WorldWideScience

Sample records for unit protocol converter

  1. Converter Monitoring Unit for Retrofit of Wind Power Converters

    DEFF Research Database (Denmark)

    Rannestad, Bjorn; Maarbjerg, Anders Eggert; Frederiksen, Kristian

    2018-01-01

    A Converter Monitoring Unit (CMU), which will enable condition monitoring of wind turbine converters is presented in this paper. Reducing the cost of corrective maintenance by means of condition monitoring is a way of lowering Operation & Maintenance (O&M) costs for wind turbine systems....... The CMU must be able to detect a broad range of failure modes related to Insulated Gate Bipolar Transistor (IGBT) power modules and associated gate drives. IGBT collector-emitter on-state voltage (vceon) and current (ic) is sampled in the CMU and used for detection of emerging failures. A new method...... for compensation of unwanted inductive voltage drop in the vceon measurement path is presented, enabling retrofitting of CMUs in existing wind turbines. Finally, experimental results obtained on a prototype CMU are presented. Experimentally the vceon dependency to IGBT junction temperature and deterioration...

  2. A VXI-GPIB protocol converter based on DSP

    International Nuclear Information System (INIS)

    Hu Yuanfeng; Yu Xiaoqi; Lu Jingping

    2006-01-01

    A VXI-GPIB protocol converter based on DSP is introduced. The word-serial protocol with the message-based interface is implemented by EPLD and DSP. The GPIB functions are implemented by programming to the GPIB control chip. The transfer from VXI messages to GPIB functions is implemented by DSP. As an example of application, the control functions for oscilloscopes have been implemented in a VXI-GPIB heterogeneous system using such modules. (authors)

  3. Protocol converter for serial communication between digital rectifier controllers and a power plant SCADA system

    Directory of Open Access Journals (Sweden)

    Vukić Vladimir Đ.

    2016-01-01

    Full Text Available The paper describes the protocol converter INT-485-MBRTU, developed for serial communication between the thyristor rectifier (based on the proprietary protocol "INT-CPD-05", according to standard RS-485 and the SCADA system (based on protocol "Modbus RTU", of the same standard in the thermal power plant "Nikola Tesla B1". Elementary data on industrial communication protocols and communication gateways were provided. The basic technical characteristics of the "Omron" programmable logic controller CJ series were described, as well as the developed device INT-485-MBRTU. Protocol converters with two versions of communication software were tested, differing only in one control word, intended for a forced successive change of communication sequences, in opposite to automatic sequence relieve. The device iNT-485-MBRTU, with the program for forced successive change of communication sequences, demonstrated the reliability of data transfer of 100 %, in a sample of approximately 480 messages. For nearly the same sample, the same protocol converter, with a version of the program without any type of message identifiers, transferred less than 60 % of the foreseen data. During multiple sixty-hour tests, the reliability of data transfer of at least 99.9979% was recorded, in 100% of the analysed cases, and for a sample of nearly 96,000 pairs of the send and receive messages. We analysed the results and estimated the additional possibilities for application of the INT-485-MBRTU protocol converter.

  4. Dynamic optimization of a FCC converter unit: numerical analysis

    Directory of Open Access Journals (Sweden)

    E. Almeida Nt

    2011-03-01

    Full Text Available Fluidized-bed Catalytic Cracking (FCC is a process subject to frequent variations in the operating conditions (including feed quality and feed rate. The production objectives usually are the maximization of LPG and gasoline production. This fact makes the FCC converter unit an excellent opportunity for real-time optimization. The present work aims to apply a dynamic optimization in an industrial FCC converter unit, using a mechanistic dynamic model, and to carry out a numerical analysis of the solution procedure. A simultaneous approach was used to discretize the system of differential-algebraic equations and the resulting large-scale NLP problem was solved using the IPOPT solver. This study also does a short comparison between the results obtained by a potential dynamic real-time optimization (DRTO against a possible steady-state real-time optimization (RTO application. The results demonstrate that the application of dynamic real-time optimization of a FCC converter unit can bring significant benefits in production.

  5. Inhibition of angiotensin-converting enzyme increases oestradiol production in ewes submitted to oestrous synchronization protocol.

    Science.gov (United States)

    Costa, A s; Junior, A S; Viana, G E N; Muratori, M C S; Reis, A M; Costa, A P R

    2014-10-01

    This study aimed at evaluating the effects of angiotensin-converting enzyme inhibitor (enalapril) and angiotensin II antagonist (valsartan) on the oestradiol and progesterone production in ewes submitted to oestrous synchronization protocol. The animals were weighed and randomly divided into three groups (n = 7). A pre-experiment conducted to verify the effectiveness and toxicity of enalapril (0.5 mg/kg LW) and valsartan (2.2 mg/kg LW) showed that, in the doses used, these drugs were effective in reducing blood pressure without producing toxic effects. In the experiment, all animals were subjected to oestrous synchronization protocol during 12 days. On D10, D11 and D12, animals received saline, enalapril or valsartan (same doses of the pre-experiment), according to the group randomly divided. The hormonal analysis showed an increase in oestradiol on the last day of the protocol (D12) in animals that received enalapril (p progesterone in any of the treatments. It is concluded that valsartan and enalapril are safe and effective subcutaneously for use in sheep and that the angiotensin-converting enzyme (ACE) inhibition with enalapril leads to an increase in oestradiol production near ovulation without changing the concentration of progesterone. This shows that ACE inhibition may be a useful tool in reproductive biotechnologies involving induction and synchronization of oestrus and ovulation in sheep. © 2014 Blackwell Verlag GmbH.

  6. Grid support by power electronic converters of distributed generation units

    NARCIS (Netherlands)

    Morren, J.

    2006-01-01

    An increasing number of small Distributed Generation (DG) units are connected to the grid. The introduction of DG causes several problems, which are mainly related to the differences between DG units and conventional generators. Four problems have been considered in this thesis: damping of

  7. Impact of distributed generation units with power electronic converters on distribution network protection

    NARCIS (Netherlands)

    Morren, J.; Haan, de S.W.H.

    2008-01-01

    An increasing number of distributed generation units (DG units) are connected to the distribution network. These generators affect the operation and coordination of the distribution network protection. The influence from DG units that are coupled to the network with a power electronic converter

  8. Design of master control unit for laboratory prototype of traction converter for locomotives

    OpenAIRE

    Žák, Jan; Peroutka, Zdeněk; Ovaska, Seppo J.

    2008-01-01

    This paper deals with the prototype of a main traction converter with medium-frequency transformer for AC trolley wire-fed locomotives. The attention is paid to the new master control and diagnostic unit. The designed master control unit has been implemented in the LabVIEW environment. Our master control unit ensures an effective human interface between a user and the control hardware. In this case, the master unit makes possible both extensive control and diagnostic operations of the laborat...

  9. Implementation of enteral feeding protocol in an intensive care unit

    DEFF Research Database (Denmark)

    Padar, Martin; Uusvel, Gerli; Starkopf, Liis

    2017-01-01

    AIM: To determine the effects of implementing an enteral feeding protocol on the nutritional delivery and outcomes of intensive care patients. METHODS: An uncontrolled, observational before-and-after study was performed in a tertiary mixed medical-surgical intensive care unit (ICU). In 2013......, a nurse-driven enteral feeding protocol was developed and implemented in the ICU. Nutrition and outcome-related data from patients who were treated in the study unit from 2011-2012 (the Before group) and 2014-2015 (the After group) were obtained from a local electronic database, the national Population...... the groups. Patients in the After group had a lower 90-d (P = 0.026) and 120-d (P = 0.033) mortality. In the After group, enteral nutrition was prescribed less frequently (P = 0.039) on day 1 but significantly more frequently on all days from day 3. Implementation of the feeding protocol resulted in a higher...

  10. Deadbeat control of power leveling unit with bidirectional buck/boost DC/DC converter

    OpenAIRE

    Hamasaki, Shin-ichi; Mukai, Ryosuke; Yano, Yoshihiro; Tsuji, Mineo

    2014-01-01

    As a distributed generation system increases, a stable power supply becomes difficult. Thus control of power leveling (PL) unit is required to maintain the balance of power flow for irregular power generation. The unit is required to respond to change of voltage and bidirectional power flow. So the bidirectional buck/boost DC/DC converter is applied for the control of PL unit in this research. The PL unit with Electric double-layer capacitor (EDLC) is able to absorb change of power, and it is...

  11. Experience in the installation of a microprocessor system for controlling converter units of the Vyborg substation

    International Nuclear Information System (INIS)

    Gusakovskii, K. B.; Zmaznov, E. Yu.; Katantsev, S. V.; Mazurenko, A. K.; Mestergazi, V. A.; Prochan, G. G.; Funtikova, S. F.

    2006-01-01

    The experience in the installation of modern digital systems for controlling converter units at the Vyborg converter substation on the basis of advanced microprocessor devices is considered. It is shown that debugging of a control and protection system on mathematical and physical models does not guarantee optimum control of actual converter devices. Examples of advancing the control and protection system are described, the necessity for which has become obvious in tests of actual equipment. Comparison of oscillograms of processes before optimization of the control system and after its optimization and adjustment shows that the digital control system makes it possible to improve substantially the algorithms of control and protection in the short term and without changing the hardware component

  12. Enhanced static ground power unit based on flying capacitor based h-bridge hybrid active-neutral-point-clamped converter

    DEFF Research Database (Denmark)

    Abarzadeh, Mostafa; Madadi Kojabadi, Hossein; Deng, Fujin

    2016-01-01

    Static power converters have various applications, such as static ground power units (GPUs) for airplanes. This study proposes a new configuration of a static GPU based on a novel nine-level flying capacitor h-bridge active-neutral-point-clamped (FCHB_ANPC) converter. The main advantages of the p......Static power converters have various applications, such as static ground power units (GPUs) for airplanes. This study proposes a new configuration of a static GPU based on a novel nine-level flying capacitor h-bridge active-neutral-point-clamped (FCHB_ANPC) converter. The main advantages...

  13. The harmonic composition of the output voltage of a rectifier unit with a PWM voltage booster converter.

    OpenAIRE

    ПАНЧЕНКО, В В

    2015-01-01

    The author investigates a rectifier unit constructed on the basis of cascade connection of the main non-controlled m-pulse rectifier and PWM voltage booster converter. The research presents the analysis of the harmonic composition of the output voltage of a rectifier unit with a PWM voltage booster converter on completely controlled keys. The dependence of the relative harmonic amplitude on the commutation corner is defined. The estimation of a rectifier unit electromagnetic compatibility wit...

  14. Economics of superconductive energy storage inductor-converter units in power systems

    International Nuclear Information System (INIS)

    Yadavalli, S.R.

    1975-01-01

    Since the original proposal by Boom and Peterson in 1972, there has been growing interest in superconductive energy storage inductor converter units (IC units) for use in large power systems for peak shaving and load leveling. Different aspects of it are being studied at the University of Wisconsin and elsewhere. An economic study of such IC units shows that large IC units, bigger than about 1000 MWh, are economically competitive with other peaking alternatives, larger units being more economical. External electrical circuit losses in IC units have negligible effect on their storage and power capacities. There are three credits which could be of significant economic value to IC units. These are: (1) transmission credit which varied from about $4 to $60/kW peak power, with a typical value of about $35/kW; (2) pollution credit which varied from about $5 to $160/kW with a typical value of $80/kW; and Spinning Reserve Credit which varied from about $20 to $370/kW with a typical value of $90/kW

  15. Data acquisition and meter unit based in wifi communication protocol

    Directory of Open Access Journals (Sweden)

    Gerardo Cázarez Ayala

    2012-05-01

    Full Text Available Without doubt, the competitive fast rhythm of the industries is one of the main causes helped bring to the accelerated growth of the electronic technology and the communication. The need to develop new products with a best quality, cheaper and faster as assure and increase the quality of the products in the international markets, requires of new technologies to the metering, monitoring and control of their production processes, of which finality is to improve the processes to guaranteed their products in the market in the less time possible, the best quality and low cost for the final consumer. This work is based in the design and implementation of a Wireless Data Acquisition Unit based in WiFi protocol, which is oriented to meter, monitoring and the control of processes in the industry, commercial and the home automation applications, using one of the wirelessprotocols with the biggest acceptance in the market, with the main objective of to take advantage of the installed physical infrastructure in the place of the application, like industry, company or house. The Unit is based in the RN-131G, a Roving Network company module, which is able to work in stand-alone mode with ultralow power consummation and supporting the IEEE 802.11b/g protocols, in which is possible to achieve transfer rates of up to 11 Mbps and 54 Mbps in /b & /g specifications respectively. Whit this unit is possible to meter up to 5 analogs signals with 14 bits precision and has include a temperature and relative humidity sensors. This unit can meter two digital signals and act mean two digitals outputs, and gas include an USB port for communication and programming tasks.

  16. Electric strength of metal-ceramic brazed units of thermionic energy converters in cesium vapours

    International Nuclear Information System (INIS)

    Belousenko, A.P.; Vasilchenko, A.V.; Nikolaev, Y.V.

    1989-01-01

    The investigation of electric strength characteristics of the hollow metal-ceramic brazed units of thermionic energy converters with the insulator 1 = 10-50 mm from polycrystal aluminum oxide at the temperature T = 450-750 degrees and the cesium vapour pressure P Cs = 10 - 1 -10 3 Pa has been carried out. The experimental dependencies of the break-down voltage of the brazed units on the temperature, parameter P Cs · 1 and the value of surface electric resistance of the insulators are given as well as the empiric equations obtained with the help of experimental data for calculating the break-down voltage. A mechanism of ceramic insulator influence on electric strength characteristics of the cesium gap is investigated. A breakdown model explaining this influence is proposed

  17. MASMA: a versatile multifunctional unit (gated window amplifier, analog memory, and height-to-time converter)

    International Nuclear Information System (INIS)

    Goursky, V.; Thenes, P.

    1969-01-01

    This multipurpose unit is designed to accomplish one of the following functions: - gated window amplifier, - Analog memory and - Amplitude-to-time converter. The first function is mainly devoted to improve the poor resolution of pulse-height analyzers with a small number of channels. The analog memory, a new function in the standard range of plug-in modules, is capable of performing a number of operations: 1) fixed delay, or variable delay dependent on an external parameter (application to the analog processing of non-coincident pulses), 2) de-randomiser to increase the efficiency of the pulse height analysis in a spectrometry experiment, 3) linear multiplexer to allow an analyser to serve as many spectrometry devices as memory elements that it possesses. Associated with a coding scaler, this unit, if used as a amplitude-to-time converter, constitutes a Wilkinson A.D.C with a capability of 10 bits (or more) and with a 100 MHz clock frequency. (authors) [fr

  18. Three Dimensional (3D) Printing: A Straightforward, User-Friendly Protocol to Convert Virtual Chemical Models to Real-Life Objects

    Science.gov (United States)

    Rossi, Sergio; Benaglia, Maurizio; Brenna, Davide; Porta, Riccardo; Orlandi, Manuel

    2015-01-01

    A simple procedure to convert protein data bank files (.pdb) into a stereolithography file (.stl) using VMD software (Virtual Molecular Dynamic) is reported. This tutorial allows generating, with a very simple protocol, three-dimensional customized structures that can be printed by a low-cost 3D-printer, and used for teaching chemical education…

  19. AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT V, AUTOMATIC TRANSMISSIONS--TORQUE CONVERTER.

    Science.gov (United States)

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF TORQUE CONVERTERS USED ON DIESEL POWERED VEHICLES. TOPICS ARE (1) FLUID COUPLINGS (LOCATION AND PURPOSE), (2) PRINCIPLES OF OPERATION, (3) TORQUE CONVERRS, (4) TORQMATIC CONVERTER, (5) THREE STAGE, THREE ELEMENT TORQUE CONVERTER, AND (6)…

  20. Logistical Impact Study of Photovoltaic Power Converter Technology to the United States Army and the United States Marine Corps

    National Research Council Canada - National Science Library

    Whiteker, James

    2004-01-01

    The purpose of this MBA Project was to analyze the logistical and fiscal impact of replacing selected disposable batteries with rechargeable batteries and photovoltaic power converter chargers within...

  1. A Review of Communications Protocol for Intelligent Remote Terminal Unit Development

    Directory of Open Access Journals (Sweden)

    Mohd Ruddin Ab. Ghani

    2013-11-01

    Full Text Available This paper reviewed all the possible interfacing communication protocols for remote terminal unit (RTU. Supervisory Control and Data Acquisition (SCADA system is a central station that can communicate with other network using the protocol. Fundamentally, the architectures of all networks are based on the seven layers of open system interconnection (OSI and International Standard Organization (ISO. The objective of designing the protocols is to check the status of all the input and output field devices and send the report according to that status. The corresponding protocol and communication parameters between the connecting devices will be included in designing a complex SCADA system. The available protocols to develop the communication of RTU are Modbus/ASCII, distributed network protocol (DNP3, controller area network (CAN, International Electro-technical Commission (IEC 60870, transmission control protocol/internet protocol (TCP/IP.

  2. Converting MMSE to MoCA and MoCA 5-minute protocol in an educationally heterogeneous sample with stroke or transient ischemic attack.

    Science.gov (United States)

    Wong, Adrian; Black, Sandra E; Yiu, Stanley Y P; Au, Lisa W C; Lau, Alexander Y L; Soo, Yannie O Y; Chan, Anne Y Y; Leung, Thomas W H; Wong, Lawrence K S; Kwok, Timothy C Y; Cheung, Theodore C K; Leung, Kam-Tat; Lam, Bonnie Y K; Kwan, Joseph S K; Mok, Vincent C T

    2018-05-01

    The Montreal Cognitive Assessment (MoCA) is psychometrically superior over the Mini-mental State Examination (MMSE) for cognitive screening in stroke or transient ischemic attack (TIA). It is free for clinical and research use. The objective of this study is to convert scores from the MMSE to MoCA and MoCA-5-minute protocol (MoCA-5 min) and to examine the ability of the converted scores in detecting cognitive impairment after stroke or TIA. A total of 904 patients were randomly divided into training (n = 623) and validation (n = 281) samples matched for demography and cognition. MMSE scores were converted to MoCA and MoCA-5 min using (1) equipercentile method with log-linear smoothing and (2) Poisson regression adjusting for age and education. Receiver operating characteristics curve analysis was used to examine the ability of the converted scores in differentiating patients with cognitive impairment. The mean education was 5.8 (SD = 4.6; ranged 0-20) years. The entire spectrum of MMSE scores was converted to MoCA and MoCA-5 min using equipercentile method. Relationship between MMSE and MoCA scores was confounded by age and education, and a conversion equation with adjustment for age and education was derived. In the validation sample, the converted scores differentiated cognitively impaired patients with area under receiver operating characteristics curve 0.826 to 0.859. We provided 2 methods to convert scores from the MMSE to MoCA and MoCA-5 min based on a large sample of patients with stroke or TIA having a wide range of education and cognitive levels. The converted scores differentiated patients with cognitive impairment after stroke or TIA with high accuracy. Copyright © 2018 John Wiley & Sons, Ltd.

  3. A Robust Open Ascending-price Multi-unit Auction Protocol against False-name Bids

    Science.gov (United States)

    Iwasaki, Atsushi; Yokoo, Makoto; Terada, Kenji

    This paper develops a new ascending-price multi-unit auction protocol that has following characteristics: (i) it has an open format, (ii) sincere bidding is an equilibrium strategy even if the marginal utilities of each agent can increase and agents can submit false-name bids. False-name bids are bids submitted under fictitious names such as multiple e-mail addresses, which can be done easily in the Internet. This is the first protocol that has these two characteristics. We show that our new protocol outperforms an existing protocol, which satisfies (ii), with respect to the social surplus and the seller's revenue.

  4. Robust Multi-unit Auction Protocol against False-name Bids

    Science.gov (United States)

    Yokoo, Makoto; Sakurai, Yuko; Matsubara, Shigeo

    This paper presents a new multi-unit auction protocol (IR protocol) that is robust against false-name bids. Internet auctions have become an integral part of Electronic Commerce and a promising field for applying agent and Artificial Intelligence technologies. Although the Internet provides an excellent infrastructure for executing auctions, the possibility of a new type of cheating called false-name bids has been pointed out. A false-name bid is a bid submitted under a fictitious name. A protocol called LDS has been developed for combinatorial auctions of multiple different items and has proven to be robust against false-name bids. Although we can modify the LDS protocol to handle multi-unit auctions, in which multiple units of an identical item are auctioned, the protocol is complicated and requires the auctioneer to carefully pre-determine the combination of bundles to obtain a high social surplus or revenue. For the auctioneer, our newly developed IR protocol is easier to use than the LDS, since the combination of bundles is automatically determined in a flexible manner according to the declared evaluation values of agents. The evaluation results show that the IR protocol can obtain a better social surplus than that obtained by the LDS protocol.

  5. The Kyoto Protocol and forestry practices in the United States

    Science.gov (United States)

    Bov B. Eav; Richard A. Birdsey; Linda S. Heath

    2000-01-01

    Forestry may play an important if not critical role in the ability of the U.S. to meet its greenhouse gas emissions target under the terms of the Kyoto Protocol. Given the low rate of change in the U.S. forest land area, the major anthropogenic influences on the current net forest carbon flux are forest management and protection activities that have resulted in...

  6. Proposal for the Award of a Contract for the Supply of the Power Units for LHC Thyristor Power Converters

    CERN Document Server

    2003-01-01

    This document concerns the award of a contract for the supply of 12 power units of thyristor power converters rated from 365 to 770 kW for the LHC. Following a market survey carried out among 98 firms in nineteen Member States, a call for tenders (IT-3003/SL/LHC) was sent on 25 October 2002 to six firms in four Member States. By the closing date, CERN had received five tenders from five firms in four Member States. The Finance Committee is invited to agree to the negotiation of a contract with OCEM (IT), the lowest bidder, for the supply of 12 power units of thyristor power converters for a total amount of 981 484 Swiss francs not subject to revision, with options for three additional units of the power part of thyristor power converters, for an additional amount of 249 681 Swiss francs, subject to revision for inflation from 1 August 2006, bringing the total amount to 1 231 165 Swiss francs. The firm has indicated the following distribution by country of the contract value covered by this adjudication propos...

  7. Converted vehicle for battery electric drive. Aspects on the design of the software-driven vehicle control unit

    Energy Technology Data Exchange (ETDEWEB)

    Giessler, Martin; Paul, Jens; Gauterin, Frank [Karlsruher Institut fuer Technologie (KIT), Karlsruhe (Germany). Inst. fuer Fahrzeugsystemtechnik (FAST); Fritz, Alexander; Sander, Oliver; Mueller-Glaser, Klaus D. [Karlsruher Institut fuer Technologie (KIT), Karlsruhe (Germany). Inst. fuer Technik der Informationsverarbeitung (ITIV)

    2012-11-01

    At the Karlsruher Institute of Technology (KIT) a vehicle was converted for full battery electric drive within a cooperation of several faculties under the direction of the chair of vehicle technology. Within this paper the developed software to control the main functions of the vehicle will be presented and potentials to increase the energy efficiency will be discussed. The software based vehicle control unit is the central control unit to realize drivers command with respect to the system parameters, which are important for safety, dynamics, range and comfort of the vehicle. The structure of the software architecture, the interaction with the main electric vehicle specific control units and components and the main implemented functions will be described within this paper. The converted vehicle consists mainly of one electric motor with water cooled power electronics that drives the front axle, 21 battery modules controlled and managed by the battery management system, one on board charging device and an universal control unit. Not only strategies for power recovery while braking, but also strategies for driving and operation can help increase the energy efficiency. Select measures to recover and safe energy are also shown. (orig.)

  8. Variability of United States Online Rehabilitation Protocols for Proximal Hamstring Tendon Repair

    Science.gov (United States)

    Lightsey, Harry M.; Kantrowitz, David E.; Swindell, Hasani W.; Trofa, David P.; Ahmad, Christopher S.; Lynch, T. Sean

    2018-01-01

    Background: The optimal postoperative rehabilitation protocol following repair of complete proximal hamstring tendon ruptures is the subject of ongoing investigation, with a need for more standardized regimens and evidence-based modalities. Purpose: To assess the variability across proximal hamstring tendon repair rehabilitation protocols published online by United States (US) orthopaedic teaching programs. Study Design: Cross-sectional study. Methods: Online proximal hamstring physical therapy protocols from US academic orthopaedic programs were reviewed. A web-based search using the search term complete proximal hamstring repair rehabilitation protocol provided an additional 14 protocols. A comprehensive scoring rubric was developed after review of all protocols and was used to assess each protocol for both the presence of various rehabilitation components and the point at which those components were introduced. Results: Of 50 rehabilitation protocols identified, 35 satisfied inclusion criteria and were analyzed. Twenty-five protocols (71%) recommended immediate postoperative bracing: 12 (34%) prescribed knee bracing, 8 (23%) prescribed hip bracing, and 5 (14%) did not specify the type of brace recommended. Fourteen protocols (40%) advised immediate nonweightbearing with crutches, while 16 protocols (46%) permitted immediate toe-touch weightbearing. Advancement to full weightbearing was allowed at a mean of 7.1 weeks (range, 4-12 weeks). Most protocols (80%) recommended gentle knee and hip passive range of motion and active range of motion, starting at a mean 1.4 weeks (range, 0-3 weeks) and 4.0 weeks (range, 0-6 weeks), respectively. However, only 6 protocols (17%) provided specific time points to initiate full hip and knee range of motion: a mean 8.0 weeks (range, 4-12 weeks) and 7.8 weeks (range, 0-12 weeks), respectively. Considerable variability was noted in the inclusion and timing of strengthening, stretching, proprioception, and cardiovascular exercises

  9. Variability of United States Online Rehabilitation Protocols for Proximal Hamstring Tendon Repair.

    Science.gov (United States)

    Lightsey, Harry M; Kantrowitz, David E; Swindell, Hasani W; Trofa, David P; Ahmad, Christopher S; Lynch, T Sean

    2018-02-01

    The optimal postoperative rehabilitation protocol following repair of complete proximal hamstring tendon ruptures is the subject of ongoing investigation, with a need for more standardized regimens and evidence-based modalities. To assess the variability across proximal hamstring tendon repair rehabilitation protocols published online by United States (US) orthopaedic teaching programs. Cross-sectional study. Online proximal hamstring physical therapy protocols from US academic orthopaedic programs were reviewed. A web-based search using the search term complete proximal hamstring repair rehabilitation protocol provided an additional 14 protocols. A comprehensive scoring rubric was developed after review of all protocols and was used to assess each protocol for both the presence of various rehabilitation components and the point at which those components were introduced. Of 50 rehabilitation protocols identified, 35 satisfied inclusion criteria and were analyzed. Twenty-five protocols (71%) recommended immediate postoperative bracing: 12 (34%) prescribed knee bracing, 8 (23%) prescribed hip bracing, and 5 (14%) did not specify the type of brace recommended. Fourteen protocols (40%) advised immediate nonweightbearing with crutches, while 16 protocols (46%) permitted immediate toe-touch weightbearing. Advancement to full weightbearing was allowed at a mean of 7.1 weeks (range, 4-12 weeks). Most protocols (80%) recommended gentle knee and hip passive range of motion and active range of motion, starting at a mean 1.4 weeks (range, 0-3 weeks) and 4.0 weeks (range, 0-6 weeks), respectively. However, only 6 protocols (17%) provided specific time points to initiate full hip and knee range of motion: a mean 8.0 weeks (range, 4-12 weeks) and 7.8 weeks (range, 0-12 weeks), respectively. Considerable variability was noted in the inclusion and timing of strengthening, stretching, proprioception, and cardiovascular exercises. Fifteen protocols (43%) required completion of

  10. Efficient Propulsion Structure with an Axial Flux Rotary Converter for HEV Drive Unit

    Directory of Open Access Journals (Sweden)

    Ales Havel

    2011-01-01

    Full Text Available This paper describes an efficient axial flux arrangement of the four quadrant rotary converter for hybrid electric vehicles. The design of the axial flux wound stator and both axial flux squirrel cage rotors is based on the arrangement of radial air gap induction motor and permanent magnet synchronous motor. The method of constant magnetic circuit volume is utilized for dimensions conversion, which results into basic dimensions of stator and rotor discs in axial flux conception. This allows the creation of real 3D models in the CAD application. Finally, the finite element simulations of electromagnetic induction in the axial flux stator pack are presented in the concluding part of this paper.

  11. A time to voltage converter and analog memory unit for straw tracking detectors

    International Nuclear Information System (INIS)

    Callewaert, L.; Eyckmans, W.; Sansen, W.; Stevens, A.; Van der Spiegel, J.; Van Berg, R.; Williams, H.H.; Yau, T.Y.

    1990-01-01

    In a high precision drift tube or straw tracking system, one measures the time of arrival of the first electron at the anode. While many possible schemes exist, the authors initial judgment was that an analog time measurement would offer both lower power and greater resolution than an equally complex digital system. In addition, they believe that it will be necessary to incorporate all of the system features such as connection to the trigger and DAQ systems in any usable design in order to keep the power, mass and complexity of the final system under control. A low power, sub-nanosecond accuracy, quick recovery, data-driven, multiple sample Time to Voltage Converter suitable for use on high rate straw tracking detectors is described. The described TVC includes virtual storage of analog data in both Level 1 and Level 2 queues and an on board ADC with first order correction for capacitance variations and non-linearities

  12. Protocol Additional to the Agreement between the United States of America and the International Atomic Energy Agency for the Application of Safeguards in the United States of America

    International Nuclear Information System (INIS)

    2009-01-01

    The text of the Protocol Additional to the Agreement between the United States of America and the International Atomic Energy Agency for the Application of Safeguards in the United States of America is reproduced in this document for the information of all Members. The Board of Governors approved the Additional Protocol on 11 June 1998. It was signed in Vienna on 12 June 1998

  13. Safety and efficacy of an intensive insulin protocol in a burn-trauma intensive care unit.

    Science.gov (United States)

    Cochran, Amalia; Davis, Lynn; Morris, Stephen E; Saffle, Jeffrey R

    2008-01-01

    Aggressive glycemic management in critically ill patients with acute burn injury or life-threatening soft-tissue infections has not been thoroughly evaluated. An intensive insulin protocol with target glucose values of less than 120 mg/dl was implemented in October 2005 in our regional Burn-Trauma intensive care unit. We reviewed our initial experience with this protocol to evaluate the safety and efficacy of aggressive glycemic control in these patient groups. Patients were placed on the intensive insulin protocol based upon the need for glycemic management during their hospitalization for burn or soft-tissue disease. Patient information prospectively collected while on protocol included all measured blood glucose values, total daily insulin use, and incidence of hypoglycemic episodes, defined as serum glucose patients (17 burns, 13 soft-tissue infections) were placed on the intensive insulin protocol during the first 16 months of use. The mean daily blood glucose level for burn patients was 115.9 mg/dl and for soft-tissue disease patients was 119.5 mg/dl. There was a 5% incidence of hypoglycemic episodes per protocol day. All hypoglycemic episodes were treated by holding the insulin infusion, and no episode had known adverse effects. Hyperglycemia in critically ill patients with burns and extensive soft-tissue disease can be effectively managed with an insulin protocol that targets blood glucose values of less than 120 mg/dl with minimal incidence of hypoglycemia. A multicenter prospective randomized trial would provide the ideal forum for evaluating clinical outcome benefits of using an intensive insulin protocol.

  14. High-efficiency and multi-frequency polarization converters based on graphene metasurface with twisting double L-shaped unit structure array

    Science.gov (United States)

    Chen, Ming; Xiao, Xiaofei; Chang, Linzi; Wang, Congyun; Zhao, Deping

    2017-07-01

    In this work, a high-efficiency and tunable dual-frequency reflective polarization converter composed of graphene metasurface with twisting double L-shaped unit is firstly realized. Numerical results demonstrate that the device can convert a linearly polarized wave to its cross-polarized wave, and meantime it can also convert to a circularly polarized wave. Subsequently, one thickness of 500 nm SiO2 layer sandwiched by two graphene metasurfaces with similar pattern is stacked on the top of the two-layered structure, a four-frequency efficient reflective polarization converters is realized. Above all, those working frequencies can also be dynamically tuned within a large frequency range by adjusting the Fermi energy of the graphene, without reoptimizing and refabricating the nanostructures, which paves a novel way toward developing a controllable polarization converter for mid-infrared applications.

  15. BIPAP protocol usage in patients admitted to the Internal Medicine unit

    Directory of Open Access Journals (Sweden)

    Óscar Bautista Villaécija

    2013-06-01

    Full Text Available The use of noninvasive mechanical ventilation equipment becomes more common in internal medicine units. Due to its indications, such as severe respiratory failure, or hypoxemic respiratory failure, it means a great help in these units. Within the multidisciplinary team, the medical staff is responsible for the prescription and programming of the device parameters, and the nursing staff handles such equipment and provides care to the patients requiring noninvasive mechanical ventilation.The objective of this protocol is to show in a clear and simple way, the noninvasive mechanical ventilation system, as well as its advantages and complications, and the nursing diagnoses that should be considered.

  16. Development and Pilot Implementation of a Search Protocol to Improve Patient Safety on a Psychiatric Inpatient Unit.

    Science.gov (United States)

    Abela-Dimech, Frances; Johnston, Kim; Strudwick, Gillian

    A mental health organization in Ontario, Canada, noted an increase in unsafe items entering locked inpatient units. The purpose of this project was to develop and implement a search protocol to improve patient, staff, and visitor safety by preventing unsafe items from entering a locked inpatient unit. Under the guidance of a clinical nurse specialist, an interprofessional team used the Failure Mode and Effects Analysis framework to identify what items were considered unsafe, how these unsafe items were entering the unit, and what strategies could be used to prevent these items from entering the unit. A standardized search protocol was identified as a strategy to prevent items from entering the unit. The standardized search protocol was developed and piloted on 1 unit. To support the search protocol, an interprofessional team created a poster using a mnemonic aid to educate patients, staff, and visitors about which items could not be brought onto the unit. Educational sessions on the search protocol were provided for staff. The difference between the number of incidents before and after the implementation of the search protocol was statistically significant. Safety on an inpatient unit was increased as incidents of unsafe items entering the unit decreased.

  17. The effects of a tailored intensive care unit delirium prevention protocol: A randomized controlled trial.

    Science.gov (United States)

    Moon, Kyoung-Ja; Lee, Sun-Mi

    2015-09-01

    A decreased incidence of delirium following the application of non-pharmacologic intervention protocols to several patient populations has been previously reported. However, few studies have been conducted to examine the effects of their application to intensive care unit (ICU) patients. To examine the effects of applying a tailored delirium preventive protocol, developed by the authors, to ICU patients by analyzing its effects on delirium incidence, in-hospital mortality, ICU readmission, and length of ICU stay in a Korean hospital. A single-blind randomized controlled trial. A 1049-bed general hospital with a 105-bed ICU. Sixty and 63 ICU patients were randomly assigned to the intervention and control groups, respectively. The researchers applied the delirium prevention protocol to the intervention group every day for the first 7 days of ICU hospitalization. Delirium incidence, mortality, and re-admission to the ICU during the same hospitalization period were analyzed by logistic regression analysis; the 7- and 30-day in-hospital mortality by Kaplan-Meier survival and Cox proportional hazard regression analysis; and length of ICU stay was assessed by linear regression analysis. Application of the protocol had no significant effect on delirium incidence, in-hospital mortality, re-admission to the ICU, or length of ICU stay. Whereas the risk of 30-day in-hospital mortality was not significantly lower in the intervention than in the control group (OR: 0.33; 95% CI: 0.10-1.09), we found a significantly decreased 7-day in-hospital mortality in the intervention group after protocol application (HR: 0.09; 95% CI: 0.01-0.72). Application of a tailored delirium prevention protocol to acute stage patients during the first 7 days of ICU hospitalization appeared to reduce the 7-day in-hospital risk of mortality only for this patient population. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Design and operating experience of an ac-dc power converter for a superconducting magnetic energy storage unit

    International Nuclear Information System (INIS)

    Boenig, H.J.; Nielsen, R.G.; Sueker, K.H.

    1984-01-01

    The design philosophy and the operating behavior of a 5.5 kA, +-2.5 kV converter, being the electrical interface between a high voltage transmission system and a 30 MJ superconducting coil, are documented in this paper. Converter short circuit tests, load tests under various control conditions, dc breaker tests for magnet current interruption, and converter failure modes are described

  19. Chronic idiopathic anal pain. Results of a diagnostic-therapeutic protocol in a colorectal referral unit.

    Science.gov (United States)

    Armañanzas, Laura; Arroyo, Antonio; Ruiz-Tovar, Jaime; López, Alberto; Santos, Jair; Moya, Pedro; Gómez, María Amparo; Candela, Fernando; Calpena, Rafael

    2015-01-01

    Chronic idiopathic anal pain (CIAP) remains a diagnosis of exclusion. Its study and management still lack a standardized protocol. The aim of this study is to evaluate the results obtained with the diagnostic-therapeutic protocol established in our service. We performed a retrospective study of patients diagnosed with CIAP at the Colorectal Unit of the General University Hospital of Elche, between 2005 and 2011. We evaluated 57 patients with a diagnosis of chronic anal pain for functional anorectal disease (FAD). After the application of our diagnostic protocol, final diagnosis of chronic anal pain (CAP) was achieved in 43 cases (75%), including 22 cases of descending perineum syndrome, 12 of proctalgia fugax, 2 of pudendal neuritis and 7 of coccydynia. In 14 patients exclusion diagnosis of CIAP was established. Among the therapies used on patients with CIAP, biofeedback combined with conservative measures improved symptoms in 43% of the cases. Sacral nerve stimulation was assessed in patients who did not respond to other treatments. Through proper anamnesis, physical examination and complementary tests, a specific diagnosis of the cause of CAP by FAD can be achieved, reducing exclusion diagnosis of CIAP to 25% of cases. Conservative measures combined with biofeedback achieved an improvement in pain in more than 40% of the cases of CIAP in our study. Sacral nerve stimulation can be considered as a treatment option in refractory cases. Copyright © 2013 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Comparative study of 2 oral care protocols in intensive care units.

    Science.gov (United States)

    Ory, Jérôme; Raybaud, Evelyne; Chabanne, Russell; Cosserant, Bernard; Faure, Jean Sébastien; Guérin, Renaud; Calvet, Laure; Pereira, Bruno; Mourgues, Charline; Guelon, Dominique; Traore, Ousmane

    2017-03-01

    The quality of oral care is important in limiting the emergence of ventilator-associated pneumonia (VAP) in intubated patients. Our main objective was to measure the quality improvement in oral care following the implementation of a new oral care protocol. We also monitored VAP rates. This was a cohort study of patients in 5 adult ICUs covering different specialties. During period 1, caregivers used a foam stick for oral care and during period 2 a stick and tooth brushing with aspiration. Oral chlorhexidine was used during both periods. The caregivers rated improvement in oral health on the basis of 4 criteria (tongue, mucous membranes, gingivae, and teeth). Caregiver satisfaction was also assessed. The incidence of VAP was monitored. A total of 2,030 intubated patients admitted to intensive care units benefited from oral care. The patient populations during the 2 periods were similar with regard to demographic data and VAP potential risk factors. Oral health was significantly better from the third day of oral care in period 2 onward (period 1, 6.4 ± 2.1; period 2, 5.6 ± 1.8; P = .043). Caregivers found the period 2 protocol easier to implement and more effective. VAP rates decreased significantly between the 2 periods (period 1, 12.8%; period 2, 8.5%; P = .002). Our study showed that the implementation of a simple strategy improved the quality of oral care of patients in intensive care units, and decreased VAP rates. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. Sustainability of protocolized handover of pediatric cardiac surgery patients to the intensive care unit.

    Science.gov (United States)

    Chenault, Kristin; Moga, Michael-Alice; Shin, Minah; Petersen, Emily; Backer, Carl; De Oliveira, Gildasio S; Suresh, Santhanam

    2016-05-01

    Transfer of patient care among clinicians (handovers) is a common source of medical errors. While the immediate efficacy of these initiatives is well documented, sustainability of practice changes that results in better processes of care is largely understudied. The objective of the current investigation was to evaluate the sustainability of a protocolized handover process in pediatric patients from the operating room after cardiac surgery to the intensive care unit. This was a prospective study with direct observation assessment of handover performance conducted in the cardiac ICU (CICU) of a free-standing, tertiary care children's hospital in the United States. Patient transitions from the operating room to the CICU, including the verbal handoff, were directly observed by a single independent observer in all phases of the study. A checklist of key elements identified errors classified as: (1) technical, (2) information omissions, and (3) realized errors. Total number of errors was compared across the different times of the study (preintervention, postintervention, and the current sustainability phase). A total of 119 handovers were studied: 41 preintervention, 38 postintervention, and 40 in the current sustainability phase. The median [Interquartile range (IQR)] number of technical errors was significantly reduced in the sustainability phase compared to the preintervention and postintervention phase, 2 (1-3), 6 (5-7), and 2.5 (2-4), respectively P = 0.0001. Similarly, the median (IQR) number of verbal information omissions was also significantly reduced in the sustainability phase compared to the preintervention and postintervention phases, 1 (1-1), 4 (3-5) and 2 (1-3), respectively. We demonstrate sustainability of an improved handover process using a checklist in children being transferred to the intensive care unit after cardiac surgery. Standardized handover processes can be a sustainable strategy to improve patient safety after pediatric cardiac surgery.

  2. Impact of a standardized nurse observation protocol including MEWS after Intensive Care Unit discharge.

    Science.gov (United States)

    De Meester, K; Das, T; Hellemans, K; Verbrugghe, W; Jorens, P G; Verpooten, G A; Van Bogaert, P

    2013-02-01

    Analysis of in-hospital mortality after serious adverse events (SAE's) in our hospital showed the need for more frequent observation in medical and surgical wards. We hypothesized that the incidence of SAE's could be decreased by introducing a standard nurse observation protocol. To investigate the effect of a standard nurse observation protocol implementing the Modified Early Warning Score (MEWS) and a color graphic observation chart. Pre- and post-intervention study by analysis of patients records for a 5-day period after Intensive Care Unit (ICU) discharge to 14 medical and surgical wards before (n=530) and after (n=509) the intervention. For the total study population the mean Patient Observation Frequency Per Nursing Shift (POFPNS) during the 5-day period after ICU discharge increased from .9993 (95% C.I. .9637-1.0350) in the pre-intervention period to 1.0732 (95% C.I. 1.0362-1.1101) (p=.005) in the post-intervention period. There was an increased risk of a SAE in patients with MEWS 4 or higher in the present nursing shift (HR 8.25; 95% C.I. 2.88-23.62) and the previous nursing shift (HR 12.83;95% C.I. 4.45-36.99). There was an absolute risk reduction for SAE's within 120h after ICU discharge of 2.2% (95% C.I. -0.4-4.67%) from 5.7% to 3.5%. The intervention had a positive impact on the observation frequency. MEWS had a predictive value for SAE's in patients after ICU discharge. The drop in SAE's was substantial but did not reach statistical significance. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Defining antimicrobial stewardship competencies for undergraduate health professional education in the United Kingdom: A study protocol.

    Science.gov (United States)

    Courtenay, Molly; Castro-Sánchez, Enrique; Deslandes, Rhian; Hodson, Karen; Lim, Rosemary; Morris, Gary; Reeves, Scott; Weiss, Marjorie

    2018-04-16

    Multi-drug resistant infections have been identified as one of the greatest threats to human health. Healthcare professionals are involved in an array of patient care activities for which an understanding of antimicrobial stewardship is important. Although antimicrobial prescribing and stewardship competencies have been developed for healthcare professionals who adopt the role of a prescriber, competencies do not exist for other medicine-related stewardship activities. Undergraduate education provides an ideal opportunity to prepare healthcare professionals for these roles and activities. This report presents a protocol for a study designed to provide national consensus on antimicrobial stewardship competencies appropriate for undergraduate healthcare professional education. A modified Delphi process will be used in which a panel of Experts, comprising members from across the United Kingdom, with expertise in prescribing and medicines management with regard to the education and practice of healthcare professionals, and antimicrobial prescribing and stewardship, will be invited to take part in two survey rounds. The competencies developed will be applicable to all undergraduate healthcare professional education programmes. They will help to standardise curricula content and enhance the impact of antimicrobial stewardship education.

  4. Importance of the use of protocols for the management of analgesia and sedation in pediatric intensive care unit

    Directory of Open Access Journals (Sweden)

    Emiliana Motta

    Full Text Available Summary Introduction: Analgesia and sedation are essential elements in patient care in the intensive care unit (ICU, in order to promote the control of pain, anxiety and agitation, prevent the loss of devices, accidental extubation, and improve the synchrony of the patient with mechanical ventilation. However, excess of these medications leads to rise in morbidity and mortality. The ideal management will depend on the adoption of clinical and pharmacological measures, guided by scales and protocols. Objective: Literature review on the main aspects of analgesia and sedation, abstinence syndrome, and delirium in the pediatric intensive care unit, in order to show the importance of the use of protocols on the management of critically ill patients. Method: Articles published in the past 16 years on PubMed, Lilacs, and the Cochrane Library, with the terms analgesia, sedation, abstinence syndrome, mild sedation, daily interruption, and intensive care unit. Results: Seventy-six articles considered relevant were selected to describe the importance of using a protocol of sedation and analgesia. They recommended mild sedation and the use of assessment scales, daily interruptions, and spontaneous breathing test. These measures shorten the time of mechanical ventilation, as well as length of hospital stay, and help to control abstinence and delirium, without increasing the risk of morbidity and morbidity. Conclusion: Despite the lack of controlled and randomized clinical trials in the pediatric setting, the use of protocols, optimizing mild sedation, leads to decreased morbidity.

  5. Converting serial networks to Ethernet communications

    Energy Technology Data Exchange (ETDEWEB)

    Rosado, Elroy [Freewave Technologies, Inc., Boulder, CO (United States). Latin America

    2008-07-01

    Many oil and gas producers and pipeline companies find themselves in an awkward position. They have invested millions of dollars in legacy serial communications systems and in most cases, millions more in older SCADA remote terminal units and electronic flow meters. There is a desire throughout most of the industry to convert these systems to Ethernet. This presentation will explore how Ethernet protocol offers advantages over the older serial communications in terms of peer to peer communication, faster polling cycles, and the ability to poll multiple devices at the same time. (author)

  6. Cost savings using a protocol approach to manage anemia in a hemodialysis unit.

    Science.gov (United States)

    Charlesworth, Emily C; Richardson, Robert M; Battistella, Marisa

    2014-01-01

    National guidelines recommend using anemia management protocols to guide treatment. The objective of this study was to determine if an anemia management protocol would improve hemoglobin (Hgb) indices in hemodialysis patients and to measure whether the protocol would reduce the use and cost of darbepoetin alfa (DBO) and intravenous (IV) iron in hemodialysis patients. An anemia management protocol was created and implemented for hemodialysis patients at our institution. A retrospective observational review of the use of DBO and IV iron as well as changes in Hgb, transferrin saturation and ferritin in 174 patients was conducted 6 months before and after implementation of the anemia protocol. The number of Hgb measurements in the target range increased from 44.3 to 46.0% (p = 0.48) after protocol implementation. The mean weekly dose of DBO was reduced from 34.56 ± 31.12 to 31.11 ± 28.64 μg post-protocol implementation (p = 0.011), which translated to a cost savings of USD 41,649 over 6 months. The mean monthly IV iron dose also decreased from 139.56 ± 98.83 to 97.65 ± 79.05 mg (p DBO and iron agents while increasing the number of patients in the target Hgb range, which led to significant cost savings in the treatment of anemia.

  7. Recall of intensive care unit stay in patients managed with a sedation protocol or a sedation protocol with daily sedative interruption: a pilot study.

    Science.gov (United States)

    Ethier, Cheryl; Burry, Lisa; Martinez-Motta, Carlos; Tirgari, Sam; Jiang, Depeng; McDonald, Ellen; Granton, John; Cook, Deborah; Mehta, Sangeeta

    2011-04-01

    Analgesics and sedatives are integral for the relief of pain and anxiety in critically ill patients. However, these agents may contribute to amnesia for intensive care unit (ICU) events; which has been associated with development of posttraumatic stress disorder. Drug administration strategies that minimize sedative use have been associated with less amnesia. The objective of this pilot study was to evaluate recall of ICU stay in patients managed with 2 sedation strategies: a sedation protocol or a combination of sedation protocol and daily sedative/analgesic interruption. A questionnaire was administered on day 3 following ICU discharge to evaluate patients' recollections of pain, anxiety, fear, and sleep, as well as memories for specific ICU procedures. Participants were ICU survivors who had been enrolled in SLEAP - a randomized pilot trial comparing two sedation strategies, at 3 university-affiliated medical/surgical ICUs. Twenty-one patients who regained orientation within 72 hours of ICU discharge completed the questionnaire. More than 50% of patients recalled experiencing pain, anxiety, and fear to a moderate or extreme extent; and 57% reported inadequate sleep while in the ICU. Of the 21 patients, 48%, 33%, and 29% had no memories of endotracheal tube suctioning, being on a "breathing machine," and being bathed, respectively. A notable percentage of patients discharged from the ICU report moderate to extreme pain, anxiety, and fear, and inability to sleep during their ICU stay; and 29% to 48% have no recall of specific ICU events. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. A CAMAC unit for charge measuring and pulse shape recording based on a fast, 8-bit parallel analog-to-digital converter

    International Nuclear Information System (INIS)

    Kulka, Z.; Kreciejewski, M.; Nadachowski, M.

    1990-08-01

    A device designed mainly for measuring systems for testing parameters of some type of detectors used in the high energy physics is described. The device is one-module CAMAC unit. It is equipped in a fast, 8-bit parallel analog-to-digital converter ''flash''type with a gated integrator at the input and a static RAM (4096 x 8 bit) at the output. The device enables measurements of the charge in pulses from detectors or registration of the shape of these pulses. The construction, operation and parameters of the circuits of the device are described and the way of programming functions using CAMAC dataway is given. 8 refs., 9 figs. (author)

  9. The Text of the Safeguards Transfer Agreement Relating to the Bilateral Agreement between Iran and the United States of America. Protocol of Suspension

    International Nuclear Information System (INIS)

    1974-01-01

    The text of the Protocol suspending the Safeguards Transfer Agreement of 4 March 1969 between the Agency, Iran and the United States of America is reproduced in this document for the information of all Members. The Protocol entered into force, pursuant to Section 3 thereof, on 15 May 1974.

  10. The Text of the Safeguards Transfer Agreement relating to the Bilateral Agreement between Colombia and the United States of America. Protocol Prolonging the Agreement

    International Nuclear Information System (INIS)

    1977-01-01

    The text of the Protocol of 28 March 1977 prolonging the Agreement of 9 December 1970 between the Agency, Colombia and the United States of America for the application of safeguards is reproduced in this document for the information of all Members. The Protocol entered into force, pursuant to section 2, on 28 March 1977.

  11. Hydrogen converters

    International Nuclear Information System (INIS)

    Mondino, Angel V.

    2003-01-01

    The National Atomic Energy Commission of Argentina developed a process of 99 Mo production from fission, based on irradiation of uranium aluminide targets with thermal neutrons in the RA-3 reactor of the Ezeiza Atomic Centre. These targets are afterwards dissolved in an alkaline solution, with the consequent liberation of hydrogen as the main gaseous residue. This work deals with the use of a first model of metallic converter and a later prototype of glass converter at laboratory scale, adjusted to the requirements and conditions of the specific redox process. Oxidized copper wires were used, which were reduced to elementary copper at 400 C degrees and then regenerated by oxidation with hot air. Details of the bed structure and the operation conditions are also provided. The equipment required for the assembling in cells is minimal and, taking into account the operation final temperature and the purge with nitrogen, the procedure is totally safe. Finally, the results are extrapolated for the design of a converter to be used in a hot cell. (author)

  12. The Text of a Protocol between the Agency and the Governments of Thailand and the United States of America Terminating the Agreement between the International Atomic Energy Agency, the Government of the Kingdom of Thailand and the Government of the United States of America for the Application of Safeguards and Terminating the Protocol Suspending that Agreement

    International Nuclear Information System (INIS)

    1976-01-01

    The text of a protocol between the Agency and the Governments of Thailand and the United States of America terminating the Agreement between the International Atomic Energy Agency, the Government of the Kingdom of Thailand and the Government of the United States of America for the Application of Safeguards and terminating the Protocol suspending that Agreement is reproduced in this document for the information of all Members. The Protocol entered into force on 27 June 1974, pursuant to Section 6 thereof.

  13. The Text of the Safeguards Transfer Agreement relating to the Bilateral Agreement between the Commonwealth of Australia and the United States of America. Protocol of Suspension

    International Nuclear Information System (INIS)

    1974-01-01

    The text of the protocol suspending the Safeguards Transfer Agreement of 26 September 1966 between the Agency, Australia and the United States of America is reproduced in this document for the information of all Members

  14. The Text of the Safeguards Transfer Agreement relating to the Bilateral Agreement between Sweden and the United States of America. Protocol of Suspension

    International Nuclear Information System (INIS)

    1975-01-01

    The text of the Protocol of 14 April 1975 suspending the Safeguards Transfer Agreement of 1 March 1972 between the Agency, Sweden and the United States of America is reproduced in this document for the information of all Members

  15. The Text of the Safeguards Transfer Agreement relating to the Bilateral Agreement between Thailand and the United States of America. Protocol of Suspension

    International Nuclear Information System (INIS)

    1976-01-01

    The text of the Protocol suspending the Safeguards Transfer Agreement of 30 September 1964 between the Agency, Thailand and the United States of America is reproduced in this document for the information of all Members

  16. Successful implementation of a packed red blood cell and fresh frozen plasma transfusion protocol in the surgical intensive care unit.

