WorldWideScience

Sample records for unit technical record

  1. Laser color recording unit

    Science.gov (United States)

    Jung, E.

    1984-05-01

    A color recording unit was designed for output and control of digitized picture data within computer controlled reproduction and picture processing systems. In order to get a color proof picture of high quality similar to a color print, together with reduced time and material consumption, a photographic color film material was exposed pixelwise by modulated laser beams of three wavelengths for red, green and blue light. Components of different manufacturers for lasers, acousto-optic modulators and polygon mirrors were tested, also different recording methods as (continuous tone mode or screened mode and with a drum or flatbed recording principle). Besides the application for the graphic arts - the proof recorder CPR 403 with continuous tone color recording with a drum scanner - such a color hardcopy peripheral unit with large picture formats and high resolution can be used in medicine, communication, and satellite picture processing.

  2. Corrective Action Investigation Plan for Corrective Action Unit 536: Area 3 Release Site, Nevada Test Site, Nevada (Rev. 0 / June 2003), Including Record of Technical Change No. 1

    Energy Technology Data Exchange (ETDEWEB)

    None

    2003-06-27

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office's approach to collect the data necessary to evaluate corrective action alternatives (CAAs) appropriate for the closure of Corrective Action Unit (CAU) 536: Area 3 Release Site, Nevada Test Site, Nevada, under the Federal Facility Agreement and Consent Order. Corrective Action Unit 536 consists of a single Corrective Action Site (CAS): 03-44-02, Steam Jenny Discharge. The CAU 536 site is being investigated because existing information on the nature and extent of possible contamination is insufficient to evaluate and recommend corrective action alternatives for CAS 03-44-02. The additional information will be obtained by conducting a corrective action investigation (CAI) prior to evaluating CAAs and selecting the appropriate corrective action for this CAS. The results of this field investigation are to be used to support a defensible evaluation of corrective action alternatives in the corrective action decision document. Record of Technical Change No. 1 is dated 3-2004.

  3. Corrective Action Investigation Plan for Corrective Action Unit 516: Septic Systems and Discharge Points, Nevada Test Site, Nevada, Rev. 0, Including Record of Technical Change No. 1

    Energy Technology Data Exchange (ETDEWEB)

    None

    2003-04-28

    This Corrective Action Investigation Plan (CAIP) contains the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Sites Office's (NNSA/NSO's) approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 516, Septic Systems and Discharge Points, Nevada Test Site (NTS), Nevada, under the Federal Facility Agreement and Consent Order. CAU 516 consists of six Corrective Action Sites: 03-59-01, Building 3C-36 Septic System; 03-59-02, Building 3C-45 Septic System; 06-51-01, Sump Piping, 06-51-02, Clay Pipe and Debris; 06-51-03, Clean Out Box and Piping; and 22-19-04, Vehicle Decontamination Area. Located in Areas 3, 6, and 22 of the NTS, CAU 516 is being investigated because disposed waste may be present without appropriate controls, and hazardous and/or radioactive constituents may be present or migrating at concentrations and locations that could potentially pose a threat to human health and the environment. Existing information and process knowledge on the expected nature and extent of contamination of CAU 516 are insufficient to select preferred corrective action alternatives; therefore, additional information will be obtained by conducting a corrective action investigation. The results of this field investigation will support a defensible evaluation of corrective action alternatives in the corrective action decision document. Record of Technical Change No. 1 is dated 3/2004.

  4. [Technical record in radiotherapy (author's transl)].

    Science.gov (United States)

    Le Dorze, C; Horiot, J C; Laugier, A

    1977-11-01

    The term "technical record in radiotherapy" is used to describe collected information relative to treatment using radiation. The subject of this session of the chapter of Radiotherapy of the Société Française de Radiologie was the intrinsic functions of this record and its extrinsic limitations. The extreme diversity of the current state of the record is a known fact. A majority of participants express the desire for uniformisation of the collection of data or even, as a second stage, to have a common record. A library of technical records was set up under the responsibility of the Centre Georges-François Leclerc at Dijon (J.C. Horiot). One broad conclusion was seen to emerge: the creation of a minimum common record including essential information to which could be added the more specific data of each radiotherapist and at each time of use. Prior agreement will be necessary with regard to the standardisation of apparatus and the expression of the dose. This session was of necessity merely a reflection of future needs and it is to be hoped that the good will which was obvious during the course of the discussion may produce concrete results in the months to come.

  5. Corrective Action Investigation Plan for Corrective Action Unit 490: Station 44 Burn Area, Tonopah Test Range, Nevada (with Record of Technical Change No.1)

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Nevada Operations Office

    2000-06-09

    This Corrective Action Investigation Plan (CAIP) contains the U.S. Department of Energy, Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 490 under the Federal Facility Agreement and Consent Order. Corrective Active Unit 490 consists of four Corrective Action Sites (CASs): 03-56-001-03BA, Fire Training Area (FTA); RG-56-001-RGBA, Station 44 Burn Area; 03-58-001-03FN, Sandia Service Yard; and 09-54-001-09L2, Gun Propellant Burn Area. These CASs are located at the Tonopah Test Range near Areas 3 and 9. Historically, the FTA was used for training exercises where tires and wood were ignited with diesel fuel. Records indicate that water and carbon dioxide were the only extinguishing agents used during these training exercises. The Station 44 Burn Area was used for fire training exercises and consisted of two wooden structures. The two burn areas (ignition of tires, wood, and wooden structures with diesel fuel and water) were limited to the building footprints (10 ft by 10 ft each). The Sandia Service Yard was used for storage (i.e., wood, tires, metal, electronic and office equipment, construction debris, and drums of oil/grease) from approximately 1979 to 1993. The Gun Propellant Burn Area was used from the 1960s to 1980s to burn excess artillery gun propellant, solid-fuel rocket motors, black powder, and deteriorated explosives; additionally, the area was used for the disposal of experimental explosive items. Based on site history, the focus of the field investigation activities will be to: (1) determine the presence of contaminants of potential concern (COPCs) at each CAS, (2) determine if any COPCs exceed field-screening levels and/or preliminary action levels, and (3) determine the nature and extent of contamination with enough certainty to support selection of corrective action alternatives for each CAS. The scope of this CAIP is to resolve

  6. Technical records as material evidence in criminal proceedings

    OpenAIRE

    Fitim Shishani

    2017-01-01

    Nowadays, with the aid of technical records - recordings (audio, visual or combined audiovisual) events and occurrences can be registered in the outside world in detail. The recording enables the creator or anyone who has it in disposal that at any moment of its reproduction, it can be found in detail how the recorded event has happened or how an occurrence seemed at the time of the recording. Among the current formats of technical records are included: photography, filming, magnetic, magneto...

  7. Corrective Action Investigation Plan for Corrective Action Unit 168: Areas 25 and 26 Contaminated Materials and Waste Dumps, Nevada Test Site, Nevada (Rev. 0) includes Record of Technical Change No. 1 (dated 8/28/2002), Record of Technical Change No. 2 (dated 9/23/2002), and Record of Technical Change No. 3 (dated 6/2/2004)

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada

    2001-11-21

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office's approach to collect data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit 168 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 168 consists of a group of twelve relatively diverse Corrective Action Sites (CASs 25-16-01, Construction Waste Pile; 25-16-03, MX Construction Landfill; 25-19-02, Waste Disposal Site; 25-23-02, Radioactive Storage RR Cars; 25-23-18, Radioactive Material Storage; 25-34-01, NRDS Contaminated Bunker; 25-34-02, NRDS Contaminated Bunker; CAS 25-23-13, ETL - Lab Radioactive Contamination; 25-99-16, USW G3; 26-08-01, Waste Dump/Burn Pit; 26-17-01, Pluto Waste Holding Area; 26-19-02, Contaminated Waste Dump No.2). These CASs vary in terms of the sources and nature of potential contamination. The CASs are located and/or associated wit h the following Nevada Test Site (NTS) facilities within three areas. The first eight CASs were in operation between 1958 to 1984 in Area 25 include the Engine Maintenance, Assembly, and Disassembly Facility; the Missile Experiment Salvage Yard; the Reactor Maintenance, Assembly, and Disassembly Facility; the Radioactive Materials Storage Facility; and the Treatment Test Facility Building at Test Cell A. Secondly, the three CASs located in Area 26 include the Project Pluto testing area that operated from 1961 to 1964. Lastly, the Underground Southern Nevada Well (USW) G3 (CAS 25-99-16), a groundwater monitoring well located west of the NTS on the ridgeline of Yucca Mountain, was in operation during the 1980s. Based on site history and existing characterization data obtained to support the data quality objectives process, contaminants of potential concern (COPCs) for CAU 168 are primarily radionuclide; however, the COPCs for several CASs were not defined. To address COPC

  8. Corrective Action Investigation Plan for Corrective Action Unit 168: Areas 25 and 26 Contaminated Materials and Waste Dumps, Nevada Test Site, Nevada (Rev. 0) includes Record of Technical Change No. 1 (dated 8/28/2002), Record of Technical Change No. 2 (dated 9/23/2002), and Record of Technical Change No. 3 (dated 6/2/2004)

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada

    2001-11-21

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office's approach to collect data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit 168 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 168 consists of a group of twelve relatively diverse Corrective Action Sites (CASs 25-16-01, Construction Waste Pile; 25-16-03, MX Construction Landfill; 25-19-02, Waste Disposal Site; 25-23-02, Radioactive Storage RR Cars; 25-23-18, Radioactive Material Storage; 25-34-01, NRDS Contaminated Bunker; 25-34-02, NRDS Contaminated Bunker; CAS 25-23-13, ETL - Lab Radioactive Contamination; 25-99-16, USW G3; 26-08-01, Waste Dump/Burn Pit; 26-17-01, Pluto Waste Holding Area; 26-19-02, Contaminated Waste Dump No.2). These CASs vary in terms of the sources and nature of potential contamination. The CASs are located and/or associated wit h the following Nevada Test Site (NTS) facilities within three areas. The first eight CASs were in operation between 1958 to 1984 in Area 25 include the Engine Maintenance, Assembly, and Disassembly Facility; the Missile Experiment Salvage Yard; the Reactor Maintenance, Assembly, and Disassembly Facility; the Radioactive Materials Storage Facility; and the Treatment Test Facility Building at Test Cell A. Secondly, the three CASs located in Area 26 include the Project Pluto testing area that operated from 1961 to 1964. Lastly, the Underground Southern Nevada Well (USW) G3 (CAS 25-99-16), a groundwater monitoring well located west of the NTS on the ridgeline of Yucca Mountain, was in operation during the 1980s. Based on site history and existing characterization data obtained to support the data quality objectives process, contaminants of potential concern (COPCs) for CAU 168 are primarily radionuclide; however, the COPCs for several CASs were not defined. To address COPC

  9. Technical records as material evidence in criminal proceedings

    Directory of Open Access Journals (Sweden)

    Fitim Shishani

    2017-03-01

    Full Text Available Nowadays, with the aid of technical records - recordings (audio, visual or combined audiovisual events and occurrences can be registered in the outside world in detail. The recording enables the creator or anyone who has it in disposal that at any moment of its reproduction, it can be found in detail how the recorded event has happened or how an occurrence seemed at the time of the recording. Among the current formats of technical records are included: photography, filming, magnetic, magnetoscope, and videophone recording etc. (Sahiti & Murati 2016, 295. The possibility provided by the rapid technical development is also of interest to criminal procedure because technical records containing any fact that may be proved in criminal proceedings may serve as a source of knowledge about facts. In other words, they may serve as evidence to establish facts in criminal proceedings. Given the extensive options that technical fact recordings provide, entities that use the aid of various devices from this fi eld, as well as the different purposes of the author of the recording which have led to the case of making the recording, there is a reasonable question of the permission on their use as evidence in criminal proceedings. In Kosovo, the situation is clear in terms of recordings made in the criminal procedure, as Kosovo CCP 1 provides the possibility of photographing, filming, sketching, etc., of the crime scene, audio visual recording etc. examination of persons (defendant, witness, expert or recordings of any action on judicial review.

  10. Corrective Action Decision Document for Corrective Action Unit 5: Landfills, Nevada Test Site, Nevada: Revision No. 0 (with Record of Technical Change No. 1)

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office

    2003-10-24

    This Corrective Action Decision Document identifies and rationalizes the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office's selection of a recommended corrective action alternative (CAA) appropriate to facilitate the closure of Corrective Action (CAU) 5: Landfills, Nevada Test Site (NTS), Nevada, under the Federal Facility Agreement and Consent Order. Located in Areas 5, 6, 12, 20, and 23 of the NTS, CAU 5 is comprised of eight corrective action sites (CASs). The corrective action investigation (CAI) of CAU 5 was conducted from October 7, 2002 through January 30, 2003, with geophysical surveys completed from March 6 through May 8, 2002, and topographic surveys conducted from March 11 through April 29, 2003. Contaminants of concern (COCs) were identified only at CAS 12-15-01. Those COCs included total petroleum hydrocarbons and volatile organic compounds. Based on the evaluation of analytical data from the CAI, review of future and current operations in Areas 5, 6, 12, 20, and 23 of the Nevada Test Site, and the detailed and comparative analysis of the potential CAAs, the following single alternative was developed for consideration. Close in Place with Administrative Controls is the recommended alternative for all of the CASs in CAU 5. This alternative was judged to meet all requirements for the technical components evaluated. Additionally, the alternative meets all applicable state and federal regulations for closure of the sites and will eliminate inadvertent intrusion into landfills at CAU 5.

  11. Corrective Action Investigation Plan for Corrective Action Unit 204: Storage Bunkers, Nevada Test Site, Nevada (December 2002, Revision No.: 0), Including Record of Technical Change No. 1

    Energy Technology Data Exchange (ETDEWEB)

    NNSA/NSO

    2002-12-12

    The Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 204 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 204 is located on the Nevada Test Site approximately 65 miles northwest of Las Vegas, Nevada. This CAU is comprised of six Corrective Action Sites (CASs) which include: 01-34-01, Underground Instrument House Bunker; 02-34-01, Instrument Bunker; 03-34-01, Underground Bunker; 05-18-02, Chemical Explosives Storage; 05-33-01, Kay Blockhouse; 05-99-02, Explosive Storage Bunker. Based on site history, process knowledge, and previous field efforts, contaminants of potential concern for Corrective Action Unit 204 collectively include radionuclides, beryllium, high explosives, lead, polychlorinated biphenyls, total petroleum hydrocarbons, silver, warfarin, and zinc phosphide. The primary question for the investigation is: ''Are existing data sufficient to evaluate appropriate corrective actions?'' To address this question, resolution of two decision statements is required. Decision I is to ''Define the nature of contamination'' by identifying any contamination above preliminary action levels (PALs); Decision II is to ''Determine the extent of contamination identified above PALs. If PALs are not exceeded, the investigation is completed. If PALs are exceeded, then Decision II must be resolved. In addition, data will be obtained to support waste management decisions. Field activities will include radiological land area surveys, geophysical surveys to identify any subsurface metallic and nonmetallic debris, field screening for applicable contaminants of potential concern, collection and analysis of surface and subsurface soil samples from biased locations

  12. Corrective Action Investigation Plan for Corrective Action Unit 529: Area 25 Contaminated Materials, Nevada Test Site, Nevada, Rev. 0, Including Record of Technical Change No. 1

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office

    2003-02-26

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 529, Area 25 Contaminated Materials, Nevada Test Site (NTS), Nevada, under the Federal Facility Agreement and Consent Order. CAU 529 consists of one Corrective Action Site (25-23-17). For the purpose of this investigation, the Corrective Action Site has been divided into nine parcels based on the separate and distinct releases. A conceptual site model was developed for each parcel to address the translocation of contaminants from each release. The results of this investigation will be used to support a defensible evaluation of corrective action alternatives in the corrective action decision document.

  13. Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 357: Mud Pits and Waste Dump, Nevada Test Site, Nevada: Revision 0, Including Record of Technical Change No. 1

    Energy Technology Data Exchange (ETDEWEB)

    None

    2003-06-25

    This Streamlined Approach for Environmental Restoration (SAFER) plan was prepared as a characterization and closure report for Corrective Action Unit (CAU) 357, Mud Pits and Waste Dump, in accordance with the Federal Facility Agreement and Consent Order. The CAU consists of 14 Corrective Action Sites (CASs) located in Areas 1, 4, 7, 8, 10, and 25 of the Nevada Test Site (NTS). All of the CASs are found within Yucca Flat except CAS 25-15-01 (Waste Dump). Corrective Action Site 25-15-01 is found in Area 25 in Jackass Flat. Of the 14 CASs in CAU 357, 11 are mud pits, suspected mud pits, or mud processing-related sites, which are by-products of drilling activities in support of the underground nuclear weapons testing done on the NTS. Of the remaining CASs, one CAS is a waste dump, one CAS contains scattered lead bricks, and one CAS has a building associated with Project 31.2. All 14 of the CASs are inactive and abandoned. Clean closure with no further action of CAU 357 will be completed if no contaminants are detected above preliminary action levels. A closure report will be prepared and submitted to the Nevada Division of Environmental Protection for review and approval upon completion of the field activities. Record of Technical Change No. 1 is dated 3/2004.

  14. Socio-technical considerations in epilepsy electronic patient record implementation.

    LENUS (Irish Health Repository)

    Mc Quaid, Louise

    2010-05-01

    Examination of electronic patient record (EPR) implementation at the socio-technical interface. This study was based on the introduction of an anti-epileptic drug (AED) management module of an EPR in an epilepsy out-patient clinic. The objective was to introduce the module to a live clinical setting within strictly controlled conditions to evaluate its usability and usefulness.

  15. Allocative Efficiency of Technically Inefficient Production Units

    OpenAIRE

    Bogetoft, Peter; Fare, Rolf

    1999-01-01

    We discuss how to measure allocative efficiency without presuming technical efficiency. This is relevant when it is easier to introduce reallocations than improvements of technical efficiency. We compare the approach to the traditional one of assuming technical efficiency before measuring allocative efficiency. In particular, we develop necessary and sufficient conditions on the technology to ensure consistent measures and we give dual organizational interpretations of the approaches.

  16. Major Technical Measures for Revamp of FCC Units in China

    Institute of Scientific and Technical Information of China (English)

    Li Wenjie

    2003-01-01

    FCC units are playing an important role at refineries, in particular at Chinese refineries. To cope with the current demand for better economic benefits, environmental protection and product slate adjustment, a host of FCC units need to be technically revamped. This article describes the practical processes, technologies and equipment to serve different revamp targets with analysis of two examples on revamp of commercial units.

  17. Corrective Action Investigation Plan for Corrective Action Unit 321: Area 22 Weather Station Fuel Storage, Nevada Test Site, Nevada, Revision 0. UPDATED WITH RECORD OF TECHNICAL CHANGE No.1

    Energy Technology Data Exchange (ETDEWEB)

    U.S. DOE/NV

    1999-02-08

    This Corrective Action Investigation Plan (CAIP) has been developed in accordance with the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the US Department of Energy, Nevada Operations Office (DOE/NV); the State of Nevada Division of Environmental Protection (NDEP); and the US Department of Defense (FFACO, 1996). The CAIP is a document that provides or references all of the specific information for investigation activities associated with Corrective Action Units (CAUs) or Corrective Action Sites (CASs). According to the FFACO (1996), CASs are sites potentially requiring corrective action(s) and may include solid waste management units or individual disposal or release sites. A CAU consists of one or more CASs grouped together based on geography, technical similarity, or agency responsibility for the purpose of determining corrective actions. This CAIP contains the environmental sample collection objectives and the criteria for conducting site investigation activities at the CAU 321 Area 22 Weather Station Fuel Storage, CAS 22-99-05 Fuel Storage Area. For purposes of this discussion, this site will be referred to as either CAU 321 or the Fuel Storage Area. The Fuel Storage Area is located in Area 22 of the Nevada Test Site (NTS). The NTS is approximately 105 kilometers (km) (65 miles [mi]) northwest of Las Vegas, Nevada (DOE/NV, 1996a). The Fuel Storage Area was used to store fuel and other petroleum products necessary for motorized operations at the historic Camp Desert Rock facility which was operational from 1951 to 1958 at the Nevada Test Site, Nevada. The site was dismantled after 1958 (DOE/NV, 1996a).

  18. Corrective Action Decision Document for Corrective Action Unit 168: Areas 25 and 26 Contaminated Materials and Waste Dumps, Nevada Test Site, Nevada: Revision 0, Including Record of Technical Change No. 1

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office

    2003-08-08

    This Corrective Action Decision Document identifies and rationalizes the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office's selection of recommended corrective action alternatives (CAAs) to facilitate the closure of Corrective Action Unit (CAU)168: Areas 25 and 26 Contaminated Materials and Waste Dumps, Nevada Test Site (NTS), Nevada, under the Federal Facility Agreement and Consent Order. Located in Areas 25 and 26 at the NTS in Nevada, CAU 168 is comprised of twelve Corrective Action Sites (CASs). Review of data collected during the corrective action investigation, as well as consideration of current and future operations in Areas 25 and 26 of the NTS, led the way to the development of three CAAs for consideration: Alternative 1 - No Further Action; Alternative 2 - Clean Closure; and Alternative 3 - Close in Place with Administrative Controls. As a result of this evaluation, a combination of all three CAAs is recommended for this CAU. Alternative 1 was the preferred CAA for three CASs, Alternative 2 was the preferred CAA for six CASs (and nearly all of one other CAS), and Alternative 3 was the preferred CAA for two CASs (and a portion of one other CAS) to complete the closure at the CAU 168 sites. These alternatives were judged to meet all requirements for the technical components evaluated as well as all applicable state and federal regulations for closure of the sites and elimination of potential future exposure pathways to the contaminated soils at CAU 168.

  19. Non-technical skills in the intensive care unit.

    Science.gov (United States)

    Reader, T; Flin, R; Lauche, K; Cuthbertson, B H

    2006-05-01

    In high-risk industries such as aviation, the skills not related directly to technical expertise, but crucial for maintaining safety (e.g. teamwork), have been categorized as non-technical skills. Recently, research in anaesthesia has identified and developed a taxonomy of the non-technical skills requisite for safety in the operating theatre. Although many of the principles related to performance and safety within anaesthesia are relevant to the intensive care unit (ICU), relatively little research has been done to identify the non-technical skills required for safe practice within the ICU. This review focused upon critical incident studies in the ICU, in order to examine whether the contributory factors identified as underlying the critical incidents, were associated with the skill categories (e.g. task management, teamwork, situation awareness and decision making) outlined in the Anaesthetists' Non-technical Skills (ANTS) taxonomy. We found that a large proportion of the contributory factors underlying critical incidents could be attributed to a non-technical skill category outlined in the ANTS taxonomy. This is informative both for future critical incident reporting, and also as an indication that the ANTS taxonomy may provide a good starting point for the development of a non-technical skills taxonomy for intensive care. However, the ICU presents a range of unique challenges to practitioners working within it. It is therefore necessary to conduct further non-technical skills research, using human factors techniques such as root-cause analyses, observation of behaviour, attitudinal surveys, studies of cognition, and structured interviews to develop a better understanding of the non-technical skills important for safety within the ICU. Examples of such research highlight the utility of these techniques.

  20. Receipts. Agricultural Record Keeping. Supplementary Units.

    Science.gov (United States)

    Missouri Univ., Columbia. Instructional Materials Lab.

    Eight supplementary units are included in these instructional materials for agricultural recordkeeping: (1) receipts; (2) expenditures; (3) cash flow; (4) inventory; (5) financial statement; (6) business agreements; (7) ownership business agreements; and (8) placement training agreements. Each unit contains an introduction, lesson objectives, and…

  1. The United States digital recording industry

    Science.gov (United States)

    Simonds, John L.

    1993-01-01

    The recording industry resembles the semiconductor industry in several aspects. Both are large (greater than $60 Billion/year revenues); both are considered critical technologies supporting national objectives; both are experiencing increased competition from foreign suppliers; they recognize significant opportunities for both technological and market growth in the decade to come; and both realize that a key to this future growth lies in alliances among industry, academia, and government. The semiconductor industry has made significant investments in alliances relating to manufacturing technologies (SEMATECH) and to joint long-term technology research centered in universities (SRC). The federal government has provided funding support of these efforts in recognition of the critical roles semiconductor technologies play in national interests. The recording industry is now also forming critical alliances, but has been slower in starting and in gaining broad recognition by government agencies and legislators that the industry needs federal support. Traditionally, the recording industry has been viewed as mature, stable, and, while critical to national interests, able to chart and fund its own course toward future national needs. That perception is fortunately changing.

  2. Corrective Action Investigation Plan for Corrective Action Unit 322: Areas 1 and 3 Release Sites and Injection Wells, Nevada Test Site, Nevada: Revision 0, Including Record of Technical Change No. 1

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office

    2003-07-16

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office's approach to collect the data necessary to evaluate corrective action alternatives (CAAs) appropriate for the closure of Corrective Action Unit (CAU) 322, Areas 1 and 3 Release Sites and Injection Wells, Nevada Test Site, Nevada, under the Federal Facility Agreement and Consent Order. Corrective Action Unit 322 consists of three Corrective Action Sites (CASs): 01-25-01, AST Release (Area 1); 03-25-03, Mud Plant AST Diesel Release (Area 3); 03-20-05, Injection Wells (Area 3). Corrective Action Unit 322 is being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. The investigation of three CASs in CAU 322 will determine if hazardous and/or radioactive constituents are present at concentrations and locations that could potentially pose a threat to human health and the environment. The results of this field investigation will support a defensible evaluation of corrective action alternatives in the corrective action decision document.

  3. The Human Rights Record of the United States in 2006

    Institute of Scientific and Technical Information of China (English)

    THE INFORMATION OFFICE OF THE STATE COUNCIL OF THE

    2007-01-01

    @@ EDITOR'S NOTE: On March 8, the Information Office of the State Council of the People's Republic of China published a document entitled the Human Rights Record of the United States in 2006. Following is the full text.

  4. Beowawe Bottoming Binary Unit - Final Technical Report for EE0002856

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Dale Edward

    2013-02-12

    This binary plant is the first high-output refrigeration based waste heat recovery cycle in the industry. Its working fluid is environmentally friendly and as such, the permits that would be required with a butane based cycle are not necessary. The unit is modularized, meaning that the unit’s individual skids were assembled in another location and were shipped via truck to the plant site. This project proves the technical feasibility of using low temperature brine The development of the unit led to the realization of low temperature, high output, and environmentally friendly heat recovery systems through domestic research and engineering. The project generates additional renewable energy for Nevada, resulting in cleaner air and reduced carbon dioxide emissions. Royalty and tax payments to governmental agencies will increase, resulting in reduced financial pressure on local entities. The major components of the unit were sourced from American companies, resulting in increased economic activity throughout the country.

  5. Corrective Action Investigation Plan for Corrective Action Unit 527: Horn Silver Mine, Nevada Test Site, Nevada: Revision 1 (Including Records of Technical Change No.1, 2, 3, and 4)

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office

    2002-12-06

    This Corrective Action Investigation Plan contains the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 527, Horn Silver Mine, Nevada Test Site, Nevada, under the Federal Facility Agreement and Consent Order. Corrective Action Unit 527 consists of one Corrective Action Site (CAS): 26-20-01, Contaminated Waste Dump No.1. The site is located in an abandoned mine site in Area 26 (which is the most arid part of the NTS) approximately 65 miles northwest of Las Vegas. Historical documents may refer to this site as CAU 168, CWD-1, the Wingfield mine (or shaft), and the Wahmonie mine (or shaft). Historical documentation indicates that between 1959 and the 1970s, nonliquid classified material and unclassified waste was placed in the Horn Silver Mine's shaft. Some of the waste is known to be radioactive. Documentation indicates that the waste is present from 150 feet to the bottom of the mine (500 ft below ground surface). This CAU is being investigated because hazardous constituents migrating from materials and/or wastes disposed of in the Horn Silver Mine may pose a threat to human health and the environment as well as to assess the potential impacts associated with any potential releases from the waste. The results of this field investigation will support a defensible evaluation of corrective action alternatives in the corrective action decision document.

  6. Corrective Action Investigation Plan for Corrective Action Unit 165: Areas 25 and 26 Dry Well and Washdown Areas, Nevada Test Site, Nevada (including Record of Technical Change Nos. 1, 2, and 3) (January 2002, Rev. 0)

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office (NNSA/NV)

    2002-01-09

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 165 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 165 consists of eight Corrective Action Sites (CASs): CAS 25-20-01, Lab Drain Dry Well; CAS 25-51-02, Dry Well; CAS 25-59-01, Septic System; CAS 26-59-01, Septic System; CAS 25-07-06, Train Decontamination Area; CAS 25-07-07, Vehicle Washdown; CAS 26-07-01, Vehicle Washdown Station; and CAS 25-47-01, Reservoir and French Drain. All eight CASs are located in the Nevada Test Site, Nevada. Six of these CASs are located in Area 25 facilities and two CASs are located in Area 26 facilities. The eight CASs at CAU 165 consist of dry wells, septic systems, decontamination pads, and a reservoir. The six CASs in Area 25 are associated with the Nuclear Rocket Development Station that operated from 1958 to 1973. The two CASs in Area 26 are associated with facilities constructed for Project Pluto, a series of nuclear reactor tests conducted between 1961 to 1964 to develop a nuclear-powered ramjet engine. Based on site history, the scope of this plan will be a two-phased approach to investigate the possible presence of hazardous and/or radioactive constituents at concentrations that could potentially pose a threat to human health and the environment. The Phase I analytical program for most CASs will include volatile organic compounds, semivolatile organic compounds, Resource Conservation and Recovery Act metals, total petroleum hydrocarbons, polychlorinated biphenyls, and radionuclides. If laboratory data obtained from the Phase I investigation indicates the presence of contaminants of concern, the process will continue with a Phase II investigation to define the extent of contamination. Based on the

  7. Corrective Action Investigation Plan for Corrective Action Unit 5: Landfills, Nevada Test Site, Nevada (Rev. No.: 0) includes Record of Technical Change No. 1 (dated 9/17/2002)

    Energy Technology Data Exchange (ETDEWEB)

    IT Corporation, Las Vegas, NV

    2002-05-28

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 5 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 5 consists of eight Corrective Action Sites (CASs): 05-15-01, Sanitary Landfill; 05-16-01, Landfill; 06-08-01, Landfill; 06-15-02, Sanitary Landfill; 06-15-03, Sanitary Landfill; 12-15-01, Sanitary Landfill; 20-15-01, Landfill; 23-15-03, Disposal Site. Located between Areas 5, 6, 12, 20, and 23 of the Nevada Test Site (NTS), CAU 5 consists of unlined landfills used in support of disposal operations between 1952 and 1992. Large volumes of solid waste were produced from the projects which used the CAU 5 landfills. Waste disposed in these landfills may be present without appropriate controls (i.e., use restrictions, adequate cover) and hazardous and/or radioactive constituents may be present at concentrations and locations that could potentially pose a threat to human health and/or the environment. During the 1992 to 1995 time frame, the NTS was used for various research and development projects including nuclear weapons testing. Instead of managing solid waste at one or two disposal sites, the practice on the NTS was to dispose of solid waste in the vicinity of the project. A review of historical documentation, process knowledge, personal interviews, and inferred activities associated with this CAU identified the following as potential contaminants of concern: volatile organic compounds, semivolatile organic compounds, polychlorinated biphenyls, pesticides, petroleum hydrocarbons (diesel- and gasoline-range organics), Resource Conservation and Recovery Act Metals, plus nickel and zinc. A two-phase approach has been selected to collect information and generate data to satisfy needed resolution

  8. Corrective Action Investigation Plan for Corrective Action Unit 214: Bunkers and Storage Areas Nevada Test Site, Nevada: Revision 0, Including Record of Technical Change No. 1 and No. 2

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office

    2003-05-16

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 214 under the Federal Facility Agreement and Consent Order. Located in Areas 5, 11, and 25 of the Nevada Test Site, CAU 214 consists of nine Corrective Action Sites (CASs): 05-99-01, Fallout Shelters; 11-22-03, Drum; 25-99-12, Fly Ash Storage; 25-23-01, Contaminated Materials; 25-23-19, Radioactive Material Storage; 25-99-18, Storage Area; 25-34-03, Motor Dr/Gr Assembly (Bunker); 25-34-04, Motor Dr/Gr Assembly (Bunker); and 25-34-05, Motor Dr/Gr Assembly (Bunker). These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives (CAAs). The suspected contaminants and critical analyte s for CAU 214 include oil (total petroleum hydrocarbons-diesel-range organics [TPH-DRO], polychlorinated biphenyls [PCBs]), pesticides (chlordane, heptachlor, 4,4-DDT), barium, cadmium, chronium, lubricants (TPH-DRO, TPH-gasoline-range organics [GRO]), and fly ash (arsenic). The land-use zones where CAU 214 CASs are located dictate that future land uses will be limited to nonresidential (i.e., industrial) activities. The results of this field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the corrective action decision document.

  9. Toxic Hazards Research Unit Annual Technical Report: 1984

    Science.gov (United States)

    1984-09-01

    Holland, New York, 1980. Boyd, M. R., L. T. Burka, T. M. Harris, and B. J. Wilson, (1973), Lung- toxic furanoterpenoids produced by sweet potatoes ( IPOMOEA ...AFAMRL-TR-84-00 1 NNTRI-84-41 AD-A147 857 TOXIC HAZARDS RESEARCH UNIT ANNUAL TECHNICAL REPORT: � J. D. MACEIWEN E. H. VERNOT UNIVERSITY OF...ER * BRUCE 0. s’rUART, PhD * Director Toxic Hazards Division * .Air Force Aerospace Medical Research La racory SECURITY CLASSI FICA TI0N OF THIS PAGE

  10. Rooftop Solar Photovoltaic Technical Potential in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter; Margolis, Robert; Melius, Jennifer; Phillips, Caleb; Elmore, Ryan

    2016-01-01

    How much energy could we generate if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models -- one for small buildings and one for medium and large buildings -- and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

  11. Technical standards for digital electroencephalogram recording in epilepsy practice

    Directory of Open Access Journals (Sweden)

    Nayak Dinesh

    2007-01-01

    Full Text Available With the advent of digital technology in the recording of the electroencephalogram (EEG in the last decade, analogue paper-EEG machines have all but disappeared. While there are several advantages of digital EEG over its analog counterpart, like being paperless and therefore easy to store and the ability to change montages and filter settings during review, there is wide disparity in the standards of EEG recording, display and reporting in laboratories across the country. Colorful brain maps conveying little meaning are usually appended to reports. This article reviews the minimum standards that must be observed for recording digital EEG as recommended by the International Federation of Clinical Neurophysiology (IFCN and illustrates the importance of use of appropriate derivations, montages, filters and gains during recording and review of digital EEG in the context of evaluation of patients with suspected epilepsy.

  12. Patient access to medical records on a psychiatric inpatient unit.

    Science.gov (United States)

    Stein, E J; Furedy, R L; Simonton, M J; Neuffer, C H

    1979-03-01

    The authors studied the effects of patient access to medical records during hospitalization in a psychiatric unit of a community general hospital. Questionnaires were completed by about 20 staff and 88 patients, and records were compared with those from an earlier period to note any changes in the written record. Patients reported feeling better informed and more involved in their treatment, and staff said that they became more thoughtful about their notes in the chart. The availability of staff seems crucial to this process and facilitates the working alliance.

  13. Preliminary study of technical terminology for the retrieval of scientific book metadata records

    DEFF Research Database (Denmark)

    Larsen, Birger; Lioma, Christina; Frommholz, Ingo

    2012-01-01

    Books only represented by brief metadata (book records) are particularly hard to retrieve. One way of improving their retrieval is by extracting retrieval enhancing features from them. This work focusses on scientific (physics) book records. We ask if their technical terminology can be used...

  14. Preliminary study of technical terminology for the retrieval of scientific book metadata records

    DEFF Research Database (Denmark)

    Larsen, Birger; Lioma, Christina; Frommholz, Ingo;

    2012-01-01

    Books only represented by brief metadata (book records) are particularly hard to retrieve. One way of improving their retrieval is by extracting retrieval enhancing features from them. This work focusses on scientific (physics) book records. We ask if their technical terminology can be used...... as a retrieval enhancing feature. A study of 18,443 book records shows a strong correlation between their technical terminology and their likelihood of relevance. Using this finding for retrieval yields >+5% precision and recall gains. © 2012 Authors....

  15. Quantity and unit extraction for scientific and technical intelligence analysis

    Science.gov (United States)

    David, Peter; Hawes, Timothy

    2017-05-01

    Scientific and Technical (S and T) intelligence analysts consume huge amounts of data to understand how scientific progress and engineering efforts affect current and future military capabilities. One of the most important types of information S and T analysts exploit is the quantities discussed in their source material. Frequencies, ranges, size, weight, power, and numerous other properties and measurements describing the performance characteristics of systems and the engineering constraints that define them must be culled from source documents before quantified analysis can begin. Automating the process of finding and extracting the relevant quantities from a wide range of S and T documents is difficult because information about quantities and their units is often contained in unstructured text with ad hoc conventions used to convey their meaning. Currently, even simple tasks, such as searching for documents discussing RF frequencies in a band of interest, is a labor intensive and error prone process. This research addresses the challenges facing development of a document processing capability that extracts quantities and units from S and T data, and how Natural Language Processing algorithms can be used to overcome these challenges.

  16. 10 CFR 455.123 - Grantee records and reports for State grants for administrative expenses, technical assistance...

    Science.gov (United States)

    2010-01-01

    ... administrative expenses, technical assistance, program assistance, and marketing. 455.123 Section 455.123 Energy....123 Grantee records and reports for State grants for administrative expenses, technical assistance... grant for technical assistance programs, program assistance, or marketing shall keep all the records...

  17. Non-technical skills in the intensive care unit

    NARCIS (Netherlands)

    Reader, T; Flin, R; Lauche, K; Cuthbertson, B.H.

    2006-01-01

    In high-risk industries such as aviation, the skills not related directly to technical expertise, but crucial for maintaining safety (e.g. teamwork), have been categorized as non-technical skills. Recently, research in anaesthesia has identified and developed a taxonomy of the non-technical skills r

  18. Non-technical skills in the intensive care unit

    NARCIS (Netherlands)

    Reader, T; Flin, R; Lauche, K; Cuthbertson, B.H.

    2006-01-01

    In high-risk industries such as aviation, the skills not related directly to technical expertise, but crucial for maintaining safety (e.g. teamwork), have been categorized as non-technical skills. Recently, research in anaesthesia has identified and developed a taxonomy of the non-technical skills r

  19. Records and history of the United States Geological Survey

    Science.gov (United States)

    Nelson, Clifford M.

    2000-01-01

    This publication contains two presentations in Portable Document Format (PDF). The first is Renee M. Jaussaud's inventory of the documents accessioned by the end of 1997 into Record Group 57 (Geological Survey) at the National Archives and Records Administration's (NARA) Archives II facility in College Park, Md., but not the materials in NARA's regional archives. The second is Mary C. Rabbitt's 'The United States Geological Survey 1879-1989,' which appeared in 1989 as USGS Circular 1050. Additionally, USGS Circular 1050 is also presented in Hyper Text Markup Language (HTML) format.

  20. The United States National Climate Assessment - Alaska Technical Regional Report

    Science.gov (United States)

    Markon, Carl J.; Trainor, Sarah F.; Chapin, F. Stuart; Markon, Carl J.; Trainor, Sarah F.; Chapin, F. Stuart

    2012-01-01

    The Alaskan landscape is changing, both in terms of effects of human activities as a consequence of increased population, social and economic development and their effects on the local and broad landscape; and those effects that accompany naturally occurring hazards such as volcanic eruptions, earthquakes, and tsunamis. Some of the most prevalent changes, however, are those resulting from a changing climate, with both near term and potential upcoming effects expected to continue into the future. Alaska's average annual statewide temperatures have increased by nearly 4°F from 1949 to 2005, with significant spatial variability due to the large latitudinal and longitudinal expanse of the State. Increases in mean annual temperature have been greatest in the interior region, and smallest in the State's southwest coastal regions. In general, however, trends point toward increases in both minimum temperatures, and in fewer extreme cold days. Trends in precipitation are somewhat similar to those in temperature, but with more variability. On the whole, Alaska saw a 10-percent increase in precipitation from 1949 to 2005, with the greatest increases recorded in winter. The National Climate Assessment has designated two well-established scenarios developed by the Intergovernmental Panel on Climate Change (Nakicenovic and others, 2001) as a minimum set that technical and author teams considered as context in preparing portions of this assessment. These two scenarios are referred to as the Special Report on Emissions Scenarios A2 and B1 scenarios, which assume either a continuation of recent trends in fossil fuel use (A2) or a vigorous global effort to reduce fossil fuel use (B1). Temperature increases from 4 to 22°F are predicted (to 2070-2099) depending on which emissions scenario (A2 or B1) is used with the least warming in southeast Alaska and the greatest in the northwest. Concomitant with temperature changes, by the end of the 21st century the growing season is expected

  1. 21 CFR 20.52 - Availability of records at National Technical Information Service.

    Science.gov (United States)

    2010-04-01

    ... Information Service. 20.52 Section 20.52 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PUBLIC INFORMATION Procedures and Fees § 20.52 Availability of records at National Technical Information Service. The Food and Drug Administration is furnishing a number of...

  2. 10 CFR 35.647 - Additional technical requirements for mobile remote afterloader units.

    Science.gov (United States)

    2010-01-01

    ... on the remote afterloader unit, on the control console, and in the facility; (3) Viewing and intercom... 10 Energy 1 2010-01-01 2010-01-01 false Additional technical requirements for mobile remote... MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic...

  3. United States: Ukraine Technical Exchange II trip report

    Energy Technology Data Exchange (ETDEWEB)

    Moak, D.J.; Wendling, M.A.

    1995-02-01

    May 15--21, 1994, the first technical conference was held at Hanford between Ukraine-Chornobyl, Westinghouse Hanford, and SAIC, to exchange technical information and experience gained in cleanup and stabilization of radioactive contamination at Hanford and Chornobyl. Protocol was signed for a second exchange and technology demonstration program in Kiev and near Chornobyl power plants. Technical Exchange No. 2 was held from August 28--September 9, 1994, with 3 focus areas: field demonstration of DOE-Hanford technologies and application to cleanup of contaminated lands resulting from 1986 Chornobyl accident; application of other US DOE-technologies; and observation/evaluation of Ukraine-developed technologies for potential application in USA. Three radiological mapping systems were demonstrated near Chornobyl: man-carried Ultrasonic Ranging and Data System, a mobile radiological data system, and NOMAD field gamma spectroscopy system. The Ukraine-Chornobyl team hosted technical presentations, discussions and field trips for 4.5 days, providing insight on the Chornobyl problem and allowing the US team to present overviews on DOE technologies that may be applicable to the Chornobyl situation. It is concluded that Ukrainian scientists have tremendous talent and expended considerable energy in attempting to tackle such a problem, but economic and cultural conditions with Ukraine have prevented them from acquiring the resources to implement basic aspects of characterization and remediation activities. Most of their publications are in Russian only. Their translation, plus resources to carry out proposals for bench scale and field demonstration projects, could benefit the DOE complex and other nuclear programs. The considerable cultural and economic change occurring in Ukraine, is providing opportunities for private industries to assist in the changes and for DOE, others to apply cleanup technologies, and it is essential that close institutional relations be established.

  4. The United States National Climate Assessment - Alaska Technical Regional Report

    Science.gov (United States)

    Markon, Carl J.; Trainor, Sarah F.; Chapin, F. Stuart; Markon, Carl J.; Trainor, Sarah F.; Chapin, F. Stuart

    2012-01-01

    The Alaskan landscape is changing, both in terms of effects of human activities as a consequence of increased population, social and economic development and their effects on the local and broad landscape; and those effects that accompany naturally occurring hazards such as volcanic eruptions, earthquakes, and tsunamis. Some of the most prevalent changes, however, are those resulting from a changing climate, with both near term and potential upcoming effects expected to continue into the future. Alaska's average annual statewide temperatures have increased by nearly 4°F from 1949 to 2005, with significant spatial variability due to the large latitudinal and longitudinal expanse of the State. Increases in mean annual temperature have been greatest in the interior region, and smallest in the State's southwest coastal regions. In general, however, trends point toward increases in both minimum temperatures, and in fewer extreme cold days. Trends in precipitation are somewhat similar to those in temperature, but with more variability. On the whole, Alaska saw a 10-percent increase in precipitation from 1949 to 2005, with the greatest increases recorded in winter. The National Climate Assessment has designated two well-established scenarios developed by the Intergovernmental Panel on Climate Change (Nakicenovic and others, 2001) as a minimum set that technical and author teams considered as context in preparing portions of this assessment. These two scenarios are referred to as the Special Report on Emissions Scenarios A2 and B1 scenarios, which assume either a continuation of recent trends in fossil fuel use (A2) or a vigorous global effort to reduce fossil fuel use (B1). Temperature increases from 4 to 22°F are predicted (to 2070-2099) depending on which emissions scenario (A2 or B1) is used with the least warming in southeast Alaska and the greatest in the northwest. Concomitant with temperature changes, by the end of the 21st century the growing season is expected

  5. Recording conventional and amplitude-integrated EEG in neonatal intensive care unit.

    Science.gov (United States)

    Neubauer, D; Osredkar, D; Paro-Panjan, D; Skofljanec, A; Derganc, M

    2011-09-01

    Neonatal electroencephalography (EEG) presents a challenge due to its difficult interpretation that differs significantly from interpretation in older children and adolescents. Also, from the technological point of view, it is more difficult to perform and is not a standard procedure in all neonatal intensive care units (NICUs). During recent years, long-term cerebral function monitoring by the means of amplitude-integrated EEG (aEEG) has become popular in NICUs because it is easy to apply, allows real-time interpretation by the neonatologist treating the newborn, and has predictive value for outcome. On the other side, to record conventional EEG (cEEG), which is still considered the gold standard of neonatal EEG, the EEG technician should not only be well trained in performing neonatal EEG but also has to adapt to suboptimal working conditions. These issues need to be understood when approaching the neonatal cEEG in NICU and the main structure of the article is dedicated to this technique. The authors discuss the benefits of the digitalization and its positive effects on the improvement of NICU recording. The technical aspects as well as the standards for cEEG recording are described, and a section is dedicated to possible artifacts. Thereafter, alternative and concomitant use of aEEG and its benefits are briefly discussed. At the end there is a section that presents a review of our own cEEG and aEEG recordings that were chosen as the most frequently encountered patterns according to Consensus statement on the use of EEG in the intensive care unit.

  6. Technical solutions for simultaneous MEG and SEEG recordings: towards routine clinical use.

    Science.gov (United States)

    Badier, J M; Dubarry, A S; Gavaret, M; Chen, S; Trébuchon, A S; Marquis, P; Régis, J; Bartolomei, F; Bénar, C G; Carron, R

    2017-09-21

    The simultaneous recording of intracerebral EEG (stereotaxic EEG, SEEG) and magnetoencephalography (MEG) is a promising strategy that provides both local and global views on brain pathological activity. Yet, acquiring simultaneous signals poses difficult technical issues that hamper their use in clinical routine. Our objective was thus to develop a set of solutions for recording a high number of SEEG channels while preserving signal quality. We recorded data in a patient with drug resistant epilepsy during presurgical evaluation. We used dedicated insertion screws and optically insulated amplifiers. We recorded 137 SEEG contacts on 10 depth electrodes (5-15 contacts each) and 248 MEG channels (magnetometers). Signal quality was assessed by comparing the distribution of RMS values in different frequency bands to a reference set of MEG acquisitions. The quality of signals was excellent for both MEG and SEEG; for MEG, it was comparable to that of MEG signals without concurrent SEEG. Discharges involving several structures on SEEG were visible on MEG, whereas discharges limited in space were not seen at the surface. SEEG can now be recorded simultaneously with whole-head MEG in routine. This opens new avenues, both methodologically for understanding signals and improving signal processing methods, and clinically for future combined analyses.

  7. Literature Survey on Technical Issues and Insights of Multi-Unit PSA

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Sejin; Park, Soyoung; Heo, Gyunyoung [Kyung Hee Univ., Yongin (Korea, Republic of)

    2016-10-15

    The need consider the risk impact in case of multi-unit in a single site increased after the accident at Fukushima Daiichi in March 2011. This means that we have to consider the single-unit initiators impacting the other units and the simultaneous accidents of the multi-unit on the same site. Particularly, this kind of technical concern is serious in case of the Republic of Korea where multi-units had to be located in high-density population area due to geographical features. The Nuclear Safety and Security Commission (NSSC) in the Republic of Korea has been trying to identify the state of the art of international and domestic regulations and techniques on multi-unit risk assessment and planning the road map for the safety researches. However, we have to say that finding a common accepted methodology along with safety criteria for multi-unit PSA was not an easy task up to now. This paper summarizes and analyzes related international and domestic journals' papers, conferences' papers and reports about the multi-unit PSA classifying categories with themes to understand the technical tendency of multi-unit PSA. In addition, some insights that were obtained from this classification have been arranged too. This paper investigated the technical trend of the multi-unit PSA as collecting of the international and domestic journals' papers, conferences papers and reports, and analyzing them. Upon the literature survey, a few statistics, technical issues, and insights were summarized. Both of the fundamental and practical researches need to find a globally accepted methodology to calculate and determine quantitative objectives for a multi-unit PSA. We want to expect that this paper can be shared to understand the current status of multi-unit PSA.

  8. A systematic literature review on security and privacy of electronic health record systems: technical perspectives.

    Science.gov (United States)

    Rezaeibagha, Fatemeh; Win, Khin Than; Susilo, Willy

    2015-01-01

    Even though many safeguards and policies for electronic health record (EHR) security have been implemented, barriers to the privacy and security protection of EHR systems persist. This article presents the results of a systematic literature review regarding frequently adopted security and privacy technical features of EHR systems. Our inclusion criteria were full articles that dealt with the security and privacy of technical implementations of EHR systems published in English in peer-reviewed journals and conference proceedings between 1998 and 2013; 55 selected studies were reviewed in detail. We analysed the review results using two International Organization for Standardization (ISO) standards (29100 and 27002) in order to consolidate the study findings. Using this process, we identified 13 features that are essential to security and privacy in EHRs. These included system and application access control, compliance with security requirements, interoperability, integration and sharing, consent and choice mechanism, policies and regulation, applicability and scalability and cryptography techniques. This review highlights the importance of technical features, including mandated access control policies and consent mechanisms, to provide patients' consent, scalability through proper architecture and frameworks, and interoperability of health information systems, to EHR security and privacy requirements.

  9. Technical evaluation of RETS-required reports for Fort Calhoun Station Unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Magleby, E.H.; Young, T.E.

    1985-06-24

    A review of the reports required by federal regulations and the plant-specific Radiological Effluent Technical Specifications (RETS) for operations conducted during 1983 was performed. The periodic reports reviewed for Fort Calhoun Station Unit 1 were two Semiannual Reports for Technical Specification 5.9.4. The principal review guidelines were the plant's specific RETS, NUREG-0133, ''Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants'', and NRC Guidance on the Review of the Process Control Programs. The Licensee's submitted reports were found to be reasonably complete and consistent with the review guidelines. 4 refs.

  10. Technical and architectural issues in deploying electronic health records (EHRs) over the WWW.

    Science.gov (United States)

    Armstrong, Brian; Kushniruk, Andre; Joe, Ron; Borycki, Elizabeth

    2009-01-01

    In this paper technical and architectural issues are described in deploying electronic health records (EHRs) over the WWW. The project described involved deployment of EHRs that have been designed to serve in the education of health professionals and health/biomedical informaticians. In order to allow for ubiquitous access to a range of EHRs remotely an architecture was designed with three layers: (a) the "Internet" or remote user access layer (2) the "Perimeter Network", or middle firewall security and authentication layer (3) the "HINF EHR Network", consisting of the internal servers hosting EHR applications and databases. The approaches allow for a large number of remote users running a range of operating systems to access the educational EHRs from any location remotely. Virtual machine (VM) technology is employed to allow multiple versions and platforms of operating systems to be installed side-by-side on a single server. Security, technical and budgetary considerations are described as well as past and current applications of the architecture for a number of projects for the education of health professionals in the area of electronic health records.

  11. Services and technical units for radiological protection; Servicios y unidades tecnicas de proteccion radiologica

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    Spanish law establishes the standard concerning ionizing radiation in accordance to European Union directives. the Spanish NSC (CSN) is the regulatory body in matters of radiological safety which issues a perceptive report on work conditions in everything related to radiological protection of nuclear and radioactive installations. It also inspects and approves their action protocols and makes demands that certain entities employ additional support with respect to radiological protection which they can receive through calls for radiological protection services and technical units. This article takes a look at what these services and technical units are and how they act. (Author)

  12. Genome privacy: challenges, technical approaches to mitigate risk, and ethical considerations in the United States.

    Science.gov (United States)

    Wang, Shuang; Jiang, Xiaoqian; Singh, Siddharth; Marmor, Rebecca; Bonomi, Luca; Fox, Dov; Dow, Michelle; Ohno-Machado, Lucila

    2017-01-01

    Accessing and integrating human genomic data with phenotypes are important for biomedical research. Making genomic data accessible for research purposes, however, must be handled carefully to avoid leakage of sensitive individual information to unauthorized parties and improper use of data. In this article, we focus on data sharing within the scope of data accessibility for research. Current common practices to gain biomedical data access are strictly rule based, without a clear and quantitative measurement of the risk of privacy breaches. In addition, several types of studies require privacy-preserving linkage of genotype and phenotype information across different locations (e.g., genotypes stored in a sequencing facility and phenotypes stored in an electronic health record) to accelerate discoveries. The computer science community has developed a spectrum of techniques for data privacy and confidentiality protection, many of which have yet to be tested on real-world problems. In this article, we discuss clinical, technical, and ethical aspects of genome data privacy and confidentiality in the United States, as well as potential solutions for privacy-preserving genotype-phenotype linkage in biomedical research. © 2016 New York Academy of Sciences.

  13. 15 CFR 40.3 - Cooperation with bilateral technical assistance programs of the United States.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Cooperation with bilateral technical assistance programs of the United States. 40.3 Section 40.3 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade BUREAU OF THE CENSUS, DEPARTMENT OF COMMERCE TRAINING OF FOREIGN...

  14. An Investigation Into the Feasibility of Merging Three Technical Processing Operations Into One Central Unit.

    Science.gov (United States)

    Burns, Robert W., Jr.

    Three contiguous schools in the upper midwest--a teacher's training college and a private four-year college in one state, and a land-grant university in another--were studied to see if their libraries could merge one of their major divisions--technical services--into a single administrative unit. Potential benefits from such a merger were felt to…

  15. 77 FR 58470 - Irradiation Treatment; Location of Facilities in the Southern United States; Technical Amendment

    Science.gov (United States)

    2012-09-21

    ... Animal and Plant Health Inspection Service 7 CFR Part 319 RIN 0579-AD35 Irradiation Treatment; Location of Facilities in the Southern United States; Technical Amendment AGENCY: Animal and Plant Health... approving treatment facilities for fruits, vegetables, and other articles to prevent the introduction or...

  16. [Determining and recording maxillomandibular relationships for the fabrication of single-unit and multi-unit fixed dental prostheses

    NARCIS (Netherlands)

    Wiersema, E.J.; Kreulen, C.M.; Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2013-01-01

    In a correctly functioning occlusal system, the design of the occlusal parts of single-unit and multi-unit fixed dental prostheses is generally determined by the maximum intercuspation. Determining and recording the maxillomandibular relationships is only required in case the adjacent teeth do not

  17. [Determining and recording maxillomandibular relationships for the fabrication of single-unit and multi-unit fixed dental prostheses

    NARCIS (Netherlands)

    Wiersema, E.J.; Kreulen, C.M.; Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2013-01-01

    In a correctly functioning occlusal system, the design of the occlusal parts of single-unit and multi-unit fixed dental prostheses is generally determined by the maximum intercuspation. Determining and recording the maxillomandibular relationships is only required in case the adjacent teeth do not o

  18. The effect of ground electrode on the sensitivity, symmetricity and technical feasibility of scalp EEG recordings.

    Science.gov (United States)

    Paukkunen, Antti Kimmo Olavi; Sepponen, Raimo

    2008-09-01

    Although the choice of the measurement reference strongly affects the measurement sensitivity, validity and comparability, selection is often based on tradition, convenience and comparability to earlier results [Dien in Behav Res Methods Ins C 30(1):34-43, 1998; Femi and Sundor in Int J Psychosom 36(1-4):23-33; 1989]. Artificial means can be applied to compensate for the referential issues, but they cannot restore any lost data. The validity of the recorded data is ultimately defined by the hardware setup. In this simulation study, common average ground reference (AR) is characterized and compared to two alternative common ground reference schemes in respect to their influence on the sensitivity distribution and technical feasibility of scalp EEG recording. It was found that, despite the polar average reference effect [Junghöfer et al. in Clin Neurophysiol 110(6):1149-1155; 1999], AR merits a significantly higher symmetricity and should be promoted generally not only in high-electrode-density studies, but also in low-channel-count studies if the stringent design requirements can be met. In low-electrode-density studies, balancing the setup may prove challenging, but successful implementation can provide nearly undistorted data. Isolation of the system is a critical parameter, but technological advances enable the requirements to be fulfilled. A physical ground should be applied if high isolation is not applicable or if it is defined by the application. The results will apply for the applied homogenous concentric 3-sphere model, but should be further studied in a realistic context if more detailed and case-sensitive information is required; the underlying phenomena are generally applicable.

