WorldWideScience

Sample records for unit picu design

  1. Reduction of adult fingers visualized on pediatric intensive care unit (PICU) chest radiographs after radiation technologist and PICU staff radiation safety education

    Energy Technology Data Exchange (ETDEWEB)

    Tynan, J.R.; Duncan, M.D.; Burbridge, B.E., E-mail: jentynan@hotmail.com [Univ. of Saskatchewan, Royal Univ. Hospital, Dept. of Medical Imaging, Saskatoon, Saskatchewan (Canada)

    2009-10-15

    A recent publication from our centre revealed a disturbing finding of a significant incidence of adult fingers seen on the pediatric intensive care unit (PICU) chest radiographs. This is inappropriate occupational exposure to diagnostic radiation. We hypothesized that the incidence of adult fingers on PICU chest radiographs would decline after radiation safety educational seminars were given to the medical radiation technologists and PICU staff. The present study's objectives were addressed by using a pretest-posttest design. Two cross-sectional PICU chest radiograph samples, taken before and after the administration of radiation safety education for our medical radiation technologists and PICU staff, were compared by using a {chi}{sup 2} test. There was a 61.2% and 76.9% reduction in extraneous adult fingers, directly exposed to the x-ray beam and those seen in the coned regions of the film, respectively, on PICU chest radiographs (66.7% reduction overall). This reduction was statistically significant ({chi}2 = 20.613, P < .001). Limiting unnecessary occupational radiation exposure is a critical issue in radiology. There was a statistically and clinically significant association between radiation safety education and the decreased number of adult fingers seen on PICU chest radiographs. This study provides preliminary evidence in favour of the benefit of radiation safety seminars. (author)

  2. PICU Up!: Impact of a Quality Improvement Intervention to Promote Early Mobilization in Critically Ill Children.

    Science.gov (United States)

    Wieczorek, Beth; Ascenzi, Judith; Kim, Yun; Lenker, Hallie; Potter, Caroline; Shata, Nehal J; Mitchell, Lauren; Haut, Catherine; Berkowitz, Ivor; Pidcock, Frank; Hoch, Jeannine; Malamed, Connie; Kravitz, Tamara; Kudchadkar, Sapna R

    2016-12-01

    To determine the safety and feasibility of an early mobilization program in a PICU. Observational, pre-post design. PICU in a tertiary academic hospital in the United States. Critically ill pediatric patients admitted to the PICU. This quality improvement project involved a usual-care baseline phase, followed by a quality improvement phase that implemented a multicomponent, interdisciplinary, and tiered activity plan to promote early mobilization of critically ill children. Data were collected and analyzed from July to August 2014 (preimplementation phase) and July to August 2015 (postimplementation). The study sample included 200 children 1 day through 17 years old who were admitted to the PICU and had a length of stay of at least 3 days. PICU Up! implementation led to an increase in occupational therapy consultations (44% vs 59%; p = 0.034) and physical therapy consultations (54% vs 66%; p = 0.08) by PICU day 3. The median number of mobilizations per patient by PICU day 3 increased from 3 to 6 (p < 0.001). More children engaged in mobilization activities after the PICU Up! intervention by PICU day 3, including active bed positioning (p < 0.001), and ambulation (p = 0.04). No adverse events occurred as a result of early mobilization activities. The most commonly reported barriers to early mobilization after PICU Up! implementation was availability of appropriate equipment. The program was positively received by PICU staff. Implementation of a structured and stratified early mobilization program in the PICU was feasible and resulted in no adverse events. PICU Up! increased physical therapy and occupational therapy involvement in the children's care and increased early mobilization activities, including ambulation. A bundled intervention to create a healing environment in the PICU with structured activity may have benefits for short- and long-term outcomes of critically ill children.

  3. Incidental sinusitis in a pediatric intensive care unit

    Science.gov (United States)

    Moore, Brooke M.; Kurachek, Stephen C.; Blumberg, Karen; Laguna, Theresa A.; Liu, Meixia; Olson, Erin E.

    2013-01-01

    Objective Intubation is a risk factor for nosocomial sinusitis in adult intensive care patients. Sinusitis in intubated adults can be an occult cause of fever. In children nasal intubation may be associated with a greater risk of sinusitis. No pediatric study has determined the incidence of nosocomial sinusitis in the pediatric intensive care unit (PICU) setting. We hypothesized that within a subset of patients who had head CT imaging: (1) the incidence of sinusitis in PICU patients exceeds the incidence in non-PICU patients; (2) the incidence of sinusitis is greater in PICU patients with a tube (nasotracheal, nasogastric, orotracheal, or orogastric); and (3) nasal tubes confer an increased risk for sinusitis compared to oral tubes. Design Retrospective chart review Setting Independent not-for-profit pediatric healthcare system Patients PICU and non-PICU (inpatients hospitalized on medical-surgical wards) patients referred for head CT Interventions None Measurements and Main Results CT images were evaluated for the presence of a tube and sinusitis. Images were scored using the Lund-MacKay (LM) staging system. Sinusitis was defined as a LM score >3.5. 596 patients were studied; 395 (66.3%) PICU. 197 (50%) PICU versus 69 (34.3%) non-PICU patients had sinusitis (p sinusitis versus 88/248 (35.9%) of those without a tube present (p sinusitis based on tube location (p=0.218). Younger age or the presence of a tube increased the probability of sinusitis (p sinus disease had evidence of sinusitis. This finding raises the concern that sinusitis in PICU patients is common and likely should be considered in the differential diagnosis of fever in PICU patients. PMID:21283043

  4. "Cohabitation" between NICU and PICU.

    Science.gov (United States)

    Biban, Paolo; Spaggiari, Stefania

    2011-10-01

    Neonatal and paediatric intensive care are usually provided in distinct units, characterized by highly specialized staffs dedicated either to critically ill newborns (NICUs) or to critically ill children (PICUs). However, such a model may be not suitable or even applicable to all medical organisations or to different local needs. Actually, in Europe there are several PICUs which routinely provide care also to neonatal patients, including extremely preterm infants. Conversely, there are many NICUs which occasionally, or systematically, admit also young infants and toddlers. Whilst many aspects of modern neonatal care do resemble those routinely used in the paediatric intensive care setting, several clinical issues are unique to each respective sector and cannot be easily translated to the other one. In order to guarantee the best quality of care, NICU doctors and nurses should acquire adequate competence and skills, by means of focused multidisciplinary training programmes, as well as extensive exposure to a wide paediatric case mix.

  5. [Understanding a hospitalized, school-aged child's stress in the PICU: the application of picture books in nursing care].

    Science.gov (United States)

    Wang, Pei-Ju; Feng, Jui-Ying

    2013-06-01

    Hospitalization in the pediatric intensive care unit (PICU) can be a very stressful and sometimes traumatic experience for school-aged children due to illness, painful procedures, unfamiliar environment, and separation from family. We incorporated picture books into PICU nursing care to explore the stress response in a school-aged child with compartment syndrome who was hospitalized in the PICU. Observation, interview and communication with the patient were used to assess her psychological reactions and emotional and behavioral responses to stress related to hospitalization and medical treatment. Autonomy and control were provided and strengthened by giving the patient choices and purposive life plans. Picture books were used to establish rapport and help the patient express her feelings, needs, and desires for parental love and company. This case report highlights the importance of nurses' awareness of children's stresses and needs during hospitalization in the PICU as well as the value of picture books or other age-appropriate tools for this patient population.

  6. PICU EXTUBATION FAILURE: THE ROLE OF NEUROMUSCULAR DISORDERS

    Directory of Open Access Journals (Sweden)

    N. Billan MD,

    2007-02-01

    Full Text Available ObjectiveNeuromuscular disorders (diseases of the motor unit, can cause respiratory problems such as impaired cough reflex, chest deformity, recurrent pneumonia and acute respiratory failure; these are the worst most common complications of these diseases and the leading cause of death in such patients (1, 2. Their management hence, very often, entails admission to the Pediatric Intensive Care Unit (PICU (3,4 and during this phase, endotracheal intubation is almost always necessary, to maintain the patency of airways and to apply Positive Pressure Ventilation (PPV. However, endotracheal intubation is always temporary, and its success or failure depends on the timely decision of its termination to restore the normal respiration or to avoid the risk of recurring respiratory failure (5, 6. We designed this study to evaluate the role of neuromuscular disorders in causing extubation failure as compared to that of other risk factors.Materials & MethodsIn an analytical cross-sectional study, the risk factors of reintubation and duration of mechanical ventilation in two groups of 30 patients each, was compared, the first successful extubation and the second with extubation failure.ResultsNeuromuscular disorders (including Spinal Muscular Atrophy, Guillain- Barre' Syndrome, Congenital Myopathies and Muscular Dystrophies were the main underlying diseases in extubation-failure group (P= 0.0002. Hypercapnia (PaCO2>50mmHg was shown to be the most common cause of both the first intubation (P=0.001 and reintubation (P=0.004 in the group of patients who failed extubation. The mean duration of intubation and mechanical ventilation was longer in patients with neuromuscular disorders who had extubation failure (P= 0.01.ConclusionThis study showed that, as underlying problems, neuromuscular disorders are the most common causes of prolonged intubation which defeat weaning from the ventilator and result in reintubation by inducing hypercapnia. Therefore the weaning

  7. Danish parents' experiences when their newborn or critically ill child is transferred to the PICU - a qualitative study

    DEFF Research Database (Denmark)

    Hall, Elisabeth

    2005-01-01

    The aim of this study was to describe Danish parents' experiences when their newborn or small child was critically ill. Thirteen parents were interviewed. Data were analyzed using qualitative content analysis. The child's transfer to the paediatric intensive care unit (PICU) meant either help or ...... their child's transfer to and from the PICU. Critical care nurses have to discuss the policy of family-centred care.......The aim of this study was to describe Danish parents' experiences when their newborn or small child was critically ill. Thirteen parents were interviewed. Data were analyzed using qualitative content analysis. The child's transfer to the paediatric intensive care unit (PICU) meant either help...... or death for the parents. The back transfer was experienced as joy and despair. The parents had confidence in most nurses, and they were kind, helpful, informative and capable. Less capable and distressed nurses made the parents feel uncomfortale and insecure. Parents need help and support during...

  8. Identifying Barriers to Delirium Screening and Prevention in the Pediatric ICU: Evaluation of PICU Staff Knowledge.

    Science.gov (United States)

    Flaigle, Melanie Cooper; Ascenzi, Judy; Kudchadkar, Sapna R

    2016-01-01

    Delirium in the pediatric intensive care unit (PICU) setting is often unrecognized and undertreated. The importance of screening and identification of ICU delirium has been identified in both adult and pediatric literature. Delirium increases ICU morbidity, length of mechanical ventilation and length of stay. The objective of this study was to determine the current knowledge level about delirium and its risk factors among pediatric critical care nurses through a short questionnaire. We hypothesized that before a targeted educational intervention, PICU care providers do not have an adequate knowledge base for accurate screening and diagnosis of delirium in critically ill children. A 17 question online survey was given to all nurses in a tertiary 36-bed PICU to assess current knowledge about delirium in children. The response rate was 73% (105/143). When asked to identify the correct way to diagnose pediatric delirium, 11.4% of nurses surveyed (12/105) incorrectly believed that Glasgow Coma Score is the appropriate screening tool. A large proportion of respondents (40/105) believed that benzodiazepines are helpful in treatment of delirium. The results of the survey identified specific knowledge gaps about risk factors and treatment of pediatric delirium in the critically ill child. There is a critical need for education about pediatric delirium and its risk factors among PICU staff prior to unit-wide implementation of a delirium screening and prevention program, specifically with regards to screening methods and pharmacologic risk factors. These results are likely generalizable to all physicians, nurses and staff who care for critically ill children.

  9. Hyponatremia in a child with tuberculous meningitis in PICU: Cerebral salt wasting syndrome

    Directory of Open Access Journals (Sweden)

    Mehmet Boşnak

    2009-01-01

    Full Text Available Cerebral salt wasting syndrome (CSW has been reported in cases with subarachnoid haemorrhage, infections, head injury, brain tumours, trans-sphenoidal pituitary surgery, and neurosurgery. It is characterized by extracellular fluid depletion and hyponatraemia caused by progressive natriuresis with concomitant diuresis.The relationship between tuberculous menengitis and CSW in children has been desciribed rarely. We describe a case of CSW in an eight years old child with tuberculous meningitis in Pediatric Intensive Care Unit (PICU whose main biochemical findings were low serum sodium, excessive urine sodium loss and clinical evidence of a contracted extracellular fluid volume.It is essential that in any child with hyponatremia and meningitis in PICU, an evaluation to be undertaken to differentiate between syndrome of inappropriate antidiuretic hormone secretion (SIADH and CSW. A wrong diagnosis might lead to inappropriate fluid restriction and worsen the hypovolemia in children with CSW. Supplements of sodium chloride and mineralocorticoids may be useful in managing children with CSW. PICU professionals must be aware of the clinical and laboratory features that distinguish CSW from SIADH.

  10. MORTALITY RISK ASSESSMENT IN PICU USING PRISM-III-24 SCORE

    Directory of Open Access Journals (Sweden)

    Harilal Naik

    2014-11-01

    Full Text Available OBJECTIVE: Assessment of risk of mortality using PRISM III-24 score in children admitted to PICU of Basaweshwara Teaching and General Hospital, attached to Mahadevappa Rampure Medical College, Gulbarga. DESIGN: Prospective cohort study. Setting: PICU of BTGH, Gulbarga. METHODS: 404 patients who had been admitted consecutively to the PICU during a period of 12 months (July 2011 to June 2012 were studied. PRISM III-24 score was calculated. Hospital outcome was recorded as survived/expired. Calibration and discrimination of the model was calculated by Hosmer-Lemeshow goodness-of-fit test and Area under the ROC Curve. The association between r (empirical function and PRISM III-24 score was assessed by Binary Logistic Regression method. RESULTS: Out of 404 patients, 363 (89.85% survived and 41 (10.15% expired. Males formed the majority (227/404. CNS cases (n=118, 29.2% constituted the majority. Mean age, length of hospitalization, and mean PRISM III-24 score were 59.22±51.12 months, 99.84±91.61 hours, and 4.92±7.74 (range 0-36. The test was well designed for the study (goodness-of-fit value P-value 0.186. ROC analysis indicated a strong predictive power for the PRISM III-24 (AUC 0.936. The observed (O mortality rate was 10.15% and the expected (E mortality rate was 10.12% with an O/E ratio of 1.003. CONCLUSION: PRISM III-24 score is a good predictor of mortality in PICU patients under Indian circumstances. The PRISM III-24 scoring system was highly calibrated in our institute.

  11. Design of hydraulic recuperation unit

    Directory of Open Access Journals (Sweden)

    Jandourek Pavel

    2016-01-01

    Full Text Available This article deals with design and measurement of hydraulic recuperation unit. Recuperation unit consist of radial turbine and axial pump, which are coupled on the same shaft. Speed of shaft with impellers are 6000 1/min. For economic reasons, is design of recuperation unit performed using commercially manufactured propellers.

  12. Communication With Limited English-Proficient Families in the PICU.

    Science.gov (United States)

    Zurca, Adrian D; Fisher, Kiondra R; Flor, Remigio J; Gonzalez-Marques, Catalina D; Wang, Jichuan; Cheng, Yao I; October, Tessie W

    2017-01-01

    Health care disparities have been described for children of limited English-proficient (LEP) families compared with children of English-proficient (EP) families. Poor communication with the medical team may contribute to these worse health outcomes. Previous studies exploring communication in the PICU have excluded LEP families. We aimed to understand communication experiences and preferences in the 3 primary communication settings in the PICU. We also explored LEP families' views on interpreter use in the PICU. EP and Spanish-speaking LEP families of children admitted to the PICU of a large tertiary pediatric hospital completed surveys between 24 hours and 7 days of admission. A total of 161 of 184 families were surveyed (88% response rate); 52 were LEP and 109 EP. LEP families were less likely to understand the material discussed on rounds (odds ratio [OR] 0.32, 95% confidence interval [CI] 0.11-0.90), to report that PICU nurses spent enough time speaking with them (OR 0.15, 95% CI 0.05-0.41), and to report they could rely on their nurses for medical updates (OR 0.07, 95% CI 0.02-0.25) controlling for covariates, such as education, insurance type, presence of a chronic condition, PICU length of stay, and mortality index. LEP families reported 53% of physicians and 41% of nurses used an interpreter "often." Physician and nurse communication with LEP families is suboptimal. Communication with LEP families may be improved with regular use of interpreters and an increased awareness of the added barrier of language proficiency. Copyright © 2017 by the American Academy of Pediatrics.

  13. Patient origin is associated with duration of endotracheal intubation and PICU length of stay for children with status asthmaticus.

    Science.gov (United States)

    Shibata, Shinpei; Khemani, Robinder G; Markovitz, Barry

    2014-01-01

    To describe intubation practices and duration of mechanical ventilation in children with status asthmaticus admitted from emergency departments (ERs) to pediatric intensive care units (PICUs). Retrospective cohort study using the Virtual PICU Performance System database (VPS, LLC) of children with status asthmaticus admitted to a participating PICU between December 2003 and September 2006. The primary outcome measure was intubation prior to intensive care unit (ICU) admission. Secondary outcomes included length of intubation and medical length of stay. Thirty-five PICUs in the United States. Children who were intubated and mechanically ventilated during their ICU stay for asthma and were admitted from an ER. A total of 4051 patients with status asthmaticus were identified. Intubation data were available from 35 of the 53 centers. Of all, 187 children were intubated for asthma, of which 157 were admitted from an ER and had complete data. Of all, 85 patients were from community hospital ERs and 72 were from the institution's own ER. In all, 115 (73%) patients were intubated prior to ICU admission and 42 (27%) patients were intubated after PICU admission. Of patients who received mechanical ventilation for status asthmaticus and were intubated prior to PICU admission, a greater proportion were intubated at community hospital ERs than in the institutions' own ERs. Eighty-five percent of the patients from community hospital ERs were intubated prior to PICU admission as opposed to 60% from institution's own ERs (P = .0004). However, median duration of intubation and PICU stay from community hospital ERs was significantly shorter than from the hospitals' own ERs (25 vs 42 hours P = .011; 57 vs 98 hours P = .0013, respectively). Logistic regression analysis revealed that after controlling for the effects of age, race, gender, and a revised version of the Paediatric Index of Mortality score of patients who were admitted for status asthmaticus and required mechanical

  14. The Amsterdam Studies of Acute Psychiatry - II (ASAP-II: a comparative study of psychiatric intensive care units in the Netherlands

    Directory of Open Access Journals (Sweden)

    van Venrooij Janine

    2009-09-01

    Full Text Available Abstract Background The number of patients in whom mental illness progresses to stages in which acute, and often forced treatment is warranted, is on the increase across Europe. As a consequence, more patients are involuntarily admitted to Psychiatric Intensive Care Units (PICU. From several studies and reports it has become evident that important dissimilarities exist between PICU's. The current study seeks to describe organisational as well as clinical and patient related factors across ten PICU's in and outside the Amsterdam region, adjusted for or stratified by level of urbanization. Method/Design This paper describes the design of the Amsterdam Studies of Acute Psychiatry II (ASAP-II. This study is a prospective observational cohort study comparing PICU's in and outside the Amsterdam region on various patient characteristics, treatment aspects and recovery related variables. Dissimilarities were measured by means of collecting standardized forms which were filled out in the framework of care as usual, by means of questionnaires filled out by mental health care professionals and by means of extracting data from patient files for every consecutive patient admitted at participating PICU's during a specific time period. Urbanization levels for every PICU were calculated conform procedures as proposed by the Dutch Central Bureau for Statistics (CBS. Discussion The current study may provide a deeper understanding of the differences between psychiatric intensive care units that can be used to promote best practice and benchmarking procedures, and thus improve the standard of care.

  15. The Effect of Family Presence on Rounding Duration in the PICU.

    Science.gov (United States)

    Gupta, Priya R; Perkins, R Serene; Hascall, Rebecca L; Shelak, Carolyn F; Demirel, Shaban; Buchholz, Mark T

    2017-02-01

    The incorporation of family-centered rounds has become standard in PICUs across the United States. We compared rounding times in our institution, with and without family members present, to determine the effect on total rounding time and work flow. This observational study of a convenience sample was conducted over a 17-month period (May 2014-October 2015), accounting for typical seasonal variation in the PICU. The individual patient rounding times for 2657 encounters were recorded. The presence of family members, intubation status, physician assistant participation, interruptions during rounds, attending physician's full- or part-time status, and patient census were documented. The effect of family presence on per-patient rounding time was analyzed, while controlling for influential variables. Family members were present during 1743 of 2657 (66%) rounding encounters. The average per-patient rounding time with and without family members present was 8.6 minutes and 7.3 minutes, respectively, a difference of 1.3 minutes per patient. In statistical models that accounted for other influential variables, the presence of family members was associated with a highly significant (20.4%, P family members increases per-patient rounding times in the PICU. Family presence on rounds may have benefits that outweigh the additional time required to complete each patient interaction. Copyright © 2017 by the American Academy of Pediatrics.

  16. Design of Dolos Armour Units

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Zhou

    1993-01-01

    The slender, complex types of armour units, such as Tetrapods and Dolosse are widely used. Many of the recent failures are such rubble mound breakwaters revealed that there is an imbalance between strength (structural integrity) of the units and the hydraulic stability (resistance to displacements......) of the armour layers. The paper deals only with dolos armour and presents the first design diagrammes and formulae where stresses from static, quasistatic and impact loads are implemented as well as the hydraulic stability. The dolos is treated as a multi shape unit where the thickness can be adjusted...

  17. Do PICU patients meet technical criteria for performing indirect calorimetry?

    Science.gov (United States)

    Beggs, Megan R; Garcia Guerra, Gonzalo; Larsen, Bodil M K

    2016-10-01

    Indirect calorimetry (IC) is considered gold standard for assessing energy needs of critically ill children as predictive equations and clinical status indicators are often unreliable. Accurate assessment of energy requirements in this vulnerable population is essential given the high risk of over or underfeeding and the consequences thereof. The proportion of patients and patient days in pediatric intensive care (PICU) for which energy expenditure (EE) can be measured using IC is currently unknown. In the current study, we aimed to quantify the daily proportion of consecutive PICU patients who met technical criteria to perform indirect calorimetry and describe the technical contraindications when criteria were not met. Prospective, observational, single-centre study conducted in a cardiac and general PICU. All consecutive patients admitted for at least 96 h were included in the study. Variables collected for each patient included age at admission, admission diagnosis, and if technical criteria for indirect calorimetry were met. Technical criteria variables were collected within the same 2 h each morning and include: provision of supplemental oxygen, ventilator settings, endotracheal tube (ETT) leak, diagnosis of chest tube air leak, provision of external gas support (i.e. nitric oxide), and provision of extracorporeal membrane oxygenation (ECMO). 288 patients were included for a total of 3590 patient days between June 2014 and February 2015. The main reasons for admission were: surgery (cardiac and non-cardiac), respiratory distress, trauma, oncology and medicine/other. The median (interquartile range) patient age was 0.7 (0.3-4.6) years. The median length of PICU stay was 7 (5-14) days. Only 34% (95% CI, 32.4-35.5%) of patient days met technical criteria for IC. For patients less than 6 months of age, technical criteria were met on significantly fewer patient days (29%, p technical criteria for IC on any day during their PICU stay. Most frequent reasons for

  18. Low cost balancing unit design

    Science.gov (United States)

    Golembiovsky, Matej; Dedek, Jan; Slanina, Zdenek

    2017-06-01

    This article deals with the design of a low-cost balancing system which consist of battery balancing units, accumulator pack units and coordinator unit with interface for higher level of battery management system. This solution allows decentralized mode of operation and the aim of this work is implementation of controlling and diagnostic mechanism into an electric scooter project realized at Technical university of Ostrava. In todays world which now fully enjoys the prime of electromobility, off-grid battery systems and other, it is important to seek the optimal balance between functionality and the economy side of BMS that being electronics which deals with secondary cells of batery packs. There were numerous sophisticated, but not too practical BMS models in the past, such as centralized system or standalone balance modules of individual cells. This article aims at development of standalone balance modules which are able to communicate with the coordinator, adjust their parameters and ensure their cells safety in case of a communication failure. With the current worldwide cutting cost trend in mind, the emphasis was put on the lowest price possible for individual component. The article is divided into two major categories, the first one being desing of power electronics with emphasis on quality, safety (cooling) and also cost. The second part describes development of a communication interface with reliability and cost in mind. The article contains numerous graphs from practical measurements. The outcome of the work and its possible future is defined in the conclusion.

  19. From intravenous to enteral ketogenic diet in PICU: A potential treatment strategy for refractory status epilepticus.

    Science.gov (United States)

    Chiusolo, F; Diamanti, A; Bianchi, R; Fusco, L; Elia, M; Capriati, T; Vigevano, F; Picardo, S

    2016-11-01

    Ketogenic diet (KD) has been used to treat refractory status epilepticus (RSE). KD is a high-fat, restricted-carbohydrate regimen that may be administered with different fat to protein and carbohydrate ratios (3:1 and 4:1 fat to protein and carbohydrate ratios). Other ketogenic regimens have a lower fat and higher protein and carbohydrate ratio to improve taste and thus compliance to treatment. We describe a case of RSE treated with intravenous KD in the Pediatric Intensive Care Unit (PICU). An 8-year-old boy was referred to the PICU because of continuous tonic-clonic and myoclonic generalized seizures despite several antiepileptic treatments. After admission he was intubated and treated with intravenous thiopental followed by ketamine. Seizures continued with frequent myoclonic jerks localized on the face and upper arms. EEG showed seizure activity with spikes on rhythmic continuous waves. Thus we decided to begin KD. The concomitant ileus contraindicated KD by the enteral route and we therefore began IV KD. The ketogenic regimen consisted of conventional intravenous fat emulsion, plus dextrose and amino-acid hyperalimentation in a 2:1 then 3:1 fat to protein and carbohydrate ratio. Exclusive IV ketogenic treatment, well tolerated, was maintained for 3 days; peristalsis then reappeared so KD was continued by the enteral route at 3:1 ratio. Finally, after 8 days and no seizure improvement, KD was deemed unsuccessful and was discontinued. Our experience indicates that IV KD may be considered as a temporary "bridge" towards enteral KD in patients with partial or total intestinal failure who need to start KD. It allows a prompt initiation of KD, when indicated for the treatment of severe diseases such as RSE. Copyright © 2016 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.

  20. Health-related quality of life after prolonged pediatric intensive care unit stay.

    LENUS (Irish Health Repository)

    Conlon, Niamh P

    2012-02-01

    OBJECTIVE: To investigate the long-term health-related quality of life (HRQOL) outcomes for patients requiring at least 28 days of pediatric intensive care. DESIGN: Retrospective cohort and prospective follow-up study. SETTING: A 21-bed pediatric intensive care unit (PICU) in a university-affiliated, tertiary referral pediatric hospital. PATIENTS: One hundred ninety-three patients who spent 28 days or longer in the PICU between January 1, 1997 and December 31, 2004. INTERVENTIONS: Quality of life was measured using the Pediatric Quality of Life Inventory (Peds QL 4.0) parent-proxy version at 2 to 10 yrs after discharge. The PedsQL 4.0 is a modular measure of HRQOL, which is reliable in children aged 2 to 18 yrs. It generates a total score and physical, emotional, social, school, and psychosocial subscores. MEASUREMENTS AND MAIN RESULTS: Of the 193 patients, 41 died during their PICU admission and 27 died between PICU discharge and follow-up. Quality of life questionnaires were posted to parents of 108 of the 125 survivors and 70 were returned completed. Forty children (57.1%) had scores indicating a normal quality of life, whereas 30 (42.9%) had scores indicating impaired HRQOL. Of these, 14 (20%) had scores indicating poor quality of life with ongoing disabling health problems requiring hospitalization or the equivalent. CONCLUSIONS: Our results indicate that, while long PICU stay is associated with significant mortality, the long-term HRQOL is normal for the majority of surviving children.

  1. End-of-life care decisions in the pediatric intensive care unit: roles professionals play

    Science.gov (United States)

    Michelson, Kelly Nicole; Patel, Rachna; Haber-Barker, Natalie; Emanuel, Linda; Frader, Joel

    2014-01-01

    Objective Describe the roles and respective responsibilities of pediatric intensive care unit (PICU) health care professionals (HCPs) in end-of-life care decisions faced by PICU parents. Design Retrospective qualitative study Setting University based tertiary care children’s hospital Participants Eighteen parents of children who died in the PICU and 48 PICU HCPs (physicians, nurses, social workers, child-life specialists, chaplains, and case managers). Interventions In depth, semi-structured focus groups and one-on-one interviews designed to explore experiences in end-of-life care decision making. Measurements and Main Results We identified end-of-life care decisions that parents face based on descriptions by parents and HCPs. Participants described medical and non-medical decisions addressed toward the end of a child’s life. From the descriptions, we identified seven roles HCPs play in end-of-life care decisions. The family supporter addresses emotional, spiritual, environmental, relational and informational family needs in a nondirective way. The family advocate helps families articulate their views and needs to HCPs. The information giver provides parents with medical information, identifies decisions or describes available options, and clarifies parents’ understanding. The general care coordinator helps facilitate interactions among HCPs in the PICU, among HCPs from different subspecialty teams, and between HCPs and parents. The decision maker makes or directly influences the defined plan of action. The end-of-life care coordinator organizes and executes functions occurring directly before, during and after dying/death. The point person develops a unique trusting relationship with parents. Conclusions Our results describe a framework for HCPs’ roles in parental end-of-life care decision making in the PICU that includes directive, value-neutral and organizational roles. More research is needed to validate these roles. Actively ensuring attention to these

  2. Pediatric Acute Respiratory Distress Sydnrome : Fluid Management in the PICU

    NARCIS (Netherlands)

    Ingelse, SA; Wösten-van Asperen, RM; Lemson, J; Daams, JG; Bem, R.A.; van Woensel, JB

    2016-01-01

    The administration of an appropriate volume of intravenous fluids, while avoiding fluid overload, is a major challenge in the pediatric intensive care unit. Despite our efforts, fluid overload is a very common clinical observation in critically ill children, in particular in those with pediatric acu

  3. Invasive fungal disease in PICU: epidemiology and risk factors.

    Science.gov (United States)

    Brissaud, Olivier; Guichoux, Julie; Harambat, Jerome; Tandonnet, Olivier; Zaoutis, Theoklis

    2012-02-22

    Candida and Aspergillus spp. are the most common agents responsible for invasive fungal infections in children. They are associated with a high mortality and morbidity rate as well as high health care costs. An important increase in their incidence has been observed during the past two decades. In infants and children, invasive candidiasis is five times more frequent than invasive aspergillosis. Candida sp. represents the third most common agent found in healthcare-associated bloodstream infections in children. Invasive aspergillosis is more often associated with hematological malignancies and solid tumors. Recommendations concerning prophylactic treatment for invasive aspergillosis have been recently published by the Infectious Diseases Society of America. Candida albicans is the main Candida sp. associated with invasive candidiasis in children, even if a strong trend toward the emergence of Candida non-albicans has been observed. The epidemiology and the risk factors for invasive fungal infections are quite different if considering previously healthy children hospitalized in the pediatric intensive care unit, or children with a malignancy or a severe hematological disease (leukemia). In children, the mortality rate for invasive aspergillosis is 2.5 to 3.5 higher than for invasive candidiasis (respectively 70% vs. 20% and 30%).

  4. Ethics of drug research in the pediatric intensive care unit.

    Science.gov (United States)

    Kleiber, Niina; Tromp, Krista; Mooij, Miriam G; van de Vathorst, Suzanne; Tibboel, Dick; de Wildt, Saskia N

    2015-02-01

    Critical illness and treatment modalities change pharmacokinetics and pharmacodynamics of medications used in critically ill children, in addition to age-related changes in drug disposition and effect. Hence, to ensure effective and safe drug therapy, research in this population is urgently needed. However, conducting research in the vulnerable population of the pediatric intensive care unit (PICU) presents with ethical challenges. This article addresses the main ethical issues specific to drug research in these critically ill children and proposes several solutions. The extraordinary environment of the PICU raises specific challenges to the design and conduct of research. The need for proxy consent of parents (or legal guardians) and the stress-inducing physical environment may threaten informed consent. The informed consent process is challenging because emergency research reduces or even eliminates the time to seek consent. Moreover, parental anxiety may impede adequate understanding and generate misconceptions. Alternative forms of consent have been developed taking into account the unpredictable reality of the acute critical care environment. As with any research in children, the burden and risk should be minimized. Recent developments in sample collection and analysis as well as pharmacokinetic analysis should be considered in the design of studies. Despite the difficulties inherent to drug research in critically ill children, methods are available to conduct ethically sound research resulting in relevant and generalizable data. This should motivate the PICU community to commit to drug research to ultimately provide the right drug at the right dose for every individual child.

  5. Design of the ERIS calibration unit

    Science.gov (United States)

    Dolci, Mauro; Valentini, Angelo; Di Rico, Gianluca; Esposito, Simone; Ferruzzi, Debora; Riccardi, Armando; Spanò, Paolo; Antichi, Jacopo

    2016-08-01

    The Enhanced Resolution Imager and Spectrograph (ERIS) is a new-generation instrument for the Cassegrain focus of the ESO UT4/VLT, aimed at performing AO-assisted imaging and medium resolution spectroscopy in the 1-5 micron wavelength range. ERIS consists of the 1-5 micron imaging camera NIX, the 1-2.5 micron integral field spectrograph SPIFFIER (a modified version of SPIFFI, currently operating on SINFONI), the AO module and the internal Calibration Unit (ERIS CU). The purpose of this unit is to provide facilities to calibrate the scientific instruments in the 1-2.5 micron and to perform troubleshooting and periodic maintenance tests of the AO module (e.g. NGS and LGS WFS internal calibrations and functionalities, ERIS differential flexures) in the 0.5 - 1 μm range. The ERIS CU must therefore be designed in order to provide, over the full 0.5 - 2.5 μm range, the following capabilities: 1) illumination of both the telescope focal plane and the telescope pupil with a high-degree of uniformity; 2) artificial point-like and extended sources onto the telescope focal plane, with high accuracy in both positioning and FWHM; 3) wavelength calibration; 4) high stability of these characteristics. In this paper the design of the ERIS CU, and the solutions adopted to fulfill all these requirements, is described. The ERIS CU construction is foreseen to start at the end of 2016.

  6. Is propofol a friend or a foe of the pediatric intensivist? Description of propofol use in a PICU*.

    Science.gov (United States)

    Koriyama, Hiromi; Duff, Jonathan P; Guerra, Gonzalo Garcia; Chan, Alice W

    2014-02-01

    The primary objective is to describe the practice patterns of nonprocedural propofol use in a single-center referral PICU. The secondary objective is to describe the rate of concordance of propofol use with the PICU local practice of a maximum mean rate of 4 mg/kg/hr and a maximum duration of 24 hours and to assess for signs and symptoms of propofol infusion syndrome. Retrospective descriptive cohort study. PICU of a tertiary care teaching hospital and referral hospital for the Western Canada. Children 1 month to 17 years old who received a nonprocedural propofol infusion between January 1, 2009, and December 31, 2009. None. Two hundred twenty-three infusions (representing 210 unique patients) were included in the study. The median average infusion rate (interquartile range) including boluses was 2.7 mg/kg/hr (1.9-3.6 mg/kg/hr), and the mean infusion duration (SD) was 10.3 hours (6.7 hr). Eighty-seven percent and 98% of infusions were concordant with PICU intensivists self-reported practice maximum rate and duration, respectively. No cases of propofol-related infusion syndrome or deaths associated with propofol infusions were identified. The use of propofol infusions was in concordance with PICU local practice, and propofol infusion syndrome did not developed in patients. In agreement with previous recommendations, propofol infusions in the PICU appear to be safe when limiting doses to 4 mg/kg/hr and for less than 24 hours; however, appropriate monitoring of adverse effects is still warranted due to absence of robust evidence.

  7. A pilot study about the burn out investigation of PICU medical and nursing personnel for a pediatric hospital

    Directory of Open Access Journals (Sweden)

    Paraskevi Pousderki

    2011-07-01

    Full Text Available The last decades, physicians' and nurses' burnout have been constituted a subject of many studies. Stress can be considerable in Pediatric Intensive Care Units (PICUs and Neonatal Intensive Care Units (NICUs, as the relationships between physicians/nursing personnel and the relatives can develop reacts of discomfort and depression to the professionals. Aim: The aim of this study was to investigate the existence or not of burnout in PICUs and NICUs in a pediatric hospital of Athens and the correlation of burnout with demographic and other social factors. Method and material: The study was conducted in a pediatric hospital of Athens. There were distributed 64 questionnaires to physicians and nursing staff and have been returned filled 48 (response rate, rr= 75%. The questionnaire that has been used was the Maslach burnout inventory (MBI, Maslach and Jackson 1984 and the statistical analysis has concluded not parametric tests using SPSS. Results: The professional burnout has been found in moderate levels as it seems by the means of the 3 dimensions of MBI. The mean scores of the emotional exhaustion were 22.02, the personal achievements 32.44 and the depersonalization 9.02. Significant statistical differences has been found between dimensions of MBI and sex (p=0,034, age (p=0,001, educational level (p=0,045, work department (p=0,004, work position (p=0,015, and years in the employment (p=0,025, at the hospital (p=0,008, in the department (p=0,018. Conclusion: As well as the professional burnout of physicians and nursing personnel working in PICU and NICU has been found between moderate to high levels, the managers of the hospitals should take it in account contributing in the improvement of personnel's quality of life in these particular departments.

  8. Delirium in Severely Ill Young Children in the Pediatric Intensive Care Unit (PICU)

    Science.gov (United States)

    Schieveld, Jan N. M.; Leentjens, Albert F. G.

    2005-01-01

    Delirium is a serious neuropsychiatric disorder frequently seen in severely ill adult and geriatric patients. The clinical picture in adults is well known, as are the negative prognostic implications of delirium on length of hospital stay, morbidity, and mortality (American Psychiatric Association, 1999); however, it is less appreciated that…

  9. Human-centered environment design in intensive care unit

    NARCIS (Netherlands)

    Li, Y.; Albayrak, A.; Goossens, R.H.M.; Xiao, D.; Jakimowicz, J.J.

    2013-01-01

    Because of high risk and instability of the patients in Intensive care unit(ICU), the design of ICU is very difficult. ICU design, auxiliary building design, lighting design, noise control and other aspects can also enhance its management. In this paper, we compare ICU design in China and Holland ba

  10. Decision Making in the PICU: An Examination of Factors Influencing Participation Decisions in Phase III Randomized Clinical Trials

    Directory of Open Access Journals (Sweden)

    Laura E. Slosky

    2014-01-01

    participate were not related to enrollment. Conclusion. Decisions to participate in research by surrogates of children in the PICU appear to relate to child demographics and subtleties in communication; however, no modifiable characteristics were related to increased participation, indicating that the informed consent process may not be compromised in this population.

  11. Shuttle Kit Freezer Refrigeration Unit Conceptual Design

    Science.gov (United States)

    Copeland, R. J.

    1975-01-01

    The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

  12. Adaptive subsystem aided design synthesis units REA on minicomputers

    Directory of Open Access Journals (Sweden)

    Yu. F. Zin'kovskii

    1986-04-01

    Full Text Available Questions of construction sub-aided design CAD integrated electronics units based on the principles of adaptation and self-tuning software and mathematical software for solving a specific problem.

  13. Perceptions of parents on satisfaction with care in the pediatric intensive care unit: the EMPATHIC study

    NARCIS (Netherlands)

    J.M. Latour (Jos); J.B. van Goudoever (Hans); H.J. Duivenvoorden (Hugo); N.A.M. van Dam (Nicolette); E. Dullaart (Eugenie); M.J.I.J. Albers (Marcel); C.W.M. Verlaat (Carin); E.M. van Vught (Elise); M. van Heerde (Marc); J.A. Hazelzet (Jan)

    2009-01-01

    textabstractAbstract: PURPOSE: To identify parental perceptions on pediatric intensive care-related satisfaction items within the framework of developing a Dutch pediatric intensive care unit (PICU) satisfaction instrument. METHODS: Prospective cohort study in tertiary PICUs at seven university

  14. Target value design: applications to newborn intensive care units.

    Science.gov (United States)

    Rybkowski, Zofia K; Shepley, Mardelle McCuskey; Ballard, H Glenn

    2012-01-01

    There is a need for greater understanding of the health impact of various design elements in neonatal intensive care units (NICUs) as well as cost-benefit information to make informed decisions about the long-term value of design decisions. This is particularly evident when design teams are considering the transition from open-bay NICUs to single-family-room (SFR) units. This paper introduces the guiding principles behind target value design (TVD)-a price-led design methodology that is gaining acceptance in healthcare facility design within the Lean construction methodology. The paper also discusses the role that set-based design plays in TVD and its application to NICUs.

  15. A Stellar Reference Unit Design Study for SIRTF

    DEFF Research Database (Denmark)

    Jørgensen, John Leif; Liebe, Carl Christian

    1996-01-01

    A design study for a stellar reference unit, or star tracker, for SIRTF was conducted in FY96 in conjunction with the Tracking Sensors Group of the Avionic Equipment Section of JPL. The resulting design was derived from the Oersted, autonomous, Advanced Stellar Compass, star tracker. The projecte...... of star tracker integration with the cryogenic telescope structure....

  16. Design Quality Indicator for Schools in the United Kingdom

    Science.gov (United States)

    PEB Exchange, 2006

    2006-01-01

    In December 2005, the United Kingdom launched a process for evaluating the design quality of primary and secondary school buildings. The Design Quality Indicator (DQI) for Schools is a tool that can assist stakeholders--teachers, parents, school governors, students, community members, local authority clients and building professionals--to achieve…

  17. A Stellar Reference Unit Design Study for SIRTF

    DEFF Research Database (Denmark)

    Jørgensen, John Leif; Liebe, Carl Christian

    1996-01-01

    A design study for a stellar reference unit, or star tracker, for SIRTF was conducted in FY96 in conjunction with the Tracking Sensors Group of the Avionic Equipment Section of JPL. The resulting design was derived from the Oersted, autonomous, Advanced Stellar Compass, star tracker. The projected...

  18. Developing a drug library for smart pumps in a pediatric intensive care unit.

    Science.gov (United States)

    Manrique-Rodríguez, Silvia; Sánchez-Galindo, Amelia; Fernández-Llamazares, Cecilia M; López-Herce, Jesús; García-López, Isabel; Carrillo-Álvarez, Angel; Sanjuro-Sáez, María

    2012-03-01

    The most serious medication errors occur during intravenous administration. The potential consequences are more serious the more critical and younger the patient. Smart pumps can help to prevent infusion-related programming errors, thanks to associated dose-limiting software known as "drug library". Drug libraries alert the user if pre-determined high dosage limits are exceeded or if entry is below pre-determined low dosage limits. To describe the process for developing a specific drug library for a pediatric intensive care unit (PICU) and the key factors for preventing programming errors. The study was performed by a multidisciplinary team consisting of a clinical pharmacist, a PICU pediatrician, and the chief nurse of the unit. The process of developing the drug library lasted seven months. A literature review was carried out to determine standard concentrations and accurate limits for intravenous administration of high-risk drugs. Alaris(®) syringe pumps and Guardrails(®) CQI v4.1 Event Reporter software were used. Several manufacturers offer smart pump technology. Users should be aware of differences in features, such as definition of parameters and associations between them, definition of safety limits, organization of the drug library, and data use. Our infusion pump technology covered 108 drugs. Compliance with the drug library was 85% and nurses' acceptance of the drug library was high as 94% would recommend implementation of this technology in other units. After nine months of implementation, several potentially harmful infusion-related programming errors were intercepted. Drug libraries are specifically designed for a particular hospital unit, and may condition the success in implementing this technology. Implementation of smart pumps proved effective in intercepting infusion-related programming errors after nine months of implementation in a PICU. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Optimization criteria for the design of orbital replacement units (ORUs)

    Science.gov (United States)

    Schulze, Manfred W.

    A reduction of life cycle costs of spacecraft or Space Station elements can be achieved by a modular build up which allows an in orbit replacement, maintenance, and service of functional units named Orbital Replacement Units (ORUs). The criteria for an optimal design for an ORU is presented. Requirements involving the user spacecraft configuration, the servicing vehicle, the handling by astronauts and remote manipulator system are considered.

  20. Parametric design studies of toroidal magnetic energy storage units

    Science.gov (United States)

    Herring, J. Stephen

    Superconducting magnetic energy storage (SMES) units have a number of advantages as storage devices. Electrical current is the input, output and stored medium, allowing for completely solid-state energy conversion. The magnets themselves have no moving parts. The round trip efficiency is higher than those for batteries, compressed air or pumped hydro. Output power can be very high, allowing complete discharge of the unit within a few seconds. Finally, the unit can be designed for a very large number of cycles, limited basically by fatigue in the structural components. A small systems code was written to produce and evaluate self-consistent designs for toroidal superconducting energy storage units. The units can use either low temperature or high temperature superconductors. The coils have D shape where the conductor and its stabilizer/structure is loaded only in tension and the centering forces are borne by a bucking cylinder. The coils are convectively cooled from a cryogenic reservoir in the bore of the coils. The coils are suspended in a cylindrical metal shell which protects the magnet during rail, automotive or shipboard use. It is important to note that the storage unit does not rely on its surroundings for structural support, other than normal gravity and inertial loads. Designs are presented for toroidal energy storage units produced by the systems code. A wide range of several parameters have been considered, resulting in units storing from 1 MJ to 72 GJ. Maximum fields range from 5 T to 20 T. The masses and volumes of the coils, bucking cylinder, coolant, insulation and outer shell are calculated. For unattended use, the allowable operating time using only the boiloff of the cryogenic fluid for refrigeration is calculated. For larger units, the coils were divided into modules suitable for normal truck or rail transport.

  1. Design and Implementation of Fixed Point Arithmetic Unit

    Directory of Open Access Journals (Sweden)

    S Ramanathan

    2016-06-01

    Full Text Available This paper aims at Implementation of Fixed Point Arithmetic Unit. The real number is represented in Qn.m format where n is the number of bits to the left of the binary point and m is the number of bits to the right of the binary point. The Fixed Point Arithmetic Unit was designed using Verilog HDL. The Fixed Point Arithmetic Unit incorporates adder, multiplier and subtractor. We carried out the simulations in ModelSim and Cadence IUS, used Cadence RTL Compiler for synthesis and used Cadence SoC Encounter for physical design and targeted 180 nm Technology for ASIC implementation. From the synthesis result it is found that our design consumes 1.524 mW of power and requires area 20823.26 μm2 .

  2. Energy and Protein Delivery in Overweight and Obese Children in the Pediatric Intensive Care Unit.

    Science.gov (United States)

    Martinez, Enid E; Ariagno, Katelyn A; Stenquist, Nicole; Anderson, Daniela; Muñoz, Eliana; Mehta, Nilesh M

    2017-06-01

    Early and optimal energy and protein delivery have been associated with improved clinical outcomes in the pediatric intensive care unit (PICU). Overweight and obese children in the PICU may be at risk for suboptimal macronutrient delivery; we aimed to describe macronutrient delivery in this cohort. We performed a retrospective study of PICU patients ages 2-21 years, with body mass index (BMI) ≥85th percentile and >48 hours stay. Nutrition variables were extracted regarding nutrition screening and assessment, energy and protein prescription, and delivery. Data from 83 patient encounters for 52 eligible patients (52% male; median age 9.6 [5-15] years) were included. The study cohort had a longer median PICU length of stay (8 vs 5 days, P Energy expenditure was estimated primarily by predictive equations. Stress factor >1.0 was applied in 44% (22/50). Median energy delivered as a percentage of estimated requirements by the Schofield equation was 34.6% on day 3. Median protein delivered as a percentage of recommended intake was 22.1% on day 3. The study cohort had suboptimal nutrition assessments and macronutrient delivery during their PICU course. Mortality and duration of PICU stay were greater when compared with the general PICU population. Nutrition assessment, indirect calorimetry-guided energy prescriptions, and optimizing the delivery of energy and protein must be emphasized in this cohort. The impact of these practices on clinical outcomes must be investigated.

  3. Optimization Approaches for Designing Quantum Reversible Arithmetic Logic Unit

    Science.gov (United States)

    Haghparast, Majid; Bolhassani, Ali

    2016-03-01

    Reversible logic is emerging as a promising alternative for applications in low-power design and quantum computation in recent years due to its ability to reduce power dissipation, which is an important research area in low power VLSI and ULSI designs. Many important contributions have been made in the literatures towards the reversible implementations of arithmetic and logical structures; however, there have not been many efforts directed towards efficient approaches for designing reversible Arithmetic Logic Unit (ALU). In this study, three efficient approaches are presented and their implementations in the design of reversible ALUs are demonstrated. Three new designs of reversible one-digit arithmetic logic unit for quantum arithmetic has been presented in this article. This paper provides explicit construction of reversible ALU effecting basic arithmetic operations with respect to the minimization of cost metrics. The architectures of the designs have been proposed in which each block is realized using elementary quantum logic gates. Then, reversible implementations of the proposed designs are analyzed and evaluated. The results demonstrate that the proposed designs are cost-effective compared with the existing counterparts. All the scales are in the NANO-metric area.

  4. PORFLOW Simulations Supporting Saltstone Disposal Unit Design Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Flach, G. P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hang, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Taylor, G. A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-12-10

    SRNL was requested by SRR to perform PORFLOW simulations to support potential cost-saving design modifications to future Saltstone Disposal Units in Z-Area (SRR-CWDA-2015-00120). The design sensitivity cases are defined in a modeling input specification document SRR-CWDA-2015-00133 Rev. 1. A high-level description of PORFLOW modeling and interpretation of results are provided in SRR-CWDA-2015-00169. The present report focuses on underlying technical issues and details of PORFLOW modeling not addressed by the input specification and results interpretation documents. Design checking of PORFLOW modeling is documented in SRNL-L3200-2015-00146.

  5. DESIGNING FEATURES OF POWER OPTICAL UNITS FOR TECHNOLOGICAL EQUIPMENT

    Directory of Open Access Journals (Sweden)

    M. Y. Afanasiev

    2016-03-01

    Full Text Available This paper considers the question of an optical unit designing for transmitting power laser radiation through an optical fiber. The aim of this work is designing a simple construction unit with minimized reflection losses. The source of radiation in the optical unit described below is an ultraviolet laser with diode pumping. We present the general functioning scheme and designing features for the three main parts: laser beam deflecting system, laser beam dump and optical unit control system. The described laser beam deflection system is composed of a moving flat mirror and a spherical scattering mirror. Comparative analysis of the production technology for such mirrors was carried out, and, as a result, the decision was made to produce both mirrors of 99.99 % pure molybdenum without coating. A moving mirror deflects laser emission from a source through a fiber or deflects it on a spherical mirror and into the laser beam dump, moreover, switching from one position to another occurs almost immediately. It is shown that a scattering mirror is necessary, otherwise, the absorbing surface of the beam dump is being worn out irregularly. The laser beam dump is an open conical cavity, in which the conical element with its spire turned to the emission source is placed. Special microgeometry of the internal surface of the beam dump is suggested for the better absorption effect. An optical unit control system consists of a laser beam deflection system, laser temperature sensor, deflection system solenoid temperature sensor, and deflection mirror position sensor. The signal processing algorithm for signals coming from the sensors to the controller is described. The optical unit will be used in special technological equipment.

  6. SIMULATION IN THERMAL DESIGN FOR ELECTRONIC CONTROL UNIT OF ELECTRONIC UNIT PUMP

    Institute of Scientific and Technical Information of China (English)

    XU Quankui; ZHU Keqing; ZHUO Bin; MAO Xiaojian; WANG Junxi

    2008-01-01

    The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation, the thermal design of ECU for electronic unit pump (EUP) fuel system is applied. The power dissipation model of each power component in the ECU is created and simulated. According to the analyses of simulation results, the factors which affect the power dissipation of components are analyzed. Then the ways for reducing the power dissipation of power components are carried out. The power dissipation of power components at different engine state is calculated and analyzed. The maximal power dissipation of each power component in all possible engine state is also carried out based on these simulations. A cooling system is designed based on these studies. The tests show that the maximum total power dissipation of ECU drops from 43.2 W to 33.84 W after these simulations and optimizations. These applications of simulations in thermal design of ECU can greatly increase the quality of the design, save the design cost and shorten design time

  7. The Important Role of Effective Communication in PICU%有效沟通在PICU中的重要作用

    Institute of Scientific and Technical Information of China (English)

    王金丽; 韩莹

    2015-01-01

    为了探讨有效沟通在PICU中的作用,本研究根据Zung焦虑自量表(SAS)对85名患儿家属利用问卷形式进行调查,并根据结果进行及时、有效的沟通,从而得出结论:通过有效沟通可以减少家属的焦虑情绪,明显提高家属的信任感,提高治愈率,减少纠纷的发生。%In order to explore the ef ective communication in the role of PICU,according to the Zung anxiety self assessment scale (SAS)of 85children with their families were investigated with questionnaire,and timely,ef ective communication according to the results,thus the conclusion is drawn:the PICU family of mental burden and psychological health level was significantly lower than that of ordinary families,through ef ective communication can reduce the anxiety of relatives,significantly improve the family trust,improve the cure rate,reduce the occur ence ofdisputes.

  8. The vacuum system for technological unit development and design

    Science.gov (United States)

    Zhukeshov, A. M.; Gabdullina, A. T.; Amrenova, A. U.; Giniyatova, Sh G.; Kaibar, A.; Sundetov, A.; Fermakhan, K.

    2015-11-01

    The paper shows results of development of plasma technological unit on the basis of accelerator of vacuum arc and automated system. During the previous years, the authors investigated the operation of pulsed plasma accelerator and developed unique technologies for hardening of materials. Principles of plasma formation in pulsed plasma accelerator were put into basis of the developed unit. Operation of the pulsed arc accelerator was investigated at different parameters of the charge. The developed vacuum system is designed for production of hi-tech plasma units in high technologies in fields of nanomaterials, mechanical and power engineering and production with high added value. Unlike integrated solutions, the system is a module one to allow its low cost, high reliability and simple maintenance. The problems of use of robots are discussed to modernize the technological process.

  9. PICU多药耐药菌分布与耐药性分析%Distribution and drug resistance of multidrug-resistant bacteria in PICU

    Institute of Scientific and Technical Information of China (English)

    张海金; 李荣; 程丽萍; 姜亚绒; 沈红莉; 任红月; 黄宏志; 陈晴

    2015-01-01

    OBJECTIVE To investigate the distribution and drug resistance of multidrug‐resistant bacteria isolated from pediatric intensive care unit (PICU ) so as to provide guidance for reasonable clinical use of antibiotics . METHODS A total of 112 strains of multidrug‐resistant bacteria were isolated from the PICU of the children's hos‐pital from Jun 2012 to May 2013 ,then the distribution ,constituent ratios ,and drug resistance of the strains were retrospectively analyzed .RESULTS Totally 112 strains of multidrug‐resistant bacteria have been isolated ,including 85 (75 .9% ) strains of gram‐negative bacteria and 27 (24 .1% ) strains of gram‐positive bacteria ;the Acinetobacter baumannii (48 strains ,42 .9% ) was the predominant species of gram‐negative bacteria ,followed by the Esche‐richia coli (13 .4% ) and K lebsiella pneumoniae (12 .5% ) .The drug resistance rate of the A .baumannii to imi‐penem was 95 .8% ,the drug resistance rate of the E .coli and K .pneumoniae to cefotaxime was 100 .0% ,and the drug resistance rates of the Staphylococcus aureus to penicillin and azithromycin were as high as 100 .0% .The major species of multidrug‐resistant gram‐positive bacteria were susceptible to vancomycin and teicoplanin ,and the main gram‐negative bacteria were susceptible to ciprofloxacin ,cefoperazone‐sulbactam ,and piperacillin‐tazobac‐tam .CONCLUSION The gram‐negative bacteria are dominant among the multidrug‐resistant bacteria causing infec‐tions in the children of PICU .It is necessary for the hospital to adjust the drug therapy according to the results of bacterial culture and drug susceptibility testing and reasonably use antibiotics so as to reduce the drug‐resistant strains and control the prevalence of multidrug‐resistant bacteria infections .%目的:了解儿科重症监护病房(PIC U )多药耐药菌分布及其耐药性,为临床用药提供合理的参考依据。方法对2012年6月-2013年5

  10. The relationship between the location of pediatric intensive care unit facilities and child death from trauma: a county-level ecologic study.

    Science.gov (United States)

    Odetola, Folafoluwa O; Miller, William C; Davis, Matthew M; Bratton, Susan L

    2005-07-01

    To describe the relationship between the location of Pediatric Intensive Care Unit (PICU) facilities and county-level child death from trauma in the contiguous USA. We conducted a cross-sectional ecologic study using county-level data on death due to trauma in children 0 to 14 years of age from 1996 to 1998. These data were linked to 1997 county-level data on availability of PICU facilities. In 1997, PICU facilities were present in 9% of USA counties. There were 18,337 childhood deaths from trauma in the study period. The presence of PICU facilities in a county was associated with lower mortality from trauma (incidence rate ratio [IRR] = 0.72; 95% CI 0.67-0.78) compared to counties without PICU facilities. After controlling for residence in rural and low-income counties, and the presence of adult medicosurgical intensive care units, the presence of PICU facilities in a county remained associated with lower rates of death from trauma (IRR = 0.82; 95% CI 0.75-0.89). The presence of PICU facilities is related to lower mortality rates due to traumatic injuries at the county level. This finding may reflect the concentration of pediatric subspecialty care in counties with PICUs. This association merits further study with individual-level observations.

  11. Electronic Unit Pump Diesel Engine Control Unit Design for Integrated Powertrain System

    Institute of Scientific and Technical Information of China (English)

    LIU Bo-lan; ZHAO Chang-lu; ZHANG Fu-jun; HUANG Ying

    2005-01-01

    The performance of the electronic unit pump (EUP) diesel engine is studied, it will be used in the integrated powertrain and its multi parameters are controllable. Both the theoretical analysis and experiment research are taken. A control unit for the fuel quantity and timing in crankshaft domain is designed on this basis and the engine experiment test has been done. For the constant speed camshaft driving EUP system, the fuel quantity will increase as the supply angle goes up and injection timing has no effect. The control precision can reach 1°CA. The full injection timing MAP and engine peak performance curves are made successfully.

  12. Designing Sustainable Urban Social Housing in the United Arab Emirates

    Directory of Open Access Journals (Sweden)

    Khaled Galal Ahmed

    2017-08-01

    Full Text Available The United Arab Emirates is experiencing a challenging turn towards sustainable social housing. Conventional neighborhood planning and design principles are being replaced by those leading to more sustainable urban forms. To trace this challenging move, the research has investigated the degree of consideration of sustainable urban design principles in two social housing neighborhoods in Al Ain City in Abu Dhabi Emirate, UAE. The first represents a conventional urban form based on the neighborhood theory; the other represents the new sustainable design. The ultimate aim is to define the obstacles hindering the full achievement of a sustainable urban form in this housing type. To undertake research investigations, a matrix of the design principles of sustainable urban forms has been initiated in order to facilitate the assessment of the urban forms of the two selected urban communities. Some qualitatively measurable design elements have been defined for each of these principles. The results of the analysis of the shift from ‘conventional’ to ‘sustainable’ case studies have revealed some aspects that would prevent the attainment of fully sustainable urban forms in newly designed social housing neighborhoods. Finally, the research concludes by recommending some fundamental actions to help meet these challenges in future design.

  13. Formal design specification of a Processor Interface Unit

    Science.gov (United States)

    Fura, David A.; Windley, Phillip J.; Cohen, Gerald C.

    1992-01-01

    This report describes work to formally specify the requirements and design of a processor interface unit (PIU), a single-chip subsystem providing memory-interface bus-interface, and additional support services for a commercial microprocessor within a fault-tolerant computer system. This system, the Fault-Tolerant Embedded Processor (FTEP), is targeted towards applications in avionics and space requiring extremely high levels of mission reliability, extended maintenance-free operation, or both. The need for high-quality design assurance in such applications is an undisputed fact, given the disastrous consequences that even a single design flaw can produce. Thus, the further development and application of formal methods to fault-tolerant systems is of critical importance as these systems see increasing use in modern society.

  14. Design and Simulation of an Absorption Diffusion Solar Refrigeration Unit

    Directory of Open Access Journals (Sweden)

    B. Chaouachi

    2007-01-01

    Full Text Available The purpose of this study was the design and the simulation of an absorption diffusion refrigerator using solar as source of energy, for domestic use. The design holds account about the climatic conditions and the unit cost due to technical constraints imposed by the technology of the various components of the installation such as the solar generator, the condenser, the absorber and the evaporator. Mass and energy conservation equations were developed for each component of the cycle and solved numerically. The obtained results showed, that the new designed mono pressure absorption cycle of ammonia was suitable well for the cold production by means of the solar energy and that with a simple plate collector we can reach a power, of the order of 900 watts sufficient for domestic use.

  15. Efficient Design in a DC to DC Converter Unit

    Science.gov (United States)

    Bruemmer, Joel E.; Williams, Fitch R.; Schmitz, Gregory V.

    2002-01-01

    Space Flight hardware requires high power conversion efficiencies due to limited power availability and weight penalties of cooling systems. The International Space Station (ISS) Electric Power System (EPS) DC-DC Converter Unit (DDCU) power converter is no exception. This paper explores the design methods and tradeoffs that were utilized to accomplish high efficiency in the DDCU. An isolating DC to DC converter was selected for the ISS power system because of requirements for separate primary and secondary grounds and for a well-regulated secondary output voltage derived from a widely varying input voltage. A flyback-current-fed push-pull topology or improved Weinberg circuit was chosen for this converter because of its potential for high efficiency and reliability. To enhance efficiency, a non-dissipative snubber circuit for the very-low-Rds-on Field Effect Transistors (FETs) was utilized, redistributing the energy that could be wasted during the switching cycle of the power FETs. A unique, low-impedance connection system was utilized to improve contact resistance over a bolted connection. For improved consistency in performance and to lower internal wiring inductance and losses a planar bus system is employed. All of these choices contributed to the design of a 6.25 KW regulated dc to dc converter that is 95 percent efficient. The methodology used in the design of this DC to DC Converter Unit may be directly applicable to other systems that require a conservative approach to efficient power conversion and distribution.

  16. 3 CFR - Designation of Officers of the United States Section, International Boundary and Water Commission...

    Science.gov (United States)

    2010-01-01

    ..., International Boundary and Water Commission, United States and Mexico To Act as the Commissioner of the United... Designation of Officers of the United States Section, International Boundary and Water Commission, United... of the United States Section, International Boundary and Water Commission, United......

  17. Architecture and Design of Medical Processor Units for Medical Networks

    Directory of Open Access Journals (Sweden)

    Syed V. Ahamed

    2010-11-01

    Full Text Available This paper1 introduces analogical and deductive methodologies for the design medical processor units(MPUs. From the study of evolution of numerous earlier processors, we derive the basis for thearchitecture of MPUs. These specialized processors perform unique medical functions encoded as medicaloperational codes (mopcs. From a pragmatic perspective, MPUs function very close to CPUs. Bothprocessors have unique operation codes that command the hardware to perform a distinct chain of subprocessesupon operands and generate a specific result unique to the opcode and the operand(s. Inmedical environments, MPU decodes the mopcs and executes a series of medical sub-processes and sendsout secondary commands to the medical machine. Whereas operands in a typical computer system arenumerical and logical entities, the operands in medical machine are objects such as such as patients, bloodsamples, tissues, operating rooms, medical staff, medical bills, patient payments, etc. We follow thefunctional overlap between the two processes and evolve the design of medical computer systems andnetworks.

  18. Design and test hardware for a solar array switching unit

    Science.gov (United States)

    Patil, A. R.; Cho, B. H.; Sable, D.; Lee, F. C.

    1992-01-01

    This paper describes the control of a pulse width modulated (PWM) type sequential shunt switching unit (SSU) for spacecraft applications. It is found that the solar cell output capacitance has a significant impact on SSU design. Shorting of this cell capacitance by the PWM switch causes input current surges. These surges are minimized by the use of a series filter inductor. The system with a filter is analyzed for ripple and the control to output-voltage transfer function. Stable closed loop design considerations are discussed. The results are supported by modeling and measurements of loop gain and of closed-loop bus impedance on test hardware for NASA's 120 V Earth Observation System (EOS). The analysis and modeling are also applicable to NASA's 160 V Space Station power system.

  19. Representing the Learning Design of Units of Learning

    Directory of Open Access Journals (Sweden)

    Bill Olivier

    2004-07-01

    Full Text Available In order to capture current educational practices in eLearning courses, more advanced ‘learning design’ capabilities are needed than are provided by the open eLearning specifications hitherto available. Specifically, these fall short in terms of multi-role workflows, collaborative peer-interaction, personalization and support for learning services. We present a new specification that both extends and integrates current specifications to support the portable representation of units of learning (e.g. lessons, learning events that have advanced learning designs. This is the Learning Design specification. It enables the creation of a complete, abstract and portable description of the pedagogical approach taken in a course, which can then be realized by a conforming system. It can model multi-role teaching-learning processes and supports personalization of learning routes. The underlying generic pedagogical modelling language has been translated into a specification (a standard developed and agreed upon by domain and industry experts that was developed in the context of IMS, one of the major bodies involved in the development of interoperability specifications in the field of eLearning. The IMS Learning Design specification is discussed in this article in the context of its current status, its limitations and its future development.

