WorldWideScience

Sample records for unit water purifier

  1. Purified water quality study

    Spinka, H.; Jackowski, P.

    2000-01-01

    Argonne National Laboratory (HEP) is examining the use of purified water for the detection medium in cosmic ray sensors. These sensors are to be deployed in a remote location in Argentina. The purpose of this study is to provide information and preliminary analysis of available water treatment options and associated costs. This information, along with the technical requirements of the sensors, will allow the project team to determine the required water quality to meet the overall project goals

  2. Removal of Inorganic, Microbial, and Particulate Contaminants from a Fresh Surface Water: Village Marine Tec. Expeditionary Unit Water Purifier, Generation 1

    The Village Marine Tec. Generation 1 Expeditionary Unit Water Purifier (EUWP) is a mobile skid-mounted system employing ultrafiltration (UF) and reverse osmosis (RO) to produce drinking water from a variety of different water quality sources. The UF components were evaluated to t...

  3. Mine water purify from radium

    Lebecka, J.

    1996-01-01

    The article describes purification of radium containing water in coal mines. Author concludes that water purification is relatively simple and effective way to decrease environmental pollution caused by coal mining. The amount of radium disposed with type A radium water has been significantly decreased. The results of investigations show that it will be soon possible to purify also type B radium water. Article compares the amounts of radium disposed by coal mines in 1990, 1995 and forecast for 2000

  4. Home drinking-water purifiers

    Pizzichini, Massimo; Pozio, Alfonso; Russo, Claudio

    2005-01-01

    To salve the widespread problem of contaminated drinking water, home purifiers are now sold in Italy as well as other countries. This article describes how these devices work, how safe they are to use and how safe the water they produce, in the broad context of regulations on drinking water and mineral water. A new device being developed by ENEA to treat municipal water and ground water could provide greater chemical and bacteriological safety. However, the appearance of these new systems makes it necessary to update existing regulations [it

  5. Removal of Dissolved Salts and Particulate Contaminants from Seawater: Village Marine Tec., Expeditionary Unit Water Purifier, Generation 1

    The EUWP was developed to treat challenging water sources with variable turbidity, chemical contamination, and very high total dissolved solids (TDS), including seawater, during emergency situations when other water treatment facilities are incapacitated. The EUWP components incl...

  6. 21 CFR 880.6710 - Medical ultraviolet water purifier.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical ultraviolet water purifier. 880.6710... Miscellaneous Devices § 880.6710 Medical ultraviolet water purifier. (a) Identification. A medical ultraviolet water purifier is a device intended for medical purposes that is used to destroy bacteria in water by...

  7. Removal of Inorganic, Microbial, and Particulate Contaminants from Secondary Treated Wastewater - Village Marine Tec. Expeditionary Unit Water Purifier, Generation 1 at Gallup, NM

    The EUWP was developed to treat challenging water sources with variable turbidity, chemical contamination, and very high total dissolved solids (TDS) including seawater, during emergency situations when other water treatment facilities are incapacitated. The EUWP components are ...

  8. Cooling performance of R510A in domestic water purifiers

    Park, Ki Jung; Lee, Yo Han; Jung, Dong Soo

    2010-01-01

    Cooling performance of R510A is examined both numerically and experimentally in an effort to replace HFC134a in the refrigeration system of domestic water purifiers. Although the use of HFC134a is currently dominant, it is being phased out in Europe and most developed countries due to its high potential contribution to global warming. To solve this problem, cycle simulation and experimental measurements are conducted with a new refrigerant mixture of 88%RE170/12%R600a using actual domestic water purifiers. This mixture has been recently numbered and listed as R510A by ASHRAE. Test results show that, due to the small internal volume of the refrigeration system of the domestic water purifiers, system performance with R510A is greatly influenced by the amount of charge. With the optimum charge amount of 20 to 21 g, approximately 50% that of HFC134a, the energy consumption of R510A is 22.3% lower than that of HFC134a. The compressor discharge temperature of R510A is 3.7 .deg. C lower than that of HFC134a at the optimum charge. Overall, R510A, a new, long term, and environmentally safe refrigerant, is a good alternative for HFC134a. Furthermore, it requires only minor changes in the refrigeration system of the domestic water purifiers

  9. High-level water purifying technology. Kodo josui shori gijutsu

    Tsugura, H; Tsukiashi, K [Meidensha Corp., Tokyo (Japan)

    1993-07-01

    Research and development have been carried out on a high-level water purifying system using ozone and activated charcoals to supply drinking water free of carcinogenic matters and odors. This system comprises a system to utilize ozone by using silent discharge and oxygen enriching device, and a living organism/activated charcoal treatment system. The latter system utilizes living organisms deposited on activated charcoal surfaces to remove polluting substances including ammonia. The treatment experimenting equipment comprises an ozone generating system, an ozone treating column, an activated charcoal treating column, an ozone/activated charcoal control device, and a water amount and quality measuring system. An experiment was carried out using an experimental plant with a capacity of 20 m[sup 3]/day on water taken from the sedimentation process at an actual water purifying plant. As a result, trihalomethane formation potential was removed at about 40% in the ozone treatment, and at 70% in the whole treatment combining the ozone and living organism/activated charcoal treatments. For parameterization of palatability of water, a method is being studied that utilizes nuclear magnetic resonance to investigate degrees of water cluster. The method is regarded promising. 1 ref., 4 figs.

  10. Analysis of cavitation effect for water purifier using electrolysis

    Shin, Dong Ho; Ko, Han Seo; Lee, Seung Ho

    2015-11-01

    Water is a limited and vital resource, so it should not be wasted by pollution. A development of new water purification technology is urgent nowadays since the original and biological treatments are not sufficient. The microbubble-aided method was investigated for removal of algal in this study since it overcomes demerits of the existing purification technologies. Thus, the cavitation effect in a venturi-type tube using the electrolysis was analyzed. Ruthenium-coated titanium plates were used as electrodes. Optimum electrode interval and applied power were determined for the electrolysis. Then, the optimized electrodes were installed in the venturi-type tube for generating cavitation. The cavitation effect could be enhanced without any byproduct by the bubbly flow induced by the electrolysis. The optimum mass flow rate and current were determined for the cavitation with the electrolysis. Finally, the visualization techniques were used to count the cell number of algal and microbubbles for the confirmation of the performance. As a result, the energy saving and high efficient water purifier was fabricated in this study. This work was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Korean government (MEST) (No. 2013R1A2A2A01068653).

  11. Method and device for feeding purified water to a pressure vessel

    Hirato, Miharu.

    1982-01-01

    Purpose: To prevent thermal wear at the junction of feedwater pipes and purified water pipes, as well as maintain the function of the purified water feeding system by stopping the introduction of purified water to the heated water feeding system and introducing purified water to the recycling water system upon transient operation or start-up. Constitution: Since a feedwater heater does not function well during transient operation or upon start-up, the temperature of heated water flowing through the feedwater pipe is reduced to produce a temperature difference relative to the set temperature for the purified water feeding system. The temperature difference is detected by a temperature sensor and, when it arrives at a predetermined difference, an operation valve is switched to interrupt the feed of the purified water to the heated water feeding system and it is sent to a water recycling system. Then, the purified water is sent from the water recycling system by way of the discharge portion to the inside of a pressure vessel. Thus, since only the heated water flows to the junction between the cleaned water pipes and the heated water pipes, neither shocks are generated nor the performance of the purified water feeding system is impaired. (Moriyama, K.)

  12. Optimum design of water supply purifying station in living section of a uranium mine

    Li Jianjun; Zhang Yu

    2012-01-01

    A design of water supply purifying station in living section of a uranium mine was optimized, and appropriate technique and equipment were chosen based on the raw water quality characteristic, water consumption and change, landform of construction field, etc. After the engineering finished, the circulation is steady-going, the quality of treated water fulfills water standards for drinking water quality. (authors)

  13. [Toxicologic evaluation of purified municipal and industrial waste water].

    Prokopov, V A; Tolstopiatova, G V; Byshovets, T F; Andrienko, L G; Martyshchenko, N V; Nadvornaia, Zh N; Poviĭchuk, E R; Teteneva, I A

    1993-07-01

    Analysis of waters sewage in Kiev and of waste water of a textile and se wing enterprise in Chernigov has shown that treatment by biological method and with activated carbon was fairely efficient in toxicity reduction.

  14. Virus removal efficiency of Cambodian ceramic pot water purifiers.

    Salsali, Hamidreza; McBean, Edward; Brunsting, Joseph

    2011-06-01

    Virus removal efficiency is described for three types of silver-impregnated, ceramic water filters (CWFs) produced in Cambodia. The tests were completed using freshly scrubbed filters and de-ionized (DI) water as an evaluation of the removal efficiency of the virus in isolation with no other interacting water quality variables. Removal efficiencies between 0.21 and 0.45 log are evidenced, which is significantly lower than results obtained in testing of similar filters by other investigators utilizing surface or rain water and a less frequent cleaning regime. Other experiments generally found virus removal efficiencies greater than 1.0 log. This difference may be because of the association of viruses with suspended solids, and subsequent removal of these solids during filtration. Variability in virus removal efficiencies between pots of the same manufacturer, and observed flow rates outside the manufacturer's specifications, suggest tighter quality control and consistency may be needed during production.

  15. Effect of ultrasonic pretreatment on purified water disinfection

    Simon Andreu, P.; Lardin Mifsut, C.; Vergara Romero, L.; Polo Canas, P. M.; Perez Sanchez, P.; Rancano Perez, A.

    2009-01-01

    Due to the importance of a suitable water disinfection in order to insure a pollutant effect minimization against environment, this work has been carried out to determine how can affect an ultrasonic pre-treatment upon disinfection step. It has been confirmed the ultrasonic disintegration of bacterial cells in treated water and disinfectant power of treatment by itself, which is not enough to be used as a single method in water disinfection. It has also been proved that from a technical and economical point of view the combination of UV and ultrasound improves the UV treatment performance. Finally, it has been detected that an ultrasonic pre-treatment increases chlorination effectiveness, however the high cost in this combination makes it unfeasible of industrial scale. (Author) 6 refs

  16. Water detritiation processing of JET purified waste water using the TRENTA facility at Tritium Laboratory Karlsruhe

    Michling, R., E-mail: robert.michling@kit.edu; Bekris, N.; Cristescu, I.; Lohr, N.; Plusczyk, C.; Welte, S.; Wendel, J.

    2013-10-15

    Highlights: • Operation of a water detritiation facility under optimized conditions for high detritiation performances. • Improvement of operational procedures to process tritiated waste water. • Handling and reduction of tritiated waste water to achieve enriched low volume tritiated water for sufficient storage. • Demonstration of the efficient availability of the TRENTA WDS facility for technical scale operation. -- Abstract: A Water Detritiation System (WDS) is required for any Fusion machine in order to process tritiated waste water, which is accumulated in various subsystems during operation and maintenance. Regarding the European procurement packages for the ITER tritium fuel cycle, the WDS test facility TRENTA applying the Combined Electrolysis Catalytic Exchange (CECE) process was developed, installed and is currently in operation at the Tritium Laboratory Karlsruhe (TLK). Besides the on-going R and D work for the design of ITER WDS, the current status of the TRENTA facility provides the option to utilize the WDS for processing tritiated water. Therefore, in the framework of the EFDA JET Fusion Technology Work Programme 2011, the TLK was able to offer the capability on a representative scale to process tritiated water, which was produced during normal operation at JET. The task should demonstrate the availability of the CECE process to handle and detritiate the water in terms of tritium enrichment and volume reduction. The operational program comprised the processing of purified tritiated water from JET, with a total volume of 180 l and an activity of 74 GBq. The paper will give an introduction to the TRENTA WDS facility and an overview of the operational procedure regarding tritiated water reduction. Data concerning required operation time, decontamination and enrichment performances and different operating procedures will be presented as well. Finally, a preliminary study on a technical implementation of processing the entire stock of JET

  17. Water detritiation processing of JET purified waste water using the TRENTA facility at Tritium Laboratory Karlsruhe

    Michling, R.; Bekris, N.; Cristescu, I.; Lohr, N.; Plusczyk, C.; Welte, S.; Wendel, J.

    2013-01-01

    Highlights: • Operation of a water detritiation facility under optimized conditions for high detritiation performances. • Improvement of operational procedures to process tritiated waste water. • Handling and reduction of tritiated waste water to achieve enriched low volume tritiated water for sufficient storage. • Demonstration of the efficient availability of the TRENTA WDS facility for technical scale operation. -- Abstract: A Water Detritiation System (WDS) is required for any Fusion machine in order to process tritiated waste water, which is accumulated in various subsystems during operation and maintenance. Regarding the European procurement packages for the ITER tritium fuel cycle, the WDS test facility TRENTA applying the Combined Electrolysis Catalytic Exchange (CECE) process was developed, installed and is currently in operation at the Tritium Laboratory Karlsruhe (TLK). Besides the on-going R and D work for the design of ITER WDS, the current status of the TRENTA facility provides the option to utilize the WDS for processing tritiated water. Therefore, in the framework of the EFDA JET Fusion Technology Work Programme 2011, the TLK was able to offer the capability on a representative scale to process tritiated water, which was produced during normal operation at JET. The task should demonstrate the availability of the CECE process to handle and detritiate the water in terms of tritium enrichment and volume reduction. The operational program comprised the processing of purified tritiated water from JET, with a total volume of 180 l and an activity of 74 GBq. The paper will give an introduction to the TRENTA WDS facility and an overview of the operational procedure regarding tritiated water reduction. Data concerning required operation time, decontamination and enrichment performances and different operating procedures will be presented as well. Finally, a preliminary study on a technical implementation of processing the entire stock of JET

  18. Rheological properties of purified illite clays in glycerol/water suspensions

    Dusenkova, I.; Malers, J.; Berzina-Cimdina, L.

    2015-04-01

    There are many studies about rheological properties of clay-water suspensions, but no published investigations about clay-glycerol suspensions. In this work apparent viscosity of previously purified illite containing clay fraction clay minerals were almost totally removed by centrifugation. All obtained suspensions behaved as shear-thinning fluids with multiple times higher viscosity than pure glycerol/water solutions. Reduction of clay fraction concentration by 5% decreased the apparent viscosity of 50% glycerol/water suspensions approximately 5 times. There was basically no difference in apparent viscosity between all four 50% glycerol/water suspensions, but in 90% glycerol/water suspensions samples from Iecava deposit showed slightly higher apparent viscosity, which could be affected by the particle size distribution.

  19. Removal efficiency of water purifier and adsorbent for iodine, cesium, strontium, barium and zirconium in drinking water.

    Sato, Itaru; Kudo, Hiroaki; Tsuda, Shuji

    2011-01-01

    The severe incident of Fukushima Daiichi Nuclear Power Station has caused radioactive contamination of environment including drinking water. Radioactive iodine, cesium, strontium, barium and zirconium are hazardous fission products because of the high yield and/or relatively long half-life. In the present study, 4 pot-type water purifiers and several adsorbents were examined for the removal effects on these elements from drinking water. Iodide, iodate, cesium and barium were removed by all water purifiers with efficiencies about 85%, 40%, 75-90% and higher than 85%, respectively. These efficiencies lasted for 200 l, which is near the recommended limits for use of filter cartridges, without decay. Strontium was removed with initial efficiencies from 70% to 100%, but the efficiencies were slightly decreased by use. Zirconium was removed by two models, but hardly removed by the other models. Synthetic zeolite A4 efficiently removed cesium, strontium and barium, but had no effect on iodine and zirconium. Natural zeolite, mordenite, removed cesium with an efficiency as high as zeolite A4, but the removal efficiencies for strontium and barium were far less than those of zeolite A4. Activated carbon had little removal effects on these elements. In case of radioactive contamination of tap water, water purifiers may be available for convenient decontamination of drinking water in the home.

  20. Development of a water purifier for radioactive cesium removal from contaminated natural water by radiation-induced graft polymerization

    Seko, Noriaki; Hoshina, Hiroyuki; Kasai, Noboru; Shibata, Takuya; Saiki, Seiichi; Ueki, Yuji

    2018-02-01

    Six years after the Fukushima-nuclear accident, the dissolved radioactive cesium (Cs) is now hardly detected in environmental natural waters. These natural waters are directly used as source of drinking and domestic waters in disaster-stricken areas in Fukushima. However, the possibility that some radioactive Cs adsorbed on soil or leaves will contaminate these natural waters during heavy rains or typhoon is always present. In order for the returning residents to live with peace of mind, it is important to demonstrate the safety of the domestic waters that they will use for their daily life. For this purpose, we have synthesized a material for selective removal of radioactive Cs by introducing ammonium 12-molybdophosphate (AMP) onto polyethylene nonwoven fabric through radiation-induced emulsion graft polymerization technique. Water purifiers filled with the grafted Cs adsorbent were installed in selected houses in Fukushima. The capability of the grafted adsorbent to remove Cs from domestic waters was evaluated for a whole year. The results showed that the tap water filtered through the developed water purifier contained no radioactive Cs, signifying the very effective adsorption performance of the developed grafted adsorbent. From several demonstrations, we have commercialized the water purifier named "KranCsair®". Furthermore, we have also developed a method for the mass production of the grafted nonwoven fabric. Using a 30 L grafting reactor, it was possible to produce the grafted nonwoven fabric with a suitable range of degree of grafting. When an irradiated roll of nonwoven trunk fabric with a length of 10 m and a width of 30 cm was set in the reactor filled with glycidyl methacrylate (GMA), AMP, Tween 80 monomer emulsion solution at 40 °C for 1 h, the difference of Dgs in the length and the width on roll of fabrics was negligible.

  1. A Method of Effective Quarry Water Purifying Using Artificial Filtering Arrays

    Tyulenev, M.; Garina, E.; Khoreshok, A.; Litvin, O.; Litvin, Y.; Maliukhina, E.

    2017-01-01

    The development of open pit mining in the large coal basins of Russia and other countries increases their negative impact on the environment. Along with the damage of land and air pollution by dust and combustion gases of blasting, coal pits have a significant negative impact on water resources. Polluted quarry water worsens the ecological situation on a much larger area than covered by air pollution and land damage. This significantly worsens the conditions of people living in cities and towns located near the coal pits, and complicates the subsequent restoration of the environment, irreversibly destroying the nature. Therefore, the research of quarry wastewater purifying is becoming an important mater for scholars of technical colleges and universities in the regions with developing open-pit mining. This paper describes the method of determining the basic parameters of the artificial filtering arrays formed on coal pits of Kuzbass (Western Siberia, Russia), and gives recommendations on its application.

  2. The effect of purified sewage discharge from a sewage treatment plant on the physicochemical state of water in the receiver

    Kanownik Włodzimierz

    2016-09-01

    Full Text Available The paper presents changes in the contents of physicochemical indices of the Sudół stream water caused by a discharge of purified municipal sewage from a small mechanical-biological treatment plant with throughput of 300 m3·d−1 and a population equivalent (p.e. – 1,250 people. The discharge of purified sewage caused a worsening of the stream water quality. Most of the studied indices values increased in water below the treatment plant. Almost a 100-fold increase in ammonium nitrogen, 17-fold increase in phosphate concentrations and 12-fold raise in BOD5 concentrations were registered. Due to high values of these indices, the water physicochemical state was below good. Statistical analysis revealed a considerable effect of the purified sewage discharge on the stream water physicochemical state. A statistically significant increase in 10 indices values (BOD5, COD-Mn, EC, TDS, Cl−, Na+, K+, PO43−, N-NH4+ and N-NO2 as well as significant decline in the degree of water saturation with oxygen were noted below the sewage treatment plant. On the other hand, no statistically significant differences between the water indices values were registered between the measurement points localised 150 and 1,000 m below the purified sewage discharge. It evidences a slow process of the stream water self-purification caused by an excessive loading with pollutants originating from the purified sewage discharge.

  3. An Artificial Channel Experiment for Purifying Drainage Water Containing Arsenic by Using Eleocharis acicularis

    Okazaki, Kenji; Yamazaki, Shusaku; Kurahashi, Toshiyuki; Sakakibara, Masayuki

    2017-06-01

    This paper reports the results of an artificial channel experiment in which water containing arsenic was purified by using Eleocharis acicularis. The experiment was conducted to investigate the feasibility of phytoremediation by Eleocharis acicularis in civil engineering projects. In the experiment, 15 m2 of Eleocharis acicularis mats were laid in an artificial channel. Three sessions of artificial flow were implemented by leading 100.0 L of river water containing 0.234 mg/L of arsenic into the channel each time. The arsenic concentration of the leachate from the channel was analyzed. As the results of experiment, the arsenic concentrations of the leachate for the three sessions were 0.045 mg/L, 0.133 mg/L, and 0.249 mg/L. This shows that the arsenic concentration decreased during the first two sessions, whose flow totaled 200 L. The arsenic concentrations in the Eleocharis acicularis were 0.87 mg/kg, 1.01 mg/kg, and 4.16 mg/kg, which show that the plant absorbs arsenic. Moreover, it was found that the amount of sample water was reduced through evapotranspiration from the plant and the artificial channel.

  4. Highly purified water production technology. The influence of water purity on steam quality

    Ganter, J.

    1975-01-01

    The fundamental question related to high-pressure steam generation, intended for powering steam turbines, concerns steam production conditions based on constant quality standards. The characteristics of water (salinity, silica concentration) are indicated for a given steam quality as a function of the pressure. Two processes for the purification of feedwater for high pressure boilers are described: a treatment using precoated cellulose or resin filters and a treatment using mixed-bed ion exchangers. When ultrapure water is required, the demineralized water is filtred using microfiltration and ultrafiltration processes [fr

  5. Waste Water Treatment Unit

    Ramadan, A.E.K.

    2004-01-01

    A wastewater treatment plant to treat both the sanitary and industrial effluent originated from process, utilities and off site units of the refinery is described. The purpose is to obtain at the end of the treatment plant, a water quality that is in compliance with contractual requirements and relevant environmental regulations. first treatment (pretreatment). Primary de-oiling, Equalization, Neutralization, Secondary de-oiling. Second treatment (Biological), The mechanism of BOD removal, Biological flocculation, Nutrient requirements, Nitrification, De-nitrification, Effect of temperature, Effect of ph, Toxicity

  6. Investigating the characteristic strength of flocs formed from crude and purified Hibiscus extracts in water treatment.

    Jones, Alfred Ndahi; Bridgeman, John

    2016-10-15

    The growth, breakage and re-growth of flocs formed using crude and purified seed extracts of Okra (OK), Sabdariffa (SB) and Kenaf (KE) as coagulants and coagulant aids was assessed. The results showed floc size increased from 300 μm when aluminium sulphate (AS) was used as a coagulant to between 696 μm and 722 μm with the addition of 50 mg/l of OK, KE and SB crude samples as coagulant aids. Similarly, an increase in floc size was observed when each of the purified proteins was used as coagulant aid at doses of between 0.123 and 0.74 mg/l. The largest floc sizes of 741 μm, 460 μm and 571 μm were obtained with a 0.123 mg/l dose of purified Okra protein (POP), purified Sabdariffa (PSP) and purified Kenaf (PKP) respectively. Further coagulant aid addition from 0.123 to 0.74 mg/l resulted in a decrease in floc size and strength in POP and PSP. However, an increase in floc strength and reduced d50 size was observed in PKP at a dose of 0.74 mg/l. Flocs produced when using purified and crude extract samples as coagulant aids exhibited high recovery factors and strength. However, flocs exhibited greater recovery post-breakage when the extracts were used as a primary coagulant. It was observed that the combination of purified proteins and AS improved floc size, strength and recovery factors. Therefore, the applications of Hibiscus seeds in either crude or purified form increases floc growth, strength, recoverability and can also reduce the cost associated with the import of AS in developing countries. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  7. Local drinking water filters reduce diarrheal disease in Cambodia: a randomized, controlled trial of the ceramic water purifier.

    Brown, Joe; Sobsey, Mark D; Loomis, Dana

    2008-09-01

    A randomized, controlled intervention trial of two household-scale drinking water filters was conducted in a rural village in Cambodia. After collecting four weeks of baseline data on household water quality, diarrheal disease, and other data related to water use and handling practices, households were randomly assigned to one of three groups of 60 households: those receiving a ceramic water purifier (CWP), those receiving a second filter employing an iron-rich ceramic (CWP-Fe), and a control group receiving no intervention. Households were followed for 18 weeks post-baseline with biweekly follow-up. Households using either filter reported significantly less diarrheal disease during the study compared with a control group of households without filters as indicated by longitudinal prevalence ratios CWP: 0.51 (95% confidence interval [CI]: 0.41-0.63); CWP-Fe: 0.58 (95% CI: 0.47-0.71), an effect that was observed in all age groups and both sexes after controlling for clustering within households and within individuals over time.

  8. Water. Seychelles Integrated Science. [Teacher and Pupil Booklets]. Unit 3.

    Brophy, M.; Fryars, M.

    Seychelles Integrated Science (SIS), a 3-year laboratory-based science program for students (ages 11-15) in upper primary grades 7, 8, and 9, was developed from an extensive evaluation and modification of previous P7-P9 materials. This P7 SIS unit focuses on: (1) the importance of water in students' daily lives; (2) the need to purify drinking…

  9. Purifying Nanomaterials

    Hung, Ching-Cheh (Inventor); Hurst, Janet (Inventor)

    2014-01-01

    A method of purifying a nanomaterial and the resultant purified nanomaterial in which a salt, such as ferric chloride, at or near its liquid phase temperature, is used to penetrate and wet the internal surfaces of a nanomaterial to dissolve impurities that may be present, for example, from processes used in the manufacture of the nanomaterial.

  10. Study of the efficiency of some water treatment unit that present in houses in Erbil city-Iraq

    Toma, Janan. Jabbar.; Hanna, Aveen. Matti.

    2017-09-01

    Many people in Erbil city started more than two decade to put special treatment units in their houses to purified water to become safer for drinking uses. The aim of this study was determine the efficiency of six kind water treatment units which include (two replicate of Crystal Water Purifier, So-Safe Water Filter, R O Water Purifier, Kontec Water Purified and Al-Kawther Purified Water). Water samples were collected in two sites one before and other after treatment unit. Each sample was collect with three replication during May to October-2016. Analyzed for Major cations concentration (calcium, magnesium, sodium and potassium), anions concentration (nitrate and chloride) and hydrogen ion concentration (pH), electrical conductivity (EC), total dissolved solids (TDS), alkalinity and total hardness by using standard methods. The water quality index values for all raw water sample befor and after treatment was good and excellent respectively for drinking purposes. Efficiency of So-Safe Water Filter was 66.32% it means was more efficiency than others special water treatment units while in RO Water Purifier was 27.14%, means less efficiency than other water purifier water under this study. Values for major cations, anions and others chemicals characteristics in the water samples after treatment became lower concentrations than befor treatment, likely an indication that these were removed by treatment. According to guideline of world health organization all of variables except total hardness befor treatment are safe and suitable for drinking purposes.

  11. Performance Variation of Spent Resin in Mixed Bed From Water Purifying System of Xi'an Pulse Reactor

    Li Hua; Ma Yan; Xiao Yan; Liu Yueheng; Yang Yongqing

    2010-01-01

    Detailed physical and chemical characteristic analysis was performed on the spent cation and anion resins in the mixed bed from Xi'an Pulse Reactor water purifying system.The exchange performance variations of used resins and the contributions from different factors to the variation were discussed.Based on the obtained information of the impurities in the used resin, the contamination state of the water in the Xi'an Pulse Reactor water pool, the corrosion state of the structural material in the reactor was presented. The spent anion resin almost completely losses its exchange performance,while the remaining exchange capacity in the spent cation resin is still high.The radiation field from the reactor operation contributes little to the degradation of the performance of the resins. The exchange capacity loss of the spent anion resin is due to the exchange of its active groups into abundant carbonate and a certain amount of organics. The impurity amount in the anion and cation exchange resins is low,which suggests(that) the water in the Xi'an Pulse Reactor water pool is little contaminated. A certain extent of corrosion is occurred on the structural material in the swimming pool of the reactor. The results provide important referential data for the operational safety of the water purifying system of similar research reactor. (authors)

  12. Purifying hydrocarbons

    Dunstan, A E

    1918-06-03

    Ligroin, kerosene, and other distillates from petroleum and shale oil, are purified by treatment with a solution of a hypochlorite containing an excess of alkali. The hydrocarbon may be poured into brine, the mixture stirred, and an electric current passed through. Heat may be applied.

  13. Highly selective water channel activity measured by voltage clamp: analysis of planar lipid bilayers reconstituted with purified AqpZ.

    Pohl, P; Saparov, S M; Borgnia, M J; Agre, P

    2001-08-14

    Aquaporins are membrane channels selectively permeated by water or water plus glycerol. Conflicting reports have described ion conductance associated with some water channels, raising the question of whether ion conductance is a general property of the aquaporin family. To clarify this question, a defined system was developed to simultaneously measure water permeability and ion conductance. The Escherichia coli water channel aquaporin-Z (AqpZ) was studied, because it is a highly stable tetramer. Planar lipid bilayers were formed from unilamellar vesicles containing purified AqpZ. The hydraulic conductivity of bilayers made from the total extract of E. coli lipids increased 3-fold if reconstituted with AqpZ, but electric conductance was unchanged. No channel activity was detected under voltage-clamp conditions, indicating that less than one in 10(9) transport events is electrogenic. Microelectrode measurements were simultaneously undertaken adjacent to the membrane. Changes in sodium concentration profiles accompanying transmembrane water flow permitted calculation of the activation energies: 14 kcal/mol for protein-free lipid bilayers and 4 kcal/mol for lipid bilayers containing AqpZ. Neither the water permeability nor the electric conductivity exhibited voltage dependence. This sensitive system demonstrated that AqpZ is permeated by water but not charged ions and should permit direct analyses of putative electrogenic properties of other aquaporins.

  14. Performance and Health Risk Assessment of Commercial Off-the-Shelf Individual Water Purifiers

    Bettin, William; Lundquist, Arthur; Clarke, Steven; Richards, Steven

    2006-01-01

    .... This project had three discrete objectives: (1) Develop a military-use specific protocol for testing the efficiency and functionality of IWPs in producing microbiologically safe drinking water; (2...

  15. Purifying fluoride-contaminated water by a novel forward osmosis design with enhanced flux under reduced concentration polarization.

    Pal, Madhubonti; Chakrabortty, Sankha; Pal, Parimal; Linnanen, Lassi

    2015-08-01

    For purifying fluoride-contaminated water, a new forward osmosis scheme in horizontal flat-sheet cross flow module was designed and investigated. Effects of pressure, cross flow rate, draw solution and alignment of membrane module on separation and flux were studied. Concentration polarization and reverse salt diffusion got significantly reduced in the new hydrodynamic regime. This resulted in less membrane fouling, better solute separation and higher pure water flux than in a conventional module. The entire scheme was completed in two stages-an upstream forward osmosis for separating pure water from contaminated water and a downstream nanofiltration operation for continuous recovery and recycle of draw solute. Synchronization of these two stages of operation resulted in a continuous, steady-state process. From a set of commercial membranes, two polyamide composite membranes were screened out for the upstream and downstream filtrations. A 0.3-M NaCl solution was found to be the best one for forward osmosis draw solution. Potable water with less than 1% residual fluoride could be produced at a high flux of 60-62 L m(-2) h(-1) whereas more than 99% draw solute could be recovered and recycled in the downstream nanofiltration stage from where flux was 62-65 L m(-2) h(-1).

  16. Thin layer settling - a promising method for purifying industrial waste waters

    Perevalov, V G; Kolokhmatova, N M; Malkina, I I; Smyslov, A I

    1979-01-01

    Proposed for removing oil and suspended substances from waste waters is a thin layer, tubular settler, whose elements are made from polyethylene pipes. The operational effectiveness of the settler on the average is 90-95%, the duration of the purification is 10-11 min, which is 1/12 of that in the most common and contemporary oil traps. The volume of the settler structure with this productivity may be reduced by 12 times.

  17. Purifying hydrocarbons

    Demoulins, H D; Garner, F H

    1923-02-07

    Hydrocarbon distillates, including natural gases and vapors produced by cracking hydrocarbon oils, are desulfurized etc. by treating the vapor with an aqueous alkaline solution of an oxidizing agent. The hydrocarbons may be previously purified by sulfuric acid. In examples aqueous solutions of sodium or calcium hydrochlorite containing 1.5 to 5.0 grams per liter of available chlorine and sufficient alkali to give an excess of 0.1 percent in the spent reagent are preheated to the temperature of the vapor, and either sprayed or atomized into the vapors near the outlet of the dephlegmator or fractionating tower, or passed in countercurrent to the vapors through one or a series of scrubbers.

  18. Purifying oils

    1930-04-15

    Gasoline, lamp oils, and lubricating or other mineral or shale oils are refined by contacting the vapor with a hot aqueous solution of salts of zinc, cadmium, or mercury, or mixtures thereof which may contain 0-5-3-0 percent of oxide or hydroxide in solution or suspension. Chlorides, bromides, iodides, sulfates, nitrates, and sulfonates of benzol, toluol, xylol, and petroleum are specified. Washing with a solution of sodium or potassium hydroxide or carbonate of calcium hydroxide may follow. The oil may first be purified by sulfuric acid or other known agent, or afterwards caustic alkali and sulfuric acid. The Specification as open to inspection under Sect. 91 (3) (a) describes also the use of salts of copper, iron, chromium, manganese, aluminum, nickel, or cobalt, with or without their oxides or hydroxides. This subject-matter does not appear in the Specification as accepted.

  19. Purifying hydrocarbons

    Forwood, G F; Lane, M; Taplay, J G

    1917-10-27

    Shale spirit, crude benzol, and other oils are treated for the removal of sulfur by washing with a solution of the sulfides of the alkalis or alkaline earths. The reagent may be prepared by saturating a strong solution of caustic potash with sulfuretted hydrogen and with flowers of sulfur in succession. The treatment may be effected by agitating the oil with the reagent for about six hours, or by heating them to about 40/sup 0/C. The reagent is drawn off, and the oil is washed with water, then with dilute caustic soda solution, and finally with water.

  20. A Novel Ion Exchange System to Purify Mixed ISS Waste Water Brines for Chemical Production and Enhanced Water Recovery

    Lunn, Griffin; Spencer, LaShelle; Ruby, Anna-Maria; McCaskill, Andrew

    2014-01-01

    Current International Space Station water recovery regimes produce a sizable portion of waste water brine. This brine is highly toxic and water recovery is poor: a highly wasteful proposition. With new biological techniques that do not require waste water chemical pretreatment, the resulting brine would be chromium-free and nitrate rich which can allow possible fertilizer recovery for future plant systems. Using a system of ion exchange resins we can remove hardness, sulfate, phosphate and nitrate from these brines to leave only sodium and potassium chloride. At this point modern chlor-alkali cells can be utilized to produce a low salt stream as well as an acid and base stream. The first stream can be used to gain higher water recovery through recycle to the water separation stage while the last two streams can be used to regenerate the ion exchange beds used here, as well as other ion exchange beds in the ISS. Conveniently these waste products from ion exchange regeneration would be suitable as plant fertilizer. In this report we go over the performance of state of the art resins designed for high selectivity of target ions under brine conditions. Using ersatz ISS waste water we can evaluate the performance of specific resins and calculate mass balances to determine resin effectiveness and process viability. If this system is feasible then we will be one step closer to closed loop environmental control and life support systems (ECLSS) for current or future applications.

  1. Energy efficient and adiabatic humidification. Reversed osmosis principle purifies water; Energiezuinig en adiabatisch bevochtigen. Omgekeerd-osmose principe zuivert water

    Brands, R. [Cumulus Nederland, Cuijk (Netherlands)

    2006-11-15

    For decades air conditioners are equipped with humidifiers. A large number of humidifier types are available. Adiabatic humidification is an energy efficient technique, although it is important to control the installation conditions, water treatment (reversed osmosis) and the risk of legionella. [Dutch] Al decennia lang worden er luchtbehandelingkasten gebouwd met een bevochtigingssectie. Door de jaren heen is een enorme verscheidenheid ontstaan van bevochtigingssystemen. Adiabatische bevochtiging staat in de belangstelling vanwege het lagere energiegebruik. Hierbij moeten de installatievoorwaarden, de waterbehandeling (omgekeerde osmose) en het legionellarisico goed in de gaten worden gehouden.

  2. Process for purifying graphite

    Clausius, R.A.

    1985-01-01

    A process for purifying graphite comprising: comminuting graphite containing mineral matter to liberate at least a portion of the graphite particles from the mineral matter; mixing the comminuted graphite particles containing mineral matter with water and hydrocarbon oil to form a fluid slurry; separating a water phase containing mineral matter and a hydrocarbon oil phase containing grahite particles; and separating the graphite particles from the hydrocarbon oil to obtain graphite particles reduced in mineral matter. Depending upon the purity of the graphite desired, steps of the process can be repeated one or more times to provide a progressively purer graphite

  3. Extent and effects of recurrent shortages of purified-protein derivative tuberculin skin test antigen solutions - United States, 2013.

    2013-12-13

    Two purified-protein derivative (PPD) tuberculin skin test (TST) antigen solutions are approved by the U.S. Food and Drug Administration (FDA): Tubersol (Sanofi Pasteur Limited) and Aplisol (JHP Pharmaceuticals, LLC). Tubersol was out of production in late 2012 through April 2013. Shortages of Aplisol have resulted from increased demand as practitioners have sought a substitute for Tubersol. Tubersol production resumed in May 2013, and supplies had been nearly restored by early June. However, in mid-July, state tuberculosis (TB) control officials notified CDC of difficulty obtaining Tubersol and Aplisol. Sanofi Pasteur notified FDA of a temporary delay in the availability of tuberculin in the 10-dose and 50-dose presentations. In mid-October, the 10-dose presentation was being returned to market, on allocation, which means that historical purchasing practices determine the amount that customers are allotted. In late October, the 50-dose presentation was being returned to market, also on allocation, one vial per historical customer per month. Supplies are forecast to approach normal during January 2014, after distributors have restored their supply chains. A compensatory surge in testing after deferment of testing during the periods of shortage might cause further temporary instability of supplies. In mid-August 2013, officials in 29 of 52 U.S. jurisdictions noted a shortage of at least one PPD TST antigen solution in health departments to the extent that it interrupted activities. This report includes a summary of the extent and effects of the shortages and a reiteration of advice on how to adapt to them.

  4. Strategic of Applying Free Chemical Usage In Purified Water System For Pharmaceutical Industry Toward CPOB (Cara Pembuatan Obat yang Baik Indonesia To Reducing Environmental Pollution

    Kartono R.

    2014-03-01

    Full Text Available The purpose of this paper is to examine the sets of model and literature review to prove that strategy of applying free chemical usage in purified water system for pharmaceutical industry would be help the existing and new pharmaceutical companies to comply with part of Natioanal Agency of Drug and Food Control / Badan Pengawas Obat dan Makanan (NADFC/BPOM regulation in order to achieve “Cara Pembuatan Obat yang Baik” (CPOB of Indonesia pharmaceutical industry. One of the main reasons is when we figured out the number of Indonesian pharmaceutical industries in 2012 are kept reducing compare to the increasing numbers of Indonesian population growth. This strategy concept also might help the industries to reducing environmental pollution, and operational cost in pharmaceutical industries, by reducing of the chemical usage for water treatment process in floculation and cougulation and chlorination for sterillization. This new model is free usage of chemicals for purified water generation system process and sterilization. The concept offering of using membrane technology- Reverse Osmosis (RO membrane base treatment to replace traditional chemical base treatment, following enhance Electrodeionization (EDI as final polisher for controlling conductivity, and finally Ultra Violet (UV disinfectant technology as final guard for bacteria controls instead of chemical base system in purified water generation system.

  5. Strategic of Applying Free Chemical Usage In Purified Water System For Pharmaceutical Industry Toward CPOB (Cara Pembuatan Obat yang Baik) Indonesia To Reducing Environmental Pollution

    Kartono, R.; Basuki, Y. T.

    2014-03-01

    The purpose of this paper is to examine the sets of model and literature review to prove that strategy of applying free chemical usage in purified water system for pharmaceutical industry would be help the existing and new pharmaceutical companies to comply with part of Natioanal Agency of Drug and Food Control / Badan Pengawas Obat dan Makanan (NADFC/BPOM) regulation in order to achieve "Cara Pembuatan Obat yang Baik" (CPOB) of Indonesia pharmaceutical industry. One of the main reasons is when we figured out the number of Indonesian pharmaceutical industries in 2012 are kept reducing compare to the increasing numbers of Indonesian population growth. This strategy concept also might help the industries to reducing environmental pollution, and operational cost in pharmaceutical industries, by reducing of the chemical usage for water treatment process in floculation and cougulation and chlorination for sterillization. This new model is free usage of chemicals for purified water generation system process and sterilization. The concept offering of using membrane technology- Reverse Osmosis (RO) membrane base treatment to replace traditional chemical base treatment, following enhance Electrodeionization (EDI) as final polisher for controlling conductivity, and finally Ultra Violet (UV) disinfectant technology as final guard for bacteria controls instead of chemical base system in purified water generation system.

  6. Simplified calculation of investment costs involved in purifying industrial waste water. Calculo simplificado de los costes de inversion en la depuracion de aguas residuales industriales

    Queralt, R. (Junta de Saneamientos. Generalidad de Catalua (Spain))

    1993-03-01

    The calculation of the investment involved in purifying industrial waste water poses certain problems since this is affected either by employing complicated methods which require a great deal of data or, as the sole alternative, through subjective estimates. The present article purposes an intermediate system based on simplified formulas for which it is only necessary to know three parameters, namely, (in the majority of cases) the industrial activity, the flow and the Q.O.D. (Author)

  7. Solar power water distillation unit

    Hameed, Kamran; Khan, Muhammad Muzammil; Ateeq, Ijlal Shahrukh; Omair, Syed Muhammad; Ahmer, Muhammad; Wajid, Abdul

    2013-01-01

    Clean drinking water is the basic necessity for every human being, but about 1.1 billion people in the world lacked proper drinking water. There are many different types of water purification processes such as filtration, reverse osmosis, ultraviolet radiation, carbon absorption, but the most reliable processes are distillation and boiling. Water purification, such as distillation, is especially important in regions where water resources or tap water is not suitable for ingesting without boiling or chemical treatment. In design project It treats the water by combining different methods such as Filtration, Distillation and a technique called concentrated solar power (CSP). Distillation is literally the method seen in nature, whereby: the sun heats the water on the earth's surface, the water is turned into a vapor (evaporation) and rises, leaving contaminants behind, to form clouds. As the upper atmosphere drops in temperature the vapors cool and convert back to water to form water. In this project distillation is achieved by using a parabolic mirror which boils water at high temperature. Filtration is done by sand filter and carbon filter. First sand filter catches the sand particles and the carbon filter which has granules of active carbon is used to remove odor dissolved gases from water. This is the Pre-treatment of water. The filtered water is then collected in a water container at a focus of parabolic mirror where distillation process is done. Another important feature of designed project is the solar tracking of a parabolic mirror which increases the efficiency of a parabolic mirror [1],[2].

  8. Purification by ozonolysis of 18O enriched water after cyclotron irradiation and the utilization of the purified water for the production of [18F]-FDG (2-deoxy-2-[18F]-fluoro-D-glucose)

    Asti, M.; Grassi, E.; Sghedoni, R.; De Pietri, G.; Fioroni, F.; Versari, A.; Borasi, G.; Salvo, D.

    2007-01-01

    The high cost of virgin 18 O-enriched water has forced many researchers to study methods to purify and recycle enriched water after the first irradiation for the production of radiopharmaceuticals. In our study, [ 18 O]H 2 O was purified by ozonolysis and distillation. Analyses showed a large decrease in impurities after this treatment. The purification procedure was carried out after the production of 94 batches of [ 18 F]-FDG, which were manufactured using a GE Minitrace cyclotron and a GE Mx TracerLab synthesizer. Saturation yields after bombardment, using virgin and re-purified water were, respectively, 2864±204 MBq/μA and 2727±167 MBq/μA, a decrease of 5.5%. The decrease in [ 18 F]-FDG yield, from 67.2±0.7% to 65.5±0.9%, can be ascribed to the irradiation step only

  9. Portable field water sample filtration unit

    Hebert, A.J.; Young, G.G.

    1977-01-01

    A lightweight back-packable field-tested filtration unit is described. The unit is easily cleaned without cross contamination at the part-per-billion level and allows rapid filtration of boiling hot and sometimes muddy water. The filtration results in samples that are free of bacteria and particulates and which resist algae growth even after storage for months. 3 figures

  10. Factors affecting continued use of ceramic water purifiers distributed to Tsunami-affected Communities in Sri Lanka

    Casanova, Lisa M; Walters, Adam; Naghawatte, Ajith; Sobsey, Mark D

    2012-01-01

    Objectives  There is little information about continued use of point-of-use technologies after disaster relief efforts. After the 2004 tsunami, the Red Cross distributed ceramic water filters in Sri Lanka. This study determined factors associated with filter disuse and evaluate the quality of household drinking water. Methods  A cross-sectional survey of water sources and treatment, filter use and household characteristics was administered by in-person oral interview, and household water qual...

  11. Factors affecting continued use of ceramic water purifiers distributed to tsunami-affected communities in Sri Lanka.

    Casanova, Lisa M; Walters, Adam; Naghawatte, Ajith; Sobsey, Mark D

    2012-11-01

    There is little information about continued use of point-of-use technologies after disaster relief efforts. After the 2004 tsunami, the Red Cross distributed ceramic water filters in Sri Lanka. This study determined factors associated with filter disuse and evaluate the quality of household drinking water. A cross-sectional survey of water sources and treatment, filter use and household characteristics was administered by in-person oral interview, and household water quality was tested. Multivariable logistic regression was used to model probability of filter non-use. At the time of survey, 24% of households (107/452) did not use filters; the most common reason given was breakage (42%). The most common household water sources were taps and wells. Wells were used by 45% of filter users and 28% of non-users. Of households with taps, 75% had source water Escherichia coli in the lowest World Health Organisation risk category (<1/100 ml), vs. only 30% of households reporting wells did. Tap households were approximately four times more likely to discontinue filter use than well households. After 2 years, 24% of households were non-users. The main factors were breakage and household water source; households with taps were more likely to stop use than households with wells. Tap water users also had higher-quality source water, suggesting that disuse is not necessarily negative and monitoring of water quality can aid decision-making about continued use. To promote continued use, disaster recovery filter distribution efforts must be joined with capacity building for long-term water monitoring, supply chains and local production. © 2012 Blackwell Publishing Ltd.

  12. Effectiveness of inorganic membrane mixture of natural zeolite and portland white cement in purifying of peat water based on turbidity parameter

    Elfiana; Fuadi, A.; Diana, S.

    2018-04-01

    Peat water is water surface that brownish red colour caused by the contained constituents. Solving the peat watercolor problem requires special attention considering the quantity of peat water and suitable to be used to meet the daily needs. This study aims to know the inorganic membrane capability of mix nature zeolite and white Portland cement to purifying the peat water based on turbidity parameter. The study was conducted by varying the composition of nature zeolite (Za) and white Portland cement (Sp) in the ratio of Za: Sp is (25%:75%; 50%:50%; 75%:25%) with zeolite condition activated using HCl 2M and nonactivated zeolite treatments. The result of the characteristic test on membrane morphology using SEM (Scanning Electron Microscope) showed that the pore surface size of the membrane is 2 μm that could classified in microfiltration membrane an organic type. The characteristic test showed also resulted in the density of 0.77 to 0.86 gr/cm3, porosity 26.22% to 35.93%, and permeability 2736.19 to 8428.15. While the water retention capacity is in range of 30.64% to 46.46%, The result of inorganic membrane application on peat water showed turbidity of peat water decreased 94.17%, from 10.3 NTU to 0.6 NTU.

  13. Purifying waste waters in the surface treatment industry; Depuracion de las aguas residuales en la industria de tratamiento de superficies

    Queralt Torrell, R.; Martinez Hidalgo, E. [Generalitat de Catalunya. Barcelona (Spain)

    1999-07-01

    The electrolytic coating industry in Spain comprises some 2,000 firms whose waste waters are highly problematic, mainly due to the presence of heavy metals and cyanides. This article sets out series of internal measures for conserving the baths, reducing entrainment and optimising washes, thereby minimising the volume and concentration of the waste waters. It also discusses the advantages and disadvantages of the different chemical reagents employed in the physicochemical treatment of waste waters during the oxidation/reduction and metal precipitation processes. In addition, it mentions other techniques such as the use of ion exchange resins, membranes and electro-coagulation, which are becoming increasingly widespread. Finally, it offers a summary report on 11 waste water treatment facilities installed in different surface treatment factories. (Author) 21 refs.

  14. Effect of ultrasonic pretreatment on purified water disinfection; Efecto del pretratamiento con ultrasonidos sobre la desinfeccion de agua depurada

    Simon Andreu, P.; Lardin Mifsut, C.; Vergara Romero, L.; Polo Canas, P. M.; Perez Sanchez, P.; Rancano Perez, A.

    2009-07-01

    Due to the importance of a suitable water disinfection in order to insure a pollutant effect minimization against environment, this work has been carried out to determine how can affect an ultrasonic pre-treatment upon disinfection step. It has been confirmed the ultrasonic disintegration of bacterial cells in treated water and disinfectant power of treatment by itself, which is not enough to be used as a single method in water disinfection. It has also been proved that from a technical and economical point of view the combination of UV and ultrasound improves the UV treatment performance. Finally, it has been detected that an ultrasonic pre-treatment increases chlorination effectiveness, however the high cost in this combination makes it unfeasible of industrial scale. (Author) 6 refs.

  15. Intra- and inter-individual variations of blood and urinary water-soluble vitamins in Japanese young adults consuming a semi-purified diet for 7 days.

    Shibata, Katsumi; Fukuwatari, Tsutomu; Watanabe, Toshiaki; Nishimuta, Mamoru

    2009-12-01

    We have previously reported the levels of water-soluble vitamins in the blood and urine of Japanese young adults. In the present paper, to assess the variations in these water-soluble vitamin markers during the above experiment, we comprehensively determined the intra- and inter-individual variations of blood and urinary water-soluble vitamins to exactly the same amount of water-soluble vitamin intakes in the same experiment. The blood samples before breakfast and the 24-h urine samples were periodically collected from Japanese college male (n=10) and female (n=10) students consuming a semi-purified diet with water-soluble vitamins based on Japanese Dietary Reference Intakes for 7 d, and the intra- and inter-individual variations of blood and urinary water-soluble vitamins or their metabolites in blood and urine samples after adaptation were calculated. Although urinary excretion of vitamin B(12) and vitamin C showed high intra-individual variations in both males and females, other urinary vitamins and all blood vitamins showed less than 20% of within-subject coefficients of variance in either male or female. Those showing more than 20% of between-subject coefficients of variances in both male and female were blood vitamin B(6), vitamin B(12) and folate levels, and urinary vitamin B(1), vitamin B(2), vitamin B(12), nicotinamide metabolites, pantothenic acid, biotin and vitamin C. These results showed that oral administration of constant of water-soluble vitamins generally decreased intra-individual variation, while individual differences in urinary vitamin excretion were observed.

  16. The pollution of the sea water by the waste from the LNG plant Arzew-Algeria and the waste water purifying system

    Meniuar, H.

    2003-01-01

    Full text: Generally, the pollution makes a lot of problems for the environment. The natural gas (N.G.) is a compound of the light hydrocarbons, methane, ethane, propane, butane and other trace elements, like Helium, Nitrogen, Carbon Dioxide and others. After the different zones of the natural gas treatment, a problem of pollution of water is appeared. In this plant there are eight zones, six units of process, one for the energy production and another for the storage. It exists a system to treat all the effluents contamination coming from these zones. The treatment of this waste water consists in the separation of the oil and the sludge to satisfy the standard environmental protection. There are six separators, pools of concrete are connected with a collector for supply which is connected with each separator by three conduits. A diffusion apparatus is put in front of every nozzle of entry in the separator, and this is for a suitable distribution of the liquid in the separator. In reason of the decrease speed of the liquid when it passes through the separator, the particles carried, deposit in the bottom of the separator. The suspended matters are collected by a chain collector. The float matters up the liquid of the separators, mainly oils, are removed through the creaming tubs

  17. Use of Ferrihydrite-Coated Pozzolana and Biogenic Green Rust to Purify Waste Water Containing Phosphate and Nitrate

    Ruby, Christian; Naille, Sébastien; Ona-Nguema, Georges; Morin, Guillaume; Mallet, Martine; Guerbois, Delphine; Barthélémy, Kévin; Etique, Marjorie; Zegeye, Asfaw; Zhang, Yuhai; Boumaïza, Hella; Al-Jaberi, Muayad; Renard, Aurélien; Noël, Vincent; Binda, Paul; Hanna, Khalil; Despas, Christelle; Abdelmoula, Mustapha; Kukkadapu, Ravi; Sarrias, Joseph; Albignac, Magali; Rocklin, Pascal; Nauleau, Fabrice; Hyvrard, Nathalie; Génin, Jean-Marie

    2016-06-27

    The activated sludge treatments combined to the addition of ferric chloride is commonly used to eliminate nitrate and phosphate from waste water in urban area. These processes that need costly infrastructures are not suitable for rural areas and passive treatments (lagoons, reed bed filters…) are more frequently performed. Reed bed filters are efficient for removing organic matter but are not suitable for treating phosphate and nitrate as well. Passive water treatments using various materials (hydroxyapatite, slag…) were already performed, but those allowing the elimination of both nitrate and phosphate are not actually available. The goal of this work is to identify the most suitable iron based materials for such treatments and to determine their optimal use conditions, in particular in hydrodynamic mode. The reactivity of the iron based minerals was measured either by using free particles in suspension or by depositing these particles on a solid substrate. Pouzzolana that is characterized by a porous sponge-like structure suits for settling a high amount of iron oxides. The experimental conditions enabling to avoid any ammonium formation when green rust encounters nitrate were determined within the framework of a full factorial design. The process is divided into two steps that will be performed inside two separated reactors. Indeed, the presence of phosphate inhibits the reduction of nitrate by green rust and the dephosphatation process must precede the denitrification process. In order to remove phosphate, ferrihydrite coated pouzzolana is the best materials. The kinetics of reaction of green rust with nitrate is relatively slow and often leads to the formation of ammonium. The recommendation of the identified process is to favor the accumulation of nitrite in a first step, these species reacting much more quickly with green rust and do not transform into ammonium.

  18. Method for removing cesium from aqueous liquid, method for purifying the reactor coolant in boiling water and pressurized water reactors and a mixed ion exchanged resin bed, useful in said purification

    Otte, J.N.A.; Liebmann, D.

    1989-01-01

    The invention relates to a method for removing cesium from an aqueous liquid, and to a resin bed containing a mixture of an anion exchange resin and cation exchange resin useful in said purification. In a preferred embodiment, the present invention is a method for purifying the reactor coolant of a presurized water or boiling water reactor. Said method, which is particularly advantageously employed in purifying the reactor coolant in the primary circuit of a pressurized reactor, comprises contacting at least a portion of the reactor coolant with a strong base anion exchange resin and the strong acid cation exchange resin derived from a highly cross-linked, macroporous copolymer of a monovinylidene aromatic and a cross-linking monomer copolymerizable therewith. Although the reactor coolant can sequentially be contacted with one resin type and thereafter with the second resin type, the contact is preferably conducted using a resin bed comprising a mixture of the cation and anion exchange resins. 1 fig., refs

  19. 33 CFR 2.36 - Navigable waters of the United States, navigable waters, and territorial waters.

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Navigable waters of the United States, navigable waters, and territorial waters. 2.36 Section 2.36 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY GENERAL JURISDICTION Jurisdictional Terms § 2.36 Navigable waters...

  20. Handbook of purified gases

    Schoen, Helmut

    2015-01-01

    Technical gases are used in almost every field of industry, science and medicine and also as a means of control by government authorities and institutions and are regarded as indispensable means of assistance. In this complete handbook of purified gases the physical foundations of purified gases and mixtures as well as their manufacturing, purification, analysis, storage, handling and transport are presented in a comprehensive way. This important reference work is accompanied with a large number of Data Sheets dedicated to the most important purified gases.  

  1. Treatment of mine water. A German joint project purifies highly charged mine water in Vietnam; Behandlung von Bergbauabwasser. Ein deutsches Verbundprojekt reinigt in Vietnam stark belastete Bergbauabwaesser

    Kurtz, Stefan; Bilek, Felix [GFI Grundwasserforschungsinstitut GmbH, Dresden (Germany); Kochan, Hans-Juergen [eta AG/LUG Enginering GmbH, Cottbus (Germany); Denke, Peter [LMBV international GmbH, Senftenberg (Germany)

    2011-09-15

    As part of the joint project RAME 'Mining and Environment in Vietnam', a pilot plant for the purification of mine water arises in Vietnam. In cooperation with Vietnamese partners, for the first time an active method for the purification of mine water is used in Vang Danh. The research tasks and development activities necessary for the process development are funded in part by the Federal Ministry of Education and Research (Berlin, Federal Republic of Germany). The construction of the mine water treatment plant is described in addition to the specific national conditions.

  2. Purifying hydrocarbon oils

    Rostin, H

    1938-08-11

    A process is described for continuously purifying hydrocarbon oils consisting in conducting the vapors of the same at a temperature of 300 to 400/sup 0/C over the oelitic ore minette together with reducing gases in presence of steam the proportion of the reducing gases and steam being such that the sulfur of the hydrocarbons escapes from the reaction chamber in the form of sulfuretted hydrogen without permanent sulfide of iron being formed.

  3. Salts, sodium and heavy metals, in residual waters not purified, used for the watering in the cultivation of the sugar cane

    Mendez Romero, Franky Jose; Gisbert-Banquert, Juan Manuel

    2003-01-01

    In a farm located in the Valencia Lake Basin at northeast of Guacara city (Venezuelan country) and cultivated with sugar cane crop was evaluated during the period of July of 1996 to June of 1997 the salinity, sodicity and heavy metals concentration In municipal wastewater using to gravity Irrigated the sugar cane crop. The salinity was determinate by EC direct measure In Irrigation water (standardized at 25 Celsius degrade, Sodium by flame photometer Calcium and Magnesium by titulation with EDTA Cd, Cu, Fe Mn, Ni and Zn, were determinate by AAS before water samples preserve with NO 3 H. The wastewater quality employ to Irrigated the sugar cane crop was evaluated by mean of the Venezuelan official water Laws (1995) and compare too with the directives mentioned by Pratt and Suarez (1990), Crook and Bastian (1992) and the Mexican official wastewater irrigation laws NOM-CAA-032-ECOL/93 (1993. The results showed than the wastewater using to Irrigated the sugar cane field crop could to bring light and strong problems by salinity and sodium so much the soil as the crop The concentration of Cd, Fe and Cu are outside Limits proposals the Venezuelan official water laws (1995) Also when comparing the results with the other directives all the heavy metal concentration are outside the proposed Limits In each one of them except the Zn. In any case, the continuous use of the wastewater treated in this research could generate potential contamination and toxicity problems by heavy metals, salts and sodium In the crop, soils, groundwater and the people

  4. Water absorption characteristic of interlocking compressed earth brick units

    Bakar, B. H. Abu; Saari, S.; Surip, N. A.

    2017-10-01

    This study aims to investigate the water absorption characteristic of interlocking compressed earth brick (ICEB) units. Apart from compressive strength, water absorption is an important property in masonry. This property can affect the quality of the brick itself and the bond strength between the brick and mortar in masonry structures and can result in reducing its strength properties. The units were tested for 24 h water absorption and 5 h boiling water absorption. A total of 170 ICEB units from four ICEB types underwent both tests. For the 24 h water absorption, the ICEB units were dried in the oven for 24 h and then cooled before being weighed. Thereafter, each brick was immersed in water for 24 h and weighed. The same specimens used for the 24 h water absorption test were re-used for the 5 h boiling water absorption test. After completing the 24 h water absorption test, the brick was boiled for 5-hours and weighed. The highest water absorption for the ICEBs in the 24-hour water absorption and 5 h boiling water absorption tests are 15.09% and 17.18%, respectively. The half brick has the highest water absorption (15.87%), whereas the beam brick has the lowest (13.20%). The water absorption of an ICEB unit is higher than that of normal bricks, although the water absorption of the former remains below the maximum rate of the brick water absorption (21%).

  5. Process for purifying molybdenum

    Cheresnowsky, J.

    1989-01-01

    This patent describes a process for purifying molybdenum containing arsenic and phosphorus. The process comprising: adding to an acidic slurry of molybdenum trioxide, a source of magnesium ions in a solid form, with the amount of magnesium and the magnesium ion concentration in the subsequently formed ammonium molybdate solution being sufficient to subsequently form insoluble compounds containing greater than about 80% by weight of the arsenic and greater than about 80% by weight of the phosphorus, and ammonia in an amount sufficient to subsequently dissolve the molybdenum and subsequently form the insoluble compounds, with the source of magnesium ions being added prior to the addition of the ammonia; digesting the resulting ammoniated slurry at a temperature sufficient to dissolve the molybdenum and form an ammonium molybdate solution while the pH is maintained at from bout 9 to about 10 to form a solid containing the insoluble compounds; and separating the solid from the ammonium molybdate solution

  6. Home Air Purifiers Eradicate Harmful Pathogens

    2014-01-01

    Marshall Space Flight Center funded the University of Madison-Wisconsin to develop ethylene scrubbers to keep produce fresh in space. Akida Holdings of Jacksonville, Florida, licensed the technology and developed Airocide, an air purifier that can kill airborne pathogens. Previously designed for industrial spaces, there is now a specially designed unit for home use.

  7. Development of Water Quality Modeling in the United States

    This presentation describes historical trends in water quality model development in the United States, reviews current efforts, and projects promising future directions. Water quality modeling has a relatively long history in the United States. While its origins lie in the work...

  8. Future United States Domestic Water Demand

    U.S. Environmental Protection Agency — Population projections, estimated per capita consumption rate, and estimated total annual water demand to 2100 for four future projections based off the IPCC SRES...

  9. Decontamination efficiencies of pot-type water purifiers for ¹³¹I, ¹³⁴Cs and ¹³⁷Cs in rainwater contaminated during Fukushima Daiichi nuclear disaster.

    Shogo Higaki

    Full Text Available Rainwater was contaminated by a large release of radionuclides into the environment during the Fukushima Daiichi nuclear disaster. It became a matter of concern for Japan when several water purification plants detected ¹³¹I contamination in the drinking water. In the present study, the decontamination efficiency of two easily obtainable commercial water purifiers were examined for rainwater contaminated with ¹³¹I, ¹³⁴Cs and ¹³⁷Cs. The water purifiers removed 94.2-97.8% of the ¹³¹I and 84.2-91.5% of the ¹³⁴Cs and ¹³⁷Cs after one filtration. Seven filtrations removed 98.2-99.6% of the ¹³¹I and over 98.0% of the ¹³⁴Cs and ¹³⁷Cs. From a practical perspective, over the fourth filtrations were not needed because of no significant improvements after the third filtration.

  10. Forest management and water in the United States [Chapter 13

    Daniel G. Neary

    2017-01-01

    This chapter outlines a brief history of the United States native forests and forest plantations. It describes the past and current natural and plantation forest distribution (map, area, main species), as well as main products produced (timber, pulp, furniture, etc.). Integrated into this discussion is a characterization of the water resources of the United States and...

  11. An environmental assessment of United States drinking water watersheds

    James Wickham; Timothy Wade; Kurt Riitters

    2011-01-01

    Abstract There is an emerging recognition that natural lands and their conservation are important elements of a sustainable drinking water infrastructure. We conducted a national, watershed-level environmental assessment of 5,265 drinking water watersheds using data on land cover, hydrography and conservation status. Approximately 78% of the conterminous United States...

  12. Monitoring water for radioactive releases in the United States

    Porter, C.R.; Broadway, J.A.; Kahn, B.

    1990-01-01

    The major radiological environmental monitoring programs for water in the United States are described. The applications of these programs for monitoring radioactive fallout, routine discharges from nuclear facilities, and releases due to accidents at such facilities are discussed, and some examples of measurements are presented. The programs monitor rainfall, surface water, and water supplies. Samples are usually collected and analyzed on a monthly or quarterly schedule, but the frequency is increased in response to emergencies. (author)

  13. Purifying arsenic and fluoride-contaminated water by a novel graphene-based nanocomposite membrane of enhanced selectivity and sustained flux.

    Pal, Madhubonti; Mondal, Mrinal Kanti; Paine, Tapan Kanti; Pal, Parimal

    2018-06-01

    A novel graphene-based nanocomposite membrane was synthesized by interfacial polymerization (IP) through chemical bonding of the graphene oxide (GO) layer to polyethersulfone surface. Detailed characterization of the composite membrane through AFM, SEM, ATR-FTIR, XRD analysis, and Raman spectroscopy indicates strong potential of the membrane in highly selective removal of the toxic contaminants like arsenic and fluoride while permeating the essential minerals like calcium and magnesium. This makes the membrane suitable for production of safe drinking water from contaminated water. The membrane applied in a flat-sheet cross-flow module succeeded in removal of more than 98% arsenic and around 80% fluoride from contaminated water while selectively retaining the useful calcium and magnesium minerals in drinking water. A sustained pure water flux of around 150 LMH (liter per square meter per hour) during operation over long hours (> 150 h) with only 3-5% drop in flux indicates antifouling character of the membrane module.

  14. Water Use in the United States Energy System: A National Assessment and Unit Process Inventory of Water Consumption and Withdrawals.

    Grubert, Emily; Sanders, Kelly T

    2018-06-05

    The United States (US) energy system is a large water user, but the nature of that use is poorly understood. To support resource comanagement and fill this noted gap in the literature, this work presents detailed estimates for US-based water consumption and withdrawals for the US energy system as of 2014, including both intensity values and the first known estimate of total water consumption and withdrawal by the US energy system. We address 126 unit processes, many of which are new additions to the literature, differentiated among 17 fuel cycles, five life cycle stages, three water source categories, and four levels of water quality. Overall coverage is about 99% of commercially traded US primary energy consumption with detailed energy flows by unit process. Energy-related water consumption, or water removed from its source and not directly returned, accounts for about 10% of both total and freshwater US water consumption. Major consumers include biofuels (via irrigation), oil (via deep well injection, usually of nonfreshwater), and hydropower (via evaporation and seepage). The US energy system also accounts for about 40% of both total and freshwater US water withdrawals, i.e., water removed from its source regardless of fate. About 70% of withdrawals are associated with the once-through cooling systems of approximately 300 steam cycle power plants that produce about 25% of US electricity.

