WorldWideScience

Sample records for unilateral ventilation-perfusion defect

  1. Regional ventilation/perfusion mismatch pattern in patient with Swyer James (MacLeod′s syndrome

    Directory of Open Access Journals (Sweden)

    Sait Sager

    2014-01-01

    Full Text Available Swyer James (McLeod′s syndrome (SJMS is an uncommon disease, which occurs as a result of childhood bronchiolitis obliterans. Patients may not be diagnosed until later in their life. A 46-year-old man underwent ventilation/perfusion scintigraphy for acute onset of dyspnea. The scan showed markedly diminished ventilation and perfusion unilaterally on the right middle and inferior lobes. However, mismatched ventilation-perfusion pattern was shown on the upper right lobe, which was consistent with pulmonary embolism. Unilaterally matched ventilation/perfusion defect can see in SJMS in lung scintigraphy; however, when pulmoner embolism may accompany, scintigraphy should be carefully examined.

  2. Reversible ventilation and perfusion abnormalities in unilateral obstructed lung

    International Nuclear Information System (INIS)

    Ward, H.E.; Jones, R.L.; King, E.G.; Sproule, B.J.; Fortune, R.L.

    1982-01-01

    An intraluminal carcinoid tumor obstructing the left mainstem bronchus produced hypoxemia through alteration in ventilation/perfusion matching. Studies of regional lung function using 133-xenon (/sup 133/Xe) and a multiprobe computerized instrumentation system documented a reduction of perfusion to 22 percent and ventilation to 6 percent of the total. There was negligible washout of intravenously injected /sup 133/Xe from the left lung consistent with air trapping. Four days after left mainstem bronchial sleeve resection, perfusion, ventilation and washout of injected xenon had significantly improved and by four months postresection, all measurements were virtually normal, although complete restoration of perfusion in relation to ventilation was delayed. Regional lung function studied with a multiprobe system in this patient provided a clinical model for the study of ventilation and perfusion inter-relationships in large airway obstruction and demonstrated that a prolonged time may be required for return of perfusion to normal

  3. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis

    Science.gov (United States)

    Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas

    2012-04-01

    To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between

  4. Ventilation perfusion radionuclide imaging in cryptogenic fibrosing alveolitis

    International Nuclear Information System (INIS)

    Bourke, S.J.; Hawkins, T.; Keavey, P.M.; Gascoigne, A.D.; Corris, P.A.

    1993-01-01

    There is increasing interest in ventilation perfusion (V/Q) imaging in cryptogenic fibrosing alveolitis because of the data these scans provide on the dynamic V/Q relationships in such patients undergoing single lung transplantation. We analysed the V/Q scans of 45 consecutive patients with advanced cryptogenic fibrosing alveolitis being considered for single lung transplantation. Scans were classified according to the presence, severity and degree of matching of defects in ventilation and perfusion images and the results were compared with the data obtained from lung function tests. Ventilation images showed defects in 13 (29%) and ''washout delay'' in 15 (33%) patients; 10 (22%) patients had asymmetric distribution of ventilation with one lung receiving >60% of total ventilation. Perfusion images showed normal perfusion in 8 (18%), mild defects in 18 (40%) and major defects in 19 (42%) patients. The distribution of perfusion between lungs was significantly asymmetric in 20 (45%) patients. V/Q images were matched in 15 (33%), mildly mismatched in 15 (33%) and severely mismatched in 15 (33%) patients, but the degree of V/Q mismatch did not show a relationship to KCO, PaO 2 or A-aO 2 gradient. The appearances were atypical of pulmonary embolism in eight patients. (Author)

  5. MR-based assessment of pulmonary ventilation-perfusion in animal models

    International Nuclear Information System (INIS)

    Yang Jian; Wan Mingxi; Guo Youmin

    2003-01-01

    Objective: To show the feasibility and value in the diagnosis of airway obstruction and pulmonary embolism with MR oxygen-enhanced ventilation combined with pulmonary perfusion imaging. Methods: Eight canines were implemented for peripheral pulmonary embolism by intravenous injection of gelfoam granules at pulmonary segmental arterial level, and five of them were formed airway obstruction models by inserting self-made balloon catheter at second-bronchia. The oxygen-enhanced MR ventilation imaging was introduced by subtracting the images of pre- and post- inhaled pure oxygen. The MR pulmonary perfusion imaging was achieved by the first-pass contrast agent method. Moreover, the manifestation of MR ventilation and perfusion imaging was observed and contradistinguished with that of general pathologic anatomy, ventilation-perfusion scintigraphy, and pulmonary angiography. Results: The manifestations of airway obstruction regions in MR ventilation and perfusion imaging were matched, but those of pulmonary embolism regions were dismatched. The defect range of airway obstruction in MR ventilation image was smaller than that in ventilation scintigraphy. The abnormal perfusion regions of pulmonary embolism were divided into defect regions and reduce regions based on the time courses of signal intensity changes. The sensitivity and specificity of diagnosis on pulmonary embolism by MR ventilation combined with perfusion technique were 75.0% and 98.1%. The diagnostic results were in good coherence with ventilation-perfusion scintigraphy and pulmonary angiography (K=0.743, 0.899). Conclusion: The MR oxygen-enhanced ventilation combined with pulmonary perfusion imaging can be used to diagnose the airway and vascular abnormity in lung. This technique resembles the ventilation-perfusion scintigraphy. It can provide quantitative functional information and better spatial and temporal resolution, and possesses the value of clinical application

  6. Pulmonary perfusion ''without ventilation''

    International Nuclear Information System (INIS)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-01-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  7. A comparative analysis of pulmonary ventilation-perfusion imaging with pulmonary angiography in the diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Wang Jincheng; Mi Hongzhi; Wang Qian; Zhang Weijun; Lu Biao; Yang Hao; Ding Jian; Lu Yao

    2001-01-01

    Objective: To assess the value of ventilation-perfusion imaging in the diagnosis of pulmonary embolism (PE). Methods: Thirty consecutive patients with clinically suspected pulmonary embolism were studied, male: female 15:15, mean age was (36.2 +- 13.9) years. The chest radiograms were obtained in all 30 patients. All patients underwent radionuclide ventilation-perfusion imaging and pulmonary angiography. Results: Of the 30 patients, 22 with lobe, multiple segment or multi-subsegment perfusion defects and normal or nearly normal ventilation images were reported as PE. 20 of them were confirmed to be with PE by pulmonary angiography, 2 patients were not confirmed. Eight of 30 patients with multiple perfusion defects, ventilative abnormalities were reported as non-PE and the diagnoses were confirmed by pulmonary angiography. The sensitivity, specificity and accuracy of diagnosis of PE by ventilation-perfusion imaging was 100%, 80.0% and 93.3% respectively. Conclusions: (1) Ventilation-perfusion imaging is one of the most valuable methods in the diagnosis of PE. (2) The results suggest that pulmonary embolism can be diagnosed non-invasively in most patients on the basis of clinical manifestation, chest radiograms and ventilation-perfusion imaging findings. (3) Pulmonary angiography is required while clinical manifestation and ventilation-perfusion imaging findings are discordant with each other

  8. Value of chest X-ray combined with perfusion scan versus ventilation/perfusion scan in acute pulmonary embolism

    NARCIS (Netherlands)

    de Groot, M. R.; Turkstra, F.; van Marwijk Kooy, M.; Oostdijk, A. H.; van Beek, E. J.; Büller, H. R.

    2000-01-01

    The main purpose of ventilation scanning, as adjunct to perfusion lung scintigraphy, in acute pulmonary embolism is to allow for the classification of segmental perfusion defects as mismatched, which is generally accepted as proof for the presence of pulmonary embolism. We examined whether this

  9. Methodology for ventilation/perfusion SPECT

    DEFF Research Database (Denmark)

    Bajc, Marika; Neilly, Brian; Miniati, Massimo

    2010-01-01

    radiolabeled liquid aerosols are not restricted to the presence of obstructive lung disease. Radiolabeled macroaggregated human albumin is the imaging agent of choice for perfusion scintigraphy. An optimal combination of nuclide activities and acquisition times for ventilation and perfusion, collimators......Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas over......, and imaging matrix yields an adequate V/Q SPECT study in approximately 20 minutes of imaging time. The recommended protocol based on the patient remaining in an unchanged position during the initial ventilation study and the perfusion study allows presentation of matching ventilation and perfusion slices...

  10. Reverse ventilation--perfusion mismatch

    International Nuclear Information System (INIS)

    Palmaz, J.C.; Barnett, C.A.; Reich, S.B.; Krumpe, P.E.; Farrer, P.A.

    1984-01-01

    Patients having lobar airway obstruction or consolidation usually have decreases of both ventilation and perfusion on lung scans. We report three patients in whom hypoxic vasoconstriction was apparently incomplete, resulting in a ''reversed'' ventilation-perfusion mismatch. Perfusion of the hypoxic lobe on the radionuclide scan was associated with metabolic alkalosis, pulmonary venous and pulmonary arterial hypertension in these patients

  11. Ventilation-perfused studies using SPECT

    International Nuclear Information System (INIS)

    Zwijnenburg, A.

    1989-01-01

    A method for the quantitative analysis of ventilation-perfusion SPECT studies is decribed and an effort is made to evaluate its usefullness. The technical details of the emthod are described. In the the transaxial reconstructions of the tomographic studies the contour of the lungs is detected and regional values of lung volume, ventilation, perfusion and ventilation-perfusion ratios are calculated. The method is operator independent. The lung volume calculations from the SPECT studies are validated by comparing them with lung volume measurements using the helium dilution technique. A good correlation (r=0.91) was found between the two volumes. SPECT volume was greater than the volume measured with helium dilution, which was attributed to non-gas-containing structures in the. lungs. The use of ventilation-perfusion ratio SPECT is described to evaluate the effect of ionizing radiation on the lungs in patients treated with mantle field irradiation for Hodgkin's disease. Perfusion changes appear as early as 2 months after the start of irradiation. Ventilation changes appear later and relatively minor. No changes are seen outside the radiation portals. The ventilation-perfusion inequality in pulmonary sarcoidosis is treated. It is suggested that the decrease D LCO in these patients may be partly due to an even distribution of ventilation perfusion ratios. An effort is made to establish the properties of a new tracer used for the assessment of the metabolic function of the pulmonary endothelium. The lung uptake of I-123 IMP mimics the distribution of a perfusion tracer and it is suggested that this tracer may be useful for the early detection of pulmonary vascular damage, even when blood flow is still intact. Some aspects of the use of Kr-81m as a ventilation tracer are discussed as well as the effect of noise on Kr-81m SPECT reconstructions. (author). 146 refs.; 39 figs.; 8 tabs

  12. Assessment of regional lung functional impairment with co-registered respiratory-gated ventilation/perfusion SPET-CT images: initial experiences

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Zaki, Mohammed; Yamashita, Tomio; Seto, Aska; Matsumoto, Tsuneo; Matsunaga, Naofumi

    2004-01-01

    In this study, respiratory-gated ventilation and perfusion single-photon emission tomography (SPET) were used to define regional functional impairment and to obtain reliable co-registration with computed tomography (CT) images in various lung diseases. Using a triple-headed SPET unit and a physiological synchroniser, gated perfusion SPET was performed in a total of 78 patients with different pulmonary diseases, including metastatic nodules (n=15); in 34 of these patients, it was performed in combination with gated technetium-99m Technegas SPET. Projection data were acquired using 60 stops over 120 for each detector. Gated end-inspiration and ungated images were reconstructed from 1/8 data centered at peak inspiration for each regular respiratory cycle and full respiratory cycle data, respectively. Gated images were registered with tidal inspiration CT images using automated three-dimensional (3D) registration software. Registration mismatch was assessed by measuring 3D distance of the centroid of the nine selected round perfusion-defective nodules. Gated SPET images were completed within 29 min, and increased the number of visible ventilation and perfusion defects by 9.7% and 17.2%, respectively, as compared with ungated images; furthermore, lesion-to-normal lung contrast was significantly higher on gated SPET images. In the nine round perfusion-defective nodules, gated images yielded a significantly better SPET-CT match compared with ungated images (4.9±3.1 mm vs 19.0±9.1 mm, P<0.001). The co-registered SPET-CT images allowed accurate perception of the location and extent of each ventilation/perfusion defect on the underlying CT anatomy, and characterised the pathophysiology of the various diseases. By reducing respiratory motion effects and enhancing perfusion/ventilation defect clarity, gated SPET can provide reliable co-registered images with CT images to accurately characterise regional functional impairment in various lung diseases. (orig.)

  13. Ventilation and ventilation/perfusion ratios

    International Nuclear Information System (INIS)

    Valind, S.O.

    1989-01-01

    The thesis is based on five different papers. The labelling of specific tracer compounds with positron emitting radionuclides enables a range of structural, physiological and biochemical parameters in the lung to be measured non-invasively, using positron emission tomography. This concept affords a unique opportunity for in vivo studies of different expressions of pulmonary pathophysiology at the regional level. The present thesis describes the application of positron emission tomography to the measurements of ventilation and ventilation/perfusion ratios using inert gas tracers, neon-19 and nitrogen-13 respectively. The validity of the methods applied was investigated with respect to the transport of inert gas tracers in the human lung. Both ventilation and the ventilation/perfusion ratio may be obtained with errors less than 10 % in the normal lung. In disease, however, errors may increase in those instances where the regional ventilation is very low or the intra-regional gas flow distribution is markedly nonuniform. A 2-3 fold increase in ventilation was demonstrated in normal nonsmoking subjects going from ventral to dorsal regions in the supine posture. These large regional differences could be well explained by the intrinsic elastic properties of lung tissue, considering the gravitational gradient in transpulmonary pressure. In asymptomatic smokers substantial regional ventilatroy abnormalities were found whilst the regional gas volume was similar in smokers and nonsmokers. The uncoupling between ventilation and gas volume probably reflects inflammatory changes in the airways. The regional differences in dV/dt/dQ/dt were relatively small and blood flow was largely matched to ventilation in the supine posture. However, small regions of lung with very low ventilation, unmatched by blood flow commonly exists in the most dependent parts of the lung in both smokers and nonsmokers. (29 illustrations, 7 tables, 113 references)

  14. Ventilation and perfusion display in a single image

    International Nuclear Information System (INIS)

    Lima, J.J.P. de; Botelho, M.F.R.; Pereira, A.M.S.; Rafael, J.A.S.; Pinto, A.J.; Marques, M.A.T.; Pereira, M.C.; Baganha, M.F.; Godinho, F.

    1991-01-01

    A new method of ventilation and perfusion display onto a single image is presented. From the data on regions of interest of the lungs, three-dimensional histograms are created, containing as parameters X and Y for the position of the pixels, Z for the perfusion and colour for local ventilation. The perfusion value is supplied by sets of curves having Z proportional to the local perfusion count rate. Ventilation modulates colour. Four perspective views of the histogram are simultaneously displayed to allow visualization of the entire organ. Information about the normal ranges for both ventilation and perfusion is also provided in the histograms. (orig.)

  15. Pulmonary ventilation and perfusion abnormalities and ventilation perfusion imbalance in children with pulmonary atresia or extreme tetralogy of Fallot

    Energy Technology Data Exchange (ETDEWEB)

    Dowdle, S.C.; Human, D.G.; Mann, M.D. (Univ. of Cape Town (South Africa))

    1990-08-01

    Xenon-133 lung ventilation and perfusion scans were done preoperatively after cardiac catheterization and cineangiocardiography in 19 children; 6 had pulmonary atresia with an intact ventricular septum and hypoplastic right ventricle, 4 pulmonary atresia with associated complex univentricular heart, and 9 extreme Tetralogy of Fallot. The four patients with discrepancies in the sizes of the left and right pulmonary arteries on angiography had marked asymmetry of pulmonary perfusion and ventilation-perfusion imbalance on scintigraphy. Similar degrees of asymmetry and imbalance were present in 6 of the 15 children with equal-size pulmonary vessels. Asymmetry of pulmonary perfusion and ventilation-perfusion imbalance were associated with a poor prognosis.

  16. Pulmonary ventilation and perfusion abnormalities and ventilation perfusion imbalance in children with pulmonary atresia or extreme tetralogy of Fallot

    International Nuclear Information System (INIS)

    Dowdle, S.C.; Human, D.G.; Mann, M.D.

    1990-01-01

    Xenon-133 lung ventilation and perfusion scans were done preoperatively after cardiac catheterization and cineangiocardiography in 19 children; 6 had pulmonary atresia with an intact ventricular septum and hypoplastic right ventricle, 4 pulmonary atresia with associated complex univentricular heart, and 9 extreme Tetralogy of Fallot. The four patients with discrepancies in the sizes of the left and right pulmonary arteries on angiography had marked asymmetry of pulmonary perfusion and ventilation-perfusion imbalance on scintigraphy. Similar degrees of asymmetry and imbalance were present in 6 of the 15 children with equal-size pulmonary vessels. Asymmetry of pulmonary perfusion and ventilation-perfusion imbalance were associated with a poor prognosis

  17. Imaging features of isolated unilateral pulmonary artery agenesis presenting in adulthood: a review of four cases

    International Nuclear Information System (INIS)

    Griffin, N.; Mansfield, L.; Redmond, K.C.; Dusmet, M.; Goldstraw, P.; Mittal, T.K.; Padley, S.

    2007-01-01

    Aim: To highlight the variation in clinical manifestations, imaging and management of four cases of unilateral pulmonary artery agenesis presenting in adulthood. Method: Four patients with unilateral pulmonary artery agenesis were referred to our institution between 1995 and 2005. They underwent a series of investigations, including chest radiography, echocardiography, ventilation perfusion scintigraphy, angiography, computed tomography (CT) and magnetic resonance imaging (MRI). Results: Two of the four patients had absence of the right main pulmonary artery, whilst the remaining two patients had absence of the left main pulmonary artery. One patient showed a restrictive defect on pulmonary function tests. Two patients who had ventilation perfusion scintigraphy showed absent perfusion and reduced ventilation on the affected side. Angiography (where performed), CT and MRI confirmed the anatomy and the presence of multiple collaterals. Bronchiectasis was demonstrated on CT in two patients, with one also demonstrating a mosaic attenuation pattern. One patient had an incidental lung tumour on the side of the agenesis, which was diagnosed as a chondroid hamartoma on histology. Three of the four patients eventually underwent resection of the affected lung. Conclusion: Isolated unilateral pulmonary artery agenesis has a non-specific presentation. Awareness of this condition can lead to earlier diagnosis, with cross-sectional imaging making an important contribution

  18. Imaging features of isolated unilateral pulmonary artery agenesis presenting in adulthood: a review of four cases

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, N. [Royal Brompton and Harefield NHS Trust, London (United Kingdom)]. E-mail: nyreegriffin@hotmail.com; Mansfield, L. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Redmond, K.C. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Dusmet, M. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Goldstraw, P. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Mittal, T.K. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Padley, S. [Royal Brompton and Harefield NHS Trust, London (United Kingdom)

    2007-03-15

    Aim: To highlight the variation in clinical manifestations, imaging and management of four cases of unilateral pulmonary artery agenesis presenting in adulthood. Method: Four patients with unilateral pulmonary artery agenesis were referred to our institution between 1995 and 2005. They underwent a series of investigations, including chest radiography, echocardiography, ventilation perfusion scintigraphy, angiography, computed tomography (CT) and magnetic resonance imaging (MRI). Results: Two of the four patients had absence of the right main pulmonary artery, whilst the remaining two patients had absence of the left main pulmonary artery. One patient showed a restrictive defect on pulmonary function tests. Two patients who had ventilation perfusion scintigraphy showed absent perfusion and reduced ventilation on the affected side. Angiography (where performed), CT and MRI confirmed the anatomy and the presence of multiple collaterals. Bronchiectasis was demonstrated on CT in two patients, with one also demonstrating a mosaic attenuation pattern. One patient had an incidental lung tumour on the side of the agenesis, which was diagnosed as a chondroid hamartoma on histology. Three of the four patients eventually underwent resection of the affected lung. Conclusion: Isolated unilateral pulmonary artery agenesis has a non-specific presentation. Awareness of this condition can lead to earlier diagnosis, with cross-sectional imaging making an important contribution.

  19. Ventilation-perfusion distribution in normal subjects.

    Science.gov (United States)

    Beck, Kenneth C; Johnson, Bruce D; Olson, Thomas P; Wilson, Theodore A

    2012-09-01

    Functional values of LogSD of the ventilation distribution (σ(V)) have been reported previously, but functional values of LogSD of the perfusion distribution (σ(q)) and the coefficient of correlation between ventilation and perfusion (ρ) have not been measured in humans. Here, we report values for σ(V), σ(q), and ρ obtained from wash-in data for three gases, helium and two soluble gases, acetylene and dimethyl ether. Normal subjects inspired gas containing the test gases, and the concentrations of the gases at end-expiration during the first 10 breaths were measured with the subjects at rest and at increasing levels of exercise. The regional distribution of ventilation and perfusion was described by a bivariate log-normal distribution with parameters σ(V), σ(q), and ρ, and these parameters were evaluated by matching the values of expired gas concentrations calculated for this distribution to the measured values. Values of cardiac output and LogSD ventilation/perfusion (Va/Q) were obtained. At rest, σ(q) is high (1.08 ± 0.12). With the onset of ventilation, σ(q) decreases to 0.85 ± 0.09 but remains higher than σ(V) (0.43 ± 0.09) at all exercise levels. Rho increases to 0.87 ± 0.07, and the value of LogSD Va/Q for light and moderate exercise is primarily the result of the difference between the magnitudes of σ(q) and σ(V). With known values for the parameters, the bivariate distribution describes the comprehensive distribution of ventilation and perfusion that underlies the distribution of the Va/Q ratio.

  20. Magnetic Resonance Imaging of Ventilation and Perfusion in the Lung

    Science.gov (United States)

    Prisk, Gordon Kim (Inventor); Hopkins, Susan Roberta (Inventor); Buxton, Richard Bruce (Inventor); Pereira De Sa, Rui Carlos (Inventor); Theilmann, Rebecca Jean (Inventor); Cronin, Matthew Vincent (Inventor)

    2017-01-01

    Methods, devices, and systems are disclosed for implementing a fully quantitative non-injectable contrast proton MRI technique to measure spatial ventilation-perfusion (VA/Q) matching and spatial distribution of ventilation and perfusion. In one aspect, a method using MRI to characterize ventilation and perfusion in a lung includes acquiring an MR image of the lung having MR data in a voxel and obtaining a breathing frequency parameter, determining a water density value, a specific ventilation value, and a perfusion value in at least one voxel of the MR image based on the MR data and using the water density value to determine an air content value, and determining a ventilation-perfusion ratio value that is the product of the specific ventilation value, the air content value, the inverse of the perfusion value, and the breathing frequency.

  1. Pulmonary perfusion ''without ventilation''

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-12-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  2. Methodology for ventilation/perfusion SPECT

    DEFF Research Database (Denmark)

    Bajc, Marika; Neilly, Brian; Miniati, Massimo

    2010-01-01

    Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas ov...

  3. Clinical studies on combined ventilation (sup(81m)Kr)/perfusion (sup(99m)Tc-MAA) scintigraphy

    International Nuclear Information System (INIS)

    Yamamoto, Keiichiro; Miyamae, Tatsuya

    1983-01-01

    One hundred fifty patients having pulmonary disease underwent pulmonary scintigraphy sequentially with sup(99m)Tc-MAA and sup(81m)Kr gases. Scintigrams of matched defect were obtained from 113 (75.3%) of the 150 patients, considered to be nonspecific universal pattern of a pulmonary disease. Scintigrams of mismatched defect (absent perfusion and homogeneous ventilation) were obtained from 20 patients (13.3%), including 6 with lung carcinoma, 3 with pulmonary embolism, 3 with connective tissue disease, 2 with aortitis syndrome and 6 with other diseases. Scintigrams of mismatch with impaired ventilation and normal perfusion were mainly seen in chronic obstructive lung diseases. Of the 10 patients with bronchial asthma, 5 had scintigrams of improved ventilation after intravenous injection of 250 mg aminophilline, but none of patients with emphysema. The combined scintigraphy has made significant contributions to diagnosis and management of patients with pulmonary disease where the chest X-ray is unhelpful. (author)

  4. Imaging of ventilation/perfusion ratio by gated regional spirometry

    International Nuclear Information System (INIS)

    Touya, J.J.; Jones, J.P.; Price, R.R.; Patton, J.A.; Erickson, J.J.; Rollo, F.D.

    1981-01-01

    Gated 133 Xe images of patients rebreathing into a closed system can provide images of the distribution of lung volumes, ventilation and specific ventilation. These have been shown to be accurate, precise, and do not require unusually sophisticated equipment or skills. A mathematical transformation is used to correct the images for lung movement, which does not alter the total number of counts in the image. Perfusion images are gated to remove motion blurring but not transformed. Ventilation/perfusion images showing the distribution of V/Q ratio are then generated from the individual ventilation and perfusion images. (author)

  5. Pulmonary ventilation and perfusion imaging with dual-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F. [Klinikum Grosshadern, Department of Clinical Radiology, Ludwig Maximilians University, Muenchen (Germany); Klinikum Grosshadern, Institut fuer Klinische Radiologie, LMU Muenchen, Muenchen (Germany); Hoegl, Sandra; Fisahn, Juergen; Irlbeck, Michael [Klinikum Grosshadern, Department of Anesthesiology, Ludwig Maximilians University, Muenchen (Germany); Nikolaou, Konstantin; Maxien, Daniel; Reiser, Maximilian F.; Becker, Christoph R.; Johnson, Thorsten R.C. [Klinikum Grosshadern, Department of Clinical Radiology, Ludwig Maximilians University, Muenchen (Germany)

    2010-12-15

    To evaluate the feasibility of dual-energy CT (DECT) ventilation imaging in combination with DE perfusion mapping for a comprehensive assessment of ventilation, perfusion, morphology and structure of the pulmonary parenchyma. Two dual-energy CT acquisitions for xenon-enhanced ventilation and iodine-enhanced perfusion mapping were performed in patients under artificial respiration. Parenchymal xenon and iodine distribution were mapped and correlated with structural or vascular abnormalities. In all datasets, image quality was sufficient for a comprehensive image reading of the pulmonary CTA images, lung window images and pulmonary functional parameter maps and led to expedient results in each patient. With dual-source CT systems, DECT of the lung with iodine or xenon administration is technically feasible and makes it possible to depict the regional iodine or xenon distribution representing the local perfusion and ventilation. (orig.)

  6. Radioaerosol ventilation imaging in ventilator-dependent patients. Technical considerations

    International Nuclear Information System (INIS)

    Vezina, W.; Chamberlain, M.; Vinitski, S.; King, M.; Nicholson, R.; Morgan, W.K.

    1985-01-01

    The differentiation of pulmonary embolism (PE) from regional ventilatory abnormalities accompanied by reduced perfusion requires contemporary perfusion and ventilation studies. Distinguishing these conditions in ventilator-dependent patients is aided by administering a Tc-99m aerosol to characterize regional ventilation, and by performing a conventional Tc-99m MAA perfusion study. The technique uses a simple in-house constructed apparatus. Simple photographic techniques suffice, but computer subtraction of perfusion from the combined perfusion-ventilation image renders interpretation easier if aerosol administration follows perfusion imaging. Multiple defects can be examined in a single study. Excluding normal or near-normal perfusion studies, PE was thought to be present in eight of 16 patients after perfusion imaging alone, but in only one of eight after added aerosol imaging. Angiography confirmed the diagnosis in that patient. Of the eight patients who had abnormal perfusion but were thought unlikely to have PE from the perfusion study alone, two had normal ventilation, and subsequently were shown to have PE by angiography. Because angiography was only performed on patients who were thought to have a high probability of PE on sequential perfusion-ventilation imaging, the true incidence of PE may have been higher. Aerosol ventilation imaging is a useful adjunct to perfusion imaging in patients on ventilators. It requires an efficient delivery system, particularly if aerosol administration follows perfusion imaging, as it does in this study

  7. Pulmonary ventilation/perfusion scan

    Science.gov (United States)

    ... to stop eating (fast), be on a special diet, or take any medicines before the test. A chest x-ray is usually done before or after a ventilation and perfusion scan. You wear a hospital gown or comfortable clothing that does not have ...

  8. Regional assessment of treatment in lung cancer using lung perfusion and ventilation images

    International Nuclear Information System (INIS)

    Horikoshi, Masaki; Teshima, Takeo; Yanagimachi, Tomohiro; Ogata, Yuuko; Nukiwa, Toshihiro

    2000-01-01

    In 30 patients with lung cancer undergoing non-surgical treatment, we performed perfusion lung imaging using 99m Tc-MAA and inhalation lung studies using Technegas before and after treatment and evaluated regional perfusion and ventilation status in the lung regions where bronchogenic carcinoma was located. Regional ventilation status was preserved rather than perfusion counterpart (V>P) in 18 patients (18/30=60.0%) before treatment, while the former was better than the latter in 27 patients (27/30=90.0%) after treatment, indicating that regional ventilation status improved more significantly than regional perfusion counterpart after treatment (P=0.005). We also classified the therapeutic effect for regional perfusion and ventilation status as improved, unchanged, or worsened, respectively; improvement in regional perfusion status was observed in 17 patients (56.7%) and that in regional ventilation status in 24 patients (80.0%). There was a statistically significant correlation between improved regional perfusion and ventilation status (P=0.0018) when therapeutic effect was recognized. The patients who showed improvement in regional perfusion status after treatment always showed improved regional ventilation status, but 7 patients showed either unchanged or worsened regional perfusion status after treatment, although regional ventilation status was improved. In conclusion the pulmonary vascular beds seem more vulnerable to bronchogenic carcinoma and improvement in regional perfusion status was revealed to be more difficult than that in regional ventilation status after treatment. (author)

  9. Counting the mismatches - lung ventilation/perfusion subtraction index

    International Nuclear Information System (INIS)

    Anderson, T.C.; Evans, S.G.; Larcos, G.; Farlow, D.C.

    1998-01-01

    Full text: There is potential for interobserver variability in interpretation of ventilation/perfusion (V/Q) scans. Objective quantification of V/Q mismatch could be useful. Thus, the aim of this study is to determine the validity of image subtraction in a group of 27 patients (11 men, 8 women; mean age 59.4 years [range 21-81 years])investigated by V/Q scans for suspected pulmonary emboli. A standard 6 view V/Q scan was obtained with two cobalt markers used on the anterior and posterior surfaces for image alignment. Ventilation images were normalised to the perfusion using an area of normal ventilation and perfusion. With the use of automated, and if required, manual alignment, perfusion images were subtracted from ventilation, with a median filter applied. A summed index of mismatch for each lung scan was calculated from the difference. This index was then retrospectively compared to the result reported by one of four experienced physicians. Two patients with chronic obstructive airways disease were excluded from analysis. We conclude that high probability V/Q scans can be differentiated from low probability studies using this index; further prospective investigation in a larger cohort is warranted

  10. Pulmonary ventilation and perfusion scintigraphy in patients with bronchial asthma

    International Nuclear Information System (INIS)

    Ono, Seiji; Hoshi, Hiroaki; Watanabe, Katsushi.

    1988-01-01

    Pulmonary ventilation and perfusion scan using Xe-133 gas and Tc-99m MAA were performed in 18 patients with bronchial asthma to evaluate the regional pulmonary function. The scintigraphic findings were compared with the results of the auscultation and the conventional pulmonary functioning examination (%FVC, %FEV 1.0 ). Ventilation image showed abnormality in 12 (70.6%) out of the asymptomatic 17 patients and perfusion image showed abnormality in 7 (41.2%) out of 17 patients. These 7 patients with abnormality on perfusion image all showed abnormality on ventilation image. The grade of abnormality in scintigraphic findings was compatible with the values of %FVC and %FEV 1.0 . In conclusion Xe-133 ventilation and Tc-99m MAA perfusion scan were useful procedures to estimate the pulmonary function of patients with bronchial asthma. (author)

  11. Comparison of 4-Dimensional Computed Tomography Ventilation With Nuclear Medicine Ventilation-Perfusion Imaging: A Clinical Validation Study

    International Nuclear Information System (INIS)

    Vinogradskiy, Yevgeniy; Koo, Phillip J.; Castillo, Richard; Castillo, Edward; Guerrero, Thomas; Gaspar, Laurie E.; Miften, Moyed; Kavanagh, Brian D.

    2014-01-01

    Purpose: Four-dimensional computed tomography (4DCT) ventilation imaging provides lung function information for lung cancer patients undergoing radiation therapy. Before 4DCT-ventilation can be implemented clinically it needs to be validated against an established imaging modality. The purpose of this work was to compare 4DCT-ventilation to nuclear medicine ventilation, using clinically relevant global metrics and radiologist observations. Methods and Materials: Fifteen lung cancer patients with 16 sets of 4DCT and nuclear medicine ventilation-perfusion (VQ) images were used for the study. The VQ-ventilation images were acquired in planar mode using Tc-99m-labeled diethylenetriamine-pentaacetic acid aerosol inhalation. 4DCT data, spatial registration, and a density-change-based model were used to compute a 4DCT-based ventilation map for each patient. The percent ventilation was calculated in each lung and each lung third for both the 4DCT and VQ-ventilation scans. A nuclear medicine radiologist assessed the VQ and 4DCT scans for the presence of ventilation defects. The VQ and 4DCT-based images were compared using regional percent ventilation and radiologist clinical observations. Results: Individual patient examples demonstrate good qualitative agreement between the 4DCT and VQ-ventilation scans. The correlation coefficients were 0.68 and 0.45, using the percent ventilation in each individual lung and lung third, respectively. Using radiologist-noted presence of ventilation defects and receiver operating characteristic analysis, the sensitivity, specificity, and accuracy of the 4DCT-ventilation were 90%, 64%, and 81%, respectively. Conclusions: The current work compared 4DCT with VQ-based ventilation using clinically relevant global metrics and radiologist observations. We found good agreement between the radiologist's assessment of the 4DCT and VQ-ventilation images as well as the percent ventilation in each lung. The agreement lessened when the data were

  12. Unusual ventilation perfusion scintigram in a case of immunologic pulmonary edema clinically simulating pulmonary embolism

    International Nuclear Information System (INIS)

    Campeau, R.J.; Faust, J.M.; Ahmad, S.

    1987-01-01

    A case of immunologic pulmonary edema secondary to hydrochlorothiazide allergy developed in a 55-year-old woman that clinically simulated pulmonary embolism. The patient had abnormal washin images with normal washout images on an Xe-133 ventilation study. On the perfusion study, large bilateral central and posterior perfusion defects were present that showed an unusual mirror image pattern on the lateral and posterior oblique views. Resolution of radiographic and scintigraphic abnormalities occurred over a 3-day period in conjunction with corticosteroid therapy

  13. Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning.

    Science.gov (United States)

    Kunst, P W; Vonk Noordegraaf, A; Hoekstra, O S; Postmus, P E; de Vries, P M

    1998-11-01

    Electrical impedance tomography (EIT) is a technique that makes it possible to measure ventilation and pulmonary perfusion in a volume that approximates to a 2D plane. The possibility of using EIT for measuring the left-right division of ventilation and perfusion was compared with that of radionuclide imaging. Following routine ventilation (81mKr) and perfusion scanning (99mTc-MAA), EIT measurements were performed at the third and the sixth intercostal level in 14 patients with lung cancer. A correlation (r = 0.98, p RC) was calculated for estimating the left-right division with EIT. The RC for the ventilation measurements was 94% and 96% for the perfusion measurements. The correlation analysis for reproducibility of the EIT measurements was 0.95 (p < 0.001) for the ventilation and 0.93 (p < 0.001) for the perfusion measurements. In conclusion, EIT can be regarded as a promising technique to estimate the left-right division of pulmonary perfusion and ventilation.

  14. Pulmonary ventilation/perfusion single photon emission tomography – Initial experience of a Nuclear Medicine Department

    Directory of Open Access Journals (Sweden)

    J. G. Santos

    2016-01-01

    Full Text Available Introduction: Lung ventilation/perfusion scintigraphy with planar images (V/QS-planar is very useful for the diagnosis and follow-up of pulmonary thromboembolism (PTE. Acquiring tomographic images (V/QS-SPECT is a recent development with potential to increase the technique's accuracy. The purpose of this work is to evaluate the added benefits of V/QS-SPECT studies as opposed to traditional planar imaging. Patients and methods: We prospectively revised 53 V/QS-planar and V/QS-SPECT exams, performed according to the European Association of Nuclear Medicine guidelines. We evaluated the exams independently, by consensus of two Nuclear Medicine physicians. For both methods, we gave each lung a score expressing the dimension and extension of perfusion defects with normal ventilation. For each lung, we compared the scores with the paired Wilcoxon test, estimating the 95% confidence interval (95CI for the respective difference. Results: We performed V/QS-SPECT exams without technical difficulties. The paired Wilcoxon test estimated the score difference to be −0.75 (95CI of −1.0 to −0.5; p-value = 9.6 × 10−7, expressing a statistically significant difference of about 1 subsegmental defect between both methods, with V/QS-SPECT detecting more defects. Discussion: The results demonstrate that V/QS-SPECT identifies a slightly larger number of perfusion defects than V/QS-planar, suggesting a higher sensitivity of this technique. However, more studies are necessary to evaluate the clinical meaning of this fact. Conclusion: V/QS-SPECT demonstrates a higher capability to identify perfusion defects. This method looks promising, allowing for a greater role of this exam in pulmonary thromboembolism diagnosis and follow-up. Keywords: Pulmonary thromboembolism, Lung, Scintigraphy, Single-photon emission-computed tomography (SPECT

  15. Ventilation-perfusion lung imaging in diaphragmatic paralysis

    International Nuclear Information System (INIS)

    Chopra, S.K.; Taplin, G.V.

