WorldWideScience

Sample records for unirradiated 6t ct

  1. Draft genome sequence of Lampropedia cohaerens strain CT6(T) isolated from arsenic rich microbial mats of a Himalayan hot water spring.

    Science.gov (United States)

    Tripathi, Charu; Mahato, Nitish K; Rani, Pooja; Singh, Yogendra; Kamra, Komal; Lal, Rup

    2016-01-01

    Lampropedia cohaerens strain CT6(T), a non-motile, aerobic and coccoid strain was isolated from arsenic rich microbial mats (temperature ~45 °C) of a hot water spring located atop the Himalayan ranges at Manikaran, India. The present study reports the first genome sequence of type strain CT6(T) of genus Lampropedia cohaerens. Sequencing data was generated using the Illumina HiSeq 2000 platform and assembled with ABySS v 1.3.5. The 3,158,922 bp genome was assembled into 41 contigs with a mean GC content of 63.5 % and 2823 coding sequences. Strain CT6(T) was found to harbour genes involved in both the Entner-Duodoroff pathway and non-phosphorylated ED pathway. Strain CT6(T) also contained genes responsible for imparting resistance to arsenic, copper, cobalt, zinc, cadmium and magnesium, providing survival advantages at a thermal location. Additionally, the presence of genes associated with biofilm formation, pyrroloquinoline-quinone production, isoquinoline degradation and mineral phosphate solubilisation in the genome demonstrate the diverse genetic potential for survival at stressed niches.

  2. Possible association of 3' UTR +357 A>G, IVS11-nt 93 T>C, c.1311 C>T polymorphism with G6PD deficiency.

    Science.gov (United States)

    Sirdah, Mahmoud M; Shubair, Mohammad E; Al-Kahlout, Mustafa S; Al-Tayeb, Jamal M; Prchal, Josef T; Reading, N Scott

    2017-07-01

    Glucose-6-phosphate dehydrogenase (G6PD) deficiency is a common X-linked inherited enzymopathic disorder affecting more than 500 million people worldwide. It has so far been linked to 217 distinct genetic variants in the exons and exon-intron boundaries of the G6PD gene, giving rise to a wide range of biochemical heterogeneity and clinical manifestations. Reports from different settings suggested the association of intronic and other mutations outside the reading frame of the G6PD gene with reduced enzyme activity and presenting clinical symptoms. The present study aimed to investigate any association of other variations apart of the exonic or exonic intronic boundaries in the development of G6PD deficiency. Sixty-seven unrelated Palestinian children admitted to the pediatric hospital with hemolytic crises due to G6PD deficiency were studied. In our Palestinian cohort of 67 [59 males (M) and 8 females (F)] G6PD-deficient children, previously hospitalized for acute hemolytic anemia due to favism, molecular sequencing of the G6PD gene revealed four cases (3M and 1F) that did not have any of the variants known to cause G6PD deficiency, but the 3' UTR c.*+357A>G (rs1050757) polymorphism in association with IVS 11 (c.1365-13T>C; rs2071429), and c.1311C>T (rs2230037). We now provide an additional evidence form Palestinian G6PD-deficient subjects for a possible role of 3' UTR c.*+357 A>G, c.1365-13T>C, and/or c.1311C>T polymorphism for G6PD deficiency, suggesting that not only a single variation in the exonic or exonic intronic boundaries, but also a haplotype of G6PD should considered as a cause for G6PD deficiency.

  3. Influence of side-groove root radius on the ductile fracture toughness of miniature C(T) specimens

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; Scibetta, M.

    2009-05-15

    The use of miniature C(T) specimens, MC(T), for fracture toughness measurements in the upper shelf regime has been investigated at SCK-CEN since 2004, in the framework of the Electrabel/Tractebel SCK-CEN Convention (now General Framework Agreement SUEZ-SCK-CEN). This geometry has been used and validated on both unirradiated (2004-05) and irradiated (2006) materials, mainly reactor pressure vessel (RPV) steels. While side-grooved MC(T) specimens have shown in all conditions a systematically lower tearing resistance and ductile crack initiation toughness as compared to standard-size 1TC(T) samples, the only plain-sided MC(T) specimen tested in 2005 exhibited very high ductile fracture toughness, thus pointing at a strong influence of side-grooving on the upper shelf properties of MC(T) specimens. This study investigates the influence of side-grooving on the initiation toughness and tearing resistance of MC(T) specimens, as a function of the root radius of the side-groove (ranging from 0.1 to 1 mm) and in comparison with plain-sided MC(T) and reference 1TC(T) samples. The material used is the well characterized DIN 22NiMoCr37 RPV steel, which had been used in the European project which generated the famous EURO fracture toughness data set.

  4. Results from In-pile experiments on LWR fuel rod behavior under LOCA conditions with unirradiated rods

    International Nuclear Information System (INIS)

    Sepold, L.; Karb, E.H.; Pruessmann, M.

    1981-06-01

    This report summarizes the results of the FR2-in-pile tests at KfK (Kernforschungszentrum Karlsruhe) with unirradiated test rods. The in-pile tests with the objective of investigating the influence of a nuclear environment on the mechanisms of fuel rod failure were being performed with irradiated and unirradiated single rods of a PWR design in the DK loop of the FR2 reactor. The main parameter of the test program was the burnup, ranging from 2.500 to 35.000 MWd/t. The program with unirradiated specimens comprised the series A and B with a total of 14 tests. (orig.) [de

  5. Solubility of unirradiated UO2 fuel in aqueous solutions. Comparison between experimental and calculated (EQ3/6) data

    International Nuclear Information System (INIS)

    Ollila, K.

    1995-11-01

    The solubility behaviour of unirradiated UO 2 pellets was studied under oxic (air-saturated) and anoxic (N 2 ) conditions in deionized water, in sodium bicarbonate solutions with varying bicarbonate content (60 - 600 ppm), in Allard groundwater simulating granitic fresh groundwater conditions, and in bentonite water simulating the effects of bentonite on granitic fresh groundwater (25 deg C). The release of uranium was measured during static batch dissolution experiments of long duration (2-6 years). A comparison was made with the theoretical solubility data calculated with the geochemical code EQ3/6 in order to evaluate solubility (steady state) limiting factors. (orig.) (26 refs., 32 figs., 13 tabs.)

  6. The Efficiency of Delone Coverings of the Canonical Tilings MATH {cal T}(*(A_4)) -> T^*(A4) and MATH {cal T}(*(D_6)) -> T^*(D6)

    Science.gov (United States)

    Papadopolos, Zorka; Kasner, Gerald

    This chapter is devoted to the coverings of the two quasiperiodic canonical tilings MATH {cal T}(*(A_4)) -> T^*(A4) and MATH {cal T}(*(D_6)) equiv {cal T}(*(2F)) -> T^*(D6) T^*(2F), obtained by projection from the root lattices A4 and D6, respectively. In the first major part of this chapter, in Sect. 5.2, we shall introduce a Delone covering MATH {cal C}(s_{{cal) T}(*(A_4)}) -> C^sT^*(A4) of the 2-dimensional decagonal tiling MATH {cal T}(*(A_4)) -> T^*(A4). In the second major part of this chapter, Sect. 5.3, we summarize the results related to the Delone covering of the icosahedral tiling MATH {cal T}(*(D_6)) -> T^*(D6), MATH {cal C}_{{cal T}(*(D_6)}) -> CT^*(D6) and determine the zero-, single-, and double- deckings and the resulting thickness of the covering. In the conclusions section, we give some suggestions as to how the definition of the Delone covering might be changed in order to reach some real (full) covering of the icosahedral tiling MATH {cal T}(*(D_6)) -> T^*(D6). In Section 5.2 the definition of the Delone covering is also changed in order to avoid an unnecessary large thickness of the covering.

  7. Comparison of standard and delayed imaging to improve the detection rate of ["6"8Ga]PSMA I and T PET/CT in patients with biochemical recurrence or prostate-specific antigen persistence after primary therapy for prostate cancer

    International Nuclear Information System (INIS)

    Schmuck, Sebastian; Nordlohne, Stefan; Sohns, Jan M.; Ross, Tobias L.; Bengel, Frank M.; Derlin, Thorsten; Klot, Christoph A. von; Henkenberens, Christoph; Christiansen, Hans; Wester, Hans-Juergen

    2017-01-01

    The aim of this study was to assess the value of dual-time point imaging in PET/CT for detection of biochemically recurrent or persistent prostate cancer, using the prostate-specific membrane antigen (PSMA) ligand ["6"8Ga]PSMA I and T. 240 patients who underwent a ["6"8Ga]PSMA I and T PET/CT in the context of biochemical relapse of prostate cancer were included in this retrospective analysis. Imaging consisted of a standard whole-body PET/CT (1 h p.i.), followed by delayed (3 h p.i.) imaging of the abdomen. PSA-stratified proportions of positive PET/CT results, standardized uptake values and target-to-background ratios were analyzed, and compared between standard and delayed imaging. The overall detection rates of ["6"8Ga]PSMA I and T PET/CT were 94.2, 71.8, 58.6, 55.9 and 38.9% for PSA levels of ≥2, 1 to 0.2 to <0.5, and 0.01 to 0.2 ng/mL, respectively. Although the target-to-background ratio improved significantly over time (P < 0.0001), the majority (96.6%) of all lesions suggestive of recurrent disease could already be detected in standard imaging. Delayed imaging at 3 h p.i. exclusively identified pathologic findings in 5.4% (10/184) of abnormal ["6"8Ga]PSMA I and T PET/CT scans, and exclusively detected 3.4% (38/1134) of all lesions suggestive of recurrent disease. ["6"8Ga]PSMA I and T PET/CT shows high detection rates in patients with prostate-specific antigen persistence or biochemical recurrence of prostate cancer. Delayed imaging can detect lesions with improved contrast compared to standard imaging. However, the impact on detection rates was limited in this study. (orig.)

  8. A short comparison between mT2 and mCT

    International Nuclear Information System (INIS)

    Serna, Mario

    2008-01-01

    We compare m T2 with m CT ; both are kinematic variables designed to find relationships between masses of pair-produced new states with symmetric decay chains. We find that for massless visible particles m CT equals m T2 in a particular limit. We identify advantages and disadvantages to the use of each variable. Tovey's paper on m CT also introduced a powerful concept of extracting mass information from an analysis at intermediate stages of a symmetric decay chain. We suggest that m T2 is a better tool for performing this analysis than m CT due to m T2 's better properties under initial state radiation.

  9. Proton range shift analysis on brain pseudo-CT generated from T1 and T2 MR.

    Science.gov (United States)

    Pileggi, Giampaolo; Speier, Christoph; Sharp, Gregory C; Izquierdo Garcia, David; Catana, Ciprian; Pursley, Jennifer; Amato, Francesco; Seco, Joao; Spadea, Maria Francesca

    2018-05-29

    In radiotherapy, MR imaging is only used because it has significantly better soft tissue contrast than CT, but it lacks electron density information needed for dose calculation. This work assesses the feasibility of using pseudo-CT (pCT) generated from T1w/T2w MR for proton treatment planning, where proton range comparisons are performed between standard CT and pCT. MR and CT data from 14 glioblastoma patients were used in this study. The pCT was generated by using conversion libraries obtained from tissue segmentation and anatomical regioning of the T1w/T2w MR. For each patient, a plan consisting of three 18 Gy beams was designed on the pCT, for a total of 42 analyzed beams. The plan was then transferred onto the CT that represented the ground truth. Range shift (RS) between pCT and CT was computed at R 80 over 10 slices. The acceptance threshold for RS was according to clinical guidelines of two institutions. A γ-index test was also performed on the total dose for each patient. Mean absolute error and bias for the pCT were 124 ± 10 and -16 ± 26 Hounsfield Units (HU), respectively. The median and interquartile range of RS was 0.5 and 1.4 mm, with highest absolute value being 4.4 mm. Of the 42 beams, 40 showed RS less than the clinical range margin. The two beams with larger RS were both in the cranio-caudal direction and had segmentation errors due to the partial volume effect, leading to misassignment of the HU. This study showed the feasibility of using T1w and T2w MRI to generate a pCT for proton therapy treatment, thus avoiding the use of a planning CT and allowing better target definition and possibilities for online adaptive therapies. Further improvements of the methodology are still required to improve the conversion from MRI intensities to HUs.

  10. SCT-4800T whole body X-ray CT scanner

    International Nuclear Information System (INIS)

    Okumura, Yoshitaka; Sato, Yukio; Kuwahara, Hiroshi

    1994-01-01

    A whole body X-ray CT scanner, the SCT-4800T (trade name: INTELLECT series), has been developed. This system is the first CT scanner that is combined with general radiographic functions. The general radiographic functions include a patient couch with film casette and several tube support systems along with the CT scanner. This newly designed CT scanner also features a compact and light-weight gantry with a 700 mm diameter apperture and user-friendly operater's console. The SCT-4800T brings a new level of patient and operator comfort to the emergency radiology examination site. (author)

  11. [Association study between 834+7G/A and +1332C/T polymorphisms in the growth arrest specific 6 gene and risk of severe preeclampsia in Chinese population].

    Science.gov (United States)

    Ye, Liyan; Guan, Linbo; Fan, Ping; Liu, Xinghui; Liu, Rui; Chen, Jinxin; Zhu, Yue; Wei, Xin; Liu, Yu; Bai, Huai

    2017-02-10

    To investigate the relationship between polymorphisms of the growth arrest specific 6 (GAS6) gene and severe preeclampsia in a South West Han Chinese population. Blood samples from 167 patients with severe preeclampsia and 312 normal pregnant women as controls from Han Chinese in Chengdu area were analyzed by polymerase chain reaction-restriction fragment length polymorphisms. C and T allele frequencies for +1332C/T site were 85.63% and 14.37% in the patient group, respectively, and 78.04% and 21.96% in control group, respectively. The TT genotype and variant T allelic frequencies of the +1332C/T polymorphism were significantly lower in patients with severe preeclampsia than in the control group (both Ppreeclampsia was 0.602 (95%CI: 0.401-0.904) in carriers for the variant T allele (χ 2 =6.045, P=0.014). G and A allele frequencies for 834+7G/A site were 72.75% and 27.25% in case group, respectively, and 74.36% and 25.64% in control group, respectively. The genotype and allele frequencies of the 834+7G/A polymorphism in patients with severe preeclampsia and controls showed no significant differences (both P>0.05). In addition, there was no significant association between the polymorphisms and blood pressure levels in the patient or control groups. The variant GAS6+1332 T allele is associated with a decreased risk for severe preeclampsia in a South West Han Chinese population. On the other hand, the 834+7G/A polymorphism has no effect on the severe preeclampsia.

  12. C.T. criteria of the differential diagnosis in primary retroperitoneal masses

    International Nuclear Information System (INIS)

    Pistolesi, G.F.; Procacci, C.; Caudana, R.; Bergamo Andreis, I.A.; Manera, V.; Recla, M.; Grasso, G.; Florio, C.

    1984-01-01

    This personal series of 44 primary retroperitoneal masses (P.R.P.M.) studied by C.T. is analyzed. The reliability of C.T. in the identification (44/44), characterization (43/44) and origin evaluation (41/44) of P.R.P.M. has been absolutely satisfactory. In particular, those criteria of C.T. diagnosis which may be utilized in the evaluation of the origin of upper abdominal masses are thoroughly described. The evaluation of the involvement (non invasive; invasive) of adjacent viscera has been achieved in 22/38 P.R.P.M. verified at operation. The evaluation of tumour resectability has been less reliable due to the high incidence of under-diagnosis (60% in our personal experience). C.T. may be used in addition as an aid to different diagnostic techniques (percutaneous guided needle biopsy) or to therapy (drainage of retroperitoneal abscesses). C.T. is absolutely necessary in the follow-up of P.R.P.M. after surgery, radiotherapy or chemotherapy. (orig.)

  13. Interleukin-1β-31C/T and -511T/C polymorphisms were associated with preeclampsia in Chinese Han population.

    Directory of Open Access Journals (Sweden)

    Xuefeng Wang

    Full Text Available OBJECTIVE: The purpose of our study is to investigate the relationship between IL-1β -31C/T (rs1143627 and -511T/C (rs16944 polymorphisms and the preeclampsia (PE, and analyze the Linkage disequilibrium (LD and haplotype frequency of the two polymorphism loci. METHODS: Polymorphisms at -31C/T and -511T/C of IL-1β were genotyped with the method of polymerase chain reaction-restriction fragment length polymorphism (PCR- RFLP in 232 PE and 447 control subjects. Genotype and allele frequencies between case-control groups were compared by chi-square(X2 tests. Two-point LD and haplotype frequency analyses were done with the software Haploview4.2. RESULTS: Significant statistical differences were found between PE and control groups regarding genotype and allele frequencies of the two polymorphisms of IL-1β (For IL-1β -31C/T: X2 = 11.478, P = 0.003; For IL-1β-511T/C: X2 = 9.687, P = 0.008. LD analysis revealed that the IL-1β -31C/T SNP was in high LD with the IL-1β-511C/T SNP(D' = 0.92, r2 = 0.79. Both CT and TC haplotypes showed significant differences between case and control groups. Only the plasma level of Prothrombin Time had a significantly statistical difference among TT, CT and CC groups of the preeclamptic two polymorphisms of IL-1β-31C/T and -511T/C (for IL-1β-31C/T, F = 1.644, P = 0.01; F = 1.587, P = 0.016. CONCLUSION: Our results revealed IL-1β was associated with the PE in Chinese Han population. The CT haplotype may increase the risk of PE, while haplotype TC could be considered as a protective haplotype of PE.

  14. Radiation quality-dependence of bystander effect in unirradiated fibroblasts is associated with TGF-β1-Smad2 pathway and miR-21 in irradiated keratinocytes

    Science.gov (United States)

    Yin, Xiaoming; Tian, Wenqian; Wang, Longxiao; Wang, Jingdong; Zhang, Shuyu; Cao, Jianping; Yang, Hongying

    2015-01-01

    Traditional radiation biology states that radiation causes damage only in cells traversed by ionizing radiation. But radiation-induced bystander effect (RIBE), which refers to the biological responses in unirradiated cells when the neighboring cells are exposed to radiation, challenged this old dogma and has become a new paradigm of this field. By nature, RIBEs are the consequences of intercellular communication between irradiated and unirradiated cells. However, there are still some important questions remain unanswered such as whether RIBE is dependent on radiation quality, what are the determining factors if so, etc. Using a transwell co-culture system, we found that HaCaT keratinocytes irradiated with α-particles but not X-rays could induce bystander micronucleus formation in unirradiated WS1 fibroblasts after co-culture. More importantly, the activation of TGF-β1-Smad2 pathway and the consistent decrease of miR-21 level in α-irradiated HaCaT cells were essential to the micronucleus induction in bystander WS1 cells. On the other hand, X-irradiation did not induce bystander effect in unirradiated WS1 cells, accompanied by lack of Smad2 activation and consistent decrease of miR-21 in X-irradiated HaCaT cells. Taken together, these results suggest that the radiation quality-dependence of bystander effect may be associated with the TGF-β1-Smad2 pathway and miR-21 in irradiated cells. PMID:26080011

  15. Performance of highly sensitive cardiac troponin T assay to detect ischaemia at PET-CT in low-risk patients with acute coronary syndrome: a prospective observational study.

    Science.gov (United States)

    Morawiec, Beata; Fournier, Stephane; Tapponnier, Maxime; Prior, John O; Monney, Pierre; Dunet, Vincent; Lauriers, Nathalie; Recordon, Frederique; Trana, Catalina; Iglesias, Juan-Fernando; Kawecki, Damian; Boulat, Olivier; Bardy, Daniel; Lamsidri, Sabine; Eeckhout, Eric; Hugli, Olivier; Muller, Olivier

    2017-07-10

    Highly sensitive troponin T (hs-TnT) assay has improved clinical decision-making for patients admitted with chest pain. However, this assay's performance in detecting myocardial ischaemia in a lowrisk population has been poorly documented. To assess hs-TnT assay's performance to detect myocardial ischaemia at positron emission tomography/CT (PET-CT) in low-risk patients admitted with chest pain. Patients admitted for chest pain with a nonconclusive ECG and negative standard cardiac troponin T results at admission and after 6 hours were prospectively enrolled. Their hs-TnT samples were at T0, T2 and T6. Physicians were blinded to hs-TnT results. All patients underwent a PET-CT at rest and during adenosine-induced stress. All patients with a positive PET-CT result underwent a coronary angiography. Forty-eight patients were included. Six had ischaemia at PET-CT. All of them had ≥1 significant stenosis at coronary angiography. Areas under the curve (95% CI) for predicting significant ischaemia at PET-CT using hs-TnT were 0.764 (0.515 to 1.000) at T0, 0.812(0.616 to 1.000) at T2 and 0.813(0.638 to 0.989) at T6. The receiver operating characteristicbased optimal cut-off value for hs-TnT at T0, T2 and T6 needed to exclude significant ischaemia at PET-CT was <4 ng/L. Using this value, sensitivity, specificity, positive and negative predictive values of hs-TnT to predict significant ischaemia were 83%/38%/16%/94% at T0, 100%/40%/19%/100% at T2 and 100%/43%/20%/100% at T6, respectively. Our findings suggest that in low-risk patients, using the hs-TnT assay with a cut-off value of 4 ng/L demonstrates excellent negative predictive value to exclude myocardial ischaemia detection at PET-CT, at the expense of weak specificity and positive predictive value. ClinicalTrials.gov Identifier: NCT01374607. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly

  16. Incorporating multislice imaging into x-ray CT polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, H., E-mail: holly.johnston@utsw.edu [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2 (Canada); Hilts, M. [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2, Canada and Medical Physics, BC Cancer Agency, Vancouver Island Centre, Victoria, British Columbia V8R 6V5 (Canada); Jirasek, A. [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2, Canada and Department of Physics, University of British Columbia—Okanagan Campus, Kelowna, British Columbia V1V 1V7 (Canada)

    2015-04-15

    Purpose: To evaluate multislice computed tomography (CT) scanning for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD) and to establish a baseline assessment of image noise and uniformity in an unirradiated gel dosimeter. Methods: A 16-slice CT scanner was used to acquire images through a 1 L cylinder filled with water. Additional images were collected using a single slice machine. The variability in CT number (N{sub CT}) associated with the anode heel effect was evaluated and used to define a new slice-by-slice background subtraction artifact removal technique for CT PGD. Image quality was assessed for the multislice system by evaluating image noise and uniformity. The agreement in N{sub CT} for slices acquired simultaneously using the multislice detector array was also examined. Further study was performed to assess the effects of increasing x-ray tube load on the constancy of measured N{sub CT} and overall scan time. In all cases, results were compared to the single slice machine. Finally, images were collected throughout the volume of an unirradiated gel dosimeter to quantify image noise and uniformity before radiation is delivered. Results: Slice-by-slice background subtraction effectively removes the variability in N{sub CT} observed across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image noise was higher for the multislice system compared to the single slice scanner, but overall image quality was comparable between the two systems. Further study showed N{sub CT} was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thicknesses examined. In addition, the multislice system was found to eliminate variations in N{sub CT} due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to

  17. Plant-scale anodic dissolution of unirradiated N-Reactor fuel

    International Nuclear Information System (INIS)

    Gay, E.C.; Miller, W.E.; Laidler, J.J.

    1995-01-01

    Anodic dissolution tests were made with unirradiated N-Reactor fuel to determine the fuel segment length, diameter, and shape required for high throughput electrorefiner treatment for ultimate disposal in a geologic repository. Based on these tests, a conceptual design was produced of an electrorefiner for a full-scale plant to process N-Reactor spent fuel. In this design, the diameter of an electrode assembly is about 0.6 m (25 in.). Eight of these assemblies in an electrorefiner would accommodate a 1.333-metric-ton batch of N-Reactor fuel. Electrorefining would proceed at a rate of 40 kg uranium per hour

  18. Transport insurance of unirradiated nuclear fuels

    International Nuclear Information System (INIS)

    Matto, H.

    1985-01-01

    Special conditions must be taken into account in transport insurance for nuclear materials even if the nuclear risk involved is negligible, as in shipments of unirradiated nuclear fuels. The shipwreck of the 'Mont Louis' has raised a number of open points which must be solved pragmatically within the framework of transport insurance. Some proposals are outlined in the article. (orig.) [de

  19. Temperature dependence of magnetoresistance in neutron-irradiated and unirradiated high resistivity p-type silicon

    International Nuclear Information System (INIS)

    Yildirim, M.; Efeoglu, H.; Abay, B.; Yogurtcu, Y.K.

    1996-01-01

    The temperature dependence of the transverse magnetoresistance in irradiated and unirradiated p-type Si is studied in the range from 120 to 290 K. The magnetoresistance coefficients for the unirradiated left angle 001 right angle and left angle 1 anti 10 right angle samples increases with decreasing sample temperature in the range from 160 to 290 K, however, this behavior is reversed below 160 K. It is proposed that this reversal is due to the double injection effect. The magnetoresistance coefficient for the irradiated left angle 001 right angle sample increases with decreasing sample temperature in the range of 120 to 290 K and is greater than that for the unirradiated left angle 001 right angle sample. This result can be explained by increased scattering due to the increased number of defects produced by irradiation. On the other hand, the magnetoresistance coefficient for the unirradiated left angle 1 anti 10 right angle sample is found to be greater than that of the unirradiated left angle 001 right angle sample. (orig.)

  20. Occult cerebral vascular malformation: High-field (2.0 T) MR imaging and comparison with CT

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Chung, Jin Wook; Han, Moon Hee; Kang, Heung Sik; Han, Man Chung; Kim, Chu Wan

    1989-01-01

    Extensive experience with CT has led to the recognition of criteria for the diagnosis of occult cerebral vascular malformation. MR demonstrated all lesions as hemorrhage foci. The most common and typical MR findings of OVCM was circumscribed thick hypointense rim on T2-weighted images (T2-Wls) representing hemosiderin deposit with various central intensities suggesting the presence of hematomas in different stages (11 lesions). Among these. the recurrent hemorrhage in small amount produced the characteristic 'a bunch of grape' appearance. But, small OCVM less than 1 cm in diameter was identified as a small homogeneous hypointense nodule on T2-Wls with sharp (6 lesions) or fade-out (1 lesions) border. There were 2 lesions showing atypical findings such as dense hemosiderin rin with central lacuma or bilobed subacute hematoma. As the associated MR findings which strongly suggest the diagnosis of OCVM signal void due to feeding or draining vessels was found in 4, lesions and the surrounding focal cortical atrophy or leukomalacia in 2 lesions. The predilection site of OCVM was subcortical (8 lesions) and periventricular (6 cases) location. CT depicted 16 of the 20 lesions, but missed 4 lesions of small OCVM. CT alone did not permit definitive diagnosis of OCVM is most cases. Fifteen lesions demonstrated on CT contained somewhat hyperdense area in central or peripheral locations. Peripheral hyperdense area corresponded to the dense hemosiderin deposit on MR and central one to the hematoma formed by recent hemorrhage. Low density area on CT usually corresponded to liquefied subacute hematoma on MR

  1. Association between VEGF polymorphisms (936c/t, -460t/c and -634g/c) with haplotypes and coronary heart disease susceptibility.

    Science.gov (United States)

    Han, Xia; Liu, Lili; Niu, Jiamin; Yang, Jun; Zhang, Zengtang; Zhang, Zhiqiang

    2015-01-01

    Our aim was to investigate the association between single nucleotide polymorphisms (SNPs) of vascular endothelial growth factor (VEGF) and coronary heart disease (CHD) susceptibility in Chinese Han population. 144 CHD patients and 150 healthy individuals were enrolled in the study. Three SNPs (936C/T, -460T/C and -634G/C) of VEGF were chose and then were genotyped with Sequenom time-of-flight mass spectrometry (TOFMS). Odds ratio (OR) with 95% confidence interval (CI) were used to evaluate the association of genotypes and haplotypes and CHD susceptibility. The frequencies of -460T/C CC genotype (13.6%) was found higher in the case group than that of control group (6.7%), which indicated that CC genotype was a risk factor for CHD (OR=2.50, 95% CI=1.10-5.68). Correspondently, the C allele appeared to increase the risk of CHD (OR=1.54, 95% CI=1.07-2.22). For -634G/C polymorphism, the risk of the CC genotype carrier for CHD increased 2.24 fold compared to the wild genotype. Moreover, -634G/CC allele was significantly associated with CHD susceptibility (OR=1.65, 95% CI=1.15-2.36). In addition, +936C/T CT genotype and C allele appeared to be a genetic-susceptibility factors for CHD (OR=2.43, 95% CI=1.44-4.10; OR=1.95, 95% CI=1.26-3.02). The haplotype analysis showed that T-C-T, C-C-C and C-G-C haplotypes all could increase the risk for CHD (OR: 2.43, 2.77 and 2.33). we concluded VEGF polymorphisms were associated with CHD susceptibility. Moreover, the haplotypes of T-C-T, C-C-C and C-G-C all could increase the risk for CHD.

  2. The silent mutation MLH1 c.543C>T resulting in aberrant splicing can cause Lynch syndrome: a case report.

    Science.gov (United States)

    Yamaguchi, Tatsuro; Wakatsuki, Tomokazu; Kikuchi, Mari; Horiguchi, Shin-Ichiro; Akagi, Kiwamu

    2017-06-01

    The proband was a 67-year-old man with transverse and sigmoid colon cancer. Microsatellite instability analysis revealed a high frequency of microsatellite instability, and immunohistochemical staining showed the absence of both MLH1 and PMS2 proteins in the sigmoid colon cancer tissue specimens from the patient. DNA sequencing revealed a nucleotide substitution c.543C>T in MLH1, but this variant did not substitute an amino acid. The MLH1 c.543C>T variant was located 3 bases upstream from the end of exon 6 and created a new splice donor site 4 bases upstream from the end of exon 6. Consequently, the last 4 bases of exon 6 were deleted and frameshift occurred. Thus, the MLH1 c.543C>T silent mutation is considered 'pathogenic'. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Effect of tensile properties on time-dependent C(t) and J(t) integrals in elastic-plastic-creep FE analysis

    International Nuclear Information System (INIS)

    Lee, So-Dam; Lee, Han-Sang; Kim, Yun-Jae; Ainsworth, Robert A.; Dean, David W.

    2016-01-01

    This technical note presents the effect of elastic-plastic properties on calculated time-dependent C(t) and J(t) values. This is investigated via systematic elastic-plastic-creep finite element (FE) analysis. Three different stress-strain curves are used, having essentially the same plastic properties at large strains but different tensile data near the 0.2% proof (yield) strength. It is found that the plastic property in stress-strain curve affects the FE C(t) values only at short times (within approximately 20% of the redistribution time). The plastic property affects the initial J values at time t = 0 but not the rate of change of J(t) with time. - Highlights: • The effect of elastic-plastic properties on calculated time-dependent C(t) and J(t) values is presented via FE analysis. • The plastic property affects the FE C(t) values only at short times up to ∼20% of the redistribution time. • The plastic property affects the initial J values at time t = 0 but not the rate of change of J(t) with time.

  4. Plant-scale anodic dissolution of unirradiated N-Reactor fuel

    International Nuclear Information System (INIS)

    Gay, E.C.; Miller, W.E.; Laidler, J.J.

    1995-01-01

    Anodic dissolution tests were made with unirradiated N-Reactor fuel to determine the fuel segment length, diameter, and shape required for high throughput electro-refiner treatment for ultimate disposal in a geologic repository. Based on these tests, a conceptual design was produced of an electro-refiner for a full-scale plant to process N-Reactor spent fuel. In this design, the diameter of an electrode assembly is about 0.6 m (25 in.). Eight of these assemblies in an electro-refiner would accommodate a 1.333-metric-ton batch of N-Reactor fuel. Electrorefining would proceed at a rate of 40 kg uranium per hour. (author)

  5. Association of exudative age-related macular degeneration with matrix metalloproteinases-2 (-1306 C/T rs243865 gene polymorphism

    Directory of Open Access Journals (Sweden)

    Rasa Liutkeviciene

    2018-01-01

    Full Text Available Purpose: Age-related macular degeneration (AMD is a disease of the macula that significantly affects eyesight and leads to irreversible central vision loss. Recent studies have demonstrated that angiogenesis is the most important mechanism of AMD development. It is associated with extracellular remodeling involving different proteolytic systems, among them matrix metalloproteinases (MMPs, which play an essential role in the etiopathogenesis of AMD. The main objective of the present study was to determine the relationship between exudative AMD and MMP-2 (-1306 C/T rs243865 polymorphism. Methods: The study enrolled 267 patients with exudative AMD and 318 controls. DNA was extracted from peripheral venous blood leukocytes by commercial kits. Genotyping of MMP-2 (-1306 C/T rs243865 was carried out using real-time polymerase chain reaction method. Results: The analysis of MMP-2 (-1306 C/T polymorphism did not reveal any differences in the distribution of CC, CT, and TT genotypes between the exudative AMD and control groups: 58.8%, 31.5% and 9.7% vs. 59.75%, 33.96% and 6.29%, respectively, P = 0.287. When the study population was subdivided into age groups, MMP-2 (-1306 C/T rs243865 CT genotype showed 5.7-fold increased the risk of exudative AMD development compared to CC and TT genotypes together in younger (<65 years males group (P = 0.05. Conclusion: MMP-2 (-1306 C/T polymorphism is associated with exudative AMD development in younger males.

  6. Comparison of the growth of Listeria monocytogenes in unirradiated and irradiated cook-chill roast beef and gravy at refrigeration temperatures

    International Nuclear Information System (INIS)

    Grant, I.R.; Nixon, C.R.; Patterson, M.F.

    1993-01-01

    Specific growth rates of two strains of Listeria monocytogenes in unirradiated and irradiated (2 kGy) roast beef and gravy stored at 5° and 10°C were found to be similar. However, exponential growth of L. monocytogenes after irradiation was preceded by an extended lag period of 6–9 d at 5°C and 3–4 d at 10°C, compared with lag periods of 1–2 d and <0.1 d in unirradiated beef and gravy stored similarly

  7. Revised ANL-reported tensile data for unirradiated and irradiated (FFTF, HFIR) V-Ti and V-Cr-Ti alloys

    International Nuclear Information System (INIS)

    Billone, M.C.

    1998-01-01

    The tensile data for all unirradiated and irradiated vanadium alloys samples tested at Argonne National Laboratory (ANL) have been critically reviewed and, when necessary, revised. The review and revision are based on reanalyzing the original load-displacement strip chart recordings by a methodology consistent with current ASTM standards. For unirradiated alloys (162 samples), the revised values differ from the previous values as follows: -11±19 MPa (-4±6%) for yield strength (YS), -3±15 MPa (-1±3%) for ultimate tensile strength (UTS), -5±2% strain for uniform elongation (UE), and -4±2% strain for total elongation (TE). Of these changes, the decrease in -1±6 MPa (0±1%) for UTS, -5±2% for UE, and -4±2% for TE. Of these changes, the decrease in UE values for alloys irradiated and tested at 400--435 C is the most significant. This decrease results from the proper subtraction of nongauge-length deformation from measured crosshead deformation. In previous analysis of the tensile curves, the nongauge-length deformation was not correctly determined and subtracted from the crosshead displacement. The previously reported and revised tensile values for unirradiated alloys (20--700 C) are tabulated in Appendix A. The revised tensile values for the FFTF-irradiated (400--600 C) and HFIR-irradiated (400 C) alloys are tabulated in Appendix B, along with the neutron damage and helium levels. Appendix C compares the revised values to the previously reported values for irradiated alloys. Appendix D contains previous and revised values for the tensile properties of unirradiated V-5Cr-5Ti (BL-63) alloy exposed to oxygen

  8. Functional recovery in the irradiated kidney following removal of the contralateral unirradiated kidney

    International Nuclear Information System (INIS)

    Robbins, M.E.C.; Hopewell, J.W.; Golding, S.J.

    1986-01-01

    Radiation-induced damage to one kidney in the pig causes a fall in total renal function; this would be recognised and lead to a compensatory response in the unirradiated kidney. The presence of the unirradiated contralateral kidney may effectively prevent the irradiated kidney from expressing any potential for repair and/or recovery of function. If this were true then the question would obviously arise, does the irradiated kidney retain some capacity for recovery? In order to answer this question, the contralateral unirradiated kidney was removed from pigs 26 weeks after the irradiation of the other kidney. The subsequent response of the irradiated kidney to nephrectomy was assessed in terms of the changes in renal size and haemodynamics, i.e. GFR and effective renal plasma flow (ERPF). (Auth.)

  9. In vivo genetic toxicity studies in Chinese hamsters fed irradiated or unirradiated foodstuffs

    International Nuclear Information System (INIS)

    Altmann, H.

    1982-01-01

    Two in vivo genetic toxicity studies were performed in Chinese hamsters fed irradiated or unirradiated diets of chicken, fish or dates in order to detect possible mutagenic effects caused by irradiating these foodstuffs. The tests selected for study were: 1. Chromosomal analysis of bone narrow cells and 2. DNA metabolism in spleen cells. Chicken, fish and dates were irradiated with doses of 7, 2.5 and 1 kGy respectively. These investigations were subsequently extended to include the effects of irradiated dried onions, pulses and cocoa beans on DNA metabolism in Chinese hamster spleen cells only. Dried onions were irradiated with doses of 0.15, 9 and 15 kGy, pulses with 10 kGy and cocoa beans with 3.2 to 5 kGy. In addition, a fumigated cocoa bean group was included. No significant differences in chromosomal aberration rate were detected between groups fed irradiated or unirradiated diets. Dried dates, whether irradiated or not, showed some evidence of genetic toxicity in their effect on DNA metabolism in the spleen cells of Chinese hamsters. Both date diets caused more strand breaks DNA than are usual for Chinese hamster spleen cells, but DNA repair was not adversely affected. Chicken, both irradiated and unirradiated, was found to enhance replicative DNA synthesis but had no effect on the DNA repair process. Irradiated fish, however, caused enhanced DNA synthesis compared to unirradiated fish, but also had no adverse effect on DNA repair. Irradiated white beans also enhanced DNA synthesis compared to controls whereas unirradiated samples inhibited synthesis. (orig./MG)

  10. PET/CT staging of T1-stage non-small cell lung cancer

    International Nuclear Information System (INIS)

    Salman, K. A.; Steinmann, C. H.; Von Schulthess, G. K.; Steinert, H. C.; Sukumar, V. P.

    2009-01-01

    Full text:Purpose: To evaluate the value of PET/CT in detecting occult metastases in patients with T 1 -stage non-small cell lung cancer (NSCLC). Method: Patients with proven NSCLC and T 1 -stage ( c m) were retrospectively analyzed. In all patients a whole-body 18 F-FDG PET/CT scan for initial staging was performed. The PET/CT findings were compared with all available clinical information, intra-operative findings and the histopathological results. Results: 95 patients (39 men, 56 women; age range, 19-85 years) were analyzed in our study. PET/CT in 68-95 patients correctly excluded mediastinal and distant metastases. In 17/95 patients (18%) mediastinal lymph-node metastases were proven (N 2 n=15; N 3 n=2). PET/CT correctly detected in 10/17 patients (58.8%) mediastinal nodal disease. The smallest mediastinal lymph-node metastasis detected by PET/CT had a size of 0.7 c m. In 7 patients PET/CT missed N 2 -stage. In three of these patients the SUVmax of the primary was c m. Only in one missed N 2 -stage metastasis was sized > 1.0 c m. The tumor histology (adenocarcinoma, squamous cell carcinoma) and location of the primary (central, periphery) did not influence the missed N 2 -stage by PET/CT. PET/CT diagnosed correctly N 3 -stage in 2 patients. 10/95 patients (10.5%) had distant metastases. PET/CT detected unknown M 1 -stage in 4/10 patients. In one patient a metastasis of the parietal pleura was missed by PET/CT. Conclusion: In our study, 28% patients with T 1 -stage NSCLC showed mediastinal or distant metastases. PET/CT was efficient in the detection of occult metastases. However, the sensitivity of PET/CT in mediastinal staging was only 64%.

  11. T1-weighted MRI as a substitute to CT for refocusing planning in MR-guided focused ultrasound

    International Nuclear Information System (INIS)

    Wintermark, Max; Sumer, Suna; Lau, Benison; Cupino, Alan; Tustison, Nicholas J; Demartini, Nicholas; Elias, William J; Kassell, Neal; Patrie, James T; Xin, Wenjun; Eames, Matt; Snell, John; Hananel, Arik; Aubry, Jean-Francois

    2014-01-01

    Precise focusing is essential for transcranial MRI-guided focused ultrasound (TcMRgFUS) to minimize collateral damage to non-diseased tissues and to achieve temperatures capable of inducing coagulative necrosis at acceptable power deposition levels. CT is usually used for this refocusing but requires a separate study (CT) ahead of the TcMRgFUS procedure. The goal of this study was to determine whether MRI using an appropriate sequence would be a viable alternative to CT for planning ultrasound refocusing in TcMRgFUS. We tested three MRI pulse sequences (3D T1 weighted 3D volume interpolated breath hold examination (VIBE), proton density weighted 3D sampling perfection with applications optimized contrasts using different flip angle evolution and 3D true fast imaging with steady state precision T2-weighted imaging) on patients who have already had a CT scan performed. We made detailed measurements of the calvarial structure based on the MRI data and compared those so-called ‘virtual CT’ to detailed measurements of the calvarial structure based on the CT data, used as a reference standard. We then loaded both standard and virtual CT in a TcMRgFUS device and compared the calculated phase correction values, as well as the temperature elevation in a phantom. A series of Bland–Altman measurement agreement analyses showed T1 3D VIBE as the optimal MRI sequence, with respect to minimizing the measurement discrepancy between the MRI derived total skull thickness measurement and the CT derived total skull thickness measurement (mean measurement discrepancy: 0.025; 95% CL (−0.22–0.27); p = 0.825). The T1-weighted sequence was also optimal in estimating skull CT density and skull layer thickness. The mean difference between the phase shifts calculated with the standard CT and the virtual CT reconstructed from the T1 dataset was 0.08 ± 1.2 rad on patients and 0.1 ± 0.9 rad on phantom. Compared to the real CT, the MR-based correction showed a 1 °C drop on the

  12. Correlation between CT grading and blood interleukin-6 in severe acute pancreatitis

    International Nuclear Information System (INIS)

    Yokohari, Kenji; Hirasawa, Hiroyuki; Oda, Shigeto; Shiga, Hidetoshi; Nakanishi, Kazuya; Nakamura, Masataka

    2003-01-01

    Computed tomography (CT) and an evaluating of the degree of severity in patients with severe acute pancreatitis (SAP) are required to decide the therapeutic strategy. We measured blood interleukin-6 (IL-6) in critically ill patients at our intensive care unit (ICU) in a daily clinical setting. To determine the significance of grading CT findings in SAP, we studied the correlation between CT grading and blood IL-6 in SAP patients on ICU admission. Among 31 SAP cases, 66 were CT grade III, 22 CT grade IV, and 3 cases CT grade V. Patients with a higher CT grade tended to have higher blood IL-6. Data also showed that mean blood IL-6 among SAP patients in stage 2 was significantly higher than that among those in stage 3 (p<0.05). From these results, we concluded that CT grading and IL-6 blood level have a different significance in the management of SAP patients. (author)

  13. T-staging of gastric cancer of air-filling multidetector-row CT: Comparison with hydro-multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kumano, Seishi, E-mail: kumano@radiol.med.kindai.ac.jp [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan); Okada, Masahiro; Shimono, Taro; Kuwabara, Masatomo; Yagyu, Yukinobu; Imaoka, Izumi; Ashikaga, Ryuichiro; Ishii, Kazunari; Murakami, Takamichi [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan)

    2012-11-15

    Purpose: The purpose of this study was to evaluate the accuracy of T-staging of gastric cancer by air-filling multidetector-row CT (air-MDCT) compared with water-filling MDCT (hydro-MDCT). Materials and methods: One hundred fifteen patients with histologically diagnosed gastric cancer were included in this study. Fifty-eight patients underwent air-MDCT, and the remaining 57 had hydro-MDCT using a 64-channel scanner. Based on the volumetric data of contrast-enhanced MDCT obtained about 75 s after intravenously injecting 525 mg iodine per kilogram patients weight (525 mgI/kg) nonionic contrast material at the rate of 2 ml/s, oblique coronal and oblique sagittal multi-planar reformatted images perpendicular to the stomach wall, including the tumor, were reconstructed on a workstation. Mural invasion of gastric cancer into the gastric wall, as visualized by CT, was classified according to the TNM classification, and the results of T-staging by MDCT were compared with those by pathologic analysis after surgery. Results: Correct assessment of T-staging by air-CT was achieved in 48 of 58 patients (83%), and that by hydro-MDCT was 49 of 57 patients (86%). The sensitivity, specificity, and accuracy of the technique in determining the invasion of serosa were 88%, 93%, and 91% for air-CT and 83%, 95%, and 91% for hydro-CT. There were no significant differences between hydro-MDCT and air-MDCT in sensitivity (P = 0.73), specificity (P = 0.71) and accuracy (P = 0.98). Conclusion: Air-MDCT is a very valuable tool in T-staging of gastric cancer as well as hydro-MDCT.

  14. Flair MR imaging in the Detection of subarachnoid hemorrhage : comparison with CT and T1-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Soo Hyun; Kim, Soo Youn; Lee, Ghi Jai; Shim, Jae Chan; Oh, Tae Kyung; Kim, Ho Kyun [College of Medicine, Jnje University, Seoul (Korea, Republic of)

    2000-03-01

    To compare the findings of fluid-attenuated inversion recovery (FLAIR) MR imaging in the detection of subarachnoid hemorrhage (SAH), with those of precontrast CT and T1-weighted MR imaging. In 13 patients (14 cases) with SAH, FLAIR MR images were retrospectively analyzed and compared with CT (10 patients, 11 cases) and T1-weighted MR images (9 cases). SAH was confirmed on the basis of high density along the subarachnoid space, as seen on precontrast CT, or lumbar puncture. MR imaging was performed on a 1.0T unit. FLAIR MR and CT images were obtained during the acute stage(less than 3 days after ictus) in 10 and 9 cases, respectively, during the subacute stage (4-14 days after ictus) in two cases and one, respectively, and during the chronic stage (more than 15 days after ictus) in two cases and one, respectively. CT was performed before FLAIR MR imaging, and the interval between CT and FLAIR ranged from 24 hours (6 cases) to 2-3 (2 cases) or 4-7 days (3 cases). In each study, the conspicuity of visualization of SAH was graded as excellent, good, fair, or negative at five locations (sylvian fissure, cortical sulci, anterior basal cistern, posterior basal cistern, and perimesencephalic cistern). In all cases, subarachnoid hemorrhages were demonstrated as high signal intensity areas on FLAIR images. The detection rates for SAH on CT and T1-weighted MR images were 100% (11/11) and 89% (8/9), respectively. FLAIR was superior to T1-weighted imaging in the detection of SAH at all sites except the anterior basal cistern (p less than 0.05) and superior to CT in the detection of SAH at the cortical sulci (p less than 0.05). On FLAIR MR images, subarachnoid hemorrhages at all stages are demonstrated as high signal intensity areas; the FLAIR MR sequence is thus considered useful in the detection of SAH. In particular FLAIR is more sensitive than CT for the detection of SAH in the cortical sulci. (author)

  15. Detection of irradiated spice in blend of irradiated and un-irradiated spices using thermoluminescence method

    International Nuclear Information System (INIS)

    Goto, Michiko; Yamazaki, Masao; Sekiguchi, Masayuki; Todoriki, Setsuko; Miyahara, Makoto

    2007-01-01

    Five blended spice sample were prepared by mixing irradiated and un-irradiated black pepper and paprika at different ratios. Blended black pepper containing 2%(w/w) of 5.4 kGy-irradiated black pepper showed no maximum at glow1. Irradiated black pepper samples, mixed to 5 or 10%(w/w), were identified as 'irradiated' or 'partially irradiated' or 'un-irradiated'. All samples with un-irradiated pepper up to 20%(w/w) were identified as irradiated'. In the case 5.0 kGy-irradiated paprika were mixed with un-irradiated paprika up to 5%(w/w), all samples were identified as irradiated'. The glow1 curves of samples, including irradiated paprika at 0.2%(w/w) or higher, exhibited a maximum between 150 and 250degC. The results suggest the existence of different critical mixing ratio for the detection of irradiation among each spices. Temperature range for integration of the TL glow intensity were compared between 70-400degC and approximate 150-250degC, and revealed that the latter temperature range was determined based on the measurement of TLD100. Although TL glow ratio in 150-250degC was lower than that of 70-400degC range, identification of irradiation was not affected. Treatment of un-irradiated black pepper and paprika with ultraviolet rays had no effect on the detection of irradiation. (author)

  16. Functional correlates of TSH, fT3 and fT4 in Alzheimer disease: a F-18 FDG PET/CT study.

    Science.gov (United States)

    Chiaravalloti, Agostino; Ursini, Francesco; Fiorentini, Alessandro; Barbagallo, Gaetano; Martorana, Alessandro; Koch, Giacomo; Tavolozza, Mario; Schillaci, Orazio

    2017-07-24

    The present study was aimed to investigate the relationships between thyroid stimulating hormone (TSH), freeT3 (fT3) and freeT4 (fT4) and brain glucose consumption as detectable by means of 2-deoxy-2-(F-18) fluoro-D-glucose (F-18 FDG) Positron Emission Tomography/Computed Tomography (PET/CT) in a selected population with Alzheimer disease (AD). We evaluated 87 subjects (37 males and 50 females, mean age 70 (±6) years old) with AD. All of them were subjected to TSH, fT3 and fT4 assay and to cerebrospinal fluid amyloid (Aβ1-42) and tau [phosphorylated-tau (p-tau) and total-tau (t-tau)] assay prior PET/CT examination. Values for TSH, fT3 and fT4 were in the normal range. The relationships were evaluated by means of statistical parametric mapping (SPM8) using age, sex, MMSE, scholarship and CSF values of amyloid and tau as covariates. We found a significant positive correlation between TSH values and cortical glucose consumption in a wide portion of the anterior cingulate cortex bilaterally (BA32) and left frontal lobe (BA25) (p FWE-corr <0.001; p FDRcorr <0.000; cluster extent 66950). No significant relationships were found between cortical F-18 FDG uptake and T3 and T4 serum levels. The results of our study suggest that a cortical dysfunction in anterior cingulate and frontal lobes may affect serum values of TSH in AD patients.

  17. LINC00673 rs11655237 C>T confers neuroblastoma susceptibility in Chinese population.

    Science.gov (United States)

    Zhang, Zhuorong; Chang, Yitian; Jia, Wei; Zhang, Jiao; Zhang, Ruizhong; Zhu, Jinhong; Yang, Tianyou; Xia, Huimin; Zou, Yan; He, Jing

    2018-02-28

    Neuroblastoma, which accounts for approximately 10% of all pediatric cancer-related deaths, has become a therapeutic challenge and global burden attributed to poor outcomes and mortality rates of its high-risk form. Previous genome-wide association studies (GWASs) identified the LINC00673 rs11655237 C>T polymorphism to be associated with the susceptibility of several malignant tumors. However, the association between this polymorphism and neuroblastoma susceptibility is not clear. We genotyped LINC00673 rs11655237 C>T in 393 neuroblastoma patients in comparison with 812 age-, gender-, and ethnicity-matched healthy controls. We found a significant association between the LINC00673 rs11655237 C>T polymorphism and neuroblastoma risk (TT compared with CC: adjusted odds ratio (OR) =1.80, 95% confidence interval (CI) =1.06-3.06, P =0.029; TT/CT compared with CC: adjusted OR =1.31, 95% CI =1.02-1.67, P =0.033; and T compared with C: adjusted OR =1.29, 95% CI =1.06-1.58, P =0.013). Furthermore, stratified analysis indicated that the rs11655237 T allele carriers were associated with increased neuroblastoma risk for patients with tumor originating from the adrenal gland (adjusted OR =1.51, 95% CI =1.06-2.14, P =0.021) and International Neuroblastoma Staging System (INSS) stage IV disease (adjusted OR =1.60, 95% CI =1.12-2.30, P =0.011). In conclusion, we verified that the LINC00673 rs11655237 C>T polymorphism might be associated with neuroblastoma susceptibility. Prospective studies with a large sample size and different ethnicities are needed to validate our findings. © 2018 The Author(s).

  18. FDG PET/CT and Mediastinal Nodal Metastasis Detection in Stage T1 Non-Small Cell Lung Cancer: Prognostic Implications

    International Nuclear Information System (INIS)

    Shin, Kyung Min; Lee, Kyung Soo; Shim, Young Mog; Kim, Jhin Gook; Kim, Byung Tae; Kwon, O Jung; Park, Keun Chil

    2008-01-01

    We aimed to compare the prognoses of patients with pathologically true negative (P-TN) N2 and PET/CT false negative (FN) results in stage T1 nonsmall cell lung cancer (NSCLC). Our institutional review board approved this retrospective study with a waiver of informed consent. The study included 184 patients (124 men and 60 women; mean age, 59 years) with stage T1 NSCLC who underwent an integrated PET/CT and surgery. After estimating the efficacy of PET/CT for detecting N2 disease, we determined and compared disease-free survival (DFS) rates in three groups (P-TN [n = 161], PET/CT FN [n = 12], and PET/CT true positive [TP, n = 11]) using the Kaplan-Meier analysis and log-rank test. Pathologic N2 disease was observed in 23 (12%) patients. PET/CT had an N2 disease detection sensitivity of 48% (11 of 23 patients), a specificity of 95% (153 of 161), and an accuracy of 89% (164 of 184). The 3-year DFS rate in the PET/CT FN group (31%, 95% confidence interval [CI]; 13.6-48.0%) was similar to that of the TP group (16%, 95% CI; 1.7-29.5%) (p = 0.649), but both groups had significantly shorter DFS rates than the P-TN group (77%, 95% CI; 72.0- 81.2%) (p < 0.001). The PET/CT shows a high specificity, but low sensitivity for detecting N2 disease in stage T1 NSCLC. Patients with PET/CT FN N2 disease have survival rates similar to PET/CT TP N2 disease patients, which are both substantially shorter than the survival rate of P-TN patients

  19. Whole-Body CT Screening--Should I or Shouldn't I Get One?

    Science.gov (United States)

    ... Procedures Medical Imaging Medical X-ray Imaging Whole-Body CT Screening--Should I or shouldn't I ... What are the risks and benefits of whole-body CT screening? Many people believe incorrectly that a ...

  20. SNP rs16906252C>T is an expression and methylation quantitative trait locus associated with an increased risk of developing MGMT-methylated colorectal cancer

    Science.gov (United States)

    Kuroiwa-Trzmielina, Joice; Wang, Fan; Rapkins, Robert W.; Ward, Robyn L.; Buchanan, Daniel D.; Win, Aung Ko; Clendenning, Mark; Rosty, Christophe; Southey, Melissa C.; Winship, Ingrid M.; Hopper, John L.; Jenkins, Mark A.; Olivier, Jake; Hawkins, Nicholas J.; Hitchins, Megan P.

    2016-01-01

    Purpose Methylation of the MGMT promoter is the major cause of O6-methylguanine methyltransferase deficiency in cancer and has been associated with the T variant of the promoter-enhancer SNP rs16906252C>T. We sought evidence for an association between the rs16906252C>T genotype and increased risk of developing a subtype of colorectal cancer (CRC) featuring MGMT methylation, mediated by genotype-dependent epigenetic silencing within normal tissues. Experimental design By applying a molecular pathological epidemiology case-control study design, associations between rs16906252C>T and risk for CRC overall, and CRC stratified by MGMT methylation status, were estimated using multinomial logistic regression in two independent retrospective series of CRC cases and controls. The test sample comprised 1054 CRC cases and 451 controls from Sydney, Australia. The validation sample comprised 612 CRC cases and 245 controls from the Australasian Colon Cancer Family Registry (ACCFR). To determine if rs16906252C>T was linked to a constitutively altered epigenetic state, quantitative allelic expression and methylation analyses were performed in normal tissues. Results An association between rs16906252C>T and increased risk of developing MGMT-methylated CRC in the Sydney sample was observed (OR 3.3; 95%CI=2.0–5.3; PT represents an expression and methylation quantitative trait locus. Conclusions We provide evidence that rs16906252C>T is associated with elevated risk for MGMT-methylated CRC, likely mediated by constitutive epigenetic repression of the T allele. PMID:27267851

  1. TNFalpha -308 C-->t and -863 C-->a polymorphisms and spermiogram characteristics.

    Science.gov (United States)

    Kurz, Christine; Bentz, Eva-Katrin; Denschlag, Dominik; Berner, Isabel; Keck, Christoph; Tempfer, Clemens B; Pietrowski, Detlef

    2008-01-01

    Genetic factors may play a role in male infertility. In a prospective case-control study, we assessed the allele and genotype frequencies of the TNFalpha -308 C-->T and -863 C-->A polymorphisms, detected by PCR of sperm DNA, of 577 Caucasian men recruited in an infertility clinic. Semen sampling was performed and spermiogram results were correlated to genetic data. The allele frequencies of the TNFalpha -308 C-->T and -863 C-->A polymorphisms were not significantly different between non-normozoospermic (n = 447) and normozoospermic (n = 130) men [758/894 (85%) and 134/894 (15%) vs. 213/269 (82%) and 43/260 (18%), p = 0.5, odds ratio (OR) 1.1, 95% confidence interval (CI) 0.74-1.76, and 749/894 (84%) and 145/894 (16%) vs. 212/260 (82%) and 48/260 (18%), p = 0.4, OR 1.2, 95% CI 0.78-1.76, respectively]. The genotype frequencies of the TNFalpha -308 C-->T and -863 C-->A polymorphisms were also not significantly different between non-normozoospermic and normozoospermic men. In addition, mutant alleles were not overrepresented in subgroups of men with the oligoasthenoteratozoospermia syndrome and asthenozoospermia. The TNFalpha -308 C-->T and -863 C-->A polymorphisms are not associated with spermiogram characteristics and do not represent molecular markers for genetic susceptibility to male infertility. Copyright 2008 S. Karger AG, Basel.

  2. Dermatofibrosarcoma protuberans. CT findings with pathologic correlation in 6 cases

    Energy Technology Data Exchange (ETDEWEB)

    Miyakawa, E. [Dept. of Radiology, Teikyo Univ. School of Medicine, Ichihara Hospital, Chiba (Japan); Fujimoto, H. [Dept. of Radiology, Numazu City Hospital, Teikyo Univ. School of Medicine, Ichihara Hospital (Japan); Miyakawa, K. [Dept. of Diagnostic Radiology, Teikyo Univ. School of Medicine, Ichihara Hospital, Chiba (Japan); Nemoto, K. [Dept. of Radiology, Haibara General Hospital, Teikyo Univ. School of Medicine, Ichihara Hospital, Chiba (Japan); Kozawa, K. [Dept. of Surgery, Teikyo Univ. School of Medicine, Ichihara Hospital, Chiba (Japan); Sugano, I. [Dept. of Pathology, Teikyo Univ. School of Medicine, Ichihara Hospital, Chiba (Japan); Odani, Y. [Dept. of Radiology, Teikyo Univ. School of Medicine, Ichihara Hospital, Chiba (Japan); Hirata, T. [Dept. of Radiology, Teikyo Univ. School of Medicine, Ichihara Hospital, Chiba (Japan); Ogata, H. [Dept. of Radiology, Teikyo Univ. School of Medicine, Ichihara Hospital, Chiba (Japan); Ohno, T. [Dept. of Orthopedics, Teikyo Univ. School of Medicine, Ichihara Hospital, Chiba (Japan)

    1995-05-01

    CT and pathologic specimens of 6 patients with dermatofibrosarcoma protuberans (5 in the trunk and 1 in the leg) were retrospectively reviewed. CT clearly defined the tumors in the dermis and subcutaneous tissue with a characteristic, if not pathognomonic, protrusion. On postcontrast CT, 3 tumors showed marginal enhancement and central low density, while the others showed homogeneous enhancement. Pathologically, the marginal enhancement on CT corresponded to fibrosarcomatous changes, and the central low density to necrosis. The tumors with homogeneous enhancement had no sarcomatous changes. CT allows detection and precise anatomic localization of dermatofibrosarcoma protuberans. Marginal enhancement with central low density on CT may suggest a relatively poor prognosis. (orig.).

  3. Dermatofibrosarcoma protuberans. CT findings with pathologic correlation in 6 cases

    International Nuclear Information System (INIS)

    Miyakawa, E.; Fujimoto, H.; Miyakawa, K.; Nemoto, K.; Kozawa, K.; Sugano, I.; Odani, Y.; Hirata, T.; Ogata, H.; Ohno, T.

    1995-01-01

    CT and pathologic specimens of 6 patients with dermatofibrosarcoma protuberans (5 in the trunk and 1 in the leg) were retrospectively reviewed. CT clearly defined the tumors in the dermis and subcutaneous tissue with a characteristic, if not pathognomonic, protrusion. On postcontrast CT, 3 tumors showed marginal enhancement and central low density, while the others showed homogeneous enhancement. Pathologically, the marginal enhancement on CT corresponded to fibrosarcomatous changes, and the central low density to necrosis. The tumors with homogeneous enhancement had no sarcomatous changes. CT allows detection and precise anatomic localization of dermatofibrosarcoma protuberans. Marginal enhancement with central low density on CT may suggest a relatively poor prognosis. (orig.)

  4. Association of interleukin-1β -511 C/T polymorphism with tobacco-associated cancer in northeast India: a study on oral and gastric cancer.

    Science.gov (United States)

    Lakhanpal, Meena; Yadav, Dhirendra Singh; Devi, Thoudam Regina; Singh, Laishram Chandreshwor; Singh, Khangembam Jitenkumar; Latha, Santhi P; Chauhan, Pradeep Singh; Verma, Yogesh; Zomavia, Eric; Sharma, Jagannath; Chandra Kataki, Amal; Saxena, Sunita; Kapur, Sujala

    2014-01-01

    The IL-1β -511 C/T polymorphism is associated with increased IL-1 production and with increased risk of developing cancers. In this study, 251 patients (125 with gastric cancer [GC] and 126 with oral cancer [OC]) and 207 normal controls from northeast (NE) India were genotyped for the IL-1β -511 C/T polymorphism by PCR-restriction fragment length polymorphism (RFLP) and sequencing. Analysis of results showed betel-quid chewing to be a major risk factor (OR = 2.01, 95% CI = 1.05-3.87; P = 0.035) for OC. Inheritance of the IL-1β -511 CT or TT resulted in a 2.6- to 3.05-fold increase in the risk of developing OC relative to that of participants who possessed the reference genotype (OR = 2.57, 95% CI = 1.06-6.22; P = 0.036 and OR = 3.05, 95% CI = 1.22-7.63; P = 0.017), after adjusting for potential confounders. The dominant genetic model also confirmed the presence of the T allele as a significant risk factor for OC (OR = 2.72, 95% CI = 1.15-6.42; P = 0.02). In GC, interaction of the CT genotype with tobacco and betel-quid chewing habits conferred a significant 78% and 89% reduced risk of cancer, respectively. In conclusion, for the NE Indian population, the IL-1β -511 CC and CT genotypes were significantly associated with increased risk of OC. However, the interaction of the CT genotype with risk habits may play a preventive role for GC but not for OC. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Diagnostic performance of 64-section CT using CT gastrography in preoperative T staging of gastric cancer according to 7th edition of AJCC cancer staging manual

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Shin, Sang Soo; Heo, Suk Hee; Lim, Hyo Soon; Jeong, Yong Yeon; Kang, Heoung Keun; Choi, Yoo Duk; Park, Young Kyu; Park, Chang Hwan

    2012-01-01

    To evaluate the accuracy of 64-section multidetector CT with CT gastrography for determining the depth of mural invasion in patients with gastric cancer according to the 7th edition of the AJCC cancer staging manual. A total of 127 patients with gastric cancer and who had undergone both esophago-gastro-duodenoscopy and 64-section CT were included in this study. Two radiologists independently reviewed the preoperative CT images with respect to the detectability and T-staging of the gastric cancers. The sensitivity, specificity, accuracy and overall accuracy of each reviewer for the T staging of gastric cancer were calculated. Overall, gastric cancer was detected in 123 (96.9%) of the 127 cancers on the CT images. Reviewer 1 correctly staged 98 gastric cancers, and reviewer 2 correctly classified 105 gastric cancers. The overall diagnostic accuracy of the T staging was 77.2% (98/127) for reviewer 1 and 82.7% (105/127) for reviewer 2. 64-section CT using CT gastrography showed a reasonable diagnostic performance for determining the T staging in patients with gastric cancer according to the 7th edition of the AJCC cancer staging manual. (orig.)

  6. Safety analysis report for packaging: the ORNL HFIR unirradiated fuel element shipping container

    International Nuclear Information System (INIS)

    Evans, J.H.; Boulet, J.A.M.; Eversole, R.E.

    1977-11-01

    The ORNL HFIR unirradiated fuel element shipping container was designed and fabricated at the Oak Ridge National Laboratory for the transport of HFIR unirradiated fuel elements. The container was evaluated analytically and experimentally to determine its compliance with the applicable regulations governing containers in which radioactive and fissile materials are transported, and the evaluation is the subject of this report. Computational and test procedures were used to determine the structural integrity and thermal behavior of the cask relative to the general standards for normal conditions of transport and the standards for the hypothetical accident conditions. The results of the evaluation demonstrate that the container is in compliance with the applicable regulations

  7. Muscular involvement by malignant lymphoma: CT and MR findings

    International Nuclear Information System (INIS)

    Kim, Baek Hyun

    2000-01-01

    To investigate the CT and MR findings of muscular involvement by malignant lymphoma. Thirteen patients with biopsy-proved muscular involvement by malignant lymphoma were included in this study. Two patients were primary muscle lymphoma and 11 patients were muscle lymphoma by secondary involvement of malignant lymphoma. CT of 10 patients (6 pre-contrast CT and 9 postcontrast CT) and MRI of 6 patients (all with pre a nd post-contrast studies) were retrospectively analyzed. In the majority of patients (84.6%, 11/13), the appearance of muscular involvement was the diffuse enlargement of several muscles as like as a group. The muscles involved by malignant lymphoma showed iso-attenuation (5/6) and homogeneity (6/6) on pre-contrast CT scan, and high attenuation (5/9) or iso-attenuation (4/9) and homogeneity (7/9) on post-contrast CT scan. The signal intensity of involved muscle showed slightly hyper- (4/6) or iso-intense (2/6) and homogeneous (6/6) on T1-weighted images, and hyper-intense (6/6) and homogeneous (4/6) on T2- and Gadolinium-enhanced T1-weighted images. Adjacent bone change was demonstrated in 69.2% (9/13), subcutaneous fat change in 61.5% (8/13), and neurovascular encasement within involved muscle in 53.8% (7/13). The CT and MR findings of muscular involvement by malignant lymphoma were diffuse enlargement of several muscles with homogeneous attenuation or signal intensity, and frequent changes in adjacent bones and subcutaneous fat, or neurovascular encasement. (author)

  8. CT and MRI diagnosis of acute hepatic injury

    International Nuclear Information System (INIS)

    Wang Rengui; Fumio Yamamoto; Pu Yonglin; Gao Yujie.

    1997-01-01

    To evaluate and compare MR and CT in diagnosis of acute traumatic hepatic laceration, ten patients with acute hepatic rupture underwent CT scan and/or MRI in the first 24 hours after injury. The injury was graded as mild ( 50% of one lobe). In the first 24 hours after injury, 33.3% (3/9) and 28.6%(2/7) of the hepatic injury demonstrated isodensity and isointensity on plain CT scan and T 1 -weighted images. All the lesions (100%) were clearly identified as marked hyperintensity on T 2 -weighted images. On T 2 WI, T 1 WI and non-contrast CT, 100%, 57.1% and 55.6% of the acute hepatic injuries could be graded respectively. Delayed complications occurred in four patients with deep hepatic injury about 1 to 3 weeks after injury. T 2 -weighted MR imaging is more sensitive and useful for detection of the type and severity of acute hepatic rupture. Follow-up MRI or CT within the first few weeks after injury is needed in patients with deep hepatic injury for detection of delayed complications

  9. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  10. Whole-body MRI at 1.5 T and 3 T compared with FDG-PET-CT for the detection of tumour recurrence in patients with colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, G.P.; Baur-Melnyk, A.; Becker, C.R.; Reiser, M.F.; Hermann, K.A. [Ludwig Maximilian University Munich, Department of Clinical Radiology, University Hospitals Grosshadern, Munich (Germany); Haug, A.; Tiling, R. [University Hospitals Grosshadern, Ludwig Maximilian University Munich, Department of Nuclear Medicine, Munich (Germany); Utzschneider, S. [University Hospitals Grosshadern, Ludwig Maximilian University Munich, Department of Orthopedics, Munich (Germany)

    2009-06-15

    The purpose of this study was to assess the diagnostic accuracy of whole-body MRI (WB-MRI) at 1.5 T or 3 T compared with FDG-PET-CT in the follow-up of patients suffering from colorectal cancer. In a retrospective study, 24 patients with a history of colorectal cancer and suspected tumour recurrence underwent FDG-PET-CT and WB-MRI with the use of parallel imaging (PAT) for follow-up. High resolution coronal T1w-TSE and STIR sequences at four body levels, HASTE imaging of the lungs, contrast-enhanced T1w- and T2w-TSE sequences of the liver, brain, abdomen and pelvis were performed, using WB-MRI at either 1.5 T (n = 14) or 3 T (n = 10). Presence of local recurrent tumour, lymph node involvement and distant metastatic disease was confirmed using radiological follow-up within at least 5 months as a standard of reference. Seventy seven malignant foci in 17 of 24 patients (71%) were detected with both WB-MRI and PET-CT. Both investigations concordantly revealed two local recurrent tumours. PET-CT detected significantly more lymph node metastases (sensitivity 93%, n = 27/29) than WB-MRI (sensitivity 63%, n = 18/29). PET-CT and WB-MRI achieved a similar sensitivity for the detection of organ metastases with 80% and 78%, respectively (37/46 and 36/46). WB-MRI detected brain metastases in one patient. One false-positive local tumour recurrence was indicated by PET-CT. Overall diagnostic accuracy for PET-CT was 91% (sensitivity 86%, specificity 96%) and 83% for WB-MRI (sensitivity 72%, specificity 93%), respectively. Examination time for WB-MRI at 1.5 T and 3 T was 52 min and 43 min, respectively; examination time for PET-CT was 103 min. Initial results suggest that differences in accuracy for local and distant metastases detection using FDG-PET-CT and WB-MRI for integrated screening of tumour recurrence in colorectal cancer depend on the location of the malignant focus. Our results show that nodal disease is better detected using PET-CT, whereas organ disease is depicted

  11. Association of β-fibrinogen promoter gene polymorphism (−148C/T), hyperfibrinogenemia and ischemic stroke in young adult patients

    OpenAIRE

    Imran, Imran; Lamsudin, Rusdi; Idjradinata, Ponpon; Achmad, Tri Hanggono; Maskoen, Amelani; Wibowo, Samekto; Harapan, Harapan

    2015-01-01

    Background: Single nucleotide polymorphism (SNP) −148C/T which is located in β-fibrinogen gene (FGB) promoter has correlation with fibrinogen levels; however, the association of SNP −148C/T and ischemic stroke in young adult patients is contradictory. Aim: To determine the association of SNP −148C/T in FGB promoter with plasma fibrinogen levels and ischemic stroke in young adults. Subjects and methods: In this case-control study, SNP −148C/T among 107 ischemic stroke patients and 94 con...

  12. Association of Lactase 13910 C/T polymorphism with bone mineral ...

    Indian Academy of Sciences (India)

    Navya

    2017-03-24

    Mar 24, 2017 ... investigate the possible race-specific effect of LCT-13910 C/T polymorphism on .... analyses were performed using STATA version 11.0 (Stata Corporation, College Station, TX, USA). .... All authors have no conflicts of interest.

  13. Rescue Effects: Irradiated Cells Helped by Unirradiated Bystander Cells

    Science.gov (United States)

    Lam, R. K. K.; Fung, Y. K.; Han, W.; Yu, K. N.

    2015-01-01

    The rescue effect describes the phenomenon where irradiated cells or organisms derive benefits from the feedback signals sent from the bystander unirradiated cells or organisms. An example of the benefit is the mitigation of radiation-induced DNA damages in the irradiated cells. The rescue effect can compromise the efficacy of radioimmunotherapy (RIT) (and actually all radiotherapy). In this paper, the discovery and subsequent confirmation studies on the rescue effect were reviewed. The mechanisms and the chemical messengers responsible for the rescue effect studied to date were summarized. The rescue effect between irradiated and bystander unirradiated zebrafish embryos in vivo sharing the same medium was also described. In the discussion section, the mechanism proposed for the rescue effect involving activation of the nuclear factor κB (NF-κB) pathway was scrutinized. This mechanism could explain the promotion of cellular survival and correct repair of DNA damage, dependence on cyclic adenosine monophosphate (cAMP) and modulation of intracellular reactive oxygen species (ROS) level in irradiated cells. Exploitation of the NF-κB pathway to improve the effectiveness of RIT was proposed. Finally, the possibility of using zebrafish embryos as the model to study the efficacy of RIT in treating solid tumors was also discussed. PMID:25625514

  14. A highway accident involving unirradiated nuclear fuel in Springfield, Massachusetts, on December 16, 1991

    International Nuclear Information System (INIS)

    Carlson, R.W.; Fischer, L.E.

    1992-06-01

    In the early morning of Dec. 16, 1991, a severe accident occurred when a passenger vehicle traveling in the wrong direction collided with a tractor trailer carrying 24 unirradiated nuclear fuel assemblies in 12 containers on Interstate I-91 in Springfield, Massachusetts. The purpose of this report is to document the mechanical circumstances of the severe accident, confirm the nature and quantity of the radioactive materials involved, and assess the physical environment to which the containers were exposed and the response of the containers and their contents. The report consists of five major sections. The first section describes the circumstances and conditions of the accident and the finding of facts. The second describes the containers, the unirradiated nuclear fuel assemblies, and the tie down arrangement used for the trailer. The third describes the damage sustained during the accident to the tractor, trailer, containers, and unirradiated nuclear fuel assemblies. The fourth evaluates the accident environment and its effects on the containers and their contents. The final section gives conclusions derived from the analysis and fact finding investigation. During this severe accident, only minor injuries occurred, and at no time was the public health and safety at risk

  15. Stress corrosion crack growth in unirradiated zircaloy

    International Nuclear Information System (INIS)

    Pettersson, K.

    1978-10-01

    Experimental techniques suitable for the determination of stress corrosion crack growth rates in irradiated Zircaloy tube have been developed. The techniques have been tested on unirradiated. Zircaloy and it was found that the results were in good agreement with the results of other investigations. Some of the results were obtained at very low stress intensities and the crack growth rates observed, gave no indication of the existance of a K sub(ISCC) for iodine induced stress corrosion cracking in Zircaloy. This is of importance both for fuel rod behavior after a power ramp and for long term storage of spent Zircaloy-clad fuel. (author)

  16. Clinical significance of changes of serum contents of IL-8, CT, BGF and T in elderly men with osteoporosis

    International Nuclear Information System (INIS)

    Zhou Jian

    2011-01-01

    Objective: To study the clinical significance of changes of serum contents of IL-8 calcitonin (CT) bone glaprotein (BGF) and testosterone (T) in elderly men with osteoporosis. Methods: The serum IL-8, CT, BGP and T levels were determined with RIA in 33 elderly men with osteoporosis and 35 controls. Results: The serum levels of IL-8 were significantly higher, but levels of CT, BGP and T were significantly lower in the elderly men with osteoporosis than those in controls (P<0.01). There were significantly negative relationship between the serum levels of IL-8 and serum levels of CT, BGP and T (r = -0.4712, -0.5014, -0.4915, P<0.05). Conclusion: The changes of IL-8, CT, BGP and T levels correctly reflected increase of bone absorption with less osteogenesis, which was characteristic in osteoporosis. (authors)

  17. CT and MRI findings of chorea associated with nonketotic hyperglycemia

    International Nuclear Information System (INIS)

    Hu Dongjin; Zhang Weidong; Wu Dingquan; Meng Lishi; Chen Jian

    2008-01-01

    Objective: To explore the imaging diagnosis of chorea associated with nonketotic hyperglycemia by describing its CT and MR findings and correlating those findings with the clinical manifestations. Methods: The imaging findings and clinical data from 6 patients with chorea associated with nonketotic hyperglycemia were retrospectively analyzed. All 6 patients had unenhanced CT scans, 1 also had MR imaging examination. Three of 6 patients had follow-up CT scans and 1 of 3 patients had follow-up MR imaging studies. Results: CT studies of all 6 patients showed unilateral or bilateral hyperdense striatum. The putamen was involved in all 6 patients, the caudate nucleus or lateral portion of the globus pallidus were involved in 5 of all 6 patients. All 3 follow-up CT studies depicted a decreased or resolved hyperdensity of the abnormal striatum. T 1 -weighted MR images in 1 patient showed the hyperintense lesions of bilateral lentiform nuclei, T 2 -weighted MR images of the patient showed the hypointense lesions of the corresponding lentiform nuclei, and its follow-up MR images depicted invariable signal intensity of T 1 -weighted and T 2 -weighted images. In all patients, the chorea resolved within 2 to 6 days after treatment of the hyperglycemia. Conclusion: The characteristic imaging findings of chorea associated with nonketotic hyperglycemia can suggest an accurate diagnosis. (authors)

  18. Unirradiated cladding rip-propagation tests

    International Nuclear Information System (INIS)

    Hu, W.L.; Hunter, C.W.

    1981-04-01

    The size of cladding rips which develop when a fuel pin fails can affect the subassembly cooling and determine how rapidly fuel escapes from the pin. The object of the Cladding Rip Propagation Test (CRPT) was to quantify the failure development of cladding so that a more realistic fuel pin failure modeling may be performed. The test results for unirradiated 20% CS 316 stainless steel cladding show significantly different rip propagation behavior at different temperatures. At room temperature, the rip growth is stable as the rip extension increases monotonically with the applied deformation. At 500 0 C, the rip propagation becomes unstable after a short period of stable rip propagation. The rapid propagation rate is approximately 200 m/s, and the critical rip length is 9 mm. At test temperatures above 850 0 C, the cladding exhibits very high failure resistances, and failure occurs by multiple cracking at high cladding deformation. 13 figures

  19. Pediatric cT: Implementation of ASIR for Substantial Radiation Dose Reduction While Maintaining Pre-ASIR Image Noise1

    Science.gov (United States)

    Brady, Samuel L.; Moore, Bria M.; Yee, Brian S.; Kaufman, Robert A.

    2015-01-01

    Purpose To determine a comprehensive method for the implementation of adaptive statistical iterative reconstruction (ASIR) for maximal radiation dose reduction in pediatric computed tomography (CT) without changing the magnitude of noise in the reconstructed image or the contrast-to-noise ratio (CNR) in the patient. Materials and Methods The institutional review board waived the need to obtain informed consent for this HIPAA-compliant quality analysis. Chest and abdominopelvic CT images obtained before ASIR implementation (183 patient examinations; mean patient age, 8.8 years ± 6.2 [standard deviation]; range, 1 month to 27 years) were analyzed for image noise and CNR. These measurements were used in conjunction with noise models derived from anthropomorphic phantoms to establish new beam current–modulated CT parameters to implement 40% ASIR at 120 and 100 kVp without changing noise texture or magnitude. Image noise was assessed in images obtained after ASIR implementation (492 patient examinations; mean patient age, 7.6 years ± 5.4; range, 2 months to 28 years) the same way it was assessed in the pre-ASIR analysis. Dose reduction was determined by comparing size-specific dose estimates in the pre- and post-ASIR patient cohorts. Data were analyzed with paired t tests. Results With 40% ASIR implementation, the average relative dose reduction for chest CT was 39% (2.7/4.4 mGy), with a maximum reduction of 72% (5.3/18.8 mGy). The average relative dose reduction for abdominopelvic CT was 29% (4.8/6.8 mGy), with a maximum reduction of 64% (7.6/20.9 mGy). Beam current modulation was unnecessary for patients weighing 40 kg or less. The difference between 0% and 40% ASIR noise magnitude was less than 1 HU, with statistically nonsignificant increases in patient CNR at 100 kVp of 8% (15.3/14.2; P = .41) for chest CT and 13% (7.8/6.8; P = .40) for abdominopelvic CT. Conclusion Radiation dose reduction at pediatric CT was achieved when 40% ASIR was implemented as a dose

  20. Whole body X-ray CT scanner SCT-3000T series

    International Nuclear Information System (INIS)

    Saida, Teruhiko; Takemura, Kunihiko; Suzuki, Satoru; Sato, Yukio; Kawamoto, Yasushi; Goto, Mitsuhiro; Mishina, Yukio

    1989-01-01

    The whole body CT scanner, SCT-3000T series which improve the patient through-put and the diagnostic capability, has been developed. In the SCT-3000T series CT scanners, the great reduction of the reconstruction time and the scan cycle time has been achieved by developing the special purpose hardwares for image reconstruction such as the fast front end processor, the intelligent buffer memory. In case of the SCT-3000TX routine conditions of operation, including 3.0 sec scan, table increment, image reconstruction and image filing, the scan cycle time is about 9 seconds which is the shortest value among the competitive models. Furthermore, the higher diagnostic capability has been provided with the system, by adopting the 1024 x 1024 display matrices, and by developing the diagnostic softwares such as 3-D display program, arbitrary curved plane MPR program, r-CBF measurement program and etc. (author)

  1. Is There an Additional Value of 11C-Choline PET-CT to T2-weighted MRI Images in the Localization of Intraprostatic Tumor Nodules?

    International Nuclear Information System (INIS)

    Van den Bergh, Laura; Koole, Michel; Isebaert, Sofie; Joniau, Steven; Deroose, Christophe M.; Oyen, Raymond; Lerut, Evelyne; Budiharto, Tom; Mottaghy, Felix; Bormans, Guy; Van Poppel, Hendrik; Haustermans, Karin

    2012-01-01

    Purpose: To investigate the additional value of 11 C-choline positron emission tomography (PET)-computed tomography (CT) to T2-weighted (T2w) magnetic resonance imaging (MRI) for localization of intraprostatic tumor nodules. Methods and Materials: Forty-nine prostate cancer patients underwent T2w MRI and 11 C-choline PET-CT before radical prostatectomy and extended lymphadenectomy. Tumor regions were outlined on the whole-mount histopathology sections and on the T2w MR images. Tumor localization was recorded in the basal, middle, and apical part of the prostate by means of an octant grid. To analyze 11 C-choline PET-CT images, the same grid was used to calculate the standardized uptake values (SUV) per octant, after rigid registration with the T2w MR images for anatomic reference. Results: In total, 1,176 octants were analyzed. Sensitivity, specificity, and accuracy of T2w MRI were 33.5%, 94.6%, and 70.2%, respectively. For 11 C-choline PET-CT, the mean SUV max of malignant octants was significantly higher than the mean SUV max of benign octants (3.69 ± 1.29 vs. 3.06 ± 0.97, p mean values (2.39 ± 0.77 vs. 1.94 ± 0.61, p mean and absolute tumor volume (Spearman r = 0.3003, p = 0.0362). No correlation was found between SUVs and prostate-specific antigen, T-stage or Gleason score. The highest accuracy (61.1%) was obtained with a SUV max cutoff of 2.70, resulting in a sensitivity of 77.4% and a specificity of 44.9%. When both modalities were combined (PET-CT or MRI positive), sensitivity levels increased as a function of SUV max but at the cost of specificity. When only considering suspect octants on 11 C-choline PET-CT (SUV max ≥ 2.70) and T2w MRI, 84.7% of these segments were in agreement with the gold standard, compared with 80.5% for T2w MRI alone. Conclusions: The additional value of 11 C-choline PET-CT next to T2w MRI in detecting tumor nodules within the prostate is limited.

  2. Use of normoxic polymer gel dosimeters for measuring diagnostic doses on CT scanners

    International Nuclear Information System (INIS)

    Hill, B; Venning, A J; Baldock, C

    2004-01-01

    X-ray CT has been used to evaluate polymer gel dosimeters for dose response in the therapeutic dose range. This method of polymer gel dosimeter evaluation has been shown to be useful for instance in the comparison of complex sterotactic field distributions with treatment plans. Image averaging and subtraction techniques are used for noise reduction in polymer gel dosimeters resulting in the delivery of several CT slices across the polymer gel dosimeters. It was a logical progression to evaluate normoxic polymer gel dosimeters with optimized CT scanning protocols. During these investigations it was found that unirradiated regions in irradiated normoxic polymer gel dosimetry phantoms polymerised possibly as a result of the evaluation using CT. This prompted an investigation of the CT diagnostic dose response of the normoxic polymer gel dosimeter in order to determine the dose contribution when evaluated using a CT scanner. Having established that there was an effect on the normoxic polymer gel dosimeter when evaluating with a CT scanner the suitability of these gels in the determination of CT diagnostic dose measurement was further investigated

  3. T2 mapping of CT remodelling patterns in interstitial lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Buzan, Maria T.A. [Iuliu Hatieganu University of Medicine and Pharmacy, Department of Pneumology, Cluj-Napoca (Romania); Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Eichinger, Monika; Heussel, Claus Peter [Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Kreuter, Michael; Herth, Felix J. [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Thoraxklinik at Heidelberg University Hospital, Department of Pneumology, Center for Rare and Interstitial Lung Diseases, Heidelberg (Germany); Kauczor, Hans-Ulrich [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Warth, Arne [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); University Hospital Heidelberg, Institute for Pathology, Heidelberg (Germany); Pop, Carmen Monica [Iuliu Hatieganu University of Medicine and Pharmacy, Department of Pneumology, Cluj-Napoca (Romania); Dinkel, Julien [Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Comprehensive Pneumology Center Munich (CPC-M), German Center for Lung Research (DZL), Munich (Germany); Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-11-15

    To evaluate lung T2 mapping for quantitative characterization and differentiation of ground-glass opacity (GGO), reticulation (RE) and honeycombing (HC) in usual interstitial pneumonia (UIP) and non-specific interstitial pneumonia (NSIP). Twelve patients with stable UIP or NSIP underwent thin-section multislice CT and 1.5-T MRI of the lung. A total of 188 regions were classified at CT into normal (n = 29) and pathological areas, including GGO (n = 48), RE (n = 60) and HC (n = 51) predominant lesions. Entire lung T2 maps based on multi-echo single shot TSE sequence (TE: 20, 40, 79, 140, 179 ms) were generated from each subject with breath-holds at end-expiration and ECG-triggering. The median T2 relaxation of GGO was 67 ms (range 60-72 ms). RE predominant lesions had a median relaxation of 74 ms (range 69-79 ms), while for HC pattern this was 79 ms (range 74-89 ms). The median T2 relaxation for normal lung areas was 41 ms (ranged 38-49 ms), and showed significant difference to pathological areas (p < 0.001). A statistical difference was found between the T2 relaxation of GGO, RE and HC (p < 0.05). The proposed method provides quantitative information for pattern differentiation, potentially allowing for monitoring of progression and response to treatment, in interstitial lung disease. (orig.)

  4. T2 mapping of CT remodelling patterns in interstitial lung disease

    International Nuclear Information System (INIS)

    Buzan, Maria T.A.; Eichinger, Monika; Heussel, Claus Peter; Kreuter, Michael; Herth, Felix J.; Kauczor, Hans-Ulrich; Warth, Arne; Pop, Carmen Monica; Dinkel, Julien

    2015-01-01

    To evaluate lung T2 mapping for quantitative characterization and differentiation of ground-glass opacity (GGO), reticulation (RE) and honeycombing (HC) in usual interstitial pneumonia (UIP) and non-specific interstitial pneumonia (NSIP). Twelve patients with stable UIP or NSIP underwent thin-section multislice CT and 1.5-T MRI of the lung. A total of 188 regions were classified at CT into normal (n = 29) and pathological areas, including GGO (n = 48), RE (n = 60) and HC (n = 51) predominant lesions. Entire lung T2 maps based on multi-echo single shot TSE sequence (TE: 20, 40, 79, 140, 179 ms) were generated from each subject with breath-holds at end-expiration and ECG-triggering. The median T2 relaxation of GGO was 67 ms (range 60-72 ms). RE predominant lesions had a median relaxation of 74 ms (range 69-79 ms), while for HC pattern this was 79 ms (range 74-89 ms). The median T2 relaxation for normal lung areas was 41 ms (ranged 38-49 ms), and showed significant difference to pathological areas (p < 0.001). A statistical difference was found between the T2 relaxation of GGO, RE and HC (p < 0.05). The proposed method provides quantitative information for pattern differentiation, potentially allowing for monitoring of progression and response to treatment, in interstitial lung disease. (orig.)