  15. Experience of Ko-Ri Unit 1 water chemistry

    Tae Il Lee

    1983-01-01

    The main focus is placed on operational experience in secondary system water chemistry (especially the steam generator) of the Ko-Ri nuclear power plant Unit 1, Republic of Korea, but primary side chemistry is also discussed. The major concern of secondary water chemistry in a PWR is that the condition of the steam generator be well maintained. Full flow deep bed condensate polishers have recently been installed and operation started in July 1982. Boric acid treatment of the steam generator was stopped and only the all volatile treatment method was used thereafter. A review of steam generator integrity, the chemistry control programme, secondary water quality, etc. is considered to be of great value regarding the operation of Unit 1 and future units now under startup testing or construction in the Republic of Korea. (author)

  16. A Well Water Reverse Osmosis Desalination Unit Diagnosis

    Elfil, H.; Hila, M.; Hannachi, A.; Yeza, A.

    2009-01-01

    In this present work the diagnosis results of a reverse osmosis desalination unit are reported. Since 1997, the desalination unit was supplying a 1200 bed hotel. The feed water was driven from a well situated 300 m away form the sea. The water has an approximate salinity of 6gg.L -1 . The unit was producing 600 m 3 per day of desalinated water with a Total Dissolved Salts (TDS) of nearly 400 mg.L -1 . The desalination unit has two stages with 67 pour cent and 42 pour cent yields respectively giving an average yield of 81 pour cent. The behavior of all water streams with respect to aggressiveness and scaling tendency was assessed. The 2nd stage reject water was shown to exhibit a very high scaling behavior with an instantaneous precipitation in the absence of feed water chemical treatment. The analyses have shown that the produced water was very aggressive. The second stage module autopsy has revealed a sharp decrease of the membrane performances because of mineral as well as organic fooling buildup. The inorganic scale was essentially made of coesite and calcite and kaolinite clay. The presence of silica and clay could be attributed to an inadequate filtration pre-treatment process that was not able to retain all the suspended matter in the feed water. Whereas the presence calcite crystals at the membrane surface, reveals that the chemical inhibition performed at the pre-treatment process without adjusting the water pH was not able to prevent calcium carbonate precipitation. A periodic acid wash of the 2nd stage membranes is then necessary to guarantee this stage desired objectives.

  17. Water Savings of Crop Redistribution in the United States

    Kyle Frankel Davis

    2017-01-01

    Full Text Available Demographic growth, changes in diet, and reliance on first-generation biofuels are increasing the human demand for agricultural products, thereby enhancing the human pressure on global freshwater resources. Recent research on the food-water nexus has highlighted how some major agricultural regions of the world lack the water resources required to sustain current growth trends in crop production. To meet the increasing need for agricultural commodities with limited water resources, the water use efficiency of the agricultural sector must be improved. In this regard, recent work indicates that the often overlooked strategy of changing the crop distribution within presently cultivated areas offers promise. Here we investigate the extent to which water in the United States could be saved while improving yields simply by replacing the existing crops with more suitable ones. We propose crop replacement criteria that achieve this goal while preserving crop diversity, economic value, nitrogen fixation, and food protein production. We find that in the United States, these criteria would greatly improve calorie (+46% and protein (+34% production and economic value (+208%, with 5% water savings with respect to the present crop distribution. Interestingly, greater water savings could be achieved in water-stressed agricultural regions of the US such as California (56% water savings, and other western states.

  18. Water chemistry regimes for VVER-440 units: water chemistry influence on fuel cladding behaviour

    Zmitko, M.

    1999-01-01

    In this lecture next problems of water chemistry influence on fuel cladding behaviour for VVER-440 units are presented: primary coolant technologies; water chemistry specification and control; fuel integrity considerations; zirconium alloys cladding corrosion (corrosion versus burn-up; water chemistry effect; crud deposition; hydrogen absorption; axial offset anomaly); alternatives for the primary coolant regimes

  19. Produced water volumes and management practices in the United States.

    Clark, C. E.; Veil, J. A. (Environmental Science Division)

    2009-09-01

    Produced water volume generation and management in the United States are not well characterized at a national level. The U.S. Department of Energy (DOE) asked Argonne National Laboratory to compile data on produced water associated with oil and gas production to better understand the production volumes and management of this water. The purpose of this report is to improve understanding of produced water by providing detailed information on the volume of produced water generated in the United States and the ways in which produced water is disposed or reused. As the demand for fresh water resources increases, with no concomitant increase in surface or ground water supplies, alternate water sources, like produced water, may play an important role. Produced water is water from underground formations that is brought to the surface during oil or gas production. Because the water has been in contact with hydrocarbon-bearing formations, it contains some of the chemical characteristics of the formations and the hydrocarbons. It may include water from the reservoir, water previously injected into the formation, and any chemicals added during the production processes. The physical and chemical properties of produced water vary considerably depending on the geographic location of the field, the geologic formation, and the type of hydrocarbon product being produced. Produced water properties and volume also vary throughout the lifetime of a reservoir. Produced water is the largest volume by-product or waste stream associated with oil and gas exploration and production. Previous national produced water volume estimates are in the range of 15 to 20 billion barrels (bbl; 1 bbl = 42 U.S. gallons) generated each year in the United States (API 1988, 2000; Veil et al. 2004). However, the details on generation and management of produced water are not well understood on a national scale. Argonne National Laboratory developed detailed national-level information on the volume of produced

  20. Representation and preservation of the water-energy dose unit

    Roos, M.

    1992-01-01

    To represent the water-energy dose unit for high-energy photon and electron radiation, the chemical procedure was expanded into a fundamental measuring technique, and established as a primary normal measuring device of the Federal Republic of Germany. In addition, the water-energy calorimetric dosemeter, a definition measuring method, is being developed which seems to be destined for making a contribution, over the longer term, to reducing measuring uncertainties in dosimetry. (orig./DG) [de

  1. High resolution production water footprints of the United States

    Marston, L.; Yufei, A.; Konar, M.; Mekonnen, M.; Hoekstra, A. Y.

    2017-12-01

    The United States is the largest producer and consumer of goods and services in the world. Rainfall, surface water supplies, and groundwater aquifers represent a fundamental input to this economic production. Despite the importance of water resources to economic activity, we do not have consistent information on water use for specific locations and economic sectors. A national, high-resolution database of water use by sector would provide insight into US utilization and dependence on water resources for economic production. To this end, we calculate the water footprint of over 500 food, energy, mining, services, and manufacturing industries and goods produced in the US. To do this, we employ a data intensive approach that integrates water footprint and input-output techniques into a novel methodological framework. This approach enables us to present the most detailed and comprehensive water footprint analysis of any country to date. This study broadly contributes to our understanding of water in the US economy, enables supply chain managers to assess direct and indirect water dependencies, and provides opportunities to reduce water use through benchmarking.

  2. Contribution of Nutrient Pollution to Water Scarcity in the Water-Rich Northeastern United States

    Hale, R. L.; Lopez, C.; Vorosmarty, C. J.

    2015-12-01

    Most studies of water stress focus on water-scarce regions such as drylands. Yet, even water-rich regions can be water stressed due to local water withdrawals that exceed supply or due to water pollution that makes water unusable. The northeastern United States (NE) is a water-rich region relative to the rest of the country, as it concentrates about 50% of total renewable water of the country. Yes the NE features relatively high water withdrawals, ~50 km3/yr, for thermo-power generation, agriculture, and industry, as well as to support a human population of about 70 million. At the same time, rivers and streams in the NE suffer from nutrient pollution, largely from agricultural and urban land uses. We asked: to what extent is the NE water stressed, and how do water withdrawals and water quality each contribute to water scarcity across the NE? We used information on county-level water withdrawals and runoff to calculate a water scarcity index (WSI) for 200 hydrologic units across the NE from 1987 to 2002. We used data on surface water concentrations of nitrogen to calculate the additional water necessary to dilute surface water pollution to weak, moderate, and strong water quality standards derived from the literature. Only considering withdrawals, we found that approximately 10% of the NE was water stressed. Incorporating a moderate water quality standard, 25% of the NE was water stressed. We calculated a dilution burden by sectors of water users and found that public utilities faced 41% of the total dilution burden for the region, followed by irrigation users at 21%. Our results illustrate that even water rich regions can experience water stress and even scarcity, where withdrawals exceed surface water supplies. Water quality contributes to water stress and can change the spatial patterns of water stress across a region. The common approach to address scarcity has required the use of inter-basin water transfers, or in the case of water quality-caused scarcity

  3. Methods for purifying carbon materials

    Dailly, Anne [Pasadena, CA; Ahn, Channing [Pasadena, CA; Yazami, Rachid [Los Angeles, CA; Fultz, Brent T [Pasadena, CA

    2009-05-26

    Methods of purifying samples are provided that are capable of removing carbonaceous and noncarbonaceous impurities from a sample containing a carbon material having a selected structure. Purification methods are provided for removing residual metal catalyst particles enclosed in multilayer carbonaceous impurities in samples generate by catalytic synthesis methods. Purification methods are provided wherein carbonaceous impurities in a sample are at least partially exfoliated, thereby facilitating subsequent removal of carbonaceous and noncarbonaceous impurities from the sample. Methods of purifying carbon nanotube-containing samples are provided wherein an intercalant is added to the sample and subsequently reacted with an exfoliation initiator to achieve exfoliation of carbonaceous impurities.

  4. Performance of Canadian commercial nuclear units and heavy water plants

    Woodhead, L.W.; Ingolfsrud, L.J.

    The operating history of Canadian commercial CANDU type reactors, i.e. Pickering generating station-A, is described. Capacity factors and unit energy costs are analyzed in detail. Equipment performance highlights are given. The performance of the two Canadian heavy water plants is described and five more are under construction or planned. (E.C.B.)

  5. Effect of different water management strategies on water and contaminant fluxes in Doncaster, United Kingdom.

    Rueedi, J; Cronin, A A; Moon, B; Wolf, L; Hoetzl, H

    2005-01-01

    In Europe, large volumes of public water supply come from urban aquifers and so efficient urban water management and decision tools are essential to maintain quality of life both in terms of health, personal freedom and environment. In the United Kingdom, this issue gained increased importance with the last year's low volumes of groundwater replenishment that resulted in increased water shortages all over the country. An urban water volume and quality model (UVQ) was applied to a suburb of Doncaster (United Kingdom) to assess the current water supply system and to compare it with new potential scenarios of water management. The initial results show considerable changes in both water and solute fluxes for some scenarios and rather limited changes for others. Changing impermeable roads and paved areas to permeable areas, for example, would lead to higher infiltration rates that may be welcome from a water resources viewpoint but less so from a water quality point of view due to high concentrations of heavy metals. The biggest impact on water quality and quantity leaving the system through sewer, storm water and infiltration system was clearly obtained by re-using grey water from kitchen, bathroom and laundry for irrigation and toilet flush. The testing of this strategy led to lower volumes and higher concentrations of sewerage, a considerable decrease in water consumption and an increase in groundwater recharge. The scenarios were tested neither in terms of costs nor social acceptance for either water supplier or user.

  6. Estimated use of water in the United States, 1960

    MacKichan, K.A.; Kammerer, J.C.

    1961-01-01

    The estimated overage withdrawal use of water in the United States during 1960 was almost 270,000 mgd (million gallons per day), exclusive of water used to develop water power. This estimated use amounts to about 1,500 gpd (galIons per day) per capita. An additional 2,000,000 mgd were used to develop waterpower.Withdrawal use of water requires that the water be removed from the ground or diverted from a stream or lake. In this report the use is divided into five types: public supplies, rural, irrigation, self-supplied industrial, and waterpower. Consumptive use of water is the quantity discharged to the atmosphere or incorporated in the products of the process in which it was used. Only 61,000 mgd of the 270,000 mgd withdrawn was consumed.Of the water withdrawn in 1960, 220,000 mgd (including irrigation conveyance losses) was taken from surface sources and 47,000 from underground sources. Withdrawal of water for uses other than waterpower has increased 12 percent since 1955. The amount of water used for generation of waterpower has! increased 33 percent since 1955. The use of saline water was almost twice as great in 1960 as in 1955.The upper limit of our water supply is the average annual runoff, nearly 1,200,000 mgd. The supply in 1960 was depleted by 61,000 mgd, the amount of water consumed. However, a large part of the water withdrawn but not consumed was deteriorated in quality.

  7. Monosaccharides as Versatile Units for Water-Soluble Supramolecular Polymers.

    Leenders, Christianus M A; Jansen, Gijs; Frissen, Martijn M M; Lafleur, René P M; Voets, Ilja K; Palmans, Anja R A; Meijer, E W

    2016-03-18

    We introduce monosaccharides as versatile water-soluble units to compatibilise supramolecular polymers based on the benzene-1,3,5-tricarboxamide (BTA) moiety with water. A library of monosaccharide-based BTAs is evaluated, varying the length of the alkyl chain (hexyl, octyl, decyl and dodecyl) separating the BTA and saccharide units, as well as the saccharide units (α-glucose, β-glucose, α-mannose and α-galactose). In all cases, the monosaccharides impart excellent water compatibility. The length of the alkyl chain is the determining factor to obtain either long, one-dimensional supramolecular polymers (dodecyl spacer), small aggregates (decyl spacer) or molecularly dissolved (octyl and hexyl) BTAs in water. For the BTAs comprising a dodecyl spacer, our results suggest that a cooperative self-assembly process is operative and that the introduction of different monosaccharides does not significantly change the self- assembly behaviour. Finally, we investigate the potential of post-assembly functionalisation of the formed supramolecular polymers by taking advantage of dynamic covalent bond formation between the monosaccharides and benzoxaboroles. We observe that the supramolecular polymers readily react with a fluorescent benzoxaborole derivative permitting imaging of these dynamic complexes by confocal fluorescence microscopy. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. 33 CFR 2.38 - Waters subject to the jurisdiction of the United States; waters over which the United States has...

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Waters subject to the jurisdiction of the United States; waters over which the United States has jurisdiction. 2.38 Section 2.38 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY GENERAL JURISDICTION...

  9. Change of secondary water regime of Paks NPP. Change of secondary water regime at Unit 2

    Doma, A.; Patek, G.; Pinter, T.; Bajari, M.; Tilky, P.

    2001-01-01

    The installation of high pH water regime during the 17th cycle of Unit 2 aimed to decrease the amount of transportation inlet of erosion-corrosion products (magnitude) in feedwater to SGs. The resolution of OAH-NBI permitting the installation ordained to make an evaluation of the process. The main conclusions and results are discussed. The high pH water regime proved to be adequate in the case of Unit 2 as well, similarly to Units 3, 4 and 1. (R.P.)

  10. Control of water infiltration into near surface LLW disposal units

    O'Donnell, E.; Ridky, R.W.; Schulz, R.K.

    1989-01-01

    Water infiltration to buried waste is the prime problem of concern in designing waste disposal units for the humid areas. Conventional compacted clay layers (resistance layer barriers) have been subject to failure by subsidence and by permeability increases brought about by plant roots. A clay barrier with a rock cover sans plants is being investigated. Also a combination of a resistive layer overlying a conductive layer is being investigated. Laboratory studies indicate that this approach can be very effective and field evaluations are underway. However, it must be noted that subsidence will negate the effectiveness of any buried layer barriers. A surface barrier (bioengineering management) has been valuated in the field and found to be very effective in preventing water entry into waste disposal units. This surface barrier is easily repairable if damaged by subsidence and could be the system of choice under active subsidence conditions

  11. Estimated use of water in the United States in 1970

    Murray, Charles Richard; Reeves, E. Bodette

    1972-01-01

    Estimates of water use in the United States in 1970 indicate that an average of about 370 bgd (billion gallons per day)about 1,800 gallons per capita per day--was withdrawn for the four principal off-channel uses which are (1) public-supply (for domestic, commercial, and industrial uses), (2) rural (domestic and livestock), (3) irrigation, and (4) self-supplied industrial (including thermoelectric power). In 1970, withdrawals for these uses exceeded by 19 percent the 310 bgd estimated for 1965. Increases in the various categories of off-channel water use since 1965 were: approximately 25 percent for self-supplied industry (mainly in electric-utility thermoelectric plants), 13 percent for public supplies, 13 percent for rural supplies, and 8 percent for irrigation. Industrial water withdrawals included 54 bgd of saline water, a 20 percent increase in 5 years. The fifth principal withdrawal use, hydroelectric power (an in-channel use), amounted to 2,800 bgd, a 5-year increase of 22 percent. In computing total withdrawals, recycling within a plant (reuse) is not counted, but withdrawal of the same water by a downstream user (cumulative withdrawals) is counted. The quantity of fresh water consumed--that is, water made unavailable for further possible withdrawal because of evaporation, incorporation in crops and manufactured products, and other causes--was estimated to average 87 bgd for 1970, an increase of about 12 percent since 1965.

  12. Dental unit water lines decontamination with the aid of nanotechnology

    Rashmi Paramashivaiah; M.L.V. Prabhuji; Roopalakshmi Narayanan

    2016-01-01

    Aim: This article reviews the issue of dental unit waterline (DUWL) contamination which affects all the clinical and hospital settings. The contaminating microorganisms commonly isolated from these settings and the most pathogenic among them have serious consequences. Over the years several measures are inculcated for decontamination of water, their advantages and shortcomings have been addressed. Options using nanotechnology which are available in the market are described briefly. Materi...

  13. The water needs for LDV transportation in the United States

    King, Carey W.; Webber, Michael E.; Duncan, Ian J.

    2010-01-01

    Concern over increased demand for petroleum, reliable fuel supply, and global climate change has resulted in the US government passing new Corporate Average Fuel Economy standards and a Renewable Fuels Standard. Consequently, the fuel mix for light duty vehicle (LDV) travel in the United States will change over the coming years. This paper explores the embodied water consumption and withdrawal associated with two projections for future fuel use in the US LDV sector. This analysis encompasses conventional and unconventional fossil fuels, corn ethanol, cellulosic ethanol, soy biodiesel, electricity, and hydrogen. The existing mandate in the US to blend ethanol into gasoline had effectively committed 3300 billion liters of irrigation water in 2005 (approximately 2.4% of US 2005 fresh water consumption) for producing fuel for LDVs. With current irrigation practices, fuel processing, and electricity generation, it is estimated that by 2030, approximately 14,000 billion liters of water per year will be consumed and 23,000-27,000 billion liters withdrawn to produce fuels used in LDVs. Irrigation for biofuels dominates projected water usage for LDV travel, but other fuels (coal to liquids, oil shale, and electricity via plug-in hybrid vehicles) will also contribute appreciably to future water consumption and withdrawal, especially on a regional basis. (author)

  14. Purified oleosins at air-water interfaces

    Nikiforidis, C.V.; Ampatzidis, C.; Lalou, S.; Scholten, E.; Karapantsios, T.D.; Kiosseoglou, V.

    2013-01-01

    Oleosins are low molecular mass proteins that are distinguished from other proteins for their extended central hydrophobic domain which covers almost half of its entity. For this work, they were extracted from isolated maize germ oil bodies. The purification steps included washing with diethylether

  15. Estimating irrigation water use in the humid eastern United States

    Levin, Sara B.; Zarriello, Phillip J.

    2013-01-01

    Accurate accounting of irrigation water use is an important part of the U.S. Geological Survey National Water-Use Information Program and the WaterSMART initiative to help maintain sustainable water resources in the Nation. Irrigation water use in the humid eastern United States is not well characterized because of inadequate reporting and wide variability associated with climate, soils, crops, and farming practices. To better understand irrigation water use in the eastern United States, two types of predictive models were developed and compared by using metered irrigation water-use data for corn, cotton, peanut, and soybean crops in Georgia and turf farms in Rhode Island. Reliable metered irrigation data were limited to these areas. The first predictive model that was developed uses logistic regression to predict the occurrence of irrigation on the basis of antecedent climate conditions. Logistic regression equations were developed for corn, cotton, peanut, and soybean crops by using weekly irrigation water-use data from 36 metered sites in Georgia in 2009 and 2010 and turf farms in Rhode Island from 2000 to 2004. For the weeks when irrigation was predicted to take place, the irrigation water-use volume was estimated by multiplying the average metered irrigation application rate by the irrigated acreage for a given crop. The second predictive model that was developed is a crop-water-demand model that uses a daily soil water balance to estimate the water needs of a crop on a given day based on climate, soil, and plant properties. Crop-water-demand models were developed independently of reported irrigation water-use practices and relied on knowledge of plant properties that are available in the literature. Both modeling approaches require accurate accounting of irrigated area and crop type to estimate total irrigation water use. Water-use estimates from both modeling methods were compared to the metered irrigation data from Rhode Island and Georgia that were used to

  16. Statistical modeling of dental unit water bacterial test kit performance.

    Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E

    2007-01-01

    While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.

  17. Identifying future electricity-water tradeoffs in the United States

    Sovacool, Benjamin K.; Sovacool, Kelly E.

    2009-01-01

    Researchers for the electricity industry, national laboratories, and state and federal agencies have begun to argue that the country could face water shortages resulting from the addition of thermoelectric power plants, but have not attempted to depict more precisely where or how severe those shortages will be. Using county-level data on rates of population growth collected from the US Census Bureau, utility estimates of future planned capacity additions in the contiguous United States reported to the US Energy Information Administration, and scientific estimates of anticipated water shortages provided from the US Geologic Survey and National Oceanic and Atmospheric Administration, this paper highlights the most likely locations of severe shortages in 22 counties brought about by thermoelectric capacity additions. Within these areas are some 20 major metropolitan regions where millions of people live. After exploring the electricity-water nexus and explaining the study's methodology, the article then focuses on four of these metropolitan areas - Houston, Texas; Atlanta, Georgia; Las Vegas, Nevada; New York, New York - to deepen an understanding of the water and electricity challenges they may soon be facing. It concludes by identifying an assortment of technologies and policies that could respond to these electricity-water tradeoffs.

  18. Control of water infiltration into near surface LLW disposal units

    Schulz, R.K.; Ridky, R.W.; O'Donnell, E.

    1992-10-01

    The project objective is to assess means for controlling waste infiltration through waste disposal unit covers in humid regions. Experimental work is being performed in large scale lysimeters (70inch x 45inch x lOinch) at Beltsville, MD and results of the assessment are applicable to disposal of LLW, uranium mill tailings, hazardous waste, and sanitary landfills. Three concepts are under investigation: (1) resistive layer barrier, (2) conductive layer barrier, and bioengineering water management. The resistive layer barrier consists of compacted earth (clay). The conductive layer barrier is a special case of the capillary barrier and it requires a flow layer (e.g. fine sandy loam) over a capillary break. As long as unsaturated conditions am maintained water is conducted by the flow layer to below the waste. This barrier is most efficient at low flow rates and is thus best placed below a resistive layer barrier. Such a combination of the resistive layer over the conductive layer barrier promises to be highly effective provided there is no appreciable subsidence. Bioengineering water management is a surface cover that is designed to accommodate subsidence. It consists of impermeable panels which enhance run-off and limit infiltration. Vegetation is planted in narrow openings between panels to transpire water from below the panels. TWs system has successfully dewatered two lysimeters thus demonstrating that this procedure could be used for remedial action (''drying out'') existing water-logged disposal sites at low cost

  19. Identifying future electricity-water tradeoffs in the United States

    Sovacool, Benjamin K. [Energy Governance Program, Centre on Asia and Globalisation, Lee Kuan Yew School of Public Policy, National University of Singapore (Singapore); Sovacool, Kelly E. [Department of Geography, Virginia Polytechnic Institute and State University, Blacksburg, VA (United States)

    2009-07-15

    Researchers for the electricity industry, national laboratories, and state and federal agencies have begun to argue that the country could face water shortages resulting from the addition of thermoelectric power plants, but have not attempted to depict more precisely where or how severe those shortages will be. Using county-level data on rates of population growth collected from the US Census Bureau, utility estimates of future planned capacity additions in the contiguous United States reported to the US Energy Information Administration, and scientific estimates of anticipated water shortages provided from the US Geologic Survey and National Oceanic and Atmospheric Administration, this paper highlights the most likely locations of severe shortages in 22 counties brought about by thermoelectric capacity additions. Within these areas are some 20 major metropolitan regions where millions of people live. After exploring the electricity-water nexus and explaining the study's methodology, the article then focuses on four of these metropolitan areas - Houston, Texas; Atlanta, Georgia; Las Vegas, Nevada; New York, New York - to deepen an understanding of the water and electricity challenges they may soon be facing. It concludes by identifying an assortment of technologies and policies that could respond to these electricity-water tradeoffs. (author)

  20. Lessons learned from the SONGS Unit 1 water hammer event

    Chiu, C.

    1987-01-01

    On November 21, 1985, a water hammer event occurred in horizontal feedwater line B at San Onofre Nuclear Generation Site (SONGS) Unit 1. The SONGS Unit 1 is a three-loop pressurized water reactor designed by Westinghouse Electric Corp. The event was initiated by a differential current trip on the bus of auxiliary transformer C. The root cause of the event was a simultaneous failure of five check valves in the feedwater system. Two of them are located downstream of the feedwater pump, and three of them are located further downstream and on the lines to the steam generators. The failure mechanism was determined to be flow-induced vibration, which caused repeated impact between the disk stud and the disk stop. The water hammer occurred in feedwater line B during the refilling of feedwater lines A, B, and C with auxiliary feedwater. The thermal-hydraulic process to initiate the water hammer and the reason that the water hammer only happened in line B have been fully investigated and explained. A root cause analysis after the event was prompted to answer the following two questions: (1) why did these five check valves fail at that time and not in the preceding 15 yr? (2) why did only these five check valves fail? The scope of the root cause analysis involves an investigation of the valve vibration characteristics, plant operation history, and the maintenance history of the valves. The paper answers these two questions, after a brief study of the vibration characteristics of a check valve

  1. Estimated use of water in the United States in 2015

    Dieter, Cheryl A.; Maupin, Molly A.; Caldwell, Rodney R.; Harris, Melissa A.; Ivahnenko, Tamara I.; Lovelace, John K.; Barber, Nancy L.; Linsey, Kristin S.

    2018-06-19

    Water use in the United States in 2015 was estimated to be about 322 billion gallons per day (Bgal/d), which was 9 percent less than in 2010. The 2015 estimates put total withdrawals at the lowest level since before 1970, following the same overall trend of decreasing total withdrawals observed from 2005 to 2010. Freshwater withdrawals were 281 Bgal/d, or 87 percent of total withdrawals, and saline-water withdrawals were 41.0 Bgal/d, or 13 percent of total withdrawals. Fresh surface-water withdrawals (198 Bgal/d) were 14 percent less than in 2010, and fresh groundwater withdrawals (82.3 Bgal/day) were about 8 percent greater than in 2010. Saline surface-water withdrawals were 38.6 Bgal/d, or 14 percent less than in 2010. Total saline groundwater withdrawals in 2015 were 2.34 Bgal/d, mostly for mining use.Thermoelectric power and irrigation remained the two largest uses of water in 2015, and total withdrawals decreased for thermoelectric power but increased for irrigation. With­drawals in 2015 for thermoelectric power were 18 percent less and withdrawals for irrigation were 2 percent greater than in 2010. Similarly, other uses showed reductions compared to 2010, specifically public supply (–7 percent), self-supplied domestic (–8 percent), self-supplied industrial (–9 percent), and aquaculture (–16 percent). In addition to irrigation (2 percent), mining (1 percent) reported larger withdrawals in 2015 than in 2010. Livestock withdrawals remained essentially the same in 2015 compared to 2010 (0 percent change). Thermoelectric power, irrigation, and public-supply withdrawals accounted for 90 percent of total withdrawals in 2015.Withdrawals for thermoelectric power were 133 Bgal/d in 2015 and represented the lowest levels since before 1970. Surface-water withdrawals accounted for more than 99 percent of total thermoelectric-power withdrawals, and 72 percent of those surface-water withdrawals were from freshwater sources. Saline surface-water withdrawals for

  2. Process for purifying zirconium sponge

    Abodishish, H.A.M.; Kimball, L.S.

    1992-01-01

    This patent describes a Kroll reduction process wherein a zirconium sponge contaminated with unreacted magnesium and by-product magnesium chloride is produced as a regulus, a process for purifying the zirconium sponge. It comprises: distilling magnesium and magnesium chloride from: a regulus containing a zirconium sponge and magnesium and magnesium chloride at a temperature above about 800 degrees C and at an absolute pressure less than about 10 mmHg in a distillation vessel to purify the zirconium sponge; condensing the magnesium and the magnesium chloride distilled from the zirconium sponge in a condenser; and then backfilling the vessel containing the zirconium sponge and the condenser containing the magnesium and the magnesium chloride with a gas; recirculating the gas between the vessel and the condenser to cool the zirconium sponge from above about 800 degrees C to below about 300 degrees C; and cooling the recirculating gas in the condenser containing the condensed magnesium and the condensed magnesium chloride as the gas cools the zirconium sponge to below about 300 degrees C

  3. 33 CFR 328.5 - Changes in limits of waters of the United States.

    2010-07-01

    ... OF THE ARMY, DEPARTMENT OF DEFENSE DEFINITION OF WATERS OF THE UNITED STATES § 328.5 Changes in... drainage may remove an area from waters of the United States. Man-made changes may affect the limits of...

  4. Methods for Purifying Enzymes for Mycoremediation

    Cullings, Kenneth W. (Inventor); DeSimone, Julia C. (Inventor); Paavola, Chad D. (Inventor)

    2014-01-01

    A process for purifying laccase from an ectomycorrhizal fruiting body is disclosed. The process includes steps of homogenization, sonication, centrifugation, filtration, affinity chromatography, ion exchange chromatography, and gel filtration. Purified laccase can also be separated into isomers.

  5. Dental unit water lines decontamination with the aid of nanotechnology.

    Paramashivaiah, Rashmi; Prabhuji, M L V; Narayanan, Roopalakshmi

    2016-01-01

    This article reviews the issue of dental unit waterline (DUWL) contamination which affects all the clinical and hospital settings. The contaminating microorganisms commonly isolated from these settings and the most pathogenic among them have serious consequences. Over the years several measures are inculcated for decontamination of water, their advantages and shortcomings have been addressed. Options using nanotechnology which are available in the market are described briefly. A manual and electronic search was conducted. Google and PubMed were searched for relevant material from studies up to 2013. Medical Subject Headings words looked for were "Nanotechnology," "Water purification," and "Biofilms." Reviewed findings were summarized by topic, using the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement for reporting. Seventy articles were shortlisted for articles pertaining to our topic of discussion. A systematic approach was followed by two independent reviewers and included eligibility criteria for study inclusion, data extraction, data synthesis, and drawing of conclusion. Dental waterline contamination is widespread in any type of dental setting having serious implications on clinicians and patients alike, especially elderly and immune-compromised. Hence, international bodies like center for disease and control and American Dental Association have come up with stringent measures for maintenance of water quality. A gamut of procedures has been tried to overcome this problem ranging from chlorinated products, water filters to the usage of distilled water. The use of nanoemulsions, nanofilters, nanomembranes, etc., and their applicability for routine usage is discussed. Biofilm formation in DUWLs is inevitable with the subsequent release of part of microbiota into the otherwise sterile dental settings. These consequences can be quite serious on clinicians and dental patients. Though conventional measures in water decontamination have

  6. Endurance Pump Test with MIL-PRF-83282 Hydraulic Fluid, Purified with Malabar Purifier

    Sharma, Shashi

    2004-01-01

    .... Endurance aircraft hydraulic pump tests under carefully controlled conditions were previously conducted using hydraulic fluid purified with a rotating-disk and vacuum type purifier, the portable...

  7. Estimated Use of Water in the United States in 1985

    Solley, Wayne B.; Merk, Charles F.; Pierce, Robert R.

    1988-01-01

    Water withdrawals in the United States during 1985 were estimated to average 399,000 million gallons per day (Mgal/d) of freshwater and saline water for offstream uses--10 percent less than the 1980 estimate. Average per-capita use for all offstream uses was 1,650 gallons per day (gal/d) of freshwater and saline water combined and 1,400 gal/d of freshwater alone. Offstream water-use categories are classified in this report as public supply, domestic, commercial, irrigation, livestock, industrial, mining, and thermoelectric power. During 1985, public-supply withdrawals were estimated to be 36,500 Mgal/d, and self-supplied withdrawals were estimated as follows: domestic, 3,320 Mgal/d: commercial, 1,230 Mgal/d; irrigation, 137,000 Mgal/d: livestock, 4,470 Mgal/d; industrial, 25,800 Mgal/d; mining, 3,440 Mgal/d; and thermoelectric power, 187,000 Mgal/d. Water use for hydroelectric power generation, the only instream use compiled in this report, was estimated to be 3,050,000 Mgal/d during 1985, or 7 percent less than during 1980. This is in contrast to an increasing trend that persisted from 1950 to 1980. Estimates of withdrawals by source indicate that, during 1985, total surface-water withdrawals were 325,000 Mgal/d, or 10 percent less than during 1980, and total ground-water withdrawals were 74,000 Mgal/d, or 12 percent less than during 1980. Total saline-water withdrawals during 1985 were 60,300 Mgal/d, or 16 percent less than during 1980; most was saline surface water. Reclaimed sewage averaged about 579 Mgal/d during 1985, or 22 percent more than during 1980. Total freshwater consumptive use was estimated to be 92,300 Mgal/d during 1985, or 9 percent less than during 1980. Consumptive use by irrigation accounted for the largest part of consumptive use during 1985 and was estimated to be 73,800 Mgal/d. A comparison of total withdrawals (fresh and saline) by State indicates that 37 States and Puerto Rico had less water withdrawn for offstream uses during 1985 than

  8. Water-temperature data acquisition activities in the United States

    Pauszek, F.H.

    1972-01-01

    Water Data Coordination, U.S. Geological Survey, and published in the "Catalog of Information on Water Data, Index to Water Quality Section, Edition 1970." This is one of four indexes, each of which is a separate section of the Catalog. Three of the indexes, "Index to Water-Quality Section," "Index to Surface-Water Section," and "Index to Ground-.Water Stations," contain information on data acquired on a recurrent basis at specific locations for a period of 3 years or more. The fourth section, "Index to Areal Investigations and Miscellaneous Activities," is concerned with specific projects or shorter-term data activities that involve field or laboratory measurements or observations not included in any other section of the Catalog. The Catalog is a record of activities throughout the country (and in some places along the international border between the United States and Canada) conducted by Federal and non-Federal agencies engaged in the acquisition of water data and who furnish such information for presentation in the Catalog. The Catalog itself is an outgrowth of an assignment to the Department of the Interior and in turn to the Geological Survey, by the Office of Management and Budget, through the medium of OMB Circular A-67. This Circular states in part that one of the assigned responsibilities will be maintenance of a "central catalog of information on...water data and on Federal activities being planned or conducted to acquire such data." As an extension of this activity, non-Federal agencies are solicited to participate in the program. In this report, information is presented by means of tables and illustrations preceded by brief explanations. It includes the agencies collecting the data, the number of stations located on surface and ground waters where temperature measurements are made, the distribution of stations by States and by the 21 regions of the Water Resources Council (WRC) (a Federal agency created in accordance with the Water Resources Planning Act of

  9. The United States advanced light water reactor (USALWR) development program

    Stahlkopf, K.E.; Noble, D.M.; Devine, J.C. Jr.; Sugnet, W.R.

    1987-01-01

    For the United States Nuclear Power industry to remain viable, it must be prepared to meet the expected need for a new generation capacity in the late 90s with an improved reactor system. The best hope of meeting this requirement is with revolutionary changes to current LWR systems through simplification and re-evaluation of safety and operational design margins. In addition, the grid characteristics and the difficulty in raising capital for large projects indicate the smaller light water reactors (600 MWe) may play an important role in the next generation. A cooperative and coordinated program between EPRI, U.S. DOE, the major architect engineers, nuclear steam supply vendors, and the NRC in the U.S. has been undertaken with four major goals in mind

  10. The United States Advanced Light Water reactor (USALWR) development program

    Stahlkopf, K.E.; Noble, D.M.; Devine, Jr.J.C.; Sugnet, W.R.

    1987-01-01

    For the United States Nuclear power industry to remain viable, it must be prepared to meet the expected need for a new generation capacity in the late 90s with an improved reactor system. The best hope of meeting this requirement is with revolutionary changes to current LWR systems through simplification and re-evaluation of safety and operational design margins. In addition, the grid characteristics and the difficulty in raising capital for large projects indicate the smaller light water reactors (600 MWe) may play an important role in the next generation. A cooperative and coordinated program between EPRI, U.S. DOE, the major architect engineers, nuclear steam supply vendors, and the NRC in the U.S. has been undertaken with four major goals in mind. (author)

  11. Water Supply. Fire Service Certification Series. Unit FSCS-FF-9-80.

    Pribyl, Paul F.

    This training unit on water supply is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4-hour unit is to assist the firefighter in the proper use of water supplies and the understanding of the…

  12. Potential Implications of Approaches to Climate Change on the Clean Water Rule Definition of "Waters of the United States".

    Faust, Derek R; Moore, Matthew T; Emison, Gerald Andrews; Rush, Scott A

    2016-05-01

    The 1972 Clean Water Act was passed to protect chemical, physical, and biological integrity of United States' waters. The U.S. Environmental Protection Agency and U.S. Army Corps of Engineers codified a new "waters of the United States" rule on June 29, 2015, because several Supreme Court case decisions caused confusion with the existing rule. Climate change could affect this rule through connectivity between groundwater and surface waters; floodplain waters and the 100-year floodplain; changes in jurisdictional status; and sea level rise on coastal ecosystems. Four approaches are discussed for handling these implications: (1) "Wait and see"; (2) changes to the rule; (3) use guidance documents; (4) Congress statutorily defining "waters of the United States." The approach chosen should be legally defensible and achieved in a timely fashion to provide protection to "waters of the United States" in proactive consideration of scientifically documented effects of climate change on aquatic ecosystems.

  13. An Overview of Marine Biodiversity in United States Waters

    Fautin, Daphne; Dalton, Penelope; Incze, Lewis S.; Leong, Jo-Ann C.; Pautzke, Clarence; Rosenberg, Andrew; Sandifer, Paul; Sedberry, George; Tunnell, John W.; Abbott, Isabella; Brainard, Russell E.; Brodeur, Melissa; Eldredge, Lucius G.; Feldman, Michael; Moretzsohn, Fabio; Vroom, Peter S.; Wainstein, Michelle; Wolff, Nicholas

    2010-01-01

    Marine biodiversity of the United States (U.S.) is extensively documented, but data assembled by the United States National Committee for the Census of Marine Life demonstrate that even the most complete taxonomic inventories are based on records scattered in space and time. The best-known taxa are those of commercial importance. Body size is directly correlated with knowledge of a species, and knowledge also diminishes with distance from shore and depth. Measures of biodiversity other than species diversity, such as ecosystem and genetic diversity, are poorly documented. Threats to marine biodiversity in the U.S. are the same as those for most of the world: overexploitation of living resources; reduced water quality; coastal development; shipping; invasive species; rising temperature and concentrations of carbon dioxide in the surface ocean, and other changes that may be consequences of global change, including shifting currents; increased number and size of hypoxic or anoxic areas; and increased number and duration of harmful algal blooms. More information must be obtained through field and laboratory research and monitoring that involve innovative sampling techniques (such as genetics and acoustics), but data that already exist must be made accessible. And all data must have a temporal component so trends can be identified. As data are compiled, techniques must be developed to make certain that scales are compatible, to combine and reconcile data collected for various purposes with disparate gear, and to automate taxonomic changes. Information on biotic and abiotic elements of the environment must be interactively linked. Impediments to assembling existing data and collecting new data on marine biodiversity include logistical problems as well as shortages in finances and taxonomic expertise. PMID:20689852

  14. An overview of marine biodiversity in United States waters

    Fautin, Daphne G.; Delton, Penelope; Incze, Lewis S.; Leong, Jo-Ann C.; Pautzke, Clarence; Rosenberg, Andrew A.; Sandifer, Paul; Sedberry, George R.; Tunnell, John W.; Abbott, Isabella; Brainard, Russell E.; Brodeur, Melissa; Eldredge, Lucius G.; Feldman, Michael; Moretzsohn, Fabio; Vroom, Peter S.; Wainstein, Michelle; Wolff, Nicholas

    2010-01-01

    Marine biodiversity of the United States (U.S.) is extensively documented, but data assembled by the United States National Committee for the Census of Marine Life demonstrate that even the most complete taxonomic inventories are based on records scattered in space and time. The best-known taxa are those of commercial importance. Body size is directly correlated with knowledge of a species, and knowledge also diminishes with distance from shore and depth. Measures of biodiversity other than species diversity, such as ecosystem and genetic diversity, are poorly documented. Threats to marine biodiversity in the U.S. are the same as those for most of the world: overexploitation of living resources; reduced water quality; coastal development; shipping; invasive species; rising temperature and concentrations of carbon dioxide in the surface ocean, and other changes that may be consequences of global change, including shifting currents; increased number and size of hypoxic or anoxic areas; and increased number and duration of harmful algal blooms. More information must be obtained through field and laboratory research and monitoring that involve innovative sampling techniques (such as genetics and acoustics), but data that already exist must be made accessible. And all data must have a temporal component so trends can be identified. As data are compiled, techniques must be developed to make certain that scales are compatible, to combine and reconcile data collected for various purposes with disparate gear, and to automate taxonomic changes. Information on biotic and abiotic elements of the environment must be interactively linked. Impediments to assembling existing data and collecting new data on marine biodiversity include logistical problems as well as shortages in finances and taxonomic expertise.

  15. 3 CFR - Designation of Officers of the United States Section, International Boundary and Water Commission...

    2010-01-01

    ... 3 The President 1 2010-01-01 2010-01-01 false Designation of Officers of the United States Section, International Boundary and Water Commission, United States and Mexico To Act as the Commissioner of the United... States and Mexico To Act as the Commissioner of the United States Section Memorandum for the Commissioner...

  16. Hydrogen purifier module with membrane support

    A hydrogen purifier utilizing a hydrogen-permeable membrane to purify hydrogen from mixed gases containing hydrogen is disclosed. Improved mechanical support for the permeable membrane is described, enabling forward or reverse differential pressurization of the membrane, which further stabilizes the membrane from wrinkling upon hydrogen uptake.

    2012-07-24

    A hydrogen purifier utilizing a hydrogen-permeable membrane to purify hydrogen from mixed gases containing hydrogen is disclosed. Improved mechanical support for the permeable membrane is described, enabling forward or reverse differential pressurization of the membrane, which further stabilizes the membrane from wrinkling upon hydrogen uptake.

  17. EnviroAtlas - Agricultural Water Demand by 12-Digit HUC for the Conterminous United States

    U.S. Environmental Protection Agency — The national agricultural water demand metric provides insight into the amount of water currently used for agricultural irrigation in the contiguous United States....

  18. EnviroAtlas - Watershed Index Online Water Mask for the Conterminous United States

    U.S. Environmental Protection Agency — This data layer represents all surface water features in the United States. This grid was created by combining water features identified in two sources, the Cropland...

  19. Arsenic in Ground Water of the United States

    ... Team More Information Arsenic in groundwater of the United States Arsenic in groundwater is largely the result of ... Gronberg (2011) for updated arsenic map. Featured publications United States Effects of human-induced alteration of groundwater flow ...

  20. Appropriation System: water rights in the western United States; water pollution problems peculiar to the uranium industry

    Worcester, T.E.

    1976-01-01

    The legal framework surrounding water rights acquisition and usage in the western United States and the steps which should be taken in analyzing potential sources of water are dealt with. Some of the applicable water pollution control laws and regulations are discussed briefly

  1. Forests, Water and People: Drinking water supply and forest lands in the Northeast and Midwest United States, June 2009

    Martina Barnes; Albert Todd; Rebecca Whitney Lilja; Paul Barten

    2009-01-01

    Forests are critically important to the supply of clean drinking water in the Northeast and Midwest portion of the United States. In this part of the country more than 52 million people depend on surface water supplies that are protected in large part by forested lands. The public is generally unaware of the threats to their water supplies or the connection between...

  2. Integrity Assessment of Essential Service Water System of Ulchin unit 1 and 2

    Lee, Sun Ki; Lee, Sang Kook; Jeong, Il Suk; Song, Taek Ho; Kwon, Jong Ju; Hong, Seong Yul; Lee, Jin Hwan

    2005-01-01

    Because of circulating water filtration system(CFI) and essential service water system(SEC) of Ulchin unit 1 and 2 were designed by commonness water intake structure, circulating water filtration system is managed by quality grade Q class. In this study, circulating water filtration system (CFI) examined revision possibility from present quality grade Q class to R class. It is proving that the operation of essential service water system (SEC) is always available regardless CFI conditions

  3. 76 FR 3159 - Purified Carboxymethylcellulose From Finland, Mexico, Netherlands, and Sweden

    2011-01-19

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1084-1087 (Review)] Purified Carboxymethylcellulose From Finland, Mexico, Netherlands, and Sweden AGENCY: United States International Trade Commission. ACTION: Revised schedule for the subject reviews. DATES: Effective Date: January 7, 2011. FOR FURTHER...

  4. Trends in Drinking Water Nitrate Violations Across the United States

    Drinking water maximum contaminant levels (MCL) are established by the U.S. EPA in order to protect human health. Since 1975, public water suppliers across the U.S. have reported violations of the MCL to the national Safe Drinking Water Information System (SDWIS). Nitrate is on...

  5. Ground-Water Availability in the United States

    Reilly, Thomas E.; Dennehy, Kevin F.; Alley, William M.; Cunningham, William L.

    2008-01-01

    Ground water is among the Nation's most important natural resources. It provides half our drinking water and is essential to the vitality of agriculture and industry, as well as to the health of rivers, wetlands, and estuaries throughout the country. Large-scale development of ground-water resources with accompanying declines in ground-water levels and other effects of pumping has led to concerns about the future availability of ground water to meet domestic, agricultural, industrial, and environmental needs. The challenges in determining ground-water availability are many. This report examines what is known about the Nation's ground-water availability and outlines a program of study by the U.S. Geological Survey Ground-Water Resources Program to improve our understanding of ground-water availability in major aquifers across the Nation. The approach is designed to provide useful regional information for State and local agencies who manage ground-water resources, while providing the building blocks for a national assessment. The report is written for a wide audience interested or involved in the management, protection, and sustainable use of the Nation's water resources.

  6. Automated Water-Purification System

    Ahlstrom, Harlow G.; Hames, Peter S.; Menninger, Fredrick J.

    1988-01-01

    Reverse-osmosis system operates and maintains itself with minimal human attention, using programmable controller. In purifier, membranes surround hollow cores through which clean product water flows out of reverse-osmosis unit. No chemical reactions or phase changes involved. Reject water, in which dissolved solids concentrated, emerges from outer membrane material on same side water entered. Flow controls maintain ratio of 50 percent product water and 50 percent reject water. Membranes expected to last from 3 to 15 years.

  7. Water quality status and trends in the United States

    Larsen, Matthew C.; Hamilton, Pixie A.; Werkheiser, William H.; Ahuja, Satinder

    2013-01-01

    Information about water quality is vital to ensure long-term availability and sustainability of water that is safe for drinking and recreation and suitable for industry, irrigation, fish, and wildlife. Protecting and enhancing water quality is a national priority, requiring information on water-quality status and trends, progress toward clean water standards, continuing problems, and emerging challenges. In this brief review, we discuss U.S. Geological Survey assessments of nutrient pollution, pesticides, mixtures of organic wastewater compounds (known as emerging contaminants), sediment-bound contaminants (like lead and DDT), and mercury, among other contaminants. Additionally, aspects of land use and current and emerging challenges associated with climate change are presented. Climate change must be considered, as water managers continue their efforts to maintain sufficient water of good quality for humans and for the ecosystem.

  8. Purifying hydrocarbons in the gaseous stage

    1937-02-01

    Gaseous tar oils are subjected, at temperatures of 320 to 380/sup 0/C, to the action of a mixture of activated carbon mixed with powdered metal which removes the sulfur contamination from the substance to be purified.

  9. Method for purifying bidentate organophosphorus compounds

    Schulz, W.W.

    1977-01-01

    Bidentate organophosphorus compounds useful for extracting actinide elements from acidic nuclear waste solutions are purified of undesirable acidic impurities by contacting the compounds with ethylene glycol which preferentially extracts the impurities found in technical grade bidentate compounds

  10. Water use for electricity in the United States: an analysis of reported and calculated water use information for 2008

    Averyt, K; Meldrum, J; Macknick, J; Newmark, R; Rogers, J; Madden, N; Fisher, J

    2013-01-01

    Water use by the electricity sector represents a significant portion of the United States water budget (41% of total freshwater withdrawals; 3% consumed). Sustainable management of water resources necessitates an accurate accounting of all water demands, including water use for generation of electricity. Since 1985, the Department of Energy (DOE) Energy Information Administration (EIA) has collected self-reported data on water consumption and withdrawals from individual power generators. These data represent the only annual collection of water consumption and withdrawals by the electricity sector. Here, we compile publically available information into a comprehensive database and then calculate water withdrawals and consumptive use for power plants in the US. In effect, we evaluate the quality of water use data reported by EIA for the year 2008. Significant differences between reported and calculated water data are evident, yet no consistent reason for the discrepancies emerges. (letter)

  11. National Water Model assessment for water management needs over the Western United States.

    Viterbo, F.; Thorstensen, A.; Cifelli, R.; Hughes, M.; Johnson, L.; Gochis, D.; Wood, A.; Nowak, K.; Dahm, K.

    2017-12-01

    The NOAA National Water Model (NWM) became operational in August 2016, providing the first ever, real-time distributed high-resolution forecasts for the continental United States. Since the model predictions occur at the CONUS scale, there is a need to evaluate the NWM in different regions to assess the wide variety and heterogeneity of hydrological processes that are included (e.g., snow melting, ice freezing, flash flooding events). In particular, to address water management needs in the western U.S., a collaborative project between the Bureau of Reclamation, NOAA, and NCAR is ongoing to assess the NWM performance for reservoir inflow forecasting needs and water management operations. In this work, the NWM is evaluated using different forecast ranges (short to medium) and retrospective historical runs forced by North American Land Data Assimilation System (NLDAS) analysis to assess the NWM skills over key headwaters watersheds in the western U.S. that are of interest to the Bureau of Reclamation. The streamflow results are analyzed and compared with the available observations at the gauge sites, evaluating different NWM operational versions together with the already existing local River Forecast Center forecasts. The NWM uncertainty is also considered, evaluating the propagation of the precipitation forcing uncertainties in the resulting hydrograph. In addition, the possible advantages of high-resolution distributed output variables (such as soil moisture, evapotranspiration fluxes) are investigated, to determine the utility of such information for water managers in terms of watershed characteristics in areas that traditionally have not had any forecast information. The results highlight the NWM's ability to provide high-resolution forecast information in space and time. As anticipated, the performance is best in regions that are dominated by natural flows and where the model has benefited from efforts toward parameter calibration. In highly regulated basins, the

  12. Study of water quality improvements during riverbank filtration at three midwestern United States drinking water utilities

    Weiss, W.; Bouwer, E.; Ball, W.; O'Melia, C.; Lechevallier, M.; Arora, H.; Aboytes, R.; Speth, T.

    2003-04-01

    Riverbank filtration (RBF) is a process during which surface water is subjected to subsurface flow prior to extraction from wells. During infiltration and soil passage, surface water is subjected to a combination of physical, chemical, and biological processes such as filtration, dilution, sorption, and biodegradation that can significantly improve the raw water quality (Tufenkji et al, 2002; Kuehn and Mueller, 2000; Kivimaki et al, 1998; Stuyfzand, 1998). Transport through alluvial aquifers is associated with a number of water quality benefits, including removal of microbes, pesticides, total and dissolved organic carbon (TOC and DOC), nitrate, and other contaminants (Hiscock and Grischek, 2002; Tufenkji et al., 2002; Ray et al, 2002; Kuehn and Mueller, 2000; Doussan et al, 1997; Cosovic et al, 1996; Juttner, 1995; Miettinen et al, 1994). In comparison to most groundwater sources, alluvial aquifers that are hydraulically connected to rivers are typically easier to exploit (shallow) and more highly productive for drinking water supplies (Doussan et al, 1997). Increased applications of RBF are anticipated as drinking water utilities strive to meet increasingly stringent drinking water regulations, especially with regard to the provision of multiple barriers for protection against microbial pathogens, and with regard to tighter regulations for disinfection by-products (DBPs), such as trihalomethanes (THMs) and haloacetic acids (HAAs). In the above context, research was conducted to document the water quality benefits during RBF at three major river sources in the mid-western United States, specifically with regard to DBP precursor organic matter and microbial pathogens. Specific objectives were to: 1. Evaluate the merits of RBF for removing/controlling DBP precursors and certain other drinking water contaminants (e.g. microorganisms). 2. Evaluate whether RBF can improve finished drinking water quality by removing and/or altering natural organic matter (NOM) in a

  13. Load factor trends in light water reactor units

    Lehtinen, E.A.

    1990-01-01

    The Technical Research Centre of Finland follows up and analyses nuclear power plant availability performances worldwide. The results of a trend study for the load factors of the LWR units have been updated to the end of 1987. The whole operating history, in the sense of the annual and cumulative load factors achieved by all the Western commercial LWR units until the end of 1987, has been taken into consideration. Some trends in the load factors have been identified by using an exponential regression model developed. The LWR units form quite an inhomogeneous population with respect to their age, technical characteristics, site country as well as cumulative load factors achieved. The cumulative load factors achieved by all the LWR units until the end of 1987 are presented individually in the scattergrams

  14. [Complex technology for water and wastewater disinfection and its industrial realization in prototype unit].

    Arakcheev, E N; Brunman, V E; Brunman, M V; Konyashin, A V; Dyachenko, V A; Petkova, A P

    Usage of complex automated electrolysis unit for drinking water disinfection and wastewater oxidation and coagulation is scoped, its ecological and energy efficiency is shown. Properties of technological process of anolyte production using membrane electrolysis of brine for water disinfection in municipal pipelines and potassium ferrate production using electrochemical dissolution of iron anode in NaOH solution for usage in purification plants are listed. Construction of modules of industrial prototype for anolyte and ferrate production and applied aspects of automation of complex electrolysis unit are proved. Results of approbation of electrolytic potassium ferrate for drinking water disinfection and wastewater, rain water and environmental water oxidation and coagulation are shown.

  15. Impacts of multiple stresses on water demand and supply across the southeastern United States

    Ge Sun; Steven G. McNulty; Jennifer A. Moore Myers; Erika C. Cohen

    2008-01-01

    Assessment of long-term impacts of projected changes in climate, population, and land use and land cover on regional water resource is critical to the sustainable development of the southeastern United States. The objective of this study was to fully budget annual water availability for water supply (precipitation ) evapotranspiration + groundwater supply + return flow...

  16. Design of a unit to produce hot distilled water for the same power consumption as a water heater

    Bambenek, R. A.; Nuccio, P. P.

    1973-01-01

    Unit recovers 97% of water contained in pretreated waste water. Some factors are: cleansing agent prevents fouling of heat transfer surface by highly concentrated waste; absence of dynamic seals reduces required purge gas flow rate; and recycle loop maintains constant flushing process to carry cleansing agent across evaporation surface.

  17. Bottled Water: United States Consumers and Their Perceptions of Water Quality

    Hu, Zhihua; Morton, Lois Wright; Mahler, Robert L.

    2011-01-01

    Consumption of bottled water is increasing worldwide. Prior research shows many consumers believe bottled water is convenient and has better taste than tap water, despite reports of a number of water quality incidents with bottled water. The authors explore the demographic and social factors associated with bottled water users in the U.S. and the relationship between bottled water use and perceptions of the quality of local water supply. They find that U.S. consumers are more likely to report...

  18. Carbon accounting in the United Kingdom water sector: a review.

    Prescott, C

    2009-01-01

    The UK is committed to greenhouse gas (GHG) emission reduction targets and has introduced a number of initiatives to achieve these. Until recently, these targeted energy-intensive industries and, thus, the water sector was not significantly affected. However, from 2010, UK water companies will need to report their emissions under the Carbon Reduction Commitment (CRC). Both Ofwat (the economic regulator for water companies in England and Wales) and the Northern Ireland Authority for Utility Regulation (NIAUR) now require annual reporting of GHG emissions in accordance with both Defra Guidelines and the CRC. Also, carbon impacts must now be factored into all water industry investment planning in England and Wales. Building on existing approaches, the industry has developed standardised carbon accounting methodologies to meet both of these requirements. This process has highlighted gaps in knowledge where further research is needed.

  19. Water reuse practices in the United States and abroad

    Sheikh, B.

    1998-07-01

    Reuse of water reclaimed from waste takes various adaptations in different parts of the globe to accommodate the economic forces underlying water supply constraints and local public health and sanitation conditions. The more developed regions have adopted and enforced the most rigorous water reuse regulations. The strong environmental safeguards adopted and the immense investments made in these countries in wastewater treatment provide for a very high quality of discharged effluent. Unfortunately, high (even adequate) levels of investment in sanitation and environmental protection have been lacking in most of the rest of the world. In the developing nations of the world a de facto brand of water reuse is practiced, generally without the benefit of protective standards of acceptable public health practice. Between the extremes of high standards of public health protection on the one hand, and the unsanitary use of raw sewage on the other, there are wide varieties of uses and treatment levels dictated by and evolved to accommodate the local economy.

  20. Concentration data for anthropogenic organic compounds in ground water, surface water, and finished water of selected community water systems in the United States, 2002-05

    Carter, Janet M.; Delzer, Gregory C.; Kingsbury, James A.; Hopple, Jessica A.

    2007-01-01

    The National Water-Quality Assessment Program of the U.S. Geological Survey began implementing Source Water-Quality Assessments (SWQAs) in 2001 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems (CWSs) in the United States. As used for SWQA studies, source water is the raw (ambient) water collected at the supply well prior to water treatment (for ground water) or the raw (ambient) water collected from the river near the intake (for surface water), and finished water is the water that is treated and ready to be delivered to consumers. Finished water is collected before entering the distribution system. SWQA studies are conducted in two phases, and the objectives of SWQA studies are twofold: (1) to determine the occurrence and, for rivers, seasonal changes in concentrations of a broad list of anthropogenic organic compounds (AOCs) in aquifers and rivers that have some of the largest withdrawals for drinking-water supply (phase 1), and (2) for those AOCs found to occur most frequently in source water, characterize the extent to which these compounds are present in finished water (phase 2). These objectives were met for SWQA studies by collecting ground-water and surface-water (source) samples and analyzing these samples for 258 AOCs during phase 1. Samples from a subset of wells and surface-water sites located in areas with substantial agricultural production in the watershed were analyzed for 19 additional AOCs, for a total of 277 compounds analyzed for SWQA studies. The 277 compounds were classified according to the following 13 primary use or source groups: (1) disinfection by-products; (2) fumigant-related compounds; (3) fungicides; (4) gasoline hydrocarbons, oxygenates, and oxygenate degradates; (5) herbicides and herbicide degradates; (6) insecticides and insecticide degradates; (7) manufacturing additives; (8) organic synthesis compounds; (9) pavement- and

  1. EPA and the Army Corps’ Rule to Define Waters of the United States

    2017-01-05

    ponds as defined in 40 C.F.R. 423.11(m) which also meet the criteria of this definition) are not waters of the United States.d (1) Waste ...treatment systems, including treatment ponds or lagoons, designed to meet the requirements of the Clean Water Act. (1) Waste treatment systems, including...4) Floodplain: The term floodplain means an area bordering inland or coastal waters that was formed by sediment deposition from such water under

  2. A High Rated Solar Water Distillation Unit for Solar Homes

    Abhishek Saxena

    2016-01-01

    Full Text Available India is presently focusing on complete utilization of solar energy and saving fossil fuels, which are limited. Various solar energy systems like solar cookers, solar water heaters, solar lanterns, solar PV lights, and solar lamps are continuously availing by the people of India at a low cost and on good subsidies. Apart from this, India is a solar energy promising country with a good number of solar homes (carrying solar energy systems in its various locations. The present paper focuses on a unique combination of solar dish cooker (SDC and solar water heater (SWH to produce distilled water with a high distillate and a high daily productivity. The procedure has been discussed on the basis of experimental testing to produce distilled water by combining an evacuated type SWH and a SDC. Experimentation has been carried out in MIT, Moradabad (longitude, 28.83°N, and latitude, 78.78°E by developing the same experimental setup on behalf of solar homes. The daily productivity of distilled water was found around 3.66 litres per day in full sunshine hours for an approximated pH value of 7.7 and a ppm value of 21. The payback period (PBP has been estimated around 1.16 years of the present system.

  3. Cernavoda unit2 recirculated cooling water system transient analysis

    Nita, I. P.; Pancef, R.

    2015-01-01

    The paper is an approach to calculate the response of Cernavoda NPP Unit 2 RCW System to transient regimes during normal and abnormal regimes. Then one started to analyse the system response to reactor trip on class III and IV of power, LOCA on class IV of power, LOCA on class III power, LOIA on class IV of power, and LOIA on class III power. Moreover, one analysed the system transient due to requirement of changeover of a RCW operating pump, planned and unplanned changeover. This is the first transient approach to this system that took in consideration all building of the system, obtaining a very large system model, with over 900 pipe, 4 pumps, 50 consumers, 21 control valves. The changeover procedure was required to be analysed in order to change the nominal operating mode for Unit 2, from current 2 pumps in operation to 3 pump operations during summer operating mode. (authors)

  4. Spatial distribution of water supply in the coterminous United States

    Thomas C. Brown; Michael T. Hobbins; Jorge A. Ramirez

    2008-01-01

    Available water supply across the contiguous 48 states was estimated as precipitation minus evapotranspiration using data for the period 1953-1994. Precipitation estimates were taken from the Parameter- Elevation Regressions on Independent Slopes Model (PRISM). Evapotranspiration was estimated using two models, the Advection-Aridity model and the Zhang model. The...

  5. High-Resolution Water Footprints of Production of the United States

    Marston, Landon; Ao, Yufei; Konar, Megan; Mekonnen, Mesfin M.; Hoekstra, Arjen Y.

    2018-03-01

    The United States is the largest producer of goods and services in the world. Rainfall, surface water supplies, and groundwater aquifers represent a fundamental input to economic production. Despite the importance of water resources to economic activity, we do not have consistent information on water use for specific locations and economic sectors. A national, spatially detailed database of water use by sector would provide insight into U.S. utilization and dependence on water resources for economic production. To this end, we calculate the water footprint of over 500 food, energy, mining, services, and manufacturing industries and goods produced in the United States. To do this, we employ a data intensive approach that integrates water footprint and input-output techniques into a novel methodological framework. This approach enables us to present the most detailed and comprehensive water footprint analysis of any country to date. This study broadly contributes to our understanding of water in the U.S. economy, enables supply chain managers to assess direct and indirect water dependencies, and provides opportunities to reduce water use through benchmarking. In fact, we find that 94% of U.S. industries could reduce their total water footprint more by sourcing from more water-efficient suppliers in their supply chain than they could by converting their own operations to be more water-efficient.

  6. Design and operational parameters of transportable supercritical water oxidation waste destruction unit

    McFarland, R.D.; Brewer, G.R.; Rofer, C.K.

    1991-12-01

    Supercritical water oxidation (SCWO) is the destruction of hazardous waste by oxidation in the presence of water at temperatures and pressures above its critical point. A 1 gal/h SCWO waste destruction unit (WDU) has been designed, built, and operated at Los Alamos National Laboratory. This unit is transportable and is intended to demonstrate the SCWO technology on wastes at Department of Energy sites. This report describes the design of the WDU and the preliminary testing phase leading to demonstration

  7. Benefits of greenhouse gas mitigation on the supply, management, and use of water resources in the United States

    Strzepek, Kenneth; Neumann, J.; SMith, J.; Martinich, J.; Boehlert, B.; Hejazi, M.; Henderson, J.; Wobus, C.; Jones, R.; Calvin, K.; Johnson, D.; Monier, Erwan; Strzepek, J.; Yoon, J.-H.

    2013-01-01

    Climate change impacts on water resources in the United States are likely to be far-reaching and substantial because the water is integral to climate, and the water sector spans many parts of the economy. This paper estimates impacts and damages from five water resource-related models addressing runoff, drought risk, economics of water supply/demand, water stress, and flooding damages. The models differ in the water system assessed, spatial scale, and unit of assessment, but together provide ...

  8. Water lancing of Bruce-A Unit 3 and 4 steam generators

    Puzzuoli, F.V.; Murchie, B.; Allen, S.

    1995-01-01

    During the Bruce-A 1993 Unit 4 and 1994 Unit 3 outages, three water lancing operations were carried out along with chemical cleaning as part of the station boiler refurbishment program. The water lancing activities focused on three boiler areas.. 1) support plates to clean partially or completely blocked broach holes and prevent boiler water level oscillations, 2) hot leg U-bend supports (HLUBS) to remove deposits contributing to boiler tube stress corrosion cracking (SCC) and 3) tube sheets to dislodge sludge piles that potentially threaten boiler tube integrity and to flush out post chemical cleaning insoluble residues. The combination of water lancing and chemical cleaning effectively reduced broach hole blockage from up to 100% to 0-10% or less. As a result, boilers in Units 3 and 4 will operate for some time to come without concerns over water level oscillations. However, deposits remained in most tube support plate land areas. (author)

  9. Water Quality Monitoring: An Environmental Studies Unit for Biology 20/30. Teacher's Guide.

    Alberta Environment, Edmonton. Environmental Education Resources Branch.

    The objective of this environmental studies unit is to establish a water quality monitoring project for high school students in Alberta while simultaneously providing a unit which meets the objectives of the Biology 20 program (and which may also be used in Biology 10 and 30). Through this project, students assist in the collection,…

  10. Water Quality Monitoring: An Environmental Studies Unit for Biology 20/30. Student Manual.

    Alberta Environment, Edmonton. Environmental Education Resources Branch.