    1977-01-01

    Clinical, radiological, physiological, and lung imaging findings from a patient with paralysis of the diaphragm are described. Dyspnea, hypoxemia and hypercapnia increased when the patient changed from the upright to the supine positions. Ventilation (V) and perfusion (P) images of the right lung appeared to be relatively normal and remained nearly the same in the upright and supine positions. In contrast, V/P images of the left lung were smaller than those of the right lung in the upright position and decreased further in the supine position. In addition, the size of the ventilation image was much smaller than that of the perfusion

  16. Idiopathic pulmonary fibrosis. A rare cause of scintigraphic ventilation-perfusion mismatch

    International Nuclear Information System (INIS)

    Pochis, W.T.; Krasnow, A.Z.; Collier, B.D.; Mewissen, M.W.; Almagro, U.A.; Hellman, R.S.; Isitman, A.T.

    1990-01-01

    A case of idiopathic pulmonary fibrosis with multiple areas of mismatch on ventilation-perfusion lung imaging in the absence of pulmonary embolism is presented. Idiopathic pulmonary fibrosis is one of the few nonembolic diseases producing a pulmonary ventilation-perfusion mismatch. In this condition, chest radiographs may not detect the full extent of disease, and xenon-133 ventilation imaging may be relatively insensitive to morbid changes in small airways. Thus, when examining patients with idiopathic pulmonary fibrosis, one should be aware that abnormal perfusion imaging patterns without matching ventilation abnormalities are not always due to embolism. In this setting, contrast pulmonary angiography is often needed for accurate differential diagnosis

  17. Idiopathic pulmonary fibrosis. A rare cause of scintigraphic ventilation-perfusion mismatch

    Energy Technology Data Exchange (ETDEWEB)

    Pochis, W.T.; Krasnow, A.Z.; Collier, B.D.; Mewissen, M.W.; Almagro, U.A.; Hellman, R.S.; Isitman, A.T. (Medical College of Wisconsin, Milwaukee (USA))

    1990-05-01

    A case of idiopathic pulmonary fibrosis with multiple areas of mismatch on ventilation-perfusion lung imaging in the absence of pulmonary embolism is presented. Idiopathic pulmonary fibrosis is one of the few nonembolic diseases producing a pulmonary ventilation-perfusion mismatch. In this condition, chest radiographs may not detect the full extent of disease, and xenon-133 ventilation imaging may be relatively insensitive to morbid changes in small airways. Thus, when examining patients with idiopathic pulmonary fibrosis, one should be aware that abnormal perfusion imaging patterns without matching ventilation abnormalities are not always due to embolism. In this setting, contrast pulmonary angiography is often needed for accurate differential diagnosis.

  18. Effect of endobronchial valve therapy on pulmonary perfusion and ventilation distribution.

    Directory of Open Access Journals (Sweden)

    Carmen Pizarro

    Full Text Available Endoscopic lung volume reduction (ELVR is an emerging therapy for emphysematous COPD. However, any resulting changes in lung perfusion and ventilation remain undetermined. Here, we report ELVR-mediated adaptations in lung perfusion and ventilation, as investigated by means of pulmonary scintigraphy.In this observational study, we enrolled 26 patients (64.9 ± 9.4 yrs, 57.7% male with COPD heterogeneous emphysema undergoing ELVR with endobronchial valves (Zephyr, Pulmonx, Inc.. Mean baseline FEV1 and RV were 32.9% and 253.8% predicted, respectively. Lung scintigraphy was conducted prior to ELVR and eight weeks thereafter. Analyses of perfusion and ventilation shifts were performed and complemented by correlation analyses between paired zones.After ELVR, target zone perfusion showed a mean relative reduction of 43.32% (p<0.001, which was associated with a significant decrease in target zone ventilation (p<0.001. Perfusion of the contralateral untreated zone and of the contralateral total lung exhibited significant increases post-ELVR (p = 0.002 and p = 0.005, respectively; both correlated significantly with the corresponding target zone perfusion adaptations. Likewise, changes in target zone ventilation correlated significantly with ventilatory changes in the contralateral untreated zone and the total contralateral lung (Pearson's r: -0.42, p = 0.04 and Pearson's r: -0.42, p = 0.03, respectively. These effects were observed in case of clinical responsiveness to ELVR, as assessed by changes in the six-minute walk test distance.ELVR induces a relevant decrease in perfusion and ventilation of the treated zone with compensatory perfusional and ventilatory redistribution to the contralateral lung, primarily to the non-concordant, contralateral zone.

  19. Assessment of smoking-induced impairment of pulmonary perfusion using three-dimensional SPECT images

    Energy Technology Data Exchange (ETDEWEB)

    Miyasaka, Takashi [Toho Univ., Tokyo (Japan). School of Medicine

    1997-09-01

    The effects of smoking on ventilation-perfusion lung scintigrams were investigated. The subjects comprised 40 healthy males (28 smokers and 12 nonsmokers) without a history of cardiopulmonary disease and with normal chest radiographs. After acquisition of planar images of ventilation lung scintigrams with 370 MBq of {sup 133}Xe gas, planar images and SPECT images of pulmonary perfusion flow were obtained using 185 MBq of {sup 99m}Tc-MAA. Planar imaging showed perfusion defects in only 5 smokers. In contrast, 16 subjects were found to have perfusion defects on SPECT images (p<0.05), indicating the usefulness of SPECT images in detecting minor vascular damage of the lung. Although perfusion defects were common in the smokers (p<0.05), their relationship to the BRINKMAN index was uncertain. The perfusion defects found in the smokers were nonsegmental and commonly involved the right upper lobe. Ventilation scans revealed only delayed washout of {sup 133}Xe in 4 smokers, suggesting that smoking-induced abnormal perfusion on SPECT appears earlier than impaired ventilation on scintigrams. (author)

  20. Lung perfusion and ventilation scintigraphy in pre- and postoperative diagnostics

    International Nuclear Information System (INIS)

    Sandrock, D.; Munz, D.L.

    1998-01-01

    Lung perfusion (Tc-99m labeled albumin particles) and ventilation (Xe-133 gas) are used prior to thoracic surgery in order to evaluate changes in perfusion and ventilation due to the underlying diseases. Furthermore, perfusion scintigraphy allows combined with spirometry the prediction of the postinterventional vital capacity and the forced expiratory volume in 1 s. The correlation coefficient for this procedure compared with values measured postoperatively are in the range of 0.8. The method allows the assessment of operability in terms of postinterventional function. (orig.) [de

  1. Assessment of regional lung ventilation by electrical impedance tomography in a patient with unilateral bronchial stenosis and a history of tuberculosis.

    Science.gov (United States)

    Marinho, Liégina Silveira; Sousa, Nathalia Parente de; Barros, Carlos Augusto Barbosa da Silveira; Matias, Marcelo Silveira; Monteiro, Luana Torres; Beraldo, Marcelo do Amaral; Costa, Eduardo Leite Vieira; Amato, Marcelo Britto Passos; Holanda, Marcelo Alcantara

    2013-01-01

    Bronchial stenosis can impair regional lung ventilation by causing abnormal, asymmetric airflow limitation. Electrical impedance tomography (EIT) is an imaging technique that allows the assessment of regional lung ventilation and therefore complements the functional assessment of the lungs. We report the case of a patient with left unilateral bronchial stenosis and a history of tuberculosis, in whom regional lung ventilation was assessed by EIT. The EIT results were compared with those obtained by ventilation/perfusion radionuclide imaging. The patient was using nasal continuous positive airway pressure (CPAP) for the treatment of obstructive sleep apnea syndrome. Therefore, we studied the effects of postural changes and of the use of nasal CPAP. The EIT revealed heterogeneous distribution of regional lung ventilation, the ventilation being higher in the right lung, and this distribution was influenced by postural changes and CPAP use. The EIT assessment of regional lung ventilation produced results similar to those obtained with the radionuclide imaging technique and had the advantage of providing a dynamic evaluation without radiation exposure.

  2. Assessment of regional lung ventilation by electrical impedance tomography in a patient with unilateral bronchial stenosis and a history of tuberculosis

    Directory of Open Access Journals (Sweden)

    Liégina Silveira Marinho

    2013-12-01

    Full Text Available Bronchial stenosis can impair regional lung ventilation by causing abnormal, asymmetric airflow limitation. Electrical impedance tomography (EIT is an imaging technique that allows the assessment of regional lung ventilation and therefore complements the functional assessment of the lungs. We report the case of a patient with left unilateral bronchial stenosis and a history of tuberculosis, in whom regional lung ventilation was assessed by EIT. The EIT results were compared with those obtained by ventilation/perfusion radionuclide imaging. The patient was using nasal continuous positive airway pressure (CPAP for the treatment of obstructive sleep apnea syndrome. Therefore, we studied the effects of postural changes and of the use of nasal CPAP. The EIT revealed heterogeneous distribution of regional lung ventilation, the ventilation being higher in the right lung, and this distribution was influenced by postural changes and CPAP use. The EIT assessment of regional lung ventilation produced results similar to those obtained with the radionuclide imaging technique and had the advantage of providing a dynamic evaluation without radiation exposure.

  3. Ventilation-perfusion scans in neonatal regional pulmonary emphysema complicating ventilatory assistance

    International Nuclear Information System (INIS)

    Leonidas, J.C.; Moylan, F.M.B.; Kahn, P.C.; Ramenofsky, M.L.

    1978-01-01

    Two cases of ventilator-related neonatal lobar overexpansion with similar radiographic appearance, but probably different pathogenesis, are presented. In one infant, persistent interstitial lobar emphysema was confirmed by markedly decreased perfusion shown on scintigraphy; this information was of great value in predicting the beneficial effect of lobectomy. In the other case, ventilation and perfusion scans indicated functional value of the emphysematous lobe and correctly suggested conservative management. Radioisotope lung scans may provide valuable information regarding lung function in regional pulmonary emphysema associated with assisted ventilation in neonatal respiratory distress syndrome, and thus determine patient management

  4. Ventilation-perfusion imaging and pulmonary angiography: changing pattern of use

    International Nuclear Information System (INIS)

    Teates, C.D.; Bezirdjian, D.R.; Bray, S.T.; Tegtmeyer, C.J.

    1981-01-01

    The hospital and departmental records of the University of Virginia Medical Center from 1976 to 1980 show an increasing frequency of ventilation studies relative to perfusion studies and a decrease in frequency of ventilation-perfusion diagnosis of pulmonary embolus. Pulmonary angiograms have increased from one per 68 nuclear studies to one per 14. A review of 70 patients with correlating angiography or autopsy shows that 89% of nuclear studies were accurate. We have revised our interpretation criteria and indications for pulmonary angiography

  5. Ventilation/perfusion scintigraphy in children with post-infectious bronchiolitis obliterans: a pilot study.

    Directory of Open Access Journals (Sweden)

    Bo-Qia Xie

    Full Text Available PURPOSE: Childhood post-infectious bronchiolitis obliterans (BO is an infrequent lung disease leading to narrowing and/or complete obliteration of small airways. Ventilation and perfusion (V/Q scan can provide both regional and global pulmonary information. However, only few retrospective researches investigating post-infectious BO involved V/Q scan, the clinical value of this method is unknown. This preliminary prospective study was aimed to evaluate the correlation of V/Q scan with disease severity, pulmonary function test results, and prognosis in children with post-infectious BO. METHODS: Twenty-five post-infectious BO children (18 boys and 7 girls; mean age, 41 months underwent V/Q scan and pulmonary function tests. Patients were followed after their inclusion. Ventilation index and perfusion index obtained from V/Q scan were used to measure pulmonary abnormalities. Spearman's rank correlation test of ventilation index and perfusion index on disease severity, lung function tests indices, and follow-up results were performed. RESULTS: The median follow-up period was 4.6 years (range, 2.2 to 5.0 years. Ventilation index and perfusion index were both correlated with disease severity (r = 0.72, p<0.01 and r = 0.73, p<0.01, but only ventilation index was related to pulmonary function tests results (all p<0.05. In addition, Spearman test yielded significant correlations between perfusion index and prognosis (r = 0.77, p<0.01, and ventilation index and prognosis (r = 0.63, p = 0.01. CONCLUSIONS: For children with post-infectious BO, the present study preliminarily indicated that the degree of ventilation and perfusion abnormalities evaluated by V/Q scan may be used to assess disease severity, and may be predictive of patient's outcome.

  6. Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning

    NARCIS (Netherlands)

    Kunst, P. W.; Vonk Noordegraaf, A.; Hoekstra, O. S.; Postmus, P. E.; de Vries, P. M.

    1998-01-01

    Electrical impedance tomography (EIT) is a technique that makes it possible to measure ventilation and pulmonary perfusion in a volume that approximates to a 2D plane. The possibility of using EIT for measuring the left-right division of ventilation and perfusion was compared with that of

  7. Topographic distribution of pulmonary ventilation and perfusion in the horse

    International Nuclear Information System (INIS)

    Amis, T.C.; Pascoe, J.R.; Hornof, W.

    1984-01-01

    The regional distribution of ventilation to perfusion ratios (VA/Q) in the lungs of 8 healthy standing Thoroughbred geldings (4.4 +/- 1.5 years, 465.7 +/- 46.6 kg) was studied, using steady-state inhalation and IV infusion of the radioactive gas krypton-81m. The VA/Q was uniformly distributed within a vertical lung strip centered over the 9th rib on the right side. Ventilation per unit of alveolar volume (V/VA) assessed from the clearance of inhaled radioactive gas in 5 horses increased from 0.49 +/- 0.13 (arbitrary units) in nondependent lung zones to 1.45 +/- 0.16 in dependent lung zones. Seemingly, a vertical gradient of pulmonary ventilation exists in the horse that is matched by a similar gradient of perfusion

  8. Topographic distribution of pulmonary ventilation and perfusion in the horse

    Energy Technology Data Exchange (ETDEWEB)

    Amis, T.C.; Pascoe, J.R.; Hornof, W.

    1984-08-01

    The regional distribution of ventilation to perfusion ratios (VA/Q) in the lungs of 8 healthy standing Thoroughbred geldings (4.4 +/- 1.5 years, 465.7 +/- 46.6 kg) was studied, using steady-state inhalation and IV infusion of the radioactive gas krypton-81m. The VA/Q was uniformly distributed within a vertical lung strip centered over the 9th rib on the right side. Ventilation per unit of alveolar volume (V/VA) assessed from the clearance of inhaled radioactive gas in 5 horses increased from 0.49 +/- 0.13 (arbitrary units) in nondependent lung zones to 1.45 +/- 0.16 in dependent lung zones. Seemingly, a vertical gradient of pulmonary ventilation exists in the horse that is matched by a similar gradient of perfusion.

  9. Clinical studies on combined ventilation (sup(81m)Kr)/perfusion (sup(99m)Tc-MAA) scintigraphy. With special reference to the 'mismatch' patterns and their significance

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Keiichiro; Miyamae, Tatsuya [Saitama Medical School (Japan)

    1983-01-01

    One hundred fifty patients having pulmonary disease underwent pulmonary scintigraphy sequentially with sup(99m)Tc-MAA and sup(81m)Kr gases. Scintigrams of matched defect were obtained from 113 (75.3%) of the 150 patients, considered to be nonspecific universal pattern of a pulmonary disease. Scintigrams of mismatched defect (absent perfusion and homogeneous ventilation) were obtained from 20 patients (13.3%), including 6 with lung carcinoma, 3 with pulmonary embolism, 3 with connective tissue disease, 2 with aortitis syndrome and 6 with other diseases. Scintigrams of mismatch with impaired ventilation and normal perfusion were mainly seen in chronic obstructive lung diseases. Of the 10 patients with bronchial asthma, 5 had scintigrams of improved ventilation after intravenous injection of 250 mg aminophilline, but none of patients with emphysema. The combined scintigraphy has made significant contributions to diagnosis and management of patients with pulmonary disease where the chest X-ray is unhelpful.

  10. The diagnostic value of ventilation-perfusion scintigraphy combined with plasma D-dimer assay in diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Wang Qian; Huang Lili; Qin Shuling; Yue Minggang; Wang Yu; Nie Yuxin; Liang Tiejun

    2005-01-01

    Objective: To investigate the clinical diagnostic value of ventilation-perfusion scintigraphy combined with plasma D-dimer assay in diagnosis of pulmonary embolism (PE). Methods: One hundred and four patients with clinically suspected PE underwent both pulmonary ventilation-perfusion scintigraphy and plasma D-dimer assay. According to the criteria of prospective investigation of the pulmonary embolism diagnosis (PIOPED), ventilation-perfusion scintigraphy was interpreted as normal, very low or low probability of PE, intermediate probability of PE and high probability of PE. High probability was considered as positive; normal and very low or low probability as negative and intermediate probability as non-diagnostic. Plasma D-dimer levels were measured using a quantitative immunoturbidimetric method, and a cut-off value of 500 mg/L was used in the diagnosis of PE. Clinical diagnostic value of ventilation-perfusion scintigraphy, D-dimer assay and combined use of ventilation-perfusion scintigraphy and D-dimer assay for diagnosing PE was evaluated, respectively, comparing with the final clinical diagnosis that was based on the clinical findings. Results: Among the 104 patients, 44 were diagnosed with PE and 60 were excluded. Ventilation-perfusion scintigraphy provided diagnostic interpretations for 86 (82.7%) patients, and non-diagnostic interpretations for 18 (17.3%) patients. For diagnosing PE, the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of ventilation-perfusion scintigraphy was 84.1%, 75.0%, 78.8%, 71.2% and 86.5%, respectively, and with D-dimer assay was 93.2%, 60.0%, 74.0%, 63.1% and 92.3%, respectively. If a plasma D-dimer level of < 500 mg/L was taken as a criterion to exclude PE for those intermediate probability of ventilation-perfusion scintigraphy, the diagnostic specificity and accuracy would be raised to 85.0% and 84.6%, respectively. Conclusions: When a non-diagnostic interpretation was occurred on

  11. Fusion imaging of computed tomographic pulmonary angiography and SPECT ventilation/perfusion scintigraphy: initial experience and potential benefit

    International Nuclear Information System (INIS)

    Harris, Benjamin; Bailey, Dale; Roach, Paul; Bailey, Elizabeth; King, Gregory

    2007-01-01

    The objective of this study was to examine the feasibility of fusing ventilation and perfusion data from single-photon emission computed tomography (SPECT) ventilation perfusion (V/Q) scintigraphy together with computed tomographic pulmonary angiography (CTPA) data. We sought to determine the accuracy of this fusion process. In addition, we correlated the findings of this technique with the final clinical diagnosis. Thirty consecutive patients (17 female, 13 male) who had undergone both CTPA and SPECT V/Q scintigraphy during their admission for investigation of potential pulmonary embolism were identified retrospectively. Image datasets from these two modalities were co-registered and fused using commercial software. Accuracy of the fusion process was determined subjectively by correlation between modalities of the anatomical boundaries and co-existent pleuro-parenchymal abnormalities. In all 30 cases, SPECT V/Q images were accurately fused with CTPA images. An automated registration algorithm was sufficient alone in 23 cases (77%). Additional linear z-axis scaling was applied in seven cases. There was accurate topographical co-localisation of vascular, parenchymal and pleural disease on the fused images. Nine patients who had positive CTPA performed as an initial investigation had co-localised perfusion defects on the subsequent fused CTPA/SPECT images. Three of the 11 V/Q scans initially reported as intermediate could be reinterpreted as low probability owing to co-localisation of defects with parenchymal or pleural pathology. Accurate fusion of SPECT V/Q scintigraphy to CTPA images is possible. This technique may be clinically useful in patients who have non-diagnostic initial investigations or in whom corroborative imaging is sought. (orig.)

  12. The incidence and functional consequences of RT-associated cardiac perfusion defects

    International Nuclear Information System (INIS)

    Marks, Lawrence B.; Yu Xiaoli; Prosnitz, Robert G.; Zhou Sumin; Hardenbergh, Patricia H.; Blazing, Michael; Hollis, Donna; Lind, Pehr; Tisch, Andrea; Wong, Terence Z.; Borges-Neto, Salvador

    2005-01-01

    Purpose: Radiation therapy (RT) for left-sided breast cancer has been associated with cardiac dysfunction. We herein assess the temporal nature and volume dependence of RT-induced left ventricular perfusion defects and whether these perfusion defects are related to changes in cardiac wall motion or alterations in ejection fraction. Methods: From 1998 to 2001, 114 patients were enrolled onto an IRB-approved prospective clinical study to assess changes in regional and global cardiac function after RT for left-sided breast cancer. Patients were imaged 30 to 60 minutes after injection of technetium 99m sestamibi or tetrofosmin. Post-RT perfusion scans were compared with the pre-RT studies to assess for RT-induced perfusion defects as well as functional changes in wall motion and ejection fraction. Two-tailed Fisher's exact test and the Cochran-Armitage test for linear trends were used for statistical analysis. Results: The incidence of new perfusion defects 6, 12, 18, and 24 months after RT was 27%, 29%, 38%, and 42%, respectively. New defects occurred in approximately 10% to 20% and 50% to 60% of patients with less than 5%, and greater than 5%, of their left ventricle included within the RT fields, respectively (p = 0.33 to 0.00008). The rates of wall motion abnormalities in patients with and without perfusion defects were 12% to 40% versus 0% to 9%, respectively; p values were 0.007 to 0.16, depending on the post-RT interval. Conclusions: Radiation therapy causes volume-dependent perfusion defects in approximately 40% of patients within 2 years of RT. These perfusion defects are associated with corresponding wall-motion abnormalities. Additional study is necessary to better define the long-term functional consequences of RT-induced perfusion defects

  13. Clinical investigation of large perfusion defect cases with 201Tl exercise myocardial scintigraphy

    International Nuclear Information System (INIS)

    Morota, Motoi; Kobayashi, Yasuhiko

    1999-01-01

    We investigated retrospectively the clinical significance of large perfusion defect on 201 Thallium myocardial scintigraphy from the records of 833 patients during the past 3 years from 1991 to 1994. The patients were divided into 3 groups according to the extent of perfusion defect; cases with normal perfusion (n=561), with small perfusion defect (n=211) and with large perfusion defect (n=61). We found that the proportions of cases with large perfusion defect was significantly larger than that of cases with small perfusion defect in myocardial disease (MD; hypertrophic cardiomyopathy, dilated cardiomyopathy, and post myocarditis combined) (P 201 Thallium myocardial scintigraphy and that complication of diabetes mellitus and clinical symptoms may be useful in differentiating IHD from MD. (author)

  14. Regional distribution of perfusion and ventilation in hamartoangiomyomatosis of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Tominaga, Shigeru; Ohsaka, Tomohisa; Nanbu, Masashi; Toyoda, Keiko; Mori, Yutaka; Kawakami, Kenji; Inatomi, Keiko; Kira, Shiro

    1989-01-01

    We investigated regional distribution of perfusion and ventilation in three cases of hamartoangiomyomatosis (HAM) by /sup 133/Xe gas and /sup 99m/Tc-MAA. In two cases, /sup 133/Xe washout were dominantly delayed in middle lung field and in the third case, it was delayed in upper lung field. This distribution was different from the result in the other chronic obstructive pulmonary disease (COPD). In most cases of COPD, /sup 133/Xe washout was prominently delayed in the lower lung field. Distribution of pulmonary perfusion in HAM were consistent with that of ventilation as in COPD.

  15. Correlation of 68Ga Ventilation-Perfusion PET/CT with Pulmonary Function Test Indices for Assessing Lung Function.

    Science.gov (United States)

    Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S

    2015-11-01

    Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  16. Ventilation/Perfusion Positron Emission Tomography—Based Assessment of Radiation Injury to Lung

    International Nuclear Information System (INIS)

    Siva, Shankar; Hardcastle, Nicholas; Kron, Tomas; Bressel, Mathias; Callahan, Jason; MacManus, Michael P.; Shaw, Mark; Plumridge, Nikki; Hicks, Rodney J.; Steinfort, Daniel; Ball, David L.; Hofman, Michael S.

    2015-01-01

    Purpose: To investigate 68 Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). Methods and Materials: In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). Results: A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r 2 =0.99, P<.01), with ventilation strongly negatively linear (r 2 =0.95, P<.01). Logistic models did not provide a better fit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Conclusions: Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET/CT imaging. These

  17. Ventilation/Perfusion Positron Emission Tomography—Based Assessment of Radiation Injury to Lung

    Energy Technology Data Exchange (ETDEWEB)

    Siva, Shankar, E-mail: shankar.siva@petermac.org [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Sir Peter MacCallum Department of Oncology, University of Melbourne, Parkville (Australia); Hardcastle, Nicholas [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong (Australia); Kron, Tomas [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Bressel, Mathias [Department of Biostatistics and Clinical Trials, Peter MacCallum Cancer Centre, East Melbourne (Australia); Callahan, Jason [Centre for Molecular Imaging, Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); MacManus, Michael P.; Shaw, Mark; Plumridge, Nikki [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Hicks, Rodney J. [Centre for Molecular Imaging, Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Medicine, University of Melbourne, Parkville (Australia); Steinfort, Daniel [Department of Medicine, University of Melbourne, Parkville (Australia); Department of Cancer Medicine, Peter MacCallum Cancer Centre, East Melbourne (Australia); Ball, David L. [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Hofman, Michael S. [Centre for Molecular Imaging, Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Medicine, University of Melbourne, Parkville (Australia)

    2015-10-01

    Purpose: To investigate {sup 68}Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). Methods and Materials: In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). Results: A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r{sup 2}=0.99, P<.01), with ventilation strongly negatively linear (r{sup 2}=0.95, P<.01). Logistic models did not provide a better fit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Conclusions: Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET

  18. Are there any determinants of interictal brain SPECT perfusion change in unilateral hippocampal sclerosis?

    International Nuclear Information System (INIS)

    Tepmongkol, S.; Locharernkul, C.; Lerdlum, S.

    2005-01-01

    In localizing ictal onset during pre-surgical evaluation, interictal brain SPECT has been used to determine baseline brain abnormalities in order to compare with ictal SPECT. However, in some patients with hippocampal sclerosis (HS), no baseline perfusion abnormality is seen. In this subgroup of patients, performing interictal SPECT may be considered unnecessary. This study is aimed at determining the factors that may influence the interictal SPECT perfusion change in unilateral HS. Forty-one unilateral HS patients (21 males, 20 females; age 30.3±8.0 years) who had interictal brain perfusion SPECT (more than 24 hours after the seizure) were enrolled. Multiple factors i.e. age, sex, age of epilepsy onset, duration of epilepsy, presence of aura, clinical lateralization, interictal EEG lateralization, and ictal EEG lateralization were used as independent variables to predict hypoperfusion of the temporal lobe ipsilateral to hippocampal sclerosis detected on MRI. Ipsilateral temporal hypoperfusion were observed in 18/41 (43.9%) patients. None of these factors showed significant correlation to the perfusion changes. It was also concluded that age, sex, age of epilepsy onset, duration of epilepsy, presence of aura, clinical lateralization, interictal EEG lateralization, and ictal EEG lateralization cannot be used to predict interictal SPECT perfusion changes at the hippocampal sclerosis region. (author)

  19. Unilateral empyema impacts the assessment of regional lung ventilation by electrical impedance tomography

    International Nuclear Information System (INIS)

    Bläser, D; Becher, T; Schädler, D; Elke, G; Weiler, N; Frerichs, I; Pulletz, S

    2014-01-01

    Several studies have shown the ability of electrical impedance tomography (EIT) to assess regional ventilation distribution in human lungs. Fluid accumulation in the pleural space as in empyema, typically occurring on one chest side, may influence the distribution of ventilation and the corresponding EIT findings. The aim of our study was to examine this effect on the assessment of regional ventilation by EIT. Six patients suffering from unilateral empyema and intubated with a double-lumen endotracheal tube were studied. EIT data were acquired during volume-controlled ventilation with bilateral (tidal volume (V T ): 800 ml) and unilateral ventilation (V T : 400 ml) of the right and left lungs. Mean tidal amplitudes of the EIT signal were calculated in all image pixels. The sums of these values, expressed as relative impedance change (rel. ΔZ), were then determined in whole images and functionally defined regions-of-interest (ROI). The sums of rel. ΔZ calculated during the two cases of one-lung ventilation either on the affected or unaffected side were significantly smaller than during bilateral ventilation. However, in contrast to previous findings in patients with no pleural pathology, very low values of rel. ΔZ were found when the lung on the affected side was ventilated. ROI-based analysis rendered higher values than the whole-image analysis in this case, nonetheless, the values were significantly smaller than when the unaffected side was ventilated in spite of identical V T . In conclusion, our results indicate that the presence of empyema may affect the quantitative evaluation of regional lung ventilation by EIT. (paper)

  20. Measurement of ventilation- and perfusion-mediated cooling during laser ablation in ex vivo human lung tumors

    Energy Technology Data Exchange (ETDEWEB)

    Vietze, Andrea, E-mail: anvie@gmx.de [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany); Koch, Franziska, E-mail: franzi_koch@hotmail.com [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany); Laskowski, Ulrich, E-mail: ulrich.laskowski@klinikum-luedenscheid.de [Department of Vascular and Thoracic Surgery, Klinikum Luedenscheid, Paulmannshoeher Strasse 14, 58515 Luedenscheid (Germany); Linder, Albert, E-mail: albert.linder@klinikum-bremen-ost.de [Department of Thoracic Surgery, Klinikum Bremen-Ost, Zuericher Strasse 40, 28325 Bremen (Germany); Hosten, Norbert, E-mail: hosten@uni-greifswald.de [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany)

    2011-11-15

    Purpose: Perfusion-mediated tissue cooling has often been described in the literature for thermal ablation therapies of liver tumors. The objective of this study was to investigate the cooling effects of both perfusion and ventilation during laser ablation of lung malignancies. Materials and methods: An ex vivo lung model was used to maintain near physiological conditions for the specimens. Fourteen human lung lobes containing only primary lung tumors (non-small cell lung cancer) were used. Laser ablation was carried out using a Nd:YAG laser with a wavelength of 1064 nm and laser fibers with 30 mm diffusing tips. Continuous invasive temperature measurement in 10 mm distance from the laser fiber was performed. Laser power was increased at 2 W increments starting at 10 W up to a maximum power of 12-20 W until a temperature plateau around 60 deg. C was reached at one sensor. Ventilation and perfusion were discontinued for 6 min each to assess their effects on temperature development. Results: The experiments lead to 25 usable temperature profiles. A significant temperature increase was observed for both discontinued ventilation and perfusion. In 6 min without perfusion, the temperature rose about 5.5 deg. C (mean value, P < 0.05); without ventilation it increased about 7.0 deg. C (mean value, P < 0.05). Conclusion: Ventilation- and perfusion-mediated tissue cooling are significant influencing factors on temperature development during thermal ablation. They should be taken into account during the planning and preparation of minimally invasive lung tumor treatment in order to achieve complete ablation.

  1. Applications and interpretation of krypton 81m ventilation/technetium 99m macroaggregate perfusion lung scanning in childhood

    Science.gov (United States)

    Davies, Hugh Trevor Frimston

    Radionuclide ventilation perfusion lung scans now play an important part in the investigation of paediatric lung disease, providing a safe, noninvasive assessment of regional lung function in children with suspected pulmonary disease. In paediatric practice the most suitable radionuclides are Krypton 81m (Kr81m) and Technetium 99m (Tc99m), which are jointly used in the Kr81m ventilation/Tc99m macroaggregate perfusion lung scan (V/Q lung scan). The Kr81m ventilation scan involves a low radiation dose, requires little or no subject cooperation and because of the very short half life of Kr81m (13 seconds) the steady state image acquired during continuous inhalation of the radionuclide is considered to reflect regional distribution of ventilation. It is now the most important noninvasive method available for the investigation of the regional abnormalities of ventilation characteristic of many congenital and acquired paediatric respiratory diseases, such as diaphragmatic hernia, pulmonary sequestration, bronchopulmonary dysplasia, foreign body inhalation and bronchiectasis. It improves diagnostic accuracy, aids clinical decision making and is used to monitor the progress of disease and response to therapy. Theoretical analysis of the steady state Kr81m ventilation image suggests that it may only reflect regional ventilation when specific ventilation (ventilation per unit volume of lung) is within or below the normal adult range (1-3 L/L/min). At higher values such as those seen in neonates and infants (8-15 L/L/min) Kr81m activity may reflect regional lung volume rather than ventilation, a conclusion supported by the studies of Ciofetta et al. There is some controversy on this issue as animal studies have demonstrated that the Kr81m image reflects ventilation over a much wider range of specific ventilation (up to 13 L/L/min). A clinical study of sick infants and very young children is in agreement with this animal work and suggests that the steady state Kr81m image

  2. Clinical significance of ventilation/perfusion scans in collagen disease patients

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kenzo; Kobayashi, Takeshi [Tokyo Metropolitan Hiro-o Hospital (Japan); Kamata, Noriko; Inokuma, Shigeko; Terada, Hitoshi; Yokoyama, Yoshiaki; Abe, Katsumi; Mochizuki, Takao

    2000-12-01

    The purpose of this study was to detect disturbances in pulmonary circulation in collagen disease patients by means of a non-invasive technique. Ventilation/perfusion scans with {sup 133}Xe gas and {sup 99m}Tc-macroaggregated albumin (MAA) were performed in 109 patients with various collagen diseases. Functional images of V, Vol, Q and V/Q ratio were obtained at total lung capacity. Wash-out time was calculated from the wash-out curve. Whole body scans were performed in 65 patients to evaluate intra-pulmonary shunts. Increased V/Q areas were observed in 74 patients (67.9%), suggesting some impairment of pulmonary perfusion. Decreased perfusion, probably due to vasculitis or intravascular microcoagulation, was observed often, even in patients without pulmonary fibrosis. Shunt ratios over 10% were observed in 8 of the 65 patients (12.3%), indicating formation of PA-PV shunts secondary to peripheral vascular impairment. Wash-out time was prolonged in 37 patients (33.9%), shortened in 18 (16.5%), and within the normal range in 54 (49.6%). The prolonged and normal wash-out times in the patients with pulmonary fibrosis may represent obstructive changes in the small airways superimposed on the fibrosis. Ventilation/perfusion scans are a very useful tool for evaluating collagen lung diseases, and they might contribute to treatment decisions for the patients. (author)

  3. sup(99m)Tc particle perfusion/sup(99m)Tc aerosol ventilation imaging using a subtraction technique in suspected pulmonary embolism

    International Nuclear Information System (INIS)

    Poeyhoenen, L.; Turjanmaa, V.; Virjo, A.

    1985-01-01

    It is generally acknowledged that ventilation-perfusion mismatch is diagnostic of pulmonary embolism. Lung ventilation imaging with radioactive gases is a good method for the detection of pulmonary embolism, but it is not in widespread use because of the limited availability of sup(81m)Kr gas and the poor physical properties of 133 Xe. Aerosols have been proposed, instead of gases for use in lung ventilation imaging. As perfusion and ventilation distributions may change very rapidly, the two imaging procedures should be done in rapid succession. The cheapest way to perform the combined perfusion-ventilation (Q/V) imaging is to use sup(99m)Tc-labelled macroaggregates and aerosols. In our method the perfusion imaging was done first, immediately followed by the ventilation imaging with sup(99m)Tc-labelled aerosols. A computer program was used to subtract the contribution of the perfusion from the combined Q/V image so that the pure ventilation image alone was obtained. The method was tested in 41 patients with suspected pulmonary embolism. (orig.)

  4. Role of combined perfusion/ventilation scanning in diagnosis of pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Moustafa, H; Elhaddad, SH; Wageeh, SH; Samy, A; Abdo, S [Nuclear medicine and radiology department, faculty of medicine and Cairo university, Cairo, (Egypt)

    1995-10-01

    This study was conducted on 200 patients with suspected pulmonary embolism. Their age ranged 9-74 years with a mean age of 41.9+14.6 years.The commonest symptoms were dyspnea; chest pain and haemoptysis in 67.5%,49.5% and 14.5% respectively, whereas the main signs were tachycardia in 64.5% followed by rales and oedema of lower limbs in 28.5% and 14% respectively. Cardiac diseases were presenting the main risk factors in 47% followed by DVT, surgery, COLD in 24%,10% and 9.5% respectively. perfusion lung scan was normal in 27.5%, whereas low, intermediate and high probability scans were seen in 7%,23.5% and 42% respectively. The addition of ventilation scan, change probability of perfusion defects into 18.5%,19% and 31.5% in low, intermediate and high probability scans respectively. In addition 3.5% of patient diagnosed as non- embolic disease. There was significant correlation with increase number of symptoms and signs in relation to scan probability in both whole group and high probability group. Also, the incidence of pulmonary embolism appear to be additive with increase number of risk factors in the group of high probability scans. 3 figs., 3 tabs.

