WorldWideScience

Sample records for unit general electric

  1. TRAC development at General Electric

    International Nuclear Information System (INIS)

    Andersen, J.G.M.; Shaug, J.C.; Shiralkar, B.S.

    1987-01-01

    TRAC is a computer code for transient analysis of light water reactors. The BWR version of TRAC has been developed as a result of a close cooperation between General Electric Company and Idaho National Engineering Laboratory. Up through 1985 the development work at General Electric was jointly funded by General Electric, the Nuclear Regulatory Commission and Electric Power Research Institute under the Refill-Reflood and FIST programs. At INEL (which has the main responsibility for the NRC version of TRAC-BWR) this work has led to the development of TRACBD1 and TRACBF1, while at GE, TRACB04 was the final product of the Refill-Reflood and FIST programs. TRAC development has continued at General Electric after the completion of these programs with the evolution of the TRACG code. The purpose of the paper is to describe this work. The TRAC development at General Electric can be divided into two main categories: extended benchmark capability and improved user convenience

  2. 76 FR 55111 - United States v. General Electric Co., et al.; Proposed Final Judgment and Competitive Impact...

    Science.gov (United States)

    2011-09-06

    ... automation controls. Converteam manufactures and assembles medium-voltage large electric motors in facilities... conversion engineering company focusing on motors, generators, drives, converters and automation controls... Electric Machinery Business used in the design, development, production, marketing, servicing, distribution...

  3. United Kingdom electric system privatization

    Energy Technology Data Exchange (ETDEWEB)

    Lolli, A. (Bologna Univ. (Italy))

    1992-03-01

    This paper reviews the mechanics and first results of deregulation in the electric power industry of the United Kingdom. Several aspects are dealt with, namely: 1983 Energy Act impacts on ownership and subsequent changes brought about by the 1989 Energy Act; the Act's stipulations with regard to share acquisition and distribution; the division of the patrimony of the Area Boards; natural monopolistic characteristics of power distribution; vertical integration in Scotland, target investment limits in Government and public participation; the 'golden share' concept to guarantee public participation; current 40% share ownership by the Government; 15% private ownership limit for individual investors; external control by Government of licensing and rate structure setting; the impacts of organizational changes on the overall cost benefits of deregulation; modified Governmental regulatory powers; measures to ensure competition and consumer protection; provisions regarding misbehaviour; second tier suppliers and reserve fuel supply obligations; deregulation impacts on nuclear power marketing; power pooling regulations; installation of new transmission lines; provisions encouraging the use of diverse energy sources; franchising; interconnection with national grid; regulation of technical operations; standby as it affects rate structure; and spot market pricing.

  4. Electric trade in the United States 1990

    International Nuclear Information System (INIS)

    1992-01-01

    Electric Trade in the United States 1990 (ELECTRA) is the third in a series of reports on wholesale power transactions prepared by the Electric Data Systems Branch, Survey Management Division, Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA). The electric trade data are published biennially. The first report presented 1986 data. The second report contained data for 1988. This report provides information on the industry during 1990

  5. Electric trade in the United States 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-08-01

    Wholesale trade in electricity plays an important role for the US electric utility industry. Wholesale, or bulk power, transactions allow electric utilities to reduce power costs, increase power supply options, and improve reliability. In 1994, the wholesale trade market totaled 1.9 trillion kilowatthours, about 66% of total sales to ultimate consumers. This publication, Electric Trade in the United States 1994 (ELECTRA), is the fifth in a series of reports on wholesale power transactions prepared by the Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA). The electric trade data are published biennially. The first report presented 1986 data, and this report provides information on the electric power industry during 1994.

  6. Electric trade in the United States 1994

    International Nuclear Information System (INIS)

    1998-08-01

    Wholesale trade in electricity plays an important role for the US electric utility industry. Wholesale, or bulk power, transactions allow electric utilities to reduce power costs, increase power supply options, and improve reliability. In 1994, the wholesale trade market totaled 1.9 trillion kilowatthours, about 66% of total sales to ultimate consumers. This publication, Electric Trade in the United States 1994 (ELECTRA), is the fifth in a series of reports on wholesale power transactions prepared by the Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA). The electric trade data are published biennially. The first report presented 1986 data, and this report provides information on the electric power industry during 1994

  7. A General Overview of Electric Road Vehicles

    International Nuclear Information System (INIS)

    Lamblin, Veronique

    2018-01-01

    In July 2017 Nicolas Hulot, the French Minister of Ecological and Inclusive Transition, presented a climate plan featuring an end to electricity generation from coal by 2022, a reduction in the nuclear component of electricity supply by one third, a total ban on the sale of petrol or diesel cars by 2040 and an incentive scheme designed gradually to remove polluting vehicles from the roads. Other European partners are following suit and promoting the spread of electric vehicles (Norway, Germany, Netherlands etc.). Yet is this the panacea that will meet the targets for greenhouse gas reduction in the battle against climate change? Futuribles examines the question in this issue with two articles: the first of these by Pierre Bonnaure, above, assesses the forces driving the spread of electric cars and the impediments to that process; this second article by Veronique Lamblin offers a general over - view of electric road vehicles (passenger cars, heavy good vehicles, bicycles etc.) throughout the world. (author)

  8. Electric trade in the United States, 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    Wholesale trade in electricity plays an important role for the US electric utility industry. Wholesale, or bulk power, transactions allow electric utilities to reduce power costs, increase power supply options, and improve reliability. In 1996, the wholesale trade market totaled 2.3 trillion kilowatthours, over 73% of total sales to ultimate consumers. This publication, Electric Trade in the United States 1996 (ELECTRA), is the sixth in a series of reports on wholesale power transactions prepared by the Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA). The electric trade data are published biennially. The first report presented 1986 data, and this report provides information on the electric power industry during 1996. The electric trade data collected and presented in this report furnish important information on the wholesale structure found within the US electric power industry. The patterns of interutility trade in the report support analyses of wholesale power transactions and provide input for a broader understanding of bulk power market issues that define the emerging national electric energy policies. The report includes information on the quantity of power purchased, sold, exchanged, and wheeled; the geographical locations of transactions and ownership classes involved; and the revenues and costs. 1 fig., 43 tabs.

  9. Indoor unit for electric heat pump

    Science.gov (United States)

    Draper, R.; Lackey, R.S.; Fagan, T.J. Jr.; Veyo, S.E.; Humphrey, J.R.

    1984-05-22

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module, an air mover module, and a resistance heat package module, the refrigeration module including all of the indoor refrigerant circuit components including the compressor in a space adjacent the heat exchanger, the modules being adapted to be connected to air flow communication in several different ways as shown to accommodate placement of the unit in various orientations. 9 figs.

  10. Artificial Intelligence Research at General Electric

    OpenAIRE

    Sweet, Larry

    1985-01-01

    General Electric is engaged in a broad range of research and development activities in artificial intelligence, with the dual objectives of improving the productivity of its internal operations and of enhancing future products and services in its aerospace, industrial, aircraft engine, commercial, and service sectors. Many of the applications projected for AI within GE will require significant advances in the state of the art in advanced inference, formal logic, and architectures for real-tim...

  11. Insuring unit failures in electricity markets

    International Nuclear Information System (INIS)

    Pineda, S.; Conejo, A.J.; Carrion, M.

    2010-01-01

    An electric energy producer participates in futures markets in the hope of hedging the risk of trading in the pool. However, this producer is required to supply the energy associated with all its signed forward contracts even if some of its units are forced out due to unexpected failures. In this case, the producer must purchase some of the energy needed to meet its futures market commitments in the pool, which may result in high losses if the pool prices happen to be higher than the forward contract prices. To mitigate these losses, the producer can take out insurance against the forced outages of its units. Using a stochastic programming model, this paper analyzes the convenience of signing an insurance against unit failure by an electric energy producer and its impact on forward contracting decisions. Results from a realistic case study are provided and analyzed.

  12. General Electric's training program for BWR chemists

    International Nuclear Information System (INIS)

    Osborn, R.N.; Lim, W.

    1981-01-01

    This paper describes the development and implementation of the General Electric boiling water reactor chemistry training program from 1959 to the present. The original intention of this program was to provide practical hands on type training in radiochemistry to BWR chemistry supervisors with fossil station experience. This emphasis on radiochemistry has not changed through the years, but the training has expanded to include the high purity water chemistry of the BWR and has been modified to include new commission requirements, engineering developments and advanced instrumentation. Student and instructor qualifications are discussed and a description of the spin off courses for chemistry technicians and refresher training is presented

  13. Radwaste volume reduction and solidification by General Electric

    International Nuclear Information System (INIS)

    Green, T.A.; Weech, M.E.; Miller, G.P.; Eberle, J.W.

    1982-01-01

    Since 1978 General Electric has been actively engaged in developing a volume reduction and solidifcation system or treatment of radwaste generated in commercial nuclear power plants. The studies have been aimed at defining an integrated system that would be directly responsive to the rapid evolving needs of the industry for the volume reduction and solidification of low-level radwaste. The resulting General Electric Volume Reduction System (GEVRS) is an integrated system based on two processes: the first uses azeotropic distillation technology and is called AZTECH, and the second is controlled-air incineration...called INCA. The AZTECH process serves to remove water from concentrated salt solutions, ion exchange resins and filter sludge slurries and then encapsulates the dried solids into a dense plastic product. The INCA unit serves to reduce combustible wastes to ashes suitable for encapsulation into the same plastic product produced by AZTECH

  14. 78 FR 56594 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-09-13

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA... General Electric Company (GE) GE90-76B, -85B, -90B, -94B, -110B1, and - 115B turbofan engines. This AD was...) Applicability This AD applies to General Electric Company (GE): (1) GE90-76B, -85B, -90B, and -94B turbofan...

  15. 78 FR 72552 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-12-03

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA... General Electric Company model GEnx-2B67 and GEnx-2B67B turbofan engines. This AD was prompted by the... certain serial number General Electric Company (GE) model GEnx-2B67 and GEnx-2B67B turbofan engines. The...

  16. Taxation of United States general aviation

    Science.gov (United States)

    Sobieralski, Joseph Bernard

    General aviation in the United States has been an important part of the economy and American life. General aviation is defined as all flying excluding military and scheduled airline operations, and is utilized in many areas of our society. The majority of aircraft operations and airports in the United States are categorized as general aviation, and general aviation contributes more than one percent to the United States gross domestic product each year. Despite the many benefits of general aviation, the lead emissions from aviation gasoline consumption are of great concern. General aviation emits over half the lead emissions in the United States or over 630 tons in 2005. The other significant negative externality attributed to general aviation usage is aircraft accidents. General aviation accidents have caused over 8000 fatalities over the period 1994-2006. A recent Federal Aviation Administration proposed increase in the aviation gasoline tax from 19.4 to 70.1 cents per gallon has renewed interest in better understanding the implications of such a tax increase as well as the possible optimal rate of taxation. Few studies have examined aviation fuel elasticities and all have failed to study general aviation fuel elasticities. Chapter one fills that gap and examines the elasticity of aviation gasoline consumption in United States general aviation. Utilizing aggregate time series and dynamic panel data, the price and income elasticities of demand are estimated. The price elasticity of demand for aviation gasoline is estimated to range from -0.093 to -0.185 in the short-run and from -0.132 to -0.303 in the long-run. These results prove to be similar in magnitude to automobile gasoline elasticities and therefore tax policies could more closely mirror those of automobile tax policies. The second chapter examines the costs associated with general aviation accidents. Given the large number of general aviation operations as well as the large number of fatalities and

  17. An Introduction to Retail Electricity Choice in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Shengru [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-04

    Retail electricity choice in the United States allows end-use customers (including industrial, commercial, and residential customers) to buy electricity from competitive retail suppliers. This brochure offers an overview of retail electricity choice in the United States, and its impact on prices and renewable energy procurement. It concludes with three lessons learned from the U.S. retail market experience that may serve as a reference for other countries and regions taking steps towards retail electricity market liberalization.

  18. General conditions for electric power supply

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    If it is uncertain whether future power bills will be paid fully, it is admissible to take an action claiming a declaration which states that the electricity rate payment boycotter has no right to non-payment nor a right to withhold payment towards the electricity supply utility, and that the electricity supply utility has the right to stop energy supply because of reduced electricity rate payments effected and/or announced, and to denounce the contract without observing any term of notice. If the electricity buyer reduces a power bill to be paid without any legal grounds, the electricity supply utility has the right to stop power supplies and to denounce the power supply contract without observing any term of notice. The freedom of thought and the freedom of opinion must not be expressed by reducing power bills to be paid. Basic rights discontinue to be effective as soon as a contract or law is broken. A weighing of protected interests is not effected if the exercise of a basic law is unlawful. (orig./HP) [de

  19. Commercialization of an electric propulsion unit for ecological ice resurfacers

    Energy Technology Data Exchange (ETDEWEB)

    Giroux, M. [MG Service, L' Assomption, PQ (Canada); Sylvestre, P. [Environment Canada, Montreal, PQ (Canada)

    2000-03-01

    Community health departments (CHD) and the general public are greatly concerned about the air quality at indoor skating rinks. A solution now exists whereby municipalities can convert their internal combustion resurfacers to electricity, using a system proposed by MG Service. This electric propulsion unit was developed and designed by MG Service, in conjunction with the Centre d'experimentation des vehicules electriques du Quebec (CEVEQ) and TPR Inc., an engineering firm. The main advantage of this technology is the ease of integration into the chassis of conventional resurfacers currently in use throughout the various municipalities. The propulsion unit is battery-powered and designed to replace the internal combustion engine. As a result, it eliminates carbon monoxide and nitrogen dioxide emissions, and more than meets the requirements set by health boards with regard to air quality at indoor skating rinks. Recyclable, maintenance-free and manufactured according to the standards set by the Underwriters Laboratories of Canada (ULC), the gel-sealed batteries display great advantages. The cost effectiveness of the electric propulsion unit is more impressive when considering that electricity is clean and costs five times less than conventional fuels currently in use. Regular verifications and calibrations are not required and the maintenance is minimal. The ventilation requirements are also reduced, leading to savings in energy costs required for the aeration of the indoor skating rink. Finally, the elimination of tank rental and fuel costs represent an added benefit. A detailed description of the components is provided. Following a series of trials, the operators were impressed by the surface gripability, traction and manoeuvrability. The resurfacers also gave an impression of greater raw power and were very quiet and easy to use, resulting in better overall operation when compared to conventional resurfacers. 1 fig.

  20. Electric trade in the United States 1992

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    This publication, Electric Trade in the US 1992 (ELECTRA), is the fourth in a series of reports on wholesale power transactions prepared by the Electric Data Systems Branch, Survey Management Division, Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA). The electric trade data are published biennially. The first report presented 1986 data, and this report provides information on the electric power industry during 1992. The electric trade data collected and presented in this report furnish important information on the wholesale structure found within the US electric power industry. The patterns of interutility trade in the report support analyses of wholesale power transactions and provide input for a broader understanding of bulk power market issues that define the emerging national electric energy policies. The report includes information on the quantity of power purchased, sold, exchanged, and wheeled; the geographical locations of transactions and ownership classes involved; and the revenues and costs. Information on the physical transmission system are being included for the first time in this publication. Transmission data covering investor-owned electric utilities were shifted from the Financial Statistics of Selected Investor-Owned Electric Utilities to the ELECTRA publication. Some of the prominent features of this year`s report include information and data not published before on transmission lines for publicly owned utilities and transmission lines added during 1992 by investor-owned electric utilities.

  1. Electric trade in the United States 1992

    International Nuclear Information System (INIS)

    1994-09-01

    This publication, Electric Trade in the US 1992 (ELECTRA), is the fourth in a series of reports on wholesale power transactions prepared by the Electric Data Systems Branch, Survey Management Division, Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA). The electric trade data are published biennially. The first report presented 1986 data, and this report provides information on the electric power industry during 1992. The electric trade data collected and presented in this report furnish important information on the wholesale structure found within the US electric power industry. The patterns of interutility trade in the report support analyses of wholesale power transactions and provide input for a broader understanding of bulk power market issues that define the emerging national electric energy policies. The report includes information on the quantity of power purchased, sold, exchanged, and wheeled; the geographical locations of transactions and ownership classes involved; and the revenues and costs. Information on the physical transmission system are being included for the first time in this publication. Transmission data covering investor-owned electric utilities were shifted from the Financial Statistics of Selected Investor-Owned Electric Utilities to the ELECTRA publication. Some of the prominent features of this year's report include information and data not published before on transmission lines for publicly owned utilities and transmission lines added during 1992 by investor-owned electric utilities

  2. 77 FR 4650 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2012-01-31

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA... General Electric Company (GE) CF6-45 and CF6-50 series turbofan engines with certain low-pressure turbine... Compliance We estimate that this AD will affect 387 CF6-45 and CF6-50 series turbofan engines installed on...

  3. 78 FR 72567 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-12-03

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA... General Electric Company (GE) GE90-110B1 and -115B turbofan engines. This AD was prompted by multiple... turbofan engines with variable bypass valve (VBV) actuator fuel supply tube, part number (P/N) 2165M22P01...

  4. 78 FR 76045 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-12-16

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA... (AD) for General Electric Company (GE) GE90-110B1 and GE90-115B turbofan engines with certain high... turbofan engines with high pressure compressor (HPC) rotor stage 2-5 spools, part numbers (P/Ns) 351-103...

  5. 78 FR 38195 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-06-26

    ... Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... all General Electric Company (GE) GE90-110B1 and GE90-115B turbofan engines. This emergency AD was.... owners and operators of these GE90-110B1 and GE90-115B turbofan engines. This action was prompted by...

  6. Bulk energy storage increases United States electricity system emissions.

    Science.gov (United States)

    Hittinger, Eric S; Azevedo, Inês M L

    2015-03-03

    Bulk energy storage is generally considered an important contributor for the transition toward a more flexible and sustainable electricity system. Although economically valuable, storage is not fundamentally a "green" technology, leading to reductions in emissions. We model the economic and emissions effects of bulk energy storage providing an energy arbitrage service. We calculate the profits under two scenarios (perfect and imperfect information about future electricity prices), and estimate the effect of bulk storage on net emissions of CO2, SO2, and NOx for 20 eGRID subregions in the United States. We find that net system CO2 emissions resulting from storage operation are nontrivial when compared to the emissions from electricity generation, ranging from 104 to 407 kg/MWh of delivered energy depending on location, storage operation mode, and assumptions regarding carbon intensity. Net NOx emissions range from -0.16 (i.e., producing net savings) to 0.49 kg/MWh, and are generally small when compared to average generation-related emissions. Net SO2 emissions from storage operation range from -0.01 to 1.7 kg/MWh, depending on location and storage operation mode.

  7. Competitive Electricity Market Regulation in the United States: A Primer

    Energy Technology Data Exchange (ETDEWEB)

    Flores-Espino, Francisco [National Renewable Energy Lab. (NREL), Golden, CO (United States); Tian, Tian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chernyakhovskiy, Ilya [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chernyakhovskiy, Ilya [National Renewable Energy Lab. (NREL), Golden, CO (United States); Miller, Mackay [National Grid, Warwick (United Kingdom)

    2016-12-01

    The electricity system in the United States is a complex mechanism where different technologies, jurisdictions and regulatory designs interact. Today, two major models for electricity commercialization operate in the United States. One is the regulated monopoly model, in which vertically integrated electricity providers are regulated by state commissions. The other is the competitive model, in which power producers can openly access transmission infrastructure and participate in wholesale electricity markets. This paper describes the origins, evolution, and current status of the regulations that enable competitive markets in the United States.

  8. Green electricity policies in the United States: case study

    International Nuclear Information System (INIS)

    Menz, Fredric C.

    2005-01-01

    While there has been interest in promoting the use of renewable energy in electricity production for a number of years in the United States, the market share of non-hydro renewable energy sources in electricity production has remained at about 2 percent over the past decade. The paper reviews the principal energy resources used for electricity production, considers the changing regulatory environment for the electricity industry, and describes government policies that have been used to promote green electricity in the United States, with an emphasis on measures adopted by state governments. Factors influencing the development of green power markets are also discussed, including underlying economic issues, public policy measures, the regulatory environment, external costs, and subsidies. Without significant increases in fossil fuel prices, much more stringent environmental regulations, or significant changes in electricity customer preferences, green electricity markets are likely to develop slowly in the United States

  9. United States electric industry : restructuring in review

    International Nuclear Information System (INIS)

    Slocum Hollis, S.

    2004-01-01

    This paper provides a detailed review of the United States electric power industry. The aim of the review was to clarify and better define current industry procedures and practices in light of significant and recent restructuring. In addition, recent bankruptcies and the power blackout in 2003 have raised concerns over industry practices. Issues concerning Independent System Operators (ISO) and regional transmission organizations were evaluated, with reference to an evolution and implementation of Regional Transmission Organization (RTO) policy, including a cost-benefit analysis. A background of RTO formations was provided with reference to consolidation, selection process and transfer of assets. Standard market design, network access and pricing issues were reviewed, as well as market and reliability concerns. Issues concerning affiliate treatment, shortages and the effect of sale of securities were presented. Various approaches to congestion management were examined, with examples from California and New England. Market monitoring issues, investigations and hearings were also examined, with examples and orders, including details of refunds. Measures to improve reliability were reviewed, including: management systems, benefit margins, requirements, assurance agreements and reserve markets. Issues concerning information access were presented, including: Open Access Same-time Information System (OASIS) requirements; tagging; standard business practices and protocols; and quarterly report practices and protocols. Interconnection policies were reviewed with reference to applicability, service options and pricing. The issue of variations was examined, with case examples concerning cost allocation, contract rights and treatment of specific costs. Jurisdiction issues concerning corporate realignments and power exchanges were presented, as well as specific services and state-federal relations. Issues concerning mergers and merger policy were also discussed, with reference

  10. 78 FR 19983 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-04-03

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA... Electric Company (GE) CF34-8C and CF34-8E turbofan engines with certain part numbers (P/N) of operability...-8E6, and CF34-8E6A1 turbofan engines, with an operability bleed valve (OBV) part number (P/N...

  11. 78 FR 50320 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-08-19

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA... Electric Company (GE) model GEnx-2B67B turbofan engines with booster anti-ice (BAI) air duct, part number...-2B67 turbofan engine be removed from the Applicability section of this AD. The commenters noted that...

  12. 77 FR 3088 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2012-01-23

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA... Electric Company (GE) CF34-10E series turbofan engines. This AD was prompted by a report of heavy wear... turbofan engines installed on airplanes of U.S. registry. We also estimate that it will take about 8 work...

  13. Local electric dipole moments: A generalized approach.

    Science.gov (United States)

    Groß, Lynn; Herrmann, Carmen

    2016-09-30

    We present an approach for calculating local electric dipole moments for fragments of molecular or supramolecular systems. This is important for understanding chemical gating and solvent effects in nanoelectronics, atomic force microscopy, and intensities in infrared spectroscopy. Owing to the nonzero partial charge of most fragments, "naively" defined local dipole moments are origin-dependent. Inspired by previous work based on Bader's atoms-in-molecules (AIM) partitioning, we derive a definition of fragment dipole moments which achieves origin-independence by relying on internal reference points. Instead of bond critical points (BCPs) as in existing approaches, we use as few reference points as possible, which are located between the fragment and the remainder(s) of the system and may be chosen based on chemical intuition. This allows our approach to be used with AIM implementations that circumvent the calculation of critical points for reasons of computational efficiency, for cases where no BCPs are found due to large interfragment distances, and with local partitioning schemes other than AIM which do not provide BCPs. It is applicable to both covalently and noncovalently bound systems. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. General Electric : Immelt surve all / Jena McGregor

    Index Scriptorium Estoniae

    McGregor, Jena

    2008-01-01

    Ettevõtte General Electric juht Jeffrey R. Immelt võitleb selle nimel, et taastada usaldus firma vastu, kuna laenukriis ja kehvad aktsiahinnad on tekitanud olukorra, kus investorid avaldavad suurt survet ettevõtte juhile. Lisa: GE kindralid

  15. General Electric tõrjus Microsofti liidrikohalt / Kaja Koovit

    Index Scriptorium Estoniae

    Koovit, Kaja, 1968-

    2001-01-01

    General Electric võttis Microsofti ees liidrikoha maailma suurima turuväärtusega ettevõtte edetabelis FT500. Tabelid: Maailma suurima turukapitalisatsiooniga ettevõtete TOP25, Skandinaavia firmade turuväärtuse TOP10

  16. 78 FR 47534 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-08-06

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA... directive (AD) 2013-14-51 for General Electric Company (GE) GE90-110B1 and GE90-115B turbofan engines with... all known U.S. owners and operators of GE90-110B1 and GE90-115B turbofan engines. AD 2013-14-51...

  17. 78 FR 24671 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-04-26

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA... certain General Electric Company (GE) CF6-80C2 series turbofan engines. That AD currently requires.../B1F/B2F/B4F/B6F/B7F/D1F turbofan engines with any of the following installed: (1) Fuel tube, part...

  18. AIR POLLUTION: Emissions from Older Electricity Generating Units

    National Research Council Canada - National Science Library

    2002-01-01

    .... While fossil fuels-coal, natural gas, and oil-account for more than two thirds of our electricity, generating units that burn these fuels are major sources of airborne emissions that pose human...

  19. Stroke Unit: General principles and standards

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Topçuoğlu

    2015-04-01

    Full Text Available Evidence-based medicinal methods have convincingly shown that stroke unit approach reduces mortality and disability rates, improves the quality of life and economic burden resulting from acute ischemic and hemorrhagic stroke. Any contemporary stroke system of care cannot be successful without putting the stroke unit concept in the center of its organization. Stroke units are the main elements of primary and comprehensive stroke centers. As a modernization process, this article focuses on practical issues and suggestions related to integration of the stroke unit approach to a regionally organized stroke system of care for perusal by not only national health authorities and service providers, but also neurologists. Stroke unit quality metrics revisited herein are of critical importance for hospitals establishing or renovating primary and comprehensive stroke centers.

  20. An integrated DEA-COLS-SFA algorithm for optimization and policy making of electricity distribution units

    International Nuclear Information System (INIS)

    Azadeh, A.; Ghaderi, S.F.; Omrani, H.; Eivazy, H.

    2009-01-01

    This paper presents an integrated data envelopment analysis (DEA)-corrected ordinary least squares (COLS)-stochastic frontier analysis (SFA)-principal component analysis (PCA)-numerical taxonomy (NT) algorithm for performance assessment, optimization and policy making of electricity distribution units. Previous studies have generally used input-output DEA models for benchmarking and evaluation of electricity distribution units. However, this study proposes an integrated flexible approach to measure the rank and choose the best version of the DEA method for optimization and policy making purposes. It covers both static and dynamic aspects of information environment due to involvement of SFA which is finally compared with the best DEA model through the Spearman correlation technique. The integrated approach would yield in improved ranking and optimization of electricity distribution systems. To illustrate the usability and reliability of the proposed algorithm, 38 electricity distribution units in Iran have been considered, ranked and optimized by the proposed algorithm of this study.

  1. Outdoor unit construction for an electric heat pump

    Science.gov (United States)

    Draper, R.; Lackey, R.S.

    1984-09-11

    The outdoor unit for an electric heat pump is provided with an upper portion containing propeller fan means for drawing air through the lower portion containing refrigerant coil means in the form of four discrete coils connected together in a subassembly forming a W shape, the unit being provided with four adjustable legs which are retracted in shipment, and are adjusted on site to elevate the unit to a particular height suitable for the particular location in which the unit is installed. 4 figs.

  2. Guide to federal regulation of sales of imported electricity in Canada, Mexico and the United States

    International Nuclear Information System (INIS)

    2005-01-01

    This Guide to Federal Regulation of Sales of Imported Electricity in Canada, Mexico, and the United States promotes cross-border electricity trade. It provides information on federal regulation of cross-border electricity trade and is intended to be used together with a companion guide called the North American Regulation of International Electricity Trade which outlines regulations for the construction and operation of cross-border power lines and the permitting requirements for electricity exports and imports between Canada, Mexico and the United States. The guide outlines the basic elements of the general federal regulatory process that applies to a given North American cross-border electricity trade. It offers an improved understanding of the applicable country's federal regulatory regime. Different federal government agencies within each country may regulate different aspects of a particular cross-border electricity trade. This guide does not examine the requirements that may apply at the state or provincial government levels. Rather, it is a collaborative effort of the 3 national energy departments and energy regulators that support the Experts Group on Electricity Regulatory Issues, a specialized unit assembled by the North American Energy Working Group (NAEWG). It was noted that the energy policies and regulations of each nation can change periodically

  3. 77 FR 48110 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2012-08-13

    ... Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed... certain General Electric Company (GE) CF6-80C2 series turbofan engines. The existing AD requires... 2000-04-14, Amendment 39-11597 (65 FR 10698, February 29, 2000), for all GE CF6-80C2 series turbofan...

  4. 76 FR 64844 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2011-10-19

    ... Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed... General Electric Company (GE) CF6-45 and CF6-50 series turbofan engines with certain low-pressure turbine... series turbofan engines with certain LPT rotor stage 3 disks installed. That AD requires initial and...

  5. 77 FR 58471 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2012-09-21

    ... Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA.../P1, GEnx-1B75/P1, GEnx- 2B67, and GEnx-2B67B turbofan engines. This AD requires initial and... this AD will affect 11 GE GEnx turbofan engines installed on airplanes of U.S. registry. We also...

  6. 77 FR 76977 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2012-12-31

    ... Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Supplemental notice... proposed airworthiness directive (AD) for certain General Electric Company (GE) CF6-80C2 series turbofan... part 39 to include an AD that would apply to certain GE CF6-80C2 series turbofan engines. That NPRM...

  7. The metre-kilogram-second system of electrical units

    CERN Document Server

    Sas, R K

    1947-01-01

    Introduction ; electrostatic units, electromagnetic units, and practical units ; magnetic intensity and flux density ; rationalization ; tribulations of the student ; metres and kilograms in general and in mechanics ; pulse and aperture ; magnetostatics ; steady currents ; electrostatics ; resistance ; electromagnetic induction ; determination of Eo. capacity formulae ; field ; electrons and moving charges ; quantum theory ; memory assisted by the M.K.S. system ; short account of M.K.S. units ; list of formulae

  8. Capsule Units for Guitar, Autoharp, Recorder. Elementary General Music.

    Science.gov (United States)

    Sweet, Debbie

    An intermediate-level general music unit provides introductory lessons for the autoharp, guitar, and recorder. In the autoharp unit, chording is approached by first using a one-chord song and proceeding to three-chord songs. The guitar unit introduces chord symbols and tablatures and helps students gain familiarity with the parts of the…

  9. Envisioning a renewable electricity future for the United States

    International Nuclear Information System (INIS)

    Mai, Trieu; Mulcahy, David; Hand, M. Maureen; Baldwin, Samuel F.

    2014-01-01

    This paper presents high renewable electricity penetration scenarios in the United States using detailed capacity expansion modeling that is designed to properly account for the variability and uncertainty of wind and solar resources. The scenarios focus solely on the electricity system, an important sector within the larger energy sector, and demonstrate long-term visions of a U.S. power system where renewable technologies, including biomass, geothermal, hydropower, solar, and wind, contribute 80% of 2050 annual electricity, including 49–55% from wind and solar photovoltaic generation. We present the integration challenges of achieving this high penetration and characterize the options to increase grid flexibility to manage variability. Four high renewable pathways are modeled and demonstrate the robustness and diversity of renewable options. We estimate 69–82% annual greenhouse gas emission reductions and 3%–30% incremental electricity price increases associated with reaching 80%-by-2050 renewable electricity relative to reference scenarios. This paper affirms and strengthens similar analysis from the Renewable Electricity Futures study by using an improved model and updated data to better reflect investment and dispatch decisions under current outlooks for the U.S. electricity sector. - Highlights: • We model high renewable electricity scenarios for the U.S. electricity sector. • The mix of technologies will depend on future costs and system conditions. • Integration challenges and flexibility options are presented. • We estimate an incremental electricity price increase of 3–30% to achieve 80% RE (renewable electricity). • We estimate 69–82% reduction in annual carbon emissions with 80% RE

  10. Standard technical specifications for General Electric boiling water reactors

    International Nuclear Information System (INIS)

    1979-08-01

    This Standard Technical Specification (STS) has been structured for the broadest possible use on General Electric plants currently being reviewed for an Operating License. Optional specifications are provided for those features and systems which may be included in individual plant designs but are not generic in their scope of application. This revision of the GE-STS does not typically include requirements which may be added or revised as a result of the NRC staff's further review of the Three Mile Island incident

  11. Motor unit recruitment during neuromuscular electrical stimulation: a critical appraisal.

    Science.gov (United States)

    Bickel, C Scott; Gregory, Chris M; Dean, Jesse C

    2011-10-01

    Neuromuscular electrical stimulation (NMES) is commonly used in clinical settings to activate skeletal muscle in an effort to mimic voluntary contractions and enhance the rehabilitation of human skeletal muscles. It is also used as a tool in research to assess muscle performance and/or neuromuscular activation levels. However, there are fundamental differences between voluntary- and artificial-activation of motor units that need to be appreciated before NMES protocol design can be most effective. The unique effects of NMES have been attributed to several mechanisms, most notably, a reversal of the voluntary recruitment pattern that is known to occur during voluntary muscle contractions. This review outlines the assertion that electrical stimulation recruits motor units in a nonselective, spatially fixed, and temporally synchronous pattern. Additionally, it synthesizes the evidence that supports the contention that this recruitment pattern contributes to increased muscle fatigue when compared with voluntary actions and provides some commentary on the parameters of electrical stimulation as well as emerging technologies being developed to facilitate NMES implementation. A greater understanding of how electrical stimulation recruits motor units, as well as the benefits and limitations of its use, is highly relevant when using this tool for testing and training in rehabilitation, exercise, and/or research.

  12. Main unit electrical protection at Sizewell 'B' power station

    International Nuclear Information System (INIS)

    Fischer, A.; Keates, T.

    1992-01-01

    For any power station, reliable electrical protection of the main generating units (generators plus generator transformers) has important commercial implications. Spurious trips cause loss of generation and consequent loss of revenue, while failure to rapidly isolate a fault leads to unnecessary damage and again, loss of generation and revenue. While these conditions apply equally to Sizewell B there are additional factors to be taken into consideration. A spurious trip of a main generating unit may lead to a trip of the reactor with an associated challenge to the shutdown and core cooling plant. The generator transformers, besides exporting power from the generators to the 400 kV National Grid, also import power from the Grid to the 11 kV Main Electrical System, which in turn is the preferred source of supply to the Essential Electrical System. The Main Unit Protection is designed to clear generator faults leaving this off-site power route intact. Hence failure to operate correctly could affect the integrity of the Essential Electrical Supplies. (Author)

  13. Report from UNSCEAR to the United Nations General Assembly

    International Nuclear Information System (INIS)

    2001-01-01

    Over the past few years, the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) has undertaken a broad review of the sources and effects of ionizing radiation. The result of this work has presented for the general reader in the 2000 Report to the General Assembly. This report with the supporting scientific annexes, which are aimed at the general scientific community, was published as 'Sources and Effects of Ionizing Radiation, United Nations Scientific Committee on the Effects of Atomic Radiation 2000 report to the General Assembly, with scientific annexes'

  14. NCHS - Births and General Fertility Rates: United States

    Data.gov (United States)

    U.S. Department of Health & Human Services — This dataset includes crude birth rates and general fertility rates in the United States since 1909. The number of states in the reporting area differ historically....

  15. Status of electricity trading in the United States

    International Nuclear Information System (INIS)

    McMillan, P.H.

    1999-01-01

    The evolution of the energy marketplace in the United States is presented in a series of overhead viewgraphs. The influencing factors of energy trading are described as being supply concentration, rate cross subsidization, price volatility, physics, stranded investment, market structure and value drivers. A map depicting trading hubs and market structures is included, along with an outline of the key characteristics of a successful market hub. Gas-electric interface issues are also discussed. It was stated that contrary to conventional wisdom that as gas and electricity markets converge, traders will routinely cross-hedge gas and power, the practical reality is that volatility of the gas to electricity basis spread actually limits hedging opportunities. A winning strategy should include thorough fundamental and technical analysis; every trade or position should have a well thought-out exit strategy; get closer to physical assets; and be careful across regional hubs and commodities. 2 tabs., 7 figs

  16. Evaluation of Waterford Steam Electric Station Unit 3 technical specifications

    International Nuclear Information System (INIS)

    Baxter, D.E.; Bruske, S.J.

    1985-09-01

    This document was prepared for the Nuclear Regulatory Commission (NRC) to assist them in determining whether the Waterford Steam Electric Station Unit 3 Technical Specifications (T/S), which govern plant systems configurations and operations, are in conformance with the requirements of the Final Safety Analysis Report (FSAR) as amended, and the requirements of the Safety Evaluation Report (SER) as supplemented. A comparative audit of the FSAR as amended, and the SER as supplemented was performed with the Waterford T/S. Several discrepancies were identified and subsequently resolved by the cognizant NRC reviewer. Pending completion of the resolutions noted in Part 3 of this report, the Waterford Steam Electric Station Unit 3 T/S, to the extent reviewed, are in conformance with the FSAR and SER

  17. New Generation General Purpose Computer (GPC) compact IBM unit

    Science.gov (United States)

    1991-01-01

    New Generation General Purpose Computer (GPC) compact IBM unit replaces a two-unit earlier generation computer. The new IBM unit is documented in table top views alone (S91-26867, S91-26868), with the onboard equipment it supports including the flight deck CRT screen and keypad (S91-26866), and next to the two earlier versions it replaces (S91-26869).

  18. General types of idiomatic verbal units in English and Swahili

    Directory of Open Access Journals (Sweden)

    Людмила Алексеевна Семенкова

    2012-09-01

    Full Text Available The article deals with the comparative analysis of the idiomatic verbal units-word combination of the two typologically different languages - English and Swahili: As a result a number of general syntactic types of their idiomatic verbal units are determined.

  19. Electrical stimulation of transplanted motoneurons improves motor unit formation

    Science.gov (United States)

    Liu, Yang; Grumbles, Robert M.

    2014-01-01

    Motoneurons die following spinal cord trauma and with neurological disease. Intact axons reinnervate nearby muscle fibers to compensate for the death of motoneurons, but when an entire motoneuron pool dies, there is complete denervation. To reduce denervation atrophy, we have reinnervated muscles in Fisher rats from local transplants of embryonic motoneurons in peripheral nerve. Since growth of axons from embryonic neurons is activity dependent, our aim was to test whether brief electrical stimulation of the neurons immediately after transplantation altered motor unit numbers and muscle properties 10 wk later. All surgical procedures and recordings were done in anesthetized animals. The muscle consequences of motoneuron death were mimicked by unilateral sciatic nerve section. One week later, 200,000 embryonic day 14 and 15 ventral spinal cord cells, purified for motoneurons, were injected into the tibial nerve 10–15 mm from the gastrocnemii muscles as the only neuron source for muscle reinnervation. The cells were stimulated immediately after transplantation for up to 1 h using protocols designed to examine differential effects due to pulse number, stimulation frequency, pattern, and duration. Electrical stimulation that included short rests and lasted for 1 h resulted in higher motor unit counts. Muscles with higher motor unit counts had more reinnervated fibers and were stronger. Denervated muscles had to be stimulated directly to evoke contractions. These results show that brief electrical stimulation of embryonic neurons, in vivo, has long-term effects on motor unit formation and muscle force. This muscle reinnervation provides the opportunity to use patterned electrical stimulation to produce functional movements. PMID:24848463

  20. United States/Mexico electricity exchanges. [History, incentives, and constraints

    Energy Technology Data Exchange (ETDEWEB)

    None,

    1980-05-01

    As a result of the agreement between the respective presidents, a joint study was undertaken to analyze the possibilities of increasing the international electricity exchange between the two countries. Responsibility for this undertaking was assigned to the United States Department of Energy (DOE) and to the Direccion de Energia de Mexico (DEM) through the Comision Federal de Electricidad (CFE). Representatives from Mexico and the US were chosen from the regional utilities along the border between the two countries and made up working groups that particiated in the study. With the support of both governments, and a high degree of cooperation between the two countries, work on the study was completed within fourteen months The completion of the study has been a major step in broadening the base of bilateral energy relations. the study highlights the opportunities for increased electricity exchanges, which could increase cooperation along the common border. Expansion of electricity interchange could offer substantial economic benefit to both countries, both directly and indirectly. Direct benefits include increased reliability of electric power and cost savings through economies of scale and diversity of peak demand patterns. Indirect benefits include improved economic and employment opportunities, especially in the border areas of both countries. This report provides background on the history of past exchanges and the characteristics of the US and Mexico electric systems, a summary of opportunities and incentives, and suggestions for procedures to remove obstacles and constraints.

  1. Recombinative generalization of subword units using matching to sample.

    LENUS (Irish Health Repository)

    Mahon, Catherine

    2010-01-01

    The purpose of the current study was to develop and test a computerized matching-to-sample (MTS) protocol to facilitate recombinative generalization of subword units (onsets and rimes) and recognition of novel onset-rime and onset-rime-rime words. In addition, we sought to isolate the key training components necessary for recombinative generalization. Twenty-five literate adults participated. Conditional discrimination training emerged as a crucial training component. These findings support the effectiveness of MTS in facilitating recombinative generalization, particularly when conditional discrimination training with subword units is used.

  2. Electric motor drive unit, especially adjustment drive for vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Litterst, P

    1980-05-29

    An electric motor drive unit, particularly an adjustment drive for vehicles with at least two parallel drive shafts is described, which is compact and saves space, and whose manufacturing costs are low compared with those of well-known drive units of this type. The drive unit contains a suitable number of magnet systems, preferably permanent magnet systems, whose pole axes are spaced and run parallel. The two pole magnet systems have diametrically opposite shell-shaped segments, to which the poles are fixed. In at least one magnet system the two segments are connected by diametrically opposite flat walls parallel to the pole axes to form a single magnetic circuit pole housing. The segments of at least one other magnet system are arranged on this pole housing so that one of these flat walls is a magnetically conducting, connecting component of the magnetic circuit of the other magnet system.

  3. Identifying future electricity-water tradeoffs in the United States

    International Nuclear Information System (INIS)

    Sovacool, Benjamin K.; Sovacool, Kelly E.

    2009-01-01

    Researchers for the electricity industry, national laboratories, and state and federal agencies have begun to argue that the country could face water shortages resulting from the addition of thermoelectric power plants, but have not attempted to depict more precisely where or how severe those shortages will be. Using county-level data on rates of population growth collected from the US Census Bureau, utility estimates of future planned capacity additions in the contiguous United States reported to the US Energy Information Administration, and scientific estimates of anticipated water shortages provided from the US Geologic Survey and National Oceanic and Atmospheric Administration, this paper highlights the most likely locations of severe shortages in 22 counties brought about by thermoelectric capacity additions. Within these areas are some 20 major metropolitan regions where millions of people live. After exploring the electricity-water nexus and explaining the study's methodology, the article then focuses on four of these metropolitan areas - Houston, Texas; Atlanta, Georgia; Las Vegas, Nevada; New York, New York - to deepen an understanding of the water and electricity challenges they may soon be facing. It concludes by identifying an assortment of technologies and policies that could respond to these electricity-water tradeoffs.

  4. Identifying future electricity-water tradeoffs in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Sovacool, Benjamin K. [Energy Governance Program, Centre on Asia and Globalisation, Lee Kuan Yew School of Public Policy, National University of Singapore (Singapore); Sovacool, Kelly E. [Department of Geography, Virginia Polytechnic Institute and State University, Blacksburg, VA (United States)

    2009-07-15

    Researchers for the electricity industry, national laboratories, and state and federal agencies have begun to argue that the country could face water shortages resulting from the addition of thermoelectric power plants, but have not attempted to depict more precisely where or how severe those shortages will be. Using county-level data on rates of population growth collected from the US Census Bureau, utility estimates of future planned capacity additions in the contiguous United States reported to the US Energy Information Administration, and scientific estimates of anticipated water shortages provided from the US Geologic Survey and National Oceanic and Atmospheric Administration, this paper highlights the most likely locations of severe shortages in 22 counties brought about by thermoelectric capacity additions. Within these areas are some 20 major metropolitan regions where millions of people live. After exploring the electricity-water nexus and explaining the study's methodology, the article then focuses on four of these metropolitan areas - Houston, Texas; Atlanta, Georgia; Las Vegas, Nevada; New York, New York - to deepen an understanding of the water and electricity challenges they may soon be facing. It concludes by identifying an assortment of technologies and policies that could respond to these electricity-water tradeoffs. (author)

  5. Installation of new Generation General Purpose Computer (GPC) compact unit

    Science.gov (United States)

    1991-01-01

    In the Kennedy Space Center's (KSC's) Orbiter Processing Facility (OPF) high bay 2, Spacecraft Electronics technician Ed Carter (right), wearing clean suit, prepares for (26864) and installs (26865) the new Generation General Purpose Computer (GPC) compact IBM unit in Atlantis', Orbiter Vehicle (OV) 104's, middeck avionics bay as Orbiter Systems Quality Control technician Doug Snider looks on. Both men work for NASA contractor Lockheed Space Operations Company. All three orbiters are being outfitted with the compact IBM unit, which replaces a two-unit earlier generation computer.

  6. Psychiatric units in Brazilian general hospitals: a growing philanthropic field.

    Science.gov (United States)

    Botega, Neury José

    2002-06-01

    Some countries, mainly in North America and Europe, have adopted psychiatric wards in the general hospital as an alternative to the classic psychiatric hospital. In Brazil there are 6,169 general hospitals, 1.3% of which with a psychiatric unit. This service strategy is scarcely developed in the country and comprises only 4% of all psychiatric admissions. There was no information on the facilities and functioning of the psychiatric units in general hospitals. To determine the main characteristics of psychiatric units in Brazilian general hospitals and to assess the current trends in the services provided. A mailing survey assessed all 94 Brazilian general hospitals which made psychiatric admissions. A two-page questionnaire was designed to determine the main characteristics of each institution and of the psychiatric unit. Seventy-nine (84%) questionnaires were returned. In contrast to the 1970s and 1980s, in the last decade the installation of psychiatric units has spread to smaller philanthropic institutions that are not linked to medical schools. A fifth of hospitals admit psychiatric patients to medical wards because there is no specialist psychiatric ward. They try to meet all the local emergency demands, usually alcohol-dependent patients who need short term admission. This could signal the beginning of a program through which mental health professionals may become an integral part of general health services. The inauguration of psychiatric wards in philanthropic hospitals, as well as the admission of psychiatric patients in their medical wards, is a phenomenon peculiar to this decade. The installation of psychiatric services in these and other general hospitals would overcome two of major difficulties encountered: prejudice and a lack of financial resources.

  7. Standard Technical Specifications, General Electric plants, BWR/4

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/4, and documents the positions of the Nuclear Regulatory Commission based on the BWR Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power specifications. This report contains three volumes. This document, Volume 2, contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS

  8. Patient stress in intensive care: comparison between a coronary care unit and a general postoperative unit

    Science.gov (United States)

    Dias, Douglas de Sá; Resende, Mariane Vanessa; Diniz, Gisele do Carmo Leite Machado

    2015-01-01

    Objective To evaluate and compare stressors identified by patients of a coronary intensive care unit with those perceived by patients of a general postoperative intensive care unit. Methods This cross-sectional and descriptive study was conducted in the coronary intensive care and general postoperative intensive care units of a private hospital. In total, 60 patients participated in the study, 30 in each intensive care unit. The stressor scale was used in the intensive care units to identify the stressors. The mean score of each item of the scale was calculated followed by the total stress score. The differences between groups were considered significant when p < 0.05. Results The mean ages of patients were 55.63 ± 13.58 years in the coronary intensive care unit and 53.60 ± 17.47 years in the general postoperative intensive care unit. For patients in the coronary intensive care unit, the main stressors were “being in pain”, “being unable to fulfill family roles” and “being bored”. For patients in the general postoperative intensive care unit, the main stressors were “being in pain”, “being unable to fulfill family roles” and “not being able to communicate”. The mean total stress scores were 104.20 ± 30.95 in the coronary intensive care unit and 116.66 ± 23.72 (p = 0.085) in the general postoperative intensive care unit. When each stressor was compared separately, significant differences were noted only between three items. “Having nurses constantly doing things around your bed” was more stressful to the patients in the general postoperative intensive care unit than to those in the coronary intensive care unit (p = 0.013). Conversely, “hearing unfamiliar sounds and noises” and “hearing people talk about you” were the most stressful items for the patients in the coronary intensive care unit (p = 0.046 and 0.005, respectively). Conclusion The perception of major stressors and the total stress score were similar between patients

  9. General surgical admissions in the intensive care unit in Ibadan ...

    African Journals Online (AJOL)

    Objectives:The Intensive Care Unit (ICU) has improved patient outcome in complex surgeries while the costs of maintaining services are high. ICU services in developing countries are often inadequate due to lack of funds. This study reviews the pattern and outcomes of General Surgical patients admitted to the ICU of our ...

  10. Transmutor demo unit and thermal into electrical energy transformation problems

    International Nuclear Information System (INIS)

    Matal, O.; Fiedler, J.

    1999-01-01

    In the three circuits layout of the transmutor the heat is transferred from the primary through the secondary circuits by a favourable heat carrier into the tertiary circuit where the thermal into electrical energy transformation in turbo-generator comes into force. Properties as well as parameters of the heat carrier in the secondary circuit affect basically both the conceptual layout of the tertiary circuit and consequently investments costs for its realization and the effectiveness of the transformation of thermal into electrical energy. For several heat carriers considered for the transmutor secondary circuit particular tertiary circuit concepts for the demonstration transmutor unit of approx. 15 W thermal power rate are analyzed, layout features and possibilities of turbogenerator selection are commented and investment costs as well as effectiveness of thermal into electrical energy transformation are estimated. Some of the results are as follows: (i) Heat carrier properties influence thermodynamics of the TDU water/steam cycle substantially. One of the dominant parameters is the melting (freezing) temperature of the heat carrier. (ii) Heat carrier properties influence investment costs of components of the TDU tertiary circuit substantially. Dominantly influenced are costs of the steam generator, steam turbine and high pressure regeneration system. (iii) If the heat carrier has to be a molten salt than a salt with a low melting temperature is recommended to be selected, for example KHF2. (iv) Eutectic alloy Pb-Bi as the heat carrier serves changes to design the TDU with efficient thermodynamics, with acceptable low investment costs of the tertiary as well as secondary circuit components and with an acceptable level of the nuclear safety

  11. 76 FR 70166 - Electrical Standards for Construction and General Industry; Extension of the Office of Management...

    Science.gov (United States)

    2011-11-10

    ...] Electrical Standards for Construction and General Industry; Extension of the Office of Management and Budget... contained in the Electrical Standards for Construction (29 CFR part 1926, Subpart K) and for General... maintenance of electric utilization equipment that prevent death and serious injuries among construction and...

  12. The ATLAS Trigger Algorithms for General Purpose Graphics Processor Units

    CERN Document Server

    Tavares Delgado, Ademar; The ATLAS collaboration

    2016-01-01

    The ATLAS Trigger Algorithms for General Purpose Graphics Processor Units Type: Talk Abstract: We present the ATLAS Trigger algorithms developed to exploit General­ Purpose Graphics Processor Units. ATLAS is a particle physics experiment located on the LHC collider at CERN. The ATLAS Trigger system has two levels, hardware-­based Level 1 and the High Level Trigger implemented in software running on a farm of commodity CPU. Performing the trigger event selection within the available farm resources presents a significant challenge that will increase future LHC upgrades. are being evaluated as a potential solution for trigger algorithms acceleration. Key factors determining the potential benefit of this new technology are the relative execution speedup, the number of GPUs required and the relative financial cost of the selected GPU. We have developed a trigger demonstrator which includes algorithms for reconstructing tracks in the Inner Detector and Muon Spectrometer and clusters of energy deposited in the Cal...

  13. Standard Technical Specifications, General Electric plants, BWR/4

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/6, and documents the positions of the Nuclear Regulatory Commission based on the B ampersand W Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. This document Volume 3, contains the Bases for Sections 3.4--3.10 of the improved STS

  14. Standard Technical Specifications, General Electric Plants, BWR/6

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/6, and documents the positions of the Nuclear Regulatory Commission based on the B ampersand W Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. This document Volume 1, contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4--3.10 of the improved STS

  15. Standard Technical Specifications, General Electric plants, BWR/4

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/6, and documents the positions of the Nuclear Regulatory Commission based on the BWR Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. This document Volume 1 contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4--3.10 of the improved STS

  16. Standard Technical Specifications, General Electric Plants, BWR/6

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/4, and documents the positions of the Nuclear Regulatory Commission based on the BWR Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3, contains the Bases for Sections 3.4--3.10 of the improved STS

  17. Generic risk insights for General Electric boiling water reactors

    International Nuclear Information System (INIS)

    Travis, R.; Taylor, J.; Chung, J.

    1991-05-01

    A methodology has been developed to extract generic risk-based information from probabilistic risk assessments (PRAs) of General Electric boiling water rectors and applying the insights gained to plants that have not been subjected to a PRA. The available risk assessments (six plants) were examined to identify the most probable, i.e., dominant accident sequences at each plants. The goal was to include all sequences which represented at least 80% of core damage frequency. If the same plant specific dominant accident sequence appeared within this boundary in at least two plant PRAs, the sequence was considered to be a representative sequence. Eight sequences met this definition. From these sequences, the most important component failures and human error that contributed to each sequence have been prioritized. Guidance is provided to prioritize the representative sequences and modify selected basic events that have been shown to be sensitive to the plant specific design or operating variations of the contributing PRAs. This risk-based guidance can be used for utility and NRC activities including operator training, maintenance, design review, and inspections. 13 refs., 6 tabs

  18. Standard Technical Specifications, General Electric plants, BWR/6

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/6, and documents the positions of the Nuclear Regulatory Commission based on the B ampersand W Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the Specifications for all chapters and sections of the improved STS. This document Volume 2, contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4--3.10 of the improved STS

  19. MINAC radiography performed on susquehanna Steam Electric Station Unit 1

    International Nuclear Information System (INIS)

    Bognet, J.C.

    1986-01-01

    Ten welds were volumetrically examined with a manual and automated ultrasonic (UT) system during a Susquehanna Steam Electric Station (SES) Unit 1 preservice inspection. The automated system had been recently developed and several problems were encountered in this first field application. The ten welds examined had a Sweepolet-to-Risor weld configuration, which further complicated the examination effort. This weld configuration has corrosion-resistant cladding applied to the outside and inside circumference and, as a result of an installation/removal/reinstallation sequence during plant construction, is often referred to as the double weld. After several attempts to obtain interpretable UT data failed (e.g., repeatable data), the examination effort was terminated. PP and L opted to pursue using the Miniature Linear Accelerator (MINAC) to perform radiographic examination. The results were referenced in the Susquehanna SES Unit 1 outage summary report and submitted to the NRC. The total effort was viewed as a complete success with no impact to the overall outage duration. All welds previously attempted by automated and manual UT were successfully examined using the MINAC

  20. A generalization information management system applied to electrical distribution

    Energy Technology Data Exchange (ETDEWEB)

    Geisler, K.I.; Neumann, S.A.; Nielsen, T.D.; Bower, P.K. (Empros Systems International (US)); Hughes, B.A.

    1990-07-01

    This article presents a system solution approach that meets the requirements being imposed by industry trends and the electric utility customer. Specifically, the solution addresses electric distribution management systems. Electrical distribution management is a particularly well suited area of application because it involves a high diversity of tasks, which are currently supported by a proliferation of automated islands. Islands of automation which currently exist include (among others) distribution operations, load management, automated mapping, facility management, work order processing, and planning.

  1. Improving the smoking patterns in a general hospital psychiatric unit

    Directory of Open Access Journals (Sweden)

    Celso Iglesias García

    2009-01-01

    Full Text Available Objectives: The purpose of the present paper is to evaluate the effects of a smoking ban in a general hospital psychiatric unit. Methods: We study the effects of smoking ban in 40 consecutive psychiatric inpatients. The staff registered socio-demographic and tobacco-related variables. We also registered any kind of behavioral effects of smoking ban.Results: The patients were willing to stop smoking during their hospital stay (with or without nicotine replacement with two mild behavioural incidences registered throughout the study. Conclusions: The benefits of non-smoking policy in a psychiatric unit can be significant. The introduction of smoking bans in psychiatric inpatients settings is possible and safe.

  2. Interleaved neuromuscular electrical stimulation: Motor unit recruitment overlap.

    Science.gov (United States)

    Wiest, Matheus J; Bergquist, Austin J; Schimidt, Helen L; Jones, Kelvin E; Collins, David F

    2017-04-01

    In this study, we quantified the "overlap" between motor units recruited by single pulses of neuromuscular electrical stimulation (NMES) delivered over the tibialis anterior muscle (mNMES) and the common peroneal nerve (nNMES). We then quantified the torque produced when pulses were alternated between the mNMES and nNMES sites at 40 Hz ("interleaved" NMES; iNMES). Overlap was assessed by comparing torque produced by twitches evoked by mNMES, nNMES, and both delivered together, over a range of stimulus intensities. Trains of iNMES were delivered at the intensity that produced the lowest overlap. Overlap was lowest (5%) when twitches evoked by both mNMES and nNMES produced 10% peak twitch torque. iNMES delivered at this intensity generated 25% of maximal voluntary dorsiflexion torque (11 Nm). Low intensity iNMES leads to low overlap and produces torque that is functionally relevant to evoke dorsiflexion during walking. Muscle Nerve 55: 490-499, 2017. © 2016 Wiley Periodicals, Inc.

  3. Electrical. Teacher's Guide. Building Maintenance Units of Instruction.

    Science.gov (United States)

    East Texas State Univ., Commerce. Occupational Curriculum Lab.

