  1. Drop performance test and evaluation for HANARO shutoff units

    International Nuclear Information System (INIS)

    Jung, Y. H.; Cho, Y. K.; Lee, J. H.; Choi, Y. S.; Woo, J. S.

    2004-01-01

    The function of the shutoff units of the HANARO is to rapidly insert the shutoff rod into the reactor core for safe shutdown of reactor. This paper describes drop performance test and evaluation for a shutoff unit for the technical verification of lifetime extension and localization of the HANARO shutoff units. We have performed preliminary drop performance tests for a shutoff unit at 1/2-core test loop and analyzed through the comparison with the test results performed during design verification test and the results of the periodic performance test in HANARO. It shows that the results of the local fabrication, installation and alignment for the shutoff unit meet the basic performance requirements, Furthermore, the performance evaluation method of the periodic drop test of the HANARO shutoff units is a conservative method comparing with the real drop time

  2. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, Christopher G.

    2008-01-01

    The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11. Now in it's fourth edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Laboratory Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by U.S. Nuclear Regulatory Commission (NRC) regulations. The U.S. Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). One of the goals of this current revision was the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to U.S. personal dosemeter performance testing. The testing philosophy of ANSI/HPS N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. In this paper, the history of performance testing in the U.S. is briefly reviewed. Also described is the revision that produced the fourth edition of this standard, which has taken place over the last three years (2005-2008) by a working group representing national standards laboratories, government laboratories, the military, dosimetry vendors, universities and the nuclear power industry. (author)

  3. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, C.G.

    2005-01-01

    Full text: The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11 (2002). Now in its third edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by US Nuclear Regulatory Commission (NRC) regulations. The US Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). A focus in recent years has been the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to US personal dosimeter processing testing. The testing philosophy of ANSI N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. This unique philosophy is explored in detail in this presentation, along with trends in the development of the document to its present state. In addition, a look will be taken at what the future holds for the next revision of the document, scheduled to begin in 2005. (author)

  4. Performance and Environmental Test Results of the High Voltage Hall Accelerator Engineering Development Unit

    Science.gov (United States)

    Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Shastry, Rohit; Pinero, Luis; Peterson, Todd; Mathers, Alex

    2012-01-01

    NASA Science Mission Directorate's In-Space Propulsion Technology Program is sponsoring the development of a 3.5 kW-class engineering development unit Hall thruster for implementation in NASA science and exploration missions. NASA Glenn and Aerojet are developing a high fidelity high voltage Hall accelerator that can achieve specific impulse magnitudes greater than 2,700 seconds and xenon throughput capability in excess of 300 kilograms. Performance, plume mappings, thermal characterization, and vibration tests of the high voltage Hall accelerator engineering development unit have been performed. Performance test results indicated that at 3.9 kW the thruster achieved a total thrust efficiency and specific impulse of 58%, and 2,700 sec, respectively. Thermal characterization tests indicated that the thruster component temperatures were within the prescribed material maximum operating temperature limits during full power thruster operation. Finally, thruster vibration tests indicated that the thruster survived the 3-axes qualification full-level random vibration test series. Pre and post-vibration test performance mappings indicated almost identical thruster performance. Finally, an update on the development progress of a power processing unit and a xenon feed system is provided.

  5. Software development for simplified performance tests and weekly performance check in Younggwang NPP Unit 3 and 4

    International Nuclear Information System (INIS)

    Hur, K. Y.; Jang, S. H.; Lee, J. W.; Kim, J. T.; Park, J. C.

    2002-01-01

    This paper covers the current status of turbine cycle performance test in nuclear power plants and the software development which can solve some shortcomings related to performance tests. The software developed is for simplified performance tests and weekly performance checks in Yonggwang nuclear power plant unit 3 and 4. This software includes the requirements from the efficiency division for the consistency with actual performance analysis work and the usability of the collected performance test data. From the working survey, we identify the difference between the embedded performance analysis modules and the actual performance analysis work. This software helps operation or maintenance personnel to reduce work load, to support the trend analysis of essential parameters in a turbine cycle, and to utilize the correction curves for the decision-making in their work

  6. History of personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, C. G.

    2007-01-01

    The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11 (2001). Now in its third edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by US Nuclear Regulatory Commission (NRC) regulations. The US Dept. of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Dept. of Energy Laboratory Accreditation Program (DOELAP). A focus in recent years has been the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonisation to US personal dosemeter processing testing. Since there is no type testing program in the US for personal dosemeters, the testing philosophy of ANSI N13.11 has always combined elements of type testing and routine performance testing. This philosophy is explored in detail in this presentation, along with trends in the development of the document to its present state. In addition, a look will be taken at what the future holds for the next revision of the document, scheduled to begin in 2005. (authors)

  7. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2

    Science.gov (United States)

    Platt, R.

    1999-01-01

    This is the Performance Verification Report, Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The specification establishes the requirements for the Comprehensive Performance Test (CPT) and Limited Performance Test (LPT) of the Advanced Microwave Sounding, Unit-A2 (AMSU-A2), referred to herein as the unit. The unit is defined on Drawing 1331200. 1.2 Test procedure sequence. The sequence in which the several phases of this test procedure shall take place is shown in Figure 1, but the sequence can be in any order.

  8. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Reports: Final Comprehensive Performance Test Report, P/N: 1356006-1, S.N: 202/A2

    Science.gov (United States)

    Platt, R.

    1998-01-01

    This is the Performance Verification Report. the process specification establishes the requirements for the comprehensive performance test (CPT) and limited performance test (LPT) of the earth observing system advanced microwave sounding unit-A2 (EOS/AMSU-A2), referred to as the unit. The unit is defined on drawing 1356006.

  9. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Final Comprehensive Performance Test Report, P/N 1331720-2TST, S/N 105/A1

    Science.gov (United States)

    Platt, R.

    1999-01-01

    This is the Performance Verification Report, Final Comprehensive Performance Test (CPT) Report, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). This specification establishes the requirements for the CPT and Limited Performance Test (LPT) of the AMSU-1A, referred to here in as the unit. The sequence in which the several phases of this test procedure shall take place is shown.

  10. 40 CFR 63.9620 - On which units and by what date must I conduct performance tests or other initial compliance...

    Science.gov (United States)

    2010-07-01

    ... units and by what date must I conduct performance tests or other initial compliance demonstrations? (a... similar emission units together and conduct an initial compliance test on one representative emission unit... meet the criteria in paragraph (f) of this section. If you decide to test representative emission units...

  11. Statistical modeling of dental unit water bacterial test kit performance.

    Science.gov (United States)

    Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E

    2007-01-01

    While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.

  12. The operating performance tests of power unit A1 in HPP 'Zvornik' in load-frequency control

    Directory of Open Access Journals (Sweden)

    Stanojčić Vladimir

    2012-01-01

    Full Text Available The turbine-governing system characteristics derived from testing hydropower unit A1 in HPP 'Zvornik' are presented. These tests give insights into the setup state and parameters of the governing system, as well as the qualitative analysis of load-frequency control response of the case study power unit within the power system of Serbia. Verification of relevant turbine-governing parameters was performed by direct application of appropriate standards and policies. The presented results can be used as a basis for the derivation of a turbine governor mathematical model and for a complete mathematical model of a hydropower unit as an element embedded in the power system.

  13. Radioactive material packaging performance testing

    International Nuclear Information System (INIS)

    Romano, T.; Cruse, J.M.

    1991-02-01

    To provide uniform packaging of hazardous materials on an international level, the United Nations has developed packaging recommendations that have been implemented worldwide. The United Nations packaging recommendations are performance oriented, allowing for a wide variety of package materials and systems. As a result of this international standard, efforts in the United States are being directed toward use of performance-oriented packaging and elimination of specification (designed) packaging. This presentation will focus on trends, design evaluation, and performance testing of radioactive material packaging. The impacts of US Department of Transportation Dockets HM-181 and HM-169A on specification and low-specific activity radioactive material packaging requirements are briefly discussed. The US Department of Energy's program for evaluating radioactive material packings per US Department of Transportation Specification 7A Type A requirements, is used as the basis for discussing low-activity packaging performance test requirements. High-activity package testing requirements are presented with examples of testing performed at the Hanford Site that is operated by Westinghouse Hanford Company for the US Department of Energy. 5 refs., 2 tabs

  14. Simulation Analysis as a Way to Assess the Performance of Important Unit Root and Change in Persistence Tests

    DEFF Research Database (Denmark)

    Fernández, Raúl O.; Vera-Valdés, J. Eduardo

    2013-01-01

    This chapter shows a way to, using simulation analysis, assess the performance of some of the most popular unit root and change in persistence tests. The authors do this by means of Monte Carlo simulations. The findings suggest that these tests show a lower than expected performance when dealing ...

  15. Performance test of the prototype-unit for J-PARC machine protection system

    International Nuclear Information System (INIS)

    Sakaki, Hironao; Nakamura, Naoki; Takahashi, Hiroki; Yoshikawa, Hiroshi

    2004-03-01

    In High Intensity Proton Accelerator Project (J-PARC), the high-power proton beam is accelerated. If the beam in J-PARC is not stopped at a few micro seconds or less, the fatal thermal shock destruction is caused on the surface of accelerating structure, because of the high-power proton beam. To avoid the thermal shock damage, we designed the high-speed machine protection system. And, the prototype unit for the system was produced. This report shows the result of its performance test. (author)

  16. Development of turbopump cavitation performance test facility and the test of inducer performance

    International Nuclear Information System (INIS)

    Sohn, Dong Kee; Kim, Chun Tak; Yoon, Min Soo; Cha, Bong Jun; Kim, Jin Han; Yang, Soo Seok

    2001-01-01

    A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar, rotational speed - 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification

  17. High Power Alternator Test Unit (ATU) Electrical System Test

    Science.gov (United States)

    Birchenough, Arthur; Hervol, David

    2007-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was used to simulate the operating conditions and evaluate the performance of the ATU and it s interaction with various LPSF components in accordance with the JIMO AC Power System Requirements. The testing was carried out at the breadboard development level. Results of these tests will be used for the development and validation of analytical models for performance and lifetime prediction.

  18. A Unit-Test Framework for Database Applications

    DEFF Research Database (Denmark)

    Christensen, Claus Abildgaard; Gundersborg, Steen; de Linde, Kristian

    The outcome of a test of an application that stores data in a database naturally depends on the state of the database. It is therefore important that test developers are able to set up and tear down database states in a simple and efficient manner. In existing unit-test frameworks, setting up...... test can be minimized. In addition, the reuse between unit tests can speed up the execution of test suites. A performance test on a medium-size project shows a 40% speed up and an estimated 25% reduction in the number of lines of test code....

  19. Extra-regulatory impact tests and analyses of the structural evaluation test unit

    International Nuclear Information System (INIS)

    Ludwigsen, J.S.; Ammerman, D.J.

    1995-01-01

    The structural evaluation test unit is roughly equivalent to a 1/3 scale model of a high level waste rail cask. The test unit was designed to just meet the requirements of NRC Regulatory Guide 7.6 when subjected to a 9 m (30 ft) free drop resulting in an impact velocity of 13.4 m/s (30 mph) onto an unyielding target in the end-on orientation. The test unit was then subjected to impacts with higher velocities to determine the amount of built-in conservatism in this design approach. Test impacts of 13.4, 20.1 and 26.8 m/s (30, 45, and 60 mph) were performed. This paper will describe the design, testing, and comparison of measured strains and deformations to the equivalent analytical predictions

  20. A New Symmetrical Unit for Breakwater Armour : First Tests

    NARCIS (Netherlands)

    Salauddin, M.; Broere, A.; Van der Meer, J.W.; Verhagen, H.J.; Bijl, E.

    2015-01-01

    A new and symmetrical single layer armour unit, the crablock, has been designed in the UAE. One breakwater was reconstructed with crablock, but very limited testing had been performed. Just to become more acquainted with this new unit, pre-competitive research at a university has been performed,

  1. Quick setup of test unit for accelerator control system

    International Nuclear Information System (INIS)

    Fu, W.; D'Ottavio, T.; Gassner, D.; Nemesure, S.; Morris, J.

    2011-01-01

    Testing a single hardware unit of an accelerator control system often requires the setup of a program with graphical user interface. Developing a dedicated application for a specific hardware unit test could be time consuming and the application may become obsolete after the unit tests. This paper documents a methodology for quick design and setup of an interface focused on performing unit tests of accelerator equipment with minimum programming work. The method has three components. The first is a generic accelerator device object (ADO) manager which can be used to setup, store, and log testing controls parameters for any unit testing system. The second involves the design of a TAPE (Tool for Automated Procedure Execution) sequence file that specifies and implements all te testing and control logic. The sting third is the design of a PET (parameter editing tool) page that provides the unit tester with all the necessary control parameters required for testing. This approach has been used for testing the horizontal plane of the Stochastic Cooling Motion Control System at RHIC.

  2. Out-pile test plan for lifetime extension of shutoff units in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Joe, Y. G.; Lee, J. H.; Jeong, Y. H.; Woo, S. I.; Ryu, J. S.; Kim, Y. G.; Park, Y. C.; Kim, H. G.; Woo, J. S. [KAERI, Taejon (Korea, Republic of)

    2003-10-01

    It is estimated that the number of drops of shutoff rods in HANARO will reach the endurance verified numbers before the end of the reactor life. To resolve this situation, we have a plan to prepare of a new spare unit by the performance verification test for the local product, and extend the lifetime of shutoff units installed in the reactor by performing an additional endurance test in the out-pile test facility using an existing spare unit. This paper describes the overall situations and test plan for the out-pile test to extend the lifetime extension of shutoff unit.

  3. 40 CFR Table 18 to Subpart Uuu of... - Requirements for Performance Tests for Organic HAP Emissions From Catalytic Reforming Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Requirements for Performance Tests for Organic HAP Emissions From Catalytic Reforming Units 18 Table 18 to Subpart UUU of Part 63 Protection of... for Organic HAP Emissions From Catalytic Reforming Units As stated in § 63.1566(b)(2) and (3), you...

  4. Where Lab Tests Are Performed

    Science.gov (United States)

    ... example, there may be sections that focus on microbiology, hematology, chemistry, and blood banking . Other units may perform highly specialized tests using electron microscopy and immunohistochemistry, and still others ...

  5. The performance testing

    International Nuclear Information System (INIS)

    Mayr, A.

    1975-01-01

    Concerning the time-schedule of reactor performance tests they normally begin when suppliers or constructors have finished construction and made all necessary construction and coordinated tests. If the last-mentioned tests are conducted profoundly, they contribute substantially to a quick and simple carrying-out of the last performance tests and to the general quality of components and systems. At this stage all components of a system should be properly fixed, machinery, instruments and electrical components adjusted and calibrated, all set-points tested, electrical and other supply units in operation or ready to operate and all functions pretested. Just at this stage of the work most of the existing defects and failures of systems can be found. Remembering the fact that the difficulty of operation of complex systems results from detail problems, it is extremely useful to remove all things of this kind as soon as possible, at the latest at this time where it is done easily and normally quickly without influencing start-up-procedures of other systems or even of the total plant. (orig./TK) [de

  6. Discrete Optimization of Internal Part Structure via SLM Unit Structure-Performance Database

    Directory of Open Access Journals (Sweden)

    Li Tang

    2018-01-01

    Full Text Available The structural optimization of the internal structure of parts based on three-dimensional (3D printing has been recognized as being important in the field of mechanical design. The purpose of this paper is to present a creation of a unit structure-performance database based on the selective laser melting (SLM, which contains various structural units with different functions and records their structure and performance characteristics so that we can optimize the internal structure of parts directly, according to the database. The method of creating the unit structure-performance database was introduced in this paper and several structural units of the unit structure-performance database were introduced. The bow structure unit was used to show how to create the structure-performance database of the unit as an example. Some samples of the bow structure unit were designed and manufactured by SLM. These samples were tested in the WDW-100 compression testing machine to obtain their performance characteristics. After this, the paper collected all data regarding unit structure parameters, weight, performance characteristics, and other data; and, established a complete set of data from the bow structure unit for the unit structure-performance database. Furthermore, an aircraft part was reconstructed conveniently to be more lightweight according to the unit structure-performance database. Its weight was reduced by 36.8% when compared with the original structure, while the strength far exceeded the requirements.

  7. Gamma-ray shielding design and performance test of WASTEF

    International Nuclear Information System (INIS)

    Matsumoto, Seiichiro; Aoyama, Saburo; Tashiro, Shingo; Nagai, Shiro

    1984-06-01

    The Waste Safety Testing Facility (WASTEF) was planned in 1978 to test the safety performance of HLW vitrified forms under the simulated conditions of long term storage and disposal, and completed in August 1981. The designed feature of the facility is to treat the vitrified forms contain actual high-level wastes of 5 x 10 4 Ci in maximum with 5 units of concrete shilded hot cells (3 units : Bate-Gamma cells, 2 units : Alpha-Gamma cells) and one units of Alpha-Gamma lead shielded cell, and to store radioactivity of 10 6 Ci in maximum. The safety performance of this facility is fundamentally maintained with confinement of radioactivity and shielding of the radiation. This report describes the method of gamma-ray shielding design, evaluation of the shielding test performed by using sealded gamma-ray sources(Co-60). (author)

  8. Temelin 1000 MW Units active testing stage - commissioning experience

    International Nuclear Information System (INIS)

    Ubra, O.; Riha, V.

    2003-01-01

    There were three basic stages of the NPP Temelin Units active testing stage- The zero and low power testing, The power ascension testing and Plant Performance Test. The main objective of the start- up process stages and the testing procedures including some operational experience are described in the paper. (author)

  9. Simulation-based evaluation of the performance of the F test in a linear multilevel model setting with sparseness at the level of the primary unit.

    Science.gov (United States)

    Bruyndonckx, Robin; Aerts, Marc; Hens, Niel

    2016-09-01

    In a linear multilevel model, significance of all fixed effects can be determined using F tests under maximum likelihood (ML) or restricted maximum likelihood (REML). In this paper, we demonstrate that in the presence of primary unit sparseness, the performance of the F test under both REML and ML is rather poor. Using simulations based on the structure of a data example on ceftriaxone consumption in hospitalized children, we studied variability, type I error rate and power in scenarios with a varying number of secondary units within the primary units. In general, the variability in the estimates for the effect of the primary unit decreased as the number of secondary units increased. In the presence of singletons (i.e., only one secondary unit within a primary unit), REML consistently outperformed ML, although even under REML the performance of the F test was found inadequate. When modeling the primary unit as a random effect, the power was lower while the type I error rate was unstable. The options of dropping, regrouping, or splitting the singletons could solve either the problem of a high type I error rate or a low power, while worsening the other. The permutation test appeared to be a valid alternative as it outperformed the F test, especially under REML. We conclude that in the presence of singletons, one should be careful in using the F test to determine the significance of the fixed effects, and propose the permutation test (under REML) as an alternative. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Technique for unit testing of safety software verification and validation

    International Nuclear Information System (INIS)

    Li Duo; Zhang Liangju; Feng Junting

    2008-01-01

    The key issue arising from digitalization of the reactor protection system for nuclear power plant is how to carry out verification and validation (V and V), to demonstrate and confirm the software that performs reactor safety functions is safe and reliable. One of the most important processes for software V and V is unit testing, which verifies and validates the software coding based on concept design for consistency, correctness and completeness during software development. The paper shows a preliminary study on the technique for unit testing of safety software V and V, focusing on such aspects as how to confirm test completeness, how to establish test platform, how to develop test cases and how to carry out unit testing. The technique discussed here was successfully used in the work of unit testing on safety software of a digital reactor protection system. (authors)

  11. Control room habitability Analysis and Testing for Wolsong Unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. B. [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    In response to this recommendation, KHNP has established CRH program and performed tracer gas in leakage tests. These activities are described herein including the emergency ventilation system analysis, acceptance criteria calculation for the test and Control Room Envelope (CRE) discrimination, and the results of the tracer gas tests are presented. CRH analysis including unfiltered in leakage tests according to the methodology in ASTM E741 was performed for Wolsong Unit 1. The results show that the integrity of the control room of Wolsong Unit 1 is in good condition to maintain the reactor in a safe condition under accident conditions, which complies with the US NRC regulatory guides 1.78, 1.196 and 1.197.

  12. A simple nonstationary-volatility robust panel unit root test

    NARCIS (Netherlands)

    Demetrescu, Matei; Hanck, Christoph

    2012-01-01

    We propose an IV panel unit root test robust to nonstationary error volatility. Its finite-sample performance is convincing even for many units and strong cross-correlation. An application to GDP prices illustrates the inferential impact of nonstationary volatility. (C) 2012 Elsevier B.V. All rights

  13. Charge-Control Unit for Testing Lithium-Ion Cells

    Science.gov (United States)

    Reid, Concha M.; Mazo, Michelle A.; Button, Robert M.

    2008-01-01

    A charge-control unit was developed as part of a program to validate Li-ion cells packaged together in batteries for aerospace use. The lithium-ion cell charge-control unit will be useful to anyone who performs testing of battery cells for aerospace and non-aerospace uses and to anyone who manufacturers battery test equipment. This technology reduces the quantity of costly power supplies and independent channels that are needed for test programs in which multiple cells are tested. Battery test equipment manufacturers can integrate the technology into their battery test equipment as a method to manage charging of multiple cells in series. The unit manages a complex scheme that is required for charging Li-ion cells electrically connected in series. The unit makes it possible to evaluate cells together as a pack using a single primary test channel, while also making it possible to charge each cell individually. Hence, inherent cell-to-cell variations in a series string of cells can be addressed, and yet the cost of testing is reduced substantially below the cost of testing each cell as a separate entity. The unit consists of electronic circuits and thermal-management devices housed in a common package. It also includes isolated annunciators to signal when the cells are being actively bypassed. These annunciators can be used by external charge managers or can be connected in series to signal that all cells have reached maximum charge. The charge-control circuitry for each cell amounts to regulator circuitry and is powered by that cell, eliminating the need for an external power source or controller. A 110-VAC source of electricity is required to power the thermal-management portion of the unit. A small direct-current source can be used to supply power for an annunciator signal, if desired.

  14. Development of a system for automatic control and performance evaluation of shutoff units in HANARO

    International Nuclear Information System (INIS)

    Jeong, Y. H.; Joe, Y. G.; Choi, Y. S.; Woo, J. S.

    2003-01-01

    The function of the shutoff units is to rapidly insert the shutoff rod into the reactor core for safe shutdown of reactor. This paper describes the development of a system for automatic control and performance evaluation of shutoff units. The system automatically drives the shutoff unit with a specified operation cycle and records the performance of the drive mechanism in graphs and data. Also, it records the operating parameters of the shutoff unit and test facility. The characteristic of the developed system was evaluated to compare with that being use in the HANARO reactor. The system will be used for the performance and endurance tests in the test facility. Hereafter, the system will efficiently be used for the normal operation and the periodical drop performance tests of shutoff units in HANARO

  15. Survey of regulatory agency review of generating unit performance

    International Nuclear Information System (INIS)

    Roach, E.M. Jr.; Tarletz, D.B.

    1985-01-01

    Regulatory agencies across the country are being called upon increasingly to monitor the management of electric utilities. Such activity, which once was relatively rare, is now common. Most frequently this oversight centers around the operating performance of generating units, both nuclear and fossil. There are, perhaps, several reasons for this increased interest in the efficient operation of generating units: increased fuel costs and fuel cost differentials, increased lead times and costs for construction of new generating units, and increased dependence on existing units because of construction programs being revised to meet decreased load growth. The monitoring of generating units has taken the form of after the fact evaluation of performance on a case-by-case basis and the implementation of productivity incentive programs. Performance standards are used in these contexts both to measure the adequacy of unit performance and to implement incentives in the form of rewards or penalties. The standard used may be a subjective test of prudent performance or some numerical index of plant performance, e.g., equivalent availability, capacity factor or heat rate. Some of the activity by regulators is reviewed in applying subjective and numerical standards and the considerations involved in applying such standards are discussed

  16. 1.8 K Refrigeration Units for the LHC: Performance Assessment of Pre-series Units

    CERN Document Server

    Claudet, S; Millet, F; Tavian, L; 20th International Cryogenic Engineering Conference (ICEC20)

    2005-01-01

    The cooling capacity below 2 K for the superconducting magnets of the Large Hadron Collider (LHC), at CERN, will be provided by eight refrigeration units of 2400 W at 1.8 K, each of them coupled to a 4.5 K refrigerator. The two selected vendors have proposed cycles based on centrifugal cold compressors combined with volumetric screw compressors with sub-atmospheric suction, as previously identified by CERN as “reference cycle”. The supply of the series units was linked to successful testing and acceptance of the pre-series temporarily installed in a dedicated test station. The global capacity, the performance of cold compressors and some process specificities have been thoroughly tested and will be presented.

  17. Apollo telescope mount thermal systems unit thermal vacuum test

    Science.gov (United States)

    Trucks, H. F.; Hueter, U.; Wise, J. H.; Bachtel, F. D.

    1971-01-01

    The Apollo Telescope Mount's thermal systems unit was utilized to conduct a full-scale thermal vacuum test to verify the thermal design and the analytical techniques used to develop the thermal mathematical models. Thermal vacuum test philosophy, test objectives configuration, test monitoring, environment simulation, vehicle test performance, and data correlation are discussed. Emphasis is placed on planning and execution of the thermal vacuum test with particular attention on problems encountered in conducting a test of this maguitude.

  18. Panel Unit Root Tests by Combining Dependent Values: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Xuguang Sheng

    2011-01-01

    Full Text Available We conduct a systematic comparison of the performance of four commonly used value combination methods applied to panel unit root tests: the original Fisher test, the modified inverse normal method, Simes test, and the modified truncated product method (TPM. Our simulation results show that under cross-section dependence the original Fisher test is severely oversized, but the other three tests exhibit good size properties. Simes test is powerful when the total evidence against the joint null hypothesis is concentrated in one or very few of the tests being combined, but the modified inverse normal method and the modified TPM have good performance when evidence against the joint null is spread among more than a small fraction of the panel units. These differences are further illustrated through one empirical example on testing purchasing power parity using a panel of OECD quarterly real exchange rates.

  19. Practical unit testing with JUnit and Mockito

    CERN Document Server

    Kaczanowski, Tomek

    2013-01-01

    This book explains in detail how to implement unit tests using two very popular open source Java technologies: JUnit and Mockito. It presents a range of techniques necessary to write high quality unit tests - e.g. mocks, parametrized tests and matchers. It also discusses trade-offs related to the choices we have to make when dealing with some real-life code issues. The book stresses the importance of writing readable and maintainable unit tests, and puts a lot of stress on code quality. It shows how to achieve testable code and to eliminate common mistakes by following the Test Driven Development approach. Every topic discussed in the book is illustrated with code examples, and each chapter is accompanied by some exercises. By reading this book you will: Grasp the role and purpose of unit tests Write high-quality, readable and maintainable unit tests Learn how to use JUnit and Mockito (but also other useful tools) Avoid common pitfalls when writing unit tests Recognize bad unit tests, a...

  20. CIT photoheliograph functional verification unit test program

    Science.gov (United States)

    1973-01-01

    Tests of the 2/3-meter photoheliograph functional verification unit FVU were performed with the FVU installed in its Big Bear Solar Observatory vacuum chamber. Interferometric tests were run both in Newtonian (f/3.85) and Gregorian (f/50) configurations. Tests were run in both configurations with optical axis horizontal, vertical, and at 45 deg to attempt to determine any gravity effects on the system. Gravity effects, if present, were masked by scatter in the data associated with the system wavefront error of 0.16 lambda rms ( = 6328A) apparently due to problems in the primary mirror. Tests showed that the redesigned secondary mirror assembly works well.

  1. High Input Voltage, Silicon Carbide Power Processing Unit Performance Demonstration

    Science.gov (United States)

    Bozak, Karin E.; Pinero, Luis R.; Scheidegger, Robert J.; Aulisio, Michael V.; Gonzalez, Marcelo C.; Birchenough, Arthur G.

    2015-01-01

    A silicon carbide brassboard power processing unit has been developed by the NASA Glenn Research Center in Cleveland, Ohio. The power processing unit operates from two sources: a nominal 300 Volt high voltage input bus and a nominal 28 Volt low voltage input bus. The design of the power processing unit includes four low voltage, low power auxiliary supplies, and two parallel 7.5 kilowatt (kW) discharge power supplies that are capable of providing up to 15 kilowatts of total power at 300 to 500 Volts (V) to the thruster. Additionally, the unit contains a housekeeping supply, high voltage input filter, low voltage input filter, and master control board, such that the complete brassboard unit is capable of operating a 12.5 kilowatt Hall effect thruster. The performance of the unit was characterized under both ambient and thermal vacuum test conditions, and the results demonstrate exceptional performance with full power efficiencies exceeding 97%. The unit was also tested with a 12.5kW Hall effect thruster to verify compatibility and output filter specifications. With space-qualified silicon carbide or similar high voltage, high efficiency power devices, this would provide a design solution to address the need for high power electric propulsion systems.

  2. Treatability test plan for the 200-ZP-1 operable unit

    International Nuclear Information System (INIS)

    1994-07-01

    This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-ZP-1 Operable Unit. The approach discussed in this treatability test plan is to conduct a pilot-scale pump and treat test for the contaminant plume associated with the 200-ZP-1 Operable Unit. The primary contaminants of concern are carbon tetrachloride, chloroform, and trichloroethylene (TCE). The pilot-scale treatability testing has as its primary purpose to assess the performance of aboveground treatment systems with respect to the ability to remove the primary contaminants present in groundwater withdrawn from the contaminant plume. The overall scope of this test plan includes: description of the pump and treat system to be tested, as well as the test performance objectives and data quality objectives (DQOs) that will be used to evaluate the effectiveness of the pilot-scale treatment system; discussion of the treatment technology to be tested and supporting development activities, including process flow and conceptual design descriptions and equipment, fabrication, utility, and system startup needs; description of pilot-scale treatment system performance, operating procedures, and operational controls, as well as anticipated monitoring activities, analytes, parameters, analytical procedures, and quality assurance protocols; summaries of other related treatability testing elements, including personnel and environmental health and safety controls, process and secondary waste management and disposition, schedule, and program organization

  3. Severe fuel-damage scoping test performance

    International Nuclear Information System (INIS)

    Gruen, G.E.; Buescher, B.J.

    1983-01-01

    As a result of the Three Mile Island Unit-2 (TMI-2) accident, the Nuclear Regulatory Commission has initiated a severe fuel damage test program to evaluate fuel rod and core response during severe accidents similar to TMI-2. The first test of Phase I of this series has been successfully completed in the Power Burst Facility at the Idaho National Engineering Laboratory. Following the first test, calculations were performed using the TRAC-BD1 computer code with actual experimental boundary conditions. This paper discusses the test conduct and performance and presents the calculated and measured test bundle results. The test resulted in a slow heatup to 2000 K over about 4 h, with an accelerated reaction of the zirconium cladding at temperatures above 1600 K in the lower part or the bundle and 2000 K in the upper portion of the bundle

  4. STATIC TESTS OF UNCONVENTIONAL PROPULSION UNITS FOR ULTRALIGHT AIRPLANES

    Directory of Open Access Journals (Sweden)

    Martin Helmich

    2014-06-01

    Full Text Available This paper presents static tests of a new unconventional propulsion unit for small aviation airplanes. Our laboratory stand – a fan drive demonstrator – enables us to compare various design options. We performed experiments to verify the propulsion functionality and a measurement procedure to determine the available thrust of the propulsion unit and its dependence on engine speed. The results used for subsequent optimization include the operating parameters of the propulsion unit, and the temperature and velocity fields in parts of the air duct.

  5. A study on the optimization of test interval for check valves of Ulchin Unit 3 using the risk-informed in-service testing approach

    International Nuclear Information System (INIS)

    Kang, D. I.; Kim, K. Y.; Yang, Z. A.; Ha, J. J.

    2002-01-01

    We optimized the test interval for check valves of Ulchin Unit 3 using the risk-informed in-service testing (IST) approach. First, we categorized the IST check valves for Ulchin Unit 3 according to their contributions to the safety of Ulchin Unit 3. Next, we performed the risk analysis on the relaxation of test interval for check valves identified as relatively low important to the safety of Ulchin Unit 3 to identify the maximum increasable test interval of them. Finally, we estimated the number of tests of IST check valves to be performed due to the changes of test interval. These study results are as follows: The categorization of IST check valve importance; the number of the HSSCs is 24(11.48%), the ISSCs is 40 (19.14%), and the LSSCs is 462(69.38%). The maximum increasable test interval; 6 times of current test interval of ISSCs2 and 40 times of that of LSSCs. The number of tests of IST check valves to be performed during 6 refueling time can be reduced from 7692 to 1333 ( 82.7%)

  6. The comparison of the unit test tools JUnit and TestNG

    OpenAIRE

    Šarkanj, Aleš

    2011-01-01

    Testing holds an important role in developing software. It is a process ensuring software works as expected. An important part of testing is unit testing as the basic testing level. The purpose of this thesis is comparing JUnit and TestNG, two of the most popular unit testing tools in Java. In the first part we will present testing and its purpose within software development. We will also present the basic terminology and levels of testing. Further on the area of unit testing will be pr...

  7. Initial closed operation of the CELSS Test Facility Engineering Development Unit

    Science.gov (United States)

    Kliss, M.; Blackwell, C.; Zografos, A.; Drews, M.; MacElroy, R.; McKenna, R.; Heyenga, A. G.

    2003-01-01

    As part of the NASA Advanced Life Support Flight Program, a Controlled Ecological Life Support System (CELSS) Test Facility Engineering Development Unit has been constructed and is undergoing initial operational testing at NASA Ames Research Center. The Engineering Development Unit (EDU) is a tightly closed, stringently controlled, ground-based testbed which provides a broad range of environmental conditions under which a variety of CELSS higher plant crops can be grown. Although the EDU was developed primarily to provide near-term engineering data and a realistic determination of the subsystem and system requirements necessary for the fabrication of a comparable flight unit, the EDU has also provided a means to evaluate plant crop productivity and physiology under controlled conditions. This paper describes the initial closed operational testing of the EDU, with emphasis on the hardware performance capabilities. Measured performance data during a 28-day closed operation period are compared with the specified functional requirements, and an example of inferring crop growth parameters from the test data is presented. Plans for future science and technology testing are also discussed. Published by Elsevier Science Ltd on behalf of COSPAR.

  8. Design, fabrication, and dynamic testing of a V-groove radiator mechanical development unit

    Science.gov (United States)

    Petrick, S. Walter; Bard, Steven

    1988-01-01

    This paper describes the design, fabrication, and dynamic testing of a V-groove radiator development unit. The intended goal was to survive the dynamic environment of the Mars Observer mission. The development unit was designed to achieve a temperature of 80 K with a heat load of about 80 milliwatts. An analysis was performed to predict the thermal performance of the development unit. The radiator with a mass mockup of a Gamma Ray Spectrometer detector, the most massive of the candidate Mars Observer instrument detectors (1.7 Kg), passed vibration and acoustic testing to the Mars Observer requirements in effect at that time.

  9. Test report: Electron-proton spectrometer qualification test unit, qualification test

    Science.gov (United States)

    Vincent, D. L.

    1972-01-01

    Qualification tests of the electron-proton spectrometer test unit are presented. The tests conducted were: (1) functional, (2) thermal/vacuum, (3) electromagnetic interference, (4) acoustic, (5) shock, (6) vibration, and (7) humidity. Results of each type of test are presented in the form of data sheets.

  10. High Performance Computing Modernization Program Kerberos Throughput Test Report

    Science.gov (United States)

    2017-10-26

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/5524--17-9751 High Performance Computing Modernization Program Kerberos Throughput Test ...NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2. REPORT TYPE1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 6. AUTHOR(S) 8. PERFORMING...PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT High Performance Computing Modernization Program Kerberos Throughput Test Report Daniel G. Gdula* and

  11. Unit Testing for Command and Control Systems

    Science.gov (United States)

    Alexander, Joshua

    2018-01-01

    Unit tests were created to evaluate the functionality of a Data Generation and Publication tool for a command and control system. These unit tests are developed to constantly evaluate the tool and ensure it functions properly as the command and control system grows in size and scope. Unit tests are a crucial part of testing any software project and are especially instrumental in the development of a command and control system. They save resources, time and costs associated with testing, and catch issues before they become increasingly difficult and costly. The unit tests produced for the Data Generation and Publication tool to be used in a command and control system assure the users and stakeholders of its functionality and offer assurances which are vital in the launching of spacecraft safely.

  12. The increase performance BMF-14 calcination unit

    International Nuclear Information System (INIS)

    Triyono

    2013-01-01

    The heating element of performance increase BMF-14 calcination unit has been installed. The activity includes: installation and function test heating element step by step. The main component includes: kanthal heating element type with size long 58,2 cm diameter 0,9 cm slot total 28, flexible cable resists heat 30 Amperes, band cable heat resists and flexible clamp. The heating elements installation includes from 3 groups and every groups have 4 heating elements to connectly series. Every group connecting to every phase RST and neutral for getting electric voltage 380 Volts follow contact relay 3 phases to controlling by digital temperature control. The resulting installation of heating element in the BMF-14 calcination unit showed that: BMF-14 calcination unit can be again of the setting temperature step by step. In the step I get optimal temperature 560 °C test time 1068 minutes with rate velocity heat 0 to 18,0 °C/minutes with current between 5,8 to 6,4 Amperes voltage 103 to 123 Volts (phase R and T). In the step II gets optimal temperature 600 °C test time 265 minutes getting rate velocity heat 0 to 40,3 °C/minutes with current 3,8 to 8,5 Amperes voltage 76 to 142 Volts (phase RST). In the step III gets optimal temperature 1000 °C test time 107 minutes getting rate velocity heat 0 to 53,5 °C/minutes with current 9,7 to 12,5 Amperes voltage 215 to 225 Volts (phase RST). (author)

  13. Tests of the 30-MJ superconducting magnetic-energy storage unit

    International Nuclear Information System (INIS)

    Boenig, H.J.; Dean, J.W.; Rogers, J.D.; Schermer, R.I.; Hauer, J.F.

    1983-01-01

    A 30-MJ (8.4 kWh) superconducting magnetic energy storage (SMES) unit with a 10-MW converter was installed during the later months of 1982 at the Bonneville Power Administration (BPA) Tacoma substation in Tacoma, Washington. The unit, which is capable of absorbing and releasing up to 10 MJ of energy at a frequency of 0.35 Hz, was designed to damp the dominant power swing mode of the Pacific AC Intertie. Extensive tests were performed with the unit during the first half of 1983. This paper will review the major components of the storage unit and describe the startup and steady state operating experience with the coil, dewar, refrigerator and converter. The unit has absorbed power up to a level of 11.8 Mw. Real power was modulated following a sinusoidal power demand with frequencies from 0.1 to 1.2 Hz and a power level up to +- 8.3 MW. The unit has performed in accordance with design expectations and no major problems have developed

  14. Planter unit test stand

    Science.gov (United States)

    A planter test stand was developed to evaluate individual row-crop metering units in early 2013. This test stand provided the ability to quantify actual seed metering in terms of population, seed spacing, skips, and multiples over a range of meter RPMs and vacuum pressures. Preliminary data has been...

  15. SmartUnit: Empirical Evaluations for Automated Unit Testing of Embedded Software in Industry

    OpenAIRE

    Zhang, Chengyu; Yan, Yichen; Zhou, Hanru; Yao, Yinbo; Wu, Ke; Su, Ting; Miao, Weikai; Pu, Geguang

    2018-01-01

    In this paper, we aim at the automated unit coverage-based testing for embedded software. To achieve the goal, by analyzing the industrial requirements and our previous work on automated unit testing tool CAUT, we rebuild a new tool, SmartUnit, to solve the engineering requirements that take place in our partner companies. SmartUnit is a dynamic symbolic execution implementation, which supports statement, branch, boundary value and MC/DC coverage. SmartUnit has been used to test more than one...

  16. WTP Waste Feed Qualification: Glass Fabrication Unit Operation Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Stone, M. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Hanford Missions Programs; Newell, J. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Process Technology Programs; Johnson, F. C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Engineering Process Development; Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Engineering Process Development

    2016-07-14

    The waste feed qualification program is being developed to protect the Hanford Tank Waste Treatment and Immobilization Plant (WTP) design, safety basis, and technical basis by assuring waste acceptance requirements are met for each staged waste feed campaign prior to transfer from the Tank Operations Contractor to the feed receipt vessels inside the Pretreatment Facility. The Waste Feed Qualification Program Plan describes the three components of waste feed qualification: 1. Demonstrate compliance with the waste acceptance criteria 2. Determine waste processability 3. Test unit operations at laboratory scale. The glass fabrication unit operation is the final step in the process demonstration portion of the waste feed qualification process. This unit operation generally consists of combining each of the waste feed streams (high-level waste (HLW) and low-activity waste (LAW)) with Glass Forming Chemicals (GFCs), fabricating glass coupons, performing chemical composition analysis before and after glass fabrication, measuring hydrogen generation rate either before or after glass former addition, measuring rheological properties before and after glass former addition, and visual observation of the resulting glass coupons. Critical aspects of this unit operation are mixing and sampling of the waste and melter feeds to ensure representative samples are obtained as well as ensuring the fabrication process for the glass coupon is adequate. Testing was performed using a range of simulants (LAW and HLW simulants), and these simulants were mixed with high and low bounding amounts of GFCs to evaluate the mixing, sampling, and glass preparation steps in shielded cells using laboratory techniques. The tests were performed with off-the-shelf equipment at the Savannah River National Laboratory (SRNL) that is similar to equipment used in the SRNL work during qualification of waste feed for the Defense Waste Processing Facility (DWPF) and other waste treatment facilities at the

  17. An intersection test for panel unit roots

    NARCIS (Netherlands)

    Hanck, C.

    2013-01-01

    This article proposes a new panel unit root test based on Simes' ( 1986) classical intersection test. The test is robust to general patterns of cross-sectional dependence and yet is straightforward to implement, only requiring p-values of time series unit root tests of the series in the panel, and

  18. A Nonparametric Test for Seasonal Unit Roots

    OpenAIRE

    Kunst, Robert M.

    2009-01-01

    Abstract: We consider a nonparametric test for the null of seasonal unit roots in quarterly time series that builds on the RUR (records unit root) test by Aparicio, Escribano, and Sipols. We find that the test concept is more promising than a formalization of visual aids such as plots by quarter. In order to cope with the sensitivity of the original RUR test to autocorrelation under its null of a unit root, we suggest an augmentation step by autoregression. We present some evidence on the siz...

  19. Unit testing of AngularJS : A look into writing tests for web application

    OpenAIRE

    Karttunen, Joel

    2016-01-01

    This task was assigned by Protacon Solutions Oy with the objective set to study and implement unit testing in AngularJS JavaScript framework as part of the development process of the customer’s application. The thesis focuses on studying the AngularJS framework and if and how its design philosophy complements the unit testing principles. The focus was on studying unit testing via developing unit tests iteratively onto the application created beforehand. The tests were created with Jas...

  20. Integration testing through reusing representative unit test cases for high-confidence medical software.

    Science.gov (United States)

    Shin, Youngsul; Choi, Yunja; Lee, Woo Jin

    2013-06-01

    As medical software is getting larger-sized, complex, and connected with other devices, finding faults in integrated software modules gets more difficult and time consuming. Existing integration testing typically takes a black-box approach, which treats the target software as a black box and selects test cases without considering internal behavior of each software module. Though it could be cost-effective, this black-box approach cannot thoroughly test interaction behavior among integrated modules and might leave critical faults undetected, which should not happen in safety-critical systems such as medical software. This work anticipates that information on internal behavior is necessary even for integration testing to define thorough test cases for critical software and proposes a new integration testing method by reusing test cases used for unit testing. The goal is to provide a cost-effective method to detect subtle interaction faults at the integration testing phase by reusing the knowledge obtained from unit testing phase. The suggested approach notes that the test cases for the unit testing include knowledge on internal behavior of each unit and extracts test cases for the integration testing from the test cases for the unit testing for a given test criteria. The extracted representative test cases are connected with functions under test using the state domain and a single test sequence to cover the test cases is produced. By means of reusing unit test cases, the tester has effective test cases to examine diverse execution paths and find interaction faults without analyzing complex modules. The produced test sequence can have test coverage as high as the unit testing coverage and its length is close to the length of optimal test sequences. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. 40 CFR Table 11 to Subpart Uuu of... - Requirements for Performance Tests for Organic HAP Emissions From Catalytic Cracking Units Not...

    Science.gov (United States)

    2010-07-01

    ... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU... Organic HAP Emissions From Catalytic Cracking Units Not Subject to New Source Performance Standard (NSPS... From Catalytic Cracking Units Not Subject to New Source Performance Standard (NSPS) for Carbon Monoxide...

  2. Sublimator Driven Coldplate Engineering Development Unit Test Results

    Science.gov (United States)

    Sheth, Rubik B.; Stephan, Ryan A.; Leimkuehler, Thomas O.

    2010-01-01

    The Sublimator Driven Coldplate (SDC) is a unique piece of thermal control hardware that has several advantages over a traditional thermal control scheme. The principal advantage is the possible elimination of a pumped fluid loop, potentially increasing reliability and reducing complexity while saving both mass and power. Because the SDC requires a consumable feedwater, it can only be used for short mission durations. Additionally, the SDC is ideal for a vehicle with small transport distances and low heat rejection requirements. An SDC Engineering Development Unit was designed and fabricated. Performance tests were performed in a vacuum chamber to quantify and assess the performance of the SDC. The test data was then used to develop correlated thermal math models. Nonetheless, an Integrated Sublimator Driven Coldplate (ISDC) concept is being developed. The ISDC couples a coolant loop with the previously described SDC hardware. This combination allows the SDC to be used as a traditional coldplate during long mission phases and provides for dissimilar system redundancy

  3. Reevaluation of Kori Unit 4 Natural Circulation Test

    Energy Technology Data Exchange (ETDEWEB)

    Yassin, Nassir [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Woo, Sweng Woong [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-10-15

    The simulation results showed that the natural circulation flow developed by density difference was capable of removing decay heat from the fuel rod. The maximum pellet centerline temperature of the hot channel showed large margin to the pellet melting temperature. The maximum coolant temperature in the hot channel was well below the saturation temperature. If steam generators provide heat sink to the primary coolant system and thus natural circulation is maintained, the integrity of the fuel in the core can be sustained with large margin. Passive cooling of reactor is inevitable in case of failures in forced cooling system such as loss of electric power for cooling pumps. Fukushima accident showed the importance of the passive core cooling. During the commissioning test of PWRs, natural circulation test is performed to demonstrate the passive core cooling by natural convection. The driving force for coolant flow is developed by the density deference along the loop multiplied by the gravitation. Using the data from 'natural circulation test' and 'RCS flow coast down test' of Kori Unit 4, fuel behavior was reevaluated by FRAPTRAN code. RCS natural circulation test of Kori Unit 4 was reevaluated by FRAPTYRAN simulation to study the fuel behavior during the flow coast down transient and at the equilibrium condition in which decay heat transport and RCS flow were stabilized.

  4. Closure plan for the Test Area North-726 chromate water storage and Test Area North-726A chromate treatment units

    International Nuclear Information System (INIS)

    Smith, P.J.; Van Brunt, K.M.

    1992-11-01

    This document describes the proposed plan for closure of the Test Area North-726 chromate water storage and Test Area North-726A chromate treatment units at the Idaho National Engineering Laboratory in accordance with the Resource Conservation and Recovery Act interim status closure requirements. The location, size, capacity, and history of the units are described, and their current status is discussed. The units will be closed by treating remaining waste in storage, followed by thorough decontamination of the systems. Sufficient sampling and analysis, and documentation of all activities will be performed to demonstrate clean closure

  5. Analysis of solar thermophotovoltaic test data from experiments performed at McDonnell Douglas

    Energy Technology Data Exchange (ETDEWEB)

    Stone, K.W.; Kusek, S.M.; Drubka, R.E. [McDonnell Douglas, 5301 Bolsa Avenue, Huntington Beach, California 92647 (United States); Fay, T.D. [21911 Bacalar, Mission Viejo, California 92692 (United States)

    1995-01-05

    Solar thermophotovoltaic power systems offer potentially high system efficiency for solar energy to electrical energy conversion and attractive system advantages. McDonnell Douglas Corporation (MDC) has been investigating this technology for both space and terrestrial applications for several years. A testbed prototype was designed, built, and tested on a 90 kW{sub t} dish concentrator at the MDA solar test facility. Twelve experiments were conducted with absorber temperatures in excess of 1300 {degree}C being achieved using only a fraction of the reflected power from the 90 kW{sub t} dish concentrator. This paper discusses the solar thermophotovoltaic testbed prototype unit, test data, and presents an analysis of the unit`s performance. A combination of analytical analysis and test data is used to obtain an understanding of the system and subsystem performance. The preliminary results of these tests and analysis indicate a solar thermophotovoltaic power system can achieve high system performance. Furthermore, system demonstrations are possible utilizing a combination of current off-the-shelf hardware components and components currently being tested in laboratories. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  6. Generating units performances: power system requirements

    Energy Technology Data Exchange (ETDEWEB)

    Fourment, C; Girard, N; Lefebvre, H

    1994-08-01

    The part of generating units within the power system is more than providing power and energy. Their performance are not only measured by their energy efficiency and availability. Namely, there is a strong interaction between the generating units and the power system. The units are essential components of the system: for a given load profile the frequency variation follows directly from the behaviour of the units and their ability to adapt their power output. In the same way, the voltage at the units terminals are the key points to which the voltage profile at each node of the network is linked through the active and especially the reactive power flows. Therefore, the customer will experience the frequency and voltage variations induced by the units behaviour. Moreover, in case of adverse conditions, if the units do not operate as well as expected or trip, a portion of the system, may be the whole system, may collapse. The limitation of the performance of a unit has two kinds of consequences. Firstly, it may result in an increased amount of not supplied energy or loss of load probability: for example if the primary reserve is not sufficient, a generator tripping may lead to an abnormal frequency deviation, and load may have to be shed to restore the balance. Secondly, the limitation of a unit performance results in an economic over-cost for the system: for instance, if not enough `cheap` units are able to load-following, other units with higher operating costs have to be started up. We would like to stress the interest for the operators and design teams of the units on the one hand, and the operators and design teams of the system on the other hand, of dialog and information exchange, in operation but also at the conception stage, in order to find a satisfactory compromise between the system requirements and the consequences for the generating units. (authors). 11 refs., 4 figs.

  7. Nearly Efficient Likelihood Ratio Tests for Seasonal Unit Roots

    DEFF Research Database (Denmark)

    Jansson, Michael; Nielsen, Morten Ørregaard

    In an important generalization of zero frequency autore- gressive unit root tests, Hylleberg, Engle, Granger, and Yoo (1990) developed regression-based tests for unit roots at the seasonal frequencies in quarterly time series. We develop likelihood ratio tests for seasonal unit roots and show...... that these tests are "nearly efficient" in the sense of Elliott, Rothenberg, and Stock (1996), i.e. that their local asymptotic power functions are indistinguishable from the Gaussian power envelope. Currently available nearly efficient testing procedures for seasonal unit roots are regression-based and require...... the choice of a GLS detrending parameter, which our likelihood ratio tests do not....

  8. LFK, FORTRAN Application Performance Test

    International Nuclear Information System (INIS)

    McMahon, F.H.

    1991-01-01

    1 - Description of program or function: LFK, the Livermore FORTRAN Kernels, is a computer performance test that measures a realistic floating-point performance range for FORTRAN applications. Informally known as the Livermore Loops test, the LFK test may be used as a computer performance test, as a test of compiler accuracy (via checksums) and efficiency, or as a hardware endurance test. The LFK test, which focuses on FORTRAN as used in computational physics, measures the joint performance of the computer CPU, the compiler, and the computational structures in units of Mega-flops/sec or Mflops. A C language version of subroutine KERNEL is also included which executes 24 samples of C numerical computation. The 24 kernels are a hydrodynamics code fragment, a fragment from an incomplete Cholesky conjugate gradient code, the standard inner product function of linear algebra, a fragment from a banded linear equations routine, a segment of a tridiagonal elimination routine, an example of a general linear recurrence equation, an equation of state fragment, part of an alternating direction implicit integration code, an integrate predictor code, a difference predictor code, a first sum, a first difference, a fragment from a two-dimensional particle-in-cell code, a part of a one-dimensional particle-in-cell code, an example of how casually FORTRAN can be written, a Monte Carlo search loop, an example of an implicit conditional computation, a fragment of a two-dimensional explicit hydrodynamics code, a general linear recurrence equation, part of a discrete ordinates transport program, a simple matrix calculation, a segment of a Planck distribution procedure, a two-dimensional implicit hydrodynamics fragment, and determination of the location of the first minimum in an array. 2 - Method of solution: CPU performance rates depend strongly on the maturity of FORTRAN compiler machine code optimization. The LFK test-bed executes the set of 24 kernels three times, resetting the DO

  9. Understanding protocol performance: impact of test performance.

    Science.gov (United States)

    Turner, Robert G

    2013-01-01

    This is the second of two articles that examine the factors that determine protocol performance. The objective of these articles is to provide a general understanding of protocol performance that can be used to estimate performance, establish limits on performance, decide if a protocol is justified, and ultimately select a protocol. The first article was concerned with protocol criterion and test correlation. It demonstrated the advantages and disadvantages of different criterion when all tests had the same performance. It also examined the impact of increasing test correlation on protocol performance and the characteristics of the different criteria. To examine the impact on protocol performance when individual tests in a protocol have different performance. This is evaluated for different criteria and test correlations. The results of the two articles are combined and summarized. A mathematical model is used to calculate protocol performance for different protocol criteria and test correlations when there are small to large variations in the performance of individual tests in the protocol. The performance of the individual tests that make up a protocol has a significant impact on the performance of the protocol. As expected, the better the performance of the individual tests, the better the performance of the protocol. Many of the characteristics of the different criteria are relatively independent of the variation in the performance of the individual tests. However, increasing test variation degrades some criteria advantages and causes a new disadvantage to appear. This negative impact increases as test variation increases and as more tests are added to the protocol. Best protocol performance is obtained when individual tests are uncorrelated and have the same performance. In general, the greater the variation in the performance of tests in the protocol, the more detrimental this variation is to protocol performance. Since this negative impact is increased as

  10. The digital ultrasonic test unit for automatic equipment

    International Nuclear Information System (INIS)

    Hiraoka, T.; Matsuyama, H.

