore, the concentration in the breathing zone showed large differences throughout the room....

  4. Room for iodo therapy

    International Nuclear Information System (INIS)

    Pinto, A.L.A.; Derivi, A.; Bacelar, A.; Ramos, F.R.; Dias, T.M.; Baptista, I.S.

    1996-01-01

    A description of rules to assemble, to install and to maintain a room for iodo therapy is presented. The necessities of the patients and procedures to meet the norms of radiologic protection established by the Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil) are highlighted

  5. PAs and NPs in an emergency room-linked acute care clinic.

    Science.gov (United States)

    Currey, C J

    1984-12-01

    The use of hospital emergency rooms for nonurgent care during evenings hours often strains medical resources and may affect the quality of emergency care. One facility's effective use of an after-hours acute care clinic staffed by PAs and NPs to divert nonurgent problems away from its emergency room is outlined. PAs and NPs work during peak demand hours (evenings and weekends) under the supervision of an emergency room physician, and receive supplementary support from other emergency room personnel. Incoming patients are referred to the emergency room or acute care clinic, depending on the nature of their problems. Acute care clinic patients are then treated by the PA or NP and either released or referred to an emergency room physician, if their conditions warrant additional treatment. As a result, use of the acute care clinic has greatly reduced the amount of non-urgent medical treatment in the emergency room and has provided other advantages to both patients and staff as well. These advantages and the encouraging statistics following six months of the clinic's operation are discussed.

  6. Mathematical Programming Approaches for Optimal University Timetabling

    DEFF Research Database (Denmark)

    Bagger, Niels-Christian Fink

    Every semester universities are faced with the challenge of creating timetables for the courses. Creating these timetables is an important task to ensure that students can attend the courses they need for their education. Creating timetables that are feasible can be challenging, and when different...... are dedicated to this research field. This thesis considers a University Timetabling problem, more specifically the Curriculumbased Course Timetabling (CTT) problem. The objective of the CTT problem is to assign a set of lectures to time slots and rooms. The literature has focused mainly on heuristic...... applications which are also apparent in the different surveys. The drawback of the heuristics is that they are problem specific and do not provide any information on the quality of the solutions they generate. The objective of this thesis is to minimize the gap between the best-known upper bounds and the best...

  7. Ergonomics in the licensing and evaluation of nuclear reactors control room

    International Nuclear Information System (INIS)

    Santos, Isaac Jose Antonio Luquetti dos; Vidal, Mario Cesar Rodriguez

    2002-01-01

    A nuclear control room is a complex system that controls a thermodynamic process used to produce electrical energy. The operators interact with the control room through interfaces that have significant implications to nuclear plant safety and influence the operator activity. The TMI (Three Mile Island) accident demonstrated that only the anthropometric aspects were not enough for an adequate nuclear control room design. The studies showed that the accident was aggravated because the designers had not considered adequately human factor aspects. After TMI accident, the designers introduce in the nuclear control room development only human factors standards and human factors guidelines. The ergonomics approaches was not considered. Our objective is introduce in nuclear control room design and nuclear control room evaluation, a methodology that. includes human factors standards, human factors guidelines and ergonomic approaches, the operator activity analysis. (author)

  8. CDRH FOIA Electronic Reading Room

    Data.gov (United States)

    U.S. Department of Health & Human Services — The CDRH FOIA electronic reading room contains frequently requested information via the Freedom of Information Act from the Center for Devices and Radiological Health.

  9. Evaporation Controlled Emission in Ventilated Rooms

    DEFF Research Database (Denmark)

    Topp, Claus; Nielsen, Peter V.; Heiselberg, Per

    -scale ventilated room when the emission is fully or partly evaporation controlled. The objective of the present research work has been to investigate the change of emission rates from small-scale experiments to full-scale ventilated rooms and to investigate the influence of the local air velocity field near......Emission of volatile organic compounds (VOCs) from materials is traditionally determined from tests carried out in small-scale test chambers. However, a difference in scale may lead to a difference in the measured emission rate in a small-scale test chamber and the actual emission rate in a full...

  10. Emergency control room design of a nuclear reactor used to produce radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Isaac J.A.L. dos; Farias, Larissa P. de; Ponte, Luana T.L.; Goncalves, Gabriel L.; Castro, Heraclito M.; Farias, Marcos S.; Carvalho, Paulo V.R. de; Vianna Filho, Alfredo M.V., E-mail: luquetti@ien.gov.br [Instituto Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Departamento Engenharia Nuclear

    2015-07-01

    A control room is defined as a functional entity with an associated physical structure, where the operators carry out the centralized control, monitoring and administrative responsibilities. Emergency control room acts as an alternative control room for the purpose of shutting down or maintaining the facility in a safe shutdown state when the main control room is uninhabitable. The mission of emergency control room is to provide the resources to bring the plant to a safe shutdown condition after an evacuation of the main control room. An evacuation of the main control room is assumed when there is no possibility to accomplish tasks involved in the shutdown except reactor trip. The purpose of this paper is to present a specific approach for the design of the emergency control room of a nuclear reactor used to produce radioisotope. The approach is based on human factors standards and the participation of a multidisciplinary team in the development phase of the design. Using the information gathered from standards and from the multidisciplinary team a 3D Sketch and a 3D printing of the emergency control room were created. (author)

  11. Emergency control room design of a nuclear reactor used to produce radioisotope

    International Nuclear Information System (INIS)

    Santos, Isaac J.A.L. dos; Farias, Larissa P. de; Ponte, Luana T.L.; Goncalves, Gabriel L.; Castro, Heraclito M.; Farias, Marcos S.; Carvalho, Paulo V.R. de; Vianna Filho, Alfredo M.V.

    2015-01-01

    A control room is defined as a functional entity with an associated physical structure, where the operators carry out the centralized control, monitoring and administrative responsibilities. Emergency control room acts as an alternative control room for the purpose of shutting down or maintaining the facility in a safe shutdown state when the main control room is uninhabitable. The mission of emergency control room is to provide the resources to bring the plant to a safe shutdown condition after an evacuation of the main control room. An evacuation of the main control room is assumed when there is no possibility to accomplish tasks involved in the shutdown except reactor trip. The purpose of this paper is to present a specific approach for the design of the emergency control room of a nuclear reactor used to produce radioisotope. The approach is based on human factors standards and the participation of a multidisciplinary team in the development phase of the design. Using the information gathered from standards and from the multidisciplinary team a 3D Sketch and a 3D printing of the emergency control room were created. (author)

  12. Assessment of control rooms of nuclear power plants

    International Nuclear Information System (INIS)

    Norros, L.; Ranta, J.; Wahlstroem, B.

    1983-05-01

    To identify and correct the lacks in control rooms of operating power plants and plants under construction an extensive program has been started in the USA. In Finland as in other countries using nuclear power, the development in the USA particularly with regard to the requirements imposed on nuclear power plants is carefully followed. The changes in these requirements are sooner or later also reflected in the guidelines given by the Finnish authorities. It is therefore important to be able to form a notion of how the new requirements apply to Finnish conditions. Especially it is important to review the latest assessment guidelines for control room implementation (NUREG-0700). Thus we can avoid possible over hasty conclusions. The aim of the analysis of the method and experiments presented in NUREG 0700 report was to create a basis for assessment of the suitability of the method for Finnish control room implementation. The task group has made a general methodical analysis of the method, and partly tried it in assessment of the TVO2 control room. It is obvious that direct conclusions from the American situation are misleading. It can be considered unfeasible to follow the American requirements as such, because they can lead to unwanted results. If the review is limited to control room details, the NRC program (checklist) can be considered successful. It can also be used during planning to observation of small discrepancies. However, we can question the applicability of some requirements. It is, though, more essential that the control room entity has neither in this nor in several other programs been reached or standardized. In spite of the difficulties we should try to reach this most important goal. (author)

  13. Ship Design and Construction. An Integrated University Course

    DEFF Research Database (Denmark)

    Andersen, Poul; Jensen, Jørgen Juncher

    1996-01-01

    This paper describes an integrated course in design and construction of merchant ships taught at the Department of Naval Architecture andOffshore Engineering, the Technical University of Denmark. During the course, the students make a preliminary design of a ship of selected type and also design...... its engine room. The teaching combines lectures with laboratory work at the drawing tables and computer terminals. During the summer holiday, sea time on board ships of the relevant types are offered. Experienced naval architects from shipyards and ship consultancies give lectures and instructions...

  14. [Comprehensive system integration and networking in operating rooms].

    Science.gov (United States)

    Feußner, H; Ostler, D; Kohn, N; Vogel, T; Wilhelm, D; Koller, S; Kranzfelder, M

    2016-12-01

    A comprehensive surveillance and control system integrating all devices and functions is a precondition for realization of the operating room of the future. Multiple proprietary integrated operation room systems are currently available with a central user interface; however, they only cover a relatively small part of all functionalities. Internationally, there are at least three different initiatives to promote a comprehensive systems integration and networking in the operating room: the Japanese smart cyber operating theater (SCOT), the American medical device plug-and-play interoperability program (MDPnP) and the German secure and dynamic networking in operating room and hospital (OR.NET) project supported by the Federal Ministry of Education and Research. Within the framework of the internationally advanced OR.NET project, prototype solution approaches were realized, which make short-term and mid-term comprehensive data retrieval systems probable. An active and even autonomous control of the medical devices by the surveillance and control system (closed loop) is expected only in the long run due to strict regulatory barriers.

  15. Control room envelope unfiltered air inleakage test protocols

    International Nuclear Information System (INIS)

    Lagus, P.L.; Grot, R.A.

    1997-01-01

    In 1983, the Advisory Committee on Reactor Safeguards (ACRS) recommended that the US NRC develop a control room HVAC performance testing protocol. To date no such protocol has been forthcoming. Beginning in mid-1994, an effort was funded by NRC under a Small Business Innovation Research (SBIR) grant to develop several simplified test protocols based on the principles of tracer gas testing in order to measure the total unfiltered inleakage entering a CRE during emergency mode operation of the control room ventilation system. These would allow accurate assessment of unfiltered air inleakage as required in SRP 6.4. The continuing lack of a standard protocol is unfortunate since one of the significant parameters required to calculate operator dose is the amount of unfiltered air inleakage into the control room. Often it is assumed that, if the Control Room Envelope (CRE) is maintained at +1/8 in. w.g. differential pressure relative to the surroundings, no significant unfiltered inleakage can occur it is further assumed that inleakage due to door openings is the only source of unfiltered air. 23 refs., 13 figs., 2 tabs

  16. Control room envelope unfiltered air inleakage test protocols

    Energy Technology Data Exchange (ETDEWEB)

    Lagus, P.L. [Lagus Applied Technology, San Diego, CA (United States); Grot, R.A. [Lagus Applied Technology, Olney, MD (United States)

    1997-08-01

    In 1983, the Advisory Committee on Reactor Safeguards (ACRS) recommended that the US NRC develop a control room HVAC performance testing protocol. To date no such protocol has been forthcoming. Beginning in mid-1994, an effort was funded by NRC under a Small Business Innovation Research (SBIR) grant to develop several simplified test protocols based on the principles of tracer gas testing in order to measure the total unfiltered inleakage entering a CRE during emergency mode operation of the control room ventilation system. These would allow accurate assessment of unfiltered air inleakage as required in SRP 6.4. The continuing lack of a standard protocol is unfortunate since one of the significant parameters required to calculate operator dose is the amount of unfiltered air inleakage into the control room. Often it is assumed that, if the Control Room Envelope (CRE) is maintained at +1/8 in. w.g. differential pressure relative to the surroundings, no significant unfiltered inleakage can occur it is further assumed that inleakage due to door openings is the only source of unfiltered air. 23 refs., 13 figs., 2 tabs.

  17. Design process and philosophy of TVA's latest advance control room complex

    International Nuclear Information System (INIS)

    Owens, G.R.; Masters, D.W.

    1979-01-01

    TVA's latest nuclear power plant control room design includes a greater emphasis on human factors as compared to their earlier plant designs. This emphasis has resulted in changes in the overall design philosophy and design process. This paper discusses some of the prominent design features of both the control room and the surrounding control room complex. In addition, it also presents some of the important activities involved in the process of developing the advanced control room design

  18. Using Data Communication to Give Ease in Hotel Room Services

    Directory of Open Access Journals (Sweden)

    Rudi Tjiptadi

    2011-06-01

    Full Text Available Gaining extra comfort in a trip is an important factor. Staying in a hotel needs food, laundry, and other activities that can make guests comfortable. The guesses’ requests are usually ordered to the Room Service. Sometimes problems occur in serving the guests’ requests due to human error, such as overdue orders, misunderstandings, etc. Computers are used to prevent those problems by typing requests directly from a computer in the room. The method is done by collecting data from the direct interview at a hotel related to guests’ requests, analyzing the current system, doing literature study, creating a Room Service system draft, as well as implementing the new system in a form of prototype. A Room Service system prototype is created with the abilities to order food, drinks, laundry and ironing. This prototype designed meets the guests’ satisfaction towards the hotel room services. 

  19. The Active Listening Room Simulator: Part 2

    OpenAIRE

    Naqvi, Amber; Rumsey, Francis

    2001-01-01

    This paper presents the results of computer simulation of active reflectors in a reference listening room which are used to create artificial reflections in a two speaker, stereo listening configuration. This formulates the second phase of experiments in the active listening room project involving the analysis of computer modeling results and loudspeaker selection based on free field response. The aim of this project is to create a truly variable listening condition in a reference listening r...

  20. An Informationally Structured Room for Robotic Assistance

    Directory of Open Access Journals (Sweden)

    Tokuo Tsuji

    2015-04-01

    Full Text Available The application of assistive technologies for elderly people is one of the most promising and interesting scenarios for intelligent technologies in the present and near future. Moreover, the improvement of the quality of life for the elderly is one of the first priorities in modern countries and societies. In this work, we present an informationally structured room that is aimed at supporting the daily life activities of elderly people. This room integrates different sensor modalities in a natural and non-invasive way inside the environment. The information gathered by the sensors is processed and sent to a centralized management system, which makes it available to a service robot assisting the people. One important restriction of our intelligent room is reducing as much as possible any interference with daily activities. Finally, this paper presents several experiments and situations using our intelligent environment in cooperation with our service robot.

  1. Modern control room design experience and speculation

    International Nuclear Information System (INIS)

    Smith, J.E.

    1993-01-01

    Can operators trained to use conventional control panels readily adapt to CRT based control rooms? Does automation make the design of good man-machine interfaces more or less difficult? In a conventional, hard-wired control room is the operator's peripheral vision always an asset and how can one do better in a CRT based control room? Are Expert System assisted man-machine interfaces a boon or a bust? This paper explores these questions in the light of actual experience with advanced power plant control environments. This paper discusses how automation has in fact simplified the problem of ensuring that the operator has at all times a clear understanding of the plant state. The author contends that conventional hard-wired control rooms are very poor at providing the operator with a good overview of the plant status particularly under startup, or upset conditions and that CRT-based control rooms offer an opportunity for improvement. Experience with some early attempts at this are discussed together with some interesting proposals from other authors. Finally the paper discusses the experience to date with expert system assisted man-machine interfaces. Although promising for the future progress has been slow. The amount of knowledge research required is often formidable and consequently costly. Often when an adequate knowledge base is finally acquired it turns out to be better to use it to increase the level of automation and thus simplify the operator's task. The risks are not any greater and automation offers more consistent operation. It is important also to carefully distinguish between expert system assisted display selection and expert system operator guidance. The first is intended to help the operator in his quest for information. The second attempts to guide the operator actions. The good and the bad points of each of these approaches is discussed

  2. ATLAS virtual visit features Al-Quds University, a Palestinian university with campuses in Abu Dis and al-Bireh.

    CERN Multimedia

    claudia marcelloni

    2012-01-01

    Mon, 02 Apr - 14:00 CET (15:00 local) ATLAS virtual visit features Al-Quds University, a Palestinian university with campuses in Abu Dis and al-Bireh. As part of the "Physics Without Frontiers" project, funded by ICTP, Al-Quds is hosting a one day particle physics masterclass. During the day the students are given an introduction to particle physics, the LHC and the ATLAS Experiment, before having the chance to analyse real LHC data. This virtual visit comprises of a live tour around the ATLAS control room and the opportunity to ask questions to the ATLAS physicists. Al-Quds Physics has active research in accelerators, biophysics, laser, nuclear & particle, plasma, and solid state. A new collaboration is underway Forschungszentrum Jülich in spintronics, bioelectronics Alquds Physics is involved in the regional synchrotron SESAME in Jordan. Members include nine states from the region and over 10 observers worldwide. SESAME was established a long the same philosophy behind building CERN.