  20. Antenna Design Considerations for the Advanced Extravehicular Mobility Unit

    Science.gov (United States)

    Bakula, Casey J.; Theofylaktos, Onoufrios

    2015-01-01

    NASA is designing an Advanced Extravehicular Mobility Unit (AEMU)to support future manned missions beyond low-Earth orbit (LEO). A key component of the AEMU is the communications assembly that allows for the wireless transfer of voice, video, and suit telemetry. The Extravehicular Mobility Unit (EMU) currently used on the International Space Station (ISS) contains a radio system with a single omni-directional resonant cavity antenna operating slightly above 400 MHz capable of transmitting and receiving data at a rate of about 125 kbps. Recent wireless communications architectures are calling for the inclusion of commercial wireless standards such as 802.11 that operate in higher frequency bands at much higher data rates. The current AEMU radio design supports a 400 MHz band for low-rate mission-critical data and a high-rate band based on commercial wireless local area network (WLAN) technology to support video, communication with non-extravehicular activity (EVA) assets such as wireless sensors and robotic assistants, and a redundant path for mission-critical EVA data. This paper recommends the replacement of the existing EMU antenna with a new antenna that maintains the performance characteristics of the current antenna but with lower weight and volume footprints. NASA has funded several firms to develop such an antenna over the past few years, and the most promising designs are variations on the basic patch antenna. This antenna technology at UHF is considered by the authors to be mature and ready for infusion into NASA AEMU technology development programs.

  1. Measuring the quality of therapeutic apheresis care in the pediatric intensive care unit.

    Science.gov (United States)

    Sussmane, Jeffrey B; Torbati, Dan; Gitlow, Howard S

    2012-01-01

    Our goal was to measure the quality of care provided in the Pediatric Intensive Care Unit (PICU) during Therapeutic Apheresis (TA). We described the care as a step by step process. We designed a flow chart to carefully document each step of the process. We then defined each step with a unique clinical indictor (CI) that represented the exact task we felt provided quality care. These CIs were studied and modified for 1 year. We measured our performance in this process by the number of times we accomplished the CI vs. the total number of CIs that were to be performed. The degree of compliance, with these clinical indicators, was analyzed and used as a metric for quality by calculating how close the process is running exactly as planned or "in control." The Apheresis Process was in control (compliance) for 47% of the indicators, as measured in the aggregate for the first observational year. We then applied the theory of Total Quality Management (TQM) through our Design, Measure, Analyze, Improve, and Control (DMAIC) model. We were able to improve the process and bring it into control by increasing the compliance to > 99.74%, in the aggregate, for the third and fourth quarter of the second year. We have implemented TQM to increase compliance, thus control, of a highly complex and multidisciplinary Pediatric Intensive Care therapy. We have shown a reproducible and scalable measure of quality for a complex clinical process in the PICU, without additional capital expenditure.

  2. Architecture and Design of Medical Processor Units for Medical Networks

    CERN Document Server

    Ahamed, Syed V; 10.5121/ijcnc.2010.2602

    2011-01-01

    This paper introduces analogical and deductive methodologies for the design medical processor units (MPUs). From the study of evolution of numerous earlier processors, we derive the basis for the architecture of MPUs. These specialized processors perform unique medical functions encoded as medical operational codes (mopcs). From a pragmatic perspective, MPUs function very close to CPUs. Both processors have unique operation codes that command the hardware to perform a distinct chain of subprocesses upon operands and generate a specific result unique to the opcode and the operand(s). In medical environments, MPU decodes the mopcs and executes a series of medical sub-processes and sends out secondary commands to the medical machine. Whereas operands in a typical computer system are numerical and logical entities, the operands in medical machine are objects such as such as patients, blood samples, tissues, operating rooms, medical staff, medical bills, patient payments, etc. We follow the functional overlap betw...

  3. Design of the magnetic diagnostics unit onboard LISA Pathfinder

    CERN Document Server

    Diaz-Aguiló, Marc; Ramos-Castro, Juan; Lobo, Alberto; García-Berro, Enrique

    2012-01-01

    LISA (Laser Interferometer Space Antenna) is a joint mission of ESA and NASA which aims to be the first space-borne gravita- tional wave observatory. Due to the high complexity and technological challenges that LISA will face, ESA decided to launch a technological demonstrator, LISA Pathfinder. The payload of LISA Pathfinder is the so-called LISA Technology Package, and will be the highest sensitivity geodesic explorer flown to date. The LISA Technology Package is designed to measure relative accelerations between two test masses in nominal free fall (geodesic motion). The magnetic, thermal and radiation disturbances affecting the payload are monitored and dealt by the diagnostics subsystem. The diagnostics subsystem consists of several modules, and one of these is the magnetic diagnostics unit. Its main function is the assessment of differential acceleration noise between test masses due to the magnetic effects. To do so, it has to determine the magnetic characteristics of the test masses, namely their magne...

  4. [Visitation policy, design and comfort in Spanish intensive care units].

    Science.gov (United States)

    Escudero, D; Martín, L; Viña, L; Quindós, B; Espina, M J; Forcelledo, L; López-Amor, L; García-Arias, B; del Busto, C; de Cima, S; Fernández-Rey, E

    2015-01-01

    To determine the design and comfort in the Intensive Care Units (ICUs), by analysing visiting hours, information, and family participation in patient care. Descriptive, multicentre study. Spanish ICUs. A questionnaire e-mailed to members of the Spanish Society of Intensive Care Medicine, Critical and Coronary Units (SEMICYUC), subscribers of the Electronic Journal Intensive Care Medicine, and disseminated through the blog Proyecto HU-CI. A total of 135 questionnaires from 131 hospitals were analysed. Visiting hours: 3.8% open 24h, 9.8% open daytime, and 67.7% have 2 visits a day. Information: given only by the doctor in 75.2% of the cases, doctor and nurse together in 4.5%, with a frequency of once a day in 79.7%. During weekends, information is given in 95.5% of the cases. Information given over the phone 74.4%. Family participation in patient care: hygiene 11%, feeding 80.5%, physiotherapy 17%. Personal objects allowed: mobile phone 41%, computer 55%, sound system 77%, and television 30%. Architecture and comfort: all individual cubicles 60.2%, natural light 54.9%, television 7.5%, ambient music 12%, clock in the cubicle 15.8%, environmental noise meter 3.8%, and a waiting room near the ICU 68.4%. Visiting policy is restrictive, with a closed ICU being the predominating culture. On average, technological communication devices are not allowed. Family participation in patient care is low. The ICU design does not guarantee privacy or provide a desirable level of comfort. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.

  5. Remote Maintenance Design Guide for Compact Processing Units

    Energy Technology Data Exchange (ETDEWEB)

    Draper, J.V.

    2000-07-13

    Oak Ridge National Laboratory (ORNL) Robotics and Process Systems (RPSD) personnel have extensive experience working with remotely operated and maintained systems. These systems require expert knowledge in teleoperation, human factors, telerobotics, and other robotic devices so that remote equipment may be manipulated, operated, serviced, surveyed, and moved about in a hazardous environment. The RPSD staff has a wealth of experience in this area, including knowledge in the broad topics of human factors, modular electronics, modular mechanical systems, hardware design, and specialized tooling. Examples of projects that illustrate and highlight RPSD's unique experience in remote systems design and application include the following: (1) design of a remote shear and remote dissolver systems in support of U.S. Department of Energy (DOE) fuel recycling research and nuclear power missions; (2) building remotely operated mobile systems for metrology and characterizing hazardous facilities in support of remote operations within those facilities; (3) construction of modular robotic arms, including the Laboratory Telerobotic Manipulator, which was designed for the National Aeronautics and Space Administration (NASA) and the Advanced ServoManipulator, which was designed for the DOE; (4) design of remotely operated laboratories, including chemical analysis and biochemical processing laboratories; (5) construction of remote systems for environmental clean up and characterization, including underwater, buried waste, underground storage tank (UST) and decontamination and dismantlement (D&D) applications. Remote maintenance has played a significant role in fuel reprocessing because of combined chemical and radiological contamination. Furthermore, remote maintenance is expected to play a strong role in future waste remediation. The compact processing units (CPUs) being designed for use in underground waste storage tank remediation are examples of improvements in systems

  6. Frida integral field unit opto-mechanical design

    Science.gov (United States)

    Cuevas, Salvador; Eikenberry, Stephen S.; Bringas, Vicente; Corrales, Adi; Espejo, Carlos; Lucero, Diana; Rodriguez, Alberto; Sánchez, Beatriz; Uribe, Jorge

    2012-09-01

    FRIDA (inFRared Imager and Dissector for the Adaptive optics system of the Gran Telescopio Canarias) has been designed as a cryogenic and diffraction limited instrument that will offer broad and narrow band imaging and integral field spectroscopy (IFS). Both, the imaging mode and IFS observing modes will use the same Teledyne 2Kx2K detector. This instrument will be installed at Nasmyth B station, behind the GTC Adaptive Optics system. FRIDA will provide the IFS mode using a 30 slices Integral Field Unit (IFU). This IFU design is based on University of Florida FISICA where the mirror block arrays are diamond turned on monolithic metal blocks. FRIDA IFU is conformed mainly by 3 mirror blocks with 30 spherical mirrors each. It also has a Schwarzschild relay based on two off axis spherical mirrors and an afocal system of two parabolic off axis mirrors. Including two insertion mirrors the IFU holds 96 metal mirrors. Each block or individual mirror is attached on its own mechanical mounting. In order to study beam interferences with mechanical parts, ghosts and scattered light, an iterative optical-mechanical modeling was developed. In this work this iterative modeling is described including pictures showing actual ray tracing on the opto-mechanical components.

  7. Custom Unit Pump Design and Testing for the EVA PLSS

    Science.gov (United States)

    Schuller, Michael; Kurwitz, Cable; Goldman, Jeff; Morris, Kim; Trevino, Luis

    2009-01-01

    This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the pre-flight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion , and restart capability under both ambient and vacuum conditions. The pump operated between 40 and 240 lbm/hr flowrate, 35 to 100 F

  8. Nutrition in the pediatric population in the intensive care unit.

    Science.gov (United States)

    Verger, Judy

    2014-06-01

    Nutrition is an essential component of patient management in the pediatric intensive care unit (PICU). Poor nutrition status accompanies many childhood chronic illnesses. A thorough assessment of the critically ill child is required to inform the plan for nutrition support. Accurate and clinically relevant nutritional assessment, including growth measurements, provides important guidance. Indirect calorimetry provides the most accurate measurement of resting energy expenditure, but is too often unavailable in the PICU. To prevent inappropriate caloric intake, reassessment of the child's nutrition status is imperative. Enteral nutrition is the recommended route of intake. Human milk is preferred for infants. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. 77 FR 38857 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Normal...

    Science.gov (United States)

    2012-06-29

    ... COMMISSION Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Normal..., Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems..., entitled, ``Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of...

  10. 儿童重症监护病房鲍氏不动杆菌临床分布及耐药性变化趋势分析%Clinical distribution of acinetobacter baumannii in PICU and trend of antibiotics resistance

    Institute of Scientific and Technical Information of China (English)

    蔡小芳; 孙继民; 鲍连生; 李文斌

    2011-01-01

    OBJECTIVE To investigate the distribution of clinical strains and antibiotic resistance of Acinetobacter baumannii (ABA) in the pediatric intensive care unit (PICU) and to provide evidence for reasonable use of antibiotics. METHODS VITEK-32 automicroscan was used to identify the species. Susceptibility was tested by Kirby-Bauer method. The results were interpreted according to the guideline of Clinical and Laboratory Standards Institute. RESULTS 329 clinical strains of ABA were isolated from 2007 to 2009, [45 in 2007(9.57%), 74 in 2008(12.67 % ) and 210 in 2009 (24.33 % ) ]. The strains of ABA were mainly isolated from sputum and tracheal aspirates (89.36%), and pneumonia was the most common basic disease in PICU (80.24%). The results of drug susceptibility tests indicated that the antibiotic resistance rate of ABA was generally high and increased by years.Amikacin, Levofloxacin and Ciprofloxacin had the lowest drug-resistance (<3%), followed by Cefoperazonesulbactam (17.14%). To the other antibiotics such as Penicillins and Cephalosporins, the rates of drug-resistance were more than 70%. The average rate to Imipenem and Meropenem was higher than 60.0%. CONCLUSIONS The infection of multidrug-resistant ABA has increasing tendency in PICU. It should continue to strengthen the monitoring of the antibiotic resistance and select antibiotics according to the drug sensitivity test. Meanwhile the disinfection should be strengthened for hospital environment in order to control the existence and spread of ABA in PICU.%目的 调查儿童重症监护病房(PICU)鲍氏不动杆菌(ABA)临床分布特点及耐药情况,为合理选用抗菌药物提供依据.方法 采用VITEK-32微生物全自动鉴定系统鉴定细菌,以纸片扩散法进行药敏试验,按CLSI标准操作.结果 2007-2009年共检出329株,其中2007年45株、2008年74株、2009年210株,分别占当年总检出率的9.57%、12.67%和24.33%;大部分菌株来源于痰液

  11. 12 CFR 741.204 - Maximum public unit and nonmember accounts, and low-income designation.

    Science.gov (United States)

    2010-01-01

    ... low-income designation. 741.204 Section 741.204 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION... Unions § 741.204 Maximum public unit and nonmember accounts, and low-income designation. Any credit union...) Obtain a low-income designation in order to accept nonmember accounts, other than from public units...

  12. 76 FR 82323 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units

    Science.gov (United States)

    2011-12-30

    ... COMMISSION Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units AGENCY: Nuclear...-1274, ``Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of....'' This guide applies to the design, inspection, and testing of air filtration and iodine adsorption...

  13. A new type of dehydration unit of natural gas and its design considerations

    Institute of Scientific and Technical Information of China (English)

    LIU Hengwei; LIU Zhongliang; ZHANG Jian; GU Keyu; YAN Tingmin

    2005-01-01

    A new type of dehydration unit for natural gas is described and its basic structure and working principles are presented.The key factors affecting the performance and dehydration efficiency of the unit such as nucleation rate, droplet growth rate, the strength of the swirl, and the position at which the shock wave occurs are discussed. And accordingly the design considerations of each component of the unit are provided. Experimental investigations on the working performance of the unit justified the design considerations.

  14. ELT Materials Design of a Speaking Unit based on Needs Analysis

    Institute of Scientific and Technical Information of China (English)

    LIU Ai-juan; TONG Xing-hong; DU Wen-jing

    2016-01-01

    In this article, the authors design a speaking unit based on needs analysis following Hutchinson and Waters’(1987) model. First, the rationale in designing this unit is introduced, which involves the teaching approach adopted and relevant theo-ries in organizing the materials. Then, the teaching plan of this speaking unit is provided and some activities are designed to cre-ate an authentic and optimal situation for students to practice their speaking skill.

  15. Comparison of staff and family perceptions of causes of noise pollution in the Pediatric Intensive Care Unit and suggested intervention strategies

    Directory of Open Access Journals (Sweden)

    Harsheen Kaur

    2016-01-01

    Full Text Available Noise and excessive, unwanted sound in the Pediatric Intensive Care Unit (PICU is common and has a major impact on patients′ sleep and recovery. Previous research has focused mostly on absolute noise levels or included only staff as respondents to acknowledge the causes of noise and to plan for its reduction. Thus far, the suggested interventions have not ameliorated noise, and it continues to serve as a barrier to recovery. In addition to surveying PICU providers through internet-based software, patients′ families were evaluated through in-person interviews utilizing a pretested instrument over 3 months. Families of patients admitted for more than 24 h were considered eligible for evaluation. Participants were asked to rank causes of noise from 1 to 8, with eight being highest, and identified potential interventions as effective or ineffective. In total, 50 families from 251 admissions and 65 staff completed the survey. Medical alarms were rated highest (mean ± standard deviation [SD], 4.9 ± 2.1 [2.8-7.0], followed by noise from medical equipment (mean ± SD, 4.7 ± 2.1 [2.5-6.8]. This response was consistent among PICU providers and families. Suggested interventions to reduce noise included keeping a patient′s room door closed, considered effective by 93% of respondents (98% of staff; 88% of families, and designated quiet times, considered effective by 82% (80% of staff; 84% of families. Keeping the patient′s door closed was the most effective strategy among survey respondents. Most families and staff considered medical alarms an important contributor to noise level. Because decreasing the volume of alarms such that it cannot be heard is inappropriate, alternative strategies to alert staff of changes in vital signs should be explored.

  16. Ergonomic implementation and work station design for quilt manufacturing unit

    Directory of Open Access Journals (Sweden)

    Deepa Vinay

    2012-01-01

    Full Text Available Background: Awkward, extreme and repetitive postures have been associated with work related musculoskeletal disorders and injury to the lowerback of workers engaged in quilting manufacturing unit. Basically quilt are made manually by hand stitch and embroidery on the quilts which was done in squatting posture on the floor. Mending, stain removal, washing and packaging were some other associated work performed on wooden table. their work demands to maintain a continuous squatting posture which leads to various injuries related to low back and to calf muscles. Material and Method s: The present study was undertaken in Tarai Agroclimatic Zone of Udham Singh Nagar District of Uttarakhand State with the objective to study the physical and physiological parameters as well as the work station layout of the respondent engaged on quilt manufacturing unit. A total of 30 subjects were selected to study the drudgery involved in quilt making enterprise and to make the provision of technology option to reduce the drudgery as well as musculoskeletal disorders, thus enhancing the productivity and comfortability. Results: Findings of the investigation show that majority of workers (93.33 per cent were female and very few (6.66 per cent were the male with the mean age of 24.53±6.43. The body mass index and aerobic capacity (lit/min values were found as 21.40±4.13 and 26.02±6.44 respectively. Forty per cent of the respondents were having the physical fitness index of high average whereas 33.33 per cent of the respondents had low average physical fitness. All the assessed activities involved to make the quilt included a number of the steps which were executed using two types of work station i.e squatting posture on floor and standing posture using wooden table. A comparative study of physiological parameters was also done in the existing conditions as well as in improved conditions by introducing low height chair and wooden spreader to hold the load of quilt

  17. A Design Method for Impact-Loaded Slender Armour Units

    DEFF Research Database (Denmark)

    Burcharth, Hans F.

    It is well known that the bigger a structural member like a beam, the relatively weaker it is. In the end it cannot even support its own weight. The same problem holds for slender armour units such as Dolosse....

  18. Design of the optical fiber unit for industrial equipment

    Science.gov (United States)

    Fedosov, Yuri V.; Romanova, Galina E.; Afanasev, Maxim Ya.

    2017-05-01

    Optical systems with UV lasers are widely used in various areas of manufacturing, for processing materials. To provide high operation accuracy, the equipment with high power UV laser sources requires complicated optical and mechanical unit with control electronic blocks. In order to develop successful and stable equipment and to increase accuracy, the development of each part (optical, mechanical, and electronic) is needed to solve many complex engineering problems. In this article the special features of the development of an optical unit with a high powered UV laser source are considered along with some problems and solutions.

  19. Design of reciprocal unit based on the Newton-Raphson approximation

    DEFF Research Database (Denmark)

    Gundersen, Anders Torp; Winther-Almstrup, Rasmus; Boesen, Michael

    A design of a reciprocal unit based on Newton-Raphson approximation is described and implemented. We present two different designs for single precisions where one of them is extremely fast but the trade-off is an increase in area. The solution behind the fast design is that the design is fully...

  20. Design and test of a flywheel energy storage unit for spacecraft application

    Science.gov (United States)

    Cormack, A., III; Notti, J. E., Jr.; Ruiz, M. L.

    1975-01-01

    This paper summarizes the design and test of a development flywheel energy storage device intended for spacecraft application. The flywheel unit is the prototype for the rotating assembly portion of an Integrated Power and Attitude Control System (IPACS). The paper includes a general description of the flywheel unit; specific design characteristics for the rotor and bearings, motor-generators, and electronics; an efficiency analysis; and test results for a research unit.

  1. History of forest survey sampling designs in the United States

    Science.gov (United States)

    W. E. Frayer; George M. Furnival

    2000-01-01

    Extensive forest inventories of forested lands in the United States were begun in the early part of the 20th century, but widespread, frequent use was not common until after WWII. Throughout the development of inventory techniques and their application to assess the status of the nation's forests, most of the work has been done by the USDA Forest Service through...

  2. Costs borne by families of children hospitalized in a pediatric intensive care unit: a pilot study.

    Science.gov (United States)

    Wasserfallen, Jean-Blaise; Bossuat, Christine; Perrin, Eliane; Cotting, Jacques

    2006-12-23

    Hospitalisation of a child in a paediatric intensive care unit (PICU) involves major stress for parents. They wish to stay at their child's bedside while at the same time giving the usual attention to their other children. The resultant out-of-pocket expenses have rarely been studied. Over a 6-month period all the families of children hospitalised in our PICU for more than 4 days, speaking French and insured by our social security system, were eligible for inclusion. Participation was proposed only after diagnosis, treatment and prognosis had been determined. Costs were retrieved from a diary list of customised items and computed as the amount in excess of usual expenses until the end of the hospital stay. 117 children were hospitalised in our PICU for a total of 131 stays. The families of 16 fulfilled the inclusion criteria. One dropped out after a week at the parents' request. The children's age was 2.9 +/- 3.8 years and 67% were male. The majority had malformations (53%) or infections (33%). The total length of stay was 49 +/- 51 days, of which 24 +/- 41 were spent in the PICU. On average, parents spent CHF 86 +/- 31 every day, mainly on travel and meals. Over the entire hospital stay their expenses amounted to CHF 4,078 +/- 4,552. Direct out-of-pocket expenses for parents of children hospitalised in the PICU are considerable. Improvement in the social security system may be necessary to address this issue.

  3. Is there a role for clowns in paediatric intensive care units?

    Science.gov (United States)

    Mortamet, Guillaume; Roumeliotis, Nadia; Vinit, Florence; Simonds, Caroline; Dupic, Laurent; Hubert, Philippe

    2017-02-08

    Hospital clowning is a programme in healthcare facilities involving visits from specially trained actors. In the paediatric intensive care unit (PICU), clowning may appear inappropriate and less intuitive. The patient could appear too ill and/or sedated, the environment too crowded or chaotic and the parents too stressed. Relying on our experience with professionally trained clowns both in France and Canada, the purpose of this article is to offer a model for hospital clowning and to suggest standards of practice for the implementation of clowning in PICUs. In this work, we provide a framework for the implementation of clown care in the PICU, to overcome the challenges related to the complex technical environment, the patient's critical illness and the high parental stress levels. Regardless of the specifics of the PICU, our experience suggests that professional clown activity is feasible, safe and can offer multiple benefits to the child, his/her parents and to hospital personnel. Due to the specific challenges in the PICU, clowns must be educated and prepared to work in this highly specialised environment. We stress that prior to clowning in a PICU, professional performers must be highly trained, experienced, abide by a code of ethics and be fully accepted by the treating healthcare team.

  4. Optimum Structural Design of a Chain-Driving Pumping Unit

    Institute of Scientific and Technical Information of China (English)

    Zhang Ailin; Liu Yang

    1994-01-01

    @@ Operating Principle and Essential Parameters In this paper the pumping unit of type QLCJ14-6 is studied. Through the belt driving unit, the motor drives the driving sprocket in which the rotation rate has been reduced by the reduction gearbox.The locus chain moves between the driving sprocket and upper sprocket which are vertically set. There's a special chain element in the locus chain, which drives the reciprocating holster with the main shaft linchpin and slide block. The reciprocating holster could only move up and down when the locus chain moves in a circle. In this way the up and down stroke of the sucker rod and the machine is realized.The lower end of the reciprocating holster is connected with the equilibrium system to make the structure balance. The balancing cylinder is replaced by the balancing block to make the structure simplified.

  5. Systematic parametric design/calculation of the piston rod unit

    Science.gov (United States)

    Kacani, V.

    2015-08-01

    In this article a modern and economic method for the strength calculation of the piston rod unit and its components under different operating conditions will be presented. Herefore the commercial FEA - Software will be linked with the company-owned calculation tools. The parametric user input will be followed by an automatic Pre- and Postprocessing. Afterwards the strength calculation is processed on all critical points of the piston rod connection, assisted by an extra module, based on general standards and special codes for reciprocating compressors. In this process most arrangements of the piston rod unit as well as the special geometries of the single-components (piston, piston rod and piston nut) can be considered easily. In this article the modeling of the notches, especially on the piston rod, piston as well as the piston nut will be covered in detail.

  6. Representing the Learning Design of Units of Learning

    National Research Council Canada - National Science Library

    Rob Koper; Bill Olivier

    2004-01-01

      In order to capture current educational practices in eLearning courses, more advanced 'learning design' capabilities are needed than are provided by the open eLearning specifications hitherto available...

  7. 脓毒症/严重脓毒症患儿维生素D水平与预后%Relationship of vitamin D in children with sepsis/severe sepsis and outcomes in PICU

    Institute of Scientific and Technical Information of China (English)

    尹冰如; 钱素云; 成怡冰; 陆国平; 祝益民

    2016-01-01

    Objective To determine the vitamin D status in children with sepsis/severe sepsis in pediatric intensive care unit (PICU) in order to explor the association between vitamin D status and clinical outcomes,in turn to provide evidence for optimizing nutrition support.Methods It was a prospective,observational,multi-center study,carried out in patients with sepsis/severe sepsis from March 1,2013,to March 30,2014,in the PICUs of three tertiary-care children's hospitals.Total serum 25-hydroxy vitamin D [25 (OH) D] was measured by using an enzyme-linked immunosorbent assay at admission.The association of vitamin D status at admission with length of PICU length of stay,total hospital stay,in-hospital mortality,28-days mortality and costs were analyzed.Results A total of 194 patients includng 117 boys (60.3%)and 77 girls (39.7%) were enrolled.There were 96 patients with sepsis and 98 with severe sepsis.The mortality on discharge and 28 days were 6.7% and 24.2% respectively.The median vitamin D level was 9.79 ng/mL (5.32,18.46) at admission.Of them 77.8% (151/194) had vitamin D deficiency and 50.5% (98/194) had severe vitamin D deficiency.Patients with severe vitamin D deficiency,had higher mortality on discharge (P =0.011).Vitamin D status had no significant correlations with 28 days mortality,length of PICU stay,total hospital stay and costs.Conclusions More than three-quarters (77.8%) of children with sepsis/severe sepsis in PICUs had Vitamin D deficiency.Patients with severe vitamin D deficiency at admission had higher risk of mortality at discharge.%目的 了解儿童重症监护病房(pediatric intensive care unit,PICU)脓毒症/严重脓毒症患儿维生素D缺乏程度;分析患者入院时维生素D水平与预后之间的关系.方法 本研究为多中心、前瞻性、观察性研究.以2013年3月1日至2014年3月30日期间入住3家儿童医院PICU符合危重症标准的脓毒症/严重脓毒症患儿作为研究对象.入组患者入院24h

  8. Dynamics and design of a power unit with a hydraulic piston actuator

    Science.gov (United States)

    Misyurin, S. Yu.; Kreinin, G. V.

    2016-07-01

    The problem of the preselection of parameters of a power unit of a mechatronic complex on the basis of the condition for providing a required control energy has been discussed. The design of the unit is based on analysis of its dynamics under the effect of a special-type test conditional control signal. The specific features of the approach used are a reasonably simplified normalized dynamic model of the unit and the formation of basic similarity criteria. Methods of designing a power unit with a hydraulic piston actuator that operates in point-to-point and oscillatory modes have been considered.

  9. Design of Piston Air Compressor Unit Control System based Converter

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>Based on the running characteristics and high energy consumption of air compressors in coal mines,an air pressure PID closed loop control system has been designed in this paper.The system is composed of PLC, converter and sensors etc and adopts the control method of converter triple-evaporator which makes air supply"need-based".The designed system has been applied in multiple coal mines and the results show its energy saving is remarkable and potential application is widely.

  10. Design of 8.0Mt/a Atmospheric and Vacuum Distillation Unit

    Institute of Scientific and Technical Information of China (English)

    Li Hejie

    2003-01-01

    The design features of 8 Mt/a atmospheric and vacuum distillation unit (Ⅲ) in Zhenhai Refiningand Chemical Company are presented and various process schemes are compared. Production practice hasproved that the main process design is advanced and reasonable and the process parameters basicallyreached design requirements.

  11. Analysis of the implementation of ergonomic design at the new units of an oil refinery.

    Science.gov (United States)

    Passero, Carolina Reich Marcon; Ogasawara, Erika Lye; Baú, Lucy Mara Silva; Buso, Sandro Artur; Bianchi, Marcos Cesar

    2012-01-01

    Ergonomic design is the adaptation of working conditions to human limitations and skills in the physical design phase of a new installation, a new working system, or new products or tools. Based on this concept, the purpose of this work was to analyze the implementation of ergonomic design at the new industrial units of an oil refinery, using the method of Ergonomic Workplace Assessment. This study was conducted by a multidisciplinary team composed of operation, maintenance and industrial safety technicians, ergonomists, designers and engineers. The analysis involved 6 production units, 1 industrial wastewater treatment unit, and 3 utilities units, all in the design detailing phase, for which 455 ergonomic requirements were identified. An analysis and characterization of the requirements identified for 5 of the production units, involving a total of 246 items, indicated that 62% were related to difficult access and blockage operations, while 15% were related to difficulties in the circulation of employees inside the units. Based on these data, it was found that the ergonomic requirements identified in the design detailing phase of an industrial unit involve physical ergonomics, and that it is very difficult to identify requirements related to organizational or cognitive ergonomics.

  12. Design & Implementation of Company Database for MME Subcontracting Unit

    CERN Document Server

    Horvath, Benedek

    2016-01-01

    The purpose of this document is to introduce the software stack designed and implemented by me, during my student project. The report includes both the project description, the requirements set against the solution, the already existing alternatives for solving the problem, and the final solution that has been implemented. Reading this document you may have a better understanding of what I was working on for eleven weeks in the summer of 2016.

  13. Electric Traction Machine Design for an E-RWD Unit

    OpenAIRE

    Marquez, Francisco

    2014-01-01

    Since the first generation of the Toyota Prius was introduced in December 1997, the number of Hybrid Electric Vehicles (HEVs) and pure Electric Vehicles (EVs) available in the market has increased substantially. The growing competition existent puts high demands on the electric system as well as the rest of the vehicle. As a consequence, substantial design effort is devoted to optimize both at system and component level, with respect to different parameters such as fuel efficiency, power dens...

  14. Design, construction, operation and evaluation of a prototype culm combustion boiler/heater unit. Final design of prototype unit

    Energy Technology Data Exchange (ETDEWEB)

    1980-10-01

    A final design of a prototype anthracite culm combustion boiler has been accomplished under Phase I of DOE Contract ET-78-C-01-3269. The prototype boiler has been designed to generate 20,000 pounds per hour of 150 psig saturated steam using low Btu (4000 Btu per pound) anthracite culm as a fuel. This boiler will be located at the industrial park of the Shamokin Area Industrial Corporation (SAIC). This program is directed at demonstrating the commercial viability of anthracite culm fueled FBC steam generation systems.

  15. Effect Analysis of PDCA Circulation in the PICU Basic Nursing Manage-ment%浅析PDCA循环在PICU基础护理管理中的效果

    Institute of Scientific and Technical Information of China (English)

    马洁

    2016-01-01

    Objective To research and study the application effect of PDCA circulation in the PICU basic nursing manage-ment. Methods PDCA circulation model has been implemented in the basic nursing management in the pediatric intensive care unit of our hospital since January 2014, the patients admitted and treated in the pediatric intensive care unit of our hospital from January 2014 to December 2014 were selected as the observation group, and the patients admitted and treated in the pediatric intensive care unit of our hospital without PDCA circulation model from January 2013 to December 2013 were selected as the control group, and the incidence rates of nursing error events, nursing management quality score and satisfactory degree of nursing services of the two phases were compared. Results The incidence rates of nursing error events in the observation group was obviously decreased after the implementation of PDCA circulation model compared with that in the observation group (P<0.05), but the nursing management quality score and satisfactory degree of nursing services in the observation group were obviously increased(P<0.05). Conclusion The implementation of PDCA circulation model in the ba-sic nursing management of pediatric intensive care unit can effectively improve the nursing management quality, reduce the nursing error event and improve the satisfactory degree of nursing services. With the constant progress of living standards and medical technology, people’s requirement for medical services is stricter and stricter, and the hospital nursing manage-ment has also been widely concerned, especially with the constant occurrence of nurse-patient disputes and nursing safety event in recent years, nursing service quality draws attention to the nursing workers, enhancing nursing management has al-ready been a pressing issue today. It is necessary to enhance the nursing management of the pediatric intensive care unit because the patient’s condition in the pediatric

  16. Bacterial nosocomial pneumonia in Paediatric Intensive Care Unit.

    Directory of Open Access Journals (Sweden)

    Tullu M

    2000-01-01

    Full Text Available AIMS: To determine the incidence, risk factors, mortality and organisms causing nosocomial pneumonia (NP in intubated patients in Paediatric Intensive Care Unit (PICU. MATERIALS & METHODS: All patients with endotracheal (ET tube with or without mechanical ventilation (MV in a PICU of a tertiary care teaching hospital were included in this prospective study. Clinical parameters and investigations were evaluated in patients who developed nosocomial pneumonia (NP. Colonisation of the ET tube tip was studied by culture and the antibiotic susceptibility pattern of the isolates was determined. RESULTS: Sixty-nine patients had an ET tube inserted and fifty-nine of these underwent MV. ET tube tip colonisation was seen in 70 out of 88 ET tubes inserted. The incidence of NP in patients with ET tube was 27.54% (7.96/100 days of ET intubation. NP developed only in patients undergoing MV. The main risk factors for developing NP were - duration of MV and duration of stay in the PICU. Age, sex, immunocompromised status and altered sensorium did not increase the risk of NP. The mortality in cases with NP was 47. 37%. E. coli and Klebsiella were the commonest organisms isolated from the ET tube tip cultures with maximum susceptibility to amikacin and cefotaxime. CONCLUSIONS: NP developed only in patients undergoing MV. Duration of MV and duration of stay in the PICU increased the risk of developing NP.

  17. A Database Design for a Unit Status Reporting System.

    Science.gov (United States)

    1987-03-01

    unlimited. OTIC ELECTE SEP 23 198 ’ 9 *57_3 A 87 9 15 07 DISCLAIMER NOTICE THIS DOCUMENT IS BEST QUALITY PRACTICABLE . THE COPY FURNISHED TO DTIC CONTAINED A...that ame avosable. (6) Dervelop ad - gadame 0 the - - (9) Comander. U S. Army Tritisisg (J) Comsar at all levels wsl review OF IS stan* 4Mt darnin...Meilir. The Practical Guide to Structured -Systems Design. New York: Yourdon Press, 1980. Sprague, Ralph H. Jr., and Carlson, Eric D. Building Effective

  18. New Design of Blade Untwisting Device of Cyclone Unit

    Directory of Open Access Journals (Sweden)

    D. I. Misiulia

    2010-01-01

    Full Text Available The paper presents a new design of a blade untwisting device where blades are considered as a main element of the device. A profile of the blades corresponds to a circular arch. An inlet angle of  the blades is determined by stream aerodynamics in an exhaust pipe, and an exit angle is determined by rectilinear gas motion. Optimum geometrical parameters of the untwisting device have been determined and its application allows to reduce a pressure drop in the ЦН-15 cyclones by 28–30 % while screw-blade untwisting device recovers only 19–20 % of energy.

  19. Design of the Secondary Optical Elements for Concentrated Photovoltaic Units with Fresnel Lenses

    Directory of Open Access Journals (Sweden)

    Yi-Cheng Chen

    2015-10-01

    Full Text Available The goal of this presented study was to determine the optimum parameters of secondary optical elements (SOEs for concentrated photovoltaic (CPV units with flat Fresnel lenses. Three types of SOEs are under consideration in the design process, including kaleidoscope with equal optical path design (KOD, kaleidoscope with flat top surface (KFTS, and open-truncated tetrahedral pyramid with specular walls (SP. The function of using a SOE with a Fresnel lens in a CPV unit is to achieve high optical efficiency, low sensitivity to the sun tracking error, and improved uniformity of irradiance distribution on the solar cell. Ray tracing technique was developed to simulate the optical characteristics of the CPV unit with various design parameters of each type of SOE. Finally, an optimum KOD-type SOE was determined by parametric design process. The resulting optical performance of the CPV unit with the optimum SOE was evaluated in both single-wavelength and broadband simulation of solar spectrum.

  20. Developing advanced units of learning using IMS Learning Design level B

    NARCIS (Netherlands)

    Koper, Rob; Burgos, Daniel

    2005-01-01

    Please cite the original publication: Koper, R., Burgos, D. (2005). Developing advanced units of learning using IMS Learning Design level B. International Journal on Advanced Technology for Learning, 2 (4), 252-259.

  1. Caravaggio: A Design for an Interdisciplinary Content-Based EAP/ESP Unit.

    Science.gov (United States)

    Kirschner, Michal; Wexler, Carol

    2002-01-01

    Presents a detailed design for a content-based unit, the focus of which is the film "Caravaggio." The unit also includes readings in art history and film and is part of a specialized English for academic purposes/English for special purposes reading comprehension course for first-year students majoring in art history and in a…

  2. Perceptions of parents on satisfaction with care in the pediatric intensive care unit : the EMPATHIC study

    NARCIS (Netherlands)

    Latour, Jos M.; van Goudoever, Johannes B.; Duivenvoorden, Hugo J.; van Dam, Nicolette A. M.; Dullaart, Eugenie; Albers, Marcel J. I. J.; Verlaat, Carin W. M.; van Vught, Elise M.; van Heerde, Marc; Hazelzet, Jan A.

    2009-01-01

    To identify parental perceptions on pediatric intensive care-related satisfaction items within the framework of developing a Dutch pediatric intensive care unit (PICU) satisfaction instrument. Prospective cohort study in tertiary PICUs at seven university medical centers in The Netherlands. Parents

  3. Perceptions of parents on satisfaction with care in the pediatric intensive care unit: the EMPATHIC study

    NARCIS (Netherlands)

    J.M. Latour (Jos); J.B. van Goudoever (Hans); H.J. Duivenvoorden (Hugo); N.A.M. van Dam (Nicolette); E. Dullaart (Eugenie); M.J.I.J. Albers (Marcel); C.W.M. Verlaat (Carin); E.M. van Vught (Elise); M. van Heerde (Marc); J.A. Hazelzet (Jan)

    2009-01-01

    textabstractAbstract: PURPOSE: To identify parental perceptions on pediatric intensive care-related satisfaction items within the framework of developing a Dutch pediatric intensive care unit (PICU) satisfaction instrument. METHODS: Prospective cohort study in tertiary PICUs at seven university med

  4. Skin lesions in children admitted to the paediatric intensive care unit: an observational study

    NARCIS (Netherlands)

    Sillevis Smitt, J.H.; van Woensel, J.B.M.; Bos, A.P.

    2011-01-01

    We analysed, by a prospective observational study over a 3-year period, the frequency and character of dermatological symptoms and diseases in children admitted to a tertiary general paediatric intensive care unit (PICU) of a university hospital. Skin problems were observed in 42 of 1,800 children

  5. Impact of malnutrition on pediatric risk of mortality score and outcome in Pediatric Intensive Care Unit

    OpenAIRE

    2016-01-01

    Objectives: This study was done to determine the effect of malnutrition on mortality in Pediatric Intensive Care Unit (PICU) and on the pediatric risk of mortality (PRISM) scoring. Subjects and Methods: This was a prospective study done over 1 year. There were total 400 patients (1 month 14 years), who were divided into cases with weight for age

  6. Design of Parity Preserving Logic Based Fault Tolerant Reversible Arithmetic Logic Unit

    Directory of Open Access Journals (Sweden)

    Rakshith Saligram1

    2013-06-01

    Full Text Available Reversible Logic is gaining significant consideration as the potential logic design style for implementation in modern nanotechnology and quantum computing with minimal impact on physical entropy .Fault Tolerant reversible logic is one class of reversible logic that maintain the parity of the input and the outputs. Significant contributions have been made in the literature towards the design of fault tolerant reversible logic gate structures and arithmetic units, however, there are not many efforts directed towards the design of fault tolerant reversible ALUs. Arithmetic Logic Unit (ALU is the prime performing unit in any computing device and it has to be made fault tolerant. In this paper we aim to design one such fault tolerant reversible ALU that is constructed using parity preserving reversible logic gates. The designed ALU can generate up to seven Arithmetic operations and four logical operations

  7. Design of Parity Preserving Logic Based Fault Tolerant Reversible Arithmetic Logic Unit

    Directory of Open Access Journals (Sweden)

    Rakshith Saligram

    2013-07-01

    Full Text Available Reversible Logic is gaining significant consideration as the potential logic design style for implementationin modern nanotechnology and quantum computing with minimal impact on physical entropy .FaultTolerant reversible logic is one class of reversible logic that maintain the parity of the input and theoutputs. Significant contributions have been made in the literature towards the design of fault tolerantreversible logic gate structures and arithmetic units, however, there are not many efforts directed towardsthe design of fault tolerant reversible ALUs. Arithmetic Logic Unit (ALU is the prime performing unit inany computing device and it has to be made fault tolerant. In this paper we aim to design one such faulttolerant reversible ALU that is constructed using parity preserving reversible logic gates. The designedALU can generate up to seven Arithmetic operations and four logical operations.

  8. Design Analysis of Conveyor Mechanism Unit for Automatic Car Park System

    Directory of Open Access Journals (Sweden)

    Preeti S. Dambhare,

    2015-09-01

    Full Text Available The design analysis of a conveyor mechanism for an automatic car park is discussed. The conveyor assembly is made up of three units; the rack-pinion unit, the cable drive unit and the cantilever. The rack-pinion unit converts the rotational motion of a stepper motor to a linear forward and backward motion of the conveyor. The cable drive converts the rotational motion of another stepper motor to upward and downward motion of the cantilever to lift and lower the car at will. The cantilever is responsible for positioning the vehicle in the stack unit. The parameter for the cantilever is estimated to avoid excess deflection that could result from impact loading of a vehicle on the lift mechanism. The pinion-rack design for strength and rigidity is considered for the load required to be translated by the conveyor. The prototype was interfaced with a computer for operation using parallel port.

  9. Design of the Acoustic Signal Receiving Unit of Acoustic Telemetry While Drilling

    Directory of Open Access Journals (Sweden)

    Li Zhigang

    2016-01-01

    Full Text Available Signal receiving unit is one of the core units of the acoustic telemetry system. A new type of acoustic signal receiving unit is designed to solve problems of the existing devices. The unit is a short joint in whole. It not only can receive all the acoustic signals transmitted along the drill string, without losing any signal, but will not bring additional vibration and interference. In addition, the structure of the amplitude transformer is designed, which can amplify the signal amplitude and improve the receiving efficiency. The design of the wireless communication module makes the whole device can be used in normal drilling process when the drill string is rotating. So, it does not interfere with the normal drilling operation.

  10. Predictors of stress among parents in pediatric intensive care unit: a prospective observational study.

    Science.gov (United States)

    Aamir, Mohd; Mittal, Kundan; Kaushik, Jaya Shankar; Kashyap, Haripal; Kaur, Gurpreet

    2014-11-01

    To determine the sociodemographic and clinical factors leading to stress among parents whose children are admitted in pediatric intensive care unit (PICU). A prospective observational study was conducted in PICU of a tertiary care hospital of north India. Parents of children admitted to PICU for at least 48 h duration were eligible for participation. At the end of 48 h, parental stress was assessed using parental stress scale (PSS:PICU) questionnaire which was administered to the parents. Baseline demographic and clinical parameters of children admitted to PICU were recorded. The parental stress was compared with demographic and clinical characteristics of children using appropriate statistical methods. A total of 49 parents were finally eligible for participation. Mean (SD) parental stress scores was highest in domains of procedures [1.52 (0.66)] and behavior and emotional [1.32 (0.42)] subscales. Mean (SD) total parental stress score among intubated children [1.31 (0.25)] was significantly more than among non intubated children [0.97 (0.26)] (p parental stress score were comparable in terms of gender (p = 0.15) and socioeconomic status (p = 0.32). On subscale analysis, it was found that professional communication is a significant stressor in age groups 0-12 mo [0.61(0.41)] (p = 0.02). It was observed that parents of intubated children were significantly stressed by the physical appearance of their children (p parental role (p = 0.002). Total parental stress score had a positive correlation with PRISM score (r = 0.308). Indian parents are stressed maximally with environment of PICU. Factor leading to parental stress was intubation status of the child and was not affected by gender or socio demographic profile of the parents.

  11. Designing in an Interplay with a Product Model - Explained by Design Units

    DEFF Research Database (Denmark)

    Mortensen, Niels Henrik; Andreasen, Mogens Myrup

    1996-01-01

    If we expand the concept of product models from a bill of material and representations of parts to a genetic model (a chromosome), which is able to capture decisions on functions and design concepts during the design activity, a new design situation is created. This paper treats designing...... in an interplay with a product model in a so-called Designer's Workbench, based on the clarification of the structuring of the product model, the design operationswhich succesively build up the product model, and the role of the product model in the design work as basis for synthesis and modelling of properties....... The main results from this paper are identification of the classes of product models in a Designer's Workbench and description of a scenario for designing in an interplay with the product models....

  12. Validation of Fuqing Nuclear Power Plant Unit 1 Cycle 2 Refueling Design

    Institute of Scientific and Technical Information of China (English)

    PAN; Cui-jie; XIA; Zhao-dong; ZHU; Qing-fu

    2015-01-01

    Fuqing Nuclear Power Plant Unit 1Cycle 2refueling design was validated with the PWR core fuel management package CMS(CASMO5,CMSLINK5and SIMULATE5),including validating fuel management report,validating reload safety evaluation report,validating nuclear design report and validating physics tests report.

  13. The HIGHLEAD program: locating and designing highlead harvest units by using digital terrain models.

    Science.gov (United States)

    R.H. Twito; S.E. Reutebuch; R.J. McGaughey

    1988-01-01

    PLANS, a software package for integrated timber-harvest planning, uses digital terrain models to provide the topographic data needed to fit harvest and transportation designs to specific terrain. HIGHLEAD, an integral program in the PLANS package, is used to design the timber-harvest units to be yarded by highlead systems. It solves for the yarding limits of direct...

  14. The SKYTOWER and SKYMOBILE programs for locating and designing skyline harvest units.

    Science.gov (United States)

    R.H. Twito; R.J. McGaughey; S.E. Reutebuch

    1988-01-01

    PLANS, a software package for integrated timber-harvest planning, uses digital terrain models to provide the topographic data needed to fit harvest and transportation designs to specific terrain. SKYTOWER and SKYMOBILE are integral programs in the PLANS package and are used to design the timber-harvest units for skyline systems. SKYTOWER determines skyline payloads and...

  15. 78 FR 19799 - United States Mint Kids' Baseball Coin Design Challenge

    Science.gov (United States)

    2013-04-02

    ... United States Mint National Baseball Hall of Fame Commemorative Coin Program Design Competition, which is a national competition for individuals 14 or older to create the design for the common obverse..., pencil, charcoal, marker, spray paint, crayon, ] pastels, or digital software. All contestants...

  16. Meta-model Based Model Organization and Transformation of Design Pattern Units in MDA

    Institute of Scientific and Technical Information of China (English)

    Chang-chun YANG; Zi-yi ZHAO; Jing Sun

    2010-01-01

    Tb achieve the purpose of applying design patterns which are various in kind and constant in changing in MDA from idea and application,one way is used to solve the problem of pattern disappearance which occurs at the process of pattern instantiation,to guarantee the independenceJpatterns,and at the same time,to apply this process to miltiple design patterns.Ib solve these two problems,the modeling method of design pattern units based on seta-models is adopted,I.e.,to divide the basic operations into atones in the metamodel tier and then combine the atones to complete design pattern units seta-models without business logic.After one process of conversion,the kxupose of making up various pattern units seta-model and dividing business logic and pattern logic is achieved.

  17. Improved simulation design factors for unconventional crude vacuum units : cracked gas make and stripping section performance

    Energy Technology Data Exchange (ETDEWEB)

    Remesat, D. [Koch-Glitsch Canada LP, Calgary, AB (Canada)

    2008-10-15

    Operating data for unconventional heavy oil vacuum crude units were reviewed in order to optimize the design of vacuum columns. Operational data from heavy crude vacuum units operating with stripping and velocity were used to investigate the application of a proven vacuum distillation tower simulation topology designed for use with heavy oil and bitumen upgrader feeds. Design factors included a characterization of the crude oils or bitumens processed in the facility; the selection of thermodynamic models; and the non-equilibrium simulation topology. Amounts of generated cracked gas were calculated, and entrainment and stripping section performance was evaluated. Heater designs for ensuring the even distribution of heat flux were discussed. Data sets from vacuum units processing crude oils demonstrated that the amount of offgas flow increased as the transfer line temperature increased. The resulting instability caused increased coke generation and light hydrocarbon formation. Results also indicated that overhead vacuum ejector design and size as well as heat transfer capabilities of quench and pumparound zones must be considered when designing vacuum column units. Steam stripping lowered hydrocarbon partial pressure to allow materials to boil at lower temperatures. It was concluded that setting appropriate entrainment values will ensure the accuracy of sensitivity analyses for transfer line designs, inlet feed devices, and wash bed configurations. 9 refs., figs.

  18. Profile of antimicrobial susceptibility isolated microorganisms from hospitalized patients in PICU ward and detection of Methicillin-resistant Staphylococcus aureus and ESBL-producing bacteria by phenotypic methods

    Directory of Open Access Journals (Sweden)

    Shahla Abbas Poor

    2014-10-01

    Full Text Available Background: Hospital-acquired infections are a major challenge to patient. A range of gram-negative organisms are responsible for hospital-acquired infections, the Enterobacteriaceae family being the most commonly identified group overall. Infections by ESBL producers are associated with severe adverse clinical outcomes that have led to increased mortality, prolonged hospitalization, and rising medical costs. The aim of this study was to survey profile of antimicrobial susceptibility isolated microorganisms from hospitalized patients in PICU ward and detection of methicillin-resistant Staphylococcus aureus and ESBL-producing bacteria by phenotypic methods. Material and Methods: In this study participants were patients hospitalized in PICU part of Bahrami Hospital, Tehran, with attention to involved organ. For isolation of bacteria from patient’s samples, culture performed on different selective and differential media. After confirmation of bacteria by biochemical tests, susceptibility testing was performed by disc diffusion method. Phenotypic detection of MRSA strains was performed using cefoxcitin disc. ESBL producing strains were detected by ceftazidime (CAZ and ceftazidime/clavulanic acid (CAZ/CLA discs. Results: Among all isolated organisms from clinical samples, the most common isolated organisms were Escherichia coli (24 cases, Pseudomonas areoginosa (9 cases and Staphylococcus aureus (8 cases, respectively. Among eight MRSA isolated strains from different clinical samples, six strains (75% were MRSA. Among 52 isolated gram negative organisms, 5 strains (9/6% were ESBL. Conclusion: Standard interventions to prevent the transmission of antimicrobial resistance in health care facilities include hand hygiene, using barrier precautions in the care of colonized and infected patients, using dedicated instruments and equipment for these patients. The colonized or infected patients should be isolated in single rooms, multibed rooms or areas

  19. Modeling and design of a combined transverse and axial flow threshing unit for rice harvesters

    Directory of Open Access Journals (Sweden)

    Zhong Tang

    2014-11-01

    Full Text Available The thorough investigation of both grain threshing and grain separating processes is a crucial consideration for effective structural design and variable optimization of the tangential flow threshing cylinder and longitudinal axial flow threshing cylinder composite units (TLFC unit of small and medium-sized (SME combine harvesters. The objective of this paper was to obtain the structural variables of a TLFC unit by theoretical modeling and experimentation on a tangential flow threshing cylinder unit (TFC unit and longitudinal axial flow threshing cylinder unit (LFC unit. Threshing and separation equations for five types of threshing teeth (knife bar, trapezoidal tooth, spike tooth, rasp bar, and rectangular bar, were obtained using probability theory. Results demonstrate that the threshing and separation capacity of the knife bar TFC unit was stronger than the other threshing teeth. The length of the LFC unit was divided into four sections, with helical blades on the first section (0-0.17 m, the spike tooth on the second section (0.17-1.48 m, the trapezoidal tooth on the third section (1.48-2.91 m, and the discharge plate on the fourth section (2.91-3.35 m. Test results showed an un-threshed grain rate of 0.243%, un-separated grain rate of 0.346%, and broken grain rate of 0.184%. Evidenced by these results, threshing and separation performance is significantly improved by analyzing and optimizing the structure and variables of a TLFC unit. The results of this research can be used to successfully design the TLFC unit of small and medium-sized (SME combine harvesters.

  20. A cost-effective methodology for the design of massively-parallel VLSI functional units

    Science.gov (United States)

    Venkateswaran, N.; Sriram, G.; Desouza, J.

    1993-01-01

    In this paper we propose a generalized methodology for the design of cost-effective massively-parallel VLSI Functional Units. This methodology is based on a technique of generating and reducing a massive bit-array on the mask-programmable PAcube VLSI array. This methodology unifies (maintains identical data flow and control) the execution of complex arithmetic functions on PAcube arrays. It is highly regular, expandable and uniform with respect to problem-size and wordlength, thereby reducing the communication complexity. The memory-functional unit interface is regular and expandable. Using this technique functional units of dedicated processors can be mask-programmed on the naked PAcube arrays, reducing the turn-around time. The production cost of such dedicated processors can be drastically reduced since the naked PAcube arrays can be mass-produced. Analysis of the the performance of functional units designed by our method yields promising results.

  1. Newman Unit 1 advanced solar repowering advanced conceptual design. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-04-01

    The Newman Unit 1 solar repowering design is a water/steam central receiver concept supplying superheated steam. The work reported is to develop a refined baseline conceptual design that has potential for construction and operation by 1986, makes use of existing solar thermal technology, and provides the best economics for this application. Trade studies performed in the design effort are described, both for the conceptual design of the overall system and for the subsystem conceptual design. System-level functional requirements, design, operation, performance, cost, safety, environmental, institutional, and regulatory considerations are described. Subsystems described include the collector, receiver, fossil energy, electrical power generating, and master control subsystems, site and site facilities. The conceptual design, cost, and performance of each subsystem is discussed at length. A detailed economic analysis of the repowered unit is made to realistically assess the economics of the first repowered unit using present cost data for a limited production level for solar hardware. Finally, a development plan is given, including the design, procurement, construction, checkout, startup, performance validation, and commercial operation. (LEW)

  2. Construction and psychometric testing of the EMPATHIC questionnaire measuring parent satisfaction in the pediatric intensive care unit

    NARCIS (Netherlands)

    Latour, Jos M.; van Goudoever, Johannes B.; Duivenvoorden, Hugo J.; Albers, Marcel J. I. J.; van Dam, Nicolette A. M.; Dullaart, Eugenie; van Heerde, Marc; de Neef, Marjorie; Verlaat, Carin W. M.; van Vught, Elise M.; Hazelzet, Jan A.

    2011-01-01

    To construct and test the reliability and validity of the EMpowerment of PArents in THe Intensive Care (EMPATHIC) questionnaire measuring parent satisfaction in the pediatric intensive care unit (PICU). Structured development and psychometric testing of a parent satisfaction-with-care instrument wit

  3. A qualitative study exploring the experiences of parents of children admitted to seven Dutch pediatric intensive care units

    NARCIS (Netherlands)

    Latour, Jos M.; van Goudoever, Johannes B.; Schuurman, Beatrix Elink; Albers, Marcel J. I. J.; van Dam, Nicolette A. M.; Dullaart, Eugenie; van Heerde, Marc; Verlaat, Carin W. M.; van Vught, Elise M.; Hazelzet, Jan A.

    2011-01-01

    To explore parents' experiences during the admission of their children to a pediatric intensive care unit (PICU). Qualitative method using in-depth interviews. Thematic analysis was applied to capture parents' experiences. Thirty-nine mothers and 25 fathers of 41 children admitted to seven of the ei

  4. Mortality in very long-stay pediatric intensive care unit patients and incidence of withdrawal of treatment

    NARCIS (Netherlands)

    S. Naghib (Sara); C. van der Starre (Cynthia); S.J. Gischler (Saskia); K.F.M. Joosten (Koen); D. Tibboel (Dick)

    2010-01-01

    textabstractBackground: The mortality for children with prolonged stay in pediatric intensive care units (PICU) is much higher than overall mortality. The incidence of withdrawal or limitation of therapy in this group is unknown. Purpose: To assess mortality and characteristics of children admitted

  5. A qualitative study exploring the experiences of parents of children admitted to seven Dutch pediatric intensive care units

    NARCIS (Netherlands)

    J.M. Latour (Jos); J.B. van Goudoever (Hans); B.E. Schuurman (Beatrix); M.J.I.J. Albers (Marcel); N.A.M. van Dam (Nicolette); E. Dullaart (Eugenie); M. van Heerde (Marc); C.W.M. Verlaat (Carin); E.M. van Vught (Elise); J.A. Hazelzet (Jan)

    2011-01-01

    textabstractPurpose: To explore parents' experiences during the admission of their children to a pediatric intensive care unit (PICU). Method: Qualitative method using in-depth interviews. Thematic analysis was applied to capture parents' experiences. Thirty-nine mothers and 25 fathers of 41 childre

  6. Construction and psychometric testing of the EMPATHIC questionnaire measuring parent satisfaction in the pediatric intensive care unit

    NARCIS (Netherlands)

    J.M. Latour (Jos); J.B. van Goudoever (Hans); H.J. Duivenvoorden (Hugo); M.J.I.J. Albers (Marcel); N.A.M. van Dam (Nicolette); E. Dullaart (Eugenie); M. van Heerde (Marc); M. de Neef (Marjorie); C.W.M. Verlaat (Carin); E.M. van Vught (Elise); J.A. Hazelzet (Jan)

    2011-01-01

    textabstractAbstract PURPOSE: To construct and test the reliability and validity of the EMpowerment of PArents in THe Intensive Care (EMPATHIC) questionnaire measuring parent satisfaction in the pediatric intensive care unit (PICU). METHODS: Structured development and psychometric testing of a paren

  7. What is the role of the physiotherapist in paediatric intensive care units? A systematic review of the evidence for respiratory and rehabilitation interventions for mechanically ventilated patients.

    Science.gov (United States)

    Hawkins, Ellie; Jones, Anne

    2015-12-01

    Physiotherapy in intensive care units (ICU) has traditionally focussed on the respiratory management of mechanically ventilated patients. Gradually, focus has shifted to include rehabilitation in adult ICUs, though evidence of a similar shift in the paediatric ICU (PICU) is limited. Review the evidence to determine the role of physiotherapists in the management of mechanically ventilated patients in PICU. A search was conducted of: PEDro, CINAHL, Medline, PubMed and the Cochrane Library. Studies involving PICU patients who received physiotherapy while invasively ventilated were included in this review. Those involving neonatal or adult ICU patients, or patients on non-invasive or long-term ventilation, were not included in the study. All articles were critically appraised by two reviewers and results were analysed descriptively. Six studies on chest physiotherapy (CPT) met the selection criteria. Results support the use of the expiratory flow increase technique and CPT, especially manual hyperinflation and vibrations, for secretion clearance. Evidence does not support the routine use of either CPT or suction alone. No studies investigating rehabilitation in PICU met selection criteria. A lack of high level evidence was available to inform this review. Evidence indicates that CPT is still the focus of physiotherapy intervention in PICU for mechanically ventilated patients, and supports its use for secretion clearance in this setting. PROSPERO register for systematic reviews (registration no. CRD42014009582). Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  8. Experience in design and startup of distillation towers in primary crude oil processing unit

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, Y.N.; D' yakov, V.G.; Mamontov, G.V.; Sheinman, V.A.; Ukhin, V.V.

    1985-11-01

    This paper describes a refinery in the city of Mathura, India, with a capacity of 7 million metric tons of crude per year, designed and constructed to include the following units: AVT for primary crude oil processing; catalytic cracking; visbreaking; asphalt; and other units. A diagram of the atmospheric tower with stripping sections is shown, and the stabilizer tower is illustrated. The startup and operation of the AVT and visbreaking units are described, and they demonstrate the high reliability and efficiency of the equipment.

  9. The Design of Treatment Wetlands in the United Kingdom: Successes, Failures, and Alternative Approaches

    Institute of Scientific and Technical Information of China (English)

    SUN Guangzhi; ZHANG Guangxin

    2008-01-01

    Constructed wetland was first introduced into the United Kingdom in the middle of 1980s, following a visit by a group of scientist to Western Germany. In the past 2 decades, the applications of constructed wetlands in this country have expanded substantially, due to the demand for green technologies and rising cost of fossil fuel energies. This paper reported a statistical investigation of the performances of 78 horizontal flow wetlands, representatives of such system in the United Kingdom. Alternative design equations, based on organic matter removal efficiency, have been developed from Monod kinetics, and the accuracy and reliability of current and alternative design approaches have been examined.

  10. 77 FR 60481 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Post-Accident...

    Science.gov (United States)

    2012-10-03

    ... COMMISSION Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Post-Accident..., and Testing Criteria for Air Filtration and Adsorption Units of Post-accident Engineered-Safety... design, inspection, and testing of air filtration and iodine adsorption units of...

  11. Prior antimicrobial therapy in the hospital and other predisposing factors influencing the usage of antibiotics in a pediatric critical care unit

    Directory of Open Access Journals (Sweden)

    Tsorva Athina

    2004-04-01

    Full Text Available Abstract Background The aim of this study was to determine whether prior antimicrobial therapy is an important risk factor for extended antimicrobial therapy among critically ill children. To evaluate other predisposing factors influencing the usage of antibiotics in a pediatric intensive care unit (PICU setting. To examine the relationship between the extent of antimicrobial treatment and the incidence of nosocomial infections and outcome. Methods This prospective observational cohort study was conducted at a university-affiliated teaching hospital (760 beds in Athens. Clinical data were collected upon admission and on each consecutive PICU day. The primary reason for PICU admission was recorded using a modified classification for mutually exclusive disease categories. All administered antibiotics to the PICU patients were recorded during a six-month period. Microbiological and pharmacological data were also collected over this period. The cumulative per patient and the maximum per day numbers of administered antibiotics, as well as the duration of administration were related to the following factors: Number of antibiotics which the patients were already receiving the day before admission, age groups, place of origin, the severity of illness, the primary disease and its complications during the course of hospitalization, the development of nosocomial infections with positive cultures, the presence of chronic disease or immunodeficiency, various interventional techniques (mechanical ventilation, central catheters, and PICU outcome. Results During a six-month period 174 patients were admitted to the PICU and received antibiotics for a total of 950 days (62.3% of the length of stay days. While in PICU, 34 patients did not receive antimicrobial treatment (19.5%, 69 received one antibiotic (39.7%, 42 two (24.1%, 17 three (9.8%, and 12 more than three (6.9%. The number of antibiotics prescribed in PICU or at discharge did not differ from that at

  12. Review of design conditions applicable to offshore wind energy systems in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Manwell, J.F.; Elkinton, C.N.; Rogers, A.L.; McGowan, J.G. [Renewable Energy Research Laboratory, Department of Mechanical and Industrial Engineering, University of Massachusetts, P.O. Box 32210, Amherst, MA 01003-2210 (United States)

    2007-02-15

    Offshore wind turbines are now being considered for use in the United States. Ensuring proper design of offshore wind turbines and wind farms requires knowledge of the external conditions in which the turbines and associated facilities are to operate. The primary external conditions are due to the wind and waves. Also, for many locations, floating ice will also be a major factor in the design. This review examines the following aspects of external conditions for the design of offshore wind turbines for the United States: (1) design requirements, (2) available offshore data sources, (3) data estimation and extrapolation techniques, (4) on-site data collection, and (5) likely sources of extreme events, including hurricanes and northeast storms. (author)

  13. Semiconductor laser diodes and the design of a D.C. powered laser diode drive unit

    OpenAIRE

    Cappuccio, Joseph C., Jr.

    1988-01-01

    Approved for public release; distribution is unlimited This thesis addresses the design, development and operational analysis of a D.C. powered semiconductor laser diode drive unit. A laser diode requires an extremely stable power supply since a picosecond spike of current or power supply switching transient could result in permanent damage. The design offers stability and various features for operational protection of the laser diode. The ability to intensity modulate (analog) and pulse m...

  14. Lightweight, Space and Power Efficient Solar Array Drive Design Implemented within Remote Interface Unit

    Science.gov (United States)

    Kivikyto, Tatu; Laaksoen, Jyrki

    2014-08-01

    PATRIA has implemented highly educated Remote Interface Units in various ESA missions. For the Sentinel-2 and EarthCARE it was constructed also to include Solar Array Drive Electronics. The same control design as for Solar Array Drive function was also piggybacked in Magneto Torque control drives and other mission specific stepper motor drives. The purpose of this paper is to summarise and present the PATRIA Solar Array Drive Electronics design advantages.