    Directory of Open Access Journals (Sweden)

    Benjamin E Szpila

    Full Text Available Blood product transfusions are associated with increased morbidity and mortality. The purpose of this study was to determine if implementation of a restrictive protocol for packed red blood cell (PRBC and fresh frozen plasma (FFP transfusion safely reduces blood product utilization and costs in a surgical intensive care unit (SICU.We performed a retrospective, historical control analysis comparing before (PRE and after (POST implementation of a restrictive PRBC/FFP transfusion protocol for SICU patients. Univariate analysis was utilized to compare patient demographics and blood product transfusion totals between the PRE and POST cohorts. Multivariate logistic regression models were developed to determine if implementation of the restrictive transfusion protocol is an independent predictor of adverse outcomes after controlling for age, illness severity, and total blood products received.829 total patients were included in the analysis (PRE, n=372; POST, n=457. Despite higher mean age (56 vs. 52 years, p=0.01 and APACHE II scores (12.5 vs. 11.2, p=0.006, mean units transfused per patient were lower for both packed red blood cells (0.7 vs. 1.2, p=0.03 and fresh frozen plasma (0.3 vs. 1.2, p=0.007 in the POST compared to the PRE cohort, respectively. There was no difference in inpatient mortality between the PRE and POST cohorts (7.5% vs. 9.2%, p=0.39. There was a decreased risk of urinary tract infections (OR 0.47, 95%CI 0.28-0.80 in the POST cohort after controlling for age, illness severity and amount of blood products transfused.Implementation of a restrictive transfusion protocol can effectively reduce blood product utilization in critically ill surgical patients with no increase in morbidity or mortality.

  17. Effect of Different Disinfection Protocols on Microbial and Biofilm Contamination of Dental Unit Waterlines in Community Dental Practices

    Directory of Open Access Journals (Sweden)

    Laura Dallolio

    2014-02-01

    Full Text Available Output water from dental unit waterlines (DUWLs may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02% and stabilized chlorine dioxide (0.22%, respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions.

  18. Effect of different disinfection protocols on microbial and biofilm contamination of dental unit waterlines in community dental practices.

    Science.gov (United States)

    Dallolio, Laura; Scuderi, Amalia; Rini, Maria S; Valente, Sabrina; Farruggia, Patrizia; Sabattini, Maria A Bucci; Pasquinelli, Gianandrea; Acacci, Anna; Roncarati, Greta; Leoni, Erica

    2014-02-18

    Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions.

  19. Data acquisition for a patient-directed intervention protocol in the dynamic intensive care unit setting.

    Science.gov (United States)

    Chlan, Linda; Patterson, Robert P; Heiderscheit, Annie

    2011-07-01

    Methods to easily, accurately, and efficiently obtain data in an ICU-based clinical trial can be challenging in this high-tech setting. Patient medical status and the dynamic nature of this clinical setting further complicate data collection. The purpose of this paper is to describe the modifications of commercially available headphones and the application of a data logging device to capture frequency and length of protocol use (music listening or headphones only for noise cancellation) without burdening participants or busy ICU nurses. With the automatic capture of protocol use by research participants, there have been no instances of lost data for this clinical trial. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Transfusion strategy in hematological intensive care unit: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Chantepie, Sylvain P; Mear, Jean-Baptiste; Guittet, Lydia; Dervaux, Benoît; Marolleau, Jean-Pierre; Jardin, Fabrice; Dutheil, Jean-Jacques; Parienti, Jean-Jacques; Vilque, Jean-Pierre; Reman, Oumedaly

    2015-11-23

    Packed red blood cell (PRBC) transfusion is required in hematology patients treated with chemotherapy for acute leukemia, autologous (auto) or allogeneic (allo) hematopoietic stem cell transplantation (HSCT). In certain situations like septic shock, hip surgery, coronary disease or gastrointestinal hemorrhage, a restrictive transfusion strategy is associated with a reduction of infection and death. A transfusion strategy using a single PRBC unit has been retrospectively investigated and showed a safe reduction of PRBC consumption and costs. We therefore designed a study to prospectively demonstrate that the transfusion of a single PRBC unit is safe and not inferior to standard care. The 1versus2 trial is a randomized trial which will determine if a single-unit transfusion policy is not inferior to a double-unit transfusion policy. The primary endpoint is the incidence of severe complication (grade ≥ 3) defined as stroke, transient ischemic attack, acute coronary syndrome, heart failure, elevated troponin level, intensive care unit transfer, death, new pulmonary infiltrates, and transfusion-related infections during hospital stays. The secondary endpoint is the number of PRBC units transfused per patient per hospital stay. Two hundred and thirty patients will be randomized to receive a single unit or double unit every time the hemoglobin level is less than 8 g/dL. All patients admitted for induction remission chemotherapy, auto-HSCT or allo-HSCT in hematology intensive care units will be eligible for inclusion. Sample size calculation has determined that a patient population of 230 will be required to prove that the 1-unit PRBC strategy is non-inferior to the 2-unit PRBC strategy. Hemoglobin threshold for transfusion is below 8 g/dL. Estimated percentage of complication-free hospital stays is 93 %. In a non-inferiority hypothesis, the number of patients to include is 230 with a power of 90 % and an alpha risk of 5 %. 14-128; Clinicaltrials.gov NCT02461264

  1. Long-Term Follow-Up of the Edmonton Protocol of Islet Transplantation in the United States.

    Science.gov (United States)

    Brennan, D C; Kopetskie, H A; Sayre, P H; Alejandro, R; Cagliero, E; Shapiro, A M J; Goldstein, J S; DesMarais, M R; Booher, S; Bianchine, P J

    2016-02-01

    We report the long-term follow-up of the efficacy and safety of islet transplantation in seven type 1 diabetic subjects from the United States enrolled in the multicenter international Edmonton Protocol who had persistent islet function after completion of the Edmonton Protocol. Subjects were followed up to 12 years with serial testing for sustained islet allograft function as measured by C-peptide. All seven subjects demonstrated continued islet function longer than a decade from the time of first islet transplantation. One subject remained insulin independent without the need for diabetic medications or supplemental transplants. One subject who was insulin-independent for over 8 years experienced graft failure 10.9 years after the first islet transplant. The remaining six subjects demonstrated continued islet function upon trial completion, although three had received a supplemental islet transplant each. At trial completion, five subjects were receiving insulin and two remained insulin independent, although one was treated with liraglutide. The median hemoglobin A1c was 6.3% (45 mmol/mol). All subjects experienced progressive decline in the C-peptide/glucose ratio. No patients experienced severe hypoglycemia, opportunistic infection, or lymphoma. Thus, although the rate and duration of insulin independence was low, the Edmonton Protocol was safe in the long term. Alternative approaches to islet transplantation are under investigation. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.

  2. Reemergence of Mycobacterium chimaera in Heater–Cooler Units despite Intensified Cleaning and Disinfection Protocol

    Science.gov (United States)

    Schreiber, Peter W.; Kuster, Stefan P.; Hasse, Barbara; Bayard, Cornelia; Rüegg, Christian; Kohler, Philipp; Keller, Peter M.; Bloemberg, Guido V.; Maisano, Francesco; Bettex, Dominique; Halbe, Maximilian; Sommerstein, Rami

    2016-01-01

    Invasive Mycobacterium chimaera infections after open-heart surgery have been reported internationally. These devastating infections result from aerosols generated by contaminated heater–cooler units used with extracorporeal circulation during surgery. Despite intensified cleaning and disinfection, surveillance samples from factory-new units acquired during 2014 grew nontuberculous mycobacteria after a median of 174 days. PMID:27649345

  3. Reemergence of Mycobacterium chimaera in Heater-Cooler Units despite Intensified Cleaning and Disinfection Protocol.

    Science.gov (United States)

    Schreiber, Peter W; Kuster, Stefan P; Hasse, Barbara; Bayard, Cornelia; Rüegg, Christian; Kohler, Philipp; Keller, Peter M; Bloemberg, Guido V; Maisano, Francesco; Bettex, Dominique; Halbe, Maximilian; Sommerstein, Rami; Sax, Hugo

    2016-10-01

    Invasive Mycobacterium chimaera infections after open-heart surgery have been reported internationally. These devastating infections result from aerosols generated by contaminated heater-cooler units used with extracorporeal circulation during surgery. Despite intensified cleaning and disinfection, surveillance samples from factory-new units acquired during 2014 grew nontuberculous mycobacteria after a median of 174 days.

  4. Ray converter

    International Nuclear Information System (INIS)

    Reiss, K.H.

    1976-01-01

    In a radiographic system a converter is used for changing image forming intensity distribution in a bundle of penetrating rays into a flow of electrically charged particles by electrodes located in a gas space and partly latticed (grids) which lie at potentials stepped from cathode to anode. The invention is particularly characterized by the provision of at least two grids extending between and parallel to the cathode and the anode. The electrical field which lies between two electrodes lies at least between the grids located closest to the cathode being to the extent of between 1 and 10 percent, in the average preferably 3 percent below the electrical break down field in the gas in a homogeneous electrical field

  5. Atomic energy: protocol between Canada and the United States of America

    International Nuclear Information System (INIS)

    1983-01-01

    This agreement amends an agreement signed June 15, 1955 between the governments of Canada and the United States of America concerning the exchange of nulcear technology, information, and materials between the two countries

  6. Two-year functional and anatomical results after converting treatment resistant eyes with exudative age-related macular degeneration to aflibercept in accordance with a treat and extend protocol.

    Science.gov (United States)

    Jørstad, Øystein Kalsnes; Faber, Rowan Thomas; Moe, Morten Carstens

    2017-08-01

    To study the effects of converting to aflibercept in accordance with a treat and extend (T&E) strategy in eyes with treatment resistant exudative age-related macular degeneration (AMD). Two-year prospective study of eyes with exudative AMD and persistent macular fluid despite monthly treatment with ranibizumab or bevacizumab. Eyes were converted to 2.0 mg aflibercept in accordance with a T&E protocol. Fifty eyes from 47 patients were included. At baseline, the mean central retinal thickness (CRT) was 273 μm and mean best-corrected visual acuity (BCVA) 0.25 logarithm of the minimal angle of resolution (logMAR). The mean number of aflibercept injections the first year was 9.2. After 1 year, there was a reduction in mean CRT to 228 μm (p < 0.001); 22 eyes (44%) had a dry macula; and the mean BCVA was 0.24 logMAR (p = 0.531). The mean number of aflibercept injections the second year was 8.0 (p = 0.013 compared to first year). After 2 years, 24 eyes (48%) received treatment more frequently than every eighth week. The mean CRT was 225 μm (p < 0.001 compared to baseline); 31 eyes (62%) had a dry macula; and mean BCVA was 0.32 logMAR (p = 0.005 compared to baseline). Five eyes did not complete 2 years of aflibercept treatment after failing to improve. A majority of eyes showed improved anatomic outcomes. There was a small decrease in mean BCVA after the second year of treatment. About half of the eyes required treatment more frequently than the recommended aflibercept label of an 8-week interval. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. A Standardized Shift Handover Protocol: Improving Nurses’ Safe Practice in Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Javad Malekzadeh

    2013-08-01

    Full Text Available Introduction: For maintaining the continuity of care and improving the quality of care, effective inter-shift information communication is necessary. Any handover error can endanger patient safety. Despite the importance of shift handover, there is no standard handover protocol in our healthcare settings. Methods In this one-group pretest-posttest quasi-experimental study conducted in spring and summer of 2011, we recruited a convenience sample of 56 ICU nurses. The Nurses’ Safe Practice Evaluation Checklist was used for data collection. The Content Validity Index and the inter-rater correlation coefficient of the checklist was 0.92 and 89, respectively. We employed the SPSS 11.5 software and the Mc Nemar and paired-samples t test for data analysis. Results: Study findings revealed that nurses’ mean score on the Safe Practice Evaluation Checklist increased significantly from 11.6 (2.7 to 17.0 (1.8 (P < 0.001. Conclusion: using a standard handover protocol for communicating patient’s needs and information improves nurses’ safe practice in the area of basic nursing care.

  8. Evaluation of American Board of Orthodontics certification protocols in postgraduate orthodontic programs in the United States and Canada.

    Science.gov (United States)

    Park, Jae Hyun; Putrus, Raphael R; Pruzansky, Dawn P; Grubb, John

    2017-03-01

    The objective of this study was to identify the board certification protocols that hospital and university-based postgraduate orthodontic programs have in place to prepare residents for the American Board of Orthodontics (ABO) certification examination. An electronic survey was sent to the program directors of each of the 72 postgraduate orthodontic programs in the United States and Canada. The survey consisted of 49 questions about demographics, resident case assignment protocols, and ABO examination preparation methods. The response rate was 81%. Most programs were 30 to 36 months in length (72.7%). Many residents had a case load of 51 to 75 during their first year (50.9%), with an average maximum case load of 70 to 109. There was a positive correlation with both the number of cases that first-year residents start and the length of the program (Spearman correlation coefficient = 0.379; P <0.01) when compared with maximum case load. Approximately 72% of the programs do not offer a written mock board examination; however, 72% reported offering a clinical mock board examination. ABO cases are identified within the first 6 months of most programs. About 88% of respondents believe that residents take advantage of the banking system, and that over the past 5 years ABO Initial Certification Examination applications have increased. Most program directors (89.1%) believe that their program length is sufficient for board preparation. Subjects tested in the written examination are integrated into the didactic curriculum and strengthened with ongoing literature reviews, with a passing rate over 90%. Clinical examination preparation varies, with most programs requiring a mock board examination for graduation. Total participation in both the Initial Certification Examination and banking has increased since 2010; better follow-up protocols are needed to track residents after graduation. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc

  9. The characteristics and prognosis of patients fulfilling the Appropriateness Evaluation Protocol in a medical admission unit; a prospective observational study

    DEFF Research Database (Denmark)

    Brabrand, Mikkel; Knudsen, Torben; Hallas, Jesper

    2011-01-01

    To examine the prognostic significance of fulfilling at least one of the Appropriateness Evaluation Protocol (AEP) criteria.......To examine the prognostic significance of fulfilling at least one of the Appropriateness Evaluation Protocol (AEP) criteria....

  10. The Text of the Safeguards Transfer Agreement relating to the Bilateral Agreement between Spain and the United States of America. Protocol of Suspension

    International Nuclear Information System (INIS)

    1994-02-01

    The text of the Protocol suspending the application of safeguards pursuant to the Safeguards Transfer Agreement of 9 December 1966, as amended, between the Agency, Spain and the United States of America is reproduced in this document for the information of all Members [es

  11. The NEIL Memory Research Unit: psychosocial, biological, physiological and lifestyle factors associated with healthy ageing: study protocol.

    Science.gov (United States)

    Hannigan, Caoimhe; Coen, Robert F; Lawlor, Brian A; Robertson, Ian H; Brennan, Sabina

    2015-01-01

    Population ageing is a global phenomenon that has characterised demographic trends during the 20th and 21st century. The rapid growth in the proportion of older adults in the population, and resultant increase in the incidence of age-related cognitive decline, dementia and Alzheimer's disease, brings significant social, economic and healthcare challenges. Decline in cognitive abilities represents the most profound threat to active and healthy ageing. Current evidence suggests that a significant proportion of cases of age-related cognitive decline and dementia may be preventable through the modification of risk factors including education, depressive symptomology, physical activity, social engagement and participation in cognitively stimulating activities. The NEIL Memory Research Unit cohort study was established to investigate factors related to brain health and the maintenance of cognitive function. A cohort of 1000 normally ageing adults aged 50 years and over are being recruited to participate in comprehensive assessments at baseline, and at follow-up once every 2 years. The assessment protocol comprises a comprehensive neuropsychological battery, some basic physical measures, psychosocial scales, questionnaire measures related to a range of health, lifestyle and behavioural factors, and a measure of resting state activity using electroencephalography (EEG). The NEIL Memory Research Unit cohort study will address key questions about brain health and cognitive ageing in the population aged 50+, with a particular emphasis on the influence of potentially modifiable factors on cognitive outcomes. Analyses will be conducted with a focus on factors involved in the maintenance of cognitive function among older adults, and therefore will have the potential to contribute significant knowledge related to key questions within the field of cognitive ageing, and to inform the development of public health interventions aimed at preventing cognitive decline and promoting

  12. Effectiveness of an early mobilization protocol in a trauma and burns intensive care unit: a retrospective cohort study.

    Science.gov (United States)

    Clark, Diane E; Lowman, John D; Griffin, Russell L; Matthews, Helen M; Reiff, Donald A

    2013-02-01

    Bed rest and immobility in patients on mechanical ventilation or in an intensive care unit (ICU) have detrimental effects. Studies in medical ICUs show that early mobilization is safe, does not increase costs, and can be associated with decreased ICU and hospital lengths of stay (LOS). The purpose of this study was to assess the effects of an early mobilization protocol on complication rates, ventilator days, and ICU and hospital LOS for patients admitted to a trauma and burn ICU (TBICU). This was a retrospective cohort study of an interdisciplinary quality-improvement program. Pre- and post-early mobility program patient data from the trauma registry for 2,176 patients admitted to the TBICU between May 2008 and April 2010 were compared. No adverse events were reported related to the early mobility program. After adjusting for age and injury severity, there was a decrease in airway, pulmonary, and vascular complications (including pneumonia and deep vein thrombosis) post-early mobility program. Ventilator days and TBICU and hospital lengths of stay were not significantly decreased. Using a historical control group, there was no way to account for other changes in patient care that may have occurred between the 2 periods that could have affected patient outcomes. The dose of physical activity both before and after the early mobility program were not specifically assessed. Early mobilization of patients in a TBICU was safe and effective. Medical, nursing, and physical therapy staff, as well as hospital administrators, have embraced the new culture of early mobilization in the ICU.

  13. Power converters for ITER

    CERN Document Server

    Benfatto, I

    2006-01-01

    The International Thermonuclear Experimental Reactor (ITER) is a thermonuclear fusion experiment designed to provide long deuterium– tritium burning plasma operation. After a short description of ITER objectives, the main design parameters and the construction schedule, the paper describes the electrical characteristics of the French 400 kV grid at Cadarache: the European site proposed for ITER. Moreover, the paper describes the main requirements and features of the power converters designed for the ITER coil and additional heating power supplies, characterized by a total installed power of about 1.8 GVA, modular design with basic units up to 90 MVA continuous duty, dc currents up to 68 kA, and voltages from 1 kV to 1 MV dc.

  14. Results after implementation of a protocol on the incidence of urinary tract infection in an intensive care unit.

    Science.gov (United States)

    Miranda, Anna Letícia; Oliveira, Ana Lúcia Lyrio de; Nacer, Daiana Terra; Aguiar, Cynthia Adalgisa Mesojedovas

    2016-09-09

    to compare the results of urinary tract infection incidence, by means of the rate of indwelling urethral catheter use, and to identify microorganisms in urine cultures and surveillance cultures before and after the implementation of a clinical protocol for intensive care unit patients . urinary tract infection is defined as a positive urine culture > 105 CFU/mL, notified by the hospital infection control service, six months before and after the implementation of the protocol. The sample consisted of 47 patients, 28 reported before and 19 after implementation. The protocol established in the institution is based on the Ministry of Health manual to prevent healthcare-related infections; the goal is patient safety and improving the quality of health services. a negative linear correlation was observed between the later months of implementation and the reduction of reported cases of urinary tract infection, using the Spearman rank order coefficient (p = 0.045), and a reduction in the number of urine culture microorganisms (p = 0.026) using the Fisher exact test. educational interventions with implementation protocols in health institutions favor the standardization of maintenance of the invasive devices, which may reduce colonization and subsequent infections. comparar os resultados da incidência de infecção do trato urinário, por meio da taxa de utilização do cateter vesical de demora e identificar os micro-organismos na urocultura e cultura de vigilância antes e após a implementação de um protocolo assistencial em pacientes internados em unidade de terapia intensiva. definiu-se infecção do trato urinário pacientes com urocultura positiva >105 UFC/mL, notificados pelo Serviço de Controle de Infecção Hospitalar, seis meses antes e após a implementação do protocolo. A amostra foi constituída por 47 pacientes, sendo 28 notificados antes e 19 após. O protocolo, criado na instituição, é baseado no manual do Ministério da Saúde na prevenção de

  15. Technologies for converter topologies

    Science.gov (United States)

    Zhou, Yan; Zhang, Haiyu

    2017-02-28

    In some embodiments of the disclosed inverter topologies, an inverter may include a full bridge LLC resonant converter, a first boost converter, and a second boost converter. In such embodiments, the first and second boost converters operate in an interleaved manner. In other disclosed embodiments, the inverter may include a half-bridge inverter circuit, a resonant circuit, a capacitor divider circuit, and a transformer.

  16. Wavelength converter technology

    DEFF Research Database (Denmark)

    Kloch, Allan; Hansen, Peter Bukhave; Poulsen, Henrik Nørskov

    1999-01-01

    Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers.......Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers....

  17. High-Performance Data Converters

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    -resolution internal D/A converters are required. Unit-element mismatch-shaping D/A converters are analyzed, and the concept of mismatch-shaping is generalized to include scaled-element D/A converters. Several types of scaled-element mismatch-shaping D/A converters are proposed. Simulations show that, when implemented...... in a standard CMOS technology, they can be designed to yield 100 dB performance at 10 times oversampling. The proposed scaled-element mismatch-shaping D/A converters are well suited for use as the feedback stage in oversampled delta-sigma quantizers. It is, however, not easy to make full use of their potential......-order difference of the output signal from the loop filter's first integrator stage. This technique avoids the need for accurate matching of analog and digital filters that characterizes the MASH topology, and it preserves the signal-band suppression of quantization errors. Simulations show that quantizers...

  18. Protocol challenges for on-the-job voice dosimetry of teachers in the United States and Finland

    NARCIS (Netherlands)

    Nix, John; Svec, Jan G.; Laukkanen, Anna-Maria; Titze, Ingo R.

    The occupational voice use of teachers has been an important research topic over the last 10 years. However, data collection on vocal loading in teachers at and away from the workplace poses significant challenges to the research protocol. The challenges include recruitment of subjects, voice data

  19. Process integration study of a kraft pulp mill converted to an ethanol production plant – Part A: Potential for heat integration of thermal separation units

    International Nuclear Information System (INIS)

    Fornell, Rickard; Berntsson, Thore

    2012-01-01

    Energy efficiency is an important parameter for the profitability of biochemical ethanol production from lignocellulosic raw material. The yield of ethanol is generally low due to the limited amount of fermentable compounds in the raw material. Increasing energy efficiency leads to possibilities of exporting more by-products, which in turn might reduce the net production cost of ethanol. Energy efficiency is also an important issue when discussing the repurposing of kraft pulp mills to biorefineries, since the mills in question most likely will be old and inefficient. Investing in energy efficiency measures might therefore have a large effect on the economic performance. This paper discusses energy efficiency issues related to the repurposing of a kraft pulp mill into a lignocellulosic ethanol production plant. The studied process is a typical Scandinavian kraft pulp mill that has been converted to a biorefinery with ethanol as main product. A process integration study, using pinch analysis and process simulations, has been performed in order to assess alternative measures for improving the energy efficiency. The improvements found have also been related to the possibilities for by-product sales from the plant (electricity and/or lignin). In a forthcoming paper, which is the second part of this process integration study, an economic analysis based on the results from this paper will be presented. - Highlights: ► Conversion of a kraft pulp mill to ethanol production. ► Heat integration of distillation/evaporation in a lignocellulosic ethanol plant. ► Advanced pinch curves used to find new integration possibilities. ► 35–40% reduction of steam demand.

  20. Text of a Protocol between the Agency and the Governments of Norway and the United States of America in Connection with the Application of Safeguards under a Co-Operation Agreement between the Two Governments

    International Nuclear Information System (INIS)

    1973-01-01

    The text of a protocol between the Agency and the Governments of Norway and the United States of America in connection with the application of safeguards under the Agreement for Co-operation between the Government of the United States of America and the Government of Norway Concerning Civil Uses of Atomic Energy signed on 4 May 1967, as amended, is reproduced herein for the information of all Members. The protocol entered into force on 25 September 1973 pursuant to Section 4.

  1. ITER convertible blanket evaluation

    International Nuclear Information System (INIS)

    Wong, C.P.C.; Cheng, E.

    1995-01-01

    Proposed International Thermonuclear Experimental Reactor (ITER) convertible blankets were reviewed. Key design difficulties were identified. A new particle filter concept is introduced and key performance parameters estimated. Results show that this particle filter concept can satisfy all of the convertible blanket design requirements except the generic issue of Be blanket lifetime. If the convertible blanket is an acceptable approach for ITER operation, this particle filter option should be a strong candidate

  2. Putting the Family Back in the Center: A Teach-Back Protocol to Improve Communication During Rounds in a Pediatric Intensive Care Unit.

    Science.gov (United States)

    Bogue, Terri L; Mohr, Lynn

    2017-06-01

    Patient- and family-centered care is endorsed by leading health care organizations. To incorporate the family in interdisciplinary rounds in the pediatric intensive care unit, it is necessary to prepare the family to be an integral member of the child's health care team. When the family is part of the health care team, interdisciplinary rounds ensure that the family understands the process of interdisciplinary rounds and that it is an integral part of the discussion. An evidence-based protocol to provide understanding and support to families related to interdisciplinary rounds has significant impact on satisfaction, trust, and patient outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Power converters definitions, classification and converter topologies

    CERN Document Server

    Bordry, Frederick

    2006-01-01

    This paper introduces power conversion principles and defines the terminology. The concepts of sources and switches are defined and classified. From the basic laws of source interconnections, a generic method of power converter synthesis is presented. Some examples illustrate this systematic method. Finally, the notions of commutation cell and soft commutation are introduced and discussed.

  4. Protocol additional to the agreement between the United Republic of Tanzania and the International Atomic Energy Agency for the application of safeguards in connection with the Treaty on the Non-Proliferation of Nuclear Weapons

    International Nuclear Information System (INIS)

    2005-01-01

    The text of the Protocol Additional to the Agreement between the United Republic of Tanzania and the International Atomic Energy Agency for the Application of Safeguards in Connection with the Treaty on the Non-Proliferation of Nuclear Weapons is reproduced in the Annex to this document for the information of all Members. The Board of Governors approved the Additional Protocol on 16 June 2004. It was signed on 23 September 2004 in Vienna. Pursuant to Article 17 of the Additional Protocol, the Protocol entered into force on 7 February 2005, the date on which the Agency received from the United Republic of Tanzania written notification that the United Republic of Tanzania's statutory and/or constitutional requirements for entry into force had been met

  5. Protocol Additional to the Agreement Between the United Arab Emirates and the International Atomic Energy Agency for the Application of Safeguards in Connection with the Treaty on the Non-Proliferation of Nuclear Weapons

    International Nuclear Information System (INIS)

    2011-01-01

    The text of the Protocol Additional to the Agreement between the United Arab Emirates and the International Atomic Energy Agency for the Application of Safeguards in Connection with the Treaty on the Non-Proliferation of Nuclear Weapons is reproduced in this document for the information of all Members. The Board of Governors approved the Additional Protocol on 3 March 2009. It was signed in Vienna on 8 April 2009. Pursuant to Article 17 of the Additional Protocol, the Protocol entered into force on 20 December 2010, the date on which the Agency received from the United Arab Emirates written notification that the United Arab Emirates' statutory and constitutional requirements for entry into force had been met [es

  6. Protocol additional to the agreement between the United Republic of Tanzania and the International Atomic Energy Agency for the application of safeguards in connection with the Treaty on the Non-Proliferation of Nuclear Weapons

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-03-07

    The text of the Protocol Additional to the Agreement between the United Republic of Tanzania and the International Atomic Energy Agency for the Application of Safeguards in Connection with the Treaty on the Non-Proliferation of Nuclear Weapons is reproduced in the Annex to this document for the information of all Members. The Board of Governors approved the Additional Protocol on 16 June 2004. It was signed on 23 September 2004 in Vienna. Pursuant to Article 17 of the Additional Protocol, the Protocol entered into force on 7 February 2005, the date on which the Agency received from the United Republic of Tanzania written notification that the United Republic of Tanzania's statutory and/or constitutional requirements for entry into force had been met.

  7. Protocol Additional to the Agreement Between the United Arab Emirates and the International Atomic Energy Agency for the Application of Safeguards in Connection with the Treaty on the Non-Proliferation of Nuclear Weapons

    International Nuclear Information System (INIS)

    2011-01-01

    The text of the Protocol Additional to the Agreement between the United Arab Emirates and the International Atomic Energy Agency for the Application of Safeguards in Connection with the Treaty on the Non-Proliferation of Nuclear Weapons is reproduced in this document for the information of all Members. The Board of Governors approved the Additional Protocol on 3 March 2009. It was signed in Vienna on 8 April 2009. Pursuant to Article 17 of the Additional Protocol, the Protocol entered into force on 20 December 2010, the date on which the Agency received from the United Arab Emirates written notification that the United Arab Emirates' statutory and constitutional requirements for entry into force had been met

  8. Parents' experiences of transition when their infants are discharged from the Neonatal Intensive Care Unit: a systematic review protocol.

    Science.gov (United States)

    Aagaard, Hanne; Uhrenfeldt, Lisbeth; Spliid, Mette; Fegran, Liv

    2015-10-01

    The objective of this review is to identify, appraise and synthesize the best available studies exploring parents' experiences of transition when their infants are discharged from the Neonatal Intensive Care Unit (NICU).The review questions are: Giving birth to a premature or sick infant is a stressful event for parents. The parents' presence and participation in the care of the infant is fundamental to reduce this stress and to provide optimal care for both the premature or sick infant and family. A full term pregnancy is estimated to last between 37 and 40 weeks. Preterm infants born before 28 week (5.1%) are defined as extremely preterm, while those who are born between 28 to 31 weeks (10.3%) are defined as very preterm. The majority of the preterm (84.1%) are born between 32 to 37 week and may have significant medical problems requiring prolonged hospitalization.The prevalence of preterm birth is increasing worldwide. More than one in ten babies are born preterm annually. This is equal to 15 million preterm infants born globally and the second largest direct cause of deaths in children below five. The highest rates of preterm birth are in Sub-Saharan Africa and South Asia (more than 60%) and the lowest rates are in Northern Africa, Western Asia, Latin America and the Caribbean. The preterm birth rates in the developing countries vary widely and follow a different pattern than in high income countries.The preterm birth rate has increased between 1990 and 2010 with an average of 0.8% annually in almost all countries. Morbidity among critically ill newborn and preterm infants vary widely from no late effects to severe complications, such as visual or hearing impairment, chronic lung disease, growth failure in infancy and specific learning impairments, dyslexia and reduced academic achievement. Full term infants may also experience significant health problems requiring neonatal intensive care. The most common reasons for a full term infant to be admitted to a NICU

  9. Cascaded resonant bridge converters

    Science.gov (United States)

    Stuart, Thomas A. (Inventor)

    1989-01-01

    A converter for converting a low voltage direct current power source to a higher voltage, high frequency alternating current output for use in an electrical system where it is desired to use low weight cables and other circuit elements. The converter has a first stage series resonant (Schwarz) converter which converts the direct current power source to an alternating current by means of switching elements that are operated by a variable frequency voltage regulator, a transformer to step up the voltage of the alternating current, and a rectifier bridge to convert the alternating current to a direct current first stage output. The converter further has a second stage series resonant (Schwarz) converter which is connected in series to the first stage converter to receive its direct current output and convert it to a second stage high frequency alternating current output by means of switching elements that are operated by a fixed frequency oscillator. The voltage of the second stage output is controlled at a relatively constant value by controlling the first stage output voltage, which is accomplished by controlling the frequency of the first stage variable frequency voltage controller in response to second stage voltage. Fault tolerance in the event of a load short circuit is provided by making the operation of the first stage variable frequency voltage controller responsive to first and second stage current limiting devices. The second stage output is connected to a rectifier bridge whose output is connected to the input of the second stage to provide good regulation of output voltage wave form at low system loads.

  10. Implementation of a mandatory checklist of protocols and objectives improves compliance with a wide range of evidence-based intensive care unit practices.

    Science.gov (United States)

    Byrnes, Matthew C; Schuerer, Douglas J E; Schallom, Marilyn E; Sona, Carrie S; Mazuski, John E; Taylor, Beth E; McKenzie, Wendi; Thomas, James M; Emerson, Jeffrey S; Nemeth, Jennifer L; Bailey, Ruth A; Boyle, Walter A; Buchman, Timothy G; Coopersmith, Craig M

    2009-10-01

    To determine a) if a checklist covering a diverse group of intensive care unit protocols and objectives would improve clinician consideration of these domains and b) if improved consideration would change practice patterns. Pre- and post observational study. A 24-bed surgical/burn/trauma intensive care unit in a teaching hospital. A total of 1399 patients admitted between June 2006 and May 2007. The first component of the study evaluated whether mandating verbal review of a checklist covering 14 intensive care unit best practices altered verbal consideration of these domains. Evaluation was performed using real-time bedside audits on morning rounds. The second component evaluated whether the checklist altered implementation of these domains by changing practice patterns. Evaluation was performed by analyzing data from the Project IMPACT database after patients left the intensive care unit. Verbal consideration of evaluable domains improved from 90.9% (530/583) to 99.7% (669/671, p < .0001) after verbal review of the checklist was mandated. Bedside consideration improved on the use of deep venous thrombosis prophylaxis (p < .05), stress ulcer prophylaxis (p < .01), oral care for ventilated patients (p < 0.01), electrolyte repletion (p < .01), initiation of physical therapy (p < .05), and documentation of restraint orders (p < .0001). Mandatory verbal review of the checklist resulted in a greater than two-fold increase in transferring patients out of the intensive care unit on telemetry (16% vs. 35%, p < .0001) and initiation of physical therapy (28% vs. 42%, p < .0001) compared with baseline practice. A mandatory verbal review of a checklist covering a wide range of objectives and goals at each patient's bedside is an effective method to improve both consideration and implementation of intensive care unit best practices. A bedside checklist is a simple, cost-effective method to prevent errors of omission in basic domains of intensive care unit management that might

  11. Amplitude-to-frequency converter of radioisotope instruments

    International Nuclear Information System (INIS)

    Demchenkov, V.P.; Korobkov, I.N.

    1988-01-01

    An amplitude-to-frequency converter designed for signal processing of radioisotope relay devices is descibed. The basic elements of the converter are a scaling amplifier, an analog-to-digital converter, a code-to-frequency converter, a null-organ, a delay unit and a clock-pulse generator. The designed amplitude-to-frequency converter takes into account a prior information about the signal shape of the energy spectrum. The converter processes input pulses of 0.10 V amplitude and duration more than 2μs. The energy channel number is 64

  12. Development and implementation of a clinical pathway for cardiac surgery in the intensive care unit: Effects on protocol adherence.

    Science.gov (United States)

    van der Kolk, Marion; van den Boogaard, Mark; Ter Brugge-Speelman, Corine; Hol, Jeroen; Noyez, Luc; van Laarhoven, Kees; van der Hoeven, Hans; Pickkers, Peter

    2017-12-01

    Cardiac surgery (CS) is facilitated by multiple perioperative guidelines and protocols. Use of a clinical pathway (CP) may facilitate the care of these patients. This is a pre-post design study in the ICU of a tertiary referral centre. A CP for CS patients in the ICU was developed by ICU-nurses and enabled them to execute proactively predefined actions in accordance with and within the preset boundaries which were part of a variance report. A tailored implementation strategy was used. Primary outcome measure was protocol adherence above 80% on the domains of blood pressure control, action on chest tube blood loss and electrolyte control within the CP. In a 4-month period, 84 consecutive CP patients were included and compared with 162 matched control patients admitted in the year before implementation; 3 patients were excluded. Propensity score was used as matching parameter. CP patients were more likely to receive early adequate treatment for derangements in electrolytes (96% vs 47%, P blueprint for the implementation and use of a CP in low-volume high complex surgery. © 2017 John Wiley & Sons, Ltd.

  13. SSG Wave Energy Converter

    DEFF Research Database (Denmark)

    Margheritini, Lucia; Vicinanza, Diego; Frigaard, Peter

    2008-01-01

    The SSG (Sea Slot-cone Generator) is a wave energy converter of the overtopping type. The structure consists of a number of reservoirs one on the top of each others above the mean water level, in which the water of incoming waves is stored temporary. In each reservoir, expressively designed low...... head hydroturbines are converting the potential energy of the stored water into power. A key to success for the SSG will be the low cost of the structure and its robustness. The construction of the pilot plant is scheduled and this paper aims to describe the concept of the SSG wave energy converter...

  14. Electric current - frequency converter

    International Nuclear Information System (INIS)

    Kumahara, Tadashi; Kinbana, Setsuro.

    1967-01-01

    Herein disclosed is an improved simple electric current-frequency converter, the input current and output frequency linearity of which is widened to a range of four to five figures while compensating, for temperature. The converter may be used for computor processing and for telemetering the output signals from a nuclear reactor. The converter is an astable multivibrator which includes charging circuits comprising emitter-voltage compensated NPN transistors, a charged voltage detecting circuit of temperature compensated field effect transistors, and a transistor switching circuit for generating switching pulses independent of temperature. The converter exhibited a 0.7% frequency change within a range of 5 - 45 0 C and less than a 0.1% frequency drift after six hours of operation when the input current was maintained constant. (Yamaguchi, T.)

  15. Improving Power Converter Reliability

    DEFF Research Database (Denmark)

    Ghimire, Pramod; de Vega, Angel Ruiz; Beczkowski, Szymon

    2014-01-01

    of a high-power IGBT module during converter operation, which may play a vital role in improving the reliability of the power converters. The measured voltage is used to estimate the module average junction temperature of the high and low-voltage side of a half-bridge IGBT separately in every fundamental......The real-time junction temperature monitoring of a high-power insulated-gate bipolar transistor (IGBT) module is important to increase the overall reliability of power converters for industrial applications. This article proposes a new method to measure the on-state collector?emitter voltage...... is measured in a wind power converter at a low fundamental frequency. To illustrate more, the test method as well as the performance of the measurement circuit are also presented. This measurement is also useful to indicate failure mechanisms such as bond wire lift-off and solder layer degradation...

  16. Outcome of patients with stage III or inoperable WT treated on the second United Kingdom WT protocol (UKWT2); a United Kingdom Children's Cancer Study Group (UKCCSG) study.

    Science.gov (United States)

    Grundy, R G; Hutton, C; Middleton, H; Imeson, J; Pritchard, J; Kelsey, A; Marsden, H B; Vujanic, G M; Taylor, R E

    2004-04-01

    The aims of UKWT2 included consolidating the results for stage III patients obtained in UKWT1 and improving the outcome for patients with inoperable tumours by giving vincristine, actinomycin-D and doxorubicin in an intensive schedule (Intensive AVA). The second UK WT trial (UKWT2) ran between July 1986 and September 1991 accruing 448 patients. One hundred and six patients were diagnosed and treated for stage III disease. Six had clear cell sarcoma of the kidney (CCSK) and seven had rhabdoid tumours of the kidney (RTK) and are analysed separately. One other patient was excluded from overall analysis. Ninety-two patients were followed for a median of 115 months. Seventy-five received standard chemotherapy and abdominal radiotherapy according to protocol. Seventeen had stage III disease at immediate nephrectomy, but radiotherapy was omitted by physician choice. Thirty-three patients had inoperable disease at diagnosis and received pre-nephrectomy chemotherapy. Overall survival (OS) at 4 years for stage III favourable histology (FH) patients receiving abdominal RT was 83% (CI: 73-89). For children with stage III disease in whom RT was omitted the OS was 82% (CI: 59-97) and for inoperable disease 94% (CI: 78-98). The overall and event-free survival (EFS) of children with stage III CCSK was 100% and was achieved with the majority of patients not receiving radiotherapy (CI: 48-100). Three of seven children with RTK are alive EFS and OS 43% (CI: 10-73). For patients treated by abdominal radiotherapy the overall local control rate was 94.4% (CI: 86.4-98.5*%), 96.7% (CI: 88.5-99.6%) for flank RT and 83.3% (51.6-98.0%) for whole abdominal radiotherapy (WRT). The outcome for stage III FH disease was similar to that reported for UKWT1 and NWTS-3. The combination of abdominal RT together with 3-drug chemotherapy achieves a high abdominal tumour control rate. Flank RT is probably sufficient for localised tumour rupture. The high cure rates for children in this trial with

  17. Thermionic photovoltaic energy converter

    Science.gov (United States)

    Chubb, D. L. (Inventor)

    1985-01-01

    A thermionic photovoltaic energy conversion device comprises a thermionic diode mounted within a hollow tubular photovoltaic converter. The thermionic diode maintains a cesium discharge for producing excited atoms that emit line radiation in the wavelength region of 850 nm to 890 nm. The photovoltaic converter is a silicon or gallium arsenide photovoltaic cell having bandgap energies in this same wavelength region for optimum cell efficiency.

  18. MASMA: a versatile multifunctional unit (gated window amplifier, analog memory, and height-to-time converter); Element multifonctionnel M.A.S.M.A. (module amplificateur a seuil, memoire analogique et convertisseur amplitude-temps)

    Energy Technology Data Exchange (ETDEWEB)

    Goursky, V.; Thenes, P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    This multipurpose unit is designed to accomplish one of the following functions: - gated window amplifier, - Analog memory and - Amplitude-to-time converter. The first function is mainly devoted to improve the poor resolution of pulse-height analyzers with a small number of channels. The analog memory, a new function in the standard range of plug-in modules, is capable of performing a number of operations: 1) fixed delay, or variable delay dependent on an external parameter (application to the analog processing of non-coincident pulses), 2) de-randomiser to increase the efficiency of the pulse height analysis in a spectrometry experiment, 3) linear multiplexer to allow an analyser to serve as many spectrometry devices as memory elements that it possesses. Associated with a coding scaler, this unit, if used as a amplitude-to-time converter, constitutes a Wilkinson A.D.C with a capability of 10 bits (or more) and with a 100 MHz clock frequency. (authors) [French] Le present element est concu pour etre utilise dans l'un des modes de fonctionnement suivants: - amplificateur a seuil avec porte, - memoire analogique, - convertisseur amplitude-temps. La fonction amplificateur a seuil est destinee principalement a remedier a la resolution insuffisante de certains analyseurs d'amplitude possedant un faible nombre de canaux. La fonction memoire analogique est une fonction qui n'existe pas encore dans la gamme d'elements standardises. Elle peut trouver de nombreuses applications; a titre d'exemple, citons: 1) element de retard fixe ou dependant d'un parametre externe (application au calcul analogique portant sur les impulsions), 2) memoire-tampon: placee devant un analyseur, elle augmente l'efficacite d'analyse d'une chaine de spectrometrie, 3) multiplexeur analogique, permettant a un seul analyseur de desservir autant de voies de spectrometrie qu'il possede de memoires. En fonction convertisseur amplitude-temps, ce tiroir

  19. Bed Utilisation in an Irish Regional Paediatric Unit A Cross-Sectional Study Using the Paediatric Appropriateness Evaluation Protocol (PAEP)

    LENUS (Irish Health Repository)

    Ó hAiseadha, Coilín

    2016-05-01

    Increasing demand for limited healthcare resources raises questions about appropriate use of inpatient beds. In the first paediatric bed utilisation study at a regional university centre in Ireland, we conducted a cross-sectional study to audit the utilisation of inpatient beds at the Regional Paediatric Unit (RPU) in University Hospital Limerick (UHL), Limerick, Ireland and also examined hospital activity data, to make recommendations for optimal use of inpatient resources.

  20. Pilot cluster randomised controlled trial of flooring to reduce injuries from falls in elderly care units: study protocol.

    Science.gov (United States)

    Drahota, Amy; Gal, Diane; Windsor, Julie; Dixon, Simon; Udell, Julie; Ward, Derek; Soilemezi, Dia; Dean, Taraneh; Severs, Martin

    2011-12-01

    Falls are an issue disproportionately affecting older people who are at increased risk of falls and injury. This protocol describes a pilot study investigating shock-absorbing flooring for fall-related injuries in wards for older people. To inform future research by evaluating fall-related injuries on the intervention and existing flooring, assessing the sustainability of the flooring in ward environments, estimating the cost-effectiveness of the floor and assessing how the floor affects patients and other users. This study uses mixed methods a pilot cluster randomised controlled trial, observation via mechanical testing and interviews. Eight participating wards (clusters) are randomised using a computer-generated list. No blinding is incorporated into the study. Each site has a baseline period of approximately 6 months. Then, four sites receive the intervention floor, while four continue using standard floors. Sites are then followed up for approximately 1 year. Any person admitted to a bed in the 'study area' of a participating ward can be entered into the trial. Orientated patients, visitors and any hospital staff who use the floor in a study area are eligible for inclusion in an interview. An 8.3 mm thick vinyl floor covering with polyvinyl chloride foam backing (Tarkett Omnisports EXCEL). The primary outcome is fall-related injuries. Severity of injuries, falls, cost-effectiveness, user views and mechanical performance (shock absorbency and slip resistance) are also being assessed.

  1. Continuing global significance of emissions of Montreal Protocol-restricted halocarbons in the United States and Canada

    Science.gov (United States)

    Hurst, D. F.; Lin, J. C.; Romashkin, P. A.; Daube, B. C.; Gerbig, C.; Matross, D. M.; Wofsy, S. C.; Hall, B. D.; Elkins, J. W.

    2006-08-01

    Contemporary emissions of six restricted, ozone-depleting halocarbons, chlorofluorocarbon-11 (CFC-11, CCl3F), CFC-12 (CCl2F2), CFC-113 (CCl2FCClF2), methyl chloroform (CH3CCl3), carbon tetrachloride (CCl4), and Halon-1211 (CBrClF2), and two nonregulated trace gases, chloroform (CHCl3) and sulfur hexafluoride (SF6), are estimated for the United States and Canada. The estimates derive from 900 to 2900 in situ measurements of each of these gases within and above the planetary boundary layer over the United States and Canada as part of the 2003 CO2 Budget and Regional Airborne-North America (COBRA-NA) study. Air masses polluted by anthropogenic sources, identified by concurrently elevated levels of carbon monoxide (CO), SF6, and CHCl3, were sampled over a wide geographical range of these two countries. For each polluted air mass, we calculated emission ratios of halocarbons to CO and employed the Stochastic Time-Inverted Lagrangian Transport (STILT) model to determine the footprint associated with the air mass. Gridded CO emission estimates were then mapped onto the footprints and combined with measured emission ratios to generate footprint-weighted halocarbon flux estimates. We present statistically significant linear relationships between halocarbon fluxes (excluding CCl4) and footprint-weighted population densities, with slopes representative of per capita emission rates. These rates indicate that contemporary emissions of five restricted halocarbons (excluding CCl4) in the United States and Canada continue to account for significant fractions (7-40%) of global emissions.

  2. SoC Design Approach Using Convertibility Verification

    Directory of Open Access Journals (Sweden)

    Basu Samik

    2008-01-01

    Full Text Available Abstract Compositional design of systems on chip from preverified components helps to achieve shorter design cycles and time to market. However, the design process is affected by the issue of protocol mismatches, where two components fail to communicate with each other due to protocol differences. Convertibility verification, which involves the automatic generation of a converter to facilitate communication between two mismatched components, is a collection of techniques to address protocol mismatches. We present an approach to convertibility verification using module checking. We use Kripke structures to represent protocols and the temporal logic to describe desired system behavior. A tableau-based converter generation algorithm is presented which is shown to be sound and complete. We have developed a prototype implementation of the proposed algorithm and have used it to verify that it can handle many classical protocol mismatch problems along with SoC problems. The initial idea for -based convertibility verification was presented at SLA++P '07 as presented in the work by Roopak Sinha et al. 2008.

  3. Conversion of a general quantum stabilizer code to an entanglement distillation protocol

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Ryutaroh [Department of Communications and Integrated Systems, Tokyo Institute of Technology, Tokyo 152-8552 (Japan)

    2003-07-25

    We show how to convert a quantum stabilizer code to a one- or two-way entanglement distillation protocol. The proposed conversion method is a generalization of those of Shor-Preskill and Nielsen-Chuang. The recurrence protocol and the quantum privacy amplification protocol are equivalent to the protocols converted from [[2, 1

  4. Conversion of a general quantum stabilizer code to an entanglement distillation protocol

    International Nuclear Information System (INIS)

    Matsumoto, Ryutaroh

    2003-01-01

    We show how to convert a quantum stabilizer code to a one- or two-way entanglement distillation protocol. The proposed conversion method is a generalization of those of Shor-Preskill and Nielsen-Chuang. The recurrence protocol and the quantum privacy amplification protocol are equivalent to the protocols converted from [[2, 1

  5. Protocol Additional to the agreement between the United Kingdom of Great Britain and Northern Ireland, the European Atomic Energy Community and the International Atomic Energy Agency for the application of safeguards in the United Kingdom of Great Britain and Northern Ireland in connection with the Treaty on the Non-Proliferation of Nuclear Weapons

    International Nuclear Information System (INIS)

    2005-01-01

    The text of the Protocol Additional to the Agreement between the United Kingdom of Great Britain and Northern Ireland, the European Atomic Energy Community and the International Atomic Energy Agency for the Application of Safeguards in the United Kingdom of Great Britain and Northern Ireland in Connection with the Treaty on the Non-Proliferation of Nuclear Weapons is reproduced in the Annex to this document for the information of all Members. The Additional Protocol was approved by the Board of Governors on 11 June 1998. It was signed in Vienna on 22 September 1998. Pursuant to Article 17 of the Additional Protocol, the Protocol entered into force on 30 April 2004, the date on which the Agency received written notification that the European Atomic Energy Community and the United Kingdom had met their respective internal requirements for entry into force

  6. Evaluation of an enhanced cleaning and disinfection protocol in Salmonella contaminated pig holdings in the United Kingdom.

    Directory of Open Access Journals (Sweden)

    Francesca Martelli

    Full Text Available Salmonella is the second most commonly reported zoonotic gastrointestinal pathogen in the European Union, and a significant proportion of the cases are linked to the consumption of contaminated pork. Reduction of Salmonella at the farm level helps to mininimise the contamination pressure at the slaughterhouse, and therefore the number of Salmonella bacteria entering the food chain. Cleaning and disinfection (C&D between batches of pigs is an intervention measure that has potential to reduce the transmission of Salmonella contamination within farms. In this study, two pig finisher buildings in each of 10 Salmonella positive farms were sampled pre-C&D, post-C&D, post-restocking with the following batch of pigs, and shortly before these pigs were sent to slaughter. The incoming batch of pigs was also sampled before it reached the study building (pre-restocking. At each visit, pooled and individual faecal samples were collected and Salmonella isolation was carried out according to an ISO 6579:2002 Annex D-based method. One building on each farm (intervention was cleaned and disinfected according to a rigorous protocol consisting of several steps and a Defra-approved disinfectant used at the General Orders concentration, whilst the other building (control was cleaned and disinfected as per normal farm routine. At the post-C&D visit, Enterobacteriaceae and total bacterial counts were determined to evaluate residual faecal contamination and general hygiene levels. Rodent specialists visited the farms before and after C&D and rodent carcasses were collected for Salmonella testing. The intervention buildings were significantly less likely (p = 0.004 to be positive for Salmonella after C&D. The pre-restocking pigs had the highest likelihood (p<0.001 of being Salmonella positive (often with multiple serovars and there was no significant difference between intervention and control buildings in Salmonella prevalence at the post-restocking visit (p = 0

  7. An Electromagnetic Beam Converter

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an electromagnetic beam converter and a method for conversion of an input beam of electromagnetic radiation having a bell shaped intensity profile a(x,y) into an output beam having a prescribed target intensity profile l(x',y') based on a further development...

  8. Converting the reset

    NARCIS (Netherlands)

    J.K. Hoogland (Jiri); C.D.D. Neumann; D. Bloch

    2001-01-01

    textabstractWe give a simple algorithm to incorporate the effects of resets in convertible bond prices, without having to add an extra factor to take into account the value of the reset. Furthermore we show that the effect of a notice period, and additional make-whole features, can be treated in a

  9. Definition of Power Converters

    CERN Document Server

    Bordry, F

    2015-01-01

    The paper is intended to introduce power conversion principles and to define common terms in the domain. The concept s of sources and switches are defined and classified. From the basic laws of source interconnections, a generic method of power converter synthesis is presented. Some examples illustrate this systematic method. Finally, the commutation cell and soft commuta tion are introduced and discussedd.

  10. Thermoelectrode for thermoelectric converter

    International Nuclear Information System (INIS)

    Bodiul, Pavel; Bondarciuc, Nicolae; Ghitu, Dumitru; Nikolaeva, Albina; Konopko, Leonid; Turcan, Ana

    2008-01-01

    The invention relates to the electronic engneering and can be used for manufacturing of thermoelectrodes for thermoelectric converters. The thermoelectrode is made of semiconductor anisotropic material in the form of thread in glass insulation. At the same timer, the thread is made of stannum-doped tellurium in the ratio of 0.1...3 at.%.

  11. The Convertible Arbitrage Strategy Analyzed

    NARCIS (Netherlands)

    Loncarski, I.; Ter Horst, J.R.; Veld, C.H.

    2006-01-01

    This paper analyzes convertible bond arbitrage on the Canadian market for the period 1998 to 2004.Convertible bond arbitrage is the combination of a long position in convertible bonds and a short position in the underlying stocks. Convertible arbitrage has been one of the most successful strategies

  12. Social determinants and maternal exposure to intimate partner violence of obstetric patients with severe maternal morbidity in the intensive care unit: a systematic review protocol.