  3. GERMINAÇÃO EM SEMENTES DE ESPÉCIES FLORESTAIS DA MATA ATLÂNTICA (LEGUMINOSEAE SOB CONDIÇÕES DE CASA DE VEGETAÇÃO GERMINATION OF SEEDS IN NATIVE FOREST SPECIES (LEGUMINOSEAE UNDER GREENHOUSE CONDITIONS

    Directory of Open Access Journals (Sweden)

    Adriane Oliveira Cunha

    2007-09-01

    ="justify">PALAVRAS-CHAVE: Espécies nativas; dormência; vigor.

    The present research aimed to evaluate pre-germinating treatments in order to overcome the dormancy of seeds of four (Leguminoseae native forest species of Brasilian ";Mata Atlântica";. The experiment was carried out in greenhouse at Centro de Ciências Agrárias of Universidade Federal da Paraíba, at Areia-PB, Brazil. ";Jatobá";, ";guapuruvu";, ";orelha-de-negro"; and ";madeira nova"; seeds were subjected to the following treatments: T1- lateral scarification,T2 - lateral scarification plus imbibition for 24 hours at room temperature; T3 - immersion in water at 50°C until cool; T4 - immersion in water at 60°C until cool; T5 - immersion in distilled water (24 hours at room temperature; T6- control. Sowing was done in trays using sand substrate. The traits evaluated were emergence and index of emergence speed. The results obtained indicate that ";jatobá"; seeds subjected to scarification followed by imbibition proved to produce more vigorous seedlings. Scarification without imbibition may be recomended as a pre-germinating treatment in ";orelha-de-negro"; seeds. Scarification followed or not by imbibition in water was also efficient in breaking the dormancy of ";guapuruvu"; seeds. However, no treatment used was efficient in overcoming the dormancy of ";madeira nova"; seeds.

    KEY-WORDS: Native forest species; dormancy; vigour.

  4. Room-Maid in Hotel

    Science.gov (United States)

    Hotel and Catering Industry Training Board, Wembley (England).

    This syllabus is intended for the use of training personnel in drawing up training programs for room-maids in hotels. Its main objective is to produce fully trained maids, thereby maintaining and raising standards. The syllabus is divided into three sections: Introducing to Housekeeping, Basic Tasks Performed by the Majority of Housekeeping…

  5. Estimation of acoustic resonances for room transfer function equalization

    DEFF Research Database (Denmark)

    Gil-Cacho, Pepe; van Waterschoot, Toon; Moonen, Marc

    2010-01-01

    Strong acoustic resonances create long room impulse responses (RIRs) which may harm the speech transmission in an acoustic space and hence reduce speech intelligibility. Equalization is performed by cancelling the main acoustic resonances common to multiple room transfer functions (RTFs), i...

  6. Tritium behavior intentionally released in the room

    International Nuclear Information System (INIS)

    Kobayashi, K.; Hayashi, T.; Iwai, Y.; Yamanishi, T.; Willms, R. S.; Carlson, R. V.

    2008-01-01

    To construct a fusion reactor with high safety and acceptability, it is necessary to establish and to ensure tritium safe handling technology. Tritium should be well-controlled not to be released to the environment excessively and to prevent workers from excess exposure. It is especially important to grasp tritium behavior in the final confinement area, such as the room and/or building. In order to obtain data for actual tritium behavior in a room and/or building, a series of intentional Tritium Release Experiments (TREs) were planned and carried out within a radiologically controlled area (main cell) at Tritium System Test Assembly (TSTA) in Los Alamos National Laboratory (LANL) under US-JAPAN collaboration program. These experiments were carried out three times. In these experiments, influence of a difference in the tritium release point and the amount of hydrogen isotope for the initial tritium behavior in the room were suggested. Tritium was released into the main cell at TSTA/LANL. The released tritium reached a uniform concentration about 30 - 40 minutes in all the experiments. The influence of the release point and the amount of hydrogen isotope were not found to be important in these experiments. The experimental results for the initial tritium behavior in the room were also simulated well by the modified three-dimensional eddy flow analysis code FLOW-3D. (authors)

  7. Operating Room Fires and Surgical Skin Preparation.

    Science.gov (United States)

    Jones, Edward L; Overbey, Douglas M; Chapman, Brandon C; Jones, Teresa S; Hilton, Sarah A; Moore, John T; Robinson, Thomas N

    2017-07-01

    Operating room fires are "never events" that remain an under-reported source of devastating complications. One common set-up that promotes fires is the use of surgical skin preparations combined with electrosurgery and oxygen. Limited data exist examining the incidence of fires and surgical skin preparations. A standardized, ex vivo model was created with a 15 × 15 cm section of clipped porcine skin. An electrosurgical "Bovie" pencil was activated for 2 seconds on 30 Watts coagulation mode in 21% oxygen (room air), both immediately and 3 minutes after skin preparation application. Skin preparations with and without alcohol were tested, and were applied with and without pooling. Alcohol-based skin preparations included 70% isopropyl alcohol (IPA) with 2% chlorhexidine gluconate, 74% IPA with 0.7% iodine povacrylex, and plain 70% IPA. No fires occurred with nonalcohol-based preparations (p fires occurred in 38% (23 of 60) at 0 minutes and 27% (16 of 60) at 3 minutes. Alcohol-based skin preparations fuel operating room fires in common clinical scenarios. Following manufacturer guidelines and allowing 3 minutes for drying, surgical fires were still created in 1 in 10 cases without pooling and more than one-quarter of cases with pooling. Surgeons can decrease the risk of an operating room fire by using nonalcohol-based skin preparations or avoiding pooling of the preparation solution. Published by Elsevier Inc.

  8. Low frequency sound field enhancement system for rectangular rooms, using multiple loudspeakers

    DEFF Research Database (Denmark)

    Celestinos, Adrian

    2007-01-01

    The scope of this PhD dissertation is within the performance of loudspeakers in rooms at low frequencies. The research concentrates on the improvement of the sound level distribution in rooms produced by loudspeakers at low frequencies. The work focuses on seeing the problem acoustically...... and solving it in the time domain. Loudspeakers are the last link in the sound reproduction chain, and they are typically placed in small or medium size rooms. When low frequency sound is radiated by a loudspeaker the sound level distribution along the room presents large deviations. This is due...... to the multiple reflection of sound at the rigid walls of the room. This may cause level differences of up to 20 dB in the room. Some of these deviations are associated with the standing waves, resonances or anti resonances of the room. The understanding of the problem is accomplished by analyzing the behavior...

  9. 3D visualization based customer experiences of nuclear plant control room

    International Nuclear Information System (INIS)

    Sun Tienlung; Chou Chinmei; Hung Tamin; Cheng Tsungchieh; Yang Chihwei; Yang Lichen

    2011-01-01

    This paper employs virtual reality (VR) technology to develop an interactive virtual nuclear plant control room in which the general public could easily walk into the 'red zone' and play with the control buttons. The VR-based approach allows deeper and richer customer experiences that the real nuclear plant control room could not offer. When people know more about the serious process control procedures enforced in the nuclear plant control room, they will appropriate more about the safety efforts imposed by the nuclear plant and become more comfortable about the nuclear plant. The virtual nuclear plant control room is built using a 3D game development tool called Unity3D. The 3D scene is connected to a nuclear plant simulation system through Windows API programs. To evaluate the usability of the virtual control room, an experiment will be conducted to see how much 'immersion' the users could feel when they played with the virtual control room. (author)

  10. NRC study of control room habitability

    International Nuclear Information System (INIS)

    Hayes, J.J. Jr.; Muller, D.R.; Gammill, W.P.

    1985-01-01

    Since 1980, the Advisory Committee on Reactor Safeguards (ACRS) has held several meetings with the NRC staff to discuss the subject of control room habitability. Several meetings between the ACRS and the staff have resulted in ACRS letters that express specific concerns, and the staff has provided responses in reports and meetings. In June of 1983, the NRC Executive Director for Operations directed the Offices of Nuclear Reactor Regulation and Inspection and Enforcement to develop a plan to handle the issues raised by the ACRS and to report to him specific proposed courses of action to respond to the ACRS's concerns. The NRC control room habitability working group has reviewed the subject in such areas as NRR review process, transformation of control room habitability designs to as-built systems, and determination of testing protocol. The group has determined that many of the ACRS concerns and recommendations are well founded, and has recommended actions to be taken to address these as well as other concerns which were raised independent of the ACRS. The review has revealed significant areas where the approach presently utilized in reviews should be altered

  11. Continuous-wave room-temperature diamond maser

    Science.gov (United States)

    Breeze, Jonathan D.; Salvadori, Enrico; Sathian, Juna; Alford, Neil Mcn.; Kay, Christopher W. M.

    2018-03-01

    The maser—the microwave progenitor of the optical laser—has been confined to relative obscurity owing to its reliance on cryogenic refrigeration and high-vacuum systems. Despite this, it has found application in deep-space communications and radio astronomy owing to its unparalleled performance as a low-noise amplifier and oscillator. The recent demonstration of a room-temperature solid-state maser that utilizes polarized electron populations within the triplet states of photo-excited pentacene molecules in a p-terphenyl host paves the way for a new class of maser. However, p-terphenyl has poor thermal and mechanical properties, and the decay rates of the triplet sublevel of pentacene mean that only pulsed maser operation has been observed in this system. Alternative materials are therefore required to achieve continuous emission: inorganic materials that contain spin defects, such as diamond and silicon carbide, have been proposed. Here we report a continuous-wave room-temperature maser oscillator using optically pumped nitrogen–vacancy defect centres in diamond. This demonstration highlights the potential of room-temperature solid-state masers for use in a new generation of microwave devices that could find application in medicine, security, sensing and quantum technologies.

  12. Overview of the LHD central control room data monitoring environment

    International Nuclear Information System (INIS)

    Emoto, M.; Yoshinuma, M.; Yoshida, M.; Nakanishi, H.; Iwata, C.; Ohsuna, M.; Nonomura, M.; Imazu, S.; Yokota, M.; Aoyagi, M.; Ogawa, H.; Ida, K.; Watanabe, K.; Kaneko, O.

    2016-01-01

    Highlights: • In this paper, the data monitoring environments in the LHD central control room, for example, summary data graph and video monitoring tools are introduced. Also, the environments for the remote participants are introduced. - Abstract: During the Large Helical Device (LHD) experiments, many scientists and technical staff are working in the central control room to operate the experiment. They must manage the diagnostics and controlling devices referring to the results of the last plasma shot. Also, the experiment coordinator must decide the conditions for the subsequent experiments using the results. Furthermore, many scientists are participating in the experiment from remote sites. Therefore, it is important to share the information in the control room quickly, such as the results of the last plasma discharge, with the remote user as well as with the staff in the room. In this paper, the data monitoring environment in the LHD central control room is introduced.

  13. Overview of the LHD central control room data monitoring environment

    Energy Technology Data Exchange (ETDEWEB)

    Emoto, M., E-mail: emoto.masahiko@nifs.ac.jp; Yoshinuma, M.; Yoshida, M.; Nakanishi, H.; Iwata, C.; Ohsuna, M.; Nonomura, M.; Imazu, S.; Yokota, M.; Aoyagi, M.; Ogawa, H.; Ida, K.; Watanabe, K.; Kaneko, O.

    2016-11-15

    Highlights: • In this paper, the data monitoring environments in the LHD central control room, for example, summary data graph and video monitoring tools are introduced. Also, the environments for the remote participants are introduced. - Abstract: During the Large Helical Device (LHD) experiments, many scientists and technical staff are working in the central control room to operate the experiment. They must manage the diagnostics and controlling devices referring to the results of the last plasma shot. Also, the experiment coordinator must decide the conditions for the subsequent experiments using the results. Furthermore, many scientists are participating in the experiment from remote sites. Therefore, it is important to share the information in the control room quickly, such as the results of the last plasma discharge, with the remote user as well as with the staff in the room. In this paper, the data monitoring environment in the LHD central control room is introduced.

  14. Shield design of concrete wall between decay tank room and primary pump room in TRIGA facility

    International Nuclear Information System (INIS)

    Khan, M. J. H.; Rahman, M.; Haque, A.; Zulquarnain, A.; Ahmed, F. U.; Bhuiyan, S. I.

    2007-01-01

    The objective of this study is to recommend the radiation protection design parameters from the shielding point of view for concrete wall between the decay tank room and the primary pump room in TRIGA Mark-II research reactor facility. The shield design for this concrete wall has been performed with the help of Point-kernel Shielding Code Micro-Shield 5.05 and this design was also validated based on the measured dose rate values with Radiation Survey Meter (G-M Counter) considering the ICRP-60 (1990) recommendations for occupational dose rate limit (10 μSv/hr). The recommended shield design parameters are: (i) thickness of 114.3 cm Ilmenite-Magnetite Concrete (IMC) or 129.54 cm Ordinary Reinforced Concrete (ORC) for concrete wall A (ii) thickness of 66.04 cm Ilmenite-Magnetite Concrete (IMC) or 78.74 cm Ordinary Reinforced Concrete (ORC) for concrete wall B and (iii) door thickness of 3.175 cm Mild Steel (MS) on the entrance of decay tank room. In shielding efficiency analysis, the use of I-M concrete in the design of this concrete wall shows that it reduced the dose rate by a factor of at least 3.52 times approximately compared to ordinary reinforced concrete

  15. Computer vision based room interior design

    Science.gov (United States)

    Ahmad, Nasir; Hussain, Saddam; Ahmad, Kashif; Conci, Nicola

    2015-12-01

    This paper introduces a new application of computer vision. To the best of the author's knowledge, it is the first attempt to incorporate computer vision techniques into room interior designing. The computer vision based interior designing is achieved in two steps: object identification and color assignment. The image segmentation approach is used for the identification of the objects in the room and different color schemes are used for color assignment to these objects. The proposed approach is applied to simple as well as complex images from online sources. The proposed approach not only accelerated the process of interior designing but also made it very efficient by giving multiple alternatives.

  16. Control room habitability system review models

    International Nuclear Information System (INIS)

    Gilpin, H.

    1990-12-01

    This report provides a method of calculating control room operator doses from postulated reactor accidents and chemical spills as part of the resolution of TMI Action Plan III.D.3.4. The computer codes contained in this report use source concentrations calculated by either TACT5, FPFP, or EXTRAN, and transport them via user-defined flow rates to the control room envelope. The codes compute doses to six organs from up to 150 radionuclides (or 1 toxic chemical) for time steps as short as one second. Supporting codes written in Clipper assist in data entry and manipulation, and graphically display the results of the FORTRAN calculations. 7 refs., 22 figs

  17. The influence of the directivity of musical instruments in a room

    DEFF Research Database (Denmark)

    Otondo, Felipe; Rindel, Jens Holger

    2004-01-01

    Measurements of the directivity of musical instruments are presented as part of the study of the influence of their representation in room acoustic simulations and auralizations. Pairs of measured and averaged directivities have been used both for room simulation comparisons and as a basis...... for listening experiments with auralizations. Room simulation results show a clear influence of the changes in the representation directivity on the distribution of acoustical parameters in the room. The results of the listening experiments with auralizations show that some changes produced by directivity...

  18. Design Considerations for Abrasive Blast Rooms and Recovery Systems

    Science.gov (United States)

    2010-02-01

    COLUMN BOLT – ALLOWS FOR WIDER ENCLOSURES – STRONG ENOUGH TO SUPPORT MONORAIL Flange Bolt Room Column Bolt Room • Structural steel framework...OVERHEAD MONORAILS • EXTERIOR WORK STATIONS • TURNTABLES • HORIZONTAL ROTATION DEVICES OVERHEAD MONORAIL Workpiece Handling • Powered horizontal rotation

  19. Teamwork and problem solving in the control room

    International Nuclear Information System (INIS)

    Nygard, F.I.; Dedon, J.M.; Fuld, R.B.