    1976-01-01

    The operations and features of the ultrasonic test unit used and the digital data processing techniques employed are described. This unit is used for a few hundred multi-channel automatic ultrasonic test equipment

  11. Symbol error rate performance evaluation of the LM37 multimegabit telemetry modulator-demodulator unit

    Science.gov (United States)

    Malek, H.

    1981-01-01

    The LM37 multimegabit telemetry modulator-demodulator unit was tested for evaluation of its symbol error rate (SER) performance. Using an automated test setup, the SER tests were carried out at various symbol rates and signal-to-noise ratios (SNR), ranging from +10 to -10 dB. With the aid of a specially designed error detector and a stabilized signal and noise summation unit, measurement of the SER at low SNR was possible. The results of the tests show that at symbol rates below 20 megasymbols per second (MS)s) and input SNR above -6 dB, the SER performance of the modem is within the specified 0.65 to 1.5 dB of the theoretical error curve. At symbol rates above 20 MS/s, the specification is met at SNR's down to -2 dB. The results of the SER tests are presented with the description of the test setup and the measurement procedure.

  12. Benchmarking in pathology: development of a benchmarking complexity unit and associated key performance indicators.

    Science.gov (United States)

    Neil, Amanda; Pfeffer, Sally; Burnett, Leslie

    2013-01-01

    This paper details the development of a new type of pathology laboratory productivity unit, the benchmarking complexity unit (BCU). The BCU provides a comparative index of laboratory efficiency, regardless of test mix. It also enables estimation of a measure of how much complex pathology a laboratory performs, and the identification of peer organisations for the purposes of comparison and benchmarking. The BCU is based on the theory that wage rates reflect productivity at the margin. A weighting factor for the ratio of medical to technical staff time was dynamically calculated based on actual participant site data. Given this weighting, a complexity value for each test, at each site, was calculated. The median complexity value (number of BCUs) for that test across all participating sites was taken as its complexity value for the Benchmarking in Pathology Program. The BCU allowed implementation of an unbiased comparison unit and test listing that was found to be a robust indicator of the relative complexity for each test. Employing the BCU data, a number of Key Performance Indicators (KPIs) were developed, including three that address comparative organisational complexity, analytical depth and performance efficiency, respectively. Peer groups were also established using the BCU combined with simple organisational and environmental metrics. The BCU has enabled productivity statistics to be compared between organisations. The BCU corrects for differences in test mix and workload complexity of different organisations and also allows for objective stratification into peer groups.

  13. Test Report Emission Test Program EPA Information Collection Request for Delayed Coking Units 736 Coker Unit

    Science.gov (United States)

    ARI Environmental, Inc. (ARI) was retained by Houston Refining LP (HRO) to conduct an emission test program at their refinery located in Houston, Texas. The testing was conducted on on the 736 Delayed Coking Unit (DCU) in response to EPA's ICR.

  14. Performance and burnout in intensive care units

    NARCIS (Netherlands)

    Keijsers, GJ; Schaufeli, WB; LeBlanc, P; Zwerts, C; Miranda, DR

    1995-01-01

    The relationship between three different performance measures and burnout was explored in 20 Dutch Intensive Care Units (ICUs). Burnout (i.e. emotional exhaustion and depersonalization) proved to be significantly related to nurses' perceptions of performance as well as to objectively assessed unit

  15. 29 CFR 1919.30 - Examinations subsequent to unit tests.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Examinations subsequent to unit tests. 1919.30 Section 1919... Treatment; Competent Persons § 1919.30 Examinations subsequent to unit tests. (a) After satisfactory completion of the unit proof load tests required by §§ 1919.27 and 1919.28, the cargo gear and all component...

  16. Some performance characteristics of a fluidized bed heat recovery unit

    International Nuclear Information System (INIS)

    Militzer, J.; Basu, P.; Adaikkappan, N.

    1985-01-01

    The advantages of using fluidized bed heat recovery units with diesel engines are well documented. Two of those are: significantly less tube fouling and heat transfer coefficient four to five time higher than that of conventional shell and tube heat exchangers. The high concentration of soot in the exhaust gases of diesel engines make fouling a major concern in design of any kind of heat recovery unit. In the experiment a conventional fluidized bed heat exchanger was connected to the exhaust of a diesel engine mounted on a dynamometer. With this arrangement it was possible to test the heat recovery unit under a wide range of operating conditions. The main objective of this experiment was the determination of the performance characteristics of the heat recovery unit, especially with reference to its heat transfer and fouling characteristics. (author)

  17. Automation of unit for leakage test

    OpenAIRE

    LYCHKOVSKAYA V.S.; TSYGANKOV A.S.; GRINBERG G.M.; STANOVOVA O.A.

    2015-01-01

    Federal state educational standard requirements for training of university students have been considered. Leakage test procedures for components of aerospace vehicles have been described. Automation procedures of existing laboratory leakage test units have been outlined.

  18. Improving Size and Power in Unit Root Testing

    DEFF Research Database (Denmark)

    Haldrup, Niels; Jansson, Michael

    A frequent criticism of unit root tests concerns the poor power and size properties that many of such testsexhibit. However, the past decade or so intensive research has been conducted to alleviate these problems and great advances have been made. The present paper provides a selective survey...... of recent contributions to improve upon both size and power of unit root tests and in so doing the approach of using rigorous statistical optimality criteria in the development of such tests is stressed. In addition to presenting tests where improved size can be achieved by modifying the standard Dickey......-Fuller class of tests, the paper presents theory of optimal testing and the construction of power envelopes for unit root tests underdifferent conditions allowing for serial correlation, deterministic components, assumptions regarding the initial condition, non-Gaussian errors, and the use of covariates....

  19. Environmental Measurements Laboratory 2002 Unit Performance Plan

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-10-01

    This EML Unit Performance Plan provides the key goals and performance measures for FY 2002 and continuing to FY 2003. The purpose of the Plan is to inform EML's stakeholders and customers of the Laboratory's products and services, and its accomplishments and future challenges. Also incorporated in the Unit Performance Plan is EML's Communication Plan for FY 2002.

  20. Commissioning tests at Bohunice NPP V1 unit 2 after reconstruction in 1998

    International Nuclear Information System (INIS)

    Pajtinka, A.; Tvaroska, V.; Wiening, K.-H.; Mueller, B.

    2000-01-01

    The last and the most extensive stage in the reconstruction project of the Bohunice NPP started in July 1998. The main activities performed during a 6-month scheduled unit 2 outage included: - Installation of a new emergency core cooling system with an increased capacity according to the defined broader break spectrum for LOCA; - Reconstruction of the existing confinement spray system and installation of a new confinement pressure suppression system; - Completion of upgrading measures to increase the reliability of emergency power supply systems (replacement of low voltage switchgear, installation of new cabling for all loads important to safety, installation of new motor-generators and rectifier sets); - Connection to the plant and commissioning of the new reactor protection system. Comprehensive tests and checks performed on completion of installation work on the modified mechanical, electrical and I and C systems were important reasons for the absence of major problems during restart of the unit after the several project implementation phases. Operating experience at unit 2 since its recommissioning in January 1999 has confirmed that the required safety standards have been met and that operational reliability has been substantially increased at the sometime. Periodic testing is being performed in accordance with the limits and conditions for safe operation of Bohunice NPP. To date all these tests were completed without significant problems. The functions implemented in the new technology met the test program criteria, which were approved with authority, in all essential areas. Through the close cooperation of the partners involved and through the combined efforts of the various engineering and operating disciplines, technical and scheduling problems could be immediately identified and quickly resolved. In general, these kinds of projects require optimum cooperation among the parties involved. Modernization of the NPP Bohunice V1 unit 2 has shown, that all

  1. Pilot-scale treatability test plan for the 200-UP-1 groundwater Operable Unit

    International Nuclear Information System (INIS)

    Wittreich, C.D.

    1994-05-01

    This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-UP-1 Operable Unit. This treatability test plan has been prepared in response to an agreement between the US Department of Energy, the US Environmental Protection Agency, and the Washington State Department of Ecology, as documented in Hanford Federal Facility Agreement and Consent Order (Ecology et al. 1989a) Change Control Form M-13-93-03 (Ecology et al. 1994). The agreement also requires that, following completion of the activities described in this test plan, a 200-UP-1 Operable Unit interim remedial measure (IRM) proposed plan be developed for use in preparing an interim action record of decision (ROD). The IRM Proposed Plan will be supported by the results of the testing described in this treatability test plan, as well as by other 200-UP-1 Operable Unit activities (e.g., limited field investigation, development of a qualitative risk assessment). Once issued, the interim action ROD will specify the interim action for groundwater contamination at the 200-UP-1 Operable Unit. The approach discussed in this treatability test plan is to conduct a pilot-scale pump and treat test for the contaminant plume associated with the 200-UP-1 Operable Unit. Primary contaminants of concern are uranium and technetium-99; the secondary contaminant of concern is nitrate. The pilot-scale treatability testing presented in this test plan has as its primary purpose to assess the performance of aboveground treatment systems with respect to the ability to remove the primary contaminants in groundwater withdrawn from the contaminant plume

  2. Design and Implementation of the Control System of an Internal Combustion Engine Test Unit

    Directory of Open Access Journals (Sweden)

    Tufan Koç

    2014-02-01

    Full Text Available Accurate tests and performance analysis of engines are required to minimize measurement errors and so the use of the advanced test equipment is imperative. In other words, the reliable test results depend on the measurement of many parameters and recording the experimental data accurately which is depended on engine test unit. This study aims to design the control system of an internal combustion engine test unit. In the study, the performance parameters of an available internal combustion engine have been transferred to computer in real time. A data acquisition (DAQ card has been used to transfer the experimental data to the computer. Also, a user interface has been developed for performing the necessary procedures by using LabVIEW. The dynamometer load, the fuel consumption, and the desired speed can easily be adjusted precisely by using DAQ card and the user interface during the engine test. Load, fuel consumption, and temperature values (the engine inlet-outlet, exhaust inlet-outlet, oil, and environment can be seen on the interface and also these values can be recorded to the computer. It is expected that developed system will contribute both to the education of students and to the researchers’ studies and so it will eliminate a major lack.

  3. Unit testing as a teaching tool in higher education

    Directory of Open Access Journals (Sweden)

    Peláez Canek

    2016-01-01

    Full Text Available Unit testing in the programming world has had a profound impact in the way modern complex systems are developed. Many Open Source and Free Software projects encourage (and in some cases, mandate the use of unit tests for new code submissions, and many software companies around the world have incorporated unit testing as part of their standard developing practices. And although not all software engineers use them, very few (if at all object their use. However, there is almost no research available pertaining the use of unit tests as a teaching tool in introductory programming courses. I have been teaching introductory programming courses in the Computer Sciences program at the Sciences Faculty in the National Autonomous University of Mexico for almost ten years, and since 2013 I have been using unit testing as a teaching tool in those courses. The intent of this paper is to discuss the results of this experience.

  4. Motivational deficits and cognitive test performance in schizophrenia.

    Science.gov (United States)

    Fervaha, Gagan; Zakzanis, Konstantine K; Foussias, George; Graff-Guerrero, Ariel; Agid, Ofer; Remington, Gary

    2014-09-01

    Motivational and cognitive deficits are core features of schizophrenia, both closely linked with functional outcomes. Although poor effort and decreased motivation are known to affect performance on cognitive tests, the extent of this relationship is unclear in patients with schizophrenia. To evaluate the association between intrinsic motivation and cognitive test performance in patients with schizophrenia. Cross-sectional and 6-month prospective follow-up study performed at 57 sites in the United States, including academic and community medical treatment centers, participating in the Clinical Antipsychotic Trials of Intervention Effectiveness study. The primary sample included 431 stable patients with a DSM-IV diagnosis of schizophrenia currently receiving a stable medication regimen. Cognitive performance and intrinsic motivation were evaluated using a comprehensive neuropsychological test battery and a derived measure from the Heinrichs-Carpenter Quality of Life Scale, respectively. Symptom severity and functional status were also assessed. The primary outcome variable was global neurocognition. Individual domains of cognition were also evaluated for their association with motivation. Level of intrinsic motivation was significantly and positively correlated with global cognitive test performance, a relationship that held for each domain of cognition evaluated (correlation range, 0.20-0.34; P motivation and cognitive performance also remained significant after controlling for antipsychotic dose (P motivation during the 6-month follow-up was also found to be significantly related to improvement in global cognitive performance (P motivation and cognitive performance and suggest that test performance is not purely a measure of ability. Future studies assessing cognition in patients with schizophrenia should consider potential moderating variables such as effort and motivation. Implications for the assessment and interpretation of cognitive impairment based on

  5. Test plan for the field evaluation and demonstration of the Contamination Control Unit

    International Nuclear Information System (INIS)

    Winberg, M.R.; Thompson, D.N.

    1993-06-01

    This report describes test details of a full demonstration of the Contamination Control Unit (CCU). The CCU is a mobile trailer capable of employing the use of soil fixatives, dust suppression agents, misting, and vacuum systems. These systems can perform a large number of contamination control functions to support the Office of Waste Technology Development (OTD) Buried Waste Integrated Demonstration (BWID) projects, transuranic (TRU) waste retrieval operations, and emergency response for hazardous and radioactive materials incidents. The demonstration will include both performance testing at the North Holmes Laboratory Facility (NHLF) and field testing in conjunction with the Remote Excavation System Demonstration at the Cold Test Pit. The NHLF will test operational parameters using water only, and the field demonstration at the Cold Test Pit involves full scale operation of vacuum, fixant, misting, and dust suppression systems. Test objectives, detailed experimental procedures, and data quality objectives necessary to perform the field demonstration are included in this test plan

  6. Pilot-scale treatability test plan for the 200-BP-5 operable unit

    International Nuclear Information System (INIS)

    1994-08-01

    This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-BP-5 Operable Unit. This treatability test plan has been prepared in response to an agreement between the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA), and the State of Washington Department of Ecology (Ecology), as documented in Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement, Ecology et al. 1989a) Change Control Form M-13-93-03 (Ecology et al. 1994) and a recent 200 NPL Agreement Change Control Form (Appendix A). The agreement also requires that, following completion of the activities described in this test plan, a 200-BP-5 Operable Unit Interim Remedial Measure (IRM) Proposed Plan be developed for use in preparing an Interim Action Record of Decision (ROD). The IRM Proposed Plan will be supported by the results of this treatability test plan, as well as by other 200-BP-5 Operable Unit activities (e.g., development of a qualitative risk assessment). Once issued, the Interim Action ROD will specify the interim action(s) for groundwater contamination at the 200-BP-5 Operable Unit. The treatability test approach is to conduct a pilot-scale pump and treat test for each of the two contaminant plumes associated with the 200-BP-5 Operable Unit. Primary contaminants of concern are 99 Tc and 60 Co for underwater affected by past discharges to the 216-BY Cribs, and 90 Sr, 239/240 Pu, and Cs for groundwater affected by past discharges to the 216-B-5 Reverse Well. The purpose of the pilot-scale treatability testing presented in this testplan is to provide the data basis for preparing an IRM Proposed Plan. To achieve this objective, treatability testing must: Assess the performance of groundwater pumping with respect to the ability to extract a significant amount of the primary contaminant mass present in the two contaminant plumes

  7. Radioactive material packaging performance testing

    International Nuclear Information System (INIS)

    Romano, T.

    1992-06-01

    In an effort to provide uniform packaging of hazardous material on an international level, recommendations for the transport of dangerous goods have been developed by the United Nations. These recommendations are performance oriented and contrast with a large number of packaging specifications in the US Department of Transportation's hazard materials regulations. This dual system presents problems when international shipments enter the US Department of Transportation's system. Faced with the question of continuing a dual system or aligning with the international system, the Research and Special Programs Administration of the US Department of Transportation responded with Docket HM-181. This began the transition toward the international transportation system. Following close behind is Docket HM-169A, which addressed low specific activity radioactive material packaging. This paper will discuss the differences between performance-oriented and specification packaging, the transition toward performance-oriented packaging by the US Department of Transportation, and performance-oriented testing of radioactive material packaging by Westinghouse Hanford Company. Dockets HM-181 and HM-169A will be discussed along with Type A (low activity) and Type B (high activity) radioactive material packaging evaluations

  8. Assessment of the Performance of a Ventilated Window Coupled with a Heat Recovery Unit through the Co-Heating Test

    Directory of Open Access Journals (Sweden)

    Ludovico Danza

    2016-01-01

    Full Text Available The aim of the article is to describe the results of an experimental campaign based on the assessment of a heat recovery unit coupled with a dynamic window. Two fully monitored and calibrated outdoor test cells are used, in order to evaluate the energy performance and the related thermal comfort. The former presents a traditional window with double-glazing, aluminum frame and indoor blind and a centrifugal extractor for the air circulation. The latter is equipped with a dynamic window with ventilated and blinded double-glazing provided with a heat exchanger. The connection of the dynamic window and heat recovery unit provides different actions: heat recovery; heat transfer reduction; pre-heating before the exchanger. Different operating configurations allowed the trends of the dynamic system to be assessed in different seasons in terms of energy saving, thermal comfort behavior and energy efficiency. The results showed an overall lower consumption of the innovative system, both in winter and summer, with 20% and 15% energy saving, respectively. In general, the dynamic system provided the best comfort conditions, even if it involves a worse behavior than expected, in the summer season.

  9. Earth Observing System (EOS)/ Advanced Microwave Sounding Unit-A (AMSU-A): Special Test Equipment. Software Requirements

    Science.gov (United States)

    Schwantje, Robert

    1995-01-01

    This document defines the functional, performance, and interface requirements for the Earth Observing System/Advanced Microwave Sounding Unit-A (EOS/AMSU-A) Special Test Equipment (STE) software used in the test and integration of the instruments.

  10. Corrective Action Decision Document/Closure Report for Corrective Action Unit 370: T-4 Atmospheric Test Site, Nevada Test Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Patrick Matthews

    2009-05-01

    This Corrective Action Decision Document/Closure Report has been prepared for Corrective Action Unit (CAU) 370, T-4 Atmospheric Test Site, located in Area 4 at the Nevada Test Site, Nevada, in accordance with the Federal Facility Agreement and Consent Order (FFACO). Corrective Action Unit 370 is comprised of Corrective Action Site (CAS) 04-23-01, Atmospheric Test Site T-4. The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation that no further corrective action is needed for CAU 370 due to the implementation of the corrective action of closure in place with administrative controls. To achieve this, corrective action investigation (CAI) activities were performed from June 25, 2008, through April 2, 2009, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 370: T-4 Atmospheric Test Site and Record of Technical Change No. 1.

  11. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  12. Automatic TV X-ray unit for testing aluminium castings

    International Nuclear Information System (INIS)

    Morgunov, V.I.; Firstov, V.G.; Kisin, V.I.; Savostenok, M.I.

    1989-01-01

    The automatic TV X-ray unit for testing of aluminum alloy castings in a flow is described. The unit includes RAP-150/300 X-ray apparatus and PI-60TK TV X-ray device. The biological protection chamber and the common control board are the main functional units. The tests of the unit have shown that as regards its characteristics it is not worse than its foreign-made analogues, for example, devices of the DP-35 and DP-38 type of the 'Seifert' company

  13. A New Nonlinear Unit Root Test with Fourier Function

    OpenAIRE

    Güriş, Burak

    2017-01-01

    Traditional unit root tests display a tendency to be nonstationary in the case of structural breaks and nonlinearity. To eliminate this problem this paper proposes a new flexible Fourier form nonlinear unit root test. This test eliminates this problem to add structural breaks and nonlinearity together to the test procedure. In this test procedure, structural breaks are modeled by means of a Fourier function and nonlinear adjustment is modeled by means of an Exponential Smooth Threshold Autore...

  14. Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit

    Science.gov (United States)

    Lewandowski, Edward J.; Schreiber, Jeffrey G.; Oriti, Salvatore M.; Meer, David W.; Brace, Michael H.; Dugala, Gina

    2009-01-01

    The Advanced Stirling Radioisotope Generator (ASRG) is being considered to power deep space missions. An engineering unit, the ASRG-EU, was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently on an extended operation test at NASA Glenn Research Center to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for testing the ASRG-EU. Details of the test facility design are discussed. The facility can operate the convertors under AC bus control or with the ASRG-EU controller. It can regulate input thermal power in either a fixed temperature or fixed power mode. An enclosure circulates cooled air around the ASRG-EU to remove heat rejected from the ASRG-EU by convection. A custom monitoring and data acquisition system supports the test. Various safety features, which allow 2417 unattended operation, are discussed.

  15. Human resource management and unit performance in knowledge-intensive work.

    Science.gov (United States)

    Kehoe, Rebecca R; Collins, Christopher J

    2017-08-01

    To clarify the potential value of a targeted system of human resource (HR) practices, we explore the unique effects of a relationship-oriented HR system and the more commonly studied high commitment HR system on unit performance in the context of knowledge-intensive work. We develop theoretical arguments suggesting that the high commitment HR system contributes to unit performance through its positive effects on employees' collective organizational commitment, general and firm-specific human capital, and access to knowledge. We argue that the relationship-oriented HR system contributes to unit performance through its positive effects on employees' collective access to knowledge by fostering a social context and interpersonal exchange conditions which support employees' ongoing access to knowledge flows within and outside their unit and broader organization. Based on unit-level data collected from a matched sample of employees and managers in 128 units in the science and engineering division of a large hydroelectric power organization, our results suggest that the targeted, relationship-oriented HR system is related to firm performance and may complement a broader, high commitment approach to managing knowledge workers. Specifically, the positive relationship between the high commitment HR system and unit performance is mediated by employees' collective organizational commitment, firm-specific human capital, and access to knowledge in other organizational units; whereas the positive relationship between the relationship-oriented HR system and unit performance is mediated by units' access to knowledge within the unit, in other units, and outside the organization. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  16. Streamlined Approach for Environmental Restoration Work Plan for Corrective Action Unit 461: Joint Test Assembly Sites and Corrective Action Unit 495: Unconfirmed Joint Test Assembly Sites Tonopah Test Range, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Jeff Smith

    1998-08-01

    This Streamlined Approach for Environmental Restoration plan addresses the action necessary for the clean closure of Corrective Action Unit 461 (Test Area Joint Test Assembly Sites) and Corrective Action Unit 495 (Unconfirmed Joint Test Assembly Sites). The Corrective Action Units are located at the Tonopah Test Range in south central Nevada. Closure for these sites will be completed by excavating and evaluating the condition of each artillery round (if found); detonating the rounds (if necessary); excavating the impacted soil and debris; collecting verification samples; backfilling the excavations; disposing of the impacted soil and debris at an approved low-level waste repository at the Nevada Test Site

  17. Unit Testing for the Application Control Language (ACL) Software

    Science.gov (United States)

    Heinich, Christina Marie

    2014-01-01

    In the software development process, code needs to be tested before it can be packaged for release in order to make sure the program actually does what it says is supposed to happen as well as to check how the program deals with errors and edge cases (such as negative or very large numbers). One of the major parts of the testing process is unit testing, where you test specific units of the code to make sure each individual part of the code works. This project is about unit testing many different components of the ACL software and fixing any errors encountered. To do this, mocks of other objects need to be created and every line of code needs to be exercised to make sure every case is accounted for. Mocks are important to make because it gives direct control of the environment the unit lives in instead of attempting to work with the entire program. This makes it easier to achieve the second goal of exercising every line of code.

  18. Performance demonstration experience for reactor pressure vessel shell ultrasonic testing

    International Nuclear Information System (INIS)

    Zado, V.

    1998-01-01

    The most ultrasonic testing techniques used by many vendors for pressurized water reactor (PWR) examinations were based on American Society of Mechanical Engineers 'Boiler and Pressurized Vessel Code' (ASME B and PV Code) Sections XI and V. The Addenda of ASME B and PV Code Section XI, Edition 1989 introduced Appendix VIII - 'Performance Demonstration for Ultrasonic Examination Systems'. In an effort to increase confidence in performance of ultrasonic testing of the operating nuclear power plants in United States, the ultrasonic testing performance demonstration examination of reactor vessel welds is performed in accordance with Performance Demonstration Initiative (PDI) program which is based on ASME Code Section XI, Appendix VIII requirements. This article provides information regarding extensive qualification preparation works performed prior EPRI guided performance demonstration exam of reactor vessel shell welds accomplished in January 1997 for the scope of Appendix VIII, Supplements IV and VI. Additionally, an overview of the procedures based on requirements of ASME Code Section XI and V in comparison to procedure prepared for Appendix VIII examination is given and discussed. The samples of ultrasonic signals obtained from artificial flaws implanted in vessel material are presented and results of ultrasonic testing are compared to actual flaw sizes. (author)

  19. Proton Testing of Advanced Stellar Compass Digital Processing Unit

    DEFF Research Database (Denmark)

    Thuesen, Gøsta; Denver, Troelz; Jørgensen, Finn E

    1999-01-01

    The Advanced Stellar Compass Digital Processing Unit was radiation tested with 300 MeV protons at Proton Irradiation Facility (PIF), Paul Scherrer Institute, Switzerland.......The Advanced Stellar Compass Digital Processing Unit was radiation tested with 300 MeV protons at Proton Irradiation Facility (PIF), Paul Scherrer Institute, Switzerland....

  20. Near Earth Asteroid Scout Solar Sail Engineering Development Unit Test Suite

    Science.gov (United States)

    Lockett, Tiffany Russell; Few, Alexander; Wilson, Richard

    2017-01-01

    The Near Earth Asteroid (NEA) Scout project is a 6U reconnaissance mission to investigate a near Earth asteroid utilizing an 86m(sub 2) solar sail as the primary propulsion system. This will be the largest solar sail NASA has launched to date. NEA Scout is currently manifested on the maiden voyage of the Space Launch System in 2018. In development of the solar sail subsystem, design challenges were identified and investigated for packaging within a 6U form factor and deployment in cis-lunar space. Analysis was able to capture understanding of thermal, stress, and dynamics of the stowed system as well as mature an integrated sail membrane model for deployed flight dynamics. Full scale system testing on the ground is the optimal way to demonstrate system robustness, repeatability, and overall performance on a compressed flight schedule. To physically test the system, the team developed a flight sized engineering development unit with design features as close to flight as possible. The test suite included ascent vent, random vibration, functional deployments, thermal vacuum, and full sail deployments. All of these tests contributed towards development of the final flight unit. This paper will address several of the design challenges and lessons learned from the NEA Scout solar sail subsystem engineering development unit. Testing on the component level all the way to the integrated subsystem level. From optical properties of the sail material to fold and spooling the single sail, the team has developed a robust deployment system for the solar sail. The team completed several deployments of the sail system in preparation for flight at half scale (4m) and full scale (6.8m): boom only, half scale sail deployment, and full scale sail deployment. This paper will also address expected and received test results from ascent vent, random vibration, and deployment tests.

  1. 29 CFR 1919.73 - Unit proof test and examination of derricks.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof test and examination of derricks. 1919.73 Section 1919.73 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Devices § 1919.73 Unit proof test and examination of derricks. (a) Unit proof tests of derricks shall be...

  2. Textiles Performance Testing Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Textiles Performance Testing Facilities has the capabilities to perform all physical wet and dry performance testing, and visual and instrumental color analysis...

  3. Zeroing and testing units developed for Gerdien atmospheric ion detectors

    International Nuclear Information System (INIS)

    Kolarz, P.; Marinkovic, B.P.; Filipovic, D.M.

    2005-01-01

    Low current measurements in atmospheric ion detection using a Gerdien condenser are subjected to numerous sources of error. Zeroing and testing units described in this article, connected as modules to this type of detector, enable some of these errors to be found and eliminated. The zeroing unit provides digital compensation of the zero drift with a digital sample and hold circuit of 12-bit resolution. It overcomes difficulties related to zero drift and techniques used in the zero conductivity determination when the accelerating potential or airflow rate are zero. The testing unit is a current reference of nominally 10 -12 A intended for testing and correcting the system on current leakage and other measuring deviations due to changes in atmospheric parameters. This unit is an independent battery-powered module, which provides a charge of 10 -12 C per cycle (frequency of order 1 Hz) to the collecting electrode. The control of Gerdien devices is substantially simplified using the zeroing and testing units realized here. Both units are used during 'zero conductivity' regime only

  4. Research on Design and Simulation of Biaxial Tensile-Bending Complex Mechanical Performance Test Apparatus

    Directory of Open Access Journals (Sweden)

    Hailian Li

    2017-09-01

    Full Text Available In order to realize a micro-mechanic performance test of biaxial tensile-bending-combined loading and solve the problem of incompatibility of test apparatus and observation apparatus, novel biaxial-combined tensile-bending micro-mechanical performance test apparatus was designed. The working principle and major functions of key constituent parts of test apparatus, including the servo drive unit, clamping unit and test system, were introduced. Based on the finite element method, biaxial tensile and tension-bending-combined mechanical performances of the test-piece were studied as guidance to learn the distribution of elastic deformation and plastic deformation of all sites of the test-piece and to better plan test regions. Finally, this test apparatus was used to conduct a biaxial tensile test under different pre-bending loading and a tensile test at different rates; the image of the fracture of the test-piece was acquired by a scanning electron microscope and analyzed. It was indicated that as the pre-bending force rises, the elastic deformation phase would gradually shorten and the slope of the elastic deformation phase curve would slightly rise so that a yield limit would appear ahead of time. Bending speed could exert a positive and beneficial influence on tensile strength but weaken fracture elongation. If bending speed is appropriately raised, more ideal anti-tensile strength could be obtained, but fracture elongation would decline.

  5. Testing of the Advanced Stirling Radioisotope Generator Engineering Unit at NASA Glenn Research Center

    Science.gov (United States)

    Lewandowski, Edward J.

    2013-01-01

    The Advanced Stirling Radioisotope Generator (ASRG) is a high-efficiency generator being developed for potential use on a Discovery 12 space mission. Lockheed Martin designed and fabricated the ASRG Engineering Unit (EU) under contract to the Department of Energy. This unit was delivered to NASA Glenn Research Center in 2008 and has been undergoing extended operation testing to generate long-term performance data for an integrated system. It has also been used for tests to characterize generator operation while varying control parameters and system inputs, both when controlled with an alternating current (AC) bus and with a digital controller. The ASRG EU currently has over 27,000 hours of operation. This paper summarizes all of the tests that have been conducted on the ASRG EU over the past 3 years and provides an overview of the test results and what was learned.

  6. Operator performance in non-destructive testing: A study of operator performance in a performance test

    Energy Technology Data Exchange (ETDEWEB)

    Enkvist, J.; Edland, A.; Svenson, Ola [Stockholm Univ. (Sweden). Dept. of Psychology

    2000-05-15

    In the process industries there is a need of inspecting the integrity of critical components without disrupting the process. Such in-service inspections are typically performed with non-destructive testing (NDT). In NDT the task of the operator is to (based on diagnostic information) decide if the component can remain in service or not. The present study looks at the performance in NDT. The aim is to improve performance, in the long run, by exploring the operators' decision strategies and other underlying factors and to this way find out what makes some operators more successful than others. Sixteen operators performed manual ultrasonic inspections of four test pieces with the aim to detect (implanted) cracks. In addition to these performance demonstration tests (PDT), the operators performed independent ability tests and filled out questionnaires. The results show that operators who trust their gut feeling more than the procedure (when the two come to different results) and that at the same time have a positive attitude towards the procedure have a higher PDT performance. These results indicate the need for operators to be motivated and confident when performing NDT. It was also found that the operators who performed better rated more decision criteria higher in the detection phase than the operators who performed worse. For characterizing it was the other way around. Also, the operators who performed better used more time, both detecting and characterizing, than the operators who performed worse.

  7. Operator performance in non-destructive testing: A study of operator performance in a performance test

    International Nuclear Information System (INIS)

    Enkvist, J.; Edland, A.; Svenson, Ola

    2000-05-01

    In the process industries there is a need of inspecting the integrity of critical components without disrupting the process. Such in-service inspections are typically performed with non-destructive testing (NDT). In NDT the task of the operator is to (based on diagnostic information) decide if the component can remain in service or not. The present study looks at the performance in NDT. The aim is to improve performance, in the long run, by exploring the operators' decision strategies and other underlying factors and to this way find out what makes some operators more successful than others. Sixteen operators performed manual ultrasonic inspections of four test pieces with the aim to detect (implanted) cracks. In addition to these performance demonstration tests (PDT), the operators performed independent ability tests and filled out questionnaires. The results show that operators who trust their gut feeling more than the procedure (when the two come to different results) and that at the same time have a positive attitude towards the procedure have a higher PDT performance. These results indicate the need for operators to be motivated and confident when performing NDT. It was also found that the operators who performed better rated more decision criteria higher in the detection phase than the operators who performed worse. For characterizing it was the other way around. Also, the operators who performed better used more time, both detecting and characterizing, than the operators who performed worse

  8. Development of field simulator to test and qualify the gyrotron local control unit for ITER-India Gyrotron Test Facility

    International Nuclear Information System (INIS)

    Shah, Ronak; Mandge, Deepak; Rathod, Vipal; Parmar, Rajvi; Dilip, E. Sharan; Yadav, Amit; Sharma, Anjali; Rao, S.L.

    2017-01-01

    High power RF sources such as a Gyrotron system are operated at required output parameter by using various auxiliary power supplies, High voltage power supplies, auxiliary services and a dedicated Local Control Unit (LCU). These sub-systems must be operated in synchronous and safe way to control the gyrotron output parameters. The LCU performs remote, synchronous and safe operation of the all the gyrotron sub-systems. Broadly the LCU functions are operational control, data acquisition, protection and safety of the gyrotron system. At ITER-India gyrotron Test Facility (IIGTF) a local control unit (LCU) is being developed to operate the complete gyrotron system. This paper presents the design, development and various features of the field simulator. It also discuss LCU functionality test cases and results obtained using field simulator

  9. The 4th surveillance testing for Kori unit 3 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwun Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-10-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Kori unit 3 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 4.983E+18, 1.641E+19, 3.158E+19, and 4.469E+19n/cm{sup 2}, respectively. The bias factor, the ratio of calculation/measurement, was 0.840 for the 1st through 4th testing and the calculational uncertainty, 12% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.362E+19n/cm{sup 2} based on the end of 12th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.481E+19, 4.209E+19, 5.144E+19 and 5.974E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Kori unit 3 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 48 refs., 35 figs., 41 tabs. (Author)

  10. 29 CFR 1919.71 - Unit proof test and examination of cranes.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof test and examination of cranes. 1919.71 Section... § 1919.71 Unit proof test and examination of cranes. (a) Unit proof tests of cranes shall be carried out at the following times: (1) In the cases of new cranes, before initial use and every 4 years...

  11. A unit root test based on smooth transitions and nonlinear adjustment

    OpenAIRE

    Hepsag, Aycan

    2017-01-01

    In this paper, we develop a new unit root testing procedure which considers jointly for structural breaks and nonlinear adjustment. The structural breaks are modelled by means of a logistic smooth transition function and nonlinear adjustment is modelled by means of an ESTAR model. The empirical size of test is quite close to the nominal one and in terms of power; the new unit root test is generally superior to the alternative test. The new unit root test presents good size properties and does...

  12. Final test results for the ground operations demonstration unit for liquid hydrogen

    Science.gov (United States)

    Notardonato, W. U.; Swanger, A. M.; Fesmire, J. E.; Jumper, K. M.; Johnson, W. L.; Tomsik, T. M.

    2017-12-01

    Described herein is a comprehensive project-a large-scale test of an integrated refrigeration and storage system called the Ground Operations and Demonstration Unit for Liquid Hydrogen (GODU LH2), sponsored by the Advanced Exploration Systems Program and constructed at Kennedy Space Center. A commercial cryogenic refrigerator interfaced with a 125,000 l liquid hydrogen tank and auxiliary systems in a manner that enabled control of the propellant state by extracting heat via a closed loop Brayton cycle refrigerator coupled to a novel internal heat exchanger. Three primary objectives were demonstrating zero-loss storage and transfer, gaseous liquefaction, and propellant densification. Testing was performed at three different liquid hydrogen fill-levels. Data were collected on tank pressure, internal tank temperature profiles, mass flow in and out of the system, and refrigeration system performance. All test objectives were successfully achieved during approximately two years of testing. A summary of the final results is presented in this paper.

  13. 30 CFR 74.5 - Tests of coal mine dust personal sampler units.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of coal mine dust personal sampler units... Personal Sampler Unit § 74.5 Tests of coal mine dust personal sampler units. (a) The National Institute for... tests and evaluations to determine whether the pump unit of a CMDPSU that is submitted for approval...

  14. An Investigation into the Cost of Unit Testing on an Embedded System

    OpenAIRE

    Qiu, Wensi

    2011-01-01

    The quality of embedded software is important, especially for life-critical and mission-critical embedded systems. And software testing is a key activity to ensure the quality of embedded software. Both system testing and unit testing are vital to test embedded software. Unit testing is probably more important to ensure there are no latent faults. System testing is almost invariably done on a target system, but unit testing is normally done on a host system, as standard test frame...

  15. Testing the efficiency of the wine market using unit root tests with sharp and smooth breaks

    Directory of Open Access Journals (Sweden)

    Elie Bouri

    2017-12-01

    Full Text Available This paper examines the efficient market hypothesis for the wine market using a novel unit root test while accounting for sharp shifts and smooth breaks in the monthly data. We find evidence of structural shifts and nonlinearity in the wine indices. Contrary to the results from conventional linear unit root tests, when we account for sharp shifts and smooth breaks, the unit root null for each of the wine indices has been rejected. Overall, our results suggest that the wine market is inefficient when we incorporate breaks. We provide some practical and policy implications of our findings. Keywords: Wine market, Efficiency, Sharp and smooth breaks, Unit root tests

  16. Plant Outage Time Savings Provided by Subcritical Physics Testing at Vogtle Unit 2

    International Nuclear Information System (INIS)

    Cupp, Philip; Heibel, M.D.

    2006-01-01

    The most recent core reload design verification physics testing done at Southern Nuclear Company's (SNC) Vogtle Unit 2, performed prior to initial power operations in operating cycle 12, was successfully completed while the reactor was at least 1% ΔK/K subcritical. The testing program used was the first application of the Subcritical Physics Testing (SPT) program developed by the Westinghouse Electric Company LLC. The SPT program centers on the application of the Westinghouse Subcritical Rod Worth Measurement (SRWM) methodology that was developed in cooperation with the Vogtle Reactor Engineering staff. The SRWM methodology received U. S. Nuclear Regulatory Commission (NRC) approval in August of 2005. The first application of the SPT program occurred at Vogtle Unit 2 in October of 2005. The results of the core design verification measurements obtained during the SPT program demonstrated excellent agreement with prediction, demonstrating that the predicted core characteristics were in excellent agreement with the actual operating characteristics of the core. This paper presents an overview of the SPT Program used at Vogtle Unit 2 during operating cycle 12, and a discussion of the critical path outage time savings the SPT program is capable of providing. (authors)

  17. A Cryogenic Test Station for the Pre-series 2400 W @ 1.8 K Refrigeration Units for the LHC

    CERN Document Server

    Claudet, S; Gully, P; Jäger, B; Millet, F; Roussel, P; Tavian, L

    2002-01-01

    The cooling capacity below 2 K for the superconducting magnets in the Large Hadron Collider (LHC), at CERN, will be provided by eight refrigeration units at 1.8 K, each of them coupled to a 4.5 K refrigerator. The supply of the series units is linked to successful testing and acceptance of the pre-series delivered by the two selected vendors. To properly assess the performance of specific components such as cold compressors and some process specificities a dedicated test station is necessary. The test station is able to process up to 130 g/s between 4.5 & 20 K and aims at simulating the steady and transient operational modes foreseen for the LHC. After recalling the basic characteristics of the 1.8 K refrigeration units and the content of the acceptance tests of the pre-series, the principle of the test cryostat is detailed. The components of the test station and corresponding layout are described. The first testing experience is presented as well as preliminary results of the pre-series units.

  18. Anechoic Chamber test of the Electromagnetic Measurement System ground test unit

    Science.gov (United States)

    Stevenson, L. E.; Scott, L. D.; Oakes, E. T.

    1987-04-01

    The Electromagnetic Measurement System (EMMS) will acquire data on electromagnetic (EM) environments at key weapon locations on various aircraft certified for nuclear weapons. The high-frequency ground unit of the EMMS consists of an instrumented B61 bomb case that will measure (with current probes) the localized current density resulting from an applied EM field. For this portion of the EMMS, the first system test was performed in the Anechoic Chamber Facility at Sandia National Laboratories, Albuquerque, New Mexico. The EMMS pod was subjected to EM radiation at microwave frequencies of 1, 3, and 10 GHz. At each frequency, the EMMS pod was rotated at many positions relative to the microwave source so that the individual current probes were exposed to a direct line-of-sight illumination. The variations between the measured and calculated electric fields for the current probes with direct illumination by the EM source are within a few db. The results obtained from the anechoic test were better than expected and verify that the high frequency ground portion of the EMMS will accurately measure the EM environments for which it was designed.

  19. Some pitfalls in unit root testing

    NARCIS (Netherlands)

    Bakker, B.B.; Koning, Ruud H.

    1991-01-01

    Testing for unit roots is now common practice for economists. The most popular procedure is the approach developed by Dickey and Fuller (1979, 1981), which only requires running appropriately specified regressions. However, application of the Dickey-Fuller procedure requires that the disturbance

  20. Test procedures, AN/AIC-27 system and component units. [for space shuttle

    Science.gov (United States)

    Reiff, F. H.

    1975-01-01

    The AN/AIC-27 (v) intercommunication system is a 30-channel audio distribution which consists of: air crew station units, maintenance station units, and a central control unit. A test procedure for each of the above units and also a test procedure for the system are presented. The intent of the test is to provide data for use in shuttle audio subsystem design.

  1. A Performance Evaluation of a Notebook PC under a High Dose-Rate Gamma Ray Irradiation Test

    Directory of Open Access Journals (Sweden)

    Jai Wan Cho

    2014-01-01

    Full Text Available We describe the performance of a notebook PC under a high dose-rate gamma ray irradiation test. A notebook PC, which is small and light weight, is generally used as the control unit of a robot system and loaded onto the robot body. Using TEPCO’s CAMS (containment atmospheric monitoring system data, the gamma ray dose rate before and after a hydrogen explosion in reactor units 1–3 of the Fukushima nuclear power plant was more than 150 Gy/h. To use a notebook PC as the control unit of a robot system entering a reactor building to mitigate the severe accident situation of a nuclear power plant, the performance of the notebook PC under such intense gamma-irradiation fields should be evaluated. Under a similar dose-rate (150 Gy/h gamma ray environment, the performances of different notebook PCs were evaluated. In addition, a simple method for a performance evaluation of a notebook PC under a high dose-rate gamma ray irradiation test is proposed. Three notebook PCs were tested to verify the method proposed in this paper.

  2. Development and field tests of a damping controller to mitigate electromechanical oscillations on large diesel generating units

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Fabricio G.; Barreiros, Jose A.L.; Barra, Walter Jr.; Costa, Carlos T. Jr. [Universidade Federal do Para (UFPA), Instituto de Tecnologia, Faculdade de Engenharia Eletrica, Campus Universitario do Guama, CEP: 66075-900, Belem (Brazil); Ferreira, Andre M.D. [Instituto Federal de Educacao, Ciencia e Tecnologia do Para (IFPA), Campus Belem, Departamento de Controle e Processos Industriais, Av. Almirante Barroso, 1155 (Marco), CEP: 66093-020, Belem (Brazil)

    2011-02-15

    This paper presents the development and field tests of a digital damping controller designed to mitigate intra-plant electromechanical oscillations via the speed governor system of fast acting units. The controller performance is assessed on an 18-MVA diesel generating unit, at Santana Power Plant (Amapa State, Amazon Region at Northern Brazil). In order to design the damping control law, a set of parametric ARX models representing the plant dynamics at several load conditions, are previously identified from data collected on field tests. The damping controller gains are calculated by using the identified ARX models parameters as inputs to a discrete-time pole-placement design method (pole-shifting) and then embedded on a DSP based microcontroller digital system, for field tests assessment. The digital damping controller modulates the diesel engine inlet valve position according to the observed oscillation on the measured electric power, using a PWM device, which is specially developed to this application. The experimental results shown the good performance of the developed controller on damping efficiently the electromechanical oscillations observed between generating units at Santana Power Plant. (author)

  3. Field Tests of Wind Turbine Unit with Tandem Wind Rotors and Double Rotational Armatures

    Science.gov (United States)

    Galal, Ahmed Mohamed; Kanemoto, Toshiaki

    This paper discusses the field tests of the wind turbine unit, in which the front and the rear wind rotors drive the inner and the outer armatures of the synchronous generator. The wind rotors were designed conveniently by the traditional procedure for the single wind rotor, where the diameters of the front and the rear wind rotors are 2 m and 1.33 m. The tests were done on a pick-up type truck driven straightly at constant speed. The rotational torque of the unit is directly proportional to the induced electric current irrespective of the rotational speeds of the wind rotors, while the induced voltage is proportional to the relative rotational speed. The performance of the unit is significantly affected not only by the wind velocity, but also by the blade setting angles of both wind rotors and the applied load especially at lower wind velocity.

  4. Full scale dynamic testing of Kozloduy NPP unit 5 structures

    International Nuclear Information System (INIS)

    Da Rin, E.M.

    1999-01-01

    As described in this report, the Kozloduy NPP western site has been subjected to low level earthquake-like ground shaking - through appropriately devised underground explosions - and the resulting dynamic response of the NPP reactor Unit 5 important structures appropriately measured and digitally recorded. In-situ free-field response was measured concurrently more than 100 m aside the main structures of interest. The collected experimental data provide reference information on the actual dynamic characteristics of the Kozloduy NPPs main structures, as well as give some useful indications on the dynamic soil-structure interaction effects for the case of low level excitation. Performing the present full-scale dynamic structural testing activities took advantage of the experience gained by ISMES during similar tests, lately performed in Italy and abroad (in particular, at the Paks NPP in 1994). The IAEA promoted dynamic testing of the Kozloduy NPP Unit 5 by means of pertinently designed buried explosion-induced ground motions which has provided a large amount of data on the dynamic structural response of its major structures. In the present report, the conducted investigation is described and the acquired digital data presented. A series of preliminary analyses were undertaken for examining in detail the ground excitation levels that were produced by these weak earthquake simulation experiments, as well as for inferring some structural characteristics and behaviour information from the collected data. These analyses ascertained the high quality of the collected digital data. Presumably due to soil-structure dynamic interaction effects, reduced excitation levels were observed at the reactor building foundation raft level with respect to the concurrent free-field ground motions. measured at a 140 m distance from the reactor building centre. Further more detailed and systematic analyses are worthwhile to be performed for extracting more complete information about the

  5. The 5th surveillance testing for Kori unit 2 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-03-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Kori unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules V, R, P, T and N are 2.837E+18, 1.105E+19, 2.110E+19, 3.705E+19 and 4.831E+19n/cm{sup 2}, respectively. The bias factor, the ratio of measurement/calculation, was 0.918 for the 1st through 5th testing and the calculational uncertainty, 11.6% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.898E+19n/cm{sup 2} based on the end of 15th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 4.203E+19, 5.232E+19, 6.262E+19 and 7.291E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Kori unit 2 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 49 refs., 35 figs., 48 tabs. (Author)

  6. Performance test for the compressor of 100kW APU

    International Nuclear Information System (INIS)

    Lim, Byeung Jun; Cha, Bong Jun; Yang, Soo Seok; Lee, Kyoung Jin; Baik, Ki Young

    2001-01-01

    The performance test of a centrifugal compressor for APU(Auxiliary Power Unit) which is developed by the collaborative research of KARI and Samsung TechWin has been conducted. The investigated compressor consists of a curved inlet, a centrifugal impeller, a channel diffuser and a plenum chamber. The experiments were carried out in an open-loop centrifugal compressor test rig driven by a turbine. For three different diffusers, overall performance data were obtained at 80%, 90% and 97% of design speed. For the initially designed wedge-type diffuser, test results showed that the compressor was operated at a higher mass flow rate than the design requirement. By reducing the diffuser throat area, the compressor operating range was shifted to lower mass flow rate range. The test result of redesigned wedge-type diffuser showed high pressure loss. To reduce the diffuser loss, diffuser inlet radius was increased and airfoil-type of diffuser was adopted. This airfoil-type diffuser showed reasonal results in terms of design requirement

  7. Revision report about the in-situ tests of 1000 MW unit 5 Kozloduy (Bulgaria)

    International Nuclear Information System (INIS)

    Muzzi, F.

    1995-01-01

    This report refers to the technical revision performed on the technical report about the in-situ tests performed on 1000 Unit 5 nuclear power station of Kozloduy (Bulgaria), within the frame of the IAEA benchmark study for the seismic analysis and testing of an existing Nuclear Power Plant. After a foreword to define the aims of the job and the identification of the scope of the work, a brief description of the plant is made. A brief description of the theory about the modal parameter determination and the soil-structure interaction analysis by experimental tests is made. The following chapters collect some comments about the tests carried out in Kozloduy, with special reference to the general correctness of testing procedure and to data special requirements for the seismic safety margin assessment procedures to be applied on the existing power station

  8. Test results for the Oasis 3C high performance water-pumping windmill

    Energy Technology Data Exchange (ETDEWEB)

    Eggleston, D.M. [DME Engineering, Midland, TX (United States)

    1997-12-31

    The WINDTech International, L.L.C. Oasis 3C, a 3 m diameter, high-performance water-pumping windmill, was tested at the DME Engineering Wind Test Site just south of Midland, Texas from August through December, 1996. This machine utilizes a 3:1 gearbox with rotating counterweights, similar to a conventional oilfield pumping unit, driven by a multibladed rotor. The rotating counterweight system balances most of the pumping loads and reduces gear loads and starting torque by a factor of at least two and often by a factor of four or more. The torque reduction substantially extends gear and bearing life, and reduces wind speeds required for starting by 30 to 50% or more. The O3C was tested pumping from a quiescent fluid depth of 12.2 m (40 ft) from a 28.3 m (93 ft)-deep well, with additional pumping depth simulated using a pressure regulator valve system. A 9.53 cm (3.75 in.) diameter Harbison-Fischer seal-less single-acting piston pump was used to eliminate pump seal friction as a variable, and standard O3C stroke lengths of 30.5 and 15.2 cm (12 and 6 inches) were used. The regulator spring was set to give a maximum stroke rate of 33 strokes per minute. The water pumped was returned to the well after flowing through a settling tank. The tests were performed in accordance with AWEA WECS testing standards. Instrumentation provided 16 channels of data to accurately measure machine performance, including starting wind speeds, flow rates, O3C azimuth, tail furl angle, wind direction tracking errors, RPM, sucker rod loads, and other variables. The most significant performance data is summarized herein. A mathematical model of machine performance was developed that fairly accurately predicts performance for each of three test conditions. The results verify that the O3C is capable of pumping water at wind speeds from 30% to more than 50% lower than comparable un-counterbalanced units.

  9. Unit and integration testing of Lustre programs: a case study from the nuclear industry

    International Nuclear Information System (INIS)

    Thevenod-Fosse, P.

    1998-01-01

    LUSTRE belongs to the class of synchronous data flow languages which have been designed for programming reactive and real-time systems having safety-critical requirements. It is implemented in the SCADE tool. SCADE is a software development environment for real-time systems which consists of a graphical and textual editor, and a C code generator. In previous work, a testing approach specific to LUSTRE programs has been defined, which may be applied at either the unit or integration testing levels of a gradual testing process. The paper reports on an industrial case study we have performed to exemplify the feasibility of the testing strategy. The software module, called SRIC (Source Range Instrumentation channel), was developed by SCHNEIDER ELECTRIC in the SCADE environment. SRIC is extracted from a monitoring software system of a nuclear reactor: it approximates 2600 lines of C code automatically generated by SCADE. Section 2 outlines the testing strategy. Then, Section 3 presents the results related to the program SRIC, for which four testing levels were defined (unit testing followed by three successive integration testing levels). First conclusions and direction for future work are proposed in Section 4. (author)

  10. The EUROBALL neutron wall - design and performance tests of neutron detectors

    CERN Document Server

    Skeppstedt, Ö; Lindström, L; Wadsworth, R; Hibbert, I; Kelsall, N; Jenkins, D; Grawe, H; aGórska, M; Moszynski, M; Sujkowski, Z; Wolski, D; Kapusta, M; Hellström, M; Kalogeropoulos, S; Oner, D; Johnson, A; Cederkäll, J; Klamra, W; Nyberg, J; Weiszflog, M; Kay, J; Griffiths, R; Garces-Narro, J; Pearson, C; Eberth, J

    1999-01-01

    The mechanical design of the EUROBALL neutron wall and neutron detectors, and their performance measured with a sup 2 sup 4 sup 6 sup , sup 2 sup 4 sup 8 Cm fission source are described. The array consists of 15 pseudohexaconical detector units subdivided into three, 149 mm high, hermetically separated segments and a smaller central pentagonal unit subdivided into five segments. The detectors are filled with Bicron BC501A liquid scintillator. Each section of the hexaconical detectors is viewed by a 130 mm diameter Philips XP4512PA photomultiplier while the sections of pentagonal detectors are viewed by Philips XP4312B PMTs. The tests of n-gamma discrimination performed by zero-crossing and time-of-flight methods show a full separation of gamma- and neutron events down to 50 keV recoil electron energy. These tests demonstrate the excellent timing properties of the detectors and an average time resolution of 1.56 ns. The factors determining the efficiency of neutron detectors are discussed. The total efficiency...

  11. Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure. 1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions. 1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution. 1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest. 1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this s...

