WorldWideScience

Sample records for unit regulatory unit

  1. Regulatory audit to the Argentine teletherapy units

    International Nuclear Information System (INIS)

    Kay, J.M.

    1995-01-01

    As a consequence of an erroneous calibration of the ionization chamber dosimeter of a new licensed 6 Mev electron lineal accelerator that caused accidental overexposures in the first patients under treatment, the Regulatory Board decided to perform an audit to every teletherapy unit (accelerator and telegammatherapy units) in Argentina. The audit was carried out at the en of 1994 in 27 accelerators and 107 telegammatherapy units. The objectives of the audit were the control of the mechanical and optical aspects of the each accelerator and telegammatherapy unit and the control of the calibration of their radiation beams. The last action was undertaken to detect as soon as possible, any eventual accidental overexposure or underexposure of patients under treatment. The audit was conducted by the author and performed for a team of 22 inspectors who worked in groups of 2 to 3 people and completed the inspection of the teletherapy units of the whole country in 3 months. As a result of the audit, the Regulatory Board had in a short period a clear panorama of the performance of each teletherapy unit of the country and also confirmed that no accidental situation had happened. The audit revealed the necessity of imposing urgent regulatory requirements not related to the calibration of the radiation beam in 5% of the cases, as well as non-urgent requirements of different importance in approximately other 60% of the cases. (author)

  2. Development of regulatory requirements/guides for desalination unit coupled with nuclear plant

    International Nuclear Information System (INIS)

    Jo, Jong Chull; Yune, Young Gill; Kim, Woong Sik

    2005-10-01

    The basic design of System-integrated Modular Advanced Reactor (SMART), a small-to-medium sized integral type pressurized water reactor (PWR) with the capacity of 330MWth, has been developed in Korea. In order to demonstrate the safety and performance of the SMART design, 'Development Project of SMART-P (SMART-Pilot Plant)' has been being performed as one of the 'National Mid and Long-term Atomic Energy R and D Programs', which includes design, construction, and start-up operation of the SMART-P with the capacity of 65MWth, a 1/5 scaled-down design of the SMART. At the same time, a study on the development of regulatory requirements/guides for the desalination unit coupled with nuclear plant has been carried out by KINS in order to prepare for the forthcoming SMART-P licensing. The results of this study performed from August of 2002 to October of 2005 can be summarized as follows: (1) The general status of desalination technologies has been survey. (2) The design of the desalination plant coupled with the SMART-P has been investigated. (3) The regulatory requirements/guides relevant to a desalination unit coupled with a nuclear plant have been surveyed. (4) A direction on the development of domestic regulatory requirements/guides for a desalination unit has been established. (5) A draft of regulatory requirements/guides for a desalination unit has been developed. (6) Expert technical reviews have been performed for the draft regulatory requirements/guides for a desalination unit. The draft regulatory requirements/guides developed in this study will be finalized and can be applied directly to the licensing of the SMART-P and SMART. Furthermore, it will be also applied to the licensing of the desalination unit coupled with the nuclear plant

  3. Survey of regulatory agency review of generating unit performance

    International Nuclear Information System (INIS)

    Roach, E.M. Jr.; Tarletz, D.B.

    1985-01-01

    Regulatory agencies across the country are being called upon increasingly to monitor the management of electric utilities. Such activity, which once was relatively rare, is now common. Most frequently this oversight centers around the operating performance of generating units, both nuclear and fossil. There are, perhaps, several reasons for this increased interest in the efficient operation of generating units: increased fuel costs and fuel cost differentials, increased lead times and costs for construction of new generating units, and increased dependence on existing units because of construction programs being revised to meet decreased load growth. The monitoring of generating units has taken the form of after the fact evaluation of performance on a case-by-case basis and the implementation of productivity incentive programs. Performance standards are used in these contexts both to measure the adequacy of unit performance and to implement incentives in the form of rewards or penalties. The standard used may be a subjective test of prudent performance or some numerical index of plant performance, e.g., equivalent availability, capacity factor or heat rate. Some of the activity by regulators is reviewed in applying subjective and numerical standards and the considerations involved in applying such standards are discussed

  4. Conformance to Regulatory Guide 1.97, Arkansas Nuclear One, Unit No. 1

    International Nuclear Information System (INIS)

    Stoffel, J.W.

    1985-08-01

    This EG and G Idaho, Inc., report reviews the submittals for Regulatory Guide 1.97 for Unit No. 1 of Arkansas Nuclear One and identifies areas of nonconformance to the regulatory guide. Exceptions to Regulatory Guide 1.97 are evaluated and those areas where sufficient basis for acceptability is not provided are identified

  5. Continuing education requirements among State Occupational Therapy Regulatory Boards in the United States of America

    Directory of Open Access Journals (Sweden)

    Savannah R. Hall

    2016-10-01

    Full Text Available Purpose The purpose of this study is to compare and contrast the contents of each state’s occupational therapy (OT regulatory board requirements regarding licensees’ acquisition of continuing education units in the United States of America. Methods Data related to continuing education requirements from each OT regulatory board of all 50 states and the District of Columbia in the United States were reviewed and categorized by two reviewers. Analysis was conducted based on the categorization of the continuing education requirements and activities required, allowed, and not allowed/not mentioned for continuing education units. Results Findings revealed non-uniformity and inconsistency of continuing education requirements for licensure renewal between OT regulatory boards and was coupled with lack of specific criteria for various continuing education activities. Continuing education requirements were not tailored to meet the needs of individual licensee’s current and anticipated professional role and job responsibilities, with a negative bias towards presentation and publication allowed for continuing education units. Few boards mandated continuing education topics on ethics related to OT practice within each renewal cycle. Conclusion OT regulatory boards should move towards unifying the reporting format of continuing education requirements across all states to reduce ambiguity and to ensure licensees are equipped to provide ethical and competent practice. Efforts could be made to enact continuing education requirements specific to the primary role of a particular licensee. Finally, assigning the amount of continuing education credits to be awarded for different activities should be based on research evidence rather than arbitrary determination.

  6. Extra-regulatory impact tests and analyses of the structural evaluation test unit

    International Nuclear Information System (INIS)

    Ludwigsen, J.S.; Ammerman, D.J.

    1995-01-01

    The structural evaluation test unit is roughly equivalent to a 1/3 scale model of a high level waste rail cask. The test unit was designed to just meet the requirements of NRC Regulatory Guide 7.6 when subjected to a 9 m (30 ft) free drop resulting in an impact velocity of 13.4 m/s (30 mph) onto an unyielding target in the end-on orientation. The test unit was then subjected to impacts with higher velocities to determine the amount of built-in conservatism in this design approach. Test impacts of 13.4, 20.1 and 26.8 m/s (30, 45, and 60 mph) were performed. This paper will describe the design, testing, and comparison of measured strains and deformations to the equivalent analytical predictions

  7. Safety Experts Complete IAEA Nuclear Regulatory Review of the United States

    International Nuclear Information System (INIS)

    2010-01-01

    Full text: An international team of senior nuclear safety experts today completed a two-week International Atomic Energy Agency (IAEA) review of the governmental and regulatory framework for nuclear safety in the United States. The team identified good practices within the U.S. system and offered suggestions for ways the U.S. Nuclear Regulatory Commission (NRC) could improve. The IAEA has conveyed the team's main conclusions to the NRC, and a final report will be submitted to the NRC in about two months. At the request of the United States, the IAEA assembled a team of 19 international experts to conduct an Integrated Regulatory Review Service (IRRS) mission. This mission was a peer review based on the IAEA Safety Standards. It was not an inspection, nor an audit. The experts came from 14 different countries: Canada, China, the Czech Republic, Finland, France, Italy, Japan, Mexico, the Republic of Korea, Slovenia, Spain, Sweden, Switzerland, and the United Kingdom. Team leader Jukka Laaksonen of Finland said: ''We found a comprehensive, consistent, and mature regulatory system run by the NRC, which has a strong drive for continuous improvement.' The scope of the mission included the U.S. regulatory framework and the regulation of the nuclear plant operation. The mission was conducted from 18 to 29 October, mainly at NRC headquarters outside of Washington, D.C. To study U.S. regulatory activities, the mission conducted a series of interviews and discussions with NRC staff and other organizations to help assess the effectiveness of the regulatory system. In addition, the team observed regulatory activities at two operating nuclear power reactors and an emergency preparedness exercise. The IAEA's IRRS coordinator Gustavo Caruso said, ''This mission represents a milestone for the IRRS program because the U.S. regulatory system is the largest in the world and many nations look to it. The IRRS is a useful tool that allows host nations to gain guidance from experienced

  8. Preliminary regulatory audit calculation for Shinkori Units 3 and 4 LBLOCA

    Energy Technology Data Exchange (ETDEWEB)

    Woo, S. W.; Kim, B. S.; Kim, J. K. (and others)

    2006-12-15

    The objective of this study is to perform a preliminary evaluation for Shinkori Units 3 and 4 LBLOCA by applying KINS Realistic Evaluation Methodology (REM). The following results were obtained: (1) From the evaluation for Shinkori Units 3 and 4 LBLOCA, the peak cladding temperature was evaluated to meet the regulatory requirement and the feasibility of the KINS-REM was identified. (2) The input decks that were developed in the previous studies, were reviewed and the evaluation model of the fluidic device was developed and applied for the audit calculation. (3) The treating method for the uncertainty of the gap conductance was developed and applied for the audit calculation. (4) The pre- and post-processing programs were developed for this study. (5) For the more detailed assessments, the information for the gap conductance, etc. should be improved and the effects of coolant bypass during blowdown, steam binding and so on were not sufficiently evaluated. KINS-REM should be advanced to evaluate these effects properly. The KINS methodology that was used in this study, can be further applied for independent regulatory audit calculations related to the licensing application on LOCA best estimate calculation.

  9. Canadian and United States regulatory models compared: doses from atmospheric pathways

    International Nuclear Information System (INIS)

    Peterson, S-R.

    1997-01-01

    CANDU reactors sold offshore are licensed primarily to satisfy Canadian Regulations. For radioactive emissions during normal operation, the Canadian Standards Association's CAN/CSA-N288.1-M87 is used. This standard provides guidelines and methodologies for calculating a rate of radionuclide release that exposes a member of the public to the annual dose limit. To calculate doses from air concentrations, either CSA-N288.1 or the Regulatory Guide 1.109 of the United States Nuclear Regulatory Commission, which has already been used to license light-water reactors in these countries, may be used. When dose predictions from CSA-N288.1 are compared with those from the U.S. Regulatory Guides, the differences in projected doses raise questions about the predictions. This report explains differences between the two models for ingestion, inhalation, external and immersion doses

  10. Conformance to Regulatory Guide 1.97, River Bend Station, Unit No. 1 (Docket No. 50-458)

    International Nuclear Information System (INIS)

    Udy, A.C.

    1985-08-01

    This EG and G, Inc., report reviews the submittals for Regulatory Guide 1.97, Revision 3, for the River Bend Station, Unit No. 1. Any exception to Regulatory Guide 1.97 is evaluated and those areas where sufficient basis for acceptability is not provided are identified. 8 refs

  11. Conformance to Regulatory Guide 1.97, Beaver Valley Power Station, Unit No. 2 (Docket No. 50-412)

    International Nuclear Information System (INIS)

    Stoffel, J.W.; Udy, A.C.

    1985-11-01

    This EG and G Idaho, Inc., report reviews the submittals for Regulatory Guide 1.97 for Unit No. 2 of the Beaver Valley Power Station and identifies areas of nonconformance to the regulatory guide. Exceptions to Regulatory Guide 1.97 are evaluated and those areas where sufficient basis for acceptability is not provided are identified

  12. 77 FR 17569 - United States-Canada Regulatory Cooperation Council (RCC)-Transportation-Dangerous Goods Working...

    Science.gov (United States)

    2012-03-26

    ... identified in the Joint Action Plan, the Transportation--Dangerous Goods Working Group led by senior...)-- Transportation--Dangerous Goods Working Group AGENCY: Pipeline and Hazardous Materials Safety Administration...--Dangerous Goods Working Group, of the United States-Canada Regulatory Cooperation Council (RCC). Comments...

  13. National legislative and regulatory activities: Armenia, Brazil, Canada, France, Georgia, Greece, India, Ireland, Japan, Lithuania, Switzerland, Ukraine, United Arab Emirates, United States

    International Nuclear Information System (INIS)

    Anon.

    2012-01-01

    Armenia: Nuclear safety and radiological protection (Initiation of process relating to the life extension of nuclear power plant unit 2). Brazil: General legislation (Authorisation for the construction of nuclear submarines). Canada: Environmental protection (Changes to the federal environmental assessment law). France: Radioactive waste management (Changes to the National Plan for Management of Radioactive Materials and Waste). Georgia: Nuclear safety and radiological protection (New law on nuclear and radiation safety). Greece: Nuclear safety (Presidential decree on nuclear safety transposing European Council directive into national legislation); Emergency preparedness and response (Establishment of national plan for nuclear, radiological, biological and chemical threats). India: Licensing and regulatory infrastructure (Pending invitation for the IAEA's Integrated Regulatory Review Services to conduct a peer review); Liability and compensation (Committee on Subordinate Legislation Report on the Civil Liability for Nuclear Damage Rules, 2011). Ireland: Nuclear safety and radiological protection (Adoption of revised regulations regarding radiological protection). Japan: Nuclear Regulation Authority Act (Structure, Functions, New Nuclear Emergency Preparedness System). Lithuania: General legislation (New laws affecting Visaginas nuclear power plant project implementation); Licensing and regulatory infrastructure (Revised rules for issuing licenses and permits); Nuclear security (Revised physical protection requirements, New rules for the preparation of security plans); Radioactive waste management (Revised Rules of Procedure of Submission of Data on Activities Involving Radioactive Waste Disposal to the European Commission). Switzerland: General legislation (Draft energy strategy open for public comment until January 2013). Ukraine: Radioactive waste management (New law on development of a central repository); General legislation (Law providing for the location

  14. Regulatory approaches to, and practice of, PSA in Finland, France, Spain, Sweden, Switzerland, the United Kingdom, and the United States of America

    International Nuclear Information System (INIS)

    Baier, M.; Schaefer, A.

    2005-01-01

    Performing level-1 probabilistic safety analyses (PSA) is the established standard in most countries using nuclear power. In addition, level-2 PSA has become more and more widespread over the past few years. However, regulatory requirements and practice differ from country to country, especially with respect to level-2 analyses. In an effort to determine these differences more precisely, the ISaR Institute for Safety and Reliability, on behalf of VGB PowerTech Service GmbH, conducted a study of these seven countries: Finland, France, Spain, Sweden, Switzerland, the United Kingdom, and the United States. The study focused on level-2 PSA carried out by plant operators within the framework of periodic safety reviews. The findings of the study are based on extensive interviews of at least one expert each on the operators' and the authorities' side for each of the seven countries. Points taken into account in particular included the criteria imposed by regulators on PSA carried out by operators; the rank of PSA within the regulatory framework; the required versus the actual scopes of analysis; the objectives and uses of PSA; reviews of the analyses; the methods employed. (orig.)

  15. The public information aspects of nuclear regulatory inspection in the United States

    International Nuclear Information System (INIS)

    Volgenau, E.

    1977-01-01

    The public information aspects of the regulation of nuclear power present a unique set of problems. Not only must the regulators communicate often complex technical information to the public, they must also assure the public, the press and the legislative bodies of the adequacy of the regulatory process and the safety of power plant operations. The United States Nuclear Regulatory Commission (NRC), recognizing the importance of a continuing, open dialogue with the public, has placed particular emphasis on informing the public of its operations. NRC's experiences have been both good and bad. On balance, however, the NRC believes it is following the best course by conducting its operations openly and candidly. (author)

  16. Project management with regulatory constraints: Return to service of San Onofre Unit 1

    International Nuclear Information System (INIS)

    Hosmer, J.

    1986-01-01

    Station acceptance of the RTS work was completed in early November, 1984. The unit completed a successful integrated leak rate test, hot function test, and 200 hour warranty run in December, 1984 six weeks ahead of the CPUC mandate. Capital expenditures, although greater than the initial forecast, were two million dollars less than the 37.5 million dollar CPUC cap. The unit has run essentially trouble-free at current rated power until the current 1985 outage. Strategies and lessons learned that contributed to a successful RTS (e.g., all regulatory and economic constraints were met) included the use of numerous brainstorm sessions between SCE, Bechtel, and other consultants; innovative state of the art technical criterion (e.g., realistic versus overly conservative engineering); and budget and schedule contingencies consistent with the known and unknown risks

  17. Decree 328/003. Is approve the organizational structure reformulation project of the regulatory unit of Unit 006 Energy and water services of subsection 02 Presidency of the Republic

    International Nuclear Information System (INIS)

    2003-01-01

    This decree approve the organizational structure project of The regulatory energy and water services ( URSEA). This unit is responsible for monitoring the activities related to electricity, gas, drinking water, sanitation and oil, fuel and other hydrocarbon derivatives

  18. A regulatory view of containment integrity in the United Kingdom

    International Nuclear Information System (INIS)

    Bradford, P.M.; Patchett, C.M.

    1994-01-01

    This paper reviews the approach of HM Nuclear Installations Inspectorate (NII) to containment integrity in the United Kingdom (UK). NII is that part of the regulatory authority, the Health and Safety Executive (HSE), which administers the UK's nuclear site licensing system. A major part of the licensing process lies in the assessment of licensees' submissions for new and existing plant. The purpose of this paper is to: briefly review our revised Safety Assessment Principles, describe our assessment and inspection activities on the primary containment building of the Sizewell B PWR which is progressing to full power operation in 1994 and, to indicate our views on the possible directions for future research into containment design and performance. (author). 5 refs

  19. The enforcement program of the nuclear regulatory commission in the United States

    International Nuclear Information System (INIS)

    Thornburg, H.D.

    1977-01-01

    The enforcement program of the United States Nuclear Regulatory Commission consists of a clearly spelled out, evenly applied program of deterrents which escalate according to the nature of the offense and the past history of the licensee's noncompliances. Ninety-eight percent of all enforcement actions are normally handled by the five Regional offices. Only one percent of noncompliances have been classed as violations where significant safety consequences occurred. A strong and timely enforcement program is essential to insure that licensees fulfill their obligations to protect the public and the environment. (Auth.) [fr

  20. A regulatory view of containment integrity in the United Kingdom

    Energy Technology Data Exchange (ETDEWEB)

    Bradford, P M; Patchett, C M [Health and Safety Executive, Bootle (United Kingdom). Nuclear Installations Inspectorate

    1994-12-31

    This paper reviews the approach of HM Nuclear Installations Inspectorate (NII) to containment integrity in the United Kingdom (UK). NII is that part of the regulatory authority, the Health and Safety Executive (HSE), which administers the UK`s nuclear site licensing system. A major part of the licensing process lies in the assessment of licensees` submissions for new and existing plant. The purpose of this paper is to: briefly review our revised Safety Assessment Principles, describe our assessment and inspection activities on the primary containment building of the Sizewell B PWR which is progressing to full power operation in 1994 and, to indicate our views on the possible directions for future research into containment design and performance. (author). 5 refs.

  1. 10 CFR 20.1005 - Units of radioactivity.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Units of radioactivity. 20.1005 Section 20.1005 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION General Provisions § 20.1005 Units of radioactivity. For the purposes of this part, activity is expressed in the special unit of...

  2. Conformance to Regulatory Guide 1.97 Slurry Power Station, Unit Nos. 1 and 2 (Docket Nos. 50-280 and 50-281)

    International Nuclear Information System (INIS)

    Stoffel, J.W.

    1985-09-01

    This EG and G Idaho, Inc., report reviews the submittals for Regulatory Guide 1.97, Revision 3, for Unit Nos. 1 and 2 of the Surry Power Station and identifies areas of nonconformance to the regulatory guide. Exceptions to Regulatory Guide 1.97 are evaluated and those areas where sufficient basis for acceptability is not provided are identified

  3. Standardization of nuclear power plants in the United States: recent regulatory developments

    International Nuclear Information System (INIS)

    Cowan, B.Z.; Tourtellotte, J.R.

    1992-01-01

    On April 18, 1989, the United States (U.S.) Nuclear Regulatory Commission (NRC) amended the regulations governing the process for licensing nuclear power plants in the United States to provide for issuance of early site permits, standard design certifications and combined construction permits and operating licenses for nuclear power reactors. The new regulations are designed to achieve early resolution of licensing issues and facilitate standardization of nuclear power plants in the United States. The program for design standardization is central to efforts mounted by the U.S. government and industry to ensure that there will be a next generation of nuclear power facilities in the U.S. The most significant changes are provisions for certification of standard designs and for issuance prior to start of construction of combined licenses which incorporate a construction permit and an operating license with conditions. Such certifications and combined licenses must contain tests, inspections and analyses, and acceptance criteria, which are necessary and sufficient to provide reasonable assurance that the facility has been constructed and will operate in accordance with the combined license. A number of significant implementation issues have arisen. In addition a major court case brought by several anti-nuclear groups is pending, challenging NRC authority to issue combined licenses. It is the goal of the U.S. nuclear industry to have the first of the next generation of standardized nuclear power plants ordered, licensed, constructed and on-line by the year 2000. (author)

  4. 76 FR 40754 - Duke Energy Carolinas, LLC Catawba Nuclear Station, Units 1 and 2; McGuire Nuclear Station, Units...

    Science.gov (United States)

    2011-07-11

    ... NUCLEAR REGULATORY COMMISSION [NRC-2011-0100; Docket Nos. 50-413 and 50-414; Docket Nos. 50-369 and 50-370; Docket Nos. 50-269, 50-270, And 50-287] Duke Energy Carolinas, LLC Catawba Nuclear Station, Units 1 and 2; McGuire Nuclear Station, Units 1 and 2; Oconee Nuclear Station, Units 1, 2, and 3; Notice...

  5. Exploring the impact of permitting and local regulatory processes on residential solar prices in the United States

    International Nuclear Information System (INIS)

    Burkhardt, Jesse; Wiser, Ryan; Darghouth, Naïm; Dong, C.G.; Huneycutt, Joshua

    2015-01-01

    This article statistically isolates the impacts of city-level permitting and other local regulatory processes on residential PV prices in the United States. We combine data from two “scoring” mechanisms that independently capture local regulatory process efficiency with the largest dataset of installed PV prices in the United States. We find that variations in local permitting procedures can lead to differences in average residential PV prices of approximately $0.18/W between the jurisdictions with the least-favorable and most-favorable permitting procedures. Between jurisdictions with scores across the middle 90% of the range (i.e., 5th percentile to 95th percentile), the difference is $0.14/W, equivalent to a $700 (2.2%) difference in system costs for a typical 5-kW residential PV installation. When considering variations not only in permitting practices, but also in other local regulatory procedures, price differences grow to $0.64–$0.93/W between the least-favorable and most-favorable jurisdictions. Between jurisdictions with scores across the middle 90% of the range, the difference is equivalent to a price impact of at least $2500 (8%) for a typical 5-kW residential PV installation. These results highlight the magnitude of cost reduction that might be expected from streamlining local regulatory regimes. - Highlights: • We show local regulatory processes meaningfully affect U.S. residential PV prices. • We use regression analysis and two mechanisms for “scoring” regulatory efficiency. • Local permitting procedure variations can produce PV price differences of $0.18/W. • Broader regulatory variations can produce PV price differences of $0.64–$0.93/W. • The results suggest the cost-reduction potential of streamlining local regulations

  6. An overview of the corrective action management unit and temporary unit regulations

    International Nuclear Information System (INIS)

    Green, D.R.; Corathers, L.; Coalgate, J.

    1995-01-01

    In February 1993, the US Environmental Protection Agency (EPA) promulgated the corrective action management unit (CAMU) and temporary unit (TU) regulations as 40 CFR Part 264, Subpart S. These regulations are intended to foster the selection of protective and cost-effective remedies for the restoration of sites contaminated by hazardous substances, hazardous wastes, and hazardous waste constituents by removing certain regulatory impediments to implementing those remedies, most notably those of the land disposal restrictions (LDRs). This paper provides a brief overview of the CAMU and TU regulations

  7. Regulatory approaches in the United States of America for safe management and disposal of long-lived radionuclides

    International Nuclear Information System (INIS)

    Greeves, J.T.; Bell, M.J.; Nelson, R.A.

    1998-01-01

    Regulation of the safe management and disposal of commercial, man-made, long-lived radioactive wastes in the United States is the responsibility of the US Nuclear Regulatory Commission (NRC). In some instances, state regulatory authorities have entered into agreements with the NRC to exercise regulatory authority over management and disposal of low-level radioactive wastes and uranium mill tailings within their borders. The legal and regulatory framework employed to achieve safe management and disposal of long-lived radioactive wastes in the US regulatory system is quite detailed, and in many cases the requirements are considerably prescriptive. The NRC has undertaken an initiative to move in the direction of adopting risk-informed, performance-based and risk-informed, less-prescriptive regulations. The current status and future direction of the legal and regulatory framework for management and disposal of commercial long-lived radioactive waste in the US is described. (author)

  8. Regulatory alerts for dietary supplements in Canada and the United States, 2005-13.

    Science.gov (United States)

    Abe, Andrew M; Hein, Darren J; Gregory, Philip J

    2015-06-01

    Dietary supplement regulatory alerts published by the Food and Drug Administration (FDA) and Health Canada were evaluated and characterized. FDA MedWatch and Health Canada websites were reviewed to identify regulatory alerts regarding dietary supplements from January 1, 2005, through December 31, 2013. Alerts were analyzed to identify product characteristics that may be predictive of product quality issues and potential patient harm. A total of 1560 dietary supplement-related regulatory alerts were identified. Of those, 1287 (83%) were identified through Health Canada, and 273 (18%) were identified through FDA MedWatch. The country of origin of dietary supplements associated with regulatory alerts was not provided in most regulatory alerts; however, when their origin was provided, the United States was the most common. Dietary supplements intended for sexual enhancement were the subject of 33% of all regulatory alerts identified. Products purchased online were the most likely to be associated with a regulatory alert. Dietary supplements intended for sexual enhancement, weight loss, and bodybuilding or athletic performance appeared to pose the greatest risk for patient harm due to product contamination with a pharmaceutical such as a phosphodiesterase-5 inhibitor or sibutramine. Analysis of Canadian and U.S. regulatory alerts concerning dietary supplements revealed that more than 80% of the composite alerts were issued by Health Canada. The most common intended uses of supplements for which alerts were issued were sexual enhancement, weight loss, and bodybuilding or athletic performance. The most common reason for alerts was the presence of a pharmaceutical contaminant. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  9. Conformance to Regulatory Guide 1.97, Perry Nuclear Power Plant, Unit Nos. 1 and 2 (Docket Nos. 50-440 and 50-441)

    International Nuclear Information System (INIS)

    Udy, A.C.

    1985-03-01

    This EG and G Idaho, Inc., report provides a review of the submittals for Regulatory Guide 1.97, Revision 2, for the Perry Nuclear Power Plant, Unit Nos. 1 and 2. Any exception to the guidelines of Regulatory Guide 1.97 are evaluated

  10. Scientific and Regulatory Perspectives in Herbal and Dietary Supplement Associated Hepatotoxicity in the United States

    Directory of Open Access Journals (Sweden)

    Mark I. Avigan

    2016-03-01

    Full Text Available In the United States (US, the risk of hepatotoxicity linked to the widespread use of certain herbal products has gained increased attention among regulatory scientists. Based on current US law, all dietary supplements sold domestically, including botanical supplements, are regulated by the Food and Drug Administration (FDA as a special category of foods. Under this designation, regulatory scientists do not routinely evaluate the efficacy of these products prior to their marketing, despite the content variability and phytochemical complexity that often characterizes them. Nonetheless, there has been notable progress in the development of advanced scientific methods to qualitatively and quantitatively measure ingredients and screen for contaminants and adulterants in botanical products when hepatotoxicity is recognized.

  11. Conformance to Regulatory Guide 1.97, Joseph M. Farley Nuclear Plant, Unit Nos. 1 and 2 (Docket No. 50-348 and 50-364)

    International Nuclear Information System (INIS)

    Stoffel, J.W.

    1985-05-01

    This EG and G Idaho, Inc., report reviews the submittals for Regulatory Guide 1.97 for Unit Nos. 1 and 2 of the Joseph M. Farley Nuclear Plant and identifies areas of nonconformance to the regulatory guide. Exceptions to Regulatory Guide 1.97 are evaluated and those areas where sufficient basis for acceptability is not provided are identified

  12. 76 FR 82323 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units

    Science.gov (United States)

    2011-12-30

    ... Filtration and Adsorption Units AGENCY: Nuclear Regulatory Commission. ACTION: Draft regulatory guide... for Air Filtration and Adsorption Units of Postaccident Engineered-Safety-Feature Atmosphere Cleanup... testing of air filtration and iodine adsorption units of engineered-safety-feature (ESF) atmosphere...

  13. A regulatory view of the seismic assessment of existing nuclear structures in the United Kingdom

    International Nuclear Information System (INIS)

    Inkester, J.E.

    2001-01-01

    The paper describes the background to the seismic assessment of existing nuclear structures in the United Kingdom. Nuclear installations in this country were not designed specifically to resist earthquakes until the nineteen-seventies, although older plants were robustly constructed. The seismic capability of these older installations is now being evaluated as part of the periodic safety reviews which nuclear licensees are required to carry out. The regulatory requirements which set the framework for these studies are explained. The licensees' processes of hazard appraisal and examination of the response of the structure are briefly summarized. Regulatory views on some of the criteria used to judge the adequacy of safety are discussed. Finally the paper provides some comments on future initiatives and possible areas of development. (author)

  14. Conformance to Regulatory Guide 1.97, Shearon Harris Nuclear Power Plant, Unit Nos. 1 and 2 (Docket Nos. 50-400 and 50-401)

    International Nuclear Information System (INIS)

    Stoffel, J.W.

    1985-09-01

    This EG and G Idaho, Inc. report reviews the submittals for Regulatory Guide 1.97, Revision 3, for Unit Nos. 1 and 2 of the Shearon Harris Nuclear Power Plant and identifies areas of nonconformance to the regulatory guide. Exceptions to Regulatory Guide 1.97 are evaluated and those areas where sufficient basis for acceptability is not provided are identified. 7 refs

  15. United States nuclear regulatory commission program for inspection of decommissioning nuclear power plants

    International Nuclear Information System (INIS)

    Harris, P.W.

    2001-01-01

    The United States Nuclear Regulatory Commission (USNRC or Commission) has been inspecting decommissioning commercial nuclear power plants in the United States (U.S.) since the first such facility permanently shutdown in September 1967. Decommissioning inspections have principally focused on the safe storage and maintenance of spent reactor fuel; occupational radiation exposure; environmental radiological releases; the dismantlement and decontamination of structures, systems, and components identified to contain or potentially contain licensed radioactive material; and the performance of final radiological survey of the site and remaining structures to support termination of the USNRC-issued operating license. Over the last 5 years, USNRC inspection effort in these areas has been assessed and found to provide reasonable confidence that decommissioning can be conducted safely and in accordance with Commission rules and regulations. Recently, the staff has achieved a better understanding of the risks associated with particular decommissioning accidents 1 and plans to apply these insights to amendments proposed to enhance decommissioning rules and regulations. The probabilities, scenarios, and conclusions resulting from this effort are being assessed as to their applicability to the inspection of decommissioning commercial power reactors. (author)

  16. United States nuclear regulatory commission program for inspection of decommissioning nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Harris, P.W. [U.S. Nuclear Regulatory Commission, Washington, DC (United States)

    2001-07-01

    The United States Nuclear Regulatory Commission (USNRC or Commission) has been inspecting decommissioning commercial nuclear power plants in the United States (U.S.) since the first such facility permanently shutdown in September 1967. Decommissioning inspections have principally focused on the safe storage and maintenance of spent reactor fuel; occupational radiation exposure; environmental radiological releases; the dismantlement and decontamination of structures, systems, and components identified to contain or potentially contain licensed radioactive material; and the performance of final radiological survey of the site and remaining structures to support termination of the USNRC-issued operating license. Over the last 5 years, USNRC inspection effort in these areas has been assessed and found to provide reasonable confidence that decommissioning can be conducted safely and in accordance with Commission rules and regulations. Recently, the staff has achieved a better understanding of the risks associated with particular decommissioning accidents 1 and plans to apply these insights to amendments proposed to enhance decommissioning rules and regulations. The probabilities, scenarios, and conclusions resulting from this effort are being assessed as to their applicability to the inspection of decommissioning commercial power reactors. (author)

  17. Nuclear Legislation in OECD and NEA Countries. Regulatory and Institutional Framework for Nuclear Activities - United Kingdom

    International Nuclear Information System (INIS)

    2003-01-01

    This country profile provide comprehensive information on the regulatory and Institutional Framework governing nuclear activities as well as a detailed review of a full range of nuclear law topics, including: mining regime; radioactive substances; nuclear installations; trade in nuclear materials and equipment; radiation protection; radioactive waste management; non-proliferation and physical protection; transport; and nuclear third party liability. The profile is complemented by reproductions of the primary legislation regulating nuclear activities in the country. Content: I. General Regulatory Regime: 1. Introduction; 2. Mining Regime; 3. Radioactive Substances; 4. Nuclear Installations (Licensing and inspection, including nuclear safety; Protection of the environment against radiation effects; Emergency response); 5. Trade in Nuclear Materials and Equipment; 6. Radiation Protection; 7. Radioactive Waste Management; 8. Non-Proliferation and Physical Protection; 9. Transport; 10. Nuclear Third Party Liability; II. Institutional Framework: 1. Regulatory and Supervisory Authorities (Department of Trade and Industry - DTI; Secretary of State for Environment, Food and Rural Affairs and the Secretary of State for Health; Secretary of State for Transport; Secretary of State for Education); 2. Advisory Bodies (Medical Research Council - MRC; Nuclear Safety Advisory Committee; Radioactive Waste Management Advisory Committee); 3. Public and Semi-Public Agencies (United Kingdom Atomic Energy Authority - UKAEA; Health and Safety Commission and Executive - HSC/HSE; National Radiological Protection Board - NRPB; Environment Agencies; British Nuclear Fuels plc. - BNFL; Amersham International plc.; The National Nuclear Corporation Ltd. - NNC; United Kingdom Nirex Ltd.; Magnox Electric plc.; British Energy Generation Ltd.; Scottish Electricity Generator Companies; British Energy Generation Ltd.; Regional Electricity Companies in England and Wales)

  18. Establishing Policy Foundations and Regulatory Systems to Enhance Nursing Practice in the United Arab Emirates.

    Science.gov (United States)

    Brownie, Sharon M; Hunter, Lyndal H; Aqtash, Salah; Day, Gary E

    2015-01-01

    In 2009, the United Arab Emirates (UAE) established a Nursing and Midwifery Council with a mandate to develop standards for the registration and regulation of nursing and midwifery and to strengthen the nursing and midwifery workforce. Priorities included workforce Emiratization and the development of regulatory standards to support advanced and speciality nursing practice and new models of care-particularly for the management of noncommunicable diseases. This article provides background, context for, and best practice inputs to the effort to provide one unified framework of nursing regulation and licensure across the whole of the UAE. This article is intended for nurse leaders, policy makers, and regulators who are reviewing or developing nursing regulatory processes and advancing nursing workforce capacity building activities; and nurse educators and nurses wishing to work in the UAE. © The Author(s) 2015.

  19. Regulatory responses to over-the-counter codeine analgesic misuse in Australia, New Zealand and the United Kingdom.

    Science.gov (United States)

    Tobin, Claire L; Dobbin, Malcolm; McAvoy, Brian

    2013-10-01

    Analysis of the policy response by Australia's National Drugs and Poisons Schedule Committee (NDPSC) and comparison with recommendations by expert advisory committees in New Zealand and the United Kingdom. Analysis of public policy documents of relevant regulatory authorities was conducted. Data were extracted regarding changes to over-the-counter (OTC) codeine analgesic scheduling, indications, maximum unit dose, maximum daily dose, maximum pack size, warning labels, consumer medicine information and advertising. Where available, public submissions and other issues considered by the committees and rationale for their recommendations were recorded and thematically analysed. Expert advisory committees in Australia, NZ and the UK defined the policy problem of OTC codeine misuse and harm as small relative to total use and responded by restricting availability. Pharmacist supervision was required at the point-of-sale and pack sizes were reduced to short-term use. Comparison with recommendations by expert advisory committees in NZ and the UK suggests the NDPSC's actions in response to OTC codeine misuse were appropriate given the available evidence of misuse and harm, but highlights opportunities to utilise additional regulatory levers. Framing policy problems as matters of public health in the context of limited evidence may support decision makers to implement cautionary incremental policy change. © 2013 The Authors. ANZJPH © 2013 Public Health Association of Australia.

  20. Spent fuel pool cooling system upgrade for Kori Unit 1

    International Nuclear Information System (INIS)

    Sun Park, Jong; In Shin, Kyung

    2014-01-01

    Following Fukushima nuclear power plant accident, the needs for reliable performance of its own safety functions of Spent Fuel Pool Cooling System (SFPCS) has risen significantly to maintain the plant in a safe condition. Regulatory Guide 1.13 of United States Nuclear Regulatory Commission (USNRC) requires the SFPCS shall be designed safety related as Quality Group C and Seismic Category 1. However, the existing Spent Fuel Pool (SFP) of KORI Unit 1 was not designed as a safety system. In order to comply with the above licensing requirement for the extended operational life of KORI Unit 1, it has been decided to add a safety related Seismic Category 1 Makeup System to KORI Unit 1 and the existing SFPCS to be modified in dedicated channels with safety related equipment to enhance system's reliability as a means of providing diversity. This paper focuses on describing the relevant design requirements, applications, and supplemental facilities to the SFPCS of KORI Unit 1. (authors)

  1. 78 FR 49553 - Three Mile Island, Unit 2; Post Shutdown Decommissioning Activities Report

    Science.gov (United States)

    2013-08-14

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-320; NRC-2013-0183] Three Mile Island, Unit 2; Post Shutdown Decommissioning Activities Report AGENCY: Nuclear Regulatory Commission. ACTION: Notice of receipt... Shutdown Decommissioning Activity Report (PSDAR) for Three Mile Island, Unit 2 (TMI-2). The PSDAR provides...

  2. Conformance to Regulatory Guide 1.97 Browns Ferry Nuclear Plant, Unit Nos. 1, 2 and 3 (Docket Nos. 50-259, 50-260, and 50-296)

    International Nuclear Information System (INIS)

    Udy, A.C.

    1985-07-01

    This EG and G Idaho, Inc., report reviews the submittals for Regulatory Guide 1.97, Revision 3, for Unit Nos. 1, 2 and 3 of the Browns Ferry Nuclear Plant and identifies areas of nonconformance to the regulatory guide. Exceptions to Regulatory Guide 1.97 are evaluated and those areas where sufficient basis for acceptability is not provided are identified

  3. Feasibility for the medium efficiency filter as a postfilter in the air cleaning unit

    International Nuclear Information System (INIS)

    Lim, H. S.; Jung, D. Y.; Byun, S. C.; Kim, S. H.

    2002-01-01

    The Air Cleaning Unit (ACU) is provided in a nuclear facility to filter the radioactive materials in gaseous effluents released from the facility during normal operation and during a postulated accident. The Air Cleaning Unit (ACU) consists of pre-HEPA filters, charcoal adsorber, post HEPA filters, fans, etc. The charcoal filters keep on-site dose and off-site effluents ALARA, consistent with regulatory requirements. The function of HEPA filter downstream of charcoal(carbon) adsorber in ACU is to catch potential radioactive carbon dust and to be a backup in the event of failure of upstream HEPA. Previous Regulatory Guide use only post HEPA filter of charcoal adsorber downstream but the Regulatory Guide of current revisions allows use of 95% dust spot efficiency filters in lieu of HEPA at the downstream of the carbon adsorber. In this paper is described that the background information of filters, Current Regulatory Guide of revised by the United States Nuclear Regulatory Commission and the feasibility for the medium efficiency filter as a carbon adsorber post filter in the Air Cleaning Unit

  4. Regulatory Lessons for Internet Traffic Management from Japan, the European Union, and the United States: Toward Equity, Neutrality and Transparency

    Directory of Open Access Journals (Sweden)

    John Harris Stevenson

    2010-01-01

    Full Text Available As network neutrality has been one of the most contentious Internet public policy issues of the past decade, this article provides a comparative overview of events, policies, and legislation surrounding Internet traffic management practises (ITMPs (e.g., network neutrality in Japan, the European Union, the United States, and Canada. Using the frame provided by Richard Rose of “hybrid lessons”to create a policy synthesis, the paper details the telecom policy environment, Internet Service provider competition, legislative jurisdiction, remedies for ITMPs, consumer transparency, and adherence to privacy protection in each country. The analysis focuses on Canada’s first significant regulatory effort to address network neutrality, which came during the Canadian Radio-television and Telecommunications Commission 2009 process on Internet traffic management. This paper presents a brief overview of the Canadian regulatory environment and the specific questions which were the subject of the CRTC review. Employing Richard Rose’s methods for comparative public policy analysis, we offer a number of regulatory “lessons” from Japan, the European Union, and the United States based on their experiences with traffic management issues. Applying these lessons to the Canadian context, we make several specific policy recommendations, among them that competition be encouraged within the Internet service provider space, that network management practises be reasonable and limited, and that ISPs provide full disclosure of network management policies and practises.

  5. Nuclear power in the United States

    International Nuclear Information System (INIS)

    Johnston, J.B.

    1985-01-01

    All over the world except in the United States, nuclear energy is a low cost, secure, environmentally acceptable form of energy. In the United States, civilian nuclear power is dead. 112 nuclear power plants have been abandoned or cancelled in the last decade, and there has been no new order for nuclear plants since 1978. It will be fortunate to have 125 operating nuclear plants in the United States in the year 2000. There are almost 90 completed nuclear power plants and about 45 under construction in the United States, but several of those under construction will eventually be abandoned. About 20 % of the electricity in the United States will be generated by nuclear plants in 2000 as compared with 13 % supplied in the last year. Under the present regulatory and institutional arrangement, American electric utilities would not consider to order a new nuclear power plant. Post-TMI nuclear plants became very expensive, and there is also ideological opposition to nuclear power. Coal-firing plants are also in the similar situation. The uncertainty about electric power demand, the cost of money, the inflation of construction cost and regulation caused the situation. (Kako, I.)

  6. Green electricity policies in the United States: case study

    International Nuclear Information System (INIS)

    Menz, Fredric C.

    2005-01-01

    While there has been interest in promoting the use of renewable energy in electricity production for a number of years in the United States, the market share of non-hydro renewable energy sources in electricity production has remained at about 2 percent over the past decade. The paper reviews the principal energy resources used for electricity production, considers the changing regulatory environment for the electricity industry, and describes government policies that have been used to promote green electricity in the United States, with an emphasis on measures adopted by state governments. Factors influencing the development of green power markets are also discussed, including underlying economic issues, public policy measures, the regulatory environment, external costs, and subsidies. Without significant increases in fossil fuel prices, much more stringent environmental regulations, or significant changes in electricity customer preferences, green electricity markets are likely to develop slowly in the United States

  7. Regulatory application of seismic experience data for nuclear power plants in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Pei-Ying [Nuclear Regulatory Commission, Washington, DC (United States)

    1997-03-01

    On the basis of its review and evaluation (Reference 3) of the SQUG GIP (Reference 2) and on the basis of the differences between current seismic qualification requirements and the criteria and procedures provided in the GIP, the NRC staff does not consider the USI A-46 methodology given in the GIP to be a `seismic qualification` procedure. Rather, the staff considers the GIP methodology to be a seismic adequacy verification procedure, which was developed on the basis of generic equipment earthquake experience data, supplemented by generic equipment test data. The implementation of the GIP approach for USI A-46 plants provides safety enhancement, in certain aspects, beyond the original licensing bases. Therefore, the GIP methodology is an acceptable evaluation method, for USI A-46 plants only, to verify the seismic adequacy of the safe-shutdown equipment installed in the NPPs in the United States. With the new development in the experience-based approach for seismic qualification of equipment currently underway in the U.S. nuclear industry, there is a potential for future regulatory application of an experience-based approach as a seismic qualification method for certain selected equipment installed in NPPs in the United States. However, industry`s use of the experience-based approach will be dependent on the submittal and staff approval of this approach. (J.P.N.)

  8. Medical revalidation as professional regulatory reform: Challenging the power of enforceable trust in the United Kingdom.

    Science.gov (United States)

    Spendlove, Zoey

    2018-05-01

    For more than two decades, international healthcare crises and ensuing political debates have led to increasing professional governance and regulatory policy reform. Governance and policy reforms, commonly representing a shift from embodied trust in professionals to state enforceable trust, have challenged professional power and self-regulatory privileges. However, controversy remains as to whether such policies do actually shift the balance of power and what the resulting effects of policy introduction would be. This paper explores the roll-out and operationalisation of revalidation as medical regulatory reform within a United Kingdom National Health Service hospital from 2012 to 2013, and its impact upon professional power. Revalidation policy was subject to the existing governance and management structures of the organisation, resulting in the formal policy process being shaped at the local level. This paper explores how the disorganised nature of the organisation hindered rather than facilitated robust processes of professional governance and regulation, fostering formalistic rather than genuine professional engagement with the policy process. Formalistic engagement seemingly assisted the medical profession in retaining self-regulatory privileges whilst maintaining professional power over the policy process. The paper concludes by challenging the concept of state enforceable trust and the theorisation that professional groups are effectively regulated and controlled by means of national and organisational objectives, such as revalidation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Preservation and Implementation of Decommissioning Lessons Learned in the United States Nuclear Regulatory Commission

    International Nuclear Information System (INIS)

    Rodriguez, Rafael L.

    2008-01-01

    Over the past several years, the United States Nuclear Regulatory Commission (NRC) has actively worked to capture and preserve lessons learned from the decommissioning of nuclear facilities. More recently, NRC has involved industry groups, the Organization of Agreement States (OAS), and the Department of Energy (DOE) in the effort to develop approaches to capture, preserve and disseminate decommissioning lessons learned. This paper discusses the accomplishments of the working group, some lessons learned by the NRC in the recent past, and how NRC will incorporate these lessons learned into its regulatory framework. This should help ensure that the design and operation of current and future nuclear facilities will result in less environmental impact and more efficient decommissioning. In summary, the NRC will continue capturing today's experience in decommissioning so that future facilities can take advantage of lessons learned from today's decommissioning projects. NRC, both individually and collectively with industry groups, OAS, and DOE, is aggressively working on the preservation and implementation of decommissioning lessons learned. The joint effort has helped to ensure the lessons from the whole spectrum of decommissioning facilities (i.e., reactor, fuel cycle, and material facilities) are better understood, thus maximizing the amount of knowledge and best practices obtained from decommissioning activities. Anticipated regulatory activities at the NRC will make sure that the knowledge gained from today's decommissioning projects is preserved and implemented to benefit the nuclear facilities that will decommission in the future

  10. Study of the impacts of regulations affecting the acceptance of Integrated Community Energy Systems: public utility, energy facility siting and municipal franchising regulatory programs in the United States. Preliminary background report

    Energy Technology Data Exchange (ETDEWEB)

    Feurer, D.A.; Weaver, C.L.; Gallagher, K.C.; Hejna, D.; Rielley, K.J.

    1980-01-01

    This report is one of a series of preliminary reports describing the laws and regulatory programs of the United States and each of the 50 states affecting the siting and operation of energy generating facilities likely to be used in Integrated Community Energy Systems (ICES). Public utility regulatory statutes, energy facility siting programs, and municipal franchising authority are examined to identify how they may impact on the ability of an organization, whether or not it be a regulated utility, to construct and operate an ICES. This report describes laws and regulatory programs in the United States. Subsequent reports will (1) describe public utility rate regulatory procedures and practices as they might affect an ICES, (2) analyze each of the aforementioned regulatory programs to identify impediments to the development of ICES, and (3) recommend potential changes in legislation and regulatory practices and procedures to overcome such impediments.

  11. Cernavoda - Unit 2. A strategic project for Romania

    International Nuclear Information System (INIS)

    Saroudis, J.I.; Chirica, T.; Villabruna, G.