    1989-01-01

    The importance of teamwork and communications in the control room of a nuclear power plant has been the subject of significant attention during the 10 yr since the Three Mile Island accident. The ability to conduct effective problem solving, especially under unexpected conditions, requires that the control room crew be well trained in techniques that produce synergism and avoid ambiguous or conflicting interactions. This paper describes the foundations of a training program developed and conducted by Combustion Engineering to produce a winning team in the control room. The complete licensed operations staffs of three utilities, Florida Power ampersand Light, Louisiana Power ampersand Light, and Omaha Public Power District, have completed this program. Thus, the results of the experience of ∼150 licensed operators is reported

  20. A Research Framework for Demonstrating Benefits of Advanced Control Room Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Le Blanc, Katya [Idaho National Lab. (INL), Idaho Falls, ID (United States); Boring, Ronald [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hallbert, Bruce [Idaho National Lab. (INL), Idaho Falls, ID (United States); Thomas, Kenneth [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-12-01

    Control Room modernization is an important part of life extension for the existing light water reactor fleet. None of the 99 currently operating commercial nuclear power plants in the U.S. has completed a full-scale control room modernization to date. A full-scale modernization might, for example, entail replacement of all analog panels with digital workstations. Such modernizations have been undertaken successfully in upgrades in Europe and Asia, but the U.S. has yet to undertake a control room upgrade of this magnitude. Instead, nuclear power plant main control rooms for the existing commercial reactor fleet remain significantly analog, with only limited digital modernizations. Previous research under the U.S. Department of Energy’s Light Water Reactor Sustainability Program has helped establish a systematic process for control room upgrades that support the transition to a hybrid control. While the guidance developed to date helps streamline the process of modernization and reduce costs and uncertainty associated with introducing digital control technologies into an existing control room, these upgrades do not achieve the full potential of newer technologies that might otherwise enhance plant and operator performance. The aim of the control room benefits research presented here is to identify previously overlooked benefits of modernization, identify candidate technologies that may facilitate such benefits, and demonstrate these technologies through human factors research. This report serves as an outline for planned research on the benefits of greater modernization in the main control rooms of nuclear power plants.

  1. A Research Framework for Demonstrating Benefits of Advanced Control Room Technologies

    International Nuclear Information System (INIS)

    Le Blanc, Katya; Boring, Ronald; Joe, Jeffrey; Hallbert, Bruce; Thomas, Kenneth

    2014-01-01

    Control Room modernization is an important part of life extension for the existing light water reactor fleet. None of the 99 currently operating commercial nuclear power plants in the U.S. has completed a full-scale control room modernization to date. A full-scale modernization might, for example, entail replacement of all analog panels with digital workstations. Such modernizations have been undertaken successfully in upgrades in Europe and Asia, but the U.S. has yet to undertake a control room upgrade of this magnitude. Instead, nuclear power plant main control rooms for the existing commercial reactor fleet remain significantly analog, with only limited digital modernizations. Previous research under the U.S. Department of Energy's Light Water Reactor Sustainability Program has helped establish a systematic process for control room upgrades that support the transition to a hybrid control. While the guidance developed to date helps streamline the process of modernization and reduce costs and uncertainty associated with introducing digital control technologies into an existing control room, these upgrades do not achieve the full potential of newer technologies that might otherwise enhance plant and operator performance. The aim of the control room benefits research presented here is to identify previously overlooked benefits of modernization, identify candidate technologies that may facilitate such benefits, and demonstrate these technologies through human factors research. This report serves as an outline for planned research on the benefits of greater modernization in the main control rooms of nuclear power plants.

  2. Empathy and well-being correlate with centrality in different social networks.

    Science.gov (United States)

    Morelli, Sylvia A; Ong, Desmond C; Makati, Rucha; Jackson, Matthew O; Zaki, Jamil

    2017-09-12

    Individuals benefit from occupying central roles in social networks, but little is known about the psychological traits that predict centrality. Across four college freshman dorms ( n = 193), we characterized individuals with a battery of personality questionnaires and also asked them to nominate dorm members with whom they had different types of relationships. This revealed several social networks within dorm communities with differing characteristics. In particular, additional data showed that networks varied in the degree to which nominations depend on ( i ) trust and ( ii ) shared fun and excitement. Networks more dependent upon trust were further defined by fewer connections than those more dependent on fun. Crucially, network and personality features interacted to predict individuals' centrality: people high in well-being (i.e., life satisfaction and positive emotion) were central to networks characterized by fun, whereas people high in empathy were central to networks characterized by trust. Together, these findings provide network-based corroboration of psychological evidence that well-being is socially attractive, whereas empathy supports close relationships. More broadly, these data highlight how an individual's personality relates to the roles that they play in sustaining their community.

  3. UNIDADES DE FRIO PARA MACIEIRAS NA REGIÃO DE VACARIA – RS, BRASIL

    Directory of Open Access Journals (Sweden)

    LOANA SILVEIRA CARDOSO

    2015-06-01

    Full Text Available As macieiras necessitam de um período de acumulação de frio para a quebra da dormência das gemas. Neste estudo, as unidades de frioforam quantificadas por diferentes métodos de cálculo para a região de Vacaria-RS, Brasil, a fim de compará-las com as necessidades de macieiras ‘Gala’ e ‘Fuji’. As unidades de frio foram calculadas para o período de2000/2009, através dos seguintes métodos: Horas de Frio Ponderadas, Utah, Carolina do Norte, Utah Modificado e Carolina do Norte Modificado. Na região estudada, o número de unidades de frio apresenta altavariabilidade entre os anos, independentemente dos métodos de cálculo. Mesmo em anos com alta disponibilidade de horas de frio, o número de unidades de frio necessárias para a quebra de dormência em macieiras ‘Gala’ e ‘Fuji’ não é alcançado, naturalmente. Maio, junho e julho é o principal trimestre para acumular unidades de frio, durante o período de dormência de gemas de macieira.

  4. Konsep Visual Sistem Sarana Isyarat Penunjuk (Sign System di Kampus Syahdan Binus University

    Directory of Open Access Journals (Sweden)

    Rina Kartika

    2010-10-01

    Full Text Available  Limited signage facilities in Syahdan Campus of Binus University, has often been the cause of the disruption of the activities of the users who are unfamiliar with the room layout in the building. Where in this case teaching and learning activities are only one of the activities conducted there,  and it has to be considered that users are not only from among the faculty and students only, as regular users, but also visitors and guests as incidental users. Common problems in finding rooms that they have to go to, is usually only solved by asking someone else. Design of an effective, communicative, applicative and integrated sign system, is considered to be a solution to this problem. 

  5. The Tea Culture and Its Forms Across the Czech Tea Rooms

    OpenAIRE

    Schröderová, Karolína

    2015-01-01

    In this bachelor thesis I have focused on the Czech tea culture across tea rooms. I have described the specifics of the tea rooms and of the tea culture. Furthermore I am dealing with ways of tea culture spreading, and what is the process of the tea room establishing. I am using the term of subculture in the connection with the tea culture, its meaning and position in the Czech culture. The main data source were semi-structured interviews with the tea rooms owners, all complemented by a parti...

  6. 222radon and its alpha decay concentration into university in Cluj

    International Nuclear Information System (INIS)

    Neda, T.; Mocsy, I.; Tonk, S.

    2004-01-01

    The Bocskai house is an old building in the middle of Kolozsvar city. It was built in 1550. Now it host the Hungarian University Rector's Office and the Faculty of Science and Art, after many modifications. The building has 3 levels. We determined the radon activity concentration and the concentrations of its short-lived daughters in 12 different rooms used for education and as office rooms. The measurements were done with ionization chambers in different conditions in 24 h cycle in the period of 2003-2004. Simultaneously we measured ambient temperature, pressure and relative humidity of the air. We found that the radon activity concentration had values between 40 - 1800 Bq.m-3. Based on the measurements we estimated the exposure from radon and its short lived daughters of the people who work in this building. (author)

  7. An electronic logbook for the HEP control room

    International Nuclear Information System (INIS)

    Roediger, G.; Pomatto, P.; Kyriakopulos, J.; Panacek, S.; Canal, P.; Kubarovsky, A.

    2001-01-01

    The Control Room Logbook (CRL) is designed to improve and replace the paper logbooks traditionally used in the HEP accelerator control room. Its features benefit the on-line coordinator, the shift operators, and the remote observers. The author explains some of the most attractive features for each of these roles. The features include the ability to configure the logbook for the specific needs of a collaboration, a large variety of entry types an operator can add by simply clicking and dragging, and a flexible web interface for the remote observer to keep up with control room activities. The entries and saved as UTF-8 based XML files, which allowed us to give the data structure and meaning such that it can easily be parsed in the present and far into the future. The XML tag data is also indexed in a relational database, making queries on dates, keywords, entry type and other criteria feasible and fast. The CRL is used in the D0 control room. This presentation also discusses our experience with deployment, platform independence and other interesting issues that arose with the installation and use of logbook

  8. An Electronic Logbook for the HEP Control Room

    International Nuclear Information System (INIS)

    Gary Roediger

    2001-01-01

    The Control Room Logbook (CRL) is designed to improve and replace the paper logbooks traditionally used in the HEP accelerator control room. Its features benefit the on-line coordinator, the shift operators, and the remote observers. This paper explains some of the most attractive features for each of these roles. The features include the ability to configure the logbook for the specific needs of a collaboration, a large variety of entry types an operator can add by simply clicking and dragging, and a flexible web interface for the remote observer to keep up with control room activities. The entries are saved as UTF-8 based XML files, which allowed us to give the data structure and meaning such that it can easily be parsed in the present and far into the future. The XML tag data is also indexed in a relational database, making queries on dates, keywords, entry type and other criteria feasible and fast. The CRL is used in the D0 control room. This presentation also discusses our experience with deployment, platform independence and other interesting issues that arose with the installation and use of the logbook

  9. Information Foraging in Nuclear Power Plant Control Rooms

    International Nuclear Information System (INIS)

    Boring, R.L.

    2011-01-01

    nformation foraging theory articulates the role of the human as an 'informavore' that seeks information and follows optimal foraging strategies (i.e., the 'information scent') to find meaningful information. This paper briefly reviews the findings from information foraging theory outside the nuclear domain and then discusses the types of information foraging strategies operators employ for normal and off-normal operations in the control room. For example, operators may employ a predatory 'wolf' strategy of hunting for information in the face of a plant upset. However, during routine operations, the operators may employ a trapping 'spider' strategy of waiting for relevant indicators to appear. This delineation corresponds to information pull and push strategies, respectively. No studies have been conducted to determine explicitly the characteristics of a control room interface that is optimized for both push and pull information foraging strategies, nor has there been empirical work to validate operator performance when transitioning between push and pull strategies. This paper explores examples of control room operators as wolves vs. spiders and con- cludes by proposing a set of research questions to investigate information foraging in control room settings.

  10. Information Foraging in Nuclear Power Plant Control Rooms

    Energy Technology Data Exchange (ETDEWEB)

    R.L. Boring

    2011-09-01

    nformation foraging theory articulates the role of the human as an 'informavore' that seeks information and follows optimal foraging strategies (i.e., the 'information scent') to find meaningful information. This paper briefly reviews the findings from information foraging theory outside the nuclear domain and then discusses the types of information foraging strategies operators employ for normal and off-normal operations in the control room. For example, operators may employ a predatory 'wolf' strategy of hunting for information in the face of a plant upset. However, during routine operations, the operators may employ a trapping 'spider' strategy of waiting for relevant indicators to appear. This delineation corresponds to information pull and push strategies, respectively. No studies have been conducted to determine explicitly the characteristics of a control room interface that is optimized for both push and pull information foraging strategies, nor has there been empirical work to validate operator performance when transitioning between push and pull strategies. This paper explores examples of control room operators as wolves vs. spiders and con- cludes by proposing a set of research questions to investigate information foraging in control room settings.

  11. Energy Efficiency in Small Server Rooms: Field Surveys and Findings

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Iris [Hoi; Greenberg, Steve; Mahdavi, Roozbeh; Brown, Richard; Tschudi, William

    2014-08-11

    Fifty-seven percent of US servers are housed in server closets, server rooms, and localized data centers, in what are commonly referred to as small server rooms, which comprise 99percent of all server spaces in the US. While many mid-tier and enterprise-class data centers are owned by large corporations that consider energy efficiency a goal to minimize business operating costs, small server rooms typically are not similarly motivated. They are characterized by decentralized ownership and management and come in many configurations, which creates a unique set of efficiency challenges. To develop energy efficiency strategies for these spaces, we surveyed 30 small server rooms across eight institutions, and selected four of them for detailed assessments. The four rooms had Power Usage Effectiveness (PUE) values ranging from 1.5 to 2.1. Energy saving opportunities ranged from no- to low-cost measures such as raising cooling set points and better airflow management, to more involved but cost-effective measures including server consolidation and virtualization, and dedicated cooling with economizers. We found that inefficiencies mainly resulted from organizational rather than technical issues. Because of the inherent space and resource limitations, the most effective measure is to operate servers through energy-efficient cloud-based services or well-managed larger data centers, rather than server rooms. Backup power requirement, and IT and cooling efficiency should be evaluated to minimize energy waste in the server space. Utility programs are instrumental in raising awareness and spreading technical knowledge on server operation, and the implementation of energy efficiency measures in small server rooms.

  12. Control room MMI 2000 for NORS simulator in HAMMLAB

    International Nuclear Information System (INIS)

    Saarni, R.; Foerdestroemmen, N.T.; Meyer, B.D.; Skjerve, A.B.M.

    2001-03-01

    The report presents the control room MMI as of year 2000 for the NORS simulator in HAMMLAB. It consists of two main parts: NORS Reference Control Room MMI and NORS Experimental Control Room MMI. They are both utilised in human factors experiments in HAMMLAB. The HAMMLAB Experimental Control Room 2000 is presented together with the NORS Reference CR MMI, which includes the following display types: Overview displays, process and control displays, trend displays, supplementary alarm displays and logic displays for the protection system and other automatic control systems. User experiences based on feedback from professional Loviisa NPP operators are also given. For the Experimental Control Room MMI, main emphasis is on presenting the design of a new large screen overview display called; experimental Automatic Information Presentation (AIP) display. It was used for the first time last year in the HCA-2000 experiment in HAMMLAB. The design is quite different from previous overview displays being developed and used in HAMMLAB. The display presents the overall dynamic status of both the process and the automatic systems. The plans for the future include to develop and user test an upgraded AIP overview display, and to enhance and user test a limited set of task-based display prototypes. (Author)

  13. Evaluation of in vitro antibacterial effect of room curing polymethylmethacrylate material adding nano-silver base inorganic antibacterial agents

    International Nuclear Information System (INIS)

    Jia Chunli; Wang Xiaorong; Zhang Citong; Sun Shiqun; Yang Yun

    2012-01-01

    Objective: To investigate the antibacterial effect of room curing polymethylmethacrylate (PMMA) material adding nano-silver base inorganic antibacterial agent and to detect the changes of its mechanical property. Methods: Nano-silver base inorganic antibacterial agent was added to the room curing PMMA material in the range of 0.5% -3.0% at an interval of 0.5% by ball milling specimen. Antibacterial rates of the specimens were detected by film method. Bending strength, impact strength, and wear resistance of the specimens were respectively detected on electronic universal testing machine, impact test machine and friction and wear test machine. Results: The antibacterial rates of Streptococcus mutans and Candida albicans were more than 50% when antibiotics content was 1.0% . The antibacterial rates of Streptococcus mutans and Candida albicans were more than 90% when the antibiotics content was 2.5% . The three mechanical properties were increased compared with control group when the antibacterial agents were in the range of 1.0% -1.5% . Then the three mechanical properties were decreased with the increasing of antimicrobial concentration. When the antibiotics content was 2.0% , the wear resistance had significant difference compared with control group (P<0.05); when the antibiotics content was 2.5% , the bending strength and impact strength had significant difference compared with control group (P<0.05). Conclusion: The antibacterial effect of room curing PMMA adding nano-silver base inorganic antibacterial agent is ideal. The antibacterial rate is increased gradually with the increasing content of antibacterial agents. There is no significant effect on the mechanical properties of room curing PMMA material, but the antibacterial effects are satisfied when the content of antibacterial agents is 2.0% . (authors)

  14. Human-factors engineering control-room design review/audit: Waterford 3 SES Generating Station, Louisiana Power and Light Company

    International Nuclear Information System (INIS)

    Savage, J.W.