  19. Basic Concepts and Definitions for Privacy and Confidentiality in Student Education Records. SLDS Technical Brief 1. NCES 2011-601

    Science.gov (United States)

    National Center for Education Statistics, 2010

    2010-01-01

    The National Center for Education Statistics (NCES) is launching a new series of Technical Briefs on various aspects of the protection of personally identifiable information in students' education records. While driven by recent events, the principles and practices that are outlined in this series can be applied more generally to personally…

  20. Massively parallel recording of unit and local field potentials with silicon-based electrodes.

    Science.gov (United States)

    Csicsvari, Jozsef; Henze, Darrell A; Jamieson, Brian; Harris, Kenneth D; Sirota, Anton; Barthó, Péter; Wise, Kensall D; Buzsáki, György

    2003-08-01

    Parallel recording of neuronal activity in the behaving animal is a prerequisite for our understanding of neuronal representation and storage of information. Here we describe the development of micro-machined silicon microelectrode arrays for unit and local field recordings. The two-dimensional probes with 96 or 64 recording sites provided high-density recording of unit and field activity with minimal tissue displacement or damage. The on-chip active circuit eliminated movement and other artifacts and greatly reduced the weight of the headgear. The precise geometry of the recording tips allowed for the estimation of the spatial location of the recorded neurons and for high-resolution estimation of extracellular current source density. Action potentials could be simultaneously recorded from the soma and dendrites of the same neurons. Silicon technology is a promising approach for high-density, high-resolution sampling of neuronal activity in both basic research and prosthetic devices.

  1. Interim Status Closure Plan Open Burning Treatment Unit Technical Area 16-399 Burn Tray

    Energy Technology Data Exchange (ETDEWEB)

    Vigil-Holterman, Luciana R. [Los Alamos National Laboratory

    2012-05-07

    This closure plan describes the activities necessary to close one of the interim status hazardous waste open burning treatment units at Technical Area (TA) 16 at the Los Alamos National Laboratory (LANL or the Facility), hereinafter referred to as the 'TA-16-399 Burn Tray' or 'the unit'. The information provided in this closure plan addresses the closure requirements specified in the Code of Federal Regulations (CFR), Title 40, Part 265, Subparts G and P for the thermal treatment units operated at the Facility under the Resource Conservation and Recovery Act (RCRA) and the New Mexico Hazardous Waste Act. Closure of the open burning treatment unit will be completed in accordance with Section 4.1 of this closure plan.

  2. Can technical, functional and structural characteristics of dental units predict Legionella pneumophila and Pseudomonas aeruginosa contamination?

    Science.gov (United States)

    Aprea, Luigi; Cannova, Lucia; Firenze, Alberto; Bivona, Maria S; Amodio, Emanuele; Romano, Nino

    2010-12-01

    Legionella pneumophila and Pseudomonas aeruginosa are common colonizers of water environments, particularly dental unit waterlines. The aim of this study was to assess whether the technical, functional and structural characteristics of dental units can influence the presence and the levels of opportunistic pathogens. Overall, 42 water samples were collected from dental units in a teaching hospital in Palermo, Italy, including 21 samples from the 21 taps supplied by the municipal water distribution system and 21 samples from oral rinsing cups at 21 dental units. L. pneumophila was present in 16 out of 21 water samples (76.2%) from dental units, and the median concentration was higher in samples from oral rinsing cups than in those from taps (P < 0.001). P. aeruginosa was equally distributed in water samples collected from oral rinsing cups and from taps. Some characteristics of dental units (age, number of chairs per room, number of patients per day and water temperature) were slightly associated with the presence of P. aeruginosa, but not with contamination by L. pneumophila. Our experience suggests that L. pneumophila is frequently detected in dental units, as reported in previous studies, whereas P. aeruginosa is not a frequent contaminant. As a consequence, microbiological control of water quality should be routinely performed, and should include the detection of opportunistic pathogens when bacterial contamination is expected.

  3. Returns and determinants of technical efficiency in small-scale Malabari goat production units in Kerala, India.

    Science.gov (United States)

    Alex, Rani; Kunniyoor Cheemani, Raghavan; Thomas, Naicy

    2013-11-01

    A stochastic frontier production function was employed to measure technical efficiency and its determinants in smallholder Malabari goat production units in Kerala, India. Data were obtained from 100 goat farmers in northern Kerala, selected using multistage random sampling. The parameters of the stochastic frontier production function were estimated using the maximum likelihood method. Cost and return analysis showed that the major expenditure was feed and fodder, and veterinary expenses were secondary. The chief returns were the sale of live animals, milk and manure. Individual farm technical efficiency ranged from 0.34 to 0.97 with a mean of 0.88. The study found herd size (number of animal units) and centre (locality of farm) significantly affected technical efficiency, but sex of farmer, education, land size and family size did not. Technical efficiency decreased as herd size increased; half the units with five or more adult animals had technical efficiency below 60 %.

  4. 34 CFR 99.8 - What provisions apply to records of a law enforcement unit?

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false What provisions apply to records of a law enforcement... RIGHTS AND PRIVACY General § 99.8 What provisions apply to records of a law enforcement unit? (a)(1) Law..., State, or Federal law, or refer to appropriate authorities a matter for enforcement of any local, State...

  5. 36 CFR 1235.12 - When must agencies transfer records to the National Archives of the United States?

    Science.gov (United States)

    2010-07-01

    ... records to the National Archives of the United States? 1235.12 Section 1235.12 Parks, Forests, and Public... NATIONAL ARCHIVES OF THE UNITED STATES General Transfer Requirements § 1235.12 When must agencies transfer records to the National Archives of the United States? Permanent records must be transferred to...

  6. 36 CFR 1235.18 - How do agencies transfer records to the National Archives of the United States?

    Science.gov (United States)

    2010-07-01

    ... records to the National Archives of the United States? 1235.18 Section 1235.18 Parks, Forests, and Public... NATIONAL ARCHIVES OF THE UNITED STATES General Transfer Requirements § 1235.18 How do agencies transfer records to the National Archives of the United States? Agencies transfer records by submitting a signed...

  7. United States Air Force Technical Order Acquisition. What Can Be Done to Improve the Effectiveness of the Technical Order Manager?

    Science.gov (United States)

    1985-09-01

    leveled CTOC framework, the following recommendations were made: 1. The establishment of a career field for senior TO acqusition personnel based on...capacity or another. The students were familiar with the terms and language normally associated with technical orders and were enrolled in Technical... acqusition is easy to learn; a background in the technical specialty is more important (ie. radio repair) - need more emphasis on logistics in general; TOs

  8. Evaluation of autonomous recording units for detecting 3 species of secretive marsh birds

    Science.gov (United States)

    Sidie-Slettehahl, Anna M.; Jensen, Kent C.; Johnson, Rex R.; Arnold, Todd W.; Austin, Jane; Stafford, Joshua D.

    2015-01-01

    Population status and habitat use of yellow rails (Coturnicops noveboracensis), Nelson's sparrows (Ammodramus nelsoni), and Le Conte's sparrows (A. leconteii) are poorly known, so standardized surveys of these species are needed to inform conservation planning and management. A protocol for monitoring secretive marsh birds exists; however, these species regularly call at night and may be missed during early morning surveys. We tested the effectiveness of autonomous recording units (hereafter, recording units) to survey these species by analyzing recorded vocalizations using bioacoustics software. We deployed 22 recording units at 54 sites in northern Minnesota and eastern North Dakota, USA, and conducted traditional broadcast surveys during May–June, 2010 and 2011. We compared detection probabilities between recording units and standard monitoring protocols using robust-design occupancy models. On average, recording units detected 0.59 (SE = 0.11) fewer Le Conte's sparrows, 0.76 (SE = 0.15) fewer Nelson's sparrows, and 1.01 (SE = 0.14) fewer yellow rails per survey than were detected using the standard protocol. Detection probabilities using the standard protocol averaged 0.95 (yellow rail; 95% CI = 0.86–0.98), 0.93 (Le Conte's sparrow; 95% CI = 0.78–0.98), and 0.89 (Nelson's sparrow; 95% CI = 0.56–0.98), but averaged 0.71 (yellow rail; 95% CI = 0.56–0.83), 0.61 (Le Conte's sparrow; 95% CI = 0.42–0.78), and 0.51 (Nelson's sparrow; 95% CI = 0.19–0.82) using recording units. Reduced detection by recording units was likely due to the ability of human listeners to identify birds calling at greater distances. Recording units may be effective for surveying nocturnal secretive marsh birds if investigators correct for differential detectability. Reduced detectability may be outweighed by the increased spatial and temporal coverage feasible with recording units.

  9. TECHNICAL NOTE: The development of a PZT-based microdrive for neural signal recording

    Science.gov (United States)

    Park, Sangkyu; Yoon, Euisung; Lee, Sukchan; Shin, Hee-sup; Park, Hyunjun; Kim, Byungkyu; Kim, Daesoo; Park, Jongoh; Park, Sukho

    2008-04-01

    A hand-controlled microdrive has been used to obtain neural signals from rodents such as rats and mice. However, it places severe physical stress on the rodents during its manipulation, and this stress leads to alertness in the mice and low efficiency in obtaining neural signals from the mice. To overcome this issue, we developed a novel microdrive, which allows one to adjust the electrodes by a piezoelectric device (PZT) with high precision. Its mass is light enough to install on the mouse's head. The proposed microdrive has three H-type PZT actuators and their guiding structure. The operation principle of the microdrive is based on the well known inchworm mechanism. When the three PZT actuators are synchronized, linear motion of the electrode is produced along the guiding structure. The electrodes used for the recording of the neural signals from neuron cells were fixed at one of the PZT actuators. Our proposed microdrive has an accuracy of about 400 nm and a long stroke of about 5 mm. In response to formalin-induced pain, single unit activities are robustly measured at the thalamus with electrodes whose vertical depth is adjusted by the microdrive under urethane anesthesia. In addition, the microdrive was efficient in detecting neural signals from mice that were moving freely. Thus, the present study suggests that the PZT-based microdrive could be an alternative for the efficient detection of neural signals from mice during behavioral states without any stress to the mice.

  10. Status of technical radiation protection units; Situacion de las Unidades Tecnicas de Proteccion Radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Arguelles Sanchez, R.; Rodriguez Marti, M.; Sierra Perler, I. C.; Villarroel Gonzalez-Elipe, R.

    2009-07-01

    The aim of this report is to analyse the current situation of Radiological Protection technical Units until December 2008 and to carry out an evaluation on the quality the services provided to clients in terms of nuclear safety and radiation protection at nuclear facilities and radioactive and medical radiodiagnostics facilities in accordance with the function assigned to them by the CSN. these are set forth in the Rules of Health Protection against ionising radiation and the RD 1976/1999 on quality criteria applied to radiodiagnostics. (Author)

  11. United States Air Force Summer Faculty Research Program. 1985 Technical Report. Volume 3.

    Science.gov (United States)

    1985-12-01

    Air Force materials with polution potential include jet fuel, deicer, different pesticides and Aqueous Fire Fighting Foam (AFFF). Spills and leakage...L AD-Ai66 178 UNITED STATES AIR FORCE SUMMER FACULTY RESEARCH PROGRAM 1/11 1985 TECHNICAL RE..(U) UNIVERSAL ENERGY SYSTEMS INC DAYTON OH R C DARRAH...EIIIIEEEIIIEEE 36 Ml ROCOPY RESOLUTION TEST CHART NtATIONdAL "URI4 OF SVAOAS - 963 -A j AIR FORCE OFFICE OF SCIENTIFIC RESEAfjCH-- ;’’UNITEP.STATES A11R.-FORG

  12. An exponential smoothing method application to restoring lost data on electric power technical record-keeping in industrial enterprises

    Directory of Open Access Journals (Sweden)

    Ya.S. Bederak

    2014-09-01

    Full Text Available The paper studies in detail a problem of restoring single data of electric power technical record-keeping systems by means of exponential smoothing. A hypothesis of efficient finding the optimal value of smoothing constant α in the range of 0 < α < 2 is tested. Variation ranges for the mean absolute percentage error of the forecast are specified versus values of the time series variation coefficient for specific electricity consumption processes with different data spread.

  13. [Technical and functional standards and implementation of a clinical information system in intensive care units].

    Science.gov (United States)

    Gómez Tello, V; Alvarez Rodríguez, J; Núñez Reiz, A; González Sánchez, J A; Hernández Abadía de Barbará, A; Martínez Fresneda, M; Morrondo Valdeolmillos, P; Nicolás Arfelis, J M; Pujol Varela, I; Calvete Chicharro, M

    2011-11-01

    Clinical Information Systems (CIS) are becoming a useful tool for managing patients and data in the ICU. However, the existing CIS differ in their capabilities and technical requirements. It is therefore essential for intensivists, as the end clients of these applications, to define the suitable minimum specifications required in order to be operative and helpful. The Spanish Society of Intensive Care Medicine and Coronary Units, through its Organization and Management Workgroup, has designated a group of clinical and software experts to draft a document with the recommendable technical and operating requirements of these systems. The group was formed by ten people supported by managers or engineers from the five principal industries producing CIS in Spain. The project involved the following phases: a) Completion of a check list. This step was considered necessary in order to establish the precise current situation of CIS applications. b) Discussion of the results by the group of experts in a meeting and in online format. The requirements were grouped into four sections: technical, functional, safety and data management. All requirements were classified as basic and optional in order to allow the end user to choose among different options according to the existing budget, though ensuring a minimal set of useful characteristics. A chronogram for the installation process was also proposed. Copyright © 2011 Elsevier España, S.L. y SEMICYUC. All rights reserved.

  14. Rooftop Solar Photovoltaic Technical Potential in the United States. A Detailed Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States); Melius, Jennifer [National Renewable Energy Lab. (NREL), Golden, CO (United States); Phillips, Caleb [National Renewable Energy Lab. (NREL), Golden, CO (United States); Elmore, Ryan [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-01-01

    How much energy could be generated if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models--one for small buildings and one for medium and large buildings--and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

  15. Assessment of across-muscle coherence using multi-unit vs. single-unit recordings.

    Science.gov (United States)

    Johnston, Jamie A; Formicone, Gabriele; Hamm, Thomas M; Santello, Marco

    2010-12-01

    Coherence between electromyographic (EMG) signals has been used to identify correlated neural inputs to motor units (MUs) innervating different muscles. Simulations using a motor-unit model (Fuglevand et al. 1992) were performed to determine the ability of coherence between two multi-unit EMGs (mEMG) to detect correlated MU activity and the range of correlation strengths in which mEMG coherence can be usefully employed. Coherence between motor-unit and mEMG activities in two muscles was determined as we varied the strength of a 30-Hz periodic common input, the number of correlated MU pairs and variability of MU discharge relative to the common input. Pooled and mEMG coherence amplitudes positively and negatively accelerated, respectively, toward the strongest and most widespread correlating inputs. Furthermore, the relation between pooled and mEMG coherence was also nonlinear and was essentially the same whether correlation strength varied by changing common input strength or its distribution. However, the most important finding is that while the mEMG coherence saturates at the strongest common input strengths, this occurs at common input strengths greater than found in most physiological studies. Thus, we conclude that mEMG coherence would be a useful measure in many experimental conditions and our simulation results suggest further guidelines for using and interpreting coherence between mEMG signals.

  16. Head of the bed elevation angle recorder for intensive care unit

    Science.gov (United States)

    Krefft, Maciej; Zamaro-Michalska, Aleksandra; Zabołotny, Wojciech M.; Zaworski, Wojciech; Grzanka, Antoni; Łazowski, Tomasz; Tavola, Mario; Siewiera, Jacek; Mikaszewska-Sokolewicz, Małgorzata

    2013-10-01

    This paper presents a recording system optimized for long term measurement of bed headrest elevation angle in the Intensive Care Unit. The continuous monitoring of this parameter allows to find the correlation between the patient's position in bed and the risk of the Ventilator Associated Pneumonia (VAP), a very serious problem in therapy of critically ill patients. Recorder might be be an important tool to evaluate the "care bundles" - sets of preventive procedures recommended for treatment of patients in the ICU.

  17. Personal health records in the South African healthcare landscape: a socio-technical analysis

    CSIR Research Space (South Africa)

    Mxoli, A

    2014-11-01

    Full Text Available and control non-communicable lifestyle diseases. Despite numerous benefits adoption rates are low, and little is known regarding the factors that affect adoption in the South African context. This exploratory paper highlights socio-technical factors that can...

  18. 36 CFR 1235.30 - How may records in the National Archives of the United States be used?

    Science.gov (United States)

    2010-07-01

    ... National Archives of the United States be used? 1235.30 Section 1235.30 Parks, Forests, and Public Property... ARCHIVES OF THE UNITED STATES Administration of Transferred Records § 1235.30 How may records in the National Archives of the United States be used? (a) NARA will enforce restrictions that are consistent...

  19. Technical cooperation on nuclear security between the United States and China : review of the past and opportunities for the future.

    Energy Technology Data Exchange (ETDEWEB)

    Pregenzer, Arian Leigh

    2011-12-01

    The United States and China are committed to cooperation to address the challenges of the next century. Technical cooperation, building on a long tradition of technical exchange between the two countries, can play an important role. This paper focuses on technical cooperation between the United States and China in the areas of nonproliferation, arms control and other nuclear security topics. It reviews cooperation during the 1990s on nonproliferation and arms control under the U.S.-China Arms Control Exchange, discusses examples of ongoing activities under the Peaceful Uses of Technology Agreement to enhance security of nuclear and radiological material, and suggests opportunities for expanding technical cooperation between the defense nuclear laboratories of both countries to address a broader range of nuclear security topics.

  20. Using State Student Unit Record Data to Increase Community College Student Success

    Science.gov (United States)

    Ewell, Peter; Jenkins, Davis

    2008-01-01

    This chapter examines lessons learned by states that are using student unit record (SUR) data to improve outcomes for community college students and recommends steps states can take to strengthen their use of SUR databases to benefit students and communities. (Contains 1 exhibit.)

  1. Orchard Business Management. Unit I. Establishing an Orchard Record Keeping System.

    Science.gov (United States)

    Mullinix, Shauna K.

    This guide is intended for use in providing in-depth formal classroom and on-site instruction in the principles of business and financial management as they apply to operating and managing orchards. Designed to be used with an accompanying Orchard Business Management Record Book, this unit (i.e., the first year) of the course deals with…

  2. 26 CFR 1.964-3 - Records to be provided by United States shareholders.

    Science.gov (United States)

    2010-04-01

    ... which § 1.952-3 does not apply, such amounts shall be determined under 26 CFR § 1.954-1(d)(3)(i) and (ii... shareholders. 1.964-3 Section 1.964-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY... provided by United States shareholders. (a) Shareholder's responsibility for providing records....

  3. Orchard Business Management. Unit I. Establishing an Orchard Record Keeping System.

    Science.gov (United States)

    Mullinix, Shauna K.

    This guide is intended for use in providing in-depth formal classroom and on-site instruction in the principles of business and financial management as they apply to operating and managing orchards. Designed to be used with an accompanying Orchard Business Management Record Book, this unit (i.e., the first year) of the course deals with…

  4. Rejecting renewables. The socio-technical impediments to renewable electricity in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Sovacool, Benjamin K. [Energy Governance Program, Centre on Asia and Globalisation, Lee Kuan Yew School of Public Policy, National University of Singapore (Singapore)

    2009-11-15

    If renewable power systems deliver such impressive benefits, why do they still provide only 3 percent of national electricity generation in the United States? As an answer, this article demonstrates that the impediments to renewable power are socio-technical, a term that encompasses the technological, social, political, regulatory, and cultural aspects of electricity supply and use. Extensive interviews of public utility commissioners, utility managers, system operators, manufacturers, researchers, business owners, and ordinary consumers reveal that it is these socio-technical barriers that often explain why wind, solar, biomass, geothermal, and hydroelectric power sources are not embraced. Utility operators reject renewable resources because they are trained to think only in terms of big, conventional power plants. Consumers practically ignore renewable power systems because they are not given accurate price signals about electricity consumption. Intentional market distortions (such as subsidies), and unintentional market distortions (such as split incentives) prevent consumers from becoming fully invested in their electricity choices. As a result, newer and cleaner technologies that may offer social and environmental benefits but are not consistent with the dominant paradigm of the electricity industry continue to face comparative rejection. (author)

  5. Rejecting renewables: The socio-technical impediments to renewable electricity in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Sovacool, Benjamin K., E-mail: bsovacool@nus.edu.s [Energy Governance Program, Centre on Asia and Globalisation, Lee Kuan Yew School of Public Policy, National University of Singapore (Singapore)

    2009-11-15

    If renewable power systems deliver such impressive benefits, why do they still provide only 3 percent of national electricity generation in the United States? As an answer, this article demonstrates that the impediments to renewable power are socio-technical, a term that encompasses the technological, social, political, regulatory, and cultural aspects of electricity supply and use. Extensive interviews of public utility commissioners, utility managers, system operators, manufacturers, researchers, business owners, and ordinary consumers reveal that it is these socio-technical barriers that often explain why wind, solar, biomass, geothermal, and hydroelectric power sources are not embraced. Utility operators reject renewable resources because they are trained to think only in terms of big, conventional power plants. Consumers practically ignore renewable power systems because they are not given accurate price signals about electricity consumption. Intentional market distortions (such as subsidies), and unintentional market distortions (such as split incentives) prevent consumers from becoming fully invested in their electricity choices. As a result, newer and cleaner technologies that may offer social and environmental benefits but are not consistent with the dominant paradigm of the electricity industry continue to face comparative rejection.

  6. Geothermal power plants of the United States: a technical survey of existing and planned installations

    Energy Technology Data Exchange (ETDEWEB)

    DiPippo, R.

    1978-04-01

    The development of geothermal energy as a source of electric power in the United States is reviewed. A thorough description is given of The Geysers geothermal power project in northern California. The recent efforts to exploit the hot-water resources of the Mexicali-Imperial Rift Valley are described. Details are given concerning the geology of the several sites now being used and for those at which power plants will soon be built. Attention is paid to the technical particulars of all existing plants, including wells, gathering systems, energy conversion devices, materials, environmental impacts, economics and operating characteristics. Specifically, plants which either exist or are planned for the following locations are covered: The Geysers, CA; East Mesa, CA; Heber, CA; Roosevelt Hot Springs, UT; Valles Caldera, NM; Salton Sea, CA; Westmorland, CA; Brawley, CA; Desert Peak, NV; and Raft River, ID. The growth of installed geothermal electric generating capacity is traced from the beginning in 1960 and is projected to 1984.

  7. Bio-inspired benchmark generator for extracellular multi-unit recordings

    Science.gov (United States)

    Mondragón-González, Sirenia Lizbeth; Burguière, Eric

    2017-01-01

    The analysis of multi-unit extracellular recordings of brain activity has led to the development of numerous tools, ranging from signal processing algorithms to electronic devices and applications. Currently, the evaluation and optimisation of these tools are hampered by the lack of ground-truth databases of neural signals. These databases must be parameterisable, easy to generate and bio-inspired, i.e. containing features encountered in real electrophysiological recording sessions. Towards that end, this article introduces an original computational approach to create fully annotated and parameterised benchmark datasets, generated from the summation of three components: neural signals from compartmental models and recorded extracellular spikes, non-stationary slow oscillations, and a variety of different types of artefacts. We present three application examples. (1) We reproduced in-vivo extracellular hippocampal multi-unit recordings from either tetrode or polytrode designs. (2) We simulated recordings in two different experimental conditions: anaesthetised and awake subjects. (3) Last, we also conducted a series of simulations to study the impact of different level of artefacts on extracellular recordings and their influence in the frequency domain. Beyond the results presented here, such a benchmark dataset generator has many applications such as calibration, evaluation and development of both hardware and software architectures. PMID:28233819

  8. cVEMP morphology changes with recording electrode position, but single motor unit activity remains constant.

    Science.gov (United States)

    Rosengren, Sally M; Colebatch, James G; Borire, Adeniyi; Straumann, Dominik; Weber, Konrad P

    2016-04-15

    Cervical vestibular evoked myogenic potentials (cVEMPs) recorded over the lower quarter of the sternocleidomastoid (SCM) muscle in normal subjects may have opposite polarity to those recorded over the midpoint. It has thus been suggested that vestibular projections to the lower part of SCM might be excitatory rather than inhibitory. We tested the hypothesis that the SCM muscle receives both inhibitory and excitatory vestibular inputs. We recorded cVEMPs in 10 normal subjects with surface electrodes placed at multiple sites along the anterior (sternal) component of the SCM muscle. We compared several reference sites: sternum, ipsilateral and contralateral earlobes, and contralateral wrist. In five subjects, single motor unit responses were recorded at the upper, middle, and lower parts of the SCM muscle using concentric needle electrodes. The surface cVEMP had the typical positive-negative polarity at the midpoint of the SCM muscle. In all subjects, as the recording electrode was moved toward each insertion point, p13 amplitude became smaller and p13 latency increased, then the polarity inverted to a negative-positive waveform (n1-p1). Changing the reference site did not affect reflex polarity. There was a significant short-latency change in activity in 61/63 single motor units, and in each case this was a decrease or gap in firing, indicating an inhibitory reflex. Single motor unit recordings showed that the reflex was inhibitory along the entire SCM muscle. The cVEMP surface waveform inversion near the mastoid and sternal insertion points likely reflects volume conduction of the potential occurring with increasing distance from the motor point.

  9. Determination of technical and economic parameters of an ionic transport membrane air separation unit working in a supercritical power plant

    Directory of Open Access Journals (Sweden)

    Kotowicz Janusz

    2016-09-01

    Full Text Available In this paper an air separation unit was analyzed. The unit consisted of: an ionic transport membrane contained in a four-end type module, an air compressor, an expander fed by gas that remains after oxygen separation and heat exchangers which heat the air and recirculated flue gas to the membrane operating temperature (850 °C. The air separation unit works in a power plant with electrical power equal to 600 MW. This power plant additionally consists of: an oxy-type pulverized-fuel boiler, a steam turbine unit and a carbon dioxide capture unit. Life steam parameters are 30 MPa/650 °C and reheated steam parameters are 6 MPa/670 °C. The listed units were analyzed. For constant electrical power of the power plant technical parameters of the air separation unit for two oxygen recovery rate (65% and 95% were determined. One of such parameters is ionic membrane surface area. In this paper the formulated equation is presented. The remaining technical parameters of the air separation unit are, among others: heat exchange surface area, power of the air compressor, power of the expander and auxiliary power. Using the listed quantities, the economic parameters, such as costs of air separation unit and of individual components were determined. These quantities allowed to determine investment costs of construction of the air separation unit. In addition, they were compared with investment costs for the entire oxy-type power plant.

  10. Human motor unit recordings: origins and insight into the integrated motor system.

    Science.gov (United States)

    Duchateau, Jacques; Enoka, Roger M

    2011-08-29

    Soon after Edward Liddell [1895-1981] and Charles Sherrington [1857-1952] introduced the concept of a motor unit in 1925 and the necessary technology was developed, the recording of single motor unit activity became feasible in humans. It was quickly discovered by Edgar Adrian [1889-1977] and Detlev Bronk [1897-1975] that the force exerted by muscle during voluntary contractions was the result of the concurrent recruitment of motor units and modulation of the rate at which they discharged action potentials. Subsequent studies found that the relation between discharge frequency and motor unit force was characterized by a sigmoidal function. Based on observations on experimental animals, Elwood Henneman [1915-1996] proposed a "size principle" in 1957 and most studies in humans focussed on validating this concept during various types of muscle contractions. By the end of the 20th C, the experimental evidence indicated that the recruitment order of human motor units was determined primarily by motoneuron size and that the occasional changes in recruitment order were not an intended strategy of the central nervous system. Fundamental knowledge on the function of Sherrington's "common final pathway" was expanded with observations on motor unit rotation, minimal and maximal discharge rates, discharge variability, and self-sustained firing. Despite the great amount of work on characterizing motor unit activity during the first century of inquiry, however, many basic questions remain unanswered and these limit the extent to which findings on humans and experimental animals can be integrated and generalized to all movements.

  11. Lubrication Specialist: Task List and Competency Record. Developed for Vocational-Technical Curriculum Articulation in Minnesota.

    Science.gov (United States)

    Minnesota State Dept. of Education, St. Paul. Div. of Vocational and Technical Education.

    Intended for the vocational instructor, the booklet presents a task list and competency record for the occupational program of lubrication specialist. The list was developed by a working committee of auto mechanics instructors and industry representatives throughout the state of Minnesota for use in program articulation between secondary and…

  12. Technical Limitations of Electronic Health Records in Community Health Centers: Implications on Ambulatory Care Quality

    Science.gov (United States)

    West, Christopher E.

    2010-01-01

    Research objectives: This dissertation examines the state of development of each of the eight core electronic health record (EHR) functionalities as described by the IOM and describes how the current state of these functionalities limit quality improvement efforts in ambulatory care settings. There is a great deal of literature describing both the…

  13. Technical standards for recording and interpretation of neonatal electroencephalogram in clinical practice

    NARCIS (Netherlands)

    P.J. Cherian (Joseph); R.M.C. Swarte (Renate); G.H. Visser (Gerhard Henk)

    2009-01-01

    textabstractNeonatal electroencephalogram (EEG), though often perceived as being difficult to record and interpret, is relatively easy to study due to the immature nature of the brain, which expresses only a few well-defined set of patterns. The EEG interpreter needs to be aware of the maturational

  14. A conservation ontology and knowledge base to support delivery of technical assistance to agricultural producers in the united states

    Science.gov (United States)

    Information systems supporting the delivery of conservation technical assistance by the United States Department of Agriculture (USDA) to agricultural producers on working lands have become increasingly complex over the past 25 years. They are constrained by inconsistent coordination of domain knowl...

  15. ON-BOARD MONITORING OF TECHNICAL STATE FOR POWER UNITS OF WHEELED AND TRACKED VEHICLES

    Directory of Open Access Journals (Sweden)

    Yu. D. Karpievich

    2016-01-01

    Full Text Available The paper considers new methodologies pertaining to on-board diagnosis of wear-out rate for friction linings of a clutch driven disk and friction discs of a hydraulic press clutch of transmission gear boxes which are based on physical process that uses friction work as an integrated indicator. A new methodology in determination of life-span rate for engine oil has been developed in the paper. The paper presents block schematic diagrams for on-board monitoring of technical state for power units of wheeled and tracked vehicles. Usage of friction work as an integrated indicator for determination of wear-out rate for friction linings of clutch driven disk and friction discs of a haydraulic press clutch makes it possible timely at any operational period of wheeled and tracked vehicles to determine their residual operation life and forecast their replacement.While taking volume of the used fuel for determination of engine oil life-span rate it permits quickly and effectively at any operational period of wheeled and tracked vehicles to determine residual useful life of the engine oil and also forecast its replacement.

  16. Summary of new distribution records for mosquito species in the United States and Canada for the period 1981-99.

    Science.gov (United States)

    Darsie, R F; Ward, R A

    2000-03-01

    In order to elucidate the recent spread of mosquito species in the United States and Canada, a summary of new records for states and provinces has been prepared to include those reported mostly from 1981 to 1998, although some records before 1989 are also given. We are reporting 132 new records for 58 species of mosquitoes.

  17. The Development Strategies for the Management Models of the Electronic Documents and Records in the United States, United Kingdom and Australia

    Directory of Open Access Journals (Sweden)

    Chiu-Yen Lin

    2015-06-01

    Full Text Available The trend toward electronic government has espoused a large quantity of electronic records, which challenge the existing records management models in the modern countries. This paper describes and compares the development and transition toward electronic records management in the United States, United Kingdom, and Australia to show how the three advanced countries evolved the government records management practices. The analysis emphasized on the holistic policy initiative perspective and compared the directives and regulations, research and development programs and plans, the emerging structures of governance, staffing and professional training, and risk management provisions. The comparison may shed lights on the government electronic management in the other countries. [Article content in Chinese

  18. 36 CFR 1235.10 - What records do agencies transfer to the National Archives of the United States?

    Science.gov (United States)

    2010-07-01

    ... transfer to the National Archives of the United States? 1235.10 Section 1235.10 Parks, Forests, and Public... NATIONAL ARCHIVES OF THE UNITED STATES General Transfer Requirements § 1235.10 What records do agencies transfer to the National Archives of the United States? Agencies must transfer to the National Archives......

  19. 40 CFR 60.1370 - What records must I keep for municipal waste combustion units that use activated carbon?

    Science.gov (United States)

    2010-07-01

    ... waste combustion units that use activated carbon? 60.1370 Section 60.1370 Protection of Environment... Recordkeeping § 60.1370 What records must I keep for municipal waste combustion units that use activated carbon? For municipal waste combustion units that use activated carbon to control dioxins/furans or...

  20. 40 CFR 60.1855 - What records must I keep for municipal waste combustion units that use activated carbon?

    Science.gov (United States)

    2010-07-01

    ... waste combustion units that use activated carbon? 60.1855 Section 60.1855 Protection of Environment... waste combustion units that use activated carbon? For municipal waste combustion units that use activated carbon to control dioxins/furans or mercury emissions, you must keep records of five items:...

  1. 40 CFR 62.15310 - What records must I keep for municipal waste combustion units that use activated carbon?

    Science.gov (United States)

    2010-07-01

    ... waste combustion units that use activated carbon? 62.15310 Section 62.15310 Protection of Environment... for municipal waste combustion units that use activated carbon? For municipal waste combustion units that use activated carbon to control dioxins/furans or mercury emissions, you must keep records of...

  2. New Lithostratigraphic Unit Records an Ediacaran Glaciation in Mato Grosso State, Brazil: Serra Azul Formation

    Directory of Open Access Journals (Sweden)

    Francisco Egídio Cavalcante Pinho

    2008-10-01

    Full Text Available A new succession of diamictites and siltstones was found above post-Marinoan carbonates from the Araras Group in the northern Paraguay Belt (Brazil, in discontinuous outcrops. This new stratigraphic unit, named Serra Azul Formation in this work, has a variable thickness reaching up to 300 meters. The diamictites were deposited in the first 70 m and present glacial evidences, while the siltstones represent the upper part of the succession and show some sandstone layers towards the top of the succession. This glacial record is the youngest Neoproterozoic glacial event that has been found on South America and probably is related to Gaskiers Glaciation (582 Ma.

  3. Evaluation of EDR-3 vibration, shock, temperature, and humidity recording unit

    Science.gov (United States)

    Rees, Kevin G.; Mondale, C. F.

    1990-07-01

    The purpose of this evaluation was to determine if the self-contained, off-the-shelf, Environmental Data Recorder 3 (EDR-3) could be qualified to monitor shock, vibration, and temperature during rail transportation of space shuttle solid rocket components. The evaluation testing started in November 1989 and continued until June 1990. Two EDR-3 units were used to monitor both on- and off-plant shipments of shuttle components. In addition, extensive testing was performed at Thiokol's Vibration Test facility, T-53. Testing demonstrated that the EDR-3 is capable of successfully monitoring actual shipments of solid rocket hardware. Thiokol metrology has verified the accuracy of temperature monitoring. In addition, calibrated shock/vibration testing demonstrated that the EDR-3 does accurately record acceleration. It is recommended that the vendor modify the EDR-3 data recovery system to allow remote communication via a 30-foot cable. This would permit communication with the unit mounted on a case segment after a rail car cover is installed. The vendor will make this change and produce a new model, designated EDR-3-10. It is further recommended that Thiokol qualify the EDR-3-10 for transportation monitoring of redesigned solid rocket motor (RSRM) components.

  4. NOAA Climate Data Record (CDR) of Advanced Microwave Sounding Unit (AMSU)-A Brightness Temperature, Version 1

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NOAA Climate Data Record (CDR) for Advanced Microwave Sounding Unit-A (AMSU-A) brightness temperature in "window channels". The data cover a time period from...

  5. Record of Decision for the Rocky Mountain Arsenal On-Post Operable Unit in southern Adams County, Commerce City, Colorado.

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This Record of Decision (ROD) presents the selected remedial action for the Rocky Mountain Arsenal (RMA) On-Post Operable Unit in southern Adams County (east of...

  6. An analysis of technical aspects of the arthroscopic Bankart procedure as performed in the United States.

    Science.gov (United States)

    Burks, Robert T; Presson, Angela P; Weng, Hsin-Yi

    2014-10-01

    The purpose of this study was to investigate the intersurgeon variation in technical aspects of performing an arthroscopic Bankart repair. A unique approach with experienced equipment representatives from 3 different arthroscopic companies was used. Experienced representatives were identified by DePuy Mitek, Smith & Nephew, and Arthrex and filled out questionnaires on how their surgeons performed arthroscopic Bankart procedures. This was performed in a blinded fashion with no knowledge of the identities of the specific surgeons or representatives by us. A video on different aspects of the procedure was observed by each representative before filling out the questionnaire to help standardize responses. Data were collected using REDCap (Research Electronic Data Capture). Data were analyzed as an infrequent observation with 0% to 30% of representatives reporting the observation; sometimes, 31% to 70% reporting the observation; and often, greater than 70% of representatives reporting. Seventy-six percent of representatives had 6 or more years of arthroscopic experience. Forty-three percent of representatives reported that their surgeons use 3 portals for the procedure often. Forty-four percent reported that viewing was performed exclusively from the posterior portal while the surgeon was performing the repair. Seventy-three percent reported that the Hill-Sachs lesion was observed often, and 61% reported that the posterior labrum was evaluated often before the repair. Only 25% of representatives reported that the Bankart lesion was extensively released and mobilized often. Thirty-three percent reported 3 anchors as being used often. Seventy-five percent reported biocomposite anchors as being used often. Single-loaded anchors were reported as being used often by 47%. Eighty-one percent reported that sutures were placed in a simple fashion. Eighty-three percent reported the use of any posterior sutures or anchors for additional plication as infrequent. There is significant

  7. 32 CFR Appendix D to Part 286 - DD Form 2086-1, “Record of Freedom of Information (FOI) Processing Cost for Technical Data”

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false DD Form 2086-1, âRecord of Freedom of Information (FOI) Processing Cost for Technical Dataâ D Appendix D to Part 286 National Defense Department of... FREEDOM OF INFORMATION ACT PROGRAM REGULATION Pt. 286, App. D Appendix D to Part 286—DD Form...

  8. A method for unit recording in the lumbar spinal cord during locomotion of the conscious adult rat

    DEFF Research Database (Denmark)

    Berg, Rune W; Chen, Ming-Teh; Huang, Hsueh-Chen;

    2009-01-01

    Extracellular recordings from single units in the brain, for example the neocortex, have proven feasible in moving, awake rats, but have not yet been possible in the spinal cord. Single-unit activity during locomotor-like activity in reduced preparations from adult cats and rats have provided...

  9. Eielson Air Force Base operable unit 2 and other areas record of decision

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, R.E.; Smith, R.M.

    1994-10-01

    This decision document presents the selected remedial actions and no action decisions for Operable Unit 2 (OU2) at Eielson Air Force Base (AFB), Alaska, chosen in accordance with state and federal regulations. This document also presents the decision that no further action is required for 21 other source areas at Eielson AFB. This decision is based on the administrative record file for this site. OU2 addresses sites contaminated by leaks and spills of fuels. Soils contaminated with petroleum products occur at or near the source of contamination. Contaminated subsurface soil and groundwater occur in plumes on the top of a shallow groundwater table that fluctuates seasonally. These sites pose a risk to human health and the environment because of ingestion, inhalation, and dermal contact with contaminated groundwater. The purpose of this response is to prevent current or future exposure to the contaminated groundwater, to reduce further contaminant migration into the groundwater, and to remediate groundwater.

  10. On the Edge of Life, II: House Officer Struggles Recorded in an Intensive Care Unit Journal.

    Science.gov (United States)

    Sekeres, Mikkael A.; Stern, Theodore A.

    2002-10-01

    BACKGROUND: In a general hospital, few clinical settings match the intensity of the intensive care unit (ICU) experience. Clinical rotations in ICUs elicit and emphasize the struggles house officers face on a daily basis throughout their training. METHOD: These struggles were recorded by hundreds of residents in a journal maintained in one Medical ICU for the past 20 years. We systematically reviewed these unsolicited entries to develop categories that define and illustrate common stressors. RESULTS: Stressors for house officers include isolation, insecurity, care for the terminally ill, sleep deprivation, and long work weeks. CONCLUSION: By placing the struggles of house staff in context, trainees and their residency training programs can be prepared for the intensity of the experience and for work in clinical practice settings that follows completion of training.

  11. Integrating the Electronic Health Record into high-fidelity interprofessional intensive care unit simulations.

    Science.gov (United States)

    Gold, Jeffrey A; Tutsch, Alycia S R; Gorsuch, Adriel; Mohan, Vishnu

    2015-01-01

    With the rapid adoption of electronic health records (EHR), there is a growing appreciation for the central role they play in clinical decision making and team communication, with many studies documenting new safety issues with integration of the EHR into the clinical enterprise. To study these issues, we created a high-fidelity simulation instance of our clinical EHR. In this paper, we describe the impact of integrating the EHR into high-fidelity, interprofessional intensive care unit (ICU) simulations, and the errors induced. We found a number of safety issues directly related to the EHR including alert fatigue, negative impacts on interprofessional communication, and problems with selective data gathering, and these issues were present for all members of the interprofessional team. Through successful integration of the EHR into high-fidelity team-based simulations, we now have an infrastructure to focus educational initiative and deploy informatics solutions to mitigate these safety issues.

  12. Quality Outcomes in the Surgical Intensive Care Unit after Electronic Health Record Implementation.

    Science.gov (United States)

    Flatow, V H; Ibragimova, N; Divino, C M; Eshak, D S A; Twohig, B C; Bassily-Marcus, A M; Kohli-Seth, R

    2015-01-01

    The electronic health record (EHR) is increasingly viewed as a means to provide more coordinated, patient-centered care. Few studies consider the impact of EHRs on quality of care in the intensive care unit (ICU) setting. To evaluate key quality measures of a surgical intensive care unit (SICU) following implementation of the Epic EHR system in a tertiary hospital. A retrospective chart review was undertaken to record quality indicators for all patients admitted to the SICU two years before and two years after EHR implementation. Data from the twelve-month period of transition to EHR was excluded. We collected length of stay, mortality, central line associated blood stream infection (CLABSI) rates, Clostridium difficile (C. diff.) colitis rates, readmission rates, and number of coded diagnoses. To control for variation in the patient population over time, the case mix indexes (CMIs) and APACHE II scores were also analyzed. There was no significant difference in length of stay, C. diff. colitis, readmission rates, or case mix index before and after EHR. After EHR implementation, the rate of central line blood stream infection (CLABSI) per 1 000 catheter days was 85% lower (2.16 vs 0.39; RR, 0.18; 95% CI, 0.05 to 0.61, p < .005), and SICU mortality was 28% lower (12.2 vs 8.8; RR, 1.35; 95% CI, 1.06 to 1.71, p < .01). Moreover, after EHR there was a significant increase in the average number of coded diagnoses from 17.8 to 20.8 (p < .000). EHR implementation was statistically associated with reductions in CLABSI rates and SICU mortality. The EHR had an integral role in ongoing quality improvement endeavors which may explain the changes in CLABSI and mortality, and this invites further study of the impact of EHRs on quality of care in the ICU.

  13. Risk assessment analysis of the future technical unit dedicated to the evaluation and treatment of motor disabilities.

    Science.gov (United States)

    Grelier, S; Thetio, M; Quentin, V; Achache, V; Sanchez, N; Leroux, V; Durand, E; Pequignot, R

    2011-03-01

    The National Hospital of Saint Maurice (HNSM) for Physical Medicine and Rehabilitation aims at strengthening its position as a pivot rehabilitation and physical therapy center. The opening in 2011 of a new unit for the evaluation and treatment of motor disabilities meets this objective. This project includes several parts: clinical, financial, architectural, organizational, applied clinical research as well as dealing with medical equipments and information system. This study focuses on the risk assessment of this future technical unit. This study was conducted by a group of professionals working for the hospital. It started with the design of a functional model to better comprehend the system to be analyzed. Risk assessment consists in confronting this functional model to a list of dangers in order to determine the vulnerable areas of the system. Then the team designed some scenarios to identify the causes, securities barriers and consequences in order to rank the risks. The analysis targeted various dangers, e.g. political, strategic, financial, economical, marketing, clinical and operational. The team identified more than 70 risky scenarios. For 75% of them the criticality level was deemed initially tolerable and under control or unacceptable. The implementation of an action plan for reducing the level of risks before opening this technical unit brought the system down to an acceptable level at 66%. A year prior to opening this technical unit for the evaluation and treatment of motor disabilities, conducting this preliminary risk assessment, with its exhaustive and rigorous methodology, enabled the concerned professionals to work together around an action plan for reducing the risks. 2011 Elsevier Masson SAS. All rights reserved.

  14. A multimodal micro-optrode combining field and single unit recording, multispectral detection and photolabeling capabilities.

    Science.gov (United States)

    Dufour, Suzie; Lavertu, Guillaume; Dufour-Beauséjour, Sophie; Juneau-Fecteau, Alexandre; Calakos, Nicole; Deschênes, Martin; Vallée, Réal; De Koninck, Yves

    2013-01-01

    Microelectrodes have been very instrumental and minimally invasive for in vivo functional studies from deep brain structures. However they are limited in the amount of information they provide. Here, we describe a, aluminum-coated, fibre optic-based glass microprobe with multiple electrical and optical detection capabilities while retaining tip dimensions that enable single cell measurements (diameter ≤10 µm). The probe enables optical separation from individual cells in transgenic mice expressing multiple fluorescent proteins in distinct populations of neurons within the same deep brain nucleus. It also enables color conversion of photoswitchable fluorescent proteins, which can be used for post-hoc identification of the recorded cells. While metal coating did not significantly improve the optical separation capabilities of the microprobe, the combination of metal on the outside of the probe and of a hollow core within the fiber yields a microelectrode enabling simultaneous single unit and population field potential recordings. The extended range of functionalities provided by the same microprobe thus opens several avenues for multidimensional structural and functional interrogation of single cells and their surrounding deep within the intact nervous system.

  15. A regenerative microchannel device for recording multiple single-unit action potentials in awake, ambulatory animals.

    Science.gov (United States)

    Srinivasan, Akhil; Tipton, John; Tahilramani, Mayank; Kharbouch, Adel; Gaupp, Eric; Song, Chao; Venkataraman, Poornima; Falcone, Jessica; Lacour, Stéphanie P; Stanley, Garrett B; English, Arthur W; Bellamkonda, Ravi V

    2016-02-01

    Despite significant advances in robotics, commercially advanced prosthetics provide only a small fraction of the functionality of the amputated limb that they are meant to replace. Peripheral nerve interfacing could provide a rich controlling link between the body and these advanced prosthetics in order to increase their overall utility. Here, we report on the development of a fully integrated regenerative microchannel interface with 30 microelectrodes and signal extraction capabilities enabling evaluation in an awake and ambulatory rat animal model. In vitro functional testing validated the capability of the microelectrodes to record neural signals similar in size and nature to those that occur in vivo. In vitro dorsal root ganglia cultures revealed striking cytocompatibility of the microchannel interface. Finally, in vivo, the microchannel interface was successfully used to record a multitude of single-unit action potentials through 63% of the integrated microelectrodes at the early time point of 3 weeks. This marks a significant advance in microchannel interfacing, demonstrating the capability of microchannels to be used for peripheral nerve interfacing.

  16. The United Kingdom 2009 Swine Flu Outbreak As Recorded in Real Time by General Practitioners

    Directory of Open Access Journals (Sweden)

    Hershel Jick

    2011-01-01

    Full Text Available Background. Initially the course of the 2009 swine flu pandemic was uncertain and impossible to predict with any confidence. An effective prospective data resource exists in the United Kingdom (UK that could have been utilized to describe the scope and extent of the swine flu outbreak as it unfolded. We describe the 2009 swine flu outbreak in the UK as recorded daily by general practitioners and the potential use of this database for real-time tracking of flu outbreaks. Methods. Using the General Practice Research Database, a real-time general practice, electronic database, we estimated influenza incidence from July 1998 to September 2009 according to age, region, and calendar time. Results. From 1998 to2008, influenza outbreaks regularly occurred yearly from October to March, but did not typically occur from April to September until the swine flu outbreak began in April 2009. The weekly incidence rose gradually, peaking at the end of July, and the outbreak had largely dissipated by early September. Conclusions. The UK swine flu outbreak, recorded in real time by a large group of general practitioners, was mild and limited in time. Simultaneous online access seemed feasible and could have provided additional clinical-based evidence at an early planning stage of the outbreak.

  17. A multimodal micro-optrode combining field and single unit recording, multispectral detection and photolabeling capabilities.

    Directory of Open Access Journals (Sweden)

    Suzie Dufour

    Full Text Available Microelectrodes have been very instrumental and minimally invasive for in vivo functional studies from deep brain structures. However they are limited in the amount of information they provide. Here, we describe a, aluminum-coated, fibre optic-based glass microprobe with multiple electrical and optical detection capabilities while retaining tip dimensions that enable single cell measurements (diameter ≤10 µm. The probe enables optical separation from individual cells in transgenic mice expressing multiple fluorescent proteins in distinct populations of neurons within the same deep brain nucleus. It also enables color conversion of photoswitchable fluorescent proteins, which can be used for post-hoc identification of the recorded cells. While metal coating did not significantly improve the optical separation capabilities of the microprobe, the combination of metal on the outside of the probe and of a hollow core within the fiber yields a microelectrode enabling simultaneous single unit and population field potential recordings. The extended range of functionalities provided by the same microprobe thus opens several avenues for multidimensional structural and functional interrogation of single cells and their surrounding deep within the intact nervous system.

  18. Electronic Health Records Data and Metadata: Challenges for Big Data in the United States.

    Science.gov (United States)

    Sweet, Lauren E; Moulaison, Heather Lea

    2013-12-01

    This article, written by researchers studying metadata and standards, represents a fresh perspective on the challenges of electronic health records (EHRs) and serves as a primer for big data researchers new to health-related issues. Primarily, we argue for the importance of the systematic adoption of standards in EHR data and metadata as a way of promoting big data research and benefiting patients. EHRs have the potential to include a vast amount of longitudinal health data, and metadata provides the formal structures to govern that data. In the United States, electronic medical records (EMRs) are part of the larger EHR. EHR data is submitted by a variety of clinical data providers and potentially by the patients themselves. Because data input practices are not necessarily standardized, and because of the multiplicity of current standards, basic interoperability in EHRs is hindered. Some of the issues with EHR interoperability stem from the complexities of the data they include, which can be both structured and unstructured. A number of controlled vocabularies are available to data providers. The continuity of care document standard will provide interoperability in the United States between the EMR and the larger EHR, potentially making data input by providers directly available to other providers. The data involved is nonetheless messy. In particular, the use of competing vocabularies such as the Systematized Nomenclature of Medicine-Clinical Terms, MEDCIN, and locally created vocabularies inhibits large-scale interoperability for structured portions of the records, and unstructured portions, although potentially not machine readable, remain essential. Once EMRs for patients are brought together as EHRs, the EHRs must be managed and stored. Adequate documentation should be created and maintained to assure the secure and accurate use of EHR data. There are currently a few notable international standards initiatives for EHRs. Organizations such as Health Level Seven

  19. Unified English Braille in the United Kingdom: Part 1--Examination by Technical Expert Braille Users

    Science.gov (United States)

    Cryer, Heather; Home, Sarah; Morley Wilkins, Sarah

    2013-01-01

    The Unified English Braille (UEB) code has already been adopted by various countries. To inform the decision about UK adoption, a suite of research was carried out with UK braille readers and other stakeholders. Previous research indicates that readers of technical braille codes may be most affected by a move to UEB. In this study, six technical…

  20. Career and Technical Education in United States Prisons: What Have We Learned?

    Science.gov (United States)

    Ward, Shakoor A.

    2009-01-01

    This essay examines the effects of Career and Technical Education (CTE) in U.S. prisons by looking at research that has conflicting results and inferences. Although the opposing positions are mainly represented by two studies, this essay includes literature review of historical studies representing opposing views regarding the effects of CTE in…

  1. Use and Production of Digital Information and Knowledge in Technical University Education - Co-operation of Faculty and Support Units

    Directory of Open Access Journals (Sweden)

    Anna-Kaarina Kairamo

    2004-12-01

    Full Text Available The rapidly changing educational landscape is of increasing importance in university teaching. Universities in Finland are responsible for research and education based on research. Traditionally information and support services related to using and producing knowledge, support research, and education has mostly been seen purely from the students´ perspective. Teaching in universities is still a hidden individual activity, and, as such, challenges the support units to reach and interact with the academic community. This paper will review the aspects influencing the use and production of digital information and knowledge in technical university education; examples illustrating the experiences will be given.

  2. Psychoactive drug advertising: a comparison of technical information from three countries: Brazil, United States and United Kingdom

    Directory of Open Access Journals (Sweden)

    Patricia de Carvalho Mastroianni

    Full Text Available CONTEXT AND OBJECTIVE: Studies carried out in the 1970s and 1980s showed that there were country-dependent disparities in the information given for the same drug in medical advertisements. National and international regulations have been published to do away with such disparities and to foster the rational use of drugs. The purpose of this study was to compare the information contained in psychoactive drug advertisements published in psychiatric journals in Brazil, the United States and the United Kingdom, before and subsequent to the publication of the United States Export Act, in 1986, the WHO criteria, in 1988, and the Brazilian Sanitary Surveillance Agency Resolution no. 102, in 2000. TYPE OF STUDY AND SETTING: Content analysis, at Centro Brasileiro de Informações sobre Drogas Psicotrópicas (Cebrid. METHODS: We gathered advertisements from Brazilian, American and British psychiatry periodicals published before and after each ruling. We analyzed a total of twenty-four Brazilian advertisements that were for the same psychoactive drugs as advertised in American and/or British publications from the same period. RESULTS: We observed that Brazilian advertisements omitted information on usage restrictions, such as contraindications, adverse reactions, interactions, warnings and precautions, and that such information was present in American and British advertisements. CONCLUSIONS: The data suggest that disparities in the information given for the same drug still persist. The information depends on the country in which each drug is marketed. The legislation is insufficient for eradicating such disparities.

  3. Predictive models for pressure ulcers from intensive care unit electronic health records using Bayesian networks.

    Science.gov (United States)

    Kaewprag, Pacharmon; Newton, Cheryl; Vermillion, Brenda; Hyun, Sookyung; Huang, Kun; Machiraju, Raghu

    2017-07-05

    We develop predictive models enabling clinicians to better understand and explore patient clinical data along with risk factors for pressure ulcers in intensive care unit patients from electronic health record data. Identifying accurate risk factors of pressure ulcers is essential to determining appropriate prevention strategies; in this work we examine medication, diagnosis, and traditional Braden pressure ulcer assessment scale measurements as patient features. In order to predict pressure ulcer incidence and better understand the structure of related risk factors, we construct Bayesian networks from patient features. Bayesian network nodes (features) and edges (conditional dependencies) are simplified with statistical network techniques. Upon reviewing a network visualization of our model, our clinician collaborators were able to identify strong relationships between risk factors widely recognized as associated with pressure ulcers. We present a three-stage framework for predictive analysis of patient clinical data: 1) Developing electronic health record feature extraction functions with assistance of clinicians, 2) simplifying features, and 3) building Bayesian network predictive models. We evaluate all combinations of Bayesian network models from different search algorithms, scoring functions, prior structure initializations, and sets of features. From the EHRs of 7,717 ICU patients, we construct Bayesian network predictive models from 86 medication, diagnosis, and Braden scale features. Our model not only identifies known and suspected high PU risk factors, but also substantially increases sensitivity of the prediction - nearly three times higher comparing to logistical regression models - without sacrificing the overall accuracy. We visualize a representative model with which our clinician collaborators identify strong relationships between risk factors widely recognized as associated with pressure ulcers. Given the strong adverse effect of pressure ulcers

  4. The United States Department of Energy Office of Industrial Technology`s Technology Benefits Recording System

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, K.R.; Moore, N.L.