    1999-01-01

    The paper presents some key aspects of the Romanian nuclear program, focusing on Cernavoda NPP Unit No. 2 and the partnership with Atomic Energy of Canada Ltd. (AECL) and ANSALDO Italy for completion of this project. A brief historical presentation of the Romanian nuclear program is included. The success of Cernavoda NPP Unit 1 represents an important element in finalizing Unit 2 in an advanced state of equipment installation and more than 40 % complete. Also, the national infrastructure, including the legal framework and new Electricity Law represents a positive element for Project completion. The Romanian Nuclear Regulatory Body represents the guarantee for the safe operation of CANDU reactors in Romania.(author)

  12. Specific problems and practical experience of regulatory inspection during commissioning in the United Kingdom

    International Nuclear Information System (INIS)

    Lewis, G.

    1977-01-01

    The commissioning of nine Magnox and two Advanced Gas-cooled Reactor Nuclear Power Plants in the United Kingdom during the last sixteen years under the regulatory control of the Nuclear Installations Inspectorate of the Health and Safety Executive has been based on a Stage Approval Philosophy starting with proof-testing of the primary gas circuit and concluding with tests on the reactor at full power. The practical experience gained during this period has enabled the Nuclear Installations Inspectorate to rationalise the procedures and test requirements without comporomising safety standards. The Operating Rules and Maintenance Schedules are approved for commissioning and during this period are reviewed for their adequacy for future power operation of the plant. The organisation, documentation, test procedures and the commissioning programme used for the Advanced Gas-cooled Reactors are briefly explained. (author)

  13. A regulatory perspective of the role of construction in revitalizing the United States nuclear industry

    International Nuclear Information System (INIS)

    Stello, V. Jr.

    1983-01-01

    Technical and managerial experience in nuclear power plant construction is presented from the perspective of the United States Nuclear Regulatory Commission (NRC). In the context of actions that would contribute to revitalizing the nuclear industry in the United States of America, greater effectiveness of utility management during construction is proposed. The reasons why management effectiveness is so important are developed beginning with summaries of defects that were built into several US plants under construction. The root causes of these significant defects were management failures. In terms of benefits, effective management is important because of its effects on nuclear safety, project construction costs, and future reliability of the plant after commissioning. Actions that would enhance good management include emphasizing the inseparable nature of production and quality, that quality cannot be inspected into a plant, and that a strong construction management staff and exchanges of experience and information are essential. Techniques that have been used successfully in construction management are discussed. NRC and industry initiatives are in progress to improve management responsibility and learning from experience. Projects include Owner's Certification, assessments of licensee performance, fostering good practices across the industry, and improving the NRC inspection programme. Revitalization will not be easy, but it is achievable. (author)

  14. A regulatory perspective on the abuse potential evaluation of novel stimulant drugs in the United States.

    Science.gov (United States)

    Calderon, Silvia N; Klein, Michael

    2014-12-01

    In the United States of America (USA), the abuse potential assessment of a drug is performed as part of the safety evaluation of a drug under development, and to evaluate if the drug needs to be subject to controls that would minimize the abuse of the drug once on the market. The assessment of the abuse potential of new drugs consists of a scientific and medical evaluation of all data related to abuse of the drug. This paper describes the regulatory framework for evaluating the abuse potential of new drugs, in general, including novel stimulants. The role of the United States Food and Drug Administration (FDA) in the evaluation of the abuse potential of drugs, and its role in drug control are also discussed. A definition of abuse potential, an overview of the currently accepted approaches to evaluating the abuse potential of a drug, as well as a description of the criteria that applies when recommending a specific level of control (i.e., a Schedule) for a drug under the Controlled Substances Act (CSA). This article is part of the Special Issue entitled 'CNS Stimulants'. Published by Elsevier Ltd.

  15. Safety R and D Needs in Multi-Unit PSA from a Regulatory Viewpoint

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Gyunyoung; Yoon, Ji Woong [Kyung Hee University, Yongin (Korea, Republic of); Kim, Man Cheol [Chung-Ang University, Seoul (Korea, Republic of)

    2016-10-15

    The Nuclear Safety and Security Commission (NSSC) NSSC’s recent approval of the construction permits and operation licenses of Shin Kori units 3 to 6 has brought attention to the multi-unit probabilistic safety assessment (PSA). The disaster in Fukushima revealed the risks associated with the use of spent fuel pools (SFPs), and the linear (or non-linear) consequences of radiation leaks from multi-units in particular, has raised concerns. The number of nuclear power plants (NPPs) in operation will increase to ten at the Kori and Shin Kori sites when the construction of Units 5 and 6 is complete - the highest concentration of power reactors in one region in world history. Nuclear disasters do not happen frequently, but when one does happen, its cascading effects can inflict massive human and environmental loss. Proper safety measures are needed as more nuclear installations are put in place. Nuclear regulators are forced to promptly produce a sufficient degree of realistic and objective risk assessment results to meet the rapidly-increasing demand for multi-unit PSA, while striving to achieve matching levels of technological development. The issues with the technological aspects of PSA would still be inherent even after a few years of research, and ensuring the safety of multi-units would still prove challenging. Experts are however relieved that the general public is now much more familiar with the concept of PSA than in the past, which indicates a rise in the degree of public understanding of technology. More studies should be done on multi-unit regulation and safety so as to steer the government in the proper direction for enacting policies aimed to ensure the health of local residents. In conclusion, the technical problems associated with multi-unit PSA that were not mentioned in this paper are essentially similar to their single-unit counterparts, therefore, reinforcing the base infrastructure of PSAs in general will work towards resolving such technical

  16. Review of nuclear regulatory activities associated with safety culture and the management of safety in the United Kingdom

    International Nuclear Information System (INIS)

    Woodhouse, P.A.

    1995-01-01

    This paper describes some of the key regulatory activities which have taken place in the United Kingdom in recent years in the areas of safety culture and management of safety. It explains how the UK's nuclear licensing regime, regulated and enforced by the Nuclear Installations Inspectorate, (NII), provides the framework for a viable safety management system and identifies a management of safety model which a NII Task Force has developed. It finally identifies further work which is being undertaken by the NII. (author). 4 refs, 2 figs

  17. The Issue of Unit Constraints and the Non-Confiscatory Electricity Market

    DEFF Research Database (Denmark)

    Haji Bashi, Mazaher; Rahmati, Iman; Bak, Claus Leth

    2017-01-01

    Security constraint unit commitment is devised to drive the generation unit schedule in a deregulated environment. Generation bids, transmission system constraints and generation unit constraints are thoroughly considered in this optimization problem. It is acceptable that the transmission system...... normal condition constraints may affect the economic opportunities of the generation companies in the electricity market. Transmission system limitations are the inherent limits of the market environment but this is not true for the generation unit constraints. It means that the generation unit...... constraint of a certain player should not affect the economic opportunities of the rivals. If this happen, generation units can claim to the electricity market regulatory board. In this paper the effect of generation unit constraint on the market outcome is discussed. A fair mechanism is introduced in which...

  18. Informed consent for anaesthesiological and intensive care unit ...

    African Journals Online (AJOL)

    2013-03-04

    Mar 4, 2013 ... care unit research: a South African perspective. De Roubaix JAM, MBChB, .... (g) the development of new applications of health technology. The last two items .... Consent in emergency and ICU care: SA regulatory guidelines.

  19. 77 FR 60481 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Post-Accident...

    Science.gov (United States)

    2012-10-03

    ... filtration and iodine adsorption units of ESF atmosphere cleanup systems in light-water-cooled nuclear power... Filtration and Adsorption Units of Post-Accident Engineered-Safety-Feature Atmosphere Cleanup Systems in Light-Water-Cooled Nuclear Power Plants AGENCY: Nuclear Regulatory Commission. ACTION: Regulatory guide...

  20. 77 FR 50533 - Dominion Nuclear Connecticut, Inc.; Millstone Power Station, Unit 3

    Science.gov (United States)

    2012-08-21

    ....; Millstone Power Station, Unit 3 AGENCY: Nuclear Regulatory Commission. ACTION: Environmental assessment and... search, select ``ADAMS Public Documents'' and then select ``Begin Web- based ADAMS Search.'' For problems... Optimized ZIRLO\\TM\\ fuel rod cladding in future core reload applications for Millstone Power Station, Unit 3...

  1. Competitive Electricity Market Regulation in the United States: A Primer

    Energy Technology Data Exchange (ETDEWEB)

    Flores-Espino, Francisco [National Renewable Energy Lab. (NREL), Golden, CO (United States); Tian, Tian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chernyakhovskiy, Ilya [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chernyakhovskiy, Ilya [National Renewable Energy Lab. (NREL), Golden, CO (United States); Miller, Mackay [National Grid, Warwick (United Kingdom)

    2016-12-01

    The electricity system in the United States is a complex mechanism where different technologies, jurisdictions and regulatory designs interact. Today, two major models for electricity commercialization operate in the United States. One is the regulated monopoly model, in which vertically integrated electricity providers are regulated by state commissions. The other is the competitive model, in which power producers can openly access transmission infrastructure and participate in wholesale electricity markets. This paper describes the origins, evolution, and current status of the regulations that enable competitive markets in the United States.

  2. 77 FR 29701 - Impact of Construction (Under a Combined License) of New Nuclear Power Plant Units on Operating...

    Science.gov (United States)

    2012-05-18

    ... New Nuclear Power Plant Units on Operating Units at Multi-Unit Sites AGENCY: Nuclear Regulatory... construct and operate new nuclear power plants (NPPs) on multi-unit sites to provide an evaluation of the... License) of New Nuclear Power Plants on Operating Units at Multi-Unit Sites (Package). ML112630039 Federal...

  3. Steam generator tube integrity requirements and operating experience in the United States

    International Nuclear Information System (INIS)

    Karwoski, K.J.

    2009-01-01

    Steam generator tube integrity is important to the safe operation of pressurized-water reactors. For ensuring tube integrity, the U.S. Nuclear Regulatory Commission uses a regulatory framework that is largely performance based. This performance-based framework is supplemented with some prescriptive requirements. The framework recognizes that there are three combinations of tube materials and heat treatments currently used in the United States and that the operating experience depends, in part, on the type of material used. This paper summarizes the regulatory framework for ensuring steam generator tube integrity, it highlights the current status of steam generators, and it highlights some of the steam generator issues and challenges that exist in the United States. (author)

  4. Nations United: The United Nations, the United States, and the Global Campaign Against Terrorism. A Curriculum Unit & Video for Secondary Schools.

    Science.gov (United States)

    Houlihan, Christina; McLeod, Shannon

    This curriculum unit and 1-hour videotape are designed to help students understand the purpose and functions of the United Nations (UN) and explore the relationship between the United Nations and the United States. The UN's role in the global counterterrorism campaign serves as a case study for the unit. The students are asked to develop a basic…

  5. 31 CFR 515.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 515.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including the Trust Territory of...

  6. 31 CFR 500.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 500.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including U.S. trust territories...

  7. 31 CFR 535.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 535.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof including the Trust Territory of...

  8. Replacement energy costs for nuclear electricity-generating units in the United States: 1997--2001. Volume 4

    International Nuclear Information System (INIS)

    VanKuiken, J.C.; Guziel, K.A.; Tompkins, M.M.; Buehring, W.A.

    1997-09-01

    This report updates previous estimates of replacement energy costs for potential short-term shutdowns of 109 US nuclear electricity-generating units. This information was developed to assist the US Nuclear Regulatory Commission (NRC) in its regulatory impact analyses, specifically those that examine the impacts of proposed regulations requiring retrofitting of or safety modifications to nuclear reactors. Such actions might necessitate shutdowns of nuclear power plants while these changes are being implemented. The change in energy cost represents one factor that the NRC must consider when deciding to require a particular modification. Cost estimates were derived from probabilistic production cost simulations of pooled utility system operations. Factors affecting replacement energy costs, such as random unit failures, maintenance and refueling requirements, and load variations, are treated in the analysis. This report describes an abbreviated analytical approach as it was adopted to update the cost estimates published in NUREG/CR-4012, Vol. 3. The updates were made to extend the time frame of cost estimates and to account for recent changes in utility system conditions, such as change in fuel prices, construction and retirement schedules, and system demand projects

  9. Barack Obama’s infrastructure policies for the United States

    NARCIS (Netherlands)

    Auger, J.F.

    2008-01-01

    The new president of the United States, Barack Obama, has set his policies on infrastructures. To carry them out, he will resort mostly to economics incentives and, to a lesser extent, regulatory constraints.

  10. Safety improvement programme of WWER 440/230 units in Jaslovske Bohunice

    International Nuclear Information System (INIS)

    Tomek, J.

    2000-01-01

    A brief overview is given of the power sources in Slovakia which include 6 operational reactor units (4 at Jaslovske Bohunice and 2 at Mochovce) and 2 units under construction (at Mochovce). The efforts undertaken in the past 10 years and aimed at upgrading the nuclear safety of the two older (V-230 Soviet type) units at Bohunice are highlighted. The relevant regulatory decisions are dealt with and the measures already carried out are listed. Also characterized are several IAEA international safety assessment missions and safety-aimed meetings which took place in 1998 and 1999 and are of concern to the older Bohunice units. (A.K.)

  11. Construction: first of St. Lucie unit 2 successes

    International Nuclear Information System (INIS)

    Conway, W.F.

    1989-01-01

    The Nuclear Regulatory Commission (NRC) granted a full power operating license for St. Lucie Unit 2 on June 10, 1983, just six years after construction began. The industry average for nuclear power plant construction during this time was approximately ten years. The rate of completion had a positive effect on the cost of the facility. The price of the unit was $1.42 billion as compared to the $2 billion to $5 billion range experienced by other utilities for nuclear plants. These accomplishments were not serendipitous but the results of management techniques and personnel attitudes involved in the construction of the unit. More importantly, many of these same techniques and attitudes have now become part of a quality improvement program at St Lucie and are reflected in its performance indicators. This paper analyzes the construction success of St Lucie Unit 2 and demonstrates that excellent performance in the construction phase can be carried over to the operation of a facility

  12. Radioactive residues at nuclear sites in the United States of America

    International Nuclear Information System (INIS)

    Fiore, J.; Rampertaap, A.; Greeves, J.; MacKinney, J.; Raguso, M.; Selstrom, J.

    2000-01-01

    The United States of America has a large number of sites where radioactive materials have been mined, processed, produced, or used. Upon completion of activities at these sites, some will be cleaned up completely and released for unrestricted future use. However, at other sites, contamination will remain on the site following cleanup, requiring long term institutional controls. Depending on the purpose or the activity conducted at a specific site, these locations are generally under the jurisdiction of a federal agency: the United States Department of Energy, the United States Nuclear Regulatory Commission, the United States Environmental Protection Agency, or the United States Department of Defense. However, under certain conditions, the Nuclear Regulatory Commission relinquishes regulatory authority to individual states to regulate the commercial uses of radioactive materials (except for nuclear reactors), so some locations with radioactive materials are under the jurisdiction of individual states. Other sites with naturally occurring radioactive contamination may also be controlled by individual states. One or two sites under the jurisdiction of each agency are discussed where radioactive materials either existed in the past or exist today, and the source of contamination, the anticipated end state, and the process by which the responsible agency did or will conduct cleanup and site closure are described. Several issues are reviewed that must be addressed in order to design and implement remediations that will ensure long term protection for the environment and future inhabitants. The role of citizens in environmental cleanups is examined, and how institutional controls may be applied to ensure long term protection of remediations that leave some contaminants in place. (author)

  13. 78 FR 47011 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Science.gov (United States)

    2013-08-02

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software... revised regulatory guide (RG), revision 1 of RG 1.171, ``Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants.'' This RG endorses American National Standards...

  14. 77 FR 50722 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Science.gov (United States)

    2012-08-22

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software...) is issuing for public comment draft regulatory guide (DG), DG-1208, ``Software Unit Testing for Digital Computer Software used in Safety Systems of Nuclear Power Plants.'' The DG-1208 is proposed...

  15. The United States nuclear regulatory commission license renewal process

    International Nuclear Information System (INIS)

    Holian, B.E.

    2009-01-01

    The United States (U.S.) Nuclear Regulatory Commission (NRC) license renewal process establishes the technical and administrative requirements for the renewal of operating power plant licenses. Reactor ope-rating licenses were originally issued for 40 years and are allowed to be renewed. The review process for license renewal applications (L.R.A.) provides continued assurance that the level of safety provided by an applicant's current licensing basis is maintained for the period of extended operation. The license renewal review focuses on passive, long-lived structures and components of the plant that are subject to the effects of aging. The applicant must demonstrate that programs are in place to manage those aging effects. The review also verifies that analyses based on the current operating term have been evaluated and shown to be valid for the period of extended operation. The NRC has renewed the licenses for 52 reactors at 30 plant sites. Each applicant requested, and was granted, an extension of 20 years. Applications to renew the licenses of 20 additional reactors at 13 plant sites are under review. As license renewal is voluntary, the decision to seek license renewal and the timing of the application is made by the licensee. However, the NRC expects that, over time, essentially all U.S. operating reactors will request license renewal. In 2009, the U.S. has 4 plants that enter their 41. year of ope-ration. The U.S. Nuclear Industry has expressed interest in 'life beyond 60', that is, requesting approval of a second renewal period. U.S. regulations allow for subsequent license renewals. The NRC is working with the U.S. Department of Energy (DOE) on research related to light water reactor sustainability. (author)

  16. Does size matter? Animal units and animal unit months

    Science.gov (United States)

    Lamar Smith; Joe Hicks; Scott Lusk; Mike Hemmovich; Shane Green; Sarah McCord; Mike Pellant; John Mitchell; Judith Dyess; Jim Sprinkle; Amanda Gearhart; Sherm Karl; Mike Hannemann; Ken Spaeth; Jason Karl; Matt Reeves; Dave Pyke; Jordan Spaak; Andrew Brischke; Del Despain; Matt Phillippi; Dave Weixelmann; Alan Bass; Jessie Page; Lori Metz; David Toledo; Emily Kachergis

    2017-01-01

    The concepts of animal units, animal unit months, and animal unit equivalents have long been used as standards for range management planning, estimating stocking rates, reporting actual use, assessing grazing fees, ranch appraisal, and other purposes. Increasing size of cattle on rangelands has led some to suggest that the definition of animal units and animal unit...

  17. Twenty years of operation of WWER 440/230 units in Jaslovske Bohunice

    International Nuclear Information System (INIS)

    Tomek, J.

    1998-01-01

    It is twenty years this year since the first unit WWER 440 of Slovak Nuclear Power Plant Jaslovske Bohunice was commissioned. There are four units WWER 440 in operation Jaslovske Bohunice site. First two units of older soviet PWR design V-230 (also known as V-1) and other two units of newer V-213 type (also known as V-2). The goal of this presentation is to summarize and evaluate the operation of Unit 1 and 2 for this period of time and mainly to describe what has been done and what is planned to be done to increase the nuclear safety and operational reliability of both units. The operating organization and regulatory authority assume that an internationally acceptable level of safety will be reached by accomplishing of the upgrading program.(author)

  18. A summary of radiological waste disposal practices in the United States and the United Kingdom - 16379

    International Nuclear Information System (INIS)

    Maranville, Victoria M.; McGrath, Richard

    2009-01-01

    A systematic review of near-surface repositories for radioactive waste in the United States (US) was conducted. The main focus of the review consisted of a literature search of available documents and other published sources on low level radioactive waste (LLRW) disposal practices, remediation of LLRW sites in the US, and public participation for remediation efforts of near-surface radiological waste disposal sites in the US. This review was undertaken to provide background information in support of work by the United Kingdom's (UK) Low Level Waste Repository (LLWR) and to aid in optimizing the future management of this site. The review contained a summary of the US and UK radiological waste classification requirements including a discussion of the waste types, disposal requirements, and the differences between US and UK disposal practices. A regulatory overview and evolution of regulatory requirements in the US is presented. The UK regulatory environment is also discussed and contrasted to the US process. The public participation, as part of the US regulatory process, is provided and the mechanism for stakeholder identification and involvement is detailed. To demonstrate how remediation of radiologically impacted sites is implemented in the US, existing US case studies, in which remediation activities were carried out, were reviewed. The following information was compiled: type of wastes disposed of to US shallow ground facilities [with comparison with UK classifications], facility designs (with special emphasis on those directly comparable to the subsurface conditions in the UK), and deficiencies identified in operation or in demonstrating safe post closure; and processes and difficulties in remedial actions encountered at the selected sites. Stakeholder involvement is discussed within the case studies. Publicly available information related to radiological waste management and disposal practices were reviewed. Two sites are presented in this publication for

  19. Operational safety experience reporting in the United States

    International Nuclear Information System (INIS)

    Hartfield, R.A.

    1978-01-01

    Licensees of nuclear power plants in the United States have many reporting requirements included in their technical specifications and the code of federal regulations, title 10. The Nuclear Regulatory Commisson receives these reports and utilizes them in its regulatory program. Part of this usage includes collecting and publishing this operating experience data in various reports and storing information in various data systems. This paper will discuss the data systems and reports on operating experience published and used by the NRC. In addition, some observations on operating experience will be made. Subjects included will be the Licensee Event Report (LER) Data File, the Operating Unit Status Report (Gray Book), Radiation Exposure Reports, Effluents Reports, the Nuclear Plant Reliability Data System, Current Events, Bulletin Wrapups and Annual Summaries. Some of the uses of the reports and systems will be discussed. The Abnormal Occurence Report to the US Congress will also be described and discussed. (author)

  20. Regulations for radiochemical facilities in the United States

    International Nuclear Information System (INIS)

    Emeigh, Ch; Smith, B.; Williams, T

    1999-01-01

    Material control and accounting is implemented to provide assurance that physical protection measures have been effective, and in case they fail, to provide delayed detection of the loss. Regulations in the United States have been developed that include both performance and compliance requirements to provide a defence in depth approach addressing the unique characteristics of each facility. Regulations address administrative controls, material control and material accounting. Nuclear materials control and accounting plans are negotiated between regulatory agencies and facilities to develop a site-specific approach. An overview of the regulations and their implementation in the United State is provided [ru

  1. Rapanos v. United States & Carabell v. United States

    Science.gov (United States)

    Documents associated with guidance for implementing the definition of waters of the United States under the Clean Water Act following the Rapanos v. United States, and Carabell v. United States Supreme Court decision.

  2. Reactor aging research. United States Nuclear Regulatory Commission

    International Nuclear Information System (INIS)

    Vassilaros, M.G.

    1998-01-01

    The reactor ageing research activities in USA described, are focused on the research of reactor vessel integrity, including regulatory issues and technical aspects. Current emphasis are described for fracture analysis, embrittlement research, inspection capabilities, validation od annealing rule, revision of regulatory guide

  3. Ten years of unitization in Brazil; Dez anos de unitizacoes no Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Bonolo, Daniel Dellamora; Almeida, Mateus Passeri de [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil)

    2012-07-01

    The unitization concept, as used by the oil industry, was established in Brazil through Art 27 of the Law 9.478/97, also known as the Petroleum Law, and the first process was initiated in 2002. Within these 10 years, four processes were started and finalized, approved by ANP. These processes were developed in a maturing regulatory environment, which was improved in 2010. This article deals with the peculiarities of these processes, putting in context the regulatory framework and doubts at the time. We also verse about the regulatory scene after 2010, pointing out the main enhancements made. It is concluded that, although essential, an elaborated regulation is not the only important factor for the success of a unitization agreement, but also the agreement between parties, which has been encouraged by ANP.(author)

  4. The impact of environmental regulations on United States crude oil supplies

    International Nuclear Information System (INIS)

    Godec, M.L.; Biglarbigi, K.

    1991-01-01

    A number of legislative and regulatory initiatives being considered to protect the environment could affect the economics of oil and gas exploration and production (E and P) in the Unites States. This paper summarizes the results of a comprehensive assessment of the potential cumulative energy and economic impacts of environmental regulatory initiatives on United States crude oil supplies. The results of the analysis clearly will determine the level of impact, but the results show that significant impacts are felt over a wide range of regulations, over a wide range of crude oil prices, and at two levels of development for extraction technologies. The regulations evaluated all have an impact on all resource categories analyzed in the study

  5. Management and control aimed at reducing potential exposure of cobalt irradiation units

    International Nuclear Information System (INIS)

    Yan Yukui

    2003-01-01

    This paper is intended to address the problems of the management and control of potential exposure of cobalt irradiation units and analyze both the current situation and the resultant accident reasons associated with irradiation units, with the necessary control measures provided to reduce potential exposure. The concepts of defense in depth and excellent engineering practice are introduced in design to provide the units with sufficient redundancy. In the course of scientific management, the qualified applicants or registers devoted, strictly and effectively, their oversight, monitoring and regulation to the irradiation units. The effective management and control are achieved through safety analysis and assessment, reasonable regulatory system and source decommissioning system. (authors)

  6. Interface unit

    NARCIS (Netherlands)

    Keyson, D.V.; Freudenthal, A.; De Hoogh, M.P.A.; Dekoven, E.A.M.

    2001-01-01

    The invention relates to an interface unit comprising at least a display unit for communication with a user, which is designed for being coupled with a control unit for at least one or more parameters in a living or working environment, such as the temperature setting in a house, which control unit

  7. 77 FR 63308 - J. William Foley Incorporated v. United Illuminating Company; Notice of Complaint

    Science.gov (United States)

    2012-10-16

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL12-106-000] J. William Foley Incorporated v. United Illuminating Company; Notice of Complaint Take notice that on October 5...) and 825(e), J. William Foley Incorporated (Complainant) filed a formal complaint against United...

  8. Decommissioning Planning for Nuclear Units at the Oskarshamn Site

    International Nuclear Information System (INIS)

    Rannemalm, Thom; Eriksson, Joergen; Bergh, Niklas

    2016-01-01

    This paper will describe the process that OKG is now in and how the regulatory framework in Sweden is set out with EIA preparation, SAR updates, decommissioning plans etc. and how OKG plans to meet some of the challenges that need to be considered in front of the decommissioning. There will be a discussion on which strategic decisions will have priority and why. The paper will also discuss some of the difficulties with having a site with two units in decommissioning and one unit in power operation. (authors)

  9. 78 FR 77726 - Exelon Generation Company, LLC Three Mile Island Nuclear Station, Unit 1

    Science.gov (United States)

    2013-12-24

    ... Three Mile Island Nuclear Station, Unit 1 AGENCY: Nuclear Regulatory Commission. ACTION: Exemption... License No. DPR-50, which authorizes operation of the Three Mile Island Nuclear Station, Unit 1 (TMI-1... Facility Operating License No. DPR-50, which authorizes operation of the Three Mile Island Nuclear Station...

  10. Food Reformulation, Responsive Regulation, and “Regulatory Scaffolding”: Strengthening Performance of Salt Reduction Programs in Australia and the United Kingdom

    Directory of Open Access Journals (Sweden)

    Roger Magnusson

    2015-06-01

    Full Text Available Strategies to reduce excess salt consumption play an important role in preventing cardiovascular disease, which is the largest contributor to global mortality from non-communicable diseases. In many countries, voluntary food reformulation programs seek to reduce salt levels across selected product categories, guided by aspirational targets to be achieved progressively over time. This paper evaluates the industry-led salt reduction programs that operate in the United Kingdom and Australia. Drawing on theoretical concepts from the field of regulatory studies, we propose a step-wise or “responsive” approach that introduces regulatory “scaffolds” to progressively increase levels of government oversight and control in response to industry inaction or under-performance. Our model makes full use of the food industry’s willingness to reduce salt levels in products to meet reformulation targets, but recognizes that governments remain accountable for addressing major diet-related health risks. Creative regulatory strategies can assist governments to fulfill their public health obligations, including in circumstances where there are political barriers to direct, statutory regulation of the food industry.

  11. Nuclear power reactor licensing and regulation in the United States

    International Nuclear Information System (INIS)

    Shapar, H.K.

    1979-01-01

    The report is devoted to four subjects: an explanation of the origins, statutory basis and development of the present regulatory system in the United States; a description of the various actions which must be taken by a license applicant and by the Nuclear Regulatory Commission before a nuclear power plant can be constructed and placed on-line, an account of the current regulatory practices followed by the US NRC in licensing nuclear power reactors; an identification of some of the 'lessons learned' from the Three Mile Island accident and some proposed regulatory and legislative solutions. (NEA) [fr

  12. Units of measurement past, present and future international system of units

    CERN Document Server

    Gupta, S V

    2010-01-01

    It is for the first time that the subject of quantities and their respective units is dealt this much in detail a glimpse of units of measurements of base quantities of length, time, mass and volume is given for ancient India three and four dimensional systems of measurement units are critically examined establishment of the fact that only four base units are needed to describe a system of units the basics to arrive at the unit of a derived quantity are explained basic, derived and dimensionless quantities including quantity calculus are introduced life history of scientists concerned with measurements units are presented to be inspiring to working metrologists and students. The International System of Units including, Metre Convention Treaty and its various organs including International National of Weights and Measure are described. The realisation of base units is given in detail. Classes of derived units within the SI, units permitted for time to come, units outside SI but used in special fields of measur...

  13. United States position on severe accidents

    International Nuclear Information System (INIS)

    Ross, D.F.

    1988-01-01

    The United States policy on severe accidents was published in 1985 for both new plant applications and for existing plants. Implementation of this policy is in progress. This policy, aided by a related safety goal policy and by analysis capabilities emerging from improved understanding of accident phenomenology, is viewed as a logical development from the pioneering work in the WASH-1400 Reactor Safety Study published by the United States Nuclear Regulatory Commission (NRC) in 1975. This work provided an estimate of the probability and consequences of severe accidents which, prior to that time, had been mostly evaluated by somewhat arbitrary assumptions dating back 30 years. The early history of severe accident evaluation is briefly summarized for the period 1957-1979. Then, the galvanizing action of Three Mile Island Unit 2 (TMI-2) on severe accident analysis, experimentation and regulation is reviewed. Expressions of US policy in the form of rulemaking, severe accident policy, safety research, safety goal policy and court decisions (on adequacy of safety) are discussed. Finally, the NRC policy as of March 1988 is stated, along with a prospective look at the next few years. (author). 19 refs

  14. Impacts of different regulatory regimes in the unitization of production; Impactos dos diferentes regimes regulatorios na individualizacao da producao

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Vinicius Farias; Moreira, Robson Prates [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil)

    2012-07-01

    The unitization process is required in most regulatory models around the world when it identifies that a reservoir straddles to out of the contracted area. This procedure aims to ensure a greater exploitation of petroleum. In Brazil is no different; however there are still many ambiguities in this process. The introduction of new tax regimes in the country broadened the doubts, as we may have a reservoir straddling between concession, production sharing, assignment of rights areas and areas not yet contracted. The objective of the present paper is to explore the uncertainties that must be addressed by the oil and gas sector in order to ensure low legal, regulatory and fiscal risks in the oil industry. The main topics discussed are the rules for production allocation, reserves and expenditures, the ANP and PPSA roles' conflicts, restriction of parties' rights, adjustment of contractual rules and also mitigate or eliminate economic, financial and fiscal uncertainties. This article does not propose solutions to all lacks raised. (author)

  15. A review from the regulatory position of the control of occupational exposure associated with the first 20 years of the United Kingdom commercial nuclear power programme

    International Nuclear Information System (INIS)

    Emmerson, B.W.

    1980-01-01

    The control of occupational exposure received at commercial nuclear generating plants in the United Kingdom has been subject to regulatory requirements embodied in site licence conditions since 1959, and at commercial fuel production and reprocessing plants since 1971. The paper indicates the main radiological control objectives which have applied, reviews the statutory measures introduced for their achievement and indicates some of the administrative arrangements made by site operators in order to comply. The principal sources of occupational exposure associated with each stage of the fuel cycle are identified and exposure data since licensed operations commenced are reviewed. The effectiveness of the United Kingdom site licensing procedure in ensuring adequate radiological control procedures, including the minimisation of occupational exposure, is examined in relation to the relevant ICRP recommendations and against the background of the first 20 years of commercial nuclear power production. The impact on these procedures of more recently introduced legislation relating to health and safety at all places of employment in the United Kingdom is discussed. The paper considers the changes in current regulatory procedures that may result from the introduction of ICRP-26 and the recommendations of ICRP Committee 2, and concludes with a review of the more important problems facing the licensee and the Nuclear Inspectorate with regard to the implementation of future radiological control procedures. (H.K.)

  16. Nuclear safety philosophy in the United Kingdom

    International Nuclear Information System (INIS)

    Anthony, R.D.

    1986-01-01

    Development of the United Kingdom (UK) nuclear safety philosophy is described in the context of the UK nuclear power program since 1959 and of its legislative framework. Basic to the philosophy is that the licensee is wholly responsible for nuclear safety. The licensing process and safety assessment principles used by the Nuclear Installations Inspectorate are discussed, and examples from the assessment of the proposed UK pressurized-water reactor are used to illustrate how the approach works in practice. The UK siting policy and regulatory developments since 1979 are also discussed. Recent, current, and future issues of interest to the regulatory authority are described against the development nuclear scene in the UK

  17. 75 FR 8757 - Nebraska Public Power District, Cooper Nuclear Station, Unit 1; Notice of Availability of the...

    Science.gov (United States)

    2010-02-25

    ..., Cooper Nuclear Station, Unit 1; Notice of Availability of the Draft Supplement 41 to the Generic... Renewal of Cooper Nuclear Station, Unit 1 Notice is hereby given that the U.S. Nuclear Regulatory... operating license DPR-46 for an additional 20 years of operation for Cooper Nuclear Station, Unit 1 (CNS-1...

  18. United States National Seismographic Network

    International Nuclear Information System (INIS)

    Buland, R.

    1993-09-01

    The concept of a United States National Seismograph Network (USNSN) dates back nearly 30 years. The idea was revived several times over the decades. but never funded. For, example, a national network was proposed and discussed at great length in the so called Bolt Report (U. S. Earthquake Observatories: Recommendations for a New National Network, National Academy Press, Washington, D.C., 1980, 122 pp). From the beginning, a national network was viewed as augmenting and complementing the relatively dense, predominantly short-period vertical coverage of selected areas provided by the Regional Seismograph Networks (RSN's) with a sparse, well-distributed network of three-component, observatory quality, permanent stations. The opportunity finally to begin developing a national network arose in 1986 with discussions between the US Geological Survey (USGS) and the Nuclear Regulatory Commission (NRC). Under the agreement signed in 1987, the NRC has provided $5 M in new funding for capital equipment (over the period 1987-1992) and the USGS has provided personnel and facilities to develop. deploy, and operate the network. Because the NRC funding was earmarked for the eastern United States, new USNSN station deployments are mostly east of 105 degree W longitude while the network in the western United States is mostly made up of cooperating stations (stations meeting USNSN design goals, but deployed and operated by other institutions which provide a logical extension to the USNSN)

  19. The United States initiative for international radioactive source management (ISRM)

    International Nuclear Information System (INIS)

    Naraine, N.; Karhnak, J.

    1999-01-01

    The United States takes seriously the potential problems from uncontrolled radioactive sources. To address these problems, the United States Department of State is leading the development of an initiative for International Radioactive Source Management (ISRM). The Department of State, through a number of Federal and state agencies, regulatory bodies and private industry, will endeavor to provide coordinated support to the international community, particularly through IAEA, to assist in the development and implementation of risk-based clearance levels to support import/export of radioactive contaminated metals and the tracking, management, identification, remediation, and disposition of 'lost sources' entering nation states and targeted industries. The United States believes that the international control of radioactive sources is critical in avoiding wide-spread contamination of the world metal supply. Thus the initiative has four objectives: (1) Protect sources from becoming lost (Tracking management); (2) Identify primary locations where sources have been lost (Stop future losses); (3) Locate lost sources (monitor and retrieve); and (4) Educate and train (deploy knowledge and technology). A number of efforts already underway in the United States support the overall initiative. The EPA has provided a grant to the Conference of Radiation Program Control Directors (CRCPD) to develop a nation-wide program for the disposition of orphaned radioactive sources. This program now has internet visibility and a toll-free telephone number to call for assistance in the disposal of sources. The Nuclear Regulatory Commission (NRC), the Department of Energy (DOE), and other government agencies as well as private companies are assisting CRCPD in this program. The NRC has begun a program to improve control of radioactive sources in the United States, and also intends to promulgate a regulation defining conditions for the release of materials from licensed facilities. The DOE is

  20. Simulation of motor unit recruitment and microvascular unit perfusion: spatial considerations.

    Science.gov (United States)

    Fuglevand, A J; Segal, S S

    1997-10-01

    Muscle fiber activity is the principal stimulus for increasing capillary perfusion during exercise. The control elements of perfusion, i.e., microvascular units (MVUs), supply clusters of muscle fibers, whereas the control elements of contraction, i.e., motor units, are composed of fibers widely scattered throughout muscle. The purpose of this study was to examine how the discordant spatial domains of MVUs and motor units could influence the proportion of open capillaries (designated as perfusion) throughout a muscle cross section. A computer model simulated the locations of perfused MVUs in response to the activation of up to 100 motor units in a muscle with 40,000 fibers and a cross-sectional area of 100 mm2. The simulation increased contraction intensity by progressive recruitment of motor units. For each step of motor unit recruitment, the percentage of active fibers and the number of perfused MVUs were determined for several conditions: 1) motor unit fibers widely dispersed and motor unit territories randomly located (which approximates healthy human muscle), 2) regionalized motor unit territories, 3) reversed recruitment order of motor units, 4) densely clustered motor unit fibers, and 5) increased size but decreased number of motor units. The simulations indicated that the widespread dispersion of motor unit fibers facilitates complete capillary (MVU) perfusion of muscle at low levels of activity. The efficacy by which muscle fiber activity induced perfusion was reduced 7- to 14-fold under conditions that decreased the dispersion of active fibers, increased the size of motor units, or reversed the sequence of motor unit recruitment. Such conditions are similar to those that arise in neuromuscular disorders, with aging, or during electrical stimulation of muscle, respectively.

  1. Inspection of licensed nuclear power plants in the United States

    International Nuclear Information System (INIS)

    Thornburg, H. D.

    1977-01-01

    Inspection of licensed nuclear power plants in the United States is performed by the Office of Inspection and Enforcement (IE), United States Nuclear Regulatory Commission. IE has several key functions : a) Inspection of licensees and investigation of incidents, occurrences and allegations. b) Detection and correction of safety and security problems. c) Enforcement of rules, regulations, and Commission orders. d) Feedback to the industry and others regarding safety experience. e) Informing the public and others. Major enforcement actions and events involving operating power reactors for the past several years will be summarized. (author)

  2. Development of Regulatory Audit Programs for Wolsong Unit 1 Continued Operation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong Key; Nho, Seung Hwan; Song, Myung Ho [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2012-05-15

    Wolsong Unit 1 (PHWR type) design life expires on November 20, 2010. In relation to it, KHNP submitted its application to get approval of the MEST on December 30, 2009 and KINS is under review to confirm the appropriateness of continued operation. For the comprehensive review of Wolsong Unit 1 continued operation, KINS has developed the review guidelines for PHWR type reactor including a total of 39 aging management program (AMP) items and 7 time limited aging analysis (TLAA) items. Evaluations or calculations to verify the integrity of nuclear components are required for plant specific AMP and TLAA items as well as the ones specified in the guidelines. In this paper, audit calculation programs developed for KINS staff use in reviewing applicant's submitted evaluation results are presented

  3. United States Nuclear Regulatory Commission staff practice and procedure digest

    International Nuclear Information System (INIS)

    1991-02-01

    This Revision 9 of the fifth edition of the NRC Staff Practice and Procedure Digest contains a digest of a number of Commission, Atomic Safety and Licensing Appeal Board, and Atomic Safety and Licensing Board decisions issued during the period from July 1, 1972 to September 30, 1990 interpreting the NRC's Rules of Practice in 10 CFR Part 2. This Revision 9 replaces in part earlier editions and revisions and includes appropriate changes reflecting the amendments to the Rules of Practice effective through September 30, 1990. This edition of the Digest was prepared by attorneys from Aspen Systems Corporation pursuant to Contract number 18-89-346. Persons using this Digest are placed on notice that it may not be used as an authoritative citation in support of any position before the Commission or any of its adjudicatory tribunals. Persons using this Digest are also placed on notice that it is intended for use only as an initial research tool, that it may, and likely does, contain errors, including errors in analysis and interpretation of decisions, and that the user should not rely on the Digest analyses and interpretations but must read, analyze and rely on the user's own analysis of the actual Commission, Appeal Board and Licensing Board decisions cited. Further, neither the United States, the Nuclear Regulatory Commission, Aspen Systems Corporation, nor any of their employees makes any expressed or implied warranty or assumes liability or responsibility for the accuracy, completeness or usefulness of any material presented in the Digest. The Digest is roughly structured in accordance with the chronological sequence of the nuclear facility licensing process as set forth in Appendix A to 10 CFR Part 2. Those decisions which did not fit into that structure are dealt with in a section on general matters. Where appropriate, particular decisions are indexed under more than one heading. (JF)

  4. 78 FR 65007 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3

    Science.gov (United States)

    2013-10-30

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00026; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion...

  5. Genome-Wide Mapping of Transcriptional Regulation and Metabolism Describes Information-Processing Units in Escherichia coli

    Directory of Open Access Journals (Sweden)

    Daniela Ledezma-Tejeida

    2017-08-01

    Full Text Available In the face of changes in their environment, bacteria adjust gene expression levels and produce appropriate responses. The individual layers of this process have been widely studied: the transcriptional regulatory network describes the regulatory interactions that produce changes in the metabolic network, both of which are coordinated by the signaling network, but the interplay between them has never been described in a systematic fashion. Here, we formalize the process of detection and processing of environmental information mediated by individual transcription factors (TFs, utilizing a concept termed genetic sensory response units (GENSOR units, which are composed of four components: (1 a signal, (2 signal transduction, (3 genetic switch, and (4 a response. We used experimentally validated data sets from two databases to assemble a GENSOR unit for each of the 189 local TFs of Escherichia coli K-12 contained in the RegulonDB database. Further analysis suggested that feedback is a common occurrence in signal processing, and there is a gradient of functional complexity in the response mediated by each TF, as opposed to a one regulator/one pathway rule. Finally, we provide examples of other GENSOR unit applications, such as hypothesis generation, detailed description of cellular decision making, and elucidation of indirect regulatory mechanisms.

  6. Audit Calculations of LBLOCA for Ulchin Unit 1 and 2 Power Up rate

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Donggu; Huh, Byunggil; Yoo, Seunghunl; Yang, Chaeyong; Seul, Kwangwon [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-05-15

    The KINS-Realistic Evaluation Model (KINS-REM) was developed for the independent audit calculation in 1991, and the code accuracy and statistical method have been improved. To support the licensing review and to confirm the validity of licensee's calculation, regulatory auditing calculations have been also conducted. Currently, the modification of Ulchin 1 and 2 operating license for 4.5% power up rate is under review. In this study, the regulatory audit calculation for LBLOCA of Ulchin Unit 1 and 2 with 4.5% power up rate was performed by applying KINS-REM. In this study, the regulatory audit calculation for LBLOCA of Ulchin Unit 1 and 2 with 4.5% power up rate was performed by applying KINS-REM. It is confirmed that the analysis results of LBLOCA for Ulchin 1 and 2 power up rate meets the PCT acceptance criteria.

  7. 78 FR 53483 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3

    Science.gov (United States)

    2013-08-29

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00025; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria (ITAAC) completion...

  8. 78 FR 53484 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 4

    Science.gov (United States)

    2013-08-29

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00026; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 4 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria (ITAAC) completion...

  9. Generation unit selection via capital asset pricing model for generation planning

    Energy Technology Data Exchange (ETDEWEB)

    Romy Cahyadi; K. Jo Min; Chung-Hsiao Wang; Nick Abi-Samra [College of Engineering, Ames, IA (USA)

    2003-11-01

    The USA's electric power industry is undergoing substantial regulatory and organizational changes. Such changes introduce substantial financial risk in generation planning. In order to incorporate the financial risk into the capital investment decision process of generation planning, this paper develops and analyses a generation unit selection process via the capital asset pricing model (CAPM). In particular, utilizing realistic data on gas-fired, coal-fired, and wind power generation units, the authors show which and how concrete steps can be taken for generation planning purposes. It is hoped that the generation unit selection process will help utilities in the area of effective and efficient generation planning when financial risks are considered. 20 refs., 14 tabs.

  10. Medical Device Regulation: A Comparison of the United States and the European Union.

    Science.gov (United States)

    Maak, Travis G; Wylie, James D

    2016-08-01

    Medical device regulation is a controversial topic in both the United States and the European Union. Many physicians and innovators in the United States cite a restrictive US FDA regulatory process as the reason for earlier and more rapid clinical advances in Europe. The FDA approval process mandates that a device be proved efficacious compared with a control or be substantially equivalent to a predicate device, whereas the European Union approval process mandates that the device perform its intended function. Stringent, peer-reviewed safety data have not been reported. However, after recent high-profile device failures, political pressure in both the United States and the European Union has favored more restrictive approval processes. Substantial reforms of the European Union process within the next 5 to 10 years will result in a more stringent approach to device regulation, similar to that of the FDA. Changes in the FDA regulatory process have been suggested but are not imminent.

  11. Annual dose at the exclusion area boundary of a multi-unit CANDU site

    International Nuclear Information System (INIS)

    Gagnon, N.; Bobb, C.R.; Tsang, K.T.

    1997-01-01

    The annual dose to members of the public from CANDU nuclear power stations is dominated by the contribution from airborne effluents. The principal radionuclides contributing to the annual dose are tritium, carbon-14 and noble gases. The tritium is released as tritiated heavy-water vapour; the carbon-14 is released principally as carbon dioxide. To demonstrate compliance with the public dose limit, AECL has calculated the annual dose from airborne emissions from 10 CANDU units at an extended Wolsong site. The analysis has used the treatment of atmospheric dispersion described in the US Regulatory Guide 1.111 and programmed in the code XOQDOQ. The analysis has then modelled the transport of these airborne emissions through the environment as they expose the critical group using the US Regulatory Guide 1.109. the study takes account of the different annual emissions from each unit to reflect the different design features of the units. This study also includes a treatment of topography and makes allowances for building wake effects

  12. 78 FR 38411 - Vogtle Electric Generating Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria

    Science.gov (United States)

    2013-06-26

    ... Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) staff has determined that the inspections, tests...

  13. NPP Cernavoda unit 2 economic viability: The challenge for an advanced financing scheme

    International Nuclear Information System (INIS)

    Condu, M.; Popescu, D.

    1999-01-01

    The completion of Cernavoda Unit-2 being no doubt, the viability of the project was analyzed and strengthened. Economic justification of the decision to complete Unit-2 is described, including assessment of its safety design guides, design requirements and engineering design solutions in the light of changes in codes, guideline, standards and actual regulatory requirements. Cost-benefit analysis demonstrates the economic viability of the project

  14. Regulatory analysis for the resolution of Generic Issue 130: Essential service water system failures at multi-unit sites

    International Nuclear Information System (INIS)

    Leung, V.; Basdekas, D.; Mazetis, G.

    1991-06-01

    The essential service water system (ESWS) is required to provide cooling in nuclear power plants during normal operation and accident conditions. The ESWS typically supports component cooling water heat exchangers, containment spray heat exchangers, high-pressure injection pump oil coolers, emergency diesel generators, and auxiliary building ventilation coolers. Failure of the ESWS function could lead to severe consequences. This report presents the regulatory analysis for GI-130, ''Essential Service Water System Failures at Multi-Unit Sites.'' The risk reduction estimates, cost/benefit analyses, and other insights gained during this effort have shown that implementation of the recommendations will significantly reduce risk and that these improvements are warranted in accordance with the backfit rule, 10 CFR 50.109(a)(3). 19 refs., 16 tabs

  15. The regulation in the unitization process in the petroleum and natural gas exploration in Brazil; A regulacao no processo de unitization na exploracao de petroleo e gas natural no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Felipe Alvite; Silva, Moises Espindola [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Engenharia de Petroleo; Bone, Rosemarie Broeker [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Engenharia de Producao

    2008-07-01

    This paper presents and analyses the unitization of exploration and production process of petroleum and natural gas in Brazil, focusing the regulatory aspects under the Petroleum Law 9478/97. Considering the deficiency and blanks of the existent regulation when referring the utilization, this work intends to present and discuss those non resolved points and, in concise way, to present international unitization cases, applying when possible, their resolutions to Brazil.

  16. Continental integration and energy demand in the United States

    International Nuclear Information System (INIS)

    Manning, D.J.