    Science.gov (United States)

    Ayala Quintanilla, Beatriz Paulina; Taft, Angela; McDonald, Susan; Pollock, Wendy; Roque Henriquez, Joel Christian

    2016-11-28

    Maternal mortality is a potentially preventable public health issue. Maternal morbidity is increasingly of interest to aid the reduction of maternal mortality. Obstetric patients admitted to the intensive care unit (ICU) are an important part of the global burden of maternal morbidity. Social determinants influence health outcomes of pregnant women. Additionally, intimate partner violence has a great negative impact on women's health and pregnancy outcome. However, little is known about the contextual and social aspects of obstetric patients treated in the ICU. This study aimed to conduct a systematic review of the social determinants and exposure to intimate partner violence of obstetric patients admitted to an ICU. A systematic search will be conducted in MEDLINE, CINAHL, ProQuest, LILACS and SciELO from 2000 to 2016. Studies published in English and Spanish will be identified in relation to data reporting on social determinants of health and/or exposure to intimate partner violence of obstetric women, treated in the ICU during pregnancy, childbirth or within 42 days of the end of pregnancy. Two reviewers will independently screen for study eligibility and data extraction. Risk of bias and assessment of the quality of the included studies will be performed by using the Critical Appraisal Skills Programme (CASP) checklist. Data will be analysed and summarised using a narrative description of the available evidence across studies. This systematic review protocol will be reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Protocols (PRISMA-P) guidelines. Since this systematic review will be based on published studies, ethical approval is not required. Findings will be presented at La Trobe University, in Conferences and Congresses, and published in a peer-reviewed journal. CRD42016037492. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Implementing health promotion in schools: protocol for a realist systematic review of research and experience in the United Kingdom (UK

    Directory of Open Access Journals (Sweden)

    Pearson Mark

    2012-10-01

    Full Text Available Abstract Background School-based interventions and campaigns are used to promote health and address a wide variety of public health problems. Schools are considered to be key sites for the implementation of health promotion programmes for their potential to reach the whole population in particular age-groups and instil healthy patterns of behavior early in life. However, evidence for the effectiveness of school-based health promotion interventions is highly variable. Systematic reviews of the evidence of school-based interventions tend to be highly problem- or intervention- specific, thereby missing potential generic insights into implementation and effectiveness of such programmes across problems. Methods/design A realist systematic review will be undertaken to explain how, why and in what circumstances schools can provide feasible settings for effective health promotion programmes in the United Kingdom (UK. The review will be conducted in two phases. Phase 1 will identify programme theories about implementation (ideas about what enables or inhibits effective health promotion to be delivered in a school setting. Phase 2 will test the programme theories so that they can be challenged, endorsed and/or refined. A Review Advisory Group of education and health professionals will be convened to help identify and choose potential programme theories, provide a ‘reality check’ on the clarity and explanatory strength of the mechanisms to be tested, and help shape the presentation of findings to be usable by practitioners and decision-makers. Review findings will be disseminated through liaison with decision-makers, and voluntary and professional groups in the fields of education and health.

  14. Effectiveness of osteopathic manipulative treatment in neonatal intensive care units: protocol for a multicentre randomised clinical trial

    Science.gov (United States)

    Cerritelli, Francesco; Pizzolorusso, Gianfranco; Renzetti, Cinzia; D'Incecco, Carmine; Fusilli, Paola; Perri, Paolo Francesco; Tubaldi, Lucia; Barlafante, Gina

    2013-01-01

    Introduction Neonatal care has been considered as one of the first priorities for improving quality of life in children. In 2010, 10% of babies were born prematurely influencing national healthcare policies, economic action plans and political decisions. The use of complementary medicine has been applied to the care of newborns. One previous study documented the positive effect of osteopathic manipulative treatment (OMT) in reducing newborns’ length of stay (LOS). Aim of this multicentre randomised controlled trial is to examine the association between OMT and LOS across three neonatal intensive care units (NICUs). Methods and analysis 690 preterm infants will be recruited from three secondary and tertiary NICUs from north and central Italy and allocated into two groups, using permuted-block randomisation. The two groups will receive standard medical care and OMT will be applied, twice a week, to the experimental group only. Outcome assessors will be blinded of study design and group allocation. The primary outcome is the mean difference in days between discharge and entry. Secondary outcomes are difference in daily weight gain, number of episodes of vomit, regurgitation, stooling, use of enema, time to full enteral feeding and NICU costs. Statistical analyses will take into account the intention-to-treat method. Missing data will be handled using last observation carried forward (LOCF) imputation technique. Ethics and dissemination Written informed consent will be obtained from parents or legal guardians at study enrolment. The trial has been approved by the ethical committee of Macerata hospital (n°22/int./CEI/27239) and it is under review by the other regional ethics committees. Results Dissemination of results from this trial will be through scientific medical journals and conferences. Trial registration This trial has been registered at http://www.clinicaltrials.org (identifier NCT01645137). PMID:23430598

  15. Converter topologies and control

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Fernando; Qin, Hengsi; Chapman, Patrick

    2018-05-01

    An inverter includes a transformer that includes a first winding, a second winding, and a third winding, a DC-AC inverter electrically coupled to the first winding of the transformer, a cycloconverter electrically coupled to the second winding of the transformer, an active filter electrically coupled to the third winding of the transformer. The DC-AC inverter is adapted to convert the input DC waveform to an AC waveform delivered to the transformer at the first winding. The cycloconverter is adapted to convert an AC waveform received at the second winding of the transformer to the output AC waveform having a grid frequency of the AC grid. The active filter is adapted to sink and source power with one or more energy storage devices based on a mismatch in power between the DC source and the AC grid.

  16. Converting high boiling hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Terrisse, H; DuFour, L

    1929-02-12

    A process is given for converting high boiling hydrocarbons into low boiling hydrocarbons, characterized in that the high boiling hydrocarbons are heated to 200 to 500/sup 0/C in the presence of ferrous chloride and of such gases as hydrogen, water gas, and the like gases under a pressure of from 5 to 40 kilograms per square centimeter. The desulfurization of the hydrocarbons occurs simultaneously.

  17. Advanced converters and reactors

    International Nuclear Information System (INIS)

    Haefele, W.; Kessler, G.

    1984-01-01

    As Western Europe and most countries of the Asia-Pacific region (except Australia) have only small natural uranium resources, they must import nuclear fuel from the major uranium supplier countries. The introduction of advanced converter and breeder reactor technology allows a fuel utilization of a factor of 4 to 100 higher than with present low converters (LWRs) and will make uranium-importing countries less vulnerable to price jumps and supply stops in the uranium market. In addition, breeder-reactor technology will open up a potential that can cover world energy requirements for several thousand years. The enormous development costs of advanced converter and breeder technologies can probably be raised only by highly industrialized countries. Those highly industrialized countries that have little or no uranium resources (Western Europe, Japan) will probably be the first to introduce this advanced reactor technology on a commercial scale. A number of small countries and islands will need only small power reactors with inherent safety capabilities, especially in the beginning of their nuclear energy programs. For economic reasons, the fuel cycle services should come from large reprocessing centers of countries having sufficiently large nuclear power programs or from international fuel cycle centers. (author)

  18. Power Converters Maximize Outputs Of Solar Cell Strings

    Science.gov (United States)

    Frederick, Martin E.; Jermakian, Joel B.

    1993-01-01

    Microprocessor-controlled dc-to-dc power converters devised to maximize power transferred from solar photovoltaic strings to storage batteries and other electrical loads. Converters help in utilizing large solar photovoltaic arrays most effectively with respect to cost, size, and weight. Main points of invention are: single controller used to control and optimize any number of "dumb" tracker units and strings independently; power maximized out of converters; and controller in system is microprocessor.

  19. Convertible bond valuation focusing on Chinese convertible bond market

    OpenAIRE

    Yang, Ke

    2010-01-01

    This paper mainly discusses the methods of valuation of convertible bonds in Chinese market. Different from common convertible bonds in European market, considering the complicate features of Chinese convertible bond, this paper represents specific pricing approaches for pricing convertible bonds with different provisions along with the increment of complexity of these provisions. More specifically, this paper represents the decomposing method and binomial tree method for pricing both of Non-...

  20. Bioremediation protocols

    National Research Council Canada - National Science Library

    Sheehan, David

    1997-01-01

    ..., .. . . . . .. ,. . . .. . . . . . . . .. . . . . .. . . .. . .. 3 2 Granular Nina Sludge Christiansen, Consortia lndra for Bioremediation, M. Mathrani, and Birgitte K. Ahring . 23 PART II PROTOCOLS...

  1. X-Y Converter Family

    DEFF Research Database (Denmark)

    Bhaskar, Mahajan Sagar; Sanjeevikumar, Padmanaban; Wheeler, Patrick

    2016-01-01

    A New breed of a buck boost converter, named as the XY converter family is proposed in this article. In the XY family, 16 topologies are presented which are highly suitable for renewable energy applications which require a high ratio of DC-DC converter; such as a photovoltaic multilevel inverter...... system, high voltage automotive applications and industrial drives. Compared to the traditional boost converter and existing recent converters, the proposed XY converter family has the ability to provide a higher output voltage by using less number of power devices and reactive components. Other distinct...... features of the XY converter family are i) Single control switch ii) Provide negative output voltage iii) Non-isolated topologies iv) High conversion ratio without making the use of high duty cycle and v) modular structure. XY family is compared with the recent high step-up converters and the detailed...

  2. Resonant power converters

    CERN Document Server

    Kazimierczuk, Marian K

    2012-01-01

    This book is devoted to resonant energy conversion in power electronics. It is a practical, systematic guide to the analysis and design of various dc-dc resonant inverters, high-frequency rectifiers, and dc-dc resonant converters that are building blocks of many of today's high-frequency energy processors. Designed to function as both a superior senior-to-graduate level textbook for electrical engineering courses and a valuable professional reference for practicing engineers, it provides students and engineers with a solid grasp of existing high-frequency technology, while acquainting them wit

  3. Cycloidal Wave Energy Converter

    Energy Technology Data Exchange (ETDEWEB)

    Stefan G. Siegel, Ph.D.

    2012-11-30

    This program allowed further advancing the development of a novel type of wave energy converter, a Cycloidal Wave Energy Converter or CycWEC. A CycWEC consists of one or more hydrofoils rotating around a central shaft, and operates fully submerged beneath the water surface. It operates under feedback control sensing the incoming waves, and converts wave power to shaft power directly without any intermediate power take off system. Previous research consisting of numerical simulations and two dimensional small 1:300 scale wave flume experiments had indicated wave cancellation efficiencies beyond 95%. The present work was centered on construction and testing of a 1:10 scale model and conducting two testing campaigns in a three dimensional wave basin. These experiments allowed for the first time for direct measurement of electrical power generated as well as the interaction of the CycWEC in a three dimensional environment. The Atargis team successfully conducted two testing campaigns at the Texas A&M Offshore Technology Research Center and was able to demonstrate electricity generation. In addition, three dimensional wave diffraction results show the ability to achieve wave focusing, thus increasing the amount of wave power that can be extracted beyond what was expected from earlier two dimensional investigations. Numerical results showed wave cancellation efficiencies for irregular waves to be on par with results for regular waves over a wide range of wave lengths. Using the results from previous simulations and experiments a full scale prototype was designed and its performance in a North Atlantic wave climate of average 30kW/m of wave crest was estimated. A full scale WEC with a blade span of 150m will deliver a design power of 5MW at an estimated levelized cost of energy (LCOE) in the range of 10-17 US cents per kWh. Based on the new results achieved in the 1:10 scale experiments these estimates appear conservative and the likely performance at full scale will

  4. Bed Utilisation in an Irish Regional Paediatric Unit – A Cross-Sectional Study Using the Paediatric Appropriateness Evaluation Protocol (PAEP

    Directory of Open Access Journals (Sweden)

    Coilín ÓhAiseadha

    2016-11-01

    Full Text Available Background Increasing demand for limited healthcare resources raises questions about appropriate use of inpatient beds. In the first paediatric bed utilisation study at a regional university centre in Ireland, we conducted a cross-sectional study to audit the utilisation of inpatient beds at the Regional Paediatric Unit (RPU in University Hospital Limerick (UHL, Limerick, Ireland and also examined hospital activity data, to make recommendations for optimal use of inpatient resources. Methods We used a questionnaire based on the paediatric appropriateness evaluation protocol (PAEP, modified and validated for use in the United Kingdom, to prospectively gather data regarding reasons for admission and for ongoing care after 2 days, from case records for all inpatients during 11 days in February (winter and 7 days in May–June (summer. We conducted bivariate and multivariate analysis to explore associations between failure to meet PAEP criteria and patient attributes including age, gender, admission outside of office hours, arrival by ambulance, and private health insurance. Inpatient bed occupancy and day ward activity were also scrutinised. Results Mean bed occupancy was 84.1%. In all, 12/355 (3.4%, 95% CI: 1.5%–5.3% of children failed to meet PAEP admission criteria, and 27/189 (14.3%, 95% CI: 9.3%–19.3% who were still inpatients after 2 days failed to meet criteria for ongoing care. 35/355 (9.9%, 95% CI: 6.8%–13.0% of admissions fulfilled only the PAEP criterion for intravenous medications or fluid replacement. A logistic regression model constructed by forward selection identified a significant association between failure to meet PAEP criteria for ongoing care 2 days after admission and admission during office hours (08.00–17.59 (P = .020, and a marginally significant association between this outcome and arrival by ambulance (P = .054. Conclusion At a mean bed occupancy of 84.1%, an Irish RPU can achieve 96.6% appropriate admissions

  5. A New Modular Multilevel Converter with Integrated Energy Storage

    DEFF Research Database (Denmark)

    Trintis, Ionut; Munk-Nielsen, Stig; Teodorescu, Remus

    2011-01-01

    applications. Furthermore, this solution can interconnect a DC and AC grid with bidirectional power flow, where both of them can receive or generate excess power to the third source integrated in each converter sub-module. This particularity enables the converter usage as a high voltage UPS system......This paper introduces a new modular converter with integrated energy storage based on the cascaded half-bridge modular multilevel converter with common DC bus. It represents a complete modular solution with power electronics and energy storage building blocks, for medium and high voltage...... in the future HVDC meshed grids. Its functionality and flexibility makes the converter independent on the energy storage unit characteristic. The converter concept with its basic functions and control schemes are described and evaluated in this paper....

  6. Gas converter. Gaswandler

    Energy Technology Data Exchange (ETDEWEB)

    Eisenmann, A

    1984-09-27

    A gas converter is proposed for carbonisation gas containing hydrocarbons, consisting of a bricked shaft, which has a free combustion chamber and a solid bed of bulk grainy material with partly burnt hot carbonisation gases flowing through it as the lower boundary of this combustion chamber, in the upper part of which a hot reaction zone at about 1000 to 1200/sup 0/C is formed and which has a cracked gas extraction below the solid bed and an ash outlet. The solid bed is arranged at an angle to the vertical. The shaft has a solid material outlet for the bed material no longer capable of taking part in the reaction on the wall going obliquely downwards and a solid material inlet for new bulk bed material on the opposite wall going obliquely upwards.

  7. Electromagnetic wave energy converter

    Science.gov (United States)

    Bailey, R. L. (Inventor)

    1973-01-01

    Electromagnetic wave energy is converted into electric power with an array of mutually insulated electromagnetic wave absorber elements each responsive to an electric field component of the wave as it impinges thereon. Each element includes a portion tapered in the direction of wave propagation to provide a relatively wideband response spectrum. Each element includes an output for deriving a voltage replica of the electric field variations intercepted by it. Adjacent elements are positioned relative to each other so that an electric field subsists between adjacent elements in response to the impinging wave. The electric field results in a voltage difference between adjacent elements that is fed to a rectifier to derive dc output power.

  8. Integrated power electronic converters and digital control

    CERN Document Server

    Emadi, Ali; Nie, Zhong

    2009-01-01

    Non-isolated DC-DC ConvertersBuck ConverterBoost ConverterBuck-Boost ConverterIsolated DC-DC ConvertersFlyback ConverterForward ConverterPush-Pull ConverterFull-Bridge ConverterHalf-Bridge ConverterPower Factor CorrectionConcept of PFCGeneral Classification of PFC CircuitsHigh Switching Frequency Topologies for PFCApplication of PFC in Advanced Motor DrivesIntegrated Switched-Mode Power ConvertersSwitched-Mode Power SuppliesThe Concept of Integrated ConverterDefinition of Integrated Switched-Mode Power Supplies (ISMPS)Boost-Type Integrated TopologiesGeneral Structure of Boost-Type Integrated T

  9. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable...... and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key...... features: Comprehensive analysis of the impedance source converter/inverter topologies, including typical topologies and derived topologies. Fully explains the design and control techniques of impedance source converters/inverters, including hardware design and control parameter design for corresponding...

  10. Impedance source power electronic converters

    CERN Document Server

    Liu, Yushan; Ge, Baoming; Blaabjerg, Frede; Ellabban, Omar; Loh, Poh Chiang

    2016-01-01

    Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key features: Comprehensive analysis of the impedance source converter/inverter topologies, including typical topologies and derived topologies. Fully explains the design and control techniques of impedance source converters/inverters, including hardware design and control parameter design for corresponding control methods. Presents the latest power conversion solutions that aim to advance the role of pow...

  11. Implementation of integration strategies between primary care units and a regional general hospital in Brazil to update and connect health care professionals: a quasi-experimental study protocol.

    Science.gov (United States)

    Bracco, Mario Maia; Mafra, Ana Carolina Cintra Nunes; Abdo, Alexandre Hannud; Colugnati, Fernando Antonio Basile; Dalla, Marcello Dala Bernardina; Demarzo, Marcelo Marcos Piva; Abrahamsohn, Ises; Rodrigues, Aline Pacífico; Delgado, Ana Violeta Ferreira de Almeida; Dos Prazeres, Glauber Alves; Teixeira, José Carlos; Possa, Silvio

    2016-08-12

    Better communication among field health care teams and points of care, together with investments focused on improving teamwork, individual management, and clinical skills, are strategies for achieving better outcomes in patient-oriented care. This research aims to implement and evaluate interventions focused on improving communication and knowledge among health teams based on points of care in a regional public health outreach network, assessing the following hypotheses: 1) A better-working communication process between hospitals and primary health care providers can improve the sharing of information on patients as well as patients' outcomes. 2) A skill-upgrading education tool offered to health providers at their work sites can improve patients' care and outcomes. A quasi-experimental study protocol with a mixed-methods approach (quantitative and qualitative) was developed to evaluate communication tools for health care professionals based in primary care units and in a general hospital in the southern region of São Paulo City, Brazil. The usefulness and implementation processes of the integration strategies will be evaluated, considering: 1) An Internet-based communication platform that facilitates continuity and integrality of care to patients, and 2) A tailored updating distance-learning course on ambulatory care sensitive conditions for clinical skills improvements. The observational study will evaluate a non-randomized cohort of adult patients, with historical controls. Hospitalized patients diagnosed with an ambulatory care sensitive condition will be selected and followed for 1 year after hospital discharge. Data will be collected using validated questionnaires and from patients' medical records. Health care professionals will be evaluated related to their use of education and communication tools and their demographic and psychological profiles. The primary outcome measured will be the patients' 30-day hospital readmission rates. A sample size of 560

  12. Electrostatic direct energy converter performance and cost scaling laws

    International Nuclear Information System (INIS)

    Hoffman, M.A.

    1977-08-01

    This study is concerned with electrostatic type direct energy converters for direct recovery of a large fraction of the plasma ion energy from fusion reactors. Simplified equations are presented for each of the important loss mechanisms in both single-stage direct converters and multistage ''Venetian Blind'' type direct converters. These equations can be used to estimate the efficiency and electric power output of the direct converter subsystem. Scaling relations for the cost of each major component in the direct converter subsystem are also given; these include the vacuum tank, direct converter modules, the DC power conditioning equipment, cryogenic vacuum pumping system and the thermal bottoming plant. The performance and cost scaling laws have been developed primarily for use in overall fusion power plant systems codes. However, to illustrate their utility, cost-effectiveness studies of two specific reference direct converter designs are presented in terms of the specific capital costs (i.e., the capital cost per unit electric power produced) for the Direct Converter Subsystem alone. Some examples of design improvements which can significantly reduce the specific capital costs of the Direct Converter Subsystem are also given

  13. Proposed electromagnetic wave energy converter

    Science.gov (United States)

    Bailey, R. L.

    1973-01-01

    Device converts wave energy into electric power through array of insulated absorber elements responsive to field of impinging electromagnetic radiation. Device could also serve as solar energy converter that is potentially less expensive and fragile than solar cells, yet substantially more efficient.

  14. Catalytic converters in the fireplace

    International Nuclear Information System (INIS)

    Kouki, J.

    1995-01-01

    In addition to selecting the appropriate means of heating and using dry fuel, the amount of harmful emissions contained by flue gases produced by fireplaces can be reduced by technical means. One such option is to use an oxidising catalytic converter. Tests at TTS Institute's Heating Studies Experimental Station have focused on two such converters (dense and coarse) mounted in light-weight iron heating stoves. The ability of the dense catalytic converter to oxidise carbon monoxide gases proved to be good. The concentration of carbon monoxide in the flue gases was reduced by as much as 90 %. Measurements conducted by VTT (Technical Research Centre of Finland) showed that the conversion of other gases, e.g. of methane, was good. The exhaust resistance caused by the dense converter was so great as to necessitate the mounting of a fluegas evacuation fan in the chimney for the purpose of creating sufficient draught. When relying on natural draught, the dense converter requires a chimney of at least 7 metres and a by-pass connection while the fire is being lit. In addition, the converter will have to be constructed to be less dense and this will mean that it's capability to oxidise non-combusted gases will be reduced. The coarse converter did not impair the draught but it's oxidising property was insufficient. With the tests over, the converter was not observed to have become blocked up by impurities

  15. Multilevel push pull power converter

    DEFF Research Database (Denmark)

    2007-01-01

    A power converter for converting an input voltage (Vin) into an output voltage (Vout), comprising a first supply potential and a second supply potential established by the input voltage, and at least one primary winding having two terminals, a center tap arranged between the two terminals and con...

  16. Parties at the convention of the United Nations on climatic change and second meeting of the parties to the Kyoto protocol

    International Nuclear Information System (INIS)

    2006-01-01

    Kenya hosted the second meeting of the Parties to the Kyoto Protocol in conjunction with the twelfth session of the conference of the Parties to the climatic change convention, in Nairobi from 6 to 17 November 2006. This document presents in a first part the key areas discussed at Nairobi; in a second part the international framework with the consequences of the Kyoto protocol implementation; and in the last part the demonstrable progresses of the France in the policy effects, tendencies concerning the greenhouse gases and the respect of the commitments. (A.L.B.)

  17. An Innovative Reconfigurable Integrated Converter Topology Suitable for Distributed Generation

    Directory of Open Access Journals (Sweden)

    Renato Rizzo

    2012-09-01

    Full Text Available The electricity market and environmental concerns, with wide utilization of renewable sources, have improved the diffusion of distributed generation units changing the operations of distribution grids from passive networks to microgrids. A microgrid includes a cluster of electrical loads, energy storage devices and microsources, which provide both power and heat to their local area. A microgrid has usually one connection point to the utility grid through power electronic converters placed at customers’ sites. This paper analyses a Reconfigurable Integrated Converter (RIC used for a domestic microgrid with inputs from the AC mains and photovoltaic arrays, and two DC outputs at different voltage levels. A RIC as a dual-boost DC-DC converter is proposed, modelled and analysed in the paper. The advantages of such a topology in comparison with traditional boost converters are outlined. Reported simulations results give evidence on the controllability of this converter and the capability of achieving the desired voltage outputs with reduced ripple.

  18. Converter of a continuous code into the Grey code

    International Nuclear Information System (INIS)

    Gonchar, A.I.; TrUbnikov, V.R.

    1979-01-01

    Described is a converter of a continuous code into the Grey code used in a 12-charged precision amplitude-to-digital converter to decrease the digital component of spectrometer differential nonlinearity to +0.7% in the 98% range of the measured band. To construct the converter of a continuous code corresponding to the input signal amplitude into the Grey code used is the regularity in recycling of units and zeroes in each discharge of the Grey code in the case of a continuous change of the number of pulses of a continuous code. The converter is constructed on the elements of 155 series, the frequency of continuous code pulse passing at the converter input is 25 MHz

  19. The effect of daily sedation interruption protocol on early incidence of ventilator-associated pneumonia among patients hospitalized in critical care units receiving mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Mehdi Shahabi

    2016-01-01

    Full Text Available Background: Ventilator-associated pneumonia (VAP is a common side effect in patients who receive intravenous sedation infusion. In routine care, after starting sedation infusion for patients who receive mechanical ventilation, interruption of sedation starts without protocol. This study aimed to evaluate the effect of daily sedation vacation protocol on the incidence of VAP in mechanically ventilated patients. Materials and Methods: In this clinical trial study, 80 patients with intravenous sedation infusion were selected and randomly allocated to intervention and control groups. In the intervention group, daily sedation vacation protocol and in the control group, routine sedation vacation was followed. Modified clinical pulmonary infection score questionnaire was completed before intervention and on the third, fourth, and fifth days after intervention. Data were analyzed by using repeated measures analysis of variance (ANOVA, Chi-square, and independent t-test. Results: The results of this study showed that the incidence rate of VAP in the intervention and control groups was 0% versus 15% on the third day of intervention, 12.5% versus 50% on the fourth day, and 27.5% versus 55.3% on the fifth day of intervention in the intervention and control groups, respectively. The incidence of VAP in the intervention group was significantly lower than in the control group (P < 0.05. Conclusions: The results of this study showed that in patients with intravenous sedation, infusion of a daily sedation vacation protocol may reduce the incidence of VAP. Therefore, in order to prevent VAP, nurses are recommended to use this daily sedation vacation protocol.

  20. Radiation tolerant power converter controls

    CERN Document Server

    Todd, B; King, Q; Uznanski, S

    2012-01-01

    The Large Hadron Collider (LHC) at the European Organisation for Nuclear Research (CERN) is the world's most powerful particle collider. The LHC has several thousand magnets, both warm and super-conducting, which are supplied with current by power converters. Each converter is controlled by a purpose-built electronic module called a Function Generator Controller (FGC). The FGC allows remote control of the power converter and forms the central part of a closed-loop control system where the power converter voltage is set, based on the converter output current and magnet-circuit characteristics. Some power converters and FGCs are located in areas which are exposed to beam-induced radiation. There are numerous radiation induced effects, some of which lead to a loss of control of the power converter, having a direct impact upon the accelerator's availability. Following the first long shut down (LS1), the LHC will be able to run with higher intensity beams and higher beam energy. This is expected to lead to signifi...

  1. Thyristor voltage converter in induction electric drives with microprocessor control

    Energy Technology Data Exchange (ETDEWEB)

    Braslavsky, I.; Zuzev, A.; Shilin, S. [Electric Drive Department, Urals State Technical University, Ekaterinburg (Russian Federation)

    1997-12-31

    The paper consists of some results on developed pulse model of thyristor voltage converter which is one of the most mathematically complicated unit of electric drive. The model structure and model parameter calculating method are represented. The application of the model allows to analyse stability in `locally` by the linear pulse system theory methods with talking into consideration quantise processes within the converter. Such application provides the obtaining higher accurate results comparing with the non-linear system theory approximate methods. Logarithmic frequency characteristics are used to analyse converter dynamic features and they are represented too. (orig.) 4 refs.

  2. Advanced DC/DC converters

    CERN Document Server

    Luo, Fang Lin

    2003-01-01

    DC/DC conversion techniques have undergone rapid development in recent decades. With the pioneering work of these authors, DC/DC converters have now moved into their sixth generation. This book offers a concise, practical presentation of DC/DC converters, summarizing the spectrum of conversion tecnologies and presentingmany new ideas and more than 100 new topologies. Nowhere else in the literature are DC/DC converters so logically sorted and systematically introduced, and nowhere else can readers find detailed information on prototype topologies that represent a major contribution to modern power engineering. More than 320 figures, 60 tables, and 500 formulae facilitate understand and provide precise data.

  3. Time-to-digital converters

    CERN Document Server

    Henzler, Stephan

    2010-01-01

    This text covers the fundamentals of time-to-digital converters on analog and digital conversion principles. It includes a theoretical investigation into quantization, linearity, noise and variability, and it details a range of advanced TDC architectures.

  4. Transformerless dc-Isolated Converter

    Science.gov (United States)

    Rippel, Wally E.

    1987-01-01

    Efficient voltage converter employs capacitive instead of transformer coupling to provide dc isolation. Offers buck/boost operation, minimal filtering, and low parts count, with possible application in photovoltaic power inverters, power supplies and battery charges. In photovoltaic inverter circuit with transformerless converter, Q2, Q3, Q4, and Q5 form line-commutated inverter. Switching losses and stresses nil because switching performed when current is zero.

  5. Picosecond image-converter diagnostics

    International Nuclear Information System (INIS)

    Schelev, M.Ya.

    1975-01-01

    A brief review is presented of the improvements in picosecond image-converter diagnostics carried out since the previous Congress in 1972. The account is given under the following headings: picosecond image converter cameras for visible and x-ray radiation diagnostics; Nd:glass and ruby mode-locked laser measurements; x-ray plasma emission diagnostics; computer treatment of pictures produced by picosecond cameras. (U.K.)

  6. Cryptographic Protocols:

    DEFF Research Database (Denmark)

    Geisler, Martin Joakim Bittel

    cryptography was thus concerned with message confidentiality and integrity. Modern cryptography cover a much wider range of subjects including the area of secure multiparty computation, which will be the main topic of this dissertation. Our first contribution is a new protocol for secure comparison, presented...... implemented the comparison protocol in Java and benchmarks show that is it highly competitive and practical. The biggest contribution of this dissertation is a general framework for secure multiparty computation. Instead of making new ad hoc implementations for each protocol, we want a single and extensible...... in Chapter 2. Comparisons play a key role in many systems such as online auctions and benchmarks — it is not unreasonable to say that when parties come together for a multiparty computation, it is because they want to make decisions that depend on private information. Decisions depend on comparisons. We have...

  7. Estimation of the influence of the early termination of the operation of units 1- 4 in NPP Kozloduy on the greenhouse gas emissions and the obligations of Republic of Bulgaria regarding the Kyoto Protocol

    International Nuclear Information System (INIS)

    Christov, Chr.; Vasilev, Hr.

    2003-01-01

    The case of early termination of the operation of units 1 - 4 in NPP 'Kozloduy' would have a considerable impact on the greenhouse gas (GHG) emissions because in the structure of the electricity production the nuclear power plant occupies over 40%. Due to decrease of the share of the nuclear energy in the electricity production the share of the solid and gaseous fuels increases. They are a considerable source of GHG. Three scenarios for the development of the electric power sector until year 2015 have been studied for the case of early termination of the operation of units 1 - 4 in NPP: Scenario 1: Early termination of the operation of units 1 - 4 according to terms pointed out by the EU. Scenario 2: Decommissioning of units 1 - 4 according to term in the project design. Scenario 3: Early termination of the operation of units 1 - 2 according to terms pointed out by the EU and decommissioning of units 3 - 4 according to terms in the project design. Comparative calculations have been performed for the forecasted GHG emission quantities in the first commitment period of the Kyoto Protocol (2008 - 2012). The potential for possible quantities of GHG emissions that could be traded during the entire five-year period are estimated. At minimum possible price of the emissions 5 $US/tCO 2 the annual income will be at least 100 - 130 mill $US. The realistic estimation regarding the omitted benefits due to early termination of the operation of units 1 - 4 is about 900 mill $US for the five year period of Kyoto. The continued operation of units 3 - 4 to the end of the term defined in the project design could make it possible to fulfill an income of 700 mill to 1 billion $US from emission trading

  8. GPS Synchronization of Smart Distributed Converters for Microgrid Applications

    Directory of Open Access Journals (Sweden)

    Tarek A. Youssef

    2018-03-01

    Full Text Available In this paper, a smart distributed DC/DC converter synchronization advanced technique and phase angle optimization algorithm are proposed using to reduce the DC bus overall ripple. A global positioning system-based scheme is used to synchronize the carrier among the distributed converters. The carrier phase angle optimization among the different converters is inspired by Carrier-Sense Multiple Access protocol. The proposed system is simulated and analyzed using Matlab/Simulink program. As a proof of concept of the proposed technique, two case studies have been investigated under equal and unequal load sharing among the distributed generators. The proposed algorithm shows a significant reduction in the DC bus voltage ripple. To prove the concept, a laboratory test-bed has been built and the proposed algorithm has been implemented to validate the theoretical and simulation results. The close agreement between the experimental and simulation results demonstrates the effectiveness and validity of the proposed algorithm.

  9. Analysis and Design of High-Order Parallel Resonant Converters

    Science.gov (United States)

    Batarseh, Issa Eid

    1990-01-01

    In this thesis, a special state variable transformation technique has been derived for the analysis of high order dc-to-dc resonant converters. Converters comprised of high order resonant tanks have the advantage of utilizing the parasitic elements by making them part of the resonant tank. A new set of state variables is defined in order to make use of two-dimensional state-plane diagrams in the analysis of high order converters. Such a method has been successfully used for the analysis of the conventional Parallel Resonant Converters (PRC). Consequently, two -dimensional state-plane diagrams are used to analyze the steady state response for third and fourth order PRC's when these converters are operated in the continuous conduction mode. Based on this analysis, a set of control characteristic curves for the LCC-, LLC- and LLCC-type PRC are presented from which various converter design parameters are obtained. Various design curves for component value selections and device ratings are given. This analysis of high order resonant converters shows that the addition of the reactive components to the resonant tank results in converters with better performance characteristics when compared with the conventional second order PRC. Complete design procedure along with design examples for 2nd, 3rd and 4th order converters are presented. Practical power supply units, normally used for computer applications, were built and tested by using the LCC-, LLC- and LLCC-type commutation schemes. In addition, computer simulation results are presented for these converters in order to verify the theoretical results.

  10. Two-inductor boost and buck converters

    Science.gov (United States)

    White, J. L.; Muldoon, W. J.

    The derivation, analysis and design of a coupled inductor boost converter is presented. Aspects of the qualitative ac behavior of coupled inductor converters are discussed. Considerations for the design of the magnetics for such converters are addressed.

  11. Immunochemical protocols

    National Research Council Canada - National Science Library

    Pound, John D

    1998-01-01

    ... easy and important refinements often are not published. This much anticipated 2nd edition of Immunochemzcal Protocols therefore aims to provide a user-friendly up-to-date handbook of reliable techniques selected to suit the needs of molecular biologists. It covers the full breadth of the relevant established immunochemical methods, from protein blotting and immunoa...

  12. Early Oscillation Detection for DC/DC Converter Fault Diagnosis

    Science.gov (United States)

    Wang, Bright L.

    2011-01-01

    The electrical power system of a spacecraft plays a very critical role for space mission success. Such a modern power system may contain numerous hybrid DC/DC converters both inside the power system electronics (PSE) units and onboard most of the flight electronics modules. One of the faulty conditions for DC/DC converter that poses serious threats to mission safety is the random occurrence of oscillation related to inherent instability characteristics of the DC/DC converters and design deficiency of the power systems. To ensure the highest reliability of the power system, oscillations in any form shall be promptly detected during part level testing, system integration tests, flight health monitoring, and on-board fault diagnosis. The popular gain/phase margin analysis method is capable of predicting stability levels of DC/DC converters, but it is limited only to verification of designs and to part-level testing on some of the models. This method has to inject noise signals into the control loop circuitry as required, thus, interrupts the DC/DC converter's normal operation and increases risks of degrading and damaging the flight unit. A novel technique to detect oscillations at early stage for flight hybrid DC/DC converters was developed.

  13. Modeling of asymmetrical boost converters

    Directory of Open Access Journals (Sweden)

    Eliana Isabel Arango Zuluaga

    2014-01-01

    Full Text Available The asymmetrical interleaved dual boost (AIDB is a fifth-order DC/DC converter designed to interface photovoltaic (PV panels. The AIDB produces small current harmonics to the PV panels, reducing the power losses caused by the converter operation. Moreover, the AIDB provides a large voltage conversion ratio, which is required to step-up the PV voltage to the large dc-link voltage used in grid-connected inverters. To reject irradiance and load disturbances, the AIDB must be operated in a closed-loop and a dynamic model is required. Given that the AIDB converter operates in Discontinuous Conduction Mode (DCM, classical modeling approaches based on Continuous Conduction Mode (CCM are not valid. Moreover, classical DCM modeling techniques are not suitable for the AIDB converter. Therefore, this paper develops a novel mathematical model for the AIDB converter, which is suitable for control-pur-poses. The proposed model is based on the calculation of a diode current that is typically disregarded. Moreover, because the traditional correction to the second duty cycle reported in literature is not effective, a new equation is designed. The model accuracy is contrasted with circuital simulations in time and frequency domains, obtaining satisfactory results. Finally, the usefulness of the model in control applications is illustrated with an application example.

  14. Unified Digital Periodic Signal Filters for Power Converter Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Xin, Zhen; Zhou, Keliang

    2017-01-01

    Periodic signal controllers like repetitive and resonant controllers have demonstrated much potential in the control of power electronic converters, where periodic signals (e.g., ac voltages and currents) can be precisely regulated to follow references. Beyond the control of periodic signals, ac...... signal processing (e.g., in synchronization and pre-filtering) is also very important for power converter systems. Hence, this paper serves to unify digital periodic signal filters so as to maximize their roles in power converter systems (e.g., enhance the control of ac signals). The unified digital...... periodic signal filters behave like a comb filter, but it can also be configured to selectively filter out the harmonics of interest (e.g., the odd-order harmonics in single-phase power converter systems). Moreover, a virtual variable-sampling-frequency unit delay that enables frequency adaptive periodic...

  15. A collimator-converter system for IEC propulsion

    International Nuclear Information System (INIS)

    Momota, Hiromu; Miley, George H.

    2002-01-01

    The collimator-converter system extracts fusion power from D- 3 He fueled IEC devices and provides electricity needed to operate ionic thrusters and other-power components. The whole system is linear and consists of a series of collimator units at the center, magnetic expander units at both sides of the fusion units, followed by direct energy converters at both ends. This system is enclosed in a vacuum chamber with a magnetic channel provided by magnetic solenoids out of respective chambers. The fusion unit consists of an IEC fusion core, a pair of coils anti-parallel to the solenoid coils, and a stabilization coil that stabilizes the position of coil pair coils. The IEC fusion core is installed at the center of the pair coils. After the magnetic expander, velocities of fusion particles from D- 3 He fueled IEC units are directed to the magnetic channel, which guides energetic fusion particles as well as leaking unburned fuel components to a high-efficiency traveling wave direct energy converter (TWDEC). Leaking unburned fuel components are separated with a magnetic separator at the entrance of a direct energy converter and pumped out for further refueling. A TWDEC is made of an array of metallic meshed grids, each of which is connected to every terminal with an external transmission circuit. The transmission line couples to the direct energy converter. Substations for electricity, a cryogenic plant, and various power control systems are outside of the vacuum chamber. The length of the cylindrical system is essentially determined by the proton energy of 14.8 MeV and the radius should be large so as to reduce power flow density. The present system provides 250 MW f fusion power and converting it to 150 MW c electricity. Its size is 150 m(length)x6.6 m(diameter) in size and 185 tons in weight

  16. Entanglement in a parametric converter

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Su-Yong; Qamar, Shahid; Lee, Hai-Woong; Zubairy, M Suhail [Center for Quantum Physics, COMSATS Institute of Information Technology, Islamabad (Pakistan)], E-mail: shahid_qamar@pieas.edu.pk, E-mail: zubairy@physics.tamu.edu

    2008-07-28

    In this paper, we consider a parametric converter as a source of entangled radiation. We examine recently derived conditions (Hillery and Zubairy 2006 Phys. Rev. Lett. 96 050503, Duan et al 2000 Phys. Rev. Lett. 84 2722) for determining when the two output modes in a parametric converter are entangled. We show that for different initial field states, the two criteria give different conditions that ensure that the output states are entangled. We also present an input-output calculation for the entanglement of the output field.

  17. Necessary and sufficient condition for distillability with unit fidelity from finite copies of a mixed state: The most efficient purification protocol

    International Nuclear Information System (INIS)

    Chen Pingxing; Liang Linmei; Li Chengzu; Huang Mingqiu

    2002-01-01

    It is well known that any entangled mixed state in 2x2 systems can be purified via infinite copies of the mixed state. But, can one distill a pure maximally entangled state from finite copies of a mixed state in any bipartite system by local operation and classical communication? This is more meaningful in practical application. We give a necessary and sufficient condition for this distillability. This condition requires that there exist distillable subspaces. According to this condition, one can judge easily whether a mixed state is distillable or not. We also analyze some properties of distillable subspaces, and discuss the most efficient purification protocol. Finally, we discuss the distillable enanglement of a two-qubit system for the case of finite copies

  18. AC-DC PFC Converter Using Combination of Flyback Converter and Full-bridge DC-DC Converter

    Directory of Open Access Journals (Sweden)

    Moh. Zaenal Efendi

    2014-06-01

    Full Text Available This paper presents a combination of power factor correction converter using Flyback converter and Full-bridge dc-dc converter in series connection. Flyback converter is operated in discontinuous conduction mode so that it can serve as a power factor correction converter and meanwhile Full-bridge dc-dc converter is used for dc regulator. This converter system is designed to produce a 86 Volt of output voltage and 2 A of output current. Both simulation and experiment results show that the power factor of this converter achieves up to 0.99 and meets harmonic standard of IEC61000-3-2. Keywords: Flyback Converter, Full-bridge DC-DC Converter, Power Factor Correction.

  19. Time-to-code converter with selection of time intervals on duration

    International Nuclear Information System (INIS)

    Atanasov, I.Kh.; Rusanov, I.R.; )

    2001-01-01

    Identification of elementary particles on the basis of time-of-flight represents the important approach of the preliminary selection procedure. Paper describes a time-to-code converter with preliminary selection of the measured time intervals as to duration. It consists of a time-to-amplitude converter, an analog-to-digital converter, a unit of selection of time intervals as to duration, a unit of total reset and CAMAC command decoder. The time-to-code converter enables to measure time intervals with 100 ns accuracy within 0-100 ns range. Output code capacity is of 10. Selection time constitutes 50 ns [ru

  20. Current-to-frequency converter

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W [Institute of Nuclear Research, Warsaw (Poland)

    1981-07-15

    A current-to-frequency converter covering the range from 3 x 10/sup -10/ A up to 3 x 10/sup -5/ A of the input current is described. The circuit operates with nuclear detectors featuring a high internal resistance.

  1. Materials for thermionic energy converters

    NARCIS (Netherlands)

    Wolff, L.R.; Hermans, J.M.; Adriaansen, J.K.M.; Gubbels, G.H.M.; Vincenzini, P.

    1987-01-01

    This paper deals with the design and construction of a combustion heated Thermionic Energy Converter (TEC). Main components of this TEC are: 1. A ''Hot Shell'' protecting the TEC from the combustion environment 2. A ''Ceramic Seal'' electrically insulating the emitter from the collector 3. A

  2. Smart AD and DA Converters

    NARCIS (Netherlands)

    Roermund, van A.H.M.; Hegt, J.A.; Harpe, P.J.A.; Radulov, G.I.; Zanikopoulos, A.; Doris, K.; Quinn, P.J.

    2005-01-01

    In this paper, a concept is proposed to solve the problems related to the embedding of AD and DA converters in system-on-chips, FPGAs or other VLSI solutions. Problems like embedded testing, yield, reliability and reduced design space become crucial bottlenecks in the integration of high-performance

  3. Charge-pump voltage converter

    Science.gov (United States)

    Brainard, John P [Albuquerque, NM; Christenson, Todd R [Albuquerque, NM

    2009-11-03

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  4. Impedance interactions in bidirectional cascaded converter

    DEFF Research Database (Denmark)

    Tian, Yanjun; Loh, Poh Chiang; Chen, Zhe

    2016-01-01

    A cascaded converter is built by connecting one elementary converter to another. Output impedance of one converter will therefore interact with input impedance of the other converter. This interaction will change when power flow reverses. To compare this difference, an investigation is performed...

  5. Protocol Additional to the Agreement between the United Mexican States and the International Atomic Energy Agency for the Application of Safeguards in Connection with the Treaty for the Prohibition of Nuclear Weapons in Latin America and the Treaty on the Non-Proliferation of Nuclear Weapons

    International Nuclear Information System (INIS)

    2011-01-01

    The text of the Protocol Additional to the Agreement between the United Mexican States and the International Atomic Energy Agency for the Application of Safeguards in Connection with the Treaty for the Prohibition of Nuclear Weapons in Latin America and the Treaty on the Non-Proliferation of Nuclear Weapons is reproduced in this document for the information of all Members. The Board of Governors approved the Additional Protocol on 9 March 2004. It was signed on 29 March 2004 in Vienna, Austria. Pursuant to Article 17 of the Additional Protocol, the Protocol entered into force on 4 March 2011, the date on which the Agency received from the United Mexican States written notification that Mexico's statutory and constitutional requirements for entry into force had been met

  6. Modeling and Control of Primary Parallel Isolated Boost Converter

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Hernandez Botella, Juan Carlos; Sen, Gökhan

    2012-01-01

    In this paper state space modeling and closed loop controlled operation have been presented for primary parallel isolated boost converter (PPIBC) topology as a battery charging unit. Parasitic resistances have been included to have an accurate dynamic model. The accuracy of the model has been...

  7. Parametric study of laser photovoltaic energy converters

    Science.gov (United States)

    Walker, G. H.; Heinbockel, J. H.

    1987-01-01

    Photovoltaic converters are of interest for converting laser power to electrical power in a space-based laser power system. This paper describes a model for photovoltaic laser converters and the application of this model to a neodymium laser silicon photovoltaic converter system. A parametric study which defines the sensitivity of the photovoltaic parameters is described. An optimized silicon photovoltaic converter has an efficiency greater than 50 percent for 1000 W/sq cm of neodymium laser radiation.

  8. Bidirectional dc-to-dc Power Converter

    Science.gov (United States)

    Griesbach, C. R.

    1986-01-01

    Solid-state, series-resonant converter uses high-voltage thyristors. Converter used either to convert high-voltage, low-current dc power to lowvoltage, high current power or reverse. Taking advantage of newly-available high-voltage thyristors to provide better reliability and efficiency than traditional converters that use vacuum tubes as power switches. New converter essentially maintenance free and provides greatly increased mean time between failures. Attractive in industrial applications whether or not bidirectional capability is required.

  9. Patient and family satisfaction levels in the intensive care unit after elective cardiac surgery: study protocol for a randomised controlled trial of a preoperative patient education intervention

    OpenAIRE

    Lai, Veronica Ka Wai; Lee, Anna; Leung, Patricia; Chiu, Chun Hung; Ho, Ka Man; Gomersall, Charles David; Underwood, Malcolm John; Joynt, Gavin Matthew

    2016-01-01

    Introduction Patients and their families are understandably anxious about the risk of complications and unfamiliar experiences following cardiac surgery. Providing information about postoperative care in the intensive care unit (ICU) to patients and families may lead to lower anxiety levels, and increased satisfaction with healthcare. The objectives of this study are to evaluate the effectiveness of preoperative patient education provided for patients undergoing elective cardiac surgery. Meth...

  10. Fitness and mobility training in patients with Intensive Care Unit-acquired muscle weakness (FITonICU): study protocol for a randomised controlled trial

    OpenAIRE

    Mehrholz, Jan; Thomas, Simone; Burridge, Jane H.; Schmidt, Andr?; Scheffler, Bettina; Schellin, Ralph; R?ckriem, Stefan; Mei?ner, Daniel; Mehrholz, Katja; Sauter, Wolfgang; Bodechtel, Ulf; Elsner, Bernhard

    2016-01-01

    Background Critical illness myopathy (CIM) and polyneuropathy (CIP) are a common complication of critical illness. Both cause intensive-care-unit-acquired (ICU-acquired) muscle weakness (ICUAW) which increases morbidity and delays rehabilitation and recovery of activities of daily living such as walking ability. Focused physical rehabilitation of people with ICUAW is, therefore, of great importance at both an individual and a societal level. A recent systematic Cochrane review found no random...

  11. Study protocol

    DEFF Research Database (Denmark)

    Smith, Benjamin E; Hendrick, Paul; Bateman, Marcus

    2017-01-01

    avoidance behaviours, catastrophising, self-efficacy, sport and leisure activity participation, and general quality of life. Follow-up will be 3 and 6 months. The analysis will focus on descriptive statistics and confidence intervals. The qualitative components will follow a thematic analysis approach....... DISCUSSION: This study will evaluate the feasibility of running a definitive large-scale trial on patients with patellofemoral pain, within the NHS in the UK. We will identify strengths and weaknesses of the proposed protocol and the utility and characteristics of the outcome measures. The results from...... this study will inform the design of a multicentre trial. TRIAL REGISTRATION: ISRCTN35272486....

  12. Ultra-wideband reflective polarization converter based on anisotropic metasurface

    Science.gov (United States)

    Wu, Jia-Liang; Lin, Bao-Qin; Da, Xin-Yu

    2016-08-01

    In this paper, we propose an ultra-wideband reflective linear cross-polarization converter based on anisotropic metasurface. Its unit cell is composed of a square-shaped resonator with intersectant diagonal and metallic ground sheet separated by dielectric substrate. Simulated results show that the converter can generate resonances at four frequencies under normal incident electromagnetic (EM) wave, leading to the bandwidth expansion of cross-polarization reflection. For verification, the designed polarization converter is fabricated and measured. The measured and simulated results agree well with each other, showing that the fabricated converter can convert x- or y-polarized incident wave into its cross polarized wave in a frequency range from 7.57 GHz to 20.46 GHz with a relative bandwidth of 91.2%, and the polarization conversion efficiency is greater than 90%. The proposed polarization converter has a simple geometry but an ultra wideband compared with the published designs, and hence possesses potential applications in novel polarization-control devices. Project supported by the National Natural Science Foundation of China (Grant Nos. 61471387, 61271250, and 61571460).

  13. Ultra-wideband reflective polarization converter based on anisotropic metasurface

    International Nuclear Information System (INIS)

    Wu Jia-Liang; Lin Bao-Qin; Da Xin-Yu

    2016-01-01

    In this paper, we propose an ultra-wideband reflective linear cross-polarization converter based on anisotropic metasurface. Its unit cell is composed of a square-shaped resonator with intersectant diagonal and metallic ground sheet separated by dielectric substrate. Simulated results show that the converter can generate resonances at four frequencies under normal incident electromagnetic (EM) wave, leading to the bandwidth expansion of cross-polarization reflection. For verification, the designed polarization converter is fabricated and measured. The measured and simulated results agree well with each other, showing that the fabricated converter can convert x - or y -polarized incident wave into its cross polarized wave in a frequency range from 7.57 GHz to 20.46 GHz with a relative bandwidth of 91.2%, and the polarization conversion efficiency is greater than 90%. The proposed polarization converter has a simple geometry but an ultra wideband compared with the published designs, and hence possesses potential applications in novel polarization-control devices. (paper)

  14. New Zealand's Fourth National Communication under the United Nations Framework Convention on Climate Change. Including the Report on the Global Climate Observing System and the Report on Demonstrable Progress under the Kyoto Protocol

    International Nuclear Information System (INIS)

    2006-03-01

    The New Zealand Government is committed to playing its part in the global response to climate change. This Fourth National Communication provides a snapshot of New Zealand's progress with implementing the United Nations Framework Convention on Climate Change (UNFCCC). This document covers the period from the submission of the Third National Communication in January 2002 through to the end of December 2005. This document also contains New Zealand's Report on the Global Climate Observing System and the Report on Demonstrable Progress under the Kyoto Protocol. New Zealand's response to climate change has evolved substantially since the Third National Communication was submitted. On 19 December 2002, New Zealand became the 101st nation to ratify the Kyoto Protocol. In 2002, the New Zealand Parliament passed the Climate Change Response Act. This Act established a New Zealand climate change registry and corresponding institutional arrangements in accordance with Kyoto Protocol requirements. Other achievements are detailed throughout this Fourth National Communication. When the Government introduced its climate change policy package in 2002, it anticipated there would be three reviews of the package not later than 2005, 2007 and 2010. The reviews would be necessary to monitor progress with emissions reductions, assess the effectiveness of policies, and confirm that New Zealand was positioned to meet its commitments. The first of these reviews was commissioned by the Government in mid-2005 and completed by November 2005. The review concluded that some elements of the Government's 2002 climate change policy package should be modified to better position New Zealand to respond to the longer-term challenges of climate change. A key outcome of the policy review was the announcement by the newly elected Government in December 2005 that the previously announced carbon tax would not proceed. In addition, a suite of future work programmes would be required to inform Government

  15. Radiated EMI from power converters

    Directory of Open Access Journals (Sweden)

    Arnautovski-Toševa Vesna

    2005-01-01

    Full Text Available With the continuous increase of switching frequency together with the ongoing trend to higher complexity and functionality, power converters as a part of electronic systems have raised more and more electromagnetic energy pollution to the local system environment. In the same time, stringent demands are imposed on the designers of new circuits that electromagnetic interference (EMI has to be suppressed at its source before it is allowed to propagate into other circuits and systems. In this paper, the authors present a full-wave numerical method for calculation and simulation of electromagnetic field radiated by power converter circuitry. The main objective is to analyze the layout geometry in order to obtain competitive PCB layout that will enable suitably attenuated level of the radiated electric field to safe level. By this it would be possible to ensure reliable operation of the sensitive electronic components in the proximity.

  16. Vibration converter with magnetic levitation

    Science.gov (United States)

    Gladilin, A. V.; Pirogov, V. A.; Golyamina, I. P.; Kulaev, U. V.; Kurbatov, P. A.; Kurbatova, E. P.

    2015-05-01

    The paper presents a mathematical model, the results of computational and theoretical research, and the feasibility of creating a vibration converter with full magnetic levitation in the suspension of a high-temperature superconductor (HTSC). The axial and radial stability of the active part of the converter is provided by the interaction of the magnetic field of ring-shaped permanent magnets and a hollow cylinder made of the ceramic HTSC material. The force is created by a system of current-carrying coils whose magnetic field is polarized by permanent magnets and interacts with induced currents in the superconducting cylinder. The case of transition to the superconducting state of HTSC material in the field of the permanent magnets (FC mode) is considered. The data confirm the outlook for the proposed technical solutions.

  17. Status of advanced bremsstrahlung converters

    International Nuclear Information System (INIS)

    Halbleib, J.A.