    1994-09-01

    The U.S. Department of Energy (DOE) Office of Industrial Technology`s (OIT`s) Technology Benefits Recording System (TBRS) was developed by Pacific Northwest Laboratory (PNL). The TBRS is used to organize and maintain records of the benefits accrued from the use of technologies developed with the assistance of OIT. OIT has had a sustained emphasis on technology deployment. While individual program managers have specific technology deployment goals for each of their ongoing programs, the Office has also established a separate Technology Deployment Division whose mission is to assist program managers and research and development partners commercialize technologies. As part of this effort, the Technology Deployment Division developed an energy-tracking task which has been performed by PNL since 1977. The goal of the energy-tracking task is to accurately assess the energy savings impact of OIT-developed technologies. In previous years, information on OIT-sponsored technologies existed in a variety of forms--first as a hardcopy, then electronically in several spreadsheet formats that existed in multiple software programs. The TBRS was created in 1993 for OIT and was based on information collected in all previous years from numerous industrial contacts, vendors, and plants that have installed OIT-sponsored technologies. The TBRS contains information on technologies commercialized between 1977 and the present, as well as information on emerging technologies in the late development/early commercialization stage of the technology life cycle. For each technology, details on the number of units sold and the energy saved are available on a year-by-year basis. Information regarding environmental benefits, productivity and competitiveness benefits, or impact that the technology may have had on employment is also available.

  5. United States Air Force Graduate Student Research Program. 1989 Program Technical Report. Volume 1

    Science.gov (United States)

    1989-12-01

    Report as Dr. Barbara Alvin *** School of Aerospace Medicine 93 Investigation of the Release of Sudarkodi Alagarsamy Glutamate and Dynorphin A(1-8) by...Universal Energy Systems for their administration and especially Barbara Vincent for her patience and help with my security clearance. I would like to...rapid solution of several technical problems. Finally, I would like to express my gratitude to my research director, Dr. William R. Carper for his

  6. United States Air Force Graduate Student Research Program. 1989 Program Technical Report. Volume 3

    Science.gov (United States)

    1989-12-01

    just enough alignment in the organism passively along the field lines. Many animals, such as insects, fish, birds , reptiles , and mammals , have been...STUDENT RESEARCH PROGRAM 1989 PROGRAM TECHNICAL REPORT UNIVERSAL ENERGY SYSTEMS, INC. VOLUME III of III Program Director, UES Program Manager , AFOSR...Bldg. Assigned: Flight Dynamics Laboratory Wilberforce, OH 45384 (513) 376-6435 Dagmar Fertl Degree: BS Texas A&M Univ. Specialty: Biology Wildlife

  7. INDEPENDENT TECHNICAL ASSESSMENT OF MANAGEMENT OF STORMWATER AND WASTEWATER AT THE SEPARATIONS PROCESS RESEARCH UNIT (SPRU) DISPOSITION PROJECT, NEW YORK

    Energy Technology Data Exchange (ETDEWEB)

    Abitz, R.; Jackson, D.; Eddy-Dilek, C.

    2011-06-27

    The U.S. Department of Energy (DOE) is currently evaluating the water management procedures at the Separations Process Research Unit (SPRU). The facility has three issues related to water management that require technical assistance: (1) due to a excessive rainfall event in October, 2010, contaminated water collected in basements of G2 and H2 buildings. As a result of this event, the contractor has had to collect and dispose of water offsite; (2) The failure of a sump pump at a KAPL outfall resulted in a Notice of Violation issued by the New York State Department of Environment and Conservation (NYSDEC) and subsequent Consent Order. On-site water now requires treatment and off-site disposition; and (3) stormwater infiltration has resulted in Strontium-90 levels discharged to the storm drains that exceed NR standards. The contractor has indicated that water management at SPRU requires major staff resources (at least 50 persons). The purpose of this review is to determine if the contractor's technical approach warrants the large number of staff resources and to ensure that the technical approach is compliant and in accordance with federal, state and NR requirements.

  8. Comparison of Standards and Technical Requirements of Grid-Connected Wind Power Plants in China and the United States

    Energy Technology Data Exchange (ETDEWEB)

    Gao, David Wenzhong [Alternative Power Innovations, LLC; Muljadi, Eduard [National Renewable Energy Lab. (NREL), Golden, CO (United States); Tian, Tian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Miller, Mackay [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wang, Weisheng [China Electric Power Research Inst. (China)

    2016-09-01

    The rapid deployment of wind power has made grid integration and operational issues focal points in industry discussions and research. Compliance with grid connection standards for wind power plants (WPPs) is crucial to ensuring the reliable and stable operation of the electric power grid. This report compares the standards for grid-connected WPPs in China to those in the United States to facilitate further improvements in wind power standards and enhance the development of wind power equipment. Detailed analyses of power quality, low-voltage ride-through capability, active power control, reactive power control, voltage control, and wind power forecasting are provided to enhance the understanding of grid codes in the two largest markets of wind power. This study compares WPP interconnection standards and technical requirements in China to those in the United States.

  9. Multiple unit activity recorded longitudinally in rats from pubescence to old age.

    Science.gov (United States)

    Malmo, H P; Malmo, R B

    1982-01-01

    Longitudinal multiple unit activity (MUA) recordings of excellent quality over time periods as long as 26 months are described. The validity of the method was demonstrated by showing persistence of specific and idiosyncratic MUA responses to controlled sensory stimulation over these long time periods. This longitudinal MUA method was used to study level of localization neuronal activity as a function of aging. In agreement with deoxyglucose data from Sokoloff's laboratory, we found significant age-related declines in inferior and superior colliculi. In addition, our results showed the advantage of a longitudinal method over a cross-sectional one in following progressive changes into old age. The further declines in midbrain MUA level (though not in forebrain level) from middle age to old age that we observed were highly significant. The deoxyglucose method, on the other hand, had failed to show this kind of progression in those midbrain sites, probably because of a survival effect, a common sampling artifact in cross-sectional studies of aging.

  10. A movable microelectrode array for chronic basal ganglia single-unit electrocorticogram co-recording in freely behaving rats.

    Science.gov (United States)

    Zheng, Xiaobin; Zeng, Jia; Chen, Ting; Lin, Yuanxiang; Yu, Lianghong; Li, Ying; Lin, Zhangya; Wu, Xiyue; Chen, Fuyong; Kang, Dezhi; Zhang, Shizhong

    2014-09-01

    The basal ganglia-cortical circuits are important for information process to brain function. However, chronic recording of single-unit activities in the basal ganglia nucleus has not yet been well established. We present a movable bundled microwire array for chronic subthalamic nucleus (STN) single-unit electrocorticogram co-recording. The electrode assembly contains a screw-advanced microdrive and a microwire array. The array consists of a steel guide tube, five recording wires and one referenced wire which form the shape of a guiding hand, and one screw electrode for cortico-recording. The electrode can acquire stable cortex oscillation-driven STN firing units in rats under different behaving conditions for 8 weeks. We achieved satisfying signal-to-noise ratio, portions of cells retaining viability, and spike waveform similarities across the recording sections. Using this method, we investigated neural correlations of the basal ganglia-cortical circuits in different behaving conditions. This method will become a powerful tool for multi-region recording to study normal statements or movement disorders.

  11. Reliable assessment of general surgeons' non-technical skills based on video-recordings of patient simulated scenarios

    DEFF Research Database (Denmark)

    Spanager, Lene; Beier-Holgersen, Randi; Dieckmann, Peter;

    2013-01-01

    Nontechnical skills are essential for safe and efficient surgery. The aim of this study was to evaluate the reliability of an assessment tool for surgeons' nontechnical skills, Non-Technical Skills for Surgeons dk (NOTSSdk), and the effect of rater training.......Nontechnical skills are essential for safe and efficient surgery. The aim of this study was to evaluate the reliability of an assessment tool for surgeons' nontechnical skills, Non-Technical Skills for Surgeons dk (NOTSSdk), and the effect of rater training....

  12. Humanistic Elements in the Educational Practice at a United States Sub-Baccalaureate Technical College

    Directory of Open Access Journals (Sweden)

    Carsten Schmidtke

    2017-08-01

    Full Text Available Humanism has never been able to establish a firm place in technical education, which remains predominantly pragmatist in response to industry needs, certification requirements and educational standardisation. However, after a period of decline, humanism has made somewhat of a comeback as part of the movement toward student-centred education. Research conducted at a technical college showed that although . This research indicated that including humanistic elements in educational practice will enable instructors to be more effective in helping students to develop skills in relation to team work, problem-solving, systems improvement, lifelong learning and other areas that are becoming increasingly necessary for success in the workplace. The include a constructivist approach with a focus on contextual teaching and learning using situated cognition, cognitive apprenticeships, anchored instruction and authentic assessment. At the same time, some suggestions for improving professional development for teachers by using a Gestalt approach along with self-study in the context of learning communities have been discussed.

  13. An in vitro method for recording single unit afferent activity from mesenteric nerves innervating isolated segments of rat ileum.

    Science.gov (United States)

    Sharkey, K A; Cervero, F

    1986-04-01

    A technique has been developed for recording single unit afferent activity from mesenteric nerves in isolated segments of rat distal ileum in vitro. The preparation consists of a 3-cm segment of ileum, containing a single neurovascular bundle, held horizontally in an organ bath. One end of the segment is attached to a tension transducer to record changes in longitudinal tension of the gut muscle and the other is connected to a pressure transducer to record changes in intra-luminal pressure. Electromyographic activity of the smooth muscle is recorded using glass-insulated tungsten microelectrodes inserted in the wall of the gut. Afferent nerve activity is recorded with a monopolar platinum wire electrode from filaments of the mesenteric nerves that run between the artery and vein supplying the segment. This preparation permits the detailed analysis of the electrical activity of intestinal afferent nerve fibres correlated with mechanical and chemical events occurring naturally in the gut or imposed experimentally on it.

  14. Dynamics of national forests assessed using the Landsat record: Case studies in eastern United States

    Science.gov (United States)

    Huang, C.; Goward, S.N.; Schleeweis, K.; Thomas, N.; Masek, J.G.; Zhu, Z.

    2009-01-01

    The national forests (NFs) in the United States are protected areas managed for multiple purposes, and therefore are subject to both natural and anthropogenic disturbances. Monitoring forest changes arising from such disturbances and the post-disturbance recovery processes is essential for assessing the conditions of the NFs and the effectiveness of management approaches. In this study, we used time series stacks of Landsat images (LTSS) to evaluate the dynamics of seven NFs in eastern United States, including the De Soto NF, the Talladega NF, the Francis Marion NF, and the Uwharrie NF in southeastern U.S., and the Chequamegon NF, the Hiawatha NF, and the Superior NF in northern U.S. Each LTSS consisted of 12-14 Landsat images acquired for the same location, spanning from 1984 to 2006 with a nominal interval of one image every 2??years. Each LTSS was analyzed using a vegetation change tracker (VCT) algorithm to map forest disturbance. Accuracy assessments of the derived disturbance maps revealed that they had overall accuracy values of about 80%, with most of the disturbance classes having user's accuracies ranging from 70% to 95%. The producer's accuracies were generally lower, with the majority being in the range between 50% and 70%. While this may suggest that the disturbance maps could slightly underestimate disturbances, a more detailed assessment of the omission errors revealed that the majority of the disagreements were due to minor disturbances like thinning or storm damages that were identified by the image analysts but were not captured by the VCT algorithm. The derived disturbance year maps revealed that while each of the seven NFs consisted of 90% or more forest land, significant portions of the forests were disturbed since 1984. Mapped disturbances accounted for about 30%-45% of total land area in the four NFs in southeastern U.S. and about 10%-20% in the three NFs in northern U.S. The disturbance rates were generally higher in the buffer zones

  15. 36 CFR 1235.46 - What electronic media may be used for transferring records to the National Archives of the United...

    Science.gov (United States)

    2010-07-01

    ... used for transferring records to the National Archives of the United States? 1235.46 Section 1235.46... TRANSFER OF RECORDS TO THE NATIONAL ARCHIVES OF THE UNITED STATES Transfer Specifications and Standards... to the National Archives of the United States. (See 36 CFR 1236.28 for the requirements governing...

  16. Development of the Self-Powered Extravehicular Mobility Unit Extravehicular Activity Data Recorder

    Science.gov (United States)

    Bernard, Craig; Hill, Terry R.; Murray, Sean; Wichowski, Robert; Rosenbush, David

    2012-01-01

    The Self-Powered Extravehicular Mobility Unit (EMU) Extravehicular Activity (EVA) Data Recorder (SPEEDR) is a field-programmable gate array (FPGA)-based device designed to collect high-rate EMU Primary Life Support Subsystem (PLSS) data for download at a later time. During EVA, the existing EMU PLSS data downlink capability is one data packet every 2 minutes and is subject to bad packets or loss of signal. Higher-rate PLSS data is generated by the Enhanced Caution and Warning System but is not normally captured or distributed. Access to higher-rate data will increase the capability of EMU anomaly resolution team to pinpoint issues remotely, saving crew time by reducing required call-down Q&A and on-orbit diagnostic activities. With no Space Shuttle flights post Fiscal Year 2011 (FY11), and potentially limited down-mass capability, the ISS crew and ground support personnel will have to be capable of on-orbit operations to maintain, diagnose, repair, and return to service EMU hardware, possibly through 2028. Collecting high-rate EMU PLSS data during both intravehicular activity (IVA) and EVA operations will provide trending analysis for life extension and/or predictive performance. The SPEEDR concept has generated interest as a tool/technology that could be used for other International Space Station subsystems or future exploration-class space suits where hardware reliability/availability is critical and low/variable bandwidth may require store then forward methodology. Preliminary work in FY11 produced a functional prototype consisting of an FPGA evaluation board, custom memory/interface circuit board, and custom software. The SPEEDR concept includes a stand-alone battery that is recharged by a computer Universal Serial Bus (USB) port while data are being downloaded.

  17. Science-practice nexus for landslide surveying: technical training for local government units in Indonesia

    Science.gov (United States)

    Alam, A. L.; Hespiantoro, S.; Dyar, D.; Balzer, D.; Kuhn, D.; Torizin, J.; Fuchs, M.; Kastl, S.; Anhorn, J.

    2017-02-01

    The Indonesian archipelago is prone to various geological hazards on an almost day to day basis. In order to mitigate disaster risk and reduce losses, the government uses its unique setup of ministerial training institutions. The Centre for Development of Human Resources in Geology, Mineral and Coal offers different level of technical training to local governments in order to provide them with the necessary means to understand geological hazards, mitigate risks, and hence close the gap between local and national governments. One key factor has been the continuous incorporation of new scientific knowledge into their training curricula. The paper presents benefits and challenges of this science-practice nexus using the standardised landslide survey as one example where mobile technology has been introduced to the training just recently.

  18. Teacher Professional Learning in the United States: Case Studies of State Policies and Strategies. Technical Report

    Science.gov (United States)

    Jaquith, Ann; Mindich, Dan; Wei, Ruth Chung; Darling-Hammond, Linda

    2010-01-01

    This report is the third of a three-phase research study of teacher professional learning opportunities in the United States. In this third phase of the research, the authors conducted case studies of four professionally active states to get a deeper look at the policy frameworks that support professional development in those states. These…

  19. Regional impacts of technical change: the case of structural particleboard in the United States.

    Science.gov (United States)

    Zhi Xu; David N. Bengston; Hans M. Gregersen; Allen L. Lundgren

    1992-01-01

    Analyzes the regional impacts of research benefits in the United States due to the introduction of structural particleboard. The distribution of consumer benefits, producer benefits, direct employment impacts, and changes in wood requirements are analyzed for the four census regions. The distribution of benefits is found to differ widely between regions, indicating...

  20. Mobile Intensive Care Unit: Technical and clinical aspects of interhospital critical care transport

    NARCIS (Netherlands)

    van Lieshout, E.J.

    2016-01-01

    The Mobile Intensive Care Unit (MICU) is a combination of i) a team of critical care nurse, physician and ambulance driver, ii) a MICU-trolley (i.e. equipped with cardiovascular monitor, mechanical ventilator, syringe pumps etc. indispensable for safe transport and iii) an Intensive Care ambulance.

  1. Mobile Intensive Care Unit: Technical and clinical aspects of interhospital critical care transport

    NARCIS (Netherlands)

    van Lieshout, E.J.

    2016-01-01

    The Mobile Intensive Care Unit (MICU) is a combination of i) a team of critical care nurse, physician and ambulance driver, ii) a MICU-trolley (i.e. equipped with cardiovascular monitor, mechanical ventilator, syringe pumps etc. indispensable for safe transport and iii) an Intensive Care ambulance.

  2. Chronic neural probe for simultaneous recording of single-unit, multi-unit, and local field potential activity from multiple brain sites

    Science.gov (United States)

    Pothof, F.; Bonini, L.; Lanzilotto, M.; Livi, A.; Fogassi, L.; Orban, G. A.; Paul, O.; Ruther, P.

    2016-08-01

    Objective. Drug resistant focal epilepsy can be treated by resecting the epileptic focus requiring a precise focus localisation using stereoelectroencephalography (SEEG) probes. As commercial SEEG probes offer only a limited spatial resolution, probes of higher channel count and design freedom enabling the incorporation of macro and microelectrodes would help increasing spatial resolution and thus open new perspectives for investigating mechanisms underlying focal epilepsy and its treatment. This work describes a new fabrication process for SEEG probes with materials and dimensions similar to clinical probes enabling recording single neuron activity at high spatial resolution. Approach. Polyimide is used as a biocompatible flexible substrate into which platinum electrodes and leads are integrated with a minimal feature size of 5 μm. The polyimide foils are rolled into the cylindrical probe shape at a diameter of 0.8 mm. The resulting probe features match those of clinically approved devices. Tests in saline solution confirmed the probe stability and functionality. Probes were implanted into the brain of one monkey (Macaca mulatta), trained to perform different motor tasks. Suitable configurations including up to 128 electrode sites allow the recording of task-related neuronal signals. Main results. Probes with 32 and 64 electrode sites were implanted in the posterior parietal cortex. Local field potentials and multi-unit activity were recorded as early as one hour after implantation. Stable single-unit activity was achieved for up to 26 days after implantation of a 64-channel probe. All recorded signals showed modulation during task execution. Significance. With the novel probes it is possible to record stable biologically relevant data over a time span exceeding the usual time needed for epileptic focus localisation in human patients. This is the first time that single units are recorded along cylindrical polyimide probes chronically implanted 22 mm deep into the

  3. Technical and clinical analysis of microEEG: a miniature wireless EEG device designed to record high-quality EEG in the emergency department.

    Science.gov (United States)

    Omurtag, Ahmet; Baki, Samah G Abdel; Chari, Geetha; Cracco, Roger Q; Zehtabchi, Shahriar; Fenton, André A; Grant, Arthur C

    2012-09-24

    We describe and characterize the performance of microEEG compared to that of a commercially available and widely used clinical EEG machine. microEEG is a portable, battery-operated, wireless EEG device, developed by Bio-Signal Group to overcome the obstacles to routine use of EEG in emergency departments (EDs). The microEEG was used to obtain EEGs from healthy volunteers in the EEG laboratory and ED. The standard system was used to obtain EEGs from healthy volunteers in the EEG laboratory, and studies recorded from patients in the ED or ICU were also used for comparison. In one experiment, a signal splitter was used to record simultaneous microEEG and standard EEG from the same electrodes. EEG signal analysis techniques indicated good agreement between microEEG and the standard system in 66 EEGs recorded in the EEG laboratory and the ED. In the simultaneous recording the microEEG and standard system signals differed only in a smaller amount of 60 Hz noise in the microEEG signal. In a blinded review by a board-certified clinical neurophysiologist, differences in technical quality or interpretability were insignificant between standard recordings in the EEG laboratory and microEEG recordings from standard or electrode cap electrodes in the ED or EEG laboratory. The microEEG data recording characteristics such as analog-to-digital conversion resolution (16 bits), input impedance (>100MΩ), and common-mode rejection ratio (85 dB) are similar to those of commercially available systems, although the microEEG is many times smaller (88 g and 9.4 × 4.4 × 3.8 cm). Our results suggest that the technical qualities of microEEG are non-inferior to a standard commercially available EEG recording device. EEG in the ED is an unmet medical need due to space and time constraints, high levels of ambient electrical noise, and the cost of 24/7 EEG technologist availability. This study suggests that using microEEG with an electrode cap that can be applied easily and quickly can

  4. United States Air Force Summer Faculty Research Program (1987). Program Technical Report. Volume 2.

    Science.gov (United States)

    1987-12-01

    level. Secondly, the Gibbs free energy at a given location in the sample is taken to be comprised of two main contributions: the free energy per unit...ise tneab Itre ldt bs ofidth vv)tc, l ,ecto e sCin trw C’narv e hasi Proab. em ofeaccowies toihte r ptheent i stu o yn" o fase zero> mTy e

  5. Public Workshop, Staff Technical Meeting with Applicant on Geysers Unit 17

    Energy Technology Data Exchange (ETDEWEB)

    Schiller, Wendy E.

    1978-02-21

    The overall purpose of this meeting is to discuss the report that was sent to PG and E on February 1st discussing Geysers 17. The Commission has reviewed all of the existing data, the majority of the existing data that have gone through both Lake County and through the CPUC regarding 17, looked at the existing data to see what, if any, additional would be required to file and expeditiously process a Notice of Intention on Geysers Unit 17.

  6. United States Air Force Graduate Student Summer Support Program 1986. Program Technical Report. Volume 2

    Science.gov (United States)

    1986-12-01

    PROGRAM PROJECT TASK WORK UNIT Building 410 ELEMENT NO. NO. NO. NO. Bolling AFB, DC 20332 6l1O2F 33(. 5 11. TITLE (Inclusde Security Clasification ) us...H Byfr *(.. *’i ~rvs Vari ance arlu jt s A~ :i Z. 1r _ _:_F ’easureamerts cf EEG Act i vi t Y, �. 4,, Carie . f.R. G3. anrd ;:rost, .£.*"QSil

  7. Critical evaluation of the nonradiological environmental technical specifications. Volume 4. San Onofre Nuclear Generating Station, Unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Adams, S.M.; Cunningham, P.A.; Gray, D.D.; Kumar, K.D.

    1976-08-10

    A comprehensive study of the data collected as part of the environmental Technical Specifications program for Unit 1 of the San Onofre Nuclear Generating Station (SONGS 1) was conducted for the Office of Nuclear Regulatory Research of the U.S. Nuclear Regulatory Commission. The program included an analysis of the hydrothermal and ecological monitoring data collected during 1975. The hydrothermal analysis includes a discussion of models used in plume predictions prior to plant operation and an evaluation of the present hydrothermal monitoring program. The ecological evaluation was directed toward reviewing the strengths and weaknesses of the various sampling programs designed to monitor the planktonic, benthic, and nektonic communities inhabiting the inshore coastal area in the vicinity of San Onofre.

  8. The boot software of the control unit of the near infrared spectrograph of the Euclid space mission: technical specification

    Science.gov (United States)

    Gómez-Sáenz-de-Tejada, Jaime; Toledo-Moreo, Rafael; Colodro-Conde, Carlos; Pérez-Lizán, David; Fernández-Conde, Jesús; Sánchez-Prieto, Sebastián.

    2016-07-01

    The Near Infrared Spectrograph and Photometer (NISP) is one of the instruments on board the ESA EUCLID mission. The Boot Software (BSW) is in charge of initialization and communications after a reset occurs at hard- ware level. The Universidad Politecnica de Cartagena and Instituto de Astrofisica de Canarias are responsible of the Instrument Control Unit of the NISP (NI-ICU) in the Euclid Consortium. The NI-ICU BSW is developed by Universidad de Alcaĺa, and its main functions are: communication with the S/C for memory management, self-tests and start of a patchable Application Software (ASW). This paper presents the NI-ICU BSW status of definition and design at the end of the Technical Specification phase.

  9. United States Air Force Summer Faculty Research Program, 1988. Program Technical Report. Volume 4

    Science.gov (United States)

    1988-12-01

    trips and provided much needed support. I thank Dr. Newcomb, Mr. Dick Vigue, Mrs. Barbara Eaton, and Capt. Dimitroff for reviewing this manuscript...species of stinging wasp, nearly all cases 144-10 were caper wasps. These records were examined to determine the frequency of wasp control relative to other...Phys. Chem., 88, p2320(1984). 12. Siemens A.-G. (Hans J. Henkel), Ger. Pat. 1,234,341, February 16, 1967. 13. R. G. Lawler and P. F. Barbara

  10. A VIRTUAL TECHNICAL SYSTEMS AUDIT OF RESEARCH QUALITY ASSURANCE AND RECORD MANAGEMENT SYSTEMS IN ORD, U.S EPA

    Science.gov (United States)

    NHEERL conducts technical systems audits (TSAs) on its research projects. The findings are reported by the QA Manager (QAM) to the Director of QA (DQA) as Exemplary Findings (things the QA Team liked); Corrective Actions (things that must be corrected immediately); and Areas for...

  11. Technical note: Validation of sensor-recorded lying bouts in lactating dairy cows using a 2-sensor approach.

    Science.gov (United States)

    Kok, A; van Knegsel, A T M; van Middelaar, C E; Hogeveen, H; Kemp, B; de Boer, I J M

    2015-11-01

    Lying behavior is a relevant indicator for the evaluation of cow welfare. Lying can be recorded automatically by data loggers attached to one of the hind legs of a cow. A threshold for the duration of a lying bout (LB) record is required, however, to discard false records caused by horizontal leg movements, such as scratching. Previously determined thresholds for similar sensors ranged from 25s to 4min. We aimed to validate LB recorded by the IceQube sensor (with IceManager software; IceRobotics, South Queensferry, UK) and to determine a threshold to distinguish true from false LB records in lactating dairy cows. A novel method of validation, which does not require time-consuming behavioral observations, was used to generate a larger data set with potentially more incidental short LB records. Both hind legs of 28 lactating dairy cows were equipped with an IceQube sensor for a period of 6d and used as each other's validation. Classification of LB records as true (actual LB) or false (recorded while standing) was based on 3 assumptions. First, all standing records (absence of LB records) were assumed to occur while standing. Second, false LB records due to short leg movements could not occur in both hind legs simultaneously. Third, true LB only occurred if the LB records of the paired sensors coincided. False LB records constituted 4% of the records. Based on a maximum accuracy of 0.99, a minimum duration of LB records of 33 s was determined, implying a sensitivity of 0.99 and a specificity of 0.98. Applying this threshold of 33 s hardly affected estimates of daily lying time, but improved estimates of frequency and mean duration of LB for individual cows. The importance of distinguishing short LB was demonstrated specifically for detection of calving. The 2-sensor approach, using sensor outputs on both hind legs as each other's validation, is a time-efficient method to validate LB records that can be applied to different sensors and husbandry conditions.

  12. Record of Decision for Tank Farm Soil and INTEC Groundwater, Operable Unit 3-14

    Energy Technology Data Exchange (ETDEWEB)

    L. S. Cahn

    2007-05-16

    This decision document presents the selected remedy for Operable Unit (OU) 3-14 tank farm soil and groundwater at the Idaho Nuclear Technology and Engineering Center (INTEC), which is located on the Idaho National Laboratory (INL) Site. The tank farm was initially evaluated in the OU 3-13 Record of Decision (ROD), and it was determined that additional information was needed to make a final decision. Additional information has been obtained on the nature and extent of contamination in the tank farm and on the impact to groundwater. The selected remedy was chosen in accordance with the Comprehensive Environmental Response, Liability and Compensation Act of 1980 (CERCLA) (42 USC 9601 et seq.), as amended by the Superfund Amendments and Reauthorization Act of 1986 (Public Law 99-499) and the National Oil and Hazardous Substances Pollution Contingency Plan (40 CFR 300). The selected remedy is intended to be the final action for tank farm soil and groundwater at INTEC. The response action selected in this ROD is necessary to protect the public health, welfare, or the environment from actual or threatened releases of hazardous substances into the environment. Such a release or threat of release may present an imminent and substantial endangerment to public health, welfare, or the environment. The remedial actions selected in this ROD are designed to reduce the potential threats to human health and the environment to acceptable levels. In addition, DOE-ID, EPA, and DEQ (the Agencies) have determined that no action is necessary under CERCLA to protect public health, welfare, or the environment at 16 sites located outside the tank farm boundary. The purposes of the selected remedy are to (1) contain contaminated soil as the radionuclides decay in place, (2) isolate current and future workers and biological receptors from contact with contaminated soil, and (3) restore the portion of Snake River Plain Aquifer contaminated by INTEC releases to Idaho Ground Water Quality

  13. Feedback controlled piezo-motor microdrive for accurate electrode positioning in chronic single unit recording in behaving mice.

    Science.gov (United States)

    Yang, Sungwook; Cho, Jeiwon; Lee, Semin; Park, Kitae; Kim, Jinseok; Huh, Yeowool; Yoon, Eui-Sung; Shin, Hee-Sup

    2011-02-15

    The microdrive is one of the most essential tools for extracellular, single-unit recordings in freely behaving animals to detect and isolate the single-unit activities from brain regions of interest. Due to the increasing number of neuroscience research projects using genetically engineered mice, the demand for effective recording devices in freely moving mice is also increasing. Although manually and automatically operated microdrive devices are available, they are limited in terms of size, weight, accuracy, manipulability, and convenience for single-unit recording in mice. The present study proposed a novel microdrive that employs a small, lightweight piezo-motor and a magnetoresistive (MR) sensor with a closed-loop position feedback control system. The total weight of the device is 1.82 g, which is perfectly suitable for application to mice. Most importantly, the proposed microdrive is capable of monitoring and adjusting electrode movement on-line by integrating a closed-loop feedback control system, which enhances the accuracy of micro-advancement of the electrode by utilizing position feedback. The performance of this newly developed microdrive was extensively evaluated for both mechanical and physiological concerns at both free-loading and various-loading conditions, including agarose gel matrix and then the hippocampus and thalamus of mice. In summary, this proposed microdrive can enhance the quality of recording single unit activities in freely moving mice in terms of the size and weight of the device, the convenience and accuracy of manipulation, and, most of all, in isolating single neurons and recording stability by providing accurate positioning of an electrode.

  14. OCCURRENCE OF FAULT RECORDS OF NURSING CARE IN A HOSPITAL MEDICAL UNIT

    Directory of Open Access Journals (Sweden)

    Paula Bresolin

    2013-09-01

    Full Text Available The nursing records have value as a procedural document, source of inquiry and teaching tool. It is worth mentioning that, the records are actions performed through care processes, generating revenue for the institutions.The objective of this study was to identify the major record failures of nursing care. The survey was conducted in an Adult Clinic of a private hospital in Caxias do Sul, in the period of March to April, 2012. Data were collected through the reporting of the auditorship service and through the application of a questionnaire to the nursing staff. The main problems found were the lack of scheduling, checks and nursing records, the incorrect materials and drugs request by nursing, mistakes in prescriptions and imcomplete forms. From the problems identified it is suggested the intensification of continuing education on nursing records and further studies to identify the economic value lost by glosses in hospital bills.

  15. Using smart phone video to supplement communication of radiology imaging in a neurosurgical unit: technical note.

    Science.gov (United States)

    Shivapathasundram, Ganeshwaran; Heckelmann, Michael; Sheridan, Mark

    2012-04-01

    The use of smart phones within medicine continues to grow at the same rate as mobile phone technology continues to evolve. One use of smart phones within medicine is in the transmission of radiological images to consultant neurosurgeons who are off-site in an emergency setting. In our unit, this has allowed quick, efficient, and safe communication between consultant neurosurgeon and trainees, aiding in rapid patient assessment and management in emergency situations. To describe a new means of smart phone technology use in the neurosurgical setting, where the video application of smart phones allows transfer of a whole series of patient neuroimaging via multimedia messaging service to off-site consultant neurosurgeons. METHOD/TECHNIQUE: Using the video application of smart phones, a 30-second video of an entire series of patient neuroimaging was transmitted to consultant neurosurgeons. With this information, combined with a clinical history, accurate management decisions were made. This technique has been used on a number of emergency situations in our unit to date. Thus far, the imaging received by consultants has been a very useful adjunct to the clinical information provided by the on-site trainee, and has helped expedite management of patients. While the aim should always be for the specialist neurosurgeon to review the imaging in person, in emergency settings, this is not always possible, and we feel that this technique of smart phone video is a very useful means for rapid communication with neurosurgeons.

  16. Data Stewardship: Managing Personally Identifiable Information in Electronic Student Education Records. SLDS Technical Brief 2. NCES 2011-602

    Science.gov (United States)

    National Center for Education Statistics, 2010

    2010-01-01

    The growth of electronic student data in America's education system has focused attention on the ways these data are collected, processed, stored, and used. The use of records in Statewide Longitudinal Data Systems to follow the progress of individual students over time requires maintaining student education records that include information that…

  17. Technical work plan for Surface Impoundments Operable Unit engineering support studies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    This document provides a comprehensive work plan which, when utilized as a data collection guide for field activities, will provide the necessary information required to complete a report on geotechnical properties of the sediments contained in the Surface Impoundments Operable Unit at Oak Ridge National Laboratory in Oak Ridge, Tennessee. Detailed guidance is provided for the following activities: collection of samples from the impoundments; compressive strength testing of the raw sediments; compressive strength testing of the structurally modified (lime and cement additives) sediments; testing for sediment physical properties and settling rates; testing for sediment dewatering characteristics; testing for radiation activity during the field work; testing for polymer additions that may enhance settling. The work plan additionally provides guidance and examples for the preparation of documents necessary to establish readiness for safe and satisfactory performance of the field activities. An outline for the format requested for a report of these data is also provided.

  18. In-plant source term measurements at Fort Calhoun Station - Unit 1. Topical technical report

    Energy Technology Data Exchange (ETDEWEB)

    Dyer, N.C.; Keller, J.H.; Bunting, R.L.; Motes, B.G.; Croney, S.T.

    1978-07-01

    Data obtained from an in-plant source term measurement program are presented. The objective of this program is to provide operational data that can be used in the generic evaluation of plant system design in the licensing process and for updating of the calculational models used by the NRC staff in their evaluation of radioactive waste management systems for operating pressurized water reactors. A data base is provided for radioisotope inventory in plant systems, radioactive waste management system performance, and source terms for both liquid and gaseous systems. Data presented were obtained at the Fort Calhoun Station - Unit 1, operated by the Omaha Public Power District (OPPD), located at Blair, Nebraska. In-plant measurements were conducted during the time period from August, 1976 through February 1977. This plant is the first of a planned series of six (6) operating PWR's to be studied.

  19. Critical evaluation of the nonradiological environmental technical specifications. Volume 3. Peach Bottom Atomic Power Station Units 2 and 3

    Energy Technology Data Exchange (ETDEWEB)

    Adams, S.M.; Cunningham, P.A.; Gray, D.D.; Kumar, K.D.; Witten, A.J.

    1976-08-10

    A comprehensive study of the data collected as part of the environmental Technical Specifications program for Units 2 and 3 of the Peach Bottom Nuclear Power Plant was conducted for the Office of Regulatory Research of the U.S. Nuclear Regulatory Commission. The program included an analysis of both the hydrothermal and ecological monitoring data collected from 1967 through 1976. Specific recommendations are made for improving both the present hydrothermal and ecological monitoring programs. Hydrothermal monitoring would be improved by more complete reporting of in-plant operating parameters. In addition, the present boat surveys could be discontinued, and monitoring efforts could be directed toward expanding the present thermograph network. Ecological monitoring programs were judged to be of high quality because standardized collection techniques, consistent reporting formats, and statistical analyses were performed on all of the data and were presented in an annual report. Sampling for all trophic groups was adequate for the purposes of assessing power plant induced perturbations. Considering the extensive period of preoperational data (six years) and operational data (three years) available for analysis, consideration could be given to reducing monitoring effort after data have been collected for a period when both units are operating at full capacity. In this way, an assessment of the potential ecological impact of the Peach Bottom facility can be made under conditions of maximum plant induced perturbations.

  20. Using High-Technology Simulators to Prepare Anesthesia Providers Before Implementation of a New Electronic Health Record Module: A Technical Report.

    Science.gov (United States)

    Weintraub, Ari Y; Deutsch, Ellen S; Hales, Roberta L; Buchanan, Newton A; Rock, Whitney L; Rehman, Mohamed A

    2017-06-01

    Learning to use a new electronic anesthesia information management system can be challenging. Documenting anesthetic events, medication administration, and airway management in an unfamiliar system while simultaneously caring for a patient with the vigilance required for safe anesthesia can be distracting and risky. This technical report describes a vendor-agnostic approach to training using a high-technology manikin in a simulated clinical scenario. Training was feasible and valued by participants but required a combination of electronic and manual components. Further exploration may reveal simulated patient care training that provides the greatest benefit to participants as well as feedback to inform electronic health record improvements.

  1. Completeness of maternal smoking status recording during pregnancy in United Kingdom primary care data.

    Directory of Open Access Journals (Sweden)

    Nafeesa N Dhalwani

    Full Text Available BACKGROUND: Given the health impacts of smoking during pregnancy and the opportunity for primary healthcare teams to encourage pregnant smokers to quit, our primary aim was to assess the completeness of gestational smoking status recording in primary care data and investigate whether completeness varied with women's characteristics. As a secondary aim we assessed whether completeness of recording varied before and after the introduction of the Quality and Outcomes Framework (QOF. METHODS: In The Health Improvement Network (THIN database we calculated the proportion of pregnancies ending in live births or stillbirths where there was a recording of maternal smoking status for each year from 2000 to 2009. Logistic regression was used to assess variation in the completeness of maternal smoking recording by maternal characteristics, before and after the introduction of QOF. RESULTS: Women had a record of smoking status during the gestational period in 28% of the 277,552 pregnancies identified. In 2000, smoking status was recorded in 9% of pregnancies, rising to 43% in 2009. Pregnant women from the most deprived group were 17% more likely to have their smoking status recorded than pregnant women from the least deprived group before QOF implementation (OR 1.17, 95% CI 1.10-1.25 and 42% more likely afterwards (OR 1.42, 95% CI 1.37-1.47. A diagnosis of asthma was related to recording of smoking status during pregnancy in both the pre-QOF (OR 1.63, 95% CI 1.53-1.74 and post-QOF periods (OR 2.08, 95% CI 2.02-2.15. There was no association between having a diagnosis of diabetes and recording of smoking status during pregnancy pre-QOF however, post-QOF diagnosis of diabetes was associated with a 12% increase in recording of smoking status (OR 1.12, 95% CI 1.05-1.19. CONCLUSION: Recording of smoking status during pregnancy in primary care data is incomplete though has improved over time, especially after the implementation of the QOF, and varies by maternal

  2. Recording of severe mental illness in United Kingdom primary care, 2000-2010.

    Directory of Open Access Journals (Sweden)

    Sarah Hardoon

    Full Text Available BACKGROUND: There is increasing emphasis on primary care services for individuals with severe mental illnesses (SMI, including schizophrenia, bipolar disorder, and other non-organic psychotic disorders. However we lack information on how many people receive these different diagnoses in primary care. Primary care databases offer an opportunity to explore the recording of new SMI diagnoses in representative general practices. METHODS: We used data from The UK Health Improvement Network (THIN primary care database including longitudinal patient records for individuals aged over 16 years from 437 general practices. We determined the annual GP recorded rate of first diagnosis of SMI by age, gender, social deprivation and urbanicity between 2000 and 2010. RESULTS: We identified 10,520 individuals with a first record of schizophrenia, bipolar disorder or other non-organic psychosis among 4,164,794 patients. This corresponded to a rate of first diagnosis of 46.4 per 100,000 person years at risk (PYAR (95% CI 45.4 to 47.4 in the 16-65 age group. The rate of first record of schizophrenia was 9.2 per 100,000 PYAR (95% CI 8.7 to 9.6 in this age group, bipolar disorder was 15.0 per 100,000 PYAR (95% CI 14.4 to 15.5 and other non-organic psychotic disorder was 22.3 per 100,000 PYAR (95% CI 21.6 to 23.0. CONCLUSIONS: The rates of GP recorded SMI in primary care records were broadly comparable to incidence rates from previous epidemiological studies of SMI and show similar patterns by socio-demographic characteristics. However there were some differences by specific diagnoses. GPs may be recording rates that are higher than those used to commission services.

  3. An inventory of United States and Canadian growth record sets: preliminary report.

    Science.gov (United States)

    Hunter, W S; Baumrind, S; Moyers, R E

    1993-06-01

    A listing and description of longitudinal craniofacial growth record sets currently extant on the North American continent is provided. An argument is made for the preservation of these resources and for the generation of a pooled or shared image base of duplicate craniofacial physical records. This is a preliminary report and is assumed to be incomplete. In an effort to improve our accuracy and completeness, we invite corrections and additions.

  4. Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings

    Science.gov (United States)

    Patel, Paras R.; Na, Kyounghwan; Zhang, Huanan; Kozai, Takashi D. Y.; Kotov, Nicholas A.; Yoon, Euisik; Chestek, Cynthia A.

    2015-08-01

    Objective. Single carbon fiber electrodes (d = 8.4 μm) insulated with parylene-c and functionalized with PEDOT:pTS have been shown to record single unit activity but manual implantation of these devices with forceps can be difficult. Without an improvement in the insertion method any increase in the channel count by fabricating carbon fiber arrays would be impractical. In this study, we utilize a water soluble coating and structural backbones that allow us to create, implant, and record from fully functionalized arrays of carbon fibers with ˜150 μm pitch. Approach. Two approaches were tested for the insertion of carbon fiber arrays. The first method used a poly(ethylene glycol) (PEG) coating that temporarily stiffened the fibers while leaving a small portion at the tip exposed. The small exposed portion (500 μm-1 mm) readily penetrated the brain allowing for an insertion that did not require the handling of each fiber by forceps. The second method involved the fabrication of silicon support structures with individual shanks spaced 150 μm apart. Each shank consisted of a small groove that held an individual carbon fiber. Main results. Our results showed that the PEG coating allowed for the chronic implantation of carbon fiber arrays in five rats with unit activity detected at 31 days post-implant. The silicon support structures recorded single unit activity in three acute rat surgeries. In one of those surgeries a stacked device with three layers of silicon support structures and carbon fibers was built and shown to readily insert into the brain with unit activity on select sites. Significance. From these studies we have found that carbon fibers spaced at ˜150 μm readily insert into the brain. This greatly increases the recording density of chronic neural probes and paves the way for even higher density devices that have a minimal scarring response.

  5. An Automated Individual Training Record Management System (Prototype) United States Marine Corps

    Science.gov (United States)

    1984-03-01

    F OM A:CRNGQIAS ADDITIVE CASE I(MUNIT) = ID RESTORE F CM A:DRNGQIAS ADDITIVE CASE I( UNIT) = ’’ RESTORE F BCM A:BNRNGQTA ADDITIVE IECASE ERASE a 2,15...ADDITIVE CASE IR(UNIT) E RES TOEE F FCM A:BNENGQTA ADDITIVE IECAS E ERASE a 2,15 SAY "BIFLE RANGE QUOTA SCRATCH PAD"l 2 a4 5 SAY I"SFACE BELCW THIS

  6. Technical-Economic Evaluation of a Cogeneration Unit Considering Carbon Emission Savings

    Directory of Open Access Journals (Sweden)

    Ana Christina Ferreira

    2014-06-01

    Full Text Available The support of combined heat and power production systems has gained policy attention, because these are often considered to be less polluting and more efficient than conventional energy conversion systems. As a consequence, the potential market for these energy systems that contribute to reduce greenhouse gas emissions and to enhance energy security on a national level, is shifting from large-scale existing units to small and micro-size emerging technologies. This paper presents a numerical model based on a cost-benefit analysis used to design an optimal cogeneration system for a small-scale building application, considering the Portuguese context and the comparison with the harmonized efficiency reference values for the separate production of electricity and useful heat. The model includes the identification of the objective function terms (i.e., the elements involved in the financial analysis across the system lifetime and the economic evaluation of costs and benefits of the combined heat and power production system. The economic viability of cogeneration systems significantly depends on system technology, client energy requirements and support schemes implemented in the respective countries. A strategic approach is necessary to adequately embed the new technology as a feasible solution in terms of investment and operational costs. Only by matching the energy supply to the needs and expectations of the energy users, it will be possible to improve the market competitiveness of these alternative power production plants. The optimal solution disclosed a positive annual worth, which is higher if the carbon emission savings are monetized. In addition, the optimal system represents a more efficient way to produce useful heat and electricity (i.e. a positive primary energy saving and to reduce gas emissions. A cost-benefit analysis can be applied for the techno-economic evaluation of a CHP system by assessing the monetary socio-environmental costs

  7. A Technical Evaluation of Wireless Connectivity from Patient Monitors to an Anesthesia Information Management System During Intensive Care Unit Surgery.

    Science.gov (United States)

    Simpao, Allan F; Galvez, Jorge A; England, W Randall; Wartman, Elicia C; Scott, James H; Hamid, Michael M; Rehman, Mohamed A; Epstein, Richard H

    2016-02-01

    Surgical procedures performed at the bedside in the neonatal intensive care unit (NICU) at The Children's Hospital of Philadelphia were documented using paper anesthesia records in contrast to the operating rooms, where an anesthesia information management system (AIMS) was used for all cases. This was largely because of logistical problems related to connecting cables between the bedside monitors and our portable AIMS workstations. We implemented an AIMS for documentation in the NICU using wireless adapters to transmit data from bedside monitoring equipment to a portable AIMS workstation. Testing of the wireless AIMS during simulation in the presence of an electrosurgical generator showed no evidence of interference with data transmission. Thirty NICU surgical procedures were documented via the wireless AIMS. Two wireless cases exhibited brief periods of data loss; one case had an extended data gap because of adapter power failure. In comparison, in a control group of 30 surgical cases in which wired connections were used, there were no data gaps. The wireless AIMS provided a simple, unobtrusive, portable alternative to paper records for documenting anesthesia records during NICU bedside procedures.

  8. A Comparative Study of the Trends in Career and Technical Education among European Countries, the United States, and the Republic of China.

    Science.gov (United States)

    Wu, Robert T. Y.

    2003-01-01

    Compares developmental trends, theories, and philosophical perspectives in career and technical education in Europe, the United States, and Taiwan. Describes the European model as based on social action and workplace reform, the U.S./Taiwanese model as focused on human resource development and economic growth. (Contains 21 references.) (SK)

  9. Identifying Rates of Emigration in the United States Using Administrative Earnings Records

    Directory of Open Access Journals (Sweden)

    Jonathan A. Schwabish

    2011-01-01

    Full Text Available This paper undertakes a new strategy to estimate emigration rates among US immigrants by inferring the probability of emigration using longitudinal administrative earnings data. Two groups of emigrants are evaluated separately: those who emigrate from the United States and those who leave both the United States and the Social Security system. About 1.0 to 1.5 percent of the foreign-born population emigrate from the USA every year, and between about 0.8 and 1.2 percent of foreign-born workers emigrate from the Social Security system. Regression analysis suggests that immigrants with lower earnings are more likely to emigrate and that the likelihood of emigrating from the United States increases with age, but is unchanged for those leaving the US Social Security system.

  10. Synthesis and application for optical recording of a new diarylethene having a benzene unit

    Energy Technology Data Exchange (ETDEWEB)

    Yan Peijian; Pu Shouzhi; Liu Weijun; Liu Gang, E-mail: pushouzhi@tsinghua.org.cn [Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang 330013 (China)

    2011-02-01

    A novel photochromic diarylethene was synthesized and its photochromism, fluorescence properties have been investigated. This compound exhibited good photochromism and functioned as a fluorescence switch upon alternating irradiation with UV and visible light both in solution and in PMMA film. When diarylethene was used as recording medium, the results demonstrated that the diarylethene compound had attractive properties for high density optical storage.

  11. A combined long-term recording system for single-unit activity and neurotransmitter efflux of a brain slice

    Science.gov (United States)

    Sheu, Y. H.; Young, M. S.

    1998-04-01

    A combined long-term measurement and recording system for neurotransmission research of brain slices is presented in this study. This system, based on the IBM PC or compatible computer, is capable of simultaneously measuring and recording both single-unit neural electropotential signals and the electrochemical signals of neurotransmitter efflux from the same neuron in a brain slice for long periods of time (time limited largely by hard disk capacity, 100 h or more not being unreasonable with contemporary hardware) using a single carbon microelectrode for both measurements. The combined long-term recording system uses a simple switching circuit to switch periodically the single microelectrode between two data acquisition subsystems, one for electrochemical data and one for electrophysiological data. The simple switching circuit separates the electrophysiological signals and electrochemical signals, overcoming the traditional interference problem caused by the two different measuring techniques. Software designed for the proposed system allows easy reconstruction of the full time course of the compressed measured data and easy, simultaneous display of both types of signals on the same time scale. On-line and recorded displays are available. Test results of a practical implementation of the proposed system verify that the combined long-term recording system meets actual requirements for electrophysiological and neurochemical research.

  12. Tales of the Supernatural: A Selected List of Recordings Made in the United States and Placed in the Archive of Folk Culture. Folk Archive Finding Aid.

    Science.gov (United States)

    Delcambre, Angie C., Comp.; And Others

    This finding aid is a selected list of supernatural-related narratives recorded in the United States and held in the Archive of Folk Culture of the Library of Congress. Brief descriptions of the recordings are accompanied by identification numbers. Information about listening to or ordering any of the listed recordings is available from the…

  13. Paleotempestological Record of Intense Storms for the Northern Gulf of Mexico, United States

    Science.gov (United States)

    Bregy, J. C.; Wallace, D. J.

    2016-12-01

    Hurricanes Camille (1969) and Katrina (2005) are two intense hurricanes that made landfall in nearly the same location in Mississippi. Fully understanding the risks associated with hurricane impacts is challenging due to a short instrumental record. Paleotempestology can be used to extend the hurricane record significantly. An advective settling model can be used to back-calculate storm surge heights as a function of sediment transport distance, particle settling velocity, and gravity. We collected cores in a pond and an adjacent beach in coastal Mississippi. Loss-on-ignition and grain-size analyses were performed on these cores, and a Bayesian statistical age-depth model using 137Cs and 14C dating was employed to determine core chronology. Camille and Katrina were used to calibrate the inverse sediment transport model, and similar coarse-grained deposits at depth were identified. Calculated paleosurge intensities from the model indicate values similar in magnitude to Camille over the 2500-yr record. However, given that the shoreline was likely further seaward from its modern location approximately 700 yr BP, these estimates are conservative. Intense hurricane impacts have not varied over multi-millennial time periods, as evidenced by our average annual direct landfall probability (0.48%) closely matching previously published studies from the Gulf of Mexico. However, over shorter timescales, intense hurricanes occurred between 900 to 600 and 2200 to 1900 yr BP, while a period of quiescent storm activity occurred between 1900 to 900 yr BP. The reduction in hurricane activity around 600 yr BP is corroborated by previously published records of sites in the Gulf of Mexico. A known southerly shift in the Loop Current occurred circa 600 yr BP, suggesting that local-scale climate processes are more important in controlling hurricane variability observed between paleotempestological sites from the area rather than larger-scale climate phenomena.

  14. TECHNICAL EVALUATION OF SOIL REMEDIATION ALTERNATIVES AT THE BUILDING 812 OPERABLE UNIT, LAWRENCE LIVERMORE NATIONAL LABORATORY SITE 300

    Energy Technology Data Exchange (ETDEWEB)

    Eddy-Dilek, C.; Miles, D.; Abitz, R.

    2009-08-14

    The Department of Energy Livermore Site Office requested a technical review of remedial alternatives proposed for the Building 812 Operable Unit, Site 300 at the Lawrence Livermore National Laboratory. The team visited the site and reviewed the alternatives proposed for soil remediation in the draft RI/FS and made the following observations and recommendations. Based on the current information available for the site, the team did not identify a single technology that would be cost effective and/or ecologically sound to remediate DU contamination at Building 812 to current remedial goals. Soil washing is not a viable alternative and should not be considered at the site unless final remediation levels can be negotiated to significantly higher levels. This recommendation is based on the results of soil washing treatability studies at Fernald and Ashtabula that suggest that the technology would only be effective to address final remediation levels higher than 50 pCi/g. The technical review team identified four areas of technical uncertainty that should be resolved before the final selection of a preferred remedial strategy is made. Areas of significant technical uncertainty that should be addressed include: (1) Better delineation of the spatial distribution of surface contamination and the vertical distribution of subsurface contamination in the area of the firing table and associated alluvial deposits; (2) Chemical and physical characterization of residual depleted uranium (DU) at the site; (3) Determination of actual contaminant concentrations in air particulates to support risk modeling; and (4) More realistic estimation of cost for remedial alternatives, including soil washing, that were derived primarily from vendor estimates. Instead of conducting the planned soil washing treatability study, the team recommends that the site consider a new phased approach that combines additional characterization approaches and technologies to address the technical uncertainty in

  15. Holocene record of precipitation seasonality from lake calcite δ18O in the central Rocky Mountains, United States

    Science.gov (United States)

    Anderson, Lesleigh

    2011-01-01

    A context for recent hydroclimatic extremes and variability is provided by a ~10 k.y. sediment carbonate oxygen isotope (??18O) record at 5-100 yr resolution from Bison Lake, 3255 m above sea level, in northwestern Colorado (United States). Winter precipitation is the primary water source for the alpine headwater lake in the Upper Colorado River Basin and lake water ??18O measurements reflect seasonal variations in precipitation ??18O. Holocene lake water ??18O variations are inferred from endogenic sedimentary calcite ??18O based on comparisons with historic watershed discharge records and tree-ring reconstructions. Drought periods (i.e., drier winters and/or a more rain-dominated seasonal precipitation balance) generally correspond with higher calcite ??18O values, and vice-versa. Early to middle Holocene ??18O values are higher, implying a rain-dominated seasonal precipitation balance. Lower, more variable ??18O values after ca. 3500 yr ago indicate a snow-dominated but more seasonally variable precipitation balance. The middle to late Holocene ??18O record corresponds with records of El Ni??o Southern Oscillation intensification that supports a teleconnection between Rocky Mountain climate and North Pacific sea-surface temperatures at decade to century time scales. ?? 2011 Geological Society of America.

  16. Synthesis, photochromism and holographic optical recording of a novel diarylethene bearing a pyrrole unit

    Science.gov (United States)

    Liu, Gang; Liu, Ming; Pu, Shouzhi; Fan, Congbin

    2011-02-01

    A unsymmetrical photochromic diarylethene, 1-[2-methyl-5-(3-fluorophenyl)-3-thienyl]-2 -(2-cyano-1,5-dimethyl-4-pyrryl)hexafluorocyclopentene (1o), was synthesized. The photoconversion ratios from open-ring to closed-ring isomers at photostationary state under UV irradiation in hexane solution was measured by HPLC, and the properties, including photochromism and fluorescence properties were also investigated systematically. The results showed that this compound had good thermal stability and exhibited reversible photochromism, changing from colorless to blue after irradiation with UV light both in solution and in PMMA amorphous film. The open-ring isomer of the diarylethene 1 exhibited relatively strong fluorescence at 427 nm in hexane solution (5×10-5 mol/L) when excited at 340 nm. The fluorescence intensity decreased along with the photochromism upon irradiation with 297 nm light and its closed-ring isomer showed almost no fluorescence. Using diarylethene 1 as recording medium, polarization holographic optical recording was carried out successfully.

  17. Synthesis, photochromism and holographic optical recording of a novel diarylethene bearing a pyrrole unit

    Energy Technology Data Exchange (ETDEWEB)

    Liu Gang; Liu Ming; Pu Shouzhi; Fan Congbin, E-mail: pushouzhi@tsinghua.org.cn [Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang 330013 (China)

    2011-02-01

    A unsymmetrical photochromic diarylethene, 1-[2-methyl-5-(3-fluorophenyl)-3-thienyl]-2 -(2-cyano-1,5-dimethyl-4-pyrryl)hexafluorocyclopentene (1o), was synthesized. The photoconversion ratios from open-ring to closed-ring isomers at photostationary state under UV irradiation in hexane solution was measured by HPLC, and the properties, including photochromism and fluorescence properties were also investigated systematically. The results showed that this compound had good thermal stability and exhibited reversible photochromism, changing from colorless to blue after irradiation with UV light both in solution and in PMMA amorphous film. The open-ring isomer of the diarylethene 1 exhibited relatively strong fluorescence at 427 nm in hexane solution (5x10{sup -5} mol/L) when excited at 340 nm. The fluorescence intensity decreased along with the photochromism upon irradiation with 297 nm light and its closed-ring isomer showed almost no fluorescence. Using diarylethene 1 as recording medium, polarization holographic optical recording was carried out successfully.

  18. Development of a personal electronic health record card in the United Kingdom.

    Science.gov (United States)

    Rybynok, V O; Kyriacou, P A; Binnersley, J; Woodcock, A

    2010-01-01

    In most emergency situations, health professionals rely on patients to provide information about their medical history. However, in some cases patients might not be able to communicate this information, and in most countries, including the UK an on-line integrated patient record system has not been adopted. Therefore, in order to address this issue the ongoing project MyCare Card (MyC(2), www.myc2.org) has been established. The aim of this project is to design, implement and evaluate a prototype patient held electronic health record card. One of the tasks involved in the project was to develop a Graphical User Interface (GUI) software, which provides access to the data stored on the card. The requirements for this software had to be established via questionnaire surveys and end user evaluations, conducted simultaneously with the software development. This paper is addressing development of the MyCare Card GUI software. It also overviews the hardware and open-source software solutions selected for the MyCare Card implementation.