  15. Semiconductor laser diodes and the design of a D.C. powered laser diode drive unit

    OpenAIRE

    Cappuccio, Joseph C., Jr.

    1988-01-01

    Approved for public release; distribution is unlimited This thesis addresses the design, development and operational analysis of a D.C. powered semiconductor laser diode drive unit. A laser diode requires an extremely stable power supply since a picosecond spike of current or power supply switching transient could result in permanent damage. The design offers stability and various features for operational protection of the laser diode. The ability to intensity modulate (analog) and pulse m...

  16. Determination of prevalence and causes of hyponatremia in patient's admitted in pediatric intensive care unit of the Children's Hospital Medical Center

    Directory of Open Access Journals (Sweden)

    Kadivar M

    1999-06-01

    Full Text Available Among the 708 patients who were admitted in the pediatric intensive care unit (PICU of the children's hospital medical center, there were 100 patients with hyponatermia (Na<130 mEq/L. 62% of these patients had hyponatermia at the beginning of admission and 38% during hospitalization in PICU. According to the classification of hyponatermia in comparison to body fluid, this study revealed 7% pseudohyponatermia, 40% euvolemic hyponatermia, 34% hypovolemic hyponatermia and 10% hypovolemic hyponatermia. In conclusion, the most perevalent causes of hyponatermia in this study were syndrome of inappropriate antidiuretic hormone secretion (SIADH (27%, water intoxication (22% and extrarenal losses (20%

  17. The design and practice of giant hydro-turbine generating units of Three Gorges Project%The design and practice of giant hydro-turbine generating units of Three Gorges Project

    Institute of Scientific and Technical Information of China (English)

    Shao Jianxiong; Liu Jingwang; Yuan Dafu

    2011-01-01

    The main technical problems that should be considered in the design of hydro-turbine generating units of Three Gorges Project (TGP) are analyzed;the key technical researches performed are summarized, and the parameters of hydro-turbine generating units are optimized through the study on key technical problems. The unit operation indicates that the performance of the hydro-turbine generating units is excellent, and the units can operate in a safe, stable and highly efficient mode for a long term. Therefore, it is verified effectively that the general technical design of units is scientific and rational.

  18. HAL/SM system functional design specification. [systems analysis and design analysis of central processing units

    Science.gov (United States)

    Ross, C.; Williams, G. P. W., Jr.

    1975-01-01

    The functional design of a preprocessor, and subsystems is described. A structure chart and a data flow diagram are included for each subsystem. Also a group of intermodule interface definitions (one definition per module) is included immediately following the structure chart and data flow for a particular subsystem. Each of these intermodule interface definitions consists of the identification of the module, the function the module is to perform, the identification and definition of parameter interfaces to the module, and any design notes associated with the module. Also described are compilers and computer libraries.

  19. Towards the formal verification of the requirements and design of a processor interface unit

    Science.gov (United States)

    Fura, David A.; Windley, Phillip J.; Cohen, Gerald C.

    1993-01-01

    The formal verification of the design and partial requirements for a Processor Interface Unit (PIU) using the Higher Order Logic (HOL) theorem-proving system is described. The processor interface unit is a single-chip subsystem within a fault-tolerant embedded system under development within the Boeing Defense and Space Group. It provides the opportunity to investigate the specification and verification of a real-world subsystem within a commercially-developed fault-tolerant computer. An overview of the PIU verification effort is given. The actual HOL listing from the verification effort are documented in a companion NASA contractor report entitled 'Towards the Formal Verification of the Requirements and Design of a Processor Interface Unit - HOL Listings' including the general-purpose HOL theories and definitions that support the PIU verification as well as tactics used in the proofs.

  20. The design of a photodetector unit of a new Shashlyk EM calorimeter for COMPASS II

    Science.gov (United States)

    Chirikov-Zorin, I.; Krumshtein, Z.; Olchevski, A.

    2016-07-01

    A nine-channel photodetector unit with micropixel avalanche photodiodes (MAPD) and precision thermostabilization based on the compact Peltier module is designed and constructed. MAPD-3N with a high pixel density of 15,000 per square mm and area 3×3 mm2 produced by Zecotek were used.

  1. Towards the formal specification of the requirements and design of a processor interface unit

    Science.gov (United States)

    Fura, David A.; Windley, Phillip J.; Cohen, Gerald C.

    1993-01-01

    Work to formally specify the requirements and design of a Processor Interface Unit (PIU), a single-chip subsystem providing memory interface, bus interface, and additional support services for a commercial microprocessor within a fault-tolerant computer system, is described. This system, the Fault-Tolerant Embedded Processor (FTEP), is targeted towards applications in avionics and space requiring extremely high levels of mission reliability, extended maintenance free operation, or both. The approaches that were developed for modeling the PIU requirements and for composition of the PIU subcomponents at high levels of abstraction are described. These approaches were used to specify and verify a nontrivial subset of the PIU behavior. The PIU specification in Higher Order Logic (HOL) is documented in a companion NASA contractor report entitled 'Towards the Formal Specification of the Requirements and Design of a Processor Interfacs Unit - HOL Listings.' The subsequent verification approach and HOL listings are documented in NASA contractor report entitled 'Towards the Formal Verification of the Requirements and Design of a Processor Interface Unit' and NASA contractor report entitled 'Towards the Formal Verification of the Requirements and Design of a Processor Interface Unit - HOL Listings.'

  2. Design of a large dynamic range readout unit for the PSD detector of DAMPE

    CERN Document Server

    Zhou, Yong; Sun, Zhiyu; Zhang, Yongjie; Fang, Fang; Chen, Junling; Hu, Bitao

    2016-01-01

    A large dynamic range is required by the Plastic Scintillator Detector (PSD) of DArk Matter Paricle Explorer (DAMPE), and a double-dynode readout has been developed. To verify this design, a prototype detector module has been constructed and tested with cosmic rays and heavy ion beams. The results match with the estimation and the readout unit could easily cover the required dynamic range.

  3. Authoring Game-Based Adaptive Units of Learning with IMS Learning Design and

    OpenAIRE

    Burgos, Daniel; Moreno-Ger, Pablo; Sierra, José Luis; Fernández Manjón, Baltasar; Koper, Rob

    2007-01-01

    Burgos, D., Moreno-Ger, P., Sierra, J. L., Fernández Manjón, B., & Kooper, R. (2007). Authoring Game-Based Adaptive Units of Learning with IMS Learning Design and . International Journal of Learning Technology, 3(3), 252-268.

  4. A Game-Based Adaptive Unit of Learning with IMS Learning Design and

    NARCIS (Netherlands)

    Moreno-Ger, Pablo; Burgos, Daniel; Sierra, José Luis; Manjón, Baltasar Fernández

    2008-01-01

    Moreno-Ger, P., Burgos, D., Sierra, J. L., & Manjón, B. F. (2007). A Game-Based Adaptive Unit of Learning with IMS Learning Design and . In E. Duval, R. Klamma & M. Wolpers, Creating New Learning Experience on a Global Scale, Second European Conference on Technology Enhanced Learning, E

  5. Authoring Game-Based Adaptive Units of Learning with IMS Learning Design and

    NARCIS (Netherlands)

    Burgos, Daniel; Moreno-Ger, Pablo; Sierra, José Luis; Fernández Manjón, Baltasar; Koper, Rob

    2007-01-01

    Burgos, D., Moreno-Ger, P., Sierra, J. L., Fernández Manjón, B., & Kooper, R. (2007). Authoring Game-Based Adaptive Units of Learning with IMS Learning Design and . International Journal of Learning Technology, 3(3), 252-268.

  6. [Design of modulating intermediate frequency electrotherapy system based on microcontroller unit].

    Science.gov (United States)

    Yu, Xuefei; Liu, Xianfeng; Peng, Daming

    2010-12-01

    This article is devoted to the design of a system for modulating intermediate frequency electrotherapy waveform output. Prescriptions with different output waveform combinations were produced using microcontroller unit (MCU). The rich output waveforms effectively improve tolerance of human adaptability and achieve a therapeutic effect.

  7. REDUNDANT ELECTRIC MOTOR DRIVE CONTROL UNIT DESIGN USING AUTOMATA-BASED APPROACH

    Directory of Open Access Journals (Sweden)

    Yuri Yu. Yankin

    2014-11-01

    Full Text Available Implementation of redundant unit for motor drive control based on programmable logic devices is discussed. Continuous redundancy method is used. As compared to segregated standby redundancy and whole system standby redundancy, such method provides preservation of all unit functions in case of redundancy and gives the possibility for continuous monitoring of major and redundant elements. Example of that unit is given. Electric motor drive control channel block diagram contains two control units – the major and redundant; it also contains four power supply units. Control units programming was carried out using automata-based approach. Electric motor drive control channel model was developed; it provides complex simulation of control state-machine and power converter. Through visibility and hierarchy of finite state machines debug time was shortened as compared to traditional programming. Control state-machine description using hardware description language is required for its synthesis with FPGA-devices vendor design software. This description was generated automatically by MATLAB software package. To verify results two prototype control units, two prototype power supply units, and device mock-up were developed and manufactured. Units were installed in the device mock-up. Prototype units were created in accordance with requirements claimed to deliverable hardware. Control channel simulation and tests results in the perfect state and during imitation of major element fault are presented. Automata-based approach made it possible to observe and debug control state-machine transitions during simulation of transient processes, occurring at imitation of faults. Results of this work can be used in development of fault tolerant electric motor drive control channels.

  8. Environmental design in acute care settings: a case study of a neurological rehabilitation unit.

    Science.gov (United States)

    McCunn, Lindsay J; Gifford, Robert

    2013-01-01

    The purpose of this case study was to examine environmental variables that lead to staff error in acute care settings: noise; lighting; ergonomics, furniture, and equipment; and patient room design and unit layout. Chaudhury, Mahmood, & Valente (2009) reviewed a number of design considerations related to reducing errors by nursing staff in acute care settings. The Neurological Rehabilitation Unit (NRU) at one hospital served to further examine the design recommendations outlined by Chaudhury et al. (2009). Based on photographs, a site tour, interviews with the NRU manager and with the son of a patient of 5 months, comparisons were made between the NRU and the acute care setting design considerations reviewed by Chaudhury et al. (2009). The NRU appeared to comply with many recommendations: enforced noise reduction was facilitated through limiting both the number of patients per room and the number of patients admitted to the unit. Distinct rooms were used for various tasks that helped to contain activity-based noise. A combination of daylighting and artificial lighting was in place, but efforts to control glare and thermal comfort were not integrated into the design. The ergonomic needs of employees were incorporated in the design of the NRU, and the layouts of patient rooms and the layout of the NRU in general also were compatible with the design recommendations reviewed by Chaudhury et al. (2009). Many of the design attributes advocated by Chaudhury et al. (2009) were included in the NRU. Supplemental research should be undertaken, however, to objectively measure nursing error, efficiency, and staff satisfaction with respect to the comparisons and assumptions presented in this study. Case study, design, hospital, satisfaction, staff.

  9. Design and implementation of interface units for high speed fiber optics local area networks and broadband integrated services digital networks

    Science.gov (United States)

    Tobagi, Fouad A.; Dalgic, Ismail; Pang, Joseph

    1990-01-01

    The design and implementation of interface units for high speed Fiber Optic Local Area Networks and Broadband Integrated Services Digital Networks are discussed. During the last years, a number of network adapters that are designed to support high speed communications have emerged. This approach to the design of a high speed network interface unit was to implement package processing functions in hardware, using VLSI technology. The VLSI hardware implementation of a buffer management unit, which is required in such architectures, is described.

  10. Research on Key Technologies of Unit-Based CNC Machine Tool Assembly Design

    Directory of Open Access Journals (Sweden)

    Zhongqi Sheng

    2014-01-01

    Full Text Available Assembly is the part that produces the maximum workload and consumed time during product design and manufacturing process. CNC machine tool is the key basic equipment in manufacturing industry and research on assembly design technologies of CNC machine tool has theoretical significance and practical value. This study established a simplified ASRG for CNC machine tool. The connection between parts, semantic information of transmission, and geometric constraint information were quantified to assembly connection strength to depict the assembling difficulty level. The transmissibility based on trust relationship was applied on the assembly connection strength. Assembly unit partition based on assembly connection strength was conducted, and interferential assembly units were identified and revised. The assembly sequence planning and optimization of parts in each assembly unit and between assembly units was conducted using genetic algorithm. With certain type of high speed CNC turning center, as an example, this paper explored into the assembly modeling, assembly unit partition, and assembly sequence planning and optimization and realized the optimized assembly sequence of headstock of CNC machine tool.

  11. Design, development, fabrication and delivery of register and multiplexer units. [CMOS monolithic chip development

    Science.gov (United States)

    Feller, A.; Lombardi, T.

    1978-01-01

    Several approaches for implementing the register and multiplexer unit into two CMOS monolithic chip types were evaluated. The CMOS standard cell array technique was selected and implemented. Using this design automation technology, two LSI CMOS arrays were designed, fabricated, packaged, and tested for proper static, functional, and dynamic operation. One of the chip types, multiplexer register type 1, is fabricated on a 0.143 x 0.123 inch chip. It uses nine standard cell types for a total of 54 standard cells. This involves more than 350 transistors and has the functional equivalent of 111 gates. The second chip, multiplexer register type 2, is housed on a 0.12 x 0.12 inch die. It uses 13 standard cell types, for a total of 42 standard cells. It contains more than 300 transistors, the functional equivalent of 112 gates. All of the hermetically sealed units were initially screened for proper functional operation. The static leakage and the dynamic leakage were measured. Dynamic measurements were made and recorded. At 10 V, 14 megabit shifting rates were measured on multiplexer register type 1. At 5 V these units shifted data at a 6.6 MHz rate. The units were designed to operate over the 3 to 15 V operating range and over a temperature range of -55 to 125 C.

  12. Relation between safe use of medicines and Clinical Pharmacy Services at Pediatric Intensive Care Units

    Science.gov (United States)

    Okumura, Lucas Miyake; da Silva, Daniella Matsubara; Comarella, Larissa

    2016-01-01

    Abstract Objective: Clinical Pharmacy Services (CPS) are considered standard of care and is endorsed by the Joint Commission International, the American Academy of Pediatrics, and the American College of Clinical Pharmacy. In Brazil, single experiences have been discreetly arising and the importance of these services to children and adolescents care has led to interesting results, but certainly are under reported. This short report aims to discuss the effect of implementing a bedside CPS at a Brazilian Pediatric Intensive Care Unit (PICU). Methods: This is a cross-sectional study conducted in a 12 bed PICU community hospital, from Campo Largo/Brazil. Subjects with<18 years old admitted to PICU were included for descriptive analysis if received a CPS intervention. Results: Of 53 patients accompanied, we detected 141 preventable drug-related problems (DRPs) which were solved within clinicians (89% acceptance of all interventions). The most common interventions performed to improve drug therapy included: preventing incompatible intravenous solutions (21%) and a composite of inadequate doses (17% due to low, high and non-optimized doses). Among the top ten medications associated with DRPs, five were antimicrobials. By analyzing the correlation between DRPs and PICU length of stay, we found that 74% of all variations on length of stay were associated with the number of DRPs. Conclusions: Adverse drug reactions due to avoidable DRPs can be prevented by CPS in a multifaceted collaboration with other health care professionals, who should attempt to use active and evidence-based strategies to reduce morbidity related to medications. PMID:27578187

  13. Conceptual Design for the Pilot-Scale Plutonium Oxide Processing Unit in the Radiochemical Processing Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Lumetta, Gregg J.; Meier, David E.; Tingey, Joel M.; Casella, Amanda J.; Delegard, Calvin H.; Edwards, Matthew K.; Jones, Susan A.; Rapko, Brian M.

    2014-08-05

    This report describes a conceptual design for a pilot-scale capability to produce plutonium oxide for use as exercise and reference materials, and for use in identifying and validating nuclear forensics signatures associated with plutonium production. This capability is referred to as the Pilot-scale Plutonium oxide Processing Unit (P3U), and it will be located in the Radiochemical Processing Laboratory at the Pacific Northwest National Laboratory. The key unit operations are described, including plutonium dioxide (PuO2) dissolution, purification of the Pu by ion exchange, precipitation, and conversion to oxide by calcination.

  14. Diagnostic value of real-time polymerase chain reaction to detect viruses in young children admitted to the paediatric intensive care unit with lower respiratory tract infection

    NARCIS (Netherlands)

    van de Pol, Alma C; Wolfs, Tom F W; Jansen, Nicolaas J G; van Loon, Anton M; Rossen, John W A

    2006-01-01

    INTRODUCTION: The aetiology of lower respiratory tract infections in young children admitted to the paediatric intensive care unit (PICU) is often difficult to establish. However, most infections are believed to be caused by respiratory viruses. A diagnostic study was performed to compare convention

  15. The Amsterdam Studies of Acute Psychiatry –II (ASAP-II): a comparative study of psychiatric intensive care units in the Netherlands.

    NARCIS (Netherlands)

    Koppelmans, V.; Schoevers, R.A.; Wijk, van C.G.; Mulder, W.; Hornbach, A.; Barkhof, E.; Klaasen, A.; Egmond, van M.; Verlooij, van J.; Bijpost, Y.; Nusselder, H.; Herrewaarden, van M.; Maksimovic, I.; Achilles, A.; Dekker, J.J.M.

    2009-01-01

    Background The number of patients in whom mental illness progresses to stages in which acute, and often forced treatment is warranted, is on the increase across Europe. As a consequence, more patients are involuntarily admitted to Psychiatric Intensive Care Units (PICU). From several studies and

  16. The Amsterdam Studies of Acute Psychiatry - II (ASAP-II): a comparative study of psychiatric intensive care units in the Netherlands

    NARCIS (Netherlands)

    Koppelmans, V.; Schoevers, R.; van Wijk, C.G.; Mulder, W.; Hornbach, A.; Barkhof, E.; Klaassen, A.; van Egmond, M.; van Venrooij, J.; Bijpost, Y.; Nusselder, H.; van Herrewaarden, M.; Maksimovic, I.; Achilles, A.; Dekker, J.

    2009-01-01

    Background: The number of patients in whom mental illness progresses to stages in which acute, and often forced treatment is warranted, is on the increase across Europe. As a consequence, more patients are involuntarily admitted to Psychiatric Intensive Care Units (PICU). From several studies and

  17. Enhanced teaching and student learning through a simulator-based course in chemical unit operations design

    Science.gov (United States)

    Ghasem, Nayef

    2016-07-01

    This paper illustrates a teaching technique used in computer applications in chemical engineering employed for designing various unit operation processes, where the students learn about unit operations by designing them. The aim of the course is not to teach design, but rather to teach the fundamentals and the function of unit operation processes through simulators. A case study presenting the teaching method was evaluated using student surveys and faculty assessments, which were designed to measure the quality and effectiveness of the teaching method. The results of the questionnaire conclusively demonstrate that this method is an extremely efficient way of teaching a simulator-based course. In addition to that, this teaching method can easily be generalised and used in other courses. A student's final mark is determined by a combination of in-class assessments conducted based on cooperative and peer learning, progress tests and a final exam. Results revealed that peer learning can improve the overall quality of student learning and enhance student understanding.

  18. Design of the Wendelstein 7-X inertially cooled Test Divertor Unit Scraper Element

    Energy Technology Data Exchange (ETDEWEB)

    Lumsdaine, Arnold, E-mail: lumsdainea@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Boscary, Jean [Max Planck Institute for Plasma Physics, Garching (Germany); Fellinger, Joris [Max Planck Institute for Plasma Physics, Greifswald (Germany); Harris, Jeff [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Hölbe, Hauke; König, Ralf [Max Planck Institute for Plasma Physics, Greifswald (Germany); Lore, Jeremy; McGinnis, Dean [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Neilson, Hutch; Titus, Peter [Princeton Plasma Physics Lab, Princeton, NJ (United States); Tretter, Jörg [Max Planck Institute for Plasma Physics, Garching (Germany)

    2015-10-15

    Highlights: • The justification for the installation of the Test Divertor Unit Scraper Element is given. • Specially designed operational scenarios for the component are presented. • Plans for the design of the component are detailed. - Abstract: The Wendelstein 7-X stellarator is scheduled to begin operation in 2015, and to achieve full power steady-state operation in 2019. Computational simulations have indicated that for certain plasma configurations in the steady-state operation, the ends of the divertor targets may receive heat fluxes beyond their qualified technological limit. To address this issue, a high heat-flux “scraper element” (HHF-SE) has been designed that can protect the sensitive divertor target region. The surface profile of the HHF-SE has been carefully designed to meet challenging engineering requirements and severe spatial limitations through an iterative process involving physics simulations, engineering analysis, and computer aided design rendering. The desire to examine how the scraper element interacts with the plasma, both in terms of how it protects the divertor, and how it affects the neutral pumping efficiency, has led to the consideration of installing an inertially cooled version during the short pulse operation phase. This Test Divertor Unit Scraper Element (TDU-SE) would replicate the surface profile of the HHF-SE. The design and instrumentation of this component must be completed carefully in order to satisfy the requirements of the machine operation, as well as to support the possible installation of the HHF-SE for steady-state operation.

  19. PICU严重结核感染的临床特征与诊断%Clinical features and diagnosis of severe tuberculosis infection in PICU

    Institute of Scientific and Technical Information of China (English)

    戎群芳; 张育才; 徐梁; 陈容欣; 崔云; 王斐

    2014-01-01

    Objective To explore the clinical features and diagnostic methods of tuberculosis infection in PICU,and improve the understanding of tuberculosis.Methods We analysed the clinical features and diagnostic methods of severe tubercle bacillus infectious diseases in PICU from Jan 2009 to Dec 2012.Severity of disease was graded by pediatric critical illness score.The diagnosis of the pulmonary tuberculosis was in accord with the diagnostic criteria of paediatric pulmonary tuberculosis established by Chinese Medical Association paediatrics branch.And the diagnosis of tuberculosis meningitis and tuberculosis peritonitis based on the clinical physical examination,laboratory examination and pathologic finding.Results Among 22 cases enrolled in this study,totally 16 cases were pulmonary tuberculosis,6 cases were extrapulmonary tuberculosis,and 3 cases were tuberculosis meningitis.The clinical feature of severe tuberculosis infection in PICU was accompanying with one or multiple organ dysfunction besides tuberculosis infection symptom,among them,respiratory dysfunction occurred in 16 cases,cardiovascular dysfunction was observed in 2 cases,and central nervous system dysfunction was found in 3 cases,even 1 patient experienced cardiovascular system dysfunction,respiratory disorder as well as gastrointestinal system dysfunction simultaneously.Sixteen cases of pulmonary tubercle bacillus infection manifested respiratory failure besides fever,cough,shortness of breath and tuberculosis toxicosis symptom,2 cases of them developed into acute respiratory distress syndrome,8 cases needed mechanical ventilation.Two cases of pericardial effusion presented cardiac tamponade.The level of adenosine deaminase elevated in 12 cases,and the positive result of enzyme-linked immunospot assay for tubercle bacillius was observed in 14 cases.Conclusion It is very important to be aware of that severe tubercle bacillus infection exist in critically ill patients admitted in PICU,measuring the level of

  20. Urinary catheter related nosocomial infections in paediatric intensive care unit.

    Directory of Open Access Journals (Sweden)

    Tullu M

    1998-04-01

    Full Text Available The present prospective study was carried out in the Paediatric Intensive Care Unit (PICU of a tertiary care teaching hospital in Mumbai. The objective was to determine the incidence, risk factors, mortality and organisms responsible for urinary catheter related infections (UCRI. Colonization and/or bacteriuria was labelled as urinary catheter related infection (UCRI. Forty-four patients with 51 urinary catheters were studied. Incidence of UCRI was 47.06%. Age, female sex and immunocompromised status did not increase the risk of UCRI. Duration of catheter in-situ and duration of stay in the PICU were associated with higher risk of UCRI. The mortality was not increased by UCRI. Commonest organism isolated in UCRI was E. coli, which had maximum susceptibility to nitrofurantoin and amikacin.

  1. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation.

    Science.gov (United States)

    McGrath, Susan P; Taenzer, Andreas H; Karon, Nancy; Blike, George

    2016-07-01

    The growing number of monitoring devices, combined with suboptimal patient monitoring and alarm management strategies, has increased "alarm fatigue," which have led to serious consequences. Most reported alarm man- agement approaches have focused on the critical care setting. Since 2007 Dartmouth-Hitchcock (Lebanon, New Hamp- shire) has developed a generalizable and effective design, implementation, and performance evaluation approach to alarm systems for continuous monitoring in general care settings (that is, patient surveillance monitoring). In late 2007, a patient surveillance monitoring system was piloted on the basis of a structured design and implementation approach in a 36-bed orthopedics unit. Beginning in early 2009, it was expanded to cover more than 200 inpatient beds in all medicine and surgical units, except for psychiatry and labor and delivery. Improvements in clinical outcomes (reduction of unplanned transfers by 50% and reduction of rescue events by more than 60% in 2008) and approximately two alarms per patient per 12-hour nursing shift in the original pilot unit have been sustained across most D-H general care units in spite of increasing patient acuity and unit occupancy. Sample analysis of pager notifications indicates that more than 85% of all alarm conditions are resolved within 30 seconds and that more than 99% are resolved before escalation is triggered. The D-H surveillance monitoring system employs several important, generalizable features to manage alarms in a general care setting: alarm delays, static thresholds set appropriately for the prevalence of events in this setting, directed alarm annunciation, and policy-driven customization of thresholds to allow clinicians to respond to needs of individual patients. The systematic approach to design, implementation, and performance management has been key to the success of the system.

  2. Design of voice coil motor dynamic focusing unit for a laser scanner.

    Science.gov (United States)

    Lee, Moon G; Kim, Gaeun; Lee, Chan-Woo; Lee, Soo-Hun; Jeon, Yongho

    2014-04-01

    Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motors and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden-Fletcher-Goldfarb-Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.

  3. Designing a Prototype LPG Injection Electronic Control Unit for a Carburetted Gasoline Engine

    Directory of Open Access Journals (Sweden)

    Barış ERKUŞ

    2015-07-01

    Full Text Available In this study, the originally carburetted gasoline engine was converted to gas-phase liquefied petroleum gas (LPG injection engine by using an after market LPG conversion kit's components except the electronic control unit (ECU. Instead of after market LPG injection ECU, the ECU which was designed considering the effects of  electromagnetic interference (EMI, was used for controlling injection. The designed ECU was tested in terms of EMI while the engine was being run and it was detected that the EMI noises could be suppressed as possible by taken measures. Designed ECU was used in performance tests at different engine conditions and the results obtained with LPG injection were compared with the results obtained with LPG carburetion. According to the performance test results, LPG injection ECU designed in this study could help to achieve low exhaust emissions and high engine performance.  

  4. Designing a 100-unit Residential Complex with Public and Mental Health Approach

    Directory of Open Access Journals (Sweden)

    Mohsen Gholizadeh Maktoo

    2014-01-01

    Full Text Available The present study first discuses different climate conditions in Iran and traditional methods of architecture in these places as well as importance of identification and evaluation of these methods. Then, designing methods of residential complexes on the basis of components and conditions of the favorite climate will be closely taken into consideration. Finally, the impact of different methods and techniques of designing on society’s mental and public health will be examined. Accordingly, designing a 100-unit residential complex with open and local green spaces, dense neighborhoods with mixed land uses, physical and visual access to the nature, creation of cultural-social-business and entertainment opportunities adjacent to the residential complex, reducing car dependency in combination with walking, strategies of improving public health in designing residential complexes and architecture in Yazd city are used. Consequently, a few strategies are provided for enhancement of citizens’ health and development of this type of architecture.

  5. Design of a didactic unit: the energy; Diseno de una unidad didactica: la energia

    Energy Technology Data Exchange (ETDEWEB)

    Meneses V, J.A.; Caballero S, C. [Facultad de Educacion, Universidad de Burgos (Venezuela)

    2003-07-01

    In order to design didactic units a model is proposed which includes the following items: justify the subject of study, carry out a didactic approach and scientific analysis, specify the main principles, spell out the teaching materials and their sequence, define the teaching process and the activities programme, and finally to agree on the criteria and assessment strategies involved. An example of a lesson about the energy concept is shown. (Author)

  6. A Game-Based Adaptive Unit of Learning with IMS Learning Design and

    OpenAIRE

    Moreno-Ger, Pablo; Burgos, Daniel; Sierra, José Luis; Manjón, Baltasar Fernández

    2008-01-01

    Moreno-Ger, P., Burgos, D., Sierra, J. L., & Manjón, B. F. (2007). A Game-Based Adaptive Unit of Learning with IMS Learning Design and . In E. Duval, R. Klamma & M. Wolpers, Creating New Learning Experience on a Global Scale, Second European Conference on Technology Enhanced Learning, EC-TEL 2007 (pp. 247-261). September, 2007, Crete, Greece: Lecture Notes in Computer Science 4753 (Springer)

  7. Playful Politics: Developing a Framework for Designing Video Games for Political Participation in the United Kingdom

    Directory of Open Access Journals (Sweden)

    Andrew James Reid

    2015-11-01

    Full Text Available Political participation in the United Kingdom among young voters (aged 18-24 has steadily declined over the past two decades. Alongside this decline, video game popularity has meteorically risen among the same demographic, resulting in video games becoming increasingly more integrated within modern society. While these instances are not necessarily related, there is opportunity to explore the use of video games’ popularity to increase political participation.The basis of this research is to investigate video games as a medium for social change, and its application within a political context in order to encourage political participation in the United Kingdom. The research intends to critically analyse existing video game design theories with implications of social impact, such as transformative design, procedural rhetoric, ethical design, persuasive principles and the theory of play.This research has assisted in the development of the Political Design Framework, a design methodology that provides ethical definition and validation for video games that intend to promote political engagement.

  8. Design of a high-level waste repository system for the United States

    Energy Technology Data Exchange (ETDEWEB)

    Baeza, J.L.; Boerigter, S.T.; Broadbent, G.E.; Cabello, E.D.; Duran, V.B.; Hollaway, W.R.; Karlberg, R.P.; Siegel, M.J.; Simonson, S.A.

    1988-05-12

    This report presents a conceptual design for a High Level Waste disposal system for fuel discharged by US commercial power reactors, using the Yucca Mountain repository site recently designated by federal legislation. Principal features of the resulting conceptual design include use of unit trains for periodic removal of old spent fuel from at-reactor storage facilities, buffer storage at the repository site using dual purpose transportation/storage casks, repackaging of the spent fuel from the dual purpose transportation/storage casks directly into special-alloy disposal canisters as intact fuel assemblies, without rod consolidation, emplacement into a repository of modular design, use of excavation techniques that minimize disturbance, both mechanical and chemical, to the geologic environment, a unit rail mounted vehicle for both the transportation and emplacement of the canister from the surface facilities to the underground repository, and a cost-effectiveness computer model of Yucca Mountain and an independent cost evaluation by members of the design team. 31 refs., 58 figs., 15 tabs.

  9. Clinical Predictors of Intensive Care Unit Admission for Asthmatic Children

    Directory of Open Access Journals (Sweden)

    Mohammad Hasan Kargar Maher

    2015-07-01

    Full Text Available IntroductionChildren with severe asthma attack are a challenging group of patients who could be difficult to treat and leading to significant morbidity and mortality. Asthma attack severity is qualitatively estimated as mild, moderate and severe attacks and respiratory failure based on conditions such as respiration status, feeling of dyspnea, and the degree of unconsciousness. part of which are subjective rather than objective. We investigated clinical findings as predictors of severe attack and probable requirement for Pediatric Intensive Care Unit (PICU admission.Materials and MethodsIn a cross sectional and analytical study 120 patients with asthma attack were enrolled from April 2010 to April 2014 (80 admitted in the ward and 40 in pediatric intensive care unit. Predictors of PICU admission were investigated regarding to initial heart rate(HR, respiratory rate (RR, Arterial Oxygen Saturation(SaO2 and PaCo2 and clinically evident cyanosis.ResultsInitial heart rate(p-value=0.02, respiratory rate (p-value=0.03, Arterial Oxygen Saturation(p-value=0.02 and PaCo2(p-value=0.03 and clinically evident cyanosis were significantly different in two groups(Ward admitted and PICU admittedConclusion There was a significant correlation between initial vital sign and blood gas analysis suggesting usefulness of these factors as predictors of severe asthma attack and subsequent clinical course.

  10. Design and Evaluation of a Fully Implantable Control Unit for Blood Pumps

    Directory of Open Access Journals (Sweden)

    Kristin Unthan

    2015-01-01

    Full Text Available As the number of donor hearts is limited while more and more patients suffer from end stage biventricular heart failure, Total Artificial Hearts become a promising alternative to conventional treatment. While pneumatic devices sufficiently supply the patients with blood flow, the patient’s quality of life is limited by the percutaneous pressure lines and the size of the external control unit. This paper describes the development of the control unit of the ReinHeart, a fully implantable Total Artificial Heart. General requirements for any implantable control unit are defined from a technical and medical point of view: necessity of a Transcutaneous Energy Transmission, autonomous operation, safety, geometry, and efficiency. Based on the requirements, a prototype is designed; it incorporates a LiFePo4 battery pack with charger, a rectifier for transcutaneous energy transmission, the motor’s driver electronics, and a microcontroller which monitors and controls all functions. In validation tests, the control unit demonstrated a stable operation on TET and battery supply and a safe switching from one supply to the other. The overall mean efficiency is 14% on TET and 22% on battery supply. The control unit is suitable for chronic animal trials of the ReinHeart.

  11. Multi-Objective Optimization Design for Cooling Unit of Automotive Exhaust-Based Thermoelectric Generators

    Science.gov (United States)

    Qiang, J. W.; Yu, C. G.; Deng, Y. D.; Su, C. Q.; Wang, Y. P.; Yuan, X. H.

    2016-03-01

    In order to improve the performance of cooling units for automotive thermoelectric generators, a study is carried out to optimize the cold side and the fin distributions arranged on its inner faces. Based on the experimental measurements and numerical simulations, a response surface model of different internal structures is built to analyze the heat transfer and pressure drop characteristics of fluid flow in the cooling unit. For the fin distributions, five independent variables including height, length, thickness, space and distance from walls are considered. An experimental study design incorporating the central composite design method is used to assess the influence of fin distributions on the temperature field and the pressure drop in the cooling units. The archive-based micro genetic algorithm (AMGA) is used for multi-objective optimization to analyze the sensitivity of the design variables and to build a database from which to construct the surrogate model. Finally, improvement measures are proposed for optimization of the cooling system and guidelines are provided for future research.

  12. Creating healing intensive care unit environments: physical and psychological considerations in designing critical care areas.

    Science.gov (United States)

    Bazuin, Doug; Cardon, Kerrie

    2011-01-01

    A number of elements contribute to a healing ICU environment. The layout of a critical care unit helps create an environment that supports caregiving, which helps alleviate a host of work-related stresses. A quieter environment, one that includes family and friends, dotted with windows and natural light, creates a space that makes people feel balanced and reassured. A healing environment responds to the needs of all the people within a critical care unit-those who receive or give care and those who support patients and staff. Critical care units should be designed to focus on healing the body, the mind, and the senses. The design and policies of that department can be created in such a way to provide a sense of calm and balance. The physical environment has an impact on patient outcomes; the psychological environment can, too. A healing ICU environment will balance both. The authors discuss the ways in which architecture, interior design, and behavior contribute to a healing ICU environment.

  13. Design and simulation of an activated sludge unit associated to a continuous reactor to remove heavy metals

    Energy Technology Data Exchange (ETDEWEB)

    D`Avila, J.S.; Nascimento, R.R. [Ambientec Consultoria Ltda., Aracaju, SE (Brazil)

    1993-12-31

    A software was developed to design and simulate an activated sludge unit associated to a new technology to remove heavy metals from wastewater. In this process, a continuous high efficiency biphasic reactor operates by using particles of activated peat in conjugation with the sludge unit. The results obtained may be useful to increase the efficiency or to reduce the design and operational costs involved in a activated sludge unit. (author). 5 refs., 2 tabs.

  14. Nasogastric Tube Placement Errors and Complications in Pediatric Intensive Care Unit: A Case Report

    Directory of Open Access Journals (Sweden)

    Mahin Seyedhejazi

    2011-11-01

    Full Text Available Nasal ala pressure sores are among complications of nasogastric tube in Pediatric Intensive Care Unit (PICU. The severity of the injury is usually minor and easily ignored. However, the complication could be easily avoided. This is a case of nasal ala sore after the place-ment of nasal enteral tube in a pediatric intensive care unit in our center. A 5-month-old female with pulmonary hypertension secondary to bronchiectasis with nasal ala pressure sore were reported. She was hospitalized in pediatric intensive care unit at Tabriz Children Hospital in 2010.After 53 days of PICU hospitalization she had nasal ala sore. Conclusion: We know that nasal ala pressure sores could easily be avoided when preventive procedures were performed during nasogastric tube insertion.

  15. The Design Process of a Board Game for Exploring the Territories of the United States

    Directory of Open Access Journals (Sweden)

    Mehmet Kosa

    2017-06-01

    Full Text Available The paper reports the design experience of a board game with an educational aspect, which takes place on the location of states and territories of the United States. Based on a territorial acquisition dynamic, the goal was to articulate the design process of a board game that provides information for individuals who are willing to learn the locations of the U.S. states by playing a game. The game was developed using an iterative design process based on focus groups studies and brainstorming sessions. A mechanic-driven design approach was adopted instead of a theme or setting-driven alternative and a relatively abstract game was developed. The initial design idea was formed and refined according to the player feedback. The paper details play-testing sessions conducted and documents the design experience from a qualitative perspective. Our preliminary results suggest that the initial design is moderately balanced and despite the lack of quantitative evidence, our subjective observations indicate that participants’ knowledge about the location of states was improved in an entertaining and interactive way.

  16. Design of high-pressure direct contact heater for promising power supply units: Experimental substantiation

    Science.gov (United States)

    Somova, E. V.; Shvarts, A. L.; Turkin, A. V.

    2016-11-01

    The results of experimental studies of superheated steam condensation on feed water jets in a highpressure, direct-contact heat exchanger are presented. Direct contact feed water heater (DCFWH) can be used in a dual-flow diagram of a steam-power unit with ultrasupercritical steam parameters (35 MPa, 700/720°C). The direct contact feed water heater is included in the flow diagram of the II circuit in a promising power unit; it provides feed water heating to 340°C in all maintenance and emergency operation modes of the unit. The reliability of the high-pressure direct contact heater operation in this flow diagram is of major importance in relation to the danger of lead solidification in the tube space of the steam generator. Technical requirements to the design of the high-pressure direct contact heater for increasing the heat exchange efficiency are formulated based on the results of earlier studies with steam-water mixture as the heating medium. The results of studies of superheated steam condensation on jets presented in this study testify that feed water is additionally heated to the required temperature at the output of the installation. The influence of initial feed water parameters (outflow velocity and temperature) on the jet heating length is elucidated. The numerical approximation of the experimental data for determination of the jet heating length in the nominal and partial power unit loads is obtained. The results of the calculations are used to simplify the design of the water-supplying element for the direct contact feed water heater. The proposed design of direct contact feed water heater is characterized by simplicity and low metal intensity, which provides the installation reliability at the considered pressure level due to the minimum number of structural elements.

  17. Designing a better place for patients: professional struggles surrounding satellite and mobile dialysis units.

    Science.gov (United States)

    Lehoux, Pascale; Daudelin, Geneviève; Poland, Blake; Andrews, Gavin J; Holmes, Dave

    2007-10-01

    The professional claims and struggles involved in the design of non-traditional health care places are rarely problematized in applied health research, perhaps because they tend to fade away once the new design is implemented. This paper offers insights into such professional tensions and their impact on health care delivery by examining the design of two dialysis service delivery models in Quebec, Canada. The satellite units were hosted in two small hospitals and staffed by recently trained nurses. The mobile unit was a bus fitted to accommodate five dialysis stations. It was staffed by experienced nurses and travelled back and forth between a university teaching hospital and two sites. In both projects, nephrologists supervised from a distance via a videoconferencing system. In this paper, we draw mainly from interviews with managers (mostly nurses) and physicians (n=18), and from on-site observations. Nephrologists, medical internists, and managers all supported the goal of providing "closer-to-patient" services. However, they held varying opinions on how to best materialize this goal. By comparing two models involving different clinical and spatial logics, we underscore the ways in which the design of non-traditional health care places opens up space for the re-negotiation of clinical norms. Instead of relatively straightforward conflicts between professions, we observed subtle but inexorable tensions within and beyond professional groups, who sought to measure up to "ideal standards" while acknowledging the contingencies of health care places.

  18. Asthma changes at a Pediatric Intensive Care Unit after 10 years: Observational study

    Directory of Open Access Journals (Sweden)

    Ayman A Al-Eyadhy

    2015-01-01

    Full Text Available Objectives: To describe the change in the management, and outcome of children with acute severe asthma (ASA admitted to Pediatric Intensive Care Unit (PICU at tertiary institute, as compared to previously published report in 2003. Methods : This is a retrospective observational study. All consecutive pediatric ASA patients who were admitted to PICU during the study period were included. The data were extracted from PICU database and medical records. The Cohort in this study (2013 Cohort was compared with the Cohort of ASA, which was published in 2003 from the same institution (2003 Cohort. Results: In comparison to previous 2003 Cohort, current Cohort (2013 revealed higher mean age (5.5 vs. 3.6 years; P ≤ 0.001, higher rate of PICU admission (20.3% vs. 3.6%; P ≤ 0.007, less patients who received maintenance inhaled steroids (43.3% vs. 62.4%; P ≤ 0.03, less patients with pH <7.3 (17.9% vs. 42.9%; P ≤ 0.001. There were more patients in 2013 Cohort who received: Inhaled Ipratropium bromide (97% vs. 68%; P ≤ 0.001, intravenous magnesium sulfate (68.2% vs. none, intravenous salbutamol (13.6% vs. 3.6%; P ≤ 0.015, and noninvasive ventilation (NIV (35.8% vs. none while no patients were treated with theophylline (none vs. 62.5%. The median length of stay (LOS was 2 days while mean LOS was half a day longer in the 2013 Cohort. None of our patients required intubation, and there was no mortality. Conclusion: We observed slight shift toward older age, considerably increased the rate of PICU admission, increased utilization of Ipratropium bromide, magnesium sulfate, and NIV as important modalities of treatment.

  19. Effect of Gastric Acid Suppressant Prophylaxis on Incidence of Gastrointestinal Bleeding in Pediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Tahoora Abdollahi

    2016-11-01

    Full Text Available Background: Critically ill children admitted to pediatric intensive care unit (PICU are at increased risk of gastrointestinal bleeding due to stress related mucosal injury. Reducing gastric acid by acid suppressant medication is the accepted prophylaxis treatment, but there is not any definitive guideline for using prophylaxis in PICU patients. The present study aimed to assess the effect of Proton Pump Inhibitor (PPI and H2 Blocker (H2B prophylaxis on gastrointestinal bleeding in admitted patients of PICU, Mashhad- Iran.Materials and Methods: In this study, 100 patients admitted in PICU divided into two equal groups on the first day of admission. They received ranitidine or pantoprazole as prophylaxis of stress ulcer. Those patients who had history of gastrointestinal bleeding or coagulation disorder were excluded. 100 PICU patients who had not received prophylaxis during last 6 months retrospectively evaluated as control of the study. Data were collected as demographic characteristics, admission reason, definitive diagnosis, receiving corticosteroid and mechanical ventilation in each patient. Gastrointestinal bleeding (hematemesis, coffee ground aspirate, and melena and clinically significant gastrointestinal bleeding were daily monitored. Data analyzed through descriptive statistical tests, Chi-square, logistic regression, t-test and using SPSS-16 software.Results: Among 204 patients (control group=105 and case group=99, incidence of gastrointestinal bleeding (GB was 13.2% in which 6.9% of cases presented with clinically significant gastrointestinal bleeding (CSGB. Loss of consciousness and respiratory distress were the main reason of admission. There was no significant differences between the incidence of (GB and (CSGB in experimental and control groups (P>0.05 as well as ranitidine and pantoprazole prophylaxis (P>0.05. Significant risk factors of (GB were mechanical ventilation and loss of consciousness and corticosteroid therapy

  20. Designing an educative curriculum unit for teaching molecular geometry in high school chemistry

    Science.gov (United States)

    Makarious, Nader N.

    Chemistry is a highly abstract discipline that is taught and learned with the aid of various models. Among the most challenging, yet a fundamental topic in general chemistry at the high school level, is molecular geometry. This study focused on developing exemplary educative curriculum materials pertaining to the topic of molecular geometry. The methodology used in this study consisted of several steps. First, a diverse set of models were analyzed to determine to what extent each model serves its purpose in teaching molecular geometry. Second, a number of high school teachers and college chemistry professors were asked to share their experiences on using models in teaching molecular geometry through an online questionnaire. Third, findings from the comparative analysis of models, teachers’ experiences, literature review on models and students’ misconceptions, the curriculum expectations of the Next Generation Science Standards and their emphasis on three-dimensional learning and nature of science (NOS) contributed to the development of the molecular geometry unit. Fourth, the developed unit was reviewed by fellow teachers and doctoral-level science education experts and was revised to further improve its coherence and clarity in support of teaching and learning of the molecular geometry concepts. The produced educative curriculum materials focus on the scientific practice of developing and using models as promoted in the Next Generations Science Standards (NGSS) while also addressing nature of science (NOS) goals. The educative features of the newly developed unit support teachers’ pedagogical knowledge (PK) and pedagogical content knowledge (PCK). The unit includes an overview, teacher’s guide, and eight detailed lesson plans with inquiry oriented modeling activities replete with models and suggestions for teachers, as well as formative and summative assessment tasks. The unit design process serves as a model for redesigning other instructional units in

  1. Design and Implementation of 16-bit Arithmetic Logic Unit using Quantum dot Cellular Automata (QCA Technique

    Directory of Open Access Journals (Sweden)

    Rashmi Pandey

    2014-09-01

    Full Text Available Quantum Dot Cellular Automata (QCA is an advanced nanotechnology that attempts to create general computational at the nano-scale by controlling the position of single electrons. Quantum dot cellular automata (QCA defines a new device architecture that permits the innovative design of digital systems. QCA technology has large potential in terms of high space density and power dissipation with the development of the faster computer with smaller size & low power consumption.QCA help us to overcome the limitations of CMOS technology. In this paper, A design 16-bit arithmetic logic unit (ALU based on the Quantum dot cellular automata (QCA is presented. The simulation result of 16 bit ALU is verified using QCA Designer tool.

  2. Optimal design of compact organic Rankine cycle units for domestic solar applications

    DEFF Research Database (Denmark)

    Barbazza, Luca; Pierobon, Leonardo; Mirandola, Alberto

    2014-01-01

    Organic Rankine cycle turbogenerators are a promising technology to transform the solar radiation harvested by solar collectors into electric power. The present work aims at sizing a small-scale organic Rankine cycle unit by tailoring its design for domestic solar applications. Stringent design...... criteria, i.e., compactness, high performance and safe operation, are targeted by adopting a multi-objective optimization approach modeled with the genetic algorithm. Design-point thermodynamic variables, e.g., evaporating pressure, the working fluid, minimum allowable temperature differences....... Findings also suggest that the evaporator and condenser minimum allowable temperature differences have the largest impact on the system volume and on the cycle performances. Among the fluids considered, the results indicate that R1234yf and R1234ze are the best working fluid candidates. Using flat plate...

  3. An accomplished teacher's use of scaffolding during a second-grade unit on designing games.

    Science.gov (United States)

    Chen, Weiyun; Rovegno, Inez; Cone, Stephen L; Cone, Theresa P

    2012-06-01

    The purpose of this study was to describe how an accomplished teacher taught second-grade students to design games that integrated movement and mathematics content. The participants were one physical education teacher; a classroom teacher, and an intact class of 20 second-grade students. Qualitative data were gathered through videotaping of all lessons, descriptions of 20 children's responses to all lesson segments, and interviews with all participants. In keeping with constructivist principles, the teacher used a progression of tasks and multiple instructional techniques to scaffold the design process allowing children to design games that were meaningful to them. Contrary to descriptions of scaffolding fading across a unit, in this study the scaffolding was a function of the interaction between learners' needs and task content.

  4. Free and open source simulation tools for the design of power processing units for photovoltaic systems

    Directory of Open Access Journals (Sweden)

    Sergio Morales-Hernández

    2015-06-01

    Full Text Available Renewable energy sources, including solar photovoltaic, require electronic circuits that serve as interface between the transducer device and the device or system that uses energy. Moreover, the energy efficiency and the cost of the system can be compromised if such electronic circuit is not designed properly. Given that the electrical characteristics of the photovoltaic devices are nonlinear and that the most efficient electronic circuits for power processing are naturally discontinuous, a detailed dynamic analysis to optimize the design is required. This analysis should be supported by computer simulation tools. In this paper a comparison between two software tools for dynamic system simulation is performed to determinate its usefulness in the design process of photovoltaic systems, mainly in what corresponds to the power processing units. Using as a case of study a photovoltaic system for battery charging it was determined that Scicoslab tool was the most suitable.

  5. Design and Development of the Engine Unit for a Twin-Rotor Unmanned Aerial Vehicle

    Directory of Open Access Journals (Sweden)

    G. Avanzini

    2005-01-01

    Full Text Available Advanced computer-aided technologies played a crucial role in the design of an unconventional Uninhabited Aerial Vehicle (UAV, developed at the Turin Technical University and the University of Rome “La Sapienza”. The engine unit of the vehicle is made of a complex system of three two stroke piston engines coupled with two counter-rotating three-bladed rotors, controlled by rotary PWM servos. The focus of the present paper lies on the enabling technologies exploited in the framework of activities aimed at designing a suitable and reliable engine system, capable of performing the complex tasks required for operating the proposed rotorcraft. The synergic use of advanced computational tools for estimating the aerodynamic performance of the vehicle, solid modeling for mechanical components design, and rapid prototyping techniques for control system logic synthesis and implementation will be presented. 

  6. Design of Heat Exchanger Network for VCM Distillation Unit Using Pinch Technology

    Directory of Open Access Journals (Sweden)

    VISHAL G. BOKAN

    2015-06-01

    Full Text Available In process industries, heat exchanger networks represent an important part of the plant structure. The purpose of the networks is to maximize heat recovery, thereby lowering the overall plant costs. In process industries, during operation of any heat exchanger network (HEN, the major aim is to focus on the best performance of the network As in present condition of fuel crises is one of the major problem faced by many country & industrial utility is majorly depend on this. There is technique called process integration which is used for integrate heat within loop so optimize the given process and minimize the heating load and cooling load .In the present study of heat integration on VCM (vinyl chloride monomer distillation unit, Heat exchanger network (HEN is designed by using Aspen energy analyzer V8.0 software. This software implements a methodology for HEN synthesis with the use of pinch technology. Several heat integration networks are designed with different ΔT min and total annualized cost compared to obtain the optimal design. The network with a ΔT min of 90C is the most optimal where the largest energy savings are obtained with the appropriate use of utilities (Save 15.3764% for hot utilities and 47.52% for cold utilities compared with the current plant configuration. Percentage reduction in total operating cost is 18.333%. From calculation Payback Period for new design is 3.15 year. This save could be done through a plant revamp, with the addition of two heat exchangers. This improvement are done in the process associated with this technique are not due to the use of advance unit operation, but to the generation of heat integration scheme. The Pinch Design Method can be employed to give good designs in rapid time and with minimum data.

  7. Design of optimal operating conditions of simulated moving bed adsorptive separation units

    Energy Technology Data Exchange (ETDEWEB)

    Storti, G. (Univ. degli Studi di Padova (Italy)); Baciocchi, R.; Mazzotti, M.; Morbidelli, M. (Politecnico di Milano (Italy). Dipt. di Chimica Fisica Applicata)

    1995-01-01

    The design of the optimal operating conditions for simulated moving bed (SMB) adsorptive separation units is considered. A procedure for the a priori selection of the operating conditions to achieve an assigned separation requirement is developed in the frame of equilibrium theory for the equivalent four section countercurrent unit, using a model where the adsorption equilibria are described through the constant selectivity stoichiometric model, while both mass transfer resistance and axial dispersion are neglected. The space of the operating parameters, i.e. the mass flow rate ratios m[sub j], is divided in regions with different separation regimes. Curves at constant outlets purity and recovery are drawn in the (m[sub 2],m[sub 3]) plane. The introduction of three performance parameters, desorbent requirement, adsorbent requirement, and productivity, allows the development of a procedure for the design of optimal operating conditions. This procedure is completed, accounting for the effect of the switching time on the separation performances, with a detailed model of the SMB unit, considering both axial dispersion and mass transfer resistance. This result constitutes a useful tool for determining the range of operating conditions to achieve an assigned separation requirement and then for selecting the optimal operating condition within this range.

  8. Use of manganin-constantan thermocouples in thermometry units designed for copper-constantan thermocouples.

    Science.gov (United States)

    Hoh, L L; Waterman, F M

    1995-01-01

    Commercial ultrasound hyperthermia systems typically include thermometry units designed for copper-constantan thermocouples. Replacing these copper-constantan thermocouples with manganin-constantan thermocouples is advantageous in reducing the measurement error caused by the conduction of heat along the copper wire, but their performance in these thermometry units is uncertain. The accuracy of manganin-constantan thermocouples in the Labthermics LT-100, Clini-Therm TS1200/TM100, and Physitemp TM-12 thermometry units was investigated using a temperature controlled circulating water bath monitored by a mercury thermometer having a calibration traceable to NIST. The results demonstrate that an accuracy of +/- 0.2 degrees C can be achieved with manganin-constantan thermocouples over the range 35-55 degrees C without hardware modification provided specific calibration procedures are followed. With the Labthermics LT-100, a double point calibration should be carried out at 35 and 55 degrees C. With the Clini-Therm TS1200/TM100, a self-calibration of the unit using its internal calibration well plus a single point calibration using an external temperature standard provides sufficient accuracy. The Physitemp TM-12 requires an external computer for read out and the user must provide additional software to correct for the error by either a single or multiple point calibration.

  9. Maximizing water use efficiency in designing microirrigation unit (IrriLab Software)

    Science.gov (United States)

    Baiamonte, Giorgio

    2016-04-01

    As the year 2050 approaches, the world population will reach 9 billion - so does the challenge of doubling crop yields. To meet this crop yields demand, the associated dramatic improving of water productivity (WP) must necessarily be accompanied by maximization of water use efficiency (WUE) (Ragab 2011, UNEP 2014). In this work, a recently developed software (IrriLab, https://www.facebook.com/irrilab) moving in this direction is presented. IrriLab is a very simple toll allows to design microirrigation unit optimizing WUE, pressure energy and irrigation unit costs. Irrigation software available in commerce provide microirrigation system designs, by mainly looking at the maximum flow rate uniformity criteria. Thus, each emitter installed along the laterals operates with an operating pressure head occurring in between an established range of pressure head variability (Dh < Dhadm). However, the latter condition does not always corresponds to the cheapest and to the maximizing WUE solution; in fact, it is not assured if the entire range of the admitted pressure head is profited and used by the emitters. IrriLab allows this occurrence because, for the entire Irrigation Unit Area, IUA, each design solution assures that at least two emitters rigorously operates, one with the minimum admitted pressure head, and the other one with the maximum admitted (Dh = Dhadm), (Baiamonte et al., 2015; Baiamonte, 2016). The same extreme values of pressure head are those that in the common design criteria delimit the range of pressure head, but without assuring their achievement. Compared to the common design criteria, this condition i) for fixed laterals' length and inside diameter, allows reducing the inlet required pressure head whereas, ii) for fixed pressure head at the inlet, provides an increasing in laterals and manifold lengths and in the associated IUA. Based on analytical solutions, IrriLab follows a very simple rectangular sketch, any way oriented in the space, and defined by

  10. Design of a radiation surveillance unit for an unmanned aerial vehicle.

    Science.gov (United States)

    Kurvinen, K; Smolander, P; Pöllänen, R; Kuukankorpi, S; Kettunen, M; Lyytinen, J

    2005-01-01

    This paper describes a prototype of a compact environmental radiation surveillance instrument designed for a Ranger unmanned aerial vehicle. The instrument, which can be used for tracking a radioactive plume, mapping fallout and searching for point sources, consists of three different detector types (GM, NaI(Tl) and CZT) and an air sampling unit. In addition to the standard electronics for data acquisition, the system contains an onboard computer, a GPS receiver and environmental sensors, all enclosed in a single housing manufactured of fiberglass-reinforced composite material. The data collected during the flight is transmitted in real-time to the ground station via a TETRA radio network. The radiation surveillance unit is an independent module and as such can be used in, for example, airplanes, helicopters and cars.

  11. Etnobotânica de plantas medicinais em duas comunidades do município de Picuí, Paraíba, Brasil

    Directory of Open Access Journals (Sweden)

    J.C. COSTA

    2016-03-01

    Full Text Available RESUMO O presente trabalho realizou um levantamento etnobotânico sobre a utilização de plantas medicinais no município de Picuí, Seridó Oriental, Estado da Paraíba, Brasil. Foi analisada uma área urbana (bairro monte santo e uma rural (sítio massapê. As informações etnobotânicas foram obtidas através de formulários semiestruturados, contendo características socioeconômicas dos entrevistados, características das plantas e seus usos terapêuticos. Para a entrevista foi selecionado o adulto responsável pela residência, “chefe de família”, e utilizou-se a técnica da “bola de neve”. Foram citadas 37 famílias botânicas, 59 gêneros e 64 espécies. As espécies mais citadas foram Vernonia condensata Baker e Chenopodium ambrosioides L. e a família mais indicada foi Fabaceae. O hábito predominante foi o herbáceo, seguido do arbóreo; as partes da planta mais utilizadas foram as folhas e as cascas do caule; os principais modos de preparo dos remédios foram os chás e a água e/ou sumo. A planta com maior CUPc foi Vernonia condensata Baker (41,67%, sendo também uma das plantas com maior FRt junto a Chenopodium ambrosioides L., ambas com 19,6%. Esses resultados demonstraram que as populações estudadas ainda usam plantas medicinais com frequência, entretanto, a maioria das plantas utilizadas não é nativa da caatinga.

  12. The design of the electron beam dump unit of Turkish Accelerator Center (TAC)

    Science.gov (United States)

    Cite, L. H.; Yilmaz, M.

    2016-03-01

    The required simulations of the electron beam interactions for the design of electron beam dump unit for an accelerator which will operate to get two Infra-Red Free Electron Lasers (IR-FEL) covering the range of 3-250 microns is presented in this work. Simulations have been carried out to understand the interactions of a bulk of specially shaped of four different and widely used materials for the dump materials for a 77 pC, 40 MeV, 13 MHz repetition rate e-beam. In the simulation studies dump materials are chosen to absorb the 99% of the beam energy and to restrict the radio-isotope production in the bulk of the dump. A Lead shielding also designed around the dump core to prevent the leakage out of the all the emitted secondary radiations, e.g., neutrons, photons. The necessary dump material requirements, for the overall design considerations and the possible radiation originated effects on the dump unit, are discussed and presented.

  13. Didactical Design Material Units of Distance and Speed to Developed Mathematical Connection in Elementary School

    Science.gov (United States)

    Jannah, R. R.; Apriliya, S.; Karlimah

    2017-03-01

    This study aims to develop alternative instructional design based of barriers learning which identified by developing mathematical connection capabilities to the material unit of distance and speed. The research was conducted in the fifth grade elementary school Instructional design is complemented with a hypothetical learning trajectory in the form of a pedagogical didactic anticipation. The method used is descriptive method with qualitative approach. Techniques data collection used were observation, interviews, and documentation. The instrument used the researchers themselves are equipped with an instrument written test. The data were analyzed qualitatively to determine the student learning obstacles, then arrange hypothetical learning trajectory and pedagogical didactic anticipation. Learning obstacle are identified, it is learning obstacle related the connections between mathematical topics, learning obstacle related with other disciplines, and learning obstacle related with everyday life. The results of this research are improvement and development of didactic design in mathematics which has activities mathematical connection to the material unit of distance and speed in elementary school. The learning activities are carried out is using varied methods include method lectures, demonstrations, practice and exercise, as well as using the modified instructional media.

  14. Conceptual design of free-piston Stirling conversion system for solar power units

    Science.gov (United States)

    Loktionov, Iu. V.

    A conversion system has been conceptually designed for solar power units of the dish-Stirling type. The main design objectives were to demonstrate the possibility of attaining such performance characteristics as low manufacturing and life cycle costs, high reliability, long life, high efficiency, power output stability, self-balance, automatic (or self-) start-up, and easy maintenance. The system design includes a heat transfer and utilization subsystem with a solar receiver, a free-piston engine, an electric power generation subsystem, and a control subsystem. The working fluid is helium. The structural material is stainless steel for hot elements, aluminum alloys and plastics for others. The electric generation subunit can be fabricated in three options: with an induction linear alternator, with a permanent magnet linear alternator, and with a serial rotated induction generator and a hydraulic drive subsystem. The heat transfer system is based on heat pipes or the reflux boiler principle. Several models of heat transfer units using a liquid metal (Na or Na-K) have been created and demonstrated.

  15. Design of voice coil motor dynamic focusing unit for a laser scanner

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Moon G.; Kim, Gaeun; Lee, Chan-Woo; Lee, Soo-Hun; Jeon, Yongho, E-mail: princaps@ajou.ac.kr [Department of Mechanical Engineering, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon-si, Gyeonggi-do 443-749 (Korea, Republic of)

    2014-04-15

    Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motors and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden–Fletcher–Goldfarb–Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.

  16. 新型呼吸道病毒在PICU的检出及其临床意义%Detection and clinical characterization of emerging respiratory virus in PICU

    Institute of Scientific and Technical Information of China (English)

    林广裕; 蔡晓莹; 蔡志伟; 林创兴; 陈派镇; 周晓华; 肖泽曦; 陆学东

    2014-01-01

    Objective To describe the detection and clinical characterization of emerging respiratory virus in PICU.Methods Nasopharyngeal aspirates specimens(NPA) were collected from 600 children who were admitted to PICU with acute respiratory tract infection in our hospital.Additional 87 NPA were collected from healthy children for routine examination in the physical examination center.The clinical datas were collected.Multiplex PCR was applied to detect emerging respiratory virus.Some sequences were identified by using DNA sequencing.And the clinical data of positive cases were analysed.Results (1) There were 114 positive samples(19%) in 600 NPA,including 48(8.00%) human bocavirus(HBoV),47 (7.83%) human rhinovirus group C(HRV-C),13 (2.17%) swine H1N1 (SWH1N1),10 (1.67%) human metapneumovirs (HMPV),3 (0.50%) WU polyomaviruses (WUPyV).But none from 87 healthy controls were positive for any respiratory virus.(2) Co-infection by at least 2 viral pathogens under study was observed in 45 of the 114 positive cases,including 22 (45.83%,22/48) HBoV,14 (29.78%,14/47) HRV-C,4 (4/13) SWH1N1,9(9/10) HMPV,3 (3/3) WU polyomaviruses.Conclusion The emerging viruses,such as HBoV,HMPV,HRV-C,SWH1 N1,have high detection rate in PICU,may lead to severe infection.The clinical doctors should pay attention to them.%目的 了解新型呼吸道病毒在PICU中的检出情况及感染患儿的临床特点.方法 收集我院600例PICU急性呼吸道感染患儿的咽拭子标本600份,87例社区健康体检儿童咽拭子87份作为健康对照.应用多重PCR技术对新型呼吸道病毒进行检测,部分阳性结果进行基因测序,并分析阳性病例的临床资料.结果 (1) 600例患儿中,新型呼吸道病毒检测阳性114例(19%),其中人博卡病毒(human bocavirus,HBoV)48例(8.00%),C型鼻病毒(human rhinovirus group C,HRV-C)47例(7.83%),新型甲型流感H1N1病毒13例(2.17%),人偏肺病毒(human metapneumovirs,HMPV)10例(1.67%),WU多瘤病毒3例(0

  17. Multi-Mission System Architecture Platform: Design and Verification of the Remote Engineering Unit

    Science.gov (United States)

    Sartori, John

    2005-01-01

    The Multi-Mission System Architecture Platform (MSAP) represents an effort to bolster efficiency in the spacecraft design process. By incorporating essential spacecraft functionality into a modular, expandable system, the MSAP provides a foundation on which future spacecraft missions can be developed. Once completed, the MSAP will provide support for missions with varying objectives, while maintaining a level of standardization that will minimize redesign of general system components. One subsystem of the MSAP, the Remote Engineering Unit (REU), functions by gathering engineering telemetry from strategic points on the spacecraft and providing these measurements to the spacecraft's Command and Data Handling (C&DH) subsystem. Before the MSAP Project reaches completion, all hardware, including the REU, must be verified. However, the speed and complexity of the REU circuitry rules out the possibility of physical prototyping. Instead, the MSAP hardware is designed and verified using the Verilog Hardware Definition Language (HDL). An increasingly popular means of digital design, HDL programming provides a level of abstraction, which allows the designer to focus on functionality while logic synthesis tools take care of gate-level design and optimization. As verification of the REU proceeds, errors are quickly remedied, preventing costly changes during hardware validation. After undergoing the careful, iterative processes of verification and validation, the REU and MSAP will prove their readiness for use in a multitude of spacecraft missions.