    1980-01-01

    This paper is an attempt to review the somewhat ill-defined area of advanced converter research in a more or less chronological fashion. Section 2 reviews the early B/sub z/ work that was motivated by the CASINO project. More recent work makes liberal use of technology from ICF research using REBs is discussed in Sec. 3. Section 4 discusses possible directions for future research, some of which are being actively pursued at Sandia National Laboratories (SNL) and elsewhere

  18. Computerized simulation of converter process

    Energy Technology Data Exchange (ETDEWEB)

    Jalkanen, H; Suomi, M L; Wallgren, M [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Metallurgy

    1997-12-31

    Converter process is essentially an oxidising refining process aiming in addition to (1) the primary refining action, decarburisation of high carbon iron melt, also to (2) maximal elimination of impurity elements, especially silicon, phosphorus and sulphur, (3) melting of substantial amounts of scrap using the extra heat released in oxidation reactions and (4) to exact final steel temperature control, optimal for further treatments. `Quantitative modelling of such a complex non-stationary chemical process as oxygen converting necessitates extensive formulation of chemical and thermal evolution of the process in connection with the technological properties of the reactor and the process control measures. A comprehensive converter simulation program like CONSIM-3. 1 and its preceding versions that is based on the theoretical and practical knowledge on the process can be used for (1) educating specialists and smelter personnel, (2) planning of the blowing programs, (3) developing and testing of process control systems and after some elaboration and restructuring (4) it can be integrated to static or dynamic process control systems. (orig.) SULA 2 Research Programme; 10 refs.

  19. Computerized simulation of converter process

    Energy Technology Data Exchange (ETDEWEB)

    Jalkanen, H.; Suomi, M.L.; Wallgren, M. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Metallurgy

    1996-12-31

    Converter process is essentially an oxidising refining process aiming in addition to (1) the primary refining action, decarburisation of high carbon iron melt, also to (2) maximal elimination of impurity elements, especially silicon, phosphorus and sulphur, (3) melting of substantial amounts of scrap using the extra heat released in oxidation reactions and (4) to exact final steel temperature control, optimal for further treatments. `Quantitative modelling of such a complex non-stationary chemical process as oxygen converting necessitates extensive formulation of chemical and thermal evolution of the process in connection with the technological properties of the reactor and the process control measures. A comprehensive converter simulation program like CONSIM-3. 1 and its preceding versions that is based on the theoretical and practical knowledge on the process can be used for (1) educating specialists and smelter personnel, (2) planning of the blowing programs, (3) developing and testing of process control systems and after some elaboration and restructuring (4) it can be integrated to static or dynamic process control systems. (orig.) SULA 2 Research Programme; 10 refs.

  20. Development of a Compact Matrix Converter

    Directory of Open Access Journals (Sweden)

    J. Bauer

    2009-01-01

    Full Text Available This paper deals with the development of a matrix converter. Matrix converters belong to the category of direct frequency converters. A converter does not contain DC-link and the output voltage is provided by direct switching of voltage from the input phases. This is enabled by 9 bidirectional switches, which are provided by anti-serial connection of 18 IGBT transistors. The absence of a DC-link is great advantage of the matrix converter, but it also increases the requirements on the converter control. For this reason a new prototype of a matrix converter is being developed with sophisticated modern components (FPGA, Power PC equipped in the control part of the converter. The converter will be used for testing new control algorithms and commutation methods. 

  1. Preventive nebulization of mucolytic agents and bronchodilating drugs in invasively ventilated intensive care unit patients (NEBULAE): study protocol for a randomized controlled trial.

    Science.gov (United States)

    van der Hoeven, Sophia M; Binnekade, Jan M; de Borgie, Corianne A J M; Bosch, Frank H; Endeman, Henrik; Horn, Janneke; Juffermans, Nicole P; van der Meer, Nardo J M; Merkus, Maruschka P; Moeniralam, Hazra S; van Silfhout, Bart; Slabbekoorn, Mathilde; Stilma, Willemke; Wijnhoven, Jan Willem; Schultz, Marcus J; Paulus, Frederique

    2015-09-02

    Preventive nebulization of mucolytic agents and bronchodilating drugs is a strategy aimed at the prevention of sputum plugging, and therefore atelectasis and pneumonia, in intubated and ventilated intensive care unit (ICU) patients. The present trial aims to compare a strategy using the preventive nebulization of acetylcysteine and salbutamol with nebulization on indication in intubated and ventilated ICU patients. The preventive nebulization of mucolytic agents and bronchodilating drugs in invasively ventilated intensive care unit patients (NEBULAE) trial is a national multicenter open-label, two-armed, randomized controlled non-inferiority trial in the Netherlands. Nine hundred and fifty intubated and ventilated ICU patients with an anticipated duration of invasive ventilation of more than 24 hours will be randomly assigned to receive either a strategy consisting of preventive nebulization of acetylcysteine and salbutamol or a strategy consisting of nebulization of acetylcysteine and/or salbutamol on indication. The primary endpoint is the number of ventilator-free days and surviving on day 28. Secondary endpoints include ICU and hospital length of stay, ICU and hospital mortality, the occurrence of predefined pulmonary complications (acute respiratory distress syndrome, pneumonia, large atelectasis and pneumothorax), and the occurrence of predefined side effects of the intervention. Related healthcare costs will be estimated in a cost-benefit and budget-impact analysis. The NEBULAE trial is the first randomized controlled trial powered to investigate whether preventive nebulization of acetylcysteine and salbutamol shortens the duration of ventilation in critically ill patients. NCT02159196, registered on 6 June 2014.

  2. Community acquired pneumonia in the elderly: the Pneumonia in Italian Acute Care for Elderly units (PIACE study protocol by the Italian Society of Hospital and Community Geriatrics (SIGOT

    Directory of Open Access Journals (Sweden)

    Filippo Luca Fimognari

    2017-01-01

    Full Text Available Pneumonia is a frequent cause of hospital admission in elderly patients. Diagnosis of pneumonia in elderly persons with comorbidity may be challenging, due to atypical presentation and complex clinical scenarios. Community-acquired pneumonia (CAP arises out-of-hospital in subjects without previous contact with the healthcare system. Healthcare associated pneumonia (HCAP occurs in patients who have frequent contacts with the healthcare system and should be treated with empiric broad spectrum antibiotic therapy also covering multi-drug resistant (MDR pathogens. Recent findings, however, have questioned this approach, because the worse prognosis of HCAP compared to CAP may better reflect increased level of comorbidity and frailty (poor functional status, older age of HCAP patients, as well as poorer quality of hospital care provided to such patients, rather than pneumonia etiology by MDR pathogens. The Pneumonia in Italian Acute Care for Elderly units (PIACE Study, promoted by the Società Italiana di Geriatria Ospedale e Territorio (SIGOT, is an observational prospective cohort study of patients consecutively admitted because of pneumonia to hospital acute care units of Geriatrics throughout Italy. Detailed information regarding clinical presentation, diagnosis, etiology, comprehensive geriatric assessment, antibiotic therapy, possible complications and comorbidities was recorded to identify factors potentially predicting in-hospital mortality (primary endpoint, 3-month mortality, length of hospital stay, postdischarge rate of institutionalization and other secondary endpoints. This paper describes the rationale and method of PIACE Study and reviews the main evidence on pneumonia in the elderly.

  3. Multi-party semi-quantum key distribution-convertible multi-party semi-quantum secret sharing

    Science.gov (United States)

    Yu, Kun-Fei; Gu, Jun; Hwang, Tzonelih; Gope, Prosanta

    2017-08-01

    This paper proposes a multi-party semi-quantum secret sharing (MSQSS) protocol which allows a quantum party (manager) to share a secret among several classical parties (agents) based on GHZ-like states. By utilizing the special properties of GHZ-like states, the proposed scheme can easily detect outside eavesdropping attacks and has the highest qubit efficiency among the existing MSQSS protocols. Then, we illustrate an efficient way to convert the proposed MSQSS protocol into a multi-party semi-quantum key distribution (MSQKD) protocol. The proposed approach is even useful to convert all the existing measure-resend type of semi-quantum secret sharing protocols into semi-quantum key distribution protocols.

  4. Acceleration experienced by thermal converter implanted in calves

    International Nuclear Information System (INIS)

    Koshino, I.; Sukalac, R.; Jacobs, G.; Kiraly, R.J.; Nose, Y.

    1976-02-01

    The objective of this study was to determine acceleration levels experienced by the ERDA thermal converter unit implanted abdominally in a calf. A full-scale weighted mock-up of the thermal converter was fabricated containing a triaxial accelerometer. The mock-up was implanted in calf cadavers which were subjected to falls from an operating table. Highest acceleration recorded was 34 g. The mock-up was implanted in living animals and acceleration measurements made under various maneuvers including walking, standing from a laying position, walking up and down stairs, jumping, and falling from a standing position. Maximum acceleration recorded was 8 g and occurred in the falling maneuver

  5. Simulation Results of Double Forward Converter

    Directory of Open Access Journals (Sweden)

    P. Vijaya KUMAR

    2009-12-01

    Full Text Available This work aims to find a better forward converter for DC to DC conversion.Simulation of double forward converter in SMPS system is discussed in this paper. Aforward converter with RCD snubber to synchronous rectifier and/or to current doubleris also discussed. The evolution of the forward converter is first reviewed in a tutorialfashion. Performance parameters are discussed including operating principle, voltageconversion ratio, efficiency, device stress, small-signal dynamics, noise and EMI. Itscircuit operation and its performance characteristics of the forward converter with RCDsnubber and double forward converter are described and the simulation results arepresented.

  6. Experimental follow-up of the Bois-Joly GAEC methanization installation - Global assessment, final report, Phase 2 - Unit follow-up protocol. Operation assessment of the Bois-Joly GAEC agricultural discontinuous dry methanization unit. The discontinuous dry process: lessons learned after 6 years of exploitation at the Bois-Joly GAEC

    International Nuclear Information System (INIS)

    Brosset, Denis; Pouech, Philippe; Guillet, Marie; Banville, Sandrine; Bastide, Guillaume; Thual, J.

    2008-06-01

    A first document reports the follow-up study of an existing methanization installation. This study comprises four phases. The first one is a general presentation of the installation. The second one addresses the determination of reference indicators and the definition of the follow-up protocol. The third one is an installation follow-up over two years. The report thus proposes a presentation of the exploitation principles and operation, technical data regarding the methanization installation, the definition of follow-up parameters, protocol and means. It reports the elaboration of technical, environmental and economic indicators, and proposes an analysis of the installation performance, assets and weaknesses while outlining interests and perspectives of a formatted follow-up of methanization installations. Appendices notably contain the phase 2 report related to the unit follow-up protocol, results of physical-chemical composition analyses and of performance tests, a synthetic report of the experimental follow-up. A Power Point presentation reports the operation assessment. Another one proposes a discussion of lessons learned after 6 years of operation of the studied installation and more particularly about its discontinuous dry process. Another Power Point comments the relationship between research and application in the case of this specific process. Two documents and leaflets present the installation and a synthetic report of its experimental follow-up

  7. Beyond protocols

    DEFF Research Database (Denmark)

    Vanderhoeven, Sonia; Branquart, Etienne; Casaer, Jim

    2017-01-01

    Risk assessment tools for listing invasive alien species need to incorporate all available evidence and expertise. Beyond the wealth of protocols developed to date, we argue that the current way of performing risk analysis has several shortcomings. In particular, lack of data on ecological impact...... information on risk and the exploration of improved methods for decision making on biodiversity management. This is crucial for efficient conservation resource allocation and uptake by stakeholders and the public......., transparency and repeatability of assessments as well as the incorporation of uncertainty should all be explicitly considered. We recommend improved quality control of risk assessments through formalized peer review with clear feedback between assessors and reviewers. Alternatively, a consensus building...

  8. The Annual American Men's Internet Survey of Behaviors of Men Who Have Sex With Men in the United States: Protocol and Key Indicators Report 2013.

    Science.gov (United States)

    Sanchez, Travis Howard; Sineath, R Craig; Kahle, Erin M; Tregear, Stephen James; Sullivan, Patrick Sean

    2015-01-01

    Men who have sex with men (MSM) are disproportionately affected by human immunodeficiency virus (HIV) and there is evidence that this population is participating in increasingly risky sexual behavior. These changes are occurring in the context of new modes of online social interaction-many MSM now report first meeting their sex partners on the Internet. Better monitoring of key behavioral indicators among MSM requires the use of surveillance strategies that capitalize on these new modes of interaction. Therefore, we developed an annual cross-sectional behavioral survey of MSM in the United States, the American Men's Internet Survey (AMIS). The purpose of this paper was to provide a description of AMIS methods. In addition we report on the first cycle of data collection (December 2013 through May 2014; AMIS-2013) on the same key indicators used for national HIV behavioral surveillance. AMIS-2013 recruited MSM from a variety of websites using banner advertisements or email blasts. Adult men currently residing in the United States were eligible to participate if they had ever had sex with a man. We examined demographic and recruitment characteristics using multivariable regression modeling (Prisk behaviors but were more likely to have been HIV tested. The first round of AMIS generated useful behavioral measures from more than 10,000 MSM Internet users. Preliminary findings identified some subgroups of MSM Internet users that are at potentially higher risk of HIV acquisition/transmission. AMIS will provide an ongoing data source for examining trends in sexual risk behavior of MSM. This will help to plan and monitor the impact of programs to improve this population's health.

  9. The Geneva Protocol of 1925

    International Nuclear Information System (INIS)

    Mc Elroy, R.J.

    1991-01-01

    This paper reports that when President Gerald Ford signed the instruments of ratification for the Geneva Protocol of 1925 on January 22, 1975, a tortured, half-century-long chapter in U.S. arms control policy was brought to a close. Fifty years earlier, at the Geneva Conference for the Control of the International Trade in Arms, Munitions and Implements of War, the United States had played a key role in drafting and reaching agreement on the Protocol for the Prohibition of the Use in War of Asphyxiating, Poisonous or Other Gases and of Bacteriological Methods of Warfare. The protocol, signed by thirty nations, including the United States, on June 17, 1925, prohibits the use in war of asphyxiating, poisonous or other gases, and of all analogous liquids, materials or devices as well as the use of bacteriological methods of warfare

  10. Results of metallographical diagnostic examination of Navy half-watt thermoelectric converters degraded by accelerated tests

    International Nuclear Information System (INIS)

    Rosell, F.E. Jr.; Rouklove, P.G.

    1977-01-01

    To verify the 15-year reliability of the Navy half-watt radioisotope thermoelectric generator (RTG), bismuth--telluride thermoelectric converters were submitted to testing at high temperatures which accelerated the degradation and caused failure of the converters. Metallographic diagnostic examination of failed units verified failure mechanisms. Results of diagnostic examinations are presented

  11. Method of stabilizing a laser apparatus with wavelength converter

    DEFF Research Database (Denmark)

    2013-01-01

    and to output the frequency-converted radiation (213), the frequency-converted radiation having at least a second wavelength different from the first wavelength, the diode laser (10) comprising at least a first and a second section (222,223), a first contact (220) for injecting a first current (I1......) into the first section (222), a second contact (221) for injecting a second current (I2) into the second section (223), and means for controlling a temperature of the diode laser; wherein the method comprises monitoring a first parameter indicative of the power content of a dominant lobe of the first radiation......A method of controlling beam quality and stability of a laser apparatus, the laser apparatus comprising, a diode laser (10) providing first radiation of at least a first wavelength, and a frequency conversion unit (12) configured to frequency-convert the first radiation from the diode laser...

  12. Auxiliary resonant DC tank converter

    Science.gov (United States)

    Peng, Fang Z.

    2000-01-01

    An auxiliary resonant dc tank (ARDCT) converter is provided for achieving soft-switching in a power converter. An ARDCT circuit is coupled directly across a dc bus to the inverter to generate a resonant dc bus voltage, including upper and lower resonant capacitors connected in series as a resonant leg, first and second dc tank capacitors connected in series as a tank leg, and an auxiliary resonant circuit comprising a series combination of a resonant inductor and a pair of auxiliary switching devices. The ARDCT circuit further includes first clamping means for holding the resonant dc bus voltage to the dc tank voltage of the tank leg, and second clamping means for clamping the resonant dc bus voltage to zero during a resonant period. The ARDCT circuit resonantly brings the dc bus voltage to zero in order to provide a zero-voltage switching opportunity for the inverter, then quickly rebounds the dc bus voltage back to the dc tank voltage after the inverter changes state. The auxiliary switching devices are turned on and off under zero-current conditions. The ARDCT circuit only absorbs ripples of the inverter dc bus current, thus having less current stress. In addition, since the ARDCT circuit is coupled in parallel with the dc power supply and the inverter for merely assisting soft-switching of the inverter without participating in real dc power transmission and power conversion, malfunction and failure of the tank circuit will not affect the functional operation of the inverter; thus a highly reliable converter system is expected.

  13. Electromechanical converters for electric vehicles

    Science.gov (United States)

    Ambros, T.; Burduniuc, M.; Deaconu, S. I.; Rujanschi, N.

    2018-01-01

    The paper presents the analysis of various constructive schemes of synchronous electromechanical converters with permanent magnets fixed on the rotor and asynchronous with the short-circuit rotor. Various electrical stator winding schemes have also been compared, demonstrating the efficiency of copper utilization in toroidal windings. The electromagnetic calculus of the axial machine has particularities compared to the cylindrical machine, in the paper is presented the method of correlating the geometry of the cylindrical and axial machines. In this case the method and recommendations used in the design of such machines may be used.

  14. Power electronics converters and regulators

    CERN Document Server

    Dokić, Branko L

    2015-01-01

    This book is the result of the extensive experience the authors gained through their year-long occupation at the Faculty of Electrical Engineering at the University of Banja Luka. Starting at the fundamental basics of electrical engineering, the book guides the reader into this field and covers all the relevant types of converters and regulators. Understanding is enhanced by the given examples, exercises and solutions. Thus this book can be used as a textbook for students, for self-study or as a reference book for professionals.

  15. Patient and family satisfaction levels in the intensive care unit after elective cardiac surgery: study protocol for a randomised controlled trial of a preoperative patient education intervention

    Science.gov (United States)

    Leung, Patricia; Chiu, Chun Hung; Ho, Ka Man; Gomersall, Charles David; Underwood, Malcolm John

    2016-01-01

    Introduction Patients and their families are understandably anxious about the risk of complications and unfamiliar experiences following cardiac surgery. Providing information about postoperative care in the intensive care unit (ICU) to patients and families may lead to lower anxiety levels, and increased satisfaction with healthcare. The objectives of this study are to evaluate the effectiveness of preoperative patient education provided for patients undergoing elective cardiac surgery. Methods and analysis 100 patients undergoing elective coronary artery bypass graft, with or without valve replacement surgery, will be recruited into a 2-group, parallel, superiority, double-blinded randomised controlled trial. Participants will be randomised to either preoperative patient education comprising of a video and ICU tour with standard care (intervention) or standard education (control). The primary outcome measures are the satisfaction levels of patients and family members with ICU care and decision-making in the ICU. The secondary outcome measures are patient anxiety and depression levels before and after surgery. Ethics and dissemination Ethical approval has been obtained from the Joint Chinese University of Hong Kong—New Territories East Cluster Clinical Research Ethics Committee (reference number CREC 2015.308). The findings will be presented at conferences and published in peer-reviewed journals. Study participants will receive a 1-page plain language summary of results. Trial registration number ChiCTR-IOR-15006971. PMID:27334883

  16. Assistance at mealtimes in hospital settings and rehabilitation units for older adults from the perspective of patients, families and healthcare professionals: a mixed methods systematic review protocol.

    Science.gov (United States)

    Edwards, Deborah; Carrier, Judith; Hopkinson, Jane

    2015-11-01

    The review question is: assistance at mealtimes for older adults in hospital settings and rehabilitation units: what goes on, what works and what do patients, families and healthcare professionals think about it?The specific objectives are:This mixed methods review seeks to develop an aggregated synthesis of quantitative and qualitative data on assistance at mealtimes for older adults in hospital settings and rehabilitation units in order to derive conclusions and recommendations useful for clinical practice and policy decision making. Worldwide, it is estimated that between 20% and 50% of all adult patients admitted to hospital wards are malnourished. Reported prevalence occurs, depending on the specific patient group of interest, type of healthcare setting, disease state and criteria used to assess malnutrition. For older adults in hospital (over 65 years) the prevalence of malnutrition has been reported as being as high as 60% and can continue to deteriorate during the hospital stay. This is an area of concern as it is associated with prolonged hospital stays and increased morbidity (pressure ulcers, infections and falls) and mortality, especially for those with chronic conditions.Malnutrition in adults in developed countries is frequently associated with disease and may occur because of reduced dietary intake, malabsorption, increased nutrient losses or altered metabolic demands, with reduced dietary intake being considered the single most important aetiological factor. For the hospitalized older adult patient with pre-existing malnutrition, further nutritional problems are often encountered due to a reduced dietary intake. Poor food intake for older patients in hospital may be due to the effects of acute illness, poor appetite, nausea or vomiting, "nil by mouth" orders, medication side effects, catering limitations, swallowing and/or oral problems, difficulty with vision and opening containers, the placement of food out of the patients' reach, limited access

  17. Patient and family satisfaction levels in the intensive care unit after elective cardiac surgery: study protocol for a randomised controlled trial of a preoperative patient education intervention.

    Science.gov (United States)

    Lai, Veronica Ka Wai; Lee, Anna; Leung, Patricia; Chiu, Chun Hung; Ho, Ka Man; Gomersall, Charles David; Underwood, Malcolm John; Joynt, Gavin Matthew

    2016-06-22

    Patients and their families are understandably anxious about the risk of complications and unfamiliar experiences following cardiac surgery. Providing information about postoperative care in the intensive care unit (ICU) to patients and families may lead to lower anxiety levels, and increased satisfaction with healthcare. The objectives of this study are to evaluate the effectiveness of preoperative patient education provided for patients undergoing elective cardiac surgery. 100 patients undergoing elective coronary artery bypass graft, with or without valve replacement surgery, will be recruited into a 2-group, parallel, superiority, double-blinded randomised controlled trial. Participants will be randomised to either preoperative patient education comprising of a video and ICU tour with standard care (intervention) or standard education (control). The primary outcome measures are the satisfaction levels of patients and family members with ICU care and decision-making in the ICU. The secondary outcome measures are patient anxiety and depression levels before and after surgery. Ethical approval has been obtained from the Joint Chinese University of Hong Kong-New Territories East Cluster Clinical Research Ethics Committee (reference number CREC 2015.308). The findings will be presented at conferences and published in peer-reviewed journals. Study participants will receive a 1-page plain language summary of results. ChiCTR-IOR-15006971. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. OAM mode converter in twisted fibers

    DEFF Research Database (Denmark)

    Usuga Castaneda, Mario A.; Beltran-Mejia, Felipe; Cordeiro, Cristiano

    2014-01-01

    We analyze the case of an OAM mode converter based on a twisted fiber, through finite element simulations where we exploit an equivalence between geometric and material transformations. The obtained converter has potential applications in MDM. © 2014 OSA.......We analyze the case of an OAM mode converter based on a twisted fiber, through finite element simulations where we exploit an equivalence between geometric and material transformations. The obtained converter has potential applications in MDM. © 2014 OSA....

  19. A new concept of thermionic converter

    International Nuclear Information System (INIS)

    Musa, G.

    1978-10-01

    The parameters of a new type of thermionic converter which has a number of concentric electrodes, is computed. The obtained theoretical efficiency of this new type of converter is nearly the efficiency of the ideal thermionic converter. The obtained results are explained by the reduction of the radiation loss from the emitter due to the electrode configuration. Efficiencies as high as 20% are expected from this type of converter now in construction. (author)

  20. Compiling symbolic attacks to protocol implementation tests

    Directory of Open Access Journals (Sweden)

    Michael Rusinowitch

    2013-07-01

    Full Text Available Recently efficient model-checking tools have been developed to find flaws in security protocols specifications. These flaws can be interpreted as potential attacks scenarios but the feasability of these scenarios need to be confirmed at the implementation level. However, bridging the gap between an abstract attack scenario derived from a specification and a penetration test on real implementations of a protocol is still an open issue. This work investigates an architecture for automatically generating abstract attacks and converting them to concrete tests on protocol implementations. In particular we aim to improve previously proposed blackbox testing methods in order to discover automatically new attacks and vulnerabilities. As a proof of concept we have experimented our proposed architecture to detect a renegotiation vulnerability on some implementations of SSL/TLS, a protocol widely used for securing electronic transactions.

  1. Spectrometric analog-to-digital converter

    International Nuclear Information System (INIS)

    Ormandzhiev, S.I.; Jordanov, V.T.

    1988-01-01

    Converter of digit-by-digit counterbalancing with slipping dial with number of channels equal to total number of states of the main digital-to-analog converter of digit-by-digit counterbalancing systems is presented. Algorithm for selection of digital-to-analog converters, which must be used by means of computer is suggested

  2. A novel series-resonant converter topology

    NARCIS (Netherlands)

    Tilgenkamp, N.V.; Haan, de S.W.H.; Huisman, H.

    1987-01-01

    A converter topology based on the principles of seriesresonant (SR) power conversion is described in which the input and output of this converter have one terminal in common, and the transformer is omitted. Both the underlying theory and associated waveforms are presented. The converter is suitable

  3. An innovative telemedicine knowledge translation program to improve quality of care in intensive care units: protocol for a cluster randomized pragmatic trial

    Directory of Open Access Journals (Sweden)

    Pinto Ruxandra

    2009-02-01

    Full Text Available Abstract Background There are challenges to timely adoption of, and ongoing adherence to, evidence-based practices known to improve patient care in the intensive care unit (ICU. Quality improvement initiatives using a collaborative network approach may increase the use of such practices. Our objective is to evaluate the effectiveness of a novel knowledge translation program for increasing the proportion of patients who appropriately receive the following six evidence-based care practices: venous thromboembolism prophylaxis; ventilator-associated pneumonia prevention; spontaneous breathing trials; catheter-related bloodstream infection prevention; decubitus ulcer prevention; and early enteral nutrition. Methods and design We will conduct a pragmatic cluster randomized active control trial in 15 community ICUs and one academic ICU in Ontario, Canada. The intervention is a multifaceted videoconferenced educational and problem-solving forum to organize knowledge translation strategies, including comparative audit and feedback, educational sessions from content experts, and dissemination of algorithms. Fifteen individual ICUs (clusters will be randomized to receive quality improvement interventions targeting one of the best practices during each of six study phases. Each phase lasts four months during the first study year and three months during the second. At the end of each study phase, ICUs are assigned to an intervention for a best practice not yet received according to a random schedule. The primary analysis will use patient-level process-of-care data to measure the intervention's effect on rates of adoption and adherence of each best practice in the targeted ICU clusters versus controls. Discussion This study design evaluates a new system for knowledge translation and quality improvement across six common ICU problems. All participating ICUs receive quality improvement initiatives during every study phase, improving buy-in. This study design

  4. Reduction of self-perceived discomforts in critically ill patients in French intensive care units: study protocol for a cluster-randomized controlled trial.

    Science.gov (United States)

    Kalfon, Pierre; Mimoz, Olivier; Loundou, Anderson; Geantot, Marie-Agnès; Revel, Nathalie; Villard, Isabelle; Amour, Julien; Azoulay, Elie; Garrouste-Orgeas, Maïté; Martin, Claude; Sharshar, Tarek; Baumstarck, Karine; Auquier, Pascal

    2016-02-16

    It is now well documented that critically ill patients are exposed to stressful conditions and experience discomforts from multiple sources. Improved identification of the discomforts of patients in intensive care units (ICUs) may have implications for managing their care, including consideration of ethical issues, and may assist clinicians in choosing the most appropriate interventions. The primary objective of this study was to assess the effectiveness of a multicomponent program of discomfort reduction in critically ill patients. The secondary objectives were to assess the sustainability of the impact of the program and the potential seasonality effect. We conducted a multicenter, cluster-randomized, controlled, single (patient)-blind study involving 34 French adult ICUs. The experimental intervention was a 6-month period during which the multicomponent program was implemented in the ICU and included the following steps: identification of discomforts, immediate feedback to the healthcare team, and implementation of targeted interventions. The control intervention was a 6-month period during which any program was implemented. The primary endpoint was the monthly overall score of self-reported discomfort from the French questionnaire on discomforts in ICU patients (IPREA). The secondary endpoints were the scores of the discomfort items of IPREA. The sample size was 660 individuals to obtain 80% power to detect a 25% difference in the overall discomfort score of IPREA between the two groups (design effect: 2.9). The results of this cluster-randomized controlled study are expected to confirm that a multicomponent program of discomfort reduction may be a new strategy in the management of care for critically ill patients. ClinicalTrials.gov NCT02442934, registered 11 May 2015.

  5. New 5 Kilowatt Free-Piston Stirling Space Converter Developments

    Science.gov (United States)

    Brandhorst, Henry W.

    2007-01-01

    NASA has recently funded development of a 5 kW (or greater) free-piston Stirling conversion system for reactor power systems. A nominal 5 kW converter allows two of these units to be dynamically balanced. A group of three dual-convertor combinations would yield the desired 30 kW. The status of this program will be presented. Goals include a specific power in excess of 140 W/kg at the converter level, lifetime in excess of five years and AC output. The initial step is the design and development of a nominal 5 kW per cylinder Stirling converter assembly (SCA) which will serve as a prototype of one or more SCAs that will make up the final 30 kW Stirling Converter Power System. Assumed requirements for this new converter for lunar fission power systems will be presented. The primary objective of this development effort will be to demonstrate a 5 kW SCA that can be tested to validate the viability of Stirling technology for space fission surface power systems.

  6. Nonlinear Passive Control of a Wave Energy Converter Subject to Constraints in Irregular Waves

    Directory of Open Access Journals (Sweden)

    Liguo Wang

    2015-06-01

    Full Text Available This paper investigates a passive control method of a point absorbing wave energy converter by considering the displacement and velocity constraints under irregular waves in the time domain. A linear generator is used as a power take-off unit, and the equivalent damping force is optimized to improve the power production of the wave energy converter. The results from nonlinear and linear passive control methods are compared, and indicate that the nonlinear passive control method leads to the excitation force in phase with the velocity of the converter that can significantly improve the energy production of the converter.

  7. Molten-salt converter reactors

    International Nuclear Information System (INIS)

    Perry, A.M.

    1975-01-01

    Molten-salt reactors appear to have substantial promise as advanced converters. Conversion ratios of 0.85 to 0.9 should be attainable with favourable fuel cycle costs, with 235 U valued at $12/g. An increase in 235 U value by a factor of two or three ($10 to $30/lb. U 3 O 8 , $75/SWU) would be expected to increase the optimum conversion ratio, but this has not been analyzed in detail. The processing necessary to recover uranium from the fuel salt has been partially demonstrated in the MSRE. The equipment for doing this would be located at the reactor, and there would be no reliance on an established recycle industry. Processing costs are expected to be quite low, and fuel cycle optimization depends primarily on inventory and burnup or replacement costs for the fuel and for the carrier salt. Significant development problems remain to be resolved for molten-salt reactors, notably the control of tritium and the elimination of intergranular cracking of Hastelloy-N in contact with tellurium. However, these problems appear to be amenable to solution. It is appropriate to consider separating the development schedule for molten-salt reactors from that for the processing technology required for breeding. The Molten-Salt Converter Reactor should be a useful reactor in its own right and would be an advance towards the achievement of true breeding in thermal reactors. (author)

  8. Hybrid thermionic-photovoltaic converter

    Energy Technology Data Exchange (ETDEWEB)

    Datas, A. [Instituto de Energía Solar, Universidad Politécnica de Madrid, 28040 Madrid (Spain)

    2016-04-04

    A conceptual device for the direct conversion of heat into electricity is presented. This concept hybridizes thermionic (TI) and thermophotovoltaic (TPV) energy conversion in a single thermionic-photovoltaic (TIPV) solid-state device. This device transforms into electricity both the electron and photon fluxes emitted by an incandescent surface. This letter presents an idealized analysis of this device in order to determine its theoretical potential. According to this analysis, the key advantage of this converter, with respect to either TPV or TI, is the higher power density in an extended temperature range. For low temperatures, TIPV performs like TPV due to the negligible electron flux. On the contrary, for high temperatures, TIPV performs like TI due to the great enhancement of the electron flux, which overshadows the photon flux contribution. At the intermediate temperatures, ∼1650 K in the case of this particular study, I show that the power density potential of TIPV converter is twice as great as that of TPV and TI. The greatest impact concerns applications in which the temperature varies in a relatively wide range, for which averaged power density enhancement above 500% is attainable.

  9. NPS Transit System Passenger Boardings Study: Converting Ticket Sales to Passenger Boardings.

    Science.gov (United States)

    2016-01-01

    This report examines the reporting of passenger boardings (unlinked passenger trips) by NPS transit systems that use a ticket sales conversion methodology. By studying and validating the park units' passenger boarding methodology from converting tick...

  10. Modular Power Converters for PV Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ozpineci, Burak [ORNL; Tolbert, Leon M [ORNL

    2012-05-01

    This report describes technical opportunities to serve as parts of a technological roadmap for Shoals Technologies Group in power electronics for PV applications. There are many different power converter circuits that can be used for solar inverter applications. The present applications do not take advantage of the potential for using common modules. We envision that the development of a power electronics module could enable higher reliability by being durable and flexible. Modules would have fault current limiting features and detection circuits such that they can limit the current through the module from external faults and can identify and isolate internal faults such that the remaining modules can continue to operate with only minimal disturbance to the utility or customer. Development of a reliable, efficient, low-cost, power electronics module will be a key enabling technology for harnessing more power from solar panels and enable plug and play operation. Power electronics for computer power supplies, communication equipment, and transportation have all targeted reliability and modularity as key requirements and have begun concerted efforts to replace monolithic components with collections of common smart modules. This is happening on several levels including (1) device level with intelligent control, (2) functional module level, and (3) system module. This same effort is needed in power electronics for solar applications. Development of modular units will result in standard power electronic converters that will have a lower installed and operating cost for the overall system. These units will lead to increased adaptability and flexibility of solar inverters. Incorporating autonomous fault current limiting and reconfiguration capabilities into the modules and having redundant modules will lead to a durable converter that can withstand the rigors of solar power generation for more than 30 years. Our vision for the technology roadmap is that there is no need

  11. Valuing Convertible Bonds Based on LSRQM Method

    Directory of Open Access Journals (Sweden)

    Jian Liu

    2014-01-01

    Full Text Available Convertible bonds are one of the essential financial products for corporate finance, while the pricing theory is the key problem to the theoretical research of convertible bonds. This paper demonstrates how to price convertible bonds with call and put provisions using Least-Squares Randomized Quasi-Monte Carlo (LSRQM method. We consider the financial market with stochastic interest rates and credit risk and present a detailed description on calculating steps of convertible bonds value. The empirical results show that the model fits well the market prices of convertible bonds in China’s market and the LSRQM method is effective.

  12. Series resonant converter with auxiliary winding turns: analysis, design and implementation

    Science.gov (United States)

    Lin, Bor-Ren

    2018-05-01

    Conventional series resonant converters have researched and applied for high-efficiency power units due to the benefit of its low switching losses. The main problems of series resonant converters are wide frequency variation and high circulating current. Thus, resonant converter is limited at narrow input voltage range and large input capacitor is normally adopted in commercial power units to provide the minimum hold-up time requirement when AC power is off. To overcome these problems, the resonant converter with auxiliary secondary windings are presented in this paper to achieve high voltage gain at low input voltage case such as hold-up time duration when utility power is off. Since the high voltage gain is used at low input voltage cased, the frequency variation of the proposed converter compared to the conventional resonant converter is reduced. Compared to conventional resonant converter, the hold-up time in the proposed converter is more than 40ms. The larger magnetising inductance of transformer is used to reduce the circulating current losses. Finally, a laboratory prototype is constructed and experiments are provided to verify the converter performance.

  13. Turf Conversion Measurement and Verification Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Stoughton, Kate M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Figueroa, Jorge [Western Resource Advocates, Boulder, CO (United States)

    2017-12-05

    This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings as a result of water conservation measures (WCMs) in energy performance contracts associated with converting turfgrass or other water-intensive plantings to water-wise and sustainable landscapes. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

  14. Converting pest insects into food

    DEFF Research Database (Denmark)

    Offenberg, Hans Joachim; Wiwatwittaya, Decha

    2010-01-01

    Canopy dwelling weaver ants (Oecophylla spp.) are used to control a variety of pests in a number of tropical tree crops. What is less familiar is the existence of commercial markets where these ants and their brood are sold for (i) human consumption, (ii) pet food or (iii) traditional medicine...... on management, 32-115 kg ant brood (mainly new queens) was harvested per ha per year without detrimental effect on colony survival and worker ant densities. This suggest that ant biocontrol and ant harvest can be sustainable integrated in plantations and double benefits derived. As ant production is fuelled...... by pest insects, problematic pests are converted into food and additional earnings. To assess the profitability of providing additional food for the ants, O. smaragdina food conversion efficiency (ECI) was estimated in the laboratory. This estimate suggests the feeding of weaver ants in ant farms...

  15. Efficiency of Capacitively Loaded Converters

    DEFF Research Database (Denmark)

    Andersen, Thomas; Huang, Lina; Andersen, Michael A. E.

    2012-01-01

    This paper explores the characteristic of capacitance versus voltage for dielectric electro active polymer (DEAP) actuator, 2kV polypropylene film capacitor as well as 3kV X7R multi layer ceramic capacitor (MLCC) at the beginning. An energy efficiency for capacitively loaded converters...... is introduced as a definition of efficiency. The calculated and measured efficiency curves for charging DEAP actuator, polypropylene film capacitor and X7R MLCC are provided and compared. The attention has to be paid for the voltage dependent capacitive load, like X7R MLCC, when evaluating the charging...... polypropylene film capacitor can be the equivalent capacitive load. Because of the voltage dependent characteristic, X7R MLCC cannot be used to replace the DEAP actuator. However, this type of capacitor can be used to substitute the capacitive actuator with voltage dependent property at the development phase....

  16. Grid Converters for Stationary Battery Energy Storage Systems

    DEFF Research Database (Denmark)

    Trintis, Ionut

    The integration of renewable energy sources in the power system, with high percentage, is a well known challenge nowadays. Power sources like wind and solar are highly volatile, with uctuations on various time scales. One long term solution is to build a continentwide or worldwide supergrid....... Another solution is to use distributed energy storage units, and create virtual power plants. Stationary energy storage is a complementary solution, which can postpone the network expansion and can be optimized for dierent kind of grid services. As an energy storage solution with timing for few seconds...... multilevel converter structure with integrated energy storage is introduced. This converter structure is suitable to interface low and medium voltage energy storage units to medium and high voltage grids. It can also interconnect a DC and AC grid with bidirectional power ow, were both can be backed...

  17. DC-to-DC converter comprising a reconfigurable capacitor unit

    NARCIS (Netherlands)

    2008-01-01

    The present invention relates to a configurable trench multi-capacitor device comprising a trench in a semiconductor substrate. The trench has a lateral extension exceeding 10 micrometer and a trench filling includes a number of at least four electrically conductive capacitor-electrode layers. A

  18. DC-to-DC converter comprising a reconfigurable capacitor unit

    NARCIS (Netherlands)

    Klootwijk, J.H.; Bergveld, H.J.; Roozeboom, F.; Reefman, D.; Ruigrok, J.

    2013-01-01

    The present invention relates to a configurable trench multi-capacitor device comprising a trench in a semiconductor substrate. The trench has a lateral extension exceeding 10 micrometer and a trench filling includes a number of at least four electrically conductive capacitor-electrode layers. A

  19. Test and evaluation of load converter topologies used in the Space Station Freedom power management and distribution dc test bed

    Science.gov (United States)

    Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.

    1991-01-01

    Power components hardware in support of the Space Station freedom dc Electric Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switch-mode converter, and a switching full-bridge forward converter. The topology, operation principles, and test results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

  20. Methods for CT automatic exposure control protocol translation between scanner platforms.

    Science.gov (United States)

    McKenney, Sarah E; Seibert, J Anthony; Lamba, Ramit; Boone, John M

    2014-03-01

    An imaging facility with a diverse fleet of CT scanners faces considerable challenges when propagating CT protocols with consistent image quality and patient dose across scanner makes and models. Although some protocol parameters can comfortably remain constant among scanners (eg, tube voltage, gantry rotation time), the automatic exposure control (AEC) parameter, which selects the overall mA level during tube current modulation, is difficult to match among scanners, especially from different CT manufacturers. Objective methods for converting tube current modulation protocols among CT scanners were developed. Three CT scanners were investigated, a GE LightSpeed 16 scanner, a GE VCT scanner, and a Siemens Definition AS+ scanner. Translation of the AEC parameters such as noise index and quality reference mAs across CT scanners was specifically investigated. A variable-diameter poly(methyl methacrylate) phantom was imaged on the 3 scanners using a range of AEC parameters for each scanner. The phantom consisted of 5 cylindrical sections with diameters of 13, 16, 20, 25, and 32 cm. The protocol translation scheme was based on matching either the volumetric CT dose index or image noise (in Hounsfield units) between two different CT scanners. A series of analytic fit functions, corresponding to different patient sizes (phantom diameters), were developed from the measured CT data. These functions relate the AEC metric of the reference scanner, the GE LightSpeed 16 in this case, to the AEC metric of a secondary scanner. When translating protocols between different models of CT scanners (from the GE LightSpeed 16 reference scanner to the GE VCT system), the translation functions were linear. However, a power-law function was necessary to convert the AEC functions of the GE LightSpeed 16 reference scanner to the Siemens Definition AS+ secondary scanner, because of differences in the AEC functionality designed by these two companies. Protocol translation on the basis of

  1. A Multi-Functional Power Electronic Converter in Distributed Generation Power Systems

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede; Pedersen, John Kim

    2005-01-01

    of the converter interfacing a wind power generation unit is also given. The power electronic interface performs the optimal operation in the wind turbine system to extract the maximum wind power, while it also plays a key role in a hybrid compensation system that consists of the active power electronic converter......This paper presents a power electronic converter which is used as an interface for a distributed generation unit/energy storage device, and also functioned as an active power compensator in a hybrid compensation system. The operation and control of the converter have been described. An example...... and passive filters connected to each distorting load or distributed generation (DG) unit. The passive filters are distributely located to remove major harmonics and provide reactive power compensation. The active power electronic filter corrects the system unbalance, removes the remaining harmonic components...

  2. Circular waveguide mode converters at 140 GHz

    International Nuclear Information System (INIS)

    Trulsen, J.; Woskoboinikow, P.; Temkin, R.J.

    1986-01-01

    A unified derivation of the coupled mode equations for circular waveguide is presented. Also, approximate design criteria for TE/sub 0n/ to TE/sub 0n'/ axisymmetric, TE 01 to TE 11 wriggle, and TE 01 to TM 11 bend converters are reviewed. Numerically solving the coupled mode equations, an optimized set of mode converters has been designed for conversion of a 2 millimeter wave TE 03 mode into TE 11 . This set consists of axisymmetric TE 03 to TE 02 and TE 02 to TE 01 converters followed by a wriggle TE 01 to TE 11 converter. This mode converter set was fabricated and tested using a 3 kW, 137 GHz gyrotron. A TE 11 mode purity of better than 97% was achieved. The TE 01 to TE 11 wriggle converter was experimentally optimized for a measured conversion efficiency of better than 99% not including ohmic losses

  3. Ocean floor mounting of wave energy converters

    Science.gov (United States)

    Siegel, Stefan G

    2015-01-20

    A system for mounting a set of wave energy converters in the ocean includes a pole attached to a floor of an ocean and a slider mounted on the pole in a manner that permits the slider to move vertically along the pole and rotate about the pole. The wave energy converters can then be mounted on the slider to allow adjustment of the depth and orientation of the wave energy converters.

  4. Vacuum-insulated catalytic converter

    Science.gov (United States)

    Benson, David K.

    2001-01-01

    A catalytic converter has an inner canister that contains catalyst-coated substrates and an outer canister that encloses an annular, variable vacuum insulation chamber surrounding the inner canister. An annular tank containing phase-change material for heat storage and release is positioned in the variable vacuum insulation chamber a distance spaced part from the inner canister. A reversible hydrogen getter in the variable vacuum insulation chamber, preferably on a surface of the heat storage tank, releases hydrogen into the variable vacuum insulation chamber to conduct heat when the phase-change material is hot and absorbs the hydrogen to limit heat transfer to radiation when the phase-change material is cool. A porous zeolite trap in the inner canister absorbs and retains hydrocarbons from the exhaust gases when the catalyst-coated substrates and zeolite trap are cold and releases the hydrocarbons for reaction on the catalyst-coated substrate when the zeolite trap and catalyst-coated substrate get hot.

  5. Semi-automatic logarithmic converter of logs

    International Nuclear Information System (INIS)

    Gol'dman, Z.A.; Bondar's, V.V.

    1974-01-01

    Semi-automatic logarithmic converter of logging charts. An original semi-automatic converter was developed for use in converting BK resistance logging charts and the time interval, ΔT, of acoustic logs from a linear to a logarithmic scale with a specific ratio for subsequent combining of them with neutron-gamma logging charts in operative interpretation of logging materials by a normalization method. The converter can be used to increase productivity by giving curves different from those obtained in manual, pointwise processing. The equipment operates reliably and is simple in use. (author)

  6. Multilevel converters for 10 MW Wind Turbines

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2011-01-01

    Several promising multi-level converter configurations for 10 MW Wind Turbines both with direct drive and one-stage gear box drive using Permanent Magnet Synchronous Generator (PMSG) are proposed, designed and compared. Reliability is a crucial indicator for large scale wind power converters...... that the three-level and five-level H-bridge converter topologies both have potential to achieve improved thermal performances compared to the three-level Neutral-Point-Clamped converter topology in the wind power application....

  7. Commutation Processes in Multiresonant ZVS Bridge Converter

    Directory of Open Access Journals (Sweden)

    Miroslaw Luft

    2008-01-01

    Full Text Available The analysis of the multiresonant ZVS DC/DC bridge converter is presented. The control system of the converter is basedon the method of frequency control at the constant time of transistor turn-off with a phase shift. The operation of the circuit is givenand the operating range of the converter is defined where ZVS switching operation is assured. Control characteristics are given andthe converter’s efficiency is defined. The circuit’s operation is analysed on the basis of results of the converter simulation tests using Simplorer programme.

  8. Training program to prepare the U.S. DOE laboratories for the entry into force of the protocol additional to the agreement between the United States of America and the International Atomic Energy Agency for the application of safeguards in the United

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, Brian David [Los Alamos National Laboratory; Stevens, Rebecca C [Los Alamos National Laboratory; Uribe, Eva C [Los Alamos National Laboratory; Sandoval, M Analisa [Los Alamos National Laboratory; Valente, John N [Los Alamos National Laboratory; Valente, John U [BNL; Jo, Jae H [BNL; Sellen, Joana [U.S. DOE/NNSA; Wonder, Edward [QINETIQ-NORTH AMERICA

    2009-01-01

    In 2008, a joint team from Brookhaven National Laboratory (BNL) and Los Alamos National Laboratory (LANL) consisting of specialists in training IAEA inspectors in the use of complementary access activities formulated a training program to prepare the U.S DOE laboratories for the entry into force of the U.S. Additional Protocol. Since the U.S. Additional Protocol would allow for IAEA access to the DOE laboratories under the aegis of complementary access activities, the DOE laboratories would need to prepare for such visits. The goal of the training was to ensure that the DOE laboratories would successfully host an IAEA complementary access. In doing so, the labs must be able to provide the IAEA with the information that the IAEA would need to resolve its questions about the U.S. Declaration and declared activities at the lab, and also protect certain equities, as provided under the U.S. Additional Protocol Article 1.b and c. which set forth a 'National Security Exclusion.' This 'NSE' states that the AP provisions apply within the United States 'excluding only instances where its application would result in access by the Agency to activities with direct national security significance to the United States or to location or information associated with such activities.' These activities are referred to collectively as DNSS-direct national security significance. Furthermore, the U.S. has a specific right to employ managed access, without prejudice to the right under Article 1.b, in connection with activities of DNSS. The provisions in Articles 1.b and 1.c are unique to the U.S. AP, and are additional to the more general right, under Article 7, to use managed access to protect from disclosure proprietary and/or proliferation-sensitive information, and to meet safety and security requirements, that is incorporated directly from the Model Additional Protocol. The BNL-LANL team performed training at Lawrence Livermore National Laboratory, Idaho

  9. Training program to prepare the U.S. DOE laboratories for the entry into force of the protocol additional to the agreement between the United States of America and the International Atomic Energy Agency for the application of safeguards in the United

    International Nuclear Information System (INIS)

    Boyer, Brian David; Stevens, Rebecca C.; Uribe, Eva C.; Sandoval, M. Analisa; Valente, John N.; Valente, John U.; Jo, Jae H.; Sellen, Joana; Wonder, Edward

    2009-01-01

    In 2008, a joint team from Brookhaven National Laboratory (BNL) and Los Alamos National Laboratory (LANL) consisting of specialists in training IAEA inspectors in the use of complementary access activities formulated a training program to prepare the U.S DOE laboratories for the entry into force of the U.S. Additional Protocol. Since the U.S. Additional Protocol would allow for IAEA access to the DOE laboratories under the aegis of complementary access activities, the DOE laboratories would need to prepare for such visits. The goal of the training was to ensure that the DOE laboratories would successfully host an IAEA complementary access. In doing so, the labs must be able to provide the IAEA with the information that the IAEA would need to resolve its questions about the U.S. Declaration and declared activities at the lab, and also protect certain equities, as provided under the U.S. Additional Protocol Article 1.b and c. which set forth a 'National Security Exclusion.' This 'NSE' states that the AP provisions apply within the United States 'excluding only instances where its application would result in access by the Agency to activities with direct national security significance to the United States or to location or information associated with such activities.' These activities are referred to collectively as DNSS-direct national security significance. Furthermore, the U.S. has a specific right to employ managed access, without prejudice to the right under Article 1.b, in connection with activities of DNSS. The provisions in Articles 1.b and 1.c are unique to the U.S. AP, and are additional to the more general right, under Article 7, to use managed access to protect from disclosure proprietary and/or proliferation-sensitive information, and to meet safety and security requirements, that is incorporated directly from the Model Additional Protocol. The BNL-LANL team performed training at Lawrence Livermore National Laboratory, Idaho National Laboratory, and Oak

  10. QCA Gray Code Converter Circuits Using LTEx Methodology

    Science.gov (United States)

    Mukherjee, Chiradeep; Panda, Saradindu; Mukhopadhyay, Asish Kumar; Maji, Bansibadan

    2018-04-01

    The Quantum-dot Cellular Automata (QCA) is the prominent paradigm of nanotechnology considered to continue the computation at deep sub-micron regime. The QCA realizations of several multilevel circuit of arithmetic logic unit have been introduced in the recent years. However, as high fan-in Binary to Gray (B2G) and Gray to Binary (G2B) Converters exist in the processor based architecture, no attention has been paid towards the QCA instantiation of the Gray Code Converters which are anticipated to be used in 8-bit, 16-bit, 32-bit or even more bit addressable machines of Gray Code Addressing schemes. In this work the two-input Layered T module is presented to exploit the operation of an Exclusive-OR Gate (namely LTEx module) as an elemental block. The "defect-tolerant analysis" of the two-input LTEx module has been analyzed to establish the scalability and reproducibility of the LTEx module in the complex circuits. The novel formulations exploiting the operability of the LTEx module have been proposed to instantiate area-delay efficient B2G and G2B Converters which can be exclusively used in Gray Code Addressing schemes. Moreover this work formulates the QCA design metrics such as O-Cost, Effective area, Delay and Cost α for the n-bit converter layouts.

  11. Design of coolant distribution system (CDS) for ITER PF AC/DC converter

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Bin [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Song, Zhiquan, E-mail: zhquansong@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Fu, Peng; Xu, Xuesong; Li, Chuan [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Wang, Min; Dong, Lin [China International Nuclear Fusion Energy Program Execution Center, Beijing 100862 (China)

    2016-10-15

    Highlights: • System process and arrangement has been proposed to meet the multiple requirements from the converter system. • Thermal hydraulic analysis model has been developed to size and predict the system operation behavior. • Prototype test has been performed to validate the proposed design methodology. - Abstract: The Poloidal Field (PF) converter unit, playing an essential role in the plasma shape and position control in vertical and horizontal direction, which is an important part of ITER power supply system. As an important subsystem of the converter unit, the coolant distribution system has the function to distribute the cooling water from ITER component cooling water system (CCWS) to its main components at the required flow rate, pressure and temperature. This paper presents the thermal hydraulic design of coolant distribution system for the ITER PF converter unit. Different operational requirements of the PF converter unit regarding flow rate, temperature and pressure have been analyzed to design the system process and arrangement. A thermal-hydraulic analysis model has been built to size the system and predict the flow rate and temperature distribution of the system under the normal operation. Based on the system thermal-hydraulic analysis results, the system pressure profile has been plotted to evaluate the pressure behavior along each client flow path. A CDS prototype for the ITER PF converter has been constructed and some experiments have been performed on it. A good agreement of the flow distribution and temperature behavior between the simulated and test results validate the proposed design methodology.

  12. Step-Up DC-DC converters

    DEFF Research Database (Denmark)

    Forouzesh, Mojtaba; Siwakoti, Yam P.; Gorji, Saman A.

    2017-01-01

    on the general law and framework of the development of next-generation step-up dc-dc converters, this paper aims to comprehensively review and classify various step-up dc-dc converters based on their characteristics and voltage-boosting techniques. In addition, the advantages and disadvantages of these voltage...

  13. Present trends in HVDC converter station design

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson, Lennart; Asplund, Gunnar; Bjorklund, Hans; Flisberg, Gunnar [ABB Power Systems AB, Ludvika (Sweden)

    1994-12-31

    HVDC converter station technology has developed rapidly to satisfy increasing requirements during past 10 - 15 years, but there has not been any dramatic changes since thyristor valves were introduced in the mid 70s. This paper describes some recent and expected future developments, that will substantiality change and simplify future converter stations. (author) 4 refs., 7 figs.