  19. Anatomy of biocalcarenitic units in the Plio-Pleistocene record of the Northern Apennines (Italy)

    Science.gov (United States)

    Cau, Simone; Roveri, Marco; Taviani, Marco

    2017-04-01

    The Castell'Arquato Basin (CAB) in the foothills of the thrust-belt Northern Apennines is a foreland basin infilled by Plio-Quaternary sediments and a reference area for Plio-Pleistocene biostratigraphy. The CAB exposes plurimetric biodetrital carbonate units at discrete temporal intervals. Such shell-rich units are at places lithified, turning into conspicuous biodetritral carbonate rocks (biocalcarenites) that display a cyclical stacking motif highlighted by the regular alternation with finer-grained marine deposits. The cyclical nature of thick biocalcarenites has been hypothesized to be orbitally-controlled by obliquity and/or precession cyclicity. Furthermore, biocalcarenite-mudstone couplets form distinct clusters governed by 100-400 ka eccentricity maxima starting from 3.1 Ma at the inception of the Northern Hemisphere glaciation. They correlate with sapropels cycles formed at times of maximum insolation (precession minima). The CAB calcarenites are poorly known with respect to their environmental genetic context what motivated a detailed paleoecological analysis to unravel at best their formative context. Five distinct biofacies arranged in stacking patterns are identified through two-way cluster analysis based on the macrofossil content. Our quantitative and qualitative results suggest that these polytaxic shell concentrations and their bracketing marine mudstones developed in middle shelf settings being sensitive to climatically-driven changes.

  20. Tectonometamorphic record in a fossilized subduction channel: insights from the Cycladic Blueschist Unit (Cyclades, Greece)

    Science.gov (United States)

    Laurent, Valentin; Roche, Vincent; Jolivet, Laurent; Lanari, Pierre; Augier, Romain; Scaillet, Stéphane

    2016-04-01

    The comprehension of subduction dynamics is partly based on the reconstruction of detailed Pressure-Temperature-time-deformation paths of HP-LT metamorphic rocks, which have undergone a complete burial-exhumation cycle. The Cycladic Blueschist Unit (CBU), located in the Aegean domain (Greece), is one of the best examples of a fossilized subduction channel. The tectonometamorphic history of this domain can be summarized in two successive episodes: (1) From the Paleocene to the Eocene, the formation of the Hellenides-Taurides belt due to the convergence between Eurasia and Africa. During this episode, the entrance of the Apulian crust in the subduction zone led to an episode of crustal thickening and formation-exhumation of HP-LT metamorphic units like the CBU. (2) From the Early Oligocene, consecutively to the retreat of the African slab, back-arc extension affected the previously thickened crust and the Aegean Sea started to form. Syros and Sifnos islands are worldwide known for their excellent preservation of HP-LT parageneses in the CBU, providing one of the best case-studies to understand the tectonometamorphic evolution of a subduction channel. This study aims to decipher the P-T-t-d path of the CBU using for the first time on Syros, Raman spectroscopy of carbonaceous material to constrain metamorphic peak temperature (Beyssac et al., 2002) and a quantitative X-ray micro-mapping approach together with the program XMapTools (Lanari et al., 2014). The micro-mapping tools allowed extracting local chemical compositions observed in zoned garnets to calculate the local effective bulk composition. Forward models are then created to constrain P-T conditions of crystallization of these local assemblages. This study brings new data on the debated metamorphic peak conditions of the CBU, which undoubtedly attained at least 20 ± 2 kbar / 530 ± 50°C. Additionally, the geological and metamorphic maps of Syros and Sifnos have been totally redrawn in order to decipher the

  1. Projected Numbers of Ischemic Strokes Recorded in the Austrian Stroke-Unit Registry from 2012 to 2075

    Science.gov (United States)

    Trinka, Eugen; Seyfang, Leonard; Mutzenbach, Sebastian; Stadler, Katharina; Pikija, Slaven; Killer, Monika; Broussalis, Erasmia

    2016-01-01

    Background and Purpose This study analyzed the number of patients with ischemic strokes recorded in the Austrian Stroke-Unit Registry with the aim of projecting this number from 2012 to 2075 and to highlight that the Austrian health system will face a dramatic increase in older patients within the next few decades. Methods Current demographic information was obtained from EUROSTAT, and information on age- and sex-stratified 1-year incidence rates of ischemic stroke were obtained from the Austrian Stroke-Unit Registry. Sensitivity analysis was performed by analyzing the projections based on predicted ageing, main, and growth population scenarios, and with stratification by age and gender. Results The total number of ischemic strokes recorded in the Austrian Stroke-Unit Registry was 8,690 in 2012 and is expected to increase to 15,826, 15,626, or 18,134 in 2075 according to the ageing, main, and growth scenarios, respectively. The corresponding numbers of patients are projected to increase or decrease within different age strata as follows (100%=number of registered ischemic strokes in 2012): 0–40 years, 100%/99% (males/females); 40–50 years, 83%/83%; 50–60 years, 98%/97%; 60–70 years, 126%/119%; 70–80 years, 159%/139%; 80–90 years, 307%/199%; and 90+ years, 894%/413%. Conclusions The ageing population in Austria will result in the number of patients increasing considerably from 2012 to 2075, to 182%, 180%, or 208% (relative to 100% in 2012) according to the ageing, main, and growth scenarios, respectively; the corresponding value among those aged 80+ years is 315%, 290%, or 347%. These figures demonstrated the importance of improving primary preventive measures. The results of this study should provide a basis for discussions among health-care professionals and economists to face the future large financial burden of ischemic stroke on the Austrian health system.

  2. Molten Salt Coal Gasification Process Development Unit. Phase 2. Quarterly technical progress report No. 2, October-December 1980

    Energy Technology Data Exchange (ETDEWEB)

    Slater, M. H.

    1981-01-20

    This represents the second quarterly progress report on Phase 2 of the Molten Salt Coal Gasification Process Development Unit (PDU) Program. Phase 1 of this program started in March 1976 and included the design, construction, and initial operation of the PDU. On June 25, 1980, Phase 2 of the program was initiated. It covers a 1-year operations program utilizing the existing PDU and is planned to include five runs with a targeted total operating time of 9 weeks. During this report period, Run 6, the initial run of the Phase 2 program was completed. The gasification system was operated for a total of 95 h at pressures up to 10 atm. Average product gas HHV values of 100 Btu/scf were recorded during 10-atm operation, while gasifying coal at a rate of 1100 lb/h. The run was terminated when the melt overflow system plugged after 60 continuous hours of overflow. Following this run, melt withdrawal system revisions were made, basically by changing the orifice materials from Monofrax to an 80 Cobalt-20 Chromium alloy. By the end of the report period, the PDU was being prepared for Run 7.

  3. Aquatic invertebrate sampling at selected outfalls in Operable Unit 1082; Technical areas 9, 11, 16 and 22

    Energy Technology Data Exchange (ETDEWEB)

    Cross, S.

    1995-09-01

    The Ecological Studies Team (EST) of ESH-20 at Los Alamos National Laboratory conducted preliminary aquatic sampling at outfalls within Operable Unit 1082 and nearby natural waterways. Eleven outfalls were sampled a total of eighteen times. Three natural waterways (upper Pajarito Canyon, Starmer`s Gulch, and Bulldog Spring) in the vicinity were sampled a total of six times. At most sites, EST recorded hydrological condition, physico-chemical parameters, wildlife uses, and vegetation. At each outfall with water and each natural waterway, EST collected an aquatic invertebrate sample which was analyzed by taxa composition, Wilhm`s biodiversity index, the community tolerance quotient (CTQ), and density. The physico-chemical parameters at most outfalls and natural waterways fell within the normal range of natural waters in the area. However, the outfalls are characterized by low biodiversity and severely stressed communities composed of a restricted number of taxa. The habitat at the other outfalls could probably support well-developed aquatic communities if sufficient water was available. At present, the hydrology at these outfalls is too slight and/or sporadic to support such a community in the foreseeable future. In contrast to the outfalls, the natural waterways of the area had greater densities of aquatic invertebrates, higher biodiversities, and lower CTQs.

  4. A 1300 Year Sub-Decadally Resolved Hydrologic Record from the Coastal Southwestern United States (Crystal Lake, CA)

    Science.gov (United States)

    Palermo, J. A.; Kirby, M. E.

    2015-12-01

    This study presents a 1300 year sub-decadally resolved record of hydrologic variability from coastal southwestern United States (Crystal Lake, CA). Crystal Lake is a small (0.02 km2), alpine landslide dammed lake in the Angeles National Forest of the San Gabriel Mountains. The hydrologically closed lake is the only permanent, freshwater lake in the range; its catchment is small (0.77 km2). In May 2014, lake depth measured 5.5 m, however the spillover point in the southeastern end of the lake indicates a max depth of ~50 m. Two Livingston piston cores were taken in May 2014, 15 m apart in the lake's depocenter. Magnetic susceptibility, LOI 550 °C and 950 °C, and grain size were measured at 1 cm contiguous intervals; C:N ratios and C and N isotopic analyses were measured every 2 cm. In addition, representative allochthonous and autochthonous vegetation were collected within the drainage basin for δ13Corg values. An age model was generated using Bacon v2.2, based on 11 AMS 14C dates of discrete organic matter (i.e. charcoal or wood). Age control for the past 200 years is based on correlation to Rothenberg et al. (2010) core ages. Initial results suggest a history of event sedimentation (large storms) superimposed on multi-decadal to centennial hydrologic changes (wet vs. dry periods) such as the Little Ice Age and the Medieval Climate Anomaly. Additionally, the Crystal Lake record is compared to preexisting regional records to further explore the record's spatial coherence. Mechanisms driving these hydrologic shifts are explored.

  5. Topping the 300-MW power unit at the GRES-24 district power station with a GTE-110 gas turbine unit. Technical solutions on the thermal circuit

    Science.gov (United States)

    Berezinets, P. A.; Tereshina, G. E.; Kryuchkova, T. I.

    2010-02-01

    We describe the outcomes from the development of a gas-turbine topping for the 300-MW power unit that was initially constructed as an attachment to an MHD-generator, which, however, has not been constructed. A 110-MW GTE-110 gas-turbine unit was used as a topping for this power unit. The topped power unit allows more than 9% of fuel to be saved as compared with the original one.

  6. United States of America activities relative to the International Atomic Energy Agency (IAEA) initiative: Records management for deep geologic repositories

    Energy Technology Data Exchange (ETDEWEB)

    Warner, P.J.

    1997-03-01

    The International Atomic Energy Agency (IAEA) has conducted consultant and advisory meetings to prepare a Technical Document which is intended to provide guidance to all IAEA Member States (otherwise known as countries) that are currently planning, designing, constructing or operating a deep or near surface geological repository for the storage and protection of vitrified high-level radioactive waste, spent fuel waste and TRU-waste (transuranic). Eleven countries of the international community are presently in various stages of siting, designing, or constructing deep geologic repositories. Member States of the IAEA have determined that the principle safety of such completed and operation sites must not rely solely on long term institutional arrangements for the retention of information. It is believed that repository siting, design, operation and postoperation information should be gathered, managed and retained in a manner that will provide information to future societies over a very long period of time. The radionuclide life is 10,000 years thus the retention of information must outlive current societies, languages, and be continually migrated to new technology to assure retrieval. This presentation will provide an overview of the status of consideration and implementation of these issues within the United States efforts relative to deep geologic repository projects.

  7. Babesiosis Occurrence among the Elderly in the United States, as Recorded in Large Medicare Databases during 2006–2013

    Science.gov (United States)

    Menis, Mikhail; Forshee, Richard A.; Kumar, Sanjai; McKean, Stephen; Warnock, Rob; Izurieta, Hector S.; Gondalia, Rahul; Johnson, Chris; Mintz, Paul D.; Walderhaug, Mark O.; Worrall, Christopher M.; Kelman, Jeffrey A.; Anderson, Steven A.

    2015-01-01

    Background Human babesiosis, caused by intraerythrocytic protozoan parasites, can be an asymptomatic or mild-to-severe disease that may be fatal. The study objective was to assess babesiosis occurrence among the U.S. elderly Medicare beneficiaries, ages 65 and older, during 2006–2013. Methods Our retrospective claims-based study utilized large Medicare administrative databases. Babesiosis occurrence was ascertained by recorded ICD-9-CM diagnosis code. The study assessed babesiosis occurrence rates (per 100,000 elderly Medicare beneficiaries) overall and by year, age, gender, race, state of residence, and diagnosis months. Results A total of 10,305 elderly Medicare beneficiaries had a recorded babesiosis diagnosis during the eight-year study period, for an overall rate of about 5 per 100,000 persons. Study results showed a significant increase in babesiosis occurrence over time (pBabesiosis occurrence was significantly higher among males vs. females and whites vs. non-whites. Conclusion Our study reveals increasing babesiosis occurrence among the U.S. elderly during 2006–2013, with highest rates in the babesiosis-endemic states. The study also shows variation in babesiosis occurrence by age, gender, race, state of residence, and diagnosis months. Overall, our study highlights the importance of large administrative databases in assessing the occurrence of emerging infections in the United States. PMID:26469785

  8. Babesiosis Occurrence among the Elderly in the United States, as Recorded in Large Medicare Databases during 2006-2013.

    Science.gov (United States)

    Menis, Mikhail; Forshee, Richard A; Kumar, Sanjai; McKean, Stephen; Warnock, Rob; Izurieta, Hector S; Gondalia, Rahul; Johnson, Chris; Mintz, Paul D; Walderhaug, Mark O; Worrall, Christopher M; Kelman, Jeffrey A; Anderson, Steven A

    2015-01-01

    Human babesiosis, caused by intraerythrocytic protozoan parasites, can be an asymptomatic or mild-to-severe disease that may be fatal. The study objective was to assess babesiosis occurrence among the U.S. elderly Medicare beneficiaries, ages 65 and older, during 2006-2013. Our retrospective claims-based study utilized large Medicare administrative databases. Babesiosis occurrence was ascertained by recorded ICD-9-CM diagnosis code. The study assessed babesiosis occurrence rates (per 100,000 elderly Medicare beneficiaries) overall and by year, age, gender, race, state of residence, and diagnosis months. A total of 10,305 elderly Medicare beneficiaries had a recorded babesiosis diagnosis during the eight-year study period, for an overall rate of about 5 per 100,000 persons. Study results showed a significant increase in babesiosis occurrence over time (pBabesiosis occurrence was significantly higher among males vs. females and whites vs. non-whites. Our study reveals increasing babesiosis occurrence among the U.S. elderly during 2006-2013, with highest rates in the babesiosis-endemic states. The study also shows variation in babesiosis occurrence by age, gender, race, state of residence, and diagnosis months. Overall, our study highlights the importance of large administrative databases in assessing the occurrence of emerging infections in the United States.

  9. Maps and grids of hydrogeologic information created from standardized water-well drillers’ records of the glaciated United States

    Science.gov (United States)

    Bayless, E. Randall; Arihood, Leslie D.; Reeves, Howard W.; Sperl, Benjamin J.S.; Qi, Sharon L.; Stipe, Valerie E.; Bunch, Aubrey R.

    2017-01-18

    As part of the National Water Availability and Use Program established by the U.S. Geological Survey (USGS) in 2005, this study took advantage of about 14 million records from State-managed collections of water-well drillers’ records and created a database of hydrogeologic properties for the glaciated United States. The water-well drillers’ records were standardized to be relatively complete and error-free and to provide consistent variables and naming conventions that span all State boundaries.Maps and geospatial grids were developed for (1) total thickness of glacial deposits, (2) total thickness of coarse-grained deposits, (3) specific-capacity based transmissivity and hydraulic conductivity, and (4) texture-based estimated equivalent horizontal and vertical hydraulic conductivity and transmissivity. The information included in these maps and grids is required for most assessments of groundwater availability, in addition to having applications to studies of groundwater flow and transport. The texture-based estimated equivalent horizontal and vertical hydraulic conductivity and transmissivity were based on an assumed range of hydraulic conductivity values for coarse- and fine-grained deposits and should only be used with complete awareness of the methods used to create them. However, the maps and grids of texture-based estimated equivalent hydraulic conductivity and transmissivity may be useful for application to areas where a range of measured values is available for re-scaling.Maps of hydrogeologic information for some States are presented as examples in this report but maps and grids for all States are available electronically at the project Web site (USGS Glacial Aquifer System Groundwater Availability Study, http://mi.water.usgs.gov/projects/WaterSmart/Map-SIR2015-5105.html) and the Science Base Web site, https://www.sciencebase.gov/catalog/item/58756c7ee4b0a829a3276352.

  10. Evaluation of medication errors with implementation of electronic health record technology in the medical intensive care unit

    Directory of Open Access Journals (Sweden)

    Liao TV

    2017-05-01

    Full Text Available T Vivian Liao,1 Marina Rabinovich,2 Prasad Abraham,2 Sebastian Perez,3 Christiana DiPlotti,4 Jenny E Han,5 Greg S Martin,5 Eric Honig5 1Department of Pharmacy Practice, College of Pharmacy, Mercer Health Sciences Center, 2Department of Pharmacy and Clinical Nutrition, Grady Health System, 3Department of Surgery, Emory University, 4Pharmacy, Ingles Markets, 5Department of Medicine, Emory University, Atlanta, GA, USA Purpose: Patients in the intensive care unit (ICU are at an increased risk for medication errors (MEs and adverse drug events from multifactorial causes. ME rate ranges from 1.2 to 947 per 1,000 patient days in the medical ICU (MICU. Studies with the implementation of electronic health records (EHR have concluded that it significantly reduced overall prescribing errors and the number of errors that caused patient harm decreased. However, other types of errors, such as wrong dose and omission of required medications increased after EHR implementation. We sought to compare the number of MEs before and after EHR implementation in the MICU, with additional evaluation of error severity.Patients and methods: Prospective, observational, quality improvement study of all patients admitted to a single MICU service at an academic medical center. Patients were evaluated during four periods over 2 years: August–September 2010 (preimplementation; period I, January–February 2011 (2 months postimplementation; period II, August–September 2012 (21 months postimplementation; period III, and January–February 2013 (25 months postimplementation; period IV. All medication orders and administration records were reviewed by an ICU clinical pharmacist and ME was defined as a deviation from established standards for prescribing, dispensing, administering, or documenting medication. The frequency and classification of MEs were compared between groups by chi square; p<0.05 was considered significant.Results: There was a statistically significant increase

  11. A socio-technical approach for the design of a production control system : towards controllable production units

    NARCIS (Netherlands)

    Slomp, Jannes; Ruël, Gwenny C.

    2000-01-01

    In the design of a production control system much attention is usually paid to technicalaspects, whereas the elaboration upon social aspects remain underexposed. SociotechnicalSystems Theory (SST) emphasizes the importance of finding a joint optimization between the technical and the social systems

  12. Managing a Basic Unit Responsible for a Basic Discipline: The Physics Department at the Technical University, Aachen.

    Science.gov (United States)

    Felderhof, B. U.

    1983-01-01

    The administrative structure of the physics department in a major European technical university is described, particularly with regard to the organization of teaching and research functions. The department is subdivided into an institute of theoretical physics and several institutes of experimental physics, with a more important subdivision into…

  13. A Review of the Availability of Primary Scientific and Technical Documents within the United States, Volume I. Final Report.

    Science.gov (United States)

    Wood, James L.

    Volume I of this three-volume final report contains a summary of the objectives and results of a study conducted by Chemical Abstracts Service (CAS), a Division of the American Chemical Society (ACS), to determine the availability of the scientific and technical primary literature which the user identifies through the use of secondary services…

  14. Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach Nuclear Power Plant, Units 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Laudenbach, D.H.

    1979-03-01

    The technical evaluation is presented for the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach nuclear power plant, Units 1 and 2. Design basis criteria used to evaluate the acceptability of the system included operator action, system testability, single failure criterion, and seismic Category I and IEEE Std-279-1971 criteria. This report is supplied as part of the Selected Electrical, Instrumentation, and Control Systems Issues Support Program being conducted for the U.S. Nuclear Regulatory Commission by Lawrence Livermore Laboratory.

  15. Using the diffusion of innovations theory to assess socio-technical factors in planning the implementation of an electronic health record alert across multiple primary care clinics.

    Science.gov (United States)

    Lin, Ching-Pin; Guirguis-Blake, Janelle; Keppel, Gina A; Dobie, Sharon; Osborn, Justin; Cole, Allison M; Baldwin, Laura-Mae

    2016-04-15

    Adverse drug events (ADEs) are a leading cause of death in the United States. Patients with stage 3 and 4 chronic kidney disease (CKD) are at particular risk because many medications are cleared by the kidneys. Alerts in the electronic health record (EHR) about drug appropriateness and dosing at the time of prescription have been shown to reduce ADEs for patients with stage 3 and 4 CKD in inpatient settings, but more research is needed about the implementation and effectiveness of such alerts in outpatient settings.  To explore factors that might inform the implementation of an electronic drug-disease alert for patients with CKD in primary care clinics, using Rogers' diffusion of innovations theory as an analytic framework. Interviews were conducted with key informants in four diverse clinics using various EHR systems. Interviews were audio recorded and transcribed. results Although all clinics had a current method for calculating glomerular filtration rate (GFR), clinics were heterogeneous with regard to current electronic decision support practices, quality improvement resources, and organizational culture and structure. Understanding variation in organizational culture and infrastructure across primary care clinics is important in planning implementation of an intervention to reduce ADEs among patients with CKD.

  16. Technical challenges related to implementation of a formula one real time data acquisition and analysis system in a paediatric intensive care unit.

    Science.gov (United States)

    Matam, B Rajeswari; Duncan, Heather

    2017-07-27

    Most existing, expert monitoring systems do not provide the real time continuous analysis of the monitored physiological data that is necessary to detect transient or combined vital sign indicators nor do they provide long term storage of the data for retrospective analyses. In this paper we examine the feasibility of implementing a long term data storage system which has the ability to incorporate real-time data analytics, the system design, report the main technical issues encountered, the solutions implemented and the statistics of the data recorded. McLaren Electronic Systems expertise used to continually monitor and analyse the data from F1 racing cars in real time was utilised to implement a similar real-time data recording platform system adapted with real time analytics to suit the requirements of the intensive care environment. We encountered many technical (hardware and software) implementation challenges. However there were many advantages of the system once it was operational. They include: (1) The ability to store the data for long periods of time enabling access to historical physiological data. (2) The ability to alter the time axis to contract or expand periods of interest. (3) The ability to store and review ECG morphology retrospectively. (4) Detailed post event (cardiac/respiratory arrest or other clinically significant deteriorations in patients) data can be reviewed clinically as opposed to trend data providing valuable clinical insight. Informed mortality and morbidity reviews can be conducted. (5) Storage of waveform data capture to use for algorithm development for adaptive early warning systems. Recording data from bed-side monitors in intensive care/wards is feasible. It is possible to set up real time data recording and long term storage systems. These systems in future can be improved with additional patient specific metrics which predict the status of a patient thus paving the way for real time predictive monitoring.

  17. AES-2006 NPPs with VVER-1200 UNITs as a new approach to display of information from technical diagnosis systems

    Directory of Open Access Journals (Sweden)

    Yu.A. Baranova

    2015-09-01

    Full Text Available Operator performance in the main control room (MCR depends to a great extent on the form and amount of the information on the nuclear plant process status. An unstructured form of data display may result in an increase in the data processing time and in errors in the decisions made by operators. Convenience of the NPP data flow handling is given an increased focus but the process of supplying diagnostic data to operating personnel is neglected by both the developers of technical diagnosis systems and by the MCR interface designers. The paper provides an analysis of the upper-level information from technical diagnosis systems and presents requirements to respective screen forms and implementation options.

  18. Coccidian parasites (Apicomplexa) from snakes in the southcentral and southwestern United States: new host and geographic records.

    Science.gov (United States)

    McAllister, C T; Upton, S J; Trauth, S E; Dixon, J R

    1995-02-01

    Four hundred thirty-five leptotyphlopid, colubrid, elapid, and viperid snakes were collected from various localities in Arkansas, New Mexico, Oklahoma, and Texas, and their feces were examined for coccidian parasites. Of these, 131 (30%) were passing oocysts or sporocysts of at least 1 coccidian; 88 (67%) of the infected snakes had only 1 species of coccidian when they were examined. Aquatic and semiaquatic snakes accounted for 48% of the infections, whereas strictly terrestrial snakes comprised the other 52%. There was more than a 2-fold difference in prevalence among these 2 groups as 63 of 129 (49%) of the aquatic and semiaquatic snakes versus 68 of 306 (22%) of the terrestrial snakes harbored coccidia. Most terrestrial snakes were infected by species of Caryospora and Sarcocystis that are either facultatively or obligatorily heteroxenous. The aquatic and semiaquatic species most often harbored eimerians. Attempts to transmit some of the Sarcocystis spp. experimentally from Crotalus atrox to Mus musculus, Peromyscus leucopus, Peromyscus maniculatus, or Microtus ochrogaster were unsuccessful. This report documents 27 new host and several distributional records for coccidians from snakes in the southcentral and southwestern United States.

  19. End of FY10 report - used fuel disposition technical bases and lessons learned : legal and regulatory framework for high-level waste disposition in the United States.

    Energy Technology Data Exchange (ETDEWEB)

    Weiner, Ruth F.; Blink, James A. (Lawrence Livermore National Laboratory, Livermore, CA); Rechard, Robert Paul; Perry, Frank (Los Alamos National Laboratory, Los Alamos, NM); Jenkins-Smith, Hank C. (University of Oklahoma, Norman, OK); Carter, Joe (Savannah River Nuclear Solutions, Aiken, SC); Nutt, Mark (Argonne National Laboratory, Argonne, IL); Cotton, Tom (Complex Systems Group, Washington DC)

    2010-09-01

    This report examines the current policy, legal, and regulatory framework pertaining to used nuclear fuel and high level waste management in the United States. The goal is to identify potential changes that if made could add flexibility and possibly improve the chances of successfully implementing technical aspects of a nuclear waste policy. Experience suggests that the regulatory framework should be established prior to initiating future repository development. Concerning specifics of the regulatory framework, reasonable expectation as the standard of proof was successfully implemented and could be retained in the future; yet, the current classification system for radioactive waste, including hazardous constituents, warrants reexamination. Whether or not consideration of multiple sites are considered simultaneously in the future, inclusion of mechanisms such as deliberate use of performance assessment to manage site characterization would be wise. Because of experience gained here and abroad, diversity of geologic media is not particularly necessary as a criterion in site selection guidelines for multiple sites. Stepwise development of the repository program that includes flexibility also warrants serious consideration. Furthermore, integration of the waste management system from storage, transportation, and disposition, should be examined and would be facilitated by integration of the legal and regulatory framework. Finally, in order to enhance acceptability of future repository development, the national policy should be cognizant of those policy and technical attributes that enhance initial acceptance, and those policy and technical attributes that maintain and broaden credibility.

  20. Design, construction, operation and evaluation of a prototype culm combustion boiler/heater unit. Technical progress report, October 1-December 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1980-02-01

    This report provides a summary of the work performed on the Prototype Culm Combustion Boiler/Heater Unit, Phase I - Engineering Design and Analysis and Limited Phase II - Prototype Plant Construction during the period October 1, 1979 through December 31, 1979. The objectives of the program as well as the technical progress and problem areas encountered are presented. Progress on the components and system engineering studies is described. The Preliminary Design of Prototype Unit Topical Report was submitted. Final design activity is continuing and the progress on drawing preparation and advanced procurement activity is discussed. Based on authorization for a limited amount of Phase II activity, initial Purchase Orders were released authorizing preparation of certified drawings for fabricated equipment required to support the Phase I final design activity. The Purchase Order for site clearance and installation of boiler foundations was awarded and ground breaking ceremonies were held at the Prototype Culm Combustion Boiler site in Paxinos, Pennsylvania, on December 7, 1979.

  1. AES-2006 NPPs with VVER-1200 UNITs as a new approach to display of information from technical diagnosis systems

    OpenAIRE

    Yu.A. Baranova; Slepov, M.T.

    2015-01-01

    Operator performance in the main control room (MCR) depends to a great extent on the form and amount of the information on the nuclear plant process status. An unstructured form of data display may result in an increase in the data processing time and in errors in the decisions made by operators. Convenience of the NPP data flow handling is given an increased focus but the process of supplying diagnostic data to operating personnel is neglected by both the developers of technical diagnosis sy...

  2. Understanding barriers and facilitators to the use of Clinical Information Systems for intensive care units and Anesthesia Record Keeping: A rapid ethnography.

    Science.gov (United States)

    Saleem, Jason J; Plew, William R; Speir, Ross C; Herout, Jennifer; Wilck, Nancy R; Ryan, Dale Marie; Cullen, Theresa A; Scott, Jean M; Beene, Murielle S; Phillips, Toni

    2015-07-01

    This study evaluated the current use of commercial-off-the-shelf Clinical Information Systems (CIS) for intensive care units (ICUs) and Anesthesia Record Keeping (ARK) for operating rooms and post-anesthesia care recovery settings at three Veterans Affairs Medical Centers (VAMCs). Clinicians and administrative staff use these applications at bedside workstations, in operating rooms, at nursing stations, in physician's rooms, and in other various settings. The intention of a CIS or an ARK system is to facilitate creation of electronic records of data, assessments, and procedures from multiple medical devices. The US Department of Veterans Affairs (VA) Office of the Chief of Nursing Informatics sought to understand usage barriers and facilitators to optimize these systems in the future. Therefore, a human factors study was carried out to observe the CIS and ARK systems in use at three VAMCs in order to identify best practices and suggested improvements to currently implemented CIS and ARK systems. We conducted a rapid ethnographic study of clinical end-users interacting with the CIS and ARK systems in the critical care and anesthesia care areas in each of three geographically distributed VAMCs. Two observers recorded interactions and/or interview responses from 88 CIS and ARK end-users. We coded and sorted into logical categories field notes from 69 shadowed participants. The team transcribed and combined data from key informant interviews with 19 additional participants with the observation data. We then integrated findings across observations into meaningful patterns and abstracted the data into themes, which translated directly to barriers to effective adoption and optimization of the CIS and ARK systems. Effective optimization of the CIS and ARK systems was impeded by: (1) integration issues with other software systems; (2) poor usability; (3) software challenges; (4) hardware challenges; (5) training concerns; (6) unclear roles and lack of coordination among

  3. Unit-specific calibration of Actigraph accelerometers in a mechanical setup - is it worth the effort? The effect on random output variation caused by technical inter-instrument variability in the laboratory and in the field

    DEFF Research Database (Denmark)

    Moeller, Niels C; Korsholm, Lars; Kristensen, Peter L

    2008-01-01

    during free living conditions. RESULTS: Calibration reduced inter-instrument variability considerably in the mechanical setup, both in the MTI instruments (raw SDbetween units = 195 counts*min-1 vs. calibrated SDbetween units = 65 counts*min-1) and in the CSA instruments (raw SDbetween units = 343 counts...... conditions had no apparent effect on inter-instrument variability. In all probability, the effect of technical calibration was primarily attenuated in the field by other more dominant sources of variation. However, routine technical assessments are still very important for determining the acceleration...

  4. Development of a large urban longitudinal HIV clinical cohort using a web-based platform to merge electronically and manually abstracted data from disparate medical record systems: technical challenges and innovative solutions.

    Science.gov (United States)

    Greenberg, Alan E; Hays, Harlen; Castel, Amanda D; Subramanian, Thilakavathy; Happ, Lindsey Powers; Jaurretche, Maria; Binkley, Jeff; Kalmin, Mariah M; Wood, Kathy; Hart, Rachel

    2016-05-01

    Electronic medical records (EMRs) are being increasingly utilized to conduct clinical and epidemiologic research in numerous fields. To monitor and improve care of HIV-infected patients in Washington, DC, one of the most severely affected urban areas in the United States, we developed a city-wide database across 13 clinical sites using electronic data abstraction and manual data entry from EMRs. To develop this unique longitudinal cohort, a web-based electronic data capture system (Discovere®) was used. An Agile software development methodology was implemented across multiple EMR platforms. Clinical informatics staff worked with information technology specialists from each site to abstract data electronically from each respective site's EMR through an extract, transform, and load process. Since enrollment began in 2011, more than 7000 patients have been enrolled, with longitudinal clinical data available on all patients. Data sets are produced for scientific analyses on a quarterly basis, and benchmarking reports are generated semi-annually enabling each site to compare their participants' clinical status, treatments, and outcomes to the aggregated summaries from all other sites. Numerous technical challenges were identified and innovative solutions developed to ensure the successful implementation of the DC Cohort. Central to the success of this project was the broad collaboration established between government, academia, clinics, community, information technology staff, and the patients themselves. Our experiences may have practical implications for researchers who seek to merge data from diverse clinical databases, and are applicable to the study of health-related issues beyond HIV. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. NOAA Climate Data Record of Microwave Sounding Unit (MSU) and Advanced Microwave Sounding Unit (AMSU-A) Mean Layer Temperature, Version 3.0

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The dataset contains three channel-based, monthly gridded atmospheric layer temperature Climate Data Records generated by merging nine MSU NOAA polar orbiting...

  6. District space heating potential of low temperature hydrothermal geothermal resources in the southwestern United States. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    McDevitt, P.K.; Rao, C.R.

    1978-10-01

    A computer simulation model (GIRORA-Nonelectric) is developed to study the economics of district space heating using geothermal energy. GIRORA-Nonelectric is a discounted cashflow investment model which evaluates the financial return on investment for space heating. This model consists of two major submodels: the exploration for and development of a geothermal anomaly by a geothermal producer, and the purchase of geothermal fluid by a district heating unit. The primary output of the model is a calculated rate of return on investment earned by the geothermal producer. The results of the sensitivity analysis of the model subject to changes in physical and economic parameters are given in this report. Using the results of the economic analysis and technological screening criteria, all the low temperature geothermal sites in Southwestern United States are examined for economic viability for space heating application. The methodology adopted and the results are given.

  7. Design, construction, operation, and evaluation of a prototype culm-combustion boiler/heater unit. Quarterly technical progress report, October 1-December 31, 1980

    Energy Technology Data Exchange (ETDEWEB)

    1981-02-01

    This report provides a summary of the work performed on the Prototype Culm Combustion Boiler/Heater Unit, Phase I - Engineering Design and Analysis and Phase II - Prototype Plant Construction during the period October 1, 1980 through December 31, 1980. The objectives of the program as well as the technical progress and problem areas encountered during the reporting period are presented. The final detail design effort was completed and the final design report submitted. Progress on procurement activity authorized by full Phase II release on March 20, 1980, is discussed. Following approval by DOE, a purchase order was placed with the Norflor Construction Corporation for the prototype plant construction which began in November. Construction of the access roadway installation of the electric power, sewer and water lines was completed during this reporting period. Boiler construction continued.

  8. Influence of technical processing units on chemical composition and antimicrobial activity of carrot (Daucus carrot L.) juice essential oil.

    Science.gov (United States)

    Ma, Tingting; Luo, Jiyang; Tian, Chengrui; Sun, Xiangyu; Quan, Meiping; Zheng, Cuiping; Kang, Lina; Zhan, Jicheng

    2015-03-01

    The effect of three processing units (blanching, enzyme liquefaction, pasteurisation) on chemical composition and antimicrobial activity of carrot juice essential oil was investigated in this paper. A total of 36 compounds were identified by GC-MS from fresh carrot juice essential oil. The main constituents were carotol (20.20%), sabinene (12.80%), β-caryophyllene (8.04%) and α-pinene (6.05%). Compared with the oil of fresh juice, blanching and pasteurisation could significantly decrease the components of the juice essential oil, whereas enzyme liquefaction had no considerable effect on the composition of juice essential oil. With regard to the antimicrobial activity, carrot juice essential oil could cause physical damage and morphological alteration on microorganisms, while the three different processing units showed noticeable differences on the species of microorganisms, the minimum inhibitory concentration and minimum bactericidal concentration. Results revealed that the carrot juice essential oil has great potential for application as a natural antimicrobial applied in pharmaceutical and food industries.

  9. Confidentiality of the medical records of HIV-positive patients in the United Kingdom – a medicolegal and ethical perspective

    Directory of Open Access Journals (Sweden)

    Mike Williams

    2011-01-01

    Full Text Available Mike WilliamsHead of Service, Cambridge University Dental Service, Cambridge, UKAbstract: This article examines the legal and ethical issues that surround the confidentiality of medical records, particularly in relation to patients who are HIV positive. It records some historical background of the HIV epidemic, and considers the relative risks of transmission of HIV from individual to individual. It explains the law as it pertains to confidentiality, and reports the professional guidance in these matters. It then considers how these relate to HIV-positive individuals in particular.Keywords: HIV/AIDS, confidentiality, medical records

  10. High-density surface EMG decomposition allows for recording of motor unit discharge from proximal and distal flexion synergy muscles simultaneously in individuals with stroke.

    Science.gov (United States)

    Miller, Laura C; Thompson, Christopher K; Negro, Francesco; Heckman, C J; Farina, Dario; Dewald, Julius P A

    2014-01-01

    Analysis of motor unit discharge can provide insight into the neural control of movement in healthy and pathological states, but it is typically completed in one muscle at a time. For some research investigations, it would be advantageous to study motor unit discharge from multiple muscles simultaneously. One such example is investigation of the flexion synergy, an abnormal muscle co-activation pattern in post-stroke individuals in which activation of shoulder abductors is involuntarily coupled with that of elbow and finger flexors. However, limitations in available technology have hindered the ability to efficiently extract motor unit discharge from multiple muscles simultaneously. In this study, we propose the use of high-density surface EMG decomposition from proximal and distal flexion synergy muscles (deltoid, biceps, wrist/finger flexors) in combination with an isometric joint torque recording device in individuals with chronic stroke. This innovative approach provides the ability to efficiently analyze both motor units and joint torques that have been simultaneously recorded from the shoulder, elbow, and fingers. In preliminary experiments, 3 stroke and 5 control participants generated shoulder abduction, elbow flexion, and finger flexion torques at 10, 20, 30 and 40% of maximum torque. Motor unit spike trains could be extracted from all muscles at each torque level. Mean motor unit firing rates were significantly lower in the stroke group than in the control group for all three muscles. Within the stroke group, wrist/finger flexor motor units had the lowest coefficient of variation. Additionally, modulation of mean firing rates across torque levels was significantly impaired in all three paretic muscles. The implications of these findings and overall impact of this approach are discussed.

  11. Design, construction, operation and evaluation of a Prototype Culm Combustion Boiler/Heater Unit. Quarterly technical progress report, October 1-December 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1980-02-01

    This report provides a summary of the work performed on the Prototype Culm Combustion Boiler/Heater Unit, Phase I - Engineering Design and Analysis and Limited Phase II - Prototype Plant Construction during the period October 1, 1979 through December 31, 1979. The objectives of the program as well as the technical progress and problem areas encountered during the reporting period are presented. Progress on the components and system engineering studies is described. The Preliminary Design of Prototype Unit Topical Report was submitted during this reporting period. Final design activity is continuing and the progress on drawing preparation and advanced procurement activity is discussed. Based on authorization for a limited amount of Phase II activity, initial purchase orders were released authorizing preparation of certified drawings for fabricated equipment required to support the Phase I final design activity. The Purchase Order for site clearance and installation of boiler foundations was awarded during this reporting period and ground breaking ceremonies were held at the Prototype Culm Combustion Boiler site in Paxinos, Pennsylvania on December 7, 1979.

  12. [Medical and technical means for united circle of evacuation measures in military-medical organisations of the Ministry of Defence].

    Science.gov (United States)

    Fisun, A Ya; Kalachev, O V; Shchegolev, A V; Vertii, B D

    2015-06-01

    Experts of the medical service of the Armed Forces carried out an analysis of capabilities of modern Russian enterprises and their innovative projects regarding creation of unified means of evacuation of wounded and providing to them necessary types of emergency care with the use of existing and future special and regular means of transport for medical evacuation. As a result of the work of industrial enterprises of the OAO Kazan "Vertoletniy Zavod", "Zarechie", "Vysota" was created a device for the medical evacuation of severe wounded patients. The device is designed for medical evacuation of severe wounded patients from the military medical unit to the site providing comprehensive medical care with maintenance of vital functions and monitoring of his condition. Testing was conducted on the products of regular vehicles medical company of one of the brigades of the Western Military District. The device was presented at the special tactical exercises the Armed Forces Medical Service "Frontier-2014", "Innovation Day" of the Defence Ministry in 2014.

  13. The Strategy Analysis of the United States Dealing with Technical Trade Barriers%美国应对贸易的技术壁垒战略分析

    Institute of Scientific and Technical Information of China (English)

    唐良富; 张锐; 解如风; 朱洪艳; 张旻旻; 王郡; 唐榆凯

    2012-01-01

    Through the analysis of Title 19, Customs Duties of TRADE AGREEMENTS ACT OF 1979, especially the tech-nical trade barriers ( standard) , we can see the American law preferred international trade law, standardization activities and international standards'adoption, the American foreign commercial protection, basic term definition, reasonable meas-ures of the president, functions of the federal government agencies, responsibilities and requirements of standard informa-tion center, etc. Through all kinds of policies of the United States since the financial crisis, we can see the "attack and prevention" , the new strategic development of Obama administration dealing with technical trade barriers.%通过分析《美国海关法典》中的《1979年贸易协定法》,特别是其中的《贸易的技术壁垒(标准)》,可看到美国的美国法优先国际贸易法、标准化活动及采用国际标准、对美国对外商业保护、基本术语定义、总统应采取合理的措施、联邦政府机构的职能,标准信息中心职责和要求等情况.通过金融危机以来美国种种举措,可以看到奥巴马政府应对贸易的技术壁垒的“攻与防”战略新发展.

  14. pHEMA encapsulated PEDOT-PSS-CNT microsphere microelectrodes for recording single unit activity in the brain

    Directory of Open Access Journals (Sweden)

    Elisa eCastagnola

    2016-04-01

    Full Text Available The long-term reliability of neural interfaces and stability of high-quality recordings are still unsolved issues in neuroscience research. High surface area PEDOT-PSS-CNT composites are able to greatly improve the performance of recording and stimulation for traditional intracortical metal microelectrodes by decreasing their impedance and increasing their charge transfer capability. This enhancement significantly reduces the size of the implantable device though preserving excellent electrical performances. On the other hand, the presence of nanomaterials often rises concerns regarding possible health hazards, especially when considering a clinical application of the devices. For this reason, we decided to explore the problem from a new perspective by designing and testing an innovative device based on nanostructured microspheres grown on a thin tether, integrating PEDOT-PSS-CNT nanocomposites with a soft synthetic permanent biocompatible hydrogel. The pHEMA hydrogel preserves the electrochemical performance and high quality recording ability of PEDOT-PSS-CNT coated devices, reduces the mechanical mismatch between soft brain tissue and stiff devices and also avoids direct contact between the neural tissue and the nanocomposite, by acting as a biocompatible protective barrier against potential nanomaterial detachment. Moreover, the spherical shape of the electrode together with the surface area increase provided by the nanocomposite deposited on it, maximize the electrical contact and may improve recording stability over time. These results have a good potential to contribute to fulfill the grand challenge of obtaining stable neural interfaces for long-term applications.

  15. Methods for implantation of micro-wire bundles and optimization of single/multi-unit recordings from human mesial temporal lobe

    Science.gov (United States)

    Misra, A.; Burke, J. F.; Ramayya, A. G.; Jacobs, J.; Sperling, M. R.; Moxon, K. A.; Kahana, M. J.; Evans, J. J.; Sharan, A. D.

    2014-04-01

    Objective. The authors report methods developed for the implantation of micro-wire bundles into mesial temporal lobe structures and subsequent single neuron recording in epileptic patients undergoing in-patient diagnostic monitoring. This is done with the intention of lowering the perceived barriers to routine single neuron recording from deep brain structures in the clinical setting. Approach. Over a 15 month period, 11 patients were implanted with platinum micro-wire bundles into mesial temporal structures. Protocols were developed for (A) monitoring electrode integrity through impedance testing, (B) ensuring continuous 24-7 recording, (C) localizing micro-wire position and ‘splay’ pattern and (D) monitoring grounding and referencing to maintain the quality of recordings. Main results. Five common modes of failure were identified: (1) broken micro-wires from acute tensile force, (2) broken micro-wires from cyclic fatigue at stress points, (3) poor in vivo micro-electrode separation, (4) motion artifact and (5) deteriorating ground connection and subsequent drop in common mode noise rejection. Single neurons have been observed up to 14 days post-implantation and on 40% of micro-wires. Significance. Long-term success requires detailed review of each implant by both the clinical and research teams to identify failure modes, and appropriate refinement of techniques while moving forward. This approach leads to reliable unit recordings without prolonging operative times, which will help increase the availability and clinical viability of human single neuron data.

  16. The record of major quaternary sea-level changes in a large coastal plain estuary, Chesapeake Bay, Eastern United States

    Science.gov (United States)

    Colman, Steven M.; Mixon, R.B.

    1988-01-01

    Seismic-reflection surveys of the Chesapeake Bay, combined with geologic mapping and analysis of boreholes on the Delmarva Peninsula, provide evidence of at least three generations of the Susquehanna River system and three generations of the Chesapeake Bay. The evidence for ancient courses of the Susquehanna River is preserved as three distinct paleochannels, and evidence for ancient versions of the Chesapeake Bay is preserved as three sets of paleochannel fill beneath the bay and three generations of barrier-spit deposits on the southern Delmarva Peninsula. The paleochannels represent relative sea-level minima and the channel-fill and barrier-spit deposits represents relative sea-level maxima. A history of three major marine transgressions is recorded in the stratigraphy preserved in the filled paleochannels and in the overlying barrier-spit complexes: three systematic progressions from fluvial to estuarine to bay or nearshore marine environments. This sea-level record seems to be compatible with the saw-toothed pattern of the marine oxygen-isotope record and with the concept of glacial-interglacial terminations. It also seems to have a climax character in which most of the preserved evidence is related to the largest terminations and to the extreme sea-level positions that bound those terminations. The three paleochannel-fill and barrier-spit complexes appear to correspond to oxygen-isotope stages 1,5, and either 7 or 11; the three related paleochannels correspond to stages 2, 6, and either 8 or 12. ?? 1988.

  17. Technical implementation plan for the ShakeAlert production system: an Earthquake Early Warning system for the West Coast of the United States

    Science.gov (United States)

    Given, Douglas D.; Cochran, Elizabeth S.; Heaton, Thomas; Hauksson, Egill; Allen, Richard; Hellweg, Peggy; Vidale, John; Bodin, Paul

    2014-01-01

    Earthquake Early Warning (EEW) systems can provide as much as tens of seconds of warning to people and automated systems before strong shaking arrives. The United States Geological Survey (USGS) and its partners are developing such an EEW system, called ShakeAlert, for the West Coast of the United States. This document describes the technical implementation of that system, which leverages existing stations and infrastructure of the Advanced National Seismic System (ANSS) regional networks to achieve this new capability. While significant progress has been made in developing the ShakeAlert early warning system, improved robustness of each component of the system and additional testing and certification are needed for the system to be reliable enough to issue public alerts. Major components of the system include dense networks of ground motion sensors, telecommunications from those sensors to central processing systems, algorithms for event detection and alert creation, and distribution systems to alert users. Capital investment costs for a West Coast EEW system are projected to be $38.3M, with additional annual maintenance and operations totaling $16.1M—in addition to current ANSS expenditures for earthquake monitoring. An EEW system is complementary to, but does not replace, other strategies to mitigate earthquake losses. The system has limitations: false and missed alerts are possible, and the area very near to an earthquake epicenter may receive little or no warning. However, such an EEW system would save lives, reduce injuries and damage, and improve community resilience by reducing longer-term economic losses for both public and private entities.

  18. Technical implementation plan for the ShakeAlert production system: an Earthquake Early Warning system for the West Coast of the United States

    Science.gov (United States)

    Given, Douglas D.; Cochran, Elizabeth S.; Heaton, Thomas; Hauksson, Egill; Allen, Richard; Hellweg, Peggy; Vidale, John; Bodin, Paul

    2014-01-01

    Earthquake Early Warning (EEW) systems can provide as much as tens of seconds of warning to people and automated systems before strong shaking arrives. The United States Geological Survey (USGS) and its partners are developing such an EEW system, called ShakeAlert, for the West Coast of the United States. This document describes the technical implementation of that system, which leverages existing stations and infrastructure of the Advanced National Seismic System (ANSS) regional networks to achieve this new capability. While significant progress has been made in developing the ShakeAlert early warning system, improved robustness of each component of the system and additional testing and certification are needed for the system to be reliable enough to issue public alerts. Major components of the system include dense networks of ground motion sensors, telecommunications from those sensors to central processing systems, algorithms for event detection and alert creation, and distribution systems to alert users. Capital investment costs for a West Coast EEW system are projected to be $38.3M, with additional annual maintenance and operations totaling $16.1M—in addition to current ANSS expenditures for earthquake monitoring. An EEW system is complementary to, but does not replace, other strategies to mitigate earthquake losses. The system has limitations: false and missed alerts are possible, and the area very near to an earthquake epicenter may receive little or no warning. However, such an EEW system would save lives, reduce injuries and damage, and improve community resilience by reducing longer-term economic losses for both public and private entities.

  19. NASA/DOD Aerospace Knowledge Diffusion Research Project. Paper 61: The Technical Communications Practices of ESL Aerospace Engineering Students in the United States: Results of a National Survey

    Science.gov (United States)

    Webb, John R.; Pinelli, Thomas E.; Barclay, Rebecca O.; Kennedy, John M.

    1997-01-01

    When engineering students graduate and enter the world of work, they make the transition from an academic to a professional community of knowledge. The importance of oral and written communication to the professional success and advancement of engineers is well documented. For example, studies such as those conducted by Mailloux (1989) indicate that communicating data, information, and knowledge takes up as much as 80% of an engineer's time. However, these same studies also indicate that many engineering graduates cannot (a) write technical reports that effectively inform and influence decisionmaking, (b) present their ideas persuasively, and (c) communicate with their peers. If these statements are true, how is learning to communicate effectively in their professional knowledge community different for engineering students educated in the United States but who come from other cultures-cultures in which English is not the primary language of communication? Answering this question requires adequate and generalizable data about these students' communications abilities, skills, and competencies. To contribute to the answer, we undertook a national (mail) survey of 1,727 student members of the American Institute of Aeronautics and Astronautics (AIAA). The focus of our analysis and this paper is a comparison of the responses of 297 student members for whom English is a second language with the responses of 1,430 native English speaking students to queries regarding career choice, bilingualism and language fluency, communication skills, collaborative writing, computer use, and the use of electronic (computer) networks.

  20. Design, construction, operation, and evaluation of a prototype culm combustion boiler/heater unit. Quarterly technical progress report, October 1-December 21, 1981

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    This report provides a summary of the work performed on the Prototype Culm Combustion Boiler/Heater Unit, Phase I - Engineering Design and Analysis, Phase II - Prototype Plant Construction and Phase III - Start-Up and Operation during the period October 1, 1981 through December 31, 1981. The objectives of the program as well as the technical progress and problem areas encountered during the reporting period are presented. Seven shakedown tests were run. Start-up and shakedown testing was completed. Four parametric tests were run. Performance data are presented with the exception of boiler efficiency which will be reported once chemical analyses are completed. Total boiler operation time through the end of this quarter - 1225 h, 50 min; operating time on culm and culm/limestone - 682 h, 43 min. Inspection revealed no problems with boiler tube wear. Sulfur capture greater than 94% was demonstrated (design is 88%). A turndown of better than 4 to 1 was shown (design is 2.5 to 1). Computer control of most of the loops has been successful and manual control was also demonstrated.

  1. First record of harpacticoid copepods from Lake Tahoe, United States: two new species of Attheyella (Harpacticoida, Canthocamptidae

    Directory of Open Access Journals (Sweden)

    Hyun Woo Bang

    2015-01-01

    Full Text Available Benthic harpacticoids were collected for the first time at Lake Tahoe, California-Nevada, United States. Two species were identified as members of the genus Attheyella Brady, 1880. The genus Attheyella comprises about 150 species within six subgenera, but only twelve species have previously been reported from North American freshwater habitats. The two new species of Attheyella described here have a 3-segmented endopod on P1 and 2-segmented P2–P4 endopods, the distal segment of exopod of P2–P4 has three outer spines, and the P5 has five setae on the exopod and six setae on the baseoendopod. Attheyella (Attheyella tahoensis sp. n. most closely resembles A. (A. idahoensis (Marsh, 1903 from Idaho, Montana, and Alaska (United States and A. (A. namkungi Kim, Soh & Lee, 2005 from Gosu Cave in South Korea. They differ mainly by the number of setae on the distal endopodal segment of P2–P4. In addition, intraspecific variation has been observed on the caudal rami. Attheyella (Neomrazekiella tessiae sp. n. is characterized by the extension of P5 baseoendopod, 2-segmented endopod of female P2–P3, and naked third seta of male P5 exopod. The two new species are likely endemic to Lake Tahoe, an isolated alpine lake within the Great Basin watershed in the western United States.

  2. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball and W. Zeuner

    2011-01-01

      Operational experience 2011 CMS is approaching the end of a very successful year of operation. Proton- proton running ended in the late afternoon of 30th October with a stunning 5.73 fb–1 delivered by LHC, of which CMS recorded 5.22 fb–1. During heavy-ion operation, which continues until 7th December, both the accelerator and the CMS detector have also performed very well. Despite the encouraging overall reliability of technical operation, several infrastructure failures which occurred since the last Bulletin are worthy of mention, with one leading for the first time to significant data-loss. On 10th July, a CERN-wide power failure brought down essentially all services including the magnet, due to an MCS setting being left in “manual” after the recent technical stop, but there was no significant damage and the detector was operational before the LHC, despite a slow and tortuous recovery (one of several indications this year that there is room for improve...

  3. A multitree perspective of the tree ring tropical cyclone record from longleaf pine (Pinus palustris Mill.), Big Thicket National Preserve, Texas, United States

    Science.gov (United States)

    Lewis, Daniel B.; Finkelstein, David B.; Grissino-Mayer, Henri D.; Mora, Claudia I.; Perfect, Edmund

    2011-06-01

    Tree rings afford the temporal resolution needed to characterize extreme weather events such as tropical cyclones, their frequency and variability. External factors such as soil water isotopic variability, soil heterogeneity, and/or stand disturbance affect the isotopic composition of individual trees in a stand, resulting in inaccuracies in the record. Single-tree isotope chronologies should be tested against multiple-tree chronologies to determine whether individual trees sufficiently characterize tropical cyclone variability. Eight individual trees from two sites in Big Thicket National Preserve were analyzed to evaluate whether they synchronously record tropical cyclone events. The ability of individual isotope models to capture an event was low (≤50%), and individual trees did not always record similar events. A composite chronology from the Turkey Creek Unit identified 5 false positive years and missed five storms. The composite chronology from the Big Sandy Creek Unit identified 5 false positives and missed four storms. All but 3 false positive years were characterized by above average precipitation that followed below average precipitation in the previous year. This mimics the negative isotopic excursion expected from tropical cyclones. Another year (1991) was coincident with a strong El Niño event, resulting in a shift in the dominant moisture source for the Texas Gulf Coast. Drought conditions occurred in years where storms were missed, which dampened the 18O-depleted signal associated with tropical cyclones. These data show that the number of trees is critical for properly characterizing tropical cyclone frequency through time, especially for periods prior to reliable instrumental records.

  4. Superfund record of decision (EPA Region 9): McClellan Air Force Base, Basewide Groundwater Operable Unit, Sacramento, CA, May 11, 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The Interim Record of Decision (ROD) presents the interim remedial action for the Groundwater Operable Unit (Groundwater OU) at the McClellan Air Force Base (McClellan AFB) Superfund site in Sacramento, California. The Groundwater OU addresses all of the VOC-contaminated groundwater at McClellan AFB. The Groundwater OU remedy is designed to prevent the spread of contamination that is already in the groundwater by containing groundwater with concentrations greater than maximum contaminant levels (MCLs). The remedy is also designed to remove to the maximum extent practicable the mass of contamination that lies in that volume of the groundwater.