    The objective of this environmental studies unit is to establish a water quality monitoring project for high school students in Alberta while simultaneously providing a unit which meets the objectives of the Biology 20 program (and which may also be used in Biology 10 and 30). Through this project, students assist in the collection,…

  11. Dental unit water lines decontamination with the aid of nanotechnology

    Rashmi Paramashivaiah

    2016-01-01

    Conclusions: Biofilm formation in DUWLs is inevitable with the subsequent release of part of microbiota into the otherwise sterile dental settings. These consequences can be quite serious on clinicians and dental patients. Though conventional measures in water decontamination have been partly successful, the quest for more foolproof methods has led to the use of latest technology, i.e., nanotechnology. The most practical option has to be chosen based on the ease of their usage.

  12. Aqueous treatment of water-sensitive paper objects: capillary unit, blotter wash or paraprint wash?

    Schalkx, H.; Iedema, P.; Reissland, B.; van Velzen, B.

    2011-01-01

    Blotter washing andwashing with the capillary unit are both methods used for aqueoustreatment of water-sensitive paper objects. The challenge of thistreatment is to remove water-soluble products while keeping thewater-sensitive medium in its place. In this article the two methodsare compared, along

  13. Water Quality Assessment of the Buffalo River, Arkansas, United States

    Bolin, K. L.; Ruhl, L. S.

    2017-12-01

    The Buffalo River was established as a National River by the U.S. Congress in 1972, and runs approximately 150 miles from Newton County, Arkansas to Baxter County where it joins the White River. The Buffalo National River is the one of the last free flowing rivers in the continental U.S. with a rich cultural and political history surrounding it. The geology surrounding the river can be characterized by its karst environment, which has led to the many caves, depressions, and sinkholes found along the river. Karst environments are more susceptible to groundwater pollution so drainage from septic systems is a major concern for towns along the river. There are also numerous abandoned mines in the Buffalo River watershed, especially in the Rush area, which was mined for lead and zinc. Additionally, an increase in livestock production in the area is also a concern for increased nitrate and phosphate, along with fertilizer runoff from agricultural areas. The purpose of this study was to determine the water quality changes along the Buffalo River from human and environmental influences. Samples at six different locations along the river were collected along with parameters such as pH, conductivity, salinity, and temperature during several trips in the summer of 2017. Water samples were analyzed for cations and anions by IC, trace metals by ICPMS, and Escherichia coli with agar plate colony counts. The results were used to map geochemical changes in the Buffalo River watershed, and calculate enrichment factors of constituents (like nitrate, phosphate, and trace elements) as the water flowed downstream.

  14. Adapt or Drown - Can the United States Chart a Safe Course Through the Troubled Waters of Energy Security

    2010-04-01

    the cost of meat and dairy products. One solution, algae, has been discussed for decreasing the dependency of biodiesel production on crops—a...and maize/corn (United States). Ethanol is produced by fermenting sugars. Corn grain is processed to remove the sugar in wet and dry mills (by...crushing, soaking, and/or chemical treatment), the sugar is fermented , and the resulting mix is distilled and purified to obtain anhydrous ethanol. Major

  15. Modeling water and hydrogen networks with partitioning regeneration units

    W.M. Shehata

    2015-03-01

    Full Text Available Strict environment regulations in chemical and refinery industries lead to minimize resource consumption by designing utility networks within industrial process plants. The present study proposed a superstructure based optimization model for the synthesis of water and hydrogen networks with partitioning regenerators without mixing the regenerated sources. This method determines the number of partitioning regenerators needed for the regeneration of the sources. The number of the regenerators is based on the number of sources required to be treated for recovery. Each source is regenerated in an individual partitioning regenerator. Multiple regeneration systems can be employed to achieve minimum flowrate and costs. The formulation is linear in the regenerator balance equations. The optimized model is applied for two systems, partitioning regeneration systems of the fixed outlet impurity concentration and partitioning regeneration systems of the fixed impurity load removal ratio (RR for water and hydrogen networks. Several case studies from the literature are solved to illustrate the ease and applicability of the proposed method.

  16. Primary Water Chemistry Control at Units of Paks Nuclear Power Plant

    Schunk, J.; Pinter, G. Patek T.; Tilky, P.; Doma, A. [Paks Nuclear Power Plant Co. Ltd., Paks (Hungary); Osz, J. [Budapest University of Technology and Economics, Budapest (Hungary)

    2013-03-15

    The primary water chemistry of the four identical units of Paks Nuclear Power Plant has been developed based on Western type PWR units, taking into consideration some Russian modifications. The political changes in the 1990s have also influenced the water chemistry specifications and directions. At PWR units the transition operational modes have been developed while in case of WWER units - in lack of central uniform regulation - this question has become the competence and responsibility of each individual plant. This problem has resulted in separate water chemistry developments with a considerable time delay. The need for lifetime extensions worldwide has made the development of startup and shutdown chemistry procedures extremely important, since they considerably influence the long term and safe operation of plants. The uniformly structured limit value system, the principles applied for the system development, and the logic schemes for actions to be taken are discussed in the paper, both for normal operation and transition modes. (author)

  17. Disinfection aboard cruise liners and naval units: formation of disinfection by-products using chlorine dioxide in different qualities of drinking water.

    Ufermann, Petra; Petersen, Hauke; Exner, Martin

    2011-12-01

    The world-wide deployment of cruise liners and naval units has caused an increased need for the disinfection of drinking water. The main cause for this is the unknown quality of drinking water in foreign harbours--besides the formation of bio-films due to the climatically disadvantageous conditions in the operational area. Water conduits on board are currently disinfected with calcium hypochlorite in case of microbiological contamination. Chemical and physical analyses after disinfection with calcium hypochlorite have shown that organic by-products consisting of trihalomethanes develop in considerable amounts during disinfection. Furthermore, the method is susceptible to handling errors and thus often leads to insufficient disinfection results. Hitherto, the use of other disinfection methods allowed by government regulations, especially chlorine dioxide, is not widely spread. Unlike disinfection with calcium hypochlorite, chlorine dioxide does not lead to the formation of trihalomethanes. Typical disinfection by-products (DBP) are the anions chlorite and chlorate, which are formed in oxidative processes. The formation conditions of these anions have not yet been elucidated. For this reason, the probability of the generation of inorganic by-products after disinfection with chlorine dioxide has been determined, and their occurrence in drinking water on board has been examined with respect to a possible correlation between water quality and the formation of chlorate and chlorite. Therefore, a chromatographic method was developed and validated in order to determine the periodical development of chlorate and chlorite from chorine dioxide in purified water at different pH-values as well as in actual drinking water samples from water conduits on board. The formation of the by-products chlorite and chlorate after disinfection with chlorine dioxide is influenced neither by pH-value nor by chemical properties of the disinfected water. Considering the examined conditions

  18. Energy Savings and Breakeven Costs for Residential Heat Pump Water Heaters in the United States

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burch, Jay [National Renewable Energy Lab. (NREL), Golden, CO (United States); Merrigan, Tim [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ong, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-07-01

    Heat pump water heaters (HPWHs) have recently re-emerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, NREL performed simulations of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern United States. When replacing an electric water heater, the HPWH is likely to break even in California, the southern United States, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  19. Weekend Warriors for Water: Combating Water Scarcity in West Africa with United States Army National Guard and Reserve Forces

    2017-06-09

    vulnerable to “conflict and instability from political, social, economic , and environmental challenges” (United States Africa Command 2017). The...improve regional stability , which in turn increases economic , political, and social development. RC deployments to support water scarcity missions can...Capacity DOD Department of Defense DOS Department of State ECOWAS Economic Community of West African States FHA Foreign Humanitarian Assistance

  20. Steroidogenesis in amlodipine treated purified Leydig cells

    Latif, Rabia, E-mail: rabialatif08@hotmail.com [Department of Physiology, Army Medical College, National University of Sciences and Technology, Islamabad (Pakistan); Lodhi, Ghulam Mustafa, E-mail: drmustafa786@gmail.com [Department of Physiology, Wah Medical College, Wah (Pakistan); Hameed, Waqas, E-mail: waqham@hotmail.com [Department of Physiology, Rehman Medical College, Peshawar (Pakistan); Aslam, Muhammad, E-mail: professormaslam@yahoo.com [Department of Physiology, Shifa College of Medicine, Islamabad (Pakistan)

    2012-01-01

    Drugs have been shown to adversely affect male fertility and recently anti-hypertensive drugs were added to the list. The anti-fertility effects of amlodipine, a calcium channel blocker, are well-illustrated in in vivo experiments but lack an in vitro proof. The present study was designed to experimentally elucidate the effects of amlodipine on Leydig cell steroidogenesis and intracellular calcium in vitro. Leydig cells of Sprague–Dawley rats were isolated and purified by Percoll. Cells were incubated for 3 h with/without amlodipine in the presence/absence of LH, dbcAMP, Pregnenolone and 25-Hydroxycholesterol. Cytosolic calcium was measured in purified Leydig cells by fluorometric technique. The results showed significantly reduced (P < 0.05) steroidogenesis and intracellular calcium in amlodipine exposed rats. The site of amlodipine induced steroidogenic inhibition seems to be prior to the formation of Pregnenolone at the level of StAR protein. -- Highlights: ► Inhibition of steroidogenesis in isolated and purified Leydig cells by amlodipine. ► Site of inhibition was before Pregnenolone formation, at the level of StAR protein. ► Inhibition of LH stimulated rise in cytosolic calcium by amlodipine.

  1. Uncertainty analysis of light water reactor unit fuel pin cells

    Kamerow, S.; Ivanov, K., E-mail: sln107@PSU.EDU, E-mail: kni1@PSU.EDU [Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, PA (United States); Moreno, C. Arenas, E-mail: cristina.arenas@UPC.EDU [Department of Physics and Nuclear Engineering, Technical University of Catalonia, Barcelona (Spain)

    2011-07-01

    The study explored the calculation of uncertainty based on available covariance data and computational tools. Uncertainty due to temperature changes and different fuel compositions are the main focus of this analysis. Selected unit fuel pin cells were analyzed according to the OECD LWR UAM benchmark specifications. Criticality and uncertainty analyses were performed using TSUNAMI-1D sequence in SCALE 6.0. It was found that uncertainties increase with increasing temperature while k{sub eff} decreases. This increase in the uncertainty is due to the increase in sensitivity of the largest contributor of uncertainty, namely nuclide reaction {sup 238}U (n, gamma). The sensitivity grew larger as the capture cross-section of {sup 238}U expanded due to Doppler broadening. In addition, three different compositions (UOx, MOx, and UOxGd{sub 2}O{sub 3}) of fuel cells were analyzed. It showed a remarkable increase in uncertainty in k{sub eff} for the case of the MOx fuel cell and UOxGd{sub 2}O{sub 3} fuel cell. The increase in the uncertainty of k{sub eff} in UOxGd{sub 2}O{sub 3} fuel was nearly twice of that in MOx fuel and almost four times the amount in UOx fuel. The components of the uncertainties in k{sub eff} in each case were examined and it was found that the neutron-nuclide reaction of {sup 238}U, mainly (n,n'), contributed the most to the uncertainties in the cases of MOx and UOxGd{sub 2}O{sub 3}. At higher energy, the covariance coefficient matrix of {sup 238}U (n,n') to {sup 238}U (n,n') and {sup 238}U (n,n') cross-section showed very large values. Further, examination of the UOxGd{sub 2}O{sub 3} case found that the {sup 238}U (n,n') became the dominant contributor to the uncertainty because most of the thermal neutrons in the cell were absorbed by Gadolinium in UOxGd{sub 2}O{sub 3} case and thus shifting the neutron spectrum to higher energy. For the MOx case on other hand, {sup 239}Pu has a very strong absorption cross-section at low energy

  2. Enhancing Groundwater Cost Estimation with the Interpolation of Water Tables across the United States

    Rosli, A. U. M.; Lall, U.; Josset, L.; Rising, J. A.; Russo, T. A.; Eisenhart, T.

    2017-12-01

    Analyzing the trends in water use and supply across the United States is fundamental to efforts in ensuring water sustainability. As part of this, estimating the costs of producing or obtaining water (water extraction) and the correlation with water use is an important aspect in understanding the underlying trends. This study estimates groundwater costs by interpolating the depth to water level across the US in each county. We use Ordinary and Universal Kriging, accounting for the differences between aquifers. Kriging generates a best linear unbiased estimate at each location and has been widely used to map ground-water surfaces (Alley, 1993).The spatial covariates included in the universal Kriging were land-surface elevation as well as aquifer information. The average water table is computed for each county using block kriging to obtain a national map of groundwater cost, which we compare with survey estimates of depth to the water table performed by the USDA. Groundwater extraction costs were then assumed to be proportional to water table depth. Beyond estimating the water cost, the approach can provide an indication of groundwater-stress by exploring the historical evolution of depth to the water table using time series information between 1960 and 2015. Despite data limitations, we hope to enable a more compelling and meaningful national-level analysis through the quantification of cost and stress for more economically efficient water management.

  3. Comparison of Advanced Residential Water Heating Technologies in the United States

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Fang, Xia [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wilson, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-05-01

    In this study, gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the United States, installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many pre-existing models were used, new models of condensing and heat pump water heaters were created specifically for this work. In each case modeled, the whole house was simulated along with the water heater to capture any interactions between the water heater and the space conditioning equipment.

  4. Sectoral contributions to surface water stress in the coterminous United States

    Averyt, K; Meldrum, J; Caldwell, P; Sun, G; McNulty, S; Huber-Lee, A; Madden, N

    2013-01-01

    Here, we assess current stress in the freshwater system based on the best available data in order to understand possible risks and vulnerabilities to regional water resources and the sectors dependent on freshwater. We present watershed-scale measures of surface water supply stress for the coterminous United States (US) using the water supply stress index (WaSSI) model which considers regional trends in both water supply and demand. A snapshot of contemporary annual water demand is compared against different water supply regimes, including current average supplies, current extreme-year supplies, and projected future average surface water flows under a changing climate. In addition, we investigate the contributions of different water demand sectors to current water stress. On average, water supplies are stressed, meaning that demands for water outstrip natural supplies in over 9% of the 2103 watersheds examined. These watersheds rely on reservoir storage, conveyance systems, and groundwater to meet current water demands. Overall, agriculture is the major demand-side driver of water stress in the US, whereas municipal stress is isolated to southern California. Water stress introduced by cooling water demands for power plants is punctuated across the US, indicating that a single power plant has the potential to stress water supplies at the watershed scale. On the supply side, watersheds in the western US are particularly sensitive to low flow events and projected long-term shifts in flow driven by climate change. The WaSSI results imply that not only are water resources in the southwest in particular at risk, but that there are also potential vulnerabilities to specific sectors, even in the ‘water-rich’ southeast. (letter)

  5. Unit for wind power plants and water power. Aggregat fuer Windkraftanlagen und Wasserkraft

    Armonies, H.; Armonies, G.

    1983-01-13

    The invention concerns the manufacture and process of kinetic thermal units for wind power plants and water power. It is characterized by the fact that the supporting frame of the unit is made so that it carries the unit shaft bearing and also a fixed flange for a hollow body, pump part, unit shaft pushback device and thermal insulation. The unit shaft running in bearings is made so that it can rotate in the two bearings or a double bearing and can also slide between 2 flanges on the unit shaft in the longitudinal direction of the bearings. The end of the unit shaft projecting beyond the supporting frame is made so that the wind blades, rotors or water turbines can be connected to it by flanges. The rotor shaft can be pressed against a hollow body carrying a liquid by a friction disc. A heat resistant liquid pump is also situated on the supporting frame. It is driven by the unit shaft. (HWJ).

  6. Enhancing the ecological and operational characteristics of water treatment units at TPPs based on baromembrane technologies

    Chichirova, N. D.; Chichirov, A. A.; Filimonova, A. A.; Saitov, S. R.

    2017-12-01

    The innovative baromembrane technologies for water demineralization were introduced at Russian TPPs more than 25 years ago. While being used in the power engineering industry of Russia, these technologies demonstrated certain advantages over the traditional ion-exchange and thermal technologies of makeup water treatment for steam boilers. Water treatment units based on the baromembrane technology are compact, easy to operate, and highly automated. The experience gained from the use of these units shows that their reliability depends directly on preliminary water treatment. The popular water pretreatment technology with coagulation by aluminum oxychloride proved to be inefficient during the seasonal changes of source water quality that occurs at some stations. The use of aluminum coagulant at pH 8 and higher does not ensure the stable and qualitative pretreatment regime: soluble aluminum forms slip on membranes of the ultrafiltration unit, thereby causing pollution and intoxication as well as leading to structural damages or worsening of mechanical properties of the membranes. The problem of increased pH and seasonal changes of the source water quality can be solved by substitution of the traditional coagulant into a new one. To find the most successful coagulant for water pretreatment, experiments have been performed on both qualitative and quantitative analysis of the content of natural organic matters in the Volga water and their structure. We have developed a software program and measured the concentrations of soluble aluminum and iron salts at different pH values of the source water. The analysis of the obtained results has indicated that iron sulfate at pH 6.0-10.2, in contrast to aluminum oxychloride, is not characterized by increased solubility. Thus, the basic process diagrams of water pretreatment based on baromembrane technologies with pretreatment through coagulation by iron salts and wastewater amount reducing from 60-40 to 5-2% have been introduced for

  7. A spatially detailed blue water footprint of the United States economy

    Rushforth, Richard R.; Ruddell, Benjamin L.

    2018-05-01

    This paper quantifies and maps a spatially detailed and economically complete blue water footprint for the United States, utilizing the National Water Economy Database version 1.1 (NWED). NWED utilizes multiple mesoscale (county-level) federal data resources from the United States Geological Survey (USGS), the United States Department of Agriculture (USDA), the US Energy Information Administration (EIA), the US Department of Transportation (USDOT), the US Department of Energy (USDOE), and the US Bureau of Labor Statistics (BLS) to quantify water use, economic trade, and commodity flows to construct this water footprint. Results corroborate previous studies in both the magnitude of the US water footprint (F) and in the observed pattern of virtual water flows. Four virtual water accounting scenarios were developed with minimum (Min), median (Med), and maximum (Max) consumptive use scenarios and a withdrawal-based scenario. The median water footprint (FCUMed) of the US is 181 966 Mm3 (FWithdrawal: 400 844 Mm3; FCUMax: 222 144 Mm3; FCUMin: 61 117 Mm3) and the median per capita water footprint (F'CUMed) of the US is 589 m3 per capita (F'Withdrawal: 1298 m3 per capita; F'CUMax: 720 m3 per capita; F'CUMin: 198 m3 per capita). The US hydroeconomic network is centered on cities. Approximately 58 % of US water consumption is for direct and indirect use by cities. Further, the water footprint of agriculture and livestock is 93 % of the total US blue water footprint, and is dominated by irrigated agriculture in the western US. The water footprint of the industrial, domestic, and power economic sectors is centered on population centers, while the water footprint of the mining sector is highly dependent on the location of mineral resources. Owing to uncertainty in consumptive use coefficients alone, the mesoscale blue water footprint uncertainty ranges from 63 to over 99 % depending on location. Harmonized region-specific, economic-sector-specific consumption coefficients are

  8. Concentration data for anthropogenic organic compounds in groundwater, surface water, and finished water of selected community water systems in the United States, 2002-10

    Carter, Janet M.; Kingsbury, James A.; Hopple, Jessica A.; Delzer, Gregory C.

    2010-01-01

    The National Water-Quality Assessment Program of the U.S. Geological Survey began implementing Source Water-Quality Assessments (SWQAs) in 2001 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems in the United States. As used in SWQA studies, source water is the raw (ambient) water collected at the supply well before water treatment (for groundwater) or the raw (ambient) water collected from the river near the intake (for surface water), and finished water is the water that has been treated and is ready to be delivered to consumers. Finished-water samples are collected before the water enters the distribution system. The primary objective of SWQAs is to determine the occurrence of more than 250 anthropogenic organic compounds in source water used by community water systems, many of which currently are unregulated in drinking water by the U.S. Environmental Protection Agency. A secondary objective is to understand recurrence patterns in source water and determine if these patterns also occur in finished water before distribution. SWQA studies were conducted in two phases for most studies completed by 2005, and in one phase for most studies completed since 2005. Analytical results are reported for a total of 295 different anthropogenic organic compounds monitored in source-water and finished-water samples collected during 2002-10. The 295 compounds were classified according to the following 13 primary use or source groups: (1) disinfection by-products; (2) fumigant-related compounds; (3) fungicides; (4) gasoline hydrocarbons, oxygenates, and oxygenate degradates; (5) herbicides and herbicide degradates; (6) insecticides and insecticide degradates; (7) manufacturing additives; (8) organic synthesis compounds; (9) pavement- and combustion-derived compounds; (10) personal-care and domestic-use products; (11) plant- or animal-derived biochemicals; (12) refrigerants and

  9. Impact of a risk management plan on Legionella contamination of dental unit water.

    Leoni, Erica; Dallolio, Laura; Stagni, Francesca; Sanna, Tiziana; D'Alessandro, Giovanni; Piana, Gabriela

    2015-02-23

    The study aimed to assess the prevalence of Legionella spp. in dental unit waterlines of a dental clinic and to verify whether the microbiological parameters used as indicators of water quality were correlated with Legionella contamination. A risk management plan was subsequently implemented in the dental health care setting, in order to verify whether the adopted disinfection protocols were effective in preventing Legionella colonization. The water delivered from syringes and turbines of 63 dental units operating in a dental clinic, was monitored for counts of the heterotrophic bacteria P. aeruginosa and Legionella spp. (22 °C and 37 °C). At baseline, output water from dental units continuously treated with disinfection products was more compliant with the recommended standards than untreated and periodically treated water. However, continuous disinfection was still not able to prevent contamination by Legionella and P. aeruginosa. Legionella was isolated from 36.4%, 24.3% and 53.3% of samples from untreated, periodically and continuously treated waterlines, respectively. The standard microbiological parameters used as indicators of water quality proved to be unreliable as predictors of the presence of Legionella, whose source was identified as the tap water used to supply the dental units. The adoption of control measures, including the use of deionized water in supplying the dental unit waterlines and the application of a combined protocol of continuous and periodic disinfection, with different active products for the different devices, resulted in good control of Legionella contamination. The efficacy of the measures adopted was mainly linked to the strict adherence to the planned protocols, which placed particular stress on staff training and ongoing environmental monitoring.

  10. Water level measurements for modeling hydraulic properties in the 300-FF-5 and 100 Aggregate Area Operable units

    Campbell, M.D.; McMahon, W.J.; Simpson, K.R.

    1993-04-01

    Pressure transducers connected to dataloggers were used to measure ground water and Columbia River water elevations simultaneously and hourly at 35 locations in the 300-FF-5 Operable Unit and 16 locations in the 100 Aggregate Area Operable Unit on the Hanford Site. Water temperatures were also measured at 12 of these locations. This report details the findings of these studies

  11. Comparison of single-step and two-step purified coagulants from Moringa oleifera seed for turbidity and DOC removal.

    Sánchez-Martín, J; Ghebremichael, K; Beltrán-Heredia, J

    2010-08-01

    The coagulant proteins from Moringa oleifera purified with single-step and two-step ion-exchange processes were used for the coagulation of surface water from Meuse river in The Netherlands. The performances of the two purified coagulants and the crude extract were assessed in terms of turbidity and DOC removal. The results indicated that the optimum dosage of the single-step purified coagulant was more than two times higher compared to the two-step purified coagulant in terms of turbidity removal. And the residual DOC in the two-step purified coagulant was lower than in single-step purified coagulant or crude extract. (c) 2010 Elsevier Ltd. All rights reserved.

  12. Potabilization of brackish water by electrodialysis. Study of natural samples with a laboratory unit

    Sainz Sastre, J. A.; Alonso-Lopez, J.

    1972-01-01

    Potabilization of brackish waters from Ciguela (Toledo) and Riansares (Toledo) rivers, and from wells 1 and 2 at Torre Pacheco (Murcia), as well as of sea water diluted to 5,000 ppm has been studied in process conditions optimized from experiments with synthetic solutions. The study includes: removal of suspended and organic matter, determination of limit current density, power requirements, ion selectivity and daily maximum output of the unit. (Author) 8 refs

  13. Water stress and social vulnerability in the southern United States, 2010-2040

    cassandra Johnson-Gaither; John Schelhas; Wayne Zipperer; Ge Sun; Peter V. Caldwell; Neelam Poudyal

    2014-01-01

    Water scarcities are striking in semiarid, subregions of the Southern United States such as Oklahoma and western Texas (Glennon 2009, Sabo et al. 2010). In Texas, water stress has been a constant concern since the 1950s when the state experienced severe drought conditions (Moore 2005). The nearly 2000-mile Rio Grande River, which forms part of the Texas–Mexico border,...

  14. [Studies on the process of Herba Clinopodii saponins purified with macroporous adsorption resin].

    Zhang, Yi; Yan, Dan; Han, Yumei

    2005-10-01

    To study the technological parameters of the purification process of saponins with macroporous adsorption resin. The adsorptive characteristics and elutive parameters of the process were studied by taking the elutive and purified ratio of saponins as markers. 11.4 ml of the extraction of Herba Clinopodii (crude drugs 0.2 g/ml) was purified with a column of macroporous adsorption resin (phi15 mm x H90 mm, dry weight 2.5 g) and washed with 3BV of distilled water, then eluted with 3BV of 30% ethanol and 3BV of 70% ethanol. Most of saponins were collected in the 70% ethanol. With macroporous adsorption resin adsorbing and purifying,the elutive ratio of saponins is 86.8% and the purity reaches 153.2%. So this process of applying macroporous adsorption resin to adsorb and purify Saponins is feasible.

  15. 1944 Water Treaty Between Mexico and the United States: Present Situation and Future Potential

    Anabel Sánchez

    2006-01-01

    Full Text Available Historically and culturally, water has always been considered to be a critical issue in Mexico- USA agenda. Along the 3 140-km border between Mexico and the United States, there is intense competition over the adequate availability of water. Water uses in urban border areas have continued to increase exponentially due to steadily increasing levels of population growth. Rapid industrialisation and urbanisation have resulted in more intensive patterns of water consumption and use. Agricultural water demands continue to be high. Mexico and the United States have established institutions and agreements to manage and protect rivers in the border region. The Treaty between Mexico and the United States for the Utilisation of Waters of the Colorado and Tijuana Rivers and of the Rio Grande was signed in 1944. With the turn of the century, the growing urban centers along the Rio Grande (Rio Bravo, where the river becomes the international boundary, started increasingly to depend on groundwater. This situation was not specifically addressed in the 1944 Treaty, especially as groundwater use at that time was not so significant.

  16. Water uptake in woody riparian phreatophytes of the southwestern United States: a stable isotope study

    Busch, D.E.; Ingraham, N.L.; Smith, S.D.

    1992-01-01

    Alluvial forest associations are often dominated by woody phreatophytes, plants that are tightly linked to aquifers for water uptake. Anthropogenic hydrological alterations (e.g., water impoundment or diversion) are of clear importance to riparian ecosystem function. Because decreased frequency of flooding and depression of water tables may, in effect, sever riparian plants from their natural water sources, research was undertaken to determine water uptake patterns for the dominant native and introduced woody taxa of riparian plant communities of the southwestern United States. At floodplain study sites along the Bill Williams and lower Colorado Rivers (Arizona, USA), naturally occurring D and 18 O were used to distinguish among potential water sources. Isotopic ratios from potential uptake locations were compared to water extracted from the dominant woody taxa of the study area (Populus fremontii, Salix gooddingii, and Tamarix ramosissima) to elucidate patterns of water absorption. Isotopic composition of water obtained from sapwood cores did not differ significantly from heartwood or branch water, suggesting that heartwood water exchange, stem capacitance, and phloem sap mixing may be inconsequential in actively transpiring Salix and Populus. There was evidence for close hydrologic linkage of river, ground, and soil water during the early part of the growing season. Surface soils exhibited D enrichment due to cumulative exposure to evaporation as the growing season progressed. Isotopic ratios of water extracted from Populus and Salix did not exhibit isotopic enrichment and were not significantly different from groundwater or saturated soil water sources, indicating a phreatophytic uptake pattern. Associations of isotopic ratios with water relations parameters indicated high levels of canopy evaporation and possible use of moisture from unsaturated alluvial soils in addition to groundwater in Tamarix. (author)

  17. The Northeastern United States Energy-Water Nexus: Climate Change Impacts and Alternative Water Management Strategies for the Power Sector

    Miara, A.; Macknick, J.; Vorosmarty, C. J.; Cohen, S. M.; Rosenzweig, B.

    2014-12-01

    The Northeastern United States (NE) relies heavily on thermoelectric power plants (90% of total capacity) to provide electricity to more than 70 million people. This region's power plants require consistent, large volumes of water at sufficiently cold temperatures to generate electricity efficiently, and withdraw approximately 10.5 trillion gallons of water annually. Previous findings indicate that assessments of future electricity pathways must account for water availability, water temperature and the changing climate, as changes in these conditions may limit operational efficiency in the future. To account for such electric system vulnerabilities, we have created a link between an electricity system capacity expansion model (ReEDS) and a hydrologic model that is coupled to a power plant simulation model (FrAMES-TP2M) that allows for a new approach to analyze electricity system development, performance, and environmental impacts. Together, these coupled tools allow us to estimate electricity development and operations in the context of a changing climate and impacts on the seasonal spatial and temporal variability of water resources, downstream thermal effluents that cause plant-to-plant interferences and harm aquatic habitat, economic costs of water conservation methods and associated carbon emissions. In this study, we test and compare a business-as-usual strategy with three alternative water management scenarios that include changes in cooling technologies and water sources utilized for the years 2014-2050. Results of these experiments can provide useful insight into the feasibility of the electricity expansion scenarios in terms of associated water use and thermal impacts, carbon emissions, the cost of generating electricity, and also highlight the importance of accounting for water resources in future power sector planning and performance assessments.

  18. Standard and hydrazine water chemistry in primary circuit of VVER 440 units

    Burclova, J.

    1992-01-01

    Standard ammonia-potassium-boron water chemistry of 8 units with VVER 440 in CSFR is discussed as well as the corrosion product activity in the coolant during steady state and shut-down period and surface activity, dose rate build-up and occupational radiation exposure. Available data on hydrazine application (USSR, Hungary) indicate the possibility of the radiation field decreasing. Nevertheless the detailed analysis of 55 cycles of operation under standard water chemistry in Czechoslovakia allows to expect the comparable results for both water chemistries. (author)

  19. Integrated collector-storage solar water heater with extended storage unit

    Kumar, Rakesh; Rosen, Marc A.

    2011-01-01

    The integrated collector-storage solar water heater (ICSSWH) is one of the simplest designs of solar water heater. In ICSSWH systems the conversion of solar energy into useful heat is often simple, efficient and cost effective. To broaden the usefulness of ICSSWH systems, especially for overnight applications, numerous design modifications have been proposed and analyzed in the past. In the present investigation the storage tank of an ICSSWH is coupled with an extended storage section. The total volume of the modified ICSSWH has two sections. Section A is exposed to incoming solar radiation, while section B is insulated on all sides. An expression is developed for the natural convection flow rate in section A. The inter-related energy balances are written for each section and solved to ascertain the impact of the extended storage unit on the water temperature and the water heater efficiency. The volumes of water in the two sections are optimized to achieve a maximum water temperature at a reasonably high efficiency. The influence is investigated of inclination angle of section A on the temperature of water heater and the angle is optimized. It is determined that a volume ratio of 7/3 between sections A and B yields the maximum water temperature and efficiency in the modified solar water heater. The performance of the modified water heater is also compared with a conventional ICSSWH system under similar conditions.

  20. How Much Water Can We Save by Achieving Renewable Portfolio Standards in the Southwest United States?

    Yuzhen Feng

    2018-03-01

    Full Text Available Electricity in the Southwestern United States is primarily generated with water intensive steam turbines. If energy demand continues to rise this will lead to a further rise in water demand. A comprehensive understanding of water consumption and withdrawal for utility scale generation of electricity is necessary before any improvements in the water efficiency of such systems in arid environments can be made. This study estimated and compared the water usage associated with thermoelectric generation (i.e., natural gas, coal, and solar energy, in the five driest Colorado River Basin states: Utah, New Mexico, Nevada, Arizona, and California. This study also examined and compared each state’s Renewable Portfolio Standards (RPS and how this might impact water savings. Results showed that each state’s current RPS goals would reduce the water that is consumed by the generation of electricity. However, the amount of water savings will vary on a state by state basis. In order to reduce water consumption, replacing thermal electric generation with photovoltaic (PV solar can be significant and should be encouraged. The amount of water saved will vary, however, depending on the state’s choice of coal or natural gas.

  1. Experimental Analysis of Desalination Unit Coupled with Solar Water Lens Concentrator

    Chaithanya, K. K.; Rajesh, V. R.; Suresh, Rahul

    2016-09-01

    The main problem that the world faces in this scenario is shortage of potable water. Hence this research work rivets to increase the yield of desalination system in an economical way. The integration of solar concentrator and desalination unit can project the desired yield, but the commercially available concentrated solar power technologies (CSP) are not economically viable. So this study proposes a novel method to concentrate ample amount of solar radiation in a cost effective way. Water acting as lens is a highlighted technology initiated in this work, which can be a substitute for CSP systems. And water lens can accelerate the desalination process so as to increase the yield economically. The solar irradiance passing through the water will be concentrated at a focal point, and the concentration depends on curvature of water lens. The experimental analysis of water lens makes use of transparent thin sheet, supported on a metallic structure. The Plano convex shape of water lens is developed by varying the volume of water that is being poured on the transparent thin sheet. From the experimental analysis it is inferred that, as the curvature of water lens increases, solar irradiance can be focused more accurately on to the focus and a higher water temperature is obtained inside the solar still.

  2. Optimum returns from greenhouse vegetables under water quality and risk constraints in the United Arab Emirates

    Greenhouses have been used in the United Arab Emirates (UAE) to produce vegetables that contribute toward UAE food security, including offering fresh vegetable produce in the off-season. However, to manage such greenhouses farmers face both technical and environmental limitations (i.e., high water s...

  3. Water and Wastewater Annual Price Escalation Rates for Selected Cities across the United States

    None, None

    2017-10-27

    Pacific Northwest National Laboratory conducted this study for the Federal Energy Management Program to identify trends in annual water and wastewater price escalation rates across the United States. This study can be used to inform the selection of an appropriate escalation rates for inclusion in LCCA.

  4. Storm water control plan for the Lower East Fork Poplar Creek Operable Unit, Oak Ridge, Tennessee

    1996-04-01

    This document provides the Environmental Restoration Program with information about the erosion and sediment control, storm water management, maintenance, and reporting and record keeping practices to be employed during Phase II of the remediation project for the Lower East Fork Poplar Creek (LEFPC) Operable Unit

  5. Method for Estimating Water Withdrawals for Livestock in the United States, 2005

    Lovelace, John K.

    2009-01-01

    Livestock water use includes ground water and surface water associated with livestock watering, feedlots, dairy operations, and other on-farm needs. The water may be used for drinking, cooling, sanitation, waste disposal, and other needs related to the animals. Estimates of water withdrawals for livestock are needed for water planning and management. This report documents a method used to estimate withdrawals of fresh ground water and surface water for livestock in 2005 for each county and county equivalent in the United States, Puerto Rico, and the U.S. Virgin Islands. Categories of livestock included dairy cattle, beef and other cattle, hogs and pigs, laying hens, broilers and other chickens, turkeys, sheep and lambs, all goats, and horses (including ponies, mules, burros, and donkeys). Use of the method described in this report could result in more consistent water-withdrawal estimates for livestock that can be used by water managers and planners to determine water needs and trends across the United States. Water withdrawals for livestock in 2005 were estimated by using water-use coefficients, in gallons per head per day for each animal type, and livestock-population data. Coefficients for various livestock for most States were obtained from U.S. Geological Survey water-use program personnel or U.S. Geological Survey water-use publications. When no coefficient was available for an animal type in a State, the median value of reported coefficients for that animal was used. Livestock-population data were provided by the National Agricultural Statistics Service. County estimates were further divided into ground-water and surface-water withdrawals for each county and county equivalent. County totals from 2005 were compared to county totals from 1995 and 2000. Large deviations from 1995 or 2000 livestock withdrawal estimates were investigated and generally were due to comparison with reported withdrawals, differences in estimation techniques, differences in livestock

  6. The importance of lake-specific characteristics for water quality across the continental United States.

    Read, Emily K; Patil, Vijay P; Oliver, Samantha K; Hetherington, Amy L; Brentrup, Jennifer A; Zwart, Jacob A; Winters, Kirsten M; Corman, Jessica R; Nodine, Emily R; Woolway, R Iestyn; Dugan, Hilary A; Jaimes, Aline; Santoso, Arianto B; Hong, Grace S; Winslow, Luke A; Hanson, Paul C; Weathers, Kathleen C

    2015-06-01

    Lake water quality is affected by local and regional drivers, including lake physical characteristics, hydrology, landscape position, land cover, land use, geology, and climate. Here, we demonstrate the utility of hypothesis testing within the landscape limnology framework using a random forest algorithm on a national-scale, spatially explicit data set, the United States Environmental Protection Agency's 2007 National Lakes Assessment. For 1026 lakes, we tested the relative importance of water quality drivers across spatial scales, the importance of hydrologic connectivity in mediating water quality drivers, and how the importance of both spatial scale and connectivity differ across response variables for five important in-lake water quality metrics (total phosphorus, total nitrogen, dissolved organic carbon, turbidity, and conductivity). By modeling the effect of water quality predictors at different spatial scales, we found that lake-specific characteristics (e.g., depth, sediment area-to-volume ratio) were important for explaining water quality (54-60% variance explained), and that regionalization schemes were much less effective than lake specific metrics (28-39% variance explained). Basin-scale land use and land cover explained between 45-62% of variance, and forest cover and agricultural land uses were among the most important basin-scale predictors. Water quality drivers did not operate independently; in some cases, hydrologic connectivity (the presence of upstream surface water features) mediated the effect of regional-scale drivers. For example, for water quality in lakes with upstream lakes, regional classification schemes were much less effective predictors than lake-specific variables, in contrast to lakes with no upstream lakes or with no surface inflows. At the scale of the continental United States, conductivity was explained by drivers operating at larger spatial scales than for other water quality responses. The current regulatory practice of using

  7. Occurrence and in vitro bioactivity of estrogen, androgen, and glucocorticoid compounds in a nationwide screen of United States stream waters

    U.S. Environmental Protection Agency — In vitro bioactivity concentrations and chemical concentrations of estrogens, androgens, and glucocorticoids from a nationwide screen of United States stream water...

  8. Energy Savings and Breakeven Cost for Residential Heat Pump Water Heaters in the United States

    Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

    2013-07-01

    Heat pump water heaters (HPWHs) have recently reemerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, simulations were performed of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern US. When replacing an electric water heater, the HPWH is likely to break even in California, the southern US, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  9. Microfouling assessment and its control in a heavy water production unit

    Rajesh Kumar; Subba Rao, T.

    2015-01-01

    The water treatment plant (WTP) of a heavy water production unit was extensively fouled by microorganisms. On-site investigations showed severe algal and bacterial growth in the various units of WTP and very dense microbial fouling in the vacuum degasser (VD) unit. Digital and microscopic images showed that the microfouling problem was primarily due to a slime bacterium and a fungus. Microbiological analysis showed a bacterial count of ∼10 5 cfu ml -1 in the various sections of WTP. The slime/biofilm scrapings had very high bacterial population (>10 9 cfu cm -2 ). High organic carbon values in the system (5.0 to 19.5 ppm) had supported microbial growth in WTP and augmented resin fouling. Chlorination was inadequate in controlling microfouling, consequently chlorine dioxide was tested and found to be a better biocide. A 2.0% sodium omadine solution had completely inhibited the fouling fungus. (author)

  10. Water-Chemistry and Its Utility Systems in CCP Power Units (Review)

    Larin, B. M.

    2018-01-01

    Damageability of heat transfer surfaces of waste heat recovery steam generators (HRSG) of combined- cycle plants (CCP) can be reduced due to an increase in the quality of make-up and feed water, the use of phosphate-alkaline or amino compound water chemistry (WC), and improved chemical quality control of the heat carrier and make-up water preparation techniques. Temporary quality standards for the heat medium developed by the All-Russia Thermal Engineering institute (VTI) for CCP power units are presented in comparison with the IAPWS standards; preferences for the choice of a WC type for some power units commissioned in Russia in the first decade of this century are shown; and operational data on the quality of feed, boiler water, and steam for two large CCP-450 and CCP-425 power units are given. The state and prospects for the development of chemical-technological monitoring systems and CCP water treatment plants are noted. Estimability of some CCP diagnostic parameters by measuring specific electric conductivity and pH is shown. An extensive bibliography on this topic is given.

  11. Withdrawal and consumption of water by thermoelectric power plants in the United States, 2010

    Diehl, Timothy H.; Harris, Melissa A.

    2014-01-01

    Estimates of water use at thermoelectric plants were developed by the U.S. Geological Survey based on linked heat and water budgets, and complement reported thermoelectric water withdrawals and consumption. The heat- and water-budget models produced withdrawal and consumption estimates, including thermodynamically plausible ranges of minimum and maximum withdrawal and consumption, for 1,290 water-using plants in the United States for 2010. Total estimated withdrawal for 2010 was about 129 billion gallons per day (Bgal/d), and total estimated consumption was about 3.5 Bgal/d. In contrast, total withdrawal reported by the U.S. Department of Energy, Energy Information Administration (EIA), was about 24 percent higher than the modeled estimates, and total EIA-reported consumption was about 8 percent lower. Most thermoelectric generation in 2010 was not associated with thermodynamically plausible EIA-reported values of both withdrawal and consumption.

  12. NOAA Water Level Predictions Stations for the Coastal United States and Other Non-U.S. Sites

    National Oceanic and Atmospheric Administration, Department of Commerce — The National Ocean Service (NOS) maintains a long-term database containing water level measurements and derived tidal data for coastal waters of the United States...

  13. Concentration of Selected Anions in Bottled Water in the United Arab Emirates

    Mohamed Yehia Z. Abouleish

    2012-05-01

    Full Text Available Several studies have shown concern over nitrate and nitrite contamination of prepared infant formula used by infants less than six months old, as it may lead to methemoglobinemia and death. One possible source of contamination is through the use of improperly treated drinking water. Contamination of water could result from fertilizers and manure runoff, not fully treated and released human and industrial waste, or from disinfection processes. In the United Arab Emirates (UAE, bottled water is the major source of drinking water and may be used for the preparation of infant formula. Therefore, in this study, several bottled water brands that are sold on the UAE market, and could be used for preparation of infant formula, were tested for nitrate and nitrite and other anions to show their compatibility with the permissible levels of the United States Environmental Protection Agency (U.S. EPA, United States Food and Drug Administration/Code of Federal Regulations (U.S. FDA/CFR, and other international organizations. All the bottled water samples demonstrated nitrate, nitrite, and other anions levels below the permissible levels accepted by U.S. EPA, U.S. FDA/CFR, and other international organizations, except for one sample that showed nitrite levels exceeding the European Commission and Drinking Water Directive (EC/DWD permissible levels. Such study sheds light on the quality of bottled water sold not only in the UAE and the region, but also in other countries, such as France, since some of them are imported. In addition, the results shed light on the effectiveness of the treatment processes and possible sources of infant formula contamination that can affect the health of infants.

  14. Low Temperature District Heating Consumer Unit with Micro Heat Pump for Domestic Hot Water Preparation

    Zvingilaite, Erika; Ommen, Torben Schmidt; Elmegaard, Brian

    2012-01-01

    In this paper we present and analyse the feasibility of a district heating (DH) consumer unit with micro heat pump for domestic hot water (DHW) preparation in a low temperature (40 °C) DH network. We propose a micro booster heat pump of high efficiency (COP equal to 5,3) in a consumer DH unit...... in order to boost the temperature of the district heating water for heating the DHW. The paper presents the main designs of the suggested system and different alternative micro booster heat pump concepts. Energy efficiency and thermodynamic performance of these concepts are calculated and compared....... The results show that the proposed system has the highest efficiency. Furthermore, we compare thermodynamic and economic performance of the suggested heat pump-based concept with different solutions, using electric water heater. The micro booster heat pump system has the highest annualised investment (390 EUR...

  15. Reducing water freshwater consumption at coal-fired power plants : approaches used outside the United States.

    Elcock, D. (Environmental Science Division)

    2011-05-09

    Coal-fired power plants consume huge quantities of water, and in some water-stressed areas, power plants compete with other users for limited supplies. Extensive use of coal to generate electricity is projected to continue for many years. Faced with increasing power demands and questionable future supplies, industries and governments are seeking ways to reduce freshwater consumption at coal-fired power plants. As the United States investigates various freshwater savings approaches (e.g., the use of alternative water sources), other countries are also researching and implementing approaches to address similar - and in many cases, more challenging - water supply and demand issues. Information about these non-U.S. approaches can be used to help direct near- and mid-term water-consumption research and development (R&D) activities in the United States. This report summarizes the research, development, and deployment (RD&D) status of several approaches used for reducing freshwater consumption by coal-fired power plants in other countries, many of which could be applied, or applied more aggressively, at coal-fired power plants in the United States. Information contained in this report is derived from literature and Internet searches, in some cases supplemented by communication with the researchers, authors, or equipment providers. Because there are few technical, peer-reviewed articles on this topic, much of the information in this report comes from the trade press and other non-peer-reviewed references. Reducing freshwater consumption at coal-fired power plants can occur directly or indirectly. Direct approaches are aimed specifically at reducing water consumption, and they include dry cooling, dry bottom ash handling, low-water-consuming emissions-control technologies, water metering and monitoring, reclaiming water from in-plant operations (e.g., recovery of cooling tower water for boiler makeup water, reclaiming water from flue gas desulfurization [FGD] systems), and

  16. Simulating the Water Use of Thermoelectric Power Plants in the United States: Model Development and Verification

    Betrie, G.; Yan, E.; Clark, C.

    2016-12-01

    Thermoelectric power plants use the highest amount of freshwater second to the agriculture sector. However, there is scarcity of information that characterizes the freshwater use of these plants in the United States. This could be attributed to the lack of model and data that are required to conduct analysis and gain insights. The competition for freshwater among sectors will increase in the future as the amount of freshwater gets limited due climate change and population growth. A model that makes use of less data is urgently needed to conduct analysis and identify adaptation strategies. The objectives of this study are to develop a model and simulate the water use of thermoelectric power plants in the United States. The developed model has heat-balance, climate, cooling system, and optimization modules. It computes the amount of heat rejected to the environment, estimates the quantity of heat exchanged through latent and sensible heat to the environment, and computes the amount of water required per unit generation of electricity. To verify the model, we simulated a total of 876 fossil-fired, nuclear and gas-turbine power plants with different cooling systems (CS) using 2010-2014 data obtained from Energy Information Administration. The CS includes once-through with cooling pond, once-through without cooling ponds, recirculating with induced draft and recirculating with induced draft natural draft. The results show that the model reproduced the observed water use per unit generation of electricity for the most of the power plants. It is also noticed that the model slightly overestimates the water use during the summer period when the input water temperatures are higher. We are investigating the possible reasons for the overestimation and address it in the future work. The model could be used individually or coupled to regional models to analyze various adaptation strategies and improve the water use efficiency of thermoelectric power plants.

  17. Assessing the adequacy of water storage infrastructure capacity under hydroclimatic variability and water demands in the United States

    Ho, M. W.; Devineni, N.; Cook, E. R.; Lall, U.

    2017-12-01

    As populations and associated economic activity in the US evolve, regional demands for water likewise change. For regions dependent on surface water, dams and reservoirs are critical to storing and managing releases of water and regulating the temporal and spatial availability of water in order to meet these demands. Storage capacities typically range from seasonal storage in the east to multi-annual and decadal-scale storage in the drier west. However, most dams in the US were designed with limited knowledge regarding the range, frequency, and persistence of hydroclimatic extremes. Demands for water supplied by these dams have likewise changed. Furthermore, many dams in the US are now reaching or have already exceeded their economic design life. The converging issues of aging dams, improved knowledge of hydroclimatic variability, and evolving demands for dam services result in a pressing need to evaluate existing reservoir capacities with respect to contemporary water demands, long term hydroclimatic variability, and service reliability into the future. Such an effort is possible given the recent development of two datasets that respectively address hydroclimatic variability in the conterminous United States over the past 555 years and human water demand related water stress over the same region. The first data set is a paleoclimate reconstruction of streamflow variability across the CONUS region based on a tree-ring informed reconstruction of the Palmer Drought Severity Index. This streamflow reconstruction suggested that wet spells with shorter drier spells were a key feature of 20th century streamflow compared with the preceding 450 years. The second data set in an annual cumulative drought index that is a measure of water balance based on water supplied through precipitation and water demands based on evaporative demands, agricultural, urban, and industrial demands. This index identified urban and regional hotspots that were particularly dependent on water

  18. Effect of Population Growths on Water Resources in Dubai Emirate, United Arab Emirates

    Al-Nuaimi, Hind S.; Murad, Ahmed A.

    The Emirate of Dubai is situated to the north of the United Arab Emirates on the Arabian Gulf. Due to its political stability and strong economy, people are continuing to immigrate to Dubai and this will enhance the stress on water resources. Therefore, demands for water will increase significantly in Dubai. The scarcity of water resources in Dubai is evident. The total production of water in the Dubai has increased to 61,478 million gallons in 2004. About 58,808 million gallons has been produced from the desalination plants in 2004. The production of freshwater from the main aquifers is about 2763 and 2655 million gallons for the years 2003 and 2004, respectively. The reduction of groundwater in 2004 may be ascribed to the low amount of rainfall and to the decreasing capacity of the aquifers. Treated wastewater is another source for water whose quantity was increased from 72 m3 to about 107 m3 in 2000 and 2004, respectively. The increase in water production in Dubai to meet the demand corresponds to population growth and this might be attributed to the political stability and strong economy. Moreover, major problems related to the water resources have appeared and affected the availability of freshwater in Dubai. These problems include: lowering water level and groundwater deterioration. This paper is aimed to assess the impacts of population growth on water resources in Dubai.

  19. Subpopulations in purified platelets adhering on glass.

    Donati, Alessia; Gupta, Swati; Reviakine, Ilya

    2016-06-22

    Understanding how platelet activation is regulated is important in the context of cardiovascular disorders and their management with antiplatelet therapy. Recent evidence points to different platelet subpopulations performing different functions. In particular, procoagulant and aggregating subpopulations have been reported in the literature in platelets treated with the GPVI agonists. How the formation of platelet subpopulations upon activation is regulated remains unclear. Here, it is shown that procoagulant and aggregating platelet subpopulations arise spontaneously upon adhesion of purified platelets on clean glass surfaces. Calcium ionophore treatment of the adhering platelets resulted in one platelet population expressing both the procoagulant and the adherent population markers phosphatidylserine and the activated form of GPIIb/IIIa, while all of the platelets expressed CD62P independently of the ionophore treatment. Therefore, all platelets have the capacity to express all three activation markers. It is concluded that platelet subpopulations observed in various studies reflect the dynamics of the platelet activation process.

  20. Apparatus and methods for purifying lead

    Tunison, Harmon M.

    2016-01-12

    Disclosed is an exemplary method of purifying lead which includes the steps of placing lead and a fluoride salt blend in a container; forming a first fluid of molten lead at a first temperature; forming a second fluid of the molten fluoride salt blend at a second temperature higher than the first temperature; mixing the first fluid and the second fluid together; separating the two fluids; solidifying the molten fluoride salt blend at a temperature above a melting point of the lead; and removing the molten lead from the container. In certain exemplary methods the molten lead is removed from the container by decanting. In still other exemplary methods the molten salt blend is a Lewis base fluoride eutectic salt blend, and in yet other exemplary methods the molten salt blend contains sodium fluoride, lithium fluoride, and potassium fluoride.

  1. The Role of Overshooting Convection in Elevated Stratospheric Water Vapor over the Summertime Continental United States

    Herman, R. L.; Ray, E. A.; Rosenlof, K. H.; Bedka, K. M.; Schwartz, M. J.; Read, W. G.; Troy, R. F.

    2016-12-01

    The NASA ER-2 aircraft sampled the UTLS region over North America during the NASA Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS) field mission. On four flights targeting convectively-influenced air parcels, in situ measurements of enhanced water vapor in the lower stratosphere over the summertime continental United States were made using the JPL Laser Hygrometer (JLH Mark2). Water vapor mixing ratios greater than 10 ppmv, twice the stratospheric background levels, were measured at pressure levels between 80 and 160 hPa. Through satellite observations and analysis, we make the connection between these in situ water measurements and overshooting cloud tops. The overshooting tops (OT) are identified from a SEAC4RS OT detection product based on satellite infrared window channel brightness temperature gradients. Back-trajectory analysis ties enhanced water to OT one to seven days prior to the intercept by the aircraft. The trajectory paths are dominated by the North American Monsoon (NAM) anticyclonic circulation. This connection suggests that ice is convectively transported to the overworld stratosphere in OT events and subsequently sublimated; such events may irreversibly enhance stratospheric water vapor in the summer over Mexico and the United States. Regional context is provided by water observations from the Aura Microwave Limb Sounder (MLS).

  2. Enhanced stratospheric water vapor over the summertime continental United States and the role of overshooting convection

    Herman, Robert L.; Ray, Eric A.; Rosenlof, Karen H.; Bedka, Kristopher M.; Schwartz, Michael J.; Read, William G.; Troy, Robert F.; Chin, Keith; Christensen, Lance E.; Fu, Dejian; Stachnik, Robert A.; Bui, T. Paul; Dean-Day, Jonathan M.

    2017-05-01

    The NASA ER-2 aircraft sampled the lower stratosphere over North America during the field mission for the NASA Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS). This study reports observations of convectively influenced air parcels with enhanced water vapor in the overworld stratosphere over the summertime continental United States and investigates three case studies in detail. Water vapor mixing ratios greater than 10 ppmv, which is much higher than the background 4 to 6 ppmv of the overworld stratosphere, were measured by the JPL Laser Hygrometer (JLH Mark2) at altitudes between 16.0 and 17.5 km (potential temperatures of approximately 380 to 410 K). Overshooting cloud tops (OTs) are identified from a SEAC4RS OT detection product based on satellite infrared window channel brightness temperature gradients. Through trajectory analysis, we make the connection between these in situ water measurements and OT. Back trajectory analysis ties enhanced water to OT 1 to 7 days prior to the intercept by the aircraft. The trajectory paths are dominated by the North American monsoon (NAM) anticyclonic circulation. This connection suggests that ice is convectively transported to the overworld stratosphere in OT events and subsequently sublimated; such events may irreversibly enhance stratospheric water vapor in the summer over Mexico and the United States. A regional context is provided by water observations from the Aura Microwave Limb Sounder (MLS).

  3. Estimating Water Footprints of Vegetable Crops: Influence of Growing Season, Solar Radiation Data and Functional Unit

    Betsie le Roux

    2016-10-01

    Full Text Available Water footprint (WF accounting as proposed by the Water Footprint Network (WFN can potentially provide important information for water resource management, especially in water scarce countries relying on irrigation to help meet their food requirements. However, calculating accurate WFs of short-season vegetable crops such as carrots, cabbage, beetroot, broccoli and lettuce presented some challenges. Planting dates and inter-annual weather conditions impact WF results. Joining weather datasets of just rainfall, minimum and maximum temperature with ones that include solar radiation and wind-speed affected crop model estimates and WF results. The functional unit selected can also have a major impact on results. For example, WFs according to the WFN approach do not account for crop residues used for other purposes, like composting and animal feed. Using yields in dry matter rather than fresh mass also impacts WF metrics, making comparisons difficult. To overcome this, using the nutritional value of crops as a functional unit can connect water use more directly to potential benefits derived from different crops and allow more straightforward comparisons. Grey WFs based on nitrogen only disregards water pollution caused by phosphates, pesticides and salinization. Poor understanding of the fate of nitrogen complicates estimation of nitrogen loads into the aquifer.

  4. Influence of Water and Mineral Oil on the Leaks in Satellite Motor Commutation Unit Clearances

    Śliwiński Paweł

    2017-09-01

    Full Text Available The article describes the flow rates of mineral oil and water flowing, as working media, through the commutation unit of a hydraulic satellite motor. It is demonstrated that geometrical dimensions of commutation unit clearances change as a function of the machine shaft rotation angle. Methods for measuring the rate of this flow and the pressure in the working chamber are presented. The results of pressure measurements in the working chamber during the transition from the filling cycle to the emptying cycle are included. The pressure in the motor’s working chamber changes linearly as a function of the shaft rotation angle, which has a significant effect on the leakage in the commutation unit clearances. The paper presents new mathematical formulas in the form: Q=f(Δpγ to calculate the flow rate of water and mineral oil in the commutation unit clearances. The γ factor is described as a function of fluid viscosity and clearance length (the motor shaft rotation angle. The coefficients used in these formulas were determined based on the results of laboratory tests of a motor supplied with water and mineral oil.

  5. Primary water chemistry control at units of Paks Nuclear Power Plant

    Schunk, J.; Patek, G.; Pinter, T.; Tilky, P.; Doma, A.; Osz, J.

    2010-01-01

    The primary water chemistry of the four identical units of Paks Nuclear Power Plant has been developed based on Western-type PWR units, taking into consideration some Soviet-Russian modifications. The political changes in 90s have also influenced the water chemistry specifications and directions. At PWR units the transition operational modes have been developed while in case of VVER units - in lack of central uniform regulation - this question has become the competence and responsibility of each individual plant. This problem has resulted in separate water chemistry developments with a considerable time delay. The needs for life-time extensions all over the World have made the development of start-up and shut-down chemistry procedures extremely important, since they considerably influence the long term and safe operation of plants. The uniformly structured limit value system, the principles applied for the system development, and the logic schemes for actions to be taken are discussed in the paper, both for normal operation and transition modes. (author)

  6. Methods for Estimating Water Withdrawals for Mining in the United States, 2005

    Lovelace, John K.

    2009-01-01

    The mining water-use category includes groundwater and surface water that is withdrawn and used for nonfuels and fuels mining. Nonfuels mining includes the extraction of ores, stone, sand, and gravel. Fuels mining includes the extraction of coal, petroleum, and natural gas. Water is used for mineral extraction, quarrying, milling, and other operations directly associated with mining activities. For petroleum and natural gas extraction, water often is injected for secondary oil or gas recovery. Estimates of water withdrawals for mining are needed for water planning and management. This report documents methods used to estimate withdrawals of fresh and saline groundwater and surface water for mining during 2005 for each county and county equivalent in the United States, Puerto Rico, and the U.S. Virgin Islands. Fresh and saline groundwater and surface-water withdrawals during 2005 for nonfuels- and coal-mining operations in each county or county equivalent in the United States, Puerto Rico, and the U.S. Virgin Islands were estimated. Fresh and saline groundwater withdrawals for oil and gas operations in counties of six states also were estimated. Water withdrawals for nonfuels and coal mining were estimated by using mine-production data and water-use coefficients. Production data for nonfuels mining included the mine location and weight (in metric tons) of crude ore, rock, or mineral produced at each mine in the United States, Puerto Rico, and the U.S. Virgin Islands during 2004. Production data for coal mining included the weight, in metric tons, of coal produced in each county or county equivalent during 2004. Water-use coefficients for mined commodities were compiled from various sources including published reports and written communications from U.S. Geological Survey National Water-use Information Program (NWUIP) personnel in several states. Water withdrawals for oil and gas extraction were estimated for six States including California, Colorado, Louisiana, New

  7. Determinação simultânea de As, Cd e Pb em amostras de água purificada para hemodiálise por espectrometria de absorção atômica com forno de grafite, após otimização multivariada baseada no uso de planejamento experimental Simultaneous determination of arsenic, cadmium and lead by GF AAS in purified water samples for hemodialysis after multivariate optimization based on factorial design

    Lisia Maria G. dos Santos

    2008-01-01

    Full Text Available This paper reports the development of a methodology for simultaneously determining As, Cd and Pb, employing GF AAS with polarized Zeeman-effect background correction. In order to make the procedure applicable, the influence of pyrolysis and atomization temperatures and the amount of chemical modifiers were studied. Factorial and central composite designs were used to optimize these variables. Precision and accuracy of the method were investigated using Natural Water Reference material, Nist SRM 1640. Results are in agreement with certified values at the 95% confidence limit when the Student t-test is used. This methodology was used for quality control of purified water for hemodialysis.

  8. Fabrication of Simple Indoor Air Haze Purifier using Domestic Discarded Substances and Its Haze Removal Performance

    Wang, Zhou; Cao, Haoshu; Zhao, Shuang

    2018-01-01

    Based on the concept of circular economy, discarded plastic bottles stuffed with discarded cotton, clothing and sofa cushion were used as pre-filter to remove big particles (dust and coal dust) in air and 4 L tap water in discarded plastic bottle was worked as an absorbing medium to dissolve the water soluble ions in air (SO4 2-, NO3-, NH4+, Cl- and Ca2+). Moreover, the internet control design was used in this homemade indoor air haze purifier to achieve the performance of remote control and intelligent management. The experimental results showed that this indoor air haze purifier can effectively reduce the level of indoor air haze and the air quality after 20 minutes treatment is higher than that of two commercial well-known air haze purifier

  9. Quality of Source Water from Public-Supply Wells in the United States, 1993-2007

    Toccalino, Patricia L.; Norman, Julia E.; Hitt, Kerie J.

    2010-01-01

    More than one-third of the Nation's population receives their drinking water from public water systems that use groundwater as their source. The U.S. Geological Survey (USGS) sampled untreated source water from 932 public-supply wells, hereafter referred to as public wells, as part of multiple groundwater assessments conducted across the Nation during 1993-2007. The objectives of this study were to evaluate (1) contaminant occurrence in source water from public wells and the potential significance of contaminant concentrations to human health, (2) national and regional distributions of groundwater quality, and (3) the occurrence and characteristics of contaminant mixtures. Treated finished water was not sampled. The 932 public wells are widely distributed nationally and include wells in selected parts of 41 states and withdraw water from parts of 30 regionally extensive aquifers used for public water supply. These wells are distributed among 629 unique public water systems-less than 1 percent of all groundwater-supplied public water systems in the United States-but the wells were randomly selected within the sampled hydrogeologic settings to represent typical aquifer conditions. Samples from the 629 systems represent source water used by one-quarter of the U.S. population served by groundwater-supplied public water systems, or about 9 percent of the entire U.S. population in 2008. One groundwater sample was collected prior to treatment or blending from each of the 932 public wells and analyzed for as many as six water-quality properties and 215 contaminants. Consistent with the terminology used in the Safe Drinking Water Act (SDWA), all constituents analyzed in water samples in this study are referred to as 'contaminants'. More contaminant groups were assessed in this study than in any previous national study of public wells and included major ions, nutrients, radionuclides, trace elements, pesticide compounds, volatile organic compounds (VOCs), and fecal

  10. 77 FR 40606 - United Water; Notice of Declaration of Intention and Petition for Relief, and Soliciting Comments...

    2012-07-10

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. DI12-8-000] United Water...: DI12-8-000. c. Date Filed: June 11, 2012. d. Applicant: United Water. e. Name of Project: Arlington... Contact: Jeffrey McDonald, PE, Project Director, Fuss & O'Neill, 146 Hartford Road, Manchester, CT 06040...

  11. Estimation of fluoride concentration in drinking water and common beverages in United Arab Emirates (UAE).

    Walia, Tarun; Abu Fanas, Salem; Akbar, Madiha; Eddin, Jamal; Adnan, Mohamad

    2017-07-01

    To assess fluoride concentration in drinking water which include tap water of 4 emirates - Abu Dhabi, Dubai, Sharjah and Ajman plus bottled water, commonly available soft drinks & juices in United Arab Emirates. Five different samples of tap water collected from each of the four emirates of UAE: Ajman, Sharjah, Abu Dhabi and Dubai; twenty-two brands of bottled water and fifteen brands of popular cold beverages, purchased from different supermarkets in U.A.E were tested using ion selective electrode method and the fluoride concentration was determined. The mean fluoride content of tap water samples was 0.14 mg F/L with a range of 0.04-0.3 mg F/L; with Ajman tap water samples showing the highest mean fluoride content of 0.3 mg F/L. The mean fluoride content for both bottled drinking water and beverages was 0.07 mg F/L with a range of 0.02-0.50 mg F/L and 0.04-0.1 mg F/L respectively. Majority (68.2%) of the bottled water are produced locally within U.A.E while a few (31.8%) are imported. The tap water, bottled water and beverages available in U.A.E show varying concentrations of fluoride, however none showed the optimal level necessary to prevent dental caries. Dental professionals in U.A.E should be aware of the fluoride concentrations before prescribing fluoride supplements to children.

  12. Water availability and vulnerability of 225 large cities in the United States

    Padowski, Julie C.; Jawitz, James W.

    2012-12-01

    This study presents a quantitative national assessment of urban water availability and vulnerability for 225 U.S. cities with population greater than 100,000. Here, the urban assessments account for not only renewable water flows, but also the extracted, imported, and stored water that urban systems access through constructed infrastructure. These sources represent important hydraulic components of the urban water supply, yet are typically excluded from water scarcity assessments. Results from this hydraulic-based assessment were compared to those obtained using a more conventional method that estimates scarcity solely based on local renewable flows. The inclusion of hydraulic components increased the mean availability to cities, leading to a significantly lower portion of the total U.S. population considered "at risk" for water scarcity (17%) than that obtained from the runoff method (47%). Water vulnerability was determined based on low-flow conditions, and smaller differences were found for this metric between at-risk populations using the runoff (66%) and hydraulic-based (54%) methods. The large increase in the susceptible population between the scarcity measures evaluated using the hydraulic method may better reconcile the seeming contradiction in the United States between perceptions of natural water abundance and widespread water scarcity. Additionally, urban vulnerability measures developed here were validated using a media text analysis. Vulnerability assessments that included hydraulic components were found to correlate with the frequency of urban water scarcity reports in the popular press while runoff-based measures showed no significant correlation, suggesting that hydraulic-based assessments provide better context for understanding the nature and severity of urban water scarcity issues.

  13. Diagnosis of small capacity reverse osmosis desalination unit for domestic water

    Hillali, Z.; Hamed, A.; Elfil, Hamza; Ferjani, E.