    1983-01-01

    A human factors engineering design review/audit of the Waterford-3 control room was performed at the site on May 10 through May 13, 1982. The report was prepared on the basis of the HFEB's review of the applicant's Preliminary Human Engineering Discrepancy (PHED) report and the human factors engineering design review performed at the site. This design review was carried out by a team from the Human Factors Engineering Branch, Division of Human Factors Safety. The review team was assisted by consultants from Lawrence Livermore National Laboratory (University of California), Livermore, California

  15. Room temperature exchange bias in SmFeO_3 single crystal

    International Nuclear Information System (INIS)

    Wang, Xiaoxiong; Cheng, Xiangyi; Gao, Shang; Song, Junda; Ruan, Keqing; Li, Xiaoguang

    2016-01-01

    Exchange bias phenomenon is generally ascribed to the unidirectional magnetic shift along the field axes at interface of two magnetic materials. Room temperature exchange bias is found in SmFeO_3 single crystal. The behavior after different cooling procedure is regular, and the training behavior is attributed to the athermal training and its pinning origin is attributed to the antiferromagnetic clusters. Its being single phase and occurring at room temperature make it an appropriate candidate for application. - Graphical abstract: Room temperature exchange bias was found in oxide single crystal. Highlights: • Room temperature exchange bias has been discovered in single-crystalline SmFeO_3. • Its pinning origin is attributed to the antiferromagnetic clusters. • Its being single phase and occurring at room temperature make it an appropriate candidate for application.

  16. Evaluation of room acoustic qualities and defects by use of auralization

    DEFF Research Database (Denmark)

    Rindel, Jens Holger

    2004-01-01

    Auralizations generated by room acoustic computer modeling programs may be used as a tool for evaluation of acoustic qualities and defects, some of which are not easily detected by objective measures. Examples include reverberance, flutter echoes, perceived room size and distance, apparent source...... that the modeling of source directivity and the late room reflections (the reverberation tail) need careful consideration in order to achieve reliable and realistic sounding results. However, when implemented in the software the application for practical use can be simple and quick....... width, listener envelopment, and sound propagation in coupled rooms. In order to reach a sufficiently high level of realism in auralizations for such room acoustic applications it is necessary that all parts of the simulation chain are modeled with sufficient accuracy. In particular it is found...

  17. EscapED: A Framework for Creating Educational Escape Rooms and Interactive Games to For Higher/Further Education.

    Directory of Open Access Journals (Sweden)

    Samantha Jane Clarke

    2017-09-01

    Full Text Available Game-based learning (GBL is often found to be technologically driven and more often than not, serious games for instance, are conceptualised and designed solely for digital platforms and state of the art technologies. To encourage a greater discussion on the potential benefits and challenges of a more holistic approach to developing GBL that promote human centered interactions and play for learning, the authors present the escapED programme. The escapED programme was conceived following the recent entertainment trend of escape rooms and is used for developing non-digital GBL approaches within education. escapED aids the design and creation of educational Escape Rooms and Interactive Gaming Experiences for staff and students in further/higher education settings. The paper first presents a pilot study that was used to assess the feasibility and acceptance of University teaching staff of embedding interactive GBL into a higher education environment. The authors then present the escapED theoretical framework that was used to create the prototype game for the pilot study as a tool to aid future design and development of on-site interactive experiences. The paper also presents an external developer report of using the escapED framework to develop a prototype game for teaching research methods to Southampton University students. Finally, the authors present a discussion on the use of the escapED framework so far and plans for future work and evaluation in order to provide engaging alternatives for learning and soft skills development amongst higher education staff andstudents.

  18. An assessment of the quality indicators of operative and non-operative times in a public university hospital.

    Science.gov (United States)

    Costa, Altair da Silva; Leão, Luiz Eduardo Villaça; Novais, Maykon Anderson Pires de; Zucchi, Paola

    2015-01-01

    To assess the operative time indicators in a public university hospital. A descriptive cross-sectional study was conducted using data from operating room database. The sample was obtained from January 2011 to January 2012. The operations performed in sequence in the same operating room, between 7:00 am and 5:00 pm, elective or emergency, were included. The procedures with incomplete data in the system were excluded, as well as the operations performed after 5:00 pm or on weekends or holidays. We measured the operative and non-operative time of 8,420 operations. The operative time (mean and standard deviation) of anesthesias and operations were 177.6 ± 110 and 129.8 ± 97.1 minutes, respectively. The total time of the patient in operative room (mean and standard deviation) was 196.8 ± 113.2. The non-operative time, e.g., between the arrival of the patient and the onset of anesthesia was 14.3 ± 17.3 minutes. The time to set the next patient in operating room was 119.8 ± 79.6 minutes. Our total non-operative time was 155 minutes. Delays frequently occurred in our operating room and had a major effect on patient flow and resource utilization. The non-operative time was longer than the operative time. It is possible to increase the operating room capacity by management and training of the professionals involved. The indicators provided a tool to improve operating room efficiency.

  19. CMS inner detector assembled in a clean room

    CERN Multimedia

    Serge Bellegarde

    2006-01-01

    The inner detector for the CMS experiment is assembled in a specially designed clean room. These rooms are sealed so that impurities in the air do not get trapped in the detector while it is being assembled. This inner detector will eventually be installed at the heart of the CMS experiment, taking measurements of particles produced in the collision of either proton or lead beams.

  20. Firearm Injuries Received in Emergency Room of a Nigerian ...

    African Journals Online (AJOL)

    2017-05-22

    May 22, 2017 ... the emergency room of Federal Teaching Hospital Abakaliki from January 2005 to. December 2014. Results: There were 214 ... Hospital: Analysis of Pattern, Morbidity, and Mortality. NI Omoke. Original Article ..... rapid evacuation of casualties to hospital emergency room. In this study, there was no ...

  1. Christian IV's Winter Room and Studiolo at Rosenborg Castle

    DEFF Research Database (Denmark)

    Wadum, Jørgen

    2015-01-01

    An account of the creation of the highly decorated ensemble forming the Winter Room and the Writing Room, Christian 4s private quarters at Rosenborg Castle. Art historical, technical analysis reveals new evidence on the working practice of Danish and Antwerp artists and craftsmen in the first...

  2. How to Design and Equip a Mentalization-Based Play Therapy Room.

    Science.gov (United States)

    Rüth, Ulrich; Holch, Astrid

    2018-01-01

    Designing and equipping a play therapy room as a differentiated tool in a psychodynamic approach to child psychotherapy is seldom discussed. This article sketches out the equipment and furnishing of a play therapy room to be used for mentalization-based psychodynamic psychotherapy and gives examples of the use of such a room in practice.

  3. Ethical views, attitudes and reactions of Romanian medical students to the dissecting room.

    Science.gov (United States)

    Bob, M H; Popescu, Codruţa Alina; Armean, M S; Suciu, Soimita Mihaela; Buzoianu, Anca Dana

    2014-01-01

    Our objective was to evaluate the attitudes and views of first year medical students towards cadaver dissection in anatomy learning and discuss various findings in relation with ethical problems). The study was conducted at the "Iuliu Hat ieganu" University of Medicine and Pharmacy, during the academic year 2012-2013 at the end of the second semester. There were 121 first year medical students included. We developed a questionnaire to asses among other, the degree of fear, anxiety and stress in the dissection room, methods of coping, ethical aspects of dissection and hand it to the students. 34.7% of students experienced different levels of fear on exposure to the dissection room practical sessions. Many students experienced anxiety in reaction to dissection. In the first semester most students reported physical and behavioral reaction towards certain stimuli, with a decrease in the second semester. Recurring visual images of cadavers, reported by 57% of students in the first semester, dropped to 44.6% in the second semester. Students used most frequently the "rationalization and emotional detachment" as a coping method. Anatomists, most often the firsts who need to be aware of emotional and ethical issues, need to explain in detail the steps necessary for dissection and that dissection is performed with the respect of legislation, ethics and human rights.

  4. Radiation Protection Elephants in the Room

    International Nuclear Information System (INIS)

    Vetter, R. J.

    2004-01-01

    As our system of radiological protection evolves, several significant issues loom within radiation protection discussions and publications. These issues influence the nature of epidemiological and radiobiological research and the establishment of radiation protection recommendations, standards, and regulations. These issues are like the proverbial e lephants in the room . They are large, and it is unwise to ignore them. This paper discusses the impact of three young elephants as they make their presence increasingly obvious: increased cancer susceptibility from early-life exposure to radiation, terrorism and fear of radiation, and patient safety. Increased cancer susceptibility from early-life exposure to radiation is emerging as a discussion topic related to the safety of computed tomography (CT) and other medical modalities. Shortly after publication of CT dose data, manufacturers were helping to reduce doses to children by increasing flexibility for adjustment of technique factors. Also, radiation epidemiological data are being used in the development of guidance on exposure to chemical carcinogens during early life. Re-emergence of public fear of radiation has been fueled by threats of radiological dispersion devises and confusing messages about personal decontamination, emergency room acceptance or rejection of contaminated victims, and environmental clean-up. Finally, several professional publications have characterized risk of medical radiation exposure in terms of patient deaths even though epidemiological data do not support such conclusions. All three of these elephants require excellent science and sophisticated data analysis to coax them from the room. Anecdotal communications that confuse the public should be avoided. These are not the only elephants in the room, but these three are making their presence increasingly obvious. This paper discusses the need for radiation protection professionals to rely on good science in the evolution of the system of

  5. Air Distribution in Rooms with a Fan-Driven Convector

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Bindels, Rob H.W.; Michalak, Lukasz

    2007-01-01

    the acceptable conditions for the supplyJlow rate and the temperature difference for the convector system. The paper shows that the air distribution from the convector results in comfortable velocity and temperature conditions with a heat load of 210 W. This is also confirmed by the draft ratings, which in all...... coming from the dijfuser is partly controlled by the momentum flow and partly from gravity forces, where the thermal load in the room and the temperature difference between room air and supply air affect the airflow from the convector. The convector system was tested in the same test room in which many......Experiments with a fan-driven convector used for both heating and cooling are de.scribed in this paper. Only the cooling situation is considered. The convector is positioned in the upper corner ofthe room, and from there the cold air is let out through the device along the ceiling. The airflow...

  6. Novel bed integrated ventilation method for hospital patient rooms

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Melikov, Arsen Krikor; Kokora, Monika

    2014-01-01

    This study presents a novel method for advanced ventilation of hospital wards leading to improved air quality at reduced ventilation rate. The idea is to evacuate the bio-effluents generated from patients’ body by local exhaustion before being spread in the room. This concept was realized by using...... a mattress having a suction opening from which bio-effluents generated from human body are exhausted. Experiments were conducted in a full-scale two-bed hospital room mock-up, 4.7 x 5.3 x 2.6 m3 (W x L x H). Only one of the patients’ beds was equipped with the ventilated mattress. The room was air...... conditioned via mixing total volume ventilation system supplying air through a ceiling mounted diffuser. All experiments were performed at room air temperature of 23ºC. A thermal manikin was used to simulate a polluting patient on the bed equipped with the ventilated mattress. Two heated dummies were used...

  7. Evaluation of the shielding of a room for radiodiagnostic

    International Nuclear Information System (INIS)

    Padilla R, Z. P.; Acuna D, E.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    The X-ray discovery by Roentgen in 1895 and its application in diagnosis was a breakthrough in medicine. Worldwide, X-ray technique is one of the most widely used procedures in medical diagnosis. At the Mental Health Hospital of Calera Zacatecas a room has been designed as radiology room, however there is not a record of shielding characteristics. In order to determine the features of X-ray equipment that the room can host, in this work a series of calculations were carried out. Calculations were based upon the NCRP 151 recommendations and fulfilling the requirements given in the Mexican standard NOM-229-SSA1-2002. From the actual room conditions this can host a X-ray equipment without fluoroscopy, with a workload of 80 ma-min/week, with 125 k Vp as maximum operating voltage. From the actual conditions a set of recommendations, for better protection of radiation workers and public are also given. (Author)

  8. Music for All: Including young people with intellectual disability in a university environment.

    Science.gov (United States)

    Rickson, Daphne; Warren, Penny

    2017-01-01

    We investigated a continuing education course in creative music making, initiated to promote the inclusion of young people with intellectual disability in a university setting. Despite organizers' attempts to foster diversity within the student cohort, enrolments were almost exclusively from students who had intellectual disability. Being in the university environment, and in a place of higher learning, seemed to be valued by some. However, students' main focus was on group musicking in a dedicated music room rather than interacting with the wider university community. Those who did not identify as disabled believed it was important to continue to address the barriers to wider inclusion. While acknowledging the risks around mediating the social interactions of young people with intellectual disability, we argue that future courses should include activities specifically designed to bring them to classes with typical students and to the wider activities of the university.

  9. The Influence of Room Colors in A House for Its Occupants

    Directory of Open Access Journals (Sweden)

    Dila Hendrassukma

    2016-01-01

    Full Text Available Home was a place where each individual could go after doing various routine activities. Residential interior design would support the quality of life of its occupants. The majority of the population of Indonesia, especially in Jakarta, had been aware of the importance of design interior of their homes properly. However, the selection of interior elements of color that was supporting the smoothness of the activities in a room was not considered as whole. The research objective was to analyze a great color for every room in the home based on the theory and the psychology of color. This article was expected to be a guide for those who will design an interior room. The method used was qualitative method in the form of observation and study of literature. Results of the study is the choice of a suitable color that fit in any room home, such as the living room, bedroom, kitchen, and bathroom can maximize the function of the room for the occupants. 

  10. Profile of central research and application laboratory of Aǧrı İbrahim Çeçen University

    Science.gov (United States)

    Türkoǧlu, Emir Alper; Kurt, Murat; Tabay, Dilruba

    2016-04-01

    Aǧrı İbrahim Çeçen University built a central research and application laboratory (CRAL) in the east of Turkey. The CRAL possesses 7 research and analysis laboratories, 12 experts and researchers, 8 standard rooms for guest researchers, a restaurant, a conference hall, a meeting room, a prey room and a computer laboratory. The CRAL aims certain collaborations between researchers, experts, clinicians and educators in the areas of biotechnology, bioimagining, food safety & quality, omic sciences such as genomics, proteomics and metallomics. It also intends to develop sustainable solutions in agriculture and animal husbandry, promote public health quality, collect scientific knowledge and keep it for future generations, contribute scientific awareness of all stratums of society, provide consulting for small initiatives and industries. It has been collaborated several scientific foundations since 2011.

  11. Profile of central research and application laboratory of Ağrı İbrahim Çeçen University

    International Nuclear Information System (INIS)

    Türkoğlu, Emir Alper; Kurt, Murat; Tabay, Dilruba

    2016-01-01

    Ağrı İbrahim Çeçen University built a central research and application laboratory (CRAL) in the east of Turkey. The CRAL possesses 7 research and analysis laboratories, 12 experts and researchers, 8 standard rooms for guest researchers, a restaurant, a conference hall, a meeting room, a prey room and a computer laboratory. The CRAL aims certain collaborations between researchers, experts, clinicians and educators in the areas of biotechnology, bioimagining, food safety & quality, omic sciences such as genomics, proteomics and metallomics. It also intends to develop sustainable solutions in agriculture and animal husbandry, promote public health quality, collect scientific knowledge and keep it for future generations, contribute scientific awareness of all stratums of society, provide consulting for small initiatives and industries. It has been collaborated several scientific foundations since 2011.