  5. 6MW Back Pressure Unit Technical Transformation in a Thermal Power Plant%某热电厂6 MW背压机组技术改造

    Institute of Scientific and Technical Information of China (English)

    郭峰; 胡庆兵; 何鹏

    2015-01-01

    To improve the utilization rate of energy, a thermal power plant planned to build a 6MW medi-um temperature sub-high pressure back pressure turbine generator unit, which would replace two 3MW medium temperature and medium pressure back pressure turbine generator units. At the same time, a 3 MW extraction condensing unit in the first phase of the project was converted into a back pressure tur-bine with post machine connected with the exhaust steam pipe in order to solve the problem of poor system stability caused by the low heat load in the off-season in the company. It used the exhaust steam of the back pressure turbine as its steam admission to maintain the stable operation of the back pressure machine. This paper analyzed the technical transformation. Using the back pressure turbine with high parameters instead of the one with low parameters can improve energy efficiency; reduce pollutant emis-sions to achieve the aim of saving energy, protecting the environment and enhancing the area resident’ s quality of life.%某热电厂为提高能源利用率,拟新建一台6 MW中温次高压背压式汽轮发电机组,替代2台3 MW中温中压背压式汽轮发电机组,同时为解决公司淡季热负荷低造成系统稳定性差的问题,将一期1台3 MW抽凝机组改造成后置机接在背压机排汽管道后,利用背压机排汽作为它的进汽,起到维持背压机稳定运行的作用。本文对此技术改造进行了分析,以高参数的背压机组替代低参数的背压机组,提高能源利用率,减少污染物排放总量,达到节约能源、保护环境、提高区域内居民生活质量的目的。

  6. Material related to Lwów (lwowiana in the collection of the Library of Kraków Technical University. An analysis of the records in acquisition inventories from the years 1946-1961

    Directory of Open Access Journals (Sweden)

    Agnieszka Górska

    2010-01-01

    Full Text Available Based on twelve oldest hand-written inventory registers of the former Kraków Technical University from the years 1946-1961, a list, and then individual bibliographical records of 377 titles of books published in Lwów between 1747-1939 that are currently held at the Library, have been produced. In the article, the thematic scope of the materials related to Lwów is identified and characterized, which is followed by an analysis of the following formal features: chronological and typographical range of the publications (identification of publishing establishments or institutions most frequently represented in the collection, and their general characteristics. The group of books discussed in the study mainly includes technical textbooks written by such prominent lecturers of the Technical College in Lwów (Politechnika Lwowska as Maksymilian Thullie, Stefan Bryła, Maksymilian Matakiewicz, as well as other technical publications written by, for example, Karol Skibiński. The collection also includes literary works written by Polish and foreign authors, guidebooks and titles related to the history of Poland and the world, history of art, the art of painting, etc. The publications under scrutiny were published by various Lwów-based publishing houses such as Książnica Atlas, Zakład Narodowy im. Ossolińskich (the Ossolineum Institute and Wydawnictwo Polskie. Other initiators of publishing the research and scientific material included bookshop-cum-publishing establishments such as Księgarnia Polska Bernarda Połonieckiego.

  7. Student Records

    Science.gov (United States)

    Fields, Cheryl

    2005-01-01

    Another topic involving privacy has attracted considerable attention in recent months--the "student unit record" issue. The U.S. Department of Education concluded in March that it would be feasible to help address lawmakers' concerns about accountability in higher education by constructing a database capable of tracking students from institution…

  8. Isotope evidence of paleo - El Nino - Southern Oscillation cycles in loess-paleosol record in the central United States

    Science.gov (United States)

    Wang, Hongfang; Follmer, L.R.; Chao-li, Liu

    2000-01-01

    The ??13C of soil carbonate in rhizoconcretions collected from a loess-paleosol sequence in the central United States indicates that growing-season C3/C4 plant ratio oscillated by 35% on a 900 ?? 200 yr time scale during the late Wisconsinan glaciation. The pattern appears in phase with advance and retreat of the southern margin of the Laurentide ice sheet, suggesting influence by paleo-El Nin??o-Southern Oscillation cycles. The ??13C of soil organic matter indicates that the annual average C3/C4 plant ratio oscillated only by 18%, with a periodicity of 450 ?? 100 yr, and closely matched the cyclic pattern of loess-paleosol layers. It suggests a periodic enhancement of the penetration of the Gulf of Mexico air over the region during this time.

  9. Turbidite megabeds in an Oceanic Rift Valley recording jokulhlaups of late Pleistocene glacial lakes of the western United States

    Science.gov (United States)

    Zuffa, G.G.; Normark, W.R.; Serra, F.; Brunner, C.A.

    2000-01-01

    Escanaba Trough is the southernmost segment of the Gorda Ridge and is filled by sandy turbidites locally exceeding 500 m in thickness. New results from Ocean Drilling Program (ODP) Sites 1037 and 1038 that include accelerator mass spectrometry (AMS) 14C dates and revised petrographic evaluation of the sediment provenance, combined with high-resolution seismic-reflection profiles, provide a lithostratigraphic framework for the turbidite deposits. Three fining-upward units of sandy turbidites from the upper 365 m at ODP Site 1037 can be correlated with sediment recovered at ODP Site 1038 and Deep Sea Drilling Program (DSDP) Site 35. Six AMS 14C ages in the upper 317 m of the sequence at Site 1037 indicate that average deposition rates exceeded 10 m/k.yr. between 32 and 11 ka, with nearly instantaneous deposition of one ~60-m interval of sand. Petrography of the sand beds is consistent with a Columbia River source for the entire sedimentary sequence in Escanaba Trough. High-resolution acoustic stratigraphy shows that the turbidites in the upper 60 m at Site 1037 provide a characteristic sequence of key reflectors that occurs across the floor of the entire Escanaba Trough. Recent mapping of turbidite systems in the northeast Pacific Ocean suggests that the turbidity currents reached the Escanaba Trough along an 1100-km-long pathway from the Columbia River to the west flank of the Gorda Ridge. The age of the upper fining-upward unit of sandy turbidites appears to correspond to the latest Wisconsinan outburst of glacial Lake Missoula. Many of the outbursts, or jokulhlaups, from the glacial lakes probably continued flowing as hyperpycnally generated turbidity currents on entering the sea at the mouth of the Columbia River.

  10. Technical note: Quantifying and characterizing behavior in dairy calves using the IceTag automatic recording device

    DEFF Research Database (Denmark)

    Trénel, P.; Jensen, Margit Bak; Decker, Erik Luc

    2009-01-01

    The objectives of the current study were 1) to validate the IceTag ( http://www.icerobotics.com/ ) automatic recording device for measuring lying, standing, and moving behavior in dairy calves, and 2) to improve the information yield from this device by applying a filtering procedure allowing...... for the detection of lying versus upright. The IceTag device provides measures of intensity (I) of lying, standing, and activity measured as percent lying, percent standing, and percent active, but does not directly measure lying, standing, and moving behavior because body movements occurring while lying (e...... (LPC) was established empirically, and IceTag data were filtered according to the LPC, providing information on the posture of the animal as lying versus being upright. Third, a new threshold of I was estimated for moving activity conditional on the animal being upright. IceTag recordings from 9 calves...

  11. 32 CFR 701.38 - Technical data.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Technical data. 701.38 Section 701.38 National... DOCUMENTS AFFECTING THE PUBLIC FOIA Definitions and Terms § 701.38 Technical data. Recorded information, regardless of form or method of the recording, of a scientific or technical nature (including...

  12. Technical Agency in Practice

    DEFF Research Database (Denmark)

    Krummheuer, Antonia Lina

    2015-01-01

    The paper combines the discussion of technical agency and hybrid networks of Actor-Network Theory (ANT) with an ethnomethodological/conversation analytical (EMCA) perspective on situated practices in which participants ascribe agency to technical artefacts. While ANT works with (ethnographic......) description of hybrid networks in which human and non-human actants are granted agency without differentiating different kinds of agency, EMCA focuses on the member's perspectives and the situated construction of technical agency that is made relevant within an ongoing interaction. Based on an EMCA analysis...... of three video recordings of situations in which technical agency is made relevant by the human participants, the paper demonstrates different ways in which agency is granted to technical artefacts. Human participants can treat a technology as communication partner, as an active part (and actant...

  13. Technical Agency in Practice

    DEFF Research Database (Denmark)

    Krummheuer, Antonia Lina

    2015-01-01

    ) description of hybrid networks in which human and non-human actants are granted agency without differentiating different kinds of agency, EMCA focuses on the member's perspectives and the situated construction of technical agency that is made relevant within an ongoing interaction. Based on an EMCA analysis......The paper combines the discussion of technical agency and hybrid networks of Actor-Network Theory (ANT) with an ethnomethodological/conversation analytical (EMCA) perspective on situated practices in which participants ascribe agency to technical artefacts. While ANT works with (ethnographic...... of three video recordings of situations in which technical agency is made relevant by the human participants, the paper demonstrates different ways in which agency is granted to technical artefacts. Human participants can treat a technology as communication partner, as an active part (and actant...

  14. [Hepatitis C patients' record in the Sentinel Units for viral Hepatitis in Argentina 2007- 2014. Distribution by year of birth].

    Science.gov (United States)

    Vladimirsky, Sara Noemí; Munné, Maria Silvina; Otegui, Lucio Oscar; Altabert, Nancy Roxana; Soto, Sonia Soledad; Brajterman, Leonardo; González, Jorge Enrique

    2015-06-01

    Recommendations for Hepatitis C screening based on risk factorsfor transmission proved to be ineffcient. Accordingly, the CDC recommended to screen all American individuals born between 1945-1965, based on data from population prevalence of infection. The effectiveness of implementing these recommendations in other contexts and/or populations can be estimated, in principle, knowing the age distribution of infected individuals. There is no data on population prevalence in our country. Yet we can know the age distribution of cases of Hepatitis C who accessed the health system. The aim of this paper is to analyze the distribution by birth cohort ofcases registered as "Hepatitis C" in the Sentinel Units for Viral Hepatitis in the 2007-2014 period. This will contribute to the identification, if any, ofa cohort in which case the recommendation of screening could be addressed, based on risk factors inherent to our country and our epidemiological reality. The age distribution of our cases was wider and younger than those of the population supporting the recommendation of the CDC and this suggests -beyond the difference in the populations being compared- is due to a range of risk factors and age at different infection between USA and Argentina. Thus, based on these results, the recommendation of the Argentine Consensus for Hepatitis C in 2013 to screen all individuals once in life is supported.

  15. First definitive record of a stygobiotic fish (Percopsiformes, Amblyopsidae, Typhlichthys from the Appalachians karst region in the eastern United States

    Directory of Open Access Journals (Sweden)

    Matthew L. Niemiller

    2016-11-01

    Full Text Available In the central and eastern United States, cavefishes have been known historically only from the Interior Low Plateau and Ozarks karst regions. Previously, cavefishes were unknown from the Appalachians karst region, which extends from southeastern New York southwestward into eastern Tennessee, northwestern Georgia, and northeastern Alabama. Here we report the discovery of a new population of the amblyopsid cavefish Typhlichthys subterraneus Girard, 1859 from a cave in Catoosa County, Georgia, that significantly extends the known distribution of the species. The cave is located in the Appalachian Valley and Ridge physiographic province and Appalachians karst region, and represents the first definitive report of a stygobiotic fish from the Appalachians karst region. Genetic analyses of one mitochondrial and one nuclear locus from the cavefish indicate this population is closely allied with populations that occur along the western margins of Lookout and Fox mountains in Dade County, Georgia, and populations to the northwest in southern Marion County, Tennessee. It is likely that these populations are also related to those from Wills Valley, DeKalb County, Alabama. The distribution of this new population of T. subterraneus and its close allies pre-dates the emergence of a Tennessee-Coosa River drainage divide in the Pliocene. The potential exists to discover additional populations in caves within the Appalachians karst region in Catoosa County and northward into Hamilton County, Tennessee.

  16. Relict nebkhas (pimple mounds) record prolonged late Holocene drought in the forested region of south-central United States

    Science.gov (United States)

    Seifert, Christopher L.; Cox, Randel Tom; Forman, Steven L.; Foti, Tom L.; Wasklewicz, Thad A.; McColgan, Andrew T.

    2009-05-01

    The origin and significance of pimple mounds (low, elliptical to circular dune-like features found across much of the south-central United States) have been debated for nearly two centuries. We cored pimple mounds at four sites spanning the Ozark Plateau, Arkansas River Valley, and Gulf of Mexico Coastal Plain and found that these mounds have a regionally consistent textural asymmetry such that there is a significant excess of coarse-grained sediment within their northwest flanks. We interpret this asymmetry as evidence of an eolian depositional origin of these mounds and conclude they are relict nebkhas (coppice dunes) deposited during protracted middle to late Holocene droughts. These four mounds yield optically stimulated luminescence ages between 2400 and 700 yr that correlate with well-documented periods of eolian activity and droughts on the southern Great Plains, including the Medieval Climate Anomaly. We conclude vegetation loss during extended droughts led to local eolian deflation and pimple mound deposition. These mounds reflect landscape response to multi-decadal droughts for the south-central U.S. The spatial extent of pimple mounds across this region further underscores the severity and duration of late Holocene droughts, which were significantly greater than historic droughts.

  17. Moisture Changes in the Mid-Holocene: Do PMIP3 Simulations Reflect the Proxy Record for the Western United States?

    Science.gov (United States)

    Hermann, N. W.; Oster, J. L.; Ibarra, D. E.

    2015-12-01

    Paleoclimate proxy-model comparisons for past warm periods provide insight into the driving mechanisms of persistent drought, especially pertinent information given the ongoing drought in the western US. A network of 110 hydrologically sensitive proxy records from lake sediments, speleothems, and packrat middens shows increased aridity in the western and northwestern U.S. and increased moisture in the southwest monsoon region during the mid-Holocene, a time of higher summer and lower winter insolation than present. We compare this proxy network to output from 12 climate models from the Paleoclimate Modeling Intercomparison Project Phase III (PMIP3) at the 6ka time slice to determine which models best reflect paleo-precipitation patterns, and therefore, the atmospheric drivers of precipitation change. We carry out a quantitative proxy-model comparison for precipitation (P) and effective moisture (EM = P - evapotranspiration) at 6ka relative to preindustrial simulations. Using a weighted Cohen's Kappa test, we evaluate model agreement at different thresholds of change for annual and seasonal anomalies. Overall, simulated P anomalies show better agreement with the proxy network than EM anomalies. The FGOALS-g2 (FG) model shows the best agreement with the proxy network for annual P anomalies, with increased annual P in the monsoonal southwestern US and northern Mexico, and decreased annual P in northern California, the northern Great Basin, and the Pacific Northwest at 6 ka relative to modern. FG simulates decreased winter P across the entire western US, increased autumn P in the monsoon region and decreased autumn P in the non-monsoon region. While other models simulate increased P from July-September in the monsoon region and more arid conditions at non-monsoon sites, they often do not simulate increased aridity in non-monsoon regions during other seasons. These differences may be due to a less defined autumn Aleutian Low in FG compared with most other models.

  18. Head-camera video recordings of trauma core competency procedures can evaluate surgical resident's technical performance as well as colocated evaluators.

    Science.gov (United States)

    Mackenzie, Colin F; Pasley, Jason; Garofalo, Evan; Shackelford, Stacy; Chen, Hegang; Longinaker, Nyaradzo; Granite, Guinevere; Pugh, Kristy; Hagegeorge, George; Tisherman, Samuel A

    2017-07-01

    Unbiased evaluation of trauma core competency procedures is necessary to determine if residency and predeployment training courses are useful. We tested whether a previously validated individual procedure score (IPS) for individual procedure vascular exposure and fasciotomy (FAS) performance skills could discriminate training status by comparing IPS of evaluators colocated with surgeons to blind video evaluations. Performance of axillary artery (AA), brachial artery (BA), and femoral artery (FA) vascular exposures and lower extremity FAS on fresh cadavers by 40 PGY-2 to PGY-6 residents was video-recorded from head-mounted cameras. Two colocated trained evaluators assessed IPS before and after training. One surgeon in each pretraining tertile of IPS for each procedure was randomly identified for blind video review. The same 12 surgeons were video-recorded repeating the procedures less than 4 weeks after training. Five evaluators independently reviewed all 96 randomly arranged deidentified videos. Inter-rater reliability/consistency, intraclass correlation coefficients were compared by colocated versus video review of IPS, and errors. Study methodology and bias were judged by Medical Education Research Study Quality Instrument and the Quality Assessment of Diagnostic Accuracy Studies criteria. There were no differences (p ≥ 0.5) in IPS for AA, FA, FAS, whether evaluators were colocated or reviewed video recordings. Evaluator consistency was 0.29 (BA) - 0.77 (FA). Video and colocated evaluators were in total agreement (p = 1.0) for error recognition. Intraclass correlation coefficient was 0.73 to 0.92, dependent on procedure. Correlations video versus colocated evaluations were 0.5 to 0.9. Except for BA, blinded video evaluators discriminated (p competency. Prognostic study, level II.

  19. Recording of electrical-evoked responses from a remote field in the vestibular part of the eighth nerve. A preliminary technical report.

    Science.gov (United States)

    Latkowski, B; Puzio, J

    1989-01-01

    The paper discusses the results of the author's own studies concerning the recording of electrical responses evoked from a remote field in the vestibular part of the eighth nerve. The studies are of experimental nature and they were carried out repetitively in guinea pigs. Particular attention is paid to an apparatus specially designed and constructed, permitting to obtain stimulation of adequate quality of vestibular organs, and to receive and average short (up to 10 ms) evoked vestibular potentials. Different variants of elimination of bioelectrical muscular disturbances and of the auditory pathway are proposed.

  20. Electroencephalographic Patterns Recorded by Continuous EEG Monitoring in Patients with Change of Consciousness in the Neurological Intensive Care Unit.

    Science.gov (United States)

    Altindağ, Ebru; Okudan, Zeynep Vildan; Tavukçu Özkan, Sedef; Krespi, Yakup; Baykan, Betül

    2017-06-01

    Our aim was to examine the frequency of various electrographic patterns including periodic discharges (PD), repetitive spike waves (RSW), rhythmic delta activities (RDA), nonconvulsive seizures (NCS) and nonconvulsive status epilepticus (NCSE) in continuous EEG monitoring (cEEG) of the critically ill patients with change of consciousness and the presence of specific clinical and laboratory findings associated with these important patterns in this study. Patients with changes of consciousness in the neurological intensive care unit (NICU) were consecutively monitored with cEEG during 2 years. Their clinical, electrophysiological, radiological and laboratory findings were evaluated retrospectively. This sample consisted of 57 (25 men) patients with a mean age of 68.2 years. Mean duration of cEEG monitoring was 2532.6 minutes. The most common electrographic patterns were PD (33%) and NCS-NCSE (26.3%). The presence of NCS-NCSE was significantly associated with PD (57.9%, p<0.001). PD and NCS-NCSE were the mostly seen in patients with acute stroke and hypoxic encephalopathy. Duration of monitoring was significantly longer in the group with PD and NCS-NCSE (p:0.004, p:0.014). Detection of any electrographic pattern in EEG before monitoring was associated with the presence of any pattern in cEEG (59.3%, p<0.0001). Convulsive or nonconvulsive seizure during monitoring was common in patients with electrographic patterns (p<0.0001). 66.7% of NCS-NCSE was seen within the first 12 hours and 26.7% was seen within the 12-24 hours of the monitoring. Detection of any electrographic pattern in EEG before monitoring was associated with the presence of any important pattern in cEEG monitoring. This association suggest that at least 24 hours-monitoring of these patients could be useful for the diagnosis of clinical and/or electrographic seizures.

  1. Rate of first recorded diagnosis of autism and other pervasive developmental disorders in United Kingdom general practice, 1988 to 2001

    Directory of Open Access Journals (Sweden)

    Smith Peter G

    2004-11-01

    Full Text Available Abstract Background There has been concern that the incidence of autism and other pervasive developmental disorders (PDDs is increasing. Previous studies have been smaller, restricted to autism (excluding other pervasive developmental disorders such as Asperger's syndrome, included boys only, or have not been based on a national sample. We investigated time trends in the rates of diagnosis of pervasive developmental disorders. Methods We analysed the rates of first diagnosis of pervasive developmental disorders among people registered with a practice contributing to the United Kingdom General Practice Research Database during the period 1988 to 2001. We included 1410 cases from over 14 million person-years of observation. The main outcome measures were rates of diagnosis of pervasive developmental disorders by year of diagnosis, year of birth, gender and geographical region. Results The rate increased progressively from 0.40/10,000 person-years (95% CI 0.30 to 0.54 in 1991 to 2.98/10,000 (95% CI 2.56 to 3.47 in 2001. A similar change occurred in the age standardised incidence ratios, from 35 (95% CI: 26–47 in 1991 to 365 (95% CI: 314–425 in 2001. The temporal increase was not limited to children born during specific years nor to children diagnosed in a specific time period. The rate of diagnosis of PDDs other than autism rose from zero for the period 1988–1992 to 1.06/10,000 person-years in 2001. The rate of diagnosis of autism also increased but to a lesser extent. There was marked geographical variation in rates, with standardised incidence ratios varying from 66 for Wales to 141 for the South East of England. Conclusions Better ascertainment of diagnosis is likely to have contributed to the observed temporal increase in rates of diagnosis of PDD, but we cannot exclude a real increase.

  2. Technical Note: Harmonized retrieval of column-integrated atmospheric water vapor from the FTIR network – first examples for long-term records and station trends

    Directory of Open Access Journals (Sweden)

    C. Servais

    2009-11-01

    Full Text Available We present a method for harmonized retrieval of integrated water vapor (IWV from existing, long-term, measurement records at the ground-based mid-infrared solar FTIR spectrometry stations of the Network for the Detection of Atmospheric Composition Change (NDACC. Correlation of IWV from FTIR with radiosondes shows an ideal slope of 1.00(3. This optimum matching is achieved via tuning one FTIR retrieval parameter, i.e., the strength of a Tikhonov regularization constraining the derivative (with respect to height of retrieved water profiles given in per cent difference relative to an a priori profile. All other FTIR-sonde correlation parameters (intercept=0.02(12 mm, bias=0.02(5 mm, standard deviation of coincident IWV differences (stdv=0.27 mm, R=0.99 are comparable to or better than results for all other ground-based IWV sounding techniques given in the literature. An FTIR-FTIR side-by-side intercomparison reveals a strong exponential increase in stdv as a function of increasing temporal mismatch starting at Δt≈1 min. This is due to atmospheric water vapor variability. Based on this result we derive an upper limit for the precision of the FTIR IWV retrieval for the smallest Δt(=3.75 min still giving a statistically sufficient sample (32 coincidences, i.e., precision(IWVFTIR As first application examples long-term IWV data sets are retrieved from the FTIR records of the Zugspitze (47.4° N, 11.0° E, 2964 m a.s.l. and Jungfraujoch (46.5° N, 8.0° E, 3580 m a.s.l. NDACC sites. Station-trend analysis comprises a linear fit after subtracting an intra-annual model (3 Fourier components and constructing an uncertainty interval [95% confidence] via bootstrap resampling. For the Zugspitze a significant trend of 0.79 [0.65, 0.92] mm/decade is found for the time interval [1996–2008], whereas for the Jungfraujoch no significant trend is found. This confirms recent findings that strong variations of IWV trends do occur above land on the local to

  3. Superfund record of decision (EPA Region 9): Carson River Mercury Site, operable unit 1, Lyon, Storey and Churchill County, NV, March 30, 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-06-01

    The Record of Decision (ROD) presents the selected remedial action for Operable Unit 1 (OU-1) of the Carson River Mercury Site (CRMS) which is located in Lyon, Storey and Churchill Counties, Nevada. The selected remedy for the five residential yards is to excavate contaminated surface soil (estimated to go to a depth of approximately 2 feet below ground surface), dispose of the soil at the RCRA municipal landfill if the soils do not exceed the TCLP standards, and restore the excavated areas. If it is determined that all or part of the excavated soil exceeds the TCLP standards, then the excavated soil will either be treated and disposed of at a RCRA municipal landfill or disposed of at the RCRA hazardous waste landfill.

  4. On the Edge of Life, I: Assessment of, Reaction to, and Management of the Terminally Ill Recorded in an Intensive Care Unit Journal.

    Science.gov (United States)

    Sekeres, Mikkael A.; Stern, Theodore A.

    2002-10-01

    BACKGROUND: In a general hospital, few clinical settings match the intensity of the intensive care unit (ICU) experience. Clinical rotations in ICUs elicit and emphasize the struggles house officers face on a daily basis throughout their training. METHOD: These struggles were recorded by hundreds of residents in a journal maintained in the Massachusetts General Hospital's Medical ICU for the past 20 years. We systematically reviewed these unsolicited entries to define and to illustrate how house officers respond to caring for terminally ill patients. The 3 overarching topics that surfaced repeatedly were assessment of terminally ill patients, reaction to their prognosis, and management of their disease or their eventual demise. RESULTS: House officers record affective reactions and cognitive assessments to cope with the stress and dysfunction associated with the care of the critically ill and to facilitate their management of these patients. Journal entries by residents reveal a deep concern for the welfare of their patients, conflict about the technological advances and limitations of the system, and reflection on how involved physicians should become with their patients. CONCLUSION: House officer journal entries reflect a combination of newly gained medical knowledge and coping strategies in managing terminally ill patients. House officers also demonstrate a deep concern for the welfare of their patients. Insight from years of reflection from past house officers can help prepare trainees and residency programs for the breadth and intensity of the ICU experience and for work in clinical practice settings that follow completion of training.

  5. Satisfaction of health-care providers with electronic health records and perceived barriers to its implementation in the United Arab Emirates.

    Science.gov (United States)

    Bani-Issa, Wegdan; Al Yateem, Nabeel; Al Makhzoomy, Ibtihal Khalaf; Ibrahim, Ali

    2016-08-01

    The integration of electronic health records (EHRs) has shown promise in improving health-care quality. In the United Arab Emirates, EHRs have been recently adopted to improve the quality and safety of patient care. A cross-sectional survey of 680 health-care providers (HCPs) was conducted to assess the satisfaction of HCPs in the United Arab Emirates with EHRs' impact on access/viewing, documentation and medication administration and to explore the barriers encountered in their use. Data were collected over 6 months from April to September 2014. High overall satisfaction with EHRs was reported by HCPs, suggesting their acceptance. Physicians reported the greatest overall satisfaction with EHRs, although nurses showed significantly higher satisfaction with the impact on medication administration compared with other HCPs. The most significant barriers reported by nurses were lack of belief in the value of EHRs for patients and lack of adequate computer skills. Given the large investment in technology, additional research is necessary to promote the full utilization of EHRs. Nurses need to be aware of the value of EHRs for patient care and be involved in all stages of EHR implementations to maximize its meaningful use for better clinical outcomes.

  6. 浅谈如何做好科技档案收集工作%Discuss on how to do a good job of technical record collection

    Institute of Scientific and Technical Information of China (English)

    薛健

    2016-01-01

    随着经济发展和科技进步,科技档案的开发利用取得很大进展,但是科技档案收集工作仍做得不够到位,需要进一步改进完善。结合科研单位实际情况,从增强科技档案人员收集意识、建立健全收集机制、创新收集方法、强化人员培训等方面进行研究探讨,为做好科技档案收集工作提供一些借鉴。%As the economic development and the progress of science and technology, great progress was made in the development and utilization of science and technology archives, but it still needs to be further improved. Combining with the practical situation of scientific research units, this paper discussed on aspects of strengthening collection consciousness, establishing collection mechanism, innovating collection methods and strengthening personnel training, etc, and provided some reference for archives collection work.

  7. Technical Agency in Practice

    DEFF Research Database (Denmark)

    Krummheuer, Antonia Lina

    2015-01-01

    ) description of hybrid networks in which human and non-human actants are granted agency without differentiating different kinds of agency, EMCA focuses on the member's perspectives and the situated construction of technical agency that is made relevant within an ongoing interaction. Based on an EMCA analysis...... of three video recordings of situations in which technical agency is made relevant by the human participants, the paper demonstrates different ways in which agency is granted to technical artefacts. Human participants can treat a technology as communication partner, as an active part (and actant...... in which the human participants orient towards the artefact in different ways; thereby, the construction of technical agency can shift from moment to moment....

  8. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball and W. Zeuner

    2012-01-01

      UXC + detectors As explained in detail in the November 2011 bulletin, the bellows unit at −18.5 m from the CMS interaction point was identified as a prime candidate for the regularly occurring pressure spikes which occasionally led to sustained severe background conditions in 2011, affecting dead time and data quality. Similar regions in LHC with vacuum instabilities were observed to be close to bellows, which radiography showed to have distorted RF-fingers — on removal, they proved to have been severely overheated. The plans for the Year-End Technical Stop were adapted to prioritise radiography of the bellows at 16 m to 18 m either end of CMS. Excellent work by the beam pipe, survey and heavy mechanical teams allowed the X-rays to be taken as planned on 20th December, showing that the bellow at −18.5m had an obvious non-conformity. The RF-fingers were found inside the end of the opposing flared pipe instead of outside. In addition, the overlap between fingers and...

  9. Fatores técnicos intervenientes na realização do exame de eletrorretinograma multifocal (ERGmf Technical factors that influence multifocal electroretinogram (mfERG recording

    Directory of Open Access Journals (Sweden)

    Maria Kiyoko Oyamada

    2007-08-01

    adequada da amplitude e do tempo implícito dos picos N1 e P1, fundamentais para a corroboração diagnóstica de lesões ou afecções retinianas.PURPOSE: To describe the main intervening factors observed during the acquisition and analysis of multifocal electroretinogram (mfERG, that could affect the recorded signal, the obtained responses and their analysis. METHODS: The error factors observed during the acquisition of 100 sequential multifocal electroretinogram tests, in the period of May to July, 2005 were analyzed. The examinations of multifocal electroretinogram were carried out in agreement with international guideline recommendations, taking into account the established parameters of equipment, with 61 elements, and visual angle of 30º. All patients had been submitted to complete ophthalmologic examination, excluding those with inadequate transparency of ways, flat corneas and those incapable to visualize a central fixation target. RESULTS: The intervening factors, that could cause artifacts and errors in the interpretation of the obtained results, observed and corrected during the acquisition of multifocal electroretinogram were: eccentric or poor fixation, eye movements, orbicular contraction, cervical muscle contraction, inadequate transparency of the corneal electrode, electrode displacement, lens support decentralization, inadequate viewing distance in patients with high refractive errors, eye height inadequacy in relation to the center of the screen, electrical noise in 60 HZ frequency and electromagnetic field and high impedances. Excessive use of filters in wave processing for noise and artifact removal can interfere with the analysis of the obtained results. CONCLUSION: Simple observational cares during signal acquisition are of significant importance to ensure accuracy of the topographical electroretinogram information, good waveform morphology and low noise level register. Through their ready correction, the correct and adjusted analysis of the

  10. Fuel Cell Technical Team Roadmap

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-06-01

    The Fuel Cell Technical Team promotes the development of a fuel cell power system for an automotive powertrain that meets the U.S. DRIVE Partnership (United States Driving Research and Innovation for Vehicle efficiency and Energy sustainability) goals.

  11. A computer-assisted recording, diagnosis and management of the medically ill system for use in the intensive care unit: A preliminary report

    Directory of Open Access Journals (Sweden)

    John George

    2009-01-01

    Full Text Available Background: Computerized medical information systems have been popularized over the last two decades to improve quality and safety, and for decreasing medical errors. Aim: To develop a clinician-friendly computer-based support system in the intensive care unit (ICU that incorporates recording, reminders, alerts, checklists and diagnostic differentials for common conditions encountered in critical care. Materials and Methods: This project was carried out at the Medical ICU CMC Hospital, Vellore, in collaboration with the Computer Science Department, VIT University. The first phase was to design and develop monitoring and medication sheets. Terminologies such as checklists (intervention list that pops up at defined times for all patients, reminders (intervention unique to each patient and alerts (time-based, value-based, trend-based were defined. The diagnostic and intervention bundles were characterized in the second phase. The accuracy and reliability of the software to generate alerts, reminders and diagnoses was tested in the third phase. The fourth phase will be to integrate this with the hospital information system and the bedside monitors. Results: Alpha testing was performed using six scenarios written by intensivists. The software generated real-time alerts and reminders and provided diagnostic differentials relevant to critical care. Predefined interventions for each diagnostic possibility appeared as pop-ups. Problems identified during alpha testing were rectified prior to beta testing. Conclusions: The use of a computer-assisted monitoring, recording and diagnostic system appears promising. It is envisaged that further software refinements following beta testing would facilitate the improvement of quality and safety in the critical care environment.

  12. Technical reference book for the Energy Economic Data Base (EEDB) Program

    Energy Technology Data Exchange (ETDEWEB)

    Allen, R.E.; Benedict, R.G.; Hodson, J.S.

    1984-09-01

    The Energy Economic Data Base (EEDB) Program is sponsored by the US Department of Energy (DOE) for the purpose of developing current technical and cost information for nuclear and comparison electric power generating stations. The EEDB contains a variety of nuclear and coal-fired power plant technical data models. Each of these data models is a complete and detailed conceptual design for a single unit, commercial, steam electric, power generating station located on a standard hypothetical Middletown site. A major effort for the Sixth Update (1983) has been the updating of the system design descriptions and selected engineering drawings for the technical data models. This update took the form of revising and expanding the system design descriptions and engineering drawings contained in the Base Data Studies, to include the technical information developed and recorded in the first five EEDB updates. The results of the update effort are contained in this EEDB Program Technical Reference Book.

  13. The environment recording unit in coral skeletons: structural and chemical evidences of a biochemically driven stepping-growth process in coral fibres

    Directory of Open Access Journals (Sweden)

    Y. Dauphin

    2004-09-01

    Full Text Available To improve our understanding of the environment recording by scleractinian corals, a detailed study of the skeleton microstructure has been carried out. A series of physico-chemical in situ characterizations was made, an approach that provides us with structural and biochemical information at the micrometric and nanometric scales. Gathering of these data results in a significant change in our concept of the growth of coral skeletons. In contrast to the usual view of an aggregate of purely mineral units (the coral fibres independently growing by a simple chemical precipitation, coral skeletons appear to be biochemically controlled structures. Both structural and biochemical data reveal the micron-scaled stepping growth-mode of fibres, and its global coordination. In this process, sulfated acidic proteoglycans probably play a major role, due to their ability to create polymeric frameworks. Atomic force microscopy confirms the close relationship of organic and mineral phases at the nanometric scale. A new microstructural model of coral skeleton formation is proposed, that places coral skeletons among the typical "matrix mediated structures". From a practical standpoint, these results may contribute to develop a new high resolution approach in the study of paleoenvironments.

  14. Superfund Record of Decision (EPA Region 9): Andersen Air Force Base, Operable Unit 3 (MARBO Annex), Yigo, Guam, June 16, 1998

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    This decision document, a Record of Decision (ROD), presents the selected remedial actions for soil and groundwater at the Marianas/Bonnis Command (MARBO) Annex Operable Unit (OU) at Andersen Air Force Base (AFB), Guam. No risk was found at Waste Pile 5 and the War Dog Borrow Pit, so no further action is planned for these two sites. Current risks associated with soil exceed acceptable risk levels at Waste Pile 6, Waste Pile 7, Landfill 29, and the MARBO Laundry. Based on alternatives evaluated in the OU 3 Focused FS the US Air Force, the USEPA, and Guam have selected Soil Removal (Alternative OU3-D) as the remedy for three of the sites, and Soil Cover (Alternative OU3-C) for one of the sites. Based on alternatives evaluated in the OU-2 Focused FS, the USAF, the USEPA, and the Guam EPA have selected Natural Attenuation with Wellhead Treatment (Alternative G-2) as the remedy for the TCE and PCE contaminated groundwater beneath the MARBO Annex.

  15. A short note on ground-motion recordings from the M 7.9 Wenchuan, China, earthquake and ground-motion prediction equations in the Central and Eastern United States

    Science.gov (United States)

    Wang, Z.; Lu, M.

    2011-01-01

    The 12 May 2008 Wenchuan earthquake (M 7.9) occurred along the western edge of the eastern China SCR and was well recorded by modern strong-motion instruments: 93 strong-motion stations within 1.4 to 300 km rupture distance recorded the main event. Preliminary comparisons show some similarities between ground-motion attenuation in the Wenchuan region and the central and eastern United States, suggesting that ground motions from the Wenchuan earthquake could be used as a database providing constraints for developing GMPEs for large earthquakes in the central and eastern United States.

  16. Forecasts of forest conditions in regions of the United States under future scenarios: a technical document supporting the Forest Service 2012 RPA Assessment

    Science.gov (United States)

    David N. Wear; Robert Huggett; Ruhong Li; Benjamin Perryman; Shan Liu

    2013-01-01

    The 626 million acres of forests in the conterminous United States represent significant reserves of biodiversity and terrestrial carbon and provide substantial flows of highly valued ecosystem services, including timber products, watershed protection benefits, and recreation. This report describes forecasts of forest conditions for the conterminous United States in...

  17. 深圳区域电子病历智能化搜索引擎技术要点%Technical Points of Smart Search Engine for Regional Electronic Medical Record in Shenzhen

    Institute of Scientific and Technical Information of China (English)

    朱远燕; 林德南; 潘景波

    2015-01-01

    智能化搜索引擎能使用户对区域电子病历的检索操作更加方便、快捷,加速电子病历文档的检索过程,并且使所获得的搜索结果的相关性更好、精确度更高.从而有效地改善用户的搜索体验,促进电子病历利用率的提高.更好地发挥区域电子病历在临床医疗诊断、治疗和护理及科研方面的辅助作用.本文简单介绍深圳市区域电子病历智能化搜索引擎研发中的一些技术要点.%The technical points of smart search engine for REMR in Shenzhen is introduced briefly in this paper. The smart search engine can make the searching process easier and quicker and let the users get more relevant and accurate results from the Regional Electronic Medical Record(REMR). Therefore,this can improve the users' experience and promote the application of REMR in clinical diagnosis,treatment,nursing and scientific research.

  18. Non-technical skills of surgical trainees and experienced surgeons.

    Science.gov (United States)

    Gostlow, H; Marlow, N; Thomas, M J W; Hewett, P J; Kiermeier, A; Babidge, W; Altree, M; Pena, G; Maddern, G

    2017-05-01

    In addition to technical expertise, surgical competence requires effective non-technical skills to ensure patient safety and maintenance of standards. Recently the Royal Australasian College of Surgeons implemented a new Surgical Education and Training (SET) curriculum that incorporated non-technical skills considered essential for a competent surgeon. This study sought to compare the non-technical skills of experienced surgeons who completed their training before the introduction of SET with the non-technical skills of more recent trainees. Surgical trainees and experienced surgeons undertook a simulated scenario designed to challenge their non-technical skills. Scenarios were video recorded and participants were assessed using the Non-Technical Skills for Surgeons (NOTSS) scoring system. Participants were divided into subgroups according to years of experience and their NOTSS scores were compared. For most NOTSS elements, mean scores increased initially, peaking around the time of Fellowship, before decreasing roughly linearly over time. There was a significant downward trend in score with increasing years since being awarded Fellowship for six of the 12 NOTSS elements: considering options (score -0·015 units per year), implementing and reviewing decisions (-0·020 per year), establishing a shared understanding (-0·014 per year), setting and maintaining standards (-0·024 per year), supporting others (-0·031 per year) and coping with pressure (-0·015 per year). The drop in NOTSS score was unexpected and highlights that even experienced surgeons are not immune to deficiencies in non-technical skills. Consideration should be given to continuing professional development programmes focusing on non-technical skills, regardless of the level of professional experience. © 2017 BJS Society Ltd Published by John Wiley & Sons Ltd.

  19. Improvements in State and Local Planning for Mass Dispensing of Medical Countermeasures: The Technical Assistance Review Program, United States, 2007-2014.

    Science.gov (United States)

    Renard, Paul G; Vagi, Sara J; Reinold, Chris M; Silverman, Brenda L; Avchen, Rachel N

    2017-09-01

    To evaluate and describe outcomes of state and local medical countermeasure preparedness planning, which is critical to ensure rapid distribution and dispensing of a broad spectrum of life-saving medical assets during a public health emergency. We used 2007 to 2014 state and local data collected from the Centers for Disease Control and Prevention's Technical Assistance Review. We calculated descriptive statistics from 50 states and 72 local Cities Readiness Initiative jurisdictions that participated in the Technical Assistance Review annually. From 2007 to 2014, the average overall Technical Assistance Review score increased by 13% for states and 41% for Cities Readiness Initiative jurisdictions. In 2014, nearly half of states achieved the maximum possible overall score (100), and 94% of local Cities Readiness Initiative jurisdictions achieved a score of 90 or more. Despite challenges, effective and timely medical countermeasure distribution and dispensing is possible with appropriate planning, staff, and resources. However, vigilance in training, exercising, and improving plans from lessons learned in a sustained, coordinated way is critical to ensure continued public health preparedness success.

  20. Technical Network

    CERN Multimedia

    2007-01-01

    In order to optimize the management of the Technical Network (TN), to ease the understanding and purpose of devices connected to the TN, and to improve security incident handling, the Technical Network Administrators and the CNIC WG have asked IT/CS to verify the "description" and "tag" fields of devices connected to the TN. Therefore, persons responsible for systems connected to the TN will receive email notifications from IT/CS asking them to add the corresponding information in the network database. Thank you very much for your cooperation. The Technical Network Administrators & the CNIC WG

  1. Technical Network

    CERN Multimedia

    2007-01-01

    In order to optimise the management of the Technical Network (TN), to facilitate understanding of the purpose of devices connected to the TN and to improve security incident handling, the Technical Network Administrators and the CNIC WG have asked IT/CS to verify the "description" and "tag" fields of devices connected to the TN. Therefore, persons responsible for systems connected to the TN will receive e-mails from IT/CS asking them to add the corresponding information in the network database at "network-cern-ch". Thank you very much for your cooperation. The Technical Network Administrators & the CNIC WG

  2. The Abrupt Climatic Changes During the Last Deglaciation: Direct Land-sea Correlation From a Marine Pollen Record off Southeastern United States

    Science.gov (United States)

    Desprat, S.; McManus, J. F.; Peteet, D.

    2007-12-01

    We present a new direct land-sea correlation covering the last deglaciation in order a) to provide a better documentation of the regional vegetation changes in southeastern North America and b) more particularly to assess the connection of the continental climatic changes to North Atlantic circulation rapid variability. It was achieved using coupled analyses of pollen and marine climatic proxies from core KNR140-GGC39 (Blake Outer Ridge) at very high time-resolution. Mg/Ca ratio, planktonic δ18O, mean "sortable silt" grain size (mean S¯S¯) were analyzed in order to get records of SST, salinity and bottom current strength at the core site (Evans et al., submitted to Paleoceanography). The abrupt climatic changes which characterize the last deglaciation, in particular the major cold oscillations Heinrich event 1 (H1) and Younger Dryas (YD), have been widely documented in the North Atlantic and adjacent continents. However, in the tropical and subtropical North Atlantic and southeastern United States, the climatic signature of these events appears quite different and somehow unclear. Our direct land-sea correlation shows three configurations: 1- H1 period: cold climatic conditions in southeastern US (high percentages of boreal and herbaceous taxa) but only extremely cold at around 17 ka, accumulation of salty water in the subtropics (high δ18OSW- IVC) and weak bottom current intensity at the site (low mean S¯S¯) 2- Bolling Alleröd interval: abrupt warming in southeastern US (decrease of boreal taxa in favour of Quercus) at the beginning, synchronous to northern export of the salty water previously accumulated and to an increase of the bottom current strength at the site 3- YD period: mild and wet conditions in southeastern US (expansion of Tsuga and Quercus), decrease of the bottom current strength at the site and accumulation of salty water in the subtropical regions but less than during H1.

  3. A Prospective Longitudinal Assessment of Medical Records for Diagnostic Substitution among Subjects Diagnosed with a Pervasive Developmental Disorder in the United States

    Directory of Open Access Journals (Sweden)

    David eGeier

    2015-10-01

    Full Text Available Background: Previously, investigators suggested that diagnostic substitution from other diagnoses, e.g., mental retardation (MR and/or cerebral palsy (CP to pervasive developmental disorder (PDD is a driving factor behind increases in PDD. This study evaluated potential diagnostic substitution among subjects diagnosed with PDD vs MR or CP by examining birth characteristic overlap.Methods: SAS® and StatsDirect software examined medical records for subjects within the Vaccine Safety Datalink (VSD database who were Health Maintenance Organization (HMO-enrolled from birth until diagnosed with an International Classification of Disease, 9th revision (ICD-9 outcome of PDD (299.xx, n=84, CP (343.xx, n=300, or MR (317.xx, 318.xx, or 319.xx, n=51.Results: Subjects with PDD had significantly (p<0.01 increased: male/female ratio (PDD=5.5 vs CP=1.5 or MR=1.3, mean age of initial diagnosis in years (PDD=3.13 vs CP=1.09 or MR=1.62, mean gestational age in weeks at birth (PDD=38.73 vs CP=36.20 or MR=34.84, mean birth weight in grams (PDD=3,368 vs CP=2,767 or MR=2,406, and mean Appearance-Pulse-Grimace-Activity-Respiration (APGAR scores at 1 minute (PDD=7.82 vs CP=6.37 or MR=6.76 and 5 minutes (PDD=8.77 vs CP=7.92 or MR=8.04, as compared to subjects diagnosed with CP or MR.Conclusion: This study suggests diagnostic substitution cannot fully explain increased PDD prevalence during the 1990s within the United States.

  4. Post-Secondary Education Attainment in Canada and the United States in the 1990s. Technical Paper Series. T-02-2E

    Science.gov (United States)

    Bowlby, Jeffrey W.

    2002-01-01

    With the North American Free Trade Agreement and today's knowledge-based economy, there is a premium placed on post-secondary education and the need to retain graduates in Canada. The share of graduates in the Canadian and the United States labour pools are key to competitiveness. This paper examines Canada's performance relative to the U.S. in…

  5. An analysis of the outdoor recreation and wilderness situation in the United States, 1989-2040: A technical document supporting the 1989 USDA Forest Service RPA Assessment

    Science.gov (United States)

    H. Ken Cordell; John C. Bergstrom; Lawrence A. Hartmann; Donald B. K. English

    1990-01-01

    The Analysis of the Outdoor Recreation and Wilderness Situation in the United States is intended to build upon past studies and to establish a new and better information base on outdoor recreation and wilderness demand and supply. Also, this assessment answers several key questions which will help identify ways to meet demand through the year 2040. Specifically, it is...

  6. The strategy for improving water-quality monitoring in the United States; final report of the Intergovernmental Task Force on Monitoring Water Quality; technical appendices

    Science.gov (United States)

    ,

    1995-01-01

    The Intergovernmental Task Force on Monitoring Water Quality (ITFM) prepared this report in collaboration with representatives of all levels of government and the private sector. The report recommends a strategy for nationwide water-quality monitoring and technical monitoring improvements to support sound water-quality decisionmaking. The strategy is intended to achieve a better return on public and private investments in monitoring, environmental protection, and natural resources management. It is also designed to expand the base of information useful to a variety of users at multiple geographic scales. Institutional and technical changes are needed to improve water-quality monitoring and to meet the full range of monitoring requirements. Monitoring must be incorporated as a critical element of program planning, implementation, and evaluation. The strategy includes recommendations in many key elements, such as the development of goal-oriented monitoring and indicators, institutional collaboration, and methods comparability. Initial actions have been taken to implement the strategy. Several Federal agencies have jointly purchased and shared remotely sensed land-cover information needed for water assessment. Major agency data systems are using common data-element names and reference tables that will ensure easy sharing of data. A number of States have held meetings with collectors of water information to initiate statewide monitoring strategies. New monitoring guidance has been developed for Federal water-quality grants to States. Many State offices have changed monitoring programs to place emphasis on priority watersheds and to improve assessment of water quality. As the competition increases for adequate supplies of clean water, concerns about public health and the environment escalate, and more demands are placed on the water information infrastructure. To meet these demands, the collaborative approach has already produced benefits, which will continue to grow as

  7. Imagining Technicities

    DEFF Research Database (Denmark)

    Liboriussen, Bjarke; Plesner, Ursula

    2011-01-01

    The actors of the building industry have access to a range of Information and Communication Technologies (ICTs), and are constantly presented with new software and new communications platforms. Through case studies, and inspired by sociotechnical approaches to the study of emerging technologies......, this article focuses on innovative uses of virtual worlds in architecture. We interviewed architects, industrial designers and other practitioners. Conceptually supported by an understanding of technicity found in Cultural Studies, the interviews were then coded with a focus on interviewees’ references...... to the elements of taste and skill. In the final analysis those references were synthesized as five imagined technicities: the architect, the engineer, the client, the Chinese, and the Virtual World native. Because technicities are often assumed and rarely discussed as actants who influence practice, their role...

  8. Imagining Technicities

    DEFF Research Database (Denmark)

    Liboriussen, Bjarke; Plesner, Ursula

    2011-01-01

    , this article focuses on innovative uses of virtual worlds in architecture. We interviewed architects, industrial designers and other practitioners. Conceptually supported by an understanding of technicity found in Cultural Studies, the interviews were then coded with a focus on interviewees’ references......The actors of the building industry have access to a range of Information and Communication Technologies (ICTs), and are constantly presented with new software and new communications platforms. Through case studies, and inspired by sociotechnical approaches to the study of emerging technologies...... to the elements of taste and skill. In the final analysis those references were synthesized as five imagined technicities: the architect, the engineer, the client, the Chinese, and the Virtual World native. Because technicities are often assumed and rarely discussed as actants who influence practice, their role...

  9. Incidence validation and relationship analysis of producer-recorded health event data from on-farm computer systems in the United States

    Science.gov (United States)

    The principal objective of this study was to analyze the credibility of health data recorded through on-farm recording systems throughout the US and the relationships between health events on a large scale. Substantial progress has been made in the genetic improvement of production traits while hea...

  10. Critical appraisal of technical problems with robotic urological surgery.

    Science.gov (United States)

    Nayyar, Rishi; Gupta, Narmada P

    2010-06-01

    To record the technical problems and complications associated with the use of da Vinci S robotic system (Intuitive Surgical, Sunnyvale, CA, USA) and to review previous reports. We analysed our records for all machine- or instrument-related errors during the course of 340 consecutive robot-assisted urological operations at our centre from July 2006 to March 2009, using one robotic machine. The cause of the error (machine or human), troubleshooting methods and consequences of the errors were evaluated. The overall device failure rate was 10.9% (37/340). The most frequent technical problems were related to robotic instruments (23/37). Other failures included colour/hue changes in the console image, intermittent double vision, fused illuminator bulb and problems with the master tool-manipulator device (hand-piece unit), patient cart circuitry, patient-side manipulator arm, closed-circuit camera unit or camera cable. Of 37 problems, 28 (76%) were surmountable during the course of surgery. The overall conversions to standard open/laparoscopic procedure attributable to mechanical failures of the robot were 0.6% (2/340). There were no complications or direct harm to the patient in any case. Most faults could be corrected or bypassed with some addition to operating room time. Despite an association of various types of new technical problems with robotic surgery, it provides a safe mode of minimally invasive surgery with very low conversion rates attributable to it, and no direct patient injury.

  11. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball

    2010-01-01

    Operational Experience At the end of the first full-year running period of LHC, CMS is established as a reliable, robust and mature experiment. In particular common systems and infrastructure faults accounted for <0.6 % CMS downtime during LHC pp physics. Technical operation throughout the entire year was rather smooth, the main faults requiring UXC access being sub-detector power systems and rack-cooling turbines. All such problems were corrected during scheduled technical stops, in the shadow of tunnel access needed by the LHC, or in negotiated accesses or access extensions. Nevertheless, the number of necessary accesses to the UXC averaged more than one per week and the technical stops were inevitably packed with work packages, typically 30 being executed within a few days, placing a high load on the coordination and area management teams. It is an appropriate moment for CMS Technical Coordination to thank all those in many CERN departments and in the Collaboration, who were involved in CMS techni...

  12. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball

    2010-01-01

    Operational Experience Since the closure of the detector in February, the technical operation of CMS has been quite smooth and reliable. Some minor interventions in UXC were required to cure failures of power supplies, fans, readout boards and rack cooling connections, but all these failures were repaired in scheduled technical stops or parasitically during access dedicated to fixing LHC technical problems. The only occasion when CMS had to request an access between fills was to search for the source of an alarm from the leak-detection cables mounted in the DT racks. After a few minutes of diagnostic search, a leaking air-purge was found. Replacement was complete within 2 hours. This incident demonstrated once more the value of these leak detection cables; the system will be further extended (during the end of year technical stop) to cover more racks in UXC and the floor beneath the detector. The magnet has also been operating reliably and reacted correctly to the 14s power cut on 29 May (see below). In or...

  13. Technical Training: Technical Training Seminar

    CERN Multimedia

    2004-01-01

    TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch Monday 9 February 2004 From 10:00 to 12:00 - IT Auditorium - bldg. 31, 3rd floor ANSOFT High-Frequency Seminar David Prestaux, Application Engineer, ANSOFT F-78535 BUC, France This Technical Training seminar will present two Ansoft application products: Ansoft HFSS and Ansoft Designer. Ansoft HFSS makes use of the Finite Element Method (FEM) to calculate field solutions from first principles. It can accurately predict all high-frequency behaviours such as dispersion, mode conversion, and losses due to materials and radiation. Ansoft Designer is a suite of design tools to fully integrate high-frequency, physics-based electromagnetic simulations into a seamless system-level simulation environment. Ansoft Designer uses a simple interface to give complete control over every design task, by a method allowing multiple solvers, Solver on Demand. • Introduction • Overview of the Ansoft Total solution • Ansoft HFSS 9...

  14. Superfund record of decision (EPA Region 5): Feed Materials Production Center, (USDOE), Operable Unit 1, Fernald, Hamilton and Butler Counties, OH, March 1, 1995. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    The decision document presents the selected remedial action for Operable Unit 1 of the FEMP site in Hamilton and Butler Counties, Ohio. Operable Unit 1 consists of Waste Pits 1 through 6, the Burn Pit, the Clearwell, and associated environmental media (excluding groundwater).

  15. 美国生涯与技术教育质量问责机制评析%Evaluation on Career and Technical Education Accountability in the United States

    Institute of Scientific and Technical Information of China (English)

    张宇; 徐国庆

    2015-01-01

    During the development process of Career and Technical education in the United States, many laws are proposed to make provision for vocational education quality assessment.National Assessment of Career and Technical Education for the Interim Report 2013 evaluated Perkins Act IV implementation in the United States in recent years.The report details the performance indicators and logical models of accountability evaluation system,using a variety of methods in the evaluation. There is a certain significance and value to the evaluation of vocational education quality,such as strengthen the legal binding in quality evaluation, pay attention to the quality of vocational education evaluation of scientific and normative and vocational education evaluation system in the fair value of penetration and so on.%2013年的《国家生涯与技术教育中期评估报告》针对帕金斯法案四在美国近年来的实施情况进行评估,该报告详细制定了绩效问责评价指标体系和逻辑模型,在评价中采用多样化的研究方法。这对我国职业教育质量评价具有一定的借鉴意义和价值,如强化法律法规在质量评价中的约束力、注意职业教育质量评价的科学性和规范性以及职业教育评价体系中公平价值的渗透等。

  16. Specifications of OCLC CJK Bibliographic Records And the Adoption of CJK Records from Asia

    Institute of Scientific and Technical Information of China (English)

    AndrewH.Wang

    1994-01-01

    OCLC Online Computer Library Center, the largest library automation network in the world, links nearly 20,000 libraries in the Uaited States and 60 other countries and territories. Introducing a library automatian network of Chinese, Japanese, and Korean(CJK) characters in 1986, OCLC operates the largest CJK library network in the world in terms of the member of online CAK institutional asers. As of January 1, 1995, OCLC had 40 CJK users in the United States, Aastralia, Hong Kang and Taiwan. As of October 1, 1994, there were nearly 850, 000 unique CJK bibliographic records in the OCLC database. OCLC is interested in sharing the CJK bibliographic records, especially in loading CJK records created in Asia into the OCLC database. To this end, OCLC has entered into an agreement with the National Central Library, Taiwan; the National Library of China, and Waseda University, Japan, and is in negotiation to load the Japan-MARC records. Sharing of CJK bibliographic records between libraries in Asia and those in the United States is a complex task as the CJK records created in Asia and those created in the United States are not compatible. This paper explains the specifieatioas of the OCLC CJK records, and lists eight areas where the incompatibility exists. The following five areas of incompatibility are due to different cataloging practices: 1. AACR2; 2. name and subject authorities;3.romantzation; 4.subject headings; and 5.ctassification schemes. Three additional areas of incompatibility are technical in nature; 6.MARC format; 7.character set; and 8.internal code.

  17. 10 CFR 455.92 - State technical assistance awards.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false State technical assistance awards. 455.92 Section 455.92... OWNED BY UNITS OF LOCAL GOVERNMENT AND PUBLIC CARE INSTITUTIONS State Grants for Technical Assistance, Program Assistance, and Marketing § 455.92 State technical assistance awards. Technical assistance awards...

  18. The logic of Technical Standardisation

    DEFF Research Database (Denmark)

    Nedergaard, Peter

    In this paper technical standardisation is understood and explained in a model where economic analysis is coupled with an analysis of the political system as proposed in rational choice theory. The aim is to answer both the question why various countries (e.g. the United States versus European...... countries) let either the market or public intervention determine the mode of technical standardisation and the possible implications of these two ways of organizing technical standardisation from an economic and a political point of view. Based upon the analysis of the paper a couple of general policy...

  19. Comprehensive Energy Assessment: EE and RE Project Optimization Modeling for United States Pacific Command (USPACOM) American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance

    Energy Technology Data Exchange (ETDEWEB)

    Brigantic, Robert T.; Papatyi, Anthony F.; Perkins, Casey J.