    2009-01-01

    Tunisian norm of drinking water tolerates a maximum TDS of 1.5 g/L, and the domestic water presents usually a salinity grater than 500 mg/L. In the last years, several small capacity reverse osmosis desalination prototypes have been marketed. They are used to desalinate brackish water with TDS lower than 1.5 g/L. This RO unit, tested with tap waters during four years, was diagnosed. The RO unit produces 10-15 L/Hour with a recovery rate between 25 and 40 pour cent and salt rejection in order of 90 pour cent. The salinity of the tested domestic water is located between 0.4 and 1.4 g/L. Water pretreatment is composed of three filtration operations (cartridge filter, granulate active carbon filter and 5 =m cartridge filter). Pretreated water is pumped through RO membrane with maximum pressure of 6 bars. At the 4th year, the RO unit performances were substantial decreased. Recovery rate and salt rejection fall down more than 50 and 100% respectively and the pressure drop increase from 1 to 2.1 bar The membrane regeneration allowed only the rate recovery restoration. The membrane selectivity was not improved. The membrane seems irreversibly damaged by the tap water chlorine none retained by the deficient pretreatment. An autopsy of the used RO membrane was done by different analysis techniques as SEM/EDX, AFM, XRD and FTIR spectroscopy. The analysis of membrane (proper and used) surfaces show a deposit film on the used membrane witch evaluated to environ 2 =m, it indicates a fooling phenomenon. The SEM photos show deterioration on the active layer material of the membrane witch seems attacked by the tap water chlorine. The X Rays Diffraction and FTIR show that the deposit collected on the used membrane contains organic and mineral (Gypsum, SiO 2 and clays) materials. Silicates and clays can exist in tap waters and reach the RO membrane when the pretreatment micro-filter became deficient. The Gypsum presence is due only to germination on the membrane.

  14. Purification by ion exchange resins of the heavy water of the reactors EL 1 and EL 2. A - the purifying process. Equipment and results; Purification par resines echangeuses d'ions de l'eau lourde des reacteurs EL1 et EL2. A - conduite de la purification. Installations et resultats

    Chenouard, J.; Roth, E. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The heavy water was purified by tapping off part of the moderator over a mixed bed of anion and cation exchangers. The heavy water leaving the columns has a resistivity reaching several-meg-ohms, which allows the resistivity of the moderator to be maintained between 10{sup 5} and 10{sup 6} ohms/cm. Two methods of deuteration of the ion exchangers are described, as well as the heavy water recuperation from resins charged with radioactive products. The influence of the purity of the water on the radiolytic dissociation is investigated. An interpretation of the variations in pH and of the formation of hydrogen peroxide is given. In addition the report contains a general description of the EL1 and EL2 purification installations. (author) [French] L'epuration de l'eau lourde a ete effectuee en derivant une partie du moderateur sur un lit melange d'echangeurs d'anions et de cations. Les colonnes delivrent de l'eau lourde dont la resistivite atteint plusieurs megohms; ceci permet d'entretenir la resistivite du moderateur entre 10{sup 5} et 10{sup 6} ohms/cm. Deux procedes deuteriation des echangeurs d'ions sont decrits de meme que la recuperation de l'eau lourde partir des resines chargees de produits radioactifs. L'influence de la purete de l'eau sur sa dissociation radiolytique est etudiee. Une interpretation est donnee des variations de pH et de la formation d'eau oxygenee. Le rapport comprend en outre une description generale des installations d'epuration de EL1et EL2. (auteur)

  15. Purification by ion exchange resins of the heavy water of the reactors EL 1 and EL 2. A - the purifying process. Equipment and results; Purification par resines echangeuses d'ions de l'eau lourde des reacteurs EL1 et EL2. A - conduite de la purification. Installations et resultats

    Chenouard, J; Roth, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The heavy water was purified by tapping off part of the moderator over a mixed bed of anion and cation exchangers. The heavy water leaving the columns has a resistivity reaching several-meg-ohms, which allows the resistivity of the moderator to be maintained between 10{sup 5} and 10{sup 6} ohms/cm. Two methods of deuteration of the ion exchangers are described, as well as the heavy water recuperation from resins charged with radioactive products. The influence of the purity of the water on the radiolytic dissociation is investigated. An interpretation of the variations in pH and of the formation of hydrogen peroxide is given. In addition the report contains a general description of the EL1 and EL2 purification installations. (author) [French] L'epuration de l'eau lourde a ete effectuee en derivant une partie du moderateur sur un lit melange d'echangeurs d'anions et de cations. Les colonnes delivrent de l'eau lourde dont la resistivite atteint plusieurs megohms; ceci permet d'entretenir la resistivite du moderateur entre 10{sup 5} et 10{sup 6} ohms/cm. Deux procedes deuteriation des echangeurs d'ions sont decrits de meme que la recuperation de l'eau lourde partir des resines chargees de produits radioactifs. L'influence de la purete de l'eau sur sa dissociation radiolytique est etudiee. Une interpretation est donnee des variations de pH et de la formation d'eau oxygenee. Le rapport comprend en outre une description generale des installations d'epuration de EL1et EL2. (auteur)

  16. Heterogeneous distribution of water in the mantle transition zone beneath United States inferred from seismic observations

    Wang, Y.; Pavlis, G. L.; Li, M.

    2017-12-01

    The amount of water in the Earth's deep mantle is critical for the evolution of the solid Earth and the atmosphere. Mineral physics studies have revealed that Wadsleyite and Ringwoodite in the mantle transition zone could store several times the volume of water in the ocean. However, the water content and its distribution in the transition zone remain enigmatic due to lack of direct observations. Here we use seismic data from the full deployment of the Earthscope Transportable Array to produce 3D image of P to S scattering of the mantle transition zone beneath the United States. We compute the image volume from 141,080 pairs of high quality receiver functions defined by the Earthscope Automated Receiver Survey, reprocessed by the generalized iterative deconvolution method and imaged by the plane wave migration method. We find that the transition zone is filled with previously unrecognized small-scale heterogeneities that produce pervasive, negative polarity P to S conversions. Seismic synthetic modeling using a point source simulation method suggests two possible structures for these objects: 1) a set of randomly distributed blobs of slight difference in size, and 2) near vertical diapir structures from small scale convections. Combining with geodynamic simulations, we interpret the observation as compositional heterogeneity from small-scale, low-velocity bodies that are water enriched. Our results indicate there is a heterogeneous distribution of water through the entire mantle transition zone beneath the contiguous United States.

  17. Biofilm problems in dental unit water systems and its practical control.

    Coleman, D C

    2009-05-01

    Dental chair units (DCUs) contain integrated systems that provide the instruments and services for a wide range of dental procedures. DCUs use water to cool and irrigate DCU-supplied instruments and tooth surfaces during dental treatment. Water is supplied to these instruments by a network of interconnected narrow-bore (2-3 mm) plastic tubes called dental unit waterlines (DUWLs). Many studies over the last 40 years demonstrated that DUWL output water is often contaminated with high densities of micro-organisms, predominantly Gram-negative aerobic heterotropic environmental bacteria, including Legionella and Pseudomonas species. Untreated DUWLs host biofilms that permit micro-organisms to multiply and disperse through the water network and which are aerosolized by DCU instrument use, thus exposing patients and staff to these micro-organisms, to fragments of biofilm and bacterial endotoxins. This review concentrates on how practical developments and innovations in specific areas can contribute to effective DUWL biofilm control. These include the use of effective DUWL treatment agents, improvements to DCU supply water quality, DCU design changes, development of automated DUWL treatment procedures that are effective at controlling biofilm in the long-term and require minimal human intervention, are safe for patients and staff, and which do not cause deterioration of DCU components following prolonged use.

  18. Reducing water consumption of an industrial plant cooling unit using hybrid cooling tower

    Rezaei, Ebrahim; Shafiei, Sirous; Abdollahnezhad, Aydin

    2010-01-01

    Water consumption is an important problem in dry zones and poor water supply areas. For these areas use of a combination of wet and dry cooling towers (hybrid cooling) has been suggested in order to reduce water consumption. In this work, wet and dry sections of a hybrid cooling tower for the estimation of water loss was modeled. A computer code was also written to simulate such hybrid cooling tower. To test the result of this simulation, a pilot hybrid tower containing a wet tower and 12 compact air cooled heat exchangers was designed and constructed. Pilot data were compared with simulation data and a correction factor was added to the simulation. Ensuring that the simulation represents the actual data, it was applied to a real industrial case and the effect of using a dry tower on water loss reduction of this plant cooling unit was investigated. Finally feasibility study was carried out to choose the best operating conditions for the hybrid cooling tower configuration proposed for this cooling unit.

  19. Summary of estimated water use in the United States in 2015

    Maupin, Molly A.

    2018-06-19

    A total of 322 Bgal/d of water withdrawals was reported for eight categories of use in the United States in 2015, which was 9 percent less than in 2010 (354 Bgal/d), and continued a declining trend since 2005. The decline in total withdrawals in 2015 primarily was caused by significant decreases (28.8 Bgal/d) in thermoelectric power, which accounted for 89 percent of the decrease in total withdrawals. Between 2010 and 2015, withdrawals decreased in all categories except irrigation (2 percent increase), mining (1 percent increase), and livestock (no change). Fresh surface-water withdrawals (198 Bgal/d) were 14 percent less than in 2010, and fresh groundwater withdrawals (82.3 Bgal/d) were about 8 percent more than in 2010. Saline surface-water withdrawals (38.6 Bgal/d) were 14 percent less than in 2010, and saline groundwater withdrawals (2.34 Bgal/d) were 5 percent more than in 2010. Total population in the United States in 2015 (325 million) increased by 4 percent (12.4 million) from 2010, which was similar to the increase between 2005 and 2010. For the first time since 1995, consumptive use for irrigation and thermoelectric power were reported. Consumptive use accounted for 62 percent (73.2 Bgal/d) of water used for irrigation, and 3 percent (4.31 Bgal/d) of water used for thermoelectric power in 2015.

  20. Chillers and cold water units. Special issue; Chillers en koudwateraggregaten. Thema

    Van Zwam, P. [GEA Refrigeration Components Benelux, Den Bosch (Netherlands); Meijer, W. [Daikin Airconditioning Netherlands, Rotterdam (Netherlands); Torsy, E. [Trane Airconditioning, Soest (Netherlands); Berends, E. [GEA Grenco Refrigeration, Den Bosch (Netherlands); Havenaar, D. (ed.)

    2010-05-15

    In five articles attention is paid to several aspects of chillers and cold water units: (1) reduction of refrigerants and increase of the COP; (2) realization of high partial load efficiency in mono-screw compressors; (3) energy efficient innovation for cooling and heat pump systems; (4) application of modern chiller technology for a skating rink of Sportboulevard, Dordrecht, Netherlands; and (5) the use of propane as a refrigerant in air-cooled cold water units. [Dutch] In vijf artikelen wordt aandacht besteed aan verschillende aspecten van chillers en koudwateraggregaten: (1) minimaliseren van koudemiddeleninhoud en verhogen van de COP; (2) realisatie van hoge deellastrendementen met mono-schroefcompressoren; (3) energie efficiente innovaties voor koelmachine- en warmtepompsystemen; (4) toepassing van moderne chillertechnologie in de ijshal van Sportboulevard Dordrecht; en (5) het gebruik van propaan als koudemiddel in luchtgekoelde koudwateraggregaten.

  1. High Resolution Map of Water Supply and Demand for North East United States

    Ehsani, N.; Vorosmarty, C. J.; Fekete, B. M.

    2012-12-01

    Accurate estimates of water supply and demand are crucial elements in water resources management and modeling. As part of our NSF-funded EaSM effort to build a Northeast Regional Earth System Model (NE-RESM) as a framework to improve our understanding and capacity to forecast the implications of planning decisions on the region's environment, ecosystem services, energy and economic systems through the 21st century, we are producing a high resolution map (3' x 3' lat/long) of estimated water supply and use for the north east region of United States. Focusing on water demand, results from this study enables us to quantify how demand sources affect the hydrology and thermal-chemical water pollution across the region. In an attempt to generate this 3-minute resolution map in which each grid cell has a specific estimated monthly domestic, agriculture, thermoelectric and industrial water use. Estimated Use of Water in the United States in 2005 (Kenny et al., 2009) is being coupled to high resolution land cover and land use, irrigation, power plant and population data sets. In addition to water demands, we tried to improve estimates of water supply from the WBM model by improving the way it controls discharge from reservoirs. Reservoirs are key characteristics of the modern hydrologic system, with a particular impact on altering the natural stream flow, thermal characteristics, and biogeochemical fluxes of rivers. Depending on dam characteristics, watershed characteristics and the purpose of building a dam, each reservoir has a specific optimum operating rule. It means that literally 84,000 dams in the National Inventory of Dams potentially follow 84,000 different sets of rules for storing and releasing water which must somehow be accounted for in our modeling exercise. In reality, there is no comprehensive observational dataset depicting these operating rules. Thus, we will simulate these rules. Our perspective is not to find the optimum operating rule per se but to find

  2. Challenges with secondary use of multi-source water-quality data in the United States

    Sprague, Lori A.; Oelsner, Gretchen P.; Argue, Denise M.

    2017-01-01

    Combining water-quality data from multiple sources can help counterbalance diminishing resources for stream monitoring in the United States and lead to important regional and national insights that would not otherwise be possible. Individual monitoring organizations understand their own data very well, but issues can arise when their data are combined with data from other organizations that have used different methods for reporting the same common metadata elements. Such use of multi-source data is termed “secondary use”—the use of data beyond the original intent determined by the organization that collected the data. In this study, we surveyed more than 25 million nutrient records collected by 488 organizations in the United States since 1899 to identify major inconsistencies in metadata elements that limit the secondary use of multi-source data. Nearly 14.5 million of these records had missing or ambiguous information for one or more key metadata elements, including (in decreasing order of records affected) sample fraction, chemical form, parameter name, units of measurement, precise numerical value, and remark codes. As a result, metadata harmonization to make secondary use of these multi-source data will be time consuming, expensive, and inexact. Different data users may make different assumptions about the same ambiguous data, potentially resulting in different conclusions about important environmental issues. The value of these ambiguous data is estimated at \\$US12 billion, a substantial collective investment by water-resource organizations in the United States. By comparison, the value of unambiguous data is estimated at \\$US8.2 billion. The ambiguous data could be preserved for uses beyond the original intent by developing and implementing standardized metadata practices for future and legacy water-quality data throughout the United States.

  3. Microbial pathogens in source and treated waters from drinking water treatment plants in the United States and implications for human health

    An occurrence survey was conducted on selected pathogens in source and treated drinking water collected from 25 drinking water treatment plants (DWTPs) in the United States. Water samples were analyzed for the protozoa Giardia and Cryptosporidium (EPA Method 1623); the fungi Aspe...

  4. Closed-cycle process of coke-cooling water in delayed coking unit

    Zhou, P.; Bai, Z.S.; Yang, Q.; Ma, J.; Wang, H.L.

    2008-01-01

    Synthesized processes are commonly used to treat coke-cooling wastewater. These include cold coke-cut water, diluting coke-cooling water, adding chemical deodorization into oily water, high-speed centrifugal separation, de-oiling and deodorization by coke adsorption, and open nature cooling. However, because of water and volatile evaporation loss, it is not suitable to process high-sulphur heavy oil using open treatments. This paper proposed a closed-cycling process in order to solve the wastewater treatment problem. The process is based on the characteristics of coke-cooling water, such as rapid parametric variation, oil-water-coke emulsification and steam-water mixing. The paper discussed the material characteristics and general idea of the study. The process of closed-cycle separation and utilization process of coke-cooling water was presented along with a process flow diagram. Several applications were presented, including a picture of hydrocyclones for pollution separation and a picture of equipments of pollution separation and components regeneration. The results showed good effect had been achieved since the coke-cooling water system was put into production in 2004. The recycling ratios for the components of the coke-cooling water were 100 per cent, and air quality in the operating area reached the requirements of the national operating site circumstance and the health standards. Calibration results of the demonstration unit were presented. It was concluded that since the devices went into operation, the function of production has been normal and stable. The operation was simple, flexible, adjustable and reliable, with significant economic efficiency and environmental benefits. 10 refs., 2 tabs., 3 figs

  5. Statistical Analysis of Terrestrial Water Storage Change Over Southwestern United States

    Eibedingil, I. G.; Mubako, S. T.; Hargrove, W. L.; Espino, A. C.

    2017-12-01

    A warming trend over recent decades has aggravated water resource challenges in the arid southwestern region of the United States (U.S.). An increase in temperature, coupled with decreasing snowpack and rainfall have impacted the region's cities, ecosystems, and agriculture. The region is the largest contributor of agricultural products to the U.S. market resulting from irrigation. Water use through irrigation is stressing already limited terrestrial water resources. Population growth in recent decades has also led to increased water demand. This study utilizes products of the Gravity Recovery and Climate Experiment (GRACE) twin satellites experiment in MATLAB and ArcGIS to examine terrestrial water storage changes in the southwestern region of the U.S., comprised of the eight states of Texas, California, Nevada, Utah, Arizona, Colorado, New Mexico, and Oklahoma. Linear trend analysis was applied to the equivalent water-height data of terrestrial water storage changes (TWSC), precipitation, and air temperature. Correlation analysis was performed on couplings of TWSC - precipitation and TWSC - air temperature to examine the impact of temperature and precipitation on the region's water resources. Our preliminary results show a decreasing trend of TWSC from April 2002 to July 2016 in almost all parts of the region. Precipitation shows a decreasing trend from March 2000 to March 2017 for most of the region, except for sparse areas of increased precipitation near the northwestern coast of California, and a belt running from Oklahoma through the middle of Texas to the El Paso/New Mexico border. From April 2002 to December 2014, air temperature exhibited a negative trend for most of the region, except a larger part of California and a small location in central Texas. Correlation between TWSC and precipitation was mostly positive, but a negative trend was observed when TWSC and air temperature were correlated. The study contributes to the understanding of terrestrial water

  6. Surveillance for waterborne disease outbreaks associated with drinking water---United States, 2007--2008.

    Brunkard, Joan M; Ailes, Elizabeth; Roberts, Virginia A; Hill, Vincent; Hilborn, Elizabeth D; Craun, Gunther F; Rajasingham, Anu; Kahler, Amy; Garrison, Laurel; Hicks, Lauri; Carpenter, Joe; Wade, Timothy J; Beach, Michael J; Yoder Msw, Jonathan S

    2011-09-23

    Since 1971, CDC, the Environmental Protection Agency (EPA), and the Council of State and Territorial Epidemiologists have collaborated on the Waterborne Disease and Outbreak Surveillance System (WBDOSS) for collecting and reporting data related to occurrences and causes of waterborne disease outbreaks associated with drinking water. This surveillance system is the primary source of data concerning the scope and health effects of waterborne disease outbreaks in the United States. Data presented summarize 48 outbreaks that occurred during January 2007--December 2008 and 70 previously unreported outbreaks. WBDOSS includes data on outbreaks associated with drinking water, recreational water, water not intended for drinking (WNID) (excluding recreational water), and water use of unknown intent (WUI). Public health agencies in the states, U.S. territories, localities, and Freely Associated States are primarily responsible for detecting and investigating outbreaks and reporting them voluntarily to CDC by a standard form. Only data on outbreaks associated with drinking water, WNID (excluding recreational water), and WUI are summarized in this report. Outbreaks associated with recreational water are reported separately. A total of 24 states and Puerto Rico reported 48 outbreaks that occurred during 2007--2008. Of these 48 outbreaks, 36 were associated with drinking water, eight with WNID, and four with WUI. The 36 drinking water--associated outbreaks caused illness among at least 4,128 persons and were linked to three deaths. Etiologic agents were identified in 32 (88.9%) of the 36 drinking water--associated outbreaks; 21 (58.3%) outbreaks were associated with bacteria, five (13.9%) with viruses, three (8.3%) with parasites, one (2.8%) with a chemical, one (2.8%) with both bacteria and viruses, and one (2.8%) with both bacteria and parasites. Four outbreaks (11.1%) had unidentified etiologies. Of the 36 drinking water--associated outbreaks, 22 (61.1%) were outbreaks of

  7. Feasibility Analysis of Liquefying Oxygen Generated from Water Electrolysis Units on Lunar Surface

    Jeng, Frank F.

    2009-01-01

    Concepts for liquefying oxygen (O2) generated from water electrolysis subsystems on the Lunar surface were explored. Concepts for O2 liquefaction units capable of generating 1.38 lb/hr (0.63 kg/hr) liquid oxygen (LOX) were developed. Heat and mass balance calculations for the liquefaction concepts were conducted. Stream properties, duties of radiators, heat exchangers and compressors for the selected concepts were calculated and compared.

  8. Study of hot corrosion of flakes of non purified graphite and of purified graphite

    Boule, Michel

    1967-01-01

    The author reports the study of hot corrosion of the Ticonderoga graphite. He reports the study of the defects of graphite flakes (structure defects due to impurities), the dosing of these impurities, and then their removal by purification. Flakes have then been oxidised by means of a specially designed apparatus. Based on photographs taken by optical and electronic microscopy, the author compares the oxidation features obtained in dry air and in humid air, between purified and non purified flakes. He also reports the study of the evolution of oxidation with respect to the initial rate of impurities, and the study of the evolution of oxidation features in humid air during oxidation. All these comparisons are made while taking the oxidation rate into account [fr

  9. Determination of Absorbed Dose to Water for Leksell Gamma Knife Unit

    Hrsak, H.

    2013-01-01

    Because of geometry of photon beams in Leksell Gamma Knife Unit (LGK), there are several technical problems in applying standard protocols for determination of absorbed dose to water (Dw). Currently, Dw in LGK unit, measured at the center of spherical plastic phantom, is used for dose calculation in LGK radiosurgery. Treatment planning software (LGP TPS) accepts this value as a measurement in water and since plastic phantom has higher electron density than water, this leads to systematic errors in dose calculation. To reduce these errors, a photon attenuation correction (PAC) method was applied. For that purpose, measurements of absorbed dose in a center of three different plastic phantoms with 16 cm diameter (ABS - acrylonitrile butadiene styrene, PMMA - polymethyl metacrylate, PMMA + teflon - polytetrafluoroethylene 5 mm shell) were made with ionization chamber (Semiflex, PTW Freiburg). For measured dose values, PAC to water was applied based on electron density (ED) and equivalent water depths (EWD) of the plastic phantoms. The relation between CT number and ED was determined by measuring CT number of standard CT to ED phantom (CIRS Model 062 Phantom). Absorbed dose in plastic phantoms was 2.5 % lower than calculated dose in water for ABS phantom and more than 5.5 % lower for PMMA and PMMA+teflon phantom. Calculated dose in water showed more consistent values for all three phantoms (max. difference 2.6 %). EWD for human cranial bones and brain has value close to the EWD of ABS phantom, which makes this phantom most suitable for dose measurements in clinical application. In LGK radiosurgery determination of errors related to the difference of phantom materials should not be neglected and measured dose should be corrected before usage for patient treatment dose calculation.(author)

  10. Review of the desalinated water market in France for small units

    Dutheil, F.; Malissen, M.

    1969-01-01

    On the initiative of and in close collaboration with the Commissariat a l'Energie Atomique, the Societe pour la Conversion et le Developpement Industriel (SODIC) has carried out a very general study of the coastal regions of France in which the short, medium and long-term prospects of the demand for water, and the cost of the necessary supplies, could possibly make desalination units of 3 000 to 10 000 m3/day competitive. So far this general enquiry, which went into detail on some particular aspects, has not revealed any very clear possibilities in this respect, except in the case of the small islands, and of units of much lower capacity, as well as that of large units on the coast, which would benefit from the size effect. However the probable difference between the cost of desalinated water and the high selling price already applying in a small number of coastal regions is relatively small. It might therefore be worthwhile and relatively inexpensive to install an experimental desalination unit in the near future. (author) [fr

  11. ICEMENERG technologies of water treatment applied at Cernavoda NPP Unit 1

    Stanca, Angela; Bolma, Aurelia; Serbanescu, Agnes; Raducanu, Alice

    2002-01-01

    The paper presents the ICEMENERG technologies for water treatment applied at Cernavoda Unit 1, the treatment of the additional water for power steam generators and the chemical treatment of cooling system water. The requirements for quality of water totally demineralized as imposed by the AECL-ANSALDO consortium are as following: electrical conductivity, < 0.2 mS/cm; total silicon, <0.02 mg/L; ionic silicon, <0.01 mg/L; sodium, < 0.05 mg/L; TOC, <0.300 mg/L. These requirements raise rather difficult problems to be solved because the raw water source in case of Cernavoda NPP is Danube River which presents a raising trend of organic and inorganic contamination. Accordingly, experiments at laboratory scale reproducing the entire technological flow were conducted. The following operations were studied: pretreatment with limewash, ferric chloride (with and without coagulation additives); demineralization with ion exchangers of Purolite and Amberlite types. The system consisted of a cationic stage, formed of an strongly acid step with countercurrent recovery and an anionic stage formed of two steps, namely, a weakly basic step and a strongly basic step with recovery inserted; finishing on mixed bed. The paper presents also the chemical treatment/conditioning of the cooling loop of turbine condenser. The Cernavoda NPP cooling system is an open system with a single flow of cooling water comprising two systems, namely, the circulation water system ensuring the steam condenser cooling and the servicing water system ensuring the cooling of heat exchangers in the recirculated water circuit (RCWS), the turbine oil coolants, the coolants of auxiliary steam as well as the emergency core cooling system. Studies were conducted to ensure the chemical conditioning of the raw water from Danube River, particularly, to destroy and remove the shells, the algae and other components. Finally, the following four steps of conditioning the water of the cooling system are summarized: 1

  12. Public supply and domestic water use in the United States, 2015

    Dieter, Cheryl A.; Maupin, Molly A.

    2017-10-30

    IntroductionThe U.S. Geological Survey (USGS) National Water Use Science Project (NWUSP), part of the USGS Water Availability and Use Science Program (WAUSP), has estimated water use in the United States every 5 years since 1950. This report provides an overview of total population, public-supply use, including the population that is served by public-supply systems and the domestic deliveries to those users, and self-supplied domestic water use in the United States for 2015, continuing the task of estimating water use in the United States every 5 years. In this report, estimates for the United States include the 50 States, the District of Columbia, Puerto Rico, and the U.S. Virgin Islands (hereafter referred to as “states” for brevity).County-level data for total population, public-supply withdrawals and the population served by public-supply systems, and domestic withdrawals for 2015 were published in a data release in an effort to provide data to the public in a timely manner. Data in the current version (1.0) of Dieter and others (2017) contains county-level total withdrawals from groundwater and surface-water sources (both fresh and saline) for public-water supply, the deliveries from those suppliers to domestic users, and the quantities of water from groundwater and surface-water sources for self-supplied domestic users, and total population. Methods used to estimate the various data elements for the public-supply and domestic use categories at the county level are described by Bradley (2017).This Open-File Report is an interim report summarizing the data published in Dieter and others (2017) at the state and national level. This report includes discussions on the total population, totals for public-supply withdrawals and population served, total domestic withdrawals, and provides comparisons of the 2015 estimates to 2010 estimates (Maupin and others, 2014). Total domestic water use, as described in this report, represents the summation of deliveries from

  13. Improved evaluation of the blue water footprint from hydropower in the United States

    Zhao, G.; Gao, H.

    2017-12-01

    As the world's largest source of renewable energy, hydropower contributes 16.6% of the electricity production in the world. Even though it produces no waste, hydropower exhausts a considerable amount of water mostly through evaporation from the extended surface areas of the manmade lakes. The water footprint of hydropower becomes even larger with rising temperatures. To assist with the precise management of both water resources and energy production in the Contiguous United States (CONUS), 82 major dams—all with a primary purpose of producing hydroelectric power—were evaluated in terms of their blue water footprints. These dams account for 21% of the entire hydropower generation in the CONUS. Reservoir evaporation is calculated using state-of-the-art reservoir surface area and evaporation rate information. Instead of using fixed surface areas for the reservoirs—a practice which is adopted by virtually all other studies (and generally leads to over-or-under estimations)—time-variant surface areas were generated from Landsat imageries archived on Google Earth Engine (GEE) platform. Additionally, evaporation rates were calculated using an equilibrium method that incorporates the heat storage effects of the reservoirs. Results show that water consumption from hydropower is large and non-negligible. Furthermore, the differences of the blue water footprints among the dams studied are also significant. The results of this study can benefit the evaluation of existing dams (e.g. recommendation for dam removal) and the planning of future hydroelectric dams.

  14. Modelling the potential role of forest thinning in maintaining water supplies under a changing climate across the conterminous United States

    Ge Sun; Peter V. Caldwell; Steven G. McNulty

    2015-01-01

    The goal of this study was to test the sensitivity of water yield to forest thinning and other forest management/disturbances and climate across the conterminous United States (CONUS). Leaf area index (LAI) was selected as a key parameter linking changes in forest ecosystem structure and functions. We used the Water Supply Stress Index model to examine water yield...

  15. Channel water balance and exchange with subsurface flow along a mountain headwater stream in Montana, United States

    R.A. Payn; M.N. Gooseff; B.L. McGlynn; K.E. Bencala; S.M. Wondzell

    2009-01-01

    Channel water balances of contiguous reaches along streams represent a poorly understood scale of stream-subsurface interaction. We measured reach water balances along a headwater stream in Montana, United States, during summer base flow recessions. Reach water balances were estimated from series of tracer tests in 13 consecutive reaches delineated evenly along a 2.6-...

  16. A national perspective on paleoclimate streamflow and water storage infrastructure in the conterminous United States

    Ho, Michelle; Lall, Upmanu; Sun, Xun; Cook, Edward

    2017-04-01

    Large-scale water storage infrastructure in the Conterminous United States (CONUS) provides a means of regulating the temporal variability in water supply with storage capacities ranging from seasonal storage in the wetter east to multi-annual and decadal-scale storage in the drier west. Regional differences in water availability across the CONUS provides opportunities for optimizing water dependent economic activities, such as food and energy production, through storage and transportation. However, the ability to sufficiently regulate water supplies into the future is compromised by inadequate monitoring of non-federally-owned dams that make up around 97% of all dams. Furthermore, many of these dams are reaching or have exceeded their economic design life. Understanding the role of dams in the current and future landscape of water requirements in the CONUS is needed to prioritize dam safety remediation or identify where redundant dams may be removed. A national water assessment and planning process is needed for addressing water requirements, accounting for regional differences in water supply and demand, and the role of dams in such a landscape. Most dams in the CONUS were designed without knowledge of devastating floods and prolonged droughts detected in multi-centennial paleoclimate records, consideration of projected climate change, nor consideration of optimal operation across large-scale regions. As a step towards informing water supply across the CONUS we present a paleoclimate reconstruction of annual streamflow across the CONUS over the past 555 years using a spatially and temporally complete paleoclimate record of summer drought across the CONUS targeting a set of US Geological Survey streamflow sites. The spatial and temporal structures of national streamflow variability are analyzed using hierarchical clustering, principal component analysis, and wavelet analyses. The reconstructions show signals of contemporary droughts such as the Dust Bowl (1930s

  17. Anthropogenic organic compounds in source water of select community water systems in the United States, 2002-10

    Valder, Joshua F.; Delzer, Gregory C.; Kingsbury, James A.; Hopple, Jessica A.; Price, Curtis V.; Bender, David A.

    2014-01-01

    Drinking water delivered by community water systems (CWSs) comes from one or both of two sources: surface water and groundwater. Source water is raw, untreated water used by CWSs and is usually treated before distribution to consumers. Beginning in 2002, the U.S. Geological Survey’s (USGS) National Water-Quality Assessment Program initiated Source Water-Quality Assessments (SWQAs) at select CWSs across the United States, primarily to characterize the occurrence of a large number of anthropogenic organic compounds that are predominantly unregulated by the U.S. Environmental Protection Agency. Source-water samples from CWSs were collected during 2002–10 from 20 surface-water sites (river intakes) and during 2002–09 from 448 groundwater sites (supply wells). River intakes were sampled approximately 16 times during a 1-year sampling period, and supply wells were sampled once. Samples were monitored for 265 anthropogenic organic compounds. An additional 3 herbicides and 16 herbicide degradates were monitored in samples collected from 8 river intakes and 118 supply wells in areas where these compounds likely have been used. Thirty-seven compounds have an established U.S. Environmental Protection Agency (EPA) Maximum Contaminant Level (MCL) for drinking water, 123 have USGS Health-Based Screening Levels (HBSLs), and 29 are included on the EPA Contaminant Candidate List 3. All compounds detected in source water were evaluated both with and without an assessment level and were grouped into 13 categories (hereafter termed as “use groups”) based on their primary use or source. The CWS sites were characterized in a national context using an extract of the EPA Safe Drinking Water Information System to develop spatially derived and system-specific ancillary data. Community water system information is contained in the EPA Public Supply Database, which includes 2,016 active river intakes and 112,099 active supply wells. Ancillary variables including population served

  18. Potential Impacts of Climate Change on Stream Water Temperatures Across the United States

    Ehsani, N.; Knouft, J.; Ficklin, D. L.

    2017-12-01

    Analyses of long-term observation data have revealed significant changes in several components of climate and the hydrological cycle over the contiguous United States during the twentieth and early twenty-first century. Mean surface air temperatures have significantly increased in most areas of the country. In addition, water temperatures are increasing in many watersheds across the United States. While there are numerous studies assessing the impact of climate change on air temperatures at regional and global scales, fewer studies have investigated the impacts of climate change on stream water temperatures. Projecting increases in water temperature are particularly important to the conservation of freshwater ecosystems. To achieve better insights into attributes regulating population and community dynamics of aquatic biota at large spatial and temporal scales, we need to establish relationships between environmental heterogeneity and critical biological processes of stream ecosystems at these scales. Increases in stream temperatures caused by the doubling of atmospheric carbon dioxide may result in a significant loss of fish habitat in the United States. Utilization of physically based hydrological-water temperature models is computationally demanding and can be onerous to many researchers who specialize in other disciplines. Using statistical techniques to analyze observational data from 1760 USGS stream temperature gages, our goal is to develop a simple yet accurate method to quantify the impacts of climate warming on stream water temperatures in a way that is practical for aquatic biologists, water and environmental management purposes, and conservation practitioners and policy-makers. Using an ensemble of five global climate models (GCMs), we estimate the potential impacts of climate change on stream temperatures within the contiguous United States based on recent trends. Stream temperatures are projected to increase across the US, but the magnitude of the

  19. Proposal for Dual Pressurized Light Water Reactor Unit Producing 2000 MWe

    Kang, Kyoung Min; Noh, Sang Woo; Suh, Kune Yull

    2009-01-01

    The Dual Unit Optimizer 2000 MWe (DUO2000) is put forward as a new design concept for large power nuclear plants to cope with economic and safety challenges facing the 21 st century green and sustainable energy industry. DUO2000 is home to two nuclear steam supply systems (NSSSs) of the Optimized Power Reactor 1000 MWe (OPR1000)-like pressurized water reactor (PWR) in single containment so as to double the capacity of the plant. The idea behind DUO may as well be extended to combining any number of NSSSs of PWRs or pressurized heavy water reactors (PHWRs), or even boiling water reactors (BWRs). Once proven in water reactors, the technology may even be expanded to gas cooled, liquid metal cooled, and molten salt cooled reactors. With its in-vessel retention external reactor vessel cooling (IVR-ERVC) as severe accident management strategy, DUO can not only put the single most querulous PWR safety issue to an end, but also pave the way to very promising large power capacity while dispensing with the huge redesigning cost for Generation III+ nuclear systems. Five prototypes are presented for the DUO2000, and their respective advantages and drawbacks are considered. The strengths include, but are not necessarily limited to, reducing the cost of construction by decreasing the number of containment buildings from two to one, minimizing the cost of NSSS and control systems by sharing between the dual units, and lessening the maintenance cost by uniting the NSSS, just to name the few. The latent threats are discussed as well

  20. AQUAPEAT 95. New methods for purifying the run-offs of peat production areas

    Selin, P.; Marja-aho, J.; Madekivi, O.

    1994-01-01

    The aim of Aqua Peat 95-project was to develop new methods for purifying the runoff coming from the peat production areas. The national water protection program for the year 1995 (Ympaeristoeministerioe 1988) as well as the level of the requirements and instructions from the authorities will obligate the peat producers to find new and practical methods for water purification. The chemical treatment reduced the load of peat production areas and the quality of treated water was almost equal to the runoffs coming from the natural bog area. The chemicals were the same as used in purifying drinking water. This purifying method is quite expensive and for this reason applicable only in special cases. The transpiration and evaporation and the soil filtering capacity of the forest area was also observed. The purifying capacity was very good, especially for the total nutrients and suspended solids. The changes of the ground water quality were insignificant but the level of the ground water in the field areas was higher than before. The long term changes of the vegetation and the trees could not be seen, yet. The most important water management practice is the detention of the discharge. The capacity of the sedimentation will increase by using the flow regulation in the sedimentation ponds and ditches. The changes in the water biology downstreams the Laeynioensuo peat production area were clearly seen near the main ditch. Because of the suspended solids the bottom sediment changed which lead to impacts to the bottom fauna. The colour of the runoffs as well as the changes in the sediment influenced on the macrophytes

  1. Hydraulic Fracturing for Oil and Gas: Impacts from the Hydraulic Fracturing Water Cycle on Drinking Water Resources in the United States (Final Report)

    This final report provides a review and synthesis of available scientific information concerning the relationship between hydraulic fracturing activities and drinking water resources in the United States. The report is organized around activities in the hydraulic...

  2. Causes of Outbreaks Associated with Drinking Water in the United States from 1971 to 2006

    Craun, Gunther F.; Brunkard, Joan M.; Yoder, Jonathan S.; Roberts, Virginia A.; Carpenter, Joe; Wade, Tim; Calderon, Rebecca L.; Roberts, Jacquelin M.; Beach, Michael J.; Roy, Sharon L.

    2010-01-01

    Summary: Since 1971, the CDC, EPA, and Council of State and Territorial Epidemiologists (CSTE) have maintained the collaborative national Waterborne Disease and Outbreak Surveillance System (WBDOSS) to document waterborne disease outbreaks (WBDOs) reported by local, state, and territorial health departments. WBDOs were recently reclassified to better characterize water system deficiencies and risk factors; data were analyzed for trends in outbreak occurrence, etiologies, and deficiencies during 1971 to 2006. A total of 833 WBDOs, 577,991 cases of illness, and 106 deaths were reported during 1971 to 2006. Trends of public health significance include (i) a decrease in the number of reported outbreaks over time and in the annual proportion of outbreaks reported in public water systems, (ii) an increase in the annual proportion of outbreaks reported in individual water systems and in the proportion of outbreaks associated with premise plumbing deficiencies in public water systems, (iii) no change in the annual proportion of outbreaks associated with distribution system deficiencies or the use of untreated and improperly treated groundwater in public water systems, and (iv) the increasing importance of Legionella since its inclusion in WBDOSS in 2001. Data from WBDOSS have helped inform public health and regulatory responses. Additional resources for waterborne disease surveillance and outbreak detection are essential to improve our ability to monitor, detect, and prevent waterborne disease in the United States. PMID:20610821

  3. Bioavailability of the Nano-Unit 14C-Agrochemicals Under Various Water Potential.

    Jung, S C; Kim, H G; Kuk, Y I; Ahn, H G; Senseman, S A; Lee, D J

    2015-08-01

    The study was conducted to investigate the effects of water potential on bioavailability of the nano-unit 14C-cafenstrole, 14C-pretilachlor, 14C-benfuresate, 14C-simetryn and 14C-oxyfluorfen applied with or without dimepiperate or daimuron under various water potential conditions. The highest bioavailable concentration in soil solution (BCSS) was found at 60% soil moisture, while the lowest occurred at 50% soil moisture for soil-applied alone or in combination. All water potential conditions differed significantly from each other with variations in total bioavailable amount in soil solution (TBSS) when either dimepiperate or daimuron were added to the soil, and changes were directly proportional to variations in water potential. Across all treatments, TBSS at 80% soil moisture was three to four times greater than that at 50% soil moisture when applied alone or in combination with dimepiperate or daimuron. Cafenstrole and simetryn had distribution coefficient (Kd) values <64 ml g-1 and a TBSS ranging from 10 to 44 ng g-1 soil, regardless of water potential conditions applied alone or in combination. Pretilachlor and benfuresate had Kd values <15 ml g-1 and a TBSS range of 38 to 255 ng g-1 soil when applied with or without dimepiperate or daimuron.

  4. Mortality from selected diseases that can be transmitted by water - United States, 2003-2009.

    Gargano, J W; Adam, E A; Collier, S A; Fullerton, K E; Feinman, S J; Beach, M J

    2017-06-01

    Diseases spread by water are caused by fecal-oral, contact, inhalation, or other routes, resulting in illnesses affecting multiple body systems. We selected 13 pathogens or syndromes implicated in waterborne disease outbreaks or other well-documented waterborne transmission (acute otitis externa, Campylobacter, Cryptosporidium, Escherichia coli (E. coli), free-living ameba, Giardia, Hepatitis A virus, Legionella (Legionnaires' disease), nontuberculous mycobacteria (NTM), Pseudomonas-related pneumonia or septicemia, Salmonella, Shigella, and Vibrio). We documented annual numbers of deaths in the United States associated with these infections using a combination of death certificate data, nationally representative hospital discharge data, and disease-specific surveillance systems (2003-2009). We documented 6,939 annual total deaths associated with the 13 infections; of these, 493 (7%) were caused by seven pathogens transmitted by the fecal-oral route. A total of 6,301 deaths (91%) were associated with infections from Pseudomonas, NTM, and Legionella, environmental pathogens that grow in water system biofilms. Biofilm-associated pathogens can cause illness following inhalation of aerosols or contact with contaminated water. These findings suggest that most mortality from these 13 selected infections in the United States does not result from classical fecal-oral transmission but rather from other transmission routes.

  5. Control of water infiltration into near surface LLW disposal units: Task report, A discussion

    Schulz, R.K.; Ridky, R.W.; O'Donnell, E.

    1988-03-01

    The principal pathway for water entry into LLW disposal units in the humid eastern United States is through their covers. Two types of sub-surface features that may be constructed to enhance run-off (surface or sub-surface run-off) and thus reduce percolation are the resistive layer barrier, and the conductive layer barrier. The resistive layer barrier is the compacted soil or compacted clay layer and depends on compaction of permeable porous material to obtain low flow rates. The conductive layer barrier is a special case of the capillary barrier. Use is made of the capillary barrier phenomenon not only to increase the moisture content above an interface but to divert water away from the waste. During such diversion the water is at all times at negative capillary potential or under tension in the flow layer. A very effective barrier system might be constructed by placing a resistive barrier over a conductive barrier. Such a system must fail if appreciable subsidence takes place. An alternate procedure called bioengineering management utilizes engineered features at the surface (as opposed to the subsurface) to ensure adequate run-off. The engineered features are combined with stressed vegetation, that is, vegetation in an overdraft condition, to control deep percolation. (59 refs., 10 figs.)

  6. Development of Portable Flow-Through Electrochemical Sanitizing Unit to Generate Near Neutral Electrolyzed Water.

    Zhang, Jufang; Yang, Hongshun; Chan, Joel Zhi Yang

    2018-03-01

    We developed a portable flow-through, electrochemical sanitizing unit to produce near neutral pH electrolyzed water (producing NEW). Two methods of redirecting cathode yields back to the anode chamber and redirecting anode yields the cathode chamber were used. The NEW yields were evaluated, including: free available chlorine (FAC), oxidation-reduction potential (ORP), and pH. The performances of 2 electrodes (RuO 2 -IrO 2 /TiO 2 and IrO 2 -Ta 2 O 5 /TiO 2 ) were investigated. The unit produced NEW at pH 6.46 to 7.17, an ORP of 805.5 to 895.8 mV, and FAC of 3.7 to 82.0 mg/L. The NEW produced by redirecting cathode yields had stronger bactericidal effects than the NEW produced by redirecting anode yields or NEW produced by mixing the commercial unit's anode and cathode product (P portable flow-through, NEW-producing unit has great potential in a wide range of applications, such as organic farm, households, and small food industries. The examined sanitizing treatments showed effective control of Escherichia coli O157:H7 and Listeria monocytogenes. © 2018 Institute of Food Technologists®.

  7. Surveillance for waterborne disease and outbreaks associated with recreational water--United States, 2003-2004.

    Dziuban, Eric J; Liang, Jennifer L; Craun, Gunther F; Hill, Vincent; Yu, Patricia A; Painter, John; Moore, Matthew R; Calderon, Rebecca L; Roy, Sharon L; Beach, Michael J

    2006-12-22

    Since 1971, CDC, the U.S. Environmental Protection Agency, and the Council of State and Territorial Epidemiologists have collaboratively maintained the Waterborne Disease and Outbreak Surveillance System for collecting and reporting waterborne disease and outbreak (WBDO)-related data. In 1978, WBDOs associated with recreational water (natural and treated water) were added. This system is the primary source of data regarding the scope and effects of WBDOs in the United States. Data presented summarize WBDOs associated with recreational water that occurred during January 2003-December 2004 and one previously unreported outbreak from 2002. Public health departments in the states, territories, localities, and the Freely Associated States (i.e., the Republic of the Marshall Islands, the Federated States of Micronesia, and the Republic of Palau, formerly parts of the U.S.-administered Trust Territory of the Pacific Islands) have primary responsibility for detecting, investigating, and voluntarily reporting WBDOs to CDC. Although the surveillance system includes data for WBDOs associated with drinking water, recreational water, and water not intended for drinking, only cases and outbreaks associated with recreational water are summarized in this report. During 2003-2004, a total 62 WBDOs associated with recreational water were reported by 26 states and Guam. Illness occurred in 2,698 persons, resulting in 58 hospitalizations and one death. The median outbreak size was 14 persons (range: 1-617 persons). Of the 62 WBDOs, 30 (48.4%) were outbreaks of gastroenteritis that resulted from infectious agents, chemicals, or toxins; 13 (21.0%) were outbreaks of dermatitis; and seven (11.3%) were outbreaks of acute respiratory illness (ARI). The remaining 12 WBDOs resulted in primary amebic meningoencephalitis (n = one), meningitis (n = one), leptospirosis (n = one), otitis externa (n = one), and mixed illnesses (n = eight). WBDOs associated with gastroenteritis resulted in 1,945 (72

  8. Recommended reactor coolant water chemistry requirements for WWER-1000 units with 235U higher enriched fuel

    Dobrevski, I.; Zaharieva, N.

    2011-01-01

    The last decade worldwide experience of PWRs and WWERs confirms the trends for the improvement of the nuclear power industry electricity production through the implementation of high burn-up or high fuel duty, which are usually accompanied with the usage of UO 2 fuel with higher content of 235 U - 4.0% - 4.5% (5.0%). It was concluded that the onset of sub-cooled nucleate boiling (SNB) on the fuel cladding surfaces and the initial excess reactivity of the core are the primary and basic factors accompanying the implementation of uranium fuel with higher 235 U content, aiming extended fuel cycles and higher burn-up of the fuel in Pressurized Water Reactors. As main consequences of the presence of these factors the modifications of chemical / electrochemical environments of nuclear fuel cladding- and reactor coolant system- surfaces are evaluated. These conclusions are the reason for: 1) The determination of the choices of the type of fuel cladding materials in respect with their enough corrosion resistance to the specific fuel cladding environment, created by the presence of SNB; 2) The development and implementation of primary circuit water chemistry guidelines ensuring the necessary low corrosion rates of primary circuit materials and limitation of cladding deposition and out-of-core radioactivity buildup; 3) Implementation of additional neutron absorbers which allow enough decrease of the initial concentration of H 3 BO 3 in coolant, so that its neutralization will be possible with the permitted alkalising agent concentrations. In this paper the specific features of WWER-1000 units in Bulgarian Nuclear Power Plant; use of 235 U higher enriched fuel in the WWER-1000 reactors in the Kozloduy NPP; coolant water chemistry and radiochemistry plant data during the power operation period of the Kozloduy NPP Unit 5, 15 th fuel cycle; evaluation of the approaches and results by the conversion of the WWER-1000 Units at the Kozloduy NPP to the uranium fuel with 4.3% 235 U as

  9. Isoforms of purified methyltransferase from human blood platelets ...

    ... purification from normal human blood platelets have not been investigated, hence, the aim of this study was to purify, characterise the enzyme from human blood platelets and determine its possible role in phospholipid transmethylation. The plasma membranes were purified by velocity and sucrose gradient centrifugation ...

  10. Assay of partially purified glutamate dehydrogenase isolated from ...

    Glutamate dehydrogenase (E C 1.4.1.1) isolated from the seeds of asparagus beans was partially purified to a factor of 22 by dialysis after fractional precipitation with solid ammonium sulphate at 40 and 60% saturation. A specific activity of 11.78μmol min-1 mg-1 protein was calculated for the partially purified enzyme when ...

  11. Reproducible in vitro regeneration system for purifying sugarcane ...

    This procedure may be considered as one of the best ever published report on regeneration from in vitro grown plants to purify clones without subjecting the plants to field conditions and harvesting the mature cane. This technique was used to purify transgenic sugarcane plants carrying Bacillus thuringiensis gene.

  12. Respirators: Air Purifying, Self-Study, Course 40723

    Chochoms, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-21

    Respirators: Air Purifying Self-Study (COURSE 40723) is designed for Los Alamos National Laboratory (LANL) workers, support services subcontractors, and other LANL subcontractors who work under the LANL Respiratory Protection Program (RPP). This course also meets the air-purifying respirators (APRs) retraining requirement.

  13. Partially purified polygalacturonase from Aspergillus niger (SA6 ...

    Polygalacturonase (PG) was isolated from Aspergillus niger (A. niger) (SA6), partially purified and characterized. The PG showed two bands on SDS-PAGE suggesting an “endo and exo PG with apparent molecular weights of 35 and 40 KDa, respectively. It was purified 9-fold with a yield of 0.18% and specific activity of 246 ...

  14. Case study: evaluation of the performance of water treatment units by the use of tracer techniques

    Sebastian, C.; Maghella, G.; Mamani, E.

    2000-12-01

    Very often, water treatment systems do not reach the expected performance due to disturbances of hydraulic order, which cause malfunctioning in the flow through such systems. Tracer techniques have proved to be very useful to obtain information on the system or a part of it, by means of observation of the released tracer or observation of the released tracer during its progress into the system or at the output of the same. This paper is a report of the behavior of a set of both sand settlement unit and hydraulic flocculators in a potable water plant, through the analysis of radiotracers response curves or residence time distribution curves. The tracers released into the system consists in an aqueous solution of Iodine-131 with very low activity, in order to get a dynamic behave similar to the one of the fluid under investigation

  15. Units 3 and 4 steam generators new water level control system

    Dragoev, D.; Genov, St.

    2001-01-01

    The Steam Generator Water Level Control System is one of the most important for the normal operation systems, related to the safety and reliability of the units. The main upgrading objective for the SG level and SGWLC System modernization is to assure an automatic maintaining of the SG level within acceptable limits (below protections and interlocks) from 0% to 100% of the power in normal operation conditions and in case of transients followed by disturbances in the SG controlled parameters - level, steam flow, feedwater flow and/or pressure/temperature. To achieve this objective, the computerized controllers of new SG water level control system follows current computer control technology and is implemented together with replacement of the feedwater control valves and the needed I and C equipment. (author)

  16. Startup of Pumping Units in Process Water Supplies with Cooling Towers at Thermal and Nuclear Power Plants

    Berlin, V. V., E-mail: vberlin@rinet.ru; Murav’ev, O. A., E-mail: muraviov1954@mail.ru; Golubev, A. V., E-mail: electronik@inbox.ru [National Research University “Moscow State University of Civil Engineering,” (Russian Federation)

    2017-03-15

    Aspects of the startup of pumping units in the cooling and process water supply systems for thermal and nuclear power plants with cooling towers, the startup stages, and the limits imposed on the extreme parameters during transients are discussed.

  17. Grey water treatment by a continuous process of an electrocoagulation unit and a submerged membrane bioreactor system

    Bani-Melhem, Khalid; Smith, Edward

    2012-01-01

    This paper presents the performance of an integrated process consisting of an electro-coagulation (EC) unit and a submerged membrane bioreactor (SMBR) technology for grey water treatment. For comparison purposes, another SMBR process without

  18. Behavior of copper corrosion products in water loops of heat-exchange units

    Zarembo, V.I.; Kritskii, V.G.; Slobodov, A.A.; Puchkov, L.V.

    1989-01-01

    This communication is dedicated to an examination of copper corrosion products (CP) in the conditions of real aqueous-chemical regime (ACR) parameters. The deposition of these CP in steam-generating zones (up to 85% of their total amount) stimulate local types of corrosion. The solubility in Cu CP (Cu 2 O, CuO, Cu(OH) 2 )-water (H 2 O)-gas (H 2 , O 2 )-conditioning additives (HCl, KOH) systems was determined by computer modeling according to the minimum Gibbs energy criterion on the basis of selected and matched thermodynamic constants for various chemical forms of copper under standard conditions. As a result of the authors' calculations they obtained the solubilities in water of CuO, Cu 2 O and Cu(OH) 2 when changing the dosage of active gases from 0 to 10 -2 mole/kg of water, of acid or equal to that of saturated vapor of pure water. Thus, they were able to monitor the behavior of copper CP in conditions modeling those of real ACR in operating heat exchange units, including in conditions deviating from the standard

  19. Improved Sustainability through Novel Water Management Strategies for Strawberry Transplant Establishment in Florida, United States

    Emmanuel A. Torres-Quezada

    2012-12-01

    Full Text Available Establishing bare-root transplants in Florida, United States, is an inefficient water-consuming activity. Between 3500 and 5500 m3/ha are applied with sprinkler irrigation to lower temperatures around the transplant crown and aid early root development, but more than 97% of the water volume runs off the polyethylene-covered beds. Research has been conducted to evaluate the feasibility of producing containerized (plug short-day cultivar transplants under Florida conditions, the effect of continuous and intermittent low-volume sprinklers on transplant establishment and the use of kaolin clay to reduce stress on young transplants. Research results demonstrated that growers may have alternatives to reduce water use and pumping costs during strawberry transplant establishment by the following: (a plug transplants can be produced from mother plants from Florida’s subtropical weather without chilling conditioning and still be competitive in the winter market; (b using continuous and intermittent low-volume sprinkler irrigation saves between 16% and 33% of the water volumes for strawberry establishment; and (c using kaolin clay showed to be a low-cost (US$63/ha plus application costs investment to reduce irrigation volumes by at least 30%.

  20. Characterization of solids in the Three Mile Island Unit 2 reactor defueling water

    Campbell, D.O.

    1987-12-01

    Because of the impact of poor water clarity on defueling operations at the Three Mile Island Unit 2 Nuclear Power Station, a study was undertaken to characterize suspended particulates in the reactor defueling water. The examination included cascade filtration through Nuclepore filters of progressively smaller pore sizes, using three water samples obtained at different times and after varying degrees of clarification. The solids collected on the filters were examined with a scanning electron microscope and analyzed with energy-dispersive x-ray fluorescence. A wide variety of solids was observed, and 26 elements were detected. These included all the materials expected from the reactor system (uranium, zirconium, silver, cadmium, indium, iron, chromium, and nickel), chemicals and zeolites used to decontaminate the water (aluminum, silicon, sodium), common impurities (potassium, chlorine, sulfur, magnesium, calcium, and others), as well as some unexpected metals (molybdenum, manganese, bromine, and lead). There was also evidence for the presence of organic material. A diverse assortment of particles with widely varying surface properties was found to be present

  1. Real-time performance assessment and adaptive control for a water chiller unit in an HVAC system

    Bai, Jianbo; Li, Yang; Chen, Jianhao

    2018-02-01

    The paper proposes an adaptive control method for a water chiller unit in a HVAC system. Based on the minimum variance evaluation, the adaptive control method was used to realize better control of the water chiller unit. To verify the performance of the adaptive control method, the proposed method was compared with an a conventional PID controller, the simulation results showed that adaptive control method had superior control performance to that of the conventional PID controller.

  2. Study of radiation processes for purifying liquid effluent and the design of pilot plants

    Kon'kov, N.G.; Buslaeva, S.P.; Osipov, V.B.; Panin, Yu.A.; Solodikhina, L.D.; Upadyshev, L.B.; Karpukhin, V.F.; Fajngol'd, Z.L.

    1975-01-01

    The possibilities of purifying liquid effluent containing dyestuffs and various organic and biological pollutants with an accelerated electron beam of energy up to 0.7 MeV are examined. A laboratory plant has been erected for the stationary, continuous irradiation - with bubbling of air - of artificial and natural industrial effluent containing organic pollutants in concentrations of up to 2g/litre and the 5 SKh dye in concentrations of up to 220 mg/litre. The results are discussed of the experimental irradiation of artificial mixtures consisting of distilled water, organic pollutants and dyestuffs, and also of natural industrial effluents from an enterprise where antibiotics are produced and from textile mills. The results of the studies indicate that the physicochemical characteristics of effluents are improved. On the basis of these studies pilot plants with electron accelerators are being designed for a daily throughput of 15 000 m 3 of effluent from the production of antibiotics. The electron accelerators are of the transformer type (EhLV-1) with an energy of up to 0.7 MeV and a power of up to 40 kW. In addition, units with a daily throughput of 200 m 3 are being designed for the breakdown of cyanides in effluent by 60 Co. Such a unit consists of three reactors with centro-axial irradiators and solid cast-iron biological shielding. The dose-rate can be measured over a wide range, thanks to the use of spherical source holders. The sources have a total activity of 62 kCi. Calculations of the cost of the radiation treatment of effluent demonstrate the economic feasibility of the method

  3. Risk-informed Management of Water Infrastructure in the United States: History, Development, and Best Practices

    Wolfhope, J.

    2017-12-01

    This presentation will focus on the history, development, and best practices for evaluating the risks associated with the portfolio of water infrastructure in the United States. These practices have evolved from the early development of the Federal Guidelines for Dam Safety and the establishment of the National Dam Safety Program, to the most recent update of the Best Practices for Dam and Levee Risk Analysis jointly published by the U.S. Department of Interior Bureau of Reclamation and the U.S. Army Corps of Engineers. Since President Obama signed the Water Infrastructure Improvements for the Nation Act (WIIN) Act, on December 16, 2016, adding a new grant program under FEMA's National Dam Safety Program, the focus has been on establishing a risk-based priority system for use in identifying eligible high hazard potential dams for which grants may be made. Finally, the presentation provides thoughts on the future direction and priorities for managing the risk of dams and levees in the United States.

  4. Evaluating the Effectiveness of a Commercial Portable Air Purifier in Homes with Wood Burning Stoves: A Preliminary Study

    Julie F. Hart

    2011-01-01

    Full Text Available Wood burning for residential heating is prevalent in the Rocky Mountain regions of the United States. Studies have shown that wood stoves can be a significant source of PM2.5 within homes. In this study, the effectiveness of an electrostatic filter portable air purifier was evaluated (1 in a home where a wood stove was the sole heat source and (2 in a home where a wood stove was used as a supplemental heat source. Particle count concentrations in six particle sizes and particle mass concentrations in two particle sizes were measured for ten 12-hour purifier on and ten purifier off trials in each home. Particle count concentrations were reduced by 61–85 percent. Similar reductions were observed in particle mass concentrations. These findings, although limited to one season, suggest that a portable air purifier may effectively reduce indoor particulate matter concentrations associated with wood combustion during home heating.

  5. Burst protection device for largely cylindrical steam raising units, preferably of pressurized water nuclear power stations

    Mutzl, J.

    1978-01-01

    This burst protection device controls forces to be expected in an accident by resolving them into axial (vertical) and radial (horizontal) components, which are taken by a large number of elements stressed in tension. The steam raising unit is surrounded by a containment, but remains easily accessible. The containment consists of a steel jacket, lid and floor. Several cylindrical sections above one another form the steel jacket, which surrounds the steam raising unit with an intermediate insulating layer of concrete. The insulating concrete cylinder is of several times the thickness of the steel jacket, and also consists of cylindrical sections. An outer supporting ring for the lid and floor of the containment have outside diameters which project beyond the jacket. Prestressed circumferential vertical tension ropes between the supporting ring and floor take any additional tensional forces. The lid is domed with downward curvature towards the upper boiler dome. Internal bursting forces produce compressive stresses in the lid, which thus pass along its outside diameter into the surrounding ring. The lid, which is devided along one diameter, makes dismantling and access to the boiler easy even with a central steam pipe going upwards. The floor of the burst protection is also the floor of the steam raising unit. It is of several times the thickness of the tube floor, which, with its spacing above the floor forms the usual inlet and outlet space for the reactor cooling water. The main coolant pump installed there is driven by an external motor through a floor penetration. (HP) [de

  6. Ground-water recharge in the arid and semiarid southwestern United States

    Stonestrom, David A.; Constantz, Jim; Ferré, Ty P.A.; Leake, Stanley A.

    2007-01-01

    Ground-water recharge in the arid and semiarid southwestern United States results from the complex interplay of climate, geology, and vegetation across widely ranging spatial and temporal scales. Present-day recharge tends to be narrowly focused in time and space. Widespread water-table declines accompanied agricultural development during the twentieth century, demonstrating that sustainable ground-water supplies are not guaranteed when part of the extracted resource represents paleorecharge. Climatic controls on ground-water recharge range from seasonal cycles of summer monsoonal and winter frontal storms to multimillennial cycles of glacial and interglacial periods. Precipitation patterns reflect global-scale interactions among the oceans, atmosphere, and continents. Large-scale climatic influences associated with El Niño and Pacific Decadal Oscillations strongly, but irregularly, control weather in the study area, so that year-to-year variations in precipitation and ground-water recharge are large and difficult to predict. Proxy data indicate geologically recent periods of naturally occurring multidecadal droughts unlike any in the modern instrumental record. Any anthropogenically induced climate change will likely reduce ground-water recharge through diminished snowpack at higher elevations. Future changes in El Niño and monsoonal patterns, both crucial to precipitation in the study area, are highly uncertain in current models. Current land-use modifications influence ground-water recharge through vegetation, irrigation, and impermeable area. High mountain ranges bounding the study area—the San Bernadino Mountains and Sierra Nevada to the west, and the Wasatch and southern Colorado Rocky Mountains to the east—provide external geologic controls on ground-water recharge. Internal geologic controls stem from tectonic processes that led to numerous, variably connected alluvial-filled basins, exposure of extensive Paleozoic aquifers in mountainous recharge

  7. Unit Commitment Towards Decarbonized Network Facing Fixed and Stochastic Resources Applying Water Cycle Optimization

    Heba-Allah I. ElAzab

    2018-05-01

    Full Text Available This paper presents a trustworthy unit commitment study to schedule both Renewable Energy Resources (RERs with conventional power plants to potentially decarbonize the electrical network. The study has employed a system with three IEEE thermal (coal-fired power plants as dispatchable distributed generators, one wind plant, one solar plant as stochastic distributed generators, and Plug-in Electric Vehicles (PEVs which can work either loads or generators based on their charging schedule. This paper investigates the unit commitment scheduling objective to minimize the Combined Economic Emission Dispatch (CEED. To reduce combined emission costs, integrating more renewable energy resources (RER and PEVs, there is an essential need to decarbonize the existing system. Decarbonizing the system means reducing the percentage of CO2 emissions. The uncertain behavior of wind and solar energies causes imbalance penalty costs. PEVs are proposed to overcome the intermittent nature of wind and solar energies. It is important to optimally integrate and schedule stochastic resources including the wind and solar energies, and PEVs charge and discharge processes with dispatched resources; the three IEEE thermal (coal-fired power plants. The Water Cycle Optimization Algorithm (WCOA is an efficient and intelligent meta-heuristic technique employed to solve the economically emission dispatch problem for both scheduling dispatchable and stochastic resources. The goal of this study is to obtain the solution for unit commitment to minimize the combined cost function including CO2 emission costs applying the Water Cycle Optimization Algorithm (WCOA. To validate the WCOA technique, the results are compared with the results obtained from applying the Dynamic Programming (DP algorithm, which is considered as a conventional numerical technique, and with the Genetic Algorithm (GA as a meta-heuristic technique.

  8. Decadal-scale changes of pesticides in ground water of the United States, 1993-2003

    Bexfield, L.M.

    2008-01-01

    Pesticide data for ground water sampled across the United States between 1993-1995 and 2001-2003 by the U.S. Geological Survey National Water-Quality Assessment Program were evaluated for trends in detection frequency and concentration. The data analysis evaluated samples collected from a total of 362 wells located in 12 local well networks characterizing shallow ground water in agricultural areas and six local well networks characterizing the drinking water resource in areas of variable land use. Each well network was sampled once during 1993-1995 and once during 2001-2003. The networks provide an overview of conditions across a wide range of hydrogeologic settings and in major agricultural areas that vary in dominant crop type and pesticide use. Of about 80 pesticide compounds analyzed, only six compounds were detected in ground water from at least 10 wells during both sampling events. These compounds were the triazine herbicides atrazine, simazine, and prometon; the acetanilide herbicide metolachlor; the urea herbicide tebuthiuron; and an atrazine degradate, deethylatrazine (DEA). Observed concentrations of these compounds generally were spikes. In wells yielding detectable concentrations of atrazine, DEA, and prometon, concentrations were significantly lower (?? = 0.1) in 2001-2003 than in 1993-1995, whereas detection frequency of these compounds did not change significantly. Trends in atrazine concentrations at shallow wells in agricultural areas were found to be consistent overall with recent atrazine use data. Copyright ?? 2008 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.