  14. Luminescent converter of neodymium laser radiation

    International Nuclear Information System (INIS)

    Ryba-Romanowski, W.; Golab, S.

    1992-01-01

    The new luminescent converter of neodymium laser radiation has been worked out. Activated inorganic compounds of ytterbium and erbium ions has been used as luminescent agent. The multi-component inorganic glass containing tellurium oxide as well as boron, sodium, magnesium and zinc oxides has been applied as a converter matrix

  15. Time-Interleaved Analog to Digital Converters

    NARCIS (Netherlands)

    Louwsma, S.M.; van Tuijl, Adrianus Johannes Maria; Nauta, Bram

    2010-01-01

    This book describes the research carried out by our PhD student Simon Louwsma at the University of Twente, The Netherlands in the field of high-speed Analogto- Digital (AD) converters. AD converters are crucial circuits for modern systems where information is stored or processed in digital form. Due

  16. Switched-mode converters (one quadrant)

    CERN Document Server

    Barrade, P

    2006-01-01

    Switched-mode converters are DC/DC converters that supply DC loads with a regulated output voltage, and protection against overcurrents and short circuits. These converters are generally fed from an AC network via a transformer and a conventional diode rectifier. Switched-mode converters (one quadrant) are non-reversible converters that allow the feeding of a DC load with unipolar voltage and current. The switched-mode converters presented in this contribution are classified into two families. The first is dedicated to the basic topologies of DC/DC converters, generally used for low- to mid-power applications. As such structures enable only hard commutation processes, the main drawback of such topologies is high commutation losses. A typical multichannel evolution is presented that allows an interesting decrease in these losses. Deduced from this direct DC/DC converter, an evolution is also presented that allows the integration of a transformer into the buck and the buck–boost structure. This enables an int...

  17. Controller for a wave energy converter

    Science.gov (United States)

    Wilson, David G.; Bull, Diana L.; Robinett, III, Rush D.

    2015-09-22

    A wave energy converter (WEC) is described, the WEC including a power take off (PTO) that converts relative motion of bodies of the WEC into electrical energy. A controller controls operation of the PTO, causing the PTO to act as a motor to widen a wave frequency spectrum that is usable to generate electrical energy.

  18. Full range ZVS DC-DC converter

    International Nuclear Information System (INIS)

    Upadhyay, Rinki; Badapanda, M.K.; Hannurkar, P.R.

    2011-01-01

    A 500 V, 24 Amp DC-DC converter with digital signal processor (DSP) based control and protection has been designed, fabricated and tested. Its power circuit consists of IGBT based single phase inverter bridge, ferrite transformer and diode rectifier. All IGBTs in the inverter bridge are operated in zero voltage switching (ZVS) mode to minimize switching losses thereby increasing the efficiency of the converter significantly. The efficiency of this converter is measured to be greater than 97% at full load. In a conventional full bridge inverter, typically ZVS is achieved under full load condition while at light load ZVS is lost. An auxiliary LC circuit has been intentionally incorporated in this converter to achieve ZVS even at light loaded conditions. Detailed simulation of the converter circuit is carried out and crucial waveforms have been presented in this paper. Microchip make dsPIC30F2020 DSP is employed to provide phase shifted PWMs to IGBTs in the inverter bridge. All the crucial parameters are also monitored by this DSP and in case of any unfavorable conditions, the converter is tripped off. Suitable experiments were carried out in this DC-DC converter under different loaded conditions and a close match between the simulated and experimental results were obtained. Such DC-DC converters can be connected in series or parallel for the development of solid state modular power supplies for various applications. (author)

  19. Passive Resonant Bidirectional Converter with Galvanic Barrier

    Science.gov (United States)

    Rosenblad, Nathan S. (Inventor)

    2014-01-01

    A passive resonant bidirectional converter system that transports energy across a galvanic barrier includes a converter using at least first and second converter sections, each section including a pair of transfer terminals, a center tapped winding; a chopper circuit interconnected between the center tapped winding and one of the transfer terminals; an inductance feed winding interconnected between the other of the transfer terminals and the center tap and a resonant tank circuit including at least the inductance of the center tap winding and the parasitic capacitance of the chopper circuit for operating the converter section at resonance; the center tapped windings of the first and second converter sections being disposed on a first common winding core and the inductance feed windings of the first and second converter sections being disposed on a second common winding core for automatically synchronizing the resonant oscillation of the first and second converter sections and transferring energy between the converter sections until the voltage across the pairs of transfer terminals achieves the turns ratio of the center tapped windings.

  20. Modeling and Simulation of Matrix Converter

    DEFF Research Database (Denmark)

    Liu, Fu-rong; Klumpner, Christian; Blaabjerg, Frede

    2005-01-01

    This paper discusses the modeling and simulation of matrix converter. Two models of matrix converter are presented: one is based on indirect space vector modulation and the other is based on power balance equation. The basis of these two models is• given and the process on modeling is introduced...

  1. A novel power converter for photovoltaic applications

    Science.gov (United States)

    Yuvarajan, S.; Yu, Dachuan; Xu, Shanguang

    A simple and economical power conditioner to convert the power available from solar panels into 60 Hz ac voltage is described. The raw dc voltage from the solar panels is converted to a regulated dc voltage using a boost converter and a large capacitor and the dc output is then converted to 60 Hz ac using a bridge inverter. The ratio between the load current and the short-circuit current of a PV panel at maximum power point is nearly constant for different insolation (light) levels and this property is utilized in designing a simple maximum power point tracking (MPPT) controller. The controller includes a novel arrangement for sensing the short-circuit current without disturbing the operation of the PV panel and implementing MPPT. The switching losses in the inverter are reduced by using snubbers. The results obtained on an experimental converter are presented.

  2. Step-Up DC-DC converters

    DEFF Research Database (Denmark)

    Forouzesh, Mojtaba; Siwakoti, Yam P.; Gorji, Saman A.

    2017-01-01

    on the general law and framework of the development of next-generation step-up dc-dc converters, this paper aims to comprehensively review and classify various step-up dc-dc converters based on their characteristics and voltage-boosting techniques. In addition, the advantages and disadvantages of these voltage......DC-DC converters with voltage boost capability are widely used in a large number of power conversion applications, from fraction-of-volt to tens of thousands of volts at power levels from milliwatts to megawatts. The literature has reported on various voltage-boosting techniques, in which......-boosting techniques and associated converters are discussed in detail. Finally, broad applications of dc-dc converters are presented and summarized with comparative study of different voltage-boosting techniques....

  3. A review of Indirect Matrix Converter Topologies

    Directory of Open Access Journals (Sweden)

    Salem Rahmani

    2015-08-01

    Full Text Available Abstract—Matrix Converter (MC is a modern direct AC/AC electrical power converter without dc-link capacitor. MC is operated in four quadrant, assuring a control of the output voltage, amplitude and frequency. The matrix converter has recently attracted significant attention among researchers and it has become increasing attractive for applications of wind energy conversion, military power supplies, induction motor drives, etc. Recently, different MC topologies have been proposed and developed which have their own advantages and disadvantages. Matrix converter can be classified as direct and indirect structures. The direct one has been elaborated in previous work. In this paper the indirect MCs are reviewed. Different characteristics of the indirect MC topologies are mentioned to show the strengths and weaknesses of such converter topologies.

  4. Vertical Protocol Composition

    DEFF Research Database (Denmark)

    Groß, Thomas; Mödersheim, Sebastian Alexander

    2011-01-01

    The security of key exchange and secure channel protocols, such as TLS, has been studied intensively. However, only few works have considered what happens when the established keys are actually used—to run some protocol securely over the established “channel”. We call this a vertical protocol.......e., that the combination cannot introduce attacks that the individual protocols in isolation do not have. In this work, we prove a composability result in the symbolic model that allows for arbitrary vertical composition (including self-composition). It holds for protocols from any suite of channel and application...

  5. Analytical and computational modelling for wave energy systems: the example of oscillating wave surge converters

    Science.gov (United States)

    Dias, Frédéric; Renzi, Emiliano; Gallagher, Sarah; Sarkar, Dripta; Wei, Yanji; Abadie, Thomas; Cummins, Cathal; Rafiee, Ashkan

    2017-08-01

    The development of new wave energy converters has shed light on a number of unanswered questions in fluid mechanics, but has also identified a number of new issues of importance for their future deployment. The main concerns relevant to the practical use of wave energy converters are sustainability, survivability, and maintainability. Of course, it is also necessary to maximize the capture per unit area of the structure as well as to minimize the cost. In this review, we consider some of the questions related to the topics of sustainability, survivability, and maintenance access, with respect to sea conditions, for generic wave energy converters with an emphasis on the oscillating wave surge converter. New analytical models that have been developed are a topic of particular discussion. It is also shown how existing numerical models have been pushed to their limits to provide answers to open questions relating to the operation and characteristics of wave energy converters.

  6. Analytical and computational modelling for wave energy systems: the example of oscillating wave surge converters.

    Science.gov (United States)

    Dias, Frédéric; Renzi, Emiliano; Gallagher, Sarah; Sarkar, Dripta; Wei, Yanji; Abadie, Thomas; Cummins, Cathal; Rafiee, Ashkan

    2017-01-01

    The development of new wave energy converters has shed light on a number of unanswered questions in fluid mechanics, but has also identified a number of new issues of importance for their future deployment. The main concerns relevant to the practical use of wave energy converters are sustainability, survivability, and maintainability. Of course, it is also necessary to maximize the capture per unit area of the structure as well as to minimize the cost. In this review, we consider some of the questions related to the topics of sustainability, survivability, and maintenance access, with respect to sea conditions, for generic wave energy converters with an emphasis on the oscillating wave surge converter. New analytical models that have been developed are a topic of particular discussion. It is also shown how existing numerical models have been pushed to their limits to provide answers to open questions relating to the operation and characteristics of wave energy converters.

  7. Cascaded H-Bridge with Bidirectional Boost Converters for Energy Storage

    DEFF Research Database (Denmark)

    Trintis, Ionut; Munk-Nielsen, Stig; Teodorescu, Remus

    2011-01-01

    This paper presents the design and control of a cascaded H-bridge converter for energy storage with bidirectional boost converter as charge/discharge unit. The disadvantage of the second harmonic on the main energy storage unit as well as its voltage variation with the state of charge is solved...... by this structure. The independent phase grid control is proposed for this topology. This strategy is able to control the average dc-link voltage for each phase independently and to balance the cells capacitors voltages. The balance of the energy storage units is achieved by controlling independently each cell...

  8. Families of quantum fingerprinting protocols

    Science.gov (United States)

    Lovitz, Benjamin; Lütkenhaus, Norbert

    2018-03-01

    We introduce several families of quantum fingerprinting protocols to evaluate the equality function on two n -bit strings in the simultaneous message passing model. The original quantum fingerprinting protocol uses a tensor product of a small number of O (logn ) -qubit high-dimensional signals [H. Buhrman et al., Phys. Rev. Lett. 87, 167902 (2001), 10.1103/PhysRevLett.87.167902], whereas a recently proposed optical protocol uses a tensor product of O (n ) single-qubit signals, while maintaining the O (logn ) information leakage of the original protocol [J. M. Arazola and N. Lütkenhaus, Phys. Rev. A 89, 062305 (2014), 10.1103/PhysRevA.89.062305]. We find a family of protocols which interpolate between the original and optical protocols while maintaining the O (logn ) information leakage, thus demonstrating a tradeoff between the number of signals sent and the dimension of each signal. There has been interest in experimental realization of the recently proposed optical protocol using coherent states [F. Xu et al., Nat. Commun. 6, 8735 (2015), 10.1038/ncomms9735; J.-Y. Guan et al., Phys. Rev. Lett. 116, 240502 (2016), 10.1103/PhysRevLett.116.240502], but as the required number of laser pulses grows linearly with the input size n , eventual challenges for the long-time stability of experimental setups arise. We find a coherent state protocol which reduces the number of signals by a factor 1/2 while also reducing the information leakage. Our reduction makes use of a simple modulation scheme in optical phase space, and we find that more complex modulation schemes are not advantageous. Using a similar technique, we improve a recently proposed coherent state protocol for evaluating the Euclidean distance between two real unit vectors [N. Kumar et al., Phys. Rev. A 95, 032337 (2017), 10.1103/PhysRevA.95.032337] by reducing the number of signals by a factor 1/2 and also reducing the information leakage.

  9. Wireless power charging using point of load controlled high frequency power converters

    Science.gov (United States)

    Miller, John M.; Campbell, Steven L.; Chambon, Paul H.; Seiber, Larry E.; White, Clifford P.

    2015-10-13

    An apparatus for wirelessly charging a battery of an electric vehicle is provided with a point of load control. The apparatus includes a base unit for generating a direct current (DC) voltage. The base unit is regulated by a power level controller. One or more point of load converters can be connected to the base unit by a conductor, with each point of load converter comprising a control signal generator that transmits a signal to the power level controller. The output power level of the DC voltage provided by the base unit is controlled by power level controller such that the power level is sufficient to power all active load converters when commanded to do so by any of the active controllers, without generating excessive power that may be otherwise wasted.

  10. DC to DC power converters and methods of controlling the same

    Science.gov (United States)

    Steigerwald, Robert Louis; Elasser, Ahmed; Sabate, Juan Antonio; Todorovic, Maja Harfman; Agamy, Mohammed

    2012-12-11

    A power generation system configured to provide direct current (DC) power to a DC link is described. The system includes a first power generation unit configured to output DC power. The system also includes a first DC to DC converter comprising an input section and an output section. The output section of the first DC to DC converter is coupled in series with the first power generation unit. The first DC to DC converter is configured to process a first portion of the DC power output by the first power generation unit and to provide an unprocessed second portion of the DC power output of the first power generation unit to the output section.

  11. Electron curing for high speed paper, film and foil converting

    International Nuclear Information System (INIS)

    Nablo, S.V.; Tripp, E.P.

    1979-01-01

    The status of self-shielded, compact electron processors for flexible web converting applications is reviewed. The uses of these units for a variety of laminating applications are described, with emphasis on the application techniques appropriate for low weight, (1 to 2 gm/m 2 ) 100% convertible adhesives. Performance data for electron cured adhesives with polyester/polyethylene systems is presented and compared with conventional urethane systems. The unique surface features of electron cured gravure coatings applied and cured at high speed are discussed, with reference to both paper and film substrates. An important advantage of electron curing of buried adhesive layers is the process quality control permitted by this 'all-electric' system. The performance characteristics of curing atmosphere control (inerting) for coatings are reviewed. Industrial experience with these processors has shown that effective inerting of coated flexible webs at speeds to 250 m/minute is both practical and economical. (author)

  12. Control of Modular Multilevel Converter with reduced internal data exchange

    DEFF Research Database (Denmark)

    Máthé, Lászlo; Burlacu, Paul Dan; Teodorescu, Remus

    2017-01-01

    for such an application, several key parameters have to be considered such as high speed data transfer with low propagation delay, data integrity, and ability for accurate synchronization. In order to minimize the data flow in the MMC a hierarchical control is proposed where a CCU calculates an identical reference......Modular Multilevel Converters (MMC) are penetrating due to their superior performances. Due to the modular structure of the converter, communication platform has to be established between the Sub-Modules (SM) and a Central Controller Unit (CCU). When the communication platform is designed...... for all the SMs while the modulation and capacitor voltage balancing is performed in the controller from the SM. Thus, at each sampling instance only four bytes references are sent by the central controller to the controllers from the SM, while one or two bytes are received from SMs. Further, the control...

  13. Electromagnetic Compatibility of Matrix Converter System

    Directory of Open Access Journals (Sweden)

    S. Fligl

    2006-12-01

    Full Text Available The presented paper deals with matrix converters pulse width modulation strategies design with emphasis on the electromagnetic compatibility. Matrix converters provide an all-silicon solution to the problem of converting AC power from one frequency to another, offering almost all the features required of an ideal static frequency changer. They possess many advantages compared to the conventional voltage or current source inverters. A matrix converter does not require energy storage components as a bulky capacitor or an inductance in the DC-link, and enables the bi-directional power flow between the power supply and load. The most of the contemporary modulation strategies are able to provide practically sinusoidal waveforms of the input and output currents with negligible low order harmonics, and to control the input displacement factor. The perspective of matrix converters regarding EMC in comparison with other types of converters is brightly evident because it is no need to use any equipment for power factor correction and current and voltage harmonics reduction. Such converter with proper control is properly compatible both with the supply mains and with the supplied load. A special digital control system was developed for the realized experimental test bed which makes it possible to achieve greater throughput of the digital control system and its variability.

  14. Underwater noise from a wave energy converter

    DEFF Research Database (Denmark)

    Tougaard, Jakob

    A recent addition to the anthropogenic sources of underwater noise is offshore wave energy converters. Underwater noise was recorded from the Wavestar wave energy converter located at Hastholm, Denmark (57°7.73´N, 8°37.23´E). The Wavestar is a full-scale test and demonstration converter...... in full operation and start and stop of the converter. Median broad band (10 Hz – 20 kHz) sound pressure level (Leq) was 123 dB re. 1 Pa, irrespective of status of the wave energy converter (stopped, running or starting/stopping). The most pronounced peak in the third-octave spectrum was in the 160 Hz...... significant noise above ambient could be detected above the 250 Hz band. The absolute increase in noise above ambient was very small. L50 third-octave levels in the four bands with the converter running were thus only 1-2 dB above ambient L50 levels. The noise recorded 25 m from the wave energy converter...

  15. Converting Hangar High Expansion Foam Systems to Prevent Cockpit Damage: Full-Scale Validation Tests

    Science.gov (United States)

    2017-09-01

    AFCEC-CO-TY-TR-2018-0001 CONVERTING HANGAR HIGH EXPANSION FOAM SYSTEMS TO PREVENT COCKPIT DAMAGE: FULL-SCALE VALIDATION TESTS Gerard G...manufacturer, or otherwise does not constitute or imply its endorsement, recommendation , or approval by the United States Air Force. The views and...09-2017 Final Test Report May 2017 Converting Hangar High Expansion Foam Systems to Prevent Cockpit Damage: Full-Scale Validation Tests N00173-15-D

  16. On The Snubber Influence To The Switching And Conduction Losses In A Converter Using Switched Capacitor

    Directory of Open Access Journals (Sweden)

    Viorel DUGAN

    2002-12-01

    Full Text Available The paper deals to design and to compute the snubber parameters influence on the switching and conduction losses of the transistors (IGBT used as bidirectional switches in a converter with switched capacitor. The converter was modelled with difference equations, and the transistors during turn-on and turn-off processes were simulated by dynamically varying resistance models. The energy loss per switching, commutation time, the variation of the transistor voltage etc. and the influence of snubber parameters in each of these cases are shown in the context of a converter used as a 50Hz reactive power controller unit

  17. CAS - CERN Accelerator School: Power Converters

    CERN Document Server

    2015-01-01

    These proceedings collate lectures given at the twenty-eighth specialized course organised by the CERN Accelerator School (CAS). The course was held at the Hotel du Parc, Baden, Switzerland from 7 - 14 May 2014, in collaboration with the Paul Scherrer Institute. Following introductory lectures on accelerators and the requirements on power converters, the course covered components and topologies of the different types of power converters needed for particle accelerators. Issues of design, control and exploitation in a sometimes-hostile environment were addressed. Site visits to ABB and PSI provided an insight into state-of-the-art power converter production and operation, while topical seminars completed the programme.

  18. High-power converters and AC drives

    CERN Document Server

    Wu, Bin

    2017-01-01

    This new edition reflects the recent technological advancements in the MV drive industry, such as advanced multilevel converters and drive configurations. It includes three new chapters, Control of Synchronous Motor Drives, Transformerless MV Drives, and Matrix Converter Fed Drives. In addition, there are extensively revised chapters on Multilevel Voltage Source Inverters and Voltage Source Inverter-Fed Drives. This book includes a systematic analysis on a variety of high-power multilevel converters, illustrates important concepts with simulations and experiments, introduces various megawatt drives produced by world leading drive manufacturers, and addresses practical problems and their mitigations methods.

  19. Field Data Logger Prototype for Power Converters

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Ghimire, Pramod; Thøgersen, Paul Bach

    2014-01-01

    and subsequent analysis of the data. This paper presents the development of a low cost prototype field data logger prototype using Raspberry PI and industrial sensors. The functionalities of the data logger prototype are described. An online rainflow count algorithm has been implemented as well.......Mission profile data is very important for the cost effective and reliable design of power converters. The converter design can be improved on the basis of actual field data. Actual mission profile data can be collected for the power converters using field data loggers over a long period of time...

  20. Synchronous Control of Modular Multilevel Converters

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede; Bose, Bimal K.

    2002-01-01

    A novel method of direct synchronous pulsewidth modulation (PWM) is applied for control of modular multilevel converters consisting from three standard triphase inverter modules along with an 0.33 p.u. output transformer. The proposed method provides synchronisation of the voltage waveforms...... for each module and the composed voltage at the output of the converter. Multilevel output voltage of the converter has quarter-wave symmetry during the whole range including the zone of overmodulation. Both continuous and discontinuous versions of synchronous PWM, based on vector approach...

  1. Implementation of the Kyoto protocol

    International Nuclear Information System (INIS)

    2006-07-01

    The Rio Earth summit in 1992 has been the starting point of an international awareness about the global risk of climatic change. At this occasion, the richest countries committed themselves to stabilize their greenhouse gas emissions and to reach by the year 2000 an emissions level equivalent to the one of 1990. The Kyoto protocol in 1997 has permitted to convert this will into juridically constraining quantitative commitments. In 2005, Russia ratified the protocol while in 2001 the USA refused to do so. Because the commitments signed are ambitious, flexibility mechanisms have been implemented: 'emission permits' (emissions trading), 'joint implementation' allowing the investments abroad for greenhouse gases abatement in another developed country, and 'clean development mechanisms' when investments are made in a developing country. The Marrakech conference of December 2001 has permitted to fix up the eligibility criteria of projects belonging to the joint implementation and clean development mechanisms. The effective implementation of these mechanisms still raises technical difficulties to evaluate and measure the effective abatement of greenhouse gas emissions. (J.S.)

  2. Design and implementation of a bidirectional current-controlled voltage-regulated DC-DC switched-mode converter

    CSIR Research Space (South Africa)

    Coetzer, A

    2016-01-01

    Full Text Available The design and implementation of a bidirectional current-controlled voltage-regulated DC-DC converter is presented. The converter is required to connect a battery of electrochemical cells (the battery) to an asynchronous motor-drive unit via a...

  3. Discussion on the control method of the inductor-converter bridge by simulation and experiment

    International Nuclear Information System (INIS)

    Hirano, M.; Kustom, R.L.

    1983-07-01

    With the development of the superconducting magnet as an energy storage unit, pulsed power loads between superconducting magnets of increasing magnitude up to several hundred megawatts or more appear within the realm of possibility. An energy storage unit that is independent of the power grid can be used in applications where the pulsed power required from the power grid may cause a hazardous effect on the power system. An energy transfer system between the storage and the load units eliminates the disturbance on the power grid. An inductor-converter bridge is proposed for such a purpose. The inductor-converter bridge (ICB) is a solid state DC-AC-DC converter system for reversible energy transfer between two high-inductance inductors. The converter thyristors are naturally commutated by a set of wye-connected capacitors on the AC lines of the circuit. The circuit is designed so that, in every converter cycle, a very small fraction of the magnet energy is stored in these capacitors. The characteristics of the inductor-converter bridge are briefly summarized as follows: low energy loss, reversibility of the energy transfer direction, controllability of the energy transfer rate, and no conversion to another energy form

  4. Study protocol to assess the effectiveness and safety of a flexible family visitation model for delirium prevention in adult intensive care units: a cluster-randomised, crossover trial (The ICU Visits Study).

    Science.gov (United States)

    Rosa, Regis Goulart; Falavigna, Maicon; Robinson, Caroline Cabral; da Silva, Daiana Barbosa; Kochhann, Renata; de Moura, Rafaela Moraes; Santos, Mariana Martins Siqueira; Sganzerla, Daniel; Giordani, Natalia Elis; Eugênio, Cláudia; Ribeiro, Tarissa; Cavalcanti, Alexandre Biasi; Bozza, Fernando; Azevedo, Luciano Cesar Pontes; Machado, Flávia Ribeiro; Salluh, Jorge Ibrain Figueira; Pellegrini, José Augusto Santos; Moraes, Rafael Barberena; Hochegger, Taís; Amaral, Alexandre; Teles, José Mario Meira; da Luz, Lucas Gobetti; Barbosa, Mirceli Goulart; Birriel, Daniella Cunha; Ferraz, Iris de Lima; Nobre, Vandack; Valentim, Helen Martins; Corrêa E Castro, Livia; Duarte, Péricles Almeida Delfino; Tregnago, Rogério; Barilli, Sofia Louise Santin; Brandão, Nilton; Giannini, Alberto; Teixeira, Cassiano

    2018-04-13

    Flexible intensive care unit (ICU) visiting hours have been proposed as a means to improve patient-centred and family-centred care. However, randomised trials evaluating the effects of flexible family visitation models (FFVMs) are scarce. This study aims to compare the effectiveness and safety of an FFVM versus a restrictive family visitation model (RFVM) on delirium prevention among ICU patients, as well as to analyse its potential effects on family members and ICU professionals. A cluster-randomised crossover trial involving adult ICU patients, family members and ICU professionals will be conducted. Forty medical-surgical Brazilian ICUs with RFVMs (<4.5 hours/day) will be randomly assigned to either an RFVM (visits according to local policies) or an FFVM (visitation during 12 consecutive hours per day) group at a 1:1 ratio. After enrolment and follow-up of 25 patients, each ICU will be switched over to the other visitation model, until 25 more patients per site are enrolled and followed. The primary outcome will be the cumulative incidence of delirium among ICU patients, measured twice a day using the Confusion Assessment Method for the ICU. Secondary outcome measures will include daily hazard of delirium, ventilator-free days, any ICU-acquired infections, ICU length of stay and hospital mortality among the patients; symptoms of anxiety and depression and satisfaction among the family members; and prevalence of burnout symptoms among the ICU professionals. Tertiary outcomes will include need for antipsychotic agents and/or mechanical restraints, coma-free days, unplanned loss of invasive devices and ICU-acquired pneumonia, urinary tract infection or bloodstream infection among the patients; self-perception of involvement in patient care among the family members; and satisfaction among the ICU professionals. The study protocol has been approved by the research ethics committee of all participant institutions. We aim to disseminate the findings through

  5. The French dosimetry protocol

    International Nuclear Information System (INIS)

    Dutreix, A.

    1985-01-01

    After a general introduction the protocol is divided in five sections dealing with: determination of the quality of X-ray, γ-ray and electron beams; the measuring instrument; calibration of the reference instrument; determination of the reference absorbed dose in the user's beams; determination of the absorbed dose in water at other points, in other conditions. The French protocol is not essentially different from the Nordic protocol and it is based on the experience gained in using both the American and the Nordic protocols. Therefore, only the main difference with the published protocols are discussed. (Auth.)

  6. Ocean Wave Energy: Underwater Substation System for Wave Energy Converters

    International Nuclear Information System (INIS)

    Rahm, Magnus

    2010-01-01

    This thesis deals with a system for operation of directly driven offshore wave energy converters. The work that has been carried out includes laboratory testing of a permanent magnet linear generator, wave energy converter mechanical design and offshore testing, and finally design, implementation, and offshore testing of an underwater collector substation. Long-term testing of a single point absorber, which was installed in March 2006, has been performed in real ocean waves in linear and in non-linear damping mode. The two different damping modes were realized by, first, a resistive load, and second, a rectifier with voltage smoothing capacitors and a resistive load in the DC-link. The loads are placed on land about 2 km east of the Lysekil wave energy research site, where the offshore experiments have been conducted. In the spring of 2009, another two wave energy converter prototypes were installed. Records of array operation were taken with two and three devices in the array. With two units, non-linear damping was used, and with three units, linear damping was employed. The point absorbers in the array are connected to the underwater substation, which is based on a 3 m3 pressure vessel standing on the seabed. In the substation, rectification of the frequency and amplitude modulated voltages from the linear generators is made. The DC voltage is smoothened by capacitors and inverted to 50 Hz electrical frequency, transformed and finally transmitted to the on-shore measuring station. Results show that the absorption is heavily dependent on the damping. It has also been shown that by increasing the damping, the standard deviation of electrical power can be reduced. The standard deviation of electrical power is reduced by array operation compared to single unit operation. Ongoing and future work include the construction and installation of a second underwater substation, which will connect the first substation and seven new WECs

  7. A three-port direct current converter

    DEFF Research Database (Denmark)

    2016-01-01

    circuit comprises a connection between the at least one input direct current source and the at least one storage battery, the primary side circuit configured for operating as a buck converter; a second magnetic component serially coupled to the first single magnetic component, wherein the first and second...... magnetic components are configured to perform a voltage step-up, wherein the secondary side circuit comprises a connection between the at least one storage battery and at least one load, the secondary side configured for operating as a tapped boost converter; wherein the three-port direct current converter......The three-port direct current converter comprising: at least one input direct current source; at least one storage battery; a primary side circuit; a secondary side circuit; a first single magnetic component shared by the primary side circuit and the secondary side circuit, wherein the primary side...

  8. State estimation for wave energy converters

    Energy Technology Data Exchange (ETDEWEB)

    Bacelli, Giorgio; Coe, Ryan Geoffrey

    2017-04-01

    This report gives a brief discussion and examples on the topic of state estimation for wave energy converters (WECs). These methods are intended for use to enable real-time closed loop control of WECs.

  9. Input-output rearrangement of isolated converters

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre; Kovacevic, Milovan; Mønster, Jakob Døllner

    2015-01-01

    This paper presents a new way of rearranging the input and output of isolated converters. The new arrangement posses several advantages, as increased voltage range, higher power handling capabilities, reduced voltage stress and improved efficiency, for applications where galvanic isolation...

  10. Test and Analysis of Metallurgical Converter Equipment

    Directory of Open Access Journals (Sweden)

    Shan Pang

    2013-05-01

    Full Text Available Oxygen top-blow converter is the main equipment in steel making, and its work reliability decides the security and economy of steel production. Therefore, how to design and test analysis of convertor has been an important subject of industry research. Geometric modelling and structure analysis of converter tilting device by using Pro/E program .The design Principle, basic design structure were analyzed in detail. The computer simulation software of metallurgical converter equipment and how to use it were introduced .It developed by VC++ software. The position of barycentre and moment curve in No.3 and No.4 are calculated. The converter acceleration down dip can be resolved by comparing the moment curve and center curve.

  11. Reliability of power electronic converter systems

    CERN Document Server

    Chung, Henry Shu-hung; Blaabjerg, Frede; Pecht, Michael

    2016-01-01

    This book outlines current research into the scientific modeling, experimentation, and remedial measures for advancing the reliability, availability, system robustness, and maintainability of Power Electronic Converter Systems (PECS) at different levels of complexity.

  12. Monitoring of high voltage supply using the Controller Area Network protocol

    Energy Technology Data Exchange (ETDEWEB)

    Luz, Igo Amauri dos S.; Farias, Paulo Cesar M.A.; Guedes, Germano P. [Universidade Estadual de Feira de Santana (UEFS), BA (Brazil)

    2011-07-01

    Full text: In recent years, experimental physics has made great progress in the investigation of the phenomenology of neutrinos, with significant contribution from experiments using nuclear reactors as source of particles. In this context, The Neutrinos Angra Project proposes the use of an anti-neutrinos detector with ability to monitor parameters related to the activity of nuclear reactors. One of the tasks defined in the project is the development of a system to control and to monitor the high voltage supply units used by the photomultiplier tubes (PMTs) of the detector. The solution proposed in this work is based on the use of microcontrollers, from Microchip PIC family to adjust the operating point of the high voltage supply units and to acquire the current and output voltage data. Analysis of these data allows the effective control of the gain of the PMTs and to identify anomalous operational conditions. In this work is proposed the study of the Controller Area Network (CAN) protocol and the implementation of a laboratory network to reproduce the typical operations of data acquisition and information transfer between the nodes. The development of this network is divided in two stages. The first part consisted of the setup of a CAN network, using the PIC18F2680 microcontroller, which has the CAN protocol internally implemented. This network serves as a reduced model of the final system, allowing simulation of typical situations of data acquisition and transmission between the nodes and a computer. In the second part of the work, the PIC18F4550 microcontroller was associated with the external CAN controller MCP2515 to develop a CAN/USB converter. This converter provides a new communication channel between network nodes and the computer, in addition to the RS232 interface. (author)

  13. Resonant Wave Energy Converters: Concept development

    International Nuclear Information System (INIS)

    Arena, Felice; Barbaro, Giuseppe; Fiamma, Vincenzo; Laface, Valentina; Malara, Giovanni; Romolo, Alessandra; Strati, Federica Mara

    2015-01-01

    The Resonant Wave Energy Converter (REWEC) is a device for converting sea wave energy to electrical energy. It belongs to the family of Oscillating Water Columns and is composed by an absorbing chamber connected to the open sea via a vertical duct. The paper gives a holistic view on the concept development of the device, starting from its implementation in the context of submerged breakwaters to the recently developed vertical breakwaters. [it

  14. AC – AC Converters for UPS

    Directory of Open Access Journals (Sweden)

    Rusalin Lucian R. Păun

    2008-05-01

    Full Text Available This paper propose a new control technique forsingle – phase AC – AC converters used for a on-line UPSwith a good dynamic response, a reduced-partscomponents, a good output characteristic, a good powerfactorcorrection(PFC. This converter no needs anisolation transformer. A power factor correction rectifierand an inverter with the proposed control scheme has beendesigned and simulated using Caspoc2007, validating theconcept.

  15. Switching power converters medium and high power

    CERN Document Server

    Neacsu, Dorin O

    2013-01-01

    An examination of all of the multidisciplinary aspects of medium- and high-power converter systems, including basic power electronics, digital control and hardware, sensors, analog preprocessing of signals, protection devices and fault management, and pulse-width-modulation (PWM) algorithms, Switching Power Converters: Medium and High Power, Second Edition discusses the actual use of industrial technology and its related subassemblies and components, covering facets of implementation otherwise overlooked by theoretical textbooks. The updated Second Edition contains many new figures, as well as

  16. The rotating converter GKN II starts operation

    International Nuclear Information System (INIS)

    Jergas, E.

    1989-01-01

    At the beginning of 1989 the energy supply and consumption of the 110-kV-railway mains has changed considerably with starting the rotating converter of the German Federal Railways (DB) in the joint nuclear power station Neckar GmbH (GKN) block II. A description is given of the planned utilization of the rotating converters at baseload operation and possibilities for optimal energy use are shown. (orig.) [de

  17. Fast simulation techniques for switching converters

    Science.gov (United States)

    King, Roger J.

    1987-01-01

    Techniques for simulating a switching converter are examined. The state equations for the equivalent circuits, which represent the switching converter, are presented and explained. The uses of the Newton-Raphson iteration, low ripple approximation, half-cycle symmetry, and discrete time equations to compute the interval durations are described. An example is presented in which these methods are illustrated by applying them to a parallel-loaded resonant inverter with three equivalent circuits for its continuous mode of operation.

  18. Resonance gamma-transducer with thin converter

    International Nuclear Information System (INIS)

    Mirzababaev, R.M.

    1993-01-01

    A resonance detector with stainless steel foil (∼3000 A) is more efficient than conventional detectors as regards the recording Rayleigh scattering of Moessbauer effect. If the scatterer contains resonance nuclei (iron), the detector simultaneously records in the same spectrum both Zeeman lines and the line resulted to Rayleigh quanta scattering on electrons. Zeeman lines are formed due to photoabsorption in the converter. The central line is associated with resonance absorption in the converter

  19. Protocol Implementation Generator

    DEFF Research Database (Denmark)

    Carvalho Quaresma, Jose Nuno; Probst, Christian W.

    2010-01-01

    Users expect communication systems to guarantee, amongst others, privacy and integrity of their data. These can be ensured by using well-established protocols; the best protocol, however, is useless if not all parties involved in a communication have a correct implementation of the protocol and a...... Generator framework based on the LySatool and a translator from the LySa language into C or Java....... necessary tools. In this paper, we present the Protocol Implementation Generator (PiG), a framework that can be used to add protocol generation to protocol negotiation, or to easily share and implement new protocols throughout a network. PiG enables the sharing, verification, and translation...

  20. [Comparision of in vitro maturation applied in PCOS and non-PCOS patients undergo stimulated and unstimulated protocols].

    Science.gov (United States)

    Wang, Peiyu; Zhao, Junzhao; Jin, Congcong; Yu, Rong; Lin, Jia; Zhu, Ruru; Wu, Yonggen

    2014-12-01

    To compare the laboratory and clinical results between unstimulated in vitro maturation (IVM) and IVM converted from in vitro fertilization (IVF) in polycystic ovarian syndrome (PCOS) and non-PCOS patients. We divided 591 IVM cycles in the First Affiliated Hospital of Wenzhou Medical Univesity from Jan. 2008 to Dec. 2013 into 4 groups: group A1B1, PCOS patients underwent unstimulated IVM protocol, 240 cycles; group A1B2, PCOS patients underwent IVM converted from conventional stimulated IVF protocol, 153 cycles; group A2B1, non-PCOS patients underwent unstimutlated IVM protocol, 103 cycles; group A2B2, non-PCOS patient underwent IVM converted from conventional stimulated IVF protocol, 95 cycles. Multiple linear regression method and binary logistic regression method were used to assess the influence of PCOS and protocols for IVM on laboratory and clinical outcomes. The mean number of oocytes retrieved was positively related with PCOS [partial regression coefficient (B) = 3.37, P PCOS and IVM converted from IVF (B = 0.08, P = 0.010; B = 0.09, P = 0.001), as well as implantation rate related with them (B = 0.07, P = 0.010; B = 0.10, P PCOS and IVM converted from IVF improved hCG positive (hCG>10 U/L) rate (OR = 1.636, 95%CI: 1.113-2.204, P PCOS condition and protocol used (P > 0.05). PCOS and IVM converted from IVF protocol improved the high-quality embryo rate, implantation rate, hCG positive rate and clinical pregnancy rate. IVM converted from IVF protocol reduced the spontaneous abortion rate. PCOS patients may be more suitable for the IVM treatment. No matter PCOS or non-PCOS patients, IVM converted from IVF protocol had better pregnancy outcome than that of unstimulated cycle.

  1. LHC Power Converters: A Precision Game

    CERN Multimedia

    2001-01-01

    The LHC test-bed, String 2, is close to commissioning and one important element to get a first chance to prove what it can do is the power converter system. In String 2 there are 16 converters, in the full LHC there will be almost 1800. This article takes a look at what is so special about the power converters for the LHC. The 13 000 Amps power converters with the watercooled cables going to the String 2 feedboxes. The LHC's superconducting magnets will be the pinnacle of high technology. But to work, they'll need the help of high-precision power converters to supply them with extremely stable DC current. Perfection will be the name of the game, with an accuracy of just 1-2 parts per million (ppm) required. LEP, for the sake of comparison, could live with 10-20 ppm. The LHC's power converters will be very different from those of LEP or the SPS since the new accelerator's magnets are mostly superconducting. That means that they require much higher currents at a lower voltage since superconductors have no re...

  2. Adaptive electrothermal protection of power converters

    Directory of Open Access Journals (Sweden)

    Baraniuk G. A.

    2017-06-01

    Full Text Available Thermal management for power converters during normal operation and transient modes when electrical components are warmed up is an actual problem. This can be particularly important for converters with intermittent duty operation, e.g. power supplies for resistance welding. According to some research, nearly 60% of failures are temperature-induced, and for every 10°C temperature rise in operating environment the failure rate nearly doubles. In this paper, thermal motion of state equations eigenvalue is analysed. It is shown, that in semiconductor converters with an output smoothing filter it is appropriate to use thermal protection devices based on thermal normalisation of the converter filter and, while for cases when short circuits are possible it is appropriate to use a soft start system with thermal adaptation for soft start time factor. Based on these results, two systems of thermal protections operating for semiconductor power converters are introduced. Simulation of combined electromagnetic and thermal processes in buck converter operating with both thermal management systems in overlapping environments MATLAB/Simulink and PLECS showed the possibility to significantly reduce thermal shock on semiconductor components. Using the system of filter parameters normalisation decreases the temperature of the crystal from 210°C to 85°C, using the adaptive soft start system decreases the temperature from 180°C to 80°C. The simulation results are confirmed by tests on real devices.

  3. Real life experimental determination of platinum group metals content in automotive catalytic converters

    Science.gov (United States)

    Yakoumis, I.; Moschovi, A. M.; Giannopoulou, I.; Panias, D.

    2018-03-01

    The real life experimental protocol for the preparation of spent automobile catalyst samples for elemental analysis is thoroughly described in the following study. Collection, sorting and dismantling, homogenization and sample preparation for X-Ray fluorescence spectroscopy and Atomic Adsorption Spectroscopy combined with Inductive coupled plasma mass spectrometry are discussed in detail for both ceramic and metallic spent catalysts. The concentrations of Platinum Group Metals (PGMs) in spent catalytic converters are presented based on typical consignments of recycled converters (more than 45,000 pieces) from the Greek Market. The conclusions clearly denoted commercial metallic catalytic foil contains higher PGMs loading than ceramic honeycombs. On the other hand, the total PGMs loading in spent ceramic catalytic converters has been found higher than the corresponding value for the metallic ones.

  4. Preliminary design of the ITER AC/DC converters supplied by the Korean Domestic Agency

    International Nuclear Information System (INIS)

    Oh, J.S.; Choi, J.; Suh, J.H.; Liu, H.; Hwang, K.; Chung, I.; Lee, S.; Kang, J.; Park, H.; Jung, W.; Jo, S.; Gweon, H.; Lee, Y.; Lee, W.; Kim, J.B.; Han, S.H.; Hong, G.D.; Lee, J.S.; Lee, B.W.; Yeo, C.H.

    2013-01-01

    Highlights: ► A self-supporting aluminium structure and symmetrical thyristor assembly are devised to assure a strong and reliable ITER converter. ► Converters are designed to be installable in a compact space with three times higher power density than normal industrial installations. ► Heating of the building structure due to high magnetic field by converters are identified and certain solutions are addressed in the building design. ► A cooperative fast control scheme is adopted to compensate fast reactive power change of up to the level of 900 Mvar. -- Abstract: The preliminary design for ITER AC/DC converters under the responsibility of the Korean Domestic Agency is performed on the basis of the engineering experience of previous R and D for a full-scale 6-pulse CS (Central Solenoid) converter unit. This paper describes key features of the preliminary design for the respective sub-systems; integrated self-supporting aluminium structure and symmetrical thyristor assembly for strong and reliable converters, optimised impedance of the converter transformer to limit short circuit current, coaxial-type AC bus bars to shield high magnetic field around wall penetrations, compact components to fit into given building space. The insulation and the minimisation of electrical loops of concrete rebar below the converter installations are essential to prevent floor heating. Required output voltage or current of converters is provided by a conventional controller. A master controller is designed to collect predicted reactive powers from each converter and deliver processed data to the reactive power compensation (RPC) system to improve the regulation speed of the RPC controller with fast feed-forward compensation under fast reactive power transients

  5. Preliminary design of the ITER AC/DC converters supplied by the Korean Domestic Agency

    Energy Technology Data Exchange (ETDEWEB)

    Oh, J.S., E-mail: jsoh@nfri.re.kr [ITER Korea, National Fusion Research Institute, Daejeon 305-806 (Korea, Republic of); Choi, J.; Suh, J.H. [ITER Korea, National Fusion Research Institute, Daejeon 305-806 (Korea, Republic of); Liu, H.; Hwang, K.; Chung, I.; Lee, S.; Kang, J.; Park, H.; Jung, W.; Jo, S.; Gweon, H.; Lee, Y.; Lee, W. [Dawonsys Corp., Siheung 429-450 (Korea, Republic of); Kim, J.B.; Han, S.H.; Hong, G.D.; Lee, J.S.; Lee, B.W.; Yeo, C.H. [Hyosung Corp., 450, Gongdeok-Dong, Seoul 121-720 (Korea, Republic of); and others

    2013-10-15

    Highlights: ► A self-supporting aluminium structure and symmetrical thyristor assembly are devised to assure a strong and reliable ITER converter. ► Converters are designed to be installable in a compact space with three times higher power density than normal industrial installations. ► Heating of the building structure due to high magnetic field by converters are identified and certain solutions are addressed in the building design. ► A cooperative fast control scheme is adopted to compensate fast reactive power change of up to the level of 900 Mvar. -- Abstract: The preliminary design for ITER AC/DC converters under the responsibility of the Korean Domestic Agency is performed on the basis of the engineering experience of previous R and D for a full-scale 6-pulse CS (Central Solenoid) converter unit. This paper describes key features of the preliminary design for the respective sub-systems; integrated self-supporting aluminium structure and symmetrical thyristor assembly for strong and reliable converters, optimised impedance of the converter transformer to limit short circuit current, coaxial-type AC bus bars to shield high magnetic field around wall penetrations, compact components to fit into given building space. The insulation and the minimisation of electrical loops of concrete rebar below the converter installations are essential to prevent floor heating. Required output voltage or current of converters is provided by a conventional controller. A master controller is designed to collect predicted reactive powers from each converter and deliver processed data to the reactive power compensation (RPC) system to improve the regulation speed of the RPC controller with fast feed-forward compensation under fast reactive power transients.

  6. Underwater Noise from a Wave Energy Converter is unlikely to Affect Marine Mammals

    DEFF Research Database (Denmark)

    Tougaard, Jakob

    2015-01-01

    Underwater noise was recorded from the Wavestar wave energy converter; a full-scale hydraulic point absorber, placed on a jack-up rig on the Danish North Sea coast. Noise was recorded 25 m from the converter with an autonomous recording unit (10 Hz to 20 kHz bandwidth). Median sound pressure leve...... on a jack-up rig. The results may thus not be directly transferable to other wave converter designs but do demonstrate that it is possible to harness wave energy without noise pollution to the marine environment.......Underwater noise was recorded from the Wavestar wave energy converter; a full-scale hydraulic point absorber, placed on a jack-up rig on the Danish North Sea coast. Noise was recorded 25 m from the converter with an autonomous recording unit (10 Hz to 20 kHz bandwidth). Median sound pressure levels...... were so low that they would barely be audible to marine mammals and the likelihood of negative impact from the noise appears minimal. A likely explanation for the low noise emissions is the construction of the converter where all moving parts, except for the absorbers themselves, are placed above water...

  7. Convertible shielding to ceramic breeding blanket

    International Nuclear Information System (INIS)

    Furuya, Kazuyuki; Kurasawa, Toshimasa; Sato, Satoshi; Nakahira, Masataka; Togami, Ikuhide; Hashimoto, Toshiyuki; Takatsu, Hideyuki; Kuroda, Toshimasa.

    1995-05-01

    Four concepts have been studied for the ITER convertible blanket: 1)Layered concept 2)BIT(Breeder-Inside-Tube)concept 3)BOT(Breeder-Out of-Tube)concept 4)BOT/mixed concept. All concepts use ceramic breeder and beryllium neutron multiplier, both in the shape of small spherical pebbles, 316SS structure, and H 2 O coolant (inlet/outlet temperatures : 100/150degC, pressure : 2 MPa). During the BPP, only beryllium pebbles (the primary pebble in case of BOT/mixed concept) are filled in the blanket for shielding purpose. Then, before the EPP operation, breeder pebbles will be additionally inserted into the blanket. Among possible conversion methods, wet method by liquid flow seems expecting for high and homogeneous pebble packing. Preliminary 1-D neutronics calculation shows that the BOT/mixed concept has the highest breeding and shielding performance. However, final selection should be done by R and D's and more detail investigation on blanket characteristics and fabricability. Required R and D's are also listed. With these efforts, the convertible blanket can be developed. However, the following should be noted. Though many of above R and D's are also necessary even for non-convertible blanket, R and D's on convertibility will be one of the most difficult parts and need significant efforts. Besides the installation of convertible blanket with required structures and lines for conversion will make the ITER basic machine more complicated. (author)

  8. Isolated and soft-switched power converter

    Science.gov (United States)

    Peng, Fang Zheng; Adams, Donald Joe

    2002-01-01

    An isolated and soft-switched power converter is used for DC/DC and DC/DC/AC power conversion. The power converter includes two resonant tank circuits coupled back-to-back through an isolation transformer. Each resonant tank circuit includes a pair of resonant capacitors connected in series as a resonant leg, a pair of tank capacitors connected in series as a tank leg, and a pair of switching devices with anti-parallel clamping diodes coupled in series as resonant switches and clamping devices for the resonant leg. The power converter is well suited for DC/DC and DC/DC/AC power conversion applications in which high-voltage isolation, DC to DC voltage boost, bidirectional power flow, and a minimal number of conventional switching components are important design objectives. For example, the power converter is especially well suited to electric vehicle applications and load-side electric generation and storage systems, and other applications in which these objectives are important. The power converter may be used for many different applications, including electric vehicles, hybrid combustion/electric vehicles, fuel-cell powered vehicles with low-voltage starting, remote power sources utilizing low-voltage DC power sources, such as photovoltaics and others, electric power backup systems, and load-side electric storage and generation systems.

  9. Ac-dc converter firing error detection

    International Nuclear Information System (INIS)

    Gould, O.L.

    1996-01-01

    Each of the twelve Booster Main Magnet Power Supply modules consist of two three-phase, full-wave rectifier bridges in series to provide a 560 VDC maximum output. The harmonic contents of the twelve-pulse ac-dc converter output are multiples of the 60 Hz ac power input, with a predominant 720 Hz signal greater than 14 dB in magnitude above the closest harmonic components at maximum output. The 720 Hz harmonic is typically greater than 20 dB below the 500 VDC output signal under normal operation. Extracting specific harmonics from the rectifier output signal of a 6, 12, or 24 pulse ac-dc converter allows the detection of SCR firing angle errors or complete misfires. A bandpass filter provides the input signal to a frequency-to-voltage converter. Comparing the output of the frequency-to-voltage converter to a reference voltage level provides an indication of the magnitude of the harmonics in the ac-dc converter output signal

  10. Understanding delta-sigma data converters

    CERN Document Server

    Pavan, Shanti; Temes, Gabor C

    2017-01-01

    This new edition introduces novel analysis and design techniques for delta-sigma (ΔΣ) converters in physical and conceptual terms, and includes new chapters that explore developments in the field over the last decade. This book explains the principles and operation of delta-sigma analog-to-digital converters (ADCs) in physical and conceptual terms in accordance with the most recent developments in the field. The interest of ΔΣ converter designers has shifted significantly over the past decade, due to many new applications for data converters at the far ends of the frequency spectrum. Continuous-time delta-sigma A/D converters with GHz clocks, of both lowpass and bandpass types, are required for wireless applications. At the other extreme, multiplexed ADCs with very narrow (sometimes 10 Hz wide) signal bandwidths, but very high accuracy are needed in the interfaces of biomedical and environmental sensors. To reflect the changing eeds of designers, the second edition includes significant new material on bo...

  11. Square function analysis of the Inductor-Converter Bridge

    International Nuclear Information System (INIS)

    Ehsani, M.; Kustom, R.L.

    1979-03-01

    The transfer of energy between two superconducting coils can be controlled with an Inductor-Converter Bridge (ICB) by changing the relative timing between the storage side bridge and the load side bridge. The average voltages on the coils have been previously derived as a function of relative timing between the two halves of the bridges and the relative currents in the two coils using a one-line, harmonic current source representation of each coil and its bridge network. Since the coil current in each of the ICB phases appears as bipolar rectangular pulses, an analysis based on unit step functions has been developed. The unit step function analysis leads to simple polynomial expressions relating the average coil voltages to relative timing. The new derivations are shown to have the same harmonic representation as previously developed. The polynomial expressions are more compatible to microprocessor control than are the harmonic function expressions

  12. Parties at the convention of the United Nations on climatic change and second meeting of the parties to the Kyoto protocol; Parties a la convention-cadre des Nations-Unies sur les changements climatiques et seconde reunion des parties au Protocole de Kyoto

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    Kenya hosted the second meeting of the Parties to the Kyoto Protocol in conjunction with the twelfth session of the conference of the Parties to the climatic change convention, in Nairobi from 6 to 17 November 2006. This document presents in a first part the key areas discussed at Nairobi; in a second part the international framework with the consequences of the Kyoto protocol implementation; and in the last part the demonstrable progresses of the France in the policy effects, tendencies concerning the greenhouse gases and the respect of the commitments. (A.L.B.)

  13. New logistics protocols for distributed interactive simulation

    Science.gov (United States)

    Taylor, Darrin; Morrison, John; Katz, Warren; Felton, Erik; Herman, Deborah A.

    1995-06-01

    In today's environment, the transportation and maintenance of military forces is nearly as important as combat operations. Rapid deployment to regions of low-intensity conflict will become a very common training scenario for the U.S. military. Thus it is desirable to apply distributed simulation technology to train logistics personnel in their combat support roles. Currently, distributed interactive simulation (DIS) only contains rudimentary logistics protocols. This paper introduces new protocols designed to handle the logistics problem. The Newtonian protocol takes a physics-based approach to modeling interactions on the simulation network. This protocol consists of a family of protocol data units (PDUs) which are used to communicate forces in different circumstances. The protocol implements a small set of physical relations. This represents a flexible and general mechanism to describe battlefield interactions between network entities. The migratory object protocol (MOP) family addresses the transfer of control. General mechanisms provide the means to simulate resupply, repair, and maintenance of entities at any level of abstraction (individual soldier to division). It can also increase the fidelity of mine laying, enable handover of weapons for terminal guidance, allow for the distribution of aggregate-level simulation entities, provide capabilities for the simulation of personnel, etc.

  14. Performance testing of self-powered detector signal converters at Dukovany nuclear power plant - stage 1

    International Nuclear Information System (INIS)

    Erben, O.; Hajek, P.; Zerola, L.; Karsulin, M.