  5. Role of combined perfusion/ventilation scanning in diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Moustafa, H.; Elhaddad, SH.; Wageeh, SH.; Samy, A.; Abdo, S.

    1995-01-01

    This study was conducted on 200 patients with suspected pulmonary embolism. Their age ranged 9-74 years with a mean age of 41.9+14.6 years.The commonest symptoms were dyspnea; chest pain and haemoptysis in 67.5%,49.5% and 14.5% respectively, whereas the main signs were tachycardia in 64.5% followed by rales and oedema of lower limbs in 28.5% and 14% respectively. Cardiac diseases were presenting the main risk factors in 47% followed by DVT, surgery, COLD in 24%,10% and 9.5% respectively. perfusion lung scan was normal in 27.5%, whereas low, intermediate and high probability scans were seen in 7%,23.5% and 42% respectively. The addition of ventilation scan, change probability of perfusion defects into 18.5%,19% and 31.5% in low, intermediate and high probability scans respectively. In addition 3.5% of patient diagnosed as non- embolic disease. There was significant correlation with increase number of symptoms and signs in relation to scan probability in both whole group and high probability group. Also, the incidence of pulmonary embolism appear to be additive with increase number of risk factors in the group of high probability scans. 3 figs., 3 tabs

  6. Compression of the Right Pulmonary Artery by a Massive Defects on Pulmonary Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Makis, William [Brandon Regional Health Centre, Brandon (Canada); Derbekyan, Vilma [McGill Univ. Health Centre, Montreal (Canada)

    2012-03-15

    A 67 year old woman, who presented with a 2 month history of dyspnea, had a vectilation and perfusion lung scan that showed absent perfusion of the entire right lung scan that showed absent perfusion of the entire right lung with normal ventilation, as well as a rounded matched defect in the left lower lung adjacent to mialine, suspicious for an aortic aneurysm or dissection. CT pulmonary angiography revealed a massive descending aortic aneurysm compressing the right pulmonary artery as well as the left lung parenchyma, accounting for the bilateral perfusion scan defects. We present the Xe 133 ventilation, Tc 99m MAA perfusion and CT pulmonary angiography imaging findings of this rare case.

  7. Ventilation-perfusion-lungscintigraphy using PET and {sup 68}Ga-labeled radiopharmaceuticals; Ventilations-Perfusions-Lungenszintigraphie mit der PET und {sup 68}Ga-markierten Radiopharmaka

    Energy Technology Data Exchange (ETDEWEB)

    Kotzerke, J. [Technische Univ. Dresden (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Technische Univ. Dresden (Germany). OncoRay - Zentrum fuer Innovationskompetenz Strahlenforschung in der Onkologie; Forschungszentrum Dresden-Rossendorf e.V. (FZR) (Germany). PET-Zentrum; Andreeff, M.; Wunderlich, G.; Zoephel, K. [Technische Univ. Dresden (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Wiggermann, P. [Technische Univ. Dresden (Germany). Inst. und Poliklinik fuer Diagnostische Radiologie

    2010-07-01

    Aim: Imaging of lung perfusion with positron emission tomography (PET) is already possible with {sup 68}Ga labeled denaturized albumin. The purpose of our study was to produce and test a {sup 68}Ga labeled aerosol (Galligas {sup registered}) for ventilation and {sup 68}Ga labeled albumin particles (microspheres) for perfusion imaging with PET. Patients, methods: Galligas was produced by simmering and burning generator eluted {sup 68}Ga solution (100 MBq/0.1ml) in an ordinary technegas generator. Fifteen patients with suspicion on pulmonary embolism underwent PET/CT (Biograph 16) after inhalation of Galligas and application of {sup 68}Ga labeled microspheres. A low dose CT was acquired for attenuation correction (AC). Images were reconstructed with and without AC. The inhaled activity was calculated compared to the activity injected. Results: Inhaled radioaerosol Galligas demonstrated typical distribution as known from {sup 99m}Tc-labeled technegas with homogeneous distribution in lung without hilar deposits. Attenuation corrected images resulted in artefacts in the lung base. Therefore, non-corrected images were used for making the results. Three out of fifteen patients showed a deficient perfusion whereas ventilation was normal corresponding to pulmonary embolism. Conclusion: Lung scintigraphy with PET is feasible. Galligas is simple to produce (analogously to technegas). {sup 68}Ga labeled microspheres are available. The method is applicable to daily routine and rendered clinically relevant informations. (orig.)

  8. Pulmonary embolism: Prospective comparison of spiral CT with ventilation - perfusion scintigraphy

    International Nuclear Information System (INIS)

    Mayo Jhon R; Remi Jardin, Martine; Muller Mestor I

    1999-01-01

    The pulmonary thromboembolism (PTE) it is an entity common with great morbidity and mortality that it requires a diagnosis soon and specify. Commonly the ventilation gammagraphy - perfusion has been the used exam of first more frequent line when one suspects the PTE but unfortunately a great quantity of reports is called of intermediate probability, for what requires complementary studies, to confirm or to discard the diagnosis. A prospective study was made with 142 patients that had suspicion of TEP in the hospital of Vancouver (Canada) and in the hospital of Calmette (France), being carried out in all gammagraphy of ventilation-perfusion and helical CT, being only taken to lung angiography to those that not had high clinical suspicion of TEP with gammagraphy or helical CT very suggestive or tuneless, undergoing the results valuation for different observers

  9. Dynamic CT of portal hypertensive gastropathy: significance of transient gastric perfusion defect sign

    International Nuclear Information System (INIS)

    Kim, T.U.; Kim, S.; Woo, S.K.; Lee, J.W.; Lee, T.H.; Jeong, Y.J.; Heo, J.

    2008-01-01

    Aim: To evaluate the 'transient gastric perfusion defect' sign as a way of diagnosing portal hypertensive gastropathy (PHG) on multidetector computed tomography (CT). Materials and methods: Ninety-two consecutive patients with cirrhosis underwent three-phase CT and endoscopy. Endoscopy was performed within 3 days of the CT examination. As controls, 92 patients without clinical evidence of chronic liver diseases who underwent CT and endoscopy were enrolled; the findings at endoscopy were used as a reference standard for patients with PHG. Two radiologists who were unaware of the results of the endoscopy retrospectively interpreted the CT images. PHG was diagnosed on dynamic CT if the transient gastric perfusion defect sign was present. The transient gastric perfusion defect was defined as the presence of transient, segmental or subsegmental hypo-attenuating mucosa in the fundus or body of the stomach on hepatic arterial imaging that returned to normal attenuation on portal venous or equilibrium-phase imaging. The frequency of the transient gastric perfusion defect sign was compared between these two groups using Fisher's exact test. The frequency, sensitivity, specificity, positive predictive values, and negative predictive values of the transient gastric perfusion defect sign were also compared between patients with PHG and without PHG in the cirrhosis group. Results: Nine patients of 92 patients with cirrhosis were excluded because of previous procedure or motion artifact; the remaining 83 patients with cirrhosis were evaluated. In the cirrhosis group, 40 (48.1%) of 83 patients showed the transient gastric perfusion defect sign. In the control group, none of the 92 patients showed the transient gastric perfusion defect sign. In the cirrhotic group, the frequency of the transient gastric perfusion defect sign was significantly higher in the patients with PHG (75%, 36/48) than in patients without PHG (11.4%, 4/35). The sensitivity, specificity, positive predictive

  10. Abolished ventilation and perfusion of lung caused by blood clot in the left main bronchus

    DEFF Research Database (Denmark)

    Afzelius, P; Bergmann, A; Henriksen, J H

    2015-01-01

    /Q) scintigraphy with single-photon emission CT (SPECT)/CT. V/Q SPECT/CT demonstrated abolished ventilation due to obstruction of the left main bronchus and markedly reduced perfusion of the entire left lung, a condition that was completely reversed after removal of a blood clot. We present the first pictorially......It is generally assumed that the lungs possess arterial autoregulation associated with bronchial obstruction. A patient with pneumonia and congestive heart failure unexpectedly developed frequent haemoptysis. High-resolution CT and diagnostic CT were performed as well as ventilation/perfusion (V...

  11. Validation of co-registration of clinical lung ventilation and perfusion SPECT

    International Nuclear Information System (INIS)

    Marsh, S.H.; O'Keeffe, D.S.; Barnden, L.R.

    2010-01-01

    Full text: This talk will present results from a recent validation study of coregistration of computed tomography ventilation and perfusion (SPECT V/Q) images. The coregistration algorithm was incorporated in Qonsub, a program to coregister, normalise and subtract the SPECT (V/Q) images. Ventilation and perfusion image data were acquired from 23 patients undergoing a routine clinical SPECT V/Q study. The only change to normal patient management was the placement of three Tc 9 9 m filled fiducial markers adhered to the skin on the patient's torso. To quantify coregistration accuracy, image data were modified (within software) to remove the markers and Qonsub determined a parameter set of six values fully describing the six degree rigid transformation. The accuracy with which the six parameters coregister the images was then quantified by applying the same transformation parameters to the ventilation markers and determining how well they locate to the perfusion marker positions. Results show that for 65% of patients surveyed co-registration accuracy was to within I pixel, 30% were co-registered with an accuracy between 1 and 2 pixels and 5% were co-registered with an accuracy of between 2 and 3 pixels. Because patient placement between scans resulted in a misregistration of at most five pixels, a more rigorous test of the algorithm was required. Ethics approval had not been sought to intentionally misregister patient images, so the algorithm had to be further tested by synthetically misregistering the images. For these images Qonsub generally co-registered with the same accuracy as the original image. (author)

  12. Prediction of postoperative pulmonary function following thoracic operations. Value of ventilation-perfusion scanning

    International Nuclear Information System (INIS)

    Bria, W.F.; Kanarek, D.J.; Kazemi, H.

    1983-01-01

    Surgical resection of lung cancer is frequently required in patients with severely impaired lung function resulting from chronic obstructive pulmonary disease. Twenty patients with obstructive lung disease and cancer (mean preoperative forced expiratory volume in 1 second [FEV1] . 1.73 L) were studied preoperatively and postoperatively by spirometry and radionuclide perfusion, single-breath ventilation, and washout techniques to test the ability of these methods to predict preoperatively the partial loss of lung function by the resection. Postoperative FEV1 and forced vital capacity (FVC) were accurately predicted by the formula: postoperative FEV1 (or FVC) . preoperative FEV1 X percent function of regions of lung not to be resected (r . 0.88 and 0.95, respectively). Ventilation and perfusion scans are equally effective in prediction. Washout data add to the sophistication of the method by permitting the qualitative evaluation of ventilation during tidal breathing. Criteria for patients requiring the study are suggested

  13. Effect of Electrode Belt and Body Positions on Regional Pulmonary Ventilation- and Perfusion-Related Impedance Changes Measured by Electric Impedance Tomography.

    Directory of Open Access Journals (Sweden)

    Elin Ericsson

    Full Text Available Ventilator-induced or ventilator-associated lung injury (VILI/VALI is common and there is an increasing demand for a tool that can optimize ventilator settings. Electrical impedance tomography (EIT can detect changes in impedance caused by pulmonary ventilation and perfusion, but the effect of changes in the position of the body and in the placing of the electrode belt on the impedance signal have not to our knowledge been thoroughly evaluated. We therefore studied ventilation-related and perfusion-related changes in impedance during spontaneous breathing in 10 healthy subjects in five different body positions and with the electrode belt placed at three different thoracic positions using a 32-electrode EIT system. We found differences between regions of interest that could be attributed to changes in the position of the body, and differences in impedance amplitudes when the position of the electrode belt was changed. Ventilation-related changes in impedance could therefore be related to changes in the position of both the body and the electrode belt. Perfusion-related changes in impedance were probably related to the interference of major vessels. While these findings give us some insight into the sources of variation in impedance signals as a result of changes in the positions of both the body and the electrode belt, further studies on the origin of the perfusion-related impedance signal are needed to improve EIT further as a tool for the monitoring of pulmonary ventilation and perfusion.

  14. Comparative diagnostic value of pulmonary perfusion and ventilation scintigraphy and angiopneumography in pulmonary embolism

    International Nuclear Information System (INIS)

    Peltier, P.; Cesbron, J.P.; Dupas, B.; Crochet, D.; Delhumeau, J.

    1984-01-01

    Fourty-six patients suspected clinically of having a pulmonary embolism (PE) were investigated by angiopneumography (AGP) and perfusion (99m-Tc aggregates) and ventilation (99m-Tc colloid) scintigraohy (SPV Tc). Findings were assessed under blind conditions. A positive diagnosis of pulmonary embolism was made in 19 patients. The SPV Tc was considered as positive if perfusional deficiencies were greater than ventilatory defects, and this was evaluated as such in 23 cases (19 true and 4 false positives). False negatives were not observed. The 4 false positive results corresponded to scintigraphic anomalies suggestive of pulmonary emboli subsegmental in size; true positives were either subsegmental (8), segmental (6) or lobar (5). Sensitivity of the SPV Tc was therefore 100 %; its specificity, all results considered was 76 %, but was 100 % if only images of lobar or segmental lesions are considered [fr

  15. [MRI methods for pulmonary ventilation and perfusion imaging].

    Science.gov (United States)

    Sommer, G; Bauman, G

    2016-02-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O2-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies.

  16. MRI methods for pulmonary ventilation and perfusion imaging

    International Nuclear Information System (INIS)

    Sommer, G.; Bauman, G.

    2016-01-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O 2 -enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [de

  17. Radionuclide ventilation-perfusion studies in pediatric respiratory diseases: 157 measurements of the distribution of ventilation and perfusion in 130 children

    International Nuclear Information System (INIS)

    Guillet, J.; Basse-Cathalinat, B.; Christophe, E.; Saudubray, F.

    1983-01-01

    Radionuclide investigations provide regional quantitative and kinetic data with a very low exposure. Results are dissonant with roentgenographic findings in 52% of cases and enhance diagnostic and prognostic accuracy. Although it provides poor quality images. The use of 133 Xe is preferable for ventilation studies to ensure correct evaluation of washout and trapping. According to the patient's age and position, 50% washout times vary from 5.6 to 8.7 seconds in the upper segments and from 5.6 to 8.5 seconds in the lower segments. Distribution of blood flow can be studied after intravenous injection of either sup(99m)Tc labelled microspheres of human albumin or 133 Xe saline solution. The former provides better quality images with studies of all incidences but may be contraindicated in cases of severe pulmonary hypertension or major right-to-left shunts. The latter allows a better sequential study. Radionuclide ventilation-perfusion studies are one of the major advances in pediatric pneumology in recent years [fr

  18. Reversible defects on myocardial perfusion imaging early after coronary stent implantation: a predictor of late restenosis

    International Nuclear Information System (INIS)

    Kim, D. E.; Park, S. A.; Kim, C. K.; Chang, J. A.; Jeong, J. W.; Oh, S. G.; Lee, C.

    2007-01-01

    It appears logical that myocardial perfusion should be fixed and not reversible, in the territory supplied by a dilated coronary artery. However, several studies have demonstrated reversible perfusion in the territory supplied by a coronary artery with an optimally implanted stent. The main objective of this study was to evaluate the incidence of reversible defects detected by M-SPECT early after optimal PTCA with stent implantation. Its second objective was to determine the predictive value of detecting reversible defects after stent implantation for late restenosis. Sixty-six patients that underwent M-SPECT within 24 hours of successful PTCA with stent implantation were included. All patients were followed up clinically and angiographically. The incidence of reversible perfusion defects on M-SPECT and the rate of late restenosis in target coronary arteries were evaluated retrospectively. Reversible perfusion defects on M-SPECT were observed in 26% of the patients and in 36% of lesions following successful PTCA with stent implantation. The incidence of late restenosis was significantly higher in patients and lesions with reversible perfusion defects (47% vs. 18%). According to binary logistic regression analysis, the presence of a reversible perfusion defects was the only independent predictor of late restenosis. This study shows that the predictive value of reversible perfusion defects on M-SPECT early after stent implantation with respect to the incidence of late restenosis was 47% in patients with a reversible defect, and 18% in those without it

  19. Ventilation and Perfusion Lung Scintigraphy of Allergen-Induced Airway Responses in Atopic Asthmatic Subjects

    Directory of Open Access Journals (Sweden)

    Krishnan Parameswaran

    2007-01-01

    Full Text Available BACKGROUND: Both ventilation (V and perfusion (Q of the lungs are altered in asthma, but their relationships with allergen-induced airway responses and gas exchange are not well described.

  20. Regional distribution of ventilation and perfusion in patients with obstructive pulmonary disease and alpha/sub 1/-antitrypsin deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Mostafa, A B.M.G.; Tulley, N J; Harding, L K; Stockley, R A

    1983-08-01

    Regional distribution of pulmonary ventilation and perfusion has been determined of 13 patients with chronic obstructive pulmonary disease (COPD). Eight patients had alpha/sub 1/-antitrypsin deficiency (..cap alpha../sub 1/ATD). Ventilation studies were carried out using xenon-133 (/sup 133/Xe) and krypton-81m (sup(81m)Kr) gases. Trapping indices were determined from the wash-out part of the xenon ventilation studies. Results obtained from patients were compared with those of normal controls. Ventilation studies with sup(81m)Kr showed pulmonary changes more clearly than did /sup 133/Xe studies and the trapping of radio-xenon was more extensive in lung bases than in apices whether or not the patients had ..cap alpha../sub 1/ ATD. The distribution of perfusion followed a pattern similar to that of ventilation, but did not differ statistically from that of the normal controls.

  1. 99mTc-ECD brain SPECT in patients with Moyamoya disease: a reflection of cerebral perfusion status at tissue level in the disease process

    International Nuclear Information System (INIS)

    Kashyap, Raghava; Mittal, Bhagwant Rai; Sunil, Hejjaji Venkataramarao; Bhattacharya, Anish; Singh, Baljinder; Mukherjee, Kanchan Kumar; Gupta, Sunil Kumar

    2011-01-01

    Moyamoya disease is a rare, progressive cerebrovascular disorder caused by intracranial stenosis of the circle of Willis, resulting in successive ischemic events. Computed tomography (CT) and magnetic resonance imaging (MRI) play a major role in diagnosis. The aim of the study was to describe the spectrum of findings on brain SPECT in patients with Moyamoya disease and to compare the findings with other investigations. 99m Tc-ECD SPECT scans of seventeen patients (7 children and 10 adults) were analysed to study the brain perfusion. Features of Moyamoya disease were detected on DSA in 11 patients, CTA in one, MR angiography in one patient. Brain perfusion SPECT analysis showed unilateral perfusion defects in 11 patients, normal perfusion in 2 and bilateral defects in 4 patients. No perfusion defects despite bilateral vascular changes were noted in one patient. Cerebral infarcts were detected on MRI unilaterally in three subjects while multiple infarcts were identified in one. 99m Tc-ECD Brain SPECT showed perfusion defects that were more extensive compared to those detected on MRI. Post acetazolamide studies for assessment of cerebrovascular reserve were done in three patients. Two of them showed good cerebrovascular reserve (>1). Follow-up studies post-surgical procedures (Myo-dura synangiosis) done in two patients showed partial resolution of perfusion defects in the involved areas. Brain perfusion scintigraphy is an important adjunct in evaluation of patients with Moyamoya disease yielding information about the direct end results of the pathology in the vessels and also prognostic information. (author)

  2. Prevalence of symptomatic and silent stress-induced perfusion defects in diabetic patients with suspected coronary artery disease referred for myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Prior, John O.; Calcagni, Maria-Lucia; Bischof Delaloye, Angelika [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Monbaron, David; Ruiz, Juan [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland); Koehli, Melanie [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland)

    2005-01-01

    Silent myocardial ischaemia - as evaluated by stress-induced perfusion defects on myocardial perfusion scintigraphy (MPS) in patients without a history of chest pain - is frequent in diabetes and is associated with increased rates of cardiovascular events. Its prevalence has been determined in asymptomatic diabetic patients, but remains largely unknown in diabetic patients with suspected coronary artery disease (CAD) in the clinical setting. In this study we therefore sought (a) to determine the prevalence of symptomatic and silent perfusion defects in diabetic patients with suspected CAD and (b) to characterise the eventual predictors of abnormal perfusion. The patient population comprised 133 consecutive diabetic patients with suspected CAD who had been referred for MPS. Studies were performed with exercise (41%) or pharmacological stress testing (1-day protocol, {sup 99m}Tc-sestamibi, {sup 201}Tl or both). We used semi-quantitative analysis (20-segment polar maps) to derive the summed stress score (SSS) and the summed difference score (SDS). Abnormal MPS (SSS{>=}4) was observed in 49 (37%) patients (SSS=4.9{+-}8.4, SDS=2.4{+-}4.7), reversible perfusion defects (SDS{>=}2) in 40 (30%) patients [SSS=13.3{+-}10.9; SDS=8.0{+-}5.6; 20% moderate to severe (SDS>4), 7% multivessel] and fixed defects in 21 (16%) patients. Results were comparable between patients with and patients without a history of chest pain. Of 75 patients without a history of chest pain, 23 (31%, 95% CI=21-42%) presented reversible defects (SSS=13.9{+-}11.3; SDS=7.4{+-}1.2), indicative of silent ischaemia. Reversible defects were associated with inducible ST segment depression during MPS stress (odds ratio (OR)=3.2, p<0.01). Fixed defects were associated with erectile dysfunction in males (OR=3.7, p=0.02) and lower aspirin use (OR=0.25, p=0.02). Silent stress-induced perfusion defects occurred in 31% of the patients, a rate similar to that in patients with a history of chest pain. MPS could identify

  3. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    International Nuclear Information System (INIS)

    Thieme, Sven F.; Becker, Christoph R.; Hacker, Marcus; Nikolaou, Konstantin; Reiser, Maximilian F.; Johnson, Thorsten R.C.

    2008-01-01

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam

  4. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F.; Becker, Christoph R. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Hacker, Marcus [Department of Nuclear Medicine, Ludwig-Maximilians-University of Munich (Germany); Nikolaou, Konstantin; Reiser, Maximilian F. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Johnson, Thorsten R.C. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany)], E-mail: thorsten.johnson@med.uni-muenchen.de

    2008-12-15

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam.

  5. Ventilation and cardiac related impedance changes in children undergoing corrective open heart surgery

    International Nuclear Information System (INIS)

    Schibler, Andreas; Pham, Trang M T; Moray, Amol A; Stocker, Christian

    2013-01-01

    Electrical impedance tomography (EIT) can determine ventilation and perfusion relationship. Most of the data obtained so far originates from experimental settings and in healthy subjects. The aim of this study was to demonstrate that EIT measures the perioperative changes in pulmonary blood flow after repair of a ventricular septum defect in children with haemodynamic relevant septal defects undergoing open heart surgery. In a 19 bed intensive care unit in a tertiary children's hospital ventilation and cardiac related impedance changes were measured using EIT before and after surgery in 18 spontaneously breathing patients. The EIT signals were either filtered for ventilation (ΔZV) or for cardiac (ΔZQ) related impedance changes. Impedance signals were then normalized (normΔZV, normΔZQ) for calculation of the global and regional impedance related ventilation perfusion relationship (normΔZV/normΔZQ). We observed a trend towards increased normΔZV in all lung regions, a significantly decreased normΔZQ in the global and anterior, but not the posterior lung region. The normΔZV/normΔZQ was significantly increased in the global and anterior lung region. Our study qualitatively validates our previously published modified EIT filtration technique in the clinical setting of young children with significant left-to-right shunt undergoing corrective open heart surgery, where perioperative assessment of the ventilation perfusion relation is of high clinical relevance. (paper)

  6. Ventilation and cardiac related impedance changes in children undergoing corrective open heart surgery.

    Science.gov (United States)

    Schibler, Andreas; Pham, Trang M T; Moray, Amol A; Stocker, Christian

    2013-10-01

    Electrical impedance tomography (EIT) can determine ventilation and perfusion relationship. Most of the data obtained so far originates from experimental settings and in healthy subjects. The aim of this study was to demonstrate that EIT measures the perioperative changes in pulmonary blood flow after repair of a ventricular septum defect in children with haemodynamic relevant septal defects undergoing open heart surgery. In a 19 bed intensive care unit in a tertiary children's hospital ventilation and cardiac related impedance changes were measured using EIT before and after surgery in 18 spontaneously breathing patients. The EIT signals were either filtered for ventilation (ΔZV) or for cardiac (ΔZQ) related impedance changes. Impedance signals were then normalized (normΔZV, normΔZQ) for calculation of the global and regional impedance related ventilation perfusion relationship (normΔZV/normΔZQ). We observed a trend towards increased normΔZV in all lung regions, a significantly decreased normΔZQ in the global and anterior, but not the posterior lung region. The normΔZV/normΔZQ was significantly increased in the global and anterior lung region. Our study qualitatively validates our previously published modified EIT filtration technique in the clinical setting of young children with significant left-to-right shunt undergoing corrective open heart surgery, where perioperative assessment of the ventilation perfusion relation is of high clinical relevance.

  7. Exercise-induced thallium-201 myocardial perfusion defects in angina pectoris without significant coronary artery stenosis

    International Nuclear Information System (INIS)

    Nakazato, Masayasu; Maruoka, Yuji; Sunagawa, Osahiko; Kinjo, Kunihiko; Tomori, Masayuki; Fukiyama, Koshiro

    1990-01-01

    We performed exercise thallium-201 myocardial scintigraphy in 32 patients with angina pectoris to study the incidence of perfusion defects, who had no significant organic stenosis on coronary angiography. None of them had myocardial infarction or cardiomyopathy. Thallium-201 myocardial scintigraphy and 12-lead ECG recording were performed during supine bicycle ergometer exercise. Perfusion defects in thallium-201 scintigrams in SPECT images were assessed during visual analysis by two observers. In the coronary angiograms obtained during intravenous infusion of nitroglycerin, the luminal diameter of 75% stenosis or less in the AHA classification was regarded as an insignificant organic stenosis. Myocardial perfusion defects in the thallium-201 scintigrams were detected in eight (25%) of the 32 patients. Six of these eight patients had variant angina documented during spontaneous attacks with ST elevations in standard 12-lead ECGs. Perfusion defects were demonstrated at the inferior or infero-posterior regions in six patients, one of whom had concomitant anteroseptal defect. The defects were not always accompanied by chest pain. All but one patient demonstrating inferior or inferoposterior defects showed ST depression in leads II, III and aV F on their ECGs, corresponding to inferior wall ischemia. The exception was a case with right bundle branch block. Thus, 25% of the patients with angina pectoris, who had no evidence of significant organic stenosis on their coronary angiograms, exhibited exercise-induced perfusion defects in their thallium-201 scintigrams. Coronary spasms might have caused myocardial ischemia in these patients. (author)

  8. The relationship between ventilatory lung motion and pulmonary perfusion shown by ventilatory lung motion imaging

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Nakatsuka, Tatsuya; Yoshimura, Kazuhiko; Hirose, Yoshiki; Hirayama, Jiro; Kobayashi, Toshio; Handa, Kenjiro

    1991-01-01

    Using ventilatory lung motion imaging, which was obtained from two perfusion lung scintigrams with 99m Tc-macroaggregated albumin taken in maximal inspiration and maximal expiration, the lung motion (E-I/I) of the each unilateral lung was studied in various cardiopulmonary diseases. The sum of (E-I)/I(+) of the unilateral lung was decreased in the diseased lung for localized pleuropulmonary diseases, including primary lung cancer and pleural thickening, and in both lungs for heart diseases, and diffuse pulmonary diseases including diffuse interstitial pneumonia and diffuse panbronchiolitis. The sum of (E-I)/I(+) of the both lungs, which correlated with vital capacity and PaO 2 , was decreased in diffuse interstitial pneumonia, pulmonary emphysema, diffuse panbronchiolitis, primary lung cancer, pleural diseases and so on. (E-I)/I(+), correlated with pulmonary perfusion (n=49, r=0.51, p 81m Kr or 133 Xe (n=49, r=0.61, p<0.001) than pulmonary perfusion. The ventilatory lung motion imaging, which demonstrates the motion of the intra-pulmonary areas and lung edges, appears useful for estimating pulmonary ventilation of the perfused area as well as pulmonary perfusion. (author)

  9. Ventilation/perfusion SPECT/CT in patients with pulmonary emphysema. Evaluation of software-based analysing.

    Science.gov (United States)

    Schreiter, V; Steffen, I; Huebner, H; Bredow, J; Heimann, U; Kroencke, T J; Poellinger, A; Doellinger, F; Buchert, R; Hamm, B; Brenner, W; Schreiter, N F

    2015-01-01

    The purpose of this study was to evaluate the reproducibility of a new software based analysing system for ventilation/perfusion single-photon emission computed tomography/computed tomography (V/P SPECT/CT) in patients with pulmonary emphysema and to compare it to the visual interpretation. 19 patients (mean age: 68.1 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. Data were analysed by two independent observers in visual interpretation (VI) and by software based analysis system (SBAS). SBAS PMOD version 3.4 (Technologies Ltd, Zurich, Switzerland) was used to assess counts and volume per lung lobe/per lung and to calculate the count density per lung, lobe ratio of counts and ratio of count density. VI was performed using a visual scale to assess the mean counts per lung lobe. Interobserver variability and association for SBAS and VI were analysed using Spearman's rho correlation coefficient. Interobserver agreement correlated highly in perfusion (rho: 0.982, 0.957, 0.90, 0.979) and ventilation (rho: 0.972, 0.924, 0.941, 0.936) for count/count density per lobe and ratio of counts/count density in SBAS. Interobserver agreement correlated clearly for perfusion (rho: 0.655) and weakly for ventilation (rho: 0.458) in VI. SBAS provides more reproducible measures than VI for the relative tracer uptake in V/P SPECT/CTs in patients with pulmonary emphysema. However, SBAS has to be improved for routine clinical use.

  10. Validation and absolute quantification of MR perfusion compared with CT perfusion in patients with unilateral cerebral arterial stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, Fang-Ying, E-mail: fychiou@hotmail.com [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei City, Taiwan (China); Kao, Yi-Hsuan, E-mail: yhkao@ym.edu.tw [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei City, Taiwan (China); Teng, Michael Mu Huo, E-mail: mhteng@gmail.com [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei City, Taiwan (China); School of Medicine, National Yang-Ming University, Taipei City, Taiwan (China); Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan (China); Chung, Hsiao-Wen, E-mail: chung@cc.ee.ntu.edu.tw [Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan (China); Chang, Feng-Chi, E-mail: fcchang374@gmail.com [School of Medicine, National Yang-Ming University, Taipei City, Taiwan (China); Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan (China); Cho, I-Chieh, E-mail: jessie8030@yahoo.com.tw [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei City, Taiwan (China); Chen, Wen-Chun, E-mail: sky7408695@hotmail.com [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei City, Taiwan (China)

    2012-12-15

    Objective: The aim of the study was to assess absolute quantification of dynamic susceptibility contrast-enhanced magnetic resonance perfusion (MRP) comparing with computed tomography perfusion (CTP) in patients with unilateral stenosis. Materials and methods: We retrospectively post-processed MRP in 20 patients with unilateral occlusion or stenosis of >79% at the internal carotid artery or the middle cerebral artery (MCA). Absolute quantification of MRP was performed after applying the following techniques: cerebrospinal fluid removal, vessel removal, and automatic segmentation of brain to calculate the scaling factors to convert relative cerebral blood volume (rCBV) and relative cerebral blood flow (rCBF) values to absolute values. For comparison between MRP and CTP, we manually deposited regions of interest in bilateral MCA territories at the level containing the body of the lateral ventricle. Results: The correlation between MRP and CTP was best for mean transit time (MTT) (r = 0.83), followed by cerebral blood flow (CBF) (r = 0.52) and cerebral blood volume (CBV) (r = 0.43). There was no significant difference between CTP and MRP for CBV, CBF, and MTT on the lesion side, the contralateral side, the lesion-contralateral differences, or the lesion-to-contralateral ratios (P > 0.05). The mean differences between MRP and CTP were as follows: CBV −0.57 mL/100 g, CBF 2.50 mL/100 g/min, and MTT −0.90 s. Conclusion: Absolute quantification of MRP is possible. Using the proposed method, measured values of MRP and CTP had acceptable linear correlation and quantitative agreement.

  11. Validation and absolute quantification of MR perfusion compared with CT perfusion in patients with unilateral cerebral arterial stenosis

    International Nuclear Information System (INIS)

    Chiu, Fang-Ying; Kao, Yi-Hsuan; Teng, Michael Mu Huo; Chung, Hsiao-Wen; Chang, Feng-Chi; Cho, I-Chieh; Chen, Wen-Chun

    2012-01-01

    Objective: The aim of the study was to assess absolute quantification of dynamic susceptibility contrast-enhanced magnetic resonance perfusion (MRP) comparing with computed tomography perfusion (CTP) in patients with unilateral stenosis. Materials and methods: We retrospectively post-processed MRP in 20 patients with unilateral occlusion or stenosis of >79% at the internal carotid artery or the middle cerebral artery (MCA). Absolute quantification of MRP was performed after applying the following techniques: cerebrospinal fluid removal, vessel removal, and automatic segmentation of brain to calculate the scaling factors to convert relative cerebral blood volume (rCBV) and relative cerebral blood flow (rCBF) values to absolute values. For comparison between MRP and CTP, we manually deposited regions of interest in bilateral MCA territories at the level containing the body of the lateral ventricle. Results: The correlation between MRP and CTP was best for mean transit time (MTT) (r = 0.83), followed by cerebral blood flow (CBF) (r = 0.52) and cerebral blood volume (CBV) (r = 0.43). There was no significant difference between CTP and MRP for CBV, CBF, and MTT on the lesion side, the contralateral side, the lesion-contralateral differences, or the lesion-to-contralateral ratios (P > 0.05). The mean differences between MRP and CTP were as follows: CBV −0.57 mL/100 g, CBF 2.50 mL/100 g/min, and MTT −0.90 s. Conclusion: Absolute quantification of MRP is possible. Using the proposed method, measured values of MRP and CTP had acceptable linear correlation and quantitative agreement.

  12. Large cerebral perfusion defects observed in brain perfusion SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients

    Energy Technology Data Exchange (ETDEWEB)

    So, Young; Kim, Hahn Young; Roh, Hong Gee; Han, Seol Heui [Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2007-07-01

    Transient global amnesia (TGA) is a memory disorder characterized by an episode of antegrade amnesia and bewilderment which persists for several hours. We analyzed brain perfusion SPECT findings and clinical outcome of patients who suffered from TGA. From September 2005 to August 2007, 12 patients underwent Tc-99m ECD brain perfusion SPECT for neuroimaging of TGA. All patients also underwent MRI and MRA including DWI (MRI). Among them, 10 patients who could be chased more than 6 months were included in this study. Their average age was 60.74.0 yrs (M: F = 2: 8) and the average duration of amnesia was 4.42.2 hrs (1 hr {approx} 7 hrs). Duration from episode of amnesia to SPECT was 4.32.4 days (1{approx}9 days). Precipitating factors could be identified in 6 patients: emotional stress 3, hair dyeing 1, taking a nap 1 and angioplasty 1. SPECT and MRI was visually assessed, No cerebral perfusion defect was observed on SPECT in 3 patients and their clinical outcome was all good. Among 7 patients who had cerebral perfusion defects on SPECT, 3 patients had good clinical outcome, while others did not: one had hypercholesterolemia, another had depression, and 2 patients with cerebral perfusion defects at both temporoparetal cortex was later diagnosed as early Alzheimer's disease (AD) and mild cognitive impairment (MCI). MRI was negative in 6 patients and 3 of them had excellent clinical outcome while other 3 were diagnosed as hypercholesterolemia, early AD and MCI. Among 4 patients with positive MRI, 3 showed good clinical outcome and their MRI showed lesions at medial temporal cortex and/or vertebral artery. One patient with microcalcification at left putamen was diagnosed to have depression. Large cerebral perfusion defects on SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients which usually shows negative MRI.