  12. The missing link? Testing a schema account of unitization.

    Science.gov (United States)

    Tibon, Roni; Greve, Andrea; Henson, Richard

    2018-05-09

    Unitization refers to the creation of a new unit from previously distinct items. The concept of unitization has been used to explain how novel pairings between items can be remembered without requiring recollection, by virtue of new, item-like representations that enable familiarity-based retrieval. We tested an alternative account of unitization - a schema account - which suggests that associations between items can be rapidly assimilated into a schema. We used a common operationalization of "unitization" as the difference between two unrelated words being linked by a definition, relative to two words being linked by a sentence, during an initial study phase. During the following relearning phase, a studied word was re-paired with a new word, either related or unrelated to the original associate from study. In a final test phase, memory for the relearned associations was tested. We hypothesized that, if unitized representations act like schemas, then we would observe some generalization to related words, such that memory would be better in the definition than sentence condition for related words, but not for unrelated words. Contrary to the schema hypothesis, evidence favored the null hypothesis of no difference between definition and sentence conditions for related words (Experiment 1), even when each cue was associated with multiple associates, indicating that the associations can be generalized (Experiment 2), or when the schematic information was explicitly re-activated during Relearning (Experiment 3). These results suggest that unitized associations do not generalize to accommodate new information, and therefore provide evidence against the schema account.

  13. Software Unit Testing during the Development of Digital Reactor Protection System of HTR-PM

    International Nuclear Information System (INIS)

    Guo Chao; Xiong Huasheng; Li Duo; Zhou Shuqiao; Li Jianghai

    2014-01-01

    Reactor Protection System (RPS) of High Temperature Gas-Cooled Reactor - Pebble bed Module (HTR-PM) is the first digital RPS designed and to be operated in the Nuclear Power Plant (NPP) of China, and its development process has receives a lot of concerns around the world. As a 1E-level safety system, the RPS has to be designed and developed following a series of nuclear laws and technical disciplines including software verification and validation (software V&V). Software V&V process demonstrates whether all stages during the software development are performed correctly, completely, accurately, and consistently, and the results of each stage are testable. Software testing is one of the most significant and time-consuming effort during software V&V. In this paper, we give a comprehensive introduction to the software unit testing during the development of RPS in HTR-PM. We first introduce the objective of the testing for our project in the aspects of static testing, black-box testing, and white-box testing. Then the testing techniques, including static testing and dynamic testing, are explained, and the testing strategy we employed is also introduced. We then introduce the principles of three kinds of coverage criteria we used including statement coverage, branch coverage, and the modified condition/decision coverage. As a 1E-level safety software, testing coverage needs to be up to 100% mandatorily. Then we talk the details of safety software testing during software development in HTR-PM, including the organization, methods and tools, testing stages, and testing report. The test result and experiences are shared and finally we draw a conclusion for the unit testing process. The introduction of this paper can contribute to improve the process of unit testing and software development for other digital instrumentation and control systems in NPPs. (author)

  14. Implementing a Nurse Manager Profile to Improve Unit Performance.

    Science.gov (United States)

    Krugman, Mary E; Sanders, Carolyn L

    2016-06-01

    Nurse managers face significant pressures in the rapidly changing healthcare environment. Staying current with multiple sources of data, including reports that detail institutional and unit performance outcomes, is particularly challenging. A Nurse Manager Customized Profile was developed at a western academic hospital to provide a 1-page visual of pertinent data to help managers and director supervisors focus coaching to improve unit performance. Use of the Decisional Involvement Scale provided new insights into measuring manager performance.

  15. Performance Validity Testing in Neuropsychology: Scientific Basis and Clinical Application-A Brief Review.

    Science.gov (United States)

    Greher, Michael R; Wodushek, Thomas R

    2017-03-01

    Performance validity testing refers to neuropsychologists' methodology for determining whether neuropsychological test performances completed in the course of an evaluation are valid (ie, the results of true neurocognitive function) or invalid (ie, overly impacted by the patient's effort/engagement in testing). This determination relies upon the use of either standalone tests designed for this sole purpose, or specific scores/indicators embedded within traditional neuropsychological measures that have demonstrated this utility. In response to a greater appreciation for the critical role that performance validity issues play in neuropsychological testing and the need to measure this variable to the best of our ability, the scientific base for performance validity testing has expanded greatly over the last 20 to 30 years. As such, the majority of current day neuropsychologists in the United States use a variety of measures for the purpose of performance validity testing as part of everyday forensic and clinical practice and address this issue directly in their evaluations. The following is the first article of a 2-part series that will address the evolution of performance validity testing in the field of neuropsychology, both in terms of the science as well as the clinical application of this measurement technique. The second article of this series will review performance validity tests in terms of methods for development of these measures, and maximizing of diagnostic accuracy.

  16. Nearly Efficient Likelihood Ratio Tests of the Unit Root Hypothesis

    DEFF Research Database (Denmark)

    Jansson, Michael; Nielsen, Morten Ørregaard

    Seemingly absent from the arsenal of currently available "nearly efficient" testing procedures for the unit root hypothesis, i.e. tests whose local asymptotic power functions are indistinguishable from the Gaussian power envelope, is a test admitting a (quasi-)likelihood ratio interpretation. We...... show that the likelihood ratio unit root test derived in a Gaussian AR(1) model with standard normal innovations is nearly efficient in that model. Moreover, these desirable properties carry over to more complicated models allowing for serially correlated and/or non-Gaussian innovations....

  17. Testing for purchasing power parity in 21 African countries using several unit root tests

    Science.gov (United States)

    Choji, Niri Martha; Sek, Siok Kun

    2017-04-01

    Purchasing power parity is used as a basis for international income and expenditure comparison through the exchange rate theory. However, empirical studies show disagreement on the validity of PPP. In this paper, we conduct the testing on the validity of PPP using panel data approach. We apply seven different panel unit root tests to test the validity of the purchasing power parity (PPP) hypothesis based on the quarterly data on real effective exchange rate for 21 African countries from the period 1971: Q1-2012: Q4. All the results of the seven tests rejected the hypothesis of stationarity meaning that absolute PPP does not hold in those African Countries. This result confirmed the claim from previous studies that standard panel unit tests fail to support the PPP hypothesis.

  18. Fuel leak testing performance at NPP Jaslovske Bohunice

    International Nuclear Information System (INIS)

    Slugen, V.; Krnac, S.; Smiesko, I.

    1995-01-01

    The NPP Bohunice VVER-440 fuel leak testing experience are relatively extensive in comparison with other VVER-440 users. As the first Europe NPP was adapted Siemens (KWU) in core-sipping equipment to VVER-440 units and since this time were have done these tests also for NPP Paks (Hungary) and NPP Dukovany (Czech Republic). The occurrence of leaking fuel assemblies in NPP is in the last 5 years relatively stabilised and low. A significant difference can be observed between type V-230 (31 leaks) and type V-213 (1 leak). None of of the indicated leaking fuel assemblies has been investigated in the hot cell. Therefore cannot be confirm the effective causes of leak occurrence. Nevertheless, the fuel failure rate and the performance of leak testing in NPP Bohunice are comparable to the world standard at PWR's. 1 tab., 2 figs., 3 refs

  19. Fuel leak testing performance at NPP Jaslovske Bohunice

    Energy Technology Data Exchange (ETDEWEB)

    Slugen, V; Krnac, S [Slovak Technical Univ., Bratislava (Slovakia); Smiesko, I [Nuclear Powr Plant EBO, Jaslovske Bohuce (Slovakia)

    1996-12-31

    The NPP Bohunice VVER-440 fuel leak testing experience are relatively extensive in comparison with other VVER-440 users. As the first Europe NPP was adapted Siemens (KWU) in core-sipping equipment to VVER-440 units and since this time were have done these tests also for NPP Paks (Hungary) and NPP Dukovany (Czech Republic). The occurrence of leaking fuel assemblies in NPP is in the last 5 years relatively stabilised and low. A significant difference can be observed between type V-230 (31 leaks) and type V-213 (1 leak). None of of the indicated leaking fuel assemblies has been investigated in the hot cell. Therefore cannot be confirm the effective causes of leak occurrence. Nevertheless, the fuel failure rate and the performance of leak testing in NPP Bohunice are comparable to the world standard at PWR`s. 1 tab., 2 figs., 3 refs.

  20. Use of Ancillary Tests When Determining Brain Death in Pediatric Patients in the United States.

    Science.gov (United States)

    Lewis, Ariane; Adams, Nellie; Chopra, Arun; Kirschen, Matthew P

    2017-10-01

    Although pediatric brain death guidelines stipulate when ancillary testing should be used during brain death determination, little is known about the way these recommendations are implemented in clinical practice. We conducted a survey of pediatric intensivists and neurologists in the United States on the use of ancillary testing. Although most respondents noted they only performed an ancillary test if the clinical examination and apnea test could not be completed, 20% of 195 respondents performed an ancillary test for other reasons, including (1) to convince a family that objected to the brain death determination that a patient is truly dead (n = 21), (2) personal preference (n = 14), and (3) institutional requirement (n = 5). Our findings suggest that pediatricians use ancillary tests for a variety of reasons during brain death determination. Medical societies and governmental regulatory bodies must reinforce the need for homogeneity in practice.

  1. Multiple unit root tests under uncertainty over the initial condition : some powerful modifications

    NARCIS (Netherlands)

    Hanck, C.

    We modify the union-of-rejection unit root test of Harvey et al. "Unit Root Testing in Practice: Dealing with Uncertainty over the Trend and Initial Condition" (Harvey, Econom Theory 25:587-636, 2009). This test rejects if either of two different unit root tests rejects but controls the inherent

  2. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C. Edward; Klee, Paul M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted

  3. Safety Assessment for transient event occurred during the ASTS test of Hanbit Unit 2

    International Nuclear Information System (INIS)

    Yang, Changkeun; Kim, Yohan; Ha, Sangjun

    2014-01-01

    Safety Injection has been actuated during the ASTS (Automatic Seismic Trip System) test of Hanbit Unit 2 on Feb. 28, 2014. It could be bad effect on system integrity. KHNP has been performed safety assessment of system for effect of Safety Injection (SI) actuation occurred during the ASTS test of hanbit Unit 2. Stable state of nuclear power plant system has been confirmed according to Safety Injection and reactor trip event occurred during the ASTS test of hanbit Unit 2. In the result of system safety assessment, major variables of nuclear power plant are located in optimal range and not exceed safety limit. It remains nuclear fuel and the integrity of the power plant is in a safe condition were conformed. After ASTS action, thermal elimination has been processed throughout the turbine until turbine signal occurrence because ASTS is connected to M-G set in the present hanbit Unit 2. Therefore, Safety Injection signal has been actuated by rapid reduction of Steam Generator pressure. In this paper, it is concluded that consideration of equipment and setpoint is needed for that Safety Injection has been not occurred under the unnecessary situation. Stable state of nuclear power plant system has been confirmed for Safety Injection and reactor trip event occurred during the ASTS test of hanbit Unit 2. In the result of system safety assessment, major variables of nuclear power plant are located in optimal range and not exceed safety limit. It remains nuclear fuel and the integrity of the plant is in a safe condition were conformed. It is concluded that consideration of equipment and setpoint is needed for that Safety Injection has been not occurred under the unnecessary situation

  4. Standard specification for agencies performing nondestructive testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification covers minimum requirements for agencies performing nondestructive testing (NDT). 1.2 When using this specification to assess the capability of, or to accredit NDT agencies, Guide E 1359 shall be used as a basis for the survey. It can be supplemented as necessary with more detail in order to meet the auditor's specific needs. 1.3 This specification can be used as a basis to evaluate testing or inspection agencies, or both, and is intended for use for the qualifying or accrediting, or both, of testing or inspection agencies, public or private. 1.4 The use of SI or inch-pound units, or combination thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to...

  5. SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

    International Nuclear Information System (INIS)

    LaFrance, M; Marsh, S; Hicks, R; O’Donnell-Moran, G

    2015-01-01

    Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits

  6. SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

    Energy Technology Data Exchange (ETDEWEB)

    LaFrance, M; Marsh, S; Hicks, R; O’Donnell-Moran, G [Baystate Health Systems, Inc., Springfield, MA (United States)

    2015-06-15

    Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits.

  7. How explicit and implicit test instructions in an implicit learning task affect performance.

    Directory of Open Access Journals (Sweden)

    Arnaud Witt

    Full Text Available Typically developing children aged 5 to 8 years were exposed to artificial grammar learning. Following an implicit exposure phase, half of the participants received neutral instructions at test while the other half received instructions making a direct, explicit reference to the training phase. We first aimed to assess whether implicit learning operated in the two test conditions. We then evaluated the differential impact of age on learning performances as a function of test instructions. The results showed that performance did not vary as a function of age in the implicit instructions condition, while age effects emerged when explicit instructions were employed at test. However, performance was affected differently by age and the instructions given at test, depending on whether the implicit learning of short or long units was assessed. These results suggest that the claim that the implicit learning process is independent of age needs to be revised.

  8. Digital tape unit test facility software

    Science.gov (United States)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  9. Eyeball test using abdominal ultrasound unit

    International Nuclear Information System (INIS)

    Choi, Chun Kyu; Lee, Yong Woo; Cheung, Hwan

    1984-01-01

    Ultrasonography is a wide diagnostic use for its desirable quality that it causes no radiation hazard to the patient and allows to test him without causing pains, while affording much valued diagnostic information. Since Mundt reported in 1955 that Ultrasonography can be used for testing the eyeball, it has widely been used for clinical purpose, but in Korea many difficulties are being exist in the sonographic evaluation of the eyeball due to storage of the exclusive Ultrasound units for eyeball diagnosis. This treatise describes eyeball test methods along with clinical instances observed by a compound scanner for abdomen scan mounted with an eyeball transducer of a frequency as high as 5 to 7.5MHz and using water bag

  10. Organization and methodology applied to the control of commissioning tests to guarantee safe operation of nuclear units

    International Nuclear Information System (INIS)

    Clausner, J.P.; Jorel, M.

    1990-12-01

    This paper describes the activities of the Safety Analysis Department (DAS), which provides technical support for the French safety authorities in the specific context of analysis and control of startup test programme quality at each of the different stages of the programme. These activities combine to ensure that the objective of the startup tests is reached, in particular that the functions of each safety-related system are guaranteed in all operating configurations, that the performance levels of all components in the system comply with design criteria and that defects revealed during previous tests have been dealt with correctly. The special case of French nuclear facilities, linked to unit standardization, has made it possible to acquire a large amount of experience with the startup of the 900 MWe units and has illustrated the importance of defining a startup test programme. In 1981, a working group, comprising operating organization and safety authority representatives, studied the lessons which had to be learned from 900 MWe unit startup and the improvements which could be made and taken into account in the 1300 MWe unit startup programme. To illustrate the approach adopted by the DAS, we go on to describe the lessons learned from startup of the first 1300 MWe (P4) units

  11. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

    International Nuclear Information System (INIS)

    Létourneau, Daniel; McNiven, Andrea; Keller, Harald; Wang, An; Amin, Md Nurul; Pearce, Jim; Norrlinger, Bernhard; Jaffray, David A.

    2014-01-01

    and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior

  12. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    Science.gov (United States)

    Létourneau, Daniel; Wang, An; Amin, Md Nurul; Pearce, Jim; McNiven, Andrea; Keller, Harald; Norrlinger, Bernhard; Jaffray, David A

    2014-12-01

    apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ± 1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.

  13. Stochastic hydrogeologic units and hydrogeologic properties development for total-system performance assessments. Yucca Mountain Site Characterization Project

    International Nuclear Information System (INIS)

    Schenker, A.R.; Guerin, D.C.; Robey, T.H.; Rautman, C.A.; Barnard, R.W.

    1995-09-01

    A stochastic representation of the lithologic units and associated hydrogeologic parameters of the potential high-level nuclear waste repository are developed for use in performance-assessment calculations, including the Total-System Performance Assessment for Yucca Mountain-SNL Second Iteration (TSPA-1993). A simplified lithologic model has been developed based on the physical characteristics of the welded and nonwelded units at Yucca Mountain. Ten hydrogeologic units are developed from site-specific data (lithologic and geophysical logs and core photographs) obtained from the unsaturated and saturated zones. The three-dimensional geostatistical model of the ten hydrogeologic units is based on indicator-coding techniques and improves on the two-dimensional model developed for TSPA91. The hydrogeologic properties (statistics and probability distribution functions) are developed from the results of laboratory tests and in-situ aquifer tests or are derived through fundamental relationships. Hydrogeologic properties for matrix properties, bulk conductivities, and fractures are developed from existing site specific data. Extensive data are available for matrix porosity, bulk density, and matrix saturated conductivity. For other hydrogeologic properties, the data are minimal or nonexistent. Parameters for the properties are developed as beta probability distribution functions. For the model units without enough data for analysis, parameters are developed as analogs to existing units. A relational, analytic approach coupled with bulk conductivity parameters is used to develop fracture parameters based on the smooth-wall-parallel-plate theory. An analytic method is introduced for scaling small-core matrix properties to the hydrogeologic unit scales

  14. A method for projecting full-scale performance of CO/sub 2/ flooding in the Willard Unit

    International Nuclear Information System (INIS)

    Bilhartz, H.L.; Charlson, G.S.; Stalkup, F.I.; Miller, C.C.

    1985-01-01

    A non-producing CO/sub 2/ flood tertiary recovery test was recently completed in the Willard Unit of Wasson Field. Flood responses during waterflood and alternate injection of CO/sub 2/ and water were monitored at a logging observation well using compensated neutron and pulsed neutron logs. A pressure core was taken to measure residual oil saturations at the test conclusion. The overall objective of the testing was to obtain information for evaluating the potential for full-scale CO/sub 2/ flooding in the unit. Out method for making this evaluation involves: (1) defining CO/sub 2/ flood displacement efficiency and representing this efficiency in a miscible flood reservoir simulator; (2) defining a representative average reservoir description; and (3) projecting full-scale CO/sub 2/ flood performance with the simulator. The paper provides a status report on progress to assess CO/sub 2/ flooding potential for the Willard Unit in this manner

  15. Evaluation of the control system checkout test at 100% power for Yonggwang Nuclear Power Plant Unit 3

    International Nuclear Information System (INIS)

    Kim, Shin Whan; Lee, Joo Han; Baek, Jong Man; Seo, Jong Tae; Lee, Sang Keun; Kang, In Koo; Ju, Hee Wan; Min, Kyung Soo; Kim, Byung Gon

    1995-01-01

    Control system checkout tests at various powers for Yonggwang Nuclear Power Plant Unit 3(YGN3) were performed to demonstrate the accuracies and proper performances of the control systems of the plant. Tested control systems included the feedwater control system, steam bypass control system, reactor regulation system, control element drive mechanism control system, pressurizer level control system, and pressurizer pressure control system. The measured test data during the control system checkout test at 100% power are evaluated. The test results showed that the control systems of YGN 3 properly control system was simulated by using the LTC code which is the performance analysis code for YGN 3 and 4 design. Comparisons of the predicted results with the measured data confirmed that the feedwater control system controls the steam generator level as designed

  16. 40 CFR 63.1571 - How and when do I conduct a performance test or other initial compliance demonstration?

    Science.gov (United States)

    2010-07-01

    ..., according to § 63.7(a)(2)(ix). (b) What are the general requirements for performance test and performance... according to the provisions in § 63.7(a)(2). If you are required to do a performance evaluation or test for a semi-regenerative catalytic reforming unit catalyst regenerator vent, you may do them at the first...

  17. Design and Test Plans for a Non-Nuclear Fission Power System Technology Demonstration Unit

    Science.gov (United States)

    Mason, Lee; Palac, Donald; Gibson, Marc; Houts, Michael; Warren, John; Werner, James; Poston, David; Qualls, Arthur Lou; Radel, Ross; Harlow, Scott

    2012-01-01

    A joint National Aeronautics and Space Administration (NASA) and Department of Energy (DOE) team is developing concepts and technologies for affordable nuclear Fission Power Systems (FPSs) to support future exploration missions. A key deliverable is the Technology Demonstration Unit (TDU). The TDU will assemble the major elements of a notional FPS with a non-nuclear reactor simulator (Rx Sim) and demonstrate system-level performance in thermal vacuum. The Rx Sim includes an electrical resistance heat source and a liquid metal heat transport loop that simulates the reactor thermal interface and expected dynamic response. A power conversion unit (PCU) generates electric power utilizing the liquid metal heat source and rejects waste heat to a heat rejection system (HRS). The HRS includes a pumped water heat removal loop coupled to radiator panels suspended in the thermal-vacuum facility. The basic test plan is to subject the system to realistic operating conditions and gather data to evaluate performance sensitivity, control stability, and response characteristics. Upon completion of the testing, the technology is expected to satisfy the requirements for Technology Readiness Level 6 (System Demonstration in an Operational and Relevant Environment) based on the use of high-fidelity hardware and prototypic software tested under realistic conditions and correlated with analytical predictions.

  18. Tests of an experimental slash ignition unit

    Science.gov (United States)

    James L. Murphy; Harry E. Schimke

    1965-01-01

    A prototype ignition package containing an incendiary powder and designed for slash and brush burning jobs showed some promise, but the unit tested was not superior to such conventional devices as fusees, diesel backpack type flamethrowers, Very pistols, and drip torches.

  19. The Initial Test Programme Features for the Advanced Korean NPPs (Shin–Kori NPP Units 3&4)

    International Nuclear Information System (INIS)

    Sul, Y.S.

    2015-01-01

    Korea has developed the Advanced Power Reactor 1400 (APR1400), an evolutionary pressurised water reactor and has obtained the standard design approval in 2002. As of 2014, eight nuclear power plants (NPPs) are in preparation for operation or under construction, four in Korea (SKN 3&4, SUN 1&2) and four in UAE (BNPP 1, 2, 3&4), and four NPPs are in planning in Korea (SKN 5&6, SUN 3&4). Especially, SKN Units 3&4 are the first construction NPPs for the APR1400 and are currently in the final stage to get Operating Licence (OL). The initial test programme for NPPs begins as systems and components are turned over to the startup organization and ends with completion of the Power Ascension Tests (PATs). For SKN Unit 3, the Pre-core Hot Functional Testing has been successfully completed and the initial fuel loading would proceed after getting OL. The SKN Unit 4 is preparing for the CHT (Cold Hydrostatic Test). The SKN 3&4 has many new and advanced design features and so has developed the test programmes to demonstrate that those advanced design features can be safely operated and the performance levels can be maintained in accordance with approved safety requirements. Among those test programs, the examples of test programs, newly introduced ones compared to the previous NPPs are as follows; – SIT (Safety Injection Tank) Blowdown Test with FD (Fluidic Device) – IRWST (In-Containment Refueling Water Storage Tank) In-Plant Test – POSRV (Pilot Operated Safety Relief Valve) Test – Low Power Physics Testing and PAT considering FOAK (First Of A Kind) unit – Safe Shutdown Test with DCS (Distrubuted Control System) Fail and CMF (Common Mode Failure) for Safety Instrumentation and Control System. (author)

  20. Start up physics tests of units 5 and 6 (WWER 1000) at Kozloduy NPP by comparison with the calculated neutron physics characteristics

    International Nuclear Information System (INIS)

    Antov, A.; Stoyanova, I.

    2008-01-01

    In conjunction with each refuelling shutdown of the reactor core, nuclear design calculations are performed to ensure that the reactor physics characteristics of the new core will be consistent with the safety limits. Prior to return to normal operation, a physics test program is required to determine if the operating characteristics of the core are consistent with the design predictions and to ensure that the core can be operated as designed. Successful completion of the physics test program is demonstrated when the test results agree with the predicted results within predetermined test criteria. Successful completion of the physics test program and successful completion of other tests, which are performed after each refuelling provides assurance that the plant can be operated as designed. The calculated neutron-physics characteristics values of Kozloduy NPP Unit 5 and Unit 6 (WWER 1000) obtained by the computer code package KASKAD are compared with the obtained results during the start up physics tests. The core fuel loading consists of 163 fuel assemblies (FAs). The calculated values are given according to actual experimental conditions of the reactor core during start up physics tests. The report includes comparisons between calculation results by code package KASKAD (BIPR7A) and experimental data values of main neutron-physics characteristics during start up physics tests in selected recent cycles of Kozloduy NPP Unit 5 and Unit 6. (authors)

  1. Start up physics tests of Units 5 and 6 (WWER-1000) at Kozloduy NPP by comparison with the calculated neutron physics characteristics

    International Nuclear Information System (INIS)

    Stoyanova, I.; Antov, A.

    2007-01-01

    In conjunction with each refuelling shutdown of the reactor core, nuclear design calculations are performed to ensure that the reactor physics characteristics of the new core will be consistent with the safety limits. Prior to return to normal operation, a physics test program is required to determine if the operating characteristics of the core are consistent with the design predictions and to ensure that the core can be operated as designed. Successful completion of the physics test program is demonstrated when the test results agree with the predicted results within predetermined test criteria. Successful completion of the physics test program and successful completion of other tests which are performed after each refuelling provides assurance that the plant can be operated as designed. The calculated neutron-physics characteristics values of Kozloduy NPP Unit 5 and Unit 6 (WWER 1000) obtained by the computer code package KASKAD are compared with the obtained results during the start up physics tests. The core fuel loading consists of 163 fuel assemblies. The calculated values are given according to actual experimental conditions of the reactor core during start up physics tests. The report includes comparisons between calculation results by code package KASKAD (BIPR7A) and experimental data values of main neutron-physics characteristics during start up physics tests in selected recent cycles of Kozloduy NPP Unit 5 and Unit 6 (Authors)

  2. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C.E.; Klee, P.M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted. copyright 1997 American Institute of Physics

  3. Start-up test of Fukushima Daini Nuclear Power Station Unit No.3

    International Nuclear Information System (INIS)

    Inomata, Toshio; Umezu, Akira; Kajikawa, Makoto; Koibuchi, Hiroshi; Netsu, Nobuhiko.

    1986-01-01

    In Unit 3 of the Fukushima Nuclear Power Station II (daini), a BWR power plant of output 1,100 MW, commercial operation was started in June 1985. Its start-up test was finished successfully in about nine months. That is, new equipments introduced were demonstration tested. Though the items of testing are increased, the start-up test took short time, resulting in construction period only 54.7 months of the Unit 3, the shortest in the world. During the test, there was no scramming other than the planned. Described are the following: an outline of the Unit 3, the items of its improvement and standardization, including the new equipments, preparations for the start-up test, the start-up test and its evaluation. (Mori, K.)

  4. 40 CFR 60.8 - Performance tests.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Performance tests. 60.8 Section 60.8... PERFORMANCE FOR NEW STATIONARY SOURCES General Provisions § 60.8 Performance tests. (a) Except as specified in... conduct performance test(s) and furnish the Administrator a written report of the results of such...

  5. Effect of Cooling Units on the Performance of an Automotive Exhaust-Based Thermoelectric Generator

    Science.gov (United States)

    Su, C. Q.; Zhu, D. C.; Deng, Y. D.; Wang, Y. P.; Liu, X.

    2017-05-01

    Currently, automotive exhaust-based thermoelectric generators (AETEGs) are a hot topic in energy recovery. In order to investigate the influence of coolant flow rate, coolant flow direction and cooling unit arrangement in the AETEG, a thermoelectric generator (TEG) model and a related test bench are constructed. Water cooling is adopted in this study. Due to the non-uniformity of the surface temperature of the heat source, the coolant flow direction would affect the output performance of the TEG. Changing the volumetric flow rate of coolant can increase the output power of multi-modules connected in series or/and parallel as it can improve the temperature uniformity of the cooling unit. Since the temperature uniformity of the cooling unit has a strong influence on the output power, two cooling units are connected in series or parallel to research the effect of cooling unit arrangements on the maximum output power of the TEG. Experimental and theoretical analyses reveal that the net output power is generally higher with cooling units connected in parallel than cooling units connected in series in the cooling system with two cooling units.

  6. Identification of common allergens for united airway disease by skin prick test

    Directory of Open Access Journals (Sweden)

    Vikas Deep Mishra

    2016-01-01

    Full Text Available Objective: Identification of common allergens by skin prick test in patients of united airway disease. Materials and Methods: Skin prick test was performed in 60 patients of United Airway Disease to identify the common allergens. A total of 62 allergens consisting of 36 types of pollen, 5 fungi, 4 insects, 8 type of dusts, 4 dander, 3 fabrics, Dust mite and Parthenium leaves were tested. Result: Most common allergens were Dust mite (60% followed by Parthenium leaves (45%, insects (18.75%, pollen (14.81%, dust allergens (8.51%, fabrics (8.33%, fungi (5.66%, dander (5%. Most common insect allergens were cockroach (female (30%, cockroach (male (23.33%. Common pollens were Ricinus communis (28.33%, Amaranthus spinosus (28.33%, Parthenium hysterophorus (26.66%, Eucalyptus tereticornis (26.66% and Cynodon dactylon (25%. Common dust allergens were house dust (21.66%, paper dust (11.66% and cotton mill dust (10%. Among fabrics kapok cotton (13.33% showed maximum positivity. Among fungi Aspergillus fumigatus (10% followed by A. niger (6.66% were most common. In animal dander group common ones were cat dander followed by dog dander. Conclusion: In conclusion it can be said that the knowledge drawn by above study will help to treat patients by immunotherapy or avoidance strategy.

  7. 14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine tests in auxiliary power unit (APU... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...

  8. A Nonlinear Unit Root Test in the Presence of an Unknown Break

    OpenAIRE

    Popp, Stephan

    2008-01-01

    The Perron test is the most commonly applied procedure to test for a unit root in the presence of a structural break of unknown timing in the trend function. Deriving the Perron-type test regression from an unobserved component model, it is shown that the test regression in fact is nonlinear in coefficient. Taking account of the nonlinearity leads to a test with properties that are exclusively assigned to Schmidt-Phillips LM-type unit root tests.

  9. Calculation method for the seasonal performance of heat pump compact units and validation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Wemhoener, C.; Dott, R.; Afjei, Th. [University of Applied Sciences Northwestern Switzerland, Institute of Energy in Buildings, Muttenz (Switzerland); Huber, H.; Helfenfinger, D.; Keller, P.; Furter, R. [University of Applied Sciences Lucerne (HTA), Test center HLKS, Horw (Switzerland)

    2007-02-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) takes a look at compact heat pump units that have been developed for the heating of low energy consumption houses built to MINERGIE or MINERGIE-P standards. These units, which combine the functions of space heating, domestic hot water preparation and ventilation in one unit are described. A testing procedure developed at the University of Applied Science in Lucerne, Switzerland, using a test rig for the measurement of the seasonal performance factor (SPF) is described. A calculation method based on temperature classes for the calculation of the SPF of combined heat pump systems for space heating and domestic hot water preparation that was developed by the Institute of Energy in Buildings at the University of Applied Sciences Northwestern Switzerland is examined. Two pilot plants allowing detailed field monitoring of two compact units are described. One pilot plant installed in a single-family house built to MINERGIE standard in Gelterkinden, Switzerland, provided data on a compact unit. These results of measurements made on this and a further installation in a MINERGIE-P ultra-low energy consumption house in Zeiningen, Switzerland, are presented and discussed. Calculation methods, including exergy considerations are reviewed and their validation is discussed.

  10. Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator

    DEFF Research Database (Denmark)

    Diakos, Konstantinos; Wu, Qiuwei; Nielsen, Arne Hejde

    2014-01-01

    that is able to derive and communicate synchrophasor measurements of different parts of the power network and the development of tests, according to IEEE standards, that evaluate the performance of PMUs and PDCs. The tests are created by using a Real Time Digital Simulation (RTDS) system. The results obtained......The main focus of the electrical engineers nowadays, is to develop a smart grid that is able to monitor, evaluate and control the power system operation. The integration of Intelligent Electronic Devices (IED s) to the power network, is a strong indication of the inclination to lead the power...... network to a more reliable, secure and economic operation. The implementation of these devices though, demands the warranty of a secure operation and high-accuracy performance. This paper describes the procedure of establishing a PMU (Phasor Measurement Unit)–PDC (Phasor Data Concentrator) platform...

  11. Closure Plan for Corrective Action Unit 110: Area 3 RWMS U-3ax/bl Disposal Unit, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    Fitzmaurice, T. M.

    2000-01-01

    This Closure Plan has been prepared for the Area 3 RWMS U-3ax/bl Disposal Unit Corrective Action Unit 110 in accordance with the Federal Facility and Consent Order (Nevada Division of Environmental Protection [NDEP] et al., 1996). The U-3ax/bl is a historic disposal unit within the Area 3 Radioactive Waste Management Site located on the Nevada Test Site (NTS). The unit, which was formed by excavating the area between two subsidence craters (U-3ax and U-3bl), was operationally closed in 1987. The U-3ax/bl disposal unit is scheduled for permanent closure under the Resource Conservation and Recovery Act as a hazardous waste landfill. Existing records indicate that, from July 1968 to December 1987, U-3ax/bl received 2.3 x 10 5 cubic meters (8.12 x 10 6 cubic feet) of waste. NTS nuclear device testing generated approximately 95 percent of the total volume disposed of in U-3ax/bl, the majority of which came from the Waste Consolidation Project (80 percent of the total volume) (Elletson and Johnejack, 1995). Area 3 is located in Yucca Flat, within the northeast quadrant of the NTS. The Yucca Flat watershed is a structurally closed basin encompassing an area of approximately 780 square kilometers (300 square miles). The structural geomorphology of Yucca Flat is typical of the Basin and Range Physiographic Province. Yucca Flat lies in one of the most arid regions of the country. Water balance calculations for Area 3 indicate that it is continuously in a state of moisture deficit. The U-3ax/bl Disposal Unit will be closed in place by installing a Resource Conservation and Recovery Act equivalent cover. Following cover construction a fence will be installed around the cover to prevent accidental damage to the cover. Post-closure monitoring will consist of site inspections to determine the condition of the engineered cover and cover performance monitoring using Time-Domain Reflectometry arrays to monitor moisture migration in the cover. Any identified maintenance and repair

  12. Closure Plan for Corrective Action Unit 110: Area 3 RWMS U-3ax/bl Disposal Unit, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    T. M. Fitzmaurice

    2000-08-01

    This Closure Plan has been prepared for the Area 3 RWMS U-3ax/bl Disposal Unit Corrective Action Unit 110 in accordance with the Federal Facility and Consent Order (Nevada Division of Environmental Protection [NDEP] et al., 1996). The U-3ax/bl is a historic disposal unit within the Area 3 Radioactive Waste Management Site located on the Nevada Test Site (NTS). The unit, which was formed by excavating the area between two subsidence craters (U-3ax and U-3bl), was operationally closed in 1987. The U-3ax/bl disposal unit is scheduled for permanent closure under the Resource Conservation and Recovery Act as a hazardous waste landfill. Existing records indicate that, from July 1968 to December 1987, U-3ax/bl received 2.3 x 10{sup 5} cubic meters (8.12 x 10{sup 6} cubic feet) of waste. NTS nuclear device testing generated approximately 95 percent of the total volume disposed of in U-3ax/bl, the majority of which came from the Waste Consolidation Project (80 percent of the total volume) (Elletson and Johnejack, 1995). Area 3 is located in Yucca Flat, within the northeast quadrant of the NTS. The Yucca Flat watershed is a structurally closed basin encompassing an area of approximately 780 square kilometers (300 square miles). The structural geomorphology of Yucca Flat is typical of the Basin and Range Physiographic Province. Yucca Flat lies in one of the most arid regions of the country. Water balance calculations for Area 3 indicate that it is continuously in a state of moisture deficit. The U-3ax/bl Disposal Unit will be closed in place by installing a Resource Conservation and Recovery Act equivalent cover. Following cover construction a fence will be installed around the cover to prevent accidental damage to the cover. Post-closure monitoring will consist of site inspections to determine the condition of the engineered cover and cover performance monitoring using Time-Domain Reflectometry arrays to monitor moisture migration in the cover. Any identified maintenance and

  13. Testing of an End-Point Control Unit Designed to Enable Precision Control of Manipulator-Coupled Spacecraft

    Science.gov (United States)

    Montgomery, Raymond C.; Ghosh, Dave; Tobbe, Patrick A.; Weathers, John M.; Manouchehri, Davoud; Lindsay, Thomas S.

    1994-01-01

    This paper presents an end-point control concept designed to enable precision telerobotic control of manipulator-coupled spacecraft. The concept employs a hardware unit (end-point control unit EPCU) that is positioned between the end-effector of the Space Shuttle Remote Manipulator System and the payload. Features of the unit are active compliance (control of the displacement between the end-effector and the payload), to allow precision control of payload motions, and inertial load relief, to prevent the transmission of loads between the end-effector and the payload. This paper presents the concept and studies the active compliance feature using a simulation and hardware. Results of the simulation show the effectiveness of the EPCU in smoothing the motion of the payload. Results are presented from initial, limited tests of a laboratory hardware unit on a robotic arm testbed at the l Space Flight Center. Tracking performance of the arm in a constant speed automated retraction and extension maneuver of a heavy payload with and without the unit active is compared for the design speed and higher speeds. Simultaneous load reduction and tracking performance are demonstrated using the EPCU.

  14. Testing for Unit Roots in Market Shares

    NARCIS (Netherlands)

    Franses, P.H.B.F.; Srinivasan, S.; Boswijk, H.P.

    2001-01-01

    A unique characteristic of marketing data sets is the logical consistency requirement in market share models that market shares are bounded by 0 and 1, and they sum to unity. To take account of this logical consistency requirement, we propose to test for unit roots in individual market share series

  15. On-line PWR RHR pump performance testing following motor and impeller replacement

    International Nuclear Information System (INIS)

    DiMarzo, J.T.

    1996-01-01

    On-line maintenance and replacement of safety-related pumps requires the performance of an inservice test to determine and confirm the operational readiness of the pumps. In 1995, major maintenance was performed on two Pressurized Water Reactor (PWR) Residual Heat Removal (RHR) Pumps. A refurbished spare motor was overhauled with a new mechanical seal, new motor bearings and equipped with pump's 'B' impeller. The spare was installed into the 'B' train. The motor had never been run in the system before. A pump performance test was developed to verify it's operational readiness and determine the in-situ pump performance curve. Since the unit was operating, emphasis was placed on conducting a highly accurate pump performance test that would ensure that it satisfied the NSSS vendors accident analysis minimum acceptance curve. The design of the RHR System allowed testing of one train while the other was aligned for normal operation. A test flow path was established from the Refueling Water Storage Tank (RWST) through the pump (under test) and back to the RWST. This allowed staff to conduct a full flow range pump performance test. Each train was analyzed and an expression developed that included an error vector term for the TDH (ft), pressure (psig), and flow rate (gpm) using the variance error vector methodology. This method allowed the engineers to select a test instrumentation system that would yield accurate readings and minimal measurement errors, for data taken in the measurement of TDH (P,Q) versus Pump Flow Rate (Q). Test results for the 'B' Train showed performance well in excess of the minimum required. The motor that was originally in the 'B' train was similarly overhauled and equipped with 'A' pump's original impeller, re-installed in the 'A' train, and tested. Analysis of the 'A' train results indicate that the RHR pump's performance was also well in excess of the vendors requirements

  16. On-line PWR RHR pump performance testing following motor and impeller replacement

    Energy Technology Data Exchange (ETDEWEB)

    DiMarzo, J.T.

    1996-12-01

    On-line maintenance and replacement of safety-related pumps requires the performance of an inservice test to determine and confirm the operational readiness of the pumps. In 1995, major maintenance was performed on two Pressurized Water Reactor (PWR) Residual Heat Removal (RHR) Pumps. A refurbished spare motor was overhauled with a new mechanical seal, new motor bearings and equipped with pump`s `B` impeller. The spare was installed into the `B` train. The motor had never been run in the system before. A pump performance test was developed to verify it`s operational readiness and determine the in-situ pump performance curve. Since the unit was operating, emphasis was placed on conducting a highly accurate pump performance test that would ensure that it satisfied the NSSS vendors accident analysis minimum acceptance curve. The design of the RHR System allowed testing of one train while the other was aligned for normal operation. A test flow path was established from the Refueling Water Storage Tank (RWST) through the pump (under test) and back to the RWST. This allowed staff to conduct a full flow range pump performance test. Each train was analyzed and an expression developed that included an error vector term for the TDH (ft), pressure (psig), and flow rate (gpm) using the variance error vector methodology. This method allowed the engineers to select a test instrumentation system that would yield accurate readings and minimal measurement errors, for data taken in the measurement of TDH (P,Q) versus Pump Flow Rate (Q). Test results for the `B` Train showed performance well in excess of the minimum required. The motor that was originally in the `B` train was similarly overhauled and equipped with `A` pump`s original impeller, re-installed in the `A` train, and tested. Analysis of the `A` train results indicate that the RHR pump`s performance was also well in excess of the vendors requirements.

  17. Inspection system performance test procedure

    International Nuclear Information System (INIS)

    Jensen, C.E.

    1995-01-01

    This procedure establishes requirements to administer a performance demonstration test. The test is to demonstrate that the double-shell tank inspection system (DSTIS) supplied by the contractor performs in accordance with the WHC-S-4108, Double-Shell Tank Ultrasonic Inspection Performance Specification, Rev. 2-A, January, 1995. The inspection system is intended to provide ultrasonic (UT) and visual data to determine integrity of the Westinghouse Hanford Company (WHC) site underground waste tanks. The robotic inspection system consists of the following major sub-systems (modules) and components: Mobile control center; Deployment module; Cable management assembly; Robot mechanism; Ultrasonic testing system; Visual testing system; Pneumatic system; Electrical system; and Control system

  18. Testing the system detection unit for measuring solid minerals bulk density

    Science.gov (United States)

    Voytyuk, I. N.; Kopteva, A. V.

    2017-10-01

    The paper provides a brief description of the system for measuring flux per volume of solid minerals via example of mineral coal. The paper discloses the operational principle of the detection unit. The paper provides full description of testing methodology, as well as practical implementation of the detection unit testing. This paper describes the removal of two data arrays via the channel of scattered anddirect radiation for the detection units of two generations. This paper describes Matlab software to determine the statistical characteristics of the studied objects. The mean value of pulses per cycles, and pulse counting inaccuracy relatively the mean value were determined for the calculation of the stability account of the detection units.

  19. Efficient Market Hypothesis in South Africa: Evidence from Linear and Nonlinear Unit Root Tests

    Directory of Open Access Journals (Sweden)

    Andrew Phiri

    2015-12-01

    Full Text Available This study investigates the weak form efficient market hypothesis (EMH for five generalized stock indices in the Johannesburg Stock Exchange (JSE using weekly data collected from 31st January 2000 to 16th December 2014. In particular, we test for weak form market efficiency using a battery of linear and nonlinear unit root testing procedures comprising of the classical augmented Dickey-Fuller (ADF tests, the two-regime threshold autoregressive (TAR unit root tests described in Enders and Granger (1998 as well as the three-regime unit root tests described in Bec, Salem, and Carrasco (2004. Based on our empirical analysis, we are able to demonstrate that whilst the linear unit root tests advocate for unit roots within the time series, the nonlinear unit root tests suggest that most stock indices are threshold stationary processes. These results bridge two opposing contentions obtained from previous studies by concluding that under a linear framework the JSE stock indices offer support in favour of weak form market efficiency whereas when nonlinearity is accounted for, a majority of the indices violate the weak form EMH.

  20. Commercial landscape of noninvasive prenatal testing in the United States.

    Science.gov (United States)

    Agarwal, Ashwin; Sayres, Lauren C; Cho, Mildred K; Cook-Deegan, Robert; Chandrasekharan, Subhashini

    2013-06-01

    Cell-free fetal DNA-based noninvasive prenatal testing (NIPT) could significantly change the paradigm of prenatal testing and screening. Intellectual property (IP) and commercialization promise to be important components of the emerging debate about clinical implementation of these technologies. We have assembled information about types of testing, prices, turnaround times, and reimbursement of recently launched commercial tests in the United States from the trade press, news articles, and scientific, legal, and business publications. We also describe the patenting and licensing landscape of technologies underlying these tests and ongoing patent litigation in the United States. Finally, we discuss how IP issues may affect clinical translation of NIPT and their potential implications for stakeholders. Fetal medicine professionals (clinicians and researchers), genetic counselors, insurers, regulators, test developers, and patients may be able to use this information to make informed decisions about clinical implementation of current and emerging noninvasive prenatal tests. © 2013 John Wiley & Sons, Ltd.

  1. Proof of Performance Test Report MANTIS

    National Research Council Canada - National Science Library

    2005-01-01

    ... (NVESD), Humanitarian Demining Branch (HD), the assessment was conducted by HD staff members and supported by engineers from the United Kingdom under the auspices of the International Evaluation Test Program for Humanitarian Demining (ITEP...

  2. Double-shell tank integrity assessments ultrasonic test equipment performance test

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, D.C.

    1996-09-26

    A double-shell tank (DST) inspection (DSTI) system was performance tested over three months until August 1995 at Pittsburgh, Pennsylvania, completing a contract initiated in February 1993 to design, fabricate, and test an ultrasonic inspection system intended to provide ultrasonic test (UT) and visual data to determine the integrity of 28 DSTs at Hanford. The DSTs are approximately one-million-gallon underground radioactive-waste storage tanks. The test was performed in accordance with a procedure (Jensen 1995) that included requirements described in the contract specification (Pfluger 1995). This report documents the results of tests conducted to evaluate the performance of the DSTI system against the requirements of the contract specification. The test of the DSTI system also reflects the performance of qualified personnel and operating procedures.

  3. Operating performance of LWR nuclear generating units

    International Nuclear Information System (INIS)

    Pia, S.

    1984-01-01

    This work aims at reviewing, on the basis of historical data, the operational problem areas which explain the degree of availability and productivity achieved up to now by nuclear power plants in commercial operation in the world. The operating performance data of nuclear power plants area analysed with respect to plant type, size and other significant reference parameters and they are evaluated also by comparison with fossil generating unit data. Major performance indices data are presented for both nuclear and fossil units type and distribution of outage causes. Unplanned full outages caused by nuclear power plant equipment and components failure are particulary emphasized. The trend for unplanned full outages due to the failure of components shows decreasing numerical values in 1981 with respect to the previous years. But this result should be weighed with the increasing plant unavailability hours needed for maintenance and repair action (chiefly preventive maintenance on critical components). This means that the number and downtime of forced outage must be drastically reduced for economic reasons (production losses and problems associated with the unavailable unit unplanned replacement) as well as for plant safe and reliable operation (sudden unavailability of key components and frequency of transients associated with plant shutdown and routine startup operation)

  4. Application of controllable unit approach (CUA) to performance-criterion-based nuclear material control and accounting

    International Nuclear Information System (INIS)

    Foster, K.W.; Rogers, D.R.

    1979-01-01

    The Nuclear Regulatory Commission is considering the use of maximum-loss performance criteria as a means of controlling SNM in nuclear plants. The Controllable Unit Approach to material control and accounting (CUA) was developed by Mound to determine the feasibility of controlling a plant to a performance criterion. The concept was tested with the proposed Anderson, SC, mixed-oxide plant, and it was shown that CUA is indeed a feasible method for controlling a complex process to a performance criterion. The application of CUA to an actual low-enrichment plant to assist the NRC in establishing performance criteria for uranium processes is discussed. 5 refs

  5. Assessing the Performance of Business Unit Managers

    NARCIS (Netherlands)

    Bouwens, J.F.M.G.; van Lent, L.A.G.M.

    2006-01-01

    Using a sample of 140 managers, we investigate the use of various performance metrics in determining the periodic assessment, bonus decisions, and career paths of business unit managers.We show that the weight on accounting return measures is associated with the authority of these managers, and we

  6. Test planning and performance

    International Nuclear Information System (INIS)

    Zola, Maurizio

    2001-01-01

    Testing plan should include Safety guide Q4 - Inspection and testing - A testing plan should be prepared including following information: General information (facility name, item or system reference, procurement document reference, document reference number and status, associated procedures and drawings); A sequential listing of all testing activities; Procedure, work instruction, specification or standard to be followed in respect of each operation and test; Acceptance criteria; Identification of who is performing tests; Identification of hold points; Type of records to be prepared for each test; Persons and organizations having authority for final acceptance. Proposed activities sequence is: visual, electrical and mechanical checks; environmental tests (thermal aging, vibrations aging, radioactive aging); performance evaluation in extreme conditions; dynamic tests with functional checks; final electrical and mechanical checks The planning of the tests should always be performed taking into account an interpretative model: a very tight cooperation is advisable between experimental people and numerical people dealing with the analysis of more or less complex models for the seismic assessment of structures and components. Preparatory phase should include the choice of the following items should be agreed upon with the final user of the tests: Excitation points, Excitation types, Excitation amplitude with respect to frequency, Measuring points. Data acquisition, recording and storage, should take into account the characteristics of the successive data processing: to much data can be cumbersome to be processed, but to few data can make unusable the experimental results. The parameters for time history acquisition should be chosen taking into account data processing: for Shock Response Spectrum calculation some special requirements should be met: frequency bounded signal, high frequency sampling, shock noise. For stationary random-like excitation, the sample length

  7. On the asymptotic distribution of a unit root test against ESTAR alternatives

    NARCIS (Netherlands)

    Hanck, Christoph

    We derive the null distribution of the nonlinear unit root test proposed in Kapetanios et al. [Kapetanios, G., Shin, Y., Snell, A., 2003. Testing for a unit root in the nonlinear STAR framework, journal of Econometrics 112, 359-379] when nonzero means or both means and deterministic trends are

  8. Uniform peanut performance test 2017

    Science.gov (United States)

    The Uniform Peanut Performance Tests (UPPT) are designed to evaluate the commercial potential of advanced breeding peanut lines not formally released. The tests are performed in ten locations across the peanut production belt. In this study, 2 controls and 14 entries were evaluated at 8 locations....

  9. Startup physics tests at Temelin NPP, Unit 1

    International Nuclear Information System (INIS)

    Sedlacek, M.; Minarcin, M.; Toth, L.; Elko, M.; Hascik, R.

    2002-01-01

    The objective, scope and proceedings of the physics tests of Temelin NPP, Unit 1 physical commissioning are given in this paper. Furthermore, some results of selected physics tests are presented: reactor initial criticality test, determination of reactor power range for physics testing, measurement of control rod cluster assembly group no. 10 reactivity worth in case of limitation system LS(a) actuation, control rod cluster assembly system reactivity worth measurement with single rod cluster assembly of greatest reactivity worth stuck in fully withdrawn position, measurement of differential reactivity worth of control rod cluster assembly group no. 9, boron 'endpoint' determination and measurement of power reactivity coefficient (Authors)

  10. Thermal performance of a PCM thermal storage unit

    Energy Technology Data Exchange (ETDEWEB)

    Liu Ming; Bruno, Frank; Saman, Wasim [Sustainable Energy Centre, Inst. for Sustainable Systems and Technologies, Univ. of South Australia, Mawson Lakes, Adelaide (Australia)

    2008-07-01

    The thermal performance of a PCM thermal storage unit (TSU) is studied numerically and experimentally. The TSU under analysis consists of several flat slabs of phase change material (PCM) with melting temperature of -26.7 C. Liquid heat transfer fluid (HTF) passes between the slabs to charge and discharge the storage unit. A one dimensional mathematical model was employed to analyze the transient thermal behavior of the storage unit during the melting and freezing processes. The model takes into consideration the temperature variations in the wall along the flow direction of the HTF. The paper compares the experimental and numerical simulation results in terms of HTF outlet temperatures during the melting period. (orig.)

  11. Cyclone Boiler Field Testing of Advanced Layered NOx Control Technology in Sioux Unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Marc A. Cremer; Bradley R. Adams

    2006-06-30

    A four week testing program was completed during this project to assess the ability of the combination of deep staging, Rich Reagent Injection (RRI), and Selective Non-Catalytic Reduction (SNCR) to reduce NOx emissions below 0.15 lb/MBtu in a cyclone fired boiler. The host site for the tests was AmerenUE's Sioux Unit 1, a 500 MW cyclone fired boiler located near St. Louis, MO. Reaction Engineering International (REI) led the project team including AmerenUE, FuelTech Inc., and the Electric Power Research Institute (EPRI). This layered approach to NOx reduction is termed the Advanced Layered Technology Approach (ALTA). Installed RRI and SNCR port locations were guided by computational fluid dynamics (CFD) based modeling conducted by REI. During the parametric testing, NOx emissions of 0.12 lb/MBtu were achieved consistently from overfire air (OFA)-only baseline NOx emissions of 0.25 lb/MBtu or less, when firing the typical 80/20 fuel blend of Powder River Basin (PRB) and Illinois No.6 coals. From OFA-only baseline levels of 0.20 lb/MBtu, NOx emissions of 0.12 lb/MBtu were also achieved, but at significantly reduced urea flow rates. Under the deeply staged conditions that were tested, RRI performance was observed to degrade as higher blends of Illinois No.6 were used. NOx emissions achieved with ALTA while firing a 60/40 blend were approximately 0.15 lb/MBtu. NOx emissions while firing 100% Illinois No.6 were approximately 0.165 lb/MBtu. Based on the performance results of these tests, economics analyses of the application of ALTA to a nominal 500 MW cyclone unit show that the levelized cost to achieve 0.15 lb/MBtu is well below 75% of the cost of a state of the art SCR.

  12. Testing for seasonal unit roots in monthly panels of time series

    NARCIS (Netherlands)

    R.M. Kunst (Robert); Ph.H.B.F. Franses (Philip Hans)

    2009-01-01

    textabstractWe consider the problem of testing for seasonal unit roots in monthly panel data. To this aim, we generalize the quarterly CHEGY test to the monthly case. This parametric test is contrasted with a new nonparametric test, which is the panel counterpart to the univariate RURS test that

  13. Unit testing, model validation, and biological simulation.

    Science.gov (United States)

    Sarma, Gopal P; Jacobs, Travis W; Watts, Mark D; Ghayoomie, S Vahid; Larson, Stephen D; Gerkin, Richard C

    2016-01-01

    The growth of the software industry has gone hand in hand with the development of tools and cultural practices for ensuring the reliability of complex pieces of software. These tools and practices are now acknowledged to be essential to the management of modern software. As computational models and methods have become increasingly common in the biological sciences, it is important to examine how these practices can accelerate biological software development and improve research quality. In this article, we give a focused case study of our experience with the practices of unit testing and test-driven development in OpenWorm, an open-science project aimed at modeling Caenorhabditis elegans. We identify and discuss the challenges of incorporating test-driven development into a heterogeneous, data-driven project, as well as the role of model validation tests, a category of tests unique to software which expresses scientific models.