  5. High Temperature Tensile Properties of Unirradiated and Neutron Irradiated 20 Cr-35 Ni Austenitic Steel

    Energy Technology Data Exchange (ETDEWEB)

    Roy, R B; Solly, B

    1966-12-15

    The tensile properties of an unirradiated and neutron irradiated (at 40 deg C) 20 % Cr, 35 % Ni austenitic steel have been studied at 650 deg C, 750 deg C and 820 deg C. The tensile elongation and mode of fracture (transgranular) of unirradiated specimens tested at room temperature and 650 deg C are almost identical. At 750 deg C and 820 deg C the elongation decreases considerably and a large part of the total elongation is non-uniform. Furthermore, the mode of fracture at these temperatures is intergranular and microscopic evidence suggests that fracture is caused by formation and linkup of grain boundary cavities. YS and UTS decrease monotonically with temperature. Irradiated specimens show a further decrease in ductility and an increase in the tendency to grain boundary cracking. Irradiation has no significant effect on the YS, but the UTS are reduced. The embrittlement of the irradiated specimens is attributed to the presence of He and Li atoms produced during irradiation and the possible mechanisms are discussed. Prolonged annealing of irradiated and unirradiated specimens at 650 deg C appears to have no significant effect on tensile properties.

  6. CD14-159C/T polymorphism in the development of delayed skin hypersensitivity to tuberculin.

    Directory of Open Access Journals (Sweden)

    Magdalena Druszczynska

    Full Text Available The skin tuberculin test (TST, an example of a delayed-type hypersensitivity (DTH reaction, is based on measuring the extent of skin induration to mycobacterial tuberculin (PPD. Little is known about the genetic basis of TST reactivity, widely used for diagnosing TB infection. The study investigated the relationship of the single base change polymorphic variants in CD14 gene (CD14(-159C/T with the development of DTH to PPD in BCG-vaccinated Polish Caucasian individuals. We found persistent lack of TST reactivity in about 40% of healthy subjects despite receiving more than one dose of BCG. The TST size was negatively correlated with the number of BCG inoculations. The distribution of C/T genotype was significantly more frequent among TST-negative compared with TST-positive individuals. The concentration of serum sCD14 was positively associated with mCD14 expression, but not with the TST status or CD14(-159C/T polymorphism. A significant increase in mCD14 expression and serum sCD14 levels was found in TB group. We hypothesize that CD14(-159C/T polymorphic variants might be one of genetic components in the response to attenuated M. bovis BCG bacilli.

  7. Utility of interim and end-of-treatment PET/CT in peripheral T-cell lymphomas

    DEFF Research Database (Denmark)

    El-Galaly, Tarec Christoffer; Pedersen, Martin Bjerregård; Hutchings, Martin

    2015-01-01

    According to the updated guidelines for imaging in lymphoma, 18F-FDG positron emission tomography/computed tomography (PET/CT) is recommended for staging and evaluation of treatment response in FDG-avid lymphomas. The purpose of the study was to evaluate the utility of PET/CT in nodal peripheral T....../CT. Medical records were reviewed for baseline clinical and follow-up information. Staging, interim (I-PET), and end-of-treatment PET/CT (E-PET) studies were centrally reviewed, and reported using the Deauville 5-point score (DS). A total of 124 patients fulfilled the inclusion criteria. The median age was 58...

  8. Our experience in using the whole body computed tomography unit (GE CT/T)

    International Nuclear Information System (INIS)

    Murakawa, Yasuhiro; Morimoto, Mitsuo; Ishigaki, Naoya; Zaitsu, Hiroaki; Kawabata, Kohji

    1983-01-01

    Since our hospital installed the CT unit of the head and neck (SCT-100N) in April, 1979, we reported our experience in using this equipment in 1980 and 1982. After that, since the whole body CT unit (GE CT/T) was installed in our hospital in April, 1982, the total number of CT examination have reached approximately three thousand five handred till this August. Consequently, this CT image seemed to be superior in image quality to that obtained by other CT equipment. The most important characteristic of this equipment is that the retrospective and prospective reviews of the target image and the coronal and sagittal recontruction from contiguous transverse axial scans are possible. We show in this report two experimental CT photograms obtained by the reviews of the target image in using of microchart phantom and CT photograms of uterus myoma, metastatic thyroid and liver cancers and further, of contiguous transverse axial scans of cerebral embolism and the coronal recontruction. The important problems for the future of this equipment are those of absorbed X-ray dose of the patients and the scan time. (author)

  9. Fracture toughness of neutron irradiated solid and powder HIP 316L(N). ITER Task 214, NET deliverable GB6 ECN-5

    International Nuclear Information System (INIS)

    Rensman, J.; Van den Broek, F.P.; Jong, M.; Van Osch, E.V.

    1998-04-01

    The fracture toughness properties of unirradiated and neutron irradiated type 316L(N) stainless steel plate (European Reference Heat ERHII), conventional 316L(N) solid HIP joints (heat PM-130), and 316L(N)-1G powder HIP material have been measured. Compact tension specimens with a thickness of 12 and 5 mm were irradiated in the High Flux Reactor (HFR) in Petten, The Netherlands, simulating the fusion reactor's first wall conditions by a combination of high displacement damage with proportional amounts of helium. The solid HIP (or HIP-bonded) CT-specimens were irradiated in two separate experiments: SIWAS-6 with 1.3 to 2.3 dpa (1.7 dpa av.) at 353 K, and CHARIOT-3 with 2.7 to 3.1 dpa (2.9 dpa av.) at 600 K. The plate material and powder HIP CT-specimens were irradiated in one experiment only, SIWAS-6. The helium content is up to 20 appm for the 2.9 dpa (av.) dose level. Testing temperatures of 353K and 573K have been used for the fracture toughness experiments. The report contains the experimental conditions and summarises the results, which are given in terms of J-resistance curve fits. The main conclusions are that all three materials have very high toughness in the unirradiated state with little difference between them; the solid HIP has the highest toughness, the powder HIP lowest. The toughness of all three materials is reduced significantly by irradiation, the reduction is the least for the plate material and the highest for the powder HIP material. However, many, but not all, of the solid HIP CT specimens showed debonding of the joint during testing. The machined notch of the CT specimens was not exactly on the joint interface, which could lead to unjustified interpretation of the measured values as being the toughness of the joint, the toughness of the joint being probably much lower. The reduction by irradiation of the fracture toughness of the powder HIP material is clearly larger than for plate material, which is confirmed by the observed early initiation

  10. Effect of diet and 677 C-->T 5, 10-methylenetetrahydrofolate reductase genotypes on plasma homocyst(e)ine concentrations in slovak adolescent population.

    Science.gov (United States)

    Raslová, K; Bederová, A; Gasparovic, J; Blazícek, P; Smolková, B

    2000-01-01

    The objective of this study was to evaluate the effect of diet and 677 C-->T mutation of the methylenetetrahydrofolate reductase (MTHFR) gene on plasma homocyst(e)ine concentrations in an adolescent population (113 males, age: 14.2+/-2.4 years; 202 females, age: 14.9+/-2.1 years) from a region characterized by high cardiovascular mortality. Homocyst(e)ine levels did not differ between males and females (9.4+/-3.5 and 8.9+/-3.1 micromol/l, respectively). The homozygosity for the 677 C-->T MTHFR mutation was found in 4.6 % of subjects. No differences in homocyst(e)ine levels were found between MTHFR genotypes. Analysis of the diet composition which was performed on a 24-hour daily recall basis and a food frequency questionnaire showed a low daily intake of vitamin B6 (males: 1.13 mg/66% RDA; females: 0.92 mg/61% RDA). Daily folic acid intake was 0.21 g/105% RDA in males and 0.23 g/115% RDA in females. The results of our study show that the high homocyst(e)ine levels in the adolescent population were not affected by the 677 C-->T MTHFR mutation. We conclude that an insufficient dietary intake of vitamin B6 and folic acid is responsible for this finding. This is in accord with the recommendation that the dietary allowances for folate should be reset to the originally prescribed levels of 0.4 g/day which should be sufficient to control the homocysteine levels.

  11. Craniopharyngioma identification by CT and MR imaging at 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Hald, J.K. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States); Eldevik, O.P. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States); Skalpe, I.O. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States)

    1995-03-01

    To compare the detectability of craniopharyngiomas by CT and MR imaging, preoperative CT and MR studies obtained within 16 days of each other were evaluated retrospectively in 9 patients. MR imaging demonstrated cystic and solid tumor components in all 9 tumors, and enhancement in the 7 tumors that were studied after contrast medium injection. MR imaging demonstrated a signal void consistent with calcification in 4 patients. Combining unenhanced and contrast medium-enhanced studies, CT also identified all the tumors. CT demonstrated cysts in 7 lesions, calcification in 7 and enhancement in 6 of the 7 lesions that received i.v. contrast medium. Calcification was better seen by CT than MR imaging, while MR imaging identified cystic tumor components not seen on CT. The contrast medium enhancement pattern was the same with the 2 modalities. MR imaging of the sellar region, including at least one contrast medium-enhanced sequence, should be sufficient in most instances to establish a preoperative diagnosis of craniopharyngioma. (orig.).

  12. Epidemiology Study on P53 (Rs1614984 C>T Mutation in Cigarette Smokers

    Directory of Open Access Journals (Sweden)

    Dilshad Ahmad

    2017-05-01

    Full Text Available ABSTRACT Epidemiology data have established that smoking is a prime threat for the cancers, largely lung cancer. Single-nucleotide polymorphisms (SNPs,P53 SNPs have been found to be associated with the predisposition of different cancers. Their decreased expression is reported in breast and lung cancer patients. p53 (rs1614984 had been reported to be linked with the SNPs found associated with breast cancer. The primary aim of this study to determine the association of p53 variant rs1614984 with the cigarette smokers and smoking related cancers in smokers. Among the smokers, 38% were found with CC genotype, 55% were heterozygous CT and 7% were TT, respectively. The homozygous TT genotype was seen in lower percentage of smokers (7% when compared to non-smokers (8% whereas; Significant difference was not observed when encompassed by CC, CT and TT genotypes (χ2 = 4.892, p=0.087. However, CC vs CT genotype showed a significant difference between smokers and non-smokers (p=0.031, OR 1.447 (1.035-2.025 and the dominant model CC vs CT+TT was also significantly different among smoker and non-smokers (p=0.047, OR 1.39 (1.004-1.924. Furthermore, smokers are at the risk of developing variety of diseases including lung cancer. Our finding suggests a higher percentage of heterozygous CT genotype in smokers when compared to non-smokers. Therefore, this finding gives a clue that the transition mutation of C>T (rs1614984 may leads to the lung diseases including cancer in smokers. However, there will be a need of more extensive and elaborated study to set down the aspect of p53(rs1614984 C>T in lung cancer among smokers.

  13. Association SOD2 Polymorphism(-9C/T and Senile Cataract

    Directory of Open Access Journals (Sweden)

    A.R. Nakhaee

    2017-01-01

    Full Text Available Introduction: One of the most common causes of blindness around the world is cataract, which is a multifactorial eye disease and a major cause the loss lens transparency in the aging population. Oxidative stress is a major factor that often leads to cataract formation. Oxidative stress is defined as a disturbance in the balance of reactive oxygen species (ROS production  and antioxidant defenses, including enzymatic and non-enzymatic systems. One of the defense systems against free radicals is superoxide dismutase II (Mn SOD enzyme. SOD enzyme catalyses the dismutation of superoxide anion to O2 and H2O2. Several polymorphism  have been found associated with SOD2 gene. Present study has been done to evaluaet effects of genetic polymorphism, including SOD2 C/T polymorphism in the -9 position in senile cataract patiens and normal individuals. Material and methods: in this case- control study, there are 120 patients with senile cataract and 104 healthy people. We collected 2ml of whole blood in tubes containing EDTA, and then DNA extraction was performed. Polymorphisms were detected by PCR–RFLP technique. Findings: The distribution of CC, CT, TT genotypes of SOD2 gene were 28.3%, 43.3% and 28.3% in the patient group and 24%, 48.1% and 27.9% in the healthy group, respectively. Conclusion: No significant difference in the distribution SOD2 C/T polymorphism was observed between cases and controls. 

  14. Association of interleukin-1 beta (-511C/T) polymorphisms with osteoporosis in postmenopausal women

    International Nuclear Information System (INIS)

    Tai-Hung Chao; Hsing-Ning Yu; Chi-Chuan Huang; Wen-Shen Liu; Ya-Wen Tsai; Wen-Tung Wu

    2010-01-01

    Osteoporosis is a common disease of the elderly, in which genetic and clinical factors contribute to the disease phenotype. Since the production of interleukin-1 (IL-1) has been implicated in the bone mass and skeletal disorders, we investigated whether IL-1 system gene polymorphisms are associated with the pathogenesis of osteoporosis in postmenopausal Taiwanese women.Osteoporosis is diagnosed by dual-energy x-ray absorptiometry, which measures bone mineral density (BMD) at multiple skeletal sites. We studied the IL-1a (-889C/T), IL-1 (-511C/T) and the 86 base pair variable number tandem repeat (VNTR) in intron 2 of the IL-1 receptor antagonist (IL-1ra) gene in 117 postmenopausal women with osteoporosis and 135 control subjects without a history of symptomatic osteoporosis. These gene polymorphisms were analyzed by polymerase chain reaction and restriction fragment length polymerase. Blood sugar and other risk factors were also determined.The frequencies of IL-1 (-511C/T) genotypes (P=.022, odds ratio=1.972) and alleles (P=.02, odds ratio=2.909) showed a statistically significant difference between the two groups. However, we did not find any statistically significant difference in IL-1 and IL-1ra polymorphisms (P>.05). We also observed a positive relationship between osteoporosis and cholesterol and a weak inverse relationship between blood sugar and osteoporosis in postmenopausal women.These experimental results suggest that the pathogenesis of osteoporosis is associated with IL-1 (-511C/T) polymorphism in postmenopausal women. This polymorphism is an independent risk factor for osteoporosis (Author).

  15. Thermogravimetric studies of the thermo-oxidative stability of irradiated and unirradiated polyethylene

    International Nuclear Information System (INIS)

    Novakovic, L.; Gal, O.; Markovic, V.; Stannett, V.T.

    1985-01-01

    In part one of this series the effects of a phenolic, an amine and a thioester antioxidant on the thermo-oxidative stability of irradiated and unirradiated low-density polyethylene was reported. In this paper the effects of combined phenolic and thioester stabilizers are described. Isothermal thermogravimetric analysis was used to study the systems. Pronounced synergism was observed with the induction periods, the time when the initial weight loss begins and the 5% weight loss. At about 50% of each stabilizer increases greater than twofold were observed both with the unirradiated and irradiated polymers. The rate constants for oxygen uptake were decreased. However, the rates of degradation at 5% weight loss fell between the values of the two pure stabilizers with no pronounced synergism in either case. In the absence of oxygen little effect of either antioxidant or their mixtures was observed. The corresponding activation energies were somewhat higher, however, with the irradiated samples containing antioxidants. Dynamic thermogravimetry was used for this study. A kinetic analysis indicated that there were somewhat different modes of degradation at lower- and higher-temperature ranges. (author)

  16. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    International Nuclear Information System (INIS)

    Lutterbey, G.; Grohe, C.; Gieseke, J.; Falkenhausen, M. von; Morakkabati, N.; Wattjes, M.P.; Manka, R.; Trog, D.; Schild, H.H.

    2007-01-01

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  17. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    Energy Technology Data Exchange (ETDEWEB)

    Lutterbey, G. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)]. E-mail: goetz.lutterbey@ukb.uni-bonn.de; Grohe, C. [Department of Internal Medicine, University of Bonn (Germany); Gieseke, J. [PHILIPS Medical Systems, Best (Netherlands); Falkenhausen, M. von [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Morakkabati, N. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Wattjes, M.P. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Manka, R. [Department of Internal Medicine, University of Bonn (Germany); Trog, D. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Schild, H.H. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)

    2007-02-15

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  18. Irradiation effects on fracture toughness of two high-copper submerged-arc welds, HSSI series 5

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Haggag, F.M.; McCabe, D.E.; Iskander, S.K.; Bowman, K.O.; Menke, B.H.

    1992-10-01

    The Fifth Irradiation Series in the Heavy-Section Steel irradiation (HSSI) Program was aimed at obtaining a statistically significant fracture toughness data base on two weldments with high-copper contents to determine the shift and shape of the K lc curve as a consequence of irradiation. The program included irradiated Charpy V-notch impact, tensile, and drop-weight specimens in addition to compact fracture toughness specimens. Compact specimens with thicknesses of 25.4, 50.8, and 101.6 mm [1T C(T), 2T C(T), and 4T C(T), respectively] were irradiated. Additionally, unirradiated 6T C(T) and 8T C(T) specimens with the same K lc measuring capacity as the irradiated specimens were tested. The materials for this irradiation series were two weldments fabricated from special heats of weld wire with copper added to the melt. One lot of Linde 0124 flux was used for all the welds. Copper levels for the two welds are 0.23 and 0.31 wt %, while the nickel contents for both welds are 0.60 wt %. Twelve capsules of specimens were irradiated in the pool-side facility of the Oak Ridge Research Reactor at a nominal temperature of 288 degree C and an average fluence of about 1.5 x 10 19 neutrons/cm 2 (> 1 MeV). This volume, Appendices E and F, contains the load-displacement curves and photographs of the fracture toughness specimens from the 72W weld (0.23 wt % Cu) and the 73 W weld (0.31 wt % Cu), respectively

  19. Characterization of un-irradiated and irradiated reactor graphite; Karakterizacija neozracenog i ozracenog reaktorskog grafita

    Energy Technology Data Exchange (ETDEWEB)

    Marinkovic, S [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1965-11-15

    This report contains three parts: characterization of Yugoslav nuclear graphite development of methods and obtained results, characterization of un-irradiated and irradiated domestic nuclear graphite; calculation of electrical conductivity changes due to vacancies in the graphite crystal lattice.

  20. MRT versus CT in the diagnosis of pneumonia. Evaluation of a T2-weighted utrafast turbo-spin-echo sequence (UTSE)

    International Nuclear Information System (INIS)

    Leutner, C.; Lutterbey, G.; Kuhl, C.K.; Flacke, S.; Schild, H.H.; Glasmacher, A.; Theisen, A.; Wardelmann, E.; Grohe, C.

    1999-01-01

    Purpose: To evaluate a T 2 -weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T 2 -weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR eff /T E /Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary abscesses. In 93% the image quality of the MRT was very good to good. Conclusions: MRT in the technique presented here is in most cases equal to CT for the detection of pneumonia. Diagnosis of pulmonary abscesses seems to be better with MRT. (orig.) [de

  1. Characteristic CT and MRI findings of intracranial chondroma

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Fuhong; Qiu, Shijun; Liu, Zhenyin; Lv, Xiaofei; Feng, Xia; Xiong, Wei; An, Jie; Chen, Jing; Yang, Weicong; Wen, Chuhong [Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong (China)], E-mail: qiushijun006@163.com; Jiang, Jianwei; Chang, Jun [Department of Radiology, The Third Affiliated Hospital of Nantong University, Wuxi, Jiangsu (China)

    2012-12-15

    Background. Intracranial chondromas are rare benign tumors. To date, few data are available on their neuroradiological features. Purpose. To describe a series of patients with intracranial chondroma and to analyze and discuss the computed tomography (CT) and magnetic resonance imaging (MRI) features that may distinguish chondromas from other intracranial neoplasms. Material and Methods. We retrospectively analyzed clinical and medical imaging data of six patients who had pathologically confirmed intracranial chondromas in our two institutions between July 2006 and September 2011. Both CT and MRI scanning were performed in all six cases. Results. Five tumors were located at the skull base and one originated from the falx. CT images revealed well-demarcated, irregular lobulated and variable density masses with obvious calci?cation (6/6), no or slight enhancement, without peritumoral edema, and frequently accompanied by erosion and destruction of surrounding bone (5/6). Tumor parenchyma appeared heterogeneously hypointense on T1WI, and hyperintense or mixed hyperintense and hypointense on T2WI, while the calcification appeared hypointense on T1WI and T2WI in five cases, demonstrating significant inhomogeneous enhancement on postcontrast MRI, which revealed the typical 'punica granatum seeds' sign. Only one case showed homogeneous low signal intensity on T1WI and high signal intensity on T2WI, and relatively uniform obvious enhancement on postcontrast scans. Conclusion. These characteristic CT and MR findings, combined with the location of the lesions and the history of a long duration of clinical symptoms, may prove helpful in differentiating intracranial chondromas from other more common tumors.

  2. Characteristic CT and MRI findings of intracranial chondroma

    International Nuclear Information System (INIS)

    Duan, Fuhong; Qiu, Shijun; Liu, Zhenyin; Lv, Xiaofei; Feng, Xia; Xiong, Wei; An, Jie; Chen, Jing; Yang, Weicong; Wen, Chuhong; Jiang, Jianwei; Chang, Jun

    2012-01-01

    Background. Intracranial chondromas are rare benign tumors. To date, few data are available on their neuroradiological features. Purpose. To describe a series of patients with intracranial chondroma and to analyze and discuss the computed tomography (CT) and magnetic resonance imaging (MRI) features that may distinguish chondromas from other intracranial neoplasms. Material and Methods. We retrospectively analyzed clinical and medical imaging data of six patients who had pathologically confirmed intracranial chondromas in our two institutions between July 2006 and September 2011. Both CT and MRI scanning were performed in all six cases. Results. Five tumors were located at the skull base and one originated from the falx. CT images revealed well-demarcated, irregular lobulated and variable density masses with obvious calci?cation (6/6), no or slight enhancement, without peritumoral edema, and frequently accompanied by erosion and destruction of surrounding bone (5/6). Tumor parenchyma appeared heterogeneously hypointense on T1WI, and hyperintense or mixed hyperintense and hypointense on T2WI, while the calcification appeared hypointense on T1WI and T2WI in five cases, demonstrating significant inhomogeneous enhancement on postcontrast MRI, which revealed the typical 'punica granatum seeds' sign. Only one case showed homogeneous low signal intensity on T1WI and high signal intensity on T2WI, and relatively uniform obvious enhancement on postcontrast scans. Conclusion. These characteristic CT and MR findings, combined with the location of the lesions and the history of a long duration of clinical symptoms, may prove helpful in differentiating intracranial chondromas from other more common tumors

  3. Relationship between IL-10 gene -819C/T polymorphism and the ...

    African Journals Online (AJOL)

    Background: The -819C/T polymorphism in interleukin 10 (IL-10) gene has been reported to be associated with inflammatory bowel disease (IBD) ,but the previous results are conflicting. Materials and methods: The present study aimed at investigating the association between this polymorphism and risk of IBD using a ...

  4. Dissolution experiments of unirradiated uranium dioxide pellets

    International Nuclear Information System (INIS)

    Ollila, K.

    1985-01-01

    The purpose of this study was to measure the dissolution rate of uranium from unirradiated uranium dioxide pellets in deionized water and natural groundwater. Moreover, the solubility limit of uranium in natural groundwater was measured. Two different temperatures, 25 and 60 deg C were used. The low oxygen content of deep groundwater was simulated. The dissolution rate of uranium varied from 10 -7 to 10 -8 g cm -2 d -1 . The rate in reionized water was one order of magnitude lower than in groundwater. No great difference was observed between the natural groundwaters with different composition. Temperature seems to have effect on the dissolution rate. The solubility limit of uranium in natural groundwater in reducing conditions, at 25 deg C, varied from 20 to 600 μg/l and in oxidizing conditions, at 60 deg C, from 4 to 17 mg/l

  5. Relationship of the FKBP5 C/T polymorphism with dysfunctional attitudes predisposing to depression.

    Science.gov (United States)

    Suzuki, Akihito; Matsumoto, Yoshihiko; Sadahiro, Ryoichi; Enokido, Masanori; Goto, Kaoru; Otani, Koichi

    2014-08-01

    FK506-binding protein 51 (FKBP5) is a co-chaperone of the glucocorticoid receptor, and plays an important role in the negative feedback regulation of the hypothalamic-pituitary-adrenal axis. The C/T single nucleotide polymorphism in the intron 2 of the FKBP5 gene affects cortisol secretion, and has been implicated in the pathophysiology of depression. In this study, the relationship of the FKBP5 C/T polymorphism with dysfunctional attitudes predisposing to depression was examined. The subjects were 300 healthy Japanese. The FKBP5 genotypes were determined by a real-time PCR and cycling probe technology for SNP typing. Dysfunctional attitudes were assessed by the 24-item version of the Dysfunctional Attitude Scale (DAS-24), which has the Achievement, Self-control, and Dependency subscales. DAS-24 total scores were significantly higher in the group with the T allele than in that without this allele (p=0.001). Regarding the subscales, scores of the Achievement (p=0.003) and Self-control (p=0.009) subscales, but not those of the Dependency subscale, were significantly higher in the former group than in the latter group. The present study suggests that the FKBP5 C/T polymorphism is implicated in formation of dysfunctional attitudes, especially those about achievement and self-control. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Characterization of un-irradiated MIMAS MOX fuel by Raman spectroscopy and EPMA

    Science.gov (United States)

    Talip, Zeynep; Peuget, Sylvain; Magnin, Magali; Tribet, Magaly; Valot, Christophe; Vauchy, Romain; Jégou, Christophe

    2018-02-01

    In this study, Raman spectroscopy technique was implemented to characterize un-irradiated MIMAS (MIcronized - MASter blend) MOX fuel samples with average 7 wt.% Pu content and different damage levels, 13 years after fabrication, one year after thermal recovery and soon after annealing, respectively. The impacts of local Pu content, deviation from stoichiometry and self-radiation damage on Raman spectrum of the studied MIMAS MOX samples were assessed. MIMAS MOX fuel has three different phases Pu-rich agglomerate, coating phase and uranium matrix. In order to distinguish these phases, Raman results were associated with Pu content measurements performed by Electron Microprobe Analysis. Raman results show that T2g frequency significantly shifts from 445 to 453 cm-1 for Pu contents increasing from 0.2 to 25 wt.%. These data are satisfactorily consistent with the calculations obtained with Gruneisen parameters. It was concluded that the position of the T2g band is mainly controlled by Pu content and self-radiation damage. Deviation from stoichiometry does not have a significant influence on T2g band position. Self-radiation damage leads to a shift of T2g band towards lower frequency (∼1-2 cm-1 for the UO2 matrix of damaged sample). However, this shift is difficult to quantify for the coating phase and Pu agglomerates given the dispersion of high Pu concentrations. In addition, 525 cm-1 band, which was attributed to sub-stoichiometric structural defects, is presented for the first time for the self-radiation damaged MOX sample. Thanks to the different oxidation resistance of each phase, it was shown that laser induced oxidation could be alternatively used to identify the phases. It is demonstrated that micro-Raman spectroscopy is an efficient technique for the characterization of heterogeneous MOX samples, due to its low spatial resolution.

  7. Role of C677T and A1298C MTHFR, A2756G MTR and -786 C/T eNOS gene polymorphisms in atrial fibrillation susceptibility.

    Directory of Open Access Journals (Sweden)

    Betti Giusti

    Full Text Available BACKGROUND: Hyperhomocysteinemia has been suggested to play a role in the NonValvular Atrial Fibrillation (NVAF pathogenesis. Polymorphisms in genes coding for homocysteine (Hcy metabolism enzymes may be associated with hyperhomocysteinemia and NVAF. METHODOLOGIES: 456 NVAF patients and 912 matched controls were genotyped by an electronic microchip technology for C677T and A1298C MTHFR, A2756G MTR, and -786C/T eNOS gene polymorphisms. Hcy was determined by an immunoassay method. PRINCIPAL FINDINGS: The genotype distribution of the four polymorphisms as well as genotype combinations did not differ in patients and controls. Hcy was higher in patients than in controls (15.2, 95%CI 14.7-15.7 vs 11.3, 95%CI 11.0-11.6 micromol/L; p<0.0001. In both populations, a genotype-phenotype association (p<0.0001 between Hcy and C677T MTHFR polymorphism was observed; in controls a significant (p = 0.029 association between tHcy and -786C/T eNOS polymorphism was also observed. At the multivariate analysis the NVAF risk significantly increased in the upper quartiles of Hcy compared to the lowest: OR from 2.8 (1.68-4.54 95%CI in Q2 to 12.9 (7.96-21.06 95%CI in Q4. CONCLUSIONS: Our data demonstrated the four polymorphisms, although able, at least in part, to affect Hcy, were not associated with an increased risk of NVAF per se or in combination.

  8. The dissolution of unirradiated UO2 fuel pellets under simulated disposal conditions

    International Nuclear Information System (INIS)

    Ollila, K.; Leino-Forsman, H.

    1993-03-01

    The dissolution behaviour of unirradiated UO 2 pellets was studied as a function of water composition under oxidizing and reducing conditions at 25 deg C. The waters included deionized water as the reference water, sodium bicarbonate solutions with varying bicarbonate content, and two different synthetic groundwaters. The release of uranium was measured during static batch dissolution experiments of long duration (3-4 years)

  9. The Catalase –262C/T Promoter Polymorphism and Diabetic Complications in Caucasians with Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Kátia Gonçalves dos Santos

    2006-01-01

    Full Text Available Catalase is a central antioxidant enzyme constituting the primary defense against oxidative stress. In this study, we investigated whether the functional –262C/T polymorphism in the promoter of catalase gene is associated with the presence of diabetic retinopathy (DR, diabetic nephropathy (DN and ischemic heart disease (IHD in 520 Caucasian-Brazilians with type 2 diabetes. The –262C/T polymorphism was also examined in 100 Caucasian blood donors. Patients underwent a clinical and laboratory evaluation consisting of a questionnaire, physical examination, assessment of diabetic complications and laboratory tests. Genotype analysis was performed using the polymerase chain reaction followed by digestion with restriction enzyme. The genotype and allele frequencies of the –262C/T polymorphism in patients with type 2 diabetes were very similar to those of blood donors (T allele frequency = 0.20 and 0.18, respectively. Likewise, there were no differences in either genotype or allele frequencies between type 2 diabetic patients with or without DR, DN or IHD. Thus, our results do not support the hypothesis that the –262C/T polymorphism is related to the development of DR, DN or IHD in patients with type 2 diabetes. Further studies are necessary to elucidate the role of catalase gene polymorphisms in the pathogenesis of diabetic complications.

  10. Craving for alcohol and food during treatment for alcohol dependence: modulation by T allele of 1519T>C GABAAalpha6.

    Science.gov (United States)

    Han, Doug Hyun; Bolo, Nicholas; Daniels, Melissa A; Lyoo, In Kyoon; Min, Kyung Joon; Kim, Chang Hyun; Renshaw, Perry F

    2008-09-01

    Craving for alcohol and food has been studied in association with alcohol dependence and eating disorders, respectively. One subclass of the gamma-aminobutyric acid (GABA) receptor, 1519T>C GABA(A)alpha6 has been reported to be associated with both alcohol dependence and weight gain. In this study, we hypothesized that patients being treated for alcohol dependence would report decreased craving for alcohol, but an increased craving for food during a 4-week treatment period. We further hypothesized that the T allele of the 1519T>C GABA(A)alpha6 gene would modulate the extent of changes in craving for alcohol and food. This study included 98 male inpatients being treated for alcohol dependence. A 7-point visual analog scale was applied to evaluate relative levels of alcohol and food craving at baseline and again 4 weeks later. Body weight was also checked at the same periods. Genotyping of the 1519T>C SNP in GABA(A)alpha6 was carried out by restriction fragment length polymorphism. There were significant changes in craving for alcohol and food in all patients with alcohol dependence. During the treatment period, body weight increased in all patients with alcohol dependence. Changes in alcohol and food craving in T-allele carriers (CT + TT) of 1519T>C GABA(A)alpha6 were greater than those observed in CC homozygotes. In T-allele carriers, body weight significantly increased and the changes in weight showed a negative correlation with the change in the craving for alcohol and a positive correlation with the changes in craving for food. The current results suggest that in T-allele carriers the change in craving for alcohol during treatment for alcohol dependence is negatively associated with changes in craving for food. The T allele of the 1519T>C GABA(A)alpha6 gene may be one of the modulating factors associated with changes in craving for alcohol and food during treatment of patients with alcohol dependence.

  11. An analysis of facial nerve function in irradiated and unirradiated facial nerve grafts

    International Nuclear Information System (INIS)

    Brown, Paul D.; Eshleman, Jeffrey S.; Foote, Robert L.; Strome, Scott E.

    2000-01-01

    Purpose: The effect of high-dose radiation therapy on facial nerve grafts is controversial. Some authors believe radiotherapy is so detrimental to the outcome of facial nerve graft function that dynamic or static slings should be performed instead of facial nerve grafts in all patients who are to receive postoperative radiation therapy. Unfortunately, the facial function achieved with dynamic and static slings is almost always inferior to that after facial nerve grafts. In this retrospective study, we compared facial nerve function in irradiated and unirradiated nerve grafts. Methods and Materials: The medical records of 818 patients with neoplasms involving the parotid gland who received treatment between 1974 and 1997 were reviewed, of whom 66 underwent facial nerve grafting. Fourteen patients who died or had a recurrence less than a year after their facial nerve graft were excluded. The median follow-up for the remaining 52 patients was 10.6 years. Cable nerve grafts were performed in 50 patients and direct anastomoses of the facial nerve in two. Facial nerve function was scored by means of the House-Brackmann (H-B) facial grading system. Twenty-eight of the 52 patients received postoperative radiotherapy. The median time from nerve grafting to start of radiotherapy was 5.1 weeks. The median and mean doses of radiation were 6000 and 6033 cGy, respectively, for the irradiated grafts. One patient received preoperative radiotherapy to a total dose of 5000 cGy in 25 fractions and underwent surgery 1 month after the completion of radiotherapy. This patient was placed, by convention, in the irradiated facial nerve graft cohort. Results: Potential prognostic factors for facial nerve function such as age, gender, extent of surgery at the time of nerve grafting, preoperative facial nerve palsy, duration of preoperative palsy if present, or number of previous operations in the parotid bed were relatively well balanced between irradiated and unirradiated patients. However

  12. Genetic polymorphism 609C>T in NAD(P)H:quinone oxidoreductase 1 enhances the risk of proximal colon cancer

    NARCIS (Netherlands)

    Freriksen, J.J.; Salomon, J.; Roelofs, H.M.; Morsche, R.H. te; Stappen, J.W. van der; Dura, P.; Witteman, B.J.; Lacko, M.; Peters, W.H.

    2014-01-01

    Gastrointestinal (GI) cancer is responsible for the majority of deaths among all types of cancer. Lifestyle factors may not only be the main risk factor for GI cancer but reactive oxygen species (ROS) may also be involved. The single-nucleotide polymorphisms (SNPs) 609C>T (rs1800566) and 465C>T

  13. CT staging of renal cell carcinoma using the revised 1997 TNM staging criteria: in comparison with the previous one

    International Nuclear Information System (INIS)

    Sung, Deuk Jae; Kim, Yun Hwan; Chung, Hwan Hoon; Chung, Kyoo Byung; Suh, Won Hyuck

    2001-01-01

    To assess the accuracy of preoperative CT staging of RCC and to compare the relationship between T stage and the incidence of metastasis on the basis of the old (1992) and the new (1997) UICC and AJCC tumor classification system. In 112 cases of surgically resected RCC, the stagings of preoperative CT scans were determined retrospectively by two radiologists and were compared with the results of pathologic examinations. In 70 cases which had been followed up over three years after surgery, the incidence of metastasis at initial diagnosis and during the follow-up period was assessed. All cases were reconsidered, and using the old and the new TNM classification, the incidence of metastasis was compared. According to the old TNM classification, 5 cases (4%) were staged at T1, 73(65%) at T2, 21(19%) at T3a, 9(8%) at T3b, 0 at T3c, and 4(4%) at T4. Using the new TNM classification, we also staged 54 cases (48%) at T1 and 24(21%) at T2. Overall, using this new classification, CT correctly staged 79% of patients (88/112) overstaged 15%(17/112) and understaged 6%(7/112). CT had a sensitivity of 84% and specificity of 91% in new T1 tumors, 71% and 95%, respectively, in new T2 tumors, 69% and 88% in T3a tumors, 78% and 98% in T3b tumors, and 75% and 99% in T4 tumors. CT had a sensitivity of 44% and a specificity of 99% in old T1 tumors, and 82% and 71%, respectively, in old T2 tumors. The incidence of metastasis in CT-staged (cT) tumors was 0% (0/4) in old cT1, 8% (3/39) in new cT1, 29% (4/14) in new cT2, 67% (6/9) in cT3a, and 75% (6/8) in cT3b. In the staging of T1 tumors, CT is more sensitive when the new TNM classification is used. Even though the cut off point between T1 and T2 tumors had been in creased from 2.5 to 7.0 cm, T1 tumors staged according to the new system did not show a significantly higher incidence of metastasis than those staged according to the old

  14. Evaluation of paracavernous cranial nerves (3rd to 6th) with CT

    International Nuclear Information System (INIS)

    Tsuha, Mitsuru; Okamura, Tomomi; Abiko, Seisho; Aoki, Hideo

    1984-01-01

    We have now used CT to evaluate the cavernous sinuses, especially the 3rd, 4th, 5th, and 6th cranial nerves. adjacent to them. Twenty cases, presumably all having sellar or parasellar lesions, were examined by means of thin-slice (2-4 mm) axial and coronal (including both direct and reconstructed methods) CT studies. Moreover, three blocks of the sellar region obtained from adult cadavers were examined beforehand by CT scan, and the courses of the respective paracavernous cranial nerves were confirmed by microsurgical dissection. As a result, the following conclusions were obtained. 1. It was valuable to perform a post-enhanced direct coronal study for the definite identification of the paracavernous cranial nerves (3rd to 6th cranial nerves). 2. Also valuable was a magnified CT film of the parasellar regions, which made the identification of the parasellar cranial nerves clearer. 3. In the clinical cases showing a normal shape of the cavernous sinuses on CT, each cranial nerve was evaluated. In the axial studies (almost 10 to 15 degrees anterior to Reid's basal line), the frequencies of the identification of the 3rd, 5th, and 6th cranial nerves were 76%, 97% (as to the Gasserian ganglion), and 21% respectively. None of the 4th cranial nerve was visualized in the cases examined. On the other hand, the frequencies of the identification of the 3rd, 5th, and 6th cranial nerves were 83%, 86%, and 21% respectively in the direct coronal studies and 62%, 57%, and 4% in those of the reconstructed films. The visualization of each cranial nerve in the direct coronal study was better than when the reconstructed method was used. Finally, a schematic presentation of the cranial nerves adjacent to the cavernous sinuses was made in the axial and coronal projections. (J.P.N.)

  15. CT and MR manifestations of acute methyl alcohol toxic encephalopathy

    International Nuclear Information System (INIS)

    Mao Xiaofen; Yang Bo; Ye Gengxin; Zhang Cheng

    2009-01-01

    Objective: To analyze the CT and MR manifestations of methyl alcohol toxic encephalopathy and to improve the diagnosing value of CT and MRI. Methods: 40 patients with methyl alcohol intoxication were collected in this study, in which CT scan was performed on 40 cases and MRI on 4 cases. All CT and MRI radiological data of brain were retrospectively studied. Results: 13 of 40 cases showed abnormal findings on brain CT and MRI. The most common manifestation (6/13, 46%)was hypodensity in frontal parietal white matter and external capsule-putamen on CT, which showed long or short T1 and long T2 on MR. Hemorrhage in right putamen was found only in 1 patient (1/13,7%). CT showed low density inbilateral external capsule in 4 cases (4/13,31%), in which MR showed long or short T1 and long T2. Low density lesions in subcortical white matter of bilateral frontal and parietal lobes, cingulate gyms and insular lobes were found in 2 patients (2/13,15%). The more severe clinic manifestation, the more obvious brain lesion CT and MRI showed. Conclusion: Brain CT and MR manifestations have great diagnostic value of acute methyl alcohol toxic encephalopathy. MRI was more sensitive and better than CT in finding early brain damage caused by methanol intoxication. (authors)

  16. Evaluation of tumor recurrences after radical prostatectomy using 18F-Choline PET/CT and 3T multiparametric MRI without endorectal coil: a single center experience.

    Science.gov (United States)

    Couñago, Felipe; Recio, Manuel; Maldonado, Antonio; Del Cerro, Elia; Díaz-Gavela, Ana Aurora; Thuissard, Israel J; Sanz-Rosa, David; Marcos, Francisco José; Olaciregui, Karmele; Mateo, María; Cerezo, Laura

    2016-12-07

    To evaluate and compare the utility of 18F-fluorocholine (18F-CH) PET/CT versus 3-Tesla multiparametric MRI (mpMRI) without endorectal coil to detect tumor recurrences in patients with biochemical relapse following radical prostatectomy (RP). Secondarily, to identify possible prognostic variables associated with mpMRI and 18F-CH PET/CT findings. Retrospective study of 38 patients who developed biochemical recurrence after RP between the years 2011 and 2015 at our institution. PET/CT and mpMRI were both performed within 30 days of each other in all patients. The PET/CT was reviewed by a nuclear medicine specialist while the mpMRI was assessed by a radiologist, both of whom were blinded to outcomes. The median prostate-specific antigen (PSA) value pre-MRI/PET-CT was 0.9 ng/mL (interquartile range 0.4-2.2 ng/mL). There were no differences in the detection rate between 18F-CH PET/CT and mpMRI for local recurrence (LR), lymph node recurrence (LNR) and bone metastases (BM). Separately, mpMRI and 18F-CH PET/CT were positive for recurrence in 55.2% and 52.6% of cases, respectively, and in 65.7% of cases when findings from both modalities were considered together. The detection of LR was better with combined mpMRI and choline PET/CT versus choline PET/CT alone (34.2% vs 18.4%, p = 0.04). Salvage treatment was modified in 22 patients (57.8%) based on the imaging findings. PSA values on the day of biochemical failure were significantly associated with mpMRI positivity (adjusted odds ratio (OR): 30.9; 95% confidence interval (CI): 1.5-635.8). Gleason score > 7 was significantly associated with PET/CT positivity (OR: 13.9; 95% CI: 1.5-125.6). A significant association was found between PSA doubling time (PSADT) (OR: 1.3; 95% CI: 1.0-1.7), T stage (OR: 21.1; 95% CI: 1.6-272.1), and LR. Multiparametric MRI and 18F-CH PET/CT yield similar detection rates for LR, LNR and pelvic BM. The combination of both imaging techniques provides a better LR detection versus choline

  17. 18F-FDG-PET/CT parameters as imaging biomarkers in oral cavity squamous cell carcinoma, is visual analysis of PET and contrast enhanced CT better than the numbers?

    Energy Technology Data Exchange (ETDEWEB)

    Kendi, A.Tuba, E-mail: ayse.kendi@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Corey, Amanda [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Magliocca, Kelly R. [Department of Pathology, Emory University, Atlanta, GA (United States); Nickleach, Dana C. [Biostatistics & Bioinformatics Shared Resource at Winship Cancer Institute of Emory University, Atlanta, GA (United States); Galt, James [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Switchenko, Jeffrey M. [Biostatistics & Bioinformatics Shared Resource at Winship Cancer Institute of Emory University, Atlanta, GA (United States); El-Deiry, Mark W.; Wadsworth, J. Trad [Otolaryngology Head and Neck Surgery, Emory University, Atlanta, GA (United States); Hudgins, Patricia A. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Saba, Nabil F. [Hematology Oncology, Winship Cancer Institute of Emory University, Atlanta, GA (United States); Schuster, David M. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States)

    2015-06-15

    multivariable analysis, patients with high (≥ median) tumor SUV max (OR 6.3), SUV mean (OR 6.3), MTV (OR 19.0), TLG (OR 19.0), SAM (OR 11.7) and N SAM (OR 19.0) had high pathological T-stage (T3/T4) (p < 0.05). Ring/heterogeneous pattern on CECT qualitative assessment was associated with worse DMFS and OS. Conclusion: High PET/CT parameters were associated with pathologically advanced T stage (T3/T4). Qualitative assessment of CECT has prognostic value. PET/CT parameters did not predict clinical outcome.

  18. 18F-FDG-PET/CT parameters as imaging biomarkers in oral cavity squamous cell carcinoma, is visual analysis of PET and contrast enhanced CT better than the numbers?

    International Nuclear Information System (INIS)

    Kendi, A.Tuba; Corey, Amanda; Magliocca, Kelly R.; Nickleach, Dana C.; Galt, James; Switchenko, Jeffrey M.; El-Deiry, Mark W.; Wadsworth, J. Trad; Hudgins, Patricia A.; Saba, Nabil F.; Schuster, David M.

    2015-01-01

    multivariable analysis, patients with high (≥ median) tumor SUV max (OR 6.3), SUV mean (OR 6.3), MTV (OR 19.0), TLG (OR 19.0), SAM (OR 11.7) and N SAM (OR 19.0) had high pathological T-stage (T3/T4) (p < 0.05). Ring/heterogeneous pattern on CECT qualitative assessment was associated with worse DMFS and OS. Conclusion: High PET/CT parameters were associated with pathologically advanced T stage (T3/T4). Qualitative assessment of CECT has prognostic value. PET/CT parameters did not predict clinical outcome

  19. 4 T MRI of chondrocalcinosis in combination with three-dimensional CT, radiography, and arthroscopy: a report of three cases

    International Nuclear Information System (INIS)

    Suan, J.C.; Chhem, R.K.; Gati, J.S.; Norley, C.J.; Holdsworth, D.W.

    2005-01-01

    To describe 4 T MRI techniques in imaging chondrocalcinosis within the knee and examine the results together with those demonstrated using three-dimensional (3D) computed tomography, conventional radiography, and arthroscopy. From a larger clinical imaging study of early osteoarthritis, knee arthroscopy patients were imaged using high-field MRI and high-resolution 3D CT prior to their surgery. Retrospective review of the imaging data diagnosed three patients with chondrocalcinosis. Fat-suppressed 3D spoiled gradient (3D SPGR) and two-dimensional fat-suppressed fast spin echo (FSE) imaging was performed at 4 T. The MR images, multi-planar reformatted CT (MPR-CT) and maximum intensity projection CT (MIP-CT) images, and radiographs were examined by a musculoskeletal radiologist for the presence and location of chondrocalcinosis. The findings from arthroscopy were also included. MRI showed 16 sites of punctate hypointense regions from 18 articular surfaces and five of six menisci with similar signal characteristics. Both meniscal chondrocalcinosis and meniscal tears were clearly visible using the 3D SPGR sequence. Only three sites were demonstrated to have calcification using MPR-CT and MIP-CT revealed an additional three. In articular cartilage surfaces showing surface disruption, arthroscopy demonstrated 11 sites with crystal deposition. Arthroscopy also revealed five menisci with calcification present. Our preliminary findings suggest that imaging chondrocalcinosis using spoiled gradient 4 T MRI is superior and complementary to the other imaging modalities in the detection of crystal deposition in both articular cartilage and menisci. (orig.)

  20. 4 T MRI of chondrocalcinosis in combination with three-dimensional CT, radiography, and arthroscopy: a report of three cases

    Energy Technology Data Exchange (ETDEWEB)

    Suan, J.C.; Chhem, R.K.; Gati, J.S.; Norley, C.J.; Holdsworth, D.W. [Robarts Research Institute, Imaging Research Laboratories, London, Ontario (Canada)

    2005-11-01

    To describe 4 T MRI techniques in imaging chondrocalcinosis within the knee and examine the results together with those demonstrated using three-dimensional (3D) computed tomography, conventional radiography, and arthroscopy. From a larger clinical imaging study of early osteoarthritis, knee arthroscopy patients were imaged using high-field MRI and high-resolution 3D CT prior to their surgery. Retrospective review of the imaging data diagnosed three patients with chondrocalcinosis. Fat-suppressed 3D spoiled gradient (3D SPGR) and two-dimensional fat-suppressed fast spin echo (FSE) imaging was performed at 4 T. The MR images, multi-planar reformatted CT (MPR-CT) and maximum intensity projection CT (MIP-CT) images, and radiographs were examined by a musculoskeletal radiologist for the presence and location of chondrocalcinosis. The findings from arthroscopy were also included. MRI showed 16 sites of punctate hypointense regions from 18 articular surfaces and five of six menisci with similar signal characteristics. Both meniscal chondrocalcinosis and meniscal tears were clearly visible using the 3D SPGR sequence. Only three sites were demonstrated to have calcification using MPR-CT and MIP-CT revealed an additional three. In articular cartilage surfaces showing surface disruption, arthroscopy demonstrated 11 sites with crystal deposition. Arthroscopy also revealed five menisci with calcification present. Our preliminary findings suggest that imaging chondrocalcinosis using spoiled gradient 4 T MRI is superior and complementary to the other imaging modalities in the detection of crystal deposition in both articular cartilage and menisci. (orig.)

  1. Comparison of SPECT and CT in detecting skull base invasion in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Zhang Li; Wang Jinchuan; Pu Nuo; Song Wenzhong; Chen Mingxi

    2002-01-01

    Objective: To investigate the detecting ability of single photon emission computed tomography (SPECT) and CT in skull base invasion in nasopharyngeal carcinoma. Methods: Sixty-three patients with nasopharyngeal carcinoma were examined by whole body and skull base SPECT and CT of nasopharynx and skull base before radiotherapy. The results were double-blind compared and evaluated. Results: The overall positive rates of skull base invasion detected by SPECT and CT were 63.5% and 25.4%. In patients with headache, cranial nerve palsy and both, they were 87.9%, 93.3%, 92.3% and 42.4%, 46.7%, 46.2%. In patients with T 1 + T 2 and T 3 + T 4 lesions, they were 37.5%, 90.3% and 0.0%, 51.6%. In patients with N 0 + N 1 and N 2 + N 3 lesions, they were 63.9%, 63.0% and 19.4%, 33.3%. The positive rates of SPECT were higher than those of CT (McNemar Test, P < 0.05). The conformation rate between SPECT and CT was 61.9% and the dissimilitude rate was 38.1%. Binary Logistic regression analysis showed that headache and T stages were risk factors of positive SPECT rate (ORheadache = 3.864, ORTstage= 6.422) while Tstage and Nstage were the risk factors for positive CT rate (ORTstage = 48.932, ORNstage = 2.860). Conclusions: The detection sensitivity of SPECT in skull base invasion in nasopharyngeal carcinoma is superior to that of CT. But its specificity is inferior to that of CT. The detecting results in SPECT are better related to symptoms, signs and stage. Combining headache and cranial nerve palsy with T and N stage, the authors may much improve the results of SPECT and CT in the detection of skull base invasion in nasopharyngeal carcinoma. Further study is warranted

  2. Evaluation of occurring complications after flow diverter treatment of elastase-induced aneurysm in rabbits using micro-CT and MRI at 9.4 T

    Energy Technology Data Exchange (ETDEWEB)

    Simgen, Andreas; Ley, Desiree; Muehl-Benninghaus, Ruben; Koerner, Heiko; Reith, Wolfgang; Yilmaz, Umut [Saarland University Hospital, Department of Neuroradiology, Homburg, Saar (Germany); Roth, Christian [Clinic Bremen-Mitte, Department of Neuroradiology, Bremen (Germany); Cattaneo, Giorgio Franco Maria [Acandis GmbH, Pforzheim (Germany); Mueller, Andreas [Saarland University Hospital, Department of Experimental Surgery, Homburg, Saar (Germany); Kim, Yoo-Jin [Saarland University Hospital, Department of Pathology, Homburg, Saar (Germany); Scheller, Bruno [Saarland University Hospital, Department of Cardiology, Homburg, Saar (Germany)

    2016-10-15

    Flow diverters are increasingly being used to treat intracranial aneurysms. This study evaluates occurring complications of flow-diverting devices in the treatment of experimental aneurysms, involving the use of micro-CT and small animal MRI at 9.4 T, in correlation to angiographic and histological findings. We previously published two preclinical studies, in which we assessed two different flow diverters in the treatment of elastase-induced aneurysms. Devices have been implanted across the aneurysm neck as well as in the abdominal aorta. From these studies, a total of 65 devices (prototype FD (n = 30) and Derivo embolization device (n = 35)) additionally underwent micro-CT and MRI after angiographic follow-up and before being histologically examined. The different architectures of both devices were precisely comparable due to high-resolution micro-CT imaging. Micro-CT revealed wire fractures in nine cases (30 %) only with the prototype FD. In three cases (10 %), severe wire fractures correlated with an in-stent stenosis due to intimal hyperplasia. Other complications, like distal stent occlusions and post-stent stenosis, were seen in both groups and verified with both imaging techniques. Osseous metaplasia were correlated to calcifications seen with micro-CT. MRI enabled visualization of the position of the implanted devices relative to the aneurysm and revealed incomplete aneurysm neck coverage with the prototype FD in two cases (6.7 %). Micro-CT and 9.4-T MRI are valid to discover and understand occurring complications of flow diverters in the preclinical phase and can serve as evaluation tools to minimize complication rates of endovascular devices in the future. (orig.)

  3. Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT

    Energy Technology Data Exchange (ETDEWEB)

    Krombach, G.A.; Schmitz-Rode, T.; Haage, P.; Guenther, R.W. [Department of Diagnostic Radiology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); DiMartino, E. [Department of Otorhinolaryngology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Prescher, A. [Department of Anatomy, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Kinzel, S. [Department of Experimental Veterinary Medicine, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany)

    2004-04-01

    We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence. (orig.)

  4. Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT

    International Nuclear Information System (INIS)

    Krombach, G.A.; Schmitz-Rode, T.; Haage, P.; Guenther, R.W.; DiMartino, E.; Prescher, A.; Kinzel, S.

    2004-01-01

    We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence. (orig.)

  5. Translation of field-reversed configurations in the FRX C/T experiment

    Energy Technology Data Exchange (ETDEWEB)

    Rej, D.J.; Armstrong, W.T.; Chrien, R.E.; Klingner, P.L.; Linford, R.K.; McKenna, K.F.; Milroy, R.D.; Sherwood, E.G.; Siemon, R.E.; Tuszewski, M.

    1984-01-01

    One of the unique features inherent to compact toroids is the potential ability to translate the plasma along its geometric axis. CT translation has proven useful in reactor design studies, and has been the focus of several experimental investigations. In this paper, we report on the initial results from translation experiments performed with the field-reversed configuration (FRC) plasmas generated in the FRX-C/T device.

  6. Translation of field-reversed configurations in the FRX C/T experiment

    International Nuclear Information System (INIS)

    Rej, D.J.; Armstrong, W.T.; Chrien, R.E.

    1984-01-01

    One of the unique features inherent to compact toroids is the potential ability to translate the plasma along its geometric axis. CT translation has proven useful in reactor design studies, and has been the focus of several experimental investigations. In this paper, we report on the initial results from translation experiments performed with the field-reversed configuration (FRC) plasmas generated in the FRX-C/T device

  7. Comprehensive imaging of tumor recurrence in breast cancer patients using whole-body MRI at 1.5 and 3 T compared to FDG-PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Gerwin P. [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany)], E-mail: gerwin.schmidt@med.uni-muenchen.de; Baur-Melnyk, Andrea [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany); Haug, Alexander [Department of Nuclear Medicine, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Heinemann, Volker [Department of Internal Medicine III, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Bauerfeind, Ingo [Department of Obstetrics and Gynecology, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Reiser, Maximilian F. [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany); Schoenberg, Stefan O. [Institute of Clinical Radiology University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg (Germany)

    2008-01-15

    Purpose: To compare the diagnostic accuracy for the detection of tumor recurrence in breast cancer patients using whole-body-MRI (WB-MRI) at 1.5 or 3 T compared to FDG-PET-CT. Materials and methods: Thirty-three female patients with breast cancer and suspicion of recurrence underwent FDG-PET-CT and WB-MRI. Coronal T1w-TSE- and STIR-sequences, HASTE-imaging of the lungs, contrast-enhanced T1w- and T2w-TSE-sequences of the liver, brain and abdomen were performed, using a WB-MRI-scanner at 1.5 (n = 23) or 3 T (n = 10). Presence of local recurrence, lymph node involvement and distant metastatic disease was assessed using clinical and radiological follow-up as a standard of reference. Results: Tumor recurrence was found in 20 of 33 patients. Overall 186 malignant foci were detected with WB-MRI and PET-CT. Both modalities revealed two recurrent tumors of the breast. PET-CT detected more lymph node metastases (n = 21) than WB-MRI (n = 16). WB-MRI was more precise in the detection of distant metastases (n = 154 versus n = 147). Sensitivity was 93% (172/186) and 91% (170/186) for WB-MRI and PET-CT, specificity was 86% (66/77) and 90% (69/77), respectively. Examination times for WB-MRI at 1.5 and 3 T were 51 and 43 min, respectively, examination time for PET-CT was 103 min. Conclusion: WB-MRI and PET-CT are useful for the detection of tumor recurrence in the follow-up of breast cancer. WB-MRI is highly sensitive to distant metastatic disease. PET-CT is more sensitive in detecting lymph node involvement. Tumor screening with WB-MRI is feasible at 1.5 and 3 T, scan time is further reduced at 3 T with identical resolution.

  8. Early clinical esophageal adenocarcinoma (cT1): Utility of CT in regional nodal metastasis detection and can the clinical accuracy be improved?

    Energy Technology Data Exchange (ETDEWEB)

    Betancourt Cuellar, Sonia L., E-mail: slbetancourt@mdanderson.org; Sabloff, Bradley, E-mail: bsabloff@mdanderson.org; Carter, Brett W., E-mail: bcarter2@mdanderson.org; Benveniste, Marcelo F., E-mail: mfbenveniste@mdanderson.org; Correa, Arlene M., E-mail: amcorrea@mdanderson.org; Maru, Dipen M., E-mail: dmaru@mdanderson.org; Ajani, Jaffer A., E-mail: jajani@mdanderson.org; Erasmus, Jeremy J., E-mail: jerasmus@mdanderson.org; Hofstetter, Wayne L., E-mail: whofstetter@mdanderson.org

    2017-03-15

    Introduction: Treatment of early esophageal cancer depends on the extent of the primary tumor and presence of regional lymph node metastasis.(RNM). Short axis diameter >10 mm is typically used to detect RNM. However, clinical determination of RNM is inaccurate and can result in inappropriate treatment. Purpose of this study is to evaluate the accuracy of a single linear measurement (short axis > 10 mm) of regional nodes on CT in predicting nodal metastasis, in patients with early esophageal cancer and whether using a mean diameter value (short axis + long axis/2) as well as nodal shape improves cN designation. Methods: CTs of 49 patients with cT1 adenocarcinoma treated with surgical resection alone were reviewed retrospectively. Regional nodes were considered positive for malignancy when round or ovoid and mean size >5 mm adjacent to the primary tumor and >7 mm when not adjacent. Results were compared with pN status after esophagectomy. Results: 18/49 patients had pN+ at resection. Using a single short axis diameter >10 mm on CT, nodal metastasis (cN) was positive in 7/49. Only 1 of these patients was pN+ at resection (sensitivity 5%, specificity 80%, accuracy 53%). Using mean size and morphologic criteria, cN was positive in 28/49. 11 of these patients were pN+ at resection (sensitivity 61%, specificity 45%, accuracy 51%). EUS with limited FNA of regional nodes resulted in 16/49 patients with pN+ being inappropriately designated as cN0. Conclusions: Evaluation of size, shape and location of regional lymph nodes on CT improves the sensitivity of cN determination compared with a short axis measurement alone in patients with cT1 esophageal cancer, although clinical utility is limited.

  9. Detectability of T Measurable diseases in advanced gastric cancer in FDG PET CT

    International Nuclear Information System (INIS)

    Oh, Sun Young; Cheon, Gi Jeong; Kim, Young Chul; Jeong, Eugene; Kim, Seung Eun; Choe, Jae Gol

    2012-01-01

    Usefulness of FDG PET CT in monitoring response in locally advanced gastric cancer has been reported. The purpose of this study was to evaluate the related factors to detect measurable diseases in advanced gastric cancer on FDG PET CT. We retrospectively reviewed 38 patients diagnosed as having advanced gastric cancer. We defined the measurable diseases when there was visualized tumor of which maximum standardized uptake value(SUVmax) was higher than 1.35*SUVmax of liver + 2*SD of liver SUV. We evaluated what kinds of factors from the clinicopathologic features were related to identifying measurable diseases. Of 38 patients with advanced gastric cancer, 18 (50%) had measurable tumors on FDG PET CT. Measurable tumors were significantly more frequent in well or moderately differentiated adenocarcinoma (70.5% vs 35.3%, p<0.05), in the tumors located at antrum or angle (66.7% vs 29.4%, p<0.05) and in the elderly group (age of 55 years old or more, 72.0% vs 8.3%, p<0.001) than the others, respectively. By multivariate analysis, age at diagnosis was the only independent predictor for the measurable disease on FDG PET CT. We found that age at diagnosis, as well as histologic types and location of tumors, were the affecting factors to detect measurable disease on FDG PET CT in patients with advanced gastric cancer. Our study suggests that elderly patients of age of 55 years old or more can frequently have T measurable disease on FDG PET CT in advanced gastric cancer and FDG PET CT will be helpful to monitor measurable disease

  10. Comprehensive Assessment of Osteoporosis and Bone Fragility with CT Colonography

    Science.gov (United States)

    Murthy, Naveen S.; Khosla, Sundeep; Clarke, Bart L.; Bruining, David H.; Kopperdahl, David L.; Lee, David C.; Keaveny, Tony M.

    2016-01-01

    Purpose To evaluate the ability of additional analysis of computed tomographic (CT) colonography images to provide a comprehensive osteoporosis assessment. Materials and Methods This Health Insurance Portability and Accountability Act–compliant study was approved by our institutional review board with a waiver of informed consent. Diagnosis of osteoporosis and assessment of fracture risk were compared between biomechanical CT analysis and dual-energy x-ray absorptiometry (DXA) in 136 women (age range, 43–92 years), each of whom underwent CT colonography and DXA within a 6-month period (between January 2008 and April 2010). Blinded to the DXA data, biomechanical CT analysis was retrospectively applied to CT images by using phantomless calibration and finite element analysis to measure bone mineral density and bone strength at the hip and spine. Regression, Bland-Altman, and reclassification analyses and paired t tests were used to compare results. Results For bone mineral density T scores at the femoral neck, biomechanical CT analysis was highly correlated (R2 = 0.84) with DXA, did not differ from DXA (P = .15, paired t test), and was able to identify osteoporosis (as defined by DXA), with 100% sensitivity in eight of eight patients (95% confidence interval [CI]: 67.6%, 100%) and 98.4% specificity in 126 of 128 patients (95% CI: 94.5%, 99.6%). Considering both the hip and spine, the classification of patients at high risk for fracture by biomechanical CT analysis—those with osteoporosis or “fragile bone strength”—agreed well against classifications for clinical osteoporosis by DXA (T score ≤−2.5 at the hip or spine), with 82.8% sensitivity in 24 of 29 patients (95% CI: 65.4%, 92.4%) and 85.7% specificity in 66 of 77 patients (95% CI: 76.2%, 91.8%). Conclusion Retrospective biomechanical CT analysis of CT colonography for colorectal cancer screening provides a comprehensive osteoporosis assessment without requiring changes in imaging protocols.

  11. DW MRI at 3.0 T versus FDG PET/CT for detection of malignant pulmonary tumors.

    Science.gov (United States)

    Zhang, Jian; Cui, Long-Biao; Tang, Xing; Ren, Xin-Ling; Shi, Jie-Ran; Yang, Hai-Nan; Zhang, Yan; Li, Zhi-Kui; Wu, Chang-Gui; Jian, Wen; Zhao, Feng; Ti, Xin-Yu; Yin, Hong

    2014-02-01

    Emerging evidence suggests that diffusion-weighted magnetic resonance imaging (DW MRI) could be useful for tumor detection with N and M staging of lung cancer in place of fluorine 18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). DW MRI at 3.0 T and FDG PET/CT were performed before therapy in 113 patients with pulmonary nodules. Mean apparent diffusion coefficient (ADC), maximal standardized uptake value (SUVmax ) and Ki-67 scores were assessed. Quantitatively, specificity and accuracy of ADC (91.7 and 92.9%, respectively) were significantly higher than those of SUVmax (66.7 and 77.9% respectively, p 0.05). Qualitatively, sensitivity, specificity and accuracy of DW MRI (96.1, 83.3 and 92.0%, respectively) were also not significantly different from that of FDG PET/CT (88.3, 83.3 and 86.7%, respectively, p > 0.05). Significant negative correlation was found between Ki-67 score and ADC (r = -0.66, p 0.05). In conclusion, quantitative and qualitative assessments for detection of malignant pulmonary tumors with DW MRI at 3.0 T are superior to those with FDG PET/CT. Furthermore, ADC could predict the malignancy of lung cancer. © 2013 UICC.

  12. C-reactive protein (+1444C>T) polymorphism influences CRP response following a moderate inflammatory stimulus.

    Science.gov (United States)

    D'Aiuto, Francesco; Casas, Juan P; Shah, Tina; Humphries, Steve E; Hingorani, Aroon D; Tonetti, Maurizio S

    2005-04-01

    Elevations in C-reactive protein (CRP) concentration are associated with an increased risk of future coronary events in prospective studies and it has been suggested that CRP could be used to aid risk prediction. A +1444C>T polymorphism in the CRP gene has been associated with differences in CRP concentration. We investigated the effect of this polymorphism on the CRP response to periodontal therapy, an intermediate inflammatory stimulus. Clinical parameters, CRP, and interleukin-6 (IL-6) concentrations were evaluated in 55 consecutive patients suffering from periodontitis at baseline, 1, 7 and 30 days after an intensive course of periodontal treatment. In a multivariate analysis individuals homozygous for the +1444T allele showed higher CRP concentrations (day 1, 21.10+/-4.81 mg/L and day 7, 4.89+/-0.74 mg/L) compared with C-allele carriers (day 1, 12.37+/-1.61 mg/L and day 7, 3.08+/-2.00 mg/L). This effect was independent of conventional cardiovascular risk factors and inflammatory factors known to affect CRP concentrations. CRP genotype may need to be considered when CRP values are used in coronary risk prediction.

  13. Association of CAT-262C/T with the concentration of catalase in seminal plasma and the risk for male infertility in Algeria.

    Science.gov (United States)

    Bousnane, Nour El Houda; May, Sadiq; Yahia, Mouloud; Abu Alhaija, Abed Alkarem

    2017-10-01

    Catalase (CAT) plays a central role in the protection of different cell types against the deleterious effects of hydrogen peroxide. In human, CAT is implicated in many physiological and pathological conditions including idiopathic male infertility. In this study we examined the association between CAT levels in seminal plasma with different sperm parameters and with CAT-262 C/T polymorphism and their risk for idiopathic male infertility in Algeria. Semen and blood samples were obtained from 111 infertile males and 104 fertile controls from the region of Eastern Algeria following informed consent. Standard semen parameters, DNA integrity, and CAT concentration in seminal plasma were evaluated. CAT-262C/T genotypes were screened using allele specific PCR. Seminal CAT activity was significantly different (pCAT activity and semen parameters (volume, motility, concentration, and morphology) were detected, but not with sperm DNA integrity. There was no direct association between CAT-262C/T polymorphism and general male infertility. However, the results presented in this study showed that CAT activity is remarkably associated with the CAT-262T allele (p=0.001) and the different CAT-262C/T genotypes. This study highlighted the major differences in the seminal plasma CAT content between infertile and fertile males and the differences of CAT concentration between different CAT-262C/T genotypes carriers.

  14. Comparison of standard and delayed imaging to improve the detection rate of [{sup 68}Ga]PSMA I and T PET/CT in patients with biochemical recurrence or prostate-specific antigen persistence after primary therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schmuck, Sebastian; Nordlohne, Stefan; Sohns, Jan M.; Ross, Tobias L.; Bengel, Frank M.; Derlin, Thorsten [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Klot, Christoph A. von [Hannover Medical School, Department of Urology and Urologic Oncology, Hannover (Germany); Henkenberens, Christoph; Christiansen, Hans [Hannover Medical School, Department of Radiation Oncology, Hannover (Germany); Wester, Hans-Juergen [Technische Universitaet Muenchen, Pharmaceutical Radiochemistry, Garching (Germany)

    2017-06-15

    The aim of this study was to assess the value of dual-time point imaging in PET/CT for detection of biochemically recurrent or persistent prostate cancer, using the prostate-specific membrane antigen (PSMA) ligand [{sup 68}Ga]PSMA I and T. 240 patients who underwent a [{sup 68}Ga]PSMA I and T PET/CT in the context of biochemical relapse of prostate cancer were included in this retrospective analysis. Imaging consisted of a standard whole-body PET/CT (1 h p.i.), followed by delayed (3 h p.i.) imaging of the abdomen. PSA-stratified proportions of positive PET/CT results, standardized uptake values and target-to-background ratios were analyzed, and compared between standard and delayed imaging. The overall detection rates of [{sup 68}Ga]PSMA I and T PET/CT were 94.2, 71.8, 58.6, 55.9 and 38.9% for PSA levels of ≥2, 1 to <2, 0.5 to <1, >0.2 to <0.5, and 0.01 to 0.2 ng/mL, respectively. Although the target-to-background ratio improved significantly over time (P < 0.0001), the majority (96.6%) of all lesions suggestive of recurrent disease could already be detected in standard imaging. Delayed imaging at 3 h p.i. exclusively identified pathologic findings in 5.4% (10/184) of abnormal [{sup 68}Ga]PSMA I and T PET/CT scans, and exclusively detected 3.4% (38/1134) of all lesions suggestive of recurrent disease. [{sup 68}Ga]PSMA I and T PET/CT shows high detection rates in patients with prostate-specific antigen persistence or biochemical recurrence of prostate cancer. Delayed imaging can detect lesions with improved contrast compared to standard imaging. However, the impact on detection rates was limited in this study. (orig.)

  15. Localized Castleman's disease: CT and MRI findings

    International Nuclear Information System (INIS)

    Chen Zuhua; Yang Guangzhao

    2008-01-01

    Objective: To study the CT and MRI findings of localized Castleman's disease (LCD). Methods: The CT (n=7) and MRI (n=2) appearance of LCD (n=7) confirmed by pathology and operation were retrospectively analyzed. Results Hyaline-vascular type(n=6) and plasma cell type (n=1) were confirmed by pathology in LCD (n=7). They were located in middle mediastinum (n=2), hilum pulmonis (n=l), posterior mediastinum (n=3), retro-peritoneum (n=1). Hyaline-vascular type focuses in CT scanning were manifested as round shape soft tissue masses, with homogeneous density, integrity envelope, distinct margin, and chaperonage arborizing and spot calcification. Marked persistent enhancement was apparent on contrast CT. MRI findings of hyaline-vascular type (n=2) was slightly isointense or hyperintense on T 1 WI, homogeneous hyperintense on T 2 WI, similar enhancement with CT after contrast. Plasma cell type focus were unhomogeneous density with abnormity necrosis, media and unhomogeneous enhancement after contrast. Conclusion: Marked persistent enhancement of LCD would be helpful to diagnosis and differential diagnosis in Castleman's disease. (authors)

  16. A review of the rates of reaction of unirradiated uranium in gaseous atmospheres

    International Nuclear Information System (INIS)

    Pearce, R.J.

    1989-10-01

    The review collates available quantitative rate data for the reaction of unirradiated uranium in dry and moist air, steam and carbon dioxide based atmospheres at temperatures ranging from room temperature to above the melting point of uranium. Reactions in nitrogen and carbon monoxide are also considered. The aim of the review is to provide a compilation of base data for the hazard analysis of fault conditions relating to Magnox fuel. (author)

  17. Review Paper: Association of Transforming Growth Factor Beta-1 -509C/T Gene Polymorphism with Ischemic Stroke: A Meta Analysis

    Directory of Open Access Journals (Sweden)

    Pradeep Kumar

    2016-05-01

    Full Text Available Introduction: Transforming Growth Factor-Beta 1 (TGF-β1 is a pleiotropic cytokine with potent anti-inflammatory property, which has been considered as an essential risk factor in the inflammatory process of Ischemic Stroke (IS, by involving in the pathophysiological progression of hypertension, atherosclerosis, and lipid metabolisms. -509C/T TGF-β1 gene polymorphism has been found to be associated with the risk of IS. The aim of this meta-analysis was to provide a relatively comprehensive account of the relation between -509C/T gene polymorphisms of TGF-β1 and susceptibility to IS. Methods: A review of literature for eligible genetic association Studies published before October 20, 2014 was conducted in the PubMed, EMBASE, Google Scholar and Trip database. The strength of association was calculated by pooled odds ratios (ORs with 95% confidence intervals using RevMan 5.3 software. Heterogeneity was examined using Higgins I-squared, Tau-squared, and Chi-squared tests. Results: A total of 2 studies involving 614 cases and 617 controls were found. The overall estimates did not show any significant relation between TGF-β1-509C/T polymorphism and risk of IS under dominant (CC+CT vs. TT: OR=1.01, 95%CI=0.31 to 3.26; P=0.99, recessive (CC vs. CT+TT: OR=0.94, 95%CI=0.47 to 1.90; P=0.87, and allelic models (T vs. C: OR=1.06, 95%CI=0.55 to 2.04; P=0.86. Conclusion: This meta-analysis showed that TGF-β1-509C/T gene polymorphism has no significant association with the susceptibility of IS. Further well-designed prospective studies with larger sample size are needed to confirm these findings.

  18. The Effect of the Degree of Luminal Contrast-Enhancement on CT Measurement of Plaque Size: A Comparison with T1-weighted Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Hur, Jin; Lee, Hye Jeong; Kim, Young Jin; Choe, Kyu Ok; Kim, Tae Hoon

    2010-01-01

    We studied early and delayed contrast-enhanced CT to determine the effects of the degree of luminal enhancement on the measurement of plaque size compared to T1-weighted MRI. T1-weighted MRI and a two-phase contrast-enhanced CT was performed in 5 New Zealand white rabbits with atherosclerosis. Early-phase images were acquired during an expected peak enhancement period of the lumen; delayed-phase images were acquired 240 sec after administration of the contrast media. Anteroposterior and lateral luminal diameters (APD, LD), luminal area (LA), total vessel area (TVA), and plaque area (PA) of the aorta were measured on MRI and CT, respectively and compared to each other. A total of 78 slices of the aorta were analyzed. PA, measured on T1-weighted MR images, was significantly greater than PA for both early-phase and delayed-phase CT (p 2 (p 2 (p 2 (p = 0.159) for MRI vs. early-phase CT, MRI vs. delayed-phase CT, and early-phase CT vs. delayed-phase CT, respectively. Different luminal densities by contrast enhancement do not affect the CT measurement of plaque area for the detection of obstructive coronary artery disease

  19. Predicting prostate cancer-specific outcome after radical prostatectomy among men with very high-risk cT3b/4 PCa: a multi-institutional outcome study of 266 patients.

    Science.gov (United States)

    Moltzahn, F; Karnes, J; Gontero, P; Kneitz, B; Tombal, B; Bader, P; Briganti, A; Montorsi, F; Van Poppel, H; Joniau, S; Spahn, M

    2015-03-01

    The value of radical prostatectomy (RP) as an approach for very high-risk prostate cancer (PCa) patients is controversial. To examine the risk of 10-year cancer-specific mortality (CSM) and other-cause mortality (OCM) according to clinical and pathological characteristics of very high-risk cT3b/4 PCa patients treated with RP as the primary treatment option. In a multi-institutional cohort, 266 patients with very high-risk cT3b/4 PCa treated with RP were identified. All patients underwent RP and pelvic lymph-node dissection. Competing-risk analyses assessed 10-year CSM and OCM before and after stratification for age and Charlson comorbidity index (CCI). Overall, 34 (13%) patients died from PCa and 73 (28%) from OCM. Ten-year CSM and OCM rates ranged from 5.6% to 12.9% and from 10% to 38%, respectively. OCM was the leading cause of death in all subgroups. Age and comorbidities were the main determinants of OCM. In healthy men, CSM rate did not differ among age groups (10-year CSM rate for ⩽64, 65-69 and ⩾70 years: 16.2%, 11.5% and 17.1%, respectively). Men with a CCI ⩾1 showed a very low risk of CSM irrespective of age (10-year CSM: 5.6-6.1%), whereas the 10-year OCM rates increased with age up to 38% in men ⩾70 years. Very high-risk cT3b/4 PCa represents a heterogeneous group. We revealed overall low CSM rates despite the highly unfavorable clinical disease. For healthy men, CSM was independent of age, supporting RP even for older men. Conversely, less healthy patients had the highest risk of dying from OCM while sharing very low risk of CSM, indicating that this group might not benefit from an aggressive surgical treatment. Outcome after RP as the primary treatment option in cT3b/4 PCa patients is related to age and comorbidity status.

  20. Anatomic study of celiac ganglia using CT in cadavers

    International Nuclear Information System (INIS)

    Zhao Qionghui; Zhang Xiaoming; Zeng Nanlin; Cai Changping; Xie Xingguo; Li Chengjun

    2005-01-01

    Objective: To identify the celiac ganglia in cadavers by using current CT techniques, and to facilitate its identification in vivo by CT. Methods: Fifty cadavers were dissected, moving peritoneal organs such as liver and stomach to expose the celiac ganglia. The location, morphology, and dimensions of celiac ganglia, and their relationship to abutting structures, were noted. The celiac ganglia in 6 of the 50 cadavers without peripancreatic diseases and with clear anatomy were isolated and marked with yellow dye and Iohexol injection. In these 6 cadavers, the moved organs were relocated, the abdomen was closed, and CT was performed. CT derived measurements of celiac ganglia were compared with those from cadavers study. Results: The celiac ganglia of 47 of 50 cadavers (94%) were located between T12-L1, and those of 3 cadavers (6%) were located between T11-12. The superior-inferior diameter of the right ganglia was (25.01 ±6.09) mm, long (left-right) diameter was (13.18 ± 3.62) mm, and short (thickness) diameter was (1.40 ± 0.55) mm. In the left ganglia, these three diameters were (22.74 ± 5.70) mm, (15.07 ± 4.35) mm, and (2.00 ± 0.71 ) mm, respectively. On the CT images of 6 cadavers, the right and left ganglia were all identified and were hyperdense relative to viscus, such as liver and spleen. The long and short diameters on CT images were (15.20 ± 1.64) mm and (1.53 ± 0.52) mm for the right ganglia and (16.25 ± 1.73 ) mm and (2.20 ± 0.73) mm for the left ganglia. There was no significant difference between the diameters of the ganglia measured on CT images and by dissection (P>0.05). Conclusion: Current CT techniques can demonstrate accurately the celiac ganglia in cadavers. This can be a reference for identifying the celiac plexus in vivo. (authors)

  1. Diagnostic accuracy of {sup 18}F-FDG PET/CT compared with that of contrast-enhanced MRI of the breast at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Magometschnigg, Heinrich F.; Baltzer, Pascal A.; Fueger, Barbara; Helbich, Thomas H.; Weber, Michael [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Vienna (Austria); Karanikas, Georgios [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Vienna (Austria); Dubsky, Peter [Medical University of Vienna, Department of Surgery, Vienna (Austria); Rudas, Margaretha [Medical University of Vienna, Department of Pathology, Vienna (Austria); Pinker, Katja [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Vienna (Austria); Molecular Imaging and Therapy Service, Memorial Sloan Kettering Cancer Center, New York (United States)

    2015-10-15

    To compare the diagnostic accuracy of prone {sup 18}F-FDG PET/CT with that of contrast-enhanced MRI (CE-MRI) at 3 T in suspicious breast lesions. To evaluate the influence of tumour size on diagnostic accuracy and the use of maximum standardized uptake value (SUV{sub MAX}) thresholds to differentiate malignant from benign breast lesions. A total of 172 consecutive patients with an imaging abnormality were included in this IRB-approved prospective study. All patients underwent {sup 18}F-FDG PET/CT and CE-MRI of the breast at 3 T in the prone position. Two reader teams independently evaluated the likelihood of malignancy as determined by {sup 18}F-FDG PET/CT and CE-MRI independently. {sup 18}F-FDG PET/CT data were qualitatively evaluated by visual interpretation. Quantitative assessment was performed by calculation of SUV{sub MAX}. Sensitivity, specificity, diagnostic accuracy, area under the curve and interreader agreement were calculated for all lesions and for lesions <10 mm. Histopathology was used as the standard of reference. There were 132 malignant and 40 benign lesions; 23 lesions (13.4 %) were <10 mm. Both {sup 18}F-FDG PET/CT and CE-MRI achieved an overall diagnostic accuracy of 93 %. There were no significant differences in sensitivity (p = 0.125), specificity (p = 0.344) or diagnostic accuracy (p = 1). For lesions <10 mm, diagnostic accuracy deteriorated to 91 % with both {sup 18}F-FDG PET/CT and CE-MRI. Although no significant difference was found for lesions <10 mm, CE-MRI at 3 T seemed to be more sensitive but less specific than {sup 18}F-FDG PET/CT. Interreader agreement was excellent (κ = 0.85 and κ = 0.92). SUV{sub MAX} threshold was not helpful in differentiating benign from malignant lesions. {sup 18}F-FDG PET/CT and CE-MRI at 3 T showed equal diagnostic accuracies in breast cancer diagnosis. For lesions <10 mm, diagnostic accuracy deteriorated, but was equal for {sup 18}F-FDG PET/CT and CE-MRI at 3 T. For lesions <10 mm, CE-MRI at 3 T seemed

  2. Induction of lethal mutations in the x-chromosome of unirradiated Drosophila oocytes after fertilization by irradiated spermatozoa

    International Nuclear Information System (INIS)

    Shaposhnikov, M.V.; Zainullin, V.G.

    2003-01-01

    Full text: In primary study on Drosophila it was found that irradiated male X-chromosomes induce recessive lethals in unirradiated female homologues (Abeleva et al., 1961, Radiobiologya. 1:123-126). The same effects were obtained in Drosophila in some recent investigations. The mechanisms of these effects is unknown. However it may be responsible for low-dose radiation effects as it induce mutations in unirradiated DNA. We assume that this effect may be a result of activation of error prone repair in response to preliminary DNA lesions in irradiated chromosome. In this research we analyse the frequencies of the recessive lethal mutations in the X-chromosome of Drosophila females mated with irradiated Basc males. We used acute irradiation with a dose rate of 10 Gy. For testing our hypothesis we use the mus209 and mei-41 mutant females. Mus209 is a PCNA gene homologue and mei-41 is a homologue of ATM gene. These genes are involved in post-replication DNA repair which may be error prone repair in Drosophila. It was obtained the tendency to decreasing the mutation rate at the mei-41[D5] background and decreasing mutation rate in mus209[B1] background in comparison with wild type strains CS (p<0.05). The obtained results demonstrate the possible role of mus209[B1] and mei-41[D5] genes in the inducing of mutations in the unirradiated X-chromosome in the presence of irradiated homologue

  3. 76 FR 14697 - Amdocs, Inc., Global Support Services, Advertising and Media AT&T Division, New Haven, CT; Notice...

    Science.gov (United States)

    2011-03-17

    ... Support Services, Advertising and Media AT&T Division, New Haven, CT; Notice of Revised Determination on... Amdocs, Inc., Global Support Services, Advertising and Media AT&T Division, New Haven, Connecticut to...: All workers of Amdocs, Inc., Global Support Services, Advertising and Media AT&T Division, New Haven...

  4. The influence of Boron on creep-rupture behaviour of austenitic unstabilized and Nb-stabilized stainless steel X8CrNi 1613 in unirradiated and irradiated condition

    International Nuclear Information System (INIS)

    Sen, Susant Kumar.

    1976-10-01

    The present study deals with influence of boron on creep-rupture behaviour in unirradiated condition at 650 0 C along with precipitation behaviour, heat-treatment and recrystallization of unstabilized and stabilized steel. The results of creep-rupture tests on unirradiated specimens show that boron exerts a beneficial effect on the rupture life and ductility. Boron losses its beneficial effect on creep properties in unstabilized steel by prolong creeping. The magnitude of beneficial effect of Boron on creep properties depends upon the initial boron distribution which influences the number, size and distribution of the precipitates. Boron promotes the precipitation of type M 23 C 6 Carbides in the grain as well as at the grain boundary. Boron segregates in atomic form during slow cooling from austenitizing temperature. The recrystallization will be delayed by the presence of boron. The results of creep tests at 650 0 C shows that boron exerts a beneficial effect on creep life of irradiated steels. (orig./GSC) [de

  5. Scintillation activity in an unirradiated single crystal of 3-hydroxyxanthine

    International Nuclear Information System (INIS)

    Cooke, D.W.; Jahan, M.S.; Alexander, C. Jr.

    1976-01-01

    A method of growing single crystals (approximately 4mm long) of 3-hydroxyxanthine is described. Observed scintillations occurring in an unirradiated single crystal of this potent oncogen as the temperature is lowered from 300 to 90 K are shown. It was found that these scintillations occur upon heating or cooling and do not diminish in activity as the number of heating and cooling cycles increase. It was found that a short duration u.v. exposure would terminate the scintillation activity and various attempts (such as annealing and pressure changes) to rejuvenate them were unsuccessful. With these observations in mind speculation is made concerning the mechanisms associated with the production of purine N-oxide derivatives. (U.K.)

  6. Accuracy of preoperative CT T staging of renal cell carcinoma: which features predict advanced stage?

    International Nuclear Information System (INIS)

    Bradley, A.J.; MacDonald, L.; Whiteside, S.; Johnson, R.J.; Ramani, V.A.C.

    2015-01-01

    Aims: To characterise CT findings in renal cell carcinoma (RCC), and establish which features are associated with higher clinical T stage disease, and to evaluate patterns of discrepancy between radiological and pathological staging of RCC. Materials and methods: Preoperative CT studies of 92 patients with 94 pathologically proven RCCs were retrospectively reviewed. CT stage was compared with pathological stage using the American Joint Committee on Cancer (AJCC), 7 th edition (2010). The presence or absence of tumour necrosis, perinephric fat standing, thickening of Gerota's fascia, collateral vessels were noted, and correlated with pT stage. The sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) for predicting pT stage ≥pT3a were derived separately for different predictors using cross-tabulations. Results: Twenty-four lesions were pathological stage T1a, 21 were T1b, seven were T2a, 25 were T3a, 11 were T3b, four were T3c, and two were T4. There were no stage T2b. Sixty-three (67%) patients had necrosis, 27 (29%) thickening of Gerota's fascia (1 T1a), 25 had collateral vessels (0 T1a), 28 (30%) had fat stranding of <2 mm, 20 (21%) of 2–5mm and one (1%) of >5 mm. For pT stage ≥pT3a, the presence of perinephric fat stranding had a sensitivity, specificity, PPV and NPV of 74%, 65%, 63%, and 76%, respectively. Presence of tumour necrosis had a sensitivity, specificity, PPV, and NPV of 81%, 44%, 54%, and 72%, respectively. Thickening of Gerota's fascia had a sensitivity, specificity, PPV, and NPV of 52%, 90%, 81% and 70%, respectively; and enlarged collateral vessels had a sensitivity, specificity, PPV, and NPV value of 52%, 94%, 88%, and 71% respectively. Conclusion: The presence of perinephric stranding and tumour necrosis were not reliable signs for pT stage >T3a. Thickening of Gerota's fascia and the presence of collateral vessels in the peri- or paranephric fat had 90% and 94% specificity, with 82% and 88

  7. Thermogravimetric studies of the thermo-oxidative stability of irradiated and unirradiated polyethylene. 2. Combined antioxidants

    Energy Technology Data Exchange (ETDEWEB)

    Novakovic, L; Gal, O; Markovic, V; Stannett, V T

    1985-01-01

    In part one of this series the effects of a phenolic, an amine and a thioester antioxidant on the thermo-oxidative stability of irradiated and unirradiated low-density polyethylene was reported. In this paper the effects of combined phenolic and thioester stabilizers are described. Isothermal thermogravimetric analysis was used to study the systems. Pronounced synergism was observed with the induction periods, the time when the initial weight loss begins and the 5% weight loss. At about 50% of each stabilizer increases greater than twofold were observed both with the unirradiated and irradiated polymers. The rate constants for oxygen uptake were decreased. However, the rates of degradation at 5% weight loss fell between the values of the two pure stabilizers with no pronounced synergism in either case. In the absence of oxygen little effect of either antioxidant or their mixtures was observed. The corresponding activation energies were somewhat higher, however, with the irradiated samples containing antioxidants. Dynamic thermogravimetry was used for this study. A kinetic analysis indicated that there were somewhat different modes of degradation at lower- and higher-temperature ranges. (author).