    2004-01-01

    This presentation highlighted some of the major issues regarding energy demand in the United States and continental integration. The energy markets in Canada and the United States are economically integrated with large cross-border investment. Therefore, the energy infrastructure can be significantly affected by inconsistencies between the two countries in policy, regulatory processes and fiscal regimes. The author discussed the inelasticity in the natural gas demand in the United States in the near-term, and how natural gas consumption, particularly for power generation, is greater than North America's supply capacity. New supplies such as liquefied natural gas and arctic gas are needed to meet growing demands. The role of renewable energy technologies and energy efficiency was also discussed. It was emphasized that imbalances in supply and demand inevitably lead to price volatility and that high prices are a major obstacle to economic growth. tabs., figs

  17. 77 FR 38857 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Normal...

    Science.gov (United States)

    2012-06-29

    ... Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water- Cooled Nuclear Power... Criteria for Air Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water-Cooled... draft regulatory guide (DG), DG-1280, ``Design, Inspection, and Testing Criteria for Air Filtration and...

  18. Planning for closures of hazardous waste land disposal units at the Oak Ridge Y-12 plant

    International Nuclear Information System (INIS)

    Welch, S.H.; Kelly, B.A.; DeLozier, M.F.P.; Manrod, W.E.

    1988-01-01

    Eight hazardous waste land disposal units at the Oak Ridge Y-12 Plant are being closed in accordance with the Resource Conservation and Recovery Act (RCRA) under an integrated multi-year program. The units, some of which date back to the early 1950s and include five surface impoundments, two landfills and a land treatment unit, have been used for the management of a variety of types of hazardous wastes. Closure plans for the units have been submitted and are in various stages of revision and regulatory review. The units will be closed by various combinations of methods, including liquid removal and treatment, sludge stabilization, contaminated sludge and/or soil removal, and capping. Closure of all eight units must be initiated by November 8, 1988. Funding for the eight closures is being provided by a new Department of Energy budget category, the environmental Restoration Budget Category (ERBC), which is intended to allow for a more rapid response to environmental problems and regulatory requirements. A major project, Closure and Post-Closure Activities (CAPCA) has been identified for ERBC funding to close the land disposal units in accordance with RCRA requirements. Establishing the project scope has required the development of a detailed set of assumptions and a confirmation program for each assumption. Other significant activities in the CAPCA project include risk assessments and the preparation of an integrated project schedule

  19. The regulatory approach to the assessment of containment structures in the United Kingdom, with reference to the proposed Sizewell 'B' project

    International Nuclear Information System (INIS)

    Todd, I.W.

    1988-01-01

    The regulation of nuclear installations in the United Kingdom is carried out by means of a licensing system which is administered on behalf of the Health and Safety Executive (HSE) by HM Nuclear Installations Inspectorate. A major part of this process lies in the assessment of an installation's designs and safety case, which must be submitted to the Inspectorate before a licence may be granted. This paper describes the work carried out in assessing the design proposed for the containment structure of the United Kingdom's first PWR, Sizewell 'B'. The roles of the Inspectorate's Safety Assessment Principles, and the engineering judgement of the individual assessor, are discussed. The reasons behind the Inspectorate's decision to commission independent design studies of the structure are explained, and the results of these studies are presented in outline. Views are also expressed upon the validation of analytical results, quality assurance, and further work planned by the Inspectorate in this field. The paper concludes that it is the flexibility and discretion allowed by the above approach which represents the principal strength of the UK's system of regulatory assessment. (author)

  20. 76 FR 24538 - Duke Energy Carolinas, LLC; Catawba Nuclear Station, Units 1 and 2; McGuire Nuclear Station...

    Science.gov (United States)

    2011-05-02

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-413 and 50-414; NRC-2011-0100; Docket Nos. 50-369 and 50-370; Docket Nos. 50-269, 50-270, and 50-287] Duke Energy Carolinas, LLC; Catawba Nuclear Station, Units 1 and 2; McGuire Nuclear Station, Units 1 and 2; Oconee Nuclear Station, Units 1, 2, and 3...

  1. Steam generator replacement in Bruce A Unit 1 and Unit 2

    International Nuclear Information System (INIS)

    Hart, R.S.

    2006-01-01

    The Bruce A Generating Station consists of four 900 MW class CANDU units. The reactor and Primary Heat Transport System for each Unit are housed within a reinforced concrete reactor vault. A large duct running below the reactor vaults accommodates the shared fuel handling system, and connects the four reactor vaults to the vacuum building. The reactor vaults, fuelling system duct and the vacuum building constitute the station vacuum containment system. Bruce A Unit 2 was shut down in 1995 and Bruce A Units 1, 3 and 4 were shutdown in 1997. Bruce A Units 3 and 4 were returned to service in late 2003 and are currently operating. Units 1 and 2 remain out of service. Bruce Power is currently undertaking a major rehabilitation of Bruce A Unit 1 and Units 2 that will extend the in-service life of these units by at least 25 years. Replacement of the Steam Generators (eight in each unit) is required; this work was awarded to SNC-Lavalin Nuclear (SLN). The existing steam drums (which house the steam separation and drying equipment) will be retained. Unit 2 is scheduled to be synchronized with the grid in 2009, followed by Unit 1 in 2009. Each Bruce A unit has two steam generating assemblies, one located above and to each end of the reactor. Each steam generating assembly consists of a horizontal cylindrical steam drum and four vertical Steam Generators. The vertical Steam Generators connect to individual nozzles that are located on the underside of the Steam Drum (SD). The steam drums are located in concrete shielding structures (steam drum enclosures). The lower sections of the Steam Generators penetrate the top of the reactor vaults: the containment pressure boundary is established by bellows assemblies that connect between the reactor vault roof slab and the Steam Generators. Each Steam Generators is supported from the bottom by a trapeze that is suspended from the reactor vault top structure. The Steam Generator Replacement (SGR) methodology developed by SLN for Unit 1

  2. Comparative analysis of LMFBR licensing in the United States and other countries - notably France. Executive summary

    International Nuclear Information System (INIS)

    Golay, M.W.; Castillo, M.

    1981-01-01

    The safety-related design aspects and licensing experiences of LMFBR projects in other democratic countries have been studied and contrasted to those in the United States in order to understand the importance of different approaches to safety, and also to understand better the system of the United States. The regulatory systems and LMFBR programs of France and the United States are contrasted in detail, and that of West Germany is also studied. The programs of Japan and the United Kingdom receive considerably less attention, and that of the Soviet Union is ignored

  3. Generation unit selection via capital asset pricing model for generation planning

    Energy Technology Data Exchange (ETDEWEB)

    Cahyadi, Romy; Jo Min, K. [College of Engineering, Ames, IA (United States); Chunghsiao Wang [LG and E Energy Corp., Louisville, KY (United States); Abi-Samra, Nick [Electric Power Research Inst., Palo Alto, CA (United States)

    2003-07-01

    The electric power industry in many parts of U.S.A. is undergoing substantial regulatory and organizational changes. Such changes introduce substantial financial risk in generation planning. In order to incorporate the financial risk into the capital investment decision process of generation planning, in this paper, we develop and analyse a generation unit selection process via the capital asset pricing model (CAPM). In particular, utilizing realistic data on gas-fired, coal-fired, and wind power generation units, we show which and how concrete steps can be taken for generation planning purposes. It is hoped that the generation unit selection process developed in this paper will help utilities in the area of effective and efficient generation planning when financial risks are considered. (Author)

  4. Case Study of Multi-Unit Risk: Multi-Unit Station Black-Out

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Kyemin; Jang, Seung-cheol [KAERI, Daejeon (Korea, Republic of); Heo, Gyunyoung [Kyung Hee University, Yongin (Korea, Republic of)

    2015-05-15

    After Fukushima Daiichi Accident, importance and public concern for Multi-Unit Risk (MUR) or Probabilistic Safety Assessment (PSA) have been increased. Most of nuclear power plant sites in the world have more than two units. These sites have been facing the problems of MUR or accident such as Fukushima. In case of South Korea, there are generally more than four units on the same site and even more than ten units are also expected. In other words, sites in South Korea also have been facing same problems. Considering number of units on the same site, potential of these problems may be larger than other countries. The purpose of this paper is to perform case study based on another paper submitted in the conference. MUR is depended on various site features such as design, shared systems/structures, layout, environmental condition, and so on. Considering various dependencies, we assessed Multi-Unit Station Black-out (MSBO) accident based on Hanul Unit 3 and 4 model. In this paper, case study for multi-unit risk or PSA had been performed. Our result was incomplete to assess total multi-unit risk because of two challenging issues. First, economic impact had not been evaluated to estimate multi-unit risk. Second, large uncertainties were included in our result because of various assumptions. These issues must be resolved in the future.

  5. Case Study of Multi-Unit Risk: Multi-Unit Station Black-Out

    International Nuclear Information System (INIS)

    Oh, Kyemin; Jang, Seung-cheol; Heo, Gyunyoung

    2015-01-01

    After Fukushima Daiichi Accident, importance and public concern for Multi-Unit Risk (MUR) or Probabilistic Safety Assessment (PSA) have been increased. Most of nuclear power plant sites in the world have more than two units. These sites have been facing the problems of MUR or accident such as Fukushima. In case of South Korea, there are generally more than four units on the same site and even more than ten units are also expected. In other words, sites in South Korea also have been facing same problems. Considering number of units on the same site, potential of these problems may be larger than other countries. The purpose of this paper is to perform case study based on another paper submitted in the conference. MUR is depended on various site features such as design, shared systems/structures, layout, environmental condition, and so on. Considering various dependencies, we assessed Multi-Unit Station Black-out (MSBO) accident based on Hanul Unit 3 and 4 model. In this paper, case study for multi-unit risk or PSA had been performed. Our result was incomplete to assess total multi-unit risk because of two challenging issues. First, economic impact had not been evaluated to estimate multi-unit risk. Second, large uncertainties were included in our result because of various assumptions. These issues must be resolved in the future

  6. Regulatory practices - United States example

    International Nuclear Information System (INIS)

    Shapar, M.

    1976-01-01

    In 1954, the Atomic Energy Act of 1946 was revised to do away with the federal state monopoly in this field and to enable private industry to develop nuclear power. This evolution led the federal authorities to give the Atomic Energy Commission the powers to control the design, licensing and operation of nuclear reactors. These powers were constantly strengthened and are now exercised by the Nuclear Regulatory Commission (NRC). Since its creation in 1975, the Commission has amended the regulations on licensing of nuclear reactors in the light of experience acquired so as to shorten the duration of this procedure. These amendments concern the standardization of nuclear power plants, limited work authorizations, the methods for issuing licenses. The objective of the Commission aim to make the licensing procedure for nuclear power plants simpler and more efficient and hence, less costly, while ensuring that a very high level for safety standards and environmental protection is maintained. (NEA) [fr

  7. 1:250,000-scale Hydrologic Units of the United States

    Science.gov (United States)

    Steeves, Peter; Nebert, Douglas

    1994-01-01

    The Geographic Information Retrieval and Analysis System (GIRAS) was developed in the mid 70s to put into digital form a numberof data layers which were of interest to the USGS. One of these data layers was the Hydrologic Units. The map is based on the Hydrologic Unit Maps published by the U.S. Geological Survey Office of Water Data Coordination, together with the list descriptions and name of region, subregion, accounting units, and cataloging unit. The hydrologic units are encoded with an eight-digit number that indicates the hydrologic region (first two digits), hydrologic subregion (second two digits), accounting unit (third two digits), and cataloging unit (fourth two digits). The data produced by GIRAS was originally collected at a scale of 1:250K. Some areas, notably major cities in the west, were recompiled at a scale of 1:100K. In order to join the data together and use the data in a geographic information system (GIS) the data were processed in the ARC/INFO GUS software package. Within the GIS, the data were edgematched and the neatline boundaries between maps were removed to create a single data set for the conterminous

  8. 76 FR 78805 - Regulatory Changes To Implement the United States/Australian Agreement for Peaceful Nuclear...

    Science.gov (United States)

    2011-12-20

    ... Implement the United States/Australian Agreement for Peaceful Nuclear Cooperation; Corrections AGENCY... the Government of Australia and the Government of the United States of America Concerning Peaceful... action is unnecessary. List of Subjects in 10 CFR Part 40 Criminal penalties, Government contracts...

  9. 76 FR 69120 - Regulatory Changes To Implement the United States/Australian Agreement for Peaceful Nuclear...

    Science.gov (United States)

    2011-11-08

    ... Government of the United States of America Concerning Peaceful Uses of Nuclear Energy'' (the Agreement). The... applicable requirements. Environmental Assessment: Finding of No Significant Environmental Impact The NRC has... and the Government of the United States of America Concerning Peaceful Uses of Nuclear Energy, dated...

  10. 77 FR 35079 - License Renewal Application for Seabrook Station, Unit 1 ; NextEra Energy Seabrook, LLC

    Science.gov (United States)

    2012-06-12

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-443; NRC-2010-0206] License Renewal Application for Seabrook Station, Unit 1 ; NextEra Energy Seabrook, LLC AGENCY: Nuclear Regulatory Commission. ACTION: License renewal application; intent to prepare supplement to draft [[Page 35080

  11. Review of Technical Studies in the United States in Support of Burnup Credit Regulatory Guidance

    International Nuclear Information System (INIS)

    Wagner, John C.; Parks, Cecil V.; Mueller, Don; Gauld, Ian C.

    2010-01-01

    Taking credit for the reduction in reactivity associated with fuel depletion can enable more cost-effective, higher-density storage, transport, disposal, and reprocessing of spent nuclear fuel (SNF) while maintaining sufficient subcritical margin to establish an adequate safety basis. Consequently, there continues to be considerable interest in the United States (U.S.), as well as internationally, in the increased use of burnup credit in SNF operations, particularly related to storage, transport, and disposal of commercial SNF. This interest has motivated numerous technical studies related to the application of burnup credit, both domestically and internationally, as well as the design of SNF storage, transport and disposal systems that rely on burnup credit for maintaining subcriticality. Responding to industry requests and needs, the U.S. Nuclear Regulatory Commission (NRC) initiated a burnup credit research program in 1999, with support from the Oak Ridge National Laboratory (ORNL), to develop regulatory guidance and the supporting technical bases for allowing and expanding the use of burnup credit in pressurized-water reactor SNF storage and transport applications. Although this NRC research program has not been continuous since its inception, considerable progress has been achieved in many key areas in terms of increased understanding of relevant phenomena and issues, availability of relevant information and data, and subsequently updated regulatory guidance for expanded use of burnup credit. This paper reviews technical studies performed by ORNL for the U.S. NRC burnup credit research program. Examples of topics include reactivity effects associated with reactor operating characteristics, fuel assembly characteristics, burnable absorbers, control rods, spatial burnup distributions, cooling time, and assembly misloading; methods and data for validation of isotopic composition predictions; methods and data for validation of criticality calculations; and

  12. Multi-Unit Initiating Event Analysis for a Single-Unit Internal Events Level 1 PSA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong San; Park, Jin Hee; Lim, Ho Gon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The Fukushima nuclear accident in 2011 highlighted the importance of considering the risks from multi-unit accidents at a site. The ASME/ANS probabilistic risk assessment (PRA) standard also includes some requirements related to multi-unit aspects, one of which (IE-B5) is as follows: 'For multi-unit sites with shared systems, DO NOT SUBSUME multi-unit initiating events if they impact mitigation capability [1].' However, the existing single-unit PSA models do not explicitly consider multi-unit initiating events and hence systems shared by multiple units (e.g., alternate AC diesel generator) are fully credited for the single unit and ignores the need for the shared systems by other units at the same site [2]. This paper describes the results of the multi-unit initiating event (IE) analysis performed as a part of the at-power internal events Level 1 probabilistic safety assessment (PSA) for an OPR1000 single unit ('reference unit'). In this study, a multi-unit initiating event analysis for a single-unit PSA was performed, and using the results, dual-unit LOOP initiating event was added to the existing PSA model for the reference unit (OPR1000 type). Event trees were developed for dual-unit LOOP and dual-unit SBO which can be transferred from dual- unit LOOP. Moreover, CCF basic events for 5 diesel generators were modelled. In case of simultaneous SBO occurrences in both units, this study compared two different assumptions on the availability of the AAC D/G. As a result, when dual-unit LOOP initiating event was added to the existing single-unit PSA model, the total CDF increased by 1∼ 2% depending on the probability that the AAC D/G is available to a specific unit in case of simultaneous SBO in both units.

  13. SI units in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Iyer, P S [Bhabha Atomic Research Centre, Bombay (India). Div. of Radiation Protection

    1978-11-01

    The proposal of the International Commission on Radiation Units and Measurements that the special units of radiation and radioactivity-roentgen, rad, rem and curie-be replaced by the International System (SI) of Units has been accepted by international bodies. This paper reviews the resons for introducing the new units and their features. The relation between the special units and the corresponding SI units is discussed with examples. In spite of anticipated difficulties, the commission recommends a smooth and efficient changeover to the SI units in ten years.

  14. License renewal in the United States

    International Nuclear Information System (INIS)

    Brons, Jack

    2002-01-01

    Full text: Nuclear plants in the United States are licensed for 40 years, a length specified in the Atomic Energy Act of 1954, which laid out much of the regulatory basis for the commercial nuclear industry. The Act, however, made provision for license renewal. The original 40-year license period was chosen arbitrarily by the U.S. Congress because it was the typical period over which utilities recovered their investment in electricity generating plants. Nuclear plants, however, are subject to a rigorous program of Nuclear Regulatory Commission oversight, maintenance and equipment replacement. In effect, they must be in the same operating condition on the last day of their licenses as they were on the first. As the industry matured, it became apparent that there was no physical limitation on the continued operation of nuclear plants past 40 years. The industry turned its attention toward license renewal. When the issue was first raised, the NRC considered stringent process equivalent to seeking a new operating license for each plant. The complexity, length and cost of the process made it unlikely that many nuclear plants would seek license renewal. The nuclear industry worked successfully with NRC on the application of generic principles to license renewal, however, and in 1995, the NRC issued an efficient, tightly-focused rule that made license renewal a safe, viable option. To extend the operating license for a reactor, a company must demonstrate to the NRC that aging effects will be adequately managed during the renewal terms, thus ensuring equipment functionality. The rule allows licensees to apply for extensions of up to 20 years. The first license renewal application was filed in 1998 by the owner of the two-unit Calvert Cliffs plant. Shortly thereafter, an application was filed for the three-unit Oconee Nuclear Station. The NRC renewed the licenses for all five units in 2000, and since then, five more licenses have been renewed. The NRC has received 37

  15. Tube structural integrity evaluation of Palo Verde Unit 1 steam generators for axial upper-bundle cracking

    International Nuclear Information System (INIS)

    Woodman, B.W.; Begley, J.A.; Brown, S.D.; Sweeney, K.; Radspinner, M.; Melton, M.

    1995-01-01

    The analysis of the issue of upper bundle axial ODSCC as it apples to steam generator tube structural integrity in Unit 1 at the Palo Verde Nuclear generating Station is presented in this study. Based on past inspection results for Units 2 and 3 at Palo Verde, the detection of secondary side stress corrosion cracks in the upper bundle region of Unit 1 may occur at some future date. The following discussion provides a description and analysis of the probability of axial ODSCC in Unit 1 leading to the exceedance of Regulatory Guide 1.121 structural limits. The probabilities of structural limit exceedance are estimated as function of run time using a conservative approach. The chosen approach models the historical development of cracks, crack growth, detection of cracks and subsequent removal from service and the initiation and growth of new cracks during a given cycle of operation. Past performance of all Palo Verde Units as well as the historical performance of other steam generators was considered in the development of cracking statistics for application to Unit 1. Data in the literature and Unit 2 pulled tube examination results were used to construct probability of detection curves for the detection of axial IGSCC/IGA using an MRPC (multi-frequency rotating panake coil) eddy current probe. Crack growth rates were estimated from Unit 2 eddy current inspection data combined with pulled tube examination results and data in the literature. A Monte-Carlo probabilistic model is developed to provide an overall assessment of the risk of Regulatory Guide exceedance during plant operation

  16. 78 FR 79709 - Duke Energy Florida, Inc., Crystal River Unit 3 Nuclear Generating Plant Post-Shutdown...

    Science.gov (United States)

    2013-12-31

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-302; NRC-2013-0283] Duke Energy Florida, Inc., Crystal River Unit 3 Nuclear Generating Plant Post-Shutdown Decommissioning Activities Report AGENCY: Nuclear Regulatory Commission (NRC). ACTION: Notice of receipt; availability; public meeting; and request...

  17. 76 FR 71510 - Meeting of the Assembly of the Administrative Conference of the United States

    Science.gov (United States)

    2011-11-18

    ... administrative agencies, the President, Congress, and the Judicial Conference of the United States regarding the... participation and efficiency in the rulemaking process, reduce unnecessary litigation in the regulatory process, improve the use of science in the regulatory process, and improve the effectiveness of laws applicable to...

  18. 75 FR 43571 - Duke Energy Carolinas, LLC; Catawba Nuclear Station, Units 1 and 2; Environmental Assessment And...

    Science.gov (United States)

    2010-07-26

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-413 and 50-414; NRC-2010-0260] Duke Energy Carolinas, LLC; Catawba Nuclear Station, Units 1 and 2; Environmental Assessment And Finding of No Significant... Energy Carolinas, LLC (the licensee), for operation of the Catawba Nuclear Station, Units 1 and 2...

  19. 75 FR 82414 - Carolina Power & Light Company; H. B. Robinson Steam Electric Plant, Unit No. 2; Exemption

    Science.gov (United States)

    2010-12-30

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-261; NRC-2010-0062] Carolina Power & Light Company; H. B. Robinson Steam Electric Plant, Unit No. 2; Exemption 1.0 Background Carolina Power & Light... authorizes operation of the H.B. Robinson Steam Electric Plant, Unit 2 (HBRSEP). The license provides, among...

  20. 75 FR 11579 - Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2; Exemption

    Science.gov (United States)

    2010-03-11

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-261; NRC-2010-0062] Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2; Exemption 1.0 Background Carolina Power & Light... of the H. B. Robinson Steam Electric Plant, Unit 2 (HBRSEP). The license provides, among other things...

  1. Brucellosis in the United States: Role and Significance of Wildlife Reservoirs

    Science.gov (United States)

    Regulatory programs for brucellosis in domestic livestock have been active in the United States for almost 80 years. Wildlife reservoirs of brucellosis include bison (Bison bison) and elk (Cervus elaphus nelsonii) for B. abortus whereas B. suis is the predominant species infecting feral swine. The...

  2. RCRA closure of eight land-based units at the Y-12 plant

    International Nuclear Information System (INIS)

    Stone, J.E.; Welch, S.H.

    1988-01-01

    Eight land-based hazardous waste management units at the Oak Ridge Y-12 Plant are being closed under an integrated multi-year program. Closure plans for the units have been submitted and are in various stages of revision and regulatory review. These units will be closed by various combinations of methods, including liquid removal and treatment, sludge stabilization, contaminated sludge and/or soil removal, and capping. The closure of these sites will be funded by a new Department of Energy budget category, the Environmental Restoration Budget Category (ERBC), which is intended to provide greater flexibility in the response to closure and remedial activities. A major project, Closure and Post-Closure Activities (CAPCA), has been identified for ERBC funding to close and remediate the land units in accordance with RCRA requirements. Establishing the scope of this program has required the development of risk assessments and the preparation of an integrated schedule

  3. Pacific Northwest National Laboratory Facility Radionuclide Emissions Units and Sampling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, J. Matthew; Brown, Jason H.; Walker, Brian A.

    2012-04-01

    Battelle–Pacific Northwest Division operates numerous research and development (R&D) laboratories in Richland, WA, including those associated with Pacific Northwest National Laboratory (PNNL) on the U.S. Department of Energy (DOE)’s Hanford Site and PNNL Site that have the potential for radionuclide air emissions. The National Emission Standard for Hazardous Air Pollutants (NESHAP 40 CFR 61, Subparts H and I) requires an assessment of all emission units that have the potential for radionuclide air emissions. Potential emissions are assessed annually by PNNL staff members. Sampling, monitoring, and other regulatory compliance requirements are designated based upon the potential-to-emit dose criteria found in the regulations. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled systems, a description of the buildings, exhaust units, control technologies, and sample extraction details is provided for each registered emission unit. Additionally, applicable stack sampler configuration drawings, figures, and photographs are provided. Deregistered emission unit details are provided as necessary for up to 5 years post closure.

  4. Discharge from an emergency department observation unit and a surgical assessment unit

    DEFF Research Database (Denmark)

    Schultz, Helen; Qvist, Niels; Backer Mogensen, Christian

    2014-01-01

    To investigate the experiences of patients with acute abdominal pain at discharge from an emergency department observation unit compared with discharge from a surgical assessment unit.......To investigate the experiences of patients with acute abdominal pain at discharge from an emergency department observation unit compared with discharge from a surgical assessment unit....

  5. Technical specifications: Seabrook Station, Unit 1 (Docket No. 50-443)

    International Nuclear Information System (INIS)

    1990-03-01

    The Seabrook Station, Unit 1 Technical Specifications were prepared by the US Nuclear Regulatory Commission to set forth the limits, operating conditions, and other requirements applicable to a nuclear reactor facility as set forth in Section 50.36 of 10 CFR Part 50 for the protection of the health and safety of the public

  6. Evaluation of River Bend Station Unit 1 Technical Specifications

    International Nuclear Information System (INIS)

    Baxter, D.E.; Bruske, S.J.

    1985-08-01

    This document was prepared for the Nuclear Regulatory Commission (NRC) to assist them in determining whether the River Bend Station Unit 1 Technical Specifications (T/S), which govern plant systems configurations and operations, are in conformance with the requirements of the Final Safety Analysis Report (FSAR) as amended, and the requirements of the Safety Evaluation Report (SER) as supplemented. A comparative audit of the FSAR as amended, and the SER as supplemented was performed with the River Bend T/S. Several discrepancies were identified and subsequently resolved through discussions with the cognizant NRC reviewer, NRC staff reviewers and/or utility representatives. The River Bend Station Unit 1 T/S, to the extent reviewed, are in conformance with the FSAR and SER

  7. Experience of the United States in Hosting and Supporting IAEA Peer Review Missions

    International Nuclear Information System (INIS)

    Mamish, N.

    2016-01-01

    The International Atomic Energy Agency (IAEA) provides a number of peer review services to its Member States. The United States has strongly supported these peer reviews since their inception. In 2010, the United States hosted an Integrated Regulatory Review Service (IRRS) mission, with a follow-up mission completed in 2014. The missions provided valuable recommendations and suggestions, identified a number of best practices, and acknowledged the prompt and effective actions taken by the NRC following the Fukushima Daiichi accident. Through hosting an International Physical Protection Advisory Service (IPPAS) mission in 2013, the United States benefited both from the insights provided by the team, as well as the U.S. Government’s gap analyses and preparatory efforts in advance of the mission. The United States strongly supports the IAEA’s Operational Safety Review Team (OSART) program, inviting a peer review mission to a U.S. nuclear power plant every 3 years. Although OSART is an operational, not regulatory, peer review, the NRC provides funding for the mission and gives inspection credit to operators that host them. The United States also contributes significant technical expertise to IAEA peer review missions hosted by other Member States. With the IRRS and IPPAS reaching their 10th and 20th anniversaries respectively, these programs have improved as they have matured. However, it remains critical for Member States to continue to support these programs, and provide feedback to the IAEA Secretariat on their effectiveness and areas where IAEA might enhance them. Doing so will ensure peer reviews remain an effective tool for strengthening nuclear safety and security worldwide. (author)

  8. Judicial Process, Grade Eight. Resource Unit (Unit V).

    Science.gov (United States)

    Minnesota Univ., Minneapolis. Project Social Studies Curriculum Center.

    This resource unit, developed by the University of Minnesota's Project Social Studies, introduces eighth graders to the judicial process. The unit was designed with two major purposes in mind. First, it helps pupils understand judicial decision-making, and second, it provides for the study of the rights guaranteed by the federal Constitution. Both…

  9. 77 FR 40606 - United Water; Notice of Declaration of Intention and Petition for Relief, and Soliciting Comments...

    Science.gov (United States)

    2012-07-10

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. DI12-8-000] United Water...: DI12-8-000. c. Date Filed: June 11, 2012. d. Applicant: United Water. e. Name of Project: Arlington... Contact: Jeffrey McDonald, PE, Project Director, Fuss & O'Neill, 146 Hartford Road, Manchester, CT 06040...

  10. Regulatory aspects of underground disposal of radioactive waste in the United Kingdom

    International Nuclear Information System (INIS)

    Hookway, B.R.

    1980-01-01

    Government policy towards radioactive waste management in the United Kingdom of Great Britain and Northern Ireland is based on the system of dose limitations laid down by ICRP as interpreted by the National Radiological Protection Board for use in the United Kingdom. The paper describes the legislative and administrative arrangements by which this policy is enforced, including the work of the principal inspectorates, the Nuclear Installations Inspectorate and the Radiochemical Inspectorate together with the latter's equivalents in Scotland and Northern Ireland. It is concluded that the present legislation, including that relating to planning and the setting up of public inquiries, is sufficiently all-embracing to ensure both strict control of the disposal of all the radioactive waste currently arising or which will arise in the future and a high degree of public involvement in the necessary decisions. (author)

  11. Comparison of Plastic Surgery Residency Training in United States and China.

    Science.gov (United States)

    Zheng, Jianmin; Zhang, Boheng; Yin, Yiqing; Fang, Taolin; Wei, Ning; Lineaweaver, William C; Zhang, Feng

    2015-12-01

    Residency training is internationally recognized as the only way for the physicians to be qualified to practice independently. China has instituted a new residency training program for the specialty of plastic surgery. Meanwhile, plastic surgery residency training programs in the United States are presently in a transition because of restricted work hours. The purpose of this study is to compare the current characteristics of plastic surgery residency training in 2 countries. Flow path, structure, curriculum, operative experience, research, and evaluation of training in 2 countries were measured. The number of required cases was compared quantitatively whereas other aspects were compared qualitatively. Plastic surgery residency training programs in 2 countries differ regarding specific characteristics. Requirements to become a plastic surgery resident in the United States are more rigorous. Ownership structure of the regulatory agency for residency training in 2 countries is diverse. Training duration in the United States is more flexible. Clinical and research training is more practical and the method of evaluation of residency training is more reasonable in the United States. The job opportunities after residency differ substantially between 2 countries. Not every resident has a chance to be an independent surgeon and would require much more training time in China than it does in the United States. Plastic surgery residency training programs in the United States and China have their unique characteristics. The training programs in the United States are more standardized. Both the United States and China may complement each other to create training programs that will ultimately provide high-quality care for all people.

  12. Regulating web content: the nexus of legislation and performance standards in the United Kingdom and Norway.

    Science.gov (United States)

    Giannoumis, G Anthony

    2014-01-01

    Despite different historical traditions, previous research demonstrates a convergence between regulatory approaches in the United Kingdom and Norway. To understand this convergence, this article examines how different policy traditions influence the legal obligations of performance standards regulating web content for use by persons with disabilities. While convergence has led to similar policy approaches, I argue that national policy traditions have an impact on how governments establish legal obligations for standards compliance. The analysis reveals that national policy traditions influenced antidiscrimination legislation and the capacity and authority of regulatory agencies, which impacted the diverging legal obligations of standards in the United Kingdom and Norway. The analysis further suggests that policy actors mediate the reciprocal influence between national policy traditions and regulatory convergence mechanisms. Copyright © 2014 John Wiley & Sons, Ltd.

  13. The FMEA Analysis for Fuel Handling System at Cernavoda Unit 2

    International Nuclear Information System (INIS)

    Park, Jin Hee; Kim, Tae Woon; Rhee, Bo Wook; Yoon, Chul; Kim, Hyeong Tae; Cho, In Gil; Kim, Seong Ho

    2006-01-01

    A Nuclear Safety Evaluation was performed by an independent assessor at the request of the regulatory authority CNCAN (Comisia Nationala pentru Controlul Activitatilor Nucleare. National Committee for Nuclear Activities Control in Romania) to provide an independent overview of all the nuclear safety aspects of Cernavoda Unit 2 under construction and an expert opinion whether the completed Cernavoda Unit-2 Nuclear Power Plant would satisfy current Western European nuclear safety objectives and practices. A report was produced (Cernavoda 2 Nuclear Safety Expert Project, 'Task 10 . Safety Evaluation Report', A.F.Parsons, NNC Limited, December 2001) and contains recommendations either mandatory or advisory. The FMEA study, one of the mandatory recommendations, is performing now for fuel handling system and radioactive waste handling system for Cernavoda unit 2 in Romania sponsored by KHNP. In this paper, only the FMEA study for fuel handling system is presented

  14. Steam generator replacement in Bruce A Unit 1 and Unit 2

    International Nuclear Information System (INIS)

    Hart, R.S.

    2007-01-01

    The Bruce A Generating Station consists of four 900 MW class CANDU units. The reactor and Primary Heat Transport System for each Unit are housed within a reinforced concrete reactor vault. A large duct running below the reactor vaults accommodates the shared fuel handling system, and connects the four reactor vaults to the vacuum building. The reactor vaults, fuelling system duct and the vacuum building constitute the station vacuum containment system. Bruce A Unit 2 was shut down in 1995 and Bruce A Units 1, 3 and 4 were shutdown in 1997. Bruce A Units 3 and 4 were returned to service in late 2003 and are currently operating. Units 1 and 2 remain out of service. Bruce Power is currently undertaking a major rehabilitation of Bruce A Unit 1 and Unit 2 that will extend the in-service tile of these units by at least 25 years. Replacement of the Steam Generators (eight in each unit) is required; this work was awarded to SNC-Lavalin Nuclear (SLN). The existing steam drums (which house the steam separation and drying equipment) will be retained. Unit 2 is scheduled to be synchronized with the grid in 2009, followed by Unit 1 in 2009. Each Bruce A unit has two steam generating assemblies, one located above and to each end of the reactor. Each steam generating assembly consists of a horizontal cylindrical steam drum and four vertical Steam Generators. The vertical Steam Generators connect to individual nozzles that are located on the underside of the Steam Drum (SD). The steam drums are located in concrete shielding structures (steam drum enclosures). The lower sections of the Steam Generators penetrate the top of the reactor vaults: the containment pressure boundary is established by bellows assemblies that connect between the reactor vault roof slab and the Steam Generators. Each Steam Generators is supported from he bottom by a trapeze that is suspended from the reactor vault top structure. The Steam Generator Replacement (SGR) methodology developed by SLN for Unit 1

  15. 78 FR 22347 - GPU Nuclear Inc., Three Mile Island Nuclear Power Station, Unit 2, Exemption From Certain...

    Science.gov (United States)

    2013-04-15

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-320; NRC-2013-0065] GPU Nuclear Inc., Three Mile Island Nuclear Power Station, Unit 2, Exemption From Certain Security Requirements AGENCY: Nuclear... and State Materials and Environmental Management Programs, U.S. Nuclear Regulatory Commission...

  16. Cooling tower performance improvements for a cycling PC-fired unit

    International Nuclear Information System (INIS)

    Keckritz, M.; Thelen, A.

    1997-01-01

    The inevitable deregulation of the electric utility industry has caused many electric utility companies to look closely at their existing assets and predict what role these units will play in the future. Reducing a unit's production cost is the best way to prepare for the deregulated market but this benefit often comes with an associated capital expenditure. Spending capital dollars today can pose a quandary for an investor-owned utility committed to maintaining low consumer rates. The dilemma is: How does a utility improve its competitiveness position today while ensuring that the shareholders are getting a fair return on their investment when any fuel savings are passed through to the consumer? Illinois Power (IP) has been aggressively looking to improve their current competitive position while facing the current regulatory challenges. Studies have been commissioned to identify the most attractive cost reduction opportunities available. One study identified that improving the performance of the Unit 6 cooling tower at the Havana Station would be a very economically attractive option. This paper addresses the economics of refurbishing a cooling tower for a cycling pulverized-coal (PC) unit to provide a competitive advantage leading into the deregulated electricity market

  17. 78 FR 49305 - Luminant Generation Company LLC, Comanche Peak Nuclear Power Plant, Unit Nos. 1 and 2...

    Science.gov (United States)

    2013-08-13

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-445 and 50-446; NRC-2013-0182] Luminant Generation Company LLC, Comanche Peak Nuclear Power Plant, Unit Nos. 1 and 2; Application for Amendment to Facility... Operating License Nos. NPF-87 and NPF-89 for the Comanche Peak Nuclear Power Plant, Unit Nos. 1 and 2...

  18. Environmental protection uranium recovery issues in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Peake, R.T.; Cherepy, A.; Rosnick, R.; Schultheisz, D.; Setlow, L. [U.S. Environmental Protection Agency, Washington, DC (United States)

    2011-07-01

    Uranium recovery activities in the United States were at a standstill just a few years ago. Demand for processed uranium yellowcake has increased, as has its price, though the price is down since the Fukushima reactor accident. Interest in producing uranium has increased, too. Currently the most preferred, low-cost uranium extraction method in the United States is in-situ leach (ISL) recovery where the geohydrology is conducive to injection, mobilization and pumping. A number of applications for new ISL and conventional mills have recently been submitted or are expected to be submitted for licensing by the Nuclear Regulatory Commission (NRC). In the United States, the Environmental Protection Agency (EPA) has developed Health and Environmental Protection Standards for Uranium and Thorium Mill Tailings under the authority of the Uranium Mill Tailings Radiation Control Act of 1978 (UMTRCA). These standards are found in the Code of Federal Regulations, Title 40, Part 192 (40 CFR Part 192). The NRC develops implementing regulations for 40 CFR Part 192 and then NRC or delegated States enforce the NRC and EPA regulations. Facilities regulated under 40 CFR Part 192 include conventional uranium and thorium mills as well as in-situ leach operations, which are considered to be 'milling underground' for regulatory purposes. However, there are no explicit standards for ISL operations in 40 CFR Part 192. In addition, EPA has determined that portions of the operations at uranium recovery operations, specifically the radon emissions from tailings impoundments, are covered by Section 112 of the Clean Air Act as a source of hazardous air pollutants (HAPs). EPA addresses these operations in 40 CFR Part 61, Subpart W. EPA is in the process of reviewing both 40 CFR Part 192 and 40 CFR Part 61, Subpart W for possible revision. This paper presents some of the issues related to uranium recovery that are being considered in the current regulatory review. (author)

  19. Experience with HEPA filters at United States nuclear installations

    International Nuclear Information System (INIS)

    Bellamy, R.R.

    1977-01-01

    Part 50 of Title 10 of the United States Code of Federal Regulations requires that a number of atmosphere cleanup systems be included in the design of commercial nuclear power plants to be licensed in the United States. These filtering systems are to contain high efficiency particulate air (HEPA) filters for removal of radioactive particulate matter generated during normal and accident conditions. Recommendations for the design, testing and maintenance of the filtering systems and HEPA filter components are contained in a number of United States Nuclear Regulatory Commission documents and industry standards. This paper will discuss this published guidance available to designers of filtering systems and the plant operators of U.S. commercial nuclear power plants. The paper will also present a survey of published reports of experience with HEPA filters, failures and possible causes for the failures, and other abnormal occurrences pertaining to HEPA filters installed in U.S. nuclear power installations. A discussion will be included of U.S. practices for qualification of HEPA filters before installation, and verification of continued performance capability at scheduled intervals during operation

  20. Control room habitability Analysis and Testing for Wolsong Unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. B. [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    In response to this recommendation, KHNP has established CRH program and performed tracer gas in leakage tests. These activities are described herein including the emergency ventilation system analysis, acceptance criteria calculation for the test and Control Room Envelope (CRE) discrimination, and the results of the tracer gas tests are presented. CRH analysis including unfiltered in leakage tests according to the methodology in ASTM E741 was performed for Wolsong Unit 1. The results show that the integrity of the control room of Wolsong Unit 1 is in good condition to maintain the reactor in a safe condition under accident conditions, which complies with the US NRC regulatory guides 1.78, 1.196 and 1.197.

  1. Detector Unit

    CERN Multimedia

    1960-01-01

    Original detector unit of the Instituut voor Kernfysisch Onderzoek (IKO) BOL project. This detector unit shows that silicon detectors for nuclear physics particle detection were already developed and in use in the 1960's in Amsterdam. Also the idea of putting 'strips' onto the silicon for high spatial resolution of a particle's impact on the detector were implemented in the BOL project which used 64 of these detector units. The IKO BOL project with its silicon particle detectors was designed, built and operated from 1965 to roughly 1977. Detector Unit of the BOL project: These detectors, notably the ‘checkerboard detector’, were developed during the years 1964-1968 in Amsterdam, The Netherlands, by the Natuurkundig Laboratorium of the N.V. Philips Gloeilampen Fabrieken. This was done in close collaboration with the Instituut voor Kernfysisch Onderzoek (IKO) where the read-out electronics for their use in the BOL Project was developed and produced.

  2. Historical Accumulation of Nonindigenous Forest Pests in the Continental United States

    Science.gov (United States)

    J.E. Aukema; D.G. McCullough; B.V. Holle; A.M. Liebhold; S.J. Frankel

    2010-01-01

    Nonindigenous forest insects and pathogens affect a range of ecosystems, industries, and property owners in the United States. Evaluating temporal patterns in the accumulation of these nonindigenous forest pests can inform regulatory and policy decisions. We compiled a comprehensive species list to assess the accumulation rates of nonindigenous forest insects and...

  3. Emergency planning requirements and short-term countermeasures for commercial nuclear power plants in the United States

    International Nuclear Information System (INIS)

    Kantor, F.; Hogan, R.; Mohseni, A.

    1995-01-01

    Since the accident at the Three Mile Island Unit, the United States Nuclear Regulatory's Commission (NRC's) emergency planning regulations are now considered and an important part of the regulatory framework for protecting the public health and safety. Many aspects of the countermeasures are presented: Emergency Planning Zones (EPZ), off-Site emergency planning and preparedness, responsibilities of nuclear power plants operators and states and local government. Finally, protective action recommendations are given as well as the federal response to an emergency. The authors noted that the use of potassium iodide is not considered as an effective countermeasure for the public protection in the US. (TEC). 1 fig

  4. 76 FR 72007 - ZionSolutions, LLC; Zion Nuclear Power Station, Units 1 and 2; Exemption From Certain Security...

    Science.gov (United States)

    2011-11-21

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-295 and 50-304; NRC-2011-0244] ZionSolutions, LLC; Zion Nuclear Power Station, Units 1 and 2; Exemption From Certain Security Requirements 1.0 Background Zion Nuclear Power Station (ZNPS or Zion), Unit 1, is a Westinghouse 3250 MWt Pressurized Water Reactor...

  5. 75 FR 43572 - Duke Energy Carolinas, LLC, McGuire Nuclear Station, Units 1 and 2; Environmental Assessment and...

    Science.gov (United States)

    2010-07-26

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-369 and 50-370; NRC-2010-0259] Duke Energy Carolinas, LLC, McGuire Nuclear Station, Units 1 and 2; Environmental Assessment and Finding of No Significant... Energy Carolinas, LLC (the licensee), for operation of the McGuire Nuclear Station, Units 1 and 2...

  6. Analysis of loss of decay heat removal sequences at Browns Ferry Unit One: Chapter 17

    International Nuclear Information System (INIS)

    Harrington, R.M.

    1983-01-01

    This paper summarizes the Oak Ridge National Laboratory (ORNL) report ''Loss of DHR Sequences at Browns Ferry Unit One - Accident Sequence Analysis'' (NUREG/CR-2973). The Loss of DHR investigation is the third in a series of accident studies concerning the BWR 4 - MK I containment plant design. These studies, sponsored by the Nuclear Regulatory Commission Severe Accident Sequence Analysis (SASA) program, have been conducted at ORNL with the full cooperation of the Tennessee Valley Authority (TVA), using Unit One of the Browns Ferry Nuclear Plant as the model design. Each unit of this three-unit plant has a maximum authorized power of 3293 MW(t) or 1067 net MW(e). The primary containments are of the Mark I pressure suppression pool type and the three units share a secondary containment of the controlled leakage, elevated release design. Each unit occupies a separate reactor building located in one structure underneath the common refueling floor

  7. Second unit scheduling concerns on a dual-unit nuclear project

    International Nuclear Information System (INIS)

    Block, H.R.; Mazzini, R.A.

    1978-01-01

    This paper explores the planning and scheduling problems of Unit 2 of the Susquehanna steam electric station. The causes of these problems and methods to avoid or mitigate their consequences are discussed. The Susquehanna steam electric station has two boiling water reactors rated at 1,100 MW each. Topics considered include cost factors, structures, equipment, engineering and home office, construction services, completion data phasing, work sequencing, structural dependences, and segregation. Substatial cost and schedule benefits can result if two nuclear units are designed and constructed as one integral station, and if maximum sharing of facilities and services between the units occurs. It is concluded that the cost benefits of highly integrated dual unit construction outweigh the schedule and logistical problems caused by that approach

  8. Risk analysis of NPP in multi-unit site for configuration of AAC power source

    International Nuclear Information System (INIS)

    Kim, Myung Ki

    2000-01-01

    Because of the difficulties in finding new sites for nuclear power plants, more units are being added to the existing sites. In these multi-unit sites, appropriate countermeasures should be established to cope with the potential station blackout (SBO) accident. Currently, installation of additional diesel generator (DG) is considered to ensure an alternative AC power source, but it has not been decided yet how many DGs should be installed in a multi-unit site. In this paper, risk informed decision making method, which evaluates reliability of electrical system, core damage frequency, and site average core damage frequency, is introduced to draw up the suitable number of DG in multi-unit site. The analysis results show that installing two DGs lowered the site average core damage frequency by 1.4% compared to one DG in six unit site. In the light of risk-informed decisions in regulatory guide 1.174, there is no difference of safety between two alternatives. It is concluded that one emergency diesel generator sufficiently guarantees safety against station blackout of nuclear power plants in multi-unit site. (author)

  9. Register of basic residential units and spatial units in the Slovak Republic

    International Nuclear Information System (INIS)

    Galdik, S.; Vavrinec, B.

    2005-01-01

    In this contribution authors deal with the register of basic residential units and spatial units in the Slovak Republic. Classification of statistical territorial units is presented. Map data and statistical data contain information about environmental impact of industrial and energetic mills

  10. Virginia Power's regulatory reduction program

    International Nuclear Information System (INIS)

    Miller, G.D.

    1996-01-01

    Virginia Power has two nuclear plants, North Anna and Surry Power Stations, which have two units each for a total of four nuclear units. In 1992, the Nuclear Regulatory Commission solicited comments from the nuclear industry to obtain their ideas for reducing the regulatory burden on nuclear facilities. Pursuant to the new regulatory climate, Virginia Power developed an internal program to evaluate and assess the regulatory and self-imposed requirements to which they were committed, and to pursue regulatory relief or internal changes where possible and appropriate. The criteria were that public safety must be maintained, and savings must be significant. Up to the date of the conference, over US$22 million of one-time saving had been effected, and US$2.75 million in annual savings

  11. SmartUnit: Empirical Evaluations for Automated Unit Testing of Embedded Software in Industry

    OpenAIRE

    Zhang, Chengyu; Yan, Yichen; Zhou, Hanru; Yao, Yinbo; Wu, Ke; Su, Ting; Miao, Weikai; Pu, Geguang

    2018-01-01

    In this paper, we aim at the automated unit coverage-based testing for embedded software. To achieve the goal, by analyzing the industrial requirements and our previous work on automated unit testing tool CAUT, we rebuild a new tool, SmartUnit, to solve the engineering requirements that take place in our partner companies. SmartUnit is a dynamic symbolic execution implementation, which supports statement, branch, boundary value and MC/DC coverage. SmartUnit has been used to test more than one...

  12. Licensing the first nuclear power plant in the United Arab Emirates

    International Nuclear Information System (INIS)

    Grant, I.

    2013-01-01

    United Arab Emirates (UAE) has established a comprehensive legal & regulatory framework conforming to IAEA standards/guidance to regulate the nuclear sector. Federal Authority for Nuclear Regulation (FANR) is a functioning independent nuclear regulator providing controls on safety, security and non-proliferation. UAE benefits from strong international support, incl. IAEA and access to Korean organizations and practices. UAE has an active capacity building programme both human and technical. Peer reviews show UAE regulatory system is aligned with good international practices. UAE has long term commitment to develop and maintain safety culture.

  13. 78 FR 77508 - Duke Energy Carolinas, LLC; William States Lee III Nuclear Station, Units 1 and 2; Combined...