  14. DEVELOPMENT OF PERFORMANCE ASSESSMENT INSTRUMENT FOR NURSES BASED ON WEB IN INPATIENT UNIT

    Directory of Open Access Journals (Sweden)

    Aprilia Nuryanti

    2017-06-01

    Full Text Available Introduction: Performance assessment instrument will be problematic when it is not representative in describing the competency because it is not obvious indicators and inappropriate performance standard to nursing’s task. The purpose of this study is to develop nurses’ performance assessment instrument based on the web from multi sources assessment inpatient unit at SMC Hospital. Methods: This study had two phases. The first phase was an explanatory overview of the performance assessment system using questionnaires completed by 53 respondents of nurses, selected by purposive sampling. Instrument development based on FGD with six decision makers in the hospital. Validity was tested by Pearson Product Moment Correlation and reliability of instrument’s was tested by alpha Cronbach. The second phase was socialization and instrument test to observe the quality of instrument using a questionnaire by 47 respondents and recommendations made by 8 participants of FGD. The samples were selected by purposive sampling technique. Performance assessment system was moderate at 58.49%. All questions which aimed to measure the performance of nurses were valid and reliable. The quality of nurses’ performance assessment instruments based on the web was a good category, which was functionality: 81.60; reliability: 78.16; efficiency: 80.85; usability: 81.70 and portability: 81.70. Results: The result was a web-based assessment format, scoring with Likert scale, resource assessment by the direct supervisor which was a multisource evaluator, the development of performance graph, and confidentiality of data on the database server. Discussion: Recommendations for hospital is to make policy based on the final value of the performance assessment by the supervisor which was multisource feedback and it needs a global writing on a form of performance assessment result.

  15. Income and CO2 emissions: Evidence from panel unit root and cointegration tests

    International Nuclear Information System (INIS)

    Lee, C.-C.; Lee, J.-D.

    2009-01-01

    This paper re-investigates the stationarity properties of per capita carbon dioxide (CO 2 ) emissions and real Gross Domestic Product (GDP) per capita for 109 countries within seven regional panel sets covering 1971-2003. We apply the recent unit-root test of the panel seemingly unrelated regressions augmented Dickey-Fuller (SURADF) test developed by Breuer et al. [2001. Misleading inferences from panel unit-root tests with an illustration from purchasing power parity. Review of International Economics 9, 482-493; 2002. Series-specific unit-root tests with panel data, Oxford Bulletin of Economics and Statistics 64, 527-546]. The panel SURADF test accounts for the presence of cross-country correlations in the data, and the parameters in the panel specification vary across countries. More importantly, this test allows us to identify how many and which members of the panel contain a unit root. Overall, our empirical results illustrate that real GDP and CO 2 emissions in these countries are a mixture of I(0) and I(1) processes, and that the traditional panel unit-root tests could lead to misleading inferences as well as the conduct of cointegration analysis being perhaps inappropriate. The results of our analysis carry critical implications for the modeling of CO 2 emissions and GDP because of the different orders of integration for the two variables

  16. The 5th surveillance testing for Kori unit 1 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwun Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-08-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed primarily by Korea Atomic Energy Research Institute and Westinhouse corporation partially involved in testing and calculation data evaluation in order to obtain reliable test result. Fast neutron fluences for capsule V, T, S, R and P were 5.087E+18, 1.115E+19, 1.228E+19, 2.988E+19, and 3.938E+19n/cm2, respectively. The bias factor, the ratio of calculation/measurement, was 0.940 for the 1st through 5th testing and the calculational uncertainty, 7% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.9846E+19n/cm{sup 2} based on the end of 17th fuel cycle and it was predicted that the fluences of vessel inside surface at 24, 32, 40 and 48EFPY would reach 3.0593E+19, 4.0695E+19, 5.0797E+19 and 6.0900E+19n/cm{sup 2} based on the current calculation. PTS analysis for Kori unit 1 showed that 27.93EFPY was the threshold value for 300 deg F requirement. 71 refs., 33 figs., 52 tabs. (Author)

  17. Are Current Accounts of Asian Economies Mean-reverting?: Nonlinear Unit Root Test Approach

    Directory of Open Access Journals (Sweden)

    Bonghan Kim

    2005-12-01

    Full Text Available This paper tests the mean reverting property of current account in the financial crisis-affected 5 counties of southeast Asia using nonlinear unit root tests of Park and shintani(2004. Our approach is based on the idea that a conventional unit root test has lower power in detecting the nonlinear mean reverting behavior if the current account follows a nonlinear mean reversion process. We obtained following empirical results. First, for the pre-crisis period (1981Q1-1996Q4, the current accounts of Indonesia, Malaysia and Philippines are mean-reverting but those of Korea and Thailand are not mean-reverting. Second, for the full sample period (1981Q1-2003Q4, the ADF test fails to reject the unit root of the current account in all countries except Philippines. However, unit root is rejected in favor of nonlinear mean reversion except Thailand. This nonlinear unit root test result implies that crisis-affected Asian countries except Thailand have sustainable paths of current accounts. Third, when the current accounts of East Asian countries are nonlinear mean-reverting, the mean reverting process can be well described by the ESTAR model, instead of the DTAR or DLSTAR model. The nonlinear unit root test results imply smooth nonlinear mean-reversion behaviors of East Asian current accounts. Finally, the shape of estimated impulse response functions becomes steeper as the size of shock increases, which is the very characteristic of the nonlinear process.

  18. On the non-existence of a Bartlett correction for unit root tests

    DEFF Research Database (Denmark)

    Jensen, Jens Ledet; Wood, Andrew T.A.

    1997-01-01

    There has been considerable recent interest in testing for a unit root in autoregressive models, especially in the context of cointegration models in econometrics. The likelihood ratio test for a unit root has non-standard asymptotic behaviour. In particular, when the errors are Gaussian, the lim...... for improved distributional approximations, and the question of whether W admits a Bartlett correction is of interest. In this note we establish that a Bartlett correction does not exist in the simplest unit root model. © 1997 Elsevier Science B.V....

  19. 40 CFR 63.344 - Performance test requirements and test methods.

    Science.gov (United States)

    2010-07-01

    ... electroplating tanks or chromium anodizing tanks. The sampling time and sample volume for each run of Methods 306... Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test... Emissions From Decorative and Hard Chromium Electroplating and Anodizing Operations,” appendix A of this...

  20. Making things happen through challenging goals: leader proactivity, trust, and business-unit performance.

    Science.gov (United States)

    Crossley, Craig D; Cooper, Cecily D; Wernsing, Tara S

    2013-05-01

    Building on decades of research on the proactivity of individual performers, this study integrates research on goal setting and trust in leadership to examine manager proactivity and business unit sales performance in one of the largest sales organizations in the United States. Results of a moderated-mediation model suggest that proactive senior managers establish more challenging goals for their business units (N = 50), which in turn are associated with higher sales performance. We further found that employees' trust in the manager is a critical contingency variable that facilitates the relationship between challenging sales goals and subsequent sales performance. This research contributes to growing literatures on trust in leadership and proactivity by studying their joint effects at a district-unit level of analysis while identifying district managers' tendency to set challenging goals as a process variable that helps translate their proactivity into the collective performance of their units. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  1. Analytical solutions for evaluating the thermal performances of wet air cooling coils under both unit and non-unit Lewis Factors

    International Nuclear Information System (INIS)

    Xia Liang; Chan, M.Y.; Deng, S.M.; Xu, X.G.

    2010-01-01

    Analytical solutions for evaluating the thermal performances of both chilled water wet cooling coils and direct expansion (DX) wet cooling coils, respectively, under both unit and non-unit Lewis Factors are developed and reported in this paper. The analytical solution was validated by comparing its predictions with those from numerically solving the fundamental governing equations of heat and mass transfer taking place in a wet cooling coil. With the analytical solutions, the distributions of air temperature and humidity ratio along air flow direction in a wet cooling coil can be predicted, and the differences in the thermal performances of the cooling coils under both unit and non-unit Lewis Factors can be identified. The analytical solutions, on one hand, can be a low-cost replacement to numerically solving the fundamental heat and mass transfer governing equations, and on the other hand, is able to deal with evaluating thermal performance for wet air cooling coils operated under both unit and non-unit Lewis Factors.

  2. Radioactive Acid Digestion Test Unit (RADTU), 1980

    International Nuclear Information System (INIS)

    Allen, C.R.

    1980-01-01

    The Radioactive Acid Digestion Test Unit (RADTU) was constructed at the Hanford Site, Richland, WA to demonstrate application of the acid digestion process for treating combustible transuranic wastes and scrap materials. Using its original tray digester vessel, RADTU recently completed a six-month campaign of processing potentially contaminated non-glovebox wastes from a Hanford plutonium facility. During the campaign, 2100 kg of largely cellulosic wastes were processed at an average sustained processing rate of 3 kg/h (limited by the acid-waste contact and the water boiloff rate from the acid feeds). On-line operating efficiency was nearly 50%, averaged over 12 hours/day, for five days/week. After shutdown, a new annular high-rate digester was installed for testing that demonstrated a sustained capacity of 8 kg/h to 10 kg/h with greatly improved contact between the digestion acid and the waste. The new unit began processing low-level waste from Hanford's z-Plant during June 1980. Plutonium levels in the waste processed will be increased gradually as operating experience has been gained. Processing recoverable scrap is expected to begin in the last quarter of CY 1980

  3. Maximum likelihood unit rooting test in the presence GARCH: A new test with increased power

    OpenAIRE

    Cook , Steve

    2008-01-01

    Abstract The literature on testing the unit root hypothesis in the presence of GARCH errors is extended. A new test based upon the combination of local-to-unity detrending and joint maximum likelihood estimation of the autoregressive parameter and GARCH process is presented. The finite sample distribution of the test is derived under alternative decisions regarding the deterministic terms employed. Using Monte Carlo simulation, the newly proposed ML t-test is shown to exhibit incre...

  4. ATLAS RPC performance on a dedicated cosmic ray test-stand

    International Nuclear Information System (INIS)

    Liberti, B.; Aielli, G.; Camarri, P.; Cardarelli, R.; Corradi, M.; Di Ciaccio, A.; Di Stante, L.; Palummo, L.; Pastori, E.; Salamon, A.; Santonico, R.; Solfaroli, E.

    2008-01-01

    596 RPC chambers have been assembled in the ATLAS Muon Spectrometer, covering a 7300 m 2 sensitive area with 355.000 read out channels. 1116 RPC Units were produced and tested before integration and installation on the experiment [A. Aloisio et al., 'The trigger chambers of the ATLAS muon spectrometer: production and tests', Nuclear Instruments and Methods A535 (2004) 265-271]. 192 ATLAS RPCs, the Barrel Outer Large (BOL) units were tested in INFN Roma Tor Vergata test stand

  5. Operation of the radioactive acid digestion test unit

    International Nuclear Information System (INIS)

    Blasewitz, A.G.; Allen, C.R.; Lerch, R.E.; Ely, P.C.; Richardson, G.L.

    1980-01-01

    The Radioactive Acid Digestion Test Unit (RADTU) has been constructed at Hanford to demonstrate the application of the Acid Digestion Process for treating combustible transuranic wastes and scrap materials. The RADTU with its original tray digestion vessel has recently completed a six-month campaign processing potentially contaminated nonglovebox wastes from a Hanford plutonium facility. During this campaign, it processed 2100 kg of largely cellulosic wastes at an average sustained processing rate of 3 kg/h as limited by the water boiloff rate from the acid feeds. The on-line operating efficiency was nearly 50% on a twelve hour/day, five day/week basis. Following this campaign, a new annular high rate digester has been installed for testing. In preliminary tests with simulated wastes, the new digester demonstrated a sustained capacity of 10 kg/h with greatly improved intimacy of contact between the digestion acid and the waste. The new design also doubles the heat transfer surface, which with reduced heat loss area, is expected to provide at least three times the water boiloff rate of the previous tray digester design. Following shakedown testing with simulated and low-level wastes, the new unit will be used to process combustible plutonium scrap and waste from Hanford plutonium facilities for the purposes of volume reduction, plutonium recovery, and stabilization of the final waste form

  6. Fat Tail Model for Simulating Test Systems in Multiperiod Unit Commitment

    Directory of Open Access Journals (Sweden)

    J. A. Marmolejo

    2015-01-01

    Full Text Available This paper describes the use of Chambers-Mallows-Stuck method for simulating stable random variables in the generation of test systems for economic analysis in power systems. A study that focused on generating test electrical systems through fat tail model for unit commitment problem in electrical power systems is presented. Usually, the instances of test systems in Unit Commitment are generated using normal distribution, but in this work, simulations data are based on a new method. For simulating, we used three original systems to obtain the demand behavior and thermal production costs. The estimation of stable parameters for the simulation of stable random variables was based on three generally accepted methods: (a regression, (b quantiles, and (c maximum likelihood, choosing one that has the best fit of the tails of the distribution. Numerical results illustrate the applicability of the proposed method by solving several unit commitment problems.

  7. United States nuclear tests, July 1945 through September 1992

    Energy Technology Data Exchange (ETDEWEB)

    1994-12-01

    This document lists chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. Several tests conducted during Operation Dominic involved missile launches from Johnston Atoll. Several of these missile launches were aborted, resulting in the destruction of the missile and nuclear device either on the pad or in the air.

  8. Test Report of Special Form Qualification Testing for the ORNL U ZipCan

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Oscar A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-01

    This test report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by 10 CFR 71.75 (d)(1)(i), ISO 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469 (b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in ANSI N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in ASTM E 493. The determined standardized leak rates from the test and calculation for both test units met the requirements for special form certification.

  9. Stereotype Threat, Test Anxiety, and Mathematics Performance

    Science.gov (United States)

    Tempel, Tobias; Neumann, Roland

    2014-01-01

    We investigated the combined effects of stereotype threat and trait test anxiety on mathematics test performance. Stereotype threat and test anxiety interacted with each other in affecting performance. Trait test anxiety predicted performance only in a diagnostic condition that prevented stereotype threat by stereotype denial. A state measure of…

  10. Equipment performance and radiation protection status in X-ray fluoroscopy units in Sudan

    International Nuclear Information System (INIS)

    Ahmed, N. A.; Nayl, A. I.; Suliman, I. I.

    2012-01-01

    The number of fluoroscopy and fluoroscopically guided procedures has been substantially growing in developing countries at the same time advanced and sophisticated equipment are used in some hospitals. However, radiation protection requirements are not necessarily well adopted. In this study nine fluoroscopy X-ray units in Sudan were examined for compliance with international standards. The tests included: beam quality, entrance surface air kerma, image quality and radiation field measurements. Staff radiation protection tools such as lead aprons and eye glasses were also visually examined to find out whether international recommendations were fulfilled and to determine the level of staff awareness. The measured peak tube voltage deviation exceeded the recommended tolerance level in 30 % of the measurements. The results of patient doses measurements exceeded the recommended reference dose levels in 43 % of the measurements; however image quality and radiation field generally fulfilled the requirements for most units. The study revealed that a considerable number of fluoroscopy units were not performing according to the international standards and highlights the need of optimisation of radiation protection. (authors)

  11. Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the electrical performance of photovoltaic modules and arrays under natural or simulated sunlight using a calibrated reference cell. 1.1.1 These test methods allow a reference module to be used instead of a reference cell provided the reference module has been calibrated using these test methods against a calibrated reference cell. 1.2 Measurements under a variety of conditions are allowed; results are reported under a select set of reporting conditions (RC) to facilitate comparison of results. 1.3 These test methods apply only to nonconcentrator terrestrial modules and arrays. 1.4 The performance parameters determined by these test methods apply only at the time of the test, and imply no past or future performance level. 1.5 These test methods apply to photovoltaic modules and arrays that do not contain series-connected photovoltaic multijunction devices; such module and arrays should be tested according to Test Methods E 2236. 1.6 The values stated in SI units are to be re...

  12. Brayton-Cycle Power-Conversion Unit Tested With Ion Thruster

    Science.gov (United States)

    Hervol, David S.

    2005-01-01

    Nuclear electric propulsion has been identified as an enabling technology for future NASA space science missions, such as the Jupiter Icy Moons Orbiter (JIMO) now under study. An important element of the nuclear electric propulsion spacecraft is the power conversion system, which converts the reactor heat to electrical power for use by the ion propulsion system and other spacecraft loads. The electrical integration of the power converter and ion thruster represents a key technical challenge in making nuclear electric propulsion technology possible. This technical hurdle was addressed extensively on December 1, 2003, when a closed- Brayton-cycle power-conversion unit was tested with a gridded ion thruster at the NASA Glenn Research Center. The test demonstrated end-to-end power throughput and marked the first-ever coupling of a Brayton turbo alternator and a gridded ion thruster, both of which are candidates for use on JIMO-type missions. The testing was conducted at Glenn's Vacuum Facility 6, where the Brayton unit was installed in the 3-m-diameter vacuum test port and the ion thruster was installed in the 7.6-m-diameter main chamber.

  13. Testing of motor unit synchronization model for localized muscle fatigue.

    Science.gov (United States)

    Naik, Ganesh R; Kumar, Dinesh K; Yadav, Vivek; Wheeler, Katherine; Arjunan, Sridhar

    2009-01-01

    Spectral compression of surface electromyogram (sEMG) is associated with onset of localized muscle fatigue. The spectral compression has been explained based on motor unit synchronization theory. According to this theory, motor units are pseudo randomly excited during muscle contraction, and with the onset of muscle fatigue the recruitment pattern changes such that motor unit firings become more synchronized. While this is widely accepted, there is little experimental proof of this phenomenon. This paper has used source dependence measures developed in research related to independent component analysis (ICA) to test this theory.

  14. RCGVS design improvement and depressurization capability tests for Ulchin nuclear power plant units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Kang Sik; Seong, Ho Je; Jeong, Won Sang; Seo, Jong Tae; Lee, Sang Keun [Korea Power Engineering Company, Inc., Seoul (Korea, Republic of); Lim, Keun Hyo; Choi, Kwon Sik; Oh, Chul Sung [Korea Electric Power Cooperation, Taejon (Korea, Republic of)

    1999-12-31

    The Reactor Coolant Gas Vent System(RCGVS) design for Ulchin Nuclear Power Plant Units 3 and 4 (UCN 3 and 4) has been improved from the Yonggwang Nuclear Power Plant Units 3 and 4 (YGN 3 and 4) based on the evaluation results for depressurization capability tests performed at YGN 3 and 4. There has been a series of plant safety analyses for Natural Circulation Cooldown(NCC) event and thermo-dynamic analyses with RELAP5 code for the steam blowdown phenomena in order to optimize the orifice size of UCN 3 and 4 RCGVS. Based on these analyses results, the RCGVS orifics size for UCN 3 and 4 has been reduced to 9/32 inch from the 11/32 inch for YGN 3 and 4. The depressurization capability tests, which were performed at UCN 3 in order to verify the FSAR NCC analysis results, show that the RCGVS depressurization rates are being within the acceptable ranges. Therefore, it is concluded that the orificed flow path of UCN 3 and 4 RCGVS is adequately designed, and can provide the safety-grade depressurization capability required for a safe plant operation. 6 refs., 5 figs., 1 tab. (Author)

  15. RCGVS design improvement and depressurization capability tests for Ulchin nuclear power plant units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Kang Sik; Seong, Ho Je; Jeong, Won Sang; Seo, Jong Tae; Lee, Sang Keun [Korea Power Engineering Company, Inc., Seoul (Korea, Republic of); Lim, Keun Hyo; Choi, Kwon Sik; Oh, Chul Sung [Korea Electric Power Cooperation, Taejon (Korea, Republic of)

    1998-12-31

    The Reactor Coolant Gas Vent System(RCGVS) design for Ulchin Nuclear Power Plant Units 3 and 4 (UCN 3 and 4) has been improved from the Yonggwang Nuclear Power Plant Units 3 and 4 (YGN 3 and 4) based on the evaluation results for depressurization capability tests performed at YGN 3 and 4. There has been a series of plant safety analyses for Natural Circulation Cooldown(NCC) event and thermo-dynamic analyses with RELAP5 code for the steam blowdown phenomena in order to optimize the orifice size of UCN 3 and 4 RCGVS. Based on these analyses results, the RCGVS orifics size for UCN 3 and 4 has been reduced to 9/32 inch from the 11/32 inch for YGN 3 and 4. The depressurization capability tests, which were performed at UCN 3 in order to verify the FSAR NCC analysis results, show that the RCGVS depressurization rates are being within the acceptable ranges. Therefore, it is concluded that the orificed flow path of UCN 3 and 4 RCGVS is adequately designed, and can provide the safety-grade depressurization capability required for a safe plant operation. 6 refs., 5 figs., 1 tab. (Author)

  16. Restart Testing Program for piping following steam generator replacement at North Anna Unit 1

    International Nuclear Information System (INIS)

    Bain, R.A.; Bayer, R.K.

    1993-01-01

    In order to provide assurance that the effects of performing steam generator replacement (SGR) at North Anna unit 1 had no adverse impact on plant piping systems, a cold functional verification restart testing program was developed. This restart testing program was implemented in lieu of a hot functional testing program normally used during the initial startup of a nuclear plant. A review of North Anna plant-specific and generic U.S. Nuclear Regulatory Commission requirements for restart testing was performed to ensure that no mandatory hot functional testing was required. This was determined to be the case, and the development of a cold functional test program was initiated. The cold functional test had inherent advantages as compared to the hot functional testing, while still providing assurance of piping system adequacy. The advantages of the cold verification program included reducing risk to personnel from hot piping, increasing the accuracy of measurements with the improvement in work conditions, eliminating engineering activities during the heatup process, and being able to record measurements as construction work was completed allowing for rework or repair of components if required. To ensure the effectiveness of the cold verification program, a project procedure was generated to identify the personnel, equipment, and measurement requirements. An engineering calculation was issued to document the scope of the restart test program, and an additional calculation was developed to provide acceptance criteria for the critical commodity measurements

  17. Power cycling and ramp test in R-2 and Mihama Unit 2 for MHI PWR fuels

    International Nuclear Information System (INIS)

    Baba, T.; Takahashi, T.; Kubo, H.; Fujiwara, Y.; Kondo, Y.

    1983-01-01

    Up to the present time, Mitsubishi has manufactured approximately 3000 fuel assemblies for Japanese PWRs, of which performance in reactors is satisfactory under base load operation. For the forthcoming load following age in Japan, expected in mid eighties, Mitsubishi is performing various R and D programs, so that load following operation can be smoothly introduced with current good performance maintained. R and D programs consist of two phases. One is the verification and demonstration of power ramping and cycling capability of the current design fuels, and the other is the development of remedy fuels with more operational margin. This paper describes the recent results obtained for the former phase, especially for the following two programs: (1) Power cycling and ramp test in R-2; (2) Power ramp demonstration (PRD) in Mihama Unit 2 (PRD-1). PIE works for power cycling and ramp test rods have been almost completed. The second PRD will be performed early in 1983

  18. Systematic Unit Testing in a Read-eval-print Loop

    DEFF Research Database (Denmark)

    Nørmark, Kurt

    2010-01-01

    .  The process of collecting the expressions and their results imposes only little extra work on the programmer.  The use of the tool provides for creation of test repositories, and it is intended to catalyze a much more systematic approach to unit testing in a read-eval-print loop.  In the paper we also discuss...... how to use a test repository for other purposes than testing.  As a concrete contribution we show how to use test cases as examples in library interface documentation.  It is hypothesized---but not yet validated---that the tool will motivate the Lisp programmer to take the transition from casual...

  19. Analogue particle identifier and test unit for automatic measuring of errors

    International Nuclear Information System (INIS)

    Boden, A.; Lauch, J.

    1979-04-01

    A high accuracy analogue particle identifier is described. The unit is used for particle identification or data correction of experimental based errors in magnetic spectrometers. Signals which are proportional to the energy, the time-of-flight or the position of absorption of the particles are supplied to an analogue computation circuit (multifunction converter). Three computation functions are available for different applications. The output of the identifier produces correction signals or pulses whose amplitudes are proportional to the mass of the particles. Particle identification and data correction can be optimized by the adjustment of variable parameters. An automatic test unit has been developed for adjustment and routine checking of particle identifiers. The computation functions can be tested by this unit with an accuracy of 1%. (orig.) [de

  20. Importance Analysis of In-Service Testing Components for Ulchin Unit 3

    International Nuclear Information System (INIS)

    Dae-Il Kan; Kil-Yoo Kim; Jae-Joo Ha

    2002-01-01

    We performed an importance analysis of In-Service Testing (IST) components for Ulchin Unit 3 using the integrated evaluation method for categorizing component safety significance developed in this study. The importance analysis using the developed method is initiated by ranking the component importance using quantitative PSA information. The importance analysis of the IST components not modeled in the PSA is performed through the engineering judgment, based on the expertise of PSA, and the quantitative and qualitative information for the IST components. The PSA scope for importance analysis includes not only Level 1 and 2 internal PSA but also Level 1 external and shutdown/low power operation PSA. The importance analysis results of valves show that 167 (26.55%) of the 629 IST valves are HSSCs and 462 (73.45%) are LSSCs. Those of pumps also show that 28 (70%) of the 40 IST pumps are HSSCs and 12 (30%) are LSSCs. (authors)

  1. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    Science.gov (United States)

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  2. Critical values for unit root tests in seasonal time series

    NARCIS (Netherlands)

    Ph.H.B.F. Franses (Philip Hans); B. Hobijn (Bart)

    1997-01-01

    textabstractIn this paper, we present tables with critical values for a variety of tests for seasonal and non-seasonal unit roots in seasonal time series. We consider (extensions of) the Hylleberg et al. and Osborn et al. test procedures. These extensions concern time series with increasing seasonal

  3. Spent fuel metal storage cask performance testing and future spent fuel concrete module performance testing

    International Nuclear Information System (INIS)

    McKinnon, M.A.; Creer, J.M.

    1988-10-01

    REA-2023 Gesellshaft fur Nuklear Service (GNS) CASTOR-V/21, Transnuclear TN-24P, and Westinghouse MC-10 metal storage casks, have been performance tested under the guidance of the Pacific Northwest Laboratory to determine their thermal and shielding performance. The REA-2023 cask was tested under Department of Energy (DOE) sponsorship at General Electric's facilities in Morris, Illinois, using BWR spent fuel from the Cooper Reactor. The other three casks were tested under a cooperative agreement between Virginia Power Company and DOE at the Idaho National Engineering Laboratory (INEL) by EGandG Idaho, Inc., using intact spent PWR fuel from the Surry reactors. The Electric Power Research Institute (EPRI) made contributions to both programs. A summary of the various cask designs and the results of the performance tests is presented. The cask designs include: solid and liquid neutron shields; lead, steel, and nodular cast iron gamma shields; stainless steel, aluminum, and copper baskets; and borated materials for criticality control. 4 refs., 8 figs., 6 tabs

  4. Safety review on unit testing of safety system software of nuclear power plant

    International Nuclear Information System (INIS)

    Liu Le; Zhang Qi

    2013-01-01

    Software unit testing has an important place in the testing of safety system software of nuclear power plants, and in the wider scope of the verification and validation. It is a comprehensive, systematic process, and its documentation shall meet the related requirements. When reviewing software unit testing, attention should be paid to the coverage of software safety requirements, the coverage of software internal structure, and the independence of the work. (authors)

  5. Experimentally Evaluated Explosion Resistance and Performance of Destruction Unit in Multiple Detonation of Ammunition

    Directory of Open Access Journals (Sweden)

    P. A. Baskakov

    2016-01-01

    Full Text Available The paper presents results of development and experimental investigation of explosion resistance and destruction unit performance in multiple detonation of ammunition with an explosive weight up to 0.7 kg of TNT. A preliminary evaluation of the explosion resistance was carried out using a model of explosion resistance localizer, represented as a thick-walled tube. As a result of explosive tests, the nature and characteristics of tube deformation under repeated explosions have been revealed. The findings allowed us to develop the first embodiment of the destruction unit with a turning non-separable heater and a two-layer localizer, which was heated by the induction field. The explosive life tests have revealed the following drawbacks: low resource localizer, jamming rotating mechanism in contact with the splinters, and impossible replacement of damaged localizer. In the second embodiment of the destruction unit a plate-assembled easychange localizer is mounted on the heater, and it is heated by heat transfer from the core. Tests have shown that, with such a placement, the uniform heating of the localizer is not reached. This leads to incomplete destruction of ammunition. Besides, because of the low strength of the pins connecting the plates, occurrs their rapid destruction. Taking into consideration the shortcomings of the previous two designs, the third option of the destruction unit with a replaceable localizer and induction heating of a localizer has been designed. A localizer material having high mechanical strength at high temperatures and good ferromagnetic properties has been selected. The paper offers an all-metal localizer design with the thickest wall at the bottom that is the most damageable. The paper has experimentally determined a critical deformation of the localizer when destroying the ammunition with varying weight of explosive and defined the heater and bump resource. As a result, the work proposes the destruction unit design

  6. Testing and Results of Vacuum Swing Adsorption Units for Spacesuit Carbon Dioxide and Humidity Control

    Science.gov (United States)

    McMillin, Summer D.; Broerman, Craig D.; Swickrath, Michael; Anderson, Molly

    2011-01-01

    A principal concern for extravehicular activity (EVA) spacesuits is the capability to control carbon dioxide (CO2) and humidity (H2O) for the crewmember. The release of CO2 in a confined or unventilated area is dangerous for human health and leads to asphyxiation; therefore, CO2 and H2O control become leading factors in the design and development of the spacesuit. An amine-based CO2 and H2O vapor sorbent for use in pressure-swing regenerable beds has been developed by Hamilton Sundstrand. The application of solidamine materials with vacuum swing adsorption technology has shown the capacity to concurrently manage CO2 and H2O levels through a fully regenerative cycle eliminating mission constraints imposed with nonregenerative technologies. Two prototype solid amine-based systems, known as rapid cycle amine (RCA), were designed to continuously remove CO2 and H2O vapor from a flowing ventilation stream through the use of a two-bed amine based, vacuum-swing adsorption system. The Engineering and Science Contract Group (ESCG) RCA implements radial flow paths, whereas the Hamilton Sundstrand RCA was designed with linear flow paths. Testing was performed in a sea-level pressure environment and a reduced-pressure environment with simulated human metabolic loads in a closed-loop configuration. This paper presents the experimental results of laboratory testing for a full-size and a sub-scale test article. The testing described here characterized and evaluated the performance of each RCA unit at the required Portable Life Support Subsystem (PLSS) operating conditions. The test points simulated a range of crewmember metabolic rates. The experimental results demonstrated the ability of each RCA unit to sufficiently remove CO2 and H2O from a closed loop ambient or sub-ambient atmosphere.

  7. Performance of a system with full- and pilot-scale sludge drying reed bed units treating septic tank sludge in Brazil.

    Science.gov (United States)

    Calderón-Vallejo, Luisa Fernanda; Andrade, Cynthia Franco; Manjate, Elias Sete; Madera-Parra, Carlos Arturo; von Sperling, Marcos

    2015-01-01

    This study investigated the performance of sludge drying reed beds (SDRB) at full- and pilot-scale treating sludge from septic tanks in the city of Belo Horizonte, Brazil. The treatment units, planted with Cynodon spp., were based on an adaptation of the first-stage of the French vertical-flow constructed wetland, originally developed for treating sewage. Two different operational phases were investigated; in the first one, the full-scale unit was used together with six pilot-scale columns in order to test different feeding strategies. For the second phase, only the full-scale unit was used, including a recirculation of the filtered effluent (percolate) to one of the units of the French vertical wetland. Sludge application was done once a week emptying a full truck, during 25 weeks. The sludge was predominantly diluted, leading to low solids loading rates (median values of 18 kgTS m(-2) year(-1)). Chemical oxygen demand removal efficiency in the full-scale unit was reasonable (median of 71%), but the total solids removal was only moderate (median of 44%) in the full-scale unit without recirculation. Recirculation did not bring substantial improvements in the overall performance. The other loading conditions implemented in the pilot columns also did not show statistically different performances.

  8. An analysis of unit tests of a flight software product line

    NARCIS (Netherlands)

    Ganesan, D.; Lindvall, M.; McComas, D.; Bartholomew, M.; Slegel, S.; Medina, B.; Krikhaar, R.; Verhoef, C.; Dharmalingam, G.; Montgomery, L.P.

    2013-01-01

    This paper presents an analysis of the unit testing approach developed and used by the Core Flight Software System (CFS) product line team at the NASA Goddard Space Flight Center (GSFC). The goal of the analysis is to understand, review, and recommend strategies for improving the CFS' existing unit

  9. Soil washing physical separations test procedure - 300-FF-1 operable unit

    Energy Technology Data Exchange (ETDEWEB)

    Belden, R.D.

    1993-10-08

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The {open_quotes}Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,{close_quotes} Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the {open_quotes}300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,{close_quotes} (DOE-RL 1993).

  10. Soil washing physical separations test procedure - 300-FF-1 operable unit

    International Nuclear Information System (INIS)

    Belden, R.D.

    1993-01-01

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The open-quotes Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,close quotes Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the open-quotes 300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,close quotes (DOE-RL 1993)

  11. Assessment Of Nurses Performance During Cardiopulmonary Resuscitation In Intensive Care Unit And Cardiac Care Unit At The Alexandria Main University Hospital.

    Directory of Open Access Journals (Sweden)

    Dr. Nagla Hamdi Kamal Khalil El- Meanawi

    2015-08-01

    Full Text Available Abstract Background Cardiopulmonary resuscitation one of the most emergency management the nurse has a pivotal role and should be highly qualified in performing these procedures. The aim of the study is to assess performance of nurses during Cardio pulmonary resuscitation for patient with cardiac arrest In Intensive Care Unit and Cardiac Care Unit at the Alexandria main university hospital. To answer the question what are the most common area of satisfactory and area of neglection in nurses performance during Cardio Pulmonary Resuscitation. The sample consists of 53 staff nurses working in Intensive care unit amp cardiac care unit at Alexandria main university hospital. The tools of data collection were structured of questionnaire sheet and observational cheek list. The results showed that unsatisfactory performance between nurses in both units. The study concluded that all nurses need to improve their performance during cardiopulmonary resuscitation for patient with cardiac arrest it is crucial for nursing staff to participate in CPR courses in order to refresh and update their theoretical knowledge and performance skills and consequently to improve the safety and effectiveness of care. The study recommended that continuous evaluation of nurses knowledge and performance is essential the optimal frequency with which CPR training should be implemented at least every 6 months in order to avoid deterioration in nurses CPR knowledge and skills.

  12. Performance Characterization and Simulation of Amine-Based Vacuum Swing Sorption Units for Spacesuit Carbon Dioxide and Humidity Control

    Science.gov (United States)

    Swickrath, Michael J.; Watts, Carly; Anderson, Molly; McMillin, Summer; Broerman, Craig; Colunga, Aaron; Vogel, Matthew

    2012-01-01

    Controlling carbon dioxide (CO2) and water (H2O) vapor concentrations in a space suit is critical to ensuring an astronauts safety, comfort, and capability to perform extra-vehicular activity (EVA) tasks. Historically, this has been accomplished using lithium hydroxide (LiOH) and metal oxide (MetOx) canisters. Lithium hydroxide is a consumable material that requires priming with water before it becomes effective at removing carbon dioxide. MetOx is regenerable through a power-intensive thermal cycle but is significantly heavier on a volume basis than LiOH. As an alternative, amine-based vacuum swing beds are under aggressive development for EVA applications. The vacuum swing units control atmospheric concentrations of both CO2 and H2O through fully-regenerative process. The current concept, referred to as the rapid cycle amine (RCA), has resulted in numerous laboratory prototypes. Performance of these prototypes have been assessed experimentally and documented in previous reports. To support developmental e orts, a first principles model has also been established for the vacuum swing sorption technology. For the first time in several decades, a major re-design of Portable Life Support System (PLSS) for the extra-vehicular mobility unit (EMU) is underway. NASA at Johnson Space Center built and tested an integrated PLSS test bed of all subsystems under a variety of simulated EVA conditions of which the RCA prototype played a significant role. The efforts documented herein summarize RCA test performance and simulation results for single and variable metabolic rate experiments in an integrated context. In addition, a variety of off-nominal tests were performed to assess the capability of the RCA to function under challenging circumstances. Tests included high water production experiments, degraded vacuum regeneration, and deliberate valve/power failure and recovery.

  13. Examining the Islamic stock market efficiency: Evidence from nonlinear ESTAR unit root tests

    Directory of Open Access Journals (Sweden)

    Rahmat Heru Setianto

    2015-04-01

    Full Text Available This paper empirically examines the efficient market hypothesis (EMH in the Islamic stock market namely Jakarta Islamic Index by emphasizing on the random walk behavior and nonlinearity. In the first step, we employ Brock et al. (1996 test to examine the presence of nonlinear behavior in Jakarta Islamic Index. The evidence of nonlinear behavior in the indices, motivate us to use nonlinear ESTAR unit root test procedure recently developed by Kapetanios et al. (2003 and Kruse (2011. The nonlinear unit root test procedure fail to rejects the null hypothesis of unit root for the indices, suggesting that Jakarta Islamic Index characterized by random walk process supporting the theory of efficient market hypothesis. In addition, Lumsdaine and Papel (LP test identified significant structural breaks in the index series.

  14. Unit Root Testing and Estimation in Nonlinear ESTAR Models with Normal and Non-Normal Errors.

    Directory of Open Access Journals (Sweden)

    Umair Khalil

    Full Text Available Exponential Smooth Transition Autoregressive (ESTAR models can capture non-linear adjustment of the deviations from equilibrium conditions which may explain the economic behavior of many variables that appear non stationary from a linear viewpoint. Many researchers employ the Kapetanios test which has a unit root as the null and a stationary nonlinear model as the alternative. However this test statistics is based on the assumption of normally distributed errors in the DGP. Cook has analyzed the size of the nonlinear unit root of this test in the presence of heavy-tailed innovation process and obtained the critical values for both finite variance and infinite variance cases. However the test statistics of Cook are oversized. It has been found by researchers that using conventional tests is dangerous though the best performance among these is a HCCME. The over sizing for LM tests can be reduced by employing fixed design wild bootstrap remedies which provide a valuable alternative to the conventional tests. In this paper the size of the Kapetanios test statistic employing hetroscedastic consistent covariance matrices has been derived and the results are reported for various sample sizes in which size distortion is reduced. The properties for estimates of ESTAR models have been investigated when errors are assumed non-normal. We compare the results obtained through the fitting of nonlinear least square with that of the quantile regression fitting in the presence of outliers and the error distribution was considered to be from t-distribution for various sample sizes.

  15. 10 CFR 26.168 - Blind performance testing.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Blind performance testing. 26.168 Section 26.168 Energy... and Human Services § 26.168 Blind performance testing. (a) Each licensee and other entity shall submit blind performance test samples to the HHS-certified laboratory. (1) During the initial 90-day period of...

  16. Motor unit firing frequency of lower limb muscles during an incremental slide board skating test.

    Science.gov (United States)

    Piucco, Tatiane; Bini, Rodrigo; Sakaguchi, Masanori; Diefenthaeler, Fernando; Stefanyshyn, Darren

    2017-11-01

    This study investigated how the combination of workload and fatigue affected the frequency components of muscle activation and possible recruitment priority of motor units during skating to exhaustion. Ten male competitive speed skaters performed an incremental maximal test on a slide board. Activation of six muscles from the right leg was recorded throughout the test. A time-frequency analysis was performed to compute overall, high, and low frequency bands from the whole signal at 10, 40, 70, and 90% of total test time. Overall activation increased for all muscles throughout the test (p  0.80). There was an increase in low frequency (90 vs. 10%, p = 0.035, ES = 1.06) and a decrease in high frequency (90 vs. 10%, p = 0.009, ES = 1.38, and 90 vs. 40%, p = 0.025, ES = 1.12) components of gluteus maximus. Strong correlations were found between the maximal cadence and vastus lateralis, gluteus maximus and gluteus medius activation at the end of the test. In conclusion, the incremental skating test lead to an increase in activation of lower limb muscles, but only gluteus maximus was sensitive to changes in frequency components, probably caused by a pronounced fatigue.

  17. Stand tests of the grader unit AKD-2

    Energy Technology Data Exchange (ETDEWEB)

    Kocheskhov, S.M.; Bagley, A.V.; Shalkov, A.V.

    1982-01-01

    Results are presented of stand tests of a static operating grader designed for unmanned extraction of deep beds with programmed control of the unit AKD-2 according to hypsometry of the seam occurrence. Malfunctions in a number of grader assemblies are revealed and eliminated. Parameters are defined which characterize the kinematics and dynamics of the grader mechanism.

  18. Is Malaysian Stock Market Efficient? Evidence from Threshold Unit Root Tests

    OpenAIRE

    Qaiser Munir; Kasim Mansur

    2009-01-01

    This paper investigates the behavior of Kuala Lumpur Stock Exchange Composite Index (KLCI) for the period from 1980:1 to 2008:8 using a two-regime threshold autoregressive (TAR) model with an autoregressive unit root developed by Caner and Hansen [Threshold autoregression with a unit roots, Econometrics 69 (6) (2001) 1555-1596] which allows testing nonlinearity and nonstationarity simultaneously. Our finding indicates that the KLCI is a nonlinear series that is characterized by a unit root pr...

  19. Theoretical parameter histories of dynamic tests during power commissioning of Mochovce units power level up to 100 % Nnom

    International Nuclear Information System (INIS)

    Jagrik, J.; Mraz, M.; Rapant, M.; Stefanovic, P.; Kotasek, J.; Gieci, A.; Macko, J.; Mosny, J.

    1998-01-01

    Theoretical histories of selected parameters for dynamic tests carried out in the course of power commissioning of the Mochovce Unit 1 at the power level 100% N nom are shown in the report. The expected histories given were developed based on calculations performed by means of simulator in Nuclear Power Plants Research Institute Trnava, Inc., simulator in EGU Praha and simulator at the Mochovce plant, as well as based on similar tests at both Bohunice and Dukovany plants

  20. Application tests of a new-type LNG rapid gasification unit

    Directory of Open Access Journals (Sweden)

    Ping Yan

    2017-01-01

    Full Text Available Liquefied natural gas (LNG is stored under low temperature and high pressure. It has to be gasified before it is used. Therefore, LNG gasification unit is essential and it is vital to the high-efficiency utilization of LNG. In this paper, a new-type LNG rapid gasification unit was developed. Adopted in this unit are some innovative technologies authorized with the national patent of invention, such as the umbrella-shape gas flow circle unit, the flue gas circulation system and the water feeding system, which help to guarantee its operation safety and increase its operation efficiency. After it was justified in lab test, the unit for industrial application was designed and manufactured and then tested to verify its design rationality. The results show that the new-type LNG rapid gasification unit meets the design requirements in the aspect of efficiency, exhaust gas loss, radiation loss and fuel gas consumption rate; at a load of 1800–2200 m3/h, its efficiency is over 95%; at a load of 1976.0 m3/h which is close to the design value of 2000 m3/h, its efficiency is 96.34% or even up to 2800 m3/h. This new-type LNG rapid gasification unit is adaptable to a large range of loads and can adapt to the rapid increase of external load. Its fuel gas consumption rate is only 1.5%, which is in the range of energy conservation. It presents the advantages of high heating efficiency, rapid startup, high gasification rate, compact structure, small land occupation and invulnerability to the environment, therefore, it is applicable to the middle and small independent regions which cannot be connected to the natural gas supply pipeline networks due to various reasons.

  1. The Road Side Unit for the A270 Test Site

    NARCIS (Netherlands)

    Passchier, I.; Driessen, B.J.F.; Heijligers, B.M.R.; Netten, B.D.; Schackmann, P.P.M.

    2011-01-01

    The design and implementation of the Road Side Unit for the A270 Test Site is presented. It consists of a sensor platform and V2I communication platform with full coverage of the test site. A service platform enables applications to make use of these facilities. The RSU will be used both for the

  2. On the stability of the unit root test | Atil | Afrika Statistika

    African Journals Online (AJOL)

    Abstract. We propose to study, by two different approaches, Bayesian and classical, the test of the hypothesis of stationary first order autoregressive model against the random walk model. Therefore, we are going to present the classical approach and the Bayesian approach of this test says the unit root test. The principal ...

  3. State of malaria diagnostic testing at clinical laboratories in the United States, 2010: a nationwide survey

    Directory of Open Access Journals (Sweden)

    Abanyie Francisca A

    2011-11-01

    Full Text Available Abstract Background The diagnosis of malaria can be difficult in non-endemic areas, such as the United States, and delays in diagnosis and errors in treatment occur too often. Methods A nationwide survey of laboratories in the United States and its nine dependent territories was conducted in 2010 to determine factors that may contribute to shortcomings in the diagnosis of malaria. This survey explored the availability of malaria diagnostic tests, techniques used, and reporting practices. Results The survey was completed by 201 participants. Ninety percent reported that their laboratories had at least one type of malaria diagnostic test available on-site. Nearly all of the respondents' laboratories performed thick and thin smears on-site; approximately 50% had access to molecular testing; and only 17% had access to rapid diagnostic tests on-site. Seventy-three percent reported fewer than five confirmed cases of malaria in their laboratory during the 12-month period preceding the survey. Twenty-eight percent stated that results of species identification took more than 24 hours to report. Only five of 149 respondents that performed testing 24 hours a day, 7 days a week complied with all of the Clinical and Laboratory Standards Institute (CLSI guidelines for analysis and reporting of results. Conclusion Although malaria diagnostic testing services were available to a majority of U.S. laboratories surveyed, very few were in complete compliance with all of the CLSI guidelines for analysis and reporting of results, and most respondents reported very few cases of malaria annually. Laboratories' difficulty in adhering to the rigorous CLSI guidelines and their personnel's lack of practice and proficiency may account for delays and errors in diagnosis. It is recommended that laboratories that infrequently process samples for malaria seek opportunities for practice and proficiency training annually and take advantage of available resources to assist in

  4. Performance Testing of Cutting Fluids

    DEFF Research Database (Denmark)

    Belluco, Walter

    The importance of cutting fluid performance testing has increased with documentation requirements of new cutting fluid formulations based on more sustainable products, as well as cutting with minimum quantity of lubrication and dry cutting. Two sub-problems have to be solved: i) which machining...... tests feature repeatability, reproducibility and sensitivity to cutting fluids, and ii) to what extent results of one test ensure relevance to a wider set of machining situations. The present work is aimed at assessing the range of validity of the different testing methods, investigating correlation...... within the whole range of operations, materials, cutting fluids, operating conditions, etc. Cutting fluid performance was evaluated in turning, drilling, reaming and tapping, and with respect to tool life, cutting forces, chip formation and product quality (dimensional accuracy and surface integrity...

  5. Performance of diagnostic mammography differs in the United States and Denmark

    DEFF Research Database (Denmark)

    Jensen, Allan; Geller, Berta M; Gard, Charlotte C

    2010-01-01

    in the United States and Denmark. The performance of 93,585 diagnostic mammograms from 180 facilities contributing data to the US Breast Cancer Surveillance Consortium (BCSC) from 1999 to 2001 was compared to that of all 51,313 diagnostic mammograms performed at Danish clinics in 2000. We used the imaging...... workup's final assessment to determine sensitivity, specificity and an estimate of accuracy: area under the receiver-operating characteristics (ROCs) curve (AUC). Diagnostic mammography had slightly higher sensitivity in the United States (85%) than in Denmark (82%). In contrast, it had higher...... specificity in Denmark (99%) than in the United States (93%). The AUC was high in both countries: 0.91 in United States and 0.95 in Denmark. Denmark's higher accuracy may result from supplementary ultrasound examinations, which are provided to 74% of Danish women but only 37% to 52% of US women. In addition...

  6. Development of performance analysis support modules in Younggwang NPP unit 3 and 4

    International Nuclear Information System (INIS)

    Heo, G. Y.; Lee, S. J.; Jang, S. H.; Choi, S. S.; Choi, Q. H.; Gee, M. H.; Heo, I.

    2003-01-01

    This paper covers the unmeasured parameter estimation module, the performance degradation estimation module, and the performance degradation diagnosis module that are the supporting modules of the thermal performance analysis program of Younggwang nuclear power plant unit 3 and 4, PERUPS (PERformance UPgrade System), which was developed by KHNP, KEPRI, Hoseo university, and ACT. The unmeasured parameter estimation module plays a role in the generation of estimated values for the parameters that are necessary but there are no sensors. The performance degradation estimation module shows the impact for electric gain and loss according to the parameters related to turbine cycle performance. The performance degradation diagnosis module provides the belief according degradation causes considering the measurement uncertainty, analysis uncertainty, and correlation among parameters. Reference data for the development of each module was prepared by a turbine cycle simulation tool, PEPSE. The unmeasured parameter estimation module and the performance degradation estimation module make the estimation correlations by the regression analysis using the reference data. In the performance degradation diagnosis module, Bayesian network is used for the modeling of uncertainty and knowledge-base. The validation of the developed modules was performed by the test data generated by PEPSE, and accomplished by the actual data again

  7. Optimization Solutions for Improving the Performance of the Parallel Reduction Algorithm Using Graphics Processing Units

    Directory of Open Access Journals (Sweden)

    Ion LUNGU

    2012-01-01

    Full Text Available In this paper, we research, analyze and develop optimization solutions for the parallel reduction function using graphics processing units (GPUs that implement the Compute Unified Device Architecture (CUDA, a modern and novel approach for improving the software performance of data processing applications and algorithms. Many of these applications and algorithms make use of the reduction function in their computational steps. After having designed the function and its algorithmic steps in CUDA, we have progressively developed and implemented optimization solutions for the reduction function. In order to confirm, test and evaluate the solutions' efficiency, we have developed a custom tailored benchmark suite. We have analyzed the obtained experimental results regarding: the comparison of the execution time and bandwidth when using graphic processing units covering the main CUDA architectures (Tesla GT200, Fermi GF100, Kepler GK104 and a central processing unit; the data type influence; the binary operator's influence.

  8. PERFORMANCE OF ISLAMIC UNIT TRUSTS DURING THE 2007 GLOBAL FINANCIAL CRISIS: EVIDENCE FROM MALAYSIA

    Directory of Open Access Journals (Sweden)

    Salina H. Kassim

    2012-01-01

    Full Text Available By focusing on the Malaysian Islamic unit trusts over the period of January 2000 to December 2009, this study attempts to analyse the performance of the Islamic unit trusts in various economic conditions; during a crisis period and non-crisis period. The adjusted Sharpe index, adjusted Jensen Alpha index, and Treynor index are adopted to compare the performance of the Islamic unit trusts against the market benchmark and risk-free return. In measuring risk and diversification, the study relies on the standard deviation and R2 coefficient of determination, respectively. The findings reveal that during the non-crisis period, the performance of the Islamic unit trusts is comparable to that of the market benchmark, while during the crisis period, the Islamic unit trusts perform better compared to the non-crisis period. These findings suggests that the Islamic unit trust funds can be an ideal hedging instrument during a down market and provide potential portfolio diversification benefits for the investors. Based on these findings, the investors could strategize and diversify their portfolio accordingly during different market conditions.

  9. Calculation method for the seasonal performance of heat pump compact units and validation. Appendix

    Energy Technology Data Exchange (ETDEWEB)

    Wemhoener, C.; Dott, R.; Afjei, Th. [University of Applied Sciences Northwestern Switzerland, Institute of Energy in Buildings, Muttenz (Switzerland); Huber, H.; Helfenfinger, D.; Keller, P.; Furter, R. [University of Applied Sciences Lucerne (HTA), Test center HLKS, Horw (Switzerland)

    2007-02-15

    This appendix to a comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of tests made on compact heat pump units that have been developed for the heating of low energy consumption houses built to MINERGIE or MINERGIE-P standards. The tests on these units, which combine the functions of space heating, domestic hot water preparation and ventilation in one unit are presented and discussed. Test conditions are described; these cover ventilation, acoustic, hygiene and safety aspects. Detailed results from the two test objects - buildings built to MINERGIE and MINERGIE-P low energy consumption standards - are presented and discussed. The calculation methods used are examined and discussed.

  10. Brayton Power Conversion Unit Tested: Provides a Path to Future High-Power Electric Propulsion Missions

    Science.gov (United States)

    Mason, Lee S.

    2003-01-01

    Closed-Brayton-cycle conversion technology has been identified as an excellent candidate for nuclear electric propulsion (NEP) power conversion systems. Advantages include high efficiency, long life, and high power density for power levels from about 10 kWe to 1 MWe, and beyond. An additional benefit for Brayton is the potential for the alternator to deliver very high voltage as required by the electric thrusters, minimizing the mass and power losses associated with the power management and distribution (PMAD). To accelerate Brayton technology development for NEP, the NASA Glenn Research Center is developing a low-power NEP power systems testbed that utilizes an existing 2- kWe Brayton power conversion unit (PCU) from previous solar dynamic technology efforts. The PCU includes a turboalternator, a recuperator, and a gas cooler connected by gas ducts. The rotating assembly is supported by gas foil bearings and consists of a turbine, a compressor, a thrust rotor, and an alternator on a single shaft. The alternator produces alternating-current power that is rectified to 120-V direct-current power by the PMAD unit. The NEP power systems testbed will be utilized to conduct future investigations of operational control methods, high-voltage PMAD, electric thruster interactions, and advanced heat rejection techniques. The PCU was tested in Glenn s Vacuum Facility 6. The Brayton PCU was modified from its original solar dynamic configuration by the removal of the heat receiver and retrofitting of the electrical resistance gas heater to simulate the thermal input of a steady-state nuclear source. Then, the Brayton PCU was installed in the 3-m test port of Vacuum Facility 6, as shown. A series of tests were performed between June and August of 2002 that resulted in a total PCU operational time of about 24 hr. An initial test sequence on June 17 determined that the reconfigured unit was fully operational. Ensuing tests provided the operational data needed to characterize PCU

  11. Nuclear code case development of printed-circuit heat exchangers with thermal and mechanical performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Aakre, Shaun R. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Mechanical Engineering; Jentz, Ian W. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Mechanical Engineering; Anderson, Mark H. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Mechanical Engineering

    2018-03-27

    The U.S. Department of Energy has agreed to fund a three-year integrated research project to close technical gaps involved with compact heat exchangers to be used in nuclear applications. This paper introduces the goals of the project, the research institutions, and industrial partners working in collaboration to develop a draft Boiler and Pressure Vessel Code Case for this technology. Heat exchanger testing, as well as non-destructive and destructive evaluation, will be performed by researchers across the country to understand the performance of compact heat exchangers. Testing will be performed using coolants and conditions proposed for Gen IV Reactor designs. Preliminary observations of the mechanical failure mechanisms of the heat exchangers using destructive and non-destructive methods is presented. Unit-cell finite element models assembled to help predict the mechanical behavior of these high-temperature components are discussed as well. Performance testing methodology is laid out in this paper along with preliminary modeling results, an introduction to x-ray and neutron inspection techniques, and results from a recent pressurization test of a printed-circuit heat exchanger. The operational and quality assurance knowledge gained from these models and validation tests will be useful to developers of supercritical CO2 systems, which commonly employ printed-circuit heat exchangers.