    1990-11-01

    The converters were manufactured at the Institute of Nuclear Research, Rez. Dynamic functions of the converters were tested during the start-up of reactor unit 4, Dukovany nuclear power plant, and their stability during its normal operation. The results and evaluation of the measurements show a good performance of converters. They have a low offset, good stability and the values of current are in a good agreement with the values obtained using other methods. The values of insulation resistance are in a good agreement with the values obtained manually using the method of additional resistance. These converters are planned to be used in the upgraded in-service inspection system in WWER-440 nuclear power plants. (Z.S.) 9 tabs., 22 figs., 1 ref

  15. Parametric pendulum based wave energy converter

    Science.gov (United States)

    Yurchenko, Daniil; Alevras, Panagiotis

    2018-01-01

    The paper investigates the dynamics of a novel wave energy converter based on the parametrically excited pendulum. The herein developed concept of the parametric pendulum allows reducing the influence of the gravity force thereby significantly improving the device performance at a regular sea state, which could not be achieved in the earlier proposed original point-absorber design. The suggested design of a wave energy converter achieves a dominant rotational motion without any additional mechanisms, like a gearbox, or any active control involvement. Presented numerical results of deterministic and stochastic modeling clearly reflect the advantage of the proposed design. A set of experimental results confirms the numerical findings and validates the new design of a parametric pendulum based wave energy converter. Power harvesting potential of the novel device is also presented.

  16. Radioisotope thermionic converters for space applications

    International Nuclear Information System (INIS)

    Miskolczy, G.; Lieb, D.P.

    1990-01-01

    The recent history of radioisotope thermionics is reviewed, with emphasis on the U.S. programs, and the prospects for the future are assessed. In radioisotope thermionic converters the emitter heat is generated by the decay of a radioactive isotope. The thermionic converter emitter is mounted directly on a capsule containing the isotope. The rest of the capsule is generally insulated to reduce thermal loss. The development of isotope-fueled thermionic power systems for space application has been pursued since the late 1950's. The U.S. effort was concentrated on modular systems with alpha emitters as the isotope heat source. In the SNAP-13 program, the heat sources were Cerium isotopes and each module produced about 100 watts. The converters were planar diodes and the capsule was insulated with multi-foil insulation

  17. SIG Galileo final converter technical summary report

    International Nuclear Information System (INIS)

    Hinderman, J.D.

    1979-05-01

    The report is primarily concerned with the work performed for DOE on converter development and fabrication for the NASA Galileo Jupiter mission as a DOE prime contractor with interface primarily with Teledyne Energy Systems. The activities reported on were directed toward design, analysis and testing of modules and converters SN-1 thru SN-7 and attendant Quality Control and Reliability effort. Although assembly and testing of SN-1 was not accomplished due to the stop work order, the design was virtually completed and a significant amount of subcontracting and manufacturing of both module and converter components was underway. These subcontracting and manufacturing activities were selectively closed down depending upon degree of completion and material or hardware potential usage in the Technology Program

  18. Reliability of Power Electronic Converter Systems

    DEFF Research Database (Denmark)

    -link capacitance in power electronic converter systems; wind turbine systems; smart control strategies for improved reliability of power electronics system; lifetime modelling; power module lifetime test and state monitoring; tools for performance and reliability analysis of power electronics systems; fault...... for advancing the reliability, availability, system robustness, and maintainability of PECS at different levels of complexity. Drawing on the experience of an international team of experts, this book explores the reliability of PECS covering topics including an introduction to reliability engineering in power...... electronic converter systems; anomaly detection and remaining-life prediction for power electronics; reliability of DC-link capacitors in power electronic converters; reliability of power electronics packaging; modeling for life-time prediction of power semiconductor modules; minimization of DC...

  19. Data Converter for Multistandard Mobile Phones

    DEFF Research Database (Denmark)

    Yurttas, Aziz; Bruun, Erik; Jensen, Rasmus Glarborg

    2004-01-01

    This paper describes an analog to digital converter (ADC) for mobile communication systems using a direct down conversion architecture. The ADC can be programmed to meet the requirements of different communication standards, including GSM (Global System for Mobile communication) and WCDMA (Wideband...... Code Division Multiple Access). The ADC is realized with a pipeline ADC architecture for WCDMA and a Sigma-Delta architecture for GSM. In order to have an optimized area and power consumption, the basic building blocks (opamps) of the converters are shared between the two converter architectures....... The entire ADC consumes about 5.5 mW and occupies an active area of about 0.36 mm(2). A test circuit has been developed and fabricated and measurements show that both the required programmability and the required performance can be obtained using the proposed configurations....

  20. Converters for Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Yang, Yongheng

    2015-01-01

    Power electronics technology has become the enabling technology for the integration of distributed power generation systems (DPGS) such as offshore wind turbine power systems and commercial photovoltaic power plants. Depending on the applications, a vast array of DPGS-based power converter...... topologies has been developed and more are coming into the market in order to achieve an efficient and reliable power conversion from the renewables. In addition, stringent demands from both the distribution system operators and the consumers have been imposed on the renewable-based DPGS. This article...... presents an overview of the power converters for the DPGS, mainly based on wind turbine systems and photovoltaic systems, covering a wide range of applications. Moreover, the modulation schemes and interfacing power filters for the power converters are also exemplified. Finally, the general control...

  1. Measurements of neutron spectrum from uranium converter

    International Nuclear Information System (INIS)

    Ninkovic, M.; Sotic, O.; Marinkovic, S.

    1978-01-01

    The procedure for determination of energetic distribution of neutrons by the multisphere technique is given. The theoretical basis and features of the method are explained. The spectral distribution of neutrons emerging from the neutron converter constructed at the bare reactor assembly RB, has been determined applying the existing computer programme and literature data for the energetic dependence functions of spheres of various diameters. The obtained spectral distribution has a specific maximum in the domain of fast neutrons, justifying thus the reacton for the construction of the converter. The neutron spectrum data obtained and given in this report are very important for the use of the converter in neutron dosimetry and radiation protection, as well as in the radiobiology, shielding, reactor physics etc. (author)

  2. Lithium converter of reactor neutrinos in antineutrino

    International Nuclear Information System (INIS)

    Lyutostanskij, Yu.S.; Lyashuk, V.I.

    1989-01-01

    The questions of developing lithium converter of the reactor neutrons in antineutrino operating at dynamic regime in the scheme with the cycle circulation of the high-purified lithium (by 7 Li isotope) through the converter are considered. The scheme allows to localize the 8 Li β-decay (T 1/2 =0.84 s) in the reservoir near the detector and so to design the hard-spectrum lithium ν-tilde e -source (E max ≅13 MeV) at the distance from the active zone being the soft-spectrum ν-tilde e -source. The expressions for the lithium ν-tilde e flux from the converter, reservoir and conveyance channel are obtained. 9 refs.; 8 figs.; 1 tab

  3. Metamaterial polarization converter analysis: limits of performance

    DEFF Research Database (Denmark)

    Markovich, Dmitry L.; Andryieuski, Andrei; Zalkovskij, Maksim

    2013-01-01

    and a single layer with a ground plane can have 100 % polarization conversion efficiency. We tested our conclusions numerically reaching the designated limits of efficiency using a simple metamaterial design. Our general analysis provides useful guidelines for the metamaterial polarization converter design......In this paper, we analyze the theoretical limits of a metamaterial-based converter with orthogonal linear eigenpolarizations that allow linear-to-elliptical polarization transformation with any desired ellipticity and ellipse orientation. We employ the transmission line approach providing a needed...... level of the design generalization. Our analysis reveals that the maximal conversion efficiency for transmission through a single metamaterial layer is 50 %, while the realistic reflection configuration can give the conversion efficiency up to 90 %. We show that a double layer transmission converter...

  4. Self-oscillating resonant power converter

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to resonant power converters and inverters comprising a self-oscillating feedback loop coupled from a switch output to a control input of a switching network comprising one or more semiconductor switches. The self-oscillating feedback loop sets a switching frequency...... of the power converter and comprises a first intrinsic switch capacitance coupled between a switch output and a control input of the switching network and a first inductor. The first inductor is coupled in-between a first bias voltage source and the control input of the switching network and has...... a substantially fixed inductance. The first bias voltage source is configured to generate an adjustable bias voltage applied to the first inductor. The output voltage of the power converter is controlled in a flexible and rapid manner by controlling the adjustable bias voltage....

  5. Successfully converting mine maps to CAD

    Energy Technology Data Exchange (ETDEWEB)

    Munn, M.D. (Image Conversion Services, Inc., Salt Lake City, UT (USA))

    1991-03-01

    Procedures followed by computer service bureaus to convert paper drawing to digital files that can be used by CAD systems are described. The conversion involves laser scanning of original drawings to produce an 'inactive image' (a form suitable for many drawings that do not need to be changed). Using optical character recognition software the image is then vectorized or converted from raster format to geometric elements usable in a CAD system. The vectorized image can then be cleaned up corrected and changed at the CAD workstation. 4 figs.

  6. IGBT Based DC/DC Converter

    Directory of Open Access Journals (Sweden)

    M. Akherraz

    1997-12-01

    Full Text Available This paper presents an in-depth analytical and experimental investigation of an indirect DC-DC converter. The DC-AC conversion is a full bridge based on IGBT power modules, and the AC-DC conversion is done via a high  frequency AC link and a first diode bridge. The AC link, which consists of snubbing capacitors and a variable air-gap transformer, is analytically designed to fulfill Zero Voltage commutation requirement. The proposed converter is simulated using PSPICE and a prototype is designed built and tested in the laboratory. PSPICE simulation and experimental results are presented and compared.

  7. SlaVaComp Fonts Converter

    Directory of Open Access Journals (Sweden)

    Simon Skilevic

    2013-12-01

    Full Text Available This paper presents a fonts converter that was developed as a part of the Freiburg project on historical corpus linguistics. The tool named SlaVaComp-Konvertierer converts Church Slavonic texts digitized with non-Unicode fonts into the Unicode format without any loss of information contained in the original file and without damage to the original formatting. It is suitable for the conversion of all idiosyncratic fonts—not only Church Slavonic—and therefore can be used not only in Palaeoslavistic, but also in all historical and philological studies.

  8. High Efficiency Reversible Fuel Cell Power Converter

    DEFF Research Database (Denmark)

    Pittini, Riccardo

    as well as different dc-ac and dc-dc converter topologies are presented and analyzed. A new ac-dc topology for high efficiency data center applications is proposed and an efficiency characterization based on the fuel cell stack I-V characteristic curve is presented. The second part discusses the main...... converter components. Wide bandgap power semiconductors are introduced due to their superior performance in comparison to traditional silicon power devices. The analysis presents a study based on switching loss measurements performed on Si IGBTs, SiC JFETs, SiC MOSFETs and their respective gate drivers...

  9. Converting ODM Metadata to FHIR Questionnaire Resources.

    Science.gov (United States)

    Doods, Justin; Neuhaus, Philipp; Dugas, Martin

    2016-01-01

    Interoperability between systems and data sharing between domains is becoming more and more important. The portal medical-data-models.org offers more than 5.300 UMLS annotated forms in CDISC ODM format in order to support interoperability, but several additional export formats are available. CDISC's ODM and HL7's framework FHIR Questionnaire resource were analyzed, a mapping between elements created and a converter implemented. The developed converter was integrated into the portal with FHIR Questionnaire XML or JSON download options. New FHIR applications can now use this large library of forms.

  10. Combination solar photovoltaic heat engine energy converter

    Science.gov (United States)

    Chubb, Donald L.

    1987-01-01

    A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

  11. Solar energy converter using surface plasma waves

    Science.gov (United States)

    Anderson, L. M. (Inventor)

    1984-01-01

    Sunlight is dispersed over a diffraction grating formed on the surface of a conducting film on a substrate. The angular dispersion controls the effective grating period so that a matching spectrum of surface plasmons is excited for parallel processing on the conducting film. The resulting surface plasmons carry energy to an array of inelastic tunnel diodes. This solar energy converter does not require different materials for each frequency band, and sunlight is directly converted to electricity in an efficient manner by extracting more energy from the more energetic photons.

  12. SP-100 converter multicouple thermoelectric cell

    International Nuclear Information System (INIS)

    Kull, R.A.; Terrill, W.R.

    1990-01-01

    The General Electric Company is under contract to DOE to design, fabricate, and test an SP-100 Ground Engineering System. This paper provides a description of the SP-100 space reactor power system configuration, and a more detailed description of the power conversion subsystem (PCSS) and the key building block of the power converter, the thermoelectric cell. The functions of the various elements of the PCSS and the cells are also presented. These cells convert the thermal energy from the reactor into electrical power at the desired voltage while being conductively coupled to the hot and cold side heat exchangers to maximize the power output and system specific power

  13. A linear temperature-to-frequency converter

    DEFF Research Database (Denmark)

    Løvborg, Leif

    1965-01-01

    , and that the maximum value of the temperature-frequency coefficient beta in this point is-1/3 alpha, where a is the temperature coefficient of the thermistor at the corresponding temperature. Curves showing the range in which the converter is expected to be linear to within plusmn0.1 degC are given. A laboratory......-built converter having beta = 1.0% degC-1 at 25degC is found to be linear to within plusmn0. 1 degC from 10 to 40degC....

  14. Network protocols and sockets

    OpenAIRE

    BALEJ, Marek

    2010-01-01

    My work will deal with network protocols and sockets and their use in programming language C#. It will therefore deal programming network applications on the platform .NET from Microsoft and instruments, which C# provides to us. There will describe the tools and methods for programming network applications, and shows a description and sample applications that work with sockets and application protocols.

  15. A Dual-Buck–Boost AC/DC Converter for DC Nanogrid With Three Terminal Outputs

    DEFF Research Database (Denmark)

    Wu, Weimin; Wang, Houqing; Liu, Yuan

    2017-01-01

    Due to the widely used dc characterized loads and more distributed power generation sources, the dc nanogrid becomes more and more popular, and it is seen as an alternative to the ac grid. For safety considerations, the dc nanogrid should provide reliable grounding for the residential loads...... such as the low-voltage ac power system. There are three typical grounding configurations for a dc nanogrid: the united grounding, the unidirectional grounding, and the virtual isolated grounding. Each grounding configuration has its own specifications to ac/dc converters. In this paper, a dual-buck-boost ac/dc...... converter for use in the united-grounding-configuration-based dc nanogrid with three terminal outputs is proposed. The working principle of this converter is presented in detail through analyzing the equivalent circuits. Experiments are carried out to verify the theoretical analysis....

  16. Optimal control of a wave energy converter

    NARCIS (Netherlands)

    Hendrikx, R.W.M.; Leth, J.; Andersen, P; Heemels, W.P.M.H.

    2017-01-01

    The optimal control strategy for a wave energy converter (WEC) with constraints on the control torque is investigated. The goal is to optimize the total energy delivered to the electricity grid. Using Pontryagin's maximum principle, the solution is found to be singular-bang. Using higher order

  17. Online Scheduling in Distributed Message Converter Systems

    NARCIS (Netherlands)

    Risse, Thomas; Wombacher, Andreas; Surridge, Mike; Taylor, Steve; Aberer, Karl

    The optimal distribution of jobs among hosts in distributed environments is an important factor to achieve high performance. The optimal strategy depends on the application. In this paper we present a new online scheduling strategy for distributed EDI converter system. The strategy is based on the

  18. Hybrid switch for resonant power converters

    Science.gov (United States)

    Lai, Jih-Sheng; Yu, Wensong

    2014-09-09

    A hybrid switch comprising two semiconductor switches connected in parallel but having different voltage drop characteristics as a function of current facilitates attainment of zero voltage switching and reduces conduction losses to complement reduction of switching losses achieved through zero voltage switching in power converters such as high-current inverters.

  19. Mathematical modeling of the flash converting process

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, H.Y.; Perez-Tello, M.; Riihilahti, K.M. [Utah Univ., Salt Lake City, UT (United States)

    1996-12-31

    An axisymmetric mathematical model for the Kennecott-Outokumpu flash converting process for converting solid copper matte to copper is presented. The model is an adaptation of the comprehensive mathematical model formerly developed at the University of Utah for the flash smelting of copper concentrates. The model incorporates the transport of momentum, heat, mass, and reaction kinetics between gas and particles in a particle-laden turbulent gas jet. The standard k-{epsilon} model is used to describe gas-phase turbulence in an Eulerian framework. The particle-phase is treated from a Lagrangian viewpoint which is coupled to the gas-phase via the source terms in the Eulerian gas-phase governing equations. Matte particles were represented as Cu{sub 2}S yFeS, and assumed to undergo homogeneous oxidation to Cu{sub 2}O, Fe{sub 3}O{sub 4}, and SO{sub 2}. A reaction kinetics mechanism involving both external mass transfer of oxygen gas to the particle surface and diffusion of oxygen through the porous oxide layer is proposed to estimate the particle oxidation rate Predictions of the mathematical model were compared with the experimental data collected in a bench-scale flash converting facility. Good agreement between the model predictions and the measurements was obtained. The model was used to study the effect of different gas-injection configurations on the overall fluid dynamics in a commercial size flash converting shaft. (author)

  20. Convertible security design and contract innovation

    NARCIS (Netherlands)

    Lewis, C.M.; Verwijmeren, P.

    2011-01-01

    This paper studies convertible security design for a sample of 814 issuers over the years 2000 through 2007. Using a nested logit model, we examine how firms choose fixed income claims and the method of payment. We find that fixed income claims are chosen to reduce corporate income taxes, minimize

  1. Angiotensin Converting Enzyme Insertion/Deletion Gene ...

    African Journals Online (AJOL)

    Angiotensin Converting Enzyme Insertion/Deletion Gene Polymorphism: An Observational Study among Diabetic Hypertensive Subjects in Malaysia. ... Methods: The pharmacological effect of ACE inhibition on mean arterial pressure (MAP) and glomerular filtration rate (GFR) were observed among a total of 62 subjects for ...

  2. Development of the Wave Energy Converter

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter; Sørensen, Hans Christian

    2000-01-01

    The development of the wave energy converter Wave Dragon (WD) is presented. The WD is based on the overtopping principle. Initially a description of the WD is given. Then the development over time in terms of the various research and development projects working with the concept is described. Thi...

  3. Lathe converted for grinding aspheric surfaces

    Science.gov (United States)

    Larmer, J. W.; Levinsohn, M.; Mc Craw, D.; Pessagno, E. H.; Taub, F. J.

    1964-01-01

    A standard overarm tracing lathe converted by the addition of an independently driven diamond grinding wheel is used for grinding aspheric surfaces. The motion of the wheel is controlled by the lathe air tracer following the template which produces the desired aspheric profile.

  4. Mathematical modeling of the flash converting process

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, H Y; Perez-Tello, M; Riihilahti, K M [Utah Univ., Salt Lake City, UT (United States)

    1997-12-31

    An axisymmetric mathematical model for the Kennecott-Outokumpu flash converting process for converting solid copper matte to copper is presented. The model is an adaptation of the comprehensive mathematical model formerly developed at the University of Utah for the flash smelting of copper concentrates. The model incorporates the transport of momentum, heat, mass, and reaction kinetics between gas and particles in a particle-laden turbulent gas jet. The standard k-{epsilon} model is used to describe gas-phase turbulence in an Eulerian framework. The particle-phase is treated from a Lagrangian viewpoint which is coupled to the gas-phase via the source terms in the Eulerian gas-phase governing equations. Matte particles were represented as Cu{sub 2}S yFeS, and assumed to undergo homogeneous oxidation to Cu{sub 2}O, Fe{sub 3}O{sub 4}, and SO{sub 2}. A reaction kinetics mechanism involving both external mass transfer of oxygen gas to the particle surface and diffusion of oxygen through the porous oxide layer is proposed to estimate the particle oxidation rate Predictions of the mathematical model were compared with the experimental data collected in a bench-scale flash converting facility. Good agreement between the model predictions and the measurements was obtained. The model was used to study the effect of different gas-injection configurations on the overall fluid dynamics in a commercial size flash converting shaft. (author)

  5. Power electronics converters for wind turbine systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Liserre, Marco; Ma, Ke

    2011-01-01

    The steady growth of installed wind power which reached 200 GW capacity in 2010, together with the up-scaling of the single wind turbine power capability - 7 MW’s has been announced by manufacturers - has pushed the research and development of power converters towards full scale power conversion,...

  6. Power Electronics Converters for Wind Turbine Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Liserre, Marco; Ma, Ke

    2012-01-01

    The steady growth of installed wind power together with the upscaling of the single wind turbine power capability has pushed the research and development of power converters toward full-scale power conversion, lowered cost pr kW, increased power density, and also the need for higher reliability. ...

  7. National Ignition Facility frequency converter development

    International Nuclear Information System (INIS)

    Barker, C.E.; Auerbach, J.M.; Adams, C.H.

    1996-01-01

    A preliminary error budget for the third harmonic converter for the National Ignition Facility (NIF) laser driver has been developed using a root-sum-square-accumulation of error sources. Such a budget sets an upper bound on the allowable magnitude of the various effects that reduce conversion efficiency. Development efforts on crystal mounting technology and crystal quality studies are discussed

  8. Oxygen activity measurements in simulated converter matte

    CSIR Research Space (South Africa)

    Tshilombo, KG

    2007-01-01

    Full Text Available to the composition of the gas atmosphere over the melt. The measured oxygen activity was generally close to that predicted by FactSage calculations. This indicates that such oxygen activity measurements could be useful to monitor iron removal during converting...

  9. Generalized modular multilevel converter and modulation

    DEFF Research Database (Denmark)

    Liu, Hui; Loh, Poh Chiang; Blaabjerg, Frede

    2014-01-01

    converters regulating a power grid. The generalized topology derived and notated as GMMC can then be altered to create various types of MMC, including the traditional topology that is presently well-known. This effort has not been previously discussed, and may smoothen the understanding of MMC operation...

  10. Converting skeletal structures to quad dominant meshes

    DEFF Research Database (Denmark)

    Bærentzen, Jakob Andreas; Misztal, Marek Krzysztof; Welnicka, Katarzyna

    2012-01-01

    We propose the Skeleton to Quad-dominant polygonal Mesh algorithm (SQM), which converts skeletal structures to meshes composed entirely of polar and annular regions. Both types of regions have a regular structure where all faces are quads except for a single ring of triangles at the center of each...

  11. Synthetic Applications of Nitrile-Converting Enzymes

    Czech Academy of Sciences Publication Activity Database

    Martínková, Ludmila; Mylerová, Veronika

    2003-01-01

    Roč. 7, - (2003), s. 1279-1295 ISSN 1385-2728 R&D Projects: GA AV ČR IAA4020213 Institutional research plan: CEZ:AV0Z5020903 Keywords : nitrile * converting * enzymes Subject RIV: EE - Microbiology, Virology Impact factor: 2.521, year: 2003

  12. multilevel buck converter for automotive electrical load

    African Journals Online (AJOL)

    ... from internal combustion engine (ICE). The mass production of the hybrid electric (HE) and the electric vehicle (EV) is still awaited due to subsystem inefficiencies. Increasing the efficiencies of the power converters within subsystems of these HEVs and EVs will increase the performance of the new transportation vehicles.

  13. Convertible bonds and bank risk-taking

    NARCIS (Netherlands)

    Martynova, N.; Perotti, E.

    2015-01-01

    We study how contingent capital that converts in equity ahead of default affects bankrisk-shifting. Going concern conversion restores equity value in highly levered states,thus reducing heightened risk incentives. In contrast, conversion at default for traditionalbail-inable debt has no effect on

  14. Process of converting heavy hydrocarbons, etc

    Energy Technology Data Exchange (ETDEWEB)

    Thiele, F C

    1921-05-27

    A modification is described of the process of the principal Patent 373,060 for splitting and converting heavy hydrocarbons into low-boiling lighter products or into cylinder oil, characterized in that, in place of petroleum, brown-coal oil, shale oil, or the like is distilled in the presence of hydrosilicate as a catalyzer or is heated with refluxing.

  15. Bidirectional converter interface for a battery energy storage test bench

    DEFF Research Database (Denmark)

    Trintis, Ionut; Thomas, Stephan; Blank, Tobias

    2011-01-01

    This paper presents the bidirectional converter interface for a 6 kV battery energy storage test bench. The power electronic interface consists a two stage converter topology having a low voltage dc-ac grid connected converter and a new dual active bridge dc-dc converter with high transformation...

  16. The rise and demise of the convertible arbitrage strategy

    NARCIS (Netherlands)

    Loncarski, I.; Ter Horst, J.R.; Veld, C.H.

    2009-01-01

    This article analyzes convertible arbitrage, one of the most successful hedge fund strategies. The aim of the strategy is to exploit underpricing of convertible bonds by taking a long position in a convertible and a short position in the underlying asset. The authors find that convertible bonds are

  17. A Fast Time-to-Pulse Height Converter

    Energy Technology Data Exchange (ETDEWEB)

    Aspelund, O

    1962-12-15

    A fast time-to-pulse height converter representing a development of Green and Bell's gated beam converter is described. The converter is compatible with 2 input pulses in the stop channel and exhibits excellent linearity and time resolution properties. High stability and large output pulses are obtained by using a large time constant in the converting network.

  18. Do Convertible Bond Issuers Cater to Investor Demand?

    NARCIS (Netherlands)

    de Jong, Abe; Duca, Eric; Dutordoir, Marie

    2013-01-01

    We examine the impact of fluctuations in investor demand for convertible securities on convertible bond issue volumes, pricing, and design. We find evidence of a positive impact of investor demand proxies on convertible bond issue volumes. We also document significantly lower convertible bond

  19. Measured and projected performance of plasma direct converters

    International Nuclear Information System (INIS)

    Barr, W.L.; Moir, R.W.

    1981-01-01

    Test results from two plasma direct converters and their predicted cost and performance on tandem mirror fusion reactors are present. The tests were done at high power density (approx. 70 W/cm 2 ) in steady state to simulate the predicted conditions in a reactor. A single stage unit and a two-stage unit of the Venetian blind type were tested at up to 100 kV and 6 kW for a total time of about 80 hours. Measured efficiencies, when projected to a reactor, are typically about 50% for a single stage unit and 60 to 70% for a two-stage unit, depending on the energy distribution of the ions, the degree of subdivision of the collectors, and on the gas pressure. The high ambipolar potential in tandem mirror devices makes this good efficiency possible. When radiatively cooled grids are used, the incident power density is limited to about 100 W/cm 2 by the thermionic emission of electrons

  20. Reference Model 5 (RM5): Oscillating Surge Wave Energy Converter

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Y. H. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jenne, D. S. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Thresher, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Copping, A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Geerlofs, S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hanna, L. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-01-01

    This report is an addendum to SAND2013-9040: Methodology for Design and Economic Analysis of Marine Energy Conversion (MEC) Technologies. This report describes an Oscillating Water Column Wave Energy Converter (OSWEC) reference model design in a complementary manner to Reference Models 1-4 contained in the above report. A conceptual design for a taut moored oscillating surge wave energy converter was developed. The design had an annual electrical power of 108 kilowatts (kW), rated power of 360 kW, and intended deployment at water depths between 50 m and 100 m. The study includes structural analysis, power output estimation, a hydraulic power conversion chain system, and mooring designs. The results were used to estimate device capital cost and annual operation and maintenance costs. The device performance and costs were used for the economic analysis, following the methodology presented in SAND2013-9040 that included costs for designing, manufacturing, deploying, and operating commercial-scale MEC arrays up to 100 devices. The levelized cost of energy estimated for the Reference Model 5 OSWEC, presented in this report, was for a single device and arrays of 10, 50, and 100 units, and it enabled the economic analysis to account for cost reductions associated with economies of scale. The baseline commercial levelized cost of energy estimate for the Reference Model 5 device in an array comprised of 10 units is $1.44/kilowatt-hour (kWh), and the value drops to approximately $0.69/kWh for an array of 100 units.

  1. A novel harmonic control approach of distributed generation converters in a weak microgrid

    DEFF Research Database (Denmark)

    Ding, Guangqian; Gao, Feng; Tang, Yi

    2014-01-01

    as well as the long distance communication between the PCC and the converter are fully eliminated. In order to avoid overcompensation, a harmonic current limitation algorithm is implemented in the control loop. bBy properly dispatching the harmonic compensation capability, multiple DG unites can...

  2. Plug-and-Play Design of Current Controllers for Grid-feeding Converters in DC Microgrids

    DEFF Research Database (Denmark)

    Han, Renke; Tucci, Michele; Soloperto, Raffaele

    2017-01-01

    In this paper, we address the problem of synthesizing decentralized current controllers for grid-feeding converters of current-controlled distributed generation units (CDGUs) in dc microgrids (MGs). Notably, a plug-and-play (PnP) design procedure is proposed to achieve grid-feeding current tracking...

  3. Multi-cell DC-DC converter with high step-down voltage ratio

    NARCIS (Netherlands)

    Tibola, G.; Duarte, J.L.; Blinov, A.

    2015-01-01

    The use of high voltage allows a power processing system to operate with low currents, improving efficiency. Nevertheless, final applications usually require low voltage inlet, which can be provided using modular multilevel converters submodules, for instance. However, every submodule's gate-unit

  4. High-frequency matrix converter with square wave input

    Science.gov (United States)

    Carr, Joseph Alexander; Balda, Juan Carlos

    2015-03-31

    A device for producing an alternating current output voltage from a high-frequency, square-wave input voltage comprising, high-frequency, square-wave input a matrix converter and a control system. The matrix converter comprises a plurality of electrical switches. The high-frequency input and the matrix converter are electrically connected to each other. The control system is connected to each switch of the matrix converter. The control system is electrically connected to the input of the matrix converter. The control system is configured to operate each electrical switch of the matrix converter converting a high-frequency, square-wave input voltage across the first input port of the matrix converter and the second input port of the matrix converter to an alternating current output voltage at the output of the matrix converter.

  5. A resonant dc-dc power converter assembly

    DEFF Research Database (Denmark)

    2015-01-01

    The present invention relates to a resonant DC-DC power converter assembly comprising a first resonant DC-DC power converter and a second resonant DC-DC power converter having identical circuit topologies. A first inductor of the first resonant DC-DC power converter and a second inductor of the s......The present invention relates to a resonant DC-DC power converter assembly comprising a first resonant DC-DC power converter and a second resonant DC-DC power converter having identical circuit topologies. A first inductor of the first resonant DC-DC power converter and a second inductor...... of the second resonant DC-DC power converter are configured for magnetically coupling the first and second resonant DC-DC power converters to each other to forcing substantially 180 degrees phase shift, or forcing substantially 0 degree phase shift, between corresponding resonant voltage waveforms of the first...

  6. Dividend-Protected Convertible Bonds and the Disappearance

    OpenAIRE

    Bruce D. Grundy; Patrick Verwijmeren

    2012-01-01

    Firms have not historically called their convertible bonds as soon as they could force conversion. Various explanations for the delay rely on the size of the dividends that bondholders forgo so long as they do not convert. We investigate an important change in convertible security design, namely that more than 95 percent of recent convertible bond issues are dividend-protected. Dividend protection means that the conversion value of the shares into which a bond is convertible is unaffected by ...

  7. Imbalance between pulmonary angiotensin-converting enzyme and angiotensin-converting enzyme 2 activity in acute respiratory distress syndrome

    NARCIS (Netherlands)

    Wösten-van Asperen, Roelie M.; Bos, Albert P.; Bem, Reinout A.; Dierdorp, Barbara S.; Dekker, Tamara; van Goor, Harry; Kamilic, Jelena; van der Loos, Chris M.; van den Berg, Elske; Bruijn, Martijn; van Woensel, Job B.; Lutter, René

    2013-01-01

    Angiotensin-converting enzyme and its effector peptide angiotensin II have been implicated in the pathogenesis of acute respiratory distress syndrome. Recently, angiotensin-converting enzyme 2 was identified as the counter-regulatory enzyme of angiotensin-converting enzyme that converts angiotensin

  8. Imbalance between pulmonary angiotensin-converting enzyme and angiotensin-converting enzyme 2 activity in acute respiratory distress syndrome

    NARCIS (Netherlands)

    Wosten-van Asperen, Roelie M.; Bos, Albert; Bem, Reinout A.; Dierdorp, Barbara S.; Dekker, Tamara; van Goor, Harry; Kamilic, Jelena; van der Loos, Chris M.; van den Berg, Elske; Bruijn, Martijn; van Woensel, Job B.; Lutter, Rene

    2013-01-01

    Objective: Angiotensin-converting enzyme and its effector peptide angiotensin II have been implicated in the pathogenesis of acute respiratory distress syndrome. Recently, angiotensin-converting enzyme 2 was identified as the counter-regulatory enzyme of angiotensin-converting enzyme that converts

  9. Protocol Fuel Mix reporting

    International Nuclear Information System (INIS)

    2002-07-01

    The protocol in this document describes a method for an Electricity Distribution Company (EDC) to account for the fuel mix of electricity that it delivers to its customers, based on the best available information. Own production, purchase and sale of electricity, and certificates trading are taken into account. In chapter 2 the actual protocol is outlined. In the appendixes additional (supporting) information is given: (A) Dutch Standard Fuel Mix, 2000; (B) Calculation of the Dutch Standard fuel mix; (C) Procedures to estimate and benchmark the fuel mix; (D) Quality management; (E) External verification; (F) Recommendation for further development of the protocol; (G) Reporting examples

  10. Coded Splitting Tree Protocols

    DEFF Research Database (Denmark)

    Sørensen, Jesper Hemming; Stefanovic, Cedomir; Popovski, Petar

    2013-01-01

    This paper presents a novel approach to multiple access control called coded splitting tree protocol. The approach builds on the known tree splitting protocols, code structure and successive interference cancellation (SIC). Several instances of the tree splitting protocol are initiated, each...... instance is terminated prematurely and subsequently iterated. The combined set of leaves from all the tree instances can then be viewed as a graph code, which is decodable using belief propagation. The main design problem is determining the order of splitting, which enables successful decoding as early...

  11. Playing With Population Protocols

    Directory of Open Access Journals (Sweden)

    Xavier Koegler

    2009-06-01

    Full Text Available Population protocols have been introduced as a model of sensor networks consisting of very limited mobile agents with no control over their own movement: A collection of anonymous agents, modeled by finite automata, interact in pairs according to some rules. Predicates on the initial configurations that can be computed by such protocols have been characterized under several hypotheses. We discuss here whether and when the rules of interactions between agents can be seen as a game from game theory. We do so by discussing several basic protocols.

  12. ATM and Internet protocol

    CERN Document Server

    Bentall, M; Turton, B

    1998-01-01

    Asynchronous Transfer Mode (ATM) is a protocol that allows data, sound and video being transferred between independent networks via ISDN links to be supplied to, and interpreted by, the various system protocols.ATM and Internet Protocol explains the working of the ATM and B-ISDN network for readers with a basic understanding of telecommunications. It provides a handy reference to everyone working with ATM who may not require the full standards in detail, but need a comprehensive guide to ATM. A substantial section is devoted to the problems of running IP over ATM and there is some discussion o

  13. From small to insignificant. Climate impact of the Kyoto Protocol with and without US

    International Nuclear Information System (INIS)

    Hagem, Cathrine; Holtsmark, Bjart

    2001-06-01

    American president George W. Bush has declared that he will not ask the Senate to ratify the Kyoto Protocol. This commentary explores the potential impact of implementing the Kyoto Protocol without the participation of the United States. Because, in practice, the United States would have taken on a relatively large share of the Protocol's abatement commitments, we conclude that implementing the Protocol without the participation of United States will lead to significantly less reductions in global emissions. The international permit price will be considerably lower if the United States does not participate. (author)

  14. Development of a current-type PWM converter with high power factor. 1

    International Nuclear Information System (INIS)

    Miura, Yushi; Matsukawa, Makoto; Miyachi, Kengo; Kimura, Toyoaki

    1998-01-01

    A power supply system for superconducting poloidal field coils of a next generation tokamak-type fusion device can be operated on the relatively low voltage for the duration of discharge except the plasma initiation. In the case of the conventional phase-controlled thyristor converters are adopted in such a system, the input power factor would be low in average, and a reactive power fluctuation caused by the change of DC output voltage may produce serious effects on the commercial transmission line. From the above viewpoint, a current-type PWM (Pulse Width Modulation) converter, which can work with the power factor of unity for the input power, is regarded as one of the promising candidates of the converters for the power supplies of next generation fusion devices. Hence, a 100kW-class current-type PWM converter has been developed by using IGBT (Insulated Gate Bipolar Transistor) as switching devices. In this development, the basic performance has been preliminary investigated whether this converter is applicable to the power supply for the next generation fusion device. In addition, two different PWM control methods were examined whether these methods can realize a unit power factor and suppress the transient oscillation of converter input current at the same time in case that the reference of DC output current is changed rapidly. (author)

  15. Modelling and simulation of current fed dc to dc converter for PHEV applications using renewable source

    Science.gov (United States)

    Milind Metha, Manish; Tutki, Sanjay; Rajan, Aju; Elangovan, D.; Arunkumar, G.

    2017-11-01

    With the current rate of depletion of the fossil fuel the need to switch on to the renewable energy sources is the need of the hour. Thus the need for new and efficient converters arises so as to replace the existing less efficient diesel and petroleum IC engines with renewable energy sources. The PHEVs, which have been launched in the market, and Upcoming PHEVs have converters around 380V to 400V generated with a power range between 2KW to 2.8KW. The fundamental target of this paper is to plan a productive converter keeping in mind cost and size restriction. In this paper, a two-stage dc-dc converter is proposed. The proposed converter is utilized to venture up a voltage from 24V (photovoltaic source) to a yield voltage of 400V to take care of a power demand of 2.4kW for a plug-in hybrid electric vehicle (PHEV) application considering the real time scenario of PHEV. This paper talks about in detail why the current fed converter is utilized alongside a voltage doubler thus minimizing the transformer turns thereby reducing the overall size of the final product. Simulation results along with calculation for the duty cycle of the firing sequence for different value of transformer turns are presented for a prototype unit.

  16. Variability in donation after cardiac death protocols: a national survey.

    Science.gov (United States)

    Fugate, Jennifer E; Stadtler, Maria; Rabinstein, Alejandro A; Wijdicks, Eelco F M

    2011-02-27

    As donation after cardiac death practices expand, the number of institutional policies is increasing. We contacted organ procurement organizations throughout the United States and requested protocols in hospitals in their donor service areas. Sixty-four protocols were obtained with representation from 16 different states. The terminology and recommended practices varied substantially. The methods for death determination were not specified in 28 (44%) protocols. Most adhered to a 2- to 5-min observation time between circulatory arrest and organ procurement, but 10 (16%) provided no information. This variability reveals a need to define a uniform standard in donation after cardiac death protocols and death determination practices.

  17. A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

    Directory of Open Access Journals (Sweden)

    Liu Longchen

    2016-01-01

    Full Text Available The converter valve is the core equipment in the HVDC power transmission system, a+-nd its performance has a direct effect on the reliability, stability and efficiency of the whole power system. As the basic unit of HVDC converter valve, the thyristor level needs to be test routinely in order to grasp the state of the converter valve equipment. Therefore, it is urgent to develop a novel synthetic test system for the thyristor level with thyristor control unit (TCU. However, currently there is no specific test scheme for the thyristor level of HVDC converter valve. In this paper, the synthetic test principle, content and methods for the thyristor level with TCU are presented based on the analysis of the thyristor reverse recovery characteristic and the IEC technology standard. And a transient high-voltage pulse is applied to the thyristor level during its reverse recovery period in order to test the characteristics of thyristor level. Then, the synthetic test system for the thyristor level is applied to the converter valve test of ±800 kV HVDC power transmission project, and the practical test result verifies the reasonability and validity of the proposed synthetic test system.

  18. Unit Monitors Manchester-Format Data Buses

    Science.gov (United States)

    Amador, Jose J.

    1994-01-01

    Circuit card converts data signals into convenient hexadecimal form for troubleshooting. Bus-monitoring unit converts data signals from Manchester II format used on data bus into hexadecimal format. Monitoring circuit causes hexadecimal words to display on video terminal, where test engineer compares them with hexadecimal records for troubleshooting. Circuit monitors one bus or two buses simultaneously.

  19. Dual Converter Fed Open-End Transformer Topology with Parallel Converters and Integrated Magnetics

    DEFF Research Database (Denmark)

    Gohil, Ghanshyamsinh Vijaysinh; Bede, Lorand; Teodorescu, Remus

    2016-01-01

    that flows between the parallel interleaved VSCs. An integrated inductor is proposed which suppresses the circulating current in both the converter groups. In addition, the functionality of the line filter inductor is also integrated. Flux in various parts of the integrated inductor is analyzed and a design......A converter system for high power applications, connected to a medium-voltage network using a stepup transformer, is presented in this paper. The converterside winding of the transformer is configured as an openend and both the ends of the windings are fed from two different converter groups. Each...... procedure is also described. The volume and the losses of the proposed solution are compared with that of the state-of-art solution. The control of the proposed converter system is also discussed. The analysis has been verified by the simulation and experimental results....

  20. 4 Channel Digital Down Converter – DDC (EDA-00991)

    CERN Document Server

    BLAS, A; DELONG, J (BNL)

    2012-01-01

    A novel rf beam control architecture has been successfully tested in the LEIR synchrotron. The design is based on a VME 64X carrier board, including a DSP (digital signal processor), into which different daughter cards can be plugged in. The DDC (Digital Down Converter) is one of them. Hardware wise it has the features of a four-channel ADC (analogue-to-digital converter) which outputs drive a powerful FPGA (field programmable logic array); the latter is connected to the DSP on the carrier board via high-speed connectors. Mainly, this unit will acquire rf signals to analyze their phase and amplitude at a specified harmonic of the revolution. The main sampling clock feeding the mezzanine board is at a high harmonic of the particle’s revolution frequency. In the PSB, this frequency is varying along the accelerating cycle and this choice allows analyzing the rf signals from the cavities or from the beam without changing any parameter along the cycle. The sampling clock is tagged at the revolution rate allowing...

  1. Mobile Internet Protocol Analysis

    National Research Council Canada - National Science Library

    Brachfeld, Lawrence

    1999-01-01

    ...) and User Datagram Protocol (UDP). Mobile IP allows mobile computers to send and receive packets addressed with their home network IP address, regardless of the IP address of their current point of attachment on the Internet...

  2. PI and Fuzzy Control Strategies for High Voltage Output DC-DC Boost Power Converter - Hardware Implementation and Analysis

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevi Kumar; Blaabjerg, Frede; Siano, Pierluigi

    2016-01-01

    This paper presents the control strategies by Proportional-Integral (P-I) and Fuzzy Logic (FL) for a DC-DC boost power converter for high output voltage configuration. Standard DC-DC converters are traditionally used for high voltage direct current (HVDC) power transmission systems. But, lack its...... converter with inbuilt voltage-lift technique and overcome the aforementioned deficiencies. Further, the control strategy is adapted based on proportional-integral (P-I) and fuzzy logic, closed-loop controller to regulate the outputs and ensure the performances. Complete hardware prototype of EHV converter...... performances in terms of efficiency, reduced transfer gain and increased cost with sensor units. Moreover, the internal self-parasitic components reduce the output voltage and efficiency of classical high voltage converters (HVC). This investigation focused on extra high-voltage (EHV) DC-DC boost power...

  3. Underwater Noise from a Wave Energy Converter Is Unlikely to Affect Marine Mammals.

    Science.gov (United States)

    Tougaard, Jakob

    2015-01-01

    Underwater noise was recorded from the Wavestar wave energy converter; a full-scale hydraulic point absorber, placed on a jack-up rig on the Danish North Sea coast. Noise was recorded 25 m from the converter with an autonomous recording unit (10 Hz to 20 kHz bandwidth). Median sound pressure levels (Leq) in third-octave bands during operation of the converter were 106-109 dB re. 1 μPa in the range 125-250 Hz, 1-2 dB above ambient noise levels (statistically significant). Outside the range 125-250 Hz the noise from the converter was undetectable above the ambient noise. During start and stop of the converter a more powerful tone at 150 Hz (sound pressure level (Leq) 121-125 dB re 1 μPa) was easily detectable. This tone likely originated from the hydraulic pump which was used to lower the absorbers into the water and lift them out of the water at shutdown. Noise levels from the operating wave converter were so low that they would barely be audible to marine mammals and the likelihood of negative impact from the noise appears minimal. A likely explanation for the low noise emissions is the construction of the converter where all moving parts, except for the absorbers themselves, are placed above water on a jack-up rig. The results may thus not be directly transferable to other wave converter designs but do demonstrate that it is possible to harness wave energy without noise pollution to the marine environment.

  4. Underwater Noise from a Wave Energy Converter Is Unlikely to Affect Marine Mammals.

    Directory of Open Access Journals (Sweden)

    Jakob Tougaard

    Full Text Available Underwater noise was recorded from the Wavestar wave energy converter; a full-scale hydraulic point absorber, placed on a jack-up rig on the Danish North Sea coast. Noise was recorded 25 m from the converter with an autonomous recording unit (10 Hz to 20 kHz bandwidth. Median sound pressure levels (Leq in third-octave bands during operation of the converter were 106-109 dB re. 1 μPa in the range 125-250 Hz, 1-2 dB above ambient noise levels (statistically significant. Outside the range 125-250 Hz the noise from the converter was undetectable above the ambient noise. During start and stop of the converter a more powerful tone at 150 Hz (sound pressure level (Leq 121-125 dB re 1 μPa was easily detectable. This tone likely originated from the hydraulic pump which was used to lower the absorbers into the water and lift them out of the water at shutdown. Noise levels from the operating wave converter were so low that they would barely be audible to marine mammals and the likelihood of negative impact from the noise appears minimal. A likely explanation for the low noise emissions is the construction of the converter where all moving parts, except for the absorbers themselves, are placed above water on a jack-up rig. The results may thus not be directly transferable to other wave converter designs but do demonstrate that it is possible to harness wave energy without noise pollution to the marine environment.

  5. Faults and Diagnosis Systems in Power Converters

    DEFF Research Database (Denmark)

    Lee, Kyo-Beum; Choi, Uimin

    2014-01-01

    A power converter is needed in almost all kinds of renewable energy systems and drive systems. It is used both for controlling the renewable source and for interfacing with the load, which can be grid-connected or working in standalone mode. Further, it drives the motors efficiently. Increasing...... efforts have been put into making these systems better in terms of reliability in order to achieve high power source availability, reduce the cost of energy and also increase the reliability of overall systems. Among the components used in power converters, a power device and a capacitor fault occurs most...... frequently. Therefore, it is important to monitor the power device and capacitor fault to increase the reliability of power electronics. In this chapter, the diagnosis methods for power device fault will be discussed by dividing into open- and short-circuit faults. Then, the condition monitoring methods...

  6. Strained quantum well photovoltaic energy converter

    Science.gov (United States)

    Freundlich, Alexandre (Inventor); Renaud, Philippe (Inventor); Vilela, Mauro Francisco (Inventor); Bensaoula, Abdelhak (Inventor)

    1998-01-01

    An indium phosphide photovoltaic cell is provided where one or more quantum wells are introduced between the conventional p-conductivity and n-conductivity indium phosphide layer. The approach allows the cell to convert the light over a wider range of wavelengths than a conventional single junction cell and in particular convert efficiently transparency losses of the indium phosphide conventional cell. The approach hence may be used to increase the cell current output. A method of fabrication of photovoltaic devices is provided where ternary InAsP and InGaAs alloys are used as well material in the quantum well region and results in an increase of the cell current output.

  7. Converter topologies for common mode voltage reduction

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Fernando

    2017-11-21

    An inverter includes a three-winding transformer, a DC-AC inverter electrically coupled to the first winding of the transformer, a cycloconverter electrically coupled to the second winding of the transformer, and an active filter electrically coupled to the third winding of the transformer. The DC-AC inverter is adapted to convert the input DC waveform to an AC waveform delivered to the transformer at the first winding. The cycloconverter is adapted to convert an AC waveform received at the second winding of the transformer to the output AC waveform having a grid frequency of the AC grid. The active filter is adapted to sink and source power with one or more energy storage devices based on a mismatch in power between the DC source and the AC grid. At least two of the DC-AC inverter, the cycloconverter, or the active filter are electrically coupled via a common reference electrical interconnect.

  8. Flower-petal mode converter for NLC

    International Nuclear Information System (INIS)

    Hoag, H.A.; Tantawi, S.G.; Callin, R.; Deruyter, H.; Farkas, Z.D.; Ko, K.; Kroll, N.; Lavine, T.L.; Menegat, A.; Vlieks, A.E.

    1993-01-01

    It is important to minimize power loss in the waveguide system connecting klystron, pulse-compressor, and accelerator in an X-Band NLC. However, existing designs of klystron output cavity circuits and accelerator input couplers utilize rectangular waveguide which has relatively high transmission loss. It is therefore necessary to convert to and from the low-loss mode in circulator waveguide at each end of the system. A description is given of development work on high-power, high-vacuum open-quote flower-petal close-quote transducers, which convert the TE 10 mode in rectangular guide to the TE 01 mode in circular guide. A three-port modification of the flower petal device, which can be used as either a power combiner at the klystron or a power divider at the accelerator is also described

  9. MAGIC: Model and Graphic Information Converter

    Science.gov (United States)

    Herbert, W. C.

    2009-01-01

    MAGIC is a software tool capable of converting highly detailed 3D models from an open, standard format, VRML 2.0/97, into the proprietary DTS file format used by the Torque Game Engine from GarageGames. MAGIC is used to convert 3D simulations from authoritative sources into the data needed to run the simulations in NASA's Distributed Observer Network. The Distributed Observer Network (DON) is a simulation presentation tool built by NASA to facilitate the simulation sharing requirements of the Data Presentation and Visualization effort within the Constellation Program. DON is built on top of the Torque Game Engine (TGE) and has chosen TGE's Dynamix Three Space (DTS) file format to represent 3D objects within simulations.

  10. Flower-petal mode converter for NLC

    International Nuclear Information System (INIS)

    Hoag, H.A.; Tantawi, S.G.; Callin, R.

    1993-04-01

    It is important to minimize power loss in the waveguide system connecting klystron, pulse-compressor, and accelerator in an X-Band NLC. However, existing designs of klystron output cavity circuits and accelerator input couplers utilize rectangular waveguide which has relatively high transmission loss. It is therefore necessary to convert to and from the low-loss mode in circular waveguide at each end of the system. A description is given of development work on high-power, high-vacuum 'flower-petal' transducers, which convert the TE 10 mode in rectangular guide to the TE 01 mode in circular guide. A three-port modification of the flower petal device, which can be used as either a power combiner at the klystron or a power divider at the accelerator is also described

  11. MOCCASIN: converting MATLAB ODE models to SBML.

    Science.gov (United States)

    Gómez, Harold F; Hucka, Michael; Keating, Sarah M; Nudelman, German; Iber, Dagmar; Sealfon, Stuart C

    2016-06-15

    MATLAB is popular in biological research for creating and simulating models that use ordinary differential equations (ODEs). However, sharing or using these models outside of MATLAB is often problematic. A community standard such as Systems Biology Markup Language (SBML) can serve as a neutral exchange format, but translating models from MATLAB to SBML can be challenging-especially for legacy models not written with translation in mind. We developed MOCCASIN (Model ODE Converter for Creating Automated SBML INteroperability) to help. MOCCASIN can convert ODE-based MATLAB models of biochemical reaction networks into the SBML format. MOCCASIN is available under the terms of the LGPL 2.1 license (http://www.gnu.org/licenses/lgpl-2.1.html). Source code, binaries and test cases can be freely obtained from https://github.com/sbmlteam/moccasin : mhucka@caltech.edu More information is available at https://github.com/sbmlteam/moccasin. © The Author 2016. Published by Oxford University Press.

  12. Boost Converter with Active Snubber Network

    Directory of Open Access Journals (Sweden)

    HIMMELSTOSS, F. A.

    2017-02-01

    Full Text Available A new concept for reducing the losses in a boost converter is described. With the help of an auxiliary switch and a resonant circuit, zero-voltage switching at turn-off and zero-current switching during turn-on are achieved. The modes of the circuit are shown in detail. The energy recovery of the turn-off is analyzed and the recovered energy is calculated; an optimized switching concept therefore is described. The influence of the parasitic capacity of the switch is discussed. Dimensioning hints for the converter and the design of the recuperation circuit are given. A bread-boarded design shows the functional efficiency of the concept.

  13. Terahertz broadband polarization converter based on metamaterials

    Science.gov (United States)

    Li, Yonghua; Zhao, Guozhong

    2018-01-01

    Based on the metamaterial composed of symmetrical split resonant ring, a broadband reflective terahertz polarization converter is proposed. The numerical simulation shows that it can rotate the polarization direction of linear polarized wave 90° in the range of 0.7-1.8THz and the polarization conversion ratio is over 90%. The reflection coefficient of the two electric field components in the diagonal direction is the same and the phase difference is 180° ,which leads to the cross-polarization rotation.In order to further study the physical mechanism of high polarization conversion, we analyze the surface current distribution of the resonant ring. The polarization converter has potential applications in terahertz wave plate and metamaterial antenna design.

  14. USA-USSR protocol

    CERN Multimedia

    1970-01-01

    On 30 November the USA Atomic Energy Commission and the USSR State Committee for the Utilization of Atomic Energy signed, in Washington, a protocol 'on carrying out of joint projects in the field of high energy physics at the accelerators of the National Accelerator Laboratory (Batavia) and the Institute for High Energy Physics (Serpukhov)'. The protocol will be in force for five years and can be extended by mutual agreement.