  12. Profile of central research and application laboratory of Ağrı İbrahim Çeçen University

    Energy Technology Data Exchange (ETDEWEB)

    Türkoğlu, Emir Alper, E-mail: eaturkoglu@yandex.com [Ağrı İbrahim Çeçen University, Faculty of Pharmacy, Department of Pharmaceutical Technology, Ağrı (Turkey); Ağrı İbrahim Çeçen University, Central Research and Application Laboratory, Ağrı (Turkey); Kurt, Murat, E-mail: muratkurt60@hotmail.com; Tabay, Dilruba, E-mail: dtabay@agri.edu.tr [Ağrı İbrahim Çeçen University, Central Research and Application Laboratory, Ağrı (Turkey)

    2016-04-18

    Ağrı İbrahim Çeçen University built a central research and application laboratory (CRAL) in the east of Turkey. The CRAL possesses 7 research and analysis laboratories, 12 experts and researchers, 8 standard rooms for guest researchers, a restaurant, a conference hall, a meeting room, a prey room and a computer laboratory. The CRAL aims certain collaborations between researchers, experts, clinicians and educators in the areas of biotechnology, bioimagining, food safety & quality, omic sciences such as genomics, proteomics and metallomics. It also intends to develop sustainable solutions in agriculture and animal husbandry, promote public health quality, collect scientific knowledge and keep it for future generations, contribute scientific awareness of all stratums of society, provide consulting for small initiatives and industries. It has been collaborated several scientific foundations since 2011.

  13. Simultaneousness of room heating and ventilation air heating

    International Nuclear Information System (INIS)

    Mathisen, Hans Martin

    2006-01-01

    The report is part of NTNU-SINTEF's Smart Buildings program, Smart Energy Efficient Buildings (2002-2006), subprogram 3.1 Heating, ventilation and cooling systems. An important part of this subprogram is the development and implementation of heating distribution systems with low return temperature. A comparison has been made of the simultaneousness of room heating and ventilation air heating in six buildings. Existing measuring data with hourly measurements of effect requirements for the different purposes have been employed. Based on the measuring data the relation between the requirements for room heating and ventilation is estimated. A 'fictitious' return temperature has also been estimated. The result shows a significant variation between the buildings. For all there are short periods where the efficiency need for room heating and ventilation is equal (ml)

  14. Evaluation of an automated room decontamination device using aerosolized peracetic acid.

    Science.gov (United States)

    Mana, Thriveen S C; Sitzlar, Brett; Cadnum, Jennifer L; Jencson, Annette L; Koganti, Sreelatha; Donskey, Curtis J

    2017-03-01

    Because manual cleaning is often suboptimal, there is increasing interest in use of automated devices for room decontamination. We demonstrated that an ultrasonic room fogging system that generates submicron droplets of peracetic acid and hydrogen peroxide eliminated Clostridium difficile spores and vegetative pathogens from exposed carriers in hospital rooms and adjacent bathrooms. Published by Elsevier Inc.

  15. Reaction of Medical Students to Experiences in Dissection Room ...

    African Journals Online (AJOL)

    Conclusion: The present study findings show that smell of the dissection room, touch and fear of cadaver were the commonest cause of their symptoms experienced while study in dissection room for the majority of students. Thus, instructors are should give awareness raising education before the commencement of the ...

  16. Control console for the X-ray room

    International Nuclear Information System (INIS)

    Garcia H, J.M.; Aguilar B, M.A.; Torres B, M.A.

    1998-01-01

    It is presented the design and construction of Control console for the X-ray room of Metrology Center for ionizing radiations at National Institute of Nuclear Research (ININ). This system controls the positioning of 6 different filters for an X-ray beam. Also it controls a shutter which blockades the beam during periods established by user, these periods can be fixed from hours until tenth of second. The shutter opening periods, as well as the X-ray beam filter are establish and monitoring from a Personal computer outside of room. (Author)

  17. Room design for high-performance electron microscopy

    International Nuclear Information System (INIS)

    Muller, David A.; Kirkland, Earl J.; Thomas, Malcolm G.; Grazul, John L.; Fitting, Lena; Weyland, Matthew

    2006-01-01

    Aberration correctors correct aberrations, not instabilities. Rather, as spatial resolution improves, a microscope's sensitivity to room environment becomes more noticeable, not less. Room design is now an essential part of the microscope installation process. Previously ignorable annoyances like computer fans, desk lamps and that chiller in the service corridor now may become the limiting factors in the microscopes performance. We discuss methods to quantitatively characterize the instrument's response to magnetic, mechanical, acoustical and thermal disturbances and thus predict the limits that the environment places on imaging and spectroscopy

  18. Wind tunnel testing to predict control room atmospheric dispersion factors

    International Nuclear Information System (INIS)

    Holmquist, L.J.; Harden, P.A.; Muraida, J.E.

    1993-01-01

    Recent concerns at Palisades about control room habitability in the event of a loss-of-coolant accident have led to an extensive effort to increase control room habitability margin. The heating, ventilating and air-conditioning (HVAC) system servicing the control room has the potential for unfiltered in-leakage through its normal outside air intake louvered isolation dampers during emergency mode. The current limiting control room habitability analysis allows for 1.2 x 10 -2 m 3 /s (25 ft 3 /min) unfiltered in-leakage into the control room envelope. This leakage value was not thought to be achievable with the existing as-built configuration. Repairing the system was considered as a potential solution; however, this would be costly and could negatively affect plant operation. In addition, the system would still be required to meet the low specified unfiltered in-leakage. A second approach to this problem was to determine the atmospheric dispersion factors (x/Q's) through a wind tunnel test using a scale model of Palisades. The results of the wind tunnel testing could yield more realistic x/Q's for control room habitability than previously employed methods. Palisades selected the wind tunnel study option based on its ease of implementation, realistic results, and low cost. More importantly, the results of the study could increase the allowable unfiltered in-leakage

  19. Using a Research Simulator for Validating Control Room Modernization Concepts

    International Nuclear Information System (INIS)

    Boring, Ronald L.; Agarwal, Vivek; Persensky, Julius J.; Joe, Jeffrey C.

    2012-01-01

    The Light Water Reactor Sustainability Program is a research, development, and deployment program sponsored by the United States Department of Energy. The program is operated in close collaboration with industry research and development programs to provide the technical foundations for licensing and managing the long-term, safe, and economical operation of nuclear power plants that are currently in operation. Advanced instrumentation and control (I and C) technologies are needed to support the continued safe and reliable production of power from nuclear energy systems during sustained periods of operation up to and beyond their expected licensed lifetime. This requires that new capabilities to achieve process control be developed and eventually implemented in existing nuclear control rooms. It also requires that approaches be developed and proven to achieve sustainability of I and C systems throughout the period of extended operation. Idaho National Laboratory (INL) is working closely with nuclear utilities to develop technologies and solutions to help ensure the safe life extension of current reactors. One of the main areas of focus is control room modernization. Current analog control rooms are growing obsolete, and it is difficult for utilities to maintain them. Using its reconfigurable control room simulator adapted from a training simulator, INL serves as a neutral test bed for implementing new control room system technologies and assisting in control room modernization efforts across. (author)

  20. Using a Research Simulator for Validating Control Room Modernization Concepts

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring; Vivek Agarwal; Julius J. Persensky; Jeffrey C. Joe

    2012-05-01

    The Light Water Reactor Sustainability Program is a research, development, and deployment program sponsored by the United States Department of Energy. The program is operated in close collaboration with industry research and development programs to provide the technical foundations for licensing and managing the long-term, safe, and economical operation of nuclear power plants that are currently in operation. Advanced instrumentation and control (I&C) technologies are needed to support the continued safe and reliable production of power from nuclear energy systems during sustained periods of operation up to and beyond their expected licensed lifetime. This requires that new capabilities to achieve process control be developed and eventually implemented in existing nuclear control rooms. It also requires that approaches be developed and proven to achieve sustainability of I&C systems throughout the period of extended operation. Idaho National Laboratory (INL) is working closely with nuclear utilities to develop technologies and solutions to help ensure the safe life extension of current reactors. One of the main areas of focus is control room modernization. Current analog control rooms are growing obsolete, and it is difficult for utilities to maintain them. Using its reconfigurable control room simulator adapted from a training simulator, INL serves as a neutral test bed for implementing new control room system technologies and assisting in control room modernization efforts across.

  1. Reconstructing the Gamma-Ray Photon Optical Depth of the Universe To Z Approx. 4 from Multiwavelength Galaxy Survey Data

    Science.gov (United States)

    Helgason, Kari; Kashlinsky, Alexander

    2012-01-01

    Reconstructing the Gamma-Ray Photon Optical Depth of the Universe To Z Approx. 4fFrom Multiwavelength Galaxy Survey Data We reconstruct the gamma-ray opacity of the universe out to z approx. photons already at z approx. < 0.2 and reaching tau approx 10 at z = 1. Comparing with the currently available Fermi/LAT gamma-ray burst and blazar data shows that there is room for significant emissions originating in the first stars era.

  2. Performance and Effectiveness of Portable Air Cleaners in an Office Room

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian

    2015-01-01

    Nowadays, many people work in an office environment. Air pollutants, including particles and gases, are generated by humans and by different devices that are used in offices. Pollutants can also enter an office room with the air supplied from outdoors. It has been established that air pollutants...... and particles in an office room. The particle removal effectiveness of the technologies was also determined in order to clarify their ability to remove UFPs (ultrafine particles) in the office room. The tested five air cleaning technologies are non-thermal plasma, corona discharge ionizer, portable air purifier......, electrostatic fibrous filter and three-dimensional fibrous filter. The interior surfaces of the office room emit low levels of volatile organic compounds, since the office room has not been refurbished for about two decades. The results showed that the particle removal effectiveness of the technologies...

  3. Auralization of airborne sound insulation including the influence of source room

    DEFF Research Database (Denmark)

    Rindel, Jens Holger

    2006-01-01

    The paper describes a simple and acoustically accurate method for the auralization of airborne sound insulation between two rooms by means of a room acoustic simulation software (ODEON). The method makes use of a frequency independent transparency of the transmitting surface combined...... with a frequency dependent power setting of the source in the source room. The acoustic properties in terms of volume and reverberation time as well as the area of the transmitting surface are all included in the simulation. The user only has to select the position of the source in the source room and the receiver...... of the transmitting surface is used for the simulation of sound transmission. Also the reduced clarity of the auralization due to the reverberance of the source room is inherent in the method. Currently the method is restricted to transmission loss data in octave bands....

  4. FRAMEWORK AND APPLICATION FOR MODELING CONTROL ROOM CREW PERFORMANCE AT NUCLEAR POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L Boring; David I Gertman; Tuan Q Tran; Brian F Gore

    2008-09-01

    This paper summarizes an emerging project regarding the utilization of high-fidelity MIDAS simulations for visualizing and modeling control room crew performance at nuclear power plants. The key envisioned uses for MIDAS-based control room simulations are: (i) the estimation of human error associated with advanced control room equipment and configurations, (ii) the investigative determination of contributory cognitive factors for risk significant scenarios involving control room operating crews, and (iii) the certification of reduced staffing levels in advanced control rooms. It is proposed that MIDAS serves as a key component for the effective modeling of cognition, elements of situation awareness, and risk associated with human performance in next generation control rooms.

  5. FRAMEWORK AND APPLICATION FOR MODELING CONTROL ROOM CREW PERFORMANCE AT NUCLEAR POWER PLANTS

    International Nuclear Information System (INIS)

    Ronald L Boring; David I Gertman; Tuan Q Tran; Brian F Gore

    2008-01-01

    This paper summarizes an emerging project regarding the utilization of high-fidelity MIDAS simulations for visualizing and modeling control room crew performance at nuclear power plants. The key envisioned uses for MIDAS-based control room simulations are: (1) the estimation of human error associated with advanced control room equipment and configurations, (2) the investigative determination of contributory cognitive factors for risk significant scenarios involving control room operating crews, and (3) the certification of reduced staffing levels in advanced control rooms. It is proposed that MIDAS serves as a key component for the effective modeling of cognition, elements of situation awareness, and risk associated with human performance in next generation control rooms

  6. Comorbidity in Emergency Room: the Psychiatrist’s Perspective

    OpenAIRE

    Alice Luís

    2013-01-01

    The author puts forward some considerations about the psychiatric practice in the emergency room of a general hospital. Clinical practice in the emergency room should be highlighted by collaborative work between several medical subspecialities, in- cluding internal medicine and neurology. This is particularly true for patients with comorbidity in order to provide quality of care. Finally, the author reviews several clinical cases and suggests guidelines for their management.

  7. Airflow and Temperature Distribution in Rooms with Displacement Ventilation

    DEFF Research Database (Denmark)

    Jacobsen, T. V.

    This thesis deals with air flow and temperature distribution in a room ventilated by the displacement principle. The characteristic features of the ventilation system are treated in the whole room but main emphasis is laid on the analysis of the stratified flow region in front of the inlet device....... After a prefatory description of the background and the fundamentals of displacement ventilation the objectives of the current study are specified. The subsequent sections describe the measurements of velocity and temperature profiles carried out in a full scale test room. Based on experimental data...... of measured data is of crucial importance. Qualitatively satisfactory results do not ensure quantitative agreement....

  8. Contaminant Distribution Around Persons in Rooms Ventilated by Displacement Ventilation

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter V.

    An optimal design of the ventilation system needs a proper prediction of the velocity, temperature and contaminant distribution in the room. Traditionally this is done either by the use of simplified models or by a somewhat more comprehensive CFD-simulation. Common to both methods is usually...... the lack of consideration for the persons present in the room. This paper deals with some of the effects of persons present in a displacement ventilated room, especially the effect on the contaminant distribution....

  9. Fungal DNA in hotel rooms in Europe and Asia--associations with latitude, precipitation, building data, room characteristics and hotel ranking.

    Science.gov (United States)

    Norbäck, Dan; Cai, Gui-Hong

    2011-10-01

    There is little information on the indoor environment in hotels. Analysis of fungal DNA by quantitative PCR (qPCR) is a new method which can detect general and specific sequences. Dust was collected through swab sampling of door frames in 69 hotel rooms in 20 countries in Europe and Asia (2007-2009). Five sequences were detected by qPCR: total fungal DNA, Aspergillus and Penicillium DNA (Asp/Pen DNA), Aspergillus versicolor (A. versicolor DNA), Stachybotrys chartarum (S. chartarum DNA) and Streptomyces spp. (Streptomyces DNA). Associations were analysed by multiple linear regression. Total fungal DNA (GM = 1.08 × 10(8) cell equivalents m(-2); GSD = 6.36) and Asp/Pen DNA (GM = 1.79 × 10(7) cell equivalents m(-2); GSD = 10.12) were detected in all rooms. A. versicolor DNA, S. chartarum DNA and Streptomyces DNA were detected in 84%, 28% and 47% of the samples. In total, 20% of the rooms had observed dampness/mould, and 30% had odour. Low latitude (range 1.5-64.2 degrees) was a predictor of Asp/Pen DNA. Seaside location, lack of mechanical ventilation, and dampness or mould were other predictors of total fungal DNA and Asp/Pen DNA. Hotel ranking (Trip Advisor) or self-rated quality of the interior of the hotel room was a predictor of total fungal DNA, A. versicolor DNA and Streptomyces DNA. Odour was a predictor of S. chartarum DNA. In conclusion, fungal DNA in swab samples from hotel rooms was related to latitude, seaside location, ventilation, visible dampness and indoor mould growth. Hotels in tropical areas may have 10-100 times higher levels of common moulds such as Aspergillus and Penicillium species, as compared to a temperate climate zone.

  10. Low frequency sound reproduction in irregular rooms using CABS (Control Acoustic Bass System)

    DEFF Research Database (Denmark)

    Celestinos, Adrian; Nielsen, Sofus Birkedal

    2011-01-01

    of an irregular room model using the FDTD (Finite Difference Time Domain) method has been presented. CABS has been simulated in the irregular room model. Measurements of CABS in a real irregular room have been performed. The performance of CABS was affected by the irregular shape of the room due to the corner...