  18. A Single-Unit Design Structure and Gender Differences in the Swimming World Championships

    OpenAIRE

    2014-01-01

    Four 50 meter male/female finals - the freestyle, butterfly, breaststroke, and backstroke - swum during individual events at the Swimming World Championships (SWCs) can be defined in four clusters. The aim of the present study was to use a single-unit design structure, in which the swimmer was defined at only one scale, to evaluate gender differences in start reaction times among elite swimmers in 50 m events. The top six male and female swimmers in the finals of four swimming stroke final ev...

  19. Uniting individual and collective concerns through design: Priming across the senses

    DEFF Research Database (Denmark)

    Cash, Philip; Holm-Hansen, Christopher; Olsen, Sebastian Borum

    2017-01-01

    This paper contributes to design for behaviour change by testing the potential of priming via everyday products as a means of influencing users and dissolving conflicting individual and collective concerns. Self-construal is introduced as a core explanatory concept with respect to behaviours...... that unite individual and collective concerns. Two studies are reported. In the first, abstract representations of the target behaviour are elicited and incorporated into subconscious priming stimuli for each of the major senses: sight, hearing, touch, and smell. These primes are then evaluated...... in a controlled experiment. From these studies implications for both researchers and practitioners are identified. In particular, priming showed a significant effect across all senses....

  20. Design of the Laboratory-Scale Plutonium Oxide Processing Unit in the Radiochemical Processing Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Lumetta, Gregg J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Meier, David E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tingey, Joel M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Casella, Amanda J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Delegard, Calvin H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Edwards, Matthew K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Orton, Robert D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rapko, Brian M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Smart, John E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-05-01

    This report describes a design for a laboratory-scale capability to produce plutonium oxide (PuO2) for use in identifying and validating nuclear forensics signatures associated with plutonium production, as well as for use as exercise and reference materials. This capability will be located in the Radiochemical Processing Laboratory at the Pacific Northwest National Laboratory. The key unit operations are described, including PuO2 dissolution, purification of the Pu by ion exchange, precipitation, and re-conversion to PuO2 by calcination.

  1. Design of area and power efficient Radix-4 DIT FFT butterfly unit using floating point fused arithmetic

    Institute of Scientific and Technical Information of China (English)

    Prabhu E; Mangalam H; Karthick S

    2016-01-01

    In this work, power efficient butterfly unit based FFT architecture is presented. The butterfly unit is designed using floating-point fused arithmetic units. The fused arithmetic units include two-term dot product unit and add-subtract unit. In these arithmetic units, operations are performed over complex data values. A modified fused floating-point two-term dot product and an enhanced model for the Radix-4 FFT butterfly unit are proposed. The modified fused two-term dot product is designed using Radix-16 booth multiplier. Radix-16 booth multiplier will reduce the switching activities compared to Radix-8 booth multiplier in existing system and also will reduce the area required. The proposed architecture is implemented efficiently for Radix-4 decimation in time (DIT) FFT butterfly with the two floating-point fused arithmetic units. The proposed enhanced architecture is synthesized, implemented, placed and routed on a FPGA device using Xilinx ISE tool. It is observed that the Radix-4 DIT fused floating-point FFT butterfly requires 50.17% less space and 12.16% reduced power compared to the existing methods and the proposed enhanced model requires 49.82% less space on the FPGA device compared to the proposed design. Also, reduced power consumption is addressed by utilizing the reusability technique, which results in 11.42% of power reduction of the enhanced model compared to the proposed design.

  2. Clinical analysis of continuous blood filtration combined with naloxone in treatment of PICU multiple organ dysfunction syndrome%连续性血液滤过联合纳洛酮治疗PICU多器官功能障碍综合征的临床分析

    Institute of Scientific and Technical Information of China (English)

    杨房; 翟波; 金志鹏

    2015-01-01

    目的:探讨连续性血液滤过联合纳洛酮治疗儿科重症监护病房( pediatric intensive care unit ,PICU)多器官功能障碍综合征( multiple organ dysfunction syndrome ,MODS)的治疗效果及应用价值。方法选择郑州市儿童医院治疗的多器官功能障碍综合征患者42例作为研究对象,采取随机数字表法分为观察组和对照组,每组各21例,对照组采用PICH常规治疗,观察组在对照组基础上联合连续性血液滤过和纳洛酮治疗,比较2组患者生命体征、肌酐、肌酸激酶及天冬氨酸转氨酶水平以及住院时间与血液滤过使用时间。结果观察组患者治疗后1d和治疗后3d在心率、氧合指数、肌酐、肌酸激酶以及天冬氨酸转氨酶各项指标改善情况均优于对照组同一时间节点(P<0.05)。观察组连续性血液滤过使用时间和住院时间均短于对照组(P<0.05)。结论采用连续性血液滤过联合纳洛酮治疗PICU中MODS疗效可靠,明显改善患者肾脏功能,缩短患者住院时间,清除患者血浆中的炎症介质因子。%Objective To investigate clinical effect of patients with PICU multiple organ dysfunction by continuous blood filtration combined with naloxone.Methods 42 patients with multiple organ function failure were selected and randomly divided into 2 groups.The control group were treated by PICU conventional therapy, the experiment group were treated by continuous blood filtration combined with Naloxone.Vital signs, creatinine, creatine kinase and aspartate aminotransferase levels, length of stay and blood filtration were compared after 1 day and 3 days treatment.ResuIts Compared with control group,heart rate, oxidation index,creatinine and aspartate aminotransferase levels of the experiment group were lower(P<0.05).After 1 day and 3 days, compared with cnontrol group, length of stay and blood filtration of the experiment were lower(P<0.05).Conc

  3. Computational and Pharmacological Target of Neurovascular Unit for Drug Design and Delivery

    Directory of Open Access Journals (Sweden)

    Md. Mirazul Islam

    2015-01-01

    Full Text Available The blood-brain barrier (BBB is a dynamic and highly selective permeable interface between central nervous system (CNS and periphery that regulates the brain homeostasis. Increasing evidences of neurological disorders and restricted drug delivery process in brain make BBB as special target for further study. At present, neurovascular unit (NVU is a great interest and highlighted topic of pharmaceutical companies for CNS drug design and delivery approaches. Some recent advancement of pharmacology and computational biology makes it convenient to develop drugs within limited time and affordable cost. In this review, we briefly introduce current understanding of the NVU, including molecular and cellular composition, physiology, and regulatory function. We also discuss the recent technology and interaction of pharmacogenomics and bioinformatics for drug design and step towards personalized medicine. Additionally, we develop gene network due to understand NVU associated transporter proteins interactions that might be effective for understanding aetiology of neurological disorders and new target base protective therapies development and delivery.

  4. Towards the formal verification of the requirements and design of a processor interface unit: HOL listings

    Science.gov (United States)

    Fura, David A.; Windley, Phillip J.; Cohen, Gerald C.

    1993-01-01

    This technical report contains the Higher-Order Logic (HOL) listings of the partial verification of the requirements and design for a commercially developed processor interface unit (PIU). The PIU is an interface chip performing memory interface, bus interface, and additional support services for a commercial microprocessor within a fault tolerant computer system. This system, the Fault Tolerant Embedded Processor (FTEP), is targeted towards applications in avionics and space requiring extremely high levels of mission reliability, extended maintenance-free operation, or both. This report contains the actual HOL listings of the PIU verification as it currently exists. Section two of this report contains general-purpose HOL theories and definitions that support the PIU verification. These include arithmetic theories dealing with inequalities and associativity, and a collection of tactics used in the PIU proofs. Section three contains the HOL listings for the completed PIU design verification. Section 4 contains the HOL listings for the partial requirements verification of the P-Port.

  5. Designing User Interfaces for Smart-Applications for Operating Rooms and Intensive Care Units

    Science.gov (United States)

    Kindsmüller, Martin Christof; Haar, Maral; Schulz, Hannes; Herczeg, Michael

    Today’s physicians and nurses working in operating rooms and intensive care units have to deal with an ever increasing amount of data. More and more medical devices are delivering information, which has to be perceived and interpreted in regard to patient status and the necessity to adjust therapy. The combination of high information load and insufficient usability creates a severe challenge for the health personnel with respect to proper monitoring of these devices respective to acknowledging alarms and timely reaction to critical incidents. Smart Applications are a new kind of decision support systems that incorporate medical expertise in order to help health personnel in regard to diagnosis and therapy. By means of a User Centered Design process of two Smart Applications (anaesthesia monitor display, diagnosis display), we illustrate which approach should be followed and which processes and methods have been successfully applied in fostering the design of usable medical devices.

  6. Numerical design of the Seed-Blanket Unit for the thorium nuclear fuel cycle

    Directory of Open Access Journals (Sweden)

    Oettingen Mikołaj

    2016-01-01

    Full Text Available In the paper we present the Monte Carlo modelling by the means of the Monte Carlo Continuous Energy Burn-up Code of the 17x17 Pressurized Water Reactor fuel assembly designed according to the Radkowsky Thorium Fuel concept. The design incorporates the UO2 seed fuel located in the centre and (Th,UO2 blanket fuel located in the peripheries of fuel assembly. The high power seed region supplies neutrons for the low power blanket region and thus induces breeding of fissile 233U from fertile 232Th. The both regions are physically separated and thus this approach is also known as either the heterogonous approach or the Seed-Blanket Unit. In the numerical analysis we consider the time evolutions of infinite neutron multiplication factor, axial/radial power density profile, 233U, 235U and 232Th.

  7. Major design issues of molten carbonate fuel cell power generation unit

    Energy Technology Data Exchange (ETDEWEB)

    Chen, T.P.

    1996-04-01

    In addition to the stack, a fuel cell power generation unit requires fuel desulfurization and reforming, fuel and oxidant preheating, process heat removal, waste heat recovery, steam generation, oxidant supply, power conditioning, water supply and treatment, purge gas supply, instrument air supply, and system control. These support facilities add considerable cost and system complexity. Bechtel, as a system integrator of M-C Power`s molten carbonate fuel cell development team, has spent substantial effort to simplify and minimize these supporting facilities to meet cost and reliability goals for commercialization. Similiar to other fuels cells, MCFC faces design challenge of how to comply with codes and standards, achieve high efficiency and part load performance, and meanwhile minimize utility requirements, weight, plot area, and cost. However, MCFC has several unique design issues due to its high operating temperature, use of molten electrolyte, and the requirement of CO2 recycle.

  8. A simplified propeller turbine runner design for stand alone micro-hydro power generation units

    Energy Technology Data Exchange (ETDEWEB)

    Demetriades, G.M.; Williams, A.A.; Smith, N.P.A. [Nottingham Trent University (United Kingdom). Micro-Hydro Research Group

    1996-07-01

    In most developing countries, the vast majority of potential micro-hydro power generation sites, i.e. with power outputs up to 100 kW, are found in areas with high rainfall or extensive irrigation works with small canal drops. These sites, where the available head does not exceed 5 m, are usually referred to as low head sites. The present paper introduces a simplified design of a propeller turbine suitable for direct coupling to an induction generator. The use of such a unit is a promising technology for setting up low-head power generation schemes for village electrification in developing countries. Emphasis is given to the hydraulic design of the runner blades which are made of constant thickness sheets of metal. The use of such a shape is ideal for low cost manufacturing in developing countries as it enables local skills and materials to be used. (author)

  9. Renewable energy policy design and framing influence public support in the United States

    Science.gov (United States)

    Stokes, Leah C.; Warshaw, Christopher

    2017-08-01

    The United States has often led the world in supporting renewable energy technologies at both the state and federal level. However, since 2011 several states have weakened their renewable energy policies. Public opinion will probably be crucial for determining whether states expand or contract their renewable energy policies in the future. Here we show that a majority of the public in most states supports renewable portfolio standards, which require a portion of the electricity mix to come from renewables. However, policy design and framing can strongly influence public support. Using a survey experiment, we show that effects of renewable portfolio standards bills on residential electricity costs, jobs and pollution, as well as bipartisan elite support, are all important drivers of public support. In many states, these bills' design and framing can push public opinion above or below majority support.

  10. Computational and Pharmacological Target of Neurovascular Unit for Drug Design and Delivery.

    Science.gov (United States)

    Islam, Md Mirazul; Mohamed, Zahurin

    2015-01-01

    The blood-brain barrier (BBB) is a dynamic and highly selective permeable interface between central nervous system (CNS) and periphery that regulates the brain homeostasis. Increasing evidences of neurological disorders and restricted drug delivery process in brain make BBB as special target for further study. At present, neurovascular unit (NVU) is a great interest and highlighted topic of pharmaceutical companies for CNS drug design and delivery approaches. Some recent advancement of pharmacology and computational biology makes it convenient to develop drugs within limited time and affordable cost. In this review, we briefly introduce current understanding of the NVU, including molecular and cellular composition, physiology, and regulatory function. We also discuss the recent technology and interaction of pharmacogenomics and bioinformatics for drug design and step towards personalized medicine. Additionally, we develop gene network due to understand NVU associated transporter proteins interactions that might be effective for understanding aetiology of neurological disorders and new target base protective therapies development and delivery.

  11. Design, fabrication, and performance of foil journal bearing for the brayton rotating unit

    Science.gov (United States)

    Licht, L.; Branger, M.

    1973-01-01

    Foil bearings were designed and manufactured to replace pivoted-shoe journal bearings in an existing Brayton Cycle turbo-alternator-compressor. The design of this unconventional rotor support was accomplished within the constraints and space limitations imposed by the present machine, and the substitution of foil bearings was effected without changes or modification other machine components. A housing and a test rig were constructed to incorporate the new foil-bearing support into a unified assemble with an air-driven rotor and the gimbal-mounted thrust bearing, seals, and shrouds of an actual Brayton Rotating Unit. The foil bearing required no external pressure source, and stable self-acting rotation was achieved at all speeds up to 43,200 rpm. Excellent wipe-wear characteristics of the foil bearing permitted well over 1000 start-stop cycles with no deterioriation of performance in the entire speed range.

  12. Theoretical Design of High-spin Organic Molecules with Heterocycles as Ferromagnetic Coupling Units

    Institute of Scientific and Technical Information of China (English)

    WANG Li-min; ZHANG Jing-ping; WANG Rong-shun

    2003-01-01

    Novel stable high spin molecules possessing three different arranged fashions are designed with -*N-N< as a spin-containing(SC) fragment, phenylene as an end group and various aromatic molecules, such as benzene(1), 2,6-pyridine(2), 3,5-pyridine(3), pyridazine(4), 4,6-pyrimidine(5), 2,6-pyrimidine(6), pyrazine(7) and triazine(8), as a ferromagnetic coupling(FC) unit. The effects of the different coupling units on the spin multiplicities of the ground states and their stabilities were investigated by means of AM1-CI approach. It has been found that the spin densities on the two atoms of the SC fragment are different from delocalization results in the specific stability of -*N-N<. In these molecules, the stabilities of the triplet states decrease when the distance between the atoms of central SC(-N-) increases. It is shown that the heterocycles as the coupling units have influence on the stabilities of the high-spin ground states. That the heteroatom lying in m-phenyl can improve ferromagnetic coupling, while the heteroatom lying in o-phenyl or p-phenyl is not in favor of the ferromagnetic coupling.

  13. Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery.

    Science.gov (United States)

    De Falco, Iris; Gerboni, Giada; Cianchetti, Matteo; Menciassi, Arianna

    2015-11-14

    In recent years, soft robotics technologies have aroused increasing interest in the medical field due to their intrinsically safe interaction in unstructured environments. At the same time, new procedures and techniques have been developed to reduce the invasiveness of surgical operations. Minimally Invasive Surgery (MIS) has been successfully employed for abdominal interventions, however standard MIS procedures are mainly based on rigid or semi-rigid tools that limit the dexterity of the clinician. This paper presents a soft and high dexterous manipulator for MIS. The manipulator was inspired by the biological capabilities of the octopus arm, and is designed with a modular approach. Each module presents the same functional characteristics, thus achieving high dexterity and versatility when more modules are integrated. The paper details the design, fabrication process and the materials necessary for the development of a single unit, which is fabricated by casting silicone inside specific molds. The result consists in an elastomeric cylinder including three flexible pneumatic actuators that enable elongation and omni-directional bending of the unit. An external braided sheath improves the motion of the module. In the center of each module a granular jamming-based mechanism varies the stiffness of the structure during the tasks. Tests demonstrate that the module is able to bend up to 120° and to elongate up to 66% of the initial length. The module generates a maximum force of 47 N, and its stiffness can increase up to 36%.

  14. Accelerated multidimensional radiofrequency pulse design for parallel transmission using concurrent computation on multiple graphics processing units.

    Science.gov (United States)

    Deng, Weiran; Yang, Cungeng; Stenger, V Andrew

    2011-02-01

    Multidimensional radiofrequency (RF) pulses are of current interest because of their promise for improving high-field imaging and for optimizing parallel transmission methods. One major drawback is that the computation time of numerically designed multidimensional RF pulses increases rapidly with their resolution and number of transmitters. This is critical because the construction of multidimensional RF pulses often needs to be in real time. The use of graphics processing units for computations is a recent approach for accelerating image reconstruction applications. We propose the use of graphics processing units for the design of multidimensional RF pulses including the utilization of parallel transmitters. Using a desktop computer with four NVIDIA Tesla C1060 computing processors, we found acceleration factors on the order of 20 for standard eight-transmitter two-dimensional spiral RF pulses with a 64 × 64 excitation resolution and a 10-μsec dwell time. We also show that even greater acceleration factors can be achieved for more complex RF pulses. Copyright © 2010 Wiley-Liss, Inc.

  15. RCGVS design improvement and depressurization capability tests for Ulchin nuclear power plant units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Kang Sik; Seong, Ho Je; Jeong, Won Sang; Seo, Jong Tae; Lee, Sang Keun [Korea Power Engineering Company, Inc., Seoul (Korea, Republic of); Lim, Keun Hyo; Choi, Kwon Sik; Oh, Chul Sung [Korea Electric Power Cooperation, Taejon (Korea, Republic of)

    1998-12-31

    The Reactor Coolant Gas Vent System(RCGVS) design for Ulchin Nuclear Power Plant Units 3 and 4 (UCN 3 and 4) has been improved from the Yonggwang Nuclear Power Plant Units 3 and 4 (YGN 3 and 4) based on the evaluation results for depressurization capability tests performed at YGN 3 and 4. There has been a series of plant safety analyses for Natural Circulation Cooldown(NCC) event and thermo-dynamic analyses with RELAP5 code for the steam blowdown phenomena in order to optimize the orifice size of UCN 3 and 4 RCGVS. Based on these analyses results, the RCGVS orifics size for UCN 3 and 4 has been reduced to 9/32 inch from the 11/32 inch for YGN 3 and 4. The depressurization capability tests, which were performed at UCN 3 in order to verify the FSAR NCC analysis results, show that the RCGVS depressurization rates are being within the acceptable ranges. Therefore, it is concluded that the orificed flow path of UCN 3 and 4 RCGVS is adequately designed, and can provide the safety-grade depressurization capability required for a safe plant operation. 6 refs., 5 figs., 1 tab. (Author)

  16. Research on an Intelligent Decision Support System for a Conceptual Innovation Design of Pumping Units Based on TRIZ

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Attention is concentrated on how to perform the innovative design during the process of pumping unit conceptual design, and how to enhance design efficiency and inspire creativity. Aiming at the shortages of conceptual design, introducing the theory of inventive problem solving (TRIZ) into the mechanical product design for producing innovative ideas, and using the advanced computer-aided technique, the intelligent decision support system (IDSS) based on TRIZ (TRIZ-IDSS) has been constructed. The construction method, system structure, conceptual production, decision-making and evaluation of the problem solving subsystem are discussed. The innovative conceptual design of pumping units indicates that the system can help the engineers open up a new space of thinking, overcome the thinking inertia, and put forward innovative design concepts. This system also can offer the scientific instructions for the innovative design of mechanical products.

  17. Ecological relevance of current water quality assessment unit designations in impaired rivers

    Science.gov (United States)

    Layhee, Megan J.; Sepulveda, Adam; Ray, Andrew; Mladenka, Greg; Van Every, Lynn

    2016-01-01

    Managers often nest sections of water bodies together into assessment units (AUs) to monitor and assess water quality criteria. Ideally, AUs represent an extent of waters with similar ecological, watershed, habitat and land-use conditions and no overlapping characteristics with other waters. In the United States, AUs are typically based on political or hydrologic boundaries rather than on ecologically relevant features, so it can be difficult to detect changes in impairment status. Our goals were to evaluate if current AU designation criteria of an impaired water body in southeastern Idaho, USA that, like many U.S. waters, has three-quarters of its mainstem length divided into two AUs. We focused our evaluation in southeastern Idaho's Portneuf River, an impaired river and three-quarters of the river is divided into two AUs. We described biological and environmental conditions at multiple reaches within each AU. We used these data to (1) test if variability at the reach-scale is greater within or among AUs and, (2) to evaluate alternate AU boundaries based on multivariate analyses of reach-scale data. We found that some biological conditions had greater variability within an AU than between AUs. Multivariate analyses identified alternative, 2- and 3-group, AUs that reduced this variability. Our results suggest that the current AU designations in the mainstem Portneuf River contain ecologically distinct sections of river and that the existing AU boundaries should be reconsidered in light of the ecological conditions measured at the reach scale. Variation in biological integrity within designated AUs may complicate water quality and biological assessments, influence management decisions or affect where monitoring or mitigation resources are directed.

  18. An Efficient Micro Control Unit with a Reconfigurable Filter Design for Wireless Body Sensor Networks (WBSNs

    Directory of Open Access Journals (Sweden)

    Chiung-An Chen

    2012-11-01

    Full Text Available In this paper, a low-cost, low-power and high performance micro control unit (MCU core is proposed for wireless body sensor networks (WBSNs. It consists of an asynchronous interface, a register bank, a reconfigurable filter, a slop-feature forecast, a lossless data encoder, an error correct coding (ECC encoder, a UART interface, a power management (PWM, and a multi-sensor controller. To improve the system performance and expansion abilities, the asynchronous interface is added for handling signal exchanges between different clock domains. To eliminate the noise of various bio-signals, the reconfigurable filter is created to provide the functions of average, binomial and sharpen filters. The slop-feature forecast and the lossless data encoder is proposed to reduce the data of various biomedical signals for transmission. Furthermore, the ECC encoder is added to improve the reliability for the wireless transmission and the UART interface is employed the proposed design to be compatible with wireless devices. For long-term healthcare monitoring application, a power management technique is developed for reducing the power consumption of the WBSN system. In addition, the proposed design can be operated with four different bio-sensors simultaneously. The proposed design was successfully tested with a FPGA verification board. The VLSI architecture of this work contains 7.67-K gate counts and consumes the power of 5.8 mW or 1.9 mW at 100 MHz or 133 MHz processing rate using a TSMC 0.18 μm or 0.13 μm CMOS process. Compared with previous techniques, this design achieves higher performance, more functions, more flexibility and higher compatibility than other micro controller designs.

  19. Final design of the Switching Network Units for the JT-60SA Central Solenoid

    Energy Technology Data Exchange (ETDEWEB)

    Lampasi, Alessandro, E-mail: alessandro.lampasi@enea.it [National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Frascati (Italy); Coletti, Alberto; Novello, Luca [Fusion for Energy (F4E) Broader Fusion Development Department, Garching (Germany); Matsukawa, Makoto [Japan Atomic Energy Agency, Naka Fusion Institute, Mukouyama, Naka-si, Ibaraki-ken (Japan); Burini, Filippo; Taddia, Giuseppe; Tenconi, Sandro [OCEM Energy Technology, San Giorgio Di Piano (Italy)

    2014-04-15

    This paper describes the approved detailed design of the four Switching Network Units (SNUs) of the superconducting Central Solenoid of JT-60SA, the satellite tokamak that will be built in Naka, Japan, in the framework of the “Broader Approach” cooperation agreement between Europe and Japan. The SNUs can interrupt a current of 20 kA DC in less than 1 ms in order to produce a voltage of 5 kV. Such performance is obtained by inserting an electronic static circuit breaker in parallel to an electromechanical contactor and by matching and coordinating their operations. Any undesired transient overvoltage is limited by an advanced snubber circuit optimized for this application. The SNU resistance values can be adapted to the specific operation scenario. In particular, after successful plasma breakdown, the SNU resistance can be reduced by a making switch. The design choices of the main SNU elements are justified by showing and discussing the performed calculations and simulations. In most cases, the developed design is expected to exceed the performances required by the JT-60SA project.

  20. Theoretical design of high-spin biradical molecules with heterocycles as coupling unit

    Institute of Scientific and Technical Information of China (English)

    WANG Li-min; CHU De-qing; ZHANG Jing-ping; WANG Rong-shun

    2006-01-01

    Computational studies of a class of potentially stable high-spin biradicals that two-atom-three-electron spin centers SC units connected by heterocycles FC and phenyl EG were described. The geometry and character of the spin exchange interaction were obtained by means of UB3LYP/6-31G*. The results show that the molecules possessing three different arranged fashions are designed with—·N—S as SC fragment,pyridine as FC and phenyl as EG,the spin densities on the two atoms of the SC fragment are different from the delocalization results in the specific stability of—·N—S. In these molecules,the stabilities of the triplet states decrease when the distance between the atoms of central SC (—N—) increases. Molecules with—·N—S as SC fragment,pyridine,pyrazine and triazine as FC and phenyl as EG are designed,the stability of triplet states for the molecule with pyridine as FC is the highest,and that for the molecule with pyrazine as FC is the lowest. Molecules with—·N—S,— ··N—O and—·N—NH as SC fragment,pyridine as FC and phenyl as EG are designed,the stability of triplet states for the molecule with—·N—S as SC is the highest,that for the molecule with—·N—NH as SC is the lowest.

  1. Design and Testing of a Breadboard Electrical Power Control Unit for the Fluid Combustion Facility Experiment

    Science.gov (United States)

    Kimnach, Greg L.; Lebron, Ramon C.

    1999-01-01

    The Fluid Combustion Facility (FCF) Project and the Power Technology Division at the NASA Glenn Research Center (GRC) at Lewis Field in Cleveland, OH along with the Sundstrand Corporation in Rockford, IL are jointly developing an Electrical Power Converter Unit (EPCU) for the Fluid Combustion Facility to be flown on the International Space Station (ISS). The FCF facility experiment contains three racks: A core rack, a combustion rack, and a fluids rack. The EPCU will be used as the power interface to the ISS 120V(sub dc) power distribution system by each FCF experiment rack which requires 28V(sub dc). The EPCU is a modular design which contains three 120V(sub dc)-to-28V(sub dc) full-bridge, power converters rated at 1 kW(sub e) each bus transferring input relays and solid-state, current-limiting input switches, 48 current-limiting, solid-state, output switches; and control and telemetry hardware. The EPCU has all controls required to autonomously share load demand between the power feeds and--if absolutely necessary--shed loads. The EPCU, which maximizes the usage of allocated ISS power and minimizes loss of power to loads, can be paralleled with other EPCUs. This paper overviews the electrical design and operating characteristics of the EPCU and presents test data from the breadboard design.

  2. Liquid Acquisition Device Hydrogen Outflow Testing on the Cryogenic Propellant Storage and Transfer Engineering Design Unit

    Science.gov (United States)

    Zimmerli, Greg; Statham, Geoff; Garces, Rachel; Cartagena, Will

    2015-01-01

    As part of the NASA Cryogenic Propellant Storage and Transfer (CPST) Engineering Design Unit (EDU) testing with liquid hydrogen, screen-channel liquid acquisition devices (LADs) were tested during liquid hydrogen outflow from the EDU tank. A stainless steel screen mesh (325x2300 Dutch T will weave) was welded to a rectangular cross-section channel to form the basic LAD channel. Three LAD channels were tested, each having unique variations in the basic design. The LADs fed a common outflow sump at the aft end of the 151 cu. ft. volume aluminum tank, and included a curved section along the aft end and a straight section along the barrel section of the tank. Wet-dry sensors were mounted inside the LAD channels to detect when vapor was ingested into the LADs during outflow. The use of warm helium pressurant during liquid hydrogen outflow, supplied through a diffuser at the top of the tank, always led to early breakdown of the liquid column. When the tank was pressurized through an aft diffuser, resulting in cold helium in the ullage, LAD column hold-times as long as 60 minutes were achieved, which was the longest duration tested. The highest liquid column height at breakdown was 58 cm, which is 23 less than the isothermal bubble-point model value of 75 cm. This paper discusses details of the design, construction, operation and analysis of LAD test data from the CPST EDU liquid hydrogen test.

  3. Stair design in the United States and obesity: the need for a change.

    Science.gov (United States)

    Mansi, Ishak A; Mansi, Nardine; Shaker, Hayam; Banks, Daniel

    2009-06-01

    Maintenance of healthy body weight is a function of total energy expenditure including household and workplace activity. Light to moderate physical activity has been found to be effective in motivating sedentary and obese individuals, and is at least as effective as structured exercise in lowering weight in some studies. Stair use offers a promising intervention for increasing physical activity, because it involves a lifestyle choice that must be made (people must get to their destination), and it requires no personal financial cost. Stairs in United States buildings are frequently hidden from entrances with small signs denoting their location, mainly in connection to fire exits. Using the stairs is usually seen as a way of escaping from fires rather than as a recommended daily activity. To comply with State Fire Marshal regulations, stairs are usually guarded by heavy, spring doors, without air conditioning, and are noncarpeted. In this article, several suggestions to change the architectural design in buildings to be more physical activity-friendly are discussed. Such changes would make stairs attractive, safe, and readily accessible. Local and state authorities may also allow incentives for such designs to compensate for their additional costs. Moreover, standard national building codes that incorporate health concerns should be devised. Stair use at work and in living places has the potential to increase physical activity and decrease obesity. Changing stair design to encourage their use requires a series of interventions both architecturally and legislatively to create physical environments that support active lifestyles.

  4. 儿童重症监护病房医院感染危险因素评价及控制对策%Risk factors of nosocomial infection in PICU evaluation and control measures

    Institute of Scientific and Technical Information of China (English)

    曾苹; 张国英

    2012-01-01

    Objectives To evaluate risk factors for nosocomial infection in a PICU in order to facilitate early recognition and formulate preventive measures. Methods The combined method of prospective monitoring and retrospective study were used in the present study. Risk factors of recruited cases were statistically analyzed. Results By univariant study, 12 factors were associated with nosocomial infection. After multi-variant logistic regression analysis, 5 risk factors were associated with nosocomial infection including pediatric critical illness score (PCIS), age (7 days), endotracheal intubation for mechanical ventilation and total parenteral nutrition (TPN). Conclusion Risk factors for nosocomial infection in PICU can be evaluated and classified to form basis of an early warning score. This will help patient management in PICU and encourage protective isolation for high risk patients. Other effective preventive measures against nosocomial infection include minimizing invasive procedures, judicious use of antibiotics and strict aseptic technique.%目的 探讨儿童重症监护病房(PICU)医院感染危险因素的评价指标,以利于早期认识和诊断,从而建立有效的预防对策.方法 用前瞻性监测和回顾性调查相结合的方法,将入选病例的危险因素进行分类分项研究,分析其与医院感染发生的相关性.进行危险因素统计学分析.结果 指标中单因素分析共有12项与医院感染发生相关,对其进行多元Logistic回归分析,最后纳入的相关指标为国内小儿危重病例评分(PCIS)、年龄(≤1岁)、入住PICU时间(>7天)、气管插管/机械通气、肠外营养等5项.结论 医院感染危险因素分类建立评价指标,为建立医院感染预警提供依据.加强PICU病房管理,加强危重患儿的保护性隔离,减少有创性操作,合理使用抗生素,严格无菌操作等均是预防PICU医院感染的有效措施.

  5. Design and accomplishment for the monitoring unit of the sup 6 sup 0 Co train freight inspection system

    CERN Document Server

    Cong Peng

    2002-01-01

    The sup 6 sup 0 Co railway cargo inspection system has super automaticity. And the monitoring unit is an important part of the automatic control system. The author introduces the idea of designing the monitoring unit in detail and accomplishes a new-style unit which is different from the traditional one. The monitoring unit which is highly integrated, easy to be mounted and debugged and convenient to be operated and maintained has play an excellent role in the work of the whole inspection system

  6. Facilitating resident information seeking regarding meals in a special care unit: an environmental design intervention.

    Science.gov (United States)

    Nolan, Beth A D; Mathews, R Mark

    2004-10-01

    Repetitive questions and requests for information are common in older adults with dementia. The purpose of this environmental design intervention was to provide residents continuous access to information about common mealtime questions with the intent of decreasing agitation around mealtimes and facilitating more pleasant patient-staff and patient-patient interactions. A special care unit for residents with dementia of the Alzheimer's type was the setting. During the intervention conditions, a large clock and a sign with large lettering that identified mealtimes were hung in the dining area. Direct observations of 35 residents were conducted at mealtimes for a 5-month period. Results showed reductions from baseline to the intervention phase in food-related questions or requests. These results suggest a simple, inexpensive environmental change intervention can reduce repetitive questions commonly exhibited by individuals with dementia.

  7. Design of RF energy harvesting platforms for power management unit with start-up circuits

    Science.gov (United States)

    Costanzo, Alessandra; Masotti, Diego

    2013-12-01

    In this contribution we discuss an unconventional rectifier design dedicated to RF energy harvesting from ultra-low sources, such as ambient RF sources which are typically of the order of few to few tens of μW. In such conditions unsuccessful results may occur if the rectenna is directly connected to its actual load since either the minimum power or the minimum activation voltage may not be simultaneously available. For this reason a double-branch rectifier topology is considered for the power management unit (PMU), instead of traditional single-branch one. The new PMU, interposed between the rectenna and application circuits, allows the system to operate with significantly lower input power with respect to the traditional solution, while preserving efficiency during steady-state power conversion.

  8. Ultrasonic inspection technology development and search units design examples of practical applications

    CERN Document Server

    Brook, Mark V

    2012-01-01

    "Ultrasonic testing is a relatively new branch of science and industry. The development of ultrasonic testing started in the late 1920s. At the beginning, the fundamentals of this method were borrowed from basic physics, geometrical and wave optics, acoustics and seismology. Later it became clear that some of these theories and calculation methods could not always explain the phenomena observed in many specific cases of ultrasonic testing. Without knowing the nuances of the ultrasonic wave propagation in the test object it is impossible to design effective inspection technique and search units for it realization. This book clarifies the theoretical differences of ultrasonics from the other wave propagation theories presenting both basics of physics in the wave propagation, elementary mathematic and advanced practical applications. Almost every specific technique presented in this book is proofed by actual experimental data and examples of calculations"--

  9. Nuclear design report for Ulchin nuclear power plant unit 1, cycle 7

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Rae; Park, Yong soo [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-04-01

    This report presents nuclear design calculations for Cycle 7 of Ulchin Unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 56 KOFA`s enriched by nominally 4.00 w/o U{sub 235}. Among the KOFA`s 36 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of Cycle 7 amounts to 355 EFPD corresponding to a cycle burnup of 14280 MWD/MTU. (Author) 8 refs., 55 figs., 21 tabs.

  10. Nuclear design report for Ulchin nuclear power plant unit 2 cycle 5

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ha; Park, Yong Soo; Cho, Byeong Ho; Zee, Sung Kyun; Lee, Sang Keun; Ahn, Dawk Hwan [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1993-09-01

    This report presents nuclear design calculations for cycle 5 of Ulchin unit it 2. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 48 KOFA`s enriched by nominally 3.50 w/o U{sub 235}. Among the KOFA`s, 20 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of cycle 5 amounts to 293 EFPD corresponding to a cycle burnup of 11780 MWD/MTU. (Author) 8 refs., 55 figs., 16 tabs.

  11. Nuclear design report for Yonggwang nuclear power plant unit 1 cycle 9

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young chul; Kim, Jae Hak; Song, Jae Woong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-03-01

    This report presents nuclear design calculations for Cycle 6 of Yonggwng Unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 76 KOFA`s enriched by nominally 4.00 w/o U{sub 235}. Among the KOFA`s, 60 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of Cycle 9 amounts to 434 EFPD corresponding to a cycle burnup of 17470 MWD/MTU. (Author) 8 refs., 55 figs., 19 tabs.

  12. Nuclear design report for Kori nuclear power plant unit 4 cycle 8

    Energy Technology Data Exchange (ETDEWEB)

    Zee, Sung Kyoon; Jung, Yil Sub; Kim, Si Yung [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1993-07-01

    This report presents nuclear design calculations for cycle 8 of Kori unit 4. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 76 KOFA`s enriched by nominally 3.70 w/o U{sub 235}. Among the KOFA`s 48 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of cycle 8 amounts to 421 EFPD corresponding to a cycle burnup of 16950 MWD/MTU. (Author) 8 refs., 55 figs., 17 tabs.

  13. Nuclear design report for Ulchin nuclear power plant unit 2, cycle 6

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Oh; Park, Jin Ha; Kim, Yong Rae; Park, Sang Yoon; Lee, Jong Chul; Baik, Joo Hyun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-08-01

    This report presents nuclear design calculations for cycle 6 of Ulchin unit 2. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 64 KOFA`s enriched by nominally 3.80 w/o U{sub 235}. Among the KOFA`s, 36 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of cycle 6 amounts to 388 EFPD corresponding to a cycle burnup of 15610 MWD/MTU. (Author) 8 refs., 55 figs., 17 tabs.

  14. Nuclear design report for Kori nuclear power plant unit 1, cycle 13

    Energy Technology Data Exchange (ETDEWEB)

    Zee, Sung Kyun; Moon, Bok Ja; Cho, Byeong Ho; Jung, Yil Sup [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1993-04-01

    This report presents nuclear design calculations for cycle 13 of Kori unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 44 KOFA`s enriched by nominally 3.70 w/o U{sub 235}. Among the KOFA`s, 16 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of cycle 13 amounts to 355 EFPD corresponding to a cycle burnup of 13240 MWD/MTU. (Author) 8 refs., 55 figs., 16 tabs.

  15. Nuclear design report for Yonggwang nuclear power plant unit 1, cycle 8

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Chul; Kim, Jae Hak; Park, Sang Yoon; Zee, Sung Kyun; Lee, Sang Keun; Ahn, Dawk Hwan [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1993-10-01

    This report presents nuclear design calculations for cycle 8 of Kori unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 76 KOFA`s enriched by nominally 3.70 w/o U{sub 235}. Among the KOFA`s, 56 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of cycle 8 amounts to 447 EFPD corresponding to a cycle burnup of 18020 MWD/MTU. (Author) 8 refs., 39 figs., 17 tabs.

  16. Nuclear design report for Ulchin nuclear power plant unit 1, cycle 6

    Energy Technology Data Exchange (ETDEWEB)

    Zee, Sung Kyun; Kim, Yong Rae; Park, Yong Soo; Cho, Byeong Ho; Lee, Sang Keun; Ahn, Dawk Hwan [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1993-12-01

    This report presents nuclear design calculations for cycle 6 of Ulchin unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 64 KOFA`s enriched by nominally 3.70 w/o U{sub 235}. Among the KOFA`s, 32 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of cycle 6 amounts to 369 EFPD corresponding to a cycle burnup of 14850 MWD/MTU. (Author) 8 refs., 55 figs., 17 tabs.

  17. Modeling and Implementation of Reliable Ternary Arithmetic and Logic Unit Design Using Vhdl

    Directory of Open Access Journals (Sweden)

    Meruva Kumar Raja

    2014-06-01

    Full Text Available Multivalve logic is a reliable method for defining, analyzing, testing and implementing the basic combinational circuitry with VHDL simulator. It offers better utilization of transmission channels because of its high speed for higher information carried out and it gives more efficient performance. One of the main realizing of the MVL (ternary logic is that reduces the number of required computation steps, simplicity and energy efficiency in digital logic design. This paper using reliable method is brought out for implementing the basic combinational, sequential and TALU (Ternary Arithmetic and Logic Unit circuitry with minimum number of ternary switching circuits (Multiplexers. In this the potential of VHDL modelling and simulation that can be applied to ternary switching circuits to verify its functionality and timing specifications. An intention is to show how proposed simulator can be used to simulate MVL circuits and to evaluate system performance.

  18. PORFLOW MODELING FOR A PRELIMINARY ASSESSMENT OF THE PERFORMANCE OF NEW SALTSTONE DISPOSAL UNIT DESIGNS

    Energy Technology Data Exchange (ETDEWEB)

    Smith, F.

    2012-08-06

    At the request of Savannah River Remediation (SRR), SRNL has analyzed the expected performance obtained from using seven 32 million gallon Saltstone Disposal Units (SDUs) in the Z-Area Saltstone Disposal Facility (SDF) to store future saltstone grout. The analysis was based on preliminary SDU final design specifications. The analysis used PORFLOW modeling to calculate the release of 20 radionuclides from an SDU and transport of the radionuclides and daughters through the vadose zone. Results from this vadose zone analysis were combined with previously calculated releases from existing saltstone vaults and FDCs and a second PORFLOW model run to calculate aquifer transport to assessment points located along a boundary 100 m from the nearest edge of the SDF sources. Peak concentrations within 12 sectors spaced along the 100 m boundary were determined over a period of evaluation extending 20,000 years after SDF closure cap placement. These peak concentrations were provided to SRR to use as input for dose calculations.

  19. Nuclear design report for Yonggwang nuclear power plant unit 1 cycle 9

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young chul; Kim, Jae Hak; Song, Jae Woong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-03-01

    This report presents nuclear design calculations for Cycle 6 of Yonggwng Unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 76 KOFA`s enriched by nominally 4.00 w/o U{sub 235}. Among the KOFA`s, 60 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of Cycle 9 amounts to 434 EFPD corresponding to a cycle burnup of 17470 MWD/MTU. (Author) 8 refs., 55 figs., 19 tabs.

  20. Design of an Integral Field Unit for MUSE, and Results from Prototyping

    Science.gov (United States)

    Laurent, Florence; Henault, Francois; Renault, Edgard; Bacon, Roland; Dubois, Jean-Pierre

    2006-11-01

    The research and development activity on image slicer systems for integral field spectroscopy has increased in recent years, allowing the simultaneous observation on the same detector matrix of two-dimensional sky maps and the spectral decomposition of light. Nowadays, image slicers lead to possible applications on future instrumentation for ground- and space-based telescopes, covering a spectral domain ranging from UV to mid-IR wavelengths. Among such projects, MUSE (Multi Unit Spectroscopic Explorer) is an integral field spectrograph proposed by the European Southern Observatory for its second-generation Very Large Telescope instrumentation. MUSE combines a 1'×1' field of view, with a spectral resolution reaching 3000 and a spatial sampling of 0.2" provided by an adaptive optics system. MUSE operates in the visible and near-IR wavelength range (0.465-0.93 μm) and is composed of 24 identical integral field units; each one incorporates an advanced image slicer made up of a combination of mirrors and ``minilens'' arrays, a spectrograph, and a detector. This paper describes the optical design of the MUSE image slicer, which complies with top-level requirements at a reasonable cost. The optical manufacturing technique, based on an original method of assembly using molecular adhesion, is presented. Finally, we focus on the optical tests of the prototype both at a system level and at the level of individual optical elements.

  1. Geographic variation, genetic structure and conservation unit designation in the larch mountain salamander( Plethodon larselli)

    Science.gov (United States)

    Wagner, R.S.; Miller, Mark P.; Crisafulli, Charles; Haig, Susan M.

    2005-01-01

    The Larch Mountain salamander (Plethodon larselli Burns, 1954) is an endemic species in the Pacific northwestern United States facing threats related to habitat destruction. To facilitate development of conservation strategies, we used DNA sequences and RAPDs (random amplified polymorphic DNA) to examine differences among populations of this species. Phylogenetic analyses of cytochrome b revealed a clade of haplotypes from populations north of the Columbia River derived from a clade containing haplotypes from the river's southwestern region. Haplotypes from southeastern populations formed a separate clade. Nucleotide diversity was reduced in northern populations relative to southern populations. These results were corroborated by analyses of RAPD loci, which revealed similar patterns of clustering and diversity. Network analyses suggested that northern populations were colonized following a range expansion mediated by individuals from populations located southwest of the river. Changes in the Columbia River's location during the Pliocene and Pleistocene likely released distributional constraints on this species, permitting their northern range expansion. Based on the barrier presented by the Columbia River's present location and differences in haplotype diversity and population structure observed between northern and southern populations, we suggest that designation of separate management units encompassing each region may assist with mitigating different threats to this species.

  2. Hydraulic design to optimize the treatment capacity of Multi-Stage Filtration units

    Science.gov (United States)

    Mushila, C. N.; Ochieng, G. M.; Otieno, F. A. O.; Shitote, S. M.; Sitters, C. W.

    2016-04-01

    Multi-Stage Filtration (MSF) can provide a robust treatment alternative for surface water sources of variable water quality in rural communities at low operation and maintenance costs. MSF is a combination of Slow Sand Filters (SSFs) and Pre-treatment systems. The general objective of this research was to optimize the treatment capacity of MSF. A pilot plant study was undertaken to meet this objective. The pilot plant was monitored for a continuous 98 days from commissioning till the end of the project. Three main stages of MSF namely: The Dynamic Gravel Filter (DGF), Horizontal-flow Roughing Filter (HRF) and SSF were identified, designed and built. The response of the respective MSF units in removal of selected parameters guiding drinking water quality such as microbiological (Faecal and Total coliform), Suspended Solids, Turbidity, PH, Temperature, Iron and Manganese was investigated. The benchmark was the Kenya Bureau (KEBS) and World Health Organization (WHO) Standards for drinking water quality. With respect to microbiological raw water quality improvement, MSF units achieved on average 98% Faecal and 96% Total coliform removal. Results obtained indicate that implementation of MSF in rural communities has the potential to increase access to portable water to the rural populace with a probable consequent decrease in waterborne diseases. With a reduced down time due to illness, more time would be spent in undertaking other economic activities.

  3. Experiences with self designed pyrolyses unit by utilization of various type of fuels

    Energy Technology Data Exchange (ETDEWEB)

    Juchelkova, Dagmar; Roubicek, Vaclav; Mikulova, Zuzana [VSB - Technische Univ. Ostrava (Czech Republic). Energieinst.; Smelik, Roman; Balco, Mario [Arrowline, a.s. (Czech Republic)

    2008-07-01

    According to the situation in the Czech Republic - existing only 3 municipal waste combustion units and about 50 small industrial waste incineration units it seems to be necessary to design some alternative for combustion process. Pyrolysis is an established process that can potentially be used to convert polymer-based materials of different types since a high yield in the separation is not necessary. Pyrolysis is the thermal degradation (without oxygen) led to produce a char, oil and gas. All of which have potential as useful end products. The Czech ministry of the environment seems to have bigger acceptance for the material recycling than for combustion processes. The concept pyrolyse is now to day understood as material recycling. Our work will be concern on the selected materials. Nowdays, polymer-based materials provide a fundamental contribution to all main daily activities (agriculture, automobile industry, packing and so on). Due to their excellent properties are now irreplaceable and absolutely necessary for people life. Their production and use are increasing sharply. On the other hand, they are not quickly decomposed and disposal of used plastics has become a serious problem. (orig.)

  4. PICU危重患儿呼吸道感染调查分析%Investigation of respiratory tract infections in PICU critically ill children

    Institute of Scientific and Technical Information of China (English)

    陈洋; 蔡小芳; 张隆; 贾德胜; 蓝莹

    2016-01-01

    OBJECTIVETo explore the respiratory tract infections in PICU children patients and to provide evidence for the treatment of respiratory tract infections in children .METHODSA total of 1000 cases of critically ill children treated in PICU from Jan .2011 to Dec .2014 in our hospital .According to children ages ,they were divided into two groups :≤6-month old group (n=538) and >6-month old group (n=462) .The incidence of respiratory tract infections in the two groups were compared ,and the distribution and drug resistance of pathogenic bacteria in children with respiratory tract infection were analyzed using VITEK‐AMS32 automatic bacterial identification , susceptibility analyzers ,matching identification card and Minka drug identification .Respiratory infections in chil‐dren and antibiotic resistance were analyzed . The results were statistically analyzed by software SPSS 17 .0 . RESULTSThere were 38 cases of respiratory tract infections in the 1000 cases of critically ill children with an infec‐tion rate of 3 .8% .The respiratory tract infection rate of patients in >6-month old group was 2 .2% which was significantly lower than that of ≤6-month old group with an infection rate of 5 .2% .The difference has statisti‐cal significance (P<0 .05) .A total of 45 strains of pathogenic bacteria were isolated from the infected children :25 strains of gram‐negative bacteria accounting for 55 .6% ,11 strains of gram‐positive bacteria accounting for 24 .4%and 9 strains of fungi and accounting for 20 .0% .Pathogenic bacteria mainly contained K lebsiellapneumoniae , Pseudomonas aeruginosa , Staphylococcus aureus and Candida albicans respectively accounting for 20 .0% , 13 .3% ,17 .8% and 15 .6% .Gram‐negative bacteria were more sensitive to commonly used antimicrobial drugs such as imipenem ,ciprofloxacin ,amikacin ,kanamycin ,gentamycin and levofloxacin .Staphylococcus aureus were more sensitive to linezolid and vancomycin . C .albicans were sensitive to

  5. Grout long radius flow testing to support Saltstone disposal Unit 5 design

    Energy Technology Data Exchange (ETDEWEB)

    Stefanko, D. B.; Langton, C. A.; Serrato, M. G.; Brooks, T. E. II; Huff, T. H.

    2013-02-24

    The Saltstone Facility, located within the Savannah River Site (SRS) near Aiken, South Carolina, consists of two facility segments: The Saltstone Production Facility (SPF) and the Saltstone Disposal Facility (SDF). The SPF receives decontaminated legacy low level sodium salt waste solution that is a byproduct of prior nuclear material processing. The salt solution is mixed with cementitious materials to form a grout slurry known as “Saltstone”. The grout is pumped to the SDF where it is placed in a Saltstone Disposal Unit (SDU) to solidify. SDU 6 is referred to as a “mega vault” and is currently in the design stage. The conceptual design for SDU 6 is a single cell, cylindrical geometry approximately 114.3 meters in diameter by 13.1 meter high and is larger than previous cylindrical SDU designs, 45.7 meters in diameter by 7.01 meters high (30 million gallons versus 2.9 million gallons of capacity). Saltstone slurry will be pumped into the new waste disposal unit through roof openings at a projected flow rate of about 34.1 cubic meters per hour. Nine roof openings are included in the design to discharge material into the SDU with an estimated grout pour radius of 22.9 to 24.4 meters and initial drop height of 13.1 meters. The conceptual design for the new SDU does not include partitions to limit the pour radius of the grout slurry during placement other than introducing material from different pour points. This paper addresses two technical issues associated with the larger diameter of SDU 6; saltstone flow distance in a tank 114.3 meters in diameter and quality of the grout. A long-radius flow test scaled to match the velocity of an advancing grout front was designed to address these technology gaps. The emphasis of the test was to quantify the flow distance and to collect samples to evaluate cured properties including compressive strength, porosity, density, and saturated hydraulic conductivity. Two clean cap surrogate mixes (saltstone premix plus water

  6. Grout Long Radius Flow Testing to Support Saltstone Disposal Unit 6 Design - 13352

    Energy Technology Data Exchange (ETDEWEB)

    Stefanko, D.B.; Langton, C.A.; Serrato, M.G. [Savannah River National Laboratory, Savannah River Nuclear Solutions, LLC, Savannah River Site, Aiken, SC 29808 (United States); Brooks, T.E. II; Huff, T.H. [Savannah River Remediation, LLC, Savannah River Site, Aiken, SC 29808 (United States)

    2013-07-01

    The Saltstone Facility, located within the Savannah River Site (SRS) near Aiken, South Carolina, consists of two facility segments: The Saltstone Production Facility (SPF) and the Saltstone Disposal Facility (SDF). The SPF receives decontaminated legacy low level sodium salt waste solution that is a byproduct of prior nuclear material processing. The salt solution is mixed with cementitious materials to form a grout slurry known as 'Saltstone'. The grout is pumped to the SDF where it is placed in a Saltstone Disposal Unit (SDU) to solidify. SDU 6 is referred to as a 'mega vault' and is currently in the design stage. The conceptual design for SDU 6 is a single cell, cylindrical geometry approximately 114.3 meters in diameter by 13.1 meter high and is larger than previous cylindrical SDU designs, 45.7 meters in diameter by 7.01 meters high (30 million gallons versus 2.9 million gallons of capacity). Saltstone slurry will be pumped into the new waste disposal unit through roof openings at a projected flow rate of about 34.1 cubic meters per hour. Nine roof openings are included in the design to discharge material into the SDU with an estimated grout pour radius of 22.9 to 24.4 meters and initial drop height of 13.1 meters. The conceptual design for the new SDU does not include partitions to limit the pour radius of the grout slurry during placement other than introducing material from different pour points. This paper addresses two technical issues associated with the larger diameter of SDU 6; Saltstone flow distance in a tank 114.3 meters in diameter and quality of the grout. A long-radius flow test scaled to match the velocity of an advancing grout front was designed to address these technology gaps. The emphasis of the test was to quantify the flow distance and to collect samples to evaluate cured properties including compressive strength, porosity, density, and saturated hydraulic conductivity. Two clean cap surrogate mixes (Saltstone premix

  7. Optical Coating Performance and Thermal Structure Design for Heat Reflectors of JWST Electronic Control Unit

    Science.gov (United States)

    Quijada, Manuel A.; Threat, Felix; Garrison, Matt; Perrygo, Chuck; Bousquet, Robert; Rashford, Robert

    2008-01-01

    The James Webb Space Telescope (JWST) consists of an infrared-optimized Optical Telescope Element (OTE) that is cooled down to 40 degrees Kelvin. A second adjacent component to the OTE is the Integrated Science Instrument Module, or ISIM. This module includes the electronic compartment, which provides the mounting surfaces and ambient thermally controlled environment for the instrument control electronics. Dissipating the 200 watts generated from the ISIM structure away from the OTE is of paramount importance so that the spacecraft's own heat does not interfere with the infrared light detected from distant cosmic sources. This technical challenge is overcome by a thermal subsystem unit that provides passive cooling to the ISIM control electronics. The proposed design of this thermal radiator consists of a lightweight structure made out of composite materials and low-emittance metal coatings. In this paper, we will present characterizations of the coating emittance, bidirectional reflectance, and mechanical structure design that will affect the performance of this passive cooling system.

  8. Design Choices for Thermofluid Flow Components and Systems that are Exported as Functional Mockup Units

    Energy Technology Data Exchange (ETDEWEB)

    Wetter, Michael; Fuchs, Marcus; Nouidui, Thierry

    2015-09-21

    This paper discusses design decisions for exporting Modelica thermofluid flow components as Functional Mockup Units. The purpose is to provide guidelines that will allow building energy simulation programs and HVAC equipment manufacturers to effectively use FMUs for modeling of HVAC components and systems. We provide an analysis for direct input-output dependencies of such components and discuss how these dependencies can lead to algebraic loops that are formed when connecting thermofluid flow components. Based on this analysis, we provide recommendations that increase the computing efficiency of such components and systems that are formed by connecting multiple components. We explain what code optimizations are lost when providing thermofluid flow components as FMUs rather than Modelica code. We present an implementation of a package for FMU export of such components, explain the rationale for selecting the connector variables of the FMUs and finally provide computing benchmarks for different design choices. It turns out that selecting temperature rather than specific enthalpy as input and output signals does not lead to a measurable increase in computing time, but selecting nine small FMUs rather than a large FMU increases computing time by 70%.

  9. Towards the formal specification of the requirements and design of a processor interface unit: HOL listings

    Science.gov (United States)

    Fura, David A.; Windley, Phillip J.; Cohen, Gerald C.

    1993-01-01

    This technical report contains the HOL listings of the specification of the design and major portions of the requirements for a commercially developed processor interface unit (or PIU). The PIU is an interface chip performing memory interface, bus interface, and additional support services for a commercial microprocessor within a fault-tolerant computer system. This system, the Fault-Tolerant Embedded Processor (FTEP), is targeted towards applications in avionics and space requiring extremely high levels of mission reliability, extended maintenance-free operation, or both. This report contains the actual HOL listings of the PIU specification as it currently exists. Section two of this report contains general-purpose HOL theories that support the PIU specification. These theories include definitions for the hardware components used in the PIU, our implementation of bit words, and our implementation of temporal logic. Section three contains the HOL listings for the PIU design specification. Aside from the PIU internal bus (I-Bus), this specification is complete. Section four contains the HOL listings for a major portion of the PIU requirements specification. Specifically, it contains most of the definition for the PIU behavior associated with memory accesses initiated by the local processor.

  10. Carbon capture test unit design and development using amine-based solid sorbent

    Energy Technology Data Exchange (ETDEWEB)

    Breault, Ronald W. [National Energy Technology Lab. (NETL), Morgantown, WV (United States); Spenik, James L. [REM Engineering Services, Morgantown, WV (United States); Shadle, Lawrence J. [National Energy Technology Lab. (NETL), Morgantown, WV (United States); Hoffman, James S. [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Gray, McMahan L. [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Panday, Rupen [REM Engineering Services, Morgantown, WV (United States); Stehle, Richard C. [ORISE, Morgantown, WV (United States)

    2016-06-30

    This study presents the design and development of a reactor system and the subsequent modifications to evaluate an integrated process to scrub carbon dioxide (CO2) from synthetic flue gas using amine based solid sorbents. The paper presents the initial system design and then discusses the various changes implemented to address the change in sorbent from a 180 μm Geldart group B material to a 115 μm Geldart group A material as well as issues discovered during experimental trials where the major obstacle in system operation was the ability to maintain a constant circulation of a solid sorbent stemming from this change in sorbent material. The system primarily consisted of four fluid beds, through which an amine impregnated solid sorbent was circulated and adsorption, pre-heat, regeneration, and cooling processes occurred. Instrumentation was assembled to characterize thermal, hydrodynamic, and gas adsorption performance in this integrated unit. A series of shakedown tests were performed and the configuration altered to meet the needs of the sorbent performance and achieve desired target capture efficiencies. Finally, methods were identified, tested, and applied to continuously monitor critical operating parameters including solids circulation rate, adsorbed and desorbed CO2, solids inventories, and pressures.

  11. Asynchronous Pipeline Micro—Control—Unit (MCU) Chip Design

    Institute of Scientific and Technical Information of China (English)

    ZHOUQian; XUKe; MINHao

    2003-01-01

    The work of this paper includes a researchon asynch ronous design methodology, and a design and implementation of an asynchronous 8-Bit micro-control-unit (MCU). This paper introduces a new application of New-Instruction-Fetching method to detect new instruc-tion which makes this chip fit for demand changeable sys-tem. The instruction set of this asynchronous MCU is compatible with PIC16C6X (Sicrochip Technology Inc).This paper also introduces a new architecture of pipeline,which increases the average speed of chip operation. The asynchronous low power MCU has been fabricated with CSMC (central semiconductor manufacturing corporation)0.6μm CMOS process in Aug 2001. The chip size is about 1.60mm*2.00mm (without taking account of PAD size).Now the test work has been accomplished and the test-ing result of this chip is also presented. The testing result shows that the asynchronous architecture could fulfill all the expected functions, additionally with higher processs peed and lower power consumption than its synchronous counterpart under the same supply voltage.

  12. Control structures design for fossil power station units; Diseno de estructuras de control para unidades termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Palomares Gonzalez, Daniel; Ricano Castillo, Juan Manuel [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1989-12-31

    In this paper are designed an analyzed the control ties of a 300MW fossil unit at different operation levels. The design and analysis were developed on an operation range of 50% to 100% load. The main control ties were studied among which are the feedwater flow, the superheating zone temperatures and the generated output. The technique used for the design is the decomposition in singular values (DSV) of the plant transference matrix. This is a recent technique that permits finding the most important interactions among output-input variables, over a significative frequencies range for the transference matrix of the plant. For this purpose utilizes the control properties of the transference matrix, such as: control effort, output-input interaction and ruggedness with respect to uncertainties. The control structures obtained were tested in a digital model of a fossil plant unit. A comparison study of both structures (original and modified) showed enhancement in the performance of the power plant with modified structure. [Espanol] En este trabajo se disenan y analizan los lazos de control de una unidad termoelectrica de 300 MW, a diferentes niveles de operacion. El diseno y analisis se desarrollo sobre un rango de operacion de 50 a 100 por ciento de carga. Se estudiaron los principales lazos de control entre los que se encuentran el flujo de agua de alimentacion, las temperaturas de la zona de sobrecalentamiento y la potencia generada. La tecnica utilizada para el diseno es la descomposicion en valores singulares (DVS) de la matriz de transferencia de la planta. Esta es una tecnica reciente que permite encontrar las interacciones mas importantes entre variables entrada-salida, sobre un rango de frecuencias significativas para la matriz de transferencia de la planta. Utiliza para ello las propiedades de control de la matriz de transferencia, como son: esfuerzo de control, interaccion entrada-salida y robustez con respecto a incertidumbres. Las estructuras de control

  13. Optimal design of compact organic Rankine cycle units for domestic solar applications

    Directory of Open Access Journals (Sweden)

    Barbazza Luca

    2014-01-01

    Full Text Available Organic Rankine cycle turbogenerators are a promising technology to transform the solar radiation harvested by solar collectors into electric power. The present work aims at sizing a small-scale organic Rankine cycle unit by tailoring its design for domestic solar applications. Stringent design criteria, i. e., compactness, high performance and safe operation, are targeted by adopting a multi-objective optimization approach modeled with the genetic algorithm. Design-point thermodynamic variables, e. g., evaporating pressure, the working fluid, minimum allowable temperature differences, and the equipment geometry, are the decision variables. Flat plate heat exchangers with herringbone corrugations are selected as heat transfer equipment for the preheater, the evaporator and the condenser. The results unveil the hyperbolic trend binding the net power output to the heat exchanger compactness. Findings also suggest that the evaporator and condenser minimum allowable temperature differences have the largest impact on the system volume and on the cycle performances. Among the fluids considered, the results indicate that R1234yf and R1234ze are the best working fluid candidates. Using flat plate solar collectors (hot water temperature equal to 75 °C, R1234yf is the optimal solution. The heat exchanger volume ranges between 6.0 and 23.0 dm3, whereas the thermal efficiency is around 4.5%. R1234ze is the best working fluid employing parabolic solar collectors (hot water temperature equal to 120 °C. In such case the thermal efficiency is around 6.9%, and the heat exchanger volume varies from 6.0 to 18.0 dm3.

  14. Application and design of induction machine damping unit (IMDU) for eliminating subsynchronous resonance

    Science.gov (United States)

    Purushothaman, Sujit

    The IEEE First and Second Benchmark Models for subsynchronous resonance (SSR) are used to analyze the damping properties of an induction machine damping unit (IMDU) coupled to the shaft of a turbo-generator set. This study investigates the rating and location of the induction machine that, without the aid of any controllers, effectively damps sub-synchronous resonance for all line series compensation levels. Eigenvalue analyses are performed on linearized models of the shaft system including the induction machine to find the optimum location. The best location of the IMDU, providing maximum damping, is next to the HP turbine at the end of the shaft. Time domain simulations are conducted to find the adequate rating of the induction machine. It is observed that a small size, high power (about 10% of the generator rating), low energy machine effectively damps SSR. The IMDU reduces peak torques in shaft sections during transients. In the study, it is demonstrated that the addition of an IMDU at the end of the shaft would have prevented the SSR events of 1970 and 1971 that caused major damage to the Mohave Desert generator shafts. A basic design of the IMDU is presented derived from a closed form solution of Maxwell's equations in squirrel cage induction motors. The solution is obtained for a cylindrical multi-layer geometry. The squirrel cage is represented by an equivalent anisotropic homogeneous medium. The effect of stator slots and teeth is included by a second anisotropic homogeneous medium. The induction motor is modeled as six concentric cylindrical layers representing the different construction components of the motor. The governing partial differential equations are solved for the excitation source, conducting and non-conducting regions. The formulas obtained allow for efficient calculations of machine performance which may help the motor designer to select the proper parameters of the machine that fit the design requirements. Accuracy of the modeling method

  15. 儿童重症监护病房2004至2009年下呼吸道常见革兰阴性杆菌感染分布与耐药监测%Common gram-negative bacilli lower respiratory tract infection in PICU: analysis of pathogens and drug resistant pattern from 2004 to 2009

    Institute of Scientific and Technical Information of China (English)

    郑静; 肖琴; 廖霓; 张宁; 张国英

    2010-01-01

    目的 探讨成都市儿童医院重症监护病房(PICU)痰标本分离的常见革兰阴性杆菌感染的菌群分布与耐药性变迁.方法 对2004年1月至2009年12月临床收集的合格痰标本分离出的常见革兰阴性杆菌耐药性进行回顾性分析,并比较2004至2006年、2007至2009年两个时段的菌群分布及耐药性变化.所有标本按标准微生物学方法进行定量、定性培养.连续两次培养,同一优势菌株为致病菌;并对所有鉴定所用试剂及药敏分析所用抗菌药物纸片进行质量控制.结果 6年共分离出革兰阴性杆菌598株,两个时段前5位均依次为大肠埃希菌167株(27.93%)、肺炎克雷白杆菌109株(18.23%)、阴沟肠杆菌93株(15.55%)、鲍曼不动杆菌64株(10.7%)、铜绿假单胞菌43株(7.19%).对亚胺培南、阿米卡星、哌拉西林/他唑巴坦较为敏感,而耐药率最高的药物为阿莫西林、氨苄西林、多种头孢菌素等.除铜绿假单胞菌、鲍曼不动杆菌外,未发现耐亚胺培南的革兰阴性菌株;2007至2009年肺炎克雷白杆菌及大肠埃希菌产超广谱β-内酰胺酶菌株检出率较2004至2006年明显上升.结论 与2004至2006年相比,2007至2009年本院PICU常见革兰阴性杆菌感染耐药率呈上升趋势,及时监测PICU病原菌耐药趋势变化对指导危重患儿合理用药致关重要.%Objective To study common Gram negative bacterial pathogens and their drug resistant pattern in sputum isolates from patients in pediatric intensive care unit (PICU) of Chengdu children' s hospital. Methods Comparing to the period of 2004-2006 with 2007-2009, we retrospectively reviewed eligible sputum isolates of common Gram negative bacilli and their drug resistance pattern. All specimens were processed according to standard microbiological methods for both quantitative and qualitative cultures. Pathogen was the single predominant growth after two consecutive cultures. Strict quality control was used in all test

  16. Comparison of maternal anxiety scores in pediatric intensive care unit and general ward parents

    Directory of Open Access Journals (Sweden)

    Lie Affendi Kartikahadi

    2012-02-01

    Full Text Available Background Hospitalization of a child is known to be a dreadful and stressful situation for parents. One study reported that admitting a child to a general ward caused mild anxiety to mothers, while admitting a child to the pediatric intensive care unit (PICU caused moderate anxiety to mothers. Objective To compare Hamilton anxiety scores of mothers whose children were admitted to the PICU to those of mothers whose children were admitted to the general ward. Methods A cross-sectional study was done on mothers of children aged 1 month-12 years. Children were admitted to either the intensive care unit or the general ward from October 2010-January 2011. All subjects were assessed by Hamilton anxiety scores and questioned for risk factors and other causes of maternal anxiety. Consecutive sampling was used to allocate the subjects. Differences were considered statistically significant for P < 0.05. Results Of the 72 subjects, the median Hamilton anxiety score in mothers of children admitted to the PICU was 20.5 (interquartile range 14-29.75, higher than that of mothers of children admitted to the general ward (14, interquartile range 9-16.75. Mann-Whitney U test revealed a statistically significant difference in scores between the two groups (P = 0.001. Ancova multivariate analysis showed the admission location to be the only significant relationship to Hamilton anxiety score (P = 0.0001. Conclusion Hamilton anxiety scores were higher for mothers of children admitted to the PICU than that of mothers with children admitted to the general ward. [Paediatr Indones.2012;52:95-8].