    Science.gov (United States)

    2013-12-23

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 52-018 and 52-019; NRC-2008-0170] Duke Energy Carolinas, LLC; William States Lee III Nuclear Station, Units 1 and 2; Combined Licenses Application Review AGENCY: Nuclear Regulatory Commission. ACTION: Final environmental impact statement; availability...

  14. 76 FR 81994 - UniStar Nuclear Energy; Combined License Application for Calvert Cliffs Nuclear Power Plant, Unit...

    Science.gov (United States)

    2011-12-29

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 52-016; NRC-2008-0250] UniStar Nuclear Energy; Combined License Application for Calvert Cliffs Nuclear Power Plant, Unit 3; Exemption 1.0 Background: UniStar Nuclear Energy (UNE) submitted to the U.S. Nuclear Regulatory Commission (NRC or the Commission ) a...

  15. One-unit versus two-unit cord-blood transplantation for hematologic cancers.

    Science.gov (United States)

    Wagner, John E; Eapen, Mary; Carter, Shelly; Wang, Yanli; Schultz, Kirk R; Wall, Donna A; Bunin, Nancy; Delaney, Colleen; Haut, Paul; Margolis, David; Peres, Edward; Verneris, Michael R; Walters, Mark; Horowitz, Mary M; Kurtzberg, Joanne

    2014-10-30

    Umbilical-cord blood has been used as the source of hematopoietic stem cells in an estimated 30,000 transplants. The limited number of hematopoietic cells in a single cord-blood unit prevents its use in recipients with larger body mass and results in delayed hematopoietic recovery and higher mortality. Therefore, we hypothesized that the greater numbers of hematopoietic cells in two units of cord blood would be associated with improved outcomes after transplantation. Between December 1, 2006, and February 24, 2012, a total of 224 patients 1 to 21 years of age with hematologic cancer were randomly assigned to undergo double-unit (111 patients) or single-unit (113 patients) cord-blood transplantation after a uniform myeloablative conditioning regimen and immunoprophylaxis for graft-versus-host disease (GVHD). The primary end point was 1-year overall survival. Treatment groups were matched for age, sex, self-reported race (white vs. nonwhite), performance status, degree of donor-recipient HLA matching, and disease type and status at transplantation. The 1-year overall survival rate was 65% (95% confidence interval [CI], 56 to 74) and 73% (95% CI, 63 to 80) among recipients of double and single cord-blood units, respectively (P=0.17). Similar outcomes in the two groups were also observed with respect to the rates of disease-free survival, neutrophil recovery, transplantation-related death, relapse, infections, immunologic reconstitution, and grade II-IV acute GVHD. However, improved platelet recovery and lower incidences of grade III and IV acute and extensive chronic GVHD were observed among recipients of a single cord-blood unit. We found that among children and adolescents with hematologic cancer, survival rates were similar after single-unit and double-unit cord-blood transplantation; however, a single-unit cord-blood transplant was associated with better platelet recovery and a lower risk of GVHD. (Funded by the National Heart, Lung, and Blood Institute and the

  16. Public Discussion about Completion of Mochovce Units 3 and 4

    International Nuclear Information System (INIS)

    Anon

    2014-01-01

    After the introduction of the Nuclear Regulatory Authority (NRA) reopened NRA, the participants familiarised themselves with the history of M.I.5 (1980-2008), with the decisions of the NRA issued in 2008, with the law-suit and the judgement of the Supreme Court of the Slovak Republic, with the course of the procedure after the judgement, and with the comments, proposals and suggestions of the procedure participants delivered to the Authority within the specified period. The public hearing of the comments was followed by technical comments of the procedure participants focused on events at one unit that can affect the neighbouring unit, containment concept, seismic threat and accidents with fuel melting, which were fully answered by the competent persons. The hearing ended with a discussion.

  17. Evaluation of Watts Bar Nuclear Plant Unit 1 Technical Specifications

    International Nuclear Information System (INIS)

    Baxter, D.E.; Bruske, S.J.

    1985-08-01

    This document was prepared for the Nuclear Regulatory Commission (NRC) to assist them in determining whether the Watts Bar Nuclear Plant Unit 1 Technical Specifications (T/S), which govern plant systems configurations and operations, are in conformance with the assumption of the Final Safety Analysis Report (FSAR) as amended, and the requirements of the Safety Evaluation Report (SER) as supplemented. A comparative audit of the FSAR as amended, and the SER as supplemented was performed with the Watts Bar T/S. Several discrepancies were identified and subsequently resolved through discussions with the cognizant NRC reviewer, NRC staff reviewers and/or utility representatives. The Watts Bar Nuclear Plant Unit 1 T/S, to the extent reviewed, are in conformance with the FSAR and SER

  18. Evaluation of Shoreham Nuclear Power Station, Unit 1 technical specifications

    International Nuclear Information System (INIS)

    Baxter, D.E.; Bruske, S.J.

    1985-08-01

    This document was prepared for the Nuclear Regulatory Commission (NRC) to assist them in determining whether the Shoreham Nuclear Power Station Unit 1 Technical Specifications (T/S), which govern plant systems configurations and operations, are in conformance with the assumptions of the Final Safety Analysis Report (FSAR) as amended, and the requirements of the Safety Evaluation Report (SER) as supplemented. A comparative audit of the FSAR as amended, and the SER as supplemented was performed with the Shoreham T/S. Several discrepancies were identified and subsequently resolved through discussions with the cognizant NRC reviewer, NRC staff reviewers and/or utility representatives. The Shoreham Nuclear Power Station Unit 1 T/S, to the extent reviewed, are in conformance with the FSAR and SER

  19. Evaluation of Waterford Steam Electric Station Unit 3 technical specifications

    International Nuclear Information System (INIS)

    Baxter, D.E.; Bruske, S.J.

    1985-09-01

    This document was prepared for the Nuclear Regulatory Commission (NRC) to assist them in determining whether the Waterford Steam Electric Station Unit 3 Technical Specifications (T/S), which govern plant systems configurations and operations, are in conformance with the requirements of the Final Safety Analysis Report (FSAR) as amended, and the requirements of the Safety Evaluation Report (SER) as supplemented. A comparative audit of the FSAR as amended, and the SER as supplemented was performed with the Waterford T/S. Several discrepancies were identified and subsequently resolved by the cognizant NRC reviewer. Pending completion of the resolutions noted in Part 3 of this report, the Waterford Steam Electric Station Unit 3 T/S, to the extent reviewed, are in conformance with the FSAR and SER

  20. 77 FR 31290 - Notice of Public Meeting of the Assembly of the Administrative Conference of the United States

    Science.gov (United States)

    2012-05-25

    ... recommendations to administrative agencies, the President, Congress, and the Judicial Conference of the United... more effective public participation and efficiency in the rulemaking process, reduce unnecessary litigation in the regulatory process, improve the use of science in the regulatory process, and improve the...

  1. Challenges encountered by critical care unit managers in the large intensive care units.

    Science.gov (United States)

    Matlakala, Mokgadi C; Bezuidenhout, Martie C; Botha, Annali D H

    2014-04-04

    Nurses in intensive care units (ICUs) are exposed regularly to huge demands interms of fulfilling the many roles that are placed upon them. Unit managers, in particular, are responsible for the efficient management of the units and have the responsibilities of planning, organising, leading and controlling the daily activities in order to facilitate the achievement of the unit objectives. The objective of this study was to explore and present the challenges encountered by ICU managers in the management of large ICUs. A qualitative, exploratory and descriptive study was conducted at five hospital ICUs in Gauteng province, South Africa. Data were collected through individual interviews from purposively-selected critical care unit managers, then analysed using the matic coding. Five themes emerged from the data: challenges related to the layout and structure of the unit, human resources provision and staffing, provision of material resources, stressors in the unit and visitors in the ICU. Unit managers in large ICUs face multifaceted challenges which include the demand for efficient and sufficient specialised nurses; lack of or inadequate equipment that goes along with technology in ICU and supplies; and stressors in the ICU that limit the efficiency to plan, organise, lead and control the daily activities in the unit. The challenges identified call for multiple strategies to assist in the efficient management of large ICUs.

  2. Challenges encountered by critical care unit managers in the large intensive care units

    Directory of Open Access Journals (Sweden)

    Mokgadi C. Matlakala

    2014-04-01

    Full Text Available Background: Nurses in intensive care units (ICUs are exposed regularly to huge demands interms of fulfilling the many roles that are placed upon them. Unit managers, in particular, are responsible for the efficient management of the units and have the responsibilities of planning, organising, leading and controlling the daily activities in order to facilitate the achievement of the unit objectives. Objectives: The objective of this study was to explore and present the challenges encountered by ICU managers in the management of large ICUs. Method: A qualitative, exploratory and descriptive study was conducted at five hospital ICUs in Gauteng province, South Africa. Data were collected through individual interviews from purposively-selected critical care unit managers, then analysed using the matic coding. Results: Five themes emerged from the data: challenges related to the layout and structure of the unit, human resources provision and staffing, provision of material resources, stressors in the unit and visitors in the ICU. Conclusion: Unit managers in large ICUs face multifaceted challenges which include the demand for efficient and sufficient specialised nurses; lack of or inadequate equipment that goes along with technology in ICU and supplies; and stressors in the ICU that limit the efficiency to plan, organise, lead and control the daily activities in the unit. The challenges identified call for multiple strategies to assist in the efficient management of large ICUs.

  3. Food irradiation: outlook for commercialization in the United States

    International Nuclear Information System (INIS)

    Giddings, G.G.

    1985-01-01

    An account is presented of the long-term and near-term outlooks for food irradiation in the United States, with particular reference to US regulatory status and to the problems of securing public acceptance of the process. Actions taken by international organizations to consider and determine whether irradiated food is wholesome are summarized. A table is included showing dose levels for various food applications. Political and sociological aspects are discussed. (U.K.)

  4. The Executive Process, Grade Eight. Resource Unit (Unit III).

    Science.gov (United States)

    Minnesota Univ., Minneapolis. Project Social Studies Curriculum Center.

    This resource unit, developed by the University of Minnesota's Project Social Studies, introduces eighth graders to the executive process. The unit uses case studies of presidential decision making such as the decision to drop the atomic bomb on Hiroshima, the Cuba Bay of Pigs and quarantine decisions, and the Little Rock decision. A case study of…

  5. Guide to federal regulation of sales of imported electricity in Canada, Mexico and the United States

    International Nuclear Information System (INIS)

    2005-01-01

    This Guide to Federal Regulation of Sales of Imported Electricity in Canada, Mexico, and the United States promotes cross-border electricity trade. It provides information on federal regulation of cross-border electricity trade and is intended to be used together with a companion guide called the North American Regulation of International Electricity Trade which outlines regulations for the construction and operation of cross-border power lines and the permitting requirements for electricity exports and imports between Canada, Mexico and the United States. The guide outlines the basic elements of the general federal regulatory process that applies to a given North American cross-border electricity trade. It offers an improved understanding of the applicable country's federal regulatory regime. Different federal government agencies within each country may regulate different aspects of a particular cross-border electricity trade. This guide does not examine the requirements that may apply at the state or provincial government levels. Rather, it is a collaborative effort of the 3 national energy departments and energy regulators that support the Experts Group on Electricity Regulatory Issues, a specialized unit assembled by the North American Energy Working Group (NAEWG). It was noted that the energy policies and regulations of each nation can change periodically

  6. Access to the decision-making process: opportunities for public involvement in the facility decommissioning process of the United States Nuclear Regulatory Commission

    International Nuclear Information System (INIS)

    Cameron, F.X.

    1996-01-01

    This paper discusses recent initiatives taken by the United States Nuclear Regulatory Commission NRC) to effectively involve the public in decommissioning decisions. Initiatives discussed include the Commission's rulemaking to establish the radiological criteria for decommissioning, as well as public involvement methods that have been used on a site-by-site basis. As un example of public involvement, the NRC is currently in the process of developing generic rules on the radiological criteria for the decontamination and decommissioning of NRC-licensed sites. Not only was this proposed rule developed through an extensive and novel approach for public involvement, but it also establishes the basic provisions that will govern public involvement in future NRC decisions on the decommissioning of individual sites. The aim is to provide the public with timely information about all phases of the NRC staff to express concerns and make recommendations. Th NRC recognizes the value and the necessity of effective public involvement in its regulatory activities and has initiated a number of changes to its regulatory program to accomplish this. From the NRC's perspective, it is much easier and less costly to incorporate these mechanisms for public involvement into the regulatory program early in the process, rather than try to add them after considerable public controversy on an action has already been generated. The historical antecedents for initiatives mentioned, as well as 'lessons learned' from prior experience are also discussed. (author)

  7. 75 FR 65012 - Small Hydropower Development in the United States; Notice of Small/Low-Impact Hydropower Webinar

    Science.gov (United States)

    2010-10-21

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD09-9-000] Small Hydropower Development in the United States; Notice of Small/Low-Impact Hydropower Webinar October 13, 2010. The Federal Energy Regulatory Commission will host a Small/Low- Impact Hydropower Webinar on November 10, 2010, from...

  8. RCRA land unit closures at the Y-12 Plant, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Welch, S.H.; Kelly, B.A.; Delozier, M.F.P.; Manrod, W.E.

    1987-01-01

    Eight land-based hazardous waste management units at the Y-12 Plant are being closed under an integrated multi-year program. Closure plans for the units have been submitted and are in various stages of revision and regulatory review. These units will be closed by various combinations of methods, including liquid removal and treatment, sludge stabilization, contaminated sludge and/or soil removal, and capping. The closure of these sites will be funded by a new Department of Energy budget category, the Environmental Restoration Budget Category (ERBC), which is intended to provide greater flexibility in the response to closure and remedial activities. A major project, Closure and Post-Closure Activities (CAPCA), has been identified for ERBC funding to close and remediate the land units in accordance with RCRA requirements. Establishing the scope of this program has required the development of a detailed set of assumptions and a confirmation program for each assumption. Other significant activities in the CAPCA program include the development of risk assessments and the preparation of an integrated schedule

  9. United Cerebral Palsy

    Science.gov (United States)

    ... your local affiliate Find your local affiliate United Cerebral Palsy United Cerebral Palsy (UCP) is a trusted resource for individuals with Cerebral Palsy and other disabilities and their networks. Individuals with ...

  10. Safety Evaluation Report on Tennessee Valley Authority: Browns Ferry Nuclear Performance Plan: Browns Ferry Unit 2 restart

    International Nuclear Information System (INIS)

    1989-04-01

    This safety evaluation report (SER) on the information submitted by the Tennessee Valley Authority (TVA) in its Nuclear Performance Plan, through Revision 2, for the Browns Ferry Nuclear Power Station and in supporting documents has been prepared by the US Nuclear Regulatory Commission staff. The plan addresses the plant-specific concerns requiring resolution before startup of Unit 2. The staff will inspect implementation of those programs. Where systems are common to Units 1 and 2 or to Units 2 and 3, the staff safety evaluations of those systems are included herein. 3 refs

  11. 78 FR 14361 - In the Matter of Luminant Generation Company LLC, Comanche Peak Nuclear Power Plant, Units 1 and...

    Science.gov (United States)

    2013-03-05

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0310; Docket Nos. 50-445 and 50-446; License Nos. NPF-87 and NPF-89] In the Matter of Luminant Generation Company LLC, Comanche Peak Nuclear Power Plant, Units... Nuclear Power Plant, Units 1 and 2 (CPNPP), and its Independent Spent Fuel Storage Installation Facility...

  12. Design Modification of Kori Unit 1 for the Equipment Qualification

    International Nuclear Information System (INIS)

    Park, J. W.; Kim, M. Y.; Han, K. T.; Park, J. D.

    2007-01-01

    There has not been a strict regulatory requirements for the Equipment Qualification(EQ) in 1970's when Kori Unit 1 had begun the construction and the commercial operation. The Korean regulatory body requested the EQ on the various safety-related components, as a result of Periodic Safety Review. However, the EQ itself is impossible in some areas, due to the high pressure/temperature and flooding environment conditions from the pipe breaks. Design modification is being considered in the Auxiliary Building, the Intermediate Building, the Component Cooling Water Heat Exchanger Building and the Turbine Building, in order to mitigate the environmental conditions for the EQ

  13. A regulatory view of the seismic re-evaluation of existing nuclear power plants in the United Kingdom

    International Nuclear Information System (INIS)

    Inkester, J.E.; Bradford, P.M.

    1995-01-01

    The paper describes the background to the seismic re-evaluation of existing nuclear power plants in the United Kingdom. Nuclear installations in this country were not designed specifically to resist earthquakes until the nineteen-seventies, although older plants were robustly constructed. The seismic capability of these older installations is now being evaluated as part of the periodic safety reviews which nuclear licensees are required to carry out. The regulatory requirements which set the framework for these studies are explained and the approaches being adopted by the licensees for their assessment of the seismic capability of existing plants are outlined. The process of hazard appraisal is reported together with a general overview of UK seismicity. The paper then discusses the methodologies used to evaluate the response of plant to the hazard. Various other types of nuclear installation besides power plants are subject to licensing in the UK and the application of seismic evaluation to some of these is briefly described. Finally the paper provides some comments on future initiatives and possible areas of development. (author)

  14. Hanford Site Waste management units report

    International Nuclear Information System (INIS)

    1992-01-01

    This report summarizes the operable units in several areas of the Hanford Site Waste Facility. Each operable unit has several waste units (crib, ditch, pond, etc.). The operable units are summarized by describing each was unit. Some of the descriptions are unit name, unit type, waste category start data, site description, etc. The descriptions will vary for each waste unit in each operable unit and area of the Hanford Site

  15. Environmental impact of accident-free transportation of radioactive material in the United States

    International Nuclear Information System (INIS)

    Taylor, J.M.; Smith, D.R.; Luna, R.E.

    1978-01-01

    A recent study performed for the Nuclear Regulatory Commission (NRC) by Sandia Laboratories which considered transportation of radioactive materials in the United States suggests that a significant portion of the radiological impact results from accident-free transport. This paper explores the basis for that conclusion

  16. Nuclear Regulatory Commission issuances, March 1975

    International Nuclear Information System (INIS)

    1975-04-01

    Reactor licensing actions taken by the Nuclear Regulatory Commission, the Atomic Safety and Licensing Appeal Board and the Atomic Safety and Licensing Boards for March 1975 are presented. Action was included for the following reactors: Big Rock Point Nuclear Plant; West Valley Reprocessing Plant; Limerick Generating Station, Units 1 and 2; Midland Plants, Units 1 and 2; Wolf Creek Generating Station, Unit 1; Monticello Nuclear Generating Plant, Unit 1; Douglas Point Nuclear Generating Station, Units 1 and 2; Seabrook Station, Units 1 and 2; Vermont Yankee Nuclear Power Station; and WPPSS Hanford Units 1 and 4. (U.S.)

  17. Allocating multiple units

    DEFF Research Database (Denmark)

    Tranæs, Torben; Krishna, Kala

    2002-01-01

    This paper studies the allocation and rent distribution in multi-unit, combinatorial-bid auctions under complete information. We focus on the natural multi-unit analogue of the first-price auction, where buyers bid total payments, pay their bids, and where the seller allocates goods to maximize his...... auction, which is the multi unit analogue of a second-price auction. Furthermore, we characterize these equilibria when valuations take a number of different forms: diminishing marginal valuations, increasing average valuations, and marginal valuations with single turning points...

  18. Technical Specifications, Limerick Generating Station, Unit No. 2 (Docket No. 50-353)

    International Nuclear Information System (INIS)

    1989-08-01

    The Limerick, Unit 2, Technical Specifications were prepared by the US Nuclear Regulatory Commission to set the limits, operating conditions, and other requirements applicable to a nuclear reactor facility as set forth in Section 50.36 of 10 CFR Part 50 for the protection of the health and safety of the public

  19. Technical specifications, Limerick Generating Station, Unit No. 2 (Docket No. 50-353)

    International Nuclear Information System (INIS)

    1989-07-01

    The Limerick, Unit 2, Technical Specifications were prepared by the US Nuclear Regulatory Commission to set the limits, operating conditions, and other requirements applicable to a nuclear reactor facility as set forth in Section 50.36 of 10 CFR Part 50 for the protection of the health and safety of the public

  20. 78 FR 45575 - Duke Energy Carolinas, LLC; Oconee Nuclear Station Units 1, 2, and 3; Independent Spent Fuel...

    Science.gov (United States)

    2013-07-29

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos.: 72-1004, 72-40, 50-269, 50-270, 50-287; and NRC-2013- 0135] Duke Energy Carolinas, LLC; Oconee Nuclear Station Units 1, 2, and 3; Independent Spent Fuel Storage Installation AGENCY: Nuclear Regulatory Commission. ACTION: Exemption; issuance. SUMMARY: The NRC...

  1. Evaluation of Perry Nuclear Power Plant Unit 1 technical specifications

    International Nuclear Information System (INIS)

    Baxter, D.E.; Bruske, S.J.

    1985-11-01

    This document was prepared for the Nuclear Regulatory Commission (NRC) to assist them in determining whether the Perry Nuclear Power Plant Unit 1 Technical Specifications (T/S), which govern plant systems configurations and operations, are in conformance with the requirements of the Final Safety Analysis Report (FSAR) as amended, and the requirements of the Safety Evaluation Report (SER) as supplemented. A comparative audit of the FSAR as amended, and the SER as supplemented was performed with the Perry T/S. Several discrepancies were identified and subsequently resolved through telephone conversations with the staff reviewer and the utility representative. Pending completion of the resolutions noted in Parts 3 and 4 of this report, the Perry Nuclear Power Plant Unit 1 T/S, to the extent reviewed, are in conformance with the FSAR and SER

  2. SI units in engineering and technology

    CERN Document Server

    Qasim, S H

    2016-01-01

    SI Units in Engineering and Technology focuses on the use of the International System of Units-Systeme International d'Unités (SI). The publication first elaborates on the SI, derivation of important engineering units, and derived SI units in science and engineering. Discussions focus on applied mechanics in mechanical engineering, electrical and magnetic units, stress and pressure, work and energy, power and force, and magnitude of SI units. The text then examines SI units conversion tables and engineering data in SI units. Tables include details on the sectional properties of metals in SI units, physical properties of important molded plastics, important physical constants expressed in SI units, and temperature, area, volume, and mass conversion. Tables that show the mathematical constants, standard values expressed in SI units, and Tex count conversion are also presented. The publication is a dependable source of data for researchers interested in the use of the International System of Units-Systeme Inter...

  3. 76 FR 81929 - Small Hydropower Development in the United States; Notice of Small/Low-Impact Hydropower Webinar

    Science.gov (United States)

    2011-12-29

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD09-9-000] Small Hydropower Development in the United States; Notice of Small/Low-Impact Hydropower Webinar The Federal Energy Regulatory Commission will host a Small/Low- Impact Hydropower Webinar on January 25, 2012, from 12:00 noon to 1:30 p.m...

  4. 76 FR 30937 - Small Hydropower Development in the United States; Notice of Small/Low-Impact Hydropower Webinar

    Science.gov (United States)

    2011-05-27

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD09-9-000] Small Hydropower Development in the United States; Notice of Small/Low-Impact Hydropower Webinar The Federal Energy Regulatory Commission (FERC) will host a Small/ Low-Impact Hydropower Webinar on June 22, 2011, from 12 noon to 1 p.m...

  5. Controlling engineering project changes for multi-unit, multi-site standardized nuclear power plants

    International Nuclear Information System (INIS)

    Randall, E.; Boddeker, G.; McGugin, H.; Strother, E.; Waggoner, G.

    1978-01-01

    Multibillioin dollar multiple nuclear power plant projects have numerous potential sources of engineering changes. The majority of these are internally generated changes, client generated changes, and changes from construction, procurement, other engineering organizations, and regulatory organizations. For multiunit, multisite projects, the use of a standardized design is cost effective. Engineering changes can then be controlled for a single standardized design, and the unit or site unique changes can be treated as deviations. Once an effective change procedure is established for change control of the standardized design, the same procedures can be used for control of unit or site unique changes

  6. RCRA facility investigation report for the 200-PO-1 operable unit. Revision 1

    International Nuclear Information System (INIS)

    1997-05-01

    This Resource Conservation and Recovery Act (RCRA) Facility Investigation (RFI) report is prepared in support of the RFI/corrective measures study process for the 200-PO-1 Groundwater Operable Unit in the 200 East Area of the Hanford Site. This report summarizes existing information on this operable unit presented in the 200 East and PUREX Aggregate Area Management Study Reports, contaminant specific studies, available modeling data, and groundwater monitoring data summary reports. Existing contaminant data are screened against current regulatory limits to determine contaminants of potential concern (COPC). Each identified COPC is evaluated using well-specific and plume trend analyses

  7. Decision unit program

    International Nuclear Information System (INIS)

    Madjar, N.; Pastor, C.; Chambon, B.; Drain, D.; Giorni, A.; Dauchy, A.

    1981-01-01

    A decision unit has been built to simplify the electronic logic set-up in multi-detectors experiments. This unit, designed with fast memories used as decision making tables, replaces conventional logic modules. Nine inputs are provided for receiving the fast detector signals (charged particles, gammas, neutrons, ...). Fifteen independent outputs allow the identification of the choosen events among the 2 9 possible events. A CAMAC interface between the unit and the computer, or a manual control auxiliary module, is used to load, in the memory, the pattern of the choosen events [fr

  8. Proceedings of the specialists' meeting on regulatory inspection practices in nuclear power plants

    International Nuclear Information System (INIS)

    1977-01-01

    The sessions and contributions of this conference are dealing with: the general problems of regulatory inspection of nuclear power plants and overall national practices (in Canada, France, Germany, Italy, Spain, the United States), specific problems and practical experience of regulatory inspection during site study, evaluation, design, manufacturing and construction of nuclear plants (in Finland, Germany, Spain, Sweden, Great-Britain, United States), quality insurance issues, pressure component regulations, specific problems and practical experience of regulatory inspection during commissioning (in Spain, Sweden, Great-Britain and United States), specific problems and practical experience of regulatory inspection during operation (in Spain, Great-Britain, Unites States, Italy and Sweden), special aspects of regulatory inspection (notably public information issues in Sweden and in Great-Britain, inspection of nuclear fuel transportation in Spain, enforcement programme in the USA)

  9. A multiplicity logic unit

    International Nuclear Information System (INIS)

    Bialkowski, J.; Moszynski, M.; Zagorski, A.

    1981-01-01

    The logic diagram principle of operation and some details of the design of the multiplicity logic unit are presented. This unit was specially designed to fulfil the requirements of a multidetector arrangement for gamma-ray multiplicity measurements. The unit is equipped with 16 inputs controlled by a common coincidence gate. It delivers a linear output pulse with the height proportional to the multiplicity of coincidences and logic pulses corresponding to 0, 1, ... up to >= 5-fold coincidences. These last outputs are used to steer the routing unit working with the multichannel analyser. (orig.)

  10. UniTed

    OpenAIRE

    Harma, Eero

    2010-01-01

    UniTed on Teddy boy- tyylistä inspiroitunut kevät/kesä mallisto naisille.Mallistossa yhdistyy perinteinen teddy boy- vaatetus ja klassinen feminiinisyys, sekä menneisyys ja nykyisyys. Suunnittelun lähtökohtia olivat naisellisuus, tyylikkyys ja pyrkimys luoda nykyaikaista suunnittelua menneisyydestä lainaillen. United is a teddy boy- style inspired spring/summer collection for women. The collection combines traditional Teddy boy style with classical feminity and past with the present. The b...

  11. Hanford Site waste management units report

    International Nuclear Information System (INIS)

    1993-04-01

    The Hanford Site Waste Management Units Report was originated to provide information responsive to Section 3004(u) of the Hazardous and Solid Waste Amendments of the 1984. This report provides a comprehensive inventory of all types of waste management units at the Hanford Site, including a description of the units and the waste they contain. Waste management units in the report include: (1) Resource Conservation and Recovery Act of 1976 (RCRA) disposal units, (2) Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) disposal units, (3) unplanned releases, (4) inactive contaminated structures, (5) RCRA treatment, storage, and disposal (TSD) units, and (6) other storage areas. Because of the comprehensive nature of the units report, the list of units is more extensive than required by Section 3004(u) of Hazardous and Solid Waste Amendments of the 1984. In Sections 3.0 through 6.0 of this report, the four aggregate areas are subdivided into their operable units. The operable units are further divided into two parts: (1) those waste management units assigned to the operable unit that will be remediated as part of the Environmental Restoration Remedial Actions (ERRA) Program, and (2) those waste management units located within the operable unit boundaries but not assigned to the ERRA program. Only some operable unit sections contain the second part.Volume two contains Sections 4.0 through 6.0 and the following appendices: Appendix A -- acronyms and definition of terms; Appendix B -- unplanned releases that are not considered to be units; and Appendix C -- operable unit maps

  12. Kozloduy NPP units 1-4 significance for Bulgaria

    International Nuclear Information System (INIS)

    Georgiev, J.

    2003-01-01

    General data about nuclear power in Bulgaria is presented. The main topics covered are: estimated energy reserve; energy balance, new capacities, installed in 2002; information about the WWER-230 reactors operation; environmental impact and global warming; Bulgarian export and regional electricity demand; public opinion etc. The problem 'Long term safe operation vs forced early closure' is discussed. It is concluded that the decision on early closure of any unit should be made on economic grounds or failure to meet regulatory safety standards and must not be politically motivated

  13. Licensing of HTGRs in the United States

    International Nuclear Information System (INIS)

    Fisher, C.R.; Orvis, D.D.

    1981-01-01

    The licensing history of the high-temperature gas-cooled reactor (HTGR) in the United States is given historical perspective. The experience began with the licensing of the Peach Bottom Atomic Power Station and extends to the continuing experience at the Fort St. Vrain Nuclear Generating Station. Additional experience was obtained from the licensing reviews in the mid-1970s of the large HTGR plants that were to be built by Philadelphia Electric Company and Delmarva Power and Light. Also, information was provided by the licensing review of the General Atomic standard plant by the U.S. Nuclear Regulatory Commission (NRC) at about the same time. These experiences are summarized in terms of the principal design criteria that were required by the regulatory authority for each project. These criteria include specification of the design basis accidents that were postulated for the plant safety analysis. Several technical issues raised by the NRC during their review of the large HTGR are presented. (author)

  14. Licensing of HTGRs in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, C. R.; Orvis, D. D. [General Atomic Co., San Diego, CA (USA)

    1981-01-15

    The licensing history of the high-temperature gas-cooled reactor (HTGR) in the United States is given historical perspective. The experience began with the licensing of the Peach Bottom Atomic Power Station and extends to the continuing experience at the Fort St. Vrain Nuclear Generating Station. Additional experience was obtained from the licensing reviews in the mid-1970s of the large HTGR plants that were to be built by Philadelphia Electric Company and Delmarva Power and Light. Also, information was provided by the licensing review of the General Atomic standard plant by the U.S. Nuclear Regulatory Commission (NRC) at about the same time. These experiences are summarized in terms of the principal design criteria that were required by the regulatory authority for each project. These criteria include specification of the design basis accidents that were postulated for the plant safety analysis. Several technical issues raised by the NRC during their review of the large HTGR are presented.

  15. Hanford Site waste management units report

    International Nuclear Information System (INIS)

    1993-04-01

    The Hanford Site Waste Management Units Report was originated to provide information responsive to Section 3004(u) of the Hazardous and Solid Waste Amendments of the 1984. This report provides a comprehensive inventory of all types of waste management units at the Hanford Site, including a description of the units and the waste they contain. Waste management units in the report include: (1) Resource Conservation and Recovery Act of 1976 (RCRA) disposal units, (2) Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) disposal units, (3) unplanned releases, (4) inactive contaminated structures, (5) RCRA treatment, storage, and disposal (TSD) units, and (6) other storage areas. Because of the comprehensive nature of the units report, the list of units is more extensive than required by Section 3004(u) of Hazardous and Solid Waste Amendments of the 1984. In Sections 3.0 through 6.0 of this report, the four aggregate areas are subdivided into their operable units. The operable units are further divided into two parts: (1) those waste management units assigned to the operable unit that will be remediated as part of the Environmental Restoration Remedial Actions (ERRA) Program, and (2) those waste management units located within the operable unit boundaries but not assigned to the ERRA program. Only some operable unit sections contain the second part

  16. 75 FR 14206 - FPL Energy Point Beach, LLC; Point Beach Nuclear Plant, Units 1 and 2; Environmental Assessment...

    Science.gov (United States)

    2010-03-24

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-266 And 50-301; NRC-2010-0123 FPL Energy Point Beach, LLC; Point Beach Nuclear Plant, Units 1 and 2; Environmental Assessment and Finding of No Significant Impact The U.S. Nuclear Regulatory Commission (NRC) is considering issuance of an Exemption, pursuant to...

  17. SI units in radiation protection

    International Nuclear Information System (INIS)

    Jain, V.K.; Soman, S.D.

    1978-01-01

    International System of Units abbreviated as SI units has been adopted by most of the countries of the world. Following this development, the implementation of SI units has become mandatory with a transition period of about ten years. Some of the journals have already adopted the SI units and any material sent for publication to them must use only these. International Commission on Radiation Units and Measurement (ICRU) published letters in several journals including Physics in Medicine and Biology, Health Physics, British Journal of Radiology, etc. outlining the latest recommendations on SI units to elicit the reactions of scientists in the general field of radiological sciences. Reactions to the letters were numerous as can be seen in the correspondence columns of these journals for the last few years and ranged from great misgivings and apprehension to support and appreciation. SI units have also been the subject of editorial comments in several journals. On the basis of a survey of this literature, it may be said that there was general agreement on the long term advantage of SI units inspite of some practical difficulties in their use particularly in the initial stages. This report presents a review of SI units in radiological sciences with a view to familiarize the users with the new units in terms of the old. A time table for the gradual changeover to the SI units is also outlined. (auth.)

  18. SI units in biomedical dosimetry

    International Nuclear Information System (INIS)

    Liden, K.

    1975-01-01

    The International commission on radiation units and measurements (ICRU), during the period from 1953 to 1962 presented its definitions of the quantities absorbed dose, exposure, activity, and dose equivalent and the corresponding special units the rad, the roentgen, the curie, and the rem. At the same time an international practical system of units was developed, Le Systeme International d'Unites (SI). It was adopted by the 11th Conference Generale des Poids et Mesures (CGPM) in 1960 and is now officially introduced in almost all countries. The general implementation of the SI means difficulties for the future use of the special radiation units, because the numerical factors involved prevent their adoption as SI units. In view of this, and after having sampled the opinion in the radiological field, the ICRU prepared a Statement on Units in July, 1974 which was forwarded to the Comite International des Poids et Mesures (CIPM) and its Comite Consultatif des Unites (CCU) for consideration. As a result of this statement the CIPM has now proposed, that the 15rh CGPM adopt special names for two SI units, namely the becquerel, symbol Bq, for the unit of activity of radionuclides equal to the reciprocal second, s 1- , and the gray, symbol Gy, for the unit of absorbed dose equal to the joule per kilogram, J/kg. The 15th CGPM will consider this matter in May, 1975. (author)

  19. Economic Impacts of Non-Native Forest Insects in the Continental United States

    Science.gov (United States)

    Juliann E. Aukema; Brian. Leung; Kent Kovacs; Corey Chivers; Jeffrey Englin; Susan J. Frankel; Robert G. Haight; Thomas P. Holmes; Andrew M. Liebhold; Deborah G. McCullough; Betsy. Von Holle

    2011-01-01

    Reliable estimates of the impacts and costs of biological invasions are critical to developing credible management, trade and regulatory policies. Worldwide, forests and urban trees provide important ecosystem services as well as economic and social benefits, but are threatened by non-native insects. More than 450 non-native forest insects are established in the United...

  20. Cross Selling Implementation From Outpatient Unit to Radiology Unit in Semen Gresik Hospital

    OpenAIRE

    Rochmah, Thinni Nurul; Faradisa, Mutiara Ayu

    2013-01-01

    Thelow visitingnumberinhospital€™sunitarecloselyrelatedtomarketingactivities,includinginternal marketing which consistsof cross sellingfromother units.Thisstudy aims toanalyze crossselling implementation from Outpatient Unit to Radiology Unit in Semen Gresik Hospital. This study was a cross sectional analytic design. Samplewastakenbysimple random samplingwithsamplesize25respondents.Independentvariableswere marketing policy,employee commitment,perception, motivation,andreadiness ofcross sellin...

  1. Drilling unit

    Energy Technology Data Exchange (ETDEWEB)

    Umanchik, N P; Demin, A V; Khrustalev, N N; Linnik, G N; Lovchev, S V; Rozin, M M; Sidorov, R V; Sokolov, S I; Tsaregradskiy, Yu P

    1981-01-01

    A drilling unit is proposed which includes a hydraulic lifter, hydraulic multiple-cylinder pump with valve distribution and sectional drilling pump with separators of the working and flushing fluid. In order to reduce metal consumption and the overall dimensions of the drilling unit, the working cavity of each cylinder of the hydraulic multiple-cylinder pump is equipped with suction and injection valves and is hydraulically connected to the working cavity by one of the sections of the drilling pump.

  2. 7 CFR 1160.104 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true United States. 1160.104 Section 1160.104 Agriculture... Definitions § 1160.104 United States. United States means the 48 contiguous states in the continental United States and the District of Columbia, except that United States means the 50 states of the United States...

  3. Managing carbon regulatory risk in utility resource planning: Current practices in the Western United States

    International Nuclear Information System (INIS)

    Barbose, Galen; Wiser, Ryan; Phadke, Amol; Goldman, Charles

    2008-01-01

    Concerns about global climate change have substantially increased the likelihood that future policy will seek to minimize carbon dioxide emissions. As such, even today, electric utilities are making resource planning and investment decisions that consider the possible implications of these future carbon regulations. In this article, we examine the manner in which utilities assess the financial risks associated with future carbon regulations within their long-term resource plans. We base our analysis on a review of the most recent resource plans filed by 15 electric utilities in the Western United States. Virtually all of these utilities made some effort to quantitatively evaluate the potential cost of future carbon regulations when analyzing alternate supply- and demand-side resource options for meeting customer load. Even without federal climate regulation in the US, the prospect of that regulation is already having an impact on utility decision-making and resource choices. That said, the methods and assumptions used by utilities to analyze carbon regulatory risk, and the impact of that analysis on their choice of a particular resource strategy, vary considerably, revealing a number of opportunities for analytic improvement. Though our review focuses on a subset of US electric utilities, this work holds implications for all electric utilities and energy policymakers who are seeking to minimize the compliance costs associated with future carbon regulations

  4. IAEA Completes Nuclear Security Review Mission in United States

    International Nuclear Information System (INIS)

    2013-01-01

    Full text: A team of nuclear security experts led by the International Atomic Energy Agency (IAEA) today completed a mission to review nuclear security practices of civil nuclear facilities licensed by the United States Nuclear Regulatory Commission (NRC). Conducted at the U.S. Government's request, the two-week International Physical Protection Advisory Service (IPPAS) mission reviewed the United States' nuclear security-related legislative and regulatory framework. As part of this work, the IPPAS team, led by John O'Dacre of Canada and comprising nine experts from eight IAEA Member States, met with NRC officials and reviewed the physical protection systems at the Center for Neutron Research (NCNR) at the National Institute of Standards and Technology. The IPPAS team concluded that nuclear security within the U.S. civil nuclear sector is robust and sustainable and has been significantly enhanced in recent years. The team identified a number of good practices in the nation's nuclear security regime and at the NCNR. The IPPAS team also made a recommendation and some suggestions for the continuing improvement of nuclear security overall. The mission in the United States was the 60th IPPAS mission organized by the IAEA. 'Independent international peer reviews such as IAEA IPPAS missions are increasingly being recognized for their value as a key component for exchanges of views and advice on nuclear security measures', said Khammar Mrabit, Director of the IAEA Office of Nuclear Security. 'The good practices identified during this mission will contribute to the continuous improvements of nuclear security in other Member States'. The IPPAS team provided a draft report to the NRC and will submit a final report soon. Because it contains security-related information about a specific nuclear site, IPPAS reports are not made public. 'The IPPAS programme gives us a chance to learn from the experience and perspective of our international partners', said NRC Chairman Allison M

  5. Regulatory difficulties in a developing country

    International Nuclear Information System (INIS)

    Jacobs, W.R. Jr.

    1978-01-01

    The regulatory agency assigned the task of regulating the initial entry into the field of nuclear power generation by a developing country has a very difficult job. Based on the authors' experience during the start-up and initial operation of Ko-Ri Unit I, the first power reactor in the Republic of Korea, observations on regulatory difficulties and recommendations for improved regulatory effectiveness are offered. The problem areas can be loosely grouped into three general categories: (1) Lack of adequate technical knowledge which is the basis for all effective regulation; (2) Difficulties with understanding and utilization of the required regulatory documentation; (3) Failure to establish the proper regulatory environment. Examples are cited from actual experience during the Ko-Ri Unit I start-up to demonstrate the impact that regulatory activities can have on a plant construction and testing programme. The problems encountered are not unique to developing countries but also exist in the United States of America. Recommendations are offered which should be beneficial to either newly formed regulatory agencies or agencies wishing to improve their abilities and effectiveness. These include: (1) Additional training of regulatory inspectors in plant operations; (2) Additional experience gained by participation in regulatory activities in other countries; (3) Increased attention given to regulatory documents, especially plant technical specifications; (4) Establishment of formal lines of communication between the utility and the regulatory agency; (5) Clear definition of regulatory responsibilities to avoid areas of overlapping jurisdiction; (6) Active participation by the regulatory staff very early in the project. It is hoped that these and other recommendations offered will greatly improve regulatory effectiveness and at the same time demonstrate that when the decision is made to 'go nuclear', a strong commitment must be made to develop and support a technically

  6. 77 FR 59679 - Central Vermont Public Service Corporation (Millstone Power Station, Unit 3); Order Approving...

    Science.gov (United States)

    2012-09-28

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0044; Docket No. 50-423] Central Vermont Public Service Corporation (Millstone Power Station, Unit 3); Order Approving Application Regarding Corporate Restructuring and Conforming Amendment I Dominion Nuclear Connecticut, Inc. (DNC), Central Vermont Public Service...

  7. Second periodic safety review of Angra Nuclear Power Station, unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Carlos F.O.; Crepaldi, Roberto; Freire, Enio M., E-mail: ottoncf@tecnatom.com.br, E-mail: emfreire46@gmail.com, E-mail: robcrepaldi@hotmail.com [Tecnatom do Brasil Engenharia e Servicos Ltda, Rio de Janeiro, RJ (Brazil); Campello, Sergio A., E-mail: sacampe@eletronuclear.gov.br [Eletrobras Termonuclear S.A. (ELETRONUCLEAR), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This paper describes the second Periodic Safety Review (PSR2-A1) of Angra Nuclear Power Station, Unit 1, prepared by Eletrobras Eletronuclear S.A. and Tecnatom do Brasil Engenharia e Servicos Ltda., during Jul.2013-Aug.2014, covering the period of 2004-2013. The site, in Angra dos Reis-RJ, Brazil, comprises: Unit 1, (640 MWe, Westinghouse PWR, operating), Unit 2 (1300 MWe, KWU/Areva, operating) and Unit 3 (1405 MWe, KWU/Areva, construction). The PSR2-A1 attends the Standards 1.26-Safety in Operation of Nuclear Power Plants, Brazilian Nuclear Regulatory Commission (CNEN), and IAEA.SSG.25-Periodic Safety Review of Nuclear Power Plants. Within 18 months after each 10 years operation, the operating organization shall perform a plant safety review, to investigate the evolution consequences of safety code and standards, regarding: Plant design; structure, systems and components behavior; equipment qualification; plant ageing management; deterministic and probabilistic safety analysis; risk analysis; safety performance; operating experience; organization and administration; procedures; human factors; emergency planning; radiation protection and environmental radiological impacts. The Review included 6 Areas and 14 Safety Parameters, covered by 33 Evaluations.After document evaluations and discussions with plant staff, it was generated one General and 33 Specific Guide Procedures, 33 Specific and one Final Report, including: Description, Strengths, Deficiencies, Areas for Improvement and Conclusions. An Action Plan was prepared by Electronuclear for the recommendations. It was concluded that the Unit was operated within safety standards and will attend its designed operational lifetime, including possible life extensions. The Final Report was submitted to CNEN, as one requisite for renewal of the Unit Permanent Operation License. (author)

  8. Second periodic safety review of Angra Nuclear Power Station, unit 1

    International Nuclear Information System (INIS)

    Martins, Carlos F.O.; Crepaldi, Roberto; Freire, Enio M.; Campello, Sergio A.

    2015-01-01

    This paper describes the second Periodic Safety Review (PSR2-A1) of Angra Nuclear Power Station, Unit 1, prepared by Eletrobras Eletronuclear S.A. and Tecnatom do Brasil Engenharia e Servicos Ltda., during Jul.2013-Aug.2014, covering the period of 2004-2013. The site, in Angra dos Reis-RJ, Brazil, comprises: Unit 1, (640 MWe, Westinghouse PWR, operating), Unit 2 (1300 MWe, KWU/Areva, operating) and Unit 3 (1405 MWe, KWU/Areva, construction). The PSR2-A1 attends the Standards 1.26-Safety in Operation of Nuclear Power Plants, Brazilian Nuclear Regulatory Commission (CNEN), and IAEA.SSG.25-Periodic Safety Review of Nuclear Power Plants. Within 18 months after each 10 years operation, the operating organization shall perform a plant safety review, to investigate the evolution consequences of safety code and standards, regarding: Plant design; structure, systems and components behavior; equipment qualification; plant ageing management; deterministic and probabilistic safety analysis; risk analysis; safety performance; operating experience; organization and administration; procedures; human factors; emergency planning; radiation protection and environmental radiological impacts. The Review included 6 Areas and 14 Safety Parameters, covered by 33 Evaluations.After document evaluations and discussions with plant staff, it was generated one General and 33 Specific Guide Procedures, 33 Specific and one Final Report, including: Description, Strengths, Deficiencies, Areas for Improvement and Conclusions. An Action Plan was prepared by Electronuclear for the recommendations. It was concluded that the Unit was operated within safety standards and will attend its designed operational lifetime, including possible life extensions. The Final Report was submitted to CNEN, as one requisite for renewal of the Unit Permanent Operation License. (author)

  9. Newman Unit 1 advanced solar repowering advanced conceptual design. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-04-01

    The Newman Unit 1 solar repowering design is a water/steam central receiver concept supplying superheated steam. The work reported is to develop a refined baseline conceptual design that has potential for construction and operation by 1986, makes use of existing solar thermal technology, and provides the best economics for this application. Trade studies performed in the design effort are described, both for the conceptual design of the overall system and for the subsystem conceptual design. System-level functional requirements, design, operation, performance, cost, safety, environmental, institutional, and regulatory considerations are described. Subsystems described include the collector, receiver, fossil energy, electrical power generating, and master control subsystems, site and site facilities. The conceptual design, cost, and performance of each subsystem is discussed at length. A detailed economic analysis of the repowered unit is made to realistically assess the economics of the first repowered unit using present cost data for a limited production level for solar hardware. Finally, a development plan is given, including the design, procurement, construction, checkout, startup, performance validation, and commercial operation. (LEW)

  10. Low-level radioactive waste disposal in the United States

    International Nuclear Information System (INIS)

    Ozaki, Calvin B.; Kerr, Thomas A.; Williams, R. Eric

    1991-01-01

    Two national systems comprise the low-level radioactive waste management system in the United States of America. The U.S. Nuclear Regulatory Commission regulates low-level radioactive waste produced in the public sector (commercial waste), and the U.S. Department of Energy manages low-level radioactive waste produced by government-sponsored programs. The primary distinction between the two national systems is the source of regulatory control. This paper discusses two issues critical to the success of each system: the site selection process used by the commercial low-level waste disposal system, and the evaluation process used to determine configuration of the DOE waste management system. The two national systems take different approaches to reach the same goals, which are increased social responsibility, protection of public health and safety, and protection of the environment

  11. Protective mechanical ventilation in United Kingdom critical care units: A multicentre audit.

    Science.gov (United States)

    Newell, Christopher P; Martin, Matthew J; Richardson, Neil; Bourdeaux, Christopher P

    2017-05-01

    Lung protective ventilation is becoming increasingly used for all critically ill patients being mechanically ventilated on a mandatory ventilator mode. Compliance with the universal application of this ventilation strategy in intensive care units in the United Kingdom is unknown. This 24-h audit of ventilation practice took place in 16 intensive care units in two regions of the United Kingdom. The mean tidal volume for all patients being ventilated on a mandatory ventilator mode was 7.2(±1.4) ml kg -1 predicted body weight and overall compliance with low tidal volume ventilation (≤6.5 ml kg -1 predicted body weight) was 34%. The mean tidal volume for patients ventilated with volume-controlled ventilation was 7.0(±1.2) ml kg -1 predicted body weight and 7.9(±1.8) ml kg -1 predicted body weight for pressure-controlled ventilation ( P  < 0.0001). Overall compliance with recommended levels of positive end-expiratory pressure was 72%. Significant variation in practice existed both at a regional and individual unit level.