  11. Dormancy breaking in Mauritia flexuosa seeds by using mechanical scarification and soaking = Superação de dormência em sementes de buriti por meio da escarificação mecânica e embebição

    Directory of Open Access Journals (Sweden)

    Alexsander Seleguini

    2012-12-01

    casualizado, no esquema fatorial 2 x 3 + 1, com cinco repetições. Foram testadas sementes com e sem escarificação, combinadas com métodos de embebição (sementes não embebidas e sementes embebidas por 30 dias, com e sem renovação diária de água, além de um tratamento adicional, onde as sementes foram escarificadas após a embebição por 30 dias. Foi avaliada a emergência de plântulas aos 46, 66, 86, 106, 126 e 146 dias após a semeadura (DAS, bem como o índice de velocidade de emergência (46 e 146 DAS e os componentes de crescimento (146 DAS. Os resultados foram submetidos à análise de variância (Teste F e as médias comparadas pelo teste Tukey, a 5%. Concluiu-se que as sementes de buriti apresentam dormência tegumentar. A escarificaçãode sementes aumenta a velocidade de emergência, entretanto, contribui para o aumento na taxa de mortalidade das sementes. A embebição de sementes não escarificadas por 30 dias, com renovação diária de água, melhora o potencial germinativo das sementes. A escarificação mecânica, sem ou após a embebição das sementes em água, aumenta a mortalidade de plântulas de buritizeiro, não sendo, portanto, um método adequado para a superação de dormência.

  12. Have it your way. A modular approach to custom compact control rooms

    International Nuclear Information System (INIS)

    Harmon, Daryl; Scarola, Ken

    2003-01-01

    In spite of the recent lack of growth in the nuclear power industry, a transition is taking place to compact main control rooms as the design of choice for power generating facilities. This is evident in the design and construction of new facilities, including Advanced Light Water Reactors such as the Korean Shin Kori 3 and 4 units, as well as Generation IV reactors. Also, compact control rooms are increasingly preferred for the modernization of current generation plants. This shift reflects that compact control rooms combine cost savings through equipment reduction and standardization with operability improvements through increased functionality and flexibility and improved presentation. Though compact control rooms feature significantly fewer Human Machine Interface (HMI) devices than their conventional counterparts, customers still require a wide variety of different configurations to accommodate their individual operations philosophies, cultural norms, licensing regulations and physical constraints. To meet this need, Westinghouse Electric Company has developed an innovative, modular approach to designing compact control rooms for nuclear power plants. This approach features a small set of standard HMI devices serving as building blocks for all compact control room functions. The building blocks include qualified and non-safety video devices for implementing displays, alarms, multi-channel soft controls, computerized procedures, etc. These building blocks can be used for (1) large screen overview displays, (2) console-based control and monitoring and (3) HMI devices for conventional, benchboard-style control panels. Their modular design allows these building blocks to be arranged in various physical configurations to meet a wide variety of customer's control room preferences and constraints. For example, a compact control room could use the qualified building blocks (1) to configure a dedicated safety panel independent of the normal operational consoles, or (2

  13. Radioactivity of radon and its short-lived decay products in room air, 2

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Katoh, Takao

    1983-01-01

    In the reactor room of the Kyoto University Research Reactor Institute, the measurements of radon (Rn) and its short-lived decay products (Rn-Dts) were carried out under ventilated and non-ventilated conditions. The indoor activities were equal to outdoor ones under ventilated condition and those activities increased till about 10 times of outdoors under non-ventilated condition. We attempted to explain these results on a basis of a simple model. The calculations were performed taking into account: (1) supply of Rn and Rn-Dts from outdoor, (2) the emanation rate of Rn from the wall materials of building, (3) the removal rate of Rn-Dts by ventilation and wall deposition, and (4) the attachment rate of unattached atom to aerosols. In addition, natural ventilation were considered during periods without artificial ventilation. (author)

  14. Hotels Make Room for Fitness.

    Science.gov (United States)

    Koszuta, Laurie Einstein

    1986-01-01

    Hotels, in hopes of gaining a competitive edge, are offering workout rooms, exercise equipment, fitness trails, and jogging tracks, but no standards have been set for safety of the facilities or staff preparedness in exercise screening, equipment use, injury prevention, or first aid. (MT)

  15. Modernisation of Radiation Monitoring Room as a Part of Slovenian Emergency Response Centre

    International Nuclear Information System (INIS)

    Sarvari, A.; Mitic, D.

    2003-01-01

    In the year 2002 the Slovenian Nuclear Safety Administration (SNSA) moved to the new premises therefore it had to rearrange some of its rooms for the emergency situation. SNSA does not operate with a dedicated Emergency Response Centre (ERC), instead of it the SNSA has to rearrange the existing rooms in case of an emergency. Modernisation of the equipment, with the help of government of the United Kingdom of Great Britain and Northern Ireland, for the emergency situation was carried out, especially in the monitoring room. The radiation monitoring system, which is placed in the monitoring room, continuously collects, processes and archives the incoming data of exposure to radiation and meteorological parameters on the Slovenian territory (A model national emergency response plan for radiological accidents, IAEA, Vienna, 1993. IAEA-TECDOC-718). In the emergency situation the monitoring room transforms into the room for the Dose Assessment Group (DAG), which is part of ERC (IAEA emergency response network, IAEA, Vienna, 2000, EPR-ERNET (2000)). The modernisation of monitoring room and within the DAG room with new equipment and its purpose is described in this article. Modernisation of the monitoring room and the room for DAG showed to be inevitably needed. Modernisation of the monitoring room has brought the SNSA a sophisticated and reliable system of controlling the external exposure to radiation on the Slovenian territory. The equipment, especially the equipment for the use in the emergency situation, brought novelties for the Dose Assessment Group. The group has now better and easier control of radiation situation in case of an accident. In overall this modernisation has put the Slovenian Nuclear Safety Administration a step forward in having a dedicated Emergency Response Centre, since it does not need to rearrange the room for the Dose Assessment Group. (author)

  16. Room Thermostat with Servo Controlled by PIC Microcontroller

    Directory of Open Access Journals (Sweden)

    Jan Skapa

    2013-01-01

    Full Text Available This paper describes the design of room thermostat with Microchip PIC microcontroller. Thermostat is designated for two-pipe heating system. The microprocessor controls thermostatic valve via electric actuator with mechanical gear unit. The room thermostat uses for its activity measurements of air temperature in the room and calorimetric measurement of heat, which is served to the radiator. These features predestinate it mainly for underfloor heating regulation. The thermostat is designed to work in a network. Communication with heating system's central control unit is proceeded via RS485 bus with proprietary communication protocol. If the communication failure occurs the thermostat is able to work separately. The system uses its own real time clock circuit and memory with heating programs. These programs are able to cover the whole heating season. The method of position discontinuous PSD control is used in this equipment.

  17. Problems related to design and construction of industrial radiography exposure room - an experience

    International Nuclear Information System (INIS)

    Siti Madiha Muhammad Amir; Mohd Khairi Mohd Said; Abdul Nassir Ibrahim; Ab Razak Hamzah

    2009-01-01

    In Non-Destructive Testing (NDT), especially in radiography method, inspections of components are executed either on-site or in-house. For in-house inspections, work must be performed in a specially constructed exposure room. The design of the exposure room must be according to specific requirements described in various documents related to radiation safety. Stringent requirements specified for the exposure room is for the purpose of ensuring the safety of public and radiation workers. These requirements are never compromised. One of the AELB requirements that need to be complied is that the permissible dose limit anywhere outside the room must be less than 0.25 mR/hr. In designing and constructing the exposure room, many factors must be taken into account such as shielding thickness, density of shielding, thickness of lead door, the roof design of the exposure room and many more. This paper highlights problems encountered and the considerations taken to design and construct the exposure room so that the exposure room will comply with the permissible dose limit set by the regulatory body. (Author)

  18. THE PERFORMANCE OF SERVQUAL TO MEASURE SERVICE QUALITY IN PRIVATE UNIVERSITY

    Directory of Open Access Journals (Sweden)

    Leonnard

    2018-03-01

    Full Text Available The increasing number of educational services has caused a high competition in this industry. In Indonesia, the number of private universities is the highest compared to state universities and other forms of higher education institutions. Ability to predict factors that are important in providing educational services to achieve student satisfaction and make them loyal to the university is highly necessary. In this study, we investigated the main factors of service quality that affect student satisfaction and loyalty by collecting data from 319 students from London School of Public Relation in Jakarta. Structural equation modeling (SEM was employed to analyze the data through AMOS 24 statistical package. The findings indicated that the main factors influencing student satisfaction in private university are tangible and reliability consisting of: 1 comfortable lecture rooms, 2 adequate library facilities, 3 neat staff appearance, 4 non-discriminatory treatments provided by staff and lecturers, 5 high ability and knowledge provided by staffs and lecturers, and 6 appropriate academic services provided by the university. Student satisfaction with these factors would indirectly lead to loyalty to the university. Finally, service quality measurement through SERVQUAL was redundant as a model to measure the effect of service quality in educational service.

  19. HABIT, Toxic and Radioactive Release Hazards in Reactor Control Room

    International Nuclear Information System (INIS)

    Stage, S.A.

    2005-01-01

    1 - Description of program or function: HABIT is a package of computer codes designed to be used for the evaluation of control room habitability in the event of an accidental release of toxic chemicals or radioactive materials. 2 - Methods: Given information about the design of a nuclear power plant, a scenario for the release of toxic or radionuclides, and information about the air flows and protection systems of the control room, HABIT can be used to estimate the chemical exposure or radiological dose to control room personnel

  20. GOTHIC Simulation of APR1400 Auxiliary Charging Pump room heat up

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Hui-Un; Heo, Sun [KHNP, Daejeon (Korea, Republic of)

    2014-10-15

    As a part of the Advanced Power Reactor 1400 (APR1400) U. S. Nuclear Regulatory Commission Design Certification (NRC DC) project, we have been investigating Auxiliary Charging Pump (ACP) room heat up. With reference to the design specification of the ACP room, we determined input information and developed a GOTHIC model of the APR1400 ACP room. This calculation model is described herein, and representative results from the calculation are presented as well. The results of the present paper are used to determine the integrity of ACP operating in the accident. APR 1400 GOTHIC model was developed for ACP room heat up calculation. Calculation results confirm that door opening is cooling the room properly. It is found that the difference due to the surface option of heat conductors is insignificant. Based on this result, further studies should be performed to confirm integrity of ACP.

  1. Effects of Room Color on Mirror-Tracing by Junior High School Girls.

    Science.gov (United States)

    Bross, Cindy; Jackson, Karen

    1981-01-01

    Girls in Grades 7, 8, and 9 practiced mirror-tracing in a neutral colored room to a criterion before being tested in their preferred or nonpreferred colored rooms. The errors decreased significantly in the preferred room, while the time to complete changed minimally. (Author)

  2. Neutron absorbing room temperature vulcanizable silicone rubber compositions

    International Nuclear Information System (INIS)

    Zoch, H.L.

    1979-01-01

    A neutron absorbing composition is described and consists of a one-component room temperature vulcanizable silicone rubber composition or a two-component room temperature vulcanizable silicone rubber composition in which the composition contains from 25 to 300 parts by weight based on the base silanol or vinyl containing diorganopolysiloxane polymer of a boron compound or boron powder as the neutron absorbing ingredient. An especially useful boron compound in this application is boron carbide. 20 claims

  3. Design and methods of a social network isolation study for reducing respiratory infection transmission: The eX-FLU cluster randomized trial.

    Science.gov (United States)

    Aiello, Allison E; Simanek, Amanda M; Eisenberg, Marisa C; Walsh, Alison R; Davis, Brian; Volz, Erik; Cheng, Caroline; Rainey, Jeanette J; Uzicanin, Amra; Gao, Hongjiang; Osgood, Nathaniel; Knowles, Dylan; Stanley, Kevin; Tarter, Kara; Monto, Arnold S

    2016-06-01

    Social networks are increasingly recognized as important points of intervention, yet relatively few intervention studies of respiratory infection transmission have utilized a network design. Here we describe the design, methods, and social network structure of a randomized intervention for isolating respiratory infection cases in a university setting over a 10-week period. 590 students in six residence halls enrolled in the eX-FLU study during a chain-referral recruitment process from September 2012-January 2013. Of these, 262 joined as "seed" participants, who nominated their social contacts to join the study, of which 328 "nominees" enrolled. Participants were cluster-randomized by 117 residence halls. Participants were asked to respond to weekly surveys on health behaviors, social interactions, and influenza-like illness (ILI) symptoms. Participants were randomized to either a 3-Day dorm room isolation intervention or a control group (no isolation) upon illness onset. ILI cases reported on their isolation behavior during illness and provided throat and nasal swab specimens at onset, day-three, and day-six of illness. A subsample of individuals (N=103) participated in a sub-study using a novel smartphone application, iEpi, which collected sensor and contextually-dependent survey data on social interactions. Within the social network, participants were significantly positively assortative by intervention group, enrollment type, residence hall, iEpi participation, age, gender, race, and alcohol use (all Pisolation from social networks in a university setting. These data provide an unparalleled opportunity to address questions about isolation and infection transmission, as well as insights into social networks and behaviors among college-aged students. Several important lessons were learned over the course of this project, including feasible isolation durations, the need for extensive organizational efforts, as well as the need for specialized programmers and server

  4. Key facilitators and best practices of hotel-style room service in hospitals.

    Science.gov (United States)

    Sheehan-Smith, Lisa

    2006-04-01

    This qualitative study sought to identify the features, advantages, and disadvantages of hotel-style room service; the barriers to, and facilitators for, implementing the process; and "best practices." The study took place in four heterogeneous hospitals. Participants included hospital administrators, managers, and room-service employees. Data-collection methods included semi-structured interviews, observations, and document analysis. Common features of hotel-style room service were meal delivery within 30 to 45 minutes, a restaurant-style menu, procedures to feed ineligible patients, tray assembly on demand, scripting, and waitstaff uniforms for room-service employees. The major barrier to implementing room service was obtaining nursing support. The key facilitators were the hospital's service-oriented culture, using a multidisciplinary planning team, engaging nursing departments early in the planning stages, and intense customer-service training of room-service employees. The overwhelming advantage was patients' control over their food choices. The main disadvantage was cost. Initial best practices in hotel-style room service include: (a) taking a multidisciplinary team approach for developing and implementing the process, (b) customer-service training, (c) using a customer-driven menu, (d) wearing waitstaff uniforms, and (e) using carts with airpots for dispensing hot beverages.

  5. Not Your Run-of-the-Mill Art-Room Stools

    Science.gov (United States)

    Chrzanowski, Rose-Ann C.

    2010-01-01

    An art room should be a garden of visual stimulation, born of creativity, inquiry, critical thinking and intellectual conversation--and a little collaboration is not a bad thing either! When the author unpacked the new stools for her art room at the high school, she envisioned something more beautiful than the brown masonite circles that…

  6. Respiratory viral RNA on toys in pediatric office waiting rooms.

    Science.gov (United States)

    Pappas, Diane E; Hendley, J Owen; Schwartz, Richard H

    2010-02-01

    Toys in pediatric office waiting rooms may be fomites for transmission of viruses. Eighteen samples were taken from office objects on 3 occasions. Samples were tested for presence of picornavirus (either rhinovirus or enterovirus) on all 3 sample days; in addition, January samples were tested for respiratory syncytial virus and March samples were tested for influenza A and B. In addition, 15 samples were obtained from the sick waiting room before and after cleaning. Polymerase chain reaction was used to detect picornavirus, respiratory syncytial virus, and influenza A or B virus. Finally, 20 samples were obtained from the fingers of a researcher after handling different toys in the sick waiting room, and samples were then obtained from all the same toys; all samples were tested for picornavirus by polymerase chain reaction. Viral RNA was detected on 11 of 52 (21%) of toys sampled. Ten of the positives were picornavirus; 1 was influenza B virus. Three (30%) of 10 toys from the new toy bag, 6 of 30 (20%) in the sick child waiting room, and 2 of 12 (17%) in the well child waiting room were positive. Six (40%) of 15 toys in the sick waiting room were positive for picornaviral RNA before cleaning; after cleaning, 4 (27%) of 15 were positive in spite of the fact that RNA was removed from 4 of 6 of the original positives. Three (15%) of 20 toys in the sick waiting room were positive for picornaviral RNA, but RNA was not transferred to the fingers of the investigator who handled these toys. About 20% of the objects in a pediatric office may be contaminated with respiratory viral RNA, most commonly picornavirus RNA. Cleaning with a disinfectant cloth was only modestly effective in removing the viral RNA from the surfaces of toys, but transfer of picornaviral RNA from toys to fingers was inefficient.