    2010-09-30

    This report summarizes a study and corresponding model development conducted in support of the United States Pacific Command (USPACOM) as part of the Federal Energy Management Program (FEMP) American Reinvestment and Recovery Act (ARRA). This research was aimed at developing a mathematical programming framework and accompanying optimization methodology in order to simultaneously evaluate energy efficiency (EE) and renewable energy (RE) opportunities. Once developed, this research then demonstrated this methodology at a USPACOM installation - Camp H.M. Smith, Hawaii. We believe this is the first time such an integrated, joint EE and RE optimization methodology has been constructed and demonstrated.

  20. The International System of Units (SI) in Oceanography. Report of IAPSO Working Group on Symbols, Units and Nomenclature in Physical Oceanography (SUN). Unesco Technical Papers in Marine Science 45. IAPSO Publication Scientifique No. 32.

    Science.gov (United States)

    United Nations Educational, Scientific, and Cultural Organization, Paris (France). Div. of Marine Sciences.

    This report introduces oceanographers to the International System of Units (SI) in physical oceanography. The SI constitutes a universal language, designed to be understood by all scientists. It facilitates their mutual comprehension and exchange of views and results of their work. The first part of the report is devoted to physical quantities,…

  1. Record of Decision for the Final Remedial Action for the Rocky Mountain Arsenal Offpost Unit in southern Adams County, Commerce City, Colorado

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This decision document presents the selected remedial action for the Rocky Mountain Arsenal (RMA) Offpost Operable Unit (OU) in southern Adams County, east of...

  2. Cine recording ophthalmoscope

    Science.gov (United States)

    Fitzgerald, J. W.

    1972-01-01

    Camera system provides accurate photographic recording during acceleration of centrifuge and permits immediate observation of dynamic changes in retinal circulation by a closed-circuit television loop. System consists of main camera, remote control unit, and strobe power supply unit, and is used for fluorescein studies and dynamometry sequences.

  3. 1993 Department of Energy Records Management Conference

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-31

    This document consists of viewgraphs from the presentations at the conference. Topics included are: DOE records management overview, NIRMA and ARMA resources, NARA records management training, potential quality assurance records, filing systems, organizing and indexing technical records, DOE-HQ initiatives, IRM reviews, status of epidemiologic inventory, disposition of records and personal papers, inactive records storage, establishing administrative records, managing records at Hanford, electronic mail -- legal and records issues, NARA-GAO reports status, consultive selling, automated indexing, decentralized approach to scheduling at a DOE office, developing specific records management programs, storage and retrieval at Savannah River Plant, an optical disk case study, and special interest group reports.

  4. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball and W. Zeuner

    2011-01-01

    In this report we will review the main achievements of the Technical Stop and the progress of several centrally-managed projects to support CMS operation and maintenance and prepare the way for upgrades. Overview of the extended Technical Stop  The principal objectives of the extended Technical Stop affecting the detector itself were the installation of the TOTEM T1 telescopes on both ends, the readjustment of the alignment link-disk in YE-2, the replacement of the light-guide sleeves for all PMs of both HFs, and some repairs on TOTEM T2 and CASTOR. The most significant tasks were, however, concentrated on the supporting infrastructure. A detailed line-by-line leak search was performed in the C6F14 cooling system of the Tracker, followed by the installation of variable-frequency drives on the pump motors of the SS1 and SS2 tracker cooling plants to reduce pressure transients during start-up. In the electrical system, larger harmonic filters were installed in ...

  5. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball

    Overview From a technical perspective, CMS has been in “beam operation” state since 6th November. The detector is fully closed with all components operational and the magnetic field is normally at the nominal 3.8T. The UXC cavern is normally closed with the radiation veto set. Access to UXC is now only possible during downtimes of LHC. Such accesses must be carefully planned, documented and carried out in agreement with CMS Technical Coordination, Experimental Area Management, LHC programme coordination and the CCC. Material flow in and out of UXC is now strictly controlled. Access to USC remains possible at any time, although, for safety reasons, it is necessary to register with the shift crew in the control room before going down.It is obligatory for all material leaving UXC to pass through the underground buffer zone for RP scanning, database entry and appropriate labeling for traceability. Technical coordination (notably Stephane Bally and Christoph Schaefer), the shift crew and run ...

  6. Records Management

    Data.gov (United States)

    U.S. Environmental Protection Agency — All Federal Agencies are required to prescribe an appropriate records maintenance program so that complete records are filed or otherwise preserved, records can be...

  7. Technical evaluation report, TMI action NUREG-0737 (II.D.1), relief and safety valve testing, Comanche Peak, Unit 2, Docket No. 50-446

    Energy Technology Data Exchange (ETDEWEB)

    Fineman, C.P.

    1993-01-01

    In the past, safety and relief valves installed in the primary coolant system of light water reactors have performed improperly. As a result, the authors of NUREG-0578 (TMI-2 Lessons Learned Task Force Status Report and Short-Term Recommendations) and, subsequently, NUREG-0737 (Clarification of TMI Action Plan Requirements) recommended development and completion of programs to do two things. First, the programs should reevaluate the functional performance capabilities of pressurized water reactor safety, relief, and block valves. Second, they should verify the integrity of the pressurizer safety and relief valve piping systems for normal, transient, and accident conditions. This report documents the review of those programs by EG&G Idaho, Inc. Specifically, this report documents the review of the Comanche Peak, Unit 2, Applicant response to the requirements of NUREG-0578 and NUREG-0737. This review found the Applicant provided an acceptable response reconfirming they met General Design Criteria 14, 15, and 30 of Appendix A to 10 CFR 50 for the subject equipment.

  8. Technical transformation of the furnace in atmospheric and vacuum distillation unit%常减压加热炉技术改造

    Institute of Scientific and Technical Information of China (English)

    王向蒙

    2001-01-01

    The efficiency of the furnace in No.2 atmospheric and vacuum distillation unit of JPC refinery was low,the causes of which,such as dew point corrosion,high flue gas temperature in the convention chamber and poor performance of the thermal insulation linling etc. were analyzed.The adopted transforming measures including the application of sonic soot removing system,flue gas recovery system,fiber spray coating,rock wool spray coating and correspondent adjustment of flow scheme,as well as the analysis of the results,were presented.%介绍了金陵石化公司炼油厂二套常减压装置加热炉存在露点腐蚀、对流室排烟温度高以及炉子保温衬里效果差等问题,分析了加热炉效率较低的原因。采用声波除灰系统、烟气回收系统、纤维和岩棉喷涂及相应的流程调整等措施进行改造,并对改造效果作了分析。

  9. Archaeological investigations at a toolstone source area and temporary camp: Sample Unit 19-25, Nevada Test Site, Nye County, Nevada. Technical report No. 77

    Energy Technology Data Exchange (ETDEWEB)

    Jones, R.C.; DuBarton, A.; Edwards, S.; Pippin, L.C.; Beck, C.M.

    1993-12-31

    Archaeological investigations were initiated at Sample Unit 19--25 to retrieve information concerning settlement and subsistence data on the aboriginal hunter and gatherers in the area. Studies included collection and mapping of 35.4 acres at site 26NY1408 and excavation and mapping of 0.02 acres at site 26NY7847. Cultural resources include two rock and brush structures and associated caches and a large lithic toolstone source area and lithic artifact scatter. Temporally diagnostic artifacts indicate periodic use throughout the last 12,000 years; however dates associated with projectile points indicate most use was in the Middle and Late Archaic. Radiocarbon dates from the rock and brush structures at site 26NY7847 indicate a construction date of A.D. 1640 and repair between A.D. 1800 and 1950 for feature 1 and between A.D. 1330 and 1390 and repair at A.D. 1410 for feature 2. The dates associated with feature 2 place its construction significantly earlier than similar structures found elsewhere on Pahute Mesa. Activity areas appear to reflect temporary use of the area for procurement of available lithic and faunal resources and the manufacture of tools.

  10. Technical Training: Technical Training Seminar

    CERN Multimedia

    2004-01-01

    Tuesday 30 March TECHNICAL TRAINING SEMINAR From 9:00 to 12:00 and from 13:00 to 16:00 hrs - Council Chamber, Salle B, Salle des Pas Perdus National Instruments (NI) on Tour 2004 Claudia Jüngel, Evrem Yarkin, Joel Clerc, Hervé Baour / NATIONAL INSTRUMENTS The special event NI on Tour 2004, run in Germany, Austria and Switzerland, will be at CERN on March 30. Technical seminars and free introductory courses will be offered all day long in the Council Chamber, Salle B, and Salle des Pas Perdus (buildings 61 and 503). Technical conferences: 09:00 - 12:00 Data acquisition systems on PCs. Industrial measurement and control techniques. 13:00 - 16:00 Advanced LabVIEW software and PXI instrumentation. Measuring instruments and system components for teststand automation. Introductory courses: 09:00 - 12:00 DIAdem: Data analysis and presentation 13:00 - 16:00 Data acquisition with LabVIEW Language: English and French Free special seminar. Registration is recommended with National Instruments Swi...

  11. Technical Training: Technical Training Seminar

    CERN Multimedia

    2004-01-01

    Tuesday 30 March TECHNICAL TRAINING SEMINAR From 9:00 to 12:00 and from 13:00 to 16:00 hrs - Council Chamber, Salle B, Salle des Pas Perdus National Instruments (NI) on Tour 2004 Claudia Jüngel, Evrem Yarkin, Joel Clerc, Hervé Baour / NATIONAL INSTRUMENTS The special event NI on Tour 2004, run in Germany, Austria and Switzerland, will be at CERN on March 30. Technical seminars and free introductory courses will be offered all day long in the Council Chamber, Salle B, and Salle des Pas Perdus (buildings 61 and 503). Technical conferences: 09:00 - 12:00 Data acquisition systems on PCs. Industrial measurement and control techniques. 13:00 - 16:00 Advanced LabVIEW software and PXI instrumentation. Measuring instruments and system components for teststand automation. Introductory courses: 09:00 - 12:00 DIAdem: Data analysis and presentation 13:00 - 16:00 Data acquisition with LabVIEW Language: English and French Free special seminar. Registration is recommended with National Instruments Switzerland (please sp...

  12. The National Deep-Sea Coral and Sponge Database: A Comprehensive Resource for United States Deep-Sea Coral and Sponge Records

    Science.gov (United States)

    Dornback, M.; Hourigan, T.; Etnoyer, P.; McGuinn, R.; Cross, S. L.

    2014-12-01

    Research on deep-sea corals has expanded rapidly over the last two decades, as scientists began to realize their value as long-lived structural components of high biodiversity habitats and archives of environmental information. The NOAA Deep Sea Coral Research and Technology Program's National Database for Deep-Sea Corals and Sponges is a comprehensive resource for georeferenced data on these organisms in U.S. waters. The National Database currently includes more than 220,000 deep-sea coral records representing approximately 880 unique species. Database records from museum archives, commercial and scientific bycatch, and from journal publications provide baseline information with relatively coarse spatial resolution dating back as far as 1842. These data are complemented by modern, in-situ submersible observations with high spatial resolution, from surveys conducted by NOAA and NOAA partners. Management of high volumes of modern high-resolution observational data can be challenging. NOAA is working with our data partners to incorporate this occurrence data into the National Database, along with images and associated information related to geoposition, time, biology, taxonomy, environment, provenance, and accuracy. NOAA is also working to link associated datasets collected by our program's research, to properly archive them to the NOAA National Data Centers, to build a robust metadata record, and to establish a standard protocol to simplify the process. Access to the National Database is provided through an online mapping portal. The map displays point based records from the database. Records can be refined by taxon, region, time, and depth. The queries and extent used to view the map can also be used to download subsets of the database. The database, map, and website is already in use by NOAA, regional fishery management councils, and regional ocean planning bodies, but we envision it as a model that can expand to accommodate data on a global scale.

  13. Technical analysis and individual investors

    NARCIS (Netherlands)

    Hoffmann, A.O.I.; Shefrin, H.

    2014-01-01

    We find that individual investors who use technical analysis and trade options frequently make poor portfolio decisions, resulting in dramatically lower returns than other investors. The data on which this claim is based consists of transaction records and matched survey responses of a sample of

  14. Technical analysis and individual investors

    NARCIS (Netherlands)

    Hoffmann, A.O.I.; Shefrin, H.

    2014-01-01

    We find that individual investors who use technical analysis and trade options frequently make poor portfolio decisions, resulting in dramatically lower returns than other investors. The data on which this claim is based consists of transaction records and matched survey responses of a sample of Dut

  15. Technical analysis and individual investors

    NARCIS (Netherlands)

    Hoffmann, A.O.I.; Shefrin, H.

    2014-01-01

    We find that individual investors who use technical analysis and trade options frequently make poor portfolio decisions, resulting in dramatically lower returns than other investors. The data on which this claim is based consists of transaction records and matched survey responses of a sample of Dut

  16. Disseminating Service Registry Records

    OpenAIRE

    A. Apps

    2006-01-01

    The JISC Information Environment Service Registry (IESR) contains descriptions of collections of resources available to researchers, learners and teachers in the UK, along with technical service access details. This paper describes the data model and metadata description schema of IESR, and the services IESR provides to disseminate its records. There is a particular focus on the Open Archives Initiative Protocol for Metadata Harvesting (OAI-PMH) interface, including a possible use scenario. I...

  17. Ian Taylor MBE MP Chairman Parliamentary and Scientific Committee, United Kingdom (second from left) with (from left to right) CMS Technical Coordinator A. Ball, CMS Spokesperson Tejinder (Jim) Virdee and Adviser to the Director-General J. Ellis on 2 November 2009.

    CERN Multimedia

    Maximilien Brice; CMS

    2009-01-01

    Ian Taylor MBE MP Chairman Parliamentary and Scientific Committee, United Kingdom (second from left) with (from left to right) CMS Technical Coordinator A. Ball, CMS Spokesperson Tejinder (Jim) Virdee and Adviser to the Director-General J. Ellis on 2 November 2009.

  18. 3 July 2007 - Ambassador A. Navarro Llanos, Permanent Representative of the Republic of Bolivia to the United Nations Office and other international organisations in Geneva signing a Co-operation Agreement concerning Scientific and Technical Co-operation in High-Energy Physics with CERN Director General R. Aymar.

    CERN Multimedia

    Maximilien Brice

    2007-01-01

    3 July 2007 - Ambassador A. Navarro Llanos, Permanent Representative of the Republic of Bolivia to the United Nations Office and other international organisations in Geneva signing a Co-operation Agreement concerning Scientific and Technical Co-operation in High-Energy Physics with CERN Director General R. Aymar.

  19. 21 January 2008 - Vice-President of the Human Rights Commission Z. Muhsin Al Hussein, Ambassador to United Nations A. Attar and their delegation from Saudi Arabia, visiting the ATLAS experimental cavern with Collaboration Spokesperson P. Jenni and Technical Coordinator M. Nessi.

    CERN Multimedia

    Claudia Marcelloni

    2008-01-01

    21 January 2008 - Vice-President of the Human Rights Commission Z. Muhsin Al Hussein, Ambassador to United Nations A. Attar and their delegation from Saudi Arabia, visiting the ATLAS experimental cavern with Collaboration Spokesperson P. Jenni and Technical Coordinator M. Nessi.

  20. TECHNICAL COORDINATION

    CERN Multimedia

    Austin Ball

    Summary of progress since last CMS week. Ten years of construction work have been completed. CMS is closed, in very close to the ideal low luminosity configuration, and performed well in the first tests with LHC beam. Behind this encouraging news is the story of a summer of intense commitment by many teams (from the collaboration and 3 CERN departments) working together, against the clock and despite many minor setbacks, to ensure that the experiment was ready to play a leading role in the excitement of September 10. Following beampipe bakeout and refill with pure neon, a magnificent effort by the ECAL group and the pt 5 technical crew made it possible to install and commission all 4 ECAL endcap Dees before the end of August. In the shadow of this activity, the barrel and forward pixel trackers and part of the beam monitoring were installed within the vac tank. The pt 5 technical teams then succeeded in safely removing the 20t installation tables and their support blocks from beneath the already installed ...

  1. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball and W. Zeuner

    2013-01-01

    For the reporting period, the CMS common systems and infrastructure worked well, without failures that caused significant data losses. One more disconnection of the magnet cold box occurred in the shadow of interruptions in data taking, caused by a series of technical faults. The recognition during 2012 that re-connection can only safely be done at around 2 T implies a minimum magnet recovery time of 12 hours and raises serious concerns about the number of ramping cycles of the magnet these incidents cause. This has triggered studies of how to make the cryo-system of the magnet more robust against failures. The proton-proton run ended just before the end-of-year CERN closure, during which CASTOR was installed on the negative end of CMS and both ZDC calorimeters were installed in TAN absorbers the LHC tunnel, in preparation for the heavy-ion run. The installation of CASTOR was an excellent “engineering test” of procedures for working in an activated environment. Despite some technical pr...

  2. Impact of changes in specificity of data recording on cause-specific injury mortality in the United States, 1999–2010

    OpenAIRE

    Hu, Guoqing; Mamady, Keita

    2014-01-01

    Background We aimed to examine changes in the specificity of data recording and assess the impact on cause-specific injury mortality during 1999–2010. Methods A longitudinal study was designed to analyze injury mortality data of 1999-2010. Mortality rates for unspecified injury and for cause-specific injury were obtained using CDC’s Web-based Injury Statistics Query and Reporting System (WISQARS™). The proportion of unspecified injury was used to measure the specificity of injury data recordi...

  3. A multi-channel low-power system-on-chip for single-unit recording and narrowband wireless transmission of neural signal.

    Science.gov (United States)

    Bonfanti, A; Ceravolo, M; Zambra, G; Gusmeroli, R; Spinelli, A S; Lacaita, A L; Angotzi, G N; Baranauskas, G; Fadiga, L

    2010-01-01

    This paper reports a multi-channel neural recording system-on-chip (SoC) with digital data compression and wireless telemetry. The circuit consists of a 16 amplifiers, an analog time division multiplexer, an 8-bit SAR AD converter, a digital signal processor (DSP) and a wireless narrowband 400-MHz binary FSK transmitter. Even though only 16 amplifiers are present in our current die version, the whole system is designed to work with 64 channels demonstrating the feasibility of a digital processing and narrowband wireless transmission of 64 neural recording channels. A digital data compression, based on the detection of action potentials and storage of correspondent waveforms, allows the use of a 1.25-Mbit/s binary FSK wireless transmission. This moderate bit-rate and a low frequency deviation, Manchester-coded modulation are crucial for exploiting a narrowband wireless link and an efficient embeddable antenna. The chip is realized in a 0.35- εm CMOS process with a power consumption of 105 εW per channel (269 εW per channel with an extended transmission range of 4 m) and an area of 3.1 × 2.7 mm(2). The transmitted signal is captured by a digital TV tuner and demodulated by a wideband phase-locked loop (PLL), and then sent to a PC via an FPGA module. The system has been tested for electrical specifications and its functionality verified in in-vivo neural recording experiments.

  4. Bibliography of Technical Reports 1992

    Science.gov (United States)

    1993-08-01

    This report should be cited as: Woods Hole Oceanoraphic Institution Technical Report WHOI-93-37. Approved for distribution Dr. / obert B. Gagosian XA...UNITED KINGDOM Library IFREMER Serials Department Centre de Brest Oregon State University Service Documentation - Publications Corvallis, OR 97331 BP 70

  5. Revised Recommendation Concerning Technical and Vocational Education.

    Science.gov (United States)

    United Nations Educational, Scientific, and Cultural Organization, Paris (France).

    The UNESCO (United Nations Education, Scientific, and Cultural Organization) revised recommendation setting forth general principles, goals, and guidelines concerning technical and vocational education (adopted by the General Conference at its 18th session in Paris, 19 November 1974) is presented under the following headings: (1) Technical and…

  6. Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Eggeman, Tim [ZeaChem Inc., Lakewood, CO (United States); O' Neill, Brian [ZeaChem Inc., Lakewood, CO (United States)

    2016-08-17

    ZeaChem Inc. and US DOE successfully demonstrated the ZeaChem process for producing sugars and ethanol from high-impact biomass feedstocks. The project was executed over a 5-year period under a $31.25 million cooperative agreement (80:20 Federal:ZeaChem cost share). The project was managed by dividing it into three budget periods. Activities during Budget Period 1 were limited to planning, permitting, and other pre-construction planning. Budget Period 2 activities included engineering, procurement, construction, commissioning, start-up and initial operations through the Independent Engineer Test Runs. The scope of construction was limited to the Chem Frac and Hydrogenolysis units, as the Core Facility was already in place. Construction was complete in December 2012, and the first cellulosic ethanol was produced in February 2013. Additional operational test runs were conducted during Budget Period 3 (completed June 2015) using hybrid poplar, corn stover, and wheat straw feedstocks, resulting in the production of cellulosic ethanol and various other biorefinery intermediates. The research adds to the understanding of the Chem Frac and Hydrogenolysis technologies in that the technical performance of each unit was measured, and the resulting data and operational experience can be used as the basis for engineering designs, thus mitigating risks for deployment in future commercial facilities. The Chem Frac unit was initially designed to be operated as two-stage dilute acid hydrolysis, with first stage conditions selected to remove the hemicellulose fraction of the feedstock, and the second stage conditions selected to remove the cellulose fraction. While the Chem Frac unit met or exceeded the design capacity of 10 ton(dry)/day, the technical effectiveness of the Chem Frac unit was below expectations in its initial two-stage dilute acid configuration. The sugars yields were low, the sugars were dilute, and the sugars had poor fermentability caused by excessive inhibitors

  7. Ozone Layer Research and Technical Resources

    Science.gov (United States)

    Access information on research and technical resources related to ozone layer science. This page provides links to research efforts led by organizations such as the National Oceanic and Atmospheric Administration, the United Nations Environment Program, an

  8. A Chronosequence Feasibility Assessment of Emergency Fire Rehabilitation Records within the Intermountain Western United States - Final Report to the Joint Fire Science Program - Project 08-S-08

    Science.gov (United States)

    Knutson, Kevin C.; Pyke, David A.; Wirth, Troy A.; Pilliod, David S.; Brooks, Matthew L.; Chambers, Jeanne C.

    2009-01-01

    Department of the Interior (DOI) bureaus have invested heavily (for example, the U.S. Bureau of Land Management (BLM) spent more than $60 million in fiscal year 2007) in seeding vegetation for emergency stabilization and burned area rehabilitation of non-forested arid lands over the past 10 years. The primary objectives of these seedings commonly are to (1) reduce the post-fire dominance of non-native annual grasses, such as cheatgrass (Bromus tectorum) and red brome (Bromus rubens); (2) minimize the probability of recurrent fire; and (3) ultimately produce desirable vegetation characteristics (for example, ability to recover following disturbance [resilience], resistance to invasive species, and a capacity to support a diverse flora and fauna). Although these projects historically have been monitored to varying extents, land managers currently lack scientific evidence to verify whether seeding arid and semiarid lands achieves desired objectives. Given the amount of resources dedicated to post-fire seeding projects, a synthesis of information determining the factors that result in successful treatments is critically needed. Although results of recently established experiments and monitoring projects eventually will provide useful insights for the future direction of emergency stabilization and burned area rehabilitation programs, a chronosequence approach evaluating emergency stabilization and burned area rehabilitation treatments (both referenced hereafter as ESR treatments) over the past 30 years could provide a comprehensive assessment of treatment success across a range of regional environmental gradients. By randomly selecting a statistically robust sample from the population of historic ESR treatments in the Intermountain West, this chronosequence approach would have inference for most ecological sites in this region. The goal of this feasibility study was to compile and examine historic ESR records from BLM field offices across the Intermountain West to

  9. Technical presentation

    CERN Multimedia

    FP Department

    2009-01-01

    07 April 2009 Technical presentation by Leuze Electronics: 14.00 – 15.00, Main Building, Room 61-1-017 (Room A) Photoelectric sensors, data identification and transmission systems, image processing systems. We at Leuze Electronics are "the sensor people": we have been specialising in optoelectronic sensors and safety technology for accident prevention for over 40 years. Our dedicated staff are all highly customer oriented. Customers of Leuze Electronics can always rely on one thing – on us! •\tFounded in 1963 •\t740 employees •\t115 MEUR turnover •\t20 subsidiaries •\t3 production facilities in southern Germany Product groups: •\tPhotoelectric sensors •\tIdentification and measurements •\tSafety devices

  10. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball and W. Zeuner

    2010-01-01

    Overview Once again, the bulk of this article reviews the intense activity of a recently completed shutdown, which, although quite unforeseeable until a few weeks before it started, proved by its success that our often advertised capability to conduct major maintenance within a two month period is real. Although safely completed, on-time to remarkable precision, the activity was not without incident, and highlighted our dependence on many experienced, specialist teams and their precise choreography. Even after the yoke was safely closed, magnet re-commissioning and beampipe pumpdown showed new and thought-provoking behaviour. The struggle to maintain adequate technical resources will be a pre-occupation over the coming months, in parallel with the start of truly sustained operation, for which various procedures are still being put in place. Planning for future shutdowns must now become a high priority, with many working groups and task forces already in existence to prepare infrastructure improvements and to...

  11. Technical presentation

    CERN Multimedia

    GS Department

    2010-01-01

    10 March 2010 DYNEOS 10:00 – 12:00 - Main Building, Room B, 61-1-009 Dyneos AG is active in the fields of photonics, laser and high-precision positioning. Our highly qualified engineer team has more than 30 years of experience in electro-optical solutions sales. The engineers are supported by a technical and administrative team. We are focused on the Swiss market and represent six suppliers (Coherent, PI Physik Instrumente, SIOS, Nanonics Imaging, APE, Ekspla) in order to give a qualified sales and service support to our customers. Our products are dedicated to the research field as well as to industry. In addition to standard catalog products, we offer custom designs to fulfill the specific needs of OEM customers or specific applications.

  12. Technical presentation

    CERN Multimedia

    FI Department

    2008-01-01

    RADIOSPARES, the leading catalogue distributor of components (electronic, electrical, automation, etc.) and industrial supplies will be at CERN on Friday 3 October 2008 (Main Building, Room B, from 9.00 a.m. to 3.00 p.m.) to introduce its new 2008/2009 catalogue. This will be the opportunity for us to present our complete range of products in more detail: 400 000 part numbers available on our web site (Radiospares France, RS International, extended range of components from other manufacturers); our new services: quotations, search for products not included in the catalogue, SBP products (Small Batch Production: packaging in quantities adapted to customers’ requirements); partnership with our focus manufacturers; demonstration of the on-line purchasing tool implemented on our web site in conjunction with CERN. RADIOSPARES will be accompanied by representatives of FLUKE and TYCO ELECTRONICS, who will make presentations, demonstrate materials and answer any technical questio...

  13. INDEPENDENT TECHNICAL REVIEW OF THE FOCUSED FEASIBILITY STUDY AND PROPOSED PLAN FOR DESIGNATED SOLID WASTE MANAGEMENT UNITS CONTRIBUTING TO THE SOUTHWEST GROUNDWATER PLUME AT THE PADUCAH GASEOUS DIFFUSION PLANT

    Energy Technology Data Exchange (ETDEWEB)

    Looney, B.; Eddy-Dilek, C.; Amidon, M.; Rossabi, J.; Stewart, L.

    2011-05-31

    The U. S. Department of Energy (DOE) is currently developing a Proposed Plan (PP) for remediation of designated sources of chlorinated solvents that contribute contamination to the Southwest (SW) Groundwater Plume at the Paducah Gaseous Diffusion Plant (PGDP), in Paducah, KY. The principal contaminants in the SW Plume are trichloroethene (TCE) and other volatile organic compounds (VOCs); these industrial solvents were used and disposed in various facilities and locations at PGDP. In the SW plume area, residual TCE sources are primarily in the fine-grained sediments of the Upper Continental Recharge System (UCRS), a partially saturated zone that delivers contaminants downward into the coarse-grained Regional Gravel Aquifer (RGA). The RGA serves as the significant lateral groundwater transport pathway for the plume. In the SW Plume area, the four main contributing TCE source units are: (1) Solid Waste Management Unit (SWMU) 1 / Oil Landfarm; (2) C-720 Building TCE Northeast Spill Site (SWMU 211A); (3) C-720 Building TCE Southeast Spill Site (SWMU 211B); and (4) C-747 Contaminated Burial Yard (SWMU 4). The PP presents the Preferred Alternatives for remediation of VOCs in the UCRS at the Oil Landfarm and the C-720 Building spill sites. The basis for the PP is documented in a Focused Feasibility Study (FFS) (DOE, 2011) and a Site Investigation Report (SI) (DOE, 2007). The SW plume is currently within the boundaries of PGDP (i.e., does not extend off-site). Nonetheless, reasonable mitigation of the multiple contaminant sources contributing to the SW plume is one of the necessary components identified in the PGDP End State Vision (DOE, 2005). Because of the importance of the proposed actions DOE assembled an Independent Technical Review (ITR) team to provide input and assistance in finalizing the PP.

  14. Technical Training: Technical Training Seminar

    CERN Multimedia

    2004-01-01

    TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch Tuesday 3 February 2004 From 09:00 to 13:30 - Training Centre Auditorium - bldg. 593, room 11 USB (Universal Serial Bus) CYPRESS Seminar Claudia Colombini, Field Application Engineer CYPRESS ActiveComp Electronic GmbH D-85077 MANCHING, Germany As a pioneer in USB, CYPRESS sets the standard for cost-effective solutions without sacrificing functionality, performance or reliability. Having shipped over 200 million USB devices, Cypress is the undisputed market leader and demonstrates unmatched USB expertise. With the industry's broadest selection of USB solutions, Cypress has the right silicon, software and support for every USB application, from Low-speed to High-Speed and USB On-The-Go (OTG). 9:00 - 10:30 Overview of USB systems. USB CYPRESS product overview. Peripherals: Low Speed, Full Speed, High Speed (1.1 and 2.0). Hub Solutions, Embedded Host Solutions, On-The-Go (OTG) and wireless USB. USB Development Tools (first part) 10:30 -...

  15. An Exploration into Juvenile Records Sealed in the United States%美国未成年人前科记录封存探析

    Institute of Scientific and Technical Information of China (English)

    张鸿巍

    2014-01-01

    自少年法院创设伊始,美国少年司法长期秉承保密性原则而对未成年人前科记录予以封存,以避免给未成年人带来污名化后果。然而,随着各州未成年人前科记录封存呈松动趋势,部分原先严格保密并限制公布于众的前科记录,除了可向执法及司法部门开放外,亦可在一定条件下向被害人、学校及媒体开放。与此同时,依移送法律而从少年法院移送至刑事(成人)法院的未成年人,其先前少年法院记录亦可作为后者加重刑罚的考量因素之一。%Since the creation of the juvenile court, American juvenile justice has long adhered to the principle of confidentiality and therefore keeps juvenile records sealed in order to avoid stigmatization of the minors. However, the principle that was strictly followed has become loose in many states. Some of the juvenile records that were previously kept strictly confidential and restricted to the public, have gradually opened to the victims, schools and the media, in addition to opening to law enforcement and judiciary. Meanwhile, if a juvenile offender is transferred to the criminal (adult) court, his or her previous juvenile court record may also serve as an aggravating factor for sentencing in the criminal court.

  16. 《预制组合立管技术规范》GB50682-2011编制与介绍%Compilation and Introduction of Technical Code for Pre.fabricated United Pipe Risers GB50682-2011

    Institute of Scientific and Technical Information of China (English)

    张杰; 叶永杨; 尹奎; 蒋隆

    2011-01-01

    高层建筑高度高,管井管道密集,传统管井技术已不能满足管线布置要求.住房和城乡建设部建标[ 2009]88号文件将《预制组合立管技术规范》GB50682-2011列入国家规范编制计划,由中建三局第一建设工程有限责任公司、同济大学等单位编制,将于2012年1月1日实施.介绍了规范编制思路与主要内容,指出预制组合立管技术的适用条件、预制组合立管的设计原则与方法、预制组合立管设计的荷载计算、预制组合立管管道与其支架的制作和安装工艺,以及预制立管试验与验收方法等.该规范独创了密集立管与主体结构同步安装的施工体系,可加快施工速度、降低管井作业风险、提高工程质量.%The traditional pipe riser technology can not meet requirements of pipelines arrangement of tall buildings because of the large height and dense pipelines. According to the file of No. [2009] 88 from the Ministry of Housing and Urban-rural Development, the National Code of Technical Code for Pre-fabricated ?United Pipe Risers GB50682-2011 is compiled by the First Construction Limited Company of China Construction Third Engineering Bureau, Tongji University and some other related companies. It will implement on January 1, 2012. The compiling thinking and main contents of the code are introduced such as applicable conditions, design principle, loads calculation of pre-fabricated united pipe risers, fabrication and assembly of the pipe and support frame, as well as test and acceptance of pre-fabricated unit pipes. The code originally created synchronizing assembly of dense pipes and main structure to shorten the construction time, lower work risks and improve project quality.

  17. ENERGY STAR Unit Reports

    Data.gov (United States)

    Department of Housing and Urban Development — These quarterly Federal Fiscal Year performance reports track the ENERGY STAR qualified HOME units that Participating Jurisdictions record in HUD's Integrated...

  18. Optical sedimentation recorder

    Science.gov (United States)

    Bishop, James K.B.

    2014-05-06

    A robotic optical sedimentation recorder is described for the recordation of carbon flux in the oceans wherein both POC and PIC particles are captured at the open end of a submersible sampling platform, the captured particles allowed to drift down onto a collection plate where they can be imaged over time. The particles are imaged using three separate light sources, activated in sequence, one source being a back light, a second source being a side light to provide dark field illumination, and a third source comprising a cross polarized light source to illuminate birefringent particles. The recorder in one embodiment is attached to a buoyancy unit which is capable upon command for bringing the sedimentation recorder to a programmed depth below the ocean surface during recordation mode, and on command returning the unit to the ocean surface for transmission of recorded data and receipt of new instructions. The combined unit is provided with its own power source and is designed to operate autonomously in the ocean for extended periods of time.

  19. United States Navy - Canadian forces solid state flight data recorder/crash position locator experiment on the B-720 controlled impact demonstration

    Science.gov (United States)

    Watters, D. M.

    1986-01-01

    The operation of a radio beacon position locator during and after the remotely controlled transport aircraft is discussed. The radio beacon transmission was actuated and was picked up by the Navy P-3A chase aircraft for a short time, after which reception was lost. The pilot reported that he received a signal on both 121.5 MHz and 243 MHz for a period of approximately 5 seconds. Five minutes after the crash a portable direction finding unit located on the roof of the NASA Dryden Flight Research Facility, 4 miles distant from the crash, was unable to pick up the beacon transmission. The fire crews started fighting the fires approximately 90 seconds after the time of impact. Navy personnel access to the crash site was allowed on the morning of December 2, 1984. Radio beacon locator was found resting top side up, 15 feet forward and 13 feet perpendicular from the tray location the starboard side of the aircraft. An immediate inspection indicated the airfoil suffered moderate fire damage with paint peeling but not intumescing. The visual marker strobe lamp housings were intact but extensively burned such that it was impossible to see if the lamps had survived. The airfoil suffered minor structural damage, with assorted dents, etc. The extended plunger on the ARU-21 release unit indicated that the pyrotechnic deployment system operated. The radio beacon base (tray) suffered some heat and fire damage, and was charred and blackened by smoke. The frangible switch in the nose survived and the switch in the belly was recovered and found to have actuated. It is assumed that this switch fired the ARU-21 squib. There were no other release switches installed in the normally open system in the aircraft.

  20. Turbidite Megabeds in an Oceanic Rift Valley Recording Jökulhlaups of Late Pleistocene Glacial Lakes of the Western United States.

    Science.gov (United States)

    Zuffa; Normark; Serra; Brunner

    2000-05-01

    Escanaba Trough is the southernmost segment of the Gorda Ridge and is filled by sandy turbidites locally exceeding 500 m in thickness. New results from Ocean Drilling Program (ODP) Sites 1037 and 1038 that include accelerator mass spectrometry (AMS) 14C dates and revised petrographic evaluation of the sediment provenance, combined with high-resolution seismic-reflection profiles, provide a lithostratigraphic framework for the turbidite deposits. Three fining-upward units of sandy turbidites from the upper 365 m at ODP Site 1037 can be correlated with sediment recovered at ODP Site 1038 and Deep Sea Drilling Program (DSDP) Site 35. Six AMS 14C ages in the upper 317 m of the sequence at Site 1037 indicate that average deposition rates exceeded 10 m/k.yr. between 32 and 11 ka, with nearly instantaneous deposition of one approximately 60-m interval of sand. Petrography of the sand beds is consistent with a Columbia River source for the entire sedimentary sequence in Escanaba Trough. High-resolution acoustic stratigraphy shows that the turbidites in the upper 60 m at Site 1037 provide a characteristic sequence of key reflectors that occurs across the floor of the entire Escanaba Trough. Recent mapping of turbidite systems in the northeast Pacific Ocean suggests that the turbidity currents reached the Escanaba Trough along an 1100-km-long pathway from the Columbia River to the west flank of the Gorda Ridge. The age of the upper fining-upward unit of sandy turbidites appears to correspond to the latest Wisconsinan outburst of glacial Lake Missoula. Many of the outbursts, or jökulhlaups, from the glacial lakes probably continued flowing as hyperpycnally generated turbidity currents on entering the sea at the mouth of the Columbia River.

  1. TECHNICAL COORDINATION

    CERN Multimedia

    Austin Ball

    2013-01-01

      Since the last report, much visible progress has been made, as the LS1 programme approaches the halfway point. From early October, technical and safety shift-crew have been present around the clock, allowing detectors to stay switched on overnight, ensuring that safety systems are operational and instructions for non-expert shift-crew are clear. LS1 progress Throughout the summer, whilst the solenoid vacuum tank and YB0 surfaces were accessible, an extensive installation programme took place to prepare for Tracker colder operation and the PLT installation, in 2014, the Phase 1 Pixel Tracker installation, in 2016–’17, and the HCAL Phase 1 upgrade completion, ending in LS2. This included pipework for N2 or dry air to flush the Tracker bulkhead region, many sensors to monitor temperature and dew point in the Tracker and its service channels, heating wires outside the Tracker cooling bundles, supports for the new vacuum-jacketed, concentric, CO2 Pixel cooling lines, the PLT cool...

  2. 77 FR 30558 - Records Schedules; Availability and Request for Comments

    Science.gov (United States)

    2012-05-23

    ..., this public notice lists the organizational unit(s) accumulating the records or indicates agency- wide.... Included are beryllium exposure records, all other exposure records, and supporting documentation. 19...

  3. Technical feasibility study of Voltage Optimization Unit

    DEFF Research Database (Denmark)

    Hu, Junjie; Marinelli, Mattia; Coppo, Massimiliano

    transformer with OLTC per phase is necessary and valuable. The main conclusion is that power distribution transformer with OLTC control on each phase can significantly improve the PV hosting capacity in the analyzed unbal-anced scenarios. To investigate the verification problem, a simulation study...... is performed using the soft-wares DigSilent PowerFactory and Matlab. In this simulation study, a real low voltage network from Dong Eldistribution is modeled in Powerfactory. The measured data of the real low voltage network is analyzed and the resulting loading profiles including active and reactive power...... are used as load basics for the analysis. In term of PV genera-tion profiles, a realistic PV output power is assumed. Four relevant indicies such as phase neutral voltage, netural potential voltage, unbalanced factor (VUF), and power losses are evaluated in the present study. The simulation tests include...

  4. Development framework for a patient-centered record.

    Science.gov (United States)

    Puentes, John; Roux, Michèle; Montagner, Julien; Lecornu, Laurent

    2012-12-01

    Patient records have been developed to support the physician-oriented medical activity scheme. One recommended yet rarely studied alternative, expected to improve healthcare, is the patient-centered record. We propose a development framework for such record, which includes domain-specific database models at the conceptual level, analyzing the fundamental role of complementary information destined to ensure proper patient understanding of related clinical situations. A patient-centered awareness field study of user requirements and medical workflow was carried out in three medical services and two technical units to identify the most relevant elements of the framework, and compared to the definitions of a theoretical approach. Three core data models - centered on the patient, medical personnel, and complementary patient information, corresponding to the determined set of entities, information exchanges and actors roles, constitute the technical recommendations of the development framework. An open source proof of concept prototype was developed to show the model feasibility. The resulting patient-centered record development framework implies particular medical personnel contributions to supply complementary information.

  5. Forest cover change in the upper Midwestern United States results from both climate and land use change following European settlement: Historical survey and weather records provide robust support for modeling applications

    Science.gov (United States)

    Goring, S. J.; Williams, J. W.; McLachlan, J. S.; Dawson, A.; Dietze, M.; Paciorek, C. J.; Mladenoff, D. J.; Record, S.; Cogbill, C. V.; Hooten, M.; Ruid, M.; Jackson, S. T.

    2013-12-01

    Since European settlement, both climate and human land use have acted on forests in the upper Midwestern United States resulting in changes in forest structure and composition. The extent of these changes has been examined locally and at the state level by examining forest records from the Public Lands Survey System (PLSS), but here we bring together records of changing forest composition with weather records from the mid to late 19th century from the 19th Century Forts and Observer's Database. We are able to assign attribution for taxon range and composition shifts in the region to either land use, climate or both. We see that much of the range contraction in the region seen when comparing Forest Inventory and Analysis data with Public Land Survey System data occurs along the prairie margin, with northern forests showing greater stability in both range and composition suggesting a dominant role for land use in structuring regional vegetation. Modern forests are often less diverse than PLSS forests and the mean minimum dissimilarity between modern and PLSS-era forests is significantly higher than the minimum dissimilarity within either the PLSS-era forests or the modern (FIA) forests, indicating the possiblity that our modern forests have already become 'no-analogue' ecosystems.

  6. Engineering Technical Support Center Annual Report Fiscal Year 2015

    Science.gov (United States)

    The United States Environmental Protection Agency (EPA or Agency) Office of Research and Development (ORD) created the Engineering Technical Support Center (ETSC) in 1987, one of several technical support centers created as part of the Technical Support Project (TSP). ETSC provid...

  7. Engineering Technical Support Center Annual Report Fiscal Year 2015

    Science.gov (United States)

    The United States Environmental Protection Agency (EPA or Agency) Office of Research and Development (ORD) created the Engineering Technical Support Center (ETSC) in 1987, one of several technical support centers created as part of the Technical Support Project (TSP). ETSC provid...

  8. Tracing Graduates through Reunion Parties: Secondary Technical Education in Mozambique.

    Science.gov (United States)

    Ziderman, Adrian

    1997-01-01

    A review of enrollments, graduates, and costs for Mozambique secondary technical schools and the results of a follow-up employment survey conducted at graduate reunion parties indicate low internal and external efficiency and high unit costs in the technical education system, particularly "basic" technical schools. Three possible types…

  9. Certified records manager exam

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    The Institute of Certified Records Managers (ICRM) is a non-profit, certifying organization of professional records managers and administrators. ICRM members are experienced in information requirements, records and information systems, and the related office systems and technologies. All members have met certification requirements and have received the Certified Records Manager (CRM) designation. As the field of information and records management moves toward standardization, and as the application of new technologies and technicalities complicate the measurement and demonstration of professional competence, the need for a means of identifying persons who have basic competency increases. The ICRM is providing such a means by testing and certifying basic knowledge. More and more job announcements are requiring this evidence of competency. Unfortunately, as an organization, NIRMA has a relatively small number of CRMs. The goal of the ICRM Development Group is two-fold; (1) to encourage NIRMA members to obtain their certification by providing basic information and support and; (2) to develop the Nuclear Specialist test module which will demonstrate that bearers have demonstrated expertise in nuclear records management as well as basic competencies. This report covers the examination process.

  10. Implementation of the Nutrition Care Process and International Dietetics and Nutrition Terminology in a single-center hemodialysis unit: comparing paper vs electronic records.

    Science.gov (United States)

    Rossi, Megan; Campbell, Katrina Louise; Ferguson, Maree

    2014-01-01

    There is little doubt surrounding the benefits of the Nutrition Care Process and International Dietetics and Nutrition Terminology (IDNT) to dietetics practice; however, evidence to support the most efficient method of incorporating these into practice is lacking. The main objective of our study was to compare the efficiency and effectiveness of an electronic and a manual paper-based system for capturing the Nutrition Care Process and IDNT in a single in-center hemodialysis unit. A cohort of 56 adult patients receiving maintenance hemodialysis were followed for 12 months. During the first 6 months, patients received the usual standard care, with documentation via a manual paper-based system. During the following 6-month period (Months 7 to 12), nutrition care was documented by an electronic system. Workload efficiency, number of IDNT codes used related to nutrition-related diagnoses, interventions, monitoring and evaluation using IDNT, nutritional status using the scored Patient-Generated Subjective Global Assessment Tool of Quality of Life were the main outcome measures. Compared with paper-based documentation of nutrition care, our study demonstrated that an electronic system improved the efficiency of total time spent by the dietitian by 13 minutes per consultation. There were also a greater number of nutrition-related diagnoses resolved using the electronic system compared with the paper-based documentation (PDietetics. Published by Elsevier Inc. All rights reserved.

  11. Attitude influence on performance in technical skill acquisition among formal technical trainees

    Directory of Open Access Journals (Sweden)

    Adinife Patrick Azodo

    2014-08-01

    Full Text Available This cross-sectional study analyzed attitude influence on performance in technical skill involved in a specific trade chosen among all the formal technical trainees of Don Bosco Technical Institute (DBTI, Onitsha, Nigeria. This study was carried out between May and July, 2013. The 24-item questionnaire, designed after critical examination and revision of some related studies and a combination of individual technical projects, sequence of job operation prepared by the students and written tests which cumulatively made up the school academic performance record in technical work were used to assess students’ attitude and performance respectively. Analysis of the data showed that majority of the students have positive attitudes towards technical skill involved in technical education. There is also positive relationships between students’ attitude in technical skill acquisition and their performance. This was evident from the overall attitude and performance mean scores of 4.3333 and 69.8376 representing 86.67% and 69.84% respectively. Pearson correlation coefficient (r of relationship between attitude and performance in technical skill involved in technical education gave an ‘r’ value of 0.366 which was a positive correlation. However, the good performance and knowledge of the usefulness of technical skills in life did not stimulate the students to continue their careers in a related technical profession. This demands serious attention.

  12. 44 CFR 6.6 - Safeguarding systems of records.

    Science.gov (United States)

    2010-10-01

    ... systems of records. (a) Systems managers shall ensure that appropriate administrative, technical, and..., training, special qualification, and skills, performance appraisals, and conduct, shall be stored in a...

  13. DOE technical standards list. Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listing of current DOE technical standards, non-Government standards that have been adopted by DOE, other Government documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  14. Development of technical solutions on a coal-fired boiler for a power plant unit of 800 MW with steam parameters of 35 MPa and 700/720°C

    Science.gov (United States)

    Shvarts, A. L.; Verbovetsky, E. Kh.; Somova, E. V.; Smolin, A. V.

    2015-12-01

    Development of a coal-fired boiler for a power plant unit of 800 MW with advanced ultra-supercritical steam parameters of 35 MPa and 700/720°C is presented. The main technical solutions providing the reliability, profitability, and low emissions of harmful substances in the atmosphere are given. The fuel is the black coal of (Taldinskoye field, Kuznetsk basin). The gross efficiency of the boiler is 94%. The U-shaped configuration of a boiler is chosen, which allows the reduction of the capital expenditure for steam turbine piping made of expensive nickel alloys. The horizontal connection flue of the boiler, where the primary and reheat steam screens are located, is equipped with two cold funnels. The upper section of the convection shaft is separated with a vertical screen wall into two parallel "split tail" flues, which allows one to control the reheat steam temperature by redistributing the flue gas between the gas flues. The URS screens are two-stage with a lifting motion of the medium and a partial bypassing of the first stage. The lower radiant section is two-stage. To reduce the temperature of screen walls at the fire chamber outlet, the lowering motion of the working medium and combustion gases is used. The hydrodynamics of the screens with the lowering motion of the medium for preventing the aperiodic instability in the start regimes is analyzed. Besides the stepwise combustion of coal dust providing the improved environmental parameters, the boiler plant is equipped with a selective catalytic reduction (SCR) system, an ash collector (an electric filter combined with a filter bag), and a desulphurization device.

  15. Robert Recorde

    CERN Document Server

    Williams, Jack

    2011-01-01

    The 16th-Century intellectual Robert Recorde is chiefly remembered for introducing the equals sign into algebra, yet the greater significance and broader scope of his work is often overlooked. This book presents an authoritative and in-depth analysis of the man, his achievements and his historical importance. This scholarly yet accessible work examines the latest evidence on all aspects of Recorde's life, throwing new light on a character deserving of greater recognition. Topics and features: presents a concise chronology of Recorde's life; examines his published works; describes Recorde's pro

  16. PESTICIDE APPLICATION TECHNICS IMPROVEMENT

    Directory of Open Access Journals (Sweden)

    Đuro Banaj

    2011-06-01

    Full Text Available The academic textbook Pesticide application tehnics improvement is the result of several-year recording theoretical models, numerous practical tests, and data collection relating to technical systems in plant protection and its environment in the narrowest sense. In this first edition, the authors cover the area they have dealt with for many years. The authors aimed to present complete and clear methods how to solve specific problems in the agricultural practice management, plant protection, and direct practice application – ‘‘Know- How'', with as many as possible useful data. References used, along with local ones, are mostly American and from Western Europe. This textbook is intended for those who already use the agricultural technique in plant protection and those who are just acquiring the basics of technical systems proper application in daily practice, regardless the size of the agricultural farm. The authors covered in details and explained some bases of physics logic, analysis, and synthesis of specific laws while using pesticides due to extremely importance in understanding the problem area.

  17. Barriers to Electronic Health Record Adoption: a Systematic Literature Review.

    Science.gov (United States)

    Kruse, Clemens Scott; Kristof, Caitlin; Jones, Beau; Mitchell, Erica; Martinez, Angelica

    2016-12-01

    Federal efforts and local initiatives to increase adoption and use of electronic health records (EHRs) continue, particularly since the enactment of the Health Information Technology for Economic and Clinical Health (HITECH) Act. Roughly one in four hospitals not adopted even a basic EHR system. A review of the barriers may help in understanding the factors deterring certain healthcare organizations from implementation. We wanted to assemble an updated and comprehensive list of adoption barriers of EHR systems in the United States. Authors searched CINAHL, MEDLINE, and Google Scholar, and accepted only articles relevant to our primary objective. Reviewers independently assessed the works highlighted by our search and selected several for review. Through multiple consensus meetings, authors tapered articles to a final selection most germane to the topic (n = 27). Each article was thoroughly examined by multiple authors in order to achieve greater validity. Authors identified 39 barriers to EHR adoption within the literature selected for the review. These barriers appeared 125 times in the literature; the most frequently mentioned barriers were regarding cost, technical concerns, technical support, and resistance to change. Despite federal and local incentives, the initial cost of adopting an EHR is a common existing barrier. The other most commonly mentioned barriers include technical support, technical concerns, and maintenance/ongoing costs. Policy makers should consider incentives that continue to reduce implementation cost, possibly aimed more directly at organizations that are known to have lower adoption rates, such as small hospitals in rural areas.

  18. Técnica de monitorado continuo (on – line para la evaluación del estado técnico de los turbogrupos de 64 y 100 MW. // Technique of continuous monitored (on - line for the evaluation of the technical state in steam turbine units of 64 and 100 MW.

    Directory of Open Access Journals (Sweden)

    F. de la Torre. Silva

    2001-04-01

    Full Text Available En este trabajo se presenta el resultado del estudio de factibilidad realizado a los turbogrupos de 64 y 100 MW de dosCentrales Termoeléctricas, sobre el empleo de técnicas de monitorado continuo “on line” para la evaluación del estadotécnico de estos turbogrupos.Palabras claves: Turbinas de vapor,vibraciones, monitorado continuo “on line”, diagnóstico.______________________________________________________________________Abstract:In this work an study of feasibility is presented. This study is carried out in steam turbine units of 64 and 100 MW, and show the use ofcontinuous monitored technique (on line for the evaluation of the technical state of these turbine units.Key Words: Steam turbines, vibrations, continuous monitoring on line, turbines supervision, Diagnosis,technical state evaluation.

  19. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball

    2011-01-01

    1 Operational experience 2011 1.1 Overview Starting on a positive note, it is encouraging that, for the period of this report, the operation of CMS and its entire infrastructure at Point 5 was remarkably stable and efficient. No luminosity was lost due to failures of common systems or infrastructure. The major faults were two failures of rack ventilation turbines, a leak in a water pump in the endcap circuit and the first fast dump of the magnet since underground commissioning. As the rack ventilation units have two turbines, these single turbine failures were tolerated until the next possible access. The water pump survived until the end of the fill after which the circuit was switched to a reserve pump (which in principle is also possible “on the fly”). A faulty position controller of a cryo-valve serving the cryo-power leads caused a spontaneous closure of the valve leading to the fast dump of the magnet. In this case, CMS was lucky once again, since the incident happened on the first ...

  20. Medical Services: Nursing Records and Reports

    Science.gov (United States)

    2007-11-02

    11) Item 11. Self–explanatory. (12) Item 12. Record if electrosurgical unit (ESU) was used by “X” in the YES or NO block. Enter medical maintenance...Guard cc cubic centimeter CNS clinical nurse specialist ESU electrosurgical unit expir expiration HR health record (records filed in DA Form 3444

  1. Use of Electronic Health Records in Residential Care Communities

    Science.gov (United States)

    ... the National Technical Information Service NCHS Use of Electronic Health Records in Residential Care Communities Recommend on ... Facilities Most residential care communities did not use electronic health records in 2010, and use varied by ...

  2. Phenological Records

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Phenology is the scientific study of periodic biological phenomena, such as flowering, breeding, and migration, in relation to climatic conditions. The few records...

  3. Technical Basis for Also Using Health-Risk Assessment to Establish Contaminant Boundaries for Corrective Action Units (CAUs) of the Underground Test Area (UGTA) at the Nevada Test Site (NTS)

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, J I; Tompson, A F

    2003-12-29

    This technical basis document serves two purposes. First, it provides a detailed discussion of the rationale and procedures suitable for deriving a risk-based contaminant boundary that will protect public health unambiguously, along with examples that are intended as illustrative only to facilitate understanding. Second, it explains the benefits of using such information as the framework for fostering risk communication to educate, inform, and enlighten, and importantly, to fully disclose the goals and structure of contaminant boundaries. To determine a contaminant boundary within a CAU, standards or criteria must be adopted that establish whether groundwater is safe or unsafe for public (and worker) use. For purposes of this discussion, drinking water consumption is considered the pathway of exposure. However, in practice, a realistic land-use scenario must be described and agreed upon before a prospective, realistic risk-based calculation is performed. Otherwise, it will not be clear whether consumption of drinking water is a even appropriate. For example, the future land use that is defined may not even permit access to the contaminated water (e.g., denial of use by law and stewardship; or a lack of accessibility), and in that situation there would be no exposure and no potential health consequences. Taking into consideration that consumption of the groundwater is feasible, the groundwater is deemed unsafe if it contains radionuclide contamination that exceeds the criteria that the United States Environmental Protection Agency (EPA) considers in establishing regulatory standards for drinking water contaminants, including radionuclides generally (i.e., a target range for lifetime excess-cancer risk that is not to exceed 10{sup -4} [1/10,000] and ideally is less than 10{sup -6} [1/1,000,000]) (see EPA, 2000a). Thus, the maximum contaminant levels (MCLs) for substances in drinking water are considered to be health-protective and generally are derived on the basis

  4. Technical preparation of a 300 kWel biomass gasification plant. Report for the project: Simplification, system and operation optimization of staged gasification unit for CHP production (the Castor unit in Graested); Teknisk forberedelse af 300 kWel bioforgasningsanlaeg. En Delrapport til projektet: Forenkling, system- og driftsoptimering af trinopdelt forgasningsanlaeg til kraftvarmeproduktion (Castor anlaegget i Graested)

    Energy Technology Data Exchange (ETDEWEB)

    Houmann Jakobsen, H.

    2009-09-15

    In 2003/04 BioSynergi Proces ApS built a complete approx. 450 kWth Open Core staged gasification unit as a development / demonstration plant. The plant uses wet wood chips as fuel for generating electricity and heat. The facility, known as the Castor plant, is connected to the heat supply network in Graested District Heating. The daily operation is handled by BioSynergi Process. The cogeneration system, that the Castor plant represents, is the basis for this completed project. For technical preparation of the planned future up scaling of the cogeneration system, a test of the function of the gas generator core (reactor core) was performed in this sub-project. It is the central component of the total cogeneration system, and it is also the one who has the greatest influence on the overall gasification process. The experiments have demonstrated that the stage gasification principle, which is in operation at the Castor plant, is also possible to have in operation with the desired process steps in the tested reactor core with four times more capacity. Finalization of the total gas generator in the range of 300 kWel is now being developed in a new project. The simplified experiments, that were possible to perform with the outdoor setup of the reactor core, were, however, not suited to qualitative assessments of the gasification process. (ln)

  5. Geology of the Terra Cimmeria-Utopia Planitia Highland Lowland Transitional Zone: Final Technical Approach and Scientific Results

    Science.gov (United States)

    Skinner, J. A., Jr.; Tanaka, K. L.