  13. Large cerebral perfusion defects observed in brain perfusion SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients

    International Nuclear Information System (INIS)

    So, Young; Kim, Hahn Young; Roh, Hong Gee; Han, Seol Heui

    2007-01-01

    Transient global amnesia (TGA) is a memory disorder characterized by an episode of antegrade amnesia and bewilderment which persists for several hours. We analyzed brain perfusion SPECT findings and clinical outcome of patients who suffered from TGA. From September 2005 to August 2007, 12 patients underwent Tc-99m ECD brain perfusion SPECT for neuroimaging of TGA. All patients also underwent MRI and MRA including DWI (MRI). Among them, 10 patients who could be chased more than 6 months were included in this study. Their average age was 60.74.0 yrs (M: F = 2: 8) and the average duration of amnesia was 4.42.2 hrs (1 hr ∼ 7 hrs). Duration from episode of amnesia to SPECT was 4.32.4 days (1∼9 days). Precipitating factors could be identified in 6 patients: emotional stress 3, hair dyeing 1, taking a nap 1 and angioplasty 1. SPECT and MRI was visually assessed, No cerebral perfusion defect was observed on SPECT in 3 patients and their clinical outcome was all good. Among 7 patients who had cerebral perfusion defects on SPECT, 3 patients had good clinical outcome, while others did not: one had hypercholesterolemia, another had depression, and 2 patients with cerebral perfusion defects at both temporoparetal cortex was later diagnosed as early Alzheimer's disease (AD) and mild cognitive impairment (MCI). MRI was negative in 6 patients and 3 of them had excellent clinical outcome while other 3 were diagnosed as hypercholesterolemia, early AD and MCI. Among 4 patients with positive MRI, 3 showed good clinical outcome and their MRI showed lesions at medial temporal cortex and/or vertebral artery. One patient with microcalcification at left putamen was diagnosed to have depression. Large cerebral perfusion defects on SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients which usually shows negative MRI

  14. Prevalence of symptomatic and silent stress-induced perfusion defects in diabetic patients with suspected coronary artery disease referred for myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Prior, John O.; Calcagni, Maria-Lucia; Bischof Delaloye, Angelika; Monbaron, David; Ruiz, Juan; Koehli, Melanie

    2005-01-01

    Silent myocardial ischaemia - as evaluated by stress-induced perfusion defects on myocardial perfusion scintigraphy (MPS) in patients without a history of chest pain - is frequent in diabetes and is associated with increased rates of cardiovascular events. Its prevalence has been determined in asymptomatic diabetic patients, but remains largely unknown in diabetic patients with suspected coronary artery disease (CAD) in the clinical setting. In this study we therefore sought (a) to determine the prevalence of symptomatic and silent perfusion defects in diabetic patients with suspected CAD and (b) to characterise the eventual predictors of abnormal perfusion. The patient population comprised 133 consecutive diabetic patients with suspected CAD who had been referred for MPS. Studies were performed with exercise (41%) or pharmacological stress testing (1-day protocol, 99m Tc-sestamibi, 201 Tl or both). We used semi-quantitative analysis (20-segment polar maps) to derive the summed stress score (SSS) and the summed difference score (SDS). Abnormal MPS (SSS≥4) was observed in 49 (37%) patients (SSS=4.9±8.4, SDS=2.4±4.7), reversible perfusion defects (SDS≥2) in 40 (30%) patients [SSS=13.3±10.9; SDS=8.0±5.6; 20% moderate to severe (SDS>4), 7% multivessel] and fixed defects in 21 (16%) patients. Results were comparable between patients with and patients without a history of chest pain. Of 75 patients without a history of chest pain, 23 (31%, 95% CI=21-42%) presented reversible defects (SSS=13.9±11.3; SDS=7.4±1.2), indicative of silent ischaemia. Reversible defects were associated with inducible ST segment depression during MPS stress (odds ratio (OR)=3.2, p<0.01). Fixed defects were associated with erectile dysfunction in males (OR=3.7, p=0.02) and lower aspirin use (OR=0.25, p=0.02). Silent stress-induced perfusion defects occurred in 31% of the patients, a rate similar to that in patients with a history of chest pain. MPS could identify these patients with a

  15. Pulmonary Perfusion and Ventilation During Cardiopulmonary Bypass Are Not Associated with Improved Postoperative Outcomes After Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Yiliam F Rodriguez-Blanco

    2016-11-01

    Full Text Available ObjectivesClinical trials of either pulmonary perfusion or ventilation during cardiopulmonary bypass are equivocal. We hypothesized that to achieve significant improvement in outcomes both interventions had to be concurrent.DesignRetrospective case-control studySettingsMajor academic tertiary referral medical centerParticipants274 consecutive patients who underwent open heart surgery with cardiopulmonary bypass 2009 - 2013.InterventionsThe outcomes of 86 patients who received pulmonary perfusion and ventilation during cardiopulmonary bypass were retrospectively compared to the control group of 188 patients.Measurements and Main ResultsRespiratory complications rates were similar in both groups (33.7% vs. 33.5%, as were the rates of postoperative pneumonia (4.7% vs. 4.3%, pleural effusions (13.9% vs. 12.2% and re-intubations (9.3% vs. 9.1%. Rates of adverse postoperative cardiac events including ventricular tachycardia (9.3% vs. 8.5% and atrial fibrillation (33.7% vs. 28.2% were equivalent in both groups. Incidence of sepsis (8.1% vs. 5.3%, postoperative stroke (2.3% vs. 2.1%, acute kidney injury (2.3% vs. 3.7% and renal failure (5.8% vs. 3.7% were likewise comparable. Despite similar transfusion requirements, coagulopathy (12.8% vs. 5.3%, p=0.031 and the need for mediastinal re-exploration (17.4% vs. 9.6%, p=0.0633 were observed more frequently in the pulmonary perfusion and ventilation group, but the difference did not reach the statistical significance. ICU and hospital stays, and the ICU readmission rates (7.0% vs. 8.0% were similar in both groups.ConclusionsSimultaneous pulmonary perfusion and ventilation during cardiopulmonary bypass were not associated with improved clinical outcomes.

  16. 99mTc-DTPA aerosol for same-day post-perfusion ventilation imaging: Results of a multicentre study

    International Nuclear Information System (INIS)

    Koehn, H.; Koenig, B.; Bachmayr, S.; Markt, B.; Eber, O.; Lind, P.; Galvan, G.; Rettenbacher, L.; Holm, C.; Ogris, E.

    1993-01-01

    A multicentre study was performed in an attempt to evaluate a submicronic technetium-99m diethylene triamine penta-acetic acid aerosol generated by a newly developed delivery system, the aerosol production equipment (APE nebulizer), for same-day post-perfusion ventilation imaging in patients with clinically suspected pulmonary embolism. Quantitative comparison between the DTPA aerosol and krypton gas demonstrated a close correlation with respect to regional pulmonary distribution of activity and peripheral lung penetration (n=14, r=0.94, P 99m Tc-labelled DTPA aerosol is well suited for fast same-day post-perfusion ventilation imaging in patients with clinical suspicion of pulmonary embolism. (orig.)

  17. Automatic delineation of functional lung volumes with 68Ga-ventilation/perfusion PET/CT.

    Science.gov (United States)

    Le Roux, Pierre-Yves; Siva, Shankar; Callahan, Jason; Claudic, Yannis; Bourhis, David; Steinfort, Daniel P; Hicks, Rodney J; Hofman, Michael S

    2017-10-10

    Functional volumes computed from 68 Ga-ventilation/perfusion (V/Q) PET/CT, which we have shown to correlate with pulmonary function test parameters (PFTs), have potential diagnostic utility in a variety of clinical applications, including radiotherapy planning. An automatic segmentation method would facilitate delineation of such volumes. The aim of this study was to develop an automated threshold-based approach to delineate functional volumes that best correlates with manual delineation. Thirty lung cancer patients undergoing both V/Q PET/CT and PFTs were analyzed. Images were acquired following inhalation of Galligas and, subsequently, intravenous administration of 68 Ga-macroaggreted-albumin (MAA). Using visually defined manual contours as the reference standard, various cutoff values, expressed as a percentage of the maximal pixel value, were applied. The average volume difference and Dice similarity coefficient (DSC) were calculated, measuring the similarity of the automatic segmentation and the reference standard. Pearson's correlation was also calculated to compare automated volumes with manual volumes, and automated volumes optimized to PFT indices. For ventilation volumes, mean volume difference was lowest (- 0.4%) using a 15%max threshold with Pearson's coefficient of 0.71. Applying this cutoff, median DSC was 0.93 (0.87-0.95). Nevertheless, limits of agreement in volume differences were large (- 31.0 and 30.2%) with differences ranging from - 40.4 to + 33.0%. For perfusion volumes, mean volume difference was lowest and Pearson's coefficient was highest using a 15%max threshold (3.3% and 0.81, respectively). Applying this cutoff, median DSC was 0.93 (0.88-0.93). Nevertheless, limits of agreement were again large (- 21.1 and 27.8%) with volume differences ranging from - 18.6 to + 35.5%. Using the 15%max threshold, moderate correlation was demonstrated with FEV1/FVC (r = 0.48 and r = 0.46 for ventilation and perfusion images, respectively

  18. Value of the ventilation/perfusion scan in acute pulmonary embolism: Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED)

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    To determine the sensitivities and specificities of ventilation/perfusion lung scans for acute pulmonary embolism, a random sample of 933 of 1,493 patients was studied prospectively. Nine hundred thirty-one underwent scintigraphy and 755 underwent pulmonary angiography; 251 (33%) of 755 demonstrated pulmonary embolism. Almost all patients with pulmonary embolism had abnormal scans of high, intermediate, or low probability, but so did most without pulmonary embolism. Of 116 patients with high-probability scans and definitive angiograms, 102 (88%) had pulmonary embolism, but only a minority with pulmonary embolism had high-probability scans. Of 322 with intermediate-probability scans and definitive angiograms, 105 (33%) had pulmonary embolism. Follow-up and angiography together suggest pulmonary embolism occurred among 12% of patients with low-probability scans. Clinical assessment combined with the ventilation/perfusion scan established the diagnosis or exclusion of pulmonary embolism only for a minority of patients--those with clear and concordant clinical and ventilation/perfusion scan findings

  19. An exercise in preferential unilateral breathing

    International Nuclear Information System (INIS)

    Cheong, D.; Tucker, B.; Jenkins, S.; Robinson, P.; Curtin University, Shenton Park, WA

    1999-01-01

    Full text: In preparation for major thoracic surgery, physiotherapists have traditionally taught unilateral breathing exercises. There are no studies that prove that these exercises are effective This study was undertaken to demonstrate the effects of unilateral thoracic expansion exercises (TEE) using 99 Tc m -Technegas Ten physiotherapists were taught unilateral TEE to increase ventilation to the right lower lobe. Each subject underwent two separate Technegas ventilation studies using a single-breath technique, one with normal deep inspiration and the other during a right TEE. Dynamic and static images were acquired in the seated position for each ventilation study. Analysis was undertaken by dividing the lungs into 6 zones of equal height and calculating the relative ventilation of each zone and each lung. Seven subjects (70%) achieved significantly increased ventilation to the right lower zone, while 9 (90%) achieved greater ventilation to the right lung. Total lung ventilation was reduced during right TEE when compared with normal deep inspiration

  20. Relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism: assessment with breath-hold SPECT-CT pulmonary angiography fusion images.

    Science.gov (United States)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi

    2008-09-01

    The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.

  1. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    International Nuclear Information System (INIS)

    Suga, K.; Yasuhiko, K.; Iwanaga, H.; Tokuda, O.; Matsunaga, N.

    2009-01-01

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  2. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Suga, K.; Yasuhiko, K. (Dept. of Radiology, St. Hill Hospital, Ube, Yamaguchi (Japan)); Iwanaga, H.; Tokuda, O.; Matsunaga, N. (Dept. of Radiology, Yamaguchi Univ. School of Medicine, Ube, Yamaguchi (Japan))

    2009-01-15

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  3. Functional mechanism of lung mosaic CT attenuation: assessment with deep-inspiration breath-hold perfusion SPECT-CT fusion imaging and non-breath-hold Technegas SPECT.

    Science.gov (United States)

    Suga, K; Yasuhiko, K; Iwanaga, H; Tokuda, O; Matsunaga, N

    2009-01-01

    The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Although further validation is required, our results indicate that heterogeneous pulmonary arterial

  4. A rare combination of cardiopulmonary anomalies demonstrated on ventilation-perfusion scan

    International Nuclear Information System (INIS)

    Khan, S.; Dunn, J.; Al-Nahhas, A.; Ariff, B.; Juli, C.; Karunanithy, N.; Strickland, N.

    2008-01-01

    In this case report we describe an unusual appearance seen on a ventilation-perfusion (V/Q) scan in a woman with pulmonary hypertension. Although the pulmonary hypertension was not caused by pulmonary emboli, the V/Q scan suggested several cardiac anomalies which may lead to pulmonary hypertension. Most of the cardiac anomalies, including right-sided aortic arch and right-to-left shunt, can be deduced from careful examination of the V/Q scan. A subsequent cardiac MRI scan confirmed the anomalies. (authors)

  5. The predictive value of preoperative perfusion/ventilation scintigraphy, spirometry and x-ray of the lungs on postoperative pulmonary complications. A prospective study

    International Nuclear Information System (INIS)

    Fogh, J.; Wille-Joergensen, P.; Brynjolf, I.; Thorup, J.; Joergensen, T.; Bording, L.; Kjaergaard, J.

    1987-01-01

    Prospectively, 125 patients were examined with 99m Tc-perfusion scintigraphy, 89m Kr- or 127 Xe-ventilation scintigraphy and chest radiogram prior to major surgery. Postoperative therapy-demanding pulmonary complications occurred in 18% of the patients. A statistical association could be demonstrated between all the preoperative tests except ventilation scintigraphy and the frequency of complications. However, the predictive values of each of the tests, or even the combined results, were not significantly different from the frequency of complications among all the patients. It is concluded that the predictive values of perfusion-and ventilation scintigraphy, spirometry and radiogram of the chest are too low to be of any practical use. (author)

  6. Non-contrast-enhanced perfusion and ventilation assessment of the human lung by means of fourier decomposition in proton MRI.

    Science.gov (United States)

    Bauman, Grzegorz; Puderbach, Michael; Deimling, Michael; Jellus, Vladimir; Chefd'hotel, Christophe; Dinkel, Julien; Hintze, Christian; Kauczor, Hans-Ulrich; Schad, Lothar R

    2009-09-01

    Assessment of regional lung perfusion and ventilation has significant clinical value for the diagnosis and follow-up of pulmonary diseases. In this work a new method of non-contrast-enhanced functional lung MRI (not dependent on intravenous or inhalative contrast agents) is proposed. A two-dimensional (2D) true fast imaging with steady precession (TrueFISP) pulse sequence (TR/TE = 1.9 ms/0.8 ms, acquisition time [TA] = 112 ms/image) was implemented on a 1.5T whole-body MR scanner. The imaging protocol comprised sets of 198 lung images acquired with an imaging rate of 3.33 images/s in coronal and sagittal view. No electrocardiogram (ECG) or respiratory triggering was used. A nonrigid image registration algorithm was applied to compensate for respiratory motion. Rapid data acquisition allowed observing intensity changes in corresponding lung areas with respect to the cardiac and respiratory frequencies. After a Fourier analysis along the time domain, two spectral lines corresponding to both frequencies were used to calculate the perfusion- and ventilation-weighted images. The described method was applied in preliminary studies on volunteers and patients showing clinical relevance to obtain non-contrast-enhanced perfusion and ventilation data.

  7. Lung perfusion and ventilation scintigraphy in pre- and postoperative diagnostics; Lungenperfusions- und Ventilationsszintigraphie in der prae- und postoperativen Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Sandrock, D.; Munz, D.L. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Charite, Medizinische Fakultaet der Humboldt-Univ. zu Berlin (Germany)

    1998-03-01

    Lung perfusion (Tc-99m labeled albumin particles) and ventilation (Xe-133 gas) are used prior to thoracic surgery in order to evaluate changes in perfusion and ventilation due to the underlying diseases. Furthermore, perfusion scintigraphy allows combined with spirometry the prediction of the postinterventional vital capacity and the forced expiratory volume in 1 s. The correlation coefficient for this procedure compared with values measured postoperatively are in the range of 0.8. The method allows the assessment of operability in terms of postinterventional function. (orig.) [Deutsch] Die Lungenperfusions- (mit Tc-99m-markierten Albuminpartikeln) und die Ventilationsszintigraphie (mit Xe-133 als Gas) werden vor thoraxchirugrischen Eingriffen zur Beurteilung der durch die Grund- oder weitere Erkrankungen bedingte Einschraenkungen von Perfusion und Belueftung eingesetzt. Die Perfusionsszintigraphie erlaubt in Kombination mit der Spirometrie ausserdem die Vorausberechnung der postoperativ zu erwartenden Vitalkapazitaet und des forcierten exspiratorischen Erstsekundenvolumens. Im Vergleich mit den postoperativ gemessenen Volumina liegen die Korrelationskoeffizienten um 0,8. Die Methode ermoeglicht daher eine Beurteilung der Operabilitaet bezueglich der postoperativen Lungenfunktion. (orig.)

  8. Lung ventilation-perfusion scintigraphy in children on long-term parenteral nutrition

    Energy Technology Data Exchange (ETDEWEB)

    Pifarre, Paloma; Roca, Isabel [Universitat Autonoma de Barcelona, Department of Nuclear Medicine, Hospital de la Vall d' Hebron, Barcelona (Spain); Irastorza, Inaki; Hill, Susan [Great Ormond Street Hospital, Department of Gastroenterology, London (United Kingdom); Simo, Marc [Instituto Universitario Dexeus, Department of Nuclear Medicine, Barcelona (Spain); Biassoni, Lorenzo; Gordon, Isky [Great Ormond Street Hospital, Department of Nuclear Medicine, London (United Kingdom)

    2009-06-15

    Pulmonary emboli (PE) are one of the major complications associated with total parenteral nutrition (TPN). Ventilation-perfusion scintigraphy (V/Q) remains the most used test for the diagnosis of PE and follow-up of patients on TPN. The aim of our study was to demonstrate the high prevalence of undiagnosed PE in children on TPN. The medical and imaging files of 64 patients on TPN who underwent V/Q examinations covering the period of 1986-2004 were reviewed. Children were aged between 3.18 months and 21.6 years. TPN was started at birth (range 0-15 years). All children had a normal chest radiograph and no symptoms at the time of the V/Q scan. A comparative analysis between the prevalence of PE and risk factors number of days per week with lipophilic content of the TPN, bowel inflammation and thrombophilic factors (protein C and S) was performed. Of the 64 patients, 25 (39%) had an abnormal V/Q scan. A total of 29 PE episodes were diagnosed in all patients. Two children had three episodes of PE. The median age at PE diagnosis was 4.6 years. In 17 patients (68%) diagnosis was achieved on the first V/Q scan performed. PE was bilateral in 56% and unilateral in 44%. PE was the main cause of 2 out 15 recorded deaths. All risk factors were associated with an increase in PE prevalence by statistical analysis. PE is underdiagnosed in children on long-term TPN. Lung V/Q scintigraphy is useful in the diagnosis of PE in children with a low pretest probability. (orig.)

  9. Association between left ventricular perfusion defects and myocardial deformation indexes in heart transplantation recipients.

    Science.gov (United States)

    D'Andrea, Antonello; De Rimini, Maria Luisa; America, Raffaella; Cirillo, Chiara; Riegler, Lucia; Limongelli, Giuseppe; D'Alto, Michele; Salerno, Gemma; Maiello, Ciro; Muto, Pietro; Russo, Maria Giovanna; Calabrò, Raffaele; Bossone, Eduardo; Pacileo, Giuseppe

    2017-10-01

    The aim of the study was to analyze possible correlations between strain echocardiography (STE) and PET myocardial perfusion in a population of heart transplantation (HTx) recipients showing preserved left ventricular (LV) ejection fraction. By STE, LV global longitudinal strain (LV GLS) was lower in HTx. PET showed no transient or chronic ischemia in 83 of 115 HTx (73%). Fixed perfusion defects were observed in 17% of HTx and reversible ischemia in 10%. Significant coronary stenosis was observed only in 10 cases. GLS was independently associated with age at HTx and fixed perfusion defects (HR 0.41; P<.001). Such relationships underline STE ability to early identify HTx pts with subclinical myocardial dysfunction during long-term follow-up. © 2017, Wiley Periodicals, Inc.

  10. Study on incidence of pulmonary embolism in patients with cardiac pacemakers using lung perfusion mapping and ventilation scanning

    International Nuclear Information System (INIS)

    Yamashina, Hideki; Higo, Masanori; Sueda, Takashi

    1990-01-01

    We investigated pulmonary perfusion mapping and ventilation scanning employing 99mTC-MMA and 81mKr-Gas in patients with DDD and VVI cardiac pacemaker implantation. In 51 cases among 175 patients we observed some defects which matched the results from lung perfusion scanning in the pulmonary segments and sub-segments. These were diagnosed as pulmonary embolism after the possibility of other pulmonary diseases was rejected. The incidence rate of pulmonary embolism in patients with VVI (Ventricular pacing/sensing, inhibited type) pacemakers was 47 out of 138, or 34.1%, especially for those who received a pulmonary scanning examination whithin 6 months after pacemaker implantation. In contrast, those who were examined after 6 months had lower rates as well as chronological factors. The incidence rate of pulmonary embolism in 37 patients with DDD (Double chamber pacing/sensing, double modes of response) pacemakers was 10.8%, considerably lower than that for patients with VVI pacemakers. Therefore, one main factor of pulmonary embolism in patients with pacemakers could be the non-physiological phase of the contractions of both atria and ventricles. Other factors, such as the presence of foreign bodies in the endocardium, aging, and hypertension, could also promote pulmonary embolism. (author)

  11. Kombineret ventilations/perfusions-SPECT/CT er bedst til diagnostik af lungeemboli

    DEFF Research Database (Denmark)

    Gutte Borgwardt, Henrik; Mortensen, Jann; Kristoffersen, Ulrik Sloth

    2012-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer test and imaging with either lung scintigraphy or pulmonary multidetector computed tomography angiography (CTA). Which of the two methods to use in PE diagnostic has not been determined...... and very limited data comparing these modalities are available. With the use of hybrid scanners, ventilation/perfusion-single-photon-emission-tomography (V/Q-SPECT) in combination with low-dose CT without contrast enhancement is feasible and should probably be considered first-line imaging in diagnosing PE....

  12. Krypton 81m and xenon 133 for complementary ventilation imaging in pulmonary perfusion studies: a clinical comparison. Chapter 12

    International Nuclear Information System (INIS)

    Weber, P.M.; Remedios, L.V.dos.

    1978-01-01

    Twenty-four patients with suspected pulmonary embolism were studied to determine the relative usefulness of 133 Xe and 81 Krsup(m) as indicators of pulmonary ventilation in complementing perfusion studies. In most cases, where krypton produced results superior to xenon, this could be attributed to better resolution of the 190 keV photon and to the fact that multiple views could be obtained, with each view paired precisely with a corresponding perfusion image, the direct result of the ease of use of krypton and its short 13 second half-life. This was well demonstrated in both of the patients with presumed pulmonary embolism and co-existing other pulmonary disease in which the results with xenon and krypton differed. In each case the mis-match was obscured by closely related areas of delayed xenon wash-out. In those patients where xenon demonstrated greater sensitivity in identifying areas of pulmonary disease, the lesions noted on wash-out appeared as areas of positive activity, while with krypton the defects were always photogenic and, when small probably obscured by scatter from adjacent normal activity. In the patient who might have been improperly categorized as a mis-match without the krypton study, the xenon study may have been normal because of inadequate equilibration time. (author)

  13. Electron beam CT diagnosis of congenital unilateral absence of pulmonary artery

    International Nuclear Information System (INIS)

    Zhou Yuan; Dai Ruping; Cao Cheng; Zhang Gejun; Jing Baolian

    2003-01-01

    Objective: To evaluate the clinical value of electron beam CT (EBCT) in diagnosing congenital unilateral absence of pulmonary artery (UAPA). Methods: Patients with clinically suspected pulmonary artery disease or primary pulmonary hypertension underwent EBCT scanning. EBCT confirmed the diagnosis of UAPA in 11 patients, who were also evaluated with echocardiography and chest roentgenography. Cardioangiography and nuclear ventilation-perfusion scan were performed in some patients for a comparative study. Results: 4 female adults had UAPA with out associated congenital anomaly. 3 male children with coexisting complex congenital abnormality had unilateral absence of the left pulmonary artery and 4 patients coexisted other simple cardiovascular anomaly. EBCT scanning simultaneously displayed topographic pattern of both unilateral absence of pulmonary artery and coexisting congenital cardiovascular anomaly, as well as lung diseases. Conclusion: UAPA diagnosed in childhood usually has unilateral absence of the left pulmonary artery and associated congenital cardiovascular anomaly, while UAPA diagnosed in adult usually has UAPA on the right side without associated congenital anomaly. EBCT is one of the optimal imaging techniques in diagnosing UAPA and it greatly increases the diagnostic efficacy than echocardiography dose. Both EBCT and cardioangiography have their own advantages, however, EBCT, as a noninvasive method, should be complementary and not exclusive

  14. Study of regional lung ventilation and perfusion by xenon 133

    International Nuclear Information System (INIS)

    Lombard, Yves.

    1976-01-01

    The present work consists of a regional lung exploration after injection of xenon 133, dissolved in physiological serum, followed a few minutes later by that of 99m Tc-labelled serumalbumin microspheres. The aim is three fold: first of all to study perfusion and ventilation by xenon 133, next to compare the results obtained after xenon 133 and 99 m Tc-labelled microsphere injection, lastly to establish the value of the technique and its routine application. This examination has not solved all problems of lung exploration by xenon 133. For example we deliberately kept to intraveinous injection of the gas dissolved in physiological serum, leaving aside the breathing test. Xenon 133 scintigraphy in our opinion will not tend to replace 99m Tc-labelled microsphere scintigraphy, which has irreplaceable morphological qualities, but will serve as an excellent complement. The basic advantage of xenon 133 is the regional ventilation estimate it provides allowing any anomaly of the lung parenchyma to be located immediately or conversely the functional value of the healthy lung to be established with a view to a surgical removal of a diseased zone [fr

  15. Evaluation of pN factors in patients with primary lung cancer by using perfusion, inhalation and ventilation studies

    International Nuclear Information System (INIS)

    Tamai, Toyosato; Tanabe, Masatada; Satoh, Katashi

    1987-01-01

    The interpretation of scintigraphic patterns and the role of pathophysiological mechanisms in patients with primary lung cancer were investigated. To determine the relative roles of perfusion, inhalation and ventilation scintigraphy, the relationship between the count ratio of the affected side to the healthy side and the post-surgical histological lymph nodes factors were observed in this study. These scintigraphic count ratio's in patients with primary lung cancer did not reflect the pN factors except in the perfusion study in patients with hilar primary lung cancer. (author)

  16. The uptake and metabolism of cystamine and taurine by isolated, ventilated and perfused rat and rabbit lungs

    International Nuclear Information System (INIS)

    Sharma, R.; Kodavanti, U.P.; Smith, L.L.; Mehendale, H.M.

    1991-01-01

    Cystamine has been reported to be taken up by the lung slices and metabolized to taurine via hypotaurine through enzymatic processes. The objective of these studies was to determine whether intact isolated, ventilated and perfused rat and rabbit lungs also posses similar characteristics. The lungs were isolated from male New Zealand white rabbits and S-D rats and perfused with 20 μM [ 14 C] cystamine (Sp. Act., 16.4 mCi/mmol) for 60 min and 30 min, respectively. Cystamine and its metabolites in lung as well as in perfusate were separated by TLC and quantitated using scintillation spectrometry. Similar experiments were also conducted with 20 μM taurine to investigate its fate in perfused lungs. Significant pulmonary uptake of cystamine and taurine occurred during perfusion. Cystamine was metabolized to [ 14 C] hypotaurine and [ 14 C] taurine. No further metabolism of taurine was evident in rat or rabbit lungs. Inclusion of 1 nM GSH did not significantly alter the ability of lungs to sequester cystamine, but the metabolism of hypotaurine to taurine was decreased. It was evident that cystamine was metabolized to taurine by perfused lungs in the same way as in lung slices

  17. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  18. Assessment of perfusion pattern and extent of perfusion defect on dual-energy CT angiography: Correlation between the causes of pulmonary hypertension and vascular parameters

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Young [Dept. of Radiology, Chonbuk National University Medical School and Hospital, Research Institute of Clinical Medicine, Jeonju (Korea, Republic of); Seo, Joon Beom; Oh, Sang Young; Lee, Choong Wook; Lee, Sang Min [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Hwang, Hye Jeon [Dept. of Radiology, Hallym University College of Medicine, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Lee, Young Kyung [Dept. of Radiology, Seoul Medical Center, Seoul (Korea, Republic of)

    2014-04-15

    To assess perfusion patterns on a dual-energy pulmonary CT angiography (DECTA) of pulmonary hypertension (PHT) with variable causes and to assess whether the extent of perfusion defect can be used in the severity assessment of PHT. Between March 2007 and February 2011, DECTA scans of 62 consecutive patients (24 men, 38 women; mean age, 58.5 ± 17.3 [standard deviation] years; range, 19-87 years) with PHT were retrospectively included with following inclusion criteria; 1) absence of acute pulmonary thromboembolism, 2) maximal velocity of tricuspid regurgitation jet (TR Vmax) above 3 m/s on echocardiography performed within one week of the DECTA study. Perfusion patterns of iodine map were divided into normal (NL), diffuse heterogeneously decreased (DH), multifocal geographic and multiple peripheral wedging patterns. The extent of perfusion defects (PD), the diameter of main pulmonary artery (MPA) and the ratio of ascending aorta diameter/MPA (aortopulmonary ratio, APR) were measured. Pearson correlation analysis was performed between TR Vmax on echocardiography and CT imaging parameters. Common perfusion patterns of primary PHT were DH (n = 15) and NL (n = 12). The perfusion patterns of secondary PHT were variable. On the correlation analysis, in primary PHT, TR Vmax significantly correlated with PD, MPA and APR (r = 0.52, r = 0.40, r = -0.50, respectively, all p < 0.05). In secondary PHT, TR Vmax significantly correlated with PD and MPA (r = 0.38, r = 0.53, respectively, all p < 0.05). Different perfusion patterns are observed on DECTA of PHT according to the causes. PD and MPA are significantly correlated with the TR Vmax.

  19. Assessment of perfusion pattern and extent of perfusion defect on dual-energy CT angiography: Correlation between the causes of pulmonary hypertension and vascular parameters

    International Nuclear Information System (INIS)

    Kim, Eun Young; Seo, Joon Beom; Oh, Sang Young; Lee, Choong Wook; Lee, Sang Min; Hwang, Hye Jeon; Lee, Young Kyung

    2014-01-01

    To assess perfusion patterns on a dual-energy pulmonary CT angiography (DECTA) of pulmonary hypertension (PHT) with variable causes and to assess whether the extent of perfusion defect can be used in the severity assessment of PHT. Between March 2007 and February 2011, DECTA scans of 62 consecutive patients (24 men, 38 women; mean age, 58.5 ± 17.3 [standard deviation] years; range, 19-87 years) with PHT were retrospectively included with following inclusion criteria; 1) absence of acute pulmonary thromboembolism, 2) maximal velocity of tricuspid regurgitation jet (TR Vmax) above 3 m/s on echocardiography performed within one week of the DECTA study. Perfusion patterns of iodine map were divided into normal (NL), diffuse heterogeneously decreased (DH), multifocal geographic and multiple peripheral wedging patterns. The extent of perfusion defects (PD), the diameter of main pulmonary artery (MPA) and the ratio of ascending aorta diameter/MPA (aortopulmonary ratio, APR) were measured. Pearson correlation analysis was performed between TR Vmax on echocardiography and CT imaging parameters. Common perfusion patterns of primary PHT were DH (n = 15) and NL (n = 12). The perfusion patterns of secondary PHT were variable. On the correlation analysis, in primary PHT, TR Vmax significantly correlated with PD, MPA and APR (r = 0.52, r = 0.40, r = -0.50, respectively, all p < 0.05). In secondary PHT, TR Vmax significantly correlated with PD and MPA (r = 0.38, r = 0.53, respectively, all p < 0.05). Different perfusion patterns are observed on DECTA of PHT according to the causes. PD and MPA are significantly correlated with the TR Vmax.

  20. Changes in regional and overall lung function after bronchography

    International Nuclear Information System (INIS)

    Richez, M.; Ravez, P.; Godart, G.; Halloy, J.L.; Robience, Y.

    1980-01-01

    This investigation compares the effects of unilateral bronchography on classical pulmonary function paramerts (spirometry, CO transfer, flowvolume curve, and arterial blood gases)and radioisotopic measurements by means of 99 sup(m)Tc-labeled microspheres and 81 sup(m)Kr. The regional changes of ventilation and perfusion were quantified by a radioisotopic index, which was established for each zone of interest: explored lung and unexplored lung. The quantitative study of regional perfusion and ventilation reveals significant reduction of ventilation for lung bases, but not for lung apices. The radioisotopic measurements show a reduction of perfusion parallel to the reduction of ventilation. There is no significant correlation between traditional pulmonary function parameters and isotopic indices. Radioisotopy proved a sensitive tool for investigation of unilateral alterations. (orig.) [de

  1. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France); University Bordeaux Segalen, Bordeaux Cedex (France); Bullier, Eric; Riviere, Annalisa [Hopital Haut-Leveque, CHU Bordeaux, Department of Nuclear Medicine, Pessac (France); Dromer, Claire [Hopital Haut-Leveque, CHU Bordeaux, Department of Respiratory Diseases, Pessac (France); Picard, Francois [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiology, Pessac (France); Billes, Marc-Alain [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiac Surgery, Pessac (France); Corneloup, Olivier [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France)

    2014-01-15

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  2. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    International Nuclear Information System (INIS)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu; Bullier, Eric; Riviere, Annalisa; Dromer, Claire; Picard, Francois; Billes, Marc-Alain; Corneloup, Olivier

    2014-01-01

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  3. Reproducibility of Lobar Perfusion and Ventilation Quantification Using SPECT/CT Segmentation Software in Lung Cancer Patients.

    Science.gov (United States)

    Provost, Karine; Leblond, Antoine; Gauthier-Lemire, Annie; Filion, Édith; Bahig, Houda; Lord, Martin

    2017-09-01

    Planar perfusion scintigraphy with 99m Tc-labeled macroaggregated albumin is often used for pretherapy quantification of regional lung perfusion in lung cancer patients, particularly those with poor respiratory function. However, subdividing lung parenchyma into rectangular regions of interest, as done on planar images, is a poor reflection of true lobar anatomy. New tridimensional methods using SPECT and SPECT/CT have been introduced, including semiautomatic lung segmentation software. The present study evaluated inter- and intraobserver agreement on quantification using SPECT/CT software and compared the results for regional lung contribution obtained with SPECT/CT and planar scintigraphy. Methods: Thirty lung cancer patients underwent ventilation-perfusion scintigraphy with 99m Tc-macroaggregated albumin and 99m Tc-Technegas. The regional lung contribution to perfusion and ventilation was measured on both planar scintigraphy and SPECT/CT using semiautomatic lung segmentation software by 2 observers. Interobserver and intraobserver agreement for the SPECT/CT software was assessed using the intraclass correlation coefficient, Bland-Altman plots, and absolute differences in measurements. Measurements from planar and tridimensional methods were compared using the paired-sample t test and mean absolute differences. Results: Intraclass correlation coefficients were in the excellent range (above 0.9) for both interobserver and intraobserver agreement using the SPECT/CT software. Bland-Altman analyses showed very narrow limits of agreement. Absolute differences were below 2.0% in 96% of both interobserver and intraobserver measurements. There was a statistically significant difference between planar and SPECT/CT methods ( P software is highly reproducible. This tridimensional method yields statistically significant differences in measurements for right lung lobes when compared with planar scintigraphy. We recommend that SPECT/CT-based quantification be used for all lung

  4. Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eun Jung; Cho, Ihn Ho [Yeungnam University Hospital, Daegu (Korea, Republic of); Kang, Won Jun [Yonsei University Hospital, Seoul (Korea, Republic of); Kim, Seong Min [Chungnam National University Medical School and Hospital, Daejeon (Korea, Republic of); Won, Kyoung Sook [Keomyung University Dongsan Hospital, Daegu (Korea, Republic of); Lim, Seok Tae [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of); Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Lee, Byeong Il; Bom, Hee Seung [Chonnam National University Medical School and Hospital, Gwangju (Korea, Republic of)

    2009-12-15

    Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Forty-eight patients (M:F=26:22, Age: 63.3{+-}10.4 years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

  5. Morphology of bone defects in patient with unilateral cleft lip and palate. Cone beam x-ray CT evaluation

    International Nuclear Information System (INIS)

    Kyo, Iyu; Kubota, Masato; Sato, Yuki; Nakano, Haruhisa; Maki, Koutaro

    2006-01-01

    Orthodontic treatment planning of the cleft lip and palate vary according to the morphology of the alveolar bone and palatal bone. The purpose of this study is to evaluate the three-dimensional anatomy of the alveolar and palatal bone in children with complete unilateral cleft lip and palate. Thirty-three nonsyndromic consecutive patients with complete unilateral cleft lip and palate were treated by the cleft palate team at Showa University. Each patient had lip and palate surgeries at Showa University. Cone beam CT radiographs (CB MercuRay, Hitachi) were taken prior to secondary bone grafting, and were classified according to the method of Kita et al. 1997. Cone beam CT radiographs showed multiple types of alveolar and palatal bone morphology, and focused on special types described in the method of Kita et al. It was most frequently found that bone defects in the alveolar crest showed similar patterns in both buccal and palatal aspect, and the buccal bone defect in the nasal floor was larger than the palatal bone defect in the nasal floor. In 80% of the patients, the palatal bone defect showed similar patterns in both anterior and posterior aspects, and the anterior palatal bone defect was smaller than the posterior palatal bone defect. In addition, inadequate bone bridges were frequently found at the cleft site. It is suggested that patients with unilateral cleft lip and palate have various types of alveolar and palatal bone morphology, and are required to take three-dimensional radiographic X-rays prior to any orthodontic treatment. (author)

  6. Lung scans with significant perfusion defects limited to matching pleural effusions have a low probability of pulmonary embolism

    International Nuclear Information System (INIS)

    Datz, F.L.; Bedont, R.A.; Taylor, A.