  12. Nuclear Electricity in the United States : Providing Energy For The Nation's Security and Well-Being

    International Nuclear Information System (INIS)

    Finger, Harold B.

    1988-01-01

    Nuclear energy in the United States has made major contributions since the small Shippingport prototype power plant began operating in 1957. Recent legislative and regulatory actions, as well as research an development, are indicating that additional nuclear capacity can be available in the years ahead. These actions reflect the public's recognition of the importance of nuclear energy. In addition, recent regulatory actions are reaffirming the health and safety of our current nuclear plants, as well as of those being completed. The performance of our current plants is being improved through the conscious dedication of the entire industry to excellence. There is increasing discussion in the United States of the importance of advanced reactor concepts development. The next generation of nuclear plants is already being ordered outside of the United States for example, here in Korea, in Japan, in the United Kingdom and those plants all use light water reactors. We are pleased that U. S. companies are working with you on these new plants. That continues to mean that we never let up on our drive for excellence. Excellence in operations must continue to be the conscious target of all operators. Excellence in communications to the public of the need for electrical capacity, of the benefits of nuclear energy, and of the excellence being achieved in operations is also essential. And excellence in communication to decision makers at all levels of government is also required to assure that sound legalisation and regulation is established and implemented

  13. National legislative and regulatory activities

    International Nuclear Information System (INIS)

    2014-01-01

    This section of the Bulletin presents a summary of the recent national legislative and regulatory activities sorted by country and topic: - Algeria: Nuclear security. - France: Radioactive waste management; Nuclear safety and radiological protection; General legislation; International co-operation. - Germany: International trade. - Indonesia: Nuclear security, General legislation. - Ireland: Nuclear safety and radiological protection; General legislation. - Lithuania: Nuclear security; Nuclear safety and radiological protection. - Slovak Republic: International co-operation; Liability and compensation; Environmental protection. - Switzerland: Radioactive waste management. - United Arab Emirates: Liability and compensation. - United States: Radioactive waste management; Licensing and regulatory infrastructure

  14. Analysis of Serbian Military Riverine Units Capability for Participation in the United Nations Peacekeeping Operations

    Directory of Open Access Journals (Sweden)

    Slobodan Radojevic

    2017-06-01

    Full Text Available This paper analyses required personnel, training capacities and equipment for participation in the United Nations peacekeeping operations with the riverine elements. In order to meet necessary capabilities for engagement in United Nations peacekeeping operations, Serbian military riverine units have to be compatible with the issued UN requirements. Serbian Armed Forces have the potential to reach such requirements with the River Flotilla as a pivot for the participation in UN missions. Serbian Military Academy adopted and developed educational and training program in accordance with the provisions and recommendations of the IMO conventions and IMO model courses. Serbian Military Academy has opportunities for education and training military riverine units for participation in the United Nations peacekeeping operations. Moreover, Serbia has Multinational Operations Training Center and Peacekeeping Operations Center certified to provide selection, training, equipping and preparations of individuals and units to the United Nations multinational operations.

  15. Insight from Fukushima Daiichi Unit 3 Investigations using MELCOR

    International Nuclear Information System (INIS)

    Robb, Kevin R.; Francis, Matthew W.; Ott, Larry J.

    2014-01-01

    During the emergency response period of the accidents that took place at Fukushima Daiichi in March of 2011, researchers at Oak Ridge National Laboratory (ORNL) conducted a number of studies using the MELCOR code to help understand what was occurring and what had occurred. During the post-accident period, the Department of Energy (DOE) and the US Nuclear Regulatory Commission (NRC) jointly sponsored a study of the Fukushima Daiichi accident with collaboration among Oak Ridge, Sandia, and Idaho national laboratories. The purpose of the study was to compile relevant data, reconstruct the accident progression using computer codes, assess the codes predictive capabilities, and identify future data needs. The current paper summarizes some of the early MELCOR simulations and analyses conducted at ORNL of the Fukushima Daiichi Unit 3 accident. Extended analysis and discussion of the Unit 3 accident is also presented taking into account new knowledge and modeling refinements made since the joint DOE/NRC study

  16. Analysis of risk reduction measures applied to shared essential service water systems at multi-unit sites

    International Nuclear Information System (INIS)

    Kohut, P.; Musicki, Z.; Fitzpatrick, R.

    1991-06-01

    This report summarizes a study performed by Brookhaven National Laboratory for the US Nuclear Regulatory Commission in support of the resolution of NRC Generic Issue 130. GI-130 is concerned with the potential core damage vulnerability resulting from failure of the emergency service water (ESW) system in selected multiplant units. These multiplant units are all twin pressurized water reactor designs that have only two ESW pumps per unit (one per train) backed up by a unit crosstie capability. This generic issue applies to seven US sites (14 plants). The study established and analyzed the core damage vulnerability and identified potential improvements for the ESW system. It obtained generic estimates of the risk reduction potential and cost effectiveness of each potential improvement. The analysis also investigated the cost/benefit aspects of selected combinations of potential improvements. 4 figs., 62 tabs

  17. Integrating concerns about wood production and sustainable forest management in the United States.

    Science.gov (United States)

    R.W. Haynes

    2007-01-01

    The implementation of Sustainable Forest Management (SFM) in the United States is strongly influenced by U.S. forest products markets and the numerous management decisions made by individual landowners and managers. These decisions are influenced by a mix of market incentives and regulatory actions reducing predictability in assessing progress towards SFM and causing...

  18. Patient stress in intensive care: comparison between a coronary care unit and a general postoperative unit

    Science.gov (United States)

    Dias, Douglas de Sá; Resende, Mariane Vanessa; Diniz, Gisele do Carmo Leite Machado

    2015-01-01

    Objective To evaluate and compare stressors identified by patients of a coronary intensive care unit with those perceived by patients of a general postoperative intensive care unit. Methods This cross-sectional and descriptive study was conducted in the coronary intensive care and general postoperative intensive care units of a private hospital. In total, 60 patients participated in the study, 30 in each intensive care unit. The stressor scale was used in the intensive care units to identify the stressors. The mean score of each item of the scale was calculated followed by the total stress score. The differences between groups were considered significant when p < 0.05. Results The mean ages of patients were 55.63 ± 13.58 years in the coronary intensive care unit and 53.60 ± 17.47 years in the general postoperative intensive care unit. For patients in the coronary intensive care unit, the main stressors were “being in pain”, “being unable to fulfill family roles” and “being bored”. For patients in the general postoperative intensive care unit, the main stressors were “being in pain”, “being unable to fulfill family roles” and “not being able to communicate”. The mean total stress scores were 104.20 ± 30.95 in the coronary intensive care unit and 116.66 ± 23.72 (p = 0.085) in the general postoperative intensive care unit. When each stressor was compared separately, significant differences were noted only between three items. “Having nurses constantly doing things around your bed” was more stressful to the patients in the general postoperative intensive care unit than to those in the coronary intensive care unit (p = 0.013). Conversely, “hearing unfamiliar sounds and noises” and “hearing people talk about you” were the most stressful items for the patients in the coronary intensive care unit (p = 0.046 and 0.005, respectively). Conclusion The perception of major stressors and the total stress score were similar between patients

  19. METRIC context unit architecture

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, R.O.

    1988-01-01

    METRIC is an architecture for a simple but powerful Reduced Instruction Set Computer (RISC). Its speed comes from the simultaneous processing of several instruction streams, with instructions from the various streams being dispatched into METRIC's execution pipeline as they become available for execution. The pipeline is thus kept full, with a mix of instructions for several contexts in execution at the same time. True parallel programming is supported within a single execution unit, the METRIC Context Unit. METRIC's architecture provides for expansion through the addition of multiple Context Units and of specialized Functional Units. The architecture thus spans a range of size and performance from a single-chip microcomputer up through large and powerful multiprocessors. This research concentrates on the specification of the METRIC Context Unit at the architectural level. Performance tradeoffs made during METRIC's design are discussed, and projections of METRIC's performance are made based on simulation studies.

  20. Closure Plan for Corrective Action Unit 110: Area 3 RWMS U-3ax/bl Disposal Unit, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    Fitzmaurice, T. M.

    2000-01-01

    This Closure Plan has been prepared for the Area 3 RWMS U-3ax/bl Disposal Unit Corrective Action Unit 110 in accordance with the Federal Facility and Consent Order (Nevada Division of Environmental Protection [NDEP] et al., 1996). The U-3ax/bl is a historic disposal unit within the Area 3 Radioactive Waste Management Site located on the Nevada Test Site (NTS). The unit, which was formed by excavating the area between two subsidence craters (U-3ax and U-3bl), was operationally closed in 1987. The U-3ax/bl disposal unit is scheduled for permanent closure under the Resource Conservation and Recovery Act as a hazardous waste landfill. Existing records indicate that, from July 1968 to December 1987, U-3ax/bl received 2.3 x 10 5 cubic meters (8.12 x 10 6 cubic feet) of waste. NTS nuclear device testing generated approximately 95 percent of the total volume disposed of in U-3ax/bl, the majority of which came from the Waste Consolidation Project (80 percent of the total volume) (Elletson and Johnejack, 1995). Area 3 is located in Yucca Flat, within the northeast quadrant of the NTS. The Yucca Flat watershed is a structurally closed basin encompassing an area of approximately 780 square kilometers (300 square miles). The structural geomorphology of Yucca Flat is typical of the Basin and Range Physiographic Province. Yucca Flat lies in one of the most arid regions of the country. Water balance calculations for Area 3 indicate that it is continuously in a state of moisture deficit. The U-3ax/bl Disposal Unit will be closed in place by installing a Resource Conservation and Recovery Act equivalent cover. Following cover construction a fence will be installed around the cover to prevent accidental damage to the cover. Post-closure monitoring will consist of site inspections to determine the condition of the engineered cover and cover performance monitoring using Time-Domain Reflectometry arrays to monitor moisture migration in the cover. Any identified maintenance and repair

  1. Closure Plan for Corrective Action Unit 110: Area 3 RWMS U-3ax/bl Disposal Unit, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    T. M. Fitzmaurice

    2000-08-01

    This Closure Plan has been prepared for the Area 3 RWMS U-3ax/bl Disposal Unit Corrective Action Unit 110 in accordance with the Federal Facility and Consent Order (Nevada Division of Environmental Protection [NDEP] et al., 1996). The U-3ax/bl is a historic disposal unit within the Area 3 Radioactive Waste Management Site located on the Nevada Test Site (NTS). The unit, which was formed by excavating the area between two subsidence craters (U-3ax and U-3bl), was operationally closed in 1987. The U-3ax/bl disposal unit is scheduled for permanent closure under the Resource Conservation and Recovery Act as a hazardous waste landfill. Existing records indicate that, from July 1968 to December 1987, U-3ax/bl received 2.3 x 10{sup 5} cubic meters (8.12 x 10{sup 6} cubic feet) of waste. NTS nuclear device testing generated approximately 95 percent of the total volume disposed of in U-3ax/bl, the majority of which came from the Waste Consolidation Project (80 percent of the total volume) (Elletson and Johnejack, 1995). Area 3 is located in Yucca Flat, within the northeast quadrant of the NTS. The Yucca Flat watershed is a structurally closed basin encompassing an area of approximately 780 square kilometers (300 square miles). The structural geomorphology of Yucca Flat is typical of the Basin and Range Physiographic Province. Yucca Flat lies in one of the most arid regions of the country. Water balance calculations for Area 3 indicate that it is continuously in a state of moisture deficit. The U-3ax/bl Disposal Unit will be closed in place by installing a Resource Conservation and Recovery Act equivalent cover. Following cover construction a fence will be installed around the cover to prevent accidental damage to the cover. Post-closure monitoring will consist of site inspections to determine the condition of the engineered cover and cover performance monitoring using Time-Domain Reflectometry arrays to monitor moisture migration in the cover. Any identified maintenance and

  2. Hanford Site Waste Managements Units reports

    International Nuclear Information System (INIS)

    1992-01-01

    The Hanford Site Waste Management Units Report (HSWMUR) was originated to provide information responsive to Section 3004(u) of the Hazardous and Solid Waste Amendments (HSWA) of the 1984 United States Code (USC 1984). This report provides a comprehensive inventory of all types of waste management units at the Hanford Site, including a description of the units and the waste they contain. Waste management units in this report include: (1) Resource Conservation and Recovery Act of 1976 (RCRA) disposal units, (2) Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) disposal units, (3) unplanned releases, (4) inactive contaminated structures, (5) RCRA treatment, storage, and disposal (TSD) units, and (6) other storage areas. Because of the comprehensive nature of this report, the listing of sites is more extensive than required by Section 3004(u) of HSWA. The information in this report is extracted from the Waste Information Data System (WIDS). The WIDS provides additional information concerning the waste management units contained in this report and is maintained current with changes to these units. This report is updated annually if determined necessary per the Hanford Federal Facility Agreement and Consent Order Order (commonly referred to as the Tri-Party Agreement, Ecology et al. 1990). This report identifies 1,414 waste management units. Of these, 1,015 units are identified as solid waste management units (SWMU), and 342 are RCRA treatment, storage, and disposal units. The remaining 399 are comprised mainly of one-time spills to the environment, sanitary waste disposal facilities (i.e., septic tanks), and surplus facilities awaiting decontamination and decommissioning

  3. 3 CFR - Waiver of Reimbursement Under the United Nations Participation Act to Support the United Nations...

    Science.gov (United States)

    2010-01-01

    ... Participation Act to Support the United Nations/African Union Mission in Darfur Presidential Documents Other... the United Nations Participation Act to Support the United Nations/African Union Mission in Darfur... the United Nations/African Union Mission in Darfur to support the airlift of equipment for...

  4. Gas-centrifuge unit

    International Nuclear Information System (INIS)

    Stark, T.M.

    1977-01-01

    An isotope-enrichment unit is described for separating a gaseous mixture feedstock including a compound of a light nuclear isotope at a predetermined concentration and a compound of a heavy nuclear isotope at a predetermined concentration into at least two unit-output fractions including a waste fraction depleted in the light isotope to a predetermined concentration and a product fraction enriched in the light isotope to a predetermined concentration. The unit comprises a first group of cascades of gas centrifuges, each cascade having an enriching stage, a stripping stage, an input, a light-fraction output, and a heavy-fraction output for separating the gaseous-mixture feed stock into light and heavy gaseous-mixture fractions; and an auxillary cascade

  5. Deliberating the risks of nanotechnologies for energy and health applications in the United States and United Kingdom

    Science.gov (United States)

    Pidgeon, Nick; Harthorn, Barbara Herr; Bryant, Karl; Rogers-Hayden, Tee

    2009-02-01

    Emerging nanotechnologies pose a new set of challenges for researchers, governments, industries and citizen organizations that aim to develop effective modes of deliberation and risk communication early in the research and development process. These challenges derive from a number of issues including the wide range of materials and devices covered by the term `nanotechnology', the many different industrial sectors involved, the fact that many areas of nanotechnology are still at a relatively early stage of development, and uncertainty about the environmental, health and safety impacts of nanomaterials. Public surveys have found that people in the United States and Europe currently view the benefits of nanotechnologies as outweighing their risks although, overall, knowledge about nanotechnology remains very low. However, surveys cannot easily uncover the ways that people will interpret and understand the complexities of nanotechnologies (or any other topic about which they know very little) when asked to deliberate about it in more depth, so new approaches to engaging the public are needed. Here, we report the results of the first comparative United States-United Kingdom public engagement experiment. Based upon four concurrent half-day workshops debating energy and health nanotechnologies we find commonalities that were unexpected given the different risk regulatory histories in the two countries. Participants focused on benefits rather than risks and, in general, had a high regard for science and technology. Application context was much more salient than nation as a source of difference, with energy applications viewed in a substantially more positive light than applications in health and human enhancement in both countries. More subtle differences were present in views about the equitable distribution of benefits, corporate and governmental trustworthiness, the risks to realizing benefits, and in consumerist attitudes.

  6. 75 FR 52378 - International Product Change-United States Postal Service Inbound Market-Dominant Multi-Service...

    Science.gov (United States)

    2010-08-25

    ... POSTAL SERVICE International Product Change--United States Postal Service Inbound Market-Dominant... Inbound Market-Dominant Multi- Service Agreements to the Market-Dominant Products List pursuant to 39 U.S... the Postal Regulatory Commission to Add Market-Dominant Multi-Service Agreements with Foreign Postal...

  7. 31 CFR 800.225 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 800.225 Section 800... TAKEOVERS BY FOREIGN PERSONS Definitions § 800.225 United States. The term United States or U.S. means the United States of America, the States of the United States, the District of Columbia, and any commonwealth...

  8. Regulatory approaches to obesity prevention: A systematic overview of current laws addressing diet-related risk factors in the European Union and the United States.

    Science.gov (United States)

    Sisnowski, Jana; Handsley, Elizabeth; Street, Jackie M

    2015-06-01

    High prevalence of overweight and obesity remains a significant international public health problem. Law has been identified as a tool for obesity prevention and selected high-profile measures have been reported. However, the nature and extent of enacted legislation internationally are unclear. This research provides an overview of regulatory approaches enacted in the United States, the European Union, and EU Member States since 2004. To this end, relevant databases of primary and secondary legislation were systematically searched to identify and explore laws addressing dietary risk factors for obesity. Across jurisdictions, current regulatory approaches to obesity prevention are limited in reach and scope. Target groups are rarely the general population, but instead sub-populations in government-supported settings. Consumer information provision is preferred over taxation and marketing restrictions other than the regulation of health and nutrition claims. In the EU in particular, product reformulation with industry consent has also emerged as a popular small-scale measure. While consistent and widespread use of law is lacking, governments have employed a range of regulatory measures in the name of obesity prevention, indicating that there is, in principle, political will. Results from this study may serve as a starting point for future research and policy development. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. SI units in radiation protection

    International Nuclear Information System (INIS)

    Herrmann, D.

    1976-10-01

    In the field of radiation protection all hitherto used units for activity, activity concentrations, exposure, absorbed dose, and dose rates have to be replaced by SI units during the next years. For this purpose graphs and conversion tables are given as well as recommendations on unit combinations preferentially to be used. As to the dose equivalent, it is suggested to introduce a new special unit being 100 times greater than the rem, instead of maintaining the rem or using the gray for both absorbed dose and dose equivalent. Measures and time schedule relating to the gradual transition to SI units in measuring techniques, training, and publishing et cetera are explained. (author)

  10. Malaria Treatment (United States)

    Science.gov (United States)

    ... Providers, Emergency Consultations, and General Public. Contact Us Malaria Treatment (United States) Recommend on Facebook Tweet Share Compartir Treatment of Malaria: Guidelines For Clinicians (United States) Download PDF version ...

  11. Matching soil grid unit resolutions with polygon unit scales for DNDC modelling of regional SOC pool

    Science.gov (United States)

    Zhang, H. D.; Yu, D. S.; Ni, Y. L.; Zhang, L. M.; Shi, X. Z.

    2015-03-01

    Matching soil grid unit resolution with polygon unit map scale is important to minimize uncertainty of regional soil organic carbon (SOC) pool simulation as their strong influences on the uncertainty. A series of soil grid units at varying cell sizes were derived from soil polygon units at the six map scales of 1:50 000 (C5), 1:200 000 (D2), 1:500 000 (P5), 1:1 000 000 (N1), 1:4 000 000 (N4) and 1:14 000 000 (N14), respectively, in the Tai lake region of China. Both format soil units were used for regional SOC pool simulation with DeNitrification-DeComposition (DNDC) process-based model, which runs span the time period 1982 to 2000 at the six map scales, respectively. Four indices, soil type number (STN) and area (AREA), average SOC density (ASOCD) and total SOC stocks (SOCS) of surface paddy soils simulated with the DNDC, were attributed from all these soil polygon and grid units, respectively. Subjecting to the four index values (IV) from the parent polygon units, the variation of an index value (VIV, %) from the grid units was used to assess its dataset accuracy and redundancy, which reflects uncertainty in the simulation of SOC. Optimal soil grid unit resolutions were generated and suggested for the DNDC simulation of regional SOC pool, matching with soil polygon units map scales, respectively. With the optimal raster resolution the soil grid units dataset can hold the same accuracy as its parent polygon units dataset without any redundancy, when VIV indices was assumed as criteria to the assessment. An quadratic curve regression model y = -8.0 × 10-6x2 + 0.228x + 0.211 (R2 = 0.9994, p < 0.05) was revealed, which describes the relationship between optimal soil grid unit resolution (y, km) and soil polygon unit map scale (1:x). The knowledge may serve for grid partitioning of regions focused on the investigation and simulation of SOC pool dynamics at certain map scale.

  12. Freestanding midwifery unit versus obstetric unit

    DEFF Research Database (Denmark)

    Overgaard, Charlotte; Møller, Anna Margrethe; Fenger-Grøn, Morten

    2011-01-01

    low-risk women intending FMU birth and a matched control group of 839 low-risk women intending OU birth were included at the start of care in labour. OU women were individually chosen to match selected obstetric/socio-economic characteristics of FMU women. Analysis was by intention to treat. Main......Objective To compare perinatal and maternal morbidity and birth interventions in low-risk women giving birth in two freestanding midwifery units (FMUs) and two obstetric units (OUs). Design A cohort study with a matched control group. Setting The region of North Jutland, Denmark. Participants 839...... women were significantly less likely to experience an abnormal fetal heart rate (RR: 0.3, 95% CI 0.2 to 0.5), fetal–pelvic complications (0.2, 0.05 to 0.6), shoulder dystocia (0.3, 0.1 to 0.9), occipital–posterior presentation (0.5, 0.3 to 0.9) and postpartum haemorrhage >500 ml (0.4, 0.3 to 0...

  13. Provision of bereavement care in neonatal units in the United Kingdom.

    Science.gov (United States)

    Robertson, Meredith J P; Aldridge, Anne; Curley, Anna E

    2011-05-01

    To establish what bereavement care services are available in neonatal units in the United Kingdom and to establish the availability to staff (doctors, nurses, and chaplains) of bereavement education, training, communication, and multicultural support. For families who lose a baby in the neonatal period, the support they receive from hospital staff can be pivotal in their ability to cope with their grief. Hospital staff are not always trained to provide this support. Limited evidence is available regarding hospital-based bereavement care in neonatology or its impact on outcome. Questionnaire survey of selected doctors, nurses, and chaplains in 200 neonatal units in the United Kingdom. We had responses from 100% of neonatal units surveyed. Of 600 individuals, 320 responded; 11% of doctors had never received any formal training in bereavement care, compared with 0.8% of nurses and 1.2% and chaplains. In addition, 31% of respondents thought the training they received was inadequate. Knowledge of grief theorists was poor. Up to 99% of units were helping parents create memories through photographs or handprints. Parents were uniformly given the chance to be with their baby at the time of death (99% overall). Siblings were encouraged to be present 71% of the time; 75% of respondents felt that information about the needs of different faith groups was available. Formal psychological support was offered to 45% of families after bereavement. Studies have shown that parents value clear communication, education about grieving, and demonstrated emotional support by staff. Our study has shown that there are deficiencies in staff training and education in this area. Educators must promote the inclusion of content on bereavement/end-of-life care. Additional education on cultural issues would be helpful. Managing the bereavement process well to minimize morbidity for families and healthcare providers is an important challenge for the future.

  14. Shale gas policy in the United Kingdom: An argumentative discourse analysis

    International Nuclear Information System (INIS)

    Cotton, Matthew; Rattle, Imogen; Van Alstine, James

    2014-01-01

    Shale gas has become an energy policy priority in the United Kingdom in light of profitable extraction activities in the United States. Since 2012 the Coalition Government has created key economic drivers to encourage shale exploration, whilst growing activism in affected site communities has stirred significant media and academic commentary. This study examines the growing national debate as a matter of discourse, adopting an argumentative discourse analytic approach to assess data collected from stakeholder interviews (n=21) and key policy actor statements quoted in broadsheet newspapers. We explore three dominant “storylines” emerging in relation to shale gas policy: (1) “cleanliness and dirt” concerns the relative framing of the environmental benefits and harms of shale gas; (2) “energy transitions – pathways and diversions” concerns geographic metaphors of transitions to carbon intensive and low-carbon energy systems; and (3) “geographies of environmental justice” concerns divisions of economic benefit distribution, environmental impact and procedural fairness. We find that central government policy rhetoric emphasises economic development, regulatory oversight and distribution of benefits to site communities, whilst minimising discussion of the implications of shale gas for anthropogenic climate change. The role of these discourses in influencing shale gas policy is discussed. - Highlights: • We examine the discourses emerging in relation to shale gas policy in the United Kingdom. • We use a combination of stakeholder interviews and a broadsheet newspaper search. • Three “storylines” emerge: “cleanliness and dirt”, “energy transitions” and “geographies of environmental justice”. • UK policy rhetoric emphasises economic development, regulatory oversight and distribution of benefits to site communities. • The issue of climate change is marginalised in UK shale gas policy

  15. Nuclear power generation costs in the United States of America

    International Nuclear Information System (INIS)

    Willis, W.F.

    1983-01-01

    Increasing world energy prices and shortages of fuel resources make the utilization of nuclear power extremely important. The United States nuclear power industry represents the largest body of nuclear power experience in the world. Analysis of the recent United States experience of substantial increases in the cost of nuclear power generation provides good insight into the interdependence of technological, financial, and institutional influences and their combined impact on the economic viability of nuclear power generation. The various factors influencing ultimate generation costs, including construction cost, fuel cost, regulatory reviews, and siting considerations are discussed, and their relative impacts are explored, including discussion of design complexity and related regulatory response. A closer look into the recent relatively high escalation of nuclear plant construction costs shows how differing economic conditions can affect the relative cost effectiveness of various methods of power generation. The vulnerability of capital-intensive, long-lead-time projects to changes in economic conditions and uncertainty in future power demands is discussed. Likewise, the pitfalls of new designs and increased sophistication are contrasted to the advantages which result from proven designs, reliable engineering, and shorter lead times. The value of reliable architect-engineers experienced in the design and construction of the plant is discussed. A discussion is presented of additional regulatory requirements stemming from public safety aspects of nuclear power. These include recognition of requirements for the very large effort for quality assurance of materials and workmanship during plant construction and operation. Likewise, a discussion is included of the demanding nature of operations, maintenance, and modification of plants during the operational phase because of the need for highly qualified operations and maintenance personnel and strict quality assurance

  16. 7 CFR 65.255 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false United States. 65.255 Section 65.255 Agriculture..., PEANUTS, AND GINSENG General Provisions Definitions § 65.255 United States. United States means the 50... United States. ...

  17. Inlet Geomorphology Evolution Work Unit

    Science.gov (United States)

    2015-10-30

    Coastal Inlets Research Program Inlet Geomorphology Evolution Work Unit The Inlet Geomorphology Evolution work unit of the CIRP develops methods...morphologic response. Presently, the primary tool of the Inlet Geomorphology Evolution work unit is the Sediment Mobility Tool (SMT), which allows the user

  18. A large economic liquid metal reactor for United States utilities

    International Nuclear Information System (INIS)

    Rodwell, E.

    1985-01-01

    The United States has demonstrated its ability to build and operate small and medium sized liquid metal reactors and continues to operate the Experimental Breeder Reactor II and the Fast Flux Test Facility to demonstrate long life fuel designs. Similar-sized liquid metal reactors in Europe have been followed by a step-up to the 1200 MWe capacity of the Superphenix plant. To permit the United States to make a similar step-up in capacity, a 1320 MWe liquid metal reactor plant has been designed with the main emphasis on minimizing the specific capital cost in order to be competitive with light water reactor plant and fossil plant alternatives. The design is based on a four parallel heat transport loops arrangement and complies with current regulatory requirements. The primary heat transport loops are now being integrated into the reactor vessel to achieve further reduction in the capital cost

  19. 7 CFR 1150.106 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true United States. 1150.106 Section 1150.106 Agriculture... Order Definitions § 1150.106 United States. United States means the 48 contiguous States in the continental United States. ...

  20. A functional intranet for the United States Coast Guard Unit

    OpenAIRE

    Hannah, Robert Todd.

    1998-01-01

    Approved for public release; distribution in unlimited. This thesis describes the complete development process of a friendly functional Intranet for an operational United States Coast Guard (USCG) electronic Support Unit (ESU) in Alameda, California. The final product is suitable for immediate use. It may also be used as a prototype for future Intranet development efforts. The methodology used to develop a finished, working product provides the core subject matter for this thesis. The disc...

  1. 76 FR 79228 - Combined Licenses at William States Lee III Nuclear Station Site, Units 1 and 2; Duke Energy...

    Science.gov (United States)

    2011-12-21

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 52-018 and 52-019; NRC-2008-0170] Combined Licenses at William States Lee III Nuclear Station Site, Units 1 and 2; Duke Energy Carolinas, LLC AGENCY: Nuclear.... SUMMARY: Notice is hereby given that the U.S. Nuclear Regulatory Commission (NRC) and the U.S. Army Corps...

  2. 78 FR 39279 - United States Department of Energy; Bonneville Power Administration; Notice of Petition for...

    Science.gov (United States)

    2013-07-01

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. NJ13-10-000] United States Department of Energy; Bonneville Power Administration; Notice of Petition for Declaratory Order Take notice... (OATT) and a Petition for Declaratory Order requesting the Commission find that Bonneville's OATT, as...

  3. United States Nuclear Regulatory Commission information digest: 1997 edition. Volume 9

    International Nuclear Information System (INIS)

    1997-05-01

    The Nuclear Regulatory Commission Information Digest (digest) provides a summary of information about the US Nuclear Regulatory Commission (NRC), NRC's regulatory responsibilities, NRC licensed activities, and general information on domestic and world-wide nuclear energy. The digest, published annually, is a compilation of nuclear- and NRC-related data and is designed to provide a quick reference to major facts about the agency and the industry it regulates. In general, the data cover 1975 through 1996, with exceptions noted. Information on generating capacity and average capacity factor for operating US commercial nuclear power reactors is obtained from monthly operating reports that are submitted directly to the NRC by the licensee. This information is reviewed by the NRC for consistency only and no independent validation and/or verification is performed

  4. Upgrade of KNPEC no.2 Simulator for Kori Unit 3 Power Uprating

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin-Hyuk; Lee, Seung-Ho [KEPRI, Daejeon (Korea, Republic of)

    2007-07-01

    Kori-Unit 3 and 4 is preparing the operation of the power-uprating (2900MWt), and therefore the Korea regulatory body(KINS) requested the operator training with the simulator reflecting the power-uprating. As a result of the intensive research and expertise of KEPRI on the simulators, KEPRI accomplished the upgrade project of KNPEC no.2 simulator for Kori-Unit 3 power-uprating. This project includes various high-tech methods incorporating - realtime neutronics model based on MASTER (Multi-purpose Analyzer for Static and Transient Effects of Reactors) code, best-estimate neutronics code by the KINS, (By using the RMASTER, the precision of the simulation of the neutron behaviors in the core is highly improved.) - betterment of the reactor coolant system and the balance-of-plant system - modification of the corresponding setpoints due to the power-uprating And the acceptance test procedure (ATP) was successfully carried out through the integration of system models and its performance tests. Through the success of this project, the operator training for the power uprating of the Kori-Unit 3 will be accomplished before its power operation and, after all, this simulator will contribute to the safe operation for the power-uprating of the Kori-Unit 3 and 4.

  5. NZG 201 portable spectrometric unit

    International Nuclear Information System (INIS)

    Jursa, P.; Novakova, O.; Slezak, V.

    The NZG 201 spectrometric unit is a portable single-channel processing unit supplied from the mains or a battery which allows the qualitative and quantitative measurement of different types of ionizing radiation when connected to a suitable detection unit. The circuit layout and the choice of control elements makes the spectrometric unit suitable for use with scintillation detector units. The spectrometric unit consists of a pulse amplifier, an amplitude pulse analyzer, a pulse counter, a pulse rate counter with an output for a recorder, a high voltage source and a low voltage source. The block diagram is given. All circuits are modular and are mounted on PCB's. The apparatus is built in a steel cabinet with a raised edge which protects the control elements. The linear pulse amplifier has a maximum gain of 1024, the pulse counter has a maximum capacity of 10 6 -1 imp and time resolution better than 0.5 μs. The temperature interval at which the apparatus is operational is 0 to 45 degC, its weight is 12.5 kg and dimensions 36x280x310 mm, energy range O.025 to 2.5 MeV, for 137 Cs the energy resolution is 8 to 10%. The spectrometric unit NZG 2O1 may, with regard to its parameters, number and range of control elements, be used as a universal measuring unit. (J.P.)

  6. Unit Cost Compendium Calculations

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Unit Cost Compendium (UCC) Calculations raw data set was designed to provide for greater accuracy and consistency in the use of unit costs across the USEPA...

  7. 7 CFR 1212.31 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1212.31 Section 1212.31 Agriculture..., Consumer Education, and Industry Information Order Definitions § 1212.31 United States. “United States... territories and possessions of the United States. ...

  8. Pressurized thermal shock evaluation of the Calvert Cliffs Unit 1 Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, L [ed.

    1985-09-01

    An evaluation of the risk to the Calvert Cliffs Unit 1 nuclear power plant due to pressurized thermal shock (PTS) has been completed by Oak Ridge National Laboratory (ORNL) with the assistance of several other organizations. This evaluation was part of a Nuclear Regulatory Commission program designed to study the PTS risk to three nuclear plants, the other two plants being Oconee Unit 1 and H.B. Robinson Unit 2. The specific objectives of the program were to (1) provide a best estimate of the frequency of a through-the-wall crack in the pressure vessel at each of the three plants, together with the uncertainty in the estimated frequency and its sensitivity to the variables used in the evaluation; (2) determine the dominant overcooling sequences contributing to the estimated frequency and the associated failures in the plant systems or in operator actions; and (3) evaluate the effectiveness of potential corrective measures.

  9. Pressurized thermal shock evaluation of the Calvert Cliffs Unit 1 Nuclear Power Plant

    International Nuclear Information System (INIS)

    Abbott, L.

    1985-09-01

    An evaluation of the risk to the Calvert Cliffs Unit 1 nuclear power plant due to pressurized thermal shock (PTS) has been completed by Oak Ridge National Laboratory (ORNL) with the assistance of several other organizations. This evaluation was part of a Nuclear Regulatory Commission program designed to study the PTS risk to three nuclear plants, the other two plants being Oconee Unit 1 and H.B. Robinson Unit 2. The specific objectives of the program were to (1) provide a best estimate of the frequency of a through-the-wall crack in the pressure vessel at each of the three plants, together with the uncertainty in the estimated frequency and its sensitivity to the variables used in the evaluation; (2) determine the dominant overcooling sequences contributing to the estimated frequency and the associated failures in the plant systems or in operator actions; and (3) evaluate the effectiveness of potential corrective measures

  10. 7 CFR 1206.23 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1206.23 Section 1206.23 Agriculture... INFORMATION Mango Promotion, Research, and Information Order Definitions § 1206.23 United States. United... Rico, and the territories and possessions of the United States. ...

  11. Flywheel and power unit

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, R.W.

    1992-10-28

    A power unit, e.g. for an electrically driven vehicle, incorporates a flywheel for storing kinetic energy and a battery for storing electrical energy. The battery is incorporated as a substantial part of the rotating mass of the flywheel. Preferably the unit further includes an electrical machine being a motor or generator or machine operable either as a motor or a generator for transferring energy between the battery and the flywheel and/or for the input or output of rotary energy therefrom or thereto. The motor may be used for powering the flywheel and may also operate in a regenerative mode for recharging the unit on de-acceleration of the vehicle. The unit of the invention may also be utilized as an electrical stored power source, e.g. wind or water driven. (author)

  12. Investigation and management of gastro-oesophageal reflux in United Kingdom neonatal intensive care units.

    Science.gov (United States)

    Rossor, Thomas; Andradi, Gwendolyn; Bhat, Ravindra; Greenough, Anne

    2018-01-01

    In 2004, wide variation in the investigation and management of gastro-oesophageal reflux (GOR) of infants on UK major neonatal units was demonstrated. Our aim was to resurvey neonatal practitioners to determine current practice and whether it was now evidence based. A questionnaire was sent to all 207 UK neonatal units. Responses were obtained from 84% of units. The most frequent 'investigation' was a trial of therapy (83% of units); pH studies were used in 38%, upper GI contrast studies in 19% and multichannel intraluminal impedance (MII)/pH studies in 5%. Only six units suggested a threshold for an abnormal pH study and two units for an abnormal MII study. Infants were commenced on antireflux medication without investigation always in 32% of units, often in 29%, occasionally in 19% and only never in 1%. Gaviscon was used as first line treatment in 60% of units, and other medications included ranitidine in 53%, thickening agents in 27%, proton pump inhibitors in 23%, domperidone in 22% and erythromycin in 6%. There remains a wide variation in diagnostic and treatment strategies for infants with suspected GOR on neonatal intensive care units, emphasising the need for randomised trials to determine appropriate GOR management. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  13. Associations among unit leadership and unit climates for implementation in acute care: a cross-sectional study.

    Science.gov (United States)

    Shuman, Clayton J; Liu, Xuefeng; Aebersold, Michelle L; Tschannen, Dana; Banaszak-Holl, Jane; Titler, Marita G

    2018-04-25

    Nurse managers have a pivotal role in fostering unit climates supportive of implementing evidence-based practices (EBPs) in care delivery. EBP leadership behaviors and competencies of nurse managers and their impact on practice climates are widely overlooked in implementation science. The purpose of this study was to examine the contributions of nurse manager EBP leadership behaviors and nurse manager EBP competencies in explaining unit climates for EBP implementation in adult medical-surgical units. A multi-site, multi-unit cross-sectional research design was used to recruit the sample of 24 nurse managers and 553 randomly selected staff nurses from 24 adult medical-surgical units from 7 acute care hospitals in the Northeast and Midwestern USA. Staff nurse perceptions of nurse manager EBP leadership behaviors and unit climates for EBP implementation were measured using the Implementation Leadership Scale and Implementation Climate Scale, respectively. EBP competencies of nurse managers were measured using the Nurse Manager EBP Competency Scale. Participants were emailed a link to an electronic questionnaire and asked to respond within 1 month. The contributions of nurse manager EBP leadership behaviors and competencies in explaining unit climates for EBP implementation were estimated using mixed-effects models controlling for nurse education and years of experience on current unit and accounting for the variability across hospitals and units. Significance level was set at α < .05. Two hundred sixty-four staff nurses and 22 nurse managers were included in the final sample, representing 22 units in 7 hospitals. Nurse manager EBP leadership behaviors (p < .001) and EBP competency (p = .008) explained 52.4% of marginal variance in unit climate for EBP implementation. Leadership behaviors uniquely explained 45.2% variance. The variance accounted for by the random intercepts for hospitals and units (p < .001) and years of nursing experience in current unit

  14. Multi-unit Operations in Non-Nuclear Systems: Lessons Learned for Small Modular Reactors

    Energy Technology Data Exchange (ETDEWEB)

    OHara J. M.; Higgins, J.; DAgostino, A.

    2012-01-17

    The nuclear-power community has reached the stage of proposing advanced reactor designs to support power generation for decades to come. Small modular reactors (SMRs) are one approach to meet these energy needs. While the power output of individual reactor modules is relatively small, they can be grouped to produce reactor sites with different outputs. Also, they can be designed to generate hydrogen, or to process heat. Many characteristics of SMRs are quite different from those of current plants and may be operated quite differently. One difference is that multiple units may be operated by a single crew (or a single operator) from one control room. The U.S. Nuclear Regulatory Commission (NRC) is examining the human factors engineering (HFE) aspects of SMRs to support licensing reviews. While we reviewed information on SMR designs to obtain information, the designs are not completed and all of the design and operational information is not yet available. Nor is there information on multi-unit operations as envisioned for SMRs available in operating experience. Thus, to gain a better understanding of multi-unit operations we sought the lesson learned from non-nuclear systems that have experience in multi-unit operations, specifically refineries, unmanned aerial vehicles and tele-intensive care units. In this paper we report the lessons learned from these systems and the implications for SMRs.

  15. United Nations opens gender coordinating unit for Afghanistan.

    Science.gov (United States)

    Morris, K

    1999-02-06

    The UN has created a gender coordinating unit for Afghanistan in an effort to combat some problems encountered by women and girls in the country. Reports continue to come in of women in Afghanistan being denied the right to work, to be educated, and to have access to medical care. The gap in education between men and women continues to widen as a result of edicts issued by Taliban authorities banning girls from attending formal schools and female teachers from working. The situation has grown worse since the UN and nongovernmental organizations (NGOs) withdrew international workers last year due to security concerns. Although a UN mission will travel to the country this week to discuss the return of international staff, the gender coordinating unit will for now have to work out of Islamabad, Pakistan. The unit will create guidelines for gender mainstreaming, a strategy in which mainstream policies and resource allocations are changed to reflect the principle of gender equality. Other goals include setting realistic objectives for gender activities, working with partners on pilot projects, and establishing minimum standards for best practices. MERLIN, a NGO with a primary health care program run by local staff in the Taliban-controlled province of Farah, welcomes the move.

  16. Functional unit for a processor

    NARCIS (Netherlands)

    Rohani, A.; Kerkhoff, Hans G.

    2013-01-01

    The invention relates to a functional unit for a processor, such as a Very Large Instruction Word Processor. The invention further relates to a processor comprising at least one such functional unit. The invention further relates to a functional unit and processor capable of mitigating the effect of

  17. RCRA facility investigation/corrective measures study work plan for the 200-UP-2 Operable Unit, Hanford Site, Richland, Washington

    International Nuclear Information System (INIS)

    1993-06-01

    The 200-UP-2 Operable Unit is one of two source operable units at the U Plant Aggregate Area at the Hanford Site. Source operable units include waste management units and unplanned release sites that are potential sources of radioactive and/or hazardous substance contamination. This work plan, while maintaining the title RFI/CMS, presents the background and direction for conducting a limited field investigation in the 200-UP-2 Operable Unit, which is the first part of the process leading to final remedy selection. This report discusses the background, prior recommendations, goals, organization, and quality assurance for the 200-UP-2 Operable Unit Work Plan. The discussion begins with a summary of the regulatory framework and the role of the work plan. The specific recommendations leading into the work plan are then addressed. Next, the goals and organization of the report are discussed. Finally, the quality assurance and supporting documentation are presented

  18. Smart Rocking Armour Units

    OpenAIRE

    Hofland, B.; Arefin, Syed Shamsil; van der Lem, Cock; van gent, Marcel

    2018-01-01

    This paper describes a method to measure the rocking motion of lab-scale armour units. Sensors as found in mobile phones are used. These sensors, data-storage and battery are all embedded in the model units, such that they can be applied without wires attached to them. The technique is applied to double-layer units in order to compare the results to the existing knowledge for this type of armour layers. In contrast to previous research, the gyroscope reading is used to determine the (rocking)...

  19. Vogtle Unit 1 readiness review: Assessment of Georgia Power Company readiness review pilot program

    International Nuclear Information System (INIS)

    Lewis, G.

    1987-09-01

    Georgia Power Company (GPC) performed a readiness review at Vogtle Unit 1 as a pilot program. The pilot program was a new and innovative approach for the systematic and disciplined review, with senior management involvement, of GPC's implementation of design, construction, and operational readiness processes. The program's principal objective was to increase the level of assurance that quality programs at Vogtle Unit 1 have been accomplished in accordance with regulatory requirements. This report assesses the effectiveness of the GPC's readiness review pilot program (RRPP) at Vogtle Unit 1. It includes (1) an overview of what was experienced during the program's implementation, (2) an assessment of how well program objectives were met, and (3) lessons learned on the future use of the readiness review concept. Overall, GPC and the NRC staff believe that the RRPP at Vogtle Unit 1 was a success and that the program provided significant added assurance that Vogtle Unit 1 licensing commitments and NRC regulations have been adequately implemented. Although altering the NRC licensing review process for the few plants still in the construction pipeline may not be appropriate, licensees may benefit significantly by performing readiness reviews on their own initiative as GPC did for Vogtle. (7 refs.)

  20. 7 CFR 1250.308 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1250.308 Section 1250.308 Agriculture... Research and Promotion Order Definitions § 1250.308 United States. United States means the 48 contiguous States of the United States of America and the District of Columbia. ...

  1. 7 CFR 1205.23 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1205.23 Section 1205.23 Agriculture... Procedures for Conduct of Sign-up Period Definitions § 1205.23 United States. The term United States means the 50 states of the United States of America. Procedures ...

  2. United States housing, 2012

    Science.gov (United States)

    Delton Alderman

    2013-01-01

    Provides current and historical information on housing market in the United States. Information includes trends for housing permits and starts, housing completions for single and multifamily units, and sales and construction. This report will be updated annually.

  3. Mechanical strainer unit

    International Nuclear Information System (INIS)

    Kraeling, J.B.; Netkowicz, R.J.; Schnall, I.H.

    1983-01-01

    The mechanical strainer unit is connected to a flanged conduit which originates in and extends out of a suppression chamber in a nuclear reactor. The strainer includes a plurality of centrally apertured plates positioned along a common central axis and in parallel and spaced relationship. The plates have a plurality of bores radially spaced about the central axis. Spacer means such as washers are positioned between adjacent plates to maintain the plates is spaced relationship and form communicating passages of a predetermined size to the central apertures. Connecting means such as bolts or studs extend through the aligned bores to maintain the unit in assembled relationship and secure the unit to the pipe. By employing perforated plates and blocking off certain of the communicating passages, a dual straining effect can be achieved

  4. Snakes: An Integrated Unit Plan.

    Science.gov (United States)

    Lawrence, Lisa

    This document presents an integrated unit plan on snakes targeting second grade students. Objectives of the unit include developing concepts of living things, understanding the contribution and importance of snakes to the environment, and making connections between different disciplines. The unit integrates the topic of snakes into the areas of…

  5. The effects of unit morale and interpersonal relations on conflict in the nursing unit.

    Science.gov (United States)

    Cox, K B

    2001-07-01

    Health care organizations face major changes, and these changes are likely to increase conflict in organizations. Although numerous studies have focused on conflict management, few have considered causes and effect of conflict in nursing units. The investigation tested a structural equation that examined the relationships among individual and contextual variables and intragroup conflict, job satisfaction, team performance effectiveness, and anticipated turnover. The nonrandom sample consisted of 141 nurses employed on 13 inpatient units at a state-supported, 597-bed academic medical centre in a southeastern city. Intragroup conflict was higher on smaller units with a higher ratio of RNs to total staff. Intragroup conflict was not associated with satisfaction with pay or anticipated turnover. In the final model, the unit morale and interpersonal relations dimension of team performance effectiveness was negatively associated with intragroup conflict and anticipated turnover, and positively associated with satisfaction with pay. High perceptions of unit morale and interpersonal relations buffered the effect of unit size and skill mix on intragroup conflict. Goodness of fit statistics indicated a good fit of the model to data. The findings have implications for nursing educators and administrators, and provide direction for future research.

  6. Analysis of core damage frequency from internal events: Surry, Unit 1

    International Nuclear Information System (INIS)

    Harper, F.T.

    1986-11-01

    This document contains the accident sequence analyses for Surry, Unit 1; one of the reference plants being examined as part of the NUREG-1150 effort by the Nuclear Regulatory Commission (NRC). NUREG-1150 will document the risk of a selected group of nuclear power plants. As part of that work, this report contains the overall core damage frequency estimate for Surry, Unit 1, and the accompanying plant damage state frequencies. Sensitivity and uncertainty analyses provide additional insights regarding the dominant contributors to the Surry core damage frequency estimate. The numerical results are driven to some degree by modeling assumptions and data selection for issues such as reactor coolant pump seal LOCAs, common cause failure probabilities, and plant response to station blackout and loss of electrical bust initiators. The sensitivity studies explore the impact of alternate theories and data on these issues

  7. Grandeurs, dimensions, et conversions d'unités Quantities, Dimensions and Units Conversions

    Directory of Open Access Journals (Sweden)

    Bronner C.