    This teaching guide on electrical building maintenance, one in a series of six publications designed for building maintenance instructors in Texas, is designed to give students an understanding of electricity in order to know how to make basic repairs to the electrical systems in a building. Introductory material provides teachers with information…

  4. Basic Guidelines to Introduce Electric Circuit Simulation Software in a General Physics Course

    Science.gov (United States)

    Moya, A. A.

    2018-01-01

    The introduction of electric circuit simulation software for undergraduate students in a general physics course is proposed in order to contribute to the constructive learning of electric circuit theory. This work focuses on the lab exercises based on dc, transient and ac analysis in electric circuits found in introductory physics courses, and…

  5. Hydropower Impacts on Electrical System Production Costs in the Southwest United States

    Directory of Open Access Journals (Sweden)

    Dominique M. Bain

    2018-02-01

    Full Text Available The Colorado River is an important natural resource for the Southwestern United States. Predicted climate change impacts include increased temperature, decreased rainfall and increased probability of drought in this region. Given the large amount of hydropower on the Colorado River and its importance to the bulk electricity system, this purpose of this study was to quantify the value hydropower in operating the electrical system, and examined changes in hydropower value and electricity costs under different possible future drought conditions and regional generation scenarios. The goal was to better understand how these scenarios affect operating costs of the bulk electrical system, as well as the value of the hydropower produced, and proposed a method for doing so. The calculated value of the hydroelectric power was nearly double the mean locational marginal price in the study area, about $73 to $75 for most scenarios, demonstrating a high value of the hydropower. In general, it was found that reduced water availability increased operating costs, and increased the value of the hydropower. A calculated value factor showed that when less hydroelectric power is available, the hydropower is more valuable. Furthermore, the value factor showed that the value of hydro increases with the addition of solar or the retirement of thermal generating resources.

  6. Use of general purpose graphics processing units with MODFLOW

    Science.gov (United States)

    Hughes, Joseph D.; White, Jeremy T.

    2013-01-01

    To evaluate the use of general-purpose graphics processing units (GPGPUs) to improve the performance of MODFLOW, an unstructured preconditioned conjugate gradient (UPCG) solver has been developed. The UPCG solver uses a compressed sparse row storage scheme and includes Jacobi, zero fill-in incomplete, and modified-incomplete lower-upper (LU) factorization, and generalized least-squares polynomial preconditioners. The UPCG solver also includes options for sequential and parallel solution on the central processing unit (CPU) using OpenMP. For simulations utilizing the GPGPU, all basic linear algebra operations are performed on the GPGPU; memory copies between the central processing unit CPU and GPCPU occur prior to the first iteration of the UPCG solver and after satisfying head and flow criteria or exceeding a maximum number of iterations. The efficiency of the UPCG solver for GPGPU and CPU solutions is benchmarked using simulations of a synthetic, heterogeneous unconfined aquifer with tens of thousands to millions of active grid cells. Testing indicates GPGPU speedups on the order of 2 to 8, relative to the standard MODFLOW preconditioned conjugate gradient (PCG) solver, can be achieved when (1) memory copies between the CPU and GPGPU are optimized, (2) the percentage of time performing memory copies between the CPU and GPGPU is small relative to the calculation time, (3) high-performance GPGPU cards are utilized, and (4) CPU-GPGPU combinations are used to execute sequential operations that are difficult to parallelize. Furthermore, UPCG solver testing indicates GPGPU speedups exceed parallel CPU speedups achieved using OpenMP on multicore CPUs for preconditioners that can be easily parallelized.

  7. High Electricity Demand in the Northeast U.S.: PJM Reliability Network and Peaking Unit Impacts on Air Quality.

    Science.gov (United States)

    Farkas, Caroline M; Moeller, Michael D; Felder, Frank A; Henderson, Barron H; Carlton, Annmarie G

    2016-08-02

    On high electricity demand days, when air quality is often poor, regional transmission organizations (RTOs), such as PJM Interconnection, ensure reliability of the grid by employing peak-use electric generating units (EGUs). These "peaking units" are exempt from some federal and state air quality rules. We identify RTO assignment and peaking unit classification for EGUs in the Eastern U.S. and estimate air quality for four emission scenarios with the Community Multiscale Air Quality (CMAQ) model during the July 2006 heat wave. Further, we population-weight ambient values as a surrogate for potential population exposure. Emissions from electricity reliability networks negatively impact air quality in their own region and in neighboring geographic areas. Monitored and controlled PJM peaking units are generally located in economically depressed areas and can contribute up to 87% of hourly maximum PM2.5 mass locally. Potential population exposure to peaking unit PM2.5 mass is highest in the model domain's most populated cities. Average daily temperature and national gross domestic product steer peaking unit heat input. Air quality planning that capitalizes on a priori knowledge of local electricity demand and economics may provide a more holistic approach to protect human health within the context of growing energy needs in a changing world.

  8. Experimental study of camel powered electricity generation unit

    Science.gov (United States)

    Jakhar, O. P.; Choudhary, Rahul Raj; Budaniya, Mukesh; Kumar, Ashish

    2018-05-01

    Developing nations are facing a huge gap in generation and demand of electricity across the world. In present scenario the demand of electricity is increasing day by day and the shortfall of electricity has become one of the major obstructions in the development of rural areas. There is a big gap between electricity supply and demand. In India it is very difficult that to give twenty four hours electric supply in rural areas. The traditional use of camel as draught animal, for the purpose of transport of goods and agricultural work, has been drastically reduced during last few decades, due to advancements and cheaper availability of mechanical machineries. In this research paper we experimentally studied the camel powered electricity generation system at National Research Centre on Camels (NRCC) Bikaner. Camel Energy in form of high torque low speed can be converted into low torque high speed through motion converting system i.e. gear and pulley mechanism for high RPM output. This high RPM (more than 3000) output is used for electricity generation. The electricity generated can be used directly or stored in the battery and later may be used whenever it is required either for DC light or AC light using inverter. According to experimental study a camel can comfortably generate electricity up to 1KW by rotating shaft. The complete set up for electricity generation using camel power has been designed, developed and physically commissioned at National Research Centre on Camels (NRCC) Bikaner.

  9. 78 FR 44899 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-07-25

    ... Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed... Electric Company (GE) GE90-110B1 and -115B turbofan engines. This proposed AD was prompted by multiple...) 2165M22P01, installed on GE90-110B1 and -115B turbofan engines. One of the leaks led to an under cowl engine...

  10. 78 FR 19628 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-04-02

    ... Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed... Electric Company (GE) GE90-76B, -85B, -90B, -94B, - 110B1, and -115B turbofan engines. This proposed AD was... of stage 1 HPT stator shroud distress resulting in engine removals on airplanes with GE90 turbofan...

  11. Power Processing Unit For Micro Satellite Electric Propulsion System

    Directory of Open Access Journals (Sweden)

    Savvas Spiridon

    2017-01-01

    Full Text Available The Micro Satellite Electric Propulsion System (MEPS program has been originated by the increasing need to provide a low-cost and low-power Electric Propulsion System (EPS for small satellites ( 92%, small size and weight and high reliability. Its functional modules and preliminary results obtained at breadboard level are also presented.

  12. The General Urban Plan of Casimcea territorial administrative unit, map of natural and anthropogenic risks

    Directory of Open Access Journals (Sweden)

    Sorin BĂNICĂ

    2013-08-01

    Full Text Available The General Urban Plan represents the legal ground for any development action proposed. After endorsement and approval as required by law, GUP is act of authority of local government for the area in which it applies. The aim is to establish priorities regulations applied in land use planning and construction of structures. In terms of geographical location, the administrative territory of Casimcea, Tulcea county, falls in the central Northwest Plateau Casimcei. This is the second unit of the Central Dobrogea Plateau. Geographical location in southeastern Romania, climatic and relief conditions and anthropogenic pressure, expose the village administrative territorial unit Casimcea, permanent susceptibility to produce natural and antropogenical risks. In this context, we identified the following categories of natural and anthropogenic risks: i natural risk phenomena (earthquakes, strong winds, heavy rains, floods caused by overflowing or precipitation, erosion of river banks and torrents, gravitational processes, rain droplet erosion and surface soil erosion; and ii anthropogenic risk phenomena (overgrazing, chemicals use in agriculture, road transport infrastructure and electricity, wind turbines for electricity production, waste deposits, agro-zootechnical complexs, and human cemeteries. Extending their surface was materialized by creating a map of natural and anthropogenic risk on Casimcea territorial administrative unit, explaining the share of potentially affected areas as territorial balance

  13. Feed-in tariff and market electricity price comparison. The case of cogeneration units in Croatia

    International Nuclear Information System (INIS)

    Uran, Vedran; Krajcar, Slavko

    2009-01-01

    In August 2007, the Government of the Republic of Croatia instituted a feed-in tariff system, requiring the Croatian Electricity Market Operator (HROTE) to off-take the electricity produced from renewable energy sources or cogeneration units fueled by natural gas. Analysis of the off-take electricity price range, which depends on the net electrical output and electricity market trends, indicates that it is more cost effective for cogeneration units greater than 1 MW to sell their electricity on the exchange market. This was confirmed by developing a mathematical model to calculate the cost-effectiveness ratio of a cogeneration unit. This ratio represents the relation between the profit spread, i.e. the difference between the profit generated from selling the electricity on the exchange market and the profit made from dispatching the electricity to HROTE, as well as the total investment costs. The model can be applied for changes in certain parameters, such as the net electrical output, volatility and spot electricity price. The Monte Carlo method is used to obtain the most probable cost-effectiveness ratio and average future electricity price. Together with these two economic parameters and market price analysis, it is possible to calculate and calibrate an acceptable off-take electricity price. (author)

  14. [Crisis unit at the general hospital: Determinants of further hospitalization].

    Science.gov (United States)

    Norotte, C; Omnès, C; Crozier, C; Verlyck, C; Romanos, M

    2017-10-01

    The availability of short-stay beds for brief admission (less than 72hours) of crisis patients presenting to the emergency room is a model that has gained a growing interest because it allows time for developing alternatives to psychiatric hospitalization and favors a maintained functioning in the community. Still, the determinants influencing the disposition decision at discharge after crisis intervention remain largely unexplored. The primary objective of this study was to determine the factors predicting aftercare dispositions at crisis unit discharge: transfer for further hospitalization or return to the community. Secondary objectives included the description of clinical and socio-demographic characteristics of patients admitted to the crisis unit upon presentation to the emergency room. All patients (n=255) admitted to the short-stay unit of the emergency department of Rambouillet General Hospital during a one-year period were included in the study. Patient characteristics were collected in a retrospective manner from medical records: patterns of referral, acute stressors, presenting symptoms, initial patient demand, Diagnostic and Statistical Manual, 5th edition (DSM-5) disorders, psychiatric history, and socio-demographic characteristics were inferred. Logistic regression analysis was used to determine the factors associated with hospitalization decision upon crisis intervention at discharge. Following crisis intervention at the short-stay unit, 100 patients (39.2%) required further hospitalization and were transferred. Statistically significant factors associated with a higher probability of hospitalization (P<0.05) included the patient's initial wish to be hospitalized (OR=4.28), the presence of a comorbid disorder (OR=3.43), a referral by family or friends (OR=2.89), a history of psychiatric hospitalization (OR=2.71) and suicidal ideation on arrival in the emergency room (OR=2.26). Conversely, significant factors associated with a lower probability of

  15. Present state of electric power business in United States and Europe

    International Nuclear Information System (INIS)

    Onishi, Kenichi

    2011-01-01

    This article reported present state of nuclear power and electric power business in United States and Europe after Fukushima Daiichi Accident. As for the trend of demand and supply of electric power and policy, the accident forced Germany possibly to proceed with phase-out of nuclear power, but France and United States to sustain nuclear power with no great change of energy policy at this moment. As for the trend of electric power market, there was not state in United States with liberalized retail market of electric power after rolling blackouts occurred in California State in the early 2000s. In Germany proceeding with renewable energy introduction, renewable electricity fed into the grid was paid for by the network operators at fixed tariffs and the costs passed on to electricity consumers were increasing. Renewable Portfolio Standards (RPS) in United States forced the state to introduction of renewable energy to some ratio, and Feed-in Tariff (FIT) introduced in EU in 1990s lead to introduction of a large amount of renewable electricity targeted in 2020. Huge amount of wind power introduction brought about several problems to solve such that excess electric power above domestic demand had bad effects on grids in neighboring region. Enforcement of power transmission lines was also needed with increase of maximum electric power as well as introduction of a large amount of renewable electricity. (T. Tanaka)

  16. On generalization of electric field strength in longitudinally blown arcs

    OpenAIRE

    Yas'ko, O.I.; Esipchuk, A.M.; Qing, Z.; Schram, D.C.; Fauchais, P.

    1997-01-01

    Generalization of av. elec. field strength for different discharge conditions in longitudinally blown arcs is considered. Exptl. data for distinctive devices and different gases were used for phys. modeling. Anal. showed that heat transfer processes are responsible for I-E characteristic formation. Turbulent heat transfer is the most effective for atm. pressure discharges while convection plays the main role in vacuum arcs. A generalized I-E characteristic was obtained. [on SciFinder (R)

  17. Straight and chopped DC performance data for a General Electric 5BY436A1 DC shunt motor with a General Electric EV-1 controller

    Science.gov (United States)

    Edie, P. C.

    1981-01-01

    Both straight and chopped dc motor performance data for a General Electric 5BY436A1 motor with a General Electric EV-1 controller is presented in tabular and graphical formats. Effects of motor temperature and operating voltage are also shown. The maximum motor efficiency is approximately 85% at low operating temperatures in the straight dc mode. Chopper efficiency can be assumed to be 95% under all operating conditions. For equal speeds, the motor operated in the chopped mode develops slightly more torque and draws more current than it does in the straight mode.

  18. The impact of electricity price changes on industrial prices and the general price level in Korea

    International Nuclear Information System (INIS)

    Lim, Seul-Ye; Yoo, Seung-Hoon

    2013-01-01

    Electricity has played an important role in the economic development of Korea and, thus, has become a critical factor in sustaining the well-being of the Korean people. This study attempts to investigate the impact of electricity price changes on industrial prices and the general price level using input–output (I–O) analysis. To this end, we apply the I–O price model to the 2011 I–O table recently produced by the Bank of Korea, paying particular attention to the electricity sector by considering it as exogenous and then investigating its impacts. The impacts of the electricity price changes on each industrial sector's prices and the general price level are quantitatively derived. For example, the overall impact of a 10% increase in electricity price on the Korean national economy is estimated to be 0.4367%. We also report the results from the model with the electricity sector endogenous and the model with endogenous electricity and labor sectors. This information can be usefully utilized in decision-making regarding price management for electricity. - Highlights: • We investigate the impact of electricity price changes on the Korean economy. • We use the input–output (I–O) analysis specifying the electricity sector as exogenous. • We apply the I–O price model to 2010 I–O table produced by the Bank of Korea. • The impact of a 10% increase in electricity price on the Korean economy is 0.2176%

  19. Halbach array motor/generators: A novel generalized electric machine

    Energy Technology Data Exchange (ETDEWEB)

    Merritt, B.T.; Post, R.F.; Dreifuerst, G.R.; Bender, D.A. [Lawrence Livermore National Lab., CA (United States)

    1995-02-01

    For many years Klaus Halbach has been investigating novel designs for permanent magnet arrays, using advanced analytical approaches and employing a keen insight into such systems. One of his motivations for this research was to find more efficient means for the utilization of permanent magnets for use in particle accelerators and in the control of particle beams. As a result of his pioneering work, high power free-electron laser systems, such as the ones built at the Lawrence Livermore Laboratory, became feasible, and his arrays have been incorporated into other particle-focusing systems of various types. This paper reports another, quite different, application of Klaus` work, in the design of high power, high efficiency, electric generators and motors. When tested, these motor/generator systems display some rather remarkable properties. Their success derives from the special properties which these arrays, which the authors choose to call {open_quotes}Halbach arrays,{close_quotes} possess.

  20. The quality of operative notes at a general surgery unit.

    Science.gov (United States)

    Rogers, A; Bunting, M; Atherstone, A

    2008-09-01

    With the increasingly litigious nature of medical practice, accurate documentation is critical. This is particularly true for operative procedures, and medical councils have identified this and published guidelines to aid surgeons. However, these remain a frequently cited weakness in their defence in medico-legal cases. This study assessed the accuracy of operative notes in a general surgery unit in order to improve our practice. An audit of 100 consecutive operative notes was performed, and notes were assessed using the Royal College of Surgeons guidelines. The quality of note-taking of trainees was compared with that of consultant surgeons. A series of operation note pro formas was designed in response to the findings. Of the notes, 66% were completed by trainees. The vast majority of notes had no diagram to demonstrate the surgical findings or illustrate the actions. Specialist surgeons were more likely to describe the actions accurately, but less likely to describe wound closure methods or dressings used. They were also less likely to complete adequate postoperative orders. This study identifies key areas of weakness in our operative note-keeping. Pro formas should be introduced and made available for commonly performed procedures, and diagrams should be used wherever possible.

  1. Electric power industry deregulation in the United States: impacts on U.S. and Canadian markets

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G.R. [Putnam, Hayes and Bartlett, Inc., Cambridge, MA (United States)

    1996-10-01

    An overview of the restructuring and deregulation of the United States electric power industry and the implications for the North American natural gas industry was presented. Electric power restructuring and its effect on wholesale and retail competition was discussed. It was suggested that although in the short term electric power deregulation impacts negatively on the natural gas industry, the long term impacts are favourable. The short term impact on the natural gas industry will mean increased competition and downward pressure on gas prices. In contrast, the long term impact could mean increased reliance on gas for electric power generation and convergence of the electric power and natural gas industries.

  2. Highway vehicle electric drive in the United States : 2009 status and issues.

    Energy Technology Data Exchange (ETDEWEB)

    Santini, D. J.; Energy Systems

    2011-02-16

    The status of electric drive technology in the United States as of early 2010 is documented. Rapidly evolving electric drive technologies discussed include hybrid electric vehicles, multiple types of plug-in hybrid electric vehicles, and battery electric vehicles. Recent trends for hybrids are quantified. Various plug-in vehicles entering the market in the near term are examined. The technical and economic requirements for electric drive to more broadly succeed in a wider range of highway vehicle applications are described, and implications for the most promising new markets are provided. Federal and selected state government policy measures promoting and preparing for electric drive are discussed. Taking these into account, judgment on areas where increased Clean Cities funds might be most productively focused over the next five years are provided. In closing, the request by Clean Cities for opinion on the broad range of research needs providing near-term support to electric drive is fulfilled.

  3. Energy from sugarcane bagasse under electricity rationing in Brazil: a computable general equilibrium model

    International Nuclear Information System (INIS)

    Scaramucci, Jose A.; Perin, Clovis; Pulino, Petronio; Bordoni, Orlando F.J.G.; Cunha, Marcelo P. da; Cortez, Luis A.B.

    2006-01-01

    In the midst of the institutional reforms of the Brazilian electric sectors initiated in the 1990s, a serious electricity shortage crisis developed in 2001. As an alternative to blackout, the government instituted an emergency plan aimed at reducing electricity consumption. From June 2001 to February 2002, Brazilians were compelled to curtail electricity use by 20%. Since the late 1990s, but especially after the electricity crisis, energy policy in Brazil has been directed towards increasing thermoelectricity supply and promoting further gains in energy conservation. Two main issues are addressed here. Firstly, we estimate the economic impacts of constraining the supply of electric energy in Brazil. Secondly, we investigate the possible penetration of electricity generated from sugarcane bagasse. A computable general equilibrium (CGE) model is used. The traditional sector of electricity and the remainder of the economy are characterized by a stylized top-down representation as nested CES (constant elasticity of substitution) production functions. The electricity production from sugarcane bagasse is described through a bottom-up activity analysis, with a detailed representation of the required inputs based on engineering studies. The model constructed is used to study the effects of the electricity shortage in the preexisting sector through prices, production and income changes. It is shown that installing capacity to generate electricity surpluses by the sugarcane agroindustrial system could ease the economic impacts of an electric energy shortage crisis on the gross domestic product (GDP)

  4. Manufacturing cost analysis of a parabolic dish concentrator (General Electric design) for solar thermal electric power systems in selected production volumes

    Science.gov (United States)

    1981-01-01

    The manufacturing cost of a General Electric 12 meter diameter concentrator was estimated. This parabolic dish concentrator for solar thermal system was costed in annual production volumes of 100 - 1,000 - 5,000 - 10,000 - 50,000 100,000 - 400,000 and 1,000,000 units. Presented for each volume are the costs of direct labor, material, burden, tooling, capital equipment and buildings. Also presented is the direct labor personnel and factory space requirements. All costs are based on early 1981 economics.

  5. 78 FR 53483 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3

    Science.gov (United States)

    2013-08-29

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00025; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria (ITAAC) completion...

  6. 78 FR 53484 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 4

    Science.gov (United States)

    2013-08-29

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00026; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 4 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria (ITAAC) completion...

  7. 78 FR 65007 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3

    Science.gov (United States)

    2013-10-30

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00026; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion...

  8. Variable structure unit vector control of electric power generation ...

    African Journals Online (AJOL)

    A variable structure Automatic Generation Control (VSAGC) scheme is proposed in this paper for the control of a single area power system model dominated by steam powered electric generating plants. Unlike existing, VSAGC scheme where the selection of the control function is based on a trial and error procedure, the ...

  9. Smart electric grids in the United Kingdom energy strategy

    International Nuclear Information System (INIS)

    Gloaguen, Olivier; Dreyfus, Charles-Antoine

    2011-09-01

    This study first gives an overview of the current status and limitations of the British power grid. It indicates the British energy mix, describes the network structure and its economic operation (gross and retail market with the bid and offer system, role of the System Operator, ways to increase the electricity production). It presents the energy policy and its regulation framework, outlines the current limitations and challenges (ageing grid, power crunch, de-carbonation challenges). It presents the development of a smart grid as a solution to economy de-carbonation challenges: definition of the 'smart grid concept', smart grid development planning (from 2010 to 2050), technological transition associated with smart electric grid development (a cleaner but more intermittent and random electricity production, better use of fossil fuels, electric energy storage, consequences for the grid, introduction and effects of smart meters). It describes the new associated economic model: evolution of the value chain, financial challenges (required investments, expected benefits, subsidies), new regulation system. It addresses the strategic challenges and the various uncertainties (notably in terms of consumption, privacy issue in relation with the use of smart meters, and project implementation).

  10. Regulation and competition in United Kingdom electricity and gas industries

    International Nuclear Information System (INIS)

    McGowan, F.

    1992-01-01

    Focussing on the role of regulation in developing competition, this paper reviews the development of a regulation system to monitor and control prices, as well as, quality of service, in the UK's recently privatized electricity and gas industries. The review covers: the control mechanisms applied to the natural gas tariff and contract markets in the area of common carriage; performance monitoring and the concept of yardstick competition in the electric power industry; and the management and control, by OFFER (Office of Electricity Regulation), of the total 'pool' of generated electricity. It is noted that whereas Great Britain's particular energy supply situation permits this nation to attempt privatization/competition regulation, the energy balances of other European countries make similar attempts, for them, risky. The UK experience with privatization/competition regulation so far has shown that regulation is indispensable in guaranteeing competition, and that the incorporation of the controlling board within the framework of anti-trust legislation and the granting of full autonomy to this board has greatly favoured its effectiveness

  11. Impacts of rising air temperatures on electric transmission ampacity and peak electricity load in the United States

    Science.gov (United States)

    Bartos, Matthew; Chester, Mikhail; Johnson, Nathan; Gorman, Brandon; Eisenberg, Daniel; Linkov, Igor; Bates, Matthew

    2016-11-01

    Climate change may constrain future electricity supply adequacy by reducing electric transmission capacity and increasing electricity demand. The carrying capacity of electric power cables decreases as ambient air temperatures rise; similarly, during the summer peak period, electricity loads typically increase with hotter air temperatures due to increased air conditioning usage. As atmospheric carbon concentrations increase, higher ambient air temperatures may strain power infrastructure by simultaneously reducing transmission capacity and increasing peak electricity load. We estimate the impacts of rising ambient air temperatures on electric transmission ampacity and peak per-capita electricity load for 121 planning areas in the United States using downscaled global climate model projections. Together, these planning areas account for roughly 80% of current peak summertime load. We estimate climate-attributable capacity reductions to transmission lines by constructing thermal models of representative conductors, then forcing these models with future temperature projections to determine the percent change in rated ampacity. Next, we assess the impact of climate change on electricity load by using historical relationships between ambient temperature and utility-scale summertime peak load to estimate the extent to which climate change will incur additional peak load increases. We find that by mid-century (2040-2060), increases in ambient air temperature may reduce average summertime transmission capacity by 1.9%-5.8% relative to the 1990-2010 reference period. At the same time, peak per-capita summertime loads may rise by 4.2%-15% on average due to increases in ambient air temperature. In the absence of energy efficiency gains, demand-side management programs and transmission infrastructure upgrades, these load increases have the potential to upset current assumptions about future electricity supply adequacy.

  12. Electric power supply and demand 1979 to 1988 for the contiguous United States as projected by the Regional Electric Reliability Councils in their April 1, 1979 long-range coordinated planning reports to the Department of Energy

    Energy Technology Data Exchange (ETDEWEB)

    Savage, N.; Graban, W.

    1979-12-01

    Information concerning bulk electric power supply and demand is summarized and reviewed. Electric-utility power-supply systems are composed of power sources, transmission and distribution facilities, and users of electricity. In the United States there are three such systems of large geographic extent that together cover the entire country. Subjects covered are: energy forecasts, peak demand forecasts, generating-capacity forecasts, purchases and sales of capacity, and transmission. Extensive data are compiled in 17 tables. Information in two appendices includes a general description of the Regional Electric Reliability Councils and US generating capacity as of June 30, 1979. 3 figures, 17 tables.

  13. The Issue of Unit Constraints and the Non-Confiscatory Electricity Market

    DEFF Research Database (Denmark)

    Haji Bashi, Mazaher; Rahmati, Iman; Bak, Claus Leth

    2017-01-01

    Security constraint unit commitment is devised to drive the generation unit schedule in a deregulated environment. Generation bids, transmission system constraints and generation unit constraints are thoroughly considered in this optimization problem. It is acceptable that the transmission system...... normal condition constraints may affect the economic opportunities of the generation companies in the electricity market. Transmission system limitations are the inherent limits of the market environment but this is not true for the generation unit constraints. It means that the generation unit...... constraint of a certain player should not affect the economic opportunities of the rivals. If this happen, generation units can claim to the electricity market regulatory board. In this paper the effect of generation unit constraint on the market outcome is discussed. A fair mechanism is introduced in which...

  14. Basic guidelines to introduce electric circuit simulation software in a general physics course

    Science.gov (United States)

    Moya, A. A.

    2018-05-01

    The introduction of electric circuit simulation software for undergraduate students in a general physics course is proposed in order to contribute to the constructive learning of electric circuit theory. This work focuses on the lab exercises based on dc, transient and ac analysis in electric circuits found in introductory physics courses, and shows how students can use the simulation software to do simple activities associated with a lab exercise itself and with related topics. By introducing electric circuit simulation programs in a general physics course as a brief activitiy complementing lab exercise, students develop basic skills in using simulation software, improve their knowledge on the topology of electric circuits and perceive that the technology contributes to their learning, all without reducing the time spent on the actual content of the course.

  15. Feasibility of free piston generation unit for electrical power provision

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, R.; Roskilly, A.; Shaw, R.; French, C. [Newcastle Univ. (United Kingdom)

    2000-07-01

    Free piston linear engines offer the capability of providing power without the need to convert reciprocating motion into rotary motion. This allows for the utilisation of higher peak pressures during the combustion process and thus improves efficiency. The objective of this paper is to outline the potential benefits of a Free Piston Generator (FPG) and discuss the feasibility of this technology as a potential platform for electrical power provision. (authors)

  16. Electric heating of a unit for uranium trioxide production

    International Nuclear Information System (INIS)

    Faron, R.; Striff, A.

    1985-01-01

    Ammonium diuranate U 2 O 7 (NH 4 ) 2 containing about 50% of water is dried and transformed by calcination in uranium trioxide UO 3 . Drying and calcination was obtained by air heated by two burners using domestic fuel. In 1984 the plant was transformed for utilization of electric heating improving maintenance cost, decreasing heat losses and by energy saving the payback period on investment is of 2.6 years [fr

  17. Regulation of unbalanced electromagnetic moment in mutual loading systems of electric machines of traction rolling stock and multiple unit of mainline and industrial transport

    Directory of Open Access Journals (Sweden)

    A. M. Afanasov

    2014-12-01

    Full Text Available Purpose. The research data are aimed to identify the regulatory principles of unbalanced electromagnetic moment of mutually loaded electric machines of traction rolling stock and multiple unit of main and industrial transport. The purpose of this study is energy efficiency increase of the testing of traction electric machines of direct and pulse current using the improvement methods of their mutual loading, including the principles of automatic regulation of mutual loading system. Methodology. The general theoretical provisions and principles of system approach to the theoretical electric engineering, the theory of electric machines and theoretical mechanics are the methodological basis of this research. The known methods of analysis of electromagnetic and electromechanical processes in electrical machines of direct and pulse current are used in the study. Methods analysis of loading modes regulation of traction electric machines was conducted using the generalized scheme of mutual loading. It is universal for all known methods to cover the losses of idling using the electric power. Findings. The general management principles of mutual loading modes of the traction electric machines of direct and pulse current by regulating their unbalanced electric magnetic moment were developed. Regulatory options of unbalanced electromagnetic moment are examined by changing the difference of the magnetic fluxes of mutually loaded electric machines, the current difference of electric machines anchors, the difference of the angular velocities of electric machines shafts. Originality. It was obtained the scientific basis development to improve the energy efficiency test methods of traction electric machines of direct and pulse current. The management principles of mutual loading modes of traction electric machines were formulated. For the first time it is introduced the concept and developed the principles of regulation of unbalanced electromagnetic moment in

  18. Unit: Electric Circuits, Inspection Pack, National Trial Print.

    Science.gov (United States)

    Australian Science Education Project, Toorak, Victoria.

    As a part of the unit materials in the series produced by the Australian Science Education Project, this teacher edition is primarily composed of a core relating to simple circuits, a test form, and options. Options are given under the headings: Your Invention; "How Long Does a Call Last?"; One, Two, Three Wires; Parallel Circuits; More…

  19. Dedicated auxiliary power units for Hybrid Electric Vehicles

    NARCIS (Netherlands)

    Mourad, S.; Weijer, C.J.T. van de

    1998-01-01

    The use of a dedicated auxiliary power unit is essential to utilize the potential that hybrid vehicles offer for efficient and ultra-clean transportation. An example of a hybrid project at the TNO Road-Vehicles Research Institute shows the development and the results of a dedicated auxiliary power

  20. Brunswick Steam Electric Plant, Units 1 and 2. Annual operating report for 1976

    International Nuclear Information System (INIS)

    1977-01-01

    Net electrical energy generated by Unit 1 was 30,399 MWH with the generator on line 334.5 hrs. Unit 2 generated 2,481,014 MWH with the generator on line 4,915.53 hrs. Information is presented concerning operations, shutdowns and power reductions, maintenance, power generation, modifications, changes to operational procedures, radiation exposures, and leak rate testing

  1. Geothermal energy in the western United States and Hawaii: Resources and projected electricity generation supplies

    International Nuclear Information System (INIS)

    1991-09-01

    Geothermal energy comes from the internal heat of the Earth, and has been continuously exploited for the production of electricity in the United States since 1960. Currently, geothermal power is one of the ready-to-use baseload electricity generating technologies that is competing in the western United States with fossil fuel, nuclear and hydroelectric generation technologies to provide utilities and their customers with a reliable and economic source of electric power. Furthermore, the development of domestic geothermal resources, as an alternative to fossil fuel combustion technologies, has a number of associated environmental benefits. This report serves two functions. First, it provides a description of geothermal technology and a progress report on the commercial status of geothermal electric power generation. Second, it addresses the question of how much electricity might be competitively produced from the geothermal resource base. 19 figs., 15 tabs

  2. An assessment of the cyber security legislation and its impact on the United States electrical sector

    Science.gov (United States)

    Born, Joshua

    The purpose of this research was to examine the cyber-security posture for the United States' electrical grid, which comprises a major component of critical infrastructure for the country. The United States electrical sector is so vast, that the Department of Homeland Security (DHS) estimates, it contains more than 6,413 power plants (this includes 3,273 traditional electric utilities and 1,738 nonutility power producers) with approximately 1,075 gigawatts of energy produced on a daily basis. A targeted cyber-security attack against the electric grid would likely have catastrophic results and could even serve as a precursor to a physical attack against the United States. A recent report by the consulting firm Black and Veatch found that one of the top five greatest concerns for United States electric utilities is the risk that cybersecurity poses to their industry and yet, only one-third state they are currently prepared to meet the increasingly likely threat. The report goes on to state, "only 32% of electric utilities surveyed had integrated security systems with the proper segmentation, monitoring and redundancies needed for cyber threat protection. Another 48 % said they did not" Recent estimates indicate that a large-scale cyber-attack against this sector could cost the United States economy as much as a trillion dollars within a weeks' time. Legislative efforts in the past have primarily been focused on creating mandates that encourage public and private partnership, which have been not been adopted as quickly as desired. With 85 % of all electric utilities being privately owned, it is key that the public and private sector partner in order to mitigate risks and respond as a cohesive unit in the event of a major attack. Keywords: Cybersecurity, Professor Riddell, cyber security, energy, intelligence, outlook, electrical, compliance, legislation, partnerships, critical infrastructure.

  3. Comparison study on models for calculation of NPP’s levelized unit electricity cost

    International Nuclear Information System (INIS)

    Nuryanti; Mochamad Nasrullah; Suparman

    2014-01-01

    Economic analysis that is generally done through the calculation of Levelized Unit Electricity Cost (LUEC) is crucial to be done prior to any investment decision on the nuclear power plant (NPP) project. There are several models that can be used to calculate LUEC, which are: R&D PT. PLN (Persero) Model, Mini G4ECONS model and Levelized Cost model. This study aimed to perform a comparison between the three models. Comparison technique was done by tracking the similarity used for each model and then given a case of LUEC calculation for SMR NPP 2 x 100 MW using these models. The result showed that the R&D PT. PLN (Persero) Model have a common principle with Mini G4ECONS model, which use Capital Recovery Factor (CRF) to discount the investment cost which eventually become annuity value along the life of plant. LUEC on both models is calculated by dividing the sum of the annual investment cost and the cost for operating NPP with an annual electricity production.While Levelized Cost model based on the annual cash flow. Total of annual costs and annual electricity production were discounted to the first year of construction in order to obtain the total discounted annual cost and the total discounted energy generation. LUEC was obtained by dividing both of the discounted values. LUEC calculations on the three models produce LUEC value, which are: 14.5942 cents US$/kWh for R&D PT. PLN (Persero) Model, 15.056 cents US$/kWh for Mini G4ECONs model and 14.240 cents US$/kWh for Levelized Cost model. (author)

  4. 10 CFR 9.45 - Annual report to the Attorney General of the United States.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Annual report to the Attorney General of the United States... Regulations § 9.45 Annual report to the Attorney General of the United States. (a) On or before February 1 of each year, the NRC will submit a report covering the preceding fiscal year to the Attorney General of...

  5. 38 CFR 1.205 - Notification to the Attorney General or United States Attorney's Office.

    Science.gov (United States)

    2010-07-01

    ... Attorney General or United States Attorney's Office. 1.205 Section 1.205 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS GENERAL PROVISIONS Referrals of Information Regarding Criminal Violations § 1.205 Notification to the Attorney General or United States Attorney's Office. VA police and/or...

  6. Electric utility fuel choice behavior in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Joskow, P.L.; Mishkin, F.S.

    1977-10-01

    Electric utility fuel choice behavior is analyzed by a conditional logit model to determine the effects of changing oil prices of five plants. Three of the plants faced favorable expected coal prices and, like many areas of the country, were insensitive to changing oil prices. This was not the case at the New England plant, however, where relatively small price increases would decrease the likelihood of choosing oil as an alternative fuel for new plants. The modeling of utility behavior in fuel decisions is felt to be applicable to other industries where a continuum of decision possibilities does not reasonably characterize choice alternatives. New behavior models are urged in order to obtain better predictions of the effects of a changing economic environment. 10 references.

  7. General solution for calculating polarization electric fields in the auroral ionosphere and application examples

    Science.gov (United States)

    Amm, O.; Fujii, R.; VanhamäKi, H.; Yoshikawa, A.; Ieda, A.

    2013-05-01

    We devise an approach to calculate the polarization electric field in the ionosphere, when the ionospheric conductances, the primary (modeled) or the total (measured) electric field, and the Cowling efficiency are given. In contrast to previous studies, our approach is a general solution which is not limited to specific geometrical setups, and all parameters may have any kind of spatial dependence. The solution technique is based on spherical elementary current (vector) systems (SECS). This way, we avoid the need to specify explicit boundary conditions for the searched polarization electric field of its potential which would be required if the problem was solved in a differential equation approach. Instead, we solve an algebraic matrix equation, and the implicit boundary condition that the divergence of the polarization electric field vanishes outside our analysis area is sufficient. In order to illustrate our theory, we then apply it to two simple models of auroral electrodynamic situations, the first being a mesoscale strong conductance enhancement in the early morning sector within a relatively weak southward primary electric field, and a morning sector auroral arc with only a weak conductance enhancement, but a large southward primary electric field at the poleward flank of the arc. While the significance of the polarization electric field for maximum Cowling efficiency is large for the first case, it is rather minor for the second one. Both models show that the polarization electric field effect may not only change the magnitude of the current systems but also their overall geometry. Furthermore, the polarization electric field may extend into regions where the primary electric field is small, thus even dominating the total electric field in these regions. For the first model case, the total Joule heating integrated over the analysis area decreases by a factor of about 4 for maximum Cowling efficiency as compared to the case of vanishing Cowling efficiency

  8. High Power Alternator Test Unit (ATU) Electrical System Test

    Science.gov (United States)

    Birchenough, Arthur; Hervol, David

    2007-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was used to simulate the operating conditions and evaluate the performance of the ATU and it s interaction with various LPSF components in accordance with the JIMO AC Power System Requirements. The testing was carried out at the breadboard development level. Results of these tests will be used for the development and validation of analytical models for performance and lifetime prediction.

  9. Perceptions of a disability sport unit in general physical education.

    Science.gov (United States)

    Grenier, Michelle; Collins, Karen; Wright, Steven; Kearns, Catherine

    2014-01-01

    The purpose of this qualitative study was to assess the effectiveness of a disability sport unit in shaping perceptions of disability. Data from interviews, observations, and documents were collected on 87 elementary-aged students, one physical education teacher, and one teaching intern. Comparisons were drawn between fifth graders engaged in a five-week disability sport unit to fourth graders participating in their standard physical education curriculum. Findings revealed differences in the way fourth and fifth graders came to view individuals with disabilities. The results support an analysis of curriculum development that underscores the significance of the social model in positively impacting constructions of disability. Recommendations include the use of disability sports in physical education as an effective strategy for educating students in game play, knowledge of the Paralympics, and the inclusion of individuals with disabilities in a variety of sporting venues.

  10. Generic functional modelling of multi-pulse auto-transformer rectifier units for more-electric aircraft applications

    Directory of Open Access Journals (Sweden)

    Tao YANG

    2018-05-01

    Full Text Available The Auto-Transformer Rectifier Unit (ATRU is one preferred solution for high-power AC/DC power conversion in aircraft. This is mainly due to its simple structure, high reliability and reduced kVA ratings. Indeed, the ATRU has become a preferred AC/DC solution to supply power to the electric environment control system on-board future aircraft. In this paper, a general modelling method for ATRUs is introduced. The developed model is based on the fact that the DC voltage and current are strongly related to the voltage and current vectors at the AC terminals of ATRUs. In this paper, we carry on our research in modelling symmetric 18-pulse ATRUs and develop a generic modelling technique. The developed generic model can study not only symmetric but also asymmetric ATRUs. An 18-pulse asymmetric ATRU is used to demonstrate the accuracy and efficiency of the developed model by comparing with corresponding detailed switching SABER models provided by our industrial partner. The functional models also allow accelerated and accurate simulations and thus enable whole-scale more-electric aircraft electrical power system studies in the future. Keywords: Asymmetric transformer, Functional modelling, More-Electric Aircraft, Multi-pulse rectifier, Transformer rectifier unit

  11. Standard Technical Specifications for General Electric Boiling Water Reactors (BWR/5)

    International Nuclear Information System (INIS)

    Bottimore, R.R.

    1980-12-01

    The Standard Technical Specifications for General Electric Boiling Water Reactors (GE-STS) is a generic document prepared by the US NRC for use in the licensing process of current General Electric Boiling Water Reactors. The GE-STS sets forth the limits, operating conditions, and other requirements applicable to nuclear reactor facility operation as set forth by Section 50.36 of 10 CFR Part 50 for the protection of the health and safety of the public. The document is revised periodically to reflect current licensing requirements

  12. Design and performance of General Electric boiling water reactor main steam line isolation valves

    International Nuclear Information System (INIS)

    Rockwell, D.A.; van Zylstra, E.H.

    1976-08-01

    An extensive test program has been completed by the General Electric Company in cooperation with the Commonwealth Edison Company on the basic design type of large main steam line isolation valves used on General Electric Boiling Water Reactors. Based on a total of 40 tests under simulated accident conditions covering a wide range of mass flows, mixture qualities, and closing times, it was concluded that the commercially available valves of this basic type will close completely and reliably as required. Analytical methods to predict transient effects in the steam line and valve after postulated breaks were refined and confirmed by the test program

  13. Generalized trust and intelligence in the United States.

    Directory of Open Access Journals (Sweden)

    Noah Carl

    Full Text Available Generalized trust refers to trust in other members of society; it may be distinguished from particularized trust, which corresponds to trust in the family and close friends. An extensive empirical literature has established that generalized trust is an important aspect of civic culture. It has been linked to a variety of positive outcomes at the individual level, such as entrepreneurship, volunteering, self-rated health, and happiness. However, two recent studies have found that it is highly correlated with intelligence, which raises the possibility that the other relationships in which it has been implicated may be spurious. Here we replicate the association between intelligence and generalized trust in a large, nationally representative sample of U.S. adults. We also show that, after adjusting for intelligence, generalized trust continues to be strongly associated with both self-rated health and happiness. In the context of substantial variation across countries, these results bolster the view that generalized trust is a valuable social resource, not only for the individual but for the wider society as well.

  14. The United Nations General Assembly and Disarmament 1987

    International Nuclear Information System (INIS)

    1988-01-01

    The report offers a summary of the proposals made and action taken on disarmament issues by the Assembly at its forty-second regular session. It is published in the framework of the World Disarmament Campaign, which was launched by a unanimous decision of the Assembly in 1982 to inform, to educate and to generate public understanding and support for the objectives of the United Nations in the field of disarmament

  15. Comparative energy and exergy performance assessments of a microcogenerator unit in different electricity mix scenarios

    International Nuclear Information System (INIS)

    Gonçalves, Pedro; Angrisani, Giovanni; Roselli, Carlo; Gaspar, Adélio R.; Gameiro da Silva, Manuel

    2013-01-01

    Highlights: • Experimental and energy–exergy modelling of a 6 kW micro-combined heat and power unit. • Evaluation of energy and exergy efficiencies for performance assessment. • Use of exergy and energy indicators for comparison with a reference system. • Use of different renewables supply options into the electric and heat reference system. • The electric grid mix of Portugal and Italy is used and discussed. - Abstract: The Directive 2004/8/EC on the promotion of cogeneration proposes a comparative indicator based on primary energy savings, neglecting some important thermodynamic aspects, such as exergy. This study aims to compare and discuss the usefulness of a set of complementary indicators for performance assessments of cogeneration systems, concerning thermodynamic principles based on first and second law (the exergy approach). As case study, a 6 kW electric output micro-combined heat and power unit was experimentally tested and a model of the unit was developed in TRNSYS. Considering as reference a set of different heat and electricity scenarios, including the actual electric mixes of Portugal and Italy, the indicators case incon (PES) and Primary and Total Irreversibilities Savings (PIS and TIS), as well as energy and exergy renewability ratios were assessed and discussed. The results show that the use of MCHP has higher advantages for the Italian electric grid, than an equivalent scenario considering the Portuguese electric network as reference. As result, for a particular scenario analysed, PES and PIS have 3% and 6% for Portugal, and 10% and 18% for Italy, respectively. Furthermore, for one particular scenario evaluated, the indicators energetic and exergetic renewability ratios have 23% and 14%, respectively for the Portuguese electric grid, and 19% and 10% for the Italian electric system

  16. Wind power development in the United States: Effects of policies and electricity transmission congestion

    Science.gov (United States)

    Hitaj, Claudia

    In this dissertation, I analyze the drivers of wind power development in the United States as well as the relationship between renewable power plant location and transmission congestion and emissions levels. I first examine the role of government renewable energy incentives and access to the electricity grid on investment in wind power plants across counties from 1998-2007. The results indicate that the federal production tax credit, state-level sales tax credit and production incentives play an important role in promoting wind power. In addition, higher wind power penetration levels can be achieved by bringing more parts of the electricity transmission grid under independent system operator regulation. I conclude that state and federal government policies play a significant role in wind power development both by providing financial support and by improving physical and procedural access to the electricity grid. Second, I examine the effect of renewable power plant location on electricity transmission congestion levels and system-wide emissions levels in a theoretical model and a simulation study. A new renewable plant takes the effect of congestion on its own output into account, but ignores the effect of its marginal contribution to congestion on output from existing plants, which results in curtailment of renewable power. Though pricing congestion removes the externality and reduces curtailment, I find that in the absence of a price on emissions, pricing congestion may in some cases actually increase system-wide emissions. The final part of my dissertation deals with an econometric issue that emerged from the empirical analysis of the drivers of wind power. I study the effect of the degree of censoring on random-effects Tobit estimates in finite sample with a particular focus on severe censoring, when the percentage of uncensored observations reaches 1 to 5 percent. The results show that the Tobit model performs well even at 5 percent uncensored observations

  17. Results from the Operational Testing of the General Electric Smart Grid Capable Electric Vehicle Supply Equipment (EVSE)

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Richard Barney [Idaho National Lab. (INL), Idaho Falls, ID (United States); Scoffield, Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bennett, Brion [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-12-01

    The Idaho National Laboratory conducted testing and analysis of the General Electric (GE) smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from GE for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the GE smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

  18. Commerical electric power cost studies. Capital cost addendum multi-unit coal and nuclear stations

    International Nuclear Information System (INIS)

    1977-09-01

    This report is the culmination of a study performed to develop designs and associated capital cost estimates for multi-unit nuclear and coal commercial electric power stations, and to determine the distribution of these costs among the individual units. This report addresses six different types of 2400 MWe (nominal) multi-unit stations as follows: Two Unit PWR Station-1139 MWe Each, Two Unit BWR Station-1190 MWe Each, Two Unit High Sulfur Coal-Fired Station-1232 MWe Each, Two Unit Low Sulfur Coal-Fired Station-1243 MWe Each, Three Unit High Sulfur Coal-Fired Station-794 MWe Each, Three Unit Low Sulfur Coal-Fired Station-801 MWe Each. Recent capital cost studies performed for ERDA/NRC of single unit nuclear and coal stations are used as the basis for developing the designs and costs of the multi-unit stations. This report includes the major study groundrules, a summary of single and multi-unit stations total base cost estimates, details of cost estimates at the three digit account level and plot plan drawings for each multi-unit station identified

  19. Comparative study of radiation dose between digital panoramic X-ray unit and general panoramic X-ray unit

    International Nuclear Information System (INIS)

    Li Qingshan; Duan Tao; Wang Xiaoyun; Zhao Li; Dong Jian; Wei Lei

    2010-01-01

    Objective: To compare the actual dose of patients who receive the same medical practice by either digital panoramic X-ray unit and general panoramic X-ray unit and give evidence for better selection of oral X-ray examination method. Methods: Round sheet lithium fluoride (LiF) thermoluminescent dosimeters (TLD) were used. The experiment was divided into natural background contrast group, general panoramic X-ray children group, general panoramic X-ray adults group, digital panoramic X-ray children group and digital panoramic X-ray adults group. The dosimeter of natural background radiation was placed at the office of the doctor, the dosimeters of general panoramic X-ray children group and general panoramic X-ray adults group were irradiated by different conditions according to the clinical application of panoramic X-ray to children and adults, the dosimeters of digital panoramic X-ray children group and digital panoramic X-ray adults group were irradiated by different conditions according to the clinical application of digital panoramic X-ray to children and adults. The thermoluminescent dosimeter was used to count and calculate the exposure doses in various groups. Results: The dose of children exposed in general panoramic X-ray unit was 1.28 times of that in digital panoramic X-ray unit, there was significant difference (t=6.904, P<0.01). The dose of adults exposed in general panoramic X-ray unit was 1.55 times of that in the digital panoramic X-ray unit, there also was significant difference (t=-11.514. P< 0.01). Conclusion: The digital panoramic X-ray unit can reduce the dose of patients, so the digital panoramic X-ray unit should be used as far as possible. (authors)

  20. Electricity

    International Nuclear Information System (INIS)

    Tombs, F.

    1983-01-01

    The subject is discussed, with particular reference to the electricity industry in the United Kingdom, under the headings; importance and scope of the industry's work; future fuel supplies (estimated indigenous fossil fuels reserves); outlook for UK energy supplies; problems of future generating capacity and fuel mix (energy policy; construction programme; economics and pricing; contribution of nuclear power - thermal and fast reactors; problems of conversion of oil-burning to coal-burning plant). (U.K.)

  1. Statement to the 54th session of the United Nations General Assembly. United Nations, New York, 4 November 1999

    International Nuclear Information System (INIS)

    ElBaradei, M.

    1999-01-01

    In his Statement to the 54th Session of the United Nations General Assembly (New York, 4 November 1999), the Director General of the IAEA presented some of the major Agency's achievements in fulfilling its mandate as described in the Annual Report of the IAEA for 1998, and also some of the challenges and opportunities that lie ahead

  2. General method for calculating polarization electric fields produced by auroral Cowling mechanism and application examples

    Science.gov (United States)

    Vanhamäki, Heikki; Amm, Olaf; Fujii, Ryo; Yoshikawa, Aki; Ieda, Aki

    2013-04-01

    The Cowling mechanism is characterized by the generation of polarization space charges in the ionosphere in consequence of a partial or total blockage of FAC flowing between the ionosphere and the magnetosphere. Thus a secondary polarization electric field builds up in the ionosphere, which guarantees that the whole (primary + secondary) ionospheric current system is again in balance with the FAC. In the Earth's ionosphere the Cowling mechanism is long known to operate in the equatorial electrojet, and several studies indicate that it is important also in auroral current systems. We present a general method for calculate the secondary polarization electric field, when the ionospheric conductances, the primary (modeled) or the total (measured) electric field, and the Cowling efficiency are given. Here the Cowling efficiency is defined as the fraction of the divergent Hall current canceled by secondary Pedersen current. In contrast to previous studies, our approach is a general solution which is not limited to specific geometrical setups (like an auroral arc), and all parameters may have any kind of spatial dependence. The solution technique is based on spherical elementary current (vector) systems (SECS). This way, we avoid the need to specify explicit boundary conditions for the searched polarization electric field or its potential, which would be required if the problem was solved in a differential equation approach. Instead, we solve an algebraic matrix equation, for which the implicit boundary condition that the divergence of the polarization electric field vanishes outside our analysis area is sufficient. In order to illustrate the effect of Cowling mechanism on ionospheric current systems, we apply our method to two simple models of auroral electrodynamic situations: 1) a mesoscale strong conductance enhancement in the early morning sector within a relatively weak southward primary electric field, 2) a morning sector auroral arc with only a weak conductance

  3. Magnetohydrodynamic flow of generalized Maxwell fluids in a rectangular micropump under an AC electric field

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Guangpu [School of Mathematical Science, Inner Mongolia University, Hohhot, Inner Mongolia 010021 (China); Jian, Yongjun, E-mail: jianyj@imu.edu.cn [School of Mathematical Science, Inner Mongolia University, Hohhot, Inner Mongolia 010021 (China); Chang, Long [School of Mathematics and Statistics, Inner Mongolia University of Finance and Economics, Hohhot, Inner Mongolia 010051 (China); Buren, Mandula [School of Mathematical Science, Inner Mongolia University, Hohhot, Inner Mongolia 010021 (China)

    2015-08-01

    By using the method of separation of variables, an analytical solution for the magnetohydrodynamic (MHD) flow of the generalized Maxwell fluids under AC electric field through a two-dimensional rectangular micropump is reduced. By the numerical computation, the variations of velocity profiles with the electrical oscillating Reynolds number Re, the Hartmann number Ha, the dimensionless relaxation time De are studied graphically. Further, the comparison with available experimental data and relevant researches is presented. - Highlights: • MHD flow of the generalized Maxwell fluids under AC electric field is analyzed. • The MHD flow is confined to a two-dimensional rectangular micropump. • Analytical solution is obtained by using the method of separation of variables. • The influences of related parameters on the MHD velocity are discussed.

  4. Magnetohydrodynamic flow of generalized Maxwell fluids in a rectangular micropump under an AC electric field

    International Nuclear Information System (INIS)

    Zhao, Guangpu; Jian, Yongjun; Chang, Long; Buren, Mandula

    2015-01-01

    By using the method of separation of variables, an analytical solution for the magnetohydrodynamic (MHD) flow of the generalized Maxwell fluids under AC electric field through a two-dimensional rectangular micropump is reduced. By the numerical computation, the variations of velocity profiles with the electrical oscillating Reynolds number Re, the Hartmann number Ha, the dimensionless relaxation time De are studied graphically. Further, the comparison with available experimental data and relevant researches is presented. - Highlights: • MHD flow of the generalized Maxwell fluids under AC electric field is analyzed. • The MHD flow is confined to a two-dimensional rectangular micropump. • Analytical solution is obtained by using the method of separation of variables. • The influences of related parameters on the MHD velocity are discussed

  5. An analysis of referrals received by a psychiatric unit in a general ...

    African Journals Online (AJOL)

    An analysis of referrals received by a psychiatric unit in a general hospital part 1: the need for and research design adopted to study referrals received by a psychiatric unit in a general hospital: research. M. Dor, V.J. Ehlers, M.M. Van der Merwe ...

  6. 48 CFR 1631.203-71 - Business unit General and Administrative (G&A) expenses.

    Science.gov (United States)

    2010-10-01

    ... Business unit General and Administrative (G&A) expenses. G&A expenses shall be allocated to final cost... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Business unit General and Administrative (G&A) expenses. 1631.203-71 Section 1631.203-71 Federal Acquisition Regulations System OFFICE OF...

  7. Updated Value of Service Reliability Estimates for Electric Utility Customers in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Michael [Nexant Inc., Burlington, MA (United States); Schellenberg, Josh [Nexant Inc., Burlington, MA (United States); Blundell, Marshall [Nexant Inc., Burlington, MA (United States)

    2015-01-01

    This report updates the 2009 meta-analysis that provides estimates of the value of service reliability for electricity customers in the United States (U.S.). The meta-dataset now includes 34 different datasets from surveys fielded by 10 different utility companies between 1989 and 2012. Because these studies used nearly identical interruption cost estimation or willingness-to-pay/accept methods, it was possible to integrate their results into a single meta-dataset describing the value of electric service reliability observed in all of them. Once the datasets from the various studies were combined, a two-part regression model was used to estimate customer damage functions that can be generally applied to calculate customer interruption costs per event by season, time of day, day of week, and geographical regions within the U.S. for industrial, commercial, and residential customers. This report focuses on the backwards stepwise selection process that was used to develop the final revised model for all customer classes. Across customer classes, the revised customer interruption cost model has improved significantly because it incorporates more data and does not include the many extraneous variables that were in the original specification from the 2009 meta-analysis. The backwards stepwise selection process led to a more parsimonious model that only included key variables, while still achieving comparable out-of-sample predictive performance. In turn, users of interruption cost estimation tools such as the Interruption Cost Estimate (ICE) Calculator will have less customer characteristics information to provide and the associated inputs page will be far less cumbersome. The upcoming new version of the ICE Calculator is anticipated to be released in 2015.

  8. General review of diagnostic systems in EDF PWR units

    International Nuclear Information System (INIS)

    Chevalier, R.; Brasseur, S.; Ricard, B.