    1985-01-01

    Patients with a pleural effusion on chest x-ray often undergo a lung scan to exclude pulmonary embolism (PE). According to other studies, when the scan shows a perfusion defect equal in size to a radiographic abnormality on chest x-ray, the scan should be classified as indeterminate or intermediate probability for PE. However, since those studies dealt primarily with alveolar infiltrates rather than pleural effusions, the authors undertook a retrospective study to determine the probability of PE in patients with pleural effusion and a matching perfusion defect. The authors reviewed 451 scans and x-rays of patients studied for suspected PE. Of those, 53 had moderate or large perfusion defects secondary to pleural effusion without other significant (>25% of a segment) effusion without other significant (>25% of a segment) defects on the scan. Final diagnosis was confirmed by pulmonary angiography (16), thoracentesis (40), venography (11), other radiographic and laboratory studies, and clinical course. Of the 53 patients, only 2 patients had venous thrombotic disease. One patient had PE on pulmonary angiography, the other patient had thrombophlebitis on venography. The remainder of the patients had effusions due to congestive heart failure (12), malignancy (12), infection (7), trauma (7), collegen vascular disease (7), sympathetic effusion (3) and unknown etiology (3). The authors conclude that lung scans with significant perfusion defects limited to matching pleural effusions on chest x-ray have a low probability for PE

  7. Assessment of pulmonary ventilation/perfusion ratio by dual radionuclides SPECT using 81mKr gas and 99mTc-MAA

    International Nuclear Information System (INIS)

    Sando, Yoshichika

    1994-01-01

    The accuracy and clinical availability of pulmonary ventilation/perfusion (V/Q) ratio images by 81m Kr gas and 99m Tc-MAA dual radionuclides SPECT was assessed in 10 normal volunteers and 31 patients with pulmonary diseases. After equalizing the total acquisition counts of both radionuclides, the ratio of 81m Kr/ 99m Tc count was calculated in each pixel and expressed as the functional map of V/Q. Then, the histogram of pixel numbers against V/Q ratio was drawn and the center of weight (CW) and standard deviation (SD) of the distribution were determined. The reproducibility of this method was excellent. In normal volunteers, CW was 1.07 and the SD was 0.25. The V/Q was lower in dorsal than in the ventral portion. SD was large and lobar or segmental high V/Q areas were clearly noted in the patients with pulmonary vascular diseases. In pulmonary emphysema, large low V/Q areas coexisted with patchy high V/Q areas. CW was small and SD was large in this group. There was a significant positive correlation between SD and P A-a O 2 . The author believes that the pulmonary ventilation/perfusion (V/Q) ratio images by dual radionuclides SPECT is a useful diagnostic procedure. Further, SD determined by this examination is thought to be a good parameter of uneven distribution of pulmonary ventilation and perfusion. (author)

  8. Prognostic significance of large perfusion defects on thallium-201 myocardial scintigraphy in dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Takata, Jun; Doi, Yoshinori; Chikamori, Taishiro; Yonezawa, Yoshihiro; Hamashige, Naohisa; Kuzume, Osamu; Ozawa, Toshio

    1989-01-01

    To evaluate the prognostic significance of perfusion abnormalities, particularly large defects, in dilated cardiomyopathy (DCM), we performed thallium-201 myocardial scintigraphy and 24-hour ambulatory ECG monitoring in 27 patients. The abnormal scintigraphic patterns and the presence of ventricular tachycardia (VT) were correlated with causes of death during a follow-up period of 30.0±19.4 months. Eight patients had large defects (LD), 11 had multiple small defects (MSD), and eight had no defects (NL). The patients with LD had extensive ventricular akinesis in the region of the perfusion defect, significantly elevated LVEDP (LD 20.6±7.4 mmHg, MSD 15.5±7.6 mmHg, NL 10.3±2.3 mmHg: LD vs NL; p<0.01, MSD vs NL; p<0.05), and reduced ejection fraction (LD 23.9±9.1%, MSD 32.7±7.2%, NL 40.3±7.7%: LD vs MSD; p<0.05, MSD vs NL; p<0.01). VT was detected in 11 patients; among whom three had LD, six had MSD, and two had no defects. Among seven patients who died during follow-up (five of heart failure, one sudden death, and one non-cardiac death), five had LD and two had MSD. There were no deaths among patients without defects. Among 11 patients with VT, only one died suddenly. In conclusion, large scintigraphic defects correlated well with severe LV dysfunction, and this is an important variable in predicting outcomes in DCM. (author)

  9. Studies on pulmonary ventilation-perfusion scintigraphy with Xe-133 in primary lung cancer, 1

    International Nuclear Information System (INIS)

    Oshibuchi, Masao

    1984-01-01

    Regional lung ventilation-perfusion scintigraphy by xenon gas was performed on 14 normal cases (normal group) and 86 cases of primary lung cancer (lung cancer group). The patients were measured in a sitting position using a scintillation camera. In normal group, the value of V, Q was higher in the lower lung field than in the upper lung field, the value of MTT was rather delayed in the upper lung field than in the lower lung field, proving to that lung clearance was better in the lower lung field than in the upper lung field. In lung cancer group, VQ match (pattern I, II) was 61 cases (71%) and VQ mismatch (pattern III, IV) was 25 cases (29%). The pattern II (VQ matched defect) accounted for 63% in lung cancer group. In this pattern, the region of disorder of V and Q was corresponded respectively, but disorder grade was not always accorded. The pattern III (normal V and disordered Q) was mainly seen in AH group (hilar type) and D group (lymph node swelling type). The V/Q in lung cancer group was widely distributed to the range of 0 to 5.8. The value of MTT was rather delayed in all cases of lung cancer group than in the normal group, because delayed MTT in focal lesion was markedly affected to whole lung. (author)

  10. Significance of single ventilation/perfusion mismatches in krypton-81m/technetium-99m lung scintigraphy

    International Nuclear Information System (INIS)

    Rosen, J.M.; Palestro, C.J.; Markowitz, D.; Alderson, P.O.

    1986-01-01

    The significance of a single area of ventilation/perfusion (V/P) mismatch in lung scans performed on patients suspected of pulmonary embolism (PE) was evaluated. Ten of 20 patients with this scan finding were found to have PE. An intermediate probability of PE was found with segmental (71%) or subsegmental (45%) single V/P mismatches. Seven of 16 patients with a single V/P mismatch and without a matching radiographic opacity had PE. Three of the four patients who had a V/P mismatch and a matching radiographic opacity were found to have PE. Multiview ventilation imaging with 81mKr was found to have advantages for the evaluation of single V/P mismatches. Based on the data available at this time, a single V/P mismatch suggests an intermediate probability of PE

  11. Repair of segmental bone defect using Totally Vitalized tissue engineered bone graft by a combined perfusion seeding and culture system.

    Directory of Open Access Journals (Sweden)

    Lin Wang

    Full Text Available BACKGROUND: The basic strategy to construct tissue engineered bone graft (TEBG is to combine osteoblastic cells with three dimensional (3D scaffold. Based on this strategy, we proposed the "Totally Vitalized TEBG" (TV-TEBG which was characterized by abundant and homogenously distributed cells with enhanced cell proliferation and differentiation and further investigated its biological performance in repairing segmental bone defect. METHODS: In this study, we constructed the TV-TEBG with the combination of customized flow perfusion seeding/culture system and β-tricalcium phosphate (β-TCP scaffold fabricated by Rapid Prototyping (RP technique. We systemically compared three kinds of TEBG constructed by perfusion seeding and perfusion culture (PSPC method, static seeding and perfusion culture (SSPC method, and static seeding and static culture (SSSC method for their in vitro performance and bone defect healing efficacy with a rabbit model. RESULTS: Our study has demonstrated that TEBG constructed by PSPC method exhibited better biological properties with higher daily D-glucose consumption, increased cell proliferation and differentiation, and better cell distribution, indicating the successful construction of TV-TEBG. After implanted into rabbit radius defects for 12 weeks, PSPC group exerted higher X-ray score close to autograft, much greater mechanical property evidenced by the biomechanical testing and significantly higher new bone formation as shown by histological analysis compared with the other two groups, and eventually obtained favorable healing efficacy of the segmental bone defect that was the closest to autograft transplantation. CONCLUSION: This study demonstrated the feasibility of TV-TEBG construction with combination of perfusion seeding, perfusion culture and RP technique which exerted excellent biological properties. The application of TV-TEBG may become a preferred candidate for segmental bone defect repair in orthopedic and

  12. Analysis of perfusion defects by causes other than acute pulmonary thromboembolism on contrast-enhanced dual-energy CT in consecutive 537 patients

    International Nuclear Information System (INIS)

    Kim, Bo Hyun; Seo, Joon Beom; Chae, Eun Jin; Lee, Hyun Joo; Hwang, Hye Jeon; Lim, Chaehun

    2012-01-01

    Objective: To assess causes, incidence and patterns of perfusion defects (PDs) on dual-energy perfusion CT angiography (DECTA) in clinically suspected acute pulmonary thromboembolisms (PTE). Materials and methods: Consecutive 537 patients who underwent DECTA for suspicion of PTE were retrospectively reviewed. After excluding patients with possible PTE or unsatisfactory perfusion map quality, 299 patients with 1697 lobes were included. The DECTA (Somatom Definition, Siemens) was performed at 140 kV and 80 kV. Color-coded perfusion images were obtained with a lung PBV application of the workstation software (Syngo Dual Energy). The presence, incidence, three patterns of PDs (wedge-shaped, heterogeneous, and regionally homogeneous), pulmonary diseases, and the matchedness between the PD and the disease extent were studied. Results: 315 of 1697 lobes (18.6%) in 156 of 299 patients (81.3%) showed PDs. Among them, 51 (3%), 257 (15.1%), and 7 (0.4%) lobes had PDs due to vascular, nonvascular, and unidentifiable causes, respectively. Vascular causes include: pulmonary arterial (PA) hypertension (0.7%), extrinsic occlusion of PA by fibrosis (0.6%), PA hypoplasia (0.6%), vasculitis (0.5%), cancer mass compressing PA, venous occlusion, AVM, and pulmonary angiosarcoma. Most of PDs were wedge-shaped and well-matched. Nonvascular causes include: mosaic attenuation (4.1%), emphysema (3.2%), interstitial fibrosis (1.6%), bronchitis (1.4%), GGO (1.2%), cellular bronchiolitis (1%), bronchiectasis, airway obstruction, compensaroty lung hyperinflation, air trapping, cor-pulmonale, bronchopneumonia, physiologic decreased ventilation, and segmental bronchial atresia. Most of PDs showed heterogeneous pattern and were not matched. Conclusions: Various vascular and nonvascular diseases cause PDs on DECTA. Each disease shows different pattern of PD depending on pathophysiology and physiologic compensation.

  13. Myocardial viability in cases with persistent perfusion defects on the dipyridamole thallium-201 scintigram. A comparative study with autopsy findings

    International Nuclear Information System (INIS)

    Nakayama, Masafumi; Mashima, Saburo; Ohkawa, Shin-ichiro; Tanno, Munehiko; Yamada, Hideo.

    1996-01-01

    The aim of this study was to assess the incidence of myocardial infarction among persistent perfusion defects in dipyridamole-stress thallium scintigraphy by inspecting autopsied hearts and to evaluate whether the regional thallium activity of a scintigraphic defect can predict the presence of infarction. Autopsied hearts were compared with dipyridamole myocardial scintigrams undertaken during life in 27 patients (mean age 85±8 years). The time interval from stress testing until death was 428±351 days. Regional thallium uptake of delayed perfusion defect was calculated on the short axis images. The grade of regional myocardial fibrosis in autopsy specimens was also quantified to correlate with the corresponding regional thallium uptake. In 6 of 15 (40%) regions with persistent defects on the scintigram, myocardial infarction was not found at autopsy. Regional thallium-201 uptake of delayed defects < 50% diagnosed infarction with a sensitivity of 82% and a specificity of 80%. A linear correlation (r=-0.67) was observed between percent thallium-201 uptake and the degree of myocardial fibrosis. In conclusion, perfusion defects at 4-hour imaging in dipyridamole-stress testing may overestimate the presence of myocardial infarction and regional thallium-201 activity is helpful in distinguishing between defects with and without infarction. (author)

  14. Regional distribution of ventilation-perfusion ratio in patients with interstitial pneumonia using Kr-81m

    International Nuclear Information System (INIS)

    Sekine, Hiroshi; Kawakami, Kenji; Shimada, Takao

    1983-01-01

    In order to know the pathophysiological change of interstitial pneumonia, it is important to detect the morphological change of vascular and air way systems in the lung. The study group consisted of 12 patients of interstitial pneumonia including IIP, PSS, RA, sarcoidosis, and hypersensitive pneumonia. The Kr-81m bolus inhalation from 3 different lung volumes were analyzed to detect regional ventilation abnormalities. The regional distribution of ventilation-perfusion ratio (V/Q) in the lung was obtained from the continuous inhalation and infusion Kr-81 m. In 7 patients, regional distribution of V/Q was also measured at rest and during exercise. In advanced stage of interstitial pneumonia, radioactivity in lower lung fields was decreased in bolus inhalation from TLC-400 ml lung volume, and present in lower lung in bolus inhalation from RV level. These findings are representing air way rigidity especially in lower lung fields. However, in early stage or reversible cases, it is difficult to detect the abnormal distribution of radioactivity in lung, in spite of decreased PO 2 . So it seems impossible to screen early stage or reversible cases of interstitial pneumonia by bolus inhalation method alone. At rest for normal subjects in the upright position, the apical zone had a high V/Q, but in the lower parts two third of V/Q distribution was relatively homogeneous. During exercise at 50W, the distribution became more uniform. In most cases of the disease, weak exercise (less than 40W) produced the same uniform V/Q distribution. It should be noted that in the disease not only was perfusion in upper lung fields increased, but that perfusion of lower lung fields was reduced. So late in the cource of extension of the disease, pulmonary vascular bed in the lower lung fields is restricted.(J.P.N.)

  15. ECG-manifest and ECG-silent dipyridamole technetium-99m sestamibi SPET perfusion defects in patients with ischaemic heart disease

    International Nuclear Information System (INIS)

    Galli, M.; Marcassa, C.; Bosimini, E.; Zoccarato, O.; Comazzi, F.; Giannuzzi, P.

    1997-01-01

    To investigate the relationship between ECG changes and perfusion abnormalities, body surface maps were recorded during dipyridamole infusion in 55 subjects (11 normals and 44 patients with ischaemic heart disease) undergoing dipyridamole technetium-99m sestamibi single-photon emission tomography (SPET). All had a normal resting ECG. The extent and severity of the sestamibi defect were quantified. New negative areas in the isointegral maps and rest-dipyridamole map differences >2 SD from normal limits were considered abnormal. After dipyridamole in normals, neither perfusion defects nor ≥1 mm ST segment depression on 12-lead ECG nor new negative areas in isointegral maps occurred. In patients, dipyridamole induced new perfusion defects in 35 (80%) but ST segment depression in only 18 (41%, P<0.001). Of the 35 patients with perfusion defects, 17 (49%, group 1) showed ST segment depression, while the other 18 (51%, group 2) did not. Abnormal body surface maps were found in 100% of group 1 and 88% of group 2 patients (NS). In group 1, the provoked hypoperfusion was of greater extent (P=0.007) and severity (P=0.01) and the onset of map abnormalities was significantly earlier (P<0.001) than in group 2; time to map abnormalities was also significantly shorter than time to ST segment depression (P=0.01). In the 35 patients with complete scintigraphic, body map and angiographic data, the severity of reversible perfusion defect proved to be the strongest correlate of ST segment depression upon logistic regression analysis. Thus, sestamibi SPET abnormalities after dipyridamole are almost always associated with electrical changes on body surface maps, suggesting myocardial ischaemia as their cause. The much less common 12-lead ECG changes are slower to appear and reflect a more severe hypoperfusion. (orig./MG). With 5 figs., 4 tabs

  16. Hearing thresholds and ventilation tube treatment in children with unilateral cleft lip and palate.

    Science.gov (United States)

    Tengroth, Birgitta; Hederstierna, Christina; Neovius, Erik; Flynn, Traci

    2017-06-01

    Children with cleft lip and palate have a high prevalence of otitis media with effusion (OME) which is often associated with a fluctuating, conductive hearing loss in the low and mid-frequencies and a risk for permanent hearing loss in the higher frequencies. Although common, there is no consensus on the treatment of OME with ventilation tubes. The aim of this study is to document if the risk for permanent hearing loss and acquired cholesteatoma increases due to treatment with ventilation tubes (VT treatments) during childhood in a group of children with cleft lip and palate. A retrospective medical chart review of 33 children (25 boys and 8 girls) born with unilateral cleft lip and palate (UCLP) was completed. Audiological data (results of hearing sensitivity tests, the total number of hearing tests, and number of VT treatments) were extracted from medical records from when the children were 4-7 and >7-10 years of age. The hearing thresholds in the speech frequencies improved with age (p 7-10 years of age. There were no significant correlations between number of VT treatments and hearing thresholds at >7-10 years. Four of the 33 children presented with complications: two children exhibited perforations of the ear drum (6.1%) and two children developed unilateral cholesteatoma (6.1%). In the current study, the hearing sensitivity of children with cleft lip and palate improved with age. However, this improvement was not seen in the higher frequencies. Twelve percent of the children experienced complications following VT treatments. Due to these complications, it is recommended that all children with cleft palate should have routine follow-ups by an ENT doctor and audiologist. As part of the routine follow-up care, hearing assessments should be performed before and after VT treatments. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Comparison of ventilation-perfusion single-photon emission computed tomography (V/Q SPECT) versus dual-energy CT perfusion and angiography (DECT) after 6 months of pulmonary embolism (PE) treatment

    Energy Technology Data Exchange (ETDEWEB)

    Meysman, M., E-mail: marc.meysman@uzbrussel.be [Respiratory Division, Department of Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Everaert, H., E-mail: nucgeth@gmail.com [Department of Nuclear Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Buls, N., E-mail: nico.buls@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Nieboer, K., E-mail: koenraad.nieboer@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Mey, J. de, E-mail: Johan.deMey@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium)

    2015-09-15

    Highlights: • Incomplete resolution of pulmonary emboli occurs frequently. • Residual V/Q-SPECT defects correspond in the majority of cases with defects seen on DECT. • Some (11.1%) defects on V/Q-SPECT are not present on comparable DECT images. - Abstract: Background: The natural evolution of treated symptomatic pulmonary embolism shows often incomplete resolution of pulmonary thrombi. The prevalence of perfusion defects depend on the image modality used. This study directly compares V/Q SPECT with DECT. Methods: A single-center prospective observational cohort study of patients with intermediate risk PE, reassessed at the end of treatment with V/Q SPECT. Abnormal V/Q SPECT images were compared with DECT. Results: We compared DECT en V/Q SPECT in 28 consecutive patients with persistent V/Q mismatch on V/Q SPECT, 13 men and 15 woman, mean age 60 (+17), range 23–82 year. One patient was excluded from the final analysis due to inferior quality DECT. In 18/27 (66.7%) the results were concordant between CTPA (persistent embolus visible), DECT (segmentary defects on iodine map) and V/Q SPECT (segmentary ventilation–perfusion mismatch). In 3/18 (11.1% of the total group) the partialy matched V/Q SPECT defect could be explained on DECT lung images by lung infarction. In 6/27 (22.1%) only hypoperfusion was seen on DECT iodine map. In 3/27 (11.1%) results were discordant between V/Q SPECT and DECT images. Conclusion: Six months after diagnosis of first or recurrent PE, residual pulmonary perfusion-defects encountered on V/Q-SPECT corresponds in the majority of patients with chronic thromboembolic disease seen on DECT. In 22.1% of patients V/Q SPECT mismatch only corresponds with hypoperfusion on iodine map DECT scan. Some (11.1%) of the chronic thromboembolic lesions seen on V/Q SPECT can not be explained by DECT results.

  18. Xenon ventilation-perfusion lung scans. The early diagnosis of inhalation injury

    International Nuclear Information System (INIS)

    Schall, G.L.; McDonald, H.D.; Carr, L.B.; Capozzi, A.

    1978-01-01

    The use of xenon Xe-133 ventilation-perfusion lung scans for the early diagnosis of inhalation injury was evaluated in 67 patients with acute thermal burns. Study results were interpreted as normal if there was complete pulmonary clearance of the radioactive gas by 150 seconds. Thirty-two scans were normal, 32 abnormal, and three technically inadequate. There were three true false-positive study results and one false-negative study result. Good correlation was found between the scan results and various historical, physical, and laboratory values currently used to evaluate inhalation injury. The scans appeared to be the most sensitive method for the detection of early involvement, often being abnormal several days before the chest roentgenogram. Xenon lung scanning is a safe, easy, accurate, and sensitive method for the early diagnosis of inhalation injury and has important therapeutic and prognostic implications as well

  19. MRI methods for pulmonary ventilation and perfusion imaging; Methoden der MRT zur Ventilations- und Perfusionsbildgebung der Lunge

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland); Bauman, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin - Radiologische Physik, Basel (Switzerland)

    2016-02-15

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O{sub 2}-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [German] Die separate Beurteilung von Atemmechanik, Gasaustauschprozessen und Lungenzirkulation ist wesentlich fuer die Diagnose und Therapie von Lungenerkrankungen. Klinische Lungenfunktionstests sind aufgrund ihrer zumeist nur globalen Aussage oft nicht hinreichend spezifisch in der Differenzialdiagnostik oder eingeschraenkt sensitiv bei der

  20. Optimization of Rb-82 PET acquisition and reconstruction protocols for myocardial perfusion defect detection

    Science.gov (United States)

    Tang, Jing; Rahmim, Arman; Lautamäki, Riikka; Lodge, Martin A.; Bengel, Frank M.; Tsui, Benjamin M. W.

    2009-05-01

    The purpose of this study is to optimize the dynamic Rb-82 cardiac PET acquisition and reconstruction protocols for maximum myocardial perfusion defect detection using realistic simulation data and task-based evaluation. Time activity curves (TACs) of different organs under both rest and stress conditions were extracted from dynamic Rb-82 PET images of five normal patients. Combined SimSET-GATE Monte Carlo simulation was used to generate nearly noise-free cardiac PET data from a time series of 3D NCAT phantoms with organ activities modeling different pre-scan delay times (PDTs) and total acquisition times (TATs). Poisson noise was added to the nearly noise-free projections and the OS-EM algorithm was applied to generate noisy reconstructed images. The channelized Hotelling observer (CHO) with 32× 32 spatial templates corresponding to four octave-wide frequency channels was used to evaluate the images. The area under the ROC curve (AUC) was calculated from the CHO rating data as an index for image quality in terms of myocardial perfusion defect detection. The 0.5 cycle cm-1 Butterworth post-filtering on OS-EM (with 21 subsets) reconstructed images generates the highest AUC values while those from iteration numbers 1 to 4 do not show different AUC values. The optimized PDTs for both rest and stress conditions are found to be close to the cross points of the left ventricular chamber and myocardium TACs, which may promote an individualized PDT for patient data processing and image reconstruction. Shortening the TATs for <~3 min from the clinically employed acquisition time does not affect the myocardial perfusion defect detection significantly for both rest and stress studies.

  1. Influence of perfusion and ventilation scans on therapeutic decision making and outcome in cases of possible embolism

    International Nuclear Information System (INIS)

    Mercandetti, A.J.; Kipper, M.S.; Moser, K.M.

    1985-01-01

    The authors examined the influence of perfusion (Q) and ventilation (V) scans on therapeutic decision making and outcome among 229 patients referred for lung scans because embolism was suggested and found that specific V/Q scan patterns strongly influenced postscan decisions regarding initiation, maintenance or cessation of heparin therapy. These therapeutic decisions bore a relationship to outcome (recurrences and death) and disclosed decision-making deficits that need remedy by future investigational and educational efforts. 25 references, 5 tables

  2. Abnormal perfusion on myocardial perfusion SPECT in patients with Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Kang, Do Young; Cha, Kwang Soo; Han, Seung Ho; Park, Tae Ho; Kim, Moo Hyun; Kim, Young Dae

    2005-01-01

    Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkison-White) syndrome. Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECT with Fitzpatrick's algorithm of electrophysiologic study and radiofrequency catheter ablation. Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients(mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent (11.0 ± 8.5%, range:3 ∼ 35%) and mild to moderate severity (-71 ± 42.7%, range:-217 ∼ -39%) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patients with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but if did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome

  3. Abnormal perfusion on myocardial perfusion SPECT in patients with Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Cha, Kwang Soo; Han, Seung Ho; Park, Tae Ho; Kim, Moo Hyun; Kim, Young Dae [Donga University College of Medicine, Busan (Korea, Republic of)

    2005-02-15

    Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkison-White) syndrome. Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECT with Fitzpatrick's algorithm of electrophysiologic study and radiofrequency catheter ablation. Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients(mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent (11.0 {+-} 8.5%, range:3 {approx} 35%) and mild to moderate severity (-71 {+-} 42.7%, range:-217 {approx} -39%) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patients with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but if did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome.

  4. Can preoperative myocardial perfusion scintigraphy predict changes in left ventricular perfusion and function after coronary artery bypass graft surgery?

    DEFF Research Database (Denmark)

    Eckardt, Rozy; Kjeldsen, Bo Juel; Johansen, Allan

    2012-01-01

    OBJECTIVESWe wanted to evaluate whether preoperative myocardial perfusion scintigraphy (MPS) could predict changes in cardiac symptoms and postoperative myocardial perfusion and left ventricular function after coronary artery bypass grafting (CABG).METHODSNinety-two patients with stable angina...... in 26%. Left ventricular ejection fraction (LVEF), which was normal before operation in 45%, improved in 40% of all patients. The increase in LVEF was not related to the preoperative pattern of perfusion defects. Of 30 patients with normalized perfusion after CABG, 29 (97%) had reversible defects...... that reversible or partly reversible perfusion defects at a preoperative MPS have a high chance of normalized myocardial perfusion assessed by MPS 6 months after operation. Normal perfusion is obtained almost exclusively in territories with reversible ischaemia. Symptoms improved in nearly all patients and LVEF...

  5. Clinical study of regional ventilation and perfusion of pulmonary disease by ventilatory steady state measurement with Xe-133

    Energy Technology Data Exchange (ETDEWEB)

    Nishi, Fumiaki

    1984-12-01

    Ventilatory steady state measurement with Xe-133 were performed to evaluate regional ventilation (V radical) and perfusion (Q radical) in 60 cases of primary lung cancer and 39 cases of pulmonary diseases-chronic obstructive pulmonary disease (COPD), pulmonary fibrosis, sarcoidosis, mitral stenosis with pulmonary hypertension (PH), pulmonary alveolar proteinosis, bronchial adenoma and pulmonary embolism. Of 60 cases of lung cancer, 11 cases showed V radicalQ radical mismatch (18%). Even in the V radicalQ radical matched defect cases, a different grade of disorder was seen in V radical and Q radical and the grade of Q radical was severer than the grade of V radical. Of 38 cases irradiated by Linac X-ray, 3 cases whose V radical, Q radical were disordered a little before irradiation recovered completely to normal range after irradiadiation. Of 38 cases subjected to radiation therapy, radiation injury of lung was recognized in 22 cases. In the cases of recovered V radical, Q radical after irradiation, radiation injury of lung occurred, and then V radical, Q radical disordered and returned to pre-irradiation value. In the cases that recovered little in V radical, Q radical, radiation injury of lung occurred, and then V radical, Q radical could not return to pre-irradiation value. In 39 cases of pulmonary diseases, 7 cases of sarcoidosis showed normal V radical and Q radical value. 13 cases of COPD was available to evaluate the regional pulmonary function in MTT (Mean Transit Time). V radical, Q radical were slightly disordered and MTT proloned slightly in 10 cases of diffuse pulmonary fibrosis where a marked fibrosis lesion was remarkable. Six cases of PH showed significant correlation between the left ventricular mean pressure and the perfusion ratio of upper and lower lung field. (J.P.N.).

  6. Clinical study of regional ventilation and perfusion of pulmonary disease by ventilatory steady state measurement with Xe-133

    International Nuclear Information System (INIS)

    Nishi, Fumiaki

    1984-01-01

    Ventilatory steady state measurement with Xe-133 were performed to evaluate regional ventilation (V radical) and perfusion (Q radical) in 60 cases of primary lung cancer and 39 cases of pulmonary diseases-chronic obstructive pulmonary disease (COPD), pulmonary fibrosis, sarcoidosis, mitral stenosis with pulmonary hypertension (PH), pulmonary alveolar proteinosis, bronchial adenoma and pulmonary embolism. Of 60 cases of lung cancer, 11 cases showed V radicalQ radical mismatch (18%). Even in the V radicalQ radical matched defect cases, a different grade of disorder was seen in V radical and Q radical and the grade of Q radical was severer than the grade of V radical. Of 38 cases irradiated by Linac X-ray, 3 cases whose V radical, Q radical were disordered a little before irradiation recovered completely to normal range after irradiadiation. Of 38 cases who performed the radiation therapy, radiation injury of lung was recognized in 22 cases. In the cases of recovered V radical, Q radical after irradiation, radiation injury of lung occurred, and then V radical, Q radical disordered and returned to pre-irradiation value. In the cases that recovered little in V radical, Q radical, radiation injury of lung occurred, and then V radical, Q radical could not return to pre-irradiation value. In 39 cases of pulmonary diseases, 7 cases of sarcoidosis showed normal V radical and Q radical value. 13 cases of COPD was available to evaluate the regional pulmonary function in MTT (Mean Transit Time). V radical, Q radical were slightly disordered and MTT proloned slightly in 10 cases of diffuse pulmonary fibrosis where a marked fibrosis lesion was remarkable. Six cases of PH showed significant correlation between the left ventricular mean pressure and the perfusion ratio of upper and lower lung field. (J.P.N.)

  7. Unilateral megalencephaly associated with contralateral neuronal migration defect

    International Nuclear Information System (INIS)

    Arslan, A.; Demirci, A; Ciftci, E.

    1999-01-01

    A case of unilateral megalencephaly associated with contralateral cortical dysplasia and grey matter heterotopia is reported. The corpus callosum is agenetic and the basal ganglia are dysplastic. Unilateral megalencephaly (UM) is a rare malformation characterized by unilateral enlargement of one cerebral hemisphere with ipsilateral lateral ventricle dilatation, abnormal gyral pattern and cortical thickening. Association of UM with contralateral cortical dysplasia, grey matter heterotopia and corpus callosum agenesis has not been reported in previous studies. Copyright (1999) Blackwell Science Pty Ltd

  8. Effects of perfusion detect on the measurement of left ventricular mass, ventricular volume and post-stress left ventricular ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Sun Keun; Lee, Sang Woo; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2002-01-01

    The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluated the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Forty-six patients (male/female=34:12, mean age=64 years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by autoquant program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS in patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect

  9. ST-vector orientation and location of myocardial perfusion defects during exercise

    International Nuclear Information System (INIS)

    Simoons, M.L.; Withagen, A.; Vinke, R.; Kooy, P.; Bakker, W.; Erasmus Universiteit, Rotterdam

    1978-01-01

    In 34 patients with chest pain the spatial orientation of the ST-vectors in the exercise electrocardiogramm 30 and 80 msec after the end of QRS were compared with the location of exercise induced local defects of myocardial uptake of 201 Tl. The following results were obtained: 1. The sensitivity and specifity of myocardial perfusion imaging after exercise were the same as those of exercise electrocardiograms; 2. No relation could be observed beween the location of reduced 201 Tl uptake during exercise and the spatial orientation of the ST-vectors. (orig.) [de

  10. Dynamic Chest Image Analysis: Model-Based Perfusion Analysis in Dynamic Pulmonary Imaging

    Directory of Open Access Journals (Sweden)

    Kiuru Aaro

    2003-01-01

    Full Text Available The "Dynamic Chest Image Analysis" project aims to develop model-based computer analysis and visualization methods for showing focal and general abnormalities of lung ventilation and perfusion based on a sequence of digital chest fluoroscopy frames collected with the dynamic pulmonary imaging technique. We have proposed and evaluated a multiresolutional method with an explicit ventilation model for ventilation analysis. This paper presents a new model-based method for pulmonary perfusion analysis. According to perfusion properties, we first devise a novel mathematical function to form a perfusion model. A simple yet accurate approach is further introduced to extract cardiac systolic and diastolic phases from the heart, so that this cardiac information may be utilized to accelerate the perfusion analysis and improve its sensitivity in detecting pulmonary perfusion abnormalities. This makes perfusion analysis not only fast but also robust in computation; consequently, perfusion analysis becomes computationally feasible without using contrast media. Our clinical case studies with 52 patients show that this technique is effective for pulmonary embolism even without using contrast media, demonstrating consistent correlations with computed tomography (CT and nuclear medicine (NM studies. This fluoroscopical examination takes only about 2 seconds for perfusion study with only low radiation dose to patient, involving no preparation, no radioactive isotopes, and no contrast media.

  11. Effects of isoproterenol on distribution of perfusion in embolized dog lungs

    International Nuclear Information System (INIS)

    Shepard, J.W. Jr.; Hauer, D.; Sgroi, V.; Moser, K.M.

    1979-01-01

    In 19 mechanically ventilated, anesthetized dogs, autologous venous thrombi were formed in the inferior vena cava and subsequently released. Serial perfusion lung scintigrams revealed the postembolic distribution of pulmonary blood flow before, during, and after the infusion of isoproterenol at 2.2 μg/min. Isoproterenol failed to restore perfusion to embolically occluded regions. When reperfusion occurred it was attributable to clot resolution. Gas exchange and hemodynamic measurements obtained in seven thromboembolized animals showed no scan evidence of reperfusion during the isoproterenol infusion. After embolization, cardiac output increased from 1.7 to 2.6 liter/min (p 2 from 38.0 to 45.3 mm Hg (p 2 to 50.7 mm Hg, along with a decrease in pulmonary vascular resistance from the postembolic mean of 448 to 246 dynes.sec.cm -5 (p < 0.05). Perfusion defects following acute pulmonary thromboembolization are not altered by the infusion of the potent pulmonary vasodilator, isoproterenol. Infusion of this drug following thromboembolization may have potential therapeutic benefit by reducing pulmonary vascular resistance, increasing cardiac output, and elevating the mixed-venous oxygen tension

  12. Herpes simplex encephalitis: increased retention of Tc-99m HMPAO on acetazolamide enhanced brain perfusion SPECT

    International Nuclear Information System (INIS)

    Choi, Yun Young; Kim, Kwon Hyung; Kim, Seung Hyun; Cho, Suk Shin

    1998-01-01

    We present an interesting case of herpes simplex encephalitis, which showed increased upta unilateral temporal cortex on brain perfusion SPECT using Tc-99m HMPAO, but in bilateral tem cortex after acetazolamide administration. A 42-year-old man was admitted via emergency room, due to rapidly progressing hea disorientation and mental changes. On neurologic examination, neck stiffness and Kernig sign noted. CSF examination showed pleocytosis with lymphcyte predominance. MRI showed swelling bilateral temporal lobe with left predominance, suggestive of herpes simplex encephalitis. Baseline/ Acetazolamide brain perfusion SPECT were acquired consecutively at the same position IV administration of 740MBq and additional 1480 MBq of Tc-99m HMPAO respectively. The temporal and inferior frontal cortex showed markedly increased perfusion on the baseline acetazolamide-enhanced SPECT images. The right temporal cortex showed normal uptake on the b SPECT images, and markedly increased uptake after acetazolamide administration, which seemed to the abundant vascularity at the acute inflammation site without marked brain damage. The fo brain perfusion SPECT after 6 months showed perfusion defect in left temporal cortex but norm perfusion in right temporal cortex. Therefore, we can conclude that baseline SPECT is helpful for the prediction of the prognosis acetazolamide SPECT for the evaluation of the extent of herpes simples encephalitis

  13. High-resolution pulmonary ventilation and perfusion PET/CT allows for functionally adapted intensity modulated radiotherapy in lung cancer

    International Nuclear Information System (INIS)

    Siva, Shankar; Thomas, Roshini; Callahan, Jason; Hardcastle, Nicholas; Pham, Daniel; Kron, Tomas; Hicks, Rodney J.; MacManus, Michael P.; Ball, David L.; Hofman, Michael S.