  8. Histochemical differentiation between unirradiated and gamma-irradiated tissue in commercial use of some irradiated vegetables

    International Nuclear Information System (INIS)

    Foa, E.

    1978-01-01

    The use of gamma irradiation as a commercial method for the preservation of fruits and vegetables calls for methods of differentiation between unirradiated and irradiated products. A new approach to studying the influence of gamma irradiation on vegetable tissue at the cellular level by histochemical techniques has been developed by the authors and already applied to a number of fruits and vegetables. The possibility of evidencing radiation effects in the polysaccharide components of the cell wall suggested that these detected differences could be applied to differentiate irradiated from unirradiated tomatoes and potatoes. Some work done to determine changes in the cell wall polysaccharides of gamma-irradiated potatoes and tomatoes and to relate these changes to some other factors, such as storage time and vegetable variety, is reported here. While significant differences have been found in the optical densities of the total polysaccharides of the cell wall as a function of irradiation and of the other variables mentioned, it is not yet possible to use these values as a means of reliable differentiation. (author)

  9. c.1810C>T Polymorphism of NTRK1 Gene is associated with reduced Survival in Neuroblastoma Patients

    International Nuclear Information System (INIS)

    Lipska, Beata S; Biernat, Wojciech; Limon, Janusz; Drożynska, Elżbieta; Scaruffi, Paola; Tonini, Gian Paolo; Iżycka-Świeszewska, Ewa; Ziętkiewicz, Szymon; Balcerska, Anna; Perek, Danuta; Chybicka, Alicja

    2009-01-01

    TrkA (encoded by NTRK1 gene), the high-affinity tyrosine kinase receptor for neurotrophins, is involved in neural crest cell differentiation. Its expression has been reported to be associated with a favourable prognosis in neuroblastoma. Therefore, the entire coding sequence of NTRK1 gene has been analysed in order to identify mutations and/or polymorphisms which may alter TrkA receptor expression. DNA was extracted from neuroblastomas of 55 Polish and 114 Italian patients and from peripheral blood leukocytes of 158 healthy controls. Denaturing High-Performance Liquid Chromatography (DHPLC) and Single-Strand Conformation Polymorphism (SSCP) analysis were used to screen for sequence variants. Genetic changes were confirmed by direct sequencing and correlated with biological and clinical data. Three previously reported and nine new single nucleotide polymorphisms were detected. c.1810C>T polymorphism present in 8.7% of cases was found to be an independent marker of disease recurrence (OR = 13.3; p = 0.009) associated with lower survival rates (HR = 4.45 p = 0.041). c.1810C>T polymorphism's unfavourable prognostic value was most significant in patients under 18 months of age with no MYCN amplification (HR = 26; p = 0.008). In-silico analysis of the c.1810C>T polymorphism suggests that the substitution of the corresponding amino acid residue within the conservative region of the tyrosine kinase domain might theoretically interfere with the functioning of the TrkA protein. NTRK1 c.1810C>T polymorphism appears to be a new independent prognostic factor of poor outcome in neuroblastoma, especially in children under 18 months of age with no MYCN amplification

  10. Application of CT perfusion imaging in radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Xia Guangrong; Liu Guimei; He Wen; Jin Guohua; Xie Ruming; Xu Yongxiang; Li Xiaobo; Li Xuebing

    2011-01-01

    Objective: To investigate the value of CT perfusion imaging in evaluation of therapeutic effect and prognosis in radiotherapy for lung cancer. Methods: Fifty-one cases of lung cancer who were unable or refused to be operated on, 36 males and 15 females, aged 37-80, underwent CT perfusion imaging, 29 of which only before radiotherapy and 22 before and after radiotherapy twice. The images were collected by cine dynamic scanning (5 mm/4 slices) and input into the GE AW4.0 workstation for data processing. The slice positions of CT imaging were determined according to the largest tumor size in CT scan. Regions of interest of tumor were drawn at the region corresponding to the original images of CT perfusion. Radiotherapy was performed after CT perfusion imaging. Relevant parameters, including blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface (PS) were calculated. The treatment response after radiotherapy was evaluated by RECIST. At 2 -4 weeks after the treatment, CT examination was conducted once more. Results: The tests of the 51 patients showed that the BV was 13.6 ml·100 g -1 , the BF was 129.5 ml·min -1 ·100 g -1 , the MTT was 9.1 s, and the PS was 10.0 ml· min -1 · 100 g -1 before radiotherapy. The tests of the 22 of the 51 patients showed that the values of BV and BF after radiotherapy were 7.6 ml· 100 g -1 and 97.8 ml·min -1 · 100 g -1 , respectively, both lower than those before radiotherapy (11.2 and 108.7 ml·min -1 ·100 g -1 , respectively), however, both not significantly (t=1.28, 0.40, P>0.05); and the values of MTT and PS after radiotherapy were 8.9 s and 7.8 ml·min -1 · 100 g -1 , respectively, both not significantly higher than those before radiotherapy (7.2 s and 6.8 ml· min -1 · 100 g -1 , respectively, t=-1.15, -0.57, P>0.05). The mean area of tumor after radiotherapy was 1189.6 mm 2 , significantly less than that before radiotherapy (1920.3 mm 2 , t=3.98, P<0.05). The MTT of the SCLC patients was 12

  11. The extensor carpi ulnaris pseudolesion: evaluation with microCT, histology, and MRI

    International Nuclear Information System (INIS)

    Ali, Sayed; Cunningham, Ryan; Mohamed, Feroze; Amin, Mamta; Popoff, Steven N.; Barbe, Mary F.

    2015-01-01

    To determine if magic angle plays a role in apparent central increased signal intensity of the distal extensor carpi ulnaris tendon (ECU) on MRI, to see if histologic findings of tendon degeneration are associated with increased T1 or T2 tendon signal on MR imaging, and to determine the prevalence of the ECU ''pseudolesion''. A standard 3 Tesla protocol was utilized to scan ten cadaveric wrists. A 40 mm length of 10 ECU and four extensor carpi radialis brevis (ECRB) tendons were immersion fixed before microCT scanning. Staining with Alcian blue, Masson's trichrome and Safranin O was performed before light microscopy. Fifty clinical wrist MRIs were also reviewed for the presence of increased T1 and/or T2 signal. Central increased T1 and/or T2 signal was observed in 9 of 10 cadaveric ECU tendons, but not in ECRB tendons. MicroCT and histology showed inter-tendinous matrix between the two distal heads of the ECU. Increased mucoid degeneration correlated with increased MRI signal intensity. The tendon fibers were at a maximum of 8.39 to the longitudinal axis on microCT. Clinical MRIs showed increased T1 signal in 6 %, increased T2 signal in 8 %, increased T1 and T2 signal in 80 %, and 6 % showing no increased signal. Central increased T1 and/or T2 signal in the ECU tendon indicates the presence of normal inter-tendinous ground substance, with increased proteoglycan content (mucoid degeneration) responsible for increased signal intensity. None of the fibers were shown on microCT to approach the magic angle. (orig.)

  12. The extensor carpi ulnaris pseudolesion: evaluation with microCT, histology, and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Sayed; Cunningham, Ryan; Mohamed, Feroze [Temple University Hospital, Department of Radiology, Philadelphia, PA (United States); Amin, Mamta; Popoff, Steven N.; Barbe, Mary F. [Temple University School of Medicine, Department of Anatomy, Philadelphia, PA (United States)

    2015-12-15

    To determine if magic angle plays a role in apparent central increased signal intensity of the distal extensor carpi ulnaris tendon (ECU) on MRI, to see if histologic findings of tendon degeneration are associated with increased T1 or T2 tendon signal on MR imaging, and to determine the prevalence of the ECU ''pseudolesion''. A standard 3 Tesla protocol was utilized to scan ten cadaveric wrists. A 40 mm length of 10 ECU and four extensor carpi radialis brevis (ECRB) tendons were immersion fixed before microCT scanning. Staining with Alcian blue, Masson's trichrome and Safranin O was performed before light microscopy. Fifty clinical wrist MRIs were also reviewed for the presence of increased T1 and/or T2 signal. Central increased T1 and/or T2 signal was observed in 9 of 10 cadaveric ECU tendons, but not in ECRB tendons. MicroCT and histology showed inter-tendinous matrix between the two distal heads of the ECU. Increased mucoid degeneration correlated with increased MRI signal intensity. The tendon fibers were at a maximum of 8.39 to the longitudinal axis on microCT. Clinical MRIs showed increased T1 signal in 6 %, increased T2 signal in 8 %, increased T1 and T2 signal in 80 %, and 6 % showing no increased signal. Central increased T1 and/or T2 signal in the ECU tendon indicates the presence of normal inter-tendinous ground substance, with increased proteoglycan content (mucoid degeneration) responsible for increased signal intensity. None of the fibers were shown on microCT to approach the magic angle. (orig.)

  13. Correlation between the -1562C/T polymorphism in the matrix metalloproteinase-9 gene and hemorrhagic transformation of ischemic stroke.

    Science.gov (United States)

    Zhang, Xiaoman; Cao, Xinhui; Xu, Xiaoyu; Li, Aifan; Xu, Yuming

    2015-03-01

    The aim of the present study was to investigate the correlation between the -1562C/T polymorphism in an intron of the matrix metalloproteinase-9 (MMP-9) gene and hemorrhagic transformation of ischemic stroke (IS). Using polymerase chain reaction-restriction fragment length polymorphism, the -1562C/T polymorphisms in 222 patients with IS were detected. The patients were divided into hemorrhagic transformation (HT; 84 cases) and non-hemorrhagic transformation (NHT) groups (138 cases) depending on the results from the susceptibility-weighted magnetic resonance imaging, which was performed between one and two weeks following stroke onset. The allele frequencies were subsequently compared. Baseline data of the two groups were comparable. The HT group exhibited a significantly lower frequency of the CT+TT genotype compared with the NHT group (17.86 vs. 30.43%, Pcorrelated with hemorrhagic transformation of IS in the population studied. Furthermore, the T allele may be a protective factor for hemorrhagic transformation of IS in this population.

  14. A genome-wide SNP-association study confirms a sequence variant (g.66493737C>T in the equine myostatin (MSTN gene as the most powerful predictor of optimum racing distance for Thoroughbred racehorses

    Directory of Open Access Journals (Sweden)

    Whiston Ronan

    2010-10-01

    Full Text Available Abstract Background Thoroughbred horses have been selected for traits contributing to speed and stamina for centuries. It is widely recognized that inherited variation in physical and physiological characteristics is responsible for variation in individual aptitude for race distance, and that muscle phenotypes in particular are important. Results A genome-wide SNP-association study for optimum racing distance was performed using the EquineSNP50 Bead Chip genotyping array in a cohort of n = 118 elite Thoroughbred racehorses divergent for race distance aptitude. In a cohort-based association test we evaluated genotypic variation at 40,977 SNPs between horses suited to short distance (≤ 8 f and middle-long distance (> 8 f races. The most significant SNP was located on chromosome 18: BIEC2-417495 ~690 kb from the gene encoding myostatin (MSTN [Punadj. = 6.96 × 10-6]. Considering best race distance as a quantitative phenotype, a peak of association on chromosome 18 (chr18:65809482-67545806 comprising eight SNPs encompassing a 1.7 Mb region was observed. Again, similar to the cohort-based analysis, the most significant SNP was BIEC2-417495 (Punadj. = 1.61 × 10-9; PBonf. = 6.58 × 10-5. In a candidate gene study we have previously reported a SNP (g.66493737C>T in MSTN associated with best race distance in Thoroughbreds; however, its functional and genome-wide relevance were uncertain. Additional re-sequencing in the flanking regions of the MSTN gene revealed four novel 3' UTR SNPs and a 227 bp SINE insertion polymorphism in the 5' UTR promoter sequence. Linkage disequilibrium was highest between g.66493737C>T and BIEC2-417495 (r2 = 0.86. Conclusions Comparative association tests consistently demonstrated the g.66493737C>T SNP as the superior variant in the prediction of distance aptitude in racehorses (g.66493737C>T, P = 1.02 × 10-10; BIEC2-417495, Punadj. = 1.61 × 10-9. Functional investigations will be required to determine whether this

  15. Polycystic ovary syndrome: association of a C/T single nucleotide polymorphism at tyrosine kinase domain of insulin receptor gene with pathogenesis among lean Japanese women.

    Science.gov (United States)

    Kashima, Katsunori; Yahata, Tetsuro; Fujita, Kazuyuki; Tanaka, Kenichi

    2013-01-01

    To assess whether the insulin receptor (INSR) gene contributes to genetic susceptibility to polycystic ovary syndrome (PCOS) in a Japanese population. We ex-amined the frequency of the His 1058 C/T single nucleotide polymorphism (SNP) found in exon 17 of the INSR gene in 61 Japanese PCOS patients and 99 Japanese healthy controls. In addition, we analyzed the association between the genotype of this SNP and the clinical phenotypes. The frequency of the C/C genotype was not significantly different between all PCOS patients (47.5%) and controls (35.4%). However, among the lean cases (body mass index PCOS patients (65.0%) as compared with controls (36.6%). We concluded that the His 1058 C/T polymorphism at the tyrosine kinase domain of the INSR gene had a relationship to the pathogenesis of lean PCOS patients in a Japanese population.

  16. Evaluation of tumor invasion in gastric carcinoma with CT using water as an oral contrast agent in prone position

    International Nuclear Information System (INIS)

    Chung, Jin Il; Lee, Jong Tae; Yoo, Hyung Sik; Lee, Byung Hee; Bae, Jong Yup

    1994-01-01

    To evaluate the accuracy of CT using water as an oral contrast material in a prone position in determining the depth of tumor invasion in gastric cancer patients. Thirty three patients(19 male, 14 female) with surgically confirmed gastric cancer were studied. We performed CT in a prone position after ingestion of 1 liter of pure water. CT findings were classified into 4 groups by the morphologic appearance of infiltrates in the perigastric fat plane: normal perigastric fat(S0), fine mottled densities(S1), irregular aggregated or liner densities(S2) and direct extension and invasion of tumor into contiguous structures(S3). Also we prospectively compared the CT staging with pathologic T staging according to the TNM systems. The overall accuracy of CT staging in determining the pathologic T factor was 69.6%. As we regarded T1 and T2 lesions as one group on CT, the accuracy of CT staging was increased to 80.2% because of a limitation of CT for distinguishing T1 from T2 lesions. Prone position CT using water as an oral contrast agent is quite accurate in determining the T staging of gastric carcinoma

  17. Truck accident involving unirradiated nuclear fuel

    International Nuclear Information System (INIS)

    Carlson, R.W.; Fischer, L.E.

    1993-01-01

    In the early morning of Dec. 16, 1991, a severe accident occurred when a passenger vehicle traveling in the wrong direction collided with a tractor trailer carrying 24 unirradiated nuclear fuel assemblies in 12 containers on Interstate I-91 in Springfield, Massachusetts. This paper documents the mechanical circumstances of the accident and assesses the physical environment to which the containers were exposed and the response of the containers and their contents. The accident involved four impacts where the truck was struck by the car, impacted on the center guardrail, impacted on the outer concrete barrier and came to rest against the center guardrail. The impacts were followed by a fire that began in the engine compartment, spread to the tractor and cab, and eventually spread to the trailer and payload. The fire lasted for about three hours and the packages were involved in the fire for about two hours. As a result of the fire, the tractor-trailer was completely destroyed and the packages were exposed to flames with temperatures between 1,300 F and 1,800 F. The fuel assemblies remained intact during the accident and there was no release of any radioactive material during the accident. This was a very severe accident; however, the injuries were minor and at no time was the public health and safety at risk

  18. Preoperative assessment of gastric artery in patients with gastric cancer by CT angiography on 64-slice spiral CT

    International Nuclear Information System (INIS)

    Tang Lei; Zhang Xiaopeng; Sun Yingshi; Cao Kun; Qi Liping; Cui Yong; Wang Ning

    2010-01-01

    Objective: To evaluate the efficacy of different three-dimensional CTA methods on 64-slice sprial CT in the preoperative assessment of gastric arteries and their variations. Methods: Sixty-six consecutive patients with gastric cancer who underwent 64-slice spiral CT examinations preoperatively were retrospectively studied. To get the STS-MIP images, the thickness of slab was adjusted according to the inner diameter of targeted blood vessels and their cross-layer distribution. After four weeks, the AVVR images of all cases was got by the auto-vessel technique. The demonstration rates and origins of the direct and indirect feeding arteries were analyzed on AVVR and STS-MIP. McNemar tests were used to compare the detection rates of gastric feeding arteries by STS-MIP and AVVR. The relationship between CT value and display rate of vessels was analyzed using independent-samples t test. The variations of blood vessels were analyzed. Results: The display rate of indirect feeding arteries were all 100% (66/66) by STS-MIP and AVVR. The display rates of left gastric artery (LGA) and right gastroepiploic artery (RGEA) were 98.5% (65/66), 100.0% (66/66) and 97.0% (64/66), 100.0% (66/66) by STS-MIP and AVVR respectively. The display rates of right artery (RGA), left gastroepiploic artery (LGEA), short gastric artery (SGA) and posterior gastric artery (RGA), left gastroepiploic artery (LGEA), short gastric artery (SGA) and posterior gastric artery (PGA) by AVVR were lower than those of STS-MIP with statistical significances [RGA: 68.2% (45/66) vs. 98.5% (65/66), P<0.01; LGEA: 53.0% (35/66) vs. 97.0% (64/66), P<0.01; SGA: 7.6%(5/66) vs. 59.1% (39/66), P<0.01; PGA: 18.2% (12/66) vs. 63.6% (42/66), P<0.01]. The demonstration rates of LGEA, RGEA and SGA increased accompanied with the increasing of CT value in celiac axis (LGEA: 35 cases displayed with mean CT value of (272 ± 44) HU, 31 cases did not display with mean CT value of (229 ± 42) HU, t=4.043, P<0.01; RGEA: 64 cases

  19. Utility of early dynamic and delayed post-diuretic 18F-FDG PET/CT SUVmax in predicting tumour grade and T-stage of urinary bladder carcinoma: results from a prospective single centre study.

    Science.gov (United States)

    Sharma, Abhishek; Mete, Uttam K; Sood, Ashwani; Kakkar, Nandita; Gorla, Arun K R; Mittal, Bhagwant R

    2017-04-01

    Accurate pre-treatment grading and staging of bladder cancer are vital for better therapeutic decision and prognosis. The aim of the present study was to evaluate the correlation between maximum standardized uptake value (SUV max ) calculated during early dynamic and post-diuretic fluorine-18 fludeoxyglucose ( 18 F-FDG) positron emission tomography (PET)/CT studies with grade and pT-stage of bladder cancer. 39 patients with suspected/proven bladder carcinoma underwent 10-min early dynamic pelvic imaging and delayed post-diuretic whole-body FDG PET/CT imaging. SUV max of the lesions derived from both studies was compared with grade and pT-stage. Relationship of SUV max with grade and pT-stage was analyzed using independent sample t-test and analysis of variance. SUV max of the early dynamic imaging showing tumour perfusion was independent from the SUV max of delayed imaging. High-grade tumours showed higher SUV max than low-grade tumours in the early dynamic imaging (5.4 ± 1.4 vs 4.7 ± 1.6; p-value 0.144) with statistically significant higher value in Stage pT1 tumours (6.8 ± 0.8 vs 5.5 ± 1.2; p-value 0.04). Non-invasive pTa tumours had significantly less SUV max than higher stage tumours during early dynamic imaging [F(4,29) = 6.860, p 0.001]. Early dynamic imaging may have a role in predicting the grade and aggressiveness of the bladder tumours and thus can help in treatment planning and prognostication. Advances in knowledge: Dynamic PET/CT is a limitedly explored imaging technique. This prospective pilot study demonstrates the utility of this modality as a potential adjunct to standard FDG PET/CT imaging in predicting the grade and aggressiveness of the bladder tumours and thus can impact the patient management.

  20. Comparison of CT during arterial portography, delayed iodine CT, and MR imaging for the preoperative evaluation of hepatic tumors

    International Nuclear Information System (INIS)

    Nelson, R.C.; Chezmar, J.L.; Sugarbaker, P.H.; Bernardino, M.E.

    1988-01-01

    Twenty-eight patients with neoplastic involvement of the liver were studied with CT during arterial portography, delayed iodine CT, and MR imaging, to determine the number, size, and location of focal hepatic lesions prior to hepatic tumor surgery. The MR pulse-sequences used included T1- and T2-weighted spin-echo (SE) sequences and inversion-recovery (IR) sequences at 0.5 T, 1.5 T, or both. Results were compared with operative and pathologic findings. The sensitivities for the detection of individual focal lesions are as follows: CT during arterial portography, delayed iodine CT, 77%, IR at 0.5 T, 74%; T1-weighted SE at 0.5 T, 69%; T2-weighted SE at 1.5 T, 55%, IR at 1.5 T, 50%; T2-weighted SE at 0.5 T, 48%, and T1-weighted SE at 1.5 T, 31%. The positive predictive values ranged from 88% to 100% for all techniques. The authors' data suggest that CT during arterial portography is a superior technique for evaluating patients prior to hepatic tumor surgery

  1. Mechanisms of the p(He 6,He 5)d, p(He 6,α)t and p(He 6,t)α reactions

    International Nuclear Information System (INIS)

    Heiberg-Andersen, Henning

    2002-07-01

    This work was devoted to nucleon induced transfer reactions having the potential to probe the sub-cluster structures of the benchmark halo nucleus He 6, without the question marks the necessarily omitted exchange effects tend to put behind the CRC results when both collision partners are composite systems. Still, the exchange complications entered the analysis in an ironic way: The high Q-value of the p(He 6,α)t and p(He 6, t)α reactions caused sensitivity to the t - α optical potential at small radii, where the one-nucleon exchange effects are strongest. Since the attempt to throw them out of the extracted tau - α potential failed, it was necessary to extend the model space to avoid a too difficult modelling of the local equivalent t - α potential. By this step, all the complications originating from antisymmetrization within a larger model space entered the analysis. However, the persistent failures of the two-channel calculations of this and previous works can hardly be due to incorrect treatment of exchange effects only, so the loss of simplicity is probably illusory. Even at small angles, where the surface processes dominate, none of the two-channel calculations with various choices of t - α optical potentials managed to reproduce the p(He 6, α)t (p(He 6,t)α) data. This motivated inclusion of sequential transfers through the d + He 5 channel, where the sequential triton transfer process, included just for consistency in the coupling scheme of the four-channel calculation, turned out to be more influent than expected. The satisfactory reproduction of both the p(He 6, He 5)d and the p(He 6,α)t (p(He 6,t)α) data by the four-channel approach and the required re-normalization the real part of the p - He 6 optical potential are strong indications of substantial contributions from sequential transfer of the halo neutrons at this energy. The conclusions that can be drawn from this work are limited by the modest amount of available data. This limitation does

  2. Mechanisms of the p(He 6,He 5)d, p(He 6,{alpha})t and p(He 6,t){alpha} reactions

    Energy Technology Data Exchange (ETDEWEB)

    Heiberg-Andersen, Henning

    2002-07-01

    This work was devoted to nucleon induced transfer reactions having the potential to probe the sub-cluster structures of the benchmark halo nucleus He 6, without the question marks the necessarily omitted exchange effects tend to put behind the CRC results when both collision partners are composite systems. Still, the exchange complications entered the analysis in an ironic way: The high Q-value of the p(He 6,{alpha})t and p(He 6, t){alpha} reactions caused sensitivity to the t - {alpha} optical potential at small radii, where the one-nucleon exchange effects are strongest. Since the attempt to throw them out of the extracted tau - {alpha} potential failed, it was necessary to extend the model space to avoid a too difficult modelling of the local equivalent t - {alpha} potential. By this step, all the complications originating from antisymmetrization within a larger model space entered the analysis. However, the persistent failures of the two-channel calculations of this and previous works can hardly be due to incorrect treatment of exchange effects only, so the loss of simplicity is probably illusory. Even at small angles, where the surface processes dominate, none of the two-channel calculations with various choices of t - {alpha} optical potentials managed to reproduce the p(He 6, {alpha})t (p(He 6,t){alpha}) data. This motivated inclusion of sequential transfers through the d + He 5 channel, where the sequential triton transfer process, included just for consistency in the coupling scheme of the four-channel calculation, turned out to be more influent than expected. The satisfactory reproduction of both the p(He 6, He 5)d and the p(He 6,{alpha})t (p(He 6,t){alpha}) data by the four-channel approach and the required re-normalization the real part of the p - He 6 optical potential are strong indications of substantial contributions from sequential transfer of the halo neutrons at this energy. The conclusions that can be drawn from this work are limited by the

  3. Breakeven analysis of computed tomography (Based on utilization of whole body C.T. scanner of SNU hospital)

    International Nuclear Information System (INIS)

    Cheung, Hwan; Choi, Myung Jun; Yoo, Chang Ho

    1986-01-01

    The C.T. scanner, an important tool for image-based diagnostics, is one of the costliest types of medical equipment. At present, there are in Korea a total of 66 units installed, and more units will be added in the future. For the fact the price of the C.T. scanner as well as scanning charge for using the equipment is very high as compared to those of the other kinds of medical equipment. The break-even analysis of computed tomography is considered fundamental as well as essential both to rational hospital management and keeping the charge for its use at an optimum level in consideration of the patient's medical expense burden. Even if pursuit of profits is not the role objective of a hospital, it cannot be denied that a break-even analysis provides an important factor for the decision making process in hospital management. The present study has the purpose of finding the ways and means to help rationalize hospital operation and improve its earning power through break-even analysis of C.T. scanner operation. For this purpose the total cost of the GE 8800 Whole Body C. T. Scanner installed at the Seoul National University Hospital was computed, and the records of its operation were analyzed. The expenses for its operation were divided into direct and indirect expenses depending on whether generation of the cost was recognized in the C. T. room or not, and the actual cost was computed for each of these accounting units

  4. Genetic variability of the inflammatory response. I. The -511 C/T IL1β polymorphism in different Peruvian subpopulations

    OpenAIRE

    Acosta, Oscar; Solano, Luis; Huerta, Doris; Oré, Daniel; Sandoval, José; Figueroa, José; Fujita, Ricardo

    2012-01-01

    El polimorfismo -511 citosina/timina (-511 C/T) en la región promotora del gen interleuquina 1 beta (IL1β) está implicado en la producción diferencial de la citoquina y por tanto puede estar asociado a la respuesta inmuno-inflamatoria en obesidad, dislipidemias, cardiopatías, cáncer, infecciones, y el tratamiento con nutrientes y fármacos. Objetivos: Establecer la distribución de frecuencias de los genotipos y alelos del polimorfismo -511 C/T del gen IL1β en diferentes subpoblaciones peruanas...

  5. Deep embedding convolutional neural network for synthesizing CT image from T1-Weighted MR image.

    Science.gov (United States)

    Xiang, Lei; Wang, Qian; Nie, Dong; Zhang, Lichi; Jin, Xiyao; Qiao, Yu; Shen, Dinggang

    2018-07-01

    Recently, more and more attention is drawn to the field of medical image synthesis across modalities. Among them, the synthesis of computed tomography (CT) image from T1-weighted magnetic resonance (MR) image is of great importance, although the mapping between them is highly complex due to large gaps of appearances of the two modalities. In this work, we aim to tackle this MR-to-CT synthesis task by a novel deep embedding convolutional neural network (DECNN). Specifically, we generate the feature maps from MR images, and then transform these feature maps forward through convolutional layers in the network. We can further compute a tentative CT synthesis from the midway of the flow of feature maps, and then embed this tentative CT synthesis result back to the feature maps. This embedding operation results in better feature maps, which are further transformed forward in DECNN. After repeating this embedding procedure for several times in the network, we can eventually synthesize a final CT image in the end of the DECNN. We have validated our proposed method on both brain and prostate imaging datasets, by also comparing with the state-of-the-art methods. Experimental results suggest that our DECNN (with repeated embedding operations) demonstrates its superior performances, in terms of both the perceptive quality of the synthesized CT image and the run-time cost for synthesizing a CT image. Copyright © 2018. Published by Elsevier B.V.

  6. CT colonography combined with fistulography - a case of periannal fistula of a 6 months old child

    International Nuclear Information System (INIS)

    Sirakov, N.; Velkova, K.; Sirakov, V.; Tashev, P.

    2007-01-01

    We present a 6 months old child with perianal fistula with repeated secretion from it. The child was examined by double contrast barium enema and transrectal ultrasonography that gave suggestions of perianal fistula with no communication to the rectum and suspicion of a anal duplication of the rectum. The child was examined by CT colonography combined with fistulography. The exam was carried out on a axial CT Somatom Emotion by Siemens. The purpose of our report is to present the results of the combination of CT colonography and fistulography, applied to a 6-month-old child, as well as to present the specific protocol that we used for this examination. (authors)

  7. CT-guided radiofrequency ablation of T1a renal cell carcinma in Korea; Mid-erm outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hae Jin; Park, Byung Kwan; Park, Jung Jae; Kim, Chan Kyo [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-09-15

    To evaluate the mid-term outcomes of percutaneous radiofrequency ablation (RFA) treatment in patients with small (< 4 cm) renal cell carcinoma (RCC) in Korea. Between 2010 and 2015, 51 patients (40 men and 11 women; median age, 57 years) with biopsyproven 51 RCC were treated using CT-guided RFA. All patients were clinically staged T1aN0M0 prior to RFA. The median tumor size and follow-up period were 2.1 cm (range, 1.0–3.9 cm) and 26 months (4–60 months), respectively. Local tumor progression, distant metastasis, primary and secondary effectiveness rates, and major complication rates were recorded. Estimated glomerular filtration rates (GFRs) between pre-RFA and last follow-up were compared using paired t tests. The 2-year recurrence-free survival rate was calculated using Kaplan-Meier survival analysis. Of the 51 patients, 2 (3.9%) experienced local tumor progression, and 1 (2.0%) had lymph node metastasis after the first RFA session. Primary and secondary effectiveness rates were 96.1% (49/51) and 100% (1/1), respectively. Only 1 patient experienced a major complication (uretero-pelvic stricture) after the second RFA session for treating a local tumor progression, and the major complication rate was 1.9% (1/52). The median pre-RFA and last follow-up GFRs were 87.1 mL/ min/1.73 m{sup 2} (14.2–142.7 mL/min/1.73 m{sup 2}) and 72.0 mL/min/1.73 m{sup 2} (7.2–112.6 mL/min/1.73 m{sup 2}), respectively (p < 0.0001). The 2-year recurrence-free survival rate was 96.0%. CT-guided RFA is a safe and effective treatment in Korean patients with T1a RCC because of excellent mid-term outcomes.

  8. CT-Guided Radiofrequency Ablation of T1a Renal Cell Carcinoma in Korea: Mid-Term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hae Jin; Park, Byung Kwan; Park, Jung Jae; Kim, Chan Kyo [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351 (Korea, Republic of)

    2016-11-01

    To evaluate the mid-term outcomes of percutaneous radiofrequency ablation (RFA) treatment in patients with small (< 4 cm) renal cell carcinoma (RCC) in Korea. Between 2010 and 2015, 51 patients (40 men and 11 women; median age, 57 years) with biopsyproven 51 RCC were treated using CT-guided RFA. All patients were clinically staged T1aN0M0 prior to RFA. The median tumor size and follow-up period were 2.1 cm (range, 1.0–3.9 cm) and 26 months (4–60 months), respectively. Local tumor progression, distant metastasis, primary and secondary effectiveness rates, and major complication rates were recorded. Estimated glomerular filtration rates (GFRs) between pre-RFA and last follow-up were compared using paired t tests. The 2-year recurrence-free survival rate was calculated using Kaplan-Meier survival analysis. Of the 51 patients, 2 (3.9%) experienced local tumor progression, and 1 (2.0%) had lymph node metastasis after the first RFA session. Primary and secondary effectiveness rates were 96.1% (49/51) and 100% (1/1), respectively. Only 1 patient experienced a major complication (uretero-pelvic stricture) after the second RFA session for treating a local tumor progression, and the major complication rate was 1.9% (1/52). The median pre-RFA and last follow-up GFRs were 87.1 mL/ min/1.73 m{sup 2} (14.2–142.7 mL/min/1.73 m{sup 2}) and 72.0 mL/min/1.73 m{sup 2} (7.2–112.6 mL/min/1.73 m{sup 2}), respectively (p < 0.0001). The 2-year recurrence-free survival rate was 96.0%. CT-guided RFA is a safe and effective treatment in Korean patients with T1a RCC because of excellent mid-term outcomes.

  9. CT-Guided Radiofrequency Ablation of T1a Renal Cell Carcinoma in Korea: Mid-Term Outcomes

    International Nuclear Information System (INIS)

    Kim, Hae Jin; Park, Byung Kwan; Park, Jung Jae; Kim, Chan Kyo

    2016-01-01

    To evaluate the mid-term outcomes of percutaneous radiofrequency ablation (RFA) treatment in patients with small (< 4 cm) renal cell carcinoma (RCC) in Korea. Between 2010 and 2015, 51 patients (40 men and 11 women; median age, 57 years) with biopsyproven 51 RCC were treated using CT-guided RFA. All patients were clinically staged T1aN0M0 prior to RFA. The median tumor size and follow-up period were 2.1 cm (range, 1.0–3.9 cm) and 26 months (4–60 months), respectively. Local tumor progression, distant metastasis, primary and secondary effectiveness rates, and major complication rates were recorded. Estimated glomerular filtration rates (GFRs) between pre-RFA and last follow-up were compared using paired t tests. The 2-year recurrence-free survival rate was calculated using Kaplan-Meier survival analysis. Of the 51 patients, 2 (3.9%) experienced local tumor progression, and 1 (2.0%) had lymph node metastasis after the first RFA session. Primary and secondary effectiveness rates were 96.1% (49/51) and 100% (1/1), respectively. Only 1 patient experienced a major complication (uretero-pelvic stricture) after the second RFA session for treating a local tumor progression, and the major complication rate was 1.9% (1/52). The median pre-RFA and last follow-up GFRs were 87.1 mL/ min/1.73 m 2 (14.2–142.7 mL/min/1.73 m 2 ) and 72.0 mL/min/1.73 m 2 (7.2–112.6 mL/min/1.73 m 2 ), respectively (p < 0.0001). The 2-year recurrence-free survival rate was 96.0%. CT-guided RFA is a safe and effective treatment in Korean patients with T1a RCC because of excellent mid-term outcomes

  10. Oxide particle size distribution from shearing irradiated and unirradiated LWR fuels in Zircaloy and stainless steel cladding: significance for risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Davis, W. Jr.; West, G.A.; Stacy, R.G.

    1979-03-22

    Sieve fractionation was performed with oxide particles dislodged during shearing of unirradiated or irradiated fuel bundles or single rods of UO/sub 2/ or 96 to 97% ThO/sub 2/--3 to 4% UO/sub 2/. Analyses of these data by nonlinear least-squares techniques demonstrated that the particle size distribution is lognormal. Variables involved in the numerical analyses include lognormal median size, lognormal standard deviation, and shear cut length. Sieve-fractionation data are presented for unirradiated bundles of stainless-steel-clad or Zircaloy-2-clad UO/sub 2/ or ThO/sub 2/--UO/sub 2/ sheared into lengths from 0.5 to 2.0 in. Data are also presented for irradiated single rods (sheared into lengths of 0.25 to 2.0 in.) of Zircaloy-2-clad UO/sub 2/ from BWRs and of Zircaloy-4-clad UO/sub 2/ from PWRs. Median particle sizes of UO/sub 2/ from shearing irradiated stainless-steel-clad fuel ranged from 103 to 182 ..mu..m; particle sizes of ThO/sub 2/--UO/sub 2/, under these same conditions, ranged from 137 to 202 ..mu..m. Similarly, median particle sizes of UO/sub 2/ from shearing unirradiated Zircaloy-2-clad fuel ranged from 230 to 957 ..mu..m. Irradiation levels of fuels from reactors ranged from 9,000 to 28,000 MWd/MTU. In general, particle sizes from shearing these irradiated fuels are larger than those from the unirradiated fuels; however, unirradiated fuel from vendors was not available for performing comparative shearing experiments. In addition, variations in particle size parameters pertaining to samples of a single vendor varied as much as those between different vendors. The fraction of fuel dislodged from the cladding is nearly proportional to the reciprocal of the shear cut length, until the cut length attains some minimum value below which all fuel is dislodged. Particles of fuel are generally elongated with a long-to-short axis ratio usually less than 3. Using parameters of the lognormal distribution estimates can be made of fractions of dislodged fuel having

  11. Pulmonary Metastasis from Rectal Cancer on Chest CT Is Correlated with 3T MRI Primary Tumor Location

    International Nuclear Information System (INIS)

    Han, Na Yeon; Kim, Min Ju; Park, Beon Jin; Sung, Deuk Jae; Chung, Kyoo Byung; Oh, Yu Whan

    2011-01-01

    To evaluate the association between the incidence of pulmonary metastasis on chest CT and the location of the primary tumor on rectal MRI. One hundred and nine consecutive patients with rectal adenocarcinoma underwent chest CT and 3T rectal MRI. Two radiologists classified the tumor on MRI as an upper (> 10 cm from the anal verge), mid (5-10 cm), or lower rectal tumor (< 5 cm) by consensus. All chest CT scans were retrospectively reviewed for the presence of metastasis. We used Fisher's exact test to evaluate the correlation between the incidence of pulmonary metastasis with the location of the rectal cancer and the Mantel-Haenszel test to control for local tumor stage. We only included the 60 patients with upper (n = 26) or lower (n = 34) rectal cancer, because of the complicated venous drainage system of the mid rectum. Among these, 9 (15%) showed evidence of pulmonary metastasis on chest CT and almost all (89%, 8/9) patients had lower rectal cancer. The incidence of pulmonary metastasis between the two groups was statistically different (p < 0.05) when local tumor stage was controlled. The incidence of pulmonary metastasis was significantly higher for lower than upper rectal cancers when the T-stage of the tumor was accounted for.

  12. CT perfusion study of neck lymph nodes

    International Nuclear Information System (INIS)

    Zhong Jin; Liu Jun; Hua Rui; Qiao Hui; Gong Yi

    2011-01-01

    Objective: To study the CT perfusion features of various lymph nodes in the neck. Methods: Dynamic perfusion CT scanning was performed in 83 neck lymph nodes proved by pathology, including tuberculosis lymph nodes, lymphoma and metastatic lymph nodes. The shapes, blood flow modes, and perfusion parameters of these lymph nodes were compared among 3 groups. Statistical analysis of L/T and CT perfusion parameters was performed by one-way ANOVA and LSD test. Results: The values of MTT of tuberculosis lymph nodes, lymphoma and metastatic lymph nodes were (28.13±5.08), (31.08±5.82), and (11.24±5.31) s, respectively. The MTT of metastatic lymph nodes was statistically lower than that of tuberculosis lymph nodes and lymphoma (P -1 · 100 g -1 , respectively. The values of BV were (24.68±2.84), (25.30±3.16), and (25.15± 8.81) ml·100 g -1 respectively. The values of TTP were (40.90±8.85), (40.67±6.45), and (40.98±6.62) s, respectively. There were no significant differences in L/T, BF, BV and TTP among tuberculosis lymph nodes, lymphoma and metastatic lymph nodes (P>0.05). Conclusion: CT perfusion, especially combination functional imaging with perfusion images may be helpful in judging the nature of neck lymph nodes. (authors)

  13. Comparison of CT and MRI artefacts from coils and vascular plugs used for portal vein embolization

    Energy Technology Data Exchange (ETDEWEB)

    Geisel, Dominik, E-mail: dominik.geisel@charite.de [Department of Diagnostic and Interventional Radiology, Charité, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Gebauer, Bernhard [Department of Diagnostic and Interventional Radiology, Charité, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Malinowski, Maciej; Stockmann, Martin [Department of General, Visceral and Transplantation Surgery, Charité, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Denecke, Timm [Department of Diagnostic and Interventional Radiology, Charité, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany)

    2014-04-15

    Purpose: To retrospectively analyze the degree of artefacts in CT and MRI scans caused by coils and vascular plugs used for portal vein embolization (PVE). Materials and methods: All patients who underwent PVE between July 2011 and December 2012 and received either plug or coil embolization additional to particle embolization were retrospectively analyzed. Artefacts causes by embolization materials were measured in CT and MRI scans following PVE. Results: The sum of the artefact diameters caused from coils was significantly higher in CT (188.3 ± 26.1 mm) than in MRI T1 (50.5 ± 6.5 mm) or T2 imaging (39.5 ± 9.7 mm) (P < 0.05). In MRI, the diameter in T1 and T2 sequences did not differ significantly (P = 0.977). The sum of the artefact diameters from vascular plugs in MRI T1 sequences (62.5 ± 8.7 mm) was significantly higher than in CT (46.6 ± 4.8 mm; P < 0.05) and MRI T2 sequences (52.8 ± 3.8 mm; P < 0.05). Conclusion: PVE with particles and vascular plug causes significantly fewer artefacts than PVE with particles and coils on CT scans following embolization, which can be important in the event of vascular complications or in follow-up scans, should the patient become unresectable.

  14. CT and MR findings of primitive neuroectodermal tumor

    International Nuclear Information System (INIS)

    Kook, Shin Ho; Kim, In One; Chang, Kee Hyun; Han, Moon Hee; Cho, Byung Kyu

    1991-01-01

    Cerebral primitive neuroectodermal tumor (PNET), consisting of undifferentiated primitive cells, is a neoplasm of children and young adults that occurs predominantly in the supratentorial compartment. In this report, we retrospectively reviewed and analyzed 18 CT and 6 MR findings in 18 patients with pathologically-proven PNET to discover the characteristic findings, if may. The most characteristic feature of the PNETs was a well-defined multilobular oval or round large mass with components of peripheral cystic change or calcification in the cerebral hemisphere, especially in the parietal lobe. Usually there was only minimal surrounding edema. The CT density of the tumor was iso - or slightly high density with homogeneous contrast enhancement in the solid portion and low density in the cystic area. MR findings demonstrated iso - signal intensity on both T1 - weighted (T1WI) and T2-weighted (T2WI) images and dense enhancement in the solid element. The cystic portion revealed low intensity on T1WI and high intensity on T2WI

  15. Intranasal delivery of cholera toxin induces th17-dominated T-cell response to bystander antigens.

    Directory of Open Access Journals (Sweden)

    Jee-Boong Lee

    Full Text Available Cholera toxin (CT is a potent vaccine adjuvant, which promotes mucosal immunity to protein antigen given by nasal route. It has been suggested that CT promotes T helper type 2 (Th2 response and suppresses Th1 response. We here report the induction of Th17-dominated responses in mice by intranasal delivery of CT. This dramatic Th17-driving effect of CT, which was dependent on the B subunit, was observed even in Th1 or Th2-favored conditions of respiratory virus infection. These dominating Th17 responses resulted in the significant neutrophil accumulation in the lungs of mice given CT. Both in vitro and in vivo treatment of CT induced strongly augmented IL-6 production, and Th17-driving ability of CT was completely abolished in IL-6 knockout mice, indicating a role of this cytokine in the Th17-dominated T-cell responses by CT. These data demonstrate a novel Th17-driving activity of CT, and help understand the mechanisms of CT adjuvanticity to demarcate T helper responses.

  16. Tensile and fracture toughness properties of copper alloys and their HIP joints with austenitic stainless steel in unirradiated and neutron irradiated condition

    International Nuclear Information System (INIS)

    Taehtinen, S.; Pyykkoenen, M.; Singh, B.N.; Toft, P.

    1998-03-01

    The tensile strength and ductility of unirradiated CuAl25 IG0 and CuCrZr alloys decreased continuously with increasing temperature up to 350 deg C. Fracture toughness of unirradiated CuAl25 IG0 alloy decreased continuously with increasing temperature from 20 deg C to 350 deg C whereas the fracture toughness of unirradiated CuCrZr alloy remained almost constant at temperatures up to 100 deg C, was decreased significantly at 200 deg C and slightly increased at 350 deg C. Fracture toughness of HIP joints were lower than that of corresponding copper alloy and fracture path in HIP joint specimen was always within copper alloy side of the joint. Neutron irradiation to a dose level of 0.3 dpa resulted in hardening and reduction in uniform elongation to about 2-4% at 200 deg C in both copper alloys. At higher temperatures softening was observed and uniform elongation increased to about 5% and 16% for CuAl25 IG0 and CuCrZr alloys, respectively. Fracture toughness of CuAl25 IG0 alloy reduced markedly due to neutron irradiation in the temperature range from 20 deg C to 350 deg C. The fracture toughness of the irradiated CuCrZr alloy also decreased in the range from 20 deg C to 350 deg C, although it remained almost unaffected at temperatures below 200 deg C and decreased significantly at 350 deg C when compared with that of unirradiated CuCrZr alloy. (orig.)

  17. The effect of compressive stress on the Young's modulus of unirradiated and irradiated nuclear graphites

    International Nuclear Information System (INIS)

    Oku, T.; Usui, T.; Ero, M.; Fukuda, Y.

    1977-01-01

    The Young's moduli of unirradiated and high temperature (800 to 1000 0 C) irradiated graphites for HTGR were measured by the ultrasonic method in the direction of applied compressive stress during and after stressing. The Young's moduli of all the tested graphites decreased with increasing compressive stress both during and after stressing. In order to investigate the reason for the decrease in Young's modulus by applying compressive stress, the mercury pore diameter distributions of a part of the unirradiated and irradiated specimens were measured. The change in pore distribution is believed to be associated with structural changes produced by irradiation and compressive stressing. The residual strain, after removing the compressive stress, showed a good correlation with the decrease in Young's modulus caused by the compressive stress. The decrease in Young's modulus by applying compressive stress was considered to be due to the increase in the mobile dislocation density and the growth or formation of cracks. The results suggest, however, that the mechanism giving the larger contribution depends on the brand of graphite, and in anisotropic graphite it depends on the direction of applied stress and the irradiation conditions. (author)

  18. CT staging of renal pelvis tumor

    International Nuclear Information System (INIS)

    Yoon, Soo Woong; Cho, Kyoung Sik; Lee, Jong Hwa; Ham, Su Yeon; Won, Yeong Cheol; Ji, Eun Kyung; Choi, Seong Hun; Shin, Byung Suck

    1999-01-01

    To assess the value of computed tomography (CT) in the preoperative staging of transitional cell carcinoma (TCC) of the renal pelvis. We retrospectively evaluated the CT TNM staging of 38 patients with TCC of the renal pelvis who had undergone preoperative abdominal CT examination between January 1990 and January 1998. In CT staging for differentiation between early-stage (T0-2) and advanced-stage disease (T3-T4), three criteria were used, namely the presence or obliteration of the renal sinus fat layer, the smoothness or irregularity of margin between the tumor and renal parenchyma, and the presence or absence of hydronephrosis proximal to the tumor. CT staging was performed by two genitourinary radiologists blinded to the pathologic results, and was compared with pathologic staging. Pathologic results revealed 19 cases of early stage disease (T0=8, T1=9, T2=2) and 19 of advanced stage (T3=12, T4=7). Overall CT staging accuracy was 82%(31/38) ; four cases were overstaged and three were understaged. In early-stage disease, sensitivity and specificity were 79%, and 84%, and in advanced stage disease were 83% and 80%. Three of four overstaged cases showed hydronephrosis proximal to the tumor. In the second CT staging, using proximal hydronephrosis of the tumor as a criterion for early-stage disease, the sensitivity and specificity of early-stage disease were 95% and 75%, respectively, and the specificity of advanced-stage disease was 95%. When hydronephrosis proximal to a tumor was considered to be a sign of early stage disease, the CT staging of renal pelvic TCC was highly accurate

  19. Diagnosis value of dual-phase contrast enhancement CT combined with virtual non-enhanced images by dual-energy CT in clear cell renal cell carcinoma

    International Nuclear Information System (INIS)

    Ma Zhoupeng; Zhou Jianjun; Liu Xueling; Wang Chun; Zhang Shunzhuang

    2012-01-01

    Objective: To explore the diagnostic value of dual-phase contrast enhancement CT combined with virtual non-enhanced images by dual-energy CT in clear cell renal cell carcinoma. Methods: Sixty patients who were suspected of clear cell renal cell carcinoma underwent non-enhanced CT and contrast enhancement CT of early interface-phase between cortex -medulla and parenchymal phase on a dual-energy CT. The true non-enhanced kidney CT (TNCT) was performed in a single-energy acquisition mode, but the dual-phase contrast enhancement CT were performed in a dual-energy mode of 80 kV and 140 kV respectively. The virtual non-enhanced CT (VNCT) images were derived from the data of early interface phase using liver virtual non-contrast software. The diagnose according to VNCT combined dual-phase contrast enhancement CT and dual-phase contrast enhancement CT only were made respectively and compared with χ 2 test. Between the true non-contrast CT and the virtual non-contrast CT, the image quality was compared with Wilcoxon test; The radiation dose of volume CT dose index (CTDIvol) and dose length product(DLP) in a single-phase and total examination, the mean CT HU values of the tumours were compared with t test. Results: The accuracy of VNCT combined dual-phase contrast enhancement CT was higher than that of dual-phase contrast enhancement CT only [93.3% (56/60) vs.78.3% (47/60); χ 2 =5.6, P<0.05]. The detective ability (score) of VNCT was near to that of TNCT and the difference was not obvious (Z=0.00, P>0.05). The radiation dose of volume CT dose index (CTDIvol) and dose length product (DLP) in a single phase and total examination of VNCT [(8.85 ± 1.28) mGy, (196.45 ±21.12) mGy·cm, (17.69±2.35) mGy, (392.90±42.25) mGy · cm] were lower than that of TNCT [(10.20 ± 1.44) mGy,(218.29 ± 29.60) mGy · cm, (30.61 ± 3.27) mGy and (654.86 ± 88.81) mGy ·cm], t=4.21, 3.58, 23.63, 16.12 respectively, P<0.05. The mean CT HU values of tumours on VNCT images was higher than that

  20. Lesion detection performance: comparative analysis of low-dose CT data of the chest on two hybrid imaging systems.

    Science.gov (United States)

    Jessop, Maryam; Thompson, John D; Coward, Joanne; Sanderud, Audun; Jorge, José; de Groot, Martijn; Lança, Luís; Hogg, Peter

    2015-03-01

    Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). JAFROC analysis showed a significant difference (P detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified. © 2015 by the Society of Nuclear Medicine and Molecular Imaging

  1. CT and MR imaging findings of sinonasal angiomatous polyps

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Jing [Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong (China); Man, Fengyuan [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing (China); Deng, Kai [Department of Radiology, Qingdao No. 4 People' s Hospital, Qingdao, Shandong (China); Zheng, Yuanyuan [Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong (China); Hao, Dapeng, E-mail: haodp_2009@163.com [Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong (China); Xu, Wenjian, E-mail: cjr.xuwenjian@vip.163.com [Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong (China)

    2014-03-15

    Objective: To characterize the CT and MR imaging findings of patients with sinonasal angiomatous polyps (SAPs) and evaluate their respective clinical value in the diagnosis of SAP. Methods: CT and MR imaging findings of 15 patients with pathologically proven SAP were examined. Assessed image features included location, size, margin, attenuation, and change of the bony walls of the sinonasal cavity on CT, and signal intensity and enhancement pattern on MR. Results: On CT, the SAP was mostly isoattenuated with patches of slight hyperattenuation. Most lesions caused changes in the adjacent bone, including expansile remodeling (n = 8), defect or destruction (n = 7), and hyperostosis (n = 6). All lesions examined by MR showed heterogeneous isointense signal intensity on T1-weighted images and mixed obvious hyperintense and hypointense signal intensity with linear hypointense septum internally (n = 10), and hypointense peripheral rim on T2-weighted images (n = 10). Postcontrast MR images demonstrated areas of heterogeneous and marked enhancement with an unenhanced hypointense rim and septa (n = 7). Conclusions: CT and MR imaging have respective advantages in the diagnosis of SAP. Combined application of CT and MR examinations is necessary for patients with suspected SAP.

  2. CT and MR imaging findings of sinonasal angiomatous polyps

    International Nuclear Information System (INIS)

    Zou, Jing; Man, Fengyuan; Deng, Kai; Zheng, Yuanyuan; Hao, Dapeng; Xu, Wenjian

    2014-01-01

    Objective: To characterize the CT and MR imaging findings of patients with sinonasal angiomatous polyps (SAPs) and evaluate their respective clinical value in the diagnosis of SAP. Methods: CT and MR imaging findings of 15 patients with pathologically proven SAP were examined. Assessed image features included location, size, margin, attenuation, and change of the bony walls of the sinonasal cavity on CT, and signal intensity and enhancement pattern on MR. Results: On CT, the SAP was mostly isoattenuated with patches of slight hyperattenuation. Most lesions caused changes in the adjacent bone, including expansile remodeling (n = 8), defect or destruction (n = 7), and hyperostosis (n = 6). All lesions examined by MR showed heterogeneous isointense signal intensity on T1-weighted images and mixed obvious hyperintense and hypointense signal intensity with linear hypointense septum internally (n = 10), and hypointense peripheral rim on T2-weighted images (n = 10). Postcontrast MR images demonstrated areas of heterogeneous and marked enhancement with an unenhanced hypointense rim and septa (n = 7). Conclusions: CT and MR imaging have respective advantages in the diagnosis of SAP. Combined application of CT and MR examinations is necessary for patients with suspected SAP

  3. CT and MR findings of ovarian fibroma

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Soo Jin; Rho, Myung Ho; Kim, Byung Heon; Song, Yun Gyu; Lee, Soo Han; Choi, Pil Yeob; Sung, Young Soon; Kwon, Jae Soo; Lee, Sang Wook [Masan Samsung Hospital, Masan (Korea, Republic of)

    1997-08-01

    To evaluate the charateristic CT and MR findings of the primary ovarian fibromas. We retrospectively reviewed 11 cases which had undergone precontrast and postcontrast scanning, and two in which cases T1-weighted (WI) and postcontrast T1WI and T2WI images had been done. All cases were pathologically confirmed after surgical resection. These masses were analysed on the bases of clinical symptoms, age, size(longest diameter), laterality, margin, attenuation(unenhanced and enhanced), signal intensity(SI), calcification, and amount of the ascites. The patients' mean age was 46.6(range, 22-81)years, and the longest diameter was 14.8(range, 8-28)cm. All tumors were unilateral, and eight were located in the left ovary and five in the right ovary. In all cases, the tumor margin was well-defined;seven were lobulated, four were oval, one was round, and one was nodularly marginated. On CT scan, the masses showed mild to moderate heterogenous enhancement with irregular lower density portions. The amount of the ascites was marked in three cases(23%), mild in two(15%), and minimal in three cases. Calcification were seen in 3 of 11 CT cases(27%), and in one, this was extensive. On MR scans, signal intensity (SI) of the masses on T1WI was isoSI, relativetive to the uterine myometrium, and heterogeneously enhanced after infusion of contrast media. On T2WI, SI was slightly lower that of the uterine myometrium with internal high SI portions. The characteristic finding of ovarian fibroma is a unilateral, well-defined, oval or lobulated, solid mass with or without ascites and calcification. On CT scan, tumor has mild to moderate heterogeneous enhancement. On MR scan, SI of mass is isoSI on T1WI with heterogeneous enhancement, and low SI on T2WI due to fibrous component.

  4. Phenotype of Usher syndrome type II assosiated with compound missense mutations of c.721 C>T and c.1969 C>T in MYO7A in a Chinese Usher syndrome family.

    Science.gov (United States)

    Zhai, Wei; Jin, Xin; Gong, Yan; Qu, Ling-Hui; Zhao, Chen; Li, Zhao-Hui

    2015-01-01

    To identify the pathogenic mutations in a Chinese pedigree affected with Usher syndrome type II (USH2). The ophthalmic examinations and audiometric tests were performed to ascertain the phenotype of the family. To detect the genetic defect, exons of 103 known RDs -associated genes including 12 Usher syndrome (USH) genes of the proband were captured and sequencing analysis was performed to exclude known genetic defects and find potential pathogenic mutations. Subsequently, candidate mutations were validated in his pedigree and 100 normal controls using polymerase chain reaction (PCR) and Sanger sequencing. The patient in the family occurred hearing loss (HL) and retinitis pigmentosa (RP) without vestibular dysfunction, which were consistent with standards of classification for USH2. He carried the compound heterozygous mutations, c.721 C>T and c.1969 C>T, in the MYO7A gene and the unaffected members carried only one of the two mutations. The mutations were not present in the 100 normal controls. We suggested that the compound heterozygous mutations of the MYO7A could lead to USH2, which had revealed distinguished clinical phenotypes associated with MYO7A and expanded the spectrum of clinical phenotypes of the MYO7A mutations.

  5. Some mechanisms of disturbances and recovery of T-lymphocyte migratory properties in irradiated mice

    International Nuclear Information System (INIS)

    Anokhin, G.N.; Yarilin, A.A.

    1984-01-01

    Migration of 51 Cr-labelled T cells from irradiated mice into lymph nodes of syngeneic unirradiated recipients decreased in a dose-dependent fashion. Influx of labelled T cells between 4 and 24 hr after injection (secondary migration) is more radiosensitive than lymph-node migration of T cells in the first 4 hr (primary migration). Treatment of T cells from irradiated mice in vitro with Con A or with trypsin does not enhance radiation-induced alteration of their migratory properties, but irradiation enhances the effects of Con A and trypsin on T-cell migration. Recovery of primary migration of irradiated T cells is completed 3 months after irradiation; it is probably caused by T-cell renewal. The defect of T-cell secondary migration is more stable: it remains 6 months after irradiation in a dose of 4 gy. Post-irradiation defects of the T-cell differentiation process as a cause of long-lasting alteration of T-cell secondary migration are discussed. (author)

  6. Sperm quantity and size variation in un-irradiated and irradiated males of the malaria mosquito Anopheles arabiensis Patton

    NARCIS (Netherlands)

    Helinski, M.; Knols, B.G.J.

    2009-01-01

    Anopheles mosquitoes are important candidates for genetic control strategies. However, little is known about sperm quality and quantity as determinants of male reproductive success. In this study, sperm quantity and length variation were assessed in testes of un-irradiated and irradiated Anopheles

  7. Erythrokinetics in mice bearing tumours in either preirradiated or unirradiated tissue

    International Nuclear Information System (INIS)

    Jirtle, R.L.; Clifton, K.H.

    1978-01-01

    Experiments were designed to clarify the causes of anaemia in hosts bearing tumours in either unirradiated or preirradiated tissue. Isotopic methods are described which enable the estimation of erythrocyte destruction and production rates, and the potential red cell life spans in tumour-bearing animals. In this experimental system, anaemia (a) is in large part due to accelerated random erythrocyte loss, (b) is exacerbated as tumours grow by a progressive reduction in the potential erythrocyte life span due to intrinsic erythrocyte defects. (c) is accompanied by an increase in erythrocyte production of six- to ten-fold and (d) is postponed in onset and decreased in magnitude by preirradiation of the tumour transplant site. (author)

  8. Erythrokinetics in mice bearing tumours in either preirradiated or unirradiated tissue

    Energy Technology Data Exchange (ETDEWEB)

    Jirtle, R L; Clifton, K H [Wisconsin Univ., Madison (USA). Div. of Clinical Oncology

    1978-11-01

    Experiments were designed to clarify the causes of anaemia in hosts bearing tumours in either unirradiated or preirradiated tissue. Isotopic methods are described which enable the estimation of erythrocyte destruction and production rates, and the potential red cell life spans in tumour-bearing animals. In this experimental system, anaemia (a) is in large part due to accelerated random erythrocyte loss, (b) is exacerbated as tumours grow by a progressive reduction in the potential erythrocyte life span due to intrinsic erythrocyte defects. (c) is accompanied by an increase in erythrocyte production of six- to ten-fold and (d) is postponed in onset and decreased in magnitude by preirradiation of the tumour transplant site.

  9. CT and MRI Findings of Soft Tissue Adult Fibrosarcoma in Extremities

    Directory of Open Access Journals (Sweden)

    Hexiang Wang

    2018-01-01

    Full Text Available Objective. To characterize and evaluate CT and MRI features of extremity soft tissue adult fibrosarcoma. Methods. CT and MRI images from 10 adult patients with pathologically proven fibrosarcomas were retrospectively analyzed with regard to tumor location, size, number, shape, margins, attenuation, signal intensity, and enhancement patterns on MR images. Additionally, the relationships between lesions, deep fascia, and change in adjacent bones were also assessed. Results. Nineteen tumor lesions in 10 patients were selected for this study. Eighteen lesions were lobulated and one was oval in shape. Most cases were located under the deep fascia, including seven cases that had a nodular lump adjacent to the deep fascia and one case that had broken lesion through the deep fascia. On CT, the adult fibrosarcomas mostly showed iso-attenuated soft tissue masses (n=6. On MRI, all the cases (n=9 displayed low signal on T1-weighted imaging (T1WI and heterogeneous low and high intensity signals on T2-weighted imaging (T2WI, with band-like areas of low signal on both T1WI and T2WI. On contrast-enhanced MRI images, three cases showed heterogeneous peripheral enhancement and one case demonstrated a spoke-wheel-like enhancement. Eight cases showed muscle edema signals in the peritumoral muscle and one case involved adjacent bone. Conclusion. CT and MR imaging have respective advantages in diagnosing adult fibrosarcoma. Combined application of CT and MR is recommended for patients with suspected adult fibrosarcoma.

  10. Comparison of fracture toughness values from large-scale pipe system tests and C(T) specimens

    International Nuclear Information System (INIS)

    Olson, R.; Scott, P.; Marschall, C.; Wilkowski, G.

    1993-01-01

    Within the International Piping Integrity Research Group (IPIRG) program, pipe system experiments involving dynamic loading with intentionally circumferentially cracked pipe were conducted. The pipe system was fabricated from 406-mm (16-inch) diameter Schedule 100 pipe and the experiments were conducted at 15.5 MPa (2,250 psi) and 288 C (550 F). The loads consisted of pressure, dead-weight, thermal expansion, inertia, and dynamic anchor motion. Significant instrumentation was used to allow the material fracture resistance to be calculated from these large-scale experiments. A comparison of the toughness values from the stainless steel base metal pipe experiment of standard quasi-static and dynamic C(T) specimen tests showed the pipe toughness value was significantly lower than that obtained from C(T) specimens. It is hypothesized that the cyclic loading from inertial stresses in this pipe system experiment caused local degradation of the material toughness. Such effects are not considered in current LBB or pipe flaw evaluation criteria. 4 refs., 14 figs., 1 tab

  11. C.T. scan based dosimetry in treating carcinoma of oral tongue

    International Nuclear Information System (INIS)

    Sudarshan, G.; Ranganathan, Vanisehree

    1999-01-01

    It is a well established norm that a combination of external radiation and iridium implant in early stage squamous cell carcinoma (SCC) of oral tongue gives good results. We have treated 10 consecutive patients of SCC of anterior 2/3 of tongue staged T1-2 NO by giving 4000 cGy external radiation and 3000 cGy boost with iridium-192 implant. Traditionally, orthogonal radiographs have been taken to determine the spatial distribution of sources. As we do not have a simulator, we have taken 2-4 C.T. scan images perpendicular to the axis of implant. By using this cross-sectional information, we identified the source points and a basal dose rate was calculated manually by following the geometric principles of Paris system as our T.P.S. did not have the required software. Clinically, 9 out of the 10 patients are in remission (N.E.D. = No evidence of disease) at 18 months follow-up. Our aim of this presentation is to compare manual dosimetry with T.P.S. generated dosimetry and to show that manual dosimetry is also dependable. (author)

  12. Hyperhomocysteinemia, methylenetetrahydrofolate reductase c.677C>T polymorphism and risk of cancer: cross-sectional and prospective studies and meta-analyses of 75,000 cases and 93,000 controls

    DEFF Research Database (Denmark)

    Zacho, Jeppe; Yazdanyar, Shiva; Bojesen, Stig E

    2011-01-01

    including 74,671 cases and 93,344 controls. Cross-sectionally, plasma homocysteine levels were 12.9 and 11.6 µmol/L in those with and without cancer (p homocysteine levels increased with age and age-adjusted odds ratio for any cancer in those with homocysteine levels >12.4 versus ....4 µmol/L did not differ from 1.0. In cancer-free participants, plasma homocysteine levels were 14.7 and 11.7 µmol/L in MTHFR c.677C>T homozygtes and noncarriers (p T homozygotes versus noncarriers did not differ...... from 1.0. However, in meta-analyses odds ratio for MTHFR c.677C>T homozygotes versus noncarriers were 1.07 (95% CI: 1.01-1.12) for any cancer, 1.77 (1.17-2.68) for esophagus cancer, 1.40 (1.19-1.66) for gastric cancer and 0.85 (0.77-0.94) for colorectal cancer. Increased plasma homocysteine levels...

  13. In vitro induction of O6-methylguanine-DNA methyltransferase in C3H/10T1/2 cells by X-rays is inhibited by nitrogen

    International Nuclear Information System (INIS)

    Hofe, E. von; Kennedy, A.R.

    1988-01-01

    Ionizing radiation is one of the most potent inducers of O 6 -methylguanine-DNA methyltransferase (MT) in rat liver in vivo. In this study we show that MT is readily induced in C3H/10T1/2 cells in culture, which provides a system more amenable to determining the molecular events involved in the induction of this repair enzyme. Maximal induction was observed in logarithmically growing cells 48 h after a dose of 200 rad, similar to the optimal induction time seen in rat liver in vivo. The absolute level of MT observed in C3H/10T1/2 cells which had been at confluence for 24 h was less than in cells in log growth but was still inducible by X-rays, exhibiting an ∼ 2-fold increase over unirradiated cells similar to MT induction in logarithmically growing cells. Irradiating cells under anaerobic conditions abolished MT induction by 100 rad. Cells irradiated with 200 rad under anaerobic conditions exhibited ∼ 70% inhibition of induction compared with aerobically irradiated cells. The possibility that MT may be partially inactivated by interaction with radicals produced by ionizing radiation is discussed. (author)

  14. CT and MRI findings in cerebral hydatid disease

    International Nuclear Information System (INIS)

    Topal, U.; Parlak, M.; Kilic, E.; Sivri, Z.; Sadikoglu, M.Y.; Tuncel, E.

    1995-01-01

    CT is the primary modality for the diagnosis. Two forms of cerebral hydatid cysts have been reported on the basis of CT appearances: unilocular and multilocular. Demonstration of the cyst wall is important for the diagnosis. MRI is superior to CT for demonstrating the cyst capsule and perifocal oedema. We retrospectively reveiwed the CT and MRI findings of 6 surgically proven cases of cerebral hydatid cyst and compared the two modalities on the basis of their demonstration of findings helpful in the diagnosis, such as the capsule and perifocal oedema. In 1 case CT showed the capsule. In 2 cases MRI showed a hypointense capsule around the cyst on T2-weighted images. While CT is the modality of choice, in clinical practice MRI is superior for demonstrating the cyst capsule, which is a helpful finding in the diagnosis and can be used in inconclusive cases. (orig.)

  15. Correlation between lactose absorption and the C/T-13910 and G/A-22018 mutations of the lactase-phlorizin hydrolase (LCT gene in adult-type hypolactasia

    Directory of Open Access Journals (Sweden)

    A.C. Bulhões

    2007-11-01

    Full Text Available The C/T-13910 mutation is the major factor responsible for the persistence of the lactase-phlorizin hydrolase (LCT gene expression. Mutation G/A-22018 appears to be only in co-segregation with C/T-13910. The objective of the present study was to assess the presence of these two mutations in Brazilian individuals with and without lactose malabsorption diagnosed by the hydrogen breath test (HBT. Ten milk-tolerant and 10 milk-intolerant individuals underwent the HBT after oral ingestion of 50 g lactose (equivalent to 1 L of milk. Analyses for C/T-13910 and G/A-22018 mutations were performed using a PCR-based method. Primers were designed for this study based on the GenBank sequence. The CT/GA, CT/AA, and TT/AA genotypes (lactase persistence were found in 10 individuals with negative HBT. The CC/GG genotype (lactase non-persistence was found in 10 individuals, 9 of them with positive HBT results. There was a significant agreement between the presence of mutations in the LCT gene promoter and HBT results (kappa = -0.9, P < 0.001. The CT/AA genotype has not been described previously and seems to be related to lactase persistence. The present study showed a significant agreement between the occurrence of mutations G/A-22018 and C/T-13910 and lactose absorption in Brazilian subjects, suggesting that the molecular test used here could be proposed for the laboratory diagnosis of adult-type primary hypolactasia.

  16. SU-E-T-70: Commissioning a Multislice CT Scanner for X-Ray CT Polymer Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, H [University of Victoria, Victoria, BC (Australia); UT Southwestern Medical Center, Dallas, TX (United States); Hilts, M [University of Victoria, Victoria, BC (Australia); BC Cancer Agency, Kelowna, BC (Australia); Jirasek, A [University of Victoria, Victoria, BC (Australia)

    2014-06-01

    Purpose: To commission a multislice computed tomography (CT) scanner for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD). Methods: Commissioning was performed for a 16-slice CT scanner using images acquired through a 1L cylinder filled with water. Additional images were collected using a single slice machine for comparison purposes. The variability in CT number associated with the anode heel effect was evaluated and used to define a new slice-by-slice background image subtraction technique. Image quality was assessed for the multislice system by comparing image noise and uniformity to that of the single slice machine. The consistency in CT number across slices acquired simultaneously using the multislice detector array was also evaluated. Finally, the variability in CT number due to increasing x-ray tube load was measured for the multislice scanner and compared to the tube load effects observed on the single slice machine. Results: Slice-by-slice background subtraction effectively removes the variability in CT number across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image quality for the multislice machine was found to be comparable to that of the single slice scanner. Further study showed CT number was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thickness examined. In addition, the multislice system was found to eliminate variations in CT number due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to imaging a large volume using a single slice scanner. Conclusion: A multislice CT scanner has been commissioning for CT PGD, allowing images of an entire dose distribution to be acquired in a matter of minutes. Funding support provided by the Natural Sciences and Engineering

  17. Influence of interleukin-1β and interleukin-6 gene polymorphisms on the development of acute pancreatitis.

    Science.gov (United States)

    Chi, D Z; Chen, J; Huang, D P

    2015-02-03

    We investigated the association between 3 main proinflammatory cytokines [interleukin (IL)-1β and IL-6] and the risk of acute pancreatitis. Polymerase chain reaction-restriction fragment length polymorphism was used to genotype IL-1β+3954 C/T (rs1143634) and IL-1β-511 C/T (rs16944) and IL-6 -174 G/C (rs1800795) and IL-6 -634 C/G (rs1800796). The genotype distributions of IL-1β+3954 C/T (rs1143634) and IL-1β-511 C/T (rs16944) and IL-6 -174 G/C (rs1800795) and IL-6 -634 C/G (rs1800796) were in Hardy-Weinberg equilibrium for the control group. Multivariate regression analyses showed that subjects carrying the rs1143634 TT genotype had a significantly increased risk of acute pancreatitis, with an adjusted odds ratio (95% confidence interval) of 2.11 (1.03-4.51). Subjects carrying the IL-1β rs1143634 TT genotype had a significantly increased risk of acute pancreatitis in our Chinese population.

  18. NMR-CT in muscular disorders. Muscle T/sub 1/ values in Duchenne muscular dystrophy carriers

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kiichiro; Nakano, Imaharu; Fukuda, Nobuo; Ikehira, Hiroo; Tateno, Yukio

    1987-02-01

    Proton NMR-CT (magnetic field strength 0.1 Tesla, resonant frequency 4.5 MHz) was performed in 10 normal females and 19 Duchenne muscular dystrophy (DMD) carriers. The mean age was 39 +- 12 years for the normal females and 42 +- 6 years for the DMD carriers. In DMD carriers, there were 4 definite, 4 probable, and 11 possible carriers. T/sub 1/ (spin-lattice relaxation time) image was obtained for a slice at the buttock, mid-thigh and calf levels respectively. T/sub 1/ values were measured for the medial portion of the gluteus maximus, the vastus lateralis of the quadriceps femoris, and the gastrocnemius. The bound water fraction (BWF) was calculated from Fullerton's equation based on the fast proton diffusion model. The following results were obtained: (1) In normal females, muscle T/sub 1/ value was highest in the gastrocnemius and lowest in the gluteus maximus. (2) In DMD carriers, T/sub 1/ values of the gluteus maximus and quadriceps femoris were significantly higher than those of the normal females. There was, however, no significant difference in T/sub 1/ value of the gastrocnemius between DMD carriers and normal females. (3) In DMD carriers, BWFs of the gluteus maximus and quadriceps femoris were significantly lower than those of the normal females. (4) In DMD carriers, no significant correlation was observed between the muscle T/sub 1/ values and the serum creatine phosphokinase values. Increased tissue water content in the lower parts of the body due to gravity is considered to be the primary cause of the high T/sub 1/ value in the gastrocnemius of normal females. The presence of the degenerating muscle fibers are presumed responsible for the high T/sub 1/ value and low BWF in the proximal muscles of DMD carriers.

  19. NMR-CT in muscular disorders. Muscle T/sub 1/ values in Duchenne muscular dystrophy carriers

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kiichiro; Nakano, Imaharu; Fukuda, Nobuo; Ikehira, Hiroo; Tateno, Yukio

    1987-02-01

    Proton NMR-CT (magnetic field strength 0.1 Tesla, resonant frequency 4.5 MHz) was performed in 10 normal females and 19 Duchenne muscular dystrophy (DMD) carriers. The mean age was 39 +- 12 years for the normal females and 42 +- 6 years for the DMD carriers. In DMD carriers, there were 4 definite, 4 probable, and 11 possible carriers. T/sub 1/ (spin-lattice relaxation time) image was obtained for a slice at the buttock, mid-thigh and calf levels respectively. T/sub 1/ values were measured for the medial portion of the gluteus maximus, the vastus lateralis of the quadriceps femoris, and the gastrocnemius. The bound water fraction (BWF) was calculated from Fullerton's equation based on the fast proton diffusion model. The following results were obtained: (1) In normal females, muscle T/sub 1/ value was highest in the gastrocnemius and lowest in the gluteus maximus. (2) In DMD carriers, T/sub 1/ values of the gluteus maximus and quadriceps femoris were significantly higher than those of the normal females. There was, however, no significant difference in T/sub 1/ value of the gastrocnemius between DMD carriers and normal females. (3) In DMD carriers, BWFs of the gluteus maximus and quadriceps femoris were significantly lower than those of the normal females. (4) In DMD carriers, no significant correlation was observed between the muscle T/sub 1/ values and the serum creatine phosphokinase values. Increased tissue water content in the lower parts of the body due to gravity is considered to be the primary cause of the high T/sub 1/ value in the gastrocnemius of normal females. The presence of the degenerating muscle fibers are presumed responsible for the high T/sub 1/ value and low BWF in the proximal muscles of DMD carriers.

  20. F-18 FDG PET/CT Findings of Subcutaneous Panniculitis - Like T- Cell Lymphoma : A Case Report

    International Nuclear Information System (INIS)

    Kong, Eun Jung; Cho, Ihn Ho; Chun, Kyung Ah; Bae, Yeung Kyung; Choi, Joon Hyuk; Hyun, Myung Soo

    2009-01-01

    F-18 FDG PET is a metabolic imaging modality that is efficacious in staging and assessment of treatment response for variety of lymphomas. We report usefulness of F-18 FDG PET/CT in evaluating severity of the disease and response to therapy in a patient with subcutaneous panniculitis- like T-cell lymphoma (SPTCL). Here we describe a case of SPTCL in 24-year-old man who had wide spread firm and tender nodular lesions with increased F-18 FDG uptake. After chemotherapy follow up F-18 FDG PET/CT image shows disseminated malignancy and then the patient died with hemophagocytic syndrome. This report suggests that F-18 FDG PET/CT may be useful in determining disease activity at the time of initial diagnosis, after treatment, and evaluating a suspected outcome of SPTCL

  1. Molecular dynamics study on interfacial thermal conductance of unirradiated and irradiated SiC/C

    International Nuclear Information System (INIS)

    Wang, Qingyu; Wang, Chenglong; Zhang, Yue; Li, Taosheng

    2014-01-01

    SiC f /SiC composite materials have been considered as candidate structural materials for several types of advanced nuclear reactors. Both experimental and computer simulations studies have revealed the degradation of thermal conductivity for this material after irradiation. The objective of this study is to investigate the effect of SiC/graphite interface structure and irradiation on the interfacial thermal conductance by using molecular dynamics simulation. Five SiC/graphite composite models were created with different interface structures, and irradiation was introduced near the interfaces. Thermal conductance was calculated by means of reverse-NEMD method. Results show that there is a positive correlation between the interfacial energy and interfacial C–Si bond quantity, and irradiated models showed higher interfacial energy compared with their unirradiated counterparts. Except the model with graphite atom plane parallel to the interface, the interfacial thermal conductance of unirradiated and irradiated (1000 eV) models, increases as the increase of interfacial energy, respectively. For all irradiated models, lattice defects are of importance in impacting the interfacial thermal conductance depending on the interface structure. For the model with graphite layer parallel to the interface, the interfacial thermal conductance increased after irradiation, for the other models the interfacial thermal conductance decreased. The vibrational density of states of atoms in the interfacial region was calculated to analyze the phonon mismatch at the interface

  2. Esophageal motion characteristics in thoracic esophageal cancer: Impact of clinical stage T4 versus stages T1-T3

    Directory of Open Access Journals (Sweden)

    Yuta Kobayashi, MS

    2016-10-01

    Conclusions: The EM and the ITV margins in cT4 were significantly smaller than those in cT1-T3. The NM and the ITV margins of abdominal LNs were much larger than those of cervicothoracic LNs and the esophagus. In clinical radiation therapy planning for esophageal cancer, we should take cT stage into consideration.

  3. Implications of a RAD54L polymorphism (2290C/T) in human meningiomas as a risk factor and/or a genetic marker

    International Nuclear Information System (INIS)

    Leone, Paola E; Mendiola, Marta; Alonso, Javier; Paz-y-Miño, César; Pestaña, Angel

    2003-01-01

    RAD54L (OMIM 603615, Locus Link 8438) has been proposed as a candidate oncosupressor in tumours bearing a non-random deletion of 1p32, such as breast or colon carcinomas, lymphomas and meningiomas. In a search for RAD54L mutations in 29 menigiomas with allelic deletions in 1p, the only genetic change observed was a silent C/T transition at nucleotide 2290 in exon 18. In this communication the possible association of the 2290C/T polymorphism with the risk of meningiomas was examined. In addition, the usefulness of this polymorphism as a genetic marker within the meningioma consensus deletion region in 1p32 was also verified. The present study comprises 287 blood control samples and 70 meningiomas from Spain and Ecuador. Matched blood samples were only available from Spanish patients. The frequency of the rare allele-T and heterozygotes for the 2290C/T polymorphism in the blood of Spanish meningioma patients and in the Ecuadorian meningioma tumours was higher than in the control population (P < 0.05). Four other rare variants (2290C/G, 2299C/G, 2313G/A, 2344A/G) were found within 50 bp at the 3' end of RAD54L. Frequent loss of heterozygosity for the 2290C/T SNP in meningiomas allowed to further narrow the 1p32 consensus region of deletion in meningiomas to either 2.08 Mbp – within D1S2713 (44.35 Mbp) and RAD54L (46.43 Mbp) – or to 1.47 Mbp – within RAD54L and D1S2134 (47.90 Mbp) – according to recent gene mapping results. The statistical analysis of genotypes at the 2290C/T polymorphism suggest an association between the rare T allele and the development of meningeal tumours. This polymorphism can be used as a genetic marker inside the consensus deletion region at 1p32 in meningiomas

  4. Storage for the Fast Flux Test Facility unirradiated fuel in the Plutonium Finishing Plant Complex, Hanford Site, Richland, Washington

    International Nuclear Information System (INIS)

    1992-01-01

    This Environmental Assessment evaluates the proposed action to relocate and store unirradiated Fast Flux Test Facility fuel in the Plutonium Finishing Plant Complex on the Hanford Site, Richland, Washington. The US Department of Energy has decided to cease fuel fabrication activities in the 308 Building in the 300 Area. This decision was based on a safety concern over the ability of the fuel fabrication portion of the 308 Building to withstand a seismic event. The proposed action to relocate and store the fuel is based on the savings that could be realized by consolidating security costs associated with storage of the fuel. While the 308 Building belowgrade fuel storage areas are not at jeopardy by a seismic event, the US Department of Energy is proposing to cease storage operations along with the related fabrication operations. The US Department of Energy proposes to remove the unirradiated fuel pins and fuel assemblies from the 308 Building and store them in Room 192A, within the 234-5Z Building, a part of the Plutonium Finishing Plant Complex, located in the 200 West Area. Minor modifications to Room 192A would be required to accommodate placement of the fuel. The US Department of Energy estimates that removing all of the fuel from the 308 Building would save $6.5 million annually in security expenditures for the Fast Flux Test Facility. Environmental impacts of construction, relocation, and operation of the proposed action and alternatives were evaluated. This evaluation concluded that the proposed action would have no significant impacts on the human environment

  5. Maternal MTHFR polymorphism (677 C-T) and risk of Down's syndrome child: meta-analysis.

    Science.gov (United States)

    Kaur, Amandeep; Kaur, Anupam

    2016-09-01

    Methylenetetrahydrofolate reductase (MTHFR) is the most important gene that participates in folate metabolism. Presence of valine instead of alanine at position 677 and elevated levels of homocystein causes DNA hypomethylation which in turn favours nondisjunction. In this study, we conducted a meta-analysis to establish link between maternal single-nucleotide polymorphism (SNP) and birth of Down's syndrome (DS) child. A total of 37 case-control studies were selected for analysis including our own, in which we investigated 110 cases and 111 control mothers. Overall, the result of meta-analysis showed significant risk of DS affected by the presence of maternal SNP (MTHFR 677 C-T OR = 0.816, 95% CI = 0.741-0.900, P <0.0001). Heterogeneity of high magnitude was observed among the studies. The chi-square value suggested a highly significant association between homozygous mutant TT genotype and birth of DS child (χ² = 23.63, P = 0.000). Genetic models suggested that 'T' allele possesses high risk for DS whether present in dominant (OR = 1.23, 95% CI = 1.13-1.34); codominant (OR = 1.17, 95% CI = 1.10-1.25) or recessive (OR = 1.21, 95% CI = 1.05-1.38) form. The analysis from all 37 studies combined together suggested that MTHFR 677 C-T is a major risk factor for DS birth.

  6. CT and MRI diagnosis of tubo-ovarian masses

    International Nuclear Information System (INIS)

    Xiong Minghui; Zhang Wanshi; Wang Dong

    2000-01-01

    Objective: To evaluate the diagnostic value of CT and MRI in tubo-ovarian masses. Methods: CT scan was performed in 67 patients with tubo-ovarian masses confirmed by pathology. 19 of them underwent MRI. Results: (1) 20 primary malignant ovarian tumors showed cystic,solid or cystic-solid masses; papillary projections on cystic wall; pelvic organs and pelvic wall invasion. Chocolate cysts with malignant degeneration exhibited small nodules on thickened cystic wall on CT and MRI. T 1 WI was better for revealing the lesions. (2) Of 11 cases of metastasis to tubo-ovary, 4 showed peritoneal linear enhancement. (3) There were 9 cystadenomas and 2 adenofibromas, one of the cystadenomas contained fat, two adenofibromas were similar to uterus in density on CT while showing lower signal intensity on MRI (both T 1 WI and T 2 WI). (4) Three cases of thecoma exhibited cystic or solid masses, solid thecomas revealed granular enhancement. (5) Teratomas were most specific, one of them was associated with thecoma. (6) Tubo-ovarian abscesses and tuberculosis depicted cystic or cystic-solid masses. (7) Two cases of tubal pregnancy showed inhomogeneous soft tissue masses, the lower density areas in the centers were clot and organized tissues confirmed by pathology. Conclusion: (1) CT and MRI had higher sensitivity but lower specificity for tubo-ovarian masses, the diagnosis should be combined with clinical history and patients' age. (2) Tumors of two different types may coexist and sometimes fat may be present in tumors other than teratoma

  7. Synthesis and characterization of 6,6'-bis(2-hydroxyphenyl)-2,2'-bipyridine ligand and its interaction with ct-DNA

    Science.gov (United States)

    Selamat, Norhidayah; Heng, Lee Yook; Hassan, Nurul Izzaty; Karim, Nurul Huda Abd

    2015-09-01

    The tetradentate ligand with four donor atoms OONN was synthesized. Bis(phenoxy)bipyridine ligand was prepared by Suzuki coupling reaction between 6,6'-dibromo-2,2'-bipyridyl and 2-hydroxyphenylboronic acid with presence of palladium (II) acetate. Bis(phenoxy)bipyridine ligand was also synthesized by demethylating of 6,6'-bis(2-methoxyphenyl)-2,2'-bipyridyl ligand through solvent free reaction using pyridine hydrocloride. The formation of both phenoxy and methoxy ligands was confirmed by 1H, 2D cosy and 13C NMR spectroscopy, ESI-MS spectrometry, FTIR spectroscopy. The purity of the ligand was confirmed by melting point. Binding studies of small molecules with DNA are useful to understand the reaction mechanism and to provide guidance for the application and design of new and more efficient drugs targeted to DNA. In this study, the binding interaction between the synthesized ligand with calf thymus-DNA (ct-DNA) has been investigated by UV/Vis DNA titration study. From the UV/Vis DNA study, it shows that bis(phenoxy)bipyridine ligand bind with ct-DNA via outside binding with binding contant Kb = 1.19 × 103 ± 0.08 M-1.

  8. Phenotype of Usher syndrome type II assosiated with compound missense mutations of c.721 C>T and c.1969 C>T in MYO7A in a Chinese Usher syndrome family

    Directory of Open Access Journals (Sweden)

    Wei Zhai

    2015-08-01

    Full Text Available AIM:To identify the pathogenic mutations in a Chinese pedigree affected with Usher syndrome type II (USH2.METHODS:The ophthalmic examinations and audiometric tests were performed to ascertain the phenotype of the family. To detect the genetic defect, exons of 103 known RDs -associated genes including 12 Usher syndrome (USH genes of the proband were captured and sequencing analysis was performed to exclude known genetic defects and find potential pathogenic mutations. Subsequently, candidate mutations were validated in his pedigree and 100 normal controls using polymerase chain reaction (PCR and Sanger sequencing.RESULTS:The patient in the family occurred hearing loss (HL and retinitis pigmentosa (RP without vestibular dysfunction, which were consistent with standards of classification for USH2. He carried the compound heterozygous mutations, c.721 C>T and c.1969 C>T, in the MYO7A gene and the unaffected members carried only one of the two mutations. The mutations were not present in the 100 normal controls.CONCLUSION:We suggested that the compound heterozygous mutations of the MYO7A could lead to USH2, which had revealed distinguished clinical phenotypes associated with MYO7A and expanded the spectrum of clinical phenotypes of the MYO7A mutations.