    2010-01-01

    The southern Utopia highland-lowland transitional zone extends from northern Terra Cimmeria to southern Utopia Planitia and contains broad, bench-like platforms with depressions, pitted cones, tholi, and lobate flows. The locally occurring geologic units and landforms contrast other transitional regions and record a spatially partitioned geologic history. We systematically delineated and described the geologic units and landforms of the southern Utopia-Cimmeria highland-lowland transitional zone for the production of a 1:1,000,000-scale geologic map (MTMs 10237, 15237, 20237, 10242, 15242, 20242, 10247, 15247, and 20247). Herein, we present technical and scientific results of this mapping project.

  6. 14 CFR 23.1459 - Flight data recorders.

    Science.gov (United States)

    2010-01-01

    ... the recorder does not disable both the cockpit voice recorder and the flight data recorder; and (7) It is in a separate container from the cockpit voice recorder when both are required. If used to comply... unit is installed as a cockpit voice recorder to comply with § 23.1457(e)(2), a combination unit...

  7. How to be an Effective Technical Writer?

    Directory of Open Access Journals (Sweden)

    M Solaiman Ali

    2012-07-01

    Full Text Available Abstract--This paper has focused on technical writing as a skill for engineers. It has sought to define technical writing and throw light on the content and technique of writing the various components of successful technical reports (for example, articles, papers, or research reports, such as theses and dissertations. Then, it has highlighted other special features and principles of effective technical writing. The material in this paper is divided into seven major parts. Part 1 (Technical writing for engineers stresses that a successful engineering career requires strong writing skills. Part 2 (How to write the major sections or elements of a report describes the techniques of writing the abstract, introduction, literature review, procedure/methods & materials, results, discussion, conclusion, and recommendations. Part 3 (Special features of technical writing brings into focus some of the special features of technical writing such as tables & graphs in the text, graphics in instructions, team writing, ethics (plagiarism, document sources, three citation styles and IEEE reference style. Part 4 (Technical usage deals with writing abbreviations, initialisms and acronyms, numbers, units of measurement, and equations.Part 5 (Technical style highlights the imperative writing style and other features of technical writing such as the use of active and passive voices, plain vs. complex syntax, avoiding redundant or superfluous expressions, and vague generalities, using words or expressions with visual impact, the past tense to describe experimental work, the present tense to describe hypotheses, principles, theories and truths, and breaking up the text of the report into short sections. Part 6 (Document specifications emphasizes the technical writer’s need to conform to such document specifications as word count, format, font, number of words per line of text imposed. Part 7 (Reader-friendly technical writing suggests choosing the varied writing modes

  8. The science of sound recording

    CERN Document Server

    Kadis, Jay

    2012-01-01

    The Science of Sound Recording will provide you with more than just an introduction to sound and recording, it will allow you to dive right into some of the technical areas that often appear overwhelming to anyone without an electrical engineering or physics background.  The Science of Sound Recording helps you build a basic foundation of scientific principles, explaining how recording really works. Packed with valuable must know information, illustrations and examples of 'worked through' equations this book introduces the theory behind sound recording practices in a logical and prac

  9. Onshore industrial wind turbine locations for the United States up to March 2014

    Science.gov (United States)

    Diffendorfer, James E.; Kramer, Louisa; Ancona, Zachary H.; Garrity, Christopher P.

    2015-01-01

    Wind energy is a rapidly growing form of renewable energy in the United States. While summary information on the total amounts of installed capacity are available by state, a free, centralized, national, turbine-level, geospatial dataset useful for scientific research, land and resource management, and other uses did not exist. Available in multiple formats and in a web application, these public domain data provide industrial-scale onshore wind turbine locations in the United States up to March 2014, corresponding facility information, and turbine technical specifications. Wind turbine records have been collected and compiled from various public sources, digitized or position verified from aerial imagery, and quality assured and quality controlled. Technical specifications for turbines were assigned based on the wind turbine make and model as described in public literature. In some cases, turbines were not seen in imagery or turbine information did not exist or was difficult to obtain. Uncertainty associated with these is recorded in a confidence rating.

  10. 10 CFR 455.62 - Contents of a technical assistance program.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Contents of a technical assistance program. 455.62 Section... BUILDINGS OWNED BY UNITS OF LOCAL GOVERNMENT AND PUBLIC CARE INSTITUTIONS Technical Assistance Programs for... technical assistance program. (a) The purpose of a technical assistance program is to provide a report based...

  11. DOE technical standards list: Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    This Department of Energy (DOE) technical standards list (TSL) has been prepared by the Office of Nuclear Safety Policy and Standards (EH-31) on the basis of currently available technical information. Periodic updates of this TSL will be issued as additional information is received on standardization documents being issued, adopted, or canceled by DOE. This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listings of current DOE technical standards, non-Government standards that have been adopted by DOE, other standards-related documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  12. 2013 Technical Roundtable

    Science.gov (United States)

    On December 9, 2013, EPA reconvened the study’s Technical Roundtable. Subject-matter experts discussed the outcomes of the 2013 Technical Workshops, stakeholder engagement, and plans for draft assessment report.

  13. Technical Assistance Plan (TAP)

    Science.gov (United States)

    A Technical Assistance Plan (TAP) enables community groups to retain the services of an independent technical advisor and to provide resources for a community group to help inform other community members about site decisions.

  14. Technical training - places available

    CERN Multimedia

    2013-01-01

    If you would like more information on a course, or have any other inquiry/suggestions, please contact Technical.Training@cern.ch. Eva Stern and Elise Romero, Technical Training Administration (Tel: 74924)

  15. Technical training: places available

    CERN Multimedia

    2014-01-01

    If you would like more information on a course, or have any other inquiry/suggestions, please contact Technical.Training@cern.ch. Eva Stern and Marie Lahchimi, Technical Training Administration (Tel: 74924)

  16. Technical training: places available

    CERN Multimedia

    2013-01-01

    If you would like more information on a course, or for any other inquiry/suggestions, please contact Technical.Training@cern.ch. Eva Stern and Elise Romero, Technical Training Administration (Tel: 74924)

  17. Technical training: places available

    CERN Multimedia

    2013-01-01

    If you would like more information on a course, or for any other inquiry/suggestions, please contact Technical.Training@cern.ch. Eva Stern and Elise Romero, Technical Training Administration (Tél : 74924)  

  18. Technical training: places available

    CERN Multimedia

    2014-01-01

    If you would like more information on a course, or have any other inquiry/suggestions, please contact Technical.Training@cern.ch. Eva Stern and Elise Romero, Technical Training Administration (Tel: 74924)

  19. Record dynamics

    DEFF Research Database (Denmark)

    Robe, Dominic M.; Boettcher, Stefan; Sibani, Paolo

    2016-01-01

    -facto irreversible and become increasingly harder to achieve. Thus, a progression of record-sized dynamical barriers are traversed in the approach to equilibration. Accordingly, the statistics of the events is closely described by a log-Poisson process. Originally developed for relaxation in spin glasses...

  20. Study of technical and economical feasibility for implementation of a movable unit for treatment of industrial effluents with electron beam; Estudo de viabilidade tecnica e economica para implementacao de uma unidade movel para tratamento de efluentes industriais com feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Rela, Carolina Sciamarelli

    2006-07-01

    The treatment of industrial effluents is a practice that is disseminating in accelerated rhythm, of contributing to reinforce the public image, through the combat of the pollution, it brings economical advantages allowing the companies the reuse of the treated water in their own processes. The liquid effluent treatment technique studied in the present work is the one that uses the chemical oxidation/reduction standing out the use of the electron beam (e.b.) radiation. This technique uses an advanced oxidation process, generating radicals highly reagents that provoke the oxidation, reduction, dissociation and degradation in composed organic and exercising lethal effect in general in the microorganisms and parasites. In this work a conceptual and basic project of a movable unit of effluents treatment using electron beam radiation process was developed, in order that the unit moves until the treatment point, where the effluent is produced, facilitating the logistics. A technical and economical feasibility study was also elaborated allowing data on the capacity and cost of effluents processing to consolidate the values of the necessary investments to be presented to foundations organs for the construction of a movable unit. The results of the studies demonstrated that it is technically viable attending the pertinent legislation of Brazil, in the aspects of Radiation Protection and transport limit capacity. The unitary cost of the e.b. radiation processing in the movable unit was shown more expensive than in the fixed unit, the reason is the decrease of the efficiency of the interaction of the incident electrons in the effluent, due to the reduction of electron energy operation time of the unit. (author)

  1. Teaching Technical Writing - Towards Technical Writing

    DEFF Research Database (Denmark)

    Kastberg, Peter

    2000-01-01

    In this paper I will present key aspects of the curriculum for the university degree in technical translation that I have designed for and subsequently implemented at the German Department of the Aarhus School of Business, Denmark. My starting point will be a critical discussion of the norm...... that used to govern what the quality of an LSP text should be as opposed to the standpoint, which I advocate. By way of summing up, I will show how a university curriculum is designed so that - upon graduation - the technical translator could also be methodological quite well suited to take on the challenge...... of technical writing....

  2. 76 FR 64083 - Reliability Technical Conference; Notice of Technical Conference

    Science.gov (United States)

    2011-10-17

    ... Energy Regulatory Commission Reliability Technical Conference; Notice of Technical Conference Take notice that the Federal Energy Regulatory Commission will hold a Technical Conference on Tuesday, November 29... addressing risks to reliability that were identified in earlier Commission technical conferences....

  3. NASA/DoD Aerospace Knowledge Diffusion Research Project: Chronology of Selected Literature, Reports, Policy Instruments, and Significant Events Affecting Federal Scientific and Technical Information (STI) in the United States, 1945-1990. Report Number 11.

    Science.gov (United States)

    Pinelli, Thomas E.; And Others

    The chronology is a comprehensive bibliography covering a variety of selected literature, reports, policy instruments, and significant events affecting federal scientific and technical information (STI) from 1945 to 1990. It includes some publications and events of historic interest that relate to the evolution of aerospace and aerospace knowledge…

  4. ATLAS Recordings

    CERN Multimedia

    Steven Goldfarb; Mitch McLachlan; Homer A. Neal

    Web Archives of ATLAS Plenary Sessions, Workshops, Meetings, and Tutorials from 2005 until this past month are available via the University of Michigan portal here. Most recent additions include the Trigger-Aware Analysis Tutorial by Monika Wielers on March 23 and the ROOT Workshop held at CERN on March 26-27.Viewing requires a standard web browser with RealPlayer plug-in (included in most browsers automatically) and works on any major platform. Lectures can be viewed directly over the web or downloaded locally.In addition, you will find access to a variety of general tutorials and events via the portal.Feedback WelcomeOur group is making arrangements now to record plenary sessions, tutorials, and other important ATLAS events for 2007. Your suggestions for potential recording, as well as your feedback on existing archives is always welcome. Please contact us at wlap@umich.edu. Thank you.Enjoy the Lectures!

  5. Fluor Hanford, Inc. Groundwater and Technical Integration Support (Master Project) Quality Assurance Management Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fix, N. J.

    2008-02-20

    The scope of the Fluor Hanford, Inc. Groundwater and Technical Integration Support (Master Project) is to provide technical and integration support to Fluor Hanford, Inc., including operable unit investigations at 300-FF-5 and other groundwater operable units, strategic integration, technical integration and assessments, remediation decision support, and science and technology. This Quality Assurance Management Plan provides the quality assurance requirements and processes that will be followed by the Fluor Hanford, Inc. Groundwater and Technical Integration Support (Master Project).

  6. Integrating technical and non-technical skills coaching in an acute trauma surgery team training: Is it too much?

    Science.gov (United States)

    Alken, Alexander; Luursema, Jan-Maarten; Weenk, Mariska; Yauw, Simon; Fluit, Cornelia; van Goor, Harry

    2017-08-25

    Research on effective integration of technical and non-technical skills in surgery team training is sparse. In a previous study we found that surgical teachers predominantly coached on technical and hardly on non-technical skills during the Definitive Surgical and Anesthetic Trauma Care (DSATC) integrated acute trauma surgery team training. This study aims to investigate whether the priming of teachers could increase the amount of non-technical skills coaching during such a training. Coaching activities of 12 surgical teachers were recorded on audio and video. Six teachers were primed on non-technical skills coaching prior to the training. Six others received no priming and served as controls. Blind observers reviewed the recordings of 2 training scenario's and scored whether the observed behaviors were directed on technical or non-technical skills. We compared the frequency of the non-technical skills coaching between the primed and the non-primed teachers and analyzed for differences according to the trainees' level of experience. Surgical teachers coached trainees during the highly realistic DSATC integrated acute trauma surgery team training. Trainees performed damage control surgery in operating teams on anesthetized porcine models during 6 training scenario's. Twelve experienced surgical teachers participated in this study. Coaching on non-technical skills was limited to about 5%. The primed teachers did not coach more often on non-technical skills than the non-primed teachers. We found no differences in the frequency of non-technical skills coaching based on the trainees' level of experience. Priming experienced surgical teachers does not increase the coaching on non-technical skills. The current DSATC acute trauma surgery team training seems too complex for integrating training on technical and non-technical skills. Patient care, Practice based learning and improvement. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Assessing the dose values received by patients during conventional radiography X-ray examinations and the technical condition of the equipment used for this purpose

    Directory of Open Access Journals (Sweden)

    Marcin Bekas

    2014-12-01

    Full Text Available Background: X-ray examination is associated with patient exposure to ionizing radiation. Dose values depend on the type of medical procedure used, the X-ray unit technical condition and exposure conditions selected. The aim of this study was to determine the dose value received by patients during certain conventional radiography X-ray examinations and to assess the technical condition of medical equipment used for this purpose. Material and Methods: The study covered the total number of 118 conventional diagnostic X-ray units located in the Masovian Voivodeship. The methodology used to assess the conventional diagnostic X-ray unit technical condition and the measurement of the radiation dose rate received by patients are based on test procedures developed by the Department of Radiation Protection and Radiobiology of the National Institute of Public Health – National Institute of Hygiene (Warszawa, Poland accredited for compliance with PN-EN 17025 standard by the Polish Centre for Accreditation. Results: It was found that 84.7% of X-ray units fully meet the criteria set out in the Polish legislation regarding the safe use of ionizing radiation in medicine, while 15.3% of the units do not meet some of them. The broadest dose value range was recorded for adult patients. Particularly, during lateral (LAT lumbar spine radiography the recorded entrance surface dose (ESD values ranged from 283.5 to 7827 μGy (mean: 2183.3 μGy. Conclusions: It is absolutely necessary to constantly monitor the technical condition of all X-ray units, because it affects population exposure to ionizing radiation. Furthermore, it is essential to raise radiographers’ awareness of the effects that ionizing radiation exposure can have on the human body. Med Pr 2014;65(6:715–721

  8. Record club

    CERN Multimedia

    Record club

    2010-01-01

      Bonjour a tous, Voici les 24 nouveaux DVD de Juillet disponibles depuis quelques jours, sans oublier les 5 CD Pop musique. Découvrez la saga du terroriste Carlos, la vie de Gainsbourg et les aventures de Lucky Luke; angoissez avec Paranormal Activity et évadez vous sur Pandora dans la peau d’Avatar. Toutes les nouveautés sont à découvrir directement au club. Pour en connaître la liste complète ainsi que le reste de la collection du Record Club, nous vous invitons sur notre site web: http://cern.ch/crc. Toutes les dernières nouveautés sont dans la rubrique « Discs of the Month ». Rappel : le club est ouvert les Lundis, Mercredis, Vendredis de 12h30 à 13h00 au restaurant n°2, bâtiment 504. A bientôt chers Record Clubbers.  

  9. Record Club

    CERN Multimedia

    Record Club

    2011-01-01

    http://cern.ch/Record.Club November  Selections Just in time for the holiday season, we have added a number of new CDs and DVDs into the Club. You will find the full lists at http://cern.ch/record.club; select the "Discs of the Month" button on the left side on the left panel of the web page and then Nov 2011. New films include the all 5 episodes of Fast and Furious, many of the most famous films starring Jean-Paul Belmondo and those of Louis de Funes and some more recent films such as The Lincoln Lawyer and, according to some critics, Woody Allen’s best film for years – Midnight in Paris. For the younger generation there is Cars 2 and Kung Fu Panda 2. New CDs include the latest releases by Adele, Coldplay and the Red Hot Chili Peppers. We have also added the new Duets II CD featuring Tony Bennett singing with some of today’s pop stars including Lady Gaga, Amy Winehouse and Willy Nelson. The Club is now open every Monday, Wednesday and Friday ...

  10. ATLAS Recordings

    CERN Multimedia

    Jeremy Herr; Homer A. Neal; Mitch McLachlan

    The University of Michigan Web Archives for the 2006 ATLAS Week Plenary Sessions, as well as the first of 2007, are now online. In addition, there are a wide variety of Software and Physics Tutorial sessions, recorded over the past couple years, to chose from. All ATLAS-specific archives are accessible here.Viewing requires a standard web browser with RealPlayer plug-in (included in most browsers automatically) and works on any major platform. Lectures can be viewed directly over the web or downloaded locally.In addition, you will find access to a variety of general tutorials and events via the portal. Shaping Collaboration 2006The Michigan group is happy to announce a complete set of recordings from the Shaping Collaboration conference held last December at the CICG in Geneva.The event hosted a mix of Collaborative Tool experts and LHC Users, and featured presentations by the CERN Deputy Director General, Prof. Jos Engelen, the President of Internet2, and chief developers from VRVS/EVO, WLAP, and other tools...

  11. Record Club

    CERN Multimedia

    Record Club

    2011-01-01

    http://cern.ch/Record.Club Nouveautés été 2011 Le club de location de CDs et de DVDs vient d’ajouter un grand nombre de disques pour l’été 2011. Parmi eux, Le Discours d’un Roi, oscar 2011 du meilleur film et Harry Potter les reliques de la mort (1re partie). Ce n’est pas moins de 48 DVDs et 10 CDs nouveaux qui vous sont proposés à la location. Il y en a pour tous les genres. Alors n’hésitez pas à consulter notre site http://cern.ch/record.club, voir Disc Catalogue, Discs of the month pour avoir la liste complète. Le club est ouvert tous les Lundi, Mercredi, Vendredi de 12h30 à 13h dans le bâtiment du restaurent N°2 (Cf. URL: http://www.cern.ch/map/building?bno=504) A très bientôt.  

  12. Record Club

    CERN Multimedia

    Record Club

    2011-01-01

    http://cern.ch/Record.Club June Selections We have put a significant number of new CDs and DVDs into the Club You will find the full lists at http://cern.ch/record.club and select the «Discs of the Month» button on the left side on the left panel of the web page and then June 2011. New films include the latest Action, Suspense and Science Fiction film hits, general drama movies including the Oscar-winning The King’s Speech, comedies including both chapter of Bridget Jones’s Diary, seven films for children and a musical. Other highlights include the latest Harry Potter release and some movies from the past you may have missed including the first in the Terminator series. New CDs include the latest releases by Michel Sardou, Mylene Farmer, Jennifer Lopez, Zucchero and Britney Spears. There is also a hits collection from NRJ. Don’t forget that the Club is now open every Monday, Wednesday and Friday lunchtimes from 12h30 to 13h00 in Restaurant 2, Building 504. (C...

  13. 36 CFR 228.50 - Production records.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 2 2010-07-01 2010-07-01 false Production records. 228.50... Disposal of Mineral Materials General Provisions § 228.50 Production records. At least annually, the..., to the authorized officer. The units of measurement must correspond to the units used in...

  14. Automatic counting and recording unit used for dating by the carbon 14 method; Ensemble de comptage et d'impression automatique utilise pour la datation par la methode du carbone 14

    Energy Technology Data Exchange (ETDEWEB)

    Albertinoli, P.; Galliot, J.; Thommeret, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Centre Scientifique de Monaco, Monte Carlo

    1969-07-01

    A description is given of the unit used by the 'Centre Scientifique de Monaco' for low-level beta counting and fitted for radioactive dating by the Carbon 14 method. Built entirely by the laboratory in 1964, on the basis of electronic techniques then recent, it has worked without failure since that time. The proportional counter, its high-voltage negative supply, and the counting chains with visual and printing records are detailed by means of 38 figures which reproduce the counter and the electronic circuits. These are contained in two standard 5 U.I structures. The low-voltage power supply of the whole unit is carried out by plus 12 volts and minus 12 volts storage batteries, buffered on a charger connected on the 110 V alternative line. The proportional counter described is filled with CO{sub 2} under one atmosphere pressure and permits the dating of carbonaceous samples with a maximum of 30.000 + 1.000 years (background 3.96 c.p.m. ) within a moderate time (72 hours). (authors) [French] L'ensemble de comptage pour radioactivite beta a bas niveau, destine a la datation par la methode du carbone 14, utilise au Centre Scientifique de Monaco, est decrit. Entierement construit au laboratoire en 1964, sur la base de techniques electroniques alors recentes, il fonctionne depuis cette date sans defaillance. Le compteur proportionnel, son alimentation haute tension negative et les chaines de comptage transistorisees a affichage et impression sont detailles par 38 schemas reproduisant le compteur et les divers circuits electroniques. Ceux-ci sont contenus dans deux chassis standard 5 UI. L'alimentation basse tension de l'ensemble est obtenue par batteries plus 12 et moins 12 volts montees en tampon sur chargeur alimente par le reseau. Le compteur proportionnel decrit, rempli de CO2 sous une atmosphere, permet de dater les echantillons carbones avec un maximum de 30.000 + 1.000 ans (bruit de fond: 3,96 c.p.m. ) en un temps raisonnable (72 heures

  15. UK National Data Centre archive of seismic recordings of (presumed) underground nuclear tests 1964-1996

    Science.gov (United States)

    Young, John; Peacock, Sheila

    2016-04-01

    The year 1996 has particular significance for forensic seismologists. This was the year when the Comprehensive Test Ban Treaty (CTBT) was signed in September at the United Nations, setting an international norm against nuclear testing. Blacknest, as a long time seismic centre for research into detecting and identifying underground explosions using seismology, provided significant technical advice during the CTBT negotiations. Since 1962 seismic recordings of both presumed nuclear explosions and earthquakes from the four seismometer arrays Eskdalemuir, Scotland (EKA), Yellowknife, Canada (YKA), Gauribidanur, India (GBA), and Warramunga, Australia (WRA) have been copied, digitised, and saved. There was a possibility this archive would be lost. It was decided to process the records and catalogue them for distribution to other groups and institutions. This work continues at Blacknest but the archive is no longer under threat. In addition much of the archive of analogue tape recordings has been re-digitised with modern equipment, allowing sampling rates of 100 rather than 20 Hz.

  16. Records and record-keeping for the hospital compounding pharmacist.

    Science.gov (United States)

    McElhiney, Linda F

    2007-01-01

    The United States Pharmacopeial Convention, Inc., is recognized by federal law and by most state boards of pharmacy as the official group for setting the standards for pharmaceuticals and pharmacy practice, including compounding. The standards of United States Pharmacopeia Chapter 795 require that a pharmacy maintain records on a compounded preparation, including the formulation record, and a Material Safety Data Sheets file. The American Society of Health-Systems Pharmacists' guidelines require that hospital pharmacy departments maintain at least four sets of records in the compounding area: (1) compounding formulas and procedures, (2) compounding logs of all compounded preparations, including batch records and sample batch labels, (3) equipment maintenance records, and (4) a record of ingredients purchased, including cerificates of analysis and Material Saftey Data Sheets. Hospital compounding records may be inspected by any of several outside organizations, including state boards of pharmacy, third-party payers, the Joint Commission on Accreditaion of Healthcare Organizations, the Drug Enforcement Agency, and attorneys. With the existing standards and guidelines in place and the importance of documentation unquestionable, a record of pharmacy activites should be maintained in a compounding pharmacy so that preparations can be replicated consistently, the history of each ingredient traced, equipment maintenance and calibration verified, and compounding procedures evaluated easily.

  17. RECORD CLUB

    CERN Multimedia

    Record Club

    2010-01-01

    DVD James Bond – Series Complete To all Record Club Members, to start the new year, we have taken advantage of a special offer to add copies of all the James Bond movies to date, from the very first - Dr. No - to the latest - Quantum of Solace. No matter which of the successive 007s you prefer (Sean Connery, George Lazenby, Roger Moore, Timothy Dalton, Pierce Brosnan or Daniel Craig), they are all there. Or perhaps you have a favourite Bond Girl, or even perhaps a favourite villain. Take your pick. You can find the full selection listed on the club web site http://cern.ch/crc; use the panel on the left of the page “Discs of the Month” and select Jan 2010. We remind you that we are open on Mondays, Wednesdays and Fridays from 12:30 to 13:00 in Restaurant 2 (Bldg 504).

  18. Record breakers

    CERN Document Server

    Antonella Del Rosso

    2012-01-01

    In the sixties, CERN’s Fellows were but a handful of about 50 young experimentalists present on site to complete their training. Today, their number has increased to a record-breaking 500. They come from many different fields and are spread across CERN’s different activity areas.   “Diversifying the Fellowship programme has been the key theme in recent years,” comments James Purvis, Head of the Recruitment, Programmes and Monitoring group in the HR Department. “In particular, the 2005 five-yearly review introduced the notion of ‘senior’ and ‘junior’ Fellowships, broadening the target audience to include those with Bachelor-level qualifications.” Diversification made CERN’s Fellowship programme attractive to a wider audience but the number of Fellows on site could not have increased so much without the support of EU-funded projects, which were instrumental in the growth of the programme. ...

  19. Career and Technical Education at a Crossroads: A Delphi Study

    Science.gov (United States)

    Cutright, Michael W.

    2011-01-01

    Career and technical education in the United States has reached a critical juncture. A three round Delphi method was used to determine a consensus on the future events of career and technical education to better inform educational decision makers. Forty-one individual experts in the field were invited to serve as panelists for the Delphi study and…

  20. Análise retrospectiva dos registros de enfermagem em uma unidade especializada Análisis retrospectivo de los registros de enfermaría en una unidad especializada Retrospective analysis of nursing records at a specialized unit

    Directory of Open Access Journals (Sweden)

    Kattia Ochoa-Vigo

    2003-03-01

    íodos inicial e de implementación, situación que expresa necesidad de rever el modo de desarrollar el Proceso de Enfermería como responsabilidad de todos los miembros del equipo de enfermería.This is a retrospective longitudinal study conducted in a Specialized Unit in the interior of Brazil. It aimed at verifying differences in nursing records with regard to how to document the care provided to patients in three periods related to the implementation of the Nursing process. Data were collected from 20% of the records of patients aged over 15 years who were randomly selected according to proportional distribution. Such data were fully transcribed in an instrument constructed for this purpose and classified according to the proposals of the referential. The Binomial Test was used for analysis with a significance level of 0.05%. The results showed a tendency to improvement of the records as to writing intellection and complete description of the signs/symptoms in the second period. It was concluded that there was a difference between the initial and the pre-implementation periods, which expresses the need to review the way the Nursing Process must be developed as a responsibility of the whole nursing team.

  1. Impact of the WHO Technical Support Towards Malaria Elimination ...

    African Journals Online (AJOL)

    2University of Zambia, School of Medicine, Lusaka, Zambia. Key words: Malaria, strategies, technical support, WHO. ABSTRACT. Background: Zambia's National Malaria Strategic Plan .... the Disaster Management and Mitigation Unit (DMMU).

  2. NASA/DOD Aerospace Knowledge Diffusion Research Project. Report 11: Chronology of selected literature, reports, policy instruments, and significant events affecting Federal Scientific and Technical Information (STI) in the United States

    Science.gov (United States)

    Pinelli, Thomas E.; Henderson, Madeline; Bishop, Ann P.; Doty, Philip

    1992-01-01

    The chronology is a comprehensive bibliography. It contains 512 entries covering a variety of selected literature, reports, policy instruments, and significant events affecting Federal Scientific and Technical Information (STI) from 1945 to 1990. It includes some publications and events of historic interest which relate to the evaluation of aerospace and aerospace knowledge diffusion. Each entry has been given an item number and items are arranged by columns. To provide an overview of Federal STI developments, the entries are generally arranged by date of publication and event.

  3. DOE technical standards list: Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This technical standards list (TSL) was prepared for use by personnel involved in the selection and use of US DOE technical standards and other government and non-government standards. This TSL provides listings of current DOE technical standards, non-government standards that have been adopted by DOE, other government documents in which DOE has a recorded interest, and cancelled DOE technical standards. Standards are indexed by type in the appendices to this document. Definitions of and general guidance for the use of standards are also provided.

  4. Record Club

    CERN Multimedia

    Record Club

    2012-01-01

      March  Selections By the time this appears, we will have added a number of new CDs and DVDs into the Club. You will find the full lists at http://cern.ch/record.club; select the "Discs of the Month" button on the left panel of the web page and then Mar 2012. New films include recent releases such as Johnny English 2, Bad Teacher, Cowboys vs Aliens, and Super 8. We are also starting to acquire some of the classic films we missed when we initiated the DVD section of the club, such as appeared in a recent Best 100 Films published by a leading UK magazine; this month we have added Spielberg’s Jaws and Scorsese’s Goodfellas. If you have your own ideas on what we are missing, let us know. For children we have no less than 8 Tin-Tin DVDs. And if you like fast moving pop music, try the Beyonce concert DVD. New CDs include the latest releases from Paul McCartney, Rihanna and Amy Winehouse. There is a best of Mylene Farmer, a compilation from the NRJ 201...

  5. Transformation of technical infrastructure

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev

    1998-01-01

    article about the need of new planning forums in order to initiate transformations with in management of large technical systems for energy, waste and water supply.......article about the need of new planning forums in order to initiate transformations with in management of large technical systems for energy, waste and water supply....

  6. Technical Communication in Japan

    Institute of Scientific and Technical Information of China (English)

    Hiraku Amemiya

    2010-01-01

    @@ 1.Characteristics of Japanese Technical Communication(TC) The visual orientation of information characterizes Japanese technical communication.Manuals that have won Japan Manual Awards in the past have employed various designs with graphical presentations that evoke the style of popular magazines.

  7. Technical Manual. The ACT®

    Science.gov (United States)

    ACT, Inc., 2014

    2014-01-01

    This manual contains technical information about the ACT® college readiness assessment. The principal purpose of this manual is to document the technical characteristics of the ACT in light of its intended purposes. ACT regularly conducts research as part of the ongoing formative evaluation of its programs. The research is intended to ensure that…

  8. Summer Technical Students 2004

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    About 100 technical and doctoral students arrive each year, undergraduates and post-graduates who are preparing diploma or doctoral theses in applied science and technology. They spend up to two years at the Laboratory, as technical students as part of their formal training for a recognised degree or its equivalent.

  9. Technical Program, 1974,

    Science.gov (United States)

    proposed AGARD Technical Program and Budget for 1974. The report reflects the program that was unanimously approved by the AGARD National Delegates Board...required to support the proposed 1974 AGARD technical program is presented in Section 3. The separate publications summary shown in Section 4 identifies by

  10. usage of electronic health records

    Directory of Open Access Journals (Sweden)

    Songul Cinaroglu

    2015-06-01

    Full Text Available Health care is an organizational field that information and technology improves quickly. With ensuring health professionals adaptation to this new information and technology environment, it is possible to achieve quality and productivity improvement goal in health care. It is known that different clinical expertises brings differences in presentation of health services. It this study it was aimed to compare nurses assessments about electronic health records usage. At the end of the study it was found that nurses assessment about electronic health records usage according to different clinical expertises has a meaningful difference (t=2,40, p<0,05. Results of this study shows that surgical nurses who are forefront with and ldquo;technical abilities and rdquo; have more positive assessments about usage of electronic medical records when they compared with medical nurses who are forefront with and ldquo;patient centered and rdquo; abilities. [TAF Prev Med Bull 2015; 14(3.000: 257-264

  11. Human research ethics committees in technical universities.

    Science.gov (United States)

    Koepsell, David; Brinkman, Willem-Paul; Pont, Sylvia

    2014-07-01

    Human research ethics has developed in both theory and practice mostly from experiences in medical research. Human participants, however, are used in a much broader range of research than ethics committees oversee, including both basic and applied research at technical universities. Although mandated in the United States, the United Kingdom, Canada, and Australia, non-medical research involving humans need not receive ethics review in much of Europe, Asia, Latin America, and Africa. Our survey of the top 50 technical universities in the world shows that, where not specifically mandated by law, most technical universities do not employ ethics committees to review human studies. As the domains of basic and applied sciences expand, ethics committees are increasingly needed to guide and oversee all such research regardless of legal requirements. We offer as examples, from our experience as an ethics committee in a major European technical university, ways in which such a committee provides needed services and can help ensure more ethical studies involving humans outside the standard medical context. We provide some arguments for creating such committees, and in our supplemental article, we provide specific examples of cases and concerns that may confront technical, engineering, and design research, as well as outline the general framework we have used in creating our committee.

  12. Technical Writing in the Netherlands.

    Science.gov (United States)

    de Vet, Dominique M. W.

    1996-01-01

    Discusses the technical writing profession in the Netherlands. Bases the discussion on two studies--one directed at technical freelancers and another directed at technical writers working within organizations. Gives a profile of technical writers in the Netherlands; an impression of the problems technical writers in organizations deal with;…

  13. Technical evaluation report TMI action -- NUREG-0737 (II.D.1). Relief and safety valve testing, Watts Bar Nuclear Plant, Units 1 and 2 (Dockets 50-390 and 50-391)

    Energy Technology Data Exchange (ETDEWEB)

    Fineman, C.P.

    1995-02-01

    In the past, safety and relief valves installed in the primary coolant system of light water reactors have performed improperly. As a result, the authors of NUREG-0578 (TMI-2 Lessons Learned Task Force Status Report and Short-Term Recommendations) and, subsequently, NUREG-0737 (Clarification of TMI Action Plan Requirements) recommended development and completion of programs to do two things. First, they should reevaluate the functional performance capabilities of pressurized water reactor safety, relief, and block valves. Second, they should verify the integrity of the pressurizer safety and relief valve piping systems for normal, transient, and accident conditions. This report documents the review of those programs by Lockheed Idaho Technologies Company. Specifically, this report documents the review of the Watts Bar Nuclear Plant, Units 1 and 2, Applicant response to the requirements of NUREG-0578 and NUREG-0737. This review found the Applicant provided an acceptable response reconfirming they met General Design Criteria 14, 15, and 30 of Appendix A to 10 CFR 50 for the subject equipment. It should also be noted Lockheed Idaho performed this review for both Units 1 and 2. However, the applicability of this review to Unit 2 depends on verifying that the Unit 2 as-built system conforms to the Unit 1 design reviewed in this report.

  14. Electronic Ambient-Temperature Recorder

    Science.gov (United States)

    Russell, Larry; Barrows, William

    1995-01-01

    Electronic temperature-recording unit stores data in internal memory for later readout. Records temperatures from minus 40 degrees to plus 60 degrees C at intervals ranging from 1.875 to 15 minutes. With all four data channels operating at 1.875-minute intervals, recorder stores at least 10 days' data. For only one channel at 15-minute intervals, capacity extends to up to 342 days' data. Developed for recording temperatures of instruments and life-science experiments on satellites, space shuttle, and high-altitude aircraft. Adaptable to such terrestrial uses as recording temperatures of perishable goods during transportation and of other systems or processes over long times. Can be placed directly in environment to monitor.

  15. Inlet Geomorphology Evolution Work Unit

    Science.gov (United States)

    2015-10-30

    the expected behavior and benefits of nearshore placement. Nearshore placement studies have been documented in two journal papers, one technical...Coastal Inlets Research Program Inlet Geomorphology Evolution Work Unit The Inlet Geomorphology Evolution work unit of the CIRP develops methods...sensing measurements, and USACE projects to create valuable guidance that address geomorphic questions. The present focus of the work unit is a common

  16. 14 CFR 25.1459 - Flight data recorders.

    Science.gov (United States)

    2010-01-01

    ... to the recorder does not disable both the cockpit voice recorder and the flight data recorder; and (8) It is in a separate container from the cockpit voice recorder when both are required. If used to... combination unit is installed as a cockpit voice recorder to comply with § 25.1457(e)(2), a combination...

  17. Electronic Health Record Systems and Intent to Apply for Meaningful Use Incentives among Office-based Physician ...

    Science.gov (United States)

    ... Order from the National Technical Information Service NCHS Electronic Health Record Systems and Intent to Apply for ... In 2011, 57% of office-based physicians used electronic medical record/electronic health record (EMR/EHR) systems, ...

  18. Technical assistance in relationship with the reloading analysis of the Laguna Verde Unit 2 reactor. Executive abstract; Asistencia tecnica en relacion con el analisis de recargas de la CNLV U-2

    Energy Technology Data Exchange (ETDEWEB)

    Alonso V, G.; Castro B, M.; Gallegos E, R.; Hernandez L, H.; Montes T, J.L.; Ortiz S, J. J.; Perusquia C, R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1993-11-15

    The objective of the report was to carry out a comparative analysis of costs of energy generation among the designs GE9B of General Electric, 9X9-IX of SIEMENS and SVEA-96 of ABB ATOM, proposed to be used as recharge fuel in the Unit 2 of the Laguna Verde Nuclear Power station. (Author)

  19. Milestones for National Technical

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    The first session of National Technical Committee of Auto Standardization was established onApri128,1988. The first session of National Technical Committee of Auto Standardization (SAC/TC 114)was established in Beijing on April 28,1988,under the approval of the National Bureau of Standards at that time,with the official from China Association of Automobile Manufacturers as its director.It played a very impoorant role,not only in the unified management of auto standards but also in the technical work of the management of auto products.

  20. TCR as supervisor of technical systems

    CERN Document Server

    Laeger, H

    1998-01-01

    Our Technical Control Room (TCR) provides continuous supervision of CERN's technical infrastructure. It also serves the inhabitants of CERN's premises as a contact point in case of problems. Every year we initiate eleven thousand recorded corrective interventions; about half subsequent to user phone calls, the other half to automatic alarms. TCR tasks are essentially fourfold: collect and distribute information on abnormal operation states; supervise those technical systems for which we have a mandate; initiate corrective interventions; and perform corrective on-site interventions outside normal working hours. A TCR operator normally has an education corresponding to a French BTS and initially little professional experience. He holds short-term contracts, up to a maximum of six years. This paper outlines TCR tasks and presents some statistical data. It also indicates relations between users, equipment groups, contract firms and the TCR as go-between. Finally, it gives an account of our seven years experience ...

  1. Small physician practices in new york needed sustained help to realize gains in quality from use of electronic health records.

    Science.gov (United States)

    Ryan, Andrew M; Bishop, Tara F; Shih, Sarah; Casalino, Lawrence P

    2013-01-01

    The 2009 American Recovery and Reinvestment Act spurred adoption of electronic health records (EHRs) in the United States, through such measures as financial incentives to providers through Medicare and Medicaid and regional extension centers, which provide ongoing technical assistance to practices. Yet the relationship between EHR adoption and quality of care remains poorly understood. We evaluated the early effects on quality of the Primary Care Information Project, which provides subsidized EHRs and technical assistance to primary care practices in underserved neighborhoods in New York City, using the regional extension center model. We found that just general participation in, or exposure to, the project was not enough to improve quality of care. It took sustained exposure on the part of these practices and technical assistance to them before they demonstrated improvement on measures of care most likely to be affected by the use of electronic health records, such as cancer screenings and care for patients with diabetes. Participating in the Primary Care Information Project for nine or more months was associated with significantly improved quality, but only for this limited group of quality measures and only for physicians receiving extensive technical assistance.

  2. The dose received by patients during dental X-ray examination and the technical condition of radiological equipment

    Directory of Open Access Journals (Sweden)

    Marcin Bekas

    2013-12-01

    Full Text Available Background: Implementation of X-ray dental examination is associated with the patient's exposure to ionizing radiation. The size of the exposure depends on the type of medical procedure, the technical condition of the X-ray unit and selected exposure conditions. The aim of this study was to determine the dose received by patients during dental X-ray examination and the assessment of the technical condition of medical equipment. Materials and Methods: The study included a total number of 79 dental X-ray units located in the region of Mazovia. The test methods for the assessment of the technical condition of dental X-ray units and measurement of radiation dose received by patients were based on the procedures elaborated in the Department of Radiation Hygiene and Radiobiology in the National Institute of Public Health - National Institute of Hygiene (Warszawa, Poland accredited for the certification of compliance with PN-EN 17025. Results: The research found that 69.6% fully meets the criteria set out in the Polish legislation regarding the safe use of ionizing radiation in medicine, while 30.4% did not meet some of them. A tenfold difference in the size of the dose received by patients during dental X-ray examinations was discovered. For example, during a radiography of the canine teeth of a child, the recorded entrance surface dose (ESD ranged from 72.8 to 2430 μGy with the average value of 689.1 μGy. Cases where the dose reference level defined in Polish legislation of 5 mGy was exceeded were also found. Conclusions: It is essential to constantly monitor the situation regarding the technical condition of X-ray units which affects the size of the population's exposure to ionizing radiation as well as raising dentists' awareness about the effects of X-rays on the human body. Med Pr 2013;64(6:755–759

  3. United Kingdom Shadow Secretary of State for Universities and Skills David Willetts MP (centre) in front of the CMS detector with (from left to right) A. Barr, Partner and Founder, Matterhorn Investment Management LLP P. Bate, S. Harper, M. Willetts, T. Virdee, J. Ellis, CMS Spokesperson G. Tonelli, CMS Technical Coordinator A. Ball and (front) Partner, Caravel Capital H. Hsueh and P. Wells. Monday 4th January 2010

    CERN Multimedia

    Maximilien Brice; Point 5

    2010-01-01

    United Kingdom Shadow Secretary of State for Universities and Skills David Willetts MP (centre) in front of the CMS detector with (from left to right) A. Barr, Partner and Founder, Matterhorn Investment Management LLP P. Bate, S. Harper, M. Willetts, T. Virdee, J. Ellis, CMS Spokesperson G. Tonelli, CMS Technical Coordinator A. Ball and (front) Partner, Caravel Capital H. Hsueh and P. Wells. Monday 4th January 2010

  4. NCDC Technical Reports

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCDC Technical Reports is a set of retrospective analyses produced by the Research Customer Service Group and the National Climatic Data Center from 1995 to 2008....

  5. Technical report writing today

    CERN Document Server

    Riordan, Daniel G

    2014-01-01

    "Technical Report Writing Today" provides thorough coverage of technical writing basics, techniques, and applications. Through a practical focus with varied examples and exercises, students internalize the skills necessary to produce clear and effective documents and reports. Project worksheets help students organize their thoughts and prepare for assignments, and focus boxes highlight key information and recent developments in technical communication. Extensive individual and collaborative exercises expose students to different kinds of technical writing problems and solutions. Annotated student examples - more than 100 in all - illustrate different writing styles and approaches to problems. Numerous short and long examples throughout the text demonstrate solutions for handling writing assignments in current career situations. The four-color artwork in the chapter on creating visuals keeps pace with contemporary workplace capabilities. The Tenth Edition offers the latest information on using electronic resum...

  6. Superfund Technical Assistance Grants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This asset includes data related to the Superfund Technical Assistance Grant program, including grant number, award amounts, award dates, period of performance,...

  7. OSH technical reference manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    In an evaluation of the Department of Energy (DOE) Occupational Safety and Health programs for government-owned contractor-operated (GOCO) activities, the Department of Labor`s Occupational Safety and Health Administration (OSHA) recommended a technical information exchange program. The intent was to share written safety and health programs, plans, training manuals, and materials within the entire DOE community. The OSH Technical Reference (OTR) helps support the secretary`s response to the OSHA finding by providing a one-stop resource and referral for technical information that relates to safe operations and practice. It also serves as a technical information exchange tool to reference DOE-wide materials pertinent to specific safety topics and, with some modification, as a training aid. The OTR bridges the gap between general safety documents and very specific requirements documents. It is tailored to the DOE community and incorporates DOE field experience.

  8. Technical Report Writing Today

    DEFF Research Database (Denmark)

    Riordan, Daniel G.

    2014-01-01

    Section 1: Technical Communication Basics (8 chapters on tech com, audiences, tech com process, tech com style, researching, designing pages, using visual aids, describing). Section 2: Technical Communication Applications (7 chapters on sets of instructions, informal reports and email, developing...... websites/using social media, formal reports, recommendation and feasibility reports, proposals, user manuals). Section 3: Professional Communication (2 chapters and 2 appendices on presentations, job application materials, brief handbook for tech writers, documenting sources)....

  9. Technical Report Writing Today

    DEFF Research Database (Denmark)

    Riordan, Daniel G.

    2014-01-01

    Section 1: Technical Communication Basics (8 chapters on tech com, audiences, tech com process, tech com style, researching, designing pages, using visual aids, describing). Section 2: Technical Communication Applications (7 chapters on sets of instructions, informal reports and email, developing...... websites/using social media, formal reports, recommendation and feasibility reports, proposals, user manuals). Section 3: Professional Communication (2 chapters and 2 appendices on presentations, job application materials, brief handbook for tech writers, documenting sources)....

  10. Technical evaluation report on the Third 10-year Interval Inservice Inspection Program Plan: Florida Power and Light Company, Turkey Point Nuclear Power Plant, Units 3 and 4 (Docket Numbers 50-250 and 50-251)

    Energy Technology Data Exchange (ETDEWEB)

    Brown, B.W.; Feige, E.J.; Galbraith, S.G.; Porter, A.M.

    1995-02-01

    This report presents the results of the evaluation of the Turkey Point Nuclear Power Plant, Units 3 and 4, Third 10-Year Interval Inservice Inspection Program Plan, Revision 0, submitted September 9, 1993, including the requests for relief from the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section XI, requirements that the licensee has determined to be impractical. The Turkey Point Nuclear Power Plant, Units 3 and 4, Third 10-Year Interval Inservice Inspection Program Plan is evaluated in Section 2 of this report. The inservice inspection (ISI) program plan is evaluated for (a) compliance with the appropriate edition/addenda of Section XI, (b) acceptability of the examination sample, (c) correctness of the application of system or component examination exclusion criteria, and (d) compliance with ISI-related commitments identified during previous Nuclear Regulatory Commission (NRC) reviews. The requests for relief are evaluated in Section 3 of this report.

  11. PTI TECHNICAL ASSISTANCE TO REBUILD AMERICA

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2002-04-01

    Public Technology Inc. (PTI) engaged in a cooperative agreement, DE-FC26-01NT41107, with the US Department of Energy's (DOE) Rebuild America Program to provide energy efficiency and energy conservation technical assistance to local governments across the United States. The first year of the cooperative agreement dated from April 2, 2001 to April 1, 2002, at a funding level of $375,000. This technical report covers the period of October 2001--March 2002. PTI appreciates the support that it has received from Rebuild America and plans to continue, with DOE and Rebuild America support, to serve in a strategic capacity, lending the technical experience of its staff and that of the Energy Task Force on approaches to increasing program efficiencies, furthering program development, and coordinating information sharing to help ensure that energy programs are responsive to the needs of local governments.

  12. 78 FR 27963 - Reliability Technical Conference; Notice of Technical Conference

    Science.gov (United States)

    2013-05-13

    ... Energy Regulatory Commission Reliability Technical Conference; Notice of Technical Conference Take notice that the Federal Energy Regulatory Commission will hold a Technical Conference on Tuesday, July 9, 2013... to the webcast. The Capitol Connection provides technical support for webcasts and offers the...

  13. Scientific and Technical Information: Impetus for Development in Southeast Asia.

    Science.gov (United States)

    Abdullah, Szarina

    1995-01-01

    Analysis of trends in scientific publications of Southeast Asian countries revealed a high degree of knowledge dependence on English publications from the United States and the United Kingdom. Discusses the use of scientific and technical information as a catalyst to accelerate knowledge production, distribution, and industrialization in Southeast…

  14. 76 FR 22924 - Records Schedules; Availability and Request for Comments

    Science.gov (United States)

    2011-04-25

    ... records when no longer needed for current Government business. They authorize the preservation of records... its business. Some schedules are comprehensive and cover all the records of an agency or one of its... United States Courts, United States Bankruptcy Courts (N1-578-11-1, 11 items, 2 temporary items). Non...

  15. 丁辛醇罐区尾气焚烧系统的应用及技术改造%Butyl Octanol Unit Tank Tail Gas Incineration Application and Technical Innovation System

    Institute of Scientific and Technical Information of China (English)

    王猛; 姜波; 杨留龙; 徐自奇

    2014-01-01

    Butyl octanol project of Sichuan Petrochemical Company built a new set of low pressure flare as the tank tail gas safety vent facilities , new low pressure flare production equipment to ensure normal or accidental discharge to the timely , safe, reliable emission combustion in low pressure flare , and met the relevant national standards and environmental protection requirements of the current.Its structure , technical characteristics , and process were briefly reviewed , in the actual use of the process , there were still some problems.The problems and solution methods were described.%中石油四川石化有限公司丁辛醇项目新建一套低压火炬作为其罐区尾气安全放空设施,新建低压火炬保证生产装置正常或事故排放时能够及时、安全、可靠地在低压火炬中排放燃烧,并满足国家现行的有关标准和环保要求。现对其构造、技术特点、流程作一简要叙述;在实际使用过程中还存在一些问题,本文对这些问题及其技术解决方法作一论述。

  16. The NASA Technical Report Server

    Science.gov (United States)

    Nelson, Michael L.; Gottlich, Gretchen L.; Bianco, David J.; Paulson, Sharon S.; Binkley, Robert L.; Kellogg, Yvonne D.; Beaumont, Chris J.; Schmunk, Robert B.; Kurtz, Michael J.; Accomazzi, Alberto

    1995-01-01

    The National Aeronautics and Space Act of 1958 established NASA and charged it to "provide for the widest practicable and appropriate dissemination of information concerning its activities and the results thereof." The search for innovative methods to distribute NASA's information lead a grass-roots team to create the NASA Technical Report Server (NTRS), which uses the World Wide Web and other popular Internet-based information systems as search engines. The NTRS is an inter-center effort which provides uniform access to various distributed publication servers residing on the Internet. Users have immediate desktop access to technical publications from NASA centers and institutes. The NTRS is comprised of several units, some constructed especially for inclusion in NTRS, and others that are existing NASA publication services that NTRS reuses. This paper presents the NTRS architecture, usage metrics, and the lessons learned while implementing and maintaining the service. The NTRS is largely constructed with freely available software running on existing hardware. NTRS builds upon existing hardware and software, and the resulting additional exposure for the body of literature contained ensures that NASA's institutional knowledge base will continue to receive the widest practicable and appropriate dissemination.

  17. FAO Technical meeting on prebiotics.

    Science.gov (United States)

    Pineiro, Maya; Asp, Nils-Georg; Reid, Gregor; Macfarlane, Sandra; Morelli, Lorenzo; Brunser, Oscar; Tuohy, Kieran

    2008-09-01

    Recognizing the possible beneficial effect of prebiotics in food, the Food and Agriculture Organization of the United Nations (FAO) convened a Technical meeting to start work on the evaluation of the functional and health properties of prebiotics. A group of international experts agreed on guidelines, recommended criteria, and methodology for conducting a systematic approach for the evaluation of prebiotics leading to its safe use in food. It was recommended that a full expert consultation be convened under the auspices of FAO. This work provides governments, industry, and consumers with scientific advice in relation to functional and health aspects of prebiotics and general guidance for the assessment of prebiotics in relation to their nutritional properties or safety. These guidelines may also be used by Member Countries and Codex Alimentarius to identify and define what data need to be available to accurately substantiate health and nutrition claims.

  18. Privacy, confidentiality, and electronic medical records.

    Science.gov (United States)

    Barrows, R C; Clayton, P D

    1996-01-01

    The enhanced availability of health information in an electronic format is strategic for industry-wide efforts to improve the quality and reduce the cost of health care, yet it brings a concomitant concern of greater risk for loss of privacy among health care participants. The authors review the conflicting goals of accessibility and security for electronic medical records and discuss nontechnical and technical aspects that constitute a reasonable security solution. It is argued that with guiding policy and current technology, an electronic medical record may offer better security than a traditional paper record. PMID:8653450

  19. Realization of a technical and economic referential of units of organic waste processing by methanization with and without biogas valorization. Study report; Realisation d'un referentiel technique et economique d'unites de traitement de dechets organiques par methanisation avec et sans valorisation du biogaz. Rapport d'etude

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Based on a literature survey and on the analysis of results obtained in operating installations in different countries (Germany, Denmark, France, Netherlands, and Switzerland), this study concerns the methanization of different substrates: domestic wastes, sludge from sewage processing plants, industrial wastes and effluents, agricultural wastes and effluents. This synthetic report describes the current status of methanization in terms of regulatory framework (for renewable energies, and for waste management, digestion residues and compost valorization in Europe and in the studied countries), and in terms of actual production and variety of base products. It gives an overview of the available technical solutions, of the products they use, and of the associated investment costs. These techniques are: completely stirred tank reactor (SCTR), upflow anaerobic sludge blanket (UASB), internal circulation (IC), 'piston', batch, percolation, contact, fluidized bed, and anaerobic filter. It reports a synthesis of answers given to a questionnaire about technical and economic aspects

  20. Good night, squashbite: a 'how to' paper on better wax occlusal records.

    Science.gov (United States)

    Shargill, Inderjit; Ashley, Martin

    2006-12-01

    During the technical stages of dental treatment, a dental technician may only be able to unite a set of dental casts in a 'best-guess' relationship, unless they are either able to examine the patient themselves, or are given further information about the occlusal position chosen during the clinical procedure. The most common method for this is to use some form of occlusal record, which can be created from a variety of techniques and materials, such as either one of the dental waxes or one of the more recently introduced syringable materials. This paper describes a better technique for using dental wax to make occlusal records. The 'squashbite' technique has no place in clinical dentistry for those attempting to obtain accurate results.

  1. Formative evaluation of a telemedicine model for delivering clinical neurophysiology services part I: Utility, technical performance and service provider perspective

    Directory of Open Access Journals (Sweden)

    Breen Patricia

    2010-09-01

    Full Text Available Abstract Background Formative evaluation is conducted in the early stages of system implementation to assess how it works in practice and to identify opportunities for improving technical and process performance. A formative evaluation of a teleneurophysiology service was conducted to examine its technical and sociological dimensions. Methods A teleneurophysiology service providing routine EEG investigation was established. Service use, technical performance and satisfaction of clinical neurophysiology personnel were assessed qualitatively and quantitatively. These were contrasted with a previously reported analysis of the need for teleneurophysiology, and examination of expectation and satisfaction with clinical neurophysiology services in Ireland. A preliminary cost-benefit analysis was also conducted. Results Over the course of 40 clinical sessions during 20 weeks, 142 EEG investigations were recorded and stored on a file server at a satellite centre which was 130 miles away from the host clinical neurophysiology department. Using a virtual private network, the EEGs were accessed by a consultant neurophysiologist at the host centre for interpretation. The model resulted in a 5-fold increase in access to EEG services as well as reducing average waiting times for investigation by a half. Technically the model worked well, although a temporary loss of virtual private network connectivity highlighted the need for clarity in terms of responsibility for troubleshooting and repair of equipment problems. Referral quality, communication between host and satellite centres, quality of EEG recordings, and ease of EEG review and reporting indicated that appropriate organisational processes were adopted by the service. Compared to traditional CN service delivery, the teleneurophysiology model resulted in a comparable unit cost per EEG. Conclusion Observations suggest that when traditional organisational boundaries are crossed challenges associated with the

  2. Religious Support to Corps Nondivisional Units

    Science.gov (United States)

    1991-01-01

    unit. This may be properly called technical coordination of GRS without technical control. This relationship may be seen in Figure 14. 00 TECNICA CONTROL...Team building 1 Dramatic increase of MTs to supervise in 1 combat Leave garrison mentality 1 Survivability 1 Interaction with other staff sections 1

  3. 美俄下一代战略轰炸机技术方案分析%The Technical Conceptions of Next Generation Strategic Bombers of United States and Russia

    Institute of Scientific and Technical Information of China (English)

    许云峰; 郭圣洪

    2015-01-01

    The major drivers and the operations requirements for the development of new strategic bombers were analyzed according to the discuss procedure of America and Russia. Although the new strategic bombers of America and Russia both adopt a tall ess conifguration for subsonic operation and would be a multipurpose weapon platform, they have different considerations for their future operations, with America’s new bomber suitable for network centric warfare whereas Russia’s new bomber depend heavily on its stealthy. The technical conception of America and Russia strategic bomber was selected according to its individual military strategy, technological level, economic strength and industrial infrastructure.%根据美国和俄罗斯新一代战略轰炸机的论证过程,分析了驱动战略轰炸机不断发展的主要因素和新一代战略轰炸机的作战需求。美俄新一代战略轰炸机都采用了亚声速飞翼布局的多用途武器运载平台,但其设计考虑有所不同,美国突出网络中心战能力,而俄罗斯强调飞机自身的隐身能力。美国和俄罗斯战略轰炸机技术方案的选择均有其军事战略、技术水平、经济实力、工业基础等方面的现实考虑。

  4. Technical Assistance to Developers

    Energy Technology Data Exchange (ETDEWEB)

    Rockward, Tommy [Los Alamos National Laboratory; Borup, Rodney L. [Los Alamos National Laboratory; Garzon, Fernando H. [Los Alamos National Laboratory; Mukundan, Rangachary [Los Alamos National Laboratory; Spernjak, Dusan [Los Alamos National Laboratory

    2012-07-17

    This task supports the allowance of technical assistance to fuel-cell component and system developers as directed by the DOE. This task includes testing of novel materials and participation in the further development and validation of single cell test protocols. This task also covers technical assistance to DOE Working Groups, the U.S. Council for Automotive Research (USCAR) and the USCAR/DOE Driving Research and Innovation for Vehicle efficiency and Energy sustainability (U.S. Drive) Fuel Cell Technology Team. Assistance includes technical validation of new fuel cell materials and methods, single cell fuel cell testing to support the development of targets and test protocols, and regular advisory participation in other working groups and reviews. This assistance is made available to PEM fuel cell developers by request and DOE Approval. The objectives are to: (1) Support technically, as directed by DOE, fuel cell component and system developers; (2) Assess fuel cell materials and components and give feedback to developers; (3) Assist the DOE Durability Working Group with the development of various new material durability Testing protocols; and (4) Provide support to the U.S. Council for Automotive Research (USCAR) and the USCAR/DOE Fuel Cell Technology Team. FY2012 specific technical objectives are: (1) Evaluate novel MPL materials; (2) Develop of startup/ shutdown protocol; (3) Test the impact of hydrophobic treatment on graphite bi-polar plates; (4) Perform complete diagnostics on metal bi-polar plates for corrosion; and (5) Participate and lead efforts in the DOE Working Groups.