    2015-01-01

    Background and purpose: To assess the utility of functional lung avoidance using IMRT informed by four-dimensional (4D) ventilation/perfusion (V/Q) PET/CT. Materials and methods: In a prospective clinical trial, patients with non-small cell lung cancer (NSCLC) underwent 4D-V/Q PET/CT scanning before 60 Gy of definitive chemoradiation. Both “highly perfused” (HPLung) and “highly ventilated” (HVLung) lung volumes were delineated using a 70th centile SUV threshold, and a “ventilated lung volume” (VLung) was created using a 50th centile SUV threshold. For each patient four IMRT plans were created, optimised to the anatomical lung, HPLung, HVLung and VLung volumes, respectively. Improvements in functional dose volumetrics when optimising to functional volumes were assessed using mean lung dose (MLD), V5, V10, V20, V30, V40, V50 and V60 parameters. Results: The study cohort consisted of 20 patients with 80 IMRT plans. Plans optimised to HPLung resulted in a significant reduction of functional MLD by a mean of 13.0% (1.7 Gy), p = 0.02. Functional V5, V10 and V20 were improved by 13.2%, 7.3% and 3.8% respectively (p-values < 0.04). There was no significant sparing of dose to functional lung when adapting to VLung or HVLung. Plan quality was highly consistent with a mean PTV D95 and D5 ranging from 60.8 Gy to 61.0 Gy and 63.4 Gy to 64.5 Gy, respectively, and mean conformity and heterogeneity index ranging from 1.11 to 1.17 and 0.94 to 0.95, respectively. Conclusion: IMRT plans adapted to perfused but not ventilated lung on 4D-V/Q PET/CT allowed for reduced dose to functional lung whilst maintaining consistent plan quality

  14. Impact of patient-specific factors, irradiated left ventricular volume, and treatment set-up errors on the development of myocardial perfusion defects after radiation therapy for left-sided breast cancer

    International Nuclear Information System (INIS)

    Evans, Elizabeth S.; Prosnitz, Robert G.; Yu Xiaoli; Zhou Sumin; Hollis, Donna R.; Wong, Terence Z.; Light, Kim L.; Hardenbergh, Patricia H.; Blazing, Michael A.; Marks, Lawrence B.

    2006-01-01

    Purpose: The aim of this study was to assess the impact of patient-specific factors, left ventricle (LV) volume, and treatment set-up errors on the rate of perfusion defects 6 to 60 months post-radiation therapy (RT) in patients receiving tangential RT for left-sided breast cancer. Methods and Materials: Between 1998 and 2005, a total of 153 patients were enrolled onto an institutional review board-approved prospective study and had pre- and serial post-RT (6-60 months) cardiac perfusion scans to assess for perfusion defects. Of the patients, 108 had normal pre-RT perfusion scans and available follow-up data. The impact of patient-specific factors on the rate of perfusion defects was assessed at various time points using univariate and multivariate analysis. The impact of set-up errors on the rate of perfusion defects was also analyzed using a one-tailed Fisher's Exact test. Results: Consistent with our prior results, the volume of LV in the RT field was the most significant predictor of perfusion defects on both univariate (p = 0.0005 to 0.0058) and multivariate analysis (p = 0.0026 to 0.0029). Body mass index (BMI) was the only significant patient-specific factor on both univariate (p = 0.0005 to 0.022) and multivariate analysis (p = 0.0091 to 0.05). In patients with very small volumes of LV in the planned RT fields, the rate of perfusion defects was significantly higher when the fields set-up 'too deep' (83% vs. 30%, p = 0.059). The frequency of deep set-up errors was significantly higher among patients with BMI ≥25 kg/m 2 compared with patients of normal weight (47% vs. 28%, p = 0.068). Conclusions: BMI ≥25 kg/m 2 may be a significant risk factor for cardiac toxicity after RT for left-sided breast cancer, possibly because of more frequent deep set-up errors resulting in the inclusion of additional heart in the RT fields. Further study is necessary to better understand the impact of patient-specific factors and set-up errors on the development of RT

  15. Diagnostic significance of lung ventilation study with sup(81m)Kr gas

    International Nuclear Information System (INIS)

    Narabayashi, Isamu; Ito, Yasuhiko; Ohtsuka, Nobuaki; Muranaka, Akira; Yokobayashi, Tsuneo

    1979-01-01

    Lung ventilation study was performed on 43 patients by the continuous inhalation of sup(81m)Kr gas from a 81 Rb-sup(81m)Kr generator (Nihon Mediphysics Inc. Hyogo Japan). The patients were measured in a sitting position using a scintillation camera in conjunction with a data processor. In 37 cases, scintigraphic findings were compared with those of sup(99m)Tc-MAA images. We discussed the ventilation/perfusion mismatching cases, especially in those of the pulmonary arterial abnormarity and lung cancer. In some of the discrepancy between ventilation and perfusion, nuclear angiography with sup(99m)Tc-HSA was performed. The following results were obtained by those studies. 1) The distribution of sup(81m)Kr gas within the lung is considered proportional to regional ventilation because of a short half life of sup(81m)Kr (13 seconds). 2) The ventilation image with sup(81m)Kr gas was clearly visualized because of the lower gamma-ray energy and much accumulation of activity. 3) Combined use of ventilation-perfusion scintigraphy and nuclear angiography often gave us new additional informations about the pathophysiological condition of lung. 4) In mismatching cases of lung cancer, perfusion was usually more impaired than ventilation. (author)

  16. Correlation of cerebrovascular reserve as measured by acetazolamide-challenged perfusion CT with collateral circulation in unilateral high grade carotid stenosis

    International Nuclear Information System (INIS)

    Hong, Doran; Lee, Young Hen; Seo, Hyung Suk; Je, Bo Kyoung; Suh, Sang Il; Seol, Hae Young; Kim, Jung Hyuk; Lee, Nam Joon; Yang, Kyung Sook

    2014-01-01

    We correlated cerebrovascular reserve in unilateral high grade carotid artery stenosis or occlusion with a type of collateral circulation using acetazolamide-challenged perfusion CT (ACZ-PCT). Among the patients who underwent ACZ-PCT in our institution, we retrospectively selected the patients with unilateral high grade internal carotid artery or middle cerebral artery stenosis (> 70%) or occlusion; we verified the types of their dominant collateral circulation by digital subtraction angiography or 3T MR-angiography; first, the primary collaterals flow through the circle of Willis; second, the secondary collaterals that flow through the opthalmic artery, the basal artery or other external carotid artery. Using ACZ-PCT, we measured the difference in percentage change of cerebral blood flow of the stenotic hemisphere against contralateral normal hemisphere and compared cerebrovascular reserves of lesional hemisphere, according to the type of collaterals. A total of 28 patients were included. The percentage changes of cerebral blood flow were significantly lower in the stenotic hemisphere than the contralateral hemisphere (14.34 ± 36.43% and 34.53 ± 47.82%, p < 0.001), and in the hemisphere predominantly supplied by secondary collaterals than primary (7.03 ± 32.71% and 24.37 ± 42.03%, p < 0.05), respectively. Cerebrovascular reserves in the ipsilateral hemisphere predominantly supplied by secondary collaterals were more impaired than primary collaterals in patients with unilateral high grade carotid stenosis or occlusion.

  17. Role of ventilation scintigraphy in diagnosis of acute pulmonary embolism: an evaluation using artificial neural networks

    International Nuclear Information System (INIS)

    Evander, Eva; Holst, Holger; Jaerund, Andreas; Wollmer, Per; Edenbrandt, Lars; Ohlsson, Mattias; Aastroem, Karl

    2003-01-01

    The purpose of this study was to assess the value of the ventilation study in the diagnosis of acute pulmonary embolism using a new automated method. Either perfusion scintigrams alone or two different combinations of ventilation/perfusion scintigrams were used as the only source of information regarding pulmonary embolism. A completely automated method based on computerised image processing and artificial neural networks was used for the interpretation. Three artificial neural networks were trained for the diagnosis of pulmonary embolism. Each network was trained with 18 automatically obtained features. Three different sets of features originating from three sets of scintigrams were used. One network was trained using features obtained from each set of perfusion scintigrams, including six projections. The second network was trained using features from each set of (joint) ventilation and perfusion studies in six projections. A third network was trained using features from the perfusion study in six projections combined with a single ventilation image from the posterior view. A total of 1,087 scintigrams from patients with suspected pulmonary embolism were used for network training. The test group consisted of 102 patients who had undergone both scintigraphy and pulmonary angiography. Performances in the test group were measured as area under the receiver operation characteristic curve. The performance of the neural network in interpreting perfusion scintigrams alone was 0.79 (95% confidence limits 0.71-0.86). When one ventilation image (posterior view) was added to the perfusion study, the performance was 0.84 (0.77-0.90). This increase was statistically significant (P=0.022). The performance increased to 0.87 (0.81-0.93) when all perfusion and ventilation images were used, and the increase in performance from 0.79 to 0.87 was also statistically significant (P=0.016). The automated method presented here for the interpretation of lung scintigrams shows a significant

  18. Quantitative lung perfusion evaluation using Fourier decomposition perfusion MRI.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Fischer, Andre; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2014-08-01

    To quantitatively evaluate lung perfusion using Fourier decomposition perfusion MRI. The Fourier decomposition (FD) method is a noninvasive method for assessing ventilation- and perfusion-related information in the lungs, where the perfusion maps in particular have shown promise for clinical use. However, the perfusion maps are nonquantitative and dimensionless, making follow-ups and direct comparisons between patients difficult. We present an approach to obtain physically meaningful and quantifiable perfusion maps using the FD method. The standard FD perfusion images are quantified by comparing the partially blood-filled pixels in the lung parenchyma with the fully blood-filled pixels in the aorta. The percentage of blood in a pixel is then combined with the temporal information, yielding quantitative blood flow values. The values of 10 healthy volunteers are compared with SEEPAGE measurements which have shown high consistency with dynamic contrast enhanced-MRI. All pulmonary blood flow (PBF) values are within the expected range. The two methods are in good agreement (mean difference = 0.2 mL/min/100 mL, mean absolute difference = 11 mL/min/100 mL, mean PBF-FD = 150 mL/min/100 mL, mean PBF-SEEPAGE = 151 mL/min/100 mL). The Bland-Altman plot shows a good spread of values, indicating no systematic bias between the methods. Quantitative lung perfusion can be obtained using the Fourier Decomposition method combined with a small amount of postprocessing. Copyright © 2013 Wiley Periodicals, Inc.

  19. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  20. Current concepts of protective ventilation during general anaesthesia

    NARCIS (Netherlands)

    Serpa Neto, Ary; Schultz, Marcus J.; Slutsky, Arthur S.

    2015-01-01

    Mechanical ventilation with high tidal volumes (VT) has been common practice in operating theatres because this strategy recruits collapsed lung tissue and improves ventilation-perfusion mismatch, thus decreasing the need for high inspired oxygen concentrations. Positive end-expiratory pressure

  1. Perfusion lung scanning: differentiation of primary from thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Lisbona, R.; Kreisman, H.; Novales-Diaz, J.; Derbekyan, V.

    1985-01-01

    Of eight patients with pulmonary arterial hypertension, final diagnosis established by autopsy or angiography, four had primary hypertension and four hypertension from thromboembolism. The perfusion lung scan was distinctly different in the two groups. The lung scan in primary pulmonary hypertension was associated with nonsegmental, patchy defects of perfusion, while in thromboembolic hypertensives it was characterized by segmental and/or lobar defects of perfusion with or without subsegmental defects. The perfusion lung scan is a valuable, noninvasive study in the evaluation of the patient with pulmonary hypertension of undetermined cause and in the exclusion of occult large-vessel pulmonary thromboembolism

  2. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    International Nuclear Information System (INIS)

    Sinnatamby, R.; Antoun, N.A.; Freer, C.E.L.; Miles, K.A.; Hodges, J.R.

    1996-01-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using 99m Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  3. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sinnatamby, R. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Antoun, N.A. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Freer, C.E.L. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Miles, K.A. [Dept. of Nuclear Medicine, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Hodges, J.R. [Dept. of Neurology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom)

    1996-04-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using {sup 99m}Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  4. Perfusion vector - a new method to quantify myocardial perfusion scintigraphy images: a simulation study with validation in patients

    DEFF Research Database (Denmark)

    Minarik, David; Senneby, Martin; Wollmer, Per

    2015-01-01

    Background The interpretation of myocardial perfusion scintigraphy (MPS) largely relies on visual assessment by the physician of the localization and extent of a perfusion defect. The aim of this study was to introduce the concept of the perfusion vector as a new objective quantitative method...

  5. Applying the J-optimal channelized quadratic observer to SPECT myocardial perfusion defect detection

    Science.gov (United States)

    Kupinski, Meredith K.; Clarkson, Eric; Ghaly, Michael; Frey, Eric C.

    2016-03-01

    To evaluate performance on a perfusion defect detection task from 540 image pairs of myocardial perfusion SPECT image data we apply the J-optimal channelized quadratic observer (J-CQO). We compare AUC values of the linear Hotelling observer and J-CQO when the defect location is fixed and when it occurs in one of two locations. As expected, when the location is fixed a single channels maximizes AUC; location variability requires multiple channels to maximize the AUC. The AUC is estimated from both the projection data and reconstructed images. J-CQO is quadratic since it uses the first- and second- order statistics of the image data from both classes. The linear data reduction by the channels is described by an L x M channel matrix and in prior work we introduced an iterative gradient-based method for calculating the channel matrix. The dimensionality reduction from M measurements to L channels yields better estimates of these sample statistics from smaller sample sizes, and since the channelized covariance matrix is L x L instead of M x M, the matrix inverse is easier to compute. The novelty of our approach is the use of Jeffrey's divergence (J) as the figure of merit (FOM) for optimizing the channel matrix. We previously showed that the J-optimal channels are also the optimum channels for the AUC and the Bhattacharyya distance when the channel outputs are Gaussian distributed with equal means. This work evaluates the use of J as a surrogate FOM (SFOM) for AUC when these statistical conditions are not satisfied.

  6. The Use of Unilateral Pericranial Flaps for the Closure of Difficult Medial Orbital and Upper Lateral Nasal Defects.

    Science.gov (United States)

    Newman, Jason; Costantino, Peter; Moche, Jason

    2003-11-01

    We present 3 cases in which a unilateral pericranial flap was used to repair defects in the medial orbital and upper lateral nasal areas. All three patients had undergone previous excision of malignant tumors from the upper septum and ethmoid areas. Postoperatively, they all received radiation and then developed wound breakdown with fistula formation, particularly in the area of the incisional site. All 3 patients had undergone previous unsuccessful repair of the fistula. Closure of such fistulas requires well-vascularized nonradiated tissue, which can be provided by a unilateral pericranial flap. This flap is flexible, thin, and well suited to the sinonasal area. Use of this flap avoids the need for a paramedian forehead or other musculocutaneous flap. Cosmetic results were excellent, and there have been no flap breakdowns or complications to date.

  7. Clinical value and severity of myocardial perfusion defects in asymptomatic diabetic patients with negative or weakly positive exercise treadmill test

    International Nuclear Information System (INIS)

    Zakavi, Seyed Rasoul; Taherpour, Mehdi; Moossavi, Zohreh; Sadeghi, Ramin; Kakhki, Vahidreza Dabbagh; Rokni, Haleh

    2013-01-01

    Although coronary artery disease (CAD) is the leading cause of death in type 2 diabetic patients, it is frequently asymptomatic. Myocardial perfusion imaging (MPI) is reported to show ischemia in a significant number of asymptomatic diabetic patients. We studied the prevalence and severity of myocardial perfusion defects in asymptomatic diabetic patients and its clinical impact. One hundred thirty consecutive asymptomatic patients, aged 35-65 years with type 2 diabetes mellitus and with no history of CAD and no cardiac symptoms were recruited in the study. Echocardiography, electrocardiography (ECG), routine laboratory tests and exercise treadmill test (ETT) were performed and patients with weakly positive or negative ETT underwent Dipyridamole MPI. Patients with positive ETT were referred to coronary angiography. Patients were followed for at least 17 months (mean 21.7 months) and any cardiac event was recorded. We studied 81 female and 49 male patients with mean age of 51.8 years. Negative, weakly positive and positive ETT result was noted in 74.3%, 15% and 10.7% respectively. 75% of patients with positive ETT had coronary artery disease in angiography. Gated myocardial perfusion SPECT was done in 106 patients. MPI showed reversible defect in 26.9% of the patients with a mean summed stress score of 3.3±1.8. Follow up completed in 112 patients and only one patient with abnormal MPI underwent coronary angiography followed by PTCA. No cardiac death, MI, UA or hospital admission occurred among our patients during follow up (17-26 months). Mean stress end diastolic volume (EDV) was significantly higher in patients with reversible defect compared to patients without reversible defect based on MPI findings (62.0±31.6 Vs 48.5±18.4 ml, P=0.04). Blood glucose and HbA1c were significantly higher in patients with ischemia compared to patients without ischemia (P<0.05). Meanwhile the ratio of TG to HDL was 6.06±3.2 in ischemic patients compared to 4.8±2.3 in normal

  8. Is there any advantage to the acquisition of 24-hour thallium images, in the presence of persistent perfusion defects at 4 h after reinjection?

    International Nuclear Information System (INIS)

    Bobba, K.; Botvinick, E.H.; Sciammarella, M.G.; Starsken, N.F.; Zhu, Y.Y.; Lapidus, A.; Dae, M.W.

    1998-01-01

    We determined the incidence of delayed 24-h reversibility post thallium-201 reinjection and imaging at 4 h, as well as the prognostic and significance of such delayed reversibility. We studied 46 consecutive patients with persistent thallium-201 perfusion or incompletely reversible SPET perfusion defects acquired within 10 min after reinjection performed 4 h after stress. In 38 of 46 patients 24-h images showed no further reversibility beyond the post-reinjection 4-h study (group A). Eight of 46 patients demonstrated reversibility on 24-h imaging (group B). Of these eight, three patients showed no improvement compared with the post-stress images, with a mean perfusion score of the abnormal segments of 1.25±0.50 on the 4-h images, and of 3.00 on the 24-h images. Four patients presented with nine mixed regions. Four of these regions showed an improvement in the mean perfusion score of 2.50±0.58 on 4- and 24-h images. Two of them, with moderate/severe defects, demonstrated complete reversibility at 4-h post-reinjection imaging. In addition, five other regions presented no improvement at 4-h imaging, but showed an improvement in the mean perfusion score from 0.80±0.84 at 4-h to 3.30±0.89 at 24-h imaging. Two of these regions in one patient showed a severe perfusion score of 0 at 4 h, and complete reversibility at 24 hours. Another patient had three severe perfusion defects; two of them redistributed partially at 4 h and completely at 24 h. The remaining segment with a perfusion score of 0 at 4 h, presented complete reversibility at 24 h. Two patients revealed significant reversibility at 24 h in a region that was severely underperfused after post-reinjection imaging at 4 h. Among group B patients, 75% had recent acute ischemic syndrome, compared with only 13% in group A. Among 11 patients with unstable angina, six had evidence of delayed 24-h reversibility, compared with 2 of 35 patients without clinically acute ischemia. On follow-up, there were seven cardiac

  9. Is there any advantage to the acquisition of 24-hour thallium images, in the presence of persistent perfusion defects at 4 h after reinjection?

    Energy Technology Data Exchange (ETDEWEB)

    Bobba, K.; Botvinick, E.H.; Sciammarella, M.G.; Starsken, N.F.; Zhu, Y.Y.; Lapidus, A.; Dae, M.W. [Nuclear Medicine Section, Department of Radiology, Cardiovascular Division, Department of Medicine, and the Cardiovascular Research Institute, University of California, San Francisco (United States)

    1998-05-01

    We determined the incidence of delayed 24-h reversibility post thallium-201 reinjection and imaging at 4 h, as well as the prognostic and significance of such delayed reversibility. We studied 46 consecutive patients with persistent thallium-201 perfusion or incompletely reversible SPET perfusion defects acquired within 10 min after reinjection performed 4 h after stress. In 38 of 46 patients 24-h images showed no further reversibility beyond the post-reinjection 4-h study (group A). Eight of 46 patients demonstrated reversibility on 24-h imaging (group B). Of these eight, three patients showed no improvement compared with the post-stress images, with a mean perfusion score of the abnormal segments of 1.25{+-}0.50 on the 4-h images, and of 3.00 on the 24-h images. Four patients presented with nine mixed regions. Four of these regions showed an improvement in the mean perfusion score of 2.50{+-}0.58 on 4- and 24-h images. Two of them, with moderate/severe defects, demonstrated complete reversibility at 4-h post-reinjection imaging. In addition, five other regions presented no improvement at 4-h imaging, but showed an improvement in the mean perfusion score from 0.80{+-}0.84 at 4-h to 3.30{+-}0.89 at 24-h imaging. Two of these regions in one patient showed a severe perfusion score of 0 at 4 h, and complete reversibility at 24 hours. Another patient had three severe perfusion defects; two of them redistributed partially at 4 h and completely at 24 h. The remaining segment with a perfusion score of 0 at 4 h, presented complete reversibility at 24 h. Two patients revealed significant reversibility at 24 h in a region that was severely underperfused after post-reinjection imaging at 4 h. Among group B patients, 75% had recent acute ischemic syndrome, compared with only 13% in group A. Among 11 patients with unstable angina, six had evidence of delayed 24-h reversibility, compared with 2 of 35 patients without clinically acute ischemia. On follow-up, there were seven

  10. Correlation of the perfusion scintigram with pulmonary functions in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Kou; Ashitaka, Tsuyoshi; Uchibori, Shigeyasu [Toho Univ., Tokyo (Japan). School of Medicine; Takano, Masaaki

    1992-11-01

    The authors carried out ventilation-perfusion scintigraphy and pulmonary function tests in 21 patients with chronic obstructive pulmonary disease. It was used [sup 99m]Tc-macroaggregate for perfusion scintigram and [sup 133]Xe gas for ventilation scintigram. It was added the radioactivities of rebreathing phase and made lung volume image using a computer. Regions of interest (ROIs) were derived from radioactivities in each image. ROIs on lung volume image included each whole lung and those on perfusion image included the areas which had relatively high radioactivity. The authors counted the area of ROIs on lung volume (L) and perfusion (P) images. Then it was used the ratio of perfusion to lung volume (P/L) as a parameter of pulmonary perfusion. P/L had the significant correlations with the vital capacity, the actual FFV[sub 1.0], arterial oxygen partial pressure, diffusing capacity, RV/TLC and peak flow rate. These results suggested that P/L was a useful parameter of pulmonary perfusion in chronic obstructive pulmonary disease. (author).

  11. A new positive pressure ventilation delivery system: its impact on lung ventilation studies that are technically inadequate or non diagnostic

    International Nuclear Information System (INIS)

    Bui, C.; Leiper, C.; Lee, K.; Saunders, C.; Dixson, H.; Elison, B.; Bennett, G.; Gibian, T.; Rutland, J.; Tse, V.; Elzein, H.; Babicheva, R.

    2000-01-01

    Full text: The objective of this study was to evaluate the efficacy and safety of an improved Positive Pressure Ventilation Delivery System (PVDS) in the investigation of Pulmonary Embolism (PE). The major component of PVDS is a commercially available, self-inflating 1.6L Hudson Resuscitator Bag, filled with either oxygen or air (if the patient has CO 2 retention), which is squeezed by the operator to push Technegas from the Technegas Generator Chamber to the patient via the Patient Administration Set synchronously with patient inspiration. 27 spontaneously breathing in-patients (12 males, 15 females, age range 64-89, 21 with chronic airflow limitation), whose conventional lung ventilation images were technically inadequate or non diagnostic, were re-scanned using PVDS within four days after the conventional ventilation study. Randomised blinded visual interpretation of conventional ventilation/perfusion scan vs. PVDS-assisted ventilation/perfusion scan was performed by consensus reading with two experienced observers. In conclusion PVDS was safe and well tolerated. PVDS improved the image quality of the lung ventilation scans in this cohort of patients. This technique has the potential to improve the accuracy of lung scanning in patients with severe lung disease. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  12. Hypercapnic acidosis modulates inflammation, lung mechanics, and edema in the isolated perfused lung.

    Science.gov (United States)

    De Smet, Hilde R; Bersten, Andrew D; Barr, Heather A; Doyle, Ian R

    2007-12-01

    Low tidal volume (V(T)) ventilation strategies may be associated with permissive hypercapnia, which has been shown by ex vivo and in vivo studies to have protective effects. We hypothesized that hypercapnic acidosis may be synergistic with low V(T) ventilation; therefore, we studied the effects of hypercapnia and V(T) on unstimulated and lipopolysaccharide-stimulated isolated perfused lungs. Isolated perfused rat lungs were ventilated for 2 hours with low (7 mL/kg) or moderately high (20 mL/kg) V(T) and 5% or 20% CO(2), with lipopolysaccharide or saline added to the perfusate. Hypercapnia resulted in reduced pulmonary edema, lung stiffness, tumor necrosis factor alpha (TNF-alpha) and interleukin 6 (IL-6) in the lavage and perfusate. The moderately high V(T) did not cause lung injury but increased lavage IL-6 and perfusate IL-6 as well as TNF-alpha. Pulmonary edema and respiratory mechanics improved, possibly as a result of a stretch-induced increase in surfactant turnover. Lipopolysaccharide did not induce significant lung injury. We conclude that hypercapnia exerts a protective effect by modulating inflammation, lung mechanics, and edema. The moderately high V(T) used in this study stimulated inflammation but paradoxically improved edema and lung mechanics with an associated increase in surfactant release.

  13. Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Jensen, Claus Verner

    2009-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have...... high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare...

  14. Regional ventilation in infancy. Reversal of adult pattern

    International Nuclear Information System (INIS)

    Davies, H.; Kitchman, R.; Gordon, I.; Helms, P.

    1985-01-01

    There is evidence that in infants with unilateral lung disease, oxygenation improves when the good lung is uppermost--the reverse of the situation in adults. We performed krypton-81m ventilation scanning in 18 infants and very young children (11 days to 27 months old) with and without abnormal chest radiographs. Scanning was performed with the subject supine, in the left decubitus posture (right lung uppermost), and in the right decubitus posture (right lung dependent). Fractional ventilation to the right lung fell when that lung was dependent and rose when it was uppermost (P less than 0.001). This pattern was seen regardless of the appearance of the chest radiograph. The distribution of ventilation away from dependent lung regions represents a reversal of the adult pattern, which may be due to differences between infants and adults in lung mechanics and diaphragmatic function. This study adds further weight to the argument that infants and very young children with unilateral lung disease should be positioned with their normal lung uppermost to optimize gas exchange. It also offers a rational explanation for the observation that infants with unilateral gas trapping can be successfully treated by placing them so that the diseased lung is dependent

  15. Detection of myocardial stunning with gated SPECT and its relationship with location, extension and severity of perfusion defects induced by exercise or pharmacologic stress

    International Nuclear Information System (INIS)

    Mut, F.; Beretta, M.; Vidal, I.; Rener, A.; Alonso, O.

    2002-01-01

    Aim: To investigate the relationship between transient ventricular dysfunction detected by gated SPECT with the location, extension and severity of ischemic areas in patients with reversible perfusion defects. Material and Methods: We retrospectively studied 83 patients (61±11 yrs., 61 men, 27 with previous MI) submitted for coronary artery disease (CAD) evaluation with 99mTc-MIBI gated SPECT using a 2-day protocol whose perfusion imaging pattern had been reported positive for myocardial ischemia. Stress test was exercise in 54 cases, dipyridamole in 28 and dobutamine in 1. Previous work from our group demonstrated up to 12% change in LVEF from rest to post-stress in a population with low likelihood of CAD and a normal perfusion pattern. Thus, according to % variation of left ventricular ejection fraction (LVEF) from rest to post-stress we further divided the population into 2 subgroups, (A) with less than 12% change in LVEF (n=56) and (B) with more than 12% negative variation (n=27). For evaluation of perfusion, a simplified 7-segment division of the myocardium was used and a combined ischemic score was obtained by multiplying the number of segments with reversible defects by the 1-4 assigned severity score. Results: There was no significant difference between the two groups regarding age, gender, stress result (clinical or ECG), number of fixed perfusion defects or rest LVEF. Dipyridamole test was more frequent among patients of group B. Post-stress LVEF was 49±14% for group A and 41±15% for group B, p=0.0125. Combined ischemic score was 6.82±6.5 vs. 11.96±12 respectively, p=0.014. In patients of group A, defects corresponding to the right coronary territory were more frequent, while the left descending artery territory was more commonly affected in group B patients, however this was not statistically significant. Left circumflex territory was equally affected in both groups. Conclusion: Transient ventricular dysfunction after a stress test can be

  16. Exhaled CO2 Parameters as a Tool to Assess Ventilation-Perfusion Mismatching during Neonatal Resuscitation in a Swine Model of Neonatal Asphyxia

    OpenAIRE

    Li, Elliott Shang-shun; Cheung, Po-Yin; O'Reilly, Megan; LaBossiere, Joseph; Lee, Tze-Fun; Cowan, Shaun; Bigam, David L.; Schm?lzer, Georg Marcus

    2016-01-01

    Background End-tidal CO2 (ETCO2), partial pressure of exhaled CO2 (PECO2), and volume of expired CO2 (VCO2) can be continuously monitored non-invasively to reflect pulmonary ventilation and perfusion status. Although ETCO2 ?14mmHg has been shown to be associated with return of an adequate heart rate in neonatal resuscitation and quantifying the PECO2 has the potential to serve as an indicator of resuscitation quality, there is little information regarding capnometric measurement of PECO2 and ...

  17. Assessment of the relationship between morphological emphysema phenotype and corresponding pulmonary perfusion pattern on a segmental level

    International Nuclear Information System (INIS)

    Bryant, Mark; Kauczor, Hans-Ulrich; Ley, Sebastian; Eberhardt, Ralf; Herth, Felix; Menezes, Ravi; Sedlaczek, Oliver; Ley-Zaporozhan, Julia

    2015-01-01

    Distinct morphological emphysema phenotypes were assessed by CT to show characteristic perfusion defect patterns. Forty-one patients with severe emphysema (GOLD III/IV) underwent three-dimensional high resolution computed tomography (3D-HRCT) and contrast-enhanced magnetic resonance (MR) perfusion. 3D-HRCT data was visually analyzed for emphysema phenotyping and quantification by consensus of three experts in chest-radiology. The predominant phenotype per segment was categorized as normal, centrilobular, panlobular or paraseptal. Segmental lung perfusion was visually analyzed using six patterns of pulmonary perfusion (1-normal; 2-mild homogeneous reduction in perfusion; 3-heterogeneous perfusion without focal defects; 4-heterogeneous perfusion with focal defects; 5-heterogeneous absence of perfusion; 6-homogeneous absence of perfusion), with the extent of the defect given as a percentage. 730 segments were evaluated. CT categorized 566 (78 %) as centrilobular, 159 (22 %) as panlobular and 5 (<1 %) as paraseptal with no normals. Scores with regards to MR perfusion patterns were: 1-0; 2-0; 3-28 (4 %); 4-425 (58 %); 5-169 (23 %); 6-108 (15 %). The predominant perfusion pattern matched as follows: 70 % centrilobular emphysema - heterogeneous perfusion with focal defects (score 4); 42 % panlobular - homogeneous absence of perfusion (score 5); and 43 % panlobular - heterogeneous absence of perfusion (score 6). MR pulmonary perfusion patterns correlate with the CT phenotype at a segmental level in patients with severe emphysema. (orig.)

  18. Assessment of the relationship between morphological emphysema phenotype and corresponding pulmonary perfusion pattern on a segmental level

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Mark; Kauczor, Hans-Ulrich [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Ley, Sebastian [Chirurgische Klinik Dr. Rinecker, Department of Diagnostic and Interventional Radiology, Munich (Germany); Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany); Eberhardt, Ralf; Herth, Felix [Thoraxklinik University of Heidelberg, Department of Pneumology and Critical Care Medicine, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Menezes, Ravi [University of Toronto, Medical Imaging, Toronto (Canada); Sedlaczek, Oliver [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Ley-Zaporozhan, Julia [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany)

    2015-01-15

    Distinct morphological emphysema phenotypes were assessed by CT to show characteristic perfusion defect patterns. Forty-one patients with severe emphysema (GOLD III/IV) underwent three-dimensional high resolution computed tomography (3D-HRCT) and contrast-enhanced magnetic resonance (MR) perfusion. 3D-HRCT data was visually analyzed for emphysema phenotyping and quantification by consensus of three experts in chest-radiology. The predominant phenotype per segment was categorized as normal, centrilobular, panlobular or paraseptal. Segmental lung perfusion was visually analyzed using six patterns of pulmonary perfusion (1-normal; 2-mild homogeneous reduction in perfusion; 3-heterogeneous perfusion without focal defects; 4-heterogeneous perfusion with focal defects; 5-heterogeneous absence of perfusion; 6-homogeneous absence of perfusion), with the extent of the defect given as a percentage. 730 segments were evaluated. CT categorized 566 (78 %) as centrilobular, 159 (22 %) as panlobular and 5 (<1 %) as paraseptal with no normals. Scores with regards to MR perfusion patterns were: 1-0; 2-0; 3-28 (4 %); 4-425 (58 %); 5-169 (23 %); 6-108 (15 %). The predominant perfusion pattern matched as follows: 70 % centrilobular emphysema - heterogeneous perfusion with focal defects (score 4); 42 % panlobular - homogeneous absence of perfusion (score 5); and 43 % panlobular - heterogeneous absence of perfusion (score 6). MR pulmonary perfusion patterns correlate with the CT phenotype at a segmental level in patients with severe emphysema. (orig.)

  19. The use of radioisotope techniques for the diagnosis of obstructive airway disease

    International Nuclear Information System (INIS)

    Furudate, Masatsugu; Itoh, Kazuo; Shida, Akira; Minami, Yukisato

    1981-01-01

    Perfusion scintigraphy, radioaerosol inhalation scintigraphy, 133 Xe studies and sup(81m)Kr studies are useful radioisotope techniques for the detection of regional pulmonary abnormalities in obstructive airway disease. The patient during asthmatic attack shows the perfusion defects with indefinite boundary, which may change during the following several days. Decreased ventilation are seen on the regions with perfusion defects, and ventilatory defects are more marked than those of perfusion. On the other hand, these abnomal findings is reversible. In chronic emphysema or chronic bronchitis, the regions with decreased perfusion usually cannot be correlated with any specific segments, and scintigraphys done repeatedly fail to show re-vascularization on the regions. In the radioaerosol inhalation scintigraphy, deposition pattern reveal the severity of COPD. In addition, xenon studies in the diseases show marked or moderate prolongation of wash-out from the abnormal region, and the abnormalities of ventilation are equal to or exceed the abnormalities of perfusion. (author)

  20. Use of radioisotope techniques for the diagnosis of obstructive airway disease

    Energy Technology Data Exchange (ETDEWEB)

    Furudate, M; Itoh, K; Shida, A; Minami, Y [Hokkaido Univ., Sapporo (Japan). School of Medicine

    1981-07-01

    Perfusion scintigraphy, radioaerosol inhalation scintigraphy, /sup 133/Xe studies and sup(81m)Kr studies are useful radioisotope techniques for the detection of regional pulmonary abnormalities in obstructive airway disease. The patient during asthmatic attack shows the perfusion defects with indefinite boundary, which may change during the following several days. Decreased ventilation are seen on the regions with perfusion defects, and ventilatory defects are more marked than those of perfusion. On the other hand, these abnomal findings are reversible. In chronic emphysema or chronic bronchitis, the regions with decreased perfusion usually cannot be correlated with any specific segments, and scintigraphys done repeatedly fail to show re-vascularization on the regions. In the radioaerosol inhalation scintigraphy, deposition pattern reveal the severity of COPD. In addition, xenon studies in the diseases show marked or moderate prolongation of wash-out from the abnormal region, and the abnormalities of ventilation are equal to or exceed the abnormalities of perfusion.

  1. Three-dimensional surface display with [sup 123]I-IMP brain perfusion imaging in patients with dementia

    Energy Technology Data Exchange (ETDEWEB)

    Tomino, Yoshio; Tachibana, Hisao; Sugita, Minoru [Hyogo Coll. of Medicine, Nishinomiya (Japan)

    1994-04-01

    We reconstructed three-dimensional (3D) surface images from SPECT data with N-isopropyl-p [[sup 123]I]-iodo-amphetamine ([sup 123]I-IMP) in 27 patients with Parkinson's disease (group 1), 16 patients with Alzheimer's disease (group 2), 9 patients with Binswanger's disease (group 3), and 11 elderly normal subjects (control group). Three-D reconstruction was performed using distance-shaded method at the threshold levels at intervals of 5% from 45% to 80%. In the control group, no perfusion defects were found in any region at threshold values below 60%, although the frontal and temporal cortices occasionally showed perfusion defects at threshold levels from 60% to 80%. In the group 1 of patients with dementia, perfusion defects were diffuse, particularly in the parietal and temporal cortices even at a threshold of 45%. The group 2 also showed diffuse perfusion defects, particularly in parietal and temporal cortices even at threshold levels as low as 45%. The primary visual cortex was less affected in this group. The demented patients in the group 1 demonstrated perfusion defects similar to those of patients in the group 2, although perfusion defects were more prominent in the group 2. In the group 3, patchy perfusion defects were found most frequently in the frontal region. Perfusion defects in the cerebellum and sensory motor cortex were more frequent in the group 3 than the other two groups, as well as the control group. The demented patients in the group 1 showed perfusion defects in the temporal and parietal cortices and demonstrated a perfusion pattern similar to those in the group 2. The patterns of brain perfusion in the group 3 were obviously different from those in the other two groups. In conclusion, 3D surface display of brain perfusion imaging may be useful for evaluating the cortical hypoperfusion regions in patients with dementia. It may also be of value in the differential diagnosis of cognitive disorders. (J.P.N.).

  2. Pre- and postoperative ventilation-perfusion scan findings in patients undergoing total hip replacement or knee arthroplasty

    International Nuclear Information System (INIS)

    Kim, S.M.; Park, C.H.; Intenzo, C.M.