  12. Housekeeping Closure Report for Corrective Action Unit 119: Storage Tanks, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    2000-01-01

    The Federal Facility Agreement and Consent Order was entered into by the State of Nevada, US Department of Energy, and US Department of Defense to identify sites of potential historical contamination and implement corrective actions based on public health and environmental considerations. The facilities subject to this agreement include the Nevada Test Site (NTS), parts of the Tonopah Test Range, parts to the Nellis Air Force Range, the Central Nevada Test Area, and the Project Shoal Area. Corrective Action Sites (CASs) are areas potentially requiring corrective actions and may include solid waste management units, individual disposal, or release sites. Based on geography, technical similarity, agency responsibility, or other appropriate reasons, CASs are grouped together into Corrective Action Units (CAUs) for the purpose of determining appropriate corrective actions. This report contains the Closure Verification Forms for cleanup activities that were performed at 19 CASs with in CAU 119 on the NTS. The form for each CAS provides the location, directions to the site, general description, and photographs of the site before and after cleanup activities. Activities included verification of the prior removal of both aboveground and underground gas/oil storage tanks, gas sampling tanks, pressure fuel tanks, tank stands, trailers, debris, and other material. Based on these former activities, no further action is required at these CASs

  13. Convergence Hypothesis: Evidence from Panel Unit Root Test with Spatial Dependence

    Directory of Open Access Journals (Sweden)

    Lezheng Liu

    2006-10-01

    Full Text Available In this paper we test the convergence hypothesis by using a revised 4- step procedure of panel unit root test suggested by Evans and Karras (1996. We use data on output for 24 OECD countries over 40 years long. Whether the convergence, if any, is conditional or absolute is also examined. According to a proposition by Baltagi, Bresson, and Pirotte (2005, we incorporate spatial autoregressive error into a fixedeffect panel model to account for not only the heterogeneous panel structure, but also spatial dependence, which might induce lower statistical power of conventional panel unit root test. Our empirical results indicate that output is converging among OECD countries. However, convergence is characterized as conditional. The results also report a relatively lower convergent speed compared to conventional panel studies.

  14. Nuclear material control and accountancy planning and performance testing

    International Nuclear Information System (INIS)

    Mike Enhinger; Dennis Wilkey; Rod Martin; Ken Byers; Brian Smith

    1999-01-01

    An overview of performance testing as used at U.S. Department of Energy facilities is provided. Performance tests are performed on specific aspects of the regulations or site policy. The key issues in establishing a performance testing program are: identifying what needs to be tested; determining how to test; establishing criteria to evaluate test results. The program elements of performance testing program consist of: planning; coordination; conduct; evaluation. A performance test may be conducted of personnel or equipment. The DOE orders for nuclear material control and accountancy are divided into three functional areas: program administration, material accounting, and material control. Examples performance tests may be conducted on program administration, accounting, measurement and measurement control, inventory, and containment [ru

  15. Testing of an Annular Linear Induction Pump for the Fission Surface Power Technology Demonstration Unit

    Science.gov (United States)

    Polzin, K. A.; Pearson, J. B.; Webster, K.; Godfoy, T. J.; Bossard, J. A.

    2013-01-01

    Results of performance testing of an annular linear induction pump that has been designed for integration into a fission surface power technology demonstration unit are presented. The pump electromagnetically pushes liquid metal (NaK) through a specially-designed apparatus that permits quantification of pump performance over a range of operating conditions. Testing was conducted for frequencies of 40, 55, and 70 Hz, liquid metal temperatures of 125, 325, and 525 C, and input voltages from 30 to 120 V. Pump performance spanned a range of flow rates from roughly 0.3 to 3.1 L/s (4.8 to 49 gpm), and pressure heads of <1 to 104 kPa (<0.15 to 15 psi). The maximum efficiency measured during testing was 5.4%. At the technology demonstration unit operating temperature of 525 C the pump operated over a narrower envelope, with flow rates from 0.3 to 2.75 L/s (4.8 to 43.6 gpm), developed pressure heads from <1 to 55 kPa (<0.15 to 8 psi), and a maximum efficiency of 3.5%. The pump was supplied with three-phase power at 40 and 55 Hz using a variable-frequency motor drive, while power at 55 and 70 Hz was supplied using a variable-frequency power supply. Measured performance of the pump at 55 Hz using either supply exhibited good quantitative agreement. For a given temperature, the peak in efficiency occurred at different flow rates as the frequency was changed, but the maximum value of efficiency was relative insensitive within 0.3% over the frequency range tested, including a scan from 45 to 78 Hz. The objectives of the FSP technology project are as follows:5 • Develop FSP concepts that meet expected surface power requirements at reasonable cost with added benefits over other options. • Establish a nonnuclear hardware-based technical foundation for FSP design concepts to reduce overall development risk. • Reduce the cost uncertainties for FSP and establish greater credibility for flight system cost estimates. • Generate the key nonnuclear products to allow Agency

  16. TID Environmental Performance Testing In Support of the Mayak Fissile Material Storage Facility

    International Nuclear Information System (INIS)

    Tanner, Jennifer E.; Undem, Halvor A.; Roberts, Bruce A.; Griggs, James R.; Pratt, Sharon L.; Smith, Matthew H.

    2001-01-01

    The purpose of the test and evaluation of tamper indicating devices (TIDs) described in this report is to assure that the recommended TID technologies are acceptable for use at the Mayak FMSF. TID acceptance is based on TID performance with respect to mutually agreed functional, operational, and security requirements for the FMSF, taking into account both the United States and the Russian Federation views. Although some Russian views have been documented, very little information at the level required for formal test planning had been received prior to the start of the testing campaign. Consequently, this report currently represents US recommendations for an arms control and/or safeguards and security application. Acceptance of these test results and recommendations by those Russian Federation entities responsible for the Mayak FMSF will be required before implementing any TID regime at Mayak FMSF

  17. Experimental studies on improvement of coefficient of performance of window air conditioning unit

    Directory of Open Access Journals (Sweden)

    Tharves Mohideen Sheik Ismail

    2017-01-01

    Full Text Available This paper presents the performance analysis of a window air conditioner unit incorporated with wick less loop heat pipes (WLHP. The WLHP are located on the evaporator side of the air conditioning unit. The working medium for the WLHP is R134a refrigerant gas, an alternate refrigerant. The supply and return humidity of room air, the heat removal rat, and the coefficient of performance of the unit are analyzed for various ambient and room temperatures before and after incorporation of WLHP. The performance curves are drawn by comparing the power consumption and humidity collection rates for various room and ambient temperatures. The results show that coefficient of performance of the unit is improved by 18% to 20% after incorporation of WLHP due to pre-cooling of return air by WLHP, which reduces the thermal load on compressor. Similarly, the energy consumption is reduced by 20% to 25% due to higher thermostat setting and the humidity collection is improved by 35% due to pre-cooling effect of WLHP. The results are tabulated and conclusion drawn is presented based on the performance.

  18. A Study Effects Architectural Marketing Capabilities on Performance Marketing unit Based on: Morgan et al case: Past Industry in Tehran

    OpenAIRE

    Mohammad Reza Dalvi; Robabe Seifi

    2014-01-01

    Over a period of time architectural marketing capabilities combination of knowledge and skills develop in to capabilities. These architectural marketing capabilities have been identified as one of the important ways firms can achieve a competitive advantage The following research tests effects architectural marketing capabilities on performance marketing unit Based on a survey .a structural equation model was developed to test our hypotheses. the study develops a structural model linking arch...

  19. Unit physics performance of a mix model in Eulerian fluid computations

    Energy Technology Data Exchange (ETDEWEB)

    Vold, Erik [Los Alamos National Laboratory; Douglass, Rod [Los Alamos National Laboratory

    2011-01-25

    In this report, we evaluate the performance of a K-L drag-buoyancy mix model, described in a reference study by Dimonte-Tipton [1] hereafter denoted as [D-T]. The model was implemented in an Eulerian multi-material AMR code, and the results are discussed here for a series of unit physics tests. The tests were chosen to calibrate the model coefficients against empirical data, principally from RT (Rayleigh-Taylor) and RM (Richtmyer-Meshkov) experiments, and the present results are compared to experiments and to results reported in [D-T]. Results show the Eulerian implementation of the mix model agrees well with expectations for test problems in which there is no convective flow of the mass averaged fluid, i.e., in RT mix or in the decay of homogeneous isotropic turbulence (HIT). In RM shock-driven mix, the mix layer moves through the Eulerian computational grid, and there are differences with the previous results computed in a Lagrange frame [D-T]. The differences are attributed to the mass averaged fluid motion and examined in detail. Shock and re-shock mix are not well matched simultaneously. Results are also presented and discussed regarding model sensitivity to coefficient values and to initial conditions (IC), grid convergence, and the generation of atomically mixed volume fractions.

  20. Sublimator Driven Coldplate Engineering Development Unit Test Results and Development of Second Generation SDC

    Science.gov (United States)

    Stephan, Ryan A.; Sheth, Rubik B.

    2009-01-01

    The Sublimator Driven Coldplate (SDC) is a unique piece of thermal control hardware that has several advantages over a traditional thermal control scheme. The principal advantage is the possible elimination of a pumped fluid loop, potentially increasing reliability and reducing complexity while saving both mass and power. Furthermore, the Integrated Sublimator Driven Coldplate (ISDC) concept couples a coolant loop with the previously described SDC hardware. This combination allows the SDC to be used as a traditional coldplate during long mission phases. The previously developed SDC technology cannot be used for long mission phases due to the fact that it requires a consumable feedwater for heat rejection. Adding a coolant loop also provides for dissimilar redundancy on the Altair Lander ascent module thermal control system, which is the target application for this technology. Tests were performed on an Engineering Development Unit at NASA s Johnson Space Center to quantify and assess the performance of the SDC. Correlated thermal math models were developed to help explain the test data. The paper also outlines the preliminary results of an ISDC concept being developed.

  1. 76 FR 82323 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units

    Science.gov (United States)

    2011-12-30

    ... Filtration and Adsorption Units AGENCY: Nuclear Regulatory Commission. ACTION: Draft regulatory guide... for Air Filtration and Adsorption Units of Postaccident Engineered-Safety-Feature Atmosphere Cleanup... testing of air filtration and iodine adsorption units of engineered-safety-feature (ESF) atmosphere...

  2. Construction of a dead-end type micro- to R.O. membrane test cell and performance test with the laboratory- made and commercial membranes

    Directory of Open Access Journals (Sweden)

    Darunee Bhongsuwan

    2002-11-01

    Full Text Available A dead-end type membrane stirred cell for an RO filtration test has been designed and constructed. Magnetic stirring system is applied to overcome a pressure-induced concentration polarization occurred over a membrane surface in the test cell. A high pressure N2 tank is used as a pressure source.Feed container is designed for 2.5 l feed solution and a stirred cell volume is 0.5 l . The test cell holds a magnetic stirrer freely moved over the membrane surface. All units are made of stainless steel. A porous SS316L disc is used as a membrane support. The dead-end stirred cell is tested to work properly in an operating pressure ranged 0 - 400 psi. It means that the dead-end cell can be used to test a membrane of different filtration modes, from micro- to Reverse Osmosis filtration. Tests performed at 400 psi for 3 hours are safe but tests at a 500 psi increase leakage possibility. The cell is used to test the performance of both commercial and laboratory-made membranes. It shows that the salt rejection efficiency of the nano- and RO membranes, NTR759HR and LES90, determined by using the new test cell, is closely similar to those reported from the manufacture. Result of the tests for our own laboratory-made membrane shows a similar performance to the nanofiltration membrane LES90.

  3. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  4. Development of Thermal Performance Analysis Computer Program on Turbine Cycle of Yoggwang 3,4 Units

    Energy Technology Data Exchange (ETDEWEB)

    Hong, S.Y.; Choi, K.H.; Jee, M.H.; Chung, S.I. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    The objective of the study ''Development of Thermal Performance Analysis Computer Program on Turbine Cycle of Yonggwang 3,4 Units'' is to utilize computerized program to the performance test of the turbine cycle or the analysis of the operational status of the thermal plants. In addition, the result can be applicable to the analysis of the thermal output at the abnormal status and be a powerful tool to find out the main problems for such cases. As a results, the output of this study can supply the way to confirm the technical capability to operate the plants efficiently and to obtain the economic gains remarkably. (author). 27 refs., 73 figs., 6 tabs.

  5. Frameworks for Performing on Cloud Automated Software Testing Using Swarm Intelligence Algorithm: Brief Survey

    Directory of Open Access Journals (Sweden)

    Mohammad Hossain

    2018-04-01

    Full Text Available This paper surveys on Cloud Based Automated Testing Software that is able to perform Black-box testing, White-box testing, as well as Unit and Integration Testing as a whole. In this paper, we discuss few of the available automated software testing frameworks on the cloud. These frameworks are found to be more efficient and cost effective because they execute test suites over a distributed cloud infrastructure. One of the framework effectiveness was attributed to having a module that accepts manual test cases from users and it prioritize them accordingly. Software testing, in general, accounts for as much as 50% of the total efforts of the software development project. To lessen the efforts, one the frameworks discussed in this paper used swarm intelligence algorithms. It uses the Ant Colony Algorithm for complete path coverage to minimize time and the Bee Colony Optimization (BCO for regression testing to ensure backward compatibility.

  6. Field Evaluation of the Performance of the RTU Challenge Unit: Daikin Rebel

    Energy Technology Data Exchange (ETDEWEB)

    Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ngo, Hung [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Underhill, Ronald M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-31

    Packaged rooftop air-conditioning units (RTUs) are used in 44% (2.5 million) of all commercial buildings, serving over 57% (46 billion square feet) of the commercial building floor space in the United States (EIA 2012). The primary energy consumption associated with RTUs is over 2.2 quads annually. Therefore, even a small improvement in efficiency or part-load operation of these units can lead to significant reductions in energy use and carbon emissions. Starting in 2011, the U.S. Department of Energy’s (DOE’s) Building Technologies Office funded a series of projects related to RTUs. Some projects were intended to improve the operating efficiency of the existing RTUs, while others were focused on improving the operating efficiency of new units. This report documents the field-testing and comparison of the seasonal efficiency of a state-of-art RTU Challenge unit and a standard unit. Section II provides the background for the work. Section III describes the measurement and verification plan for the field tests. Section IV describes the measurement and verification evaluation plan. The results are described in Section V. The lessons learned and recommendations for future work are presented in Section VI. A list of references is provided in Section VII.

  7. Environmental safety analysis tests on the Light Weight Radioisotope Heater Unit (LWRHU)

    International Nuclear Information System (INIS)

    Tate, R.E.; Land, C.C.

    1985-05-01

    A series of safety tests has been performed on the Light Weight Radioisotope Heater Unit (LWRHU), a 238 PuO 2 -fueled device designed to provide thermal energy at selected locations in a spacecraft. The tests simulate the thermal and mechanical environments postulated for spacecraft accidents on the launch pad and on reentry abort. The tests demonstrate almost complete containment of the fuel, or fuel simulant (depleted UO 2 ), in (1) an overpressure environment of 12.76 MPa (1850 psi), (2) on impact by an 18-g aluminum fuel-tank fragment at velocities greater than 750 m/s (2460 ft/s) but less than 900 m/s (2950 ft/s), (3) during a 10.5-min burn of a 0.9 x 0.9 x 0.9 m (3 x 3 x 3 ft) block of solid rocket motor propellant, (4) after impact at 49 m/s (161 ft/s) in four different orientations on a hard surface, and (5) during immersion in seawater for 1.75 years at both sea level pressure and at a pressure equivalent to 6000 m (19,700 ft) of ocean depth

  8. Vitrification Facility integrated system performance testing report

    International Nuclear Information System (INIS)

    Elliott, D.

    1997-01-01

    This report provides a summary of component and system performance testing associated with the Vitrification Facility (VF) following construction turnover. The VF at the West Valley Demonstration Project (WVDP) was designed to convert stored radioactive waste into a stable glass form for eventual disposal in a federal repository. Following an initial Functional and Checkout Testing of Systems (FACTS) Program and subsequent conversion of test stand equipment into the final VF, a testing program was executed to demonstrate successful performance of the components, subsystems, and systems that make up the vitrification process. Systems were started up and brought on line as construction was completed, until integrated system operation could be demonstrated to produce borosilicate glass using nonradioactive waste simulant. Integrated system testing and operation culminated with a successful Operational Readiness Review (ORR) and Department of Energy (DOE) approval to initiate vitrification of high-level waste (HLW) on June 19, 1996. Performance and integrated operational test runs conducted during the test program provided a means for critical examination, observation, and evaluation of the vitrification system. Test data taken for each Test Instruction Procedure (TIP) was used to evaluate component performance against system design and acceptance criteria, while test observations were used to correct, modify, or improve system operation. This process was critical in establishing operating conditions for the entire vitrification process

  9. Performance of Canadian commercial nuclear units and heavy water plants

    International Nuclear Information System (INIS)

    Woodhead, L.W.; Ingolfsrud, L.J.

    The operating history of Canadian commercial CANDU type reactors, i.e. Pickering generating station-A, is described. Capacity factors and unit energy costs are analyzed in detail. Equipment performance highlights are given. The performance of the two Canadian heavy water plants is described and five more are under construction or planned. (E.C.B.)

  10. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Hun [Kaya University, Gimhae (Korea, Republic of); Im, In Chul [Gwangju Health College University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Chosun University, Gwangju (Korea, Republic of); Kang, Se Sik [College of Health Science, Catholic University of Pusan, Busan (Korea, Republic of)

    2009-03-15

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  11. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    International Nuclear Information System (INIS)

    Park, Ju Hun; Im, In Chul; Dong, Kyung Rae; Kang, Se Sik

    2009-01-01

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  12. RELATIONSHIPS BETWEEN FUNCTIONAL MOVEMENT TESTS AND PERFORMANCE TESTS IN YOUNG ELITE MALE BASKETBALL PLAYERS.

    Science.gov (United States)

    Gonzalo-Skok, Oliver; Serna, Jorge; Rhea, Matthew R; Marín, Pedro J

    2015-10-01

    Sprinting and jumping are two common and important components of high-level sport performance. The weight-bearing dorsiflexion test (WB-DF) and Star Excursion Balance Test (SEBT) are tools developed to identify athletes at risk for lower extremity injury and may be related to running and jumping performance among athletes. The purposes of the present study were: 1) to identify any relationships between functional movement tests (WB-DF and SEBT) and performance tests (jumping, sprinting and changing direction); 2) to examine any relationships between asymmetries in functional movements and performance tests. Descriptive cohort study. Fifteen elite male basketball players (age: 15.4 ± 0.9 years) were assessed during a three-week period to determine the reliability of functional screening tools and performance tests and to examine the relationships between these tests. Relative (intraclass correlation coefficient) and absolute (coefficient of variation) reliability were used to assess the reproducibility of the tests. Significant correlations were detected between certain functional movement tests and performance tests. Both left and right excursion composite scores related to slower performance times in sprint testing, demonstrating that greater dynamic reach relates to decreased quickness and acceleration among these elite basketball athletes. The various relationships between dynamic functional movement testing, speed, and jump performance provide guidance for the strength and conditioning professional when conducting and evaluating data in an effort to improve performance and reduce risk of injury. The results of the present study suggest that these functional and performance tests do not measure the same components of human movement, and could be paired as outcome measures for the clinical and sport assessment of lower extremity function. 2b.

  13. Reactor coolant system hydrostatic test and risk analysis for the first AP1000 unit

    International Nuclear Information System (INIS)

    Cao Hongjun; Yan Xiuping

    2013-01-01

    The cold hydrostatic test scheme of the primary coolant circuit, of the first AP1000 unit was described. Based on the up-stream design documents, standard specifications and design technical requirements, the select principle of test boundary was identified. The design requirements for water quality, pressure, temperature and temporary hydro-test pump were proposed. A reasonable argument for heating and pressurization rate, and cooling and depressurization rate was proposed. The possible problems and risks during the hydrostatic test were analyzed. This test scheme can provide guidance for the revisions and implementations of the follow-up test procedures. It is a good reference for hydrostatic tests of AP1000 units in the future in China. (authors)

  14. SORO post-simulations of Bruce A Unit 4 in-core flux detector verification tests

    Energy Technology Data Exchange (ETDEWEB)

    Braverman, E.; Nainer, O. [Bruce Power, Nuclear Safety Analysis and Support Dept., Toronto, Ontario (Canada)]. E-mail: Evgeny.Braverman@brucepower.com; Ovidiu.Nainer@brucepower.com

    2004-07-01

    During the plant equipment assessment prior to requesting approval for restart of Bruce A Units 3 and 4 it was determined that all in-core flux detectors needed to be replaced. Flux detector verification tests were performed to confirm that the newly installed detectors had been positioned according to design specifications and that their response closely follows the calculated flux shape changes caused by selected reactivity mechanism movements. By comparing the measured and post-simulated RRS and NOP detector responses to various perturbations, it was confirmed that the new detectors are wired and positioned correctly. (author)

  15. "Individualized Science" Field Test Findings and Recommendations, the Hooke Unit. Appendix A.

    Science.gov (United States)

    Loue, William E., III

    This informal report contains the findings and recommendations resulting from the field test of the Hooke Unit of the "Individualized Science" program. Data were collected from three schools. Because of an unusual number of weaknesses ranging from formal inconsistencies to manipulative deficiencies, it was concluded that the Hooke Unit is somewhat…

  16. A pairwise unit-root-test based approach to investigating convergence of household debts in South Africa and the United States

    Directory of Open Access Journals (Sweden)

    Ntebogang Dinah Moroke

    2015-05-01

    Full Text Available The purpose of this paper was to test convergence of household debts in the United States and South Africa taking a pairwise unit root tests based approaches into account. Substantial number of studies dealt with convergence of several macroeconomic variables but to my knowledge no study considered this subject with respect to household debts of the identified countries. Quarterly data on household debts consisting of 88 observations in the South Africa and United States spanning the period 1990 to 2013 was collected from the South African and St. Louis Federal Reserve Banks. Focused on the absolute value of household debts, this study proved that South Africa is far from catching-up with the United States in terms of overcoming household debts for the selected period. The findings of this study can be used by relevant authorities to help improve ways and means of dealing with household debts South Africa

  17. Rankings of International Achievement Test Performance and Economic Strength: Correlation or Conjecture?

    Directory of Open Access Journals (Sweden)

    CHRISTOPHER H. TIENKEN

    2008-04-01

    Full Text Available Examining a popular political notion, this article presents results from a series of Spearman Rho calculations conducted to investigate relationships between countries’ rankings on international tests of mathematics and science and future economic competitiveness as measured by the 2006 World Economic Forum’s Growth Competitiveness Index (GCI. The study investigated the existence of relationships between international test rankings from three different time periods during the last 50 years of U.S. education policy development (i.e., 1957–1982, 1983–2000, and 2001–2006 and 2006 GCI ranks. It extends previous research on the topic by investigating how GCI rankings in the top 50 percent and bottom 50 percent relate to rankings on international tests for the countries that participated in each test. The study found that the relationship between ranks on international tests of mathematics and science and future economic strength is stronger among nations with lower-performing economies. Nations with strong economies, such as the United States, demonstrate a weaker, nonsignificant relationship.

  18. WIPP [Waste Isolation Pilot Plant] test phase plan: Performance assessment

    International Nuclear Information System (INIS)

    1990-04-01

    The U.S. Department of Energy (DOE) is responsible for managing the disposition of transuranic (TRU) wastes resulting from nuclear weapons production activities of the United States. These wastes are currently stored nationwide at several of the DOE's waste generating/storage sites. The goal is to eliminate interim waste storage and achieve environmentally and institutionally acceptable permanent disposal of these TRU wastes. The Waste Isolation Pilot Plant (WIPP) in southeastern New Mexico is being considered as a disposal facility for these TRU wastes. This document describes the first of the following two major programs planned for the Test Phase of WIPP: Performance Assessment -- determination of the long-term performance of the WIPP disposal system in accordance with the requirements of the EPA Standard; and Operations Demonstration -- evaluation of the safety and effectiveness of the DOE TRU waste management system's ability to emplace design throughput quantities of TRU waste in the WIPP underground facility. 120 refs., 19 figs., 8 tabs

  19. Performance Testing of Download Services of COSMC

    Directory of Open Access Journals (Sweden)

    Jiří Horák

    2013-11-01

    Full Text Available The paper presents results of performance tests of download services of Czech Office of Surveying, Mapping and Cadastre according to INSPIRE  requirements. Methodology of testing is explained, including monitoring performance  of reference servers. 26 millions of random requests were generated for each monitored operation, layer and coordinate system. The temporal development of performance indicators are analyzed and discussed. Results of performance tests approve the compliance with INSPIRE qualitative requirements for download services. All monitored services satisfy requirements of latency, capacity and availability. The latency and availability requirements are fulfilled with an abundant reserve. No problems in structure and content of responses were detected.

  20. System Performance and Testing

    NARCIS (Netherlands)

    Frei, U.; Oversloot, H.

    2004-01-01

    This chapter compares and contrasts the system performance of two widely used solar thermal systems using testing and simulation programs. Solar thermal systems are used in many countries for heating domestically used water. In addition to the simple thermosiphon systems, better designed pumped

  1. 29 CFR 1919.28 - Unit proof tests-cranes and gear accessory thereto.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof tests-cranes and gear accessory thereto. 1919.28... Loads; Heat Treatment; Competent Persons § 1919.28 Unit proof tests—cranes and gear accessory thereto. (a) Except as noted in paragraph (e) of this section, cranes and other hoisting machines, together...

  2. Accounting for health-care outcomes: implications for intensive care unit practice and performance.

    Science.gov (United States)

    Sorensen, Roslyn; Iedema, Rick

    2010-08-01

    The aim of this study was to understand the environment of health care, and how clinicians and managers respond in terms of performance accountability. A qualitative method was used in a tertiary metropolitan teaching intensive care unit (ICU) in Sydney, Australia, including interviews with 15 clinical managers and focus groups with 29 nurses of differing experience. The study found that a managerial focus on abstract goals, such as budgets detracted from managing the core business of clinical work. Fractures were evident within clinical units, between clinical units and between clinical and managerial domains. These fractures reinforced the status quo where seemingly unconnected patient care activities were undertaken by loosely connected individual clinicians with personalized concepts of accountability. Managers must conceptualize health services as an interconnected entity within which self-directed teams negotiate and agree objectives, collect and review performance data and define collective practice. Organically developing regimens of care within and across specialist clinical units, such as in ICUs, directly impact upon health service performance and accountability.

  3. Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  4. The Use of Performance Based Funding in a Sport Organization: A Case Study of the United States Olympic Committee

    Science.gov (United States)

    2009-08-01

    description and analysis of a single instance, phenomenon, or social unit (Merriam, 1998). Management by Objective (MBO). A control system designed to...theoretical principles of performance based funding instead of testing a hypothesis, my epistemology will be constructivist. Constructionism Maynard...operate. This constitutes a vital epistemological position that constructionism takes in relation to the interaction between the investigator and

  5. Test anxiety, perfectionism, goal orientation, and academic performance.

    Science.gov (United States)

    Eum, KoUn; Rice, Kenneth G

    2011-03-01

    Dimensions of perfectionism and goal orientation have been reported to have differential relationships with test anxiety. However, the degree of inter-relationship between different dimensions of perfectionism, the 2 × 2 model of goal orientations proposed by Elliot and McGregor, cognitive test anxiety, and academic performance indicators is not known. Based on data from 134 university students, we conducted correlation and regression analyses to test associations between adaptive and maladaptive perfectionism, four types of goal orientations, cognitive test anxiety, and two indicators of academic performance: proximal cognitive performance on a word list recall test and distal academic performance in terms of grade point average. Cognitive test anxiety was inversely associated with both performance indicators, and positively associated with maladaptive perfectionism and avoidance goal orientations. Adaptive and maladaptive perfectionism accounted for significant variance in cognitive test anxiety after controlling for approach and avoidance goal orientations. Overall, nearly 50% of the variance in cognitive test anxiety could be attributed to gender, goal orientations, and perfectionism. Results suggested that students who are highly test anxious are likely to be women who endorse avoidance goal orientations and are maladaptively perfectionistic.

  6. Performance testing With JMeter 29

    CERN Document Server

    Erinle, Bayo

    2013-01-01

    Performance Testing With JMeter 2.9 is a standard tutorial that will help you polish your fundamentals, guide you through various advanced topics, and along the process help you learn new tools and skills.This book is for developers, quality assurance engineers, testers, and test managers new to Apache JMeter, or those who are looking to get a good grounding in how to effectively use and become proficient with it. No prior testing experience is required.

  7. Addendum to ''Test Plan: Small-Scale Seal Performance Tests (SSSPT)''

    International Nuclear Information System (INIS)

    Finley, R.E.

    1992-01-01

    This document describes activities that are intended to update the data base of fluid flow measurements made on expansive salt concrete (ESC) seals as part of the Small-Scale Seal Performance Tests (SSSPT). The original plans for the SSSPT experiments are described by Stormont (1985a and 1985b). These seals have previously been tested with brine and gas during the early stages (less than 450 days) after emplacement. The purpose of this Test Plan Addendum is to detail the activities necessary to, update the gas and brine measurements previously performed on the SSSPT Series A and Series B seals and to identify the key personnel responsible for implementing these activities. This addendum describes a limited undertaking and does NOT change the scope of the original test plan

  8. Aquifer test plan for the 100-HR-3 Operable Unit

    International Nuclear Information System (INIS)

    Swanson, L.C.; Hartman, M.J.

    1994-01-01

    This test plan directs hydrologic testing activities planned at three existing Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) wells in the 100-HR-3 Operable Unit of the Hanford Site. Three additional wells will be installed near these existing wells and used as additional testing arid observation points during the field activities. Figure 1 shows the locations of the three test sites. A primary objective of the testing program is to provide more detailed hydraulic characterization information for the unconfined aquifer and targeted test sites than provided by the initial reconnaissance-level slug testing of Vukelich. A second objective is to evaluate the applicability of slug interference and dipole flow tests for detailed hydraulic characterization in an unconfined aquifer. This aquifer testing program will also be useful for substantiating hydraulic conductivities reported from previous slug tests and evaluating the effects of filter pack volume/configuration on slug test data. Vukelich recommended additional testing to address the latter two issues

  9. Numerical distribution functions of fractional unit root and cointegration tests

    DEFF Research Database (Denmark)

    MacKinnon, James G.; Nielsen, Morten Ørregaard

    We calculate numerically the asymptotic distribution functions of likelihood ratio tests for fractional unit roots and cointegration rank. Because these distributions depend on a real-valued parameter, b, which must be estimated, simple tabulation is not feasible. Partly due to the presence...

  10. Correlation of Neonatal Intensive Care Unit Performance Across Multiple Measures of Quality of Care

    Science.gov (United States)

    Profit, J; Zupancic, JAF; Gould, JB; Pietz, K; Kowalkowski, MA; Draper, D; Hysong, SJ; Petersen, LA

    2014-01-01

    Objectives To examine whether high performance on one measure of quality is associated with high performance on others and to develop a data-driven explanatory model of neonatal intensive care unit (NICU) performance. Design We conducted a cross-sectional data analysis of a statewide perinatal care database. Risk-adjusted NICU ranks were computed for each of 8 measures of quality selected based on expert input. Correlations across measures were tested using the Pearson correlation coefficient. Exploratory factor analysis was used to determine whether underlying factors were driving the correlations. Setting Twenty-two regional NICUs in California. Patients In total, 5445 very low-birth-weight infants cared for between January 1, 2004, and December 31, 2007. Main Outcomes Measures Pneumothorax, growth velocity, health care–associated infection, antenatal corticosteroid use, hypothermia during the first hour of life, chronic lung disease, mortality in the NICU, and discharge on any human breast milk. Results The NICUs varied substantially in their clinical performance across measures of quality. Of 28 unit-level correlations only 6 were significant (P quality measures were strong (ρ > .5) for 1 pair, moderate (.3 quality in this sample. Pneumothorax, mortality in the NICU, and antenatal corticosteroid use loaded on factor 1; growth velocity and health care–associated infection loaded on factor 2; chronic lung disease loaded on factor 3; and discharge on any human breast milk loaded on factor 4. Conclusion In this sample, the ability of individual measures of quality to explain overall quality of neonatal intensive care was modest. PMID:23403539

  11. Numerical analysis of the influence of PAR unit elevation within a vessel on its performance

    International Nuclear Information System (INIS)

    Kotouč, Miroslav

    2011-01-01

    On the basis of successful validation of the MELCOR code on several experiments from the international OECD/NEA programme THAI, a numerical parametric study has been conducted at NRI Řež evaluating the influence of PAR's vertical position within a vessel on its performance. Simulations were carried out for an Areva PAR unit which was considered to be placed at 5 different elevations in the THAI test vessel, the sixth simulation comprised a model of blower, simulating thus forced convection. The initial conditions were those of the THAI HR-12 test, which was characterized by steam-saturated atmosphere at elevated pressure and temperature. The results show that the overall hydrogen mass recombined monotonically decreases with PAR elevation. This behavior is due to hot, light and hydrogen-lean plume, coming out from the PAR outlet, which, due to buoyancy forces, eventually fills the upper part of the vessel and prevents thus the PAR unit from efficient operation (if the latter is placed near the top). It was also demonstrated that the effect of forced convection is favorable since it breaks the gas stratification and increases thus hydrogen concentration at the PAR inlet. (author)

  12. United States Nuclear Tests, July 1945 through September 1992, December 2000

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Nevada Operations Office

    2000-12-01

    This document list chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. Revision 15, dated December 2000.

  13. The VUV instrument SPICE for Solar Orbiter: performance ground testing

    Science.gov (United States)

    Caldwell, Martin E.; Morris, Nigel; Griffin, Douglas K.; Eccleston, Paul; Anderson, Mark; Pastor Santos, Carmen; Bruzzi, Davide; Tustain, Samuel; Howe, Chris; Davenne, Jenny; Grundy, Timothy; Speight, Roisin; Sidher, Sunil D.; Giunta, Alessandra; Fludra, Andrzej; Philippon, Anne; Auchere, Frederic; Hassler, Don; Davila, Joseph M.; Thompson, William T.; Schuehle, Udo H.; Meining, Stefan; Walls, Buddy; Phelan, P.; Dunn, Greg; Klein, Roman M.; Reichel, Thomas; Gyo, Manfred; Munro, Grant J.; Holmes, William; Doyle, Peter

    2017-08-01

    SPICE is an imaging spectrometer operating at vacuum ultraviolet (VUV) wavelengths, 70.4 - 79.0 nm and 97.3 - 104.9 nm. It is a facility instrument on the Solar Orbiter mission, which carries 10 science instruments in all, to make observations of the Sun's atmosphere and heliosphere, at close proximity to the Sun, i.e to 0.28 A.U. at perihelion. SPICE's role is to make VUV measurements of plasma in the solar atmosphere. SPICE is designed to achieve spectral imaging at spectral resolution >1500, spatial resolution of several arcsec, and two-dimensional FOV of 11 x16arcmins. The many strong constraints on the instrument design imposed by the mission requirements prevent the imaging performance from exceeding those of previous instruments, but by being closer to the sun there is a gain in spatial resolution. The price which is paid is the harsher environment, particularly thermal. This leads to some novel features in the design, which needed to be proven by ground test programs. These include a dichroic solar-transmitting primary mirror to dump the solar heat, a high in-flight temperature (60deg.C) and gradients in the optics box, and a bespoke variable-line-spacing grating to minimise the number of reflective components used. The tests culminate in the systemlevel test of VUV imaging performance and pointing stability. We will describe how our dedicated facility with heritage from previous solar instruments, is used to make these tests, and show the results, firstly on the Engineering Model of the optics unit, and more recently on the Flight Model. For the keywords, select up to 8 key terms for a search on your manuscript's subject.

  14. Performance/Power Space Exploration for Binary64 Division Units

    DEFF Research Database (Denmark)

    Nannarelli, Alberto

    2016-01-01

    The digit-recurrence division algorithm is used in several high-performance processors because it provides good tradeoffs in terms of latency, area and power dissipation. In this work we develop a minimally redundant radix-8 divider for binary64 (double-precision) aiming at obtaining better energy...... efficiency in the performance-per-watt space. The results show that the radix-8 divider, when compared to radix-4 and radix-16 units, requires less energy to complete a division for high clock rates....

  15. Unit thermal performance of atmospheric spray cooling systems

    International Nuclear Information System (INIS)

    Porter, R.W.; Jain, M.; Chaturvedi, S.K.

    1980-01-01

    Thermal performance of an open atmospheric spray pond or canal depends on the direct-contact evaporative cooling of an individual spray unit (spray nozzle or module) and the interference caused by local heating and humidification. Droplet parameters may be combined into a dimensionless group, number of transfer units (NTU) or equivalent, whereas large-scale air-vapor dynamics determine interference through the local wet-bulb temperature. Quantity NTU were implied from field experiments for a floating module used in steam-condenser spray canals. Previous data were available for a fixed-pipe nozzle assembly used in spray ponds. Quantity NTU were also predicted using the Ranz-Marshall correlations with the Sauter-mean diameter used as the characteristic length. Good agreement with experiments was shown for diameters of 1--1.1 cm (module) and 1.9 mm

  16. Current Status and Performance Tests of Korea Heat Load Test Facility KoHLT-EB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sukkwon; Jin, Hyunggon; Shin, Kyuin; Choi, Boguen; Lee, Eohwak; Yoon, Jaesung; Lee, Dongwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Duckhoi; Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    A commissioning test has been scheduled to establish the installation and preliminary performance experiments of the copper hypervapotron mockups. And a qualification test will be performed to evaluate the CuCrZr duct liner in the ITER neutral beam injection facility and the ITER first wall small-scale mockups of the semi-prototype, at up to 1.5 and 5 MW/m{sup 2} high heat flux. Also, this system will be used to test other PFCs for ITER and materials for tokamak reactors. Korean high heat flux test facility(KoHLT-EB; Korea Heat Load Test facility - Electron Beam) by using an electron beam system has been constructed in KAERI to perform the qualification test for ITER blanket FW semi-prototype mockups, hypervapotron cooling devices in fusion devices, and other ITER plasma facing components. The commissioning and performance tests with the supplier of e-gun system have been performed on November 2012. The high heat flux test for hypervapotron cooling device and calorimetry were performed to measure the surface heat flux, the temperature profile and cooling performance. Korean high heat flux test facility for the plasma facing components of nuclear fusion machines will be constructed to evaluate the performance of each component. This facility for the plasma facing materials will be equipped with an electron beam system with a 60 kV acceleration gun.

  17. Performance Test of CCTV in a Test Field

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyung Min [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2011-10-15

    On April 12-13, 2010, US President Obama hosted a Nuclear Security Summit in Washington, DC, to enhance international cooperation to prevent nuclear terrorism, an issue which he has identified as the most immediate and extreme threat to global security. The Summit focused on the security of nuclear materials, nonproliferation, disarmament, and peaceful nuclear energy. At the summit, the Republic of Korea was chosen as the host of the next Summit in 2012. This series of events reflects the growing global interest on 'Nuclear Security' and as the host country of the next Nuclear Summit it is the time for Korea to strengthen the physical protection regime for nuclear facilities as a first step of securing its nuclear security capability. KINAC has been operating Test field as a mean of preparing solid backup data for reviewing and revising DBT (Design Basis Threat) and to test components of the conventional physical protection system. CCTV is a key component which is used worldwide for the assessment measure of alarms. In terms of performance test of CCTV, there are several elements such as image quality, coverage and mechanical features (speed of zoom-in-out, capture, angle shift etc.). Speaking of image quality acquired by the CCTV, the quality is subject to resolution, monitor specification, camera housing, camera mounting and lightening. Thus it is clear that performance tests on image quality should consider those factors and vary the factors respectively in order to verify the influence and the interaction among those. Nevertheless due to the restrictions of the current Test field, this paper focuses on the image quality through resolution test under the various lightening conditions

  18. Performances on Rey Auditory Verbal Learning Test and Rey Complex Figure Test in a healthy, elderly Danish sample--reference data and validity issues

    DEFF Research Database (Denmark)

    Vogel, Asmus; Stokholm, Jette; Jørgensen, Kasper

    2012-01-01

    . The RCFT copy score was significantly related to age and the DART score. On RCFT recall a highly significant difference was found between persons who could make a faultless copy and persons with incomplete copy performance. Thus, this study presents separate data for RCFT recall scores according...... to the subjects' copying performance (in separate tables for age and education groups). For all measures on both RAVLT and RCFT wide distributions of scores were found and the impact of this broad score range on the tests' discriminative validity is discussed. RAVLT performances for elderly were similar...... to previous published meta-norms, but the included sample of elderly Danes performed better on RCFT (copy and recall) than elderly from the United States....

  19. Phasor Measurement Unit Test and Applications for Small Signal Stability Assessment and Improvement of Power System

    DEFF Research Database (Denmark)

    Ghiga, Radu

    to be less predictable. Therefore, the methods used for stability and security assessment will most likely use information from the wide-area measurements systems (WAMS). The work presented in this thesis deals on one hand with the development of test methods and validation of phasor measurement units (PMUs......) which are considered to be one of the key technologies in WAMS, and on the other hand with the possibility of using PMU measurements together with large wind power plants (WPPs) to help improve the damping of inter area oscillations. To validate the PMUs, a laboratory test setup is assembled....... The hardware components are capable of generating, with the required accuracy, the test signals injected in the PMUs. The signals are created according to the requirements defined in the current IEEE C37.118.1-2011 standard, to test the steady-state and dynamic compliance of the PMUs. The performance...

  20. [Evaluation of performance and false positivity of Mediace RPR test that uses a chemistry autoanalyzer].

    Science.gov (United States)

    Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young

    2008-08-01

    We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.

  1. United States Nuclear Tests, July 1945 through September 1992, September 2015

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2015-09-01

    This document lists chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. This is Revision 16, dated September 2015.

  2. Recommended procedures for performance testing of radiobioassay laboratories: Volume 3, In vivo test phantoms

    International Nuclear Information System (INIS)

    MacLellan, J.A.; Traub, R.J.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard describes the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay performance-testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the draft ANSI N13.30 performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of test phantoms used for calibration of measurement systems for direct bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented

  3. Load responsive multilayer insulation performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Dye, S.; Kopelove, A. [Quest Thermal Group, 6452 Fig Street Suite A, Arvada, CO 80004 (United States); Mills, G. L. [Ball Aerospace and Technologies Corp, 1600 Commerce Street, Boulder, CO 80301 (United States)

    2014-01-29

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

  4. Load responsive multilayer insulation performance testing

    International Nuclear Information System (INIS)

    Dye, S.; Kopelove, A.; Mills, G. L.

    2014-01-01

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI

  5. Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods provide special techniques needed to determine the electrical performance and spectral response of two-terminal, multijunction photovoltaic (PV) devices, both cell and modules. 1.2 These test methods are modifications and extensions of the procedures for single-junction devices defined by Test Methods E948, E1021, and E1036. 1.3 These test methods do not include temperature and irradiance corrections for spectral response and current-voltage (I-V) measurements. Procedures for such corrections are available in Test Methods E948, E1021, and E1036. 1.4 These test methods may be applied to cells and modules intended for concentrator applications. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and ...

  6. Relationships Between Anaerobic Performance, Field Tests and Game Performance of Sitting Volleyball Players

    Directory of Open Access Journals (Sweden)

    Marszalek Jolanta

    2015-12-01

    Full Text Available The aim of this study was to evaluate relationships between anaerobic performance, field tests, game performance and anthropometric variables of sitting volleyball players. Twenty elite Polish sitting volleyball players were tested using the 30 s Wingate Anaerobic Test for arm crank ergometer and participated in six physical field tests. Heights in position to block and to spike, as well as arm reach were measured. Players were observed during the game on the court in terms of effectiveness of the serve, block, attack, receive and defense. Pearson analysis and the Spearman's rank correlation coefficient were used. The strongest correlations were found between the chest pass test and mean power and peak power (r=.846; p=.001 and r=.708; p=.0005, respectively, and also between the T-test and peak power (r= −.718; p=.001. Mean power correlated with the 3 m test (r= −.540; p=.014, the 5 m test (r= −.592; p=.006, and the T-test (r= −.582; p=.007. Peak power correlated with the 3 m test (r= −.632; p=.003, the 5 m test (r= −.613; p=.004, speed & agility (r= −.552; p=.012 and speed & endurance (r=−.546; p=.013. Significant correlations were observed between anthropometric parameters and anaerobic performance variables (p≤.001, and also between anthropometric parameters and field tests (p≤.05. Game performance and physical fitness of sitting volleyball players depended on their anthropometric variables: reach of arms, the position to block and to spike. The chest pass test could be used as a non-laboratory field test of anaerobic performance of sitting volleyball players.

  7. Motor unit recruitment by size does not provide functional advantages for motor performance.

    Science.gov (United States)

    Dideriksen, Jakob L; Farina, Dario

    2013-12-15

    It is commonly assumed that the orderly recruitment of motor units by size provides a functional advantage for the performance of movements compared with a random recruitment order. On the other hand, the excitability of a motor neuron depends on its size and this is intrinsically linked to its innervation number. A range of innervation numbers among motor neurons corresponds to a range of sizes and thus to a range of excitabilities ordered by size. Therefore, if the excitation drive is similar among motor neurons, the recruitment by size is inevitably due to the intrinsic properties of motor neurons and may not have arisen to meet functional demands. In this view, we tested the assumption that orderly recruitment is necessarily beneficial by determining if this type of recruitment produces optimal motor output. Using evolutionary algorithms and without any a priori assumptions, the parameters of neuromuscular models were optimized with respect to several criteria for motor performance. Interestingly, the optimized model parameters matched well known neuromuscular properties, but none of the optimization criteria determined a consistent recruitment order by size unless this was imposed by an association between motor neuron size and excitability. Further, when the association between size and excitability was imposed, the resultant model of recruitment did not improve the motor performance with respect to the absence of orderly recruitment. A consistent observation was that optimal solutions for a variety of criteria of motor performance always required a broad range of innervation numbers in the population of motor neurons, skewed towards the small values. These results indicate that orderly recruitment of motor units in itself does not provide substantial functional advantages for motor control. Rather, the reason for its near-universal presence in human movements is that motor functions are optimized by a broad range of innervation numbers.

  8. Performance Recognition for Sulphur Flotation Process Based on Froth Texture Unit Distribution

    Directory of Open Access Journals (Sweden)

    Mingfang He

    2013-01-01

    Full Text Available As an important indicator of flotation performance, froth texture is believed to be related to operational condition in sulphur flotation process. A novel fault detection method based on froth texture unit distribution (TUD is proposed to recognize the fault condition of sulphur flotation in real time. The froth texture unit number is calculated based on texture spectrum, and the probability density function (PDF of froth texture unit number is defined as texture unit distribution, which can describe the actual textual feature more accurately than the grey level dependence matrix approach. As the type of the froth TUD is unknown, a nonparametric kernel estimation method based on the fixed kernel basis is proposed, which can overcome the difficulty when comparing different TUDs under various conditions is impossible using the traditional varying kernel basis. Through transforming nonparametric description into dynamic kernel weight vectors, a principle component analysis (PCA model is established to reduce the dimensionality of the vectors. Then a threshold criterion determined by the TQ statistic based on the PCA model is proposed to realize the performance recognition. The industrial application results show that the accurate performance recognition of froth flotation can be achieved by using the proposed method.

  9. Hydrologic resources management program and underground test area operable unit fy 1997

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D. F., LLNL

    1998-05-01

    This report present the results of FY 1997 technical studies conducted by the Lawrence Livermore National Laboratory (LLNL) as part of the Hydrology and Radionuclide Migration Program (HRMP) and Underground Test Area Operable Unit (UGTA). The HRMP is sponsored by the US Department of Energy to assess the environmental (radiochemical and hydrologic) consequences of underground nuclear weapons testing at the Nevada Test Site.

  10. Unit Root Testing in Heteroscedastic Panels Using the Cauchy Estimator

    NARCIS (Netherlands)

    Demetrescu, Matei; Hanck, Christoph

    The Cauchy estimator of an autoregressive root uses the sign of the first lag as instrumental variable. The resulting IV t-type statistic follows a standard normal limiting distribution under a unit root case even under unconditional heteroscedasticity, if the series to be tested has no

  11. Semiparametric Power Envelopes for Tests of the Unit Root Hypothesis

    DEFF Research Database (Denmark)

    Jansson, Michael

    This paper derives asymptotic power envelopes for tests of the unit root hypothesis in a zero-mean AR(1) model. The power envelopes are derived using the limits of experiments approach and are semiparametric in the sense that the underlying error distribution is treated as an unknown...

  12. Testing Game-Based Performance in Team-Handball.

    Science.gov (United States)

    Wagner, Herbert; Orwat, Matthias; Hinz, Matthias; Pfusterschmied, Jürgen; Bacharach, David W; von Duvillard, Serge P; Müller, Erich

    2016-10-01

    Wagner, H, Orwat, M, Hinz, M, Pfusterschmied, J, Bacharach, DW, von Duvillard, SP, and Müller, E. Testing game-based performance in team-handball. J Strength Cond Res 30(10): 2794-2801, 2016-Team-handball is a fast paced game of defensive and offensive action that includes specific movements of jumping, passing, throwing, checking, and screening. To date and to the best of our knowledge, a game-based performance test (GBPT) for team-handball does not exist. Therefore, the aim of this study was to develop and validate such a test. Seventeen experienced team-handball players performed 2 GBPTs separated by 7 days between each test, an incremental treadmill running test, and a team-handball test game (TG) (2 × 20 minutes). Peak oxygen uptake (V[Combining Dot Above]O2peak), blood lactate concentration (BLC), heart rate (HR), sprinting time, time of offensive and defensive actions as well as running intensities, ball velocity, and jump height were measured in the game-based test. Reliability of the tests was calculated using an intraclass correlation coefficient (ICC). Additionally, we measured V[Combining Dot Above]O2peak in the incremental treadmill running test and BLC, HR, and running intensities in the team-handball TG to determine the validity of the GBPT. For the test-retest reliability, we found an ICC >0.70 for the peak BLC and HR, mean offense and defense time, as well as ball velocity that yielded an ICC >0.90 for the V[Combining Dot Above]O2peak in the GBPT. Percent walking and standing constituted 73% of total time. Moderate (18%) and high (9%) intensity running in the GBPT was similar to the team-handball TG. Our results indicated that the GBPT is a valid and reliable test to analyze team-handball performance (physiological and biomechanical variables) under conditions similar to competition.

  13. Performance test for a solar water heater

    Science.gov (United States)

    1979-01-01

    Two reports describe procedures and results of performance tests on domestic solar powered hot water system. Performance tests determine amount of energy collected by system, amount of energy delivered to solar source, power required to operate system and maintain proper tank temperature, overall system efficiency, and temperature distribution in tank.

  14. Itegrated Test and Evaluation of a 4-Bed Molecular Sieve (4BMS) Carbon Dioxide Removtal System (CDRA), Mechanical Compressor Engineering Development Unit (EDU), and Sabitier Engineering Development Unit (EDU)

    Science.gov (United States)

    Knox, James C.; Campbell, Melissa; Murdoch, Karen; Miller, Lee A.; Jeng, Frank

    2005-01-01

    Currently on the International Space Station s (ISS) U.S. Segment, carbon dioxide (CO2) scrubbed from the cabin by a 4-Bed Molecular Sieve (4BMS) Carbon Dioxide Removal Assembly (CDRA) is vented overboard as a waste product. Likewise, the product hydrogen (H2) that will be generated by the Oxygen Generation Assembly (OGA) planned for installation will also be vented. A flight experiment has been proposed that will take the waste CO2 removed from the cabin, and via the catalytic Sabatier process, reduce it with waste H2 to generate water and methane. The water produced may provide cost and logistics savings for ISS by reducing the amount of water periodically re-supplied to orbit. To make this concept viable, a mechanical piston compressor and accumulator were developed for collecting and storing the CO2 from the CDRA. The compressor, accumulator and Sabatier system would be packaged together as one unit and referred to as the Carbon Dioxide Reduction Assembly (CRA). Testing was required to evaluate the performance of a 4BMS CDRA, compressor, accumulator, and Sabatier performance along with their operating rules when integrated together. This had been numerically modeled and simulated; however, testing was necessary to verify the results from the engineering analyses. Testing also allowed a better understanding of the practical inefficiencies and control issues involved in a fully integrated system versus the theoretical ideals in the model. This paper presents and discusses the results of an integrated engineering development unit test.

  15. Detailed design and first tests of the application software for the instrument control unit of Euclid-NISP

    Science.gov (United States)

    Ligori, S.; Corcione, L.; Capobianco, V.; Bonino, D.; Sirri, G.; Fornari, F.; Giacomini, F.; Patrizii, L.; Valenziano, L.; Travaglini, R.; Colodro, C.; Bortoletto, F.; Bonoli, C.; Chiarusi, T.; Margiotta, A.; Mauri, N.; Pasqualini, L.; Spurio, M.; Tenti, M.; Dal Corso, F.; Dusini, S.; Laudisio, F.; Sirignano, C.; Stanco, L.; Ventura, S.; Auricchio, N.; Balestra, A.; Franceschi, E.; Morgante, G.; Trifoglio, M.; Medinaceli, E.; Guizzo, G. P.; Debei, S.; Stephen, J. B.