    1998-01-01

    Since the beginning of the French nuclear program, Electricite de France (EDF) has looked for ways to improve the availability and safety of its nuclear units. Therefore, monitoring systems on turbogenerators, reactor coolant pumps, primary circuits and core internal structures were designed by the Research and Development Division and implemented with technologies available during the 1970's. However, mainly because of difficulties for data interpretation by plant personnel, EDF subsequently decided to design and develop different tools to help plant operators to process a diagnosis: - a new generation of the Monitoring and Diagnostic System called PSAD, - expert systems for diagnosis on reactor coolant pumps (RCP) 'DIAPO' and turbogenerator units (TG) 'DIVA', - diagnostic guides written for most equipment pending the installation of new monitoring and diagnosis systems. The first version of PSAD, installed in five units, performs on-line monitoring of the turbogenerator shaft line, steam inlet valves, the reactor coolant pumps and the generator stator. The second version not yet implemented, will include Loose Part Detection (LPD) and Core Internal Structure Monitoring (CISM). The level of diagnosis achieved by PSAD depends on the component monitored. The TG and RCP monitoring functions of PSAD compute high level diagnosis descriptors such as natural frequencies and long term trends but do not elaborate a diagnosis automatically. However, a diagnostic assistance window is available on-line, whenever a warning message is displayed, whether for immediate or later action. The window presents a diagnostic approach whose purpose is to find the causes of the symptoms observed. This diagnosis approach is automated in the DIVA and DIAPO expert systems. Numerous potential faults can be identified for both systems thanks to a hierarchy of abnormal situations. The user interactively answers questions when information is needed to progress in the diagnosis. The resulting

  9. REDUNDANT ELECTRIC MOTOR DRIVE CONTROL UNIT DESIGN USING AUTOMATA-BASED APPROACH

    Directory of Open Access Journals (Sweden)

    Yuri Yu. Yankin

    2014-11-01

    Full Text Available Implementation of redundant unit for motor drive control based on programmable logic devices is discussed. Continuous redundancy method is used. As compared to segregated standby redundancy and whole system standby redundancy, such method provides preservation of all unit functions in case of redundancy and gives the possibility for continuous monitoring of major and redundant elements. Example of that unit is given. Electric motor drive control channel block diagram contains two control units – the major and redundant; it also contains four power supply units. Control units programming was carried out using automata-based approach. Electric motor drive control channel model was developed; it provides complex simulation of control state-machine and power converter. Through visibility and hierarchy of finite state machines debug time was shortened as compared to traditional programming. Control state-machine description using hardware description language is required for its synthesis with FPGA-devices vendor design software. This description was generated automatically by MATLAB software package. To verify results two prototype control units, two prototype power supply units, and device mock-up were developed and manufactured. Units were installed in the device mock-up. Prototype units were created in accordance with requirements claimed to deliverable hardware. Control channel simulation and tests results in the perfect state and during imitation of major element fault are presented. Automata-based approach made it possible to observe and debug control state-machine transitions during simulation of transient processes, occurring at imitation of faults. Results of this work can be used in development of fault tolerant electric motor drive control channels.

  10. 76 FR 68634 - Airworthiness Directives; General Electric Company (GE) CF6 Turbofan Engines

    Science.gov (United States)

    2011-11-07

    ... Airworthiness Directives; General Electric Company (GE) CF6 Turbofan Engines AGENCY: Federal Aviation... ``(c) This AD applies to * * * and CF6-80A3 turbofan engines with left-hand links * * *.'' to ``(c) This AD applies to * * * and CF6-80A3 turbofan engines, including engines marked on the engine data...

  11. 75 FR 47644 - General Electric Company, Transportation Division, Including On-Site Leased Workers From Adecco...

    Science.gov (United States)

    2010-08-06

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,174] General Electric Company... that was totally or partially separated from employment. It was determined, however, that imports of... Globalization Adjustment Assistance Act of 2009, section 222 of the Act (19 U.S.C. 2272) covers foreign...

  12. Hazardous Waste Cleanup: Caribe General Electric Product in Rio Piedras, Puerto Rico

    Science.gov (United States)

    The Caribe General Electric Product facility (GE Río Piedras) covers approximately 4 acres and is situated on the northern coastal plain in a relatively flat industrial/urban area of Río Piedras with an elevation between 20 and 40 feet above mean sea leve

  13. Marble Hill Nuclear Generating Station, Units 1 and 2. License application, PSAR, general information

    International Nuclear Information System (INIS)

    1975-01-01

    An application is presented for two PWR reactors to be constructed in Salud Township, Jefferson County, Indiana, about six miles northeast of New Washington on the Ohio River. Each unit will have a rated core power level of 3411 MW(t) with a corresponding electrical output of 1130 MW(e). Mechanical draft cooling towers will be provided. The facility, which will replicate the Byron facility will be employed for the generation of electricity for transmission, sale for resale, and distribution

  14. Role of nuclear energy in the establishment of smart electricity networks in the United States

    International Nuclear Information System (INIS)

    Harding, Margaret

    2012-01-01

    The concept that smart grids are separate from, and conflict with, traditional grids has been discussed in recent times. A key fact that has to be understood is that in the current electricity grid of the US, electricity is generated as it is demanded. With the advent of intermittent power suppliers like wind and solar, and changing load curves due to increasing electricity usage (electric cars, more electrical appliances and equipment), the traditional methods of managing the grid are being significantly stressed. There are significant losses of electricity occurring in the current US transmission and distribution system as well as inflexibility for transmission of electricity across long distance required to use intermittent sources that are generally more available in the west at major population and industrial centers in the east. Smart grid is really about improving the reliability of the overall electricity supply. This entails managing supply as well as demand, but most importantly, the transmission and distribution of electricity. Nuclear energy tends to be used as base load supply. The reasons for this are primarily economic, though technology does play a role. The economic reasons center around the fact that nuclear is a capital intensive energy source. Nuclear and solar can work together in some interesting and more optimal ways. Because solar is tied to hours of daylight and tends to peak at midday when demand is starting to rise to peak as well, nuclear and solar can work as base load and peak demand response effectively.

  15. An examination of electricity generation by utility organizations in the Southeast United States

    International Nuclear Information System (INIS)

    Craig, Christopher A.; Feng, Song

    2016-01-01

    This study examined the impact of climatic variability on electricity generation in the Southeast United States. The relationship cooling degree days (CDD) and heating degree days (HDD) shared with electricity generation by fuel source was explored. Using seasonal autoregressive integrated weighted average (ARIMA) and seasonal simple exponentially smoothed models, retrospective time series analysis was run. The hypothesized relationship between climatic variability and total electricity generation was supported, where an ARIMA model including CDDs as a predictor explained 57.6% of the variability. The hypothesis that climatic variability would be more predictive of fossil fuel electricity generation than electricity produced by clean energy sources was partially supported. The ARIMA model for natural gas indicated that CDDS were the only predictor for the fossil fuel source, and that 79.4% of the variability was explained. Climatic variability was not predictive of electricity generation from coal or petroleum, where simple seasonal exponentially smoothed models emerged. However, HDDs were a positive predictor of hydroelectric electricity production, where 48.9% of the variability in the clean energy source was explained by an ARIMA model. Implications related to base load electricity from fossil fuels, and future electricity generation projections relative to extremes and climate change are discussed. - Highlights: • Models run to examine impact of climatic variability on electricity generation. • Cooling degree days explained 57.6% of variability in total electricity generation. • Climatic variability was not predictive of coal or petroleum generation. • Cooling degree days explained 79.4% of natural gas generation. • Heating degree days were predictive of nuclear and hydroelectric generation.

  16. Uncited Research Articles in Popular United States General Radiology Journals.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Chung, Ryan; Duszak, Richard

    2018-05-03

    This study aimed to characterize articles in popular general radiology journals that go uncited for a decade after publication. Using the Web of Science database, we identified annual citation counts for 13,459 articles published in Radiology, American Journal of Roentgenology, and Academic Radiology between 1997 and 2006. From this article cohort, we then identified all original research articles that accrued zero citations within a decade of publication. A concurrent equal-sized cohort of most cited articles was created. Numerous characteristics of the uncited and most cited articles were identified and compared. Only 47 uncited articles went uncited for a decade after publication. When compared to the 47 most cited articles over that same window, the uncited articles were significantly (P articles, uncited articles also had significantly (P articles published in popular general radiology journals, only a very small number of original research investigations remained uncited a decade after publication. Given that citations reflect the impact of radiology research, this observation suggests that journals are appropriately selecting meaningful work. Investigators seeking to avoid futile publication might consider their research initiatives in light of these characteristics. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  17. Heavy metal multilayers for switching of magnetic unit via electrical current without magnetic field, method and applications

    Science.gov (United States)

    Ma, Qinli; Li, Yufan; Chien, Chia-ling

    2018-02-20

    Provided is an electric-current-controllable magnetic unit, including: a substrate, an electric-current channel disposed on the substrate, the electric-current channel including a composite heavy-metal multilayer comprising at least one heavy-metal; a capping layer disposed over the electric-current channel; and at least one ferromagnetic layer disposed between the electric-current channel and the capping layer.

  18. The challenges of a good use of electricity: China, United States, India and the European Union

    International Nuclear Information System (INIS)

    Dessus, B.; Laponche, B.

    2011-01-01

    After a discussion of the peculiar characteristics of electricity as energy vector (electricity production, transport and distribution, usages, the issue of load curves and power), this report identifies and discusses criteria corresponding to a 'good use' of electricity. These criteria are related to several issues: greenhouse gas emissions, availability and costs of natural resources, safety, local and global environment, economical and social issues. These issues are addressed through the examination of electricity consumption in China and India, of its evolution in comparison with two other regions (United States and Europe). A third part discusses opportunities and perspectives of a good use of electricity in China and India, in the main socio-economic sectors, and their consequences for the environment, for the preservation of natural resources, and for the Indian and Chinese economy. These aspects are also addressed in comparison with the United States and Europe. Thus, the authors highlight the contrast between the electricity consumption curves for some sectors depending on strategic choices by the Chinese and Indian governments

  19. Electric Motors. An Instructional Unit for High School Teachers of Vocational Agriculture.

    Science.gov (United States)

    Dalton, Delmer; Carpenter, Bruce

    Designed as a 3-week course of study in the agricultural mechanics curriculum to be taught at the junior or senior high school level, this unit on electric motors is divided into 11 major performance objectives. Each objective is subdivided into the areas of content, suggested teaching and learning activities, resources, and evaluation. Topics for…

  20. 75 FR 8753 - Carolina Power & Light Company, Brunswick Steam Electric Plant, Units 1 and 2; Environmental...

    Science.gov (United States)

    2010-02-25

    ... Dusenbury of the North Carolina Department of Environment and Natural Resources regarding the environmental... & Light Company, Brunswick Steam Electric Plant, Units 1 and 2; Environmental Assessment and Finding of No... identification of licensing and regulatory actions requiring environmental assessments,'' the NRC prepared an...

  1. Miniaturized Power Processing Unit Study: A Cubesat Electric Propulsion Technology Enabler Project

    Science.gov (United States)

    Ghassemieh, Shakib M.

    2014-01-01

    This study evaluates High Voltage Power Processing Unit (PPU) technology and driving requirements necessary to enable the Microfluidic Electric Propulsion technology research and development by NASA and university partners. This study provides an overview of the state of the art PPU technology with recommendations for technology demonstration projects and missions for NASA to pursue.

  2. Motor unit activation order during electrically evoked contractions of paralyzed or partially paralyzed muscles

    NARCIS (Netherlands)

    Thomas, CK; Nelson, G; Than, L; Zijdewind, Inge

    The activation order of motor units during electrically evoked contractions of paralyzed or partially paralyzed thenar muscles was determined in seven subjects with chronic cervical spinal cord injury. The median nerve was stimulated percutaneously with pulses of graded intensity to produce

  3. EQUATIONS OF ELECTRIC MOTOR POWER SUPPLY UNIT DISSYMMETRY UNDER PHASE SHORT-CIRCUIT FAULT

    Directory of Open Access Journals (Sweden)

    V.Y. Tchaban

    2013-04-01

    Full Text Available In the paper, a formula is introduced for calculating electric motor supply unit voltage under feeding by a common transformer in the condition of a phase short-circuit in one of the motors. The formula is used in every time step of electromechanical state equations integration.

  4. Electric strength of metal-ceramic brazed units of thermionic energy converters in cesium vapours

    International Nuclear Information System (INIS)

    Belousenko, A.P.; Vasilchenko, A.V.; Nikolaev, Y.V.

    1989-01-01

    The investigation of electric strength characteristics of the hollow metal-ceramic brazed units of thermionic energy converters with the insulator 1 = 10-50 mm from polycrystal aluminum oxide at the temperature T = 450-750 degrees and the cesium vapour pressure P Cs = 10 - 1 -10 3 Pa has been carried out. The experimental dependencies of the break-down voltage of the brazed units on the temperature, parameter P Cs · 1 and the value of surface electric resistance of the insulators are given as well as the empiric equations obtained with the help of experimental data for calculating the break-down voltage. A mechanism of ceramic insulator influence on electric strength characteristics of the cesium gap is investigated. A breakdown model explaining this influence is proposed

  5. Liberalisation of the electricity sector and development of distributed generation: Germany, United Kingdom and France

    International Nuclear Information System (INIS)

    Menanteau, Ph.

    2003-01-01

    Historically, electricity systems have been made up of small local networks gradually becoming incorporated to benefit from the diversity of demand and the economies of scale in electricity generation that are possible with large interconnected systems. Today, this logic would seem to have certain limits, now that the benefits related to the size of production units appear to have been exhausted and in view of the growing difficulties in developing new transmission infrastructures. At the same time, there have been considerable improvements in the technical and economic performance of modular generating techniques, which are now enjoying significant development under the effect of electricity sector liberalization and policies to reduce greenhouse gas emissions. The aim of the present paper is to analyse the effect of electricity sector liberalization on the development of distributed generation, and more specifically to examine the conditions in which these new electricity generating technologies can be diffused in a liberalized framework. The paper looks first at how competition has affected the electricity market. This analysis is followed by an examination of the problems of integrating distributed generation into electricity systems. In the third part of the paper, three brief case studies highlight the principal differences between Germany, the United Kingdom and France in the field of distributed generation. This brief analysis reveals that the institutional framework in which distributed generation must operate and the price signals given to electricity sector actors play as big a part as traditional incentives, certificates, bidding systems or guaranteed feed-in tariffs in driving the deployment process. (author)

  6. Strategic bidding of generating units in competitive electricity market with considering their reliability

    International Nuclear Information System (INIS)

    Soleymani, S.; Ranjbar, A.M.; Shirani, A.R.

    2008-01-01

    In the restructured power systems, they are typically scheduled based on the offers and bids to buy and sell energy and ancillary services (AS) subject to operational and security constraints. Generally, no account is taken of unit reliability when scheduling it. Therefore generating units have no incentive to improve their reliability. This paper proposes a new method to obtain the equilibrium points for reliability and price bidding strategy of units when the unit reliability is considered in the scheduling problem. The proposed methodology employs the supply function equilibrium (SFE) for modeling a unit's bidding strategy. Units change their bidding strategies and improve their reliability until Nash equilibrium points are obtained. GAMS (general algebraic modeling system) language has been used to solve the market scheduling problem using DICOPT optimization software with mixed integer non-linear programming. (author)

  7. Electrical Stimulation of the Ventral Tegmental Area Induces Reanimation from General Anesthesia

    Science.gov (United States)

    Solt, Ken; Van Dort, Christa J.; Chemali, Jessica J.; Taylor, Norman E.; Kenny, Jonathan D.; Brown, Emery N.

    2014-01-01

    BACKGROUND Methylphenidate or a D1 dopamine receptor agonist induce reanimation (active emergence) from general anesthesia. We tested whether electrical stimulation of dopaminergic nuclei also induces reanimation from general anesthesia. METHODS In adult rats, a bipolar insulated stainless steel electrode was placed in the ventral tegmental area (VTA, n = 5) or substantia nigra (SN, n = 5). After a minimum 7-day recovery period, the isoflurane dose sufficient to maintain loss of righting was established. Electrical stimulation was initiated and increased in intensity every 3 min to a maximum of 120μA. If stimulation restored the righting reflex, an additional experiment was performed at least 3 days later during continuous propofol anesthesia. Histological analysis was conducted to identify the location of the electrode tip. In separate experiments, stimulation was performed in the prone position during general anesthesia with isoflurane or propofol, and the electroencephalogram was recorded. RESULTS To maintain loss of righting, the dose of isoflurane was 0.9% ± 0.1 vol%, and the target plasma dose of propofol was 4.4 μg/ml ± 1.1 μg/ml (mean ± SD). In all rats with VTA electrodes, electrical stimulation induced a graded arousal response including righting that increased with current intensity. VTA stimulation induced a shift in electroencephalogram peak power from δ (anesthesia with isoflurane or propofol. These results are consistent with the hypothesis that dopamine release by VTA, but not SN, neurons induces reanimation from general anesthesia. PMID:24398816

  8. A general modeling method for I-V characteristics of geometrically and electrically configured photovoltaic arrays

    International Nuclear Information System (INIS)

    Liu Guangyu; Nguang, Sing Kiong; Partridge, Ashton

    2011-01-01

    Highlights: → A novel and general method is proposed for modeling PV arrays or modules. → A robust algorithm is used for the first time to improve the convergence to solution. → Auxiliary functions in other general methods are not compulsory in our method. → It is novel that geometric configuration is also incorporated. → A case study is performed to show the approach's advantages and unique features. - Abstract: A general method for modeling typical photovoltaic (PV) arrays and modules is proposed to find the exact current and voltage relationship of PV arrays or modules of geometrically and electrically different configurations. Nonlinear characteristic equations of electrical devices in solar array or module systems are numerically constructed without adding any virtual electrical components. Then, a robust damped Newton method is used to find exact I-V relationship of these general nonlinear equations, where the convergence is guaranteed. The model can deal with different mismatch effects such as different configurations of bypass diodes, and partial shading. Geometry coordinates of PV components are also considered to facilitate the modeling of the actual physical configuration. Simulation of a PV array with 48 modules, partially shaded by a concrete structure, is performed to verify the effectiveness and advantages of the proposed method.

  9. Incorporating energy efficiency into electric power transmission planning: A western United States case study

    International Nuclear Information System (INIS)

    Barbose, Galen L.; Sanstad, Alan H.; Goldman, Charles A.

    2014-01-01

    Driven by system reliability goals and the need to integrate significantly increased renewable power generation, long-range, bulk-power transmission planning processes in the United States are undergoing major changes. At the same time, energy efficiency is an increasing share of the electricity resource mix in many regions, and has become a centerpiece of many utility resource plans and state policies as a means of meeting electricity demand, complementing supply-side sources, and reducing carbon dioxide emissions from the electric power system. The paper describes an innovative project in the western United States to explicitly incorporate end-use efficiency into load forecasts – projections of electricity consumption and demand – that are a critical input into transmission planning and transmission planning studies. Institutional and regulatory background and context are reviewed, along with a detailed discussion of data sources and analytical procedures used to integrate efficiency into load forecasts. The analysis is intended as a practical example to illustrate the kinds of technical and institutional issues that must be addressed in order to incorporate energy efficiency into regional transmission planning activities. - Highlights: • Incorporating energy efficiency into electric power transmission planning is an emergent analytical and policy priority. • A new methodology for this purpose was developed and applied in the western U.S. transmission system. • Efficiency scenarios were created and incorporated into multiple load forecasts. • Aggressive deployment of efficiency policies and programs can significantly reduce projected load. • The approach is broadly applicable in long-range transmission planning

  10. 75 FR 82414 - Carolina Power & Light Company; H. B. Robinson Steam Electric Plant, Unit No. 2; Exemption

    Science.gov (United States)

    2010-12-30

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-261; NRC-2010-0062] Carolina Power & Light Company; H. B. Robinson Steam Electric Plant, Unit No. 2; Exemption 1.0 Background Carolina Power & Light... authorizes operation of the H.B. Robinson Steam Electric Plant, Unit 2 (HBRSEP). The license provides, among...

  11. 75 FR 11579 - Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2; Exemption

    Science.gov (United States)

    2010-03-11

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-261; NRC-2010-0062] Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2; Exemption 1.0 Background Carolina Power & Light... of the H. B. Robinson Steam Electric Plant, Unit 2 (HBRSEP). The license provides, among other things...

  12. Europe-United States: two diverging evolutions of electricity restructuring? a prospective study on the functioning and the regulation of electrical markets on both sides of the Atlantic

    International Nuclear Information System (INIS)

    Derdevet, M.; Veyrenc, Th.

    2008-01-01

    On both sides of the Atlantic, the same broad purpose was at the heart of electricity restructuring policies: substituting competition to the monopolistic organisation as a means of increased efficiency, and transforming sets of local markets into large continental-wide integrated markets. The current diversity between European and American systems is thus intriguing. The relative homogeneity of electrical systems in the old continent, which is being reinforced by the gradual though delicate elaboration of shared principles on the general organisation of the electricity industry at the European level, compares to a genuine diversity on the American side, where each State remains responsible for conducting its own restructuring policy, even if similar rules on wholesale markets are acknowledged and implemented at a federal level. Yet Europe and the United States face the same kind of issues regarding the future of the energy industry: which status for grid operators, how to respond to growing concerns on security of supply, what to do to mitigate the sharp increase in energy prices? Evidence thereof are the similar attempts by some States to retain direct price control methods, rather than to bank on the virtues of competition to prompt investments in generation and lead prices to drop. It currently appears that the answers to these shared challenges are not converging. On behalf of a comparatively strong freedom of action relatively to the initial competitive paradigm, the array of polio/ responses available in the United States seems broader than in Europe, where the approach recommended by the European Commission consists of further deepening the initial model without altering it. The future will show whether that trend is lasting, or if two structurally different models can emerge from such differences. (authors)

  13. Comparative costs of coal and nuclear-generated electricity in the united states

    International Nuclear Information System (INIS)

    Brandfon, W.W.

    1987-01-01

    This paper compares the future first-year operating costs and lifetime levelized costs of producing baseload coal- and nuclear-generated electricity under schedules shorter than those recently experienced at U.S. plants. Nuclear appears to have a clear economic advantage. Coal is favorable only when it is assumed that the units will operate at very low capacity factors and/or when the capital cost differential between nuclear and coal is increased far above the recent historical level. Nuclear is therefore a cost-competitive electric energy option for utilities and should be considered as an alternative to coal when large baseload capacity is required. (author)

  14. Per unit representation of electrical magnitudes in batteries: A tool for comparison and design

    International Nuclear Information System (INIS)

    Gauchia, Lucia; Sanz, Javier

    2009-01-01

    When a comparison between the performance of batteries with different characteristics, or sizing of a particular battery system in a power system (electrical grid, etc.) is carried out, the usual expression of electrical variables in terms of absolute magnitudes (Volts, etc.) has some important disadvantages derived from the wide range of values these variables can assume, as they are dependant on the 'size' of the system, defined by its rated capacity, voltage or current. This makes impossible any direct comparison between different alternatives. Furthermore, it collides with the usual way power engineers use to represent and analyze the electrical power system. This paper proposes the application of a per unit system to batteries to overcome these problems. In this per unit system, all magnitudes are represented as non-dimensional values, with reference to a set of base magnitudes. Therefore, absolute values are converted into relative ones, which allow a direct comparison between different batteries. To apply a per unit system, a set of base magnitudes is studied and defined taking into account the special characteristics of a battery. The conclusion is that with a per unit system the information extracted is more accessible, direct and representative than using absolute magnitudes

  15. Physical characteristics of GE [General Electric] BWR [boiling-water reactor] fuel assemblies

    International Nuclear Information System (INIS)

    Moore, R.S.; Notz, K.J.

    1989-06-01

    The physical characteristics of fuel assemblies manufactured by the General Electric Company for boiling-water reactors are classified and described. The classification into assembly types is based on the GE reactor product line, the Characteristics Data Base (CDB) assembly class, and the GE fuel design. Thirty production assembly types are identified. Detailed physical data are presented for each assembly type in an appendix. Descriptions of special (nonstandard) fuels are also reported. 52 refs., 1 fig., 6 tabs

  16. [General practice research units in Denmark: multidisciplinary research in support of practical work].

    Science.gov (United States)

    Reventlow, Susanne; Broholm, Katalin Alexa Király; Mäkelä, Marjukka

    2014-01-01

    In Denmark the general practice research units operating in connection with universities provide a home base, training and methodology support for researchers in the field from medical students to general practitioners carrying out practical work. Research issues frequently require a multidisciplinary approach and use of different kinds of materials. Problems arising from the practical work of general practitioners take priority in the wide selection of topics. The units have networked efficiently with organizations of general practitioners and medical education. The combination of research environments has created synergy benefiting everybody and increased the scientific productivity and visibility of the field.

  17. 76 FR 27669 - Penske Logistics LLC, a Subsidiary of General Electric/Penske Corporation Including On-Site...

    Science.gov (United States)

    2011-05-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,897] Penske Logistics LLC, a Subsidiary of General Electric/Penske Corporation Including On-Site Leased Workers From Kelly Temporary... workers and former workers of Penske Logistics LLC, a subsidiary of General Electric/Penske Corporation...

  18. 75 FR 1622 - Decision To Evaluate a Petition To Designate a Class of Employees for the General Electric...

    Science.gov (United States)

    2010-01-12

    ... Employees for the General Electric Company, Evendale, OH, To Be Included in the Special Exposure Cohort... evaluate a petition to designate a class of employees for the General Electric Company, Evendale, Ohio, to... Compensation Program Act of 2000. The initial proposed definition for the class being evaluated, subject to...

  19. 77 FR 13367 - General Electric-Hitachi Global Laser Enrichment, LLC, Proposed Laser-Based Uranium Enrichment...

    Science.gov (United States)

    2012-03-06

    ... NUCLEAR REGULATORY COMMISSION [NRC-2009-0157] General Electric-Hitachi Global Laser Enrichment, LLC, Proposed Laser-Based Uranium Enrichment Facility, Wilmington, NC AGENCY: Nuclear Regulatory... Impact Statement (EIS) for the proposed General Electric- Hitachi Global Laser Enrichment, LLC (GLE...

  20. A General Model for Thermal, Hydraulic and Electric Analysis of Superconducting Cables

    CERN Document Server

    Bottura, L; Rosso, C

    2000-01-01

    In this paper we describe a generic, multi-component and multi-channel model for the analysis of superconducting cables. The aim of the model is to treat in a general and consistent manner simultaneous thermal, electric and hydraulic transients in cables. The model is devised for most general situations, but reduces in limiting cases to most common approximations without loss of efficiency. We discuss here the governing equations, and we write them in a matrix form that is well adapted to numerical treatment. We finally demonstrate the model capability by comparison with published experimental data on current distribution in a two-strand cable.

  1. New representative of the Director-General of the IAEA to the United Nations

    International Nuclear Information System (INIS)

    2000-01-01

    The document gives information about Mr. Kwaku Aning (Ghana) who was nominated as the Representative of the Director-General of the IAEA to the United Nations and as Director of its Office at the United Nations Headquarters in New York, USA, as of 1 February 2000

  2. An analysis of acute admissions to a general hospital psychiatric unit

    African Journals Online (AJOL)

    Rapid turnover of patients in a general hospital psychiatric unit demands stabilization and discharge as soon as possible. It is likely that patients are being prematurely discharged because of this pressure. Aim: The study sought to analyse admissions to an acute psychiatric unit with a view to determining the demographic ...

  3. Economic impacts of electricity liberalization on the status of nuclear power generation in the United States

    International Nuclear Information System (INIS)

    Hattori, Toru

    2015-01-01

    This paper discusses the economic impact of electricity liberalization on the status of nuclear power generation in the United States. Nuclear power plants have been treated equally with other types of power plants in the liberalized electricity market. The existing nuclear power plants were thought to be competitive in liberalized wholesale electricity market. Competitive pressure from the market also facilitated efficiency improvement among the existing nuclear power plants. Although it was difficult to build new reactor, the U.S. nuclear power generators expanded capacity through up rates. In recent years, however, nuclear power plants suffer from the decline in wholesale power prices and some of them are forced to retire early. Although there are some market design issues that could be improved to maintain the efficient nuclear power plants in competitive environment, it is now argued that some additional arrangements to mitigate the investment risks of the nuclear power plants are necessary. (author)

  4. Instrumentation and electrical program at the Three Mile Island Unit 2, Technical Integration Office

    International Nuclear Information System (INIS)

    Hecker, L.A.

    1982-01-01

    The Three Mile Island Unit 2 accident of March 28, 1979 presents unique research opportunities that can provide valuable information on nuclear power plant safety philosophy and safety systems performance. The Technical Integration Office at Three Mile Island was established by the Department of Energy to manage a broad-based research and development program. One significant part of this effort is the Instrumentation and Electrical Program, which operates: (1) to identify instruments and electrical components that failed during or since the accident; (2) to test and analyze them in order to identify the causes of failure; and (3) to assess the survivability of those that did not fail. The basis for selection of equipment is discussed, and the testing methodology is described. Also, some results of Instrumentation and Electrical Program work to date are presented

  5. Physiological recruitment of motor units by high-frequency electrical stimulation of afferent pathways.

    Science.gov (United States)

    Dideriksen, Jakob L; Muceli, Silvia; Dosen, Strahinja; Laine, Christopher M; Farina, Dario

    2015-02-01

    Neuromuscular electrical stimulation (NMES) is commonly used in rehabilitation, but electrically evoked muscle activation is in several ways different from voluntary muscle contractions. These differences lead to challenges in the use of NMES for restoring muscle function. We investigated the use of low-current, high-frequency nerve stimulation to activate the muscle via the spinal motoneuron (MN) pool to achieve more natural activation patterns. Using a novel stimulation protocol, the H-reflex responses to individual stimuli in a train of stimulation pulses at 100 Hz were reliably estimated with surface EMG during low-level contractions. Furthermore, single motor unit recruitment by afferent stimulation was analyzed with intramuscular EMG. The results showed that substantially elevated H-reflex responses were obtained during 100-Hz stimulation with respect to a lower stimulation frequency. Furthermore, motor unit recruitment using 100-Hz stimulation was not fully synchronized, as it occurs in classic NMES, and the discharge rates differed among motor units because each unit was activated only after a specific number of stimuli. The most likely mechanism behind these observations is the temporal summation of subthreshold excitatory postsynaptic potentials from Ia fibers to the MNs. These findings and their interpretation were also verified by a realistic simulation model of afferent stimulation of a MN population. These results suggest that the proposed stimulation strategy may allow generation of considerable levels of muscle activation by motor unit recruitment that resembles the physiological conditions. Copyright © 2015 the American Physiological Society.

  6. A comprehensive overview of hybrid electric vehicle: Powertrain configurations, powertrain control techniques and electronic control units

    Energy Technology Data Exchange (ETDEWEB)

    Cagatay Bayindir, Kamil; Goezuekuecuek, Mehmet Ali; Teke, Ahmet [Cukurova University, Department of Electrical and Electronics Engineering, Balcali, Saricam, Adana (Turkey)

    2011-02-15

    The studies for hybrid electrical vehicle (HEV) have attracted considerable attention because of the necessity of developing alternative methods to generate energy for vehicles due to limited fuel based energy, global warming and exhaust emission limits in the last century. HEV incorporates internal composition engine, electric machines and power electronic equipments. In this study, overview of HEVs with a focus on hybrid configurations, energy management strategies and electronic control units are presented. Advantages and disadvantages of each configuration are clearly emphasized. The existing powertrain control techniques for HEVs are classified and comprehensively described. Electronic control units used in HEV configuration are also elaborated. The latest trends and technological challenges in the near future for HEVs are discussed. (author)

  7. Comparison of the General Electric BWR/6 standard plant design to the IAEA NUSS codes and guides

    International Nuclear Information System (INIS)

    D'Ardenne, W.H.; Sherwood, G.G.

    1985-01-01

    The General Electric BWR/6 Mark III standard plant design meets or exceeds current requirements of published International Atomic Energy Agency (IAEA) Nuclear Safety Standards (NUSS) codes and guides. This conclusion is based on a review of the NUSS codes and guides by General Electric and by the co-ordinated US review of the NUSS codes and guides during their development. General Electric compared the published IAEA NUSS codes and guides with the General Electric design. The applicability of each code and guide to the BWR/6 Mark III standard plant design was determined. Each code or guide was reviewed by a General Electric engineer knowledgeable about the structures, systems and components addressed and the technical area covered by that code or guide. The results of this review show that the BWR/6 Mark III standard plant design meets or exceeds the applicable requirements of the published IAEA NUSS codes and guides. The co-ordinated US review of the IAEA NUSS codes and guides corroborates the General Electric review. In the co-ordinated US review, the USNRC and US industry organizations (including General Electric) review the NUSS codes and guides during their development. This review ensures that the NUSS codes and guides are consistent with the current US government regulations, guidance and regulatory practices, US voluntary industry codes and standards, and accepted US industry design, construction and operational practices. If any inconsistencies are identified, comments are submitted to the IAEA by the USNRC. All US concerns submitted to the IAEA have been resolved. General Electric design reviews and the Final Design Approval (FDA) issued by the USNRC have verified that the General Electric BWR/6 Mark III standard plant design meets or exceeds the current US requirements, guidance and practices. Since these requirements, guidance and practices meet or exceed those of the NUSS codes and guides, so does the General Electric design. (author)

  8. Modernization of electrical systems in NPP Kozloduy unit 5 and 6. Feedback of experience

    International Nuclear Information System (INIS)

    Stinshoff, H.

    2005-01-01

    In the frame of the modernization program for the nuclear power plant Kozloduy unit 5 and 6 Framatome ANP has implemented measures to increase the safety and availability of the electrical systems. The hardware installation is scheduled in the refueling outages of the years 2003 to 2005. In this paper the following items are presented: 1) an overview of the modernization measures; 2) some important technical features of the new equipment and diagnostic measures; 3) feedback of experience

  9. Technical Specifications, Comanche Peak Steam Electric Station, Unit 1 (Docket No. 50-445)

    International Nuclear Information System (INIS)

    1990-04-01

    The Technical Specifications for Comanche Peak Steam Electric Station, Unit 1 were prepared by the US Nuclear Regulatory Commission. They set forth the limits, operating conditions, and other requirements applicable to a nuclear reactor facility, as set forth in Section 50.36 of Title 10 of the Code of Federal Regulations Part 50, for the protection of the health and safety of the public

  10. Emissions implications of downscaled electricity generation scenarios for the western United States

    Energy Technology Data Exchange (ETDEWEB)

    Nsanzineza, Rene; O’Connell, Matthew; Brinkman, Gregory; Milford, Jana B.

    2017-10-01

    This study explores how emissions from electricity generation in the Western Interconnection region of the U.S. might respond in circa 2030 to contrasting scenarios for fuel prices and greenhouse gas (GHG) emissions fees. We examine spatial and temporal variations in generation mix across the region and year using the PLEXOS unit commitment and dispatch model with a production cost model database adapted from the Western Electricity Coordinating Council. Emissions estimates are computed by combining the dispatch model results with unit-specific, emissions-load relationships. Wind energy displaces natural gas and coal in scenarios with relatively expensive natural gas or with GHG fees. Correspondingly, annual emissions of NOx, SO2, and CO2 are reduced by 20-40% in these cases. NOx emissions, which are a concern as a precursor of ground-level ozone, are relatively high and consistent across scenarios during summer, when peak electricity loads occur and wind resources in the region are comparatively weak. Accounting for the difference in start-up versus stabilized NOx emissions rates for natural gas plants had little impact on region-wide emissions estimates due to the dominant contribution from coal-fired plants, but would be more important in the vicinity of the natural gas units.

  11. A general electromagnetic excitation model for electrical machines considering the magnetic saturation and rub impact

    Science.gov (United States)

    Xu, Xueping; Han, Qinkai; Chu, Fulei

    2018-03-01

    The electromagnetic vibration of electrical machines with an eccentric rotor has been extensively investigated. However, magnetic saturation was often neglected. Moreover, the rub impact between the rotor and stator is inevitable when the amplitude of the rotor vibration exceeds the air-gap. This paper aims to propose a general electromagnetic excitation model for electrical machines. First, a general model which takes the magnetic saturation and rub impact into consideration is proposed and validated by the finite element method and reference. The dynamic equations of a Jeffcott rotor system with electromagnetic excitation and mass imbalance are presented. Then, the effects of pole-pair number and rubbing parameters on vibration amplitude are studied and approaches restraining the amplitude are put forward. Finally, the influences of mass eccentricity, resultant magnetomotive force (MMF), stiffness coefficient, damping coefficient, contact stiffness and friction coefficient on the stability of the rotor system are investigated through the Floquet theory, respectively. The amplitude jumping phenomenon is observed in a synchronous generator for different pole-pair numbers. The changes of design parameters can alter the stability states of the rotor system and the range of parameter values forms the zone of stability, which lays helpful suggestions for the design and application of the electrical machines.

  12. Rejecting renewables: The socio-technical impediments to renewable electricity in the United States

    International Nuclear Information System (INIS)

    Sovacool, Benjamin K.

    2009-01-01

    If renewable power systems deliver such impressive benefits, why do they still provide only 3 percent of national electricity generation in the United States? As an answer, this article demonstrates that the impediments to renewable power are socio-technical, a term that encompasses the technological, social, political, regulatory, and cultural aspects of electricity supply and use. Extensive interviews of public utility commissioners, utility managers, system operators, manufacturers, researchers, business owners, and ordinary consumers reveal that it is these socio-technical barriers that often explain why wind, solar, biomass, geothermal, and hydroelectric power sources are not embraced. Utility operators reject renewable resources because they are trained to think only in terms of big, conventional power plants. Consumers practically ignore renewable power systems because they are not given accurate price signals about electricity consumption. Intentional market distortions (such as subsidies), and unintentional market distortions (such as split incentives) prevent consumers from becoming fully invested in their electricity choices. As a result, newer and cleaner technologies that may offer social and environmental benefits but are not consistent with the dominant paradigm of the electricity industry continue to face comparative rejection.

  13. Rejecting renewables. The socio-technical impediments to renewable electricity in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Sovacool, Benjamin K. [Energy Governance Program, Centre on Asia and Globalisation, Lee Kuan Yew School of Public Policy, National University of Singapore (Singapore)

    2009-11-15

    If renewable power systems deliver such impressive benefits, why do they still provide only 3 percent of national electricity generation in the United States? As an answer, this article demonstrates that the impediments to renewable power are socio-technical, a term that encompasses the technological, social, political, regulatory, and cultural aspects of electricity supply and use. Extensive interviews of public utility commissioners, utility managers, system operators, manufacturers, researchers, business owners, and ordinary consumers reveal that it is these socio-technical barriers that often explain why wind, solar, biomass, geothermal, and hydroelectric power sources are not embraced. Utility operators reject renewable resources because they are trained to think only in terms of big, conventional power plants. Consumers practically ignore renewable power systems because they are not given accurate price signals about electricity consumption. Intentional market distortions (such as subsidies), and unintentional market distortions (such as split incentives) prevent consumers from becoming fully invested in their electricity choices. As a result, newer and cleaner technologies that may offer social and environmental benefits but are not consistent with the dominant paradigm of the electricity industry continue to face comparative rejection. (author)

  14. Rejecting renewables: The socio-technical impediments to renewable electricity in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Sovacool, Benjamin K., E-mail: bsovacool@nus.edu.s [Energy Governance Program, Centre on Asia and Globalisation, Lee Kuan Yew School of Public Policy, National University of Singapore (Singapore)

    2009-11-15

    If renewable power systems deliver such impressive benefits, why do they still provide only 3 percent of national electricity generation in the United States? As an answer, this article demonstrates that the impediments to renewable power are socio-technical, a term that encompasses the technological, social, political, regulatory, and cultural aspects of electricity supply and use. Extensive interviews of public utility commissioners, utility managers, system operators, manufacturers, researchers, business owners, and ordinary consumers reveal that it is these socio-technical barriers that often explain why wind, solar, biomass, geothermal, and hydroelectric power sources are not embraced. Utility operators reject renewable resources because they are trained to think only in terms of big, conventional power plants. Consumers practically ignore renewable power systems because they are not given accurate price signals about electricity consumption. Intentional market distortions (such as subsidies), and unintentional market distortions (such as split incentives) prevent consumers from becoming fully invested in their electricity choices. As a result, newer and cleaner technologies that may offer social and environmental benefits but are not consistent with the dominant paradigm of the electricity industry continue to face comparative rejection.

  15. Geothermal electric power generation in Iceland for the proposed Iceland/United Kingdom HVDC power link

    International Nuclear Information System (INIS)

    Hammons, T.J.; Palmason, G.; Thorhallsson, S.

    1991-01-01

    The paper reviews geothermal electric power potential in Iceland which could economically be developed to supplement hydro power for the proposed HVDC Power Link to the United Kingdom, and power intensive industries in Iceland, which are envisaged for development at this time. Technically harnessable energy for electricity generation taking account of geothermal resources down to an assumed base depth, temperature distribution in the crust, probable geothermal recovery factor, and accessibility of the field, has been assessed. Nineteen known high-temperature fields and 9 probable fields have been identified. Technically harnessable geo-heat for various areas is indicated. Data on high temperature fields suitable for geothermal electric power generation, and on harnessable energy for electric power generation within volcanic zones, is stated, and overall assessments are made. The paper then reviews how the potential might be developed, discussing preference of possible sites, and cost of the developments at todays prices. Cost of geothermal electric power generation with comparative costs for hydro generation are given. Possible transmission system developments to feed the power to the proposed HVDC Link converter stations are also discussed

  16. Disparities in access to emergency general surgery care in the United States.

    Science.gov (United States)

    Khubchandani, Jasmine A; Shen, Connie; Ayturk, Didem; Kiefe, Catarina I; Santry, Heena P

    2018-02-01

    As fewer surgeons take emergency general surgery call and hospitals decrease emergency services, a crisis in access looms in the United States. We examined national emergency general surgery capacity and county-level determinants of access to emergency general surgery care with special attention to disparities. To identify potential emergency general surgery hospitals, we queried the database of the American Hospital Association for "acute care general hospital," with "surgical services," and "emergency department," and ≥1 "operating room." Internet search and direct contact confirmed emergency general surgery services that covered the emergency room 7 days a week, 24 hours a day. Geographic and population-level emergency general surgery access was derived from Geographic Information Systems and US Census. Of the 6,356 hospitals in the 2013 American Hospital Association database, only 2,811 were emergency general surgery hospitals. Counties with greater percentages of black, Hispanic, uninsured, and low-education individuals and rural counties disproportionately lacked access to emergency general surgery care. For example, counties above the 75th percentile of African American population (10.2%) had >80% odds of not having an emergency general surgery hospital compared with counties below the 25th percentile of African American population (0.6%). Gaps in access to emergency general surgery services exist across the United States, disproportionately affecting underserved, rural communities. Policy initiatives need to increase emergency general surgery capacity nationwide. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. RichMol: A general variational approach for rovibrational molecular dynamics in external electric fields

    Science.gov (United States)

    Owens, Alec; Yachmenev, Andrey

    2018-03-01

    In this paper, a general variational approach for computing the rovibrational dynamics of polyatomic molecules in the presence of external electric fields is presented. Highly accurate, full-dimensional variational calculations provide a basis of field-free rovibrational states for evaluating the rovibrational matrix elements of high-rank Cartesian tensor operators and for solving the time-dependent Schrödinger equation. The effect of the external electric field is treated as a multipole moment expansion truncated at the second hyperpolarizability interaction term. Our fully numerical and computationally efficient method has been implemented in a new program, RichMol, which can simulate the effects of multiple external fields of arbitrary strength, polarization, pulse shape, and duration. Illustrative calculations of two-color orientation and rotational excitation with an optical centrifuge of NH3 are discussed.

  18. A general circuit model for spintronic devices under electric and magnetic fields

    KAUST Repository

    Alawein, Meshal

    2017-10-25

    In this work, we present a circuit model of diffusive spintronic devices capable of capturing the effects of both electric and magnetic fields. Starting from a modified version of the well-established drift-diffusion equations, we derive general equivalent circuit models of semiconducting/metallic nonmagnets and metallic ferromagnets. In contrast to other models that are based on steady-state transport equations which might also neglect certain effects such as thermal fluctuations, spin dissipation in the ferromagnets, and spin precession under magnetic fields, our model incorporates most of the important physics and is based on a time-dependent formulation. An application of our model is shown through simulations of a nonlocal spin-valve under the presence of a magnetic field, where we reproduce experimental results of electrical measurements that demonstrate the phenomena of spin precession and dephasing (“Hanle effect”).

  19. Evolution of the Power Processing Units Architecture for Electric Propulsion at CRISA

    Science.gov (United States)

    Palencia, J.; de la Cruz, F.; Wallace, N.

    2008-09-01

    Since 2002, the team formed by EADS Astrium CRISA, Astrium GmbH Friedrichshafen, and QinetiQ has participated in several flight programs where the Electric Propulsion based on Kaufman type Ion Thrusters is the baseline conceptOn 2002, CRISA won the contract for the development of the Ion Propulsion Control Unit (IPCU) for GOCE. This unit together with the T5 thruster by QinetiQ provides near perfect atmospheric drag compensation offering thrust levels in the range of 1 to 20mN.By the end of 2003, CRISA started the adaptation of the IPCU concept to the QinetiQ T6 Ion Thruster for the Alphabus program.This paper shows how the Power Processing Unit design evolved in time including the current developments.

  20. Implications of water constraints for electricity capacity expansion in the United States

    Science.gov (United States)

    Liu, L.; Hejazi, M. I.; Iyer, G.; Forman, B. A.

    2017-12-01

    U.S. electricity generation is vulnerable to water supply since water is required for cooling. Constraints on the availability of water will therefore necessitate adaptive planning by the power generation sector. Hence, it is important to integrate restrictions in water availability in electricity capacity planning in order to better understand the economic viability of alternative capacity planning options. The study of the implications of water constraints for the U.S. power generation system is limited in terms of scale and robustness. We extend previous studies by including physical water constraints in a state-level model of the U.S. energy system embedded within a global integrated assessment model (GCAM-USA). We focus on the implications of such constraints for the U.S. electricity capacity expansion, integrating both supply and demand effects under a consistent framework. Constraints on the availability of water have two general effects across the U.S. First, water availability constraints increase the cost of electricity generation, resulting in reduced electrification of end-use sectors. Second, water availability constraints result in forced retirements of water-intensive technologies such as thermoelectric coal- and gas- fired technologies before the end of their natural lifetimes. The demand for electricity is then met by an increase in investments in less water-dependent technologies such as wind and solar photovoltaic. Our results show that the regional patterns of the above effects are heterogeneous across the U.S. In general, the impacts of water constraints on electricity capacity expansion are more pronounced in the West than in the East. This is largely because of lower water availability in the West compared to the East due to lower precipitation in the Western states. Constraints on the availability of water might also have important implications for U.S. electricity trade. For example, under severe constraints on the availability of water

  1. Attitudes of the general public and electric power company employees toward nuclear power generation

    International Nuclear Information System (INIS)

    Komiyama, Hisashi

    1997-01-01

    We conducted an awareness survey targeted at members of the general public residing in urban areas and in areas scheduled for construction of nuclear power plants as well as employees of electric power company in order to determine the awareness and attitude structures of people residing near scheduled construction sites of nuclear power plants with respect to nuclear power generation, and to examine ways of making improvements in terms of promoting nuclear power plant construction sites. Analysis of those results revealed that there are no significant differences in the awareness and attitudes of people residing in urban areas and in areas near scheduled construction sites. On the contrary, a general sense of apprehension regarding the construction of nuclear power plants was observed common to both groups. In addition, significant differences in awareness and attitudes with respect to various factors were determined to exist between members of the general public residing in urban areas and scheduled construction sites and employees of electric power company. (author)

  2. Critique of the electricity industry. Research report ERG 013. [In United Kingdom

    Energy Technology Data Exchange (ETDEWEB)

    1976-03-01

    The studies described in this report were begun in October 1975 and had the aim of examining the future role of the electricity industry in the light of the changes in fuel prices and the government's ''Save It'' campaign. As the study proceeded, it became obvious that the electricity industry was facing a crisis which threatened a number of government policies. The essence of this crisis is a declining demand for electricity coupled with an installed capacity 55 percent greater than required to meet peak demand. The most obvious solution to the electricity industry's problems is to promote vigorously electricity sales so as to improve its revenue and maintain the growth in number of power stations. This is clearly in conflict with the ''Save It'' campaign and likely to increase the U.K.'s consumption of oil. The alternative solution, namely to raise the price of electricity and drastically reduce orders for new power stations, is in conflict with the government's policies aimed at curbing inflation and unemployment. Thus the study was enlarged to encompass not only the role of electricity in a national fuel policy but also to examine policies which would alleviate the worst effects of the immediate crisis without prejudicing either short-term economic objectives or longer-term fuel policies. Part 2, Technical Factors, explains technical issues involved in the discussions. Part 3, Industry Problems, sets out the problems as seen by the industry and the explanation of how the industry came to its present position. Part 4, Consumer Problems, explains the nature of customers problems and how government services and pricing policies could be used to alleviate these. Part 5, Government Policy, shows the need for an integrated fuel policy and the general direction that the studies suggest this policy should take. Conclusions are summarized in Part 6. (MCW)

  3. A generalized transformation to convert an arbitrary perfect electric conductor into another arbitrary dielectric object

    International Nuclear Information System (INIS)

    Huang Lujun; Zhou Daming; Wang Jian; Li Guanhai; Li Zhifeng; Chen Xiaoshuang; Lu Wei

    2011-01-01

    A generalized transformation is proposed to design an illusion device. The device can reshape an arbitrarily shaped perfect electrical conductor (PEC) into another dielectric object with arbitrary geometry. Such a device can evolve into an ideal invisibility cloak with non-conformal boundaries if the virtual space is filled with air. Furthermore, the validity of our proposed transformation is confirmed by two specific devices. One is to convert a regular polygonal PEC cylinder into a circular dielectric cylinder. Another one is to reshape a circular PEC cylinder into a regular polygonal dielectric cylinder.

  4. Confined electron assemblies in intense electric and magnetic fields and a generalization of Emden's equation

    International Nuclear Information System (INIS)

    March, N.H.

    2003-09-01

    The Feynman propagator, and its parallel in statistical mechanics, namely the canonical density matrix, are first used to treat both homogeneous and confined electron assemblies in the presence of a static electric field of arbitrary strength. The models are relevant to plasmas having variable electron density and degeneracy. The second topic concerns atomic ions in intense magnetic fields. Semiclassical theory is here applied, non-relativistic and relativistic approximations being invoked. Both treatments are shown to be embraced by a generalization of Emden's equation. (author)

  5. Regional Variability and Uncertainty of Electric Vehicle Life Cycle CO₂ Emissions across the United States.

    Science.gov (United States)

    Tamayao, Mili-Ann M; Michalek, Jeremy J; Hendrickson, Chris; Azevedo, Inês M L

    2015-07-21

    We characterize regionally specific life cycle CO2 emissions per mile traveled for plug-in hybrid electric vehicles (PHEVs) and battery electric vehicles (BEVs) across the United States under alternative assumptions for regional electricity emission factors, regional boundaries, and charging schemes. We find that estimates based on marginal vs average grid emission factors differ by as much as 50% (using National Electricity Reliability Commission (NERC) regional boundaries). Use of state boundaries versus NERC region boundaries results in estimates that differ by as much as 120% for the same location (using average emission factors). We argue that consumption-based marginal emission factors are conceptually appropriate for evaluating the emissions implications of policies that increase electric vehicle sales or use in a region. We also examine generation-based marginal emission factors to assess robustness. Using these two estimates of NERC region marginal emission factors, we find the following: (1) delayed charging (i.e., starting at midnight) leads to higher emissions in most cases due largely to increased coal in the marginal generation mix at night; (2) the Chevrolet Volt has higher expected life cycle emissions than the Toyota Prius hybrid electric vehicle (the most efficient U.S. gasoline vehicle) across the U.S. in nearly all scenarios; (3) the Nissan Leaf BEV has lower life cycle emissions than the Prius in the western U.S. and in Texas, but the Prius has lower emissions in the northern Midwest regardless of assumed charging scheme and marginal emissions estimation method; (4) in other regions the lowest emitting vehicle depends on charge timing and emission factor estimation assumptions.

  6. Electrical Spectroscopy of Permo-Triassic Sandstone From the United Kingdom

    Science.gov (United States)

    Scott, J.; Barker, R.

    2003-12-01

    Electrical spectroscopy measurements in the range of mHz to kHz have been made on the dominantly red Permo-Triassic sandstone from the United Kingdom. Samples have been selected from borehole cores from all of the main outcrop areas of sandstone and represent a wide variety of lithologies. This sandstone is an important aquifer for several major cities including Manchester and Birmingham. The samples have been fully saturated with sodium chloride brines and a synthetic groundwater solution that is higher in calcium and magnesium ions than sodium and which closely matches the cation concentrations of the groundwater at Birmingham. Electrical measurements were made using a four-electrode arrangement of silver-silver chloride electrodes. Most of the electrical spectra show a clear, slightly asymmetric, electrical relaxation phenomenon with relaxation peaks in the range of 0.001 Hz to 20 Hz. These relaxation phenomena can be fitted very well by a generalised Cole-Cole model. The relaxation time from this model is found to correlate closely with the dominant pore-throat size from mercury injection. Normalising the chargeability, Cole-Cole m parameter, by the conductivity gives a polarisation magnitude which correlates well with the pore surface to volume ratio (SPOR) for sandstone samples with an even distribution of surface coating clays. The information obtained from the electrical spectra is very useful. The pore-throat size is important in controlling the permeability and in particular the flow of non-aqueous phase fluids. The pore surface area has links to the sorbtion properties of the rock, which are important in estimating contaminant transport. The electrical spectra also provide a useful fingerprint of individual lithologies which could be used for correlation between boreholes or outcrops.

  7. A closed Brayton power conversion unit concept for nuclear electric propulsion for deep space missions

    International Nuclear Information System (INIS)

    Joyner, Claude Russell II; Fowler, Bruce; Matthews, John

    2003-01-01

    In space, whether in a stable satellite orbit around a planetary body or traveling as a deep space exploration craft, power is just as important as the propulsion. The need for power is especially important for in-space vehicles that use Electric Propulsion. Using nuclear power with electric propulsion has the potential to provide increased payload fractions and reduced mission times to the outer planets. One of the critical engineering and design aspects of nuclear electric propulsion at required mission optimized power levels is the mechanism that is used to convert the thermal energy of the reactor to electrical power. The use of closed Brayton cycles has been studied over the past 30 or years and shown to be the optimum approach for power requirements that range from ten to hundreds of kilowatts of power. It also has been found to be scalable to higher power levels. The Closed Brayton Cycle (CBC) engine power conversion unit (PCU) is the most flexible for a wide range of power conversion needs and uses state-of-the-art, demonstrated engineering approaches. It also is in use with many commercial power plants today. The long life requirements and need for uninterrupted operation for nuclear electric propulsion demands high reliability from a CBC engine. A CBC engine design for use with a Nuclear Electric Propulsion (NEP) system has been defined based on Pratt and Whitney's data from designing long-life turbo-machines such as the Space Shuttle turbopumps and military gas turbines and the use of proven integrated control/health management systems (EHMS). An integrated CBC and EHMS design that is focused on using low-risk and proven technologies will over come many of the life-related design issues. This paper will discuss the use of a CBC engine as the power conversion unit coupled to a gas-cooled nuclear reactor and the design trends relative to its use for powering electric thrusters in the 25 kWe to 100kWe power level

  8. Overview of the electricity and gas markets in the United States

    International Nuclear Information System (INIS)

    Speyer, J.M.

    1998-01-01

    The driving forces behind electricity and gas restructuring in the United States are primarily economic. Restructuring legislation regarding the electric power industry has been enacted in fourteen states, and similar legislation is under consideration in most other states. Currently, only three states do not have a significant restructuring plan. With regard to natural gas, market restructuring of the entire gas market is underway in five states, and studies or limited utility retail unbundling pilot programs are underway in seventeen others. It was predicted that restructuring will spread nationwide because once competition begins, it is hard to draw boundaries around it. Mergers are part of the restructuring process, providing firms with a scale that would allow them to undertake strategic initiatives. Convergence, on the other hand, is a response to the 'commoditization' of electricity and gas. As a development in the opposite direction, suppliers of electricity and gas are now attempting to 'decommoditize' their products by brand differentiation and other 'value added' services as a means of developing and retaining customer loyalty. 3 tabs., 2 figs

  9. Overview of the electricity and gas markets in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Speyer, J.M. [Putnam, Hayes and Bartlett Inc., Washington, DC (United States)

    1998-09-01

    The driving forces behind electricity and gas restructuring in the United States are primarily economic. Restructuring legislation regarding the electric power industry has been enacted in fourteen states, and similar legislation is under consideration in most other states. Currently, only three states do not have a significant restructuring plan. With regard to natural gas, market restructuring of the entire gas market is underway in five states, and studies or limited utility retail unbundling pilot programs are underway in seventeen others. It was predicted that restructuring will spread nationwide because once competition begins, it is hard to draw boundaries around it. Mergers are part of the restructuring process, providing firms with a scale that would allow them to undertake strategic initiatives. Convergence, on the other hand, is a response to the `commoditization` of electricity and gas. As a development in the opposite direction, suppliers of electricity and gas are now attempting to `decommoditize` their products by brand differentiation and other `value added` services as a means of developing and retaining customer loyalty. 3 tabs., 2 figs.

  10. Generalized Bohm’s criterion and negative anode voltage fall in electric discharges

    Energy Technology Data Exchange (ETDEWEB)

    Londer, Ya. I.; Ul’yanov, K. N., E-mail: kulyanov@vei.ru [Lenin All-Russian Electrotechnical Institute (Russian Federation)

    2013-10-15

    The value of the voltage fall across the anode sheath is found as a function of the current density. Analytic solutions are obtained in a wide range of the ratio of the directed velocity of plasma electrons v{sub 0} to their thermal velocity v{sub T}. It is shown that the voltage fall in a one-dimensional collisionless anode sheath is always negative. At the small values of v{sub 0}/v{sub T}, the obtained expression asymptotically transforms into the Langmuir formula. Generalized Bohm’s criterion for an electric discharge with allowance for the space charge density ρ(0), electric field E(0), ion velocity v{sub i}(0), and ratio v{sub 0}/v{sub T} at the plasma-sheath interface is formulated. It is shown that the minimum value of the ion velocity v{sub i}{sup *}(0) corresponds to the vanishing of the electric field at one point inside the sheath. The dependence of v{sub i}{sup *} (0) on ρ(0), E(0), and v{sub 0}/v{sub T} determines the boundary of the existence domain of stationary solutions in the sheath. Using this criterion, the maximum possible degree of contraction of the electron current at the anode is determined for a short high-current vacuum arc discharge.

  11. Generalized Bohm’s criterion and negative anode voltage fall in electric discharges

    International Nuclear Information System (INIS)

    Londer, Ya. I.; Ul’yanov, K. N.