  9. Three phase dynamic CT with double spiral CT: utility of determination of stomach cancer stage

    International Nuclear Information System (INIS)

    Jung, Min Ha; Kim, Hong In; Kim, Tae Hyung; Lee, Ki Yeol; Cho, June Il; Park, Cheol Min; Cha, In Ho

    1997-01-01

    To evaluate the utility of three phases of spiral CT in the diagnosis of stomach cancer. Between August 1994 and March 1995, thirty eight patients with stomach cancer, demonstrated on spiral CT, underwent surgery. Twenty-eight cases were advanced and ten were early. There were 27 men, and 11 women, and their average age was 52.8 years old (33-77). After ingestion of 600-700ml of water, 120-140ml of nonionic contrast material was injected intravenously. Spiral CT scanning was performed in 10mm slice thickness and of 10mm/sec table speed. Three phase image were obtained at 25sec (arterial phase), 60-65sec (venous phase) and 4min (equilibrium phase) after the start of bolus injection. On each phase, CT findings were compared with pathologic results, and tumor detectibility, depth of tumor invasion and lymph node metastasis was analysed. Thirty of the 38 carcinomas (79%) were detected on the arterial phase, 33 (81%) on the venous phase and 30 (79%) on the equilibrium phase. Depth of tumor invasion was measured accurately in 27 of 38 cases (71%) : T1-4/10 (40%), T2-8/11 (73%), T3-13/15 (87%), T4-2/2 (100%). We overstaged one case of T1 as T2 and two cases of T2 as T3, and understaged one case of T2 as T1 and two cases of T3 as T2. Among the 16 enlarged lymph nodes larger than 8mm, 13 cases were positive on pathologic examination and the sensitivity was 65%. With three-phase spiral CT scanning, we obtained 71% accuracy of depth of tumor invasion. The venous phase is most useful for tumor detection and for determining depth of tumor invasion and lymph node metastasis

  10. CT and MR imaging characteristics of infantile hepatic hemangioendothelioma

    International Nuclear Information System (INIS)

    Feng Shiting; Chan Tao; Ching, A.S.C.; Sun Canhui; Guo Huanyi; Fan Miao; Meng Quanfei; Li Ziping

    2010-01-01

    Aim: This study aims to analyze computed tomography (CT) and magnetic resonance (MR) imaging features of infantile hepatic hemangioendotheliomas before and after treatment. Materials and methods: CT and MR examinations of seven infants with biopsy proven hepatic hemangioendotheliomas were retrospectively analyzed. The distribution, number, size, imaging appearance, enhancement pattern and post-treatment changes of the tumors were evaluated. Results: A total of 153 hepatic hemangioendotheliomas were detected on CT (111) and MR (42) imaging. In six infants, 109/111 (98.2%) tumors were hypodense and 2/111 (1.8%) lesions contained calcification on unenhanced CT. On MR imaging, all 42 lesions in one infant were heterogeneously T1-hypointense and T2-hyperintense compared to the normal liver parenchyma. Contrast-enhanced CT and MRI showed peripheral rim (51.6%), uniform (48.4%), fibrillary (33.3%), and nodular (28.8%) contrast enhancement in the hepatic arterial phase. Homogeneous (100%), rim (98.2%) and mixed enhancement patterns were noted in tumors 2.0 cm and 1.0-2.0 cm in diameter respectively in the hepatic arterial phase. In three patients who underwent steroid therapy, follow-up CT examination demonstrated tumor size reduction and increased intra-tumoral calcification in two patients. Conclusion: Infantile hepatic hemangioendotheliomas show some typical imaging features and size-dependent pattern of contrast enhancement on CT and MR imaging, which allow accurate imaging diagnosis and post-treatment evaluation.

  11. Impact of the planning CT scan time on the reflection of the lung tumor motion

    International Nuclear Information System (INIS)

    Kim, Su San; Choi, Eun Kyung; Yi, Byong Yong; Ha, Sung Whan

    2004-01-01

    To evaluate the reflection of tumor motion according to the planning CT scan time. A model of N-shape, which moved along the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T; CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.33 T, and 1.53 T. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery in the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (IQ Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Light Speed, GE Medical System, with a scan time of 0.8 second per slice) were performed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 T, but remained constant above 1.00 T. Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be 100%, CT scans with scan times of 0.33, 0.50, 0.67, and 0.75 T missed the tumor motion by 30, 27, 20, and 7.0% respectively. Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis increased by 6.3, 17, and 23% in the slow CT scans. As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also

  12. Feasibility of perfusion CT technique integrated into conventional {sup 18}FDG/PET-CT studies in lung cancer patients: clinical staging and functional information in a single study

    Energy Technology Data Exchange (ETDEWEB)

    Ippolito, Davide; Capraro, Cristina; Sironi, Sandro [University of Milano-Bicocca, School of Medicine, Milan (Italy); University of Milano-Bicocca, Department of Diagnostic Radiology, H.S. Gerardo Monza, Via Pergolesi 11, Monza, Milan (Italy); Guerra, Luca [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine and PET Unit - Molecular Bioimaging Centre, Monza (Italy); De Ponti, Elena [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Medical Physics, Monza (Italy); Messa, Cristina [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine and PET Unit - Molecular Bioimaging Centre, Monza (Italy); Tecnomed Foundation, University of Milano-Bicocca, Institute for Bioimaging and Molecular Physiology, National Research Council, Milan (Italy)

    2013-02-15

    To assess the additional functional vascular information and the relationship between perfusion measurements and glucose metabolism (SUVmax) obtained by including a perfusion CT study in a whole-body contrast-enhanced PET/CT protocol in primary lung cancer lesions. Enrolled in this prospective study were 34 consecutive patients with a biopsy-proven diagnosis of lung cancer who were referred for contrast-enhanced PET/CT staging. This prospective study was approved by our institutional review board, and informed consent was obtained from all patients. Perfusion CT was performed with the following parameters: 80 kV, 200 mAs, 30 scans during intravenous injection of 50 ml contrast agent, flow rate 5 ml/s. Another bolus of contrast medium (3.5 ml/s, 80 ml, 60-s delay) was administered to ensure a full diagnostic contrast-enhanced CT scan for clinical staging. The perfusion CT data were used to calculate a range of tumour vascularity parameters (blood flow, blood volume and mean transit time), and tumour FDG uptake (SUVmax) was used as a metabolic indicator. Quantitative and functional parameters were compared and in relation to location, histology and tumour size. The nonparametric Kruskal-Wallis rank sum test was used for statistical analysis. A cut-off value of 3 cm was used according to the TNM classification to discriminate between T1 and T2 tumours (i.e. T1b vs. T2a). There were significant perfusion differences (lower blood volumes and higher mean transit time) between tumours with diameter >30 mm and tumours with diameter <30 mm (p < 0.05; blood volume 5.6 vs. 7.1 ml/100 g, mean transit time 8.6 vs. 3.9 s, respectively). Also there was a trend for blood flow to be lower in larger lesions (p < 0.053; blood flow 153.1 vs. 98.3 ml/100 g tissue/min). Significant inverse correlations (linear regression) were found between blood volume and SUVmax in tumours with diameter >30 mm in diameter. Perfusion CT combined with PET/CT is feasible technique that may provide

  13. Effect of reverse cyclic loading on the fracture resistance curve in C(T) specimen

    International Nuclear Information System (INIS)

    Sung Seok, C.; Jin Kim, Y.; Il Weon, J.

    1999-01-01

    Fracture resistance (J-R) curves, which are used for elastic-plastic fracture mechanics analyses, are known to be dependent on the cyclic loading history. The objective of this paper is to investigate the effect of reverse cyclic loading on the J-R curves in C(T) specimens. The effect of two parameters was observed on the J-R curves during the reverse cyclic loading. One was the minimum-to-maximum load ratio (R) and the other was the incremental plastic displacement (δ cycle /δ i ), which is related to the amount of crack growth that occurs in a cycle. Fracture resistance tests on C(T) specimens with varying the load ratio and the incremental plastic displacement were performed, and the test results showed that the J-R curves were decreased with decreasing the load ratio and decreasing the incremental plastic displacement. Direct current potential drop (DCPD) method was used for the detection of crack initiation and crack growth in typical laboratory J-R tests. The values of crack initiation J-integral (J I ) and crack initiation displacement (δ i ) were also obtained by using the DCPD method. (orig.)

  14. Effect of irradiation on human T-cell proliferation: low dose irradiation stimulates mitogen-induced proliferation and function of the suppressor/cytotoxic T-cell subset

    International Nuclear Information System (INIS)

    Gualde, N.; Goodwin, J.S.

    1984-01-01

    Unfractionated human T cells exposed to 10-50 rad of X irradiation incorporated less [ 3 H]thymidine than nonirradiated T cells when subsequently cultured with PHA or Con A. The cytotoxic/suppressor T-cell subset, isolated as either OKT8(+) or OKT4(-) cells, demonstrated significantly enhanced [ 3 H]thymidine incorporation in PHA- or Con A-stimulated cultures after exposure to 10-50 rad, compared to unirradiated cells, while the proliferation of the OKT4(+) helper/inducer subset was inhibited by low dose irradiation. It has been previously reported that approximately 30% of the cytotoxic/suppressor subset also stains with OKM1. When the cytotoxic/suppressor subset was further subdivided into OKT4(-), OKM1(+), and OKT4(-), OKM1(-) cells, proliferation of the OKT4(-), OKM1(+) population was inhibited by exposure to 25 rad while proliferation of the OKT4(-), OKM1(-) population was stimulated. The increase in proliferation of the cytotoxic/suppressor T-cell subset after low dose irradiation is paralleled by an increase in suppressor activity of these cells. T cells exposed to 25 rad and then cultured with Con A for 48 hr caused greater inhibition of IgG production when added to fresh autologous lymphocytes stimulated by pokeweed mitogen than did unirradiated cells. Thus, low dose irradiation enhances both the proliferation and function of the human suppressor T-cell subset

  15. Comparison of radiation doses between newborns and 6-y-old children undergoing head, chest and abdominal CT examinations-A phantom study

    International Nuclear Information System (INIS)

    Sugimoto, N.; Aoyama, T.; Koyama, S.; Yamauchi-Kawaura, C.; Fujii, K.

    2013-01-01

    Radiation doses in paediatric computed tomography (CT) were investigated for various types of recent CT scanners with newborn and 6-y-old phantoms in which silicon-photodiode dosemeters were implanted at various organ positions. In the head, chest and abdominal CT for the newborn phantom, doses for organs within the scan region were 21-40, 3-8 and 3-12 mGy, respectively. The corresponding doses for the child phantom were 20-37, 2-11 and 4-17 mGy, respectively. In the head, chest and abdominal CT, the effective doses were respectively 2.1-3.3, 2.0-6.0 and 2.2-10.0 mSv for the newborn, and 1.0-2.0, 1.2-6.6 and 2.9-11.8 mSv for the child. Radiation doses for the newborn were at the same levels as those for the child, excepting effective doses in head CT for the newborn, which were 1.8 times higher than those for the child. (authors)

  16. The influence of late-stage pupal irradiation and increased irradiated: un-irradiated male ratio on mating competitiveness of the malaria mosquito Anopheles arabiensis Patton.

    Science.gov (United States)

    Helinski, M E H; Knols, B G J

    2009-06-01

    Competitiveness of released males in genetic control programmes is of critical importance. In this paper, we explored two scenarios to compensate for the loss of mating competitiveness after pupal stage irradiation in males of the malaria mosquito Anopheles arabiensis. First, competition experiments with a higher ratio of irradiated versus un-irradiated males were performed. Second, pupae were irradiated just prior to emergence and male mating competitiveness was determined. Males were irradiated in the pupal stage with a partially or fully-sterilizing dose of 70 or 120 Gy, respectively. Pupae were irradiated aged 20-26 h (young) as routinely performed, or the pupal stage was artificially prolonged by cooling and pupae were irradiated aged 42-48 h (old). Irradiated males competed at a ratio of 3:1:1 to un-irradiated males for mates in a large cage design. At the 3:1 ratio, the number of females inseminated by males irradiated with 70 Gy as young pupae was similar to the number inseminated by un-irradiated males for the majority of the replicates. At 120 Gy, significantly fewer females were inseminated by irradiated than by un-irradiated males. The irradiation of older pupae did not result in a significantly improved male mating competitiveness compared to the irradiation of young pupae. Our findings indicate that the loss of competitiveness after pupal stage irradiation can be compensated for by a threefold increase of irradiated males, but only for the partially-sterilizing dose. In addition, cooling might be a useful tool to facilitate handling processes of large numbers of mosquitoes in genetic control programmes.

  17. Special Analysis for the Disposal of the INL Waste Associated with the Unirradiated Light Water Breeder Reactor (LWBR) Waste Stream at the Area 5 Radioactive Waste Management Site

    Energy Technology Data Exchange (ETDEWEB)

    Shott, Gregory [National Security Technologies, LLC, Las Vegas, NV (United States)

    2017-03-21

    This special analysis (SA) evaluates whether the Idaho National Laboratory (INL) Waste Associated with the Unirradiated Light Water Breeder Reactor (LWBR) waste stream (INEL167203QR1, Revision 0) is suitable for shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS) on the Nevada National Security Site (NNSS). Disposal of the INL Waste Associated with the Unirradiated LWBR waste meets all U.S. Department of Energy (DOE) Manual DOE M 435.1-1, “Radioactive Waste Management Manual,” Chapter IV, Section P performance objectives (DOE 1999). The INL Waste Associated with the Unirradiated LWBR waste stream is recommended for acceptance with the condition that the total uranium-233 (233U) inventory be limited to 2.7E13 Bq (7.2E2 Ci).

  18. Mobile CT. Technical aspects of prehospital stroke imaging before intravenous thrombolysis

    International Nuclear Information System (INIS)

    Gierhake, Daniel; Villringer, K.; Fiebach, J.B.; Weber, J.E.; Audebert, H.J.; Charite - Universitaetsmedizin Berlin; Ebinger, M.; Charite - Universitaetsmedizin Berlin

    2013-01-01

    To reduce the time from symptom onset to treatment with tissue plasminogen activator (tPA) in ischemic stroke, an ambulance was equipped with a CT scanner. We analyzed process and image quality of CT scanning during the pilot study regarding image quality and safety issues. The pilot study of a stroke emergency mobile unit (STEMO) ran over a period of 12 weeks on 5 weekdays from 7a. m. to 6:30 p. m. A teleradiological service for the justifying indication and reporting was established. The radiographer was responsible for the performance of the CT scan on the ambulance. 64 cranial CT scans and 1 intracranial CT angiography were performed. We compared times from ambulance alarm to treatment decision (time of last brain scan) with a cohort of 50 consecutive tPA treatments before implementation of STEMO. 62 (95 %) of the 65 scans performed had sufficient quality for reading. Technical quality was not optimal in 45 cases (69 %) mainly caused by suboptimal positioning of patient or eye lense protection. Motion artefacts were observed in 8 exams (12 %). No safety issues occurred for team or patients. 23 patients were treated with thrombolysis. Time from alarm to last CT scan was 18 minutes shorter than in the tPA cohort before STEMO implementation. A teleradiological support for primary stroke imaging by CT on-site is feasible, quality-wise of diagnostic value and has not raised safety issues. (orig.)

  19. Fundamental role of Methylenetetrahydrofolate Reductase 677 C->T genotype and Flavin compounds in biochemical phenotypes for schizophrenia and schizoaffective psychosis.

    Directory of Open Access Journals (Sweden)

    Stephanie Fryar-Williams

    2016-11-01

    Full Text Available The Mental Health Biomarker Project (2010-2016 explored variables for psychosis in schizophrenia and schizoaffective disorder. Blood samples from 67, highly-characterized symptomatic cases and 67 gender and age matched control participants were analysed for methyl tetrahydrofolate reductase (MTHFR 677C->T gene variants and for vitamin B6, B12 and D, folate, unbound copper, zinc cofactors for enzymes in the methylation cycle and related catecholamine pathways. Urine samples were analysed for indole-catecholamines, their metabolites and oxidative-stress marker, hydroxylpyrolline-2-one (HPL. Rating scales were Brief Psychiatric Rating Scale, Positive and Negative Syndrome Scale, Global Assessment of Function scale, Clinical Global Impression score and Social and Occupational Functioning Scale. Analysis used Spearman’s correlates, Receiver Operating Characteristics and structural equation modelling (SEM. The correlative pattern of variables in the overall participant sample strongly implicated Monoamine Oxidase (MAO enzyme inactivity so the significant role of MAO’s cofactor flavin adenine nucleotide (FAD and its precursor flavin adenine mononucleotide (FMN within the biochemical pathways was investigated and confirmed as 70% on SEM of the total sample. Splitting the data sets for MTHFR 677C->T polymorphism variants coding for the MTHFR enzyme, discovered that biochemistry variables relating to the wild-type enzyme differed markedly in pattern from those coded by the homozygous variant and that the hereozygous-variant pattern resembled the wild type-coded pattern. The MTHFR 677C->T -wild and -heterozygous gene variants have a pattern of depleted vitamin cofactors characteristic of flavin insufficiency with under-methylation and severe oxidative stress. The second homozygous MTHFR 677TT pattern related to elevated copper:zinc ratio and a vitamin pattern related to flavin sufficiency and risk of over-methylation. The two gene variants and their

  20. Estimates of effective dose in adult CT examinations

    International Nuclear Information System (INIS)

    Mohamed, Mustafa Awad Elhaj.

    2015-12-01

    The goal of study was to estimate effective dose (E) in adult CT examinations for Toshiba X64 slice using CT. Exp version 2.5 software in Sudan. Using of CT in medical diagnosis delivers radiation doses to patients that are higher than those from other radiological procedures. lack of optimized protocols could be an additional source of increased dose in developing countries. In order to achieve these objectives, data of CT-scanner has been collected from three hospitals ( ANH, ZSH and MMH). Data collected included equipment information and scan parameters for individual patients, who were used to asses. 300 adult patients underwent head, chest, abdomen-pelvis and peivis CT examinations. The CT1_w , CTD1_vol, DLP, patient effective dos and organ doses were estimated, using CT exposure parameters and CT Exp version 2.5 software. A large variation of mean effective dose and organ doses among hospitals was observed for similar CT examinations. These variations largely originated from different CT scanning protocols used in different hospitals and scan length. The mean effective dose in this study in the Brain, PNS, Chest, pulmonary, Abdomen-pelvis, Pelvis, KUB and CTU were 3.2 mSv, 2.6 mSv, 18.9 mSv 17.6 mSv 27.1 mSv, 11.2 mSv, 9.6 mSv and 23.7 mSv respectively, and organ equivalent, doses presented in this study in this study for the eye lens (for head), lungs and thymus ( for chest) , liver, kidney and small intest ( for abdomen t-pelvis), bladder, uterus and gonads ( for pelvis), were 62.9 mSv, 39.5 mSv, 34.1 mSv, 53.9 mSv, 52.6 mSv, 58.1 mSv, 37 mSv, and 34.6 mSv, respectively. These values were mostly comparable to and slightly higher than the values of effective doses reported from similar studies the United Kingdom, Tanzania, Australia, Canada and Sudan. It was concluded that patient effective dose and organ doses could be substantially minimized through careful selection of scanning parameters based on clinical indications of study, patient size, and body

  1. Special Analysis for the Disposal of the Idaho National Laboratory Unirradiated Light Water Breeder Reactor Rods and Pellets Waste Stream at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-08-31

    The purpose of this special analysis (SA) is to determine if the Idaho National Laboratory (INL) Unirradiated Light Water Breeder Reactor (LWBR) Rods and Pellets waste stream (INEL103597TR2, Revision 2) is suitable for disposal by shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS). The INL Unirradiated LWBR Rods and Pellets waste stream consists of 24 containers with unirradiated fabricated rods and pellets composed of uranium oxide (UO2) and thorium oxide (ThO2) fuel in zirconium cladding. The INL Unirradiated LWBR Rods and Pellets waste stream requires an SA because the 229Th, 230Th, 232U, 233U, and 234U activity concentrations exceed the Nevada National Security Site (NNSS) Waste Acceptance Criteria (WAC) Action Levels.

  2. The Impact of Polymorphic Variations in the 5p15, 6p12, 6p21 and 15q25 Loci on the Risk and Prognosis of Portuguese Patients with Non-Small Cell Lung Cancer

    Science.gov (United States)

    de Mello, Ramon Andrade; Ferreira, Mónica; Soares-Pires, Filipa; Costa, Sandra; Cunha, João; Oliveira, Pedro; Hespanhol, Venceslau; Reis, Rui Manuel

    2013-01-01

    Introduction Polymorphic variants in the 5p15, 6p12, 6p21, and 15q25 loci were demonstrated to potentially contribute to lung cancer carcinogenesis. Therefore, this study was performed to assess the role of those variants in non-small cell lung cancer (NSCLC) risk and prognosis in a Portuguese population. Materials and Methods Blood from patients with NSCLC was prospectively collected. To perform an association study, DNA from these patients and healthy controls were genotyped for a panel of 19 SNPs using a Sequenom® MassARRAY platform. Kaplan-Meier curves were used to assess the overall survival (OS) and progression-free survival (PFS). Results One hundred and forty-four patients with NSCLC were successfully consecutively genotyped for the 19 SNPs. One SNP was associated with NSCLC risk: rs9295740 G/A. Two SNPs were associated with non-squamous histology: rs3024994 (VEGF intron 2) T/C and rs401681 C/T. Three SNPs were associated with response rate: rs3025035 (VEGF intron 7) C/T, rs833061 (VEGF –460) C/T and rs9295740 G/A. One SNP demonstrated an influence on PFS: rs401681 C/T at 5p15, p = 0.021. Four SNPs demonstrated an influence on OS: rs2010963 (VEGF +405 G/C), p = 0.042; rs3025010 (VEGF intron 5 C/T), p = 0.047; rs401681 C/T at 5p15, p = 0.046; and rs31489 C/A at 5p15, p = 0.029. Conclusions Our study suggests that SNPs in the 6p12, 6p21, and 5p15 loci may serve as risk, predictive and prognostic NSCLC biomarkers. In the future, SNPs identified in the genomes of patients may improve NSCLC screening strategies and therapeutic management as well. PMID:24039754

  3. N1303K (c.3909C>G) Mutation and Splicing: Implication of Its c.[744-33GATT(6); 869+11C>T] Complex Allele in CFTR Exon 7 Aberrant Splicing

    Science.gov (United States)

    Farhat, Raëd; Puissesseau, Géraldine; El-Seedy, Ayman; Pasquet, Marie-Claude; Adolphe, Catherine; Corbani, Sandra; Megarbané, André; Kitzis, Alain; Ladeveze, Véronique

    2015-01-01

    Cystic Fibrosis is the most common recessive autosomal rare disease found in Caucasians. It is caused by mutations on the Cystic Fibrosis Transmembrane Conductance Regulator gene (CFTR) that encodes a protein located on the apical membrane of epithelial cells. c.3909C>G (p.Asn1303Lys, old nomenclature: N1303K) is one of the most common worldwide mutations. This mutation has been found at high frequencies in the Mediterranean countries with the highest frequency in the Lebanese population. Therefore, on the genetic level, we conducted a complete CFTR gene screening on c.3909C>G Lebanese patients. The complex allele c.[744-33GATT(6); 869+11C>T] was always associated with the c.3909C>G mutation in cis in the Lebanese population. In cellulo splicing studies, realized by hybrid minigene constructs, revealed no impact of the c.3909C>G mutation on the splicing process, whereas the associated complex allele induces minor exon skipping. PMID:26075213

  4. SU-D-213AB-05: Commissioning a CT Compatible LDR T&O Applicator Using Analytical Calculation with ID and 3D Dosimetry.

    Science.gov (United States)

    Adamson, J; Newton, J; Steffey, B; Cai, J; Adamovics, J; Oldham, M; Chino, J; Craciunescu, O

    2012-06-01

    To determine the characteristics of a new commercially available CT-compatible LDR Tandem and Ovoid (T&O) applicator using 3D dosimetry. We characterized source attenuation through the asymmetric gold shielding in the buckets by measuring dose with diode and 3D dosimetry and compared to an analytical line integral calculation. For 3D dosimetry, a cylindrical PRESAGE dosimeter (9.5cm diameter, 9.2cm height) with a central 6mm channel bored for source placement was scanned with the Duke Large field of view Optical CT-Scanner (DLOS) before and after delivering a nominal 7.7Gy at a distance of 1 cm using a Cs-137 source loaded in the bucket. The optical CT scan time lasted approximately 15 minutes during which 720 projections were acquired at 0.5° increments, anda 3D dose distribution was reconstructed with a 0.5mm 3 isotropic voxel size. The 3D dose distribution was applied to a CT-based T&O implant to determine effect of ovoid shielding on the dose delivered to ICRU 38 Point A as well as D2cc of the bladder, rectum, bowel, and sigmoid. Dose transmission through the gold shielding at a radial distance of 1-3cm from midplane of the source was 86.6%, 86.1, and 87.0% for analytical calculation, diode, and 3D dosimetry, respectively. For the gold shielding of the bucket, dose transmission calculated using the 3D dosimetrymeasurement was found to be lowest at oblique angles from the bucket witha minimum of ∼51%. For the patient case, attenuation from the buckets leadto a decrease in average Point A dose of ∼4% and decrease in D2cc to bladder, rectum, sigmoid, and bowel of 2%, 15%, 2%, and 7%, respectively. The measured 3D dose distribution provided unique insight to the dosimetry and shielding characteristics of the investigated applicator, the technique for which can be applied to commissioning of other brachytherapy applicators. John Adamovics is the owner of Heuris Pharma LLC. Partially supported by NIH Grant R01 CA100835-01. © 2012 American Association of

  5. Staging of gastric adenocarcinoma using two-phase spiral CT: correlation with pathologic staging

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Lee, Dong Ho; Ko, Young Tae; Lim, Joo Won

    1998-01-01

    To correlate the preoperative staging of gastric adenocarcinoma using two-phase spiral CT with pathologic staging. One hundred and eighty patients with gastric cancers confirmed during surgery underwent two-phase spiral CT, and were evaluated retrospectively. CT scans were obtained in the prone position after ingestion of water. Scans were performed 35 and 80 seconds after the start of infusion of 120mL of non-ionic contrast material with the speed of 3mL/sec. Five mm collimation, 7mm/sec table feed and 5mm reconstruction interval were used. T-and N-stage were determined using spiral CT images, without knowledge of the pathologic results. Pathologic staging was later compared with CT staging. Pathologic T-stage was T1 in 70 cases(38.9%), T2 in 33(18.3%), T3 in 73(40.6%), and T4 in 4(2.2%). Type-I or IIa elevated lesions accouted for 10 of 70 T1 cases(14.3%) and flat or depressed lesions(type IIb, IIc, or III) for 60(85.7%). Pathologic N-stage was NO in 85 cases(47.2%), N1 in 42(23.3%), N2 in 31(17.2%), and N3 in 22(12,2%). The detection rate of early gastric cancer using two-phase spiral CT was 100.0%(10 of 10 cases) among elevated lesions and 78.3%(47 of 60 cases) among flat or depressed lesions. With regard to T-stage, there was good correlation between CT image and pathology in 86 of 180 cases(47.8%). Overstaging occurred in 23.3%(42 of 180 cases) and understaging in 28.9%(52 of 180 cases). With regard to N-stage, good correlation between CT image and pathology was noted in 94 of 180 cases(52.2%). The rate of understaging(31.7%, 57 of 180 cases) was higher than that of overstaging(16.1%, 29 of 180 cases)(p<0.001). The detection rate of early gastric cancer using two-phase spiral CT was 81.4%, and there was no significant difference in detectability between elevated and depressed lesions. Two-phase spiral CT for determing the T-and N-stage of gastric cancer was not effective;it was accurate in abont 50% of cases understaging tended to occur.=20

  6. Influence of Preoperative Chemoradiotherapy on the Surgical Strategy According to the Clinical T Stage of Patients With Rectal Cancer

    Science.gov (United States)

    Park, In Ja; Lee, Jong Lyul; Yoon, Yong Sik; Kim, Chan Wook; Lim, Seok-Byung; Lee, Jong Seok; Park, Seong Ho; Park, Jin Hong; Kim, Jong Hoon; Yu, Chang Sik; Kim, Jin Cheon

    2015-01-01

    Abstract The aim of this study was to evaluate the pathologic responses and changes to surgical strategies following preoperative chemoradiotherapy (PCRT) in rectal cancer patients according to their clinical T stage (cT). The use of PCRT has recently been extended to less advanced disease. The authors enrolled 650 patients with cT2 to 4 mid and low rectal cancer who received both PCRT and surgical resection. The rate of total regression and the proportion of local excision were compared according to the cT category. The 3-year recurrence-free survival (RFS) rate was compared using the log-rank test according to patient cT category, pathologic stage, and type of surgical treatment. Patients with cT2 were older (P = 0.001), predominately female (P = 0.028), and had low-lying rectal cancer (P = 0.008). Pathologic total regression was achieved most frequently in cT2 patients (54% of cT2 versus 17.6% of cT3 versus 8.2% of cT4; P rectal cancer, optimal surgical treatment may be achieved with the tailored use of PCRT. PMID:26717384

  7. PET/CT for staging and follow-up of pediatric nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Cheuk, Daniel K.L. [St Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States); The University of Hong Kong, Department of Paediatrics and Adolescent Medicine, Pokfulam (China); Sabin, Noah D.; Hossain, Moinul; Krasin, Matthew J.; Shulkin, Barry L. [St Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States); Wozniak, Amy [St Jude Children' s Research Hospital, Department of Biostatistics, Memphis, TN (United States); Naik, Mihir [St Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States); University of Texas Health Science Center, Department of Radiation Oncology, San Antonio, TX (United States); Rodriguez-Galindo, Carlos [St Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States); Hematology/Oncology, Dana-Farber Cancer Institute, Boston, MA (United States)

    2012-07-15

    While FDG PET/CT for the evaluation of nasopharyngeal carcinoma (NPC) in adult patients has documented advantages and disadvantages compared with conventional imaging, to our knowledge, no studies of FDG PET/CT for the evaluation of NPC in pediatric patients have been performed. In this investigation, we studied the utility of FDG PET/CT in children with NPC. The study group comprised 18 children with biopsy-proven NPC who underwent FDG PET/CT and MRI (total 38 pairs of images). All baseline and follow-up FDG PET/CT and MRI studies were independently reviewed for restaging of disease. The concordance between FDG PET/CT and MRI in T, N, and overall staging was 29%, 64%, and 43%, respectively. Compared with MRI, FDG PET/CT yielded lower T and overall staging and showed less cervical and retropharyngeal lymphadenopathy. The concordance between follow-up FDG PET/CT and MRI was 79% overall and 100% 9 months after therapy. In patients who achieved complete remission, FDG PET/CT showed disease clearance 3-6 months earlier than MRI. There were no false-positive or false-negative FDG PET/CT scans during follow-up. FDG PET/CT may underestimate tumor extent and regional lymphadenopathy compared with MRI at the time of diagnosis, but it helps to detect metastases and clarify ambiguous findings. FDG PET/CT is sensitive and specific for follow-up and enables earlier determination of disease remission. FDG PET/CT is a valuable imaging modality for the evaluation and monitoring of NPC in pediatric patients. (orig.)

  8. Oxide particle size distribution from shearing irradiated and unirradiated LWR fuels in Zircaloy and stainless steel cladding: significance for risk assessment

    International Nuclear Information System (INIS)

    Davis, W. Jr.; West, G.A.; Stacy, R.G.

    1979-01-01

    Sieve fractionation was performed with oxide particles dislodged during shearing of unirradiated or irradiated fuel bundles or single rods of UO 2 or 96 to 97% ThO 2 --3 to 4% UO 2 . Analyses of these data by nonlinear least-squares techniques demonstrated that the particle size distribution is lognormal. Variables involved in the numerical analyses include lognormal median size, lognormal standard deviation, and shear cut length. Sieve-fractionation data are presented for unirradiated bundles of stainless-steel-clad or Zircaloy-2-clad UO 2 or ThO 2 --UO 2 sheared into lengths from 0.5 to 2.0 in. Data are also presented for irradiated single rods (sheared into lengths of 0.25 to 2.0 in.) of Zircaloy-2-clad UO 2 from BWRs and of Zircaloy-4-clad UO 2 from PWRs. Median particle sizes of UO 2 from shearing irradiated stainless-steel-clad fuel ranged from 103 to 182 μm; particle sizes of ThO 2 --UO 2 , under these same conditions, ranged from 137 to 202 μm. Similarly, median particle sizes of UO 2 from shearing unirradiated Zircaloy-2-clad fuel ranged from 230 to 957 μm. Irradiation levels of fuels from reactors ranged from 9,000 to 28,000 MWd/MTU. In general, particle sizes from shearing these irradiated fuels are larger than those from the unirradiated fuels. In addition, variations in particle size parameters pertaining to samples of a single vendor varied as much as those between different vendors. The fraction of fuel dislodged from the cladding is nearly proportional to the reciprocal of the shear cut length, until the cut length attains some minimum value below which all fuel is dislodged. Particles of fuel are generally elongated with a long-to-short axis ratio usually less than 3. Using parameters of the lognormal distribution deduced from experimental data, realistic estimates can be made of fractions of dislodged fuel having dimensions less than specified values

  9. CT and MRI diagnosis of chondrosarcoma in sinonasal and orbital region

    International Nuclear Information System (INIS)

    Yang Bentao; Wang Zhenchang; Xian Junfang; Zhang Zhengyu; Liu Zhonglin; Lan Baosen

    2006-01-01

    Objective: To investigate the CT and MRI findings of chondrosarcoma in sinonasal and orbital region so as to promote the diagnostic accuracy. Methods: All 12 cases of chondrosarcoma were verified by pathology. CT and MRI findings were analyzed retrospectively. Results: The lesions occurred in sinonasal cavity in 9 cases and in orbit in 3 cases. Pathologically 8 cases were conventional chondrosarcoma, 2 dedifferentiated chondrosarcoma, and 2 mesenchymal chondrosarcoma. On CT, chondrosarcoma revealed oval shape in 2 cases, lobular shape in 6 cases and irregular shape in 4 cases. The lesion showed stippled, ring, nodular, patchy or amorphous calcification. Postcontrast CT showed mild inhomogeneous enhancement in 3 cases. Chondrosarcoma demonstrated well-defined margin in 9 cases and hazy margin in 3 cases. Sinonasal chondrosarcoma revealed bony destruction in 7 cases. Orbital chondrosarcoma showed bony erosion invading ipsilateral frontal region in one case. On MR T 1 WI, conventional and dedifferentiated chondrosarcoma showed hypointense signal compared to brain in 6 cases and isointense signal in 4 cases. On T 2 WI, the lesions showed heterogeneous hyperintense signal in 8 cases and isointense signal in 2 cases with marked hypointense foci. Postcontrast MR imaging demonstrated mild to moderate inhomogeneous enhancement in these cases, and showed peripheral and septal enhancement in 5 cases of conventional chondrosarcoma, showing variegated appearance in 3 cases and honeycomb-like appearance in 2 cases. Mesenchymal chondrosarcoma showed isointense signal on both T 1 WI and T 2 WI, with homogeneous and heterogeneous enhancement in one case, respectively. MRI showed the extent and the associated changes of the lesions more clearly compared to CT. Conclusion: CT is the first modality of choice in the diagnosis of chondrosarcoma in sinonasal and orbital region. The typically peripheral and septal contrast enhancement can also suggest the diagnosis of chondrosarcoma on

  10. The diagnosis of MR and CT scan for myofascitis of connective tissue disease: comparison with biopsy examination

    International Nuclear Information System (INIS)

    Xu Jianrong; Zhou Yan; Chai Weimin; Yao Qiuying; Li Lei; Li Lan; Li Zhengyang

    2002-01-01

    Objective: To evaluate the utility of MRI, CT and biopsy examinations in detecting myofascitis lesions of connective tissue disease. Methods: The study group consisted of 22 patients proven by clinical features and laboratory examination, including 8 cases of dermatomyositis (DM), 12 cases of polymyositis (PM), and 2 cases of eosinophilic fascitis. All patients received CT scan, SE-T 1 WI, SE-T 2 WI, SPIR, and CT guiding biopsy at the thigh region. Results: Biopsy detected muscular diseases in 17 cases and fascitis in 5 cases. MRI detected muscular diseases in 14 and fascitis in 9. CT detected muscular diseases in 5 and fascitis in 9. Myositis, amyotrophy, and fascitis may be alone or united in one case. Myositis (9 cases) appeared as low signal on T 1 WI and high signal on T 2 WI or SPIR. Amyotrophy (9 cases) presented hyperintensity on both T 1 WI and T 2 WI. SPIR was more sensitive in detecting myositis than CT and T 1 WI, P < 0.05. Myositis was more frequent in cases with DM(6/8) than in cases with PM (3/12), P < 0.05. Also, myositis was more frequently encountered in active phase (7/11) than in quiescent phase (2/11). Conclusion: MRI and CT appear to be valuable in quantitatively and qualitatively estimating myofascitis of connective tissue diseases

  11. Struma ovarii. MR and CT appearance

    International Nuclear Information System (INIS)

    Joja, Ikuo; Mitsumori, Akihito; Hiraki, Yoshio; Kudo, Takafumi; Nakagawa, Tomio; Asakawa, Toru; Ando, Masaaki; Akamatsu, Nobuo.

    1997-01-01

    The purpose of this study was to examine the appearance of struma ovarii on MR and CT images. All 13 patients showed both cystic and solid components with a multilobulated surface and thickened septa. Various signal intensities were seen on both T1WI and T2WI. The cystic component, which showed low signal intensity on T2WI, showed high density on CT images. The characteristic MR and CT appearance of struma ovarii appears to be that of multicystic tumor indicating the presence of viscid materials containing iodine. (author)

  12. Can lymphovascular invasion be predicted by preoperative multiphasic dynamic CT in patients with advanced gastric cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Zelan; Liang, Cuishan; Huang, Xiaomei; Liu, Zaiyi [Southern Medical University, Guangzhou, Guangdong (China); Guangdong General Hospital, Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Liang, Changhong; Huang, Yanqi [Guangdong General Hospital, Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); He, Lan [Guangdong General Hospital, Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); South China University of Technology, School of Medicine, Guangzhou, Guangdong (China); Chen, Xin [The Affiliated Guangzhou First People' Hospital, Guangzhou Medical University, Department of Radiology, Guangzhou, Guangdong (China); Xiong, Yabing [Southern Medical University, Guangzhou, Guangdong (China)

    2017-08-15

    To determine whether multiphasic dynamic CT can preoperatively predict lymphovascular invasion (LVI) in advanced gastric cancer (AGC). 278 patients with AGC who underwent preoperative multiphasic dynamic CT were retrospectively recruited. Tumour CT attenuation difference between non-contrast and arterial (Δ{sub AP}), portal (Δ{sub PP}) and delayed phase (Δ{sub DP}), tumour-spleen attenuation difference in the portal phase (Δ{sub T-S}), tumour contrast enhancement ratios (CERs), tumour-to-spleen ratio (TSR) and tumour volumes were obtained. All CT-derived parameters and clinicopathological variables associated with LVI were analysed by univariate analysis, followed by multivariate and receiver operator characteristics (ROC) analysis. Associations between CT predictors for LVI and histopathological characteristics were evaluated by the chi-square test. Δ{sub PP} (OR, 1.056; 95% CI: 1.032-1.080) and Δ{sub T-S} (OR, 1.043; 95% CI: 1.020-1.066) are independent predictors for LVI in AGC. Δ{sub PP}, Δ{sub T-S} and their combination correctly predicted LVI in 74.8% (AUC, 0.775; sensitivity, 88.6%; specificity, 54.1%), 68.7% (AUC, 0.747; sensitivity, 68.3%; specificity, 69.4%) and 71.7% (AUC, 0.800; sensitivity, 67.6%; specificity, 77.8%), respectively. There were significant associations between CT predictors for LVI with tumour histological differentiation and Lauren classification. Multiphasic dynamic CT provides a non-invasive method to predict LVI in AGC through quantitative enhancement measurement. (orig.)

  13. CT scout films: Don't forget to look

    International Nuclear Information System (INIS)

    Emamian, Seyed A.; Dubovsky, Elizabeth C.; Vezina, L. Gilbert; Bulas, Dorothy I.; Carter, William

    2003-01-01

    A lateral scout view of the head is always obtained when performing head computed tomography (CT). It is common knowledge that viewing the lateral scout view may provide additional information. For a variety of reasons, however, a careful review may not be performed routinely. To illustrate the value of the lateral scout view, we present a series of representative cases. Six patients with clinically relevant findings on the scout view. Most of the ancillary findings were in the upper cervical spine/neck, which is typically included on the lateral scout view. Careful evaluation of the scout view of the head CT, including the skull and neck, may yield valuable information, which may not be visualized on the axial CT images. (orig.)

  14. CT quantification of lung and airways in normal Korean subjects

    International Nuclear Information System (INIS)

    Kim, Song Soo; Lee, Jeong Eun; Shin, Hye Soo; Jin, Gong Yong; Li, Yuan Zhe

    2017-01-01

    To measure and compare the quantitative parameters of the lungs and airways in Korean never-smokers and current or former smokers (“ever-smokers”). Never-smokers (n = 119) and ever-smokers (n = 45) who had normal spirometry and visually normal chest computed tomography (CT) results were retrospectively enrolled in this study. For quantitative CT analyses, the low attenuation area (LAA) of LAA_I_-_9_5_0, LAA_E_-_8_5_6, CT attenuation value at the 15th percentile, mean lung attenuation (MLA), bronchial wall thickness of inner perimeter of a 10 mm diameter airway (Pi10), total lung capacity (TLC_C_T), and functional residual capacity (FRC_C_T) were calculated based on inspiratory and expiratory CT images. To compare the results between groups according to age, sex, and smoking history, independent t test, one way ANOVA, correlation test, and simple and multiple regression analyses were performed. The values of attenuation parameters and volume on inspiratory and expiratory quantitative computed tomography (QCT) were significantly different between males and females (p < 0.001). The MLA and the 15th percentile value on inspiratory QCT were significantly lower in the ever-smoker group than in the never-smoker group (p < 0.05). On expiratory QCT, all lung attenuation parameters were significantly different according to the age range (p < 0.05). Pi10 in ever-smokers was significantly correlated with forced expiratory volume in 1 second/forced vital capacity (r = −0.455, p = 0.003). In simple and multivariate regression analyses, TLC_C_T, FRC_C_T, and age showed significant associations with lung attenuation (p < 0.05), and only TLC_C_T was significantly associated with inspiratory Pi10. In Korean subjects with normal spirometry and visually normal chest CT, there may be significant differences in QCT parameters according to sex, age, and smoking history

  15. Appendiceal diameter: CT versus sonographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orscheln, Emily S. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati, OH (United States); Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-03-15

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  16. Appendiceal diameter: CT versus sonographic measurements

    International Nuclear Information System (INIS)

    Orscheln, Emily S.; Trout, Andrew T.

    2016-01-01

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  17. Tensile properties of neutron irradiated solid HIP 316L(N). ITER Task T214, NET deliverable GB6 ECN-5

    International Nuclear Information System (INIS)

    Van Osch, E.V.; Tjoa, G.L.; Boskeljon, J.; Van Hoepen, J.

    1998-05-01

    The tensile properties of neutron irradiated Hot Isostatically Pressed (HIP) joints of type 316L(N) stainless steel (heat PM-130) have been measured. Cylindrical tensile test specimens of 4 mm diameter were irradiated in the High Flux Reactor (HFR) in Petten, The Netherlands, simulating the first wall conditions by a combination of high displacement damage with proportional amounts of helium. The solid HIP specimens were irradiated up to a target dose level of 5 dpa at a temperature of 550K. The damage levels realized range from 3.0 to 4.1 dpa, with helium contents up to 38 appm. Post irradiation testing temperatures ranged from 300 to 700K. The report contains the experimental conditions and summarises the results, which are given in terms of engineering stresses and strains and reduction of area. The main conclusions are that the unirradiated solid-HIP material is very soft, assumingly due to the relatively large grain size. Neutron irradiation induces both hardening and reduction of ductility, similar to the behaviour of 316L(N) plate. No failures related to debonding were observed for the tests of the unirradiated samples, however one of eight tested irradiated specimens fractured in the HIP joint, showing a flat fracture surface and a low reduction of area. 6 refs

  18. (D47N) in GJA8 and c.2036C>T in FYCO1 Gene in an Extended

    Indian Academy of Sciences (India)

    user

    Variation c.2036C>T in FYCO1 was not associated with disease in the family. .... without pulverisation pulverulent opacities and other ophthalmic symptoms by .... Genome-wide association study of celiac disease in north america confirms.

  19. The lactase -13910C>T polymorphism (rs4988235) is associated with overweight/obesity and obesity-related variables in a population sample of Portuguese young adults.

    Science.gov (United States)

    Manco, L; Dias, H; Muc, M; Padez, C

    2017-01-01

    Several studies reported associations of the lactase gene (LCT) polymorphism -13910C>T (rs4988235) with obesity-related variables and obesity in adults. This study aimed to replicate previously reported associations in a population sample of Portuguese young adults. We genotyped 447 subjects from central and northern regions of Portugal (mean age 20.81±4.24 years) for the lactase variant -13910C>T (rs4988235), using TaqMan probes. Anthropometric variables (weight, height and body fat) were measured using standardized procedures and body mass index (BMI) (kg/m 2 ) was calculated. Frequency of genotypes was 35.8% CC (lactase nonpersistent, LNP), 48.1% CT and 16.1% TT, consistent with Hardy-Weinberg equilibrium (P=1). The frequency for the minor -13910 T allele was 0.402. Assuming a dominance model for the lactase persistence (LP) minor T-allele, linear regression models showed statistically significant associations between the LP genotype CT/TT and BMI, fat mass and weight (β=1.114, P=0.003; β=1.309, P=0.007 and β=2.67, P=0.021, respectively) after adjustment for age and sex. In concordance, logistic regression showed significant association between LP genotype CT/TT and overweight/obesity (OR=1.77; CI 1.08-2.92; P=0.023), as well as with high fat percentage ranges (OR=1.58; CI 1.01-2.46; P=0.041), when adjusting for age and sex. No significant interaction was obtained between the LCT polymorphism and physical activity for BMI (P int =0.454) or FAT % (P int =0.421). In the Portuguese sample of young adults, the lactase -13910C>T polymorphism revealed significant associations with the obesity-related anthropometric variables BMI, fat mass and weight, and previously observed associations with the obesity risk were also confirmed.

  20. Strong association of 677 C>T substitution in the MTHFR gene with male infertility--a study on an indian population and a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Nishi Gupta

    Full Text Available Methylenetetrahydrofolate reductase (MTHFR is an important enzyme of folate and methionine metabolism, making it crucial for DNA synthesis and methylation. The objective of this study was to analyze MTHFR gene 677C>T polymorphism in infertile male individuals from North India, followed by a meta-analysis on our data and published studies.We undertook genotyping on a total of 837 individuals including well characterized infertile (N = 522 and confirmed fertile (N = 315 individuals. The SNP was typed by direct DNA sequencing. Chi square test was done for statistical analysis. Published studies were searched using appropriate keywords. Source of data collection for meta-analysis included 'Pubmed', 'Ovid' and 'Google Scholar'. Those studies analyzing 677C>T polymorphism in male infertility and presenting all relevant data were included in meta-analysis. The genotype data for infertile subjects and fertile controls was extracted from each study. Chi square test was done to obtain odds ratio (OR and p-value. Meta-analysis was performed using Comprehensive Meta-analysis software (Version 2. The frequency of mutant (T allele (p = 0.0025 and genotypes (CT+TT (p = 0.0187 was significantly higher in infertile individuals in comparison to fertile controls in our case-control study. The overall summary estimate (OR for allele and genotype meta-analysis were 1.304 (p = 0.000, 1.310 (p = 0.000, respectively, establishing significant association of 677C>T polymorphism with male infertility.677C>T substitution associated strongly with male infertility in Indian population. Allele and genotype meta-analysis also supported its strong correlation with male infertility, thus establishing it as a risk factor.

  1. Global translational impacts of the loss of the tRNA modification t6A in yeast

    Directory of Open Access Journals (Sweden)

    Patrick C. Thiaville

    2015-12-01

    Full Text Available The universal tRNA modification t6A is found at position 37 of nearly all tRNAs decoding ANN codons. The absence of t6A37 leads to severe growth defects in baker’s yeast, phenotypes similar to those caused by defects in mcm5s2U34 synthesis. Mutants in mcm5s2U34 can be suppressed by overexpression of tRNALysUUU, but we show t6A phenotypes could not be suppressed by expressing any individual ANN decoding tRNA, and t6A and mcm5s2U are not determinants for each other’s formation. Our results suggest that t6A deficiency, like mcm5s2U deficiency, leads to protein folding defects, and show that the absence of t6A led to stress sensitivities (heat, ethanol, salt and sensitivity to TOR pathway inhibitors. Additionally, L-homoserine suppressed the slow growth phenotype seen in t6A-deficient strains, and proteins aggregates and Advanced Glycation End-products (AGEs were increased in the mutants. The global consequences on translation caused by t6A absence were examined by ribosome profiling. Interestingly, the absence of t6A did not lead to global translation defects, but did increase translation initiation at upstream non-AUG codons and increased frame-shifting in specific genes. Analysis of codon occupancy rates suggests that one of the major roles of t6A is to homogenize the process of elongation by slowing the elongation rate at codons decoded by high abundance tRNAs and I34:C3 pairs while increasing the elongation rate of rare tRNAs and G34:U3 pairs. This work reveals that the consequences of t6A absence are complex and multilayered and has set the stage to elucidate the molecular basis of the observed phenotypes.

  2. CT and MRI of vertebral haemangiomas

    International Nuclear Information System (INIS)

    Braitinger, S.; Weigert, F.; Held, P.; Obletter, N.; Breit, A.

    1989-01-01

    A retrospective comparative study of CT and MRI was carried out involving 38 vertebral haemangiomas; this revealed a typical signal pattern on MRI from benign lesions. It consists of a hyper-intense signal from the bone marrow affecting the T 1 /T 2 sequences; this may be focal or involve the entire vertebral body. These characteristic signals were compared with CT images of the spine. The areas of bone that produce the high intensity signals on MRI appear on CT as spongey patterns with hypertrophic trabeculae surrounding mostly areas with negative absorption values. An analysis of the changes in the spongiosa has revealed three clearly defined types. The signals derived from haemangiomas extending beyond the bone have an intensity of normal spongiosa; this corresponds with an absence of fat, as demonstrated by CT. Extra-osseous components have low intensity T 1 signals that increase in T 2 sequences. (orig.) [de

  3. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT; Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2012-05-15

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI{sub vol} values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 {+-} 2.5 vs. 11.4 {+-} 1.4, p < 0.001; 14.2 {+-} 3.7 vs. 16.1 {+-} 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 {+-} 201.1 vs. 849.8 {+-} 90.9, p < 0,001; 504.4 {+-} 134.4 vs. 471.5 {+-} 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 {+-} 35.8 vs. 155.5 {+-} 12.3 (p < 0.001), thorax 427.4 {+-} 44.5 vs. 388.3 {+-} 57.5 (p < 0.001), abdomen 520.3 {+-} 50.2 vs. 490.8 {+-} 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 {+-} 2.6 (4-row MDCT) and 24.1 {+-} 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  4. "6"8Ga-PSMA PET/CT: Joint EANM and SNMMI procedure guideline for prostate cancer imaging: version 1.0

    International Nuclear Information System (INIS)

    Fendler, Wolfgang P.; Eiber, Matthias; Beheshti, Mohsen; Bomanji, Jamshed; Wan, Simon; Ceci, Francesco; Fanti, Stefano; Cho, Steven; Giesel, Frederik; Haberkorn, Uwe; Hope, Thomas A.; Kopka, Klaus; Krause, Bernd J.; Mottaghy, Felix M.; Schoeder, Heiko; Sunderland, John; Wester, Hans-Juergen; Herrmann, Ken

    2017-01-01

    The aim of this guideline is to provide standards for the recommendation, performance, interpretation and reporting of "6"8Ga-PSMA PET/CT for prostate cancer imaging. These recommendations will help to improve accuracy, precision, and repeatability of "6"8Ga-PSMA PET/CT for prostate cancer essentially needed for implementation of this modality in science and routine clinical practice. (orig.)

  5. The 341C/T polymorphism in the GSTP1 gene is associated with increased risk of oesophageal cancer

    Directory of Open Access Journals (Sweden)

    Dandara Collet

    2010-06-01

    Full Text Available Abstract Background The Glutathione S-transferases (GSTs comprise a group of enzymes that are critical in the detoxification of carcinogens. In this study the effects of polymorphisms in these genes on the risk of developing oesophageal squamous cell carcinoma (OSCC were evaluated in a hospital-based case-control study in two South African population groups. Genetic polymorphisms in GSTs were investigated in 245 patients and 288 controls samples by PCR-RFLP analysis. Results The GSTP1 341T variant was associated with significantly increased risk of developing OSCC as observed from the odds ratios for the GSTP1 341C/T and GSTP1 341T/T genotypes (OR = 4.98; 95%CI 3.05-8.11 and OR = 10.9; 95%CI 2.43-49.1, respectively when compared to the homozygous GSTP1 341C/C genotype. The risk for OSCC in the combined GSTP1 341C/T and T/T genotypes was higher in tobacco smokers (OR = 7.51, 95% CI 3.82-14.7, alcohol consumers (OR = 15.3, 95% CI 1.81-12.9 and those using wood or charcoal for cooking and heating (OR = 12.1, 95% CI 3.26-49 when compared to those who did not smoke tobacco, or did not consume alcohol or user other forms of fuel for cooking and heating. Despite the close proximity of the two GSTP1 SNPs (313A>G and 341C>T, they were not in linkage disequilibrium in these two population groups (D':1.0, LOD: 0.52, r2: 0.225. The GSTP1 313A/G polymorphism on the other hand, did not display any association with OSSC. The homozygous GSTT1*0 genotype was associated with increased risk of OSCC (OR = 1.71, 95%CI 1.18-2.46 while the homozygous GSTM1*0 genotype was associated with significantly decreased risk of OSCC in the Mixed Ancestry subjects (OR= 0.39, 95%CI 0.25-0.62. Conclusions This study shows that the risk of developing OSCC in the South African population can be partly explained by genetic polymorphisms in GST coding genes and their interaction with environmental factors such as tobacco smoke and alcohol consumption.

  6. Safety Analysis Report for Packaging: The unirradiated fuel shipping container USA/9853/AF

    International Nuclear Information System (INIS)

    1991-01-01

    The HFBR Unirradiated Fuel Shipping Container was designed and fabricated at the Oak Ridge National Laboratory in 1978 for the transport of fuel for the High Flux Beam Reactor (HFBR) for Brookhaven National Laboratory. The package has been evaluated analytically, as well as the comparison to tests on similar packages, to demonstrate compliance with the applicable regulations governing packages in which radioactive and fissile materials are transported. The contents of this Safety Analysis Report for Packaging (SARP) are based on Regulatory Guide 7.9 (proposed Revision 2 - May 1986), 10 CFR Part 71, DOE Order 1540.2, DOE Order 5480.3, and 49 CFR Part 173

  7. Quantitative 3D ultrashort time-to-echo (UTE) MRI and micro-CTCT) evaluation of the temporomandibular joint (TMJ) condylar morphology

    Energy Technology Data Exchange (ETDEWEB)

    Geiger, Daniel [Sapienza University of Rome, Department of Radiological, Oncological and Pathological Sciences, Rome (Italy); Bae, Won C.; Statum, Sheronda; Du, Jiang; Chung, Christine B. [University of California-San Diego, Department of Radiology, San Diego, CA (United States)

    2014-01-15

    Temporomandibular dysfunction involves osteoarthritis of the TMJ, including degeneration and morphologic changes of the mandibular condyle. The purpose of this study was to determine the accuracy of novel 3D-UTE MRI versus micro-CTCT) for quantitative evaluation of mandibular condyle morphology. Nine TMJ condyle specimens were harvested from cadavers (2 M, 3 F; age 85 ± 10 years, mean ± SD). 3D-UTE MRI (TR = 50 ms, TE = 0.05 ms, 104-μm isotropic-voxel) was performed using a 3-T MR scanner and μCT (18-μm isotropic-voxel) was also performed. MR datasets were spatially registered with a μCT dataset. Two observers segmented bony contours of the condyles. Fibrocartilage was segmented on the MR dataset. Using a custom program, bone and fibrocartilage surface coordinates, Gaussian curvature, volume of segmented regions, and fibrocartilage thickness were determined for quantitative evaluation of joint morphology. Agreement between techniques (MRI vs. μCT) and observers (MRI vs. MRI) for Gaussian curvature, mean curvature, and segmented volume of the bone were determined using intraclass correlation coefficient (ICC) analysis. Between MRI and μCT, the average deviation of surface coordinates was 0.19 ± 0.15 mm, slightly higher than the spatial resolution of MRI. Average deviation of the Gaussian curvature and volume of segmented regions, from MRI to μCT, was 5.7 ± 6.5 % and 6.6 ± 6.2 %, respectively. ICC coefficients (MRI vs. μCT) for Gaussian curvature, mean curvature, and segmented volumes were 0.892, 0.893, and 0.972, respectively. Between observers (MRI vs. MRI), the ICC coefficients were 0.998, 0.999, and 0.997, respectively. Fibrocartilage thickness was 0.55 ± 0.11 mm, as previously described in the literature for grossly normal TMJ samples. 3D-UTE MR quantitative evaluation of TMJ condyle morphology ex-vivo, including surface, curvature, and segmented volume, shows high correlation against μCT and between observers. In addition, UTE MRI allows

  8. CT and MR imaging of the liver. Clinical importance of nutritional status

    International Nuclear Information System (INIS)

    Leander, P.; Sjoeberg, S.; Hoeglund, P.

    2000-01-01

    Purpose: In an experimental study in rats a correlation between nutritional status and hepatic attenuation in CT and signal intensities in MR imaging was shown. Is physiological nutritional status of importance in clinical CT and MR imaging? Material and methods: In a cross-over study including 12 healthy volunteers (6 women and 6 men, mean age 34 years), CT and MR imaging of the liver were performed with nutritional status at three different levels, i.e., normal, fasting and after glycogen-rich meals. CT and MR were performed on clinical imaging systems and hepatic attenuation and signal intensity, respectively, were assessed. In MR, T1-weighted, proton density-weighted and T2-weighted pulse-sequences were used. Results: In CT there were significantly (p<0.01) higher liver attenuations in normal nutritional status and after glycogen rich-meals compared to the fasting condition. The difference between fasting and glycogen-rich meals were 10.5 HU for men, 7.4 for women and mean 8.8 HU for all 12 volunteers. In MR imaging the differences were small and non-significant. The results of this study are in accordance with an earlier experimental study in rats. Conclusion: In CT it may be of importance not to have patients in a fasting condition as it lowers the attenuation in normal liver tissue. The findings are important for planning of clinical studies where hepatic attenuation will be assessed and may be of some importance in clinical CT. In MR imaging the results indicate that the nutritional status is of less importance

  9. Perforated appendicitis: accuracy of CT diagnosis and correlation of CT findings with the length of hospital

    International Nuclear Information System (INIS)

    Siddiqui, H.A.; Afzal, S.

    2007-01-01

    To determine the sensitivity and specificity of CT findings in the differentiation of perforated from nonperforated appendicitis and correlate CT diagnosis with the length of hospital stay. The study included 70 patients who presented with right lower quadrant abdominal pain and underwent preoperative CT scan followed by appendectomy. Patients were divided into two groups of having perforated and nonperforated appendicitis on the basis of CT scan findings. The surgical and pathological reports combined were considered the reference standard for the diagnosis of perforated appendicitis. Various CT scan findings and average duration of hospital stay in days was compared by t-test. Twenty-six (37%) of 70 patients had perforated appendicitis. It was correctly identified on pre-operative CT scan in 18 patients. There were 18 true positive diagnoses, 43 true negative diagnoses, 1 false positive diagnosis and 8 false negative diagnoses which yielded a sensitivity of 69%, specificity of 97%, positive predictive value of 94% and negative predictive value of 84%. Mean length of hospital stay in perforated group was 6.3 days and 2.9 days in nonperforated group. Severe periappendiceal inflammation, periappendiceal and or abdominopelvic fluid and abscess were significantly associated with perforated appendicitis and with a significant longer hospital stay (p <.001). CT scan is 69% sensitive and 97% specific for the diagnosis of perforated appendicitis and constellation of CT findings can be used to select patients with perforated appendicitis for initial non-operative management. Presence of CT signs of significant appendiceal inflammation is independent predictor of longer hospital stay. (author)

  10. Value of MR imaging after CT in patients with focal hepatic lesion

    International Nuclear Information System (INIS)

    Kim, Kyeong Ah; Lim, Jae Hoon; Choi, Sang Hee; Lee, Soon Jin; Paik, Chul H.; Cho, Jae Min

    1999-01-01

    To determine the usefulness of magnetic resonance imaging (MRI) after computed tomography (CT) in patients with focal hepatic lesion. We evaluated 100 patients with 103 focal hepatic lesions. The diagnosis of each lesion was made pathologically (n=19), or radiologically and clinically (n=84), and the findings were as follows : hemangioma (n=53), hepatocellular carcinoma (n=17), metastasis (n=10), cyst (n=5), regenerative nodule (n=3), and adenomatous hyperplasia (n=3). The patients underwent conventional CT (n=25), two-phase spiral CT (n=17) or three-phase spiral CT (n=61). MRI was performed using conventional T1- and T2-weighted imaging and dynamic contrast enhancement. The value of MRI after CT was assigned to one of four grades, according to the consensus of three radiologists : grade I (decisive), grade II (helpful), grade III (not additional), or grade IV (confused). The outcome of MRI of 103 lesions was grade I in 14 cases(14%), II in 34 (33%), III in 49 (48%), and IV in 6 (6%). MRI was not helpful (grade III or IV) in 40% (10/25), 47% (8/17), and 61%(31/61) of lesions after conventional, two-phase spiral, and three-phase spiral CT, respectively. Grade III or IV lesions were present in 45% of hemangiomas (24/53), 59% of hepatocellular carcinomas (10/17), and 80% of cases in which metastasis had occurred(8/10). MRI after CT in patients with focal hepatic lesion was helpful in less than half of all cases. It was particularly valuable for patients who did not undergo three-phase spiral CT and in whom hemangioma was suspected

  11. Plakophilin-2 c.419C>T and risk of heart failure and arrhythmias in the general population

    DEFF Research Database (Denmark)

    Christensen, Alex Hørby; Kamstrup, Pia Rørbœk; Gandjbakhch, Estelle

    2016-01-01

    A rare genetic variant in the desmosomal gene plakophilin-2 (PKP2) c.419C>T(p.(S140F)) has repeatedly been identified in patients with dilated cardiomyopathy (DCM) and arrhythmogenic right ventricular cardiomyopathy (ARVC). Whether this is a disease-causing variant remains highly controversial. We...... ratios as a function of c.419C>T genotype were 2.11 (0.50-8.99) for ARVC, 0.72 (0.16-3.28) for hypertrophic cardiomyopathy (HCM)/DCM, and 1.28 (0.46-3.54) for end points combined. Third, in in vitro studies cellular localization of plakophilin-2, plakoglobin, connexin-43, or N-cadherin were similar...... in cells transfected with wild-type or mutant plakophilin-2. In conclusion, combining epidemiological data, with data on patients referred for genetic testing for ARVC or HCM/DCM, and data from in vitro studies, PKP2 c.419C>T did not associate with heart failure, arrhythmias, or premature death, with ARVC...

  12. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: A comparison of CT and CT-MRI based tissue segmentation on simulated temperature

    International Nuclear Information System (INIS)

    Verhaart, René F.; Paulides, Margarethus M.; Fortunati, Valerio; Walsum, Theo van; Veenland, Jifke F.; Verduijn, Gerda M.; Lugt, Aad van der

    2014-01-01

    Purpose: In current clinical practice, head and neck (H and N) hyperthermia treatment planning (HTP) is solely based on computed tomography (CT) images. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast over CT. The purpose of the authors’ study is to investigate the relevance of using MRI in addition to CT for patient modeling in H and N HTP. Methods: CT and MRI scans were acquired for 11 patients in an immobilization mask. Three observers manually segmented on CT, MRI T1 weighted (MRI-T1w), and MRI T2 weighted (MRI-T2w) images the following thermo-sensitive tissues: cerebrum, cerebellum, brainstem, myelum, sclera, lens, vitreous humor, and the optical nerve. For these tissues that are used for patient modeling in H and N HTP, the interobserver variation of manual tissue segmentation in CT and MRI was quantified with the mean surface distance (MSD). Next, the authors compared the impact of CT and CT and MRI based patient models on the predicted temperatures. For each tissue, the modality was selected that led to the lowest observer variation and inserted this in the combined CT and MRI based patient model (CT and MRI), after a deformable image registration. In addition, a patient model with a detailed segmentation of brain tissues (including white matter, gray matter, and cerebrospinal fluid) was created (CT and MRI db ). To quantify the relevance of MRI based segmentation for H and N HTP, the authors compared the predicted maximum temperatures in the segmented tissues (T max ) and the corresponding specific absorption rate (SAR) of the patient models based on (1) CT, (2) CT and MRI, and (3) CT and MRI db . Results: In MRI, a similar or reduced interobserver variation was found compared to CT (maximum of median MSD in CT: 0.93 mm, MRI-T1w: 0.72 mm, MRI-T2w: 0.66 mm). Only for the optical nerve the interobserver variation is significantly lower in CT compared to MRI (median MSD in CT: 0.58 mm, MRI-T1w: 1.27 mm, MRI-T2w: 1.40 mm). Patient

  13. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: A comparison of CT and CT-MRI based tissue segmentation on simulated temperature

    Energy Technology Data Exchange (ETDEWEB)

    Verhaart, René F., E-mail: r.f.verhaart@erasmusmc.nl; Paulides, Margarethus M. [Hyperthermia Unit, Department of Radiation Oncology, Erasmus MC - Cancer Institute, Groene Hilledijk 301, Rotterdam 3008 AE (Netherlands); Fortunati, Valerio; Walsum, Theo van; Veenland, Jifke F. [Biomedical Imaging Group of Rotterdam, Department of Medical Informatics and Radiology, Erasmus MC, Dr. Molewaterplein 50/60, Rotterdam 3015 GE (Netherlands); Verduijn, Gerda M. [Department of Radiation Oncology, Erasmus MC - Cancer Institute, Groene Hilledijk 301, Rotterdam 3008 AE (Netherlands); Lugt, Aad van der [Department of Radiology, Erasmus MC, Dr. Molewaterplein 50/60, Rotterdam 3015 GE (Netherlands)

    2014-12-15

    Purpose: In current clinical practice, head and neck (H and N) hyperthermia treatment planning (HTP) is solely based on computed tomography (CT) images. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast over CT. The purpose of the authors’ study is to investigate the relevance of using MRI in addition to CT for patient modeling in H and N HTP. Methods: CT and MRI scans were acquired for 11 patients in an immobilization mask. Three observers manually segmented on CT, MRI T1 weighted (MRI-T1w), and MRI T2 weighted (MRI-T2w) images the following thermo-sensitive tissues: cerebrum, cerebellum, brainstem, myelum, sclera, lens, vitreous humor, and the optical nerve. For these tissues that are used for patient modeling in H and N HTP, the interobserver variation of manual tissue segmentation in CT and MRI was quantified with the mean surface distance (MSD). Next, the authors compared the impact of CT and CT and MRI based patient models on the predicted temperatures. For each tissue, the modality was selected that led to the lowest observer variation and inserted this in the combined CT and MRI based patient model (CT and MRI), after a deformable image registration. In addition, a patient model with a detailed segmentation of brain tissues (including white matter, gray matter, and cerebrospinal fluid) was created (CT and MRI{sub db}). To quantify the relevance of MRI based segmentation for H and N HTP, the authors compared the predicted maximum temperatures in the segmented tissues (T{sub max}) and the corresponding specific absorption rate (SAR) of the patient models based on (1) CT, (2) CT and MRI, and (3) CT and MRI{sub db}. Results: In MRI, a similar or reduced interobserver variation was found compared to CT (maximum of median MSD in CT: 0.93 mm, MRI-T1w: 0.72 mm, MRI-T2w: 0.66 mm). Only for the optical nerve the interobserver variation is significantly lower in CT compared to MRI (median MSD in CT: 0.58 mm, MRI-T1w: 1.27 mm, MRI-T2w: 1.40 mm

  14. Evaluation of TSE- and T1-3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT

    International Nuclear Information System (INIS)

    Stork, A.; Schulze, D.; Koops, A.; Kemper, J.; Adam, G.

    2002-01-01

    Purpose: Evaluation of TSE- and T 1 -3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT. Materials and methods: Forty artificial cartilage lesions in ten bovine patellae were immersed in a solution of iodinated contrast medium and assessed with ultrahigh resolution multi-slice CT. Fat-suppressed TSE images with intermediate- and T 2 -weighting at a slice thickness of 2, 3 and 4 mm as well as fat-suppressed T 1 -weighted 3D-FLASH images with an effective slice thickness of 1, 2 and 3 mm were acquired at 1.5 T. After adding Gd-DTPA to the saline solution containing the patellae, the T 1 -weighted 3D-FLASH imaging was repeated. Results: All cartilage lesions were visualised and graded with ultrahigh resolution multi-slice CT. The TSE images had a higher sensitivity and a higher inter- and intraobserver kappa compared to the FLASH-sequences (TSE: 70-95%; 0.82-0.83; 0.85-0.9; FLASH: 57.5-85%; 0.53-0.72; 0.73-0.82, respectively). An increase in slice thickness decreased the sensitivity, whereby deep lesions were even reliably depicted on TSE images at a slice thickness of 3 and 4 mm. Adding Gd-DTPA to the saline solution increased the sensitivity by 10% with no detectable advantage over the T 2 -weighted TSE images. Conclusion: TSE sequences and application of Gd-DTPA seemed to be superior to T 1 -weighted 3D-FLASH sequences without Gd-DTPA in the detection of focal cartilage lesions. The ultrahigh resolution multi-slice CT can serve as in vitro reference standard for focal cartilage lesions. (orig.) [de

  15. Thermal studies on unirradiated and γ-irradiated polymer of allyl diglycol carbonate

    International Nuclear Information System (INIS)

    Kalsi, P.C.; Pandey, A.K.; Iyer, R.H.; Singh Mudher, K.D.

    1995-01-01

    The thermal decomposition of unirradiated and γ-irradiated (5.93-15.5 MRad dose range) allyl diglycol carbonate polymer (trade name, CR-39) was studied by thermogravimetry (TG) and differential thermal analysis (DTA). These studies indicate four main decomposition steps in CR-39 polymer in air. Assessment of the influence of radiation dose on the above range shows that while the 5.93 MRad γ-irradiated polymer CR-39 degrades in three steps, the 15.5 MRad γ-irradiated polymer degrades in only two steps. The kinetics of the different stages of degradation were also evaluated from the TG curves. Irradiation enhances the decomposition rate and the effect increases further with increasing radiation dose. The activation energy values calculated for all the decomposition stages decrease on irradiation

  16. The structures of T6, T3R3 and R6 bovine insulin: combining X-ray diffraction and absorption spectroscopy

    DEFF Research Database (Denmark)

    Frankær, Christian Grundahl; Knudsen, Marianne Vad; Noren, Katarina

    2012-01-01

    The crystal structures of three conformations, T6, T3R3 and R6, of bovine insulin were solved at 1.40, 1.30 and 1.80 Å resolution, respectively. All conformations crystallized in space group R3. In contrast to the T6 and T3R3 structures, different conformations of the N-terminal B-chain residue Phe......B1 were observed in the R6 insulin structure, resulting in an eightfold doubling of the unit-cell volume upon cooling. The zinc coordination in each conformation was studied by X-ray absorption spectroscopy (XAS), including both EXAFS and XANES. Zinc adopts a tetrahedral coordination in all R3 sites...... molecules, as well as in other high-resolution insulin structures. As the radiation dose for XRD experiments is two orders of magnitude higher compared with that of XAS experiments, the single crystals were exposed to a higher degree of radiation damage that affected the zinc coordination in the T3 sites...

  17. Diagnostic value of US, CT arthrography, and 0.5-T MR imaging of lesions of the biceps tendon

    International Nuclear Information System (INIS)

    Saez, F.; Elizagaray, E.; Pena, J.M.; Ferrero, A.; Azkuna, I.; Larrea, L.

    1990-01-01

    This paper evaluates the role of US, CT-arthrography, and MR imaging in lesions in the tendon of the long head of the biceps brachii and bicipital groove. One hundred fifty-four patients with painful shoulder were prospectively studied by means of US and axial CT-arthrography, and 45 of them were also examined with 0.5-T MR imaging. Fifty-three (34.4%) patients showed biceps tendon or bicipital groove abnormalities; including 34 bicipital groove bone spurs, 31 cases of tendinitis, eight intraarticular ruptures, four subluxations, and eight medial dislocations

  18. C.T. scanning in the pre-operative assessment of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Goldstraw, P.

    1986-01-01

    The concept of T.N.M. staging is now widely adopted, providing an international shorthand to describe tumour extent. Throughout this article the system referred to is that of the American Joint Committee on Cancer Staging and End Results Reporting. It is generally now accepted that Stage I and II patients with N.S.C.L.C. benefit from pulmonary resection, whilst those with Stage III tumours by virtue of T3 status, N2 disease or M stage other than zero, do not. There are exceptions to this rule and they are discussed in the relevant section. The authors therefore consider the role of C.T. scanning in pre-operative staging under the following headings. Tumour characteristics: 1) indicators of malignancy, 2) extra-pulmonary extension; Nodal metastases: 1) hilar, 2) mediastinal; Metastases to distant sites

  19. Numerical investigation of 3-D constraint effects on brittle fracture in SE(B) and C(T) specimens

    International Nuclear Information System (INIS)

    Nevalainen, M.; Dodds, R.H. Jr.

    1996-07-01

    This investigation employs 3-D nonlinear finite element analyses to conduct an extensive parametric evaluation of crack front stress triaxiality for deep notch SE(B) and C(T) specimens and shallow notch SE(B) specimens, with and without side grooves. Crack front conditions are characterized in terms of J-Q trajectories and the constraint scaling model for cleavage fracture toughness proposed previously by Dodds and Anderson. The 3-D computational results imply that a significantly less strict size/deformation limit, relative to the limits indicated by previous plane-strain computations, is needed to maintain small-scale yielding conditions at fracture by a stress- controlled, cleavage mechanism in deep notch SE(B) and C(T) specimens. Additional new results made available from the 3-D analyses also include revised η-plastic factors for use in experimental studies to convert measured work quantities to thickness average and maximum (local) J-values over the crack front

  20. Clinical studies on thyroid CT number in Graves' disease and destructive thyrotoxicosis

    Energy Technology Data Exchange (ETDEWEB)

    Kamijo, Keiichi (Kamijo Thyroid and Pituitary Clinic, Sapporo (Japan))

    1994-02-01

    The purpose of the present study was to investigate CT Hounsfield unit (H.U.) of the thyroid in hyperthyroid and euthyroid Graves' disease and destructive thyrotoxicosis. The mean thyroid CT number in 95 controls was 122[+-]18 H.U.([+-]SD) and did not change significatly with advancing age. The mean thyroid CT number ([+-]SD) of 85[+-]22 H.U. in 60 patients with hyperthyroid Graves' disease was significantly lower than either in normal controls or 116[+-]22 H.U. in 11 patients with euthyroid Graves' disease. Comparison of thyroid hormones and TSH receptor Ab values of untreated patients with a normal and an abnormally low thyroid CT number showed that serum total and free T[sub 3] were significantly higher in the latter group than the former group. With respect to the effect of methimazol (MMI) on the thyroid CT number, in the untreated 10 patients with a low thyroid CT number, the initial mean CT number was 65[+-]11 H.U. and increased significantly to 76[+-]14 H.U. after treatment with MMI. In contrast, in 6 patients with a normal thyroid CT number prior to therapy, the initial mean thyroid CT number was 102[+-]11 H.U. and fell significantly to 84[+-]16 H.U. after treatment with MMI. The thyroid CT number in destructive thyrotoxicosis is markedly decreased to less than 70 H.U. and the mean values of 57[+-]7 H.U. in 6 patients with silent thyroiditis and of 61[+-]5 H.U. in 7 with subacute thyroiditis differ significantly from Graves' disease. In conclusion, the thyroid CT number is significantly reduced in hyperthyroid Graves' disease, normal in euthyroid Graves' disease and markedly decreased in destructive thyrotoxicosis. The high T-3 value seemed to play an important role in the pathogenesis of a decline in the thyroid CT number in Graves' disease. An antithyroid drug therapy caused two different changes in the thyroid CT number, depending on whether the thyroid CT number prior to therapy was normal or low. (author).

  1. SC*994C>T causes the Sc(null) phenotype in Pacific Islanders and successful transfusion of Sc3+ blood to a patient with anti-Sc3.

    Science.gov (United States)

    Reid, Marion E; Hue-Roye, Kim; Velliquette, Randall W; Larimore, Kathleen; Moscarelli, Sue; Ohswaldt, Nicolas; Lomas-Francis, Christine

    2013-01-01

    Antigens in the SC blood group system are expressed by the human erythrocyte membrane-associated protein (ERMAP).Two molecular bases have been reported for the Sc,un phenotype:SC*307del2 and SC*994C>T. We report our investigation of the molecular background of five Sc,n1 individuals from the Pacific Islands and describe the successful transfusion of Sc3+ blood to a patient with anti-Sc3 in her plasma. SC (ERMAP) exons 2,3, and 12 and their flanking intronic regions were analyzed. TheSC*994C>T change introduces a restriction enzyme cleavage site for Tsp45I, and polymerase chain reaction (PCR) products from exon 12 were subjected to this PCR-restriction fragment length polymorphism (RFLP) assay. The five samples had the variant SC*994T/T. One sample, from a first cousin of one Marshallese proband, was heterozygous for SC*1514C/T (in the 3' untranslated region); the other four samples were SC*1514C/C(consensus sequence). Samples from white donors (n = 100) and African American donors (n = 99) were tested using the Tsp45IPCR-RFLP assay; all gave a banding pattern that was consistent with the SC*994C/C consensus sequence. In all five samples,our analyses showed homozygosity for the nonsense nucleotide change SC*994C>Tin an allele carrying the nucleotide associated with SLd. Further investigation determined that one of the probands reported previously with the SC*994C>T change was from the Marshall Islands (which form part of the Micronesian Pacific Islands) and the other was from an unspecified location within the large collection of Pacific Islands. Taken together, the five known probands with the SC*994C>T silencing nucleotide change were from the Pacific Islands.

  2. Forkhead box C2 promoter variant c.-512C>T is associated with increased susceptibility to chronic venous diseases.

    Directory of Open Access Journals (Sweden)

    Sumi Surendran

    Full Text Available Chronic venous disease (CVD is one of the most prevalent yet underrated disorders worldwide. High heritability estimates of CVD indicate prominent genetic components in its etiology and pathology. Mutations in human forkhead box C2 (FoxC2 gene are strongly associated with valve failure in saphenous and deep veins of lower extremities. We explored the association of genetic variants of FoxC2 as well as FoxC2 mRNA and protein expression levels with CVD of lower limbs. We systematically sequenced the single coding exon, 5' and 3' flanking regions of FoxC2 gene in 754 study subjects which includes 382 patients with CVD and 372 healthy subjects. Four novel and three reported polymorphisms were identified in our cohort. Three variants in 5' flanking region and one in 3' flanking region of FoxC2 gene were significantly associated with CVD risk. FoxC2 mRNA in vein tissues from 22 patients was 4±1.42 fold increased compared to saphenous veins from 20 normal subjects (pT (rs34221221: C>T variant which is located in the FoxC2 putative promoter region was further analyzed. Functional analysis of c.-512C>T revealed increased mRNA and protein expression in patients with homozygous TT genotype compared to heterozygous CT and wild CC genotypes. Luciferase assay indicated higher transcriptional activity of mutant compared to wild genotype of this variant. These findings suggested that c.-512C>T variant of FoxC2 was strongly associated with susceptibility to CVD and also that this variant resulted in FoxC2 overexpression. To obtain a mechanistic insight into the role of upregulated FoxC2 in varicosities, we overexpressed FoxC2 in venous endothelial cells and observed elevated expression of arterial markers Dll4 and Hey2 and downregulation of venous marker COUP-TFII. Our study indicates altered FoxC2-Notch signaling in saphenous vein wall remodeling in patients with varicose veins.

  3. MRI features of myositis ossificans with X-ray and CT findings

    International Nuclear Information System (INIS)

    Gu Xiang; Bai Rongjie; Qu Hui; Cheng Xiaoguang; Li Yuang

    2009-01-01

    Objective: To investigate the MRI features of myositis ossificans, and to address the correlation with X-ray radiography and CT findings. Methods: X-ray films, CT and MRI of 36 documented cases of myositis ossificans were retrospectively analyzed, and the literatures were reviewed. Results: Of the 36 cases, 4 cases occurred in the elbow joint, 4 in the shoulder joint, 15 in the hip joint, 6 in the tibiofibula, 5 in the femur, 1 in the metatarsal bones, and 1 in the ilium, respectively. Irregular patchy or lamellar high density calcification or ossification could be seen in the soft tissue parenchym on X-ray films and CT scan. Cortical bone integrity was preserved in diaphysis. CT enhanced scan showed that the swollen parenchyma was not enhanced and there was no parenchyma mass. On the early and middle stages, MR T 1 WI and T 2 WI showed slice-shaped low signal in the peripheral parenchyma, but patchy high signal was found around the low signal on T 2 WI. STIR showed mixed high and low signals in the swollen parenchyma with unclear demarcation. The lesions showed low signal on MR T 1 WI and T 2 WI in the late stage, and there was no edema in peripheral parenehyma. MRI enhanced scan found that the swollen parenchyma showed no enhancement in all stages. Conclusions: The imaging features of myositis ossificans have some characteristics. Misdiagnosis could be avoided when the disease was evaluated with the course. (authors)

  4. Picture analysis in CT-HF and its CT photographs

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Kohirasawa, Hideo; Shinojima, Masayasu; Tokui, Mitsuru; Seo, Kunihiko.

    1980-01-01

    CT (computed tomography) apparatus is rarely used yet in the field of dentistry, though it seems useful. It is possibly because of the artefacts caused by the metallic parts attached to teeth, the large partial volume effect due to many bones and the problems of positioning and reproducibility. After considering the various requirements of the CT apparatuses in dental field, CT-HF (of T/R type) was chosen as such apparatus, and installed as the first in dentistry. In the CT-HF apparatus, the inner diameter of the gantry is up to 300 mm, and the position of a tomographic plane is only 40 mm away from the front of gantry. Mainly the usefulness of scanography in positioning and the usefulness of the CT apparatus in the picture analysis and processing in dental field are described. (J.P.N.)

  5. X-ray, CT and MRI findings of synovial tuberculosis in joints

    International Nuclear Information System (INIS)

    Yu Jinghong; Tao Meili; You Zhuangzhi; Yu Huazhi

    2006-01-01

    Objective: To analyze the X-ray, CT and MRI findings of synovial tuberculosis, and to evaluate the role of MRI in diagnosing synovial tuberculosis. Methods: Fourteen cases of synovial tuberculosis comfirmed by operation and pathology were retrospectively analyzed and summarized. All patients were examined by MRI and X-ray, and CT scans were performed in 3 cases. Results: X-ray showed joint swelling (8 cases), articular space narrowing (7 cases), marginal joint erosions (4 cases), and periarticular osteoporosis (9 cases). The joint swelling was detected on CT in all 3 cases, and bony erosion and speckled sequestra were seen in 2 cases. MRI in all of patients showed joint swelling and synovial proliferation in different drgees, demonstrated as heterogeneously low signal on T 1 WI and slight high signal (7 cases) and obvious high signal (6 cases) on T 2 WI, and diffuse synovial proliferation was demonstrated as massive and nodular signal in 8 cases. Joint effusion was present in 7 cases as low signal on T 1 WI and high signal on T 2 WI. Osseous erosion lesions were seen in 7 cases, and intra-articular cartilage thinned, partly or mostly disappeared in 11 cases. Periarticular bone marrow edema was found in 7 cases. Conclusion: MRI was superior to X-ray and CT in the diagnosis and differential diagnosis of synovial tuberculosis. (authors)

  6. Tensile fracture behaviors of T-ZnOw/polyamide 6 composites

    International Nuclear Information System (INIS)

    Shi Jing; Wang Yong; Liu Li; Bai Hongwei; Wu Jun; Jiang Chongxi; Zhou, Zuowan

    2009-01-01

    As a part of serial work about the application of tetra-needle-shaped zinc oxide whisker (T-ZnOw) in polymer composites, this work is focused on the crystallization and tensile fracture behaviors of T-ZnOw/polyamide 6 (T-ZnOw/PA6) composites. Our results show that the addition of T-ZnOw improves the composites tensile strength greatly. For virgin PA6, the stress-strain curve exhibits double-yielding phenomenon. Surface modified T-ZnOw reinforced PA6 composites exhibit higher yield stress and smaller strain-to-fracture compared with virgin PA6. The morphologies of tensile-fractured surfaces show that, addition of T-ZnOw changes the fracture mode from crazing-tearing/brittle fracture mode of virgin PA6 into fibrillation/brittle fracture mode of PA6 composites. Especially, the fracture process of T-ZnOw in composites during the tensile test has been characterized by scanning electronic microscope (SEM) and the corresponding reinforcement mechanism has been discussed.