    2006-11-01

    Full Text Available Il n'est plus besoin de démontrer que le Système International d'Unités (SI est un fait. Il est normalement enseigné dans les lycées et universités. Les scientifiques l'utilisent systématiquement dans leurs publications; les nouveaux livres et banques de données s'en servent couramment. Cependant, certaines industries (la pétrolière entre autres continuent à se servir de systèmes techniques. On trouve dans des archives de vieilles données ou des spécifications d'usines qui ont été faites dans d'autres systèmes. Il n'est pas rare, dans la vie professionnelle, de rencontrer un problème où une unité doit être transformée. Cet article souhaite aider les personnes qui doivent résoudre ce genre d'écueil en leur présentant une vision globale des différents systèmes d'unités qui ont historiquement existé. Une définition des unités, soit traditionnelles, soit étranges, accompagne également l'article. L'aide la plus importante sera sans doute trouvée dans le programme inclus dans une disquette. Un logiciel complet, sous Windows, permettra à quiconque de résoudre, sans erreur, son problème de conversion d'unité. La technique de conversion, basée sur l'utilisation du calcul dimensionnel, et utilisée dans le programme, est également expliquée. It is not longer necessary to prove that the International System of Units (SI is a fact. It is normally used in schools and universities. Scientists systematically use SI in their publications. New books and databases are commonly built on it. Meanwhile, some industries (oil companies among others keep on using technical systems. It is possible to find old data and plant designs that use other systems. It is not uncommon, in professional life, to find a problem in which units need to be transformed. This article aims to help people who have to solve this kind of difficulty, by giving an overview of the different unit systems. A description of traditional and unusual units is

  8. 31 CFR 542.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 542.310 Section 542.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....310 United States. The term United States means the United States, its territories and possessions...

  9. 31 CFR 548.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 548.310 Section 548.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....310 United States. The term United States means the United States, its territories and possessions...

  10. 31 CFR 546.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 546.310 Section 546.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....310 United States. The term United States means the United States, its territories and possessions...

  11. 31 CFR 586.318 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 586.318 Section 586...) KOSOVO SANCTIONS REGULATIONS General Definitions § 586.318 United States. The term United States means the United States, its territories and possessions, and all areas under the jurisdiction or authority...

  12. 31 CFR 537.318 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 537.318 Section 537.318 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....318 United States. The term United States means the United States, its territories and possessions...

  13. 31 CFR 597.318 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 597.318 Section 597... General Definitions § 597.318 United States. The term United States means the United States, its territories, states, commonwealths, districts, and possessions, and all areas under the jurisdiction or...

  14. 31 CFR 585.316 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 585.316 Section 585.316 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... General Definitions § 585.316 United States. The term United States means the United States, its...

  15. 31 CFR 575.319 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 575.319 Section 575.319 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....319 United States. The term United States means the United States, its territories and possessions...

  16. 31 CFR 539.312 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 539.312 Section 539.312 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... General Definitions § 539.312 United States. The term United States means the United States, its...

  17. 31 CFR 551.309 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 551.309 Section 551.309 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....309 United States. The term United States means the United States, its territories and possessions...

  18. 7 CFR 1219.26 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1219.26 Section 1219.26 Agriculture..., AND INFORMATION Hass Avocado Promotion, Research, and Information Order Definitions § 1219.26 United States. United States means collectively the several 50 States of the United States, the District of...

  19. 31 CFR 587.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 587.310 Section 587...) MILOSEVIC SANCTIONS REGULATIONS General Definitions § 587.310 United States. The term United States means the United States, its territories and possessions, and all areas under the jurisdiction or authority...

  20. 31 CFR 547.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 547.310 Section 547.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... General Definitions § 547.310 United States. The term United States means the United States, its...

  1. Large component regulatory relief in the United States

    International Nuclear Information System (INIS)

    Williams, J.L.; Boyle, R.W.

    2004-01-01

    The dismantling of retired nuclear power and test facilities required the transport of reactor vessels, reactor vessel heads, pressurizers, reactor coolant pumps, and steam generators; whereas the replacement of degraded components to continue operations has been generally limited to pressurized water reactor steam generators, and more recently, reactor heads. These components are quite large and massive, measuring up to 20 feet in diameter and 70 feet in length and weighing 50 to 600 tons. Issue Several issues arose, due to the implementation of the 1985 IAEA transportations regulations in the United States, on the practical matters of how to characterize the components and comply with the transportation regulations. The concept of a Surface Contaminated Object (SCO) was new to many in the U.S., and the large components were not readily amenable to transportation under the regulations. It was apparent that most of the components should be considered as SCO. However, it was not certain that the contamination limits for inaccessible areas could be met due to non-uniform contamination deposition; nor could the interior areas be readily surveyed without on-site dismantlement of the large component. Additionally, while the components were generally substantial in design and construction due to their use as pressure vessels under other codes, the current regulations required packages that met tests such as for stacking and free drop that would pose severe engineering challenges, prohibitive costs, or logistical difficulties during transport, due to the size and weight of the components being transport

  2. Design of hydraulic recuperation unit

    Directory of Open Access Journals (Sweden)

    Jandourek Pavel

    2016-01-01

    Full Text Available This article deals with design and measurement of hydraulic recuperation unit. Recuperation unit consist of radial turbine and axial pump, which are coupled on the same shaft. Speed of shaft with impellers are 6000 1/min. For economic reasons, is design of recuperation unit performed using commercially manufactured propellers.

  3. 31 CFR 598.317 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 598.317 Section 598.317 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 598.317 United States. The term United States means the United States, its territories and...

  4. 31 CFR 596.312 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 596.312 Section 596.312 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... General Definitions § 596.312 United States. The term United States means the United States, including its...

  5. 31 CFR 538.314 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 538.314 Section 538.314 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... § 538.314 United States. The term United States means the United States, its territories and possessions...

  6. 31 CFR 543.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 543.310 Section 543.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 543.310 United States. The term United States means the United States, its territories and...

  7. 31 CFR 594.313 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 594.313 Section 594.313 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 594.313 United States. The term United States means the United States, its territories and...

  8. 31 CFR 588.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 588.310 Section 588.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 588.310 United States. The term United States means the United States, its territories and...

  9. 31 CFR 536.315 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 536.315 Section 536.315 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 536.315 United States. The term United States means the United States, its territories and...

  10. 31 CFR 544.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 544.310 Section 544.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... REGULATIONS General Definitions § 544.310 United States. The term United States means the United States, its...

  11. 31 CFR 545.313 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 545.313 Section 545.313 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 545.313 United States. The term United States means the United States, its territories and...

  12. 31 CFR 595.314 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 595.314 Section 595.314 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... § 595.314 United States. The term United States means the United States, its territories and possessions...

  13. 31 CFR 560.307 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 560.307 Section 560.307 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... § 560.307 United States. The term United States means the United States, including its territories and...

  14. 31 CFR 593.311 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 593.311 Section 593.311 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... REGULATIONS General Definitions § 593.311 United States. The term United States means the United States, its...

  15. 31 CFR 541.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 541.310 Section 541.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... § 541.310 United States. The term United States means the United States, its territories and possessions...

  16. 22 CFR 120.13 - United States.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false United States. 120.13 Section 120.13 Foreign... United States. United States, when used in the geographical sense, includes the several states, the Commonwealth of Puerto Rico, the insular possessions of the United States, the District of Columbia, the...

  17. 31 CFR 540.313 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 540.313 Section 540.313 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... REGULATIONS General Definitions § 540.313 United States. The term United States means the United States, its...

  18. United States natural gas markets, contracts and risks: What lessons for the European Union and Asia-Pacific natural gas markets?

    International Nuclear Information System (INIS)

    Talus, Kim

    2014-01-01

    The article examines the natural gas markets of the United States, the European Union and the Asia-Pacific region and their regulation and contractual structures. The article's main focus is on the United States natural gas markets. The European Union and Asia-Pacific markets are compared to this more developed market. By comparing the physical and ideological characteristics of, and differences between, the three main international gas markets, the article exposes the limits of regulatory and contractual transplants in this area of law and policy. Each of these markets is unique, which limits the opportunities for modelling certain market institutions on the basis of the more developed markets in the United States. This applies for both the EU and the Asia-Pacific region. - Highlights: • Differences in the physical markets impact regulation. • Regulatory transplants have risks. • The approach in energy policy should be based on “Law-in-Context” approach

  19. Hanford Site Waste Management Units Report

    International Nuclear Information System (INIS)

    1991-01-01

    This Hanford Site Waste Management Units Report (HSWMUR) was originated to provide information responsive to Section 3004(u) of the Hazardous and Solid Waste Amendments (HSWA) of the 1984 United States Code (USC). The report provides a comprehensive inventory of all types of waste management units at the Hanford Site and consists of waste disposal units, including (1) Resource Conservation and Recovery Act of 1976 (RCRA) disposal units, (2) Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) disposal units, (3) unplanned releases, (4) inactive contaminated structure, (5) RCRA treatment and storage units, and (6) other storage areas. Because of the comprehensive nature of this report, the listing of sites is more extensive than required by Section 3004(u) of HSWA. In support of the Hanford RCRA permit, a field was added to designate whether the waste management unit is a solid waste management unit (SWMU). As SWMUs are identified, they will added to the Hanford Waste Information Data System (WIDS), which is the database supporting this report, and added to the report at its next annual update. A quality review of the WIDS was conducted this past year. The review included checking all data against their reference and making appropriate changes, updating the data elements using the most recent references, marking duplicate units for deletion, and addition additional information. 6 refs

  20. Hanford Site Waste Management Units Report

    International Nuclear Information System (INIS)

    1991-01-01

    This Hanford Site Waste Management Units Report (HSWMUR) was originated to provide information responsive to Section 3004(u) of the Hazardous and Solid Waste Amendments (HSWA) of the 1984 United States Code (USC). The report provides a comprehensive inventory of all types of waste management units at the Hanford Site and consists of waste disposal units, including (1) Resource Conservation and Recovery Act of 1976 (RCRA) disposal units, (2) Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) disposal units, (3) unplanned releases, (4) inactive contaminated structures, (5) RCRA treatment and storage units, and (6) other storage areas. Because of the comprehensive nature of this report, the listing of sites is more extensive than required by Section 3004(u) of HSWA. In support of the Hanford RCRA permit, a field was added to designate whether the waste management unit is a solid waste management unit (SWMU). As SWMUs are identified, they will added to the Hanford Waste Information Data System (WIDS), which is the database supporting this report, and added to the report at its next annual update. A quality review of the WIDS was conducted this past year. The review included checking all data against their reference and making appropriate changes, updating the data elements using the most recent references, marking duplicate units for deletion, and adding additional information. 6 refs

  1. 75 FR 8753 - Carolina Power & Light Company, Brunswick Steam Electric Plant, Units 1 and 2; Environmental...

    Science.gov (United States)

    2010-02-25

    ... Dusenbury of the North Carolina Department of Environment and Natural Resources regarding the environmental... & Light Company, Brunswick Steam Electric Plant, Units 1 and 2; Environmental Assessment and Finding of No... identification of licensing and regulatory actions requiring environmental assessments,'' the NRC prepared an...

  2. The Auto Industry. Grade Nine. Resource Unit (Unit IV). Project Social Studies.

    Science.gov (United States)

    Minnesota Univ., Minneapolis. Project Social Studies Curriculum Center.

    Unit four of this curriculum plan for ninth grade social studies outlines a study of the automobile industry in the United States. Objectives state the desired generalizations, skills, and attitudes to be developed. A condensed outline of course content precedes expanded guidelines for teaching procedures and suggested resource materials. A…

  3. 31 CFR 592.311 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 592.311 Section 592... § 592.311 United States. The term United States, when used in the geographic sense, means the several States, the District of Columbia, and any commonwealth, territory, or possession of the United States. ...

  4. Waste management units - Savannah River Site

    International Nuclear Information System (INIS)

    1989-10-01

    This report is a compilation of worksheets from the waste management units of Savannah River Plant. Information is presented on the following: Solid Waste Management Units having received hazardous waste or hazardous constituents with a known release to the environment; Solid Waste Management Units having received hazardous waste or hazardous constituents with no known release to the environment; Solid Waste Management Units having received no hazardous waste or hazardous constituents; Waste Management Units having received source; and special nuclear, or byproduct material only

  5. 7 CFR 1205.313 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1205.313 Section 1205.313 Agriculture... Research and Promotion Order Definitions § 1205.313 United States. United States means the 50 States of the United States of America. [31 FR 16758, Dec. 31, 1966. Redesignated at 56 FR 64472, Dec. 10, 1991] ...

  6. History of United States Energy. A Basic Teaching Unit on Energy. Revised.

    Science.gov (United States)

    McDermott, Hugh, Ed.; Scharmann, Larry, Ed.

    Intended as a supplement to the units "Oil: Fuel of the Past" and "Coal: Fuel of the Past, Hope of the Future," this 3-4 day unit contains three activities which briefly explain the chronological development of energy resources and the formation and development of the Organization of Petroleum Exporting Countries (OPEC). The…

  7. A mitotically inheritable unit containing a MAP kinase module.

    Science.gov (United States)

    Kicka, Sébastien; Bonnet, Crystel; Sobering, Andrew K; Ganesan, Latha P; Silar, Philippe

    2006-09-05

    Prions are novel kinds of hereditary units, relying solely on proteins, that are infectious and inherited in a non-Mendelian fashion. To date, they are either based on autocatalytic modification of a 3D conformation or on autocatalytic cleavage. Here, we provide further evidence that in the filamentous fungus Podospora anserina, a MAP kinase cascade is probably able to self-activate and generate C, a hereditary unit that bears many similarities to prions and triggers cell degeneration. We show that in addition to the MAPKKK gene, both the MAPKK and MAPK genes are necessary for the propagation of C, and that overexpression of MAPK as that of MAPKKK facilitates the appearance of C. We also show that a correlation exists between the presence of C and localization of the MAPK inside nuclei. These data emphasize the resemblance between prions and a self-positively regulated cascade in terms of their transmission. This thus further expands the concept of protein-base inheritance to regulatory networks that have the ability to self-activate.

  8. The Changing Face of Tobacco Use Among United States Youth

    OpenAIRE

    Lauterstein, Dana; Hoshino, Risa; Gordon, Terry; Watkins, Beverly-Xaviera; Weitzman, Michael; Zelikoff, Judith

    2014-01-01

    Tobacco use, primarily in the form of cigarettes, is the leading cause of preventable morbidity and mortality in the United States (U.S.). The adverse effects of tobacco use began to be recognized in the 1940’s and new hazards of active smoking and secondhand smoke (SHS) exposure from cigarettes continue to be identified to this day. This has led to a sustained and wide-ranging array of highly effective regulatory, public health, and clinical efforts that have been informed by extensive scien...

  9. Generating units performances: power system requirements

    Energy Technology Data Exchange (ETDEWEB)

    Fourment, C; Girard, N; Lefebvre, H

    1994-08-01

    The part of generating units within the power system is more than providing power and energy. Their performance are not only measured by their energy efficiency and availability. Namely, there is a strong interaction between the generating units and the power system. The units are essential components of the system: for a given load profile the frequency variation follows directly from the behaviour of the units and their ability to adapt their power output. In the same way, the voltage at the units terminals are the key points to which the voltage profile at each node of the network is linked through the active and especially the reactive power flows. Therefore, the customer will experience the frequency and voltage variations induced by the units behaviour. Moreover, in case of adverse conditions, if the units do not operate as well as expected or trip, a portion of the system, may be the whole system, may collapse. The limitation of the performance of a unit has two kinds of consequences. Firstly, it may result in an increased amount of not supplied energy or loss of load probability: for example if the primary reserve is not sufficient, a generator tripping may lead to an abnormal frequency deviation, and load may have to be shed to restore the balance. Secondly, the limitation of a unit performance results in an economic over-cost for the system: for instance, if not enough `cheap` units are able to load-following, other units with higher operating costs have to be started up. We would like to stress the interest for the operators and design teams of the units on the one hand, and the operators and design teams of the system on the other hand, of dialog and information exchange, in operation but also at the conception stage, in order to find a satisfactory compromise between the system requirements and the consequences for the generating units. (authors). 11 refs., 4 figs.

  10. Racial Conflict in the United States: What Should Be Done? Grade Twelve. [Resource Unit V.] Project Social Studies.

    Science.gov (United States)

    Minnesota Univ., Minneapolis. Project Social Studies Curriculum Center.

    This is the fifth of seven resource units for a twelfth grade course on value conflicts and policy decisions. The topic for this unit is racial conflict in the United States. The introduction explains how this unit coincides with other units of the K-12 series which have treated intergroup relations. The objectives are listed as to…

  11. Dependence of the paired motor unit analysis on motor unit discharge characteristics in the human tibialis anterior muscle

    Science.gov (United States)

    Stephenson, Jennifer L.; Maluf, Katrina S.

    2011-01-01

    The paired motor unit analysis provides in vivo estimates of the magnitude of persistent inward currents (PIC) in human motoneurons by quantifying changes in the firing rate (ΔF) of an earlier recruited (reference) motor unit at the time of recruitment and derecruitment of a later recruited (test) motor unit. This study assessed the variability of ΔF estimates, and quantified the dependence of ΔF on the discharge characteristics of the motor units selected for analysis. ΔF was calculated for 158 pairs of motor units recorded from nine healthy individuals during repeated submaximal contractions of the tibialis anterior muscle. The mean (SD) ΔF was 3.7 (2.5) pps (range −4.2 to 8.9 pps). The median absolute difference in ΔF for the same motor unit pair across trials was 1.8 pps, and the minimal detectable change in ΔF required to exceed measurement error was 4.8 pps. ΔF was positively related to the amount of discharge rate modulation in the reference motor unit (r2=0.335; Precruitment of the reference and test motor units (r2=0.229, Pmotor unit activity (r2=0.110, Precruitment threshold of the test motor unit (r2=0.237, Pmotor unit analysis. PMID:21459110

  12. Units Based on Constants: The Redefinition of the International System of Units

    Science.gov (United States)

    Stenger, J.; Ullrich, J. H.

    2016-03-01

    Recent decisions of the General Conference on Weights and Measures of the Metre Convention have opened the door to a fundamental change of the International System of Units, the SI, in 2018. The revised SI will be based on fixing the numerical values of seven defining constants corresponding to the seven traditional base units. This will bring about basic modifications in the definition of the kilogram, the ampere, the kelvin, and the mole and will have consequences for units derived from them. In contrast, the second, the meter, and the candela will not be affected. This paper describes the motivation and rationale behind this endeavor, introduces the new definitions, and reviews the requirements for the redefinitions as well as the status of the experiments that are currently being carried out to fulfill them. Benefits and a wide-reaching impact for the realization and dissemination of the units are anticipated because innovative technologies with ever-increasing accuracy will emerge, enabling the direct realization over widespread measurement ranges without the definitions themselves having to be changed.

  13. Solution for backfitting of a controlled atmosphere area in radiopharmaceuticals unit: the mobile unit of decontamination; Solution pour la mise en conformite d'une zone d'atmosphere controlee en unite de radiopharmacie: l'unite mobile de decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, H.; Desruet, M.D. [Radiopharmacie, CHU de Grenoble, (France); Gallazzini-Crepin, C.; Calizzano, A.; Bourre, J.C. [clinique universitaire de medecine nucleaire, CHU de Grenoble, (France); Skalli, S.; Foroni, L. [pole de pharmacie, CHU de Grenoble, (France); Fagret, D. [clinique universitaire de medecine nucleaire, CHU de Grenoble, (France)

    2009-05-15

    The laboratory of radiopharmaceuticals preparation is a controlled area, defined by good practices of preparation. In order to answer to this regulatory requirement, the environment follow-up is made regularly by the hygiene service of the Grenoble University hospital center (C.H.U.). The results of the last sampling turned out to be wrong. Our objective are to remedy this air contamination and to improve the particulate air quality. A mobile unit of air cleaning allowed to be in accordance with the law at the air cleanliness level for the area of radiopharmaceuticals preparation at the Grenoble C.H.U.. It allows to answer to exigence of good practices of preparation face to the controlled atmosphere areas, in a rapid way, efficient way and cheap way, especially before the reorganization of radiopharmacy place. (N.C.)

  14. Case law: Canada, France, Switzerland, United States

    International Nuclear Information System (INIS)

    Anon.

    2012-01-01

    Canada: Appellate decision upholding nuclear regulatory licensing process and practices for consultation with aboriginal groups: Fond du Lac Denesuline First Nation v. Canada (Attorney General). France: Court of Appeal of Nimes regarding the SOCATRI incident in July 2008; Conseil d'Etat regarding the association Reseau 'Sortir du nucleaire'. Switzerland: Judgement of the Federal Administrative Court in the matter of Balmer-Schafroth a.o.v. BKW FMB Energy Ltd on the repeal of the time limitation with respect to the operating licence for the Muehleberg nuclear power plant. United States: Judgement of a US District Court granting a permanent injunction against the State of Vermont in order to prevent certain State laws from prohibiting Vermont Yankee nuclear power plant's continued operation

  15. Generating Units

    Data.gov (United States)

    Department of Homeland Security — Generating Units are any combination of physically connected generators, reactors, boilers, combustion turbines, and other prime movers operated together to produce...

  16. Intelligent multi-unit disk controller

    International Nuclear Information System (INIS)

    Poirot, Lucien

    1982-01-01

    This controller has been designed as a link between a 16 bits minicomputer and two types of disks units interface: the SMD interface and an equivalent to the DRI unit interface. Four units of each type can be handled by the controller. A bit slice microprocessor controls the interface with the disks units. The maximum exchange rate is 8 megabits per second. A CRC feature has been provided for error detection. A 16 bits microprocessor implements the interface to the computer, assuring head positioning, the management of bad tracks, as well as the supervision of each transfer. A internal buffer memory allows an asynchronous dialogue with the computer. The implementation of the controller makes easy the adaptation to disks units of various types, and though it has been initially intended for a minicomputer of the MITRA type, its microprocessor based design makes it fitted to any minicomputer. (author) [fr

  17. Final Environmental Statement related to the operation of Beaver Valley Power Station, Unit 2 (Docket No. 50-412)

    International Nuclear Information System (INIS)

    1985-09-01

    This Final Environmental Statement contains the second assessment of the environmental impact associated with Beaver Valley Power Station Unit 2 pursuant to the National Environmental Policy Act of 1969 (NEPA) and Title 10 of the Code of Federal Regulations, Part 51, as amended, of the Nuclear Regulatory Commission regulations. This statement examines the environment, environmental consequences and mitigating actions, and environmental benefits and costs, and concludes that the action called for is the issuance of an operating license for Beaver Valley Unit 2

  18. Opportunities and Barriers to Resource Recovery and Recycling from Shredder Residue in the United States

    Science.gov (United States)

    Nayak, Naren; Apelian, Diran

    2014-11-01

    Shredder residue is the by-product remaining after ferrous and nonferrous metals have been recovered from the processing of vehicles, white goods, and peddler scrap. Shredder residue consists of glass, plastics, rubber, dirt, and small amounts of metal. It is estimated that 5-7 million tons of this shredder residue are landfilled each year in the United States. Technical advancements, coupled with European Union directives and the economic climate, have transformed the recycling of shredder residue in Europe. In the United States, however, regulatory controls and the cheap cost of landfill have worked against the advancement of recycling and recovery of this resource. The Argonne National Laboratory, which is funded by the U.S. Department of Energy, has investigated the effectiveness of recycling shredder residue into polymers. Other research has examined the use of shredder residue in waste-to-energy applications. To improve our ability to process and recycle shredder residue, an investigation of the regulatory, economic, and technological challenges was undertaken. The objective was to conduct a comprehensive review of work done to date, to document the composition of typical shredder output and to identify potential recoverable items (residual metals, plastics, rubber, foam, etc.). Along with uncovering potential new markets, the research would identify the technical, regulatory, and economic barriers to developing those markets.

  19. The United Kingdom: Issues for the United States

    National Research Council Canada - National Science Library

    Archick, Kristin

    2007-01-01

    ...; and more recently, from the UK's strong support in countering terrorism and confronting Iraq. The United States and Britain also share a mutually beneficial trade and economic relationship, and are each other's biggest foreign direct investors...

  20. A real-time material control concept for safeguarding special nuclear material in United States licensed processing facilities

    International Nuclear Information System (INIS)

    Shea, T.E.

    1976-01-01

    This paper describes general safeguards research being undertaken by the United States Nuclear Regulatory Commission. Efforts to improve the ability of United States licensed plants to contend with the perceived threat of covert material theft are emphasized. The framework for this improvement is to break down the internal control and accounting system into subsystems to achieve material isolation, inventory control, inventory characterization, and inventory containment analysis. A general programme is outlined to develop and evaluate appropriate mechanisms, integrate selected mechanisms into subsystems, and evaluate the subsystems in the context of policy requirements. (author)

  1. Measurement units of physical values; Unites de mesure des grandeurs physiques

    Energy Technology Data Exchange (ETDEWEB)

    Debraine, P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1955-07-01

    The aim of this paper is twofold: 1) to give an analysis of the formation conditions of the various systems of units, 2) to show how the practical problems involving changes of units can be solved. This analysis leads to the conception of 'types' of systems, which is very useful to clarity the question of rationalized and non rationalized systems. The second point which consists essentially in: 1) finding the relationship between the measures of a given quantity in different systems, 2) deriving practical formulas, 3) deriving formulas in various 'types' of systems, is made easier by use of sets of: * definition formulas, * transformation formulas, * units of the various practical systems with useful numerical information covering the following fields: ** geometry, ** kinematics, ** mechanics, ** electricity and magnetism, ** thermodynamics, ** radiation, ** photometry, These sets being printed on coloured paper can be easily found. A number of numerical examples (21) show in a detailed way how to solve the various problems likely to occur. A chapter is particularly devoted to the Giorgi MKS system. (author) [French] Le but de cet expose est double: 1) donner une analyse des conditions de formation des differents systemes d'unites, 2) montrer comment peuvent se resoudre les problemes pratiques de changement d'unites. Cette analyse amene a 1a conception de ''types'' de systemes, conception tres utile pour eclairer la question des systemes rationalises et non rationalises. La seconde partie du programme qui consiste essentiellement: 1) a determiner les relations entre les mesures d'une meme grandeur dans differents systemes, 2) a etablir des formules pratiques, 3) a etablir les formules valables dans un ''type'' de systeme donne est facilitee par l'utilisation de listes classees de 1) formules de definition, 2) equations de transformation, 3) unites des differents systemes accompagnees de relations numeriques utiles, couvrant les domaines suivants: 1) geometrie, 5

  2. The management of household hazardous waste in the United Kingdom.

    Science.gov (United States)

    Slack, R J; Gronow, J R; Voulvoulis, N

    2009-01-01

    Waste legislation in the United Kingdom (UK) implements European Union (EU) Directives and Regulations. However, the term used to refer to hazardous waste generated in household or municipal situations, household hazardous waste (HHW), does not occur in UK, or EU, legislation. The EU's Hazardous Waste Directive and European Waste Catalogue are the principal legislation influencing HHW, although the waste categories described are difficult to interpret. Other legislation also have impacts on HHW definition and disposal, some of which will alter current HHW disposal practices, leading to a variety of potential consequences. This paper discusses the issues affecting the management of HHW in the UK, including the apparent absence of a HHW-specific regulatory structure. Policy and regulatory measures that influence HHW management before disposal and after disposal are considered, with particular emphasis placed on disposal to landfill.

  3. Technical Specifications, Comanche Peak Steam Electric Station, Unit 1 (Docket No. 50-445)

    International Nuclear Information System (INIS)

    1990-04-01

    The Technical Specifications for Comanche Peak Steam Electric Station, Unit 1 were prepared by the US Nuclear Regulatory Commission. They set forth the limits, operating conditions, and other requirements applicable to a nuclear reactor facility, as set forth in Section 50.36 of Title 10 of the Code of Federal Regulations Part 50, for the protection of the health and safety of the public

  4. Anti-Terrorism Authority Under the Laws of the United Kingdom and the United States

    National Research Council Canada - National Science Library

    Feikert, Clare; Doyle, Charles

    2006-01-01

    This is a comparison of the laws of the United Kingdom and of the United States that govern criminal and intelligence investigations of terrorist activities Both systems rely upon a series of statutory authorizations...

  5. Use of Internet Search Data to Monitor Rotavirus Vaccine Impact in the United States, United Kingdom, and Mexico.

    Science.gov (United States)

    Shah, Minesh P; Lopman, Benjamin A; Tate, Jacqueline E; Harris, John; Esparza-Aguilar, Marcelino; Sanchez-Uribe, Edgar; Richardson, Vesta; Steiner, Claudia A; Parashar, Umesh D

    2018-02-19

    Previous studies have found a strong correlation between internet search and public health surveillance data. Less is known about how search data respond to public health interventions, such as vaccination, and the consistency of responses in different countries. In this study, we aimed to study the correlation between internet searches for "rotavirus" and rotavirus disease activity in the United States, United Kingdom, and Mexico before and after introduction of rotavirus vaccine. We compared time series of internet searches for "rotavirus" from Google Trends with rotavirus laboratory reports from the United States and United Kingdom and with hospitalizations for acute gastroenteritis in the United States and Mexico. Using time and location parameters, Google quantifies an internet query share (IQS) to measure the relative search volume for specific terms. We analyzed the correlation between IQS and laboratory and hospitalization data before and after national vaccine introductions. There was a strong positive correlation between the rotavirus IQS and laboratory reports in the United States (R2 = 0.79) and United Kingdom (R2 = 0.60) and between the rotavirus IQS and acute gastroenteritis hospitalizations in the United States (R2 = 0.87) and Mexico (R2 = 0.69) (P United States and by 70% (95% CI, 55%-86%) in Mexico. In the United Kingdom, there was a loss of seasonal variation after vaccine introduction. Rotavirus internet search data trends mirrored national rotavirus laboratory trends in the United States and United Kingdom and gastroenteritis-hospitalization data in the United States and Mexico; lower correlations were found after rotavirus vaccine introduction. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  6. United States Nuclear Regulatory Commission staff practice and procedure digest

    International Nuclear Information System (INIS)

    1990-03-01

    This document contains procedures for review by US Nuclear Regulatory Commission for reviewing and deciding on matters pertaining to nuclear power plant licensing. Also, contained within the document are decisions the Commission has made between July 1972 to September 1989. (F.S.D.)

  7. Safety Evaluation Report related to the operation of LaSalle County Station, Units 1 and 2. Docket Nos. 50-373 and 50-374

    International Nuclear Information System (INIS)

    1984-03-01

    This supplement to the Safety Evaluation Report of Commonwealth Edison Company's application for a license to operate its La Salle County Station, Unit 2, located in Brookfield Township, La Salle County, Illinois, has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. This supplement is to update evaluations on Unit 2 issues identified in the previous Safety Evaluation Report and Supplements that need resolution prior to issuance of the full power operating license for Unit 2

  8. United Nations Peacekeeping: Issues for Congress

    National Research Council Canada - National Science Library

    Browne, Marjorie A

    2008-01-01

    A major issue facing the United Nations, the United States, and the 110th Congress is the extent to which the United Nations has the capacity to restore or keep the peace in the changing world environment...

  9. United Nations Peacekeeping: Issues for Congress

    National Research Council Canada - National Science Library

    Browne, Marjorie A

    2007-01-01

    A major issue facing the United Nations, the United States, and the 110th Congress is the extent to which the United Nations has the capacity to restore or keep the peace in the changing world environment...

  10. Qualification of package units; Qualifizierung von Package Units

    Energy Technology Data Exchange (ETDEWEB)

    Brombacher, M.; Walter, U. [Bayer AG, Leverkusen (Germany)

    1999-07-01

    The use of package units in pharmaceutical plants is increasing. If they are involved in the manufacture of pharmaceuticals and have an influence on the quality of the end product, the user is required to validate the processes used. Parallel to the growing demands with respect to the automation of these units, the importance of PCS equipment has increased and with this the necessity for its qualification. Experience to date shows that the manufacturer's awareness of these requirements can be heightened still further. This paper describes approaches for improving the present situation and should be interpreted not as criticism but as providing an opportunity to increase the knowledge base and work together to define solutions which satisfy the guidelines. (orig.) [German] Der Einsatz von Package Units in Pharma-Anlagen erfaehrt zunehmende Verbreitung. Wenn sie an der Herstellung von Arzneimitteln beteiligt sind und auf die Qualitaet des Endprodukts Einfluss nehmen, unterliegen sie der Validierungspflicht, die der Anwender zu gewaehrleisten hat. Entsprechend den wachsenden Anforderungen an die Automatisierung dieser Einheiten ist auch der Stellenwert der PLT-Ausruestung angestiegen und mit ihm die Notwendigkeit von deren Qualifizierung. Die bisherige Praxis zeigt, dass die Sensbilitaet der Hersteller diesen Anforderungen gegenueber noch besser entwickelt werden kann. Der Beitrag zeigt Wege auf, um die derzeitige Situation zu verbessern und sollte nicht als Kritik sondern als Chance aufgefasst werden, den Wissensstand auszugleichen und gemeinsam zu richtliniengerechten Loesungen zu kommen. (orig.)

  11. Equilibrium Selection with Risk Dominance in a Multiple-unit Unit Uniform Price Auction

    DEFF Research Database (Denmark)

    Boom, Anette

    This paper uses an adapted version of the linear tracing procedure, suggested by Harsanyi and Selten (1988), in order to discriminate between two types of multiple Nash equilibria. Equilibria of the same type are pay-off equivalent in the analysed multiple-unit unit price auction where two seller...

  12. Neighbors United for Health

    Science.gov (United States)

    Westhoff, Wayne W.; Corvin, Jaime; Virella, Irmarie

    2009-01-01

    Modeled upon the ecclesiastic community group concept of Latin America to unite and strengthen the bond between the Church and neighborhoods, a community-based organization created Vecinos Unidos por la Salud (Neighbors United for Health) to bring health messages into urban Latino neighborhoods. The model is based on five tenants, and incorporates…

  13. Smart Rocking Armour Units

    NARCIS (Netherlands)

    Hofland, B.; Arefin, Syed Shamsil; van der Lem, Cock; van gent, Marcel

    2018-01-01

    This paper describes a method to measure the rocking motion of lab-scale armour units. Sensors as found in mobile phones are used. These sensors, data-storage and battery are all embedded in the model units, such that they can be applied without wires attached to them. The technique is applied to

  14. The instrument control unit of SPICA SAFARI: a macro-unit to host all the digital control functionalities of the spectrometer

    Science.gov (United States)

    Di Giorgio, Anna Maria; Biondi, David; Saggin, Bortolino; Shatalina, Irina; Viterbini, Maurizio; Giusi, Giovanni; Liu, Scige J.; Cerulli-Irelli, Paquale; Van Loon, Dennis; Cara, Christophe

    2012-09-01

    We present the preliminary design of the Instrument Control Unit (ICU) of the SpicA FAR infrared Instrument (SAFARI), an imaging Fourier Transform Spectrometer (FTS) designed to give continuous wavelength coverage in both photometric and spectroscopic modes from around 34 to 210 µm. Due to the stringent requirements in terms of mass and volume, the overall SAFARI warm electronics will be composed by only two main units: Detector Control Unit and ICU. ICU is therefore a macro-unit incorporating the four digital sub-units dedicated to the control of the overall instrument functionalities: the Cooler Control Unit, the Mechanism Control Unit, the Digital processing Unit and the Power Supply Unit. Both the mechanical solution adopted to host the four sub-units and the internal electrical architecture are presented as well as the adopted redundancy approach.

  15. Inching toward incrementalism: federalism, devolution, and health policy in the United States and the United Kingdom.

    Science.gov (United States)

    Sparer, Michael S; France, George; Clinton, Chelsea

    2011-02-01

    In the United States, the recently enacted Patient Protection and Affordable Care Act of 2010 envisions a significant increase in federal oversight over the nation's health care system. At the same time, however, the legislation requires the states to play key roles in every aspect of the reform agenda (such as expanding Medicaid programs, creating insurance exchanges, and working with providers on delivery system reforms). The complicated intergovernmental partnerships that govern the nation's fragmented and decentralized system are likely to continue, albeit with greater federal oversight and control. But what about intergovernmental relations in the United Kingdom? What impact did the formal devolution of power in 1999 to Scotland, Wales, and Northern Ireland have on health policy in those nations, and in the United Kingdom more generally? Has devolution begun a political process in which health policy in the United Kingdom will, over time, become increasingly decentralized and fragmented, or will this "state of unions" retain its long-standing reputation as perhaps the most centralized of the European nations? In this article, we explore the federalist and intergovernmental implications of recent reforms in the United States and the United Kingdom, and we put forward the argument that political fragmentation (long-standing in the United States and just emerging in the United Kingdom) produces new intergovernmental partnerships that, in turn, produce incremental growth in overall government involvement in the health care arena. This is the impact of what can be called catalytic federalism.

  16. Fatigue in Breakwater Concrete Armour Units

    DEFF Research Database (Denmark)

    Burcharth, Hans F.

    The reliability of rubble mound breakwaters depends on the hydraulic stability and the mechanical strength of the armour units. The paper deals with the important aspect of fatigue related to the strength of concrete armour units.......The reliability of rubble mound breakwaters depends on the hydraulic stability and the mechanical strength of the armour units. The paper deals with the important aspect of fatigue related to the strength of concrete armour units....

  17. The transition to competency-based pediatric training in the United Arab Emirates.

    Science.gov (United States)

    Ibrahim, Halah; Al Tatari, Hossam; Holmboe, Eric S

    2015-04-01

    Although competency-based medical education has become the standard for physician training in the West, many developing countries have not yet adopted competency-based training. In 2009 in the United Arab Emirates, the government regulatory and operational authorities for healthcare in Abu Dhabi mandated a wide-scale reform of the emirate's postgraduate residency programs to the competency-based framework of the newly formed Accreditation Council for Graduate Medical Education-International (ACGME-I). This article briefly describes the rationale for competency-based medical education and provides an overview of the transition from traditional, time-based residency training to competency-based postgraduate medical education for the Pediatrics residency programs in Abu Dhabi. We will provide data on the initial impact of this transition on resident performance and patient outcomes in a Pediatrics residency program in an academic medical center in the United Arab Emirates.

  18. Mobile units to hydro geochemistry characterization

    International Nuclear Information System (INIS)

    Gomez, P.; Martinez, B.; Turrero, M.J.

    1994-01-01

    This report shows the mobile units for hydro geochemical studies. The authors analyze the work of mobile unit and the cars that conform the unit: Sampling car and analysis car: The sampling and equipment are took into account as well

  19. 7 CFR 1215.20 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1215.20 Section 1215.20 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... United States. United States means all of the States. Popcorn Board ...

  20. UNIT COMMITMENT: A NEW TRUNCATED METHOD OF UNIT ...

    African Journals Online (AJOL)

    NIJOTECH

    Data obtained from the National Electric Power Authority (NEPA) has been used to test the efficacy of this approach. ... every unit in the system must be respected. Some of these ..... Analysis of Power System Reliability. 2.Edwin K. W, Machat, ...

  1. Organization of Control Units with Operational Addressing

    OpenAIRE

    Alexander A. Barkalov; Roman M. Babakov; Larysa A. Titarenko

    2012-01-01

    The using of operational addressing unit as the block of control unit is proposed. The new structure model of Moore finite-state machine with reduced hardware amount is developed. The generalized structure of operational addressing unit is suggested. An example of synthesis process for Moore finite-state machine with operational addressing unit is given. The analytical researches of proposed structure of control unit are executed.

  2. End of FY10 report - used fuel disposition technical bases and lessons learned : legal and regulatory framework for high-level waste disposition in the United States.

    Energy Technology Data Exchange (ETDEWEB)

    Weiner, Ruth F.; Blink, James A. (Lawrence Livermore National Laboratory, Livermore, CA); Rechard, Robert Paul; Perry, Frank (Los Alamos National Laboratory, Los Alamos, NM); Jenkins-Smith, Hank C. (University of Oklahoma, Norman, OK); Carter, Joe (Savannah River Nuclear Solutions, Aiken, SC); Nutt, Mark (Argonne National Laboratory, Argonne, IL); Cotton, Tom (Complex Systems Group, Washington DC)

    2010-09-01

    This report examines the current policy, legal, and regulatory framework pertaining to used nuclear fuel and high level waste management in the United States. The goal is to identify potential changes that if made could add flexibility and possibly improve the chances of successfully implementing technical aspects of a nuclear waste policy. Experience suggests that the regulatory framework should be established prior to initiating future repository development. Concerning specifics of the regulatory framework, reasonable expectation as the standard of proof was successfully implemented and could be retained in the future; yet, the current classification system for radioactive waste, including hazardous constituents, warrants reexamination. Whether or not consideration of multiple sites are considered simultaneously in the future, inclusion of mechanisms such as deliberate use of performance assessment to manage site characterization would be wise. Because of experience gained here and abroad, diversity of geologic media is not particularly necessary as a criterion in site selection guidelines for multiple sites. Stepwise development of the repository program that includes flexibility also warrants serious consideration. Furthermore, integration of the waste management system from storage, transportation, and disposition, should be examined and would be facilitated by integration of the legal and regulatory framework. Finally, in order to enhance acceptability of future repository development, the national policy should be cognizant of those policy and technical attributes that enhance initial acceptance, and those policy and technical attributes that maintain and broaden credibility.

  3. 7 CFR 1280.127 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1280.127 Section 1280.127 Agriculture... INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.127 United States. United States means collectively the 50 States and the District of Columbia. ...

  4. 76 FR 66333 - Carolina Power & Light Company, H.B. Robinson Steam Electric Plant, Unit No. 2; Environmental...

    Science.gov (United States)

    2011-10-26

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-261; NRC-2011-0247] Carolina Power & Light Company, H.B. Robinson Steam Electric Plant, Unit No. 2; Environmental Assessment and Finding of No Significant... Facility Operating License No. DPR-23, issued to Carolina Power & Light Company (the licensee), for...

  5. A Point Source of a Different Color: Identifying a Gap in United States Regulatory Policy for “Green” CSO Treatment Using Constructed Wetlands

    Directory of Open Access Journals (Sweden)

    Zeno F. Levy

    2014-04-01

    Full Text Available Up to 850 billion gallons of untreated combined sewer overflow (CSO is discharged into waters of the United States each year. Recent changes in CSO management policy support green infrastructure (GI technologies as “front of the pipe” approaches to discharge mitigation by detention/reduction of urban stormwater runoff. Constructed wetlands for CSO treatment have been considered among suites of GI solutions. However, these wetlands differ fundamentally from other GI technologies in that they are “end of the pipe” treatment systems that discharge from a point source, and are therefore regulated in the U.S. under the National Pollution Discharge Elimination System (NPDES. We use a comparative regulatory analysis to examine the U.S. policy framework for CSO treatment wetlands. We find in all cases that permitting authorities have used best professional judgment to determine effluent limits and compliance monitoring requirements, referencing technology and water quality-based standards originally developed for traditional “grey” treatment systems. A qualitative comparison with Europe shows less stringent regulatory requirements, perhaps due to institutionalized design parameters. We recommend that permitting authorities develop technical guidance documents for evaluation of “green” CSO treatment systems that account for their unique operational concerns and benefits with respect to sustainable development.

  6. The use of irradiated food for immunosuppressed hospital patients in the United Kingdom

    International Nuclear Information System (INIS)

    Pryke, D.C.; Taylor, R.R.

    1995-01-01

    Irradiation has been recommended as a method for preparing foods for hospital patients requiring sterile diets as a result of intensive therapy or disease that has resulted in suppression of the immune system. It has a number of advantages over other methods and in recognition of this, in the United Kingdom, the use of irradiated foods for hospital patients has been specifically exempted from regulatory control. Due to a number of factors there is a move away from keeping patients in a sterile environment; however, irradiation may still have a role to play for vulnerable and high-risk patients. This paper summarizes the use of radiation-sterilized foods in hospitals in the United Kingdom and discusses the future potential for both radiation-sterilized and ‘radiation-pasturized’ foods

  7. Barriers to the implementation of green chemistry in the United States.

    Science.gov (United States)

    Matus, Kira J M; Clark, William C; Anastas, Paul T; Zimmerman, Julie B

    2012-10-16

    This paper investigates the conditions under which firms are able to develop and implement innovations with sustainable development benefits. In particular, we examine "green chemistry" innovations in the United States. Via interviews with green chemistry leaders from industry, academia, nongovernmental institutions (NGOs), and government, we identified six major categories of challenges commonly confronted by innovators: (1) economic and financial, (2) regulatory, (3) technical, (4) organizational, (5) cultural, and (6) definition and metrics. Further analysis of these barriers shows that in the United States, two elements of these that are particular to the implementation of green chemistry innovations are the absence of clear definitions and metrics for use by researchers and decision makers, as well as the interdisciplinary demands of these innovations on researchers and management. Finally, we conclude with some of the strategies that have been successful thus far in overcoming these barriers, and the types of policies which could have positive impacts moving forward.

  8. Unit Manning

    National Research Council Canada - National Science Library

    McGinniss, Mike

    2003-01-01

    .... This decision combines two crucial initiatives: first, transforming the Army from an individual soldier replacement system to a unit manning system that enhances cohesion and keeps trained soldiers, leaders, and commanders together longer, thereby...

  9. Safety Evaluation Report related to the operation of Comanche Peak Steam Electric Station, Unit 2 (Docket No. 50-446)

    International Nuclear Information System (INIS)

    1992-09-01

    This document supplement 25 to the Safety Evaluation Report related to the operation of the Comanche Peak Steam Electric Station (CPSES), Unit 2 (NUREG-0797), has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission (NRC). The facility is located in Somervell County, Texas, approximately 40 miles southwest of Fort Worth, Texas. This supplement reports the status of certain issues that had not been resolved when the Safety Evaluation Report and Supplements 1, 2, 3, 4, 6, 12, 21, 22, 23, and 24 to that report were published. This supplement deals primarily with Unit 2 issues; however, it also references evaluations for several Unit 1 licensing items resolved since Supplement 24 was issued

  10. Ecological units: definitions and application.

    Science.gov (United States)

    Jax, Kurt

    2006-09-01

    Concepts of ecological units, such as population, community, and ecosystem, are at the basis of ecological theory and research and have increasingly become the focus of conservation strategies. Concepts of these units still suffer from inconsistencies and confusions over terminology. The different concepts are treated here together as a common "conceptual cluster," with similar ecological functions (roles) and similar problems in their definition and use. An analysis of the multitude of existing terms and concepts that have been developed for these units reveals that they differ with respect to at least four basic criteria: (i) the questions as to whether they are defined statistically or via a network of interactions; (ii) if their boundaries are drawn by topographical or process-related criteria; (iii) how high the required internal relationships are; and (iv) if they are perceived as "real" entities or abstractions by an observer The various definitions cannot be easily sorted into just a few types, but they can be characterized by several independent criteria. I argue that serious problems arise if the different possibilities of defining ecological units are not recognized and if the concepts are perceived as self-evident. The different concepts of ecological units should be defined and used in a philosophically informed manner I propose a dual approach to the use of ecological units. Generic meanings of the main concepts (especially population, community, and ecosystem) should be retained only as heuristically useful perspectives, while specific and "operational" definitions of the concepts as units should be developed, depending on specific purposes of their use. Some thoughts on the basic requirements for such definitions and the domains of their uses are briefly explained.

  11. Regulating mobile advertising in the European Union and the United States

    DEFF Research Database (Denmark)

    Cleff, Evelyne Beatrix

    2008-01-01

    Mobile advertising is a gradually developing component of the marketing mix that includes advertisements directed to or accessed on consumers' mobile devices. Growing concerns about the protection of the consumers' personal data are being raised since mobile advertising may become an extremely...... intrusive practice in an intimate personal space. Approaches of protecting the consumers' personal information differ greatly throughout the world. This article contrasts the regulatory environment in the European Union and in the United States applicable to the consumer's privacy and personal data used...

  12. 7 CFR 1260.108 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1260.108 Section 1260.108 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... Promotion and Research Order Definitions § 1260.108 United States. United States means the 50 States and the...

  13. 7 CFR 1221.32 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1221.32 Section 1221.32 Agriculture... INFORMATION ORDER Sorghum Promotion, Research, and Information Order Definitions § 1221.32 United States. United States or U.S. means collectively the 50 States, the District of Columbia, the Commonwealth of...

  14. 7 CFR 1216.30 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1216.30 Section 1216.30 Agriculture... INFORMATION ORDER Peanut Promotion, Research, and Information Order Definitions § 1216.30 United States. United States means collectively the 50 states, the District of Columbia, the Commonwealth of Puerto Rico...