    1988-01-01

    Venous thrombolembolism is one of the major postoperative complications in patients undergoing total hip replacement (THR) or knee anthroplasty (TKA). The reported incidence of pulmonary embolism in this group is as high as 20%. The purpose of this report was to evaluate the value of preoperative and 7th-day postpoperative ventilation-perfusion (V/Q) lung scans in the management of patients undergoing elective reconstructive surgery of the hips or knees. Routine preoperative and 7th-day postoperative V/Q lung scans were obtained in 34 patients who underwent THR (17 patients) or TKA (17 patients). There were 15 male and 19 female patients, with an age distribution ranging from 56 to 80 years. Chest radiographs were obtained within 1 day of the pre- or postoperative lungs scan. Lung scans were interpreted by two experienced nuclear physicians

  3. The matching of ventilation and perfusion in the lung of the Tegu lizard, Tupinambis nigropunctatus.

    Science.gov (United States)

    Hlastala, M P; Standaert, T A; Pierson, D J; Luchtel, D L

    1985-06-01

    Ventilation-perfusion (VA/Q) distribution was evaluated in the Tegu lizard, Tupinambis nigropunctatus, using the multiple inert gas elimination technique (MIGET) in order to define the limitations to gas exchange in the large chambered unicameral lung. The lizards (0.52-1.1 kg) were anesthetized with halothane and ventilated. Body temperature was maintained at 35 degrees C. Arterial and sinus venosus PO2 averaged 79.4 +/- 5.9 and 47.3 +/- 6.4 torr while breathing air and 232.1 +/- 31 and 64.8 +/- 11.5 torr while breathing oxygen. VA/Q distributions were broad and right-to-left shunt averaged 21% while breathing air and 27% while breathing oxygen. Gas exchange was significantly impaired due to the presence of both shunt and VA/Q heterogeneity. The walls of the lung enclose a large axial air chamber. Microscopic examination revealed approximately three generations of septa which subdivided the wall into tubular-shaped gas-exchange chambers. Wall thickness averages 2.8 mm at the anterior end of the lung, 2.1 mm in the middle portion of the lung and 1.4 mm at the posterior end. The thickness of the blood-air barrier (epithelial-basal lamina-endothelial cell layer) ranged from 0.35 to 0.90 micron. Although this barrier is slightly thicker than in the mammalian lung (0.1-0.5 micron), it is unlikely to be a source of diffusion limitation in gas exchange at rest.

  4. Lung perfusion scintigraphy by SPECT

    International Nuclear Information System (INIS)

    Hirayama, Takanobu

    1990-01-01

    The initial study reports the characteristic performance using lung segmental phantom filled in Tc-99m pertechnetate. To evaluate the segmental defect in lung perfusion scintigraphy, we applied Bull's-eye analysis in addition to planar image set. Bull's-eye analysis especially facilitated the interpretation in both middle and lower lobes. Subsequently, to evolute the clinical application of Bull's-eye analysis, pulmonary scintigraphy was performed on 10 normal subjects and 60 patients with several pulmonary diseases. Of interest, Bull's-eye analysis, however, encouraged the interpretation in both lower lobes. To calculate the extention and severity of perfusion defect, the present study describes Bull's-eye analysis. Quantitative scoring showed higher in patients with lung cancer than those with pulmonary tuberculosis. The present study focus that Bull's-eye analysis can be useful for evaluating perfusion in patients with a couple of pulmonary diseases. (author)

  5. Radiospirometry and perfusion scintigraphy in cases of limited pulmonary fibrosis

    International Nuclear Information System (INIS)

    Tarkowska, A.; Smajkiewicz, L.; Szarewicz-Adamczyk, W.; Zaorska-Rajca, J.; Woytowicz, A.; Patyra, S.

    1981-01-01

    In 60 cases of limited pulmonary fibrosis radiospirometric investigation was performed using 133 Xe and a four-channel set. Perfusion scintigraphy was done as well after administration of labelled molecules. In all patients abnormalities were found in the results of both isotope methods suggesting presence of disturbances in the regional pulmonary functions. These disturbances included impairment of perfusion as well as ventilation, with evidence of obturation, increased volume of residual air, and decreased vital and total capasity of the lungs. These abnormalities occurred exclusively or most intensively in the areas corresponding to the location of the anatomical change, and in a considerable proportion of cases they were more extensive than the radiological changes. In about 40% of the patients in the contralateral lung diffuse changes of perfusion and ventilation were present, although much less intense, suggesting concomitant chronic obturative disease. The authors think that perfusion scintigraphy and radiospirometry owing to their value as a method of assessing pulmonary function are useful in cases of pulmonary fibrosis for establishing treatment methods and for evaluating disability to work. (author)

  6. Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography

    International Nuclear Information System (INIS)

    Nekolla, S.G.; Miethaner, C.; Nguyen, N.; Ziegler, S.I.; Schwaiger, M.

    1998-01-01

    The purpose of this study was to determine the reliability of new software developed for the analysis of cardiac tomographic data. The algorithm delineates the long axis and defines the basal plane and subsequently generates polar maps to quantitatively and reproducibly assess the size and severity of perfusion defects. The developed technique requires an initial manual estimate of the left ventricular long axis and calculates the volumetric maximum myocardial activity distribution. This surface is used to map three-dimensional tracer accumulation onto a two-dimensional representation (polar map), which is the basis for further processing. The spatial information is used to compute geometrical and mechanical properties of a solid model of the left ventricle including the left heart chamber. A new estimate of the axis is determined from this model, and the previously outlined procedure is repeated together with an automated definition of the valve plane until differences between the polar maps can be neglected. This quantitative analysis software was validated in phantom studies with defects of known masses and in ten data sets from normals and patients with coronary artery disease of various severity. We investigated the reproducibility of the maps with the introduction of a similarity criterion where the ratio of two corresponding polar map elements lies within a 10% interval. The maps were also used to measure intra-and interobserver variability in respect of defect size and severity. In the phantom studies, it was possible to reliably assess mass information over a wide range of defects from 5 to 60 g (slope: 1.02, offset -0.68, r = 0.972). Patient studies revealed a statistically significant increase in the reproducibility of the automatic technique compared with the manual approach: 54%±19% (manual) compared with 88%±9% (automatic) for observer 1 and 61%±20% vs 82%±5% for observer 2, respectively. The intervariability analysis showed a significant

  7. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Kyung Il; Lee, Young Ju [Ajou Univ. College of Medicine, Seoul (Korea, Republic of); Lim, Tae Hwan [Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of)] [and others

    1997-11-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and {sup 99m}Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4{+-}5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42{+-}0.52 and 2.16{+-}0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia.

  8. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Lee, Young Ju; Lim, Tae Hwan

    1997-01-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and 99m Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4±5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42±0.52 and 2.16±0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia

  9. Myocardial perfusion imaging with dual energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Spandorfer, Adam; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)

    2016-10-15

    Highlights: • Stress dual-energy sCTMPI offers the possibility to directly detect the presence of myocardial perfusion defects. • Stress dual-energy sCTMPI allows differentiating between reversible and fixed myocardial perfusion defects. • The combination of coronary CT angiography and dual-energy sCTMPI can improve the ability of CT to detect hemodynamically relevant coronary artery disease. - Abstract: Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  10. Time-resolved MR angiography of the renal artery: morphology and perfusion

    International Nuclear Information System (INIS)

    Krause, U.J.; Pabst, T.; Koestler, H.; Helbig, C.; Kenn, W.; Hahn, D.

    2002-01-01

    Purpose: To prove the hypothesis that renal artery stenosis and changes in renal perfusion can be detected with contrast-enhanced time-resolved MR angiography in a single examination. Material and Methods: In 71 patients, 137 renal arteries and 14 accessory renal arteries were studied. The examinations were performed on a 1.5 T system. A T 1 -weighted gradient echo sequence with a temporal resolution of 7 s was used. Single dose of contrast material (0.1 mmol/kg Gd-DTPA) was injected with a power injector with a flow rate of 2 ml/s. Criterion for the assessment of renal perfusion was the slope ratio of the signal intensity time curve in both kidneys. Results: Forty renal artery stenoses and one occlusion of a renal artery were detected. In 48 kidneys (35%) segmental arteries were evaluated. The accuracy of the slope ratio (limit value 0.75) concerning the detection of unilateral renal artery stenosis was 92.6% (sensitivity 75%, specificity 95.7%). Conclusion: Time-resolved MR angiography can detect changes in renal perfusion in patients with unilateral renal artery stenosis. (orig.) [de

  11. Pulmonary ventilation in children digital subtraction study

    International Nuclear Information System (INIS)

    Schmit, P.; Faure, C.; Sardet, A.; Bacques, O.

    1985-01-01

    Digital technique such as used in digital angiography can be used to study areas which lucency varies with time. A TID technique (time interval difference) has been used to study the lucency variation of the lung in children. This method has been used in 130 children with a mean age of 2 years and 8 months. In 85 children, the TID was normal: 5 false negative studies were found in this group. In the other 47 cases, the anomaly of the TID was due to a perfusion or a ventilation anomaly or both. No false positive are found. In 13 patients, comparison between the TID findings and the perfusion and ventilation nuclear scan was possible. In 9 patients, the correlation was excellent, the TID giving more some informations about the pulmonary mixic [fr

  12. MYOCARDIAL PERFUSION ASSESSMENT IN FORECASTING EFFECT OF CORONARY ANGIOPLASTY IN PATIENTS WITH ISCHEMIC CHRONIC HEART FAILURE

    Directory of Open Access Journals (Sweden)

    A. B. Mironkov

    2015-01-01

    Full Text Available Aim. To define influence of the left ventricle (LV perfusion defects on the clinical status dynamics after coronary angioplasty in patients with the expressed myocardium dysfunction of ischemic etiology. Materials and methods. Examined 86 patients (81 men and 5 women aged from 46 to 73 years before and in 2–3 days after percutaneous coronary intervention with diagnosis: CAD, CHF with NYHA class III–IV, echocardiography parameters of LV: ejection fraction less than 40%, end-diastolic volume is more than 200 ml. Perfusion defects of myocardium estimated with use of ECG-gated single photon emission computed tomography. Predictors were defined: perfusion defects on LV apex (in score, perfusion defects in the area of LAD, LCx and RCA (%, the LV global perfusion defects (in score and %. Results. In 42% of cases 6-minute walk test increased to 3 times; The NYHA class decreased by 2 classes (group 1. In 28 cases 6-minute walk test increased to 2 times and the NYHA class decreased on 1 class. In 22 patients 6-minute walk test increased less than 50% of reference values and there was no dynamics NYHA class (50 patients of the group 2. Initial extent of LV global perfusion defects in group 1 – 41,2 ± 4,0%, in group 2 – 58,3 ± 2,4% (р = 0,0004. Similar values are received for perfusion indicators in the area of LAD and the LV apex. Prevalence of myocardial perfusion defects at rest reflects prevalence of a cardiosclerosis in a cardiac muscle. Conclusion. Degree of LV myocardial perfusion defects in patients with the expressed heart failure of ischemic etiology is the key indicator influencing clinical efficiency of coronary angioplasty. Critical size for definition of the favorable forecast of revascularization are 60% and more perfusion defects testifying that in a cardiac muscle the focal cardiosclerosis prevails over the functioning myocardium. 

  13. Myocardial perfusion as an indicator of graft patency after coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Kolibash, A.J.; Call, T.D.; Bush, C.A.; Tetalman, M.R.; Lewis, R.P.

    1980-01-01

    Stress and resting myocardial perfusion were assessed in 38 patients who received 96 grafts. Stress perfusion was evaluated with thallium-201 and resting myocardial blood flow distribution with radiolabeled particles. When both stress and rest perfusion were normal, graft patency was 82% (51 of 62 grafts). Graft patency was also high (81%, 13 of 16) in areas where stress perfusion abnormalities resolved or become less apparent at rest. However, when stress perfusion defects remained unchanged at rest, the graf was likely to be occuluded (73%, 11 of 15). Maintenance of normal rest perfusion or improvement of rest perfusion postoperatively was also associated with a high graft patency rate (80%, 35 of 44), whereas the development of new rest perfusion defects postoperatively implied graft occlusion

  14. Unilateral re-expansion pulmonary oedema treated with C-PAP

    Directory of Open Access Journals (Sweden)

    Giovanni Volpicelli

    2009-06-01

    Full Text Available Unilateral re-expansion pulmonary oedema is a rare but dangerous complication of treatment for pulmonary atelectasis, pleural effusion and pneumothorax, whose pathogenesis is not completely known. The clinical picture varies considerably from asymptomatic forms with positive radiographic findings to forms with severe respiratory insufficiency and haemodynamic instability. Little data is available in literature on the treatment of re-expansion pulmonary oedema with non-invasive continuous positive airway pressure ventilation. In this article, we describe the case of a 75 year-old man who reported to our Emergency Department with extensive spontaneous left pneumothorax. Following placement of the transthoracic drain, the patient presented a clinical picture of severe respiratory insufficiency with circulatory collapse caused by unilateral re-expansion pulmonary oedema. The case was successfully treated with the application of non-invasive continuous positive airway pressure ventilation. The article briefly discusses current knowledge with regard to the aetiological and pathogenetic factors of this complication of emergency pneumothorax treatment.

  15. Enhanced magnetic resonance pulmonary perfusion imaging in diagnosing pulmonary embolism: preliminary investigation

    International Nuclear Information System (INIS)

    Huang Xiaoyong; Du Jing; Zhang Zhaoqi; Guo Xi; Yan Zixu; Jiang Hong; Wang Wei

    2005-01-01

    Objective: This study was designed to investigate the sensitivity and specificity of magnetic resonance pulmonary perfusion imaging (MRPP) in diagnosing pulmonary embolism (PE) compared with enhanced magnetic resonance pulmonary angiography (MRPA) and pulmonary radionuclide perfusion imaging. Methods: Fourteen patients were definitely diagnosed as PE, whose ages were from 19 to 71 years old and mean 45.5 ± 19.8 years old. All patients under went MRPA and MRPP and 3 patients were examined again after thrombolytic treatment. Five patients underwent pulmonary radionuclide perfusion imaging. Setting ROI in top, middle, bottom of lung area and abnormal area respectively, we detected signal intensity and time-signal curve to obtain the transformation rate of signal (TROS) during perfusion peak value. Results: In 14 pulmonary embolism patients, MRPA found 62 branches of pulmonary artery obstruction. Fifty-five abnormal pulmonary perfusion zones were found by MRPP, and the above results were very alike. The coincidence was 88.71%. In 14 cases, MRPP could show 25 subsegments lesion below segments. In 5 patients who had both results Of MRPP and ECT at the same time. MRPP shows 33 perfusion defect zones and 37 segments were found by ECT, the sensitivity was 89.19%. After thrombolytic treatment, both the status of the affected pulmonary artery improved markedly and perfusion defect zones reduced obviously in 3 cases by MRPP and MRPA. TROS in normal perfusion zones perfusion defect zones and low perfusion zones had significant difference (t=22.882, P<0.01). Conclusion: Contrast enhanced MR pulmonary perfusion can show both perfusion defect zones and low perfusion zones in pulmonary embolism. Time-signal curve can show the period of maximum no perfusion zones in pulmonary artery embolism zones. And the amplitude of fluctuation is small with miminum TROS. MRPP has significant values especially in showing pulmonary artery embolism in segments and subsegments. Using both MRPP and

  16. Myocardial perfusion abnormality and chest pain in patients with hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1991-01-01

    To investigate the role of myocardial ischemia in the development of chest pain in patients with hypertrophic cardiomyopathy (HCM), exercise stress (Ex) redistribution myocardial single photon emission CT's (SPECT's) with thallium-201 (Tl) were obtained in 27 patients with HCM. In all patients, coronary arteries were normal arteriographically. Patients were classified into NYHA Class I, II and III according to the frequency and severity of the chest pain during daily life. In these 3 groups, age, sex and intraventricular septal thickness measured by echocardiography were not different. Types of myocardial perfusion obtained by myocardial SPECT's were divided into 5: (1) normal perfusion, (2) no perfusion defect with abnormal myocardial Tl washout rate (WOR) during 3 hours (<30%) [Def(-)/WORabn], (3) reversible perfusion defect (RD), (4) fixed defect with abnormal WOR (FD/WORabn), and (5) fixed defect with normal WOR (FD/WORnl). In 14 patients of Class I, 9 patients (64%) showed normal perfusion but the rest showed perfusion abnormality (def(-)/WORabn in 3 and RD in 2). In Class II and III, all patients showed perfusion abnormalities of RD, FD/WORabn or FD/WORnl. As the functional class progressed from Class II to III, the ratio of fixed defect (both WORnl and WORabn) to RD increased, but it was not statistically significant. In 2 patients in whom Ex SPECT's were repeated because of the progression of the chest pain, the severity of the perfusion abnormality also progressed. Perfusion abnormalities were observed most frequently in anterior (35%), then inferior/posterior (20%) and septal wall (18%). The frequency of Ex induced ECG abnormalities (ST-depression or T wave changes) increased as the NYHA Class progressed (Class III vs I p<0.05). These findings suggested the following: chest pain in patients with HCM relates to the myocardial ischemia which may originate in the myocardial small arteries, and when the lesions progress myocardial necrosis may ensue. (author)

  17. Impairment of myocardial perfusion in children with sickle cell disease; Alteration de la perfusion myocardique chez l'enfant drepanocytaire

    Energy Technology Data Exchange (ETDEWEB)

    Maunoury, C. [Hopital Necker-Enfants-Malades, Service de Medecine Nucleaire, 75 - Paris (France); Acar, P. [Centre Hospitalier Universitaire, Hopital des Enfants, Service de Cardiologie Pediatrique, 31 - Toulouse (France); Montalembert, M. de [Hopital Necker-Enfants-Malades, Service de Pediatrie Generale, 75 - Paris (France)

    2003-10-01

    While brain, bone and spleen strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Non invasive techniques such as exercise testing and echocardiography have a low sensitivity to detect myocardial ischemia in patients with SCD. We have prospectively assessed myocardial perfusion with Tl-201 SPECT in 23 patients with SCD (10 female, 13 male, mean age 12 {+-} 5 years). Myocardial SPECT was performed after stress and 3 hours later after reinjection on a single head gamma camera equipped with a LEAP collimator (64 x 64 matrix size format, 30 projections over 180 deg C, 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Myocardial perfusion was impaired in 14/23 patients: 9 reversible defects and 5 fixed defects. The left ventricular cavity was dilated in 14/23 patients. The mean LVEF was 63 {+-} 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. The frequent impairment of myocardial perfusion in children with SCD could lead to suggest a treatment with hydroxyurea, an improvement of perfusion can be noted with hydroxyurea. (author)

  18. Comparison of /sup 133/Xe washout curves after bolus inhalation, perfusion, and equilibration

    Energy Technology Data Exchange (ETDEWEB)

    Devos, P; Demedts, M; Vandecruys, A; Cosemans, J; De Roo, M

    1978-01-01

    In 6 healthy subjects and 13 patients with chronic obstructive lung disease, /sup 133/Xe washout curves after bolus inhalation, perfusion and equilibration were compared, using a gamma camera and computerized data handling. In healthy subjects the washout after equilibration was significantly slower than after the two other procedures. As this phenomenon occurred at the basal zones, it was attributed to the presence of airway closure in some units. In patients, the three washouts were significantly different from each other. This indicated the existence of intraregional inhomogeneity in ventilation, perfusion and ventilation-perfusion ratio. Our conclusion is that comparison of these different washout methods yields valuable information not only on absolute values of pulmonary function but also on the intraregional distribution, which cannot be obtained by other examinations.

  19. HMPAO-SPECT in dementia of the Alzheimer type and major depression with memory impairment. HMPAO-SPECT bei Demenz vom Alzheimer-Typ und Major Depression mit mnestischen Stoerungen

    Energy Technology Data Exchange (ETDEWEB)

    Gruenwald, F [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Horn, R [Bonn Univ., Psychiatrische Klinik (Germany); Rieker, O [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Klemm, E [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Menzel, C [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Moeller, H J [Bonn Univ., Psychiatrische Klinik (Germany); Biersack, H J [Bonn Univ., Klinik fuer Nuklearmedizin (Germany)

    1993-06-01

    The aim of the present study was to see whether HMPAO-SPECT may contribute to the differentiation between dementia of the Alzheimer type (DAT) and major depression (MD). The results in 77 patients with memory impairment were evaluated. 48 patients suffered from DAT and 29 from MD. Initially, the defects in SPECT imaging were attributed to a cerebral region and the degree of decrease was evaluated (-1/-2/-3). Thereafter, the results were classified by 7 categories. In some of these categories an accumulation of cases of either DAT or MD was found. 35% of the patients suffering from DAT had bilateral defects with distinct (>-1) parietal/parietotemporal hypoperfusions, but no patient with MD showed this perfusion pattern. 62% of the patients with MD had unilateral defects but only 31% of the patients with DAT. The present study demonstrates that only 35% of all patients suffering from DAT show a perfusion pattern, thought earlier as ''pathognomonic'' for this disease. This perfusion pattern - if it exists - may be used as a safe criterion to exclude MD. Beyond that no clearcut (''specific'') perfusion pattern may be recognized but unilateral defects point to MD. (orig.)

  20. HMPAO-SPECT in dementia of the Alzheimer type and major depression with memory impairment

    International Nuclear Information System (INIS)

    Gruenwald, F.; Horn, R.; Rieker, O.; Klemm, E.; Menzel, C.; Moeller, H.J.; Biersack, H.J.

    1993-01-01

    The aim of the present study was to see whether HMPAO-SPECT may contribute to the differentiation between dementia of the Alzheimer type (DAT) and major depression (MD). The results in 77 patients with memory impairment were evaluated. 48 patients suffered from DAT and 29 from MD. Initially, the defects in SPECT imaging were attributed to a cerebral region and the degree of decrease was evaluated (-1/-2/-3). Thereafter, the results were classified by 7 categories. In some of these categories an accumulation of cases of either DAT or MD was found. 35% of the patients suffering from DAT had bilateral defects with distinct (>-1) parietal/parietotemporal hypoperfusions, but no patient with MD showed this perfusion pattern. 62% of the patients with MD had unilateral defects but only 31% of the patients with DAT. The present study demonstrates that only 35% of all patients suffering from DAT show a perfusion pattern, thought earlier as ''pathognomonic'' for this disease. This perfusion pattern - if it exists - may be used as a safe criterion to exclude MD. Beyond that no clearcut (''specific'') perfusion pattern may be recognized but unilateral defects point to MD. (orig.) [de

  1. Diagnosis of thromboembolic disease: combined ventilation perfusion lung scan and compression ultrasonography

    International Nuclear Information System (INIS)

    Dadparvar, S.; Woods, K.; Magno, R.M.; Sabatino, J. C.; Patil, S.; Dou, Y.

    2002-01-01

    The clinical management of pulmonary embolism and deep venous thrombosis of the legs are similar and require prolonged anticoagulation therapy. The standard diagnostic approach in patients suspected of pulmonary embolism is ventilation-perfusion (V/Q) lung scan and compression ultrasonography to detect deep venous thrombosis. This retrospective study analyzed the role of V Q lung scan and compression ultrasonography in detection of thromboembolic disease. One hundred-twenty consecutive patients (65 female, 55 male) age range 18-95 (mean age 60.7) suspected for pulmonary embolism underwent concomitant V/Q lung scan and compression ultrasonography of the lower extremities. The clinical and radiographic correlation was performed. Of patients with non-diagnostic (low or intermediate probability ) lung scans, 15.4 % (14/91) received anticoagulation therapy for pulmonary embolism. This patients had either high pre-clinical suspicion for PE or underwent pulmonary arterio gram. However, there was an additional 7 % (7/91) increase in the number of patients who received anticoagulation therapy based on the results of ultrasound with confidence interval (3 %-16 %). We conclude that V/Q lung scan is a more sensitive examination for thromboembolic disease, and has a high negative predictive value. Ultrasonography of lower extremities demonstrated higher specificity and positive value. Among patients with non-diagnostic lung scan, the detection rate of thromboembolic disease is improved with addition of ultrasound

  2. The effects of exogenous surfactant administration on ventilation-induced inflammation in mouse models of lung injury.

    Science.gov (United States)

    Puntorieri, Valeria; Hiansen, Josh Qua; McCaig, Lynda A; Yao, Li-Juan; Veldhuizen, Ruud A W; Lewis, James F

    2013-11-20

    Mechanical ventilation (MV) is an essential supportive therapy for acute lung injury (ALI); however it can also contribute to systemic inflammation. Since pulmonary surfactant has anti-inflammatory properties, the aim of the study was to investigate the effect of exogenous surfactant administration on ventilation-induced systemic inflammation. Mice were randomized to receive an intra-tracheal instillation of a natural exogenous surfactant preparation (bLES, 50 mg/kg) or no treatment as a control. MV was then performed using the isolated and perfused mouse lung (IPML) set up. This model allowed for lung perfusion during MV. In experiment 1, mice were exposed to mechanical ventilation only (tidal volume =20 mL/kg, 2 hours). In experiment 2, hydrochloric acid or air was instilled intra-tracheally four hours before applying exogenous surfactant and ventilation (tidal volume =5 mL/kg, 2 hours). For both experiments, exogenous surfactant administration led to increased total and functional surfactant in the treated groups compared to the controls. Exogenous surfactant administration in mice exposed to MV only did not affect peak inspiratory pressure (PIP), lung IL-6 levels and the development of perfusate inflammation compared to non-treated controls. Acid injured mice exposed to conventional MV showed elevated PIP, lung IL-6 and protein levels and greater perfusate inflammation compared to air instilled controls. Instillation of exogenous surfactant did not influence the development of lung injury. Moreover, exogenous surfactant was not effective in reducing the concentration of inflammatory cytokines in the perfusate. The data indicates that exogenous surfactant did not mitigate ventilation-induced systemic inflammation in our models. Future studies will focus on altering surfactant composition to improve its immuno-modulating activity.

  3. Is there any advantage to the acquisition of 24-hour thallium images, in the presence of persistent perfusion defects at 4 h after reinjection?

    Science.gov (United States)

    Bobba, K; Botvinick, E H; Sciammarella, M G; Starsken, N F; Zhu, Y Y; Lapidus, A; Dae, M W

    1998-05-01

    We determined the incidence of delayed 24-h reversibility post thallium-201 reinjection and imaging at 4 h, as well as the prognostic and significance of such delayed reversibility. We studied 46 consecutive patients with persistent thallium-201 perfusion or incompletely reversible single-photon emission tomography (SPET) perfusion defects acquired within 10 min after reinjection performed 4 h after stress. In 38 of 46 patients (82%) 24-h images showed no further reversibility beyond the post-reinjection 4-h study (group A). Eight of 46 patients (17%) demonstrated reversibility on 24-h imaging (group B). Of these eight, three patients showed no improvement compared with the post-stress images, with a mean perfusion score of the abnormal segments of 1. 25+/-0.50 on the 4-h images, and of 3.00 on the 24-h images, where normal is 4. Four patients presented with nine mixed regions. Four of these regions showed an improvement in the mean perfusion score of 2.50+/-0.58 on 4- and 24-h images. Two of them, with moderate/severe defects, demonstrated complete reversibility at 4-h post-reinjection imaging. In addition, five other regions presented no improvement at 4-h imaging, but showed an improvement in the mean perfusion score from 0.80+/-0.84 at 4-h to 3.30+/-0.89 at 24-h imaging. Two of these regions in one patient showed a severe perfusion score of 0 at 4 h, and complete reversibility at 24 hours, with a mean score improvement of 4. Another patient had three severe perfusion defects; two of them redistributed partially at 4 h and completely at 24 h. The remaining segment with a perfusion score of 0 at 4 h, presented complete reversibility with a score of 4 at 24 h. Two (4%) patients revealed significant reversibility at 24 h in a region that was severely underperfused after post-reinjection imaging at 4 h. Among group B patients, 75% (6/8) had recent acute ischemic syndrome, compared with only 13% (5/38) in group A (P = 0. 001). Among 11 patients with unstable angina

  4. Ventilation studies of the lung with krypton-81m

    International Nuclear Information System (INIS)

    Klopper, J.F.; Baard, W.P.; Van Heerden, P.D.R.

    1981-01-01

    During a 2-year study period it was found that krypton-81m was useful in clinical practice. During this period 1563 technetium-99m perfusion studies and 807 krypton-81m ventilation studies were performed. A distinct advantage of krypton-81m was the ease with which multiple views could be obtained. These views could be directly compared with those of preceding perfusion studies. However, interruptions in the regular supply of rubidium-81/krypton-81m generators affected 17,1% of perfusion studies and xenon-127 should be a suitable substitute for these periods

  5. Decreased perfusion in myocardial region of normal donor artery secondary to collateral development

    International Nuclear Information System (INIS)

    Koga, Y.; Takahashi, M.; Kojima, A.; Takaki, Y.; Tomiguchi, S.; Hirota, Y.; Kugiyama, K.; Yasue, H.; Hayasaki, K.; Kumamoto Saiseikai Hospital

    1992-01-01

    Thirty-one patients suffering from single vessel exertional angina with collaterals (Group A) were evaluated by stress 201 Tl myocardial emission CT (Tl-SPECT) with 16 controls of severely stenotic single vessel exertional angina without collaterals (Group B). Group A included 21 patients (68%) who showed an extensive perfusion defect in double artery myocardial regions, including the normal donor artery myocardial region (DMR). However, there were no such cases in Group B, giving a significant difference between these 2 groups (p < 0.001). Four patients in Group A, having a perfusion defect both in DMR and in the collateral dependent myocardial region (CMR) underwent a successful percutaneous transluminal coronary angioplasty (PTCA) with disappearance of collaterals. Tl-SPECT findings after PTCA showed no perfusion defect either in CMR or in DMR. This has been explained on the basis that the coronary collaterals stole blood and produced perfusion defect in DMR. (orig.)

  6. Regional glucose utilization in infarcted and remote myocardium: its relation to coronary anatomy and perfusion.

    Science.gov (United States)

    Fragasso, G; Chierchia, S L; Landoni, C; Lucignani, G; Rossetti, E; Sciammarella, M; Vanoli, G E; Fazio, F

    1998-07-01

    We studied the relationship between coronary anatomy, perfusion and metabolism in myocardial segments exhibiting transient and persistent perfusion defects on stress/rest 99Tcm-MIBI single photon emission tomography in 35 patients (31 males, 4 females, mean age 56 +/- 7 years) with a previous myocardial infarction. Quantitative coronary angiography and assessment of myocardial perfusion reserve and glucose metabolism were performed within 1 week of one another. Perfusion was assessed by SPET after the intravenous injection of 740 MBq of 99Tcm-MIBI at rest and after exercise. Regional myocardial glucose metabolism was assessed by position emission tomography at rest (200 MBq of 18F-2-deoxyglucose, FDG) after an overnight fast with no glucose loading. All 35 patients exhibited persistent perfusion defects consistent with the clinically identified infarct site, and 27 (77%) also showed various degrees of within-infarct FDG uptake; 11 patients developed exercise-induced transient perfusion defects within, or in the vicinity of, 15 infarct segments and resting FDG uptake was present in 10 of these segments (67%). Five patients also showed exercise-induced transient perfusion defects in nine segments remote from the site of infarct: resting FDG uptake was present in six of these regions (67%). Finally, nine patients had increased glucose uptake in non-infarcted regions not showing transient perfusion defects upon exercise testing and perfused by coronary arteries with only minor irregularities. Our results confirm the presence of viable tissue in a large proportion of infarct sites. Moreover, FDG uptake can be seen in regions perfused by coronary arteries showing minor irregularities, not necessarily resulting in detectable transient perfusion defects on a MIBI stress scan. Since the clinical significance of such findings is not clear, further studies should be conducted to assess the long-term evolution of perfusion, function and metabolism in non

  7. /sup 67/Ga lung scan

    Energy Technology Data Exchange (ETDEWEB)

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-03-21

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate /sup 67/Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the /sup 67/Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of /sup 67/Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of /sup 67/Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography.

  8. 67Ga lung scan

    International Nuclear Information System (INIS)

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-01-01

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate 67 Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the 67 Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of 67 Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of 67 Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography

  9. Frequency and severity of myocardial perfusion abnormalities using Tc-99m MIBI SPECT in cardiac syndrome X

    International Nuclear Information System (INIS)

    Saghari, Mohsen; Assadi, Majid; Eftekhari, Mohammad; Yaghoubi, Mohammad; Fard-Esfahani, Armaghan; Malekzadeh, Jan-Mohammad; Sichani, Babak Fallhi; Beiki, Davood; Takavar, Abbas

    2006-01-01

    Cardiac syndrome X is defined by a typical angina pectoris with normal or near normal (stenosis <40%) coronary angiogram with or without electrocardiogram (ECG) change or atypical angina pectoris with normal or near normal coronary angiogram plus a positive none-invasive test (exercise tolerance test or myocardial perfusion scan) with or without ECG change. Studies with myocardial perfusion imaging on this syndrome have indicated some abnormal perfusion scan. We evaluated the role of myocardial perfusion imaging (MPI) and also the severity and extent of perfusion abnormality using Tc-99m MIBI Single Photon Emission Computed Tomography (SPECT) in these patients. The study group consisted of 36 patients with cardiac syndrome X. The semiquantitative perfusion analysis was performed using exercise Tc-99m MIBI SPECT. The MPI results were analyzed by the number, location and severity of perfusion defects. Abnormal perfusion defects were detected in 13 (36.10%) cases, while the remaining 23 (63.90%) had normal cardiac imaging. Five of 13 (38.4%) abnormal studies showed multiple perfusion defects. The defects were localized in the apex in 3, apical segments in 4, midventricular segments in 12 and basal segments in 6 cases. Fourteen (56%) of all abnormal segments revealed mild, 7(28%) moderate and 4 (16%) severe reduction of tracer uptake. No fixed defects were identified. The vessel territories were approximately the same in all subjects. The Exercise treadmill test (ETT) was positive in 25(69%) and negative in 11(30%) patients. There was no consistent pattern as related to the extent of MPI defects or exercise test results. Our study suggests that multiple perfusion abnormalities with different levels of severity are common in cardiac syndrome X, with more than 30 % of these patients having at least one abnormal perfusion segment. Our findings suggest that in these patients microvascular angina is probably more common than is generally believed

  10. Case report: Non-invasive neurally adjusted ventilatory assist in a newborn with unilateral diaphragmatic paralysis.

    Science.gov (United States)

    Roosens, Sander; Derriks, Frank; Cools, Filip

    2016-11-01

    Diaphragmatic paralysis is a rare cause of respiratory distress in the newborn. In this paper, a patient with unilateral phrenic nerve injury after traumatic delivery is presented. The child inadequately responded to standard respiratory supportive measures. Non-invasive neurally adjusted ventilatory assist (NIV-NAVA®), providing an optimally synchronized respiratory support proportional to the effort of the patient, resulted in prompt clinical and biological improvement of the patient's respiratory condition. NAVA is a relatively new mode of ventilation in neonatal care. In this case of unilateral diaphragmatic paralysis, it provided an alternative strategy of non-invasive respiratory support avoiding prolonged mechanical ventilation. Pediatr Pulmonol. 2016;51:E37-E39. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. Whole-brain 320-detector row dynamic volume CT perfusion detected crossed cerebellar diaschisis after spontaneous intracerebral hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Jun; Chen, Wei-jian; Wang, Mei-hao; Li, Jian-ce; Zhang, Qian; Xia, Neng-zhi; Yang, Yun-jun [Wenzhou Medical University, Department of Radiology, First Affiliated Hospital, Wenzhou (China); Wu, Gui-yun [Cleveland Clinics Foundation, Department of Nuclear Medicine, Imaging Institute, Cleveland, OH (United States); Cheng, Jing-liang; Zhang, Yong [Zhengzhou University, Department of Radiology, First Affiliated Hospital, Zhengzhou (China); Zhuge, Qichuan [Wenzhou Medical University, Department of Neurosurgery, First Affiliated Hospital, Wenzhou (China)

    2014-11-09

    The purpose of this study was to evaluate the value of 320-detector row CT used to detect crossed cerebellar diaschisis (CCD) in patients with unilateral supratentorial spontaneous intracerebral hemorrhage (SICH). We investigated 62 of 156 patients with unilateral supratentorial SICH using 320-detector row CT scanning. Regional cerebral blood flow (rCBF), cerebral blood volume (rCBV), mean transit time (rMTT), and time to peak (rTTP) levels were measured in different regions of interest (ROIs) that were manually outlined on computed tomography perfusion (CTP) for the cerebrum, including normal-appearing brain tissue that surrounded the perilesional low-density area (NA) and the perihematomal low-density area (PA) in all patients and the cerebellum (ipsilateral and contralateral) in CCD-positive patients. Of 62 cases, a total of 14 met the criteria for CCD due to cerebellar perfusion asymmetry on CTP maps. In the quantitative analysis, significant differences were found in the perfusion parameters between the contralateral and ipsilateral cerebellum in CCD-positive cases. No significant differences were found between the CCD-positive group and the CCD-negative group according to the hematoma volume, NIHSS scores, and cerebral perfusion abnormality (each P > 0.05). The correlation analysis of the degree of NA, PA perfusion abnormality, and the degree of CCD severity showed negative and significant linear correlations (R, -0.66∝-0.56; P < 0.05). 320-detector row CT is a robust and practicable method for the comprehensive primary imaging work-up of CCD in unilateral supratentorial SICH patients. (orig.)