  7. Synthesis and characterization of 6,6’-bis(2-hydroxyphenyl)-2,2’-bipyridine ligand and its interaction with ct-DNA

    International Nuclear Information System (INIS)

    Selamat, Norhidayah; Heng, Lee Yook; Hassan, Nurul Izzaty; Karim, Nurul Huda Abd

    2015-01-01

    The tetradentate ligand with four donor atoms OONN was synthesized. Bis(phenoxy)bipyridine ligand was prepared by Suzuki coupling reaction between 6,6’-dibromo-2,2’-bipyridyl and 2-hydroxyphenylboronic acid with presence of palladium (II) acetate. Bis(phenoxy)bipyridine ligand was also synthesized by demethylating of 6,6’-bis(2-methoxyphenyl)-2,2’-bipyridyl ligand through solvent free reaction using pyridine hydrocloride. The formation of both phenoxy and methoxy ligands was confirmed by 1 H, 2D cosy and 13 C NMR spectroscopy, ESI-MS spectrometry, FTIR spectroscopy. The purity of the ligand was confirmed by melting point. Binding studies of small molecules with DNA are useful to understand the reaction mechanism and to provide guidance for the application and design of new and more efficient drugs targeted to DNA. In this study, the binding interaction between the synthesized ligand with calf thymus-DNA (ct-DNA) has been investigated by UV/Vis DNA titration study. From the UV/Vis DNA study, it shows that bis(phenoxy)bipyridine ligand bind with ct-DNA via outside binding with binding contant K b = 1.19 × 10 3 ± 0.08 M −1

  8. CT, MRI, and FDG-PET/CT imaging findings of abdominopelvic desmoplastic small round cell tumors: Correlation with histopathologic findings

    International Nuclear Information System (INIS)

    Zhang Weidong; Li Chuanxing; Liu Qingyu; Hu Yingying; Cao Yun; Huang Jinhua

    2011-01-01

    Objective: To analyze computed tomography (CT), magnetic resonance imaging (MRI), and fluorodeoxyglucose-positron emission tomography (FDG-PET)/CT imaging features of abdominopelvic desmoplastic small round cell tumor (DSRCT) and to improve the diagnostic efficacy of these techniques for the detection of such tumor. Methods: We retrospectively analyzed 7 cases of abdominopelvic DSRCT confirmed by histopathologic analysis. Among the 7 patients, 5 patients had undergone CT scanning, 2 of which were also examined with FDG-PET/CT imaging, and 2 had undergone MRI. Unenhanced and contrast-enhanced examinations were performed in all patients, and 2 patients had also undergone dynamic CT contrast-enhanced examinations. Image characteristics, such as shape, size, number, edge, attenuation, and intensity of each lesion before and after contrast enhancement were analyzed and compared with the pathomorphology of the tumors. Results: Multiple large masses in the abdominopelvis were detected in 6 cases, and a large mass in the pelvis was detected in 1 case. Six cases showed largest mass in pelvis, and 1 case in mesentery. None of the masses had a definite organ origin. CT showed soft tissue masses with patchy foci of hypodense areas. MR T1-weighted images revealed lesions with mild hypointense areas and patchy hypointense areas in 2 cases and lesions with patchy hyperintense areas in 1 case. T2-weighted images showed lesions with mixed isointense and hyperintense areas in 1 case and lesions with mixed hypointense, isointense, and hyperintense areas in another. Contrast-enhanced CT and T1-weighted images showed mildly heterogeneous enhancement of the lesions. Other associated findings included peritoneal seeding (n = 3), peritoneal effusions (n = 3), hepatic metastasis (n = 2), bone metastasis (n = 1), and mesenteric and retroperitoneal lymphadenopathy (n = 4). FDG-PET/CT showed multiple nodular foci of increased metabolic activity in the abdominopelvic masses, in the hepatic and

  9. MO-F-CAMPUS-J-05: Toward MRI-Only Radiotherapy: Novel Tissue Segmentation and Pseudo-CT Generation Techniques Based On T1 MRI Sequences

    Energy Technology Data Exchange (ETDEWEB)

    Aouadi, S; McGarry, M; Hammoud, R; Torfeh, T; Perkins, G; Al-Hammadi, N [Hamad Medical Corporation, NCCCR, Doha (Qatar)

    2015-06-15

    Purpose: To develop and validate a 4 class tissue segmentation approach (air cavities, background, bone and soft-tissue) on T1 -weighted brain MRI and to create a pseudo-CT for MRI-only radiation therapy verification. Methods: Contrast-enhanced T1-weighted fast-spin-echo sequences (TR = 756ms, TE= 7.152ms), acquired on a 1.5T GE MRI-Simulator, are used.MRIs are firstly pre-processed to correct for non uniformity using the non parametric, non uniformity intensity normalization algorithm. Subsequently, a logarithmic inverse scaling log(1/image) is applied, prior to segmentation, to better differentiate bone and air from soft-tissues. Finally, the following method is enrolled to classify intensities into air cavities, background, bone and soft-tissue:Thresholded region growing with seed points in image corners is applied to get a mask of Air+Bone+Background. The background is, afterward, separated by the scan-line filling algorithm. The air mask is extracted by morphological opening followed by a post-processing based on knowledge about air regions geometry. The remaining rough bone pre-segmentation is refined by applying 3D geodesic active contours; bone segmentation evolves by the sum of internal forces from contour geometry and external force derived from image gradient magnitude.Pseudo-CT is obtained by assigning −1000HU to air and background voxels, performing linear mapping of soft-tissue MR intensities in [-400HU, 200HU] and inverse linear mapping of bone MR intensities in [200HU, 1000HU]. Results: Three brain patients having registered MRI and CT are used for validation. CT intensities classification into 4 classes is performed by thresholding. Dice and misclassification errors are quantified. Correct classifications for soft-tissue, bone, and air are respectively 89.67%, 77.8%, and 64.5%. Dice indices are acceptable for bone (0.74) and soft-tissue (0.91) but low for air regions (0.48). Pseudo-CT produces DRRs with acceptable clinical visual agreement to CT

  10. Association of the C-Reactive Protein Gene (CRP rs1205 C>T Polymorphism with Aortic Valve Calcification in Patients with Aortic Stenosis

    Directory of Open Access Journals (Sweden)

    Ewa Wypasek

    2015-10-01

    Full Text Available Elevation in C-reactive protein (CRP levels have been shown in patients with aortic valve stenosis (AS. Minor allele of the CRP gene (CRP rs1205 C>T polymorphism has been associated with lower plasma CRP concentrations in cohorts of healthy and atherosclerotic patients. Considering the existing similarities between atherosclerosis and AS, we examined the effect of CRP rs1205 C>T polymorphism on the AS severity. Three hundred consecutive Caucasian patients diagnosed with AS were genotyped for the rs1205 C>T polymorphism using the TaqMan assay. Severity of the AS was assessed using transthoracic echocardiography. The degree of calcification was analyzed semi-quantitatively. Carriers of the rs1205 T allele were characterized by elevated serum CRP levels (2.53 (1.51–3.96 vs. 1.68 (0.98–2.90 mg/L, p < 0.001 and a higher proportion of the severe aortic valve calcification (70.4% vs. 55.1%, p = 0.01 compared with major homozygotes. The effect of CRP rs1205 polymorphism on CRP levels is opposite in AS-affected than in unaffected subjects, suggesting existence of a disease-specific molecular regulatory mechanism. Furthermore, rs1205 variant allele predisposes to larger aortic valve calcification, potentially being a novel genetic risk marker of disease progression.

  11. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.; Ganzkoerper-Computertomographie. Spiral- und Multislice-CT

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-07-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  12. Radiotherapy and the importance of CT for the nasopharyngeal squammous cell carcinoma, 1

    International Nuclear Information System (INIS)

    Yamashita, Shoji; Dokiya, Takushi.

    1987-01-01

    Thirty-five patients with nasopharyngeal squamous cell carcinoma (NPC) were examined with computed tomography (CT) before definitive radiotherapy. CT clearly delincated the extent of the primary tumors. CT frequently showed subtle destruction of the paranasal sinuses and pterygoid plate, which was not usually detected by conventional X-ray examinations. T-staging was made according to the UICC TNM classification system (1978), depending on the clinical findings and the conventional X-ray examinations (non-CT T-stage). Then the non-CT T-stage of each patient was compared with T-stage diagnosed with CT findings alone (CT T-stage). CT upstaged non-CT T-stage in 14 of the 35 patients. Only one patient was downstaged by CT ; this patient had cranial nerve palsy but no detectable bone destruction as shown by CT. Since CT can reveal both bones and abnormal soft tissues well, it is a very useful diagnostic tool for the staging of the tumor assessment of treatment planning. Before radiotherapy, we should use CT to confirm that whether the tumor was located within the radiation field. CT is also useful to see the tumor regression after definitive radiotherapy. We conclude that CT is the single, most reliable imaging method for primary tumors of the NPC patients. (author)

  13. 18F-FDG PET/CT findings of autoimmune pancreatitis

    International Nuclear Information System (INIS)

    Chen Wen; Yang Zhenghan; Qu Wanying; Yao Zhiming; Liu Fugeng

    2013-01-01

    Objective: To investigate the image characteristics and clinical application of 18 F-FDG PET/CT in autoimmune pancreatitis (AIP). Methods: The PET/CT images from six male patients (age ranging from 51 to 78(average 69) years) with AIP from 2005 to 2012 were studied retrospectively. Of the six patients,two had follow-up PET/CT images after steroid therapy. The morphologic abnormality was visually analyzed and SUV was calculated. Scores were obtained according to the SUV of pancreas compared with that of the liver (3=SUV higher than liver, 2=SUV similar to liver, 1=SUV lower than liver). The difference between the regular and delayed SUV was compared by paired t test using SPSS 17.0. Results: All of the 6 patients showed diffuse FDG uptake in the entire pancreas with SUV max of 3.2-6.0(5.2± 1.1). Five patients had score 3 and one had score 2. Five patients had delayed scan, of which 4 had increased uptake (SUV max 5.3-7.2), but the SUV max was not significantly different compared to that before delay scan (4.8-6.0, t=-2.424, P>0.05). Five patients showed extrapancreatic uptake, especially in the salivary glands. After the steroid therapy, the enlarged pancreas reduced and the intense uptake of the pancreas disappeared. The extrapancreatic uptake showed coinstantaneous remission. Conclusions: Increasing FDG uptake at entire pancreas was observed in patients with AIP. 18 F-FDG PET/CT may be useful for detecting AIP and the associated extrapancreatic uptake,and monitoring the change after therapy, yet it needs further evaluation. (authors)

  14. CT quantification of central airway in tracheobronchomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Im, Won Hyeong; Jin, Gong Yong; Han, Young Min; Kim, Eun Young [Dept. of Radiology, Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2016-05-15

    To know which factors help to diagnose tracheobronchomalacia (TBM) using CT quantification of central airway. From April 2013 to July 2014, 19 patients (68.0 ± 15.0 years; 6 male, 13 female) were diagnosed as TBM on CT. As case-matching, 38 normal subjects (65.5 ± 21.5 years; 6 male, 13 female) were selected. All 57 subjects underwent CT with end-inspiration and end-expiration. Airway parameters of trachea and both main bronchus were assessed using software (VIDA diagnostic). Airway parameters of TBM patients and normal subjects were compared using the Student t-test. In expiration, both wall perimeter and wall thickness in TBM patients were significantly smaller than normal subjects (wall perimeter: trachea, 43.97 mm vs. 49.04 mm, p = 0.020; right main bronchus, 33.52 mm vs. 42.69 mm, p < 0.001; left main bronchus, 26.76 mm vs. 31.88 mm, p = 0.012; wall thickness: trachea, 1.89 mm vs. 2.22 mm, p = 0.017; right main bronchus, 1.64 mm vs. 1.83 mm, p = 0.021; left main bronchus, 1.61 mm vs. 1.75 mm, p = 0.016). Wall thinning and decreased perimeter of central airway of expiration by CT quantification would be a new diagnostic indicators in TBM.

  15. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  16. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  17. Methylenetetrahydrofolate reductase 677C>T and methionine synthase 2756A>G mutations: no impact on survival, cognitive functioning, or cognitive decline in nonagenarians

    DEFF Research Database (Denmark)

    Bathum, Lise; von Bornemann Hjelmborg, Jacob; Christiansen, Lene

    2007-01-01

    BACKGROUND: Several reports have shown an association between homocysteine, cognitive functioning, and survival among the oldest-old. Two common polymorphisms in the genes coding for methylenetetrahydrofolate reductase (MTHFR 677C>T) and methionine synthase (MTR 2756A>G) have an impact on plasma...... homocysteine level. METHODS: We examined the effect of the MTHFR 677C>T and MTR 2756A>G genotypes on baseline cognitive functioning, cognitive decline over 5 years measured in three assessments, and survival in a population-based cohort of 1581 nonagenarians. Cognitive functioning was assessed by using...

  18. Clinical studies on thyroid CT number in Graves' disease and destructive thyrotoxicosis

    International Nuclear Information System (INIS)

    Kamijo, Keiichi

    1994-01-01

    The purpose of the present study was to investigate CT Hounsfield unit (H.U.) of the thyroid in hyperthyroid and euthyroid Graves' disease and destructive thyrotoxicosis. The mean thyroid CT number in 95 controls was 122±18 H.U.(±SD) and did not change significatly with advancing age. The mean thyroid CT number (±SD) of 85±22 H.U. in 60 patients with hyperthyroid Graves' disease was significantly lower than either in normal controls or 116±22 H.U. in 11 patients with euthyroid Graves' disease. Comparison of thyroid hormones and TSH receptor Ab values of untreated patients with a normal and an abnormally low thyroid CT number showed that serum total and free T 3 were significantly higher in the latter group than the former group. With respect to the effect of methimazol (MMI) on the thyroid CT number, in the untreated 10 patients with a low thyroid CT number, the initial mean CT number was 65±11 H.U. and increased significantly to 76±14 H.U. after treatment with MMI. In contrast, in 6 patients with a normal thyroid CT number prior to therapy, the initial mean thyroid CT number was 102±11 H.U. and fell significantly to 84±16 H.U. after treatment with MMI. The thyroid CT number in destructive thyrotoxicosis is markedly decreased to less than 70 H.U. and the mean values of 57±7 H.U. in 6 patients with silent thyroiditis and of 61±5 H.U. in 7 with subacute thyroiditis differ significantly from Graves' disease. In conclusion, the thyroid CT number is significantly reduced in hyperthyroid Graves' disease, normal in euthyroid Graves' disease and markedly decreased in destructive thyrotoxicosis. The high T-3 value seemed to play an important role in the pathogenesis of a decline in the thyroid CT number in Graves' disease. An antithyroid drug therapy caused two different changes in the thyroid CT number, depending on whether the thyroid CT number prior to therapy was normal or low. (author)

  19. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K [Department of Radiation Oncology, NYU Langone Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  20. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    International Nuclear Information System (INIS)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K

    2016-01-01

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  1. A comparative study of N-glycolylneuraminic acid (Neu5Gc and cytotoxic T cell (CT carbohydrate expression in normal and dystrophin-deficient dog and human skeletal muscle.

    Directory of Open Access Journals (Sweden)

    Paul T Martin

    Full Text Available The expression of N-glycolylneuraminic acid (Neu5Gc and the cytotoxic T cell (CT carbohydrate can impact the severity of muscular dystrophy arising from the loss of dystrophin in mdx mice. Here, we describe the expression of these two glycans in skeletal muscles of dogs and humans with or without dystrophin-deficiency. Neu5Gc expression was highly reduced (>95% in muscle from normal golden retriever crosses (GR, n = 3 and from golden retriever with muscular dystrophy (GRMD, n = 5 dogs at multiple ages (3, 6 and 13 months when compared to mouse muscle, however, overall sialic acid expression in GR and GRMD muscles remained high at all ages. Neu5Gc was expressed on only a minority of GRMD satellite cells, CD8⁺ T lymphocytes and macrophages. Human muscle from normal (no evident disease, n = 3, Becker (BMD, n = 3 and Duchenne (DMD, n = 3 muscular dystrophy individuals had absent to very low Neu5Gc staining, but some punctate intracellular muscle staining was present in BMD and DMD muscles. The CT carbohydrate was localized to the neuromuscular junction in GR muscle, while GRMD muscles had increased expression on a subset of myofibers and macrophages. In humans, the CT carbohydrate was ectopically expressed on the sarcolemmal membrane of some BMD muscles, but not normal human or DMD muscles. These data are consistent with the notion that altered Neu5Gc and CT carbohydrate expression may modify disease severity resulting from dystrophin deficiency in dogs and humans.

  2. Clinical application of CT and CT-guided percutaneous transthoracic needle biopsy in patients with indeterminate pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Luciana Vargas; Souza Júnior, Arthur Soares, E-mail: fabianonatividade@terra.com.br [Rio Preto-Ultra-X Radiological Diagnosis Institute, São José do Rio Preto, SP (Brazil)

    2014-07-15

    Objective: To investigate the clinical application of CT and CT-guided percutaneous transthoracic needle biopsy (CT-PTNB) in patients with indeterminate pulmonary nodules (IPNs). Methods: We retrospectively studied 113 patients with PNs undergoing CT and CT-PTNB. Variables such as gender, age at diagnosis, smoking status, CT findings, and CT-PTNB techniques were analyzed. Data analysis was performed with the Student's t-test for independent samples the chi-square test, and normal approximation test for comparison of two proportions. Results: Of the 113 patients studied, 68 (60.2%) were male and 78 (69%) were smokers. The diameter of malignant lesions ranged from 2.6 cm to 10.0 cm. Most of the IPNs (85%) were located in the peripheral region. The biopsied IPNs were found to be malignant in 88 patients (77.8%) and benign in 25 (22.2%). Adenocarcinoma was the most common malignant tumor, affecting older patients. The IPN diameter was significantly greater in patients with malignant PNs than in those with benign IPNs (p < 0.001). Having regular contour correlated significantly with an IPN being benign (p = 0.022), whereas spiculated IPNs and bosselated IPNs were more often malignant (in 50.7% and 28.7%, respectively). Homogeneous attenuation and necrosis were more common in patients with malignant lesions (51.9% and 26.9%, respectively). Conclusions: In our sample, CT and CT-PTNB were useful in distinguishing between malignant and benign IPNs. Advanced age and smoking were significantly associated with malignancy. Certain CT findings related to IPNs (larger diameter, spiculated borders, homogeneous attenuation, and necrosis) were associated with malignancy. (author)

  3. Measurement of skeletal muscle area: Comparison of CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sinelnikov, Andrey, E-mail: sinelnikovas@upmc.edu [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Qu, Chuanxing [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Fetzer, David T. [Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Pelletier, Jean-Sébastien [Department of Surgery, Jewish General Hospital, McGill University, Montreal, Quebec (Canada); Dunn, Michael A. [Department of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Tsung, Allan [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Furlan, Alessandro [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2016-10-15

    Objective: To investigate the intra- and inter-observer agreement and correlation between CT and MR measurements of skeletal muscle area (SMA) in the abdomen. Methods: CT and MR images from twelve patients were analyzed by two blinded observers using segmentation software (MITK-3M3, Mint Medical and Slice-O-Matic, Tomovision) to quantify SMA. MR images included T1w “in-phase”, T1w “out-of-phase”, and T2w sequences. Inter- and intra-observer agreement was assessed using the intraclass correlation coefficient (ICC). Pearson correlation coefficient (r) was used to correlate measurements obtained on MR with CT. CT and MR measurements were compared with Bland-Altman plots. Results: Intra- and inter-observer agreement for SMA was high for CT and MR. For MR, the measurements on T2w images showed the highest inter-observer agreement (ICC = 0.96). CT SMA correlated closely with MR, with T2w images showing the highest correlation (r = 0.98; P < 0.01). Bland-Altman plots showed a 1.7%–3.9% bias between CT and MR measurements, lowest for T2w images. Conclusions: MR SMA measurements are reproducible and correlate closely with CT. The T2w sequence is recommended to quantify SMA on MR images.

  4. CT diagnosis of the primary lung cancer and usefulness of biopsy under CT

    International Nuclear Information System (INIS)

    Fujisawa, Hidefumi; Kushihashi, Tamio

    2011-01-01

    CT especially plays an important role in imaging diagnosis of lung cancer (LC) which gives quite multiple CT findings and this paper describes details to be noted for CT findings of individual lung lesion and cancer according to 5 classes below, together with usefulness of CT-guided biopsy and positron emission tomography (PET) usage. Explained are as follows: Important points in histopathology and CT findings from adenomatous hyperplasia (AH) to atypical AH (pre-invasive lesion); Differential CT diagnosis of benignity or malignancy of pulmonary nodes and tumors; Typical CT findings of LC of peripheral type of invasive or exclusive proliferative type, and pulmonary hillar type; Atypical CT findings of LC/having atypical inner structure such as presenting atypical calcification and atypical cavity/having atypical morphology such as presenting pneumonia-like finding, exhibiting regular or linear edge, and existing at atypical region like extrapleural lumen /having atypical progression rate such as showing rapid or slow doubling time of the volume and shrinking tentatively during the progress/of juvenile LC/and generated from background lung diseases such as interstitial pneumonia, tuberculosis, pneumoconiosis like asbestosis, pneumosilicosis, and pulmonary emphysema and bulla; and Regional ground glass opacity. As well, authors mention about the usefulness of CT-guided needle biopsy of the pulmonary lesion which enables to take the nodal specimen as small as <10 mm. Most frequent complication of the biopsy is pneumothorax (10-50%). How to use PET for LC examination is also commented with its usability and limitation. (T.T.)

  5. The reaction of unirradiated and irradiated nuclear graphites with water vapor in helium

    International Nuclear Information System (INIS)

    Imai, Hisashi; Nomura, Shinzo; Kurosawa, Takeshi; Fujii, Kimio; Sasaki, Yasuichi

    1980-10-01

    Nuclear graphites more than 10 brands were oxidized with water vapor in helium and then some selected graphites were irradiated with fast neutron in the Japan Materials Testing Reactor to clarify the effect of radiation damage of graphite on their reaction behaviors. The reaction was carried out under a well defined condition in the temperature range 800 -- 1000 0 C at concentrations of water vapor 0.38 -- 1.30 volume percent in helium flow of total pressure of 1 atm. The chemical reactivity of graphite irradiated at 1000 +- 50 0 C increased linearly with neutron fluence until irradiation of 3.2 x 10 21 n/cm 2 . The activation energy for the reaction was found to decrease with neutron fluence for almost all the graphites, except for a few ones. The order of reaction increased from 0.5 for the unirradiated graphite to 1.0 for the graphite irradiated up to 6.0 x 10 20 n/cm 2 . Experiment was also performed to study a superposed effect between the influence of radiation damage of graphite and the catalytic action of barium on the reaction rate, as well as the effect of catalyser of barium. It was shown that these effects were not superposed upon each other, although barium had a strong catalytic action on the reaction. (author)

  6. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma.

    Science.gov (United States)

    Qi, Zhihua; Gates, Erica L; O'Brien, Maureen M; Trout, Andrew T

    2018-02-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (PCT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations.

  7. Damage and failure of unirradiated and irradiated fuel rods tested under film boiling conditions

    International Nuclear Information System (INIS)

    Mehner, A.S.; Hobbins, R.R.; Seiffert, S.L.; MacDonald, P.E.; McCardell, R.K.

    1979-01-01

    Power-cooling-mismatch experiments are being conducted as part of the Thermal Fuels Behavior Program in the Power Burst Facility at the Idaho National Engineering Laboratory to evaluate the behavior of unirradiated and previously irradiated light water reactor fuel rods tested under stable film boiling conditions. The observed damage that occurs to the fuel rod cladding and the fuel as a result of film boiling operation is reported. Analyses performed as a part of the study on the effects of operating failed fuel rods in film boiling, and rod failure mechanisms due to cladding embrittlement and cladding melting upon being contacted by molten fuel are summarized

  8. Association of FXII 5’UTR 46C>T polymorphism with FXII activity and risk of thrombotic disease

    Directory of Open Access Journals (Sweden)

    Parisa Rasighaemi

    2010-03-01

    Full Text Available Objective: Thrombotic diseases are caused by genetic and environmental factors. There are a number of well-characterized genetic defects that lead to increased risk of thrombosis. Results from previous studies have indicated that FXII is involved in the pathogenesis of thrombophilic diseases. However, the results in this regard are highly controversial. One of the most important determinants of Plasma FXII level is 46CgT polymorphism in the FXII gene. In the present study, the risk of thrombophilic diseases related to this polymorphism was investigated in a case-control study. Material and Methods: One hundred and sixty subjects were studied: 120 patients diagnosed with thrombophilia (96 venous thromboembolism, 24 arterial thrombosis, and 40 age-gender-matched controls. For each subject, FXII activity level was measured by a one-step clotting assay with FXII-deficient plasma, and 46CγT polymorphism was genotyped using a restriction fragment length polymorphism (RFLP method. Results: In this study, the previous observation that individuals with different genotypes for the 46 CγT polymorphism show significant differences in FXII activity levels was confirmed. Most importantly, FXII activity ≤68% was associated with an increased risk of venous thrombosis with an adjusted odds ratio (OR of 4.7 (95% confidence interval [CI]: 1.03-21.1, p=0.04. However, it was not a risk factor for arterial thrombosis with adjusted OR of 5 (95% CI: 0.91-27.1, p=0.09. In CT and TT genotype, the adjusted ORs were 2 (95% CI: 0.9-4.4, p=0.11 and 2.3 (95% CI: 0.45-11, p=0.48, respectively, for patients with venous thrombosis compared with the controls. Similarly, the adjusted ORs in arterial thrombosis were 1.2 (95% CI: 0.4-3.6, p=0.76 for CT and 1.8 (95% CI: 0.2-14.9, p=0.59 for TT genotype. Thus, we did not find any association of the mutated T allele in the heterozygous or homozygous state with an increased risk of venous or arterial thrombosis. Conclusion: Lower

  9. CT scout films: Don't forget to look.

    Energy Technology Data Exchange (ETDEWEB)

    Emamian, Seyed A.; Dubovsky, Elizabeth C.; Vezina, L. Gilbert; Bulas, Dorothy I. [Department of Diagnostic Imaging and Radiology, Children' s National Medical Center, George Washington University, 111 Michigan Avenue NW, DC 20010, Washington (United States); Carter, William [Department of Radiology, Bethesda Naval Medical Center, Rockville, MD (United States)

    2003-08-01

    A lateral scout view of the head is always obtained when performing head computed tomography (CT). It is common knowledge that viewing the lateral scout view may provide additional information. For a variety of reasons, however, a careful review may not be performed routinely. To illustrate the value of the lateral scout view, we present a series of representative cases. Six patients with clinically relevant findings on the scout view. Most of the ancillary findings were in the upper cervical spine/neck, which is typically included on the lateral scout view. Careful evaluation of the scout view of the head CT, including the skull and neck, may yield valuable information, which may not be visualized on the axial CT images. (orig.)

  10. Synthesis and characterization of 6,6’-bis(2-hydroxyphenyl)-2,2’-bipyridine ligand and its interaction with ct-DNA

    Energy Technology Data Exchange (ETDEWEB)

    Selamat, Norhidayah; Heng, Lee Yook; Hassan, Nurul Izzaty; Karim, Nurul Huda Abd [School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43650 Bangi, Selangor (Malaysia)

    2015-09-25

    The tetradentate ligand with four donor atoms OONN was synthesized. Bis(phenoxy)bipyridine ligand was prepared by Suzuki coupling reaction between 6,6’-dibromo-2,2’-bipyridyl and 2-hydroxyphenylboronic acid with presence of palladium (II) acetate. Bis(phenoxy)bipyridine ligand was also synthesized by demethylating of 6,6’-bis(2-methoxyphenyl)-2,2’-bipyridyl ligand through solvent free reaction using pyridine hydrocloride. The formation of both phenoxy and methoxy ligands was confirmed by {sup 1}H, 2D cosy and {sup 13}C NMR spectroscopy, ESI-MS spectrometry, FTIR spectroscopy. The purity of the ligand was confirmed by melting point. Binding studies of small molecules with DNA are useful to understand the reaction mechanism and to provide guidance for the application and design of new and more efficient drugs targeted to DNA. In this study, the binding interaction between the synthesized ligand with calf thymus-DNA (ct-DNA) has been investigated by UV/Vis DNA titration study. From the UV/Vis DNA study, it shows that bis(phenoxy)bipyridine ligand bind with ct-DNA via outside binding with binding contant K{sub b} = 1.19 × 10{sup 3} ± 0.08 M{sup −1}.

  11. Cladding axial elongation models for FRAP-T6

    International Nuclear Information System (INIS)

    Shah, V.N.; Carlson, E.R.; Berna, G.A.

    1983-01-01

    This paper presents a description of the cladding axial elongation models developed at the Idaho National Engineering Laboratory (INEL) for use by the FRAP-T6 computer code in analyzing the response of fuel rods during reactor transients in light water reactors (LWR). The FRAP-T6 code contains models (FRACAS-II subcode) that analyze the structural response of a fuel rod including pellet-cladding-mechanical-interaction (PCMI). Recently, four models were incorporated into FRACAS-II to calculate cladding axial deformation: (a) axial PCMI, (b) trapped fuel stack, (c) fuel relocation, and (d) effective fuel thermal expansion. Comparisons of cladding axial elongation measurements from two experiments with the corresponding FRAP-T6 calculations are presented

  12. Stereotactic imaging for radiotherapy: accuracy of CT, MRI, PET and SPECT

    International Nuclear Information System (INIS)

    Karger, Christian P; Hipp, Peter; Henze, Marcus; Echner, Gernot; Hoess, Angelika; Schad, Lothar; Hartmann, Guenther H

    2003-01-01

    CT, MRI, PET and SPECT provide complementary information for treatment planning in stereotactic radiotherapy. Stereotactic correlation of these images requires commissioning tests to confirm the localization accuracy of each modality. A phantom was developed to measure the accuracy of stereotactic localization for CT, MRI, PET and SPECT in the head and neck region. To this end, the stereotactically measured coordinates of structures within the phantom were compared with their mechanically defined coordinates. For MRI, PET and SPECT, measurements were performed using two different devices. For MRI, T1- and T2-weighted imaging sequences were applied. For each measurement, the mean radial deviation in space between the stereotactically measured and mechanically defined position of target points was determined. For CT, the mean radial deviation was 0.4 ± 0.2 mm. For MRI, the mean deviations ranged between 0.7 ± 0.2 mm and 1.4 ± 0.5 mm, depending on the MRI device and the imaging sequence. For PET, mean deviations of 1.1 ± 0.5 mm and 2.4 ± 0.3 mm were obtained. The mean deviations for SPECT were 1.6 ± 0.5 mm and 2.0 ± 0.6 mm. The phantom is well suited to determine the accuracy of stereotactic localization with CT, MRI, PET and SPECT in the head and neck region. The obtained accuracy is well below the physical resolution for CT, PET and SPECT, and of comparable magnitude for MRI. Since the localization accuracy may be device dependent, results obtained at one device cannot be generalized to others

  13. Observation of femoral and tibial insertion of the posterior cruciate ligament by using conventional CT and transparent 3D-CT

    International Nuclear Information System (INIS)

    Inoue, Masayuki; Tsukuda, Koichiro; Yasojima, Nobutoshi; Oota, Masahiro; Kasahara, Yasuhiko

    2011-01-01

    Presented are image data acquisitioned by the volume rendering (VR)-3D-CT and authors' transparent (T)-3D-CT to depict the bone contour, of medial intercondylar ridge (MIR) and posterior intercodylar fossa (PIF) at femoral and tibial insertion, respectively, of the posterior cruciate ligament (PCL) as those data are helpful for planning the reconstruction surgery of PCL and for confirming the femoral PCL insertion by using the C-arm during operation. Helical scanning is conducted with GE MD-CT (64DAS) to reconstruct VR-3D-CT image with the workstation ZIO's ZIO900M Quadra and T-3D-CT image, by reducing the opacity by pixel exclusion of the intraosseous lumen. MIR is observed in all 70 normal knees tested in VR-3D-CT and the bifurcate ridge, in 15 knees among them. In T-3D-CT image, distance data of the origin of MIR from Blumensaat's line and the angle of MIR and bone axis are calculated and presented. In VR-3D-CT and T-3D-CT images of PIF from 20 knees, actual measures of PIF slope angle (degree), PIF area ratio to joint surface (JS) (%), distance from JS to centers of anterolateral (AL) and posterolateral (PM) slopes (mm), and from medial and lateral JS to PIF posterior border (mm), and distance ratios of PM and AL to medial and lateral tibia, respectively, (%) are calculated and presented. Findings are: MIR originates at 45% distal point of Blumensaat's line; the articular line crosses with PIF at its center in T-3D-CT sagittal plane; centers of tibial AL and PM exist at the middle of frontal plane, and at 1.00 and 5.5 mm, respectively, distal points of JS of sagittal plane. The PIF data are rather comparable to those obtained in cadavers reported in 3 literatures and the present procedure is concluded to be valid. (author)

  14. Comparative study of radiography, CT and MRI in the identification of hip involvement in patients with ankylosing spondylitis

    International Nuclear Information System (INIS)

    Huang Zhenguo; Zhang Xuezhe; Hu Libin; Wang Guochun; Zhou Huiqiong; Lu Xin; Wang Wu

    2012-01-01

    Objective: To study the imaging findings of hip involvement and to compare the sensitivity of radiography, CT, and MRI in the identification of hip involvement in patients with ankylosing spondylitis (AS). Methods: Anteroposterior radiography of the pelvis and MRI of hip were performed in 55 patients with AS. CT scan of hip was performed in 29 of 55 patients. T 1 -weighted, T 2 -weighted, short tau inversion recovery (STIR) and three dimensional balanced turbo field echo with water selective excitation (3D-BTFE-WATS) coronal sequences of hips were obtained in all patients, of which fat-saturated contrast-enhanced T 1 -weighted sequence was performed in 24 patients. The imaging data of 55 patients were analyzed. The chi-square test was used to analyze the sensitivity in the identification of hip involvement among radiography, CT, and MRI. Results: Among 110 hips in all 55 patients, abnormal changes were detected in 13 hips by radiography, 85 hips by MRI. The findings of radiography included bone erosions in 13 hips, joint space narrowing in 4 hips,syndesmophytes in 5 hips. MRI revealed bone erosive destruction in 31 hips, joint space narrowing in 4 hips, joint effusion in 80 hips, subchondral bone marrow edema in 32 hips, fat accumulation of bone marrow in 28 hips, enthesitis in 21 hips. Bilateral synovial enhancement was showed in 19 of 24 patients who underwent fat-saturated contrast-enhanced T 1 -weighted sequence. Of the 58 hip joints in 29 patients who underwent CT examination, not only did CT show all bone erosions detected by radiography and MRI, but CT revealed bone erosive destruction that were not identified by radiography in 10 hips and by MRI in 1 hip as well. Abnormal changes were detected in 10.3% (6/58)by radiography, 27.6% (16/58) by CT, and 77.6% (45/58) by MRI. The sensitivity of MRI in the identification of hip involvement is higher than that of radiography and CT (χ 2 =53.22 and 29.08, P<0.05). In addition to chronic bone structural changes, MRI

  15. Effects of the lactase 13910 C/T and calcium-sensor receptor A986S G/T gene polymorphisms on the incidence and recurrence of colorectal cancer in Hungarian population

    International Nuclear Information System (INIS)

    Bácsi, Krisztián; Speer, Gábor; Hitre, Erika; Kósa, János P; Horváth, Henrik; Lazáry, Áron; Lakatos, Péter L; Balla, Bernadett; Budai, Barna; Lakatos, Péter

    2008-01-01

    Epidemiological studies suggested the chemopreventive role of higher calcium intake in colorectal carcinogenesis. We examined genetic polymorphisms that might influence calcium metabolism: lactase (LCT) gene 13910 C/T polymorphism causing lactose intolerance and calcium-sensing receptor (CaSR) gene A986S polymorphism as a responsible factor for the altered cellular calcium sensation. 538 Hungarian subjects were studied: 278 patients with colorectal cancer and 260 healthy controls. Median follow-up was 17 months. After genotyping, the relationship between LCT 13910 C/T and CaSR A986S polymorphisms as well as tumor incidence/progression was investigated. in patient with colorectal cancer, a significantly higher LCT CC frequency was associated with increased distant disease recurrence (OR = 4.04; 95% CI = 1.71–9.58; p = 0.006). The disease free survival calculated from distant recurrence was reduced for those with LCT CC genotype (log rank test p = 0.008). In case of CaSR A986S polymorphism, the homozygous SS genotype was more frequent in patients than in controls (OR = 4.01; 95% CI = 1.33–12.07; p = 0.014). The number of LCT C and CaSR S risk alleles were correlated with tumor incidence (p = 0.035). The CCSS genotype combination was found only in patients with CRC (p = 0.033). LCT 13910 C/T and CaSR A986S polymorphisms may have an impact on the progression and/or incidence of CRC

  16. Diagnostic accuracy of 3-T magnetic resonance imaging with 3D T1 VIBE versus computer tomography in pars stress fracture of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Ang, E.C.; Robertson, A.F.; Malara, F.A.; O' Shea, T.; Roebert, J.K.; Rotstein, A.H. [Victoria House Medical Imaging, Prahran, Victoria (Australia); Schneider, M.E. [Monash University, Monash Biomedicine Discovery Institute, Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, Clayton, Victoria (Australia)

    2016-11-15

    To compare the diagnostic accuracy of 3-T magnetic resonance imaging (MRI) with thin-slice 3D T1 VIBE sequence to 128-slice computer tomography (CT) in pars stress fractures of the lumbar spine. 3-T MRI and CT of 24 patients involving 70 pars interarticularis were retrospectively reviewed by four blinded radiologists. The fracture morphology (complete, incomplete, or normal) was assessed on MRI and CT at different time points. Pars interarticularis bone marrow edema (present or absent) was also evaluated on MRI. In total, 14 complete fractures, 31 incomplete fractures and 25 normal pars were detected by CT. Bone marrow edema was seen in seven of the complete and 25 of the incomplete fractures. The overall sensitivity, specificity and accuracy of MRI in detecting fractures (complete and incomplete) were 97.7, 92.3, and 95.7 %, respectively. MRI was 100 % accurate in detecting complete fractures. For incomplete fractures, the sensitivity, specificity, and accuracy of MRI were 96.7, 92.0, and 94.6 %, respectively. 3-T MRI with thin-slice 3D T1 VIBE is 100 % accurate in diagnosing complete pars fractures and has excellent diagnostic ability in the detection and characterization of incomplete pars stress fractures compared to CT. MRI has the added advantages of detecting bone marrow edema and does not employ ionizing radiation. (orig.)

  17. Diagnostic accuracy of 3-T magnetic resonance imaging with 3D T1 VIBE versus computer tomography in pars stress fracture of the lumbar spine

    International Nuclear Information System (INIS)

    Ang, E.C.; Robertson, A.F.; Malara, F.A.; O'Shea, T.; Roebert, J.K.; Rotstein, A.H.; Schneider, M.E.

    2016-01-01

    To compare the diagnostic accuracy of 3-T magnetic resonance imaging (MRI) with thin-slice 3D T1 VIBE sequence to 128-slice computer tomography (CT) in pars stress fractures of the lumbar spine. 3-T MRI and CT of 24 patients involving 70 pars interarticularis were retrospectively reviewed by four blinded radiologists. The fracture morphology (complete, incomplete, or normal) was assessed on MRI and CT at different time points. Pars interarticularis bone marrow edema (present or absent) was also evaluated on MRI. In total, 14 complete fractures, 31 incomplete fractures and 25 normal pars were detected by CT. Bone marrow edema was seen in seven of the complete and 25 of the incomplete fractures. The overall sensitivity, specificity and accuracy of MRI in detecting fractures (complete and incomplete) were 97.7, 92.3, and 95.7 %, respectively. MRI was 100 % accurate in detecting complete fractures. For incomplete fractures, the sensitivity, specificity, and accuracy of MRI were 96.7, 92.0, and 94.6 %, respectively. 3-T MRI with thin-slice 3D T1 VIBE is 100 % accurate in diagnosing complete pars fractures and has excellent diagnostic ability in the detection and characterization of incomplete pars stress fractures compared to CT. MRI has the added advantages of detecting bone marrow edema and does not employ ionizing radiation. (orig.)

  18. First CT findings and improvement in GOS and GOSE scores 6 and 12 months after severe traumatic brain injury.

    Science.gov (United States)

    Corral, Luisa; Herrero, José Ignacio; Monfort, José Luis; Ventura, José Luis; Javierre, Casimiro F; Juncadella, Montserrat; García-Huete, Lucía; Bartolomé, Carlos; Gabarrós, Andreu

    2009-05-01

    To analyse the association between individual initial computerized tomography (CT) scan characteristics and Glasgow Outcome Scale (GOS) and Extended Glasgow Outcome Scale (GOSE) improvement between 6 months and 1 year. Two hundred and twenty-four adult patients with severe traumatic brain injury and Glasgow Coma Scale (GCS) score of 8 or less who were admitted to an intensive care unit were studied. GOS and GOSE scores were obtained 6 and 12 months after injury in 203 subjects. Patients were predominantly male (84%) and median age was 35 years. Traumatic Coma Data Bank (TCDB) CT classification was associated with GOS/GOSE improvement between 6 months and 1 year, with diffuse injury type I, type II and evacuated mass improving more than diffuse injury type III, type IV and non-evacuated mass; for GOS 43/155 (28%) vs 3/48 (6%) (chi(2) = 9.66, p GOSE 71/155 (46%) vs 7/48 (15%) (chi(2) = 15.1, p GOSE improvement, with the exception of subarachnoid haemorrhage, which showed a negative association with GOSE improvement (chi(2) = 4.08, p GOSE improvement from 6-12 months, but individual CT abnormalities were not associated.

  19. Structure and mechanism of a bacterial t6A biosynthesis system

    OpenAIRE

    Luthra, Amit; Swinehart, William; Bayooz, Susan; Phan, Phuc; Stec, Boguslaw; Iwata-Reuyl, Dirk; Swairjo, Manal A

    2018-01-01

    Abstract The universal N(6)-threonylcarbamoyladenosine (t6A) modification at position 37 of ANN-decoding tRNAs is central to translational fidelity. In bacteria, t6A biosynthesis is catalyzed by the proteins TsaB, TsaC/TsaC2, TsaD and TsaE. Despite intense research, the molecular mechanisms underlying t6A biosynthesis are poorly understood. Here, we report biochemical and biophysical studies of the t6A biosynthesis system from Thermotoga maritima. Small angle X-ray scattering analysis reveals...

  20. Lower rectal cancer. Preoperative staging with CT air enema technique

    International Nuclear Information System (INIS)

    Kanazawa, Amane; Fujii, Shouichi; Iwata, Seiichirou

    2009-01-01

    Preoperative assessment of rectal cancer wall invasion is an important indication of the need for lateral side wall dissection. The purpose of this study was to determine the accuracy rates and clinical usefulness of air-enema CT in preoperative staging of lower rectal cancer. A total of 88 patients diagnosed with lower rectal cancer were examined with an air-enema CT preoperatively and had surgical resection performed. One group was T1-T2 while the other was T3-T4. Forty-two patients were T1-T2, and 46 patients were T3-T4. In univariate and multivariate analysis, irregularities of the rectal wall and spiculated appearance of the rectal wall were significant predictive factors in T3-T4. In patients with air-enema CT findings of rectal wall irregularities and speculated appearance, the accuracy rate for detecting T3-T4 was 85.2-86.45 percent. These results show that air-enema CT is useful for determining the preoperative staging of lower rectal cancer and indication of the need for lateral side wall dissection. (author)

  1. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma

    International Nuclear Information System (INIS)

    Qi, Zhihua; Gates, Erica L.; Trout, Andrew T.; O'Brien, Maureen M.

    2018-01-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations. (orig.)

  2. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Zhihua; Gates, Erica L.; Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); O' Brien, Maureen M. [Cincinnati Children' s Hospital Medical Center, Division of Oncology, Cancer and Blood Disease Institute, Cincinnati, OH (United States)

    2018-02-15

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations. (orig.)

  3. CT volumetry for gastric carcinoma: association with TNM stage

    Energy Technology Data Exchange (ETDEWEB)

    Hallinan, James T.P.D.; Peter, Luke; Makmur, Andrew [National University Health System (NUHS), Diagnostic Radiology, Singapore (Singapore); Venkatesh, Sudhakar K. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Yong, Wei Peng [NUHS, Hematology and Oncology, Singapore (Singapore); So, Jimmy B.Y. [NUHS, Surgery, Singapore (Singapore)

    2014-12-15

    We evaluated the feasibility of performing CT volumetry of gastric carcinoma (GC) and its correlation with TNM stage. This institutional review board-approved retrospective study was performed on 153 patients who underwent a staging CT study for histologically confirmed GC. CT volumetry was performed by drawing regions of interest including abnormal thickening of the stomach wall. Reproducibility of tumour volume (Tvol) between two readers was assessed. Correlation between Tvol and TNM/peritoneal staging derived from histology/surgical findings was evaluated using ROC analysis and compared with CT evaluation of TNM/peritoneal staging. Tvol was successfully performed in all patients. Reproducibility among readers was excellent (r = 0.97; P = 0.0001). The median Tvol of GC showed an incremental trend with T-stage (T1 = 27 ml; T2 = 32 ml; T3 = 53 ml and T4 = 121 ml, P < 0.01). Tvol predicted with good accuracy T-stage (≥T2:0.95; ≥T3:0.89 and T4:0.83, P = 0.0001), M-stage (0.87, P = 0.0001), peritoneal metastases (0.87, P = 0.0001) and final stage (≥stage 2:0.89; ≥stage 3:0.86 and stage 4:0.87, P = 0.0001), with moderate accuracy for N-stage (≥N1:0.75; ≥N2:0.74 and N3:0.75, P = 0.0001). Tvol was significantly (P < 0.05) more accurate than standard CT staging for prediction of T-stage, N3-stage, M-stage and peritoneal metastases. CT volumetry may provide useful adjunct information for preoperative staging of GC. (orig.)

  4. CT volumetry for gastric carcinoma: association with TNM stage

    International Nuclear Information System (INIS)

    Hallinan, James T.P.D.; Peter, Luke; Makmur, Andrew; Venkatesh, Sudhakar K.; Yong, Wei Peng; So, Jimmy B.Y.

    2014-01-01

    We evaluated the feasibility of performing CT volumetry of gastric carcinoma (GC) and its correlation with TNM stage. This institutional review board-approved retrospective study was performed on 153 patients who underwent a staging CT study for histologically confirmed GC. CT volumetry was performed by drawing regions of interest including abnormal thickening of the stomach wall. Reproducibility of tumour volume (Tvol) between two readers was assessed. Correlation between Tvol and TNM/peritoneal staging derived from histology/surgical findings was evaluated using ROC analysis and compared with CT evaluation of TNM/peritoneal staging. Tvol was successfully performed in all patients. Reproducibility among readers was excellent (r = 0.97; P = 0.0001). The median Tvol of GC showed an incremental trend with T-stage (T1 = 27 ml; T2 = 32 ml; T3 = 53 ml and T4 = 121 ml, P < 0.01). Tvol predicted with good accuracy T-stage (≥T2:0.95; ≥T3:0.89 and T4:0.83, P = 0.0001), M-stage (0.87, P = 0.0001), peritoneal metastases (0.87, P = 0.0001) and final stage (≥stage 2:0.89; ≥stage 3:0.86 and stage 4:0.87, P = 0.0001), with moderate accuracy for N-stage (≥N1:0.75; ≥N2:0.74 and N3:0.75, P = 0.0001). Tvol was significantly (P < 0.05) more accurate than standard CT staging for prediction of T-stage, N3-stage, M-stage and peritoneal metastases. CT volumetry may provide useful adjunct information for preoperative staging of GC. (orig.)

  5. Plasminogen activator inhibitor-1 4G/5G and the MTHFR 677C/T polymorphisms and susceptibility to polycystic ovary syndrome: a meta-analysis.

    Science.gov (United States)

    Lee, Young Ho; Song, Gwan Gyu

    2014-04-01

    The aim of this study was to explore whether the plasminogen activator inhibitor-1 (PAI-1) 4G/5G and the methylenetetrahydrofolate reductase (MTHFR) 677C/T polymorphisms are associated with susceptibility to polycystic ovary syndrome (PCOS). Meta-analyses were conducted to determine the association between the PAI-1 4G/5G and MTHFR 677C/T polymorphisms and PCOS using: (1) allele contrast (2) homozygote contrast, (3) recessive, and (4) dominant models. For meta-analysis, nine studies of the PAI-1 4G/5G polymorphism with 2384 subjects (PCOS, 1615; controls, 769) and eight studies of the MTHFR 677C/T polymorphism with 1270 study subjects were included. Meta-analysis of all study subjects showed no association between PCOS and the PAI-1 4G allele (OR=0.949, 95% CI=0.671-1.343, p=0.767). Stratification by ethnicity, however, indicated a significant association between the PAI-1 4G allele and PCOS in Turkish and Asian populations (OR=0.776, 95% CI=0.602-0.999, p=0.049; OR=1.749, 95% CI=1.297-2.359, p=2.5×10(-5) respectively). In addition, meta-analysis indicated an association between PCOS and the PAI-1 4G4G+4G5G genotype in Europeans (OR=1.406, 95% CI=1.025-1.928, p=0.035). However, meta-analysis of all study subjects showed no association between PCOS and the MTHFR 677T allele (OR=0.998, 95% CI=0.762-1.307, p=0.989), including Europeans (OR=0.806, 95% CI=0.610-1.063, p=0.126). Meta-analysis showed no association between PCOS and the MTHFR 677C/T polymorphism using homozygote contrast, and recessive and dominant models. In conclusion, meta-analysis suggests the PAI-1 4G/5G polymorphism is associated with susceptibility to PCOS in European, Turkish, and Asian populations, but the MTHFR 677C/T polymorphism is not associated with susceptibility to PCOS in Europeans. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. Virtual non-contrast of liver from dual energy CT: a clinical application

    International Nuclear Information System (INIS)

    Qian Yu'e; Hu Hongjie; Zhang Qiaowei; Hu Peng; Shen Guohui

    2011-01-01

    Objective: To assess the virtual non-contrast liver CT from dual-energy CT for the clinical application. Methods: In total, 51 patients were included in the study, and all patients underwent multi-phase liver CT on a dual-source CT. The True non-contrast liver CT (TNCT) was performed in a single-energy acquisition mode, but the arterial and portovenous liver CT (VNCT) were performed in a dual- energy mode of 110 kV and 140 kV respectively. The virtual non-contrast CT images were derived from the arterial data using liver virtual non-contrast software. Between the true non-contrast CT and the virtual non- contrast CT, the image quality, mean CT HU values in the liver and muscle, signal to noise (SNR), the radiation dose of volume CT dose index (CTDIvol) and dose length product (DLP) in a single phase and total examination were compared with t test. Results: There was no significant difference in the detection of' liver lesions between TNCT and VNCT. The CT Hu values of muscle on both TNCT and VNCT images were almost equal. The CT HU values of liver on VNCT images were higher than that on TNCT images and the difference was significant [61.32±6.04 vs. (56.85±4.80) HU, t=-3.927, P<0.01]. There was also significant difference of SNR between TNCT (11.28±2.78) and VNCT (8.65±1.56) images (t=-5.590, P<0.01). The CTDIvol and DLP of single phase were (7.07±0.85) mGy and (155.11± 22.52) mGy · cm respectively in TNCT, and (7.05±0.87) mGy and (154.48±23.12) mGy · cm in VNCT. The total CTDIvol and DLP in VNCT were (14.35±1.66) mGy and (313.91±45.08) mGy · cm respectively, but in TNCT the total CTDIvol and DLP reached (21.43±2.46) mGy and (469.02± 66.22) mGy · cm. The difference of CTDIvol and DLP in single phase between TNCT and VNCT showed no significance, but the total CTDIvol and DLP were significantly different (t=16.168 and 13.132, P< 0.01). Conclusion: With the consequent reduction in radiation dose, the VNCT can replace TNCT as an imaging protocol in multi

  7. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: a comparison of CT and CT-MRI based tissue segmentation on simulated temperature.

    Science.gov (United States)

    Verhaart, René F; Fortunati, Valerio; Verduijn, Gerda M; van der Lugt, Aad; van Walsum, Theo; Veenland, Jifke F; Paulides, Margarethus M

    2014-12-01

    In current clinical practice, head and neck (H&N) hyperthermia treatment planning (HTP) is solely based on computed tomography (CT) images. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast over CT. The purpose of the authors' study is to investigate the relevance of using MRI in addition to CT for patient modeling in H&N HTP. CT and MRI scans were acquired for 11 patients in an immobilization mask. Three observers manually segmented on CT, MRI T1 weighted (MRI-T1w), and MRI T2 weighted (MRI-T2w) images the following thermo-sensitive tissues: cerebrum, cerebellum, brainstem, myelum, sclera, lens, vitreous humor, and the optical nerve. For these tissues that are used for patient modeling in H&N HTP, the interobserver variation of manual tissue segmentation in CT and MRI was quantified with the mean surface distance (MSD). Next, the authors compared the impact of CT and CT and MRI based patient models on the predicted temperatures. For each tissue, the modality was selected that led to the lowest observer variation and inserted this in the combined CT and MRI based patient model (CT and MRI), after a deformable image registration. In addition, a patient model with a detailed segmentation of brain tissues (including white matter, gray matter, and cerebrospinal fluid) was created (CT and MRIdb). To quantify the relevance of MRI based segmentation for H&N HTP, the authors compared the predicted maximum temperatures in the segmented tissues (Tmax) and the corresponding specific absorption rate (SAR) of the patient models based on (1) CT, (2) CT and MRI, and (3) CT and MRIdb. In MRI, a similar or reduced interobserver variation was found compared to CT (maximum of median MSD in CT: 0.93 mm, MRI-T1w: 0.72 mm, MRI-T2w: 0.66 mm). Only for the optical nerve the interobserver variation is significantly lower in CT compared to MRI (median MSD in CT: 0.58 mm, MRI-T1w: 1.27 mm, MRI-T2w: 1.40 mm). Patient models based on CT (Tmax: 38.0 °C) and CT and MRI

  8. Association Analysis between g.18873C>T and g.27522G>A Genetic Polymorphisms of OPG and Bone Mineral Density in Chinese Postmenopausal Women

    Directory of Open Access Journals (Sweden)

    Fei Wang

    2014-01-01

    Full Text Available Several studies report that the OPG is an important candidate gene in the pathogenesis of osteoporosis. This study aimed to detect the potential association of OPG gene polymorphisms with osteoporosis in postmenopausal women. We recruited 928 subjects containing 463 with primary postmenopausal osteoporosis and 465 healthy volunteers as controls. The BMD of neck hip, lumbar spine (L2–4, and total hip were assessed by dual-energy X-ray absorptiometry (DEXA. Through the created restriction site-polymerase chain reaction (CRS-PCR, PCR-restriction fragment length polymorphism (PCR-RFLP, and DNA sequencing methods, the g.18873C>T and g.27522G>A have been investigated. As for g.18873C>T, our data indicated that subjects with CC genotype have significantly higher BMD value than those of CT and TT genotypes (all P values A, the BMD values of subjects with GG genotype were significantly higher than those of GA and AA genotypes (all P values T and g.27522G>A genetic polymorphisms are associated with the decreased risk for osteoporosis in Chinese postmenopausal women.

  9. Modulation of nuclear T3 binding by T3 in a human hepatocyte cell-line (Chang-liver) - T3 stimulation of cell growth but not of malic enzyme, glucose-6-phosphatdehydrogenase or 6-phosphogluconate-dehydrogenase

    DEFF Research Database (Denmark)

    Matzen, L E; Kristensen, S R; Kvetny, J

    1991-01-01

    The T3 modulation of nuclear T3 binding (NBT3), the T3 effect on cell growth, and the T3 and insulin effects on malic enzyme (ME), glucose-6-phosphat-dehydrogenase (G6PD) and 6-phosphogluconat-dehydrogenase (G6PD) were studied in a human hepatocyte cell-line (Chang-liver). T3 was bound to a high ...

  10. Genetic analysis of the ELOVL6 gene polymorphism associated with type 2 diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y.; Wang, F.; Yu, X.L.; Miao, Z.M.; Wang, Z.C.; Chen, Y.; Wang, Y.G. [Department of Endocrinology, The Affiliated Hospital of Medical College, Qingdao University, Qingdao (China)

    2013-08-10

    Recent animal studies have indicated that overexpression of the elongation of long-chain fatty acids family member 6 (Elovl6) gene can cause insulin resistance and β-cell dysfunction. These are the major factors involved in the development of type 2 diabetes mellitus (T2DM). To identify the relationship between single nucleotide polymorphisms (SNP) of ELOVL6 and T2DM pathogenesis, we conducted a case-control study of 610 Han Chinese individuals (328 newly diagnosed T2DM and 282 healthy subjects). Insulin resistance and islet first-phase secretion function were evaluated by assessment of insulin resistance in a homeostasis model (HOMA-IR) and an arginine stimulation test. Three SNPs of the ELOVL6 gene were genotyped with polymerase chain reaction-restriction fragment length polymorphism, with DNA sequencing used to confirm the results. Only genotypes TT and CT of the ELOVL6 SNP rs12504538 were detected in the samples. Genotype CC was not observed. The T2DM group had a higher frequency of the C allele and the CT genotype than the control group. Subjects with the CT genotype had higher HOMA-IR values than those with the TT genotype. In addition, no statistical significance was observed between the genotype and allele frequencies of the control and T2DM groups for SNPs rs17041272 and rs6824447. The study indicated that the ELOVL6 gene polymorphism rs12504538 is associated with an increased risk of T2DM, because it causes an increase in insulin resistance.

  11. Genetic analysis of the ELOVL6 gene polymorphism associated with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Liu, Y.; Wang, F.; Yu, X.L.; Miao, Z.M.; Wang, Z.C.; Chen, Y.; Wang, Y.G.

    2013-01-01

    Recent animal studies have indicated that overexpression of the elongation of long-chain fatty acids family member 6 (Elovl6) gene can cause insulin resistance and β-cell dysfunction. These are the major factors involved in the development of type 2 diabetes mellitus (T2DM). To identify the relationship between single nucleotide polymorphisms (SNP) of ELOVL6 and T2DM pathogenesis, we conducted a case-control study of 610 Han Chinese individuals (328 newly diagnosed T2DM and 282 healthy subjects). Insulin resistance and islet first-phase secretion function were evaluated by assessment of insulin resistance in a homeostasis model (HOMA-IR) and an arginine stimulation test. Three SNPs of the ELOVL6 gene were genotyped with polymerase chain reaction-restriction fragment length polymorphism, with DNA sequencing used to confirm the results. Only genotypes TT and CT of the ELOVL6 SNP rs12504538 were detected in the samples. Genotype CC was not observed. The T2DM group had a higher frequency of the C allele and the CT genotype than the control group. Subjects with the CT genotype had higher HOMA-IR values than those with the TT genotype. In addition, no statistical significance was observed between the genotype and allele frequencies of the control and T2DM groups for SNPs rs17041272 and rs6824447. The study indicated that the ELOVL6 gene polymorphism rs12504538 is associated with an increased risk of T2DM, because it causes an increase in insulin resistance

  12. Genetic analysis of the ELOVL6 gene polymorphism associated with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Y. Liu

    2013-08-01

    Full Text Available Recent animal studies have indicated that overexpression of the elongation of long-chain fatty acids family member 6 (Elovl6 gene can cause insulin resistance and β-cell dysfunction. These are the major factors involved in the development of type 2 diabetes mellitus (T2DM. To identify the relationship between single nucleotide polymorphisms (SNP of ELOVL6 and T2DM pathogenesis, we conducted a case-control study of 610 Han Chinese individuals (328 newly diagnosed T2DM and 282 healthy subjects. Insulin resistance and islet first-phase secretion function were evaluated by assessment of insulin resistance in a homeostasis model (HOMA-IR and an arginine stimulation test. Three SNPs of the ELOVL6 gene were genotyped with polymerase chain reaction-restriction fragment length polymorphism, with DNA sequencing used to confirm the results. Only genotypes TT and CT of the ELOVL6 SNP rs12504538 were detected in the samples. Genotype CC was not observed. The T2DM group had a higher frequency of the C allele and the CT genotype than the control group. Subjects with the CT genotype had higher HOMA-IR values than those with the TT genotype. In addition, no statistical significance was observed between the genotype and allele frequencies of the control and T2DM groups for SNPs rs17041272 and rs6824447. The study indicated that the ELOVL6 gene polymorphism rs12504538 is associated with an increased risk of T2DM, because it causes an increase in insulin resistance.

  13. MR imaging and CT findings after liver transplantation

    International Nuclear Information System (INIS)

    Langer, M.; Langer, R.; Scholz, A.; Zwicker, C.; Astinet, F.

    1990-01-01

    The aim of the paper is to evaluate MR imaging and dynamic CT as noninvasive procedures to image signs of graft failure after an orthotopic liver transplantation (OLT). Thirty MR studies and 50 dynamic CT examinations were performed within 20 days after OLT. MR examinations were performed with a 0.5-T Siemens Magnetom. CT scans were obtained by using a Siemens Somatom Plus. In all patients, MR images demonstrated a perivascular rim of intermediate signal intensity on T1-weighted and increased signal intensity on T2-weighted images in the hilum of the liver; in 20/26, this was seen in peripheral areas also. In all patients, a perivascular area of low attenuation was diagnosed at angio-CT

  14. CT and MRI findings of Creutzfeldt-Jakob disease in the early stage. The usefulness of diffusion-weighted images

    International Nuclear Information System (INIS)

    Ukisu, Ryutaro; Kushihashi, Tamio; Gokan, Takehiko

    2001-01-01

    To detect subtle CT and MRI features of Creutzfeldt-Jacob disease (CJD) in the early stage is important to prevent a human-to-human transmission. This study included 10 patients of CJD who underwent CT and/or MRI in its early stage. CT, T1- and T2-weighted MRI, DWI, and FLAIR images were obtained in 10, 6, 4, and 2 patients respectively. On DWI, abnormal hyperintensities were observed in both cerebral cortex, and in basal ganglia in all patients. On FLAIR images, abnormal hyperintensies were observed in one patient. Detection of abnormal intensities may be possible in the early stage of CJD using MRI, particularly with DWI. (author)

  15. CT and MRI findings of Creutzfeldt-Jakob disease in the early stage. The usefulness of diffusion-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Ukisu, Ryutaro; Kushihashi, Tamio; Gokan, Takehiko [Showa Univ., Tokyo (Japan). School of Medicine] [and others

    2001-02-01

    To detect subtle CT and MRI features of Creutzfeldt-Jacob disease (CJD) in the early stage is important to prevent a human-to-human transmission. This study included 10 patients of CJD who underwent CT and/or MRI in its early stage. CT, T1- and T2-weighted MRI, DWI, and FLAIR images were obtained in 10, 6, 4, and 2 patients respectively. On DWI, abnormal hyperintensities were observed in both cerebral cortex, and in basal ganglia in all patients. On FLAIR images, abnormal hyperintensies were observed in one patient. Detection of abnormal intensities may be possible in the early stage of CJD using MRI, particularly with DWI. (author)

  16. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-01-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  17. CT and MRI findings of Madelung syndrome

    International Nuclear Information System (INIS)

    Liu Changhua; Zeng Yinglang; Zou Donglu; Wu Guihua

    2011-01-01

    Objective: To determine the CT and MR findings of Madelung syndrome. Methods: Five cases of Madelung syndrome were collected in our hospital from February 2006 to June 2009, including 3 cases of type Ⅰ Madelung syndrome and 2 cases of type Ⅱ Madelung syndrome. The 5 cases were all examined by CT, meanwhile 1 case by CT enhancement scanning and 2 cases by MR. The clinical characteristics and imaging manifestations were analyzed. Results: CT and MR images in 3 patients of type Ⅰ Madelung syndrome displayed fat accumulation within the subcutaneous tissue of the upper trunk and deep layer tissue of neck. The diffuse masses were located around the neck, upper chest and shoulders, which were called 'horse collar' and 'buffalo hump'. The other 2 cases of type Ⅱ Madelung syndrome displayed fat thickening within the subcutaneous tissue of the proximal extremities, anterior chest wall, showing special appearance of 'vigorous sailor'. All the 5 patients showed fat deposit within the subcutaneous tissue of the anterior rectus abdominis, inguina and fat accumulation within the scrotum. CT showed proliferated fat at the subcutaneous tissue of the involved regions. The CT value of proliferated fat were between - 30 and -70 HU. The proliferated fat tissue all could be displayed on MR T 1 WI, T 2 WI and T 2 WI fat suppression sequence, with typical hypointensity on T 1 WI and hyperintensity on T 2 WI, hypointensity on fat-suppression sequence and fibrous septation presenting among fat tissue. Conclusion: Combination with the history of long-term alcohol abuse, the Madelung syndrome could be diagnosed by CT and MR, which had great value in the surgical planning for identifying the extent of disease. (authors)

  18. Variabilidad genética de la respuesta inflamatoria: I. Polimorfismo -511 C/T en el gen IL1β en diferentes subpoblaciones peruanas

    Directory of Open Access Journals (Sweden)

    Óscar Acosta

    2012-07-01

    Full Text Available El polimorfismo -511 citosina/timina (-511 C/T en la región promotora del gen interleuquina 1 beta (IL1β estα implicado en la producciσn diferencial de la citoquina y por tanto puede estar asociado a la respuesta inmuno-inflamatoria en obesidad, dislipidemias, cardiopatías, cáncer, infecciones, y el tratamiento con nutrientes y fármacos. Objetivos: Establecer la distribución de frecuencias de los genotipos y alelos del polimorfismo -511 C/T del gen IL1β en diferentes subpoblaciones peruanas. Diseño: Estudio descriptivo, observacional, transversal. Instituciones: Centro de Investigación de Bioquímica y Nutrición e Instituto de Medicina Tropical D.A. Carrión, Facultad de Medicina, UNMSM y Centro de Genética y Biología Molecular, Facultad de Medicina, USMP, Lima, Perú. Participantes: Pobladores peruanos. Intervenciones: Extracción de ADN genómico a partir de muestras sanguíneas o epitelio bucal según metodología estándar, de 168 individuos de 9 grupos subpoblacionales: 23 mestizos de Lima, 33 amazónicos (20 de Pucallpa y 13 de Amazonas y 112 andinos (12 de Ancash, 10 de Cajamarca, 18 de Huarochirí-Lima, 25 de Puno-Taquile, 25 de Puno-Uros y 22 de Puno-Anapia. Análisis del polimorfismo -511 C/T mediante la técnica de PCR/RFLP, con primers específicos y digestión con la enzima de restricción AvaI, detectándose los fragmentos por electroforesis en geles de agarosa al 2% y tinción con bromuro de etidio. Principales medidas de resultados: Frecuencias genotípicas y alélicas del gen IL1β. Resultados: Se encontró las siguientes frecuencias genotípicas CC=0,024; CT=0,369 y TT=0,607, consistentes con el equilibrio de Hardy-Weinberg; y las frecuencias alélicas fueron alelo C=0,208 y aleloT= 0,792. La frecuencia del alelo T, considerado el mutante, fue muy alta en los Uros de Puno (0.940 y más baja en los mestizos de Lima (0.609. La comparación de las frecuencias genotípicas (TT versus CT+CC y alélicas (T versus C

  19. CT characteristics and pathological implications of early stage (T1N0M0) lung adenocarcinoma with pure ground-glass opacity

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Xin; Zhao, Shao-hong; Wu, Jian; Wu, Chong-chong; Chang, Rui-ping; Ju, Hai-yue [Chinese PLA General Hospital, Department of Radiology, Beijing (China); Gao, Jie; Wang, Dian-jun [Chinese PLA General Hospital, Department of Pathology, Beijing (China)

    2015-09-15

    To analyze the CT characteristics and pathological classification of early lung adenocarcinoma (T1N0M0) with pure ground-glass opacity (pGGO). Ninety-four lesions with pGGO on CT in 88 patients with T1N0M0 lung adenocarcinoma were selected from January 2010 to December 2012. All lesions were confirmed by pathology. CT appearances were analyzed including lesion location, size, density, uniformity, shape, margin, tumour-lung interface, internal and surrounding malignant signs. Lesion size and density were compared using analysis of variance, lesion size also assessed using ROC curves. Gender of patients, lesion location and CT appearances were compared using χ2-test. There were no significant differences in gender, lesion location and density with histological invasiveness (P > 0.05). The ROC curve showed that the possibility of invasive lesion was 88.73 % when diameter of lesion was more than 10.5 mm. There was a significant difference between lesion uniformity and histological invasiveness (P = 0.01). There were significant differences in margin, tumour-lung interface, air bronchogram with histological invasiveness (P = 0.02,P = 0.00,P = 0.048). The correlation index of lesion size and uniformity was r = 0.45 (P = 0.00). The lesion size and uniformity, tumour-lung interface and the air bronchogram can help predict invasive extent of early stage lung adenocarcinoma with pGGO. (orig.)

  20. CT volumetry for gastric carcinoma: association with TNM stage.

    Science.gov (United States)

    Hallinan, James T P D; Venkatesh, Sudhakar K; Peter, Luke; Makmur, Andrew; Yong, Wei Peng; So, Jimmy B Y

    2014-12-01

    We evaluated the feasibility of performing CT volumetry of gastric carcinoma (GC) and its correlation with TNM stage. This institutional review board-approved retrospective study was performed on 153 patients who underwent a staging CT study for histologically confirmed GC. CT volumetry was performed by drawing regions of interest including abnormal thickening of the stomach wall. Reproducibility of tumour volume (Tvol) between two readers was assessed. Correlation between Tvol and TNM/peritoneal staging derived from histology/surgical findings was evaluated using ROC analysis and compared with CT evaluation of TNM/peritoneal staging. Tvol was successfully performed in all patients. Reproducibility among readers was excellent (r = 0.97; P = 0.0001). The median Tvol of GC showed an incremental trend with T-stage (T1 = 27 ml; T2 = 32 ml; T3 = 53 ml and T4 = 121 ml, P volumetry may provide useful adjunct information for preoperative staging of GC. CT volumetry of gastric carcinoma is feasible and reproducible. Tumour volume 95.7 ml predicts metastatic gastric cancer with 87% sensitivity and 78.5% specificity (P = 0.0001). CT volumetry may be a useful adjunct for staging gastric carcinoma.

  1. CT and MRI diagnosis of renal oncocytoma

    International Nuclear Information System (INIS)

    Ren Shoujun; Wang Wenjia; Pan Shaohui; Gao Ji; Du Pengfei; Lu Fengxi; Wang Xiaohong

    2007-01-01

    Objective: To discuss the CT and MRI diagnostic value of renal oncocytoma and to improve the recognition of renal oncocytoma. Methods: Two cases of renal oncocytoma confirmed by pathology were retrospectively analyzed and related papers were reviewed. Results: Two cases were located in renal cortex, with smooth and sharp border, extruding outside of the kidneys. CT showed solid masses with lower density in center area as 'star'. On MRI T 1 WI and T 2 WI they also showed solid masses with low T 1 and high T 2 signal inensity in center area as 'star'. After contrast enhancement, the masses represented moderate enhancement and the central part did not show enhancement. Conclusion: Renal oncocytoma is a kind of rare nephroma provided with some characteristics in CT and MRI. (authors)

  2. 68Ga-PSMA and 11C-Choline comparison using a tri-modality PET/CT-MRI (3.0 T) system with a dedicated shuttle.

    Science.gov (United States)

    Alonso, Omar; Dos Santos, Gerardo; García Fontes, Margarita; Balter, Henia; Engler, Henry

    2018-01-01

    The aim of this study was to prospectively compare the detection rate of 68 Ga-PSMA versus 11 C-Choline in men with prostate cancer with biochemical recurrence and to demonstrate the added value of a tri-modality PET/CT-MRI system. We analysed 36 patients who underwent both 11 C-Choline PET/CT and 68 Ga-PSMA PET/CT scanning within a time window of 1-2 weeks. Additionally, for the 68 Ga-PSMA scan, we used a PET/CT-MRI (3.0 T) system with a dedicated shuttle, acquiring MRI images of the pelvis. Both scans were positive in 18 patients (50%) and negative in 8 patients (22%). Nine patients were positive with 68 Ga-PSMA alone (25%) and one with 11 C-Choline only (3%). The median detected lesion per patient was 2 for 68 Ga-PSMA (range 0-93) and 1 for 11 C-Choline (range 0-57). Tumour to background ratios in all concordant lesions ( n  = 96) were higher for 68 Ga-PSMA than for 11 C-Choline (110.3 ± 107.8 and 27.5 ± 17.1, mean ± S.D., for each tracer, respectively P  = 0.0001). The number of detected lesions per patient was higher for 11 C-Choline in those with PSA ≥ 3.3 ng/mL, while the number of detected lesions was independent of PSA levels for 68 Ga-PSMA using the same PSA cut-off value. Metastatic pelvic lesions were found in 25 patients (69%) with 68 Ga-PSMA PET/CT, in 18 (50%) with 11 C-Choline PET/CT and in 21 (58%) with MRI (3.0 T). MRI was very useful in detecting recurrence in cases classified as indeterminate by means of PET/CT alone at prostate bed. In patients with prostate cancer with biochemical recurrence 68 Ga-PSMA detected more lesions per patient than 11 C-Choline, regardless of PSA levels. PET/CT-MRI (3.0 T) system is a feasible imaging modality that potentially adds useful relevant information with increased accuracy of diagnosis.

  3. TERT-CLPTM1L Rs401681 C>T polymorphism was associated with a decreased risk of esophageal cancer in a Chinese population.

    Directory of Open Access Journals (Sweden)

    Jun Yin

    Full Text Available BACKGROUND: Esophageal cancer was the fifth most commonly diagnosed cancer and the fourth leading cause of cancer-related death in China in 2009. Esophageal squamous cell carcinoma (ESCC accounts for more than 90 percent of esophageal cancers. Genetic factors probably play an important role in the ESCC carcinogenesis. METHODS: We conducted a hospital based case-control study to evaluate functional hTERT rs2736098 G>A and TERT-CLPTM1L rs401681 C>T single nucleotide polymorphisms (SNPs on the risk of ESCC. Six hundred and twenty-nine ESCC cases and 686 controls were recruited. Their genotypes were determined using the ligation detection reaction (LDR method. RESULTS: When the TERT-CLPTM1L rs401681 CC homozygote genotype was used as the reference group, the CT genotype was associated with a significantly decreased risk of ESCC (adjusted OR  = 0.74, 95% CI  = 0.58-0.94, p = 0.012; the CT/TT variants were associated with a 26% decreased risk of ESCC (adjusted OR  = 0.74, 95% CI  = 0.59-0.93, P = 0.009. The significantly decreased risk of ESCC associated with the TERT-CLPTM1L rs401681 C>T polymorphism was associated with male sex, young age (A polymorphism and ESCC risk was observed. CONCLUSION: TERT-CLPTM1L rs401681 CT and CT/TT genotypes were associated with decreased risk of ESCC, particularly among men, young patients and those reported to be drinkers. However, our results are preliminary conclusions. Larger studies with more rigorous study designs are required to confirm the current findings.

  4. CT-Guided, Ethanol Sympatholysis for Primary Axillary–Palmar Hyperhidrosis

    Energy Technology Data Exchange (ETDEWEB)

    Tsitskari, Maria, E-mail: mariadote@hotmail.com [American Medical Center, Vascular & Interventional Radiology (Cyprus); Friehs, Gerhard, E-mail: gerhardf@amc.com.cy; Zerris, Vassilis, E-mail: vassilisz@amc.com.cy [American Medical Center, Neurosurgery (Cyprus); Georgiades, Christos, E-mail: g-christos@hotmail.com [Johns Hopkins Hospital, Vascular & Interventional Radiology (United States)

    2016-12-15

    PurposePrimary hyperhidrosis is an excessive sweating due to an overactive sympathetic system. Our objective was to test the feasibility and provide early data on the safety/efficacy of CT-guided sympatholysis, for primary hyperhidrosis.Materials and MethodsNine consecutive patients with axillary–palmar hyperhidrosis were treated between 2013 and 2015. CT-guided sympathetic block was performed in the outpatients at T-2, T-3, and T-4, bilaterally using alcohol under local anesthesia. Immediate postprocedure CT was obtained to assess the complications as per Common Terminology Criteria for Adverse Events, version 4. Technical success and clinical success were recorded. Primary and secondary efficacy were assessed by phone and clinical visits; mean follow-up was 12 months (6–26 months). Descriptive statistics was used to report the outcomes.ResultsOne procedure was aborted due to eyelid ptosis after lidocaine injection. All other eight patients (5:3, F:M) (median age 32) had immediate cessation of sweating. Two major complications (pneumothorax, one requiring a chest tube) occurred. Two patients recurred with unilateral and one with bilateral symptoms. One of the unilateral recurrence and the bilateral recurrence patients was retreated successfully. Median follow-up was 1 year. No cases of Horner’s or compensatory hyperhidrosis were observed.ConclusionsCT-guided EtOH sympatholysis for axillary/palmar primary hyperhidrosis is feasible. Technical failure rate was 11 %. Primary and secondary efficacy are 75 and 94 %, respectively, to a median follow-up of 1 year. Risk profile appears favorable. Despite a small sample size, results confirm feasibility and encourage a larger study.

  5. Irradiation and postirradiation storage at 2 +/- 2 degrees C of tilapia (Tilapia nilotica X T. aurea) and Spanish mackeral (Scomberomorus commerson): sensory and microbial assessment

    International Nuclear Information System (INIS)

    Abu-Tarboush, H.M.; Al-Kahtani, H.A.; Atia, M.; Abou-Arab, A.A.; Bajaber, A.S.; El-Mojaddidi, M.A.

    1996-01-01

    Tilapia (low-fat farm fish, Tilapia nilotica X T. aurea) and Spanish mackerel (high-fat seawater fish, Scomberomorus commerson) were subjected to gamma irradiation doses of 1.5, 3.0, 4.5, 6.0, and 10.0 kGy by using a semicommercial gamma irradiator. The irradiated and unirradiated (controls) fish were stored at 2 +/- 2 degrees C and samples were drawn at day 0, 4, 8, 12, 16, and 20 for sensory evaluation and microbiological analysis. Doses of 3.0 and/or 4.5 kGy extended the sensory acceptability (appearance, odor, texture, taste) and the microbial quality (total count and coliforms) by 8 days compared to the unirradiated controls. Hydrogen sulfide-producing bacteria were low in both types of fish and a dose of 1.5 kGy kept this flora at low levels throughout the storage period. Moreover, this dose level was also sufficient to eliminate Salmonella spp. from both fish. Yersinia and Campylobacter species were effectively eliminated by doses of 1.5 and 3.0 kGy. Doses of 6.0 and 10.0 kGy caused a reduction in psychrotrophic counts but were detrimental to the quality of both species of fish

  6. Central nervous system involvement of leukemia and systemic lymphoma in children. CT and MR findings

    International Nuclear Information System (INIS)

    Tomura, Noriaki; Hirano, Hiroko; Kato, Kohki; Sashi, Ryuji; Hashimoto, Manabu; Watarai, Jiro; Watanabe, Arata

    1997-01-01

    The purpose of this paper is to retrospectively evaluate CT and MR findings of central nervous system (CNS) involvement of leukemia and systemic lymphoma in children. Over a 12-year period, sixty-five patients with leukemia and fifteen patients with systemic lymphoma underwent cerebral CT and/or MR imaging. Nine patients were diagnosed as CNS involvement of leukemia and lymphoma. The CT and MR abnormalities in these patients were correlated with the findings of histology, cerebrospinal fluid cytology, and/or treatment. The age of the patients ranged from 0 to 15 years old. They consisted of 6 boys and 3 girls. The CT examinations were performed before and after contrast administration. MR examinations were performed on a 1.5-T unit, and T1-weighted, T2-weighted, and proton density-weighted images were obtained using spin-echo or fast spin-echo sequences. Tumor masses were present in seven with leukemia, and in two with malignant lymphoma. On the CT scan, tumor masses were hyperdense with contrast enhancement. On the MR images, their signals were variable. In all of nine patients, tumor masses were contiguous with a meningeal surface. Postcontrast T1-weighted images were valuable in demonstrating meningeal infiltration. Tumoral hemorrhage was found in two patients. In a patient with tumor at the superior sagittal sinus, venous infarct was observed. CNS leukemic and lymphomatous masses are almost hyperdense on the CT and they are characteristically contiguous with a meningeal surface. MR imaging was valuable in demonstrating meningeal infiltration. (K.H.)

  7. Elimination of self-reactive CD8+, but not CD4+, T cells by a peripheral immune mechanism

    International Nuclear Information System (INIS)

    Rammensee, H.G.; Huegin, D.

    1990-01-01

    Unirradiated (BALB/c X B6)F1 recipients of lymphocytes from either parent or (B6 X DBA/2)F2 recipients of DBA/2 parental lymphocytes specifically remove the function of donor-derived F1-reactive CTL from the spleen, since such cells could not be recovered 1 week after injection. However, donor-derived CTL specific for third-party antigens, as well as donor-derived F1-reactive CD4+ T cells could be recovered. In contrast, CTL in spleens from recipients sublethally irradiated prior to injections consisted predominantly of F1-reactive CTL in all strain combinations tested. Athymic BALB/c nude mice grafted with fetal thymus of B6 develop a T cell compartment tolerant of BALB/c and B6, like (BALB/c X B6)F1 animals. However, unlike the F1 mice, the thymus-grafted nude mice were not able to eliminate B6-reactive lymphocytes after injection of normal BALB/c spleen cells. Our data indicate the existence of a peripheral immune mechanism capable of selectively eliminating self-reactive CD8+ CTL, but not CD4+, T cells. This mechanism requires self antigen expressed on radiosensitive cells. The presence of T cells tolerant to self antigen by thymic negative selection is not sufficient and perhaps not required. Most likely, this mechanism is involved in the relative resistance to lethal GVHR mediated by parental CD8+ T cells in parent-into-F1 situations

  8. Lack of autologous mixed lymphocyte reaction in patients with chronic lymphocytic leukemia: evidence for autoreactive T-cell dysfunction not correlated with phenotype, karyotype, or clinical status

    International Nuclear Information System (INIS)

    Han, T.; Bloom, M.L.; Dadey, B.; Bennett, G.; Minowada, J.; Sandberg, A.A.; Ozer, H.

    1982-01-01

    In the present study, there was a complete lack of autologous MLR between responding T cells or T subsets and unirradiated or irradiated leukemic B cells or monocytes in all 20 patients with CLL, regardless of disease status, stage, phenotype, or karyotype of the disease. The stimulating capacity of unirradiated CLL B cells and CLL monocytes or irradiated CLL B cells was significantly depressed as compared to that of respective normal B cells and monocytes in allogeneic MLR. The responding capacity of CLL T cells was also variably lower than that of normal T cells against unirradiated or irradiated normal allogeneic B cells and monocytes. The depressed allogeneic MLR between CLL B cells or CLL monocytes and normal T cells described in the present study could be explained on the basis of a defect in the stimulating antigens of leukemic B cells or monocytes. The decreased allogeneic MLR of CLL T cells might simply be explained by a defect in the responsiveness of T lymphocytes from patients with CLL. However, these speculations do not adequately explain the complete lack of autologous MLR in these patients. When irradiated CLL B cells or irradiated CLL T cells were cocultured with normal T cells and irradiated normal B cells, it was found that there was no suppressor cell activity of CLL B cells or CLL T cells on normal autologous MLR. Our data suggest that the absence or dysfunction of autoreactive T cells within the Tnon-gamma subset account for the lack of autologous MLR in patients with CLL. The possible significance of the autologous MLR, its relationship to in vivo immunoregulatory mechanisms, and the possible role of breakdown of autoimmunoregulation in the oncogenic process of certain lymphoproliferative and autoimmune diseases in man are discussed

  9. Role of combined DWIBS/3D-CE-T1w whole-body MRI in tumor staging: Comparison with PET-CT

    International Nuclear Information System (INIS)

    Manenti, Guglielmo; Cicciò, Carmelo; Squillaci, Ettore; Strigari, Lidia; Calabria, Ferdinando; Danieli, Roberta

    2012-01-01

    Objectives: To assess the diagnostic performance of whole-body magnetic resonance imaging (WB-MRI) by diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) in malignant tumor detection and the potential diagnostic advantages in generating fused DWIBS/3D-contrast enhanced T1w (3D-CE-T1w) images. Methods: 45 cancer patients underwent 18F-FDG PET-CT and WB-MRI for staging purpose. Fused DWIBS/3D-CE T1w images were generated off-line. 3D-CE-T1w, DWIBS images alone and fused with 3D-CE T1w were compared by two readers groups for detection of primary diseases and local/distant metastases. Diagnostic performance between the three WB-MRI data sets was assessed using receiver operating characteristic (ROC) curve analysis. Imaging exams and histopathological results were used as standard of references. Results: Areas under the ROC curves of DWIBS vs. 3D-CE-T1w vs. both sequences in fused fashion were 0.97, 0.978, and 1.00, respectively. The diagnostic performance in tumor detection of fused DWIBS/3D-CE-T1w images were statistically superior to DWIBS (p < 0.001) and 3D-CE-T1w (p ≤ 0.002); while the difference between DWIBS and 3D-CE-T1w did not show statistical significance difference. Detection rates of malignancy did not differ between WB-MRI with DWIBS and 18F-FDG PET-CT. Conclusion: WB-MRI with DWIBS is to be considered as alternative tool to conventional whole-body methods for tumor staging and during follow-up in cancer patients.

  10. Effects of the lactase 13910 C/T and calcium-sensor receptor A986S G/T gene polymorphisms on the incidence and recurrence of colorectal cancer in Hungarian population

    Directory of Open Access Journals (Sweden)

    Budai Barna

    2008-11-01

    Full Text Available Abstract Background Epidemiological studies suggested the chemopreventive role of higher calcium intake in colorectal carcinogenesis. We examined genetic polymorphisms that might influence calcium metabolism: lactase (LCT gene 13910 C/T polymorphism causing lactose intolerance and calcium-sensing receptor (CaSR gene A986S polymorphism as a responsible factor for the altered cellular calcium sensation. Methods 538 Hungarian subjects were studied: 278 patients with colorectal cancer and 260 healthy controls. Median follow-up was 17 months. After genotyping, the relationship between LCT 13910 C/T and CaSR A986S polymorphisms as well as tumor incidence/progression was investigated. Results in patient with colorectal cancer, a significantly higher LCT CC frequency was associated with increased distant disease recurrence (OR = 4.04; 95% CI = 1.71–9.58; p = 0.006. The disease free survival calculated from distant recurrence was reduced for those with LCT CC genotype (log rank test p = 0.008. In case of CaSR A986S polymorphism, the homozygous SS genotype was more frequent in patients than in controls (OR = 4.01; 95% CI = 1.33–12.07; p = 0.014. The number of LCT C and CaSR S risk alleles were correlated with tumor incidence (p = 0.035. The CCSS genotype combination was found only in patients with CRC (p = 0.033. Conclusion LCT 13910 C/T and CaSR A986S polymorphisms may have an impact on the progression and/or incidence of CRC.

  11. Comparison of Quick Lactose Intolerance Test in duodenal biopsies of dyspeptic patients with single nucleotide polymorphism LCT-13910C>T associated with primary hypolactasia/lactase-persistence.

    Science.gov (United States)

    Mattar, Rejane; Basile-Filho, Anibal; Kemp, Rafael; Santos, José Sebastião dos

    2013-01-01

    To analyze the usefulness of Quick Lactose Intolerance Test in relation to the genetic test based on LCT-13910C>T genotypes, previously validated for clinical practice, for primary hypolactasia/lactase-persistence diagnosis. Thirty-two dyspeptic patients that underwent upper gastrointestinal endoscopy entered the study. Two postbulbar duodenal biopsies were taken for the Quick test, and gastric antral biopsy for DNA extraction and LCT-13910C>T polymorphism analysis. DNA was also extracted from biopsies after being used in the Quick Test that was kept frozen until extraction. Nine patients with lactase-persistence genotype (LCT-13910CT or LCT-13910TT) had normolactasia, eleven patients with hypolactasia genotype (LCT-13910CC) had severe hypolactasia, and among twelve with mild hypolactasia, except for one that had LCT-13910CT genotype, all the others had hypolactasia genotype. The agreement between genetic test and quick test was high (plactose-containing food ingestion had severe hypolactasia (plactose intolerance.

  12. SU-F-T-626: Intracranial SRS Re-Treatment Without Acquisition of New CT Images

    International Nuclear Information System (INIS)

    Wiant, D; Manning, M; Liu, H; Maurer, J; Hayes, T; Sintay, B

    2016-01-01

    Purpose: Linear accelerator based stereotactic radiosurgery (SRS) for multiple intracranial lesions with frequent surveillance is becoming a popular treatment option. This strategy leads to retreatment with SRS as new lesions arise. Currently, each course of treatment uses magnetic resonance (MR) and computed tomography (CT) images for treatment planning. We propose that new MR images, with course 1 CT images, may be used for future treatment plans with negligible loss of dosimetric accuracy. Methods: Ten patients that received multiple courses of SRS were retrospectively reviewed. The treatment plans and contours from non-initial courses were copied to the initial CTs and recalculated. Doses metrics for the plans calculated on the initial CTs and later CTs were compared. All CT scans were acquired on a Philips CT scanner with a 600 mm field of view and 1 mm slice thickness (Philips Healthcare, Andover, MA). All targets were planned to 20 Gy and calculated in Eclipse V. 13.6 (Varian, Palo Alto, CA) using analytic anisotropic algorithm with 1 mm calculation grid. Results: Sixteen lesions were evaluated. The mean time between courses was 250 +/− 215 days (range 103–979). The mean target volume was 2.0 +/− 2.9 cc (range 0.1–10.1). The average difference in mean target dose between the two calculations was 0.2 +/− 0.3 Gy (range 0.0 – 1.0). The mean conformity index (CI) was 1.28 +/− 0.14 (range 1.07 – 1.82). The average difference in CI was 0.03 +/− 0.16 (range 0.00 – 0.44). Targets volumes < 0.5 cc showed the largest changes in both metrics. Conclusion: Continued treatment based on initial CT images is feasible. Dose calculation on the initial CT for future treatments provides reasonable dosimetric accuracy. Changes in dose metrics are largest for small volumes, and are likely dominated by partial volume effects in target definition.