  9. Optimum Returns from Greenhouse Vegetables under Water Quality and Risk Constraints in the United Arab Emirates

    Eihab Fathelrahman

    2017-04-01

    Full Text Available Greenhouses have been used in the United Arab Emirates (UAE to produce vegetables that contribute toward UAE food security, including offering fresh vegetable produce in the off-season. However, to manage such greenhouses, farmers face both technical and environmental limitations (i.e., high water scarcity, as well as vegetable market price instability. The objective of this study is to explore tradeoffs between returns (i.e., gross margin of selected vegetables (tomato, pepper, and cucumber, risk (deviation from gross margin means, and an environmental constraint (water salinity using a unique target MOTAD (minimization of total absolute deviations approach to support UAE farmer decision-making processes. The optimal target MOTAD solution included all three vegetables and no corner solution. The results showed tradeoffs between returns and risks, and confirmed that product diversification reduces overall risk. The analysis was consistent with farmer perceptions based on a survey of 78 producers in the region. The search for the optimal mix of vegetable production under UAE greenhouse conditions revealed that reduction in tomato production should be offset by an increase in cucumber production while maintaining a constant level of pepper production. In other words, risk is reduced as cucumber production increases due to the high level of tomato and lettuce price volatility as the alternative to cucumber. The results also demonstrated the importance of the water salinity environmental constraint, as it was found to have a positive marginal value in the optimal vegetable mix solution (i.e., important factor. Thus the optimal solution was highly sensitive to changes in the crop water salinity constraint. The study results also demonstrate that the target MOTAD approach is a suitable optimization methodology. As a practical approach, a decision-maker in the UAE can consider gross margin (total revenue-variable costs maximization with risk and water

  10. Superfund Record of Decision (EPA Region 6): United Nuclear Corporation, Mckinley County, New Mexico, ground-water operable unit (first remedial action) September 1988

    1988-01-01

    The United Nuclear Corporation (UNC) site is located approximately 17 miles northeast of Gallup, New Mexico in McKinley County. The site operated as a State-licensed uranium mill facility from June 1977 to May 1982. It includes an ore-processing mill (about 25 acres) and an unlined tailings pond area (about 100 acres). In July 1979, approximately 23 million gallons of tailings and pond water were released to a nearby river as a result of a dam breach in the tailings pond area. The site damage was repaired; however, attention was focused on ground-water contamination resulting from tailings seepage. Nevertheless, the offsite migration of radionuclides and chemical constituents from uranium milling byproduct materials into the ground water, as well as to surface water and air, are still principal threats at the site. The remedial action will address onsite ground water contamination. Source control and onsite surface reclamation will be implemented under the direction of the Nuclear Regulatory Commission and integrated with this ground water operable unit. The primary contaminants of concern affecting the ground water are metals including arsenic, and radioactive substances including radium-226/228 and gross alpha. The selected remedial action for the site is included

  11. Common Wet Chemical Agents for Purifying Multiwalled Carbon Nanotubes

    Rasel Das

    2014-01-01

    Full Text Available Purification and functionalization of multiwalled carbon nanotubes (MWCNTs are challenging but vital for their effective applications in various fields including water purification technologies, optoelectronics, biosensors, fuel cells, and electrode arrays. The currently available purification techniques, often complicated and time consuming, yielded shortened and curled MWCNTs that are not suitable for applications in certain fields such as membrane technologies, hybrid catalysis, optoelectronics, and sensor developments. Here we described the H2O2 synergy on the actions of HCl and KOH in purifying and functionalizing pristine MWCNTs. The method (HCl/H2O2 showed 100% purification yield as compared to HCl and KOH/H2O2 with purification yields 93.46 and 3.92%, respectively. We probed the findings using transmission electron microscope, energy dispersive X-ray spectroscope, attenuated total reflectance infrared spectroscope, Raman spectroscope, thermal gravimetric analysis, and X-ray powder diffraction. The study is a new avenue for simple, rapid, low cost, and scalable purification of pristine MWCNTs for application in versatile fields.

  12. Evaluation of water saving measures for mid-sized tourist lodging units: the case of Samos Island, Greece

    Eleftheria E. Klontza

    2016-06-01

    Full Text Available Hotel sector causes significant environmental stress in both natural and built up areas due to their consumption of water and energy. In addition, the production of large volumes of liquid and solid waste results in a significant environmental footprint. The use of water and energy by hotels is strongly linked (e.g. energy is consumed for hot water, operation of the pool, preparation of meals, etc. and usually referred to as the water – energy nexus. Thus, for big consumers like hotels, water and energy consumption should be addressed collectively as water-saving measures can lead to a reduction in energy consumption. The aim of this study is to assess the environmental performance of mid-sized hotel units by analyzing and quantifying their use of water. An analysis using a two-step approach was made of 8 accommodation facilities located on Samos Island, Greece: (i a mapping of water use by adopting an end-use approach, and then (ii an assessment of saving practices using three main criteria: savings, cost of investment and payback time. The preliminary results indicate that for small sized lodging units, water consumed inside the guest rooms accounts for the majority of all the water used and low-cost water saving measures and actions can reduce the pressure on water resources without disturbing guests, while increasing the financial profitability of a hotel.

  13. Co-occurrence of Photochemical and Microbiological Transformation Processes in Open-Water Unit Process Wetlands.

    Prasse, Carsten; Wenk, Jannis; Jasper, Justin T; Ternes, Thomas A; Sedlak, David L

    2015-12-15

    The fate of anthropogenic trace organic contaminants in surface waters can be complex due to the occurrence of multiple parallel and consecutive transformation processes. In this study, the removal of five antiviral drugs (abacavir, acyclovir, emtricitabine, lamivudine and zidovudine) via both bio- and phototransformation processes, was investigated in laboratory microcosm experiments simulating an open-water unit process wetland receiving municipal wastewater effluent. Phototransformation was the main removal mechanism for abacavir, zidovudine, and emtricitabine, with half-lives (t1/2,photo) in wetland water of 1.6, 7.6, and 25 h, respectively. In contrast, removal of acyclovir and lamivudine was mainly attributable to slower microbial processes (t1/2,bio = 74 and 120 h, respectively). Identification of transformation products revealed that bio- and phototransformation reactions took place at different moieties. For abacavir and zidovudine, rapid transformation was attributable to high reactivity of the cyclopropylamine and azido moieties, respectively. Despite substantial differences in kinetics of different antiviral drugs, biotransformation reactions mainly involved oxidation of hydroxyl groups to the corresponding carboxylic acids. Phototransformation rates of parent antiviral drugs and their biotransformation products were similar, indicating that prior exposure to microorganisms (e.g., in a wastewater treatment plant or a vegetated wetland) would not affect the rate of transformation of the part of the molecule susceptible to phototransformation. However, phototransformation strongly affected the rates of biotransformation of the hydroxyl groups, which in some cases resulted in greater persistence of phototransformation products.

  14. The Pattern Across the Continental United States of Evapotranspiration Variability Associated with Water Availability

    Koster, Randal D.; Salvucci, Guido D.; Rigden, Angela J.; Jung, Martin; Collatz, G. James; Schubert, Siegfried D.

    2015-01-01

    The spatial pattern across the continental United States of the interannual variance of warm season water-dependent evapotranspiration, a pattern of relevance to land-atmosphere feedback, cannot be measured directly. Alternative and indirect approaches to estimating the pattern, however, do exist, and given the uncertainty of each, we use several such approaches here. We first quantify the water dependent evapotranspiration variance pattern inherent in two derived evapotranspiration datasets available from the literature. We then search for the pattern in proxy geophysical variables (air temperature, stream flow, and NDVI) known to have strong ties to evapotranspiration. The variances inherent in all of the different (and mostly independent) data sources show some differences but are generally strongly consistent they all show a large variance signal down the center of the U.S., with lower variances toward the east and (for the most part) toward the west. The robustness of the pattern across the datasets suggests that it indeed represents the pattern operating in nature. Using Budykos hydroclimatic framework, we show that the pattern can largely be explained by the relative strength of water and energy controls on evapotranspiration across the continent.

  15. A comparison of three federal datasets for thermoelectric water withdrawals in the United States for 2010

    Harris, Melissa A.; Diehl, Timothy H.

    2017-01-01

    Historically, thermoelectric water withdrawal has been estimated by the Energy Information Administration (EIA) and the U.S. Geological Survey's (USGS) water-use compilations. Recently, the USGS developed models for estimating withdrawal at thermoelectric plants to provide estimates independent from plant operator-reported withdrawal data. This article compares three federal datasets of thermoelectric withdrawals for the United States in 2010: one based on the USGS water-use compilation, another based on EIA data, and the third based on USGS model-estimated data. The withdrawal data varied widely. Many plants had three different withdrawal values, and for approximately 54% of the plants the largest withdrawal value was twice the smallest, or larger. The causes of discrepancies among withdrawal estimates included definitional differences, definitional noise, and various nondefinitional causes. The uncertainty in national totals can be characterized by the range among the three datasets, from 5,640 m3/s (129 billion gallons per day [bgd]) to 6,954 m3/s (158 bgd), or by the aggregate difference between the smallest and largest values at each plant, from 4,014 m3/s (92 bgd) to 8,590 m3/s (196 bgd). When used to assess the accuracy of reported values, the USGS model estimates identify plants that need to be reviewed.

  16. Control of water infiltration into near surface LLW [low-level radioactive waste] disposal units

    Schulz, R.K.; Ridky, R.W.; O'Donnell, E.O.

    1990-12-01

    Three kinds of waste disposal unit covers a barriers to water infiltration are being investigated. They are: (1) resistive layer barrier, (2) conductive layer barrier, and (3) bioengineering management. The resistive layer barrier consists of compacted earthen material (e.g. clay). The conductive layer barrier consists of a conductive layer in conjunction with a capillary break. As long as unsaturated flow conditions are maintained the conductive layer will wick water around the capillary break. Below grade layered covers such as (1) and (2) will fail if there is appreciable subsidence of the cover. Remedial action for this kind of failure will be difficult. A surface cover, called bioengineering management, is meant to overcome this problem. The bioengineering management surface barrier is easily repairable if damaged by subsidence; therefore, it could be the system of choice under active subsidence conditions. The bioengineering management procedure also has been shown to be effective in dewatering saturated trenches and could be used for remedial action efforts. After cessation of subsidence, that procedure could be replaced by a resistive layer barrier, or perhaps even better, a resistive layer barrier/conductive layer barrier system. This latter system would then give long-term effective protection against water entry to waste and without institutional care. These various concepts are being assessed in six large (70ft x 45ft x 10ft each) lysimeters at Beltsville, Maryland. 6 refs., 20 figs.,

  17. Surface-water nutrient conditions and sources in the United States Pacific Northwest

    Wise, D.R.; Johnson, H.M.

    2011-01-01

    The SPAtially Referenced Regressions On Watershed attributes (SPARROW) model was used to perform an assessment of surface-water nutrient conditions and to identify important nutrient sources in watersheds of the Pacific Northwest region of the United States (U.S.) for the year 2002. Our models included variables representing nutrient sources as well as landscape characteristics that affect nutrient delivery to streams. Annual nutrient yields were higher in watersheds on the wetter, west side of the Cascade Range compared to watersheds on the drier, east side. High nutrient enrichment (relative to the U.S. Environmental Protection Agency's recommended nutrient criteria) was estimated in watersheds throughout the region. Forest land was generally the largest source of total nitrogen stream load and geologic material was generally the largest source of total phosphorus stream load generated within the 12,039 modeled watersheds. These results reflected the prevalence of these two natural sources and the low input from other nutrient sources across the region. However, the combined input from agriculture, point sources, and developed land, rather than natural nutrient sources, was responsible for most of the nutrient load discharged from many of the largest watersheds. Our results provided an understanding of the regional patterns in surface-water nutrient conditions and should be useful to environmental managers in future water-quality planning efforts.

  18. Diversity and antimicrobial resistance of Salmonella enterica isolates from surface water in Southeastern United States.

    Li, Baoguang; Vellidis, George; Liu, Huanli; Jay-Russell, Michele; Zhao, Shaohua; Hu, Zonglin; Wright, Anita; Elkins, Christopher A

    2014-10-01

    A study of prevalence, diversity, and antimicrobial resistance of Salmonella enterica in surface water in the southeastern United States was conducted. A new scheme was developed for recovery of Salmonella from irrigation pond water and compared with the FDA's Bacteriological Analytical Manual (8th ed., 2014) (BAM) method. Fifty-one isolates were recovered from 10 irrigation ponds in produce farms over a 2-year period; nine Salmonella serovars were identified by pulsed-field gel electrophoresis analysis, and the major serovar was Salmonella enterica serovar Newport (S. Newport, n = 29), followed by S. enterica serovar Enteritidis (n = 6), S. enterica serovar Muenchen (n = 4), S. enterica serovar Javiana (n = 3), S. enterica serovar Thompson (n = 2), and other serovars. It is noteworthy that the PulseNet patterns of some of the isolates were identical to those of the strains that were associated with the S. Thompson outbreaks in 2010, 2012, and 2013, S. Enteritidis outbreaks in 2011 and 2013, and an S. Javiana outbreak in 2012. Antimicrobial susceptibility testing confirmed 16 S. Newport isolates of the multidrug resistant-AmpC (MDR-AmpC) phenotype, which exhibited resistance to ampicillin, chloramphenicol, streptomycin, sulfamethoxazole, and tetracycline (ACSSuT), and to the 1st, 2nd, and 3rd generations of cephalosporins (cephalothin, amoxicillin-clavulanic acid, and ceftriaxone). Moreover, the S. Newport MDR-AmpC isolates had a PFGE pattern indistinguishable from the patterns of the isolates from clinical settings. These findings suggest that the irrigation water may be a potential source of contamination of Salmonella in fresh produce. The new Salmonella isolation scheme significantly increased recovery efficiency from 21.2 (36/170) to 29.4% (50/170) (P = 0.0002) and streamlined the turnaround time from 5 to 9 days with the BAM method to 4 days and thus may facilitate microbiological analysis of environmental water. Copyright © 2014, American Society for

  19. Light aging of reactive fuels purified by various methods

    Khodzhaeva, M G; Burtyshev, N Ya; Molodozhenyuk, T B; Ryabovda, N D

    1976-01-01

    A study of the effect of uv-radiation on aging of Fergana fuel TS-1 has been extended to the uv-effect on alkali-purified fuels (e.g., Krasnovodsk, Omsk, and Orsk TS-1), on hydro-purified (Syzran T-8, Syzran T-7, and Novokuybyshev T-7) and on adsorption-purified Fergana TS-1. The PRK-4 lamp was employed. Aging criteria were formation of insoluble gums, soluble gums separable on silicagel, acidity, and optical density. Fuels purified in the same manner aged practically identically; after 6 months storage the greatest gum formation was seen in the fuels Orsk TS-1 and Syzran T-8. 3 references, 1 figure, 1 table.

  20. Occurrence of human pharmaceuticals in water resources of the United States: A review

    Focazio, M.J.; Kolpin, D.W.; Furlong, E.T.

    2004-01-01

    The widespread environmental presence of some pharmaceuticals and other organic wastewater compounds has been documented globally (e.g. Buser et al. 1998; Ternes 1998; Stumpf et al.1999; Heberer et al. 2001; Kümmerer 2001; Ternes et al. 2001; Scheytt et al. 2001; Golet et al. 2002; Kolpin et al. 2002; Boyd et al. 2003; Metcalf et al. 2003). Recently, there have been several literature reviews and summary studies of the occurrence, fate, transport, and treatment of targeted human pharmaceuticals in wastewater effluent and associated environmental waters across the globe (e.g. Daughton and Ternes 1999; Sedlak et al. 2000; Suter and Giger 2000; Daughton and Jones-Lepp 2001; Jones et al. 2001; Heberer 2002; and Drewes et al. 2002). The occurrence of pharmaceutical compounds in water resources is explained by their ubiquitous use, excretion of large percentages of the mass consumed, and incomplete removal during wastewater treatment (Stumpf et al.1999). The recent increase in detection of trace concentrations (typically less than a part per billion) of pharmaceuticals in water resources across the globe reflects improvements in laboratory analytical methods (Sedlak et al. 2000) and the associated increases in field surveys. The detection of pharmaceutical compounds in large rivers in Europe and in the North Sea (Buser et al. 1998; Ternes 1998; Stumpf et al. 1999) highlighted the fact that highly soluble, trace organic compounds, such as pharmaceuticals, may escape removal in wastewater treatment, and the mixing and concentration of wastewaters through conventional wastewater treatment processes could provide a means of delivering these chemicals to environmental waters in a manner that would contaminate water resources on a large scale at trace levels (Richardson and Bowron 1985). In the United States, some of the first detections of a limited number of pharmaceutically active compounds or their transformation products were found in waters associated with landfill

  1. Quality of Water from Domestic Wells in Principal Aquifers of the United States, 1991-2004

    DeSimone, Leslie A.

    2009-01-01

    As part of the National Water-Quality Assessment Program of the U.S. Geological Survey (USGS), water samples were collected during 1991-2004 from domestic wells (private wells used for household drinking water) for analysis of drinking-water contaminants, where contaminants are considered, as defined by the Safe Drinking Water Act, to be all substances in water. Physical properties and the concentrations of major ions, trace elements, nutrients, radon, and organic compounds (pesticides and volatile organic compounds) were measured in as many as 2,167 wells; fecal indicator bacteria and radionuclides also were measured in some wells. The wells were located within major hydrogeologic settings of 30 regionally extensive aquifers used for water supply in the United States. One sample was collected from each well prior to any in-home treatment. Concentrations were compared to water-quality benchmarks for human health, either U.S. Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) for public water supplies or USGS Health-Based Screening Levels (HBSLs). No individual contaminant was present in concentrations greater than available health benchmarks in more than 8 percent of the sampled wells. Collectively, however, about 23 percent of wells had at least 1 contaminant present at concentrations greater than an MCL or HBSL, based on analysis of samples from 1,389 wells in which most contaminants were measured. Radon, nitrate, several trace elements, fluoride, gross alpha- and beta-particle radioactivity, and fecal indicator bacteria were found most frequently (in one or more percent of wells) at concentrations greater than benchmarks and, thus, are of potential concern for human health. Radon concentrations were greater than the lower of two proposed MCLs (300 picocuries per liter or pCi/L) in about 65 percent of the wells and greater than the higher proposed MCL (4,000 pCi/L) in about 4 percent of wells. Nitrate, arsenic, manganese, strontium, and

  2. Failure analysis of cracked head spray piping from the Dresden Unit 2 Boiling Water Reactor

    Diercks, D.R.; Dragel, G.M.

    1983-07-01

    Several sections of Type 304 stainless steel head spray piping, 6.25 cm (2.5 in.) in diameter, from the Dresden Unit 2 Boiling Water Reactor were examined to determine the nature and causes of coolant leakages detected during hydrostatic tests. Extensive pitting was observed on the outside surface of the piping, and three cracks, all located at a helical stripe apparently rubbed onto the outer surface of the piping, were also noted. Metallographic examination revealed that the cracking had initiated at the outer surface of the pipe, and showed it to be transgranular and highly branched, characteristic of chloride stress corrosion cracking. The surface pitting also appeared to have been caused by chlorides. A scanning electron microprobe x-ray analysis of the corrosion product in the cracks confirmed the presence of chlorides and also indicated the presence of calcium

  3. Design and fabrication of water control unit for IASCC irradiation test

    Mori, Yuichiro; Takeuchi, Yutaka; Matsunami, Kiyotaka; Kosaki, Kazuhiko; Suzuki, Tomio; Hayashi, Motomitsu; Ide, Kiyoshi

    2004-01-01

    In relation to the aging of LWR, the Irradiation Assisted Stress Corrosion Cracking (IASCC) has been regarded as a significant and urgent issue for the reliability of in-core components of LWR, therefore the irradiation research project which was planned by Nuclear and Industrial Safety Agency is now being done under the cooperation of Industry-Government-Academia such as Japan Nuclear Energy Safety Organization, Institute of Research and Innovation (IRI), Central Research Institute of Electric Power Industry, Japan Atomic Energy Research Institute (JAERI), power companies, makers of LWR, and universities. Then at Japan Material Testing Reactor (JMTR) of JAERI, the irradiation test of the material for BWR is being carried out. This paper describes the introduction about the Water Control Unit (WCU) for IASCC irradiation test. The WCU was designed and installed into JMTR by Kawasaki Heavy Industries, LTD, based on the order from JAERI, IRI, and so on. (author)

  4. Design and study of water supply system for supercritical unit boiler in thermal power station

    Du, Zenghui

    2018-04-01

    In order to design and optimize the boiler feed water system of supercritical unit, the establishment of a highly accurate controlled object model and its dynamic characteristics are prerequisites for developing a perfect thermal control system. In this paper, the method of mechanism modeling often leads to large systematic errors. Aiming at the information contained in the historical operation data of the boiler typical thermal system, the modern intelligent identification method to establish a high-precision quantitative model is used. This method avoids the difficulties caused by the disturbance experiment modeling for the actual system in the field, and provides a strong reference for the design and optimization of the thermal automation control system in the thermal power plant.

  5. Rancang Bangun Perangkat Lunak Unit Kontrol Alat Ukur Sudu Cross Flow Water Turbine Berbasis Pengolahan Citra

    Eka Marliana

    2014-09-01

    Full Text Available Seiring dengan berkembangnya teknologi informasi dan komunikasi, alat ukur mengalami perkembangan yang cukup signifikan. Salah satu bentuk perkembangannya adalah dengan dibuatnya alat ukur sudu cross flow water turbine berbasis pengolahan citra oleh Rusweki dan Pradnyana pada tahun 2013. Namun, alat ukur ini masih dioperasikan secara manual. Tugas akhir ini bertujuan untuk melakukan pengembangan terhadap alat tersebut, khususnya dibidang rancang bangun perangkat lunak untuk unit kontrolnya. Metodologi yang diterapkan dalam tugas akhir ini yang pertama adalah mempelajari hal-hal yang berkaitan dengan topik bahasan dari berbagai literatur. Langkah kedua adalah menetukan perumusan masalah dan menentukan metode pembuatan perangkat lunak. Ketiga, pembuatan perangkat lunak dan verifikasi. Pada penelitian ini telah berhasil dirancang perangkat lunak untuk unit kontrol alat ukur sudu CFWT berbasis pengolahan citra. Berdasarkan hasil kalibrasi sensor inframerah Sharp GP2Y0A21 didapatkan bahwa nilai jarak adalah sama dengan 178924.57 dibagi dengan nilai output ADC desimal pangkat 1.08. Selisih maksimal antara jarak input dan jarak tempuh motor adalah 0.5mm, dan jarak kontrol antara 130-400mm. Dengn demikian, metode pengukuran menggunakan alat ini akan lebih mudah dan cermat, karena selain dapat mengukur benda dengan bentuk yang kompleks mngurangi resiko keausan benda an lebih teliti, juga bisa diakukan dengan mudah serta cepat karena adanya sistem kontrol

  6. [Calculating the optimum size of a hemodialysis unit based on infrastructure potential].

    Avila-Palomares, Paula; López-Cervantes, Malaquías; Durán-Arenas, Luis

    2010-01-01

    To estimate the optimum size for hemodialysis units to maximize production given capital constraints. A national study in Mexico was conducted in 2009. Three possible methods for estimating a units optimum size were analyzed: hemodialysis services production under monopolistic market, under a perfect competitive market and production maximization given capital constraints. The third method was considered best based on the assumptions made in this paper; an optimal size unit should have 16 dialyzers (15 active and one back up dialyzer) and a purifier system able to supply all. It also requires one nephrologist, five nurses per shift, considering four shifts per day. Empirical evidence shows serious inefficiencies in the operation of units throughout the country. Most units fail to maximize production due to not fully utilizing equipment and personnel, particularly their water purifier potential which happens to be the most expensive asset for these units.

  7. Loss of Power and Water Hammer Event at San Onofre, Unit 1, on November 21, 1985

    1986-01-01

    On November 21, 1985, Southern California Edison's Onofre Nuclear Generating Station, Unit 1, located south of San Clemente, California, experienced a partial loss of inplant ac electrical power while the plant was operating at 60% power. Following a manual reactor trip, the plant lost all inplant ac power for 4 minutes and experienced a severe incidence of water hammer in the feedwater system which caused a leak, damaged plant equipment, and challenged the integrity of the plant's heat sink. The most significant aspect of the event involved the failure of five safety-related check valves in the feed-water system whose failure occurred in less than year, without detection, and jeopardized the integrity of safety systems. The event involved a number of equipment malfunctions, operator errors, and procedural deficiencies. This report documents the findings and conclusions of an NRC Incident Investigation Team sent to San Onofre by the NRC Executive Director for Operations in conformance with NRC's recently established Incident Investigation Program

  8. A new chemical formulation for control of dental unit water line contamination: An 'in vitro' and clinical 'study'

    Dolci Giovanni

    2002-02-01

    Full Text Available Abstract Background Water delivered by dental units during routine dental practice is highly contaminated. The aim of this study is to evaluate the efficacy of a new chemical solution flushed through Dental Unit Water Lines (DUWL for the control of contamination inside dental units. Materials and methods Six old dental units equipped with a device designed to automatically flush disinfecting solutions through the water system (Castellini Autosteril were selected. Water samples from DUWL effluents were collected in each dental unit for 10 randomly selected days, before and after a 5 minute DUWL disinfecting cycle with TetraAcetylEthileneDiamine (TAED and persalt (Ster4spray produced by Farmec spa, and distributed by Castellini spa. Water samples were plated in R2A Agar and cultured at room temperature for 7 days, and the total number of heterotrophic microorganisms counted and expressed in Log10 CFU/mL A general linear model was fitted and multiple regression ANOVA for repeated measures was used for the statistical analysis. Results The mean contamination in DUWL effluent at baseline was 5.45 ± 0.35 CFU/mL (range 4.79 to 5.93 CFU/mL. When water samples were tested "in vitro" against the chemical, no growth of heterotrophic bacteria was detected after a 5 minute contact in any of the water samples tested. After undergoing a 5 minute disinfecting cycle with the chemical, DUWL mean contamination in water effluents was 2.01 ± 0.32 CFU/mL (range 1.30 to 2.74 CFU/mL (significant difference with respect to baseline. Conclusions An inbetween patient disinfecting procedure consisting of flushing DUWL with TAED and persalt equivalent to 0.26% peracetic acid could be useful in routine dental practice for cross-contamination control.

  9. Water Purification

    1994-01-01

    The Vision Catalyst Purifier employs the basic technology developed by NASA to purify water aboard the Apollo spacecraft. However, it also uses an "erosion" technique. The purifier kills bacteria, viruses, and algae by "catalytic corrosion." A cartridge contains a silver-impregnated alumina bed with a large surface area. The catalyst bed converts oxygen in a pool of water to its most oxidative state, killing over 99 percent of the bacteria within five seconds. The cartridge also releases into the pool low levels of ionic silver and copper through a controlled process of erosion. Because the water becomes electrochemically active, no electricity is required.

  10. Estimating virus occurrence using Bayesian modeling in multiple drinking water systems of the United States

    Drinking water treatment plants rely on purification of contaminated source waters to provide communities with potable water. One group of possible contaminants are enteric viruses. Measurement of viral quantities in environmental water systems are often performed using polymeras...

  11. Analysis of risk reduction measures applied to shared essential service water systems at multi-unit sites

    Kohut, P.; Musicki, Z.; Fitzpatrick, R.

    1991-06-01

    This report summarizes a study performed by Brookhaven National Laboratory for the US Nuclear Regulatory Commission in support of the resolution of NRC Generic Issue 130. GI-130 is concerned with the potential core damage vulnerability resulting from failure of the emergency service water (ESW) system in selected multiplant units. These multiplant units are all twin pressurized water reactor designs that have only two ESW pumps per unit (one per train) backed up by a unit crosstie capability. This generic issue applies to seven US sites (14 plants). The study established and analyzed the core damage vulnerability and identified potential improvements for the ESW system. It obtained generic estimates of the risk reduction potential and cost effectiveness of each potential improvement. The analysis also investigated the cost/benefit aspects of selected combinations of potential improvements. 4 figs., 62 tabs

  12. Qualidade da água utilizada para equipamentos de hemodiálise em Unidade de Terapia Intensiva / Water quality of hemodialysis systems at Intensive Care Unit

    Simone Aparecida Galerani Mossini

    2014-08-01

    Full Text Available Existem critérios e regulamentos para a avaliação da qualidade da água em serviços de unidade de terapia ambulatorial e recomendações específicas para os procedimentos realizados em unidades de terapia intensiva (UTI. Um estudo exploratório foi conduzido em equipamentos de hemodiálise em UTI, em uma cidade do Sul do Brasil. Amostras de água foram coletadas da rede de abastecimento público e pós-osmose reversa associa-da a dois aparelhos de hemodiálise, entre janeiro e junho de 2011. Espectrometria de emissão óptica com fonte de plasma indutivamente acoplado (ICP OES foi utilizada para análise de metais em níveis de traços. Análises bacteriológicas foram realizadas para pesquisa de bactérias heterotróficas. Os dados obtidos mostraram que as concentrações dos metais não excederam os limites estabelecidos pela legislação. A análise bacterioló-gica da água para hemodiálise resultou em contagem inferior a 200 UFC/mL, em todos os meses avaliados, com exceção do mês de fevereiro. Os resultados obtidos corroboram o fato de que a manutenção e os cuidados necessários com a água para o tratamento dialítico têm sido efetivos. A prevenção de complicações decorrentes de contaminantes químicos ou microbiológicos na água para hemodiálise em UTI requer uma atenção cons-tante, uma vez que as condições dos pacientes são diferentes daquelas encontradas em atendimento ambulatorial. --------------------------------------------------------------------- There are rules and regulations for assessment of water quality services in ambulatory care unit and specific recommendations for the procedures performed in intensive care units (ICU services. An exploratory study was conducted at hemodialysis equipment in ICU in a Southern Brazil city. Water samples were directly collected from the network public supply and from post-reverse osmosis associated with hemodialysis equipaments, monthly from January to June 2011. Mass

  13. Development of a Microwave Regenerative Sorbent-Based Hydrogen Purifier

    Wheeler, Richard R., Jr.; Dewberry, Ross H.; McCurry, Bryan D.; Abney, Morgan B.; Greenwood, Zachary W.

    2016-01-01

    This paper describes the design and fabrication of a Microwave Regenerative Sorbent-based Hydrogen Purifier (MRSHP). This unique microwave powered technology was developed for the purification of a hydrogen stream produced by the Plasma Pyrolysis Assembly (PPA). The PPA is a hydrogen recovery (from methane) post processor for NASA's Sabatier-based carbon dioxide reduction process. Embodied in the Carbon dioxide Reduction Assembly (CRA), currently aboard the International Space Station (ISS), the Sabatier reaction employs hydrogen to catalytically recover oxygen, in the form of water, from respiratory carbon dioxide produced by the crew. This same approach is base-lined for future service in the Air Revitalization system on extended missions into deep space where resupply is not practical. Accordingly, manned exploration to Mars may only become feasible with further closure of the air loop as afforded by the greater hydrogen recovery permitted by the PPA with subsequent hydrogen purification. By utilizing the well-known high sorbate loading capacity of molecular sieve 13x, coupled with microwave dielectric heating phenomenon, MRSHP technology is employed as a regenerative filter for a contaminated hydrogen gas stream. By design, freshly regenerated molecular sieve 13x contained in the MRSHP will remove contaminants from the effluent of a 1-CM scale PPA for several hours prior to breakthrough. By reversing flow and pulling a relative vacuum the MRSHP prototype then uses 2.45 GHz microwave power, applied through a novel coaxial antenna array, to rapidly heat the sorbent bed and drive off the contaminants in a short duration vacuum/thermal contaminant desorption step. Finally, following rapid cooling via room temperature cold plates, the MRSHP is again ready to serve as a hydrogen filter.

  14. Pseudomonas aeruginosa outbreak in a pediatric oncology care unit caused by an errant water jet into contaminated siphons.

    Schneider, Henriette; Geginat, Gernot; Hogardt, Michael; Kramer, Alexandra; Dürken, Matthias; Schroten, Horst; Tenenbaum, Tobias

    2012-06-01

    We analyzed an outbreak of invasive infections with an exotoxin U positive Pseudomonas aeruginosa strain within a pediatric oncology care unit. Environmental sampling and molecular characterization of the Pseudomonas aeruginosa strains led to identification of the outbreak source. An errant water jet into the sink within patient rooms was observed. Optimized outbreak management resulted in an abundance of further Pseudomonas aeruginosa infections within the pediatric oncology care unit.

  15. Decree 328/003. Is approve the organizational structure reformulation project of the regulatory unit of Unit 006 Energy and water services of subsection 02 Presidency of the Republic

    2003-01-01

    This decree approve the organizational structure project of The regulatory energy and water services ( URSEA). This unit is responsible for monitoring the activities related to electricity, gas, drinking water, sanitation and oil, fuel and other hydrocarbon derivatives

  16. Flowsheet development studies for the decontamination of high-activity-level water at Three Mile Island Unit 2

    Collins, E.D.; Bigelow, J.E.; Campbell, D.O.; King, L.J.; Knauer, J.B.

    1980-01-01

    Several chemical processing flowsheets were considered for the decontamination of high-activity-level water at the Three Mile Island (TMI) Unit 2. A zeolite ion exchange process was evaluated and recommended for absorption of the bulk of the highly radioactive cesium and strontium. Standard organic ion-exchange resins were selected to remove the remaining traces of radioactive nuclides (except tritium which cannot be removed by any practical process). Process conditions were evaluated using both synthetic, tracer-level solutions and samples of actual, high-activity level water from TMI Unit 2

  17. Some aspects of correction additions optimisation of water chemistry regime of Kozloduy NPP power units 3 and 4

    Topalova, I.

    2005-01-01

    Optimization of the water-chemistry regime is a major corrective measure for minimization of the corrosion processes of the nuclear power unit equipment. Research done in NPP Kozloduy III - IV power units concerning the migration of the corrosion products in the water of secondary circuit as well as the connection between corrosion processes and fluctuation in parameters of the applied water-chemistry regime are reported. Analysis of the dependences obtained lead to conclusions for optimization of the water chemistry regime of secondary circuit and minimization of the corrosion processes and improvement of corrosion condition of metal surfaces. The research is done for the circuit of each of the 8 turbines of the two power units for a period of 10 days. Data received is quantitatively representative /40-50 points/ for performing of analysis and reaching certain conclusions for the water chemistry regime and development of corrosion processes. Dependence of iron and copper concentration in the work medium on the pH, ammonia and hydrazine concentration as well as the dependence of pH on ammonia concentration in case of different quantity and composition of corrosion products on the different power units' equipment metal surfaces are shown. (author)

  18. Analysis of chiller units capacity for different heat loads considering variation of ambient air and cooling water temperature

    Coman, Aurelia Camelia; Tenescu, Mircea

    2010-01-01

    The paper purpose is to analyze the chiller units capacity to determine whether they can cope with high air and cooling water temperatures during summer time to remove heat loads imposed from Heating, Ventilation and Air Conditioning (HVAC) units in a CANDU 6 Nuclear Power Plant. The starting point is calculation of the overall heat transfer coefficient at the evaporator and condenser. They are used in heat balance equations of heat exchangers. A mathematical model was developed that simulates the refrigeration cycle to assess the response of chilled water system and its performance at different heat loads. In this analysis there were calculated values for inlet/outlet chilled water temperature and the refrigerant cycle thermodynamic parameters (condenser and evaporator pressure/temperature, refrigerant mass flowrate, refrigerant quality at the evaporator, refrigerant vapour superheated temperature at the compressor outlet, refrigerant subcooled temperature at the condenser outlet). To find the adequate functioning parameters of the installation, the MathCAD 13 software was used in all cases analyzed. The behaviour of the chiller units was investigated by examining the variation of three basic parameters, namely: - cooling water (river water) temperature; - air temperature; - heat load. The simultaneous variation of these three independent parameters allows to identify the actual chillers unit operating point (including chiller trip). (authors)

  19. Lack of cytotoxicity by Trustwater Ecasol™ used to maintain good quality dental unit waterline output water in keratinocyte monolayer and reconstituted human oral epithelial tissue models.

    Boyle, M A

    2010-11-01

    We previously showed that residual treatment of dental chair unit (DCU) supply water using the electrochemically-activated solution Trustwater Ecasol™ (2.5 ppm) provided an effective long-term solution to the problem of dental unit waterline (DUWL) biofilm resulting in DUWL output water quality consistently superior to potable water.

  20. Robust sparse image reconstruction of radio interferometric observations with PURIFY

    Pratley, Luke; McEwen, Jason D.; d'Avezac, Mayeul; Carrillo, Rafael E.; Onose, Alexandru; Wiaux, Yves

    2018-01-01

    Next-generation radio interferometers, such as the Square Kilometre Array, will revolutionize our understanding of the Universe through their unprecedented sensitivity and resolution. However, to realize these goals significant challenges in image and data processing need to be overcome. The standard methods in radio interferometry for reconstructing images, such as CLEAN, have served the community well over the last few decades and have survived largely because they are pragmatic. However, they produce reconstructed interferometric images that are limited in quality and scalability for big data. In this work, we apply and evaluate alternative interferometric reconstruction methods that make use of state-of-the-art sparse image reconstruction algorithms motivated by compressive sensing, which have been implemented in the PURIFY software package. In particular, we implement and apply the proximal alternating direction method of multipliers algorithm presented in a recent article. First, we assess the impact of the interpolation kernel used to perform gridding and degridding on sparse image reconstruction. We find that the Kaiser-Bessel interpolation kernel performs as well as prolate spheroidal wave functions while providing a computational saving and an analytic form. Secondly, we apply PURIFY to real interferometric observations from the Very Large Array and the Australia Telescope Compact Array and find that images recovered by PURIFY are of higher quality than those recovered by CLEAN. Thirdly, we discuss how PURIFY reconstructions exhibit additional advantages over those recovered by CLEAN. The latest version of PURIFY, with developments presented in this work, is made publicly available.

  1. Closure plan for the Test Area North-726 chromate water storage and Test Area North-726A chromate treatment units

    Smith, P.J.; Van Brunt, K.M.

    1992-11-01

    This document describes the proposed plan for closure of the Test Area North-726 chromate water storage and Test Area North-726A chromate treatment units at the Idaho National Engineering Laboratory in accordance with the Resource Conservation and Recovery Act interim status closure requirements. The location, size, capacity, and history of the units are described, and their current status is discussed. The units will be closed by treating remaining waste in storage, followed by thorough decontamination of the systems. Sufficient sampling and analysis, and documentation of all activities will be performed to demonstrate clean closure

  2. Sampling and analysis plan for treatment water and creek water for the Lower East Fork Poplar Creek Operable Unit, Oak Ridge, Tennessee

    1996-04-01

    This document provides the Environmental Restoration Program with information about the methodology, organizational structure, quality assurance and health and safety practices to be employed during the water sampling and analysis activities associated with the remediation of the Lower East Fork Poplar Creek Operable Unit during remediation of the National Oceanic and Atmospheric Administration and Bruner sites

  3. Sampling and analysis plan for treatment water and creek water for the Lower East Fork Poplar Creek Operable Unit, Oak Ridge, Tennessee

    NONE

    1996-04-01

    This document provides the Environmental Restoration Program with information about the methodology, organizational structure, quality assurance and health and safety practices to be employed during the water sampling and analysis activities associated with the remediation of the Lower East Fork Poplar Creek Operable Unit during remediation of the National Oceanic and Atmospheric Administration and Bruner sites.

  4. The issue of radon and daughters in water and in air detection using the detection unit 'YAPMARE'

    Thinova, L.; Trojek, T.; Kunka, A.; Maly, P.; Blazek, K.; Notaristefani, F. de; Moucka, L.

    2004-01-01

    The specialized detection unit YAPMARE was developed by company CRYTUR Ltd. The main part of the detection unit is a detection probe based on a 100 mm x 25 mm diam. YAP:Ce detector, made of monocrystalline YAP:Ce (chemical formula is YAlO 3 doped Ce) grown by Crytur Ltd. YAP:Ce crystal advantages are in chemical resistance, good mechanical properties, nonhygroscopicity and ease of polishing; remainder of radionuclides deposited on the Teflon surface can be easily deactivated using HCl acid. The detection unit was developed for 222 Rn and its daughter's measurement in water under extreme conditions (pressure, temperature and acidity) to obtain additional information about flow dynamics in Earth crust. The detection volume for water (or air) is 12 ml and in this case the measured medium covers approximately 95% of the crystal surface, while the remaining 5% is a spiral groove machined into the Teflon enclosure (used as a reflector). Spectrometry results of the measurement are an advantage for data processing. The main points of 'YAPMARE' unit testing are as follows: Methodology of water sample collection, defining the optimum measurement time interval; Energetic stability monitoring; Gamma ray energetic calibration using etalons and natural radioactive rock; Alpha ray energetic calibration using dry (air) standards of 222 Rn and 220 Rn, with peaks in alpha spectrum identification; The gamma background elimination during measurement and in data processing; Measuring the high 222 Rn water activity (Svornost mine in Jachymov - radon activity 17 kBq/l); Probe calibration for radon-in-water determination (using fresh water from a drilled well in Lounovice near Prague and using a 222 Rn water standard). Due to the large crystal volume all measurements were conducted inside a Pb shield 25 mm thick. The water alpha activity was also monitored using radon monitor RADIM 4. All results of testing will be presented. (author)

  5. "Using Satellite Remote Sensing to Derive Numeric Criteria in Coastal and Inland Waters of the United States"

    Crawford, T. N.; Schaeffer, B. A.

    2016-12-01

    Anthropogenic nutrient pollution is a major stressor of aquatic ecosystems around the world. In the United States, states and tribes can adopt numeric water quality values (i.e. criteria) into their water quality management standards to protect aquatic life from eutrophication impacts. However, budget and resource constraints have limited the ability of many states and tribes to collect the water quality monitoring data needed to derive numeric criteria. Over the last few decades, satellite technology has provided water quality measurements on a global scale over long time periods. Water quality managers are finding the data provided by satellite technology useful in managing eutrophication impacts in coastal waters, estuaries, lakes, and reservoirs. In recent years EPA has worked with states and tribes to derive remotely sensed numeric Chl-a criteria for coastal waters with limited field-based data. This approach is now being expanded and used to derive Chl-a criteria in freshwater systems across the United States. This presentation will cover EPA's approach to derive numeric Chl-a criteria using satellite remote sensing, recommendations to improve satellite sensors to expand applications, potential areas of interest, and the challenges of using remote sensing to establish water quality management goals, as well as provide a case in which this approach has been applied.

  6. Challenges in setting up a potable water supply system in a United Nations peacekeeping mission: the South Sudan experience.

    Hazra, Aniruddha

    2013-01-01

    A United Nations peacekeeping contingent was deployed in the conflict affected areas of South Sudan with inadequate environmental sanitation, lack of clean drinking water and a heightened risk of water-borne diseases. In the immediate post-deployment phase, the contingent-owned water purification system was pressed into service. However, laboratory analyses of processed water revealed its unsuitability for human consumption. A systematic, sanitary survey was conducted to identify the shortcomings in the water supply system's ability to provide potable water. Under field conditions, the 'H2S method' was used to detect faecal contamination of drinking water. The raw water from the only available source, the White Nile River, was highly turbid and contaminated by intestinal and other pathogens due to an unprotected watershed. Water sterilizing powder was not readily available in the local area to replenish the existing stocks that had deteriorated during the long transit period from the troop contributing country. The water pipelines that had been laid along the ground, under water-logged conditions, were prone to microbial recontamination due to leakages in the network. The critical evaluation of the water supply system and necessary modifications in the purification process, based upon locally available options, yielded safe drinking water. Provision of safe drinking water in the mission area requires an in-depth analysis of prevailing conditions and appropriate planning in the pre-deployment phase. The chemicals for water purification should be procured through UN sources via a 'letter of assist' request from the troop contributor. Copyright © 2012 Elsevier GmbH. All rights reserved.

  7. Review of the desalinated water market in France for small units; Apercu sur le marche de l'eau dessalee en France pour de petites unites

    Dutheil, F; Malissen, M [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    On the initiative of and in close collaboration with the Commissariat a l'Energie Atomique, the Societe pour la Conversion et le Developpement Industriel (SODIC) has carried out a very general study of the coastal regions of France in which the short, medium and long-term prospects of the demand for water, and the cost of the necessary supplies, could possibly make desalination units of 3 000 to 10 000 m3/day competitive. So far this general enquiry, which went into detail on some particular aspects, has not revealed any very clear possibilities in this respect, except in the case of the small islands, and of units of much lower capacity, as well as that of large units on the coast, which would benefit from the size effect. However the probable difference between the cost of desalinated water and the high selling price already applying in a small number of coastal regions is relatively small. It might therefore be worthwhile and relatively inexpensive to install an experimental desalination unit in the near future. (author) [French] A l'initiative du Commissariat a l'Energie Atomique et en etroite liaison avec lui, la Societe pour la Conversion et le Developpement Industriel (SODIC) a effectue une etude tres generale des zones cotieres francaises dans lesquelles les perspectives de la demande d'eau a court, moyen et long terme et le cout des approvisionnements necessaires, pourraient eventuellement faire apparaitre comme competitives des unites de dessalement de 3 a 10 000 m{sup 3}/jour. Jusqu'ici, cette enquete generale, d'ailleurs approfondie sur quelques points particuliers, n'a pas fait apparaitre de possibilites tres nettes a cet egard. Le cas des petites iles, et pour des unites de bien plus faible capacite, demeure reserve ainsi que, sur les zones cotieres, celui de grandes unites qui beneficieraient de l'effet de taille. Toutefois, l'ecart probable entre le cout de l'eau dessalee et le prix de vente eleve deja observe dans un petit nombre de zones cotieres

  8. AN EXPERIENCE OF HANDLING MICROBIAL CONTAMINATION OF PRODUCT WATER AT A HAEMODIALYSIS UNIT IN NORTH KARNATAKA OF INDIA

    Archana Aravindrao Dambal

    2017-09-01

    Full Text Available BACKGROUND Dialysis units need regular prophylactic disinfection of the dialysis water production and distribution circuit without which there can be chronic inflammation among patients using the facility. The aim of the study is to present here our experience in containing an episode of microbial contamination of dialysis water. MATERIALS AND METHODS Our haemodialysis unit had a single pass reverse osmosis plant with facility for pretreatment of raw water and a distribution loop of medical grade PVC (polyvinyl chloride feeding haemodialysis machines, bicarbonate preparation and dialyser reprocessing areas. After installation, the Reverse Osmosis (RO membranes and distribution loop were disinfected every fortnight using formalin. Cultures of product water were sent from various sites in the product water loop every month. RESULTS From January to April 2011, 15 water samples out of 52 water samples grew Pseudomonas aeruginosa with a colony count over 200 Colony-Forming Units (CFU. The average monthly number of haemodialysis was reduced from 84.75 to 65. Two patients had intradialytic pyrexia and two others had mild lower respiratory infection. So, the reverse osmosis plant and product water distribution system were repeatedly disinfected using 2% formalin and 1% bleach ensuring contact time and thorough rinsing to address persistent cultures. When these measures could not eradicate microbial growth, the system was sanitised with Gramicid (48% w/w H2O2 + 500 ppm Ag and all traces of the disinfectant were rinsed away before resuming haemodialysis. CONCLUSION The microbial contamination of dialysis water was eradicated by Gramicid and not by bleach or formalin without any adverse effects after thorough rinsing.

  9. Development of a biogas purifier for rural areas in Japan

    Kimura, Y.; Hinata, T. [Hokkaido Central Agricultural Experiment Station, Hokkaido (Japan); Yasui, S. [Zukosha Co. Ltd., Obihiro, Hokkaido (Japan); Noguchi, N. [Hokkaido Univ., Sapporo, Hokkaido (Japan); Tsukamoto, T. [IHI Shibaura. Co. Ltd., Obihiro, Hokkaido (Japan); Imai, T. [Green Plan Co. Ltd., Sapporo, Hokkaido (Japan); Kanai, M. [Air Water Co. Ltd, Sakai, Osaka (Japan); Matsuda, Z. [Hokuren Agricultural Research Center, Sapporo, Hokkaido (Japan)

    2010-07-01

    Although the biogas that is currently produced for dairy farms in Japan is a carbon-neutral energy, its use is restricted to farming areas only because there is no effective method of transporting unused biogas. There is a need for establishing practical methods for biogas removal from operating systems. In this study, a gas separation membrane was used in order to modify biogas to city gas 12A specifications, and to develop a biogas purifier equipped with a device to fill high pressure purified gas into cylinders to be taken outside the farming area. The objective was to expand the use of biogas produced from stand-alone gas plants. The amount of purified gas produced at a newly created refining-compression-filling (RCF) facility was approximately 97.0 Nm{sup 3}/day, for a raw material amount of about 216.0 Nm{sup 3}/day. The heat quantity of the purified gas was 38.9 MJ/Nm{sup 3}, which was within city gas 12A specifications. A total of 14.3 cylinders were filled each day with the manufactured purified gas. Test calculations along with a simulation exercise revealed that it would be possible to provide purified gas to approximately 6 per cent of common residences in a town in northern Japan. It was concluded that the newly created RCF facility allowed the modification of carbon-neutral biogas to conform to city gas 12A specifications, and allowed the transport of this gas out of the farming area.

  10. Planning for community resilience to future United States domestic water demand

    Costs of repairing and expanding aging infrastructure and competing demands for water from other sectors such as industry and agriculture are stretching water managers’ abilities to meet essential domestic drinking water needs for future generations. Using Bayesian statistical mo...

  11. Rechargeable biofilm-controlling tubing materials for use in dental unit water lines.

    Luo, Jie; Porteous, Nuala; Sun, Yuyu

    2011-08-01

    A simple and practical surface grafting approach was developed to introduce rechargeable N-halamine-based antimicrobial functionality onto the inner surfaces of continuous small-bore polyurethane (PU) dental unit waterline (DUWL) tubing. In this approach, tetrahydrofuran (THF) solution of a free-radical initiator, dicumyl peroxide (DCP), flowed through the PU tubing (inner diameter of 1/16 in., or 1.6 mm) to diffuse DCP into the tubing's inner walls, which was used as initiator in the subsequent grafting polymerization of methacrylamide (MAA) onto the tubing. Upon chlorine bleach treatment, the amide groups of the grafted MAA side chains were transformed into acyclic N-halamines. The reactions were confirmed with attenuated total reflectance infrared (ATR) spectra and iodometric titration. The mechanical properties of the tubing were not significantly affected by the grafting reactions. The biofilm-controlling function of the new N-halamine-based PU tubing was evaluated with Pseudomonas aeruginosa (P. aeruginosa), one of the most isolated water bacteria from DUWLs, in a continuous bacterial flow model. Bacteria culturing and SEM studies showed that the inner surfaces of the new N-halamine-based PU tubing completely prevented bacterial biofilm formation for at least three to four weeks. After that, bacteria began to colonize the tubing surface. However, the lost function was fully regenerated by exposing the tubing inner surfaces to diluted chlorine bleach. The recharging process could be repeated periodically to further extend the biofilm-controlling duration for long-term applications.

  12. A national reconnaissance for pharmaceuticals and other organic wastewater contaminants in the United States - II) Untreated drinking water sources

    Focazio, M.J.; Kolpin, D.W.; Barnes, K.K.; Furlong, E.T.; Meyer, M.T.; Zaugg, S.D.; Barber, L.B.; Thurman, M.E.

    2008-01-01

    Numerous studies have shown that a variety of manufactured and natural organic compounds such as pharmaceuticals, steroids, surfactants, flame retardants, fragrances, plasticizers and other chemicals often associated with wastewaters have been detected in the vicinity of municipal wastewater discharges and livestock agricultural facilities. To provide new data and insights about the environmental presence of some of these chemicals in untreated sources of drinking water in the United States targeted sites were sampled and analyzed for 100 analytes with sub-parts per billion detection capabilities. The sites included 25 ground- and 49 surface-water sources of drinking water serving populations ranging from one family to over 8 million people.

  13. Simulated water budget of a small forested watershed in the continental/maritime hydroclimatic region of the United States

    Liang Wei; Timothy E. Link; Andrew T. Hudak; John D. Marshall; Kathleen L. Kavanagh; John T. Abatzoglou; Hang Zhou; Robert E. Pangle; Gerald N. Flerchinger

    2016-01-01

    Annual streamflows have decreased across mountain watersheds in the Pacific Northwest of the United States over the last ~70 years; however, in some watersheds, observed annual flows have increased. Physically based models are useful tools to reveal the combined effects of climate and vegetation on long-term water balances by explicitly simulating the internal...

  14. 46 CFR 24.15-5 - Canadian pleasure craft temporarily using navigable waters of the United States.

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Canadian pleasure craft temporarily using navigable... SECURITY UNINSPECTED VESSELS GENERAL PROVISIONS Equivalents § 24.15-5 Canadian pleasure craft temporarily using navigable waters of the United States. Uninspected Canadian pleasure craft (uninspected vessels...

  15. INACTIVATION OF MS2 VIRUS IN DRINKING WATER: ATLANTIC ULTRAVIOLET CORPORATION MEGATRON UNIT, MODEL M250 AT CHULA VISTA, CALIFORNIA

    Verification testing of the Atlantic Ultraviolet Megatron M250 system was conducted over a 48-day period from 11/01/01 to 12/18/01. The feedwater to the ultraviolet (UV) unit during the testing was effluent from the Otay Water Treatment Plant (OWTP), a conventional plant with fl...

  16. Potential implications for expansion of freeze-tolerant eucalyptus plantations on water resources in the southern United States

    James M. Vose; Chelcy F. Miniat; Ge Sun; Peter V. Caldwell

    2014-01-01

    The potential expansion of freeze-tolerant (FT) Eucalyptus plantations in the United States has raised concerns about the implications for water resources. Modeling was used to examine the potential effects of expanding the distribution of FT Eucalyptus plantations in US Department of Agriculture Plant Hardiness Zones 8b and...

  17. Ground-Water Quality Data in the Middle Sacramento Valley Study Unit, 2006 - Results from the California GAMA Program

    Schmitt, Stephen J.; Fram, Miranda S.; Milby Dawson, Barbara J.; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 3,340 square mile Middle Sacramento Valley study unit (MSACV) was investigated from June through September, 2006, as part of the California Groundwater Ambient Monitoring and Assessment (GAMA) program. The GAMA Priority Basin Assessment project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Middle Sacramento Valley study was designed to provide a spatially unbiased assessment of raw ground-water quality within MSACV, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 108 wells in Butte, Colusa, Glenn, Sutter, Tehama, Yolo, and Yuba Counties. Seventy-one wells were selected using a randomized grid-based method to provide statistical representation of the study unit (grid wells), 15 wells were selected to evaluate changes in water chemistry along ground-water flow paths (flow-path wells), and 22 were shallow monitoring wells selected to assess the effects of rice agriculture, a major land use in the study unit, on ground-water chemistry (RICE wells). The ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], gasoline oxygenates and degradates, pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, and carbon-14, and stable isotopes of hydrogen, oxygen, nitrogen, and carbon), and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. Quality-control samples (blanks

  18. The Analysis of the System of special water purification of Beloyarskaya Nuclear Power Plant unit BN-800

    Valtseva, A. I.; Bibik, I. S.

    2017-11-01

    This article discusses how the latest system of special water purification KPF-30, designed specifically for the fourth power unit of Beloyarskaya nuclear power plant, which has a number of advantages over other water purification systems as chemical-physical and technical-economic, environmental, and other industrial indicators. The scheme covered in this article systems of special water purification involves the use of a hydrocyclone at the preliminary stage of water treatment, as a worthy alternative to ion-exchange filters, which can significantly reduce the volume of toxic waste. The world community implements the project of closing the nuclear fuel cycle, there is a need to improve the reliability of the equipment for safe processes and development of critical and supercritical parameters in the nuclear industry. Essentially, on operated NPP units, the only factor that can cost-effectively optimize to improve the reliability of equipment is the water chemistry. System KPF30 meets the principles and criteria of ecological safety, demonstrating the justification for reagent less method of water treatment on the main stages, in which no formation of toxic wastes, leading to irreversible consequences of environmental pollution and helps to conserve water.

  19. The fouling serpulids (Polychaeta: Serpulidae from United States coastal waters: an overview

    J. Rolando Bastida-Zavala

    2017-08-01

    minutus from Veracruz, Mexico to Pensacola Bay, Florida. The following additional species range extensions are provisional in that they represent only one record or were not found in the most recent surveys (e.g., Hydroides elegans - east coast: H. longispinosa from Marshall Islands to Oahu, Hawaii; Protula balboensis from Florida to Texas; P. longiseta from the Mexican Caribbean to the Indian River, Florida; H. elegans from San Francisco to Humboldt Bay, northern California and on the east coast from the Indian River, Florida, to Cape Cod, Massachusetts. Among surveyed bays, Biscayne Bay, Florida and Corpus Christi, Texas (northern Gulf of Mexico had the greatest number of species (14 and 8, respectively; in contrast, almost all sites in Alaska, Washington, Oregon (northwest Pacific, Rhode Island, Virginia and South Carolina (Atlantic had only one or two species each. Hydroides dianthus was, by far, the most abundant serpulid species on fouling plates in the northern Gulf of Mexico and the east coast, while Pseudochitinopoma occidentalis was the most abundant serpulid detected on the west coast. For each species recorded herein, we include the synonyms and some key references, a material studied section, a diagnosis, and updated distributional information. A checklist and identification key to the known shallow-water serpulids sensu stricto of the United States are included.

  20. Ground-Water Quality Data in the Coachella Valley Study Unit, 2007: Results from the California GAMA Program

    Goldrath, Dara A.; Wright, Michael T.; Belitz, Kenneth

    2009-01-01

    Ground-water quality in the approximately 820 square-mile Coachella Valley Study Unit (COA) was investigated during February and March 2007 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of raw ground water used for public-water supplies within the Coachella Valley, and to facilitate statistically consistent comparisons of ground-water quality throughout California. Samples were collected from 35 wells in Riverside County. Nineteen of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells). Sixteen additional wells were sampled to evaluate changes in water chemistry along selected ground-water flow paths, examine land use effects on ground-water quality, and to collect water-quality data in areas where little exists. These wells were referred to as 'understanding wells'. The ground-water samples were analyzed for a large number of organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicator compounds), constituents of special interest (perchlorate and 1,2,3-trichloropropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (uranium, tritium, carbon-14, and stable isotopes of hydrogen, oxygen, and boron), and dissolved noble gases (the last in collaboration with Lawrence Livermore National Laboratory) also were measured to help identify the source and age of the sampled

  1. Water Hammer Analysis using RELAP5/MOD 3.3 for Yonggwang Nuclear Power Unit 1 and 2 Blowdown System

    Lee, Sang Il; Kim, Hea Zoo; Chu, Jung Ho; Ahn, Se Hong; Jung, Chang Ho

    2010-01-01

    Water hammer can be defined as a rapid pressure step occurring in the liquid in a closed pipe caused by a sudden change in the liquid velocity. This pressure acts for a period which is twice the transit time of sonic wave in the pipe. Generally, water hammer can occur in any thermal-hydraulic systems like nuclear power plant and is extremely dangerous for nuclear power plant piping system since, if the pressure induced exceeds the pressure range of the pipe given by the manufacturer, it can lead to the failure of the piping system integrity. For Yonggwang nuclear power unit 1 and 2, water hammer occurred repeatedly on the outlet piping of regenerative heat exchanger of steam generator blowdown system. Thus, design modification was performed to prevent the water hammer and the analysis of effect on water hammer before and after design modification was performed to verify the validity of the design modification

  2. A Comparison of Different Disinfectants on the Microbiological Quality of Water from the Dental Unit Waterlines of a Military Hospital

    Ma, M.S.; Zalini Yunus; Ahmad Razi Mohamed Yunus; Zukri Ahmad; Farizah Abdul Fatah

    2015-01-01

    Water from the dental unit waterlines (DUWLs) is known to contaminate with microbial from the biofilm that formed in the tubing system. The water quality from DUWLs is important to patients and dental health care professionals as they could be infected either directly from the contaminated water or aerosol that is generated during dental procedures. Suppliers claimed that dental units supplied to the hospital can only use a specific disinfectant which is uneconomic compared with the others. The aims of this study were to evaluate and compare the efficacy of different disinfectant on the water quality of DUWLs. Four disinfectants (Calbenium, A-dec ICX tablet, Dentel 5, Metassys) and distil water were evaluated. 350 mL water sample was collected separately, from the outlet of high-speed hand piece, scaler, 3-ways syringe and cup filler into a sterile thiosulfate bag on the 1st, 2nd, 4th, 8th, 12th and 24th weeks of the study. The samples were tested on the following day for total viable count (TVC). There is significant difference in the efficacies of the different disinfectants. Only one disinfectant consistently produces water quality within the recommended level of American Dental Association (ADA). Within the limitation of this study, it was found that there is alternative disinfectant that can reduce the TVC to the level recommended by ADA. However, the water qualities produced with these disinfectants were not consistent although they did not cause any technical problem to the dental units during the period of study. (author)

  3. Geospatial data to support analysis of water-quality conditions in basin-fill aquifers in the southwestern United States

    McKinney, Tim S.; Anning, David W.

    2009-01-01

    The Southwest Principal Aquifers study area consists of most of California and Nevada and parts of Utah, Arizona, New Mexico, and Colorado; it is about 409,000 square miles. The Basin-fill aquifers extend through about 201,000 square miles of the study area and are the primary source of water for cities and agricultural communities in basins in the arid and semiarid southwestern United States (Southwest). The demand on limited ground-water resources in areas in the southwestern United States has increased significantly. This increased demand underscores the importance of understanding factors that affect the water quality in basin-fill aquifers in the region, which are being studied through the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) program. As a part of this study, spatial datasets of natural and anthropogenic factors that may affect ground-water quality of the basin-fill aquifers in the southwestern United States were developed. These data include physical characteristics of the region, such as geology, elevation, and precipitation, as well as anthropogenic factors, including population, land use, and water use. Spatial statistics for the alluvial basins in the Southwest have been calculated using the datasets. This information provides a foundation for the development of conceptual and statistical models that relate natural and anthropogenic factors to ground-water quality across the Southwest. A geographic information system (GIS) was used to determine and illustrate the spatial distribution of these basin-fill variables across the region. One hundred-meter resolution raster data layers that represent the spatial characteristics of the basins' boundaries, drainage areas, population densities, land use, and water use were developed for the entire Southwest.

  4. Epuration des eaux usées de raffinerie par le procédé biologique des lits bactériens. Problèmes pratiques de l'exploitation Purifying Refinery Waste Water by the Bacterial Bed Biological Process. Practical Operational Problems

    Leising M.

    2006-11-01

    filtration process is an interesting solution. Nonetheless, practical operating problems currently exist, and in particular the tendency for existing fixed film systems to become plugged up, resulting in the uncontrolled fouling of bulk liners. A study has shown that improper evacuation of the biomass are the cause of the problem. An investigation of how to control this phenomenon shows a distinction between curative and preventive measures. Curative measures consisting in regenerating the filter packing by increasing the hydraulic loading and by chemical or mechanical cleaning do not give full satisfaction. Among preventive measures, one method consists in reducing the organic loading of the effluent: phenol-containing waste waters are desalinated, waters from DGO and FCC are stripped, alcaline waters are reinjected into the crude oil, oils are recovered. just downstream from where they are discharged, and primary treatments are optimized, in particular by the installation of scrapers and oleophilic drums on the API separators and by a better choice of flocculants. Nevertheless, experience shows that this method does not delay plugging. The best method is in choosing contact medium, as is shown by comparative pilot-plant texts performed by Institut National de Recherche Chimique Appliquée (lRCHA and Compagnie Française de Raffinage (CFR. These tests were concentrated on the fate of the specific gravity of the packing on purifying performances and on sludge quality; they have showes that cloisonyle forming a tubular packing is probable the best suited material.

  5. Full scale demonstration of air-purifying pavement

    Ballari, M.; Brouwers, H.J.H.

    2013-01-01

    Experiments concerning a full-scale demonstration of air purifying pavement in Hengelo, The Netherlands, are reported. The full width of the street was provided with concrete pavement containing TiO2 over a length of 150 m ("DeNOx street"). Another part of the street, about 100 m, was paved with

  6. Air purification by cementitious materials: Evaluation of air purifying properties

    Hüsken, G.; Brouwers, H.J.H.; Al-Mattarneh, H.; Mustapha, K.N.; Nuruddin, M.F.

    2008-01-01

    This paper addresses the evaluation of the photocatalytic properties of concrete containing titanium dioxide (TiO2). Here, the assessment of the air purifying abilities of the hardened concrete regarding the degradation of nitric oxide (NO) is of major interest. A setup for measuring the performance

  7. Influence of a highly purified senna extract on colonic epithelium

    van Gorkom, B A; Karrenbeld, A; van Der Sluis, T; Koudstaal, J; de Vries, E G; Kleibeuker, J H

    2000-01-01

    BACKGROUND: Chronic use of sennoside laxatives often causes pseudomelanosis coli. A recent study suggested that pseudomelanosis coli is associated with an increased colorectal cancer risk. A single high dose of highly purified senna extract increased proliferation rate and reduced crypt length in

  8. Effect of partially purified angiotensin converting enzyme inhibitory ...

    This study evaluated the effect of partially-purified angiotensin converting enzyme (ACE) inhibitory proteins obtained from the leaves of Moringa oleifera on blood glucose, serum ACE activity and lipid profile of alloxaninduced diabetic rats. Twenty-five apparently healthy male albino rats were divided into five groups of five ...

  9. Air purification by cementitious materials : Evaluation of air purifying properties

    Hüsken, G.; Brouwers, H.J.H.; Al-Mattarneh, H.; Mustapha, K.N.; Nuruddin, M.F.

    2008-01-01

    This paper addresses the evaluation of the photocatalytic properties of concrete containing titanium dioxide (TiO2). Here, the assessment of the air purifying abilities of the hardened concrete regarding the degradation of nitric oxide (NO) is of major interest. A setup for measuring the performance

  10. 21 CFR 880.6500 - Medical ultraviolet air purifier.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical ultraviolet air purifier. 880.6500 Section 880.6500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... to ultraviolet radiation. (b) Classification. Class II (performance standards). ...

  11. Method of purifying phosphoric acid after solvent extraction

    Kouloheris, A.P.; Lefever, J.A.

    1979-01-01

    A method of purifying phosphoric acid after solvent extraction is described. The phosphoric acid is contacted with a sorbent which sorbs or takes up the residual amount of organic carrier and the phosphoric acid separated from the organic carrier-laden sorbent. The method is especially suitable for removing residual organic carrier from phosphoric acid after solvent extraction uranium recovery. (author)

  12. Mapping water availability, projected use and cost in the western United States

    Tidwell, Vincent C.; Moreland, Barbara D.; Zemlick, Katie M.; Roberts, Barry L.; Passell, Howard D.; Jensen, Daniel; Forsgren, Christopher; Sehlke, Gerald; Cook, Margaret A.; King, Carey W.; Larsen, Sara

    2014-05-01

    New demands for water can be satisfied through a variety of source options. In some basins surface and/or groundwater may be available through permitting with the state water management agency (termed unappropriated water), alternatively water might be purchased and transferred out of its current use to another (termed appropriated water), or non-traditional water sources can be captured and treated (e.g., wastewater). The relative availability and cost of each source are key factors in the development decision. Unfortunately, these measures are location dependent with no consistent or comparable set of data available for evaluating competing water sources. With the help of western water managers, water availability was mapped for over 1200 watersheds throughout the western US. Five water sources were individually examined, including unappropriated surface water, unappropriated groundwater, appropriated water, municipal wastewater and brackish groundwater. Also mapped was projected change in consumptive water use from 2010 to 2030. Associated costs to acquire, convey and treat the water, as necessary, for each of the five sources were estimated. These metrics were developed to support regional water planning and policy analysis with initial application to electric transmission planning in the western US.