    2016-07-01

    In this paper we describe the detailed design of the application software (ASW) of the instrument control unit (ICU) of NISP, the Near-Infrared Spectro-Photometer of the Euclid mission. This software is based on a real-time operating system (RTEMS) and will interface with all the subunits of NISP, as well as the command and data management unit (CDMU) of the spacecraft for telecommand and housekeeping management. We briefly review the main requirements driving the design and the architecture of the software that is approaching the Critical Design Review level. The interaction with the data processing unit (DPU), which is the intelligent subunit controlling the detector system, is described in detail, as well as the concept for the implementation of the failure detection, isolation and recovery (FDIR) algorithms. The first version of the software is under development on a Breadboard model produced by AIRBUS/CRISA. We describe the results of the tests and the main performances and budgets.

  16. Are brand-equity measures associated with business-unit financial performance? : Empirical Evidence from the Netherlands

    NARCIS (Netherlands)

    Verbeeten, F.H.M.; Vijn, P.

    2010-01-01

    We investigate the association between brand-equity measures and business-unit financial performance. Brand-equity measures may complement historic accounting information in explaining business-unit financial performance. Capitalizing on a unique data set, we find an association between some (yet

  17. Are brand-equity measures associated with business-unit financial performance? Empirical evidence from the Netherlands

    NARCIS (Netherlands)

    Verbeeten, Frank H M; Vijn, Pieter

    2010-01-01

    We investigate the association between brand-equity measures and business-unit financial performance. Brand-equity measures may complement historic accounting information in explaining business-unit financial performance. Capitalizing on a unique data set, we find an association between some (yet

  18. GEM: Performance and aging tests

    International Nuclear Information System (INIS)

    Cho, H.S.; Kadyk, J.; Han, S.H.; Hong, W.S.; Perez-Mendez, V.; Wenzel, W.; Pitts, K.; Martin, M.D.; Hutchins, J.B.

    1999-01-01

    Performance and aging tests have been done to characterize Gas Electron Multipliers (GEMs), including further design improvements such as a thicker GEM and a closed GEM. Since the effective GEM gain is typically smaller than the absolute GEM gain, due to trapping of avalanche electrons at the bottom GEM electrode, the authors performed field simulations and measurements for better understanding, and discuss methods to eliminate this effect. Other performance parameters of the GEMs are also presented, including absolute GEM gain, short-term and long-term gain stabilities

  19. Purchasing power parity in OECD countries: nonlinear unit root tests revisited

    OpenAIRE

    Juan Carlos Cuestas; Paulo José Regis

    2010-01-01

    The aim of this paper is to provide additional evidence on the purchasing power parity empirical fulfillment in a pool of OECD countries. We apply the Harvey et al. (2008) linearity test and the Kruse (2010) nonlinear unit root test. The results point to the fact that the purchasing power parity theory holds in a greater number of countries than has been reported in previous studies.

  20. Empirical investigation of purchasing power parity for Turkey: Evidence from recent nonlinear unit root tests

    Directory of Open Access Journals (Sweden)

    Dilem Yıldırım

    2017-06-01

    Full Text Available This study explores the empirical validity of the purchasing power parity (PPP hypothesis between Turkey and its four major trading partners, the European Union, Russia, China and the US. Accounting for the nonlinear nature of real exchange rates, we employ a battery of recently developed nonlinear unit root tests. Our empirical results reveal that nonlinear unit root tests deliver stronger evidence in favour of the PPP hypothesis when compared to the conventional unit root tests only if nonlinearities in real exchange rates are correctly specified. Furthermore, it emerges from our findings that the real exchange rates of the countries having a free trade agreement are more likely to behave as linear stationary processes.

  1. Lumped Parameter Modeling for Rapid Vibration Response Prototyping and Test Correlation for Electronic Units

    Science.gov (United States)

    Van Dyke, Michael B.

    2013-01-01

    Present preliminary work using lumped parameter models to approximate dynamic response of electronic units to random vibration; Derive a general N-DOF model for application to electronic units; Illustrate parametric influence of model parameters; Implication of coupled dynamics for unit/board design; Demonstrate use of model to infer printed wiring board (PWB) dynamics from external chassis test measurement.

  2. Performance testing framework for smart grid communication network

    International Nuclear Information System (INIS)

    Quang, D N; See, O H; Chee, L L; Xuen, C Y; Karuppiah, S

    2013-01-01

    Smart grid communication network is comprised of different communication mediums and technologies. Performance evaluation is one of the main concerns in smart grid communication system. In any smart grid communication implementation, to determine the performance factor of the network, a testing of an end-to-end process flow is required. Therefore, an effective and coordinated testing procedure plays a crucial role in evaluating the performance of smart grid communications. In this paper, a testing framework is proposed as a guideline to analyze and assess the performance of smart grid communication network.

  3. The influence of shyness on children's test performance.

    Science.gov (United States)

    Crozier, W Ray; Hostettler, Kirsten

    2003-09-01

    Research has shown that shy children differ from their peers not only in their use of language in routine social encounters but also in formal assessments of their language development, including psychometric tests of vocabulary. There has been little examination of factors contributing to these individual differences. To investigate cognitive-competence and social anxiety interpretations of differences in children's performance on tests of vocabulary. To examine the performance of shy and less shy children under different conditions of test administration, individually with an examiner or among their peers within the familiar classroom setting. The sample consisted of 240 Year 5 pupils (122 male, 118 female) from 24 primary schools. Shy and less shy children, identified by teacher nomination and checklist ratings, completed vocabulary and mental arithmetic tests in one of three conditions, in a between-subjects design. The conditions varied individual and group administration, and oral and written responses. The conditions of test administration influenced the vocabulary test performance of shy children. They performed significantly more poorly than their peers in the two face-to-face conditions but not in the group test condition. A comparable trend for the arithmetic test was not statistically significant. Across the sample as a whole, shyness correlated significantly with test scores. Shyness does influence children's cognitive test performance and its impact is larger when children are tested face-to-face rather than in a more anonymous group setting. The results are of significance for theories of shyness and have implications for the assessment of schoolchildren.

  4. 30 CFR 7.67 - Construction test.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Construction test. 7.67 Section 7.67 Mineral... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Multiple-Shot Blasting Units § 7.67 Construction test. The constuction test is to be performed on the blasting unit subsequent to the output energy test of...

  5. United States position paper on sodium fires, design and testing

    International Nuclear Information System (INIS)

    Hilliard, R.K.; Johnson, R.P.

    1983-01-01

    The first Specialists' Meeting on sodium fire technology sponsored by the International Working Group on Fast Reactors (IWGFR) was held in Richland, Washington in 1972. The group concluded that the state-of-technology at that time was inadequate to support the growing LMFBR industry. During the second IWGFR Specialists' Meeting on sodium fires, held in Cadarache, France in 1978, a large quantity of technical information was exchanged and areas were identified where additional work was needed. Advances in several important areas of sodium fire technology have been made in the United States since that time, including improved computer codes, design of a sodium fire protection system for the CRBRP, measurement of water release from heated concrete, and testing and modeling of the sodium-concrete reaction. Research in the U.S. related to sodium fire technology is performed chiefly at the Energy Systems Group of Rockwell International (including Atomics International), the Hanford Engineering Development Laboratory (HEDL), and the Sandia National Laboratories (SNL). The work at the first two laboratories is sponsored by the U.S. Department of Energy, while that at the latter is sponsored by the U.S. Nuclear Regulatory Commission. Various aspects of sodium fire related work is also performed at several other laboratories. The current status of sodium fire technology in the U.S. is summarized in this report

  6. Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test

    International Nuclear Information System (INIS)

    Bae, Kyoo Whan; Song, Jin Ho; Chung, Young Jong; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring in the downcomer with limited budget and time, the separate effects test focusing on this region is considered to be effective and the conceptual test facility based on this recommended. For this test facility the test initial and boundary conditions are developed using the CEFLASH-4AS/REM analysis results that will be used as input for the preliminary test requirements. The final test requirements will be developed through the further discussions with the test performance group. (Author). 10 refs., 18 tabs., 4 figs

  7. Tests Performed on Hydraulic Turbines at Commissioning or after Capital Repairs. Part II. Tests Performed on a 6.5 MW Kaplan Turbine

    Directory of Open Access Journals (Sweden)

    Adrian Cuzmoş

    2015-07-01

    Full Text Available The paper presents the tests performed on a hydraulic turbine on commissioning, the devices, test methods and the results obtained from the respective tests, as well as the conclusions and recommendations resulted from these tests. This kind of tests can be performed for the verification of guarantees.

  8. Performance testing of extremity dosimeters, Study 2

    International Nuclear Information System (INIS)

    Harty, R.; Reece, W.D.; Hooker, C.D.

    1990-04-01

    The Health Physics Society Standards Committee (HPSSC) Working Group on Performance Testing of Extremity Dosimeters has issued a draft of a proposed standard for extremity dosimeters. The draft standard proposes methods to be used for testing dosimetry systems that determine occupational radiation dose to the extremities and the performance criterion used to determine compliance with the standard. Pacific Northwest Laboratory (PNL) has conducted two separate evaluations of the performance of extremity dosimeter processors to determine the appropriateness of the draft standard, as well as to obtain information regarding the performance of extremity dosimeters. Based on the information obtained during the facility visits and the results obtained from the performance testing, it was recommended that changes be made to ensure that the draft standard is appropriate for extremity dosimeters. The changes include: subdividing the mixture category and the beta particle category; eliminating the neutron category until appropriate flux-to-dose equivalent conversion factors are derived; and changing the tolerance level for the performance criterion to provide consistency with the performance criterion for whole body dosimeters, and to avoid making the draft standard overly difficult for processors of extremity dosimeters to pass. 20 refs., 10 figs., 6 tabs

  9. Validity of purchasing power parity for selected Latin American countries: Linear and non-linear unit root tests

    Directory of Open Access Journals (Sweden)

    Claudio Roberto Fóffano Vasconcelos

    2016-01-01

    Full Text Available The aim of this study is to examine empirically the validity of PPP in the context of unit root tests based on linear and non-linear models of the real effective exchange rate of Argentina, Brazil, Chile, Colombia, Mexico, Peru and Venezuela. For this purpose, we apply the Harvey et al. (2008 linearity test and the non-linear unit root test (Kruse, 2011. The results show that the series with linear characteristics are Argentina, Brazil, Chile, Colombia and Peru and those with non-linear characteristics are Mexico and Venezuela. The linear unit root tests indicate that the real effective exchange rate is stationary for Chile and Peru, and the non-linear unit root tests evidence that Mexico is stationary. In the period analyzed, the results show support for the validity of PPP in only three of the seven countries.

  10. The Effects of Humor on Test Anxiety and Test Performance

    Science.gov (United States)

    Tali, Glenda

    2017-01-01

    Testing in an academic setting provokes anxiety in all students in higher education, particularly nursing students. When students experience high levels of anxiety, the resulting decline in test performance often does not represent an accurate assessment of students' academic achievement. This quantitative, experimental study examined the effects…

  11. Compressible Fluid Suspension Performance Testing

    National Research Council Canada - National Science Library

    Hoogterp, Francis

    2003-01-01

    ... compressible fluid suspension system that was designed and installed on the vehicle by DTI. The purpose of the tests was to evaluate the possible performance benefits of the compressible fluid suspension system...

  12. Evaluation of High-Performance Rooftop HVAC Unit Naval Air Station Key West, Florida

    Energy Technology Data Exchange (ETDEWEB)

    Howett, Daniel H. [ORNL; Desjarlais, Andre Omer [ORNL; Cox, Daryl [ORNL

    2018-01-01

    This report documents performance of a high performance rooftop HVAC unit (RTU) at Naval Air Station Key West, FL. This report was sponsored by the Federal Energy Management Program as part of the "High Performance RTU Campaign".

  13. The new VLT-DSM M2 unit: construction and electromechanical testing

    Science.gov (United States)

    Gallieni, Daniele; Biasi, Roberto

    2013-12-01

    We present the design, construction and validation of the new M2 unit of the VLT Deformable Secondary Mirror. In the framework of the Adaptive Optics Facility program, ADS and Microgate designed a new secondary unit which replaces the current Dornier one. The M2 is composed by the mechanical structure, a new hexapod positioner and the Deformable Secondary Mirror unit.The DSM is based on the well proven contactless, voice coil motor technology that has been already successfully implemented in the MMT, LBT and Magellan adaptive secondaries, and is considered a promising technical choice for the E-ELT M4 and the GMT ASM. The VLT adaptive unit has been fully integrated and, before starting the optical calibration, has completed the electromechanical characterization, focused on the dynamic performance. With respect to the previous units we introduced several improvements, both in hardware and control architecture that allowed achieving a significant enhancement of the system dynamics and reduction of power consumption.

  14. Examining the relationships between span of control and manager job and unit performance outcomes.

    Science.gov (United States)

    Wong, Carol A; Elliott-Miller, Pat; Laschinger, Heather; Cuddihy, Michael; Meyer, Raquel M; Keatings, Margaret; Burnett, Camille; Szudy, Natalie

    2015-03-01

    Our aim was to examine the combination of frontline manager (FLM) personal characteristics and span of control (SOC) on their job and unit performance outcomes. Healthcare downsizing and reform have contributed to larger spans for FLMs in Canadian hospitals and increased concerns about manager workload. Despite a heightened awareness of SOC issues among decision makers, there is limited empirical evidence related to the effects of SOC on outcomes. A non-experimental predictive survey design was used to examine FLM SOC in 14 Canadian academic hospitals. Managers (n = 121) completed an online survey of work characteristics and The Ottawa Hospital (TOH) SOC tool. Unit turnover data were collected from organisational databases. The combination of SOC and core self-evaluation significantly predicted role overload, work control and job satisfaction, but only SOC predicted unit adverse outcomes and neither significantly predicted unit turnover. The findings contribute to an understanding of connections between the combination of SOC and core self-evaluation and manager job and unit performance outcomes. Organisational strategies to create manageable FLM SOC are essential to ensure exemplary job and unit outcomes. Core self-evaluation is a personality characteristic that may enhance manager performance in the face of high spans of control. © 2013 John Wiley & Sons Ltd.

  15. Orion Exploration Flight Test-1 Post-Flight Navigation Performance Assessment Relative to the Best Estimated Trajectory

    Science.gov (United States)

    Gay, Robert S.; Holt, Greg N.; Zanetti, Renato

    2016-01-01

    This paper details the post-flight navigation performance assessment of the Orion Exploration Flight Test-1 (EFT-1). Results of each flight phase are presented: Ground Align, Ascent, Orbit, and Entry Descent and Landing. This study examines the on-board Kalman Filter uncertainty along with state deviations relative to the Best Estimated Trajectory (BET). Overall the results show that the Orion Navigation System performed as well or better than expected. Specifically, the Global Positioning System (GPS) measurement availability was significantly better than anticipated at high altitudes. In addition, attitude estimation via processing GPS measurements along with Inertial Measurement Unit (IMU) data performed very well and maintained good attitude throughout the mission.

  16. Design, Assembly, Integration, and Testing of a Power Processing Unit for a Cylindrical Hall Thruster, the NORSAT-2 Flatsat, and the Vector Gravimeter for Asteroids Instrument Computer

    Science.gov (United States)

    Svatos, Adam Ladislav

    This thesis describes the author's contributions to three separate projects. The bus of the NORSAT-2 satellite was developed by the Space Flight Laboratory (SFL) for the Norwegian Space Centre (NSC) and Space Norway. The author's contributions to the mission were performing unit tests for the components of all the spacecraft subsystems as well as designing and assembling the flatsat from flight spares. Gedex's Vector Gravimeter for Asteroids (VEGA) is an accelerometer for spacecraft. The author's contributions to this payload were modifying the instrument computer board schematic, designing the printed circuit board, developing and applying test software, and performing thermal acceptance testing of two instrument computer boards. The SFL's cylindrical Hall effect thruster combines the cylindrical configuration for a Hall thruster and uses permanent magnets to achieve miniaturization and low power consumption, respectively. The author's contributions were to design, build, and test an engineering model power processing unit.

  17. Work zone performance measures pilot test.

    Science.gov (United States)

    2011-04-01

    Currently, a well-defined and validated set of metrics to use in monitoring work zone performance do not : exist. This pilot test was conducted to assist state DOTs in identifying what work zone performance : measures can and should be targeted, what...

  18. Local control unit for ITER-India gyrotron test facility (IIGTF)

    Energy Technology Data Exchange (ETDEWEB)

    Rathod, Vipal, E-mail: vipal.rathod@iter-india.org; Shah, Ronak; Mandge, Deepak; Parmar, Rajvi; Rao, S.L.

    2016-11-15

    Highlights: • A dedicated full scale ITER prototype Local Control Unit for ITER-India Gyrotron test facility. • National Instruments® make PXIe system for real time control & data acquisition and Siemens® PLC for sequence control function. • Hardwired FPGA based fast protection interlock system. • High speed analog fiber optical transmission link using V/F and F/V technique. • Software framework based on LabVIEW™ platform and ITER CODAC Core System. - Abstract: Electron Cyclotron system on ITER, is one of the important RF ancillary systems based on high power Gyrotron RF sources, that is used for plasma heating and current drive applications. To operate a Gyrotron source, various auxiliary systems and services such as Super Conducting Magnet set, High Voltage Power Supplies, Auxiliary Power Supplies, Waveguide components, Cooling water system and a Local Control Unit (LCU) are required. The LCU plays a very crucial role for the safe and reliable operation of Gyrotron system. A dedicated full scale ITER prototype LCU is being developed for testing and commissioning of an ITER like Test Gyrotron at ITER-India Gyrotron Test facility (IIGTF). The main functions of LCU include Sequence Control, Local Interlock Protection and Real Time Data Acquisition. PLC based slow controller is used for implementing the Sequence Control & Slow Interlock functions. Critical Protection Interlocks are required to have a response time of <10 μs and are implemented using custom built hardware and PXIe based fast controller. Also PXIe system is used for implementing Real Time Data Acquisition function that is required to have slow and fast acquisition with online visualization and off line analysis facility. A Signal Conditioning Unit (SCU) is used to interface and faithfully transmit the field signals to the remote control systems. Necessary controller hardware is procured and several pre-prototype developments have been taken up to establish the critical subsystems such as

  19. Local control unit for ITER-India gyrotron test facility (IIGTF)

    International Nuclear Information System (INIS)

    Rathod, Vipal; Shah, Ronak; Mandge, Deepak; Parmar, Rajvi; Rao, S.L.

    2016-01-01

    Highlights: • A dedicated full scale ITER prototype Local Control Unit for ITER-India Gyrotron test facility. • National Instruments® make PXIe system for real time control & data acquisition and Siemens® PLC for sequence control function. • Hardwired FPGA based fast protection interlock system. • High speed analog fiber optical transmission link using V/F and F/V technique. • Software framework based on LabVIEW™ platform and ITER CODAC Core System. - Abstract: Electron Cyclotron system on ITER, is one of the important RF ancillary systems based on high power Gyrotron RF sources, that is used for plasma heating and current drive applications. To operate a Gyrotron source, various auxiliary systems and services such as Super Conducting Magnet set, High Voltage Power Supplies, Auxiliary Power Supplies, Waveguide components, Cooling water system and a Local Control Unit (LCU) are required. The LCU plays a very crucial role for the safe and reliable operation of Gyrotron system. A dedicated full scale ITER prototype LCU is being developed for testing and commissioning of an ITER like Test Gyrotron at ITER-India Gyrotron Test facility (IIGTF). The main functions of LCU include Sequence Control, Local Interlock Protection and Real Time Data Acquisition. PLC based slow controller is used for implementing the Sequence Control & Slow Interlock functions. Critical Protection Interlocks are required to have a response time of <10 μs and are implemented using custom built hardware and PXIe based fast controller. Also PXIe system is used for implementing Real Time Data Acquisition function that is required to have slow and fast acquisition with online visualization and off line analysis facility. A Signal Conditioning Unit (SCU) is used to interface and faithfully transmit the field signals to the remote control systems. Necessary controller hardware is procured and several pre-prototype developments have been taken up to establish the critical subsystems such as

  20. Indigenous unit for bending and twisting tests of ultra-thin films on a flexible substrate

    Science.gov (United States)

    D'souza, Slavia Deeksha; Hazarika, Pratim; Prakasarao, Ch Surya; Kovendhan, M.; Kumar, R. Arockia; Joseph, D. Paul

    2018-04-01

    An indigenous unit is designed to test the stability of thin films deposited on to a flexible substrate by inducing a required number of bending and twisting under specific conditions. The unit is designed using aluminum and automated by sending pulse width modulated signals to servo motors using ATmega328 microcontroller. We have tested the unit by imparting stress on to a commercial ITO film deposited on a PET substrate. After a definite number of bending and twisting cycles, the electrical and surface properties are studied and the results are discussed.

  1. Performance investigation of low-toxic organic corrosion inhibitors in amine treating unit

    International Nuclear Information System (INIS)

    Veawab, A.; Tanthapanichakoon, W.

    2003-01-01

    Amine treating unit is constantly subject to severe corrosion problems leading to extra expenditure and operational limitations. Heavy-metal vanadium compounds are extensively used as corrosion inhibitors to suppress the severe corrosion to an acceptable level. In recent years, the fact that these vanadium compounds are inherently toxic and can potentially pose adverse impacts on the human health and the environment has brought about environmental awareness that causes their uses costly due to the difficulty in waste disposal. To respond to the environmental concern and reduce cost of waste disposal as well as prepare for more stringent regulations for chemical uses, the development of low-toxic corrosion inhibitors is necessary. This work therefore focuses on an investigation of inhibition performance of a number of organic and inorganic compounds that have relatively low toxicity in comparison with conventional inhibitors. The performance evaluation was carried out through corrosion experiments using carbon steel specimens. The experiments were done in 3 and 5 kmol/m 3 monoethanolamine (MEA) solution saturated with CO 2 at 80 o C. It was found that several tested compounds have potential to be effective low-toxic corrosion inhibitors. The promising compounds provide reasonable and in some cases comparable protection performance to the conventional inhibitor. (author)

  2. Simulations and field tests of a reactor coolant pump emergency start-up by means of remote gas units

    International Nuclear Information System (INIS)

    Omahen, P.; Gubina, F.

    1992-01-01

    The problem of the reactor coolant pump start-up in case of emergency by means of remote gas power plant units was analyzed. In this paper a simulation model is developed which enabled a detailed simulation of the transient process occurring at the start-up. The start-up of the RCP motor set was simulated in case of available one and two gas units. The field tests were performed and the measured variable values complied well with the simulation results. Two gas units have been determined as a safe start-up scheme of the RCP motor set considering for safety reasons accepted busbars and motor protection settings. A derived model for deep rotor bars was experimentally confirmed as effective means for the RCP motor set start-up transient simulation. Start-up procedures have been designed and adopted to the safety procedures of the Nuclear Power Plant Krsko

  3. Test and performances of the RPC trigger chambers of the ATLAS experiment at LHC

    CERN Document Server

    Aielli, G; Ammosov, A; Biglietti, M; Brambilla, Elena; Camarri, P; Canale, V; Caprio, M A; Cardarelli, R; Carlino, G; Cataldi, G; Chiodini, G; Di Simone, A; Di Ciaccio, A; Della Volpe, D; De Asmundis, R; Della Pietra, M; Grancagnolo, F; Gorini, E; Iengo, P; Liberti, B; Patricelli, S; Perrino, R; Primavera, M; Santonico, R; Sehkniadze, G; Spagnolo, S; Sviridov, Yu; Zaetz, V G

    2004-01-01

    RPCs will be used as trigger detectors in the barrel region of the Muon Spectrometer of the ATLAS experiment at LHC. The total number of RPC units to be installed is 1088, covering a total surface of about 3500m**2. ATLAS RPCs work in avalanche mode with C//2H//2F //4/C//4H //1//0/SF//6 (94.7%/5%/0.3%) gas mixture. A cosmic ray test stand has been designed and built in Naples laboratories in order to carry out a complete test of the ATLAS RPC units. Since August 2002 about 300 units have been tested. A description of the test stand, test procedure and results are presented.

  4. Zinc injection during Hot Functional Test (HFT) in Tomari Unit 3

    International Nuclear Information System (INIS)

    Hayakawa, H.; Mino, Y.; Nakahama, S.; Aizawa, Y.; Nishimura, T.; Umehara, R.; Shimuz, Y.; Kogawa, N.; Ojima, Z.

    2010-01-01

    Zinc injection is performed to reduce radiation exposure around the world, and its effect is confirmed. In Japanese PWRs, the actual effect is also confirmed. Therefore, number of Japanese PWR plans, where zinc is injected, increase. We conclude that zinc injection from Hot Function Test (HFT), when RCS temperature and corrosion rate of material of primary components are increased firstly, is more effective for reducing radiation exposure, because oxide layer with zinc is more stable than with other metals such as cobalt and it is confirmed that zinc injection reduces corrosion amount of alloy 690TT in laboratory test. Therefore in Tomari Unit 3 (PWR, commercial operation from December 2009) of HOKKAIDO ELECTRIC POWER CO., INC, zinc injection was started from first Heat-up during trial operation. During HFT, zinc consumption coincides with assumed plan and Ni concentration is lower than in reference plant. Therefore we conclude that stable and fine oxide layer including zinc is formed. We hope that radiation exposure reduces because of these results. (We published at Asia Water Chemistry Symposium 2009 in NAGOYA.) Results of analysis of oxide layer on SG insert plate, removed after HFT, will be reported. Also Actual results of water chemistry and zinc injection after HFT will be reported. (author)

  5. Performance Prediction of Centrifugal Compressor for Drop-In Testing Using Low Global Warming Potential Alternative Refrigerants and Performance Test Codes

    Directory of Open Access Journals (Sweden)

    Joo Hoon Park

    2017-12-01

    Full Text Available As environmental regulations to stall global warming are strengthened around the world, studies using newly developed low global warming potential (GWP alternative refrigerants are increasing. In this study, substitute refrigerants, R-1234ze (E and R-1233zd (E, were used in the centrifugal compressor of an R-134a 2-stage centrifugal chiller with a fixed rotational speed. Performance predictions and thermodynamic analyses of the centrifugal compressor for drop-in testing were performed. A performance prediction method based on the existing ASME PTC-10 performance test code was proposed. The proposed method yielded the expected operating area and operating point of the centrifugal compressor with alternative refrigerants. The thermodynamic performance of the first and second stages of the centrifugal compressor was calculated as the polytropic state. To verify the suitability of the proposed method, the drop-in test results of the two alternative refrigerants were compared. The predicted operating range based on the permissible deviation of ASME PTC-10 confirmed that the temperature difference was very small at the same efficiency. Because the drop-in test of R-1234ze (E was performed within the expected operating range, the centrifugal compressor using R-1234ze (E is considered well predicted. However, the predictions of the operating point and operating range of R-1233zd (E were lower than those of the drop-in test. The proposed performance prediction method will assist in understanding thermodynamic performance at the expected operating point and operating area of a centrifugal compressor using alternative gases based on limited design and structure information.

  6. An Integrated Database of Unit Training Performance: Description an Lessons Learned

    National Research Council Canada - National Science Library

    Leibrecht, Bruce

    1997-01-01

    The Army Research Institute (ARI) has developed a prototype relational database for processing and archiving unit performance data from home station, training area, simulation based, and Combat Training Center training exercises...

  7. 48 CFR 225.802-70 - Contracts for performance outside the United States and Canada.

    Science.gov (United States)

    2010-10-01

    ... outside the United States and Canada. 225.802-70 Section 225.802-70 Federal Acquisition Regulations System... States and Canada. Follow the procedures at PGI 225.802-70 when placing a contract requiring performance outside the United States and Canada. Also see Subpart 225.74, Defense Contractors Outside the United...

  8. Correlation Between Screening Mammography Interpretive Performance on a Test Set and Performance in Clinical Practice.

    Science.gov (United States)

    Miglioretti, Diana L; Ichikawa, Laura; Smith, Robert A; Buist, Diana S M; Carney, Patricia A; Geller, Berta; Monsees, Barbara; Onega, Tracy; Rosenberg, Robert; Sickles, Edward A; Yankaskas, Bonnie C; Kerlikowske, Karla

    2017-10-01

    Evidence is inconsistent about whether radiologists' interpretive performance on a screening mammography test set reflects their performance in clinical practice. This study aimed to estimate the correlation between test set and clinical performance and determine if the correlation is influenced by cancer prevalence or lesion difficulty in the test set. This institutional review board-approved study randomized 83 radiologists from six Breast Cancer Surveillance Consortium registries to assess one of four test sets of 109 screening mammograms each; 48 radiologists completed a fifth test set of 110 mammograms 2 years later. Test sets differed in number of cancer cases and difficulty of lesion detection. Test set sensitivity and specificity were estimated using woman-level and breast-level recall with cancer status and expert opinion as gold standards. Clinical performance was estimated using women-level recall with cancer status as the gold standard. Spearman rank correlations between test set and clinical performance with 95% confidence intervals (CI) were estimated. For test sets with fewer cancers (N = 15) that were more difficult to detect, correlations were weak to moderate for sensitivity (woman level = 0.46, 95% CI = 0.16, 0.69; breast level = 0.35, 95% CI = 0.03, 0.61) and weak for specificity (0.24, 95% CI = 0.01, 0.45) relative to expert recall. Correlations for test sets with more cancers (N = 30) were close to 0 and not statistically significant. Correlations between screening performance on a test set and performance in clinical practice are not strong. Test set performance more accurately reflects performance in clinical practice if cancer prevalence is low and lesions are challenging to detect. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  9. Performance of HESCO Bastion Units Under Combined Normal and Cyclic Lateral Loading

    Science.gov (United States)

    2017-02-01

    4 vii Figures and Tables Figures Figure 1. HESCO bastion welded wire mesh (WWM) panels. .................................................. 3...in the testing program. The Commander of ERDC was COL Bryan S. Green and the Director was Dr. Jeffery P. Holland. ERDC/CERL TR-17-4 x Unit... welded wire mesh that is used with a geotextile liner. HESCO units are set up onsite and filled with soil or sand, as available at the construction

  10. Summary of inspection findings of licensee inservice testing programs at United States commercial nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Dunlop, A.; Colaccino, J.

    1996-12-01

    Periodic inspections of pump and valve inservice testing (IST) programs in United States commercial nuclear power plants are performed by Nuclear Regulatory Commission (NRC) Regional Inspectors to verify licensee regulatory compliance and licensee commitments. IST inspections are conducted using NRC Inspection Procedure 73756, {open_quotes}Inservice Testing of Pumps and Valves{close_quotes} (IP 73756), which was updated on July 27, 1995. A large number of IST inspections have also been conducted using Temporary Instruction 2515/114, {open_quotes}Inspection Requirements for Generic Letter 89-04, Acceptable Inservice Testing Programs{close_quotes} (TI-2515/114), which was issued January 15, 1992. A majority of U.S. commercial nuclear power plants have had an IST inspection to either IP 73756 or TI 2515/114. This paper is intended to summarize the significant and recurring findings from a number of these inspections since January of 1990.

  11. Performance of smokeless gasoline fire test facility

    International Nuclear Information System (INIS)

    Griffin, J.F.; Watkins, R.A.

    1978-01-01

    Packaging for radioactive materials must perform satisfactorily when subjected to temperatures simulating an accident involving a fire. The new thermal test facility has proved to be a reliable method for satisfactorily performing the required test. The flame provides sufficient heat to assure that the test is valid, and the temperature can be controlled satisfactorily. Also, the air and water mist systems virtually eliminate any smoke and thereby exceed the local EPA requirements. The combination of the two systems provides an inexpensive, low maintenance technique for elimination of the smoke plume

  12. Expectancy of an open-book test decreases performance on a delayed closed-book test.

    Science.gov (United States)

    Agarwal, Pooja K; Roediger, Henry L

    2011-11-01

    Two experiments examined the influence of practice with, and the expectancy of, open-book tests (students viewed studied material while taking the test) versus closed-book tests (students completed the test without viewing the studied material) on delayed retention and transfer. Using GRE materials specifically designed for open-book testing, participants studied passages and then took initial open- or closed-book tests. Open-book testing led to better initial performance than closed-book testing, but on a delayed criterial (closed-book) test both types of testing produced similar retention after a two-day delay in Experiment 1. In Experiment 2 participants were informed in advance about the type of delayed criterial test to expect (open- or closed-book). Expecting an open-book test (relative to a closed-book test) decreased participants' time spent studying and their delayed test performance on closed-book comprehension and transfer tests, demonstrating that test expectancy can influence long-term learning. Expectancy of open-book tests may impair long-term retention and transfer compared to closed-book tests, despite superior initial performance on open-book tests and students' preference for open-book tests.

  13. Enhancement on Wingate Anaerobic Test Performance With Hyperventilation.

    Science.gov (United States)

    Leithäuser, Renate M; Böning, Dieter; Hütler, Matthias; Beneke, Ralph

    2016-07-01

    Relatively long-lasting metabolic alkalizing procedures such as bicarbonate ingestion have potential for improving performance in long-sprint to middle-distance events. Within a few minutes, hyperventilation can induce respiratory alkalosis. However, corresponding performance effects are missing or equivocal at best. To test a potential performance-enhancing effect of respiratory alkalosis in a 30-s Wingate Anaerobic Test (WAnT). 10 men (mean ± SD age 26.6 ± 4.9 y, height 184.4 ± 6.1 cm, body-mass test 1 80.7 ± 7.7 kg, body-mass test 2 80.4 ± 7.2 kg, peak oxygen uptake 3.95 ± 0.43 L/min) performed 2 WAnTs, 1 with and 1 without a standardized 15-min hyperventilation program pre-WAnT in randomized order separated by 1 wk. Compared with the control condition, hyperventilation reduced (all P respiratory alkalosis can enhance WAnT cycling sprint performance well in the magnitude of what is seen after successful bicarbonate ingestion.

  14. Motivation and Test Anxiety in Test Performance across Three Testing Contexts: The CAEL, CET, and GEPT

    Science.gov (United States)

    Cheng, Liying; Klinger, Don; Fox, Janna; Doe, Christine; Jin, Yan; Wu, Jessica

    2014-01-01

    This study examined test-takers' motivation, test anxiety, and test performance across a range of social and educational contexts in three high-stakes language tests: the Canadian Academic English Language (CAEL) Assessment in Canada, the College English Test (CET) in the People's Republic of China, and the General English Proficiency Test (GEPT)…

  15. Summary of functional and performance test procedures

    DEFF Research Database (Denmark)

    Mitzel, Jens; Gülzow, Erich; Friedrich, K. Andreas

    Different Test Modules (TM) are defined for the functional and performance characterization of a PEMFC stack. The master document TM2.00 defines requirements and methodology for parameter variation, stability and data acquisition.......Different Test Modules (TM) are defined for the functional and performance characterization of a PEMFC stack. The master document TM2.00 defines requirements and methodology for parameter variation, stability and data acquisition....

  16. Inquiry commission of the consequences of atmospheric nuclear tests performed between 1966 and 1974 in French Polynesia

    International Nuclear Information System (INIS)

    2006-01-01

    After having outlined that the French Polynesia institutions want to make their own assessment of 30 years of nuclear tests, this document presents the inquiry commission set up by the French Polynesia Council, and what this commission has done. It outlines the present consequences of the nuclear tests performed in Polynesia, proposes a summary of the inquiry commission report, and formulates a set of recommendations. Appendices contain a text published by the CRIIRAD after a mission in Polynesia, a reference to an indemnification law in the United States, and a bill proposition

  17. STREAMLINED APPROACH FOR ENVIRONMENTAL RESTORATION PLAN FOR CORRECTIVE ACTION UNIT 116: AREA 25 TEST CELL C FACILITY NEVADA TEST SITE, NEVADA

    International Nuclear Information System (INIS)

    2006-01-01

    This Streamlined Approach for Environmental Restoration Plan identifies the activities required for the closure of Corrective Action Unit 116, Area 25 Test Cell C Facility. The Test Cell C Facility is located in Area 25 of the Nevada Test Site approximately 25 miles northwest of Mercury, Nevada

  18. Technical evaluation of the noise and isolation testing of the safety features actuation system at the Davis Besse Nuclear Power Station, Unit 1

    International Nuclear Information System (INIS)

    Selan, J.C.

    1981-07-01

    This report documents the technical evaluation of the noise and isolation testing of the safety features actuation system at the Davis Besse Nuclear Power Station, Unit 1. The tests were to verify that faults on the non-Class 1E circuits would not propagate to the Class 1E circuits and degrade them below acceptable levels. The tests conducted demonstrated that the safety features actuation system did not degrade below acceptable levels nor was the system's ability to perform its protective functions affected

  19. New multi-country evidence on purchasing power parity: multivariate unit root test results

    NARCIS (Netherlands)

    J.J.J. Groen (Jan)

    2000-01-01

    textabstractIn this paper a likelihood-based multivariate unit root testing framework is utilized to test whether the real exchange rates of G10 countries are non-stationary. The framework uses a likelihood ratio statistic which combines the information across all involved countries while retaining

  20. Use of the Cognitive Performance Test for Identifying Deficits in Hospitalized Older Adults

    Directory of Open Access Journals (Sweden)

    Alison Douglas

    2012-01-01

    Full Text Available Objectives. The Cognitive Performance Test (CPT is a functional assessment for persons with dementia. The study purpose was to evaluate the reliability, discriminant, and concurrent validity of the CPT. Method. The CPT was tested against other measures of cognition (Standardized Mini Mental Status Exam (SMMSE and Assessment of Motor and Process Skills-Process scale (AMPS-Process. Participants were persons 65 years and older admitted to a geriatric rehabilitation unit (n=47. Results. The CPT correlated moderately with measures of cognition (SMMSE r=0.47, AMPS-Process r=0.53, P<0.01, and ADL burden of care (FIM r=0.32, P<0.05. Scores were not affected by age, sex, years of education, motor skills, or comorbidities. The CPT differentiated between impaired and unimpaired individuals differently from other measures. Conclusion. While CPT appears related to other measures of cognition, test interpretation requires noting the variability between CPT scores and those measures.

  1. First performance results of the ALICE TPC Readout Control Unit 2

    OpenAIRE

    Zhao, Chengxin; Alme, Johan; Alt, Torsten; Appelshäuser, Harald; Bratrud, Lars Karlot Stubberud; Castro, Andrew; Costa, Filippo; David, Ernö; Gunji, Tako; Kirsch, S; Kiss, Tivadar; Langøy, Rune; Lien, Jørgen; Lippmann, C; Oskarsson, Anders

    2016-01-01

    - This paper presents the first performance results of the ALICE TPC Readout Control Unit 2 (RCU2). With the upgraded hardware typology and the new readout scheme in FPGA design, the RCU2 is designed to achieve twice the readout speed of the present Readout Control Unit. Design choices such as using the flash-based Microsemi Smartfusion2 FPGA and applying mitigation techniques in interfaces and FPGA design ensure a high degree of radiation tolerance. This paper presents the system level ir...

  2. Irradiation test and performance evaluation of DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Song, K. C.; Moon, J. S.

    2002-05-01

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  3. High School Students' Performance on Vandenberg's Mental Rotations Test: Art Ability, Gender, Activities, Academic Performance, Strategies, and Ease of Taking the Test.

    Science.gov (United States)

    Gurny, Helen Graham

    This study tested whether mental rotation performance of 186 high school students (80 males and 106 females) in grades 9 through 12 in art and nonart classes on Vandenbergs Mental Rotations test (S. Vandenberg and Kuse, 1978) was affected by gender, visual-spatial activities, strategies used while performing the test, and the ease of test taking.…

  4. Safety assessment for the proposed pilot-scale treatability tests for the 200-UP-1 and 200-ZP-1 groundwater operable units. Revision 1

    International Nuclear Information System (INIS)

    1994-12-01

    This safety assessment provides an analysis of the proposed pilot-scale treatability test activities to be and conducted within the 200 Area groundwater operable units on the Hanford Site. The 200-UP-1 and 200-ZP-1 operable units are located in the 200 West Area of the Hanford Site. These tests will evaluate an ion exchange (IX) water purification treatment system and granular activated carbon (GAC). A detailed engineering analysis of (GAC) adsorption for remediation of groundwater contamination. A detailed engineering analysis of the IX treatment system. The principal source of information for this assessment, states that the performance objective of the treatment systems is to remove 90% of the uranium and technetium-99 ( 99 Tc) from the extracted groundwater at the 200-UP-1 site. The performance objective for 200-ZP-1 is to remove 90% of the carbon tetrachloride (CCl 4 ), chloroform, and trichloroethylene (TCE) from the extracted groundwater

  5. Anonymous or confidential HIV counseling and voluntary testing in federally funded testing sites--United States, 1995-1997.

    Science.gov (United States)

    1999-06-25

    Human immunodeficiency virus (HIV) counseling and voluntary testing (CT) programs have been an important part of national HIV prevention efforts since the first HIV antibody tests became available in 1985. In 1995, these programs accounted for approximately 15% of annual HIV antibody testing in the United States, excluding testing for blood donation. CT opportunities are offered to persons at risk for HIV infection at approximately 11,000 sites, including dedicated HIV CT sites, sexually transmitted disease (STD) clinics, drug-treatment centers, hospitals, and prisons. In 39 states, testing can be obtained anonymously, where persons do not have to give their name to get tested. All states provide confidential testing (by name) and have confidentiality laws and regulations to protect this information. This report compares patterns of anonymous and confidential testing in all federally funded CT programs from 1995 through 1997 and documents the importance of both types of testing opportunities.

  6. Correlation of neonatal intensive care unit performance across multiple measures of quality of care.

    Science.gov (United States)

    Profit, Jochen; Zupancic, John A F; Gould, Jeffrey B; Pietz, Kenneth; Kowalkowski, Marc A; Draper, David; Hysong, Sylvia J; Petersen, Laura A

    2013-01-01

    To examine whether high performance on one measure of quality is associated with high performance on others and to develop a data-driven explanatory model of neonatal intensive care unit (NICU) performance. We conducted a cross-sectional data analysis of a statewide perinatal care database. Risk-adjusted NICU ranks were computed for each of 8 measures of quality selected based on expert input. Correlations across measures were tested using the Pearson correlation coefficient. Exploratory factor analysis was used to determine whether underlying factors were driving the correlations. Twenty-two regional NICUs in California. In total, 5445 very low-birth-weight infants cared for between January 1, 2004, and December 31, 2007. Pneumothorax, growth velocity, health care-associated infection, antenatal corticosteroid use, hypothermia during the first hour of life, chronic lung disease, mortality in the NICU, and discharge on any human breast milk. The NICUs varied substantially in their clinical performance across measures of quality. Of 28 unit-level correlations, 6 were significant (ρ < .05). Correlations between pairs of measures of quality of care were strong (ρ ≥ .5) for 1 pair, moderate (range, ρ ≥ .3 to ρ < .5) for 8 pairs, weak (range, ρ ≥ .1 to ρ < .3) for 5 pairs, and negligible (ρ < .1) for 14 pairs. Exploratory factor analysis revealed 4 underlying factors of quality in this sample. Pneumothorax, mortality in the NICU, and antenatal corticosteroid use loaded on factor 1; growth velocity and health care-associated infection loaded on factor 2; chronic lung disease loaded on factor 3; and discharge on any human breast milk loaded on factor 4. In this sample, the ability of individual measures of quality to explain overall quality of neonatal intensive care was modest.

  7. NNWSI waste form performance test development

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.

    1984-01-01

    A test method has been developed to measure the release of radionuclides from the waste package under simulated NNWSI repository conditions, and to provide information concerning materials interactions that may occur in the repository. Data from 13 weeks of unsaturated testing are discussed and compared to that from a 13-week analog test. The data indicate that the waste form test is capable of producing consistent, reproducible results that will be useful in evaluating the role of the waste in the long-term performance of the repository. 6 references, 3 figures

  8. Alternative Site Technology Deployment-Monitoring System for the U-3ax/bl Disposal Unit at the Nevada Test Site

    International Nuclear Information System (INIS)

    Dixon, J.M.; Levitt, D.G.; Rawlinson, S.E.

    2001-01-01

    In December 2000, a performance monitoring facility was constructed adjacent to the U-3ax/bl mixed waste disposal unit at the Nevada Test Site (NTS). Recent studies conducted in the arid southwestern United States suggest that a vegetated monolayer evapotranspiration (ET) closure cover may be more effective at isolating waste than traditional Resource Conservation and Recovery Act (RCRA) multi-layered designs. The monitoring system deployed next to the U-3ax/bl disposal unit consists of eight drainage lysimeters with three surface treatments: two are left bare; two are revegetated with native species; two are being allowed to revegetate with invader species; and two are reserved for future studies. Soil used in each lysimeter is native alluvium taken from the same location as the soil used for the cover material on U-3ax/bl. The lysimeters were constructed so that any drainage to the bottom can be collected and measured. To provide a detailed evaluation of the cover performance, an ar ray of 16 sensors was installed in each lysimeter to measure soil water content, soil water potential, and soil temperature. Revegetation of the U-3ax/bl closure cover establishes a stable plant community that maximizes water loss through transpiration while at the same time, reduces water and wind erosion and ultimately restores the disposal unit to its surrounding Great Basin Desert environment

  9. Evaluation of the diagnostic performance and operational characteristics of four rapid immunochromatographic syphilis tests in Burkina Faso.

    Science.gov (United States)

    Bocoum, Fadima Yaya; Ouédraogo, Henri; Tarnagda, Grissoum; Kiba, Alice; Tiendrebeogo, Simon; Bationo, Fabrice; Liestman, Benjamin; Diagbouga, Serge; Zarowsky, Christina; Traoré, Ramata Ouédraogo; Kouanda, Séni

    2015-06-01

    Little information is available on the rapid diagnostic testing for syphilis in Burkina Faso. The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health workers in a maternity unit. Four rapid syphilis tests commercially available in Burkina Faso were evaluated using archived serum samples and Treponema pallidum hemagglutination assay (TPHA) as the gold standard. Blood samples were collected between November 2011 and June 2012 from blood donors at the Regional Blood Transfusion Center of Ouagadougou. The sensitivity and specificity of the tests were calculated. Evaluation of operational characteristics such as clarity of pamphlet, complexity of technique, duration, was conducted in a first-level healthcare center with health workers in maternity unit. Alere DetermineTM Syphilis was the most sensitive of the four rapid syphilis tests evaluated. It was followed by SD Bioline Syphilis 3.0, Cypress Diagnostics Syphilis Quick test and Accu-Tell ® Rapid Anti-TP, which was the least sensitive. The four tests demonstrated a good diagnostic specificity for syphilis (95-98%), and healthcare workers found them easy to use. The study allowed confirming the good performance of three of four rapid syphilis tests in Burkina Faso. More research will be conducted to assess the feasibility of introducing selected rapid tests for syphilis in antenatal care services.

  10. Pilot-scale treatability test plan for the 100-HR-3 operable unit

    International Nuclear Information System (INIS)

    1994-08-01

    This document presents the treatability test plan for pilot-scale pump-and-treat testing at the 100-HR-3 Operable Unit. The test will be conducted in fulfillment of interim Milestone M-15-06E to begin pilot-scale pump-and-treat operations by August 1994. The scope of the test was determined based on the results of lab/bench-scale tests (WHC 1993a) conducted in fulfillment of Milestone M-15-06B. These milestones were established per agreement between the U.S. Department of Energy (DOE), the Washington State Department of Ecology and the U.S. Environmental Protection Agency (EPA), and documented on Hanford Federal of Ecology Facility Agreement and Consent Order Change Control Form M-15-93-02. This test plan discusses a pilot-scale pump-and-treat test for the chromium plume associated with the D Reactor portion of the 100-HR-3 Operable Unit. Data will be collected during the pilot test to assess the effectiveness, operating parameters, and resource needs of the ion exchange (IX) pump-and-treat system. The test will provide information to assess the ability to remove contaminants by extracting groundwater from wells and treating extracted groundwater using IX. Bench-scale tests were conducted previously in which chromium VI was identified as the primary contaminant of concern in the 100-D reactor plume. The DOWEX 21K trademark resin was recommended for pilot-scale testing of an IX pump-and-treat system. The bench-scale test demonstrated that the system could remove chromium VI from groundwater to concentrations less than 50 ppb. The test also identified process parameters to monitor during pilot-scale testing. Water will be re-injected into the plume using wells outside the zone of influence and upgradient of the extraction well

  11. The experimental development and performance test of the pneumatic control-rod drive for the THTR

    International Nuclear Information System (INIS)

    Lange, G.; Boehlo, D.; Heim, H.; Kleine-Tebbe, A.

    1976-01-01

    Reactor control and shutdown of the THTR is accomplished by two independent systems, the first consisting of 36 absorber rods penetrating the graphite reflector region surrounding the core, the second consisting of 42 absorber rods that insert directly into the pebble bed core. This paper describes the design development and testing of the pneumatic rod drives used for movement of the 42 core control rods. The core control rods have two functions: the first, for reactor safety purposes, provides for adequate safe shutdown of the reactor under cold conditions; the second, for operational purposes, provides for compensation of slow changes in reactivity. The safety and operational functions for each absorber rod are respectively carried out by a long-stroke-piston pneumatic drive and by a stepping-piston pneumatic drive, both of these independent, helium-driven drives being incorporated in the rod drive unit for each control rod. To study the performance of the rod drive, a complete prototype control rod and rod drive unit was built and tested under simulated reactor operational conditions. Operational experience under helium temperatures and pressures was gained and the drives were tested under stress and simulated accident conditions. The reliability of this system has been demonstrated to licensing authorities and to the customer. The programme will be completed with the commissioning tests of drives for the THTR-300 reactor. (author)

  12. Probabilistic Approaches to Examining Linguistic Features of Test Items and Their Effect on the Performance of English Language Learners

    Science.gov (United States)

    Solano-Flores, Guillermo

    2014-01-01

    This article addresses validity and fairness in the testing of English language learners (ELLs)--students in the United States who are developing English as a second language. It discusses limitations of current approaches to examining the linguistic features of items and their effect on the performance of ELL students. The article submits that…

  13. Start-up tests of Kashiwazakikariwa Nuclear Power Station Unit No.2 and No.5

    International Nuclear Information System (INIS)

    Fueki, Kensuke; Aoki, Shiro; Tanaka, Yasuhisa; Yahagi, Kimitoshi

    1991-01-01

    The Kashiwazakikariwa Nuclear Power Station Units No.5 and No.2 started commercial operation on April 10 and September 28 of 1990 respectively. As the result of the application of the First and Second LWR Improvement and Standardization Program, the plants were designed aiming at improvement of reliability, operation, and maintenance while maintaining safety. Construction of the plants took 6.5 to 7 years for completion, during which period the last 10 months were spent for the start up tests program. Start up tests were carried out under deliberate management to assure that the plants can operate safely and steadily at the prescribed operating points, and the schedules and tests item modifications adopted in Unit No.2 and No.5 were verified under the start up tests program. (author)

  14. Factors affecting the auction price of Veldram performance tested ...

    African Journals Online (AJOL)

    The popularity of these auctions for performance tested rams (89.4 % of rams sold) indicate that Veld tested rams were sought after by buyers. The sale price of 296 Veld tested Dorper rams sold between 1994 and 2001, covering seven different tests, were compared with their measured and observed performances.

  15. Final Report for the 1st Surveillance Test of the Reactor Pressure Vessel Material (Capsule 2) of Ulchin Nuclear Power Plant Unit 4

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai (and others)

    2007-04-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 1st surveillance testing was performed completely by Korea Atomic Energy Research Institute at Daejon after the capsule was transported from Ulchin site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Ulchin Unit 4 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsule 2 is 4.306E+18n/cm{sup 2}. The bias factor, the ratio of calculation/measurement, was 0.918 for the 1st testing and the calculational uncertainty,7.0% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 3.615E+18n/cm{sup 2} based on the end of 6th fuel cycle and it was predicted that the fluences of vessel inside surface at 16 and 32EFPY would reach 8.478E+18 and 1.673E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Ulchin Unit 4 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life.

  16. Final Report for the 1st Surveillance Test of the Reactor Pressure Vessel Material (CAPSULE 2) of Ulchin Nuclear Power Plant Unit 3

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai (and others)

    2006-12-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 1st surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejon after the capsule was transported from Ulchin site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Ulchin unit 3 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsule 2 is 4.674E 18n/cm{sup 2}. The bias factor, the ratio of calculation/measurement, was 0.920 for the 1st testing and the calculational uncertainty,7.0% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 3.913E 18n/cm{sup 2} based on the end of 6th fuel cycle and it was predicted that the fluences of vessel inside surface at 16 and 32EFPY would reach 9.249E 18 and 1.834E 19n/cm{sup 2} based on the current calculation. The result through this analysis for Ulchin unit 3 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life.

  17. The Relationship between Test Preparation and State Test Performance: Evidence from the Measure of Effective Teaching (MET) Project

    Science.gov (United States)

    Li, Hongli; Xiong, Yao

    2018-01-01

    The passage of the NCLB Act enhanced accountability policies in the United States, and standardized testing became prevalent as a policy tool to ensure accountability in K-12 education. Given the high stakes of state administered accountability tests, more school teachers have adopted test-preparation strategies to ensure satisfactory student…

  18. Unit-based functional IDDT testing for aging degradation monitoring in a VLIW processor

    NARCIS (Netherlands)

    Zhao, Yong; Kerkhoff, Hans G.

    2015-01-01

    In this paper, functional unit-based IDDT testing has been applied for a 90nm VLIW processor to monitor its aging degradation. This technique can provide health data for reliability evaluation as used in e.g. prognostic software for lifetime prediction. The test-program development based on the

  19. Dual Electron Spectrometer for Magnetospheric Multiscale Mission: Results of the Comprehensive Tests of the Engineering Test Unit

    Science.gov (United States)

    Avanov, Levon A.; Gliese, Ulrik; Mariano, Albert; Tucker, Corey; Barrie, Alexander; Chornay, Dennis J.; Pollock, Craig James; Kujawski, Joseph T.; Collinson, Glyn A.; Nguyen, Quang T.; hide

    2011-01-01

    The Magnetospheric Multiscale mission (MMS) is designed to study fundamental phenomena in space plasma physics such as a magnetic reconnection. The mission consists of four spacecraft, equipped with identical scientific payloads, allowing for the first measurements of fast dynamics in the critical electron diffusion region where magnetic reconnection occurs and charged particles are demagnetized. The MMS orbit is optimized to ensure the spacecraft spend extended periods of time in locations where reconnection is known to occur: at the dayside magnetopause and in the magnetotail. In order to resolve fine structures of the three dimensional electron distributions in the diffusion region (reconnection site), the Fast Plasma Investigation's (FPI) Dual Electron Spectrometer (DES) is designed to measure three dimensional electron velocity distributions with an extremely high time resolution of 30 ms. In order to achieve this unprecedented sampling rate, four dual spectrometers, each sampling 180 x 45 degree sections of the sky, are installed on each spacecraft. We present results of the comprehensive tests performed on the DES Engineering & Test Unit (ETU). This includes main parameters of the spectrometer such as energy resolution, angular acceptance, and geometric factor along with their variations over the 16 pixels spanning the 180-degree tophat Electro Static Analyzer (ESA) field of view and over the energy of the test beam. A newly developed method for precisely defining the operational space of the instrument is presented as well. This allows optimization of the trade-off between pixel to pixel crosstalk and uniformity of the main spectrometer parameters.