  13. Myocardial delayed-enhancement CT: initial experience in children and young adults

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2017-10-15

    Clinical utility of myocardial delayed enhancement CT has not been reported in children and young adults. To describe initial experience of myocardial delayed enhancement CT regarding image quality, radiation dose and identification of myocardial lesions in children and young adults. Between August 2013 and November 2016, 29 consecutive children and young adults (median age 16 months) with suspected coronary artery or myocardial abnormality underwent arterial- and delayed-phase cardiac CT at our institution. We measured CT densities in normal myocardium, left ventricular cavity, and arterial and delayed hypo-enhancing and delayed hyperenhancing myocardial lesions. We then compared the extent of delayed hyperenhancing lesions with delayed-enhancement MRI or thallium single-photon emission CT. Normal myocardium and left ventricular cavity showed significantly higher CT numbers on arterial-phase CT than on delayed-phase CT (t-test, P<0.0001). Contrast-to-noise ratios of the arterial and delayed hypo-enhancing and delayed hyperenhancing lesions on CT were 26.7, 17.6 and 18.7, respectively. Delayed-phase CT findings were equivalent to those of delayed-enhancement MRI in all cases (7/7) and to those of thallium single-photon emission CT in 70% (7/10). Myocardial delayed-enhancement CT can be added to evaluate myocardial lesions in select children and young adults with suspected coronary artery or myocardial abnormality. (orig.)

  14. Myocardial delayed-enhancement CT: initial experience in children and young adults

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2017-01-01

    Clinical utility of myocardial delayed enhancement CT has not been reported in children and young adults. To describe initial experience of myocardial delayed enhancement CT regarding image quality, radiation dose and identification of myocardial lesions in children and young adults. Between August 2013 and November 2016, 29 consecutive children and young adults (median age 16 months) with suspected coronary artery or myocardial abnormality underwent arterial- and delayed-phase cardiac CT at our institution. We measured CT densities in normal myocardium, left ventricular cavity, and arterial and delayed hypo-enhancing and delayed hyperenhancing myocardial lesions. We then compared the extent of delayed hyperenhancing lesions with delayed-enhancement MRI or thallium single-photon emission CT. Normal myocardium and left ventricular cavity showed significantly higher CT numbers on arterial-phase CT than on delayed-phase CT (t-test, P<0.0001). Contrast-to-noise ratios of the arterial and delayed hypo-enhancing and delayed hyperenhancing lesions on CT were 26.7, 17.6 and 18.7, respectively. Delayed-phase CT findings were equivalent to those of delayed-enhancement MRI in all cases (7/7) and to those of thallium single-photon emission CT in 70% (7/10). Myocardial delayed-enhancement CT can be added to evaluate myocardial lesions in select children and young adults with suspected coronary artery or myocardial abnormality. (orig.)

  15. Early dynamic imaging in "6"8Ga- PSMA-11 PET/CT allows discrimination of urinary bladder activity and prostate cancer lesions

    International Nuclear Information System (INIS)

    Uprimny, Christian; Kroiss, Alexander Stephan; Decristoforo, Clemens; Warwitz, Boris; Scarpa, Lorenza; Roig, Llanos Geraldo; Kendler, Dorota; Guggenberg, Elisabeth von; Virgolini, Irene Johanna; Fritz, Josef; Bektic, Jasmin; Horninger, Wolfgang

    2017-01-01

    PET/CT with "6"8Ga-labelled prostate-specific membrane antigen (PSMA)-ligands has been proven to establish a promising imaging modality in the work-up of prostate cancer (PC) patients with biochemical relapse. Despite a high overall detection rate, the visualisation of local recurrence may be hampered by high physiologic tracer accumulation in the urinary bladder on whole body imaging, usually starting 60 min after injection. This study sought to verify whether early dynamic "6"8Ga-PSMA-11 (HBED-CC)PET/CT can differentiate pathologic PC-related tracer uptake from physiologic tracer accumulation in the urinary bladder. Eighty consecutive PC patients referred to "6"8Ga -PSMA-11 PET/CT were included in this retrospective analysis (biochemical relapse: n = 64; primary staging: n = 8; evaluation of therapy response/restaging: n = 8). In addition to whole-body PET/CT acquisition 60 min post injection early dynamic imaging of the pelvis in the first 8 min after tracer injection was performed. SUV_m_a_x of pathologic lesions was calculated and time-activity curves were generated and compared to those of urinary bladder and areas of physiologic tracer uptake. A total of 55 lesions consistent with malignancy on 60 min whole body imaging exhibited also pathologic "6"8Ga-PSMA-11 uptake during early dynamic imaging (prostatic bed/prostate gland: n = 27; lymph nodes: n = 12; bone: n = 16). All pathologic lesions showed tracer uptake within the first 3 min, whereas urinary bladder activity was absent within the first 3 min of dynamic imaging in all patients. Suv_m_a_x was significantly higher in PC lesions in the first 6 min compared to urinary bladder accumulation (p < 0.001). In the subgroup of PC patients with biochemical relapse the detection rate of local recurrence could be increased from 20.3 to 29.7%. Early dynamic imaging in "6"8Ga-PSMA-11 PET/CT reliably enables the differentiation of pathologic tracer uptake in PC lesions from physiologic bladder accumulation

  16. Hydro-dynamic CT preoperative staging of gastric cancer: correlation with pathological findings. A prospective study of 107 cases

    International Nuclear Information System (INIS)

    D'Elia, F.; Zingarelli, A.; Grani, M.; Palli, D.

    2000-01-01

    The aim of this study was to evaluate the accuracy of dynamic CT in the preoperative staging of gastric cancer. One hundred seven patients affected by gastric cancer diagnosed by endoscopic biopsy were prospectively staged by dynamic CT prior to tumor resection. After an oral intake of 400-600 ml of tap water and an intravenous infusion of a hypotonic agent, 200 ml of non-ionic contrast agent were administered by power injector using a biphasic technique. The CT findings were prospectively analyzed and correlated with the pathological findings at surgery. The accuracy of dynamic CT for tumor detection was 80 and 99 % in early and advanced gastric cancer, respectively, with overall detection rate of 96 % (103 of 107). Three early (pT1) and one advanced (pT2) cancers were undetected. Tumor stage as determined by dynamic CT agreed with pathological findings in 83 of 107 patients with an overall accuracy of 78 %. The accuracy of CT in detecting increasing degrees of depth of tumor invasion when compared with pathological TNM staging was 20 % (3 of 15) and 87 % (80 of 92) in early and advanced cancer, respectively. The sensitivity, specificity, and accuracy of CT in the preoperative staging (pT3-pT4 vs pT1-pT2) was 93, 90, and 91.6 %, respectively. The sensitivity, specificity, and accuracy of CT in assessing metastasis to regional lymph nodes was 97.2, 65.7, and 87 %, respectively. Computed tomography correctly staged liver metastases in 105 of 107 patients with an overall sensitivity of 87.5 % and specificity of 99 %. The sensitivity of peritoneal involvement was 30 % when ascites or peritoneal nodules were absent. Our findings show that dynamic CT can play a role in the preoperative definition of gastric cancer stage. The results can be used to optimize the therapeutic strategy for each individual patient prior to surgery, thus avoiding unnecessary intervention and allowing careful planning of extended surgery in eligible patients. (orig.)

  17. Single-portal-phase low-tube-voltage dual-energy CT for short-term follow-up of acute pancreatitis: evaluation of CT severity index, interobserver agreement and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Wichmann, Julian L. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Universitaetsklinikum Frankfurt, Institut fuer Diagnostische und Interventionelle Radiologie, Frankfurt am Main (Germany); Majenka, Pawel; Beeres, Martin; Kromen, Wolfgang; Schulz, Boris; Bauer, Ralf W.; Kerl, J.M.; Gruber-Rouh, Tatjana; Hammerstingl, Renate; Vogl, Thomas J.; Lehnert, Thomas [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Wesarg, Stefan [Fraunhofer IGD, Cognitive Computing and Medical Imaging, Darmstadt (Germany)

    2014-11-15

    To intra-individually compare single-portal-phase low-tube-voltage (100-kVp) computed tomography (CT) with 120-kVp images for short-term follow-up assessment of CT severity index (CTSI) of acute pancreatitis, interobserver agreement and radiation dose. We retrospectively analysed 66 patients with acute pancreatitis who underwent initial dual-contrast-phase CT (unenhanced, arterial, portal phase) at admission and short-term (mean interval 11.4 days) follow-up dual-contrast-phase dual-energy CT. The 100-kVp and linearly blended images representing 120-kVp acquisition follow-up CT images were independently evaluated by three radiologists using a modified CTSI assessing pancreatic inflammation, necrosis and extrapancreatic complications. Scores were compared with paired t test and interobserver agreement was evaluated using intraclass correlation coefficients (ICC). Mean CTSI scores on unenhanced, portal- and dual-contrast-phase images were 4.9, 6.1 and 6.2 (120 kVp) and 5.0, 6.0 and 6.1 (100 kVp), respectively. Contrast-enhanced series showed a higher CTSI compared to unenhanced images (P < 0.05) but no significant differences between single- and dual-contrast-phase series (P > 0.7). CTSI scores were comparable for 100-kVp and 120-kVp images (P > 0.05). Interobserver agreement was substantial for all evaluated series and subcategories (ICC 0.67-0.93). DLP of single-portal-phase 100-kVp images was reduced by 41 % compared to 120-kVp images (363.8 versus 615.9 mGy cm). Low-tube-voltage single-phase 100-kVp CT provides sufficient information for follow-up evaluation of acute pancreatitis and significantly reduces radiation exposure. (orig.)

  18. Regression and statistical shape model based substitute CT generation for MRI alone external beam radiation therapy from standard clinical MRI sequences

    Science.gov (United States)

    Ghose, Soumya; Greer, Peter B.; Sun, Jidi; Pichler, Peter; Rivest-Henault, David; Mitra, Jhimli; Richardson, Haylea; Wratten, Chris; Martin, Jarad; Arm, Jameen; Best, Leah; Dowling, Jason A.

    2017-11-01

    In MR only radiation therapy planning, generation of the tissue specific HU map directly from the MRI would eliminate the need of CT image acquisition and may improve radiation therapy planning. The aim of this work is to generate and validate substitute CT (sCT) scans generated from standard T2 weighted MR pelvic scans in prostate radiation therapy dose planning. A Siemens Skyra 3T MRI scanner with laser bridge, flat couch and pelvic coil mounts was used to scan 39 patients scheduled for external beam radiation therapy for localized prostate cancer. For sCT generation a whole pelvis MRI (1.6 mm 3D isotropic T2w SPACE sequence) was acquired. Patients received a routine planning CT scan. Co-registered whole pelvis CT and T2w MRI pairs were used as training images. Advanced tissue specific non-linear regression models to predict HU for the fat, muscle, bladder and air were created from co-registered CT-MRI image pairs. On a test case T2w MRI, the bones and bladder were automatically segmented using a novel statistical shape and appearance model, while other soft tissues were separated using an Expectation-Maximization based clustering model. The CT bone in the training database that was most ‘similar’ to the segmented bone was then transformed with deformable registration to create the sCT component of the test case T2w MRI bone tissue. Predictions for the bone, air and soft tissue from the separate regression models were successively combined to generate a whole pelvis sCT. The change in monitor units between the sCT-based plans relative to the gold standard CT plan for the same IMRT dose plan was found to be 0.3%+/-0.9% (mean  ±  standard deviation) for 39 patients. The 3D Gamma pass rate was 99.8+/-0.00 (2 mm/2%). The novel hybrid model is computationally efficient, generating an sCT in 20 min from standard T2w images for prostate cancer radiation therapy dose planning and DRR generation.

  19. Indications for chest CT. Retrospective study of cases with normal chest CT

    International Nuclear Information System (INIS)

    Obata, Shiro

    1995-01-01

    The usefulness of computed tomography (CT) in thoracic radiology is now well appreciated, and the number of chest CTs has greatly increased. There are, however, many chest CT cases that are completely or almost completely normal. Indications for chest CT should be re-evaluated considering the cost and radiation exposure associated with the examination. Reviewing the reports of 4930 chest CT examinations performed in three hospitals during the period of two years, the author found 620 (12.6%) negative CT examinations. In 312 of the 620, the CT was requested because of 'abnormal shadow' on chest radiograph. When the same chest radiographs were re-evaluated by two radiologists, no abnormality was noted in 257 cases (82.4%). CT examinations were considered justified in only 55 cases (17.6%). There was a significant difference in the frequency of normal chest CT examinations between the university hospital and two other hospitals. The causes of false positive interpretation of chest radiographs were analyzed, and it was felt that fundamental knowledge necessary to interpret chest radiographs was lacking. The importance of close cooperation between clinicians and radiologists should be emphasized. (author)

  20. Hyperhomocysteinemia, methylenetetrahydrofolate reductase c.677C>T polymorphism and risk of cancer: cross-sectional and prospective studies and meta-analyses of 75,000 cases and 93,000 controls

    DEFF Research Database (Denmark)

    Zacho, Jeppe; Yazdanyar, Shiva; Bojesen, Stig E

    2011-01-01

    from 1.0. However, in meta-analyses odds ratio for MTHFR c.677C>T homozygotes versus noncarriers were 1.07 (95% CI: 1.01-1.12) for any cancer, 1.77 (1.17-2.68) for esophagus cancer, 1.40 (1.19-1.66) for gastric cancer and 0.85 (0.77-0.94) for colorectal cancer. Increased plasma homocysteine levels...... are not associated with an increased age-adjusted risk of any cancer. However, MTHFR c.677C>T homozygosity with lifelong hyperhomocysteinemia and hence hypomethylation associate with increased risk of esophagus and gastric cancer, and with decreased risk of colorectal cancer.......Global DNA hypomethylation associates with development of cancer. DNA hypomethylation also associates with hyperhomocysteinemia and MTHFR c.677C>T homozygosity, both of which may associate with increased risk of cancer. We tested the putative association of hyperhomocysteinemia with cancer...

  1. Polymorphisms -1082 G/A and -819 C/T in the interleukin-10 gene are not associated with gout susceptibility in the Chinese Han male population.

    Science.gov (United States)

    Liu, Shiguo; Zhang, Kun; Yin, Congcong; Han, Lin; Sun, Yuping; Ren, Wei; Chu, Nan; Li, Changgui

    2012-08-01

    Gout is caused by monosodium urate crystal-induced inflammation of the joints and periarticular tissues. Interleukin 10 (IL-10) is an important immunoregulatory cytokine, levels of which can be influenced by functional single-nucleotide polymorphisms in the promoter. To investigate the association of -1082 G/A and -819 C/T polymorphisms in the IL-10 promoter with gout susceptibility in the Chinese Han male population. A case-control study was performed in 302 patients and 284 controls. Genotyping of IL-10 -1082 G/A and -819 C/T polymorphisms was performed by DNA sequencing techniques. An association analysis was analyzed by the χ(2) test. No significant differences were found in -819T/C and -1082 A/G genotypic and allelic frequencies between gout cases and controls (for -819T/C, χ(2)=0.212, df=1, p=0.645 by genotype; χ(2)=0.079, df=1, p=0.779 by allele; for -1082 A/G, χ(2)=2.116, df=1, p=0.146 by genotype; χ(2)=1.854, df=1, p=0.173 by allele). IL-10 -1082 G/A and -819 C/T polymorphisms may not be associated with susceptibility to gout and thus do not play a major role in the development of gout in the Chinese Han male population.

  2. CT detection of hydronephrosis in resected colorectal cancer: a predictor of recurrent disease

    International Nuclear Information System (INIS)

    Brown, G.; Drury, A.E.; Cunningham, D.; Husband, J.E.S.

    2003-01-01

    AIM: To investigate the causes and significance of hydronephrosis in follow-up of colorectal cancer. METHODS AND MATERIALS: Case notes and serial computed tomography (CT) examinations were reviewed of 75 patients (250 CT examinations) after resection for colorectal cancer in whom hydronephrosis developed on follow-up. RESULTS: The most common cause of hydronephrosis was a focal plaque-like mass centred on the peritoneum, demonstrated in 37 cases (49%). Patients with R1 (microscopic residual tumour) or R2 (macroscopic residual tumour) disease developed hydronephrosis at a median time of 13 months (90% CI: 9-18 months) compared with 22 months (90% CI: 17-26 months) for those having (R0) curative resection. Patients with pT4 invasion of peritoneum or adjacent organs developed hydronephrosis at a median of 14 months (90% CI: 6-16 months) compared with a median of 22 months in patients with pT3 tumours (90% CI: 11-27 months). Of 26 patients without an obvious cause of hydronephrosis on initial CT examination, follow-up CT demonstrated a definite mass lesion in 50%. Median survival after the onset of hydronephrosis was 6 months (range 1-34 months) with a 1-year mortality of 62%. CONCLUSIONS: Hydronephrosis is an important early indicator of colorectal cancer recurrence, even in the absence of a mass. Brown, G. etal. (2003). Clinical Radiology58, 137-142

  3. CT detection of hydronephrosis in resected colorectal cancer: a predictor of recurrent disease

    Energy Technology Data Exchange (ETDEWEB)

    Brown, G.; Drury, A.E.; Cunningham, D.; Husband, J.E.S

    2003-02-01

    AIM: To investigate the causes and significance of hydronephrosis in follow-up of colorectal cancer. METHODS AND MATERIALS: Case notes and serial computed tomography (CT) examinations were reviewed of 75 patients (250 CT examinations) after resection for colorectal cancer in whom hydronephrosis developed on follow-up. RESULTS: The most common cause of hydronephrosis was a focal plaque-like mass centred on the peritoneum, demonstrated in 37 cases (49%). Patients with R1 (microscopic residual tumour) or R2 (macroscopic residual tumour) disease developed hydronephrosis at a median time of 13 months (90% CI: 9-18 months) compared with 22 months (90% CI: 17-26 months) for those having (R0) curative resection. Patients with pT4 invasion of peritoneum or adjacent organs developed hydronephrosis at a median of 14 months (90% CI: 6-16 months) compared with a median of 22 months in patients with pT3 tumours (90% CI: 11-27 months). Of 26 patients without an obvious cause of hydronephrosis on initial CT examination, follow-up CT demonstrated a definite mass lesion in 50%. Median survival after the onset of hydronephrosis was 6 months (range 1-34 months) with a 1-year mortality of 62%. CONCLUSIONS: Hydronephrosis is an important early indicator of colorectal cancer recurrence, even in the absence of a mass. Brown, G. etal. (2003). Clinical Radiology58, 137-142.

  4. SU-F-T-642: Sub Millimeter Accurate Setup of More Than Three Vertebrae in Spinal SBRT with 6D Couch

    International Nuclear Information System (INIS)

    Wang, X; Zhao, Z; Yang, J; Yang, J; McAleer, M; Brown, P; Li, J; Ghia, A

    2016-01-01

    Purpose: To assess the initial setup accuracy in treating more than 3 vertebral body levels in spinal SBRT using a 6D couch. Methods: We retrospectively analyzed last 20 spinal SBRT patients (4 cervical, 9 thoracic, 7 lumbar/sacrum) treated in our clinic. These patients in customized immobilization device were treated in 1 or 3 fractions. Initial setup used ExacTrac and Brainlab 6D couch to align target within 1 mm and 1 degree, following by a cone beam CT (CBCT) for verification. Our current standard practice allows treating a maximum of three continuous vertebrae. Here we assess the possibility to achieve sub millimeter setup accuracy for more than three vertebrae by examining the residual error in every slice of CBCT. The CBCT had a range of 17.5 cm, which covered 5 to 9 continuous vertebrae depending on the patient and target location. In the study, CBCT from the 1st fraction treatment was rigidly registered with the planning CT in Pinnacle. The residual setup error of a vertebra was determined by expanding the vertebra contour on the planning CT to be large enough to enclose the corresponding vertebra on CBCT. The margin of the expansion was considered as setup error. Results: Out of the 20 patients analyzed, initial setup accuracy can be achieved within 1 mm for a span of 5 or more vertebrae starting from T2 vertebra to inferior vertebra levels. 2 cervical and 2 upper thoracic patients showed the cervical spine was difficult to achieve sub millimeter accuracy for multi levels without a customized immobilization headrest. Conclusion: If the curvature of spinal columns can be reproduced in customized immobilization device during treatment as simulation, multiple continuous vertebrae can be setup within 1 mm with the use of a 6D couch.

  5. SU-F-T-642: Sub Millimeter Accurate Setup of More Than Three Vertebrae in Spinal SBRT with 6D Couch

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X; Zhao, Z; Yang, J; Yang, J; McAleer, M; Brown, P; Li, J; Ghia, A [MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To assess the initial setup accuracy in treating more than 3 vertebral body levels in spinal SBRT using a 6D couch. Methods: We retrospectively analyzed last 20 spinal SBRT patients (4 cervical, 9 thoracic, 7 lumbar/sacrum) treated in our clinic. These patients in customized immobilization device were treated in 1 or 3 fractions. Initial setup used ExacTrac and Brainlab 6D couch to align target within 1 mm and 1 degree, following by a cone beam CT (CBCT) for verification. Our current standard practice allows treating a maximum of three continuous vertebrae. Here we assess the possibility to achieve sub millimeter setup accuracy for more than three vertebrae by examining the residual error in every slice of CBCT. The CBCT had a range of 17.5 cm, which covered 5 to 9 continuous vertebrae depending on the patient and target location. In the study, CBCT from the 1st fraction treatment was rigidly registered with the planning CT in Pinnacle. The residual setup error of a vertebra was determined by expanding the vertebra contour on the planning CT to be large enough to enclose the corresponding vertebra on CBCT. The margin of the expansion was considered as setup error. Results: Out of the 20 patients analyzed, initial setup accuracy can be achieved within 1 mm for a span of 5 or more vertebrae starting from T2 vertebra to inferior vertebra levels. 2 cervical and 2 upper thoracic patients showed the cervical spine was difficult to achieve sub millimeter accuracy for multi levels without a customized immobilization headrest. Conclusion: If the curvature of spinal columns can be reproduced in customized immobilization device during treatment as simulation, multiple continuous vertebrae can be setup within 1 mm with the use of a 6D couch.

  6. 18F FDG Uptake of Human Testis on PET/CT: Correlation with Age, Sex Hormones, and Vasectomy

    International Nuclear Information System (INIS)

    Moon, Seung Hwan; Eo, Jae Sun; Lee, Jong Jin; Chung, June Key; Lee, Dong Soo; Lee, Myung Chul

    2011-01-01

    The purpose of this study was to evaluate glucose metabolism of normal human testis on 18F FDG PET/CT and to assess possible correlation among age, the serum levels of sex hormones, and vasectomy. 18F FDG PET/CT was performed in 66 normal healthy men (50.8±13.6 years, range 22-81), and mean standard uptake values (SUV) of 18F FDG in testis and adductor muscle were measured. Testis muscle SUV ratios (T/M ratios) were calculated. Serum levels of total testosterone, free testosterone, estradiol, and of sex hormone binding globulin (SHBG) were measured. We searched for correlations between T/M ratios and age and the serum concentrations of sex hormones. 18F FDG PET/CT was also performed in 32 vasectomized men (55.7±7.8 years, range 38-71) and 52 nonvasectomized men (55.4±11.6 years, range 37-72). Mean SUVs of testis and adductor muscle were measured, and T/M ratios were calculated. A significant age related decline was found in T/M ratio (r=-0.509, p 18F FDG uptake may have attributed to testicular function and testicular histology. Our findings may have important implications for the interpretation of testicular 18F FDG uptake in the normal adult population.

  7. Discrimination and anatomical mapping of PET-positive lesions: comparison of CT attenuation-corrected PET images with coregistered MR and CT images in the abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Felix P.; Crook, David W.; Mader, Caecilia E.; Appenzeller, Philippe; Schulthess, G.K. von; Schmid, Daniel T. [University Hospital Zurich, Department of Medical Radiology, Zurich (Switzerland)

    2013-01-15

    PET/MR has the potential to become a powerful tool in clinical oncological imaging. The purpose of this prospective study was to evaluate the performance of a single T1-weighted (T1w) fat-suppressed unenhanced MR pulse sequence of the abdomen in comparison with unenhanced low-dose CT images to characterize PET-positive lesions. A total of 100 oncological patients underwent sequential whole-body {sup 18}F-FDG PET with CT-based attenuation correction (AC), 40 mAs low-dose CT and two-point Dixon-based T1w 3D MRI of the abdomen in a trimodality PET/CT-MR system. PET-positive lesions were assessed by CT and MRI with regard to their anatomical location, conspicuity and additional relevant information for characterization. From among 66 patients with at least one PET-positive lesion, 147 lesions were evaluated. No significant difference between MRI and CT was found regarding anatomical lesion localization. The MR pulse sequence used performed significantly better than CT regarding conspicuity of liver lesions (p < 0.001, Wilcoxon signed ranks test), whereas no difference was noted for extrahepatic lesions. For overall lesion characterization, MRI was considered superior to CT in 40 % of lesions, equal to CT in 49 %, and inferior to CT in 11 %. Fast Dixon-based T1w MRI outperformed low-dose CT in terms of conspicuity and characterization of PET-positive liver lesions and performed similarly in extrahepatic tumour manifestations. Hence, under the assumption that the technical issue of MR AC for whole-body PET examinations is solved, in abdominal PET/MR imaging the replacement of low-dose CT by a single Dixon-based MR pulse sequence for anatomical lesion correlation appears to be valid and robust. (orig.)

  8. Discrimination and anatomical mapping of PET-positive lesions: comparison of CT attenuation-corrected PET images with coregistered MR and CT images in the abdomen

    International Nuclear Information System (INIS)

    Kuhn, Felix P.; Crook, David W.; Mader, Caecilia E.; Appenzeller, Philippe; Schulthess, G.K. von; Schmid, Daniel T.

    2013-01-01

    PET/MR has the potential to become a powerful tool in clinical oncological imaging. The purpose of this prospective study was to evaluate the performance of a single T1-weighted (T1w) fat-suppressed unenhanced MR pulse sequence of the abdomen in comparison with unenhanced low-dose CT images to characterize PET-positive lesions. A total of 100 oncological patients underwent sequential whole-body 18 F-FDG PET with CT-based attenuation correction (AC), 40 mAs low-dose CT and two-point Dixon-based T1w 3D MRI of the abdomen in a trimodality PET/CT-MR system. PET-positive lesions were assessed by CT and MRI with regard to their anatomical location, conspicuity and additional relevant information for characterization. From among 66 patients with at least one PET-positive lesion, 147 lesions were evaluated. No significant difference between MRI and CT was found regarding anatomical lesion localization. The MR pulse sequence used performed significantly better than CT regarding conspicuity of liver lesions (p < 0.001, Wilcoxon signed ranks test), whereas no difference was noted for extrahepatic lesions. For overall lesion characterization, MRI was considered superior to CT in 40 % of lesions, equal to CT in 49 %, and inferior to CT in 11 %. Fast Dixon-based T1w MRI outperformed low-dose CT in terms of conspicuity and characterization of PET-positive liver lesions and performed similarly in extrahepatic tumour manifestations. Hence, under the assumption that the technical issue of MR AC for whole-body PET examinations is solved, in abdominal PET/MR imaging the replacement of low-dose CT by a single Dixon-based MR pulse sequence for anatomical lesion correlation appears to be valid and robust. (orig.)

  9. SU-E-T-504: Usefulness of CT-MR Fusion in Radiotherapy Planning for Prostate Cancer Patient with Bilateral Hip Replacements

    Energy Technology Data Exchange (ETDEWEB)

    He, R.; Giri, Shankar [University of Mississippi Med. Center, Jackson, MS (United States); VA Medical Center at Jackson, Mississippi (United States); Kumar, P. [VA Medical Center at Jackson, Mississippi (United States); Hu, Y.; Suggs, J.; Yang, C. [University of Mississippi Med. Center, Jackson, MS (United States)

    2014-06-01

    Purpose: Target localization of prostate for Intensity Modulated Radiation Therapy (IMRT) in patients with bilateral hip replacements is difficult due to artifacts in Computed Tomography (CT) images generated from the prostheses high Z materials. In this study, Magnetic Resonance (MR) images fused with CT images are tested as a solution. Methods: CT images of 2.5 mm slice thickness were acquired on a GE Lightspeed scanner with a flat-topped couch for a prostate cancer patient with bilateral hip replacements. T2 weighted images of 5 mm separation were acquired on a MR Scanner. After the MR-CT registration on a radiotherapy treatment planning system (Eclipse, Varian), the target volumes were defined by the radiation oncologists on MR images and then transferred to CT images for planning and dose calculation. The CT Hounsfield Units (HU) was reassigned to zero (as water) for artifacts. The Varian flat panel treatment couch was modeled for dose calculation accuracy with heterogeneity correction. A Volume Matrix Arc Therapy (VMAT) and a seven-field IMRT plans were generated, each avoiding any beam transversing the prostheses; the two plans were compared. The superior VMAT plan was used for treating the patient. In-vivo dosimetry was performed using MOSFET (Best Canada) placed in a surgical tube inserted into the patient rectum during therapy. The measured dose was compared with planned dose for MOSFET location. Results: The registration of MR-CT images and the agreement of target volumes were confirmed by three physicians. VMAT plan was deemed superior to IMRT based on dose to critical nearby structures and overall conformality of target dosing. In-vivo measured dose compared with calculated dose was -4.5% which was likely due to attenuation of the surgical tube surrounding MOSFET. Conclusion: When artifacts are present on planning CT due to bilateral hip prostheses, MR-CT image fusion is a feasible solution for target delineation.

  10. SU-E-T-504: Usefulness of CT-MR Fusion in Radiotherapy Planning for Prostate Cancer Patient with Bilateral Hip Replacements

    International Nuclear Information System (INIS)

    He, R.; Giri, Shankar; Kumar, P.; Hu, Y.; Suggs, J.; Yang, C.

    2014-01-01

    Purpose: Target localization of prostate for Intensity Modulated Radiation Therapy (IMRT) in patients with bilateral hip replacements is difficult due to artifacts in Computed Tomography (CT) images generated from the prostheses high Z materials. In this study, Magnetic Resonance (MR) images fused with CT images are tested as a solution. Methods: CT images of 2.5 mm slice thickness were acquired on a GE Lightspeed scanner with a flat-topped couch for a prostate cancer patient with bilateral hip replacements. T2 weighted images of 5 mm separation were acquired on a MR Scanner. After the MR-CT registration on a radiotherapy treatment planning system (Eclipse, Varian), the target volumes were defined by the radiation oncologists on MR images and then transferred to CT images for planning and dose calculation. The CT Hounsfield Units (HU) was reassigned to zero (as water) for artifacts. The Varian flat panel treatment couch was modeled for dose calculation accuracy with heterogeneity correction. A Volume Matrix Arc Therapy (VMAT) and a seven-field IMRT plans were generated, each avoiding any beam transversing the prostheses; the two plans were compared. The superior VMAT plan was used for treating the patient. In-vivo dosimetry was performed using MOSFET (Best Canada) placed in a surgical tube inserted into the patient rectum during therapy. The measured dose was compared with planned dose for MOSFET location. Results: The registration of MR-CT images and the agreement of target volumes were confirmed by three physicians. VMAT plan was deemed superior to IMRT based on dose to critical nearby structures and overall conformality of target dosing. In-vivo measured dose compared with calculated dose was -4.5% which was likely due to attenuation of the surgical tube surrounding MOSFET. Conclusion: When artifacts are present on planning CT due to bilateral hip prostheses, MR-CT image fusion is a feasible solution for target delineation

  11. 3D-CT implanted interstitial brachytherapy for T2b nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Ren, Yu-Feng; Gao, Yuan-Hong; Cao, Xin-Ping; Ye, Wei-Jun; Teh, Bin S

    2010-01-01

    To compare the results of external beam radiotherapy in combination with 3D- computed tomography (CT)-implanted interstitial high dose rate brachytherapy (ERT/3D-HDR-BT) versus conventional external beam radiotherapy (ERT) for the treatment of stage T2b nasopharyngeal carcinoma (NPC). Forty NPC patients diagnosed with stage T2b NPC were treated with ERT/3D-HDR-BT under local anesthesia. These patients received a mean dose of 60 Gy, followed by 12-20 Gy administered by 3D-HDR-BT. Another 101 patients diagnosed with non-metastatic T2b NPC received a mean dose of 68 Gy by ERT alone during the same period. Patients treated with ERT/3D-HDR-BT versus ERT alone exhibited an improvement in their 5-y local failure-free survival rate (97.5% vs. 80.2%, P = 0.012) and disease-free survival rate (92.5% vs. 73.3%, P = 0.014). Using multivariate analysis, administration of 3D-HDR-BT was found to be favorable for local control (P = 0.046) and was statistically significant for disease-free survival (P = 0.021). The incidence rate of acute and chronic complications between the two groups was also compared. It is possible that the treatment modality enhances local control due to improved conformal dose distributions and the escalated radiation dose applied

  12. Quantitative CT scans of lung parenchymal pathology in premature infants ages 0-6 years.

    Science.gov (United States)

    Spielberg, David R; Walkup, Laura L; Stein, Jill M; Crotty, Eric J; Rattan, Mantosh S; Hossain, Md Monir; Brody, Alan S; Woods, Jason C

    2018-03-01

    Bronchopulmonary dysplasia (BPD) is a common, heterogeneous disease in premature infants. We hypothesized that quantitative CT techniques could assess lung parenchymal heterogeneity in BPD patients across a broad age range and demonstrate how pathologies change over time. A cross-sectional, retrospective study of children age 0-6 years with non-contrast chest CT scans was conducted. BPD subjects met NICHD/NHLBI diagnostic criteria for BPD and were excluded for congenital lung/airway abnormalities or other known/suspected pulmonary diagnoses; control subjects were not premature and had normal CT scan findings. Radiologic opacities, lucencies, and spatial heterogeneity were quantified via: 1) thresholding using CT-attenuation (HU); 2) manual segmentation; and 3) Ochiai reader-scoring system. Clinical outcomes included BPD severity by NICHD/NHLBI criteria, respiratory support at NICU discharge, wheezing, and respiratory exacerbations. Heterogeneity (standard deviation) of lung attenuation in BPD was significantly greater than in controls (difference 36.4 HU [26.1-46.7 HU], P < 0.001); the difference between the groups decreased 0.58 HU per month of age (0.08-1.07 HU per month, P = 0.02). BPD patients had greater amounts of opacities and lucencies than controls except with automated quantification of lucencies. Cross-sectionally, lucencies per Ochiai score and opacities per manual segmentation decreased with time. No approach measured a statistically significant relationship to BPD clinical severity. Opacities, lucencies, and overall heterogeneity of lungs via quantitative CT can distinguish BPD patients from healthy controls, and these abnormalities decrease with age across BPD patients. Defining BPD severity by clinical outcomes such as respiratory support at several time points (vs a single time point, per current guidelines) may be meaningful. © 2017 Wiley Periodicals, Inc.

  13. The crystal structure and small-angle X-ray analysis of CsdL/TcdA reveal a new tRNA binding motif in the MoeB/E1 superfamily.

    Directory of Open Access Journals (Sweden)

    Miguel López-Estepa

    Full Text Available Cyclic N6-threonylcarbamoyladenosine ('cyclic t6A', ct(6A is a non-thiolated hypermodification found in transfer RNAs (tRNAs in bacteria, protists, fungi and plants. In bacteria and yeast cells ct(6A has been shown to enhance translation fidelity and efficiency of ANN codons by improving the faithful discrimination of aminoacylated tRNAs by the ribosome. To further the understanding of ct(6A biology we have determined the high-resolution crystal structures of CsdL/TcdA in complex with AMP and ATP, an E1-like activating enzyme from Escherichia coli, which catalyzes the ATP-dependent dehydration of t6A to form ct(6A. CsdL/TcdA is a dimer whose structural integrity and dimer interface depend critically on strongly bound K+ and Na+ cations. By using biochemical assays and small-angle X-ray scattering we show that CsdL/TcdA can associate with tRNA with a 1:1 stoichiometry and with the proper position and orientation for the cyclization of t6A. Furthermore, we show by nuclear magnetic resonance that CsdL/TcdA engages in transient interactions with CsdA and CsdE, which, in the latter case, involve catalytically important residues. These short-lived interactions may underpin the precise channeling of sulfur atoms from cysteine to CsdL/TcdA as previously characterized. In summary, the combination of structural, biophysical and biochemical methods applied to CsdL/TcdA has afforded a more thorough understanding of how the structure of this E1-like enzyme has been fine tuned to accomplish ct(6A synthesis on tRNAs while providing support for the notion that CsdA and CsdE are able to functionally interact with CsdL/TcdA.

  14. Statistical analyses of fracture toughness results for two irradiated high-copper welds

    International Nuclear Information System (INIS)

    Nanstad, R.K.; McCabe, D.E.; Haggag, F.M.; Bowman, K.O.; Downing, D.J.

    1990-01-01

    The objectives of the Heavy-Section Steel Irradiation Program Fifth Irradiation Series were to determine the effects of neutron irradiation on the transition temperature shift and the shape of the K Ic curve described in Sect. 6 of the ASME Boiler and Pressure Vessel Code. Two submerged-arc welds with copper contents of 0.23 and 0.31% were commercially fabricated in 215-mm-thick plates. Charpy V-notch (CVN) impact, tensile, drop-weight, and compact specimens up to 203.2 mm thick [1T, 2T, 4T, 6T, and 8T C(T)] were tested to provide a large data base for unirradiated material. Similar specimens with compacts up to 4T were irradiated at about 288 degrees C to a mean fluence of about 1.5 x 10 19 neutrons/cm 2 (>1 MeV) in the Oak Ridge Research Reactor. Both linear-elastic and elastic-plastic fracture mechanics methods were used to analyze all cleavage fracture results and local cleavage instabilities (pop-ins). Evaluation of the results showed that the cleavage fracture toughness values determined at initial pop-ins fall within the same scatter band as the values from failed specimens; thus, they were included in the data base for analysis (all data are designated K Jc )

  15. The role of IL6 and ESR1 gene polymorphisms as immunological factors of pregnancy maintenance

    Directory of Open Access Journals (Sweden)

    Kucherenko A. M.

    2013-09-01

    Full Text Available Aim. The study is aimed at the evaluation of the association of IL6 gene -174G/C polymorphism and ESR1 gene -397C/T polymorphism with recurrent pregnancy loss (RPL pathogenesis and at the investigation of the ESR1 gene -397C/T variant regulatory significance for the IL6 gene function. Methods. A case group of 75 women with RPL history and a control group of 106 unrelated healthy women, who have given birth to at least one child conceived in natural way, were genotyped by a PCR based restriction fragment length polymorphism assay. Results. There was no significant difference in IL6 -174G/C or ESR1 -397C/T genotype and allele frequencies between the case and control groups. Combined genotype distribution analysis showed significantly (p < 0.05 lower frequency of individuals homozygous for both IL6 -174G and ESR1 -397C alleles in case group (0.026 comparing to control (0.094. Conclusions. Genotype comprising IL6 -174G and ESR1 -397C alleles in homozygous state may be considered as a genetic marker of successful pregnancy maintenance during gestation early stages.

  16. Improved correlation between CT emphysema quantification and pulmonary function test by density correction of volumetric CT data based on air and aortic density

    International Nuclear Information System (INIS)

    Kim, Song Soo; Seo, Joon Beom; Kim, Namkug; Chae, Eun Jin; Lee, Young Kyung; Oh, Yeon Mok; Lee, Sang Do

    2014-01-01

    Objectives: To determine the improvement of emphysema quantification with density correction and to determine the optimal site to use for air density correction on volumetric computed tomography (CT). Methods: Seventy-eight CT scans of COPD patients (GOLD II–IV, smoking history 39.2 ± 25.3 pack-years) were obtained from several single-vendor 16-MDCT scanners. After density measurement of aorta, tracheal- and external air, volumetric CT density correction was conducted (two reference values: air, −1000 HU/blood, +50 HU). Using in-house software, emphysema index (EI) and mean lung density (MLD) were calculated. Differences in air densities, MLD and EI prior to and after density correction were evaluated (paired t-test). Correlation between those parameters and FEV 1 and FEV 1 /FVC were compared (age- and sex adjusted partial correlation analysis). Results: Measured densities (HU) of tracheal- and external air differed significantly (−990 ± 14, −1016 ± 9, P < 0.001). MLD and EI on original CT data, after density correction using tracheal- and external air also differed significantly (MLD: −874.9 ± 27.6 vs. −882.3 ± 24.9 vs. −860.5 ± 26.6; EI: 16.8 ± 13.4 vs. 21.1 ± 14.5 vs. 9.7 ± 10.5, respectively, P < 0.001). The correlation coefficients between CT quantification indices and FEV 1 , and FEV 1 /FVC increased after density correction. The tracheal air correction showed better results than the external air correction. Conclusion: Density correction of volumetric CT data can improve correlations of emphysema quantification and PFT

  17. SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, W; Xue, M; Patel, K; Regine, W; Wang, J; D’Souza, W; Lu, W [University of Maryland School of Medicine, Baltimore, MD (United States); Kang, M [University of Maryland School of Medicine, Baltimore, MD (United States); Yeungnam University Medical Center, Daegu, Daegu (Korea, Republic of); Klahr, P [Philips Healthcare, Highland Heights, OH (United States)

    2015-06-15

    Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.

  18. HSD17B12 gene rs11037575 C>T polymorphism confers neuroblastoma susceptibility in a Southern Chinese population

    Directory of Open Access Journals (Sweden)

    Zhang ZR

    2017-04-01

    Full Text Available Zhuorong Zhang,1,2 Yan Zou,2 Jinhong Zhu,3 Ruizhong Zhang,2 Tianyou Yang,2 Fenghua Wang,2 Huimin Xia,1,2 Jing He,2 Zhichun Feng1,4–6 1Southern Medical University, Guangzhou, Guangdong, 2Department of Pediatric Surgery, Guangzhou Institute of Pediatrics, Guangzhou Women and Children’s Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, 3Molecular Epidemiology Laboratory, Department of Laboratory Medicine, Harbin Medical University Cancer Hospital, Harbin, Heilongjiang, 4Division of Neonatology, Affiliated BaYi Children’s Hospital, Clinical Medical College in PLA Army General Hospital, Southern Medical University, 5National Engineering Laboratory for Birth Defects Prevention and Control of Key Technology, 6Beijing Key Laboratory of Pediatric Organ Failure, Beijing, People’s Republic of China Abstract: A previous genome-wide association study (GWAS identified four genetic polymorphisms (rs1027702 near DUSP12, rs10055201 in IL31RA, rs2619046 in DDX4, and rs11037575 in HSD17B12 gene that were associated with neuroblastoma susceptibility, especially for low-risk subjects. The aim of this study was to examine the association between these four polymorphisms and neuroblastoma susceptibility in a Southern Chinese population composed of 256 cases and 531 controls. Overall, among all the polymorphisms, single-locus analysis only revealed significant association between the HSD17B12 rs11037575 C>T polymorphism and neuroblastoma susceptibility (CT vs CC: adjusted odds ratio [OR] =0.71, 95% confidence interval [CI] =0.51–0.97, P=0.030. Moreover, stratified analysis indicated that the rs11037575 T allele was associated with decreased neuroblastoma risk among the children aged 0–18 months (adjusted OR =0.60, 95% CI =0.37–0.97, P=0.036; regarding the tumor site, this polymorphism protected against tumor in the mediastinum (adjusted OR =0.59, 95% CI =0.37–0.94, P=0.025. When risk genotypes were combined, we found that girls with

  19. CT and MRI diagnosis of intracranial chondroma

    International Nuclear Information System (INIS)

    Liu Xuejun; Sui Qinglan

    2006-01-01

    Objective: To summarize and study the features of intracranial chondroma on CT and MRI imaging. Methods: CT and MRI findings of ten cases of intracranial chondroma proved by surgery and pathology from 1994. 1 to 2004.9 were retrospectively analyzed. Results: Among 10 cases, 4 cases were located at the skull base, 4 cases at convexity, 1 case at the region of falx cerebri, and 1 case within the brain parenchyma. CT scans showed obvious calcification and clear border of the tumors in 10 cases, mixed attenuation in 9 eases, and adjacent bone invasion in 5 cases. 4 cases of MRI scans showed hypointense signal on T 1 and T 2 -weighted images in calcified element of the tumor, intermediate to hypointense signal intensity on T 1 -weighted image, and hyperintense signal intensity on T 2 -weighted image in parenchyma of the tumor. 4 cases of CT scans showed slightly enhancement. Conclusion: Intracranial chondroma are often originated from synchondrosis of the skull base, convexity of brain and region of falx cerebri. Obvious calcification may be seen in most cases. Slightly enhancement and marked delayed contrast enhancement were characteristic. The accurate diagnosis still depends on pathology. (authors)

  20. T6 and T78 tempers of AA6065 alloy: a quantitative TEM study

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, M.; Warner, T. [Compagnie de Produits Chimiques et Electrometallurgiques Pechiney, Centre de Recherches de Voreppe, 38 (France)

    2000-07-01

    Quantitative transmission electron microscopy is used to characterize the microstructure of an industrial Al-Mg-Si-Cu alloy (AA6056) in a state (T78 temper) desensitized to intergranular corrosion in comparison with the peak aged state (T6 temper). Analysis of dark-field images and of zero-loss filtered selected-area-diffraction patterns, along with EDX spectroscopy, indicates an advanced precipitation of the quaternary phase containing Si and Cu in the T78-tempered alloy compared to the T6 one. This supports the current theory of the desensitization of AA6056 alloy. However, the application of EDX analysis to provide direct evidence of the chemical composition variation in the solid solution across the grain boundary appears less satisfactory. (orig.)

  1. Thin-section CT of Cushing's disease

    International Nuclear Information System (INIS)

    Takahashi, Tatsuo; Kuwayama, Akio; Katoh, Tetsuo; Ichihara, Kaoru; Kageyama, Naoki; Nakamura, Koji.

    1983-01-01

    Using 1.5 mm contiguous sections with a GE CT/T 8800 scanner, we investigated the sellar regions of 22 cases of Cushing's diseases which had been diagnosed endocrinologically. Each sellar turcica was normal in size, and in only 5 cases were there significant findings on 2 mm-thick sellar-floor polytomography. Nine tumors appeared as regions of a hypodense area, and three tumors were diagnosed by indirect signs, for example, stalk deviation and diaphragmatic plane asymmetry. The other 10 cases, especially those previously operated on or irradiated, were diagnosed as falsely positive or negative. Because it is best of the microadenomas appear hypodense within the strongly contrast-enhanced anterior pituitary glands, it is better for scans to be obtained immediately after rapid intravenous contrast infusion. Hypodense areas of microadenomas are best demonstrated on direct coronal scans or reversed scans of 1.5 mm-thickness thin-slice sections. By these methods, microadenomas, if they are over 5-6 mm in diameter, can appear as hypodense. Sellar floor findings by means of thin-section CT were more sensitive than those of polytomography and had more advantages in local diagnosis. If the tumor were over 4 mm in diameter, local changes in the sellar floor could be demonstrated by thin-section CT, but by polytomography no changes in the sellar floor could be demonstrated until the tumor size reached 6 mm. (author)

  2. DETECTING PRESENCE OF C/T POLYMORPHISM AT POSITION 34 SECOND INTRON OF THE MYOSTATIN GENE IN RABBITS

    Directory of Open Access Journals (Sweden)

    Agnieszka MARKOWSKA

    2011-01-01

    Full Text Available Myostatin gene is a negative regulator of skeletal muscles growth. It is responsible for normal development of skeletal muscles. The objective of the research was to detect variation of C/T at position 34 of the second intron of the MNST gene in rabbits. The research included 114 rabbits: 54 of them Polish Rabbits, and 60 of them White Flemish Giants, examined by means of the PCR-RFLP method using AluI restriction enzyme. We found allele C with a frequency of 0.6184 of the examined rabbit population, and allele T with a frequency of 0.3816 of the examined rabbits.

  3. O6-ethylguanine carcinogenic lesions in DNA: An NMR study of O6etG·T pairing in dodecanucloetide duplexes

    International Nuclear Information System (INIS)

    Kalnik, M.W.; Li, B.F.L.; Swann, P.F.; Patel, D.J.

    1989-01-01

    High-resolution two-dimensional NMR studies are reported on the self-complementary d-(C1-G2-C3-O 6 etG4-A5-G6-C7-T8-T9-G10-C11-G12) duplex (designated O 6 etG·T 12-mer) containing two symmetrically related O 6 etG·T lesion sites located four base pairs in from either end of the duplex. Parallel studies were undertaken on a related sequence containing O 6 meG·T lesion sites (designated O 6 meG·T 12-mer) in order to evaluate the influence of the size of the alkyl substituent on the structure of the duplex and were undertaken on a related sequence containing G·T mismatch sites (designated G·T 12-mer duplex), which served as the control duplex. The exchangeable and nonexchangeable proton and the phosphorus nuclei have been assigned from an analysis of two-dimensional nuclear Overhauser enhancement (NOE) and correlated spectra of the O 6 etG·T 12-mer, O 6 meG·T 12-mer, and G·T 12-mer duplexes in H 2 O and D 2 O solutions. The distance connectivities observed in the NOESY spectra of the O 6 alkG·T 12-mer duplexes establish that the helix is right-handed and all of the bases adopt an anti conformation of the glycosidic torsion angle including the O 6 alkG4 and T9 bases at the lesion site. These observations establish that the O 6 alkG4 and T9 residues are stacked into the duplex and that the O 6 CH 3 and O 6 CH 2 CH 3 groups of O 6 alkG4 adopt a syn orientation with respect to the N 1 of the alkylated guanine. Since the O 6 -alkyl group adopts a syn orientation, the separation between the O 6 of O 6 alkG4 and the O 4 of T9 in the major groove is increased, preventing the formation of a short hydrogen bond between the N 1 ring nitrogen of O 6 alkG4 and the imino proton of T9

  4. A study on density, porosity and grain size of unirradiated ROX fuels and simulated ROX fuels

    International Nuclear Information System (INIS)

    Yanagisawa, Kazuaki; Shirasu, Noriko; Ohmichi, Toshihiko

    1999-05-01

    The unirradiated ROX fuels made of (1) 23wt%PuO 2 -17wt%SZR-56wt%Al 2 O 3 -4wt%MgO (ROX-SZR) and (2) 20wt%PuO 2 -29wt%ThO 2 -48wt%Al 2 O 3 -3wt%MgO (ROX-ThO 2 ) were fabricated by JAERI. Additionally, 9 simulated ROX fuels (used UO 2 instead of PuO 2 ) were fabricated by NFI. Densities, porosity and grain sizes of those were studied. Obtained results are: (1) ROX fuels: The estimated theoretical density (TD) was 5.6g/cc for the ROX-SZR and 6.2g/cc for the ROX-ThO 2 . Those were about half of that in UO 2 (10.96g/cc). As-fabricated density determined was 4.6g/cc (82%TD) for the former and 5.2g/cc (83%TD) for the latter. The %TD of those was low than that of UO 2 (95%TD). One of main reason is that the ROX fuels were sintered at temperature of 1,400degC while UO 2 was sintered at temperature of 1,700degC. The average pore diameter was about 3 μm and the porosity was 17-18%, implying that the ROX fuels were resulted in containing a lot of small pores 2 . As-fabricated density determined in the present study was about 4.5-5.5g/cc. The %TD of the simulated ROX fuels ranged about 94-98%TD. They were in the same as that of UO 2 because as high sintering temperature of 1,750degC as UO 2 . The average pore diameter was about 4-8 μm and the porosity was <6%. Grain size was revealed to be about 1-4 μm. (author)

  5. Clinical values of CT and dynamic CT in brain infarction

    International Nuclear Information System (INIS)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul

    1985-01-01

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre-and postcontrast CT

  6. Clinical values of CT and dynamic CT in brain infarction

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University College of Medicine, Jeonju (Korea, Republic of)

    1985-04-15

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre

  7. CT and MRI of haemorrhage into intracranial neuromas

    Energy Technology Data Exchange (ETDEWEB)

    Asari, S. (Dept. of Neurological Surgery, Okayama Univ. Medical School, Okayama City (Japan)); Katayama, S. (Dept. of Neurological Surgery, Okayama Univ. Medical School, Okayama City (Japan)); Itoh, T. (Dept. of Neurological Surgery, Okayama Univ. Medical School, Okayama City (Japan)); Tsuchida, S. (Dept. of Neurological Surgery, Okayama Univ. Medical School, Okayama City (Japan)); Ohmoto, T. (Dept. of Neurological Surgery, Okayama Univ. Medical School, Okayama City (Japan))

    1993-04-01

    Six patients with haemorrhage into intracranial neuromas were studied by computed tomography (CT) and magnetic resonance imaging (MRI) at 0.5 T with spin-echo pulse sequences. The nature of the tumour and the presence of a haematoma were confirmed by surgery and microscopic examination in all cases. Four neuromas arose from the acoustic nerves and two from the trigeminal. Four of the six patients suffered from sudden onset or rapid worsening of symptoms including headache, vertigo and/or hemifacial motor and sensory disturbances. CT in the acute stage revealed a hyperdense area or a fluid-fluid level (FFL). The hyperdense area disappeared on CT repeated in the chronic stage. On MRI in subacute and chronic stages the haemorrhage showed hyperintensity on both T1 and T2 weighting in five cases examined between 16 and 46 days after the onset, and isointensity on T1 weighting and an FFL on T2 weighting in one case examined 12 days after the onset of symptoms. A well-defined low intensity rim indicating prior haemorrhage was observed on T2-weighted images in three cases. MRI was more effectie than CT in detecting haemorrhage into the tumours and in staging it. (orig.)

  8. In vitro differentiation of renal stone composition using dual-source, dual-energy CT

    International Nuclear Information System (INIS)

    Zhou Changsheng; Zhang Longjiang; Xu Feng; Qi Li; Zhao Yan'e; Zheng Ling; Huang Wei; Liu Youhuang; Lu Guangming

    2012-01-01

    Objective: To evaluate the ability of dual-source. dual-energy CT in differentiating uric acid stones from non-uric acid stones with infrared spectroscopy as reference standard. Materials and Methods: Urinary calculus from 308 patients were scanned in first generation dual-source CT with dual-energy mode between July 2011 and June 2012. Renal Stone application was used to analyze their composition. The uric acid stones color were coded red and non-uric acid stones were blue. CT values were measured in 60 selective urinary calculus including 30 uric acid stones and 30 non-uric acid stones. The accuracy of dual energy CT to differentiate uric acid and no-uric acid stones was calculated. Results: Of 308 patients, 60 patients had uric acid stones and 248 non-uric acid stones. No difference was found for uric acid stone at 80 kV and 140 kV (375.8±69.2 HU vs. 374.1±69.4 HU; t=-0.217, P=0.830), while CT values of non-uric acid stones were higher at 80 kV than those at 140 kV (1455.1±312.4 HU vs. 1039.6±194.4 HU; t=-12.16. P<0.001). CT values of non-uric acid stones at 80 kV, 140 kV, and average weighted images (1455.1±312.4 HU, 1 039.6±194.4 HU, and 882.0±176.4 HU, respectively) were higher than those of uric acid stones (375.8±69.2 HU, 374.1±69.4 HU, and 366.3±80.1 HU, respectively; P<0.001). With infrared spectrum findings as reference standard, the accuracy of dual energy CT in differentiating uric acid stones from non-uric acid stones was 100%. Conclusions: Dual-source, dual-energy CT can accurately differentiate uric acid stones from non-uric acid stones, and plays an important role in treatment planning of renal stones. (authors)

  9. Performance Evaluation of the T6 Ion Engine

    Science.gov (United States)

    Snyder, John Steven; Goebel, Dan M.; Hofer, Richard R.; Polk, James E.; Wallace, Neil C.; Simpson, Huw

    2010-01-01

    The T6 ion engine is a 22-cm diameter, 4.5-kW Kaufman-type ion thruster produced by QinetiQ, Ltd., and is baselined for the European Space Agency BepiColombo mission to Mercury and is being qualified under ESA sponsorship for the extended range AlphaBus communications satellite platform. The heritage of the T6 includes the T5 ion thruster now successfully operating on the ESA GOCE spacecraft. As a part of the T6 development program, an engineering model thruster was subjected to a suite of performance tests and plume diagnostics at the Jet Propulsion Laboratory. The engine was mounted on a thrust stand and operated over its nominal throttle range of 2.5 to 4.5 kW. In addition to the typical electrical and flow measurements, an E x B mass analyzer, scanning Faraday probe, thrust vector probe, and several near-field probes were utilized. Thrust, beam divergence, double ion content, and thrust vector movement were all measured at four separate throttle points. The engine performance agreed well with published data on this thruster. At full power the T6 produced 143 mN of thrust at a specific impulse of 4120 seconds and an efficiency of 64%; optimization of the neutralizer for lower flow rates increased the specific impulse to 4300 seconds and the efficiency to nearly 66%. Measured beam divergence was less than, and double ion content was greater than, the ring-cusp-design NSTAR thruster that has flown on NASA missions. The measured thrust vector offset depended slightly on throttle level and was found to increase with time as the thruster approached thermal equilibrium.

  10. IL18 and IL18R1 polymorphisms, lung CT and fibrosis: a longitudinal study in coal miners

    Energy Technology Data Exchange (ETDEWEB)

    Nadif, R.; Mintz, M.; Marzec, J.; Jedlicka, A.; Kauffmann, F.; Kleeberger, S.R. [INSERM, U780, Villejuif (France)

    2006-12-15

    It has been suggested that interleukin (IL)-18 plays a role in the development of inflammatory and fibrosing lung diseases. Associations of polymorphisms in the genes coding for IL-18 (108 /G-656T, C-607A, G-137C, T113G, C127T) and its receptor (IL8R1/C-69T) with coal workers' pneumoconiosis (CWP) were studied in 200 miners who were examined in 1990, 1994 and 1999. Coal-dust exposure was assessed according to job history and ambient measures. The main health outcome was lung computed tomography (CT) score in 1990. Internal coherence was assessed by studying CT score in 1994, 4-yr change in CT score and CWP incidence and prevalence. CT score in 1990 was a good predictor of radiographic grade in 1999 and, therefore, an appropriate subclinical quantitative trait. The IL18 -137C allele was associated with lower CT score in 1990 and 1994 (11.24 versus 1.69 and 1.57 versus 2.46, respectively), slower progression of CT score between 1990 and 1994 and lower pneumoconiosis prevalence in 1999 relative to the G allele (0.33 versus 0.77 and 8.2 versus 19.6%, respectively). Smoking- or dust-adjustment, and stratification on IL18R1 genotype and adjustment for haplotype effects did not change the conclusions. In conclusion, the results of the present study suggest a role for IL18 in reducing the development of this fibrosing lung disease.

  11. Topographic diagnosis of parathyroid tumor by CT scan

    International Nuclear Information System (INIS)

    Fukunaga, Masao; Harioka, Toshio; Morita, Rikuji

    1981-01-01

    In order to detect the hyperfunctioning parathyroid gland(s), CT scan over the neck was performed in patients with parathyroid disorders, including 10 primary hyperparathyroidism (6 bone type, 3 stone type and 1 chemical type), 8 chronic renal failure on hemodialysis with renal osteodystrophy and 2 multiple endocrine adenomatosis (MEA) type I. We used a whole-body scanner (CT/T, GE). The slice thickness was 5 mm. All patients were scanned from the sternal notch upward to the larynx, and were enhanced by the administration of 30% DIP Conray for 15 min. The results of the topographic diagnosis were compared with the surgical findings. Precise preoperative localization was accomplished in 9/10 adenomas in primary hyperparathyroidism, 27/32 hyperplasias in secondary hyperparathyroidism, and 2/4 hyperplasias in MEA type I. The smallest lesion weighed 0.2 g. It was shown that CT scan over the neck was a noninvasive and simple method to define the localization of hyperfunctionig parathyroid gland(s). (author)

  12. Reactor Materials Program electrochemical potential measurements by ORNL with unirradiated and irradiated stainless steel specimens

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, E.W.; Caskey, G.R. Jr.

    1993-07-01

    Effect of irradiation of stainless steel on electrochemical potential (ECP) was investigated by measurements in dilute HNO{sub 3} and H{sub 2}O{sub 2} solutions, conditions simulating reactor moderator. The electrodes were made from unirradiated/irradiated, unsensitized/sensitized specimens from R-reactor piping. Results were inconclusive because of budgetary restrictions. The dose rate may have been too small to produce a significant radiolytic effect. Neither the earlier CERT corrosion susceptibility tests nor the present ECP measurements showed a pronounced effect of irradiation on susceptibility of the stainless steel to IGSCC; this is confirmed by the absence in the stainless steel of the SRS reactor tanks (except for the C Reactor tank knuckle area).

  13. Reactor Materials Program electrochemical potential measurements by ORNL with unirradiated and irradiated stainless steel specimens

    International Nuclear Information System (INIS)

    Baumann, E.W.; Caskey, G.R. Jr.

    1993-07-01

    Effect of irradiation of stainless steel on electrochemical potential (ECP) was investigated by measurements in dilute HNO 3 and H 2 O 2 solutions, conditions simulating reactor moderator. The electrodes were made from unirradiated/irradiated, unsensitized/sensitized specimens from R-reactor piping. Results were inconclusive because of budgetary restrictions. The dose rate may have been too small to produce a significant radiolytic effect. Neither the earlier CERT corrosion susceptibility tests nor the present ECP measurements showed a pronounced effect of irradiation on susceptibility of the stainless steel to IGSCC; this is confirmed by the absence in the stainless steel of the SRS reactor tanks (except for the C Reactor tank knuckle area)

  14. c-T phase diagram and Landau free energies of (AgAu)55 nanoalloy via neural-network molecular dynamic simulations.

    Science.gov (United States)

    Chiriki, Siva; Jindal, Shweta; Bulusu, Satya S

    2017-10-21

    For understanding the structure, dynamics, and thermal stability of (AgAu) 55 nanoalloys, knowledge of the composition-temperature (c-T) phase diagram is essential due to the explicit dependence of properties on composition and temperature. Experimentally, generating the phase diagrams is very challenging, and therefore theoretical insight is necessary. We use an artificial neural network potential for (AgAu) 55 nanoalloys. Predicted global minimum structures for pure gold and gold rich compositions are lower in energy compared to previous reports by density functional theory. The present work based on c-T phase diagram, surface area, surface charge, probability of isomers, and Landau free energies supports the enhancement of catalytic property of Ag-Au nanoalloys by incorporation of Ag up to 24% by composition in Au nanoparticles as found experimentally. The phase diagram shows that there is a coexistence temperature range of 70 K for Ag 28 Au 27 compared to all other compositions. We propose the power spectrum coefficients derived from spherical harmonics as an order parameter to calculate Landau free energies.

  15. Homocysteine and the methylenetetrahydrofolate reductase 677C-->T polymorphism in relation to muscle mass and strength, physical performance and postural sway

    NARCIS (Netherlands)

    Swart, K. M. A.; Enneman, A. W.; van Wijngaarden, J. P.; van Dijk, S. C.; Brouwer-Brolsma, E. M.; Ham, A. C.; Dhonukshe-Rutten, R. A. M.; van der Velde, N.; Brug, J.; van Meurs, J. B. J.; de Groot, L. C. P. G. M.; Uitterlinden, A. G.; Lips, P.; van Schoor, N. M.

    2013-01-01

    Elevated plasma homocysteine has been linked to reduced mobility and muscle functioning in the elderly. The relation of methylenetetrahydrofolate reductase (MTHFR) 677C-->T polymorphism with these associations has not yet been studied. This study aimed to investigate (1) the association of plasma

  16. CT staging of colon cancer

    International Nuclear Information System (INIS)

    Dighe, S.; Swift, I.; Brown, G.

    2008-01-01

    Computer tomography (CT) has been the principal investigation in the staging of colon cancers. The information obtained with routine CT has been limited to identifying the site of the tumour, size of the tumour, infiltration into surrounding structures and metastatic spread. The Foxtrot trial National Cancer Research Institute (NCRI) has been specifically designed to evaluate the efficacy of neoadjuvant treatment in colon cancers by using preoperative chemotherapy with or without an anti-Epidermal Growth Factor Receptor (EGFR) monoclonal antibody to improve outcome in high-risk operable colon cancer. Patients are selected based on their staging CT examination. The criteria for poor prognosis are T4 and T3 tumours with more than 5 mm extramural depth. Thus the success of the trial would depend upon the confidence of the radiologist to identify the patients that would receive the neoadjuvant treatment. The aim of this review is to explain the process of identifying high-risk features seen on the staging CT images. This will help to identify a cohort of patients that could truly benefit from neoadjuvant strategies

  17. CT staging of colon cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dighe, S. [Department of Radiology, Royal Marsden Hospital, Sutton SM5 2TT (United Kingdom); Swift, I. [Department of Surgery, Mayday University Hospital, Croydon CR7 7YE (United Kingdom); Brown, G. [Department of Radiology, Royal Marsden Hospital, Sutton SM5 2TT (United Kingdom)], E-mail: gina.brown@rmh.nhs.uk

    2008-12-15

    Computer tomography (CT) has been the principal investigation in the staging of colon cancers. The information obtained with routine CT has been limited to identifying the site of the tumour, size of the tumour, infiltration into surrounding structures and metastatic spread. The Foxtrot trial National Cancer Research Institute (NCRI) has been specifically designed to evaluate the efficacy of neoadjuvant treatment in colon cancers by using preoperative chemotherapy with or without an anti-Epidermal Growth Factor Receptor (EGFR) monoclonal antibody to improve outcome in high-risk operable colon cancer. Patients are selected based on their staging CT examination. The criteria for poor prognosis are T4 and T3 tumours with more than 5 mm extramural depth. Thus the success of the trial would depend upon the confidence of the radiologist to identify the patients that would receive the neoadjuvant treatment. The aim of this review is to explain the process of identifying high-risk features seen on the staging CT images. This will help to identify a cohort of patients that could truly benefit from neoadjuvant strategies.

  18. MR-urography and CT-urography: principles, examination techniques, applications; MR-Urographie und CT-Urographie: Prinzipien, Untersuchungstechniken, Anwendungsmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Adam, G. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Staatz, G.; Wildberger, J. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2003-02-01

    MR-urography (MRU) and CT-urography (CTU) provide refined imaging of the upper urinary tract not achievable with conventional intravenous urography (IVU). The traditional MR-urographic technique utilizes unenhanced, heavily T{sub 2}-weighted turbo spin-echo sequences for obtaining static fluid images of the urinary tract independent of the excretory renal function. T{sub 2}-weighted MR-urograms have proved to be excellent in visualizing the dilated urinary tract, even in non-excreting kidneys. In contrast, T{sub 1}-weighted MRU reflects the excretory renal function and displays the urine flow through the upper tract after renal excretion of an intravenously administered gadolinium chelate. The gadolinium-enhanced urine is visualized with fast T{sub 1}-weighted 3D-gradient-echo sequences. The combination of gadolinium and low-dose furosemide (5-10 mg) is the key for achieving a uniform distribution of gadolinium in the collecting system and for avoiding susceptibility artifacts (T{sub 2}*-effects) in the urine. T{sub 1}-weighted excretory MRU provides impressive urograms of both non-dilated and obstructed collecting systems in patients with normal or moderately impaired renal function. Multislice-CT-urography (MS-CTU) is also an excretory urography like T{sub 1}-weighted MRU. Furthermore, MS-CTU can be combined with low-dose furosemide for accelerated passage of excreted contrast material obviating the need for abdominal compression. CT-urography is limited by its radiation burden and the nephrotoxicity of radiographic contrast media. Combining MRU or MS-CTU with conventional MRI or CT offers several applications, e.g., diagnosis of intrinsic and extrinsic tumors. Meanwhile, MRU has replaced IVU in pediatric uroradiology and is also recommended for the assessment of renal transplants. MS-CTU may provide valuable information in chronic urolithiasis, especially if associated with a distorted urinary tract anatomy. Both MRU and MS-CTU will play an important role in

  19. Serum C-reactive protein and C-reactive gene (-717C>T polymorphism are not associated with periodontitis in Indonesian male patients

    Directory of Open Access Journals (Sweden)

    Antonius Winoto Suhartono

    2015-09-01

    Full Text Available Background: Periodontitis is an inflammatory disease caused by periodontal pathogens and influenced by multiple risk factors such as genetics, smoking habit, age and systemic diseases. The inflammatory cascade is characterized by the release of C-reactive protein (CRP. Periodontitis has been reported to have plausible links to increased level of CRP, which in turn has been associated to elevated risk of  cardiovascular disease (CVD. Purpose: The purpose of this study was t o investigate the relationship amongst the severity of periodontitis, CRP level in blood and CRP (-717 C>T gene polymorphism in male Indonesian smokers and non-smokers. Method: The severity of periodontitis was assessed for 97 consenting male Indonesian smokers and non-smokers. The CRP level of the subjects was determined by using immuno-turbidimetric assay performed in PARAHITA Diagnostic Center Laboratory ISO 9001: 2000 Cert No. 15225/2. The rate of CRP (-717C>T gene polymorphism was determined by using PCR-RFLP in Oral Biology Laboratory, Faculty of Dentistry, Universitas Indonesia. Result: The results suggest that the CRP protein level is not significantly associated with the tested CRP gene polymorphism (p>0.05. Also, while the severity of periodontitis increased significantly with subject age, the CRP level in blood serum was not significantly related to the severity of  periodontitis. The genotypes of the tested polymorphism did not show significant association with the severity of periodontitis either in smokers or in the combined population including smokers and non-smokers. The results naturally do not exclude such associations, but suggest that to discern the differences the sample size must be considerably increased. Conclusion: The CRP (-717C>T gene polymorphism and CRP level in blood serum were not found to be associated with the severity of periodontitis in male smokers or in the combined population of smokers and non-smokers.

  20. Effect ALPHA Globalin Gene Deletion and GAMMA Globin Gene -158 (C/T) Polymorphism in BETA- Thalassaemic Patients

    International Nuclear Information System (INIS)

    EL Serafi, T.I.; Ismail, E.F.; Mahmoud, M.A.; Mohamed, M.A.; Ghattas, M.H.; Badran, D.I.; El Serafi, I.T.; Mohamed, H.S.

    2008-01-01

    The beta-thalassemias (β- thalassemias) are among the most common autosomal recessive disorders. They have a remarkably high frequency in the Mediterranean region and represent one of the most common genetic diseases in Egypt. In this study, the spectrum of P- thalassemia mutations and genotype-to-phenotype correlations were defined in 32 β- thalassaemic patients (β- thalassemias major and intermedia) with varying disease severity in two cities of the Suez Canal region. Ten different mutations were identified and the most frequent ones were: Isi-6 (T-C) (37.5%), IVSI-110 (G-A) (34.4%) and both IVSI-1 (G-A), IVSII-745 (C-G) and -102 (C-G) (12.5% each). There was a wide spectrum of phenotypic severity in all patients. We studied the Xmnl polymorphism (C/T) in γ- globin gene position -158 of P- thalassemia as a modulating factor of the disease severity. Presence of the polymorphism was found in two patients and this was not sufficient to explain the diversity of the phenotype encountered. Co-inheritance of alpha thalassaemia as a modulating factor was not evident in our patients. In conclusion, we have been unable to find a molecular basis for the benign clinical course in all our patients. Other genetic or acquired factors must be hypothesized which ameliorate the clinical condition.

  1. Construction of a voxel model from CT images with density derived from CT numbers

    International Nuclear Information System (INIS)

    Cheng Mengyun; Zeng Qin; Cao Ruifen; Li Gui; Zheng Huaqing; Huang Shanqing; Song Gang; Wu Yican

    2010-01-01

    The voxel models representing human anatomy have been developed to calculate dose distribution in human body, while the density is the most important physical property of voxel model. Traditionally, when creating the Monte Carlo input files, the average tissue parameters recommended in ICRP report were used to assign each voxel in the existing voxel models. However, as each tissue consists of many voxels in which voxels are different in their densities, the method of assigning average tissue parameters doesn't take account of the voxel's discrepancy, and can't represent human anatomy faithfully. To represent human anatomy more faithfully, a method was implemented to assign each voxel, the density of which was derived from CT number. In order to compare with the traditional method, we have constructed two models from a same cadaver specimen date set. A CT-based pelvic voxel model called Pelvis-CT model, was constructed, the densities of which were derived from the CT numbers. A color photograph-based pelvic voxel model called Pelvis-Photo model, was also constructed, the densities of which were taken from ICRP Publication. The CT images and color photographs were obtained from the same female cadaver specimen. The Pelvis-CT and Pelvis-Photo models were ported into Monte Carlo code MCNP to calculate the conversion coefficients from kerma free-in-air to absorbed dose for external monoenergetic photon beams with energies of 0.1, 1 and 10 MeV under anterior-posterior (AP) geometries. The results were compared with those of given in ICRP74. Differences of up to 50% were observed between conversion coefficients of Pelvis-CT and Pelvis-Photo models, moreover the discrepancies decreased for the photon beams with higher energies. The overall trend of conversion coefficients of the Pelvis-CT model were agreed well with that of ICRP74 data. (author)

  2. Mediterranean glucose-6-phosphate dehydrogenase (G6PDC563T) mutation among jordanian females with acute hemolytic crisis

    International Nuclear Information System (INIS)

    Jabbar, A.A.; Kanakiri, N.; Kamil, M.; Rimawi, H.S.A.

    2010-01-01

    To evaluate the G6PDC563T Mediterranean mutation among Jordanian females who were admitted to Princess Rahma Teaching Hospital (PRTH) with/or previous history of favism. Study Design: A descriptive study. Place and Duration of Study: Jordanian University of Science and Technology and PRTH, from October 2003 to October 2004. Methodology: After obtaining approval from the Ethics Committee of Jordanian University of Science and Technology, a total of 32 females were included in this study. Samples from 15 healthy individual females were used as a negative control. Blood samples from these patients were collected and analyzed by allele-specific polymerase chain reaction (AS-PCR) to determine the G6PDC563T mutation. Results: Twenty one out of 32 patients were found to be G6PDC563T Mediterranean mutation (65.6%) positive. Three out of 21 patients were homozygous and remaining 18 were heterozygous for G6PDC563T Mediterranean mutation. Eleven (34.4%) out of 32 patients were found to be negative for G6PDC563T mutation indicating the presence of other G6PD mutations in the study sample. Conclusion: G6PDC563T Mediterranean mutation accounted for 65.6% of the study sample with favism in the North of Jordan. There is likely to be another G6PD deficiency variant implicated in acute hemolytic crisis (favism). (author)

  3. Gadopentate dimeglumine enhanced MR angiography (MRA) for staging AAA: a correlation with DSA and CT

    International Nuclear Information System (INIS)

    Arlart, I.P.; Gerlach, A.; Kolb, M.; Erpenbach, S.; Wuerstlin, S.

    1997-01-01

    Purpose: To evaluate a contrast-enhanced (CE) MRA sequence for staging AAA. Methods: In 24 patients (male=20, female=4, age=44-81 y) with known AAA the abdominal aorta and its branches including the iliac arteries were imaged, using a 3D GRE-FISP sequence (1.5 T, T R /T E /FA=25/6/35, slab=100-140 mm, 32 part., FOV=440-450 mm, matrix=256x256) during an i.v. infusion of 40 ml of gadopentate dimeglumine. In addition, representative axial single slices (2D breathhold FLASH-sequence: T R /T E /FA=82/5/30) were acquired following contrast application. MR-results were correlated with i.a. DSA and CT studies. Results: With CE-MRA, AAA (n=24) and iliac aneurysms (n=17) could be evaluated in all cases (sens.=100%, spec.=100%) including luminal patency and mural thrombus. 50/54 renal arteries could be identified, 4/6 accessory renal arteries (sens=66,6%, spec.=100%), 8/9 renal artery stenoses>50% (sens.=88.8%, spec.=89.3%), 1/1 renal artery occlusion and 7/8 iliac artery stenoses>50% (sens.=87.5%, spec.=97.5%) were depicted correctly. Proximal portion of sup. mes. art. could be detected and evaluated in 21/24 cases. Quantitative determination of therapeutically relevant vascular paramters using MRA was comparable to DSA and CT. (orig./AJ) [de

  4. Single Nucleotide Polymorphisms of the GJB2 and GJB6 Genes Are Associated with Autosomal Recessive Nonsyndromic Hearing Loss

    Directory of Open Access Journals (Sweden)

    Ana Paula Grillo

    2015-01-01

    Full Text Available Single nucleotide polymorphisms (SNPs are important markers in many studies that link DNA sequence variations to phenotypic changes; such studies are expected to advance the understanding of human physiology and elucidate the molecular basis of diseases. The DFNB1 locus, which contains the GJB2 and GJB6 genes, plays a key role in nonsyndromic hearing loss. Previous studies have identified important mutations in this locus, but the contribution of SNPs in the genes has not yet been much investigated. The aim of this study was to investigate the association of nine polymorphisms located within the DFNB1 locus with the occurrence of autosomal recessive nonsyndromic hearing loss (ARNSHL. The SNPs rs3751385 (C/T, rs7994748 (C/T, rs7329857 (C/T, rs7987302 (G/A, rs7322538 (G/A, rs9315400 (C/T, rs877098 (C/T, rs945369 (A/C, and rs7333214 (T/G were genotyped in 122 deaf patients and 132 healthy controls using allele-specific PCR. There were statistically significant differences between patients and controls, in terms of allelic frequencies in the SNPs rs3751385, rs7994748, rs7329857, rs7987302, rs945369, and rs7333214 (P<0.05. No significant differences between the two groups were observed for rs7322538, rs9315400, and rs877098. Our results suggest that SNPs present in the GJB2 and GJB6 genes may have an influence on ARNSHL in humans.

  5. Application of fire-retardant treatment to the wood in Type A unirradiated nuclear fuel outer containers

    International Nuclear Information System (INIS)

    Whitlow, J.D.; Luna, R.E.

    1992-01-01

    Packagings for transporting unirradiated nuclear fuel assemblies in the United States are commonly constructed as rectangular boxes consisting of a metal inner container, a wooden outer container, and cushioning material separating the two. The wood in the outer container is a potential source of fuel for fire. Use of a fire-retardant treatment on the wood may reduce or eliminate the damage to nuclear fuel assemblies in some types of accidents involving fire. The applicability of using fire-retardant treatments on the wood of outer containers is addressed. An approximate cost-benefit analysis to determine if fire-retardant treatments are economically justified is presented. (Author)

  6. Frequency of interleukin 28B rs12979860 C>T variants in Filipino patients chronically infected with hepatitis B virus.

    Science.gov (United States)

    Baclig, Michael O; Reyes, Karen G; Mapua, Cynthia A; Gopez-Cervantes, Juliet; Natividad, Filipinas F

    2015-03-01

    Hepatitis B virus (HBV) is one of the most prevalent viral infections worldwide. Nearly 400 million individuals are chronic carriers of HBV. The aim of the present study was to determine the frequency of human interleukin 28B (IL28B) variants among treatment naive Filipino patients clinically diagnosed with chronic hepatitis B (CHB), and to compare the IL28B frequency distribution with various ethnic populations. Fifty-seven CHB patients and 43 normal controls were enrolled in this study. Real-time PCR was performed using the TaqMan genotyping assay for IL28B rs12979860. The allelic frequencies among normal controls were 0.94 and 0.06 for the IL28B rs12979860 C and T alleles, respectively. Eighty-eight percent were identified as homozygous for the IL28B C/C genotype and 12% were identified as heterozygous for the IL28B C/T genotype. Among CHB patients, the allelic frequencies were 0.90 for the IL28B C allele and 0.10 for the IL28B T allele. No IL28B T/T genotype was observed between the two groups. No significant difference in the distribution of IL28B genotypes was observed between normal controls and CHB patients. Allelic frequencies of IL28B among Filipinos were similar with other Asian populations but significantly different from Caucasians. The frequency of rs12979860 C>T variants among Filipino CHB patients has not yet been reported. These data provided new insight into the geographical frequency distribution of IL28B variants. Further studies are needed to determine the possible association between IL28B variants and response to pegylated-interferon-α plus ribavirin combination therapy among Filipino patients chronically infected with HBV.

  7. Image-Based Treatment Planning of the Post-Lumpectomy Breast Utilizing CT and 3TMRI

    International Nuclear Information System (INIS)

    Jacobson, G.; Betts, V.; Muruganandham, M.; Buechler-Price, J.; Zamba, G.

    2011-01-01

    Accurate lumpectomy cavity definition is critical in breast treatment planning. We compared contouring lumpectomy cavity volume and cavity visualization score (CVS) with CT versus 3T MRI. 29 patients were imaged with CT and 3T MRI. Seven additional boost planning sets were obtained for 36 image sets total. Three observers contoured the lumpectomy cavity on all images, assigning a cavity visualization score (CVS ) of 1 to 5. Measures of consistency and agreement for CT volumes were 98.84% and 98.62%, for T1 MRI were 95.65% and 95.55%, and for T2 MRI were 97.63% and 97.71%. The mean CT, T1 MRI, and T2 MRI CVS scores were 3.28, 3.38, and 4.32, respectively. There was a highly significant difference between CT and T2 scores (P<.00001) and between T1 and T2 scores (P<.00001). Interobserver consistency and agreement regarding volumes were high for all three modalities with T2 MRI CVS the highest. MRI may contribute to target definition in selected patients

  8. Image-Based Treatment Planning of the Post-Lumpectomy Breast Utilizing CT and 3TMRI

    Directory of Open Access Journals (Sweden)

    Geraldine Jacobson

    2011-01-01

    Full Text Available Accurate lumpectomy cavity definition is critical in breast treatment planning. We compared contouring lumpectomy cavity volume and cavity visualization score (CVS with CT versus 3T MRI. 29 patients were imaged with CT and 3T MRI. Seven additional boost planning sets were obtained for 36 image sets total. Three observers contoured the lumpectomy cavity on all images, assigning a cavity visualization score (CVS of 1 to 5. Measures of consistency and agreement for CT volumes were 98.84% and 98.62%, for T1 MRI were 95.65% and 95.55%, and for T2 MRI were 97.63% and 97.71%. The mean CT, T1 MRI, and T2 MRI CVS scores were 3.28, 3.38, and 4.32, respectively. There was a highly significant difference between CT and T2 scores (<.00001 and between T1 and T2 scores (<.00001. Interobserver consistency and agreement regarding volumes were high for all three modalities with T2 MRI CVS the highest. MRI may contribute to target definition in selected patients.

  9. Kinetics of thermal decomposition of γ-irradiated and unirradiated complexes of mandelhydroxamic acid

    International Nuclear Information System (INIS)

    Hassan, R.M.; Farid, T.; El-Bellihi, A.A.

    1992-01-01

    The thermal decomposition of γ-irradiated and unirradiated complexes of mandelhydroxamic acid (HMA), Co (HMA) 2 .1/2H 2 O, Mn (HMA) 2 .2H 2 O, Ba (HMA) 2 .2H 2 O and Cd (HMA) 2 .2H 2 O have been studied thermogravimetrically (under isothermal conditions). The thermal dehydration of each complex occured in one step, while the decomposition of dehydrated complexes occured in two steps. The kinetic parameters for dehydration were computed by different models. The thermal dehydration is regulated by random nucleation A 3 for Co-, Mn-, and Cd-complexes and by phase-boundary (R 3 ) for Ba-complex. The effect of γ-irradiation on the kinetic parameters of thermal decomposition is discussed. Radiation did not modify the mechanism of the reaction but accelarated the dehydration steps in the case of Mn- and Co-complexes. (author) 7 refs.; 1 fig.; 4 tabs

  10. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  11. CT in neuromuscular disorders: A comparison of CT and histology

    International Nuclear Information System (INIS)

    Vliet, A.M. van der; Thijssen, H.O.M.; Merx, J.L.; Joosten, E.

    1988-01-01

    The value of CT-examination of the muscles compared to histology was studied in a retrospective analysis of 30 patients with clinical suspicion of neuromuscular disorder. In the evaluation of the CT-results descriptive criteria were used. The histologic diagnosis came from needle-biopsies taken from the quadriceps muscle. Considering the whole group of neuromuscular disorders, CT has an overall accuracy of 84.8%, a positive predictive value of 95.5% and a negative predictive value of 63.6%. This makes the use of CT as a diagnostic tool in neuromuscular disorders a reliable examination technique. In patients with a polymyositis there is even a 100% correlation between CT findings and biopsy results. Discrepancy between the biopsy results is remarkable of the quadriceps muscle and the CT findings: The number of abnormal histological findings is twice the number of abnormal CT findings. Using the more proximal gluteal region as a biopsy site would have decreased this discrepancy and would therefore have given a better correlation between CT and histology. The choice of protocol in determining the levels to be scanned is of great importance in achieving good reproducability in follow-up CT examinations. (orig.)

  12. Improved correlation between CT emphysema quantification and pulmonary function test by density correction of volumetric CT data based on air and aortic density

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Soo [Department of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine (Korea, Republic of); Seo, Joon Beom, E-mail: seojb@amc.seoul.kr [Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of); Kim, Namkug; Chae, Eun Jin [Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of); Lee, Young Kyung [Department of Radiology, Kyung Hee University Hospital at Gangdong (Korea, Republic of); Oh, Yeon Mok; Lee, Sang Do [Division of Pulmonology, Department of Internal Medicine, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of)

    2014-01-15

    Objectives: To determine the improvement of emphysema quantification with density correction and to determine the optimal site to use for air density correction on volumetric computed tomography (CT). Methods: Seventy-eight CT scans of COPD patients (GOLD II–IV, smoking history 39.2 ± 25.3 pack-years) were obtained from several single-vendor 16-MDCT scanners. After density measurement of aorta, tracheal- and external air, volumetric CT density correction was conducted (two reference values: air, −1000 HU/blood, +50 HU). Using in-house software, emphysema index (EI) and mean lung density (MLD) were calculated. Differences in air densities, MLD and EI prior to and after density correction were evaluated (paired t-test). Correlation between those parameters and FEV{sub 1} and FEV{sub 1}/FVC were compared (age- and sex adjusted partial correlation analysis). Results: Measured densities (HU) of tracheal- and external air differed significantly (−990 ± 14, −1016 ± 9, P < 0.001). MLD and EI on original CT data, after density correction using tracheal- and external air also differed significantly (MLD: −874.9 ± 27.6 vs. −882.3 ± 24.9 vs. −860.5 ± 26.6; EI: 16.8 ± 13.4 vs. 21.1 ± 14.5 vs. 9.7 ± 10.5, respectively, P < 0.001). The correlation coefficients between CT quantification indices and FEV{sub 1}, and FEV{sub 1}/FVC increased after density correction. The tracheal air correction showed better results than the external air correction. Conclusion: Density correction of volumetric CT data can improve correlations of emphysema quantification and PFT.

  13. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

    Science.gov (United States)

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Theysohn, Jens; Wetter, Axel

    2018-03-28

    To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose index vol (CTDI vol ); dose-length product (DLP body ); size-specific dose estimate (SSDE)] were also compared. Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

  14. Prevalence of latent and manifest hyperthyroidism in an iodine-deficient area: non-selected patient population admitted for CT studies with iodine-containing contrast agents

    International Nuclear Information System (INIS)

    Saam, T.; Hess, T.; Kasperk, C.; Kauffmann, G.W.; Duex, M.

    2005-01-01

    Purpose: to evaluate the prevalence of latent and manifest hyperthyroidism in a non-selected group of patients admitted for contrast enhanced CT studies blood samples were tested for the levels of thyroid-stimulating hormone (TSH). Material and methods: TSH blood levels were obtained in 548 consecutive patients who were scheduled for contrast-enhanced (Iopromide; 300 mg iodine/ml) CT scanning. In case of TSH levels registered (sodium perchlorate) was commenced before scanning. In case of TSH levels < 0.1 mU/l, CT scanning was not performed but further evaluation of the thyroid function was initiated. Results: TSH blood levels ranged from 0.4 to 7.5 mU/l in 512 patients, and 36 patients (6.6%) had TSH blood levels < 0.4 mU/l and 9 patients blood levels < 0.1 mU/l, with 32 of those patients (5.8%) having regular T3 and T4 blood levels consistent with latent hyperthyroidism. In 4 patients (0.8%), T3 or T4 blood levels were increased consistent with manifest hyperthyroidism. Conclusion: in South Germany, the prevalence of latent or manifest hyperthyroidism in a non-selected patient group is high. Therefore TSH blood levels should be obtained prior to contrast-enhanced CT studies. (orig.)