  5. Death in the United States, 2011

    Science.gov (United States)

    ... Order from the National Technical Information Service NCHS Death in the United States, 2011 Recommend on Facebook ... 2011 SOURCE: National Vital Statistics System, Mortality. Do death rates vary by state? States experience different mortality ...

  6. Fuel Element Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Burley, H.H. [ed.

    1956-08-01

    It is the purpose of the Fuel Element Technical Manual to Provide a single document describing the fabrication processes used in the manufacture of the fuel element as well as the technical bases for these processes. The manual will be instrumental in the indoctrination of personnel new to the field and will provide a single data reference for all personnel involved in the design or manufacture of the fuel element. The material contained in this manual was assembled by members of the Engineering Department and the Manufacturing Department at the Hanford Atomic Products Operation between the dates October, 1955 and June, 1956. Arrangement of the manual. The manual is divided into six parts: Part I--introduction; Part II--technical bases; Part III--process; Part IV--plant and equipment; Part V--process control and improvement; and VI--safety.

  7. Technical training - places available

    CERN Multimedia

    2012-01-01

    If you would like more information on a course, or for any other inquiry/suggestions, please contact Technical.Training@cern.ch Valeria Perez Reale, Learning Specialist, Technical Programme Coordinator (Tel.: 62424) Eva Stern and Elise Romero, Technical Training Administration (Tel.: 74924) HR Department »Electronics design Next Session Duration Language Availability Comprehensive VHDL for FPGA Design 08-Oct-12 to 12-Oct-12 5 days English 3 places available Foundations of Electromagnetism and Magnet Design (EMAG) 14-Nov-12 to 27-Nov-12 6 days English 20 places available Impacts de la suppression du plomb (RoHS) en électronique 26-Oct-12 to 26-Oct-12 8 hours French 15 places available Introduction to VHDL 10-Oct-12 to 11-Oct-12 2 days English 7 places available LabVIEW Real Time and FPGA 13-Nov-12 to 16-Nov-12 5 days French 5 places available »Mechanical design Next Se...

  8. Technical training: places available

    CERN Multimedia

    2013-01-01

    If you would like more information on a course, or for any other inquiry/suggestions, please contact Technical.Training@cern.ch Valeria Perez Reale, Learning Specialist, Technical Programme Coordinator (Tel.: 62424) Eva Stern and Elise Romero, Technical Training Administration (Tel.: 74924)   Electronics design Next Session Duration Language Introduction to VHDL 21-Feb-13 to 22-Feb-13 2 days English Mechanical design Next Session Duration Language ANSYS - Introduction à ANSYS Mechanical APDL 04-Feb-13 to 07-Feb-13 4 days English Applications de la cotation fonctionnelle et du langage ISO 06-Feb-13 to 08-Feb-13 2 days 4 hours French CATIA V5 – Surfacique 14-Jan-13 to 15-Jan-13 2 days French Office software Next Session Duration Language ACCESS 2010 - niveau 2 : ECDL 06-Feb-13 to 07-Feb-13 2 days French Dreamweaver CS3 - Niveau 1 14-Jan-13 to 15-Jan-13 2 d...

  9. Windows 10 Technical Preview

    OpenAIRE

    Jyväsjärvi, Teppo

    2015-01-01

    Tässä opinnäytetyössä tutustaan uuden kesällä 2015 virallisesti julkaistavan Windows 10 -käyttöjärjestelmän Technical Preview -kehitysversioon. Ensimmäinen Technical Preview -versio julkaistiin syksyllä 2014. Opinnäytetyössä tutustaan Windows 10:n uusin ominaisuuksiin ja tehdään vertailua aiemman Windows 8.1 -version kanssa. Työssä Windows 10 Technical Preview asennetaan virtuaalikoneelle, käydään läpi asennuksen eri vaiheet sekä suurimmat muutokset käyttöliittymässä ja sovelluksissa. Op...

  10. Technical training - Places available

    CERN Multimedia

    2012-01-01

    If you would like more information on a course, or for any other inquiry/suggestions, please contact Technical.Training@cern.ch Valeria Perez Reale, Learning Specialist, Technical Programme Coordinator (Tel.: 62424) Eva Stern and Elise Romero, Technical Training Administration (Tel.: 74924)   Electronics design Next Session Duration Language Availability Certified LabVIEW Associate Developer (CLAD) 06-Dec-12 to 06-Dec-12 1 hour English One more place available Compatibilité électromagnetique (CEM): Applications 23-Nov-12 to 23-Nov-12 3.5 hours English 3 places available Compatibilité électromagnétique (CEM): Introduction 23-Nov-12 to 23-Nov-12 3 hours English 43 places available Effets des Radiations sur les composants et systèmes électroniques 11-Dec-12 to 12-Dec-12 1 day 4 hours French 9 places available LabVIEW for beginners ...

  11. Transformation of technical infrastructure

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev

    The scope of the project is to investigate the possibillities of - and the barriers for a transformation of technical infrastructure conserning energy, water and waste. It focus on urban ecology as a transformation strategy. The theoretical background of the project is theories about infrastructure......, the evolution of large technological systems and theories about organisational and technological transformationprocesses. The empirical work consist of three analysis at three different levels: socio-technical descriptions of each sector, an envestigation of one municipality and envestigations of one workshop...

  12. CERN Technical Training : Vista !

    CERN Multimedia

    HR Department

    2008-01-01

    You are running Vista on your new PC – or are planning to install it? The Technical Training service is organizing a half-day training course on the new features of the VISTA operating system. This course introduces the new interfaces and presents the new functionalities for people who are experienced in the use of Windows XP. The next bilingual sessions of this course will take place on 12 December 2008 and 30 January 2009. Register using our catalogue: http://cta.cern.ch/cta2/f?p=110:9 or contact us with your questions/comments at mailto:Technical.Training@cern.ch

  13. CERN Technical Training : Vista !

    CERN Multimedia

    HR Department

    2008-01-01

    Are you running Vista on your new PC – or are you planning to install it? The Technical Training service is organizing a half-day training course on the new features of the VISTA operating system. This course introduces the new interfaces and presents the new functionalities for people who are experienced in the use of Windows XP. The next bilingual sessions of this course will take place on 12 December 2008 and 30 January 2009. Register using our catalogue: http://cta.cern.ch/cta2/f?p=110:9 or contact us with your questions/comments at mailto:Technical.Training@cern.ch

  14. CERN Technical Training : Vista !

    CERN Multimedia

    HR Department

    2008-01-01

    Are you running Vista on your new PC – or are planning to install it? The Technical Training service is organizing a half-day training course on the new features of the VISTA operating system. This course introduces the new interfaces and presents the new functionalities for people who are experienced in the use of Windows XP. The next bilingual sessions of this course will take place on 12 December 2008 and 30 January 2009. Register using our catalogue: http://cta.cern.ch/cta2/f?p=110:9 or contact us with your questions/comments at Technical.Training@cern.ch

  15. CERN Technical Training : Vista !

    CERN Multimedia

    HR Department

    2009-01-01

    Are you running Vista on your new PC – or are you planning to install it? The Technical Training service is organizing a half-day training course on the new features of the VISTA operating system. This course introduces the new interfaces and presents the new functionalities for people who are experienced in the use of Windows XP. The next bilingual session of this course will take place on 30 January 2009. Register using our catalogue: http://cta.cern.ch/cta2/f?p=110:9 or contact us with your questions/comments at mailto:Technical.Training@cern.ch

  16. CERN Technical Training : Vista !

    CERN Multimedia

    HR Department

    2008-01-01

    You are running Vista on your new PC – or are planning to install it? The Technical Training service is organizing a half-day training on the new features of the VISTA operating system. This course introduces the new interfaces and presents the new functionalities for people who are experienced using Windows XP. The next bilingual sessions of this course will take place on December 12, 2008 and January 30, 2009. Register using our catalogue : http://cta.cern.ch/cta2/f?p=110:9 or contact us with your questions/comments at Technical.Training@cern.ch

  17. Action potential waveform variability limits multi-unit separation in freely behaving rats.

    Directory of Open Access Journals (Sweden)

    Peter Stratton

    Full Text Available Extracellular multi-unit recording is a widely used technique to study spontaneous and evoked neuronal activity in awake behaving animals. These recordings are done using either single-wire or multiwire electrodes such as tetrodes. In this study we have tested the ability of single-wire electrodes to discriminate activity from multiple neurons under conditions of varying noise and neuronal cell density. Using extracellular single-unit recording, coupled with iontophoresis to drive cell activity across a wide dynamic range, we studied spike waveform variability, and explored systematic differences in single-unit spike waveform within and between brain regions as well as the influence of signal-to-noise ratio (SNR on the similarity of spike waveforms. We also modelled spike misclassification for a range of cell densities based on neuronal recordings obtained at different SNRs. Modelling predictions were confirmed by classifying spike waveforms from multiple cells with various SNRs using a leading commercial spike-sorting system. Our results show that for single-wire recordings, multiple units can only be reliably distinguished under conditions of high recording SNR (≥ 4 and low neuronal density (≈ 20,000/ mm(3. Physiological and behavioural changes, as well as technical limitations typical of awake animal preparations, reduce the accuracy of single-channel spike classification, resulting in serious classification errors. For SNR <4, the probability of misclassifying spikes approaches 100% in many cases. Our results suggest that in studies where the SNR is low or neuronal density is high, separation of distinct units needs to be evaluated with great caution.

  18. 10 CFR 9.21 - Publicly available records.

    Science.gov (United States)

    2010-01-01

    ... available records. (a) Single copies of NRC publications in the NUREG series, NRC Regulatory Guides, and..., Documents Made Publicly Available (NUREG-0540) after March 1999. (d) The published versions of the records... Regulatory Issuances, NUREG-0750, for purchase through the National Technical Information Service....

  19. 10 CFR 1303.115 - Preservation of records.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Preservation of records. 1303.115 Section 1303.115 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PUBLIC INFORMATION AND REQUESTS § 1303.115 Preservation of records. The Board shall preserve all correspondence pertaining to the requests that it receives under...

  20. 32 CFR 1701.5 - Collection and maintenance of records.

    Science.gov (United States)

    2010-07-01

    ... NATIONAL INTELLIGENCE ADMINISTRATION OF RECORDS UNDER THE PRIVACY ACT OF 1974 Protection of Privacy and... maintain a record which describes how an individual exercises rights guaranteed by the First Amendment...) Each ODNI component shall implement administrative, physical and technical controls to...

  1. 77 FR 24925 - Privacy Act of 1974; System of Records

    Science.gov (United States)

    2012-04-26

    ... a rigorous peer- review involving technical experts (scientists, educators, farmers, engineers, and... individuals regarding the uses to which their records are put, and to assist individuals to more easily find... unique State identifying number or last name of the individual. Safeguards: Records in this system...

  2. 催化裂化装置德尔塔型余热锅炉技术改造%Technical Transformation of DELTAK Waste Heat Boiler for Catalytic Cracking Unit

    Institute of Scientific and Technical Information of China (English)

    叶发强; 樊帆; 郑军如; 李传凯

    2016-01-01

    When the waste heat boiler which is designed by DELTAK,Inc.and equipped with FCC device in a refinery was operating,there were some problems,such as evaporating section tube bank cavitation and leakage,economizer tube bank and elbows corrosion and leakage at the dew point temperature,too high exhaust gas temperature,high furnace pressure caused by heavy dust on heating surface.On the basis of steel structure frames and space of old heating surface e-quipment,we carried out technical transformation through changing the evaporating section into a forced circulation mode,changing the heat exchanger components of economizer and improving technology and processes,adding long nozzle hole shock wave soot blower,etc.After the trans-formation,the amount of boiler steam production increased from 16.4 t/h to 23.57 t/h,operation cycle was over 1 a,the exhaust temperature decreased from over 240 ℃to 170~180 ℃.The pro-j ect achieved good economic and social benefits and accumulated experience for the similar Deltak-type waste heat boiler transformation.%某炼油厂催化裂化装置配套的由美国德尔塔公司设计的余热锅炉运行时,存在蒸发段管束气蚀泄漏、省煤器管束弯头露点腐蚀泄漏、锅炉排烟温度过高、受热面积灰严重导致炉膛压力偏高等问题。在利旧原受热面设备钢结构框架的基础上,利用原受热面布置空间,采取了蒸发段改为强制循环方式、更换省煤器换热元件和工艺流程、增设长喷管多孔激波吹灰器等技术进行改造,改造之后余热锅炉蒸汽产量由16.4 t/h上升到23.57 t/h、运行周期延长至1 a以上、排烟温度由240℃以上下降至170~180℃,取得了良好的经济效益和社会效益,为类似德尔塔型余热锅炉改造积累了经验。

  3. PISA 2012 Technical Report

    Science.gov (United States)

    OECD Publishing, 2014

    2014-01-01

    The "PISA 2012 Technical Report" describes the methodology underlying the PISA 2012 survey, which tested 15-year-olds' competencies in mathematics, reading and science and, in some countries, problem solving and financial literacy. It examines the design and implementation of the project at a level of detail that allows researchers to…

  4. Routledge French technical dictionary

    CERN Document Server

    1994-01-01

    The French-English volume of this highly acclaimed set consists of some 100,000 keywords in both French and English, drawn from the whole range of modern applied science and technical terminology. Covers over 70 subject areas, from engineering and chemistry to packaging, transportation, data processing and much more.

  5. Technical Due Diligence

    DEFF Research Database (Denmark)

    Jensen, Per Anker; Varano, Mattia

    2011-01-01

    Technical Due Diligence (TDD) as an evaluation of the performance of constructed facilities has become an important new field of practice for consultants. Before the financial crisis started in autumn 2008 it represented the fastest growing activity in some consulting companies. TDD is mostly car...

  6. CATV Technical Papers.

    Science.gov (United States)

    National Cable Television Association, Inc., Washington, DC.

    Complete technical papers of the 1977 National Cable Television Association Convention are included in this report. Twenty-two of 32 papers and two abstracts cover the topics of advanced cable television techniques, human reactions to television picture impairment, special displays and services, protection from theft of service, everyday…

  7. Technical Training: Places available

    CERN Multimedia

    Monique Duval

    2005-01-01

    The number of places available may vary. Please check our Web site to find out the current availability. Places are available on the following courses: LabVIEW Migration 6 to 7: 14.6.2005 (1 day) IT3T/1 - Read your mail and more with Outlook 2003 : 14.6.2005 (IT Technical Training Tutorial, free of charge) IT3T/2 - Creating, managing and using distribution lists with Simba2 : 16.6.2005 (IT Technical Training Tutorial, free of charge) FrontPage 2003 - niveau 2 : 16 & 17.6.2005 (2 jours) size="2">(1journée) Hands-on Introduction to Python Programming: 28 - 30.6.2005 (3 days) Introduction to ANSYS: 21 - 24.6.2005 (4 days) IT3T/3 - Working remotely with Windows XP: 28.6.2005 (IT Technical Training Tutorial, free of charge) IT3T/4 - Editing Websites with Frontpage 2003: 30.6.2005 (IT Technical Training Tutorial, free of charge) LabVIEW base 1 : 4 - 6.7.2005 (3 jours) LabVIEW Basics 2: AutoCorrect, Find/Replace) : 4.7.2005 (afternoon) WORD 2003 (Shor...

  8. Technical Training: Places available

    CERN Multimedia

    Monique Duval

    2005-01-01

    The number of places available may vary. Please check our Web site to find out the current availability. Places are available on the following courses: LabVIEW Real-Time (F) : 7 - 9.6.2005 (3 jours) LabVIEW Migration 6 to 7: 14.6.2005 (1 day) IT3T/1 - Read your mail and more with Outlook 2003 : 14.6.2005 (IT Technical Training Tutorial, free of charge) IT3T/2 - Creating, managing and using distribution lists with Simba2 : 16.6.2005 (IT Technical Training Tutorial, free of charge) FrontPage 2003 - niveau 2 : 16 & 17.6.2005 (2 jours) Utilisation de fichiers PDF avec ACROBAT 6.0 : 20.6.2005 (1journée) Introduction to ANSYS: 21 - 24.6.2005 (4 days) IT3T/3 - Working remotely with Windows XP : 28.6.2005 (IT Technical Training Tutorial, free of charge) IT3T/4 - Editing Websites with Frontpage 2003 : 30.6.2005 (IT Technical Training Tutorial, free of charge) WORD 2003 (Short Course I) - HowTo... Work with repetitive tasks /AutoText, AutoFormat, AutoC...

  9. Improved technical specifications

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, D.R.

    1994-12-31

    Improved technical specifications for nuclear power plants are outlined. The objectives of this work are to improve safety, provide a clearer understanding of safety significance, and ease NRC and industry administrative burdens. Line item improvements, bases, and implementation of the specifications are discussed.

  10. Materials Technical Team Roadmap

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-08-01

    Roadmap identifying the efforts of the Materials Technical Team (MTT) to focus primarily on reducing the mass of structural systems such as the body and chassis in light-duty vehicles (including passenger cars and light trucks) which enables improved vehicle efficiency regardless of the vehicle size or propulsion system employed.

  11. 自升式钻井平台冲桩系统技术分析及优化方案%Technical Analysis and Optimizing Solution on Leg Jetting System for Jack Up Drilling Unit

    Institute of Scientific and Technical Information of China (English)

    蔡胜利; 张福; 冯利杰; 杜渊; 赵建帮

    2012-01-01

    Considering the fact that the current Jetting System on Jack-Up Drilling Unit cannot function well in assisting Leg Pulling-out on operation site, comparison and analysis were made for several systems' different features,advantages and disadvantages. A more reasonable engineering concept was proposed,and an optimizing solution and development proposal were brought forward for future Leg Jetting System, by which the system to realize its operation purpose was enabled efficiently.%现有自升式钻井平台的冲桩系统在作业地不能很好地发挥其辅助拔桩功能.对比分析几套典型冲桩系统的结构特点及优缺点,提出冲桩系统的优化方案和发展建议,使该系统能够高效地完成其正常的作业功能.

  12. Mecaster batnensis (Coquand, 1862), a late Cenomanian echinoid from New Mexico, with a compilation of Late Cretaceous echinoid records in the Western Interior of the United States and Canada

    Science.gov (United States)

    Hook, Stephen C.; Cobban, William A.

    2017-03-01

    Echinoids are rare in the Upper Cretaceous of the Western Interior, where fewer than 60 unique occurrences are known to date, most of these represented by only a few tests or isolated spines. A notable exception is the Carthage coal field (Socorro County, New Mexico), where more than 200 specimens of Mecaster batnensis, previously referred to as Hemiaster jacksoni Maury, 1925, have been collected from the basal Bridge Creek Limestone Beds of the Tokay Tongue of the Mancos Shale. Prolific occurrences from the same beds are known from elsewhere in west-central and southwest New Mexico. Recorded originally from the Upper Cretaceous of Algeria, M. batnensis is a small- to medium-sized, irregular echinoid that is confined to the upper Cenomanian Euomphaloceras septemseriatum Zone in New Mexico. Measurements on 169 well-preserved specimens from two localities in New Mexico document a species that is, on average, 21.0 mm long, 19.8 mm wide, and 15.1 mm tall, yielding a width/length ratio of 0.94 and a height/length ratio of 0.72. Graphs plotting width against length and height against length are strongly linear. The Western Interior echinoid record spans the entire Late Cretaceous, although there are no records from rocks of Santonian age. Localities are spread from New Mexico on the south to Alberta on the north. Preservation ranges from coarse internal molds in high-energy sandstones to original tests in low-energy limestones.

  13. Trip Report United Arab Emirates

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, K; Rodgers, A

    2004-10-06

    Keith Nakanishi and Arthur Rodgers traveled to the United Arab Emirates in February, 2004 to continue an on-going technical collaboration with UAE University and to service the two temporary LLNL seismic stations. Nakanishi and Rodgers then participated in the Gulf Seismic Forum, which was organized by LLNL and sponsored by the University of Sharjah.

  14. Presidential Electronic Records Library

    Data.gov (United States)

    National Archives and Records Administration — PERL (Presidential Electronic Records Library) used to ingest and provide internal access to the Presidential electronic Records of the Reagan, Bush, and Clinton...

  15. UARS spacecraft recorder

    Science.gov (United States)

    1987-01-01

    The objective was the design, development, and fabrication of UARS spacecraft recorders. The UARS recorder is a tailored configuration of the RCA Standard Tape recorder STR-108. The specifications and requirements are reviewed.

  16. CMS Records Schedule

    Data.gov (United States)

    U.S. Department of Health & Human Services — The CMS Records Schedule provides disposition authorizations approved by the National Archives and Records Administration (NARA) for CMS program-related records...

  17. Digital Audio Legal Recorder

    Data.gov (United States)

    Department of Transportation — The Digital Audio Legal Recorder (DALR) provides the legal recording capability between air traffic controllers, pilots and ground-based air traffic control TRACONs...

  18. Keeping the Records Straight.

    Science.gov (United States)

    Clift, Phil; Keynes, Milton

    1982-01-01

    Guidelines are given regarding keeping and using educational records for exceptional children in Great Britain. Procedures related to anecdotal records, observation inventories, and rating scales are delineated. (CL)

  19. Technical Assistance Needs Assessments (TANAs)

    Science.gov (United States)

    The Technical Assistance Needs Assessment (TANA) is a process to identify whether a community requires additional support from EPA in order to understand technical information and have meaningful participation in the Superfund decision-making process.

  20. El Salvador - Formal Technical Education

    Data.gov (United States)

    Millennium Challenge Corporation — With a budget of nearly $20 million, the Formal Technical Education Sub-Activity was designed to strengthen technical and vocational educational institutions in the...

  1. ION-1 technical manual

    Energy Technology Data Exchange (ETDEWEB)

    Halbig, J.K.; Caine, J.C.

    1985-07-01

    The portable gamma-ray and neutron detector electronics (ION-1) gives a digital readout of the current-mode response produced by gamma rays in an ion chamber and of amplification and scaling of pulses received from a neutron detector. The primary application is the measurement of gamma-ray and neutron activity of irradiated reactor fuels stored at a reactor or at a storage pond away from a reactor. ION-1 is the first such instrument to use a design that allows communication of procedures, response, and results between instrument and inspector. It prompts the inspector through procedures, carries out programmed measurement steps, calculates results and error estimates, and performs internal diagnostic checks. This Technical Manual describes adjustment procedures and limited technical information that enable the inspector to troubleshoot at the board level. 5 figs., 10 tabs.

  2. Technical Training: Places available

    CERN Multimedia

    Monique Duval

    2005-01-01

    The number of places available may vary. Please check our Web site to find out the current availability. Places are available on the following courses: PowerPoint 2003 (F) : 25.4.2005 (1 jour) WORD 2003 - niveau 1 : 2 & 3.5.2005 (2 jours) FrontPage 2003 - niveau 1 : 9 & 10.5.2005 (2 jours) ELEC-2005 - Summer Term: System electronics for physics - Issues : 10, 12, 17, 19, 24, 26 & 31.5.2005 (7 x 2h lectures) AutoCAD 2005 - niveau 1 : 11 & 12.5.2005 (2 days) Finite State Machines in the JCOP Framework: 24 - 26.5.2005 (3 days) The Joint PVSS JCOP Framework: 30.5 - 3.6.2005 (5 days) LabVIEW Migration 6 to 7: 14.6.2005 (1 day) Introduction to ANSYS: 21 - 24.6.2005 (4 days) ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING Monique Duval 74924 technical.training@cern.ch

  3. Technical Training: Places available

    CERN Multimedia

    Monique Duval

    2004-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. The number of places available may vary. Please check our Web site to find out the current availability. Places are available in the following courses: The Joint PVSS JCOP Framework: 14 - 18.6.2004 (5 days) EXCEL 2003 - niveau 2 : 17 & 18.6.2004 (2 jours) MAGNE-04 : Magnétisme pour l'électrotechnique : 6 au 8.7.2004 (3 jours) Technical Training Monique Duval - Tel.74924 technical.training@cern.ch

  4. Independent technical review, handbook

    Energy Technology Data Exchange (ETDEWEB)

    1994-02-01

    Purpose Provide an independent engineering review of the major projects being funded by the Department of Energy, Office of Environmental Restoration and Waste Management. The independent engineering review will address questions of whether the engineering practice is sufficiently developed to a point where a major project can be executed without significant technical problems. The independent review will focus on questions related to: (1) Adequacy of development of the technical base of understanding; (2) Status of development and availability of technology among the various alternatives; (3) Status and availability of the industrial infrastructure to support project design, equipment fabrication, facility construction, and process and program/project operation; (4) Adequacy of the design effort to provide a sound foundation to support execution of project; (5) Ability of the organization to fully integrate the system, and direct, manage, and control the execution of a complex major project.

  5. Bioethics for Technical Experts

    Science.gov (United States)

    Asano, Shigetaka

    Along with rapidly expanding applications of life science and technology, technical experts have been implicated more and more often with ethical, social, and legal problems than before. It should be noted that in this background there are scientific and social uncertainty elements which are inevitable during the progress of life science in addition to the historically-established social unreliability to scientists and engineers. In order to solve these problems, therefore, we should establish the social governance with ‘relief’ and ‘reliance’ which enables for both citizens and engineers to share the awareness of the issues, to design social orders and criterions based on hypothetical sense of values for bioethics, to carry out practical use management of each subject carefully, and to improve the sense of values from hypothetical to universal. Concerning these measures, the technical experts can learn many things from the present performance in the medical field.

  6. Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Mike, J., P.E.

    2012-08-30

    The STI product is the Final Technical Report from ReliOn, Inc. for contract award DE-EE0000487: Recovery Act PEM Fuel Cell Systems Providing Emergency Reserve and Backup Power. The program covered the turnkey deployment of 431 ReliOn fuel cell systems at 189 individual sites for AT&T and PG&E with ReliOn functioning as the primary equipment supplier and the project manager. The Final Technical Report provides an executive level summary, a comparison of the actual accomplishments vs. the goals and objectives of the project, as well as a summary of the project activity from the contract award date of August 1, 2009 through the contract expiration date of December 31, 2011. Two photos are included in the body of the report which show hydrogen storage and bulk hydrogen refueling technologies developed as a result of this program.

  7. Understanding Socio Technical Modularity

    DEFF Research Database (Denmark)

    Thuesen, Christian Langhoff; Kudsk, Anders; Hvam, Lars

    2011-01-01

    Modularity has gained an increasing popularity as a central concept for exploring product structure, process structure, organization structure and supply chain structure. With the offset in system theory the predominant understanding of modularity however faces difficulties in explaining the social...... dimension of modularity like irrational behaviors, cultural differences, learning processes, social organization and institutional influences on modularity. The paper addresses this gab offering a reinterpretation of the modularity concept from a socio-technical perspective in general and Actor Network...... Theory in particular. By formulating modularity from an ANT perspective covering social, material and process aspects, the modularity of a socio-technical system can be understood as an entanglement of product, process, organizational and institutional modularity. The theoretical framework is illustrated...

  8. Manageability of Technical Innovation through Technical Property Rights

    Directory of Open Access Journals (Sweden)

    Michael Horeth

    2016-06-01

    Full Text Available The term innovation is used in many respects and has been evolving over the last decades. This paper mainly focusses on managing technical innovation and differentiates this kind of innovation from others. For managing technical innovation, this work applies technical property rights, patents and utility models. The opportunity to protect the companies’ technical knowledge legally is, apart from strategic measurements like trade secrecy, a very valuable tool to manage and commercialize innovation considering the shift from closed to rather open innovation. This paper discusses the applicability of legal protection measurements for the management of technical innovation containing a critical appraisal.

  9. Technical analysis of failure of catalyst support of reformer furnace tube of a hydrogen generation unit%制氢装置转化炉炉管催化剂支托失效分析

    Institute of Scientific and Technical Information of China (English)

    齐庆轩; 冯岩

    2012-01-01

    The damages of catalyst support of reformer furnace tubes of No. 1 hydrogen generation unit in SINOPEC Shijiazhuang Refining & Chemical Co. , Ltd. in two maintenances were introduced. The composition analysis of catalyst support, the study on the macroscopic photo, the analysis of damaged surface of catalyst support of Incoloy800H, the metallographic analysis, energy dispersion spectrum (EDS) analysis, and scanning electron microscope analysis of support' s section area as well as study on the anti-caburization performances of Cr25Ni20 and Incoloy800H materials have concluded the following: The damages of catalyst support was caused by surface carburization of catalyst support material under high temperature in the presence of hydrogen, which led to phase changes of material surface structure, material stratification, loosening and bulging of surface material structure, large amount of micro-crackings in grain boundary at surface area and eduction of large amount of carbides. All these will reduce the ductility and plasticity of material. Therefore, it is difficult for the catalyst support to restore its original state after thermal expansion, which explains why there are some bulges on the tube of failed support. The anti-carburization performance is greatly improved after application of Cr25Ni20 steel material.%对两次检修中所发现的中国石油化工股份有限公司石家庄炼化分公司l号制氢装置转化炉炉管催化剂支托出现损坏的情况做了介绍,并对两种批次的催化剂支托进行了成分分析,对使用Incoloy800H材料、损坏严重的催化剂支托表面宏观照片进行了分析,对损伤支托的横截面进行金相、电镜及能谱检验分析.通过对Cr25Ni20和lncoloy800H两种材料的抗渗碳能力的比较,得出了以下结论:催化剂支托损伤的原因是材料在含氢高温环境下发生了表面渗碳现象,直接导致材料表面组织相变、材料分层、表现材料组织疏松和隆起,

  10. 高压加氢裂化装置增产喷气燃料技术改造及实施效果%TECHNICAL REVAMPING OF HYDROCRACKING UNIT FOR INCREASING JET FUEL AND IMPLEMENTATION EFFECT

    Institute of Scientific and Technical Information of China (English)

    于会泳

    2016-01-01

    The jet fuel yield of hydrocracking unit with 2.0 Mt/a capacity of SINOPEC Yanshan Co.,using RN-32/RHC-1 composite catalyst,was only 19.35% in the first cycle. To produce more jet fuel in the second cycle,the catalyst was replaced by RN-32V/RHC-3 catalyst system,resulting in 29.71% of jet fuel,still less than the design target of 31.97%.The catalyst performance and operation calibration data were then analyzed. The results found that the main reasons for lower yield of jet fuel were the ability shortages of low pressure separation system and product fractionating tower,leading to poor operation at high conversion rate and separation effect. In view of the above analysis,the control-ling instrument of high and low pressure separation system and fractionation system tray were re-vamped. After revamping,the average yield of jet fuel reaches 30.67%,close to the design requirement.%中国石化北京燕山分公司(简称北京燕山分公司)2.0 Mt/a 高压加氢裂化装置第一生产周期采用RN-32/RHC-1组合催化剂,喷气燃料收率为19.39%,为增产喷气燃料第二生产周期更换为 RN-32V/RHC-3组合催化剂,喷气燃料收率为29.71%,提高了约10百分点,但与设计值31.97%相差较大。针对上述问题,北京燕山分公司通过对催化剂性能和装置标定数据进行分析,发现主要是因为转化深度提高后装置低压分离系统和分馏系统能力不足,无法保证装置在高转化深度下运行以及喷气燃料彻底分离。因此,确定对高低压分离系统配套仪表和分馏系统塔盘内件进行相应改造。改造后,喷气燃料平均收率为30.67%,接近设计要求,达到增产喷气燃料的目的。

  11. Percutaneous vertebroplasty: technical considerations

    Institute of Scientific and Technical Information of China (English)

    Gao-jun TENG; Shi-cheng HE

    2005-01-01

    Percutaneous vertebroplasty (PVP) is a relative new interventional technique, which is widely used in treatment of vertebral collapse caused by vertebral neoplasms and osteoporotic compression fractures. The general technical considerations of PVP techniques are discussed based on authors' experience obtained over 400 patients in the past years in this article, including preparation of PMMA, instrument of PVP, guidance and puncture approaches, and technique of the procedure, etc. The conclusion is that PVP is a safe procedure if the physicians handle it properly.

  12. Understanding Socio Technical Modularity

    DEFF Research Database (Denmark)

    Thuesen, Christian Langhoff; Kudsk, Anders; Hvam, Lars

    2011-01-01

    Modularity has gained an increasing popularity as a central concept for exploring product structure, process structure, organization structure and supply chain structure. With the offset in system theory the predominant understanding of modularity however faces difficulties in explaining the social...... Theory in particular. By formulating modularity from an ANT perspective covering social, material and process aspects, the modularity of a socio-technical system can be understood as an entanglement of product, process, organizational and institutional modularity. The theoretical framework is illustrated...

  13. Technical approach document

    Energy Technology Data Exchange (ETDEWEB)

    1989-12-01

    The Uranium Mill Tailings Radiation Control Act (UMTRCA) of 1978, Public Law 95-604 (PL95-604), grants the Secretary of Energy the authority and responsibility to perform such actions as are necessary to minimize radiation health hazards and other environmental hazards caused by inactive uranium mill sites. This Technical Approach Document (TAD) describes the general technical approaches and design criteria adopted by the US Department of Energy (DOE) in order to implement remedial action plans (RAPS) and final designs that comply with EPA standards. It does not address the technical approaches necessary for aquifer restoration at processing sites; a guidance document, currently in preparation, will describe aquifer restoration concerns and technical protocols. This document is a second revision to the original document issued in May 1986; the revision has been made in response to changes to the groundwater standards of 40 CFR 192, Subparts A--C, proposed by EPA as draft standards. New sections were added to define the design approaches and designs necessary to comply with the groundwater standards. These new sections are in addition to changes made throughout the document to reflect current procedures, especially in cover design, water resources protection, and alternate site selection; only minor revisions were made to some of the sections. Sections 3.0 is a new section defining the approach taken in the design of disposal cells; Section 4.0 has been revised to include design of vegetated covers; Section 8.0 discusses design approaches necessary for compliance with the groundwater standards; and Section 9.0 is a new section dealing with nonradiological hazardous constituents. 203 refs., 18 figs., 26 tabs.

  14. Technical training - Places available

    CERN Multimedia

    2012-01-01

    If you would like more information on a course, or for any other inquiry/suggestions, please contact Technical.Training@cern.ch Valeria Perez Reale, Learning Specialist, Technical Programme Coordinator (Tel.: 62424) Eva Stern and Elise Romero, Technical Training Administration (Tel.: 74924) HR Department Electronic Design Next Session Duration Language Availability Comprehensive VHDL for FPGA Design 08-Oct-12 to 12-Oct-12 5 days English 4 places Electrostatique / Protection ESD 28-Sep-12 to 28-Sep-12 3 hours French 25 places Impacts de la suppression du plomb (RoHS) en électronique 26-Oct-12 to 26-Oct-12 8 hours French 14 places Introduction to VHDL 10-Oct-12 to 11-Oct-12 2 days English 9 places LabVIEW Real Time and FPGA 13-Nov-12 to 16-Nov-12 5 days French 5 places LabVIEW for Experts 24-Sep-12 to 28-Sep-12 5 days English 6 places LabVIEW for beginners 15-Oct-12 to 17-...

  15. New challenges for Sportis Scientific Technical Journal

    Directory of Open Access Journals (Sweden)

    Víctor Arufe Giráldez

    2015-09-01

    Full Text Available In the publishing of this issue we want to advance two major events, the first of which is to inform the Sportis Magazine will from September 1, part of official scientific journal of the University of A Coruña, with this integration It aims to improve the dissemination of the journal in the most prestigious data bases of international level and contribute to the visibility of the University of A Coruña as committed to research in school sports college, psychomotor and Physical Education.The second story that we want to give is that the November 5-7 will be held at the Faculty of Education at the University of A Coruna, the V World Congress of Sports, Physical Education and Psychomotor School. You can participate by presenting a communication, poster or virtual poster, the best papers will be invited to publish their work as research article in the following issues of the magazine. Disponéis more information on the web www.sportis.es.In this third and final issue of the year, we beat record of article, in part due to the increase in the number of items received, a total of 10 works by experts and professionals from different countries will be published. Some of the issues addressed are: first aid teacher training, the attitude toward students with disabilities, futsal, using accelerometers, bodyboard training in young, innovative proposals such as the teaching unit based Hypopressive method, aquatic motor skills, study of sports organizations, studies involving different experts from different countries, analysis of skills in physical education ... Undoubtedly an interesting number to enjoy a good coffee or tea and gain greater technical and scientific knowledge.All equipment Sportis want is your pleasure this new publication and invite you to submit your work for future issues.Receive a warm greeting,Prof. Dr. Victor Arufe GiráldezChief Editor Sportis. International Journal of School Sports, Physical Education and Psychomotor

  16. Preparing Technical Workers for the New Industrial Era: The Need for a Fundamental Shift in Federal Policy toward Technical Education. Position Paper.

    Science.gov (United States)

    National Coalition for Advanced Manufacturing, Washington, DC.

    The United States will not be competitive in the global economy of the 21st century without a technically trained work force. Community colleges and secondary schools offering technical programs are becoming increasingly important to local businesses as companies rely on a combination of schools and on-the-job training to help their employees…

  17. Electronic Health Records

    Science.gov (United States)

    ... Loss Surgery? A Week of Healthy Breakfasts Shyness Electronic Health Records KidsHealth > For Teens > Electronic Health Records Print A A A What's in ... t happen overnight, they are coming. Understanding EHRs Electronic health records (EHR) — also called electronic medical records ( ...

  18. Your Medical Records

    Science.gov (United States)

    ... Surgery? A Week of Healthy Breakfasts Shyness Your Medical Records KidsHealth > For Teens > Your Medical Records A ... Records? en español Tus historias clínicas What Are Medical Records? Each time you climb up on a ...

  19. Surgical medical record

    DEFF Research Database (Denmark)

    Bulow, S.

    2008-01-01

    A medical record is presented on the basis of selected linguistic pearls collected over the years from surgical case records Udgivelsesdato: 2008/12/15......A medical record is presented on the basis of selected linguistic pearls collected over the years from surgical case records Udgivelsesdato: 2008/12/15...

  20. Electronic Health Records

    Science.gov (United States)

    ... Loss Surgery? A Week of Healthy Breakfasts Shyness Electronic Health Records KidsHealth > For Teens > Electronic Health Records A A A What's in this ... t happen overnight, they are coming. Understanding EHRs Electronic health records (EHR) — also called electronic medical records ( ...

  1. Spoken Records. Third Edition.

    Science.gov (United States)

    Roach, Helen

    Surveying 75 years of accomplishment in the field of spoken recording, this reference work critically evaluates commercially available recordings selected for excellence of execution, literary or historical merit, interest, and entertainment value. Some types of spoken records included are early recording, documentaries, lectures, interviews,…

  2. 77 FR 5865 - Privacy Act; System of Records: State-59, Refugee Case Records

    Science.gov (United States)

    2012-02-06

    ... Refugees (UNHCR); electronic files from the International Organization for Migration (IOM) with travel and..., including departure and transit formalities. (3) To the United Nations High Commissioner for Refugees (UNHCR... Act; System of Records: State-59, Refugee Case Records SUMMARY: Notice is hereby given that...

  3. Legal and technical difficulties of web archival in Singapore

    Directory of Open Access Journals (Sweden)

    Jhonny Antonio Pabón Cadavid

    2014-11-01

    Full Text Available Web Archiving in the National Library of Singapore is one of the fundamental actions to ensure the preservation of national digital heritage. By the year 2006, the National Library of Singapore (NLS has started a Web Archive initiative called Web Archive Singapore (WAS. This paper analyses the legal and technical issues that act as obstacles for the collection and management of the digital collections established through Web Archiving in Singapore. WAS lacks an adequate copyright framework for its digital records management, including long-term preservation and access. From a technical perspective we analyze the latest international developments and challenges of web archival. In both analysis legal and technical, we emphasizes on users of archives as the main leitmotif when focus on solutions. Our final recommendations and conclusions are underlined by the fact that NLS must encourage research and knowledge creation through the support of digital humanities, implementing technical and legal solutions that foster a Web Archive.

  4. Legal and technical difficulties of web archival in Singapore

    Directory of Open Access Journals (Sweden)

    Jhonny Antonio Pabón Cadavid

    2014-12-01

    Full Text Available Web Archiving in the National Library of Singapore is one of the fundamental actions to ensure the preservation of national digital heritage. By the year 2006, the National Library of Singapore (NLS has started a Web Archive initiative called Web Archive Singapore (WAS. This paper analyses the legal and technical issues that act as obstacles for the collection and management of the digital collections established through Web Archiving in Singapore. WAS lacks an adequate copyright framework for its digital records management, including long-term preservation and access. From a technical perspective we analyze the latest international developments and challenges of web archival. In both analysis legal and technical, we emphasizes on users of archives as the main leitmotif when focus on solutions. Our final recommendations and conclusions are underlined by the fact that NLS must encourage research and knowledge creation through the support of digital humanities, implementing technical and legal solutions that foster a Web Archive.

  5. 29 CFR 500.271 - Certification of official record.

    Science.gov (United States)

    2010-07-01

    ... MIGRANT AND SEASONAL AGRICULTURAL WORKER PROTECTION Administrative Proceedings Record § 500.271 Certification of official record. Upon receipt of timely notice of appeal to a United States District Court... and file with the appropriate United States District Court, a full, true, and correct copy of...

  6. 19 CFR 10.587 - Maintenance of records.

    Science.gov (United States)

    2010-04-01

    ...-United States Free Trade Agreement Import Requirements § 10.587 Maintenance of records. (a) General. An importer claiming preferential tariff treatment for a good imported into the United States under § 10.583(b..., all records and documents that the importer has demonstrating that the good qualifies for...

  7. Shaft Position Influence on Technical Characteristics of Universal Two-Stages Helical Speed Reducers

    OpenAIRE

    Мilan Rackov; Zeljko Kanovic; Sinisa Kuzmanovic; Ruzica Trbojevic

    2005-01-01

    Purchasers of speed reducers decide on buying those reducers, that can the most approximately satisfy their demands with much smaller costs. Amount of used material, ie. mass and dimensions of gear unit influences on gear units price. Mass and dimensions of gear unit, besides output torque, gear unit ratio and efficiency, are the most important parameters of technical characteristics of gear units and their quality. Centre distance and position of shafts have significant influence on output t...

  8. Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Sobecky, Patricia A; Taillefert, Martial

    2013-03-29

    This final technical report describes results and findings from a research project to examine the role of microbial phosphohydrolase enzymes in naturally occurring subsurface microorganisms for the purpose of promoting the immobilization of the radionuclide uranium through the production of insoluble uranium phosphate minerals. The research project investigated the microbial mechanisms and the physical and chemical processes promoting uranium biomineralization and sequestration in oxygenated subsurface soils. Uranium biomineralization under aerobic conditions can provide a secondary biobarrier strategy to immobilize radionuclides should the metal precipitates formed by microbial dissimilatory mechanisms remobilize due to a change in redox state.

  9. Technical barrier challenges

    Institute of Scientific and Technical Information of China (English)

    李思佳

    2014-01-01

    according to a famouse report,the foreign Technical Barriers to Trade(TBT)have some effects on the exports of the People’s Republic of China.Major findings are as follows:(1)TBT makes it more difficult for China to export;(2)TBT increases the costs of Chinese export commodities;(3)TBT causes friction and confilicts in the international trade;(4)SOME developed countries have moved their phase-outs to China and other developing countries,which have become victims of TBT.

  10. RADTRAN 6 technical manual.

    Energy Technology Data Exchange (ETDEWEB)

    Weiner, Ruth F.; Neuhauser, Karen Sieglinde; Heames, Terence John; O' Donnell, Brandon M.; Dennis, Matthew L.

    2014-01-01

    This Technical Manual contains descriptions of the calculation models and mathematical and numerical methods used in the RADTRAN 6 computer code for transportation risk and consequence assessment. The RADTRAN 6 code combines user-supplied input data with values from an internal library of physical and radiological data to calculate the expected radiological consequences and risks associated with the transportation of radioactive material. Radiological consequences and risks are estimated with numerical models of exposure pathways, receptor populations, package behavior in accidents, and accident severity and probability.

  11. RADTRAN 6 Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Weiner, Ruth F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Neuhauser, Karen Sieglinde [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Heames, Terence John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); O' Donnell, Brandon M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dennis, Matthew L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-01-01

    This Technical Manual contains descriptions of the calculation models and mathematical and numerical methods used in the RADTRAN 6 computer code for transportation risk and consequence assessment. The RADTRAN 6 code combines user-supplied input data with values from an internal library of physical and radiological data to calculate the expected radiological consequences and risks associated with the transportation of radioactive material. Radiological consequences and risks are estimated with numerical models of exposure pathways, receptor populations, package behavior in accidents, and accident severity and probability.

  12. The design and practice of giant hydro-turbine generating units of Three Gorges Project%The design and practice of giant hydro-turbine generating units of Three Gorges Project

    Institute of Scientific and Technical Information of China (English)

    Shao Jianxiong; Liu Jingwang; Yuan Dafu

    2011-01-01

    The main technical problems that should be considered in the design of hydro-turbine generating units of Three Gorges Project (TGP) are analyzed;the key technical researches performed are summarized, and the parameters of hydro-turbine generating units are optimized through the study on key technical problems. The unit operation indicates that the performance of the hydro-turbine generating units is excellent, and the units can operate in a safe, stable and highly efficient mode for a long term. Therefore, it is verified effectively that the general technical design of units is scientific and rational.

  13. Southwest Region Experiment Station - Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, A

    2011-08-19

    Southwest Technology Development Institute (SWTDI), an independent, university-based research institute, has been the operator of the Southwest Region Photovoltaic Experiment Station (SWRES) for almost 30 years. The overarching mission of SWTDI is to position PV systems and solar technologies to become cost-effective, major sources of energy for the United States. Embedded in SWTDI's general mission has been the more-focused mission of the SWRES: to provide value added technical support to the DOE Solar Energy Technologies Program (SETP) to effectively and efficiently meet the R&D needs and targets specified in the SETP Multi-Year Technical Plan. : The DOE/SETP goals of growing U.S. PV manufacturing into giga-watt capacities and seeing tera-watt-hours of solar energy production in the U.S. require an infrastructure that is under development. The staff of the SWRES has supported DOE/SETP through a coherent, integrated program to address infrastructural needs inhibiting wide-scale PV deployment in three major technical categories: specialized engineering services, workforce development, and deployment facilitation. The SWRES contract underwent three major revisions during its five year period-of- performance, but all tasks and deliverables fell within the following task areas: Task 1: PV Systems Assistance Center 1. Develop a Comprehensive multi-year plan 2. Provide technical workforce development materials and workshops for PV stakeholder groups including university, professional installers, inspectors, state energy offices, Federal agencies 3. Serve on the NABCEP exam committee 4. Provide on-demand technical PV system design reviews for U.S. PV stakeholders 5. Provide PV system field testing and instrumentation, technical outreach (including extensive support for the DOE Market Transformation program) Task 2: Design-for-Manufacture PV Systems 1. Develop and install 18 kW parking carport (cost share) and PV-thermal carport (Albuquerque) deriving and publishing

  14. Onshore industrial wind turbine locations for the United States

    Science.gov (United States)

    Diffendorfer, Jay E.; Compton, Roger; Kramer, Louisa; Ancona, Zach; Norton, Donna

    2017-01-01

    This dataset provides industrial-scale onshore wind turbine locations in the United States, corresponding facility information, and turbine technical specifications. The database has wind turbine records that have been collected, digitized, locationally verified, and internally quality controlled. Turbines from the Federal Aviation Administration Digital Obstacles File, through product release date July 22, 2013, were used as the primary source of turbine data points. The dataset was subsequently revised and reposted as described in the revision histories for the report. Verification of the turbine positions was done by visual interpretation using high-resolution aerial imagery in Environmental Systems Research Institute (Esri) ArcGIS Desktop. Turbines without Federal Aviation Administration Obstacles Repository System numbers were visually identified and point locations were added to the collection. We estimated a locational error of plus or minus 10 meters for turbine locations. Wind farm facility names were identified from publicly available facility datasets. Facility names were then used in a Web search of additional industry publications and press releases to attribute additional turbine information (such as manufacturer, model, and technical specifications of wind turbines). Wind farm facility location data from various wind and energy industry sources were used to search for and digitize turbines not in existing databases. Technical specifications for turbines were assigned based on the wind turbine make and model as described in literature, specifications listed in the Federal Aviation Administration Digital Obstacles File, and information on the turbine manufacturer’s Web site. Some facility and turbine information on make and model did not exist or was difficult to obtain. Thus, uncertainty may exist for certain turbine specifications. That uncertainty was rated and a confidence was recorded for both location and attribution data quality.

  15. Human heredity and politics: A comparative institutional study of the Eugenics Record Office at Cold Spring Harbor (United States), the Kaiser Wilhelm Institute for Anthropology, Human Heredity, and Eugenics (Germany), and the Maxim Gorky Medical Genetics Institute (USSR).

    Science.gov (United States)

    Adams, Mark B; Allen, Garland E; Weiss, Sheila Faith

    2005-01-01

    Despite the fact that much has been written in recent years about the science of heredity under the Third Reich, there is as yet no satisfying analysis of two central questions: What, if anything, was peculiarly "Nazi" about human genetics under National Socialism? How, under whatever set of causes, did at least some of Germany's most well-known and leading biomedical practioners become engaged in entgrenzte Wissenschaft (science without moral boundaries)? This paper attempts to provide some answers to these two questions comparing three institutes that studied eugenics and human heredity in the 1920s and 1930s: the Eugenics Record Office at Cold Spring Harbor, New York, directed by Charles B. Davenport; the Kaiser Wilhelm Institute for Anthropology, Human Heredity and Eugenics, in Berlin, directed by Eugen Fischer; and the Maxim Gorky Medical Genetics Institute in Moscow, directed by Solomon G. Levit. The institutes are compared on the basis of the kind and quality of their research in eugenics and medical genetics, organizational structure, leadership, patronage (private or state), and the economic-social-political context in which they functioned.

  16. The technical writer's handbook writing with style and clarity

    CERN Document Server

    Young, Matt

    2002-01-01

    "The Technical Writer's Handbook" is by a practising scientist who screens hundreds of manuscripts each year. It is directed at scientists, engineers and others who want to improve their writing and communication. It teaches that technical writing, although it has its own special requirements, is no different from ordinary writing and should be written with short, clear sentences and in the active voice. Divided into two parts, the first part is an introduction to technical and report writing and provides a sort of prescription for writing and organizing technical papers of all kinds. The second part is written in dictionary format and contains entries on grammar, style, and organization, as well as entries on topics such as common errors, resume writing, metric units, jargon, conference proceedings, figures, tables and slides. A comprehensive list of cross-references reveals related topics quickly and easily.

  17. TECHNICAL TRAINING SEMINAR

    CERN Multimedia

    Davide Vitè

    2002-01-01

    Wednesday 6 March TECHNICAL TRAINING SEMINAR from 9:30 to 16:45 - IT Amphitheatre - bldg. 31.3.004 Analog Devices DSP Day Thorsten Kistler (Application Engineer), Steffen Boerner (Product Specialist) / ANALOG DEVICES Munich Trying to meet your design challenges, Analog Devices compiles application information and offers chipsets, software, reference designs and mixed-signal, application specific DSPs, for a range of real-time signal processing applications. This seminar will present the latest 16bit fixed-point and 32bit floating-point DSPs (roadmaps; internal architectures, blocks, features benchmarks), with their software, development kits and emulators: Fixed-Point DSP-Family, ADSP-218x and ADSP-219x Blackfin DSP SHARC-Family, 2106x and 2116x TigerSHARC Industrial Contact: François Caloz, Sasco-Spoerle GmbH Language: English Free seminar, no registration Organiser: Davide Vitè / HR-TD / 75141 Davide.Vite@cern.ch Please read the full information on the Technical Training Seminars...

  18. Technical training: places available

    CERN Multimedia

    HR Department

    2007-01-01

    CERN Technical Training: Open Courses (April - June 2007) The following course sessions are currently scheduled in the framework of the CERN Technical Training Programme 2007:   AutoCAD 2006 - niveau 1 (course in French): 25.4.- 26.4.2007 & 2.5. - 3.5.2007 (4 days in 2 modules, 5 places available) AutoCAD 2006 - niveau 1 (course in French): 27.6.- 28.6.2007 & 3.7. - 4.7.2007 (4 days in 2 modules, 5 places available) AutoCAD Mechanical 2006 (course in French) 21.6.-22.6.2007 (2 days, 8 places available) * NEW COURSE* Automate de securite S7 (course in French) 14.5.-16.5.2007 (3 days, 4 places available) * NEW COURSE* Automate de securite S7 (course in French): 9.5.-11.5.2007 (3 days, 4 places available) JCOP - Joint PVSS-JCOP Frameswork (course in English): 21.5.-25.5.2007 (5 days, 12 places available) JCOP - Finite State Machines in the JCOP Frameswork (course in English): 12.6.-14.6.2007 (3 days, 12 places available) LabVIEW Basics 1 (in English): 2.-4.5.2007 (3 days, 7 places ...

  19. Technical Training: Places available

    CERN Multimedia

    Monique Duval

    2005-01-01

    The number of places available may vary. Please check our Web site to find out the current availability. Places are available on the following courses: Hands-on Introduction to Python Programming: 28 - 30.6.2005 (3 days) Introduction to ANSYS: 21 - 24.6.2005 (4 days) IT3T/3 - Working remotely with Windows XP: 28.6.2005 (IT Technical Training Tutorial, free of charge) IT3T/4 - Editing Websites with Frontpage 2003: 30.6.2005 (IT Technical Training Tutorial, free of charge) Utilisation des fichiers PDF avec ACROBAT 7.0 : 5.7.2005 (1 jour) FrontPage 2003 - niveau 1 : 6-7.7.2005 (2 jours) LabVIEW base 1 : 4 - 6.7.2005 (3 jours) LabVIEW Basics 2: 7 - 8.7.2005 (2 days) WORD 2003 (Short Course I) - HowTo... Work with repetitive tasks /AutoText, AutoFormat, AutoCorrect, Find/Replace) : 4.7.2005 (afternoon) WORD 2003 (Short Course II) - HowTo... Mail merge: 5.7.2005 (afternoon) WORD 2003 (Short Course III) - HowTo (4 mornings) EXCEL 2003 (Short Course I) - HowTo... Work ...

  20. Technical Training: Places available

    CERN Multimedia

    Monique Duval

    2005-01-01

    The number of places available may vary. Please check our Web site to find out the current availability. Places are available on the following courses: Hands-on Introduction to Python Programming: 28 - 30.6.2005 (3 days) Introduction to ANSYS: 28.6 - 1.7.2005 (4 days) IT3T/3 - Working remotely with Windows XP: 28.6.2005 (IT Technical Training Tutorial, free of charge) IT3T/4 - Editing Websites with Frontpage 2003: 30.6.2005 (IT Technical Training Tutorial, free of charge) LabVIEW base 1 : 4 - 6.7.2005 (3 jours) LabVIEW Basics 2: 7 - 8.7.2005 (2 days) Utilisation des fichiers PDF avec ACROBAT 7.0 : 5.7.2005 (1 jour) FrontPage 2003 - niveau 1 : 6-7.7.2005 (2 jours) WORD 2003 (Short Course I) - HowTo... Work with repetitive tasks /AutoText, AutoFormat, AutoCorrect, Find/Replace) : 4.7.2005 (afternoon) WORD 2003 (Short Course II) - HowTo... Mail merge: 5.7.2005 (afternoon) WORD 2003 (Short Course III) - HowTo... Work with long documents : 6.7.2005 (afternoon) ACCES...