  13. Retrospective Snow Analysis Across the Continental United States for the National Water Model

    Karsten, L. R.; Gochis, D.; Dugger, A. L.; McCreight, J. L.; Barlage, M. J.; Fall, G. M.; Olheiser, C.

    2016-12-01

    For large portions of the United States, snow plays a vital role in hydrologic prediction. This is particularly true in the mountain west where snowmelt contributes up to 80% of total streamflow runoff. The Office of Water Prediction (OWP) will begin running the National Water Model (NWM) during the second half of 2016, which is a continental-scale implementation of the WRF-Hydro community hydrologic modeling framework. Assessing and benchmarking the performance of the snow component of the NWM is important for future research-to-operations activities and for forecasters to better understand NWM output. For this study, WRF-Hydro was ran using the same domain and physics options as the NWM (1 km LSM, 250m overland routing, and NHDPlus Version 2.1 channel network). The land surface component chosen is Noah-MP land surface model. Forcing from the National Land Data Assimilation System (NLDAS-2) was downscaled from the native 0.125 degree resolution to the 1 km modeling domain to drive the model. The model was ran over a 5-year retrospective period to gauge multi-year performance of the snow states. Output was analyzed against both in-situ observations, such as SNOTEL, and the Snow Data Assimilation System (SNODAS). In addition, gridded snow states and SNODAS grids were aggregated to Omernik-derived ecological regions. This was done in order to break up snow analysis by regions that share similar ecological and physiographic characteristics. Results show WRF-Hydro is able to capture peak timing across most of the mountain west fairly well. In terms of magnitudes, the model struggles across portions of the west with a low bias. This is especially true in the Cascades, which could be traced back to precipitation partitioning issues in the model. Across the central Rockies, the model exhibits a lower dry bias showing improved performance there. Previous literature suggests a dry bias in the precipitation out west may be contributing to model performance. East of the

  14. Surface interactions between nanoscale iron and organic material: Potential uses in water treatment process units

    Storms, Max

    Membrane systems are among the primary emergent technologies in water treatment process units due to their ease of use, small physical footprint, and high physical rejection. Membrane fouling, the phenomena by which membranes become clogged or generally soiled, is an inhibitor to optimal efficiency in membrane systems. Novel, composite, and modified surface materials must be investigated to determine their efficacy in improving fouling behavior. Ceramic membranes derived from iron oxide nanoparticles called ferroxanes were coated with a superhydrophillic, zwitterionic polymer called poly (sulfobetaine methacrylate) (polySBMA) to form a composite ceramic-polymeric membrane. Membrane samples with and without polySBMA coating were subjected to fouling with a bovine serum albumin solution and fouling was observed by measuring permeate flux at 10 mL intervals. Loss of polySBMA was measured using total organic carbon analysis, and membrane samples were characterized using x-ray diffraction, scanning electron microscopy, and optical profilometry. The coated membrane samples decreased initial fouling rate by 27% and secondary fouling rate by 24%. Similarly, they displayed a 30% decrease in irreversible fouling during the initial fouling stage, and a 27% decrease in irreversible fouling in the secondary fouling stage; however, retention of polySBMA sufficient for improved performance was not conclusive. The addition of chemical disinfectants into drinking water treatment processes results in the formation of compounds called disinfection by-products (DBPs). The formation of DBPs occurs when common chemical disinfectants (i.e. chlorine) react with organic material. The harmful effects of DBP exposure require that they be monitored and controlled for public safety. This work investigated the ability of nanostructured hematite derived from ferroxane nanoparticles to remove organic precursors to DBPs in the form of humic acid via adsorption processes. The results show that p

  15. A Retrospective Analysis on the Occurrence of Arsenic in Ground-Water Resources of the United States and Limitations in Drinking-Water-Supply Characterizations

    Focazio, Michael J.; Welch, Alan H.; Watkins, Sharon A.; Helsel, Dennis R.; Horn, Marilee A.

    2000-01-01

    The Safe Drinking Water Act, as amended in 1996, requires the U.S. Environmental Protection Agency (USEPA) to review current drinking-water standards for arsenic, propose a maximum contaminant level for arsenic by January 1, 2000, and issue a final regulation by January, 2001. Quantification of the national occurrence of targeted ranges in arsenic concentration in ground water used for public drinking-water supplies is an important component of USEPA's regulatory process. Data from the U.S. Geological Survey (USGS) National Water Information System (NWIS) were used in a retrospective analysis of arsenic in the ground-water resources of the United States. The analysis augments other existing sources of data on the occurrence of arsenic collected in ground water at public water-supply systems.The USGS, through its District offices and national programs, has been compiling data for many years on arsenic concentrations collected from wells used for public water supply, research, agriculture, industry, and domestic water supply throughout the United States. These data have been collected for a variety of purposes ranging from simple descriptions of the occurrence of arsenic in local or regional ground-water resources to detailed studies on arsenic geochemistry associated with contamination sites. A total of 18,864 sample locations were selected from the USGS NWIS data base regardless of well type, of which 2,262 were taken from public water-supply sources. Samples with non-potable water (dissolved-solids concentration greater than 2,000 milligrams per liter and water temperature greater than 50o Celsius) were not selected for the retrospective analysis and other criteria for selection included the amount and type of ancillary data available for each sample. The 1,528 counties with sufficient data included 76 percent of all large public water-supply systems (serving more than 10,000 people) and 61 percent of all small public water-supply systems (serving more than 1

  16. Characterizing the Breadth and Depth of Volunteer Water Monitoring Programs in the United States

    Stepenuck, Kristine F.; Genskow, Kenneth D.

    2018-01-01

    A survey of 345 volunteer water monitoring programs in the United States was conducted to document their characteristics, and perceived level of support for data to inform natural resource management or policy decisions. The response rate of 86% provided information from 46 states. Programs represented a range of ages, budgets, objectives, scopes, and level of quality assurance, which influenced data uses and perceived support by sponsoring agency administrators and external decision makers. Most programs focused on rivers, streams, and lakes. Programs had not made substantial progress to develop EPA or state-approved quality assurance plans since 1998, with only 48% reporting such plans. Program coordinators reported feeling slightly more support for data to be used for management as compared to policy decisions. Programs with smaller budgets may be at particular risk of being perceived to lack credibility due to failure to develop quality assurance plans. Over half of programs identified as collaborative, in that volunteers assisted scientists in program design, data analysis and/or dissemination of results. Just under a third were contributory, in which volunteers primarily collected data in a scientist-defined program. Recommendations to improve perceived data credibility, and to augment limited budgets include developing quality assurance plans and gaining agency approval, and developing partnerships with other organizations conducting monitoring in the area to share resources and knowledge. Funding agencies should support development of quality assurance plans to help ensure data credibility. Service providers can aid in plan development by providing training to program staff over time to address high staff turnover rates.

  17. Sampling design and procedures for fixed surface-water sites in the Georgia-Florida coastal plain study unit, 1993

    Hatzell, H.H.; Oaksford, E.T.; Asbury, C.E.

    1995-01-01

    The implementation of design guidelines for the National Water-Quality Assessment (NAWQA) Program has resulted in the development of new sampling procedures and the modification of existing procedures commonly used in the Water Resources Division of the U.S. Geological Survey. The Georgia-Florida Coastal Plain (GAFL) study unit began the intensive data collection phase of the program in October 1992. This report documents the implementation of the NAWQA guidelines by describing the sampling design and procedures for collecting surface-water samples in the GAFL study unit in 1993. This documentation is provided for agencies that use water-quality data and for future study units that will be entering the intensive phase of data collection. The sampling design is intended to account for large- and small-scale spatial variations, and temporal variations in water quality for the study area. Nine fixed sites were selected in drainage basins of different sizes and different land-use characteristics located in different land-resource provinces. Each of the nine fixed sites was sampled regularly for a combination of six constituent groups composed of physical and chemical constituents: field measurements, major ions and metals, nutrients, organic carbon, pesticides, and suspended sediments. Some sites were also sampled during high-flow conditions and storm events. Discussion of the sampling procedure is divided into three phases: sample collection, sample splitting, and sample processing. A cone splitter was used to split water samples for the analysis of the sampling constituent groups except organic carbon from approximately nine liters of stream water collected at four fixed sites that were sampled intensively. An example of the sample splitting schemes designed to provide the sample volumes required for each sample constituent group is described in detail. Information about onsite sample processing has been organized into a flowchart that describes a pathway for each of

  18. Efforts to Reduce International Space Station Crew Maintenance for the Management of the Extravehicular Mobility Unit Transport Loop Water Quality

    Steele, John W.; Etter, David; Rector, Tony; Boyle, Robert; Vandezande, Christopher

    2013-01-01

    The EMU (Extravehicular Mobility Unit) contains a semi-closed-loop re-circulating water circuit (Transport Loop) to absorb heat into a LCVG (Liquid Coolant and Ventilation Garment) worn by the astronaut. A second, single-pass water circuit (Feed-water Loop) provides water to a cooling device (Sublimator) containing porous plates, and that water sublimates through the porous plates to space vacuum. The cooling effect from the sublimation of this water translates to a cooling of the LCVG water that circulates through the Sublimator. The quality of the EMU Transport Loop water is maintained through the use of a water processing kit (ALCLR Airlock Cooling Loop Remediation) that is used to periodically clean and disinfect the water circuit. Opportunities to reduce crew time associated with on-orbit ALCLR operations include a detailed review of the historical water quality data for evidence to support an extension to the implementation cycle. Furthermore, an EMU returned after 2-years of use on the ISS (International Space Station) is being used as a test bed to evaluate the results of extended and repeated ALCLR implementation cycles. Finally, design, use and on-orbit location enhancements to the ALCLR kit components are being considered to allow the implementation cycle to occur in parallel with other EMU maintenance and check-out activities, and to extend the life of the ALCLR kit components. These efforts are undertaken to reduce the crew-time and logistics burdens for the EMU, while ensuring the long-term health of the EMU water circuits for a post-Shuttle 6-year service life.

  19. Development of Water Quality Forecasting Models Based on the SOM-ANN on TMDL Unit Watershed in Nakdong River

    KIM, M.; Kim, J.; Baek, J.; Kim, C.; Shin, H.

    2013-12-01

    It has being happened as flush flood or red/green tide in various natural phenomena due to climate change and indiscreet development of river or land. Especially, water being very important to man should be protected and managed from water quality pollution, and in water resources management, real-time watershed monitoring system is being operated with the purpose of keeping watch and managing on rivers. It is especially important to monitor and forecast water quality in watershed. A study area selected Nak_K as one site among TMDL unit watershed in Nakdong River. This study is to develop a water quality forecasting model connected with making full use of observed data of 8 day interval from Nakdong River Environment Research Center. When forecasting models for each of the BOD, DO, COD, and chlorophyll-a are established considering correlation of various water quality factors, it is needed to select water quality factors showing highly considerable correlation with each water quality factor which is BOD, DO, COD, and chlorophyll-a. For analyzing the correlation of the factors (reservoir discharge, precipitation, air temperature, DO, BOD, COD, Tw, TN, TP, chlorophyll-a), in this study, self-organizing map was used and cross correlation analysis method was also used for comparing results drawn. Based on the results, each forecasting model for BOD, DO, COD, and chlorophyll-a was developed during the short period as 8, 16, 24, 32 days at 8 day interval. The each forecasting model is based on neural network with back propagation algorithm. That is, the study is connected with self-organizing map for analyzing correlation among various factors and neural network model for forecasting of water quality. It is considerably effective to manage the water quality in plenty of rivers, then, it specially is possible to monitor a variety of accidents in water quality. It will work well to protect water quality and to prevent destruction of the environment becoming more and more

  20. Methods for estimating water consumption for thermoelectric power plants in the United States

    Diehl, Timothy H.; Harris, Melissa; Murphy, Jennifer C.; Hutson, Susan S.; Ladd, David E.

    2013-01-01

    Water consumption at thermoelectric power plants represents a small but substantial share of total water consumption in the U.S. However, currently available thermoelectric water consumption data are inconsistent and incomplete, and coefficients used to estimate consumption are contradictory. The U.S. Geological Survey (USGS) has resumed the estimation of thermoelectric water consumption, last done in 1995, based on the use of linked heat and water budgets to complement reported water consumption. This report presents the methods used to estimate freshwater consumption at a study set of 1,284 power plants based on 2010 plant characteristics and operations data.

  1. Pre-commissioning activities of exchange units of Heavy Water Plant, Manuguru (Paper No. 1.2)

    Kamath, H.S.; Sikaria, R.P.

    1992-01-01

    Heavy Water Plant, Manuguru (HWPM) comprises of two exchange units where enrichment of deuterium from natural concentration to 15% concentration is achieved using dual temperature H 2 S-H 2 O exchange process in a three stage cascade. In each exchange unit an inventory of around 200 MT of H 2 S gas is required under normal operating pressure and a feed water flow rate of 450 MT/Hr is required to be maintained. In view of the large flow rates of H 2 S circulating gas, water, cooling water, steam etc., the lines sizes in exchange unit are quite large. Further, H 2 S gas being highly toxic and corrosive, extreme care is required in order to ensure integrity and leak tightness. While due care is taken in material selection, design, quality surveillance etc., during fabrication, certain additional measures are required to be taken during precommissioning of the systems handling H 2 S under pressure. This paper deals with the activities from completion of plant erection including hydrotesting of piping by the piping contractor to the stage of trial production run. (author)

  2. A PERFORMANCE MODELING AND DECISION SUPPORT SYSTEM FOR A FEED WATER UNIT OF A THERMAL POWER PLANT

    S. Gupta

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: The present paper discusses the performance modeling and decision support system for a feed water unit of a thermal power plant using the concept of performance analysis and modeling. A feed water unit ensures a proper supply of water for the sound functioning of a thermal power plant. The decision support system for a feed water unit has been developed with the help of performance modeling using a probabilistic approach. After drawing a transition diagram, differential equations are generated. After that, steady state probabilities are determined. Some decision matrices are also developed, which provide various performance levels for different combinations of failure and repair rates of all subsystems. Based upon various availability values obtained in decision matrices and plots of failure rates / repair rates of various subsystems, the performance of each subsystem is analyzed, and maintenance decisions are made for all subsystems.

    AFRIKAANSE OPSOMMING: Vertoningsanalise en –modellering word gedoen vir die toevoerwatersisteem van ‘n termiese kragstasie. Toevoerwater is ‘n belangrike factor vir die doeltreffende bedryf van ‘n kragstasie. Die vertoningsanalise en –model is probalisties van aard. ‘n Toestandoorgangsdiagram en bypassende differensiaalvergelykings word gebruik, gevolg deur bepaling van die bestandige sisteemtoestand. Bykomende aandag word gegee aan relevante subsisteme. Die vertoning van subsisteme word gebasseer op verskeie beskikbaarheidswaardes om sodoende instandhouding to optimiseer.

  3. The water implications of generating electricity: water use across the United States based on different electricity pathways through 2050

    Macknick, J; Sattler, S; Clemmer, S; Rogers, J; Averyt, K

    2012-01-01

    The power sector withdraws more freshwater annually than any other sector in the US. The current portfolio of electricity generating technologies in the US has highly regionalized and technology-specific requirements for water. Water availability differs widely throughout the nation. As a result, assessments of water impacts from the power sector must have a high geographic resolution and consider regional, basin-level differences. The US electricity portfolio is expected to evolve in coming years, shaped by various policy and economic drivers on the international, national and regional level; that evolution will impact power sector water demands. Analysis of future electricity scenarios that incorporate technology options and constraints can provide useful insights about water impacts related to changes to the technology mix. Utilizing outputs from the regional energy deployment system (ReEDS) model, a national electricity sector capacity expansion model with high geographical resolution, we explore potential changes in water use by the US electric sector over the next four decades under various low carbon energy scenarios, nationally and regionally. (letter)

  4. EnviroAtlas - Domestic Water Demand by 12-Digit HUC for the Conterminous United States

    U.S. Environmental Protection Agency — This EnviroAtlas dataset includes domestic water demand attributes which provide insight into the amount of water currently used for indoor and outdoor residential...

  5. Water: Essential Element of United States Security Policy in the Middle East

    Larson, Lars E

    1991-01-01

    .... Traditional sources of water have been taxed by the growth of populations in the area and their accompanying problems of pollution, waste, improper operation of water facilities, and poor cooperation...

  6. EnviroAtlas - Industrial Water Demand (2010) by 12-Digit HUC for the Conterminous United States

    U.S. Environmental Protection Agency — This EnviroAtlas dataset includes industrial water demand attributes which provide insight into the amount of water currently used for manufacturing and production...

  7. Economics of residential gas furnaces and water heaters in United States new construction market

    Lekov, Alex B.

    2009-01-01

    New single-family home construction represents a significant and important market for the introduction of energy-efficient gas-fired space heating and water-heating equipment. In the new construction market, the choice of furnace and water-heater type is primarily driven by first cost considerations and the availability of power vent and condensing water heaters. Few analysis have been performed to assess the economic impacts of the different combinations of space and water-heating equipment....

  8. Implications of Upstream Flow Availability for Watershed Surface Water Supply Across the Conterminous United States

    Kai Duan; Ge Sun; Peter V. Caldwell; Steven G. McNulty; Yang Zhang

    2018-01-01

    Although it is well established that the availability of upstream flow (AUF) affects downstream water supply, its significance has not been rigorously categorized and quantified at fine resolutions. This study aims to fill this gap by providing a nationwide inventory of AUF and local water resource, and assessing their roles in securing water supply across the 2,099 8-...

  9. Auto Drain Valve Water Separator inside the Unit of Komatsu HD 465-7R

    Manurung, V. A. T.; Joko W, Y. T.; Poetra, R. I.

    2018-02-01

    Water separator is a component that separate water from fuel, so the circulating fuel in the fuel system is not contaminated by water. If there is water inside the water separator, it will be carried by into the fuel system and then impacting to the engine performance. It’s such as lowering engine power because the fuel filter is clogged due to the fuel mix with water. Then the real danger is in case of the fuel mixes with the water. It will damage the fuel system components such as blockage of injectors due to corrosion and wear of fuel supply pump. As informed from daily maintenance record data, we have found that the low power engine trouble was caused by the fuel filter that was clogged high enough. Using the fishbone analysis, we got the main problem is there was water in the fuel separator at maximum level and did not discharge. In this condition, it is need optional device to automatically discharge the water from the water separator while maximum level reached, so the operator does not need to drain the water manually. The operator will be warned by buzzing active alarm and flashing caution lamp inside the cabin. By this method, the potential risk of mix up water with fuel would be avoided and the loss of others component failure would be mostly avoided. By using this tool, we can save net quality income around IDR (Indonesia Rupiah) 11,673,519,800.

  10. Water stress projections for the northeastern and Midwestern United States in 2060: anthropogenic and ecological consequences

    Brian G. Tavernia; Mark D. Nelson; Peter Caldwell; Ge Sun

    2013-01-01

    Future climate and land-use changes and growing human populations may reduce the abundance of water resources relative to anthropogenic and ecological needs in the Northeast and Midwest (U.S.). We used output from WaSSI, a water accounting model, to assess potential changes between 2010 and 2060 in (1) anthropogenic water stress for watersheds throughout the Northeast...

  11. Management of the Post-Shuttle Extravehicular Mobility Unit (EMU) Water Circuits

    Steele, John W.; Etter, David; Rector, Tony; Hill, Terry; Wells, Kevin

    2011-01-01

    The EMU incorporates two separate water circuits for the rejection of metabolic heat from the astronaut and the cooling of electrical components. The first (the Transport Water Loop) circulates in a semi-closed-loop manner and absorbs heat into a Liquid Coolant and Ventilation Garment (LCVG) warn by the astronaut. The second (the Feed Water Loop) provides water to a cooling device (Sublimator) with a porous plate, and that water subsequently sublimates to space vacuum. The cooling effect from the sublimation of this water translates to a cooling of the LCVG water that circulates through the Sublimator. Efforts are underway to streamline the use of a water processing kit (ALCLR) that is being used to periodically clean and disinfect the Transport Loop Water. Those efforts include a fine tuning of the duty cycle based on a review of prior performance data as well as an assessment of a fixed installation of this kit into the EMU backpack or within on-orbit EMU interface hardware. Furthermore, testing is being conducted to ensure compatibility between the International Space Station (ISS) Water Processor Assembly (WPA) effluent and the EMU Sublimator as a prelude to using the WPA effluent as influent to the EMU Feed Water loop. This work is undertaken to reduce the crew-time and logistics burdens for the EMU, while ensuring the long-term health of the EMU water circuits for a post-Shuttle 6-year service life.

  12. Potential interactions among disease, pesticides, water quality and adjacent land cover in amphibian habitats in the United States

    Battaglin, William A.; Smalling, Kelly L.; Anderson, Chauncey; Calhoun, Daniel L.; Chestnut, Tara E.; Muths, Erin L.

    2016-01-01

    To investigate interactions among disease, pesticides, water quality, and adjacent land cover, we collected samples of water, sediment, and frog tissue from 21 sites in 7 States in the United States (US) representing a variety of amphibian habitats. All samples were analyzed for > 90 pesticides and pesticide degradates, and water and frogs were screened for the amphibian chytrid fungus Batrachochytrium dendrobatidis (Bd) using molecular methods. Pesticides and pesticide degradates were detected frequently in frog breeding habitats (water and sediment) as well as in frog tissue. Fungicides occurred more frequently in water, sediment, and tissue than was expected based upon their limited use relative to herbicides or insecticides. Pesticide occurrence in water or sediment was not a strong predictor of occurrence in tissue, but pesticide concentrations in tissue were correlated positively to agricultural and urban land, and negatively to forested land in 2-km buffers around the sites. Bd was detected in water at 45% of sites, and on 34% of swabbed frogs. Bd detections in water were not associated with differences in land use around sites, but sites with detections had colder water. Frogs that tested positive for Bd were associated with sites that had higher total fungicide concentrations in water and sediment, but lower insecticide concentrations in sediments relative to frogs that were Bd negative. Bd concentrations on frog swabs were positively correlated to dissolved organic carbon, and total nitrogen and phosphorus, and negatively correlated to pH and water temperature.Data were collected from a range of locations and amphibian habitats and represent some of the first field-collected information aimed at understanding the interactions between pesticides, land use, and amphibian disease. These interactions are of particular interest to conservation efforts as many amphibians live in altered habitats and may depend on wetlands embedded in these landscapes to

  13. Potential interactions among disease, pesticides, water quality and adjacent land cover in amphibian habitats in the United States.

    Battaglin, W A; Smalling, K L; Anderson, C; Calhoun, D; Chestnut, T; Muths, E

    2016-10-01

    To investigate interactions among disease, pesticides, water quality, and adjacent land cover, we collected samples of water, sediment, and frog tissue from 21 sites in 7 States in the United States (US) representing a variety of amphibian habitats. All samples were analyzed for >90 pesticides and pesticide degradates, and water and frogs were screened for the amphibian chytrid fungus Batrachochytrium dendrobatidis (Bd) using molecular methods. Pesticides and pesticide degradates were detected frequently in frog breeding habitats (water and sediment) as well as in frog tissue. Fungicides occurred more frequently in water, sediment, and tissue than was expected based upon their limited use relative to herbicides or insecticides. Pesticide occurrence in water or sediment was not a strong predictor of occurrence in tissue, but pesticide concentrations in tissue were correlated positively to agricultural and urban land, and negatively to forested land in 2-km buffers around the sites. Bd was detected in water at 45% of sites, and on 34% of swabbed frogs. Bd detections in water were not associated with differences in land use around sites, but sites with detections had colder water. Frogs that tested positive for Bd were associated with sites that had higher total fungicide concentrations in water and sediment, but lower insecticide concentrations in sediments relative to frogs that were Bd negative. Bd concentrations on frog swabs were positively correlated to dissolved organic carbon, and total nitrogen and phosphorus, and negatively correlated to pH and water temperature. Data were collected from a range of locations and amphibian habitats and represent some of the first field-collected information aimed at understanding the interactions between pesticides, land use, and amphibian disease. These interactions are of particular interest to conservation efforts as many amphibians live in altered habitats and may depend on wetlands embedded in these landscapes to survive

  14. Potential Effectiveness of Point-of-Use Filtration to Address Risks to Drinking Water in the United States.

    Brown, Kathleen Ward; Gessesse, Bemnet; Butler, Lindsey J; MacIntosh, David L

    2017-01-01

    Numerous contemporary incidents demonstrate that conventional control strategies for municipal tap water have limited ability to mitigate exposures to chemicals whose sources are within distribution systems, such as lead, and chemicals that are not removed by standard treatment technologies, such as perfluorooctanoic acid (PFOA)/perfluorooctanesulfonic acid (PFOS). In these situations, point-of-use (POU) controls may be effective in mitigating exposures and managing health risks of chemicals in drinking water, but their potential utility has not been extensively examined. As an initial effort to fill this information gap, we conducted a critical review and analysis of the existing literature and data on the effectiveness of POU drinking water treatment technologies for reducing chemical contaminants commonly found in tap water in the United States. We found that many types of water treatment devices available to consumers in the United States have undergone laboratory testing and often certification for removal of chemical contaminants in tap water, but in most cases their efficacy in actual use has yet to be well characterized. In addition, the few studies of POU devices while "in use" focus on traditional contaminants regulated under the Safe Drinking Water Act, but do not generally consider nontraditional contaminants of concern, such as certain novel human carcinogens, industrial chemicals, pesticides, pharmaceuticals, personal care products, and flame retardants. Nevertheless, the limited information available at present suggests that POU devices can be highly effective when used prophylactically and when deployed in response to contamination incidents. Based on these findings, we identify future areas of research for assessing the ability of POU filters to reduce health-related chemical contaminants distributed through public water systems and private wells.

  15. Polymorphism in the Mr 32,000 Rh protein purified from Rh(D)-positive and -negative erythrocytes

    Saboori, A.M.; Smith, B.L.; Agre, P.

    1988-01-01

    A M r 32,000 integral membrane protein has previously been identified on erythrocytes bearing the Rh(D) antigen and is thought to contain the antigenic variations responsible for the different Rh phenotypes. To study it on a biochemical level, a simple large-scale method was developed to purify the M r 32,000 Rh protein from multiple units of Rh(D)-positive and -negative blood. Erythrocyte membrane vesicles were solubilized in NaDodSO 4 , and a tracer of immunoprecipitated 125 I surface-labeled Rh protein was added. The Rh protein was purified to homogeneity by hydroxylapatite chromatography followed by preparative NaDodSO 4 /PAGE. Approximately 25 nmol of pure Rh protein was recovered from each unit of Rh(D)-positive and -negative blood. Rh protein purified from both Rh phenotypes appeared similar by one-dimensional NaDodSO 4 /PAGE, and the N-terminal amino acid sequences for the first 20 residues were identical. Rh proteins purified from Rh(D)-positive and -negative blood were compared by two-dimensional iodopeptide mapping after 125 I-labeling and α-chymotrypsin digestion. The peptide maps were very similar. These data indicate that a similar core Rh protein exists in both Rh(D)-positive and -negative erythrocytes, and the Rh proteins from erythrocytes with different Rh phenotypes contain distinct structural polymorphisms

  16. Increased water contamination and grow-out Pekin duck mortality when raised with water troughs compared to pin-metered water lines using a United States management system

    Schenk, A.; Porter, A. L.; Alenciks, E.; Frazier, K.; Best, A. A.; Fraley, S. M.; Fraley, G. S.

    2016-01-01

    Controversy has developed as to whether or not pin-metered water lines or water troughs are more appropriate for Pekin ducks. We hypothesized that water troughs would show improved duck body conditions and environmental quality compared to pin-metered water lines. To test this hypothesis, we housed ducks in 2 barns, one with water lines and one with water troughs. Water troughs were constructed to meet RSPCA guidelines for number and density of ducks and with recently described verandas. Ducks were divided into 4 pens per barn (n = 1,000 ducks/pen). The study was then repeated (n = 8 pens per water source) in a cross-over design so the barns each contained the opposite water source to the first experiment. We scored the ducks’ body condition using an established scoring rubric and analyzed using SAS Proc GLM-Mix as binomial data. Ducks housed with water troughs showed higher (thus worse condition; P duck mortality using a Student t test for both water sources each week. We found that the water troughs showed higher iron (P Ducks housed with water troughs used greater (P = 0.001) volumes of water compared to ducks housed with water lines. Ducks with water troughs also showed a greater percent (P = 0.008) mortality at all ages compared to ducks with water lines. These data suggest that water troughs may not be beneficial for duck welfare and could adversely impact both environment and duck or human health. PMID:26769272

  17. Pharmaceuticals in the Built and Natural Water Environment of the United States

    Randhir P. Deo

    2013-09-01

    Full Text Available The known occurrence of pharmaceuticals in the built and natural water environment, including in drinking water supplies, continues to raise concerns over inadvertent exposures and associated potential health risks in humans and aquatic organisms. At the same time, the number and concentrations of new and existing pharmaceuticals in the water environment are destined to increase further in the future as a result of increased consumption of pharmaceuticals by a growing and aging population and ongoing measures to decrease per-capita water consumption. This review examines the occurrence and movement of pharmaceuticals in the built and natural water environment, with special emphasis on contamination of the drinking water supply, and opportunities for sustainable pollution control. We surveyed peer-reviewed publications dealing with quantitative measurements of pharmaceuticals in U.S. drinking water, surface water, groundwater, raw and treated wastewater as well as municipal biosolids. Pharmaceuticals have been observed to reenter the built water environment contained in raw drinking water, and they remain detectable in finished drinking water at concentrations in the ng/L to μg/L range. The greatest promises for minimizing pharmaceutical contamination include source control (for example, inputs from intentional flushing of medications for safe disposal, and sewer overflows, and improving efficiency of treatment facilities.

  18. Water use and supply concerns for utility-scale solar projects in the Southwestern United States.

    Klise, Geoffrey Taylor; Tidwell, Vincent Carroll; Reno, Marissa Devan; Moreland, Barbara Denise.; Zemlick, Katie M.; Macknick, Jordan

    2013-07-01

    As large utility-scale solar photovoltaic (PV) and concentrating solar power (CSP) facilities are currently being built and planned for locations in the U.S. with the greatest solar resource potential, an understanding of water use for construction and operations is needed as siting tends to target locations with low natural rainfall and where most existing freshwater is already appropriated. Using methods outlined by the Bureau of Land Management (BLM) to determine water used in designated solar energy zones (SEZs) for construction and operations & maintenance, an estimate of water used over the lifetime at the solar power plant is determined and applied to each watershed in six Southwestern states. Results indicate that that PV systems overall use little water, though construction usage is high compared to O&M water use over the lifetime of the facility. Also noted is a transition being made from wet cooled to dry cooled CSP facilities that will significantly reduce operational water use at these facilities. Using these water use factors, estimates of future water demand for current and planned solar development was made. In efforts to determine where water could be a limiting factor in solar energy development, water availability, cost, and projected future competing demands were mapped for the six Southwestern states. Ten watersheds, 9 in California, and one in New Mexico were identified as being of particular concern because of limited water availability.

  19. Upgrading of Alum Preparation and Dosing Unit for Sharq Dijla Water Treatment Plant by Using Programmable Logic Controller System

    Aumar Al-Nakeeb

    2018-02-01

    Full Text Available One of the important units in Sharq Dijla Water Treatment Plant (WTP first and second extensions are the alum solution preparation and dosing unit. The existing operation of this unit accomplished manually starting from unloading the powder alum in the preparation basin and ending by controlling the alum dosage addition through the dosing pumps to the flash mix chambers. Because of the modern trend of monitoring and control the automatic operation of WTPs due to the great benefits that could be gain from optimum equipment operation, reducing the operating costs and human errors. This study deals with how to transform the conventional operation to an automatic monitoring and controlling system depending on a Programmable Logic Controller (PLC and online sensors for alum preparation and dosing unit in Sharq Dijla WTP. PLC system will receive, analyze transmitting data, compare them with preset points then automatically orders the operational equipment (such as pumps, valves, and mixers in a way that guarantees the safe and appropriate operation of the unit. As a result of Process and Instrumentation Diagrams (PID that were prepared in this study, these units can be fully operating and manage by using Supervisory Control and Data Acquisition (SCADA system.

  20. Traveling Uncharted Waters: The Exchange of Government Information between the United States and China.

    Wang, Rui

    1998-01-01

    Describes a program established between the United States and China for exchange of government publications through their national libraries, the Library of Congress and the National Library of China. Challenges to the program, including the shift to electronic formats in the United States and government Internet censorship in China, are…

  1. Bridging the Gap: Ideas for water sustainability in the western United States

    Tidwell, V. C.; Passell, H. D.; Roach, J. D.

    2012-12-01

    Incremental improvements in water sustainability in the western U.S. may not be able to close the growing gap between increasing freshwater demand, climate driven variability in freshwater supply, and growing environmental consciousness. Incremental improvements include municipal conservation, improvements to irrigation technologies, desalination, water leasing, and others. These measures, as manifest today in the western U.S., are successful in themselves but limited in their ability to solve long term water scarcity issues. Examples are plainly evident and range from the steady and long term decline of important aquifers and their projected inability to provide water for future agricultural irrigation, projected declines in states' abilities to meet legal water delivery obligations between states, projected shortages of water for energy production, and others. In many cases, measures that can close the water scarcity gap have been identified, but often these solutions simply shift the gap from water to some other sector, e.g., economics. Saline, brackish or produced water purification, for example, could help solve western water shortages in some areas, but will be extremely expensive, and so shift the gap from water to economics. Transfers of water out of agriculture could help close the water scarcity gap in other areas; however, loss of agriculture will shift the gap to regional food security. All these gaps, whether in water, economics, food security, or other sectors, will have a negative impact on the western states. Narrowing these future gaps requires both technical and policy solutions as well as tools to understand the tradeoffs. Here we discuss several examples from across the western U.S. that span differing scales and decision spaces. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear

  2. Ground-Water Quality Data in the Coastal Los Angeles Basin Study Unit, 2006: Results from the California GAMA Program

    Mathany, Timothy M.; Land, Michael; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 860 square-mile Coastal Los Angeles Basin study unit (CLAB) was investigated from June to November of 2006 as part of the Statewide Basin Assessment Project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Statewide Basin Assessment was developed in response to the Ground-Water Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Coastal Los Angeles Basin study was designed to provide a spatially unbiased assessment of raw ground-water quality within CLAB, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 69 wells in Los Angeles and Orange Counties. Fifty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (?grid wells?). Fourteen additional wells were selected to evaluate changes in ground-water chemistry or to gain a greater understanding of the ground-water quality within a specific portion of the Coastal Los Angeles Basin study unit ('understanding wells'). Ground-water samples were analyzed for: a large number of synthetic organic constituents [volatile organic compounds (VOCs), gasoline oxygenates and their degradates, pesticides, polar pesticides, and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicators]; constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), 1,4-dioxane, and 1,2,3-trichloropropane (1,2,3-TCP)]; inorganic constituents that can occur naturally [nutrients, major and minor ions, and trace elements]; radioactive constituents [gross-alpha and gross-beta radiation, radium isotopes, and radon-222]; and microbial indicators. Naturally occurring isotopes [stable isotopic ratios of hydrogen and oxygen, and activities of tritium and carbon-14

  3. Geological Factors Affecting Flow Spatial Continuity in Water Injection of Units Operating in the LGITJ–0102 Ore Body

    Ilver M. Soto-Loaiza

    2016-05-01

    Full Text Available The objective of the investigation was to identify the geological factors affecting the spatial continuity of the flow during the process of flank water injection in the units operating in the Lower Lagunilla Hydrocarbon Ore Body. This included the evaluation of the recovery factor, the petro-physic properties such as porosity, permeability, water saturation and rock type and quality in each flow unit. it was observed that the rock type of the geologic structure in the ore body is variable. The lowest values for the petro-physic properties were found in the southern area while a high variability of these parameters was observed in the northern and central areas. It was concluded that the northern area has a great potential for the development of new injection projects for petroleum recovery.

  4. Synthesis and characterization of highly purified nanosilica from pyrophyllite ores

    Fuad, Abdulloh, E-mail: abdulloh.fuad.fmipa@um.ac.id; Mufti, Nandang; Diantoro, Markus; Subakti,; Septa Kurniawati, S. [Jurusan Fisika FMIPA Universitas Negeri Malang. Jl. Semarang No. 5 Malang, east Java (Indonesia)

    2016-03-11

    A simple method based on alkaline extraction followed by acid precipitation and acid dissolution has been developed to produce highly purified nanosilica from pyrophyllite materials. The reaction parameters such as molar ratio NaOH/SiO{sub 2}, reaction time and reaction temperature are varied for obtaining maximum nanosilica convertion. About 99,45% highly purified precipitated nanosilica measure with ICP, 259 m{sup 2}/gr measure with BET surface area, 97% whiteness and 3 ml/gr oil absorbtion from pyrophyllite materials has been achieved in closed system at 150°C within 180 min. The physicals and chemical properties (such as X-Ray Diffraction from PANalytical, X-Ray Fluorescence Minipal4 from PANanalytical, BET surface area, Forier Transform Infra Red Spectroscopy from Hitachi, and SEM-EDS Inspect-S50 from FEI Company) of the highly purity nanosilica were studied.

  5. Ultrasonic-resonator-combined apparatus for purifying nuclear aerosol particles

    Hou, Suxia; Zhang, Quanhu; Li, Sufen; Chen, Chen; Su, Xianghua [Xi' an Hi-Tech Institute, Xi' an (China)

    2017-12-15

    The radiation hazards of radionuclides in the air arising from the storage room of nuclear devices to the operators cannot be ignored. A new ultrasonic-resonator-combined method for purifying nuclear aerosol particles is introduced. To remove particles with diameters smaller than 0.3 μm, an ultrasonic chamber is induced to agglomerate these submicron particles. An apparatus which is used to purify the nuclear aerosol particles is described in the article. The apparatus consists of four main parts: two filtering systems, an ultrasonic chamber and a high-pressure electrostatic precipitator system. Finally, experimental results demonstrated the effectiveness of the implementation of the ultrasonic resonators. The feasibility of the method is proven by its application to the data analysis of the experiments.

  6. Occurrence of Conjugated Linolenic Acids in Purified Soybean Oil

    Kinami, Tomohisa; Horii, Naoto; Narayan, Bhaskar; Arato, Shingo; Hosokawa, Masashi; Miyashita, Kazuo; Negishi, Hironori; Ikuina, Junichi; Noda, Ryuji; Shirasawa, Seiichi

    2007-01-01

    A high-performance liquid chromatographic (HPLC) method is described for the determination of conjugated linoleic acids (CLA) and conjugated linolenic acids (CLN). Methyl esters prepared from purified lipid fractions of soybean oil were analyzed using an HPLC system equipped with photodiode-array detector to detect peaks having maximum absorption around 233 and 275 nm. These peaks were concentrated by AgNO3-silicic acid column chromatography and reversed-phase HPLC. The structural analysis, o...

  7. Risk of waterborne illness via drinking water in the United States.

    Reynolds, Kelly A; Mena, Kristina D; Gerba, Charles P

    2008-01-01

    Outbreaks of disease attributable to drinking water are not common in the U.S., but they do still occur and can lead to serious acute, chronic, or sometimes fatal health consequences, particularly in sensitive and immunocompromised populations. From 1971 to 2002, there were 764 documented waterborne outbreaks associated with drinking water, resulting in 575,457 cases of illness and 79 deaths (Blackburn et al. 2004; Calderon 2004); however, the true impact of disease is estimated to be much higher. If properly applied, current protocols in municipal water treatment are effective at eliminating pathogens from water. However, inadequate, interrupted, or intermittent treatment has repeatedly been associated with waterborne disease outbreaks. Contamination is not evenly distributed but rather affected by the number of pathogens in the source water, the age of the distribution system, the quality of the delivered water, and climatic events that can tax treatment plant operations. Private water supplies are not regulated by the USEPA and are generally not treated or monitored, although very few of the municipal systems involved in documented outbreaks exceeded the USEPA's total coliform standard in the preceding 12 mon (Craun et al. 2002). We provide here estimates of waterborne infection and illness risks in the U.S. based on the total number of water systems, source water type, and total populations exposed. Furthermore, we evaluated all possible illnesses associated with the microbial infection and not just gastroenteritis. Our results indicate that 10.7 M infections/yr and 5.4 M illnesses/yr occur in populations served by community groundwater systems; 2.2 M infections/yr and 1.1 M illnesses/yr occur in noncommunity groundwater systems; and 26.0 M infections/yr and 13.0 M illnesses/yr occur in municipal surface water systems. The total estimated number of waterborne illnesses/yr in the U.S. is therefore estimated to be 19.5 M/yr. Others have recently estimated

  8. Effect of Amphiphilic Alkyl Chain Length Upon Purified LATEX Stability

    Amira Amir Hassan; Amir Hashim Mohd Yatim

    2015-01-01

    Rubber particles in purified latex (PL) are stabilized by a film of protein and fatty acid soap (surfactant). Saturated straight-chain fatty acid soaps can assist an enhancement of latex stability. However, whether the alkyl chain length plays an important role in increasing the stability is still an issue. The aim of this study is to investigate the effect of alkyl chain length of anionic surfactant on the stability of purified latex. The fatty acid soap of decanoate (9), laurate (11), sodium dodecyl sulphate (SDS) (12) and palmitate (15) were used. The numbers in parentheses indicating the number of carbon present in alkyl chain of the soap. The results showed that the impact of alkyl chain length on the stability of latex is in the order of laurate > decanoate > SDS > palmitate > purified latex accordingly. The alkyl chain length does giving a significant effect on latex stability after longer stirring time. The particle size of latex with the presence of surfactant is greater compare to a single particle itself due to extension of particles diameter. Thus suitable interaction of the nonpolar tail of surfactant with the hydrophobic regions of latex surface played a major role in maintaining a stable latex system. (author)

  9. Proteomic analysis of purified coronavirus infectious bronchitis virus particles

    Shu Dingming

    2010-06-01

    Full Text Available Abstract Background Infectious bronchitis virus (IBV is the coronavirus of domestic chickens causing major economic losses to the poultry industry. Because of the complexity of the IBV life cycle and the small number of viral structural proteins, important virus-host relationships likely remain to be discovered. Toward this goal, we performed two-dimensional gel electrophoresis fractionation coupled to mass spectrometry identification approaches to perform a comprehensive proteomic analysis of purified IBV particles. Results Apart from the virus-encoded structural proteins, we detected 60 host proteins in the purified virions which can be grouped into several functional categories including intracellular trafficking proteins (20%, molecular chaperone (18%, macromolcular biosynthesis proteins (17%, cytoskeletal proteins (15%, signal transport proteins (15%, protein degradation (8%, chromosome associated proteins (2%, ribosomal proteins (2%, and other function proteins (3%. Interestingly, 21 of the total host proteins have not been reported to be present in virions of other virus families, such as major vault protein, TENP protein, ovalbumin, and scavenger receptor protein. Following identification of the host proteins by proteomic methods, the presence of 4 proteins in the purified IBV preparation was verified by western blotting and immunogold labeling detection. Conclusions The results present the first standard proteomic profile of IBV and may facilitate the understanding of the pathogenic mechanisms.

  10. Characterization and treatment of cyanide in MGP purifier wastes

    Theis, T.L. [Clarkson University, Potsdam, NY (United States). Dept. of Civil and Environmental Engineering

    1995-12-31

    Purifier wastes were generated from the clean-up gaseous impurities, principally hydrogen sulfide and hydrogen cyanide, contained in raw gas from MGP operations through retention by iron oxide solids. These materials were generated at a rate of about 10-20 kg/1000 m{sup 3} of gas produced, and although regeneration was sometimes practised, eventual disposal as fill material, usually on site, was eventually necessary. The remediation of MGP sites generally requires that the disposition of these waste solids be addressed. The effective treatment of purifier wastes presents special problems due to the acid-base properties of the material, its elevated sulfur content, and the significant quantities of carbon both added as wood shavings and present as compounds generated as a result of gas manufacture. In broad terms, treatment approaches can be divided into two classes, those aimed at destroying the cyanide and objectionable carbon compounds and otherwise disposing of the residual, and those which attempt to isolate the waste from its surroundings. The latter approach attempts to take advantage of the natural insolubility of most of the constituents of concern found in purifier wastes, while destructive technologies limit potential liability. 9 refs.

  11. Occurrence and implications of methyl tert-butyl ether and gasoline hydrocarbons in ground water and source water in the United States and in drinking water in 12 Northeast and Mid-Atlantic States, 1993-2002

    Moran, Michael J.; Zogorski, John S.; Squillace, Paul J.

    2004-01-01

    The occurrence and implications of methyl tert-butyl ether (MTBE) and gasoline hydrocarbons were examined in three surveys of water quality conducted by the U.S. Geological Survey?one national-scale survey of ground water, one national-scale survey of source water from ground water, and one regional-scale survey of drinking water from ground water. The overall detection frequency of MTBE in all three surveys was similar to the detection frequencies of some other volatile organic compounds (VOCs) that have much longer production and use histories in the United States. The detection frequency of MTBE was higher in drinking water and lower in source water and ground water. However, when the data for ground water and source water were limited to the same geographic extent as drinking-water data, the detection frequencies of MTBE were comparable to the detection frequency of MTBE in drinking water. In all three surveys, the detection frequency of any gasoline hydrocarbon was less than the detection frequency of MTBE. No concentration of MTBE in source water exceeded the lower limit of U.S. Environmental Protection Agency's Drinking-Water Advisory of 20 ?g/L (micrograms per liter). One concentration of MTBE in ground water exceeded 20 ?g/L, and 0.9 percent of drinking-water samples exceeded 20 ?g/L. The overall detection frequency of MTBE relative to other widely used VOCs indicates that MTBE is an important concern with respect to ground-water management. The probability of detecting MTBE was strongly associated with population density, use of MTBE in gasoline, and recharge, and weakly associated with density of leaking underground storage tanks, soil permeability, and aquifer consolidation. Only concentrations of MTBE above 0.5 ?g/L were associated with dissolved oxygen. Ground water underlying areas with high population density, ground water underlying areas where MTBE is used as a gasoline oxygenate, and ground water underlying areas with high recharge has a greater

  12. Ground-Water Quality Data in the Santa Clara River Valley Study Unit, 2007: Results from the California GAMA Program

    Montrella, Joseph; Belitz, Kenneth

    2009-01-01

    Ground-water quality in the approximately 460-square-mile Santa Clara River Valley study unit (SCRV) was investigated from April to June 2007 as part of the statewide Priority Basin project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw ground water used for public water supplies within SCRV, and to facilitate a statistically consistent basis for comparing water quality throughout California. Fifty-seven ground-water samples were collected from 53 wells in Ventura and Los Angeles Counties. Forty-two wells were selected using a randomized grid-based method to provide statistical representation of the study area (grid wells). Eleven wells (understanding wells) were selected to further evaluate water chemistry in particular parts of the study area, and four depth-dependent ground-water samples were collected from one of the eleven understanding wells to help understand the relation between water chemistry and depth. The ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, potential wastewater-indicator compounds, and pharmaceutical compounds), a constituent of special interest (perchlorate), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial constituents. Naturally occurring isotopes (tritium, carbon-13, carbon-14 [abundance], stable isotopes of hydrogen and oxygen in water, stable isotopes of nitrogen and oxygen in nitrate, chlorine-37, and bromine-81), and dissolved noble gases also were measured to help identify the source

  13. Risks to Water Resources from Shale Gas Development and Hydraulic Fracturing in the United States

    Vengosh, Avner; Jackson, Robert B.; Warner, Nathaniel; Darrah, Thomas H.; Kondash, Andrew

    2014-05-01

    The rise of shale gas development through horizontal drilling and high volume hydraulic fracturing has expanded oil and gas exploration in the USA. The rapid rate of shale gas exploration has triggered an intense public debate regarding the potential environmental and human health effects. A review of the updated literature has identified four potential risks for impacts on water resources: (1) stray gas contamination of shallow aquifers near shale gas sites; (2) contamination of surface water and shallow groundwater from spills, leaks, and disposal of inadequately treated wastewater or hydraulic fracturing fluids; (3) accumulation of toxic and radioactive residues in soil or stream sediments near disposal or spill sites; and (4) over-extraction of water resources for drilling and hydraulic fracturing that could induce water shortages and conflicts with other water users, particularly in water-scarce areas. As part of a long-term research on the potential water contamination associated with shale gas development, new geochemical and isotopic techniques have been developed for delineating the origin of gases and contaminants in water resource. In particular, multiple geochemical and isotopic (carbon isotopes in hydrocarbons, noble gas, strontium, boron, radium isotopes) tracers have been utilized to distinguish between naturally occurring dissolved gas and salts in water and contamination directly induced from shale gas drilling and hydraulic fracturing operations.

  14. Economics of residential gas furnaces and water heaters in United States new construction market

    Lekov, Alex B.; Franco, Victor H.; Wong-Parodi, Gabrielle; McMahon, James E.; Chan, Peter

    2009-05-06

    New single-family home construction represents a significant and important market for the introduction of energy-efficient gas-fired space heating and water-heating equipment. In the new construction market, the choice of furnace and water-heater type is primarily driven by first cost considerations and the availability of power vent and condensing water heaters. Few analysis have been performed to assess the economic impacts of the different combinations of space and water-heating equipment. Thus, equipment is often installed without taking into consideration the potential economic and energy savings of installing space and water-heating equipment combinations. In this study, we use a life-cycle cost analysis that accounts for uncertainty and variability of the analysis inputs to assess the economic benefits of gas furnace and water-heater design combinations. This study accounts not only for the equipment cost but also for the cost of installing, maintaining, repairing, and operating the equipment over its lifetime. Overall, this study, which is focused on US single-family new construction households that install gas furnaces and storage water heaters, finds that installing a condensing or power-vent water heater together with condensing furnace is the most cost-effective option for the majority of these houses. Furthermore, the findings suggest that the new construction residential market could be a target market for the large-scale introduction of a combination of condensing or power-vent water heaters with condensing furnaces.

  15. Implications of water constraints for electricity capacity expansion in the United States

    Liu, L.; Hejazi, M. I.; Iyer, G.; Forman, B. A.

    2017-12-01

    U.S. electricity generation is vulnerable to water supply since water is required for cooling. Constraints on the availability of water will therefore necessitate adaptive planning by the power generation sector. Hence, it is important to integrate restrictions in water availability in electricity capacity planning in order to better understand the economic viability of alternative capacity planning options. The study of the implications of water constraints for the U.S. power generation system is limited in terms of scale and robustness. We extend previous studies by including physical water constraints in a state-level model of the U.S. energy system embedded within a global integrated assessment model (GCAM-USA). We focus on the implications of such constraints for the U.S. electricity capacity expansion, integrating both supply and demand effects under a consistent framework. Constraints on the availability of water have two general effects across the U.S. First, water availability constraints increase the cost of electricity generation, resulting in reduced electrification of end-use sectors. Second, water availability constraints result in forced retirements of water-intensive technologies such as thermoelectric coal- and gas- fired technologies before the end of their natural lifetimes. The demand for electricity is then met by an increase in investments in less water-dependent technologies such as wind and solar photovoltaic. Our results show that the regional patterns of the above effects are heterogeneous across the U.S. In general, the impacts of water constraints on electricity capacity expansion are more pronounced in the West than in the East. This is largely because of lower water availability in the West compared to the East due to lower precipitation in the Western states. Constraints on the availability of water might also have important implications for U.S. electricity trade. For example, under severe constraints on the availability of water

  16. Ground-Water Quality Data in the Kern County Subbasin Study Unit, 2006 - Results from the California GAMA Program

    Shelton, Jennifer L.; Pimentel, Isabel; Fram, Miranda S.; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 3,000 square-mile Kern County Subbasin study unit (KERN) was investigated from January to March, 2006, as part of the Priority Basin Assessment Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Assessment project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the California State Water Resources Control Board (SWRCB) in collaboration with the U.S. Geological Survey (USGS) and the Lawrence Livermore National Laboratory (LLNL). The Kern County Subbasin study was designed to provide a spatially unbiased assessment of raw (untreated) ground-water quality within KERN, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 50 wells within the San Joaquin Valley portion of Kern County. Forty-seven of the wells were selected using a randomized grid-based method to provide a statistical representation of the ground-water resources within the study unit. Three additional wells were sampled to aid in the evaluation of changes in water chemistry along regional ground-water flow paths. The ground-water samples were analyzed for a large number of man-made organic constituents (volatile organic compounds [VOCs], pesticides, and pesticide degradates), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, carbon-14, and stable isotopes of hydrogen, oxygen, nitrogen, and carbon) and dissolved noble gases also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blanks, replicates, and laboratory matrix spikes) were collected and analyzed at approximately 10 percent of

  17. Ground-Water Quality Data in the Central Sierra Study Unit, 2006 - Results from the California GAMA Program

    Ferrari, Matthew J.; Fram, Miranda S.; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 950 square kilometer (370 square mile) Central Sierra study unit (CENSIE) was investigated in May 2006 as part of the Priority Basin Assessment project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Assessment project was developed in response to the Ground-Water Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). This study was designed to provide a spatially unbiased assessment of the quality of raw ground water used for drinking-water supplies within CENSIE, and to facilitate statistically consistent comparisons of ground-water quality throughout California. Samples were collected from thirty wells in Madera County. Twenty-seven of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and three were selected to aid in evaluation of specific water-quality issues (understanding wells). Ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], gasoline oxygenates and degradates, pesticides and pesticide degradates), constituents of special interest (N-nitrosodimethylamine, perchlorate, and 1,2,3-trichloropropane), naturally occurring inorganic constituents [nutrients, major and minor ions, and trace elements], radioactive constituents, and microbial indicators. Naturally occurring isotopes [tritium, and carbon-14, and stable isotopes of hydrogen, oxygen, nitrogen, and carbon], and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. In total, over 250 constituents and water-quality indicators were investigated. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at approximately one-sixth of the wells, and

  18. Climatic and physiographic controls of spatial variability in surface water balance over the contiguous United States using the Budyko relationship

    Abatzoglou, John T.; Ficklin, Darren L.

    2017-09-01

    The geographic variability in the partitioning of precipitation into surface runoff (Q) and evapotranspiration (ET) is fundamental to understanding regional water availability. The Budyko equation suggests this partitioning is strictly a function of aridity, yet observed deviations from this relationship for individual watersheds impede using the framework to model surface water balance in ungauged catchments and under future climate and land use scenarios. A set of climatic, physiographic, and vegetation metrics were used to model the spatial variability in the partitioning of precipitation for 211 watersheds across the contiguous United States (CONUS) within Budyko's framework through the free parameter ω. A generalized additive model found that four widely available variables, precipitation seasonality, the ratio of soil water holding capacity to precipitation, topographic slope, and the fraction of precipitation falling as snow, explained 81.2% of the variability in ω. The ω model applied to the Budyko equation explained 97% of the spatial variability in long-term Q for an independent set of watersheds. The ω model was also applied to estimate the long-term water balance across the CONUS for both contemporary and mid-21st century conditions. The modeled partitioning of observed precipitation to Q and ET compared favorably across the CONUS with estimates from more sophisticated land-surface modeling efforts. For mid-21st century conditions, the model simulated an increase in the fraction of precipitation used by ET across the CONUS with declines in Q for much of the eastern CONUS and mountainous watersheds across the western United States.

  19. Modeled Sources, Transport, and Accumulation of Dissolved Solids in Water Resources of the Southwestern United States.

    Anning, David W

    2011-10-01

    Information on important source areas for dissolved solids in streams of the southwestern United States, the relative share of deliveries of dissolved solids to streams from natural and human sources, and the potential for salt accumulation in soil or groundwater was developed using a SPAtially Referenced Regressions On Watershed attributes model. Predicted area-normalized reach-catchment delivery rates of dissolved solids to streams ranged from Salton Sea accounting unit.

  20. Regulatory analysis for the resolution of Generic Issue 130: Essential service water system failures at multi-unit sites

    Leung, V.; Basdekas, D.; Mazetis, G.

    1991-06-01

    The essential service water system (ESWS) is required to provide cooling in nuclear power plants during normal operation and accident conditions. The ESWS typically supports component cooling water heat exchangers, containment spray heat exchangers, high-pressure injection pump oil coolers, emergency diesel generators, and auxiliary building ventilation coolers. Failure of the ESWS function could lead to severe consequences. This report presents the regulatory analysis for GI-130, ''Essential Service Water System Failures at Multi-Unit Sites.'' The risk reduction estimates, cost/benefit analyses, and other insights gained during this effort have shown that implementation of the recommendations will significantly reduce risk and that these improvements are warranted in accordance with the backfit rule, 10 CFR 50.109(a)(3). 19 refs., 16 tabs

  1. Determination of maximum water temperature within the spent fuel pool of Angra Nuclear Power Plant - Unit 3

    Werner, F.L., E-mail: fernanda.werner@poli.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Departamento de Engenharia Nuclear; Alves, A.S.M., E-mail: asergi@eletronuclear.gov.br [Eletrobras Termonuclear (Eletronuclear), Rio de Janeiro, RJ (Brazil); Frutuoso e Melo, P.F., E-mail: frutuoso@nuclear.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    In this paper, a mathematical model for the determination of the maximum water temperature within the spent fuel pool of Angra Nuclear Power Plant – Unit 3 was developed. The model was obtained from the boundary layer analysis and the application of Navier-Stokes equation to a vertical flat plate immersed in a water flow under free convection regime. Both types of pressure loss coefficients through the flow channel were considers in the modeling, the form coefficient for fuel assemblies (FAs) and the loss due to rod friction. The resulting equations enabled the determination of a mixed water temperature below the storage racks (High Density Storage Racks) as well as the estimation of a temperature gradient through the racks. The model was applied to the authorized operation of the plant (power operation, plant outage and upset condition) and faulted conditions (loss of coolant accidents and external events). The results obtained are in agreement with Brazilian and international standards. (author)

  2. Determination of maximum water temperature within the spent fuel pool of Angra Nuclear Power Plant - Unit 3

    Werner, F.L.; Frutuoso e Melo, P.F.

    2017-01-01

    In this paper, a mathematical model for the determination of the maximum water temperature within the spent fuel pool of Angra Nuclear Power Plant – Unit 3 was developed. The model was obtained from the boundary layer analysis and the application of Navier-Stokes equation to a vertical flat plate immersed in a water flow under free convection regime. Both types of pressure loss coefficients through the flow channel were considers in the modeling, the form coefficient for fuel assemblies (FAs) and the loss due to rod friction. The resulting equations enabled the determination of a mixed water temperature below the storage racks (High Density Storage Racks) as well as the estimation of a temperature gradient through the racks. The model was applied to the authorized operation of the plant (power operation, plant outage and upset condition) and faulted conditions (loss of coolant accidents and external events). The results obtained are in agreement with Brazilian and international standards. (author)

  3. Evaluating the energy and CO2 emissions impacts of shifts in residential water heating in the United States

    Sanders, Kelly T.; Webber, Michael E.

    2015-01-01

    Water heating represented nearly 13% of 2010 residential energy consumption making it an important target for energy conservation efforts. The objective of this work is to identify spatially-resolved strategies for energy conservation, since little analysis has been done to identify how regional characteristics affect the energy consumed for water heating. We present a first-order thermodynamic analysis, utilizing ab initio calculations and regression methods, to quantify primary energy consumption and CO 2 emissions with regional specificity by considering by considering local electricity mixes, heat rates, solar radiation profiles, heating degrees days, and water heating unit sales for 27 regions of the US. Results suggest that shifting from electric towards natural gas or solar water heating offered primary energy and CO 2 emission reductions in most US regions, but these reductions varied considerably according to regional electricity mix and solar resources. We find that regions that would benefit most from technology transitions, are often least likely to switch due to limited economic incentives. Our results suggest that federal energy factor metrics, which ignore upstream losses in power generation, are insufficient in informing consumers about the energy performance of residential end use appliances. - Highlights: • US energy factor ratings for water heaters ignore upstream losses. • Switching from electric storage water heating reduces CO 2 emissions in most US regions. • Regions with greatest potential for CO 2 avoidance are least likely to shift technologies. • Benefits vary significantly according to climate and regional electricity fuel mix

  4. Comparison of Advanced Residential Water Heating Technologies in the United States

    Maguire, J.; Fang, X.; Wilson, E.

    2013-05-01

    Gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the US installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many preexisting models were used, new models of condensing and heat pump water heaters were created specifically for this work.

  5. Water Pollution Control Training: The Educational Role of the United States Environmental Protection Agency.

    Williams, Frederick D.

    Presented are the results of a study to determine the perceived needs of environmental control education programs as seen by students, instructors, deans or program directors, and field-related employers in the field of water pollution control. Data were collected utilizing three approaches: survey instruments, information from Water Quality…

  6. The Effects of a Water Conservation Instructional Unit on the Values Held by Sixth Grade Students

    Aird, Andrew; Tomera, Audrey

    1977-01-01

    Sixth grade students were divided into two groups. Students in one group received instruction on water conservation using expository and discovery activities. The students in the control group received none. Results gave evidence that students' values could be changed by this mode of water conservation instruction. (MA)

  7. Black yeasts-like fungi isolated from dialysis water in hemodialysis units

    Figel, Izabel Cristina; Marangoni, Paulo Roberto Dantas; Tralamazza, Sabina Moser; Vicente, Vânia Aparecida; Dalzoto, Patrícia do Rocio; do Nascimento, Mariana Machado Fidelis; de Hoog, G Sybren; Pimentel, Ida Chapaval

    Hemodialysis in patients with chronic renal failure promotes the removal of toxic substances, water, and minerals from the body and often takes place in specialized clinics. Microbial contamination of dialysis fluid is a serious problem in therapy. One of the sources of contamination is the water

  8. Water conservation and hydrological transitions in cities in the United States

    Hornberger, George M.; Hess, David J.; Gilligan, Jonathan

    2015-06-01

    Cities across the world have had to diversify and expand their water supply systems in response to demand growth, groundwater depletion and pollution, and instability and inadequacy of regional surface freshwater sources. In the U.S., these problems plague not only the arid Western cities but increasingly also cities in the Eastern portions of the country. Although cities continue to seek out new sources of water via Promethean projects of long-distance supply systems, desalinization plants, and the recharge of aquifers with surface water, they also pursue water conservation because of its low cost and other benefits. We examine water conservation as a complex sociotechnical system comprising interactions of political, sociodemographic, economic, and hydroclimatological factors. We provide quantitative data on the factors that affect more and less advanced transitions in water conservation regimes, and we show that water stress and other hydrological data can only partially predict the transition. We also provide qualitative case studies to identify institutional and political barriers to more advanced water conservation regimes. This interdisciplinary, mixed methods approach typifies the need for knowledge that informs hydrologists about how their research may or may not be adopted by decision-makers.

  9. 78 FR 67336 - Habitat Conservation Plan for the United Water Conservation District, Santa Clara River Watershed...

    2013-11-12

    ... listed fish, by significantly impairing essential behavioral patterns, including breeding, feeding, and... degradation where it actually kills or injures fish or wildlife by significantly impairing essential... biological resources, land use, air quality, water quality, water resources, socio-economics, climate, and...

  10. Ground-Water Quality Data in the San Francisco Bay Study Unit, 2007: Results from the California GAMA Program

    Ray, Mary C.; Kulongoski, Justin T.; Belitz, Kenneth

    2009-01-01

    Ground-water quality in the approximately 620-square-mile San Francisco Bay study unit (SFBAY) was investigated from April through June 2007 as part of the Priority Basin project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of raw ground-water quality, as well as a statistically consistent basis for comparing water quality throughout California. Samples in SFBAY were collected from 79 wells in San Francisco, San Mateo, Santa Clara, Alameda, and Contra Costa Counties. Forty-three of the wells sampled were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells). Thirty-six wells were sampled to aid in evaluation of specific water-quality issues (understanding wells). The ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicator compounds), constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]), naturally occurring inorganic constituents (nutrients, major and minor ions, trace elements, chloride and bromide isotopes, and uranium and strontium isotopes), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, carbon-14 isotopes, and stable isotopes of hydrogen, oxygen, nitrogen, boron, and carbon), and dissolved noble gases (noble gases were analyzed in collaboration with Lawrence Livermore National Laboratory) also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blank samples

  11. Surveillance for waterborne disease and outbreaks associated with drinking water and water not intended for drinking--United States, 2005-2006.

    Yoder, Jonathan; Roberts, Virginia; Craun, Gunther F; Hill, Vincent; Hicks, Lauri A; Alexander, Nicole T; Radke, Vince; Calderon, Rebecca L; Hlavsa, Michele C; Beach, Michael J; Roy, Sharon L

    2008-09-12

    Since 1971, CDC, the U.S. Environmental Protection Agency (EPA), and the Council of State and Territorial Epidemiologists have maintained a collaborative Waterborne Disease and Outbreak Surveillance System (WBDOSS) for collecting and reporting data related to occurrences and causes of waterborne-disease outbreaks (WBDOs) and cases of waterborne disease. This surveillance system is the primary source of data concerning the scope and effects of waterborne disease in the United States. Data presented summarize 28 WBDOs that occurred during January 2005--December 2006 and four previously unreported WBDOs that occurred during 1979--2002. The surveillance system includes data on WBDOs associated with recreational water, drinking water, water not intended for drinking (WNID) (excluding recreational water), and water use of unknown intent. Public health departments in the states, territories, localities, and Freely Associated States (FAS) (i.e., the Republic of the Marshall Islands, the Federated States of Micronesia, and the Republic of Palau, formerly parts of the U.S.-administered Trust Territory of the Pacific Islands) are primarily responsible for detecting and investigating WBDOs and voluntarily reporting them to CDC by a standard form. Only cases and outbreaks associated with drinking water, WNID (excluding recreational water), and water of unknown intent (WUI) are summarized in this report. Cases and outbreaks associated with recreational water are reported in a separate Surveillance Summary. Fourteen states reported 28 WBDOs that occurred during 2005--2006: a total of 20 were associated with drinking water, six were associated with WNID, and two were associated with WUI. The 20 drinking water-associated WBDOs caused illness among an estimated 612 persons and were linked to four deaths. Etiologic agents were identified in 18 (90.0%) of the drinking water-associated WBDOs. Among the 18 WBDOs with identified pathogens, 12 (66.7%) were associated with bacteria, three

  12. Waterflood using a muskeg water source Milligan Creek Unit, B. C

    Cracknell, W C

    1968-01-01

    The Milligan Creek field, in NE. British Columbia, is a small but high capacity sand reservoir of Triassic age. Waterflooding was initiated early in the life of the reservoir to provide pressure maintenance and increase oil recovery from the pool. Due to the lack of a subsurface supply in the area, muskeg water from a nearby creek was utilized. This cold water with its high content or iron and organic material has proven to be a major water treatment problem. After considerable experimentation a process using flocculation, filtration through a sand- anthracite filter, and deaeration was found to yield water satisfactory for injection. Seasonal variation in water quality remains a problem. Four years of waterflooding have yielded satisfactory results with a decrease in voidage, an increase in reservoir pressure and the attainment of a high level of production for a pool of this size. Performance has been accurately predicted by means of a potentiometric model.