  20. Nuclear Facility Accident (NFAC) Unit Test Report For HPAC Version 6.3

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ronald W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Computational Sciences and Engineering Division; Morris, Robert W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Computational Sciences and Engineering Division; Sulfredge, Charles David [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Computational Sciences and Engineering Division

    2015-12-01

    This is a unit test report for the Nuclear Facility Accident (NFAC) model for the Hazard Prediction and Assessment Capability (HPAC) version 6.3. NFAC’s responsibility as an HPAC component is three-fold. First, it must present an interactive graphical user interface (GUI) by which users can view and edit the definition of an NFAC incident. Second, for each incident defined, NFAC must interact with RTH to create activity table inputs and associate them with pseudo materials to be transported via SCIPUFF. Third, NFAC must create SCIPUFF releases with the associated pseudo materials for transport and dispersion. The goal of NFAC unit testing is to verify that the inputs it produces are correct for the source term or model definition as specified by the user via the GUI.

  1. Nuclear Facility Accident (NFAC) Unit Test Report For HPAC Version 6.3

    International Nuclear Information System (INIS)

    Lee, Ronald W.; Morris, Robert W.; Sulfredge, Charles David

    2015-01-01

    This is a unit test report for the Nuclear Facility Accident (NFAC) model for the Hazard Prediction and Assessment Capability (HPAC) version 6.3. NFAC's responsibility as an HPAC component is three-fold. First, it must present an interactive graphical user interface (GUI) by which users can view and edit the definition of an NFAC incident. Second, for each incident defined, NFAC must interact with RTH to create activity table inputs and associate them with pseudo materials to be transported via SCIPUFF. Third, NFAC must create SCIPUFF releases with the associated pseudo materials for transport and dispersion. The goal of NFAC unit testing is to verify that the inputs it produces are correct for the source term or model definition as specified by the user via the GUI.

  2. Draft plan for the Waste Isolation Pilot Plant test phase: Performance assessment and operations demonstration

    International Nuclear Information System (INIS)

    1989-04-01

    The mission of the Waste Isolation Pilot Plant (WIPP) Project is to provide a research and development facility to demonstrate the safe disposal of transuranic (TRU) radioactive wastes resulting from United States defense programs. With the Construction Phase of the WIPP facility nearing completion, WIPP is ready to initiate the next phase in its development, the Test Phase. The purpose of the Test Phase is to collect the necessary scientific and operational data to support a determination whether to proceed to the Disposal Phase and thereby designate WIPP a demonstration facility for the disposal of TRU wastes. This decision to proceed to the Disposal Phase is scheduled for consideration by September 1994. Development of the WIPP facility is the responsibility of the United States Department of Energy (DOE), whose Albuquerque Operations Office has designated the WIPP Project Office as Project Manager. This document describes the two major programs to be conducted during the Test Phase of WIPP: (1) Performance Assessment for determination of compliance with the Environmental Protection Agency Standard and (2) Operations Demonstration for evaluation of the safety and effectiveness of the DOE TRU waste management system's ability to emplace design throughput quantities of TRU waste in the WIPP facility. 42 refs., 38 figs., 14 tabs

  3. Beam test performance of the SKIROC2 ASIC

    CERN Document Server

    Frisson, T; Anduze, M; Augustin, J.E; Bonis, J; Boudry, V; Bourgeois, C; Brient, J.C; Callier, S; Cerutti, M; Chen, S; Cornat, R; Cornebise, P; Cuisy, D; David, J; De la Taille, C; Dulucq, F; Frotin, M; Gastaldi, F; Ghislain, P; Giraud, J; Gonnin, A; Grondin, D; Guliyev, E; Hostachy, J.Y; Jeans, D; Kamiya, Y; Kawagoe, K; Kozakai, C; Lacour, D; Lavergne, L; Lee, S.H; Magniette, F; Ono, H; Poeschl, R; Rouëné, J; Seguin-Moreau, N; Song, H.S; Sudo, Y; Thiebault, A; Tran, H; Ueno, H; Van der Kolk, N; Yoshioka, T

    2015-01-01

    Beam tests of the first layers of CALICE silicon tungsten ECAL technological prototype were performed in April and July 2012 using 1–6 GeV electron beam at DESY. This paper presents an analysis of the SKIROC2 readout ASIC performance under test beam conditions.

  4. 40 CFR 63.309 - Performance tests and procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Performance tests and procedures. 63.309 Section 63.309 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Standards for Coke Oven Batteries § 63.309 Performance tests and procedures. (a) Except as otherwise...

  5. Towards Smart Buildings Performance Testing as a Service

    DEFF Research Database (Denmark)

    Markoska, Elena; Lazarova-Molnar, Sanja

    2018-01-01

    to buildings’ energy consumption. In this paper we propose a methodology for continuous performance testing of smart buildings as a service. We discuss the automatic discovery and instantiation of performance tests, as well as usage of results for discovery of potential faults and ways to improve buldings...

  6. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    We identify one potential source of bias that influences children’s performance on standardized tests and that is predictable based on psychological theory: the time at which students take the test. Using test data for all children attending Danish public schools between school years 2009....../10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus......, as the day wears on, students become increasingly fatigued and consequently more likely to underperform on a standardized test....

  7. Cooling tower performance improvements for a cycling PC-fired unit

    International Nuclear Information System (INIS)

    Keckritz, M.; Thelen, A.

    1997-01-01

    The inevitable deregulation of the electric utility industry has caused many electric utility companies to look closely at their existing assets and predict what role these units will play in the future. Reducing a unit's production cost is the best way to prepare for the deregulated market but this benefit often comes with an associated capital expenditure. Spending capital dollars today can pose a quandary for an investor-owned utility committed to maintaining low consumer rates. The dilemma is: How does a utility improve its competitiveness position today while ensuring that the shareholders are getting a fair return on their investment when any fuel savings are passed through to the consumer? Illinois Power (IP) has been aggressively looking to improve their current competitive position while facing the current regulatory challenges. Studies have been commissioned to identify the most attractive cost reduction opportunities available. One study identified that improving the performance of the Unit 6 cooling tower at the Havana Station would be a very economically attractive option. This paper addresses the economics of refurbishing a cooling tower for a cycling pulverized-coal (PC) unit to provide a competitive advantage leading into the deregulated electricity market

  8. Fission Surface Power Technology Demonstration Unit Test Results

    Science.gov (United States)

    Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M.; Sanzi, James L.

    2016-01-01

    The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7 percent resulting in a net system power of 8.1 kW and a system level efficiency of 17.2 percent. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to the NASA Glenn Research Center (GRC). The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3 percent. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 percent.

  9. Post-test analysis for the APR1400 LBLOCA DVI performance test using MARS

    International Nuclear Information System (INIS)

    Bae, Kyoo Hwan; Lee, Y. J.; Kim, H. C.; Bae, Y. Y.; Park, J. K.; Lee, W.

    2002-03-01

    Post-test analyses using a multi-dimensional best-estimate analysis code, MARS, are performed for the APR1400 LBLOCA DVI (Direct Vessel Injection) performance tests. This report describes the code evaluation results for the test data of various void height tests and direct bypass tests that have been performed at MIDAS test facility. MIDAS is a scaled test facility of APR1400 with the objective of identifying multi-dimensional thermal-hydraulic phenomena in the downcomer during the reflood conditions of a large break LOCA. A modified linear scale ratio was applied in its construction and test conditions. The major thermal-hydraulic parameters such as ECC bypass fraction, steam condensation fraction, and temperature distributions in downcomer are compared and evaluated. The evaluation results of MARS code for the various test cases show that: (a) MARS code has an advanced modeling capability of well predicting major multi-dimensional thermal-hydraulic phenomena occurring in the downcomer, (b) MARS code under-predicts the steam condensation rates, which in turn causes to over-predict the ECC bypass rates. However, the trend of decrease in steam condensation rate and increase in ECC bypass rate in accordance with the increase in steam flow rate, and the calculation results of the ECC bypass rates under the EM analysis conditions generally agree with the test data

  10. Exploration of task performance tests in a physics laboratory

    Science.gov (United States)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  11. Clinical performance of a new point-of-care cardiac troponin I test.

    Science.gov (United States)

    Christ, Michael; Geier, Felicitas; Blaschke, Sabine; Giannitsis, Evangelos; Khellaf, Mehdi; Mair, Johannes; Pariente, David; Scharnhorst, Volkher; Semjonow, Veronique; Hausfater, Pierre

    2018-04-09

    We evaluated the clinical performance of the Minicare cardiac troponin-I (cTnI), a new point-of-care (POC) cTnI test for the diagnosis of acute myocardial infarction (AMI) in a prospective, multicentre study (ISRCTN77371338). Of 474 patients (≥18 years) admitted to an emergency department (ED) or chest pain unit (CPU) with symptoms suggestive of acute coronary syndrome (ACS; ≤12 h from symptom onset), 465 were eligible. Minicare cTnI was tested immediately, 3 h and 6 h after presentation. AMI diagnoses were adjudicated independently based on current guidelines. The diagnostic performance of the Minicare cTnI test at 3 h was similar for whole blood and in plasma: sensitivity 0.92 vs. 0.90; specificity 0.91 vs. 0.90; positive predictive value (PPV) 0.68 vs. 0.66; negative predictive value (NPV) 0.98 vs. 0.98; positive likelihood ratio (LR+) 10.18 vs. 9.41; negative likelihood ratio (LR-) 0.09 vs. 0.11. The optimal diagnostic performance was obtained at 3 h using cut-offs cTnI >43 ng/L plus cTnI change from admission ≥18.5 ng/L: sensitivity 0.90, specificity 0.96, PPV 0.81, NPV 0.98, and LR+ 21.54. The area under the receiver operating characteristics (ROC) curve for cTnI whole blood baseline value and absolute change after 3 h curve was 0.93. These data support the clinical usefulness of Minicare cTnI within a 0 h/3 h-blood sampling protocol supported by current guidelines for the evaluation of suspected ACS.

  12. Test Format and the Variation of Gender Achievement Gaps within the United States

    Science.gov (United States)

    Reardon, Sean; Fahle, Erin; Kalogrides, Demetra; Podolsky, Anne; Zarate, Rosalia

    2016-01-01

    Prior research demonstrates the existence of gender achievement gaps and the variation in the magnitude of these gaps across states. This paper characterizes the extent to which the variation of gender achievement gaps on standardized tests across the United States can be explained by differing state accountability test formats. A comprehensive…

  13. Radon removal equipment based on aeration: A literature study of tests performed in Sweden between 1981 and 1996

    International Nuclear Information System (INIS)

    Mjoenes, L.

    2000-02-01

    In Sweden some principles to reduce the radon concentration in drinking water were tested in the beginning of the 1980s. Spray aeration under atmospheric pressure, diffused bubble aeration, aeration in the pressure tank and different combinations of these principles were studied. Aeration in the drill hole and adsorption on granulated activated char-coal were also tested. The best results, about 70 % reduction, were obtained with aeration in the pressure tank with a spray system combined with diffused air bubbling. The Oerebro project in the beginning of the 1990s included on site testing of five different aeration solutions: Aeration in the drill hole, aeration in the storage tank, ejector aeration, shallow tray aeration and packed column aeration. The radon removal efficiency varied between 20 % and 99 %. In 1994 a study intended to test the radon removal capacity of different water treatment equipment was performed. Six units of radon separators were included but most of the tested equipment was installed for other water treatment purposes. The performed measurements showed that the only types of equipment that reduce the radon concentration efficiently are radon separators and reverse osmosis filters. The radon removal capacity of the radon separators varied between 23 % and 97 %. In 1996 the nine most common radon separators on the Swedish market were tested. The results showed that the tested radon removal equipment worked well, although the technical quality and chosen technical solutions were not always the best. The radon removal capacity of the units participating in this test was in most cases between 96 and 99 %. In some cases the capacity exceeded 99 %. In order to reach this radon removal capacity the water must be recirculated in a storage tank under atmospheric pressure

  14. Radon removal equipment based on aeration: A literature study of tests performed in Sweden between 1981 and 1996

    Energy Technology Data Exchange (ETDEWEB)

    Mjoenes, L

    2000-02-01

    In Sweden some principles to reduce the radon concentration in drinking water were tested in the beginning of the 1980s. Spray aeration under atmospheric pressure, diffused bubble aeration, aeration in the pressure tank and different combinations of these principles were studied. Aeration in the drill hole and adsorption on granulated activated char-coal were also tested. The best results, about 70 % reduction, were obtained with aeration in the pressure tank with a spray system combined with diffused air bubbling. The Oerebro project in the beginning of the 1990s included on site testing of five different aeration solutions: Aeration in the drill hole, aeration in the storage tank, ejector aeration, shallow tray aeration and packed column aeration. The radon removal efficiency varied between 20 % and 99 %. In 1994 a study intended to test the radon removal capacity of different water treatment equipment was performed. Six units of radon separators were included but most of the tested equipment was installed for other water treatment purposes. The performed measurements showed that the only types of equipment that reduce the radon concentration efficiently are radon separators and reverse osmosis filters. The radon removal capacity of the radon separators varied between 23 % and 97 %. In 1996 the nine most common radon separators on the Swedish market were tested. The results showed that the tested radon removal equipment worked well, although the technical quality and chosen technical solutions were not always the best. The radon removal capacity of the units participating in this test was in most cases between 96 and 99 %. In some cases the capacity exceeded 99 %. In order to reach this radon removal capacity the water must be recirculated in a storage tank under atmospheric pressure.

  15. 78 FR 38411 - Vogtle Electric Generating Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria

    Science.gov (United States)

    2013-06-26

    ... Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) staff has determined that the inspections, tests...

  16. Design and Performance of Energy Conversion Units of Betavoltaic Isotopic Batteries

    International Nuclear Information System (INIS)

    Wang Guanquan; Yang Yuqing; Zhang Huaming; Hu Rui; Wei Hongyuan; Xiong Xiaoling; Luo Shunzhong

    2010-01-01

    Based on the single crystal silicon semiconductor junction devices, the relationships between their configurable parameters and the electrical properties were discussed for the purpose of design of energy conversion units of betavoltaic isotopic batteries. Two kinds of silicon semiconductor junction devices as energy conversion units of betavoltaic batteries were designed and customized. The electrical output properties of the devices irradiated by 63 Ni source were measured. The results show that the new designed devices perform better than the existing commercial one in open-circuit voltage, output power and energy conversion efficiency. (authors)

  17. Testing the Birth Unit Design Spatial Evaluation Tool (BUDSET) in Australia: a pilot study.

    Science.gov (United States)

    Foureur, Maralyn J; Leap, Nicky; Davis, Deborah L; Forbes, Ian F; Homer, Caroline E S

    2011-01-01

    To pilot test the Birth Unit Design Spatial Evaluation Tool (BUDSET) in an Australian maternity care setting to determine whether such an instrument can measure the optimality of different birth settings. Optimally designed spaces to give birth are likely to influence a woman's ability to experience physiologically normal labor and birth. This is important in the current industrialized environment, where increased caesarean section rates are causing concerns. The measurement of an optimal birth space is currently impossible, because there are limited tools available. A quantitative study was undertaken to pilot test the discriminant ability of the BUDSET in eight maternity units in New South Wales, Australia. Five auditors trained in the use of the BUDSET assessed the birth units using the BUDSET, which is based on 18 design principles and is divided into four domains (Fear Cascade, Facility, Aesthetics, and Support) with three to eight assessable items in each. Data were independently collected in eight birth units. Values for each of the domains were aggregated to provide an overall Optimality Score for each birth unit. A range of Optimality Scores was derived for each of the birth units (from 51 to 77 out of a possible 100 points). The BUDSET identified units with low-scoring domains. Essentially these were older units and conventional labor ward settings. The BUDSET provides a way to assess the optimality of birth units and determine which domain areas may need improvement. There is potential for improvements to existing birth spaces, and considerable improvement can be made with simple low-cost modifications. Further research is needed to validate the tool.

  18. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Science.gov (United States)

    2010-07-01

    ... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous emission...

  19. The Linkage Between Work Unit Performance Perceptions of U.S. Federal Employees and Their Job Satisfaction: An Expectancy Theory

    Directory of Open Access Journals (Sweden)

    Soyoung PARK

    2018-02-01

    Full Text Available Public organizations are interested in how to improve their performance. Performance in a work unit can also influence employee job satisfaction due to positive expectations based on higher performance. Thus, our study attempts to investigate if organizational performance has an impact on employee motivation under the premise that employees who perform better in a work unit expect greater professional recognition and rewards. By using data from the 2013 Federal Employee Viewpoint Survey (FEVS, we find that employees who perceive higher levels of performance in a work unit have a higher level of job satisfaction. This paper further shows that performance perception based on rewards is also positively related to job satisfaction.However, underrepresented groups (female and non-white, older employees and mid-level (work experience from 6 to 14 years employees are less satisfied with higher work unit performance. Finally, employees in the distributive agency category are more satisfied with work unit performance while those in the regulatory agency category are less satisfied with work unit performance. In conclusion, organizations should recognize particular characteristics of employees to develop the policies related to performance management, and effectively utilize these policies in order to attract and retain proficient workers.

  20. Model tests on dynamic performance of RC shear walls

    International Nuclear Information System (INIS)

    Nagashima, Toshio; Shibata, Akenori; Inoue, Norio; Muroi, Kazuo.

    1991-01-01

    For the inelastic dynamic response analysis of a reactor building subjected to earthquakes, it is essentially important to properly evaluate its restoring force characteristics under dynamic loading condition and its damping performance. Reinforced concrete shear walls are the main structural members of a reactor building, and dominate its seismic behavior. In order to obtain the basic information on the dynamic restoring force characteristics and damping performance of shear walls, the dynamic test using a large shaking table, static displacement control test and the pseudo-dynamic test on the models of a shear wall were conducted. In the dynamic test, four specimens were tested on a large shaking table. In the static test, four specimens were tested, and in the pseudo-dynamic test, three specimens were tested. These tests are outlined. The results of these tests were compared, placing emphasis on the restoring force characteristics and damping performance of the RC wall models. The strength was higher in the dynamic test models than in the static test models mainly due to the effect of loading rate. (K.I.)

  1. Absolute Navigation Performance of the Orion Exploration Fight Test 1

    Science.gov (United States)

    Zanetti, Renato; Holt, Greg; Gay, Robert; D'Souza, Christopher; Sud, Jastesh

    2016-01-01

    Launched in December 2014 atop a Delta IV Heavy from the Kennedy Space Center, the Orion vehicle's Exploration Flight Test-1 (EFT-1) successfully completed the objective to stress the system by placing the un-crewed vehicle on a high-energy parabolic trajectory replicating conditions similar to those that would be experienced when returning from an asteroid or a lunar mission. Unique challenges associated with designing the navigation system for EFT-1 are presented with an emphasis on how redundancy and robustness influenced the architecture. Two Inertial Measurement Units (IMUs), one GPS receiver and three barometric altimeters (BALTs) comprise the navigation sensor suite. The sensor data is multiplexed using conventional integration techniques and the state estimate is refined by the GPS pseudorange and deltarange measurements in an Extended Kalman Filter (EKF) that employs UDU factorization. The performance of the navigation system during flight is presented to substantiate the design.

  2. Development of high-performance and low-noise axial-flow fan units in their local operating region

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Seung; Ha, Min Ho; Cheong, Cheol Ung [Pusan National University, Busan (Korea, Republic of); Kim, Tae Hoon [LG Electronics Inc., Changwon (Korea, Republic of)

    2015-09-15

    Aerodynamic and aeroacoustic performances of an axial-flow fan unit are improved by modifying its housing structure without changing the fan blade. The target axial-flow fan system is used to lower temperature of a compressor and a condenser in the machine room of a household refrigerator which has relatively high system resistance due to complex layout of structures inside it. First, the performance of the fan system is experimentally characterized by measuring its volume flow rate versus static pressure using a fan performance tester satisfying the AMCA (Air Movement and Control Association) regulation, AMCA 210-07. The detailed structure of flow driven by the fan is numerically investigated using a virtual fan performance tester based on computational fluid dynamics techniques. The prediction result reveals possible loss due to radial and tangential velocity components in the wake flow downstream of the fan. The length of the fan housing is chosen as a design parameter for improving the aerodynamic and aeroacoustic performances of the fan unit by reducing the identified radial and tangential velocity components. Three fan units with different housing lengths longer than the original are analyzed using the virtual fan performance tester. The results confirm the improved aerodynamic performance of the proposed three designs. The flow field driven by the proposed fan unit is closely examined to find the causes for the observed performance improvements, which ensures that the radial and tangential velocity components in the wake flow are reduced. Finally, the improved performance of the proposed fan systems is validated by comparing the P-Q and efficiency curves measured using the fan performance tester. The noise emission from the household refrigerator is also found to be lessened when the new fan units are installed.

  3. Modified performance test of vented lead acid batteries for stationary applications

    International Nuclear Information System (INIS)

    Uhlir, K.W.; Fletcher, R.J.

    1995-01-01

    The concept of a modified performance test for vented lead acid batteries in stationary applications has been developed by the IEEE Battery Working Group. The modified performance test is defined as a test in the ''as found'' condition of the battery capacity and its ability to provide a high rate, short duration load (usually the highest rate of the duty cycle) that will confirm the battery's ability to meet the critical period of the load duty cycle, in addition to determining its percentage of rated capacity. This paper will begin by reviewing performance and service test requirements and concerns associated with both types of tests. The paper will then discuss the rationale for developing a modified performance test along with the benefits that can be derived from performing a modified performance test in lieu of a capacity test and/or a service test. The paper will conclude with an example on how to apply a modified performance test and test acceptance criteria

  4. An outlier robust unit root test with an application to the extended Nelson-Plosser data

    NARCIS (Netherlands)

    Lucas, André

    1995-01-01

    This paper considers unit root tests based on robust estimators with a high breakdown point and high efficiency. The asymptotic distribution of these tests is derived. Critical values for the test are obtained via simulation. It is found that the size of the classical OLS based Dickey-Fuller test

  5. Performance report for Stanford/SLAC Microstore Analog Memory Unit

    International Nuclear Information System (INIS)

    Freytag, D.R.; Walker, J.T.

    1984-09-01

    Tests of a newly developed Analog Memory Unit (AMU) are described. The device contains 256 analog storage cells consisting of pass transistors, a storage capacitor and a differential read out buffer. By addressing the storage cells sequentially, the shape of the signal present at the input can be recorded in time. Fast response and good amplitude resolution were the design goals for the development. Measurements on individual devices will be presented and the status of hybridized subsystems containing eight AMUs discussed

  6. Elaboration of leadership and culture in high-performing nursing units of hospitals as perceived by staff nurses.

    Science.gov (United States)

    Casida, Jesus M; Crane, Patrick C; Walker, Tara L; Wargo, Lisa M

    2012-01-01

    The leadership-culture phenomenon, a known explanatory construct for organizational performance, is understudied in nursing. Building on our previous work, we further addressed this knowledge gap through explorations of demographics and hospital variables which may have a significant influence on staff nurses' (SNs) perceptions of their nurse managers' (NMs) leadership and nursing unit culture. Furthermore, we explored the extent to which the NMs' leadership predicted specific cultures which typify nursing unit effectiveness. Using dissertation data provided by278 SNs, we found that SNs educated at the baccalaureate level or higher had favorable perceptions of their nursing unit performance and viewed their NMs' leadership differently than the SNs with diploma or associate degrees. The frequent portrayals of transformational (TFL) leadership behaviors (e.g., visionary) by the NMs were paramount in shaping culture traits which exemplify high performance outcomes. TFL leaders were more likely to shape unit cultures which are flexible and adaptive to the environmental challenges within and outside the nursing unit. Thus, the type of NMs' leadership and unit culture may provide an added value in explaining the performance level in patient care units which consequently affects the overall hospital/organizational outcomes. Implications for research and leadership practices are presented.

  7. Performance test of solar-assisted ejector cooling system

    KAUST Repository

    Huang, Bin-Juine

    2014-03-01

    A solar-assisted ejector cooling/heating system (SACH-2k) is built and test result is reported. The solar-driven ejector cooling system (ECS) is connected in series with an inverter-type air conditioner (IAC). Several advanced technologies are developed in SACH-k2, including generator liquid level control in ECS, the ECS evaporator temperature control, and optimal control of fan power in cooling tower of ECS. From the field test results, the generator liquid level control performs quite well and keeps stable performance of ejector. The ECS evaporator temperature control also performs satisfactorily to keep ejector performance normally under low or fluctuating solar radiation. The fan power control system cooling tower performs stably and reduces the power consumption dramatically without affecting the ECS performance. The test results show that the overall system COPo including power consumptions of peripheral increases from 2.94-3.3 (IAC alone) to 4.06-4.5 (SACH-k2), about 33-43%. The highest COPo is 4.5. © 2013 Elsevier Ltd and IIR. All rights reserved.

  8. Underground Test Area (UGTA) Closure Report for Corrective Action Unit 98: Frenchman Flat Nevada National Security Site, Nevada, Revision 1 ROTC-1

    International Nuclear Information System (INIS)

    Farnham, Irene

    2016-01-01

    This Closure Report (CR) has been prepared for Corrective Action Unit (CAU) 98, Frenchman Flat, Nevada National Security Site (NNSS), Nevada. The Frenchman Flat CAU was the site of 10 underground nuclear tests, some of which have impacted groundwater near the tests. This work was performed as part of the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) Activity in accordance with the Federal Facility Agreement and Consent Order (FFACO). This CR describes the selected corrective action to be implemented during closure to protect human health and the environment from the impacted groundwater

  9. Underground Test Area (UGTA) Closure Report for Corrective Action Unit 98: Frenchman Flat Nevada National Security Site, Nevada, Revision 1 ROTC-1

    Energy Technology Data Exchange (ETDEWEB)

    Farnham, Irene [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States)

    2016-08-01

    This Closure Report (CR) has been prepared for Corrective Action Unit (CAU) 98, Frenchman Flat, Nevada National Security Site (NNSS), Nevada. The Frenchman Flat CAU was the site of 10 underground nuclear tests, some of which have impacted groundwater near the tests. This work was performed as part of the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) Activity in accordance with the Federal Facility Agreement and Consent Order (FFACO). This CR describes the selected corrective action to be implemented during closure to protect human health and the environment from the impacted groundwater

  10. The Performance test of Mechanical Sodium Pump with Water Environment

    International Nuclear Information System (INIS)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Jeong, Ji-Young; Kim, Jong-Bum; Ko, Bock Seong; Park, Sang Jun; Lee, Yoon Sang

    2015-01-01

    As contrasted with PWR(Pressurized light Water Reactor) using water as a coolant, sodium is used as a coolant in SFR because of its low melting temperature, high thermal conductivity, the high boiling temperature allowing the reactors to operate at ambient pressure, and low neutron absorption cross section which is required to achieve a high neutron flux. But, sodium is violently reactive with water or oxygen like the other alkali metal. So Very strict requirements are demanded to design and fabricate of sodium experimental facilities. Furthermore, performance testing in high temperature sodium environments is more expensive and time consuming and need an extra precautions because operating and maintaining of sodium experimental facilities are very difficult. The present paper describes performance test results of mechanical sodium pump with water which has been performed with some design changes using water test facility in SAM JIN Industrial Co. To compare the hydraulic characteristic of model pump with water and sodium, the performance test of model pump were performed using vender's experimental facility for mechanical sodium pump. To accommodate non-uniform thermal expansion and to secure the operability and the safety, the gap size of some parts of original model pump was modified. Performance tests of modified mechanical sodium pump with water were successfully performed. Water is therefore often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Normal practice to thoroughly test a design or component before applied or installed in reactor is important to ensure the safety and operability in the sodium-cooled fast reactor (SFR). So, in order to estimate the hydraulic behavior of the PHTS pump of DSFR (600 MWe Demonstraion SFR), the performance tests of the model pump such as performance

  11. Eberline Alpha 7L Test Report

    CERN Document Server

    Chiaro, P J

    2002-01-01

    An Eberline continuous alpha air monitor model Alpha 7L was evaluated at Oak Ridge National Laboratory (ORNL) using the capabilities available at the Environmental Effects Laboratory (EELab). A series of tests were performed to ensure that procured units meet the requirements of the purchasing facility, Los Alamos National Laboratory (LANL). In addition to reporting on the results of each test, other activities were performed to reduce discovered susceptibilities. The parameters monitored during the tests typically included the airflow rate and/or net sup 2 sup 3 sup 9 Pu concentration values (pCi/liter). In addition, the spectrum display and operational status were monitored. Follow up tests were also performed on two LANL-provided production units. The results of those tests are at the end of this report.

  12. Carbohydrate ingestion improves performance of a new reliable test of soccer performance.

    Science.gov (United States)

    Currell, Kevin; Conway, Steve; Jeukendrup, Asker E

    2009-02-01

    The aim of the study was to investigate the reliability of a new test of soccer performance and evaluate the effect of carbohydrate (CHO) on soccer performance. Eleven university footballers were recruited and underwent 3 trials in a randomized order. Two of the trials involved ingesting a placebo beverage, and the other, a 7.5% maltodextrin solution. The protocol comprised a series of ten 6-min exercise blocks on an outdoor Astroturf pitch, separated by the performance of 2 of the 4 soccer-specific tests, making the protocol 90 min in duration. The intensity of the exercise was designed to be similar to the typical activity pattern during soccer match play. Participants performed skill tests of dribbling, agility, heading, and shooting throughout the protocol. The coefficients of variation for dribbling, agility, heading, and shooting were 2.2%, 1.2%, 7.0%, and 2.8%, respectively. The mean combined placebo scores were 42.4 +/- 2.7 s, 43.1 +/- 3.7 s, 210 +/- 34 cm, and 212 +/- 17 points for agility, dribbling, heading, and kicking, respectively. CHO ingestion led to a combined agility time of 41.5 +/- 0.8 s, for dribbling 41.7 +/- 3.5 s, 213 +/- 11 cm for heading, and 220 +/- 5 points for kicking accuracy. There was a significant improvement in performance for dribbling, agility, and shooting (p soccer performance, and ingesting CHO leads to an improvement in soccer performance.

  13. Performance of indigenously fabricated pyramid type solar desalination unit at Nawabshah

    International Nuclear Information System (INIS)

    Memon, A.H.; Rajpar, A.H.; Memon, N.A.

    2010-01-01

    The performance of locally fabricated pyramid type solar desalination unit was studied and compared with the conventional basin type solar still. Both stills were initially filled with same quantity of brackish water. Their performance was studied in terms of the quality of water produced, quantity of water desalinated per hour and total quantity of water desalinated per day during the time under study. The experiments were conducted and various parameters were recorded from 9-15 hours daily. These results showed that pyramid solar still produced 20% higher desalinated water as compared to the conventional double slope basin type solar still. This study showed that the productivity rate of soar still is dependent upon geometrical configuration of solar still. It was observed that the units can highly reduce the salinity, TDS (Total Dissolved Solids) and EC (Electrical Conductivity) of the saline ground water providing the availability of safe drinking water. (author)

  14. Integrated test plan for the field demonstration of the supported liquid membrane unit

    International Nuclear Information System (INIS)

    Dunks, K.L.; Hodgson, K.M.

    1995-06-01

    This Integrated Test Plan describes the operation and testing of a hybrid reverse osmosis (RO)/coupled transport (CT) groundwater remediation test unit, also referred to as the Environmental Restoration Technology Demonstrations at the Hanford Site. The SLM will be used to remove uranium, technetium-99, and nitrate from a selected groundwater source at the Hanford Site. The overall purpose of this test is to determine the efficiency of the RO/CT membranes operating in a hybrid unit, the ease of operating and maintaining the SLM, and the amount of secondary waste generated as a result of processing. The goal of the SLM is to develop a RO/CT process that will be applicable for removing contaminants from almost any contaminated water. This includes the effluents generated as part of the day-to-day operation of most any US Department of Energy (DOE) site. The removal of contaminants from the groundwaters before they reach the Columbia River or offsite extraction wells will reduce the risk that the population will be exposed to these compounds and will reduce the cost of subsequent groundwater cleanup

  15. Acoustic monitoring systems tests at Indian Point Unit 1. Final report

    International Nuclear Information System (INIS)

    Smith, J.R.; Rao, G.V.; Craig, J.

    1979-12-01

    This report describes the results of a program to test acoustic monitoring systems on Indian Point Unit No. 1 under actual plant operating conditions, less the reactor core. The two types of systems evaluated were the monitoring of acoustic emissions generated by growing flaws and the monitoring of acoustic signals from leaks

  16. DEVELOPING an ENGLISH PERFORMANCE TEST for INCOMING INDONESIAN COLLEGE STUDENTS

    Directory of Open Access Journals (Sweden)

    Bill Glenny Wullur

    2011-07-01

    Full Text Available Abstracts This study constructed, developed and validated an English Performance test as a complementary to an existing placement test in Universitas Klabat, Manado, Indonesia.  It is designed to provide a valid criterion-based measurement within the placement programs of the said university. The study aimed to answer the following questions: (1 What test tasks and items are needed in a performance test based on current language testing theory? (2 Is the performance test valid? (3 Is the scoring of the performance test reliable? (4 Is the performance test practical and predictive? And (5 What are the ratings of the resultant performance test? The steps in developing a performance test involved conducting needs analysis, establishing attributes of good performance test, and constructing test specification based on current language testing theory.  The speech event chosen which would generate language use was applying for financial assistance.  From this speech event, four activities were elicited: (1 writing a letter of inquiry, (2 completing an application form, (3 making an appointment for interview, (4 giving an oral presentation/interview.  These activities represent the four authentic tasks in which the desirable modes/channel of communication, language functions and skills, genre, and topic are integrated. The developed test is divided into four sections corresponding with the elicited tasks: (1 Formal letter, (2 Application form, (3 Making Appointment, and (4 Oral Presentation. The test was validated in several ways: (1 face validation compared the scores of Indonesian studying in the Philippines and in Indonesia, and found that the scores are highly correlated at Spearman ρ = .85.  (2 The content validation relied on the evaluation of expert informants.  The finding shows that the content coverage and relevance of the test is highly satisfactory. (3 The concurrent validation was conducted to the existing placement test and found

  17. Performance tests for integral reactor nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Dong-Seong; Yim, Jeong-Sik; Lee, Chong-Tak; Kim, Han-Soo; Koo, Yang-Hyun; Lee, Byung-Ho; Cheon, Jin-Sik; Oh, Je-Yong

    2006-02-15

    An integral type reactor SMART plans to utilize metallic Zr-U fuel which is Zr-based alloy with 34{approx}38 wt% U. In order to verify the technologies for the design and manufacturing of the fuel and get a license, performance tests were carried out. Experimental Fuel Assembly (EFA) manufactured in KAERI is being successfully irradiated in the MIR reactor of RIAR from September 4 2004, and it has achieved burnup of 0.21 g/cc as of January 25 2006. Thermal properties of irradiated Zr-U fuel were measured. Up to the phase transformation temperature, thermal diffusivity increased linearly in proportion to temperature. However its dependence on the burnup was not significant. RIA tests with 4 unirradiated Zr-U fuel rods were performed in Kurchatov Institute to establish a safety criterion. In the case of the un-irradiated Zr-U fuel, the energy deposition during the control rod ejection accident should be less than 172 cal/g to prevent the failure accompanying fuel fragmentation and dispersal. Finally the irradiation tests of fuel rods have been performed at HANARO. The HITE-2 test was successfully completed up to a burnup of 0.31 g/cc. The HITE-3 test began in February 2004 and will be continued up to a target burnup of 0.6 g/cc.

  18. Test Driven Development: Performing Art

    Science.gov (United States)

    Bache, Emily

    The art of Test Driven Development (TDD) is a skill that needs to be learnt, and which needs time and practice to master. In this workshop a select number of conference participants with considerable skill and experience are invited to perform code katas [1]. The aim is for them to demonstrate excellence and the use of Test Driven Development, and result in some high quality code. This would be for the benefit of the many programmers attending the conference, who could come along and witness high quality code being written using TDD, and get a chance to ask questions and provide feedback.

  19. Non-linear advanced control of the LHC inner triplet heat exchanger test unit

    International Nuclear Information System (INIS)

    Vinuela, E. Blanco; Cubillos, J. Casas; Prada Moraga, C. de; Cristea, S.

    2002-01-01

    The future Large Hadron Collider (LHC) at CERN will include eight interaction region final focus magnet systems, the so-called 'Inner Triplet', one on each side of the four beam collision points. The Inner Triplets will be cooled in a static bath of pressurized He II nominally at 1.9 K. This temperature is a control parameter and has very severe constraints in order to avoid the transition from the superconducting to normal resistive state. The main difference in these special zones with respect to a regular LHC cell is higher dynamic heat load unevenly distributed which modifies largely the process characteristics and hence the controller performance. Several control strategies have already been tested at CERN in a pilot plant (LHC String Test) which reproduced a LHC half-cell. In order to validate a common control structure along the whole LHC ring, a Nonlinear Model Predictive Control (NMPC) has been developed and implemented in the Inner Triplet Heat Exchanger Unit (IT-HXTU) at CERN. Automation of the Inner Triplet setup and the advanced control techniques deployed based on the Model Based Predictive Control (MBPC) principle are presented

  20. Development of a grinding-specific performance test set-up.

    Science.gov (United States)

    Olesen, C G; Larsen, B H; Andresen, E L; de Zee, M

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding performance.

  1. Effect of geometric parameters of liquid-gas separator units on phase separation performance

    Energy Technology Data Exchange (ETDEWEB)

    Mo, Songping; Chen, Xueqing; Chen, Ying [Guangdong University of Technology, Seoul (China); Yang, Zhen [Tsinghua University, Beijing (China)

    2015-07-15

    Five liquid-gas separator units were designed and constructed based on a new concept of a validated high-performance condenser. Each separator unit consists of two united T-junctions and an apertured baffle. The separator units have different header diameters or different baffles with different diameters of the liquid-gas separation hole. The phase separation characteristics of the units were investigated at inlet air superficial velocities from 1.0m/s to 33.0m/s and water superficial velocities from 0.0015 m/s to 0..50 m/s. The experimental results showed that the liquid height, liquid flow rate through the separation hole, and liquid separation efficiency increased with increased header diameter and decreased diameter of the separation hole. The geometric structures of the separator units affected the phase separation characteristics by influencing the liquid height in the header and the liquid flow rate through the separation hole.

  2. Reliability performance testing of totally encapsulating chemical protective suits

    International Nuclear Information System (INIS)

    Johnson, J.S.; Swearengen, P.M.

    1991-01-01

    The need to assure a high degree of reliability for totally encapsulating chemical protective (TECP) suits has been recognized by Lawrence Livermore National Laboratory's (LLNL) Hazards Control Department for some time. The following four tests were proposed as necessary to provide complete evaluation of TECP suit performance: 1. Quantitative leak test (ASTM draft), 2. Worst-case chemical exposure test (conceptual), 3. Pressure leak-rate test (complete, ASTM F1057-87), and 4. Chemical leak-rate test (ASTM draft). This paper reports on these tests which should be applied to measuring TECP suit performance in two stages: design qualification tests and field use tests. Test 1, 2, and 3 are used as design qualification tests, and tests 3 and 4 are used as field use tests

  3. Performance demonstration tests for eddy current inspection of steam generator tubing

    International Nuclear Information System (INIS)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1996-05-01

    This report describes the methodology and results for development of performance demonstration tests for eddy current (ET) inspection of steam generator tubes. Statistical test design principles were used to develop the performance demonstration tests. Thresholds on ET system inspection performance were selected to ensure that field inspection systems would have a high probability of detecting and and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented in detail. Statistical test design calculations for probability of detection and flaw sizing tests are described. A recommended performance demonstration test based on the design calculations is presented. A computer program for grading the probability of detection portion of the performance demonstration test is given

  4. Performance demonstration tests for eddy current inspection of steam generator tubing

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1996-05-01

    This report describes the methodology and results for development of performance demonstration tests for eddy current (ET) inspection of steam generator tubes. Statistical test design principles were used to develop the performance demonstration tests. Thresholds on ET system inspection performance were selected to ensure that field inspection systems would have a high probability of detecting and and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented in detail. Statistical test design calculations for probability of detection and flaw sizing tests are described. A recommended performance demonstration test based on the design calculations is presented. A computer program for grading the probability of detection portion of the performance demonstration test is given.

  5. Closure Report for Corrective Action Unit 254: Area 25, R-MAD Decontamination Facility, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    G. N. Doyle

    2002-02-01

    Corrective Action Unit (CAU) 254 is located in Area 25 of the Nevada Test Site (NTS), approximately 100 kilometers (km) (62 miles) northwest of Las Vegas, Nevada. The site is located within the Reactor Maintenance, Assembly and Disassembly (R-MAD) compound and consists of Building 3126, two outdoor decontamination pads, and surrounding areas within an existing fenced area measuring approximately 50 x 37 meters (160 x 120 feet). The site was used from the early 1960s to the early 1970s as part of the Nuclear Rocket Development Station program to decontaminate test-car hardware and tooling. The site was reactivated in the early 1980s to decontaminate a radiologically contaminated military tank. This Closure Report (CR) describes the closure activities performed to allow un-restricted release of the R-MAD Decontamination Facility.

  6. Test anxiety and academic performance in chiropractic students.

    Science.gov (United States)

    Zhang, Niu; Henderson, Charles N R

    2014-01-01

    Objective : We assessed the level of students' test anxiety, and the relationship between test anxiety and academic performance. Methods : We recruited 166 third-quarter students. The Test Anxiety Inventory (TAI) was administered to all participants. Total scores from written examinations and objective structured clinical examinations (OSCEs) were used as response variables. Results : Multiple regression analysis shows that there was a modest, but statistically significant negative correlation between TAI scores and written exam scores, but not OSCE scores. Worry and emotionality were the best predictive models for written exam scores. Mean total anxiety and emotionality scores for females were significantly higher than those for males, but not worry scores. Conclusion : Moderate-to-high test anxiety was observed in 85% of the chiropractic students examined. However, total test anxiety, as measured by the TAI score, was a very weak predictive model for written exam performance. Multiple regression analysis demonstrated that replacing total anxiety (TAI) with worry and emotionality (TAI subscales) produces a much more effective predictive model of written exam performance. Sex, age, highest current academic degree, and ethnicity contributed little additional predictive power in either regression model. Moreover, TAI scores were not found to be statistically significant predictors of physical exam skill performance, as measured by OSCEs.

  7. Well Installation Report for Corrective Action Unit 443, Central Nevada Test Area, Nye County, Nevada

    International Nuclear Information System (INIS)

    Tim Echelard

    2006-01-01

    A Corrective Action Investigation (CAI) was performed in several stages from 1999 to 2003, as set forth in the ''Corrective Action Investigation Plan for the Central Nevada Test Area Subsurface Sites, Corrective Action Unit 443'' (DOE/NV, 1999). Groundwater modeling was the primary activity of the CAI. Three phases of modeling were conducted for the Faultless underground nuclear test. The first phase involved the gathering and interpretation of geologic and hydrogeologic data, and inputting the data into a three-dimensional numerical model to depict groundwater flow. The output from the groundwater flow model was used in a transport model to simulate the migration of a radionuclide release (Pohlmann et al., 2000). The second phase of modeling (known as a Data Decision Analysis [DDA]) occurred after NDEP reviewed the first model. This phase was designed to respond to concerns regarding model uncertainty (Pohll and Mihevc, 2000). The third phase of modeling updated the original flow and transport model to incorporate the uncertainty identified in the DDA, and focused the model domain on the region of interest to the transport predictions. This third phase culminated in the calculation of contaminant boundaries for the site (Pohll et al., 2003). Corrective action alternatives were evaluated and an alternative was submitted in the ''Corrective Action Decision Document/Corrective Action Plan for Corrective Action Unit 443: Central Nevada Test Area-Subsurface'' (NNSA/NSO, 2004). Based on the results of this evaluation, the preferred alternative for CAU 443 is Proof-of-Concept and Monitoring with Institutional Controls. This alternative was judged to meet all requirements for the technical components evaluated and will control inadvertent exposure to contaminated groundwater at CAU 443

  8. Drop Performance Test of CRDMs for JRTR

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Chung, Jong-Ha [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Jung-Hyun [POSCO Plandtec Co. Ltd, Ulsan (Korea, Republic of); Lee, Kwan-Hee [RIST, Pohang (Korea, Republic of)

    2015-10-15

    The drop test results of CRDMs with AC-type electromagnet show that the initial delay times are not satisfied with the requirement, 0.15 seconds. After the replacement of the electromagnet from AC-type to DCtype, the drop times of CARs and accelerations due to the impact of moving parts are satisfied with all requirements. As a result, it is found that four CRDMs to be installed at site have a good drop performance, and meet all performance requirements. A control rod drive mechanism (CRDM) is a device to control the position of a control absorber rod (CAR) in the core by using a stepping motor which is commanded by the reactor regulating system (RRS) to control the reactivity during the normal operation of the reactor. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the performances such as the stepping, drop, endurance, vibration, seismic and structural integrity for active components. Especially, the CAR drop curves are important data for the safety analysis. This paper describes the test results to demonstrate the drop performances of a prototype and 4 CRDMs to be installed at site. The tests are carried out at a test rig simulating the actual reactor's conditions.

  9. Numerical simulation of aerodynamic performance of a couple multiple units high-speed train

    Science.gov (United States)

    Niu, Ji-qiang; Zhou, Dan; Liu, Tang-hong; Liang, Xi-feng

    2017-05-01

    In order to determine the effect of the coupling region on train aerodynamic performance, and how the coupling region affects aerodynamic performance of the couple multiple units trains when they both run and pass each other in open air, the entrance of two such trains into a tunnel and their passing each other in the tunnel was simulated in Fluent 14.0. The numerical algorithm employed in this study was verified by the data of scaled and full-scale train tests, and the difference lies within an acceptable range. The results demonstrate that the distribution of aerodynamic forces on the train cars is altered by the coupling region; however, the coupling region has marginal effect on the drag and lateral force on the whole train under crosswind, and the lateral force on the train cars is more sensitive to couple multiple units compared to the other two force coefficients. It is also determined that the component of the coupling region increases the fluctuation of aerodynamic coefficients for each train car under crosswind. Affected by the coupling region, a positive pressure pulse was introduced in the alternating pressure produced by trains passing by each other in the open air, and the amplitude of the alternating pressure was decreased by the coupling region. The amplitude of the alternating pressure on the train or on the tunnel was significantly decreased by the coupling region of the train. This phenomenon did not alter the distribution law of pressure on the train and tunnel; moreover, the effect of the coupling region on trains passing by each other in the tunnel is stronger than that on a single train passing through the tunnel.

  10. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  11. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Younggwang nuclear power plant unit1

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-08-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Yonggwang site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 1 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.555E+18, 1.662E+19, 3.358E+19, and 4.521E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.859 for the 1st through 4th testing and the calculational uncertainty, 11.80% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.551E+19 n/cm{sup 2} based on the end of 12th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.929E+19, 4.880E+19, 5.831E+19 and 6.782E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 1 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 4 refs., 41 figs., 35 tabs. (Author)

  12. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Yonggwang nuclear power plant unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-02-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.762E+18, 1.5391E+19, 3.5119E+19, and 4.2610E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.899 for the 1st through 4th testing and the calculational uncertainty, 12.3% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.357E+19 n/cm{sup 2} based on the end of 11th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.525E+19, 4.337E+19, 5.148E+19 and 5.960E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 2 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 48 refs., 35 figs., 42 tabs. (Author)

  13. Cryogenic explosion environment modeling and testing of space shuttle and light-weight radioisotope heater unit interactions

    International Nuclear Information System (INIS)

    Johnson, E.W.

    1985-10-01

    In order to assess the risk to the world's populace in the event of a Space Shuttle accident when radioisotope-containing heat sources are on board, testing of that system must be performed to determine release point, environments required, and the size distribution of the released fuel. To evaluate the performance of the Light-Weight Radioisotope Heater Unit (LWRHU) (101 of these 1-W items are placed on the Galileo spacecraft which will be launched from the Space Shuttle), some high-velocity impact and flyer plate testing was carried out. The results showed that a bare urania-fueled LWRHU clad (approximately 1-mm thick platinum-30 wt % rhodium alloy) will withstand 1100 m/s flyer plate (3.5-mm thick aluminum) impacts and 330 m/s impacts upon the Space Shuttle floor (approximately 12-mm thick aluminum) without rupture or fuel release. Velocities in the order of 600 m/s on a steel surface will cause clad failure with fuel release. The fuel breakup patterns were characterized as to quantity in a specific size range. These data were employed in the formal Safety Analysis Report for the LWRHU to support the planned 1986 Galileo launch. 19 figs

  14. New test methods for BIPV. Results from IP performance

    International Nuclear Information System (INIS)

    Jol, J.C.; Van Kampen, B.J.M.; De Boer, B.J.; Reil, F.; Geyer, D.

    2009-11-01

    Within the Performance project new test procedures for PV building products and the building performance as a whole when PV is applied in buildings have been drafted. It has resulted in a first draft of new test procedures for PV building products and proposals for tests for novel BIPV technology like thin film. The test proposed are a module breakage test for BIPV products, a fire safety test for BIPV products and a dynamic load test for BIPV products. Furthermore first proposals of how flexible PV modules could be tested in an appropriate way to ensure long time quality and safety of these new products are presented.

  15. Diagnosing acute HIV infection: The performance of quantitative HIV-1 RNA testing (viral load) in the 2014 laboratory testing algorithm.

    Science.gov (United States)

    Wu, Hsiu; Cohen, Stephanie E; Westheimer, Emily; Gay, Cynthia L; Hall, Laura; Rose, Charles; Hightow-Weidman, Lisa B; Gose, Severin; Fu, Jie; Peters, Philip J

    2017-08-01

    New recommendations for laboratory diagnosis of HIV infection in the United States were published in 2014. The updated testing algorithm includes a qualitative HIV-1 RNA assay to resolve discordant immunoassay results and to identify acute HIV-1 infection (AHI). The qualitative HIV-1 RNA assay is not widely available; therefore, we evaluated the performance of a more widely available quantitative HIV-1 RNA assay, viral load, for diagnosing AHI. We determined that quantitative viral loads consistently distinguished AHI from a false-positive immunoassay result. Among 100 study participants with AHI and a viral load result, the estimated geometric mean viral load was 1,377,793copies/mL. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Assessment of materials selection and performance for direct-coal- liquefaction plants in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, A.R.; Judkins, R.R.; Keiser, J.R.

    1996-09-01

    Several direct coal liquefaction processes have been demonstrated at the pilot plant level in the United States. Presently only one plant remains operational, namely, the Hydrocarbon Technologies, Inc., 4.0- ton-per-day process development unit in Lawrenceville, New Jersey. The period from 1974 to 1982 saw the greatest amount of development of direct coal liquefaction in the United States with four major pilot plants being devoted to variants of this technology. The plants included the SRC-I plant at Wilsonville, Alabama, which operated from 1974 to 1992; the SRC-I/II plant at Fort Lewis, Washington, which operated from 1974 to 1981; the H-Coal plant at Catlettsburg, Kentucky, which operated from 1980 to 1982; and the Exxon Coal Liquefaction Pilot Plant at Baytown, Texas, which operated from 1980 to 1982. Oak Ridge National Laboratory scientists and engineers were actively involved in many phases and technical disciplines at all four of these plants, especially in materials testing, evaluation, and failure analyses. In addition, ORNL materials scientists and engineers conducted reviews of the demonstration and commercial plant designs for materials selections. The ORNL staff members worked closely with materials engineers at the pilot plants in identifying causes of materials degradation and failures, and in identifying solutions to these problems. This report provides a comprehensive summary of those materials activities. Materials performance data from laboratory and coal liquefaction pilot plant tests, failure analyses, and analyses of components after use in pilot plants were reviewed and assessed to determine the extent and causes of materials degradation in direct coal liquefaction process environments. Reviews of demonstration and commercial plant design documents for materials selections were conducted. These reviews and assessments are presented to capture the knowledge base on the most likely materials of construction for direct coal liquefaction plants.

  17. Corrosion performance tests for reinforcing steel in concrete : test procedures.

    Science.gov (United States)

    2009-09-01

    The existing test method to assess the corrosion performance of reinforcing steel embedded in concrete, mainly : ASTM G109, is labor intensive, time consuming, slow to provide comparative results, and often expensive. : However, corrosion of reinforc...

  18. Impact of Educational Level on Performance on Auditory Processing Tests.

    Science.gov (United States)

    Murphy, Cristina F B; Rabelo, Camila M; Silagi, Marcela L; Mansur, Letícia L; Schochat, Eliane

    2016-01-01

    Research has demonstrated that a higher level of education is associated with better performance on cognitive tests among middle-aged and elderly people. However, the effects of education on auditory processing skills have not yet been evaluated. Previous demonstrations of sensory-cognitive interactions in the aging process indicate the potential importance of this topic. Therefore, the primary purpose of this study was to investigate the performance of middle-aged and elderly people with different levels of formal education on auditory processing tests. A total of 177 adults with no evidence of cognitive, psychological or neurological conditions took part in the research. The participants completed a series of auditory assessments, including dichotic digit, frequency pattern and speech-in-noise tests. A working memory test was also performed to investigate the extent to which auditory processing and cognitive performance were associated. The results demonstrated positive but weak correlations between years of schooling and performance on all of the tests applied. The factor "years of schooling" was also one of the best predictors of frequency pattern and speech-in-noise test performance. Additionally, performance on the working memory, frequency pattern and dichotic digit tests was also correlated, suggesting that the influence of educational level on auditory processing performance might be associated with the cognitive demand of the auditory processing tests rather than auditory sensory aspects itself. Longitudinal research is required to investigate the causal relationship between educational level and auditory processing skills.