  7. Game-based training environment for nuclear plant control room

    International Nuclear Information System (INIS)

    Hung Tamin; Sun Tienlung; Yang Chihwei; Yang Lichen; Cheng Tsungchieh; Wang Jyhgang

    2011-01-01

    Nuclear power plant's safety is very important problem. In this very conscientious environment if operator has a little mistake, they may threaten with many people influence their safety. Therefore, operating training of control room is very important. However, the operator training is in limited space and time. Each operator must go to simulative control room do some training. If we can let each trainee having more time to do training and does not go to simulative control room. It may have some advantages for trainee. Moreover, in the traditional training ways, each operator may through the video, teaching manual or through the experienced instructor to learn the knowledge. This training way may let operator feel bored and stressful. So, in this paper aims, we hope utilizing virtual reality technology developing a game-based virtual training environment of control room. Finally, we will use presence questionnaire evaluating realism and feasibility of our virtual training environment. Expecting this initial concept of game-based virtual training environment can attract trainees having more learning motivation to do training in off-hour. (author)

  8. CONVERSATIONS -- AND NEGOTIATED INTERACTION -- IN TEXT AND VOICE CHAT ROOMS

    Directory of Open Access Journals (Sweden)

    Kevin Jepson

    2005-09-01

    Full Text Available Despite the expanded use of the Internet for language learning and practice, little attention if any has been given to the quality of interaction among English L2 speakers in conversational text or voice chat rooms. This study explored the patterns of repair moves in synchronous non-native speaker (NNS text chat rooms in comparison to voice chat rooms on the Internet. The following questions were posed: (a Which types of repair moves occur in text and voice chats; and (b what are the differences, if any, between the repair moves in text chats and voice chats when time is held constant? Repair moves made by anonymous NNSs in 10, 5-minute, synchronous chat room sessions (5 text-chat sessions, 5 voice-chat sessions were counted and analyzed using chi-square with alpha set at .05. Significant differences were found between the higher number of total repair moves made in voice chats and the smaller number in text chats. Qualitative data analysis showed that repair work in voice chats was often pronunciation-related. The study includes discussion that may affect teachers' and learners' considerations of the value of NNS chat room interaction for second language development.

  9. Measurement Of Lead Equivalent Thickness For Irradiation Room: An Analysis

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Azuhar Ripin; Husaini Salleh; Mohd Khairusalih Mohd Zin; Muhammad Jamal Muhd Isa; Mohd Faizal Abdul Rahman

    2014-01-01

    The Malaysian Ministry of Health (MOH) has established that the irradiation room must have a sufficient thickness of shielding to ensure that requirements for the purpose of radiation protection of patients, employees and the public are met. This paper presents a technique using americium-241 source to test and verify the integrity of the shielding thickness in term of lead equivalent for irradiation room at health clinics own by MOH. Results of measurement of 8 irradiation rooms conducted in 2014 were analyzed for this presentation. Technical comparison of the attenuation of gamma rays from Am-241 source through the walls of the irradiation room and pieces of lead were used to assess the lead equivalent thickness of the walls. Results showed that almost all the irradiation rooms tested meet the requirements of the Ministry of Health and is suitable for the installation of the intended diagnostic X-ray apparatus. Some specific positions such as door knobs and locks, electrical plug sockets were identified with potential to not met the required lead equivalent thickness hence may contribute to higher radiation exposure to workers and the public. (author)

  10. Evaluation of Sound Quality, Boominess and Boxiness in Small Rooms

    DEFF Research Database (Denmark)

    Weisser, Adam; Rindel, Jens Holger

    2006-01-01

    ratings. The classical bass ratio definitions showed poor correlation with all subjective ratings. The overall sound quality ratings gave different results for speech and music. For speech the preferred mean RT should be as low as possible, whereas for music there was found a preferred range between 0......The acoustics of small rooms has been studied with emphasis on sound quality, boominess and boxiness when the rooms are used for speech or music. Seven rooms with very different characteristics have been used for the study. Subjective listening tests were made using binaural recordings...... of reproduced speech and music. The test results were compared with a large number of objective acoustic parameters based on the frequency-dependent reverberation times measured in the rooms. This has led to the proposal of three new acoustic parameters, which have shown high correlation with the subjective...

  11. SRF Clean Rooms and Cryomodule Assembly

    Data.gov (United States)

    Federal Laboratory Consortium — Three primary cleanroom facilities used for the SRF cryomodule production program are available. All 3 clean rooms have class 10 and class 100 areas. The largest is...

  12. Microalgal Mass Culture Room Harvest Records

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The microalgal mass culture room, housed at the NOAA Fisheries' Milford CT laboratory, provides research grade microalgae (phytoplankton) to in-house and...

  13. Transient natural ventilation of a room with a distributed heat source

    Science.gov (United States)

    Fitzgerald, Shaun D.; Woods, Andrew W.

    We report on an experimental and theoretical study of the transient flows which develop as a naturally ventilated room adjusts from one temperature to another. We focus on a room heated from below by a uniform heat source, with both high- and low-level ventilation openings. Depending on the initial temperature of the room relative to (i) the final equilibrium temperature and (ii) the exterior temperature, three different modes of ventilation may develop. First, if the room temperature lies between the exterior and the equilibrium temperature, the interior remains well-mixed and gradually heats up to the equilibrium temperature. Secondly, if the room is initially warmer than the equilibrium temperature, then a thermal stratification develops in which the upper layer of originally hot air is displaced upwards by a lower layer of relatively cool inflowing air. At the interface, some mixing occurs owing to the effects of penetrative convection. Thirdly, if the room is initially cooler than the exterior, then on opening the vents, the original air is displaced downwards and a layer of ambient air deepens from above. As this lower layer drains, it is eventually heated to the ambient temperature, and is then able to mix into the overlying layer of external air, and the room becomes well-mixed. For each case, we present new laboratory experiments and compare these with some new quantitative models of the transient flows. We conclude by considering the implications of our work for natural ventilation of large auditoria.

  14. Testing of Method for Assessing of Room Thermal Stability

    Directory of Open Access Journals (Sweden)

    Charvátová Hana

    2017-01-01

    Full Text Available The paper presents the interim results of our research on the developing methodological procedure which could be used for assessment of a thermal stability of buildings with regards to its thermal accumulative parameters. The principle of testing is based on a combination of computer simulation of cooled room model developed in COMSOL Multiphysics software and on theoretical calculations with respect to compliance with valid European and Czech technical standards used in building industry and architecture under conditions obtained by real measurement for the room to be tested. The presented example shows the effect of the heataccumulation properties of the outside wall insulation materials on the course of the cooling room for winter conditions.

  15. Comparison of test protocols for standard room/corner tests

    Science.gov (United States)

    R. H. White; M. A. Dietenberger; H. Tran; O. Grexa; L. Richardson; K. Sumathipala; M. Janssens

    1998-01-01

    As part of international efforts to evaluate alternative reaction-to-fire tests, several series of room/comer tests have been conducted. This paper reviews the overall results of related projects in which different test protocols for standard room/corner tests were used. Differences in the test protocols involved two options for the ignition burner scenario and whether...

  16. Multiple Scattering of Gamma Radiation in a Spherical Concrete Wall Room

    Energy Technology Data Exchange (ETDEWEB)

    Leimdoerfer, M

    1962-12-15

    The Monte Carlo method has been applied for the calculation of the energy flux of scattered gamma radiation in a spherical room surrounded by an infinitely thick spherical wall and with a point source at the centre. Source energies were I, 2, 4, 6, and 10 MeV. The main investigation was carried out at a room radius of 500 cm but, for the 1 MeV source, the influence of varying the room radius down to 1 cm was analysed. The results contain energy distributions of the first four successive reflection components at the centre of the room and at the wall surface, as well as spatial distributions of the successive energy flux components. The neglect of reflection contributions of order five and higher was estimated to introduce an error of less than 0. 2 % of the total scattered energy flux. An analytical approximation is shown to produce a useful and easily applicable method of predicting the amount of scattered radiation in a spherical room.

  17. Multiple Scattering of Gamma Radiation in a Spherical Concrete Wall Room

    International Nuclear Information System (INIS)

    Leimdoerfer, M.

    1962-12-01

    The Monte Carlo method has been applied for the calculation of the energy flux of scattered gamma radiation in a spherical room surrounded by an infinitely thick spherical wall and with a point source at the centre. Source energies were I, 2, 4, 6, and 10 MeV. The main investigation was carried out at a room radius of 500 cm but, for the 1 MeV source, the influence of varying the room radius down to 1 cm was analysed. The results contain energy distributions of the first four successive reflection components at the centre of the room and at the wall surface, as well as spatial distributions of the successive energy flux components. The neglect of reflection contributions of order five and higher was estimated to introduce an error of less than 0. 2 % of the total scattered energy flux. An analytical approximation is shown to produce a useful and easily applicable method of predicting the amount of scattered radiation in a spherical room

  18. Controlling the selective formation of calcium sulfate polymorphs at room temperature.

    Science.gov (United States)

    Tritschler, Ulrich; Van Driessche, Alexander E S; Kempter, Andreas; Kellermeier, Matthias; Cölfen, Helmut

    2015-03-23

    Calcium sulfate is a naturally abundant and technologically important mineral with a broad scope of applications. However, controlling CaSO4 polymorphism and, with it, its final material properties still represents a major challenge, and to date there is no universal method for the selective production of the different hydrated and anhydrous forms under mild conditions. Herein we report the first successful synthesis of pure anhydrite from solution at room temperature. We precipitated calcium sulfate in alcoholic media at low water contents. Moreover, by adjusting the amount of water in the syntheses, we can switch between the distinct polymorphs and fine-tune the outcome of the reaction, yielding either any desired CaSO4 phase in pure state or binary mixtures with predefined compositions. This concept provides full control over phase selection in CaSO4 mineralization and may allow for the targeted fabrication of corresponding materials for use in various areas. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. [Role-specific targets and teamwork in the operating room].

    Science.gov (United States)

    Hoeper, K; Kriependorf, M; Felix, C; Nyhuis, P; Tecklenburg, A

    2017-12-01

    The primary goal of a surgical team is the successful performance of an operation on a patien; however, this primary goal can show discrepancies from the goals of individual team members. The main causes for differences of interests can be variations in subjective preferences and organizational differences. Subjective preferences are due to the values held by those involved. These values are of an intrinsic nature and therefore difficult to change. Another reason for individual goals is that hospitals and universities are professional bureaucracies. Experts working in professional bureaucracies are known to identify themselves to a greater extent with their respective profession than with their institution; however, teams in the operating room (OR) have to work together in multidisciplinary teams. The main goal of this analysis is to document role-specific targets and motivations within teams. This was a case study at a university hospital with 40 operating rooms. The data collection resulted from the three pillars of the goal documentation instrument, which includes expert interviews, a utility analysis and card placement as a basis for communicative validation. The results were analyzed with a systematic method as a qualitative content analysis. The four-pillar success model, which maps aspects of a successful hospital, was used as a deductive coding scheme. The four pillars represent the level of medical quality (process, structure and outcome quality), economy and efficiency, client satisfaction (patients and referring physicians) and employee satisfaction. At a university hospital an additional focus is on research and teaching. In addition to the four pillar success model as a deductive coding scheme, an inductive coding scheme was introduced. Approximately 10% of the employees from each professional group (surgeons, anesthesiologists, OR nurses, nurse anesthetists) were interviewed resulting in 65 interviews overall. The interviews were conducted

  20. Predicting the Room Air Temperature of the Containment Spray Pump Room for the Loss of HVAC Accidents

    International Nuclear Information System (INIS)

    Yoon, Churl; Park, Jin Hee; Lim, Ho Gon; Han, Sang Hoon

    2007-01-01

    In PSA Models, the HVAC system is essential for the various vital mitigation safety systems operating during a mission time. So far, the unavailability of the safety system when the HVAC system is unavailable, has been applied conservatively or optimistically based on operating experience and expert judgment, so the total core damage frequency could be unrealistic. In this paper, we performed a heat up calculation for the Containment Spray Pump Room at Kori 3 and 4 Units using a CFD code to estimate the operability of the CS pump and its support systems in the pump room under the situation of a loss of the HVAC. The result of this calculation could be applied the PSA Model for Risk Informed Regulation for Kori Units 3 and 4

  1. Wind pressure testing of tornado safe room components made from wood

    Science.gov (United States)

    Robert Falk; Deepak Shrestha

    2016-01-01

    To evaluate the ability of a wood tornado safe room to resist wind pressures produced by a tornado, two safe room com-ponents were tested for wind pressure strength. A tornado safe room ceiling panel and door were static-pressure-tested according to ASTM E 330 using a vacuum test system. Re-sults indicate that the panels had load capacities from 2.4 to 3.5 times that...

  2. Replacement of the Advanced Test Reactor control room

    International Nuclear Information System (INIS)

    Durney, J.L.; Klingler, W.B.

    1989-01-01

    The control room for the Advanced Test Reactor has been replaced to provide modern equipment utilizing current standards and meeting the current human factors requirements. The control room was designed in the early 1960 era and had not been significantly upgraded since the initial installation. The replacement did not change any of the safety circuits or equipment but did result in replacement of some of the recorders that display information from the safety systems. The replacement was completed in concert with the replacement of the control room simulator which provided important feedback on the design. The design successfully incorporates computer-based systems into the display of the plant variables. This improved design provides the operator with more information in a more usable form than was provided by the original design. The replacement was successfully completed within the scheduled time thereby minimizing the down time for the reactor. 1 fig., 1 tab

  3. Replacement of the Advanced Test Reactor control room

    International Nuclear Information System (INIS)

    Durney, J.L.; Klingler, W.B.

    1990-01-01

    The control room for the Advanced Test Reactor has been replaced to provide modern equipment utilizing current standards and meeting the current human factors requirements. The control room was designed in the early 1960 era and had not been significantly upgraded since the initial installation. The replacement did not change any of the safety circuits or equipment but did result in replacement of some of the recorders that display information from the safety systems. The replacement was completed in concert with the replacement of the control room simulator which provided important feedback on the design. The design successfully incorporates computer-based systems into the display of the plant variables. This improved design provides the operator with more information in a more usable form than was provided by the original design. The replacement was successfully completed within the scheduled time thereby minimizing the down time for the reactor

  4. Room Temperature Memory for Few Photon Polarization Qubits

    Science.gov (United States)

    Kupchak, Connor; Mittiga, Thomas; Jordan, Bertus; Nazami, Mehdi; Nolleke, Christian; Figueroa, Eden

    2014-05-01

    We have developed a room temperature quantum memory device based on Electromagnetically Induced Transparency capable of reliably storing and retrieving polarization qubits on the few photon level. Our system is realized in a vapor of 87Rb atoms utilizing a Λ-type energy level scheme. We create a dual-rail storage scheme mediated by an intense control field to allow storage and retrieval of any arbitrary polarization state. Upon retrieval, we employ a filtering system to sufficiently remove the strong pump field, and subject retrieved light states to polarization tomography. To date, our system has produced signal-to-noise ratios near unity with a memory fidelity of >80 % using coherent state qubits containing four photons on average. Our results thus demonstrate the feasibility of room temperature systems for the storage of single-photon-level photonic qubits. Such room temperature systems will be attractive for future long distance quantum communication schemes.