    2013-01-01

    The value of the voltage fall across the anode sheath is found as a function of the current density. Analytic solutions are obtained in a wide range of the ratio of the directed velocity of plasma electrons v 0 to their thermal velocity v T . It is shown that the voltage fall in a one-dimensional collisionless anode sheath is always negative. At the small values of v 0 /v T , the obtained expression asymptotically transforms into the Langmuir formula. Generalized Bohm’s criterion for an electric discharge with allowance for the space charge density ρ(0), electric field E(0), ion velocity v i (0), and ratio v 0 /v T at the plasma-sheath interface is formulated. It is shown that the minimum value of the ion velocity v i * (0) corresponds to the vanishing of the electric field at one point inside the sheath. The dependence of v i * (0) on ρ(0), E(0), and v 0 /v T determines the boundary of the existence domain of stationary solutions in the sheath. Using this criterion, the maximum possible degree of contraction of the electron current at the anode is determined for a short high-current vacuum arc discharge

  12. Electricity without carbon dioxide: Assessing the role of carbon capture and sequestration in United States electric markets

    Science.gov (United States)

    Johnson, Timothy Lawrence

    2002-09-01

    Stabilization of atmospheric greenhouse gas concentrations will likely require significant cuts in electric sector carbon dioxide (CO2) emissions. The ability to capture and sequester CO2 in a manner compatible with today's fossil-fuel based power generating infrastructure offers a potentially low-cost contribution to a larger climate change mitigation strategy. This thesis fills a niche between economy-wide studies of CO 2 abatement and plant-level control technology assessments by examining the contribution that carbon capture and sequestration (CCS) might make toward reducing US electric sector CO2 emissions. The assessment's thirty year perspective ensures that costs sunk in current infrastructure remain relevant and allows time for technological diffusion, but remains free of assumptions about the emergence of unidentified radical innovations. The extent to which CCS might lower CO2 mitigation costs will vary directly with the dispatch of carbon capture plants in actual power-generating systems, and will depend on both the retirement of vintage capacity and competition from abatement alternatives such as coal-to-gas fuel switching and renewable energy sources. This thesis therefore adopts a capacity planning and dispatch model to examine how the current distribution of generating units, natural gas prices, and other industry trends affect the cost of CO2 control via CCS in an actual US electric market. The analysis finds that plants with CO2 capture consistently provide significant reductions in base-load emissions at carbon prices near 100 $/tC, but do not offer an economical means of meeting peak demand unless CO2 reductions in excess of 80 percent are required. Various scenarios estimate the amount by which turn-over of the existing generating infrastructure and the severity of criteria pollutant constraints reduce mitigation costs. A look at CO2 sequestration in the seabed beneath the US Outer Continental Shelf (OCS) complements this model

  13. Electrical stimulation site influences the spatial distribution of motor units recruited in tibialis anterior.

    Science.gov (United States)

    Okuma, Yoshino; Bergquist, Austin J; Hong, Mandy; Chan, K Ming; Collins, David F

    2013-11-01

    To compare the spatial distribution of motor units recruited in tibialis anterior (TA) when electrical stimulation is applied over the TA muscle belly versus the common peroneal nerve trunk. Electromyography (EMG) was recorded from the surface and from fine wires in superficial and deep regions of TA. Separate M-wave recruitment curves were constructed for muscle belly and nerve trunk stimulation. During muscle belly stimulation, significantly more current was required to generate M-waves that were 5% of the maximal M-wave (M max; M5%max), 50% M max (M 50%max) and 95% M max (M 95%max) at the deep versus the superficial recording site. In contrast, during nerve trunk stimulation, there were no differences in the current required to reach M5%max, M 50%max or M 95%max between deep and superficial recording sites. Surface EMG reflected activity in both superficial and deep muscle regions. Stimulation over the muscle belly recruited motor units from superficial to deep with increasing stimulation amplitude. Stimulation over the nerve trunk recruited superficial and deep motor units equally, regardless of stimulation amplitude. These results support the idea that where electrical stimulation is applied markedly affects how contractions are produced and have implications for the interpretation of surface EMG data. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  14. Troubleshooting the General Electric Company Neutron Devices Department's deionized water system

    International Nuclear Information System (INIS)

    Gillespie, T.J.

    1983-01-01

    In May 1982, the General Electric Neutron Devices Department's deionized (DI) water system was found to be highly contaminated with fresh water roundworms which caused severe filter plugging problems. Subsequently, a DI water improvement program was developed by GEND's Process Technology, Contamination Control, and Facilities Engineering groups. This program included removal of dead ends in the distribution system, a consultant's review, significant modification of the DI water system, modification of system operation, design of a quality plan, and changes in the types of water analysis. During implementation of the improvement program, a severe bacteria contamination problem occurred due to a contractor accident. Correction of this problem required sterilization of portions of the DI water system and significant modification of the water filtration system. The system modifications and sterilization procedures have significantly reduced bacteria and total solids contamination while resistivity is generally increasing

  15. Replacement energy costs for nuclear electricity-generating units in the United States: 1997--2001. Volume 4

    International Nuclear Information System (INIS)

    VanKuiken, J.C.; Guziel, K.A.; Tompkins, M.M.; Buehring, W.A.

    1997-09-01

    This report updates previous estimates of replacement energy costs for potential short-term shutdowns of 109 US nuclear electricity-generating units. This information was developed to assist the US Nuclear Regulatory Commission (NRC) in its regulatory impact analyses, specifically those that examine the impacts of proposed regulations requiring retrofitting of or safety modifications to nuclear reactors. Such actions might necessitate shutdowns of nuclear power plants while these changes are being implemented. The change in energy cost represents one factor that the NRC must consider when deciding to require a particular modification. Cost estimates were derived from probabilistic production cost simulations of pooled utility system operations. Factors affecting replacement energy costs, such as random unit failures, maintenance and refueling requirements, and load variations, are treated in the analysis. This report describes an abbreviated analytical approach as it was adopted to update the cost estimates published in NUREG/CR-4012, Vol. 3. The updates were made to extend the time frame of cost estimates and to account for recent changes in utility system conditions, such as change in fuel prices, construction and retirement schedules, and system demand projects

  16. Corrosion of packaged cadmium plated electrical control units from paint vapors

    International Nuclear Information System (INIS)

    Brough, L.A.

    1987-01-01

    One of the most widely used methods of controlling the degradation of steel is the application of paint. It is relatively easy to accomplish and very economical. Painted steel is used successfully for many applications, including industrial equipment with electrical enclosures. Unless the proper paint and application procedures are selected, corrosion problems may develop directly from the paint, as the following incident will illustrate. A few years ago, a large electrical control enclosure [30 x 72 x 18 in. (76 x 183 x 46 cm)] was supplied to a customer with the control wiring and hardware mounted inside, which included a number of cadmium plated components. The enclosure had been painted inside with a fast drying, vinyl alkyd white enamel shortly before assembly. Since it was known that the completed unit would probably be stored at the customer's plant site for some time before installation, elaborate procedures were followed to retard or prevent degradation of any part of the system

  17. Use of Local Dynamic Electricity Prices for Indirect Control of DER Power Units

    DEFF Research Database (Denmark)

    Nørgård, Per Bromand; Isleifsson, Fridrik Rafn

    2013-01-01

    the grid voltage. The algorithms generating the local prices are dynamically adjusted according to the actual realised responses to the dynamic prices. Results are presented from an adapted version of the control principle implemented and tested in DTUs experimental research power system, SYSLAB, including...... wind power, solar power, flexible load and electrical storage. The local power price generation is based on the actual Nord Pool DK2 Spot prices on hourly basis as the quasi-stationary global electricity price, and the local SYSLAB's power exchange with the national grid as basis for the dynamic price...... system. A challenge is to find a cheap, simple and robust way to requests the proper power regulation by the DER power units. The use of broadcasted, dynamic power prices and volunteer responses is one option. The paper presents a proposal for and an illustration of advanced generation of local, dynamic...

  18. Model-based investigation of the electricity market. Unit commitment and power plant investments

    International Nuclear Information System (INIS)

    Sun, Ninghong

    2013-01-01

    The German Federal Government published its energy concept in September 2010 with a description of the road into the era of renewable energies. Therefore, the future renewable energy installed in Germany is expected to consist mostly of wind and solar, which are subject to intermittency of supply and significant fluctuations. The growing portion of energy generation by fluctuating sources is turning to a big challenge for the power plant unit commitment and the investment decisions as well. In this thesis, a fundamental electricity market model with combined modeling of these two aspects is developed. This model is subsequently applied to the German electricity market to investigate what kind of power plant investments are indispensable, considering the steadily increasing portion of energy generation from fluctuating sources, to ensure a reliable energy supply in a cost-effective way in the future. In addition, current energy policy in Germany regarding the use of renewable energy and nuclear energy is analyzed.

  19. Exposure to electromagnetic fields aboard high-speed electric multiple unit trains.

    Science.gov (United States)

    Niu, D; Zhu, F; Qiu, R; Niu, Q

    2016-01-01

    High-speed electric multiple unit (EMU) trains generate high-frequency electric fields, low-frequency magnetic fields, and high-frequency wideband electromagnetic emissions when running. Potential human health concerns arise because the electromagnetic disturbances are transmitted mainly into the car body from windows, and from there to passengers and train staff. The transmission amount and amplitude distribution characteristics that dominate electromagnetic field emission need to be studied, and the exposure level of electromagnetic field emission to humans should be measured. We conducted a series of tests of the on board electromagnetic field distribution on several high-speed railway lines. While results showed that exposure was within permitted levels, the possibility of long-term health effects should be investigated.

  20. Alteration in reactor installation (addition of Unit 2) in Shimane Nuclear Power Station, Chugoku Electric Power Co., Inc. (inquiry)

    International Nuclear Information System (INIS)

    1983-01-01

    An inquiry was made by the Ministry of International Trade and Industry to Nuclear Safety Commission on the addition of Unit 2 in Shimane Nuclear Power Station of The Chugoku Electric Power Co., Inc., concerning the technical capability of Chugoku Electric Power Co., Inc., and the plant safety. The NSC requested the Committee on Examination of Reactor Safety to make a deliberation on this subject. Both the technical capability and the safety of Unit 1 were already confirmed by MITI. Unit 2 to be newly added in the Shimane Nuclear Power Station is a BWR power plant with electric output of 820 MW. The examination made by MITI is described: the technical capability of Chugoku Electric Power Co., Inc., the safety of Unit 2 about its siting, reactor proper, reactor cooling system, radioactive waste management, etc. (J.P.N.)

  1. A novel Generalized State-Space Averaging (GSSA) model for advanced aircraft electric power systems

    International Nuclear Information System (INIS)

    Ebrahimi, Hadi; El-Kishky, Hassan

    2015-01-01

    Highlights: • A study model is developed for aircraft electric power systems. • A novel GSSA model is developed for the interconnected power grid. • The system’s dynamics are characterized under various conditions. • The averaged results are compared and verified with the actual model. • The obtained measured values are validated with available aircraft standards. - Abstract: The growing complexity of Advanced Aircraft Electric Power Systems (AAEPS) has made conventional state-space averaging models inadequate for systems analysis and characterization. This paper presents a novel Generalized State-Space Averaging (GSSA) model for the system analysis, control and characterization of AAEPS. The primary objective of this paper is to introduce a mathematically elegant and computationally simple model to copy the AAEPS behavior at the critical nodes of the electric grid. Also, to reduce some or all of the drawbacks (complexity, cost, simulation time…, etc) associated with sensor-based monitoring and computer aided design software simulations popularly used for AAEPS characterization. It is shown in this paper that the GSSA approach overcomes the limitations of the conventional state-space averaging method, which fails to predict the behavior of AC signals in a circuit analysis. Unlike conventional averaging method, the GSSA model presented in this paper includes both DC and AC components. This would capture the key dynamic and steady-state characteristics of the aircraft electric systems. The developed model is then examined for the aircraft system’s visualization and accuracy of computation under different loading scenarios. Through several case studies, the applicability and effectiveness of the GSSA method is verified by comparing to the actual real-time simulation model obtained from Powersim 9 (PSIM9) software environment. The simulations results represent voltage, current and load power at the major nodes of the AAEPS. It has been demonstrated that

  2. Construction of Shika Nuclear Power Station Unit No.2 of the Hokuriku Electric Power Co., Inc

    International Nuclear Information System (INIS)

    Yamanari, Shozo; Miyahara, Ryohei; Umezawa, Takeshi; Teshiba, Ichiro

    2006-01-01

    Construction of the Shika Nuclear Power Station Unit No.2 of the Hokuriku Electric Power Co., Inc. (advanced boiling-water reactor; output: 1.358 mega watts) was begun in August 1999 and it will resume commercial operation in March 2006 as scheduled. Hitachi contributed effectually toward realizing the project with supply of a complete set of the advanced nuclear reactor and turbine-generator system with the latest design and construction technology in harmony. Large-scale modular structures for installation and a computer-aided engineering system for work procedure and schedule management were applied with the utmost priority placed on work efficiency, safety and quality assurance. (T.Tanaka)

  3. Group cohesion and social support of the nurses in a special unit and a general unit in Korea.

    Science.gov (United States)

    Ko, Yu Kyung

    2011-07-01

    To identify the degree of group cohesion and social support of nurses in special and general units in hospitals in Korea, and to compare group cohesion and social support between the two groups. The level of commitment nurses have to their organizations has been shown to correlate with work group cohesion and social support. The participants were 1751 nurses who were working in Korean hospitals. Data were collected using a structured questionnaire and were analysed using SAS. The statistical methods included: descriptive statistics, t-test, anova and Pearson's correlation coefficients. Group cohesion of nurses on special wards was significantly higher than for nurses on general wards. No significant difference was found between types of units in terms of social support. The degree of group cohesion was significantly different in terms of the respondents' clinical experience, position, religion, job satisfaction, number of supportive superiors and number of supportive peers. A statistically significant correlation was found between group cohesion scores and degree of social support. Hospital management can accomplish their goals more effectively through knowledge of the level of group cohesion, superior support and peer support for nursing staff in accordance with unit specialty. © 2011 The Author. Journal compilation © 2011 Blackwell Publishing Ltd.

  4. Statement to the fifty-fifth session of the United Nations General Assembly

    International Nuclear Information System (INIS)

    ElBaradei, M.

    2000-01-01

    In his statement to the fifty-fifth session of the United Nations General Assembly, the Director General of the IAEA briefly presented the three fundamental functions of the IAEA, namely: its role as a catalyst for the development and transfer of peaceful nuclear technologies, the efforts to prevent the proliferation of nuclear weapons and move towards nuclear disarmament, and the work to build and maintain a global nuclear safety regime

  5. Estimated Value of Service Reliability for Electric Utility Customers in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, M.J.; Mercurio, Matthew; Schellenberg, Josh

    2009-06-01

    Information on the value of reliable electricity service can be used to assess the economic efficiency of investments in generation, transmission and distribution systems, to strategically target investments to customer segments that receive the most benefit from system improvements, and to numerically quantify the risk associated with different operating, planning and investment strategies. This paper summarizes research designed to provide estimates of the value of service reliability for electricity customers in the US. These estimates were obtained by analyzing the results from 28 customer value of service reliability studies conducted by 10 major US electric utilities over the 16 year period from 1989 to 2005. Because these studies used nearly identical interruption cost estimation or willingness-to-pay/accept methods it was possible to integrate their results into a single meta-database describing the value of electric service reliability observed in all of them. Once the datasets from the various studies were combined, a two-part regression model was used to estimate customer damage functions that can be generally applied to calculate customer interruption costs per event by season, time of day, day of week, and geographical regions within the US for industrial, commercial, and residential customers. Estimated interruption costs for different types of customers and of different duration are provided. Finally, additional research and development designed to expand the usefulness of this powerful database and analysis are suggested.

  6. Nuclear Electricity in the United States : Providing Energy For The Nation's Security and Well-Being

    International Nuclear Information System (INIS)

    Finger, Harold B.

    1988-01-01

    Nuclear energy in the United States has made major contributions since the small Shippingport prototype power plant began operating in 1957. Recent legislative and regulatory actions, as well as research an development, are indicating that additional nuclear capacity can be available in the years ahead. These actions reflect the public's recognition of the importance of nuclear energy. In addition, recent regulatory actions are reaffirming the health and safety of our current nuclear plants, as well as of those being completed. The performance of our current plants is being improved through the conscious dedication of the entire industry to excellence. There is increasing discussion in the United States of the importance of advanced reactor concepts development. The next generation of nuclear plants is already being ordered outside of the United States for example, here in Korea, in Japan, in the United Kingdom and those plants all use light water reactors. We are pleased that U. S. companies are working with you on these new plants. That continues to mean that we never let up on our drive for excellence. Excellence in operations must continue to be the conscious target of all operators. Excellence in communications to the public of the need for electrical capacity, of the benefits of nuclear energy, and of the excellence being achieved in operations is also essential. And excellence in communication to decision makers at all levels of government is also required to assure that sound legalisation and regulation is established and implemented

  7. General Stroke Management In Stroke Unit: Guidelines Of Turkish Society Of Cerebrovascular Diseases – 2015

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Topçuoğlu

    2015-08-01

    Full Text Available In this section, in the light of evidence-based data concerning essentiality that the stoke patients should be treated in A stroke unit and related centers, a brief and current information about general stroke treatment of patients with stroke during acute phase will be offered.

  8. THE POSITION BUDGETS OF ADMINISTRATIVE AND TERRITORIAL UNITS IN GENERAL CONSOLIDATED BUDGET

    Directory of Open Access Journals (Sweden)

    CHIRCULESCU MARIA FELICIA

    2017-12-01

    Full Text Available The budget is a tool of territorial administrative units of financial and budgetary policy in which the state intervenes in the economy at the local level, having a major impact on general government.Through the decentralization processes that are increasingly debated and applied, the paper aims to highlight the importance of the territorial administrative unit budgets in the consolidated budget in Romania.Thus, the work comprises both theoretical notions concerning the presentation of the consolidated state budget and the budget of the territorial administrative units. The relevance of the work lies in the importance of general government in the regulation of macroeconomic balances by sizing or macroeconomic imbalances, with modern methods that analyze the possibilities and effects of new types of deficits or surpluses in the public sector.

  9. Brayton Power Conversion Unit Tested: Provides a Path to Future High-Power Electric Propulsion Missions

    Science.gov (United States)

    Mason, Lee S.

    2003-01-01

    Closed-Brayton-cycle conversion technology has been identified as an excellent candidate for nuclear electric propulsion (NEP) power conversion systems. Advantages include high efficiency, long life, and high power density for power levels from about 10 kWe to 1 MWe, and beyond. An additional benefit for Brayton is the potential for the alternator to deliver very high voltage as required by the electric thrusters, minimizing the mass and power losses associated with the power management and distribution (PMAD). To accelerate Brayton technology development for NEP, the NASA Glenn Research Center is developing a low-power NEP power systems testbed that utilizes an existing 2- kWe Brayton power conversion unit (PCU) from previous solar dynamic technology efforts. The PCU includes a turboalternator, a recuperator, and a gas cooler connected by gas ducts. The rotating assembly is supported by gas foil bearings and consists of a turbine, a compressor, a thrust rotor, and an alternator on a single shaft. The alternator produces alternating-current power that is rectified to 120-V direct-current power by the PMAD unit. The NEP power systems testbed will be utilized to conduct future investigations of operational control methods, high-voltage PMAD, electric thruster interactions, and advanced heat rejection techniques. The PCU was tested in Glenn s Vacuum Facility 6. The Brayton PCU was modified from its original solar dynamic configuration by the removal of the heat receiver and retrofitting of the electrical resistance gas heater to simulate the thermal input of a steady-state nuclear source. Then, the Brayton PCU was installed in the 3-m test port of Vacuum Facility 6, as shown. A series of tests were performed between June and August of 2002 that resulted in a total PCU operational time of about 24 hr. An initial test sequence on June 17 determined that the reconfigured unit was fully operational. Ensuing tests provided the operational data needed to characterize PCU

  10. Ultimate Electrical Means for Severe Accident and Multi Unit Event Management

    International Nuclear Information System (INIS)

    Guisez, Xavier

    2015-01-01

    Following the Multi Unit Severe Accident that occurred at Fukushima as a result of the tsunami on 11 March 2011, the European Council decided to submit its Nuclear Power Plants to a Stress Test. In Belgium, this Stress Test, named BEST (Belgian Stress Test), was successfully concluded at the end of 2011. Nevertheless, Electrabel decided, in agreement with the Authorities, to start a beyond design basis action plan, with the goal to mitigate the consequences of a Beyond Design Basis Accident and a Multi Unit Event. Consequently, this has led to an improvement of the robustness of its Nuclear Power Plants. Considering the importance of electrical power supply to a nuclear power plant, a significant part of this action plan consisted of setting up a mobile, 'plug and play' method for the electrical power supply to some major safety systems. In order to install this ultimate power supply, three factors were retained as essential. First, important reactor monitoring instrumentation is preserved. Second, core cooling is provided at all times. Finally, systems are easily made operational within a very short delay of time. During normal operation and Design Basis Events, core cooling is provided by High Voltage equipment. However, during high stress circumstances, it is too complex to realize connections on this equipment. Therefore, analysis was performed to realize core cooling with, easier to handle, Low Voltage equipment. These systems are powered by several GenSets, especially designed and manufactured for this application. The outcome of this project are easy to use, ultimate means, that supply electric power to important safety systems in order to drastically reduce the risk of core damage, during a beyond design basis event. Additionally, for all ultimate means, procedures and training modules were developed for the operators. (authors)

  11. Attempt to generalize fractional-order electric elements to complex-order ones

    Science.gov (United States)

    Si, Gangquan; Diao, Lijie; Zhu, Jianwei; Lei, Yuhang; Zhang, Yanbin

    2017-06-01

    The complex derivative {D}α +/- {{j}β }, with α, β \\in R+ is a generalization of the concept of integer derivative, where α=1, β=0. Fractional-order electric elements and circuits are becoming more and more attractive. In this paper, the complex-order electric elements concept is proposed for the first time, and the complex-order elements are modeled and analyzed. Some interesting phenomena are found that the real part of the order affects the phase of output signal, and the imaginary part affects the amplitude for both the complex-order capacitor and complex-order memristor. More interesting is that the complex-order capacitor can do well at the time of fitting electrochemistry impedance spectra. The complex-order memristor is also analyzed. The area inside the hysteresis loops increases with the increasing of the imaginary part of the order and decreases with the increasing of the real part. Some complex case of complex-order memristors hysteresis loops are analyzed at last, whose loop has touching points beyond the origin of the coordinate system.

  12. Spatial generalized linear mixed models of electric power outages due to hurricanes and ice storms

    International Nuclear Information System (INIS)

    Liu Haibin; Davidson, Rachel A.; Apanasovich, Tatiyana V.

    2008-01-01

    This paper presents new statistical models that predict the number of hurricane- and ice storm-related electric power outages likely to occur in each 3 kmx3 km grid cell in a region. The models are based on a large database of recent outages experienced by three major East Coast power companies in six hurricanes and eight ice storms. A spatial generalized linear mixed modeling (GLMM) approach was used in which spatial correlation is incorporated through random effects. Models were fitted using a composite likelihood approach and the covariance matrix was estimated empirically. A simulation study was conducted to test the model estimation procedure, and model training, validation, and testing were done to select the best models and assess their predictive power. The final hurricane model includes number of protective devices, maximum gust wind speed, hurricane indicator, and company indicator covariates. The final ice storm model includes number of protective devices, ice thickness, and ice storm indicator covariates. The models should be useful for power companies as they plan for future storms. The statistical modeling approach offers a new way to assess the reliability of electric power and other infrastructure systems in extreme events

  13. Simulation of the preliminary General Electric SP-100 space reactor concept using the ATHENA computer code

    International Nuclear Information System (INIS)

    Fletcher, C.D.

    1986-01-01

    The capability to perform thermal-hydraulic analyses of a space reactor using the ATHENA computer code is demonstrated. The fast reactor, liquid-lithium coolant loops, and lithium-filled heat pipes of the preliminary General electric SP-100 design were modeled with ATHENA. Two demonstration transient calculations were performed simulating accident conditions. Calculated results are available for display using the Nuclear Plant Analyzer color graphics analysis tool in addition to traditional plots. ATHENA-calculated results appear reasonable, both for steady state full power conditions, and for the two transients. This analysis represents the first known transient thermal-hydraulic simulation using an integral space reactor system model incorporating heat pipes. 6 refs., 17 figs., 1 tab

  14. Potential criticality accident at the General Electric Nuclear Fuel and Component Manufacturing Facility, May 29, 1991

    International Nuclear Information System (INIS)

    1991-08-01

    At the General Electric Nuclear Fuel and Component Manufacturing facility, located near Wilmington, North Carolina, on May 28 and 29, 1991, approximately 150 kilograms of uranium were inadvertently transferred from safe process tanks to an unsafe tank located at the waste treatment facility, thus creating the potential for a localized criticality safety problem. The excess uranium was ultimately safely recovered when the tank contents were centrifuged to remove the uranium-bearing material. Subsequently, the US Nuclear Regulatory Commission dispatched an Incident Investigation Team to determine what happened, to identify probable causes, and to make appropriate findings and conclusions. This report describes the incident, the methodology used by the team in its investigation, and presents the team's findings and conclusions. 48 figs., 8 tabs

  15. Vacuum education courses at the General Electric Company's Neutron Devices Department, St. Petersburg, Florida

    International Nuclear Information System (INIS)

    Provo, J.L.; Brown, W.C.

    1978-01-01

    Vacuum Technology has, from the beginning, played a key role in the production of the Department's products at the General Electric Company's Neutron Devices Department (GEND). Early recognition was given to the need for vacuum education and training for producing and maintaining vacuums to meet departmental objectives. The vacuum courses taught at GEND are described. These include basic Vacuum Technology, Advanced Vacuum Technology, and specialized vacuum related courses. Course offering rationale, outlines of subject matter covered and criteria for measuring effectiveness will be presented for each course. Such vacuum technology related courses have resulted in improved GEND product quality and in reducing losses and production cost. At the same time, these courses have given participating employees career motivation for fulfilling more challenging vacuum technology job related positions and have enabled them to achieve upward mobility in the Department's work force

  16. General Equilibrium Analysis of Electricity Market Liberalization in Singapore: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Fenglong XIAO

    2011-12-01

    Full Text Available The liberalization in electricity market in Singapore has being undertaken for more than 15 years. This paper evaluates the influence of competition policies by computable general equilibrium (CGE model. Instead of the direct measurement of the impact of competition policy, the benefit of liberalization is reflected by the simulation of a hypothetical regulatory condition. Comparing to the regulatory scenario, simulation result implies the current liberalization raises GDP and exchange rate significantly, but also leaves the tradeoff between higher national income and lower consumer welfare to government. If such choice of economic policy is necessary for political demand, a formal legal framework is required to enforce the restoration of the economy from regulatory restrictions.

  17. Use and benefit summary of General Electric Company thermocase insulated tubulars for steam enhanced oil recovery

    Energy Technology Data Exchange (ETDEWEB)

    Traynor, B.V. Jr.; Hawley, J.R.; Marziani, V.J.; Prevost, W.M.

    1982-01-01

    General Electric Co.'s (GE) first well-bore insulation in 1969 resulted from the industry's need to produce hot oil on Alaska's North Slope without damaging the permafrost. In the past 3 yr, over 500,000 linear ft of GE's Thermocase has been sold. Thermocase tubulars are in use in California, Wyoming, Texas, Canada, Venezuela, and the USSR. Thermocase insulated tubulars are being used in a wide range of reservoirs under a variety of completion designs. This study discusses field experience, thermal completion benefits afforded by Thermocase tubulars, a quantified economic evaluation in a 1000-ft application, as well as GE's product verification, test and rigid quality control program.

  18. Linear electrical circuits. Definitions - General theorems; Circuits electriques lineaires. Definitions - Theoremes generaux

    Energy Technology Data Exchange (ETDEWEB)

    Escane, J.M. [Ecole Superieure d' Electricite, 91 - Gif-sur-Yvette (France)

    2005-04-01

    The first part of this article defines the different elements of an electrical network and the models to represent them. Each model involves the current and the voltage as a function of time. Models involving time functions are simple but their use is not always easy. The Laplace transformation leads to a more convenient form where the variable is no more directly the time. This transformation leads also to the notion of transfer function which is the object of the second part. The third part aims at defining the fundamental operation rules of linear networks, commonly named 'general theorems': linearity principle and superimposition theorem, duality principle, Thevenin theorem, Norton theorem, Millman theorem, triangle-star and star-triangle transformations. These theorems allow to study complex power networks and to simplify the calculations. They are based on hypotheses, the first one is that all networks considered in this article are linear. (J.S.)

  19. 76 FR 17447 - Penske Logistics LLC a Subsidiary of General Electric/Penske Corporation Including On-Site Leased...

    Science.gov (United States)

    2011-03-29

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,897] Penske Logistics LLC a Subsidiary of General Electric/Penske Corporation Including On-Site Leased Workers From Kelly Temporary... (TAA) applicable to workers and former workers of Penske Logistics LLC, a subsidiary of General...

  20. 28 CFR 0.109 - Implementation of the Treaty of Friendship and General Relations Between the United States and...

    Science.gov (United States)

    2010-07-01

    ... Friendship and General Relations Between the United States and Spain. 0.109 Section 0.109 Judicial... Service § 0.109 Implementation of the Treaty of Friendship and General Relations Between the United States... States within the meaning of Article XXIV of the Treaty of Friendship and General Relations Between the...

  1. DRUG MANAGEMENT REVIEWS IN DISTRICT DRUG MANAGEMENT UNIT AND GENERAL HOSPITAL

    Directory of Open Access Journals (Sweden)

    Max Joseph Herman

    2009-12-01

    Full Text Available Drug is one of the essential elements in healthcare that should be effectively and efficiently managed. Following thedecentralization in 2001 in Indonesia, drug management has changed in district drug management units and also in District General Hospitals. Certainly this condition influences the sustainability of drug access in primary health care such as in Community Health Center and District General Hospital, especially in drug financing policy. A cross sectional descriptive study to obtain information on drug management in public healthcare in district had been carried out between July and December 2006 in 10 District Public Drug Management Units from 10 district health offices and 9 district general hospitals as samples. Data were collected by interviewing heads of Drug Section in District Health Offices and heads of Hospital Pharmacies using structured questionnaires and observing drug storage in District Drug Management Units, Community Health Centers, and Hospital Pharmacies. Results of the study show that drug planning in District Health Offices and General Hospitals did not meet the basic real need in some districts nor District Hospitals. The minimum health service standards had no been achieved yet. Furthermore, drug procurement, storage and recording as well as reporting was not good enough either, such as shown by the existence of expired drugs. Lead time for drug delivery to community health centers in some districts was longer than the average of lead time in the past 3 years.

  2. Teaching Emotional Intelligence to Intensive Care Unit Nurses and their General Health: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    F Sharif

    2013-07-01

    Full Text Available Background: Emotion and how people manage it is an important part of personality that would immensely affect their health. Investigations showed that emotional intelligence is significantly related to and can predict psychological health. Objective: To determine the effect of teaching emotional intelligence to intensive care unit nurses on their general health. Methods: This randomized clinical trial (registered as IRCT201208022812N9 was conducted on 52 of 200 in intensive care unit nurses affiliated to Shiraz University of Medical Sciences. They were recruited through purposeful convenience sampling and then randomly categorized into two groups. The intervention group members were trained in emotional intelligence. Bar-on emotional intelligence and Goldberg's general health questionnaires were administered to each participant before, immediately after, and one month after the intervention. Results: While the mean score of general health for the intervention group decreased from 25.4 before the intervention, to 18.1 immediately after the intervention and to 14.6 one month later, for the control group, it increased from 22.0, to 24.2 and to 26.5, respectively (p<0.001. Conclusion: Teaching emotional intelligence improved the general health of intensive care unit nurses.

  3. Meeting electricity demand in the United Kingdom in the eighties and beyond

    International Nuclear Information System (INIS)

    Lomer, D.R.

    The paper will describe the present system, its structure, the installed generating plant and fuel requirements. It will then discuss plants for the medium term, in general for the period 1980-1990. Future developments into the longer term (up to 2000) will be presented in broad terms setting out general views by the Department of Energy on all fuel demands and supplies, also expected electricity requirement, also the CEGB's views. A brief statement of possible coal, oil and gas supplies for the UK will be made. The basis of the agreed policy between Government and Industry to build 15 GW of nuclear plant in the next 10 years will be described. A view of the prospects for alternative energy supplies will be set out. The uncertainty of planning in the long term will be stressed and possible contingency plans described. (orig.) [de

  4. Implementation of the rapid cross section adjustment approach at General Electric

    International Nuclear Information System (INIS)

    Cowan, C.L.; Kujawski, E.; Protsik, R.

    1978-01-01

    The General Electric rapid cross section adjustment approach was developed to use the shielding factor method for formulating multigroup cross sections. In this approach, space- and composition-dependent cross sections for a particular reactor or shield design are prepared from a generalized cross section library by the use of resonance self-shielding factors, and by the adjustment of elastic scattering cross sections for the local neutron flux spectra. The principal tool in the cross section adjustment package is the data processing code TDOWN. This code was specified to give the user a high degree of flexibility in the analysis of advanced reactor designs. Of particular interest in the analysis of critical experiments is the ability to carry out cell heterogeneity self-shielding calculations using a multiregion equivalence relationship, and the homogenization of the cross sections over the specified cell with the flux weighting obtained from transport theory calculations. Extensive testing of the rapid cross section adjustment approach, including comparisons with Monte Carlo methods, indicated that this approach can be utilized with a high degree of confidence in the design analysis of complex fast reactor systems. 2 figures, 1 table

  5. The paradoxes of patenting at General Electric: Isador Ladoff's journey from Siberian exile to the heart of corporate capitalism.

    Science.gov (United States)

    Miller, David Philip

    2011-12-01

    Isador Ladoff (1857-1918) worked briefly in the General Electric Company Research Laboratory, from 1901 to 1903. Since he was not employed to invent, Ladoff maintained that he, not the company, owned his invention of a new arc lamp electrode, eventually winning his case on appeal in 1911. The conduct and course of this patent litigation are examined in the light of Ladoff's remarkable life as a prisoner of the czar in Siberia before his escape to the United States in 1891 and as a socialist activist and writer thereafter. In showing that Ladoff's socialist principles activated his struggle with GE, the essay brings out the ironies of his defense of individualism against the incipient socialism of the laboratory supposedly espoused by officials of the company. The case is interesting in relation to the shift from the ideology, and the reality, of heroic individual invention to that of corporate invention in U.S. industrial research. That shift in turn was a crucial landmark in the longer history of the place of science in negotiation and contest about the relationship between creativity and intellectual property.

  6. Load Frequency Control in Isolated Micro-Grids with Electrical Vehicles Based on Multivariable Generalized Predictive Theory

    Directory of Open Access Journals (Sweden)

    Jun Yang

    2015-03-01

    Full Text Available In power systems, although the inertia energy in power sources can partly cover power unbalances caused by load disturbance or renewable energy fluctuation, it is still hard to maintain the frequency deviation within acceptable ranges. However, with the vehicle-to-grid (V2G technique, electric vehicles (EVs can act as mobile energy storage units, which could be a solution for load frequency control (LFC in an isolated grid. In this paper, a LFC model of an isolated micro-grid with EVs, distributed generations and their constraints is developed. In addition, a controller based on multivariable generalized predictive control (MGPC theory is proposed for LFC in the isolated micro-grid, where EVs and diesel generator (DG are coordinated to achieve a satisfied performance on load frequency. A benchmark isolated micro-grid with EVs, DG, and wind farm is modeled in the Matlab/Simulink environment to demonstrate the effectiveness of the proposed method. Simulation results demonstrate that with MGPC, the energy stored in EVs can be managed intelligently according to LFC requirement. This improves the system frequency stability with complex operation situations including the random renewable energy resource and the continuous load disturbances.

  7. Real-time radar signal processing using GPGPU (general-purpose graphic processing unit)

    Science.gov (United States)

    Kong, Fanxing; Zhang, Yan Rockee; Cai, Jingxiao; Palmer, Robert D.

    2016-05-01

    This study introduces a practical approach to develop real-time signal processing chain for general phased array radar on NVIDIA GPUs(Graphical Processing Units) using CUDA (Compute Unified Device Architecture) libraries such as cuBlas and cuFFT, which are adopted from open source libraries and optimized for the NVIDIA GPUs. The processed results are rigorously verified against those from the CPUs. Performance benchmarked in computation time with various input data cube sizes are compared across GPUs and CPUs. Through the analysis, it will be demonstrated that GPGPUs (General Purpose GPU) real-time processing of the array radar data is possible with relatively low-cost commercial GPUs.

  8. Comparisons of auction mechanisms in a multiple unit setting: A consideration for restructuring electric power markets

    Science.gov (United States)

    Bernard, John Charles

    The objective of this study was to compare the performance of five single sided auctions that could be used in restructured electric power markets across different market sizes in a multiple unit setting. Auction selection would profoundly influence an industry over $200 billion in size in the United States, and the consequences of implementing an inappropriate mechanism would be great. Experimental methods were selected to analyze the auctions. Two rounds of experiments were conducted, the first testing the sealed offer last accepted offer (LAO) and first rejected offer (FRO), and the clock English (ENG) and sealed offer English (SOE) in markets of sizes two and six. The FRO, SOE, and ENG used the same pricing rule. Second round testing was on the LAO, FRO, and the nonuniform price multiple unit Vickrey (MUV) in markets of sizes two, four, and six. Experiments lasted 23 and 75 periods for rounds 1 and 2 respectively. Analysis of variance and contrast analysis were used to examine the data. The four performance measures used were price, efficiency, profits per unit, and supply revelation. Five basic principles were also assessed: no sales at losses, all low cost capacity should be offered and sold, no high cost capacity should sell, and the market should clear. It was expected group size and auction type would affect performance. For all performance measures, group size was a significant variable, with smaller groups showing poorer performance. Auction type was significant only for the efficiency performance measure, where clock auctions outperformed the others. Clock auctions also proved superior for the first four principles. The FRO performed poorly in almost all situations, and should not be a preferred mechanism in any market. The ENG was highly efficient, but expensive for the buyer. The SOE appeared superior to the FRO and ENG. The clock improves efficiency over the FRO while less information kept prices under the ENG. The MUV was superior in revealing costs

  9. Method and apparatus for preventing inadvertent criticality in a nuclear fueled electric power generating unit

    International Nuclear Information System (INIS)

    Tuley, C.R.; Bauman, D.A.; Neuner, J.A.; Feilchenfeld, M.M.; Greenberg, L.

    1984-01-01

    An inadvertent approach to criticality in a nuclear fueled electric power generating unit is detected and an alarm is generated through on-line monitoring of the neutron flux. The difficulties of accurately measuring the low levels of neutron flux in a subcritical reactor are overcome by the use of a microcomputer which continuously generates average flux count rate signals for incremental time periods from thousands of samples taken during each such period and which serially stores the average flux count rate signals for a preselected time interval. At the end of each incremental time period, the microcomputer compares the latest average flux count rate signal with the oldest, and preferably each of the intervening stored values, and if it exceeds any of them by at least a preselected multiplication factor, an alarm is generated. (author)

  10. Optimizing the Shunting Schedule of Electric Multiple Units Depot Using an Enhanced Particle Swarm Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Jiaxi Wang

    2016-01-01

    Full Text Available The shunting schedule of electric multiple units depot (SSED is one of the essential plans for high-speed train maintenance activities. This paper presents a 0-1 programming model to address the problem of determining an optimal SSED through automatic computing. The objective of the model is to minimize the number of shunting movements and the constraints include track occupation conflicts, shunting routes conflicts, time durations of maintenance processes, and shunting running time. An enhanced particle swarm optimization (EPSO algorithm is proposed to solve the optimization problem. Finally, an empirical study from Shanghai South EMU Depot is carried out to illustrate the model and EPSO algorithm. The optimization results indicate that the proposed method is valid for the SSED problem and that the EPSO algorithm outperforms the traditional PSO algorithm on the aspect of optimality.

  11. Optimizing the Shunting Schedule of Electric Multiple Units Depot Using an Enhanced Particle Swarm Optimization Algorithm

    Science.gov (United States)

    Jin, Junchen

    2016-01-01

    The shunting schedule of electric multiple units depot (SSED) is one of the essential plans for high-speed train maintenance activities. This paper presents a 0-1 programming model to address the problem of determining an optimal SSED through automatic computing. The objective of the model is to minimize the number of shunting movements and the constraints include track occupation conflicts, shunting routes conflicts, time durations of maintenance processes, and shunting running time. An enhanced particle swarm optimization (EPSO) algorithm is proposed to solve the optimization problem. Finally, an empirical study from Shanghai South EMU Depot is carried out to illustrate the model and EPSO algorithm. The optimization results indicate that the proposed method is valid for the SSED problem and that the EPSO algorithm outperforms the traditional PSO algorithm on the aspect of optimality. PMID:27436998

  12. Risk factors associated with bus accident severity in the United States: A generalized ordered logit model

    DEFF Research Database (Denmark)

    Kaplan, Sigal; Prato, Carlo Giacomo

    2012-01-01

    of 2011. Method: The current study investigates the underlying risk factors of bus accident severity in the United States by estimating a generalized ordered logit model. Data for the analysis are retrieved from the General Estimates System (GES) database for the years 2005–2009. Results: Results show...... that accident severity increases: (i) for young bus drivers under the age of 25; (ii) for drivers beyond the age of 55, and most prominently for drivers over 65 years old; (iii) for female drivers; (iv) for very high (over 65 mph) and very low (under 20 mph) speed limits; (v) at intersections; (vi) because......Introduction: Recent years have witnessed a growing interest in improving bus safety operations worldwide. While in the United States buses are considered relatively safe, the number of bus accidents is far from being negligible, triggering the introduction of the Motor-coach Enhanced Safety Act...

  13. Prediction of chronic critical illness in a general intensive care unit

    Directory of Open Access Journals (Sweden)

    Sérgio H. Loss

    2013-06-01

    Full Text Available OBJECTIVE: To assess the incidence, costs, and mortality associated with chronic critical illness (CCI, and to identify clinical predictors of CCI in a general intensive care unit. METHODS: This was a prospective observational cohort study. All patients receiving supportive treatment for over 20 days were considered chronically critically ill and eligible for the study. After applying the exclusion criteria, 453 patients were analyzed. RESULTS: There was an 11% incidence of CCI. Total length of hospital stay, costs, and mortality were significantly higher among patients with CCI. Mechanical ventilation, sepsis, Glasgow score < 15, inadequate calorie intake, and higher body mass index were independent predictors for cci in the multivariate logistic regression model. CONCLUSIONS: CCI affects a distinctive population in intensive care units with higher mortality, costs, and prolonged hospitalization. Factors identifiable at the time of admission or during the first week in the intensive care unit can be used to predict CCI.

  14. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation.

    Science.gov (United States)

    McGrath, Susan P; Taenzer, Andreas H; Karon, Nancy; Blike, George

    2016-07-01

    The growing number of monitoring devices, combined with suboptimal patient monitoring and alarm management strategies, has increased "alarm fatigue," which have led to serious consequences. Most reported alarm man- agement approaches have focused on the critical care setting. Since 2007 Dartmouth-Hitchcock (Lebanon, New Hamp- shire) has developed a generalizable and effective design, implementation, and performance evaluation approach to alarm systems for continuous monitoring in general care settings (that is, patient surveillance monitoring). In late 2007, a patient surveillance monitoring system was piloted on the basis of a structured design and implementation approach in a 36-bed orthopedics unit. Beginning in early 2009, it was expanded to cover more than 200 inpatient beds in all medicine and surgical units, except for psychiatry and labor and delivery. Improvements in clinical outcomes (reduction of unplanned transfers by 50% and reduction of rescue events by more than 60% in 2008) and approximately two alarms per patient per 12-hour nursing shift in the original pilot unit have been sustained across most D-H general care units in spite of increasing patient acuity and unit occupancy. Sample analysis of pager notifications indicates that more than 85% of all alarm conditions are resolved within 30 seconds and that more than 99% are resolved before escalation is triggered. The D-H surveillance monitoring system employs several important, generalizable features to manage alarms in a general care setting: alarm delays, static thresholds set appropriately for the prevalence of events in this setting, directed alarm annunciation, and policy-driven customization of thresholds to allow clinicians to respond to needs of individual patients. The systematic approach to design, implementation, and performance management has been key to the success of the system.

  15. Climate Change Impacts on Rivers and Implications for Electricity Generation in the United States

    Science.gov (United States)

    Miara, A.; Vorosmarty, C. J.; Macknick, J.; Corsi, F.; Cohen, S. M.; Tidwell, V. C.; Newmark, R. L.; Prousevitch, A.

    2015-12-01

    The contemporary power sector in the United States is heavily reliant on water resources to provide cooling water for thermoelectric generation. Efficient thermoelectric plant operations require large volumes of water at sufficiently cool temperatures for their cooling process. The total amount of water that is withdrawn or consumed for cooling and any potential declines in efficiencies are determined by the sector's fuel mix and cooling technologies. As such, the impact of climate change, and the extent of impact, on the power sector is shaped by the choice of electricity generation technologies that will be built over the coming decades. In this study, we model potential changes in river discharge and temperature in the contiguous US under a set of climate scenarios to year 2050 using the Water Balance Model-Thermoelectric Power and Thermal Pollution Model (WBM-TP2M). Together, these models quantify, in high-resolution (3-min), river temperatures, discharge and power plant efficiency losses associated with changes in available cooling water that incorporates climate, hydrology, river network dynamics and multi-plant impacts, on both single power plant and regional scales. Results are used to assess the aptness and vulnerability of contemporary and alternative electricity generation pathways to changes in climate and water availability for cooling purposes, and the concomitant impacts on power plant operating efficiencies. We assess the potential impacts by comparing six regions (Northeast, Southeast, Midwest, Great Plains, Southwest, Northwest as in the National Climate Assessment (2014)) across the US. These experiments allow us to assess tradeoffs among electricity-water-climate to provide useful insight for decision-makers managing regional power production and aquatic environments.

  16. Design and Testing of a Breadboard Electrical Power Control Unit for the Fluid Combustion Facility Experiment

    Science.gov (United States)

    Kimnach, Greg L.; Lebron, Ramon C.

    1999-01-01

    The Fluid Combustion Facility (FCF) Project and the Power Technology Division at the NASA Glenn Research Center (GRC) at Lewis Field in Cleveland, OH along with the Sundstrand Corporation in Rockford, IL are jointly developing an Electrical Power Converter Unit (EPCU) for the Fluid Combustion Facility to be flown on the International Space Station (ISS). The FCF facility experiment contains three racks: A core rack, a combustion rack, and a fluids rack. The EPCU will be used as the power interface to the ISS 120V(sub dc) power distribution system by each FCF experiment rack which requires 28V(sub dc). The EPCU is a modular design which contains three 120V(sub dc)-to-28V(sub dc) full-bridge, power converters rated at 1 kW(sub e) each bus transferring input relays and solid-state, current-limiting input switches, 48 current-limiting, solid-state, output switches; and control and telemetry hardware. The EPCU has all controls required to autonomously share load demand between the power feeds and--if absolutely necessary--shed loads. The EPCU, which maximizes the usage of allocated ISS power and minimizes loss of power to loads, can be paralleled with other EPCUs. This paper overviews the electrical design and operating characteristics of the EPCU and presents test data from the breadboard design.

  17. Electric dipole moments of charged leptons and lepton flavor violating interactions in the general two Higgs doublet model

    International Nuclear Information System (INIS)

    Iltan, E. O.

    2001-01-01

    We calculate the electric dipole moment of the electron using the experimental result of the muon electric dipole moment and upper limit of the BR(μ->eγ) in the framework of the general two Higgs doublet model. Our prediction is 10 -32 ecm, which lies in the experimental current limits. Further, we obtain constraints for the Yukawa couplings {bar ξ} N,τe D and {bar ξ} N,τμ D . Finally, we present an expression which connects the BR(τ->μγ) and the electric dipole moment of the τ lepton and study the relation between these physical quantities

  18. 76 FR 11437 - Application To Export Electric Energy; Societe Generale Energy Corp.

    Science.gov (United States)

    2011-03-02

    ... reliability of the U.S. electric power supply system. Copies of this application will be made available, upon... surplus energy purchased from electric utilities, Federal power marketing agencies and other entities... DEPARTMENT OF ENERGY [OE Docket No. EA-376] Application To Export Electric Energy; Societe...

  19. Electricity

    CERN Document Server

    Basford, Leslie

    2013-01-01

    Electricity Made Simple covers the fundamental principles underlying every aspect of electricity. The book discusses current; resistance including its measurement, Kirchhoff's laws, and resistors; electroheat, electromagnetics and electrochemistry; and the motor and generator effects of electromagnetic forces. The text also describes alternating current, circuits and inductors, alternating current circuits, and a.c. generators and motors. Other methods of generating electromagnetic forces are also considered. The book is useful for electrical engineering students.

  20. Analysis of electrical systems from Cernavoda NPP - Unit 1 based on commissioning activity

    International Nuclear Information System (INIS)

    Goia, M.L.; Manolescu, I.

    1996-01-01

    Several design solutions regarding the electrical part of Cernavoda NPP Unit 1 station auxiliaries are discussed in this paper. The solutions mentioned may have different variants which should be taken into consideration in the design of Units U2 - U5. This work offers an ample debate on such matters as the supply source connection of the station auxiliaries, the use of two different voltages for the mean voltage (MV) supply, the consequence of the lack of breakers on the 24 kV part of station auxiliary transformers T03 - T04, the protection devices non correlated with the breakers to which they react, as well as the consequences of low subtransient reactance of the new stand-by Diesel generators. Besides these design solutions that can influence the station auxiliaries reliability, matters as malfunctioning of the dry type MV/LV transformers and unreliable behaviour of some MV composite insulators are also discussed. For some of the above mentioned problems the authors proposed several solutions. (authors). 1 fig., 1 tab

  1. Chaotic artificial immune approach applied to economic dispatch of electric energy using thermal units

    International Nuclear Information System (INIS)

    Santos Coelho, Leandro dos; Mariani, Viviana Cocco

    2009-01-01

    The economic dispatch problem (EDP) is an optimization problem useful in power systems operation. The objective of the EDP of electric power generation, whose characteristics are complex and highly non-linear, is to schedule the committed generating unit outputs so as to meet the required load demand at minimum operating cost while satisfying system constraints. Recently, as an alternative to the conventional mathematical approaches, modern heuristic optimization techniques have been given much attention by many researchers due to their ability to find an almost global optimal solution in EDPs. As special mechanism to avoid being trapped in local minimum, the ergodicity property of chaotic sequences has been used as optimization technique in EDPs. Based on the chaos theory, this paper discusses the design and validation of an optimization procedure based on a chaotic artificial immune network approach based on Zaslavsky's map. The optimization approach based on chaotic artificial immune network is validated for a test system consisting of 13 thermal units whose incremental fuel cost function takes into account the valve-point loading effects. Simulation results and comparisons show that the chaotic artificial immune network approach is competitive in performance with other optimization approaches presented in literature and is also an attractive tool to be used on applications in the power systems field.

  2. Size matters: Installed maximal unit size predicts market life cycles of electricity generation technologies and systems

    International Nuclear Information System (INIS)

    Li, N.

    2008-01-01

    The electricity generation technologies and systems are complex and change in very dynamic fashions, with a multitude of energy sources and prime movers. Since an important concept in generator design is the 'economies of scale', we discover that the installed maximal unit size (capacity) of the generators is a key 'envelope-pushing' characteristic with logistical behaviors. The logistical wavelet analysis of the max unit sizes for different fuels and prime movers, and the cumulative capacities, reveals universal quantitative features in the aggregate evolution of the power industry. We extract the transition times of the max sizes (spanning 10-90% of the saturation limits) for different technologies and systems, and discover that the max size saturation in the 90-99% range precedes the saturation of cumulative capacities of the corresponding systems in the US. While these universal laws are still empirical, they give us a simple yet elegant framework to examine the evolution of the power industry and markets in predictive, not just descriptive, terms. Such laws give us a quantitative tool to spot trends and predict future development, invaluable in planning and resource allocation based on intrinsic technology and system market life cycles

  3. Technical evaluation report on the monitoring of electric power to the reactor-protection system for the Brunswick Steam Electric Plant, Units 1 and 2

    International Nuclear Information System (INIS)

    Selan, J.C.

    1982-01-01

    This report documents the technical evaluation of the monitoring of electric power to the reactor protection system (RPS) at the Brunswick Steam Electric Plant, Units 1 and 2. The evaluation is to determine if the proposed design modification will protect the RPS from abnormal voltage and frequency conditions which could be supplied from the power supplies and will meet certain requirements set forth by the Nuclear Regulatory Commission. The proposed design modifications with time delays verified by GE, will protect the RPS from sustained abnormal voltage and frequency conditions from the supplying sources

  4. Potential air quality benefits from increased solar photovoltaic electricity generation in the Eastern United States

    Energy Technology Data Exchange (ETDEWEB)

    Abel, David; Holloway, Tracey; Harkey, Monica; Rrushaj, Arber; Brinkman, Greg; Duran, Phillip; Janssen, Mark; Denholm, Paul

    2018-02-01

    We evaluate how fine particulate matter (PM2.5) and precursor emissions could be reduced if 17% of electricity generation was replaced with solar photovoltaics (PV) in the Eastern United States. Electricity generation is simulated using GridView, then used to scale electricity-sector emissions of sulfur dioxide (SO2) and nitrogen oxides (NOX) from an existing gridded inventory of air emissions. This approach offers a novel method to leverage advanced electricity simulations with state-of-the-art emissions inventories, without necessitating recalculation of emissions for each facility. The baseline and perturbed emissions are input to the Community Multiscale Air Quality Model (CMAQ version 4.7.1) for a full accounting of time- and space-varying air quality changes associated with the 17% PV scenario. These results offer a high-value opportunity to evaluate the reduced-form AVoided Emissions and geneRation Tool (AVERT), while using AVERT to test the sensitivity of results to changing base-years and levels of solar integration. We find that average NOX and SO2 emissions across the region decrease 20% and 15%, respectively. PM2.5 concentrations decreased on average 4.7% across the Eastern U.S., with nitrate (NO3-) PM2.5 decreasing 3.7% and sulfate (SO42-) PM2.5 decreasing 9.1%. In the five largest cities in the region, we find that the most polluted days show the most significant PM2.5 decrease under the 17% PV generation scenario, and that the greatest benefits are accrued to cities in or near the Ohio River Valley. We find summer health benefits from reduced PM2.5 exposure estimated as 1424 avoided premature deaths (95% Confidence Interval (CI): 284 deaths, 2 732 deaths) or a health savings of $13.1 billion (95% CI: $0.6 billion, $43.9 billion) These results highlight the potential for renewable energy as a tool for air quality managers to support current and future health-based air quality regulations.

  5. Potential air quality benefits from increased solar photovoltaic electricity generation in the Eastern United States

    Science.gov (United States)

    Abel, David; Holloway, Tracey; Harkey, Monica; Rrushaj, Arber; Brinkman, Greg; Duran, Phillip; Janssen, Mark; Denholm, Paul

    2018-02-01

    We evaluate how fine particulate matter (PM2.5) and precursor emissions could be reduced if 17% of electricity generation was replaced with solar photovoltaics (PV) in the Eastern United States. Electricity generation is simulated using GridView, then used to scale electricity-sector emissions of sulfur dioxide (SO2) and nitrogen oxides (NOX) from an existing gridded inventory of air emissions. This approach offers a novel method to leverage advanced electricity simulations with state-of-the-art emissions inventories, without necessitating recalculation of emissions for each facility. The baseline and perturbed emissions are input to the Community Multiscale Air Quality Model (CMAQ version 4.7.1) for a full accounting of time- and space-varying air quality changes associated with the 17% PV scenario. These results offer a high-value opportunity to evaluate the reduced-form AVoided Emissions and geneRation Tool (AVERT), while using AVERT to test the sensitivity of results to changing base-years and levels of solar integration. We find that average NOX and SO2 emissions across the region decrease 20% and 15%, respectively. PM2.5 concentrations decreased on average 4.7% across the Eastern U.S., with nitrate (NO3-) PM2.5 decreasing 3.7% and sulfate (SO42-) PM2.5 decreasing 9.1%. In the five largest cities in the region, we find that the most polluted days show the most significant PM2.5 decrease under the 17% PV generation scenario, and that the greatest benefits are accrued to cities in or near the Ohio River Valley. We find summer health benefits from reduced PM2.5 exposure estimated as 1424 avoided premature deaths (95% Confidence Interval (CI): 284 deaths, 2 732 deaths) or a health savings of 13.1 billion (95% CI: 0.6 billion, 43.9 billion) These results highlight the potential for renewable energy as a tool for air quality managers to support current and future health-based air quality regulations.

  6. Comprehensive Technical Report, General Electric Direct-Air-Cycle Aircraft Nuclear Propulsion Program, Program Summary and References

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, G.; Rothstein, A.J.

    1962-06-28

    This is one of twenty-one volumes sumarizing the Aircraft Nuclear Propulsion Program of the General Electric Company. This volume discusses the background to the General Electric program, and summarizes the various direct-air-cycle nuclear test assemblies and power plants that were developed. Because of the requirements of high performance, low weight, and small size, vast improvements in existing technology were required to meet the flight objectives. The technological progress achieved during the program is also summarized. The last appendix contains a compilation of the abstracts, tables of contents, and reference lists of the other twenty volumes.

  7. Testing of the Engineering Model Electrical Power Control Unit for the Fluids and Combustion Facility

    Science.gov (United States)

    Kimnach, Greg L.; Lebron, Ramon C.; Fox, David A.