  15. A high efficiency photovoltaic module integrated converter with the asymmetrical half-bridge flyback converter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heeje; Kim, Jongrak; Shin, Dongsul [Department of Electrical Engineering, Pusan National University, Jangjeon, Geumjeong, Busan 609-735 (Korea); Kim, Hosung; Lee, Kyungjun [Department of Electrical Engineering, Pusan National University, Jangjeon, Geumjeong, Busan 609-735 (Korea); New and Renewable Energy System Research Center, Korea Electro-technology Research Institute, 28-1, Sungju-dong Changwon-si, Kyungsannam-do, 641-120 (Korea); Kim, Jonghyun; Yoo, Dongwook [New and Renewable Energy System Research Center, Korea Electro-technology Research Institute, 28-1, Sungju-dong Changwon-si, Kyungsannam-do, 641-120 (Korea)

    2010-08-15

    A module integrated converter (MIC) for a photovoltaic (PV) cell is important part of power conditioning system (PCS). It performs maximum power point tracking of a PV cell to generate the power as much as possible from solar energy. There are several methods for connection between the PV modules and the MICs. In order to avoid partial shading effects, converter-per-module approach was proposed. The MIC that performs maximum power point tracking (MPPT), if it is low efficiency, is no use. The MIC whose output is connected to the output of PV module was proposed for high efficiency. However, there are some problems. In this study, an asymmetrical half-bridge flyback converter is proposed instead of the original flyback converter with same method to solve the problems. The proposed MIC was built to verify the performance. The new topology using soft switching technique showed good performance for the efficiency. At the higher power, the efficiency of the proposed converter is higher than existing converter. (author)

  16. Method for Converter Synchronization with RF Injection

    OpenAIRE

    Joshua P. Bruckmeyer; Ivica Kostanic

    2015-01-01

    This paper presents an injection method for synchronizing analog to digital converters (ADC). This approach can eliminate the need for precision routed discrete synchronization signals of current technologies, such as JESD204. By eliminating the setup and hold time requirements at the conversion (or near conversion) clock rate, higher sample rate systems can be synchronized. Measured data from an existing multiple ADC conversion system was used to evaluate the method. Coherent beams were simu...

  17. Reversible thyristor converters of brushless synchronous compensators

    Directory of Open Access Journals (Sweden)

    А.М.Galynovskiy

    2013-12-01

    Full Text Available Behavior of models of three-phase-to-single-phase rotary reversible thyristor converters of brushless synchronous compensators in a circuit simulation system is analyzed. It is shown that combined control mode of opposite-connected thyristors may result in the exciter armature winding short circuits both at the thyristor feed-forward and lagging current delay angles. It must be taken into consideration when developing brushless compensator excitation systems.

  18. Characteristics of image converters and image intensifiers

    International Nuclear Information System (INIS)

    Gurvich, A.M.; Shamanov, A.A.; Rozenberg, A.M.; Fajnberg, V.S.; Kavtorova, V.P.; Salyuk, L.V.; Yakovleva, F.B.

    1978-01-01

    The characteristics of image converters and image intensifiers, which determine the range of the X-radiation dose rates used and the image quality, are considered. The equations for calculating the requirements to be imposed on the separate intensifier elements from known parameters of other elements with an allowance for the nonlinearity of the television system and the role of fluctuation in the space distribution of X-radiation quanta are given

  19. Seven channel gated charge to time converter

    Energy Technology Data Exchange (ETDEWEB)

    Stubbs, R J; Waddoup, W D [Durham Univ. (UK)

    1977-11-01

    By using a hybrid integrated circuit seven independent gated charge to time converters have been constructed in a single width NIM module. Gate widths from < approximately 10 ns to approximately 300 ns are possible with a resolution of 0.25 pC, linearity is better than +-1 pC over 2.5 decades of input signal height. Together with a multichannel scaling system described in the following paper one has a very powerful multichannel gated ADC system.

  20. Modeling the bremsstrahlung emission from converters

    CERN Document Server

    Mirea, M; Clapier, F; Hassaïne, M; Ibrahim, F; Müller, A C; Pauwels, N; Proust, J; Verney, D; Antoni, R; Bourgeois, L; Kandri-Rody, S

    2001-01-01

    The bremsstrahlung angular and energy theoretical distributions delivered from W and UCx thick converters are reported. This study is focussed on initial kinetic energies of the electron beam included in the range 30-60 MeV, suitable for the production of large radiative yields able to induce the $^{238}$U fission. These results offer the possibility to evaluate the required shielding for a neutron rich nuclei source.

  1. Combined analog-to-digital converter

    International Nuclear Information System (INIS)

    Zhukov, A.V.; Rzhendinskaya, S.N.

    1983-01-01

    A 10-bit analog-to-digital converter (ADC) designed for operating in spectrometers with time-dependent filters is described. The ADC operation is based on combining the parallel reading and sequential counting methods. At maximum conversion time of 12 μs, timing series frequency of 25 MHz and foUr reference levels the differential nonlinearity withoUt statistical smoothing (maximum relative channel width deviation from average value) is not more than 4%

  2. Environmental impact of Converted Electrical Motorcycle

    OpenAIRE

    Xuan, Pek Yang; Henz, Martin; Weigl, Joerg

    2013-01-01

    This study explores the environmental impact of the conversion of an internal combustion engine (ICE) sports motorcycle into a converted battery-powered electric vehicle (CBEV). Zero tailpipe emissions might lead to the assumption that such an ICE-to-BEV conversion will always yield net positive environmental benefits in life cycle greenhouse gas (GHG) emissions and energy reductions, but energy inputs and materials impacts associated with the conversion of a CBEV are weighed against savings ...

  3. Continuous process for converting hydrocarbons, etc

    Energy Technology Data Exchange (ETDEWEB)

    1934-05-01

    A continuous process is disclosed for converting hydrocarbons, liquid, semi-liquid, and solid, of all origins and kinds, into incondensable gases, without carbon deposits, characterized by the fact that an intimate mixture of the material and superheated steam before cracking is passed through a contact mass. The contact mass consists of all metals, metal alloys, and mineral salts which, at the reaction temperature, are fused and do not react with the water vapor or gaseous products.

  4. H- ion production from different converter materials

    International Nuclear Information System (INIS)

    Leung, K.N.; Ehlers, K.W.

    1984-10-01

    For heating plasmas and for current drive in some fusion reactors, high energy neutral beams may be required. The high neutralization efficiency of H - or D - ions makes them favorable to form neutral atoms with energies in excess of 160 keV. It has been shown that a steady-state H - ion beam with current greater than 1 A can be generated by a surface conversion type source with Mo being used as the converter material. In order to achieve the proper cesium coverage and thereby increasing the H - ion yield, the application of porous cesium-dispensing converters is being investigated. It is also possible to optimize the H - production by choosing the proper converter material. In this paper, we compare the negative ion yield generated by different materials (such as Mo, Ti, V, Nb, Pt, Pd, Rh, Cu, Ta, Al, Au, LaB 6 and stainless-steel) in the pure hydrogen and cesium-hydrogen modes of operation

  5. Converter fed sub sea motor drives

    Energy Technology Data Exchange (ETDEWEB)

    Raad, R O

    1995-09-01

    Minor offshore gas and oil resources located 20-50 km from existing installations may often be commercially exploited only by use of complete sub sea solutions. This thesis deals with analyses of a sub sea adjustable speed electric motor which is fed by a frequency converter via a long cable (up to 50 km) between the converter and the motor. The author develops a general model for analysing such motor drive systems with the objective of verifying the feasibility of specific applications and of specifying the requirements on the system components. The simulation model is used to identify the critical frequency ranges in which the converter must not generate significant harmonics, to verify the start-up strategy chosen, and to verify the stability with potential disturbances applied to the system. Simulation models are developed for both transient and steady state analyses. They are accurate up to 5 kHz and can incorporate the frequency dependency of the motor and cable parameters. Ideal thyristors and diodes are used. The models are implemented in existing simulation tools. Most of the results relate to a base case with a 670 kW squirrel cage motor fed from a 30 km long cable, but cases with 3 MW rating or with 50 km cable have also been analyzed and found to be feasible. Each specific application must be separately studied. Results of simulation calculations are presented and conclusions given. 53 refs., 124 figs., 23 tabs.

  6. Study on a Novel High-Efficiency Bridgeless PFC Converter

    Directory of Open Access Journals (Sweden)

    Cao Taiqiang

    2014-01-01

    Full Text Available In order to implement a high-efficiency bridgeless power factor correction converter, a new topology and operation principles of continuous conduction mode (CCM and DC steady-state character of the converter are analyzed, which show that the converter not only has bipolar-gain characteristic but also has the same characteristic as the traditional Boost converter, while the voltage transfer ratio is not related with the resonant branch parameters and switching frequency. Based on the above topology, a novel bridgeless Bipolar-Gain Pseudo-Boost PFC converter is proposed. With this converter, the diode rectifier bridge of traditional AC-DC converter is eliminated, and zero-current switching of fast recovery diode is achieved. Thus, the efficiency is improved. Next, we also propose the one-cycle control policy of this converter. Finally, experiments are provided to verify the accuracy and feasibility of the proposed converter.

  7. High-response intrauterine insemination cycles converted to low-cost in vitro fertilization

    Directory of Open Access Journals (Sweden)

    Aletebi F

    2011-05-01

    Full Text Available Fatma AletebiAssisted Reproduction Unit, Department of Obstetrics and Gynaecology, King Abdulaziz University, Soliman Fakeeh Hospital, Jeddah, Saudi ArabiaBackground: There is a trend to cancel intrauterine insemination (IUI in women with a high response. The aim of this study was to evaluate the efficacy of low-cost in vitro fertilization (IVF in high-response IUI cycles in comparison with conventional IVF.Methods and materials: A total of 46 women were included in the study. Group A (study group included 23 women with hyper-response to IUI cycles who were converted to IVF. They received oral letrozole 2.5 mg twice daily from days 3–7 of the menstrual cycle, along with 75 International Units (IU of recombinant follicle-stimulating hormone on days 3 and 8. Group B (control group underwent conventional IVF, and received downregulation with a gonadotrophin-releasing hormone agonist followed by stimulation with recombinant follicle-stimulating hormone 150–300 IU/day. Ovulation was triggered by 10,000 IU of human chorionic gonadotrophin, followed by IVF and embryo transfer. The primary outcome measure analyzed was pregnancy rates in both groups.Results: The study group received a significantly lower (P = 0.001 total dose of follicle-stimulating hormone and had significantly (P = 0.002 decreased levels of terminal estradiol. Although the pregnancy rate (30.43% in the study group versus 39.13% in the conventional group per stimulated cycle was higher in the conventional IVF group, the miscarriage rate (study group 4.34% versus conventional group 13.04% was also higher, and hence the take-home baby rate (study group 26.08% versus conventional group 30.43% was more or less similar in both the groups.Conclusion: IVF can be offered to women having a high response to IUI cycles with good pregnancy rates and at low cost compared with use of a conventional protocol, and therefore can be considered more patient-friendly in selected cases.Keywords: low

  8. Antenna unit and radio base station therewith

    Science.gov (United States)

    Kuwahara, Mikio; Doi, Nobukazu; Suzuki, Toshiro; Ishida, Yuji; Inoue, Takashi; Niida, Sumaru

    2007-04-10

    Phase and amplitude deviations, which are generated, for example, by cables connecting an array antenna of a CDMA base station and the base station, are calibrated in the baseband. The base station comprises: an antenna apparatus 1; couplers 2; an RF unit 3 that converts a receive signal to a baseband signal, converts a transmit signal to a radio frequency, and performs power control; an A/D converter 4 for converting a receive signal to a digital signal; a receive beam form unit 6 that multiplies the receive signal by semi-fixed weight; a despreader 7 for this signal input; a time-space demodulator 8 for demodulating user data; a despreader 9 for probe signal; a space modulator 14 for user data; a spreader 13 for user signal; a channel combiner 12; a Tx calibrater 11 for controlling calibration of a signal; a D/A converter 10; a unit 16 for calculation of correlation matrix for generating a probe signal used for controlling an Rx calibration system and a TX calibration system; a spreader 17 for probe signal; a power control unit 18; a D/A converter 19; an RF unit 20 for probe signal; an A/D converter 21 for signal from the couplers 2; and a despreader 22.

  9. Hydrodynamic Characteristics and Strength Analysis of a Novel Dot-matrix Oscillating Wave Energy Converter

    Science.gov (United States)

    Shao, Meng; Xiao, Chengsi; Sun, Jinwei; Shao, Zhuxiao; Zheng, Qiuhong

    2017-12-01

    The paper analyzes hydrodynamic characteristics and the strength of a novel dot-matrix oscillating wave energy converter, which is in accordance with nowadays’ research tendency: high power, high efficiency, high reliability and low cost. Based on three-dimensional potential flow theory, the paper establishes motion control equations of the wave energy converter unit and calculates wave loads and motions. On this basis, a three-dimensional finite element model of the device is built to check its strength. Through the analysis, it can be confirmed that the WEC is feasible and the research results could be a reference for wave energy’s exploration and utilization.

  10. A novel double quad-inverter configuration for multilevel twelve-phase open-winding converter

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevi Kumar; Blaabjerg, Frede; Wheeler, Patrick William

    2016-01-01

    This paper describes a novel proposal of double quad-inverter configuration for multilevel twelve-phase open-winding ac converter. Modular power units are developed from reconfigured eight classical three-phase voltage source inverters (VSIs). Each VSI has one additional bi-directional switching...... numerical simulation software's (Matlab/PLECS) developments. Further, the results confirm the good agreement to the developed theoretical background. Proposed converter suits the need of low-voltage/high-current applications such as ac tractions and `More-Electric Aircraft' propulsion systems....

  11. Hexuple-Inverter Configuration for Multilevel Nine-Phase Symmetrical Open-Winding Converter

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevi Kumar; Bhaskar, Mahajan Sagar; Maroti, Pandav Kiran

    2016-01-01

    Hexuple-inverter configuration for multilevel nine-phase symmetrical open-winding ac converter is articulated in this work. Power modular unit consists of six classical three-phase voltage source inverters (VSI). Each VSI includes one bi-directional device (MOSFET/IGBT) per each phase and link...... software’s (Matlab/PLECS). Results always showed good conformity with the developed theoretical background under working conditions. The proposed converter found suit for (low-voltage/high current) electric vehicles, ac tractions and ‘More-Electric Aircraft’ applications....

  12. Analysis and control of a hybrid vehicle powered by free-piston energy converter

    OpenAIRE

    Hansson, Jörgen

    2006-01-01

    The introduction of hybrid powertrains has made it possible to utilise unconventional engines as primary power units in vehicles. The free-piston energy converter (FPEC) is such an engine. It is a combination of a free-piston combustion engine and a linear electrical machine. The main features of this configuration are high efficiency and a rapid transient response. In this thesis the free-piston energy converter as part of a hybrid powertrain is studied. One issue of the FPEC is the generati...

  13. Is a New Protocol for Acute Lymphoblastic Leukemia Research or Standard Therapy?

    NARCIS (Netherlands)

    Dekking, SAS; van der Graaf, R; de Vries, Martine; Bierings, MB; van Delden, JJM; Kodish, Eric; Lantos, John

    2015-01-01

    In the United States, doctors generally develop new cancer chemotherapy for children by testing innovative chemotherapy protocols against existing protocols in prospective randomized trials. In the Netherlands, children with leukemia are treated by protocols that are agreed upon by the Dutch

  14. Fault isolation in parallel coupled wind turbine converters

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Thøgersen, Paul Bach; Stoustrup, Jakob

    2010-01-01

    Parallel converters in wind turbine give a number advantages, such as fault tolerance due to the redundant converters. However, it might be difficult to isolate gain faults in one of the converters if only a combined power measurement is available. In this paper a scheme using orthogonal power...... references to the converters is proposed. Simulations on a wind turbine with 5 parallel converters show a clear potential of this scheme for isolation of this gain fault to the correct converter in which the fault occurs....

  15. Novel screening techniques for wind turbine power converters

    DEFF Research Database (Denmark)

    Jørgensen, Asger Bjørn; Sønderskov, Simon Dyhr; Christensen, Nicklas

    2016-01-01

    Power converters represent one of the highest failure rates in the wind turbine. Therefore converter manufacturers perform burn-in tests to prevent shipping of faulty converters. Recent developments in junction temperature estimation, based on accurate online IGBT collector-emitter voltage...... measurements, allow for thermal stress estimation of the IGBT modules. This is utilized to detect infant mortalities in power converters, by comparing thermal responses of IGBTs for faulty and non-faulty converters. The method proves to be a time and cost efficient candidate to replace burn-in tests of power...... converters for wind turbines applications....

  16. Impedance coordinative control for cascaded converter in bidirectional application

    DEFF Research Database (Denmark)

    Tian, Yanjun; Loh, Poh Chiang; Deng, Fujin

    2016-01-01

    A two-stage cascaded converter is formed by connecting two sub-converters in series. Output impedance of one sub-converter will therefore interact with input impedance of the other sub-converter. Such interaction may affect the system dynamics and stability, especially when one sub......-converter is constant-power-controlled, and hence has different impedance characteristics when its power reverses. To lessen such constant-power effects, a control scheme that can coordinate impedance behaviors of the two sub-converters is proposed. The idea is to reshape the lowfrequency negative impedance...

  17. A resonant dc-dc power converter assembly

    OpenAIRE

    Madsen, Mickey Pierre

    2015-01-01

    The present invention relates to a resonant DC-DC power converter assembly comprising a first resonant DC-DC power converter and a second resonant DC-DC power converter having identical circuit topologies. A first inductor of the first resonant DC-DC power converter and a second inductor of the second resonant DC-DC power converter are configured for magnetically coupling the first and second resonant DC-DC power converters to each other to forcing substantially 180 degrees phase shift, or fo...

  18. One-Quadrant Switched-Mode Power Converters

    CERN Document Server

    Petrocelli, R.

    2015-06-15

    This article presents the main topics related to one-quadrant power convert- ers. The basic topologies are analysed and a simple methodology to obtain the steady-state output–input voltage ratio is set out. A short discussion of dif- ferent methods to control one-quadrant power converters is presented. Some of the reported derived topologies of one-quadrant power converters are also considered. Some topics related to one-quadrant power converters such as syn- chronous rectification, hard and soft commutation, and interleaved converters are discussed. Finally, a brief introduction to resonant converters is given.

  19. Will OPEC lose from the Kyoto Protocol?

    International Nuclear Information System (INIS)

    Barnett, Jon; Dessai, Suraje; Webber, Michael

    2004-01-01

    A range of energy-economy models forecast losses to members of the Organisation of Petroleum Exporting Countries (OPEC) should the Kyoto Protocol come into force. These forecasts are a powerful influence in the United Nations Framework Convention on Climate Change negotiations. They are used by OPEC to advance the agenda on the impacts of response measures, covertly arguing for compensation for lost oil revenues arising from implementation of the Protocol. This paper discusses this issue, and explores the key assumptions of these models and their uncertainties. Assumptions about carbon leakage, future availability of oil reserves, substitution, innovation, and capital turnover are considered. The paper suggests that losses will not affect OPEC countries equally, and that these losses are not likely to be as substantial as the models forecast. A range of policy measures are proposed to lessen any impact the Protocol may have on OPEC

  20. High frequency Soft Switching Half Bridge Series-Resonant DC-DC Converter Utilizing Gallium Nitride FETs

    DEFF Research Database (Denmark)

    Nour, Yasser; Knott, Arnold; Petersen, Lars Press

    2017-01-01

    The need for efficient, smaller, lighter and cheaper power supply units drive the investigation of using high switching frequency soft switching resonant converters. This work presents an 88% efficient 48V nominal input converter switching at 6 MHz and output power of 21 Watts achieving power...... density of 7 W/cm3 for Power-over-Ethernet LED lighting applications. The switching frequency is used to control the output current delivered to the load resistance. The converter was tested using a constant resistance load. The performance and thermal behavior were investigated and reported in this work....

  1. Modulation and control of matrix converter for aerospace application

    Science.gov (United States)

    Kobravi, Keyhan

    In the context of modern aircraft systems, a major challenge is power conversion to supply the aircraft's electrical instruments. These instruments are energized through a fixed-frequency internal power grid. In an aircraft, the available sources of energy are a set of variable-speed generators which provide variable-frequency ac voltages. Therefore, to energize the internal power grid of an aircraft, the variable-frequency ac voltages should be converted to a fixed-frequency ac voltage. As a result, an ac to ac power conversion is required within an aircraft's power system. This thesis develops a Matrix Converter to energize the aircraft's internal power grid. The Matrix Converter provides a direct ac to ac power conversion. A major challenge of designing Matrix Converters for aerospace applications is to minimize the volume and weight of the converter. These parameters are minimized by increasing the switching frequency of the converter. To design a Matrix Converter operating at a high switching frequency, this thesis (i) develops a scheme to integrate fast semiconductor switches within the current available Matrix Converter topologies, i.e., MOSFET-based Matrix Converter, and (ii) develops a new modulation strategy for the Matrix Converter. This Matrix Converter and the new modulation strategy enables the operation of the converter at a switching-frequency of 40kHz. To provide a reliable source of energy, this thesis also develops a new methodology for robust control of Matrix Converter. To verify the performance of the proposed MOSFET-based Matrix Converter, modulation strategy, and control design methodology, various simulation and experimental results are presented. The experimental results are obtained under operating condition present in an aircraft. The experimental results verify the proposed Matrix Converter provides a reliable power conversion in an aircraft under extreme operating conditions. The results prove the superiority of the proposed Matrix

  2. In silico toxicology protocols.

    Science.gov (United States)

    Myatt, Glenn J; Ahlberg, Ernst; Akahori, Yumi; Allen, David; Amberg, Alexander; Anger, Lennart T; Aptula, Aynur; Auerbach, Scott; Beilke, Lisa; Bellion, Phillip; Benigni, Romualdo; Bercu, Joel; Booth, Ewan D; Bower, Dave; Brigo, Alessandro; Burden, Natalie; Cammerer, Zoryana; Cronin, Mark T D; Cross, Kevin P; Custer, Laura; Dettwiler, Magdalena; Dobo, Krista; Ford, Kevin A; Fortin, Marie C; Gad-McDonald, Samantha E; Gellatly, Nichola; Gervais, Véronique; Glover, Kyle P; Glowienke, Susanne; Van Gompel, Jacky; Gutsell, Steve; Hardy, Barry; Harvey, James S; Hillegass, Jedd; Honma, Masamitsu; Hsieh, Jui-Hua; Hsu, Chia-Wen; Hughes, Kathy; Johnson, Candice; Jolly, Robert; Jones, David; Kemper, Ray; Kenyon, Michelle O; Kim, Marlene T; Kruhlak, Naomi L; Kulkarni, Sunil A; Kümmerer, Klaus; Leavitt, Penny; Majer, Bernhard; Masten, Scott; Miller, Scott; Moser, Janet; Mumtaz, Moiz; Muster, Wolfgang; Neilson, Louise; Oprea, Tudor I; Patlewicz, Grace; Paulino, Alexandre; Lo Piparo, Elena; Powley, Mark; Quigley, Donald P; Reddy, M Vijayaraj; Richarz, Andrea-Nicole; Ruiz, Patricia; Schilter, Benoit; Serafimova, Rositsa; Simpson, Wendy; Stavitskaya, Lidiya; Stidl, Reinhard; Suarez-Rodriguez, Diana; Szabo, David T; Teasdale, Andrew; Trejo-Martin, Alejandra; Valentin, Jean-Pierre; Vuorinen, Anna; Wall, Brian A; Watts, Pete; White, Angela T; Wichard, Joerg; Witt, Kristine L; Woolley, Adam; Woolley, David; Zwickl, Craig; Hasselgren, Catrin

    2018-04-17

    The present publication surveys several applications of in silico (i.e., computational) toxicology approaches across different industries and institutions. It highlights the need to develop standardized protocols when conducting toxicity-related predictions. This contribution articulates the information needed for protocols to support in silico predictions for major toxicological endpoints of concern (e.g., genetic toxicity, carcinogenicity, acute toxicity, reproductive toxicity, developmental toxicity) across several industries and regulatory bodies. Such novel in silico toxicology (IST) protocols, when fully developed and implemented, will ensure in silico toxicological assessments are performed and evaluated in a consistent, reproducible, and well-documented manner across industries and regulatory bodies to support wider uptake and acceptance of the approaches. The development of IST protocols is an initiative developed through a collaboration among an international consortium to reflect the state-of-the-art in in silico toxicology for hazard identification and characterization. A general outline for describing the development of such protocols is included and it is based on in silico predictions and/or available experimental data for a defined series of relevant toxicological effects or mechanisms. The publication presents a novel approach for determining the reliability of in silico predictions alongside experimental data. In addition, we discuss how to determine the level of confidence in the assessment based on the relevance and reliability of the information. Copyright © 2018. Published by Elsevier Inc.

  3. A Simulation-Based Evaluation of Premovement Active Surveillance Protocol Options for the Managed Movement of Turkeys to Slaughter During an Outbreak of Highly Pathogenic Avian Influenza in the United States.

    Science.gov (United States)

    Todd Weaver, J; Malladi, Sasidhar; Bonney, Peter J; Patyk, Kelly A; Bergeron, Justin G; Middleton, Jamie L; Alexander, Catherine Y; Goldsmith, Timothy J; Halvorson, David A

    2016-05-01

    Risk management decisions associated with live poultry movement during a highly pathogenic avian influenza (HPAI) outbreak should be carefully considered. Live turkey movements may pose a risk for disease spread. On the other hand, interruptions in scheduled movements can disrupt business continuity. The Secure Turkey Supply (STS) Plan was developed through an industry-government-academic collaboration to address business continuity concerns that might arise during a HPAI outbreak. STS stakeholders proposed outbreak response measure options that were evaluated through risk assessment. The developed approach relies on 1) diagnostic testing of two pooled samples of swabs taken from dead turkeys immediately before movement via the influenza A matrix gene real-time reverse transcriptase polymerase chain reaction (rRT-PCR) test; 2) enhanced biosecurity measures in combination with a premovement isolation period (PMIP), restricting movement onto the premises for a few days before movement to slaughter; and 3) incorporation of a distance factor from known infected flocks such that exposure via local area spread is unlikely. Daily exposure likelihood estimates from spatial kernels from past HPAI outbreaks were coupled with simulation models of disease spread and active surveillance to evaluate active surveillance protocol options that differ with respect to the number of swabs per pooled sample and the timing of the tests in relation to movement. Simulation model results indicate that active surveillance testing, in combination with strict biosecurity, substantially increased HPAI virus detection probability. When distance from a known infected flock was considered, the overall combined likelihood of moving an infected, undetected turkey flock to slaughter was predicted to be lower at 3 and 5 km. The analysis of different active surveillance protocol options is designed to incorporate flexibility into HPAI emergency response plans.

  4. Fetal MRI: techniques and protocols

    International Nuclear Information System (INIS)

    Prayer, Daniela; Brugger, Peter Christian; Prayer, Lucas

    2004-01-01

    The development of ultrafast sequences has led to a significant improvement in fetal MRI. Imaging protocols have to be adjusted to the rapidly developing fetal central nervous system (CNS) and to the clinical question. Sequence parameters must be changed to cope with the respective developmental stage, to produce images free from motion artefacts and to provide optimum visualization of the region and focus of interest. In contrast to postnatal studies, every suspect fetal CNS abnormality requires examination of the whole fetus and the extrafetal intrauterine structures including the uterus. This approach covers both aspects of fetal CNS disorders: isolated and complex malformations and cerebral lesions arising from the impaired integrity of the feto-placental unit. (orig.)

  5. Fetal MRI: techniques and protocols

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, Daniela [Department of Neuroradiology, University Clinics of Radiodiagnostics, Medical University Vienna, Waehringerguertel 18-10, 1090, Vienna (Austria); Brugger, Peter Christian [Department of Anatomy, Integrative Morphology Group, Medical University Vienna (Austria); Prayer, Lucas [Diagnosezentrum Urania, Vienna (Austria)

    2004-09-01

    The development of ultrafast sequences has led to a significant improvement in fetal MRI. Imaging protocols have to be adjusted to the rapidly developing fetal central nervous system (CNS) and to the clinical question. Sequence parameters must be changed to cope with the respective developmental stage, to produce images free from motion artefacts and to provide optimum visualization of the region and focus of interest. In contrast to postnatal studies, every suspect fetal CNS abnormality requires examination of the whole fetus and the extrafetal intrauterine structures including the uterus. This approach covers both aspects of fetal CNS disorders: isolated and complex malformations and cerebral lesions arising from the impaired integrity of the feto-placental unit. (orig.)

  6. High power density dc/dc converter: Selection of converter topology

    Science.gov (United States)

    Divan, Deepakraj M.

    1990-01-01

    The work involved in the identification and selection of a suitable converter topology is described. Three new dc/dc converter topologies are proposed: Phase-Shifted Single Active Bridge DC/DC Converter; Single Phase Dual Active Bridges DC/DC Converter; and Three Phase Dual Active Bridges DC/DC Converter (Topology C). The salient features of these topologies are: (1) All are minimal in structure, i.e., each consists of an input and output bridge, input and output filter and a transformer, all components essential for a high power dc/dc conversion process; (2) All devices of both the bridges can operate under near zero-voltage conditions, making possible a reduction of device switching losses and hence, an increase in switching frequency; (3) All circuits operate at a constant frequency, thus simplifying the task of the magnetic and filter elements; (4) Since, the leakage inductance of the transformer is used as the main current transfer element, problems associated with the diode reverse recovery are eliminated. Also, this mode of operation allows easy paralleling of multiple modules for extending the power capacity of the system; (5) All circuits are least sensitive to parasitic impedances, infact the parasitics are efficently utilized; and (6) The soft switching transitions, result in low electromagnetic interference. A detailed analysis of each topology was carried out. Based on the analysis, the various device and component ratings for each topology operating at an optimum point, and under the given specifications, are tabulated and discussed.

  7. High Current, Low Voltage Power Converter [20kA, 6V] LHC Converter Prototype

    CERN Document Server

    Jørgensen, H E; Dupaquier, A; Fernqvist, G

    1998-01-01

    The superconducting LHC accelerator requires high currents (~12.5kA) and relatively low voltages (~10 V) for its magnets. The need to install the power converters underground is the driving force for reduced volume and high efficiency. Moreover, the LHC machine will require a very high level of performance from the power converters, particularly in terms of DC stability, dynamic response and also in matters of EMC. To meet these requirements soft-switching techniques will be used. This paper describes the development of a [20kA,6V] power converter intended as a stable high-current source for D CCT calibration and an evaluation prototype for the future LHC converters. The converter is made with a modular concept with five current sources [4kA,6V] in parallel. The 4kA sources are built as plu g-in modules: a diode rectifier on the AC mains with a damped L-C passive filter, a Zero Voltage Switching inverter working at 20 kHz and an output stage (high frequency transformers, Schottky rectifi ers and output filter...

  8. Business protocol in integrated Europe

    OpenAIRE

    Pavelová, Nina

    2009-01-01

    The first chapter devotes to definitions of basic terms such as protocol or business protocol, to differences between protocol and etiquette, and between social etiquette and business etiquette. The second chapter focuses on the factors influencing the European business protocol. The third chapter is devoted to the etiquette of business protocol in the European countries. It touches the topics such as punctuality and planning of business appointment, greeting, business cards, dress and appear...

  9. Security Protocols in a Nutshell

    OpenAIRE

    Toorani, Mohsen

    2016-01-01

    Security protocols are building blocks in secure communications. They deploy some security mechanisms to provide certain security services. Security protocols are considered abstract when analyzed, but they can have extra vulnerabilities when implemented. This manuscript provides a holistic study on security protocols. It reviews foundations of security protocols, taxonomy of attacks on security protocols and their implementations, and different methods and models for security analysis of pro...

  10. A universal quantum frequency converter via four-wave-mixing processes

    Science.gov (United States)

    Cheng, Mingfei; Fang, Jinghuai

    2016-06-01

    We present a convenient and flexible way to realize a universal quantum frequency converter by using nondegenerate four-wave-mixing processes in the ladder-type three-level atomic system. It is shown that quantum state exchange between two fields with large frequency difference can be readily achieved, where one corresponds to the atomic resonant transition in the visible spectral region for quantum memory and the other to the telecommunication range wavelength (1550 nm) for long-distance transmission over optical fiber. This method would bring great facility in realistic quantum information processing protocols with atomic ensembles as quantum memory and low-loss optical fiber as transmission channel.

  11. A THREE-PHASE BOOST DC-AC CONVERTER

    African Journals Online (AJOL)

    dc-ac converter (inverter) based on the dc-dc boost converters. ... Sliding mode controllers are designed to perform a robust control for the ... Computer simulations and spectral analysis demon- ... the conventional three-phase buck inverter,.

  12. Performance Evaluation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Pecher, Arthur

    . Guidelines for the development of wave energy converters recommend the use of different prototypes, having different sizes, which have to perform tank tests or sea trials. This implicates the need of different testing environment, which shifts from being controllable to uncontrollable with the development......, with more than 150 concepts currently being developed worldwide. Wave energy conversion concepts can be of many kinds, as the energy in the waves can be absorbed in many different ways. However, each concept is expected to require a thorough development process, involving different phases and prototypes...

  13. Layout Optimisation of Wave Energy Converter Arrays

    DEFF Research Database (Denmark)

    Ruiz, Pau Mercadé; Nava, Vincenzo; Topper, Mathew B. R.

    2017-01-01

    This paper proposes an optimisation strategy for the layout design of wave energy converter (WEC) arrays. Optimal layouts are sought so as to maximise the absorbed power given a minimum q-factor, the minimum distance between WECs, and an area of deployment. To guarantee an efficient optimisation......, a four-parameter layout description is proposed. Three different optimisation algorithms are further compared in terms of performance and computational cost. These are the covariance matrix adaptation evolution strategy (CMA), a genetic algorithm (GA) and the glowworm swarm optimisation (GSO) algorithm...

  14. Waste Plastic Converting into Hydrocarbon Fuel Materials

    Energy Technology Data Exchange (ETDEWEB)

    Sarker, Moinuddin; Mamunor Rashid, Mohammad; Molla, Mohammad

    2010-09-15

    The increased demand and high prices for energy sources are driving efforts to convert organic compounds into useful hydrocarbon fuels. Although much of this work has focused on biomass, there are strong benefits to deriving fuels from waste plastic material. Natural State Research Inc. (NSR) has invented a simple and economically viable process to decompose the hydrocarbon polymers of waste plastic into the shorter chain hydrocarbon of liquid fuel (patent pending). The method and principle of the production / process will be discussed. Initial tests with several widely used polymers indicate a high potential for commercialization.

  15. Aquabuoy Wave Energy Converter

    DEFF Research Database (Denmark)

    Vicinanza, Diego; Margheritini, Lucia; Frigaard, Peter

    The work reported here is part of the contract agreement between the Finavera Renewables Ocean Energy Ltd. and the Department of Civil Engineering Hydraulics and Coastal Engineering Laboratory to instrument a model in scale 1:10 to prototype of the AquaBuOY (AB) wave energy converter and to analyse...... its performances in real sea testing in Nissum Bredning, Denmark. This report is part of Fineveras contribution to ForskEl project no 6435 “AquaBuOY skala 1:10 forsøg I Nissum Bredning”....

  16. Power converters for medium voltage networks

    CERN Document Server

    Islam, Md Rabiul; Zhu, Jianguo

    2014-01-01

    This book examines a number of topics, mainly in connection with advances in semiconductor devices and magnetic materials and developments in medium and large-scale renewable power plant technologies, grid integration techniques and new converter topologies, including advanced digital control systems for medium-voltage networks. The book's individual chapters provide an extensive compilation of fundamental theories and in-depth information on current research and development trends, while also exploring new approaches to overcoming some critical limitations of conventional grid integration te

  17. Design, modeling and testing of data converters

    CERN Document Server

    Kiaei, Sayfe; Xu, Fang

    2014-01-01

    This book presents the a scientific discussion of the state-of-the-art techniques and designs for modeling, testing and for the performance analysis of data converters. The focus is put on sustainable data conversion. Sustainability has become a public issue that industries and users can not ignore. Devising environmentally friendly solutions for data conversion designing, modeling and testing is nowadays a requirement that researchers and practitioners must consider in their activities. This book presents the outcome of the IWADC workshop 2011, held in Orvieto, Italy.

  18. Near-Shore Floating Wave Energy Converters

    DEFF Research Database (Denmark)

    Ruol, Piero; Zanuttigh, Barbara; Martinelli, Luca

    2011-01-01

    and transmission characteristics are approximated to functions of wave height, period and obliquity. Their order of magnitude are 20% and 80%, respectively. It is imagined that an array of DEXA is deployed in front of Marina di Ravenna beach (IT), a highly touristic site of the Adriatic Coast. Based on the CERC......Aim of this note is to analyse the possible application of a Wave Energy Converter (WEC) as a combined tool to protect the coast and harvest energy. Physical model tests are used to evaluate wave transmission past a near-shore floating WEC of the wave activated body type, named DEXA. Efficiency...

  19. Analysis of serum angiotensin-converting enzyme.

    Science.gov (United States)

    Muller, B R

    2002-09-01

    Serum angiotensin-converting enzyme (SACE) levels are influenced by genetic polymorphism. Interpretation of serum levels with the appropriate genotypic reference range improves the diagnostic sensitivity of the assay for sarcoidosis. SACE assays are performed by a large number of routine clinical laboratories. However, there is no external quality assessment (EQA) for SACE other than an informal regional scheme. This showed analytical performance of SACE assays to be poor, with a diversity of reference ranges, leading to widely disparate clinical classification of EQA samples. Genetic polymorphism combined with poor analytical performance suggest that perhaps SACE assays should revert to being the province of specialized laboratories.

  20. DNA repair protocols

    DEFF Research Database (Denmark)

    Bjergbæk, Lotte

    In its 3rd edition, this Methods in Molecular Biology(TM) book covers the eukaryotic response to genomic insult including advanced protocols and standard techniques in the field of DNA repair. Offers expert guidance for DNA repair, recombination, and replication. Current knowledge of the mechanisms...... that regulate DNA repair has grown significantly over the past years with technology advances such as RNA interference, advanced proteomics and microscopy as well as high throughput screens. The third edition of DNA Repair Protocols covers various aspects of the eukaryotic response to genomic insult including...... recent advanced protocols as well as standard techniques used in the field of DNA repair. Both mammalian and non-mammalian model organisms are covered in the book, and many of the techniques can be applied with only minor modifications to other systems than the one described. Written in the highly...

  1. Intestinal fatty acid binding protein as a marker for intra-abdominal pressure-related complications in patients admitted to the intensive care unit; study protocol for a prospective cohort study (I-Fabulous study)

    NARCIS (Netherlands)

    K.D. Strang; O.J.F. van Waes (Oscar); B. van der Hoven (Ben); S. Ali (Samir); M.H.J. Verhofstad (Michiel); P. Pickkers (Peter); E.M.M. van Lieshout (Esther)

    2015-01-01

    textabstractBackground: Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) have detrimental effects on all organ systems and are associated with increased morbidity and mortality in critically ill patients admitted to an intensive care unit. Intra-bladder measurement of the

  2. Intestinal fatty acid binding protein as a marker for intra-abdominal pressure-related complications in patients admitted to the intensive care unit; study protocol for a prospective cohort study (I-Fabulous study)

    NARCIS (Netherlands)

    Strang, S.G.; Waes, O.J. van; Hoven, B. van der; Ali, S.; Verhofstad, M.H.J.; Pickkers, P.; Lieshout, E.M. van

    2015-01-01

    BACKGROUND: Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) have detrimental effects on all organ systems and are associated with increased morbidity and mortality in critically ill patients admitted to an intensive care unit. Intra-bladder measurement of the

  3. Matrix converter applied to energy saving for street lighting systems

    OpenAIRE

    Román Lumbreras, Manuel; Velasco Quesada, Guillermo; Conesa Roca, Alfons

    2010-01-01

    This work presents a three-phase AC-AC converter, with independent phase control, based on matrix-converter structure. This converter is applied to electrical energy saving on the public lighting systems by means of regulation and control of the voltage applied to the lamps. The developed converter represents a technological improvement with respect to the traditional systems based on an autotransformer: it reduces system cost and volume, and increases lamps lifetime.

  4. Generalized model of a bidirectional DC-DC converter

    Science.gov (United States)

    Hinov, Nikolay; Arnaudov, Dimitar; Penev, Dimitar

    2017-12-01

    The following paperwork presents models of bidirectional converters. A classic bidirectional converter and a new bidirectional circuit based on a ZCS resonant converter are investigated and compared. The developed models of these converters allow comparison between their characteristics showing their advantages and disadvantages. The models allow precise models of energy storage elements to be implemented as well, which is useful for examination of energy storage systems.

  5. Three-phase Resonant DC-link Converter

    OpenAIRE

    Munk-Nielsen, Stig

    1997-01-01

    The purpose of the project is to develop a three-phase resonant converter suitable for standard speed drives. The motivation for working with resonant converters is found in the problem of the standard converter type used today. In standard converter type Pulse Width Modulated-Voltage Source Inverter, PWM-VSI, the switches are subject to high current and voltage stress during switching, which causes losses. The fast switching of modern switches reduces switching losses. Unfortunately this pro...

  6. Unregulated Series Resonant Converter for Interlinking DC Nanogrids

    DEFF Research Database (Denmark)

    Tomas Manez, Kevin; Zhang, Zhe; Ouyang, Ziwei

    2017-01-01

    bidirectional converter to interlink a 400V DC bus with a 48V DC bus ispresented. The proposed converter is based on a LLC resonant converter operating as a DC transformer at a fixed frequency and duty cycle without any complex control strategy. A clearand simplified design procedure for high efficiency...

  7. Alternative Fuels Data Center: Landfills Convert Biogas Into Renewable

    Science.gov (United States)

    Natural Gas Landfills Convert Biogas Into Renewable Natural Gas to someone by E-mail Share Alternative Fuels Data Center: Landfills Convert Biogas Into Renewable Natural Gas on Facebook Tweet about Alternative Fuels Data Center: Landfills Convert Biogas Into Renewable Natural Gas on Twitter Bookmark

  8. Multistage switched inductor boost converter for renewable energy application

    DEFF Research Database (Denmark)

    Maroti, Pandav Kiran; Padmanaban, Sanjeevikumar; Bhaskar, Mahajan Sagar

    2017-01-01

    In this paper Multistage Switched Inductor Boost Converter (Multistage SIBC) is uttered for renewable energy applications. The projected converter is derived from an amalgamation of the conventional step-up converter and inductor stack. The number of inductor and duty ratio decides the overall...

  9. Sheppard-Taylor Isolated High Boost DC-DC Converter

    DEFF Research Database (Denmark)

    Chub, Andrii; Siwakoti, Yam Prasad; Vinnikov, Dmitri

    2017-01-01

    This paper presents a new galvanically isolated step-up dc-dc converter intended for low-power but high step-up applications. The proposed converter is capable of regulating output voltage within a wide range of the input voltage or load variations. In contrast to competitors, the converter can...

  10. Calculation of spatial distribution of the EURACOS II converter source

    International Nuclear Information System (INIS)

    Santo, A.C.F. de

    1985-01-01

    It is obtained the neutron spatial flux from the EURACOS (Enriched Uranium Converter Source) device, adjusted to experimental measures. The EURACOS device is a converter source which is constituted a circle plate of highly enriched uranium (90%). The converter provides an intense source of fast neutrons which has the energetic spectrum near to the fission spectrum. (M.C.K.) [pt

  11. Efficiency and reliability improvement in wind turbine converters by grid converter adaptive control

    DEFF Research Database (Denmark)

    Trintis, Ionut; Munk-Nielsen, Stig; Abrahamsen, Flemming

    2013-01-01

    This paper presents a control method that reduces the losses in wind turbine converters adaptively controlling the grid converter. The dc-link voltage adapts its reference based on the system state and therefore reduces the stored energy, and is therefore kept at the minimum necessary for the grid...... and generator side. Operating in this way, the electrical and thermal stress factors are decreased on the power electronic devices, increasing their lifetime. The simulation results using this method show efficiency increase and devices temperature cycles slightly decreased. Experimental results on a wind...... turbine power stack shows efficiency increase in the high power region....

  12. Design of ultrathin dual-resonant reflective polarization converter with customized bandwidths

    Science.gov (United States)

    Kundu, Debidas; Mohan, Akhilesh; Chakrabarty, Ajay

    2017-10-01

    In this paper, an ultrathin dual-resonant reflective polarization converter is proposed to obtain customized bandwidths using precise space-filling technique to its top geometry. The unit cell of the dual-resonant prototype consists of conductive square ring with two diagonally arranged slits, supported by metal-backed thin dielectric layer. It offers two narrow bands with fractional bandwidths of 3.98 and 6.65% and polarization conversion ratio (PCR) of 97.16 and 98.87% at 4.52 and 6.97 GHz, respectively. The resonances are brought in proximity to each other by changing the length of surface current paths of the two resonances. By virtue of this mechanism, two polarization converters with two different types of bandwidths are obtained. One polarization converter produces a full-width at half-maxima PCR bandwidth of 34%, whereas another polarization converter produces a 90% PCR bandwidth of 19%. All the proposed polarization converters are insensitive to wide variations of incident angle for both TE- and TM-polarized incident waves. Measured results show good agreement with the numerically simulated results.

  13. CCLIBS: The CERN Power Converter Control Libraries

    CERN Document Server

    AUTHOR|(SzGeCERN)404953; Lebioda, Krzysztof Tomasz; Magrans De Abril, Marc; Martino, Michele; Murillo Garcia, Raul; Nicoletti, Achille

    2015-01-01

    Accurate control of power converters is a vital activity in large physics projects. Several different control scenarios may coexist, including regulation of a circuit’s voltage, current, or field strength within a magnet. Depending on the type of facility, a circuit’s reference value may be changed asynchronously or synchronously with other circuits. Synchronous changes may be on demand or under the control of a cyclic timing system. In other cases, the reference may be calculated in real-time by an outer regulation loop of some other quantity, such as the tune of the beam in a synchrotron. The power stage may be unipolar or bipolar in voltage and current. If it is unipolar in current, it may be used with a polarity switch. Depending on the design, the power stage may be controlled by a firing angle or PWM duty-cycle reference, or a voltage or current reference. All these cases are supported by the CERN Converter Control Libraries (CCLIBS). These open-source C libraries include advanced reference generati...

  14. Contingent convertible bonds as countercyclical capital measures

    Directory of Open Access Journals (Sweden)

    Francois Liebenberg

    2017-06-01

    Aim: The effectiveness of the CCB during contractions is not obvious. Contingent convertible (CoCo bonds – which are bond-like until triggered by a deterioration of a prescribed capital metric, at which point they convert into a form of equity – are explored as a supplementary countercyclical capital measure for such periods to establish whether or not they function effectively. Setting: The analysis is undertaken using global bank CoCo data, and then applied to South African banks. Methods: The Hodrick Prescott filter was applied to empirical historical data. Results: The CCB functions as a good countercyclical capital measure in times of economic expansion by absorbing losses and stabilising the capital base through equity issuance. Conclusion: The issuance of CoCo bonds – if their trigger mechanisms are designed correctly – may prove helpful to banks and the broader financial sector in times of economic contraction through the countercyclical capital properties that manifest through CoCo bonds under these economic conditions.

  15. Liner-converter experiment on AMBIORIX

    Energy Technology Data Exchange (ETDEWEB)

    Gasque, A M; Grua, P; Romary, P [Commissariat a l` Energie Atomique, Centre d` Etudes Scientifiques et Techniques d` Aquitaine, Le Barp (France); and others

    1997-12-31

    A new way to transform a quite large part of magnetic energy stored in a Z-pinch plasma into X-rays was first proposed by Rudakov: using an axial magnetic field B{sub z}, a large part of the energy is expected to be transferred by axial electron conductivity to a converter which is placed perpendicularly to the axis of the plasma in order to produce a bright soft X-ray source. In this paper, experimental results obtained on the `AMBIORIX` generator are presented. A hollow cylindrical liner of helium was driven by a current reaching 2 MA in 50 ns. The implosion was studied with and without axial magnetic field, a steady regime of implosion is observed using B{sub z} = 0.3 T. The plasma parameters and the heating of an aluminium converter were measured using various diagnostics. The experimental data were analyzed in detail and compared with the results of numerical simulation. (author). 2 tabs., 2 figs., 5 refs.

  16. Resonant Tunneling Analog-To-Digital Converter

    Science.gov (United States)

    Broekaert, T. P. E.; Seabaugh, A. C.; Hellums, J.; Taddiken, A.; Tang, H.; Teng, J.; vanderWagt, J. P. A.

    1995-01-01

    As sampling rates continue to increase, current analog-to-digital converter (ADC) device technologies will soon reach a practical resolution limit. This limit will most profoundly effect satellite and military systems used, for example, for electronic countermeasures, electronic and signal intelligence, and phased array radar. New device and circuit concepts will be essential for continued progress. We describe a novel, folded architecture ADC which could enable a technological discontinuity in ADC performance. The converter technology is based on the integration of multiple resonant tunneling diodes (RTD) and hetero-junction transistors on an indium phosphide substrate. The RTD consists of a layered semiconductor hetero-structure AlAs/InGaAs/AlAs(2/4/2 nm) clad on either side by heavily doped InGaAs contact layers. Compact quantizers based around the RTD offer a reduction in the number of components and a reduction in the input capacitance Because the component count and capacitance scale with the number of bits N, rather than by 2 (exp n) as in the flash ADC, speed can be significantly increased, A 4-bit 2-GSps quantizer circuit is under development to evaluate the performance potential. Circuit designs for ADC conversion with a resolution of 6-bits at 25GSps may be enabled by the resonant tunneling approach.

  17. Protocol Monitoring Energy Conservation; Protocol Monitoring Energiebesparing

    Energy Technology Data Exchange (ETDEWEB)

    Boonekamp, P.G.M. [ECN Beleidsstudies, Petten (Netherlands); Mannaerts, H. [Centraal Planburea CPB, Den Haag (Netherlands); Tinbergen, W. [Centraal Bureau voor de Statistiek CBS, Den Haag (Netherlands); Vreuls, H.H.J. [Nederlandse onderneming voor energie en milieu Novem, Utrecht (Netherlands); Wesselink, B. [Rijksinstituut voor Volksgezondheid en Milieuhygiene RIVM, Bilthoven (Netherlands)

    2001-12-01

    On request of the Dutch ministry of Economic Affairs five institutes have collaborated to create a 'Protocol Monitoring Energy Conservation', a common method and database to calculate the amount of energy savings realised in past years. The institutes concerned are the Central Bureau of Statistics (CBS), the Netherlands Bureau for Economic Policy Analysis (CPB), the Energy research Centre of the Netherlands (ECN), the National Agency for Energy and Environment (Novem) and the Netherlands Institute of Public Health and the Environment (RIVM). The institutes have agreed upon a clear definition of energy use and energy savings. The demarcation with renewable energy, the saving effects of substitution between energy carriers and the role of import and export of energy have been elaborated. A decomposition method is used to split up the observed change in energy use in a number of effects, on a national and sectoral level. This method includes an analysis of growth effects, effects of structural changes in production and consumption activities and savings on end use or with more efficient conversion processes. To calculate these effects the total energy use is desegregated as much as possible. For each segment a reference energy use is calculated according to the trend in a variable which is supposed to be representative for the use without savings. The difference with the actual energy use is taken as the savings realised. Results are given for the sectors households, industry, agriculture, services and government, transportation and the energy sector; as well as a national figure. A special feature of the protocol method is the application of primary energy use figures in the determination of savings for end users. This means that the use of each energy carrier is increased with a certain amount, according to the conversion losses caused elsewhere in the energy system. The losses concern the base year energy sector and losses abroad for imports of secondary

  18. Efficient Wide Range Converters (EWiRaC): A new family of high efficient AC-DC Converters

    DEFF Research Database (Denmark)

    Petersen, Lars; Andersen, Michael Andreas E.

    2006-01-01

    The performance in terms of efficiency of the existing power supplies used for PFC is very dependent on the input voltage range. The boost converter is the most commonly used PFC converter because of its simplicity and high efficiency. But, the boost converter as well as other known converters...... suffers a major penalty in efficiency when used at the low end of the voltage range (90VAC) in a universal voltage range application (90-270VAC). This paper addresses this problem by suggesting a new family of converters that effectively reduces the apparent voltage range with a factor of 2 by changing...... the converter topology according to the input voltage. This new converter type has been named: efficient wide range converter (EWiRaC). The performance of the EWiRaC is experimental verified in a universal input range (90-270VAC) application with an output voltage of 185VDC capable of 500W output power. The EWi...

  19. Immunocytochemical methods and protocols

    National Research Council Canada - National Science Library

    Javois, Lorette C

    1999-01-01

    ... monoclonal antibodies to study cell differentiation during embryonic development. For a select few disciplines volumes have been published focusing on the specific application of immunocytochemical techniques to that discipline. What distinguished Immunocytochemical Methods and Protocols from earlier books when it was first published four years ago was i...

  20. Critical Response Protocol

    Science.gov (United States)

    Ellingson, Charlene; Roehrig, Gillian; Bakkum, Kris; Dubinsky, Janet M.

    2016-01-01

    This article introduces the Critical Response Protocol (CRP), an arts-based technique that engages students in equitable critical discourse and aligns with the "Next Generation Science Standards" vision for providing students opportunities for language learning while advancing science learning (NGSS Lead States 2013). CRP helps teachers…

  1. Linear Logical Voting Protocols

    DEFF Research Database (Denmark)

    DeYoung, Henry; Schürmann, Carsten

    2012-01-01

    Current approaches to electronic implementations of voting protocols involve translating legal text to source code of an imperative programming language. Because the gap between legal text and source code is very large, it is difficult to trust that the program meets its legal specification. In r...

  2. Principles of Protocol Design

    DEFF Research Database (Denmark)

    Sharp, Robin

    This is a new and updated edition of a book first published in 1994. The book introduces the reader to the principles used in the construction of a large range of modern data communication protocols, as used in distributed computer systems of all kinds. The approach taken is rather a formal one...

  3. Three new DC-to-DC Single-Switch Converters

    Directory of Open Access Journals (Sweden)

    Barry W. Williams

    2017-06-01

    Full Text Available This paper presents a new family of three previously unidentified dc-to-dc converters, buck, boost, and buck-boost voltage-transfer-function topologies, which offer advantageous transformer coupling features and low capacitor dc voltage stressing. The three single-switch, single-diode, converters offer the same features as basic dc-to-dc converters, such as the buck function with continuous output current and the boost function with continuous input current. Converter time-domain simulations and experimental results (including transformer coupling support and extol the dc-to-dc converter concepts and analysis presented.