  17. A preliminary design and BOP cost analysis of M-C Power`s MCFC commerical unit

    Energy Technology Data Exchange (ETDEWEB)

    Chen, T.P. [Bechtel Corp, San Francisco, CA (United States)

    1996-12-31

    M-C Power Corporation plans to introduce its molten carbonate fuel cell (MCFC) market entry unit in the year 2000 for distributed and on-site power generation. Extensive efforts have been made to analyze the cell stack manufacturing costs. The major objective of this study is to conduct a detailed analysis of BOP costs based on an initial design of the market entry unit.

  18. Related factors and intervention of PICU poisoning in children%PICU中毒患儿相关因素分析及干预

    Institute of Scientific and Technical Information of China (English)

    王琪

    2014-01-01

    目的 总结PICU中毒患儿的相关因素,并提出针对性的干预措施.方法 回顾性分析中毒患儿的年龄、发病季节、中毒症状、中毒物质、中毒途径、治疗、转归等,并根据是否为药物中毒分为药物组和非药物组,比较两组不同特点.结果 药物中毒组81例,非药物中毒组54例.两组中毒表现和临床辅助检查差异无统计学意义(P>0.05).非药物中毒组治愈率和无效率分别为46.30%和1.85%,与药物中毒组相比差异无统计学意义(P>0.05).但是两组在呼吸机使用时间和血液净化治疗时间方面差异有统计学意义(P<0.05).从中毒主要因素来看,以家庭中毒为主(82.96%),农村中毒患儿比例较高(59.26%),药物中毒81例(60.00%).结论 针对儿童中毒发生的主要特点,要求家长必须做好相关化工产品的日常管理,掌握正确的药物使用知识,以降低儿童中毒发生风险.%Objective To summarize the relative factors of PICU poisoning,and then to propose some corresonding intervention measrues.Methods The age,onset season,poisoning symptom,poisoning substance,poisoning way,treatment,prognosis etc.of the poisoning children were retrospectively analyzed.The children were divided into a drug poisoning group and a non-drug poisoning group according to whether was drug poisoning.The different characteristics of the two groups were compared.Results The drug poisoning group had 81 patients,and the non-drug poisoning group 54 cases.There were no statistical differences in the poisoning manifestations and clinical examination between the two groups(P > 0.05).The cure rate and effectless rate of the non-drug poisoning group were 46.30% and 1.85%,respectively,which didn' t stattistically differ from that of the drug poisoning group (P > 0.05).However,there were statistical differences in the time of applying ventilator and blood purification time between the two groups (P < 0.05).The main poisoning factor

  19. Hospital malnutrition and inflammatory response in critically ill children and adolescents admitted to a tertiary intensive care unit

    OpenAIRE

    2008-01-01

    Critical illness has a major impact on the nutritional status of both children and adults. A retrospective study was conducted to evaluate the incidence of hospital malnutrition at a pediatric tertiary intensive care unit (PICU). Serum concentrations of IL-6 in subgroups of well-nourished and malnourished patients were also evaluated in an attempt to identify those with a potential nutritional risk. METHODS: A total of 1077 patients were enrolled. Nutritional status was evaluated by Z-score (...

  20. On Methods of Establishing Design Diagrams for Structural Integrity of Slender Complex Types of Breakwater Armour Units

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Howell, Gary J.

    1988-01-01

    units to measure bending movements in a cross section of the units and the accelerations (impact speed) were first used by DHL in 1980. Recent developments were presented by Scott et al. 1986. Correct scaling of the most important material properties of concrete in small scale hydraulic model tests...... was first presented by NRC (Timco 1981 ). Work based on direct strain-gauge measurement of stresses on large concrete model armour units was presented by Nishigori et al. in 1986.So far, none of the mentioned methods have produced general applicable tools for the design of armour layers. This is mainly......Many of the recent dramatic failures of a number of large rubble mound breakwaters armoured with Dolosse and Tetrapods were caused by breakage of the concrete armour units. Breakage took place before the hydraulic stability of intact units in the armour layers expired. Thus there was not a balance...

  1. Detailed design and first tests of the application software for the instrument control unit of Euclid-NISP

    Science.gov (United States)

    Ligori, S.; Corcione, L.; Capobianco, V.; Bonino, D.; Sirri, G.; Fornari, F.; Giacomini, F.; Patrizii, L.; Valenziano, L.; Travaglini, R.; Colodro, C.; Bortoletto, F.; Bonoli, C.; Chiarusi, T.; Margiotta, A.; Mauri, N.; Pasqualini, L.; Spurio, M.; Tenti, M.; Dal Corso, F.; Dusini, S.; Laudisio, F.; Sirignano, C.; Stanco, L.; Ventura, S.; Auricchio, N.; Balestra, A.; Franceschi, E.; Morgante, G.; Trifoglio, M.; Medinaceli, E.; Guizzo, G. P.; Debei, S.; Stephen, J. B.

    2016-07-01

    In this paper we describe the detailed design of the application software (ASW) of the instrument control unit (ICU) of NISP, the Near-Infrared Spectro-Photometer of the Euclid mission. This software is based on a real-time operating system (RTEMS) and will interface with all the subunits of NISP, as well as the command and data management unit (CDMU) of the spacecraft for telecommand and housekeeping management. We briefly review the main requirements driving the design and the architecture of the software that is approaching the Critical Design Review level. The interaction with the data processing unit (DPU), which is the intelligent subunit controlling the detector system, is described in detail, as well as the concept for the implementation of the failure detection, isolation and recovery (FDIR) algorithms. The first version of the software is under development on a Breadboard model produced by AIRBUS/CRISA. We describe the results of the tests and the main performances and budgets.

  2. United States Marine Corps Career Designation Board: Significant Factors in Predicting Selection

    Science.gov (United States)

    2014-03-01

    Total Force Data Warehouse USMC United States Marine Corps USNA United States Naval Academy WTI Weapons and Tactics Instructor XO...Tactics Instructor ( WTI ), Professional Military Education (PME) complete, and Special Education/Advanced Degree Programs’ graduates had a

  3. Linear control of a boiler-turbine unit: analysis and design.

    Science.gov (United States)

    Tan, Wen; Fang, Fang; Tian, Liang; Fu, Caifen; Liu, Jizhen

    2008-04-01

    Linear control of a boiler-turbine unit is discussed in this paper. Based on the nonlinear model of the unit, this paper analyzes the nonlinearity of the unit, and selects the appropriate operating points so that the linear controller can achieve wide-range performance. Simulation and experimental results at the No. 4 Unit at the Dalate Power Plant show that the linear controller can achieve the desired performance under a specific range of load variations.

  4. An Official American Thoracic Society/European Respiratory Society Workshop Report: Evaluation of Respiratory Mechanics and Function in the Pediatric and Neonatal Intensive Care Units.

    Science.gov (United States)

    Peterson-Carmichael, Stacey; Seddon, Paul C; Cheifetz, Ira M; Frerichs, Inéz; Hall, Graham L; Hammer, Jürg; Hantos, Zoltán; van Kaam, Anton H; McEvoy, Cindy T; Newth, Christopher J L; Pillow, J Jane; Rafferty, Gerrard F; Rosenfeld, Margaret; Stocks, Janet; Ranganathan, Sarath C

    2016-02-01

    Ready access to physiologic measures, including respiratory mechanics, lung volumes, and ventilation/perfusion inhomogeneity, could optimize the clinical management of the critically ill pediatric or neonatal patient and minimize lung injury. There are many techniques for measuring respiratory function in infants and children but very limited information on the technical ease and applicability of these tests in the pediatric and neonatal intensive care unit (PICU, NICU) environments. This report summarizes the proceedings of a 2011 American Thoracic Society Workshop critically reviewing techniques available for ventilated and spontaneously breathing infants and children in the ICU. It outlines for each test how readily it is performed at the bedside and how it may impact patient management as well as indicating future areas of potential research collaboration. From expert panel discussions and literature reviews, we conclude that many of the techniques can aid in optimizing respiratory support in the PICU and NICU, quantifying the effect of therapeutic interventions, and guiding ventilator weaning and extubation. Most techniques now have commercially available equipment for the PICU and NICU, and many can generate continuous data points to help with ventilator weaning and other interventions. Technical and validation studies in the PICU and NICU are published for the majority of techniques; some have been used as outcome measures in clinical trials, but few have been assessed specifically for their ability to improve clinical outcomes. Although they show considerable promise, these techniques still require further study in the PICU and NICU together with increased availability of commercial equipment before wider incorporation into daily clinical practice.

  5. Design upgrade of the ISOLDE target unit for HIE-ISOLDE

    Energy Technology Data Exchange (ETDEWEB)

    Montaño, J., E-mail: Jacobo.Montano@cern.ch [CERN, ISOLDE, CH-1211 Geneva 23 (Switzerland); Giles, T. [CERN, ISOLDE, CH-1211 Geneva 23 (Switzerland); Gottberg, A. [CERN, ISOLDE, CH-1211 Geneva 23 (Switzerland); Instituto de Estructura de la Materia, CSIC, 28006 Madrid (Spain)

    2013-12-15

    Highlights: • Requirements for a new target-source system for the radioactive facility HIE-ISOLDE. • For the upgraded facility a higher radiation field will be present. • The new design has to take into account the radiation field of the upgraded facility. -- Abstract: The High Intensity and Energy HIE-ISOLDE project is a major upgrade of the existing ISOLDE and REX-ISOLDE facilities with the objective of increasing the energy and the intensity of the delivered radioactive ion beams (RIB) [1]. In order to accommodate the future increase of primary beam intensity delivered by the new LINAC4 H{sup −} driver to the Proton Synchrotron Booster (PSB) [2] and from this to ISOLDE, a major study is being carried out to upgrade the existing designs of the ISOLDE target and its supporting infrastructure. In particular, the extraction optics plays an important role in the initial beam transport and the quality of the beam supplied to the mass separators. Important factors include the emittance of the beam and the beam profile to avoid beam losses. A new double electrode extraction system has been developed for simplifying and improving the interface between the target unit and the frontend (target coupling table). Numerical and experimental studies have been performed in order to define the new extraction geometry, and the coupling table has been adapted to keep the compatibility. An alternative heating system is under study. An electron bombardment heating system is being developed as an option for avoiding the employment of big cross section cables. The results of these studies and the mechanical models developed are presented and discussed.

  6. Role of design complexity in forecasting reliability and availability for electric-power-generating units. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Berkey, D.M.; Balaban, H.S.

    1982-10-01

    This report examines the relationship between design complexity and reliability and availability performance for fossil-fueled electric-power-generating units. Multivariate regression analysis was applied to design complexity and reliability and availability performance data gathered from a representative sample of electric-power-generating units. Twelve predictive relationships or equations were developed as a result of employing this statistical procedure. Each equation was verified and assessed. Guidelines for applying the predictive relationships, including confidence limits, were also developed and are presented in this report. A major result of this examination is a quantitative predictive tool that should be useful to the electric-power industry.

  7. The effect of sprue design and alloy type on the fit of three-unit metal/ceramic bridges.

    Science.gov (United States)

    Johnson, A

    1995-12-01

    This study was designed to compare the effect of three sprue designs and three types of metal alloy/ceramic on the accuracy of fit of three unit bridges. A sprue design which has straight sprues attached directly to the pattern but does not have a button of excess metal connecting the sprues together after casting, produced the best marginal accuracy, irrespective of the alloy type used. Of the three alloys used (gold, palladium and nickel/chromium based alloys) the gold alloy produced better fitting bridges with each sprue design used.

  8. Draft audit report, human factors engineering control room design review: Saint Lucie Nuclear Power Plant, Unit No. 2

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, L.R.; Lappa, D.A.; Moore, J.W.

    1981-09-03

    A human factors engineering preliminary design review of the Saint Lucie Unit 2 control room was performed at the site on August 3 through August 7, 1981. This design review was carried out by a team from the Human Factors Engineering Branch, Division of Human Factors Safety. This report was prepared on the basis of the HFEB's review of the applicant's Preliminary Design Assessment and the human factors engineering design review/audit performed at the site. The review team included human factors consultants from BioTechnology, Inc., Falls Church, Virginia, and from Lawrence Livermore National Laboratory (University of California), Livermore, California.

  9. Design upgrade of the ISOLDE target unit for HIE-ISOLDE

    CERN Document Server

    Montano, J; Gottberg, A

    2013-01-01

    The High Intensity and Energy HIE-ISOLDE project is a major upgrade of the existing ISOLDE and REX-ISOLDE facilities with the objective of increasing the energy and the intensity of the delivered radioactive ion beams (RIB) {[}1]. In order to accommodate the future increase of primary beam intensity delivered by the new LINAC4 H- driver to the Proton Synchrotron Booster (PSB) {[}2] and from this to ISOLDE, a major study is being carried out to upgrade the existing designs of the ISOLDE target and its supporting infrastructure. In particular, the extraction optics plays an important role in the initial beam transport and the quality of the beam supplied to the mass separators. Important factors include the emittance of the beam and the beam profile to avoid beam losses. A new double electrode extraction system has been developed for simplifying and improving the interface between the target unit and the frontend (target coupling table). Numerical and experimental studies have been performed in order to define ...

  10. A Single-Unit Design Structure and Gender Differences in the Swimming World Championships

    Science.gov (United States)

    Pushkar, Svetlana; Issurin, Vladimir B.; Verbitsky, Oleg

    2014-01-01

    Four 50 meter male/female finals - the freestyle, butterfly, breaststroke, and backstroke - swum during individual events at the Swimming World Championships (SWCs) can be defined in four clusters. The aim of the present study was to use a single-unit design structure, in which the swimmer was defined at only one scale, to evaluate gender differences in start reaction times among elite swimmers in 50 m events. The top six male and female swimmers in the finals of four swimming stroke final events in six SWCs were analyzed. An unpaired t-test was used. The p-values were evaluated using Neo-Fisherian significance assessments (Hurlbert and Lombardi, 2012). For the freestyle, gender differences in the start reaction times were positively identified for five of the six SWCs. For the backstroke, gender differences in the start reaction times could be dismissed for five of the six SWCs. For both the butterfly and breaststroke, gender differences in the start reaction times yielded inconsistent statistical differences. Pooling all swimmers together (df = 286) showed that an overall gender difference in the start reaction times could be positively identified: p = 0.00004. The contrast between the gender differences in start reaction times between the freestyle and backstroke may be associated with different types of gender adaptations to swimming performances. When the natural groupings of swimming stroke final events were ignored, sacrificial pseudoreplication occurred, which may lead to erroneous statistical differences. PMID:25414754

  11. A Single-Unit Design Structure and Gender Differences in the Swimming World Championships

    Directory of Open Access Journals (Sweden)

    Pushkar Svetlana

    2014-10-01

    Full Text Available Four 50 meter male/female finals - the freestyle, butterfly, breaststroke, and backstroke - swum during individual events at the Swimming World Championships (SWCs can be defined in four clusters. The aim of the present study was to use a single-unit design structure, in which the swimmer was defined at only one scale, to evaluate gender differences in start reaction times among elite swimmers in 50 m events. The top six male and female swimmers in the finals of four swimming stroke final events in six SWCs were analyzed. An unpaired t-test was used. The p-values were evaluated using Neo-Fisherian significance assessments (Hurlbert and Lombardi, 2012. For the freestyle, gender differences in the start reaction times were positively identified for five of the six SWCs. For the backstroke, gender differences in the start reaction times could be dismissed for five of the six SWCs. For both the butterfly and breaststroke, gender differences in the start reaction times yielded inconsistent statistical differences. Pooling all swimmers together (df = 286 showed that an overall gender difference in the start reaction times could be positively identified: p = 0.00004. The contrast between the gender differences in start reaction times between the freestyle and backstroke may be associated with different types of gender adaptations to swimming performances. When the natural groupings of swimming stroke final events were ignored, sacrificial pseudoreplication occurred, which may lead to erroneous statistical differences

  12. Remedial design work plan for Lower East Fork Poplar Creek Operable Unit, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The Remedial Design Work Plan (RDWP) for Lower East Fork Poplar Creek (EFPC) Operable Unit (OU) in Oak Ridge, Tennessee. This remedial action fits into the overall Oak Ridge Reservation (ORR) cleanup strategy by addressing contaminated floodplain soil. The objective of this remedial action is to minimize the risk to human health and the environment from contaminated soil in the Lower EFPC floodplain pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) and the Federal Facility Agreement (FFA) (1992). In accordance with the FFA, a remedial investigation (RI) (DOE 1994a) and a feasibility study (DOE 1994b) were conducted to assess contamination of the Lower EFPC and propose remediation alternatives. The remedial investigation determined that the principal contaminant is mercury, which originated from releases during Y-12 Plant operations, primarily between 1953 and 1963. The recommended alternative by the feasibility study was to excavate and dispose of floodplain soils contaminated with mercury above the remedial goal option. Following the remedial investigation/feasibility study, and also in accordance with the FFA, a proposed plan was prepared to more fully describe the proposed remedy.

  13. Design upgrade of the ISOLDE target unit for HIE-ISOLDE

    Science.gov (United States)

    Montaño, J.; Giles, T.; Gottberg, A.

    2013-12-01

    The High Intensity and Energy HIE-ISOLDE project is a major upgrade of the existing ISOLDE and REX-ISOLDE facilities with the objective of increasing the energy and the intensity of the delivered radioactive ion beams (RIB) [1]. In order to accommodate the future increase of primary beam intensity delivered by the new LINAC4 H- driver to the Proton Synchrotron Booster (PSB) [2] and from this to ISOLDE, a major study is being carried out to upgrade the existing designs of the ISOLDE target and its supporting infrastructure. In particular, the extraction optics plays an important role in the initial beam transport and the quality of the beam supplied to the mass separators. Important factors include the emittance of the beam and the beam profile to avoid beam losses. A new double electrode extraction system has been developed for simplifying and improving the interface between the target unit and the frontend (target coupling table). Numerical and experimental studies have been performed in order to define the new extraction geometry, and the coupling table has been adapted to keep the compatibility. An alternative heating system is under study. An electron bombardment heating system is being developed as an option for avoiding the employment of big cross section cables. The results of these studies and the mechanical models developed are presented and discussed.

  14. [Testing system design and analysis for the execution units of anti-thrombotic device].

    Science.gov (United States)

    Li, Zhelong; Cui, Haipo; Shang, Kun; Liao, Yuehua; Zhou, Xun

    2015-02-01

    In an anti-thrombotic pressure circulatory device, relays and solenoid valves serve as core execution units. Thus the therapeutic efficacy and patient safety of the device will directly depend on their performance. A new type of testing system for relays and solenoid valves used in the anti-thrombotic device has been developed, which can test action response time and fatigue performance of relay and solenoid valve. PC, data acquisition card and test platform are used in this testing system based on human-computer interaction testing modules. The testing objectives are realized by using the virtual instrument technology, the high-speed data acquisition technology and reasonable software design. The two sets of the system made by relay and solenoid valve are tested. The results proved the universality and reliability of the testing system so that these relays and solenoid valves could be accurately used in the antithrombotic pressure circulatory equipment. The newly-developed testing system has a bright future in the aspects of promotion and application prospect.

  15. Design galvanometer position detection unit based on single detector compound axis tracking system

    Science.gov (United States)

    Liu, Yang; Tong, Shoufeng; Song, Yansong; Chang, Shuai; Gao, Yinan; Zhao, Kewei

    2016-10-01

    The fine tracking unit of composite axis of acquisition, pointing and tracking(APT) is a key component of space laser communication system. In order to prevent the principal axis in open-loop without proper input of control after started the tracking of auxiliary axis, which led to the target out of field. In a single detector composite shaft structure, we need to provide the accurate position of PZT volume feedback for the principle axis to control. This article has made an galvanometer position detective method of the single detector composite shaft structure. It provided the theory of circuit design and optimization plan. Researchers conducted a multiple sets of experiments. The experimental result shows that the galvanometer 1 "per deflection Angle, the detection circuit can retrieve 13 mV voltage change. At the same time, compared with the traditional camera calibration, we put forward a new calibration method which using optical autocollimator that the maximum error control within 1 ". Finally, the control formula is given and the error should be within 0.01mrad. So that the calibration precision of the detecting plate is improved.

  16. Nuclear design report for Kori nuclear power plant unit 1, cycle 14

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Oh; Kim, Joo Young; Park, Sang Yoon; Song, Jae Woong; Lee, Chong Chul; Baik, Joo Hyun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-06-01

    This report presents nuclear design calculations for cycle 14 of Kori unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 44 KOFA`s enriched by nominally 3.70 w/o U{sub 235}. Among the KOFA`s, 16 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of cycle 14 amounts to 366 EFPD corresponding to a cycle burnup of 13680 MWD/MTU. (Author) 8 refs., 55 figs., 16 tabs. nozzle by vortex formation during mid-loop operation condition are experimentally investigated. The critical submergence is determined for various types of suction nozzle, and the measurements of velocity distribution are performed in the flow fields near the t-shaped suction nozzle. (Author) 11 refs., 41 figs., 13 tabs.

  17. Design of high energy density thermoelectric energy conversion unit by using FGM compliant pads

    CERN Document Server

    Kambe, M

    1999-01-01

    In order to provide increasingly large amounts of electrical power to space and terrestrial systems with a sufficiently high level of reliability at a reasonable cost, thermoelectric (TE) energy conversion system by using $9 functionally graded material (FGM) compliant pads has been focused. To achieve high thermal energy density in TE power conversion systems, conductively coupling the TE units to the hot and cold heat exchangers is the most effective $9 configuration. This is accomplished by two sets of FGM compliant pads. This design strategy provides (1) a high flux, direct conduction path to heat source and heat sink, (2) the structural flexibility to protect the cell from high $9 stress due to thermal expansion, (3) an extended durability by a simple FGM structure, and (4) manufacturing cost reduction by spark plasma sintering. High thermal energy density of ten times as much as conventional radioisotope $9 thermoelectric generator is expected. Manufacturing of Cu/Al/sub 2/O/sub 3//Cu symmetrical FGM co...

  18. Design Analysis of Power Extracting Unit of an Onshore OWC Based Wave Energy Power Plant using Numerical Simulation

    Directory of Open Access Journals (Sweden)

    Zahid Suleman

    2011-07-01

    Full Text Available This research paper describes design and analysis of power extracting unit of an onshore OWC (Oscillating Water Column based wave energy power plant of capacity about 100 kilowatts. The OWC is modeled as solid piston of a reciprocating pump. The power extracting unit is designed analytically by using the theory of reciprocating pumps and principles of fluid mechanics. Pro-E and ANSYS workbench softwares are used to verify the analytical design. The analytical results of the flow velocity in the turbine duct are compared with the simulation results. The results are found to be in good agreement with each other. The results achieved by this research would finally assist in the overall design of the power plant which is the ultimate goal of this research work.

  19. 论网站页面设计的一致性原则%Principle of the United Webpage Design

    Institute of Scientific and Technical Information of China (English)

    华晓清

    2009-01-01

    With the development of IT and e-commerce, the webpage design is becoming more and more important. Several issues may be concerned with a good webpage design, while one of the most fundamental principles is to create united pages. Four aspects including page layout design, color design, guidance design and the design of the function of some standard elements on the page, are considered for a united but also varied webpage design. Consistent pages are not always good because visual fatigue may happen. From the above discus-sions, essential understandings to the importance of united webpage principle are strengthened and lead to a united webpage design process.%随着网络技术与电子商务的发展,网站页面设计也越来越受重视,优秀的网页虽然各有特色,但都遵守最基本的原则即保证页面的一致性.通过从页面结构、色彩、导航栏以及页面标准元素功能四个角度分析应如何设计网站页面,既保证页面之间的一致性,又使得读者不会因页面风格过于一致而产生视觉疲劳,并在此基础上提出了一个基本的保证页面一致性的设计方法.

  20. ATLID receiving spatial and spectral filtering units: design and associated performances

    Science.gov (United States)

    Vaché, Maxime; de Saint Seine, Diego; Leblay, Pierrick; Hélière, Arnaud; Pereira Do Carmo, João.; Berlioz, Philippe; Archer, Julien

    2015-09-01

    ATLID (ATmospheric LIDar) is one of the four key instruments of EarthCARE (Earth Clouds, Aerosols and Radiations Explorer) satellite. It is a program of and funded by the European Space Agency and under prime contractorship of Airbus Defence and Space. ATLID is dedicated to the understanding of aerosols and clouds contribution to earth climate. It is an atmospheric LIDAR that measures the emitted 354.8nm ultraviolet laser which is backscattered by the atmosphere. The molecules and the particles have different optical signatures and can consequently be distinguished thanks to polarization analyses and spectral filtering of the backscattered signal. The following optical units of ATLID receiver chain directly contribute to this function : after ATLID afocal telescope, the CAS-OA, the Optical Assembly of the Co Alignment Sensor, samples and images the beam on the CAS sensor in order to optimize the alignment of transmitting and receiving telescopes. The beam goes through the BF sub-assemblies, the Blocking Filter which has two filtering functions: (1) spatial with the ERO-BF, which is a Kepler afocal spatial filtering module that defines the instrument field of view and blocks the background and straylight out of the useful field of view; (2) spectral with the ERO-EFO, the Entrance Filtering Optic, which is mainly composed of a very narrow bandpass filter with a high rejection factor. This filter rejects the background from the useful signal and contributes to increase the signal-to-noise ratio. The EFO also allows an on-ground adjustment of the orientation of the linear polarization of the input beam. After filtering and polarization adjustment, the beam is injected in several optical fibers and transported to the instrument detectors. This last transport function is done by the FCA, the Fiber Coupler Assembly. This paper presents the flight models of the previously described units, details the opto-mechanical design, and reviews the main achieved performances with a

  1. The design of a photodetector unit of a new Shashlyk EM calorimeter for COMPASS II

    Energy Technology Data Exchange (ETDEWEB)

    Chirikov-Zorin, I., E-mail: chirikov@nusun.jinr.ru; Krumshtein, Z.; Olchevski, A.

    2016-07-11

    A nine-channel photodetector unit with micropixel avalanche photodiodes (MAPD) and precision thermostabilization based on the compact Peltier module is designed and constructed. MAPD-3N with a high pixel density of 15,000 per square mm and area 3×3 mm{sup 2} produced by Zecotek were used.

  2. Engineering Encounters: The Cat in the Hat Builds Satellites. A Unit Promoting Scientific Literacy and the Engineering Design Process

    Science.gov (United States)

    Rehmat, Abeera P.; Owens, Marissa C.

    2016-01-01

    This column presents ideas and techniques to enhance your science teaching. This month's issue shares information about a unit promoting scientific literacy and the engineering design process. The integration of engineering with scientific practices in K-12 education can promote creativity, hands-on learning, and an improvement in students'…

  3. MEGARA optical design: the new integral field unit and multi-object spectrograph for the GTC 10m telescope

    Science.gov (United States)

    García-Vargas, María. Luisa; Sánchez-Blanco, Ernesto; Carrasco, Esperanza; Gil de Paz, Armando; Páez, Gonzalo; Pérez, Ana; Gallego, Jesús; Sánchez, Francisco; Vílchez, José M.

    2012-12-01

    We describe the optical design of MEGARA, the future optical Integral Field Unit (IFU) and Multi-Object Spectrograph (MOS) for the 10.4-m Gran Telescopio CANARIAS (GTC). MEGARA is being built by a Consortium of public research institutions led by the Universidad Complutense de Madrid (UCM, Spain) that also includes INAOE (Mexico), IAA-CSIC (Spain) and UPM (Spain).

  4. Optimal integrated design of air separation unit and gas turbine block for IGCC systems

    Energy Technology Data Exchange (ETDEWEB)

    Kamath, R.; Grossman, I.; Biegler, L.; Zitney, S.

    2009-01-01

    The Integrated Gasification Combined Cycle (IGCC) systems are considered as a promising technology for power generation. However, they are not yet in widespread commercial use and opportunities remain to improve system feasibility and profitability via improved process integration. This work focuses on the integrated design of gasification system, air separation unit (ASU) and the gas turbine (GT) block. The ASU supplies oxygen to the gasification system and it can also supply nitrogen (if required as a diluent) to the gas turbine block with minimal incremental cost. Since both GT and the ASU require a source of compressed air, integrating the air requirement of these units is a logical starting point for facility optimization (Smith et al., 1997). Air extraction from the GT can reduce or avoid the compression cost in the ASU and the nitrogen injection can reduce NOx emissions and promote trouble-free operation of the GT block (Wimer et al., 2006). There are several possible degrees of integration between the ASU and the GT (Smith and Klosek, 2001). In the case of 'total' integration, where all the air required for the ASU is supplied by the GT compressor and the ASU is expected to be an elevated-pressure (EP) type. Alternatively, the ASU can be 'stand alone' without any integration with the GT. In this case, the ASU operates at low pressure (LP), with its own air compressor delivering air to the cryogenic process at the minimum energy cost. Here, nitrogen may or may not be injected because of the energy penalty issue and instead, syngas humidification may be preferred. A design, which is intermediate between these two cases, involves partial supply of air by the gas turbine and the remainder by a separate air compressor. These integration schemes have been utilized in some IGCC projects. Examples include Nuon Power Plant at Buggenum, Netherlands (both air and nitrogen integration), Polk Power Station at Tampa, US (nitrogen-only integration) and

  5. Needs of Parents in Caring for Their Children in a Pediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Mery Luz Valderrama Sanabria

    Full Text Available Objective.This work sought to describe the needs of parents to participate in caring for their children hospitalized in a pediatric intensive care unit (PICU. Methods. This is a qualitative study based on the ethno-nursing research method proposed by Leininger. For data collection and analysis, in-depth open interviews were used, along with field notes and enabler guidelines proposed by Leininger: stranger-friend, observation, participation, reflexion, and the Sunrise model. Parents of children hospitalized in a PICU in the city of Tunja (Boyacá, Colombia participated between February 2012 and October 2013. Results. The needs of parents to care for their children were described in the following themes: clear and timely communication, familiarization with technology, the value of the family, favoring the parent-children interaction during visits, and valuing and respecting generic (folk knowledge. Conclusion. The study provides knowledge, from the cultural perspective of parents with children hospitalized in PICU, as input to plan and develop care actions with them, according to their own needs.

  6. Relation between safe use of medicines and Clinical Pharmacy Services at Pediatric Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Lucas Miyake Okumura

    Full Text Available Abstract Objective: Clinical Pharmacy Services (CPS are considered standard of care and is endorsed by the Joint Commission International, the American Academy of Pediatrics, and the American College of Clinical Pharmacy. In Brazil, single experiences have been discreetly arising and the importance of these services to children and adolescents care has led to interesting results, but certainly are under reported. This short report aims to discuss the effect of implementing a bedside CPS at a Brazilian Pediatric Intensive Care Unit (PICU. Methods: This is a cross-sectional study conducted in a 12 bed PICU community hospital, from Campo Largo/Brazil. Subjects with<18 years old admitted to PICU were included for descriptive analysis if received a CPS intervention. Results: Of 53 patients accompanied, we detected 141 preventable drug-related problems (DRPs which were solved within clinicians (89% acceptance of all interventions. The most common interventions performed to improve drug therapy included: preventing incompatible intravenous solutions (21% and a composite of inadequate doses (17% due to low, high and non-optimized doses. Among the top ten medications associated with DRPs, five were antimicrobials. By analyzing the correlation between DRPs and PICU length of stay, we found that 74% of all variations on length of stay were associated with the number of DRPs. Conclusions: Adverse drug reactions due to avoidable DRPs can be prevented by CPS in a multifaceted collaboration with other health care professionals, who should attempt to use active and evidence-based strategies to reduce morbidity related to medications.

  7. Parent Participation in Pediatric Intensive Care Unit Rounds via Telemedicine: Feasibility and Impact.

    Science.gov (United States)

    Yager, Phoebe H; Clark, Maureen; Cummings, Brian M; Noviski, Natan

    2017-06-01

    To evaluate feasibility and impact of telemedicine for remote parent participation in pediatric intensive care unit (PICU) rounds when parents are unable to be present at their child's bedside. Parents of patients admitted to a 14-bed PICU were approached, and those unable to attend rounds were eligible subjects. Nurse and physician caregivers were also surveyed. Parents received an iPad (Apple Inc, Cupertino, California) with an application enabling audio-video connectivity with the care team. At a predetermined time for bedside rounds with the PICU team, parents entered a virtual meeting room to participate. Following each telemedicine encounter, participants (parent, physician, nurse) completed a brief survey rating satisfaction (0?=?not satisfied, 10?=?completely satisfied) and disruption (0?=?no disruption at all, 10?=?very disruptive). A total of 153 surveys were completed following 51 telemedicine encounters involving 13 patients. Parents of enrolled patients cited work demands (62%), care for other dependents (46%), and transportation difficulties (31%) as reasons for study participation. The median levels of satisfaction and disruption were 10 (range 5-10) and 0 (range 0-5), respectively. All parents reported that telemedicine encounters had a positive effect on their level of reassurance regarding their child's care and improved communication with the care team. This proof-of-concept study indicates that remote parent participation in PICU rounds is feasible, enhances parent-provider communication, and offers parents reassurance. Providers reported a high level of satisfaction with minimal disruption. Technological advancements to streamline teleconferencing workflow are needed to ensure program sustainability. Copyright © 2017. Published by Elsevier Inc.

  8. Modern technologies for rendering information support to cogeneration steam turbine units in their design and operation stages

    Science.gov (United States)

    Brezgin, V. I.; Brodov, Yu. M.; Chubarov, A. A.; Brezgin, D. V.

    2013-08-01

    Application of modern information technologies in different stages of the lifecycle of cogeneration turbines is considered as one of possible ways for improving their competitiveness. Specific features relating to rendering information support for steam turbine units during the periods of their design and operation, which are the main stages of their life cycle, are presented. Three-dimension modeling, adaptive, and parametric design technologies are applied in the equipment design stages. Information support technologies developed by the authors are applied during the operation stage. Information is integrated by using a product lifecycle management (PLM) system.

  9. Optical design of a 4-off-axis-unit Cassegrain ultra-high concentrator photovoltaics module with a central receiver.

    Science.gov (United States)

    Ferrer-Rodríguez, Juan P; Fernández, Eduardo F; Almonacid, Florencia; Pérez-Higueras, Pedro

    2016-05-01

    Ultra-high concentrator photovoltaics (UHCPV), with concentrations higher than 1000 suns, have been pointed out by different authors as having great potential for being a cost-effective PV technology. This Letter presents a UHCPV Cassegrain-based optical design in which the sunrays are concentrated and sent from four different and independent paraboloid-hyperboloid pairs optical units onto a single central receiver. The optical design proposed has the main advantage of the achievement of ultra-high concentration ratios using relative small mirrors with similar performance values of efficiency, acceptance angle, and irradiance uniformity to other designs.

  10. Optimal design of unit hydrographs using probability distribution and genetic algorithms

    Indian Academy of Sciences (India)

    Rajib Kumar Bhattacharjya

    2004-10-01

    A nonlinear optimization model is developed to transmute a unit hydrograph into a probability distribution function (PDF). The objective function is to minimize the sum of the square of the deviation between predicted and actual direct runoff hydrograph of a watershed. The predicted runoff hydrograph is estimated by using a PDF. In a unit hydrograph, the depth of rainfall excess must be unity and the ordinates must be positive. Incorporation of a PDF ensures that the depth of rainfall excess for the unit hydrograph is unity, and the ordinates are also positive. Unit hydrograph ordinates are in terms of intensity of rainfall excess on a discharge per unit catchment area basis, the unit area thus representing the unit rainfall excess. The proposed method does not have any constraint. The nonlinear optimization formulation is solved using binary-coded genetic algorithms. The number of variables to be estimated by optimization is the same as the number of probability distribution parameters; gamma and log-normal probability distributions are used. The existing nonlinear programming model for obtaining optimal unit hydrograph has also been solved using genetic algorithms, where the constrained nonlinear optimization problem is converted to an unconstrained problem using penalty parameter approach. The results obtained are compared with those obtained by the earlier LP model and are fairly similar.

  11. Elementary Education Teacher Candidates' Integration of Technology in the Design of Interdisciplinary Units

    Science.gov (United States)

    Polly, Drew; Rock, Tracy

    2016-01-01

    In this paper the authors evaluate 85 elementary education teacher candidates' integration of technology into interdisciplinary units that the candidates wrote during the semester before their full-time student teaching internship. An inductive analysis of the units revealed that teachers used a wide variety of technologies with a large dependence…

  12. Assessment and Design of Illumination in the Unit of Carbon Dioxide Gas of Khuzestan Zam Zam Company

    Directory of Open Access Journals (Sweden)

    Rangkooy

    2015-04-01

    Full Text Available Background Light is the first that necessary for any effort. This factor, more than any physical variable, affects human labor. Two properties of cognitive and psychological lighting in the workplace can affect human performance. Objectives This study aimed to assess the illuminance in CO2 Gas unit of Khuzestan Zam Zam Company, and resolve its light deficiency through artificial lighting design. Materials and Methods This study is a descriptive-analytical based on survey of natural and artificial lighting sources in the workplace. It also included measurement of lighting levels in 3 shifts, calculating the average illuminance and comparing with recommended values, drawing graphs of results measured illuminance and finally designing the lighting of the unit by lumen method with room index (Kr. The study was conducted between March and June 2006 and its data were analyzed with 1-way analysis of variance (ANOVA. Results Mean ± SD level of illuminance in the morning, evening, and night was 211.31 ± 292.07, 182.16 ± 205.16, 67.47 ± 71.10 (lx, respectively. The results showed that there is a significant difference (P < 0.001 between average illuminance of 3 shifts of morning (day light, evening, and night (artificial light and the standard illuminance value (300 lx, which entails the lighting design’s work area for this unit. According to the design of artificial lighting base on the lumen method calculations in CO2 Gas unit, 400, 250 watt Metal Halides and 10585 watt compact fluorescent lamps were required, which their numbers were 610 and 44, respectively. Conclusions This paper considered the method based on comprehensive surveys of workplace illuminance levels (natural light and artificial light and design of lighting system as one of workplace physical factors in order to increase the efficiency of the production unit, decrease in carelessness, fatigue errors, and work accident.

  13. A prospective, longitudinal study to assess use of continuous and reactive low-pressure mattresses to reduce pressure ulcer incidence in a pediatric intensive care unit

    OpenAIRE

    García Molina, Pablo; Balaguer López, Evelin; Torra i Bou, Joan Enric; Álvarez Ordiales, Adán; Quesada Ramos, Cristina; Verdú Soriano, José

    2012-01-01

    Pressure between bony prominences and sleep surfaces, as well as pressure from the use of medical devices, put children admitted to pediatric intensive care units (PICUs) at risk of developing pressure ulcers (PUs). To assess the effect of two pediatric-specific, continuous and reactive low-pressure mattresses on the incidence of PUs, an observational, descriptive, prospective, longitudinal (2009–2011) study was conducted among PICU patients. The two pediatric mattresses — one for children we...

  14. Bringing Engineering Design into High School Science Classrooms: The Heating/Cooling Unit

    Science.gov (United States)

    Apedoe, Xornam S.; Reynolds, Birdy; Ellefson, Michelle R.; Schunn, Christian D.

    2008-01-01

    Infusing engineering design projects in K-12 settings can promote interest and attract a wide range of students to engineering careers. However, the current climate of high-stakes testing and accountability to standards leaves little room to incorporate engineering design into K-12 classrooms. We argue that design-based learning, the combination…

  15. On the Organization Design of United Enterprise%论联合企业组织设计

    Institute of Scientific and Technical Information of China (English)

    刘巨钦; 娄俊; 杨阳

    2014-01-01

    联合企业组织设计以联合产权制度、联合组织结构、联合治理机制、联合要素禀赋和联合竞争机制五个核心维度为基石,通过价值链联合、生产融合、营销融合、后勤联合、人力资源联合和文化融合等平台来运作。联合企业组织设计的提出突破了单纯理性和刚性的组织设计,改变了企业竞争优势的生成模式,改变了市场竞争形态,适应了经济全球化、信息化、高技术化和全面市场改革的大背景,能指导组织在既独立又联合的环境下形成新的竞争优势。%The organization design of united enterprise is based on five core dimensions,and they are the united property rights institution,the united organization structure,the united governance mechanism,the united factor endowment and the united competition mechanism.It operates through these platforms including value chain uni-ty,production integration,marketing integration,logistics unity,human resources unity,culture integration and so on.The proposal of organization design of united enterprise breaks through the purely rational and rigid organi-zation design and changes the generating mode of enterprise's competitive advantages and the pattern of market competition.It adapts to the background of economic globalization,informationization,high technology and com-prehensive market reform,and can guide the organization to form the new competitive advantages in both inde-pendent and united environment.

  16. Risk of mortality in pediatric intensive care unit, assessed by PRISM-III.

    Science.gov (United States)

    Bilan, N; Galehgolab, B A; Emadaddin, A; Shiva, Sh

    2009-03-15

    This study aimed at evaluating the mortality rate in a PICU applying PRISM-III. Two hundred and twenty one infants and children consecutively admitted to PICU of Tabriz Children's Hospital were studied during a 13 months period of time. Data required for calculating the PRISM-III score were collected during the first 24 h of PICU stay in all patients. The prediction of actual mortality by PRISM-III scoring was evaluated by the Hosmer and Lemeshow goodness-of-fit test. Receiver Operating Characteristic (ROC) curve was constructed, as well. The observed (O) short-term (during hospital stay) mortality rate was compared with the expected (E) figures as the O/E ratio. The mean value of the PRISM-III score was 14.22 +/- 9.57(2-42). ROC analysis indicated a strong predictive power for the PRISM-III (area under the curve = 0.898) and the test was well fit to the designed study (goodness-of-fit p-value = 0.161). The observed short-term mortality rate was 9.05% and the expected mortality rate by the PRISM-III scoring was 9% (O/E ratio = 1.005). The PRISM-III scoring system was highly calibrated in our institute.

  17. Retail marijuana purchases in designer and commercial markets in New York City: sales units, weights, and prices per gram.

    Science.gov (United States)

    Sifaneck, Stephen J; Ream, Geoffrey L; Johnson, Bruce D; Dunlap, Eloise

    2007-09-01

    This paper documents the bifurcation of the market for commercial marijuana from the market for designer marijuana in New York City. Commercial marijuana is usually grown outdoors, imported to NYC, and of average quality. By contrast, several varities of designer marijuana are usually grown indoors from specially bred strains and carefully handled for maximum quality. The mechanisms for marijuana sales include street/park sellers, delivery services, private sales, and storefronts. Retail sales units vary from 5 dollars to 50 dollars and more, but the actual weights and price per gram of retail marijuana purchases lacks scientific precision. Ethnographic staff recruited marijuana purchasers who used digital scales to weigh a purposive sample of 99 marijuana purchases. Results indicate clear differences in price per gram between the purchases of commercial (average 8.20 dollars/g) and designer (average 18.02 dollars/g) marijuana. Designer purchases are more likely to be made by whites, downtown (Lower East Side/Union Square area), via delivery services, and in units of 10 dollar bags, 50 dollar cubes, and eighth and quarter ounces. Commercial marijuana purchases are more likely to be made by blacks, uptown (Harlem), via street dealers, and in units of 5 dollar and 20 dollar bags. Imported commercial types Arizona and Chocolate were only found uptown, while designer brand names describing actual strains like Sour Diesel and White Widow were only found downtown. Findings indicate clear divisions between commercial and designer marijuana markets in New York City. The extent that these differences may be based upon different THC potencies is a matter for future research.

  18. Design of a Mathematical Unit in FPGA for the Implementation of the Control of a Magnetic Levitation System

    Directory of Open Access Journals (Sweden)

    Juan José Raygoza-Panduro

    2008-01-01

    Full Text Available This paper presents the design and implementation of an automatically generated mathematical unit, from a program developed in Java that describes the VHDL circuit, ready to be synthesized with the Xilinx ISE tool. The core contains diverse complex operations such as mathematical functions including sine and cosine, among others. The proposed unit is used to synthesize a sliding mode controller for a magnetic levitation system. This kind of systems is used in industrial applications requiring high level of mathematical calculations in small time periods. The core is designed to calculate trigonometric and arithmetic operations in such a way that each function is performed in a clock cycle. In this paper, the results of the mathematical core are shown in terms of implementation, utilization, and application to control a magnetic levitation system.

  19. System and Software Design for the Plant Protection System for Shin-Hanul Nuclear Power Plant Units 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, In Seok; Kim, Young Geul; Choi, Woong Seock; Sohn, Se Do [KEPCO EnC, Daejeon (Korea, Republic of)

    2015-10-15

    The Reactor Protection System(RPS) protects the core fuel design limits and reactor coolant system pressure boundary for Anticipated Operational Occurrences (AOOs), and provides assistance in mitigating the consequences of Postulated Accidents (PAs). The ESFAS sends the initiation signals to Engineered Safety Feature - Component Control System (ESF-CCS) to mitigate consequences of design basis events. The Common Q platform Programmable Logic Controller (PLC) was used for Shin-Wolsung Nuclear Power Plant Units 1 and 2 and Shin-Kori Nuclear Power Plant Units 1, 2, 3 and 4 since Digital Plant Protection System (DPPS) based on Common Q PLC was applied for Ulchin Nuclear Power Plant Units 5 and 6. The PPS for Shin-Hanul Nuclear Power Plant Units 1 and 2 (SHN 1 and 2) was developed using POSAFE-Q PLC for the first time for the PPS. The SHN1 and 2 PPS was delivered to the sites after completion of Man Machine Interface System Integrated System Test (MMIS-IST). The SHN1 and 2 PPS was developed to have the redundancy in each channel and to use the benefits of POSAFE-Q PLC, such as diagnostic and data communication. The PPS application software was developed using ISODE to minimize development time and human errors, and to improve software quality, productivity, and reusability.

  20. Remedial Design/Remedial Action Work Plan for Operable Units 6-05 and 10-04, Phase III

    Energy Technology Data Exchange (ETDEWEB)

    R. P. Wells

    2006-09-19

    The remedial design/remedial action for Operable Unit 6-05 (Waste Area Group 6) and Operable Unit 10-04 (Waste Area Group 10) - collectively called Operable Unit 10-04 has been divided into four phases. Phase I consists of developing and implementing institutional controls at Operable Unit 10-04 sites and developing and implementing Idaho National Laboratory-wide plans for both institutional controls and ecological monitoring. Phase II will remediate sites contaminated with trinitrotoluene and Royal Demolition Explosive. Phase III will remediate lead contamination at a gun range, and Phase IV will remediate hazards from unexploded ordnance. This Phase III remedial Design/Remedial Action Work Plan addresses the remediation of lead-contaminated soils found at the Security Training Facility (STF)-02 Gun Range located at the Idaho National Laboratory. Remediation of the STF-02 Gun Range will include excavating contaminated soils; physically separating copper and lead for recycling; returning separated soils below the remediation goal to the site; stabilizing contaminated soils, as required, and disposing of the separated soils that exceed the remediation goal; encapsulating and disposing of creosote-contaminated railroad ties and power poles; removing and disposing of the wooden building and asphalt pads found at the STF-02 Gun Range; sampling and analyzing soil to determine the excavation requirements; and when the remediation goals have been met, backfilling and contouring excavated areas and revegetating the affected area.

  1. On Methods of Establishing Design Diagrams for Structural Integrity of Slender Complex Types of Breakwater Armour Units

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Howell, Gary J.

    1988-01-01

    was first presented by NRC (Timco 1981 ). Work based on direct strain-gauge measurement of stresses on large concrete model armour units was presented by Nishigori et al. in 1986.So far, none of the mentioned methods have produced general applicable tools for the design of armour layers. This is mainly...... by other researchers, it might be a frame for a uniform presentation of results. Without a uniformity it will take much longer before the oncoming data on structural integrity can be made useful through contributions to the future data bank which will be needed as a design tool....

  2. DESIGN NOTE: A video synchronization unit for capture of pulsed laser parameters

    Science.gov (United States)

    Oak, S. M.; Navathe, C. P.

    1996-04-01

    An electronic circuit called a video synchronization unit (VSU) is developed to synchronize TV grade CCTV cameras, CCTV monitors and video frame grabbers for the capture of pulsed laser parameters. The VSU accepts a video signal from the camera and generates triggers for the laser and frame grabber at required times. It also generates a trigger at any pre-set horizontal line in the video signal, so that the intensity profile of the selected line can be viewed on an oscilloscope. The unit can drive a laser or be driven by the laser either in single-shot or in repetitive mode of operation. With the help of this unit, a video system is built for the capture of pulsed laser beam profiles and fluorescence traces of a picosecond autocorrelator. It is an inexpensive and more readily available alternative to commercial asynchronous video systems.

  3. Improvement and optimal design of RGB LED backlight unit using a genetic algorithm

    Science.gov (United States)

    Fan, Yi-Hua; Lee, Ying-Tsun; Liao, Yi-Lin; Fu, Chung-Chin

    2010-08-01

    To reduce the cost of LCD backlight unit (BLU) and raise efficiency, a direct LED BLU consisted of double-triangular structures was proposed to control the light from RGB side emitting LEDs. A genetic algorithm was used to search the optimal parameters of the shape of the double-triangular structures and the layout of the LEDs. A switch mode constant current control driver with a PWM controlled converter switch was used to maintaining the constant current output for the variable numbers of the LEDs in this paper. From the simulation results showed that without the diffuser, the brightness uniformity on the 25-point test was 93.44% for a 22" direct LED backlight unit with a thickness of 30mm with the optimized double-triangular structure. And the experiment result showed that the brightness uniformity and color uniformity were 85.61% and 0.021 for a small size test unit.

  4. 48 CFR 3036.104-90 - Authority for one-step turn-key design-build contracting for the United States Coast Guard (USCG).

    Science.gov (United States)

    2010-10-01

    ... turn-key design-build contracting for the United States Coast Guard (USCG). 3036.104-90 Section 3036... ACQUISITION REGULATION (HSAR) SPECIAL CATEGORIES OF CONTRACTING CONSTRUCTION AND ARCHITECT-ENGINEER CONTRACTS General 3036.104-90 Authority for one-step turn-key design-build contracting for the United States...

  5. Design trends for Army/Air Force airplanes in the United States

    Science.gov (United States)

    Spearman, M. Leroy

    1990-01-01

    Some design trends in Army/Air Force airplane systems in the U.S. are traced from the pre-World War 2 era to the present time. Various types of aircraft systems are reviewed with a view toward noting design features that were used. Some observations concerning the design trends indicate that some may be driven by advanced technology and some by a need for new mission requirements. In addition, it is noted that some design trends are evolutionary and result in an extension of service life or utility of existing systems. In other cases the design trends may be more revolutionary with the intent of creating a system with a new capability. Some examples are included of designs that did not proceed to production for reasons that sometimes were technical and sometimes were not.

  6. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). As-Designed Parts List: Electrical, Electronic and Electromechanical (EEE) As-Designed Parts List

    Science.gov (United States)

    Lorenz, E.

    1999-01-01

    This report comprises the Electrical, Electronic, and Electromechanical (EEE) As Designed Parts List to be used in the Integrated Advanced Microwave Sounding Unit-A (AMSU-A) instrument. The purpose of the EEE As-Designed Parts List is to provide a listing of EEE parts identified for use on the Integrated AMSU-A. All EEE parts used on the AMSU-A must meet the parts control requirements as defined in the Parts Control Plan (POP). All part applications are reviewed by the Parts Control Board (PCB) and granted approval if POP requirements are met. The "As Designed Parts Lists" indicates PCB approval status, and thus also serves as the Program Approved Parts List.

  7. Design of the IBM RISC System/6000 floating-point execution unit

    Energy Technology Data Exchange (ETDEWEB)

    Montoye, R.K.; Hokenek, E. (International Business Machines Corp., Yorktown Heights, NY (USA). Thomas J. Watson Research Center); Runyon, S.L. (IBM Advanced Workstations Div., Austin, TX (US))

    1990-01-01

    The IBM RISC System/6000 (RS/6000) floating-point unit (FPU) exemplifies a second-generation RISC CPU architecture and an implementation which greatly increases floating-point performance and accuracy. The key feature of the FPU is a unified floating-point multiply-add-fused unit (MAF) which performs the accumulate operation ({ital A} {times} {ital B}) + {ital C} as an indivisible operation. This single functional unit reduces the latency for chained floating-point operations, as well as rounding errors and chip busing. It also reduces the number of adders/normalizers by combining the addition required for fast multiplication with accumulation. The MAF unit is made practical by a unique fast-shifter, which eases the overlap of multiplication and addition, and a leading-zero/one anticipator, which eases overlap of normalization and addition. The accumulate instruction required by this architecture reduces the instruction path length by combining two instructions into one. Additionally, the RS/6000 FPU is tightly coupled to the rest of the CPU, unlike typical floating-point coprocessor chips.

  8. Website Interface Design: Similarity and Differences between Saudi Arabian and United States University Websites

    Science.gov (United States)

    Alyahya, Dalia Mohammed

    2011-01-01

    The expansion of the Internet and online learning around the globe makes it more important to understand the differences in website design among cultures. Furthermore, the members of educational institutions around the world rely on the Internet more than ever before in a variety of aspects. Also, web design differs from culture to culture. Saudi…

  9. Website Interface Design: Similarity and Differences between Saudi Arabian and United States University Websites

    Science.gov (United States)

    Alyahya, Dalia Mohammed

    2011-01-01

    The expansion of the Internet and online learning around the globe makes it more important to understand the differences in website design among cultures. Furthermore, the members of educational institutions around the world rely on the Internet more than ever before in a variety of aspects. Also, web design differs from culture to culture. Saudi…

  10. Addressing Diversity in an Early Years Mathematics Unit: A Matter of Design

    Science.gov (United States)

    Burrows, Peter

    2010-01-01

    In this article the manifold aims and theorised benefits of Learning by Design are explored and evaluated through the practices and experiences of an early years mathematics teacher. The article examines and elaborates the ways in which this teacher took up and embraced Learning by Design as both a professional meta-language and as a design…

  11. Micro Computer Technician Course. Course Design, Course Curricula, Learning Units, Resource Requirements. InfoTVE 14.

    Science.gov (United States)

    Royal Melbourne Inst. of Tech. (Australia).

    This guide to the core curricula for the training of microcomputer technicians is designed for school leavers after 10 or more years of general/vocational education with a science and mathematics background. The 2-year course is to be administered in four semesters. An introductory outline of course design and curricula provides the rationale,…

  12. Vancomycin-resistant enterococcus outbreak in a pediatric intensive care unit: report of successful interventions for control and prevention

    Directory of Open Access Journals (Sweden)

    F. Carmona

    2012-02-01

    Full Text Available The objective of this study is to retrospectively report the results of interventions for controlling a vancomycin-resistant enterococcus (VRE outbreak in a tertiary-care pediatric intensive care unit (PICU of a University Hospital. After identification of the outbreak, interventions were made at the following levels: patient care, microbiological surveillance, and medical and nursing staff training. Data were collected from computer-based databases and from the electronic prescription system. Vancomycin use progressively increased after March 2008, peaking in August 2009. Five cases of VRE infection were identified, with 3 deaths. After the interventions, we noted a significant reduction in vancomycin prescription and use (75% reduction, and the last case of VRE infection was identified 4 months later. The survivors remained colonized until hospital discharge. After interventions there was a transient increase in PICU length-of-stay and mortality. Since then, the use of vancomycin has remained relatively constant and strict, no other cases of VRE infection or colonization have been identified and length-of-stay and mortality returned to baseline. In conclusion, we showed that a bundle intervention aiming at a strict control of vancomycin use and full compliance with the Hospital Infection Control Practices Advisory Committee guidelines, along with contact precautions and hand-hygiene promotion, can be effective in reducing vancomycin use and the emergence and spread of vancomycin-resistant bacteria in a tertiary-care PICU.

  13. Accounting for medical communication: parents' perceptions of communicative roles and responsibilities in the pediatric intensive care unit.

    Science.gov (United States)

    Gordon, Cynthia; Barton, Ellen; Meert, Kathleen L; Eggly, Susan; Pollacks, Murray; Zimmerman, Jerry; Anand, K J S; Carcillo, Joseph; Newth, Christopher J L; Dean, J Michael; Willson, Douglas F; Nicholson, Carol

    2009-01-01

    Through discourse analysis of transcribed interviews conducted over the phone with parents whose child died in the Pediatric Intensive Care Unit (PICU) (n = 51), this study uncovers parents' perceptions of clinicians' and their own communicative roles and responsibilities in the context of team-based care. We examine parents' descriptions and narratives of communicative experiences they had with PICU clinicians, focusing on how parents use accounts to evaluate the communicative behaviors they report (n = 47). Findings indicate that parental perceptions of communicative responsibilities are more nuanced than assumed in previous research: Parents identified their own responsibilities as participating as part of the team of care, gathering information, interacting with appropriate affect, and working to understand complex and uncertain medical information. Complementarily, parents identified clinician responsibilities as communicating professionally, providing medical information clearly, managing parents' hope responsibly, and communicating with appropriate affect. Through the accounts they provide, parents evaluate both parental and clinician role-responsibilities as fulfilled and unfulfilled. Clinicians' management of prognostic uncertainty and parents' struggles to understand that uncertainty emerged as key, complementary themes with practical implications for incorporating parents into the PICU care team. The study also highlights insights retrospective interview data bring to the examination of medical communication.

  14. Engineering aspects and hardware verification of a volume producable solid oxide fuel cell stack design for diesel auxiliary power units

    Science.gov (United States)

    Stelter, Michael; Reinert, Andreas; Mai, Björn Erik; Kuznecov, Mihail

    A solid oxide fuel cell (SOFC) stack module is presented that is designed for operation on diesel reformate in an auxiliary power unit (APU). The stack was designed using a top-down approach, based on a specification of an APU system that is installed on board of vehicles. The stack design is planar, modular and scalable with stamped sheet metal interconnectors. It features thin membrane electrode assemblies (MEAs), such as electrolyte supported cells (ESC) and operates at elevated temperatures around 800 °C. The stack has a low pressure drop in both the anode and the cathode to facilitate a simple system layout. An overview of the technical targets met so far is given. A stack power density of 0.2 kW l -1 has been demonstrated in a fully integrated, thermally self-sustaining APU prototype running with diesel and without an external water supply.

  15. Challenges in designing a national surveillance program for inflammatory bowel disease in the United States.

    Science.gov (United States)

    Long, Millie D; Hutfless, Susan; Kappelman, Michael D; Khalili, Hamed; Kaplan, Gilaad G; Bernstein, Charles N; Colombel, Jean Frederic; Gower-Rousseau, Corinne; Herrinton, Lisa; Velayos, Fernando; Loftus, Edward V; Nguyen, Geoffrey C; Ananthakrishnan, Ashwin N; Sonnenberg, Amnon; Chan, Andrew; Sandler, Robert S; Atreja, Ashish; Shah, Samir A; Rothman, Kenneth J; Leleiko, Neal S; Bright, Renee; Boffetta, Paolo; Myers, Kelly D; Sands, Bruce E

    2014-02-01

    This review describes the history of U.S. government funding for surveillance programs in inflammatory bowel diseases (IBD), provides current estimates of the incidence and prevalence of IBD in the United States, and enumerates a number of challenges faced by current and future IBD surveillance programs. A rationale for expanding the focus of IBD surveillance beyond counts of incidence and prevalence, to provide a greater understanding of the burden of IBD, disease etiology, and pathogenesis, is provided. Lessons learned from other countries are summarized, in addition to potential resources that may be used to optimize a new form of IBD surveillance in the United States. A consensus recommendation on the goals and available resources for a new model for disease surveillance are provided. This new model should focus on "surveillance of the burden of disease," including (1) natural history of disease and (2) outcomes and complications of the disease and/or treatments.

  16. Computational design of metal-organic frameworks with paddlewheel-type secondary building units

    Science.gov (United States)

    Schwingenschlogl, Udo; Peskov, Maxim V.; Masghouni, Nejib

    We employ the TOPOS package to study 697 coordination polymers containing paddlewheel-type secondary building units. The underlying nets are analyzed and 3 novel nets are chosen as potential topologies for paddlewheel-type metal organic frameworks (MOFs). Dicarboxylate linkers are used to build basic structures for novel isoreticular MOF series, aiming at relatively compact structures with a low number of atoms per unit cell. The structures are optimized using density functional theory. Afterwards the Grand Canonical Monte Carlo approach is employed to generate adsorption isotherms for CO2, CO, and CH4 molecules. We utilize the universal forcefield for simulating the interaction between the molecules and hosting MOF. The diffusion behavior of the molecules inside the MOFs is analyzed by molecular dynamics simulations.

  17. A DNA Crystal Designed to Contain Two Molecules per Asymmetric Unit

    Energy Technology Data Exchange (ETDEWEB)

    T Wang; R Sha; J Birktoft; J Zheng; C Mao; N Seeman

    2011-12-31

    We describe the self-assembly of a DNA crystal that contains two tensegrity triangle molecules per asymmetric unit. We have used X-ray crystallography to determine its crystal structure. In addition, we have demonstrated control over the colors of the crystals by attaching either Cy3 dye (pink) or Cy5 dye (blue-green) to the components of the crystal, yielding crystals of corresponding colors. Attaching the pair of dyes to the pair of molecules yields a purple crystal.

  18. Design of a Floating-Point Fused Add-Subtract Unit Using Verilog

    Directory of Open Access Journals (Sweden)

    Mayank Sharma,

    2013-06-01

    Full Text Available A floating-point (FP fused add-subtract unit is presented that performs simultaneous floating-point operation of add-subtract on a common pair of single-precision data at the same time that it takes to perform in a single addition with a conventional floating-point adder. The system was placed and routed in 45nm process so that there will be less consumption of memory as well as power.

  19. Conceptual design of the X-IFU Instrument Control Unit on board the ESA Athena mission

    Science.gov (United States)

    Corcione, L.; Ligori, S.; Capobianco, V.; Bonino, D.; Valenziano, L.; Guizzo, G. P.

    2016-07-01

    Athena is one of L-class missions selected in the ESA Cosmic Vision 2015-2025 program for the science theme of the Hot and Energetic Universe. The Athena model payload includes the X-ray Integral Field Unit (X-IFU), an advanced actively shielded X-ray microcalorimeter spectrometer for high spectral resolution imaging, utilizing cooled Transition Edge Sensors. This paper describes the preliminary architecture of Instrument Control Unit (ICU), which is aimed at operating all XIFU's subsystems, as well as at implementing the main functional interfaces of the instrument with the S/C control unit. The ICU functions include the TC/TM management with S/C, science data formatting and transmission to S/C Mass Memory, housekeeping data handling, time distribution for synchronous operations and the management of the X-IFU components (i.e. CryoCoolers, Filter Wheel, Detector Readout Electronics Event Processor, Power Distribution Unit). ICU functions baseline implementation for the phase-A study foresees the usage of standard and Space-qualified components from the heritage of past and current space missions (e.g. Gaia, Euclid), which currently encompasses Leon2/Leon3 based CPU board and standard Space-qualified interfaces for the exchange commands and data between ICU and X-IFU subsystems. Alternative architecture, arranged around a powerful PowerPC-based CPU, is also briefly presented, with the aim of endowing the system with enhanced hardware resources and processing power capability, for the handling of control and science data processing tasks not defined yet at this stage of the mission study.