    1999-01-01

    The John H. Glenn Research Center at Lewis Field (GRC) in Cleveland, OH and the Sundstrand Corporation in Rockford, IL have designed and developed an Engineering Model (EM) Electrical Power Control Unit (EPCU) for the Fluids Combustion Facility, (FCF) experiments to be flown on the International Space Station (ISS). The EPCU will be used as the power interface to the ISS power distribution system for the FCF's space experiments'test and telemetry hardware. Furthermore. it is proposed to be the common power interface for all experiments. The EPCU is a three kilowatt 12OVdc-to-28Vdc converter utilizing three independent Power Converter Units (PCUs), each rated at 1kWe (36Adc @ 28Vdc) which are paralleled and synchronized. Each converter may be fed from one of two ISS power channels. The 28Vdc loads are connected to the EPCU output via 48 solid-state and current-limiting switches, rated at 4Adc each. These switches may be paralleled to supply any given load up to the 108Adc normal operational limit of the paralleled converters. The EPCU was designed in this manner to maximize allocated-power utilization. to shed loads autonomously, to provide fault tolerance. and to provide a flexible power converter and control module to meet various ISS load demands. Tests of the EPCU in the Power Systems Facility testbed at GRC reveal that the overall converted-power efficiency, is approximately 89% with a nominal-input voltage of 12OVdc and a total load in the range of 4O% to 110% rated 28Vdc load. (The PCUs alone have an efficiency of approximately 94.5%). Furthermore, the EM unit passed all flight-qualification level (and beyond) vibration tests, passed ISS EMI (conducted, radiated. and susceptibility) requirements. successfully operated for extended periods in a thermal/vacuum chamber, was integrated with a proto-flight experiment and passed all stability and functional requirements.

  8. Seismic risk analysis for General Electric Plutonium Facility, Pleasanton, California. Final report, part II

    International Nuclear Information System (INIS)

    1980-01-01

    This report is the second of a two part study addressing the seismic risk or hazard of the special nuclear materials (SNM) facility of the General Electric Vallecitos Nuclear Center at Pleasanton, California. The Part I companion to this report, dated July 31, 1978, presented the seismic hazard at the site that resulted from exposure to earthquakes on the Calaveras, Hayward, San Andreas and, additionally, from smaller unassociated earthquakes that could not be attributed to these specific faults. However, while this study was in progress, certain additional geologic information became available that could be interpreted in terms of the existance of a nearby fault. Although substantial geologic investigations were subsequently deployed, the existance of this postulated fault, called the Verona Fault, remained very controversial. The purpose of the Part II study was to assume the existance of such a capable fault and, under this assumption, to examine the loads that the fault could impose on the SNM facility. This report first reviews the geologic setting with a focus on specifying sufficient geologic parameters to characterize the postulated fault. The report next presents the methodology used to calculate the vibratory ground motion hazard. Because of the complexity of the fault geometry, a slightly different methodology is used here compared to the Part I report. This section ends with the results of the calculation applied to the SNM facility. Finally, the report presents the methodology and results of the rupture hazard calculation

  9. Standard technical specifications General Electric plants, BWR/6. Volume 1, Revision 1

    International Nuclear Information System (INIS)

    1995-04-01

    This report documents the results of the combined effort of the NRC and the industry to produce improved Standard Technical Specifications (STS), Revision 1 for General Electric BWR/6 Plants. The changes reflected in Revision 1 resulted from the experience gained from license amendment applications to convert to these improved STS or to adopt partial improvements to existing technical specifications. This NUREG is the result of extensive public technical meetings and discussions between the Nuclear Regulatory Commission (NRC) staff and various nuclear power plant licensees, Nuclear Steam Supply System (NSSS) Owners Groups, NSSS vendors, and the Nuclear Energy Institute (NEI). The improved STS were developed based on the criteria in the Final Commission Policy Statement on Technical Specifications Improvements for Nuclear Power Reactors, dated July 22, 1993. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4--3.10 of the improved STS

  10. Standard technical specifications: General Electric plants, BWR/4. Volume 1, Revision 1: Specifications

    International Nuclear Information System (INIS)

    1995-04-01

    This report documents the results of the combined effort of the NRC and the industry to produce improved Standard Technical Specifications (STS), Revision 1 for General Electric BWR/4 Plants. The changes reflected in Revision 1 resulted from the experience gained from license amendment applications to convert to these improved STS or to adopt partial improvements to existing technical specifications. This NUREG is the result of extensive public technical meetings and discussions between the Nuclear Regulatory Commission (NRC) staff and various nuclear power plant licensees, Nuclear Steam Supply System (NSSS) Owners Groups, NSSS vendors, and the Nuclear Energy Institute (NEI). The improved STS were developed based on the criteria in the Final Commission Policy Statement on Technical Specifications Improvements for Nuclear Power Reactors, dated July 22, 1993. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4--3.10 of the improved STS

  11. Analysis of the General Electric Company swell tests with RELAP4/MOD7

    International Nuclear Information System (INIS)

    Fischer, S.R.; Hendrix, C.E.

    1979-01-01

    The RELAP4/MOD7 nuclear reactor transient analysis code, presently being developed by EG and G Idaho, Inc., will incorporate several significant improvements over earlier versions of RELAP4. As part of the development of RELAP4/MOD7, a thorough assessment of the capability of the code to simulate water reactor LOCA phenomena is being made. This assessment is accomplished in part by comparing results from code calculations with test data from experimental facilities. Simulations of the General Electric Company (GE) level swell tests were performed as part of the code checkout. In these tests, a pressurized vessel partially filled with nearly saturated water was blown down through a simulated break located near the top of the vessel. Comparison of RELAP4 calculations with data from these experiments indicates that the code has the capability to model the unequal phase velocity flow and resulting density gradients that might occur in a BWR steam line break transient. Comparisons of RELAP4 calculations with data from two level swell experiments are presented

  12. NRC [Nuclear Regulatory Commission] staff evaluation of the General Electric Company Nuclear Reactor Study (''Reed Report'')

    International Nuclear Information System (INIS)

    1987-07-01

    In 1975, the General Electric Company (GE) published a Nuclear Reactor Study, also referred to as ''the Reed Report,'' an internal product-improvement study. GE considered the document ''proprietary'' and thus, under the regulations of the Nuclear Regulatory Commission (NRC), exempt from mandatory public disclosure. Nonetheless, members of the NRC staff reviewed the document in 1976 and determined that it did not raise any significant new safety issues. The staff also reached the same conclusion in subsequent reviews. However, in response to recent inquiries about the report, the staff reevaluated the Reed Report from a 1987 perspective. This re-evaluation, documented in this staff report, concluded that: (1) there are no issues raised in the Reed Report that support a need to curtail the operation of any GE boiling water reactor (BWR); (2) there are no new safety issues raised in the Reed Report of which the staff was unaware; and (3) although certain issues addressed by the Reed Report are still being studied by the NRC and the industry, there is no basis for suspending licensing and operation of GE BWR plants while these issues are being resolved

  13. A generalized model for transport of contaminants in soil by electric fields.

    Science.gov (United States)

    Paz-Garcia, Juan Manuel; Baek, Kitae; Alshawabkeh, Iyad D; Alshawabkeh, Akram N

    2012-01-01

    A generalized model applicable to soils contaminated with multiple species under enhanced boundary conditions during treatment by electric fields is presented. The partial differential equations describing species transport are developed by applying the law of mass conservation to their fluxes. Transport, due to migration, advection and diffusion, of each aqueous component and complex species are combined to produce one partial differential equation that describes transport of the total analytical concentrations of component species which are the primary dependent variables. This transport couples with geochemical reactions such as aqueous equilibrium, sorption, precipitation and dissolution. The enhanced model is used to simulate electrokinetic cleanup of lead and copper contaminants at an Army Firing Range. Acid enhancement is achieved by the use of adipic acid to neutralize the basic front produced for the cathode electrochemical reaction. The model is able to simulate enhanced application of the process by modifying the boundary conditions. The model showed that kinetics of geochemical reactions, such as metals dissolution/leaching and redox reactions, may be significant for realistic prediction of enhanced electrokinetic extraction of metals in real-world applications.

  14. Aging assessment of Westinghouse PWR and General Electric BWR containment isolation functions

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B.S.; Travis, R.; Grove, E.; DiBiasio, A.

    1996-03-01

    A study was performed to assess the effects of aging on the Containment Isolation (CI) functions of Westinghouse Pressurized Water Reactors and General Electric Boiling Water Reactors. This study is part of the Nuclear Plant Aging Research (NPAR) program, sponsored by the U.S. Nuclear Regulatory Commission. The objectives of this program are to provide an understanding of the aging process and how it affects plant safety so that it can be properly managed. This is one of a number of studies performed under the NPAR program which provide a technical basis for the identification and evaluation of degradation caused by age. Failure data from two national databases, Nuclear Plant Reliability Data System (NPRDS) and Licensee Event Reports (LERs), as well as plant specific data were reviewed and analyzed to understand the effects of aging on the CI functions. This study provided information on the effects of aging on component failure frequency, failure modes, and failure causes. Current inspection, surveillance, and monitoring practices were also reviewed.

  15. Aging assessment of Westinghouse PWR and General Electric BWR containment isolation functions

    International Nuclear Information System (INIS)

    Lee, B.S.; Travis, R.; Grove, E.; DiBiasio, A.

    1996-03-01

    A study was performed to assess the effects of aging on the Containment Isolation (CI) functions of Westinghouse Pressurized Water Reactors and General Electric Boiling Water Reactors. This study is part of the Nuclear Plant Aging Research (NPAR) program, sponsored by the U.S. Nuclear Regulatory Commission. The objectives of this program are to provide an understanding of the aging process and how it affects plant safety so that it can be properly managed. This is one of a number of studies performed under the NPAR program which provide a technical basis for the identification and evaluation of degradation caused by age. Failure data from two national databases, Nuclear Plant Reliability Data System (NPRDS) and Licensee Event Reports (LERs), as well as plant specific data were reviewed and analyzed to understand the effects of aging on the CI functions. This study provided information on the effects of aging on component failure frequency, failure modes, and failure causes. Current inspection, surveillance, and monitoring practices were also reviewed

  16. Smart electric grids. Economic and environmental value, general implementation. September 2017. Contribution by RTE - Full report

    International Nuclear Information System (INIS)

    2017-09-01

    This report is the RTE's contribution to studies commissions by public authorities on the social and economic valorisation of smart grids for the different actors. It first proposes an overview of the various considered technical and technological solutions: storage, active management of residential, tertiary and industrial demand, and steerability of renewable energies. After a recall of objectives related to the development of smart grids, the report reviews the methodological framework adopted for a previous study (general principles, modelling principles for the electricity system operation, use of the Flexis model, economic and environmental assessment), and proposes an overview of methodological developments achieved since 2015. It discusses how this study compares with others related to smart grid flexibility published in France and in Europe. Then, after having stated some hypotheses, the report presents the analytical framework for quantitative results, discusses economic and environmental assessments performed for each solution (storage, active management for different sectors, and steerability of wind energy production). The next part presents different global economically relevant scenarios of smart grid deployment, with assessments by 2030

  17. The water implications of generating electricity: water use across the United States based on different electricity pathways through 2050

    International Nuclear Information System (INIS)

    Macknick, J; Sattler, S; Clemmer, S; Rogers, J; Averyt, K

    2012-01-01

    The power sector withdraws more freshwater annually than any other sector in the US. The current portfolio of electricity generating technologies in the US has highly regionalized and technology-specific requirements for water. Water availability differs widely throughout the nation. As a result, assessments of water impacts from the power sector must have a high geographic resolution and consider regional, basin-level differences. The US electricity portfolio is expected to evolve in coming years, shaped by various policy and economic drivers on the international, national and regional level; that evolution will impact power sector water demands. Analysis of future electricity scenarios that incorporate technology options and constraints can provide useful insights about water impacts related to changes to the technology mix. Utilizing outputs from the regional energy deployment system (ReEDS) model, a national electricity sector capacity expansion model with high geographical resolution, we explore potential changes in water use by the US electric sector over the next four decades under various low carbon energy scenarios, nationally and regionally. (letter)

  18. Non-electrical Application of Nuclear Energy: Some General Issues and Prospects

    International Nuclear Information System (INIS)

    Kuznetsov, Yu. N.

    2008-01-01

    Co-generation power plants (CPP) are widely used in Russia with its harsh climate and low temperatures. The EU directive encourages further development of co-generation plants as the most efficient and rapid way of energy saving and reduction of CO 2 emissions. Nuclear power facilities can be used efficiently at co-generation power plants. The author discuss requirements for nuclear co-generation power plants (NCPP) from the viewpoint of power level, safety and economics, and look into various approaches towards development of dedicated reactor systems and nuclear units for NCPP so as to meet these requirements. It is shown that the most effective approach is consistent implementation of the principles of design simplicity and passive operation of the main reactors systems and components. The implementation of this approach is illustrated on the example of two Russian developments - VK-300 (Russian SBWR) and RUTA (a pool-type facility). The paper describes in detail the findings of a feasibility study on a project of a co-generation nuclear plant in the Arkhangelsk region of Russia. The CNPP's total power is planned to be 1000 MW(e) and district-heating heat production capacity 1600 Gcal /h. The study has proved the feasibility of NCPP construction in the Arkhangelsk region in terms of engineering solutions, economics and, importantly, from the viewpoint of social benefits. The prospects for NCPP development in Russia are analyzed. Considering the increasing global trend towards the use of desalination and the stable growth of demand for such techniques, Russia has been paying great attention to this technology.The authors look into the prospects of NCPP application for sea water desalination. A Nuclear Desalination Complex (NDC) with VK-300 reactor facility is described as an illustration. The most attractive option is coupling of a VK-300 energy source with distillation desalination units operating based on a multi-stage evaporation principle (MED). This is an

  19. Relationship between the merit factor of thermoelectric materials and the air conditioning unit of urban electric cars

    International Nuclear Information System (INIS)

    Buffet, J.

    1994-01-01

    The main benefit of electric cars is to reduce air pollution in cities that is thus desirable to equip them with non polluting air conditioning units and this rules out frigorific compressors operating with CFC. The planned replacement of CFC by HFC is at best an interim solution. The best solution is certainly to use thermoelectric air conditioning units, which are inherently pollution-free. However, these have a fairly low COPF when compared to traditional compressor units. We study the relationship between the cooling of the interior of urban electric cars and the merit factor of the thermoelectric material in their Peltier unit. This should help provide concrete target properties of future T E materials. copyright 1995 American Institute of Physics

  20. Method for heating of the primary circuit of WWER electric power units at cold start-up

    International Nuclear Information System (INIS)

    Ivanov, I.N.; Dimitrov, B.D.; Korkinova, M.I.

    1982-01-01

    The method increases the heating rate and shorten the start-up time of the electric power units. It comprises a primary stopping of the reactor core heating and provides a forced circulation of the heat-carrier through the circulation cycles of the primary circuit. The thermal energy is supplied in one or several steam generators in the secondary circuit of an NPP operating unit. 1 cl., 3 figs

  1. Quality of stroke care at an Irish Regional General Hospital and Stroke Rehabilitation Unit.

    LENUS (Irish Health Repository)

    Walsh, T

    2012-01-31

    BACKGROUND: Robust international data support the effectiveness of stroke unit (SU) care. Despite this, most stroke care in Ireland are provided outside of this setting. Limited data currently exist on the quality of care provided. AIM: The aim of this study is to examine the quality of care for patients with stroke in two care settings-Regional General Hospital (RGH) and Stroke Rehabilitation Unit (SRU). METHODS: A retrospective analysis of the stroke records of consecutive patients admitted to the SRU between May-November 2002 and April-November 2004 was performed applying the UK National Sentinel Audit of Stroke (NSAS) tool. RESULTS: The results of the study reveal that while SRU processes of care was 74% compliant with standards; compliance with stroke service organisational standards was only 15 and 43% in the RGH and SRU, respectively. CONCLUSION: The quality of stroke care in our area is deficient. Comprehensive reorganisation of stroke services is imperative.

  2. Statement to Sixty-Seventh Regular Session of United Nations General Assembly, 5 Nov 2012, New York, United States

    International Nuclear Information System (INIS)

    Amano, Y.

    2012-01-01

    When I addressed the General Assembly a year ago, I spoke at some length about the accident at the Fukushima Daiichi nuclear power plant in Japan in March 2011. The aftermath of the devastating earthquake and tsunami dominated the work of the IAEA for much of that year. We are now well into the post-accident phase. The focus is on implementing the IAEA Action Plan on Nuclear Safety which was adopted by our Member States last year. Progress has been made in many areas. Measures have been taken to improve protection against extreme hazards such as earthquakes and tsunamis. Countries are upgrading their emergency preparedness and response capabilities. IAEA safety standards are being reviewed. Our programme of expert peer review services is being expanded. A key priority for all nuclear power plant operators has been establishing reliable back-up electricity supply in the event of a prolonged blackout. Already, it is fair to say that nuclear power is safer than it was before the Fukushima Daiichi accident. But the process of ensuring that the right lessons are learned will continue for many years. It is essential that the Action Plan is implemented in full. Next month, the IAEA and the Government of Japan will hold a Ministerial Conference on Nuclear Safety in Fukushima Prefecture. At this Conference, we will present the conclusions of international expert meetings on issues such as reactor and spent fuel safety, responding to tsunamis and earthquakes, and transparency and communication. We will also prepare a comprehensive report on the Fukushima Daiichi accident, to be finalized in 2014. The lasting legacy of the accident will be a much more intense focus on safety. Nuclear safety remains the responsibility of individual countries. However, governments have recognized that effective international cooperation is vitally important and that the IAEA has a unique role to play. (IAEA)

  3. Citar documentos electrónicos. Revisión de propuestas y planteamiento de pautas generales

    Directory of Open Access Journals (Sweden)

    Mari Carmen Marcos Mora

    2002-01-01

    Full Text Available Se recogen las propuestas de normalización de citas de documentos electrónicos de varios autores que a su vez se basan para desarrollarlas en los estilos publicados por la ISO, la APA y la MLA. Se ofrecen unas pautas generales de aplicación que suponen una unificación de las presentadas

  4. 75 FR 11920 - General Electric Lighting-Ravenna Lamp Plant, Lighting Division, Including On-Site Leased Workers...

    Science.gov (United States)

    2010-03-12

    ... to the production of high intensity discharge lamps. The review shows that on August 24, 2007, a...-Ravenna Lamp Plant, Lighting Division, Including On-Site Leased Workers from Devore Technologies, Ravenna..., 2009, applicable to workers of General Electric Lighting-Ravenna Lamp Plant, Lighting Division...

  5. 77 FR 14838 - General Electric-Hitachi Global Laser Enrichment LLC, Commercial Laser-Based Uranium Enrichment...

    Science.gov (United States)

    2012-03-13

    ... Laser Enrichment LLC, Commercial Laser-Based Uranium Enrichment Facility, Wilmington, North Carolina... a license to General Electric-Hitachi Global Laser Enrichment LLC (GLE or the applicant) to authorize construction of a laser-based uranium enrichment facility and possession and use of byproduct...

  6. Differential Treatment of Pregnancy in Employment: The Impact of "General Electric Co. v. Gilbert" and "Nashville Gas Co. v. Satty."

    Science.gov (United States)

    Taylor, Ellen T.

    1978-01-01

    After discussing the facts and reasoning of the two cases (General Electric Co. vs Gilbert and Nashville Gas Co. vs Satty), the author argues that the decisions are largely the product of pregnancy stereotypes and that the Court's reasoning is flawed and should not be applied outside the context of pregnancy. Journal availability: see EA 511 481.…

  7. 75 FR 11918 - General Electric Kentucky Glass Plant, Lighting, LLC, Including On-Site Leased Workers From the...

    Science.gov (United States)

    2010-03-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-72,011] General Electric Kentucky Glass Plant, Lighting, LLC, Including On-Site Leased Workers From the Patty Tipton Company, Aetna Building Maintenance, and Concentra, Lexington, KY; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordanc...

  8. How did the General Purpose Technology Electricity contribute to the Second Industrial Revolution (II): The Communication Engines

    NARCIS (Netherlands)

    van der Kooij, B.J.G.

    2017-01-01

    The concept of the General Purpose Technology (GPT) of the late 1990s is a culmination of many evolutionairy views in innovation-thinking. By definition the GPT considers the technical, social, and economic effects of meta-technologies like steam-technology and electric technology. This paper uses

  9. Change in consumer sensitivity to electricity prices in response to retail deregulation: A panel empirical analysis of the residential demand for electricity in the United States

    International Nuclear Information System (INIS)

    Nakajima, Tadahiro; Hamori, Shigeyuki

    2010-01-01

    About ten years have passed since the deregulation of the U.S. retail electricity market, and it is now generally accepted that the available data is adequate to quantitatively assess and compare conditions before and after deregulation. This study, therefore, estimates the changes in price elasticity in the residential electricity market to examine the changes, if any, in household sensitivity (as a result of retail electricity market deregulation policies) to residential electricity rates. Specifically, six types of panel data are prepared, based on three cross-sections-all states (except for Alaska and Hawaii) and the District of Columbia, deregulated states, and non-deregulated states-and two time series-the period before deregulation and the period after deregulation. The panel empirical analysis techniques are used to determine whether or not the variables are stationary, and to estimate price elasticity. We find that there is no substantial difference in the price elasticity between deregulated and non-deregulated states for both periods-before deregulation and after deregulation. Thus, it can be said that the deregulation of the retail electricity market has not made consumers more sensitive to electricity rates and that retail deregulation policies are not the cause of price elasticity differences between deregulated and non-deregulated states.

  10. Change in consumer sensitivity to electricity prices in response to retail deregulation. A panel empirical analysis of the residential demand for electricity in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Tadahiro [The Kansai Electric Power Company, Incorporated, 6-16, Nakanoshima 3-chome, Kita-Ku, Osaka 530-8270 (Japan); Hamori, Shigeyuki [Faculty of Economics, Kobe University 2-1, Rokkodai, Nada-Ku, Kobe 657-8501 (Japan)

    2010-05-15

    About ten years have passed since the deregulation of the U.S. retail electricity market, and it is now generally accepted that the available data is adequate to quantitatively assess and compare conditions before and after deregulation. This study, therefore, estimates the changes in price elasticity in the residential electricity market to examine the changes, if any, in household sensitivity (as a result of retail electricity market deregulation policies) to residential electricity rates. Specifically, six types of panel data are prepared, based on three cross-sections - all states (except for Alaska and Hawaii) and the District of Columbia, deregulated states, and non-deregulated states - and two time series - the period before deregulation and the period after deregulation. The panel empirical analysis techniques are used to determine whether or not the variables are stationary, and to estimate price elasticity. We find that there is no substantial difference in the price elasticity between deregulated and non-deregulated states for both periods - before deregulation and after deregulation. Thus, it can be said that the deregulation of the retail electricity market has not made consumers more sensitive to electricity rates and that retail deregulation policies are not the cause of price elasticity differences between deregulated and non-deregulated states. (author)

  11. Comparative clinical evaluation of a prototype non-electric transport incubator and an electrical infant incubator in a neonatal unit.

    Science.gov (United States)

    Khodadadeh, Y; Nili, F; Nayeri, F; Wickramasinghe, Y

    2001-09-01

    A new non-electric transport incubator has been developed for transferring babies between health facilities in developing countries. The temperature performance of this prototype was compared with a commercial electric incubator. The warm-up time for the prototype was 51.8 min, compared with 48.1 min for the electric incubator. Forty-five non-distressed premature babies, aged 24-72 h, with a gestational age of less than 37 weeks, were continuously evaluated for a 2 h period. Twenty-five babies, with a mean weight of 2073 g (range 1500-2500 g), were studied in the prototype, and 20 babies, with a mean weight of 2076g (range 1550-2500 g), were studied in the electrical incubator. The rectal and abdominal skin temperature, heart rate, oxygen saturation and respiratory rate of the babies were recorded. The temperature, oxygen and humidity level of the canopy and the room temperature were also measured. The SaO2, heart rate and respiratory rate were within the normal range (in the prototype: 96.5%, 130.5 beats min(-1) and 43 breaths min(-1), respectively; and, in the electric incubator: 96.5%, 128.5 beats min(-1) and 40 breaths min(-1), respectively). No evidence of carbon dioxide narcosis, hypoxia, acidosis or adverse thermoregulatory behaviour were observed in the two groups. The mean rectal temperature for both groups was within the range 36.5 degrees C-37.5 degrees C. There was no significant difference between the measurements of the two groups. The level of oxygen inside the canopy was 21%, and no decrease was observed. The new nonelectric transport incubator confirmed its safety and efficiency in providing a warm environment for non-distressed premature babies over a 2 h period.

  12. Assessment of inappropriate antibiotic prescribing among a large cohort of general dentists in the United States.

    Science.gov (United States)

    Durkin, Michael J; Feng, Qianxi; Warren, Kyle; Lockhart, Peter B; Thornhill, Martin H; Munshi, Kiraat D; Henderson, Rochelle R; Hsueh, Kevin; Fraser, Victoria J

    2018-05-01

    The purpose of this study was to assess dental antibiotic prescribing trends over time, to quantify the number and types of antibiotics dentists prescribe inappropriately, and to estimate the excess health care costs of inappropriate antibiotic prescribing with the use of a large cohort of general dentists in the United States. We used a quasi-Poisson regression model to analyze antibiotic prescriptions trends by general dentists between January 1, 2013, and December 31, 2015, with the use of data from Express Scripts Holding Company, a large pharmacy benefits manager. We evaluated antibiotic duration and appropriateness for general dentists. Appropriateness was evaluated by reviewing the antibiotic prescribed and the duration of the prescription. Overall, the number and rate of antibiotic prescriptions prescribed by general dentists remained stable in our cohort. During the 3-year study period, approximately 14% of antibiotic prescriptions were deemed inappropriate, based on the antibiotic prescribed, antibiotic treatment duration, or both indicators. The quasi-Poisson regression model, which adjusted for number of beneficiaries covered, revealed a small but statistically significant decrease in the monthly rate of inappropriate antibiotic prescriptions by 0.32% (95% confidence interval, 0.14% to 0.50%; P = .001). Overall antibiotic prescribing practices among general dentists in this cohort remained stable over time. The rate of inappropriate antibiotic prescriptions by general dentists decreased slightly over time. From these authors' definition of appropriate antibiotic prescription choice and duration, inappropriate antibiotic prescriptions are common (14% of all antibiotic prescriptions) among general dentists. Further analyses with the use of chart review, administrative data sets, or other approaches are needed to better evaluate antibiotic prescribing practices among dentists. Copyright © 2018 American Dental Association. Published by Elsevier Inc. All

  13. General purpose graphics-processing-unit implementation of cosmological domain wall network evolution.

    Science.gov (United States)

    Correia, J R C C C; Martins, C J A P

    2017-10-01

    Topological defects unavoidably form at symmetry breaking phase transitions in the early universe. To probe the parameter space of theoretical models and set tighter experimental constraints (exploiting the recent advances in astrophysical observations), one requires more and more demanding simulations, and therefore more hardware resources and computation time. Improving the speed and efficiency of existing codes is essential. Here we present a general purpose graphics-processing-unit implementation of the canonical Press-Ryden-Spergel algorithm for the evolution of cosmological domain wall networks. This is ported to the Open Computing Language standard, and as a consequence significant speedups are achieved both in two-dimensional (2D) and 3D simulations.

  14. Special Inspector General for Iraq Reconstruction Quarterly Report to the United States Congress

    Science.gov (United States)

    2012-04-30

    developed during the intervening period.430 Th e United States, which expects to ship about $120 million–$130 million worth of poultry to Iraq in 2012...special assessment Thomas A. Manok, former USACE employee Conspiracy 9/19/2011 20 months in prison; 3 years supervised release; forfeiture of $73,500...Joseph Sebastian 12/13/2010 N.K. Ismail 12/13/2010 Biju Thomas 12/13/2010 Combat General Trading Company 12/13/2010 Jank Singh 11/24/2010 Blue Marine

  15. General purpose graphics-processing-unit implementation of cosmological domain wall network evolution

    Science.gov (United States)

    Correia, J. R. C. C. C.; Martins, C. J. A. P.

    2017-10-01

    Topological defects unavoidably form at symmetry breaking phase transitions in the early universe. To probe the parameter space of theoretical models and set tighter experimental constraints (exploiting the recent advances in astrophysical observations), one requires more and more demanding simulations, and therefore more hardware resources and computation time. Improving the speed and efficiency of existing codes is essential. Here we present a general purpose graphics-processing-unit implementation of the canonical Press-Ryden-Spergel algorithm for the evolution of cosmological domain wall networks. This is ported to the Open Computing Language standard, and as a consequence significant speedups are achieved both in two-dimensional (2D) and 3D simulations.

  16. Levelised unit electricity cost comparison of alternate technologies for baseload generation in Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Ayres, M.; McRae, M.; Stogran, M.

    2004-08-15

    This report provides a comparison of the lifetime cost of constructing, operating and decommissioning new generation suitable for supplying baseload power by early in the next decade. New baseload generation options in Ontario are nuclear, coal-fired steam turbines or combined cycle gas turbines (CCGT). Nuclear and coal-fired units are characterised by high capital costs and low operating costs. As such, they are candidates for baseload operation only. Gas-fired generation is characterised by lower capital costs and higher operating costs and thus may meet the requirements for operation as peaking and/or baseload generation. The comparison of baseload generating technologies is made by reference to the estimated levelised unit electricity cost (LUEC). The LUEC can be thought of as a 'supply cost', where the unit cost is the price needed to recover all costs over the period. It is determined by finding the price that sets the sum of all future discounted cash flows (net present value, or NPV) to zero. It can also be thought of as representing the constant real wholesale price of electricity that meets the financing cost, debt repayment, income tax and cash flow constraints associated with the construction operation and decommissioning of a generating plant. Levelised unit cost comparisons are usually made with different sets of financing assumptions. This report considers two base cases, which we describe as 'merchant' and 'public' financing. The term 'merchant plant' is used to refer to ones that are built and operated by private investors. These investors pay for their capital through debt and by raising equity, and thus pay return on equity and interest on debt throughout their lifetime. These projects include income taxes, both provincial and federal. Publicly financed projects typically are not subject to income taxes or to the same constraints on raising finance through issuing debt and equity. However, they are

  17. Levelised unit electricity cost comparison of alternate technologies for baseload generation in Ontario

    International Nuclear Information System (INIS)

    Ayres, M.; McRae, M.; Stogran, M.

    2004-08-01

    This report provides a comparison of the lifetime cost of constructing, operating and decommissioning new generation suitable for supplying baseload power by early in the next decade. New baseload generation options in Ontario are nuclear, coal-fired steam turbines or combined cycle gas turbines (CCGT). Nuclear and coal-fired units are characterised by high capital costs and low operating costs. As such, they are candidates for baseload operation only. Gas-fired generation is characterised by lower capital costs and higher operating costs and thus may meet the requirements for operation as peaking and/or baseload generation. The comparison of baseload generating technologies is made by reference to the estimated levelised unit electricity cost (LUEC). The LUEC can be thought of as a 'supply cost', where the unit cost is the price needed to recover all costs over the period. It is determined by finding the price that sets the sum of all future discounted cash flows (net present value, or NPV) to zero. It can also be thought of as representing the constant real wholesale price of electricity that meets the financing cost, debt repayment, income tax and cash flow constraints associated with the construction operation and decommissioning of a generating plant. Levelised unit cost comparisons are usually made with different sets of financing assumptions. This report considers two base cases, which we describe as 'merchant' and 'public' financing. The term 'merchant plant' is used to refer to ones that are built and operated by private investors. These investors pay for their capital through debt and by raising equity, and thus pay return on equity and interest on debt throughout their lifetime. These projects include income taxes, both provincial and federal. Publicly financed projects typically are not subject to income taxes or to the same constraints on raising finance through issuing debt and equity. However, they are constrained to provide a rate of return. The

  18. 76 FR 388 - Southern Nuclear Operating Company; Vogtle Electric Generating Plant, Unit Nos. 1 and 2; Notice...

    Science.gov (United States)

    2011-01-04

    ... Operating Company; Vogtle Electric Generating Plant, Unit Nos. 1 and 2; Notice of Consideration of Issuance... Web site http://www.regulations.gov . Because your comments will not be edited to remove any... will not edit their comments to remove any identifying or contact information, and therefore, they...

  19. 76 FR 30206 - Southern Nuclear Operating Company, Inc., Vogtle Electric Generating Plant, Unit 1 and 2; Notice...

    Science.gov (United States)

    2011-05-24

    ... Operating Company, Inc., Vogtle Electric Generating Plant, Unit 1 and 2; Notice of Consideration of Issuance..., http://www.regulations.gov . Because your comments will not be edited to remove any identifying or... received from other persons for submission to the NRC inform those persons that the NRC will not edit their...

  20. 75 FR 75704 - Pacific Gas and Electric Company (Diablo Canyon Nuclear Power Plant, Units 1 And 2); Notice of...

    Science.gov (United States)

    2010-12-06

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-275-LR; 50-323-LR] Pacific Gas and Electric Company (Diablo Canyon Nuclear Power Plant, Units 1 And 2); Notice of Appointment of Adjudicatory Employee... Seismologist, Office of Nuclear Material Safety and Safeguards, has been appointed as a Commission adjudicatory...

  1. EQUATIONS OF ELECTRIC MOTOR POWER SUPPLY UNIT DISSYMMETRY UNDER PHASE-TO-PHASE SHORT-CIRCUIT FAULT

    Directory of Open Access Journals (Sweden)

    V.Y. Tchaban

    2013-10-01

    Full Text Available In the paper, a formula is introduced to calculate electric motor supply unit voltage under feeding by a common transformer in the condition of a phase-to-phase short-circuit. The formula is used in every time step of electromechanical state equations integration.

  2. 76 FR 66333 - Carolina Power & Light Company, H.B. Robinson Steam Electric Plant, Unit No. 2; Environmental...

    Science.gov (United States)

    2011-10-26

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-261; NRC-2011-0247] Carolina Power & Light Company, H.B. Robinson Steam Electric Plant, Unit No. 2; Environmental Assessment and Finding of No Significant... Facility Operating License No. DPR-23, issued to Carolina Power & Light Company (the licensee), for...

  3. Cogeneration of heat and electricity from rape oil with a little CHP unit in a car wash

    International Nuclear Information System (INIS)

    Pilz, H.D.; Thomas, S.; Zeilinger, J.

    2002-01-01

    Environmentally friendly energy supply system for smaller houses is described. In Elsbett system the so-called multi fuel engine starts the combined electricity and heat production unit. In such a system one can use also natural fuels, animal oils and fats besides heating oil. Therefore no additional CO 2 is produced, but it will be brought to the balanced natural circle

  4. Radioactive waste shipments to Hanford Retrievable Storage from the General Electric Vallecitos Nuclear Center, Pleasanton, California

    International Nuclear Information System (INIS)

    Vejvoda, E.J.; Pottmeyer, J.A.; DeLorenzo, D.S.; Weyns-Rollosson, M.I.; Duncan, D.R.

    1993-10-01

    During the next two decades the transuranic (TRU) wastes now stored in the burial trenches and storage facilities at the Hanford Site are to be retrieved, processed at the Waste Receiving and Processing Facility, and shipped to the Waste Isolation Pilot Plant near Carlsbad, New Mexico for final disposal. Approximately 3.8% of the TRU waste to be retrieved for shipment to WIPP was generated at the General Electric (GE) Vallecitos Nuclear Center (VNC) in Pleasanton, California and shipped to the Hanford Site for storage. The purpose of this report is to characterize these radioactive solid wastes using process knowledge, existing records, and oral history interviews. The waste was generated almost exclusively from the activities, of the Plutonium Fuels Development Laboratory and the Plutonium Analytical Laboratory. Section 2.0 provides further details of the VNC physical plant, facility operations, facility history, and current status. The solid radioactive wastes were associated with two US Atomic Energy Commission/US Department of Energy reactor programs -- the Fast Ceramic Reactor (FCR) program, and the Fast Flux Test Reactor (FFTR) program. These programs involved the fabrication and testing of fuel assemblies that utilized plutonium in an oxide form. The types and estimated quantities of waste resulting from these programs are discussed in detail in Section 3.0. A detailed discussion of the packaging and handling procedures used for the VNC radioactive wastes shipped to the Hanford Site is provided in Section 4.0. Section 5.0 provides an in-depth look at this waste including the following: weight and volume of the waste, container types and numbers, physical description of the waste, radiological components, hazardous constituents, and current storage/disposal locations

  5. Radioactive waste shipments to Hanford Retrievable Storage from the General Electric Vallecitos Nuclear Center, Pleasanton, California

    Energy Technology Data Exchange (ETDEWEB)

    Vejvoda, E.J.; Pottmeyer, J.A.; DeLorenzo, D.S.; Weyns-Rollosson, M.I. [Los Alamos Technical Associates, Inc., NM (United States); Duncan, D.R. [Westinghouse Hanford Co., Richland, WA (United States)

    1993-10-01

    During the next two decades the transuranic (TRU) wastes now stored in the burial trenches and storage facilities at the Hanford Site are to be retrieved, processed at the Waste Receiving and Processing Facility, and shipped to the Waste Isolation Pilot Plant near Carlsbad, New Mexico for final disposal. Approximately 3.8% of the TRU waste to be retrieved for shipment to WIPP was generated at the General Electric (GE) Vallecitos Nuclear Center (VNC) in Pleasanton, California and shipped to the Hanford Site for storage. The purpose of this report is to characterize these radioactive solid wastes using process knowledge, existing records, and oral history interviews. The waste was generated almost exclusively from the activities, of the Plutonium Fuels Development Laboratory and the Plutonium Analytical Laboratory. Section 2.0 provides further details of the VNC physical plant, facility operations, facility history, and current status. The solid radioactive wastes were associated with two US Atomic Energy Commission/US Department of Energy reactor programs -- the Fast Ceramic Reactor (FCR) program, and the Fast Flux Test Reactor (FFTR) program. These programs involved the fabrication and testing of fuel assemblies that utilized plutonium in an oxide form. The types and estimated quantities of waste resulting from these programs are discussed in detail in Section 3.0. A detailed discussion of the packaging and handling procedures used for the VNC radioactive wastes shipped to the Hanford Site is provided in Section 4.0. Section 5.0 provides an in-depth look at this waste including the following: weight and volume of the waste, container types and numbers, physical description of the waste, radiological components, hazardous constituents, and current storage/disposal locations.

  6. The effect of electrical stimulation of the corticospinal tract on motor units of the human biceps brachii

    DEFF Research Database (Denmark)

    Petersen, Nicolas Caesar; Taylor, Janet L; Gandevia, Simon C

    2002-01-01

    In healthy human subjects, descending motor pathways including the corticospinal tract were stimulated electrically at the level of the cervicomedullary junction to determine the effects on the discharge of motoneurones innervating the biceps brachii. Post-stimulus time histograms (PSTHs) were...... constructed for 15 single motor units following electrical stimulation of the corticospinal tract and for 11 units following electrical stimulation of large diameter afferents at the brachial plexus. Responses were assessed during weak voluntary contraction. Both types of stimulation produced a single peak...... in the two conditions when the intensity of the stimulation was adjusted so that responses of the same size could be compared. Estimates of the descending conduction velocity and measurements of presumed peripheral conduction time suggest that there is less than 0.5 ms for spinal events (including synaptic...

  7. Day surgery: Results after restructuration of a university public general surgery unit.

    Science.gov (United States)

    Gaucher, S; Cappiello, F; Bouam, S; Damardji, I; Aissat, A; Boutron, I; Béthoux, J P

    2013-06-01

    Nowadays, in France, development of the ambulatory surgery has stalled. This is probably related to the fact that ambulatory surgery is restricted by the law to the "day surgery" in 12 hours, and only 17 procedures are referenced for this surgery. Thus, conventional hospitalization remained the rule after surgery. In January 2010, our university general surgery unit was restructured. It evolved from a conventional unit to a predominantly ambulatory unit. Otherwise, our unit adjoins a hotel, even inside our institution, which accommodates patients, patient visitors and tourists. The aim of this retrospective study was to compare the postoperative accommodation modalities between two groups of patients. The first group consisted of patients admitted before January 2010, at the time of conventional activity, whereas the second group consisted of patients admitted after January 2010 in a restructured unit. Inclusion of patients admitted from April 1, 2008 to March 31, 2009 (conventional hospitalization period) and from April 1, 2010 to March 31, 2011 (ambulatory management period), scheduled for one single surgical procedure excluding emergency. A total of 360 patients were retained: 229 for the conventional period and 131 for the ambulatory period, with a median age of 55 (range 15-87). No statistically significant difference was noted between the two groups as concerned median age, gender or ASA status. The number of postoperative nights varied significantly between the two groups with a mean of 3.8 nights (median three nights, range 0-32) for the conventional period versus 0.4 nights (median 0 night, range 0-10) for the ambulatory period (Plegal period of 12 hours to 24 hours in order to expand the list of the referenced procedures. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  8. The Slavery in Circassia and the United States (1850–1860-ies years: General and Special

    Directory of Open Access Journals (Sweden)

    Mikhal Smigel

    2016-12-01

    Full Text Available The article provides a comparative analysis of slavery in Circassia and in the territory of the slave South in the United States in 1850–1860-ies years in the context of the fight against the slave trade and slavery in the world. The article discusses the Russian-American general trends for the prohibition of slavery and the slave trade. Among the materials are Russian and foreign archival sources, documents of personal origin (memoirs, diaries of travelers as well as scientific research. The methodological basis of historical-comparative study are the principles of objectivity and historicism, suggesting an unbiased approach to the analysis of the studied problems, a critical attitude to the sources, making judgments as a result of the analysis of a set of facts, and displays the slave of phenomena in the development and the context of the historical situation. In conclusion, the authors note that slavery and the slave position in the United States and the Circassia had their differences in 1850–1860-ies. Such differences included the inability of the transition to the United States from the status of a slave in the state of the dependent peasant, which was the norm in Circassia. In the United States the slaves were brought from outside, while in Circassia the slavery occurred in the region, mainly by trapping. At the root of discrimination in the United States was the racial principle, in Circassia this is based on the religious principle. The position of slaves had their similarities. A slave was powerless property of his master, there were certain unwritten rules governing the relationship, slave owners were reluctant to bring slaves to the extreme and etc. The important similarity between the US and Circassia was the presence of their territories with a strong slave system, where slaves constituted more than 30 % of the population. In the US, it was the territory of the slave-holding South, and in Circassia – the slaveholding Ubykhia.

  9. Discrete-Event Execution Alternatives on General Purpose Graphical Processing Units

    International Nuclear Information System (INIS)

    Perumalla, Kalyan S.

    2006-01-01

    Graphics cards, traditionally designed as accelerators for computer graphics, have evolved to support more general-purpose computation. General Purpose Graphical Processing Units (GPGPUs) are now being used as highly efficient, cost-effective platforms for executing certain simulation applications. While most of these applications belong to the category of time-stepped simulations, little is known about the applicability of GPGPUs to discrete event simulation (DES). Here, we identify some of the issues and challenges that the GPGPU stream-based interface raises for DES, and present some possible approaches to moving DES to GPGPUs. Initial performance results on simulation of a diffusion process show that DES-style execution on GPGPU runs faster than DES on CPU and also significantly faster than time-stepped simulations on either CPU or GPGPU.

  10. Statement to the 47th session of the United Nations General Assembly

    International Nuclear Information System (INIS)

    Blix, H.

    1993-01-01

    IAEA Director General, Hans Blix, in his statement to the 47th session of the United Nations General Assembly on 21 October 1992, reminded that 1992 marks the fiftieth anniversary of controlled nuclear fission and the thirty-fifth anniversary of the IAEA. He specially commented on the various measures taken during the past year to strengthen the IAEA's safeguards system as a part of the challenge to reduce the risk of a further spread of nuclear weapons. He also discussed the role of the IAEA in the fields of nuclear safety, nuclear waste, transfer of technology and assistance to developing countries and the financing and management of the Agency within the UN system

  11. Challenges and Experiences with Electric Propulsion Transit Buses in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Eudy, L.; Gifford, M.

    2003-11-01

    Document provides background for transit agencies and fleets that are considering electric propulsion technologies. It tells them what to expect and plan for when implementing vehicles with electric propulsion systems.

  12. An electrical load measurements dataset of United Kingdom households from a two-year longitudinal study.

    Science.gov (United States)

    Murray, David; Stankovic, Lina; Stankovic, Vladimir

    2017-01-05

    Smart meter roll-outs provide easy access to granular meter measurements, enabling advanced energy services, ranging from demand response measures, tailored energy feedback and smart home/building automation. To design such services, train and validate models, access to data that resembles what is expected of smart meters, collected in a real-world setting, is necessary. The REFIT electrical load measurements dataset described in this paper includes whole house aggregate loads and nine individual appliance measurements at 8-second intervals per house, collected continuously over a period of two years from 20 houses. During monitoring, the occupants were conducting their usual routines. At the time of publishing, the dataset has the largest number of houses monitored in the United Kingdom at less than 1-minute intervals over a period greater than one year. The dataset comprises 1,194,958,790 readings, that represent over 250,000 monitored appliance uses. The data is accessible in an easy-to-use comma-separated format, is time-stamped and cleaned to remove invalid measurements, correctly label appliance data and fill in small gaps of missing data.

  13. The impact of federal incentives on the adoption of hybrid electric vehicles in the United States

    International Nuclear Information System (INIS)

    Jenn, Alan; Azevedo, Inês L.; Ferreira, Pedro

    2013-01-01

    Starting in 2004, the federal government in the United States offered several nationwide incentives to consumers to increase the adoption of hybrid electric vehicles. This study assesses the effectiveness of the Energy Policy Act of 2005 in this regard using econometric methods and data between 2000 and 2010. Our model accounts for network externalities by using lagged sales as an independent variable. This approach helps to capture the exponential initial growth associated with the diffusion of new technologies and avoids overestimating the effect of the policy incentives. Our results show that the Energy Policy Act of 2005 increased the sales of hybrids from 3% to 20% depending on the vehicle model considered. In addition, we find that this incentive is only effective when the amount provided is sufficiently large. - Highlights: • We collected data on monthly car sales by vehicle model for 11 years. • Econometric methods are used to model vehicle sales. • Inclusion of a lagged dependent variable is employed to control for natural growth. • Direct monetary incentives are found to be statistically insignificant. • Macro-effects of unemployment and gas prices are important for vehicle sales

  14. An electrical load measurements dataset of United Kingdom households from a two-year longitudinal study

    Science.gov (United States)

    Murray, David; Stankovic, Lina; Stankovic, Vladimir

    2017-01-01

    Smart meter roll-outs provide easy access to granular meter measurements, enabling advanced energy services, ranging from demand response measures, tailored energy feedback and smart home/building automation. To design such services, train and validate models, access to data that resembles what is expected of smart meters, collected in a real-world setting, is necessary. The REFIT electrical load measurements dataset described in this paper includes whole house aggregate loads and nine individual appliance measurements at 8-second intervals per house, collected continuously over a period of two years from 20 houses. During monitoring, the occupants were conducting their usual routines. At the time of publishing, the dataset has the largest number of houses monitored in the United Kingdom at less than 1-minute intervals over a period greater than one year. The dataset comprises 1,194,958,790 readings, that represent over 250,000 monitored appliance uses. The data is accessible in an easy-to-use comma-separated format, is time-stamped and cleaned to remove invalid measurements, correctly label appliance data and fill in small gaps of missing data.

  15. Development of a tilting system for electric multiple unit to speed up on conventional lines

    International Nuclear Information System (INIS)

    Seo, Sung Il; Kim, Nam Po; Lee, Soo Gil; Kim, Seok Won

    2008-01-01

    An advanced tilting system for KTT (Korean Tilting Train) was developed and a performance test of the system has been completed. KTT has been constructed to speed up and promise a significant enhancement in service quality on a conventional line. KTT is an electric multiple unit composed of 6 cars running at the design speed of 200 km/h. The tilting system is the core technology of KTT and combined with the conventional bogie system. It has a self-steering mechanism and a swing link. The self-steering mechanism of Z-bar type is free to rotate on the curve and stable to run on a straight line. The swing link mechanism of the bolster enables the carbody to tilt up to 8 .deg.. A tilting control system detects a curve with sensors and commands the electro-mechanical actuators to move the bolster through the computer network system. GPS collaborates with the tilting system to perceive the curve previously and enables gradual tilting so as not to violate passenger comfort. The performance of the tilting system has been verified by a trial test running of KTT on a commercial conventional line. The tilting system is ready for commercial use

  16. Selective fatigue of fast motor units after electrically elicited muscle contractions.

    Science.gov (United States)

    Hamada, Taku; Kimura, Tetsuya; Moritani, Toshio

    2004-10-01

    The aim of the present study was to elucidate the electrophysiological manifestations of selective fast motor unit (MU) activation by electrical stimulation (ES) of knee extensor muscles. In six male subjects, test contraction measurement at 40% maximal voluntary contraction (MVC) was performed before and at every 5 min (5, 10, 15 and 20 min) during 20-min low intensity intermittent exercise of either ES or voluntary contractions (VC) at 10% MVC (5-s isometric contraction and 5-s rest cycles). Both isolated intramuscular MU spikes obtained from three sets of bipolar fine-wire electrodes and surface electromyogram (EMG) were simultaneously recorded and were analyzed by means of a computer-aided intramuscular spike amplitude-frequency analysis and frequency power spectral analysis, respectively. Results indicated that mean MU spike amplitude, particularly those MUs with relatively large amplitude, was significantly reduced while those MUs with small spike amplitude increased their firing rate during the 40% MVC test contraction after the ES. This was accompanied by the increased amplitude of surface EMG (rmsEMG). However, no such significant changes in the intramuscular and surface EMGs were observed after VC. These findings indicated differential MU activation patterns in terms of MU recruitment and rate coding characteristics during ES and VC, respectively. Our data strongly suggest the possibility of "an inverse size principle" of MU recruitment during ES.

  17. Electric power supply and demand for the contiguous United States, 1980-1989

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-06-01

    A limited review is presented of the outlook for the electric power supply and demand during the period 1980 to 1989. Only the adequacy and reliability aspects of bulk electric power supply in the contiguous US are considered. The economic, financial and environmental aspects of electric power system planning and the distribution of electricity (below the transmission level) are topics of prime importance, but they are outside the scope of this report.

  18. Design and Application of a Power Unit to Use Plug-In Electric Vehicles as an Uninterruptible Power Supply

    Directory of Open Access Journals (Sweden)

    Gorkem Sen

    2016-03-01

    Full Text Available Grid-enabled vehicles (GEVs such as plug-in electric vehicles present environmental and energy sustainability advantages compared to conventional vehicles. GEV runs solely on power generated by its own battery group, which supplies power to its electric motor. This battery group can be charged from external electric sources. Nowadays, the interaction of GEV with the power grid is unidirectional by the charging process. However, GEV can be operated bi-directionally by modifying its power unit. In such operating conditions, GEV can operate as an uninterruptible power supply (UPS and satisfy a portion or the total energy demand of the consumption center independent from utility grid, which is known as vehicle-to-home (V2H. In this paper, a power unit is developed for GEVs in the laboratory to conduct simulation and experimental studies to test the performance of GEVs as a UPS unit in V2H mode at the time of need. The activation and deactivation of the power unit and islanding protection unit are examined when energy is interrupted.

  19. Coal-Powered Electric Generating Unit Efficiency and Reliability Dialogue: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Emmanuel [Energetics, Inc., Columbia, MD (United States)

    2018-02-01

    Coal continues to play a critical role in powering the Nation’s electricity generation, especially for baseload power plants. With aging coal generation assets facing decreased performance due to the state of the equipment, and with challenges exacerbated by the current market pressures on the coal sector, there are opportunities to advance early-stage technologies that can retrofit or replace equipment components. These changes will eventually result in significant improvements in plant performance once further developed and deployed by industry. Research and development in areas such as materials, fluid dynamics, fuel properties and preparation characteristics, and a new generation of plant controls can lead to new components and systems that can help improve the efficiency and reliability of coal-fired power plants significantly, allowing these assets to continue to provide baseload power. Coal stockpiles at electricity generation plants are typically large enough to provide 30 to 60 days of power prior to resupply—significantly enhancing the stability and reliability of the U.S. electricity sector. Falling prices for non-dispatchable renewable energy and mounting environmental regulations, among other factors, have stimulated efforts to improve the efficiency of these coal-fired electric generating units (EGUs). In addition, increased reliance on natural gas and non-dispatchable energy sources has spurred efforts to further increase the reliability of coal EGUs. The Coal Powered EGU Efficiency and Reliability Dialogue brought together stakeholders from across the coal EGU industry to discuss methods for improvement. Participants at the event reviewed performance-enhancing innovations in coal EGUs, discussed the potential for data-driven management practices to increase efficiency and reliability, investigated the impacts of regulatory compliance on coal EGU performance, and discussed upcoming challenges for the coal industry. This report documents the key

  20. Prediktor Stres Keluarga Akibat Anggota Keluarganya Dirawat di General Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Zahara Farhan

    2014-09-01

    Full Text Available Hospitalization of family member in intensive care can be a trigger of stress in the family. Several factors which could create a stressful situation in a family are changes of environment, rules in the ward, changes of family emotional status, changes of family member roles, changes of daily activities, changes in financial situation and health care workers' attitude when giving information on patient’s health status. This study was a cross-sectional study. The number of subjects included in this study were 60 representing families whose member was hospitalized in the General Intensive Care Unit (GICU of Dr. Hasan Sadikin General Hospital (RSHS Bandung during the period of March to May 2012. The sampling technique used was purposive sampling. The instrument used to measure the stress predictors was developed based on theoretical review and modification of family inventory live events standard instrument. Meanwhile, the instrument used for measuring the family stress was the Depression Anxiety Stress Scale 42. Data were analyzed using chi-square test and logistic regression. The results of this study showed environmental changes, rules in the ward, emotional status changes and daily activity changes significantly corelated with stress (p value 0.01, 0.04 and 0.03, respectively. In conclusion, none of the 6 family predictors dominantly predicts stress. Nurses are expected to do early detection on psychological family problems in intensive care unit and optimize supportive-educative treatment in the form of counseling for family members.

  1. Dysphagia referrals to a district general hospital gastroenterology unit: hard to swallow.

    Science.gov (United States)

    Melleney, Elizabeth Mary-Ann; Subhani, Javaid Mohammed; Willoughby, Charles Peter

    2004-01-01

    The aim of our study was to audit dysphagia referrals received by a specialist gastroenterology unit during an entire year. We used a prospective audit carried out over a 12-month period at the District General Hospital gastroenterology unit. The audit included 396 consecutive patients who were referred with swallowing difficulties. We found that 60 referrals (15.2%) were inaccurate and the patients had no swallowing problem. Of the 336 patients with genuine dysphagia, only 29 (8.6%) were new cancer cases. The large majority of subjects had benign disease mostly related to acid reflux. Weight loss was significantly associated with malignancy but also occurred in one third of patients with reflux alone. The temporal pattern of dysphagia was not significantly predictive of cancer. All the cancer patients were above the age of 50 years. Although patients were in general assessed rapidly after hospital referral, the productivity, in terms of early tumor diagnosis, was extremely low. We conclude that there is a substantial rate of inaccurate referrals of dysphagia patients. Most true cases of swallowing difficulty relate to benign disease. Even the devotion of considerable resources to the early diagnosis of esophago gastric malignancy in an attempt to conform with best practice guidelines results in a very low success rate in terms of the detection of potentially curable tumors.

  2. The Research of Utilization Hours of Coal-Fired Power Generation Units Based on Electric Energy Balance

    Science.gov (United States)

    Liu, Junhui; Yang, Jianlian; Wang, Jiangbo; Yang, Meng; Tian, Chunzheng; He, Xinhui

    2018-01-01

    With grid-connected scale of clean energy such as wind power and photovoltaic power expanding rapidly and cross-province transmission scale being bigger, utilization hours of coal-fired power generation units become lower and lower in the context of the current slowdown in electricity demand. This paper analyzes the influencing factors from the three aspects of demand, supply and supply and demand balance, and the mathematical model has been constructed based on the electric energy balance. The utilization hours of coal-fired power generation units have been solved considering the relationship among proportion of various types of power installed capacity, the output rate and utilization hours. By carrying out empirical research in Henan Province, the utilization hours of coal-fired units of Henan Province in 2020 has been achieved. The example validates the practicability and the rationality of the model, which can provide a basis for the decision-making for coal-fired power generation enterprises.

  3. Low-cost general purpose spectral display unit using an IBM PC

    International Nuclear Information System (INIS)

    Robinson, S.L.

    1985-10-01

    Many physics experiments require acquisition and analysis of spectral data. commercial minicomputer-based multichannel analyzers collect detected counts at various energies, create a histogram of the counts in memory, and display the resultant spectra. They acquire data and provide the user-to-display interface. The system discussed separates functions into the three modular components of data acquisition, storage, and display. This decoupling of functions allows the experimenter to use any number of detectors for data collection before forwarding up to 64 spectra to the display unit, thereby increasing data throughput over that available with commercial systems. An IBM PC was chosen for the low-cost, general purpose display unit. Up to four spectra may be displayed simultaneously in different colors. The histogram saves 1024 channels per detector, 640 of which may be distinctly displayed per spectra. The IEEE-488 standard provides the data path between the IBM PC and the data collection unit. Data is sent to the PC under interrupt control, using direct memory access. Display manipulations available via keyboard are also discussed

  4. A low-cost general purpose spectral display unit using an IBM PC

    International Nuclear Information System (INIS)

    Robinson, S.L.