  15. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  16. To investigate the necessity of STRA6 upregulation in T cells during T cell immune responses.

    Directory of Open Access Journals (Sweden)

    Rafik Terra

    Full Text Available Our earlier study revealed that STRA6 (stimulated by retinoic acid gene 6 was up-regulated within 3 h of TCR stimulation. STRA6 is the high-affinity receptor for plasma retinol-binding protein (RBP and mediates cellular vitamin A uptake. We generated STRA6 knockout (KO mice to assess whether such up-regulation was critical for T-cell activation, differentiation and function. STRA6 KO mice under vitamin A sufficient conditions were fertile without apparent anomalies upon visual inspection. The size, cellularity and lymphocyte subpopulations of STRA6 KO thymus and spleen were comparable to those of their wild type (WT controls. KO and WT T cells were similar in terms of TCR-stimulated proliferation in vitro and homeostatic expansion in vivo. Naive KO CD4 cells differentiated in vitro into Th1, Th2, Th17 as well as regulatory T cells in an analogous manner as their WT counterparts. In vivo experiments revealed that anti-viral immune responses to lymphocytic choriomeningitis virus in KO mice were comparable to those of WT controls. We also demonstrated that STRA6 KO and WT mice had similar glucose tolerance. Total vitamin A levels are dramatically lower in the eyes of KO mice as compared to those of WT mice, but the levels in other organs were not significantly affected after STRA6 deletion under vitamin A sufficient conditions, indicating that the eye is the mouse organ most sensitive to the loss of STRA6. Our results demonstrate that 1 in vitamin A sufficiency, the deletion of STRA6 in T cells does no affect the T-cell immune responses so-far tested, including those depend on STAT5 signaling; 2 STRA6-independent vitamin A uptake compensated the lack of STRA6 in lymphoid organs under vitamin A sufficient conditions in mice; 3 STRA6 is critical for vitamin A uptake in the eyes even in vitamin A sufficiency.

  17. Flow sheet development for the dissolution of unirradiated Mark 42 fuel tubes in F-Canyon, Part II

    International Nuclear Information System (INIS)

    Murray, A.M.

    1999-01-01

    Two dissolution flow sheets were tested for the desorption of unirradiated Mark 42 fuel tubes. Both the aluminum (from the can, cladding, and fuel core) and the plutonium oxide (PuO 2 ) are dissolved simultaneously, i.e., a co-dissolution flow sheet. In the first series of tests, 0.15 and 0.20 molar (M) potassium fluoride (KF) solutions were used and the dissolution extended over several days. In the other series of tests, solutions with higher concentrations of fluoride (0.25 to 0.30 M) were used. Calcium fluoride (CaF 2 ) was used in those tests as the fluoride source

  18. Investigating the generalisation of an atlas-based synthetic-CT algorithm to another centre and MR scanner for prostate MR-only radiotherapy

    Science.gov (United States)

    Wyatt, Jonathan J.; Dowling, Jason A.; Kelly, Charles G.; McKenna, Jill; Johnstone, Emily; Speight, Richard; Henry, Ann; Greer, Peter B.; McCallum, Hazel M.

    2017-12-01

    There is increasing interest in MR-only radiotherapy planning since it provides superb soft-tissue contrast without the registration uncertainties inherent in a CT-MR registration. However, MR images cannot readily provide the electron density information necessary for radiotherapy dose calculation. An algorithm which generates synthetic CTs for dose calculations from MR images of the prostate using an atlas of 3 T MR images has been previously reported by two of the authors. This paper aimed to evaluate this algorithm using MR data acquired at a different field strength and a different centre to the algorithm atlas. Twenty-one prostate patients received planning 1.5 T MR and CT scans with routine immobilisation devices on a flat-top couch set-up using external lasers. The MR receive coils were supported by a coil bridge. Synthetic CTs were generated from the planning MR images with (sCT1V ) and without (sCT) a one voxel body contour expansion included in the algorithm. This was to test whether this expansion was required for 1.5 T images. Both synthetic CTs were rigidly registered to the planning CT (pCT). A 6 MV volumetric modulated arc therapy plan was created on the pCT and recalculated on the sCT and sCT1V . The synthetic CTs’ dose distributions were compared to the dose distribution calculated on the pCT. The percentage dose difference at isocentre without the body contour expansion (sCT-pCT) was Δ D_sCT=(0.9 +/- 0.8) % and with (sCT1V -pCT) was Δ D_sCT1V=(-0.7 +/- 0.7) % (mean  ±  one standard deviation). The sCT1V result was within one standard deviation of zero and agreed with the result reported previously using 3 T MR data. The sCT dose difference only agreed within two standard deviations. The mean  ±  one standard deviation gamma pass rate was Γ_sCT = 96.1 +/- 2.9 % for the sCT and Γ_sCT1V = 98.8 +/- 0.5 % for the sCT1V (with 2% global dose difference and 2~mm distance to agreement gamma criteria). The one voxel body contour

  19. CT numbers of liver and spleen in normal children

    International Nuclear Information System (INIS)

    Kim, Young Kim

    2002-01-01

    To determine the mean liver CT numbers, and differences between liver and spleen, and liver and back muscle CT numbers in normal children, and to correlate the findings with sex and age. One hundred and five normal children aged 2-14 years underwent pre-contrast CT scanning. Mean CT numbers of the liver, spleen, and back muscles were calculated, as well as the differences in CT numbers between the liver and spleen (liver-spleen CT numbers), and between the liver-back muscle CT numbers were 70.22±6.51 HU, 53.28±3.57 HU, 17.13±6.57 HU, and 11.88±5.94 HU, respectively. Mean liver CT numbers and the difference between liver and back muscle CT numbers were not different by age. By sex, all the CT numbers did not vary according to age. The sex of a subject did not affect the CT number. The children's mean liver CT number was 70.22±6.51 HU and the difference between liver and spleen CT numbers was 17.13±6.57 HU. Younger children had higher liver CT and liver-spleen CT numbers than older children. No CT numbers varied according to sex

  20. Recovery of the accumulation ability of thiomethyl-β-galactoside in Escherichia coli after bacteriophage T4 infection

    International Nuclear Information System (INIS)

    Saijo, N.; Okamoto, K.

    1976-01-01

    Effects of uv-irradiated and unirradiated T4 phage infection on the β-galactoside accumulation ability in Escherichia coli have been examined by the use of 14 C-labeled thiomethyl-β-galactoside (TMG). Under conditions where a synchronous adsorption of phage takes place, the cellular ability for TMG accumulation is found to be largely inhibited immediately after phage adsorption but it recovers with time to a new level, which is dependent on the multiplicity of infection. When cells are infected with uv-irradiated T4 at the same multiplicity as that of unirradiated phage, the cellular accumulation ability is more severely inhibited and there is no recovery from the inhibition. The recovery process in T4-infected cells is mostly sensitive to puromycin. These results suggest that the initial inhibition of the TMG accumulation ability is probably caused by the adsorption of phage coats, and the subsequent restoration occurs through the action of a phage-directed protein(s). In the recovery process, no new transport system appears to be involved. The restored ability of TMG accumulation is resistant to the action of superinfecting uv phage. However, different mechanisms appear to be operating in T4-infected cells for the establishment of resistance to ghosts and for the recovery from the phage coat-induced inhibition

  1. Cone-Beam Computed Tomography (CBCT) Versus CT in Lung Ablation Procedure: Which is Faster?

    Science.gov (United States)

    Cazzato, Roberto Luigi; Battistuzzi, Jean-Benoit; Catena, Vittorio; Grasso, Rosario Francesco; Zobel, Bruno Beomonte; Schena, Emiliano; Buy, Xavier; Palussiere, Jean

    2015-10-01

    To compare cone-beam CT (CBCT) versus computed tomography (CT) guidance in terms of time needed to target and place the radiofrequency ablation (RFA) electrode on lung tumours. Patients at our institution who received CBCT- or CT-guided RFA for primary or metastatic lung tumours were retrospectively included. Time required to target and place the RFA electrode within the lesion was registered and compared across the two groups. Lesions were stratified into three groups according to their size (20 mm). Occurrences of electrode repositioning, repositioning time, RFA complications, and local recurrence after RFA were also reported. Forty tumours (22 under CT, 18 under CBCT guidance) were treated in 27 patients (19 male, 8 female, median age 67.25 ± 9.13 years). Thirty RFA sessions (16 under CBCT and 14 under CT guidance) were performed. Multivariable linear regression analysis showed that CBCT was faster than CT to target and place the electrode within the tumour independently from its size (β = -9.45, t = -3.09, p = 0.004). Electrode repositioning was required in 10/22 (45.4 %) tumours under CT guidance and 5/18 (27.8 %) tumours under CBCT guidance. Pneumothoraces occurred in 6/14 (42.8 %) sessions under CT guidance and in 6/16 (37.5 %) sessions under CBCT guidance. Two recurrences were noted for tumours receiving CBCT-guided RFA (2/17, 11.7 %) and three after CT-guided RFA (3/19, 15.8 %). CBCT with live 3D needle guidance is a useful technique for percutaneous lung ablation. Despite lesion size, CBCT allows faster lung RFA than CT.

  2. CT manifestation of peritoneal metastasis

    International Nuclear Information System (INIS)

    Cha, Soon Joo; Kang, Eun Young; Suh, Won Hyuck

    1989-01-01

    Peritoneal metastasis is frequent mode of dissemination of intraabdominal malignancies. Radiologic diagnosis of peritoneal metastasis has relied on indirect evidence on a barium UGI series and small bowel examination. With the advent of CT scanning, CT is capable of direct imaging of peritoneum. The sensitivity of CT in detecting peritoneal metastasis and CT manifestation of peritoneal metastatic lesions had reported occasionally, but rarely in Korea. So, authors illustrated the CT manifestation of peritoneal metastatic lesions in 32 cases of macroscopically proven cases in laparoscopy or laparotomy in Korea University Hae Wha Hospital during recent 4 years. The results are as follows. 1. Of total 32 cases, 18 cases were male and 14 cases were female. Age incidence was the most common in 6th decade. 2. The most common type of malignancy that cause peritoneal metastasis was the stomach cancer and next common type of malignancies were pancreas cancer in men and ovarian cancer in women. 3. Of total 32 cases of peritoneal metastasis which was confirmed by laparoscopy or laparotomy macroscopically, 23 cases (72%) were detected peritoneal thickening and/or omental pathology by CT, and the remaining 9 cases (28%) were not detected by CT. 4. Ascites was present in 19 cases (59%). 5. Parietal peritoneal thickening was present in 16 cases (50%) by CT and sheetlike pattern was the most common findings. The patterns of peritoneal thickening was relatively nonspecific and was not correlated with primary tumor type. 6. Tumor involvement of greater omentum by CT was present in 19 cases (59%). There were 7 cases of smudged appearance pattern, 6 cases of nodular pattern, 6 cases of omental cake pattern and no cystic mass pattern. The patterns of omental pathology was relatively nonspecific and was nor correlated with primary tumor type

  3. [C677T polymorphism of the methylentetrahydrofolate reductase gene in mothers of children affected with neural tube defects].

    Science.gov (United States)

    Morales de Machín, Alisandra; Méndez, Karile; Solís, Ernesto; Borjas de Borjas, Lisbeth; Bracho, Ana; Hernández, María Luisa; Negrón, Aimara; Delgado, Wilmer; Sánchez, Yanira

    2015-09-01

    Neural tube defects (NTD) are the most common congenital anomalies of the central nervous system, with a multifactorial pattern of inheritance, presumably involving the interaction of several genetic and environmental factors. The methylenetetrahydrofolate reductase (MTHFR) gene 677C>T polymorphism has been implicated as a risk factor for NTD. The main objective of this research was to investigate the association of the 677C>T polymorphism of the MTHFR gene as a genetic risk factor for NTD. Molecular analysis was performed in DNA samples from 52 mothers with antecedent of NTD offspring and from 119 healthy control mothers. Using the Polymerase Chain Reaction, a 198 bases pairs fragment was digested with the restriction enzyme Hinfi. 677T MTHFR allele frequencies for the problem and the control groups were 51.92% and 34.45%, respectively, and 677C MTHFR allele frequencies were 48.08% and 65.55%, respectively. There were significant differences in allele (p: 0.002) and genotype (p: 0.007) frequencies between these two groups. The odds ratio (OR) to the TT genotype vs. the CC genotype was estimated as OR: 4.9 [95% CI: 1,347-6.416] p: 0.002; CT+TT vs. CC: OR: 2.9 [95% CI: 1.347-6.416] p: 0.005; TT vs. CT+CC: OR: 2.675 [95% CI: 1,111-6.441] p: 0.024. The data presented in this study support the relationship between MTHFR 677C>T polymorphism and risk in mothers with antecedent of NTD offspring.

  4. Zero-Echo-Time and Dixon Deep Pseudo-CT (ZeDD CT): Direct Generation of Pseudo-CT Images for Pelvic PET/MRI Attenuation Correction Using Deep Convolutional Neural Networks with Multiparametric MRI.

    Science.gov (United States)

    Leynes, Andrew P; Yang, Jaewon; Wiesinger, Florian; Kaushik, Sandeep S; Shanbhag, Dattesh D; Seo, Youngho; Hope, Thomas A; Larson, Peder E Z

    2018-05-01

    Accurate quantification of uptake on PET images depends on accurate attenuation correction in reconstruction. Current MR-based attenuation correction methods for body PET use a fat and water map derived from a 2-echo Dixon MRI sequence in which bone is neglected. Ultrashort-echo-time or zero-echo-time (ZTE) pulse sequences can capture bone information. We propose the use of patient-specific multiparametric MRI consisting of Dixon MRI and proton-density-weighted ZTE MRI to directly synthesize pseudo-CT images with a deep learning model: we call this method ZTE and Dixon deep pseudo-CT (ZeDD CT). Methods: Twenty-six patients were scanned using an integrated 3-T time-of-flight PET/MRI system. Helical CT images of the patients were acquired separately. A deep convolutional neural network was trained to transform ZTE and Dixon MR images into pseudo-CT images. Ten patients were used for model training, and 16 patients were used for evaluation. Bone and soft-tissue lesions were identified, and the SUV max was measured. The root-mean-squared error (RMSE) was used to compare the MR-based attenuation correction with the ground-truth CT attenuation correction. Results: In total, 30 bone lesions and 60 soft-tissue lesions were evaluated. The RMSE in PET quantification was reduced by a factor of 4 for bone lesions (10.24% for Dixon PET and 2.68% for ZeDD PET) and by a factor of 1.5 for soft-tissue lesions (6.24% for Dixon PET and 4.07% for ZeDD PET). Conclusion: ZeDD CT produces natural-looking and quantitatively accurate pseudo-CT images and reduces error in pelvic PET/MRI attenuation correction compared with standard methods. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  5. Histological grade of differentiation of hepatocellular carcinoma: comparison of the efficacy of diffusion-weighted MRI with T2-weighted imaging and angiography-assisted CT

    International Nuclear Information System (INIS)

    Saito, Kazuhiro; Nishio, Ryota; Saguchi, Toru; Akata, Soichi; Tokuuye, Koichi; Moriyasu, Fuminori; Sugimoto, Katsutoshi

    2012-01-01

    The purpose of this study is to determine the usefulness of diffusion-weighted imaging (DWI) for evaluating the histological grade of differentiation of hepatocellular carcinoma (HCC) compared with T2-weighted imaging (T2WI) and tumour haemodynamics. We retrospectively evaluated 32 patients with 42 pathologically confirmed HCC nodules. These patients underwent MRI, CT during arterial portography and CT hepatic arteriography. We evaluated the relationship between the histological grade of differentiation and the apparent diffusion coefficient (ADC) values, conspicuity of tumour on DWI, DWI and T2WI contrast-to-noise (C/N) ratios and tumour haemodynamics. There was no correlation between the histological grade of differentiation and the ADC values. The DWI C/N ratio was significantly different among all histological grades, but the T2WI C/N ratio was not. Tumour conspicuity on DWI correlated well with the histological grade of differentiation, but tumour haemodynamics only partially correlated with the histological grade of differentiation. DWI was useful for evaluating the histological grade of differentiation of HCC.

  6. Interrupted thymidylate synthase gene of bacteriophages T2 and T6 and other potential self-splicing introns in the T-even bacteriophages

    International Nuclear Information System (INIS)

    Chu, F.K.; Maley, F.; Martinez, J.; Maley, G.F.

    1987-01-01

    Southern hybridization analyses of procaryotic DNA from Escherchia coli, λ bacteriophage, and T1 to T7 phages were carried out. The hybridization probes used consisted of DNA restriction fragments derived from the T4 phage intron-containing thymidylate synthase gene (td) and short synthetic oligodeoxynucleotides defining specific exon and intron regions of the gene. It was shown that intact as well as restricted DNA from the T-even phages hybridized not only to both T4 phage td intron- and exon-specific probes but also to probes defining the td 5' (exon I-intron) and 3' (intron-exon II) presplice junctions. These data strongly suggest that, analogous to the T4 phage, only the T2 and T6 phages among the procaryotes tested contain interrupted td genes. The td intervening sequence in each phage is roughly 1 kilobase pair (kb) in size and interrupts the td gene at a site analogous to that in the T4 phage. This was confirmed by data from Northern (RNA) hybridization analysis of td-specific in vitro transcripts of these phage DNAs. [α- 32 P]GTP in vitro labeling of total RNA from T4 phage-infected cells produced five species of labeled RNAs that were 1, 0.9, 0.83, 0.75, and 0.6 kb in size. Only the 1-, 0.9-, and 0.75-kb species were labeled in RNA from T2- or T6-infected cells. The commonly present 1-kb RNA is the excised td intron, which exists in both linear and circular forms in the respective T-even-phage-infected cells, while the 0.6-kb RNA unique to T4 may be the excised intron derived from the ribonucleotide reductase small subunit gene (nrdB) of the phage. The remaining labeled RNA species are likely candidates for other self-splicing introns

  7. Combined Corrosion and Wear of Aluminium Alloy 7075-T6

    NARCIS (Netherlands)

    Liu, Y.; Mol, J.M.C.; Janssen, G.C.A.M.

    2016-01-01

    The aluminium alloy 7075-T6 is widely used in engineering. In some applications, like slurry transport, corrosion and abrasion occur simultaneously, resulting in early material failure. In the present work, we investigated the combined effect of corrosion and wear on the aluminium alloy 7075-T6. We

  8. Evaluation of staphylococcus aureus growth in unirradiated and irradiated cured meats using the Gompertz equation

    International Nuclear Information System (INIS)

    Szczawinski, J.; Szczawinska, M.

    1993-01-01

    1. Sodium nitrite, in concentration of 156 mg/kg, exerted little (from practical point of view) inhibitory effect on S. aureus in cured meat. Its addition caused lag time extension, increase of exponential growth rate, decrease of generation time and maximum population density of staphylococci in samples of cured meat stored at 20 C. 2. Growth curves of Staphylococcus aureus in unirradiated and irradiated (50 kGy) meats cured without sodium nitrite were similar. 3. Irradiation of meat cured with 156 mg/kg sodium nitrite with increasing doses of ionizing radiation (0, 10, 30, 50 kGy) progressively decreased growth rates and lag time and increased generation time and maximum population densities of Staphylococcus aureus in samples inoculated after radiation treatment and incubated at 20 C. (orig.)

  9. Enrichment Of Volcanogenic Trace Elements, Co, Cr, Cu, Ni, Mo And Zr In A Continuous Subsurface Eagle Ford Core In South Texas And Origin Of The Oceanic Anoxic Event II At The Cenomanian-Turonian (C/T) Boundary

    Science.gov (United States)

    Valencia, D.; Basu, A. R.; Loocke, M. P.

    2017-12-01

    The Eagle Ford Formation containing the Cenomanian-Turonian (C/T) boundary continues to be studied globally not only for its economic potential and analog for `frack-able' unconventional organic-rich formations, but it is of particular interest to researchers because it was deposited across the C/T boundary recording an Oceanic Anoxic Event (OAE2). OAEs are short lived episodes (matter into the sedimentary record remains enigmatic. Geochemical and geochronological analysis of a subsurface 300ft long continuous core of the Eagle Ford Formation of South Texas shows evidence for volcanism throughout. This is confirmed by multiple thin intermittent bentonite beds. The whole rock black shale (marl) shows elevated concentrations of volcanogenic trace elements (Co, Cr, Cu, Ni, Mo and Zn) throughout the core. By sampling bentonite bed zircons near the inferred C/T boundary, U-Pb age of 93.2 ±1.7 Ma for the Eagle Ford is established. Using this horizon, the onset of OAE2 is constrained and well-correlated with the positive δ13C excursion. For the trace element analysis, the core was sampled at 10ft intervals for ICP-MS. The analytical results show significantly increased volcanogenic trace metal input correlating with increased Total Organic Carbon and positive δ13C values at the C/T dated zircon horizon. OAE2, defined by the positive δ13C excursion, was found to span over an interval of 85ft. With a definitive constraint for OAE2 established, this well-defined interval was analyzed at a much higher resolution using ED-XRF. The core was then sampled at 6' intervals throughout the C/T boundary at OAE2. The high-resolution sampling of the core shows 80-99% increase in abundance of Co, Cr, Cu, Ni, Mo, Zn over the average Post Australian Archean Shale(PAAS), representative of average continental crust. These volcanogenic-rich intervals reach peak values before the onset of OAE2 and at the maximum values for the positive δ13C isotope excursion directly after the 93.2 ±1

  10. Adaptive statistical iterative reconstruction technology in the application of PET/CT whole body scans

    International Nuclear Information System (INIS)

    Xin Jun; Zhao Zhoushe; Li Hong; Lu Zhe; Wu Wenkai; Guo Qiyong

    2013-01-01

    Objective: To improve image quality of low dose CT in whole body PET/CT using adaptive statistical iterative reconstruction (ASiR) technology. Methods: Twice CT scans were performed with GE water model,scan parameters were: 120 kV, 120 and 300 mA respectively. In addition, 30 subjects treated with PET/CT were selected randomly, whole body PET/CT were performed after 18 F-FDG injection of 3.70 MBq/kg, Sharp IR+time of flight + VUE Point HD technology were used for 1.5 min/bed in PET; CT of spiral scan was performed under 120 kV using automatic exposure control technology (30-210 mA, noise index 25). Model and patients whole body CT images were reconstructed with conventional and 40% ASiR methods respectively, and the CT attenuation value and noise index were measured. Results: Research of model and clinical showed that standard deviation of ASiR method in model CT was 33.0% lower than the conventional CT reconstruction method (t =27.76, P<0.01), standard deviation of CT in normal tissues (brain, lung, mediastinum, liver and vertebral body) and lesions (brain, lung, mediastinum, liver and vertebral body) reduced by 21.08% (t =23.35, P<0.01) and 24.43% (t =16.15, P<0.01) respectively, especially for normal liver tissue and liver lesions, standard deviations of CT were reduced by 51.33% (t=34.21, P<0.0) and 49.54% (t=15.21, P<0.01) respectively. Conclusion: ASiR reconstruction method was significantly reduced the noise of low dose CT image and improved the quality of CT image in whole body PET/CT, which seems more suitable for quantitative analysis and clinical applications. (authors)

  11. Repeated cycles of 5-fluorouracil chemotherapy impaired anti-tumor functions of cytotoxic T cells in a CT26 tumor-bearing mouse model.

    Science.gov (United States)

    Wu, Yanhong; Deng, Zhenling; Wang, Huiru; Ma, Wenbo; Zhou, Chunxia; Zhang, Shuren

    2016-09-20

    Recently, the immunostimulatory roles of chemotherapeutics have been increasingly revealed, although bone marrow suppression is still a common toxicity of chemotherapy. While the numbers and ratios of different immune subpopulations are analyzed after chemotherapy, changes to immune status after each cycle of treatment are less studied and remain unclear. To determine the tumor-specific immune status and functions after different cycles of chemotherapy, we treated CT26 tumor-bearing mice with one to four cycles of 5-fluorouracil (5-FU). Overall survival was not improved when more than one cycle of 5-FU was administered. Here we present data concerning the immune statuses after one and three cycles of chemotherapy. We analyzed the amount of spleen cells from mice treated with one and three cycles of 5-FU as well as assayed their proliferation and cytotoxicity against the CT26 tumor cell line. We found that the absolute numbers of CD8 T-cells and NK cells were not influenced significantly after either one or three cycles of chemotherapy. However, after three cycles of 5-FU, proliferated CD8 T-cells were decreased, and CT26-specific cytotoxicity and IFN-γ secretion of spleen cells were impaired in vitro. After one cycle of 5-FU, there was a greater percentage of tumor infiltrating CD8 T-cells. In addition, more proliferated CD8 T-cells, enhanced tumor-specific cytotoxicity as well as IFN-γ secretion of spleen cells against CT26 in vitro were observed. Given the increased expression of immunosuppressive factors, such as PD-L1 and TGF-β, we assessed the effect of early introduction of immunotherapy in combination with chemotherapy. We found that mice treated with cytokine induced killer cells and PD-L1 monoclonal antibodies after one cycle of 5-FU had a better anti-tumor performance than those treated with chemotherapy or immunotherapy alone. These data suggest that a single cycle of 5-FU treatment promoted an anti-tumor immune response, whereas repeated chemotherapy

  12. Preliminary study on the evaluation of Langerhans cell histiocytosis using F-18-fluoro-deoxy-glucose PET/CT

    Institute of Scientific and Technical Information of China (English)

    Zhou Wenlan; Wu Hubing; Han Yanjiang; Wang Shaobo; Dong Ye; Wang Quanshi

    2014-01-01

    Background Limited number of studies have been reported regarding the utilization of F-18-fluoro-deoxy-glucose (F-18-FDG) positron emission tomography/computed tomography (F-18-FDG PET/CT) in Langerhans cell histiocytosis (LCH).The aim of this study was to assess the role of F-18-FDG PET/CT in the diagnosis and treatment of LCH.Methods Eight newly diagnosed and seven recurrent patients with LCH received F-18-FDG PET/CT scans.The diagnosis of LCH was established by pathology,multi-modality imaging,and clinical follow-up.Results F-18-FDG PET/CT was positive in 14 patients with 13 true positives and one false positive.All 45 LCH lesions were F-18-FDG avid including six small bone lesions <1.0 cm in diameter.The mean maximal standardized uptake value (SUVmax) was 7.13±4.91.F-18-FDG uptake showed no significant difference between newly diagnosed lesions vs recurrent lesions (SUVmax:6.50±2.97 vs.7.93±6.60,t=-0.901,P=0.376).Among 45 LCH lesions,68.9% (31/45) were found in bones and 31.1% (14/45) in soft tissue.The most commonly involved bones were the pelvis and vertebrae.There was no significant difference in F-18-FDG uptake between bone lesions vs.non-bone lesions (SUVmax:6.30±2.87 vs.8.97±7.58,t=1.277,P=0.221).In two patients,changes in F-18-FDG uptake on serial PET/CT scans reflected response of lesions to treatment.Conclusions The present study suggests that F-18-FDG PET/CT may be useful for diagnosis and assessing the treatment response of LCH.Because of the small sample size,further research is warranted to confirm our findings.

  13. Medulloblastoma in children: CT and MRI findings

    International Nuclear Information System (INIS)

    Tortori-Donati, P.; Fondelli, M.P.; Rossi, A.; Cama, A.; Caputo, L.; Andreussi, L.; Garre, M.L.

    1996-01-01

    Our purpose was to determine whether medulloblastoma (MB) shows specific neuroradiological features which may be employed in differential diagnosis from other common posterior cranial fossa tumours in childhood. Preoperative MRI was performed on 20 children with MB, and preoperative CT in 17 of them. All underwent surgery and histopathological diagnosis. There was a constant relationship between high density on CT and low signal on T1-weighted images. Signal behaviour on T2-weighted images and the degree of contrast enhancement were more variable. Most tumours arose in the midline, from the cerebellar vermis, involving the fourth ventricle, but hemisphere and extra-axial neoplasms were also seen. The combination of high density on CT and low signal on T1-weighted images is highly suggestive of MB and may assist preoperative differential diagnosis from other posterior cranial fossa tumours. (orig.). With 9 figs., 2 tabs

  14. The status of appendiceal CT in our hospital

    International Nuclear Information System (INIS)

    Honda, Yukiko; Nakanishi, Tadashi; Tagawa, Kohei; Akagi, Shinji; Kurisu, Yoshihiro; Ito, Katsuhide

    2006-01-01

    Images of 188 cases (112 males and 76 females; 5-88 years old, average 36) of patients with suspected appendicitis were retrospectively examined in the document (October 2003-July 2005). CT was conducted by 16-multidetector-row CT apparatus (MDCT) (Somatom Sensation Cardiac, Siemens) and evaluated the disease as positive, equivocal or negative. The number of positive diagnosis was 63, equivocal 5, and negative 120. Forty-four positive patients received the operation, 42 of whom were found to have appendicitis. Two out of 5 equivocal patients underwent the surgery and appendicitis was diagnosed in both. Ten negative patients received the operation through re-examination of their images, 6 of whom were found to have appendicitis. As above MDCT has improved the accuracy of diagnosis of acute appendicitis, indicating its usefulness in this field. (T.I.)

  15. Two-dimensional MRI at 1.5 and 0.5 T versus CT myelography in the diagnosis of cervical radiculopathy

    International Nuclear Information System (INIS)

    Bartlett, R.J.V.; Rowland Hill, C.A.; Devlin, R.; Gardiner, E.D.

    1996-01-01

    A prospective comparison was made of standard two-dimensional MRI sequences, at both high and midfield strength, with CT myelography in 23 patients with cervical spondylosis. MRI is adequate for assessment of cord compression, where high field strength is superior to midfield strength. MRI using 4-mm sections is inadequate for presurgical assessment of root compression. It remains to be proven whether thin-section white-CSF volume sequences or gadolinium-enhanced volume studies can replace CT myelography. (orig.). With 6 tabs

  16. Chondroitin sulfate iron colloid-enhanced MR imaging in patients with hepatocellular carcinoma. Comparison with CT during arterial portography

    Energy Technology Data Exchange (ETDEWEB)

    Kamba, Masayuki [Dept. of Radiology, Tottori Univ., Yonago (Japan); Suto, Y. [Dept. of Radiology, Tottori Univ., Yonago (Japan); Kato, T. [Dept. of Radiology, Tottori Univ., Yonago (Japan)

    1994-11-01

    Chondroitin sulfate iron colloid (CSIC) was used as an MR contrast agent for the detection of hepatocellular carcinoma (HCC). The findings of 25 surgically confirmed HCCs in 19 patients were retrospectively analyzed. T1-, T2- and proton density-weighted spin echo MR images were obtained before and after i.v. injection of 23.6 {mu}M Fe/kg of CSIC. Unenhanced and CSIC-enhanced MR images and images obtained by CT during arterial protography (CT-AP) were correlated with surgical pathology findings. The sensitivities of CSIC-enhanced and unenhanced MR imaging, and CT-AP were 92%, 80%, and 88%, respectively. No significant differences were noted. Portal flow abnormalities demonstrated by CT-AP did not affect the detection of HCC by CSIC-enhanced MR imaging. CSIC-enhancement at MR imaging was a disadvantage in the detection of lesions less than 1 cm in diameter. CSIC-enhanced MR imaging is a supplemental method for the detection of HCC. (orig.).

  17. Bakery products from irradiated and unirradiated eggs - detection of irradiation in a processed food

    International Nuclear Information System (INIS)

    Pfordt, J.; Grabowski, H.U. von

    1995-01-01

    The detection of radiation-specific degradation products in fat has become an established method which has successfully been applied to egg products. This study is making evident the detectability of irradiated eggs as an ingredient of specified processed foods. Tart layers were produced from both irradiated and non-irradiated liquid whole egg. When the fat components were isolated from the tart layers and investigated by GC/MS, the presence of irradiated eggs could clearly be shown. While the radiation-induced hydrocarbons and 2-alkylcyclobutanones could not be found in unirradiated samples, tart layers from irradiated eggs contained these substances. Especially for the hydrocarbons a satisfying correlation between radiation dose and concentration could be observed. The concentrations of radiation-induced compounds were generally lower in the tart layers than in the liquid egg samples they had been produced from. (orig.) [de

  18. Imaging fusion (SPECT/CT) in degenerative disease of spine

    International Nuclear Information System (INIS)

    Bernal, P.; Ucros, G.; Bermudez, S.; Ocampo, M.

    2007-01-01

    Full text: Objective: To determine the utility of Fusion Imaging SPECT/CT in degenerative pathology of the spine and to establish the impact of the use of fusion imaging in spinal pain due to degenerative changes of the spine. Materials and methods: 44 Patients (M=21, F=23) average age of 63 years and with degenerative pathology of spine were sent to Diagnosis Imaging department in FSFB. Bone scintigraphy (SPECT), CT of spine (cervical: 30%, Lumbar 70%) and fusion imaging were performed in all of them. Bone scintigraphy was carried out in a gamma camera Siemens Diacam double head attached to ESOFT computer. The images were acquired in matrix 128 x 128, 20 seg/imag, 64 images. CT of spine was performed same day or two days after in Helycoidal Siemens somatom emotion CT. The fusion was done in a Dicom workstation in sagital, axial and coronal reconstruction. The findings were evaluated by 2 Nuclear Medicine physicians and 2 radiologists of the staff of FSFB in an independent way. Results: Bone scan (SPECT) and CT of 44 patients were evaluated. CT showed facet joint osteoarthrities in 27 (61.3%) patients, uncovertebral joint arthrosis in 7 (15.9%), bulging disc in 9(20.4%), spinal nucleus lesion in 7(15.9%), osteophytes in 9 (20.4%), spinal foraminal stenosis in 7 (15.9%), spondylolysis/spondylolisthesis in 4 (9%). Bone scan showed facet joint osteoarthrities in 29 (65.9%), uncovertebral joint arthrosis in 4 (9%), osteophytes in 9 (20.4%) and normal 3 (6.8%). The imaging fusion showed coincidence findings (main lesion in CT with high uptake in scintigraphy) in 34 patients (77.2%) and no coincidence in 10 (22.8%). In 15 (34.09%) patients the fusion provided additional information. The analysis of the findings of CT and SPECT showed similar results in most of the cases and the fusion didn't provide additional information but it allowed to confirm the findings but when the findings didn't match where the CT showed several findings and SPECT only one area with high uptake

  19. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT

    International Nuclear Information System (INIS)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U.

    2012-01-01

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI vol values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 ± 2.5 vs. 11.4 ± 1.4, p < 0.001; 14.2 ± 3.7 vs. 16.1 ± 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 ± 201.1 vs. 849.8 ± 90.9, p < 0,001; 504.4 ± 134.4 vs. 471.5 ± 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 ± 35.8 vs. 155.5 ± 12.3 (p < 0.001), thorax 427.4 ± 44.5 vs. 388.3 ± 57.5 (p < 0.001), abdomen 520.3 ± 50.2 vs. 490.8 ± 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 ± 2.6 (4-row MDCT) and 24.1 ± 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  20. A study on CT attenuation and MR signal intensity of protein solution

    International Nuclear Information System (INIS)

    Kim, Joung Hae; Choi, Dae Seob; Kim, Soon; Lee, Hyeon Kyeong; Oh, Hyeon Hee; Kim, Seung Hyeon; Lee, Sung Woo; Chang, Kee Hyun; Chung, Jun Ho

    2001-01-01

    To correlate CT attenuation and MR signal intensity with concentration of protein solution. CT and MR examinations of a phantom containing bovine serum albumin solutions of various concentrations ranging from 0 to 55% were performed. CT Hounsfield units(HUs), MR signal intensities, and apparent diffusion coefficients (ADCs) of each albumin solution were measured, and CT HUs and MR signal intensities of the solutions were compared with those of cerebrospinal fluid (CSF), white matter, and cortical gray matter. CT HU increased gradually with increasing albumin concentration. On T1-weighted images(T1WI), signal intensity increased with increasing albumin concentrations of up to 35% but then decreased. On T2-weighted images(T2Wl), gradually decreasing signal intensity and increasing albumin concentration were observed Fluid-attenuated inversion recovery (FLAIR) and diffusion-weighted images (DWls) showed that signal intensity peaked at a concentration of 10% and then gradually decreased. The ADC of the solution gradually decreased as concentration increased. Compared with those of normal brain structures, the CT HUs of solutions at concentrations of over 20% were higher than those of white and gray matter. At T1WI, the signal intensities of 10-45% solutions were similar to or higher than that of the gray matter. At T2Wl, the signal intensities of solutions above 25, 35, and 40% were lower than those of CSF, gray matter, and white matter, respectively. FLAIR images showed that the signal intensities of 5-35% solutions were higher than that of gray matter. The CT attenuation of albumin solution increased gradually with increasing concentration. MR signal intensities peaked at 35% concentration on T1WI and at 10% on FLAIR and DW images, respectively, and then gradually decreased. T2Wl and ADC map images showed gradually decreasing signal intensity and ADC as albumin concentration increased

  1. Evaluation of Bone Metastasis from Hepatocellular Carcinoma Using {sup 18F} FDG PET/CT and {sup 99mT}c HDP Bone Scintigraphy: Characteristics of Soft Tissue Formation

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo Jung; Choi, Yun Jung; Kim, Hyun Jeong; Jeong, Youg Hyu; Cho, Arthur; Lee, Jae Hoon; Yun, Mijin; Choi, Hye Jin; Lee, Jong Doo; Kang, Won Jun [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-09-15

    Bone metastasis from hepatocellular carcinoma (HCC) can present with soft tissue formation, resulting in oncologic emergency. Contrast enhanced FDG PET/CT and bone scintigraphy were compared to evaluate characteristics of bone metastases with of without soft tissue formation from HCC. of 4,151 patients with HCC, 263 patients had bone metastases. Eighty five patients with bone metastasis from HCC underwent contrast enhanced FDG PET/CT. Fifty four of the enrolled subjects had recent {sup 99mT}c HDP bone scintigraphy available for comparison. Metastatic bone lesions were identified with visual inspection on FDG PET/CT, and maximum standardized uptake value (SUVmax) was used for the quantitative analysis. Confirmation of bone metastasis was based on histopathology, combined imaging modalities, or serial follow up studies. Forty seven patients (55%) presented with soft tissue formation, while the remaining 38 patients presented without soft tissue formation. Frequent sites of bone metastases from HCC were the spine (39%), pelvis (19%), and rib cage (14%). The soft tissue formation group had more frequent bone pain (77 vs. 37%, p<0.0001), higher SUVmax (6.02 vs. 3.52, p<0.007), and higher incidence of photon defect in bone scintigraphy (75 vs. 0%) compared to the non soft tissue formation group. FDG PET/CT had higher detection rate for bone metastasis than bone scintigraphy both in lesion based analysis (98 vs. 53%, p=0.0015) and in patient based analysis (100 vs. 80%, p<0.001). Bone metastasis from HCC showed a high incidence of soft tissue formation requiring emergency treatment. Although the characteristic findings for soft tissue formation such as photon defect in bone scintigraphy are helpful in detection, overall detectability of bone metastasis is higher in FDG PET/CT. Contrast enhanced PET/CT will be useful in finding and delineating soft tissue forming bone metastasis from HCC.

  2. The importance of -460 C/T and +405 G/C single nucleotide polymorphisms to the function of vascular endothelial growth factor A in colorectal cancer

    DEFF Research Database (Denmark)

    Hansen, Torben F; Spindler, Karen-Lise G; Lorentzen, Karen A

    2010-01-01

    collected from 113 patients surgically resected for colorectal cancer. SNPs were analysed from genomic DNA by PCR, the VEGF-A gene expression analysis was performed by RT-PCR and protein analysis by ELISA. RESULTS: The T-allele in the -460 C/T SNP and the C-allele in the +405 G/C SNP were associated...... with significantly lower VEGF-A protein levels in normal colorectal tissue. There were no differences in protein levels in the malignant tissue according to genotypes. No differences were observed at the gene expression levels either. CONCLUSION: The results indicate that the two SNPs have a functional influence......PURPOSE: The present study investigated the functional influence of the single nucleotide polymorphisms (SNPs) -460 C/T and +405 G/C at vascular endothelial growth factor A (VEGF-A), mRNA and protein levels in colorectal cancer (CRC) and normal colorectal tissue. METHODS: Blood and tissue were...

  3. CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

    International Nuclear Information System (INIS)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2015-01-01

    Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D L (0) and its rise-to-the-equilibrium curve H(L) = D L (0)/D eq from computed tomography (CT) scanning, where D eq is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessed H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm 3 thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E in /E or E out /E) on the phantom central and peripheral axes, where E = LD eq was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose ratios changed with beam aperture and

  4. CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xinhua; Zhang, Da; Liu, Bob, E-mail: bliu7@mgh.harvard.edu [Division of Diagnostic Imaging Physics and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States)

    2015-06-15

    Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D{sub L}(0) and its rise-to-the-equilibrium curve H(L) = D{sub L}(0)/D{sub eq} from computed tomography (CT) scanning, where D{sub eq} is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessed H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm{sup 3} thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E{sub in}/E or E{sub out}/E) on the phantom central and peripheral axes, where E = LD{sub eq} was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose

  5. Mediastinal lymphadenopathy in congestive heart failure: a sequential CT evaluation with clinical and echocardiographic correlations

    International Nuclear Information System (INIS)

    Chabbert, Valerie; Canevet, Guillaume; Otal, Philippe; Joffre, Francis; Baixas, Cecile; Galinier, Michel; Deken, Valerie; Duhamel, Alain; Remy, Jacques; Remy-Jardin, Martine

    2004-01-01

    The aim of this study was to evaluate the frequency and evolution after treatment of mediastinal lymphadenopathy associated with congestive left heart failure on CT scans in correlation with clinical and echocardiographic findings. Thirty-one consecutive patients with subacute left heart failure underwent a clinical evaluation using the NYHA classification, a CT examination, and transthoracic echocardiography at the time of initial presentation (T1). After initiation of medical treatment (T2), follow-up CT scans were systematically obtained together with a clinical evaluation. At T1, all patients showed severe (type III: n=12, 39%; type IV: n=12, 39%) to moderate (type I, n=1, 3%; type II, n=6, 19%) dyspnea with a mean ejection fraction of 39% (range 22-74%). On initial CT scans, enlarged mediastinal lymph nodes were seen in 13 patients (42%) with blurred contours in 5 patients (16%) and hazy mediastinal fat in 1 patient (3%). Significant decrease in the size of lymphadenopathy was observed between T1 and T2 (T1, n=13, 42% vs T2, n=10, 32%; p<0.05) with a concurrent decrease in the severity of dyspnea (grade III-IV dyspnea at T1, n=24, 78% vs grade I-II dyspnea at T2, n=26, 83.5%). Patients with enlarged lymph nodes at T1 showed: (a) a significantly lower ejection fraction at echocardiography than those without lymphadenopathy (mean±SD value: 34±12.9 vs 43±13.8%; p=0.04); (b) a significantly larger diameter of the right superior pulmonary vein (mean±SD value: 17±2.75 vs 14±3.9 mm; p=0.04); and (c) a higher frequency of abnormal peribronchovascular thickening (n=5 vs n=1; p=0.06). Mediastinal lymphadenopathy associated with subacute left heart failure was observed in 13 patients (42%), showing regression after initiation of treatment in 8 of 13 patients (62%). (orig.)

  6. Mediastinal lymphadenopathy in congestive heart failure: a sequential CT evaluation with clinical and echocardiographic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Chabbert, Valerie; Canevet, Guillaume; Otal, Philippe; Joffre, Francis [Department of Radiology, University of Toulouse, Avenue Jean-Poulhes, 31403, Toulouse (France); Baixas, Cecile; Galinier, Michel [Department of Cardiology, University of Toulouse, Avenue Jean-Poulhes, 31403, Toulouse (France); Deken, Valerie; Duhamel, Alain [Department of Medical Statistics, University of Lille, Place de Verdun, 59037, Lille Cedex (France); Remy, Jacques; Remy-Jardin, Martine [Department of Radiology, Hospital Calmette, University Center of Lille, Boulevard Jules Leclerc, 59037, Lille Cedex (France)

    2004-05-01

    The aim of this study was to evaluate the frequency and evolution after treatment of mediastinal lymphadenopathy associated with congestive left heart failure on CT scans in correlation with clinical and echocardiographic findings. Thirty-one consecutive patients with subacute left heart failure underwent a clinical evaluation using the NYHA classification, a CT examination, and transthoracic echocardiography at the time of initial presentation (T1). After initiation of medical treatment (T2), follow-up CT scans were systematically obtained together with a clinical evaluation. At T1, all patients showed severe (type III: n=12, 39%; type IV: n=12, 39%) to moderate (type I, n=1, 3%; type II, n=6, 19%) dyspnea with a mean ejection fraction of 39% (range 22-74%). On initial CT scans, enlarged mediastinal lymph nodes were seen in 13 patients (42%) with blurred contours in 5 patients (16%) and hazy mediastinal fat in 1 patient (3%). Significant decrease in the size of lymphadenopathy was observed between T1 and T2 (T1, n=13, 42% vs T2, n=10, 32%; p<0.05) with a concurrent decrease in the severity of dyspnea (grade III-IV dyspnea at T1, n=24, 78% vs grade I-II dyspnea at T2, n=26, 83.5%). Patients with enlarged lymph nodes at T1 showed: (a) a significantly lower ejection fraction at echocardiography than those without lymphadenopathy (mean{+-}SD value: 34{+-}12.9 vs 43{+-}13.8%; p=0.04); (b) a significantly larger diameter of the right superior pulmonary vein (mean{+-}SD value: 17{+-}2.75 vs 14{+-}3.9 mm; p=0.04); and (c) a higher frequency of abnormal peribronchovascular thickening (n=5 vs n=1; p=0.06). Mediastinal lymphadenopathy associated with subacute left heart failure was observed in 13 patients (42%), showing regression after initiation of treatment in 8 of 13 patients (62%). (orig.)

  7. Structural conservation, variability, and immunogenicity of the T6 backbone pilin of serotype M6 Streptococcus pyogenes.

    Science.gov (United States)

    Young, Paul G; Moreland, Nicole J; Loh, Jacelyn M; Bell, Anita; Atatoa Carr, Polly; Proft, Thomas; Baker, Edward N

    2014-07-01

    Group A streptococcus (GAS; Streptococcus pyogenes) is a Gram-positive human pathogen that causes a broad range of diseases ranging from acute pharyngitis to the poststreptococcal sequelae of acute rheumatic fever. GAS pili are highly diverse, long protein polymers that extend from the cell surface. They have multiple roles in infection and are promising candidates for vaccine development. This study describes the structure of the T6 backbone pilin (BP; Lancefield T-antigen) from the important M6 serotype. The structure reveals a modular arrangement of three tandem immunoglobulin-like domains, two with internal isopeptide bonds. The T6 pilin lysine, essential for polymerization, is located in a novel VAKS motif that is structurally homologous to the canonical YPKN pilin lysine in other three- and four-domain Gram-positive pilins. The T6 structure also highlights a conserved pilin core whose surface is decorated with highly variable loops and extensions. Comparison to other Gram-positive BPs shows that many of the largest variable extensions are found in conserved locations. Studies with sera from patients diagnosed with GAS-associated acute rheumatic fever showed that each of the three T6 domains, and the largest of the variable extensions (V8), are targeted by IgG during infection in vivo. Although the GAS BP show large variations in size and sequence, the modular nature of the pilus proteins revealed by the T6 structure may aid the future design of a pilus-based vaccine. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  8. Hepatic sinusoidal obstruction syndrome caused by herbal medicine: CT and MRI features

    International Nuclear Information System (INIS)

    Zhou, Hua; Lou, Hai Yan; Wang, Yi Xiang J.; Xu, Xiao Jun; Zhang, Min Ming

    2014-01-01

    To describe the CT and MRI features of hepatic sinusoidal obstruction syndrome (HSOS) caused by herbal medicine Gynura segetum. The CT and MRI features of 16 consecutive Gynura segetum induced HSOS cases (12 men, 4 women) were analyzed. Eight patients had CT; three patients had MRI, and the remaining five patients had both CT and MRI examinations. Based on their clinical presentations and outcomes, the patients were classified into three categories: mild, moderate, and severe. The severity of the disease was also evaluated radiologically based on the abnormal hepatic patchy enhancement in post-contrast CT or MRI images. Ascites, patchy liver enhancement, and main right hepatic vein narrowing or occlusion were present in all 16 cases. Hepatomegaly and gallbladder wall thickening were present in 14 cases (87.5%, 14/16). Periportal high intensity on T2-weighted images was present in 6 cases (75%, 6/8). Normal liver parenchymal enhancement surrounding the main hepatic vein forming a clover-like sign was observed in 4 cases (25%, 4/16). The extent of patchy liver enhancement was statistically associated with clinical severity classification (kappa = 0.565). Ascites, patchy liver enhancement, and the main hepatic veins narrowing were the most frequent signs of herbal medicine induced HSOS. The grade of abnormal patchy liver enhancement was associated with the clinical severity.

  9. Hepatic sinusoidal obstruction syndrome caused by herbal medicine: CT and MRI features

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Hua; Lou, Hai Yan [Dept. of Radiology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou (China); Wang, Yi Xiang J. [Dept. of Radiology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou (China); Xu, Xiao Jun; Zhang, Min Ming [Dept. of Radiology, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou (China)

    2014-04-15

    To describe the CT and MRI features of hepatic sinusoidal obstruction syndrome (HSOS) caused by herbal medicine Gynura segetum. The CT and MRI features of 16 consecutive Gynura segetum induced HSOS cases (12 men, 4 women) were analyzed. Eight patients had CT; three patients had MRI, and the remaining five patients had both CT and MRI examinations. Based on their clinical presentations and outcomes, the patients were classified into three categories: mild, moderate, and severe. The severity of the disease was also evaluated radiologically based on the abnormal hepatic patchy enhancement in post-contrast CT or MRI images. Ascites, patchy liver enhancement, and main right hepatic vein narrowing or occlusion were present in all 16 cases. Hepatomegaly and gallbladder wall thickening were present in 14 cases (87.5%, 14/16). Periportal high intensity on T2-weighted images was present in 6 cases (75%, 6/8). Normal liver parenchymal enhancement surrounding the main hepatic vein forming a clover-like sign was observed in 4 cases (25%, 4/16). The extent of patchy liver enhancement was statistically associated with clinical severity classification (kappa = 0.565). Ascites, patchy liver enhancement, and the main hepatic veins narrowing were the most frequent signs of herbal medicine induced HSOS. The grade of abnormal patchy liver enhancement was associated with the clinical severity.

  10. MR imaging and CT in osteoarthritis of the lumbar facet joints

    International Nuclear Information System (INIS)

    Weishaupt, D.; Zanetti, M.; Hodler, J.; Boos, N.

    1999-01-01

    Objective. To test the agreement between MR imaging and CT in the assessment of osteoarthritis of the lumbar facet joints, and thus to provide data about the need for an additional CT scan in the presence of an MR examination. Design and patients. Using a four-point scale, two musculoskeletal radiologists independently graded the severity of osteoarthritis of 308 lumbar facet joints on axial T2-weighted and on sagittal T1- and T2-weighted turbo-spin-echo images and separately on the corresponding axial CT scans. Kappa statistics and percentage agreement were calculated. Results. The weighted kappa coefficients for MR imaging versus CT were 0.61 and 0.49 for readers 1 and 2, respectively. The weighted kappa coefficients for interobserver agreement were 0.41 for MR imaging and 0.60 for CT, respectively. There was agreement within one grade between MR and CT images in 95% of cases for reader 1, and in 97% of cases for reader 2. Conclusion. With regard to osteoarthritis of the lumbar facet joints there is moderate to good agreement between MR imaging and CT. When differences of one grade are disregarded agreement is even excellent. Therefore, in the presence of an MR examination CT is not required for the assessment of facet joint degeneration. (orig.)

  11. The MMP-9 -1562 C/T polymorphism in the presence of metabolic syndrome increases the risk of clinical events in patients with coronary artery disease.

    Directory of Open Access Journals (Sweden)

    Trine B Opstad

    Full Text Available Elevated levels of matrix metalloproteinase (MMP-9 have been associated with the metabolic syndrome (MetS and cardiovascular events. The MMP-9 -1562 C/T polymorphism has furthermore been shown as a risk factor for coronary artery disease (CAD. The non-favourable cardiometabolic state in MetS may increase the risk. We aimed to investigate the influence of MMP-9 -1562 C/T polymorphism in subjects with CAD and MetS.Patients (n = 1000 with verified CAD stratified in Mets +/- (n = 244/756, were analyzed for the MMP-9 -1562 C/T polymorphism and related to clinical events after 2 years follow-up. Serum levels of total MMP-9 and tissue inhibitor of matrix metalloproteinases (TIMP-1 were analyzed in all, whereas MMP-9 activity, extracellular matrix metalloproteinase inducer (EMMPRIN, and expression of the two genes were analyzed in a subset of 240 randomly selected patients.Totally, 106 clinical endpoints were recorded. In MetS; the T-allele associated with 5.5 fold increase in event rate (p<0.0001, increased with number of MetS components, a 117% increase in total MMP-9 levels (TT homozygous, p = 0.05, significantly higher total- and endogenous active MMP-9 and TIMP-1 levels (p<0.01 all, and EMMPRIN was inversely correlated with pro- and endogenous active MMP-9 (p<0.05, both. In non-MetS; the T-allele was not associated with new events, nor higher MMP-9 levels. EMMPRIN was significantly correlated with total MMP-9 and TIMP-1 (p<0.01, both and the two genes were inter-correlated (p<0.001.In CAD patients with MetS, the MMP-9 T-allele increased the risk of clinical events, probably mediated through elevated MMP-9 levels and altered MMP-9 regulation.

  12. Fast T1- and T2-weighted pulmonary MR-imaging in patients with bronchial carcinoma

    International Nuclear Information System (INIS)

    Both, M.; Schultze, J.; Reuter, M.; Bewig, B.; Hubner, R.; Bobis, I.; Noth, R.; Heller, M.; Biederer, J.

    2005-01-01

    Purpose: A prospective study to evaluate the diagnostic potential and limitations of three fast MRI sequences in patients with bronchial carcinoma based on the comparison with spiral CT. Material and methods: Three fast chest MRI sequences from 20 patients with central or peripheral bronchial carcinoma were evaluated by two observers for relation of tumour to adjacent structures, lymph node enlargement, additional pulmonary lesions and artefacts. The information from MR-imaging was compared with the results from spiral CT. MRI comprised a T1-3D-GRE breath-hold examination ('VIBE', TR/TE 4.5/1.9 ms, flip-angle 12 deg., matrix 502 x 512, 2.5 mm coronal slices), a breath-hold, T2-HASTE sequence (TR/TE 2000/43 ms, matrix 192 x 256, 10 mm coronal slices) and a respiration-triggered T2-TSE sequence (TR/TE 3000-6000/120 ms, matrix 270 x 512, 6 mm transverse slices). The FOV was adapted individually (380-480 mm). Results: The presence of the primary bronchial carcinoma and infiltration of thoracic structures by tumour tissue could be demonstrated by all sequences. VIBE sequence was more suitable for detecting small pulmonary nodules than the other MRI examinations, but compared to CT still 20% of these lesions were missed. Contrary to VIBE and T2-weighted TSE scans, HASTE sequence was limited in imaging mediastinal lymph nodes due to missing relevant findings in 2/20 patients. HASTE images significantly provided the lowest rate of artefacts in imaging lung parenchyma (P < 0.001 in peripheral parenchyma), but spatial resolution was limited in this sequence. Concerning the differentiation between tumour and adjacent atelectasis (n = 8), T2-weighted TSE imaging was superior to CT and VIBE in all cases and to HASTE sequence in 4/8 patients. Conclusion: The combination of VIBE and HASTE sequence allows for an adequate imaging of thoracic processes in patients with bronchial carcinoma, limited only in visualizing small pulmonary nodules. To obtain more detail resolution and to

  13. Interleukin-6 Receptor rs7529229 T/C Polymorphism Is Associated with Left Main Coronary Artery Disease Phenotype in a Chinese Population

    Directory of Open Access Journals (Sweden)

    Feng He

    2014-04-01

    Full Text Available Left main coronary artery disease (LMCAD is a particular severe phenotype of coronary artery disease (CAD and heritability. Interleukin (IL may play important roles in the pathogenesis of CAD. Although several single nucleotide polymorphisms (SNPs identified in IL related genes have been evaluated for their roles in inflammatory diseases and CAD predisposition, the investigations between genetic variants and CAD phenotype are limited. We hypothesized that some of these gene SNPs may contribute to LMCAD phenotype susceptibility compared with more peripheral coronary artery disease (MPCAD. In a hospital-based case-only study, we studied IL-1A rs1800587 C/T, IL-1B rs16944 G/A, IL-6 rs1800796 C/G, IL-6R rs7529229 T/C, IL-8 rs4073 T/A, IL-10 rs1800872 A/C, and IL-10 rs1800896 A/G SNPs in 402 LMCAD patients and 804 MPCAD patients in a Chinese population. Genotyping was done using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS and ligation detection reaction (LDR method. When the IL-6R rs7529229 TT homozygote genotype was used as the reference group, the CC or TC/CC genotypes were associated with the increased risk for LMCAD (CC vs. TT, adjusted odds ratio(OR = 1.46, 95% confidence interval (CI = 1.02–2.11, p = 0.042; CC + TC vs. TT, adjusted OR = 1.31, 95% CI = 1.02–1.69, p = 0.037. None of the other six SNPs achieved any significant differences between LMCAD and MPCAD. The present study suggests that IL-6R rs7529229 T/C functional SNP may contribute to the risk of LMCAD in a Chinese population. However, our results were limited. Validation by a larger study from a more diverse ethnic population is needed.

  14. Differential Role of the T6SS in Acinetobacter baumannii Virulence

    Science.gov (United States)

    Foucault-Grunenwald, Marie-Laure; Borges, Vitor; Charpentier, Xavier; Limansky, Adriana S.; Gomes, João Paulo; Viale, Alejandro M.; Salcedo, Suzana P.

    2015-01-01

    Gram-negative bacteria, such as Acinetobacter baumannii, are an increasing burden in hospitals worldwide with an alarming spread of multi-drug resistant (MDR) strains. Herein, we compared a type strain (ATCC17978), a non-clinical isolate (DSM30011) and MDR strains of A. baumannii implicated in hospital outbreaks (Ab242, Ab244 and Ab825), revealing distinct patterns of type VI secretion system (T6SS) functionality. The T6SS genomic locus is present and was actively transcribed in all of the above strains. However, only the A. baumannii DSM30011 strain was capable of killing Escherichia coli in a T6SS-dependent manner, unlike the clinical isolates, which failed to display an active T6SS in vitro. In addition, DSM30011 was able to outcompete ATCC17978 as well as Pseudomonas aeruginosa and Klebsiella pneumoniae, bacterial pathogens relevant in mixed nosocomial infections. Finally, we found that the T6SS of DSM30011 is required for host colonization of the model organism Galleria mellonella suggesting that this system could play an important role in A. baumannii virulence in a strain-specific manner. PMID:26401654

  15. Differential Role of the T6SS in Acinetobacter baumannii Virulence.

    Directory of Open Access Journals (Sweden)

    Guillermo D Repizo

    Full Text Available Gram-negative bacteria, such as Acinetobacter baumannii, are an increasing burden in hospitals worldwide with an alarming spread of multi-drug resistant (MDR strains. Herein, we compared a type strain (ATCC17978, a non-clinical isolate (DSM30011 and MDR strains of A. baumannii implicated in hospital outbreaks (Ab242, Ab244 and Ab825, revealing distinct patterns of type VI secretion system (T6SS functionality. The T6SS genomic locus is present and was actively transcribed in all of the above strains. However, only the A. baumannii DSM30011 strain was capable of killing Escherichia coli in a T6SS-dependent manner, unlike the clinical isolates, which failed to display an active T6SS in vitro. In addition, DSM30011 was able to outcompete ATCC17978 as well as Pseudomonas aeruginosa and Klebsiella pneumoniae, bacterial pathogens relevant in mixed nosocomial infections. Finally, we found that the T6SS of DSM30011 is required for host colonization of the model organism Galleria mellonella suggesting that this system could play an important role in A. baumannii virulence in a strain-specific manner.

  16. Interleukin-10 -592C/A, -819C/T and -1082A/G Polymorphisms with Risk of Type 2 Diabetes Mellitus: A HuGE Review and Meta-analysis.

    Directory of Open Access Journals (Sweden)

    Yanyin Hua

    Full Text Available Several studies have been conducted in recent years to evaluate the risk of type 2 diabetes mellitus (T2DM and polymorphisms of interleukin (IL-10. However, the results remain conflicting rather than conclusive. This meta-analysis aimed to summarize the current evidence from case-control studies that evaluated this association.We carried out a search in Medline, EMBASE, and the Chinese National Knowledge Infrastructure (CNKI database for relevant studies. Data were extracted using a standardized form and pooled odds ratios (ORs with 95% confidence intervals (CIs were calculated to assess the strength of the association.10 studies were included in our meta-analysis and systemic review. Our meta-analysis indicated that IL-10 -1082A/G polymorphism was associated with the risk of T2DM (GA vs. AA: OR = 1.21, 95% CI = 1.03-1.14; GA/GG vs. AA: OR = 1.22, 95% CI = 1.05-1.41, whereas there was no association between IL-10 -592C/A (CC/CA vs. AA: OR = 1.07, 95% CI = 0.59-1.93 or -819C/T (CC/CT vs. TT: OR = 0.93, 95% CI = 0.49-1.75 polymorphism and T2DM risk was found in our study.This meta-analysis provides strong evidence that IL-10 -1082A/G polymorphism associated with risk of T2DM. However, no association of the IL-10 -592C/A or -819C/T polymorphism with T2DM risk was found. Additional well-designed large studies were required for the validation of our results.

  17. Phantom study for the systemic performance of Gemini PET/CT

    International Nuclear Information System (INIS)

    Feng Yanlin; He Xiaohong; Huang Kemin; Yu Fengwen; Liu Dejun; Yuan Jianwei; Yuan Baihong; Su Shaodi

    2005-01-01

    Objective: To develop the methods and parameters for evaluating the systemic performance of Gemini PET/CT. Methods: The spatial resolution, standardized uptake value (SUV), uniformity and accuracy of image registration were selected as the evaluating indexes. The Jaszczak phantom with smaller inserts was filled with 18 F-fluorodeoxyglucose (FDG) solution and imaged with whole body and brain imaging modes, respectively, to evaluate the spatial resolution of the PET/CT; a Philips hollow phantom was filled with 18 F-FDG solution and imaged for calculating the SUV and the uniformity parameters; four 22 Na solid sources were put under the pad of the patient table and imaged synchronously with the patient's data acquisition to evaluate the accuracy of the PET and CT image fusion. Results: The rods of the diameter of 6.4 mm of both the hot and cold inserts were observed with whole body imaging mode, and rods of the diameters of 4.8 mm of both the hot and cold inserts were observed with brain imaging mode. The SUV with X-ray CT attenuation correction (CTAC) was 0.92 ± 0.24, and was 0.99±0.26 with 137 Cs attenuation correction (CsAC), and t=-1.327, P>0.05 between the two groups. The uniformity of the images with both CTAC and CsAC was very nice, no artifacts were seen either. The maximum pixel counts was 3790, the minimum was 1434, the average was 2581.23 and the standard deviation was 728.39 with CTAC; and were 4218, 1073, 2758.19 and 838.79 with CsAC correspondingly, and t=-1.069, P>0.05 between the two groups. The images of PET and CT were registrated better, and also no diversity was detected on the fusion images. Conclusions: These methods and parameters might be used to evaluate the systemic performance of the PET/CT, and could also be used as the supplementary items for the acceptance test and daily quality assurance of the PET/CT. (authors)

  18. [Evaluations of newborn screening program performance and enzymatic diagnosis of glucose-6-phosphate dehydrogenase deficiency in Guangzhou].

    Science.gov (United States)

    Tang, F; Huang, Y L; Jiang, X; Jia, X F; Li, B; Feng, Y; Chen, Q Y; Tang, C F

    2018-05-02

    Objective: To reveal the molecular epidemiologic characteristics of glucose-6-phosphate dehydrogenase (G6PD) gene and to evaluate based on the genetic analysis the newborn screening program performance and enzymatic diagnosis of G6PD deficiency in Guangzhou. Methods: G6PD enzyme activities were measured by quantitative fluorescence assay in dry blood spots of 16 319 newborns(8 725 males, 7 594 females) 3-7 days after birth in Guangzhou Newborn Center. They were born in Guangzhou form Oct. 1 to 20, 2016. The cutoff value of G6PD was less than 2.6 U/g Hb in dry blood spots. G6PD deficiency was diagnosed when G6PDblood cells. Genetic analysis of G6PD gene was performed on the dry blood spot samples of 823 newborns (including positive 346, negative 477)with various levels of G6PD enzyme activities through fluorescence PCR melting curve analysis(FMCA) to detect 15 kinds of mutations reported to be common among Chinese.G6PD gene Sanger sequency was performed in seven highly suspicious patients with negative results by FMCA. Results: (1) Using the cutoff value of G6PDT, c.551C>T, c.835A>T hemizygote were found in 3 male's samples, respectively. (3) The estimated prevalence of harboring mutation was 6.0% in males and 13.5% in females according to rates of mutation in samples with various levels of G6PD enzyme activities. Six common mutations were c.1388G>A、c.1376G>T, c.95A> G, c.871G>A, c.1024C>T, c.392G>T, accounting for 95.5% of detected alleles .(4) based on results of G6PD gene analysis, the newborn scereening of G6PD deficiency with cutoff value G6PDblood cells were 95.5%, 97.2%, respectively. Conclusions: The prevalence of G6PD deficiency in males was 6.0% in Guangzhou. Six mutations c.1388G>A, c.1376G>T, c.95A>G, c.871G>A, c.1024C>T, c.392G>T accounted for 95.5%. The cutoff value of G6PD<2.6 U/g Hb innewborn screening program and the criteria of biochemical diagnosis could accurately identify G6PD deficiency . Combined with biochemical and molecular analysis will

  19. Sugar-induced cephalic-phase insulin release is mediated by a T1r2+T1r3-independent taste transduction pathway in mice.

    Science.gov (United States)

    Glendinning, John I; Stano, Sarah; Holter, Marlena; Azenkot, Tali; Goldman, Olivia; Margolskee, Robert F; Vasselli, Joseph R; Sclafani, Anthony

    2015-09-01

    Sensory stimulation from foods elicits cephalic phase responses, which facilitate digestion and nutrient assimilation. One such response, cephalic-phase insulin release (CPIR), enhances glucose tolerance. Little is known about the chemosensory mechanisms that activate CPIR. We studied the contribution of the sweet taste receptor (T1r2+T1r3) to sugar-induced CPIR in C57BL/6 (B6) and T1r3 knockout (KO) mice. First, we measured insulin release and glucose tolerance following oral (i.e., normal ingestion) or intragastric (IG) administration of 2.8 M glucose. Both groups of mice exhibited a CPIR following oral but not IG administration, and this CPIR improved glucose tolerance. Second, we examined the specificity of CPIR. Both mouse groups exhibited a CPIR following oral administration of 1 M glucose and 1 M sucrose but not 1 M fructose or water alone. Third, we studied behavioral attraction to the same three sugar solutions in short-term acceptability tests. B6 mice licked more avidly for the sugar solutions than for water, whereas T1r3 KO mice licked no more for the sugar solutions than for water. Finally, we examined chorda tympani (CT) nerve responses to each of the sugars. Both mouse groups exhibited CT nerve responses to the sugars, although those of B6 mice were stronger. We propose that mice possess two taste transduction pathways for sugars. One mediates behavioral attraction to sugars and requires an intact T1r2+T1r3. The other mediates CPIR but does not require an intact T1r2+T1r3. If the latter taste transduction pathway exists in humans, it should provide opportunities for the development of new treatments for controlling blood sugar. Copyright © 2015 the American Physiological Society.

  20. Effect of helium pressure on the response of unirradiated UO2 subjected to thermal transients

    International Nuclear Information System (INIS)

    Fenske, G.R.; Chapello, P.M.; Emerson, J.E.; Poeppel, R.B.

    1983-01-01

    The effect of helium pressure on the transient response of unirradiated depleted UO 2 subjected to simulated hypothetical loss-of-flow accidents in a gas-cooled fast reactor was examined by use of the direct electrical heating technique. Transient tests were performed at pressures ranging from 7 to 10 X 10 5 Pa(7 to 10 atm) to 7 to 8 MPa (70 to 80 atm) on radially restrained and unrestrained fuel segments. The average heating rates ranged from about17 to 240 J/g x s. The results indicate that while the mechanical integrity of the fuel segment was independent of the test pressure, the rapid ejection of molten fuel from pellet interfaces of unrestrained fuel, observed at the lower pressures, was delayed or suppressed at the higher pressures

  1. Report of questionnaire concerning the conditions and exposure doses at thoracoabdominal radiography and CT

    International Nuclear Information System (INIS)

    2009-01-01

    Japan Association of Radiological Technologists, at 2 years after its presentation of the Guideline for Medical Radiation Exposure (2006), made a questionnaire in the title on its homepage on Nov. 6-Dec. 5, 2008, and this paper is its report. The questionnaire asked the conditions and exposure doses at thoracoabdominal radiography and CT: in the former, asked were conditions like the machine/detector, tube voltage, filter, incident angle, entrance plane dose (EPD) (mGy) etc., and 237 facilities including 56 public hospitals and 15 universities answered. EPD calculated by numerical dose determination was found to be 0.22 and 0.76 mGy at the frontal and lateral thoracic projection, respectively, which were less than the upper limit defined in International Atomic Energy Agency (IAEA) guidance (0.4 and 1.5 mGy). However, doses in 6 and 2.6% of facilities at the respective projection exceeded the IAEA levels. EPD at the frontal abdominal projection calculated was 2.22 mGy, and all facilities met with the IAEA demand level (<10 mGy). In the CT questionnaire, conditions asked were the machine manufacturer/brand, scanning mode and range, tube voltage, rotation time, beam width and pitch, slice width, CTDIvol (CT Dose Index weighted/pitch) (mGy) and so on, which 212 facilities involving 58 public hospitals and 14 universities answered. CTDIvol was found to be 91.7 mGy at head CT which greatly exceeded the maximal levels of International Commission of Radiological Protection (ICRP), IAEA and the Association (60, 50 and 65 mGy, respectively). CTDIvol at thoracic CT was 15.2 mGy (no standard upper limit at present), and at abdominal CT, 20.0 mGy (the same as the Association level). The latter suggested the suitable dose setting at this CT. Thus the problem at head CT was much highlighted here. (K.T.)

  2. The UCP2 -866G/A, Ala55Val and UCP3 -55C/T polymorphisms are associated with premature coronary artery disease and cardiovascular risk factors in Mexican population.

    Science.gov (United States)

    Gamboa, Ricardo; Huesca-Gómez, Claudia; López-Pérez, Vanessa; Posadas-Sánchez, Rosalinda; Cardoso-Saldaña, Guillermo; Medina-Urrutia, Aida; Juárez-Rojas, Juan Gabriel; Soto, María Elena; Posadas-Romero, Carlos; Vargas-Alarcón, Gilberto

    2018-05-21

    We examined the role of UCP gene polymorphisms as susceptibility markers for premature coronary artery disease (pCAD). The UCP2 Ala55Val (C/T rs660339), UCP2 -866G/A (rs659366), and UCP3 -55C/T (rs1800849) polymorphisms were genotyped in 948 patients with pCAD, and 763 controls. The distribution of the UCP2 A55V (C/T rs660339) and UCP3 -55 (rs1800849) was similar in patients and controls. However, under a recessive model, the UCP2 -866 (rs659366) A allele was associated with increased risk of developing pCAD (OR = 1.43, Pc = 0.003). On the other hand, patients with pCAD and UCP2 A55V (rs660339) TT showed high levels of visceral abdominal fat (VAF) (Pc = 0.002), low levels of subcutaneous abdominal fat (SAF) (Pc = 0.001) and high VAT/SAT ratio (Pc cardiovascular risk factors.

  3. Properties of unirradiated fuel element graphites H-451 and SO818. [Bulk density, tensile properties, thermal expansion, thermal conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Engle, G.B.; Johnson, W.R.

    1976-10-08

    Nuclear graphites H-451, lot 440 (Great Lakes Carbon Corporation (GLCC)), and SO818 (Airco Speer Division, Air Reduction Corporation (AS)) are described, and physical, mechanical, and chemical property data are presented for the graphites in the unirradiated state. A summary of the mean values of the property data and of data on TS-1240 and H-451, lot 426, is tabulated. A direct comparison of H-451, lot 426, chosen for Fort St. Vrain (FSV) fuel reload production, TS-1240, and SO818 may be made from the table. (auth)

  4. Percutaneous CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors in nonsurgical candidates; Perkutane CT-gesteuerte Hochdosis-Brachytherapie (CT-HDRBT) von primaeren und metastatischen Lungentumoren in nicht chirurgischen Kandidaten

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Schnapauff, D.; Poellinger, A.; Denecke, T.; Banzer, J.; Golenia, M.J.; Gebauer, B. [Charite - Universitatesmedizin Berlin (Germany). Inst. fuer Radiologie; Wust, P. [Charite - Universitatesmedizin Berlin (Germany). Klinik fuer Strahlentherapie

    2012-04-15

    To evaluate the safety and efficacy of CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors. Between November 2007 and May 2010, all consecutive patients with primary or metastatic lung tumors, unsuitable for surgery, were treated with CT-HDRBT. Imaging follow-up after treatment was performed with contrast-enhanced CT at 6 weeks, 3 months and every 6 months after the procedure. The endpoints of the study were local tumor control and time to progression. The Kaplan-Meier method was used to estimate survival functions and local tumor progression rates. 34 procedures were carried out on 33 lesions in 22 patients. The mean diameter of the tumors was 33.3 mm (SD = 20.4). The first contrast-enhanced CT showed that complete ablation was achieved in all lesions. The mean minimal tumor enclosing dose was 18.9 Gy (SD = 2). Three patients developed a pneumothorax after the procedure. The mean follow-up time was 13.7 (3 - 29) months. 2 of 32 lesions (6.25 %) developed a local tumor progression. 8 patients (36.3 %) developed a distant tumor progression. After 17.7 months, 13 patients were alive and 9 patients had died. CT-HDRBT ablation is a safe and attractive treatment option for patients with lung malignancies and allows targeted destruction of tumor tissue with simultaneous preservation of important lung structures. Furthermore, CT-HDRBT is independent of the size of the lesion and its location within the lung parenchyma. (orig.)

  5. Preliminary study of the scan-delay-time during the combined examation of CT perfusion and CT angiography after contrast media administration in cerebral and cervical CT angiography

    International Nuclear Information System (INIS)

    Cai Wu; Gong Jianping; Zhu Jiangtao; Qiao Fang; Chen Guangqiang; Zhang Bo; Yi Bixing; Qian Minghui

    2010-01-01

    Objective: To discuss the feasibility of the time to peak of cerebral CT perfusion (CTP) in predicting the scan-delay-time after contrast media administration in cerebral and cervical CT angiography (CTA). Methods: Retrospective Analysis was performed in eighty patients who had been examined with cerebral and cervical CTA, they were divided randomly into two groups. Group A:40 patients were performed by the method of experience of 20 seconds as scan-delay-time. Group B:the other 40 patients were examined with the combination scanning technology of CTP-CTA. They were all measured with enhancement value of CT in the M1 segment of left middle cerebral artery, superior sagittal sinus , left common carotid artery adjacent to the fourth cervical vertebrace and internal jugular vein, and then calculate the difference between the arterys and the veins in the same layer. Statistical significance was determined with t test. Results: (1)The enhancement value of CT in the cerebral and cervical artery vessels and the resolving power between the arterys and the veins in the same layer of group B were higher than that in group A. (2) Group B whose cerebral and cervical artery vessels rescontructed from the raw CT data set showed clearly; There were an advance in 3 cases (7.5%), a delay in 5 cases (12.5%) in group A whose cerebral and cervical artery vessels rescontructed from the raw CT data set didn't show clearly.Conclusion It's a satisfactory method based on successful cerebral and cervical CTA study to take the time to peak in CT perfusion as the scan-delay-time during the combined examination of CTP and CTA with 64-detector spiral CT. (authors)

  6. Dependence on Temperature, pH, and Cl"− in the Uniform Corrosion of Aluminum Alloys 2024-T3, 6061-T6, and 7075-T6

    International Nuclear Information System (INIS)

    Huang, I-Wen; Hurley, Belinda L.; Yang, Fan; Buchheit, Rudolph G.

    2016-01-01

    With regards to localized corrosion, the role of uniform corrosion of aluminum alloys has not always been accounted for in the past. The impact of uniform corrosion on aluminum alloys 2024-T3, 6061-T6, and 7075-T6 is studied here to provide quantitative evidence of its importance. Preliminary weight loss experiments combined with optical profilometry (OP) indicate that corrosion attributed to uniform corrosion is very significant when compared to localized corrosion. A series of free immersion tests were conducted to understand the influence of environmental variables including temperature (20, 40, 60, 80 °C), initial pH without buffering (3, 5, 8, 10) and chloride concentration (0.01, 0.1, 1 M) for 1, 7, and 30 days. With time, uniform corrosion results exhibited a strong dependence on temperature accompanied by variable pH- and temperature-dependent corrosion product formation. Electrochemical approaches including electrochemical impedance spectroscopy (EIS) and cathodic polarization were utilized to characterize the oxygen reduction reaction (ORR) and corrosion product formation as a function of temperature. Electron microscopy was conducted to assess the microstructure and morphology of corrosion products and provide supporting evidence for electrochemical findings.

  7. Major Histocompatibilty Complex-Restricted Adaptive Immune Responses to CT26 Colon Cancer Cell Line in Mixed Allogeneic Chimera.

    Science.gov (United States)

    Lee, K W; Choi, B; Kim, Y M; Cho, C W; Park, H; Moon, J I; Choi, G-S; Park, J B; Kim, S J

    2017-06-01

    Although the induction of mixed allogeneic chimera shows promising clinical tolerance results in organ transplantation, its clinical relevance as an anti-cancer therapy is yet unknown. We introduced a mixed allogenic chimera setting with the use of a murine colon cancer cell line, CT26, by performing double bone marrow transplantation. We analyzed donor- and recipient-restricted anti-cancer T-cell responses, and phenotypes of subpopulations of T cells. The protocol involves challenging 1 × 10 5 cells of CT26 cells intra-hepatically on day 50 after bone marrow transplantation, and, by use of CT26 lysates and an H-2L d -restricted AH1 pentamer, flow cytometric analysis was performed to detect the generation of cancer-specific CD4 + and CD8 + T cells at various time points. We found that immunocompetence against tumors depends heavily on cancer-specific CD8 + T-cell responses in a major histocompatibility complex-restricted manner; the evidence was further supported by the increase of interferon-γ-secreting CD4 + T cells. Moreover, we demonstrated that during the effector immune response to CT26 cancer challenge, there was a presence of central memory cells (CD62L hi CCR7 + ) as well as effector memory cells (CD62L lo CCR7 - ). Moreover, mixed allogeneic chimeras (BALB/c to C56BL/6 or vice versa) showed similar or heightened immune responses to CT26 cells compared with that of wild-type mice. Our results suggest that the responses of primary immunocompetency and of pre-existing memory T cells against allogeneic cancer are sustained and preserved long-term in a mixed allogeneic chimeric environment. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. The clinical value and pitfalls of 18F-fluoroethylcholine PET/CT imaging in the diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Zhou Shuo; Lin Meifu; Chen Wenxin; Chen Guobao; Li Junxia

    2012-01-01

    Objective: To evaluate the clinical value of 18 F-fluoroethylcholine (FECH) PET/CT imaging in the diagnosis of prostate cancer and to investigate its physiological or non-cancerous uptake. Methods: The subjects consisted of 30 patients (age ranged from 56 to 83 years, mean age 61 years) with pathologically confirmed prostate cancer, in whom 18 F-FECH and 18 F-FDG PET/CT scans were undertaken from October 2009 to December 2011. The sensitivity and accuracy of the two tracers in detecting prostate cancer were compared.SUV max was obtained for quantitative analysis. χ 2 test and t test were used for statistic analysis. Results: Of the 30 patients, 41 lesions presented high uptake in prostate region. The sensitivity and accuracy for diagnosing prostate cancer with 18 F-FECH PET/CT were 87.9% (29/33) and 82.9%(34/41), respectively, while the sensitivity and accuracy with 18 F-FDG PET/CT were 36.4% (12/33) and 36.6% (15/41), respectively. There were significant differences in sensitivity and accuracy between the two methods (χ 2 =8.1 and 11.1, both P<0.05). Physiological uptake appeared in the liver, pancreas, spleen, salivary gland, and also, owing to renal excretion,in the urinary tract. The SUV max in liver and pancreas were 10.1 ± 1.6 and 6.1 ± 1.1, respectively. The SUV max was 6.0 ± 2.2 in prostate cancer, while it was 2.6 ± 1.3 in benign lesions (t=2.9, P<0.05). Other abnormalities that were not related to prostate cancer were detected in 10 patients. Of these 10 patients, there were 6 with inflammation, 1 with lymphoma, 1 with tuberculosis, 1 with lung cancer and 1 with germinoma in pineal body. Conclusions: 18 F-FECH PET/CT is promising for diagnosis of prostate cancer.Understanding the biodistribution and pitfalls of 18 F-FECH is very important for image interpretation. (authors)

  9. Association of the miR-196a2 C>T and miR-499 A>G polymorphisms with hepatitis B virus-related hepatocellular carcinoma risk: an updated meta-analysis

    Directory of Open Access Journals (Sweden)

    Zhu SL

    2016-04-01

    Full Text Available Shao-Liang Zhu,1,* Jian-Hong Zhong,1,* Wen-Feng Gong,1,* Hang Li,2 Le-Qun Li11Department of Hepatobiliary Surgery, 2Department of Ultrasound, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, People’s Republic of China*These authors contributed equally to this workBackground: This study meta-analyzed data on the possible association of the miR-196a2 C>T (rs11614913 and miR-499 A>G (rs3746444 polymorphisms with risk of hepatitis B virus (HBV-related hepatocellular carcinoma (HCC.Methods: Databases in PubMed, EMBASE, Web of Science, China BioMedicine, and Google Scholar were systematically searched to identify relevant studies. Meta-analyses were performed to examine the association of the miR-196a2 C>T and miR-499 A>G polymorphisms with HBV-related HCC risk. Odds ratios (ORs and 95% confidence intervals (95% CIs were calculated.Results: A total of 13 studies involving 3,964 cases and 5,875 healthy controls were included. Random-effect meta-analysis showed that the T allele and TT genotype of miR-196a2 C>T were associated with significantly lower HBV-related HCC risk (allelic model, OR =0.84, 95% CI =0.71–0.99, P=0.04; homozygous model, OR =0.68, 95% CI =0.47–0.98, P=0.04. In contrast, miR-499 A>G showed no significant association with HBV-related HCC risk in either overall pooled analysis or ethnic subgroup analysis according to any of the four genetic models. Based on analysis of ethnic subgroups, neither miR-196a2 C>T nor miR-499 A>G was significantly associated with risk of HBV-related HCC in Chinese population.Conclusion: The polymorphism miR-196a2 C>T, but not miR-499 A>G, may be associated with decreased HBV-related HCC risk. These conclusions should be verified in large, well-designed studies.Keywords: microRNA, single nucleotide polymorphisms, hepatitis B virus related, meta-analysis, hepatocellular carcinoma

  10. The validity and findings of superselective angio-CT of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tomura, Noriaki; Kusaka, Kazuya; Kato, Koki; Sato, Kimihiko; Watarai, Jiro; Sasajima, Hiroyasu; Kowada, Masayoshi [Akita Univ. (Japan). School of Medicine; Hatayama, Takashi

    1995-09-01

    Superselective angio-CT (SSA-CT) was performed on 12 patients with malignant astrocytomas who had been treated with superselective intra-arterial infusions of ACNU. SSA-CT was done at the time of super-selective intra-arterial infusion. Following conventional intra-arterial DSA for which a 6-F catheter was used, a microcatheter (Tracker-18) was passed coaxially inside the guiding catheter, and advanced into the feeding arteries of the tumor. After the microcatheter was placed in the proper position, a dynamic CT was performed with contrast administration into the feeding arteries. A GE CT/T 9800 scanner was used; the contrast medium was iopamidol which was administered diluted with 5 volumes of saline. There was representation of tumor stains by SSA-CT in all 12 patients, and of the medullary veins in three. In contrast, DSA or conventional enhanced CT represented tumor stain/enhancement in only 10 patients, and the medullary veins in one. In two patients who had no contrast tumor enhancement on the CT with contrast, SSA-CT could represent tumor stain. SSA-CT was also superior to DSA and conventional CT for the visualization of medullary veins The feeding artery in a patient with a posterior frontal astrocytoma was unclear on DSA. However, SSA-CT with contrast administration in the anterior cerebral artery revealed tumor stain; this modality was also useful for identifying the artery to be used for ACNU infusion. In another patient with a tumor in the parahippocampal gyrus, SSA-CT with contrast administration in the posterior cerebral artery could provide the proper position of the catheter for the infusion of ACNU. None of the patients experienced complications due to catheterization nor any systemic side-effects. (H.O.).

  11. CT and MR imaging of craniopharyngioma

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, M. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Takahashi, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Higano, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Kurihara, N. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Ikeda, H. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Neurosurgery; Sakamoto, K. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology

    1997-05-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  12. CT and MR imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Tsuda, M.; Takahashi, S.; Higano, S.; Kurihara, N.; Ikeda, H.; Sakamoto, K.

    1997-01-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  13. Normal appearance and size of the diaphragmatic crura in children: CT evaluation

    International Nuclear Information System (INIS)

    Brengle, M.; Cohen, M.D.; Katz, B.

    1996-01-01

    Purpose. The objectives of the study were to document the normal CT appearance and size of the crura of the diaphragm in children. Materials and methods. The CT scans of 80 children (0-15 years) were reviewed. The children were divided into eight age groups. The maximal transverse diameters of the right and left crura were measured. They were normalized by comparison with the transverse and anterior-posterior diameters of the 12th thoracic vertebra (T12) and the transverse abdominal diameter at T12. The crura were also evaluated as to whether their contour was smooth or nodular. Results. The diaphragmatic crura of smaller children appear large, relative to body size and the diameters of the T12 vertebral body, compared with those in older children. Crural width does not increase significantly with age. Additionally, the crura were found to have a greater tendency to be nodular in appearance in children under the age of 5 years than in older children. Conclusion. Diaphragmatic crura are more nodular and larger relative to body size in younger children. (orig.). With 6 figs., 2 tabs

  14. CT diagnosis of mediastinal tuberculous lymphadenopathy in adults

    International Nuclear Information System (INIS)

    Liu Fugeng; Pan Jishu; Wu Guogeng; Chen Qihang; Yu Jingying; Zhou Cheng

    2001-01-01

    Objective: To evaluate the features of mediastinal tuberculous lymphadenopathy in adults on CT, especially on enhanced CT scan. Methods: Seventeen patients with adult mediastinal tuberculous lymphadenopathy proved by operation, biopsy, and (or) anti-tuberculous therapy were evaluated on chest film and CT scan, and 6 patients were performed with enhanced CT scan. Results: The chest film finding was intrathoracic mass and (or) hilar mass only in 6 patients, but CT detected 37 enlarged nodes in all patients. Most of the enlarged nodes were located in 2R and (or) 4R (59.4%). 30 nodes (81.1%) presented as low-density in the center of nodes, and there were marked enhancement at the periphery areas of the nodes after enhancement in all 6 patients (100.0%). Conclusion: CT scan, especially the enhanced CT scan, is the first method of choice to diagnose the mediastinal tuberculous lymphadenopathy in adults

  15. Oral contrast medium in PET/CT: should you or shouldn't you?

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Dickson, John C.; Townsend, Caroline; Croasdale, Ian; Syed, Rizwan; Nagabushan, Nagesh; Hain, Sharon F.; Ell, Peter J.; Bomanji, Jamshed B.