  20. Bootloader with reprogramming functionality for electronic control units in vehicles: Analysis, design and Implementation

    OpenAIRE

    Pehrsson, David; Garza, Jesús

    2012-01-01

    In an automotive context today’s need of testing functions while in factory, correcting faults in the workshop or adding extra value in the aftermarket makes it very important to easily be able to download new software to the electronic control units in vehicles. In the platform for standard automotive software development called AUTOSAR, two known protocols are presented to specify the procedure on how to implement this download operation: Unified Diagnostic Services (UDS) and the Universal ...

  1. Critical Habitat Designations in the United States as of January 2016.

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Endangered Species Act (ESA) requires the Federal government to designate "critical habitat" for any ESA listed species. This dataset is a compilation of the...

  2. Design of an Innovative Information System for the Intensive Care Unit in a Public Hospital.

    Science.gov (United States)

    Tsoromokos, Dimitrios; Tsaloukidis, Nikolaos; Dermatis, Zacharias; Gozadinos, Filippos; Lazakidou, Athina

    2016-01-01

    The health sector is increasingly focused on the use of Communication Technology (ICT) Information and Communication. New technologies which introduced in health, should lead to lower cost of procedures, saving employees' working time and immediate and secure data storages for easy future search or meta-analysis. The DPP4ICU application which presented in this document, allows at the Intensive Care Unit's nurses (ICU) to enter directly the handwritten accountability, in the Organization Information System. Through this application is accelerated the proper completion of a document and is improved data quality. The application provides the ability to authorized users to exchange information with an automated manner.

  3. Avionics system design for requirements for the United States Coast Guard HH-65A Dolphin

    Science.gov (United States)

    Young, D. A.

    1984-01-01

    Aerospatiale Helicopter Corporation (AHC) was awarded a contract by the United States Coast Guard for a new Short Range Recovery (SRR) Helicopter on 14 June 1979. The award was based upon an overall evaluation of performance, cost, and technical suitability. In this last respect, the SRR helicopter was required to meet a wide variety of mission needs for which the integrated avionics system has a high importance. This paper illustrates the rationale for the avionics system requirements, the system architecture, its capabilities and reliability and its adaptability to a wide variety of military and commercial purposes.

  4. Design, Fabrication and Test of an Integrated Built-In-Test (BIT) Control Unit.

    Science.gov (United States)

    1982-10-01

    II 00 00 Im 0. N 0x tot ui 0 J~f C * 0 a I CL c. .4 cL’ U)J 00 in8 Three cables provide the interface between the B17 control unit and the power...5. Replace module and test again. Line 6. Blank STO ,I S On A-8 I Sample pin P36 wit nounce:ctr. Lin 4.A Blankv Ye No Most NegativeYe L n 3 Fault in

  5. Coverage Range and Cost Comparison of Remote Antenna Unit Designs for Inbuilding Radio over Fiber Technology

    Directory of Open Access Journals (Sweden)

    Razali Ngah

    2013-09-01

    Full Text Available Future communication needs to be ubiquitous, broadband, convergent, and seamless. Radio over fiber (RoF technology is one of the most important enabler in access network for the technologies. Adoption of RoF faces bottleneck in optoelectronics, that they are still expensive, high power consumption, and limited in bandwidth. To solve the problem, transceiver in remote antenna unit (RAU is developed, i.e. electroabsorption transceiver (EAT and asymmetric FabryPerot modulator (AFPM. This paper compares their coverage range and cost in providing WCDMA and WLAN services. Needed gain of RF amplifier for supporting picocell is also discussed.

  6. Planning, Designing, Building, and Moving a Large Volume Maternity Service to a New Labor and Birth Unit.

    Science.gov (United States)

    Thompson, Heather; Legorreta, Kimberly; Maher, Mary Ann; Lavin, Melanie M

    Our health system recognized the need to update facility space and associated technology for the labor and birth unit within our large volume perinatal service to improve the patient experience, and enhance safety, quality of care, and staff satisfaction. When an organization decides to invest $30 million dollars in a construction project such as a new labor and birth unit, many factors and considerations are involved. Financial support, planning, design, and construction phases of building a new unit are complex and therefore require strong interdisciplinary collaboration, leadership, and project management. The new labor and birth unit required nearly 3 years of planning, designing, and construction. Patient and family preferences were elicited through consumer focus groups. Multiple meetings with the administrative and nursing leadership teams, staff nurses, nurse midwives, and physicians were held to generate ideas for improvement in the new space. Involving frontline clinicians and childbearing women in the process was critical to success. The labor and birth unit moved to a new patient tower in a space that was doubled in square footage and geographically now on three separate floors. In the 6 months prior to the move, many efforts were made in our community to share our new space. The marketing strategy was very detailed and creative with ongoing input from the nursing leadership team. The nursing staff was involved in every step along the way. It was critical to have champions as workflow teams emerged. We hosted simulation drills and tested scenarios with new workflows. Move day was rehearsed with representatives of all members of the perinatal team participating. These efforts ultimately resulted in a move time of ~5 hours. Birth volumes increased 7% within the first 6 months. After 3 years in our new space, our birth volumes have risen nearly 15% and are still growing. Key processes and roles responsible for a successful build, efficient and safe move

  7. Design, Synthesis, Activity and Docking Study of Sorafenib Analogs Bearing Sulfonylurea Unit.

    Science.gov (United States)

    Wu, Chunjiang; Wang, Min; Tang, Qidong; Luo, Rong; Chen, Le; Zheng, Pengwu; Zhu, Wufu

    2015-10-23

    Two series of novel sorafenib analogs containing a sulfonylurea unit were synthesized and their chemical structures were confirmed by ¹H-NMR, ¹³C-NMR, MS spectrum and elemental analysis. The synthesized compounds were evaluated for the cytotoxicity against A549, Hela, MCF-7, and PC-3 cancer cell lines. Some of the compounds showed moderate cytotoxic activity, especially compounds 1-(2,4-difluorophenylsulfonyl)-3-(4-(2-(methylcarbamoyl)pyridin-4-yloxy)phenyl)urea (6c) and 1-(4-bromophenylsulfonyl)-3-(4-(2-(methylcarbamoyl)pyridin-4-yloxy)phenyl)urea (6f) with the IC50 values against four cancer cell lines ranging from 16.54±1.22 to 63.92±1.81 μM, respectively. Inhibitory rates against vascular endothelial growth factor receptor-2 (VEGFR2/KDR) kinase at 10 μM of target compounds were further carried out in this paper in order to investigate the target of these compounds. Structure-activity relationships (SARs) and docking studies indicated that the sulfonylurea unit was important to these kinds of compounds. None of the substitutions in the phenoxy group and small halogen atoms such as 2,4-difluoro substitution of the aryl group contributed to the activity. The results suggested that sulfonylurea sorafenib analogs are worthy of further study.

  8. Design and Test Plans for a Non-Nuclear Fission Power System Technology Demonstration Unit

    Science.gov (United States)

    Mason, Lee; Palac, Donald; Gibson, Marc; Houts, Michael; Warren, John; Werner, James; Poston, David; Qualls, Arthur Lou; Radel, Ross; Harlow, Scott

    2012-01-01

    A joint National Aeronautics and Space Administration (NASA) and Department of Energy (DOE) team is developing concepts and technologies for affordable nuclear Fission Power Systems (FPSs) to support future exploration missions. A key deliverable is the Technology Demonstration Unit (TDU). The TDU will assemble the major elements of a notional FPS with a non-nuclear reactor simulator (Rx Sim) and demonstrate system-level performance in thermal vacuum. The Rx Sim includes an electrical resistance heat source and a liquid metal heat transport loop that simulates the reactor thermal interface and expected dynamic response. A power conversion unit (PCU) generates electric power utilizing the liquid metal heat source and rejects waste heat to a heat rejection system (HRS). The HRS includes a pumped water heat removal loop coupled to radiator panels suspended in the thermal-vacuum facility. The basic test plan is to subject the system to realistic operating conditions and gather data to evaluate performance sensitivity, control stability, and response characteristics. Upon completion of the testing, the technology is expected to satisfy the requirements for Technology Readiness Level 6 (System Demonstration in an Operational and Relevant Environment) based on the use of high-fidelity hardware and prototypic software tested under realistic conditions and correlated with analytical predictions.

  9. Theoretical characterization and design of small molecule donor material containing naphthodithiophene central unit for efficient organic solar cells.

    Science.gov (United States)

    Duan, Yu-Ai; Geng, Yun; Li, Hai-Bin; Jin, Jun-Ling; Wu, Yong; Su, Zhong-Min

    2013-07-15

    To seek for high-performance small molecule donor materials used in heterojunction solar cell, six acceptor-donor-acceptor small molecules based on naphtho[2,3-b:6,7-b']dithiophene (NDT) units with different acceptor units were designed and characterized using density functional theory and time-dependent density functional theory. Their geometries, electronic structures, photophysical, and charge transport properties have been scrutinized comparing with the reported donor material NDT(TDPP)2 (TDPP  =  thiophene-capped diketopyrrolopyrrole). The open circuit voltage (V(oc)), energetic driving force(ΔE(L-L)), and exciton binding energy (E(b)) were also provided to give an elementary understanding on their cell performance. The results reveal that the frontier molecular orbitals of 3-7 match well with the acceptor material PC61 BM, and compounds 3-5 were found to exhibit the comparable performances to 1 and show promising potential in organic solar cells. In particular, comparing with 1, system 7 with naphthobisthiadiazole acceptor unit displays broader absorption spectrum, higher V(oc), lower E(b), and similar carrier mobility. An in-depth insight into the nature of the involved excited states based on transition density matrix and charge density difference indicates that all S1 states are mainly intramolecular charge transfer states with the charge transfer from central NDT unit to bilateral acceptor units, and also imply that the exciton of 7 can be dissociated easily due to its large extent of the charge transfer. In a word, 7 maybe superior to 1 and may act as a promising donor candidate for organic solar cell. Copyright © 2013 Wiley Periodicals, Inc.

  10. Teachers Collaborate across State Lines to Design High-Quality Units

    Science.gov (United States)

    Vasudeva, Ash; Slamp, Amy

    2016-01-01

    With states and districts across the country implementing the Common Core State Standards, teachers have more opportunities than ever to collaborate around the shared goals of strengthening curriculum design, classroom practices, and student learning. Building from this premise, the Common Assignment Study (CAS) has brought together teams of…

  11. The Politics of Curriculum and Instructional Design/Theory/Form: Critical Problems, Projects, Units, and Modules

    Science.gov (United States)

    Petrina, Stephen

    2004-01-01

    What should be learned? How should it be organized for teaching? These seemingly simple questions are deceivingly political. Curriculum theorists are preoccupied with the politics of the first question at the expense of the realpolitik of the second. Instructional designers are preoccupied with the realpolitik of the second question at the expense…

  12. Light-Switchable Peptides with a Hemithioindigo Unit : Peptide Design, Photochromism, and Optical Spectroscopy

    NARCIS (Netherlands)

    Kitzig, S.; Thilemann, M.; Cordes, T.; Rueck-Braun, Karola

    2016-01-01

    This Minireview focuses on the hemithioindigo photoswitch and its use for the reversible control of three-dimensional peptide structure and related biological functions. Both the general design aspects and biophysical properties of various hemithioindigo-based chromopeptides are summarized. Hemithio

  13. Design of an Integrated Sensor Platform for Vital Sign Monitoring of Newborn Infants at Neonatal Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2010-01-01

    Full Text Available Continuous health status monitoring and advances in medical treatments have resulted in a significant increase of survival rate in critically ill infants admitted into Neonatal Intensive Care Units (NICUs. The quality of life and long-term health prospects of the neonates depend increasingly on the reliability and comfort of the monitoring systems. In this paper, we present the design work of a smart jacket for vital sign monitoring of neonates at a NICU. The design represents a unique integration of sensor technology, user focus and design aspects. Textile sensors, a reflectance pulse oximeter and a wearable temperature sensor were proposed to be embedded into the smart jacket. Location of the sensor, materials and appearance were designed to optimize the functionality, patient comfort and the possibilities for aesthetic features. Prototypes were built for demonstrating the design concept and experimental results were obtained from tests on premature babies at the NICU of M�xima Medical Centre (MMC in Veldhoven, the Netherlands.

  14. Analysis, design, fabrication and testing of the mini-Brayton rotating unit (Mini-BRU). Volume 1: Text and tables

    Science.gov (United States)

    Dobler, F. X.

    1978-01-01

    A 500 to 2100 watt power output Mini-Brayton Rotating Unit (Mini-BRU)was analyzed, designed, fabricated and tested. Performance and test data for the various components is included. Components tested include the 2.12 in. diameter compressor, the 2.86 in. diameter turbine, the Rice alternator and the cantilevered foil-type journal and thrust bearings. Also included are results on the fabrication of a C-103 turbine plenum/nozzle assembly and on offgassing of the organic materials in the alternator stator.

  15. Design and Investigation of Photonic Remote Antenna Units for Bidirectional Transmission in the Last Mile Wireless over Fiber System

    Directory of Open Access Journals (Sweden)

    A. Łysiuk

    2013-12-01

    Full Text Available In the article three different photonic Remote Antenna Units (RAU in the last mile Wireless over Fiber links are presented. For construction of RAU commercially available optoelectronic devices were used. The solutions differ from each other by the method of ensuring isolation between transmitting and receiving modes of operation. All RAUs were designed, realized and measured in various scenarios. The results prove that all propositions can be successfully applied to uplink and downlink IEEE 802.11b/g wireless LAN systems, employing Wireless over Fiber technique.

  16. A Comprehensive Design Approach of Power Electronic-Based Distributed Generation Units Focused on Power Quality Improvement

    DEFF Research Database (Denmark)

    Esparza, Miguel; Segundo-Ramirez, Juan; Nunez, Ciro

    2017-01-01

    The undesirable harmonic distortion produced by distributed generation units (DGUs) based on power electronic inverters presents operating and power quality challenges in electric systems. ‡e level of distortion depends on the internal elements of the DGUs as well as on the characteristics...... of the grid, loads, controls, among others. ‡is paper presents a comprehensive method, focused on power quality indexes and e�ciency for the design of micro-grids with multiple DGUs interconnected to the AC grid through three phase multi-Megawatt medium-voltage PWM voltage source inverters (PWM-VSI). ‡e...

  17. Low-power and Low-cost Design of Survival Memory Unit for 1000Base-T Gigabit Ethernet Transceiver

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Types of hybrid architectures survivor memory unit (SMU) is presented,which are applicable to IEEE 802.3 ab 1000 Base-T Gigabit Ethernet (GbE) transceiver. Area, power and decoder latency were taken into account and most efficient architectures were compared to optimize area/power tradeoff in different kinds of applications. Suitable SMU architectures are given out respectively in area-restrict, power-restrict and latency-restrict designs. A power-efficient architecture was selected in our GbE project. It provides 48% improvement in area and 71% amelioration in power, compared to classical register exchange architecture (REA) SMU.

  18. Risk-Targeted versus Current Seismic Design Maps for the Conterminous United States

    Science.gov (United States)

    Luco, Nicolas; Ellingwood, Bruce R.; Hamburger, Ronald O.; Hooper, John D.; Kimball, Jeffrey K.; Kircher, Charles A.

    2007-01-01

    The probabilistic portions of the seismic design maps in the NEHRP Provisions (FEMA, 2003/2000/1997), and in the International Building Code (ICC, 2006/2003/2000) and ASCE Standard 7-05 (ASCE, 2005a), provide ground motion values from the USGS that have a 2% probability of being exceeded in 50 years. Under the assumption that the capacity against collapse of structures designed for these "uniformhazard" ground motions is equal to, without uncertainty, the corresponding mapped value at the location of the structure, the probability of its collapse in 50 years is also uniform. This is not the case however, when it is recognized that there is, in fact, uncertainty in the structural capacity. In that case, siteto-site variability in the shape of ground motion hazard curves results in a lack of uniformity. This paper explains the basis for proposed adjustments to the uniform-hazard portions of the seismic design maps currently in the NEHRP Provisions that result in uniform estimated collapse probability. For seismic design of nuclear facilities, analogous but specialized adjustments have recently been defined in ASCE Standard 43-05 (ASCE, 2005b). In support of the 2009 update of the NEHRP Provisions currently being conducted by the Building Seismic Safety Council (BSSC), herein we provide examples of the adjusted ground motions for a selected target collapse probability (or target risk). Relative to the probabilistic MCE ground motions currently in the NEHRP Provisions, the risk-targeted ground motions for design are smaller (by as much as about 30%) in the New Madrid Seismic Zone, near Charleston, South Carolina, and in the coastal region of Oregon, with relatively little (<15%) change almost everywhere else in the conterminous U.S.

  19. Optimal control system design of an acid gas removal unit for an IGCC power plants with CO2 capture

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D.; Bhattacharyya, D.; Turton, R.; Zitney, S.

    2012-01-01

    Future IGCC plants with CO{sub 2} capture should be operated optimally in the face of disturbances without violating operational and environmental constraints. To achieve this goal, a systematic approach is taken in this work to design the control system of a selective, dual-stage Selexol-based acid gas removal (AGR) unit for a commercial-scale integrated gasification combined cycle (IGCC) power plant with pre-combustion CO{sub 2} capture. The control system design is performed in two stages with the objective of minimizing the auxiliary power while satisfying operational and environmental constraints in the presence of measured and unmeasured disturbances. In the first stage of the control system design, a top-down analysis is used to analyze degrees of freedom, define an operational objective, identify important disturbances and operational/environmental constraints, and select the control variables. With the degrees of freedom, the process is optimized with relation to the operational objective at nominal operation as well as under the disturbances identified. Operational and environmental constraints active at all operations are chosen as control variables. From the results of the optimization studies, self-optimizing control variables are identified for further examination. Several methods are explored in this work for the selection of these self-optimizing control variables. Modifications made to the existing methods will be discussed in this presentation. Due to the very large number of candidate sets available for control variables and due to the complexity of the underlying optimization problem, solution of this problem is computationally expensive. For reducing the computation time, parallel computing is performed using the Distributed Computing Server (DCS®) and the Parallel Computing® toolbox from Mathworks®. The second stage is a bottom-up design of the control layers used for the operation of the process. First, the regulatory control layer is

  20. THE EVOLUTION OF THE DESIGN AND CONSTRUCTION OF MASONRY BUILDINGS IN THE UNITED STATES

    Directory of Open Access Journals (Sweden)

    Richard E. Klingner

    2012-12-01

    Full Text Available In this paper, the process used to develop building codes in the United States of America (USA is summarized, with emphasis on masonry. Masonry materials used in the USA are discussed. Types of masonry construction in the USA are reviewed, addressing historical as well as modern masonry. Current non-structural and structural applications of masonry in the USA are reviewed. Historical development of masonry codes in the USA is summarized, with emphasis on the current Masonry Standards Joint Committee (MSJC Code and Specification. Future trends in that document are predicted. The paper closes with a list of challenges to the masonry industry, and a list of focused research topics intended to meet those challenges.

  1. Design of Central Management & Control Unit for Onboard High-Speed Data Handling System

    Institute of Scientific and Technical Information of China (English)

    LI Yan-qin; JIN Sheng-zhen; NING Shu-nian

    2007-01-01

    The Main Optical Telescope (MOT) is an important payload of the Space Solar Telescope (SST) with various instruments and observation modes. Its real-time data handling and management and control tasks are arduous. Based on the advanced techniques of foreign countries, an improved structure of onboard data handling systems feasible for SST, is proposed. This article concentrated on the development of a Central Management & Control Unit (MCU) based on FPGA and DSP. Through reconfigurating the FPGA and DSP programs, the prototype could perform different tasks.Thus the inheritability of the whole system is improved. The completed dual-channel prototype proves that the system meets all requirements of the MOT. Its high reliability and safety features also meet the requirements under harsh conditions such as mine detection.

  2. Implementing health care reform in the United States: intergovernmental politics and the dilemmas of institutional design.

    Science.gov (United States)

    Béland, Daniel; Rocco, Philip; Waddan, Alex

    2014-05-01

    The Affordable Care Act (ACA) was enacted, and continues to operate, under conditions of political polarization. In this article, we argue that the law's intergovernmental structure has amplified political conflict over its implementation by distributing governing authority to political actors at both levels of the American federal system. We review the ways in which the law's demands for institutional coordination between federal and state governments (and especially the role it preserves for governors and state legislatures) have created difficulties for rolling out health-insurance exchanges and expanding the Medicaid program. By way of contrast, we show how the institutional design of the ACA's regulatory reforms of the insurance market, which diminish the reform's political salience, has allowed for considerably less friction during the implementation process. This article thus highlights the implications of multi-level institutional designs for the post-enactment politics of major reforms.

  3. Testing the Organizational Assessment Model of Work Unit Design. A Systems Approach.

    Science.gov (United States)

    1985-02-01

    Tushman, 11. L. and D. A. Nadler 1978 "Information Processing as an Integrating Concept in Organizational Design," Academy of Management Review, 3: o13...Development, Test and Evaluacion Naval Air Station Pensacola, FL 32508 Chief of Naval Technical Training ATTN: Code D17 NAS Memphis (75) Millington, TN...Charles C. Man&, Kevin W. Mossholder, and Fred Luthans, "An integrated perspective of self-control in organization" (July 1984) (16) Robert P. King

  4. Seaweed raft and farm design in the United States and China

    Energy Technology Data Exchange (ETDEWEB)

    McKay, L.B.

    1983-01-01

    The following topics are discussed in this report: pilot-scale mariculture of seaweeds in Washington; experimental-scale raft culture of marine macroalgae in inland marine waters; macroalgal culture in California and China; land-based cultivation of seaweeds: an assessment of their potential yields for 'energy farming'; a design for energy-independent seaweed raft culture in tidal creeks and rivers; and the New York State marine biomass program.

  5. Automotive electronic control units: Inspection design considering time and resources constrains.

    OpenAIRE

    Solé Genescà, Aleix

    2017-01-01

    On this this document, the state of the art about engine management system inspection will be studied during design and prototyping phase. For this reason, a deep background on automotive sector is needed. Automotive history will be reviewed from the creation of first motorized car up to completely autonomous autopilot, created by Tesla. After that, future trends such as hardware and software modularization will be reviewed. Considering cars high complexity, it is important to have a clear me...

  6. Design and Analysis of Health Products and Services: An Example at a Specialized COPD Unit

    Science.gov (United States)

    Domingo, Christian; Rubio, Vicente Ortún

    2008-01-01

    Health care demands have increased dramatically in recent decades. With the introduction of major changes in the management of health problems, health care costs have spiralled. Today, in the interests of cost control, medicine is geared towards outpatient care whenever possible. In this process, the medical community has been obliged to adapt its traditional criteria to the dictates of national economies. Today the criteria for the organization and evaluation of the health services are based on the concepts of efficacy, effectiveness and efficiency. This has led to the emergence of a new discipline for the design and evaluation of medical service production, known as servuction, an amalgam of “service” and “production”. The organigram of a new health product should include the problems the program faces and the steps proposed to overcome these problems. The concept of evaluation can be divided into two categories: administrative evaluation, and evaluative research. Avedis Donabedian was one of the founders of evaluative research, based on an easy-to-remember triad: structure-process-results. In the final evaluation of a new health care model, the innovations it provides must be considered. In this article we describe the stages involved in the design of a new health product and correlate them with the types of evaluation that should be applied at each point in the process. Our discussion addresses general aspects of servuction, but also focuses on the design of a particular service, created to care for patients with severe COPD. PMID:19340319

  7. Banana Bark as A Part of Acoustic Design Unit by Hybrid Technology Application

    Directory of Open Access Journals (Sweden)

    Maharani Dian Permanasari

    2014-10-01

    Full Text Available Abstract. Banana bark is one of tropical indigenous natural resources that can be used as main material for many products. Being a fast-growing renewable material, it is durable and has natural patterns that people find visually attractive. Naturally, its textures and patterns are its main values; therefore it has the potential to be developed further. This research is needed to optimize the growth of small craft industries of banana bark, including the community where production activities take place, and also to provide information or reference of banana bark utilizations. Previous experiments conclude that banana bark has porous structure, high flexibility, relatively water-resistant due to its natural wax coating that resists water droplets, unless being washed down immensely. Also, due to its softwood- and paper-like properties, ithas many possibilities to be formed and processed into various functional products, mostly as craft products. In the subsequent study, the research about the utilization of banana bark in small industries starting from the harvesting system, handling problems in raw material supply, applying proper technology in improving the material’s quality, improving the human-resource working culture by appropriate technologies, and also innovating the product’s designs. The recommended designs can be implemented to improve the performance and qualities of banana bark products.Keywords: applied technology; banana bark; renewable materials; design; sustainability.

  8. Design and analysis of health products and services: An example at a specialized COPD unit.

    Science.gov (United States)

    Domingo, Christian; Rubio, Vicente Ortún

    2008-01-01

    Health care demands have increased dramatically in recent decades. With the introduction of major changes in the management of health problems, health care costs have spiralled. Today, in the interests of cost control, medicine is geared towards outpatient care whenever possible.In this process, the medical community has been obliged to adapt its traditional criteria to the dictates of national economies. Today the criteria for the organization and evaluation of the health services are based on the concepts of efficacy, effectiveness and efficiency. This has led to the emergence of a new discipline for the design and evaluation of medical service production, known as servuction, an amalgam of "service" and "production". The organigram of a new health product should include the problems the program faces and the steps proposed to overcome these problems. The concept of evaluation can be divided into two categories: administrative evaluation, and evaluative research. Avedis Donabedian was one of the founders of evaluative research, based on an easy-to-remember triad: structure-process-results. In the final evaluation of a new health care model, the innovations it provides must be considered.In this article we describe the stages involved in the design of a new health product and correlate them with the types of evaluation that should be applied at each point in the process. Our discussion addresses general aspects of servuction, but also focuses on the design of a particular service, created to care for patients with severe COPD.

  9. Design of FPGA based 32-bit Floating Point Arithmetic Unit and verification of its VHDL code using MATLAB

    Directory of Open Access Journals (Sweden)

    Naresh Grover

    2014-02-01

    Full Text Available Most of the algorithms implemented in FPGAs used to be fixed-point. Floating-point operations are useful for computations involving large dynamic range, but they require significantly more resources than integer operations. With the current trends in system requirements and available FPGAs, floating-point implementations are becoming more common and designers are increasingly taking advantage of FPGAs as a platform for floating-point implementations. The rapid advance in Field-Programmable Gate Array (FPGA technology makes such devices increasingly attractive for implementing floating-point arithmetic. Compared to Application Specific Integrated Circuits, FPGAs offer reduced development time and costs. Moreover, their flexibility enables field upgrade and adaptation of hardware to run-time conditions. A 32 bit floating point arithmetic unit with IEEE 754 Standard has been designed using VHDL code and all operations of addition, subtraction, multiplication and division are tested on Xilinx. Thereafter, Simulink model in MAT lab has been created for verification of VHDL code of that Floating Point Arithmetic Unit in Modelsim.

  10. Optical lenses design and experimental investigations of a dynamic focusing unit for a CO2 laser scanning system

    Science.gov (United States)

    Chen, Wei; Xu, Yue; Zhang, Huaxin; Liu, Peng; Jiao, Guohua

    2016-09-01

    Laser scanners are critical components in material processing systems, such as welding, cutting, and drilling. To achieve high-accuracy processing, the laser spot size should be small and uniform in the entire objective flat field. However, traditional static focusing method using F-theta objective lens is limited by the narrow flat field. To overcome these limitations, a dynamic focusing unit consisting of two lenses is presented in this paper. The dual-lens system has a movable plano-concave lens and a fixed convex lens. As the location of the movable optical elements is changed, the focal length is shifted to keep a small focus spot in a broad flat processing filed. The optical parameters of the two elements are theoretical analyzed. The spot size is calculated to obtain the relationship between the moving length of first lens and the shift focus length of the system. Also, the Zemax model of the optical system is built up to verify the theoretical design and optimize the optical parameter. The proposed lenses are manufactured and a test system is built up to investigate their performances. The experimental results show the spot size is smaller than 450um in all the 500*500mm 2 filed with CO2 laser. Compared with the other dynamic focusing units, this design has fewer lenses and no focusing spot in the optical path. In addition, the focal length minimal changes with the shit of incident laser beam.

  11. The optimal parameter design for a welding unit of manufacturing industry by Taguchi method and computer simulation

    Directory of Open Access Journals (Sweden)

    Seyed Mojib Zahraee

    2016-05-01

    Full Text Available Purpose: Manufacturing systems include a complicated combination of resources, such as materials, labors, and machines. Hence, when the manufacturing systems are faced with a problem related to the availability of resources it is difficult to identify the root of the problem accurately and effectively. Managers and engineers in companies are trying to achieve a robust production line based on the maximum productivity. The main goal of this paper is to design a robust production line, taking productivity into account in the selected manufacturing industry. Design/methodology/approach: This paper presents the application of Taguchi method along with computer simulation for finding an optimum factor setting for three controllable factors, which are a number of welding machines, hydraulic machines, and cutting machines by analyzing the effect of noise factors in a selected manufacturing industry. Findings and Originality/value: Based on the final results, the optimal design parameter of welding unit of in the selected manufacturing industry will be obtained when factor A is located at level 2 and B and C are located at level 1. Therefore, maximum productive desirability is achieved when the number of welding machines, hydraulic machines, and cutting machines is equal to 17, 2, and 1, respectively. This paper has a significant role in designing a robust production line by considering the lowest cost and timely manner based on the Taguchi method.

  12. Combining Latin Hypercube Designs and Discrete Event Simulation in a Study of a Surgical Unit

    DEFF Research Database (Denmark)

    Dehlendorff, Christian; Andersen, Klaus Kaae; Kulahci, Murat

    Summary form given only:In this article experiments on a discrete event simulation model for an orthopedic surgery are considered. The model is developed as part of a larger project in co-operation with Copenhagen University Hospital in Gentofte. Experiments on the model are performed by using...... Latin hypercube designs. The parameter set consists of system settings such as use of preparation room for sedation and the number of operating rooms, as well as management decisions such as staffing, size of the recovery room and the number of simultaneously active operating rooms. Sensitivity analysis...

  13. Changes in Instructional System Design (ISD): Improving Training Product Delivery to United States Army Soldiers

    Science.gov (United States)

    2005-03-18

    Ulcers Tumors Gastritis Diseases Digestion Role of Teeth in Digestion Digestion in Mouth Role of Tongue in Digestion Role of Saliva Glands in...Design and the Addie Model e-Learning Guru.com,” 2003; available from <http://www.e-learningguru.com/ articles /art2_1.htm. P.2>; Internet; accessed 4...Model. e-Learning Guru.com,” 2003. Available from <http://www.e-learningguru.com/ articles /art2_1.htm>. Internet. Accessed 4 December 2004. Lakein

  14. Design, Fabrication, and Testing of a Bulk Micromachined Inertial Measurement Unit

    Directory of Open Access Journals (Sweden)

    Honglong Chang

    2010-04-01

    Full Text Available A bulk micromachined inertial measurement unit (MIMU is presented in this paper. Three single-axis accelerometers and three single-axis gyroscopes were simultaneously fabricated on a silicon wafer using a bulk micromachining process; the wafer is smaller than one square centimeter. In particular, a global area optimization method based on the relationship between the sensitivity and layout area was proposed to determine the layout configuration of the six sensors. The scale factors of the X/Y-axis accelerometer and Z-axis accelerometer are about 213.3 mV/g and 226.9 mV/g, respectively. The scale factors of the X/Y-axis gyroscope and Z-axis gyroscope are about 2.2 mV/o/s and 10.8 mV/o/s, respectively. The bias stability of the X/Y-axis gyroscope and the Z-axis gyroscope are about 2135 deg/h and 80 deg/h, respectively. Finally, the resolutions of X/Y-axis accelerometers, Z-axis accelerometers, X/Y-axis gyroscopes, and Z-axis gyroscopes are 0.0012 g/ √Hz, 0.0011 g/ √Hz, 0.314 °/s/ √Hz, and 0.008 °/s/ √Hz, respectively.

  15. Parallel design of JPEG-LS encoder on graphics processing units

    Science.gov (United States)

    Duan, Hao; Fang, Yong; Huang, Bormin

    2012-01-01

    With recent technical advances in graphic processing units (GPUs), GPUs have outperformed CPUs in terms of compute capability and memory bandwidth. Many successful GPU applications to high performance computing have been reported. JPEG-LS is an ISO/IEC standard for lossless image compression which utilizes adaptive context modeling and run-length coding to improve compression ratio. However, adaptive context modeling causes data dependency among adjacent pixels and the run-length coding has to be performed in a sequential way. Hence, using JPEG-LS to compress large-volume hyperspectral image data is quite time-consuming. We implement an efficient parallel JPEG-LS encoder for lossless hyperspectral compression on a NVIDIA GPU using the computer unified device architecture (CUDA) programming technology. We use the block parallel strategy, as well as such CUDA techniques as coalesced global memory access, parallel prefix sum, and asynchronous data transfer. We also show the relation between GPU speedup and AVIRIS block size, as well as the relation between compression ratio and AVIRIS block size. When AVIRIS images are divided into blocks, each with 64×64 pixels, we gain the best GPU performance with 26.3x speedup over its original CPU code.

  16. An exploratory examination of medical gas booms versus traditional headwalls in intensive care unit design.

    Science.gov (United States)

    Pati, Debajyoti; Evans, Jennie; Waggener, Laurie; Harvey, Tom

    2008-01-01

    Should power, medical gases, and monitoring and communications systems be located in a headwall or a ceiling-mounted boom in intensive care unit (ICU) rooms? Often, only the financial costs could be determined for the options, whereas data regarding its potential influence on teamwork, safety, and efficiency are lacking. Hence, purchase decisions are more arbitrary than evidence based. This study simulated care delivery in settings with a traditional headwall and a ceiling boom. Observed were the way the following elements were managed and the extent either system affected flexibility, ergonomics, and teamwork: tubing for intravenous fluids, medical gases, and suction drainage; monitoring leads and equipment power cords; and the medical equipment itself. Simulation runs involving 6 scenarios were conducted with the voluntary participation of 2 physicians, 2 nurse practitioners, 2 respiratory therapists, and 4 registered nurses at a children's tertiary care center in December 2007. Analysis suggests that booms have an advantage over headwalls in case of high-acuity ICU patients and when procedures are performed inside patient rooms. However, in case of lower-acuity ICU patients, as well as when procedures are not typically conducted in the patient room, booms may not provide a proportionate level of advantage when compared with the additional cost involved in its procurement.

  17. Design of a linear detector array unit for high energy x-ray helical computed tomography and linear scanner

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Tae; Park, Jong Hwan; Kim, Gi Yoon [Dept. of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon (Korea, Republic of); Kim, Dong Geun [Medical Imaging Department, ASTEL Inc., Seongnam (Korea, Republic of); Park, Shin Woong; Yi, Yun [Dept. of Electronics and Information Eng, Korea University, Seoul (Korea, Republic of); Kim, Hyun Duk [Research Center, Luvantix ADM Co., Ltd., Daejeon (Korea, Republic of)

    2016-11-15

    A linear detector array unit (LdAu) was proposed and designed for the high energy X-ray 2-d and 3-d imaging systems for industrial non-destructive test. Specially for 3-d imaging, a helical CT with a 15 MeV linear accelerator and a curved detector is proposed. the arc-shape detector can be formed by many LdAus all of which are arranged to face the focal spot when the source-to-detector distance is fixed depending on the application. An LdAu is composed of 10 modules and each module has 48 channels of CdWO{sub 4} (CWO) blocks and Si PIn photodiodes with 0.4 mm pitch. this modular design was made for easy manufacturing and maintenance. through the Monte carlo simulation, the CWO detector thickness of 17 mm was optimally determined. the silicon PIn photodiodes were designed as 48 channel arrays and fabricated with NTD (neutron transmutation doping) wafers of high resistivity and showed excellent leakage current properties below 1 nA at 10 V reverse bias. to minimize the low-voltage breakdown, the edges of the active layer and the guard ring were designed as a curved shape. the data acquisition system was also designed and fabricated as three independent functional boards; a sensor board, a capture board and a communication board to a Pc. this paper describes the design of the detectors (CWO blocks and Si PIn photodiodes) and the 3-board data acquisition system with their simulation results.

  18. Design for learning - a case study of blended learning in a science unit.

    Science.gov (United States)

    Gleadow, Roslyn; Macfarlan, Barbara; Honeydew, Melissa

    2015-01-01

    Making material available through learning management systems is standard practice in most universities, but this is generally seen as an adjunct to the 'real' teaching, that takes place in face-to-face classes. Lecture attendance is poor, and it is becoming increasingly difficult to engage students, both in the material being taught and campus life. This paper describes the redevelopment of a large course in scientific practice and communication that is compulsory for all science students studying at our Melbourne and Malaysian campuses, or by distance education. Working with an educational designer, a blended learning methodology was developed, converting the environment provided by the learning management system into a teaching space, rather than a filing system. To ensure focus, topics are clustered into themes with a 'question of the week', a pre-class stimulus and follow up activities. The content of the course did not change, but by restructuring the delivery using educationally relevant design techniques, the content was contextualised resulting in an integrated learning experience. Students are more engaged intellectually, and lecture attendance has improved. The approach we describe here is a simple and effective approach to bringing this university's teaching and learning into the 21 (st) century.

  19. Design for learning – a case study of blended learning in a science unit

    Science.gov (United States)

    Gleadow, Roslyn; Macfarlan, Barbara; Honeydew, Melissa

    2015-01-01

    Making material available through learning management systems is standard practice in most universities, but this is generally seen as an adjunct to the ‘real’ teaching, that takes place in face-to-face classes. Lecture attendance is poor, and it is becoming increasingly difficult to engage students, both in the material being taught and campus life. This paper describes the redevelopment of a large course in scientific practice and communication that is compulsory for all science students studying at our Melbourne and Malaysian campuses, or by distance education. Working with an educational designer, a blended learning methodology was developed, converting the environment provided by the learning management system into a teaching space, rather than a filing system. To ensure focus, topics are clustered into themes with a ‘question of the week’, a pre-class stimulus and follow up activities. The content of the course did not change, but by restructuring the delivery using educationally relevant design techniques, the content was contextualised resulting in an integrated learning experience. Students are more engaged intellectually, and lecture attendance has improved. The approach we describe here is a simple and effective approach to bringing this university’s teaching and learning into the 21 st century. PMID:26594348

  20. Operable Unit 3-13, Group 3, Other Surface Soils Remediation Sets 4-6 (Phase II) Remedial Design/Remedial Action Work Plan

    Energy Technology Data Exchange (ETDEWEB)

    D. E. Shanklin

    2006-06-01

    This Remedial Design/Remedial Action Work Plan provides the framework for defining the remedial design requirements, preparing the design documentation, and defining the remedial actions for Waste Area Group 3, Operable Unit 3-13, Group 3, Other Surface Soils, Remediation Sets 4-6 (Phase II) located at the Idaho Nuclear Technology and Engineering Center at the Idaho National Laboratory. This plan details the design developed to support the remediation and disposal activities selected in the Final Operable Unit 3-13, Record of Decision.

  1. A novel atmospheric Temperature Sounding Unit: system design and performance analyses

    Science.gov (United States)

    Chakraborty, Prantik; Gupta, Priyanka; Dave, Dilip B.; Desai, Nilesh M.; Misra, Tapan

    2016-05-01

    This paper reports the development of a millimeter-wave space-borne atmospheric Temperature Sounding Unit (TSU) in Indian Space Research Organization (ISRO). This is ISRO's first leap towards millimeter-wave technology. The sensor has several new accomplishments to its credit which include among others, the philosophy of sounding channel selection, the new assortment of temperature sounding channels, simultaneous observation of both polarizations of all channels, compact dual-band scanning Gregorian reflector antenna, indigenously developed black-body target for in-orbit calibration, in-house developed millimeter-wave RF front-end and pre-detection automatic gain control method. The prime feature of this instrument is its unique set of channels which can profile the earth's atmosphere from surface to 40 km altitude with vertical resolution ranging from less than a km near surface to +/-2.5 km at 30km altitude. The channels are predominantly off-resonant frequencies in the 50―60 GHz O2 absorption spectrum which offer near-uniform attenuation and hence more channel-bandwidth and better temperature sensitivity and yet have adequate overlap of their weighting functions to achieve the desired vertical resolution. These channels are different and have fewer bands from what has been flown in all earlier sounding missions worldwide e.g. AMSU-A, SSMIS, ATMS etc. The TSU radiometer has been characterized thoroughly using ingenious methods such as low-power active RF energizing along with frequency sweep. This is a compact, low-mass, low-power instrument and has been configured for the ISRO mini-satellite (IMS-2) bus. The flight model with improved hardware performance is being built and a suitable opportunity of flying it is being explored.

  2. Nosocomial infections in a pediatric intensive care unit of a developing country: NHSN surveillance

    Directory of Open Access Journals (Sweden)

    Juliana Pena Porto

    2012-08-01

    Full Text Available INTRODUCTION: This study aimed to determine the epidemiology of the three most common nosocomial infections (NI, namely, sepsis, pneumonia, and urinary tract infection (UTI, in a pediatric intensive care unit (PICU in a developing country and to define the risk factors associated with NI. METHODS: We performed a prospective study on the incidence of NI in a single PICU, between August 2009 and August 2010. Active surveillance by National Healthcare Safety Network (NHSN was conducted in the unit and children with NI (cases were compared with a group (matched controls in a case-control fashion. RESULTS: We analyzed 172 patients; 22.1% had NI, 71.1% of whom acquired it in the unit. The incidence densities of sepsis, pneumonia, and UTI per 1,000 patients/day were 17.9, 11.4, and 4.3, respectively. The most common agents in sepsis were Enterococcus faecalis and Escherichia coli (18% each; Staphylococcus epidermidis was isolated in 13% of cases. In pneumonias Staphylococcus aureus was the most common cause (3.2%, and in UTI the most frequent agents were yeasts (33.3%. The presence of NI was associated with a long period of hospitalization, use of invasive devices (central venous catheter, nasogastric tube, and use of antibiotics. The last two were independent factors for NI. CONCLUSIONS: The incidence of NI acquired in this unit was high and was associated with extrinsic factors.

  3. Influenza in hospitalized children in Ireland in the pandemic period and the 2010/2011 season: risk factors for paediatric intensive-care-unit admission.

    LENUS (Irish Health Repository)

    Rebolledo, J

    2013-11-11

    SUMMARY Influenza causes significant morbidity and mortality in children. This study\\'s objectives were to describe influenza A(H1N1)pdm09 during the pandemic, to compare it with circulating influenza in 2010\\/2011, and to identify risk factors for severe influenza defined as requiring admission to a paediatric intensive care unit (PICU). Children hospitalized with influenza during the pandemic were older, and more likely to have received antiviral therapy than children hospitalized during the 2010\\/2011 season. In 2010\\/2011, only one child admitted to a PICU with underlying medical conditions had been vaccinated. The risk of severe illness in the pandemic was higher in females and those with underlying conditions. In 2010\\/2011, infection with influenza A(H1N1)pdm09 compared to other influenza viruses was a significant risk factor for severe disease. An incremental relationship was found between the number of underlying conditions and PICU admission. These findings highlight the importance of improving low vaccination uptake and increasing the use of antivirals in vulnerable children.

  4. Development, dissemination and implementation of a sedation and analgesic guideline in a pediatric intensive care unit...it takes creativity and collaboration.

    Science.gov (United States)

    Thomas, Margot; Dhanani, Sonny; Irwin, Danica; Writer, Hilary; Doherty, Dermot

    2010-01-01

    Sedation and analgesia are administered to critically ill children to provide comfort and pain relief, decrease anxiety and to promote patient safety in relation to life-saving treatments. A comprehensive practice guideline focused on ways to implement evidence-based sedation and analgesia practices was developed, disseminated and implemented by an interprofessional team in the pediatric intensive care unit (PICU) at the Children's Hospital of Eastern Ontario (CHEO) in Ottawa, Canada. The goals of this quality of care initiative were to (1) reduce inconsistent practices, (2) improve patient outcomes related to comfort, and (3) enhance collaboration among health care team members caring for critically ill children. An evidence-based sedation and analgesia management (SAM) guideline for critically ill, intubated and ventilated infants and children was developed over a six-month period by a team composed of PICU physicians, pharmacists and nurses. The quality of patient care initiative focused on consistent use of (a) validated sedation and analgesia assessment tools, (b) a goal-directed approach by identifying daily therapeutic target scores and titrating interventions accordingly, and (c) non-pharmacologic, pharmacologic and adjunctive measures. The authors describe their experience in the development, dissemination and implementation of an interprofessional guideline directed at improving sedation and analgesia and patient safety in the PICU. Tools developed to support the practice change, challenges and lessons learned are shared.

  5. Low near infrared spectroscopic somatic oxygen saturation at admission is associated with need for lifesaving interventions among unplanned admissions to the pediatric intensive care unit.

    Science.gov (United States)

    Balakrishnan, Binod; Dasgupta, Mahua; Gajewski, Kim; Hoffmann, Raymond G; Simpson, Pippa M; Havens, Peter L; Hanson, Sheila J

    2017-03-03

    To investigate the association between low near infrared spectroscopy (NIRS) somatic oxygen saturation (admission and the need for lifesaving interventions (LSI) in the initial 24 h of a PICU admission. Retrospective chart review of all unplanned admissions to the pediatric intensive care unit (PICU) with NIRS somatic oxygen saturation data available within 4 h of admission, excluding admissions with a cardiac diagnosis. LSI data were collected for the first 24 h after admission. Hemodynamic parameters, laboratory values, illness severity scores and diagnoses were collected. Included PICU admissions were stratified by lowest NIRS value in the first 4 h after admission: low NIRS (admissions to the PICU of which 184 (44%) patients underwent NIRS monitoring. A higher proportion of patients who underwent somatic NIRS monitoring required LSIs compared to those without NIRS monitoring (36.4 vs 5.7% respectively, p medications were the most common LSIs. Multivariable modeling showed NIRS  2SD for age to be associated with LSIs. ROC curve analysis of the combination of NIRS 2SD for age had an area under the curve of 0.79 with 78% sensitivity and 76% specificity for association with LSI. Compared to the normal NIRS group, the low NIRS group had higher mortality (10.4 vs 0.7%, p = 0.005) and longer median hospital length of stay (2.9 vs 1.6 days, p admission is associated with need for higher number of subsequent lifesaving interventions up to 24 h after admission. Noninvasive, continuous, somatic NIRS monitoring may identify children at high risk of medical instability.

  6. Design of the wavefront sensor unit of ARGOS, the LBT laser guide star system

    CERN Document Server

    Bonaglia, Marco

    2012-01-01

    ARGOS is the laser guide star ground layer adaptive optics system of the LBT. ARGOS is designed to bring a moderate but uniform reduction of the PSF size over a FoV as large as 4x4arcmin, allowing a significative increase of the science throughput of LUCI, the LBT NIR imager and MOS. ARGOS relays on 3 Rayleigh beacons to sense the lower layers of the atmosphere achieving almost 100% sky coverage. The ground layer AO correction is allowed by the 2 adaptive secondaries of the LBT. This PhD thesis first discusses a study based on numerical simulations and aimed to evaluate the performance of ARGOS. This work has been carried out using CAOS and representing in the code most of the features that characterize the system itself: as the laser beacon propagation in the atmosphere, the SH type wavefront sensing, the AO reconstruction and closed loop delays and the atmosphere tip-tilt sensing done using a NGS and a quad-cell type sensor. The results obtained in this study are in agreement and definitively confirm the pe...

  7. Design optimization of large-size format edge-lit light guide units

    Science.gov (United States)

    Hastanin, J.; Lenaerts, C.; Fleury-Frenette, K.

    2016-04-01

    In this paper, we present an original method of dot pattern generation dedicated to large-size format light guide plate (LGP) design optimization, such as photo-bioreactors, the number of dots greatly exceeds the maximum allowable number of optical objects supported by most common ray-tracing software. In the proposed method, in order to simplify the computational problem, the original optical system is replaced by an equivalent one. Accordingly, an original dot pattern is splitted into multiple small sections, inside which the dot size variation is less than the ink dots printing typical resolution. Then, these sections are replaced by equivalent cells with continuous diffusing film. After that, we adjust the TIS (Total Integrated Scatter) two-dimensional distribution over the grid of equivalent cells, using an iterative optimization procedure. Finally, the obtained optimal TIS distribution is converted into the dot size distribution by applying an appropriate conversion rule. An original semi-empirical equation dedicated to rectangular large-size LGPs is proposed for the initial guess of TIS distribution. It allows significantly reduce the total time needed to dot pattern optimization.

  8. Design, fabrication, integration and commissioning of an upgraded guiding probe for the VLT unit telescope 4

    Science.gov (United States)

    Frank, Christoph; Hammersley, Peter; Buzzoni, Bernard; Manescau, Antonio; Arsenault, Robin; Madec, Pierre-Yves; Birkmann, Martin; Mueller, Michael; Salgado, Fernando; Guisard, Stephane; Kroedel, Matthias

    2014-07-01

    As part of the preparation for the arrival of the MUSE instrument to the VLT, it was required to adapt the hosting telescope (UT4) guide probe, to increase its back focal length. This is to allow enough space for the later deployment of the MUSE Adaptive Optics module GALACSI, in-between the telescope adapter rotator and the instrument itself. The UT guide probe is a critical component for the successful operation of the telescope, so its modification to increase the telescope's back focal length, while maintaining full compatibility with the existing operation model and other hardware, was rather demanding. The design, manufacture, assembly and test for the new supporting arm in the UT guiding probe is presented. It mixes the use of novel materials (HB-CESIC® for the mirrors substrates) and state of the art manufacturing techniques (3D printing mould production and rapid casting for the support structure), which allow producing easily a high performance subsystem. Characterization of the system prior delivery to the telescope, its integration in the UT and results after commissioning is presented. Its successful implementation has validated new manufacturing techniques that may prove very useful for future instruments development.

  9. Design and implementation of GRIP: a computerized glucose control system at a surgical intensive care unit

    Directory of Open Access Journals (Sweden)

    Zijlstra Felix

    2005-12-01

    Full Text Available Abstract Background Tight glucose control by intensive insulin therapy has become a key part of critical care and is an important field of study in acute coronary care. A balance has to be found between frequency of measurements and the risk of hypoglycemia. Current nurse-driven protocols are paper-based and, therefore, rely on simple rules. For safety and efficiency a computer decision support system that employs complex logic may be superior to paper protocols. Methods We designed and implemented GRIP, a stand-alone Java computer program. Our implementation of GRIP will be released as free software. Blood glucose values measured by a point-of-care analyzer were automatically retrieved from the central laboratory database. Additional clinical information was asked from the nurse and the program subsequently advised a new insulin pump rate and glucose sampling interval. Results Implementation of the computer program was uneventful and successful. GRIP treated 179 patients for a total of 957 patient-days. Severe hypoglycemia ( Conclusion A computer driven protocol is a safe and effective means of glucose control at a surgical ICU. Future improvements in the recommendation algorithm may further improve safety and efficiency.

  10. The optimal parameter design for a welding unit of manufacturing industry by Taguchi method and computer simulation

    Energy Technology Data Exchange (ETDEWEB)

    Zahraee, S.M.; Chegeni, A.; Toghtamish, A.

    2016-07-01

    Manufacturing systems include a complicated combination of resources, such as materials, labors, and machines. Hence, when the manufacturing systems are faced with a problem related to the availability of resources it is difficult to identify the root of the problem accurately and effectively. Managers and engineers in companies are trying to achieve a robust production line based on the maximum productivity. The main goal of this paper is to design a robust production line, taking productivity into account in the selected manufacturing industry. This paper presents the application of Taguchi method along with computer simulation for finding an optimum factor setting for three controllable factors, which are a number of welding machines, hydraulic machines, and cutting machines by analyzing the effect of noise factors in a selected manufacturing industry. Based on the final results, the optimal design parameter of welding unit of in the selected manufacturing industry will be obtained when factor A is located at level 2 and B and C are located at level 1. Therefore, maximum productive desirability is achieved when the number of welding machines, hydraulic machines, and cutting machines is equal to 17, 2, and 1, respectively. This paper has a significant role in designing a robust production line by considering the lowest cost and timely manner based on the Taguchi method. (Author)

  11. Optimization of Cycle and Expander Design of an Organic Rankine Cycle Unit using Multi-Component Working Fluids

    DEFF Research Database (Denmark)

    Meroni, Andrea; Andreasen, Jesper Graa; Pierobon, Leonardo

    2016-01-01

    the irreversibility in the ORC system. This work considers mixtures of R245fa/pentane and propane/isobutane. The use of multi-component working fluids typically results in increased heat transfer areas and different expander designs compared to purefluids. In order to properly account for turbine performance...... for an organic Rankine cycle unit utilizing waste heat from low temperature heat sources. The study addresses a case where the minimum temperature of the heat source is constrained and a case where no constraint is imposed. The former case is the wasteheat recovery from jacket cooling water of a marine diesel...... engine onboard a large ship, and the latter is representative of a low-temperature geothermal, solar or waste heat recovery application. Multi-component working fluids are investigated, as they allow improving the match between the temperature pro-files in the heat exchangers and, consequently, reducing...

  12. Applying Connectivist Principles and the Task-Based Approach to the Design of a Multimodal Didactic Unit

    Directory of Open Access Journals (Sweden)

    Yeraldine Aldana Gutiérrez

    2012-12-01

    Full Text Available This article describes the pedagogical intervention developed in a public school as part of the research “Exploring Communications Practices through Facebook as a Mediatic Device”, framed within the computer mediated communications field. Twelve ninth graders’ communications practices were explored and addressed by means of multimodal technological resources and tasks based on the connectivist learning view. As a result, a didactic unit was designed in the form of the digital book Diverface. This one in turn displayed information through different media channels and semiotic elements to support its multimodal features. Teachers and students might thus need to reconstruct an alternative multimodal literacy so that they can produce and interpret texts of the same nature in online environments.

  13. Development of Site-Specific Soil Design Basis Earthquake (DBE) Parameters for the Integrated Waste Treatment Unit (IWTU)

    Energy Technology Data Exchange (ETDEWEB)

    Payne, Suzette

    2008-08-01

    Horizontal and vertical PC 3 (2,500 yr) Soil Design Basis Earthquake (DBE) 5% damped spectra, corresponding time histories, and strain-compatible soil properties were developed for the Integrated Waste Treatment Unit (IWTU). The IWTU is located at the Idaho Nuclear Technology and Engineering Center (INTEC) at the Idaho National Laboratory (INL). Mean and 84th percentile horizontal DBE spectra derived from site-specific site response analyses were evaluated for the IWTU. The horizontal and vertical PC 3 (2,500 yr) Soil DBE 5% damped spectra at the 84th percentile were selected for Soil Structure Interaction (SSI) analyses at IWTU. The site response analyses were performed consistent with applicable Department of Energy (DOE) Standards, recommended guidance of the Nuclear Regulatory Commission (NRC), American Society of Civil Engineers (ASCE) Standards, and recommendations of the Blue Ribbon Panel (BRP) and Defense Nuclear Facilities Safety Board (DNFSB).

  14. Planning intensive care unit design using computer simulation modeling: optimizing integration of clinical, operational, and architectural requirements.

    Science.gov (United States)

    OʼHara, Susan

    2014-01-01

    Nurses have increasingly been regarded as critical members of the planning team as architects recognize their knowledge and value. But the nurses' role as knowledge experts can be expanded to leading efforts to integrate the clinical, operational, and architectural expertise through simulation modeling. Simulation modeling allows for the optimal merge of multifactorial data to understand the current state of the intensive care unit and predict future states. Nurses can champion the simulation modeling process and reap the benefits of a cost-effective way to test new designs, processes, staffing models, and future programming trends prior to implementation. Simulation modeling is an evidence-based planning approach, a standard, for integrating the sciences with real client data, to offer solutions for improving patient care.

  15. Conceptual design and selection of a biodiesel fuel processor for a vehicle fuel cell auxiliary power unit

    Science.gov (United States)

    Specchia, S.; Tillemans, F. W. A.; van den Oosterkamp, P. F.; Saracco, G.

    Within the European project BIOFEAT (biodiesel fuel processor for a fuel cell auxiliary power unit for a vehicle), a complete modular 10 kW e biodiesel fuel processor capable of feeding a PEMFC will be developed, built and tested to generate electricity for a vehicle auxiliary power unit (APU). Tail pipe emissions reduction, increased use of renewable fuels, increase of hydrogen-fuel economy and efficient supply of present and future APU for road vehicles are the main project goals. Biodiesel is the chosen feedstock because it is a completely natural and thus renewable fuel. Three fuel processing options were taken into account at a conceptual design level and compared for hydrogen production: (i) autothermal reformer (ATR) with high and low temperature shift (HTS/LTS) reactors; (ii) autothermal reformer (ATR) with a single medium temperature shift (MTS) reactor; (iii) thermal cracker (TC) with high and low temperature shift (HTS/LTS) reactors. Based on a number of simulations (with the AspenPlus® software), the best operating conditions were determined (steam-to-carbon and O 2/C ratios, operating temperatures and pressures) for each process alternative. The selection of the preferential fuel processing option was consequently carried out, based on a number of criteria (efficiency, complexity, compactness, safety, controllability, emissions, etc.); the ATR with both HTS and LTS reactors shows the most promising results, with a net electrical efficiency of 29% (LHV).

  16. Design of a computer software for calculation of required barrier against radiation at the diagnostic x-ray units

    Directory of Open Access Journals (Sweden)

    S.A. Rahimi

    2005-01-01

    Full Text Available Background and purpose : Instalation of protective barrier against diagnostic x-ray is generally done based on the recommendations of NCRP49. There are analytic methods for designing protective barriers howerer, they lack sufficient efficiency and considering the NCRP49 reports, designing mechanical protective barrier in order to protect the initial x-ray radiation and absorption of the ray quality of such radiation is different.Therefore, the protective barrier for each radiation is measured separately. In this study, a computer software was designed to calculate the needed barrier with high accuracy.Materials and methods: Calculation of required protective barrier particularly when two or more generators are in use at diagnostic x-ray units and or installed diagnostic equipments do not have proper room space and the limitations for other clanges in parameters which are time- consuming and impossible to be manually calculated. For proper determination of thichness of the protective barrier, relevant information about curves of radiation weakness, dose limit etc should be entered. This program was done in windows and designed in such a way that the operator works easily, flexibility of the program is acceptable and its accuracy and sensitivity is high.Results : Results of this program indicate that, in most cases, in x-ray units required protective barrier was not used. Meanwhile sometimes shielding is more than what required which lacks technical standards and cost effectiveness. When the application index is contrasting zero, thichness of NCRP49 calculation is about 20% less than the calculated rate done by the method of this study. When the applied index is equal to zero (that is the only situation where the second barrier is considered, thickness of requined barrier is about 15% less than the lead barrier and concrete barrier calculated in this project is 8% less than that calculated by McGuire method.Conclusion : In this study proper

  17. Influence of retainer design on two-unit cantilever resin-bonded glass fiber reinforced composite fixed dental prostheses: An in vitro and finite element analysis study

    NARCIS (Netherlands)

    Keulemans, F.; de Jager, N.; Kleverlaan, C.J.; Feilzer, A.J.

    2008-01-01

    Purpose: The aim of this study was to evaluate in vitro the influence of retainer design on the strenght of two-unit cantilever resin-bonded glass fiber-reinforced composite (FRC) fixed dental prostheses (FDP). Conclusion: A dual-wing retainer is the optimal design for replacement of a single premol

  18. Influence of retainer design on two-unit cantilever resin-bonded glass fiber reinforced composite fixed dental prostheses: An in vitro and finite element analysis study

    NARCIS (Netherlands)

    Keulemans, F.; de Jager, N.; Kleverlaan, C.J.; Feilzer, A.J.

    2008-01-01

    Purpose: The aim of this study was to evaluate in vitro the influence of retainer design on the strenght of two-unit cantilever resin-bonded glass fiber-reinforced composite (FRC) fixed dental prostheses (FDP). Conclusion: A dual-wing retainer is the optimal design for replacement of a single

  19. Effectiveness of classroom based crew resource management training in the intensive care unit: study design of a controlled trial

    Directory of Open Access Journals (Sweden)

    Kemper Peter F

    2011-11-01

    Full Text Available Abstract Background Crew resource management (CRM has the potential to enhance patient safety in intensive care units (ICU by improving the use of non-technical skills. However, CRM evaluation studies in health care are inconclusive with regard to the effect of this training on behaviour and organizational outcomes, due to weak study designs and the scarce use of direct observations. Therefore, the aim of this study is to determine the effectiveness and cost-effectiveness of CRM training on attitude, behaviour and organization after one year, using a multi-method approach and matched control units. The purpose of the present article is to describe the study protocol and the underlying choices of this evaluation study of CRM in the ICU in detail. Methods/Design Six ICUs participated in a paired controlled trial, with one pre-test and two post test measurements (respectively three months and one year after the training. Three ICUs were trained and compared to matched control ICUs. The 2-day classroom-based training was delivered to multidisciplinary groups. Typical CRM topics on the individual, team and organizational level were discussed, such as situational awareness, leadership and communication. All levels of Kirkpatrick's evaluation framework (reaction, learning, behaviour and organisation were assessed using questionnaires, direct observations, interviews and routine ICU administration data. Discussion It is expected that the CRM training acts as a generic intervention that stimulates specific interventions. Besides effectiveness and cost-effectiveness, the assessment of the barriers and facilitators will provide insight in the implementation process of CRM. Trial registration Netherlands Trial Register (NTR: NTR1976

  20. The EU-project United4Health: User-centred design of an information system for a Norwegian telemedicine service.

    Science.gov (United States)

    Smaradottir, Berglind; Gerdes, Martin; Martinez, Santiago; Fensli, Rune

    2016-10-01

    Organizational changes of health care services in Norway brought to light a need for new clinical pathways. This study presents the design and evaluation of an information system for a new telemedicine service for chronic obstructive pulmonary disease patients after hospital discharge. A user-centred design approach was employed composed of a workshop with end-users, two user tests and a field trial. For data collection, qualitative methods such as observations, semi-structured interviews and a questionnaire were used. User workshop's outcome informed the implementation of the system initial prototype, evaluated by end-users in a usability laboratory. Several usability and functionality issues were identified and solved, such as the interface between the initial colour scheme and the triage colours. Iterative refinements were made and a second user evaluation showed that the main issues were solved. The responses to a questionnaire presented a high score of user satisfaction. In the final phase, a field trial showed satisfactory use of the system. This study showed how the target end-users groups were actively involved in identifying the needs, suggestions and preferences. These aspects were addressed in the development of an information system through a user-centred design process. The process efficiently enabled users to give feedback about design and functionality. Continuous refinement of the system was the key to full development and suitability for the telemedicine service. This research was a result of the international cooperation between partners within the project United4Health, a part of the Seventh Framework Programme for Research of the European Union. © The Author(s) 2015.

  1. Design, fabrication, assembly, and testing of the Florida image slicer for infrared cosmology and astrophysics (FISICA) integral field unit

    Science.gov (United States)

    Glenn, Paul E.; Hull-Allen, C. Gregory; Hoffman, Jeff; Rodgers, Michael; Thompson, Kevin; Myrick, Bruce; Comstock, Lovell; Flint, Scott; Boreman, Glenn; Eikenberry, Stephen S.; Elston, Richard; Guzman, Rafael; Julian, Jeff; Raines, S. Nicholas

    2004-09-01

    We discuss the design, fabrication, assembly, and testing of the prototype Florida Image Slicer for Infrared Cosmology and Astrophysics (FISICA) Integral Field Unit (IFU). FISICA is intended for large telescopes with f/numbers close to f/15, such as the KPNO 4-m and GTC 10.4-m telescopes. It implements an image slicing approach, wherein the initial image plane is optically sliced into thin strips and the strips are optically rearranged end-to-end, whereupon the composite slit image is fed into a conventional spectrograph. We divide the field of view into 22 slices, while accommodating the entire f/15 viewing solid angle. The all-reflective instrument resides in a cryogenic dewar at the initial focal plane, and places the composite slit image output precisely at the initial focus, allowing it to interface to the existing FLAMINGOS spectrograph. The mirrors were diamond turned using various tool geometries and state-of-the-art, multi-axis tool control. The mirrors are made from a single billet of aluminum, and the optical bench and mounts are made of the same alloy as the mirrors for optimum performance during cryogenic cooling. We discuss the key design efforts, emphasizing tradeoffs among performance, volume, fabrication difficulty, and alignment requirements. We describe the fabrication, and present preliminary laboratory test results.

  2. Design and development of low pressure evaporator/condenser unit for water-based adsorption type climate control systems

    Science.gov (United States)

    Venkataramanan, Arjun; Rios Perez, Carlos A.; Hidrovo, Carlos H.