    1986-01-01

    Many physics experiments require acquisition and analysis of spectral data. Commercial minicomputer-based multichannel analyzers collect detected counts at various energies, create a histogram of the counts in memory, and display the resultant spectra. They acquire data and provide the user-to-display interface. The system discussed separates functions into the three modular components of data acquisition, storage, and display. This decoupling of functions allows the experimenter to use any number of detectors for data collection before forwarding up to 64 spectra to the display unit, thereby increasing data throughput over that available with commercial systems. An IBM PC was chosen for the low-cost, general purpose display unit. Up to four spectra may be displayed simultaneously in different colors. The histogram saves 1024 channels per detector, 640 of which may be distinctly displayed per spectra. The IEEE-488 standard provides the data path between the IBM PC and the data collection unit. Data is sent to the PC under interrupt control, using direct memory access. Display manipulations available via keyboard are also discussed

  5. Time horizons and electricity futures: An application of Nicholas Georgescu-Roegen's general theory of economic production

    Energy Technology Data Exchange (ETDEWEB)

    Farrell, Katharine N. [Department of Economics, Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318 Leipzig (Germany); Gibson Institute for Land, Food and Environment, Queen' s University of Belfast, Northern Ireland (United Kingdom); Mayumi, Kozo [Faculty of Integrated Arts and Sciences, The University of Tokushima (Japan)

    2009-03-15

    This paper reports theoretical economic production work and uses electricity futures trading to illustrate its argument. The focus is relationships between time, production and tradition both in Nicholas Georgescu-Roegen's analytical representation of the production process (i.e., flow/fund model) and in his dialectical scheme dealing with the evolutionary changes in the economic process. Our main arguments are (1) the flow/fund model is designed to be employed in conjunction with attention to how the boundaries of a given process are determined and (2) process boundaries are dialectical distinctions - between process and not-process - that are strongly related to time and tradition. We propose that Georgescu-Roegen's The Entropy Law and the Economic Process is best understood as the elaboration of a general theory of economic production and we developed two conceptual tools (time {open_square} and meta-funds), both of which are related to the dialectical distinction between process and not-process, which we use to operationalise this general theory. Finally, we demonstrate that, although trading in electricity futures is surprising if one uses a stock/flow vs services distinction (because electricity supply is classed as a service) it appears perfectly logical under Georgescu-Roegen's general theory: shortening time horizons, combined with a shift in the relationship between raw fuel supplies and power production procedures, lead to a shift in the status of electricity supply, from fund to flow. (author)

  6. General classical and quantum-mechanical description of magnetic resonance: an application to electric-dipole-moment experiments

    Energy Technology Data Exchange (ETDEWEB)

    Silenko, Alexander J. [Belarusian State University, Research Institute for Nuclear Problems, Minsk (Belarus); Joint Institute for Nuclear Research, Bogoliubov Laboratory of Theoretical Physics, Dubna (Russian Federation)

    2017-05-15

    A general theoretical description of a magnetic resonance is presented. This description is necessary for a detailed analysis of spin dynamics in electric-dipole-moment experiments in storage rings. General formulas describing a behavior of all components of the polarization vector at the magnetic resonance are obtained for an arbitrary initial polarization. These formulas are exact on condition that the nonresonance rotating field is neglected. The spin dynamics is also calculated at frequencies far from resonance with allowance for both rotating fields. A general quantum-mechanical analysis of the spin evolution at the magnetic resonance is fulfilled and the full agreement between the classical and quantum-mechanical approaches is shown. Quasimagnetic resonances for particles and nuclei moving in noncontinuous perturbing fields of accelerators and storage rings are considered. Distinguishing features of quasimagnetic resonances in storage ring electric-dipole-moment experiments are investigated in detail. The exact formulas for the effect caused by the electric dipole moment are derived. The difference between the resonance effects conditioned by the rf electric-field flipper and the rf Wien filter is found and is calculated for the first time. The existence of this difference is crucial for the establishment of a consent between analytical derivations and computer simulations and for checking spin tracking programs. The main systematical errors are considered. (orig.)

  7. Hazardous Waste Cleanup: General Electric – Main Plant Site in Schenectady, New York

    Science.gov (United States)

    GE purchased the property at Genesee Street in 1951 and constructed a manufacturing plant that produced a variety of electrical components including radar equipment, printed circuit boards and high voltage semiconductors. In January 1986, Powerex, Inc., ac

  8. Hazardous Waste Cleanup: General Electric - Auburn Plant in Auburn, New York

    Science.gov (United States)

    GE purchased the property at Genesee Street in 1951 and constructed a manufacturing plant that produced a variety of electrical components including radar equipment, printed circuit boards and high voltage semiconductors. In January 1986, Powerex, Inc.,

  9. 76 FR 77022 - In the Matter of Carolina Power & Light Company, H.B. Robinson Steam Electric Plant, Unit No. 2...

    Science.gov (United States)

    2011-12-09

    ... and 72-3] In the Matter of Carolina Power & Light Company, H.B. Robinson Steam Electric Plant, Unit No. 2, H. B. Robinson Steam Electric Plant, Unit 2, Independent Spent Fuel Storage Installation; Order Approving Indirect Transfer of Control of Licenses I. Carolina Power & Light Company (CP&L, the licensee) is...

  10. Converted vehicle for battery electric drive. Aspects on the design of the software-driven vehicle control unit

    Energy Technology Data Exchange (ETDEWEB)

    Giessler, Martin; Paul, Jens; Gauterin, Frank [Karlsruher Institut fuer Technologie (KIT), Karlsruhe (Germany). Inst. fuer Fahrzeugsystemtechnik (FAST); Fritz, Alexander; Sander, Oliver; Mueller-Glaser, Klaus D. [Karlsruher Institut fuer Technologie (KIT), Karlsruhe (Germany). Inst. fuer Technik der Informationsverarbeitung (ITIV)

    2012-11-01

    At the Karlsruher Institute of Technology (KIT) a vehicle was converted for full battery electric drive within a cooperation of several faculties under the direction of the chair of vehicle technology. Within this paper the developed software to control the main functions of the vehicle will be presented and potentials to increase the energy efficiency will be discussed. The software based vehicle control unit is the central control unit to realize drivers command with respect to the system parameters, which are important for safety, dynamics, range and comfort of the vehicle. The structure of the software architecture, the interaction with the main electric vehicle specific control units and components and the main implemented functions will be described within this paper. The converted vehicle consists mainly of one electric motor with water cooled power electronics that drives the front axle, 21 battery modules controlled and managed by the battery management system, one on board charging device and an universal control unit. Not only strategies for power recovery while braking, but also strategies for driving and operation can help increase the energy efficiency. Select measures to recover and safe energy are also shown. (orig.)

  11. The environmental and efficiency effects of restructuring on the electric power sector in the United States. An empirical analysis

    International Nuclear Information System (INIS)

    Sharabaroff, Alexander; Boyd, Roy; Chimeli, Ariaster

    2009-01-01

    Recent measures to restructure the electric power sector in different US states have raised the interest of policy makers, commentators, and the general public as to the actual impact of restructuring on both the economy and the environment. This paper focuses on two aspects of restructuring, namely its potential impact on the efficiency of electricity generation and air pollution. Our empirical results suggest that restructuring contributes to improved efficiency of electricity generation and better air quality through reduced electricity-induced sulfur dioxide (SO 2 ) and carbon dioxide (CO 2 ) emissions, although no effect was found for emissions of nitrous oxides (NO x ). These results, in turn could have important implications for policy in this area. (author)

  12. Patient examinations using electrical impedance tomography—sources of interference in the intensive care unit

    International Nuclear Information System (INIS)

    Frerichs, Inéz; Pulletz, Sven; Elke, Gunnar; Gawelczyk, Barbara; Frerichs, Alexander; Weiler, Norbert

    2011-01-01

    Electrical impedance tomography (EIT) is expected to become a valuable tool for monitoring mechanically ventilated patients due to its ability to continuously assess regional lung ventilation and aeration. Several sources of interference with EIT examinations exist in intensive care units (ICU). Our objectives are to demonstrate how some medical nursing and monitoring devices interfere with EIT measurements and modify the EIT scans and waveforms, which approaches can be applied to minimize these effects and how possible misinterpretation can be avoided. We present four cases of EIT examinations of adult ICU patients. Two of the patients were subjected to pulsation therapy using a pulsating air suspension mattress while being ventilated by high-frequency oscillatory or conventional pressure-controlled ventilation, respectively. The EIT signal modulation synchronous with the occurrence of the pulsating wave was 2.3 times larger than the periodic modulation synchronous with heart rate and high-frequency oscillations. During conventional ventilation, the pulsating mattress induced an EIT signal fluctuation with a magnitude corresponding to about 20% of the patient's tidal volume. In the third patient, interference with EIT examination was caused by continuous cardiac output monitoring. The last patient's examination was disturbed by impedance pneumography when excitation currents of similar frequency to EIT were used. In all subjects, the generation of functional EIT scans was compromised and interpretation of regional ventilation impossible. Discontinuation of pulsation therapy and of continuous cardiac output and impedance respiration monitoring immediately improved the EIT signal and scan quality. Offline processing of the disturbed data using frequency filtering enabled partial retrieval of relevant information. We conclude that thoracic EIT examinations in the ICU require cautious interpretation because of possible mechanical and electromagnetic

  13. Efficacy of neuromuscular electrical stimulation in patients with COPD followed in intensive care unit.

    Science.gov (United States)

    Akar, Olcay; Günay, Ersin; Sarinc Ulasli, Sevinc; Ulasli, Alper Murat; Kacar, Emre; Sariaydin, Muzaffer; Solak, Özlem; Celik, Sefa; Ünlü, Mehmet

    2017-11-01

    Serious problems on muscle strength and functional status can be seen in bedridden-patients with chronic obstructive pulmonary diseases (COPD) receiving mechanical ventilation. We aimed to investigate the impact of active extremity mobilization and neuromuscular electrical stimulation (NMES) on weaning processes, discharge from hospital and inflammatory mediators in COPD patients receiving mechanical ventilation. Thirty conscious COPD patients (F/M:15/15) hospitalized in the intensive care unit (ICU) with diagnosis of respiratory failure were enrolled to this study. Patients were randomized into three groups, including 10 patients for each. Active extremity-exercise training and NMES were applied to Group-1, only NMES was applied to Group-2 and active extremity exercise training was applied to Group-3. Muscle strengths, mobilization duration and weaning situation were evaluated. Serum cytokine levels were evaluated. Lower extremity muscle-strength was significantly improved in Group-1 (from 3.00 to 5.00, P = 0.014) and 2 (from 4.00 to 5.00, P = 0.046). Upper extremity muscle strength was also significantly improved in all three groups (from 4.00 to 5.00 for all groups, P = 0.038, P = 0.046 and P = 0.034, respectively). Duration of mobilization and discharge from the ICU were similar among groups. There was a significant decrease in serum interleukin (IL)-6 level in Group-1 and in serum IL-8 level in Group-1 and Group-2 after rehabilitation. This study indicates that pulmonary rehabilitation can prevent loss of muscle strength in ICU. Nevertheless, we consider that further studies with larger populations are needed to examine the impact of NMES and/or active and passive muscle training in bedridden ICU patients who are mechanically ventilated. © 2015 John Wiley & Sons Ltd.

  14. Wind energy as a significant source of electricity for the United States

    International Nuclear Information System (INIS)

    Nix, R.G.

    1996-06-01

    This paper discusses wind energy and its potential to significantly impact the generation of electricity within the US. The principles and the equipment used to convert wind energy to electricity are described, as is the status of current technology. Markets and production projections are given. There is discussion of the advances required to reduce the selling cost of electricity generated from the wind from today's price of about $0.05 per kilowatt-hour to full cost-competitiveness with gas- and coal-based electricity

  15. General Purpose Graphics Processing Unit Based High-Rate Rice Decompression and Reed-Solomon Decoding

    Energy Technology Data Exchange (ETDEWEB)

    Loughry, Thomas A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-01

    As the volume of data acquired by space-based sensors increases, mission data compression/decompression and forward error correction code processing performance must likewise scale. This competency development effort was explored using the General Purpose Graphics Processing Unit (GPGPU) to accomplish high-rate Rice Decompression and high-rate Reed-Solomon (RS) decoding at the satellite mission ground station. Each algorithm was implemented and benchmarked on a single GPGPU. Distributed processing across one to four GPGPUs was also investigated. The results show that the GPGPU has considerable potential for performing satellite communication Data Signal Processing, with three times or better performance improvements and up to ten times reduction in cost over custom hardware, at least in the case of Rice Decompression and Reed-Solomon Decoding.

  16. General purpose graphic processing unit implementation of adaptive pulse compression algorithms

    Science.gov (United States)

    Cai, Jingxiao; Zhang, Yan

    2017-07-01

    This study introduces a practical approach to implement real-time signal processing algorithms for general surveillance radar based on NVIDIA graphical processing units (GPUs). The pulse compression algorithms are implemented using compute unified device architecture (CUDA) libraries such as CUDA basic linear algebra subroutines and CUDA fast Fourier transform library, which are adopted from open source libraries and optimized for the NVIDIA GPUs. For more advanced, adaptive processing algorithms such as adaptive pulse compression, customized kernel optimization is needed and investigated. A statistical optimization approach is developed for this purpose without needing much knowledge of the physical configurations of the kernels. It was found that the kernel optimization approach can significantly improve the performance. Benchmark performance is compared with the CPU performance in terms of processing accelerations. The proposed implementation framework can be used in various radar systems including ground-based phased array radar, airborne sense and avoid radar, and aerospace surveillance radar.

  17. Competition and regulation in the European network industries. From general case to the case of electricity

    International Nuclear Information System (INIS)

    Jonquieres, F.

    1995-01-01

    The paper focuses on the institutional arrangements present situation in the European Electricity Supply Industry, which is characterized by its diversity. There is unquestionably, a trend to put pressure on the national electricity systems by the European Union organisms to accept the unbundling, Third Party Access to the network, deregulation etc. An opposing reaction appears, trying to underline the potential important drawbacks of such a trend. The conclusion of the author can be summarised as follows: Competition at the generation level? Yes[ Access to the network ? No[ (author)

  18. Review of paediatric cardiology services in district general hospitals in the United Kingdom.

    Science.gov (United States)

    Andrews, Hannah; Singh, Yogen

    2016-03-01

    Following the Safe and Sustainable review of Paediatric Services in 2012/2013, National Health Service England recommended that local paediatric cardiology services should be provided by specially trained paediatricians with expertise in cardiology in all non-specialist hospitals. To understand the variation in local paediatric cardiology services provided across district general hospitals in the United Kingdom. An internet-based questionnaire was sent out via the Paediatrician with Expertise in Cardiology Special Interest Group and the Neonatologists with Interest in Cardiology and Haemodynamics contact databases and the National Health Service directory. Non-responders were followed-up via telephone. The response rate was 80% (141 of 177 hospitals), and paediatricians with expertise in cardiology were available in 68% of those. Local cardiology clinics led by paediatricians with expertise in cardiology were provided in 96 hospitals (68%), whereas specialist outreach clinics were held in 123 centres (87%). A total of 11 hospitals provided neither specialist outreach clinics nor any local cardiology clinics led by paediatricians with expertise in cardiology. Paediatric echocardiography services were provided in 83% of the hospitals, 12-lead electrocardiogram in 96%, Holter electrocardiogram in 91%, and exercise testing in only 47% of the responding hospitals. Telemedicine facilities were established in only 52% of the centres, where sharing echocardiogram images via picture archiving and communication system was used most commonly. There has been a substantial increase in the availability of paediatricians with expertise in cardiology since 2008. Most of the hospitals are well-supported by specialist cardiology centres via outreach clinics; however, there remains significant variation in the local paediatric cardiology services provided across district general hospitals in the United Kingdom.

  19. Stress, coping, and general health of nurses who work in units that assist AIDS-carriers and patients with

    OpenAIRE

    Da Silva Britto, Eliane; Pimenta Carvalho, Ana Maria

    2008-01-01

    Based on Lazarus and Folkman’s theory about stress and coping, this research aimed at answering questions related to how nurses, who work in two specialized units of a general hospital, evaluate their working environment, their health and how they manage with stressing situations. In the unit of infectious diseases, the nurses’ evaluation of their working environment did not surpass the limits of what is considered as acceptable. In the unit of hematological alterations, the results showed hi...

  20. Current trends in endodontic treatment by general dental practitioners: report of a United States national survey.

    Science.gov (United States)

    Savani, Gina M; Sabbah, Wael; Sedgley, Christine M; Whitten, Brian

    2014-05-01

    In the United States almost 70% of root canal treatment (RCT) is performed by general dentists (GPs), yet little is known about their treatment protocols. A paper survey was mailed to 2000 United States GPs with questions about the types of endodontic cases treated, routine treatment protocols, use of newer technologies, and endodontic continuing education (CE). Completed surveys were returned by 479 respondents (24%). GPs who perform RCT (84%) reported providing anterior (99%), bicuspid (95%), and molar (62%) RCT and retreatment (18%). Rubber dam was used always (60%), usually (16%), sometimes (13%), and never (11%). Newer technologies used by GPs included digital radiography (72%), magnification (80%), electronic apex locator (70%), and nickel-titanium rotary instrumentation (74%). Compared with GPs with >20 years of experience, those in practice for ≤10 years were more likely to use rubber dam (P 20 years were more likely to perform retreatments (P 5 hours of CE were more likely to use rotary instrumentation (P irrigant activation devices (P 20 years. More experienced GPs were more likely to take on complicated cases than those with fewer years of practice. There was no association between hours of CE and compliance with rubber dam usage. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  1. Antimicrobial-resistant bacteria in a general intensive care unit in Saudi Arabia

    International Nuclear Information System (INIS)

    Nermin K. Saeed; Abdulmageed M. Kambal; Noura A. El-Khizzi

    2010-01-01

    To assess the prevalence of multi-drug resistant (MDR) bacteria causing infections in patients at the intensive care units (ICUs) of Riyadh Military Hospital (RMH), as well as their antimicrobial resistance patterns for one year. A retrospective, cohort investigation was performed. Laboratory records from January to December 2009 were studied for the prevalence of MDR Gram-negative and Gram-positive bacteria and their antimicrobial resistance in ICU patients from RMH, Riyadh, Kingdom of Saudi Arabia. A total of 1210 isolates were collected from various specimens such as: respiratory (469), blood (400), wound/tissue (235), urinary (56), nasal swabs (35), and cerebro-spinal fluid (15). Regardless of the specimen, there was a high rate of nosocomial MDR organisms isolated from patients enrolled in the General ICU (GICU) in Riyadh. Acinetobacter baumannii (A. baumannii) comprised 40.9%, Klebsiella pneumonia (K. pneumonia) - 19.4%, while Pseudomonas aeruginosa (P. aeruginosa) formed 16.3% of these isolates. The P. aeruginosa, A. baumannii, K. pneumoniae, Escherichia coli, Staphylococcus aureus (methycillin sensitive and methycillin resistant), and Staphylococccus coagulase negative are the most common isolates recovered from clinical specimens in the GICU of RMH. Respiratory tract specimens represented nearly 39% of all the specimens collected in the ICU. The most common MDR organisms isolated in this unit were A. baumannii, and K. pneumoniae (Author).

  2. Ward nurses' experiences of the discharge process between intensive care unit and general ward.

    Science.gov (United States)

    Kauppi, Wivica; Proos, Matilda; Olausson, Sepideh

    2018-05-01

    Intensive care unit (ICU) discharges are challenging practices that carry risks for patients. Despite the existing body of knowledge, there are still difficulties in clinical practice concerning unplanned ICU discharges, specifically where there is no step-down unit. The aim of this study was to explore general ward nurses' experiences of caring for patients being discharged from an ICU. Data were collected from focus groups and in-depth interviews with a total of 16 nurses from three different hospitals in Sweden. An inductive qualitative design was chosen. The analysis revealed three themes that reflect the challenges in nursing former ICU patients: a vulnerable patient, nurses' powerlessness and organizational structure. The nurses described the challenge of nursing a fragile patient based on several aspects. They expressed feeling unrealistic demands when caring for a fragile former ICU patient. The demands were related to their own profession and knowledge regarding how to care for this group of patients. The organizational structure had an impact on how the nurses' caring practice could be realized. This evoked ethical concerns that the nurses had to cope with as the organization's care guidelines did not always favour the patients. The structure of the organization and its leadership appear to have a significant impact on the nurses' ability to offer patients the care they need. This study sheds light on the need for extended outreach services and intermediate care in order to meet the needs of patients after the intensive care period. © 2018 British Association of Critical Care Nurses.

  3. Water use for electricity in the United States: an analysis of reported and calculated water use information for 2008

    International Nuclear Information System (INIS)

    Averyt, K; Meldrum, J; Macknick, J; Newmark, R; Rogers, J; Madden, N; Fisher, J

    2013-01-01

    Water use by the electricity sector represents a significant portion of the United States water budget (41% of total freshwater withdrawals; 3% consumed). Sustainable management of water resources necessitates an accurate accounting of all water demands, including water use for generation of electricity. Since 1985, the Department of Energy (DOE) Energy Information Administration (EIA) has collected self-reported data on water consumption and withdrawals from individual power generators. These data represent the only annual collection of water consumption and withdrawals by the electricity sector. Here, we compile publically available information into a comprehensive database and then calculate water withdrawals and consumptive use for power plants in the US. In effect, we evaluate the quality of water use data reported by EIA for the year 2008. Significant differences between reported and calculated water data are evident, yet no consistent reason for the discrepancies emerges. (letter)

  4. Method for controlling a nuclear fueled electric power generating unit and interfacing the same with a load dispatching system

    International Nuclear Information System (INIS)

    Mueller, N.P.; Meyer, C.E.

    1984-01-01

    A pressurized water reactor (PWR) nuclear fueled, electric power generating unit is controlled through the use of on-line calculations of the rapid, step and ramp, power change capabilities of the unit made from measured values of power level, axial offset, coolant temperature and rod position taking into account operator generated, safety and control, and balance of plant limits. The power change capabilities so generated may be fed to an automatic dispatch system which provides closed loop control of a power grid system. (author)

  5. Deposition and retention of plutonium in the United States general population

    International Nuclear Information System (INIS)

    McInroy, J.F.; Boyd, H.A.; Eutsler, B.C.

    1979-01-01

    Since 1959, a Los Alamos National Laboratory study has analyzed over 5000 tissues from 1100 individuals of the nonoccupationally exposed general population for fallout plutonium. These data have been useful in determining the tissue distributions and the annual baseline levels of environmental plutonium in the United States population. The effects of age, sex, date of death, cause of death and geographic location of resididence on the observed plutonium deposition have been evaluated. Because of the difference in biological turnover times of plutonium in the various organs of the body and the changing concentrations of plutonium in the atmosphere, the plutonium concentration ratios between tissues have changed as a function of time. However, our data indicate that over the past 10 years, the highest concentrations in the general population are found in the tracheobronchial lymph nodes and the liver and the lowest concentrations are in the spleen, gonads and kidney. The median body burdens of plutonium in the US population are estimated to have reached 12 pCi during the 1960's and have declined to about 2 pCi in 1977. Large errors in estimated skeletal burdens of plutonium may exist because of small specimen sample sizes and a lack of knowledge concerning the relative distribution of plutonium among the various bones of the human body

  6. Twenty years of electroconvulsive therapy in a psychiatric unit at a university general hospital

    Directory of Open Access Journals (Sweden)

    Amilton dos Santos Jr.

    2013-01-01

    Full Text Available Objective: To describe the sociodemographic and clinical profile of patients who underwent electroconvulsive therapy (ECT at a university general hospital. Method: In this retrospective study, records from all patients undergoing ECT between January 1988 and January 2008 at the psychiatric unit of the general hospital of Universidade Estadual de Campinas (UNICAMP were reviewed. Telephone contact was made with patients/relatives to collect follow-up data. Results: A total of 200 charts were reviewed. The majority of patients were women, with a mean age of 39 years, and history of psychiatric hospitalization. The main indications for ECT were depression and catatonia. Complications were observed in less than half of the cases, and most were temporary and not severe. There was a good psychiatric outcome for 89.7% of the patients, especially for catatonic patients (100%, p = 0.02. Thirty-four percent of the cases were later contacted by telephone calls, at a mean of 8.5 years between the procedure and the contact. Among these, three (1.5% reported persistent memory disorders and 73% considered ECT a good treatment. Conclusion: ECT has been performed according to international guidelines. In the vast majority of cases, undesirable effects were temporary and not severe. Response to ECT was positive in most cases, particularly in catatonic patients.

  7. A Revenue Equivalence Result in a Duopolistic Electricity Market where one of the suppliers has two production units

    Directory of Open Access Journals (Sweden)

    Estrella Alonso

    2012-04-01

    Full Text Available In this paper we will model the electricity market auction as a two-person game with incomplete information under the assumption that bid-ders are asymmetric in units production, risk neutral and with unknownvalues.We characterize the strictly monotone bayesian Nash equilibrium andwe rank a family of auction models which contains the classic models Uniform, Discriminatory and Vickrey auction models.

  8. Electricity

    Indian Academy of Sciences (India)

    Michael Faraday of England and Joseph Henry of the United. States are the .... frequency to be generated is f Hz, the number of poles required .... it would seem there is a very good reason to choose high frequency power generation. (In fact.

  9. The effects of electric power industry restructuring on the safety of nuclear power plants in the United States

    Science.gov (United States)

    Butler, Thomas S.

    Throughout the United States the electric utility industry is restructuring in response to federal legislation mandating deregulation. The electric utility industry has embarked upon an extraordinary experiment by restructuring in response to deregulation that has been advocated on the premise of improving economic efficiency by encouraging competition in as many sectors of the industry as possible. However, unlike the telephone, trucking, and airline industries, the potential effects of electric deregulation reach far beyond simple energy economics. This dissertation presents the potential safety risks involved with the deregulation of the electric power industry in the United States and abroad. The pressures of a competitive environment on utilities with nuclear power plants in their portfolio to lower operation and maintenance costs could squeeze them to resort to some risky cost-cutting measures. These include deferring maintenance, reducing training, downsizing staff, excessive reductions in refueling down time, and increasing the use of on-line maintenance. The results of this study indicate statistically significant differences at the .01 level between the safety of pressurized water reactor nuclear power plants and boiling water reactor nuclear power plants. Boiling water reactors exhibited significantly more problems than did pressurized water reactors.

  10. 75 FR 26794 - New United Motor Manufacturing, Inc., Formerly a Joint Venture of General Motors Corporation and...

    Science.gov (United States)

    2010-05-12

    ... Manufacturing, Inc., Formerly a Joint Venture of General Motors Corporation and Toyota Motor Corporation... United Motor Manufacturing, Inc., formerly a joint venture of General Motors Corporation and Toyota Motor... reviewed the certification for workers of the subject firm. The workers assemble the Toyota Corolla and the...

  11. Demands on project management of comprehensive modernization projects in the electrical systems area. Example of modernization of electrical systems of Kozloduy NPP Unit 5 and 6

    International Nuclear Information System (INIS)

    Stinshoff, Helmut; Weber, Patrick

    2006-01-01

    In nuclear power plants, station supply with electric energy must be guaranteed any time. This applies in particular also during the implementation of complex electrical systems modernization projects. Highest demands on the project management, extensive experience and system knowledge are required. In the frame of the Modernization Program for the nuclear power plant Kozloduy unit 5 and 6 in Bulgaria Framatome ANP has approved its ability to implement a large scope of modernization measures during the refueling outages of the years 2003 to 2005. The Contract of the Modernization Program for the European Consortium Kozloduy (Framatome ANP, Atomenergoexport) was signed in July 1999 and became effective in June 2001. The project will be finished by May 2006, with the approval of the Updated Final Safety Analysis Report. The scope of hardware work has been implemented within 6 plant outages during the years 2002 to 2005. The focus of the Modernization Program is mainly oriented to nuclear safety aspects, with the aim of upgrading of the Units to a high safety level in compliance with international practice. A further section of the project is dedicated to upgrading of operational equipment. Framatome ANP personnel have shown that besides the technical challenges which had to be faced, also the intercultural and language barriers were successfully overcome. The good teamwork between the partners of the Consortium ECK, its Bulgarian subcontractors and with Kozloduy plant personnel has been an important success factor. (authors)

  12. The Agency's Annual Report to the General Assembly of the United Nations for the Year 1969-70. Explanatory Note

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1970-11-13

    By Resolution GC(XIV)/RES/268 the General Conference requested the Board of Governors to arrange for the preparation of a supplement to the Board's annual report to the General Conference for 1969-70 which, together with that report, constitutes the Agency's report to the General Assembly of the United Nations for that year. The present document contains the supplement, which deals briefly with some developments in the Agency's work during the period 1 July to 1 October 1970.

  13. The Agency's Annual Report to the General Assembly of the United Nations for the Year 1968-69. Explanatory Note

    International Nuclear Information System (INIS)

    1969-01-01

    By Resolution GC(XIII)/RES/251 the General Conference requested the Board of Governors to arrange for the preparation of a supplement to the Board's annual report to the General Conference for 1968-69 which, together with that report, shall constitute the Agency's report to the General Assembly of the United Nations for that year. The present document contains the supplement, which deals briefly with some developments in the Agency's work during the period 1 July to 1 October 1969.

  14. The Agency's Annual Report to the General Assembly of the United Nations for the Year 1969-70. Explanatory Note

    International Nuclear Information System (INIS)

    1970-01-01

    By Resolution GC(XIV)/RES/268 the General Conference requested the Board of Governors to arrange for the preparation of a supplement to the Board's annual report to the General Conference for 1969-70 which, together with that report, constitutes the Agency's report to the General Assembly of the United Nations for that year. The present document contains the supplement, which deals briefly with some developments in the Agency's work during the period 1 July to 1 October 1970.

  15. Optimal Sizing and Sitting of Smart Microgrid Units under Pool Electricity Market

    DEFF Research Database (Denmark)

    Hakimi, Seyed Mehdi; Hajizadeh, Amin

    2017-01-01

    , reliability cost, power loss cost and selling and buying electricity cost. The new idea of this paper is the investigation of pool electricity market aspects in optimization of smart microgrid. On the other hand, cost minimization of smart microgrid is related to their bidding strategies. Therefore two...... different optimization tools are considered. First, a game-theoretical (GT) model has been used for bidding strategy of smart microgrid as a price-maker, in a long-term electricity market. Secondly, a particle swarm optimization (PSO) algorithm is employed to obtain the best cost value of smart microgrids...... construction. This study was performed for the Ekbatan residential complex in Tehran, Iran. It has three smart microgrids consist of renewable energy resources. They participate in a long-term electricity market as a price maker. The results show that the proposed method is more effective and has lower cost...

  16. Electrical engineering unit for the reactive power control of the load bus at the voltage instability

    Science.gov (United States)

    Kotenev, A. V.; Kotenev, V. I.; Kochetkov, V. V.; Elkin, D. A.

    2018-01-01

    For the purpose of reactive power control error reduction and decrease of the voltage sags in the electric power system caused by the asynchronous motors started the mathematical model of the load bus was developed. The model was built up of the sub-models of the following elements: a transformer, a transmission line, a synchronous and an asynchronous loads and a capacitor bank load, and represents the automatic reactive power control system taking into account electromagnetic processes of the asynchronous motors started and reactive power changing of the electric power system elements caused by the voltage fluctuation. The active power/time and reactive power/time characteristics based on the recommended procedure of the equivalent electric circuit parameters calculation were obtained. The derived automatic reactive power control system was shown to eliminate the voltage sags in the electric power system caused by the asynchronous motors started.

  17. Business model innovation in electricity supply markets: The role of complex value in the United Kingdom

    International Nuclear Information System (INIS)

    Hall, Stephen; Roelich, Katy

    2016-01-01

    This research investigates the new opportunities that business model innovations are creating in electricity supply markets at the sub-national scale. These local supply business models can offer significant benefits to the electricity system, but also generate economic, social, and environmental values that are not well accounted for in current policy or regulation. This paper uses the UK electricity supply market to investigate new business models which rely on more complex value propositions than the incumbent utility model. Nine archetypal local supply business models are identified and their value propositions, value capture methods, and barriers to market entry are analysed. This analysis defines 'complex value' as a key concept in understanding business model innovation in the energy sector. The process of complex value identification poses a challenge to energy researchers, commercial firms and policymakers in liberalised markets; to investigate the opportunities for system efficiency and diverse outcomes that new supplier business models can offer to the electricity system. - Highlights: •Business models of energy supply markets shape energy transitions. •The British system misses four opportunities of local electricity supply. •Nine new business model archetypes of local supply are analysed. •New electricity business models have complex value propositions. •A process for policy response to business model innovation is presented.

  18. Is there a water–energy nexus in electricity generation? Long-term scenarios for the western United States

    International Nuclear Information System (INIS)

    Ackerman, Frank; Fisher, Jeremy

    2013-01-01

    Water is required for energy supply, and energy is required for water supply, creating problems as demand for both resources grows. We analyze this “water–energy nexus” as it affects long-run electricity planning in the western United States. We develop four scenarios assuming: no new constraints; limits on carbon emissions; limits on water use; and combined carbon and water limits. We evaluate these scenarios through 2100 under a range of carbon and water prices. The carbon-reducing scenarios become cost-effective at carbon prices of about $50–$70 per ton of CO 2 , moderately high but plausible within the century. In contrast, the water-conserving scenarios are not cost-effective until water prices reach thousands of dollars per acre-foot, well beyond foreseeable levels. This is due in part to the modest available water savings: our most and least water-intensive scenarios differ by less than 1% of the region's water consumption. Under our assumptions, Western electricity generation could be reshaped by the cost of carbon emissions, but not by the cost of water, over the course of this century. Both climate change and water scarcity are of critical importance, but only in the former is electricity generation central to the problem and its solutions. - Highlights: • We model long-run electricity supply and demand for the western United States. • We evaluate the costs of carbon-reducing and water-conserving scenarios. • Carbon-reducing scenarios become cost-effective at carbon prices of $50–70 per ton CO 2 . • Water-conserving scenarios are only cost-effective above $4000/acre-foot of water. • Electricity planning is central to climate policy, but much less so to water planning

  19. Safety Evaluation Report related to the operation of Comanche Peak Steam Electric Station, Unit 2 (Docket No. 50-446)

    International Nuclear Information System (INIS)

    1992-09-01

    This document supplement 25 to the Safety Evaluation Report related to the operation of the Comanche Peak Steam Electric Station (CPSES), Unit 2 (NUREG-0797), has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission (NRC). The facility is located in Somervell County, Texas, approximately 40 miles southwest of Fort Worth, Texas. This supplement reports the status of certain issues that had not been resolved when the Safety Evaluation Report and Supplements 1, 2, 3, 4, 6, 12, 21, 22, 23, and 24 to that report were published. This supplement deals primarily with Unit 2 issues; however, it also references evaluations for several Unit 1 licensing items resolved since Supplement 24 was issued

  20. Safety Evaluation Report related to the operation of Comanche Peak Steam Electric Station, Unit 2 (Docket No. 50-446)

    International Nuclear Information System (INIS)

    1993-02-01

    Supplement 26 to the Safety Evaluation Report related to the operation of the Comanche Peak Steam Electric Station (CPSES), Unit 2, has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission (NRC). The facility is located in Somervell County, Texas, approximately 40 miles southwest of Fort Worth, Texas. This supplement reports the status of certain issues that had not been resolved when the Safety Evaluation Report and Supplements 1, 2, 3, 4, 6, 12, 21, 22, 23, 24, and 25 to that report were published. This supplement deals primarily with Unit 2 issues; however, it also references evaluations for several licensing issues that relate to Unit 1, which have been resolved since Supplement 25 was issued

  1. Estimating State-Specific Contributions to PM2.5- and O3-Related Health Burden from Residential Combustion and Electricity Generating Unit Emissions in the United States.

    Science.gov (United States)

    Penn, Stefani L; Arunachalam, Saravanan; Woody, Matthew; Heiger-Bernays, Wendy; Tripodis, Yorghos; Levy, Jonathan I

    2017-03-01

    Residential combustion (RC) and electricity generating unit (EGU) emissions adversely impact air quality and human health by increasing ambient concentrations of fine particulate matter (PM 2.5 ) and ozone (O 3 ). Studies to date have not isolated contributing emissions by state of origin (source-state), which is necessary for policy makers to determine efficient strategies to decrease health impacts. In this study, we aimed to estimate health impacts (premature mortalities) attributable to PM 2.5 and O 3 from RC and EGU emissions by precursor species, source sector, and source-state in the continental United States for 2005. We used the Community Multiscale Air Quality model employing the decoupled direct method to quantify changes in air quality and epidemiological evidence to determine concentration-response functions to calculate associated health impacts. We estimated 21,000 premature mortalities per year from EGU emissions, driven by sulfur dioxide emissions forming PM 2.5 . More than half of EGU health impacts are attributable to emissions from eight states with significant coal combustion and large downwind populations. We estimate 10,000 premature mortalities per year from RC emissions, driven by primary PM 2.5 emissions. States with large populations and significant residential wood combustion dominate RC health impacts. Annual mortality risk per thousand tons of precursor emissions (health damage functions) varied significantly across source-states for both source sectors and all precursor pollutants. Our findings reinforce the importance of pollutant-specific, location-specific, and source-specific models of health impacts in design of health-risk minimizing emissions control policies. Citation: Penn SL, Arunachalam S, Woody M, Heiger-Bernays W, Tripodis Y, Levy JI. 2017. Estimating state-specific contributions to PM 2.5 - and O 3 -related health burden from residential combustion and electricity generating unit emissions in the United States. Environ

  2. Straight and chopped dc performance data for a Prestolite MTC-4001 motor and a general electric EV-1 controller

    Science.gov (United States)

    Edie, P. C.

    1981-01-01

    Performance data on the Prestolite MTC-4001 series wound dc motor and General Electric EV-1 Chopper Controller is supplied for the electric vehicle manufacturer. Data are provided for both straight and chopped dc input to the motor, at 2 motor temperature levels. Testing was done at 6 voltage increments to the motor, and 2 voltage increments to the controller. Data results are presented in both tabular and graphical forms. Tabular information includes motor voltage and current input data, motor speed and torque output data, power data and temperature data. Graphical information includes torque-speed, motor power output-speed, torque-current, and efficiency-speed plots under the various operating conditions. The data resulting from this testing show the speed-torque plots to have the most variance with operating temperature. The maximum motor efficiency is between 76% and 82%, regardless of temperature or mode of operation.

  3. Generalized monitor unit calculation for the Varian enhanced dynamic wedge field

    International Nuclear Information System (INIS)

    Liu Chihray; Kim, Siyong; Kahler, Darren L.; Palta, Jatinder R.

    2003-01-01

    The generalized monitor unit (MU) calculation equation for the Varian enhanced dynamic wedge (EDW) is derived. The assumption of this MU calculation method is that the wedge factor of the EDW at the center of the field is a function of field size, the position of the center of the field in the wedge direction, and the final position of the moving jaw. The wedge factors at the center of the field in both symmetric and asymmetric fields are examined. The difference between calculated and measured wedge factors is within 1.0%. The method developed here is easy to implement. The only datum required in addition to the standard set of conventional physical wedge implementation data is the off-axis output factor for the open field in the reference condition. The off-center point calculation is also examined. For the off-center point calculation, the dose profile in the wedge direction for the largest EDW field is used to obtain the relative off-center ratio in any smaller wedge field. The accuracy of the off-center point calculation decreases when the point of calculation is too close to the field edge

  4. H-index and academic rank in general surgery and surgical specialties in the United States.

    Science.gov (United States)

    Ashfaq, Awais; Kalagara, Roshini; Wasif, Nabil

    2018-09-01

    H-index serves as an alternative to measure academic achievement. Our objective is to study the h-index as a measure of academic attainment in general surgery and surgical specialties. A database of all surgical programs in the United States was created. Publish or Perish software was used to determine surgeons h-index. A total of 134 hospitals and 3712 surgeons (79% male) were included. Overall, mean h-index was 14.9 ± 14.8. H-index increased linearly with academic rank: 6.8 ± 6.4 for assistant professors (n = 1557, 41.9%), 12.9 ± 9.3 for associate professors (n = 891, 24%), and 27.9 ± 17.4 for professors (n = 1170, 31.5%); P h-indices (18.7 ± 16.7 and 18.4 ± 17.6, respectively). Surgeons with additional postgraduate degrees, university affiliations and male had higher mean h-indices; P h-index and the number of publications (R2 = 0.817) and citations (R2 = 0.768). The h-index of academic surgeons correlates with academic rank and serves a potential tool to measure academic productivity. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Reliability analysis of a phaser measurement unit using a generalized fuzzy lambda-tau(GFLT) technique.

    Science.gov (United States)

    Komal

    2018-05-01

    Nowadays power consumption is increasing day-by-day. To fulfill failure free power requirement, planning and implementation of an effective and reliable power management system is essential. Phasor measurement unit(PMU) is one of the key device in wide area measurement and control systems. The reliable performance of PMU assures failure free power supply for any power system. So, the purpose of the present study is to analyse the reliability of a PMU used for controllability and observability of power systems utilizing available uncertain data. In this paper, a generalized fuzzy lambda-tau (GFLT) technique has been proposed for this purpose. In GFLT, system components' uncertain failure and repair rates are fuzzified using fuzzy numbers having different shapes such as triangular, normal, cauchy, sharp gamma and trapezoidal. To select a suitable fuzzy number for quantifying data uncertainty, system experts' opinion have been considered. The GFLT technique applies fault tree, lambda-tau method, fuzzified data using different membership functions, alpha-cut based fuzzy arithmetic operations to compute some important reliability indices. Furthermore, in this study ranking of critical components of the system using RAM-Index and sensitivity analysis have also been performed. The developed technique may be helpful to improve system performance significantly and can be applied to analyse fuzzy reliability of other engineering systems. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  6. Portland General Electric Company report on the operating and startup experience with control and instrumentation and electrical systems at the Trojan Nuclear Plant

    International Nuclear Information System (INIS)

    Zimmerman, G.A.

    1977-01-01

    The Trojan Nuclear Plant is an 1178 MWe nuclear plant located on the Columbia River 40 miles northwest of Portland, Oregon. The Nuclear Stream Supply System vendor is Westinghouse with a General Electric turbine generator. The reactor is rated and licensed for 3423 MWt (1178 MWe) and the turbine generator is designed for 3570 MWt(1219 MWe). The startup phase testing of Trojan commenced on November 21, 1975, upon receipt of our NRC Operating License. The startup testing program was completed on May 22, 1976, following 100 hours of full-power operation, at which time a scheduled summer maintenance outage began. Some of the highlights and milestones of the startup testing program are described

  7. Electricity consumption and energy savings potential of video game consoles in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Hittinger, E.; Mullins, K.A.; Azevedo, I.L. [Department of Engineering and Public Policy, Carnegie Mellon University, Pittsburgh, PA 15213 (United States)

    2012-11-15

    Total energy consumption of video game consoles has grown rapidly in the past few decades due to rapid increases in market penetration, power consumption of the devices, and increasing usage driven by new capabilities. Unfortunately, studies investigating the energy impacts of these devices have been limited and potential responses, such as ENERGY STAR requirements, have been difficult to define and implement. We estimate that the total electricity consumption of video game consoles in the US was around 11 TWh in 2007 and 16 TWh in 2010 (approximately 1 % of US residential electricity consumption), an increase of almost 50 % in 3 years. However, any estimate of total game console energy consumption is highly uncertain, and we have determined that the key uncertainty is the unknown consumer behavior with regards to powering down the system after use. Even under this uncertainty, we demonstrate that the most effective energy-saving modification is incorporation of a default auto power down feature, which could reduce electricity consumption of game consoles by 75 % (10 TWh reduction of electricity in 2010), saving consumers over USD 1 billion annually in electricity bills. We conclude that using an auto power down feature for game consoles is at least as effective for reducing energy consumption as implementing a strict set of energy efficiency improvements for the devices, is much easier to implement given the nature of the video game console industry, and could be applied retroactively to currently deployed consoles through firmware updates.

  8. Qualification of electrical equipment. A United States nuclear system supplier perspective

    International Nuclear Information System (INIS)

    Jordan, W.G.

    1978-01-01

    At Westinghouse Pressurized Water Reactor Systems Division (PWR-SD) qualification. of safety related electrical equipment can be segregated into three distinct generations: (1) the initial seismic and environmental qualification programs for electrical equipment (1969-1972); (2) the supplemental sismic and environmental qualification programs (1975-1977); and (3) the seismic and environmental qualification programs to meet IEEE-323-1974, IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations''(1975). The latter two programs (in a licensing framework), as they are most current, with emphasis on electrical equipment (e.g. transmitters, rack mounted equipment) as opposed to electro-mechanical equipment (valve operators, pump motors) are reviewed. (author)

  9. Future trends in electrical energy generation economics in the United States

    Science.gov (United States)

    Schmitt, R. W.; Fox, G. R.; Shah, R. P.; Stewart, P. J.; Vermilyea, D. A.

    1977-01-01

    Developments related to the economics of coal-fired systems in the U.S. are mainly considered. The historical background of the U.S. electric generation industry is examined and the U.S. electrical generation characteristics in the year 1975 are considered. It is pointed out that coal-fired power plants are presently the largest source of electrical energy generation in the U.S. Questions concerning the availability and quality of coal are investigated. Currently there are plans for converting some 50 large oil and gas-fired generating plants to coal, and it is expected that coal will be the fuel used in almost all fossil-fired base load additions to generating capacity. Aspects of advanced energy conversion from coal are discussed, taking into account the performance and economic potential of the energy conversion systems.

  10. Motor unit firing intervals and other parameters of electrical activity in normal and pathological muscle

    DEFF Research Database (Denmark)

    Fuglsang-Frederiksen, Anders; Smith, T; Høgenhaven, H

    1987-01-01

    The analysis of the firing intervals of motor units has been suggested as a diagnostic tool in patients with neuromuscular disorders. Part of the increase in number of turns seen in patients with myopathy could be secondary to the decrease in motor unit firing intervals at threshold force...

  11. Operational experience in the non-destructive assay of fissile material in General Electric's nuclear fuel fabrication facility

    International Nuclear Information System (INIS)

    Stewart, J.P.

    1976-01-01

    Operational experience in the non-destructive assay of fissile material in a variety of forms and containers and incorporation of the assay devices into the accountability measurement system for General Electric's Wilmington Fuel Fabrication Facility measurement control programme is detailed. Description of the purpose and related operational requirements of each non-destructive assay system is also included. In addition, the accountability data acquisition and processing system is described in relation to its interaction with the various non-destructive assay devices and scales used for accountability purposes within the facility. (author)

  12. Combined Solar Charging Stations and Energy Storage Units Allocation for Electric Vehicles by Considering Uncertainties

    DEFF Research Database (Denmark)

    Yousefi Khanghah, Babak; Anvari-Moghaddam, Amjad; Guerrero, Josep M.

    2017-01-01

    Electric vehicles (EVs) are becoming a key feature of smart grids. EVs will be embedded in the smart grids as a mobile load-storage with probabilistic behavior. In order to manage EVs as flexible loads, charging stations (CSs) have essential roles. In this paper, a new method for optimal sitting...... are considered based on time-of-use (TOU) demand response programs (DRPs). In order to solve the optimization problem considering uncertainty of load growth, electricity price, initial state of charge of batteries and solar power generation, genetic algorithm method using Monte-Carlo simulation is used...

  13. Annual Report to the General Assembly of the United Nations for the year 1964-65. Explanatory Note

    International Nuclear Information System (INIS)

    1965-01-01

    By Resolution GC(IX)/RES/l87 the General Conference decided that the Agency's Annual Report to the General Assembly of the United Nations for 1964-65 would consist of the annual report of the Board of Governors to the General Conference for 1964-65, together with a supplement. The annual report has been issued as document GC(IX)/299. The present document contains the supplement which deals with developments in the Agency's work during the period 1 July to 1 October 1965, including action taken by the General Conference at its ninth regular session which took place in Tokyo from 21 to 28 September 1965

  14. Annual Report to the General Assembly of the United Nations for the Year 1959-60. Explanatory Note

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1960-10-21

    By resolution GC(IV)/RES/62 the General Conference decided that the Agency's annual report to the General Assembly of the United Nations for 1959-60 would consist of the annual report of the Board of Governors to the General Conference for 1959-60, together with a supplement. The annual report of the Board has been issued as document GC(IV)/ 114. The present document contains the supplement which deals with developments in the Agency's work during the period 1 July to 30 September 1960, including action taken by the General Conference at its fourth regular session.

  15. Annual Report to the General Assembly of the United Nations for the year 1964-65. Explanatory Note

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1965-10-29

    By Resolution GC(IX)/RES/l87 the General Conference decided that the Agency's Annual Report to the General Assembly of the United Nations for 1964-65 would consist of the annual report of the Board of Governors to the General Conference for 1964-65, together with a supplement. The annual report has been issued as document GC(IX)/299. The present document contains the supplement which deals with developments in the Agency's work during the period 1 July to 1 October 1965, including action taken by the General Conference at its ninth regular session which took place in Tokyo from 21 to 28 September 1965.

  16. Annual Report to the General Assembly of the United Nations for the Year 1960-61. Explanatory Note

    International Nuclear Information System (INIS)

    1961-01-01

    By resolution GC(V)/RES/89 the General Conference decided that the Agency's annual report to the General Assembly of the United Nations for 1960-61 would consist of the annual report of the Board of Governors to the General Conference for 1960-61, together with a supplement. The annual report of the Board has been issued as document GC(V)/154. The present document contains the supplement which deals with developments in the Agency's work during the period 1 July to 6 October 1961, including action taken by the General Conference at its fifth regular session

  17. Annual Report to the General Assembly of the United Nations for the Year 1961-62. Explanatory Note

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1962-10-12

    By Resolution GC(VI)/RES/114 the General Conference decided that the Agency's annual report to the General Assembly of the United Nations for 1961-62 would consist of the annual report of the Board of Governors to the General Conference for 1961-62, together with a supplement. The annual report of the Board has been issued as document GC(VI)/195. The present document contains the supplement which deals with developments in the Agency's work during the period 1 July to 1 October 1962, including action taken by the General Conference at its sixth regular session.

  18. Annual Report to the General Assembly of the United Nations for the Year 1960-61. Explanatory Note

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1961-10-26

    By resolution GC(V)/RES/89 the General Conference decided that the Agency's annual report to the General Assembly of the United Nations for 1960-61 would consist of the annual report of the Board of Governors to the General Conference for 1960-61, together with a supplement. The annual report of the Board has been issued as document GC(V)/154. The present document contains the supplement which deals with developments in the Agency's work during the period 1 July to 6 October 1961, including action taken by the General Conference at its fifth regular session.

  19. Annual Report to the General Assembly of the United Nations for the Year 1959-60. Explanatory Note

    International Nuclear Information System (INIS)

    1960-01-01

    By resolution GC(IV)/RES/62 the General Conference decided that the Agency's annual report to the General Assembly of the United Nations for 1959-60 would consist of the annual report of the Board of Governors to the General Conference for 1959-60, together with a supplement. The annual report of the Board has been issued as document GC(IV)/ 114. The present document contains the supplement which deals with developments in the Agency's work during the period 1 July to 30 September 1960, including action taken by the General Conference at its fourth regular session

  20. Annual Report to the General Assembly of the United Nations for the Year 1961-62. Explanatory Note

    International Nuclear Information System (INIS)

    1962-01-01

    By Resolution GC(VI)/RES/114 the General Conference decided that the Agency's annual report to the General Assembly of the United Nations for 1961-62 would consist of the annual report of the Board of Governors to the General Conference for 1961-62, together with a supplement. The annual report of the Board has been issued as document GC(VI)/195. The present document contains the supplement which deals with developments in the Agency's work during the period 1 July to 1 October 1962, including action taken by the General Conference at its sixth regular session

  1. A critique of the US Surgeon General?s conclusions regarding e-cigarette use among youth and young adults in the United States of America

    OpenAIRE

    Polosa, Riccardo; Russell, Christopher; Nitzkin, Joel; Farsalinos, Konstantinos E.

    2017-01-01

    Background In December 2016, the Surgeon General published a report that concluded e-cigarette use among youth and young adults is becoming a major public health concern in the United States of America. Methods Re-analysis of key data sources on nicotine toxicity and prevalence of youth use of e-cigarettes cited in the Surgeon General report as the basis for its conclusions. Results Multiple years of nationally representative surveys indicate the majority of e-cigarette use among US youth is ...

  2. Generalized Energy Flow Analysis Considering Electricity Gas and Heat Subsystems in Local-Area Energy Systems Integration

    Directory of Open Access Journals (Sweden)

    Jiaqi Shi

    2017-04-01

    Full Text Available To alleviate environmental pollution and improve the efficient use of energy, energy systems integration (ESI—covering electric power systems, heat systems and natural gas systems—has become an important trend in energy utilization. The traditional power flow calculation method, with the object as the power system, will prove difficult in meeting the requirements of the coupled energy flow analysis. This paper proposes a generalized energy flow (GEF analysis method which is suitable for an ESI containing electricity, heat and gas subsystems. First, the models of electricity, heat, and natural gas networks in the ESI are established. In view of the complexity of the conventional method to solve the gas network including the compressor, an improved practical equivalent method was adopted based on different control modes. On this basis, a hybrid method combining homotopy and the Newton-Raphson algorithm was executed to compute the nonlinear equations of GEF, and the Jacobi matrix reflecting the coupling relationship of multi-energy was derived considering the grid connected mode and island modes of the power system in the ESI. Finally, the validity of the proposed method in multi-energy flow calculation and the analysis of interacting characteristics was verified using practical cases.

  3. A control technique for integration of DG units to the electrical networks

    DEFF Research Database (Denmark)

    Pouresmaeil, Edris; Miguel-Espinar, Carlos; Massot-Campos, Miquel

    2013-01-01

    This paper deals with a multiobjective control technique for integration of distributed generation (DG) resources to the electrical power network. The proposed strategy provides compensation for active, reactive, and harmonic load current components during connection of DG link to the grid...

  4. Competition in the electricity supply industry. Experiences from Europe and the United States

    International Nuclear Information System (INIS)

    Olsen, O.J.

    1995-01-01

    Introducing competition in the electricity industry is a major social experiment. Historically, the industry has been heavily regulated, however, this is no longer the case. Production and sales are being opened for competition and separated from the network services, transmission and distribution. This book includes papers from a Nordic Conference held in September 1994 in Copenhagen. The conference was planned as a part of the Energy Research Programme under the Nordic Council of Ministers and the object was to discuss the Nordic experience of competition in the electricity industry in comparison with other Western countries. The U.K. was the first European country to introduce competition in its electricity industry. Norway came next and two other Nordic countries - Sweden and Finland - have decided to follow suit. The U.S. started earlier than the European countries opening for limited competition in power production. However, the background of the reforms and its approach in the U.S. is different from Europe and far less radical. The experience of two Central European countries - Germany and The Netherlands - is also included in this book. Both countries have many institutional similarities to the Nordic countries, but they are - together with Denmark - more hesitant about introducing competition in their electricity industries. (au)

  5. Utilizing General Purpose Graphics Processing Units to Improve Performance of Computer Modelling and Visualization

    Science.gov (United States)

    Monk, J.; Zhu, Y.; Koons, P. O.; Segee, B. E.

    2009-12-01

    With the introduction of the G8X series of cards by nVidia an architecture called CUDA was released, virtually all subsequent video cards have had CUDA support. With this new architecture nVidia provided extensions for C/C++ that create an Application Programming Interface (API) allowing code to be executed on the GPU. Since then the concept of GPGPU (general purpose graphics processing unit) has been growing, this is the concept that the GPU is very good a algebra and running things in parallel so we should take use of that power for other applications. This is highly appealing in the area of geodynamic modeling, as multiple parallel solutions of the same differential equations at different points in space leads to a large speedup in simulation speed. Another benefit of CUDA is a programmatic method of transferring large amounts of data between the computer's main memory and the dedicated GPU memory located on the video card. In addition to being able to compute and render on the video card, the CUDA framework allows for a large speedup in the situation, such as with a tiled display wall, where the rendered pixels are to be displayed in a different location than where they are rendered. A CUDA extension for VirtualGL was developed allowing for faster read back at high resolutions. This paper examines several aspects of rendering OpenGL graphics on large displays using VirtualGL and VNC. It demonstrates how performance can be significantly improved in rendering on a tiled monitor wall. We present a CUDA enhanced version of VirtualGL as well as the advantages to having multiple VNC servers. It will discuss restrictions caused by read back and blitting rates and how they are affected by different sizes of virtual displays being rendered.

  6. Unplanned intensive care unit admission after general anaesthesia in children: A single centre retrospective analysis.

    Science.gov (United States)

    Mitchell, John; Clément de Clety, Stephan; Collard, Edith; De Kock, Marc; Detaille, Thierry; Houtekie, Laurent; Jadin, Laurence; Bairy, Laurent; Veyckemans, Francis

    2016-06-01

    To determine the main causes for unplanned admission of children to the paediatric intensive care unit (PICU) following anaesthesia in our centre. To compare the results with previous publications and propose a data sheet for the prospective collection of such information. Inclusion criteria were any patient under 16 years who had an unplanned post-anaesthetic admission to the PICU from 1999 to 2010 in our university hospital. Age, ASA score, type of procedure, origin and causes of the incident(s) that prompted admission and time of the admission decision were recorded. Out of a total of 44,559 paediatric interventions performed under anaesthesia during the study period, 85 were followed with an unplanned admission to the PICU: 67% of patients were younger than 5 years old. Their ASA status distribution from I to IV was 13, 47, 39 and 1%, respectively. The cause of admission was anaesthetic, surgical or mixed in 50, 37 and 13% of cases, respectively. The main causes of anaesthesia-related admission were respiratory or airway management problems (44%) and cardiac catheterisation complications (29%). In 62%, the admission decision was taken in the operating room. Unplanned admission to the PICU after general anaesthesia is a rare event. In our series, most cases were less than 5 years old and were associated with at least one comorbidity. The main cause of admission was respiratory distress and the main type of procedure associated with admission was cardiac catheterisation. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  7. Office of Inspector General report on audit of the Western Area Power Administration`s contract with Basin Electric Power Cooperative

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-25

    At the request of the Western Area Power Administration (Western), an audit of 17 areas was conducted with respect to possible overcharges on a power contract between Western and Basin Electric Power Cooperative (Basin), Contract No. DE-MP65-82WP-19001. The contract for Western`s purchase of electric power from Basin was entered into on April 15, 1982, and was in effect from January 1, 1986, through October 31, 1990. During this 58-month period, Basin billed Western approximately $197.6 million. Overall, it was found that Basin overcharged Western approximately $23.8 million. These overcharges occurred because Basin: (1) did not recognize or amortize as gain its overestimate of completion and correction costs for Antelope Valley Station (AVS) Unit 2; (2) did not amortize the gain on the sale/leaseback of AVS Unit 2 as an offset to lease costs; (3) billed Western prematurely for lease and interest costs; (4) overcharged for the cost of coal by including administrative and general expenses and profit, as well as incorrectly calculating discounts, royalty payments, and imputed interest costs; (5) made faulty calculations of amortization rates for deferred costs; (6) used a shorter depreciation period for AVS common facilities than it had used for other power plants; (7) retained tax benefit transfers; and (8) charged Western for interest and depreciation that had been paid by others. In addition to the $23.8 million in overcharges, interest accrued on the overcharges through December 31, 1996 was estimated to be approximately $22.1 million, resulting in a total of $45.9 million due Western.