  4. Comparative Analysis of Resonant Converters for Energy Storage Systems

    Directory of Open Access Journals (Sweden)

    Vuchev Stoyan

    2017-01-01

    Full Text Available The following paperwork presents a comparative analysis of multiphase resonant converters for applications in energy storage systems. Models of the examined converters are developed in the software environments of MATLAB and LTspice. Results from the simulation examination of the converters during charging of supercapacitors and rechargeable batteries are presented. These results are compared to results obtained from experimental examination of the converters via a laboratory stand. For the purposes of the experimental examination, a control system is developed on the base of a virtual instrument in LabVIEW. The advantages and disadvantages of the different converters are discussed.

  5. Novel zero voltage transition pulse width modulation flyback converter

    Science.gov (United States)

    Adib, Ehsan; Farzanehfard, Hosein

    2010-09-01

    In this article, a new zero voltage (ZV) transition flyback converter is introduced which uses a simple auxiliary circuit. In this converter, ZV switching condition is achieved for the converter switch while zero current switching condition is attained for the auxiliary switch. There is no additional voltage and current stress on the main switch. Main diode, auxiliary circuit voltage and current ratings are low. The proposed converter is analysed and design procedure is discussed. The presented experimental results of a prototype converter justify the theoretical analysis.

  6. Research on Compensating Power Converter used for Artillery

    Directory of Open Access Journals (Sweden)

    Xing Wang

    2014-11-01

    Full Text Available Aiming at the low efficiency shortage of traditional power supply converter used for artillery, a novel compensating power converter used for artillery was proposed, and its work mode was analyzed. The current expression of inductor was given and work statuses under two working modes were analyzed. Finally an experimental prototype based on DSP was built, the results indicate that the compensating power converter own low current and voltage stress and high efficiency because only part of power pass through the converter, thus, the converter own large potential application value.

  7. Two phase interleaved buck converter for driving high power LEDs

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2011-01-01

    The goal of this paper is to evaluate an interleaved buck topology for driving high current light-emitting diodes. Low output capacitor value allows the use of non-electrolytic capacitors extending the lifetime of the converter. Converter is operated as a constant, regulated current source which...... increases luminous efficacy of LED compared to PWM dimmed system. Because of the low dynamic resistance of LEDs the duty cycle of the converter does not change greatly with controlled current. By setting the input voltage of the buck converter to around twice the voltage of diode strings, converter can...

  8. Model Additional Protocol

    International Nuclear Information System (INIS)

    Rockwood, Laura

    2001-01-01

    Since the end of the cold war a series of events has changed the circumstances and requirements of the safeguards system. The discovery of a clandestine nuclear weapons program in Iraq, the continuing difficulty in verifying the initial report of Democratic People's Republic of Korea upon entry into force of their safeguards agreement, and the decision of the South African Government to give up its nuclear weapons program and join the Treaty on the Non-Proliferation of Nuclear Weapons have all played a role in an ambitious effort by IAEA Member States and the Secretariat to strengthen the safeguards system. A major milestone in this effort was reached in May 1997 when the IAEA Board of Governors approved a Model Protocol Additional to Safeguards Agreements. The Model Additional Protocol was negotiated over a period of less than a year by an open-ended committee of the Board involving some 70 Member States and two regional inspectorates. The IAEA is now in the process of negotiating additional protocols, State by State, and implementing them. These additional protocols will provide the IAEA with rights of access to information about all activities related to the use of nuclear material in States with comprehensive safeguards agreements and greatly expanded physical access for IAEA inspectors to confirm or verify this information. In conjunction with this, the IAEA is working on the integration of these measures with those provided for in comprehensive safeguards agreements, with a view to maximizing the effectiveness and efficiency, within available resources, the implementation of safeguards. Details concerning the Model Additional Protocol are given. (author)

  9. Multilevel Converter by Cascading Two-Level Three-Phase Voltage Source Converter

    Directory of Open Access Journals (Sweden)

    Abdullrahman A. Al-Shamma’a

    2018-04-01

    Full Text Available This paper proposes a topology using isolated, cascaded multilevel voltage source converters (VSCs and employing two-winding magnetic elements for high-power applications. The proposed topology synthesizes 6 two-level, three-phase VSCs, so the power capability of the presented converter is six times the capability of each VSC module. The characteristics of the proposed topology are demonstrated through analyzing its current relationships, voltage relationships and power capability in detail. The power rating is equally shared among the VSC modules without the need for a sharing algorithm; thus, the converter operates as a single three-phase VSC. The comparative analysis with classical neutral-point clamped, flying capacitor and cascaded H-bridge exhibits the superior features of fewer insulated gate bipolar transistors (IGBTs, capacitor requirement and fewer diodes. To validate the theoretical performance of the proposed converter, it is simulated in a MATLAB/Simulink environment and the results are experimentally demonstrated using a laboratory prototype.

  10. Artificial neural network control of sab dc/dc converter

    International Nuclear Information System (INIS)

    Mahar, M.A.; Abro, M.R.; Larik, A.S.

    2009-01-01

    The latest development of power semiconductor devices enable the modern power electronic converters to withstand high voltage and high power applications. Power electronic converters are mostly periodic variable structure systems due to their switched operations. The main drawback of these converters is the generation of oscillations which are developed during the operation of the converters under nonlinear situations. To handle these nonlinearities, various researchers have proposed different control techniques. Power electronic designers are devoting in the further development of converter topologies and their control techniques. SAB (Single Active Bridge) DC/DC converter is a new topology recently introduced by Demetriades. This topology is used in high voltage and high power applications. Because of its smart features, SAB converter has recently drawn attention of many researchers. However, during the operation of SAB converter severe oscillations are generated. In this research work, a novel NNC (Neural Network Controller) model is developed for SAB converter to minimize oscillations generated during its operation. NNC is believed to be an advanced nonlinear and robust controller which has the ability to map the nonlinear behaviour in a negligible response time. The performance of SAB converter with NNC is tested under dynamic region by considering the reference voltage variation and duty ratio variation. The SAB converter is implemented and simulated in MATLAB/Simulink. The simulated results are presented. (author)

  11. Soft switching PWM isolated boost converter for fuel cell application

    Energy Technology Data Exchange (ETDEWEB)

    Rezaei, M.; Adib, E. [Isfahan Univ. of Technology, Isfahan (Iran, Islamic Republic of)

    2009-07-01

    This presentation introduced a newly developed soft switching, isolated boost type converter for fuel cell applications. With a simple PWM control circuit, the converter achieves zero voltage switching the main switch. Since the auxiliary circuit is soft switched, the converter can operate at high powers which make it suitable for fuel cell applications. In particular, the converter is suitable for the interface of fuel cell and inverters because of its high voltage gain and isolation between input and output sources. In addition, the input current of the converter (current drained from the fuel cell) is almost constant since it is a boost type converter. The converter was analyzed and the simulation results validate the theoretical analysis.

  12. Pricing Chinese Convertible Bonds with Dynamic Credit Risk

    Directory of Open Access Journals (Sweden)

    Ping Li

    2014-01-01

    Full Text Available To price convertible bonds more precisely, least squares Monte Carlo (LSM method is used in this paper for its advantage in handling the dependence of derivatives on the path, and dynamic credit risk is used to replace the fixed one to make the value of convertible bonds reflect the real credit risk. In the empirical study, we price convertible bonds based on static credit risk and dynamic credit risk, respectively. Empirical results indicate that the ICBC convertible bond has been overpriced, resulting from the underestimation of credit risk. In addition, when there is an issue of dividend, the conversion price will change in China's convertible bonds, while it does not change in the international convertible bonds. So we also empirically study the difference between the convertible bond's prices by assuming whether the conversion price changes or not.

  13. Benefits and Drawbacks of A High Frequency Gan Zvzcps Converter

    Directory of Open Access Journals (Sweden)

    Blanes J. M.

    2017-01-01

    Full Text Available This paper presents the benefits and drawbacks of replacing the traditional Si Mosfets transistors with enhancement mode GaN transistors in a Half-Bridge Zero Voltage and Zero Current Switching Power Switching (ZVZCPS converter. This type of converters is usually used as Electronic Power Converters (EPC for telecommunication satellites travelling-wave tube amplifiers (TWTAs. In this study, firstly the converter is theoretically analysed, obtaining its operation, losses and efficiency equations. From these equations, optimizations maps based on the main system parameters are obtained. These optimization maps are the key to quantify the potential benefits of GaN transistors in this type of converters. Theoretical results show that using GaN transistors, the frequency of the converter can be pushed from 125kHz to 830kHz without sacrificing the converter efficiency. This frequency increase is directly related to reduction on the EPC size and weight.

  14. Converter applications and their influence on large electrical machines

    CERN Document Server

    Drubel, Oliver

    2013-01-01

    Converter driven applications are applied in more and more processes. Almost any installed wind-farm, ship drives, steel mills, several boiler feed water pumps, extruder and many other applications operate much more efficient and economic in case of variable speed solutions. The boundary conditions for a motor or generator will change, if it is supplied by a converter. An electrical machine, which is operated by a converter, can no longer be regarded as an independent component, but is embedded in a system consisting of converter and machine. This book gives an overview of existing converter designs for large electrical machines. Methods for the appropriate calculation of machine phenomena, which are implied by converters are derived in the power range above 500kVA. It is shown how due to the converter inherent higher voltage harmonics and pulse frequencies special phenomena are caused inside the machine which can be the reason for malfunction. It is demonstrated that additional losses create additional tempe...

  15. Effect of inlet cone pipe angle in catalytic converter

    Science.gov (United States)

    Amira Zainal, Nurul; Farhain Azmi, Ezzatul; Arifin Samad, Mohd

    2018-03-01

    The catalytic converter shows significant consequence to improve the performance of the vehicle start from it launched into production. Nowadays, the geometric design of the catalytic converter has become critical to avoid the behavior of backpressure in the exhaust system. The backpressure essentially reduced the performance of vehicles and increased the fuel consumption gradually. Consequently, this study aims to design various models of catalytic converter and optimize the volume of fluid flow inside the catalytic converter by changing the inlet cone pipe angles. Three different geometry angles of the inlet cone pipe of the catalytic converter were assessed. The model is simulated in Solidworks software to determine the optimum geometric design of the catalytic converter. The result showed that by decreasing the divergence angle of inlet cone pipe will upsurge the performance of the catalytic converter.

  16. Layout Optimisation of Wave Energy Converter Arrays

    Directory of Open Access Journals (Sweden)

    Pau Mercadé Ruiz

    2017-08-01

    Full Text Available This paper proposes an optimisation strategy for the layout design of wave energy converter (WEC arrays. Optimal layouts are sought so as to maximise the absorbed power given a minimum q-factor, the minimum distance between WECs, and an area of deployment. To guarantee an efficient optimisation, a four-parameter layout description is proposed. Three different optimisation algorithms are further compared in terms of performance and computational cost. These are the covariance matrix adaptation evolution strategy (CMA, a genetic algorithm (GA and the glowworm swarm optimisation (GSO algorithm. The results show slightly higher performances for the latter two algorithms; however, the first turns out to be significantly less computationally demanding.

  17. Will oscillating wave surge converters survive tsunamis?

    Directory of Open Access Journals (Sweden)

    L. O’Brien

    2015-07-01

    Full Text Available With an increasing emphasis on renewable energy resources, wave power technology is becoming one of the realistic solutions. However, the 2011 tsunami in Japan was a harsh reminder of the ferocity of the ocean. It is known that tsunamis are nearly undetectable in the open ocean but as the wave approaches the shore its energy is compressed, creating large destructive waves. The question posed here is whether an oscillating wave surge converter (OWSC could withstand the force of an incoming tsunami. Several tools are used to provide an answer: an analytical 3D model developed within the framework of linear theory, a numerical model based on the non-linear shallow water equations and empirical formulas. Numerical results show that run-up and draw-down can be amplified under some circumstances, leading to an OWSC lying on dry ground!

  18. Power Generation Using Mechanical Wave Energy Converter

    Directory of Open Access Journals (Sweden)

    Srinivasan Chandrasekaran

    2012-03-01

    Full Text Available Ocean wave energy plays a significant role in meeting the growing demand of electric power. Economic, environmental, and technical advantages of wave energy set it apart from other renewable energy resources. Present study describes a newly proposed Mechanical Wave Energy Converter (MEWC that is employed to harness heave motion of floating buoy to generate power. Focus is on the conceptual development of the device, illustrating details of component level analysis. Employed methodology has many advantages such as i simple and easy fabrication; ii easy to control the operations during rough weather; and iii low failure rate during normal sea conditions. Experimental investigations carried out on the scaled model of MWEC show better performance and its capability to generate power at higher efficiency in regular wave fields. Design Failure Mode and Effect Analysis (FMEA shows rare failure rates for all components except the floating buoy.

  19. Mechanical vibration to electrical energy converter

    Science.gov (United States)

    Kellogg, Rick Allen [Tijeras, NM; Brotz, Jay Kristoffer [Albuquerque, NM

    2009-03-03

    Electromechanical devices that generate an electrical signal in response to an external source of mechanical vibrations can operate as a sensor of vibrations and as an energy harvester for converting mechanical vibration to electrical energy. The devices incorporate a magnet that is movable through a gap in a ferromagnetic circuit, wherein a coil is wound around a portion of the ferromagnetic circuit. A flexible coupling is used to attach the magnet to a frame for providing alignment of the magnet as it moves or oscillates through the gap in the ferromagnetic circuit. The motion of the magnet can be constrained to occur within a substantially linear range of magnetostatic force that develops due to the motion of the magnet. The devices can have ferromagnetic circuits with multiple arms, an array of magnets having alternating polarity and, encompass micro-electromechanical (MEM) devices.

  20. Generators for gearless wind energy converters

    Energy Technology Data Exchange (ETDEWEB)

    Grauers, A. [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Electric Power Engineering

    1996-12-01

    This paper discusses some design alternatives for directly driven generators, and one specific generator type is investigated for a wide range of rated power. First, the specification for a directly driven generator is presented, then different design alternatives are discussed. A radial-flux permanent magnet generator for frequency converter connection has been chosen for a more detailed investigation. The design, optimization and performance of that generator type are presented. Generators from 30 kW to 3 MW are designed and compared with conventional four-pole generators with gear. It is found that a directly driven generator can be more efficient than a conventional generator and gear and have a rather small diameter and a low active weight. 8 refs, 7 figs, 2 tabs

  1. Large-scale digitizer system, analog converters

    International Nuclear Information System (INIS)

    Althaus, R.F.; Lee, K.L.; Kirsten, F.A.; Wagner, L.J.

    1976-10-01

    Analog to digital converter circuits that are based on the sharing of common resources, including those which are critical to the linearity and stability of the individual channels, are described. Simplicity of circuit composition is valued over other more costly approaches. These are intended to be applied in a large-scale processing and digitizing system for use with high-energy physics detectors such as drift-chambers or phototube-scintillator arrays. Signal distribution techniques are of paramount importance in maintaining adequate signal-to-noise ratio. Noise in both amplitude and time-jitter senses is held sufficiently low so that conversions with 10-bit charge resolution and 12-bit time resolution are achieved

  2. Passive components used in power converters

    CERN Document Server

    Rufer, A; Barrade, P

    2006-01-01

    In power converters, passive components play an important role, and have in general specific nature and properties. The goal of this tutorial is to give an overview, first on inductive components for power conversion, and second on dedicated power capacitors. In a third part, new components— supercapacitors—will be presented. Generally, inductors for power applications must be custom designed. In this tutorial, the most important effects encountered when realising inductive components will be presented in the first part, without entering into the detailed design of such components. For that purpose, the referenced documents that have served as a base for this tutorial must be consulted [1], [2], and mainly [3]. The second part of this tutorial (Capacitors used in power electronics) is dedicated to power capacitors. Unlike inductors, capacitors cannot be specifically designed, but must be selected from a manufacturer’s list of components. Here, the documentation corresponds to a subset of Ref. [4] that h...

  3. Halo scraper/direct converter system study

    International Nuclear Information System (INIS)

    Luzzi, T.; Clarkson, I.; Barr, W.; Neef, W.

    1985-01-01

    During the first year of the LLNL Minimars program, a system study was undertaken to determine the most efficient method for recovery of the end cell thermal energy. The goal of the study was to recovery energy at the highest possible coolant temperature and therefore at the highest thermal efficiency. Two types of coolant were considered, water and gaseous helium. In a system study where the goal is to recover maximum thermal power in an economically designed device, it is necessary to place constraints on the design. The four constraints for the direct converter are somewhat conflicting in that a particularly design solution satisfying one may lead to an unacceptable solution for another. The final design choice must be a compromise that satisfies all the constraints

  4. Simplifying the circuit of Josephson parametric converters

    Science.gov (United States)

    Abdo, Baleegh; Brink, Markus; Chavez-Garcia, Jose; Keefe, George

    Josephson parametric converters (JPCs) are quantum-limited three-wave mixing devices that can play various important roles in quantum information processing in the microwave domain, including amplification of quantum signals, transduction of quantum information, remote entanglement of qubits, nonreciprocal amplification, and circulation of signals. However, the input-output and biasing circuit of a state-of-the-art JPC consists of bulky components, i.e. two commercial off-chip broadband 180-degree hybrids, four phase-matched short coax cables, and one superconducting magnetic coil. Such bulky hardware significantly hinders the integration of JPCs in scalable quantum computing architectures. In my talk, I will present ideas on how to simplify the JPC circuit and show preliminary experimental results

  5. Performance Evaluation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Pecher, Arthur

    Ocean waves provide a sustainable, power-dense, predictable and widely available source of energy that could provide about 10 % of worlds energy needs. While research into waveenergy has been undertaken for decades, a significant increase in related activities has been seen in the recent years......, with more than 150 concepts currently being developed worldwide. Wave energy conversion concepts can be of many kinds, as the energy in the waves can be absorbed in many different ways. However, each concept is expected to require a thorough development process, involving different phases and prototypes....... Guidelines for the development of wave energy converters recommend the use of different prototypes, having different sizes, which have to perform tank tests or sea trials. Thisimplicates the need of different testing environment, which shifts from being controllable to uncontrollable with the development...

  6. Modular Multilevel Converters: Control and Applications

    Directory of Open Access Journals (Sweden)

    Fernando Martinez-Rodrigo

    2017-10-01

    Full Text Available This review article is mainly oriented to the control and applications of modular multilevel converters (MMC. The main topologies of the switching modules are presented, for normal operation and for the elimination of DC faults. Methods to keep the capacitor voltage balanced are included. The voltage and current modulators, that are the most internal loops of control, are detailed. Voltage control and current control schemes are included which regulate DC link voltage and reactive power. The cases of unbalanced and distorted networks are analyzed, and schemes are proposed so that MMC contribute to improve the quality of the grid in these situations. The main applications in high voltage direct current (HVDC transmission along with other medium voltage (MV and low voltage (LV applications are included. Finally, the application to offshore wind farms is specifically analyzed.

  7. Clustering of cycloidal wave energy converters

    Science.gov (United States)

    Siegel, Stefan G.

    2016-03-29

    A wave energy conversion system uses a pair of wave energy converters (WECs) on respective active mountings on a floating platform, so that the separation of the WECs from each other or from a central WEC can be actively adjusted according to the wavelength of incident waves. The adjustable separation facilitates operation of the system to cancel reactive forces, which may be generated during wave energy conversion. Modules on which such pairs of WECs are mounted can be assembled with one or more central WECs to form large clusters in which reactive forces and torques can be made to cancel. WECs of different sizes can be employed to facilitate cancelation of reactive forces and torques.

  8. Dentists United to Extinguish Tobacco (DUET): a study protocol for a cluster randomized, controlled trial for enhancing implementation of clinical practice guidelines for treating tobacco dependence in dental care settings.

    Science.gov (United States)

    Ostroff, Jamie S; Li, Yuelin; Shelley, Donna R

    2014-02-21

    Although dental care settings provide an exceptional opportunity to reach smokers and provide brief cessation advice and treatment to reduce oral and other tobacco-related health conditions, dental care providers demonstrate limited adherence to evidence-based guidelines for treatment of tobacco use and dependence. Guided by a multi-level, conceptual framework that emphasizes changes in provider beliefs and organizational characteristics as drivers of improvement in tobacco treatment delivery, the current protocol will use a cluster, randomized design and multiple data sources (patient exit interviews, provider surveys, site observations, chart audits, and semi-structured provider interviews) to study the process of implementing clinical practice guidelines for treating tobacco dependence in 18 public dental care clinics in New York City. The specific aims of this comparative-effectiveness research trial are to: compare the effectiveness of three promising strategies for implementation of tobacco use treatment guidelines-staff training and current best practices (CBP), CBP + provider performance feedback (PF), and CBP + PF + provider reimbursement for delivery of tobacco cessation treatment (pay-for-performance, or P4P); examine potential theory-driven mechanisms hypothesized to explain the comparative effectiveness of three strategies for implementation; and identify baseline organizational factors that influence the implementation of evidence-based tobacco use treatment practices in dental clinics. The primary outcome is change in providers' tobacco treatment practices and the secondary outcomes are cost per quit, use of tobacco cessation treatments, quit attempts, and smoking abstinence. We hypothesize that the value of these promising implementation strategies is additive and that incorporating all three strategies (CBP, PF, and P4P) will be superior to CBP alone and CBP + PF in improving delivery of cessation assistance to smokers. The findings

  9. Lack of validation of the Dixtal (DX 2020) upper arm blood pressure monitor, in oscillometric mode, for clinical use in an intensive care unit, according to the European Society of Hypertension-International Protocol revision 2010.

    Science.gov (United States)

    Gothardo, Ana C L O; Savioli, Amanda F; Santos, Dayanna S; Lamas, José L T

    2013-08-01

    The aim of the study was to evaluate the accuracy of the oscillometric blood pressure section in the DX 2020 Dixtal multiparametric monitor in adults according to the European Society of Hypertension-International Protocol as revised in 2010 (ESH-IP 2010). The blood pressure was sequentially verified in 33 individuals admitted to an adult ICU (18 men, mean age 44 years) with a mercury column sphygmomanometer (two observers) and the DX 2020 test device (one supervisor). Ninety-nine pairs of differences were obtained. Data analysis followed the ESH-IP 2010 requirements. In the first requirement, the DX 2020 device failed in the validation study in the 5, 10, and 15 mmHg ranges. From the 99 pairs of differences, only 43/73, 69/87, and 81/96 were obtained for systolic blood pressure and 29/65, 56/81, and 71/93 were obtained for diastolic blood pressure. In the second requirement, at least 24 individuals should have, from their comparisons, two under 0-5 mmHg ranges, which was observed only with 16 individuals in the systolic and nine in the diastolic range. Moreover, at maximum, only three readings could have differences of more than 5 mmHg, and this was observed in 10 individuals in the systolic range and 17 individuals in the diastolic range. The DX 2020 automatic multiparametric monitor for blood pressure measurement has not been recommended for clinical use according to the ESH-IP 2010. It is important to highlight that this work refers only to a blood pressure measurement module and that the same conclusion cannot be drawn for its other functions.

  10. Effectiveness of a structured education reminiscence-based programme for staff on the quality of life of residents with dementia in long-stay units: A study protocol for a cluster randomised trial

    LENUS (Irish Health Repository)

    O'Shea, Eamon

    2011-02-14

    Abstract Background Current projections indicate that there will be a significant increase in the number of people with dementia in Ireland, from approximately 40,000 at present to 100,000 by 2036. Psychosocial interventions, such as reminiscence, have the potential to improve the quality of life of people with dementia. However, while reminiscence is used widely in dementia care, its impact on the quality of life of people with dementia remains largely undocumented and there is a need for a robust and fair assessment of its overall effectiveness. The DementiA education programme incorporating REminiscence for Staff study will evaluate the effectiveness of a structured reminiscence-based education programme for care staff on the quality of life of residents with dementia in long-stay units. Methods\\/Design The study is a two-group, single-blind cluster randomised trial conducted in public and private long-stay residential settings in Ireland. Randomisation to control and intervention is at the level of the long-stay residential unit. Sample size calculations suggest that 18 residential units each containing 17 people with dementia are required for randomisation to control and intervention groups to achieve power of at least 80% with alpha levels of 0.05. Each resident in the intervention group is linked with a nurse and care assistant who have taken the structured reminiscence-based education programme. Participants in the control group will receive usual care. The primary outcome is quality of life of residents as measured by the Quality of Life-AD instrument. Secondary outcomes include agitation, depression and carer burden. Blinded outcome assessment is undertaken at baseline and at 18-22 weeks post-randomisation. Discussion Trials on reminiscence-based interventions for people with dementia have been scarce and the quality of the information arising from those that have been done has been undermined by methodological problems, particularly in relation to scale

  11. Effectiveness of a structured education reminiscence-based programme for staff on the quality of life of residents with dementia in long-stay units: A study protocol for a cluster randomised trial

    Directory of Open Access Journals (Sweden)

    Jordan Fionnuala

    2011-02-01

    Full Text Available Abstract Background Current projections indicate that there will be a significant increase in the number of people with dementia in Ireland, from approximately 40,000 at present to 100,000 by 2036. Psychosocial interventions, such as reminiscence, have the potential to improve the quality of life of people with dementia. However, while reminiscence is used widely in dementia care, its impact on the quality of life of people with dementia remains largely undocumented and there is a need for a robust and fair assessment of its overall effectiveness. The DementiA education programme incorporating REminiscence for Staff study will evaluate the effectiveness of a structured reminiscence-based education programme for care staff on the quality of life of residents with dementia in long-stay units. Methods/Design The study is a two-group, single-blind cluster randomised trial conducted in public and private long-stay residential settings in Ireland. Randomisation to control and intervention is at the level of the long-stay residential unit. Sample size calculations suggest that 18 residential units each containing 17 people with dementia are required for randomisation to control and intervention groups to achieve power of at least 80% with alpha levels of 0.05. Each resident in the intervention group is linked with a nurse and care assistant who have taken the structured reminiscence-based education programme. Participants in the control group will receive usual care. The primary outcome is quality of life of residents as measured by the Quality of Life-AD instrument. Secondary outcomes include agitation, depression and carer burden. Blinded outcome assessment is undertaken at baseline and at 18-22 weeks post-randomisation. Discussion Trials on reminiscence-based interventions for people with dementia have been scarce and the quality of the information arising from those that have been done has been undermined by methodological problems, particularly in

  12. Biocoder: A programming language for standardizing and automating biology protocols.

    Science.gov (United States)

    Ananthanarayanan, Vaishnavi; Thies, William

    2010-11-08

    Published descriptions of biology protocols are often ambiguous and incomplete, making them difficult to replicate in other laboratories. However, there is increasing benefit to formalizing the descriptions of protocols, as laboratory automation systems (such as microfluidic chips) are becoming increasingly capable of executing them. Our goal in this paper is to improve both the reproducibility and automation of biology experiments by using a programming language to express the precise series of steps taken. We have developed BioCoder, a C++ library that enables biologists to express the exact steps needed to execute a protocol. In addition to being suitable for automation, BioCoder converts the code into a readable, English-language description for use by biologists. We have implemented over 65 protocols in BioCoder; the most complex of these was successfully executed by a biologist in the laboratory using BioCoder as the only reference. We argue that BioCoder exposes and resolves ambiguities in existing protocols, and could provide the software foundations for future automation platforms. BioCoder is freely available for download at http://research.microsoft.com/en-us/um/india/projects/biocoder/. BioCoder represents the first practical programming system for standardizing and automating biology protocols. Our vision is to change the way that experimental methods are communicated: rather than publishing a written account of the protocols used, researchers will simply publish the code. Our experience suggests that this practice is tractable and offers many benefits. We invite other researchers to leverage BioCoder to improve the precision and completeness of their protocols, and also to adapt and extend BioCoder to new domains.

  13. An interventional skin care protocol (InSPiRE) to reduce incontinence-associated dermatitis in critically ill patients in the intensive care unit: A before and after study.

    Science.gov (United States)

    Coyer, Fiona; Gardner, Anne; Doubrovsky, Anna

    2017-06-01

    This study aimed to test the effectiveness of a bundle combining best available evidence to reduce the incidence of incontinence-associated dermatitis occurrences in critically ill patients. The study used a before and after design and was conducted in an adult intensive care unit of an Australian quartenary referral hospital. Data, collected by trained research nurses, included demographic and clinical variables, skin assessment, incontinence-associated dermatitis presence and severity. Data were analysed using descriptive and inferential statistics. Of the 207 patients enrolled, 146 patients were mechanically ventilated and incontinent thus eligible for analysis, 80 with 768days of observation in the after/intervention group and 66 with 733days of observation in the before group. Most patients were men, mean age 53 years. Groups were similar on demographic variables. Incontinence-associated dermatitis incidence was lower in the intervention group (15%; 12/80) compared to the control group (32%; 21/66) (p=0.016). Incontinence-associated dermatitis events developed later in the intensive care unit stay in the intervention group (Logrank=5.2, p=<0.022). This study demonstrated that the use of a bundle combining best available evidence reduced the incidence and delayed the development of incontinence-associated dermatitis occurrences in critically ill patients. Systematic ongoing patient assessments, combined with tailored prevention measures are central to preventing incontinence-associated dermatitis in this vulnerable patient group. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Satellite Communications Using Commercial Protocols

    Science.gov (United States)

    Ivancic, William D.; Griner, James H.; Dimond, Robert; Frantz, Brian D.; Kachmar, Brian; Shell, Dan

    2000-01-01

    NASA Glenn Research Center has been working with industry, academia, and other government agencies in assessing commercial communications protocols for satellite and space-based applications. In addition, NASA Glenn has been developing and advocating new satellite-friendly modifications to existing communications protocol standards. This paper summarizes recent research into the applicability of various commercial standard protocols for use over satellite and space- based communications networks as well as expectations for future protocol development. It serves as a reference point from which the detailed work can be readily accessed. Areas that will be addressed include asynchronous-transfer-mode quality of service; completed and ongoing work of the Internet Engineering Task Force; data-link-layer protocol development for unidirectional link routing; and protocols for aeronautical applications, including mobile Internet protocol routing for wireless/mobile hosts and the aeronautical telecommunications network protocol.

  15. Further Development of SNL‐Swan, a Validated Wave Energy Converter

    OpenAIRE

    Porter, Aaron; Ruehl, Kelley; Chartrand, Chris

    2014-01-01

    Commercialization of wave energy will lead to the necessary deployment of Wave Energy Converters (WECs) in arrays, or wave farms. In order for projects in the United States to be approved, regulatory agencies must perform an Environmental Assessment proving little to no environmental impact. However, little is known about the environmental impacts of such wave farms. As a result, the environmental impacts of wave farms are largely determined by numerical wave models capable of modeling large ...

  16. Do Callable Convertibles Support The Investment Process Of A Company? An Analysis Of The World Market Of Hybrid Debt

    Directory of Open Access Journals (Sweden)

    Kaźmierczak Damian

    2017-06-01

    Full Text Available Using a sample of 1,705 convertible bonds issued by manufacturing and service companies from the United States (1,138 issues; Europe (270; and Asia (297 between 2004 and 2014 this paper investigates the role of callable convertibles in the corporate investment process. This research shows first that callable convertibles are used to finance investment projects particularly by American firms which may exercise new investment options to improve poor financial performance. Secondly, the same strategy may be followed by European companies, but they seem not to carry out investments on as large a scale as American firms. Thirdly, the research results do not provide evidence that Asian enterprises use callable convertibles for investment purposes: they likely use these instruments for different reasons.

  17. Epistemic Protocols for Distributed Gossiping

    Directory of Open Access Journals (Sweden)

    Krzysztof R. Apt

    2016-06-01

    Full Text Available Gossip protocols aim at arriving, by means of point-to-point or group communications, at a situation in which all the agents know each other's secrets. We consider distributed gossip protocols which are expressed by means of epistemic logic. We provide an operational semantics of such protocols and set up an appropriate framework to argue about their correctness. Then we analyze specific protocols for complete graphs and for directed rings.

  18. Symmetric cryptographic protocols

    CERN Document Server

    Ramkumar, Mahalingam

    2014-01-01

    This book focuses on protocols and constructions that make good use of symmetric pseudo random functions (PRF) like block ciphers and hash functions - the building blocks for symmetric cryptography. Readers will benefit from detailed discussion of several strategies for utilizing symmetric PRFs. Coverage includes various key distribution strategies for unicast, broadcast and multicast security, and strategies for constructing efficient digests of dynamic databases using binary hash trees.   •        Provides detailed coverage of symmetric key protocols •        Describes various applications of symmetric building blocks •        Includes strategies for constructing compact and efficient digests of dynamic databases

  19. Radon in large buildings: The development of a protocol

    International Nuclear Information System (INIS)

    Wilson, D.L.; Dudney, C.S.; Gammage, R.B.

    1993-01-01

    Over the past several years, considerable research has been devoted by the US Environmental Protection Agency (USEPA) and others to develop radon sampling protocols for single family residences and schools. However, very little research has been performed on measuring radon in the work place. To evaluate possible sampling protocols, 833 buildings throughout the United States were selected for extensive radon testing. The buildings tested (warehouses, production plants and office buildings) were representative of commercial buildings across the country both in design, size and use. Based on the results, preliminary radon sampling protocols for the work place have been developed

  20. Diplomacy and Diplomatic Protocol

    Directory of Open Access Journals (Sweden)

    Lect. Ph.D Oana Iucu

    2008-12-01

    Full Text Available The present study aims to observe relationships and determining factors between diplomacyand diplomatic protocol as outlined by historical and contextual analyses. The approach is very dynamic,provided that concepts are able to show their richness, antiquity and polyvalence at the level of connotations,semantics, grammatical and social syntax. The fact that this information is up to date determines anattitude of appreciation and a state of positive contamination.

  1. Intestinal fatty acid binding protein as a marker for intra-abdominal pressure-related complications in patients admitted to the intensive care unit; study protocol for a prospective cohort study (I-Fabulous study).

    Science.gov (United States)

    Strang, Steven G; Van Waes, Oscar J F; Van der Hoven, Ben; Ali, Samir; Verhofstad, Michael H J; Pickkers, Peter; Van Lieshout, Esther M M

    2015-01-16

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) have detrimental effects on all organ systems and are associated with increased morbidity and mortality in critically ill patients admitted to an intensive care unit. Intra-bladder measurement of the intra-abdominal pressure (IAP) is currently the gold standard. However, IAH is not always indicative of intestinal ischemia, which is an early and rapidly developing complication. Sensitive biomarkers for intestinal ischemia are needed to be able to intervene before damage becomes irreversible. Gut wall integrity loss, including epithelial cell disruption and tight junctions breakdown, is an early event in intestinal damage. Intestinal Fatty Acid Binding Protein (I-FABP) is excreted in urine and blood specifically from damaged intestinal epithelial cells. Claudin-3 is a specific protein which is excreted in urine following disruption of intercellular tight junctions. This study aims to investigate if I-FABP and Claudin-3 can be used as a diagnostic tool for identifying patients at risk for IAP-related complications. In a multicenter, prospective cohort study 200 adult patients admitted to the intensive care unit with at least two risk factors for IAH as defined by the World Society of the Abdominal Compartment Syndrome (WSACS) will be included. Patients in whom an intra-bladder IAP measurement is contra-indicated or impossible and patients with inflammatory bowel diseases that may affect I-FABP levels will be excluded. The IAP will be measured using an intra-bladder technique. During the subsequent 72 hours, the IAP measurement will be repeated every six hours. At these time points, a urine and serum sample will be collected for measurement of I-FABP and Claudin-3 levels. Clinical outcome of patients during their stay at the intensive care unit will be monitored using the Sequential Organ Failure Assessment (SOFA) score. Successful completion of this trial will provide evidence on the eventual

  2. Automatic Validation of Protocol Narration

    DEFF Research Database (Denmark)

    Bodei, Chiara; Buchholtz, Mikael; Degano, Pierpablo

    2003-01-01

    We perform a systematic expansion of protocol narrations into terms of a process algebra in order to make precise some of the detailed checks that need to be made in a protocol. We then apply static analysis technology to develop an automatic validation procedure for protocols. Finally, we...

  3. Dysphonia risk screening protocol

    Directory of Open Access Journals (Sweden)

    Katia Nemr

    2016-03-01

    Full Text Available OBJECTIVE: To propose and test the applicability of a dysphonia risk screening protocol with score calculation in individuals with and without dysphonia. METHOD: This descriptive cross-sectional study included 365 individuals (41 children, 142 adult women, 91 adult men and 91 seniors divided into a dysphonic group and a non-dysphonic group. The protocol consisted of 18 questions and a score was calculated using a 10-cm visual analog scale. The measured value on the visual analog scale was added to the overall score, along with other partial scores. Speech samples allowed for analysis/assessment of the overall degree of vocal deviation and initial definition of the respective groups and after six months, the separation of the groups was confirmed using an acoustic analysis. RESULTS: The mean total scores were different between the groups in all samples. Values ranged between 37.0 and 57.85 in the dysphonic group and between 12.95 and 19.28 in the non-dysphonic group, with overall means of 46.09 and 15.55, respectively. High sensitivity and specificity were demonstrated when discriminating between the groups with the following cut-off points: 22.50 (children, 29.25 (adult women, 22.75 (adult men, and 27.10 (seniors. CONCLUSION: The protocol demonstrated high sensitivity and specificity in differentiating groups of individuals with and without dysphonia in different sample groups and is thus an effective instrument for use in voice clinics.

  4. Dysphonia risk screening protocol

    Science.gov (United States)

    Nemr, Katia; Simões-Zenari, Marcia; da Trindade Duarte, João Marcos; Lobrigate, Karen Elena; Bagatini, Flavia Alves

    2016-01-01

    OBJECTIVE: To propose and test the applicability of a dysphonia risk screening protocol with score calculation in individuals with and without dysphonia. METHOD: This descriptive cross-sectional study included 365 individuals (41 children, 142 adult women, 91 adult men and 91 seniors) divided into a dysphonic group and a non-dysphonic group. The protocol consisted of 18 questions and a score was calculated using a 10-cm visual analog scale. The measured value on the visual analog scale was added to the overall score, along with other partial scores. Speech samples allowed for analysis/assessment of the overall degree of vocal deviation and initial definition of the respective groups and after six months, the separation of the groups was confirmed using an acoustic analysis. RESULTS: The mean total scores were different between the groups in all samples. Values ranged between 37.0 and 57.85 in the dysphonic group and between 12.95 and 19.28 in the non-dysphonic group, with overall means of 46.09 and 15.55, respectively. High sensitivity and specificity were demonstrated when discriminating between the groups with the following cut-off points: 22.50 (children), 29.25 (adult women), 22.75 (adult men), and 27.10 (seniors). CONCLUSION: The protocol demonstrated high sensitivity and specificity in differentiating groups of individuals with and without dysphonia in different sample groups and is thus an effective instrument for use in voice clinics. PMID:27074171

  5. Effectiveness of a structured education reminiscence-based programme for staff on the quality of life of residents with dementia in long-stay units: a study protocol for a cluster randomised trial.

    LENUS (Irish Health Repository)

    O'Shea, Eamon

    2011-02-01

    Current projections indicate that there will be a significant increase in the number of people with dementia in Ireland, from approximately 40,000 at present to 100,000 by 2036. Psychosocial interventions, such as reminiscence, have the potential to improve the quality of life of people with dementia. However, while reminiscence is used widely in dementia care, its impact on the quality of life of people with dementia remains largely undocumented and there is a need for a robust and fair assessment of its overall effectiveness. The DementiA education programme incorporating REminiscence for Staff study will evaluate the effectiveness of a structured reminiscence-based education programme for care staff on the quality of life of residents with dementia in long-stay units.

  6. International protocol on volatile organic compounds

    International Nuclear Information System (INIS)

    Gauthier, J.-P.

    1992-01-01

    In August 1991, negotiations between Canada, the USA, and 33 European countries led to an international protocol on reducing the emissions of volatile organic compounds (VOC), which are responsible for serious ozone pollution problems. This was the third transborder pollution agreement developed under the auspices of the United Nations Economic Commission for Europe. Certain aspects of negotiations related to an earlier protocol developed for SO 2 and nitrogen oxide emissions had reappeared during the VOC negotiations, and these aspects are discussed. The VOC protocol proposes three approaches to satisfy basic obligations: reducing VOC emissions of a country by 30%, reducing VOC emissions by 30% in certain regions, and ensuring a freeze in VOC emissions in a country starting on a specified date. The protocol also introduces a new concept, that of zones of tropospheric ozone management. In Canada, plans for management of nitrogen oxides and VOC have been adapted to the ozone problem, and the management plan has been developed by a consultation process involving all sectors of society including industry, environmental groups, and governments. In Canada, it will be sufficient to reduce total VOC emissions by 16% during a first phase and to increase these reductions slightly in the second phase. Special ozone management zones in the Quebec City/Windsor corridor and the Fraser River valley have been established

  7. Internal fit of three-unit fixed dental prostheses produced by computer-aided design/computer-aided manufacturing and the lost-wax metal casting technique assessed using the triple-scan protocol.

    Science.gov (United States)

    Dahl, Bjørn E; Dahl, Jon E; Rønold, Hans J

    2018-02-01

    Suboptimal adaptation of fixed dental prostheses (FDPs) can lead to technical and biological complications. It is unclear if the computer-aided design/computer-aided manufacturing (CAD/CAM) technique improves adaptation of FDPs compared with FDPs made using the lost-wax and metal casting technique. Three-unit FDPs were manufactured by CAD/CAM based on digital impression of a typodont model. The FDPs were made from one of five materials: pre-sintered zirconium dioxide; hot isostatic pressed zirconium dioxide; lithium disilicate glass-ceramic; milled cobalt-chromium; and laser-sintered cobalt-chromium. The FDPs made using the lost-wax and metal casting technique were used as reference. The fit of the FDPs was analysed using the triple-scan method. The fit was evaluated for both single abutments and three-unit FDPs. The average cement space varied between 50 μm and 300 μm. Insignificant differences in internal fit were observed between the CAD/CAM-manufactured FDPs, and none of the FPDs had cement spaces that were statistically significantly different from those of the reference FDP. For all FDPs, the cement space at a marginal band 0.5-1.0 mm from the preparation margin was less than 100 μm. The milled cobalt-chromium FDP had the closest fit. The cement space of FDPs produced using the CAD/CAM technique was similar to that of FDPs produced using the conventional lost-wax and metal casting technique. © 2017 Eur J Oral Sci.

  8. Study protocol: cluster randomised controlled trial to assess the clinical and cost effectiveness of a staff training intervention in inpatient mental health rehabilitation units in increasing service users' engagement in activities.

    Science.gov (United States)

    Killaspy, Helen; Cook, Sarah; Mundy, Tim; Craig, Thomas; Holloway, Frank; Leavey, Gerard; Marston, Louise; McCrone, Paul; Koeser, Leonardo; Arbuthnott, Maurice; Omar, Rumana Z; King, Michael

    2013-08-28

    This study focuses on people with complex and severe mental health problems who require inpatient rehabilitation. The majority have a diagnosis of schizophrenia whose recovery has been delayed due to non-response to first-line treatments, cognitive impairment, negative symptoms and co-existing problems such as substance misuse. These problems contribute to major impairments in social and everyday functioning necessitating lengthy admissions and high support needs on discharge to the community. Engagement in structured activities reduces negative symptoms of psychosis and may lead to improvement in function, but no trials have been conducted to test the efficacy of interventions that aim to achieve this. This study aims to investigate the clinical and cost-effectiveness of a staff training intervention to increase service users' engagement in activities. This is a single-blind, two-arm cluster randomised controlled trial involving 40 inpatient mental health rehabilitation units across England. Units are randomised on an equal basis to receive either standard care or a "hands-on", manualised staff training programme comprising three distinct phases (predisposing, enabling and reinforcing) delivered by a small team of psychiatrists, occupational therapists, service users and activity workers. The primary outcome is service user engagement in activities 12 months after randomisation, assessed using a standardised measure. Secondary outcomes include social functioning and costs and cost-effectiveness of care. The study will provide much needed evidence for a practical staff training intervention that has potential to improve service user functioning, reducing the need for hospital treatment and supporting successful community discharge. The trial is registered with Current Controlled Trials (Ref ISRCTN25898179).

  9. Converting multilevel nonclassicality into genuine multipartite entanglement

    Science.gov (United States)

    Regula, Bartosz; Piani, Marco; Cianciaruso, Marco; Bromley, Thomas R.; Streltsov, Alexander; Adesso, Gerardo

    2018-03-01

    Characterizing genuine quantum resources and determining operational rules for their manipulation are crucial steps to appraise possibilities and limitations of quantum technologies. Two such key resources are nonclassicality, manifested as quantum superposition between reference states of a single system, and entanglement, capturing quantum correlations among two or more subsystems. Here we present a general formalism for the conversion of nonclassicality into multipartite entanglement, showing that a faithful reversible transformation between the two resources is always possible within a precise resource-theoretic framework. Specializing to quantum coherence between the levels of a quantum system as an instance of nonclassicality, we introduce explicit protocols for such a mapping. We further show that the conversion relates multilevel coherence and multipartite entanglement not only qualitatively, but also quantitatively, restricting the amount of entanglement achievable in the process and in particular yielding an equality between the two resources when quantified by fidelity-based geometric measures.

  10. IAEA to implement Safeguards Additional Protocols in the EU

    International Nuclear Information System (INIS)

    2004-01-01

    Full text: IAEA Director General Mohamed ElBaradei welcomed the entry into force today of the Additional Protocols for 15 States of the European Union - France, the United Kingdom and the 13 non-nuclear weapon States of the EU - and the European Atomic Energy Community (EURATOM). The Protocols, which provide the Agency with better tools to verify compliance with nuclear non-proliferation commitments, entered into force when the European Commission informed the Agency that EURATOM's own requirements for entry into force had been met. The 15 States had provided similar notifications over the past years since signing the Protocols in 1998. The simultaneous entry into force of Additional Protocols for the 15 EU States is 'a very positive development and a milestone in our efforts to strengthen the verification regime', said Dr. ElBaradei. 'In my view, the Additional Protocol should become the standard for verification under the Treaty on the Non-Proliferation of Nuclear Weapons (NPT).' He added that the Agency had been preparing for the entry into force of the EU protocols and was confident that, in co-operation with the 15 States and EURATOM, it would be able to ensure effective and efficient implementation in the EU States. The Model Additional Protocol was developed following the discovery of Iraq's clandestine nuclear weapons programme to ensure that the IAEA is given the information and access it needs for timely discovery of any similar activities in States that have pledged not to use nuclear material and activities for weapons purposes. In the past year, Additional Protocols entered into force for 22 countries, and the Agency will now implement Additional Protocols in 58 States, which includes the 15 EU States. The 10 countries joining the EU on 1 May 2004 - seven of which already have brought into force Additional Protocols to their respective safeguards agreements - are expected to gradually accede to the Safeguards Agreement and Additional Protocol covering

  11. PV source based high voltage gain current fed converter

    Science.gov (United States)

    Saha, Soumya; Poddar, Sahityika; Chimonyo, Kudzai B.; Arunkumar, G.; Elangovan, D.

    2017-11-01

    This work involves designing and simulation of a PV source based high voltage gain, current fed converter. It deals with an isolated DC-DC converter which utilizes boost converter topology. The proposed converter is capable of high voltage gain and above all have very high efficiency levels as proved by the simulation results. The project intends to produce an output of 800 V dc from a 48 V dc input. The simulation results obtained from PSIM application interface were used to analyze the performance of the proposed converter. Transformer used in the circuit steps up the voltage as well as to provide electrical isolation between the low voltage and high voltage side. Since the converter involves high switching frequency of 100 kHz, ultrafast recovery diodes are employed in the circuitry. The major application of the project is for future modeling of solar powered electric hybrid cars.

  12. RISK ANALYSIS FOR SHIP CONVERTING PROJECT ACCOMPLISHMENT (Case study of KRI KP Converting Project

    Directory of Open Access Journals (Sweden)

    Dimas Endro W

    2013-10-01

    Full Text Available Ship converting has become as prospective activity in ship building area. Operational and economical aspect are the most dominant rationale. Baseon a new fuction of converted ship, a task list which contain several jobs that must be done is listed. This accomplishment schedule not only contain a task list, but also duration for certain job title. In practical apllication job duration is maintained based on experience of project manager.  Further more, total accomplish duration is setted as time accomplishment for the project. This setted time has become reference for the project bid. Occasionaly, if accomplishment time which offered is strict, than schedule slip become as potencial nightmare. For this situation, project manager has had a cristal clearconsideration to select a proper decision wheter he will take the tender offer or not. practically, project mananger has layed on his experience to handle previous project and face  penalty if the project delayed. This paper focussed on how to measure tender offer based on risk analysis, specially for converted ship tender which has a strike time accomplishment.A new application method to analysis proposed tender based on time and penalty parameter has become a topic of this paper.

  13. Grid Connected Solar PV System with SEPIC Converter Compared with Parallel Boost Converter Based MPPT

    Directory of Open Access Journals (Sweden)

    T. Ajith Bosco Raj

    2014-01-01

    Full Text Available The main objective of this work is to study the behaviour of the solar PV systems and model the efficient Grid-connected solar power system. The DC-DC MPPT circuit using chaotic pulse width modulation has been designed to track maximum power from solar PV module. The conversion efficiency of the proposed MPPT system is increased when CPWM is used as a control scheme. This paper also proposes a simplified multilevel (seven level inverter for a grid-connected photovoltaic system. The primary goal of these systems is to increase the energy injected to the grid by keeping track of the maximum power point of the panel, by reducing the switching frequency, and by providing high reliability. The maximum power has been tracked experimentally. It is compared with parallel boost converter. Also this model is based on mathematical equations and is described through an equivalent circuit including a PV source with MPPT, a diode, a series resistor, a shunt resistor, and dual boost converter with active snubber circuit. This model can extract PV power and boost by using dual boost converter with active snubber. By using this method the overall system efficiency is improved thereby reducing the switching losses and cost.

  14. Parallel resonant converter with LLC-type commutation

    Science.gov (United States)

    Lee, C. Q.; Liu, Rui; Batarseh, Issa

    1989-11-01

    It is shown that by using a proper transformation of state variables, the third-order system of the parallel resonant converter (PRC) with LLC-type commutation can be analyzed by means of a two-dimensional state-plane diagram. A set of characteristic curves which can be used for the converter design is derived from the analysis. It is shown from these curves that the converter possesses more desirable features than the conventional PRC.

  15. State-Trajectory Analysis and Control of LLC Resonant Converters

    OpenAIRE

    Feng, Weiyi

    2013-01-01

    With the fast development of communication systems, computers and consumer electronics, the power supplies for telecoms, servers, desktops, laptops, flat-panel TVs, LED lighting, etc. are required for more power delivery with smaller spaces. The LLC resonant converter has been widely adopted for these applications due to the advantages in high efficiency, high power density and holdup time operation capability.However, unlike PWM converters, the control of the LLC resonant converter is much m...

  16. Distance relay performance in future converter dominated power systems

    OpenAIRE

    Sarkar, Moumita; Jia, Jundi; Yang, Guangya

    2017-01-01

    Increasing penetration of converter-based generations in power system has led to new system challenges. Short circuit power response from converter-based generations is different from that of traditional synchronous generators. Power electronic converters can be designed for over-current only up to 1.1-1.25 times of its nominal value. Low availability of short circuit power can cause many challenges such as misoperation of distance relays. The aim of this paper is to investigate the effect of...

  17. Contingent Conversion Convertible Bond: New avenue to raise bank capital

    OpenAIRE

    DI GIROLAMO FRANCESCA; CAMPOLONGO FRANCESCA; DE SPIEGELEER JAN; SCHOUTENS WIM

    2016-01-01

    This paper provides an in-depth analysis of the structuring and the pricing of an innovative financial market product. This instrument is called a contingent conversion convertible bond or "CoCoCo". This hybrid bond is itself a combination of two other hybrid instruments: a contingent convertible ("CoCo") and a convertible bond. This combination introduces more complexity in the structure but it also allows investors to profit from strong share price performances. This upside potential is add...

  18. Systematic risk variations (beta) convertible debenture brazilian companies

    OpenAIRE

    Renata Drumond Pinto Coelho Antonino; Wagner Moura Lamounier; Roberto Kaehler de Albuquerque Maranhão

    2010-01-01

    purpose of this article is to analyze the impact of issuing convertible debentures on the systematic risk of Brazilian companies. Some applied researches in the U.S. capital market (STEIN, 1992; LEWIS et al, 2002; RAI, 2005) indicate that convertible debentures may be used as an alternative financing source when adverse selection problem makes stock issuing unattractive financing source. The analysis of Brazilian companies that issued convertible debentures recorded in the period from 1998 to...

  19. Optimizing design of converters using power cycling lifetime models

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Ørndrup; Munk-Nielsen, Stig

    2015-01-01

    Converter power cycling lifetime depends heavily on converter operation point. A lifetime model of a single power module switched mode power supply with wide input voltage range is shown. A lifetime model is created using a power loss model, a thermal model and a model for power cycling capability...... with a given mission profile. A method to improve the expected lifetime of the converter is presented, taking into account switching frequency, input voltage and transformer turns ratio....

  20. Large-signal stability analysis of PWM converters

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, P.T. [Philips Labs., Briarcliff Manor, NY (United States); Cho, B.H. [Seoul National Univ. (Korea, Republic of). Dept. of Electrical Engineering

    1995-12-31

    Investigation of the effects of existing nonlinearities on the stability of PWM converters is performed. The bilinear structure, the duty cycle saturation, and the opamp saturation are the principal nonlinearities in PWM converters. These nonlinearities are incorporated in the large-signal analytical models of PWM converters, and the basic input-output stability theory is applied to analyze their stability. Design and optimization of the small-signal loop gains to counteract the undesirable nonlinear effects are also discussed.