    2005-01-01

    It has been suggested that the use of computed tomography (CT) positive contrast agents has led to attenuation-induced artefacts on 18 F-fluorodeoxyglucose positron emission tomography ( 18 F-FDG PET/CT) systems. Consequently, centres may withhold the use of such agents. Whilst there is theoretical evidence to support the aforementioned claim, the clinical relevance of the induced artefacts has not been widely established. Moreover, the potential benefits of bowel enhancement on PET/CT have yet to be formally evaluated. We therefore prospectively examined PET/CT studies to assess whether the use of oral contrast medium induces clinically relevant artefacts and whether the use of these agents is diagnostically helpful. Over a 2-month period, 18 F-FDG PET/CT images were prospectively reviewed from 200 patients following Gastrografin administration 2 h prior to examination. Both a radiologist and a nuclear medicine physician reviewed the images for contrast medium-mediated clinically relevant artefacts. Artefacts were sought on the CT attenuation-corrected images and were compared with the appearance on non-attenuated-corrected images. The number of examinations in which the oral contrast aided image interpretation was also noted. There were no oral contrast medium-induced clinically significant artefacts. In 38 of the 200 patients, oral contrast aided image interpretation (owing to differentiation of mass/node from bowel, discrimination of intestinal wall from lumen or definition of the anatomy of a relevant site). In 33 of these 38 patients, the anatomical site of interest was the abdomen/pelvis. The use of oral contrast medium in 18 F-FDG PET studies should not be withheld as it improves image interpretation and does not produce clinically significant artefacts. (orig.)

  16. Chromosome dosimetry: the influence of culture media on the proliferation of irradiated and unirradiated human lymphocytes

    International Nuclear Information System (INIS)

    Purrott, R.J.; Lloyd, D.C.; Vulpis, N.

    1981-01-01

    The proliferation of phytohaemagglutinin stimulated human lymphocytes in four types of synthetic culture medium has been studied using the fluorescence plus Giemsa staining technique to determine cell cycle status. 48 hour cultures of unirradiated cells containing Ham's F10 or RPMI 1640 media yielded significant numbers of second cycle metaphases. Cultures containing Eagle's MEM or TC 199 media, however, required longer incubation times to produce appreciable numbers of second division cells. Intrinsic differences between donors in the rate of proliferation had little effect on the relative ranking of the media. Radiation induced mitotic delay of about 1 hour per Gray was observed for each medium. The relevance of these results to the accuracy of radiation dose estimation by chromosome aberration analysis is discussed. (author)

  17. CT features of appendiceal mucocele

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Won Jong; Byun, Jae Young; Jung, Jung Im; Lee, Hae Gyu; Park, Young Ha; Shin, Kyung Sub [Catholic University Medical College, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate the usefulness of CT features of appendiceal mucocele in the diagnosis and evaluation of complications. We retrospectively reviewed CT findings and compared with operative findings in 7 cases of pathologically proven appendiceal mucocele. CT findings such as location and extent of the lesion, tissue density, thickness or calcification of the wall, presence of adjacent inflammatory infiltration, and visualization of normal vermiform appendix were analyzed. Appendiceal mucocele was found as homogeneous low density cystic mass adjacent to the cecum, which has no surrounding inflammatory infiltration except in one case of perforation and one case of intussusception. Mean CT number measured in 4 cases was 21 Hounsfield unit. Thin curvilinear calcifications were noted along the cystic wall in 2 cases. Normal vermiform appendix couldn't be demonstrated in all cases. Appendiceal mucocele is characterized by homogeneously low density and thin walled cystic tumor adjacent to cecum without surrounding inflammatory infiltration, and absence of normal vermiform appendix on CT. Therefore, CT is valuable in preventing operative complications of appendiceal mucocele.

  18. Identification of c.483C>T polymorphism in the caprine tyrosinase-related protein 1 (TYRP1 gene

    Directory of Open Access Journals (Sweden)

    Bouabid Badaoui

    2012-03-01

    Full Text Available Tyrosinase-related protein 1 (TYRP1 has been shown to play a fundamental role in pigmentation both in human and mouse. In this work, we aimed to characterize the variability of the caprine TYRP1 gene and investigate its segregation in a wide array of goat breeds. By partially sequencing the coding region of the TYRP1 gene in 18 individuals from eight different breeds, we were able to identify a synonymous nucleotide substitution at exon 3 (c.483C>T. An extensive survey of Iberian and Balearic (N=175, Italian (N=99, Swiss (N=54, Asian (N=14, Canarian (N=92 and North African (N=117 goats with different coat colours was carried out. We found that the C-allele has a different distribution in European vs African breeds, being almost fixed in the latter. Moreover, the C-allele showed an increased frequency in white coated breeds (Girgentana, Grigia Molisana, Blanca de Rasquera and Saanen when compared with those displaying a dark pigmentation (Cilentana Nera, Azpi Gorri and Murciano- Granadina. This could be due to genetic drift, migration and other factors associated with the demographic history of breeds under analysis or to a genetic hitchhiking event (c.483C>T frequencies would be shaped by a neighbouring causal mutation differentially selected in white and black goats. More refined studies will be needed to distinguish between these two alternative explanations.

  19. Identification of c.483C>T polymorphism in the caprine tyrosinase-related protein 1 (TYRP1 gene

    Directory of Open Access Journals (Sweden)

    Marcel Amills

    2012-01-01

    Full Text Available Tyrosinase-related protein 1 (TYRP1 has been shown to play a fundamental role in pigmentation both in human and mouse. In this work, we aimed to characterize the variability of the caprine TYRP1 gene and investigate its segregation in a wide array of goat breeds. By partially sequencing the coding region of the TYRP1 gene in 18 individuals from eight different breeds, we were able to identify a synonymous nucleotide substitution at exon 3 (c.483C>T. An extensive survey of Iberian and Balearic (N=175, Italian (N=99, Swiss (N=54, Asian (N=14, Canarian (N=92 and North African (N=117 goats with different coat colours was carried out. We found that the C-allele has a different distribution in European vs African breeds, being almost fixed in the latter. Moreover, the C-allele showed an increased frequency in white coated breeds (Girgentana, Grigia Molisana, Blanca de Rasquera and Saanen when compared with those displaying a dark pigmentation (Cilentana Nera, Azpi Gorri and Murciano- Granadina. This could be due to genetic drift, migration and other factors associated with the demographic history of breeds under analysis or to a genetic hitchhiking event (c.483C>T frequencies would be shaped by a neighbouring causal mutation differentially selected in white and black goats. More refined studies will be needed to distinguish between these two alternative explanations.

  20. Prescreening based on the presence of CT-scan abnormalities and biomarkers (KL-6 and SP-D may reduce severe radiation pneumonitis after stereotactic radiotherapy

    Directory of Open Access Journals (Sweden)

    Wakui Reiko

    2010-05-01

    Full Text Available Abstract Purpose To determine the risk factors of severe radiation pneumonitis (RP after stereotactic body radiation therapy (SBRT for primary or secondary lung tumors. Materials and methods From January 2003 to March 2009, SBRT was performed on 117 patients (32 patients before 2005 and 85 patients after 2006 with lung tumors (primary = 74 patients and metastatic/recurrent = 43 patients in our institution. In the current study, the results on cases with severe RP (grades 4-5 were evaluated. Serum Krebs von den Lungen-6 (KL-6 and serum Surfactant protein-D (SP-D were used to predict the incidence of RP. A shadow of interstitial pneumonitis (IP on the CT image before performing SBRT was also used as an indicator for RP. Since 2006, patients have been prescreened for biological markers (KL-6 & SP-D as well as checking for an IP-shadow in CT. Results Grades 4-5 RP was observed in nine patients (7.7% after SBRT and seven of these cases (6.0% were grade 5 in our institution. A correlation was found between the incidence of RP and higher serum KL-6 & SP-D levels. IP-shadow in patient's CT was also found to correlate well with the severe RP. Severe RP was reduced from 18.8% before 2005 to 3.5% after 2006 (p = 0.042. There was no correlation between the dose volume histogram parameters and these severe RP patients. Conclusion Patients presenting with an IP shadow in the CT and a high value of the serum KL-6 & SP-D before SBRT treatment developed severe radiation pneumonitis at a high rate. The reduction of RP incidence in patients treated after 2006 may have been attributed to prescreening of the patients. Therefore, pre-screening before SBRT for an IP shadow in CT and serum KL-6 & SP-D is recommended in the management and treatment of patients with primary or secondary lung tumors.

  1. Side-by-side reading of PET and CT scans in oncology: Which patients might profit from integrated PET/CT?

    International Nuclear Information System (INIS)

    Reinartz, Patrick; Wieres, Franz-Josef; Schneider, Wolfram; Schur, Alexander; Buell, Ulrich

    2004-01-01

    Most early publications on integrated positron emission tomography/computed tomography (PET/CT) devices have reported the new scanner generation to be superior to conventional PET. However, few of these studies have analysed the situation where, in addition to PET, a current CT scan is available for side-by-side viewing. This fact is important, because combined PET/CT or a software-based fusion of the two modalities may improve diagnosis only in cases where side-by-side reading of PET and CT data does not lead to a definitive diagnosis. The aim of this study was to analyse which patients will profit from integrated PET/CT in terms of lesion characterization. A total of 328 consecutively admitted patients referred for PET in whom a current CT scan was available were included in the study. The localization of all pathological PET lesions, as well as possible infiltration of adjacent anatomical structures, was assessed. Of 467 pathological lesions, 94.0% were correctly assessed with respect to localization and infiltration by either conventional PET alone (51.6%) or combined reading of PET and the already existing CT scans (42.4%). Hence, in only 6.0% of all lesions, affecting 6.7% of all patients, could evaluation have profited from integrated PET/CT. We conclude that side-by-side viewing of PET and CT scans is essential, as in 42.4% of all cases, combined viewing was important for a correct diagnosis in our series. In up to 6.7% of patients, integrated PET/CT might have given additional information, so that in nearly 50% of patients some form of combined viewing of PET and CT data is needed for accurate lesion characterization. (orig.)

  2. Interleukin-1β and interleukin-6 gene polymorphisms are associated with manifestations of sickle cell anemia.

    Science.gov (United States)

    Vicari, Perla; Adegoke, Samuel A; Mazzotti, Diego Robles; Cançado, Rodolfo Delfini; Nogutti, Maria Aparecida Eiko; Figueiredo, Maria Stella

    2015-03-01

    Sickle cell anemia (SCA), a disorder characterized by both acute and chronic inflammation, exhibits substantial phenotypic variability. Interleukin-1 beta (IL-1β) and IL-6 are important in acute and chronic diseases, and their single nucleotide polymorphisms (SNPs) have been considered as predictors of prognosis in several inflammatory conditions. This study aims at exploring possible association of IL-1β and IL-6 SNPs as potential genetic modifiers and or predictors of SCA clinical and laboratory phenotypes. This cross-sectional study involved 107 SCA patients and 110 age, sex and ethnicity-matched healthy individuals. The SNPs were identified by PCR-RFLP for IL-1β (-511C>T and +3954C>T) and IL-6 (-597G>A and -174G>C) genes. Associations between these SNPs and the clinical and laboratory profiles of patients with SCA were then determined. Allelic and genotypic frequencies of IL-1β and IL-6 SNPs between patients with SCA and controls were similar and followed HWE. IL-1β +3954C>T SNP was associated with increased risk of osteonecrosis, elevated pulmonary arterial pressure and lower absolute reticulocyte count, while IL-6 -597G>A was associated with higher likelihood of retinopathy and leg ulcer. These data indicate that IL-1β and IL-6 gene SNPs are associated with SCA complications among Brazilian patients and may act as genetic predictors of SCA clinical heterogeneity. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Posterior reversible encephalopathy syndrome: diagnosis with CT and MRI

    International Nuclear Information System (INIS)

    Wang Guangbin; Zhao Bin; Yang Zhenzhen; Shi Hao; Chiu, L.C.; Shan Ruiqin

    2006-01-01

    Objective: To evaluate the role of CT and MRI in the diagnosis of posterior reversible encephalopathy syndrome (PRES). Methods: Eight women with PRES (6 pregnant women, 1 case after chemotherapy, and 1 patient with hypertension)were enrolled in our study. All of them had MR imaging (T 1 WI, T 2 WI, FLAIR, DWI), and five cases underwent post-contrast T 1 WI and three dimensional contrast enhanced MR angiography (3D CEMRA). Two cases also had CT scan. Results: MRV in all 8 patients showed no evidence of stenosis, dilation, or thrombosis in cranial veins and sinuses. MRI demonstrated multiple lesions located in bilateral parieto-occipital lobes (8 cases), bilateral basal ganglia (2 cases), and bilateral frontal lobes (4 cases). The lesions were prominent within white matter, some of them involved gray matter (3 cases). Lesions appeared as hyperintense signals on FLAIR and T 2 -weighted images, isointense or mildly hypointense signals on T 1 -weighted images, normal or decreased intensity on DWI, and isointensity or hyperintensity on apparent diffusion coefficient (ADC) maps. Post-contrast T 1 WI showed mild reversible enhancement and 3D CEMRA displayed numerous reversible 'grape-like' enhancements in terminal arterial branches along the middle cerebral artery (MCA), anterior cerebral artery (ACA) and posterior cerebral artery (PCA). Follow-up scan showed decreased abnormal signals. Conclusion: Lesions of PRES are usually located in parieto-occipital lobes, especially in white matter, but they can also be seen in frontal lobes and basal ganglia bilaterally. Post-contrast T 1 WI and 3D enhanced MRA can provide useful information in the manifestation of reversible enhancement. MRI has advantages to display lesion in PRES. (authors)

  4. Cone-Beam Computed Tomography (CBCT) Versus CT in Lung Ablation Procedure: Which is Faster?

    Energy Technology Data Exchange (ETDEWEB)

    Cazzato, Roberto Luigi, E-mail: r.cazzato@unicampus.it; Battistuzzi, Jean-Benoit, E-mail: j.battistuzzi@bordeaux.unicancer.fr; Catena, Vittorio, E-mail: vittoriocatena@gmail.com [Institut Bergonié, Department of Radiology (France); Grasso, Rosario Francesco, E-mail: r.grasso@unicampus.it; Zobel, Bruno Beomonte, E-mail: b.zobel@unicampus.it [Università Campus Bio-Medico di Roma, Department of Radiology and Diagnostic Imaging (Italy); Schena, Emiliano, E-mail: e.schena@unicampus.it [Università Campus Bio-Medico di Roma, Unit of Measurements and Biomedical Instrumentations, Biomedical Engineering Laboratory (Italy); Buy, Xavier, E-mail: x.buy@bordeaux.unicancer.fr; Palussiere, Jean, E-mail: j.palussiere@bordeaux.unicancer.fr [Institut Bergonié, Department of Radiology (France)

    2015-10-15

    AimTo compare cone-beam CT (CBCT) versus computed tomography (CT) guidance in terms of time needed to target and place the radiofrequency ablation (RFA) electrode on lung tumours.Materials and MethodsPatients at our institution who received CBCT- or CT-guided RFA for primary or metastatic lung tumours were retrospectively included. Time required to target and place the RFA electrode within the lesion was registered and compared across the two groups. Lesions were stratified into three groups according to their size (<10, 10–20, >20 mm). Occurrences of electrode repositioning, repositioning time, RFA complications, and local recurrence after RFA were also reported.ResultsForty tumours (22 under CT, 18 under CBCT guidance) were treated in 27 patients (19 male, 8 female, median age 67.25 ± 9.13 years). Thirty RFA sessions (16 under CBCT and 14 under CT guidance) were performed. Multivariable linear regression analysis showed that CBCT was faster than CT to target and place the electrode within the tumour independently from its size (β = −9.45, t = −3.09, p = 0.004). Electrode repositioning was required in 10/22 (45.4 %) tumours under CT guidance and 5/18 (27.8 %) tumours under CBCT guidance. Pneumothoraces occurred in 6/14 (42.8 %) sessions under CT guidance and in 6/16 (37.5 %) sessions under CBCT guidance. Two recurrences were noted for tumours receiving CBCT-guided RFA (2/17, 11.7 %) and three after CT-guided RFA (3/19, 15.8 %).ConclusionCBCT with live 3D needle guidance is a useful technique for percutaneous lung ablation. Despite lesion size, CBCT allows faster lung RFA than CT.

  5. CT and MRI features of acinar cell carcinoma of the pancreas with pathological correlations

    International Nuclear Information System (INIS)

    Hsu, M.-Y.; Pan, K.-T.; Chu, S.-Y.; Hung, C.-F.; Wu, R.-C.; Tseng, J.-H.

    2010-01-01

    Aim: To document the computed tomography (CT) and magnetic resonance imaging (MRI) features of acinar cell carcinoma of the pancreas and to correlate them with pathological findings to determine the unique imaging manifestations of this rare subtype tumour of the pancreas. Materials and methods: From January 1986 to August 2008, six patients (five men and one woman, mean age 61.3 years) with histologically proven acinar cell carcinoma of the pancreas underwent CT (n = 6) and MRI (n = 4) examinations. The imaging features of each tumour were documented and compared with pathological findings. Results: The tumours were distributed in the head (n = 4), body (n = 1), and tail (n = 1) of the pancreas. Four masses (67%) were uniformly or partially well-defined with thin, enhancing capsules. Central cystic components were found in five tumours (83%). Two tumours (33%) exhibited intratumoural haemorrhage, and one tumour (17%) had amorphous intratumoural calcification. In both CT and MRI, the tumours enhanced less than the adjacent normal pancreatic parenchyma. The signal intensity on MRI was predominantly T1 hypointense and T2 iso- to hyperintense. Conclusion: Acinar cell carcinoma of the pancreas has distinct imaging features, and both CT and MRI are useful and complementary imaging methods.

  6. The effects of irradiation to 8x1026m-2 on the mechanical properties of 6061-T651 aluminum

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1995-01-01

    The effects of irradiation on the mechanical properties of candidate structural materials are being examined. A key to the generation of useful neutron beams is allowing the neutrons produced in the core to escape. Therefore, an aluminum alloy has been selected for the first wall containment adjacent to the core, the Core Pressure Boundary Tube (CPBT), Alloy (6061 J651 Al 1.0Mg-0.6Si-0.3Cu-0.2Cr) with acceptable mechanical properties in unirradiated condition, low neutron cross-section, high thermal conductivity for heat removal. This alloy may also be used for the beam tubes and reflector tank. An irradiation program is underway to determine the effects of irradiation on the mechanical properties of 6061-T651 aluminium in particular the fracture toughness. This data will allow the operating lifetime of the CPBT to determined which will in turn determine its replacement schedule in the ANS. The first two capsules for the ANS Irradiation Effects program have been successfully irradiated to 10 26 and 8x10 26 m -2 (thermal flux), respectively, at a nominal irradiation temperature of 95 deg. C. The testing of the specimens of 6061-T651 aluminum has shown: 1. The yield and ultimate tensile strengths are increased by irradiation; 2. The uniform and total elongations are reduced, but useful ductility remains, even at the higher irradiation level; 3. The fracture toughness at 25 deg. C and 95 deg. C is unaffected by irradiation, but at 150 deg. C, it decreases with an increase in irradiation; 4. The tearing modulus of 6061-T651 is low in the unirradiated condition, and is reduced to very low values by irradiation. This alloy also shows a tendency for sudden unstable crack extension

  7. c.29C>T polymorphism in the transforming growth factor-β1 (TGFB1) gene correlates with increased risk of urinary bladder cancer.

    Science.gov (United States)

    Gautam, Kirti Amresh; Pooja, Singh; Sankhwar, Satya Narayan; Sankhwar, Pushp Lata; Goel, Apul; Rajender, Singh

    2015-10-01

    TGF-β1 is a pleiotropic cytokine, which plays a dual role in tumor development. In the early stages, it inhibits the growth of tumor while in the late stages of carcinoma, it promotes tumor growth. The purpose of this study was to analyze the distribution of the TGFB1 gene polymorphisms between cases and controls so as to assess their correlation with bladder cancer risk. This study included 237 cases of urinary bladder cancer and 290 age matched controls from the same ethnic background. Three polymorphisms in the TGFB1 gene, c.29C>T (rs-1800470), c.74G>C (rs-1800471) and +140A>G (rs-13447341), were analyzed by direct DNA sequencing. Statistical analyses revealed no significant differences in the demographical data, except that the frequencies of smokers and non-vegetarians were higher in the cases. Eighty percent of the bladder cancer patients had superficial transitional cell carcinoma, and 53.16% and 26.31% of the patients were in grade I and grade II, respectively. We found that c.29C>T substitution increased the risk of bladder cancer significantly and recessive model of analysis was the best fitted model (p=0.004; OR=1.72 95% CI 1.18-2.50). A significantly higher risk in the recessive form was also suggested by co-dominant analysis showing that the homozygous form (TT) was a significant risk factor in comparison to CC and CT genotypes. The other two polymorphisms, c.74G>C (p=0.18, OR=0.67 95% CI 0.37-1.21) and +140A>G (p=0.416, OR=0.77 95% CI 0.41-1.45) did not affect the risk of urinary bladder cancer. In conclusion, we found that the TGFB1 c.29C>T substitution increases the risk of bladder cancer significantly while c.74G>C and +140A>G polymorphisms do not affect the risk. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. CT grading scales for splenic injury: why can't we agree?

    International Nuclear Information System (INIS)

    Clark, Rhys; Hird, Kathryn

    2011-01-01

    Full text: Computed tomography (CT) has been proven to be able to accurately diagnose splenic injury, Many have published CT splenic injury grading scales to quantify the extent of injury, However, these scales have failed at predicting clinical outcomes and therefore cannot be used to accu rately predict the need for intervention. We hypothesi sed that low interrater reliability is the reason why these scales have failed at predicting clinical outcomes. This is a retrospective study of patients who were admitted to the Royal Perth Hospital with blunt splenic injury as coded in the trauma registry, The abdominal CT images of these patients were reviewed by three consultant radiologists and were graded using the six different splenic injury grading scales. We assessed interrater reliability between each of the scales using generalised kappa and proportion of agreement calculations. Results: The images of 64 patients were reviewed. The interrater reliability yielded a generalised kappa score of 0.32-0,60 and proportion of agreement ranging from 34,4% to 65,5%, The six studied CT splenic injury grading scales did not have a high enough interrater reliability to be adequate for clinical use, The poor interrater reliability is likely to contribute to the failure of the scales at predicting clinical outcomes. Further research to improve the interrater reliability is recommended.

  9. Castleman disease of the neck: CT and MR imaging findings

    International Nuclear Information System (INIS)

    Jiang, Xin-hua; Song, Hao-ming; Liu, Qing-yu; Cao, Yun; Li, Guo-hong; Zhang, Wei-dong

    2014-01-01

    Objective: To characterize the computed tomography (CT) and magnetic resonance imaging (MRI) findings of Castleman disease of the neck. Methods: The imaging findings of 21 patients with Castleman disease of the neck were reviewed retrospectively. Of the 21 patients, 16 underwent unenhanced and contrast-enhanced CT scans; 5 underwent unenhanced and contrast-enhanced MRI scans. Results: The unenhanced CT images showed isolated or multiple well-defined homogenous mild hypodensity lesions in fifteen cases, and a heterogeneous nodule with central areas of mild hypodensity in one case. Calcification was not observed in any of the patients. In five patients, MR T1-weighted images revealed well-defined, homogeneous isointense or mild hyperintense lesions to the muscle; T2-weighted images showed these as intermediate hyperintense. Sixteen cases showed intermediate to marked homogeneous enhancement on contrast-enhanced CT or MR T1-weighted images. Of the other five cases that underwent double-phase CT scans, four showed mild or intermediate heterogeneous enhancement at the arterial phase, and homogeneous intermediate or marked enhancement at the venous phase; the remaining case showed mild and intermediate ring-enhancement with a central non-enhanced area at the arterial and venous phases, respectively. Conclusion: Castleman disease of the neck can be characterized as solitary or multiple well-defined, mild hypodensity or homogeneous intense lesions on plain CT/MR scans, and demonstrates intermediate and marked enhancement on contrast-enhanced CT/MR scans. On double-phase CT scans, Castleman disease often demonstrates mild enhancement at the arterial phase, and gradually uniform enhancement at venous phase. Double-phase enhanced CT or MRI may help to differentiate Castleman disease from other diseases

  10. Castleman disease of the neck: CT and MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xin-hua [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Song, Hao-ming [Department of Cardiology, Shanghai Tongji Hospital, Shanghai 200065 (China); Liu, Qing-yu [Department of Radiology, The Second Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510120 (China); Cao, Yun [Department of Pathology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Li, Guo-hong [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Zhang, Wei-dong, E-mail: dongw.z@163.com [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China)

    2014-11-15

    Objective: To characterize the computed tomography (CT) and magnetic resonance imaging (MRI) findings of Castleman disease of the neck. Methods: The imaging findings of 21 patients with Castleman disease of the neck were reviewed retrospectively. Of the 21 patients, 16 underwent unenhanced and contrast-enhanced CT scans; 5 underwent unenhanced and contrast-enhanced MRI scans. Results: The unenhanced CT images showed isolated or multiple well-defined homogenous mild hypodensity lesions in fifteen cases, and a heterogeneous nodule with central areas of mild hypodensity in one case. Calcification was not observed in any of the patients. In five patients, MR T1-weighted images revealed well-defined, homogeneous isointense or mild hyperintense lesions to the muscle; T2-weighted images showed these as intermediate hyperintense. Sixteen cases showed intermediate to marked homogeneous enhancement on contrast-enhanced CT or MR T1-weighted images. Of the other five cases that underwent double-phase CT scans, four showed mild or intermediate heterogeneous enhancement at the arterial phase, and homogeneous intermediate or marked enhancement at the venous phase; the remaining case showed mild and intermediate ring-enhancement with a central non-enhanced area at the arterial and venous phases, respectively. Conclusion: Castleman disease of the neck can be characterized as solitary or multiple well-defined, mild hypodensity or homogeneous intense lesions on plain CT/MR scans, and demonstrates intermediate and marked enhancement on contrast-enhanced CT/MR scans. On double-phase CT scans, Castleman disease often demonstrates mild enhancement at the arterial phase, and gradually uniform enhancement at venous phase. Double-phase enhanced CT or MRI may help to differentiate Castleman disease from other diseases.

  11. Temporal lobe epilepsy: Comparison of CT and MR in 100 patients

    International Nuclear Information System (INIS)

    Schoerner, W.; Meencke, H.J.; Sander, B.; Henkes, H.; Felix, R.; Klinikum Rudolf Virchow, Berlin

    1989-01-01

    The value of CT and MR was studied in 100 patients with temporal lobe epilepsy. Axial CT scans were obtained before and after contrast injection. Coronary MR scans were carried out with T 1 -(SE 400/30, GE 315/14) and T 2 -weighted sequences (SE 1600/30 + 70). A circumscribed lesion was demonstrated in fifteen patients by CT and in 25 patients by MR. With the exception of a small area of calcification, all lesions seen on CT could also be recognized on MR. Better sensitivity and improved demonstration of the temporal lobes makes MR the method of choice in the diagnosis of temporal lobe epilepsy. (orig./GDG) [de

  12. MR and CT for malignant hypernephromas

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Fischer, C.; Ruehl, G.; Beyer, H.K.; Hummelsheim, P.; Bochum Univ.; Marienhospital, Herne; Bochum Univ.

    1987-01-01

    Forty patients with histologically confirmed hypernephromas were examined by MR and CT. As regards T-staging, MR had an accuracy of 97 % and CT of 91%; for N-staging, MR had an accuracy of 85% and CT of 91% and, with regard to infiltration of the renal vein, MR was correct in 88% of cases and CT in 81%. MR was most accurate in the pre-operative assessment of tumour spread, demonstrating caval involvement in 100% and lymph node metastases in 97%. On the other hand, infiltration of the renal pelvis could be assessed in only 65% of cases; in 27% the assessment was not possible and in 8% one could not be certain. CT proved to be at its best for staging of lymph nodes, but in 15% it was not possible to identify infiltration of the renal vein. MR was not greatly superior to CT in the preoperative diagnosis and staging of hypernephromas. (orig.) [de

  13. Use of the CT component of PET-CT to improve PET-MR registration: demonstration in soft-tissue sarcoma

    International Nuclear Information System (INIS)

    Somer, Edward J; Benatar, Nigel A; O'Doherty, Michael J; Smith, Mike A; Marsden, Paul K

    2007-01-01

    We have investigated improvements to PET-MR image registration offered by PET-CT scanning. Ten subjects with suspected soft-tissue sarcomas were scanned with an in-line PET-CT and a clinical MR scanner. PET to CT, CT to MR and PET to MR image registrations were performed using a rigid-body external marker technique and rigid and non-rigid voxel-similarity algorithms. PET-MR registration was also performed using transformations derived from the registration of CT to MR. The external marker technique gave fiducial registration errors of 2.1 mm, 5.1 mm and 5.3 mm for PET-CT, PET-MR and CT-MR registration. Target registration errors were 3.9 mm, 9.0 mm and 9.3 mm, respectively. Voxel-based algorithms were evaluated by measuring the distance between corresponding fiducials after registration. Registration errors of 6.4 mm, 14.5 mm and 9.5 mm, respectively, for PET-CT, PET-MR and CT-MR were observed for rigid-body registration while non-rigid registration gave errors of 6.8 mm, 16.3 mm and 7.6 mm for the same modality combinations. The application of rigid and non-rigid CT to MR transformations to accompanying PET data gives significantly reduced PET-MR errors of 10.0 mm and 8.5 mm, respectively. Visual comparison by two independent observers confirmed the improvement over direct PET-MR registration. We conclude that PET-MR registration can be more accurately and reliably achieved using the hybrid technique described than through direct rigid-body registration of PET to MR

  14. Prospective comparison of MR imaging (1.5 T) and CT detection of small intracranial metastases

    International Nuclear Information System (INIS)

    Dowd, C.F.; Dillon, W.P.; Laxer, K.; Norman, D.; Newton, T.H.

    1987-01-01

    Prior studies indicate lack of MR imaging sensitivity in the evaluation of intractable seizure patients. The authors reviewed MR imaging studies of 15 patients with intractable seizures. High-quality thin-section multiplanar images were obtained with electrocardiographic gating and/or flow compensation techniques and a 1.5-T General Electric Signa unit. Correlation with intracranial electro-encephalography (EEG), CT, and pathology was obtained in all patients. Abnormalities on MR imaging were detected in all but one patient. Pathology revealed MTS in 12 of 15 patients. Other entities included heterotopias and cavernous angiomas. The authors' study indicates that high-resolution, flow-compensated MR imaging is quite sensitive for localization of eleptogenic structural abnormalities and complements EEG

  15. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    Science.gov (United States)

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  16. T2*-weighted image/T2-weighted image fusion in postimplant dosimetry of prostate brachytherapy

    International Nuclear Information System (INIS)

    Katayama, Norihisa; Takemoto, Mitsuhiro; Yoshio, Kotaro

    2011-01-01

    Computed tomography (CT)/magnetic resonance imaging (MRI) fusion is considered to be the best method for postimplant dosimetry of permanent prostate brachytherapy; however, it is inconvenient and costly. In T2 * -weighted image (T2 * -WI), seeds can be easily detected without the use of an intravenous contrast material. We present a novel method for postimplant dosimetry using T2 * -WI/T2-weighted image (T2-WI) fusion. We compared the outcomes of T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based postimplant dosimetry. Between April 2008 and July 2009, 50 consecutive prostate cancer patients underwent brachytherapy. All the patients were treated with 144 Gy of brachytherapy alone. Dose-volume histogram (DVH) parameters (prostate D90, prostate V100, prostate V150, urethral D10, and rectal D2cc) were prospectively compared between T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based dosimetry. All the DVH parameters estimated by T2 * -WI/T2-WI fusion-based dosimetry strongly correlated to those estimated by CT/T2-WI fusion-based dosimetry (0.77≤ R ≤0.91). No significant difference was observed in these parameters between the two methods, except for prostate V150 (p=0.04). These results show that T2 * -WI/T2-WI fusion-based dosimetry is comparable or superior to MRI-based dosimetry as previously reported, because no intravenous contrast material is required. For some patients, rather large differences were observed in the value between the 2 methods. We thought these large differences were a result of seed miscounts in T2 * -WI and shifts in fusion. Improving the image quality of T2 * -WI and the image acquisition speed of T2 * -WI and T2-WI may decrease seed miscounts and fusion shifts. Therefore, in the future, T2 * -WI/T2-WI fusion may be more useful for postimplant dosimetry of prostate brachytherapy. (author)

  17. Automated CT-based segmentation and quantification of total intracranial volume

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar, Carlos; Wahlund, Lars-Olof; Westman, Eric [Karolinska Institute, Department of Neurobiology, Care Sciences and Society (NVS), Division of Clinical Geriatrics, Stockholm (Sweden); Edholm, Kaijsa; Cavallin, Lena; Muller, Susanne; Axelsson, Rimma [Karolinska Institute, Department of Clinical Science, Intervention and Technology, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Simmons, Andrew [King' s College London, Institute of Psychiatry, London (United Kingdom); NIHR Biomedical Research Centre for Mental Health and Biomedical Research Unit for Dementia, London (United Kingdom); Skoog, Ingmar [Gothenburg University, Department of Psychiatry and Neurochemistry, The Sahlgrenska Academy, Gothenburg (Sweden); Larsson, Elna-Marie [Uppsala University, Department of Surgical Sciences, Radiology, Akademiska Sjukhuset, Uppsala (Sweden)

    2015-11-15

    To develop an algorithm to segment and obtain an estimate of total intracranial volume (tICV) from computed tomography (CT) images. Thirty-six CT examinations from 18 patients were included. Ten patients were examined twice the same day and eight patients twice six months apart (these patients also underwent MRI). The algorithm combines morphological operations, intensity thresholding and mixture modelling. The method was validated against manual delineation and its robustness assessed from repeated imaging examinations. Using automated MRI software, the comparability with MRI was investigated. Volumes were compared based on average relative volume differences and their magnitudes; agreement was shown by a Bland-Altman analysis graph. We observed good agreement between our algorithm and manual delineation of a trained radiologist: the Pearson's correlation coefficient was r = 0.94, tICVml[manual] = 1.05 x tICVml[automated] - 33.78 (R{sup 2} = 0.88). Bland-Altman analysis showed a bias of 31 mL and a standard deviation of 30 mL over a range of 1265 to 1526 mL. tICV measurements derived from CT using our proposed algorithm have shown to be reliable and consistent compared to manual delineation. However, it appears difficult to directly compare tICV measures between CT and MRI. (orig.)

  18. Automated CT-based segmentation and quantification of total intracranial volume

    International Nuclear Information System (INIS)

    Aguilar, Carlos; Wahlund, Lars-Olof; Westman, Eric; Edholm, Kaijsa; Cavallin, Lena; Muller, Susanne; Axelsson, Rimma; Simmons, Andrew; Skoog, Ingmar; Larsson, Elna-Marie

    2015-01-01

    To develop an algorithm to segment and obtain an estimate of total intracranial volume (tICV) from computed tomography (CT) images. Thirty-six CT examinations from 18 patients were included. Ten patients were examined twice the same day and eight patients twice six months apart (these patients also underwent MRI). The algorithm combines morphological operations, intensity thresholding and mixture modelling. The method was validated against manual delineation and its robustness assessed from repeated imaging examinations. Using automated MRI software, the comparability with MRI was investigated. Volumes were compared based on average relative volume differences and their magnitudes; agreement was shown by a Bland-Altman analysis graph. We observed good agreement between our algorithm and manual delineation of a trained radiologist: the Pearson's correlation coefficient was r = 0.94, tICVml[manual] = 1.05 x tICVml[automated] - 33.78 (R 2 = 0.88). Bland-Altman analysis showed a bias of 31 mL and a standard deviation of 30 mL over a range of 1265 to 1526 mL. tICV measurements derived from CT using our proposed algorithm have shown to be reliable and consistent compared to manual delineation. However, it appears difficult to directly compare tICV measures between CT and MRI. (orig.)

  19. Response of unirradiated and irradiated PWR fuel rods tested under power-cooling-mismatch conditions

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Quapp, W.J.; Martinson, Z.R.; McCardell, R.K.; Mehner, A.S.

    1978-01-01

    This report summarizes the results from the single-rod power-cooling-mismatch (PCM) and irradiation effects (IE) tests conducted to date in the Power Burst Facility (PBF) at the U.S. DOE Idaho National Engineering Laboratory. This work was performed for the U.S. NRC under contact to the Department of Energy. These tests are part of the NRC Fuel Behavior Program, which is designed to provide data for the development and verification of analytical fuel behavior models that are used to predict fuel response to abnormal or postulated accident conditions in commercial LWRs. The mechanical, chemical and thermal response of both previously unirradiated and previously irradiated LWR-type fuel rods tested under power-cooling-mismatch condition is discussed. A brief description of the test designs is presented. The results of the PCM thermal-hydraulic studies are summarized. Primary emphasis is placed on the behavior of the fuel and cladding during and after stable film boiling. (orig.) [de

  20. Overview and Critical Assessment of the Tensile Properties of unirradiated and irradiated EUROFER97

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; Vandermeulen, W.

    2007-10-15

    Material research represents a crucial issue for the assessment of fusion as a future viable source of energy. Structural materials, in particular, need to show a superior mechanical and chemical behaviour to guarantee the safe operation of the reactor during its whole lifetime, while retaining low activation characteristics to minimise the environmental impact of the produced waste. In this context, specific efforts have been focused for the last twenty years in Europe, Japan and the US, on developing suitable Reduced Activation Ferritic Martensitic (RAFM) steels as candidate structural materials. EUROFER97 has recently emerged in Europe as the reference material for the DEMO design. In the framework of the Long-Term Programme of EFDA (European Fusion Development Agreement), a coordinated effort has been launched aimed at providing a critical assessment of the mechanical and microstructural properties of EUROFER97 in the unirradiated and irradiated conditions, based on the results accumulated since the late 90ies within numerous EFDA tasks.

  1. Predominant CD4 T-lymphocyte tropism of human herpesvirus 6-related virus.

    OpenAIRE

    Takahashi, K; Sonoda, S; Higashi, K; Kondo, T; Takahashi, H; Takahashi, M; Yamanishi, K

    1989-01-01

    Human herpesvirus 6 (HHV-6)-related virus was isolated from CD4+ CD8- and CD3+ CD4+ mature T lymphocytes but could not be isolated from CD4- CD8+, CD4- CD8-, and CD3- T cells in the peripheral blood of exanthem subitum patients. HHV-6-related virus predominantly infected CD4+ CD8+, CD4+ CD8-, and CD3+ CD4+ cells with mature phenotypes and rarely infected CD4- CD8+ cells from cord blood mononuclear cells, which suggested predominant CD4 mature T-lymphocyte tropism of HHV-6-related virus.

  2. The FOXC2 -512C>T variant is associated with hypertriglyceridaemia and increased serum C-peptide in Danish Caucasian glucose-tolerant subjects

    DEFF Research Database (Denmark)

    Yanagisawa, K; Larsen, Lesli Hingstrup; Andersen, G

    2003-01-01

    The transcription factor FOXC2 plays a key role in adipocyte differentiation and the FOXC2 gene is a candidate gene for Type 2 diabetes, obesity and dyslipidaemia. We investigated whether the FOXC2 -512C>T promoter variant is associated with Type 2 diabetes or its intermediary phenotypes in gluco...... tolerant subjects....

  3. Small (≤ 2 cm) hepatocellular carcinoma in patients with chronic liver disease: comparison of gadoxetic acid-enhanced 3.0 T MRI and multiphasic 64-multirow detector CT.

    Science.gov (United States)

    Hwang, J; Kim, S H; Lee, M W; Lee, J Y

    2012-07-01

    To compare the diagnostic performance of gadoxetic acid-enhanced MRI using 3.0 T with that of multiphasic 64-multirow detector CT (MDCT) for the detection of small (≤2 cm) hepatocellular carcinoma (HCC) in patients with chronic liver disease. A total of 54 patients (44 men, 10 women; age range, 33-81 years) with 59 HCCs (≤2 cm in diameter) who underwent both multiphasic (arterial, portal venous, equilibrium) 64-MDCT and gadoxetic acid-enhanced 3.0 T MRI were enrolled in this study. Two observers independently and randomly reviewed the MR and CT images on a lesion-by-lesion basis. The diagnostic performance of these techniques for the detection of HCC was assessed by alternative free-response receiver operating characteristic (ROC) analysis, in addition to evaluating the sensitivity and positive predictive value. For each observer, the areas under the ROC curve were 0.874 and 0.863 for MRI, respectively, as opposed to 0.660 and 0.687 for CT, respectively. The differences between the two techniques were statistically significant for each observer (p0.05). Gadoxetic acid-enhanced 3.0 T MRI shows a better diagnostic performance than that of 64-MDCT for the detection of small (≤2 cm) HCCs in patients with chronic liver disease.

  4. SU-F-T-441: Dose Calculation Accuracy in CT Images Reconstructed with Artifact Reduction Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Ng, C; Chan, S; Lee, F; Ngan, R [Queen Elizabeth Hospital (Hong Kong); Lee, V [University of Hong Kong, Hong Kong, HK (Hong Kong)

    2016-06-15

    Purpose: Accuracy of radiotherapy dose calculation in patients with surgical implants is complicated by two factors. First is the accuracy of CT number, second is the dose calculation accuracy. We compared measured dose with dose calculated on CT images reconstructed with FBP and an artifact reduction algorithm (OMAR, Philips) for a phantom with high density inserts. Dose calculation were done with Varian AAA and AcurosXB. Methods: A phantom was constructed with solid water in which 2 titanium or stainless steel rods could be inserted. The phantom was scanned with the Philips Brillance Big Bore CT. Image reconstruction was done with FBP and OMAR. Two 6 MV single field photon plans were constructed for each phantom. Radiochromic films were placed at different locations to measure the dose deposited. One plan has normal incidence on the titanium/steel rods. In the second plan, the beam is at almost glancing incidence on the metal rods. Measurements were then compared with dose calculated with AAA and AcurosXB. Results: The use of OMAR images slightly improved the dose calculation accuracy. The agreement between measured and calculated dose was best with AXB and image reconstructed with OMAR. Dose calculated on titanium phantom has better agreement with measurement. Large discrepancies were seen at points directly above and below the high density inserts. Both AAA and AXB underestimated the dose directly above the metal surface, while overestimated the dose below the metal surface. Doses measured downstream of metal were all within 3% of calculated values. Conclusion: When doing treatment planning for patients with metal implants, care must be taken to acquire correct CT images to improve dose calculation accuracy. Moreover, great discrepancies in measured and calculated dose were observed at metal/tissue interface. Care must be taken in estimating the dose in critical structures that come into contact with metals.

  5. Evaluation of spiral CT in staging of colon and rectum carcinoma

    International Nuclear Information System (INIS)

    Hundt, W.; Braunschweig, R.; Reiser, M.

    1999-01-01

    The purpose of our study was to evaluate the capability of a subsecond spiral-CT scanner using two contrast medium phases in staging of colorectal cancer. In our study we included 37 patients with proven rectum or colon carcinoma. Spiral CT was performed following tap-water enema of the colon in the arterial and venous phases of contrast medium enhancement. Our results were compared with the findings of pathological examination after surgery. The tumor's size and extension were evaluated in the arterial and venous phases, the lymph nodes in the venous phase of the CT scan. The tumor was in the rectum (n = 14), sigma (n = 11), descending colon (n = 6), and cecum (n = 6). Two-phase spiral CT had a sensitivity of 97.2 % in the arterial phase and 89.1 % in the venous phase in detecting the carcinoma. The staging results were in the arterial phase in 30 of 37 cases (81.0 %) and in the venous phase in 24 of 37 cases (64.8 %) according to pathology. In 27 of 32 patients (84.3 %) lymph nodes were detected. The correct classification of the N-stage was possible in 23 of 34 cases (67.6 %). The combined use of arterial and venous phases in staging of colorectal cancer can improve the T- and N-stage classification in comparison with using only one contrast medium phase. The arterial phase is superior compared with the venous phase for local tumor staging and the venous phase is used for lymph node assessment. (orig.) (orig.)

  6. Differences in MRI findings in cases showing ring-enhancement on a CT scan

    International Nuclear Information System (INIS)

    Tokiwa, Kaichi; Hashimoto, Takashi; Miyasaka, Yoshio; Yada, Kenzoh; Kan, Shinichi; Takagi, Hiroshi.

    1990-01-01

    It is sometimes difficult to differentiate between a brain abscess and a tumor, for both show ring-enhancement on a CT scan. The present authors have studied the benefit of MRI for the differential diagnosis of these two lesions. The subjects of this study were 6 cases of brain abscess and 10 cases of brain tumor, all of them showing ring-enhancement on a CT scan. The MRI findings were compared with those of the CT scan taken at almost the same time, especially focussing on the difference in the ring-enhancement. In 5 out of the 6 cases of brain abscess, T 2 -weighted MRI demonstrated a comparatively thin and homogeneous low-intensity, round rim. In the cases of brain tumor, however, none of the cases demonstrated this typical low-intensity, round rim; rather, in them the rim was thick and irregular. The authors can conclude that those MRI findings can serve as important differential diagnostic findings between brain abscess and tumor; also, MRI may be used as a landmark for terminating the administration of antibiotics in cases of brain abscess. (author)

  7. Interaction of spermine with DNA, vitamin C and bovine serum albumin in the unirradiated and gamma irradiated states

    International Nuclear Information System (INIS)

    Upadhyay, S.N.; Lal, C.; Bhardwaj, R.; Chaturvedi, S.; Chaudhury, N.K.

    2006-01-01

    Structural deformability of spermine with radiation dose (maximum 10 Gy) has been proved. Complex formation of spermine with DNA, vitamin C and BSA took place. Calibration and radiation-induced absorption changes in spermine by ninhydrin reagent has been followed quantitatively. Interaction of vitamin C with DNA and their radiation-induced changes have been reported. Interaction of spermine with DNA in the unirradiated and gamma irradiated states in 10 -3 M phosphate buffer and water have been compared. Addition of spermine and vitamin C to DNA makes DNA structure more condensed. Bovine serum albumin also binds with spermine and protects it from radiation-induced degradation. (author)

  8. Local failure after radical radiotherapy of non-small cell lung cancer in relation to the planning FDG-PET/CT

    DEFF Research Database (Denmark)

    Kandi, M; Hoffmann, L; Sloth Moeller, D

    2018-01-01

    OBJECTIVES: Local recurrence (rec) in lung cancer is associated with poor survival. This study examined whether the pattern of failure is associated with the most PET avid volume in the planning-FDG-PET/CT scan (p-PET/CT). METHODS: 162 consecutive inoperable NSCLC patients (pts) receiving...... 50% of SUVpeak on p-PET/CT and the volume of T-rec was calculated: OF = (SUVp50∩T-rec)/min(SUVp50, T-rec). Similarly for the GTV on the p-CT: OF = (GTV∩T-rec)/min(GTV, T-rec). OF was based on a rigid registration between p-PET/CT and rec-CT with PET guided delineation of T- rec. For lymph nodes (LN...... in these stations; 4R (55%) and 7 (83%). CONCLUSIONS: This study indicates that the most PET active volume on p-PET-CT is a driver for rec at T-site. LN-recurrences predominantly appear in station 2R, 4R, 7 and right hilum. Additional confirmatory studies regarding lymph node mapping and selective lymph node...

  9. In vivo microCT imaging of rodent cerebral vasculature

    International Nuclear Information System (INIS)

    Seo, Youngho; Hasegawa, Bruce H; Hashimoto, Tomoki; Nuki, Yoshitsugu

    2008-01-01

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I tube x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml -1 at 1.2 ml min -1 ) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel (∼85 μm) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid arteries and major cerebral blood vessels

  10. In vivo microCT imaging of rodent cerebral vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Youngho; Hasegawa, Bruce H [Center for Molecular and Functional Imaging, Department of Radiology, University of California, San Francisco, CA 94143 (United States); Hashimoto, Tomoki; Nuki, Yoshitsugu [Center for Cerebrovascular Research, Department of Anesthesia and Perioperative Care, University of California, San Francisco, CA 94143 (United States)], E-mail: youngho.seo@radiology.ucsf.edu

    2008-04-07

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I{sub tube} x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml{sup -1} at 1.2 ml min{sup -1}) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel ({approx}85 {mu}m) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid

  11. Frequency of adult type-associated lactase persistence LCT-13910C/T genotypes in the Czech/Slav and Czech Roma/Gypsy populations

    Directory of Open Access Journals (Sweden)

    Jaroslav A. Hubácek

    2017-05-01

    Full Text Available Abstract Lactase non-persistence (leading to primary lactose intolerance is a genetically dependent inability to digest lactose in adulthood. As part of the human adaptation to dairying, the human lactase LCT-13910C/T mutation (which propagates adult expression of lactase developed, spread and participated in the adaptation to dairying. This variant is associated with lactase activity persistence, and its carriers are able to digest lactose. We compared the frequencies of lactase 13910C/T (rs4988235 genotypes in Czechs/Slavs (N = 288 and Czech Gypsies/Roma (N = 300, two ethnically different groups where this polymorphism has not yet been analysed. Allelic frequencies significantly differed between the populations (p < 0.0001. In Czechs/Slavs, the lactase persistence T allele was present in 76% of the individuals, which is in agreement with frequencies among geographically neighbouring populations. In the Czech Gypsy/Roma population, only 27% of the adults were carriers of at least one lactase persistence allele, similar to the Indian population. In agreement with this result, dairy product consumption was reported by 70.5% of Czechs/Slavs and 39.0% of the Czech Gypsy/Roma population. Both in the Czech Gypsy/Roma and in the Czech/Slavs populations, the presence of carriers of the lactase persistence allele was similar in subjects self-reporting the consumption of unfermented/fresh milk, in comparison to the others.

  12. Phosphoproteomics Reveals Regulatory T Cell-Mediated DEF6 Dephosphorylation That Affects Cytokine Expression in Human Conventional T Cells

    KAUST Repository

    Joshi, Rubin N.

    2017-09-25

    Regulatory T cells (Tregs) control key events of immune tolerance, primarily by suppression of effector T cells. We previously revealed that Tregs rapidly suppress T cell receptor (TCR)-induced calcium store depletion in conventional CD4CD25 T cells (Tcons) independently of IP levels, consequently inhibiting NFAT signaling and effector cytokine expression. Here, we study Treg suppression mechanisms through unbiased phosphoproteomics of primary human Tcons upon TCR stimulation and Treg-mediated suppression, respectively. Tregs induced a state of overall decreased phosphorylation as opposed to TCR stimulation. We discovered novel phosphosites (T595_S597) in the DEF6 (SLAT) protein that were phosphorylated upon TCR stimulation and conversely dephosphorylated upon coculture with Tregs. Mutation of these DEF6 phosphosites abrogated interaction of DEF6 with the IP receptor and affected NFAT activation and cytokine transcription in primary Tcons. This novel mechanism and phosphoproteomics data resource may aid in modifying sensitivity of Tcons to Treg-mediated suppression in autoimmune disease or cancer.

  13. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    International Nuclear Information System (INIS)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee

    2016-01-01

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone

  14. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2016-08-15

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone.

  15. Prospective evaluation of MRI, 11C-acetate PET/CT and contrast-enhanced CT for staging of bladder cancer

    International Nuclear Information System (INIS)

    Vargas, H.A.; Akin, O.; Schöder, H.; Olgac, S.; Dalbagni, G.; Hricak, H.; Bochner, B.H.

    2012-01-01

    Purpose: To prospectively evaluate the diagnostic performance of magnetic resonance imaging (MRI), 11 C-acetate positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT for bladder cancer staging, using whole-mount pathologic review of radical cystectomy and pelvic lymph node specimens as the reference standard. Materials and methods: The institutional review board approved this prospective study, which was compliant with the Health Insurance Portability and Accountability Act. Written informed consent was obtained from 16 patients with histologically confirmed bladder cancer who underwent MRI, 11 C-acetate PET/CT and contrast-enhanced CT before radical cystectomy and pelvic lymph node dissection. Before imaging 4/16 patients had received intravesical Bacillus Calmette-Guérin treatment, 6 had received systemic chemotherapy, 3 had received both and 3 had received neither. Measures of diagnostic performance including accuracy, sensitivity and specificity were estimated separately for each imaging modality. Results: MRI correctly staged 56% of patients (9/16), overstaged 38% (6/16) and understaged 6% (1/16). CT correctly staged 50% of patients (8/16), overstaged 44% (7/16) and understaged 6% (1/16). In 9 patients, 11 C-acetate PET/CT showed uptake within the bladder wall; the uptake was true-positive in 7 patients and false-positive in 2 patients. Of the remaining 7 patients, 5 had true-negative and 2 had false-negative PET/CT results for cancer in the bladder wall. For all modalities, staging accuracy was reduced in patients with a history of prior intravesical and/or systemic chemotherapy. Conclusion: In staging bladder cancer, MRI, 11 C-acetate PET/CT and CT displayed similar levels of accuracy. For all modalities, a history of intravesical and/or systemic chemotherapy affected staging accuracy.

  16. The correlation of CT perfusion imaging with microvessel density and vascular endothelial growth factor in hepatic alveolar echinococcosis

    International Nuclear Information System (INIS)

    Wang Jing; Ren Bo; Liu Wenya; Wen Hao; Qing Song; Xie Weidong; Sun Yajing; Wang Haitao

    2011-01-01

    Objective: To explore the correlation of CT perfusion imaging with microvessel density (MVD) and vascular endothelial growth factor (VEGF) in hepatic alveolar echinococcosis (HAE). Methods: Multi-slice spiral CT perfusion imaging was performed in 27 patients with HAE. Time-density curves(TDC) of the HAE peripheral area was drawn from the region of interest (ROI) with perfusion functional software. CT perfusion parameters including blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) were calculated. MVD and VEGF expression of pathological specimens were examined by immunohistochemical staining with anti-CD34, anti-VEGF monoclonal antibody. The CT perfusion parameters, MVD and VEGF were compared in different types of TDC with t test. The correlation of CT perfusion parameters with MVD and VEGF were analyzed with Spearman test. Results: In this group, 21 cases which TDC lower than that of the liver were classified as type Ⅰ, the others 6 cases TDC higher than the liver were of type Ⅱ TDC. TDC perfusion parameters of the two types were as follows, BF: (111.7±27.6), (158.9±39.5) ml · 100 g -1 · min -1 , BV: (15.1±6.2) , (26.8±8.4) ml/100 g, MTT: (7.0±4.4), (7.7±3.1) s, PS: (51.7±17.3), (51.0±20.5) ml ·100 g -1 · min -1 . The significant differences of BF, BV and MVD [(20.5±5.4)/HP, (37.2±7.5)/HP, respectively] were found between two types (t=-7.897, -18.783, -5.223, P 0.05). The correlation was found between the MVD and BF and BV in the type Ⅱ TDC group (r=0.789 and 0.878, respectively) and no correlation was found between MVD and each CT perfusion parameters in the type Ⅰ TDC group (P>0.05). There was no correlation between the VEGF expression and CT perfusion parameters in two types of TDC (P>0.05). Conclusion: CT perfusion imaging with different type of TDC reflected different situation of angiogenesis in HAE peripheral area, which could be a potential technique to illustrate the

  17. 18F-FAZA PET/CT in the Preoperative Evaluation of NSCLC: Comparison with 18F-FDG and Immunohistochemistry.

    Science.gov (United States)

    Mapelli, Paola; Bettinardi, Valentino; Fallanca, Federico; Incerti, Elena; Compierchio, Antonia; Rossetti, Francesca; Coliva, Angela; Savi, Annarita; Doglioni, Claudio; Negri, Giampiero; Gianolli, Luigi; Picchio, Maria

    2018-01-01

    To assess the capability of 18F-FAZA PET/CT in identifying intratumoral hypoxic areas in early and locally advanced non-small cell lung cancer (NSCLC) patients and to compare 18FFAZA PET/CT with 18F-FDG PET/CT and histopathological biomarkers and to investigate whether the assessment of tumour to blood (T/B) and tumour to muscle (T/M) ratios provide comparable information regarding the hypoxic fractions of the tumour. Seven patients with NSCLC were prospectively enrolled (3 men, 4 women; median age: 71 years; range 63-80). All patients underwent to 18F-FDG PET/CT and 18F-FAZA PET/CT before surgery. Maximum standardized uptake value (SUVmax) was used to evaluate 18FFDG PET/CT images, while 18F-FAZA PET/CT images have been interpreted by using tumour-toblood (T/B) and tumour-to-muscle (T/M) ratio. Surgery was performed in all patients; immunohistochemical analysis for hypoxia biomarkers was performed on histologic tumor samples. All lung lesions showed intense 18F-FDG uptake (mean SUVmax: 7.35; range: 2.35-25.20). A faint 18F-FAZA uptake was observed in 6/7 patients (T/B < 1.2) while significant uptake was present in the remaining 1/7 (T/B and T/M=2.24). On both 2 and 4 h imaging after injection, no differences were observed between T/M and T/B (p=0.5), suggesting that both blood and muscle are equivalent in estimating the background activity for image analysis. Immunohisotchemical analysis showed low or absent staining for hypoxia biomarkers in 3 patients (CA-IX and GLUT-1: 0%; HIF-1α: mean 3.3%; range 0-10). Two patients showed staining for HIF-1α of 5%, with CA-IX being 60% and 30%, respectively and GLUT-1 being 30% and 80%, respectively; in 1/7 HIF-1α was 10%, CA-IX was 50% and GLUT-1 was 90%. In one patient a higher percentage of HIF-1α and CA-IX (20% and 70%, respectively) positive cells was present, with GLUT-1 being 30%. To the best of our knowledge, this is the first paper assessing hypoxia and glucose metabolism in comparison with immunohistochemistry

  18. Phantom study on three-dimensional target volume delineation by PET/CT-based auto-contouring

    International Nuclear Information System (INIS)

    Zhang, Tiejiao; Sakaguchi, Yuichi; Mitsumoto, Katsuhiko; Mitsumoto, Tatsuya; Sasaki, Masayuki; Tachiya, Yosuke; Ohya, Nobuyoshi

    2010-01-01

    The aim of this study was to determine an appropriate threshold value for delineation of the target volume in positron emission tomography (PET)/CT and to investigate whether we could delineate a target volume by phantom studies. A phantom consisted of six spheres (φ10-37 mm) filled with 18 F solution. Data acquisition was performed PET/CT in non-motion and motion status with high 18 F solution and in non-motion status with low 18 F solution. In non-motion phantom experiments, we determined two types of threshold value, an absolute SUV (T SUV ) and a percentage of the maximum SUV (T % ). Delineation using threshold values was applied for all spheres and for selected large spheres (a diameter of 22 mm or larger). In motion phantom experiments, data acquisition was performed in a static mode (sPET) and a gated mode (gPET). CT scanning was performed with helical CT (HCT) and 4-dimentional CT (4DCT). The appropriate threshold values were aT % =27% and aT SUV =2.4 for all spheres, and sT % =30% and sT SUV =4.3 for selected spheres. For all spheres in sPET/HCT in motion, the delineated volumes were 84%-129% by the aT % and 34%-127% by the aT SUV . In gPET/4DCT in motion, the delineated volumes were 94-103% by the aT % and 51-131% by the aT SUV . For low radioactivity spheres, the delineated volumes were all underestimated. A threshold value of T % =27% was proposed for auto-contouring of lung tumors. Our results also suggested that the respiratory gated data acquisition should be performed in both PET and CT for target volume delineation. (author)

  19. NMR characteristics of low-grade glioma. Comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Asato, Reinin; Tokuriki, Yasuhiko; Nakano, Yoshihisa; Itoh, Harumi; Torizuka, Kanji; Ueda, Tohru; Yamashita, Junkoh; Handa, Hajime

    1985-08-01

    Sixteen low-grade gliomas were evaluated both with nuclear magnetic resonance (NMR) imaging and with computed tomography (CT). In 13 cases (81%), the NMR images were much better in tissue contrast than the contrast-enhanced CT images. The tumors were shown as well-circumscribed oval lesions in the NMR, though they appeared as ill-defined, irregular, low-attenuation areas in the CT. The extent of the lesion, which was supposed to represent the active tumor tissue, was greater in the NMR than in the CT, because NMR tissue parameters (T/sub 1/, T/sub 2/) are more sensitive to pathological changes in brain tissue than is the X-ray attenuation coefficient. Though, in an optic glioma and a brain-stem astrocytoma, the CT with contrast enhancement displayed the contour of the mass as well as did NMR, it was inferior to the NMR in showing the cephalocaudal extension of the tumors. Calcification does not give a proton NMR signal under the present measuring conditions; thus the calcified cystic wall of a hypothalamic astrocytoma was displayed only in the CT images. In conclusion, the NMR imaging was apparently superior to contrast-enhanced CT in demonstrating the lesions due to low-grade glioma.

  20. TRIPLE PHASE SPIRAL C.T. IN THE EVALUATION OF HEPATIC MASSES

    Directory of Open Access Journals (Sweden)

    Prasad

    2015-10-01

    classified broadly in to ; 1. Blobular enhancement seen in cases of hemangiomas . 2. Homogeneous hypodense (a ttenuation value less than 25 H.U . 3. Homogeneous hypodense (solid . 4. Heterogeneous hypodense . 5. Hemogeneous hyperdense . 6. Heterogeneous hyperdense in cases of metastases. RESULTS: The relative enhancement of liver during hepatic arterial phase (HAP portal venous phase (PVP and equilibrium phase (EP was obtained satisfactorily in all patients included in the study. Arterial phase images showed intensely opacified hepatic arterial system. In some cases portal veins showed enhancement when the imaging extended into late arterial phase period, however the liver parenchymal enhancement was well below the enhancement achieved is portal venous phases. Average parenchymal attenuation was baseline (NECT attenuation + 10 - 20H.U. Portal venous phase image showed peak enhancement of liver parenchyma. The portal vein enhancement at portahepatis was more intense compared to arterial system is this phase. Liver parenchyma attained peak attenuati on during portal venous phase which was approximately 40- 50 H.U above baseline (NECT lives attenuation. During equilibrium phase, the vascular spaces and parenchyma could be distinguished, but with very less conspicuity compared to hepatic arterial phase and portal venous phase images. Average liver attenuation fell back to 25 – 30 H.U above baseline value, during this phase. Total of 572 lesions were detected is 50patients of these 531 lesions in 36 patients were malignant and 41 lesions is 14 patients we re beings. INTERPRETATION AND CONCLUSION: Based on our study and on reviewing the literature. Hepatic arterial phase and portal venous phase are the most useful phases among triple phase spiral CT. Hepatic arterial phase and portal venous phase together ca n confidently charact er ize and differentiate hypervascular malignant lesions (HCC or hypervacular metastases from most common benign lesions, with 3 specific patterns of

  1. CT evaluation of thymus in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Guk Hee [Insung Hospital, Chuncheon (Korea, Republic of); Kang, Eun Young; Lee, Nam Joon; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1989-12-15

    The relationship between myasthenia gravis and the thymus was well establish and myasthenia gravis occurs in the presence of thymic hyperplasia or thymoma or occasionally in histologically normal thymus. Since not every patients with myasthenia gravis is a candidate for thymectomy, unless a thymoma is present, the differentiation of normal and hyperplastic thymus from thymoma becomes important. Authors reviewed retrospectively clinical records and chest CT scans of 18 patients with myasthenia gravis who underwent thymectomy during recent 5 years, to evaluate the role of CT scan. The results were as follows. 1 Of total 18 cases, 5 cases had normal thymus, 6 cases had thymic hyperplasia, 4 cases had benign thymoma and 3 cases had malignant thymoma. 2. Of 5 cases of normal thymus, no false positive cases were noted in CT scan. 3. Of 6 cases of thymic hyperplasia, CT findings were normal except 1 cases of thickened left thymic lobe. 4. Of 7 cases of thymoma, no false negative cases were noted in CT scan. 5. CT findings of benign thymoma were round or oval shaped, discrete, slightly enhancing soft tissue mass in anterior mediastinum. 6. CT findings of malignant thymoma were lobulated contoured, infiltrative, soft tissue mass lesion in anterior mediastinum with calcifications, pleural tumor implants, and SVC compression. CT yielded valuable information on differential diagnosis of thymoma, thymic hyperplasia and normal thymus. Also CT was a highly sensitive method in the detection of thymoma and determining the extent and invasiveness.

  2. CT evaluation of thymus in myasthenia gravis

    International Nuclear Information System (INIS)

    Kim, Guk Hee; Kang, Eun Young; Lee, Nam Joon; Suh, Won Hyuck

    1989-01-01

    The relationship between myasthenia gravis and the thymus was well establish and myasthenia gravis occurs in the presence of thymic hyperplasia or thymoma or occasionally in histologically normal thymus. Since not every patients with myasthenia gravis is a candidate for thymectomy, unless a thymoma is present, the differentiation of normal and hyperplastic thymus from thymoma becomes important. Authors reviewed retrospectively clinical records and chest CT scans of 18 patients with myasthenia gravis who underwent thymectomy during recent 5 years, to evaluate the role of CT scan. The results were as follows. 1 Of total 18 cases, 5 cases had normal thymus, 6 cases had thymic hyperplasia, 4 cases had benign thymoma and 3 cases had malignant thymoma. 2. Of 5 cases of normal thymus, no false positive cases were noted in CT scan. 3. Of 6 cases of thymic hyperplasia, CT findings were normal except 1 cases of thickened left thymic lobe. 4. Of 7 cases of thymoma, no false negative cases were noted in CT scan. 5. CT findings of benign thymoma were round or oval shaped, discrete, slightly enhancing soft tissue mass in anterior mediastinum. 6. CT findings of malignant thymoma were lobulated contoured, infiltrative, soft tissue mass lesion in anterior mediastinum with calcifications, pleural tumor implants, and SVC compression. CT yielded valuable information on differential diagnosis of thymoma, thymic hyperplasia and normal thymus. Also CT was a highly sensitive method in the detection of thymoma and determining the extent and invasiveness

  3. The CT diagnose of pleural metastasis tumour

    International Nuclear Information System (INIS)

    Chen Liqun; Han Kaibin; Pan Heng; Huang Xiaoru; Zhou Bingcao; Huang Yuehua

    2007-01-01

    Objective: To discuss the CT characteristic of pleural metastasis tumour,enhance the diagnostic level of pleural metastasis tumour. Methods: Review 30 cases which have been performed CT scan in our hospital during March 2002 to June 2003, which have been approved to pleural metastasis tumour by pathology and clinic. Make use of GE Hispeed.zx/i spiral CT,10mm thickness,10mm increment, l.5 pitch, some of them use 10mm or high resolution mode. All cases have been performed normal scan, 25 cases with contrast scan. Results: The CT representation of pleural metastasis tumour are encapsulated pleural effusion with irregular pleural thickening(56.6%), nodular pleural thickening(46.6%), pleural masses (13.3%), pneumothorax (3.3%), etc. Encapsulated pleural effusion and nodular pleural thickening are 76.6%, use contrast mode to scan pleural pathological changes enhance upon middle level, CT value increment > 20HU, there are 66.6% cases with other chest metastasis symptom, 73.3% primary lesion are pulmonary cancer, and 20% no primary lesion are found. Conclusion: Combine primary lesion history and other chest metastasis symptom, Spiral CT examination can differentiate most of pleural metastasis tumour, but it is difficult to differentiate the cases between with a little pleural effusion or light band pleural thickening and reactive alteration. (authors)

  4. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    International Nuclear Information System (INIS)

    Cornelis, F.; Takaki, H.; Laskhmanan, M.; Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G.

    2015-01-01

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy

  5. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    Energy Technology Data Exchange (ETDEWEB)

    Cornelis, F.; Takaki, H. [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States); Laskhmanan, M. [Perfint Healthcare Inc (India); Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G., E-mail: srimaths@mskcc.org [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States)

    2015-10-15

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.

  6. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  7. comparison of clinical features and CT findings between atypical thymoma and thymic carcinoma

    International Nuclear Information System (INIS)

    Wang Xiangyang; Tan Ye; Chen Juan; Wei Jiahu; Pan Jishun; Du Jun; Zhou Cheng

    2011-01-01

    Objective: To investigate the differences and the similarities of clinical presentations and CT features between type B3 thymoma (atypical thymoma) and type C thymoma (thymic carcinoma) in the WHO classification of thymic epithelial tumors. Methods: Complete CT findings of thirty cases of type B3 and seventeen cases of type C thymic epithelial tumors confirmed by histopathology according to WHO 2004 Classification System and clinical features including the prognosis of each case were reviewed retrospectively. Statistical analyses of the data for the age and the long diameter were performed with Independent-Samples t test between the two groups. Statistical analysis for gender, association with myasthenia gravis, method of the operation, contours, shapes, calcification,necrosis, enhancement pattern of the tumors on CT, presence of mediastinal lymphadenopathy, invasion of mediastinal fat, chest wall, pericardium, great vessel, pleural mediastinum, metastasis to the plural, pleural effusion, distant metastasis were performed with Fisher exact test. Kaplan-Meier method was employed for survival analysis. Results: Clinical data: the average age of type B3 group was significantly younger (t=-2.905, P=0.006). 90.0% (27/30) of patients in type B3 group were complicated by myasthenia gravis, while only 5.9% (1/17) of patients in type C group were complicated by myasthenia gravis. The difference between the two groups was statistically significant (P=0.000). The ratio of complete resection of type B3 group (80.0%) was significantly higher than that in type C group (P=0.001), 70.6% (12/17) of patients in type C group died within 2 years after surgical resection, while only 20.0% (6/30) of patients in type B3 group died within one to nine years after surgical resection. Three years' survival ratio of C group was 29.4%, and five years' survival ratio of C group was lower than 14.7%, which was significantly lower than B3 group five years' survival ratio was 94.7%), which was

  8. An experimental study of exogenous lipoid pneumonia : sequential changes in high-resolution CT and MR findings

    International Nuclear Information System (INIS)

    Kim, Kyeong Ah; Kang, Eun Young; Kim, Dae Hyun; Park, Sang Woo; Choi, Jeong Cheol; Kim, Ae Ree; Kim, Han Kyum; Cha, In Ho

    1999-01-01

    To evaluate sequential changes in high-resolution CT(HRCT) and MR findings of exogenous lipoid pneumonia in rabbits and to compare the radiologic and histopathologic findings. A single endobronchial administration of shark liver oil(0.5 or 1 ml/kg of body weight) was given to 25 rabbits. HRCT scans were obtained immediately(n=17), at 1 day(n=14), 3 days(n=10), 1 week(n=15), 2 weeks(n=10), 4 weeks(n=9), 6 weeks(n=5), 8 weeks(n=6), 10 weeks(n=4), 12 weeks(n=2), 14 weeks(n=3), and 16 weeks(n=2) after administration. Changes in distribution, extent, and attenuation were assessed on HRCT scans. MR scans were obtained immediately(n=12), at 1 day(n=9), 3 days(n=9), 1 week(n=15), 2 weeks(n=9), 4 weeks(n=11), 6 weeks(n=5), 8 weeks(n=7), 10 weeks(n=3), 14 weeks(n=3), and at 16 weeks(n=2) after administration. Changes in distribution, extent, and signal intensity were assessed on MR scans. In 16 rabbits, CT and MR findings were compared with histopatholo-gic findings obtained in the same plane. HRCT findings included consolidation with air-bronchogram, ground-glass attenuation and fat attenuation within the lesion at earlier stages(immediate-2 weeks). The extent of lesions was greatest at 1 week, and was then seen to gradually decrease on follow-up CT scans. T1-weighted MR images(T1WI) showed high or intermediate signal intensity(SI) at earlier stages and intermediate SI at later stages, while T2-weighted MR images(T2WI) showed high SI at both earlier and later stages. Histopathologic correlation showed that ground-glass attenuation and consolidation on HRCT reflected intraalveolar lipid-laden macrophages, cuboidal metaplasia of alveolar epithelial cells, and alveolar septal widening with inflammatory cell infiltration. Maximal infiltration of oil in the lung correlated closely with the peak low-attenuation seen on CT scans and the high signal intensity seen on T1WI. Shark liver oil-induced exogenous lipoid pneumonia in rabbits is reliably diagnosed by HRCT and MR during

  9. Peripheral Blood CCR4+CCR6+ and CXCR3+CCR6+ CD4+ T Cells Are Highly Permissive to HIV-1 Infection

    OpenAIRE

    Gosselin, Annie; Monteiro, Patricia; Chomont, Nicolas; Diaz-Griffero, Felipe; Said, Elias A.; Fonseca, Simone; Wacleche, Vanessa; El-Far, Mohamed; Boulassel, Mohamed-Rachid; Routy, Jean-Pierre; Sekaly, Rafick-Pierre; Ancuta, Petronela

    2009-01-01

    There is limited knowledge on the identity of primary CD4+ T cell subsets selectively targeted by HIV-1 in vivo. In this study, we established a link between HIV permissiveness, phenotype/homing potential, and lineage commitment in primary CD4+ T cells. CCR4+CCR6+, CCR4+CCR6−, CXCR3+CCR6+, and CXCR3+CCR6T cells expressed cytokines and transcription factors specific for Th17, Th2, Th1Th17, and Th1 lineages, respectively. CCR4+CCR6+ and CXCR3+CCR6+ T cells expressed the HIV coreceptors CCR5 a...

  10. The correlation of preoperative CT, MR imaging, and clinical staging (FIGO) with histopathology findings in primary cervical carcinoma

    International Nuclear Information System (INIS)

    Oezsarlak, Oe.; Schepens, E.; Corthouts, B.; Beeck, B.O. de; Parizel, P.M.; De Schepper, A.M.; Tjalma, W.; Marck, E. van

    2003-01-01

    The aim of this study was to compare the preoperative findings of abdominal/pelvic CT and MRI with the preoperative clinical International Federation of Obstetrics and Gynecology (FIGO) staging and postoperative pathology report in patients with primary cancer of the cervix. Thirty-six patients with surgical-pathological proven primary cancer of the cervix were retrospectively studied for preoperative staging by clinical examination, CT, and MR imaging. Studied parameters for preoperative staging were the presence of tumor, tumor extension into the parametrial tissue, pelvic wall, adjacent organs, and lymph nodes. The CT was performed in 32 patients and MRI (T1- and T2-weighted images) in 29 patients. The CT and MR staging were based on the FIGO staging system. Results were compared with histological findings. The group is consisted of stage 0 (in situ):1, Ia:1, Ib:8, IIa:2, IIb:12, IIIa:4, IVa:6, and IVb:2 patients. The overall accuracy of staging for clinical examination, CT, and MRI was 47, 53, and 86%, respectively. The MRI incorrectly staged 2 patients and did not visualize only two tumors; one was an in situ (stage-0) and one stage-Ia (microscopic) disease. The MRI is more accurate than CT and they are both superior to clinical examination in evaluating the locoregional extension and preoperative staging of primary cancer of the cervix. (orig.)

  11. Study on the behavior of unirradiated light water reactor fuel with iodine-127 under the reactivity initiated accident (RIA) conditions

    International Nuclear Information System (INIS)

    Sasajima, Hideo; Yanagisawa, Kazuaki; Kanazawa, Hiroyuki

    1988-07-01

    In a light water reactor fuel, a stress arised from pellet-cladding interaction (PCI) will have possibility to cause stress corrosion claddling (PCI failure) under an environment of corrosive fission product ; line iodine. A pulse irradiation experiment by NSRR was carried out to examine whether or not an unirradiated NSRR standard fuel rod in which 1.3 mg (33 x 10 -6 g/cm 2 ) of iodine was artificially filled could cause the PCI failure. Obtained results are: (1) The fuel rods with iodine did not fail both at deposited energy levels of 268 and 280 cal/g · UO 2 . On the other hand, the fuel rods without iodine failed at the same energy levels due to thinning of the cladding wall thickness. Within this experimental scope, PCI-failure did not occur on iodine filled fuel rods. (2) At a periphery of the fuel pellet of iodine filled rod, an uniform torus ring was formed. The torus ring consisted of an equi-axed large grains at 268 cal/g · UO 2 and a columnar ones at 280 cal/g · UO 2 . The torus ring was not formed in the fuel without iodine. (author)

  12. Heterotopic grey matter: Ct vs. MRI

    International Nuclear Information System (INIS)

    Hosten, N.; Schoerner, W.

    1989-01-01

    Heterotopic grey matter is a rare cause of seizures. While lesions appear suspicious on CT because of equidensity to cortex, MR imaging can establish the diagnosis by demonstrating same signal intensity of heterotopia and grey matter on T 1 - and T 2 -weighted as well as inversion-recovery sequences. (orig.) [de

  13. Low cycle fatigue properties of neutron irradiated solid HIP 316L(N). ITER Task T214, NET deliverable GB6 ECN-5

    International Nuclear Information System (INIS)

    Rensman, J.; Van Osch, E.V.; Tjoa, G.L.; Boskeljon, J.; Van Hoepen, J.

    1998-05-01

    The Low Cycle Fatigue (LCF) properties of neutron irradiated Hot Isostatically Pressed (HIP) joints of type 316L(N) stainless steel (heat PM-130) have been measured, as well as the LCF properties of reference 316L(N)-ERHII. Cylindrical LCF test specimens of 3 mm diameter were irradiated in the High Flux Reactor (HFR) in Petten, The Netherlands, simulating the first wall conditions of future fusion reactors by a combination of high displacement damage with proportional amounts of helium. The solid HIP specimens were irradiated up to a target dose level of 5 dpa at a temperature of 550K. The damage levels realised range from 3.0 to 4.4 dpa, with helium contents up to 41 appm. Testing temperature was equal to the irradiation temperature: 550K. The report contains the experimental conditions and summarises the results, which are given in terms of first cycle stress, the peak stress, the number of cycles where the peak stress is reached, the stress at half life and the plastic strain at half life, and the total number of cycles to failure, N f . The main conclusions are that the unirradiated solid-HIP materials has the same LCF properties as unirradiated 316L(N)-ERHII plate material. The neutron irradiation induces both hardening and reduction of fatigue life. The bond does not seem to have any effect on the fatigue properties for the unirradiated solid HIP 316L(N), whereas a combined effect of irradiation and the bond cannot be established. No failures related to debonding of the joint were observed for the tests. 7 refs

  14. CT after transsphenoidal surgery

    International Nuclear Information System (INIS)

    Tazawa, Satoru

    1991-01-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author)

  15. CT after transsphenoidal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Tazawa, Satoru [Tohoku Univ., Sendai (Japan). School of Medicine

    1991-03-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author).

  16. New horizons in cardiac CT

    International Nuclear Information System (INIS)

    Harder, A.M. den; Willemink, M.J.; Jong, P.A. de; Schilham, A.M.R.; Rajiah, P.; Takx, R.A.P.; Leiner, T.

    2016-01-01

    Until recently, cardiovascular computed tomography angiography (CCTA) was associated with considerable radiation doses. The introduction of tube current modulation and automatic tube potential selection as well as high-pitch prospective ECG-triggering and iterative reconstruction offer the ability to decrease dose with approximately one order of magnitude, often to sub-millisievert dose levels. In parallel, advancements in computational technology have enabled the measurement of fractional flow reserve (FFR) from CCTA data (FFR_C_T). This technique shows potential to replace invasively measured FFR to select patients in need of coronary intervention. Furthermore, developments in scanner hardware have led to the introduction of dual-energy and photon-counting CT, which offer the possibility of material decomposition imaging. Dual-energy CT reduces beam hardening, which enables CCTA in patients with a high calcium burden and more robust myocardial CT perfusion imaging. Future-generation CT systems will be capable of counting individual X-ray photons. Photon-counting CT is promising and may result in a substantial further radiation dose reduction, vastly increased spatial resolution, and the introduction of a whole new class of contrast agents.

  17. {sup 18F} FDG Uptake of Human Testis on PET/CT: Correlation with Age, Sex Hormones, and Vasectomy

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Eo, Jae Sun; Lee, Jong Jin; Chung, June Key; Lee, Dong Soo; Lee, Myung Chul [Seoul National Univ. Hospital, Seoul (Korea, Republic of)

    2011-12-15

    The purpose of this study was to evaluate glucose metabolism of normal human testis on {sup 18F} FDG PET/CT and to assess possible correlation among age, the serum levels of sex hormones, and vasectomy. {sup 18F} FDG PET/CT was performed in 66 normal healthy men (50.8{+-}13.6 years, range 22-81), and mean standard uptake values (SUV) of {sup 18F} FDG in testis and adductor muscle were measured. Testis muscle SUV ratios (T/M ratios) were calculated. Serum levels of total testosterone, free testosterone, estradiol, and of sex hormone binding globulin (SHBG) were measured. We searched for correlations between T/M ratios and age and the serum concentrations of sex hormones. {sup 18F} FDG PET/CT was also performed in 32 vasectomized men (55.7{+-}7.8 years, range 38-71) and 52 nonvasectomized men (55.4{+-}11.6 years, range 37-72). Mean SUVs of testis and adductor muscle were measured, and T/M ratios were calculated. A significant age related decline was found in T/M ratio (r=-0.509, p<0.0001). Serum levels of total testosterone and free testosterone were also found to be positively correlated with T/M ratio (r=-0.427, p=0.0003; r=0.435, p=0.0003, respectively). The mean SUV and T/M ratio of vasectomized men were significantly lower than those of nonvasectomized men (p<0.0378 and p=0.0001, respectively). Glucose metabolism in the testis in an adult population was found to be correlated with age, serum sex hormone level, and vasectomy history. These results indicate that testicular {sup 18F} FDG uptake may have attributed to testicular function and testicular histology. Our findings may have important implications for the interpretation of testicular {sup 18F} FDG uptake in the normal adult population.

  18. Diagnostic Yield of Recommendations for Chest CT Examination Prompted by Outpatient Chest Radiographic Findings

    Science.gov (United States)

    Harvey, H. Benjamin; Gilman, Matthew D.; Wu, Carol C.; Cushing, Matthew S.; Halpern, Elkan F.; Zhao, Jing; Pandharipande, Pari V.; Shepard, Jo-Anne O.

    2015-01-01

    Purpose To evaluate the diagnostic yield of recommended chest computed tomography (CT) prompted by abnormalities detected on outpatient chest radiographic images. Materials and Methods This HIPAA-compliant study had institutional review board approval; informed consent was waived. Reports of all outpatient chest radiographic examinations performed at a large academic center during 2008 (n = 29 138) were queried to identify studies that included a recommendation for a chest CT imaging. The radiology information system was queried for these patients to determine if a chest CT examination was obtained within 1 year of the index radiographic examination that contained the recommendation. For chest CT examinations obtained within 1 year of the index chest radiographic examination and that met inclusion criteria, chest CT images were reviewed to determine if there was an abnormality that corresponded to the chest radiographic finding that prompted the recommendation. All corresponding abnormalities were categorized as clinically relevant or not clinically relevant, based on whether further work-up or treatment was warranted. Groups were compared by using t test and Fisher exact test with a Bonferroni correction applied for multiple comparisons. Results There were 4.5% (1316 of 29138 [95% confidence interval {CI}: 4.3%, 4.8%]) of outpatient chest radiographic examinations that contained a recommendation for chest CT examination, and increasing patient age (P recommendation for chest CT examination. Of patients within this subset who met inclusion criteria, 65.4% (691 of 1057 [95% CI: 62.4%, 68.2%) underwent a chest CT examination within the year after the index chest radiographic examination. Clinically relevant corresponding abnormalities were present on chest CT images in 41.4% (286 of 691 [95% CI: 37.7%, 45.2%]) of cases, nonclinically relevant corresponding abnormalities in 20.6% (142 of 691 [95% CI: 17.6%, 23.8%]) of cases, and no corresponding abnormalities in 38

  19. Pulmonary CT angiography: optimization of contrast enhancement technique

    International Nuclear Information System (INIS)

    Ma Lianju; Tang Guangjian; Fu Jiazhen

    2012-01-01

    Objective: To derive and evaluate the formula of exactly calculating the contrast dosage used during pulmonary CT angiography (CTPA). Methods: Time density curves in 27 patients who underwent CTPA were collected and analyzed,the formula for calculating contrast dosage during CTPA was derived. 68 patients suspected of pulmonary embolism (PE) clinically but no PE on CTPA were divided randomly into group A, with bolus tracing technique (n=26), and group B, with small dose injection contrast test (SDCT) (n=42). The CT values of the right main pulmonary artery (RMPA), right upper pulmonary vein (RUPV), right posterior basal PA, right lower PV (RLPV) and the aorta were calculated. The total contrast dosage and the hard beam artifact in the SVC were compared between the two groups.Student's t test, Chi-square test and Mann-Whitney U test were used. Results: The ratio of the time from starting injection to enhancement peak of caudal end of SVC and the time to enhancement peak of the main pulmonary trunk was 0.65 ±0.09 (about 2/3), the formula for contrast dosage calculation was derived as (DTs/3 + STs/2) FR ml/s. The CT values of RMPA and RLPA between the two groups [(301 ±117), (329 ± 122) and (283 ±95), (277 ±98) HU respectively] were not significantly different (t=1.060, P=0.292; t=2.056, P=0.044), but the differences of CT values in the paired PA and PV between the two groups (median were 22.5, 58.0 and 170.5, 166.5 HU respectively) were significant (U=292, P=0.001 and U=325, P=0.005), contrast artifact of the SVC (grade 1-3) in group B (n=34, 7, 1 respectively) was significantly less than in group A (n=11, 10, 5 respectively, χ 2 =10.714, P=0.002), the contrast dosage injected in group A was ( 87.6 ± 7.3) ml, and in group B was (40.0 ±5.4) ml (P<0.01). Conclusion: CTPA with SDCT technique is superior to that with conventional bolus tracing technique regarding contrast dosage and contrast artifact in the SVC. (authors)

  20. NMR-CT in muscular disorders

    International Nuclear Information System (INIS)

    Matsumura, Kiichiro; Nakano, Imaharu; Ikehira, Hiroo; Fukuda, Nobuo; Tateno, Yukio.

    1986-01-01

    Proton NMR-CT (magnetic field strength 0.1 Tesla, resonant frequency 4.5 MHz) was performed in 15 normal (NC) and 20 Duchenne muscular dystrophy (DMD) males. The age ranged from 3 to 47 years for the NC males, and 1 to 14 years for the DMD males. In the DMD group there were one subclinical stage, 4 stage 1, 6 stage 2, 4 stage 3, and 5 stage 5 or higher patients. T 1 (longitudinal relaxation) images were obtained for three slices at the buttock, midthigh, and calf levels. The T 1 values were measured for the medial portion of the gluteus maximus, the vastus lateralis of the quadriceps femoris, the adductors, the sartorius, the gracilis, and the gastrocnemius muscles. Bound water fraction (BWF) was calculated from Fullerton's equation based on the fast diffusion model. The following results were obtained: (1) In the NC group, muscle T 1 values declined gradually with maturation under the age of 10, and became constant beyond that. The average T 1 value was 280 ms for the age group between 3 and 6 years, 270 ms for 7 and 10 years, and 260 ms for those older than 10 years. (2) Muscle BWF increased with maturation in the NC group. (3) In the DMD group, T 1 values were initially higher than normal (300 ms), declined rapidly with the progress of the disease, and reached the same low level as the subcutaneous fat (190 ms). (4) This decrease of T 1 value in DMD was not uniform for all muscles, being most prominent in the gluteus maximus and least so in the sartorius and gracilis. (5) In the early stages of DMD, the BWF was lower than normal. (J.P.N.)