    2016-11-01

    Electric vehicles (EVs) are the future of clean transportation and driving range is one of the important parameters which dictates its marketability. In order to increase driving range, electrical battery energy consumption should be minimized. Vapor-compression refrigeration systems currently employed in EVs for climate control consume a significant fraction of the battery charge. Thus, by replacing this traditional heating ventilation and air-conditioning system with an adsorption based climate control system one can have the capability of increasing the drive range of EVs.The Advanced Thermo-adsorptive Battery (ATB) for climate control is a water-based adsorption type refrigeration cycle. An essential component of the ATB is a low pressure evaporator/condenser unit (ECU) which facilitates both the evaporation and condensation processes. The thermal design of the ECU relies predominantly on the accurate prediction of evaporation/boiling heat transfer coefficients since the standard correlations for predicting boiling heat transfer coefficients have large uncertainty at the low operating pressures of the ATB. This work describes the design and development of a low pressure ECU as well as the thermal performance of the actual ECU prototype.

  3. SparsePak: A Formatted Fiber Field Unit for The WIYN Telescope Bench Spectrograph. I. Design, Construction, and Calibration

    CERN Document Server

    Bershady, M A; Harker, J; Ramsey, L W; Verheijen, M A W

    2004-01-01

    We describe the design and construction of a formatted fiber field-unit, SparsePak, and characterize its optical and astrometric performance. This array is optimized for spectroscopy of low-surface brightness, extended sources in the visible and near-infrared. SparsePak contains 82, 4.7" fibers subtending an area of 72"x71" in the telescope focal plane, and feeds the WIYN Bench spectrograph. Together, these instruments are capable of achieving spectral resolutions of lambda/dlambda ~ 20000 and an area--solid-angle product of ~140 arcsec^2 m^2 per fiber. Laboratory measurements of SparsePak lead to several important conclusions on the design of fiber termination and cable curvature to minimize focal ratio degradation. SparsePak itself has throughput >80% redwards of 5200 A, and 90-92% in the red. Fed at f/6.3, the cable delivers an output 90% encircled energy at nearly f/5.2. This has implications for performance gains if the WIYN Bench Spectrograph had a faster collimator. Our approach to integral-field spect...

  4. LIFAC demonstration at Richmond Power and Light Whitewater Valley Unit No. 2. Final report, Volume 1 - public design

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    This report discusses the demonstration of LIFAC sorbent injection technology at Richmond Power and Light`s (RP&L) Whitewater Valley Unit No. 2 under the auspices of the U.S. Department of Energy`s (DOE) Clean Coal Technology Program. LIFAC is a sorbent injection technology capable of removing 75 to 85 percent of a power plant`s SO{sub 2} emissions using limestone at calcium to sulfur molar ratios of between 2 and 2.5. The site of the demonstration is a coal-fired electric utility power plant located in Richmond, Indiana. The project is being conducted by LIFAC North American (LIFAC NA), a joint venture partnership of Tampella Power Corporation and ICF Kaiser Engineers, in cooperation with DOE, RP&L, and several other organizations including the Electric Power Research Institute (EPRI), the State of Indiana, and Black Beauty Coal Company. The purpose of Final Report Volume 1: Public Design is to consolidate, for public use, all design and cost information regarding the LIFAC Desulfurization Facility at the completion of construction and startup.

  5. Impact of flow induced vibration acoustic loads on the design of the Laguna Verde Unit 2 steam dryer

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, D. R.; Wellstein, L. F.; Theuret, R. C.; Han, Y.; Rajakumar, C. [Westinghouse Electric Company LLC, Cranberry Township, PA 16066 (United States); Amador C, C.; Sosa F, W., E-mail: forsytdr@westinghouse.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Km 42.5 Carretera Cardel-Nautla, 91680 Alto Lucero, Veracruz (Mexico)

    2015-09-15

    Industry experience with Boiling Water Reactors (BWRs) has shown that increasing the steam flow through the main steam lines (MSLs) to implement an extended power up rate (EPU) may lead to amplified acoustic loads on the steam dryer, which may negatively affect the structural integrity of the component. The source of these acoustic loads has been found to be acoustic resonance of the side branches on the MSLs, specifically, coupling of the vortex shedding frequency and natural acoustic frequency of safety relief valves (SRVs). The resonance that results from this coupling can contribute significant acoustic energy into the MSL system, which may propagate upstream into the reactor pressure vessel steam dome and drive structural vibration of steam dryer components. This can lead to high-cycle fatigue issues. Lock-in between the vortex shedding frequency and SRV natural frequency, as well as the ability for acoustic energy to propagate into the MSL system, are a function of many things, including the plant operating conditions, geometry of the MSL/SRV junction, and placement of SRVs with respect to each other on the MSLs. Comision Federal de Electricidad and Westinghouse designed, fabricated, and installed acoustic side branches (ASBs) on the MSLs which effectively act in the system as an energy absorber, where the acoustic standing wave generated in the side-branch is absorbed and dissipated inside the ASB. These ASBs have been very successful in reducing the amount of acoustic energy which propagates into the steam dome. In addition, modifications to the Laguna Verde Nuclear Power Plant Unit 2 steam dryer have been completed to reduce the stress levels in critical locations in the dryer. The objective of this paper is to describe the acoustic side branch concept and the design iterative processes that were undertaken at Laguna Verde Unit 2 to achieve a steam dryer design that meets the guidelines of the American Society of Mechanical Engineers, Boiler and Pressure

  6. Designating Earth's Moon as a United Nations World Heritage Site - Permanently Protected from Commercial or Military Uses

    Science.gov (United States)

    Steiner, R. G.

    2002-01-01

    This paper proposes that Earth's Moon, in its entirety, be designated a United Nations World Heritage Site (WHS), permanently protected from any and all commercial or military utilization and reserved exclusively for scientific and aesthetic purposes. The paper discusses: 1) the extraordinary importance of the Moon for science, culture, and religion - past, present and future; 2) the history of proposals to exploit the Moon for commercial and military purposes and the shortcomings of this colonial, exploitation paradigm; and 3) the necessity, policy mechanisms, and political dynamics of designating the Moon as a World Heritage Site, permanently protected from commercial and/or military uses. The first part of the paper discusses the extraordinary importance of the Moon as it exists today - as a scientific laboratory, a source of beauty and inspiration throughout human evolution, a source for artistic expression, and as an object that is considered sacred by many cultures. Next, the paper traces the history of specific proposals for the exploitation of the Moon for commercial and/or military purposes - including plans by the U.S. Air Force in 1959 to detonate a nuclear explosion on the Moon, proposals to strip-mine the lunar regolith for helium-3 and rocket-fuel hydrogen; construction of solar power plants to transmit energy to Earth, and proposals to use the lunar surface as a billboard upon which to project commercial advertisements visible from Earth. The profound ethical, legal, and scientific shortcomings of this exploitation paradigm are described as an emerging Extraterrestrial Manifest Destiny that we have a collective obligation to challenge and constrain. The paper proposes that space exploration be infused with an ethical commitment to compassion, reverence, conservation, and non-interference to abiotic and biotic systems alike; as opposed to the expansion and extraterrestrial imposition of the colonization, exploitation, domination, and despoliation

  7. Project Experience of MMIS for Shin-Hanul units 1 and 2 (Component Design, Manufacturing and Testing)

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Seo-ryong; Kim, Kook-hun [Doosan Heavy Industries and Construction Co. Ltd., Hwaseong (Korea, Republic of)

    2015-10-15

    Doosan is uniquely positioned in the field of nuclear power plant in the world-wide. Doosan has secured the first step to nuclear technology field through the development of the nuclear power plant (NPP) man machine interface system (MMIS), which is one of the three major core technologies of non-independence. In the nuclear power plant, MMIS takes a function as the brain and nerve system in the human body. Korean MMIS was selected for the Shin-Hanul units 1 and 2 for the first time and Doosan is charge of a component design and equipment supply. At the end of successful completion of MMIS for Shin-Hanul units 1 and 2, Doosan will be a total provider of the MMIS from development, validation, and manufacturing to delivery in Korea. Man Machine Interface System (MMIS) is equivalent to the brain and nerve system of a nuclear power plant. It monitors and controls the operating conditions to prevent accidents proactively. Doosan achieved a complete development of MMIS which is core part of nuclear technology that was relied on oversea's companies in the past by an accomplishment of RnD in cooperation with domestic utility, KHNP and research institutions. Doosan's MMIS is very user-friendly, easy to understand, transparent to audits, and guarantees maximum reliability, availability, maintainability, and safety. Doosan proved safety and reliability through test and inspection of integrated function of nuclear safety and non-safety control system. Doosan MMIS was evaluated a one of the best system through IAEA IERIC's review via safety guide from IAEA specialist's group in 2010. Doosan also achieved the improvements of quality through the KINS audits in 2014.

  8. Effectiveness of classroom based crew resource management training in the intensive care unit: study design of a controlled trial.

    Science.gov (United States)

    Kemper, Peter F; de Bruijne, Martine; van Dyck, Cathy; Wagner, Cordula

    2011-11-10

    Crew resource management (CRM) has the potential to enhance patient safety in intensive care units (ICU) by improving the use of non-technical skills. However, CRM evaluation studies in health care are inconclusive with regard to the effect of this training on behaviour and organizational outcomes, due to weak study designs and the scarce use of direct observations. Therefore, the aim of this study is to determine the effectiveness and cost-effectiveness of CRM training on attitude, behaviour and organization after one year, using a multi-method approach and matched control units. The purpose of the present article is to describe the study protocol and the underlying choices of this evaluation study of CRM in the ICU in detail. Six ICUs participated in a paired controlled trial, with one pre-test and two post test measurements (respectively three months and one year after the training). Three ICUs were trained and compared to matched control ICUs. The 2-day classroom-based training was delivered to multidisciplinary groups. Typical CRM topics on the individual, team and organizational level were discussed, such as situational awareness, leadership and communication. All levels of Kirkpatrick's evaluation framework (reaction, learning, behaviour and organisation) were assessed using questionnaires, direct observations, interviews and routine ICU administration data. It is expected that the CRM training acts as a generic intervention that stimulates specific interventions. Besides effectiveness and cost-effectiveness, the assessment of the barriers and facilitators will provide insight in the implementation process of CRM. Netherlands Trial Register (NTR): NTR1976.

  9. 基于QFD和TRIZ的抽油机概念设计方法%The Conceptual Design Method for a Pumping Unit Based on QFD and TRIZ

    Institute of Scientific and Technical Information of China (English)

    张鹏; 盖峰; 管虹翔; 李萍

    2005-01-01

    Quality function deployment (QFD) is a quality system,that can help to design novel products that meet customers' needs. Theory of inventive problem solving (TRIZ) is a very powerful tool in helping to solve difficult technical problems encountered in the design process. Introducing QFD and TRIZ into the conceptual design of the pumping unit combines advantages of these two theories, therefore meeting different demands of different users. It can tell us "What should we do it" with QFD and "How should we do it" with TRIZ. The conceptual design method, which is based on QFD and TRIZ, is introduced and used to analyze and evaluate the conceptual design project of a pumping unit.

  10. Clinical research of ε-polylysine in the prevention of ventilator-associated pneumonia for children with mechanical ventilation in PICU%ε-聚赖氨酸预防儿科重症监护室机械通气患儿呼吸机相关性肺炎的效果研究

    Institute of Scientific and Technical Information of China (English)

    张馨心; 左泽兰

    2015-01-01

    Objective To investigate the effect of ε-polylysine to prevent ventilator-associated pneumonia ( VAP) for children with mechanical ventilation in Pediatric Intensive Care Unit ( PICU ) and to provide evidence-based procedure for clinical VAP prevention.Methods A total of ninety children with mechanical ventilation in PICU from January to September in 2012 were randomly divided into three groups averagely:experimental group A and B (3 timesε-polylysine intervention daily as group A,2 timesε-polylysine intervention daily as group B) and control group ( non-ε-polylysine-intervention as group C) .All cases had been numbered by time sequence.ε-polylysine was sprayed to Y-interface.The incidences of VAP were targeted monitored, and sampling bacteria on lower respiratory tract and various parts of ventilator tubing ( thread-inlet end and outlet end interface, condensate of inlet and outlet section, Y-type interface, wet tank) had been isolated, cultured and counted.Results The rates of VAP were 10%, 30%and 70%respectively in group A, B and C (χ2 =24.115;P<0.01), while the time of mechanical ventilation in three groups were (4.2 ±0.4), (5.2 ±0.7) and (7.1 ±0.3)h (F=260.953;P<0.01).In the fourth day and seventh day, we compared the numbers of bacteria in children′s respiration and tube for air admission, tube for air outlet and Y-type interface indicated statistical significance (χ2 =12.115-34.658,P<0.01).On the fourth day and fifth to eighth day, we compared children patients′bacteria amount in condensate water for ventilator′s air inlet and outlet in three groups, it showed that they had statistical significance (χ2 =12.604 -47.624;P <0.01). Conclusions The use of 28 μg/ml ε-polylysine 3 times daily can effectively control bacterial colonization in ventilator tubing, cut off infection from exogenous route, reduce the incidence of VAP, shorten mechanical ventilation time and improve the prognosis, and make more important guiding significance on clinical

  11. Pharmacist Remote Review of Medication Prescriptions for Appropriateness in Pediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Moran Lazaryan

    2016-08-01

    Full Text Available Background: One aspect of ordering and prescribing medication is the requirement for a trained professional to review medication orders or prescriptions for appropriateness. In practice, this review process is usually performed by a clinical pharmacist. However, in many medical centers there is a shortage of staff and a pharmacist is not always available.Objective: To determine whether remote review of medication orders by a pharmacist is a plausible method in a pediatric intensive care unit (PICU. Methods: A pharmacist from the pharmacy department reviewed medication orders of patients admitted to our PICU over a 7-month period for appropriateness. A special form for medical orders was filled in and sent to the physician in the PICU, who replied informing whether the recommendation had been accepted. The time spent by the pharmacist for this activity was recorded.Results: The review time for one medical record was 8.9 (95% CI, 6.9-10.9 minutes. Every additional drug prescribed increased the total review time by 0.8 (95% CI, 0.45-1.11 minutes. The pharmacist filled in 186 forms on 117 admissions for 109 children. The median review time was 15 (12.8-18.8 and 12 (9-15 minutes, respectively, for patients with psychiatric-neurologic disorders compared to those without (p=0.032. Usually, a daily workload of 240 minutes was needed for the pharmacist accompanying the round in contrast to 108 minutes per day needed to review all the medical records in 95% of the cases. The physician accepted 51.2%, rejected 11.9% and made no comment on 36.9% of the recommendations. Conclusion: Hospitals facing budget shortages can carry out focused remote reviews of prescriptions by the pharmacist.

  12. A study on room design and radiation safety around room for Co-60 after loading HDR brachytherapy unit converted from room for Ir-192 after loading HDR brachytherapy unit

    Directory of Open Access Journals (Sweden)

    Om Prakash Gurjar

    2015-01-01

    Full Text Available Context: Use of Co-60 source in place of Ir-192 in high dose rate brachytherapy unit (HDR unit has come for discussion in recent publications. Co-60 based system has been advocated for centers which have fewer brachytherapy procedures as it has comparative economically and administrative advantage. This study has direct practical application for such institutions, which are at the cusp of moving from Ir-192 to Co-60 based brachytherapy. Aims: Conversion of Ir-192 HDR room to Co-60 HDR room and to analyze radiation safety around the room. Materials and Methods: Uniform thickness of 15 cm concrete was added to all walls (except one wall adjoining to linear accelerator bunker to convert existing room forIr-192 HDR unit to suitable room for Co-60 HDR unit. Radiation survey around room was done. Actual and calculated wall thicknesses were compared. Results: Radiation survey data indicates that modified room is suitable for Co-60 HDR unit and all values are in full conformity to annual dose limits mentioned in Safety Code for Radiation Therapy Sources (SCRTS, Atomic Energy Regulatory Body (AERB; the regulatory body in India. Also, modified wall thicknesses are appropriate for annual design dose limits mentioned in Safety Report Series No. 47 of International Atomic Energy Agency (IAEA. However, console wall thickness (0.45 m is less than the calculated thickness (0.53 m for instantaneous dose rate (IDR design dose limit (7.5 ΅Sv/h as perabove safety report of IAEA. Conclusions: The modified wall thicknesses are appropriate for annual design dose limits. However, console wall thickness is less than the required thickness for IDR design dose limit. It has been suggested to add 2.64 cm steel on console wall. It has been found that design dose limits should be considered while making room layout plan and regulatory body should add these constraints inSCRTS.

  13. 渣油加氢装置节能优化设计%Optimization design for residue hydrodesulfurization unit

    Institute of Scientific and Technical Information of China (English)

    马书涛

    2012-01-01

    介绍了某公司新建2.5 Mt/a渣油加氢处理装置工艺概况及原设计节能措施,从操作参数、工艺流程设置及能量综合利用等方面,介绍了汽、电、燃料和水等方面的节能优化方案,并提出以下改进措施:①降低空冷入口温度,回收低温热;②降低烟气温度,提高加热炉效率;③循环氢压缩机采用背压式汽轮机;④新氢压缩机采用常规逐 级返回流程,可选用HydroCom系统,提浓氢单独设置压缩机;⑤过滤器反冲洗油直接送催化裂化装置;⑥空冷器与加热炉风机采用变频技术;⑦优化流程,降低循环水用量;⑧优化换热流程,提高发生蒸汽品质与流量;⑨设置液力透平,回收能量;⑩调整机泵选型,选择高效机泵.节能优化设计使装置能耗比原设计低296.78 MJ/t,年经济效益约为1 000 ×104 RMB¥.%The process and the original energy-saving design of a 2.5 MM TPY residue hydrodesulfuration unit are introduced. Based on the operating parameters, the design of process flow and comprehensive energy saving optimization plans for steam saving, power saving, fuel gas saving and water saving are described respectively , and corresponding improvement measures are presented: ?air cooler inlet temperature is reduced and lower-temperature heat is recovered; ②flue gas temperature is lowered and the efficiency of furnace is improved ; ③the recycle gas compressor with backpressure turbine is adopted; ④ makeup gas compressor can use conventional sequential return flow and select HydroCom system, and bleed gas compressor is provided separately; ⑤ the sump oil of feed filter is directly sent to RFCC; ⑥the variable frequency technology is applied for the air cooler and the heater air blower; ⑦process is optimized to reduce cooling water requirement; ?the heat exchange process is optimized to improve the quality of steam and increase steam flowrate; ⑨ hydraulic turbine is installed to recovery energy

  14. Design, Analysis and Fabrication of Secondary Structural Components for the Habitat Demonstration Unit-Deep Space Habitat

    Science.gov (United States)

    Smith, Russell W.; Langford, William M.

    2012-01-01

    In support of NASA s Habitat Demonstration Unit - Deep Space Habitat Prototype, a number of evolved structural sections were designed, fabricated, analyzed and installed in the 5 meter diameter prototype. The hardware consisted of three principal structural sections, and included the development of novel fastener insert concepts. The articles developed consisted of: 1) 1/8th of the primary flooring section, 2) an inner radius floor beam support which interfaced with, and supported (1), 3) two upper hatch section prototypes, and 4) novel insert designs for mechanical fastener attachments. Advanced manufacturing approaches were utilized in the fabrication of the components. The structural components were developed using current commercial aircraft constructions as a baseline (for both the flooring components and their associated mechanical fastener inserts). The structural sections utilized honeycomb sandwich panels. The core section consisted of 1/8th inch cell size Nomex, at 9 lbs/cu ft, and which was 0.66 inches thick. The facesheets had 3 plys each, with a thickness of 0.010 inches per ply, made from woven E-glass with epoxy reinforcement. Analysis activities consisted of both analytical models, as well as initial closed form calculations. Testing was conducted to help verify analysis model inputs, as well as to facilitate correlation between testing and analysis. Test activities consisted of both 4 point bending tests as well as compressive core crush sequences. This paper presents an overview of this activity, and discusses issues encountered during the various phases of the applied research effort, and its relevance to future space based habitats.

  15. DSM-5 field trials in the United States and Canada, Part I: study design, sampling strategy, implementation, and analytic approaches.

    Science.gov (United States)

    Clarke, Diana E; Narrow, William E; Regier, Darrel A; Kuramoto, S Janet; Kupfer, David J; Kuhl, Emily A; Greiner, Lisa; Kraemer, Helena C

    2013-01-01

    This article discusses the design,sampling strategy, implementation,and data analytic processes of the DSM-5 Field Trials. The DSM-5 Field Trials were conducted by using a test-retest reliability design with a stratified sampling approach across six adult and four pediatric sites in the United States and one adult site in Canada. A stratified random sampling approach was used to enhance precision in the estimation of the reliability coefficients. A web-based research electronic data capture system was used for simultaneous data collection from patients and clinicians across sites and for centralized data management.Weighted descriptive analyses, intraclass kappa and intraclass correlation coefficients for stratified samples, and receiver operating curves were computed. The DSM-5 Field Trials capitalized on advances since DSM-III and DSM-IV in statistical measures of reliability (i.e., intraclass kappa for stratified samples) and other recently developed measures to determine confidence intervals around kappa estimates. Diagnostic interviews using DSM-5 criteria were conducted by 279 clinicians of varied disciplines who received training comparable to what would be available to any clinician after publication of DSM-5.Overall, 2,246 patients with various diagnoses and levels of comorbidity were enrolled,of which over 86% were seen for two diagnostic interviews. A range of reliability coefficients were observed for the categorical diagnoses and dimensional measures. Multisite field trials and training comparable to what would be available to any clinician after publication of DSM-5 provided “real-world” testing of DSM-5 proposed diagnoses.

  16. Design, Fabrication and pseudo Field Evaluation of a Sugar Beet Crust Breaker and Weeding Unit Equipped with an Infrared Sensor

    Directory of Open Access Journals (Sweden)

    E Chaligar

    2014-09-01

    Full Text Available In conventional cultivation of sugar beet the weeding and crust breaking are mostly performed manually. The objectives of this research were to design, fabricate and evaluate a soil crust breaker and weeding implement equipped with a detecting sensor. Each unit consisted of a distance detecting sensor and a hydro-motor for driving the blades and pneumatic valves for moving the blades. The hydro-motor was activated by the sensors. To avoid damaging the plants, a command signal was sent to the pneumatic valves to move the blades up and down and pass safely. Three configurations of cutting blades were considered which could be mounted to the crust breaker. The field evaluation was conducted with two tractor forward speeds (0.4 and 1 km h-1 and four plant-to-plant spacings within rows (20, 25, 30 and 40 cm all with three different blade shapes. For field evaluation split plot experiments arranged in a completely randomized block design with three replications. The number of plants damaged (evaluated only for four-lobe blades and size of broken crusts (evaluated for all blade shapes for various treatments were recorded and compared. The results of analysis indicated that the higher the inter-row spacing the lower the injury to the plant. The highest and the least damage to the plants occurred for within-row plant spacings of 20 and 40 cm, respectively. The forward speed was also significantly affected the percent of plant damaged. The forward speed of 1 km h-1 at 20 cm spacing had the most (59% and the speed of 0.40 km h-1 at 40 cm spacing had the least effect (3.3% on the percent of plant damage. The two-lobe blade could result in the maximum surface area broken.

  17. The Apartment Layout Design Characteristics of Commercial Residential Units%商品化住宅中的户型设计的特点

    Institute of Scientific and Technical Information of China (English)

    谢晓璐

    2013-01-01

    本文根据笔者在商品住宅方面的设计工作实践,针对商品化住宅的户型特点进行了探讨,并总结出了商品化住宅在户型设计方面的特殊性。%In this article, the author bases on the design prac-tice of commodity residential house to discuss the characterist-ics of the commercial residential units and sums up the particu-larity of commercial units in the apartment layout design.

  18. Analyzing the Deployment of Large Amounts of Offshore Wind to Design an Offshore Transmission Grid in the United States: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Ibanez, E.; Mai, T.; Coles, L.

    2012-09-01

    This paper revisits the results from the U.S. Department of Energy's '20% Wind Energy By 2030' study, which envisioned that 54 GW of offshore wind would be installed by said year. The analysis is conducted using the Regional Energy Deployment System (ReEDS), a capacity expansion model developed by the National Renewable Energy Laboratory. The model is used to optimize the deployment of the 54 GW of wind capacity along the coasts and lakes of the United States. The graphical representation of the results through maps will be used to provide a qualitative description for planning and designing an offshore grid. ReEDS takes into account many factors in the process of siting offshore wind capacity, such as the quality of the resource, capital and O&M costs, interconnection costs, or variability metrics (wind capacity value, forecast error, expected curtailment). The effect of these metrics in the deployment of offshore wind will be analyzed through examples in the results.

  19. Improved PI-PD control design using predictive functional optimization for temperature model of a fluidized catalytic cracking unit.

    Science.gov (United States)

    Zou, Hongbo; Li, Haisheng

    2017-03-01

    Proportional-integral-derivative (PID) control is widely used in industry because of its simple structure and convenient implementation. However, PID control is suitable for small time delay systems; while if too large delay is encountered, PID control may not obtain the desired performance. Proportional-integral-proportional-derivative (PI-PD) control is a modified of PID control and can get improved control performance; however, due to the complex controller parameter tuning, the PI-PD control is used in a limited scope. Inspired by the advantage of predictive functional control (PFC), a new PI-PD control design using PFC optimization is proposed in this paper. The proposed method not only inherits the advantage of PFC, which does well in coping with the time delay, but also has the same structure as the PI-PD controller. The proposed method is tested on the preheated temperature control of crude oil in a fluidized catalytic cracking unit. The results show that the proposed controller improves control performance compared with typical PID control and PI-PD control.

  20. Compact Design of 10 kW Proton Exchange Membrane Fuel Cell Stack Systems with Microcontroller Units

    Directory of Open Access Journals (Sweden)

    Hsiaokang Ma

    2014-04-01

    Full Text Available In this study, fuel, oxidant supply and cooling systems with microcontroller units (MCU are developed in a compact design to fit two 5 kW proton exchange membrane fuel cell (PEMFC stacks. At the initial stage, the testing facility of the system has a large volume (2.0 m × 2.0 m × 1.5 m with a longer pipeline and excessive control sensors for safe testing. After recognizing the performance and stability of stack, the system is redesigned to fit in a limited space (0.4 m × 0.5 m × 0.8 m. Furthermore, the stack performance is studied under different hydrogen recycling modes. Then, two similar 5 kW stacks are directly coupled with diodes to obtain a higher power output and safe operation. The result shows that the efficiency of the 5 kW stack is 43.46% with a purge period of 2 min with hydrogen recycling and that the hydrogen utilization rate µf is 66.31%. In addition, the maximum power output of the twin-coupled module (a power module with two stacks in electrical cascade/parallel arrangement is 9.52 kW.

  1. Design of a Distributed Control System Using a Personal Computer and Micro Control Units for Humanoid Robots

    Directory of Open Access Journals (Sweden)

    Mitsuhiro Yamano

    2010-01-01

    Full Text Available Problem statement: Humanoid robots have many motors and sensors and many control methods are used to carry out complicated tasks of the robots. Therefore, efficient control systems are required for the robots. Approach: This study presented a distributed control system using a Personal Computer (PC and Micro Control Units (MCUs for humanoid robots. Distributed control systems have the advantages that parallel processing using multiple computers is possible and cables in the system can be short. For the control of the humanoid robots, required functions of the control system were discussed. Based on the discussion, the hardware of the system including a PC and MCUs was proposed. The system was designed to carry out the process of the robot control efficiently. The system can be expanded easily by increasing the number of MCU boards. The software of the system for feedback control of the motors and the communication between the computers was proposed. Flexible switching of motor control methods can be achieved easily. Results: Experiments were performed to show the effectiveness of the system. The sampling frequency of the whole system can be about 0.5 kHz and that in local MCUs can be about 10 kHz. Control method of the motor can be changed during the motion in an experiment controlling four joints of the robot. Conclusion: The results of the experiments showed that the distributed control system proposed in this study is effective for humanoid robots.

  2. The Physical Design of Special Chain Pumping Unit%特种链条抽油机结构设计

    Institute of Scientific and Technical Information of China (English)

    王集思; 刘兴德; 卢伟宏

    2016-01-01

    设计一种长冲程、大泵径、低冲次,适合稠油、高粘、多砂等作业工况的特种链条抽油机。该机采用特殊链条结构可实现链节的无油自润滑传动;采用无游梁式换向机构,通过特种销轴和特种链节,实现换向无冲击和换向无受力死点。%Design a kind of special chain pumping unit with the characteristics of long stroke,large pump diameter and low speed,suitable for heavy oil,high viscosity,sand etc.operating mode.This machine USES the special chain structure can realize self-lubrication chain transmission;Adopting no-beam steering,through special pin and special link,achieve the reversing no impact and the reversing no dead point.

  3. Bridging the conservation design and delivery gap for wetland bird habitat maintenance and restoration in the Midwestern United States

    Science.gov (United States)

    Thogmartin, W.E.; Potter, B.; Soulliere, G.

    2011-01-01

    The U.S. Fish and Wildlife Service's adoption of Strategic Habitat Conservation is intended to increase the effectiveness and efficiency of conservation delivery by targeting effort in areas where biological benefits are greatest. Conservation funding has not often been allocated in accordance with explicit biological endpoints, and the gap between conservation design (the identification of conservation priority areas) and delivery needs to be bridged to better meet conservation goals for multiple species and landscapes. We introduce a regional prioritization scheme for North American Wetlands Conservation Act funding which explicitly addresses Midwest regional goals for wetland-dependent birds. We developed decision-support maps to guide conservation of breeding and non-breeding wetland bird habitat. This exercise suggested ~55% of the Midwest consists of potential wetland bird habitat, and areas suited for maintenance (protection) were distinguished from those most suited to restoration. Areas with greater maintenance focus were identified for central Minnesota, southeastern Wisconsin, the Upper Mississippi and Illinois rivers, and the shore of western Lake Erie and Saginaw Bay. The shores of Lakes Michigan and Superior accommodated fewer waterbird species overall, but were also important for wetland bird habitat maintenance. Abundant areas suited for wetland restoration occurred in agricultural regions of central Illinois, western Iowa, and northern Indiana and Ohio. Use of this prioritization scheme can increase effectiveness, efficiency, transparency, and credibility to land and water conservation efforts for wetland birds in the Midwestern United States.

  4. Designed sound and music environment in postanaesthesia care units--a multicentre study of patients and staff.

    Science.gov (United States)

    Thorgaard, Per; Ertmann, Ellen; Hansen, Vibeke; Noerregaard, Anni; Hansen, Vibeke; Spanggaard, Lene

    2005-08-01

    A multicentre study in five postanaesthesia care units (PACUs) was performed to investigate patient and staff opinion of a specially designed music environment (DME), related to geographical location. Patients (325) and staff (91) described their opinion by means of a questionnaire-anonymously in the case of staff. Patients were not asked beforehand for permission to play music. Amongst patients 267 (83%) found the sound environment with DME pleasant or very pleasant, 26 (6%) found it unpleasant, whereas 32 (11%) answered "no opinion". The opinion of the patients did not differ significantly with geographical location. A strong correlation (P<0.05) between a positive attitude towards DME and degree of relaxation and satisfaction with stay was found. The staff had an equally positive attitude towards the DME; but theirs varied significantly with location. The opinion of the staff was more similar concerning the beneficial effect on working conditions and distress, but varied still significantly. The opinion of the staff had no demonstrable impact on that of the patients.

  5. In Silico Testing of an Artificial-Intelligence-Based Artificial Pancreas Designed for Use in the Intensive Care Unit Setting.

    Science.gov (United States)

    DeJournett, Leon; DeJournett, Jeremy

    2016-11-01

    Effective glucose control in the intensive care unit (ICU) setting has the potential to decrease morbidity and mortality rates which should in turn lead to decreased health care expenditures. Current ICU-based glucose controllers are mathematically derived, and tend to be based on proportional integral derivative (PID) or model predictive control (MPC). Artificial intelligence (AI)-based closed loop glucose controllers may have the ability to achieve control that improves on the results achieved by either PID or MPC controllers. We conducted an in silico analysis of an AI-based glucose controller designed for use in the ICU setting. This controller was tested using a mathematical model of the ICU patient's glucose-insulin system. A total of 126 000 unique 5-day simulations were carried out, resulting in 107 million glucose values for analysis. For the 7 control ranges tested, with a sensor error of ±10%, the following average results were achieved: (1) time in control range, 94.2%, (2) time in range 70-140 mg/dl, 97.8%, (3) time in hyperglycemic range (>140 mg/dl), 2.1%, and (4) time in hypoglycemic range (artificial pancreas system for use in the ICU setting. © 2016 Diabetes Technology Society.

  6. Quality of life in children three and nine months after discharge from a paediatric intensive care unit: a prospective cohort study

    Directory of Open Access Journals (Sweden)

    Bos Albert P

    2008-03-01

    Full Text Available Abstract Background Improved survival in children with critical illnesses has led to new disease patterns. As a consequence evaluation of the well being of survivors of Pediatric Intensive Care Units (PICU has become important. Outcome assessment should therefore consist of evaluation of morbidity, functional health and Health Related Quality of Life (HRQoL. Awareness of HRQoL consequences and physical sequelae could lead to changes in support during the acute phase and thereafter. The aim of this study was to evaluate HRQoL in PICU survivors. Methods Prospective follow-up study three and nine months after discharge from a 14-bed tertiary PICU. Eighty-one of 142 eligible, previously healthy children were included from December 2002 through October 2005. HRQoL was assessed with the TNO-AZL Preschool Children Quality of Life Questionnaire (TAPQOL-PF for children aged 1 to 6 years of age, the TNO-AZL Children's Quality of Life Questionnaire Parent Form (TACQOL-PF for children aged 6 to 12 years of age, and the TNO-AZL Children's Quality of Life Questionnaire Child Form (TACQOL-CF for children aged 8 to 15 years of age. The studied patients were compared with age appropriate normative data using non-parametric tests and effect sizes. Results Thirty-one and 27 children, and 55 and 50 parents completed questionnaires respectively three and nine months after discharge. In 1–6 year old children parents reported more lung problems (3 and 9 months, worse liveliness (9 months and better appetite and problem behaviour (3 months; in 6–12 year old children parents reported worse motor functioning (3 months; and 12–15 year old adolescents reported worse motor functioning (3 months. Large effect sizes indicating clinical significant differences in HRQoL with healthy control subjects were found on more domains. Conclusion In this small group of PICU survivors differences in HRQoL with the normative population exist three and nine months after discharge

  7. Design, construction, operation and evaluation of a prototype culm combustion boiler/heater unit. Technical progress report, October 1-December 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1980-02-01

    This report provides a summary of the work performed on the Prototype Culm Combustion Boiler/Heater Unit, Phase I - Engineering Design and Analysis and Limited Phase II - Prototype Plant Construction during the period October 1, 1979 through December 31, 1979. The objectives of the program as well as the technical progress and problem areas encountered are presented. Progress on the components and system engineering studies is described. The Preliminary Design of Prototype Unit Topical Report was submitted. Final design activity is continuing and the progress on drawing preparation and advanced procurement activity is discussed. Based on authorization for a limited amount of Phase II activity, initial Purchase Orders were released authorizing preparation of certified drawings for fabricated equipment required to support the Phase I final design activity. The Purchase Order for site clearance and installation of boiler foundations was awarded and ground breaking ceremonies were held at the Prototype Culm Combustion Boiler site in Paxinos, Pennsylvania, on December 7, 1979.

  8. A design of vehicle controller unit based on MATLAB/SimuLink%基于MATLAB/SimuLink平台的整车控制器设计

    Institute of Scientific and Technical Information of China (English)

    王建军

    2012-01-01

    A kind of software and hardware vehicle control unit design for new energy vehicle based on MATLAB/SimLink IS presented.Model design and its embedded flow implementation , hardware design,BootLoader technique and parameters setting and the whole process of vehicle control unit design are included in this paper.%介绍了一种基于MATLAB/SimuLink平台的新能源汽车用整车控制器的软硬件设计。阐述了基于MATLAB的模型设计及嵌入式实现流程、整车控制器硬件系统的设计、MPC555的BooLoder技术及MATLAB平台下对MPC555目标参数设置。介绍了整个基于MATLAB/SimuLink平台整车控制器的软硬件设计过程。

  9. Planning, Designing, Building, and Moving a Large Volume Maternity Service to a New Labor and Birth Unit: Commentary and Experiences of Experts.

    Science.gov (United States)

    VonBehren, Diane; Killion, Molly M; Burke, Carol; Finkelmeier, Betsy; Zamora, Brigit

    Three teams of perinatal expert nurses participated in planning and designing a new maternity unit, operationalizing the move to the new space, and evaluating care processes and workflows after the move. The hospitals involved were University of California, San Francisco Benioff Children's Hospital, Prentice Women's Hospital of Northwestern Memorial Healthcare in Chicago, IL, and Florida Hospital Orlando, Florida Hospital for Women. Although each team discussed specific details and lessons learned, there is remarkable consistency among the experiences of these teams and with the discussion of the process by the team at Mercy Hospital St. Louis published in this issue of MCN The American Journal of Maternal Child Nursing. Extensive planning, flexibility, involving key stakeholders, evaluating and simulating workflows, and adequate staffing and patient safety on move-day were reported to be essential to success. Reevaluation after settling in to the new unit and making changes as needed were discussed. Being part of the leadership team involved in planning and moving to a new maternity unit in what was likely a once-in-a-lifetime experience was viewed as a career highlight. Their commentary adds to what is known about planning and designing new maternity units, moving into the new space, and adjusting unit operations and care after making the new unit home.

  10. Discussion on how to strengthen human resources training for design units%论设计单位如何加强人力资源管理

    Institute of Scientific and Technical Information of China (English)

    周竹青

    2011-01-01

    Combining with current domestic human resources training status for design units, this thesis analyzes various problems and cause of human resources training for design units, puts forward improving suggestions, and describes corresponding specific measures, so as to guide de- sign units to scientifically carry out human resources training.%结合目前国内设计单位人力培训工作现状,分析了设计单位人力资源培训工作中存在的各种问题及原因,针对性地提出了改进建议,并阐述了相应的具体措施,以指导设计单位科学地进行人力资源培训。

  11. Modelo Crosscultural de Pasantias para Lideres de la Educacion: Cooperacion entre Estados Unidos y Venezuela (Designing an Effective School Administrator Internship Program: United States and Venezuela Cooperation).

    Science.gov (United States)

    Serafin, Ana Gil; Thompson, Eugene W.

    A model was developed of an internship program designed to give valuable cross-cultural experience to school administrators in training at universities in the United States and Venezuela. A naturalistic approach was used to develop the model. Leading school administrators and educational leadership theorists in both countries were interviewed by…

  12. 德士古煤气化装置设计问题探讨%Study on Design of Texaco Coal Gasification Units

    Institute of Scientific and Technical Information of China (English)

    王旭宾

    2001-01-01

    本文对国内德士古煤气化装置运行中暴露出的设计问题进行了探讨。%This paper studies the design problems which are exposed at therunning of Texaco coal gasification units in China.

  13. Project ALPHA (Advanced Learning Program in the Humanities and Arts): Creativity in Filmmaking. A Study Unit Designed for Education of the Gifted in the Humanities and the Arts.

    Science.gov (United States)

    Le Storti, Anthony J.

    Designed for senior high gifted and creative students, the unit focuses on developing creativity in imagery production and technical skills in filmmaking. Five lessons provide information on objectives, materials, and presentation activities for the following topics: color, dialogue, score, angles and shots, film critique, creative imagery, and…

  14. 75 FR 504 - In the Matter of the Review of the Designation of Kahane Chai (aka American Friends of the United...

    Science.gov (United States)

    2010-01-05

    ... Matter of the Review of the Designation of Kahane Chai (aka American Friends of the United Yeshiva... Judea Police aka Judean Congress aka Kach aka Kahane aka Kahane Lives aka Kahane Tzadak aka Kahane.org... to Section 219 of the Immigration and Nationality Act, as amended Based upon a review of...

  15. Design, evaluation and recommedation effort relating to the modification of a residential 3-ton absorption cycle cooling unit for operation with solar energy

    Science.gov (United States)

    Merrick, R. H.; Anderson, P. P.

    1973-01-01

    The possible use of solar energy powered absorption units to provide cooling and heating of residential buildings is studied. Both, the ammonia-water and the water-lithium bromide cycles, are considered. It is shown that the air cooled ammonia water unit does not meet the criteria for COP and pump power on the cooling cycle and the heat obtained from it acting as a heat pump is at too low a temperature. If the ammonia machine is water cooled it will meet the design criteria for cooling but can not supply the heating needs. The water cooled lithium bromide unit meets the specified performance for cooling with appreciably lower generator temperatures and without a mechanical solution pump. It is recommeded that in the demonstration project a direct expansion lithium bromide unit be used for cooling and an auxiliary duct coil using the solar heated water be employed for heating.

  16. WellStar Paulding Hospital intensive care unit case study: achieving a research-based, patient-centered design using a collaborative process.

    Science.gov (United States)

    Burns, Georgeann B; Hogue, Vicky

    2014-01-01

    This article describes the processes and tools used by WellStar Paulding Hospital to plan and design a new intensive care unit (ICU) as part of a 108-bed replacement hospital on a new site. Seeking to create a culture of safety centered around patient care, quality, and efficiency, the team used multiple external resources to increase their effectiveness as participants in the design process and to ensure that the new ICU achieves the functional performance goals identified at the beginning of planning and design. Specific focus on evidence-based design was assisted through participation in the Center for Health Design's Pebble Project process as well as the Joint Commission International Safe Health Design Learning Academy Pilot Program.

  17. PICU婴儿脓毒症及严重脓毒症临床特征及预后危险因素分析%Sepsis and severe sepsis in PICU infant: analysis of risk factors and clinical feature

    Institute of Scientific and Technical Information of China (English)

    李璧如; 安康; 曹清; 赵醴; 钱娟; 王莹

    2013-01-01

    目的 分析PICU婴儿脓毒症、严重脓毒症的临床特征,探讨影响其预后的危险因素.方法 对2006年1月至2011年12月我院PICU收治的141例脓毒症患儿运用回顾性病例对照(存活组与死亡组)的研究策略,以患儿入院日为研究起点,死亡或出院为终点,进行临床特点分析.并选择性别、年龄、是否有基础疾病、脓毒症严重程度、脏器受累数、入PICU当天的危重病评分、血生化指标(乳酸、白蛋白、血糖)、血气指标(碱剩余、碳酸氢根、pH值)、是否休克、培养阳性等14个变量,建立Logistic回归模型,分析预后的危险因素.结果 141例患儿的年龄1~12个月,其中脓毒症72例,严重脓毒症69例,死亡29例,病死率为20.6%.29例死亡患儿中,13例有基础疾病.脓毒症和严重脓毒症患儿的感染部位均以肺部为主,分别占47.2%(34/72)、47.8%(33/69);血培养均有34例阳性,分别占47.2% (34/72)、49.3% (34/69).单因素分析显示,性别、基础疾病、年龄、脓毒症严重程度、休克、脏器受累数、危重病例评分、血乳酸、血气pH值、碱剩余、碳酸氢根与脓毒症死亡有关.经逐步引入剔除法,建立Logistic回归模型,仍然与死亡相关的因素包括脓毒症严重程度(OR=22.5,95%CI=5.089,99.475)和脏器受累数(OR=3.305,95%CI=2.152,5.075).结论 婴儿脓毒症严重程度越重和器官受累数越多,死亡风险越大.%Objective To analyze the clinical characteristics of PICU infant with sepsis,severe sepsis,and to explore the impact of prognostic factors.Methods We conducted a retrospective study of 141 cases (from January 2006 to December 2011) who were diagnosed as sepsis and severe sepsis to identify the clinical characteristics.There were 14 variables of the PICU admission day which concluded gender,age,underlying diseases,sepsis severity,organ involvement,critical score,blood biochemistry (lactate,albumin,glucose),blood gas (base excess

  18. 单精度浮点运算单元的FPGA设计与实现%Design and Implement of Single Precision Floating-Point Unit on FPGA

    Institute of Scientific and Technical Information of China (English)

    张素萍; 李红刚; 张慧坚; 董定超

    2011-01-01

    This paper analyzes the principle and operation process of the floating-point unit; studies the architecture of Floating-Point Unit. To solve the deficiency which FPU design depended on software. We propose a project of the FPU design which is suitable for FPGA.This approach enhances the portability and improvement of the system and higher calculating speed. The design unit is simulated, meeting the requirements of design and realizing logic synthesis in FPGA with the model Cyclone Ⅱ EP2C35F672C6. The result shows that the operating frequency is 47. 4MHZ to meet all requirements of the design.%针对以前浮点运算依靠软件实现的弊端,提出采用自顶向下的设计方法,模块化的设计思想来实现FPU整个设计,这种设计方法增强了系统的可移植性及可改进性;系统在CycloneⅡ EP2C35FC684C6的FPGA上综合实现,验证结果表明,在满足各项功能要求的前提下,其系统最高时钟频率可达到47.4MHZ,提高了浮点运算单元的处理速度.

  19. Scale-up of mild gasification to be a process development unit mildgas 24 ton/day PDU design report. Final report, November 1991--July 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    From November 1991 to April 1996, Kerr McGee Coal Corporation (K-M Coal) led a project to develop the Institute of Gas Technology (IGT) Mild Gasification (MILDGAS) process for near-term commercialization. The specific objectives of the program were to: design, construct, and operate a 24-tons/day adiabatic process development unit (PDU) to obtain process performance data suitable for further design scale-up; obtain large batches of coal-derived co-products for industrial evaluation; prepare a detailed design of a demonstration unit; and develop technical and economic plans for commercialization of the MILDGAS process. The project team for the PDU development program consisted of: K-M Coal, IGT, Bechtel Corporation, Southern Illinois University at Carbondale (SIUC), General Motors (GM), Pellet Technology Corporation (PTC), LTV Steel, Armco Steel, Reilly Industries, and Auto Research.

  20. Designing and Implementing an OVERFLOW Reader for ParaView and Comparing Performance Between Central Processing Units and Graphical Processing Units

    Science.gov (United States)

    Chawner, David M.; Gomez, Ray J.

    2010-01-01

    In the Applied Aerosciences and CFD branch at Johnson Space Center, computational simulations are run that face many challenges. Two of which are the ability to customize software for specialized needs and the need to run simulations as fast as possible. There are many different tools that are used for running these simulations and each one has its own pros and cons. Once these simulations are run, there needs to be software capable of visualizing the results in an appealing manner. Some of this software is called open source, meaning that anyone can edit the source code to make modifications and distribute it to all other users in a future release. This is very useful, especially in this branch where many different tools are being used. File readers can be written to load any file format into a program, to ease the bridging from one tool to another. Programming such a reader requires knowledge of the file format that is being read as well as the equations necessary to obtain the derived values after loading. When running these CFD simulations, extremely large files are being loaded and having values being calculated. These simulations usually take a few hours to complete, even on the fastest machines. Graphics processing units (GPUs) are usually used to load the graphics for computers; however, in recent years, GPUs are being used for more generic applications because of the speed of these processors. Applications run on GPUs have been known to run up to forty times faster than they would on normal central processing units (CPUs). If these CFD programs are extended to run on GPUs, the amount of time they would require to complete would be much less. This would allow more simulations to be run in the same amount of time and possibly perform more complex computations.

  1. Circumstances surrounding dying in the paediatric intensive care unit

    Directory of Open Access Journals (Sweden)

    Plötz Frans B

    2006-08-01

    Full Text Available Abstract Background Death is inevitable in the paediatric intensive care unit (PICU. We aimed to describe the circumstances surrounding dying in a PICU. Method The chart records of all patients less than 18 years of age who died at the PICU between January first 2000 and July first 2005 were retrospectively analyzed. Information regarding sex, age, length of stay, admission, diagnosis, and the way a patient died was registered. Post mortem information regarding natural versus unnatural death, autopsy and donation was obtained. Non-survivors were allocated in five groups: do-not-resuscitate (DNR, withholding and/or withdrawal of therapy (W/W, failed cardiopulmonary resuscitation (failed CPR, brain death (BD, and terminal organ failure (TOF. Results During the study period 87 (4.4% of the 1995 admitted patients died. Non-survivors were more often admitted during the day (54% and the week (68%. W/W was found in 27.6%, TOF in 26.4%, BD in 23.0%, failed CPR in 18.4%, and DNR in 4.6%. Forty-three percent died in the first two days, of which BD (40.5% and failed CPR (37.8% were most common. Seventy-five children (86% died due to a natural cause. Autopsy permission was obtained in 19 of 54 patients (35%. The autopsies confirmed the clinical diagnosis in 11 patients, revealed new information in 5 patients, and in 3 patients the autopsy did not provide additional information. Nine patients were medically suitable for organ donation and 24 patients for tissue donation, whereas consent was only obtained in 2 cases in both groups. Conclusion We observed that 43% of the patients died within the first two days of admission due to BD and failed CPR, whereas after 4 days most patients died after W/W. Autopsy remains an useful tool to confirm clinical diagnoses or to provide new information. Only a small percentage of the deceased children is suitable for organ donation.

  2. [Surveying the status of continuous blood purification technology application in Chinese pediatric intensive care unit].

    Science.gov (United States)

    Li, Leilei; Lu, Guoping

    2014-03-01

    To learn application status of continuous blood purification (CBP) in pediatric intensive care unit (PICU), to provide reference to promote the development of CBP technology. The survey of CBP application was conducted using questionnaire in 40 hospitals providing intensive care, which included children's hospitals and the pediatric sections of general hospitals from 28 provinces/municipalities/autonomous regions in China during March to July of 2012. Totally 38 hospital replied, 25 hospitals carried out CBP technology, first carried out in 1997, the median year was 2008, 21 hospitals' PICU could independently carry out CBP device, 18 hospitals had the nurses who could professionally operate, routinely maintain the device. Continuous veno-venous hemodiafiltration was the largest implementation mode of CBP, accounting for 51.9%. Twenty-three hospitals used ordinary heparin, and 2 hospitals used low molecular weight heparin; 21 hospitals chose activated partial thromboplastin time as the coagulation testing, due to lack of equipment, only four hospitals chose activated clotting time as coagulation testing. Only 3 hospitals could apply before and after dilution joint technology. Kidney failure is still the disease accounting for the highest proportion of diseases requiring CBP application, accounting for 38.1%, followed by sepsis, 19.1%, drug poisoning 16.7%. CBP started 10 years ago, and got attention and promotion nearly five years ago in China, but the associated personnel, equipment were inadequate, anticoagulation, before and after dilution and other technical applications were not complete enough, high volume hemofiltration mode was seldom used.

  3. Long-term consequences of an intensive care unit stay in older critically ill patients: design of a longitudinal study

    Directory of Open Access Journals (Sweden)

    Hantikainen Virpi

    2011-09-01

    Full Text Available Abstract Background Modern methods in intensive care medicine often enable the survival of older critically ill patients. The short-term outcomes for patients treated in intensive care units (ICUs, such as survival to hospital discharge, are well documented. However, relatively little is known about subsequent long-term outcomes. Pain, anxiety and agitation are important stress factors for many critically ill patients. There are very few studies concerned with pain, anxiety and agitation and the consequences in older critically ill patients. The overall aim of this study is to identify how an ICU stay influences an older person's experiences later in life. More specific, this study has the following objectives: (1 to explore the relationship between pain, anxiety and agitation during ICU stays and experiences of the same symptoms in later life; and (2 to explore the associations between pain, anxiety and agitation experienced during ICU stays and their effect on subsequent health-related quality of life, use of the health care system (readmissions, doctor visits, rehabilitation, medication use, living situation, and survival after discharge and at 6 and 12 months of follow-up. Methods/Design A prospective, longitudinal study will be used for this study. A total of 150 older critically ill patients in the ICU will participate (ICU group. Pain, anxiety, agitation, morbidity, mortality, use of the health care system, and health-related quality of life will be measured at 3 intervals after a baseline assessment. Baseline measurements will be taken 48 hours after ICU admission and one week thereafter. Follow-up measurements will take place 6 months and 12 months after discharge from the ICU. To be able to interpret trends in scores on outcome variables in the ICU group, a comparison group of 150 participants, matched by age and gender, recruited from the Swiss population, will be interviewed at the same intervals as the ICU group. Discussion Little

  4. 纤维支气管镜术在儿童重症监护病房中应用的围手术期护理%Perioperative nursing of children patients in PICU during fiberoptic bronchoscopy

    Institute of Scientific and Technical Information of China (English)

    陈灵芝; 任海丽; 李磊; 赵丽清; 佟志颖; 董建英

    2013-01-01

    Objective To explore the perioperative nursing experience during the application of fiberoptic bronchoscopy in PICU,in order to improve nursing processes and advocate excellent nursing service.Methods Considering the features of children' s anatomy and physiology and severe heart and lung diseases,1088 clinical diagnosis and treatment documents of 848 children patients cured in our hospital were reviewed and analyzed so as to summarize the essentials and process of perioperative nursing.Results There were no serious complications and other adverse consequences in all of 848 children patients.77% (651/848) children patients who were diagnosed with severe pneumonia according to the preoperative clinical symptoms and imaging were cured or got better by using lung lavage on fiberoptic bronchoscopy and others clinical treatment,the foreign bodies of 5% (45/848) children patients were successftlly removed; and There were no any stents loss or displacement in all children patients.There were the transient decrease in heart rate,the phenomenon that SpO2 decreased to 80% or less and facial cyanosis in 14% (119/848) children patients when operating fiberoptic bronchoscopy,and these children patients had no serious consequences and achieved remission of symptoms after immediately exiting fiberoptic bronchoscopy by doctors under the nurses reminds who detected these abnormalities in time.Conclusions Sufficient,proper,and scientific perioperative nursing plays an important role in reducing operative risk,postoperative complications as well as reducing operation time.%目的 探讨纤维支气管镜的多项诊疗技术在儿童重症监护病房应用中的围手术期护理经验,完善护理流程,倡导优质护理服务.方法 选取848例患儿的1 088次诊疗临床资料进行回顾性分析,结合儿童的生理解剖和重症心、肺疾病特点,归纳总结围手术期的护理要点及流程.结果 本研究848例患儿未出现1例术中严重并

  5. Delphi type methodology to develop consensus on the future design of EMS systems in the United Kingdom

    OpenAIRE

    Hassan, T.; Barnett, D.

    2002-01-01

    Design: A Delphi questionnaire design with two rounds to gain a consensus of opinion. Investigation of four aspects of EMS design is reported—type of response to a priority based dispatch category, transportation options, enhancement of paramedic skills, and structure of a first responder system.

  6. Design-Basis Flood Estimation for Site Characterization at Nuclear Power Plants in the United States of America

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, Rajiv; Hibler, Lyle F.; Coleman, Andre M.; Ward, Duane L.

    2011-11-01

    The purpose of this document is to describe approaches and methods for estimation of the design-basis flood at nuclear power plant sites. Chapter 1 defines the design-basis flood and lists the U.S. Nuclear Regulatory Commission's (NRC) regulations that require estimation of the design-basis flood. For comparison, the design-basis flood estimation methods used by other Federal agencies are also described. A brief discussion of the recommendations of the International Atomic Energy Agency for estimation of the design-basis floods in its member States is also included.

  7. Design

    DEFF Research Database (Denmark)

    Volf, Mette

    This publication is unique in its demystification and operationalization of the complex and elusive nature of the design process. The publication portrays the designer’s daily work and the creative process, which the designer is a part of. Apart from displaying the designer’s work methods...... and design parameters, the publication shows examples from renowned Danish design firms. Through these examples the reader gets an insight into the designer’s reality....

  8. Design and Application of a Power Unit to Use Plug-In Electric Vehicles as an Uninterruptible Power Supply

    Directory of Open Access Journals (Sweden)

    Gorkem Sen

    2016-03-01

    Full Text Available Grid-enabled vehicles (GEVs such as plug-in electric vehicles present environmental and energy sustainability advantages compared to conventional vehicles. GEV runs solely on power generated by its own battery group, which supplies power to its electric motor. This battery group can be charged from external electric sources. Nowadays, the interaction of GEV with the power grid is unidirectional by the charging process. However, GEV can be operated bi-directionally by modifying its power unit. In such operating conditions, GEV can operate as an uninterruptible power supply (UPS and satisfy a portion or the total energy demand of the consumption center independent from utility grid, which is known as vehicle-to-home (V2H. In this paper, a power unit is developed for GEVs in the laboratory to conduct simulation and experimental studies to test the performance of GEVs as a UPS unit in V2H mode at the time of need. The activation and deactivation of the power unit and islanding protection unit are examined when energy is interrupted.

  9. Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach Nuclear Power Plant, Units 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Laudenbach, D.H.

    1979-03-01

    The technical evaluation is presented for the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach nuclear power plant, Units 1 and 2. Design basis criteria used to evaluate the acceptability of the system included operator action, system testability, single failure criterion, and seismic Category I and IEEE Std-279-1971 criteria. This report is supplied as part of the Selected Electrical, Instrumentation, and Control Systems Issues Support Program being conducted for the U.S. Nuclear Regulatory Commission by Lawrence Livermore Laboratory.

  10. 空间辐射探测器滤波电路的设计%Design of Filter Circuit in High Voltage Unit of Particle Detector

    Institute of Scientific and Technical Information of China (English)

    施伟红; 于向前; 陈鸿飞; 邹鸿; 邹积清; 刘建文; 崔战国; 邵思霈

    2012-01-01

    To meet high stability, low ripple requirements of High Voltage Unit in Particle radiation detectors, to design a hybrid LC and RC filter circuit to reduce power supply ripple. Through the theoretical analysis, Pspice simulation and test,the results are verified. According to this design,a High Voltage Unit was made in a high -energy particle detector on a Satelite, output voltage ripple coefficient is small, met the design purposes. Test proved that this circuit design, simple, efficient, can provide a reference for this kind of circuit design.%为满足粒子辐射探测器高压电源高稳定、低纹波的要求,设计一种LC和RC混合滤波电路来降低电源纹波,并进行理论分析、PSpice仿真和试验对结果进行验证.按照这种设计实现的某型号卫星高能粒子探测器的高压电源,输出电压稳定、纹波系数小,达到设计目的.试验证明这种电路设计简单、高效,可为相关电路设计提供参考.

  11. Design, construction and testing of a low-cost automated (68)Gallium-labeling synthesis unit for clinical use.

    Science.gov (United States)

    Heidari, Pedram; Szretter, Alicia; Rushford, Laura E; Stevens, Maria; Collier, Lee; Sore, Judit; Hooker, Jacob; Mahmood, Umar

    2016-01-01

    The interest in (68)Gallium labeled PET probes continues to increase around the world. Widespread use in Europe and Asia has led to great interest for use at numerous sites in the US. One barrier to entry is the cost of the automated synthesis units for relatively simple labeling procedures. We describe the construction and testing of a relatively low-cost automated (68)Ga-labeling unit for human-use. We provide a guide for construction, including part lists and synthesis timelists to facilitate local implementation. Such inexpensive systems could help increase use around the globe and in the US in particular by removing one of the barriers to greater widespread availability. The developed automated synthesis unit reproducibly synthesized (68)Ga-DOTATOC with average yield of 71 ± 8% and a radiochemical purity ≥ 95% in a synthesis time of 25 ± 1 minutes. Automated product yields are comparable to that of manual synthesis. We demonstrate in-house construction and use of a low-cost automated synthesis unit for labeling of DOTATOC and similar peptides with (68)Gallium.

  12. Unit Testing Using Design by Contract and Equivalence Partitions, Extreme Programming and Agile Processes in Software Engineering

    DEFF Research Database (Denmark)

    Madsen, Per

    2003-01-01

    Extreme Programming [1] and in particular the idea of Unit Testing can improve the quality of the testing process. But still programmers need to do a lot of tiresome manual work writing test cases. If the programmers could get some automatic tool support enforcing the quality of test cases then t...... then the overall quality of the software would improve significantly....

  13. Effectiveness of classroom based crew resource management training in the intensive care unit: study design of a controlled trial.

    NARCIS (Netherlands)

    Kemper, P.F.; Bruijne, M. de; Dyck, C. van; Wagner, C.

    2011-01-01

    Background: Crew resource management (CRM) has the potential to enhance patient safety in intensive care units (ICU) by improving the use of non-technical skills. However, CRM evaluation studies in health care are inconclusive with regard to the effect of this training on behaviour and organizationa

  14. 78 FR 15802 - United States-Israel Free Trade Area Implementation Act; Re-Designation of Qualifying Industrial...

    Science.gov (United States)

    2013-03-12

    ... Qualifying Industrial Zones AGENCY: Office of the United States Trade Representative. ACTION: Notice. SUMMARY... industrial zones (QIZs) encompassing portions of Israel and Jordan or Israel and Egypt are eligible to... certain tariff treatment for articles of the West Bank, the Gaza Strip, and qualifying industrial...

  15. 20 CFR 631.30 - Designation or creation and functions of a State dislocated worker unit or office, and rapid...

    Science.gov (United States)

    2010-04-01

    ..., regional or industrywide projects; (2) Work with employers and labor organizations in promoting labor... the rapid response team (section 311(b)(3)(D)); (9) Fully consult with labor organizations where... unit or office may be an existing organization or new organization formed for this purpose (section 311...

  16. Effectiveness of classroom based crew resource management training in the intensive care unit: study design of a controlled trial.

    NARCIS (Netherlands)

    Kemper, P.F.; Bruijne, M. de; Dyck, C. van; Wagner, C.

    2011-01-01

    Background: Crew resource management (CRM) has the potential to enhance patient safety in intensive care units (ICU) by improving the use of non-technical skills. However, CRM evaluation studies in health care are inconclusive with regard to the effect of this training on behaviour and

  17. Unit Testing Using Design by Contract and Equivalence Partitions, Extreme Programming and Agile Processes in Software Engineering

    DEFF Research Database (Denmark)

    Madsen, Per

    2003-01-01

    Extreme Programming [1] and in particular the idea of Unit Testing can improve the quality of the testing process. But still programmers need to do a lot of tiresome manual work writing test cases. If the programmers could get some automatic tool support enforcing the quality of test cases...

  18. Design of a unit to produce hot distilled water for the same power consumption as a water heater

    Science.gov (United States)

    Bambenek, R. A.; Nuccio, P. P.

    1973-01-01

    Unit recovers 97% of water contained in pretreated waste water. Some factors are: cleansing agent prevents fouling of heat transfer surface by highly concentrated waste; absence of dynamic seals reduces required purge gas flow rate; and recycle loop maintains constant flushing process to carry cleansing agent across evaporation surface.

  19. 75 FR 53266 - United States Army Restricted Area, Designated Portions of Eagle Bay and Eagle River, Fort...

    Science.gov (United States)

    2010-08-31

    ... Portions of Eagle Bay and Eagle River, Fort Richardson, AK AGENCY: United States Army Corps of Engineers... status of a portion of Eagle River within the boundaries of Fort Richardson, Alaska as well as an adjacent portion of Eagle Bay in the Knik Arm. More specifically, the restricted area is to include...

  20. Reproducibility of mandibular third molar assessment comparing two cone beam CT units in a matched pairs design.

    Science.gov (United States)

    Matzen, L H; Hintze, H; Spin-Neto, R; Wenzel, A

    2013-01-01

    The aim of this study was to evaluate the reproducibility of the third molar assessment, comparing five observers and two cone beam CT (CBCT) units. 28 patients, each with two impacted mandibular third molars, were included. Each patient was randomly examined with a Scanora(®) 3D (Soredex, Helsinki, Finland) CBCT unit in one mandibular third molar region and with a Cranex(®) 3D (Soredex) CBCT unit in the other region. Five observers with varying CBCT experience assessed all third molars and recorded the following variables: number and morphology of the roots, relation to the mandibular canal in two directions, shape of the canal and whether there was a direct contact between the roots of the molar and the mandibular canal. The radiographic assessments were compared pairwise among all observers for all variables. Wilcoxon's signed-rank test was used to test the differences in observer accordance percentages among the recorded variables in the images from the two units, and kappa statistics expressed interobserver reproducibility. The mean percentages for observer accordance ranged from 65.4 to 92.9 for Scanora 3D and 60.3 to 94.8 for Cranex 3D. There was no significant difference between the observer accordance in the two CBCT units (p > 0.05), except for assessing root flex in the mesiodistal direction, for which the observer accordance was higher for Scanora 3D (p third molar assessment. Observer variation existed, and experienced radiologists demonstrated the highest interobserver reproducibility for canal-related variables.

  1. Design, construction, operation and evaluation of a Prototype Culm Combustion Boiler/Heater Unit. Quarterly technical progress report, October 1-December 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1980-02-01

    This report provides a summary of the work performed on the Prototype Culm Combustion Boiler/Heater Unit, Phase I - Engineering Design and Analysis and Limited Phase II - Prototype Plant Construction during the period October 1, 1979 through December 31, 1979. The objectives of the program as well as the technical progress and problem areas encountered during the reporting period are presented. Progress on the components and system engineering studies is described. The Preliminary Design of Prototype Unit Topical Report was submitted during this reporting period. Final design activity is continuing and the progress on drawing preparation and advanced procurement activity is discussed. Based on authorization for a limited amount of Phase II activity, initial purchase orders were released authorizing preparation of certified drawings for fabricated equipment required to support the Phase I final design activity. The Purchase Order for site clearance and installation of boiler foundations was awarded during this reporting period and ground breaking ceremonies were held at the Prototype Culm Combustion Boiler site in Paxinos, Pennsylvania on December 7, 1979.