  13. Irrigation-induced contamination of water, sediment, and biota in the western United States-synthesis of data from the National Irrigation Water Quality Program

    Seiler, Ralph L.; Skorupa, Joseph P.; Naftz, David L.; Nolan, B. Thomas

    2003-01-01

    In October 1985 the U.S. Department of the Interior (DOI), through the National Irrigation Water Quality Program (NIWQP), began a series of field investigations at 26 areas in the Western United States to determine whether irrigation drainage has had harmful effects on fish, wildlife, and humans or has reduced beneficial uses of water. In 1992 NIWQP initiated the Data Synthesis Project to evaluate data collected during the field investigations. Geologic, climatologic, and hydrologic data were evaluated and water, sediment, and biota from the 26 areas were analyzed to identify commonalities and dominant factors that result in irrigation-induced contamination of water and biota. Data collected for the 26 area investigations have been compiled and merged into a common data base. The structure of the data base is designed to enable assessment of relations between contaminant concentrations in water, sediment, and biota. The data base is available to the scientific community through the World Wide Web at URL http://www.usbr.gov/niwqp. Analysis of the data base for the Data Synthesis included use of summary statistics, factor analysis, and logistic regression. A Geographic Information System was used to store and analyze spatially oriented digital data such as land use, geology and evaporation rates. In the U.S. Department of the Interior (DOI) study areas, samples of water, bottom sediment, and biota were collected for trace-element and pesticide analysis. Contaminants most commonly associated with irrigation drainage were identified by comparing concentrations in water with established criteria. For surface water, the criteria used were typically chronic criteria for the protection of freshwater aquatic life. Because ground water can discharge to the surface where wildlife can be exposed to it, the criteria used for ground water were both the maximum contaminant levels (MCL's) for drinking water and the chronic criteria for the protection of freshwater aquatic life

  14. Surveillance for waterborne disease and outbreaks associated with drinking water and water not intended for drinking--United States, 2003-2004.

    Liang, Jennifer L; Dziuban, Eric J; Craun, Gunther F; Hill, Vincent; Moore, Matthew R; Gelting, Richard J; Calderon, Rebecca L; Beach, Michael J; Roy, Sharon L

    2006-12-22

    Since 1971, CDC, the U.S. Environmental Protection Agency (EPA), and the Council of State and Territorial Epidemiologists have maintained a collaborative Waterborne Disease and Outbreaks Surveillance System for collecting and reporting data related to occurrences and causes of waterborne disease and outbreaks (WBDOs). This surveillance system is the primary source of data concerning the scope and effects of WBDOs in the United States. Data presented summarize 36 WBDOs that occurred during January 2003-December 2004 and nine previously unreported WBDOs that occurred during 1982-2002. The surveillance system includes data on WBDOs associated with drinking water, water not intended for drinking (excluding recreational water), and water of unknown intent. Public health departments in the states, territories, localities, and Freely Associated States (i.e., the Republic of the Marshall Islands, the Federated States of Micronesia, and the Republic of Palau, formerly parts of the U.S.-administered Trust Territory of the Pacific Islands) are primarily responsible for detecting and investigating WBDOs and voluntarily reporting them to CDC by using a standard form. During 2003-2004, a total of 36 WBDOs were reported by 19 states; 30 were associated with drinking water, three were associated with water not intended for drinking, and three were associated with water of unknown intent. The 30 drinking water-associated WBDOs caused illness among an estimated 2,760 persons and were linked to four deaths. Etiologic agents were identified in 25 (83.3%) of these WBDOs: 17 (68.0%) involved pathogens (i.e., 13 bacterial, one parasitic, one viral, one mixed bacterial/parasitic, and one mixed bacterial/parasitic/viral), and eight (32.0%) involved chemical/toxin poisonings. Gastroenteritis represented 67.7% of the illness related to drinking water-associated WBDOs; acute respiratory illness represented 25.8%, and dermatitis represented 6.5%. The classification of deficiencies contributing

  15. Trends in the occurrence of MTBE in drinking water in the Northeast United States

    Moran, M.J.

    2007-01-01

    Public water systems in Connecticut, Maine, Maryland, New Hampshire, New Jersey, and Rhode Island sampled treated drinking water from 1993-2006 and analyzed the samples for MTBE. The US Geological Survey examined trends in the occurrence of MTBE in drinking water derived from ground water in these States for two near-decadal time steps; 1993-1999 and 2000-2006. MTBE was detected in 14% of drinking water samples collected in all States from 1993-1999 and in 19% of drinking water samples collected from the same systems from 2000-2006 and this difference was statistically significant. Trends in the occurrence of MTBE in each State by individual year indicated significant positive trends in Maryland and New Hampshire. Significant, increasing trends in MTBE concentrations were observed in Maryland and Rhode Island by individual year. This is an abstract of a paper presented at the 2007 Petroleum Hydrocarbons and Organic Chemicals in Ground Water: Prevention, Assessment and Remediation Conference (Houston, TX 11/5-6/2007).

  16. ENEA`s mobile treatment units for specific waters; Impianti mobili ENEA di trattamento / smaltimento rifiuti

    Beone, G.; Barni, E.; Coronidi, M. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Ambiente; Bortone, G.; Gambaro, L.; Zanetti, P. [ENEA, Centro Ricerche `Ezio Clementel, Bologna (Italy). Dipt. Ambiente; Liccione, G. [ENEA, Centro Ricerche Trisaia, Matera (Italy). Dipt. Ambiente; Zanin, E.

    1997-11-01

    Solid waste production in turistic places is characterized by a large increase, up to 80 % for few months during the year. Generally a waste treatment plant is designed for a mean production and can support increases that non exceed 10 %. Treatment plants with higher capacity are not economically convenient and the excedent production is landfilled. An answer to this problem are mobile treatment units that could be used to support resident plants when higher treatment capacity is requested. Mobile units are very useful for other uses like as treatment of specific wastes (agricultural plastic bags and sheets contaminated by antiparasitics and herbicides) infective wastes from hospital and laboratories and leaches from landfills. Mobile units flexibility is also important for environmental protection actions, either scheduled on in an emergency, like as reclamation of contaminated soils, asbestos contaminated site and every time when waste transport is characterized by high cost or safety and sanitary problems.

  17. EnviroAtlas - Thermoelectric Water Use by 12-Digit HUC for the Conterminous United States

    U.S. Environmental Protection Agency — This EnviroAtlas dataset is a summary of the thermoelectric water consumption based on the December 2016 US Energy Information Administration (EIA) monthly electric...

  18. Can Phlorotannins Purified Extracts Constitute a Novel Pharmacological Alternative for Microbial Infections with Associated Inflammatory Conditions?

    Lopes, Graciliana; Sousa, Carla; Silva, Luís R.; Pinto, Eugénia; Andrade, Paula B.; Bernardo, João; Mouga, Teresa; Valentão, Patrícia

    2012-01-01

    Bacterial and fungal infections and the emerging multidrug resistance are driving interest in fighting these microorganisms with natural products, which have generally been considered complementary to pharmacological therapies. Phlorotannins are polyphenols restricted to brown seaweeds, recognized for their biological capacity. This study represents the first research on the antibacterial, antifungal, anti-inflammatory and antioxidant activity of phlorotannins purified extracts, which were obtained from ten dominant brown seaweeds of the occidental Portuguese coast. Phlorotannins content was determined by the specific dimethoxybenzaldehyde (DMBA) method and a yield between 75 and 969 mg/Kg phloroglucinol units (dry matter) was obtained. Fucus spiralis ranked first, followed by three Cystoseira species. The anti-inflammatory potential of the purified extracts was assessed via inhibitory effect on nitric oxide (NO) production by lipopolysaccharide-stimulated RAW 264.7 macrophage cells, Cystoseira tamariscifolia being the one showing promising activity for the treatment of inflammation. NO scavenging ability was also addressed in cell free systems, F. spiralis being the species with highest capacity. The antimicrobial potential of the extracts was checked against five Gram-positive and four Gram-negative bacteria and three fungi strains, that commonly colonize skin and mucosa and are responsible for food contamination. The different extracts were more effective against Gram-positive bacteria, Staphylococcus epidermidis being the most susceptible species. Concerning antifungal activity, Trichophyton rubrum was the most sensitive species. Although the molecular mechanisms underlying these properties remain poorly understood, the results obtained turn phlorotannins purified extracts a novel and potent pharmacological alternative for the treatment of a wide range of microbial infections, which usually also present an inflammatory component. In addition to the biological

  19. Consumer Behavior Modeling: Fuzzy Logic Model for Air Purifiers Choosing

    Oleksandr Dorokhov

    2017-12-01

    Full Text Available At the beginning, the article briefly describes the features of the marketing complex household goods. Also provides an overview of some aspects of the market for indoor air purifiers. The specific subject of the study was the process of consumer choice of household appliances for cleaning air in living quarters. The aim of the study was to substantiate and develop a computer model for evaluating by the potential buyers devices for air purification in conditions of vagueness and ambiguity of their consumer preferences. Accordingly, the main consumer criteria are identified, substantiated and described when buyers choose air purifiers. As methods of research, approaches based on fuzzy logic, fuzzy sets theory and fuzzy modeling were chosen. It was hypothesized that the fuzzy-multiple model allows rather accurately reflect consumer preferences and potential consumer choice in conditions of insufficient and undetermined information. Further, a computer model for estimating the consumer qualities of air cleaners by customers is developed. A proposed approach based on the application of fuzzy logic theory and practical modeling in the specialized computer software MATLAB. In this model, the necessary membership functions and their terms are constructed, as well as a set of rules for fuzzy inference to make decisions on the estimation of a specific air purifier. A numerical example of a comparative evaluation of air cleaners presented on the Ukrainian market is made and is given. Numerical simulation results confirmed the applicability of the proposed approach and the correctness of the hypothesis advanced about the possibility of modeling consumer behavior using fuzzy logic. The analysis of the obtained results is carried out and the prospects of application, development, and improvement of the developed model and the proposed approach are determined.

  20. Drivers of Variability in Public-Supply Water Use Across the Contiguous United States

    Worland, Scott C.; Steinschneider, Scott; Hornberger, George M.

    2018-03-01

    This study explores the relationship between municipal water use and an array of climate, economic, behavioral, and policy variables across the contiguous U.S. The relationship is explored using Bayesian-hierarchical regression models for over 2,500 counties, 18 covariates, and three higher-level grouping variables. Additionally, a second analysis is included for 83 cities where water price and water conservation policy information is available. A hierarchical model using the nine climate regions (product of National Oceanic and Atmospheric Administration) as the higher-level groups results in the best out-of-sample performance, as estimated by the Widely Available Information Criterion, compared to counties grouped by urban continuum classification or primary economic activity. The regression coefficients indicate that the controls on water use are not uniform across the nation: e.g., counties in the Northeast and Northwest climate regions are more sensitive to social variables, whereas counties in the Southwest and East North Central climate regions are more sensitive to environmental variables. For the national city-level model, it appears that arid cities with a high cost of living and relatively low water bills sell more water per customer, but as with the county-level model, the effect of each variable depends heavily on where a city is located.

  1. High-resolution Continental Scale Land Surface Model incorporating Land-water Management in United States

    Shin, S.; Pokhrel, Y. N.

    2016-12-01

    Land surface models have been used to assess water resources sustainability under changing Earth environment and increasing human water needs. Overwhelming observational records indicate that human activities have ubiquitous and pertinent effects on the hydrologic cycle; however, they have been crudely represented in large scale land surface models. In this study, we enhance an integrated continental-scale land hydrology model named Leaf-Hydro-Flood to better represent land-water management. The model is implemented at high resolution (5km grids) over the continental US. Surface water and groundwater are withdrawn based on actual practices. Newly added irrigation, water diversion, and dam operation schemes allow better simulations of stream flows, evapotranspiration, and infiltration. Results of various hydrologic fluxes and stores from two sets of simulation (one with and the other without human activities) are compared over a range of river basin and aquifer scales. The improved simulations of land hydrology have potential to build consistent modeling framework for human-water-climate interactions.

  2. Ferromagnetic Levan Composite: An Affinity Matrix to Purify Lectin

    Renata Angeli

    2009-01-01

    Full Text Available A simple and inexpensive procedure used magnetite and levan to synthesize a composite recovered by a magnetic field. Lectins from Canavalia ensiformis (Con A and Cratylia mollis (Cramoll 1 and Cramoll 1,4 did bind specifically to composite. The magnetic property of derivative favored washing out contaminating proteins and recovery of pure lectins with glucose elution. Cramoll 1 was purified by this affinity binding procedure in two steps instead of a previous three-step protocol with ammonium sulfate fractionation, affinity chromatography on Sephadex G-75, and ion exchange chromatography through a CM-cellulose column.

  3. Water withdrawals and trends from the Floridan aquifer system in the southeastern United States, 1950-2000

    Marella, Richard L.; Berndt, Marian P.

    2005-01-01

    The Floridan aquifer system in the southeastern United States is one of the most productive aquifers in the world (Miller, 1990). This aquifer system underlies an area of about 100,000 square miles in southern Alabama, eastern and southern Georgia, southeastern Mississippi, southern South Carolina, and all of Florida. The Floridan aquifer system is the primary source of water for nearly 10 million people and supports agriculture, industry, and tourism throughout most of the region. In most areas, water from this aquifer is potable and needs very little treatment before use. However, in southern Florida (south of Lake Okeechobee), northwestern Florida and southern Alabama and Mississippi (Pensacola and westward), and eastern South Carolina, water in the aquifer system generally is not potable. The purpose of this report is to: Provide a general description of the Floridan aquifer system; Discuss water withdrawals by category for 2000; Highlight trends in water withdrawals between 1950 and 2000; and Provide a brief summary on the effects that human impacts have on the Floridan aquifer system.

  4. Ground-Water Quality Data in the Southern Sierra Study Unit, 2006 - Results from the California GAMA Program

    Fram, Miranda S.; Belitz, Kenneth

    2007-01-01

    Ground-water quality in the approximately 1,800 square-mile Southern Sierra study unit (SOSA) was investigated in June 2006 as part of the Statewide Basin Assessment Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Statewide Basin Assessment Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Southern Sierra study was designed to provide a spatially unbiased assessment of raw ground-water quality within SOSA, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from fifty wells in Kern and Tulare Counties. Thirty-five of the wells were selected using a randomized grid-based method to provide statistical representation of the study area, and fifteen were selected to evaluate changes in water chemistry along ground-water flow paths. The ground-water samples were analyzed for a large number of synthetic organic constituents [volatile organic compounds (VOCs), pesticides and pesticide degradates, pharmaceutical compounds, and wastewater-indicator compounds], constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), and 1,2,3-trichloropropane (1,2,3-TCP)], naturally occurring inorganic constituents [nutrients, major and minor ions, and trace elements], radioactive constituents, and microbial indicators. Naturally occurring isotopes [tritium, and carbon-14, and stable isotopes of hydrogen and oxygen in water], and dissolved noble gases also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected for approximately one-eighth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the

  5. Electrodialysis-based separation process for salt recovery and recycling from waste water

    Tsai, Shih-Perng

    1997-01-01

    A method for recovering salt from a process stream containing organic contaminants is provided, comprising directing the waste stream to a desalting electrodialysis unit so as to create a concentrated and purified salt permeate and an organic contaminants containing stream, and contacting said concentrated salt permeate to a water-splitting electrodialysis unit so as to convert the salt to its corresponding base and acid.

  6. TiO2-Impregnated Porous Silica Tube and Its Application for Compact Air- and Water-Purification Units

    Tsuyoshi Ochiai

    2015-09-01

    Full Text Available A simple, convenient, reusable, and inexpensive air- and water-purification unit including a one-end sealed porous amorphous-silica (a-silica tube coated with TiO2 photocatalyst layers has been developed. The porous a-silica layers were formed through outside vapor deposition (OVD. TiO2 photocatalyst layers were formed through impregnation and calcination onto a-silica layers. The resulting porous TiO2-impregnated a-silica tubes were evaluated for air-purification capacity using an acetaldehyde gas decomposition test. The tube (8.5 mm e.d. × 150 mm demonstrated a 93% removal rate for high concentrations (ca. 300 ppm of acetaldehyde gas at a single-pass condition with a 250 mL/min flow rate under UV irradiation. The tube also demonstrated a water purification capacity at a rate 2.0 times higher than a-silica tube without TiO2 impregnation. Therefore, the tubes have a great potential for developing compact and in-line VOC removal and water-purification units.

  7. Iron turbidity removal from the active process water system of the Kaiga Generating Station Unit 1 using an electrochemical filter

    Venkateswaran, G.; Gokhale, B.K.

    2007-01-01

    Iron turbidity is observed in the intermediate cooling circuit of the active process water system (APWS) of Kaiga Generating Station (KGS). Deposition of hydrous/hydrated oxides of iron on the plate type heat exchanger, which is employed to transfer heat from the APWS to the active process cooling water system (APCWS), can in turn result in higher moderator D 2 O temperatures due to reduced heat transfer. Characterization of turbidity showed that the major component is γ-FeOOH. An in-house designed and fabricated electrochemical filter (ECF) containing an alternate array of 33 pairs of cathode and anode graphite felts was successfully tested for the removal of iron turbidity from the APWS of Kaiga Generating Station Unit No. 1 (KGS No. 1). A total volume of 52.5 m 3 water was processed using the filter. At an average inlet turbidity of 5.6 nephelometric turbidity units (NTU), the outlet turbidity observed from the ECF was 1.6 NTU. A maximum flow rate (10 L . min -1 ) and applied potential of 18.0-20.0 V was found to yield an average turbidity-removal efficiency of ∝ 75 %. When the experiment was terminated, a throughput of > 2.08 . 10 5 NTU-liters was realized without any reduction in the removal efficiency. Removal of the internals of the filter showed that only the bottom 11 pairs of felts had brownish deposits, while the remaining felts looked clean and unused. (orig.)

  8. Use mobile pumps and liquid chilling water units to provide chilled water for nuclear reactor during nuclear power plant accident

    Zhang Guobin; Feng Jiaxuan

    2012-01-01

    From the nuclear accident in Japan Fuksuhima in March this year, despite a shut down of the reactor, the residue heat inside the reactor was not able to remove due to the failure of the cooling system and it finally caused the catastrophe. It was observed that when the failure of the cooling system after an earthquake of magnitude 9 and a tsunami of 28 meters height, the containment vessel for the reactor core was still able to maintain its integrity in the first 24 hours before the first explosion was happened. A backup emergency heat removal system for nuclear power plants using mo- bile pumps and liquid chilling units has been proposed 20 years ago by Cheung [Ref. 1]. Due to the fact that there are more than 400 nuclear power plants around the world and 10% of them are located in earthquake active zone, together with the aging of some of the power plants which were built more than 30 years ago, the risk of another nuclear accident becomes high. An emergency safety measure has to be designed in order to deal with the unforeseen scenario. This re- port re-visits the proposal again; to re-design to the suit the need and to integrate with the current situation of the nuclear industry. (authors)

  9. Widespread molecular detection of Legionella pneumophila Serogroup 1 in cold water taps across the United States

    In the United States 3,522 cases of legionellosis were reported to the Center for Disease Control and Prevention in 2009. Of these reports, it is estimated that 84% are caused by the microorganism Legionella pneumophila Serogroup (Sg) 1. Legionella spp. have been isolated and r...

  10. "The Waters of Meridiani" - Further Support for a Fluvial Interpretation of the Ridged, Layered Units

    Wilkinson, Justin; Kreslavsky, Misha

    2009-01-01

    A relatively unknown terrestrial fluvial environment, the mesoscale megafan, provides analogs for various Martian landscapes, including the etched unit (etched unit, Unite E of Arvidson et al., 2003; ridge-forming unit R of Edgett, 2005) of the Sinus Meridiani region on Mars. A global survey of Earth shows that megafans are very large partial cones of dominantly fluvial sediment with radii on the order of hundreds of km, and very low slopes. Responsible fluvial processes are sufficiently different from those of classical arid alluvial fans and deltas that it is useful to class megafans as separate features. The megafan model calls into question two commonly held ideas. 1. Earth examples prove that topographic basins per se are unnecessary for the accumulation of large sedimentary bodies. 2. River channels are by no means restricted to valleys (Meridiani sediments are termed a "valley-ed volume" of Edgett). These perspectives reveal unexpected parallels with features at Meridiani-several channel-like features that are widespread, mostly as ridges inverted by eolian erosion; channel networks covering thousands of sq km, especially on intercrater plains; and regional relationships of sediment bodies situated immediately downstream of highland masses. These all suggest that fluvial explanations are at least part of the Meridiani story.

  11. Development of the heavy-water organic-cooled reactor. Status report from the United States of America

    Trilling, C A [Atomics International, Division of North American Aviation, Inc., Canoga Park, CA (United States)

    1967-01-01

    In late 1964 the United States Atomic Energy Commission decided to undertake the development of the heavy-water-moderated nuclear power reactor as part of its overall programme for the development of advanced converter reactors. The inclusion of the heavy-water reactor concept was based on its indicated potential for achieving: efficient utilization of available fuel resources; generation of low cost electric power; feasibility of scale-up to very large single unit plant sizes for the dual purpose of generating power and desalting sea water. The excellent neutron economy inherent in heavy-water moderation allows a significant increase in the amount of power which can be generated from a given amount of ore. If one takes into account the amount of uranium required not only for burn-up but also to inventory new reactors in a rapidly expanding nuclear economy, heavy-water reactors show the potential of extracting one and a half to two times more power from the ore mined than light-water reactors. Such an improvement in dynamic fuel utilization will postpone the depletion of low cost uranium ore reserves, providing more time for the discovery of new ore resources and the development of economic fast breeder reactors. The excellent neutron economy of the heavy-water reactor also allows the achievement of appreciable burn-up with low enrichment fuel, with consequent low fuel cycle costs and therefore low energy generation costs. These low fuel cycle costs make the economics of this type of reactor rather insensitive to rising ore costs. They also make the concept well suited for the most economic production of the large quantities of heat required for water desalination. The use of individual pressure tubes for circulating the coolant through the reactor vessel lends itself to the development of a modular type design, which can be scaled up to very large single unit plant sizes by simply increasing the number of identical pressure tube modules and the number of coolant

  12. Vulnerability of shallow groundwater and drinking-water wells to nitrate in the United States

    Nolan, Bernard T.; Hitt, Kerie J.

    2006-01-01

    Two nonlinear models were developed at the national scale to (1) predict contamination of shallow ground water (typically drinking. The new models have several advantages over previous national-scale approaches. First, they predict nitrate concentration (rather than probability of occurrence), which can be directly compared with water-quality criteria. Second, the models share a mechanistic structure that segregates nitrogen (N) sources and physical factors that enhance or restrict nitrate transport and accumulation in ground water. Finally, data were spatially averaged to minimize small-scale variability so that the large-scale influences of N loading, climate, and aquifer characteristics could more readily be identified. Results indicate that areas with high N application, high water input, well-drained soils, fractured rocks or those with high effective porosity, and lack of attenuation processes have the highest predicted nitrate concentration. The shallow groundwater model (mean square error or MSE = 2.96) yielded a coefficient of determination (R2) of 0.801, indicating that much of the variation in nitrate concentration is explained by the model. Moderate to severe nitrate contamination is predicted to occur in the High Plains, northern Midwest, and selected other areas. The drinking-water model performed comparably (MSE = 2.00, R2 = 0.767) and predicts that the number of users on private wells and residing in moderately contaminated areas (>5 to ≤10 mg/L nitrate) decreases by 12% when simulation depth increases from 10 to 50 m.

  13. Growth and Identification of Bacteria in N-Halamine Dental Unit Waterline Tubing Using an Ultrapure Water Source

    Porteous, Nuala; Luo, Jie; Hererra, Monica; Schoolfield, John; Sun, Yuyu

    2011-01-01

    This study examined bacterial growth and type on biofilm-controlling dental unit waterline (DUWL) tubing (T) and control manufacturer's tubing (C) in a laboratory DUWL model using ultrapure source water that was cycled through the lines. Sections of tubing lines were detached and examined for biofilm growth using SEM imaging at six sampling periods. Bacteria from inside surfaces of T and C, source unit, and reservoir were cultured and enumerated. At six months, organisms were molecularly identified from the alignment matches obtained from the top three BLAST searches for the 16S region. There was a 1–3 log increase in organism growth in a clean, nonsterile reservoir within an hour. Biofilm was established on the inside surfaces of C within three weeks, but not on T. Proteobacteria, and Sphingomonas spp. were identified in the source reservoir and C line, and a variation of the genera was found in T line. PMID:22220171

  14. Environmental setting and factors that affect water quality in the Georgia-Florida Coastal Plain study unit

    Berndt, M.P.; Oaksford, E.T.; Darst, M.R.; Marella, R.L.

    1996-01-01

    The Georgia-Florida Coastal Plain study unit covers an area of nearly 62,000 square miles in the southeastern United States, mostly in the Coastal Plain physiographic province. Land resource provinces have been designated based on generalized soil classifications. Land resource provinces in the study area include: the Coastal Flatwoods, the Southern Coastal Plain, the Central Florida Ridge, the Sand Hills, and the Southern Piedmont. The study area includes all or parts of seven hydrologic subregions: the Ogeechee-Savannah, the Altamaha- St.Marys, the Suwannee, the Ochlockonee, the St. Johns, the Peace-Tampa Bay, and the Southern Florida. The primary source of water for public supply in the study area is ground water from the Upper Floridan aquifer. In 1990, more than 90 percent of the 2,888 million gallons per day of ground water used came from this aquifer. The population of the study area was 9.3 million in 1990. The cities of Jacksonville, Orlando, St. Petersburg, Tallahassee, and Tampa, Florida, and parts of Atlanta and Savannah, Georgia, are located in the study area. Forest and agricultural areas are the most common land uses in the study area, accounting for 48 percent and 25 percent of the study area, respectively. Climatic conditions range from temperate in Atlanta, Georgia, where mean annual temperature is about 61.3 degrees Fahrenheit, to subtropical in Tampa, Florida, where mean annual temperature is about 72.4 degrees Fahrenheit. Long-term average precipitation (1961-90) ranges from 43.9 inches per year in Tampa, Florida, and 44.6 in Macon, Georgia, to 65.7 inches per year in Tallahassee, Florida. Floods in the study area result from frontal systems, hurricanes, tropical storms, or severe thunderstorms. Droughts are not common in the study area,especially in the Florida part of the study area due to extensive maritime exposure. The primary physical and cultural characteristics in the study area include physiography, soils and land resource provinces

  15. Use of recombinant purified protein derivative (PPD) antigens as specific skin test for tuberculosis.

    Stavri, Henriette; Bucurenci, Nadia; Ulea, Irina; Costache, Adriana; Popa, Loredana; Popa, Mircea Ioan

    2012-11-01

    Purified protein derivative (PPD) is currently the only available skin test reagent used worldwide for the diagnosis of tuberculosis (TB). The aim of this study was to develop a Mycobacterium tuberculosis specific skin test reagent, without false positive results due to Bacillus Calmette-Guerin (BCG) vaccination using recombinant antigens. Proteins in PPD IC-65 were analyzed by tandem mass spectrometry and compared to proteins in M. tuberculosis culture filtrate; 54 proteins were found in common. Top candidates MPT64, ESAT 6, and CFP 10 were overexpressed in Escherichia coli expression strains and purified as recombinant proteins. To formulate optimal immunodiagnostic PPD cocktails, the antigens were evaluated by skin testing guinea pigs sensitized with M. tuberculosis H37Rv and BCG. For single antigens and a cocktail mixture of these antigens, best results were obtained using 3 μg/0.1 ml, equivalent to 105 TU (tuberculin units). Each animal was simultaneously tested with PPD IC-65, 2 TU/0.1 ml, as reference. Reactivity of the multi-antigen cocktail was greater than that of any single antigen. The skin test results were between 34.3 and 76.6 per cent the level of reactivity compared to that of the reference when single antigens were tested and 124 per cent the level of reactivity compared to the reference for the multi-antigen cocktail. Our results showed that this specific cocktail could represent a potential candidate for a new skin diagnostic test for TB.

  16. PROFILE OF PLASTIC WATER BOTTLES WASTES PROCESSING BUSINESS UNIT FOR WASTE PICKERS

    Herijanto P.

    2017-09-01

    Full Text Available Used plastic water bottles waste pickers can be categorized as one of the informal sector’s component. They work for themselves by picking up used water bottles and selling them to the waste collectors. The problem to be solved in this research is How the Most Appropriate Used Plastic Water Bottles Business Model for Waste Pickers Is that enables them to be categorized as formal sector. From the result of the interview with 120 waste pickers, 96 results were qualified to be analyzed. The interview was located in several waste collectors, which were visited by waste pickers at certain hours. The data were analyzed descriptively based on six business aspects. Specifically for production facilities, Quality Function Deployment (QFD and Value Engineering (VE analysis were performed. The results of the analysis indicate that the business is practicable for waste pickers and has the potential to enable them run a formal business sector.

  17. Influence of a highly purified senna extract on colonic epithelium.

    van Gorkom, B A; Karrenbeld, A; van Der Sluis, T; Koudstaal, J; de Vries, E G; Kleibeuker, J H

    2000-01-01

    Chronic use of sennoside laxatives often causes pseudomelanosis coli. A recent study suggested that pseudomelanosis coli is associated with an increased colorectal cancer risk. A single high dose of highly purified senna extract increased proliferation rate and reduced crypt length in the sigmoid colon compared to historical controls. To evaluate in a controlled study the effects of highly purified senna extract on cell proliferation and crypt length in the entire colon and on p53 and bcl-2 expression. Addition of a senna extract to colonic lavage was studied in 184 consecutive outpatients. From 32 randomised patients, 15 with sennosides (Sen), 17 without (NSen), biopsies were taken. Proliferative activity was studied in 4 areas of the colon, using 5-bromo-2'-deoxyuridine labelling and immunohistochemistry (labelling index, LI). Expression of p53 and bcl-2 in the sigmoid colon was determined immunohistochemically. Crypts were shorter in Sen than in NSen in the transverse and sigmoid colon. LI was higher in Sen than in NSen in the entire colon. No difference in p53 expression was seen. Bcl-2 expression was higher in both groups when crypts were shorter and/or proliferation was increased. Sennosides induce acute massive cell loss probably by apoptosis, causing shorter crypts, and increased cell proliferation and inhibition of apoptosis to restore cellularity. These effects may reflect the mechanism for the suggested cancer-promoting effect of chronic sennoside use. Copyright 2000 S. Karger AG, Basel

  18. Activation of purified calcium channels by stoichiometric protein phosphorylation

    Nunoki, K.; Florio, V.; Catterall, W.A. (Univ. of Washington, Seattle (USA))

    1989-09-01

    Purified dihydropyridine-sensitive calcium channels from rabbit skeletal muscle were reconstituted into phosphatidylcholine vesicles to evaluate the effect of phosphorylation by cyclic AMP-dependent protein kinase (PK-A) on their function. Both the rate and extent of {sup 45}Ca{sup 2+} uptake into vesicles containing reconstituted calcium channels were increased severalfold after incubation with ATP and PK-A. The degree of stimulation of {sup 45}Ca{sup 2+} uptake was linearly proportional to the extent of phosphorylation of the alpha 1 and beta subunits of the calcium channel up to a stoichiometry of approximately 1 mol of phosphate incorporated into each subunit. The calcium channels activated by phosphorylation were determined to be incorporated into the reconstituted vesicles in the inside-out orientation and were completely inhibited by low concentrations of dihydropyridines, phenylalkylamines, Cd{sup 2+}, Ni{sup 2+}, and Mg{sup 2+}. The results demonstrate a direct relationship between PK-A-catalyzed phosphorylation of the alpha 1 and beta subunits of the purified calcium channel and activation of the ion conductance activity of the dihydropyridine-sensitive calcium channels.

  19. Activation of purified calcium channels by stoichiometric protein phosphorylation

    Nunoki, K.; Florio, V.; Catterall, W.A.

    1989-01-01

    Purified dihydropyridine-sensitive calcium channels from rabbit skeletal muscle were reconstituted into phosphatidylcholine vesicles to evaluate the effect of phosphorylation by cyclic AMP-dependent protein kinase (PK-A) on their function. Both the rate and extent of 45 Ca 2+ uptake into vesicles containing reconstituted calcium channels were increased severalfold after incubation with ATP and PK-A. The degree of stimulation of 45 Ca 2+ uptake was linearly proportional to the extent of phosphorylation of the alpha 1 and beta subunits of the calcium channel up to a stoichiometry of approximately 1 mol of phosphate incorporated into each subunit. The calcium channels activated by phosphorylation were determined to be incorporated into the reconstituted vesicles in the inside-out orientation and were completely inhibited by low concentrations of dihydropyridines, phenylalkylamines, Cd 2+ , Ni 2+ , and Mg 2+ . The results demonstrate a direct relationship between PK-A-catalyzed phosphorylation of the alpha 1 and beta subunits of the purified calcium channel and activation of the ion conductance activity of the dihydropyridine-sensitive calcium channels

  20. Creating and purifying an observation instrument using the generalizability theory

    Elena Rodríguez-Naveiras

    2013-12-01

    Full Text Available The control of quality of data it is one of the most relevant aspects in observational researches. The Generalizability Theory (GT provides a method of analysis that allows us to isolate the various sources of error measurement. At the same time, it helps us to determine the extent to which various factors can change and analyze the effect on the generalizability coefficient. In the work shown here, there are two studies aimed to creating and purifying an observation instrument, Observation Protocol in the Teaching Functions (Protocolo de Funciones Docentes, PROFUNDO, v1 and v2, for behavioral assessment which has been carried out by instructors in a social-affective out-of-school program. The reliability and homogeneity studies are carried out once the instrument has been created and purified. The reliability study will be done through the GT method taking both codes (c and agents (a as differential facets in. The generalization will be done through observers using a crossed multi-faceted design (A × O × C. In the homogeneity study the generalization facet will be done through codes using the same design that the reliability study.

  1. Surface plasmon resonance sensing: from purified biomolecules to intact cells.

    Su, Yu-Wen; Wang, Wei

    2018-04-12

    Surface plasmon resonance (SPR) has become a well-recognized label-free technique for measuring the binding kinetics between biomolecules since the invention of the first SPR-based immunosensor in 1980s. The most popular and traditional format for SPR analysis is to monitor the real-time optical signals when a solution containing ligand molecules is flowing over a sensor substrate functionalized with purified receptor molecules. In recent years, rapid development of several kinds of SPR imaging techniques have allowed for mapping the dynamic distribution of local mass density within single living cells with high spatial and temporal resolutions and reliable sensitivity. Such capability immediately enabled one to investigate the interaction between important biomolecules and intact cells in a label-free, quantitative, and single cell manner, leading to an exciting new trend of cell-based SPR bioanalysis. In this Trend Article, we first describe the principle and technical features of two types of SPR imaging techniques based on prism and objective, respectively. Then we survey the intact cell-based applications in both fundamental cell biology and drug discovery. We conclude the article with comments and perspectives on the future developments. Graphical abstract Recent developments in surface plasmon resonance (SPR) imaging techniques allow for label-free mapping the mass-distribution within single living cells, leading to great expansions in biomolecular interactions studies from homogeneous substrates functionalized with purified biomolecules to heterogeneous substrates containing individual living cells.

  2. Tektite-bearing, deep-water clastic unit at the Cretaceous-Tertiary boundary in northeastern Mexico

    Smit, J.; Montanari, A.; Swinburne, N. H.; Alvarez, W.; Hildebrand, A. R.; Margolis, S. V.; Claeys, P.; Lowrie, W.; Asaro, F.

    1992-01-01

    The hypothesis of Cretaceous-Tertiary (K-T) boundary impact on Yucatan, Mexico, predicts that nearby sites should show evidence of proximal impact ejecta and disturbance by giant waves. An outcrop along the Arroyo el Mimbral in northeastern Mexico contains a layered clastic unit up to 3 m thick that interrupts a biostratigraphically complete pelagic-marl sequence deposited at more than 400 m water depth. The marls were found to be unsuitable for determining magnetostratigraphy, but foraminiferal biostratigraphy places the clastic unit precisely at the K-T boundary. We interpret this clastic unit as the deposit of a megawave or tsunami produced by an extraterrestrial impact. The clastic unit comprises three main subunits. (1) The basal "spherule bed" contains glass in the form of tektites and microtektites, glass spherules replaced by chlorite-smectite and calcite, and quartz grains showing probable shock features. This bed is interpreted as a channelized deposit of proximal ejecta. (2) A set of lenticular, massive, graded "laminated beds" contains intraclasts and abundant plant debris, and may be the result of megawave backwash that carried coarse debris from shallow parts of the continental margin into deeper water. (3) At the top, several thin "ripple beds" composed of fine sand are separated by clay drapes; they are interpreted as deposits of oscillating currents, perhaps a seiche. An iridium anomaly (921 +/- 23 pg/g) is observed at the top of the ripple beds. Our observations at the Mimbral locality support the hypothesis of a K-T impact on nearby Yucatan.

  3. Quantifying Organic Matter in Surface Waters of the United States and Delivery to the Coastal Zone

    Boyer, E. W.; Alexander, R. B.; Smith, R. A.; Shih, J.

    2012-12-01

    Organic carbon (OC) is a critical water quality characteristic in surface waters. It is an important component of the energy balance and food chains in freshwater and estuarine aquatic ecosystems, is significant in the mobilization and transport of contaminants along flow paths, and is associated with the formation of known carcinogens in drinking water supplies. The importance of OC dynamics on water quality has been recognized, but challenges remain in quantitatively addressing processes controlling OC fluxes over broad spatial scales in a hydrological context, and considering upstream-downstream linkages along flow paths. Here, we: 1) quantified lateral OC fluxes in rivers, streams, and reservoirs across the nation from headwaters to the coasts; 2) partitioned how much organic carbon that is stored in lakes, rivers and streams comes from allochthonous sources (produced in the terrestrial landscape) versus autochthonous sources (produced in-stream by primary production); 3) estimated the delivery of dissolved and total forms of organic carbon to coastal estuaries and embayments; and 4) considered seasonal factors affecting the temporal variation in OC responses. To accomplish this, we developed national-scale models of organic carbon in U.S. surface waters using the spatially referenced regression on watersheds (SPARROW) technique. The modeling approach uses mechanistic formulations, imposes mass balance constraints, and provides a formal parameter estimation structure to statistically estimate sources and fate of OC in terrestrial and aquatic ecosystems. We calibrated and evaluated the model with statistical estimates of OC loads that were observed at a network of monitoring stations across the nation, and further explored factors controlling seasonal dynamics of OC based on these long term monitoring data. Our results illustrate spatial patterns and magnitudes OC loadings in rivers, highlighting hot spots and suggesting origins of the OC to each location

  4. [Investigation on the process of sapindus saponin purified with macroporous adsorption resin and screening of its bacteriostasis].

    Fu, Yong; Lei, Peng; Han, Yu-mei; Yan, Dan

    2010-02-01

    To study the technological parameters of the purification process of saponins with macroporous adsorption resin. The adsorptive characteristics and elutive parameters of the process were studied by taking the elutive and purified ratio of saponins as markers. Bacteriostasis activity of each parts eluted was evaluated by the mean of cup-plate method. 13.6 mL of the extraction of sapindus saponin (crude drugs 0.01 g/mL) was purified with a column of macroporous adsorption resin (phi15 mm x H90 mm, dry weight 2.5 g) and washed with 3BV of distilled water, then eluted with 3BV of 30% ethanol and 3BV of 70% ethanol, most of saponins were collected in the 70% ethanol. With macroporous adsorption resin adsorbing and purifying, the elutive ratio of saponins was 93.8% and the purity reached 250.1%. So this process of applying macroporous adsorption resin to adsorb and purify saponins is feasible, and supplies reference to the purification of other types of saponin.

  5. Some stream waters of the Western United States, with chapters on sediment carried by the Rio Grande and the industrial application of water analyses

    Stabler, Herman

    1911-01-01

    A systematic study of the waters likely to be utilized on the Reclamation Service projects was made in order to determine the influence of the salinity of the waters on the growth of vegetation and the effect of suspended matter in silting canals and reservoirs. The work was begun early in 1905, under the direction of Thomas H. Means, engineer, and was continued during 1906 and until May, 1907, under the direction of W. H. Heileman, engineer. The analyses were made in a laboratory established at quarters provided by the University of California at Berkeley, Cal., by C. H. Stone, P. L. McCreary, F. M. Eaton, O. J. Hawley, W. C. Riddell, F. T. Berry, H. A. Burns, J. H. Hampson, J. A. Pearce, and M. Vaygouny, the greater part of the work being that of the first five named. C. H. Stone was chemist in charge at the beginning of the investigations and is chiefly responsible for the plan of the analytical work and the methods of analysis.The results of the investigations were prepared for publication under instructions from F. H. Newell, Director of the United States Reclamation Service, by Herman Stabler, assistant engineer, who assembled and checked- the analyses, compiled the accompanying stream-flow data from records of the United States Geological Survey, and computed daily discharge of suspended matter and dissolved solids, under the supervision of D. W. Murphy, engineer in charge of Washington office engineering.

  6. International Space Station United States Laboratory Module Water Recovery Management Subsystem Verification from Flight 5A to Stage ULF2

    Williams, David E.; Labuda, Laura

    2009-01-01

    The International Space Station (ISS) Environmental Control and Life Support (ECLS) system comprises of seven subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), Vacuum System (VS), Water Recovery and Management (WRM), and Waste Management (WM). This paper provides a summary of the nominal operation of the United States (U.S.) Laboratory Module WRM design and detailed element methodologies utilized during the Qualification phase of the U.S. Laboratory Module prior to launch and the Qualification of all of the modification kits added to it from Flight 5A up and including Stage ULF2.

  7. Memorandum of Understanding on Surface Coal Mining Operations Resulting in Placement of Excess Spoil Fills in the Waters of the United States

    MOU on Surface Coal Mining Operations establishes a process for improving coordination in the review of permit applications required for surface coal mining and reclamation in waters of the United States

  8. Impacts of urbanization on stream water quantity and quality in the United States

    Ge Sun; Peter Caldwell

    2015-01-01

    Since the 1950s, the world’s urban population has grown more than 400% to 3.9 billion today. About 60% of the total population is expected to live in urban areas by the year 2025. For the United States (U.S.), 80% of the population lives in urban areas. The Earth has entered into the Anthropocene, a new geological epoch dominated by urbanization and people.

  9. Use of LiDAR to Assist in Delineating Waters of the United States, Including Wetlands

    2014-03-01

    components: a mounting platform, a laser and scanning mirror, an inertial measurement unit (IMU), a global positioning system (GPS) antenna and...including but not limited to TIFF, ASC , IMG, and KML files or compressed as a KMZ file. These files are quickly imported and viewed using GIS such as...sediment transport processes and hydraulics. Sedimentology 56:2024–2043. Hogg, A., and J. Holland. 2008. An evaluation of DEMs derived from LiDAR

  10. 76 FR 29191 - Purified Carboxymethylcellulose From Finland and the Netherlands: Continuation of Antidumping...

    2011-05-20

    ... Carboxymethylcellulose From Finland and the Netherlands: Continuation of Antidumping Duty Orders AGENCY: Import... antidumping duty orders on purified carboxymethylcellulose from Finland and the Netherlands would likely lead...) from Finland and the Netherlands. See Notice of Antidumping Duty Orders: Purified...

  11. Control of water infiltration into near-surface, low-level waste-disposal units in humid regions

    O'Donnell, E.; Ridky, R.W.; Schulz, R.K.

    1994-01-01

    This study's objective is to assess means for controlling water infiltration through waste-disposal unit covers in humid regions. Experimental work is being performed in large-scale lysimeters (75 ft x 45 ft x 10 ft) at Beltsville, Maryland. Results of the assessment are applicable to disposal of low-level radioactive waste (LLW), uranium mill tailings, hazardous waste, and sanitary landfills. Three kinds of waste-disposal unit covers or barriers to water infiltration are being investigated: (1) resistive layer barrier, (2) conductive layer barrier, and (3) bioengineering management. The resistive layer barrier consists of compacted earthen material (e.g., clay). The conductive layer barrier consists of a conductive layer in conjunction with a capillary break. As long as unsaturated flow conditions are maintained, the conductive layer will wick water around the capillary break. Below-grade layered covers such as (1) and (2) will fail if there is appreciable subsidence of the cover, and remedial action for this kind of failure will be difficult. A surface cover, called bioengineering management, is meant to overcome this problem. The bioengineering management surface barrier is easily repairable if damaged by subsidence; therefore, it could be the system of choice under active subsidence conditions. The bioengineering management procedure also has been shown to be effective in dewatering saturated trenches and could be used for remedial action efforts. After cessation of subsidence, that procedure could be replaced by a resistive layer barrier or, perhaps even better, by a resistive layer barrier/conductive layer barrier system. The latter system would then give long-term effective protection against water entry into waste without institutional care

  12. Pentacene field-effect transistors by in situ and real time electrical characterization: Comparison between purified and non-purified thin films

    Liu, Shun-Wei; Wen, Je-Min; Lee, Chih-Chien; Su, Wei-Cheng; Wang, Wei-Lun; Chen, Ho-Chien; Lin, Chun-Feng

    2013-01-01

    We present an electrical characterization of the organic field-effect transistor with purified and non-purified pentacene by using in situ and real time measurements. The field-effect phenomenon was observed at the thickness of 1.5 nm (approximately one monolayer of pentacene) for purified pentacene, as compared to 3.0 nm for the non-purified counterpart. Moreover, the hole mobility is improved from 0.13 to 0.23 cm 2 /V s after the sublimation process to purify the pentacene. With atomic force microscopic measurements, the purified pentacene thin film exhibits a larger grain size and film coverage, resulting in better crystallinity of the thin film structure due to the absence of the impurities. This is further confirmed by X-ray diffraction patterns, which show higher intensities for the purified pentacene. - Highlights: • We present in-situ characterization for pentacene field-effect transistors. • The hole mobility is improved after the sublimation process to purify the pentacene. • Purified pentacene thin film exhibits a larger grain size and film coverage. • Hole mobility of pentacene is improved from 0.13 to 0.23 cm 2 /V s. • The discontinuity of grain boundary may cause the shift of threshold voltage

  13. Pentacene field-effect transistors by in situ and real time electrical characterization: Comparison between purified and non-purified thin films

    Liu, Shun-Wei, E-mail: swliu@mail.mcut.edu.tw [Department of Electronic Engineering, Ming Chi University of Technology, New Taipei City 24301, Taiwan, ROC (China); Wen, Je-Min; Lee, Chih-Chien; Su, Wei-Cheng; Wang, Wei-Lun; Chen, Ho-Chien [Department of Electronic Engineering, National Taiwan University of Science and Technology, Taipei, 10607 Taiwan, ROC (China); Lin, Chun-Feng [Department of Electronic Engineering, Ming Chi University of Technology, New Taipei City 24301, Taiwan, ROC (China)

    2013-05-01

    We present an electrical characterization of the organic field-effect transistor with purified and non-purified pentacene by using in situ and real time measurements. The field-effect phenomenon was observed at the thickness of 1.5 nm (approximately one monolayer of pentacene) for purified pentacene, as compared to 3.0 nm for the non-purified counterpart. Moreover, the hole mobility is improved from 0.13 to 0.23 cm{sup 2}/V s after the sublimation process to purify the pentacene. With atomic force microscopic measurements, the purified pentacene thin film exhibits a larger grain size and film coverage, resulting in better crystallinity of the thin film structure due to the absence of the impurities. This is further confirmed by X-ray diffraction patterns, which show higher intensities for the purified pentacene. - Highlights: • We present in-situ characterization for pentacene field-effect transistors. • The hole mobility is improved after the sublimation process to purify the pentacene. • Purified pentacene thin film exhibits a larger grain size and film coverage. • Hole mobility of pentacene is improved from 0.13 to 0.23 cm{sup 2}/V s. • The discontinuity of grain boundary may cause the shift of threshold voltage.

  14. Outbreaks Associated with Treated Recreational Water - United States, 2000-2014.

    Hlavsa, Michele C; Cikesh, Bryanna L; Roberts, Virginia A; Kahler, Amy M; Vigar, Marissa; Hilborn, Elizabeth D; Wade, Timothy J; Roellig, Dawn M; Murphy, Jennifer L; Xiao, Lihua; Yates, Kirsten M; Kunz, Jasen M; Arduino, Matthew J; Reddy, Sujan C; Fullerton, Kathleen E; Cooley, Laura A; Beach, Michael J; Hill, Vincent R; Yoder, Jonathan S

    2018-05-18

    Outbreaks associated with exposure to treated recreational water can be caused by pathogens or chemicals in venues such as pools, hot tubs/spas, and interactive water play venues (i.e., water playgrounds). During 2000-2014, public health officials from 46 states and Puerto Rico reported 493 outbreaks associated with treated recreational water. These outbreaks resulted in at least 27,219 cases and eight deaths. Among the 363 outbreaks with a confirmed infectious etiology, 212 (58%) were caused by Cryptosporidium (which causes predominantly gastrointestinal illness), 57 (16%) by Legionella (which causes Legionnaires' disease, a severe pneumonia, and Pontiac fever, a milder illness with flu-like symptoms), and 47 (13%) by Pseudomonas (which causes folliculitis ["hot tub rash"] and otitis externa ["swimmers' ear"]). Investigations of the 363 outbreaks identified 24,453 cases; 21,766 (89%) were caused by Cryptosporidium, 920 (4%) by Pseudomonas, and 624 (3%) by Legionella. At least six of the eight reported deaths occurred in persons affected by outbreaks caused by Legionella. Hotels were the leading setting, associated with 157 (32%) of the 493 outbreaks. Overall, the outbreaks had a bimodal temporal distribution: 275 (56%) outbreaks started during June-August and 46 (9%) in March. Assessment of trends in the annual counts of outbreaks caused by Cryptosporidium, Legionella, or Pseudomonas indicate mixed progress in preventing transmission. Pathogens able to evade chlorine inactivation have become leading outbreak etiologies. The consequent outbreak and case counts and mortality underscore the utility of CDC's Model Aquatic Health Code (https://www.cdc.gov/mahc) to prevent outbreaks associated with treated recreational water.

  15. The United Kingdom Acid Waters Monitoring Network: a review of the first 15 years and introduction to the special issue

    Monteith, D.T.; Evans, C.D.

    2005-01-01

    The United Kingdom Acid Waters Monitoring Network (AWMN) was established in 1988 to determine the ecological impact of acidic emissions control policy on acid-sensitive lakes and streams. AWMN data have been used to explore a range of causal linkages necessary to connect changes in emissions to chemical and, ultimately, biological recovery. Regional scale reductions in sulphur (S) deposition have been found to have had an immediate influence on surface water chemistry, including increases in acid neutralising capacity, pH and alkalinity and declines in aluminium toxicity. These in turn can be linked to changes in the aquatic biota which are consistent with 'recovery' responses. A continuation of the current programme is essential in order to better understand apparent non-linearity between nitrogen (N) in deposition and runoff, the substantial rise in organic acid concentrations, and the likely impacts of forecast climate change and other potential constraints on further biological improvement. - After 15 years of the UK Acid Waters Monitoring Network, we can now draw clear conclusions regarding the impact of emission reductions on acidified UK fresh waters

  16. Sup(239,240)Pu in estuarine and shelf waters of the north-eastern United States

    Sholkovitz, E.R.; Mann, D.R.

    1987-01-01

    The distribution of sup(239,240)Pu between dissolved and particulate forms has been measured in four estuaries on the north-east coast of the United States (Connecticut River, Delaware Bay, Chesapeake Bay, and Mullica River). The data cover the whole salinity range from freshwater input to shelf waters at 3.5% and includes one profile from a nearly anoxic basin in the Chesapeake Bay. In the organic-rich Mullica River estuary, large-scale removal of riverine dissolved sup(239,240)Pu occurs at low salinities due to salt-induced coagulation, a mechanism analogous to that for iron and humic acids. Within the 0 to 2.5-3.5% zone in the other three estuaries, the activity of dissolved sup(239,240)Pu increases almost conservatively. The activities of particulate sup(239,240)Pu are highest in the more turbid waters of low salinity regime (0-1.5%), but become increasingly insignificant with respect to dissolved sup(239,240)Pu as salinities increase. At higher salinities corresponding to shelf water, there is a sharp increase in dissolved sup(239,240)Pu activity. The dissolved sup(239,240)Pu activity within each estuary appears to be inversely related to the flushing time of water. The sharp decrease in dissolved sup(239,240)Pu activities between shelf and estuarine waters appears to be driven by removal within the estuaries themselves rather than on the shelf. Dissolved sup(239,240)Pu activities are lower in the nearly-anoxic bottom waters of Chesapeake Bay indicating enhanced removal by redox transformation of Pu [i.e., Pu(V) to Pu(IV)]. (author)

  17. Occurrence of sulfonylurea, sulfonamide, imidazolinone, and other herbicides in rivers, reservoirs and ground water in the Midwestern United States, 1998

    Battaglin, W.A.; Furlong, E.T.; Burkhardt, M.R.; Peter, C.J.

    2000-01-01

    Sulfonylurea (SU), sulfonamide (SA), and imidazolinone (IMI) herbicides are relatively new classes of chemical compounds that function by inhibiting the action of a plant enzyme, stopping plant growth, and eventually killing the plant. These compounds generally have low mammalian toxicity, but plants demonstrate a wide range in sensitivity to SUs, SAs, and IMIs with over a 10000-fold difference in observed toxicity levels for some compounds. SUs, SAs, and IMIs are applied either pre- or post-emergence to crops commonly at 1/50th or less of the rate of other herbicides. Little is known about their occurrence, fate, or transport in surface water or ground water in the USA. To obtain information on the occurrence of SU, SA, and IMI herbicides in the Midwestern United States, 212 water samples were collected from 75 surface-water and 25 ground-water sites in 1998. These samples were analyzed for 16 SU, SA and IMI herbicides by USGS Methods Research and Development Program staff using high-performance liquid chromatography/mass spectrometry. Samples were also analyzed for 47 pesticides or pesticide degradation products. At least one of the 16 SUs, SAs or IMIs was detected above the method reporting limit (MRL) of 0.01 ??g/l in 83% of 130 stream samples. Imazethapyr was detected most frequently (71% of samples) followed by flumetsulam (63% of samples) and nicosulfuron (52% of samples). The sum of SU, SA and IMI concentrations exceeded 0.5 ??g/l in less than 10% of stream samples. Acetochlor, alachlor, atrazine, cyanazine and metolachlor were all detected in 90% or more of 129 stream samples. The sum of the concentration of these five herbicides exceeded 50 ??g/l in approximately 10% of stream samples. At least one SU, SA, or IMI herbicide was detected above the MRL in 24% of 25 ground-water samples and 86% of seven reservoir samples. Copyright (C) 2000 Elsevier Science B.V.

  18. Removal of waterborne pathogens from liver transplant unit water taps in prevention of healthcare-associated infections: a proposal for a cost-effective, proactive infection control strategy.

    Zhou, Z Y; Hu, B J; Qin, L; Lin, Y E; Watanabe, H; Zhou, Q; Gao, X D

    2014-04-01

    Hospital water supplies often contain waterborne pathogens, which can become a reservoir for healthcare-associated infections (HAIs). We surveyed the extent of waterborne pathogen contamination in the water supply of a Liver Transplant Unit. The efficacy of point-of-use (POU) water filters was evaluated by comparative analysis in routine clinical use. Our baseline environmental surveillance showed that Legionella spp. (28%, 38/136), Pseudomonas aeruginosa (8%, 11/136), Mycobacterium spp. (87%, 118/136) and filamentous fungi (50%, 68/136) were isolated from the tap water of the Liver Transplant Unit. 28.9% of Legionella spp.-positive water samples (n = 38) showed high-level Legionella contamination (≥10(3) CFU/L). After installation of the POU water filter, none of these pathogens were found in the POU filtered water samples. Furthermore, colonizations/infections with Gram-negative bacteria determined from patient specimens were reduced by 47% during this period, even if only 27% (3/11) of the distal sites were installed with POU water filters. In conclusion, the presence of waterborne pathogens was common in the water supply of our Liver Transplant Unit. POU water filters effectively eradicated these pathogens from the water supply. Concomitantly, healthcare-associated colonization/infections declined after the POU filters were installed, indicating their potential benefit in reducing waterborne HAIs. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  19. Hydrochemical Regions of the Glacial Aquifer System, Northern United States, and Their Environmental and Water-Quality Characteristics

    Arnold, Terri L.; Warner, Kelly L.; Groschen, George E.; Caldwell, James P.; Kalkhoff, Stephen J.

    2008-01-01

    The glacial aquifer system in the United States is a large (953,000 square miles) regional aquifer system of heterogeneous composition. As described in this report, the glacial aquifer system includes all unconsolidated geologic material above bedrock that lies on or north of the line of maximum glacial advance within the United States. Examining ground-water quality on a regional scale indicates that variations in the concentrations of major and minor ions and some trace elements most likely are the result of natural variations in the geologic and physical environment. Study of the glacial aquifer system was designed around a regional framework based on the assumption that two primary characteristics of the aquifer system can affect water quality: intrinsic susceptibility (hydraulic properties) and vulnerability (geochemical properties). The hydrochemical regions described in this report were developed to identify and explain regional spatial variations in ground-water quality in the glacial aquifer system within the hypothetical framework context. Data analyzed for this study were collected from 1991 to 2003 at 1,716 wells open to the glacial aquifer system. Cluster analysis was used to group wells with similar ground-water concentrations of calcium, chloride, fluoride, magnesium, potassium, sodium, sulfate, and bicarbonate into five unique groups. Maximum Likelihood Classification was used to make the extrapolation from clustered groups of wells, defined by points, to areas of similar water quality (hydrochemical regions) defined in a geospatial model. Spatial data that represented average annual precipitation, average annual temperature, land use, land-surface slope, vertical soil permeability, average soil clay content, texture of surficial deposits, type of surficial deposit, and potential for ground-water recharge were used in the Maximum Likelihood Classification to classify the areas so the characteristics of the hydrochemical regions would resemble the

  20. Measurement of Ozone Emission and Particle Removal Rates from Portable Air Purifiers

    Mang, Stephen A.; Walser, Maggie L.; Nizkorodov, Sergey A.; Laux, John M.

    2009-01-01

    Portable air purifiers are popular consumer items, especially in areas with poor air quality. Unfortunately, most users of these air purifiers have minimal understanding of the factors affecting their efficiency in typical indoor settings. Emission of the air pollutant ozone (O[subscript 3]) by certain air purifiers is of particular concern. In an…

  1. Survey of fish impingement at power plants in the United States. Volume II. Inland waters

    Freeman, R.F. III; Sharma, R.K.

    1977-03-01

    Impingement of fish at cooling-water intakes of 33 power plants located on inland waters other than the Great Lakes has been surveyed and data are presented. Descriptions of site, plant, and intake design and operation are provided. Reports in this volume summarize impingement data for individual plants in tabular and histogram formats. Information was available from differing sources such as the utilities themselves, public documents, regulatory agencies, and others. Thus, the extent of detail in the reports varies greatly from plant to plant. Histogram preparation involved an extrapolation procedure that has inadequacies. The reader is cautioned in the use of information presented in this volume to determine intake-design acceptability or intensity of impacts on ecosystems. No conclusions are presented herein; data comparisons are made in Volume IV

  2. Characterization and constructive utilization of sludge produced in clari-flocculation unit of water treatment plant

    Ahmad, Tarique; Ahmad, Kafeel; Alam, Mehtab

    2018-03-01

    All water treatment plants produce waste/residue amid the treatment of raw water. This study selectively investigates the clariflocculator sludge for its physicochemical characteristics and potential reuse options. Sieve analysis, XRF, SEM, XRD, FTIR, and TG-DTA instrumental techniques have been used to characterize the sludge sample. Results show that clariflocculator sludge contains about 78% fine sand having grain size range 150-75 μm. SiO2, Al2O3, Fe2O3 and CaO constitute the maximum percentage of chemical compounds present in the sludge and quartz is the main crystalline phase of the sludge. Recycling and reuse of this sludge, especially, as fine sand in preparing mortar, concrete mix and other civil engineering products would pave the way for constructive utilization with safe and sustainable sludge management strategies.

  3. A GPRS-Based Low Energy Consumption Remote Terminal Unit for Aquaculture Water Quality Monitoring

    Xu , Dan; Li , Daoliang; Fei , Biaoqing; Wang , Yang; Peng , Fa

    2013-01-01

    International audience; The monitoring of water quality parameters such as DO, pH, salinity and temperature are necessary for the health of seafood such as sea cucumber. However, traditional monitoring system is based on cable data acquisition that has many disadvantages. Nowadays, GPRS is the most commonly accepted way for wireless transmission. Based on it, a type of low energy consumption RTU is developed and applied. In this paper, details of the design are introduced. In hardware design ...

  4. Open hydrology courseware using the United States Geological Survey’s National Water Census Data Portal

    Nelson, Jake; Ames, Daniel P.; Blodgett, David L.

    2018-01-01

    The U.S. Geological Survey (USGS) is the primary U.S. Government agency for water data collection and dissemination. In this role, the USGS has recently created and deployed a National Water Census Data Portal (NWC-DP) which provides access to streamflow, evapotransporation, precipitation, aquatic biology and other data at the national level. Recognizing the value of these data sets for hydrologic science education, this paper presents an effort to bridge the gap between pencil–and-paper-based hydrology curriculum and the USGS NWC-DP resource. Specifically, we have developed an R package, National Water Census Education (NWCEd), and five associated laboratory exercises that integrate R- and web-services-based access to the NWC-DP data sets. Using custom functions built into the NWCEd, students are able to access unprecedented amounts of hydrologic data from the NWC-DP, which can be applied to current hydrology curriculum and analyzed using NWCEd and a number of other open-source R tools.

  5. Break-Even Cost for Residential Solar Water Heating in the United States: Key Drivers and Sensitivities

    Cassard, H.; Denholm, P.; Ong, S.

    2011-02-01

    This paper examines the break-even cost for residential rooftop solar water heating (SWH) technology, defined as the point where the cost of the energy saved with a SWH system equals the cost of a conventional heating fuel purchased from the grid (either electricity or natural gas). We examine the break-even cost for the largest 1,000 electric and natural gas utilities serving residential customers in the United States as of 2008. Currently, the break-even cost of SWH in the United States varies by more than a factor of five for both electricity and natural gas, despite a much smaller variation in the amount of energy saved by the systems (a factor of approximately one and a half). The break-even price for natural gas is lower than that for electricity due to a lower fuel cost. We also consider the relationship between SWH price and solar fraction and examine the key drivers behind break-even costs. Overall, the key drivers of the break-even cost of SWH are a combination of fuel price, local incentives, and technical factors including the solar resource location, system size, and hot water draw.

  6. Water

    ... www.girlshealth.gov/ Home Nutrition Nutrition basics Water Water Did you know that water makes up more ... to drink more water Other drinks How much water do you need? top Water is very important, ...

  7. The International Center for Integrated Water Resources Management (ICIWaRM): The United States' Contribution to UNESCO IHP's Global Network of Water Centers

    Logan, W. S.

    2015-12-01

    The concept of a "category 2 center"—i.e., one that is closely affiliated with UNESCO, but not legally part of UNESCO—dates back many decades. However, only in the last decade has the concept been fully developed. Within UNESCO, the International Hydrological Programme (IHP) has led the way in creating a network of regional and global water-related centers.ICIWaRM—the International Center for Integrated Water Resources Management—is one member of this network. Approved by UNESCO's General Conference, the center has been operating since 2009. It was designed to fill a niche in the system for a center that was backed by an institution with on-the-ground water management experience, but that also had strong connections to academia, NGOs and other governmental agencies. Thus, ICIWaRM is hosted by the US Army Corps of Engineers' Institute for Water Resources (IWR), but established with an internal network of partner institutions. Three main factors have contributed to any success that ICIWaRM has achieved in its global work: A focus on practical science and technology which can be readily transferred. This includes the Corps' own methodologies and models for planning and water management, and those of our university and government partners. Collaboration with other UNESCO Centers on joint applied research, capacity-building and training. A network of centers needs to function as a network, and ICIWaRM has worked together with UNESCO-affiliated centers in Chile, Brazil, Paraguay, the Dominican Republic, Japan, China, and elsewhere. Partnering with and supporting existing UNESCO-IHP programs. ICIWaRM serves as the Global Technical Secretariat for IHP's Global Network on Water and Development Information in Arid Lands (G-WADI). In addition to directly supporting IHP, work through G-WADI helps the center to frame, prioritize and integrate its activities. With the recent release of the United Nation's 2030 Agenda for Sustainable Development, it is clear that

  8. Distribution of oxygen-18 and deuteriun in river waters across the United States

    Kendall, Carol; Coplen, Tyler B.