  5. Thermalization of monoenergetic neutrons in a concrete room

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Mercado, G.A. [UAZ, A.P. 336, 98000 Zacatecas (Mexico); Iniguez, M.P.; Martin M, A. [Universidad de Valladolid, (Spain)

    2006-07-01

    The thermalization of neutrons from monoenergetic neutron sources in a concrete room has been studied. During calibration of neutron detectors it is mandatory to make corrections due to neutron scattering produced by the room walls, therefore this factor must be known in advance. The scattered neutrons are thermalized and produce a neutron field that is directly proportional to source strength and inversely proportional to room total wall-surfaces, the proportional coefficient has been calculated for neutrons whose energy goes from 1 eV to 20 MeV. This coefficient was calculated using Monte Carlo methods for 150, 200 and 300 cm-radius spherical cavity, where monoenergetic neutrons were located at the center, along the spherical cavity radius neutron spectra were calculated at several source-to-detector distances inside the cavity. The obtained coefficient is almost three times larger than the factor normally utilized. (Author)

  6. User evaluation of an innovative digital reading room.

    Science.gov (United States)

    Hugine, Akilah; Guerlain, Stephanie; Hedge, Alan

    2012-06-01

    Reading room design can have a major impact on radiologists' health, productivity, and accuracy in reading. Several factors must be taken into account in order to optimize the work environment for radiologists. Further, with the advancement in imaging technology, clinicians now have the ability to view and see digital exams without having to interact with radiologists. However, it is important to design components that encourage and enhance interactions between clinicians and radiologists to increase patient safety, and to combine physician and radiologist expertise. The present study evaluates alternative workstations in a real-world testbed space, using qualitative data (users' perspectives) to measure satisfaction with the lighting, ergonomics, furniture, collaborative spaces, and radiologist workstations. In addition, we consider the impact of the added collaboration components of the future reading room design, by utilizing user evaluation surveys to devise baseline satisfaction data regarding the innovative reading room environment.

  7. Microbial Load in Septic and Aseptic Procedure Rooms.

    Science.gov (United States)

    Harnoss, Julian-Camill; Assadian, Ojan; Diener, Markus Karl; Müller, Thomas; Baguhl, Romy; Dettenkofer, Markus; Scheerer, Lukas; Kohlmann, Thomas; Heidecke, Claus-Dieter; Gessner, Stephan; Büchler, Markus Wolfgang; Kramer, Axel

    2017-07-10

    Highly effective measures to prevent surgical wound infections have been established over the last two decades. We studied whether the strict separation of septic and aseptic procedure rooms is still necessary. In an exploratory, prospective observational study, the microbial concentration in an operating room without a room ventilating system (RVS) was analyzed during 16 septic and 14 aseptic operations with the aid of an air sampler (50 cm and 1 m from the operative field) and sedimentation plates (1 m from the operative field, and contact culture on the walls). The means and standard deviations of the microbial loads were compared with the aid of GEE models (generalized estimation equations). In the comparison of septic and aseptic operations, no relevant differences were found with respect to the overall microbial concentration in the room air (401.7 ± 176.3 versus 388.2 ± 178.3 CFU/m 3 ; p = 0.692 [CFU, colony-forming units]) or sedimentation 1 m from the operative field (45.3 ± 22.0 versus 48.7 ± 18.5 CFU/m 2 /min; p = 0.603) and on the walls (35.7 ± 43.7 versus 29.0 ± 49.4 CFU/m 2 /min; p = 0.685). The only relevant differences between the microbial spectra associated with the two types of procedure were a small amount of sedimentation of Escherichia coli and Enterococcus faecalis in septic operations, and of staphylococcus aureus and pseudomonas stutzeri in aseptic operations, up to 30 minutes after the end of the procedure. These data do not suggest that septic and aseptic procedure rooms need to be separated. In interpreting the findings, one should recall that the study was not planned as an equivalence or non-inferiority study. Wherever patient safety is concerned, high-level safety concepts should only be demoted to lower levels if new and convincing evidence becomes available.

  8. The protection of radioactive nuclide and nursing management in DSA room

    International Nuclear Information System (INIS)

    Zhang Guimin

    2009-01-01

    Objective: To discuss the protection of radioactive nuclide and nursing management in DSA room. Methods: The clinical state of the protection of radioactive 131 I nuclide and nursing management in DSA room was retrospectively summarized. Results: The standard management for the protection of radioactive nuclide in DSA room was established. The main management schemas included the management of personnel, the management of professional skills and, specialty, the management of radioactive drugs and abandoned odds and ends, preoperative health education, etc. Conclusion: The standard management can ensure that the patients get a good radionuclide therapy in DSA room, and, at the same time, the working environment can be effectively protected and the professional nursing staff can be well trained. (authors)

  9. Simulation of a room for neutron instrument calibration at LCR/UERJ

    International Nuclear Information System (INIS)

    Medeiros, M.P.C.; Estrada, J.J.S.; Gomes, R.G.; Santos, R.F.G.; Leite, S.P.; Alves, C.F.E.; Rebello, W.F.; Almeida, C.E. de

    2013-01-01

    In this work the MCNPX code was used to design a calibrating room for neutron detectors to be implemented in the Laboratorio de Ciencias Radiologicas of UERJ. The calibration room containing a neutron irradiator with a 241 Am-Be source, a linear positioning system, radiation detectors and a shadow cone was modeled. The ambient dose equivalent rate, ııı ∗ ı10ı, in adjacent to the calibration room areas, as well as neutron scattering caused by the room itself were calculated. Using an occupancy factor of 1/16 for all adjacent areas, 3.8 cm of 5% borated polyethylene or 5.5 cm of concrete for shielding is enough to satisfy radiation safety requirements. (author)

  10. Respiratory management of the preterm newborn in the delivery room

    Directory of Open Access Journals (Sweden)

    Abdel-Hady H

    2012-05-01

    Full Text Available Hesham Abdel-Hady, Nehad NasefNeonatal Intensive Care Unit, Mansoura University Children's Hospital, Mansoura, EgyptAbstract: The survival of preterm infants has improved significantly during the past several decades. However, bronchopulmonary dysplasia remains a major morbidity. Preterm infants have both structural and functional lung immaturity compared with term infants, making them more likely to require resuscitation and more vulnerable to developing bronchopulmonary dysplasia. Interventions in the delivery room may affect short-term and long-term outcomes for preterm infants. The paradigm of resuscitation of preterm infants has been changing over the past decade from being interventional and invasive to be observational and gentle. Recent developments in respiratory management of preterm infants in the delivery room include oxygen supplementation and monitoring, alveolar recruitment techniques, noninvasive ventilation, new surfactant preparations, and new techniques for administration of surfactant. Providing nasal continuous positive airway pressure (CPAP rather than intubating has been identified as a potentially better practice. Experimental studies have demonstrated that early application of nasal CPAP is protective for the preterm lung and brain compared with mechanical ventilation. Several observational studies have suggested that early nasal CPAP and avoiding intubation leads to reduced oxygen requirements, intubation rates, duration of mechanical ventilation, and may decrease rates of bronchopulmonary dysplasia. Multicenter, randomized controlled trials support the use of nasal CPAP as a primary strategy in preterm babies with respiratory distress syndrome. This approach leads to a reduction in the number of infants who are intubated and given surfactant without an impact on bronchopulmonary dysplasia rates. On the other hand, half of the infants enrolled in these studies failed nasal CPAP treatment. New techniques for surfactant

  11. ENERGY STAR Certified Room Air Conditioners

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 4.0 ENERGY STAR Program Requirements for Room Air Conditioners that are effective as of...

  12. Factors Affecting Acoustics and Speech Intelligibility in the Operating Room: Size Matters.

    Science.gov (United States)

    McNeer, Richard R; Bennett, Christopher L; Horn, Danielle Bodzin; Dudaryk, Roman

    2017-06-01

    Noise in health care settings has increased since 1960 and represents a significant source of dissatisfaction among staff and patients and risk to patient safety. Operating rooms (ORs) in which effective communication is crucial are particularly noisy. Speech intelligibility is impacted by noise, room architecture, and acoustics. For example, sound reverberation time (RT60) increases with room size, which can negatively impact intelligibility, while room objects are hypothesized to have the opposite effect. We explored these relationships by investigating room construction and acoustics of the surgical suites at our institution. We studied our ORs during times of nonuse. Room dimensions were measured to calculate room volumes (VR). Room content was assessed by estimating size and assigning items into 5 volume categories to arrive at an adjusted room content volume (VC) metric. Psychoacoustic analyses were performed by playing sweep tones from a speaker and recording the impulse responses (ie, resulting sound fields) from 3 locations in each room. The recordings were used to calculate 6 psychoacoustic indices of intelligibility. Multiple linear regression was performed using VR and VC as predictor variables and each intelligibility index as an outcome variable. A total of 40 ORs were studied. The surgical suites were characterized by a large degree of construction and surface finish heterogeneity and varied in size from 71.2 to 196.4 m (average VR = 131.1 [34.2] m). An insignificant correlation was observed between VR and VC (Pearson correlation = 0.223, P = .166). Multiple linear regression model fits and β coefficients for VR were highly significant for each of the intelligibility indices and were best for RT60 (R = 0.666, F(2, 37) = 39.9, P the size and contents of an OR can predict a range of psychoacoustic indices of speech intelligibility. Specifically, increasing OR size correlated with worse speech intelligibility, while increasing amounts of OR contents

  13. Four days of life university after Islamic revolution: From April 19 to April 22, 1980

    Directory of Open Access Journals (Sweden)

    M. Rezaie

    2017-03-01

    Full Text Available After 1979 Islamic revolution, from April 20 to 22, 1980 universities in Tehran, Tabriz and some other cities, experienced an outstanding political juncture. Active collegiate political groups were compelled to surrender their rooms and offices, and leave the universities’ campus. Accordingly, universities and cities were the scene of bloody clashes. As a matter of fact, university as the fortress of freedom, resistance and revolution against Pahlavi was about to change its revolutionary identity and to adapt new role of an engaged proponent of Islamic regime. Concerning to Badiou’s concept of empty space and Delousian Rhizomatic analysis, we study related news and pictures of related newspapers. Concludingly, we demonstrate the set of relations in which Islamic university renovates. Also, we illustrate how the universities, on the one hand, acted as an agent and a mechanism for de-centering the revolutionary characteristic, and remaining this “Holy Place”, in Ayatollah Khomeini’s word, as a permanent Islamic partisan of new born political regime, simultanouly.

  14. Draft audit report, human factors engineering control room design review: Saint Lucie Nuclear Power Plant, Unit No. 2

    International Nuclear Information System (INIS)

    Peterson, L.R.; Lappa, D.A.; Moore, J.W.

    1981-01-01

    A human factors engineering preliminary design review of the Saint Lucie Unit 2 control room was performed at the site on August 3 through August 7, 1981. This design review was carried out by a team from the Human Factors Engineering Branch, Division of Human Factors Safety. This report was prepared on the basis of the HFEB's review of the applicant's Preliminary Design Assessment and the human factors engineering design review/audit performed at the site. The review team included human factors consultants from BioTechnology, Inc., Falls Church, Virginia, and from Lawrence Livermore National Laboratory (University of California), Livermore, California

  15. Game theory: applications for surgeons and the operating room environment.

    Science.gov (United States)

    McFadden, David W; Tsai, Mitchell; Kadry, Bassam; Souba, Wiley W

    2012-11-01

    Game theory is an economic system of strategic behavior, often referred to as the "theory of social situations." Very little has been written in the medical literature about game theory or its applications, yet the practice of surgery and the operating room environment clearly involves multiple social situations with both cooperative and non-cooperative behaviors. A comprehensive review was performed of the medical literature on game theory and its medical applications. Definitive resources on the subject were also examined and applied to surgery and the operating room whenever possible. Applications of game theory and its proposed dilemmas abound in the practicing surgeon's world, especially in the operating room environment. The surgeon with a basic understanding of game theory principles is better prepared for understanding and navigating the complex Operating Room system and optimizing cooperative behaviors for the benefit all stakeholders. Copyright © 2012 Mosby, Inc. All rights reserved.

  16. The radiation protection environmental assesment for 60Co irradiation room

    International Nuclear Information System (INIS)

    Zheng Meiyang; Jin Guohua; Shen Genfang

    2010-01-01

    60 Co source is applied in the process such as sterilizing agricultural products in irradiation room of some Academy of Agricultural Sciences, which is very effective in agricultural applications. However, 60 Co is highly toxic, once the leak, the consequences would be disastrous. So it is necessary to summarize the radiation protection and safety evaluation of the irradiation room indoor and outdoor, to ensure the health and lives of the staff and the surrounding population. The radiation detectors monitor six points around the irradiation room. Results show that design of irradiation room of Academy of Agricultural Sciences are mostly safe and reliable, regardless of the source in working condition. And consequences also show 60 Co source in the normal operating will not put adverse effects on the surrounding environment. In addition, the outer radiation protective measures are also outlined, in view of 60 Co own identity. (authors)

  17. Influence of disturbances on bacteria level in an operating room

    DEFF Research Database (Denmark)

    Brohus, Henrik; Hyldig, Mikkel; Kamper, Simon

    2008-01-01

    In operating rooms great effort is manifested to reduce the bacteria level in order to decrease the risk of infections. The main source of bacteria is the staff and the patient, thus, the resulting bacteria concentration is roughly speaking a combination of the ventilation system and the emission...... from the occupants. This study investigates the influence of two main disturbances in an operating room namely the door opening during the operation and the activity level of the staff. It is found that the frequent door opening in this case does not cause significant transport of air from outside...... the operating room to the wound area of the patient. However, a significant influence of the activity level on the bacteria emission and concentration is found. Counting the number of persons in an operating room to estimate the bacteria source strength is not sufficient, the corresponding activity level must...

  18. Evaluation of the Onset of Flashover in Room Fire Experiments

    DEFF Research Database (Denmark)

    Poulsen, Annemarie; Jomaas, Grunde; Bwalya, Alex

    2013-01-01

    Two series of full scale room fire tests comprising 16 experiments are used for a study of the onset of flashover. The fire loads were varied and represented seven different commercial applications and two non-combustible linings with significantly different thermal inertia were used. The test...... results showed that by lowering the thermal inertia and thereby lowering the heat loss from the room and at the same time increasing the thermal feedback, a thermal runaway occurred before significant fire spread; but only for objects composed of a mixture of plastic/rubber/textiles and wood....../celluloses. In these cases the onset of thermal runaway was found to occur at room temperatures in the range 300C to 420C, supporting that the room temperature at the onset of thermal runaway is strongly dependent on the thermal inertia. It also shows that the onset of thermal runaway cannot in all cases implicitly...

  19. Dose estimation of the THOR BNCT treatment room

    International Nuclear Information System (INIS)

    Hsu, F.Y.; Liu, H.M.; Yu, C.C.; Huang, Y.H.; Tsai, H.N.

    2006-01-01

    BNCT beam of Tsing Hua Open-pool Reactor (THOR) was designed and constructed since 1998. A treatment room for the newly modified THOR BNCT beam was constructed for the next clinical-stage trials in 2004. Dose distribution in a patient (or a phantom) is important as irradiated with the BNCT beam. The dose distributions for different type of radiations such as neutron and photons in the treatment room are strongly becoming the index or reference of success for a BNCT facility. An ART head phantom was placed in front of the THOR BNCT beam port and was irradiated. In each section of the head phantom, numbers of small holes are inside and separated uniformly. Dual detector: TLD-600 and TLD-700 chips were placed inside these holes within the phantom to distinct doses of neutron and photon. Besides, Dual-TLD chips were latticed placed in the horizontal plane of beam central axis, in the treatment room to estimate the spatial dose distribution of neutron and photon. Gold foils were assisted in TLD dose calibrations. Neutron and photon dose distributions in phantom and spatial dose distributions in the THOR BNCT treatment room were both estimated in this work. Testing and improvement in THOR BNCT beam were continuative during these years. Results of this work could be the reference and be helpful for the further clinical trials in nearly future. (author)

  20. MEMS and Nano-Technology Clean Room

    Data.gov (United States)

    Federal Laboratory Consortium — The MEMS and Nano-Technology Clean Room is a state-of-the-art, 800 square foot, Class 1000-capable facility used for development of micro and sub-micro scale sensors...