  8. 78 FR 38411 - Vogtle Electric Generating Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria

    Science.gov (United States)

    2013-06-26

    ... Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) staff has determined that the inspections, tests...

  9. Safety Evaluation Report related to the operation of Waterford Steam Electric Station, Unit No. 3 (Docket No. 50-382)

    International Nuclear Information System (INIS)

    1985-03-01

    Supplement 10 to the Safety Evaluation Report for the application filed by Louisiana Power and Light Company for a license to operate the Waterford Steam Electric Station, Unit 3 (Docket No. 50-382), located in St. Charles Parish, Louisiana, has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. The purpose of this supplement is to update the Safety Evaluation Report by providing the staff's evaluation of information submitted by the licensee since the Safety Evaluation Report and its nine previous supplements were issued

  10. Determining the Residual Lifetime of Qualified Electrical and I and C Equipment in Units 5 and 6 of Kozloduy NPP

    International Nuclear Information System (INIS)

    Radoslavov, Biser

    2012-01-01

    The proposed paper clarifies the environmental qualification and residual lifetime of installed equipment and electrical cables in operating WWER 1000 type units 5 and 6 of Kozloduy NPP. The qualification approach is a combination of analyses and tests in consideration of some specific features of WWER equipment. As a result of the study, selected equipment is divided in 26 groups. Qualification groups include similar types of equipment with equal resistance to foreign impacts, analogous critical parts, and same methods of control and estimation of residual lifetime. Qualification protocols were made for each group. (author)

  11. ANALYSIS OF THE CONCEPT OF THE PRINCIPLES GENERALLY ACCEPTED ACCOUNTING OF UNITED STATES OF AMERICA (FASB RULES)

    OpenAIRE

    Vílchez Olivares, Percy Antonio

    2014-01-01

    The Framework for the preparation and presentation of financial statements is a statement that directs and informs the accounting principles generally accepted in the United States (U.S. GAAP), which in turn is valid in our country, on the application to determine the accounting principles generally accepted in Peru, in its supplementary nature as established by Resolution No. 013-98 Accounting Standards Council, an organ of the Public Accounts of the Nation. The Framework is the backbone of ...

  12. USING THE GENERAL ELECTRIC / MCKINSEY MATRIX IN THE PROCESS OF SELECTING THE CENTRAL AND EAST EUROPEAN MARKETS

    Directory of Open Access Journals (Sweden)

    Nicolae Răzvan Decuseară

    2013-01-01

    Full Text Available Due to limited resources a company cannot serve all potential markets in the world in a manner that all the clients to be satisfied and the business goals achieved, which is why the company should select the most appropriate markets. It can focus on a single product market serving many geographic areas, but may also decide to serve different product markets in a group of selected geographic areas. Due to the large number and diversity of markets that can choose, analyze of the market attractiveness and the selection the most interesting is a complex process. General Electric Matrix/McKinsey has two dimensions, market attractiveness and the competitive strength of the firm, and aims to analyze the strengths and weaknesses of the company in a variety of areas, allowing the company to identify the most attractive markets and to guide managers in allocating resources to these markets, improve the weaker competitive position of the company in emerging markets, or to draw firm unattractive markets. We can say that it is a very efficient tool for the company being used by international market specialists, on one hand to select foreign markets for the company, and on the other hand, to determine the strategy that the firm will be using to internationalize on those markets. At the end of this paper we present a part of a larger study in which we showed how General Electric Matrix/McKinsey it is used specifically in select foreign markets.

  13. Updated greenhouse gas and criteria air pollutant emission factors and their probability distribution functions for electricity generating units

    International Nuclear Information System (INIS)

    Cai, H.; Wang, M.; Elgowainy, A.; Han, J.

    2012-01-01

    Greenhouse gas (CO 2 , CH 4 and N 2 O, hereinafter GHG) and criteria air pollutant (CO, NO x , VOC, PM 10 , PM 2.5 and SO x , hereinafter CAP) emission factors for various types of power plants burning various fuels with different technologies are important upstream parameters for estimating life-cycle emissions associated with alternative vehicle/fuel systems in the transportation sector, especially electric vehicles. The emission factors are typically expressed in grams of GHG or CAP per kWh of electricity generated by a specific power generation technology. This document describes our approach for updating and expanding GHG and CAP emission factors in the GREET (Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation) model developed at Argonne National Laboratory (see Wang 1999 and the GREET website at http://greet.es.anl.gov/main) for various power generation technologies. These GHG and CAP emissions are used to estimate the impact of electricity use by stationary and transportation applications on their fuel-cycle emissions. The electricity generation mixes and the fuel shares attributable to various combustion technologies at the national, regional and state levels are also updated in this document. The energy conversion efficiencies of electric generating units (EGUs) by fuel type and combustion technology are calculated on the basis of the lower heating values of each fuel, to be consistent with the basis used in GREET for transportation fuels. On the basis of the updated GHG and CAP emission factors and energy efficiencies of EGUs, the probability distribution functions (PDFs), which are functions that describe the relative likelihood for the emission factors and energy efficiencies as random variables to take on a given value by the integral of their own probability distributions, are updated using best-fit statistical curves to characterize the uncertainties associated with GHG and CAP emissions in life-cycle modeling with GREET.

  14. Updated greenhouse gas and criteria air pollutant emission factors and their probability distribution functions for electricity generating units

    Energy Technology Data Exchange (ETDEWEB)

    Cai, H.; Wang, M.; Elgowainy, A.; Han, J. (Energy Systems)

    2012-07-06

    Greenhouse gas (CO{sub 2}, CH{sub 4} and N{sub 2}O, hereinafter GHG) and criteria air pollutant (CO, NO{sub x}, VOC, PM{sub 10}, PM{sub 2.5} and SO{sub x}, hereinafter CAP) emission factors for various types of power plants burning various fuels with different technologies are important upstream parameters for estimating life-cycle emissions associated with alternative vehicle/fuel systems in the transportation sector, especially electric vehicles. The emission factors are typically expressed in grams of GHG or CAP per kWh of electricity generated by a specific power generation technology. This document describes our approach for updating and expanding GHG and CAP emission factors in the GREET (Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation) model developed at Argonne National Laboratory (see Wang 1999 and the GREET website at http://greet.es.anl.gov/main) for various power generation technologies. These GHG and CAP emissions are used to estimate the impact of electricity use by stationary and transportation applications on their fuel-cycle emissions. The electricity generation mixes and the fuel shares attributable to various combustion technologies at the national, regional and state levels are also updated in this document. The energy conversion efficiencies of electric generating units (EGUs) by fuel type and combustion technology are calculated on the basis of the lower heating values of each fuel, to be consistent with the basis used in GREET for transportation fuels. On the basis of the updated GHG and CAP emission factors and energy efficiencies of EGUs, the probability distribution functions (PDFs), which are functions that describe the relative likelihood for the emission factors and energy efficiencies as random variables to take on a given value by the integral of their own probability distributions, are updated using best-fit statistical curves to characterize the uncertainties associated with GHG and CAP emissions in life

  15. General Electric Company analytical model for loss-of-coolant analysis in accordance with 10CFR50 appendix K. Volume II

    International Nuclear Information System (INIS)

    1976-01-01

    Documentation for the General Electric Evaluation Model is presented. Computer codes and numerical methods common to the codes are described. It is shown how GE BWR's conform to the Acceptance Criteria of 10CFR50.46

  16. Analysis of drought impacts on electricity production in the Western and Texas interconnections of the United States.

    Energy Technology Data Exchange (ETDEWEB)

    Harto, C. B.; Yan, Y. E.; Demissie, Y. K.; Elcock, D.; Tidwell, V. C.; Hallett, K.; Macknick, J.; Wigmosta, M. S.; Tesfa, T. K. (Environmental Science Division); (Sandia National Laboratory); (National Renewable Energy Laboratory); (Pacific Northwest National Laboratory)

    2012-02-09

    Electricity generation relies heavily on water resources and their availability. To examine the interdependence of energy and water in the electricity context, the impacts of a severe drought to assess the risk posed by drought to electricity generation within the western and Texas interconnections has been examined. The historical drought patterns in the western United States were analyzed, and the risk posed by drought to electricity generation within the region was evaluated. The results of this effort will be used to develop scenarios for medium- and long-term transmission modeling and planning efforts by the Western Electricity Coordination Council (WECC) and the Electric Reliability Council of Texas (ERCOT). The study was performed in response to a request developed by the Western Governors Association in conjunction with the transmission modeling teams at the participating interconnections. It is part of a U.S. Department of Energy-sponsored, national laboratory-led research effort to develop tools related to the interdependency of energy and water as part of a larger interconnection-wide transmission planning project funded under the American Recovery and Reinvestment Act. This study accomplished three main objectives. It provided a thorough literature review of recent studies of drought and the potential implications for electricity generation. It analyzed historical drought patterns in the western United States and used the results to develop three design drought scenarios. Finally, it quantified the risk to electricity generation for each of eight basins for each of the three drought scenarios and considered the implications for transmission planning. Literature on drought impacts on electricity generation describes a number of examples where hydroelectric generation capacity has been limited because of drought but only a few examples of impact on thermoelectric generation. In all documented cases, shortfalls of generation were met by purchasing power

  17. Impact of competitive electricity market on renewable generation technology choice and policies in the United States

    International Nuclear Information System (INIS)

    Sarkar, Ashok

    1999-01-01

    Market objectives based on private value judgments will conflict with social policy objectives toward environmental quality in an emerging restructured electricity industry. This might affect the choice of renewables in the future generation mix. The US electricity industry's long-term capacity planning and operations is simulated for alternative market paradigms to study this impact. The analysis indicates that the share of renewable energy generation sources would decrease and emissions would increase considerably in a more competitive industry, with greater impact occurring in a monopoly market. Alternative environmental policy options can overcome market failures and help achieve appropriate levels of renewable generation. An evaluation of these policies indicate their varying cost-effectiveness, with higher levels of intervention necessary if market power exists. (Author)

  18. Digital Grid: Transforming the Electric Power Grid into an Innovation Engine for the United States

    OpenAIRE

    Chakrabortty, Aranya; Huang, Alex

    2017-01-01

    The electric power grid is one of the largest and most complex infrastructures ever built by mankind. Modern civilization depends on it for industry production, human mobility, and comfortable living. However, many critical technologies such as the 60 Hz transformers were developed at the beginning of the 20th century and have changed very little since then.1 The traditional unidirectional power from the generation to the customer through the transmission-distribution grid has also changed no...

  19. Cost modelling of electricity-producing hot dry rock (HDR) geothermal systems in the United Kingdom

    International Nuclear Information System (INIS)

    Doherty, P.; Harrison, R.

    1995-01-01

    A detailed and comprehensive cost model for Hot Dry Rock (HDR) electricity producing systems has been developed in this study. The model takes account of the major aspects of the HDR system, parameterized in terms of the main physical and cost parameters of the resource and the utilization system. A doublet configuration is assumed, and the conceptual HDR system which is defined in the study is based upon the UK Department of Energy (DEn) HDR geothermal R and D programme. The model has been used to calculate the costs of HDR electricity for a UK defined base case which represents a consensus view of what might be achieved in Cornwall in the long term. At 14.2 p/kWh (1988 costs) this cost appears to be unacceptably high. A wide-ranging sensitivity study has also been carried out on the main resource, geometrical, and operational parameters of the HDR system centred around the UK base case. The sensitivity study shows the most important parameters to be thermal gradient and depth. The geometrical arrangement and the shape of the reservoir constitute major uncertainties in HDR systems. Their effect on temperature has a major influence on system performance, and therefore a range of theoretically possible geometries have been studied and the importance of geometrical effects on HDR electricity costs assessed. The most cost effective HDR arrangement in terms of optimized volumes and flow rates has been investigated for a world-wide range of thermal settings. The main conclusions from this study suggests that for HDR electricity to be economic, thermal gradients of 55 o C/km and above, well depths of 5 km or less, and production fluid temperatures of 210 o C and above are required. (UK)

  20. High gamma power in ECoG reflects cortical electrical stimulation effects on unit activity in layers V/VI

    Science.gov (United States)

    Yazdan-Shahmorad, Azadeh; Kipke, Daryl R.; Lehmkuhle, Mark J.

    2013-12-01

    Objective. Cortical electrical stimulation (CES) has been used extensively in experimental neuroscience to modulate neuronal or behavioral activity, which has led this technique to be considered in neurorehabilitation. Because the cortex and the surrounding anatomy have irregular geometries as well as inhomogeneous and anisotropic electrical properties, the mechanism by which CES has therapeutic effects is poorly understood. Therapeutic effects of CES can be improved by optimizing the stimulation parameters based on the effects of various stimulation parameters on target brain regions. Approach. In this study we have compared the effects of CES pulse polarity, frequency, and amplitude on unit activity recorded from rat primary motor cortex with the effects on the corresponding local field potentials (LFP), and electrocorticograms (ECoG). CES was applied at the surface of the cortex and the unit activity and LFPs were recorded using a penetrating electrode array, which was implanted below the stimulation site. ECoGs were recorded from the vicinity of the stimulation site. Main results. Time-frequency analysis of LFPs following CES showed correlation of gamma frequencies with unit activity response in all layers. More importantly, high gamma power of ECoG signals only correlated with the unit activity in lower layers (V-VI) following CES. Time-frequency correlations, which were found between LFPs, ECoGs and unit activity, were frequency- and amplitude-dependent. Significance. The signature of the neural activity observed in LFP and ECoG signals provides a better understanding of the effects of stimulation on network activity, representative of large numbers of neurons responding to stimulation. These results demonstrate that the neurorehabilitation and neuroprosthetic applications of CES targeting layered cortex can be further improved by using field potential recordings as surrogates to unit activity aimed at optimizing stimulation efficacy. Likewise, the signatures

  1. The validity of the general similarity law for electrical breakdown of gases

    International Nuclear Information System (INIS)

    Osmokrovic, Predrag; Zivic, Tamara; Loncar, Boris; Vasic, Aleksandra

    2006-01-01

    This paper investigates the validity of the similarity law in cases of dc and pulse breakdown of gases. Geometrically similar systems insulated with SF 6 gas were used during experiments. It is shown that the similarity law is valid for dc breakdown voltage if the electron mean free path is included in geometrical parameters of the system, but not for pulse breakdown voltages. The explanation for this is the mechanism of the pulse discharge. The similarity law was expanded to take into account mechanisms of pulse breakdown initiation. Thus, the general similarity law is obtained, the validity of which in case of a pulse breakdown is established experimentally

  2. General Electric Company proposed test and evaluation plan, commercial buildings. National Solar Demonstration Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-04-01

    The general requirements and methods for instrumenting, testing, and evaluating solar HVAC systems forming a part of ERDA's ''Commercial Demonstration Program'' commensurate with ERDA 23A and the Proposed Management Plan 75SDS4270 are defined. Design requirements are specified for the performance of components and subsystems comprising the instrumentation and data gathering system, as well as the support functions required to perform the diagnostic measurements, collection and processing of data, and documentation of reports on solar HVAC system performance, including economic and societal evaluations.

  3. Relativistic two-fermion problem with the most general electric and magnetic potentials

    International Nuclear Information System (INIS)

    Yilmazer, A.U.

    1986-01-01

    The energy equation of two spin-1/2 particles interacting with their charges and anomalous magnetic moments is examined. Starting with the most general Hamiltonian already obtained by other authors, the relevant wave equation has been written in terms of the generators of the de Sitter group. The radial equations for four different two-fermion systems are derived and the positronium case is studied in detail. Their bound state solutions are discussed and the similarity to the sixteen radial equations arrived at by other authors in completely different manner is pointed out. (author)

  4. Asymmetric kinetic equilibria: Generalization of the BAS model for rotating magnetic profile and non-zero electric field

    Science.gov (United States)

    Dorville, Nicolas; Belmont, Gérard; Aunai, Nicolas; Dargent, Jérémy; Rezeau, Laurence

    2015-09-01

    Finding kinetic equilibria for non-collisional/collisionless tangential current layers is a key issue as well for their theoretical modeling as for our understanding of the processes that disturb them, such as tearing or Kelvin Helmholtz instabilities. The famous Harris equilibrium [E. Harris, Il Nuovo Cimento Ser. 10 23, 115-121 (1962)] assumes drifting Maxwellian distributions for ions and electrons, with constant temperatures and flow velocities; these assumptions lead to symmetric layers surrounded by vacuum. This strongly particular kind of layer is not suited for the general case: asymmetric boundaries between two media with different plasmas and different magnetic fields. The standard method for constructing more general kinetic equilibria consists in using Jeans theorem, which says that any function depending only on the Hamiltonian constants of motion is a solution to the steady Vlasov equation [P. J. Channell, Phys. Fluids (1958-1988) 19, 1541 (1976); M. Roth et al., Space Sci. Rev. 76, 251-317 (1996); and F. Mottez, Phys. Plasmas 10, 1541-1545 (2003)]. The inverse implication is however not true: when using the motion invariants as variables instead of the velocity components, the general stationary particle distributions keep on depending explicitly of the position, in addition to the implicit dependence introduced by these invariants. The standard approach therefore strongly restricts the class of solutions to the problem and probably does not select the most physically reasonable. The BAS (Belmont-Aunai-Smets) model [G. Belmont et al., Phys. Plasmas 19, 022108 (2012)] used for the first time the concept of particle accessibility to find new solutions: considering the case of a coplanar-antiparallel magnetic field configuration without electric field, asymmetric solutions could be found while the standard method can only lead to symmetric ones. These solutions were validated in a hybrid simulation [N. Aunai et al., Phys. Plasmas (1994-present) 20

  5. Asymmetric kinetic equilibria: Generalization of the BAS model for rotating magnetic profile and non-zero electric field

    International Nuclear Information System (INIS)

    Dorville, Nicolas; Belmont, Gérard; Aunai, Nicolas; Dargent, Jérémy; Rezeau, Laurence

    2015-01-01

    Finding kinetic equilibria for non-collisional/collisionless tangential current layers is a key issue as well for their theoretical modeling as for our understanding of the processes that disturb them, such as tearing or Kelvin Helmholtz instabilities. The famous Harris equilibrium [E. Harris, Il Nuovo Cimento Ser. 10 23, 115–121 (1962)] assumes drifting Maxwellian distributions for ions and electrons, with constant temperatures and flow velocities; these assumptions lead to symmetric layers surrounded by vacuum. This strongly particular kind of layer is not suited for the general case: asymmetric boundaries between two media with different plasmas and different magnetic fields. The standard method for constructing more general kinetic equilibria consists in using Jeans theorem, which says that any function depending only on the Hamiltonian constants of motion is a solution to the steady Vlasov equation [P. J. Channell, Phys. Fluids (1958–1988) 19, 1541 (1976); M. Roth et al., Space Sci. Rev. 76, 251–317 (1996); and F. Mottez, Phys. Plasmas 10, 1541–1545 (2003)]. The inverse implication is however not true: when using the motion invariants as variables instead of the velocity components, the general stationary particle distributions keep on depending explicitly of the position, in addition to the implicit dependence introduced by these invariants. The standard approach therefore strongly restricts the class of solutions to the problem and probably does not select the most physically reasonable. The BAS (Belmont-Aunai-Smets) model [G. Belmont et al., Phys. Plasmas 19, 022108 (2012)] used for the first time the concept of particle accessibility to find new solutions: considering the case of a coplanar-antiparallel magnetic field configuration without electric field, asymmetric solutions could be found while the standard method can only lead to symmetric ones. These solutions were validated in a hybrid simulation [N. Aunai et al., Phys. Plasmas (1994-present

  6. The convergence of electric power and natural gas industries. Mergers and acquisitions in the United States

    International Nuclear Information System (INIS)

    Meritet, S.

    2000-01-01

    Deep transformations have taken place in the US electric power industry, in terms of organisation and competition. The reforms of the regulation of this sector have changed the operation rules and, as an answer, the companies have adapted their behaviour. The reorganization is characterized by the combination between new competitive markets with new occupations. The deregulation and the technical progress accelerate the reconfiguration of the industry with the convergence of the natural gas and electric power activities. Since 1996, the numerous mergers-acquisitions between companies are representative of the tight links existing between the two energy sources. In this work, the convergence of the natural gas and power industries in the US is examined. The study of the reconciliation between power and gas companies (mainly the utilities) stresses on the improvement of the combined companies efficiency. The first part deals with the reconfiguration of the US power industry. The second part analyzes the consequences of the gas-electricity mergers and acquisitions. It includes the exploitation of financial data and a classical econometric test about the 'size-scale-spread' relation. The re-composition of the value chain is at the center of the industrial economy problem: it gives the opportunity for new forms of markets and firms. (J.S.)

  7. Description of CRIB, the GIPSY retrieval mechanism, and the interface to the General Electric MARK III Service : CRIB, the mineral resources data bank of the U.S. Geological Survey--guide for public users, 1977

    Science.gov (United States)

    Calkins, James Alfred; Keefer, Eleanor K.; Ofsharick, Regina A.; Mason, George T.; Tracy, Patricia; Atkins, Mary

    1978-01-01

    The U.S. Geological Survey's Computerized Resources Information Bank (CRIB) is being made available for public use through the computer facilities of the University of Oklahoma and the General Electric Company, U.S.A. The use of General Electric's worldwide information-services network provides access to the CRIB file to a worldwide clientele. This manual, which consists of two chapters, is intended as a guide to users who wish to interrogate the file. Chapter A contains a description of the CRIB file, information on the use of the GIPSY retrieval system, and a description of the General Electric MARK III Service. Chapter B contains a description of the individual data items in the CRIB record as well as code lists. CRIB consists of a set of variable-length records on the metallic and nonmetallic mineral resources of the United States and other countries. At present, 31,645 records in the master file are being made available. The record contains information on mineral deposits and mineral commodities. Some topics covered are: deposit name, location, commodity information, description of deposit, geology, production, reserves, potential resources, and references. The data are processed by the GIPSY program, which maintains the data file and builds, updates, searches, and prints the records using simple yet versatile command statements. Searching and selecting records is accomplished by specifying the presence, absence, or content of any element of information in the record; these specifications can be logically linked to prepare sophisticated search strategies. Output is available in the form of the complete record, a listing of selected parts of the record, or fixed-field tabulations. The General Electric MARK III Service is a computerized information services network operating internationally by land lines, satellites, and undersea cables. The service is available by local telephone to 500 cities in North America, Western Europe, Australia, Southeast Asia, Japan

  8. Assessment of load of beam-balanced pumping units by electric motor power indicators

    Directory of Open Access Journals (Sweden)

    Д. И. Шишлянников

    2017-10-01

    Full Text Available The results of experimental studies on the loading of beam-balanced pumping units (BP of sucker rod- pumping equipment (SRPE are presented. It is noted that the key factor that has the most significant effect causing the SRPE failure is the balance of the beam pumping unit, which determines the amount of specific energy consumption for the rise of reservoir fluid and the level of dynamic loads on the machine units. The urgency of using software-recording systems for estimating the loading of units of oil field pumping installations is substantiated. The principle of operation and design of the «AKD-SK» software recording system is described. The prospects of using this method for controlling the performance parameters and evaluating the technical state of the sicker rod-pumping units is proved on the basis of an analysis of the magnitude and nature of the changes in the loads of drive motors determined by the registration of the instantaneous values of the consumed power. The main provisions of the methodology for analyzing the watt-meters of drive motors of the sucker rod-pumping units are outlined. The nature of the manifestation of the main defects of submersible pumps and beam-balanced pumping units is described. The results of pilot-industrial tests of the beam-balanced pumping units equipped with advanced permanent magnet motors and intelligent control stations are presented. It is proved that the use of permanent magnet motors allows to reduce the specific energy consumption for the rise of reservoir fluid, which increases the efficiency of the SRPE.However, the presence of transient processes and generator operating modes of the permanent magnet motors results in the occurrence of significant dynamic loads, which, due to the rigid fixing of the rotor of magnet motor on the reducer shaft, negatively affect the life of the gearbox bearings. It has been shown that the lack of its own bearings in the tested motors causes a high probability

  9. 48 CFR 9904.410 - Allocation of business unit general and administrative expenses to final cost objectives.

    Science.gov (United States)

    2010-10-01

    ... unit general and administrative expenses to final cost objectives. 9904.410 Section 9904.410 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE OF FEDERAL PROCUREMENT POLICY, OFFICE OF MANAGEMENT AND BUDGET PROCUREMENT PRACTICES AND COST ACCOUNTING STANDARDS COST ACCOUNTING...

  10. Allocation of Home Office Expenses to Segments and Business Unit General and Administrative Expenses to Final Cost Objectives

    Science.gov (United States)

    1992-02-16

    3 0 B. Cost Accounting Standard 418 ..................................................... 3 1 1. D efinitio n s ...objective" as an activity for which a separate measurement of cost is desired. C. Horngren , Cost Accounting . A Managerial Emphasis 21 (5th ed. 1982...Segments and Business Unit General and Administrative Expenses to Final Cost Objectives 6. AUTHOR( S ) Stephen Thomas Lynch, Major 7. PERFORMING

  11. India: General Survey Unit for World Civilization Course Curriculum Project. Fulbright-Hays Summer Seminars Abroad, 1997 (India).

    Science.gov (United States)

    Brinton, Victoria

    This unit is intended to provide high school students with a general knowledge of the history and culture of India. Lessons include: (1) "Early India"; (2) "Indian Civilization 1500 BC - 500 AD: Hinduism"; (3) "Buddhism"; (4) "Indian Empires"; (5) "Indian Empires, Continued"; (6)…

  12. One voice or different choice?: Vote defection of European Union member states in the United Nations General Assembly

    DEFF Research Database (Denmark)

    Burmester, Nicolas; Jankowski, Michael

    2018-01-01

    Existing research suggests that European Union member states are increasingly able to act in concert in the United Nations General Assembly. Based on several hundred co-ordination meetings per year, the European Union ‘speaks with one voice’ on most of the resolutions voted upon in the United...... Nations General Assembly. However, little is known about instances where the European Union member states do not vote coherently. Three questions remain unanswered. First, which aspects affect deviating voting behaviour of European Union member states? Second, who are the most frequent defectors from...... the European Union’s majority position? Third, which voting blocs within the European Union can be identified? The article answers these questions in a quantitative design by controlling for domestic factors, issues of resolutions and the position of the United States. The results suggest that domestic aspects...

  13. Mortality Analysis of Trauma Patients in General Intensive Care Unit of a State Hospital

    Directory of Open Access Journals (Sweden)

    İskender Kara

    2015-08-01

    Full Text Available Objective: The aim of this study was to determine the mortality rate and factors affecting the mortality of trauma patients in general intensive care unit (ICU of a state hospital. Material and Method: Data of trauma patients hospitalized between January 2012 and March 2013 in ICU of Konya Numune Hospital were retrospectively analyzed. Demographic characteristics and clinical data of patients were recorded. Patients were divided into two groups as survivors and dead. Mortality rate and factors affectin mortality were examined. Results: A total of 108 trauma patients were included in the study. The mortality rate of overall group was 19.4%. Median age of the patients was 44.5 years and 75.9% of them were males. Median Glasgow Coma Scale of death group was lower (5 (3-8 vs. 15 (13-15, p<0.0001, median APACHE II score was higher (20 (15-26 vs. 10 (8-13, p<0.0001 and median duration of ICU stay was longer (27 (5-62,5 vs. 2 (1-5, p<0.0001 than those in the survival group. The most common etiology of trauma was traffic accidents (47.2% and 52.7% of patients had head trauma. The rate of patients with any fracture was significantly higher in the survival group (66.7% vs. 33.3%, p=0.007. The rate of erythrocyte suspension, fresh frozen plasma, trombocyte suspension and albumin were 38.9%, 27.8%, 0.9% and 8.3%, respectively in all group. The number of patients invasive mechanically ventilated was 27.8% and median length of stay of these patients were 5 (1.75-33.5 days. The rate of operated patients was 42.6%. The rate of tracheostomy, renal replacement therapy, bronchoscopy and percutaneous endoscopic gastrostomy enforcements were higher in the death group. The advanced age (p=0.016, OR: 1.054; 95% CI: 1.010-1100 and low GCS (p<0.0001, OR: 0.583; 95% CI: 0.456-0.745 were found to be independent risk factors the ICU mortality of trauma patients in logistic regression analysis. Conclusion: We believe that the determination of these risk factors affecting

  14. Proposal for inclusion of topics of particle physics integrated electric charge through a potentially meaningful teaching units

    Directory of Open Access Journals (Sweden)

    Lisiane Barcellos Calheiro

    2014-03-01

    Full Text Available In this article the results of the analysis of free and concept maps produced are presented from the application and evaluation of a Potentially Meaningful Teaching Units – PMTU, which is a teaching sequence based on various learning theories and seeks to promote meaningful student learning. Presents, in this work, part of a research Masters in Science Education which deals with the inclusion of topics of particle physics integrated with traditional content of the third year of high school. It was implemented in a third grade high school class of a State School in Santa Maria, Rio Grande do Sul, and Brazil. The PMTU aimed to address in an integrated manner threads for Particle Physics and Electronics. A didactic sequence that integrated the topics of electric charge, atomic models, elementary particles, quantization and process electrification was applied. Such integration aimed at stimulating the interest on topics related to Modern and Contemporary Physics. It was developed using PMTU activities that aimed at promoting meaningful learning and knowledge construction in the classroom, Since the topics involved were quite complex, this made their integration a real challenge to the high school teachers, and resulted in changes in their teaching practices. Research showed that the inclusion of topics on physics of elementary particles the and electricity, through Potentially Meaningful Teaching Units, show satisfactory results in the students’ learning.

  15. A Multi-Objective Unit Commitment Model for Setting Carbon Tax to Reduce CO2 Emission: Thailand's Electricity Generation Case

    Directory of Open Access Journals (Sweden)

    Nuchjarin Intalar

    2015-07-01

    Full Text Available Carbon tax policy is a cost-effective instrument for emission reduction. However, setting the carbon tax is one of the challenging task for policy makers as it will lead to higher price of emission-intensive sources especially the utility price. In a large-scale power generation system, minimizing the operational cost and the environmental impact are conflicting objectives and it is difficult to find the compromise solution. This paper proposes a methodology of finding a feasible carbon tax rate on strategic level using the operational unit commitment model. We present a multi-objective mixed integer linear programming model to solve the unit commitment problem and consider the environmental impacts. The methodology of analyzing of the effect of carbon tax rates on the power generation, operating cost, and CO2 emission is also provided. The trade-off relationship between total operating cost and total CO2 emission is presented in the Pareto-optimal curve to analyze the feasible carbon tax rate that is influencing on electricity operating cost. The significant outcome of this paper is a modeling framework for the policy makers to determine the possible carbon tax that can be imposed on the electricity generation.

  16. Magnets and Electricity. Seychelles Integrated Science [Teacher and Pupil Booklets]. Unit 8.

    Science.gov (United States)

    Brophy, M.; Fryars, M.

    Seychelles Integrated Science (SIS), a 3-year laboratory-based science program for students (ages 11-15) in upper primary grades 7, 8, and 9, was developed from an extensive evaluation and modification of previous P7-P9 materials. This P8 SIS unit focuses on: (1) elementary concepts in magnetic theory and the role magnets and magnetism play in…

  17. Electrical and optical analysis of fast transient discharges in a pulsed corona pilot unit

    NARCIS (Netherlands)

    Blom, P.P.M.; Smulders, H.W.M.; Heesch, van E.J.M.; Laan, van der P.C.T.

    1997-01-01

    We give a detailed analysis of intense pulsed corona dis charges. CCD movies and current, voltage and energy in put measurements are the basis of the description. The discharges are generated in a 1.5 kW pilot unit, which cre ates pulsed corona discharges energized by 100 kV pulses of 200 us width,

  18. Column Generation for Transmission Switching of Electricity Networks with Unit Commitment

    DEFF Research Database (Denmark)

    Villumsen, Jonas Christoffer; Philpott, Andy B.

    2011-01-01

    This paper presents the problem of finding the minimum cost dispatch and commitment of power generation units in a transmission network with active switching.We use the term active switching to denote the use of switches to optimize network topology in an operational context. We propose a Dantzig...

  19. Electrical - light current remote monitoring, control and automation. [Coal mine, United Kingdom

    Energy Technology Data Exchange (ETDEWEB)

    Collingwood, C H

    1981-06-01

    A brief discussion is given of the application of control monitoring and automation techniques to coal mining in the United Kingdom, especially of the use of microprocessors, for the purpose of enhancing safety and productivity. Lighting systems for the coal mine is similarly discussed.

  20. Enhanced electric dipole transition in lanthanide complex with organometallic ruthenocene units.

    Science.gov (United States)

    Hasegawa, Yasuchika; Sato, Nao; Hirai, Yuichi; Nakanishi, Takayuki; Kitagawa, Yuichi; Kobayashi, Atsushi; Kato, Masako; Seki, Tomohiro; Ito, Hajime; Fushimi, Koji

    2015-05-21

    Enhanced luminescence of a lanthanide complex with dynamic polarization of the excited state and molecular motion is introduced. The luminescent lanthanide complex is composed of one Eu(hfa)3 (hfa, hexafluoroacetylacetonate) and two phosphine oxide ligands with ruthenocenyl units Rc, [Eu(hfa)3(RcPO)2] (RcPO = diphenylphosphorylruthenocene). The ruthenocenyl units in the phosphine oxide ligands play an important role of switching for dynamic molecular polarization and motion in liquid media. The oxidation states of the ruthenocenyl unit (Rc(1+)/Rc(1+)) are controlled by potentiostatic polarization. Eu(III) complexes attached with bidentate phosphine oxide ligands containing ruthenocenyl units, [Eu(hfa)3(RcBPO)] (RcBPO = 1,1'-bis(diphenylphosphoryl)ruthenocene), and with bidentate phosphine oxide ligands, [Eu(hfa)3(BIPHEPO)] (BIPHEPO =1,1'-biphenyl-2,2'-diylbis(diphenylphosphine oxide), were also prepared as references. The coordination structures and electrochemical properties were analyzed using single crystal X-ray analysis, cyclic voltammetry, and absorption spectroscopy measurements. The luminescence properties were estimated using an optoelectrochemical cell. Under potentiostatic polarization, a significant enhancement of luminescence was successfully observed for [Eu(hfa)3(RcPO)2], while no spectral change was observed for [Eu(hfa)3(RcBPO)]. In this study, the remarkable enhanced luminescence phenomena of Eu(III) complex based on the dynamic molecular motion under potentiostatic polarization have been performed.

  1. 78 FR 69367 - Golden Valley Electric Association: Healy Power Plant Unit #2 Restart

    Science.gov (United States)

    2013-11-19

    ... of Decision. SUMMARY: The Rural Utilities Service (RUS) has issued a Record of Decision (ROD) for the... financing from RUS to facilitate the restart of Unit 2 and for improvements to the Healy Plant, which... DOE and AIDEA. The decision documented in RUS's ROD is that RUS agrees to consider, subject to...

  2. 77 FR 71607 - Mobile Offshore Drilling Unit (MODU) Electrical Equipment Certification Guidance

    Science.gov (United States)

    2012-12-03

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2012-0839] Mobile Offshore Drilling... hazardous areas on foreign-flagged Mobile Offshore Drilling Units (MODUs) that have never operated, but... International Maritime Organization (IMO) Code for the Construction and Equipment of Mobile Offshore Drilling...

  3. AMERICAN ELECTRIC POWER'S CONESVILLE POWER PLANT UNIT NO.5 CO2 CAPTURE RETROFIT STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Carl R. Bozzuto; Nsakala ya Nsakala; Gregory N. Liljedahl; Mark Palkes; John L. Marion

    2001-06-30

    ALSTOM Power Inc.'s Power Plant Laboratories (ALSTOM) has teamed with American Electric Power (AEP), ABB Lummus Global Inc. (ABB), the US Department of Energy National Energy Technology Laboratory (DOE NETL), and the Ohio Coal Development Office (OCDO) to conduct a comprehensive study evaluating the technical feasibility and economics of alternate CO{sub 2} capture and sequestration technologies applied to an existing US coal-fired electric generation power plant. The motivation for this study was to provide input to potential US electric utility actions concerning GHG emissions reduction. If the US decides to reduce CO{sub 2} emissions, action would need to be taken to address existing power plants. Although fuel switching from coal to natural gas may be one scenario, it will not necessarily be a sufficient measure and some form of CO{sub 2} capture for use or disposal may also be required. The output of this CO{sub 2} capture study will enhance the public's understanding of control options and influence decisions and actions by government, regulators, and power plant owners in considering the costs of reducing greenhouse gas CO{sub 2} emissions. The total work breakdown structure is encompassed within three major reports, namely: (1) Literature Survey, (2) AEP's Conesville Unit No.5 Retrofit Study, and (3) Bench-Scale Testing and CFD Evaluation. The report on the literature survey results was issued earlier by Bozzuto, et al. (2000). Reports entitled ''AEP's Conesville Unit No.5 Retrofit Study'' and ''Bench-Scale Testing and CFD Evaluation'' are provided as companion volumes, denoted Volumes I and II, respectively, of the final report. The work performed, results obtained, and conclusions and recommendations derived therefrom are summarized.

  4. Efficiency in the United States electric industry: Transaction costs, deregulation, and governance structures

    Science.gov (United States)

    Peterson, Carl

    Transaction costs economics (TCE) posits that firms have an incentive to bypass the market mechanisms in situations where the cost of using the market is prohibitive. Vertical integration, among other governance mechanisms, can be used to minimize the transactions costs associated with the market mechanism. The study analyses different governance mechanisms, which range from complete vertical integration to the use of market mechanisms, for firms in the US electric sector. This sector has undergone tremendous change in the past decade including the introduction of retail competition in some jurisdictions. As a result of the push toward deregulation of the industry, vertically integration, while still significant in the sector, has steadily been replaced by alternative governance structures. Using a sample of 136 investor-owned electric utilities that reported data the US Federal Energy Regulatory Commission between 1996 and 2002, this study estimates firm level efficiency using Data Envelopment Analysis (DEA) and relates these estimates to governance structure and public policies. The analysis finds that vertical integration is positively related to firm efficiency, although in a non-linear fashion suggesting that hybrid governance structures tend to be associated with lower efficiency scores. In addition, while some evidence is found for negative short-term effects on firm efficiency from the choice to deregulate, this result is sensitive to DEA model choice. Further, competition in retail markets is found to be positively related to firm level efficiency, but the retreat from deregulation, which occurred after 2000, is negatively associated with firm-level efficiency. These results are important in the ongoing academic and public policy debates concerning deregulation of the electric section and indicate that vertical economies remain in the industry, but that competition has provided incentives for improving firm level efficiency.

  5. Special Inspector General for Iraq Reconstruction. Quarterly Report to the United States Congress

    National Research Council Canada - National Science Library

    Bowen, Jr, Stuart W

    2007-01-01

    .... relief and reconstruction program in Iraq. Two notable developments frame this Report. First, total relief and reconstruction investment for Iraq from all sources the United States, Iraq, and other donors passed...

  6. Application of total care time and payment per unit time model for physician reimbursement for common general surgery operations.

    Science.gov (United States)

    Chatterjee, Abhishek; Holubar, Stefan D; Figy, Sean; Chen, Lilian; Montagne, Shirley A; Rosen, Joseph M; Desimone, Joseph P

    2012-06-01

    The relative value unit system relies on subjective measures of physician input in the care of patients. A payment per unit time model incorporates surgeon reimbursement to the total care time spent in the operating room, postoperative in-house, and clinic time to define payment per unit time. We aimed to compare common general surgery operations by using the total care time and payment per unit time method in order to demonstrate a more objective measurement for physician reimbursement. Average total physician payment per case was obtained for 5 outpatient operations and 4 inpatient operations in general surgery. Total care time was defined as the sum of operative time, 30 minutes per hospital day, and 30 minutes per office visit for each operation. Payment per unit time was calculated by dividing the physician reimbursement per case by the total care time. Total care time, physician payment per case, and payment per unit time for each type of operation demonstrated that an average payment per time spent for inpatient operations was $455.73 and slightly more at $467.51 for outpatient operations. Partial colectomy with primary anastomosis had the longest total care time (8.98 hours) and the least payment per unit time ($188.52). Laparoscopic gastric bypass had the highest payment per time ($707.30). The total care time and payment per unit time method can be used as an adjunct to compare reimbursement among different operations on an institutional level as well as on a national level. Although many operations have similar payment trends based on time spent by the surgeon, payment differences using this methodology are seen and may be in need of further review. Copyright © 2012 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Onsite and Electric Backup Capabilities at Critical Infrastructure Facilities in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Julia A. [Argonne National Lab. (ANL), Argonne, IL (United States); Wallace, Kelly E. [Argonne National Lab. (ANL), Argonne, IL (United States); Kudo, Terence Y. [Argonne National Lab. (ANL), Argonne, IL (United States); Eto, Joseph H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-04-01

    The following analysis, conducted by Argonne National Laboratory’s (Argonne’s) Risk and Infrastructure Science Center (RISC), details an analysis of electric power backup of national critical infrastructure as captured through the Department of Homeland Security’s (DHS’s) Enhanced Critical Infrastructure Program (ECIP) Initiative. Between January 1, 2011, and September 2014, 3,174 ECIP facility surveys have been conducted. This study focused first on backup capabilities by infrastructure type and then expanded to infrastructure type by census region.

  8. Space Station Freedom electrical power system hardware commonality with the United States Polar Platform

    Science.gov (United States)

    Rieker, Lorra L.; Haraburda, Francis M.

    1989-01-01

    Information is presented on how the concept of commonality is being implemented with respect to electric power system hardware for the Space Station Freedom and the U.S. Polar Platform. Included is a historical account of the candidate common items which have the potential to serve the same power system functions on both Freedom and the Polar Platform. The Space Station program and objectives are described, focusing on the test and development responsibilities. The program definition and preliminary design phase and the design and development phase are discussed. The goal of this work is to reduce the program cost.

  9. Oil substitution and energy conservation in passenger transport - by the use of electric multiple units

    Energy Technology Data Exchange (ETDEWEB)

    Padiyar, K P

    1983-11-01

    India's National Transport Policy of accelerating the electrification of railways to a target of 1000 route kilometers per year and phasing out diesel engines is justified because of indigenous coal for power generation and the flexibility and better performance of electric equipment. This article examines the growth of passenger traffic and the corresponding decline in rail's share of that traffic since 1950 to illustrate the urgency of pursuing rail electrification. Traffic forecasts through the year 2000 emphasize that railway capacity is not keeping pace with demand, which results in discouraging public use. 8 tables. (DCK)

  10. Geothermal energy in the western United States and Hawaii: Resources and projected electricity generation supplies. [Contains glossary and address list of geothermal project developers and owners

    Energy Technology Data Exchange (ETDEWEB)

    1991-09-01

    Geothermal energy comes from the internal heat of the Earth, and has been continuously exploited for the production of electricity in the United States since 1960. Currently, geothermal power is one of the ready-to-use baseload electricity generating technologies that is competing in the western United States with fossil fuel, nuclear and hydroelectric generation technologies to provide utilities and their customers with a reliable and economic source of electric power. Furthermore, the development of domestic geothermal resources, as an alternative to fossil fuel combustion technologies, has a number of associated environmental benefits. This report serves two functions. First, it provides a description of geothermal technology and a progress report on the commercial status of geothermal electric power generation. Second, it addresses the question of how much electricity might be competitively produced from the geothermal resource base. 19 figs., 15 tabs.

  11. Unit 1b: A General Approach to the Teaching of Architecture

    DEFF Research Database (Denmark)

    Toft, Anne Elisabeth

    2011-01-01

    The chapter presents the overall academic aims of the teaching at Unit 1b and how these were implemented in the curriculum for 2009/2010. The section includes considerations about learning targets, method, discourse, pedagogy and didactics.......The chapter presents the overall academic aims of the teaching at Unit 1b and how these were implemented in the curriculum for 2009/2010. The section includes considerations about learning targets, method, discourse, pedagogy and didactics....

  12. Mountain Plains Learning Experience Guide: Electrical Wiring. Course: Electrical Wiring Rough-In.

    Science.gov (United States)

    Arneson, R.; And Others

    One of two individualized courses included in an electrical wiring curriculum, this course covers electrical installations that are generally hidden within the structure. The course is comprised of four units: (1) Outlet and Switch Boxes, (2) Wiring, (3) Service Entrance, and (4) Signal and Low Voltage Systems. Each unit begins with a Unit…

  13. Fuel cell assembly unit for promoting fluid service and electrical conductivity

    Science.gov (United States)

    Jones, Daniel O.

    1999-01-01

    Fluid service and/or electrical conductivity for a fuel cell assembly is promoted. Open-faced flow channel(s) are formed in a flow field plate face, and extend in the flow field plate face between entry and exit fluid manifolds. A resilient gas diffusion layer is located between the flow field plate face and a membrane electrode assembly, fluidly serviced with the open-faced flow channel(s). The resilient gas diffusion layer is restrained against entering the open-faced flow channel(s) under a compressive force applied to the fuel cell assembly. In particular, a first side of a support member abuts the flow field plate face, and a second side of the support member abuts the resilient gas diffusion layer. The support member is formed with a plurality of openings extending between the first and second sides of the support member. In addition, a clamping pressure is maintained for an interface between the resilient gas diffusion layer and a portion of the membrane electrode assembly. Preferably, the support member is spikeless and/or substantially flat. Further, the support member is formed with an electrical path for conducting current between the resilient gas diffusion layer and position(s) on the flow field plate face.

  14. Cycles in competitive electricity markets: a simulation study of the western United States

    International Nuclear Information System (INIS)

    Ford, A.

    1999-01-01

    This paper describes the potential for power plant construction to appear in waves causing alternating periods of over and under supply of electricity. The end result would be major swings in market prices as the industry moves through the phases of a construction cycle. This paper begins with some background on why these cycles should be taken seriously as we write the rules for a restructured electricity industry. It uses computer simulation to learn that cycles could emerge if the western states adopt the market rules used in California. Construction cycles are a potentially serious problem, but they are not inevitable. This paper uses computer simulation to show that cycles could be dampened substantially by introducing a constant capacity payment along side of the market clearing price for energy. The paper concludes with an examination of the consumer impacts of a constant capacity payment. Wholesale consumers would experience higher costs in the short run, but lower energy prices would nullify the impact of capacity payments in the long run. Retail consumers would not necessarily face higher costs in the short run because of a reduction in charges for recovery of stranded costs. (author)

  15. Availability of own electricity generation in processing units of small wood

    Directory of Open Access Journals (Sweden)

    R. M. Nogueira

    2014-03-01

    Full Text Available The self power generation can be an alternative, to the industries, in view of the low quality of energy supply by conventional network, especially in industries that generate waste with energy potential. Thus, the objective of this study was to compare, economically, self power generating using wood waste as fuel, with the receipt of electricity by conventional network in a small timber industry. It was determined the values of energy consumption by each equipment that is a part of industry and, based on encountered values, it was determined the actual cost of its generation, comparing its values with the prices of energy by conventional network. Based on these results can be noted that the purchase of electricity by conventional network is the most economically advantageous when compared with self power generation under the conditions studied in this work, however, even with the economic advantage of obtaining energy from the network, the generation itself becomes a sustainable alternative from the environmental and social standpoint.

  16. Optimal Topology and Experimental Evaluation of Piezoelectric Materials for Actively Shunted General Electric Polymer Matrix Fiber Composite Blades

    Science.gov (United States)

    Choi, Benjamin B.; Duffy, Kirsten; Kauffman, Jeffrey L.; Kray, Nicholas

    2012-01-01

    NASA Glenn Research Center, in collaboration with GE Aviation, has begun the development of a smart adaptive structure system with piezoelectric (PE) transducers to improve composite fan blade damping at resonances. Traditional resonant damping approaches may not be realistic for rotating frame applications such as engine blades. The limited space in which the blades reside in the engine makes it impossible to accommodate the circuit size required to implement passive resonant damping. Thus, a novel digital shunt scheme has been developed to replace the conventional electric passive shunt circuits. The digital shunt dissipates strain energy through the load resistor on a power amplifier. General Electric (GE) designed and fabricated a variety of polymer matrix fiber composite (PMFC) test specimens. Investigating the optimal topology of PE sensors and actuators for each test specimen has revealed the best PE transducer location for each target mode. Also a variety of flexible patches, which can conform to the blade surface, have been tested to identify the best performing PE patch. The active damping control achieved significant performance at target modes. This work has been highlighted by successful spin testing up to 5000 rpm of subscale GEnx composite blades in Glenn s Dynamic Spin Rig.

  17. GenLocDip: A Generalized Program to Calculate and Visualize Local Electric Dipole Moments.

    Science.gov (United States)

    Groß, Lynn; Herrmann, Carmen

    2016-09-30

    Local dipole moments (i.e., dipole moments of atomic or molecular subsystems) are essential for understanding various phenomena in nanoscience, such as solvent effects on the conductance of single molecules in break junctions or the interaction between the tip and the adsorbate in atomic force microscopy. We introduce GenLocDip, a program for calculating and visualizing local dipole moments of molecular subsystems. GenLocDip currently uses the Atoms-In-Molecules (AIM) partitioning scheme and is interfaced to various AIM programs. This enables postprocessing of a variety of electronic structure output formats including cube and wavefunction files, and, in general, output from any other code capable of writing the electron density on a three-dimensional grid. It uses a modified version of Bader's and Laidig's approach for achieving origin-independence of local dipoles by referring to internal reference points which can (but do not need to be) bond critical points (BCPs). Furthermore, the code allows the export of critical points and local dipole moments into a POVray readable input format. It is particularly designed for fragments of large systems, for which no BCPs have been calculated for computational efficiency reasons, because large interfragment distances prevent their identification, or because a local partitioning scheme different from AIM was used. The program requires only minimal user input and is written in the Fortran90 programming language. To demonstrate the capabilities of the program, examples are given for covalently and non-covalently bound systems, in particular molecular adsorbates. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. Edwin I. Hatch Nuclear Plant, Unit 2. License application, general information

    International Nuclear Information System (INIS)

    1975-01-01

    An application for a direct cycle BWR is presented. The reactor will be located about 11 miles north of Baxley, Ga., near the south bank of the Ultamaha River in Appling County close to Hatch-1 Reactor. The core thermal power level will be 2537 MW(t) and the electrical power level will be 795 MW(e). Mechanical cooling towers will be utilized

  19. The DuPont, Monsanto, General Electric open-quotes Lasagnaclose quotes Remediation Project - joint R ampersand D and financing

    International Nuclear Information System (INIS)

    Palmer, P.A.

    1995-01-01

    The Lasagna project is the first of what we expect will be several large cooperative projects between industry consortia and government to develop improved remediation technologies. In 1992, Monsanto Company began contacting other major corporations to see if they were experiencing similar difficulties in applying cost-effective, or even workable technologies for industrial site remediation. Both General Electric and DuPont were early participants in the effort to develop a meeting with the EPA to discuss technical problems faced in cleanup, research needs, and ways to accelerate development of more cost-effective techniques. This paper provides some background on how this cooperative process came to reality, what the Lasagna process is and how the cooperative arrangements and financing are structured

  20. Correlation between electrical and magnetic properties of phase-separated manganites studied with a general effective medium model

    International Nuclear Information System (INIS)

    Sacanell, J.; Quintero, M.; Parisi, F.; Ghivelder, L.; Leyva, A.G.; Levy, P.

    2007-01-01

    We have performed electrical resistivity and DC magnetization measurements as a function of temperature, on polycrystalline samples of phase-separated La 5/8- y Pr y Ca 3/8 MnO 3 (y=0.3). We have used the general effective medium theory to obtain theoretical resistivity vs. temperature curves corresponding to different fixed ferromagnetic (FM) volume fraction values, assuming that the sample is a mixture of typical metallic-like and insulating manganites. By comparing this data with our experimental resistivity curves we have obtained the relative FM volume fraction of our sample as a function of temperature. This result matches with the corresponding magnetization data in excellent agreement, showing that a mixed-phase scenario is the key element to explain both the magnetic and transport properties in the present compound

  1. Electric power monthly

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    The Energy Information Administration (EIA) prepares the Electric Power Monthly (EPM) for a wide audience including Congress, Federal and State agencies, the electric utility industry, and the general public. This publication provides monthly statistics for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fossil fuels are also displayed for the North American Electric Reliability Council (NERC) regions. The EIA publishes statistics in the EPM on net generation by energy source, consumption, stocks, quantity, quality, and cost of fossil fuels; and capability of new generating units by company and plant. The purpose of this publication is to provide energy decisionmakers with accurate and timely information that may be used in forming various perspectives on electric issues that lie ahead.

  2. Conformity to the surviving sepsis campaign international guidelines among physicians in a general intensive care unit in Nairobi.

    Science.gov (United States)

    Mung'ayi, V; Karuga, R

    2010-08-01

    There are emerging therapies for managing septic critically-ill patients. There is little data from the developing world on their usage. To determine the conformity rate for resuscitation and management bundles for septic patients amongst physicians in a general intensive care unit. Cross sectional observational study. The general intensive care unit, Aga Khan University Hospital,Nairobi. Admitting physicians from all specialties in the general intensive care unit. The physicians had high conformity rates of 92% and 96% for the fluid resuscitation and use of va so pressors respectively for the initial resuscitation bundle. They had moderate conformity rates for blood cultures prior to administering antibiotics (57%) and administration of antibiotics within first hour of recognition of septic shock (54%). There was high conformity rate to the glucose control policy (81%), use of protective lung strategy in acute lung injury/Acute respiratory distress syndrome, venous thromboembolism prophylaxis (100%) and stress ulcer prophylaxis (100%) in the management bundle. Conformity was moderate for use of sedation, analgesia and muscle relaxant policy (69%), continuous renal replacement therapies (54%) and low for steroid policy (35%), administration ofdrotrecogin alfa (0%) and selective digestive decontamination (15%). There is varying conformity to the international sepsis guidelines among physicians caring for patients in our general ICU. Since increased conformity would improve survival and reduce morbidity, there is need for sustained education and guideline based performance improvement.