    2001-01-01

    Reconstruction of continental palaeoclimate and palaeohydrology is currently hampered by limited information about isotopic patterns in the modern hydrologic cycle. To remedy this situation and to provide baseline data for other isotope hydrology studies, more than 4800, depth- and width-integrated, stream samples from 391 selected sites within the USGS National Stream Quality Accounting Network (NASQAN) and Hydrologic Benchmark Network (HBN) were analysed for δ18O and δ2H (http://water.usgs.gov/pubs/ofr/ofr00-160/pdf/ofr00-160.pdf). Each site was sampled bimonthly or quarterly for 2·5 to 3 years between 1984 and 1987. The ability of this dataset to serve as a proxy for the isotopic composition of modern precipitation in the USA is supported by the excellent agreement between the river dataset and the isotopic compositions of adjacent precipitation monitoring sites, the strong spatial coherence of the distributions of δ18O and δ2H, the good correlations of the isotopic compositions with climatic parameters, and the good agreement between the ‘national’ meteoric water line (MWL) generated from unweighted analyses of samples from the 48 contiguous states of δ2H=8·11δ18O+8·99 (r2=0·98) and the unweighted global MWL of sites from the Global Network for Isotopes in Precipitation (GNIP) of the International Atomic Energy Agency and the World Meteorological Organization (WMO) of δ2H=8·17δ18O+10·35. The national MWL is composed of water samples that arise in diverse local conditions where the local meteoric water lines (LMWLs) usually have much lower slopes. Adjacent sites often have similar LMWLs, allowing the datasets to be combined into regional MWLs. The slopes of regional MWLs probably reflect the humidity of the local air mass, which imparts a distinctive evaporative isotopic signature to rainfall and hence to stream samples. Deuterium excess values range from 6 to 15‰ in the eastern half of the USA, along the northwest coast and on the Colorado

  9. Oxidation of eugenol by purified human term placental peroxidase.

    Zhang, R; Kulkarni, K A; Kulkarni, A P

    2000-01-01

    The oxidation of eugenol by purified human term placental peroxidase (HTPP) was examined. Spectral analyses indicated that, similar to horseradish peroxidase, HTPP is capable of catalyzing the oxidation of eugenol. The accumulated stable product in the reaction medium due to eugenol oxidation by HTPP was tentatively identified as quinone methide of eugenol (EQM). The EQM formation exhibited a pH optimum of 8.0 and was dependent on incubation time, amount of HTPP and the concentration of both eugenol and hydrogen peroxide. The specific activity of approx 2.8 micromoles of EQM/min/mg protein was observed with different preparations of HTPP. The EQM formation was significantly suppressed by glutathione and ascorbic acid. The classical peroxidase inhibitors viz. potassium cyanide and sodium azide blocked the reaction in a concentration manner. Collectively, the results suggest that eugenol may undergo peroxidative metabolism in human placenta. Copyright 2000 Harcourt Publishers Ltd.

  10. Gamma ray irradiation to semi-purified diet

    Takigawa, Akihiro; Danbara, Hiroshi; Ohyama, Yoshinobu

    1976-01-01

    Semi-purified diet containing 10% soybean oil was irradiated with gamma rays at levels of 0.6, 3 and 6 Mrad and was fed to chicks. Crude fat contents of the diets decreased and a considerable amount of peroxide was formed with high doses of irradiation. Feed consumption and feed efficiency of the highly irradiated diets were less than those of control. Metabolizable energy and digestibility of the diets, especially of fat, were decreased with the irradiation. The chicks fed with irradiated diets showed marked dilatation of the small intestine and the liver, and their erythrocytes were more fragile than those of control. The same phenomena were found with the chicks fed the diet containing the oil highly oxidized by autoxidation. Irradiation of the diet excluding oil showed little effect on the growth of chicks. It was considered that these phenomena were caused by the peroxide or other oxidation products of fat which were formed with gamma ray irradiation. (auth.)

  11. Regulated eukaryotic DNA replication origin firing with purified proteins.

    Yeeles, Joseph T P; Deegan, Tom D; Janska, Agnieszka; Early, Anne; Diffley, John F X

    2015-03-26

    Eukaryotic cells initiate DNA replication from multiple origins, which must be tightly regulated to promote precise genome duplication in every cell cycle. To accomplish this, initiation is partitioned into two temporally discrete steps: a double hexameric minichromosome maintenance (MCM) complex is first loaded at replication origins during G1 phase, and then converted to the active CMG (Cdc45-MCM-GINS) helicase during S phase. Here we describe the reconstitution of budding yeast DNA replication initiation with 16 purified replication factors, made from 42 polypeptides. Origin-dependent initiation recapitulates regulation seen in vivo. Cyclin-dependent kinase (CDK) inhibits MCM loading by phosphorylating the origin recognition complex (ORC) and promotes CMG formation by phosphorylating Sld2 and Sld3. Dbf4-dependent kinase (DDK) promotes replication by phosphorylating MCM, and can act either before or after CDK. These experiments define the minimum complement of proteins, protein kinase substrates and co-factors required for regulated eukaryotic DNA replication.

  12. Ground-water exploration in Al Marj area, Cyrenaica, United Kingdom of Libya

    Newport, T.G.; Haddor, Yousef

    1963-01-01

    The present report, based largely on fieldwork during 1959-61, describes the results of reconnaissance hydrogeologic studies and exploratory drilling to evaluate the general water-bearing properties of the rocks and the availability of groundwater supplies for irrigation, stock, and village uses in Al Marj area. These studies and the drilling were conducted under the auspices of the U.S. Operations Mission of the International Cooperation Administration. Al Marj area, located in the Province of Cyrenaica on the southern coast of the Mediterranean Sea, contains a land area of about 6,770 square kilometers. Along the Mediterranean shore is a narrow coastal plain that rises evenly to the base of an escarpment that forms the seaward front of an undulating plateau known as. Al Jabal al Akhgiar. The climate is semiarid; seasonal rainfall occurs during the winter months. Owing to orographic effects, the rainfall is somewhat higher in the Jabal than in the coastal plain. The average annual rainfall ranges from about 250 millimeters in the coastal plain to 450 millimeters on the Jabal. All the streams (wadis) of the area are ephemeral and flow only in response to heavy rains of the winter season. From a drainage divide on the Jabal some streams flow north and northwest toward the sea and the others, south and southeast to the interior desert. Solution features, such as limestone sink holes, are common in the coastal plain and a large solution depression occurs near Al Marj. The rocks of A1 Marj area consist predominantly of limestone and some sandstone and shale; they range from Cretaceous to Miocene age. On the coastal plain Miocene limestone is locally mantled by Quaternary alluvial, beach and lagoonal deposits. The Miocene and older beds have a regional southerly dip. These rocks are broken by northeast-trending normal faults in the coastal and inland escarpments. The ground-water reservoir is contained chiefly in fractures, bedding planes, and solution openings in the

  13. Thermal Analysis of a Thermal Energy Storage Unit to Enhance a Workshop Heating System Driven by Industrial Residual Water

    Wenqiang Sun

    2017-02-01

    Full Text Available Various energy sources can be used for room heating, among which waste heat utilization has significantly improved in recent years. However, the majority of applicable waste heat resources are high-grade or stable thermal energy, while the low-grade or unstable waste heat resources, especially low-temperature industrial residual water (IRW, are insufficiently used. A thermal energy storage (TES unit with paraffin wax as a phase change material (PCM is designed to solve this problem in a pharmaceutical plant. The mathematical models are developed to simulate the heat storage and release processes of the TES unit. The crucial parameters in the recurrence formulae are determined: the phase change temperature range of the paraffin wax used is 47 to 56 °C, and the latent heat is 171.4 kJ/kg. Several thermal behaviors, such as the changes of melting radius, solidification radius, and fluid temperature, are simulated. In addition, the amount of heat transferred, the heat transfer rate, and the heat storage efficiency are discussed. It is presented that the medicine production unit could save 10.25% of energy consumption in the investigated application.

  14. Magnetism for understanding catalyst analysis of purified carbon nanotubes

    Bellouard, Christine; Mercier, Guillaume; Cahen, Sébastien; Ghanbaja, Jaafar; Medjahdi, Ghouti [Institut Jean Lamour, CNRS-Université de Lorraine, BP 70239, 54506 Vandoeuvre-lès-Nancy (France); Gleize, Jérôme [Laboratoire de Chimie Physique-Approche Multi-échelle de Milieux Complexes-Université de Lorraine, 1 Bd Arago, 57078 Metz (France); Lamura, Gianrico [CNR-SPIN – Dipartimento di Fisica, via Dodecaneso 33, 16146 Genova (Italy); Hérold, Claire [Institut Jean Lamour, CNRS-Université de Lorraine, BP 70239, 54506 Vandoeuvre-lès-Nancy (France); Vigolo, Brigitte, E-mail: Brigitte.Vigolo@univ-lorraine.fr [Institut Jean Lamour, CNRS-Université de Lorraine, BP 70239, 54506 Vandoeuvre-lès-Nancy (France)

    2016-08-01

    The precise quantification of catalyst residues in purified carbon nanotubes is often a major issue in view of any fundamental and/or applicative studies. More importantly, since the best CNTs are successfully grown with magnetic catalysts, their quantification becomes strictly necessary to better understand intrinsic properties of CNT. For these reasons, we have deeply analyzed the catalyst content remained in nickel–yttrium arc-discharge single walled carbon nanotubes purified by both a chlorine-gas phase and a standard acid-based treatment. The study focuses on Ni analysis which has been investigated by transmission electron microscopy, X-ray diffraction, thermogravimetry analysis, and magnetic measurements. In the case of the acid-based treatment, all quantifications result in a decrease of the nanocrystallized Ni by a factor of two. In the case of the halogen gas treatment, analysis and quantification of Ni content is less straightforward: a huge difference appears between X-ray diffraction and thermogravimetry results. Thanks to magnetic measurements, this disagreement is explained by the presence of Ni{sup 2+} ions, belonging to NiCl{sub 2} formed during the Cl-based purification process. In particular, NiCl{sub 2} compound appears under different magnetic/crystalline phases: paramagnetic or diamagnetic, or well intercalated in between carbon sheets with an ordered magnetic phase at low temperature. - Highlights: • Cl-gas treatment of Ni catalyst of carbon nanotubes leads to NiCl{sub 2} residue. • Magnetic measurements show the transformation of Ni{sup 0} in Ni{sup 2+}through a purification process. • High temperature Cl treatment removes 75% of metallic impurities. • Cl-purification yields to an amount of metal of 1.5% in arc-discharge CNT samples.

  15. Spacesuit Water Membrane Evaporator; An Enhanced Evaporative Cooling System for the Advanced Extravehicular Mobility Unit Portable Life Support System

    Bue, Grant C.; Makinen, Janice V.; Miller, Sean; Campbell, Colin; Lynch, Bill; Vogel, Matt; Craft, Jesse; Wilkes, Robert; Kuehnel, Eric

    2014-01-01

    Development of the Advanced Extravehicular Mobility Unit (AEMU) portable life support subsystem (PLSS) is currently under way at NASA Johnson Space Center. The AEMU PLSS features a new evaporative cooling system, the Generation 4 Spacesuit Water Membrane Evaporator (Gen4 SWME). The SWME offers several advantages when compared with prior crewmember cooling technologies, including the ability to reject heat at increased atmospheric pressures, reduced loop infrastructure, and higher tolerance to fouling. Like its predecessors, Gen4 SWME provides nominal crew member and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crew member and PLSS electronics. Test results from the backup cooling system which is based on a similar design and the subject of a companion paper, suggested that further volume reductions could be achieved through fiber density optimization. Testing was performed with four fiber bundle configurations ranging from 35,850 fibers to 41,180 fibers. The optimal configuration reduced the Gen4 SWME envelope volume by 15% from that of Gen3 while dramatically increasing the performance margin of the system. A rectangular block design was chosen over the Gen3 cylindrical design, for packaging configurations within the AEMU PLSS envelope. Several important innovations were made in the redesign of the backpressure valve which is used to control evaporation. A twin-port pivot concept was selected from among three low profile valve designs for superior robustness, control and packaging. The backpressure valve motor, the thermal control valve, delta pressure sensors and temperature sensors were incorporated into the manifold endcaps, also for packaging considerations. Flight-like materials including a titanium housing were used for all components. Performance testing

  16. Climate change and the water cycle: A new southwest regional climate hub curriculum unit for 6th-12th grade students

    As climate change intensifies, increased temperatures and altered precipitation will make water, a limited resource in the arid southwestern United States, even scarcer in many locations. The USDA Southwest Regional Climate Hub (SWRCH) developed Climate Change and the Water Cycle, an engaging and sc...

  17. Combining remote sensing and water-balance evapotranspiration estimates for the conterminous United States

    Reitz, Meredith; Senay, Gabriel; Sanford, Ward E.

    2017-01-01

    Evapotranspiration (ET) is a key component of the hydrologic cycle, accounting for ~70% of precipitation in the conterminous U.S. (CONUS), but it has been a challenge to predict accurately across different spatio-temporal scales. The increasing availability of remotely sensed data has led to significant advances in the frequency and spatial resolution of ET estimates, derived from energy balance principles with variables such as temperature used to estimate surface latent heat flux. Although remote sensing methods excel at depicting spatial and temporal variability, estimation of ET independently of other water budget components can lead to inconsistency with other budget terms. Methods that rely on ground-based data better constrain long-term ET, but are unable to provide the same temporal resolution. Here we combine long-term ET estimates from a water-balance approach with the SSEBop (operational Simplified Surface Energy Balance) remote sensing-based ET product for 2000–2015. We test the new combined method, the original SSEBop product, and another remote sensing ET product (MOD16) against monthly measurements from 119 flux towers. The new product showed advantages especially in non-irrigated areas where the new method showed a coefficient of determination R2 of 0.44, compared to 0.41 for SSEBop or 0.35 for MOD16. The resulting monthly data set will be a useful, unique contribution to ET estimation, due to its combination of remote sensing-based variability and ground-based long-term water balance constraints.

  18. Simulation model of a single-stage lithium bromide-water absorption cooling unit

    Miao, D.

    1978-01-01

    A computer model of a LiBr-H2O single-stage absorption machine was developed. The model, utilizing a given set of design data such as water-flow rates and inlet or outlet temperatures of these flow rates but without knowing the interior characteristics of the machine (heat transfer rates and surface areas), can be used to predict or simulate off-design performance. Results from 130 off-design cases for a given commercial machine agree with the published data within 2 percent.

  19. Studying the dynamical characteristics of pumps in NPP unit auxiliary water system under operational conditions

    Belyaev, S.G.; Puzanov, A.I.; Belikov, V.P.; Dizik, B.S.

    1990-01-01

    Hydrodynamic loads appearing in the flow-through part of pump aggregates of the system of auxiliary water supply in NPP with variations in the operation modes are investigated. It is shown that during operation of centrifugal pumps the position of the mode on the pump characteristic plot must be controlled. When the mode point exceeds the limits of the working zone it results in a considerable increase of dynamic loads: pressure pulsation and vibration. As the flow rate increase the decrease in dynamic loads is recorded at low frequencies of about 2-4 Hz

  20. Theoretical-empirical model of the steam-water cycle of the power unit

    Grzegorz Szapajko

    2010-06-01

    Full Text Available The diagnostics of the energy conversion systems’ operation is realised as a result of collecting, processing, evaluatingand analysing the measurement signals. The result of the analysis is the determination of the process state. It requires a usageof the thermal processes models. Construction of the analytical model with the auxiliary empirical functions built-in brings satisfyingresults. The paper presents theoretical-empirical model of the steam-water cycle. Worked out mathematical simulation model containspartial models of the turbine, the regenerative heat exchangers and the condenser. Statistical verification of the model is presented.

  1. Tamarisk control, water salvage, and wildlife habitat restoration along rivers in the western United States

    Shafroth, Patrick B.

    2006-01-01

    In the latter part of the 19th century, species of the nonnative shrub tamarisk (also called saltcedar; for example, Tamarix ramosissima, T. chinensis) were introduced to the United States for use as ornamental plants for erosion control. By 1877, some naturalized populations had become established, and by the 1960s, tamarisk was present along most rivers in the semi-arid and arid parts of the West and was quite abundant along downstream ranches of the major southwest rivers such as the Colorado, Rio Grande, Gila, and Pecos. The principal period of tamarisk invasion coincided with changing physical conditions along western rivers associated with the construction and operation of dams. In many cases, these altered physical conditions appear to have been more favorable for tamarisk than native riparian competitors like cottonwoods and willows (Populus and Salix; Glenn and Nagler, 2005).

  2. Investigation of Ground-Water Contamination at Solid Waste Management Unit 12, Naval Weapons Station Charleston, North Charleston, South Carolina

    Vroblesky, Don A.; Casey, Clifton C.; Petkewich, Matthew D.; Lowery, Mark A.; Conlon, Kevin J.; Harrelson, Larry G.

    2007-01-01

    The U.S. Geological Survey and the Naval Facilities Engineering Command Southeast investigated natural and engineered remediation of chlorinated volatile organic compound ground-water contamination at Solid Waste Management Unit 12 at the Naval Weapons Station Charleston, North Charleston, South Carolina. The primary contaminants of interest are tetrachloroethene, 1,1,1-trichloroethane, trichloroethene, cis-1,2-dichloroethene, vinyl chloride, 1,1-dichloroethane, and 1,1-dichloroethene. In general, the hydrogeology of Solid Waste Management Unit 12 consists of a surficial aquifer, composed of sand to clayey sand, overlain by dense clay that extends from about land surface to a depth of about 8 to 10 feet and substantially limits local recharge. During some months in the summer, evapotranspiration and limited local recharge result in ground-water level depressions in the forested area near wells 12MW-12S and 12MW-17S, seasonally reflecting the effects of evapotranspiration. Changes in surface-water levels following Hurricane Gaston in 2004 resulted in a substantial change in the ground-water levels at the site that, in turn, may have caused lateral shifting of the contaminant plume. Hydraulic conductivity, determined by slug tests, is higher along the axis of the plume in the downgradient part of the forests than adjacent to the plume, implying that there is some degree of lithologic control on the plume location. Hydraulic conductivity, hydraulic gradient, sulfur-hexafluoride measurements, and historical data indicate that ground-water flow rates are substantially slower in the forested area relative to upgradient areas. The ground-water contamination, consisting of chlorinated volatile organic compounds, extends eastward in the surficial aquifer from the probable source area near a former underground storage tank. Engineered remediation approaches include a permeable reactive barrier and phytoremediation. The central part of the permeable reactive barrier along the

  3. Environmentally relevant chemical mixtures of concern in waters of United States tributaries to the Great Lakes

    Elliott, Sarah M.; Brigham, Mark E.; Kiesling, Richard L.; Schoenfuss, Heiko L.; Jorgenson, Zachary G.

    2018-01-01

    The North American Great Lakes are a vital natural resource that provide fish and wildlife habitat, as well as drinking water and waste assimilation services for millions of people. Tributaries to the Great Lakes receive chemical inputs from various point and nonpoint sources, and thus are expected to have complex mixtures of chemicals. However, our understanding of the co‐occurrence of specific chemicals in complex mixtures is limited. To better understand the occurrence of specific chemical mixtures in the US Great Lakes Basin, surface water from 24 US tributaries to the Laurentian Great Lakes was collected and analyzed for diverse suites of organic chemicals, primarily focused on chemicals of concern (e.g., pharmaceuticals, personal care products, fragrances). A total of 181 samples and 21 chemical classes were assessed for mixture compositions. Basin wide, 1664 mixtures occurred in at least 25% of sites. The most complex mixtures identified comprised 9 chemical classes and occurred in 58% of sampled tributaries. Pharmaceuticals typically occurred in complex mixtures, reflecting pharmaceutical‐use patterns and wastewater facility outfall influences. Fewer mixtures were identified at lake or lake‐influenced sites than at riverine sites. As mixture complexity increased, the probability of a specific mixture occurring more often than by chance greatly increased, highlighting the importance of understanding source contributions to the environment. This empirically based analysis of mixture composition and occurrence may be used to focus future sampling efforts or mixture toxicity assessments. 

  4. Antioxidant and antibacterial activities of polysaccharides isolated and purified from Diaphragma juglandis fructus.

    Meng, Qingran; Li, Yinghao; Xiao, Tiancun; Zhang, Lianfu; Xu, Dan

    2017-12-01

    A water-soluble polysaccharide fraction (DJP-2) isolated from Diaphragma juglandis was successfully purified by ion-exchange chromatography (DEAE-cellulose) and gel-permeation chromatography (Sephadex G-100). The weight-average molecular weight (Mw) and number-average molecular weight (Mn) of DJP-2 were 4.95 and 3.99kDa, respectively. Monosaccharide component analysis indicated that DJP-2 comprised arabinose, galactose, glucose, xylose, and mannose in a molar ratio of 0.27:0.55:1:0.14:0.08. The evaluation of the antioxidant and antibacterial activities of polysaccharides from Diaphragma juglandis fructus indicated that they could be explored as promising natural antioxidant and bacteriostatic agents in the food and pharmaceutical industries. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Enriched surface acidity for surfactant-free suspensions of carboxylated carbon nanotubes purified by centrifugation

    Elizabeth I. Braun

    2016-06-01

    Full Text Available It is well known that surfactant-suspended carbon nanotube (CNT samples can be purified by centrifugation to decrease agglomerates and increase individually-dispersed CNTs. However, centrifugation is not always part of protocols to prepare CNT samples used in biomedical applications. Herein, using carboxylated multi-walled CNTs (cMWCNTs suspended in water without a surfactant, we developed a Boehm titrimetric method for the analysis of centrifuged cMWCNT suspensions and used it to show that the surface acidity of oxidized carbon materials in aqueous cMWCNT suspensions was enriched by ∼40% by a single low-speed centrifugation step. This significant difference in surface acidity between un-centrifuged and centrifuged cMWCNT suspensions has not been previously appreciated and is important because the degree of surface acidity is known to affect the interactions of cMWCNTs with biological systems.

  6. A study of the process of two staged anaerobic fermentation as a possible method for purifying sewage

    Inoue, Y; Kouama, K; Matsuo, T

    1983-01-01

    Great attention has recently been given to the study of the processes of anaerobic fermentation, which may become alternatives to the existing methods for purifying waste waters which use aerobic microorganisms. A series of experimentswere conducted with the use of an artificially prepared liquid (fermented milk and starch) which imitates the waste to be purified, in order to explain the capabilities of the process of two staged anaerobic fermentation (DAS) as a method for purifying waste waters. The industrial system of the process includes: a fermentation vat for acetic fermentation with recirculation of the sediment, a primary settler, a fermentation tank for methane fermentation and a secondary settler. The process was conducted at a loading speed (based on Carbon) from 0.15 to 0.4 kilograms per cubic meter per day at a temperature of 38C. The degree of conversion of the fermented organic substances into volatile organic acids was not a function of the loading speed and was 54 to 57 percent in the acetic fermentation tank, where 95 to 97 percent of the organic material was broken down with the production of methane and carbon dioxide.

  7. A Methylmercury Prediction Too For Surface Waters Across The Contiguous United States (Invited)

    Krabbenhoft, D. P.; Booth, N.; Lutz, M.; Fienen, M. N.; Saltman, T.

    2009-12-01

    About 20 years ago, researchers at a few locations across the globe discovered high levels of mercury in fish from remote settings lacking any obvious mercury source. We now know that for most locations atmospheric deposition is the dominant mercury source, and that mercury methylation is the key process that translates low mercury loading rates into relatively high levels in top predators of aquatic food webs. Presently, almost all US states have advisories for elevated levels of mercury in sport fish, and as a result there is considerable public awareness and concern for this nearly ubiquitous contaminant issue. In some states, “statewide” advisories have been issued because elevated fish mercury levels are so common, or the state has no effective way to monitor thousands of lakes, reservoirs, wetlands, and streams. As such, resource managers and public health officials have limited options for informing the public on of where elevated mercury concentrations in sport fish are more likely to occur than others. This project provides, for the first time, a national map of predicted (modeled) methylmercury concentrations in surface waters, which is the most toxic and bioaccumulative form of mercury in the environment. The map is the result of over two decades of research that resulted in the formulation of conceptual models of the mercury methylation process, which is strongly governed by environmental conditions - specifically hydrologic landscapes and water quality. The resulting predictive map shows clear regional trends in the distribution of methylmercury concentrations in surface waters. East of the Mississippi, the Gulf and southeastern Atlantic coast, the northeast, the lower Mississippi valley, and Great Lakes area are predicted to have generally higher environmental methylmercury levels. Higher-elevation, well-drained areas of Appalachia are predicted to have relatively lower methylmercury abundance. Other than the prairie pothole region, in the western

  8. Fuel performance in the Barsebeck boiling water reactors (Unit 1 and 2)

    Norman, B.

    1979-01-01

    Sydkraft is the largest privately owned utility in Sweden. It serves about 20% of the Swedish population with about 12 TWh of electric power per year, of which 64% is nuclear (1978 figures). The two identical 590 MWE ASEA-ATOM boiling water reactors in Barsebeck have been in operation since 1975 and 1977 respectively. Fission product activity in the primary circuits and in the off-gas systems is extremely low and indicate a near perfect fuel condition. Operating restrictions limiting the effect of pellet cladding interaction have been in use since initial start-up and testing. A few events involving rapid power increases above the preconditioned power level have occurred without causing fuel failures. It is believed that an analysis of power reactor operational transients, which did not cause fuel failures, can be useful to design more adequate and less conservative rules for the operation of nuclear reactor cores

  9. Ground-water quality in three urban areas in the Coastal Plain of the southeastern United States, 1995

    Berndt, M.P.; Galeone, D.R.; Spruill, T.B.; Crandall, C.A.

    1998-01-01

    Ground-water quality is generally good in three urban areas studied in the Coastal Plain of the southeastern United States?Ocala and Tampa, Florida, and Virginia Beach, Virginia. The hydrology of these areas differs in that Ocala has many karst depressions but virtually no surface-water features, and Tampa and Virginia Beach have numerous surface-water features, including small lakes, streams, and swamps. Samples were collected in early 1995 from 15 wells in Ocala (8 in the surficial aquifer and 7 in the Upper Floridan aquifer), 17 wells in Tamps (8 in the surficial aquifer and 9 in the Upper Floridan aquifer), and in the summer of 1995 from 15 wells in Virginia Beach (all in the surficial aquifer). In the surficial aquifer in Ocala, the major ion water type was calcium bicarbonate in five samples and mixed (no dominant ions) in three samples, with dissolved-solids concentrations ranging from 78 to 463 milligrams per liter. In Tampa, the water type was calcium bicarbonate in one sample and mixed in seven samples, with dissolved-solids concentrations ranging from 38 to 397 milligrams per liter. In Virginia Beach, water types were primarily calcium and sodium bicarbonate water, with dissolved-solids concentrations ranging from 89 to 740 milligrams per liter. The water types and dissolved-solids concentrations reflect the presence of carbonates in the surficial aquifer materials in the Ocala and Virginia Beach areas. The major ion water type was calcium bicarbonate for all 16 samples from the upper Floridan aquifer in both Florida cities. Dissolved-solids concentrations ranged from 210 to 551 milligrams per liter in Ocala, with a median of 287 milligrams per liter, and from 187 to 362 milligrams per liter in Tampa, with a median of 244 milligrams per liter. Concentrations of nitrate nitrogen were highest in the surficial aquifer in Ocala, and one sample exceeded 10 milligrams per liter, the U.S. Environmental Protection Agency maximum contaminant level for drinking

  10. [Digestive utilization of purified cellulose in the rainbow trout (Salmo gairdneri) and the common carp (Cyprinus carpio)].

    Bergot, F

    1981-01-01

    A semi-purified diet containing 22 p. 100 of a wood cellulose extract without lignin but still containing 22 p. 100 of hemicelluloses was distributed for one month to rainbow trout and common carp reared at 17 and 20 degrees C, respectively. The digestibility of the main dietary constituents was determined by an indirect method using chrome oxide as an inert tracer. The feces were recovered by a continuous automatic collector which rapidly removed them from the water, minimizing alteration by leaching. The cellulose content was estimated by the Weende (crude fiber) and the Van Soest (neutral detergent fiber and acid detergent fiber) methods. The digestibility coefficients obtained for trout as well as for carp indicate that cellulose and hemicelluloses were not digested. In both species, volatile fatty acid concentration in the different segments of the digestive tract was low (less than 10 mM/l). These results lead us to suggest that trout and carp cannot degrade purified cellulose.

  11. A Novel Nanosecond Pulsed Power Unit for the Formation of ·OH in Water

    Li, Shengli; Hu, Sheng; Zhang, Han

    2012-04-01

    A novel nanosecond pulsed power unit was developed for plasma treatment of wastewater, based on the theory of magnetic pulse compression and semiconductor opening switch (SOS). The peak value, rise time and pulse duration of the output voltage were observed to be -51 kV, 60 ns and 120 ns, respectively. The concentrations of ·OH generated by the novel nanosecond pulsed plasma power were determined using the method of high-performance liquid chromatography (HPLC). The results showed that the concentrations of ·OH increased with the increase in peak voltage, and the generation rates of ·OH were 4.1 × 10-10 mol/s, 5.7 × 10-10 mol/s, and 7.7 × 10-10 mol/s at 30 kV, 35 kV, and 40 kV, respectively. The efficiency of OH generation was found to be independent of the input parameters for applied power, with an average value of 3.23×10-12 mol/J obtained.

  12. Lifetime Neutron Fluence Analysis of the Ringhals Unit 1 Boiling Water Reactor

    Kulesza Joel A.

    2016-01-01

    Full Text Available This paper describes a neutron fluence assessment considering the entire commercial operating history (35 cycles or ∼ 25 effective full power years of the Ringhals Unit 1 reactor pressure vessel beltline region. In this assessment, neutron (E >1.0 MeV fluence and iron atom displacement distributions were calculated on the moderator tank and reactor pressure vessel structures. To validate those calculations, five in-vessel surveillance chain dosimetry sets were evaluated as well as material samples taken from the upper core grid and wide range neutron monitor tubes to act as a form of retrospective dosimetry. During the analysis, it was recognized that delays in characterizing the retrospective dosimetry samples reduced the amount of reactions available to be counted and complicated the material composition determination. However, the comparisons between the surveillance chain dosimetry measurements (M and calculated (C results show similar and consistent results with the linear average M/C ratio of 1.13 which is in good agreement with the resultant least squares best estimate (BE/C ratios of 1.10 for both neutron (E >1.0 MeV flux and iron atom displacement rate.

  13. A Novel Nanosecond Pulsed Power Unit for the Formation of ·OH in Water

    Li Shengli; Hu Sheng; Zhang Han

    2012-01-01

    A novel nanosecond pulsed power unit was developed for plasma treatment of wastewater, based on the theory of magnetic pulse compression and semiconductor opening switch (SOS). The peak value, rise time and pulse duration of the output voltage were observed to be -51 kV, 60 ns and 120 ns, respectively. The concentrations of ·OH generated by the novel nanosecond pulsed plasma power were determined using the method of high-performance liquid chromatography (HPLC). The results showed that the concentrations of ·OH increased with the increase in peak voltage, and the generation rates of ·OH were 4.1 × 10 -10 mol/s, 5.7 × 10 -10 mol/s, and 7.7 × 10 -10 mol/s at 30 kV, 35 kV, and 40 kV, respectively. The efficiency of OH generation was found to be independent of the input parameters for applied power, with an average value of 3.23×10 -12 mol/J obtained. (plasma technology)

  14. A two-step crushed lava rock filter unit for grey water treatment at household level in an urban slum.

    Katukiza, A Y; Ronteltap, M; Niwagaba, C B; Kansiime, F; Lens, P N L

    2014-01-15

    Decentralised grey water treatment in urban slums using low-cost and robust technologies offers opportunities to minimise public health risks and to reduce environmental pollution caused by the highly polluted grey water i.e. with a COD and N concentration of 3000-6000 mg L(-1) and 30-40 mg L(-1), respectively. However, there has been very limited action research to reduce the pollution load from uncontrolled grey water discharge by households in urban slums. This study was therefore carried out to investigate the potential of a two-step filtration process to reduce the grey water pollution load in an urban slum using a crushed lava rock filter, to determine the main filter design and operation parameters and the effect of intermittent flow on the grey water effluent quality. A two-step crushed lava rock filter unit was designed and implemented for use by a household in the Bwaise III slum in Kampala city (Uganda). It was monitored at a varying hydraulic loading rate (HLR) of 0.5-1.1 m d(-1) as well as at a constant HLR of 0.39 m d(-1). The removal efficiencies of COD, TP and TKN were, respectively, 85.9%, 58% and 65.5% under a varying HLR and 90.5%, 59.5% and 69%, when operating at a constant HLR regime. In addition, the log removal of Escherichia coli, Salmonella spp. and total coliforms was, respectively, 3.8, 3.2 and 3.9 under the varying HLR and 3.9, 3.5 and 3.9 at a constant HLR. The results show that the use of a two-step filtration process as well as a lower constant HLR increased the pollutant removal efficiencies. Further research is needed to investigate the feasibility of adding a tertiary treatment step to increase the nutrients and microorganisms removal from grey water. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Light water reactor (LWR) innovation needs in the United States: The Massachusetts Institute of Technology LWR innovation project

    Golay, M.W.

    1988-01-01

    A major effort under way within the Massachusetts Institute of Technology (MIT) Engineering School is focused on the contributions that technology innovation can make in revitalizing nuclear power in the United States. A principal component of this effort is a project to improve the designs of the next generation of light water reactors (LWRs) with emphasis on achieving improved capacity factors and safety, and reducing the construction duration. The motivation for this overall effort is to prevent the nuclear option from being unnecessarily lost by being available only in uneconomic configurations. In considering how to advance this effort, the authors focused on refining the designs of new reactors because this is the area where the greatest opportunities for improvements exist

  16. A feasibility study on active ultrasonic techniques for water into sodium leak detection on FBR steam generator units

    Girard, J.P.; Garnaud, P.; Journeau, C.; Demarais, R.

    1990-01-01

    In the framework of the European Fast Breeder Project one of the aims is to provide the ferritic straight tube steam generator with a fast and reliable leak detection system. The first studies of water sodium leaks, based on the passive listening of noise source, are described. Considerable experience has been acquired of this technique and one of the conclusions is that a high level of reliability may require a sophisticated surveillance algorithm. Further works on the subject should lead to demonstration phase in 1993-1995 on a real and representative steam generator unit in order to have the benefit of a long term run of the surveillance method prior to industrial use in a compulsory safety system. 1 ref., 10 figs

  17. Methods used to characterize the chemical composition and biological activity of environmental waters throughout the United States, 2012-14

    Romanok, Kristin M.; Reilly, Timothy J.; Barber, Larry B.; Boone, J. Scott; Buxton, Herbert T.; Foreman, William T.; Furlong, Edward T.; Hladik, Michelle; Iwanowicz, Luke R.; Journey, Celeste A.; Kolpin, Dana W.; Kuivila, Kathryn; Loftin, Keith A.; Mills, Marc A.; Meyer, Michael T.; Orlando, James L.; Smalling, Kelly L.; Villeneuve, Daniel L.; Bradley, Paul M.

    2017-03-22

    A vast array of chemical compounds are in wide commercial use in the United States, and the potential ecological and human-health effect of exposure to chemical mixtures has been identified as a high priority in environment health science. Awareness of the potential effects of low-level chemical exposures is rising. The U.S. Geological Survey, in cooperation with the U.S. Environmental Protection Agency, conducted a study in which samples were collected from 38 streams in 25 States to provide an overview of contaminants found in stream water across the Nation. Additionally, biological screening assays were used to help determine any potential ecological and human-health effects of these chemical mixtures and to prioritize target chemicals for future toxicological studies. This report describes the site locations and the sampling and analytical methods and quality-assurance procedures used in the study.

  18. Estimates of water use and trends in the Colorado River Basin, Southwestern United States, 1985–2010

    Maupin, Molly A.; Ivahnenko, Tamara I.; Bruce, Breton

    2018-06-26

    The Colorado River Basin (CRB) drains 246,000 square miles and includes parts of California, Colorado, Nevada, New Mexico, Utah, and Wyoming, and all of Arizona (Basin States). This report contains water-use estimates by category of use for drainage basins (Hydrologic Unit Code 8; HUC‑8) within the CRB from 1985 to 2010, at 5-year intervals. Estimates for public supply, domestic, commercial, industrial, irrigation, livestock, mining, aquaculture, hydroelectric and thermoelectric power, and wastewater returns are tabulated as (1) water withdrawals from groundwater or surface‑water sources of fresh or saline quality, (2) water delivered for domestic use, (3) wastewater returns and instream use (hydroelectric), and (4) consumptive use, or water that is consumed (USGS definition) and not available for immediate reuse. Water transported outside of the CRB (interbasin transfers) is not included as part of withdrawals and are not accounted for in any category of use within the CRB.Total withdrawals in the CRB (excluding interbasin transfers) averaged about 17 million acre-feet (maf) from 1985 to 2010, peaked at about 17.76 maf in 2000, and reached their lowest levels of 16.43 maf in 1990. Interbasin transfers to serve mostly public-supply and irrigation needs outside of the CRB are reported for 2000, 2005, and 2010 only, and averaged 5.40 maf. More surface water was used in the CRB than groundwater, averaging about 78 percent of total withdrawals, and its use increased less than 2 percent from 1985 to 2010, while groundwater withdrawals decreased about 12 percent. From 1985 to 2010, surface water averaged 98 percent of withdrawals in the upper CRB, and about 59 percent in the lower CRB. Nearly all withdrawals were freshwater, but some saline groundwater was used for mining and self-supplied industrial.Interbasin transfers have a large effect on flows in the Colorado River and are listed in this report separately with no explanation of how the water is used outside of

  19. High efficiency-large capacity circulating water pump for Hamaoka Nuclear Power Station unit No.3

    Ito, Akihiko; Sasamuro, Takemi; Takeda, Hirohisa.

    1988-01-01

    No.3 plant in the Hamaoka Nuclear Power Station, Chube Electric Power Co., Inc. is the latest plant of 1100 MW class BWR type, which began the commercial operation in August, 1987. The seawater intake and discharge system of this plant is composed of the channel exceeding 2 km in the total length from the intake tower to the discharge port. The circulating water pump installed in this system has the capacity of 1620 m 3 /min and the total head of 16.5 m, which are the largest in the world. It attained the efficiency as high as more than 90%. Three pumps supply seawater to three-body condensers. The design of the impeller and the casing for obtaining high efficiency, the structural design for facilitating maintenance, the manufacture of a model pump and the performance test using it and so on are reported. The most important item in the manufacture was the form of the onebody impeller weighing 4.5t. The confirmation of the performance of the actual machines was carried out as a part of the synthetic function confirmation test at the power station, and the flow rate was measured with Pitot tubes and ultrasonic flowmeters. (Kako, I.)

  20. Long-term water chemistry database, Little River Experimental Watershed, southeast Coastal Plain, United States

    Feyereisen, G. W.; Lowrance, R.; Strickland, T. C.; Sheridan, J. M.; Hubbard, R. K.; Bosch, D. D.

    2007-09-01

    A water quality sampling program was initiated in 1974 by the U.S. Department of Agriculture Agricultural Research Service on the 334 km2 Little River Experimental Watershed (LREW) near Tifton in south Georgia to monitor the effects of changing land use and agricultural practices over time and to support development of simulation models capable of predicting future impacts of agricultural land use and management changes. Stream samples were taken on a weekly or more frequent basis and were analyzed for chloride, ammonium nitrogen, nitrate plus nitrite nitrogen, total kjeldahl nitrogen, total phosphorus, and dissolved molybdate reactive phosphorus. Monitoring began in 1974 on the entire watershed and four nested subwatersheds, ranging in size from 16.7 to 114.9 km2, and continues until present. Partial records of 7, 10, and 19 years exist for three additional subwatersheds. Suspended solids data are available for all eight subwatersheds for 1974-1978 and 1979-1981, three subwatersheds for 1982-1986, and all eight subwatersheds again beginning in the year 2000. The concentration and associated load data are being published on the LREW database anonymous ftp site (ftp://www.tiftonars.org/).

  1. Spacesuit Water Membrane Evaporator Integration with the ISS Extravehicular Mobility Unit

    Margiott, Victoria; Boyle, Robert

    2014-01-01

    NASA has developed a Solid Water Membrane Evaporation (SWME) to provide cooling for the next generation spacesuit. The current spacesuit team has looked at this technology from the standpoint of using the ISS EMU to demonstrate the SWME technology while EVA, and from the standpoint of augmenting EMU cooling in the case of a fouled EMU cooling system. One approach to increasing the TRL of the system is to incorporate this hardware with the existing EMU. Several integration issues were addressed to support a potential demonstration of the SWME with the existing EMU. Systems analysis was performed to assess the capability of the SWME to maintain crewmember cooling and comfort as a replacement for sublimation. The materials of the SWME were reviewed to address compatibility with the EMU. Conceptual system placement and integration with the EMU via an EVA umbilical system to ensure crew mobility and Airlock egress were performed. A concept of operation for EVA use was identified that is compatible with the existing system. This concept is extensible as a means to provide cooling for the existing EMU. The cooling system of one of the EMUs on orbit has degraded, with the root cause undetermined. Should there be a common cause resident on ISS, this integration could provide a means to recover cooling capability for EMUs on orbit.

  2. The interaction with suspended and settled sedimentary materials of long-lived radionuclides discharged into United Kingdom coastal waters

    Pentreath, R. J.

    1987-11-01

    Low-level liquid radioactive wastes are routinely discharged under authorization into United Kingdom coastal waters from nuclear reactor sites, from nuclear fuel reprocessing and fabrication plants, and from other facilities connected with the nuclear industries. The effluents contain a wide range of radionuclides, with greatly varying half-lives and in different chemical forms. The receiving environments are also markedly different. All of these factors need to be taken into account in order that the authorizations for discharge are based on a sound knowledge of the underlying environmental science as well as meeting the objectives of radiological protection. The largest research effort has been expended on the longer-lived nuclides discharged from the BNFL plant at Sellafield into the Irish Sea. These studies have focused on such aspects as the nature of the effluent, the dispersion of the soluble nuclides out of the Irish Sea, the retention of other nuclides within it, and the incorporation of radionuclides into settled sediments. Some comparisons have also been made between other sites by observing the concentrations of radionuclides in similar materials, at similar distances, per unit rate of discharge. Although these studies are useful in developing an understanding of the dynamics of radionuclides in coastal environments, it is essential to have a wider and more general knowledge if the long-term consequences of discharging radionuclides—or any other chemical waste—into coastal waters are to be fully evaluated. These consequences are assessed by the use of models which have, necessarily, to simplify many of the processes involved. It is therefore all the more important that the underlying science relating to the nature and behaviour of the wastes, and of the receiving environment, is fully explored, and that the assumptions used in the models can be satisfactorily validated.

  3. Challenge theme 2: assuring water availability and quality in the 21st century: Chapter 4 in United States-Mexican Borderlands: Facing tomorrow's challenges through USGS science

    Callegary, James; Langeman, Jeff; Leenhouts, Jim; Martin, Peter

    2013-01-01

    Along the United States–Mexican border, the health of communities, economies, and ecosystems is inextricably intertwined with the availability and quality of water, but effective water management in the Borderlands is complicated. Water users compete for resources, and their needs are increasing. Managers are faced with issues such as finding a balance between agriculture and rapidly growing cities or maintaining public supplies while ensuring sufficient resources for aquatic ecosystems. In addition to human factors, the dry climate of the Borderlands, as compared to more temperate regions, also increases the challenge of balancing water supplies between humans and ecosystems. Warmer, drier, and more variable conditions across the southwestern United States—the projected results of climate change (Seager and others, 2007)—would further stress water supplies.

  4. Full scale demonstration of air-purifying pavement

    Ballari, M.M.; Brouwers, H.J.H.

    2013-01-01

    Highlights: ► The results of a demonstration project for photocatalytic pavement are shown. ► The photocatalytic performance was studied in a street as well as on lab scale. ► The outdoor monitoring was performed in different seasons and weather conditions. ► The NO x concentration was in average 19% lowered by the photocatalytic street. ► Under ideal weather conditions the NO x reduction reached up to 45%. -- Abstract: Experiments concerning a full-scale demonstration of air purifying pavement in Hengelo, The Netherlands, are reported. The full width of the street was provided with concrete pavement containing TiO 2 over a length of 150 m (“DeNO x street”). Another part of the street, about 100 m, was paved with normal paving blocks (“Control street”). The outdoor monitoring was done during 26 days for a period exceeding one year, and measured parameters included traffic intensity, NO, NO 2 and ozone concentrations, temperature, relative humidity, wind speed and direction, and the visible and UV light irradiance. Prior and parallel to these field measurements, the used blocks were also measured in the lab to assess their performance. The NO x concentration was, on average, 19% (considering the whole day) and 28% (considering only afternoons) lower than the obtained values in the Control street. Under ideal weather conditions (high radiation and low relative humidity) a NO x concentration decrease of 45% could be observed

  5. Production of Purified CasRNPs for Efficacious Genome Editing.

    Lingeman, Emily; Jeans, Chris; Corn, Jacob E

    2017-10-02

    CRISPR-Cas systems have been harnessed as modular genome editing reagents for functional genomics and show promise to cure genetic diseases. Directed by a guide RNA, a Cas effector introduces a double stranded break in DNA and host cell DNA repair leads to the introduction of errors (e.g., to knockout a gene) or a programmed change. Introduction of a Cas effector and guide RNA as a purified Cas ribonucleoprotein complex (CasRNP) has recently emerged as a powerful approach to alter cell types and organisms. Not only does CasRNP editing exhibit increased efficacy and specificity, it avoids optimization and iteration of species-specific factors such as codon usage, promoters, and terminators. CasRNP editing has been rapidly adopted for research use in many contexts and is quickly becoming a popular method to edit primary cells for therapeutic application. This article describes how to make a Cas9 RNP and outlines its use for gene editing in human cells. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  6. Production of rabbit antibodies against purified Glucose oxidase

    Muhammad Anjum Zia

    2012-02-01

    Full Text Available Glucose oxidase is an active oxygen species generating enzyme produced from Aspergillus niger grown in submerged fermentation. Disintegration of the mycelium resulted in high glucose oxidase activity that was subjected to ammonium sulfate precipitation at 60-85% saturation rates that resulted to 6.14 U mg -1 specific activity. Purification of enzyme by anion exchange column (DEAE-Cellulose resulted into 22.53 U mg-1 specific activity and 10.27 fold purification. This was applied to sephadex G-200 column for gel filtration chromatography. It was observed that enzyme achieved 59.37 U mg-1of specific activity with 27.08 fold purity and 64.36% recovery. Purified glucose oxidase was injected into rabbits through intravenous route, to raise the glucose oxidase antibodies. After 30 days incubation period, the rabbits were slaughtered and serum was separated from blood. The antibodies were isolated by ammonium sulfate precipitation and confirmed by agar gel precipitation test. This could be a convenient and low cost alternate assay for the estimation of glucose oxidase in biological fluids. Moreover, such antibodies against the said enzyme could be used in various therapeutic and diagnostic applications.

  7. Selective Biological Responses of Phagocytes and Lungs to Purified Histones.

    Fattahi, Fatemeh; Grailer, Jamison J; Lu, Hope; Dick, Rachel S; Parlett, Michella; Zetoune, Firas S; Nuñez, Gabriel; Ward, Peter A

    2017-01-01

    Histones invoke strong proinflammatory responses in many different organs and cells. We assessed biological responses to purified or recombinant histones, using human and murine phagocytes and mouse lungs. H1 had the strongest ability in vitro to induce cell swelling independent of requirements for toll-like receptors (TLRs) 2 or 4. These responses were also associated with lactate dehydrogenase release. H3 and H2B were the strongest inducers of [Ca2+]i elevations in phagocytes. Cytokine and chemokine release from mouse and human phagocytes was predominately a function of H2A and H2B. Double TLR2 and TLR4 knockout (KO) mice had dramatically reduced cytokine release induced in macrophages exposed to individual histones. In contrast, macrophages from single TLR-KO mice showed few inhibitory effects on cytokine production. Using the NLRP3 inflammasome protocol, release of mature IL-1β was predominantly a feature of H1. Acute lung injury following the airway delivery of histones suggested that H1, H2A, and H2B were linked to alveolar leak of albumin and the buildup of polymorphonuclear neutrophils as well as the release of chemokines and cytokines into bronchoalveolar fluids. These results demonstrate distinct biological roles for individual histones in the context of inflammation biology and the requirement of both TLR2 and TLR4. © 2017 S. Karger AG, Basel.

  8. Some properties of purified hepatoredoxin from bovine liver mitochondria

    Gilevich, S.N.; Gurev, O.L.; Shkumatov, V.M.; Chashchin, V.L.; Akhrem, A.A.

    1986-01-01

    Some of the most important physicochemical properties of hepatoredoxin from bovine liver, purified to a homogeneous state, were determined for the first time. The protein contains a [2Fe-2S] cluster in its active site and in an oxidized state has absorption maxima at 280, 320, 415, and 455 nm. The spectrophotometric index of purity (A 415 /A 280 ) of the homogeneous native preparation is 0.84; the extinction coefficient (epsilon 415 ) is equal to 9800 M -1 cm -1 . According to the data of gel electrophoresis in the presence of SDS, hepatoredoxin has an M/sub r/ of 12,500; its isoelectric point (pI) is equal to 4.2. Hepatoredoxin is necessary for the reconstitution of the C 27 -steroid hydroxylase activity and can be replaced by the related protein, adrenodoxin. All the parameters listed above, as well as the CD spectra, the immunochemical properties, and sequence of the first five N-terminal amino acids of hepatoredoxin and adrenodoxin are very similar of identical. At the same time, the amino acid composition of the two ferredoxins, along with common properties, has some differences

  9. PURIFIED WASTE FCC CATALYST AS A CEMENT REPLACEMENT MATERIAL

    Danute Vaiciukyniene

    2015-06-01

    Full Text Available Zeolites are commonly used in the fluid catalytic cracking process. Zeolite polluted with oil products and became waste after some time used. The quantity of this waste inevitably rises by expanding rapidly oil industry. The composition of these catalysts depends on the manufacturer and on the process that is going to be used. The main factors retarding hydration process of cement systems and modifying them strength are organic compounds impurities in the waste FCC catalyst. The present paper shows the results of using purified waste FCC catalyst (pFCC from Lithuania oil refinery, as Portland cement replacement material. For this purpose, the purification of waste FCC catalyst (FCC samples was treated with hydrogen peroxide. Hydrogen peroxide (H2O2 is one of the most powerful oxidizers known. By acting of waste with H2O2 it can eliminate the aforementioned waste deficiency, and the obtained product becomes one of the most promising ingredients, in new advanced building materials. Hardened cement paste samples with FCC or pFCC were formed. It was observed that the pFCC blended cements developed higher strength, after 28 days, compared to the samples with FCC or reference samples. Typical content of Portland cement substituting does not exceed 30 % of mass of Portland cement in samples. Reducing the consumption of Portland cement with utilizing waste materials is preferred for reasons of environmental protection.

  10. Hydrologic consistency as a basis for assessing complexity of monthly water balance models for the continental United States

    Martinez, Guillermo F.; Gupta, Hoshin V.

    2011-12-01

    Methods to select parsimonious and hydrologically consistent model structures are useful for evaluating dominance of hydrologic processes and representativeness of data. While information criteria (appropriately constrained to obey underlying statistical assumptions) can provide a basis for evaluating appropriate model complexity, it is not sufficient to rely upon the principle of maximum likelihood (ML) alone. We suggest that one must also call upon a "principle of hydrologic consistency," meaning that selected ML structures and parameter estimates must be constrained (as well as possible) to reproduce desired hydrological characteristics of the processes under investigation. This argument is demonstrated in the context of evaluating the suitability of candidate model structures for lumped water balance modeling across the continental United States, using data from 307 snow-free catchments. The models are constrained to satisfy several tests of hydrologic consistency, a flow space transformation is used to ensure better consistency with underlying statistical assumptions, and information criteria are used to evaluate model complexity relative to the data. The results clearly demonstrate that the principle of consistency provides a sensible basis for guiding selection of model structures and indicate strong spatial persistence of certain model structures across the continental United States. Further work to untangle reasons for model structure predominance can help to relate conceptual model structures to physical characteristics of the catchments, facilitating the task of prediction in ungaged basins.

  11. An outbreak of hospital-acquired Pseudomonas aeruginosa infection caused by contaminated bottled water in intensive care units.

    Eckmanns, T; Oppert, M; Martin, M; Amorosa, R; Zuschneid, I; Frei, U; Rüden, H; Weist, K

    2008-05-01

    This study describes an outbreak of Pseudomonas aeruginosa infections caused by contaminated bottled still water (BSW) in six intensive care units (ICUs) of a German university hospital. Clinical and environmental samples from these units were cultured and genotyped by amplified fragment-length polymorphism and pulsed-field gel electrophoresis analysis. Microbiological results were reviewed on a weekly basis to determine the number of P. aeruginosa infections and colonisations of ICU patients. Clinical specimens from 19 ICU patients--15 infections and four colonisations--yielded the same strain of P. aeruginosa. Furthermore, four of 103 environmental samples also yielded P. aeruginosa. However, only a P. aeruginosa strain isolated from unopened BSW was genetically identical to the P. aeruginosa strain isolated from the patients. In the 42-week period before the outbreak, the mean weekly number of new ICU patients infected or colonised with P. aeruginosa was 46.9 (95% CI 40.7-53.1)/1000 bed-days. During the 6-week period of the outbreak, the weekly number of new patients with P. aeruginosa was 88.9 (95% CI 54.3-122.2)/1000 bed-days. This number returned to the previous level after removal of the BSW. Thus, the microbiological and epidemiological findings revealed that the outbreak was related to BSW contaminated with P. aeruginosa. It was concluded that all untested BSW should be removed from ICUs.

  12. How Useful is Extravascular Lung Water Measurement in Managing Lung Injury in Intensive Care Unit?

    Bhattacharjee, Anirban; Pradhan, Debasis; Bhattacharyya, Prithwis; Dey, Samarjit; Chhunthang, Daniala; Handique, Akash; Barman, Angkita; Yunus, Mohd

    2017-08-01

    The primary goal of septic shock management is optimization of organ perfusion, often at the risk of overloading the interstitium and causing pulmonary edema. The conventionally used end points of resuscitation do not generally include volumetric parameters such as extravascular lung water index (EVLWI) and pulmonary vascular permeability index (PVPI). This study aimed to assess the prognostic value of EVLWI and PVPI by calculating their correlation with the severity of lung injury. This prospective observational study included twenty mechanically ventilated critically ill patients with Acute Physiology and Chronic Health Evaluation score (APACHE II) >20. EVLWI and PVPI were measured using transpulmonary thermodilution, and simultaneously, PaO 2 :FiO 2 ratio, alveolar-arterial gradient of oxygen (AaDO 2 ), and chest radiograph scores from two radiologists were obtained. The correlation of EVLWI and PVPI with chest radiograph scores, PaO 2 :FiO 2 ratio, and AaDO 2 were calculated. The inter-observer agreement between the two radiologists was tested using kappa test. EVLWI and PVPI correlated modestly with PaO 2 :FiO 2 ( r = -0.32, P = 0.0004; r = -0.39, P = 0.0001). There was a better correlation of EVLWI and PVPI with PaO 2 :FiO 2 ratio ( r = -0.71, P < 0.0001; r = -0.58, P = 0.0001) in the acute respiratory distress syndrome (ARDS) subgroup. The EVLWI values correlated significantly with corresponding chest radiograph scores ( r = 0.71, P < 0.0001 for observer 1 and r = 0.68, P < 0.0001 for observer 2). EVLWI and PVPI may have a prognostic significance in the assessment of lung injury in septic shock patients with ARDS. Further research is required to reveal the usefulness of EVLWI as an end point of fluid resuscitation in the management of septic shock with ARDS.

  13. [Decontamination of dental unit waterlines using disinfectants and filters].

    Monarca, S; Garusi, G; Gigola, P; Spampinato, L; Zani, C; Sapelli, P L

    2002-10-01

    Bacterial contamination of the dental unit water system can become a health problem for patients, particularly if they are immunodepressed. The present study has had the purpose of evaluating the effectiveness of methods of chemical decontamination using different disinfectants (peracetic acid, hydrogen peroxide, silver salts, chloramine T, glutaraldehyde T4) and methods of physical decontamination using synthetic membranes for the filtration of water. A preliminary removal procedure of the biofilm present in the waterline has been followed in a dental unit prepared on purpose for the research; subsequently different 2-week long maintenance procedures were applied using disinfectants injected by a pump and finally the bacterial contamination of the water flowing from the waterline was evaluated. The physical decontamination was performed using 0.22 mm membrane filters, which have been installed also in another dental unit, and the filtered water was analyzed to detect bacterial contamination. The preliminary procedure of biofilm removal succeeded obtaining germ-free water. Among the disinfectants used for the maintenance of the water quality only glutaraldehyde T4 was able to reduce the bacterial contamination under the limit suggested by the ADA. The membrane filter system was not able to purify the water, but when a disinfectant (peracetic acid) was used in the last part of the waterline good results were obtained. At present no decontamination system of dental waterline is available, and glutaraldehyde T4 seems to be the best disinfectant only if integrated with periodic biofilm removal for the maintenance of the water quality.

  14. Ground-water hydrology and simulation of ground-water flow at Operable Unit 3 and surrounding region, U.S. Naval Air Station, Jacksonville, Florida

    Davis, J.H.

    1998-01-01

    The Naval Air Station, Jacksonville (herein referred to as the Station), occupies 3,800 acres adjacent to the St. Johns River in Duval County, Florida. Operable Unit 3 (OU3) occupies 134 acres on the eastern side of the Station and has been used for industrial and commercial purposes since World War II. Ground water contaminated by chlorinated organic compounds has been detected in the surficial aquifer at OU3. The U.S. Navy and U.S. Geological Survey (USGS) conducted a cooperative hydrologic study to evaluate the potential for ground water discharge to the neighboring St. Johns River. A ground-water flow model, previously developed for the area, was recalibrated for use in this study. At the Station, the surficial aquifer is exposed at land surface and forms the uppermost permeable unit. The aquifer ranges in thickness from 30 to 100 feet and consists of unconsolidated silty sands interbedded with local beds of clay. The low-permeability clays of the Hawthorn Group form the base of the aquifer. The USGS previously conducted a ground-water investigation at the Station that included the development and calibration of a 1-layer regional ground-water flow model. For this investigation, the regional model was recalibrated using additional data collected after the original calibration. The recalibrated model was then used to establish the boundaries for a smaller subregional model roughly centered on OU3. Within the subregional model, the surficial aquifer is composed of distinct upper and intermediate layers. The upper layer extends from land surface to a depth of approximately 15 feet below sea level; the intermediate layer extends from the upper layer down to the top of the Hawthorn Group. In the northern and central parts of OU3, the upper and intermediate layers are separated by a low-permeability clay layer. Horizontal hydraulic conductivities in the upper layer, determined from aquifer tests, range from 0.19 to 3.8 feet per day. The horizontal hydraulic

  15. Grey water treatment by a continuous process of an electrocoagulation unit and a submerged membrane bioreactor system

    Bani-Melhem, Khalid

    2012-08-01

    This paper presents the performance of an integrated process consisting of an electro-coagulation (EC) unit and a submerged membrane bioreactor (SMBR) technology for grey water treatment. For comparison purposes, another SMBR process without electrocoagulation (EC) was operated in parallel with both processes operated under constant transmembrane pressure for 24. days in continuous operation mode. It was found that integrating EC process with SMBR (EC-SMBR) was not only an effective method for grey water treatment but also for improving the overall performance of the membrane filtration process. EC-SMBR process achieved up to 13% reduction in membrane fouling compared to SMBR without electrocoagulation. High average percent removals were attained by both processes for most wastewater parameters studied. The results demonstrated that EC-SMBR performance slightly exceeded that of SMBR for COD, turbidity, and colour. Both processes produced effluent free of suspended solids, and faecal coliforms were nearly (100%) removed in both processes. A substantial improvement was achieved in removal of phosphate in the EC-SMBR process. However, ammonia nitrogen was removed more effectively by the SMBR only. Accordingly, the electrolysis condition in the EC-SMBR process should be optimized so as not to impede biological treatment. © 2012 Elsevier B.V.

  16. Deep-water chaunacid and lophiid anglerfishes (Pisces: Lophiiformes) off the south-eastern United States

    Caruso, John H.; Ross, Steve W.; Sulak, K.J.; Sedberry, G.R.

    2007-01-01

    were noted. In particular, L. beroe displayed a characteristic pattern of white patches in life that were not apparent after death. The first photographic documentation of the colour pattern in life and of the pharyngeal pigmentation of Lophiodes reticulatus is provided. The third known specimen of Sladenia shaefersi, and the first to be taken in U.S. waters was collected from coral rubble near the base of a steep 200 m scarp on the Blake Plateau. ?? 2007 The Fisheries Society of the British Isles.

  17. Deep-water chaunacid and lophiid anglerfishes (Pisces: Lophiiformes) off the Southeastern United States

    Caruso, John H.; Ross, Steve W.; Sulak, Kenneth J.; Sedberry, George R.

    2007-01-01

    patterns of both species were noted. In particular, L. beroe displayed a characteristic pattern of white patches in life that were not apparent after death. The first photographic documentation of the colour pattern in life and of the pharyngeal pigmentation of Lophiodes reticulatus is provided. The third known specimen of Sladenia shaefersi, and the first to be taken in U.S. waters was collected from coral rubble near the base of a steep 200 m scarp on the Blake Plateau.

  18. Creating potentiometric surfaces from combined water well and oil well data in the midcontinent of the United States

    Gianoutsos, Nicholas J.; Nelson, Philip H.

    2013-01-01

    For years, hydrologists have defined potentiometric surfaces using measured hydraulic-head values in water wells from aquifers. Down-dip, the oil and gas industry is also interested in the formation pressures of many of the same geologic formations for the purpose of hydrocarbon recovery. In oil and gas exploration, drillstem tests (DSTs) provide the formation pressure for a given depth interval in a well. These DST measurements can be used to calculate hydraulic-head values in deep hydrocarbon-bearing formations in areas where water wells do not exist. Unlike hydraulic-head measurements in water wells, which have a low number of problematic data points (outliers), only a small subset of the DST data measure true formation pressures. Using 3D imaging capabilities to view and clean the data, we have developed a process to estimate potentiometric surfaces from erratic DST data sets of hydrocarbon-bearing formations in the midcontinent of the U.S. The analysis indicates that the potentiometric surface is more readily defined through human interpretation of the chaotic DST data sets rather than through the application of filtering and geostatistical analysis. The data are viewed as a series of narrow, 400-mile-long swaths and a 2D viewer is used to select a subset of hydraulic-head values that represent the potentiometric surface. The user-selected subsets for each swath are then combined into one data set for each formation. These data are then joined with the hydraulic-head values from water wells to define the 3D potentiometric surfaces. The final product is an interactive, 3D digital display containing: (1) the subsurface structure of the formation, (2) the cluster of DST-derived hydraulic head values, (3) the user-selected subset of hydraulic-head values that define the potentiometric surface, (4) the hydraulic-head measurements from the corresponding shallow aquifer, (5) the resulting potentiometric surface encompassing both oil and gas and water wells, and (6

  19. Pesticides in streams of the United States : initial results from the National Water-Quality Assessment Program

    Larson, Steven J.; Gilliom, Robert J.; Capel, Paul D.

    1999-01-01

    Water samples from 58 rivers and streams across the United States were analyzed for pesticides as part of the National Water-Quality Assessment Program of the U.S. Geological Survey. The sampling sites represent 37 diverse agricultural basins, 11 urban basins, and 10 basins with mixed land use. Forty-six pesticides and pesticide degradation products were analyzed in approximately 2,200 samples collected from 1992 to 1995. The target compounds account for approximately 70 percent of national agricultural use in terms of the mass of pesticides applied annually. All the target compounds were detected in one or more samples. Herbicides generally were detected more frequently and at higher concentrations than insecticides. Nationally, 11 herbicides, 1 herbicide degradation product, and 3 insecticides were detected in more than 10 percent of samples. The number of target compounds detected at each site ranged from 7 to 37. The herbicides atrazine, metolachlor, prometon, and simazine were detected most frequently; among the insecticides, carbaryl, chlorpyrifos, and diazinon were detected the most frequently. Distinct differences in pesticide occurrence were observed in streams draining the various agricultural settings. Relatively high levels of several herbicides occurred as seasonal pulses in corn-growing areas. Several insecticides were frequently detected in areas where the dominant crops consist of orchards and vegetables. The number of pesticides detected and their concentrations were lower in wheat-growing areas than in most other agricultural areas. In most urban areas, the herbicides prometon and simazine and the insecticides carbaryl, chlorpyrifos, diazinon, and malathion were commonly detected. Concentrations of pesticides rarely exceeded standards and criteria established for drinking water, but some pesticides commonly exceeded criteria established for the protection of aquatic life.

  20. Point sources of emerging contaminants along the Colorado River Basin: Source water for the arid Southwestern United States

    Jones-Lepp, Tammy L.; Sanchez, Charles; Alvarez, David A.; Wilson, Doyle C.; Taniguchi-Fu, Randi-Laurant

    2012-01-01

    Emerging contaminants (ECs) (e.g., pharmaceuticals, illicit drugs, personal care products) have been detected in waters across the United States. The objective of this study was to evaluate point sources of ECs along the Colorado River, from the headwaters in Colorado to the Gulf of California. At selected locations in the Colorado River Basin (sites in Colorado, Utah, Nevada, Arizona, and California), waste stream tributaries and receiving surface waters were sampled using either grab sampling or polar organic chemical integrative samplers (POCIS). The grab samples were extracted using solid-phase cartridge extraction (SPE), and the POCIS sorbents were transferred into empty SPEs and eluted with methanol. All extracts were prepared for, and analyzed by, liquid chromatography–electrospray-ion trap mass spectrometry (LC–ESI-ITMS). Log DOW values were calculated for all ECs in the study and compared to the empirical data collected. POCIS extracts were screened for the presence of estrogenic chemicals using the yeast estrogen screen (YES) assay. Extracts from the 2008 POCIS deployment in the Las Vegas Wash showed the second highest estrogenicity response. In the grab samples, azithromycin (an antibiotic) was detected in all but one urban waste stream, with concentrations ranging from 30 ng/L to 2800 ng/L. Concentration levels of azithromycin, methamphetamine and pseudoephedrine showed temporal variation from the Tucson WWTP. Those ECs that were detected in the main surface water channels (those that are diverted for urban use and irrigation along the Colorado River) were in the region of the limit-of-detection (e.g., 10 ng/L), but most were below detection limits.