  2. Dr Julia King CBE FREng, Chief Executive Designate, Institute of Physics (United Kingdom), visiting the NA48 experiment.

    CERN Document Server

    Patrice Loïez

    2002-01-01

    Photo 02: Visiting the NA48 experiment, Dr Julia King, Chief Executive Designate, Institute of Physics (Britain and Ireland) (right) with A. Ceccucci and K. Peach. Photo 05: Visiting the NA48 experiment, Dr Julia King, Chief Executive Designate, Institute of Physics (Britain and Ireland) (centre) with A. Ceccucci and C. Lazzeroni. Photo 08: Visiting the NA48 experiment, Dr Julia King, Chief Executive Designate, Institute of Physics (Britain and Ireland) (second from left) with (left to right) R. Barlow, J. Wood, N. McCubbin, K. Peach, A. Ceccucci, C. Lazzeroni, M. Patel and D. Munday.

  3. Design, construction, operation, and evaluation of a prototype culm-combustion boiler/heater unit. Quarterly technical progress report, October 1-December 31, 1980

    Energy Technology Data Exchange (ETDEWEB)

    1981-02-01

    This report provides a summary of the work performed on the Prototype Culm Combustion Boiler/Heater Unit, Phase I - Engineering Design and Analysis and Phase II - Prototype Plant Construction during the period October 1, 1980 through December 31, 1980. The objectives of the program as well as the technical progress and problem areas encountered during the reporting period are presented. The final detail design effort was completed and the final design report submitted. Progress on procurement activity authorized by full Phase II release on March 20, 1980, is discussed. Following approval by DOE, a purchase order was placed with the Norflor Construction Corporation for the prototype plant construction which began in November. Construction of the access roadway installation of the electric power, sewer and water lines was completed during this reporting period. Boiler construction continued.

  4. 中国儿童重症监护病房体外膜肺氧合技术应用现状调查%Surveying the status of extracorporeal membrane oxygenation application in Chinese pediatric intensive ;care unit

    Institute of Scientific and Technical Information of China (English)

    闫钢风; 陆国平; 张晨美; 洪小杨; 许煊; 钱素云; 王莹; 刘春峰

    2016-01-01

    Objective To investigate the application of extracorporeal membrane oxygenation ( ECMO) in pediatric intensive care unit( PICU) in China. Methods Data were collected by questionnaire in PICU of tertiary hospitals,which included children′s hospitals and the pediatric sections of general hospitals from 26 provinces/municipalities/autonomous regions in China from March to August 2015. Results Total 38 hospitals were enrolled, including 28 children hospitals and 10 general hospitals. Six PICU carried out ECMO technology. Fourteen PICU prepared to perform this technology. Nine had ECMO team, and 8 had received ECMO training. Ten PICU had a total of 12 ECMO machines. Sixty-three patients were supported with non-open chest ECMO, 49 ( 77. 8%) of which were decannulated from ECMO successfully, and 36 (57. 1%) survived. Twelve neonates were enrolled,including 10 patients with respiratory failure and 2 with cardiac failure,5 of them survived to discharge. Of 51 pediatric patients received ECMO,28 were supported for cardiac failure,21 for respiratory failure,and 2 for extracorporeal cardiopulmonary resuscitation,31 cases (60. 8%) survived to discharge. Conclusion ECMO technology is still at the initial stage. More efforts are needed to improve the relative equipment,ECMO team and ECMO training in China.%目的:了解中国PICU体外膜肺氧合( ECMO)技术开展及ECMO疗效情况。方法采用问卷调查方式,2015年3月至2015年8月对全国三级甲等医院PICU进行调查。结果共调查了38家儿童医院或综合医院的PICU,其中儿童医院28家,综合医院10家。10家医院的PICU拥有12台ECMO设备;能开展ECMO技术的单位6家,准备开展ECMO技术的单位14家;接受过ECMO培训的医院8家。共有63例患儿在 PICU 内接受非开胸 ECMO 治疗,成功撤离 ECMO 者49例,有效率77.8%;36例存活,存活率57.1%。儿童患者(大于28 d)51例,其中呼吸系统疾病21例,心脏疾病28例,心肺衰竭2例;存活出院31

  5. Biological Shielding Design Effectiveness of the Brachytherapy Unit at the Korle Bu Teaching Hospital in Ghana Using Mcnp5 Monte Carlo Code

    Directory of Open Access Journals (Sweden)

    C.C. Arwui

    2011-05-01

    Full Text Available Design objectives for brachytherapy treatment facilities require sufficient shielding to reduce primary and scatter radiation to design limit in order to limit exposure to patients, staff and the general public. The primary aim of this study is to verify whether shielding of the brachytherapy unit at the Korle Bu teaching Hospital in Ghana provides adequate protection in order to assess any radiological health and safety impact and also test the suitability of other available sources. The study evaluates the effectiveness of the biological shielding design of a Cs-137 brachytherapy unit at the Korle-Bu Teaching Hospital in Ghana using MCNP5. The facility was modeled based on the design specifications for LDR Cs-137, MDR Cs-137, HDR Co-60 and HDR Ir-192 treatment modalities. The estimated dose rate ranged from (0.01-0.15 μSv/h and (0.37-3.05 μSv/h for the existing initial and decayed activities of LDR Cs-137 for the public and controlled areas respectively, (0.03-0.57 μSv/h and (1.53-8.06 μSv/h for MDR Cs-137, (7.47-59.46 μSv/h and (144.87-178.74 μSv/h for HDR Co- 60, (0.13-6.95 μSv/h and (19.47-242.98 μSv/h for HDR Ir-192 for the public and controlled areas respectively. The results were verified by dose rates measurement for the current LDR setup at the Brachytherapy unit and agreed quiet well. It was also compared with the reference values of 0.5 μSv/h for public areas and 7.5 μSv/h for controlled areas respectively. It can be concluded that the shielding is adequate for the existing source.

  6. Detector Unit

    CERN Multimedia

    1960-01-01

    Original detector unit of the Instituut voor Kernfysisch Onderzoek (IKO) BOL project. This detector unit shows that silicon detectors for nuclear physics particle detection were already developed and in use in the 1960's in Amsterdam. Also the idea of putting 'strips' onto the silicon for high spatial resolution of a particle's impact on the detector were implemented in the BOL project which used 64 of these detector units. The IKO BOL project with its silicon particle detectors was designed, built and operated from 1965 to roughly 1977. Detector Unit of the BOL project: These detectors, notably the ‘checkerboard detector’, were developed during the years 1964-1968 in Amsterdam, The Netherlands, by the Natuurkundig Laboratorium of the N.V. Philips Gloeilampen Fabrieken. This was done in close collaboration with the Instituut voor Kernfysisch Onderzoek (IKO) where the read-out electronics for their use in the BOL Project was developed and produced.

  7. An Undergraduate Design Experience in Digital Logic Design Course of Special Purpose Arithmetic Logic Unit Using Multisim, Ultiboard and Print Circuit Board

    Science.gov (United States)

    Al-Haija, Qasem Abu; Al-Amri, Hasan; Al-Nashri, Mohamed; Al-Muhaisen, Sultan

    2013-01-01

    Project-Based Curriculum (PBC) is considered one of the most powerful methods in the engineering education where each course or courses-cluster is assigned a design project which considers a series of inter-related concepts that have been shown theoretically for the students. Using this approach, the student will gain the required knowledge in an…

  8. Early Mobilization Reduces Duration of Mechanical Ventilation and Intensive Care Unit Stay in Patients With Acute Respiratory Failure.

    Science.gov (United States)

    Lai, Chih-Cheng; Chou, Willy; Chan, Khee-Siang; Cheng, Kuo-Chen; Yuan, Kuo-Shu; Chao, Chien-Ming; Chen, Chin-Ming

    2017-05-01

    To evaluate the effects of a quality improvement program to introduce early mobilization on the outcomes of patients with mechanical ventilation (MV) in the intensive care unit (ICU). A retrospective observational study. Nineteen-bed ICU at a medical center. Adults patients with MV (N=153) admitted to a medical ICU. A multidisciplinary team (critical care nurse, nursing assistant, respiratory therapist, physical therapist, patient's family) initiated the protocol within 72 hours of MV when patients become hemodynamically stable. We did early mobilization twice daily, 5d/wk during family visits (30min each time), and cooperated with family, if possible. MV duration, rate of successful weaning, and length of ICU and hospital stay. We enrolled 63 patients in the before protocol group and 90 in the after protocol group. The 2 groups were well matched in age, sex, body height, body weight, body mass index, disease severity, cause of intubation, number of comorbidities, and most underlying diseases. After protocol group patients had shorter MV durations (4.7d vs 7.5d; PICU stays (6.9d vs 9.9d; P=.001) than did before protocol group patients. Early mobilization was negatively associated with the duration of MV (β=-.269; PICU shortened MV durations and ICU stays. A multidisciplinary team that includes the patient's family can work together to improve the patient's clinical outcomes. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. [Parents of a critically ill child - what do they expect from the team of the pediatric intensive care unit?].

    Science.gov (United States)

    Spitz-Köberich, Christine; Barth, Michael; Spirig, Rebecca

    2010-10-01

    Having an ill child that is being treated in a pediatric intensive care unit (PICU) is tremendously stressful for the parents, both physically and emotionally. To help them cope with the circumstances they find themselves in, parents often develop expectations which are addressed to the team of the PICU, and which they find important to be fulfilled. Many of these expectations are culturally shaped. At present, there exist no data from German speaking area. Thus, this qualitative study was undertaken to fill this gap. Episodic interviews were conducted with five mothers and two fathers. Using the content analysis technique described by Mayring, one main category and six subcategories emerged from the data. "Concering about the sick child" was of particular importance for the parents. Their own expectations were reflected in the six subcategories: "Knowing that the child is receiving good care", "Being with the child", "Being involved", "Experiencing care for oneself and one's child", "Being informed" and "Experiencing continuity". These results are congruent with prior research reported in the international literature. Having a desire for a continuous medical support and the clear separation of roles between physicians and nurses are new findings from this investigation which have not been described previously.

  10. Coverage Range and Cost Comparison of Remote Antenna Unit Designs for In-building Radio over Fiber Technology

    Directory of Open Access Journals (Sweden)

    Razali Ngah

    2008-05-01

    Full Text Available Future communication needs to be ubiquitous, broadband, convergent, and seamless. Radio over fiber (RoF technology is one of the most important enabler in access network for the technologies. Adoption of RoF faces bottleneck in optoelectronics, that they are still expensive, high power consumption, and limited in bandwidth. To solve the problem, transceiver in remote antenna unit (RAU is developed, i.e. electroabsorption transceiver (EAT and asymmetric Fabry-Perot modulator (AFPM. This paper compares their coverage range and cost in providing WCDMA and WLAN services. Needed gain of RF amplifier for supporting picocell is also discussed.

  11. Design of a microprocessor-based Control, Interface and Monitoring (CIM unit for turbine engine controls research

    Science.gov (United States)

    Delaat, J. C.; Soeder, J. F.

    1983-01-01

    High speed minicomputers were used in the past to implement advanced digital control algorithms for turbine engines. These minicomputers are typically large and expensive. It is desirable for a number of reasons to use microprocessor-based systems for future controls research. They are relatively compact, inexpensive, and are representative of the hardware that would be used for actual engine-mounted controls. The Control, Interface, and Monitoring Unit (CIM) contains a microprocessor-based controls computer, necessary interface hardware and a system to monitor while it is running an engine. It is presently being used to evaluate an advanced turbofan engine control algorithm.

  12. Conceptual design and cost analysis of hydraulic output unit for 15 kW free-piston Stirling engine

    Science.gov (United States)

    White, M. A.

    1982-01-01

    A long-life hydraulic converter with unique features was conceptually designed to interface with a specified 15 kW(e) free-piston Stirling engine in a solar thermal dish application. Hydraulic fluid at 34.5 MPa (5000 psi) is produced to drive a conventional hydraulic motor and rotary alternator. Efficiency of the low-maintenance converter design was calculated at 93.5% for a counterbalanced version and 97.0% without the counterbalance feature. If the converter were coupled to a Stirling engine with design parameters more typcial of high-technology Stirling engines, counterbalanced converter efficiency could be increased to 99.6%. Dynamic computer simulation studies were conducted to evaluate performance and system sensitivities. Production costs of the complete Stirling hydraulic/electric power system were evaluated at $6506 which compared with $8746 for an alternative Stirling engine/linear alternator system.

  13. Reduction in Design Stability Number of Monolayer Armour Units for Singular Conditions of Projects in Rubble Mound Breakwaters

    Directory of Open Access Journals (Sweden)

    Hugo Juan Donini

    2015-07-01

    Full Text Available The evaluation of concrete single layer of breakwaters is based on the application of design coefficients obtained in laboratory tests, primarily two-dimensional and under controlled conditions. With the experience of more than 30 years in structures of this type in the world, it is important to compare the values of stability numbers used in the design with those who are in breakwaters as built. In this paper, update and increase the data collected with respect to previous publications, developing an analysis of particular situations in which the amour layer stability coefficients are reduced. A series of Accropode® and Core-LocTM recommendations concerning the design elements is also made. Also there are conclusions related to increases in the volume and the reduction in the number of blocks needed for different numbers of stability proposed.

  14. Unit with Fluidized Bed for Gas-Vapor Activation of Different Carbonaceous Materials for Various Purposes: Design, Computation, Implementation.

    Science.gov (United States)

    Strativnov, Eugene

    2017-12-01

    We propose the technology of obtaining the promising material with wide specter of application-activated nanostructured carbon. In terms of technical indicators, it will stand next to the materials produced by complex regulations with the use of costly chemical operations. It can be used for the following needs: as a sorbent for hemosorption and enterosorption, for creation of the newest source of electric current (lithium and zinc air batteries, supercapacitors), and for processes of short-cycle adsorption gas separation.In this study, the author gives recommendations concerning the design of the apparatus with fluidized bed and examples of calculation of specific devices. The whole given information can be used as guidelines for the design of energy effective aggregates. Calculation and design of the reactor were carried out using modern software complexes (ANSYS and SolidWorks).

  15. Unit operation optimization for the manufacturing of botanical injections using a design space approach: a case study of water precipitation.

    Directory of Open Access Journals (Sweden)

    Xingchu Gong

    Full Text Available Quality by design (QbD concept is a paradigm for the improvement of botanical injection quality control. In this work, water precipitation process for the manufacturing of Xueshuantong injection, a botanical injection made from Notoginseng Radix et Rhizoma, was optimized using a design space approach as a sample. Saponin recovery and total saponin purity (TSP in supernatant were identified as the critical quality attributes (CQAs of water precipitation using a risk assessment for all the processes of Xueshuantong injection. An Ishikawa diagram and experiments of fractional factorial design were applied to determine critical process parameters (CPPs. Dry matter content of concentrated extract (DMCC, amount of water added (AWA, and stirring speed (SS were identified as CPPs. Box-Behnken designed experiments were carried out to develop models between CPPs and process CQAs. Determination coefficients were higher than 0.86 for all the models. High TSP in supernatant can be obtained when DMCC is low and SS is high. Saponin recoveries decreased as DMCC increased. Incomplete collection of supernatant was the main reason for the loss of saponins. Design space was calculated using a Monte-Carlo simulation method with acceptable probability of 0.90. Recommended normal operation region are located in DMCC of 0.38-0.41 g/g, AWA of 3.7-4.9 g/g, and SS of 280-350 rpm, with a probability more than 0.919 to attain CQA criteria. Verification experiment results showed that operating DMCC, SS, and AWA within design space can attain CQA criteria with high probability.

  16. Unit operation optimization for the manufacturing of botanical injections using a design space approach: a case study of water precipitation.

    Science.gov (United States)

    Gong, Xingchu; Chen, Huali; Chen, Teng; Qu, Haibin

    2014-01-01

    Quality by design (QbD) concept is a paradigm for the improvement of botanical injection quality control. In this work, water precipitation process for the manufacturing of Xueshuantong injection, a botanical injection made from Notoginseng Radix et Rhizoma, was optimized using a design space approach as a sample. Saponin recovery and total saponin purity (TSP) in supernatant were identified as the critical quality attributes (CQAs) of water precipitation using a risk assessment for all the processes of Xueshuantong injection. An Ishikawa diagram and experiments of fractional factorial design were applied to determine critical process parameters (CPPs). Dry matter content of concentrated extract (DMCC), amount of water added (AWA), and stirring speed (SS) were identified as CPPs. Box-Behnken designed experiments were carried out to develop models between CPPs and process CQAs. Determination coefficients were higher than 0.86 for all the models. High TSP in supernatant can be obtained when DMCC is low and SS is high. Saponin recoveries decreased as DMCC increased. Incomplete collection of supernatant was the main reason for the loss of saponins. Design space was calculated using a Monte-Carlo simulation method with acceptable probability of 0.90. Recommended normal operation region are located in DMCC of 0.38-0.41 g/g, AWA of 3.7-4.9 g/g, and SS of 280-350 rpm, with a probability more than 0.919 to attain CQA criteria. Verification experiment results showed that operating DMCC, SS, and AWA within design space can attain CQA criteria with high probability.

  17. Clay and Anxiety Reduction: A One-Group, Pretest/Posttest Design with Patients on a Psychiatric Unit

    Science.gov (United States)

    Kimport, Elizabeth R.; Hartzell, Elizabeth

    2015-01-01

    Little research exists on using clay as an anxiety-reducing intervention with patients in psychiatric hospitals. This article reports on a study that used a one-group, pretest/posttest design with 49 adults in a psychiatric facility who created a clay pinch pot. The State-Trait Anxiety Inventory (STAI) was used as a pre- and posttest measure.…

  18. A socio-technical approach for the design of a production control system : towards controllable production units

    NARCIS (Netherlands)

    Slomp, Jannes; Ruël, Gwenny C.

    2000-01-01

    In the design of a production control system much attention is usually paid to technicalaspects, whereas the elaboration upon social aspects remain underexposed. SociotechnicalSystems Theory (SST) emphasizes the importance of finding a joint optimization between the technical and the social systems

  19. Clay and Anxiety Reduction: A One-Group, Pretest/Posttest Design with Patients on a Psychiatric Unit

    Science.gov (United States)

    Kimport, Elizabeth R.; Hartzell, Elizabeth

    2015-01-01

    Little research exists on using clay as an anxiety-reducing intervention with patients in psychiatric hospitals. This article reports on a study that used a one-group, pretest/posttest design with 49 adults in a psychiatric facility who created a clay pinch pot. The State-Trait Anxiety Inventory (STAI) was used as a pre- and posttest measure.…

  20. Materials considerations in the design of a metal-hydride heat pump for an advanced extravehicular mobility unit

    Science.gov (United States)

    Liebert, B. E.

    1986-01-01

    A metal-hydride heat pump (HHP) has been proposed to provide an advanced regenerable nonventing thermal sink for the liquid-cooled garment worn during an extravehicular activity (EVA). The conceptual design indicates that there is a potential for significant advantages over the one presently being used by shuttle crew personnel as well as those that have been proposed for future use with the space station. Compared to other heat pump designs, a HHP offers the potential for extended use with no electrical power requirements during the EVA. In addition, a reliable, compact design is possible due to the absence of moving parts other than high-reliability check valves. Because there are many subtleties in the properties of metal hydrides for heat pump applications, it is essential that a prototype hydride heat pump be constructed with the selected materials before a committment is made for the final design. Particular care must be given to the evaporator heat exchanger worn by the astronaut since the performance of hydride heat pumps is generally heat transfer limited.

  1. Engineering design approach based on HAZOP analysis method for hydrogenation unit%基于HAZOP分析的加氢装置工程设计方法

    Institute of Scientific and Technical Information of China (English)

    宋智博; 王峰; 王成硕

    2012-01-01

    加氢装置属甲类火灾、爆炸危险生产装置.为了在设计阶段尽可能消除或控制潜在风险,本文总结了多套加氢装置HAZOP分析报告中的设备类别及其分析内容,提出了基于危险与可操作性(HAZOP)分析的加氢装置工程设计方法.在传统工程设计方法的基础上增加了参数敏感性工程设计方法,依据分析报告中的设计建议,利用ASPEN软件计算过程参数变化对,标参数的影响程度,确定参数稳定操作区域;建立了数据库管理界面实现了加氢装置工程安全设计经验知识的有序管理.应用基于HAZOP分析的加氢装置工程设计方法,有助于将安全隐患问题在设计阶段消除或加以控制,可为降低石化装置改造成本和提高装置的安全水平提供方法依据.%Hydrogenation unit is ranked as the first dangerous production equipment in fire and explosion grade. In order to eliminate or control risk in the design period, this paper summarizes equipment types and analysis content from the HAZOP analysis reports of different hydrogenation units, and presents an engineering design approach based on the HAZOP analysis method for a hydrogenation unit. HAZOP analysis has been widely used in chemical process industries. In an analysis process, P&ID should be examined by a multi-disciplinary team of experts systematically , and all conceivable deviations far from design intentions in the plant can be identified and all the possible abnormal causes and the adverse consequences of those deviations can be determined. Compared with the traditional engineering design method, parameter sensitivity engineering design method has been added. The influence extent of some parameter variations to the object parameters should be computed by the ASPEN program to determine the steady operation region according to the design suggestions offered in the analysis reports, and a database could be established to regularly manage experience knowledge for

  2. The Integration of On-Line Monitoring and Reconfiguration Functions using EDAA - European design and Automation Association1149.4 Into a Safety Critical Automotive Electronic Control Unit

    CERN Document Server

    Jeffrey, C; Prosser, S; Lickess, M; Richardson, A; Riches, S

    2011-01-01

    This paper presents an innovative application of EDAA - European design and Automation Association 1149.4 and the Integrated Diagnostic Reconfiguration (IDR) as tools for the implementation of an embedded test solution for an Automotive Electronic Control Unit implemented as a fully integrated mixed signal system. The paper described how the test architecture can be used for fault avoidance with results from a hardware prototype presented. The paper concludes that fault avoidance can be integrated into mixed signal electronic systems to handle key failure modes.

  3. Methodological Applications of Several Linguistics Disciplines to the Design of Didactic Unit on the Topic British Teenagers and bodily Perfection Obsession

    OpenAIRE

    2009-01-01

    [EN]This paper deals with various methodological applications from various disciplines and design Language Teaching Unit on the subject of British teenagers and their obsession with bodily perfection. [ES]Este trabajo trata sobre distintas aplicaciones metodológicas de diversas disciplinas Lingüísticas y el diseño de Unidades didácticas sobre el tema de los adolescentes británicos y su obsesión por la perfección corporal Trabajo de Fin de Máster del Máster en Estudios Ingleses Avanzados...

  4. Design

    DEFF Research Database (Denmark)

    Jensen, Ole B.; Pettiway, Keon

    2017-01-01

    by designers, planners, etc. (staging from above) and mobile subjects (staging from below). A research agenda for studying situated practices of mobility and mobilities design is outlined in three directions: foci of studies, methods and approaches, and epistemologies and frames of thinking. Jensen begins...... with a brief description of how movement is studied within social sciences after the “mobilities turn” versus the idea of physical movement in transport geography and engineering. He then explains how “mobilities design” was derived from connections between traffic and architecture. Jensen concludes......In this chapter, Ole B. Jensen takes a situational approach to mobilities to examine how ordinary life activities are structured by technology and design. Using “staging mobilities” as a theoretical approach, Jensen considers mobilities as overlapping, actions, interactions and decisions...

  5. Unit Cost Compendium Calculations

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Unit Cost Compendium (UCC) Calculations raw data set was designed to provide for greater accuracy and consistency in the use of unit costs across the USEPA...

  6. Design

    DEFF Research Database (Denmark)

    Volf, Mette

    Design - proces & metode iBog®  er enestående i sit fokus på afmystificering og operationalisering af designprocessens flygtige og komplekse karakter. Udgivelsen går bag om designerens daglige arbejde og giver et indblik i den kreative skabelsesproces, som designeren er en del af. Udover et bredt...... indblik i designerens arbejdsmetoder og designparametre giver Design - proces & metode en række eksempler fra anerkendte designvirksomheder, der gør det muligt at komme helt tæt på designerens virkelighed....

  7. Design and Construction of a Positron Emission Tomography (PET) Unit and Medical Applications with GEANT Detector Simulation Package

    Energy Technology Data Exchange (ETDEWEB)

    Karagoz, Muge [Bogazici Univ., Istanbul (Turkey)

    1998-01-01

    In order to investigate the possibility of the construction of a sample PET coincidence unit in our HEP laboratory, a setup with two face to face PMTs and two 2x8 Csi(Tl) scintillator matrices has been constructed. In this setup, 1-D projections of a pointlike 22 Na positron source at different angles have been measured. Using these projections a 2-D image has been formed. Monte Carlo studies of this setup have been implemented using the detector simulation tool in CERN program library, GEANT. Again with GEANT a sample human body is created to study the effects of proton therapy. Utilization of the simulation as a pretherapy tool is also investigated.

  8. The EU-project United4Health: User-Centred Design and Evaluation of a Collaborative Information System for a Norwegian Telehealth Service.

    Science.gov (United States)

    Smaradottir, Berglind; Gerdes, Martin; Martinez, Santiago; Fensli, Rune

    2015-01-01

    This study presents the user-centred design and evaluation process of a Collaborative Information System (CIS), developed for a new telehealth service for remote monitoring of chronic obstructive pulmonary disease patients after hospital discharge. The CIS was designed based on the information gathered in a workshop, where target end-users described the context of use, a telehealth workflow and their preferred ways of interaction with the solution. Evaluation of the iterative refinements were made through user tests, semi-structured interviews and a questionnaire. A field trial reported results on the ease of use and user satisfaction during the interaction with the fully developed system. The implemented CIS was successfully deployed within the secured Norwegian Health Network. The research was a result of cooperation between international partners within the EU FP7 project United4Health.

  9. Light-Weight Radioisotope Heater Unit final safety analysis report (LWRHU-FSAR): Volume 1: A. Introduction and executive summary: B. Reference Design Document (RDD)

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.W.

    1988-10-01

    The orbiter and probe portions of the National Aeronautics and Space Administration (NASA) Galileo spacecraft contain components which require auxiliary heat during the mission. To meet these needs, the Department of Energy's (DOE's) Office of Special Applications (OSA) has sponsored the design, fabrication, and testing of a one-watt encapsulated plutonium dioxide-fueled thermal heater named the Light-Weight Radioisotope Heater Unit (LWRHU). This report, prepared by Monsanto Research Corporation (MRC), addresses the radiological risks which might be encountered by people both at the launch area and worldwide should postulated mission failures or malfunctions occur, resulting in the release of the LWRHUs to the environment. Included are data from the design, mission descriptions, postulated accidents with their consequences, test data, and the derived source terms and personnel exposures for the various events. 11 refs., 44 figs., 11 tabs.

  10. Intoxicated children at an intensive care unit: popular medicine risks, complications and costs

    Directory of Open Access Journals (Sweden)

    Consuelo de Rovetto

    2009-09-01

    Full Text Available Introduction: The Hospital Universitario del Valle (HUV at the Pediatrics Intensive Care Unit (PICU admits intoxicated patients, erroneously medicated by «teguas» or family members with serious aggravation of basic diseases or generating severe intoxications. Absent reports of these practices in Colombia motivated the publication of this case seriesObjective: To report a series of pediatric intoxication cases secondary to oral or dermatological application of varied substances by healers («teguas» or family members, leading to admission at the PICU, and to describe complications and hospital costs of these events.Methodology: Clinical charts of patients admitted to the PICU with diagnosis of exogenous intoxication during May 2001 to September 2004, were reviewed. Of 28 registered cases during that time, only 14 clinical charts were recovered. Variables evaluated included: age, gender, proceeding, administered substance, person responsible for the administration, complications, days of mechanical ventilation, total days at the intensive care unit and average costs. Of the 14 medical records with exogenous intoxications only 5 cases were involuntary and 9 were related to the administration of substances by quacks or family members; these are the ones reported in this series.Results: We report a total of 9 intoxicated patients, 5 girls and 4 boys, with an age range from 1 to 24 months, all from Cali. Topical administered substances: alcohol 6/9, vinegar 1/9; oral: aspirin 2/9, paico 1/9, and unidentified herbs 1/9. Administered substances by teguas: 6 patients; 3 by family members. All patients had metabolic acidosis with an increased anion gap: 27 in average (range from 21 to 32. All required mechanical ventilation (2 to 32 day range. Average hospital day costs were $6’657,800 pesos (around U$3,000.oo. Three patients died and 4 presented acute renal failure, 2 convulsions, 2 nosocomial infections, 1 subglotic stenosis.Conclusions and

  11. Intoxicated children at an intensive care unit: popular medicine risks, complications and costs.

    Directory of Open Access Journals (Sweden)

    Consuelo de Rovetto

    2009-12-01

    Full Text Available Introduction: The Hospital Universitario del Valle (HUV at the Pediatrics Intensive Care Unit (PICU admits intoxicated patients, erroneously medicated by «teguas» or family members with serious aggravation of basic diseases or generating severe intoxications. Absent reports of these practices in Colombia motivated the publication of this case series Objective: To report a series of pediatric intoxication cases secondary to oral or dermatological application of varied substances by healers («teguas» or family members, leading to admission at the PICU, and to describe complications and hospital costs of these events. Methodology: Clinical charts of patients admitted to the PICU with diagnosis of exogenous intoxication during May 2001 to September 2004, were reviewed. Of 28 registered cases during that time, only 14 clinical charts were recovered. Variables evaluated included: age, gender, proceeding, administered substance, person responsible for the administration, complications, days of mechanical ventilation, total days at the intensive care unit and average costs. Of the 14 medical records with exogenous intoxications only 5 cases were involuntary and 9 were related to the administration of substances by quacks or family members; these are the ones reported in this series. Results: We report a total of 9 intoxicated patients, 5 girls and 4 boys, with an age range from 1 to 24 months, all from Cali. Topical administered substances: alcohol 6/9, vinegar 1/9; oral: aspirin 2/9, paico 1/9, and unidentified herbs 1/9. Administered substances by teguas: 6 patients; 3 by family members. All patients had metabolic acidosis with an increased anion gap: 27 in average (range from 21 to 32. All required mechanical ventilation (2 to 32 day range. Average hospital day costs were $6’657,800 pesos (around U$3,000.oo. Three patients died and 4 presented acute renal failure, 2 convulsions, 2 nosocomial infections, 1 subglotic stenosis. Conclusions and

  12. Design

    Science.gov (United States)

    Buchanan, Richard; Cross, Nigel; Durling, David; Nelson, Harold; Owen, Charles; Valtonen, Anna; Boling, Elizabeth; Gibbons, Andrew; Visscher-Voerman, Irene

    2013-01-01

    Scholars representing the field of design were asked to identify what they considered to be the most exciting and imaginative work currently being done in their field, as well as how that work might change our understanding. The scholars included Richard Buchanan, Nigel Cross, David Durling, Harold Nelson, Charles Owen, and Anna Valtonen. Scholars…

  13. Design

    Science.gov (United States)

    Buchanan, Richard; Cross, Nigel; Durling, David; Nelson, Harold; Owen, Charles; Valtonen, Anna; Boling, Elizabeth; Gibbons, Andrew; Visscher-Voerman, Irene

    2013-01-01

    Scholars representing the field of design were asked to identify what they considered to be the most exciting and imaginative work currently being done in their field, as well as how that work might change our understanding. The scholars included Richard Buchanan, Nigel Cross, David Durling, Harold Nelson, Charles Owen, and Anna Valtonen. Scholars…

  14. [The design of a family of ultrasonic diagnostic units based on up-to-date computer technologies].

    Science.gov (United States)

    Trukhanov, A I; Nagulin, N E

    1996-01-01

    Small ultrasonic devices are now being used in medical practice. However, the vast majority of them represent designingly completed systems which cannot include additional soft- and hardwares to accumulate measurements and to set up databases, to make additional postprocessing, to transmit measurements along networks and telephone lines, etc. On the other hand, in our and foreign countries, work is under way in designing the systems of archiving and treating ultrasonic images, working places for a physician engaged in radiation diagnosis. But at the same time direct joining of ultrasonic equipment with standard computer facilities is impossible in many practical cases. To design ultrasonic devices by using Multimedia IBM PC technology which may integrate various informational media, such as display, sonic information, and textual data is one of the ways of solving this problem. With this, the hardwares of ultrasonic devices are realized in the construction of standard IBM PC modules. Sonomed ultrasonic devices may be considered to be alternatives of Multimedia IBM PC-based devices.

  15. Design and experience with the WS/HS assembly movement using labview VIS, national instrument motion controllers, and compumotor electronic drive units and motors

    Energy Technology Data Exchange (ETDEWEB)

    Day, L. A. (Lisa A.); Gilpatrick, J. D. (John Douglas); Gruchalla, M. (Michael); Martinez, D. G. (Derwin G.); O' Hara, J. F. (James F.); Shurter, R. B. (Robert B.); Stettler, M. W. (Matthew W.); Valdiviez, R. (Robert); Barr, D. S. (Dean S.)

    2001-01-01

    The Low-Energy Demonstration Accelerator (LEDA), designed and built at the Los Alamos National Laboratory, is part of the Accelerator Production of Tritium (APT) program and provides a platform for measuring high-power proton beam-halo formation. The technique used for measuring the beam halo employs nine combination Wire Scanner and Halo Scraper (WS/HS) devices. This paper will focus on the experience gained in the use of National Instrument (NI) LabVIEW VIs and motion controllers, and Compumotor electronic drive units and motors. The base configuration couples a Compumotor motor driven by a Parker-Hannifin Gemini GT Drive unit. The drive unit is controlled by a NI PXI-7344 controller card, which in turn is controlled by a PC running custom built NI LabVIEW VIs. The function of the control VI's is to interpret instructions from the main control system, the Experimental Physics and Industrial Control System (EPICS), and carry out the corresponding motion commands. The main control VI has to run all nineteen WS/HS motor axes used in the accelerator. A basic discussion of the main accelerator control system, EPICs which is hosted on a VXI platform, and its interface with the PC based LabVIEW motion control software will be included.

  16. DESIGN OF OYSTER (PLEUROTUS OSTREATUS PRODUCTION UNIT TAKING INTO ACCOUNT ITS AGROTECHNIC OF GROWIGN AND QUALITY AND QUANTITY OF ITS PRODUCTION

    Directory of Open Access Journals (Sweden)

    Marcel Golian

    2015-02-01

    Full Text Available According to influence of population increasing followed by agricultural soils decreasing there is noticed a necessity of individual food commodities production intensification. There is also needed to think about some new unconventional and alternative sort of food-stuff. An edible mushroom growing is one of the relatively new agricultural branches, whereby on a large scale there are grown species which belong to saprophytic group. The aim of task was the building – technological and equipment – technological proposal of oyster (Pleurotus ostreatus, Jacq. P. Kumm production unit with taking account to its specific agro technical requirements and valid legislative. In the next part of task there were evaluated and compared qualitative and quantitative parameters of sporocarps from two variants which were collected in the first growth wave and accuracy of the proposed oyster production unit. In case of variant A there were used sacks with substrates, which have been exposed to cold shock by 6°C temperature for 4 days and in variant B were used substrates without cold shock. According to reached results the cold shock had almost neither influence on production quantity. There was found out an important fact that crop height from first growth wave wasn´t identical with well-known literature sources. The low crop is connected with high CO2 content in oyster production unit room, according to our opinion. Other equipment aimed to air humidity regulation, air temperature regulation and room lights was designed correctly.

  17. Design and experience with the WS/HS assembly movement using labview VIS, national instrument motion controllers, and compumotor electronic drive units and motors

    Energy Technology Data Exchange (ETDEWEB)

    Day, L. A. (Lisa A.); Gilpatrick, J. D. (John Douglas); Gruchalla, M. (Michael); Martinez, D. G. (Derwin G.); O' Hara, J. F. (James F.); Shurter, R. B. (Robert B.); Stettler, M. W. (Matthew W.); Valdiviez, R. (Robert); Barr, D. S. (Dean S.)

    2001-01-01

    The Low-Energy Demonstration Accelerator (LEDA), designed and built at the Los Alamos National Laboratory, is part of the Accelerator Production of Tritium (APT) program and provides a platform for measuring high-power proton beam-halo formation. The technique used for measuring the beam halo employs nine combination Wire Scanner and Halo Scraper (WS/HS) devices. This paper will focus on the experience gained in the use of National Instrument (NI) LabVIEW VIs and motion controllers, and Compumotor electronic drive units and motors. The base configuration couples a Compumotor motor driven by a Parker-Hannifin Gemini GT Drive unit. The drive unit is controlled by a NI PXI-7344 controller card, which in turn is controlled by a PC running custom built NI LabVIEW VIs. The function of the control VI's is to interpret instructions from the main control system, the Experimental Physics and Industrial Control System (EPICS), and carry out the corresponding motion commands. The main control VI has to run all nineteen WS/HS motor axes used in the accelerator. A basic discussion of the main accelerator control system, EPICs which is hosted on a VXI platform, and its interface with the PC based LabVIEW motion control software will be included.

  18. DESIGN AND EXPERIENCE WITH THE WS/HS ASSEMBLY MOVEMENT USING LABVIEW VIS, NATIONAL INSTRUMENT MOTION CONTROLLERS, AND COMPUMOTOR ELECTRONIC DRIVE UNITS AND MOTORS

    Energy Technology Data Exchange (ETDEWEB)

    D.S. BARR; L.A. DAY; ET AL

    2001-06-01

    The Low-Energy Demonstration Accelerator (LEDA), designed and built at the Los Alamos National Laboratory, is part of the Accelerator Production of Tritium (APT) program and provides a platform for measuring high-power proton beam-halo formation. The technique used for measuring the beam halo employs nine combination Wire Scanner and Halo Scraper (WS/HS) devices. This paper will focus on the experience gained in the use of National Instrument (NI) LabVIEW VIs and motion controllers, and Compumotor electronic drive units and motors. The base configuration couples a Compumotor motor driven by a Parker-Hannifin Gemini GT Drive unit. The drive unit is controlled by a NI PXI-7344 controller card, which in turn is controlled by a PC running custom built NI LabVIEW VIs. The function of the control VI's is to interpret instructions from the main control system, the Experimental Physics and Industrial Control System (EPICS), and carry out the corresponding motion commands. The main control VI has to run all nineteen WS/HS motor axes used in the accelerator. A basic discussion of the main accelerator control system, EPICs which is hosted on a VXI platform, and its interface with the PC based LabVIEW motion control software will be included.

  19. Design and development of control unit and software for the ADFOSC instrument of the 3.6 m Devasthal optical telescope

    Science.gov (United States)

    Kumar, T. S.

    2016-08-01

    In this paper, we describe the details of control unit and GUI software for positioning two filter wheels, a slit wheel and a grism wheel in the ADFOSC instrument. This is a first generation instrument being built for the 3.6 m Devasthal optical telescope. The control hardware consists of five electronic boards based on low cost 8-bit PIC microcontrollers and are distributed over I2C bus. The four wheels are controlled by four identical boards which are configured in I2C slave mode while the fifth board acts as an I2C master for sending commands to and receiving status from the slave boards. The master also communicates with the interfacing PC over TCP/IP protocol using simple ASCII commands. For moving the wheels stepper motors along with suitable amplifiers have been employed. Homing after powering ON is achieved using hall effect sensors. By implementing distributed control units having identical design modularity is achieved enabling easier maintenance and upgradation. A GUI based software for commanding the instrument is developed in Microsoft Visual C++. For operating the system during observations the user selects normal mode while the engineering mode is available for offering additional flexibility and low level control during maintenance and testing. A detailed time-stamped log of commands, status and errors are continuously generated. Both the control unit and the software have been successfully tested and integrated with the ADFOSC instrument.

  20. Data Base Design with GIS in Ecosystem Based Multiple Use Forest Management in Artvin, Turkey: A Case Study in Balcı Forest Management Planning Unit

    Directory of Open Access Journals (Sweden)

    Hacı Ahmet Yolasığmaz

    2009-03-01

    Full Text Available In Turkey, the understanding of planning focused on timber production has given its place on Multiple Use Management (MUM. Because the whole infrastructure of forestry with inventory system leading the way depends on timber production, some cases of bottle neck are expected during the transition period. Database design, probably the most important stage during the transition to MUM, together with the digital basic maps making up the basis of this infrastructure constitute the main point of this article. Firstly, the forest management philosophy of Turkey in the past was shortly touched upon in the article. Ecosystem Based Multiple Use Forest Management (EBMUFM approaches was briefly introduced. The second stage of the process of EBMUFM, database design was described by examining the classical planning infrastructure and the coverage to be produced and consumed were suggested in the form of lists. At the application stage, two different geographical databases were established with GIS in Balcı Planning Unit of the years 1984 and 2006. Following that the related basic maps are produced. Timely diversity of the planning unit of 20 years is put forward comparatively with regard to the stand parameters such as tree types, age class, development stage, canopy closure, mixture, volume and increment.

  1. Professor Sir Mark Walport Government Chief Scientific Adviser Head of Government Science and Engineering Profession Chief Executive Designate of UK Research and Innovation United Kingdom of Great Britain and Northern Ireland

    CERN Multimedia

    Bennett, Sophia Elizabeth

    2017-01-01

    Professor Sir Mark Walport Government Chief Scientific Adviser Head of Government Science and Engineering Profession Chief Executive Designate of UK Research and Innovation United Kingdom of Great Britain and Northern Ireland

  2. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). As-Designed Parts List: Electrical, Electronic, and Electromechanical (EEE) As-Built Parts List for the AMSU-A Instruments

    Science.gov (United States)

    2000-01-01

    This is the As-Designed Parts List, Electrical, Electronic, and Electromechanical (EEE) As-Built Parts Lists For The AMSU-A Instruments, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  3. Design for learning – a case study of blended learning in a science unit [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Roslyn Gleadow

    2015-09-01

    Full Text Available Making material available through learning management systems is standard practice in most universities, but this is generally seen as an adjunct to the ‘real’ teaching, that takes place in face-to-face classes. Lecture attendance is poor, and it is becoming increasingly difficult to engage students, both in the material being taught and campus life. This paper describes the redevelopment of a large course in scientific practice and communication that is compulsory for all science students studying at our Melbourne and Malaysian campuses, or by distance education. Working with an educational designer, a blended learning methodology was developed, converting the environment provided by the learning management system into a teaching space, rather than a filing system. To ensure focus, topics are clustered into themes with a ‘question of the week’, a pre-class stimulus and follow up activities. The content of the course did not change, but by restructuring the delivery using educationally relevant design techniques, the content was contextualised resulting in an integrated learning experience. Students are more engaged intellectually, and lecture attendance has improved. The approach we describe here is a simple and effective approach to bringing this university’s teaching and learning into the 21st century.

  4. Design for learning – a case study of blended learning in a science unit [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Roslyn Gleadow

    2015-11-01

    Full Text Available Making material available through learning management systems is standard practice in most universities, but this is generally seen as an adjunct to the ‘real’ teaching, that takes place in face-to-face classes. Lecture attendance is poor, and it is becoming increasingly difficult to engage students, both in the material being taught and campus life. This paper describes the redevelopment of a large course in scientific practice and communication that is compulsory for all science students studying at our Melbourne and Malaysian campuses, or by distance education. Working with an educational designer, a blended learning methodology was developed, converting the environment provided by the learning management system into a teaching space, rather than a filing system. To ensure focus, topics are clustered into themes with a ‘question of the week’, a pre-class stimulus and follow up activities. The content of the course did not change, but by restructuring the delivery using educationally relevant design techniques, the content was contextualised resulting in an integrated learning experience. Students are more engaged intellectually, and lecture attendance has improved. The approach we describe here is a simple and effective approach to bringing this university’s teaching and learning into the 21st century.

  5. Effect of N-Methyl-D-Aspartate Receptor Antagonist Dextromethorphan on Opioid Analgesia in Pediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Mohammed Naeem

    2016-01-01

    Full Text Available Objective. Pain control is an essential goal in the management of critical children. Narcotics are the mainstay for pain control. Patients frequently need escalating doses of narcotics. In such cases an adjunctive therapy may be beneficial. Dextromethorphan (DM is NMDA receptor antagonist and may prevent tolerance to narcotics; however, its definitive role is still unclear. We sought whether dextromethorphan addition could decrease the requirements of fentanyl to control pain in critical children. Design. Double-blind, randomized control trial (RCT. Setting. Pediatric multidisciplinary ICU in tertiary care center. Patients. Thirty-six pediatric patients 2–14 years of age in a multidisciplinary PICU requiring analgesia were randomized into dextromethorphan and placebo. The subjects in both groups showed similarity in most of the characteristics. Interventions. Subjects while receiving fentanyl for pain control received dextromethorphan or placebo through nasogastric/orogastric tubes for 96 hours. Pain was assessed using FLACC and faces scales. Measurements and Main Results. This study found no statistical significant difference in fentanyl requirements between subjects receiving dextromethorphan and those receiving placebo (p=0.127. Conclusions. Dextromethorphan has no effect on opioid requirement for control of acute pain in children admitted with acute critical care illness in PICU. The registration number for this trial is NCT01553435.

  6. Technology transfer with system analysis, design, decision making, and impact (Survey-2000) in acute care hospitals in the United States.

    Science.gov (United States)

    Hatcher, M

    2001-10-01

    This paper provides the results of the Survey-2000 measuring technology transfer for management information systems in health care. The relationships with systems approaches, user involvement, usersatisfaction, and decision-making were measured and are presented. The survey also measured the levels Internet and Intranet presents in acute care hospitals, which will be discussed in future articles. The depth of the survey includes e-commerce for both business to business and customers. These results are compared, where appropriate, with results from survey 1997 and changes are discussed. This information will provide benchmarks for hospitals to plan their network technology position and to set goals. This is the first of three articles based upon the results of the Srvey-2000. Readers are referred to a prior article by the author that discusses the survey design and provides a tutorial on technology transfer in acute care hospitals.

  7. Implementation of smart pump technology in a paediatric intensive care unit.

    Science.gov (United States)

    Manrique-Rodríguez, Silvia; Sánchez-Galindo, Amelia C; de Lorenzo-Pinto, Ana; González-Vives, Leticia; López-Herce, Jesús; Carrillo-Álvarez, Ángel; Sanjurjo-Sáez, María; Fernández-Llamazares, Cecilia M

    2015-09-01

    Patient safety is a matter of major concern that involves every health professional. Nowadays, emerging technologies such as smart pumps can diminish medication errors as well as standardise and improve clinical practice with the subsequent benefits for patients. The aim of this paper was to describe the smart pump implementation process in a paediatric intensive care unit (PICU) and to present the most relevant infusion-related programming errors that were prevented. This was a comparative study between CareFusion Alaris Guardrails(®) and Hospira MedNet(®) systems, as well as a prospective and intervention study with analytical components carried out in the PICU of Gregorio Marañón General and Teaching Hospital. All intravenous infusions programmed with a pump in the eleven beds of the unit were analyzed. A drug library was developed and subsequently loaded into CareFusion and Hospira pumps that were used during a three month period each. The most suitable system for implementation was selected according to their differences in features and users' acceptance. Data stored in the pumps were analyzed to assess user compliance with the technology, health care setting and type of errors intercepted. The implementation process was carried out with CareFusion systems. Compliance with the technology was 92% and user acceptance was high. Vacation substitution and drug administration periods were significantly associated with a greater number of infusion-related programming errors. High risk drugs were involved in 48% of intercepted errors. Based on these results we can conclude that implementation of smart pumps proved effective in intercepting infusion-related programming errors from reaching patients. User awareness of the importance of programming infusions with the drug library is the key to succeed in the implementation process. © The Author(s) 2013.

  8. The Challenges of Providing Effective Pain Management for Children in the Pediatric Intensive Care Unit.

    Science.gov (United States)

    Ismail, Ahmad

    2016-12-01

    Providing effective pain management is necessary for all patients in the intensive care unit (ICU). Because of developmental considerations, caring for children may provide additional challenges. The purpose of this literature review is to describe key challenges in providing effective pain management in pediatric intensive care units (PICUs), with the aim of bringing about a better understanding by health care providers caring for children. Challenges of providing effective pain management in the PICU can be categorized into four levels. These levels are informed by the Nursing Pain Management Model and include challenges (1) to be considered before pain assessment, (2) related to pain assessment, (3) related to pain treatment, and (4) related to post-treatment. This review mainly discusses the challenges of the first three levels because the fourth (post-treatment) relates to reassessment of pain, which shares the same challenges of level two, pain assessment. Key challenges of level one are related to health care provider's characteristics, patients and their families' factors, and PICU setting. The main challenges of the assessment and reassessment levels are the child's age and developmental level, ability to self-report, relying on behavioral and physiological indicators of pain, selecting the appropriate pain assessment scale, assessing pain while the patient is being treated with sedative and paralytic agents, mechanical ventilation, and changes in patients' level of consciousness. In the treatment level (level three), nonpharmacological interventions factors; alterations in the pharmacokinetics and pharmacodynamics of medications to be used for pain management in critically ill children; and the complexity of the administration of sedatives, analgesics, and paralytic agents in critically ill children are the main challenges. Health care providers can bear in mind such important challenges in order to provide effective pain management. Health care providers

  9. Structure Optimization and Design of the Belt Pumping Unit%皮带抽油机机架的结构优化设计

    Institute of Scientific and Technical Information of China (English)

    李强; 邓子龙; 许龙; 陈红娟

    2013-01-01

    通过三维ANSYS软件建立皮带抽油机机架的三维模型,运用该软件对皮带抽油机架结构进行分析,得到机架最大应力和位移的分布云图,由分析结果得到一些结论。在此基础上对抽油机机架进行结构优化,提出3种改进结构模型,对3种结构模型进行分析,得到相应的位移和应力分布云图。结果表明:即使抽油机的结构设计符合要求,也可进行进一步的结构优化,更改斜支撑结构和角钢型号,对主要受力位置进行改进,改善受力状态,结构会更趋于合理,经济适用。%Through 3d ANSYS software ,the belt pumping unit 3d model was established ,the belt pumping unit structure was analyzed .Got the support maximum stress and displacement distribution maps ,got some conclusion by analyzing the results .Based on this for the pumping unit for structure optimization design ,three kinds of improved models was put forward , though the three kinds of models analysis ,got the three models of the displacement and stress distribution maps .The results show that even the oil pumping unit design meet the requirements ,it also can proceed the further optimization ,changing the stress smaller angle stress model and raking prop ,strengthen the main force position ,not only greatly improve the stress state ,but also make the structure more reasonable ,economy applicable .

  10. Quantifying the Relationship Among Hospital Design, Satisfaction, and Psychosocial Functioning in a Pediatric Hematology-Oncology Inpatient Unit

    Science.gov (United States)

    Sherman-Bien, Sandra A.; Malcarne, Vanessa L.; Roesch, Scott; Varni, James W.; Katz, Ernest R.

    2013-01-01

    Increasingly, empirical support demonstrates that the built environment may affect the physical and psychosocial well-being of patients, their families, and hospital staff (Beauchemin & Hays, 1996; Rubin, Owens, & Golden, 1998; Sherman, Varni, Ulrich, & Malcarne, 2005; Ulrich, 1991; Varni et al., 2004; Whitehouse et al., 2001). Investigators posit two mechanisms through which the built environment can impact patients: indirectly, by enhancing the quality of care and helping a patient feel more relaxed; and/or directly, by altering the physiological recovery process (Malcolm, 1992). Several literature reviews have been published on the relationship between the hospital built environment and patient outcomes (Joseph, Keller, & Kronick, 2008; Rubin et al., 1998; Sherman, Shepley, & Varni, 2005; Ulrich, Quan, Zimring, Joseph, & Choudhary, 2004). In their 1998 review, Rubin et al. found studies linking environment with a number of health and satisfaction outcomes but little research that had been conducted in a scientifically valid manner. Ulrich et al.'s 2004 review of the role of the physical environment in hospital design identified a number of more rigorously conducted studies, focusing mainly on adult environments and on issues of medical safety and hospital-acquired infection rates. Their conclusions linked environmental features such as noise to an increase in perceived stress and physiological arousal; exposure to natural light to reductions in depression, length of hospital stay, and pain medications and to improved sleep; and hospital gardens to improved physical and psychosocial functioning (Ulrich et al., 2004). PMID:21960191

  11. Remedial Design/Remedial Action Work Plan for Operable Units 6-05 and 10-04, Phase IV

    Energy Technology Data Exchange (ETDEWEB)

    R. P. Wells

    2006-11-14

    This Phase IV Remedial Design/Remedial Action Work Plan addresses the remediation of areas with the potential for UXO at the Idaho National Laboratory. These areas include portions of the Naval Proving Ground, the Arco High-Altitude Bombing Range, and the Twin Buttes Bombing Range. Five areas within the Naval Proving Ground that are known to contain UXO include the Naval Ordnance Disposal Area, the Mass Detonation Area, the Experimental Field Station, The Rail Car Explosion Area, and the Land Mine Fuze Burn Area. The Phase IV remedial action will be concentrated in these five areas. For other areas, such as the Arco High-Altitude Bombing Range and the Twin Buttes Bombing Range, ordnance has largely consisted of sand-filled practice bombs that do not pose an explosion risk. Ordnance encountered in these areas will be addressed under the Phase I Operations and Maintenance Plan that allows for the recovery and disposal of ordnance that poses an imminent risk to human health or the environment.

  12. Design, construction, operation, and evaluation of a prototype culm combustion boiler/heater unit. Quarterly technical progress report, October 1-December 21, 1981

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    This report provides a summary of the work performed on the Prototype Culm Combustion Boiler/Heater Unit, Phase I - Engineering Design and Analysis, Phase II - Prototype Plant Construction and Phase III - Start-Up and Operation during the period October 1, 1981 through December 31, 1981. The objectives of the program as well as the technical progress and problem areas encountered during the reporting period are presented. Seven shakedown tests were run. Start-up and shakedown testing was completed. Four parametric tests were run. Performance data are presented with the exception of boiler efficiency which will be reported once chemical analyses are completed. Total boiler operation time through the end of this quarter - 1225 h, 50 min; operating time on culm and culm/limestone - 682 h, 43 min. Inspection revealed no problems with boiler tube wear. Sulfur capture greater than 94% was demonstrated (design is 88%). A turndown of better than 4 to 1 was shown (design is 2.5 to 1). Computer control of most of the loops has been successful and manual control was also demonstrated.

  13. Measurement and correlation of supercritical CO2 and ionic liquid systems for design of advanced unit operations

    Institute of Scientific and Technical Information of China (English)

    Hiroshi MACHIDA; Ryosuke TAGUCHI; Yoshiyuki SATO; Louw J.FLORUSSE; Cor J.PETERS; Richard L.SMITH,Jr

    2009-01-01

    Ionic liquids combined with supercritical fluid technology hold great promise as working solvents for developing compact processes. Ionic liquids, which are organic molten salts, typically have extremely low volatility and high functionality, but possess high viscos-ities, surface tensions and low diffusion coefficients, which can limit their applicability. CO2, on the other hand,especially in its supercritical state, is a green solvent that can be used advantageously when combined with the ionic liquid to provide viscosity and surface tension reduction and to promote mass transfer. The solubility of CO2 in the ionic liquid is key to estimating the important physical properties that include partition coefficients, viscosities,densities, interfacial tensions, thermal conductivities and heat capacities needed in contactor design. In this work, we examine a subset of available high pressure pure component ionic liquid PVT data and high pressure CO2-ionic liquid solubility data and report new correlations for CO2-ionic liquid systems with equations of state that have some industrial applications including: (1) general, (2) fuel desulfurization, (3) CO2 capture, and (4) chiral separation.New measurements of solubility data for the CO2 and 1-butyl-3-methylimidazolium octyl sulfate, [bmim][OcSO4] system are reported and correlated. In the correlation of the CO2 ionic liquid phase behavior, the Peng-Robinson and the Sanchez-Lacombe equations of state were considered and are compared. It is shown that excellent correlation of CO2 solubility can be obtained with either equation and they share some common characteristics regarding inter-action parameters. In the Sanchez-Lacombe equation,parameters that are derived from the supercritical region were found to be important for obtaining good correlation of the CO2-ionic liquid solubility data.

  14. Needs of Parents in Caring for Their Children in a Pediatric Intensive Care Unit.

    Science.gov (United States)

    Valderrama Sanabria, Mery Luz; Muñoz de Rodríguez, Lucy

    2016-04-01

    This work sought to describe the needs of parents to participate in caring for their children hospitalized in a pediatric intensive care unit (PICU). This is a qualitative study based on the ethno-nursing research method proposed by Leininger. For data collection and analysis, in-depth open interviews were used, along with field notes and enabler guidelines proposed by Leininger: stranger-friend, observation, participation, reflexion, and the Sunrise model. Parents of children hospitalized in a PICU in the city of Tunja (Boyacá, Colombia) participated between February 2012 and October 2013. The needs of parents to care for their children were described in the following themes: clear and timely communication, familiarization with technology, the value of the family, favoring the parent-children interaction during visits, and valuing and respecting generic (folk) knowledge. The study provides knowledge, from the cultural perspective of parents with children hospitalized in PICU, as input to plan and develop care actions with them, according to their own needs.Objetivo.Describir las necesidades de padres para participar del cuidado de sus hijos hospitalizados en la Unidad de Cuidado Intensivo Pediátrico (UCIP). Métodos. Investigación cualitativa basada en el método de la etnoenfermería propuesto por Leininger. Para la recolección y análisis de la información se utilizaron la entrevista abierta a profundidad, las notas de campo y guías facilitadoras propuestas por Leininger: Extraño amigo, Observación, Participación Reflexión y el modelo del sol naciente. Participaron los padres de niños hospitalizados en una UCIP de Tunja (Boyacá, Colombia) entre febrero de 2012 y Octubre de 2013. Resultados. Se describen las necesidades de los padres para cuidar a sus hijos en los siguientes temas: Comunicación clara y oportuna, Familiarización con la Tecnología, El valor de la familia, Favorecer la interacción de padres-hijos durante la visita y Valorar y

  15. Design and construction of coal/biomass to liquids (CBTL) process development unit (PDU) at the University of Kentucky Center for Applied Energy Research (CAER)

    Energy Technology Data Exchange (ETDEWEB)

    Placido, Andrew [Univ. of Kentucky, Lexington, KY (United States); Liu, Kunlei [Univ. of Kentucky, Lexington, KY (United States); Challman, Don [Univ. of Kentucky, Lexington, KY (United States); Andrews, Rodney [Univ. of Kentucky, Lexington, KY (United States); Jacques, David [Univ. of Kentucky, Lexington, KY (United States)

    2015-10-30

    This report describes a first phase of a project to design, construct and commission an integrated coal/biomass-to-liquids facility at a capacity of 1 bbl. /day at the University of Kentucky Center for Applied Energy Research (UK-CAER) – specifically for construction of the building and upstream process units for feed handling, gasification, and gas cleaning, conditioning and compression. The deliverables from the operation of this pilot plant [when fully equipped with the downstream process units] will be firstly the liquid FT products and finished fuels which are of interest to UK-CAER’s academic, government and industrial research partners. The facility will produce research quantities of FT liquids and finished fuels for subsequent Fuel Quality Testing, Performance and Acceptability. Moreover, the facility is expected to be employed for a range of research and investigations related to: Feed Preparation, Characteristics and Quality; Coal and Biomass Gasification; Gas Clean-up/ Conditioning; Gas Conversion by FT Synthesis; Product Work-up and Refining; Systems Analysis and Integration; and Scale-up and Demonstration. Environmental Considerations - particularly how to manage and reduce carbon dioxide emissions from CBTL facilities and from use of the fuels - will be a primary research objectives. Such a facility has required significant lead time for environmental review, architectural/building construction, and EPC services. UK, with DOE support, has advanced the facility in several important ways. These include: a formal EA/FONSI, and permits and approvals; construction of a building; selection of a range of technologies and vendors; and completion of the upstream process units. The results of this project are the FEED and detailed engineering studies, the alternate configurations and the as-built plant - its equipment and capabilities for future research and demonstration and its adaptability for re-purposing to meet other needs. These are described in

  16. 整体化有序设计单元教学探讨%Discussion on Systemic and Systematic Design of Unit Instruction

    Institute of Scientific and Technical Information of China (English)

    马兰

    2012-01-01

    整体化有序设计单元教学致力于以单元为模块,在设计教学时既做到目标为本、统揽全局,又实现有序操作、步步落实。它旨在改变“说做相悖”的经验式备课方式、“重细节轻整体”的教学思维、“做中学”与“用心想”双峰对峙的教师培养和学习模式,其五个操作步骤为:钻研课程标准,分析教材;整合单元内容,编制目标;分析学习起点,洞察学情;预设评估要求,拟订量规;选择教学策略,形成方案。%Systemic and systematic design of unit instruction uses unit as module , which not only iocuses on teaching objectives, governing the overall situation but also realize the oderly operation and gradual implementation when desiging teaching. It aims at changing the way of experience-based lesson preparation which results in the contrary between theory and practice, altering the formula thinking of instruction which regards details and ignores entirety, and improving the confrontation between "hands on" and "minds on" in the mode of teacher cultivation and learning. Its five operation steps are investigating curriculum standards and analyzing text; integrating instructional content of unit and writing instructional objectives; analyzing learning entry levels and see clearly the students' conditions;presetting evaluation requirements and studying out instructional rubrics; selecting instructional strategies and completing instructional program.

  17. 泰山联合大学建筑方案设计探析%ANALYSIS IN ARCHITECTURAL DESIGN OF MOUNTAIN TAI UNITED UNIVERSITIES

    Institute of Scientific and Technical Information of China (English)

    李竞群

    2001-01-01

    通过泰山联合大学方案设计实例,探讨了文化性建筑中所涉及到的系列问题,其中重点探讨了文化性建筑中校园建筑形象的标志性和象征意义,以及建筑的人文环境与自然环境的关系等问题。%This article expounds a series of factors about cultural building by architectural designs of Mountain Tai United Universities. Especially,the article focuses on two aspects,the first is the architectural emblem and symbol quality of school building,the second is the relationship of human environment and nature environment.

  18. A Design for VLIW Microprocessor Based on Minium Operation Unit%基于最小操作单元的VLIW微处理器设计

    Institute of Scientific and Technical Information of China (English)

    王昭顺; 王许书; 王俊宇

    2001-01-01

    in this paper, we presented a new method called granularity analysis method which can analyze developing history of microprocessor architecture, and predicted developing trend of microprocessor architecture with this method. After we presented a new architecture called Minium Operating Unit-Based (MOUB), we also designed and implement a microprocessor model of MOUB.%提出一种微处理器体系结构发展的分析方法一粒度分析方法,并用这种方法分析了微处理器体系结构的发展趋势.在此基础上提出基于最小操作单元MOUUB微处理器体系结构的设计思想,并设计实现了一个这种结构的微处理器模型.

  19. Analysis and Design of a Permanent Magnet Bi-Stable Electro-Magnetic Clutch Unit for In-Wheel Electric Vehicle Drives

    Directory of Open Access Journals (Sweden)

    Wanli Cai

    2015-06-01

    Full Text Available Clutches have been used in internal combustion vehicles and concentrated electric vehicles (EVs to smoothen impulsion while starting and shifting. This paper proposes a permanent magnet bi-stable electromagnetic clutch unit (PMBECU which is specially introduced into in-wheel EVs to make the rigid connection between hub and wheel more flexible. Firstly, the operation principle of the PMBECU is illustrated. Then, the basic magnetic circuit model is presented and analyzed, followed by optimal design of the main structural parameters by investigating the PM leakage flux coefficient. Further, according to the basic electromagnetic characteristics of the PMBECU, the current pulse supply is put forward, and the minimum pulse width which enables the operation of the PMBECU and its dynamic characteristics are analyzed by an improved finite element method. Finally, a prototype machine is manufactured and tested to validate all the analysis results.

  20. Removal of Cu(II) ions by biosorption onto powdered waste sludge (PWS) prior to biological treatment in an activated sludge unit: a statistical design approach.

    Science.gov (United States)

    Pamukoglu, M Yunus; Kargi, Fikret

    2009-04-01

    Biological treatment of synthetic wastewater containing Cu(II) ions was realized in an activated sludge unit with pre-adsorption of Cu(II) onto powdered waste sludge (PWS). Box-Behnken experimental design method was used to investigate Cu(II), chemical oxygen demand (COD) and toxicity removal performance of the activated sludge unit under different operating conditions. The independent variables were the solids retention time (SRT, 5-30 d), hydraulic residence time (HRT, 5-25 h), feed Cu(II) concentration (0-50 mg L(-1)) and PWS loading rate (0-4 g h(-1)) while percent Cu(II), COD, toxicity (TOX) removals and the sludge volume index (SVI) were the objective functions. The data were correlated with a quadratic response function (R2=0.99). Cu(II), COD and toxicity removals increased with increasing PWS loading rate and SRT while decreasing with the increasing feed Cu(II) concentration and HRT. Optimum conditions resulting in maximum Cu(II), COD, toxicity removals and SVI values were found to be SRT of 30 d, HRT 15 h, PWS loading rate 3 g h(-1) and feed Cu(II) concentration of less than 30 mg L(-1).