  19. Correlation of United States Medical Licensing Examination and Internal Medicine In-Training Examination Performance

    Science.gov (United States)

    Perez, Jose A., Jr.; Greer, Sharon

    2009-01-01

    The Internal Medicine In-Training Examination (ITE) is administered during residency training in the United States as a self-assessment and program assessment tool. Performance on this exam correlates with outcome on the American Board of Internal Medicine Certifying examination. Internal Medicine Program Directors use the United States Medical…

  20. GPS Device Testing Based on User Performance Metrics

    Science.gov (United States)

    2015-10-02

    1. Rationale for a Test Program Based on User Performance Metrics ; 2. Roberson and Associates Test Program ; 3. Status of, and Revisions to, the Roberson and Associates Test Program ; 4. Comparison of Roberson and DOT/Volpe Programs

  1. MFTF test coil construction and performance

    International Nuclear Information System (INIS)

    Cornish, D.N.; Zbasnik, J.P.; Leber, R.L.; Hirzel, D.G.; Johnston, J.E.; Rosdahl, A.R.

    1978-01-01

    A solenoid coil, 105 cm inside the 167 cm outside diameter, has been constructed and tested to study the performance of the stabilized Nb--Ti conductor to be used in the Mirror Fusion Test Facility (MFTF) being built at Lawrence Livermore Laboratory. The insulation system of the test coil is identical to that envisioned for MFTF. Cold-weld joints were made in the conductor at the start and finish of each layer; heaters were fitted to some of these joints and also to the conductor at various locations in the winding. This paper gives details of the construction of the coil and the results of the tests carried out to determine its propagation and recovery characteristics

  2. Composite Monopack for 120mm Mortar, With Plastic Pallet Adapters on a 42" x 53" Wooden Pallet, MIL-STD-1660 Tests, "Design Criteria for Ammunition Unit Loads", and Extreme Temperature Tests

    National Research Council Canada - National Science Library

    Dugan, Jeffery L

    2005-01-01

    .... The test units were tested in accordance with the procedures set forth in MIL-STD-1660. Stacking, repetitive shock, edgewise-rotational drop, incline-impact, forklifting, and disassembly testing were conducted on the test units...

  3. Dosimetric evaluation of Radiotherapy units wit 60Co

    International Nuclear Information System (INIS)

    Leon, B. Salinas de; Tovar M, V.; Becerril V, A.

    2000-01-01

    The SSDL network of the IAEA performs, every year, quality audit tests for radiotherapy services ( 60 Co units and linear accelerators), and for national SSDL as well. Because of the SSDL-Mexico results in these tests and due to our enthusiasm and confidence in our work, a parallel test has been done , which is described in this talk as well as the results. Nowadays, a second parallel test goes up, which could confirm our optimism and open the possibility to our country to start a national dosimetric audit of 60 Co radiotherapy units. (Author)

  4. Effects of zinc injection from hot functional test at Tomari Unit 3

    International Nuclear Information System (INIS)

    Hayakawa, Hitoshi; Mino, Yoshitaka; Nakahama, Satoshi; Aizawa, Yamato; Shimizu, Yuichi; Umehara, Ryuji; Kogawa, Noritaka

    2012-09-01

    At Tomari Nuclear Power Station unit 3 (hereafter Tomari unit 3, PWR, commercial operation from December 2009), the zinc injection for dose-rate reduction was started as early as at the Hot Functional Test (hereafter HFT) stage, for the first time in the world. The results of the Steam Generator (hereafter SG) insert plate analysis and the ambient dose-rate measurement till the end of the test operation reported heretofore, show the formation of the robust oxide film on the primary material surfaces and the associated corrosion suppression effect, and a considerable dose-rate reduction of about 40 to 60% lower than a reference plant. (*: Asian Water Chemistry Symposium in Nagoya on 2009 and NPC2010 in Canada). The material of SG tube is Alloy 690TT in Tomari unit 3. Generally, the dose-rates of the plants with Alloy 690TT SG are the highest at the 1. or 2. refueling outage (hereafter RFO), due to the effects of the Ni dissolution from the initial corrosion of Alloy 690TT. Therefore, the dose-rate of Tomari unit 3 at the 1. RFO is compared with those of the other Japanese PWR plants at their 1. RFO. As the result, the dose-rates inside the main components such as SG, Main Coolant Pipe (hereafter MCP) and Reactor Vessel (hereafter RV) are about 50% lower at the 1. RFO of Tomari unit 3 than those of a reference plant (a 3-Loop PWR plant in Japan). Therefore, an additional dose-rate reduction effects is expected by the Ni release rate reduction from Alloy 690TT and the effect of zinc injection. In this report, the actual dose-rates at the primary main components, the trends of the water chemistry and dose rates reduction effect with the zinc injection at the 1. RFO (offline in January 2011) of Tomari unit 3 are introduced. Also, a part of the experiences at the 2. RFO (offline in May 2012) is introduced. (authors)

  5. Contextualism adds realism: nursing students' perceptions of and performance in numeracy skills tests.

    Science.gov (United States)

    Ramjan, Lucie M

    2011-11-01

    This project investigated nursing students' perceptions of and performance in a de-contextualised diagnostic maths paper (i.e. questions only) and a contextualised diagnostic maths paper (i.e. visual pictures along with questions). Sampling was purposive, the criteria being that participants would be from the population of student nurses (n=700) in their second year, of a three-year Bachelor of Nursing course, undertaking a Unit 'Medical-Surgical Nursing 1' (MSN1) at one of four campuses across the University of Western Sydney (UWS), NSW, Australia. The numerical test scores for both papers were analysed with the assistance of SPSS software and a Professional Development Officer. The survey data were analysed manually and thematically by the researcher. There was a substantive improvement in scores from Test 1 (de-contextualised) to Test 2 (contextualised). It is uncertain whether the change occurred because Test 2 is a genuinely better presentation than Test 1 or just a practice effect. Nevertheless, the contextualised paper was preferred by the majority of students (80%). Students preferred the visual images and revealed that it led to a "deeper learning" of numeracy skills, reduced stress and anxiety levels and simulated 'the real life' clinical setting, thus adding "an element of realism" to the situation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. 40 CFR 60.2155 - May I conduct performance testing less often?

    Science.gov (United States)

    2010-07-01

    ... performance test. (c) If a performance test shows a deviation from an emission limitation for particulate... 40 Protection of Environment 6 2010-07-01 2010-07-01 false May I conduct performance testing less... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for...

  7. 78 FR 47011 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Science.gov (United States)

    2013-08-02

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software... revised regulatory guide (RG), revision 1 of RG 1.171, ``Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants.'' This RG endorses American National Standards...

  8. 77 FR 50722 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Science.gov (United States)

    2012-08-22

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software...) is issuing for public comment draft regulatory guide (DG), DG-1208, ``Software Unit Testing for Digital Computer Software used in Safety Systems of Nuclear Power Plants.'' The DG-1208 is proposed...

  9. Performance testing SPECT systems: Recent developments

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.

    1985-01-01

    A protocol is used to test as many currently available systems as possible, including both rotating gamma camera systems from GE, Siemens, Toshiba, Technicare, Elscint, Philips, Picker, etc, and single/multi slice system such as the Medimatic. This paper indicates changes that have occurred with respect to preliminary results previously published. Reconstructions were performed in a standard manner, using a Ramp filter and without attenuation correction, in order to reduce the effect of differences in software. The Jaszczak phantom was used to assess overall image quality. Tests were performed using the different collimators available. Image quality improved with better spatial resolution, even at the expense of sensitivity. Non-circular orbits, where available, were tested, and resolution was comparing for various positions and directions. With double headed systems, the results obtained were compared to those using a single head alone. Some gain in image quality seems to have been achieved by better uniformity resulting from improved correction circuitry, by the use of non-circular orbits, and from scatter correction. Potential still exists to improve collimator design

  10. Individual differences in infant fearfulness and cognitive performance: a testing, performance, or competence effect?

    Science.gov (United States)

    Rieser-Danner, Loretta A

    2003-02-01

    The author conducted 2 studies to examine the relations between infant fear and cognitive testing performance in 12-month-old infants. In Study 1, fear was assessed by using 2 standard temperament questionnaires and a laboratory-based, standardized stranger approach. Individual differences in cognitive development were assessed using the Object Permanence Scale of the Infant Psychological Development Scales (I. C. Uzgiris & J. M. Hunt, 1975). All 3 assessments of fear significantly predicted object permanence performance, with correlations ranging from -.32 to -.35. In Study 2, fear was assessed via a maternal report questionnaire, and habituation performance was assessed via a basic-level categorization task. Familiarity with the examiner and with the testing environment was manipulated to test for a familiarity influence on performance. Testing revealed individual differences in both fear and habituation. Results suggest that highly fearful infants required more trials to habituate and were less likely to meet the habituation criterion than infants who were less fearful. Methodological and conceptual implications of these results are discussed.

  11. High Performance Residential Housing Units at U.S. Coast Guard Base Kodiak: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Romero, R.; Hickey, J.

    2013-10-01

    The United States Coast Guard (USCG) constructs residential housing throughout the country using a basic template that must meet the minimum Leadership in Energy and Environmental Design (LEED) Silver criteria or better for the units. In Kodiak, Alaska, USCG is procuring between 24 and 100 residential multi-family housing units. Priorities for the Kodiak project were to reduce overall energyconsumption by at least 20% over existing units, improve envelope construction, and evaluate space heating options. USCG is challenged with maintaining similar existing units that have complicated residential diesel boilers. Additionally, fuel and material costs are high in Kodiak. While USCG has worked to optimize the performance of the housing units with principles of improved buildingenvelope, the engineers realize there are still opportunities for improvement, especially within the heating, ventilation, and air conditioning (HVAC) system and different envelope measures. USCG staff also desires to balance higher upfront project costs for significantly reduced life-cycle costs of the residential units that have an expected lifetime of 50 or more years. To answer thesequestions, this analysis used the residential modeling tool BEoptE+ to examine potential energy- saving opportunities for the climate. The results suggest criteria for achieving optimized housing performance at the lowest cost. USCG will integrate the criteria into their procurement process. To achieve greater than 50% energy savings, USCG will need to specify full 2x 6 wood stud R-21 insulationwith two 2 inches of exterior foam, R-38 ceiling insulation or even wall insulation in the crawl space, and R-49 fiberglass batts in a the vented attic. The air barrier should be improved to ensure a tight envelope with minimal infiltration to the goal of 2.0 ACH50. With the implementation of an air source heat pump for space heating requirements, the combination of HVAC and envelope savings inthe residential unit can save

  12. Comparative energy and exergy performance assessments of a microcogenerator unit in different electricity mix scenarios

    International Nuclear Information System (INIS)

    Gonçalves, Pedro; Angrisani, Giovanni; Roselli, Carlo; Gaspar, Adélio R.; Gameiro da Silva, Manuel

    2013-01-01

    Highlights: • Experimental and energy–exergy modelling of a 6 kW micro-combined heat and power unit. • Evaluation of energy and exergy efficiencies for performance assessment. • Use of exergy and energy indicators for comparison with a reference system. • Use of different renewables supply options into the electric and heat reference system. • The electric grid mix of Portugal and Italy is used and discussed. - Abstract: The Directive 2004/8/EC on the promotion of cogeneration proposes a comparative indicator based on primary energy savings, neglecting some important thermodynamic aspects, such as exergy. This study aims to compare and discuss the usefulness of a set of complementary indicators for performance assessments of cogeneration systems, concerning thermodynamic principles based on first and second law (the exergy approach). As case study, a 6 kW electric output micro-combined heat and power unit was experimentally tested and a model of the unit was developed in TRNSYS. Considering as reference a set of different heat and electricity scenarios, including the actual electric mixes of Portugal and Italy, the indicators case incon (PES) and Primary and Total Irreversibilities Savings (PIS and TIS), as well as energy and exergy renewability ratios were assessed and discussed. The results show that the use of MCHP has higher advantages for the Italian electric grid, than an equivalent scenario considering the Portuguese electric network as reference. As result, for a particular scenario analysed, PES and PIS have 3% and 6% for Portugal, and 10% and 18% for Italy, respectively. Furthermore, for one particular scenario evaluated, the indicators energetic and exergetic renewability ratios have 23% and 14%, respectively for the Portuguese electric grid, and 19% and 10% for the Italian electric system

  13. Fabrication and testing history prototypes and production units

    Energy Technology Data Exchange (ETDEWEB)

    1954-09-01

    From April, 1951 to Aug, 1954, New York Shipbuilding Corp. carried out a subcontract with E.I. du Pont de Nemours & Company that was without parallel in the shipyard`s history. The work, designated the NYX Project for reasons of security, was vital to the operations of the Savannah River Plant, Aiken, S.C., which was then being designed and constructed by du Pont for the Atomic Energy Commission. It consisted of three broad parts: developmental and experimental work; fabrication and testing of a prototype unit; fabrication of production units. Five production units were ultimately built, one of them converted from the prototype. All were fabricated from stainless steel, and involved welding techniques, control of thermal distortion and tolerances never previously attempted on assemblies of comparable size. Du Pont`s technical experience and the background of New York Ship in heavy construction, particularly in the fabrication of naval gun turrets, were combined from the outset to resolve the difficult fabrication problems that occurred almost daily. Representatives of both companies worked together as a team in the shops and at supervisory levels to an unprecedented extent. The report is intended primarily to summarize New York Ship`s part in the project, but also includes some of du Pont`s activities since the work of the two organizations was so interrelated. Because of the scope of the program, it will not always be possible to provide detailed information, but rather to record what happened in general terms. Where the reader desires more specific data, he should refer to original plans and records, including various reports compiled during the course of the project.

  14. Initial startup and operations of Yonggwang Units 3 and 4

    International Nuclear Information System (INIS)

    Collier, T.J.; Chari, D.R.; Kiraly, F.

    1996-01-01

    A significant milestone in the nuclear power industry was achieved in 1995, when Yonggwang (YGN) Units 3 and 4 were accepted into in commercial operation by Korea Electric Power Corporation (KEPCO). YGN Unit 3 was accepted into commercial operation on March 31, 1995, the original date established during project initiation. YGN Unit 4 was accepted into operation on January 1, 1996, 3 months ahead of schedule. Each YGN unit produces approximately 1,050 Mwe and supplies approximately ten percent of the total electric power demand in the Republic of Korea (ROK). The overall plant efficiency is approximately 37% which is at least 1% higher than most nuclear units. Since achieving commercial operation, YGN Unit 3 has operated at essentially full power which has resulted in an annual performance rate in excess of 85%. YGN Unit 3 is the first of six pressurized water reactors which are currently under design and construction in the ROK and serves as the reference design for the Korean Standard Nuclear Power Plant program. Both YGN Units 3 and 4 include a System 800 Nuclear Steam Supply System (NSSS). The NSSS is rated at 2,815 Mwth and is the ABB-CE standard design. The design includes numerous advanced design features which enhance plant safety, performance and operability. A well executed startup test program was successfully completed on both units prior to commercial operation. A summary of the YGN NSSS design features, the startup test program and selected test results demonstrating the performance of those features are presented in this paper

  15. Closure report for housekeeping category, Corrective Action Unit 348, Nevada Test Site

    International Nuclear Information System (INIS)

    1998-01-01

    This Closure Report summarizes the corrective actions which were completed at twelve Corrective Action Sites within Corrective Action Unit 348 at the Nevada Test Site. Current site descriptions, observations and identification of wastes removed are included on FFACO Corrective Action Site housekeeping closure verification forms

  16. Closure report for housekeeping category, Corrective Action Unit 347, Nevada Test Site

    International Nuclear Information System (INIS)

    1998-01-01

    This Closure Report summarizes the corrective actions which were completed at the Corrective Action Sites within Corrective Action Unit 347 at the Nevada Test Site. Current site descriptions, observations and identification of wastes removed are included on FFACO Corrective Action Site housekeeping closure verification forms

  17. DPM PERFORMANCE TESTING USING RASPBERRY PIS

    CERN Document Server

    Regala, M

    2013-01-01

    This is the final report from attending CERN’s Summer Student Programme. The project goal was to do performance testing on the Disk Pool Manager (DPM), a lightweight, reliable, grid-aware storage software used to store and retrieve data produced by CERN’s LHC experiments using the small, low-end ARM powered devices named Raspberry Pis. The idea behind it was to reason if it’s possible to use a cluster of lower-end, under-capable devices to run DPM, and to conclude if it would be more energy efficient than running it on oversized machines, with the same or comparable performance. If this hypothesis was true, the power-hungry machines could be ditched in favour of these small devices, leading to an enormous saving in overall power consumption and hence, overall cost. In this report, I describe what was the initial project goal and intended outcomes, proceeding to explain the underlying technologies used. Afterwards, I’ll explain the setup used, the tests performed, and the conclusions reached. iii

  18. Laboratory- and field-based testing as predictors of skating performance in competitive-level female ice hockey

    Directory of Open Access Journals (Sweden)

    Henriksson T

    2016-08-01

    Full Text Available Tommy Henriksson,1,2 Jason D Vescovi,3 Anncristine Fjellman-Wiklund,4 Kajsa Gilenstam1 1Sport Medicine Unit, Department of Community Medicine and Rehabilitation, 2The National Graduate School of Gender Studies, Umeå University, Umeå, Sweden; 3Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, ON, Canada; 4Physiotherapy Unit, Department of Community Medicine and Rehabilitation, Umeå University, Umeå, Sweden Objectives: The purpose of this study was to examine whether field-based and/or laboratory-based assessments are valid tools for predicting key performance characteristics of skating in competitive-level female hockey players.Design: Cross-sectional study.Methods: Twenty-three female ice hockey players aged 15–25 years (body mass: 66.1±6.3 kg; height: 169.5±5.5 cm, with 10.6±3.2 years playing experience volunteered to participate in the study. The field-based assessments included 20 m sprint, squat jump, countermovement jump, 30-second repeated jump test, standing long jump, single-leg standing long jump, 20 m shuttle run test, isometric leg pull, one-repetition maximum bench press, and one-repetition maximum squats. The laboratory-based assessments included body composition (dual energy X-ray absorptiometry, maximal aerobic power, and isokinetic strength (Biodex. The on-ice tests included agility cornering s-turn, cone agility skate, transition agility skate, and modified repeat skate sprint. Data were analyzed using stepwise multivariate linear regression analysis. Linear regression analysis was used to establish the relationship between key performance characteristics of skating and the predictor variables.Results: Regression models (adj R2 for the on-ice variables ranged from 0.244 to 0.663 for the field-based assessments and from 0.136 to 0.420 for the laboratory-based assessments. Single-leg tests were the strongest predictors for key performance characteristics of skating. Single leg standing

  19. Non-linear Loudspeaker Unit Modelling

    DEFF Research Database (Denmark)

    Pedersen, Bo Rohde; Agerkvist, Finn T.

    2008-01-01

    Simulations of a 6½-inch loudspeaker unit are performed and compared with a displacement measurement. The non-linear loudspeaker model is based on the major nonlinear functions and expanded with time-varying suspension behaviour and flux modulation. The results are presented with FFT plots of thr...... frequencies and different displacement levels. The model errors are discussed and analysed including a test with loudspeaker unit where the diaphragm is removed....

  20. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  1. Pharmacists performing quality spirometry testing: an evidence based review.

    Science.gov (United States)

    Cawley, Michael J; Warning, William J

    2015-10-01

    The scope of pharmacist services for patients with pulmonary disease has primarily focused on drug related outcomes; however pharmacists have the ability to broaden the scope of clinical services by performing diagnostic testing including quality spirometry testing. Studies have demonstrated that pharmacists can perform quality spirometry testing based upon international guidelines. The primary aim of this review was to assess the published evidence of pharmacists performing quality spirometry testing based upon American Thoracic Society/European Respiratory Society (ATS/ERS) guidelines. In order to accomplish this, the description of evidence and type of outcome from these services were reviewed. A literature search was conducted using five databases [PubMed (1946-January 2015), International Pharmaceutical Abstracts (1970 to January 2015), Cumulative Index of Nursing and Allied Health Literature, Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews] with search terms including pharmacy, spirometry, pulmonary function, asthma or COPD was conducted. Searches were limited to publications in English and reported in humans. In addition, Uniform Resource Locators and Google Scholar searches were implemented to include any additional supplemental information. Eight studies (six prospective multi-center trials, two retrospective single center studies) were included. Pharmacists in all studies received specialized training in performing spirometry testing. Of the eight studies meeting inclusion and exclusion criteria, 8 (100%) demonstrated acceptable repeatability of spirometry testing based upon standards set by the ATS/ERS guidelines. Acceptable repeatability of seven studies ranged from 70 to 99% consistent with published data. Available evidence suggests that quality spirometry testing can be performed by pharmacists. More prospective studies are needed to add to the current evidence of quality spirometry testing performed by

  2. 78 FR 65007 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3

    Science.gov (United States)

    2013-10-30

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00026; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion...

  3. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from equipment suppliers of manufacturers in new and existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing quality status of the equipment. A working group has developed guidelines for these acceptance tests. Items to be measured are reported and proposed limiting values and their tolerances are discussed. (author)

  4. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from the equipment suppliers or manufacturers in new and also existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing the quality status of the equipment. A working group has developed guidelines for these acceptance tests. The items to be measured are reported and the proposed limiting values and their tolerances are discussed. (author)

  5. Verification test for three WindCube WLS7 LiDARs at the Høvsøre test site

    DEFF Research Database (Denmark)

    Gottschall, Julia; Courtney, Michael

    The report describes the procedure of testing ground-based WindCube lidars (manufactured by the French company Leosphere) at the Høvsøre test site in comparison to reference sensors mounted at a meteorological mast. Results are presented for three tested units – in detail for unit WLS7-0062, and ......-0062, and in a summary for units WLS7-0064 and WLS7-0066. The verification test covers the evaluation of measured mean wind speeds, wind directions and wind speed standard deviations. The data analysis is basically performed in terms of different kinds of regression analyses.......The report describes the procedure of testing ground-based WindCube lidars (manufactured by the French company Leosphere) at the Høvsøre test site in comparison to reference sensors mounted at a meteorological mast. Results are presented for three tested units – in detail for unit WLS7...

  6. Play for Performance: Using Computer Games to Improve Motivation and Test-Taking Performance

    Science.gov (United States)

    Dennis, Alan R.; Bhagwatwar, Akshay; Minas, Randall K.

    2013-01-01

    The importance of testing, especially certification and high-stakes testing, has increased substantially over the past decade. Building on the "serious gaming" literature and the psychology "priming" literature, we developed a computer game designed to improve test-taking performance using psychological priming. The game primed…

  7. 78 FR 53483 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3

    Science.gov (United States)

    2013-08-29

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00025; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria (ITAAC) completion...

  8. 78 FR 53484 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 4

    Science.gov (United States)

    2013-08-29

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00026; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 4 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria (ITAAC) completion...

  9. Demonstration Testing of a Thermal Desorption Unit to Receive and Treat Waste with Unlimited Concentration of PCBs - 13437

    Energy Technology Data Exchange (ETDEWEB)

    Orton, Timothy L. [EnergySolutions, 423 West 300 South, Salt Lake City, UT 84101 (United States); Palmer, Carl R. [TD.X Associates LP, 148 South Dowlen Road, PMB 700, Beaumont, TX 77707 (United States)

    2013-07-01

    For the last nine years, EnergySolutions and TD*X Associates LP have teamed up to provide the most comprehensive organic removal treatment process in the radioactive waste industry. The high performance thermal desorption unit (HP-TDU) located at the EnergySolutions Clive facility in Utah has successfully processed over 1,850 tons of organically contaminated radioactive mixed waste. Products from the HP-TDU system include a radioactively contaminated dry solid material that can be disposed in the on-site landfill and an organic condensate with high thermal energy content that is generally below background radiation and capable of free-release to a non-radioactive incinerator. Over the years, Permits and approvals have been obtained through the state of Utah, United States Environmental Protection Agency (USEPA) Region 8, and USEPA headquarters that enable the treatment of several waste categories including volatile and semi-volatile organic compounds, combustion-coded (CMBST) compounds, volatile metals, and polychlorinated biphenyls (PCBs). The unit has recently successfully completed Demonstration Testing for PCB concentrations up to 660,000 ppm (parts per million). Solid processed material from this Demonstration Testing was less than two ppm PCBs in three separate treatment runs; reprocessing or additional treatment was not needed to meet this limit. Through post-demonstration permitting, the system is unlimited in scope as approval has been given to receive and solidify up to pure PCBs down to this processing limit concentration to complete treatment of mixed waste. (authors)

  10. He II Heat Exchanger Test Unit for the LHC Inner Triplet

    CERN Document Server

    Blanco-Viñuela, E; Huang, Y; Nicol, T H; Peterson, T; Van Weelderen, R

    2002-01-01

    The Inner Triplet Heat Exchanger Test Unit (IT-HXTU) is a 30-m long thermal model designed at Fermilab, built in US industry, fully automated and tested at CERN as part of the US LHC program to develop the LHC Interaction Region quadrupole system. The cooling scheme of the IT-HXTU is based on heat exchange between stagnant pressurized He II in the magnet cold mass and saturated He II (two-phase) flowing in a heat exchanger located outside of and parallel to the cold mass. The purposes of this test are, among others, to validate the proposed cooling scheme and to define an optimal control strategy to be implemented in the future LHC accelerator. This paper discusses the results for the heat exchanger test runs and emphasizes the thermal and hydraulic behavior of He II for the inner triplet cooling scheme.

  11. Closure Report for Corrective Action Unit 110: Areas 3 RWMS U-3ax/bl Disposal Unit, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    J. L. Smith

    2001-08-01

    This Closure Report (CR) has been prepared for the Area 3 Radioactive Waste Management Site (RWMS) U-3ax/bl Disposal Unit Corrective Action Unit (CAU) 110 in accordance with the reissued (November 2000) Resource Conservation and Recovery Act (RCRA) Part B operational permit NEV HW009 (Nevada Division of Environmental Protection [NDEP], 2000) and the Federal Facility and Consent Order (FFACO) (NDEP et al., 1996). CAU 110 consists of one Corrective Action Site 03-23-04, described as the U-3ax/bl Subsidence Crater. Certifications of closure are located in Appendix A. The U-3ax/bl is a historic disposal unit within the Area 3 RWMS located on the Nevada Test Site (NTS). The unit, which was formed by excavating the area between two subsidence craters (U-3ax and U-3bl), was operationally closed in 1987. The U-3ax/bl disposal unit was closed under the RCRA, as a hazardous waste landfill. Existing records indicate that, from July 1968 to December 1987, U-3ax/bl received 2.3 x 10{sup 5} cubic meters (m{sup 3}) (8.12 x 10{sup 6} cubic feet [ft{sup 3}]) of waste. NTS atmospheric nuclear device testing generated approximately 95% of the total waste volume disposed of in U-3ax/bl; 80% of the total volume was generated from the Waste Consolidation Project. Area 3 is located in Yucca Flat, within the northeast quadrant of the NTS. The Yucca Flat watershed is a structurally closed basin encompassing an area of approximately 780 square kilometers (300 square miles). The structural geomorphology of Yucca Flat is typical of the Basin and Range Physiographic Province. Yucca Flat lies in one of the most arid regions of the country. Water balance calculations for Area 3 indicate that it is normally in a state of moisture deficit.

  12. Testing Solutions for Adult Film Performers.

    Science.gov (United States)

    Bergman, Zachary R

    2014-01-01

    The majority of the nation's adult films are produced in California, and within California, most production occurs in Los Angeles. In order to regulate that content, the County of Los Angeles passed the Safer Sex in the Adult Film Industry Act (Measure B) by way of referendum in November 2012. Measure B requires that adult film producers wishing to film in Los Angeles County obtain permits from the Los Angeles County Department of Public Health, and it also mandates that adult film performers use condoms while filming and "engaging in anal or vaginal sexual intercourse." Nevertheless, between August 2013 and January 2014, several adult film performers in California tested positive for HIV, and the threat of infection remains. Although Measure B is not the best way forward for Los Angeles County, elements of the ordinance should be incorporated into future legislative efforts. Given the economic ramifications of industry flight due to more localized regulations, this Note concludes that California should pass statewide comprehensive reform. Any such new legislation must treat "independent contractors," the classification generally used for adult film performs, as if they were regular employees. Legislation should also couple mandatory testing mechanisms with provisions granting performers the right to choose whether they use condoms. Finally, legislation must include mechanisms that ensure performers' preferences are not improperly tainted by outside forces and pressures. While there will always be risks associated with the production of adult content, if undertaken, these reforms could significantly mitigate those hazards.

  13. Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 408: Bomblet Target Area Tonopah Test Range (TTR), Nevada, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Mark Krauss

    2010-03-01

    This Streamlined Approach for Environmental Restoration Plan addresses the actions needed to achieve closure of Corrective Action Unit (CAU) 408, Bomblet Target Area (TTR). Corrective Action Unit 408 is located at the Tonopah Test Range and is currently listed in Appendix III of the Federal Facility Agreement and Consent Order. Corrective Action Unit 408 comprises Corrective Action Site TA-55-002-TAB2, Bomblet Target Areas. Clean closure of CAU 408 will be accomplished by removal of munitions and explosives of concern within seven target areas and potential disposal pits. The target areas were used to perform submunitions related tests for the U.S. Department of Energy (DOE). The scope of CAU 408 is limited to submunitions released from DOE activities. However, it is recognized that the presence of other types of unexploded ordnance and munitions may be present within the target areas due to the activities of other government organizations. The CAU 408 closure activities consist of: • Clearing bomblet target areas within the study area. • Identifying and remediating disposal pits. • Collecting verification samples. • Performing radiological screening of soil. • Removing soil containing contaminants at concentrations above the action levels. Based on existing information, contaminants of potential concern at CAU 408 include unexploded submunitions, explosives, Resource Conservation Recovery Act metals, and depleted uranium. Contaminants are not expected to be present in the soil at concentrations above the action levels; however, this will be determined by radiological surveys and verification sample results.

  14. Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 408: Bomblet Target Area Tonopah Test Range (TTR), Nevada, Revision 1

    International Nuclear Information System (INIS)

    Krauss, Mark

    2010-01-01

    This Streamlined Approach for Environmental Restoration Plan addresses the actions needed to achieve closure of Corrective Action Unit (CAU) 408, Bomblet Target Area (TTR). Corrective Action Unit 408 is located at the Tonopah Test Range and is currently listed in Appendix III of the Federal Facility Agreement and Consent Order. Corrective Action Unit 408 comprises Corrective Action Site TA-55-002-TAB2, Bomblet Target Areas. Clean closure of CAU 408 will be accomplished by removal of munitions and explosives of concern within seven target areas and potential disposal pits. The target areas were used to perform submunitions related tests for the U.S. Department of Energy (DOE). The scope of CAU 408 is limited to submunitions released from DOE activities. However, it is recognized that the presence of other types of unexploded ordnance and munitions may be present within the target areas due to the activities of other government organizations. The CAU 408 closure activities consist of: (1) Clearing bomblet target areas within the study area. (2) Identifying and remediating disposal pits. (3) Collecting verification samples. (4) Performing radiological screening of soil. (5) Removing soil containing contaminants at concentrations above the action levels. Based on existing information, contaminants of potential concern at CAU 408 include unexploded submunitions, explosives, Resource Conservation Recovery Act metals, and depleted uranium. Contaminants are not expected to be present in the soil at concentrations above the action levels; however, this will be determined by radiological surveys and verification sample results.

  15. Surry Power Station, Units 1 and 2. Annual operating report for 1976, section 2: core performance and startup physics test reports

    International Nuclear Information System (INIS)

    1977-01-01

    The analyses of four core performance indicators including burnup distribution, reactivity depletion, power distribution, and primary coolant activity are discussed. Information is presented concerning fuel densification monitoring; start-up physics testing; and James River temperature, salinity, fish, biota, and plankton entrainment monitoring

  16. Preoperation of Hamaoka Nuclear Power Station Unit No. 4

    International Nuclear Information System (INIS)

    Fukuyo, Tadashi; Kurata, Satoshi

    1994-01-01

    Chubu Electric Power Co. finished preoperation of Hamaoka Nuclear Power Station Unit No. 4 in September, 1993. Although unit 4 has the same reactor design as unit 3, its rated electrical output (1,137MW) is 37MW more than that of unit 3. This increase was achieved mainly by adopting a Moisture Separater Heater in the turbine system. We started preoperation of unit 4 in November 1992 and performed various tests at electrical outputs of 20%, 50%, 75%, and 100%. We finished preoperation without any scram or other major problems and obtained satisfactory results for the functions and performance of the plant. This paper describes the major results of unit 4 preoperation. (author)

  17. A Framework for Fully Automated Performance Testing for Smart Buildings

    DEFF Research Database (Denmark)

    Markoska, Elena; Johansen, Aslak; Lazarova-Molnar, Sanja

    2018-01-01

    , setup of performance tests has been manual and labor-intensive and has required intimate knowledge of buildings’ complexity and systems. The emergence of the concept of smart buildings has provided an opportunity to overcome this restriction. In this paper, we propose a framework for automated......A significant proportion of energy consumption by buildings worldwide, estimated to ca. 40%, has yielded a high importance to studying buildings’ performance. Performance testing is a mean by which buildings can be continuously commissioned to ensure that they operate as designed. Historically...... performance testing of smart buildings that utilizes metadata models. The approach features automatic detection of applicable performance tests using metadata queries and their corresponding instantiation, as well as continuous commissioning based on metadata. The presented approach has been implemented...

  18. Test Operations Procedure (TOP) 08-2-188 Chemical Point Detector Vapor Testing

    Science.gov (United States)

    2018-04-27

    Final 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Test Operations Procedure (TOP) 08-2-188 Chemical Point Detector Vapor Testing 5a. CONTRACT...NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING...ORGANIZATION NAME(S) AND ADDRESS(ES) US Army Dugway Proving Ground West Desert Test Center (TEDT-DPW) Dugway, UT 84022-5000 8. PERFORMING ORGANIZATION

  19. COTRANSA simulation of Chinshan unit one generator load rejection test

    International Nuclear Information System (INIS)

    Wu, C.H.

    1984-01-01

    A simulation of the plant behavior during a BWR generator load rejection transient using Exxon Nuclear Company's COTRANSA code is presented in this paper. The results are compared to measurements obtained by Taiwan Power Company during a generator load rejection transient, initiated at full power condition, which was one of the Chinshan Unit 1 initial cycle startup tests. Good agreement between the COTRANSA predicted and the measured values, indicates that the COTRANSA code can simulate this transient satisfactorily

  20. The Relationship between Tests of Neurocognition and Performance on a Laparoscopic Simulator

    Directory of Open Access Journals (Sweden)

    Oumar Kuzbari

    2010-01-01

    Full Text Available Objective. To estimate if there is a relationship between the results of tests of neurocognition and performance on a laparoscopic surgery simulator. Methods and Materials. Twenty participants with no prior laparoscopic experience had baseline cognitive tests administered (Trail Making Test, Part A and B (TMT-A and TMT-B, Grooved Peg Board Test, Symbol Digit Modalities Test, Symbol Digit Recall Test, and Stroop Interference Test, completed a demographic questionnaire, and then performed laparoscopy using a simulator. We correlated the results of cognitive tests with laparoscopic surgical performance. Results. One cognitive test sensitive to frontal lobe function, TMT-A, significantly correlated with laparoscopic surgical performance on the simulator (correlation coefficient of 0.534 with P<.05. However, the correlation between performance and other cognitive tests (TMT-B, Grooved Peg Board Test, Symbol Digit Modalities Test, Symbol Digit Recall Test, and Stroop Interference Test was not statistically significant. Conclusion. Laparoscopic performance may be related to measures of frontal lobe function. Neurocognitive tests may predict motor skills abilities and performance on laparoscopic simulator.

  1. Performance tests of an abrasive cut-off systems for the finishing of high-precision casts

    Directory of Open Access Journals (Sweden)

    A. Fedoryszyn

    2008-10-01

    Full Text Available The paper summarizes the performance data of a newly designed and engineered grinding and cut-off system. The machine is used forseparation of models manufactured by the investment casting method. The machine comprises the following units:- base supporting other assemblies and elements: abrasive disc holder and drives; this solution enables an easy replacement and access toholding elements while a belt transmission allows the disc rpm to be varied,- mechanism moving the spindle in the horizontal, hence the abrasive disc position with respect to the batch can be precisely controlled,depending on the cast position and their shape,- holding and positioning-control of the batch to enable the fore and aft movements and rotations,- guide systems ensuring the travel of the batch in the specified direction and adjusting the travel speed to the required cutting rate,- centering, control, exhaust system, housing.Extensive tests were performed, including the tests of operating parameters of abrasive discs depending on the cast material, cyclograms ofthe applied treatment are obtained accordingly.

  2. Performance tests of an abrasive cut-off systems for the finishing of high-precision casts

    Directory of Open Access Journals (Sweden)

    A. Fedoryszyn

    2008-07-01

    Full Text Available The paper summarizes the performance data of a newly designed and engineered grinding and cut-off system. The machine is used for separation of models manufactured by the investment casting method. The machine comprises the following units:- base supporting other assemblies and elements: abrasive disc holder and drives; this solution enables an easy replacement and access to holding elements while a belt transmission allows the disc rpm to be varied,- mechanism moving the spindle in the horizontal, hence the abrasive disc position with respect to the batch can be precisely controlled, depending on the cast position and their shape,- holding and positioning-control of the batch to enable the fore and aft movements and rotations,- guide systems ensuring the travel of the batch in the specified direction and adjusting the travel speed to the required cutting rate,- centering, control, exhaust system, housingExtensive tests were performed, including the tests of operating parameters of abrasive discs depending on the cast material, cyclograms of the applied treatment are obtained accordingly.

  3. The study of the energetic performance in test cycles

    Science.gov (United States)

    Rentea, Cristian; Tuca, Alexandra; Oprean, Mircea; Marius, Bataus

    2017-10-01

    One of the most important subsystems of modern passenger cars is the transmission. This paper aims to investigate the global performances of a modern transmission in different test cycles including the newly introduced WLTC (Worldwide Harmonized Light Vehicles Test Cycle). The study is done using a complex model developed in a performant simulation environment. Transmission efficiency calculation is emphasized, the efficiency being considered variable depending on engine torque, engine speed and gear ratio. The main important parameters (vehicle speed fluctuation, overall transmission efficiency, fuel consumption ratio) needed to compare test cycles and the transmissions performance are determined.

  4. Verification Test of Hydraulic Performance for Reactor Coolant Pump

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Jun; Kim, Jae Shin; Ryu, In Wan; Ko, Bok Seong; Song, Keun Myung [Samjin Ind. Co., Seoul (Korea, Republic of)

    2010-01-15

    According to this project, basic design for prototype pump and model pump of reactor coolant pump and test facilities has been completed. Basic design for prototype pump to establish structure, dimension and hydraulic performance has been completed and through primary flow analysis by computational fluid dynamics(CFD), flow characteristics and hydraulic performance have been established. This pump was designed with mixed flow pump having the following design requirements; specific velocity(Ns); 1080.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 3115m{sup 3}/h, total head ; 26.3m, pump speed; 1710rpm, pump efficiency; 77.0%, Impeller out-diameter; 349mm, motor output; 360kw, design pressure; 17MPaG. The features of the pump are leakage free due to no mechanical seal on the pump shaft which insures reactor's safety and law noise level and low vibration due to no cooling fan on the motor which makes eco-friendly product. Model pump size was reduced to 44% of prototype pump for the verification test for hydraulic performance of reactor coolant pump and was designed with mixed flow pump and canned motor having the following design requirements; specific speed(NS); 1060.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 539.4m{sup 3}/h, total head; 21.0m, pump speed; 3476rpm, pump efficiency; 72.9%, Impeller out-diameter; 154mm, motor output; 55kw, design pressure; 1.0MPaG. The test facilities were designed for verification test of hydraulic performance suitable for pump performance test, homologous test, NPSH test(cavitation), cost down test and pressure pulsation test of inlet and outlet ports. Test tank was designed with testing capacity enabling up to 2000m{sup 3}/h and design pressure 1.0MPaG. Auxiliary pump was designed with centrifugal pump having capacity; 1100m{sup 3}/h, total head; 42.0m, motor output; 190kw

  5. Full-Scale Dynamic Testing of Dolosse to Destruction

    DEFF Research Database (Denmark)

    Burcharth, Hans F.

    1981-01-01

    It is well known that the relative dynamic strength of unreinforced slender concrete units decreases as the size increases. Big units can resist relatively smaller movements than small units. When model tests of cover layer stability are performed the determination of the damage criterion....... The set up and the procedure of the tests, which simulate the impact from rocking of the units and from concrete pieces that are thrown against the units, are designed to make a comparison between the behaviour of units of different sizes possible. The test method is described and proposed as a standard...... exists. Different ways of improving the strength of the units are discussed on the basis of the results from tests with different types of concrete. The tests included an investigation of the influence of reinforcement, and of different types of concrete and surface cracks on the strength of the units....

  6. Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Buttner, William J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hartmann, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Schmidt, Kara [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cebolla, Rafeal O [Joint Research Centre, Petten, the Netherlands; Weidner, Eveline [Joint Research Centre, Petten, the Netherlands; Bonato, Christian [Joint Research Centre, Petten, the Netherlands

    2017-11-06

    Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of

  7. Testing prospect theory in students’ performance

    OpenAIRE

    Pérez Galdón, Patricia; Nicolau, Juan Luis

    2013-01-01

    This paper tests the existence of ‘reference dependence’ and ‘loss aversion’ in students’ academic performance. Accordingly, achieving a worse than expected academic performance would have a much stronger effect on students’ (dis)satisfaction than obtaining a better than expected grade. Although loss aversion is a well-established finding, some authors have demonstrated that it can be moderated – diminished, to be precise–. Within this line of research, we also examine whether the students’ e...

  8. Development of performance tests for an automated MC and A system

    International Nuclear Information System (INIS)

    Kok, K.D.; Klingensmith, R.W.; Riffle, W.; Carver, R.D.; Schumacher, S.S.; Lavender, J.C.; Smith, B.W.

    1988-01-01

    Performance tests of MC and A systems using computers are described, and some example scenarios are discussed. Facility personnel or an external inspection group may use performance tests to evaluate MC and A capabilities under actual operating conditions. This paper addresses test elements common to both user groups. Performance tests consist of scenario development, security, and safety measures, conduct, and evaluation. Because exercises often test scenarios against which the MC and A system is protecting, they may require additional security and safety measures. Computer systems enhance MC and A by providing greater speed, increased precision, and automated checks. Performance tests for MC and A systems using computers differ from performance tests employing manual data systems in that the scenarios must anticipate computer actions rather than utilize controllers to adjust the scenario

  9. Final report for the 5th surveillance test of the reactor pressure vessel material (capsule Y) of Yonggwang Nuclear Power Plant unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sam Lai; Kim, ByoungChul; Chang, Kee Ok (and others)

    2006-02-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Daejeon after the capsule was transported from Yonggwang site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X, W and Y are 5.777E+18, 1.5371E+19, 3.7634E+19, 4.3045E+19, and 4.8662E+19n/cm{sup 2}, respectively. The bias factor, the ratio of calculation/measurement, was 0.953 for the 1st through 5th testing and the calculational uncertainty,7.2% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.659E+19n/cm{sup 2} based on the end of 13th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 48, 56 and 64EFPY would reach 3.625E+19, 5.293E+19, 6.127E+19 and 6.960E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 2 showed that there would be no problem for the Pressurized Thermal Shock(PTS) during the operation until design life.

  10. Preliminary test of remote manual instrumentation & control type system for vacuum unit of 350 KeV / 10 mA electron beam machine

    International Nuclear Information System (INIS)

    Sudiyanto

    2003-01-01

    Remote manual instrumentation & control type for vacuum unit of 350 KeV/10 mA Electron Beam Machine is being completed. The system consisting of a remote manual controlled and a remote acquisition system. A remote manual (50 m) controlled is based on the on/off status of 220 Volt terminal supply for pneumatic valves and vacuum pumps, in this case the power supply switch of pneumatic valves and pumps have already been selected On. Remote acquisition of vacuum level can be done by using a CCTV camera which is place in front of the panning gauge and TGP.300 Balzer unit.The CCTV system equipped with 6 cameras, one TV monitor and a multiplexer unit to arranged a selected picture on it. One of the camera was mounted on the rotator unit, it can be controlled (rotating left / right) for different monitoring orientations required by using infrared controller. A trial test of the remote manual control system for vacuum unit of the Electron Beam Machine showed a good performance. (author)

  11. Dynamic Performance Characteristic Tests of Real Scale Lead Rubber Bearing for the Evaluation of Performance Criteria

    International Nuclear Information System (INIS)

    Kim, Min Kyu; Kim, Jung-Han; Choi, In-Kil

    2014-01-01

    Dynamic characteristic tests of full scale lead rubber bearing were performed for the evaluation of performance criteria of isolation system for nuclear power plants. For the dynamic test for a full scale rubber bearing, two 1500mm diameter lead rubber bearings were manufactured. The viewpoints of this dynamic test are determination of an ultimate shear strain level of lead rubber bearing, behavior of rubber bearing according to static and dynamic input motion, sinusoidal and random (earthquake) motion, and 1-dimentional and 2-dimensional input motion. In this study, seismic isolation device tests were performed for the evaluation of performance criteria of isolation system. Through this test, it can be recognized that in the case of considering a mechanical property test, dynamic and multi degree of loading conditions should be determined. But these differences should be examined how much affect to the global structural behavior

  12. The effects of unit morale and interpersonal relations on conflict in the nursing unit.

    Science.gov (United States)

    Cox, K B

    2001-07-01

    Health care organizations face major changes, and these changes are likely to increase conflict in organizations. Although numerous studies have focused on conflict management, few have considered causes and effect of conflict in nursing units. The investigation tested a structural equation that examined the relationships among individual and contextual variables and intragroup conflict, job satisfaction, team performance effectiveness, and anticipated turnover. The nonrandom sample consisted of 141 nurses employed on 13 inpatient units at a state-supported, 597-bed academic medical centre in a southeastern city. Intragroup conflict was higher on smaller units with a higher ratio of RNs to total staff. Intragroup conflict was not associated with satisfaction with pay or anticipated turnover. In the final model, the unit morale and interpersonal relations dimension of team performance effectiveness was negatively associated with intragroup conflict and anticipated turnover, and positively associated with satisfaction with pay. High perceptions of unit morale and interpersonal relations buffered the effect of unit size and skill mix on intragroup conflict. Goodness of fit statistics indicated a good fit of the model to data. The findings have implications for nursing educators and administrators, and provide direction for future research.

  13. United States and European students’ social-networking site activities and academic performance

    NARCIS (Netherlands)

    Karpinski, Aryn; Kirschner, Paul A.; Shreffler, Anthony; Albert, Patricia; Tomko, Carrie

    2018-01-01

    Different cultures communicate differently. Research is beginning to examine the differences in culture related to social-networking site (SNS) use. Differences in specific SNS activities related to academic performance among United States (US; n = 446) and European (n = 394) university students

  14. Performance test of a ceramic turbo-viscous pump

    International Nuclear Information System (INIS)

    Abe, Tetsuya; Hiroki, Seiji; Murakami, Yoshio; Shiraishi, Shigeyuki; Totoura, Sadayuki; Ohtaki, Takashi.

    1994-01-01

    In the special fields of nuclear fusion facilities and semiconductor production installation, the development of new vacuum pumps which can cope with strong magnetic fields, high temperature gas and corrosive gas is demanded. Mitsubishi Heavy Industries Ltd. has advanced the development of ceramic turbo-molecular pumps and ceramic turbo-viscous pumps, which use ceramic rotors and gas bearings since 1985. The evaluation test of the ceramic turbo-viscous vacuum pump CT-3000H which can evacuate from atmospheric pressure to high vacuum with one pump was carried out, and the experimental results on the performance and the reliability were obtained, therefore, those are reported in this paper. The structure, specification and features of the CT-3000H are shown. The exhaust performance test of the pump was carried out in conformity with the standard of the Vacuum Society of Japan, JVIS 005 'Method of performance test for turbo-molecular pumps'. The gases used were nitrogen and helium. The results are shown. The exhaust test from atmospheric pressure was carried out by two methods, and the results are shown. (K.I.)

  15. Development and experimental testing of a hybrid Stirling engine-adsorption chiller auxiliary power unit for heavy trucks

    International Nuclear Information System (INIS)

    Flannery, Barry; Lattin, Robert; Finckh, Oliver; Berresheim, Harald; Monaghan, Rory F.D.

    2017-01-01

    Highlights: • Free-piston Stirling engine for truck APU. • Waste heat driven adsorption chiller for cab air conditioning. • Reduced-order model comparing proposed system to existing technology. • Experimental test data from prototype test rig. - Abstract: This paper identifies the key technical requirements for a heavy truck auxiliary power unit (APU) and explores a potential alternative technology for use in a next-generation APU which could eliminate key problems related to emissions, noise and maintenance experienced today by conventional diesel engine-vapour compression APUs. The potential performance of a novel hybrid Stirling engine-adsorption chiller concept is investigated and benchmarked against the incumbent technology using a reduced-order model based on experimental data. Experimental results from a Stirling-adsorption system (SAS) prototype test rig are also presented which highlight system integration dynamics and overall performance. The adsorption chiller achieved an average COP of 0.42 ± 0.06 and 2.3 ± 0.1 kW_t of cooling capacity at the baseline test condition. The prototype SAS test rig demonstrates that there appear to be no major technology barriers remaining that would prevent adoption of the SAS concept in a next-generation APU. Such a system could offer a reduction of exhaust emissions, greenhouse gases (GHG), ozone-depleting substances, noise, low maintenance and the potential for fuel flexibility and higher reliability. Preliminary modelling results indicate that the proposed system could offer superior overall electrical and cooling efficiencies compared to incumbent APUs and demonstrate a payback period of 4.6 years.

  16. Test results of the signal processing and amplifier unit for the emittance measurement system

    International Nuclear Information System (INIS)

    Stawiszynski, L.; Schneider, S.

    1984-01-01

    The signal processing and amplifier unit for the emittance measurement system is the unit with which the beam current on the harp-wires and the slit is measured and converted to a digital output. Temperature effects are very critical at low currents and the purpose of the test measurements described in this report was mainly to establish the accuracy and repeatability of the measurements under the influence of temperature variations

  17. Development of a grinding-specific performance test set-up

    DEFF Research Database (Denmark)

    Olesen, C. G.; Larsen, B. H.; Andresen, E. L.

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding...... demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding...... and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding...

  18. Unit evaluation at Yucca Mountain, Nevada Test Site: summary report and recommendation

    International Nuclear Information System (INIS)

    Johnstone, J.K.; Peters, R.R.; Gnirk, P.F.

    1984-06-01

    Of the four potential repository units, identified at Yucca Mountain, two potential units the welded, devitrified portions of the Bullfrog and Tram Members of the Crater Flat Tuff are below the water table. The welded, devitrified Topopah Spring Member of the Paintbrush Tuff and the nonwelded, zeolitized Tuffaceous Beds of Calico Hills are above the water table. The results of a study of the four potential repository units are to provide a technical basis for selecting a single target repository unit for future test and evaluation. The unit evaluation studies compared the units rather than provided and absolute assessment. The four ranking evaluation criteria used were: radionuclide isolation time; allowable repository gross thermal loading; excavation stability; and relative economics. Considered the most important of the criteria as well as the most difficult, radionuclide isolation times were estimated using the limited existing data. The allowable repository gross thermal loadings determined from near-field calculations, were nearly the same for all four units. The gross thermal loading supported other criteria by providing the heat source for succeeding thermally related evaluation studies. A large number of studies evaluated excavation stability, including near-field mechanical and thermomechanical finite element code calculations studies. A large number of studies evaluated excavation stability, including near-field mechanical and thermomechanical finite element code calculations, rock matrix property evaluation, and rock mass classification. Relative economics, a minor criterion, did not play an explicit role in the final ranking. Based on all of the analyses, the final recommendation was that the Topopah Springs be selected as the target unit, followed, in order, by the Calico Hills, Bullfrog, and Tram

  19. Performance Testing Methodology for Safety-Critical Programmable Logic Controller

    International Nuclear Information System (INIS)

    Kim, Chang Ho; Oh, Do Young; Kim, Ji Hyeon; Kim, Sung Ho; Sohn, Se Do

    2009-01-01

    The Programmable Logic Controller (PLC) for use in Nuclear Power Plant safety-related applications is being developed and tested first time in Korea. This safety-related PLC is being developed with requirements of regulatory guideline and industry standards for safety system. To test that the quality of the developed PLC is sufficient to be used in safety critical system, document review and various product testings were performed over the development documents for S/W, H/W, and V/V. This paper provides the performance testing methodology and its effectiveness for PLC platform conducted by KOPEC

  20. Acceptance test for 900 MWe PWR unit replacement steam generators

    International Nuclear Information System (INIS)

    Gourguechon, B.

    1993-01-01

    During the first half of 1994, the Gravelines 1 steam generators will be replaced (SG replacement procedure). The new SG's differ from the former components notably by the alloy used for the tube bundle, in this case, the high chromium content Inconel 690. So, from this standpoint, they are to be considered as PWR 900 replacement SG first models and their thermal efficiency has consequently to be assessed. This will provide an opportunity of ensuring that the performance of the components delivered is in compliance with requirements and of making the necessary provisions if significant deviations are observed. The EFMT branch, which has been in charge of the instrumentation and acceptance of the different SG first models since the first PWR plants were commissioned, will be responsible for the acceptance tests and the ultimate validation of a performance assessment procedure applicable to the future replacement steam generators. The methods and tests proposed for SG expert appraisal are based on consideration of the importance of primary measurement quality for satisfactory SG assessment and of the new test facilities with which the 900 and 1 300 PWR plants are gradually being equipped. These facilities provide an on-site computer environment for tests compatible with the tools (PATTERN, etc.) used at EFMT and in other departments. This test is the first of this kind performed by EFMT and the test facility of a nuclear power plant. (author). 6 figs