  3. The "Forgotten" Pseudomomenta and Gauge Changes in Generalized Landau Level Problems: Spatially Nonuniform Magnetic and Temporally Varying Electric Fields

    Science.gov (United States)

    Konstantinou, Georgios; Moulopoulos, Konstantinos

    2017-05-01

    By perceiving gauge invariance as an analytical tool in order to get insight into the states of the "generalized Landau problem" (a charged quantum particle moving inside a magnetic, and possibly electric field), and motivated by an early article that correctly warns against a naive use of gauge transformation procedures in the usual Landau problem (i.e. with the magnetic field being static and uniform), we first show how to bypass the complications pointed out in that article by solving the problem in full generality through gauge transformation techniques in a more appropriate manner. Our solution provides in simple and closed analytical forms all Landau Level-wavefunctions without the need to specify a particular vector potential. This we do by proper handling of the so-called pseudomomentum ěc {{K}} (or of a quantity that we term pseudo-angular momentum L z ), a method that is crucially different from the old warning argument, but also from standard treatments in textbooks and in research literature (where the usual Landau-wavefunctions are employed - labeled with canonical momenta quantum numbers). Most importantly, we go further by showing that a similar procedure can be followed in the more difficult case of spatially-nonuniform magnetic fields: in such case we define ěc {{K}} and L z as plausible generalizations of the previous ordinary case, namely as appropriate line integrals of the inhomogeneous magnetic field - our method providing closed analytical expressions for all stationary state wavefunctions in an easy manner and in a broad set of geometries and gauges. It can thus be viewed as complementary to the few existing works on inhomogeneous magnetic fields, that have so far mostly focused on determining the energy eigenvalues rather than the corresponding eigenkets (on which they have claimed that, even in the simplest cases, it is not possible to obtain in closed form the associated wavefunctions). The analytical forms derived here for these

  4. Essays on empirical analysis of multi-unit auctions: Impacts of financial transmission rights on the restructured electricity industry

    Science.gov (United States)

    Zang, Hailing

    This dissertation uses recently developed empirical methodologies for the study of multi-unit auctions to test the impacts of Financial Transmission Rights (FTRs) on the competitiveness of restructured electricity markets. FTRs are a special type of financial option that hedge against volatility in the cost of transporting electricity over the grid. Policy makers seek to use the prices of FTRs as market signals to incentivize efficient investment and utilization of transmission capacity. However, prices will not send the correct signals if market participants strategically use FTRs. This dissertation uses data from the Texas electricity market to test whether the prices of FTRs are efficient to achieve such goals. The auctions studied are multi-unit, uniform-price, sealed-bid auctions. The first part of the dissertation studies the auctions on the spot market of the wholesale electricity industry. I derive structural empirical models to test theoretical predictions as to whether bidders fully internalize the effect of FTRs on profits into their bidding decisions. I find that bidders are learning as to how to optimally bid above marginal cost for their inframarginal capacities. The bidders also learn to bid to include FTRs into their profit maximization problem during the course of the first year. But starting from the second year, they deviated from optimal bidding that includes FTRs in the profit maximization problems. Counterfactual analysis show that the primary effect of FTRs on market outcomes is changing the level of prices rather than production efficiency. Finally, I find that in most months, the current allocations of FTRs are statistically equivalent to the optimal allocations. The second part of the dissertation studies the bidding behavior in the FTR auctions. I find that FTRs' strategic impact on the FTR purchasing behavior is significant for large bidders---firms exercising market power in the FTR auctions. Second, trader forecasts future FTR credit

  5. Distributional modeling and short-term forecasting of electricity prices by Generalized Additive Models for Location, Scale and Shape

    International Nuclear Information System (INIS)

    Serinaldi, Francesco

    2011-01-01

    In the context of the liberalized and deregulated electricity markets, price forecasting has become increasingly important for energy company's plans and market strategies. Within the class of the time series models that are used to perform price forecasting, the subclasses of methods based on stochastic time series and causal models commonly provide point forecasts, whereas the corresponding uncertainty is quantified by approximate or simulation-based confidence intervals. Aiming to improve the uncertainty assessment, this study introduces the Generalized Additive Models for Location, Scale and Shape (GAMLSS) to model the dynamically varying distribution of prices. The GAMLSS allow fitting a variety of distributions whose parameters change according to covariates via a number of linear and nonlinear relationships. In this way, price periodicities, trends and abrupt changes characterizing both the position parameter (linked to the expected value of prices), and the scale and shape parameters (related to price volatility, skewness, and kurtosis) can be explicitly incorporated in the model setup. Relying on the past behavior of the prices and exogenous variables, the GAMLSS enable the short-term (one-day ahead) forecast of the entire distribution of prices. The approach was tested on two datasets from the widely studied California Power Exchange (CalPX) market, and the less mature Italian Power Exchange (IPEX). CalPX data allow comparing the GAMLSS forecasting performance with published results obtained by different models. The study points out that the GAMLSS framework can be a flexible alternative to several linear and nonlinear stochastic models. - Research Highlights: ► Generalized Additive Models for Location, Scale and Shape (GAMLSS) are used to model electricity prices' time series. ► GAMLSS provide the entire dynamicaly varying distribution function of prices resorting to a suitable set of covariates that drive the instantaneous values of the parameters

  6. [Effects of the renal blood flow at different levels by transcutaneous electrical acupoint stimulation combined general anesthesia induced controlled hypotension].

    Science.gov (United States)

    Fang, Jian-Qiao; Zhang, Le-Le; Shao, Xiao-Mei

    2012-11-01

    To observe the intervention of transcutaneous electrical acupoint stimulation (TEAS) on the renal blood flow at different levels of mean arterial pressure (MAP) in controlled hypotension. Forty-two male beagle dogs were randomly divided into seven groups, i. e., the general anesthesia group, the 50% controlled group, the 40% controlled group, the 30% controlled group, the 50% experimental group, the 40% experimental group, and the 30% experimental group, 6 in each group. Beagles in the general anesthesia group were not treated with controlled hypotension, and the target MAP was achieved in those of the rest groups and maintained for 60 min. In the experimental groups, TEAS was applied to bilateral Hegu (LI4), Zusanli (ST36), Sanyinjiao (SP6), and Quchi (LI11) at 2/100 Hz with the stimulation strength of (4 +/- 1) mA starting from the stability of their physiological conditions to 60 min of maintaining the target MAP level. The changes of the renal blood flow were monitored at different time points using laser Doppler. From starting pressure control to the target MAP level, the renal blood flow was significantly lower in the 30% controlled group than in the general anesthesia group and the basic level of the same group (P blood pressure, the renal blood flow was significantly lower in the 50% controlled group, the 40% controlled group, the 30% controlled group, and the 30% experimental group than in the general anesthesia group (P blood pressure recovery, the renal blood flow restored to the basic level in the 50% controlled group, the 50% experimental group, and the 40% experimental group (P > 0.05), while it was not restored to the basic level in the 40% controlled group, the 30% controlled group, and the 30% experimental group (P renal blood flow, thus protecting the kidney.

  7. Evaluation of proposed casemix criteria as a basis for costing patients in the adult general intensive care unit.

    Science.gov (United States)

    Stevens, V G; Hibbert, C L; Edbrooke, D L

    1998-10-01

    This study analyses the relationship between the actual patient-related costs of care calculated for 145 patients admitted sequentially to an adult general intensive care unit and a number of factors obtained from a previously described consensus of opinion study. The factors identified in the study were suggested as potential descriptors for the casemix in an intensive care unit that could be used to predict the costs of care. Significant correlations between the costs of care and severity of illness, workload and length of stay were found but these failed to predict the costs of care with sufficient accuracy to be used in isolation to define isoresource groups in the intensive care unit. No associations between intensive care unit mortality, reason for admission and intensive and unit treatments and costs of care were found. Based on these results, it seems that casemix descriptors and isoresource groups for the intensive care unit that would allow costs to be predicted cannot be defined in terms of single factors.

  8. 47 CFR 76.2000 - Exclusive access to multiple dwelling units generally.

    Science.gov (United States)

    2010-10-01

    ... gated community, mobile home park, or garden apartment); provided however, that MDU shall not include... Communities, Designated 76.51 Community, Principal contour 76.5 Community unit 76.5 Consumer education-selector switches 76.66 Cross-ownership 76.501 D Definitions, Part 76 76.5 Designated communities 76.51...

  9. AUTOMOTIVE DIESEL MAINTENANCE 1. UNIT I, GENERAL INTRODUCTION TO DIESEL ENGINES.

    Science.gov (United States)

    Human Engineering Inst., Cleveland, OH.

    ONE OF A 30-MODULE COURSE DESIGNED TO UPGRADE THE JOB SKILLS AND TECHNICAL KNOWLEDGE OF DIESEL MAINTENANCE MECHANICS, THIS MATERIAL WAS DEVELOPED BY INDUSTRIAL TRAINING AND SUBJECT-MATTER SPECIALISTS AND TESTED IN INDUSTRIAL TRAINING SITUATIONS. THE PURPOSE OF THIS FIRST UNIT IS TO PROVIDE AN INTRODUCTION TO DIESEL ENGINES BY DEVELOPING AN…

  10. Special Inspector General for Iraq Reconstruction Quarterly Report to the United States Congress

    Science.gov (United States)

    2009-10-30

    United States continues to assist in se- curing courthouses and protecting judges and their families by locating judges in secure complexes...of the initiative.482 Soldiers and police who were legal residents of the Kurdistan Region but who are stationed in Ninewa cast absentee ballots in

  11. The data submitted by the United Kingdom to the United Nations Scientific Committee on the Effects of Atomic Radiation for the 1977 report to the General Assembly

    CERN Document Server

    Taylor, F E; Webb, G A M

    1976-01-01

    The United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) was established by the General Assembly in 1955 to report on the exposure of man to ionising radiation. In the subsequent twenty years the Committee has covered most aspects of the subject with repeated reviews of the levels of exposure from fallout due to weapons testing. The Committee is currently preparing a further report on doses from all sources and an evaluation of their biological effects. This is expected to be published in 1977. To aid it in compiling this report the Committee requested Member States of the UN to submit national data on a wide range of sources of exposure. The Board was asked by the Foreign and Commonwealth Office to collate the information requested from the United Kingdom. Data were available in the scientific literature on some topics, such as medical irradiation and environmental radioactivity. On some other topics, particularly occupational exposure, data have been collected but seldom publishe...

  12. 76 FR 73644 - Announcement of Requirements and Registration for the United States Surgeon General's Healthy...

    Science.gov (United States)

    2011-11-29

    ..., excessive alcohol use) and these chronic illnesses have been well established. The Surgeon General's Vision... computer, a mobile device (e.g., mobile phone, portable sensor, etc.), console, or any platform broadly...

  13. Special Inspector General for Iraq Reconstruction. Quarterly Report to the United States Congress

    Science.gov (United States)

    2011-04-30

    powerful allies they have cultivated . Th e highest levels of the In late January, Deputy Prime Minister (DPM) for Energy Aff airs Hussein al...skills to combat criminal gangs and maintain the peace. General Jassam com- mented favorably on USF-I’s ability to learn from its mistakes and cultivate ...SPECIAL INSPECTOR GENERAL FOR IRAQ RECONSTRUCTION FOCUS ON ANBAR • potato, mushroom , and strawberry fi elds In addition to these programs, Inma

  14. Some remarks regarding the procedure of the appointment of the secretary general of the United Nations

    OpenAIRE

    Novaković Marko

    2016-01-01

    Appointing Secretary-General is a process that has always been enshrined in secrecy. In 2016, due to reforms in the appointment process instigated by the president of the Security Council Mogens Lykketoft, more inclusion and transparency have been achieved, with the non-state actors being much more involved in the process. In the procedure itself, first five straw polls suggested that Antonio Guterres will be the new Secretary-General and this proved to be truth. Will this more transparent sy...

  15. Forty Years of the United Nations General Assembly Resolution 3379 (XXX) on Zionism and Racism: the Brazilian Vote as an instance of United States - Brazil Relations

    OpenAIRE

    SANTOS, NORMA BREDA DOS; UZIEL, EDUARDO

    2015-01-01

    Abstract In 1975, Brazil voted in favor of the United Nations General Assembly resolution 3379 (XXX), equating Zionism with a form of racism. Focusing on the decision-making process of president Ernesto Geisel's (1974-1979) foreign policy, "responsible pragmatism", this article discusses how the ultimate decision to vote in favor of resolution was taken taking into account mainly US-Brazil relationship. Resumo Em 1975, o Brasil votou a favor da resolução da Assembleia Geral das Nações Unid...

  16. Interest of Monitoring Diaphragmatic Electrical Activity in the Pediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Laurence Ducharme-Crevier

    2013-01-01

    Full Text Available The monitoring of electrical activity of the diaphragm (EAdi is a new minimally invasive bedside technology that was developed for the neurally adjusted ventilatory assist (NAVA mode of ventilation. In addition to its role in NAVA ventilation, this technology provides the clinician with previously unavailable and essential information on diaphragm activity. In this paper, we review the clinical interests of EAdi in the pediatric intensive care setting. Firstly, the monitoring of EAdi allows the clinician to tailor the ventilatory settings on an individual basis, avoiding frequent overassistance leading potentially to diaphragmatic atrophy. Increased inspiratory EAdi levels can also suggest insufficient support, while a strong tonic activity may reflect the patient efforts to increase its lung volume. EAdi monitoring also allows detection of patient-ventilator asynchrony. It can play a role in evaluation of extubation readiness. Finally, EAdi monitoring provides the clinician with better understanding of the ventilatory capacity of patients with acute neuromuscular disease. Further studies are warranted to evaluate the clinical impact of these potential benefits.

  17. Power unit with GT-MHR reactor plant for electricity production and district heating

    International Nuclear Information System (INIS)

    Kiryushin, A.L.; Kodochigov, N.G.; Kuzavkov, N.G.; Golovko, V.F.

    2000-01-01

    Modular helium reactor with the gas turbine (GT-MHR) is a perspective power reactor plant for the next century. The project reactor is based on experience of operation more than 50 gas-cooled reactors on carbon dioxide and helium, and also on subsequent achievements in the field of realization direct gas turbine Brayton cycle. To the beginning of 90 years, achievements in technology of gas turbines, highly effective recuperators and magnetic bearings made it possible to start development of the reactor plant project combining a safe modular gas cooled reactor and a power conversion system, realizing the highly effective Brayton cycle. The conceptual project of the commercial GT-MHR reactor plant fulfilled in 1997 by joint efforts of international firms, combines a safe modular reactor with an annular active core of prismatic fuel blocks and a power conversion system with direct gas turbine cycle. The efficiency of GT-MHR gas turbine cycle at level of about 48% makes it competitive in the electricity production market in comparison with any fossil or nuclear power stations

  18. Treatment and follow-up results of children with electrical burn who observed in burn intensive care unit

    Directory of Open Access Journals (Sweden)

    Çiğdem Aliosmanoğlu

    2011-06-01

    Full Text Available Electrical burns are infrequent relative to other injuries, but they are associated with high morbidity and mortality. The aim of this study was to assess management and follow-up results of pediatric patients’ who observed in intensive care unit and also review the precautions for preventing electrical burns.Materials and methods: Totally 22 patients aged under 17 years who were observed in the burn intensive care unit of Şanlıurfa Education and Research Hospital during the period between July 2009-October 2010. Cases were investigated retrospectively. The patients’ age, gender, total burn surface area, length of stay in hospital, musculo-skeletal system complication, cardiovascular system complication, kidney damage and attempts were recorded.Results: Of the 22 cases, 19 (86.3% were male and 3 (13.7% were female. The mean age of the patients was 11.5 years. In 10 (45.4% children burns were occurred in workplace and working area and 12 (54.6% were occurred in the home environment. Depth of burns were third degree in 10 (45.4% children and second degree in 12 (54.6%. The mean percentage of burn surface area was 25.9%. The mean length of stay in hospital was 17 days. Debridement and grafting were performed to 12 (54.6% cases and 10 (45.4% children were treated with dressings. No patient had increased creatinine kinase levels, oliguria, myoglobuinuria and arrhythmia. The mean hospitalization time was 17 days.Conclusion: Nearly half of patients underwent debridement plus grafting. None of our patients developed renal failure other severe system dysfunction.

  19. Palo Verde Generating Station, Units 4 and 5. License application, general information

    International Nuclear Information System (INIS)

    1978-01-01

    A license application for two more Palo Verde reactors, Units 4 and 5, is presented. The two PWR reactors have a nominal net generating power each of 1,270 MW(e). Containments are steel-lined prestressed cylindrical structures with hemispherical domes. The reactors are replicas of Palo Verde 1, 2 and 3 (see DOCKETS 50528, 50529 and 50530) using the standard Combustion Engineering System 80 (see DOCKET-STN-50470)

  20. Special Inspector General for Afghanistan Reconstruction (SIGAR) Quarterly Report to the United States Congress

    Science.gov (United States)

    2012-10-30

    anesthesia machines, X-ray machines, ventilators, defibrillators, and EKG /ECG machines. The contractor was also supposed to perform scheduled maintenance...to CSTC-A, Level 1 literacy provides an individual with the ability to read and write single words, count up to 1,000 and add and subtract whole...numbers. At Level 2 an individual can read and write sentences, carry out basic multiplication and division and identify units of measurement. At

  1. Special Inspector General for Afghanistan Reconstruction Quarterly Report to the United States Congress

    Science.gov (United States)

    2014-07-30

    Trainee A landfill containing furniture and other materials from the facilities at Camp Leatherneck, Helmand Province, that are not being returned to... rehabilitation of roads, road maintenance, contracting for road construction with private sector/road companies, monitoring and planning of railways...structures” in order to partner with the 135 GOVERNANCE REPORT TO THE UNITED STATES CONGRESS I JULY 30, 2014 Afghan Ministry of Rural Rehabilitation

  2. A "Neurological Emergency Trolley" reduces turnaround time for high-risk medications in a general intensive care unit.

    Science.gov (United States)

    Ajzenberg, Henry; Newman, Paula; Harris, Gail-Anne; Cranston, Marnie; Boyd, J Gordon

    2018-02-01

    To reduce medication turnaround times during neurological emergencies, a multidisciplinary team developed a neurological emergency crash trolley in our intensive care unit. This trolley includes phenytoin, hypertonic saline and mannitol, as well as other equipment. The aim of this study was to assess whether the cart reduced turnaround times for these medications. In this retrospective cohort study, medication delivery times for two year epochs before and after its implementation were compared. Eligible patients were identified from our intensive care unit screening log. Adults who required emergent use of phenytoin, hypertonic saline or mannitol while in the intensive care unit were included. Groups were compared with nonparametric analyses. 33-bed general medical-surgical intensive care unit in an academic teaching hospital. Time to medication administration. In the pre-intervention group, there were 43 patients with 66 events. In the post-intervention group, there were 45 patients with 80 events. The median medication turnaround time was significantly reduced after implementation of the neurological emergency trolley (25 vs. 10minutes, p=0.003). There was no statistically significant difference in intensive care or 30-day survival between the two cohorts. The implementation of a novel neurological emergency crash trolley in our intensive care unit reduced medication turnaround times. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. General Electric Nuclear Energy

    International Nuclear Information System (INIS)

    2001-01-01

    The ESBWR is a 1380 MWe boiling water reactor with improved operating safety margins and passive safety systems. He stated that the ESBWR derived from earlier GE plant design certification efforts and is the result of eight years of International cooperative work. He stated that the biggest challenge is to cross the regulatory hurdles associated with the inspections, tests, analyses, and acceptance criteria (ITAAC) and combined license (COL) programs. He further stated that he did not know how long it might take to license the ESBWR, in part, because the last GE design certification took about 8 to 10 years. Dr. Rao also provided a brief overview of the GE Nuclear Advance Liquid Metal S-PRISM design

  4. The impact of liberalization on the scope of efficiency improvement in electricity-generating portfolios for the United States and Switzerland

    Energy Technology Data Exchange (ETDEWEB)

    Krey, B.; Zweifel, P. [Socioeconomic Institute, Zurich (Switzerland)

    2008-09-15

    In this study, Markowitz mean-variance portfolio theory is applied to electricity-generating technologies of the United States and Switzerland. Both an investor (focused on changes in return) and a current user (focused on return in levels) view are adopted to determine efficient frontiers of electricity generation technologies in terms of expected return and risk as of 2003. Since shocks in generation costs per kWh (the inverse of returns) are correlated, Seemingly Unrelated Regression Estimation (SURE) is used to filter out the systematic components of the covariance matrix. Results suggest that risk-averse investors and risk-neutral current users in the United States are considerably closer to their efficiency frontier than their Swiss counterparts. This may be due to earlier and more thorough deregulation of electricity markets in the United States. (orig.)

  5. Prevalence and cost of hospital medical errors in the general and elderly United States populations.

    Science.gov (United States)

    Mallow, Peter J; Pandya, Bhavik; Horblyuk, Ruslan; Kaplan, Harold S

    2013-12-01

    The primary objective of this study was to quantify the differences in the prevalence rate and costs of hospital medical errors between the general population and an elderly population aged ≥65 years. Methods from an actuarial study of medical errors were modified to identify medical errors in the Premier Hospital Database using data from 2009. Visits with more than four medical errors were removed from the population to avoid over-estimation of cost. Prevalence rates were calculated based on the total number of inpatient visits. There were 3,466,596 total inpatient visits in 2009. Of these, 1,230,836 (36%) occurred in people aged ≥ 65. The prevalence rate was 49 medical errors per 1000 inpatient visits in the general cohort and 79 medical errors per 1000 inpatient visits for the elderly cohort. The top 10 medical errors accounted for more than 80% of the total in the general cohort and the 65+ cohort. The most costly medical error for the general population was postoperative infection ($569,287,000). Pressure ulcers were most costly ($347,166,257) in the elderly population. This study was conducted with a hospital administrative database, and assumptions were necessary to identify medical errors in the database. Further, there was no method to identify errors of omission or misdiagnoses within the database. This study indicates that prevalence of hospital medical errors for the elderly is greater than the general population and the associated cost of medical errors in the elderly population is quite substantial. Hospitals which further focus their attention on medical errors in the elderly population may see a significant reduction in costs due to medical errors as a disproportionate percentage of medical errors occur in this age group.

  6. Statement to the fifty-third session of the United Nations General Assembly, New York, 2 November 1998

    International Nuclear Information System (INIS)

    ElBaradei, M.

    1998-01-01

    The document reproduces the statement of the Director General of the IAEA at the fifty-third session of the United Nations General Assembly in New York, USA, on 2 November 1998. The statement focuses on the priority work of the Agency under the following main headings: contribution to peace and security (including the IAEA's strengthened safeguards system, inspections in Iraq, safeguards verifications in the Democratic People's Republic of Korea, future prospects of verification, illicit trafficking in nuclear material), co-operation for development (the Agency's technical co-operation programme), and meeting global challenges in the field of energy, the environment and nuclear safety. The statement concludes with a description of the process of management review and reform initiated by the Director General to ensure that the Agency is responding efficiently and effectively to the needs of its Member States

  7. Safety Evaluation Report related to the operation of Vogtle Electric Generating Plant, Units 1 and 2 (Docket Nos. 50-424 and 50-425)

    International Nuclear Information System (INIS)

    1987-03-01

    In June 1985, the staff of the Nuclear Regulatory Commission issued its Safety Evaluation Report (NUREG-1137) regarding the application of Georgia Power Company, Municipal Electric Authority of Georgia, Oglethorpe Power Corporation, and the City of Dalton, Georgia, for licenses to operate the Vogtle Electric Generating Plant, Units 1 and 2 (Docket Nos. 50-424 and 50-425). This sixth supplement of NUREG-1137 provides recent information regarding resolution of some of the open and confirmatory items that remained unresolved at the time the Safety Evaluation Report was issued. These areas are performance testing, reactor cooling hydraulics, loose parts monitoring, and electric power systems

  8. Safety evaluation report related to the operation of Susquehanna Steam Electric Station, Units 1 and 2 (Docket Nos. 50-387 and 50-388). Suppl.6

    International Nuclear Information System (INIS)

    1984-03-01

    In April 1981, the staff of the Nuclear Regulatory Commission issued its Safety Evaluation Report (NUREG-0776) regarding the application of the Pennsylvania Power and Light Company (the applicant and/or licensee) and the Allegheny Electric Cooperative, Inc. (co-applicant) for licenses to operate the Susquehanna Steam Electric Station, Units 1 and 2, located on a site in Luzerne County, Pennsylvania. This supplement to NUREG-0776 addresses the remaining issues that required resolution before licensing operation of Unit 2 and closes them out

  9. Analysis of impact of general-purpose graphics processor units in supersonic flow modeling

    Science.gov (United States)

    Emelyanov, V. N.; Karpenko, A. G.; Kozelkov, A. S.; Teterina, I. V.; Volkov, K. N.; Yalozo, A. V.

    2017-06-01

    Computational methods are widely used in prediction of complex flowfields associated with off-normal situations in aerospace engineering. Modern graphics processing units (GPU) provide architectures and new programming models that enable to harness their large processing power and to design computational fluid dynamics (CFD) simulations at both high performance and low cost. Possibilities of the use of GPUs for the simulation of external and internal flows on unstructured meshes are discussed. The finite volume method is applied to solve three-dimensional unsteady compressible Euler and Navier-Stokes equations on unstructured meshes with high resolution numerical schemes. CUDA technology is used for programming implementation of parallel computational algorithms. Solutions of some benchmark test cases on GPUs are reported, and the results computed are compared with experimental and computational data. Approaches to optimization of the CFD code related to the use of different types of memory are considered. Speedup of solution on GPUs with respect to the solution on central processor unit (CPU) is compared. Performance measurements show that numerical schemes developed achieve 20-50 speedup on GPU hardware compared to CPU reference implementation. The results obtained provide promising perspective for designing a GPU-based software framework for applications in CFD.

  10. Solving large scale unit dilemma in electricity system by applying commutative law

    Science.gov (United States)

    Legino, Supriadi; Arianto, Rakhmat

    2018-03-01

    The conventional system, pooling resources with large centralized power plant interconnected as a network. provides a lot of advantages compare to the isolated one include optimizing efficiency and reliability. However, such a large plant need a huge capital. In addition, more problems emerged to hinder the construction of big power plant as well as its associated transmission lines. By applying commutative law of math, ab = ba, for all a,b €-R, the problem associated with conventional system as depicted above, can be reduced. The idea of having small unit but many power plants, namely “Listrik Kerakyatan,” abbreviated as LK provides both social and environmental benefit that could be capitalized by using proper assumption. This study compares the cost and benefit of LK to those of conventional system, using simulation method to prove that LK offers alternative solution to answer many problems associated with the large system. Commutative Law of Algebra can be used as a simple mathematical model to analyze whether the LK system as an eco-friendly distributed generation can be applied to solve various problems associated with a large scale conventional system. The result of simulation shows that LK provides more value if its plants operate in less than 11 hours as peaker power plant or load follower power plant to improve load curve balance of the power system. The result of simulation indicates that the investment cost of LK plant should be optimized in order to minimize the plant investment cost. This study indicates that the benefit of economies of scale principle does not always apply to every condition, particularly if the portion of intangible cost and benefit is relatively high.

  11. The prevalence of dentin hypersensitivity in general dental practices in the northwest United States.

    Science.gov (United States)

    Cunha-Cruz, Joana; Wataha, John C; Heaton, Lisa J; Rothen, Marilynn; Sobieraj, Martin; Scott, JoAnna; Berg, Joel

    2013-03-01

    The prevalence of dentin hypersensitivity is uncertain, yet appropriate diagnosis and treatment of dentin hypersensitivity require accurate knowledge regarding its prevalence. The authors conducted a study to estimate the prevalence of dentin hypersensitivity in general dental practices and to investigate associated risk factors. The authors conducted a cross-sectional survey of 787 adult patients from 37 general dental practices within Northwest Practice-based Research Collaborative in Evidence-based DENTistry (PRECEDENT). Dentin hypersensitivity was diagnosed by means of participants' responses to a question regarding pain in their teeth and gingivae, and practitioner-investigators conducted a clinical examination to rule out alternative causes of pain. Participants recorded their pain level on a visual analog scale and the Seattle Scales in response to a one-second air blast. The authors used generalized estimating equation log-linear models to estimate the prevalence and the prevalence ratios. The prevalence of dentin hypersensitivity was 12.3 percent; patients with hypersensitivity had, on average, 3.5 hypersensitive teeth. The prevalence of dentin hypersensitivity was higher among 18- to 44-year olds than among participants 65 years or older; it also was higher in women than in men, in participants with gingival recession than in those without gingival recession and in participants who underwent at-home tooth whitening than in those who did not. Hypersensitivity was not associated with obvious occlusal trauma, noncarious cervical lesions or aggressive toothbrushing habits. One in eight participants from general practices had dentin hypersensitivity, which was a chronic condition causing intermittent, low-level pain. Patients with hypersensitivity were more likely to be younger, to be female and to have a high prevalence of gingival recession and at-home tooth whitening. Given dentin hypersensitivity's prevalence, clinicians should diagnose it only after

  12. Planning Development for a Family Planning Centre in Nursing Unit of the General Hospital of Argolida

    OpenAIRE

    Koukoufilippou J; Koinis A.

    2015-01-01

    Introduction: The family planning centres must be upgraded to a cornerstone of primary health care, and prevent, advise and protect the citizen's health while reducing hospitalization costs for hospitals. Aim: The purpose of this literature review is the family planning centre development in general hospital of Argolida that has a similar clinic. Material and Methods: Literature review was conducted of published English and Greek Articles from bibliographic databases Medline, Goog...

  13. Preparing General Purpose Forces in the United States and British Armies for Counterinsurgent Operations

    Science.gov (United States)

    2010-12-10

    Operations In Iraq: Planning, Combat, And Occupation,” Thomas Ricks’ Fiasco, and reports by Army historian Major Isaiah Wilson, and former CENCTOM J-4...established Multi-National Forces-Iraq, and Lieutenant General Thomas Metz, commander of the Army’s III Corps, assumed the mantle of Multi-National Corps...Donald P. Wright and Colonel Timothy R. Reese or Thomas Ricks’ Fiasco among other books. 18Dr. Carter Malkasian, “Counterinsurgency in Iraq: May 2003

  14. An analysis of electricity generation health risks. A United Kingdom perspective. Research Report No. 20

    International Nuclear Information System (INIS)

    Ball, D.J.; Roberts, L.E.J.; Simpson, A.C.D.

    1994-01-01

    This report deals with normalised (per GWa) health risk estimates associated with the construction, routine operation and decommissioning of seven feasible large-scale UK electricity generation options. Occupational risk estimates of prompt and delayed fatalities are the most robust of the statistics, though still subject to many sources of unavoidable uncertainty. The indications are that the occupational risks for each of the seven cycles, when combined for each cycle, currently lie in the range of about 0.1 to 0.2 to a maximum of about 1 to 2 fatalities per GWa, with tidal power and gas lying at the lower end of this range, and coal and off-shore wind at the higher end. Significant public health risks, at least of the type included within the remit of this project, were not identified for the renewable cycles. Comparisons between the nuclear and fossil cycles are fraught with difficulty. Individual radiation doses to the public from the nuclear (and fossil) cycles are insignificant compared to those from natural background radiation, but collective doses may appear significant if integrated over thousands of years and continental or global populations. Estimating health effects due to small collective doses to populations that may exist in the far future has little scientific justification, and in any event the estimates pale into insignificance when compared with those resulting from exposure to natural radiation were this to be calculated on the same basis. This problem is further compounded when comparison between nuclear and fossil cycles is attempted, since the latter produce copious quantities of either solid, liquid or gaseous effluents, which may contain heavy metals, carcinogens and known respiratory irritants, but for which neither short nor long-term public health implications have been quantified with confidence. The risks of major accidents in the UK have been considered and found to exist for most, perhaps all, of the seven options considered. Some

  15. An Evaluation of Shared Mental Models and Mutual Trust on General Medical Units: Implications for Collaboration, Teamwork, and Patient Safety.

    Science.gov (United States)

    McComb, Sara A; Lemaster, Matthew; Henneman, Elizabeth A; Hinchey, Kevin T

    2017-12-01

    This study examines nurse-physician teamwork and collaboration, a critical component in the delivery of safe patient care, on general medical units. To that end, we assess shared mental models and mutual trust, 2 coordinating mechanisms that help facilitate teamwork, among nurses and physicians working on general medical units. Data were collected from 37 nurses and 42 physicians at an urban teaching medical center in the Northeastern United States. Shared mental model questionnaire items were iteratively developed with experts' input to ensure content validity. Mutual trust items were adapted from an existing scale; items were reliable. Data were analyzed using χ and independent 2-tailed t tests. Physicians and nurses reported significant differences in their perceptions of the professional responsible for a variety of roles (e.g., advocating for the patient [P = 0.0007], identifying a near miss/error [P = 0.003]). Medication reconciliation is only role for which nurses perceive less responsibility than physicians perceive nurses have. Regarding mutual trust, both groups reported significantly more trust within their own professions; both groups reported similar levels of trust in physicians, with physicians reporting significantly less trust in their nursing colleagues than nurses perceive (P work is needed. To that end, we propose increasing knowledge about their respective roles, providing opportunities for nurse and physician collaboration through rounding or committee work and enhancing the preparedness and professionalism of interactions.

  16. Comparison of seating, powered characteristics and functions and costs of electrically powered wheelchairs in a general population of users.

    Science.gov (United States)

    Dolan, Michael John; Bolton, Megan Jennifer; Henderson, Graham Iain

    2017-10-26

    To profile and compare the seating and powered characteristics and functions of electrically powered wheelchairs (EPWs) in a general user population including equipment costs. Case notes of adult EPW users of a regional NHS service were reviewed retrospectively. Seating equipment complexity and type were categorized using the Edinburgh classification. Powered characteristics and functions, including control device type, were recorded. 482 cases were included; 53.9% female; mean duration EPW use 8.1 years (SD 7.4); rear wheel drive 88.0%; hand joystick 94.8%. Seating complexity: low 73.2%, medium 18.0%, high 8.7%. Most prevalent diagnoses: multiple sclerosis (MS) 25.3%, cerebral palsy (CP) 18.7%, muscular dystrophy (8.5%). Compared to CP users, MS users were significantly older at first use, less experienced, more likely to have mid-wheel drive and less complex seating. Additional costs for muscular dystrophy and spinal cord injury users were 3-4 times stroke users. This is the first large study of a general EPW user population using a seating classification. Significant differences were found between diagnostic groups; nevertheless, there was also high diversity within each group. The differences in provision and the equipment costs across diagnostic groups can be used to improve service planning. Implications for Rehabilitation At a service planning level, knowledge of a population's diagnostic group and age distribution can be used to inform decisions about the number of required EPWs and equipment costs. At a user level, purchasing decisions about powered characteristics and functions of EPWs and specialised seating equipment need to be taken on a case by case basis because of the diversity of users' needs within diagnostic groups. The additional equipment costs for SCI and MD users are several times those of stroke users and add between 60 and 70% of the cost of basic provision.

  17. Standard Technical Specifications General Electric plants, BWR/4:Bases (Sections 3.4-3.10). Volume 3, Revision 1

    International Nuclear Information System (INIS)

    1995-04-01

    This report documents the results of the combined effort of the NRC and the industry to produce improved Standard Technical Specifications (STS), Revision 1 for General Electric BWR/4 Plants. The changes reflected in Revision 1 resulted from the experience gained from license amendment applications to convert to these improved STS or to adopt partial improvements to existing technical specifications. This NUREG is the result of extensive public technical meetings and discussions between the Nuclear Regulatory Commission (NRC) staff and various nuclear power plant licensees, Nuclear Steam Supply System (NSSS) Owners Groups, NSSS vendors, and the Nuclear Energy Institute (NEI). The improved STS were developed based on the criteria in the Final Commission Policy Statement on Technical Specifications Improvements for Nuclear Power Reactors, dated July 22, 1993. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the specifications for all chapters and sections of the improved STS. Volume 2 contains he Bases for Chapters 2.0 and 3.0, and Sections 3.1-3.3 of the improved STS. This document, Volume 3, contains the Bases for Sections 3.4-3.10 of the improved STS

  18. Calculation of particulate dispersion in a design-basis tornadic storm from the General Electric Vallecitos Nuclear Center, Vallecitos, California

    International Nuclear Information System (INIS)

    Pepper, D.W.

    1979-11-01

    A three-dimensional numerical model is used to calculate ground-level air concentration and deposition (due to precipitation scavenging) after a hypothetical tornado strike at the General Electric Vallecitos Nuclear Center at Vallecitos, California. Plutonium particles less than 20 μm in diameter are assumed to be lifted into the tornadic storm cell by the vortex. The rotational characteristics of the tornadic storm are embedded within the larger mesoscale flow of the storm system. The design-basis translational wind values are based on probabilities associated with existing records of tornado strikes in the vicinity of the plant site. Turbulence exchange coefficients are based on empirical values deduced from experimental data in severe storms and from theoretical assumptions obtained from the literature. The method of moments is used to incorporate subgrid-scale resolution of the concentration within a grid cell volume. This method is a quasi-Lagrangian scheme which minimizes numerical error associated with advection. In all case studies, the effects of updrafts and downdrafts, coupled with scavenging of the particulates by precipitation, account for most of the material being deposited within 20 to 45 km downwind of the plant site. Ground-level isopleths in the x-y plane show that most of the material is deposited behind and slightly to the left of the centerline trajectory of the storm. Approximately 5% of the material is dispersed into the stratosphere and anvil section of the storm

  19. Calculation of particulate dispersion in a design-basis tornadic storm from the General Electric Vallecitos Nuclear Center, Vallecitos, California

    Energy Technology Data Exchange (ETDEWEB)

    Pepper, D.W.

    1979-11-01

    A three-dimensional numerical model is used to calculate ground-level air concentration and deposition (due to precipitation scavenging) after a hypothetical tornado strike at the General Electric Vallecitos Nuclear Center at Vallecitos, California. Plutonium particles less than 20 ..mu..m in diameter are assumed to be lifted into the tornadic storm cell by the vortex. The rotational characteristics of the tornadic storm are embedded within the larger mesoscale flow of the storm system. The design-basis translational wind values are based on probabilities associated with existing records of tornado strikes in the vicinity of the plant site. Turbulence exchange coefficients are based on empirical values deduced from experimental data in severe storms and from theoretical assumptions obtained from the literature. The method of moments is used to incorporate subgrid-scale resolution of the concentration within a grid cell volume. This method is a quasi-Lagrangian scheme which minimizes numerical error associated with advection. In all case studies, the effects of updrafts and downdrafts, coupled with scavenging of the particulates by precipitation, account for most of the material being deposited within 20 to 45 km downwind of the plant site. Ground-level isopleths in the x-y plane show that most of the material is deposited behind and slightly to the left of the centerline trajectory of the storm. Approximately 5% of the material is dispersed into the stratosphere and anvil section of the storm.

  20. Standard Technical Specifications General Electric plants, BWR/4: Bases (Sections 2.0-3.3). Volume 2, Revision 1

    International Nuclear Information System (INIS)

    1995-04-01

    This report documents the results of the combined effort of the NRC and the industry produce improved Standard Technical Specifications (STS), Revision 1 for General Electric BWR/4 Plants. The changes reflected in Revision 1 resulted from the experience gained from license amendment applications to convert to these improved ST or to adopt partial improvements to existing technical specifications. This NUREG is the result of extensive public technical meetings and discussions between the Nuclear Regulatory Commission (NRC) staff and various nuclear power plant licensees, Nuclear Steam Supply System (NSSS) Owners Groups, NSSS vendors, and the Nuclear Energy Institute (NEI). The improved STS were developed based on the criteria in the Final Commission Policy Statement on Technical Specifications Improvements for Nuclear Power Reactors, dated July 22, 1993. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume I contains the Specifications for all chapters and sections of the improved STS. This document, Volume 2, contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1-3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4-3.10 of the improved STS

  1. Electric power annual 1997. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-07-01

    The Electric Power Annual presents a summary of electric power industry statistics at national, regional, and State levels. The objective of the publication is to provide industry decisionmakers, government policy-makers, analysts, and the general public with data that may be used in understanding US electricity markets. The Electric Power Annual is prepared by the Electric Power Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); US Department of Energy. Volume 1 -- with a focus on US electric utilities -- contains final 1997 data on net generation and fossil fuel consumption, stocks, receipts, and cost; preliminary 1997 data on generating unit capability, and retail sales of electricity, associated revenue, and the average revenue per kilowatthour of electricity sold (based on a monthly sample: Form EIA-826, ``Monthly Electric Utility Sales and Revenue Report with State Distributions``). Additionally, information on net generation from renewable energy sources and on the associated generating capability is included in Volume 1 of the EPA.

  2. Diffusion of laparoscopic cholecystectomy among general surgeons in the United States.

    Science.gov (United States)

    Escarce, J J; Bloom, B S; Hillman, A L; Shea, J A; Schwartz, J S

    1995-03-01

    Introduced in 1989, laparoscopic cholecystectomy has rapidly become the treatment of choice for symptomatic gallstones. This study describes the diffusion of laparoscopic cholecystectomy among general surgeons; assesses the importance of various reasons for surgeons adopting the procedure; and examine the influence of surgeon, practice, and health care market characteristics on the timing of adoption. The data were obtained from a survey of a national sample of surgeons. Most surgeons (81%) adopted laparoscopic cholecystectomy by early 1992. More than three fourths of adopters identified the desire to keep up with the state-of-the-art and improved patient outcomes as very or extremely important reasons for adoption. Results of proportional hazards regression analysis indicate that individual surgeons' adoption behavior generally was consistent with expected utility maximization in an uncertain new technological environment. Of particular interest, fee-for-service payment and more competitive practice settings and markets were associated with earlier adoption. These findings suggest that the "technological imperative" and surgeons' perception of the relative clinical and financial advantages of laparoscopic cholecystectomy were important reasons for the rapid diffusion of laparoscopic cholecystectomy. Policies that accelerate current trends toward payment of physicians based on salary or capitation and promote the growth of multispecialty group practice could slow the diffusion of new physician-based product innovations in health care.

  3. Multi-parameter vital sign database to assist in alarm optimization for general care units.

    Science.gov (United States)

    Welch, James; Kanter, Benjamin; Skora, Brooke; McCombie, Scott; Henry, Isaac; McCombie, Devin; Kennedy, Rosemary; Soller, Babs

    2016-12-01

    Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective of this study was the development of a methodology to help care teams optimize alarm settings. An on-body wireless monitoring system was used to continually assess heart rate, respiratory rate, SpO 2 and noninvasive blood pressure in the general ward of ten hospitals between April 1, 2014 and January 19, 2015. These data, 94,575 h for 3430 patients are contained in a large database, accessible with cloud computing tools. Simulation scenarios assessed the total alarm rate as a function of threshold and annunciation delay (s). The total alarm rate of ten alarms/patient/day predicted from the cloud-hosted database was the same as the total alarm rate for a 10 day evaluation (1550 h for 36 patients) in an independent hospital. Plots of vital sign distributions in the cloud-hosted database were similar to other large databases published by different authors. The cloud-hosted database can be used to run simulations for various alarm thresholds and annunciation delays to predict the total alarm burden experienced by nursing staff. This methodology might, in the future, be used to help reduce alarm fatigue without sacrificing the ability to continually monitor all vital signs.

  4. A comprehensive study of economic unit commitment of power systems integrating various renewable generations and plug-in electric vehicles

    International Nuclear Information System (INIS)

    Yang, Zhile; Li, Kang; Niu, Qun; Xue, Yusheng

    2017-01-01

    Highlights: • A new UCsRP problem with flexible integrations is established. • A novel multi-zone sampling method is proposed for scenarios generation. • A meta-heuristic solving tool is introduced for solving the UCsRP problem. • A comprehensive study is conducted considering multiple weathers and seasons. • The economic effects of various scenarios are evaluated and compared. - Abstract: Significant penetration of renewable generations (RGs) and mass roll-out of plug-in electric vehicles (PEVs) will pay a vital role in delivering the low carbon energy future and low emissions of greenhouse gas (GHG) that are responsible for the global climate change. However, it is of considerable difficulties to precisely forecast the undispatchable and intermittent wind and solar power generations. The uncoordinated charging of PEVs imposes further challenges on the unit commitment in modern grid operations. In this paper, all these factors are comprehensively investigated for the first time within a novel hybrid unit commitment framework, namely UCsRP, which considers a wide range of scenarios in renewable generations and demand side management of dispatchable PEVs load. UCsRP is however an extremely challenging optimisation problem not only due to the large scale, mixed integer and nonlinearity, but also due to the double uncertainties relating to the renewable generations and PEV charging and discharging. In this paper, a meta-heuristic solving tool is introduced for solving the UCsRP problem. A key to improve the reliability of the unit commitment is to generate a range of scenarios based on multiple distributions of renewable generations under different prediction errors and extreme predicted value conditions. This is achieved by introducing a novel multi-zone sampling method. A comprehensive study considering four different cases of unit commitment problems with various weather and season scenarios using real power system data are conducted and solved, and smart

  5. Over-imaging in uncomplicated low back pain: a 12-month audit of a general medical unit.

    Science.gov (United States)

    Rego, M H; Nagiah, S

    2016-12-01

    Low back pain is frequently encountered in hospitals and is a leading cause of disability, often involving costly imaging that exposes a patient to radiation. A retrospective 12-month audit at a South Australian tertiary hospital aimed to evaluate the frequency, modality and appropriateness of imaging in patients with low back pain. Results showed that the general medical unit was unnecessarily ordering imaging in 40% of patients who exhibited no indications warranting such a procedure. A standardised protocol is required to preventing clinicians from requesting imaging solely for the purposes of self-reassurance, patient reassurance or fear of litigation. © 2016 Royal Australasian College of Physicians.

  6. Statement to the 34th session of the general conference of the International Atomic Energy Agency, 17 September 1990. Statement to the 45th session of the United Nations general assembly, 23 October 1990

    International Nuclear Information System (INIS)

    Blix, H.

    1991-01-01

    The document contains the following two statements of Hans Blix, Director General of the IAEA: Statement to the 34th Session of the General Conference of the International Atomic Energy Agency, 17 September 1990; Statement to the 45th Session of the United Nations General Assembly, 23 October 1990. A separate abstract was prepared for each of these statements

  7. Statement to the 35th session of the General Conference of the International Atomic Energy Agency 16 September 1991; Statement to the 46th session of the United Nations General Assembly 21 October 1991

    International Nuclear Information System (INIS)

    Blix, H.

    1991-01-01

    The document contains the following two statements of Hans Blix, Director General of the IAEA: Statement to the 35th session of the General Conference of the International Atomic Energy Agency, 16 September 1991; Statement to the 46th session of the United Nations General Assembly, 21 October 1991. A separate abstract was prepared for each of these statements

  8. Statement to the 38th session of the General Conference of the International Atomic Energy Agency 19 September 1994; Statement to the 49th session of the United Nations General Assemblies 17 October 1994

    International Nuclear Information System (INIS)

    Blix, H.

    1994-10-01

    The document reproduces the two statements of the IAEA Director General to the 38th Session of the General conference of the IAEA from 19 September 1994 and to the 49th Session of the United Nations General Assembly from 17 October 1994. A separate abstract was prepared for each statement

  9. The data submitted by the United Kingdom to the United Nations Scientific Committee on the Effects of Atomic Radiation for the 1977 report to the General Assembly

    International Nuclear Information System (INIS)

    Taylor, F.E.; Webb, G.A.M.; Simmonds, J.R.

    1976-10-01

    The United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) was established by the General Assembly in 1955 to report on the exposure of man to ionising radiation. In the subsequent twenty years the Committee has covered most aspects of the subject with repeated reviews of the levels of exposure from fallout due to weapons testing. The Committee is currently preparing a further report on doses from all sources and an evaluation of their biological effects. This is expected to be published in 1977. To aid it in compiling this report the Committee requested Member States of the UN to submit national data on a wide range of sources of exposure. The Board was asked by the Foreign and Commonwealth Office to collate the information requested from the United Kingdom. Data were available in the scientific literature on some topics, such as medical irradiation and environmental radioactivity. On some other topics, particularly occupational exposure, data have been collected but seldom published systematically

  10. Technical specifications: Susquehanna Steam Electric Station, Unit No. 2 (Docket No. 50-388). Appendix A to License No. NPF-22

    International Nuclear Information System (INIS)

    1984-03-01

    Susquehanna Steam Electric Station, Unit 2 Technical Specifications were prepared by the US Nuclear Regulatory Commission to set forth the limits, operating conditions, and other requirements applicable to a nuclear reactor facility as set forth in Section 50.36 of 10 CFR Part 50 for the protection of the health and safety of the public

  11. Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Salem nuclear power plant, Unit 1

    International Nuclear Information System (INIS)

    Laudenbach, D.H.

    1979-03-01

    The technical evaluation is presented for the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Salem nuclear power plant, Unit 1. Design basis criteria used to evaluate the acceptability of the system include operator action, system testability, single failure criterion, and seismic Category I and IEEE Std-279-1971 criteria

  12. Wood pellets, what else? : Greenhouse gas parity times of European electricity from wood pellets produced in the south-eastern United States using different softwood feedstocks

    NARCIS (Netherlands)

    Hanssen, Steef V.; Duden, Anna S.; Junginger, Martin; Dale, Virginia H.; van der Hilst, Floortje

    Several EU countries import wood pellets from the south-eastern United States. The imported wood pellets are (co-)fired in power plants with the aim of reducing overall greenhouse gas (GHG) emissions from electricity and meeting EU renewable energy targets. To assess whether GHG emissions are

  13. Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment.

    Science.gov (United States)

    Spadaro, Savino; Mauri, Tommaso; Böhm, Stephan H; Scaramuzzo, Gaetano; Turrini, Cecilia; Waldmann, Andreas D; Ragazzi, Riccardo; Pesenti, Antonio; Volta, Carlo Alberto

    2018-01-31

    Assessing alveolar recruitment at different positive end-expiratory pressure (PEEP) levels is a major clinical and research interest because protective ventilation implies opening the lung without inducing overdistention. The pressure-volume (P-V) curve is a validated method of assessing recruitment but reflects global characteristics, and changes at the regional level may remain undetected. The aim of the present study was to compare, in intubated patients with acute hypoxemic respiratory failure (AHRF) and acute respiratory distress syndrome (ARDS), lung recruitment measured by P-V curve analysis, with dynamic changes in poorly ventilated units of the dorsal lung (dependent silent spaces [DSSs]) assessed by electrical impedance tomography (EIT). We hypothesized that DSSs might represent a dynamic bedside measure of recruitment. We carried out a prospective interventional study of 14 patients with AHRF and ARDS admitted to the intensive care unit undergoing mechanical ventilation. Each patient underwent an incremental/decremental PEEP trial that included five consecutive phases: PEEP 5 and 10 cmH 2 O, recruitment maneuver + PEEP 15 cmH 2 O, then PEEP 10 and 5 cmH 2 O again. We measured, at the end of each phase, recruitment from previous PEEP using the P-V curve method, and changes in DSS were continuously monitored by EIT. PEEP changes induced alveolar recruitment as assessed by the P-V curve method and changes in the amount of DSS (p Recruited volume measured by the P-V curves significantly correlated with the change in DSS (r s  = 0.734, p recruitment measured using the P-V curve technique. EIT might provide useful information to titrate personalized PEEP. ClinicalTrials.gov, NCT02907840 . Registered on 20 September 2016.

  14. Statement to the 64. Regular Session of the United Nations General Assembly, 2 November 2009, New York, USA

    International Nuclear Information System (INIS)

    ElBaradei, M.

    2009-01-01

    This is the last speech of Dr. Mohamed ElBaradei to the General Assembly as Director General of the International Atomic Energy Agency. He is reviewing the achievements of the IAEA during the last 12 years of his service to the Agency as Director General. He summarizes the activities of nuclear power, nuclear safety, technical cooperation, the Programme of Action for Cancer Therapy (PACT), the technical cooperation programme, the global non-proliferation landscape (in particular Iraq and the DPRK), uranium enrichment and plutonium reprocessing, as well as nuclear disarmament. Ultimately, a new global system of collective security is needed that entails an overhaul of the United Nations system and, above all, of the Security Council. A new system in which no country feels the need to rely on nuclear weapons for its security. A new system with effective global mechanisms for conflict prevention, peacekeeping and peacemaking. An equitable and inclusive system in which security is not perceived as a zero sum game, or based on domination, or on a balance of power. A system that places human security and human solidarity at its core, that grasps our shared destiny as one human family and that enables all of us to live together free from fear and free from want. In concluding, he takes this opportunity to express his deep gratitude to the Republic of Austria for being a most gracious and supportive host country of the IAEA. He congratulates his successor, Director General-elect Yukiya Amano, and wishes him every success. He thanks the General Assembly for its support during his 12 years as Director General

  15. Spatial distribution of motor units recruited during electrical stimulation of the quadriceps muscle versus the femoral nerve.

    Science.gov (United States)

    Rodriguez-Falces, Javier; Maffiuletti, Nicola A; Place, Nicolas

    2013-11-01

    In this study we investigated differences in the spatial recruitment of motor units (MUs) in the quadriceps when electrical stimulation is applied over the quadriceps belly versus the femoral nerve. M-waves and mechanical twitches were evoked using over-the-quadriceps and femoral nerve stimulation of gradually increasing intensity from 22 young, healthy subjects. Spatial recruitment was investigated using recruitment curves of M-waves recorded from the vastus medialis (VM) and vastus lateralis (VL) and of twitches recorded from the quadriceps. At maximal stimulation intensity (Imax), no differences were found between nerve and over-the-quadriceps stimulation. At submaximal intensities, VL M-wave amplitude was higher for over-the-quadriceps stimulation at 40% Imax, and peak twitch force was greater for nerve stimulation at 60% and 80% Imax. For the VM, MU spatial recruitment during nerve and over-the-quadriceps stimulation of increasing intensity occurred in a similar manner, whereas significant differences were observed for the VL. Copyright © 2013 Wiley Periodicals, Inc.

  16. Comparative requirements for electric energy for production of hydrogen fuel and/or recharging of battery electric automobile fleets in New Zealand and the United States

    Energy Technology Data Exchange (ETDEWEB)

    Kruger, Paul [Stanford University, Stanford, CA 94305 (United States); Leaver, Jonathan D. [Department of Civil Engineering, Unitec NZ, Auckland 1142 (New Zealand)

    2010-10-15

    Within the current outlook for sustainable electric energy supply with concomitant reduction in emission of greenhouse gases, accelerated attention is focusing on the long-term development of hydrogen fuel cell and all-electric battery vehicles to provide alternative fuels to replace petroleum-derived fuels for automotive national fleets. The potential varies significantly between large industrially developed nations and smaller industrially developing nations. The requirement for additional electric energy supply from low-specific energy renewable resources and high-specific energy nuclear resources depends strongly on individual national economic, environmental, and political factors. Analysis of the additional electric energy supply required for the two potential large-scale technologies for fueling future national transportation sectors is compared for a large Organization for Economic Co-operation and Development (OECD) nation (USA) with a small OECD nation (New Zealand), normalized on a per-capita basis. (author)

  17. Adolescent Onset Psychosis: A 2-year retrospective study of adolescents admitted to a general psychiatric unit

    Directory of Open Access Journals (Sweden)

    S Paruk

    2009-12-01

    Full Text Available Background:KwaZulu-Natal had no dedicated in-patient adolescent psychiatric service during the study period and adolescents were admitted to general psychiatric wards. Aim of Study: This is a descriptive review of adolescents admitted with psychotic symptoms to a psychiatric hospital. It aims to describe their demographic profile, associated risk factors, clinical profile and management strategies utilized. Method: The files of all adolescent patients with psychotic symptoms, aged twelve to eighteen years old, admitted to a psychiatric hospital from July 2005 to June 2007 were reviewed. Results: 70 adolescents with psychosis were admitted to adult psychiatric wards over the 2 year period. The age range was 13 to 18 years old. 80% of the adolescent patients were male, 37% reported a positive family history of mental illness, 50% smoked nicotine and 61.4% reported cannabis use. The most common diagnoses were schizophrenia (30% and schizophreniform disorder (27.1%. 85.5%(60 of adolescent patients had a trial on a first generation antipsychotic and 10 patients were initiated on a second generation antipsychotic de- novo. The average length of stay in hospital was 27.8 days. 40% defaulted follow up post discharge. Conclusion: Schizophrenia was the most common diagnosis. There were high rates of cannabis use. The adolescents were managed in psychiatric wards for significant periods and the majority of patients were initiated on first-generation antipsychotics. There is a need to develop specialized inpatient adolescent psychiatric facilities and services, as well as to address the issues of co-morbid substance use and non-adherence to treatment.

  18. Potentially inappropriate medication prescribed to elderly outpatients at a general medicine unit

    Directory of Open Access Journals (Sweden)

    Christine Grützmann Faustino

    2011-03-01

    Full Text Available Objective: To establish the prevalence of potentially inappropriate medications prescribed for elderly patients, to identify the most commonly involved drugs, and to investigate whether age, sex and number of medications were related with the prescription of these drugs. Methods: Prescriptions for 1,800 elderly patients (≥ 60 years were gathered from a database. These prescriptions were written by general physicians at a tertiary level university hospital in the city of Sao Paulo, Brazil, from February to May 2008. Only one prescription per patient was considered. The prescriptions were classified according to sex and age (60-69, 70-79 and ≥ 80. The Beers criteria (2003 version were used to evaluate potentially inappropriate medications. Results: Most of the sample comprised women (66.6% with a mean age of 71.3 years. The mean prevalence of potentially inappropriate medication prescriptions was 37.6%. The 60-69 age group presented the highest prevalence (49.9%. The most frequently prescribed potentially inappropriate medications to women were carisoprodol, amitriptyline, and fluoxetine; amitriptyline, carisoprodol, fluoxetine and clonidine were prescribed more often to men. The female sex (p<0.001; OR=2.0 and number of medications prescribed (p<0.001 were associated with prescription of potentially inappropriate medications. The chance of having a prescription of these drugs was lower among patients aged over 80 years (OR=0.7. The mean number of prescribed medications for both sexes and all age groups was 7.1. The mean number of medications per patient was higher among females (p<0.001; this result was not age-dependent (p=0.285. Conclusion: The prevalence of potentially inappropriate medications was similar to previously reported values in the literature and was correlated with the female sex. The chance of having a potentially inappropriate medication prescription was lower among patients aged over 80 years. The chance of having a

  19. Electric emissions from electrical appliances

    International Nuclear Information System (INIS)

    Leitgeb, N.; Cech, R.; Schroettner, J.

    2008-01-01

    Electric emissions from electric appliances are frequently considered negligible, and standards consider electric appliances to comply without testing. By investigating 122 household devices of 63 different categories, it could be shown that emitted electric field levels do not justify general disregard. Electric reference values can be exceeded up to 11-fold. By numerical dosimetry with homogeneous human models, induced intra-corporal electric current densities were determined and factors calculated to elevate reference levels to accounting for reduced induction efficiency of inhomogeneous fields. These factors were found not high enough to allow generally concluding on compliance with basic restrictions without testing. Electric appliances usually simultaneously emit both electric and magnetic fields exposing almost the same body region. Since the sum of induced current densities is limited, one field component reduces the available margin for the other. Therefore, superposition of electric current densities induced by either field would merit consideration. (authors)

  20. Climate-related electricity demand-side management in oil-exporting countries--the case of the United Arab Emirates

    International Nuclear Information System (INIS)

    Al-Iriani, Mahmoud A.

    2005-01-01

    The oil crisis of the 1970s has increased the concern about the continuity of oil imports flow to major oil-importing developed countries. Numerous policy measures including electricity demand-side management (DSM) programs have been adopted in such countries. These measures aim at reducing the growing need for electricity power that increases the dependency on imported foreign oil and damages the environment. On the other hand, the perception that energy can be obtained at very low cost in oil-rich countries led to less attention being paid to the potential of DSM policies in these countries. This paper discusses such potential using the case of the United Arab Emirates (UAE). Since air conditioning is a major source of electric energy consumption, the relationship between climate conditions and electric energy consumption is considered. An electricity demand model is constructed using time series techniques. The fitted model seems to represent these relationships rather well. Forecasts for electricity consumption using the estimated model indicate that a small reduction in cooling degrees requirement might induce a significant reduction in electric energy demand. Hence, a DSM program is proposed with policy actions to include, among others, measures to reduce cooling degrees requirement