  15. 7 CFR 1218.22 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1218.22 Section 1218.22 Agriculture... INFORMATION ORDER Blueberry Promotion, Research, and Information Order Definitions § 1218.22 United States. United States means collectively the 50 states, the District of Columbia, the Commonwealth of Puerto Rico...

  16. United States Department of Energy/United States Environmental Protection Agency beneficial uses program for the use of cesium-137

    International Nuclear Information System (INIS)

    Krenz, D.L.; McMullen, W.H.; Yeager, J.G.; Sivinski, J.S.

    1982-03-01

    The goal of the United States Department of Energy (US DOE) Beneficial Uses Program for use of Cesium-137 is to identify and develop ways in which this isotope can be utilized to aid in the solution of major national and international problems. Gamma radiation from Cesium-137 has been shown to be effective in reducing pathogens in sewage sludge to levels where reuse of the material in public areas meets current regulatory criteria for safety. The first full-scale demonstration of this technology is being actively pursued in Albuquerque, New Mexico. Similar gamma treatment has also proved effective in ridding food commodities of destructive insects. This paper discusses program research and engineering history related to sludge irradiation, current activities and future plans for sludge irradiation and plans regarding food irradiation

  17. [Aftercare for durability and profitability of single-unit and multi-unit fixed dental prostheses

    NARCIS (Netherlands)

    Baat, C. de; Loveren, C. van; Maarel-Wierink, C.D. van der; Witter, D.J.; Creugers, N.H.J.

    2013-01-01

    An important aim ofa treatment with single-unit and multi-unit fixed dental prostheses is a durable and profitable treatment outcome. That requires aftercare, too. First, the frequency of routine oral examinations should be assessed, using an individual risk profile. The objectives of the routine

  18. Organisation and experience of the regulatory review in the United Kingdom

    International Nuclear Information System (INIS)

    Gausden, R.; Woods, P.B.

    1979-01-01

    Regulatory requirements and stages of the review in the UK are outlined. The organisation, management and working procedures of the Inspectorate are described and the effort and timescale which have been found necessary for a satisfactory safety review is discussed. A number of problem areas in the review situation have been identified from experience and these are discussed and possible solutions proposed. They include the importance of early review of generic aspects of systems which are being considered for licensing, the place of safety principles and of detailed engineering assessment in the review process, the independence of the regulatory group's activities in its study of major technical issues and the use which should be made of outside expertise. (auth.)

  19. 24 CFR 970.31 - Replacement units.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Replacement units. 970.31 Section... PUBLIC HOUSING PROGRAM-DEMOLITION OR DISPOSITION OF PUBLIC HOUSING PROJECTS § 970.31 Replacement units. Notwithstanding any other provision of law, replacement public housing units may be built on the original public...

  20. Image processing unit with fall-back.

    NARCIS (Netherlands)

    2011-01-01

    An image processing unit ( 100,200,300 ) for computing a sequence of output images on basis of a sequence of input images, comprises: a motion estimation unit ( 102 ) for computing a motion vector field on basis of the input images; a quality measurement unit ( 104 ) for computing a value of a

  1. 7 CFR 1210.315 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1210.315 Section 1210.315 Agriculture... PLAN Watermelon Research and Promotion Plan Definitions § 1210.315 United States. United States means each of the several States and the District of Columbia. [60 FR 10797, Feb. 28, 1995] National...

  2. 75 FR 53985 - Arizona Public Service Company, et al., Palo Verde Nuclear Generating Station, Unit 3; Temporary...

    Science.gov (United States)

    2010-09-02

    ... NUCLEAR REGULATORY COMMISSION [Docket No. STN 50-530; NRC-2010-0281] Arizona Public Service Company, et al., Palo Verde Nuclear Generating Station, Unit 3; Temporary Exemption 1.0 Background Arizona Public Service Company (APS, the licensee) is the holder of Facility Operating License No. NPF-74, which...

  3. 78 FR 4467 - UniStar Nuclear Energy, Combined License Application for Calvert Cliffs Power Plant, Unit 3...

    Science.gov (United States)

    2013-01-22

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 52-016; NRC-2008-0250] UniStar Nuclear Energy, Combined License Application for Calvert Cliffs Power Plant, Unit 3, Exemption 1.0 Background UniStar Nuclear Energy (UNE), on behalf of Calvert Cliffs Nuclear Project, LLC and UniStar Nuclear Operating Services...

  4. Radix-16 Combined Division and Square Root Unit

    DEFF Research Database (Denmark)

    Nannarelli, Alberto

    2011-01-01

    Division and square root, based on the digitrecurrence algorithm, can be implemented in a combined unit. Several implementations of combined division/square root units have been presented mostly for radices 2 and 4. Here, we present a combined radix-16 unit obtained by overlapping two radix-4...... result digit selection functions, as it is normally done for division only units. The latency of the unit is reduced by retiming and low power methods are applied as well. The proposed unit is compared to a radix-4 combined division/square root unit, and to a radix-16 unit, obtained by cascading two...

  5. Ad valorem versus unit taxes

    DEFF Research Database (Denmark)

    Schröder, Philipp J.H.; Sørensen, Allan

    2010-01-01

    a general equilibrium monopolistic competition model with heterogeneous firms and intra-industry reallocations. We show that the welfare superiority of ad valorem over unit taxes under imperfect competition is not only preserved but amplified. The additional difference between the tools arises because unit...... taxes distort relative prices, which in turn reduces average industry productivity through reallocations (the survival and increased market share of lower productivity firms). Importantly, numerical solutions of the model reveal that the relative welfare loss from using the unit tax increases...

  6. An overview of the activities of the ICRU (International Commission on Radiation Units and Measurements)

    International Nuclear Information System (INIS)

    Wambersie, Andre

    1993-01-01

    The International Commission on Radiation Units and Measurements (ICRU) shares with other International Organizations several common features: easy and privileged access and exchange of information between the different countries and concentration of scientific and medical expertise. Although the ICRU has no legal or regulatory power, it tries to reach a worldwide consensus on quantities and units, on dosimetric procedures, on terminology and concepts etc. This international consensus, together with the improved exchange of information, certainly facilitates the acceptance and the application of the recommendations and thus at the end, will be beneficial for the patient in radiological diagnosis, nuclear medicine and radiation therapy, as well as in radiation protection. (author). 1 appendix

  7. Discovering the impact of preceding units' characteristics on the wait time of cardiac surgery unit from statistic data.

    Directory of Open Access Journals (Sweden)

    Jiming Liu

    Full Text Available INTRODUCTION: Prior research shows that clinical demand and supplier capacity significantly affect the throughput and the wait time within an isolated unit. However, it is doubtful whether characteristics (i.e., demand, capacity, throughput, and wait time of one unit would affect the wait time of subsequent units on the patient flow process. Focusing on cardiac care, this paper aims to examine the impact of characteristics of the catheterization unit (CU on the wait time of cardiac surgery unit (SU. METHODS: This study integrates published data from several sources on characteristics of the CU and SU units in 11 hospitals in Ontario, Canada between 2005 and 2008. It proposes a two-layer wait time model (with each layer representing one unit to examine the impact of CU's characteristics on the wait time of SU and test the hypotheses using the Partial Least Squares-based Structural Equation Modeling analysis tool. RESULTS: Results show that: (i wait time of CU has a direct positive impact on wait time of SU (β = 0.330, p < 0.01; (ii capacity of CU has a direct positive impact on demand of SU (β = 0.644, p < 0.01; (iii within each unit, there exist significant relationships among different characteristics (except for the effect of throughput on wait time in SU. CONCLUSION: Characteristics of CU have direct and indirect impacts on wait time of SU. Specifically, demand and wait time of preceding unit are good predictors for wait time of subsequent units. This suggests that considering such cross-unit effects is necessary when alleviating wait time in a health care system. Further, different patient risk profiles may affect wait time in different ways (e.g., positive or negative effects within SU. This implies that the wait time management should carefully consider the relationship between priority triage and risk stratification, especially for cardiac surgery.

  8. 12 CFR 541.10 - Dwelling unit.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Dwelling unit. 541.10 Section 541.10 Banks and... FEDERAL SAVINGS ASSOCIATIONS § 541.10 Dwelling unit. The term dwelling unit means the unified combination of rooms designed for residential use by one family, other than a single-family dwelling. ...

  9. Progress of the United States foreign research reactor spent nuclear fuel acceptance program

    International Nuclear Information System (INIS)

    Huizenga, D.G.; Clapper, M.; Thrower, A.W.

    2002-01-01

    The United States Department of Energy (DOE), in consultation with the Department of State (DOS), adopted the Nuclear Weapons Nonproliferation Policy Concerning Foreign Research Reactor Spent Nuclear Fuel in May 1996. To date, the Foreign Research Reactor (FRR) Spent Nuclear Fuel (SNF) Acceptance Program has completed 23 shipments. Almost 5000 spent fuel assemblies from eligible research reactors throughout the world have been accepted into the United States under this program. Over the past year, another cross-country shipment of fuel was accomplished, as well as two additional shipments in the fourth quarter of calendar year 2001. These shipments attracted considerable safeguards oversight since they occurred post September 11. Recent guidance from the Nuclear Regulatory Commission (NRC) pertaining to security and safeguards issues deals directly with the transport of nuclear material. Since the Acceptance Program has consistently applied above regulatory safety enhancements in transport of spent nuclear fuel, this guidance did not adversely effect the Program. As the Program draws closer to its termination date, an increased number of requests for program extension are received. Currently, there are no plans to extend the policy beyond its current expiration date; therefore, eligible reactor operators interested in participating in this program are strongly encouraged to evaluate their inventory and plan for future shipments as soon as possible. (author)

  10. Stroke Unit: General principles and standards

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Topçuoğlu

    2015-04-01

    Full Text Available Evidence-based medicinal methods have convincingly shown that stroke unit approach reduces mortality and disability rates, improves the quality of life and economic burden resulting from acute ischemic and hemorrhagic stroke. Any contemporary stroke system of care cannot be successful without putting the stroke unit concept in the center of its organization. Stroke units are the main elements of primary and comprehensive stroke centers. As a modernization process, this article focuses on practical issues and suggestions related to integration of the stroke unit approach to a regionally organized stroke system of care for perusal by not only national health authorities and service providers, but also neurologists. Stroke unit quality metrics revisited herein are of critical importance for hospitals establishing or renovating primary and comprehensive stroke centers.

  11. SPOKEN CUZCO QUECHUA, UNITS 1-6.

    Science.gov (United States)

    SOLA, DONALD F.; AND OTHERS

    THE MATERIALS IN THIS VOLUME COMPRISE SIX UNITS WHICH PRESENT BASIC ASPECTS OF CUZCO QUECHUA PHONOLOGY, MORPHOLOGY, AND SYNTAX FOR THE BEGINNING STUDENT. THE SIX UNITS ARE DESIGNED FOR APPROXIMATELY 120 HOURS OF SUPERVISED CLASS WORK WITH OUTSIDE PREPARATION EXPECTED OF THE STUDENT. EACH UNIT CONSISTS OF A DIALOGUE TO BE MEMORIZED, A DIALOGUE…

  12. United Kingdom and United States Tourism Demand for Malaysia:A Cointegration Analysis

    OpenAIRE

    Habibi, Fateh; Abdul Rahim, Khalid; Chin, Lee

    2008-01-01

    Tourism industry has been an important contributor to the Malaysia economy. In this paper we inspect variations in the long run demand for tourism from United Kingdom and United States to Malaysia. The demand for tourism has been explained by macroeconomic variables, including income in origin countries, tourism prices in Malaysia, and travel cost between the two countries. Annual data from 1972 to 2006 are used for the analysis. Augmented Dickey-Fuller and Johansen’s maximum likelihood tests...

  13. PENGEMBANGAN STRATEGIC BUSINESS UNIT PERHUTANI UNIT III JAWA BARAT DAN BANTEN

    Directory of Open Access Journals (Sweden)

    Rurin Wahyu Listriana

    2014-09-01

    Full Text Available ABSTRACTThis study aimed to 1 analyze the innovation and competitiveness ability of Strategic Business Unit (SBU in the KBM (independent business unit industri and 2 formulate alternative policies that can enhance company innovation and competitiveness. The study was conducted at KBM Industri and SBU within the KBM industri. The information and data was obtained through interviews and distributing questionnaires to 10 respondents. Respondents were chosen based on their expertise and or experience. Data processing techniques used the SWOT analysis and Analytic Hierarchy Process (AHP. Results of this study shows that KBM Industri Unit III have the power and the opportunity to expand, increase growth, and achieve maximum progress by improving the quality, developing new products, improving processes and increasing access to wider market. The potential innovation can also be seen from the process-product innovation, knowledge-skills innovation and method-system innovation. In the KBM Industri Unit III, those potential covers the raw materials, process equipment and products. The improvement of company's innovation was influenced by the main factor organization with the value 0,436 and the most influential factors of marketing with a value 0,398, while the ultimate goal is the improvement of the process with the value 0,756. The improvement of the company's innovation strategy is through strategy priority, namely cooperation with other /external parties weighted by 0,703 and optimizing own capabilities of the research or conducting institutions development research weighted by 0,297.Keywords: SBU, KBM Industri, Innovation, AHP, SWOTABSTRAKPenelitian ini bertujuan 1 menganalisis kemampuan inovasi dan daya saing Strategic Business Unit (SBU di Kesatuan Bisnis Mandiri (KBM Industri dan 2 merumuskan kebijakan alternatif yang dapat meningkatkan inovasi dan daya saing perusahaan. Penelitian  dilakukan pada KBM Industri  dan SBU yang ada didalam  KBM

  14. Development of diagnostic mammography unit

    Energy Technology Data Exchange (ETDEWEB)

    Matsubara, M.; Muraki, T.; Kitade, K. (Toshiba Corp., Kawasaki, Kanagawa (Japan))

    1981-07-01

    The mortality from breast cancer is gradually increasing year after year. Accordingly, it is eagerly desired that X-ray diagnosis information be obtainable with higher accuracy and ease for early detection of the disease. Meeting this demand, development has been made of a 2 x magnification mammography unit (Model MGU-01) capabel of minutely depicting microcalcifications with a size of 150 ..mu..m or thereabout and the peripheral condition of a mammary abscess. The background of the development, the substance of the unit and the examination made of the unit are described here.

  15. Development of diagnostic mammography unit

    International Nuclear Information System (INIS)

    Matsubara, Mitsuyoshi; Muraki, Takeshi; Kitade, Kooichi

    1981-01-01

    The mortality from breast cancer is gradually increasing year after year. Accordingly, it is eagerly desired that X-ray diagnosis information be obtainable with higher accuracy and ease for early detection of the disease. Meeting this demand, development has been made of a 2 x magnification mammography unit (Model MGU-01) capabel of minutely depicting microcalcifications with a size of 150 μm or thereabout and the peripheral condition of a mammary abscess. The background of the development, the substance of the unit and the examination made of the unit are described here. (author)

  16. Design of Dolos Armour Units

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Zhou

    1993-01-01

    The slender, complex types of armour units, such as Tetrapods and Dolosse are widely used. Many of the recent failures are such rubble mound breakwaters revealed that there is an imbalance between strength (structural integrity) of the units and the hydraulic stability (resistance to displacements......) of the armour layers. The paper deals only with dolos armour and presents the first design diagrammes and formulae where stresses from static, quasistatic and impact loads are implemented as well as the hydraulic stability. The dolos is treated as a multi shape unit where the thickness can be adjusted...

  17. Government regulation of forestry practices on private forest land in the United States: an assessment of state government responsibilities and program performance

    Science.gov (United States)

    Paul V. Ellefson; Michael A. Kilgore; James E. Granskog

    2006-01-01

    In 2003, a comprehensive assessment of state government, forest practice regulatory programs in the United States was undertaken. Involved was an extensive review of the literature and information gathering h m program administration in all 50 states. The assessment determined that regulatory programs focus on a wide range of forestry practices applied to private...

  18. Oil Vulnerabilities and United States Strategy

    Science.gov (United States)

    2007-02-08

    Mazda, Mercedes - Benz , Ford, Mercury, and Nissan offer flexible fuel vehicles in the United States. Ethanol is currently produced in the United States...USAWC STRATEGY RESEARCH PROJECT OIL VULNERABILITIES AND UNITED STATES STRATEGY by Colonel Shawn P. Walsh...Colleges and Schools, 3624 Market Street, Philadelphia, PA 19104, (215) 662-5606. The Commission on Higher Education is an institutional accrediting

  19. Vehicle with inclinable caterpillar propulsion units

    International Nuclear Information System (INIS)

    Clar, G.

    1991-01-01

    This vehicle usable in hostile environment such nuclear industry has four propulsion units with a caterpillar track and two integrated motors: one for advancing the caterpillar track and the other for inclining the propulsion unit when overcoming obstacles. Each propulsion unit is easily replaceable because there are no mechanical parts in the body of the vehicle [fr

  20. Discovering the impact of preceding units' characteristics on the wait time of cardiac surgery unit from statistic data.

    Science.gov (United States)

    Liu, Jiming; Tao, Li; Xiao, Bo

    2011-01-01

    Prior research shows that clinical demand and supplier capacity significantly affect the throughput and the wait time within an isolated unit. However, it is doubtful whether characteristics (i.e., demand, capacity, throughput, and wait time) of one unit would affect the wait time of subsequent units on the patient flow process. Focusing on cardiac care, this paper aims to examine the impact of characteristics of the catheterization unit (CU) on the wait time of cardiac surgery unit (SU). This study integrates published data from several sources on characteristics of the CU and SU units in 11 hospitals in Ontario, Canada between 2005 and 2008. It proposes a two-layer wait time model (with each layer representing one unit) to examine the impact of CU's characteristics on the wait time of SU and test the hypotheses using the Partial Least Squares-based Structural Equation Modeling analysis tool. Results show that: (i) wait time of CU has a direct positive impact on wait time of SU (β = 0.330, p relationships among different characteristics (except for the effect of throughput on wait time in SU). Characteristics of CU have direct and indirect impacts on wait time of SU. Specifically, demand and wait time of preceding unit are good predictors for wait time of subsequent units. This suggests that considering such cross-unit effects is necessary when alleviating wait time in a health care system. Further, different patient risk profiles may affect wait time in different ways (e.g., positive or negative effects) within SU. This implies that the wait time management should carefully consider the relationship between priority triage and risk stratification, especially for cardiac surgery.

  1. 75 FR 13606 - Arizona Public Service Company, Palo Verde Nuclear Generating Station, Units 1, 2, and 3...

    Science.gov (United States)

    2010-03-22

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. STN 50-528, STN 50-529, and STN 50-530; NRC-2010-0114] Arizona Public Service Company, Palo Verde Nuclear Generating Station, Units 1, 2, and 3; Environmental...-74, issued to Arizona Public Service Company (APS, the licensee), for operation of the Palo Verde...

  2. The Leapfrog initiative for intensive care unit physician staffing and its impact on intensive care unit performance: a narrative review.

    Science.gov (United States)

    Gasperino, James

    2011-10-01

    The field of critical care has changed markedly in recent years to accommodate a growing population of chronically critically ill patients. New administrative structures have evolved to include divisions, departments, and sections devoted exclusively to the practice of critical care medicine. On an individual level, the ability to manage complex multisystem critical illnesses and to introduce invasive monitoring devices defines the intensivist. On a systems level, critical care services managed by an intensivist-led multidisciplinary team are now recognized by their ability to efficiently utilize hospital resources and improve patient outcomes. Due to the numerous cost and quality issues related to the delivery of critical care medicine, intensive care unit physician staffing (IPS) has become a charged subject in recent years. Although the federal government has played a large role in regulating best practices by physicians, other third parties have entered the arena. Perhaps the most influential of these has been The Leapfrog Group, a consortium representing 130 employers and 65 Fortune 500 companies that purchase health care for their employees. This group has proposed specific regulatory guidelines for IPS that are purported to result in substantial cost containment and improved quality of care. This narrative review examines the impact of The Leapfrog Group's recommendations on critical care delivery in the United States. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. Decisions by regulatory agencies: are they evidence-based?

    Directory of Open Access Journals (Sweden)

    Furberg Curt D

    2007-04-01

    Full Text Available Abstract Contradictory statements about the non-steroidal anti-inflammatory drugs from the European Medicines Agency and the United States Food and Drug Administration have raised questions about whether regulatory decisions are evidence-based. For the selective COX-2 inhibitors, there are clear contraindications and warnings in Europe, but only a vaguely worded Black Box warning in the United States. All the non-selective agents are given an almost "clean bill of health" in Europe, while all of them are judged to have a similar risk-benefit ratio as celecoxib in the United States. The regulatory agencies have failed to recognize the clinical trial evidence that the risk of cardiovascular events varies substantially among the non-selective agents, with diclofenac carrying the highest risk of harm.

  4. Summary data for U.S. commercial nuclear power plants in the United States

    International Nuclear Information System (INIS)

    Heddleson, F.A.

    1978-01-01

    A compilation of data is presented for all United States commercial nuclear power plants for which a construction permit application was made through the Nuclear Regulatory Commission. The data are compiled in four separate tables with cross-referencing indexes: Table 1--General Data; Table 2--Reactor Data; Table 3--Site Data, and Table 4--Circulating-Water System Data. The power plants are listed in numerical order by docket number in all four tables

  5. 31 CFR 596.313 - United States person.

    Science.gov (United States)

    2010-07-01

    ... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY TERRORISM LIST GOVERNMENTS SANCTIONS REGULATIONS General Definitions § 596.313 United States person. The term United States person means any United States...

  6. Critical Concerns for Oral Communication Education in the United States and the United Kingdom

    Science.gov (United States)

    Emanuel, Richard

    2011-01-01

    An examination of oral communication education in the United States (U.S.) and United Kingdom (U.K.) identified four critical concerns: (1) Today's college students are not getting adequate oral communication education; (2) Oral communication education is being relegated to a "module" in another discipline-specific course; (3) When an…

  7. Edexcel A2 Physics Student Unit Guide

    CERN Document Server

    Benn, Mike

    2010-01-01

    Student Unit Guides are perfect for revision. Each guide is written by an examiner and explains the unit requirements, summarises the relevant unit content and includes a series of specimen questions and answers. There are three sections to each guide:. Introduction - includes advice on how to use the guide, an explanation of the skills being tested by the assessment objectives, an outline of the unit or module and, depending on the unit, suggestions for how to revise effectively and prepare for the examination questions. Content Guidance - provides an examiner's overview of the module's key t

  8. AQA A2 Chemistry Student Unit Guide

    CERN Document Server

    Cross, Margaret

    2010-01-01

    Student Unit Guides are perfect for revision. Each guide is written by an examiner and explains the unit requirements, summarises the relevant unit content and includes a series of specimen questions and answers. There are three sections to each guide:. Introduction - includes advice on how to use the guide, an explanation of the skills being tested by the assessment objectives, an outline of the unit or module and, depending on the unit, suggestions for how to revise effectively and prepare for the examination questions. Content Guidance - provides an examiner's overview of the module's key t

  9. Effect of Different Disinfection Protocols on Microbial and Biofilm Contamination of Dental Unit Waterlines in Community Dental Practices

    Directory of Open Access Journals (Sweden)

    Laura Dallolio

    2014-02-01

    Full Text Available Output water from dental unit waterlines (DUWLs may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02% and stabilized chlorine dioxide (0.22%, respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions.

  10. Effect of different disinfection protocols on microbial and biofilm contamination of dental unit waterlines in community dental practices.

    Science.gov (United States)

    Dallolio, Laura; Scuderi, Amalia; Rini, Maria S; Valente, Sabrina; Farruggia, Patrizia; Sabattini, Maria A Bucci; Pasquinelli, Gianandrea; Acacci, Anna; Roncarati, Greta; Leoni, Erica

    2014-02-18

    Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions.

  11. Competent authority approval of package designs in the United Kingdom

    International Nuclear Information System (INIS)

    Morgan-Warren, E.J.

    1999-01-01

    Type B packages and all packages containing fissile material, as well as special form radioactive materials, special arrangements and certain shipments, are required to be approved by the competent authority. In the United Kingdom competent authority approval is carried out on behalf of the Secretary of State by the Radioactive Materials Transport Division (RMTD) of the Department of the Environment, Transport and the Regions (DETR). Competent authority approval of a package design is given only after a detailed assessment of the design by the specialist staff of RMTD. There are three facets to the assessment procedure, namely engineering, criticality and radiation protection, and quality assurance. The engineering assessor ensures that the designer has demonstrated the integrity of the containment and shielding systems under the regulatory conditions. The criticality assessor examines criticality safety and radiation protection measures, and together with the engineering assessor, decides whether this is maintained under regulatory conditions. The quality assurance assessor verifies that the applicant has established the necessary controls to ensure that the design requirements are met. The applicant is responsible for making the case for approval, but the assessment is facilitated if the competent authority is involved with the designer at an early stage in development and during the construction of any test prototype. When a regulatory test programme is required, it is designed and carried out by the applicant, but agreed and witnessed by representatives of RMTD. Following the test programme, the applicant submits a formal application, supported by a design safety report (DSR). The DSR provides a full analysis of the design and the test results, including the behaviour of the package under normal and accident conditions of transport, the manufacturing and maintenance procedures, quality assurance and the emergency provisions for the operation of the package

  12. Nuclear development in the United States

    International Nuclear Information System (INIS)

    Brewer, S.

    1983-01-01

    The history of the nuclear development in the United States has been one of international cooperation relations so far. The United States is to offer the technical information on atomic energy utilization to foreign countries in exchange for the guarantee that they never attempt to have or develop nuclear weapons. Actually, the United States has supplied the technologies on nuclear fuel cycle and other related fields to enable other countries to achieve economical and social progress. The Department of Energy clarified the public promise of the United States regarding the idea of international energy community. The ratio of nuclear power generation to total electric power supply in the United States exceeded 12%, and will exceed 20% by 1990. Since 1978, new nuclear power station has not been ordered, and some of the contracted power stations were canceled. The atomic energy industry in the United States prospered at the beginning of 1970s, but lost the spirit now, mainly due to the institutional problems rather than the technical ones. As the policy of the government to eliminate the obstacles, the improvement of the procedure for the permission and approval, the establishment of waste disposal capability, the verification of fast breeder reactor technology and the promotion of commercial fuel reprocessing were proposed. The re-establishment of the United States as the reliable supplier of atomic energy service is the final aim. (Kako, I.)

  13. Fatigue of Concrete Armour Units

    DEFF Research Database (Denmark)

    Sørensen, N. B.; Burcharth, H. F.; Liu, Z.

    1995-01-01

    In the present article fatigue as a possible reason for failure of Dolosse armour units made of plain concrete is discussed.......In the present article fatigue as a possible reason for failure of Dolosse armour units made of plain concrete is discussed....

  14. Plant Outage Time Savings Provided by Subcritical Physics Testing at Vogtle Unit 2

    International Nuclear Information System (INIS)

    Cupp, Philip; Heibel, M.D.

    2006-01-01

    The most recent core reload design verification physics testing done at Southern Nuclear Company's (SNC) Vogtle Unit 2, performed prior to initial power operations in operating cycle 12, was successfully completed while the reactor was at least 1% ΔK/K subcritical. The testing program used was the first application of the Subcritical Physics Testing (SPT) program developed by the Westinghouse Electric Company LLC. The SPT program centers on the application of the Westinghouse Subcritical Rod Worth Measurement (SRWM) methodology that was developed in cooperation with the Vogtle Reactor Engineering staff. The SRWM methodology received U. S. Nuclear Regulatory Commission (NRC) approval in August of 2005. The first application of the SPT program occurred at Vogtle Unit 2 in October of 2005. The results of the core design verification measurements obtained during the SPT program demonstrated excellent agreement with prediction, demonstrating that the predicted core characteristics were in excellent agreement with the actual operating characteristics of the core. This paper presents an overview of the SPT Program used at Vogtle Unit 2 during operating cycle 12, and a discussion of the critical path outage time savings the SPT program is capable of providing. (authors)

  15. Dedicated education unit: student perspectives.

    Science.gov (United States)

    Nishioka, Vicki M; Coe, Michael T; Hanita, Makoto; Moscato, Susan R

    2014-01-01

    The study compared students' perceptions of their clinical learning experiences in a dedicated education unit (DEU) with their experiences in traditional clinical education. Unlike traditional academic-instructor models, expert nurses in the DEU provide clinical education to students with faculty support. This repeated measures design used student surveys, supplemented by focus group data. Students were more likely to agree that their clinical learning experience was high quality and they had a consistent mentoring relationship during DEU rotations. Students also reported the quality of the unit's learning environment, the leadership style of the nurse manager, and the nursing care on the unit was more favorable in DEUs than traditional units. Consistent with their changed role in DEUs, faculty members were less active in helping students integrate theory and practice. These findings provide additional evidence of the value that the DEU model contributes to high-quality clinical education.

  16. Practical unit testing with JUnit and Mockito

    CERN Document Server

    Kaczanowski, Tomek

    2013-01-01

    This book explains in detail how to implement unit tests using two very popular open source Java technologies: JUnit and Mockito. It presents a range of techniques necessary to write high quality unit tests - e.g. mocks, parametrized tests and matchers. It also discusses trade-offs related to the choices we have to make when dealing with some real-life code issues. The book stresses the importance of writing readable and maintainable unit tests, and puts a lot of stress on code quality. It shows how to achieve testable code and to eliminate common mistakes by following the Test Driven Development approach. Every topic discussed in the book is illustrated with code examples, and each chapter is accompanied by some exercises. By reading this book you will: Grasp the role and purpose of unit tests Write high-quality, readable and maintainable unit tests Learn how to use JUnit and Mockito (but also other useful tools) Avoid common pitfalls when writing unit tests Recognize bad unit tests, a...

  17. Unit area control in California forests

    Science.gov (United States)

    William E. Hallin

    1951-01-01

    There is a definite distinction between the basic concept of unit area control and the specific techniques or treatments used for specific units. Unit area control as a term was first used in connection with a cutting trial in the sugar pine-fir type; consequently, many foresters think the term refers merely to the technique used in sugar pine management, This is not...

  18. Safety Evaluation Report related to the operation of Comanche Peak Steam Electric Station, Unit 2 (Docket No. 50-446)

    International Nuclear Information System (INIS)

    1993-02-01

    Supplement 26 to the Safety Evaluation Report related to the operation of the Comanche Peak Steam Electric Station (CPSES), Unit 2, has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission (NRC). The facility is located in Somervell County, Texas, approximately 40 miles southwest of Fort Worth, Texas. This supplement reports the status of certain issues that had not been resolved when the Safety Evaluation Report and Supplements 1, 2, 3, 4, 6, 12, 21, 22, 23, 24, and 25 to that report were published. This supplement deals primarily with Unit 2 issues; however, it also references evaluations for several licensing issues that relate to Unit 1, which have been resolved since Supplement 25 was issued

  19. 78 FR 70274 - United States Travel and Tourism Advisory Board: Meeting of the United States Travel and Tourism...

    Science.gov (United States)

    2013-11-25

    ... DEPARTMENT OF COMMERCE International Trade Administration United States Travel and Tourism Advisory Board: Meeting of the United States Travel and Tourism Advisory Board AGENCY: International Trade... the schedule and agenda for an open meeting of the United States Travel and Tourism Advisory Board...

  20. 78 FR 3398 - United States Travel and Tourism Advisory Board: Meeting of the United States Travel and Tourism...

    Science.gov (United States)

    2013-01-16

    ... DEPARTMENT OF COMMERCE International Trade Administration United States Travel and Tourism Advisory Board: Meeting of the United States Travel and Tourism Advisory Board AGENCY: International Trade... the schedule and agenda for an open meeting of the United States Travel and Tourism Advisory Board...

  1. 28 CFR 541.47 - Admission to control unit.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Admission to control unit. 541.47 Section... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.47 Admission to control unit. Staff shall provide an inmate admitted to a control unit with: (a) Notice of the projected duration of...

  2. Management of planned unit outages

    International Nuclear Information System (INIS)

    Brune, W.

    1984-01-01

    Management of planned unit outages at the Bruno Leuschner Nuclear Power Plant is based on the experience gained with Soviet PWR units of the WWER type over a period of more than 50 reactor-years. For PWR units, planned outages concentrate almost exclusively on annual refuellings and major maintenance of the power plant facilities involved. Planning of such major maintenance work is based on a standardized basic network plan and a catalogue of standardized maintenance and inspection measures. From these, an overall maintenance schedule of the unit and partial process plans of the individual main components are derived (manually or by computer) and, in the temporal integration of major maintenance at every unit, fixed starting times and durations are determined. More than 75% of the maintenance work at the Bruno Leuschner Nuclear Power Plant is carried out by the plant's own maintenance personnel. Large-scale maintenance of every unit is controlled by a special project head. He is assisted by commissioners, each of whom is responsible for his own respective item. A daily control report is made. The organizational centre is a central office which works in shifts around the clock. All maintenance orders and reports of completion pass through this office; thus, the overall maintenance schedule can be corrected daily. To enforce the proposed operational strategy, suitable accompanying technical measures are required with respect to effective facility monitoring and technical diagnosis, purposeful improvement of particularly sensitive components and an increase in the effectiveness of maintenance work by special technologies and devices. (author)

  3. Are federal sustained yield units equitable? A case study of the Grays Harbor unit.

    Science.gov (United States)

    Con H Schallau; Wilbur R. Maki

    1986-01-01

    The Grays Harbor Federal Sustained Yield Unit (U.S. Department of Agriculture, Forest Service) was established in 1949 to enhance the economic stability of the forest products industry and dependent communities in Grays Harbor County, Washington. Provisions of the unit's charter require that all logs harvested from the Quinault Ranger District of the Olympic...

  4. A computer controlled tele-cobalt unit

    International Nuclear Information System (INIS)

    Brace, J.A.

    1982-01-01

    A computer controlled cobalt treatment unit was commissioned for treating patients in January 1980. Initially the controlling computer was a minicomputer, but now the control of the therapy unit is by a microcomputer. The treatment files, which specify the movement and configurations necessary to deliver the prescribed dose, are produced on the minicomputer and then transferred to the microcomputer using minitape cartridges. The actual treatment unit is based on a standard cobalt unit with a few additional features e.g. the drive motors can be controlled either by the computer or manually. Since the treatment unit is used for both manual and automatic treatments, the operational procedure under computer control is made to closely follow the manual procedure for a single field treatment. The necessary safety features which protect against human, hardware and software errors as well as the advantages and disadvantages of computer controlled radiotherapy are discussed

  5. Cultural traits as units of analysis.

    Science.gov (United States)

    O'Brien, Michael J; Lyman, R Lee; Mesoudi, Alex; VanPool, Todd L

    2010-12-12

    Cultural traits have long been used in anthropology as units of transmission that ostensibly reflect behavioural characteristics of the individuals or groups exhibiting the traits. After they are transmitted, cultural traits serve as units of replication in that they can be modified as part of an individual's cultural repertoire through processes such as recombination, loss or partial alteration within an individual's mind. Cultural traits are analogous to genes in that organisms replicate them, but they are also replicators in their own right. No one has ever seen a unit of transmission, either behavioural or genetic, although we can observe the effects of transmission. Fortunately, such units are manifest in artefacts, features and other components of the archaeological record, and they serve as proxies for studying the transmission (and modification) of cultural traits, provided there is analytical clarity over how to define and measure the units that underlie this inheritance process.

  6. United Nations and Multilateralism: Appraising USA's Unilateralism ...

    African Journals Online (AJOL)

    DrNneka

    global peace and security, as well as the survival of the United Nations. This is because ... Key Words: United Nations, multilateralism, United States, unilateralism, national interest, UN Charter ..... Lebanon, Iraq, Turkey, Egypt, Jordan, etc.

  7. Bruce Unit 2 lay-up engineering assessment

    International Nuclear Information System (INIS)

    Iley, D.

    1995-01-01

    The overall lay-up program initiated as a result of the strategic decision to shut down Bruce A unit 2 is briefly described as an introduction to the engineering assessment of the unit 2 systems. The assessment has identified the need to prepare 67 system and 9 equipment lay-up specifications. A summary of the selected system specifications is described. A complete summary and the specifications and the status of unit 2 systems and equipment required to support lay-up and/or the other three operating units is available on request due to the volume of the information. Some logistical details of the lay-up implementation plans, results, and problems to date demonstrate the complexity of the lay-up requirements for a nuclear unit in a multi-unit CANDU station. (author)

  8. Stabilization of gas turbine unit power

    Science.gov (United States)

    Dolotovskii, I.; Larin, E.

    2017-11-01

    We propose a new cycle air preparation unit which helps increasing energy power of gas turbine units (GTU) operating as a part of combined cycle gas turbine (CCGT) units of thermal power stations and energy and water supply systems of industrial enterprises as well as reducing power loss of gas turbine engines of process blowers resulting from variable ambient air temperatures. Installation of GTU power stabilizer at CCGT unit with electric and thermal power of 192 and 163 MW, respectively, has resulted in reduction of produced electrical energy production costs by 2.4% and thermal energy production costs by 1.6% while capital expenditures after installation of this equipment increased insignificantly.

  9. Legal and Regulatory Barriers to Reverse Innovation.

    Science.gov (United States)

    Rowthorn, Virginia; Plum, Alexander J; Zervos, John

    Reverse innovation, or the importation of new, affordable, and efficacious models to high-income countries from the developing world, has emerged as a way to improve the health care system in the United States. Reverse innovation has been identified as a key emerging trend in global health systems in part because low-resourced settings are particularly good laboratories for low-cost/high-impact innovations that are developed out of necessity. A difficult question receiving scant attention is that of legal and regulatory barriers. The objective of this paper is to understand and elucidate the legal barriers faced by innovators bringing health interventions to the United States. Semistructured qualitative interviews were conducted with 9 key informants who have directly participated in the introduction of global health care approaches to the United States health system. A purposive sampling scheme was employed to identify participants. Phone interviews were conducted over one week in July 2016 with each participant and lasted an average of 35 minutes each. Purely legal barriers included questions surrounding tort liability, standard of care, and concerns around patient-administered self-care. Regulatory burdens included issues of international medical licensure, reimbursement, and task shifting and scope of work challenges among nonprofessionals (e.g. community health workers). Finally, perceived (i.e. not realized or experienced) legal and regulatory barriers to innovative modalities served as disincentives to bringing products or services developed outside of the United States to the United States market. Conflicting interests within the health care system, safety concerns, and little value placed on low-cost interventions inhibit innovation. Legal and regulatory barriers rank among, and contribute to, an anti-innovation atmosphere in healthcare for domestic and reverse innovators alike. Reverse innovation should be fostered through the thoughtful development of

  10. The Unitality of Quantum B-algebras

    Science.gov (United States)

    Han, Shengwei; Xu, Xiaoting; Qin, Feng

    2018-02-01

    Quantum B-algebras as a generalization of quantales were introduced by Rump and Yang, which cover the majority of implicational algebras and provide a unified semantic for a wide class of substructural logics. Unital quantum B-algebras play an important role in the classification of implicational algebras. The main purpose of this paper is to construct unital quantum B-algebras from non-unital quantum B-algebras.

  11. Science Unit Plans. PACE '94.

    Science.gov (United States)

    Schoon, Kenneth J., Ed.; Wiles, Clyde A., Ed.

    This booklet contains mathematics unit plans for Biology, Chemistry, and Physical Science developed by PACE (Promoting Academic Excellence In Mathematics, Science & Technology for Workers of the 21st Century). Each unit plan contains suggested timing, objectives, skills to be acquired, workplace relationships, learning activities with suggested…

  12. 78 FR 40200 - Duke Energy Carolinas, LLC, Oconee Nuclear Station Units 1, 2, and 3; Independent Spent Fuel...

    Science.gov (United States)

    2013-07-03

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 72-1004, 72-40, 50-269, 50-270, and 50-287; NRC-2013-0135] Duke Energy Carolinas, LLC, Oconee Nuclear Station Units 1, 2, and 3; Independent Spent Fuel Storage Installation; Environmental Assessment and Finding of No Significant Impact AGENCY: Nuclear...

  13. [Work setting, satisfaction and burnout of the nurses in critical care units and hospitalization units. RN4CAST-Spain project].

    Science.gov (United States)

    Fuentelsaz-Gallego, C; Moreno-Casbas, T; Gómez-García, T; González-María, E

    2013-01-01

    To know if there are differences between the critical care units and the medical-surgical care units regarding the perception of the nurses working in National Health System hospitals about their work environment, burnout level and job satisfaction. A cross-sectional study was conducted with 6,417 nurses from the medical-surgical care units and with 1,122 nurses from critical care units of 59 Spanish hospitals with more than 150 beds. Socio-demographic, job satisfaction, perception of work environment (Practice Environment Scale of the Nursing Work Index [PES-NWI questionnaire]) and burnout measured with the Maslach Burnout Inventory (MBI) data were collected. The PES-NWI showed differences in 4 out of its 5 factors. It showed better values in medical-surgical units in all the factors, except for Staffing and resource adequacy (P<.001), where critical care units showed a mean level of agreement of 2.41 versus 2.19 for the medical-surgical units. Regarding burnout, this was higher in the medical-surgical care units (P=.039) where 23% (952) of the nurses had high levels. Job satisfaction was lower in the critical care units (P=.044) with 70% (578) of nurses being very or strongly satisfied. The opinion of the nurses, working in critical care units about their hospital is unfavorable. They showed lower levels of burnout than those working in medical-surgical units. Copyright © 2013 Elsevier España, S.L. y SEEIUC. All rights reserved.

  14. [Factors affecting the recovery in the intensive care unit].

    Science.gov (United States)

    Turkov, P N; Nikitin, V V; Antsupova, M A; Podkopaev, V N; Panfilova, R P; Ivanova, I N; Nesterova, L I

    2013-01-01

    Urgency of the problem is defined by economical, regulatory and legislative acts, regional social and moral factors. There is critical situation in Russian Pediatric Healthcare system. This situation is due to inadequate funding, high medical technologies inaccessibility for some Russian children, their adverse health state. The article presents a retrospective analysis of intensive therapy and resuscitation outcomes with technical equipment and work environment assessment in the intensive care unit of Tushinskaya city pediatric clinic for the period from 2007 to 2011. Anaesthetic and emergency care quality and safety depend on several factors: permanent equipment improvement, comprehensive analysis of every fatal case and full implementation of "Anti-epidemic (prophylactic) actions plan" and "Program of monitoring compliance with the sanitary norms".

  15. The Regulatory Independence of FANR

    International Nuclear Information System (INIS)

    ALNuaimi, Fatema; Choi, Kwang Shik

    2012-01-01

    Regulatory independence is meant to provide a conservative system of policy making in order to comply with the problems that are forecasted upon the basis of assumptions. The Federal Authorization of Nuclear Regulation (FANR) is a regulatory commission that was formed to be regulatory body that governs the generation of nuclear power in United Arab Emirates. It was established under the UAE nuclear law (9/2009) as an independent regulatory body that was tasked with the regulation of all nuclear activities in the United Arab Emirates. As an independent body, FANR was tasked with ensuring that the regulation of the nuclear sector is done in effective and transparent manner to ensure its accountability to the people. Being independent, the regulatory body develops national nuclear regulations based on laid down safety standards by the International Atomic Energy Agency, ensuring that they are based on scientific and proven technologies The role of FANR is to ensure that the all corporations that undertake nuclear activities follow the laid down procedures and objectives and ensure safety measures are taken keenly to ensure the safety of the workers and the general public while at the same time ensuring the environment is free from nuclear radiations

  16. The Regulatory Independence of FANR

    Energy Technology Data Exchange (ETDEWEB)

    ALNuaimi, Fatema; Choi, Kwang Shik [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2012-05-15

    Regulatory independence is meant to provide a conservative system of policy making in order to comply with the problems that are forecasted upon the basis of assumptions. The Federal Authorization of Nuclear Regulation (FANR) is a regulatory commission that was formed to be regulatory body that governs the generation of nuclear power in United Arab Emirates. It was established under the UAE nuclear law (9/2009) as an independent regulatory body that was tasked with the regulation of all nuclear activities in the United Arab Emirates. As an independent body, FANR was tasked with ensuring that the regulation of the nuclear sector is done in effective and transparent manner to ensure its accountability to the people. Being independent, the regulatory body develops national nuclear regulations based on laid down safety standards by the International Atomic Energy Agency, ensuring that they are based on scientific and proven technologies The role of FANR is to ensure that the all corporations that undertake nuclear activities follow the laid down procedures and objectives and ensure safety measures are taken keenly to ensure the safety of the workers and the general public while at the same time ensuring the environment is free from nuclear radiations

  17. Nuclear Regulatory Commission Issuances, September 1981

    International Nuclear Information System (INIS)

    1981-01-01

    Contents include: Issuances of the Nuclear Regulatory Commission--Commonwealth Edison Company (Dresden Nuclear Power Station, Unit 1), Consolidated Edison Company of New York (Indian Point, Unit 2), Metropolitan Edison Company, et al. (Three Mile Island Nuclear Station, Unit 1), Pacific Gas and Electric Company (Diablo Canyon Nuclear Power Plant, Units 1 and 2), Pacific Gas and Electric Company (Diablo Canyon Nuclear Power Plant, Units 1 and 2), Power Authority of the State of New York (Indian Point, Unit 3), Texas Utilities Generating Company, et al. (Comanche Peak Steam Electric Station, Units 1 and 2); Issuances of Atomic Safety and Licensing Appeal Boards--Pacific Gas and Electric Company (Diablo Canyon Nuclear Power Plant, Units 1 and 2), Philadelphia Electric Company, et al. (Peach Bottom Atomic Power Statin, Units 2 and 3), Metropolitan Edison Company, et al. (Three Mile Island Nuclear Statin, Unit No. 2), Public Service Electric and Gas Company (Hope Creek Generating Station, Units 1 and 2), The Toledo Edison Company, et al. (Davis-Besse Nuclear Power Station, Units 2 and 3); Issuances of the Atomic Safety Licensing Boards--Cleveland Electric Illuminating Company, et al. (Perry Nuclear Power Plant, Units 1 and 2), Commonwealth Edison Company (Dresden Station, Units 2 and 3), Houston Lighting and Power Company (Allens Creek Nuclear Generating Station, Unit 1), Southern California Edison Company, et al. (San Onofre Nuclear Generating Station, Units 2 and 3), Texas Utilities Generating Company, et al. (Comanche Peak Steam Electric Station, Units 1 and 2), Texas Utilities Generating Company, et al

  18. Labeling of genetically modified food: closer to reality in the United States?

    Science.gov (United States)

    Wohlers, Anton E

    2013-01-01

    Within the broader context of several related biotech developments, including the proliferation of GM food in American grocery stories, the recent decision by Whole Foods Market, Inc. to require the labeling of all genetically modified (GM) organism products sold in its stores by 2018, and the development of GM animals for consumption, this essay asks whether the United States is inching towards a policy of mandatory GM food labeling. The analysis highlights aspects of the biotechnology policy debate in the United States and European Union, and traces public opinion as well as grassroots and legislative efforts aimed at GM food labeling. Findings show that activities at the federal level do not suggest any major regulatory changes regarding labeling in the near future; however, a growing number of individual states are considering GM food labeling legislation and political momentum in favor of labeling has picked up in recent years. Voluntary labeling by food companies may also become increasingly common.

  19. Regulatory acceptance of the proposed well abandonment program for the present landfill, Operable Unit 7, Rocky Flats Environmental Technology Site, Golden, Colorado

    International Nuclear Information System (INIS)

    Wood, M.R.

    1995-01-01

    The regulatory agencies approved a well abandonment program for the Present Landfill, Operable Unit (OU) 7 at the Rocky Flats Environmental Technology Site, only three months after preparation. The proposed well abandonment program consists of abandoning 26 of the 54 existing monitoring wells in OU 7 that are currently sampled quarterly as Resource Conservation and Recovery Act (RCRA) compliance wells or sitewide groundwater protection wells. Well abandonment was proposed on the basis that the purpose of each well has been fulfilled, the wells fall under the footprint of the landfill cap, the presence of the wells would compromise the integrity of the cap because holes would have to be cut in the synthetic liner, and unequal compaction of the fill material around the wells would potentially cause differential settlement of the cap. The proposal provided the technical justification to abandon the wells in place. The timely approval of the proposal by the regulatory agencies will allow the abandonment of the wells during fiscal year 1995 under the sitewide Well Abandonment and Replacement Program (WARP). Cost savings resulting from a decrease in the number of wells to be sampled under the groundwater monitoring program are estimated at $416,000 per year. This paper presents a summary of the well abandonment program, discusses the timely approvals required for implementation, and present the potential cost savings that can be achieved through implementation of the program

  20. The Regulatory Framework for Privacy and Security

    Science.gov (United States)

    Hiller, Janine S.

    The internet enables the easy collection of massive amounts of personally identifiable information. Unregulated data collection causes distrust and conflicts with widely accepted principles of privacy. The regulatory framework in the United States for ensuring privacy and security in the online environment consists of federal, state, and self-regulatory elements. New laws have been passed to address technological and internet practices that conflict with privacy protecting policies. The United States and the European Union approaches to privacy differ significantly, and the global internet environment will likely cause regulators to face the challenge of balancing privacy interests with data collection for many years to come.

  1. Rise and fall of nuclear power in the United States and the limits of regulation

    International Nuclear Information System (INIS)

    Del Sesto, S.L.

    1982-01-01

    This paper documents the rapid growth of nuclear power in the United States and its subsequent decline in the late 1970s. It demonstrates that the increase in numbers of new orders for nuclear plants created pressures for additional licensing complexity to insure safety and provide public intervenors with opportunities to participate in the regulatory process. The resulting protraction of the licensing process combined with increasing political opposition to nuclear power caused construction delays and bureaucratic bottlenecks at a time when soaring interest rates and double-digit inflation have pushed the cost of building new facilities out of the reach of the financially battered utility industry. Together with a downturn in demand for electricity and increasing uncertainty over nuclear power, no reactor orders have been placed since late 1978. It is argued that renewed growth of nuclear power in the United States is unlikely, especially in a regulatory environment which fosters increased costs of electricity to consumers and a simultaneous abrogation of the economies of scale. The consequences of the impending atrophication of the nuclear industry in America and its effects on future energy mixes and long-term national interests must be considered in future nuclear policies and reforms

  2. Proposed plan for interim remedial measures at the 100-KR-1 Operable Unit. Revision 1

    International Nuclear Information System (INIS)

    1995-09-01

    This proposed plan identifies the preferred alternative for interim remedial measures for remedial action of radioactive liquid waste disposal sites that include contaminated soils and structures at the 100-KR-1 Operable Unit, located at the Hanford Site. It also summarizes other remedial alternatives evaluated for interim remedial measures in this Operable Unit. The intent of interim remedial measures is to speed up actions to address contaminated areas that pose potential threats to human health and the environment. This proposed plan is being issued by the US Environmental Protection Agency (EPA), the lead regulatory agency; the Washington State Department of Ecology (Ecology), the support regulatory agency; and the US Department of Energy (DOE), the responsible agency. The EPA, Ecology, and the DOE are issuing this proposed plan as part of their public participation responsibilities under Section 117(a) of the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA), commonly known as the ''Superfund Law.'' This proposed plan is intended to be a fact sheet for public review which briefly describes the remedial alternatives analyzed, identifies a preferred alternative, and summarizes the information relied upon to recommend the preferred alternative

  3. Definitions of Quantities and Units.

    Science.gov (United States)

    Spurgin, C. B.

    1983-01-01

    Compares various methods of defining derived quantities, arguing for a definitional formula using base or fundamental units in a word equation, or symbol-equations with the symbols explained. Suggests that fundamental units be defined operationally or left regarded as intuitive as in the case of length and time. (JM)

  4. Regulatory frameworks for hydropower in Europe. Comparing the examples of Germany, France and the United Kingdom; Regulatorische Rahmenbedingungen fuer die Wasserkraftnutzung in Europa am Beispiel der Laender Deutschland, Frankreich und Grossbritannien

    Energy Technology Data Exchange (ETDEWEB)

    Krull, Devid; Schneider, Claus Till; Detering, Michael [innogy SE, Essen (Germany). Sparte Erneuerbare Energien; Logie, Andrew [innogy SE, Perth (United Kingdom). Hydro Development; Seyler, Juergen [Energies France S.A.S., Paris (France)

    2016-11-01

    The regulatory framework for hydro power in the European countries Germany, United Kingdom and France is compared. All have as a common target on the one hand an increase of the share of renewable energy production and to this means a support regime for hydro power among other renewable technologies. The respective support mechanisms in the three countries are summarised. As part of the implementation of the European Water Framework Directive the countries formulate stricter environmental requirements for water bodies leading to reduced electricity generation and necessary investments in technical adaptations.

  5. GENDER ISSUES: Perceptions of Readiness in Selected Units

    National Research Council Canada - National Science Library

    1999-01-01

    .... More than 13,000 women have joined these units.3 Among the units that have opened to women are Army smoke and chemical companies, forward support battalions, air defense artillery headquarters' units, military police units, and engineer companies...

  6. Safety evaluation report related to the operation of LaSalle County Station, Units 1 and 2, (Docket Nos. 50-373 and 50-374). Supplement No. 7

    International Nuclear Information System (INIS)

    1983-12-01

    Supplement No. 7 to the Safety Evaluation Report of Commonwealth Edison Company's application for a license to operate its La Salle County Station, Unit 2, located on Brookfield Township, La Salle County, Illinois, has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. This supplement is to update our evaluations on Unit 2 issues identified in the previous Safety Evaluation Report and Supplements that need resolution prior to issuance of the operating license for Unit 2

  7. Safety Evaluation Report related to the operation of Nine Mile Point Nuclear Station, Unit No. 2 (Docket No. 50-410)

    International Nuclear Information System (INIS)

    1987-07-01

    This report supplements the Safety Evaluation Report (NUREG-1047, February 1985) for the application filed by Niagara Mohawk Power Corporation, as applicant and co-owner, for the license to operate Nine Mile Point Nuclear Station, Unit 2 (Docket No. 50-410). It has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. The facility is located near Oswego, New York. This report supports the issuance of the full-power license for Nine Mile Point Nuclear Station, Unit No. 2

  8. 76 FR 19148 - PSEG Nuclear, LLC, Hope Creek Generating Station and Salem Nuclear Generating Station, Units 1...

    Science.gov (United States)

    2011-04-06

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-272, 50-311, 50-354; NRC-2009-0390 and NRC-2009-0391] PSEG Nuclear, LLC, Hope Creek Generating Station and Salem Nuclear Generating Station, Units 1 and 2..., DPR-70, and DPR-75 for an additional 20 years of operation for the Hope Creek Generating Station (HCGS...

  9. 75 FR 16201 - FPL Energy Point Beach, LLC; Point Beach Nuclear Plant, Units 1 and 2; Exemption

    Science.gov (United States)

    2010-03-31

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-266 and 50-301; NRC-2010-0123] FPL Energy Point Beach, LLC; Point Beach Nuclear Plant, Units 1 and 2; Exemption 1.0 Background FPL Energy Point Beach.... Borchardt (NRC) to M. S. Fertel (Nuclear Energy Institute) dated June 4, 2009. The licensee's request for an...

  10. Emergency operating instruction improvements at San Onofre Nuclear Generating Station Units 2 and 3

    International Nuclear Information System (INIS)

    Trillo, M.W.; Smith, B.H.

    1989-01-01

    In late 1987, San Onofre nuclear generating station (SONGS) began an extensive upgrade of the units 2 and 3 emergency operating instructions (EOIs). The original intent of this program was to incorporate revised generic guidance and to correct problems that were identified by operators. While this program was in progress, the US Nuclear Regulatory Commission (NRC) conducted a series of audits of emergency operating procedure (EOP) development and maintenance programs as 16 commercial nuclear facilities in the United States. These audits included four stations with Combustion Engineering-designed nuclear steam supply systems. (One of these audits included a review of preupgrade SONGS units 2 and 3 EOIs.) Significant industrywide comments resulted from these audits. The NRC has stated its intent to continue the review and audit of EOIs and the associated maintenance programs at all US commercial nuclear facilities. The units 2 and 3 EOI upgrade program developed procedural improvements and procedural program maintenance improvements that address many of the existing audit comments that have been received by the industry. Other resulting improvements may be useful in minimizing NRC comments in future such audits. Specific improvements are discussed. The upgrade program resulted in benefits that were not originally anticipated. The results of this program can be of significant use by other utilities in addressing the industrywide concerns that have been raised in recent NRC audits of EOP development and maintenance programs

  11. Prospects of Nuclear Energy in the United States in the 21st Century

    International Nuclear Information System (INIS)

    Newman, R. E.

    1988-01-01

    The Nuclear Industry is now over 40 years old and a proven, mature product has been developed. That proven mature product has evolve into a small set of standardized designs - designs based on evolution of the best and safest features, not revolutionary changes. Just as the product design must be standardized, the regulatory process must also be standardized. With a predictable regulatory environment and rate structure the economic advantages of Nuclear Power will be self-evident. The Nuclear Industry in the United States has had a history of cycles as the economy and need for power has changed. The need for electricity to support growth is a given. With a strong focus on the standardization of the process and the product, a competent engineering approach to safety, and improved economies, the 21st century will see nuclear power assume its appropriate role as a key source in the energy mix in the United States. Presenting a discussion dealing with the future is always a risky thing. One man's prognosis is another mans wild guess. Today, I would like to talk briefly on my views of the future, and especially my views on the Prospects for Nuclear Energy in the U. S. in that future. Though it is clear that nuclear energy will play a key role in fulfilling the energy needs of the world, the future of nuclear energy in the United States is not as clear. A discussion of the future of the U. S. Nuclear Industry is especially appropriate here today because I am firmly confident that the Republic of Korea will play a major role in that future. The world energy situation and the role of nuclear power has undergone a number of upsets in the last decade. Often we tend to dwell on the gloom of the past and overlook the strengths that the Nuclear Industry has developed. Presently over 437 gigawatts of electricity in the world is planned to be produced by 564 nuclear units. There are over 32 countries with commercial nuclear programs. One of the brightest of these being here in

  12. 76 FR 13209 - United States and State of Texas v. United Regional Health Care System; Proposed Final Judgment...

    Science.gov (United States)

    2011-03-10

    ... of Texas v. United Regional Health Care System, Civil Action No. 7:11-cv- 00030-O. On February 25..., ambulatory surgery center or radiology center in [a] 15 mile radius of United Regional Health Care System... 95% of billed charges for all inpatient and outpatient services at United Regional Health Care System...

  13. Public and nonprofit funding for research on mental disorders in France, the United Kingdom, and the United States.

    Science.gov (United States)

    Chevreul, Karine; McDaid, David; Farmer, Carrie M; Prigent, Amélie; Park, A-La; Leboyer, Marion; Kupfer, David J; Durand-Zaleski, Isabelle

    2012-07-01

    To document the investments made in research on mental disorders by both government and nonprofit nongovernmental organizations in France, the United Kingdom, and the United States. An exhaustive survey was conducted of primary sources of public and nonprofit organization funding for mental health research for the year 2007 in France and the United Kingdom and for fiscal year 2007-2008 in the United States, augmented with an examination of relevant Web sites and publications. In France, all universities and research institutions were identified using the Public Finance Act. In the United Kingdom, we scrutinized Web sites and hand searched annual reports and grant lists for the public sector and nonprofit charitable medical research awarding bodies. In the United States, we included the following sources: the National Institutes of Health, other administrative entities within the Department of Health and Human Services (eg, Centers for Disease Control and Prevention), the Department of Education, the Department of Veterans Affairs, the Department of Defense, and the National Science Foundation and, for nonprofit funding, The Foundation Center. We included research on all mental disorders and substance-related disorders using the same keywords. We excluded research on mental retardation and dementia and on the promotion of mental well-being. We used the same algorithm in each country to obtain data for only mental health funding in situations in which funding had a broader scope. France spent $27.6 million (2%) of its health research budget on mental disorders, the United Kingdom spent $172.6 million (7%), and the United States spent $5.2 billion (16%). Nongovernmental funding ranged from 1% of total funding for mental health research in France and the United States to 14% in the United Kingdom. Funding for research on mental disorders accounts for low proportions of research budgets compared with funding levels for research on other major health problems, whereas

  14. Reactivation of nuclear power plant construction projects. Plant status, policy issues and regulatory options

    International Nuclear Information System (INIS)

    Spangler, M.B.

    1986-07-01

    Prior to the TMI-2 accident on March 28, 1979, four nuclear power plant units that had previously been issued a construction permit were cancelled, principally because of reduced projections of regional power demand. Since that time, an additional 31 units with CPs have been cancelled and eight units deferred. On December 23, 1985 one of the deferred units (Limerick-2) was reactivated and construction resumed. The primary objective of this policy study is to identify the principal issues requiring office-level consideration in the event of reactivation of the construction of one or more of the nuclear power plants falling into two categories: (1) LWR units issued a construction permit whose construction has been cancelled, and (2) LWR units whose construction has been deferred. The study scope is limited to identifying regulatory issues or questions deserving analysis rather than providing, at this time, answers or recommended actions. Five tasks are addressed: a tabulation and discussion of the status of all cancelled and deferred LWR units; and identification of potential safety and environmental issues; an identification of regulatory or policy issues and needed information to determine the desirability of revising certain rules and policies; and identification of regulatory options and decision criteria; and an identification of decision considerations in determining staff requirements and organizational coordination of LWR reactivation policy and implementation efforts. 41 refs

  15. Assessment of hydrologic impact of extending exploratory shafts into the Calico Hills nonwelded tuff unit at Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Nichols, W.E.; Freshley, M.D.; Rockhold, M.L.

    1991-03-01

    The US Department of Energy (DOE) is performing analyses to address an objection by the US Nuclear Regulatory Commission to plans in the Consultation Draft of the Site Characterization Plan for direct excavation of the Calico Hills nonwelded (CHn) unit within the repository exploration block at Yucca Mountain, Nevada. The excavation was planned as part of site characterization activities for the potential high-level nuclear waste repository at Yucca Mountain. This characterization activities for the potential high-level nuclear waste repository at Yucca Mountain. This characterization activity has been deferred, pending the results of a risk/benefit analysis of alternative methods for obtaining needed characterization data from CHn unit. The benefits from characterizing the CHn unit are generally related to obtaining information leading to improved confidence in predictions of site performance. The risks are generally associated with potential adverse impacts to site performance that result from excavation or other intrusion into the CHn unit. The purpose of the risk/benefit analysis is to produce a recommendation to the Director, Regulatory and Site Evaluation Division. DOE/Yucca Mountain Site Characterization Project Office for a strategy for characterizing the CHn unit. The recommendation will describe characterization activities that are expected to provide the needed information while limiting adverse impacts to site performance to the extent practical. The risk/benefit analysis was supported with scoping calculations to provide a quantitative evaluation of the impacts associated with different strategies. The working group responsible for the risk/benefit analysis requested that these scoping calculations to be supported with more detailed performance assessments for evaluating impacts of different characterization activities. This report summarizes the results of these performance assessment analyses. 9 refs., 30 figs., 1 tab

  16. Fatigue in Breakwater Concrete Armour Units

    OpenAIRE

    Burcharth, Hans F.

    1984-01-01

    The reliability of rubble mound breakwaters depends on the hydraulic stability and the mechanical strength of the armour units. The paper deals with the important aspect of fatigue related to the strength of concrete armour units. Results showing significant fatigue from impact tests with Dolosse made of unreinforced and steel fibre reinforced flyash concrete are presented. Moreover universal graphs for fatigue in armour units made of conventional unreinforced concrete exposed to impact load ...

  17. The Linkage Between Work Unit Performance Perceptions of U.S. Federal Employees and Their Job Satisfaction: An Expectancy Theory

    Directory of Open Access Journals (Sweden)

    Soyoung PARK

    2018-02-01

    Full Text Available Public organizations are interested in how to improve their performance. Performance in a work unit can also influence employee job satisfaction due to positive expectations based on higher performance. Thus, our study attempts to investigate if organizational performance has an impact on employee motivation under the premise that employees who perform better in a work unit expect greater professional recognition and rewards. By using data from the 2013 Federal Employee Viewpoint Survey (FEVS, we find that employees who perceive higher levels of performance in a work unit have a higher level of job satisfaction. This paper further shows that performance perception based on rewards is also positively related to job satisfaction.However, underrepresented groups (female and non-white, older employees and mid-level (work experience from 6 to 14 years employees are less satisfied with higher work unit performance. Finally, employees in the distributive agency category are more satisfied with work unit performance while those in the regulatory agency category are less satisfied with work unit performance. In conclusion, organizations should recognize particular characteristics of employees to develop the policies related to performance management, and effectively utilize these policies in order to attract and retain proficient workers.

  18. Comparative study of radiation dose between digital panoramic X-ray unit and general panoramic X-ray unit

    International Nuclear Information System (INIS)

    Li Qingshan; Duan Tao; Wang Xiaoyun; Zhao Li; Dong Jian; Wei Lei

    2010-01-01

    Objective: To compare the actual dose of patients who receive the same medical practice by either digital panoramic X-ray unit and general panoramic X-ray unit and give evidence for better selection of oral X-ray examination method. Methods: Round sheet lithium fluoride (LiF) thermoluminescent dosimeters (TLD) were used. The experiment was divided into natural background contrast group, general panoramic X-ray children group, general panoramic X-ray adults group, digital panoramic X-ray children group and digital panoramic X-ray adults group. The dosimeter of natural background radiation was placed at the office of the doctor, the dosimeters of general panoramic X-ray children group and general panoramic X-ray adults group were irradiated by different conditions according to the clinical application of panoramic X-ray to children and adults, the dosimeters of digital panoramic X-ray children group and digital panoramic X-ray adults group were irradiated by different conditions according to the clinical application of digital panoramic X-ray to children and adults. The thermoluminescent dosimeter was used to count and calculate the exposure doses in various groups. Results: The dose of children exposed in general panoramic X-ray unit was 1.28 times of that in digital panoramic X-ray unit, there was significant difference (t=6.904, P<0.01). The dose of adults exposed in general panoramic X-ray unit was 1.55 times of that in the digital panoramic X-ray unit, there also was significant difference (t=-11.514. P< 0.01). Conclusion: The digital panoramic X-ray unit can reduce the dose of patients, so the digital panoramic X-ray unit should be used as far as possible. (authors)

  19. Key considerations for the success of Medical Education Research and Innovation units in Canada: unit director perceptions.

    Science.gov (United States)

    Varpio, Lara; Bidlake, Erin; Humphrey-Murto, Sue; Sutherland, Stephanie; Hamstra, Stanley J

    2014-08-01

    Growth in the field of medical education is evidenced by the proliferation of units dedicated to advancing Medical Education Research and Innovation (MERI). While a review of the literature discovered narrative accounts of MERI unit development, we found no systematic examinations of the dimensions of and structures that facilitate the success of these units. We conducted qualitative interviews with the directors of 12 MERI units across Canada. Data were analyzed using qualitative description (Sandelowski in Res Nurs Health 23:334-340, 2000). Final analysis drew on Bourdieu's (Outline of a theory of practice. Cambridge University Press, Cambridge, 1977; Media, culture and society: a critical reader. Sage, London, 1986; Language and symbolic power. Harvard University Press, Cambridge, 1991) concepts of field, habitus, and capital, and more recent research investigating the field of MERI (Albert in Acad Med 79:948-954, 2004; Albert et al. in Adv Health Sci Educ 12:103-115, 2007). When asked about the metrics by which they define their success, directors cited: teaching, faculty mentoring, building collaborations, delivering conference presentations, winning grant funding, and disseminating publications. Analyzed using Bourdieu's concepts, these metrics are discussed as forms of capital that have been legitimized in the MERI field. All directors, with the exception of one, described success as being comprised of elements (capital) at both ends of the service-research spectrum (i.e., Albert's PP-PU structure). Our analysis highlights the forms of habitus (i.e., behaviors, attitudes, demeanors) directors use to negotiate, strategize and position the unit within their local context. These findings may assist institutions in developing a new-or reorganizing an existing-MERI unit. We posit that a better understanding of these complex social structures can help units become savvy participants in the MERI field. With such insight, units can improve their academic output and

  20. 28 CFR 541.49 - Review of control unit placement.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Review of control unit placement. 541.49... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.49 Review of control unit placement. (a) Unit staff shall evaluate informally and daily an inmate's adjustment within the control unit...

  1. Conceptual Model of Quantities, Units, Dimensions, and Values

    Science.gov (United States)

    Rouquette, Nicolas F.; DeKoenig, Hans-Peter; Burkhart, Roger; Espinoza, Huascar

    2011-01-01

    JPL collaborated with experts from industry and other organizations to develop a conceptual model of quantities, units, dimensions, and values based on the current work of the ISO 80000 committee revising the International System of Units & Quantities based on the International Vocabulary of Metrology (VIM). By providing support for ISO 80000 in SysML via the International Vocabulary of Metrology (VIM), this conceptual model provides, for the first time, a standard-based approach for addressing issues of unit coherence and dimensional analysis into the practice of systems engineering with SysML-based tools. This conceptual model provides support for two kinds of analyses specified in the International Vocabulary of Metrology (VIM): coherence of units as well as of systems of units, and dimension analysis of systems of quantities. To provide a solid and stable foundation, the model for defining quantities, units, dimensions, and values in SysML is explicitly based on the concepts defined in VIM. At the same time, the model library is designed in such a way that extensions to the ISQ (International System of Quantities) and SI Units (Systeme International d Unites) can be represented, as well as any alternative systems of quantities and units. The model library can be used to support SysML user models in various ways. A simple approach is to define and document libraries of reusable systems of units and quantities for reuse across multiple projects, and to link units and quantity kinds from these libraries to Unit and QuantityKind stereotypes defined in SysML user models.

  2. [Conservation Units.

    Science.gov (United States)

    Texas Education Agency, Austin.

    Each of the six instructional units deals with one aspect of conservation: forests, water, rangeland, minerals (petroleum), and soil. The area of the elementary school curriculum with which each correlates is indicated. Lists of general and specific objectives are followed by suggested teaching procedures, including ideas for introducing the…

  3. Mobile vapor recovery and vapor scavenging unit

    International Nuclear Information System (INIS)

    Stokes, C.A.; Steppe, D.E.

    1991-01-01

    This patent describes a mobile anti- pollution apparatus, for the recovery of hydrocarbon emissions. It comprises a mobile platform upon which is mounted a vapor recovery unit for recovering vapors including light hydrocarbons, the vapor recovery unit having an inlet and an outlet end, the inlet end adapted for coupling to an external source of hydrocarbon vapor emissions to recover a portion of the vapors including light hydrocarbons emitted therefrom, and the outlet end adapted for connection to a means for conveying unrecovered vapors to a vapor scavenging unit, the vapor scavenging unit comprising an internal combustion engine adapted for utilizing light hydrocarbon in the unrecovered vapors exiting from the vapor recovery unit as supplemental fuel

  4. Multi-Unit Considerations for Human Reliability Analysis

    Energy Technology Data Exchange (ETDEWEB)

    St. Germain, S.; Boring, R.; Banaseanu, G.; Akl, Y.; Chatri, H.

    2017-03-01

    This paper uses the insights from the Standardized Plant Analysis Risk-Human Reliability Analysis (SPAR-H) methodology to help identify human actions currently modeled in the single unit PSA that may need to be modified to account for additional challenges imposed by a multi-unit accident as well as identify possible new human actions that might be modeled to more accurately characterize multi-unit risk. In identifying these potential human action impacts, the use of the SPAR-H strategy to include both errors in diagnosis and errors in action is considered as well as identifying characteristics of a multi-unit accident scenario that may impact the selection of the performance shaping factors (PSFs) used in SPAR-H. The lessons learned from the Fukushima Daiichi reactor accident will be addressed to further help identify areas where improved modeling may be required. While these multi-unit impacts may require modifications to a Level 1 PSA model, it is expected to have much more importance for Level 2 modeling. There is little currently written specifically about multi-unit HRA issues. A review of related published research will be presented. While this paper cannot answer all issues related to multi-unit HRA, it will hopefully serve as a starting point to generate discussion and spark additional ideas towards the proper treatment of HRA in a multi-unit PSA.

  5. Nuclear Regulatory Commission Issuances, August 1981

    International Nuclear Information System (INIS)

    1981-01-01

    Contents include: Issuances of the Nuclear Regulatory Commission--Metropolitan Edison Company (Three Mile Island Nuclear Station, Unit No. 1), Metropolitan Edison Company, et al. (Three Mile Island Nuclear Station, Unit 1), Westinghouse Electric Corp. (Export of LEU to the Philippines); Issuances of Atomic Safety and Licensing Appeal Boards--Duke Power Company (Amendment to Materials License SNM-1773--Transportation of Spent Fuel from Oconee Nuclear Station for Storage at McGuire Nuclear Station); Issuances of the Atomic Safety Licensing Boards--Commonwealth Edison Company (Byron Station, Units 1 and 2), Dairyland Power Cooperative (La Crosse Boiling Water Reactor, Operating License and Show Cause), Florida Power and Light Company (St. Lucie Plant, Unit No. 2), Florida Power and Light Company (Turkey Point Nuclear Generating, Units 3 and 4), Metropolitan Edison Company (Three Mile Island Nuclear Station, Unit 1) Pacific Gas and Electric Company (Diablo Canyon Nuclear Power Plant, Units 1 and 2), The Regents of the University of California (UCLA Research Reactor), The Toledo Edison Company, et al. (Davis-Besse Nuclear Power Station, Units 2 and 3: Terminiation of Proceedings); Issuances of the Directors Denial--Florida Power and Light Company

  6. An Internationally Intelligible Principle: Comparing the Nondelegation Doctrine in the United States and European Union

    Directory of Open Access Journals (Sweden)

    Grodin Edward

    2015-11-01

    Full Text Available This article analyzes the degree of convergence between the United States and the European Union regarding the structural role of administrative agencies. As will be argued, the United States and European Union have arrived at the same broad conclusion about a “nondelegation doctrine”: delegations to administrative agencies should be permitted so long as some limiting principle governs the exercise of that power and allows for sufficient judicial review. However, the Supreme Court has taken a more permissive approach than the Court of Justice in defining the limiting principle. The United States has loosened the reins for the sake of modern administration while the European Union has maintained a firmer grip to keep better control over the Europeanization project. Stated another way, the nondelegation doctrine is simply a reflection of the systems’ relative levels of integration. Thus, the nondelegation doctrine will be stretched in Europe as functional regulatory demands arise from wider and deeper integration. At the same time, the focus will be redirected from substantive limits to procedural controls; accordingly, this Note advocates for a European Administrative Procedure Act.

  7. Superfund Record of Decision (EPA Region 6): United Nuclear Corporation, Mckinley County, New Mexico, ground-water operable unit (first remedial action) September 1988

    International Nuclear Information System (INIS)

    1988-01-01

    The United Nuclear Corporation (UNC) site is located approximately 17 miles northeast of Gallup, New Mexico in McKinley County. The site operated as a State-licensed uranium mill facility from June 1977 to May 1982. It includes an ore-processing mill (about 25 acres) and an unlined tailings pond area (about 100 acres). In July 1979, approximately 23 million gallons of tailings and pond water were released to a nearby river as a result of a dam breach in the tailings pond area. The site damage was repaired; however, attention was focused on ground-water contamination resulting from tailings seepage. Nevertheless, the offsite migration of radionuclides and chemical constituents from uranium milling byproduct materials into the ground water, as well as to surface water and air, are still principal threats at the site. The remedial action will address onsite ground water contamination. Source control and onsite surface reclamation will be implemented under the direction of the Nuclear Regulatory Commission and integrated with this ground water operable unit. The primary contaminants of concern affecting the ground water are metals including arsenic, and radioactive substances including radium-226/228 and gross alpha. The selected remedial action for the site is included

  8. Issues, challenges, and approaches for risk-informed decommissioning in the United States

    International Nuclear Information System (INIS)

    Orlando, D.A.; Johnson, R.L.

    2005-01-01

    Full text: The U.S. Nuclear Regulatory Commission (US-NRC) is the principal Federal regulatory authority in the United States responsible for ensuring public health and safety from the civilian use of radioactive material. US-NRC staff has developed and implemented various risk-informed approaches for regulating and managing the remediation of contaminated sites. A risk-informed approach to regulating the decommissioning of nuclear facilities has been generally defined by the US-NRC staff as an approach to decision-making that uses risk insights as well as traditional considerations to focus regulator and licensee attention on decommissioning activities commensurate with their importance to health and safety. Ensuring that decommissioning is carried out using a risk-informed approach should improve the focus on safety in decommissioning, improve the effectiveness, efficiency, and realism in regulatory decisions, and reduce unnecessary regulatory burden, and cost, on licensees. This paper summarizes the efforts by the US-NRC to develop and implement risk-informed approaches to the remediation of nuclear facilities in the United States. It also discusses the issues and challenges encountered by the US-NRC in attempting to implement a risk-informed approach to decommissioning. The US-NRC has been incrementally implementing its existing risk-informed and performance-based approach as it has completed its decommissioning regulations, guidance and other tools over the past several years. The principal challenge for US-NRC is implementing the existing risk-informed approach at specific sites in a manner that maintains safety, reduces costs, and enhances public understanding of the US-NRC's approach. In addition, effectively communicating how the US-NRC approaches are risk-informed and performance-based; ensuring that licensees understand, and take advantage of, the flexibility in meeting the decommissioning goals; ensuring that licensees and staff are aware of the

  9. Technical Specifications, Seabrook Station, Unit 1 (Docket No. 50-443): Appendix ''A'' to License No. NPF-67

    International Nuclear Information System (INIS)

    1989-05-01

    The Seabrook Station, Unit 1 Technical Specifications were prepared by the US Nuclear Regulatory Commission to set forth the limits, operating conditions, and other requirements applicable to a nuclear reactor facility as set forth in Section 50.36 of 10 CFR Part 50 for the protection of the health and safety of the public

  10. Geochemical characteristics of Holocene laminated sapropel (unit II) and underlying lacustrine unit III in the Black Sea

    Science.gov (United States)

    Dean, Walter E.; Arthur, Michael A.

    2011-01-01

    eg 1 of the 1988 R/V Knorr expeditions to the Black Sea recovered 90 gravity and box cores. The longest recovery by gravity cores was about 3 meters, with an average of about 2.5 meters, recovering all of the Holocene and upper Pleistocene sections in the Black Sea. During the latest Pleistocene glaciation, sea level dropped below the 35-meters-deep Bosporus outlet sill of the Black Sea. Therefore throughout most of its history the Black Sea was a lake, and most of its sediments are lacustrine. The oldest sediments recovered (older than 8,000 calendar years) consist of massive to coarsely banded lacustrine calcareous clay designated as lithologic Unit III, generally containing less than 1 percent organic carbon (OC). The base of overlying Unit II marks the first incursion of Mediterranean seawater into the Black Sea, and the onset of bottom-water anoxia about 7,900 calendar years. Unit II contains as much as 15 percent OC in cores from the deepest part of the Black Sea (2,200 meters). The calcium carbonate (CaCO3) remains of the coccolith Emiliania huxleyi form the distinctive white laminae of overlying Unit I. The composition of Unit III and Unit II sediments are quite different, reflecting different terrigenous clastic sources and increased contributions from hydrogenous and biogenic components in anoxic Unit II sapropel. In Unit II, positive covariance between OC and three trace elements commonly concentrated in OC-rich sediments where sulfate reduction has occurred (molybdenum, nickel, and vanadium) and a nutrient (phosphorus) suggest a large marine source for these elements although nickel and vanadium also have a large terrigenous clastic source. The marine sources may be biogenic or hydrogenous. A large biogenic source is also suggested for copper and cobalt. Because abundant pyrite forms in the water column and sediments of the Black Sea, we expected to find a large hydrogenous iron component, but a strong covariance of iron with aluminum suggests that the

  11. Imagine There's No Carnegie Unit

    Science.gov (United States)

    Klevgaard, Janine

    2013-01-01

    This article describes how the Alberta Education High School Flexibility Enhancement Pilot Project allowed 16 high schools in Alberta, Canada, to remove the restrictions of the Carnegie unit, the seat time per credit requirement that has been widely used since 1906. The two purposes of the project were to determine whether the Carnegie unit should…

  12. Seasonal unit roots in trade variables

    OpenAIRE

    Carol Alexander; Manuel Cantavella Jordá

    1997-01-01

    In this paper we examine the presence of seasonal unit roots in trade variables for Germany, France, the United Kingdom, and Italy, using the procedure developed by Hylleberg, Engle, Granger, and Yoo (1990) [HEGY]. Both quarterly and monthly data reject the presence of unit roots at most seasonal frequencies, more frequently in quarterly than in monthly data. This has important implications for econometric modeling of trade balance, exchange rates and income in European Union (EU) countries. ...

  13. Semi-automatic film processing unit

    International Nuclear Information System (INIS)

    Mohamad Annuar Assadat Husain; Abdul Aziz Bin Ramli; Mohd Khalid Matori

    2005-01-01

    The design concept applied in the development of an semi-automatic film processing unit needs creativity and user support in channelling the required information to select materials and operation system that suit the design produced. Low cost and efficient operation are the challenges that need to be faced abreast with the fast technology advancement. In producing this processing unit, there are few elements which need to be considered in order to produce high quality image. Consistent movement and correct time coordination for developing and drying are a few elements which need to be controlled. Other elements which need serious attentions are temperature, liquid density and the amount of time for the chemical liquids to react. Subsequent chemical reaction that take place will cause the liquid chemical to age and this will adversely affect the quality of image produced. This unit is also equipped with liquid chemical drainage system and disposal chemical tank. This unit would be useful in GP clinics especially in rural area which practice manual system for developing and require low operational cost. (Author)

  14. National legislative and regulatory activities

    International Nuclear Information System (INIS)

    2012-01-01

    This section gathers the following national legislative and regulatory activities sorted by country: Bulgaria: General legislation; Czech Republic: General legislation; France: General legislation, Regulatory infrastructure and activity; Germany: General legislation; India: Liability and compensation, Organisation and structure; Ireland: Radiation protection, General legislation; Korea (Republic of): Organisation and structure; Lithuania: Regulatory infrastructure and activity, Radioactive waste management, Radiation protection, international cooperation, Nuclear safety; Poland: General legislation; Romania: Environmental protection; Russian Federation: Radioactive waste management; Slovenia: Nuclear safety; Spain: Liability and compensation, Nuclear security; Sweden: Nuclear safety; Turkey: Radiation protection, Regulatory infrastructure and activity, Nuclear safety, Liability and compensation; United States: General legislation

  15. SI units for radiation measurements : for or against

    International Nuclear Information System (INIS)

    Nagaratnam, A.; Reddy, A.R.

    1975-01-01

    The historical evolution of the International System of Units (SI) is traced and concepts regarding radiation quantities and units as given by the ICRU are presented. Implications of the changeover to SI units for radiation measurement from the conventional system of familiar units like curie, roentgen, rad and rem are discussed. The familiar units will be kept for the time being along with SI units. In order to avoid confusion in the changeover period, new names, namely, becquerel and gray have been suggested by the authors for the SI units for activity and absorbed dose respectively. One becquerel will be 1 nuclear transformation per second and is approximately equal to 2.703 x 10 -11 Ci. One gray will be 1 joule per kilogram and is exactly equal to 100 rad. (M.G.B.)

  16. Regulating mobile advertising in the European Union and the United States

    DEFF Research Database (Denmark)

    Cleff, Evelyne Beatrix

    2008-01-01

    Mobile advertising is a gradually developing component of the marketing mix that includes advertisements directed to or accessed on consumers' mobile devices. Growing concerns about the protection of the consumers' personal data are being raised since mobile advertising may become an extremely...... for mobile advertising purposes while also examining the effectiveness of each of these approaches....... intrusive practice in an intimate personal space. Approaches of protecting the consumers' personal information differ greatly throughout the world. This article contrasts the regulatory environment in the European Union and in the United States applicable to the consumer's privacy and personal data used...

  17. UnitedHealth Group

    Science.gov (United States)

    UnitedHealth Group provides accessible and affordable services, improved quality of care, coordinated health care efforts, and a supportive environment for shared decision making between patients and their physicians.

  18. Field demonstrations of radon adsorption units

    International Nuclear Information System (INIS)

    Abrams, R.F.

    1989-01-01

    Four radon gas removal units have been installed in homes in the Northeast U.S. These units utilize dynamic adsorption of the radon gas onto activated charcoal to remove the radon from room air. Two beds of charcoal are used so that one bed removes radon while the second bed is regenerated using outdoor air in a unique process. The beds reverse at the end of a predetermined cycle time, providing continuous removal of radon from the room air. The process and units have undergone extensive development work in the laboratory as well as in homes and a summary of this work is discussed. This work showed that the system performs very effectively over a range of operating conditions similar to those found in a home. The field test data that is presented shows that scale up from the laboratory work was without problem and the units are functioning as expected. This unit provides homeowners and mitigation contractors with another option to solve the radon gas problem in homes, particularly in homes that it is difficult to prevent radon from entering

  19. Nuclear power in the United Arab Emirates: Legal framework and regulatory cooperation

    International Nuclear Information System (INIS)

    Vasquez-Maignan, X.

    2012-01-01

    As part of a decision to diversify its energy mix, the United Arab Emirates (UAE) has begun construction of its first nuclear power plant. In that context, it has also taken a number of important steps to integrate itself into the international regime for nuclear safety: adoption of the UAE's Federal Law No. 6 of 2009 on the peaceful uses of nuclear energy, establishment of the Federal Authority for Nuclear Regulation (FANR), establishment of the Emirates Nuclear Energy Corporation (ENEC), awarding of the first contract for nuclear power plants in the UAE, etc. The UAE nuclear liability regime is then presented, with details on the basic principles that form the foundation of the nuclear liability conventions, followed by the participation of the FANR in the Multinational Design Evaluation Programme (MDEP) in September 2012

  20. Breakwater stability with damaged single layer armour units

    OpenAIRE

    De Rover, R.; Verhagen, H.J.; Van den Berge, A.; Reedijk, B.

    2008-01-01

    The effect of single layer interlocking armour unit breakage on the hydraulic armour layer stability and potential damage progression is addressed in this paper. A 2-dimensional scale model of a rubble mound breakwater with an armour layer consisting of Xbloc armour units was tested. The residual armour layer stability with broken units was determined. The armour unit displacement and damage progression was assessed. According to the test series breakage of the single layer armour units has a...

  1. 21 CFR 890.5950 - Powered heating unit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered heating unit. 890.5950 Section 890.5950...) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5950 Powered heating unit. (a) Identification. A powered heating unit is a device intended for medical purposes that...

  2. Safety evaluation report related to the operation of Diablo Canyon Nuclear Power Plant, Units 1 and 2 (Docket Nos. 50-275 and 50-323)

    International Nuclear Information System (INIS)

    1983-12-01

    Supplement 20 to the Safety Evaluation Report for Pacific Gas and Electric Company's application for licenses to operate Diablo Canyon Nuclear Power Plant, Unit 1 and Unit 2 (Docket Nos. 50-275 and 50-323), has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. This supplement reports on the verification effort for Diablo Canyon Unit 1 that was performed between November 1981 and the present in response to Commission Order CLI-81-30 and an NRC letter of November 19, 1981 to the licensee. Specifically, Supplement 20 addresses those issues and other matters identified in Supplements 18 and 19 that must be resolved prior to Unit 1 achieving criticality and operating at power levels up to 5% of rated full power. This SER Supplement applies only to Diablo Canyon Unit 1

  3. 75 FR 6223 - PSEG Nuclear LLC; Hope Creek Generating Station and Salem Nuclear Generating Station, Unit Nos. 1...

    Science.gov (United States)

    2010-02-08

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-272, 50-311 and 50-354; NRC-2010-0043] PSEG Nuclear LLC; Hope Creek Generating Station and Salem Nuclear Generating Station, Unit Nos. 1 and 2...-70, and DPR-75, issued to PSEG Nuclear LLC (PSEG, the licensee), for operation of the Hope Creek...

  4. Portable brine evaporator unit, process, and system

    Science.gov (United States)

    Hart, Paul John; Miller, Bruce G.; Wincek, Ronald T.; Decker, Glenn E.; Johnson, David K.

    2009-04-07

    The present invention discloses a comprehensive, efficient, and cost effective portable evaporator unit, method, and system for the treatment of brine. The evaporator unit, method, and system require a pretreatment process that removes heavy metals, crude oil, and other contaminates in preparation for the evaporator unit. The pretreatment and the evaporator unit, method, and system process metals and brine at the site where they are generated (the well site). Thus, saving significant money to producers who can avoid present and future increases in transportation costs.

  5. Understanding nursing units with data and theory.

    Science.gov (United States)

    Diers, Donna; Hendrickson, Karrie; Rimar, Joan; Donovan, Donna

    2013-01-01

    Nursing units are social systems whose function depends on many variables. Available nursing data, combined with a theory of organizational diagnosis, can be used to understand nursing unit performance. One troubled unit served as a case study in organizational diagnosis and treatment using modern methods of data mining and performance improvement. Systems theory did not prescribe how to fix an underbounded system. The theory did suggest, however, that addressing the characteristics of overbounded and underbounded systems can provide some order and structure and identify helpful resources. In this instance, the data analysis served to help define the unit's problems in conjunction with information gained from talking with the nurses and touring the unit, but it was the theory that gave hints for direction for change.

  6. Audit of Wolf Creek Generating Station, Unit 1 technical specifications. Final technical evaluation report

    International Nuclear Information System (INIS)

    Stromberg, H.M.

    1985-07-01

    This document was prepared for the Nuclear Regulatory Commission (NRC) to assist them in determining whether the Wolf Creek Generating Station Unit 1 Technical Specifications (T/S), which govern plant systems configurations and operations, are in conformance with the assumptions of the Final Safety Analysis Report (FSAR) as amended, the requirements of the Safety Evaluation Report (SER) as supplemented, and the Comments and Responses to the Wolf Creek Technical Specification Draft Inspection Report. A comparative audit of the FSAR as amended, the SER as supplemented, and the Draft Inspection Report was performed with the Wolf Creek T/S. Several discrepancies were identified and subsequently resolved through discussions with the cognizant NRC reviewer, NRC staff reviewers and/or utility representatives. The Wolf Creek Generating Station Unit 1 T/S, to the extent reviewed, are in conformance with the FSAR, SER, and Draft Inspection Report

  7. Tax Unit Boundaries

    Data.gov (United States)

    Kansas Data Access and Support Center — The Statewide GIS Tax Unit boundary file was created through a collaborative partnership between the State of Kansas Department of Revenue Property Valuation...

  8. Coordinator, Evaluation Unit | IDRC - International Development ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Job Summary The Evaluation Unit Coordinator is expected to: ... with Centre policies and procedures and disseminates information to Unit staff on changes ... Coordinates the planning and organization of technical and administrative meetings ...

  9. United Kingdom electric system privatization

    Energy Technology Data Exchange (ETDEWEB)

    Lolli, A. (Bologna Univ. (Italy))

    1992-03-01

    This paper reviews the mechanics and first results of deregulation in the electric power industry of the United Kingdom. Several aspects are dealt with, namely: 1983 Energy Act impacts on ownership and subsequent changes brought about by the 1989 Energy Act; the Act's stipulations with regard to share acquisition and distribution; the division of the patrimony of the Area Boards; natural monopolistic characteristics of power distribution; vertical integration in Scotland, target investment limits in Government and public participation; the 'golden share' concept to guarantee public participation; current 40% share ownership by the Government; 15% private ownership limit for individual investors; external control by Government of licensing and rate structure setting; the impacts of organizational changes on the overall cost benefits of deregulation; modified Governmental regulatory powers; measures to ensure competition and consumer protection; provisions regarding misbehaviour; second tier suppliers and reserve fuel supply obligations; deregulation impacts on nuclear power marketing; power pooling regulations; installation of new transmission lines; provisions encouraging the use of diverse energy sources; franchising; interconnection with national grid; regulation of technical operations; standby as it affects rate structure; and spot market pricing.

  10. 75 FR 75704 - Pacific Gas and Electric Company (Diablo Canyon Nuclear Power Plant, Units 1 And 2); Notice of...

    Science.gov (United States)

    2010-12-06

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-275-LR; 50-323-LR] Pacific Gas and Electric Company (Diablo Canyon Nuclear Power Plant, Units 1 And 2); Notice of Appointment of Adjudicatory Employee... Seismologist, Office of Nuclear Material Safety and Safeguards, has been appointed as a Commission adjudicatory...

  11. 40 CFR 160.35 - Quality assurance unit.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Quality assurance unit. 160.35 Section... LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.35 Quality assurance unit. (a) A testing facility shall have a quality assurance unit which shall be responsible for monitoring each study to assure...

  12. 21 CFR 58.35 - Quality assurance unit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Quality assurance unit. 58.35 Section 58.35 Food... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.35 Quality assurance unit. (a) A testing facility shall have a quality assurance unit which shall be responsible for...

  13. Ecological units of the Northern Region: Subsections

    Science.gov (United States)

    John A. Nesser; Gary L. Ford; C. Lee Maynard; Debbie Dumroese

    1997-01-01

    Ecological units are described at the subsection level of the Forest Service National Hierarchical Framework of Ecological Units. A total of 91 subsections are delineated on the 1996 map "Ecological Units of the Northern Region: Subsections," based on physical and biological criteria. This document consists of descriptions of the climate, geomorphology,...

  14. 31 CFR 515.334 - United States national.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States national. 515.334 Section 515.334 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE... of the United States, and which has its principal place of business in the United States. [61 FR...

  15. 24 CFR 990.140 - Occupied dwelling units.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Occupied dwelling units. 990.140 Section 990.140 Housing and Urban Development Regulations Relating to Housing and Urban Development... Eligible Unit Months § 990.140 Occupied dwelling units. A PHA is eligible to receive operating subsidy for...

  16. 7 CFR 1220.615 - State and United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false State and United States. 1220.615 Section 1220.615... CONSUMER INFORMATION Procedures To Request a Referendum Definitions § 1220.615 State and United States. State and United States include the 50 States of the United States of America, the District of Columbia...

  17. 7 CFR 1220.129 - State and United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false State and United States. 1220.129 Section 1220.129... CONSUMER INFORMATION Soybean Promotion and Research Order Definitions § 1220.129 State and United States. The terms State and United States include the 50 States of the United States of America, the District...

  18. 7 CFR 1212.32 - United States Customs Service.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States Customs Service. 1212.32 Section 1212... § 1212.32 United States Customs Service. “United States Customs Service” or “Customs” means the United States Customs and Border Protection, an agency of the Department of Homeland Security. Honey Packers and...

  19. Nuclear Regulatory Commission Issuances, May 81

    International Nuclear Information System (INIS)

    1981-05-01

    Contents: Issuances of the Nuclear Regulatory Commission--Consolidated Edison Company of New York, Inc. (Indian Point, Unit No. 2), Power Authority of the State of New York (Indian Point, No. 3 Nuclear Power Plant), Pacific Gas and Electric Company (Diablo Canyon Nuclear Power Plant, Units 1 and 2), Statement of Policy on Conduct of Licensing Proceedings, Uranium Mill Licensing Requirements; Issuances of Atomic Safety and Licensing Appeal Boards--Houston Lighting and Power Company, et al. (South Texas Project, Units 1 and 2), Metropolitan Edison Company, et al. (Three Mile Island Nuclear Station, Unit No. 2), Pennsylvania Power and Light Company and Allegheny Electric Cooperative, Inc. (Susquehanna Steam Electric Station, Units 1 and 2), Philadelphia Electric Company et al. (Peach Bottom Atomic Power Station, Units 2 and 3), Public Service Electric and Gas Company (Hope Creek Generating Station, Units 1 and 2); Issuances of the Atomic Safety and Licensing Boards--Duke Power Company (William B. McGuire Nuclear Station, Units 1 and 2), Florida Light and Power Company (Turkey Point Nuclear Generating, Units 3 and 4), Illinois Power Company, et al. (Clinton Power Station, Units 1 and 2), Sacramento Municipal Utility District (Rancho Seco Nuclear Generating Station); Issuances of the Directors Denial--Commonwealth Edison Company (Byron Station, Units 1 and 2), Consolidated Edison Company of New York, Inc. (Indian Point Unit No. 2), Gulf States Utilities Company (River Bend Station Units 1 and 2), Petition to Suspend All Operating Licenses for Pressurized Water Reactors (River Bend Station Units 1 and 2), Portland General Electric Company (Trojan Nuclear

  20. Order units in a C-algebra

    Indian Academy of Sciences (India)

    Abstract. Order unit property of a positive element in a *-algebra is defined. It is proved that precisely projections satisfy this order theoretic property. This way, unital hereditary *-subalgebras of a *-algebra are characterized.