  12. Whole-brain 320-detector row dynamic volume CT perfusion detected crossed cerebellar diaschisis after spontaneous intracerebral hemorrhage

    International Nuclear Information System (INIS)

    Fu, Jun; Chen, Wei-jian; Wang, Mei-hao; Li, Jian-ce; Zhang, Qian; Xia, Neng-zhi; Yang, Yun-jun; Wu, Gui-yun; Cheng, Jing-liang; Zhang, Yong; Zhuge, Qichuan

    2015-01-01

    The purpose of this study was to evaluate the value of 320-detector row CT used to detect crossed cerebellar diaschisis (CCD) in patients with unilateral supratentorial spontaneous intracerebral hemorrhage (SICH). We investigated 62 of 156 patients with unilateral supratentorial SICH using 320-detector row CT scanning. Regional cerebral blood flow (rCBF), cerebral blood volume (rCBV), mean transit time (rMTT), and time to peak (rTTP) levels were measured in different regions of interest (ROIs) that were manually outlined on computed tomography perfusion (CTP) for the cerebrum, including normal-appearing brain tissue that surrounded the perilesional low-density area (NA) and the perihematomal low-density area (PA) in all patients and the cerebellum (ipsilateral and contralateral) in CCD-positive patients. Of 62 cases, a total of 14 met the criteria for CCD due to cerebellar perfusion asymmetry on CTP maps. In the quantitative analysis, significant differences were found in the perfusion parameters between the contralateral and ipsilateral cerebellum in CCD-positive cases. No significant differences were found between the CCD-positive group and the CCD-negative group according to the hematoma volume, NIHSS scores, and cerebral perfusion abnormality (each P > 0.05). The correlation analysis of the degree of NA, PA perfusion abnormality, and the degree of CCD severity showed negative and significant linear correlations (R, -0.66∝-0.56; P < 0.05). 320-detector row CT is a robust and practicable method for the comprehensive primary imaging work-up of CCD in unilateral supratentorial SICH patients. (orig.)

  13. Computer program for regional assessment of lung perfusion defect. Part II - verification of the algorithm

    International Nuclear Information System (INIS)

    Stefaniak, B.

    2002-01-01

    As described earlier, a dedicated computer program was developed for quantitative evaluation of regional lung perfusion defects, visualized by pulmonary scintigraphy. The correctness of the basic assumptions accepted to construct the algorithms and of the all program functions needed to be checked, before application of the program into the clinical routine. The aim of this study was to verified the program using various software instruments and physical models. Evaluation of the proposed method was performed using software procedures, physical lung phantom, and selected lung image.The reproducibility of lung regions, defined by the program was found excellent. No significant distortion of registered data was observed after ROI transformation into the circle and retransformation into the original shape. The obtained results comprised parametric presentation of activity defects as well as a set of numerical indices which defined extent and intensity of decreased counts density. Among these indices PD2 and DM* were proved the most suitable for the above purposes. The obtained results indicate that the algorithms used for the program construction were correct and suitable for the aim of the study. The above algorithms enable function under study to be presented graphically with true imaging of activity distribution, as well as numerical indices, defining extent and intensity of activity defects to calculated. (author)

  14. Brain Perfusion Changes in Intracerebral Hemorrhage

    International Nuclear Information System (INIS)

    Mititelu, R.; Mazilu, C.; Ghita, S.; Rimbu, A.; Marinescu, G.; Codorean, I.; Bajenaru, O.

    2006-01-01

    Full text: Purpose: Despite the latest advances in medical treatment and neuro critical care, patients suffering spontaneous intracerebral hemorrhage (SICH) still have a very poor prognosis, with a greater mortality and larger neurological deficits at the survivors than for ischemic stroke. Many authors have shown that there are many mechanisms involved in the pathology of SICH: edema, ischemia, inflammation, apoptosis. All of these factors are affecting brain tissue surrounding hematoma and are responsible of the progressive neurological deterioration; most of these damages are not revealed by anatomical imaging techniques. The aim of our study was to asses the role of brain perfusion SPECT in demonstrating perfusion changes in SICH patients. Method: 17 SICH pts were studied. All pts underwent same day CT and brain SPECT with 99mTcHMPAO, 24h-5d from onset of stroke. Results: 14/17 pts showed a larger perfusion defect than expected after CT. In 2 pts hematoma diameter was comparable on CT and SPECT; 1pt had quasinormal aspect of SPECT study. In pts with larger defects, SPECT revealed a large cold spot with similar size compared with CT, and a surrounding hypo perfused area. 6/17 pts revealed cortical hyper perfusion adjacent to hypo perfused area and corresponding to a normal-appearing brain tissue on CT. In 3 pts we found crossed cerebellar diaskisis.In 2 pts we found cortical hypo perfused area in the contralateral cortex, with normal appearing brain tissue on CT. Conclusions: Brain perfusion SPECT revealed different types of perfusion changes in the brain tissue surrounding hematoma. These areas contain viable brain tissue that may be a target for future ne uroprotective strategies. Further studies are definitely required to demonstrate prognostic significance of these changes, but we can conclude that brain perfusion SPECT can play an important role in SICH, by early demonstrating functional changes responsible of clinical deterioration, thus allowing prompt

  15. Electrocardiographic left ventricular hypertrophy without echocardiographic abnormalities evaluated by myocardial perfusion and fatty acid metabolic imaging

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi

    2000-01-01

    The pathophysiologic process in patients with electrocardiographic left ventricular hypertrophy with ST, T changes but without echocardiographic abnormalities was investigated by myocardial perfusion imaging and fatty acid metabolic imaging. Exercise stress 99m Tc-methoxy-isobutyl isonitrile (MIBI) imaging and rest 123 I-beta-methyl-p-iodophenyl pentadecanoic acid (BMIPP) imaging were performed in 59 patients with electrocardiographic hypertrophy including 29 without apparent cause including hypertension and echocardiographic hypertrophy, and 30 with essential hypertension. Coronary angiography was performed in 6 patients without hypertension and 4 with hypertension and biopsy specimens were obtained from the left ventricular apex from 6 patients without hypertension. Myocardial perfusion and 123 I-BMIPP images were classified into 3 types: normal, increased accumulation of the isotope at the left ventricular apex (high uptake) and defect. Transient perfusion abnormality and apical defect observed by 123 I-BMIPP imaging were more frequent in patients without hypertension than in patients with hypertension (32% vs. 17%, p=0.04671 in perfusion; 62% vs. 30%, p=0.0236 in 123 I-BMIPP). Eighteen normotensive patients with apical defect by 123 I-BMIPP imaging included 3 of 10 patients with normal perfusion at exercise, 6 of 10 patients with high uptake and 9 of 9 patients with perfusion defect. The defect size revealed by 123 I-BMIPP imaging was greater than that of the perfusion abnormality. Coronary stenoses were not observed and myocardial specimens showed myocardial disarray with hypertrophy. Moreover, 9 patients with hypertension and apical defects by 123 I-BMIPP showed 3 different types of perfusion. Many patients without hypertension show a pathologic process similar to hypertrophic cardiomyopathy. Perfusion and 123 I-BMIPP imaging are useful for the identification of these patients. (author)

  16. High-resolution imaging of pulmonary ventilation and perfusion with 68Ga-VQ respiratory gated (4-D) PET/CT

    International Nuclear Information System (INIS)

    Callahan, Jason; Hofman, Michael S.; Siva, Shankar; Kron, Tomas; Schneider, Michal E.; Binns, David; Eu, Peter; Hicks, Rodney J.

    2014-01-01

    Our group has previously reported on the use of 68 Ga-ventilation/perfusion (VQ) PET/CT scanning for the diagnosis of pulmonary embolism. We describe here the acquisition methodology for 68 Ga-VQ respiratory gated (4-D) PET/CT and the effects of respiratory motion on image coregistration in VQ scanning. A prospective study was performed in 15 patients with non-small-cell lung cancer. 4-D PET and 4-D CT images were acquired using an infrared marker on the patient's abdomen as a surrogate for breathing motion following inhalation of Galligas and intravenous administration of 68 Ga-macroaggregated albumin. Images were reconstructed with phase-matched attenuation correction. The lungs were contoured on CT and PET VQ images during free-breathing (FB) and at maximum inspiration (Insp) and expiration (Exp). The similarity between PET and CT volumes was measured using the Dice coefficient (DC) comparing the following groups; (1) FB-PET/CT, (2) InspPET/InspCT, (3) ExpPET/Exp CT, and (4) FB-PET/AveCT. A repeated measures one-way ANOVA with multiple comparison Tukey tests were performed to evaluate any difference between the groups. Diaphragmatic motion in the superior-inferior direction on the 4-D CT scan was also measured. 4-D VQ scanning was successful in all patients without additional acquisition time compared to the nongated technique. The highest volume overlap was between ExpPET and ExpCT and between FB-PET and AveCT with a DC of 0.82 and 0.80 for ventilation and perfusion, respectively. This was significantly better than the DC comparing the other groups (0.78-0.79, p 68 Ga-VQ 4-D PET/CT is feasible and the blurring caused by respiratory motion is well corrected with 4-D acquisition, which principally reduces artefact at the lung bases. The images with the highest spatial overlap were the combined expiration phase or FB PET and average CT. With higher resolution than SPECT/CT, the PET/CT technique has a broad range of potential clinical applications including

  17. Disappearance of myocardial perfusion defects on prone SPECT imaging: Comparison with cardiac magnetic resonance imaging in patients without established coronary artery disease

    Directory of Open Access Journals (Sweden)

    Hedén Bo

    2009-08-01

    Full Text Available Abstract Background It is of great clinical importance to exclude myocardial infarction in patients with suspected coronary artery disease who do not have stress-induced ischemia. The diagnostic use of myocardial perfusion single-photon emission computed tomography (SPECT in this situation is sometimes complicated by attenuation artifacts that mimic myocardial infarction. Imaging in the prone position has been suggested as a method to overcome this problem. Methods In this study, 52 patients without known prior infarction and no stress-induced ischemia on SPECT imaging were examined in both supine and prone position. The results were compared with cardiac magnetic resonance imaging (CMR with delayed-enhancement technique to confirm or exclude myocardial infarction. Results There were 63 defects in supine-position images, 37 of which disappeared in the prone position. None of the 37 defects were associated with myocardial infarction by CMR, indicating that all of them represented attenuation artifacts. Of the remaining 26 defects that did not disappear on prone imaging, myocardial infarction was confirmed by CMR in 2; the remaining 24 had no sign of ischemic infarction but 2 had other kinds of myocardial injuries. In 3 patients, SPECT failed to detect small scars identified by CMR. Conclusion Perfusion defects in the supine position that disappeared in the prone position were caused by attenuation, not myocardial infarction. Hence, imaging in the prone position can help to rule out ischemic heart disease for some patients admitted for SPECT with suspected but not documented ischemic heart disease. This would indicate a better prognosis and prevent unnecessary further investigations and treatment.

  18. Unilateral lumbar spondylolysis on radiography and MRI: emphasis on morphologic differences according to involved segment.

    Science.gov (United States)

    Park, Ji Seon; Moon, Sung Kyoung; Jin, Wook; Ryu, Kyung Nam

    2010-01-01

    The objective of our study was to retrospectively compare the radiography and MRI findings of unilateral spondylolysis in the upper lumbar segment and in the lower lumbar segment and to consider how these radiologic findings can be applied in the diagnosis of unilateral spondylolysis. Thirty patients with unilateral lumbar spondylolysis were categorized into one of two groups according to the lumbar levels involved with pars interarticularis defects: group A (L1, L2, and L3) or group B (L4 and L5). On radiographs, we evaluated contour bulging of the affected pars interarticularis, reactive sclerosis in the contralateral pedicle, anterolisthesis of the involved vertebra, and deviation of the spinous process. On MRI, we assessed pseudoarticulation of the pars interarticularis defect, uneven distribution of posterior epidural fat, the interspinous distance between adjacent segments, facet and disk degeneration in adjacent segments, and other anomalous changes. Among the 63 patients with unilateral spondylolysis, the upper lumbar segment was involved in 29 and the lower lumbar segment, in 34. Group A often displayed contour bulging of the affected pars interarticularis, reactive sclerosis of the contralateral pedicle, and contralateral deviation of the spinous process, all of which were easily detectable on radiography. Group B frequently showed anterolisthesis, pseudoarticulation of the pars interarticularis defect, adjacent facet-disk degeneration, and other anomalous changes that were well observed on MRI. Unilateral lumbar spondylolysis displayed radiologic differences in morphology of the isthmic defect itself and in ancillary findings of the adjacent structures based on the segment involved. Recognition of different ancillary features of unilateral spondylolysis with the use of a feasible diagnostic tool can be helpful for the diagnosis of cases in which a direct sign of isthmic defect is equivocal.

  19. Frequency of asymptomatic pulmonary emboli (PE) in patients with a proximal profound veinal thrombosis (PVT) of inferior limbs during the FRAXODI study; Frequence de l`embolie pulmonaire (EP) asymptomatique chez les malades ayant une thrombose veineuse profonde proximale (TVP) des members inferieurs au cours de l`etude FRAXODI

    Energy Technology Data Exchange (ETDEWEB)

    Gauthier, H.; Rosso, J. [CHU Henri Mondor-Creteil (France); Charbonnier, B. [CHU Trousseau-Tours (France); Meignan, M. [CHU Henri Mondor-Creteil (France)

    1997-12-31

    FRAXODI, an European multi-center program (n=70), allowed to compare the efficiency of Fraxiparin (20 500 UI AXa/mL) once a day with the conventional treatment by Fraxiparin (10 250 UI AXa/mL) twice a day by sub-cutaneous injection in patients with a PVT of inferior limbs without clinical signs of PE. A pulmonary scintigraphy has been performed at registration in 622 patients (delay {<=} 48 h): a sole perfusion with at least 4 incidences of which 2 were posterior oblique incidences or coupled to a ventilation scintigraphy (Xe-133, Kr-81 or aerosols) in 379 patients. Three diagnostic categories were defined: no PE in case of normal examination or under-segmentary perfusion anomalies ({<=} 3); high probability (HP) of PE if at least a defect of normally ventilated segmentary perfusion existed; non-contributing examination in all the other cases. On the ensemble of the group, 367 patients have had at least a defect of segmentary perfusion, 296 patients had two or more. One hundred and forty one patients have had solely defects of sub-segmentary perfusion; 77 patients have had 3 or less then 3. One hundred and fourteen patients have had a normal examination. In the sub-group of ventilation scintigraphy, 235 patients have had at least one defect of segmentary perfusion, 88 patients have had defects of sub-segmentary perfusion and 56 patients have had a normal examination. The diagnosis analysis showed that 42% of patients have had a HP scintigraphy, 30% a non-contributive scintigraphy and the PE could be eliminated in 27% of patients. These results: 1 - demonstrated the extreme frequency of HP aspects of PE in patients afflicted with PVT; 2 - allowed estimating in this patients, as a function of the results of the PIOPED study, the frequency of asymptomatic PE in more then 50%; 3 - allowed recommending in the systematic practice a perfusion scintigraphy in case of PVT without clinical signs of PE providing the over-estimation of secondary PE occurrence during the

  20. Frequency of asymptomatic pulmonary emboli (PE) in patients with a proximal profound veinal thrombosis (PVT) of inferior limbs during the FRAXODI study

    International Nuclear Information System (INIS)

    Gauthier, H.; Rosso, J.; Charbonnier, B.; Meignan, M.

    1997-01-01

    FRAXODI, an European multi-center program (n=70), allowed to compare the efficiency of Fraxiparin (20 500 UI AXa/mL) once a day with the conventional treatment by Fraxiparin (10 250 UI AXa/mL) twice a day by sub-cutaneous injection in patients with a PVT of inferior limbs without clinical signs of PE. A pulmonary scintigraphy has been performed at registration in 622 patients (delay ≤ 48 h): a sole perfusion with at least 4 incidences of which 2 were posterior oblique incidences or coupled to a ventilation scintigraphy (Xe-133, Kr-81 or aerosols) in 379 patients. Three diagnostic categories were defined: no PE in case of normal examination or under-segmentary perfusion anomalies (≤ 3); high probability (HP) of PE if at least a defect of normally ventilated segmentary perfusion existed; non-contributing examination in all the other cases. On the ensemble of the group, 367 patients have had at least a defect of segmentary perfusion, 296 patients had two or more. One hundred and forty one patients have had solely defects of sub-segmentary perfusion; 77 patients have had 3 or less then 3. One hundred and fourteen patients have had a normal examination. In the sub-group of ventilation scintigraphy, 235 patients have had at least one defect of segmentary perfusion, 88 patients have had defects of sub-segmentary perfusion and 56 patients have had a normal examination. The diagnosis analysis showed that 42% of patients have had a HP scintigraphy, 30% a non-contributive scintigraphy and the PE could be eliminated in 27% of patients. These results: 1 - demonstrated the extreme frequency of HP aspects of PE in patients afflicted with PVT; 2 - allowed estimating in this patients, as a function of the results of the PIOPED study, the frequency of asymptomatic PE in more then 50%; 3 - allowed recommending in the systematic practice a perfusion scintigraphy in case of PVT without clinical signs of PE providing the over-estimation of secondary PE occurrence during the

  1. Role of myocardial perfusion imaging in acute coronary syndrome

    International Nuclear Information System (INIS)

    Aleem, M.

    2007-01-01

    Full text: In the cardiac emergency department, a number of patients present with acute chest pain. In case of non diagnostic ECG and enzymes, accurately categorizing the patient in high and low probability is difficult. Aim of study was to evaluate the role of resting myocardial perfusion imaging (MPI) in patients with acute coronary syndrome (ACS) and then to compare the results with subsequent stress imaging. Material and Methods. A total of 34 patients were selected for the study, which were divided into three groups on the basis of respective probabilities of having ACS. This probability was decided on the basis of nature of chest pain, ECG findings, enzymes levels, and age and sex. Arbitrary score was given to patient's condition. This score ranged from 1 to 14. Patients with score between 1-6 were assigned low probability, from 7-10 were assigned intermediate probability and patients having score greater than 11 were placed in high probability groups. Patients in the low and intermediate probability groups were injected with Tc 99 m- MIBI within 6 hours of onset of chest pain and were undergone resting myocardial perfusion imaging (MPI) 3 to five hours after injection.. Imaging in high probability group was performed at discharge. Four weeks after the acute event all the patients underwent stress myocardial perfusion imaging. Results: All patients (100%) with low probability of ACS (n=10) showed negative resting scans. On stress MPI two patients (20%) showed new defects. Patient with high probability of ACS (n=12), all were positive 100% on resting MPI. On stress MPI, three showed (25%) no change from rest MPI, while nine patients (75%) showed augmentation of defects and four out of these nine patients (33%) also showed new perfusion defects. Patients with intermediate probability of ACS (n=12), three showed positive rest MPI (25%). On stress MPI out of these three cases, one showed (8%) no change from rest MPI and two showed (17%) augmentation of defect

  2. Radiographic and radionuclide lung perfusion imaging in healthy calves and calves naturally infected with bovine respiratory syncytial virus

    International Nuclear Information System (INIS)

    Verhoeff, J.; Brom, W.E. van den; Ingh, T.S.G.A.M. van den

    1992-01-01

    Nine calves between three and 18 weeks old with serologically confirmed natural bovine respiratory syncytial virus infection were examined clinically, radiographically and by radionuclide lung perfusion imaging. The results were compared with those from seven healthy calves. The diseased calves were euthanased and examined pathologically, virologically and bacteriologically. The clinical signs indicated that the disease was in an acute stage. Radiography of the diseased animals revealed cysts, corresponding morphologically with bullous emphysema, and infiltrations roughly corresponding in distribution with atelectatic and, or, pneumonic areas. Radionuclide lung perfusion imaging revealed no perfusion shifts between the left and right lungs and a normal perfusion pattern in five of the nine diseased calves. The abnormalities in the perfusion patterns of three calves were probably caused by anatomical disorders such as cysts and pleural adhesions, but no cause of the abnormality could be found in one calf. These findings suggest that in calves infected with bovine respiratory syncytial virus, the normal perfusion pattern is maintained until anatomical disorders occur. The pathological examination and radiography revealed that the cranioventral lung fields were particularly poorly ventilated. This finding and the normal perfusion pattern indicate that these parts of the lungs are probably the sites where shuntings and perfusion-ventilation mismatchings occur

  3. Evaluation of myocardial involvement in Duchenne's progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Sotobata, Iwao; Okada, Mitsuhiro

    1985-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. A qualitative analysis was performed from five projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in the LV posterolateral or posterior wall (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle involvements or thoracic deformities assessed by transmission computed tomography. Extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. Progression of the myocardial scintigraphic abnormalities were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies over 2 to 3 years. It was concluded that thallium myocardial perfusion imaging is a useful clinical technique to assess myocardial involvement in Duchenne's progressive muscular dystrophy. (author)

  4. Evaluation of renal transplant perfusion by functional imaging

    International Nuclear Information System (INIS)

    Nicoletti, R.

    1990-01-01

    Radionuclide angiography (RNA) is used as a noninvasive method for the evaluation of renal transplant perfusion. The computer processing method generally used, based on regions of interest, is unsatisfactory because it does not permit the regional differentiation of perfusion defects. Furthermore, the subjective delineation of the regions of interest introduces considerable inter-observer variation of results. We developed a processing method which is less operator-dependent and permits the evaluation of local defects; it is based on the concept of functional imaging. The method was evaluated in 62 patient examinations, which were subdivided into four groups: Normal transplant perfusion (23 examinations), acute tubular necrose (ATN) (16), cellular rejection (13), and vascular rejection (10). Quantitative results derived from profile curves were combined with visual estimation of the functional images and yielded a synoptic graph which allowed differentiation into three groups: Normal transplant perfusion (sensitivity 0.78, specificity 0.97), ATN or cellular rejection (sens. 0.83, spec. 0.82), and vascular rejection (sens. 0.90, spec. 0.92). (orig.)

  5. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    International Nuclear Information System (INIS)

    Padua, Rodrigo Donizete Santana de; Oliveira, Lucas Ferrari de; Marques, Paulo Mazzoncini de Azevedo; Groote, Jean-Jacques Georges Soares de; Castro, Adelson Antonio de; Ana, Lauro Wichert; Simoes, Marcus Vinicius

    2008-01-01

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  6. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Padua, Rodrigo Donizete Santana de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Div. de Cardiologia]. E-mail: rodrigo_dsp@hcrp.fmrp.usp.br; Oliveira, Lucas Ferrari de [Universidade Federal de Pelotas (UFPel), RS (Brazil). Inst. de Fisica e Matematica. Dept. de Tecnologia da Informacao; Marques, Paulo Mazzoncini de Azevedo [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Groote, Jean-Jacques Georges Soares de [Instituto de Ensino Superior COC, Ribeirao Preto, SP (Brazil). Lab. of Artifical Intelligence and Applications; Castro, Adelson Antonio de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina; Ana, Lauro Wichert [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Simoes, Marcus Vinicius [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina. Divisao de Cardiologia

    2008-11-15

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  7. Changes in perfusion scintigraphy in the first days of heparin therapy in patients with acute pulmonary embolism

    NARCIS (Netherlands)

    de Groot, M. R.; Oostdijk, A. H.; Engelage, A. H.; van Marwijk Kooy, M.; Büller, H. R.

    2000-01-01

    Patients with suspected pulmonary embolism often receive heparin therapy for hours to days before ventilation/perfusion scintigraphy is completed. We assessed to what extent the lung scan classification and pulmonary vascular perfusion changed over a period of 2-4 days of full anticoagulant therapy.

  8. Simultaneous assessment of myocardial perfusion and function during mental stress in patients with chronic coronary artery disease.

    Science.gov (United States)

    Arrighi, James A; Burg, Matthew; Cohen, Ira S; Soufer, Robert

    2003-01-01

    Mental stress (MS) is an important provocateur of myocardial ischemia in many patients with chronic coronary artery disease. The majority of laboratory assessments of ischemia in response to MS have included measurements of either myocardial perfusion or function alone. We performed this study to determine the relationship between alterations in perfusion and ventricular function during MS. Methods and results Twenty-eight patients with reversible perfusion defects on exercise or pharmacologic stress myocardial perfusion imaging (MPI) underwent simultaneous technetium 99m sestamibi single photon emission computed tomography (SPECT) MPI and transthoracic echocardiography at rest and during MS according to a mental arithmetic protocol. In all cases the MS study was performed within 4 weeks of the initial exercise or pharmacologic MPI that demonstrated ischemia. SPECT studies were analyzed visually with the use of a 13-segment model and quantitatively by semiautomated circumferential profile analysis. Echocardiograms were graded on a segmental model for regional wall motion on a 4-point scale. Of 28 patients, 18 (64%) had perfusion defects and/or left ventricular dysfunction develop during MS: 9 (32%) had myocardial perfusion defects develop, 6 (21%) had regional or global left ventricular dysfunction develop, and 3 (11%) had both perfusion defects and left ventricular dysfunction develop. The overall concordance between perfusion and function criteria for ischemia during MS was only 46%. Among 9 patients with MS-induced left ventricular dysfunction, 5 had new regional wall motion abnormalities and 4 had a global decrement in function. In patients with MS-induced ischemia by SPECT, the number of reversible perfusion defects was similar during both MS and exercise/pharmacologic stress (2.8 +/- 2.0 vs 3.5 +/- 1.8, P =.41). Hemodynamic changes during MS were similar whether patients were divided on the basis of perfusion defects or left ventricular dysfunction during MS

  9. Role of myocardial perfusion SPECT in asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Cho, I.; Chun, K.; Won, K.; Lee, H.; Park, J.; Shin, D.; Kim, Y.; Shim, B.; Lee, J.

    2002-01-01

    Purpose: It is important that early diagnosis and treatment of coronary artery disease in diabetic patients, but there are few reports on the prevalence of stress-induced myocardial perfusion abnormalities and the rates of cardiac event in patients with type 2 diabetes. We evaluated the scan findings on gated myocardial perfusion SPECT in asymptomatic diabetic patients. Methods: We performed pharmacological stress test and gated perfusion SPECT in 69 diabetic patients without cardiovascular symptom (mean age: 65 year, male 31 and female 38). Patients underwent two-day imaging protocol and stress study was performed injection of Tc-99m MIBI during adenosine infusion. We followed up these patients by reviewing medical records. Results: Fifty-two of 69 patients (74.5%) showed normal scan findings and 17 patients (24.6%) showed reversible or fixed perfusion defects. Three of 52 patients with normal scan findings showed decreased LV ejection fraction and decreased wall motion. Twenty-three patients with normal scan findings were possible to follow up for more than 1yr (mean time: 18.3±3.3 mo.) and they all had no cardiac event. Three patients with reversible perfusion defects were performed coronary angioplasty. Conclusion: Myocardial perfusion SPECT is a noninvasive method and maybe useful in early diagnosis and predicting prognosis in diabetic patients

  10. In vivo MR perfusion imaging of renal artery stenosis

    International Nuclear Information System (INIS)

    Powers, T.; Lorenz, C.H.; Bain, R.; Holburn, G.; Price, R.R.

    1989-01-01

    Various techniques have been developed for noninvasive evaluation of renal blood flow. More important in the assessment of potential renal ischemia may be actual perfusion of the nephron mass. MR pulse sequences have been devised that allow perfusion imaging (PI) in a dog model of renal artery stenosis. Unilateral renal artery stenosis was created in mongrel dogs and quantitation of renal blood flow was obtained with radioactive microspheres. Perfusion imaging was performed on a 1.5-T system to obtain the apparent diffusion coefficient. During initial studies, it was found that the usual gradient factor used in brain PI was too high for renal studies; a factor of < 50 was found to be optimal. Additionally, respiratory gating with acquisition at end expiration was necessary to prevent renal motion. Recent studies have shown that PI reflects the asymmetry of flow in this model

  11. Impairment of myocardial perfusion in children with sickle cell disease

    International Nuclear Information System (INIS)

    Maunoury, C.; Acar, P.; Montalembert, M. de

    2003-01-01

    While brain, bone and spleen strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Non invasive techniques such as exercise testing and echocardiography have a low sensitivity to detect myocardial ischemia in patients with SCD. We have prospectively assessed myocardial perfusion with Tl-201 SPECT in 23 patients with SCD (10 female, 13 male, mean age 12 ± 5 years). Myocardial SPECT was performed after stress and 3 hours later after reinjection on a single head gamma camera equipped with a LEAP collimator (64 x 64 matrix size format, 30 projections over 180 deg C, 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Myocardial perfusion was impaired in 14/23 patients: 9 reversible defects and 5 fixed defects. The left ventricular cavity was dilated in 14/23 patients. The mean LVEF was 63 ± 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. The frequent impairment of myocardial perfusion in children with SCD could lead to suggest a treatment with hydroxyurea, an improvement of perfusion can be noted with hydroxyurea. (author)

  12. Significance of abnormal myocardial perfusion scintigraphy in young adult patients with SLE

    International Nuclear Information System (INIS)

    Zakavi, S.R.; Kakhki, V.R.D.; Sadeghi, R.; Jokar, M.H.; Khazaei, G.

    2009-01-01

    Detection of subclinical coronary artery disease (CAD) is a potential challenge in patients with systemic lupus erythematosus (SLE) and it is suggested that myocardial perfusion single photon emission computerized tomography (SPECT) is more sensitive than exercise test in this setting. However, the significance of perfusion abnormalities in SLE patients is not well known. In this study, we evaluated the prognostic significance of myocardial perfusion defects in patients with SLE. Patients with proven diagnosis of SLE admitted to the hospital due to noncardiac problems with no history of CAD were studied. All patients underwent 99m Tc-methoxyisobutylisonitrile (MIBI) myocardial perfusion scan using dipyridamole as pharmacological stress. All patients were followed up by reviewing patients file in lupus clinic and any minor or major cardiac events were recorded. Eighteen female and two male patients with mean age of 28.2±12.05 years were included. Six patients had mild reversible perfusion defects with mean summed difference score of 2.5±1.0. Pattern of reverse redistribution (reverse fill-in) was noted in three patients. Eleven patients had normal myocardial perfusion. Hypokinesia was noted in three patients on gated images. One patient with abnormal perfusion died 21 days after imaging due to on-cardiac cause. Nineteen patients were followed for a mean time of 39.2±16.0 months. No major or minor cardiac events were noted during follow-up. Three patients (one with abnormal perfusion) had at least one readmission during follow-up period. Our study showed that myocardial perfusion abnormalities are fairly frequent in SLE patients but the defects are generally mild and do not advocate an adverse prognosis. (author)

  13. Three-dimensional surface display of brain perfusion with 123I-IMP in Parkinson's disease

    International Nuclear Information System (INIS)

    Tachibana, H.; Kawabata, K.; Tomino, Y.; Sugita, M.; Fukuchi, M.

    1994-01-01

    We reconstructed three-dimensional (3D) surface images from single-photon emission computed tomography (SPECT) data using N-isopropyl-p[ 123 I]-iodoamphetamine ( 123 I-IMP) in 27 patients with Parkinson's disease and 11 normal control subjects. The 3D reconstruction was performed using distance-shaded methods at threshold levels with an interval of 5% from 45-80%. Any area of decreased perfusion at each threshold level was visualised as a defect area by the algorithm. In nondemented patients with Parkinson's disease, perfusion defects were frequently found in the parietal cortex at a threshold value of 65%. In demented patients, perfusion defects were frequently seen at thresholds of 45-65%, and were more marked in the temporal and parietal cortex bilaterally. This suggests that dementia in Parkinson's disease is related to a reduction of perfusion in the temporoparietal cortex. (orig.)

  14. Nifedipine and thallium-201 myocardial perfusion in progressive systemic sclerosis

    International Nuclear Information System (INIS)

    Kahan, A.; Devaux, J.Y.; Amor, B.

    1986-01-01

    Heart disease in patients with progressive systemic sclerosis may be due in part to myocardial ischemia caused by a disturbance of the coronary microcirculation. To determine whether abnormalities of myocardial perfusion in this disorder are potentially reversible, we evaluated the effect of the coronary vasodilator nifedipine on myocardial perfusion assessed by thallium-201 scanning in 20 patients. Thallium-201 single-photon-emission computerized tomography was performed under control conditions and 90 minutes after 20 mg of oral nifedipine. The mean (+/- SD) number of left ventricular segments with perfusion defects decreased from 5.3 +/- 2.0 to 3.3 +/- 2.2 after nifedipine (P = 0.0003). Perfusion abnormalities were quantified by a perfusion score (0 to 2.0) assigned to each left ventricular segment and by a global perfusion score (0 to 18) for the entire left ventricle. The mean perfusion score in segments with resting defects increased from 0.97 +/- 0.24 to 1.26 +/- 0.44 after nifedipine (P less than 0.00001). The mean global perfusion score increased from 11.2 +/- 1.7 to 12.8 +/- 2.4 after nifedipine (P = 0.003). The global perfusion score increased by at least 2.0 in 10 patients and decreased by at least 2.0 in only 1. These observations reveal short-term improvement in thallium-201 myocardial perfusion with nifedipine in patients with progressive systemic sclerosis. The results are consistent with a potentially reversible abnormality of coronary vasomotion in this disorder, but the long-term therapeutic effects of nifedipine remain to be determined

  15. Dipyridamole-thallium-201 tomography documenting improved myocardial perfusion with therapy in Kawasaki disease

    International Nuclear Information System (INIS)

    Nienaber, C.A.; Spielmann, R.P.; Hausdorf, G.

    1988-01-01

    Thallium-201 tomographic perfusion studies after pharmacologic vasodilation were performed in seven children (aged 2 years 8 months to 8 years 7 months), 3 to 20 months after the acute stage of the disease. In all patients coronary aneurysms were seen on cross-sectional echocardiograms. The scintigrams of six children showed no significant regional reduction of myocardial thallium-201 uptake. These children had remained asymptomatic in the follow-up period after the acute inflammatory stage of Kawasaki disease. Persistent and transient thallium defects were present in one child with acute posterolateral myocardial infarction; obstruction of two coronary vessels supplying the defect zones was confirmed by contrast angiography. After 8 months of treatment a follow-up nuclear scan showed marked reduction in the size of the defect and almost complete abolishment of the ischemic reaction. Thus tomographic thallium-201 perfusion scintigraphy in conjunction with vasodilation stress is useful to assess myocardial perfusion in children with Kawasaki disease and demonstrates marked improvement in regional perfusion after adequate medical therapy

  16. Computational fluid dynamics in ventilation: Practical approach

    Science.gov (United States)

    Fontaine, J. R.

    The potential of computation fluid dynamics (CFD) for conceiving ventilation systems is shown through the simulation of five practical cases. The following examples are considered: capture of pollutants on a surface treating tank equipped with a unilateral suction slot in the presence of a disturbing air draft opposed to suction; dispersion of solid aerosols inside fume cupboards; performances comparison of two general ventilation systems in a silkscreen printing workshop; ventilation of a large open painting area; and oil fog removal inside a mechanical engineering workshop. Whereas the two first problems are analyzed through two dimensional numerical simulations, the three other cases require three dimensional modeling. For the surface treating tank case, numerical results are compared to laboratory experiment data. All simulations are carried out using EOL, a CFD software specially devised to deal with air quality problems in industrial ventilated premises. It contains many analysis tools to interpret the results in terms familiar to the industrial hygienist. Much experimental work has been engaged to validate the predictions of EOL for ventilation flows.

  17. Acetazolamide stimulation test in patients with unilateral internal carotid artery stenosis using Tc-99m HMPAO SPECT and transcranial doppler sonography

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I. Y.; Na, J. H. [Inha University Hospital, Incheon (Korea, Republic of)

    2007-07-01

    We compared perfusion reserve by acetazolamide (ACZ) challenged brain perfusion SPECT and cerebral vasoreactivity (CVR) by transcranial Doppler sonography (TCD) in patients with unilateral internal carotid artery stenosis. This study was conducted prospectively in 37 consecutive patients with angiographically proven unilateral internal carotid artery stenosis (stenosis> 50%). We estimated % CVR (100? {l_brace}post-ACZ mean velocity (cm/sec) - Pre-ACZ mean velocity (cm/sec){r_brace} / pre-ACZ mean velocity) by TCD. The % CVR was compared with perfusion reserve of SPECT. The % CVR of MCA and ICA was significantly decreased in the ipsilateral side to the carotid stenosis (p<0.05). The CVR impairment was more severe when cerebral infarct is already developed (p<0.01). There was a significant correlation between the degree of carotid stenosis and the CVR (p<0.01). In the area of impaired perfusion reserve on the SPECT, the estimated CVR by TCD was significantly lower (p<0.05), even to the negative value, implying that there is actually steal phenomenon in that area. ACZ challenge can actually decrease cerebral blood flow in the area of impaired perfusion reserve on brain SPECT. So we should be very cautiously performing in ACZ challenge especially when there is a severe carotid stenosis because there is a possibility of developing hemodynamic stroke.

  18. A Short Period of Ventilation without Perfusion Seems to Reduce Atelectasis without Harming the Lungs during Ex Vivo Lung Perfusion

    Directory of Open Access Journals (Sweden)

    Sandra Lindstedt

    2013-01-01

    Full Text Available To evaluate the lung function of donors after circulatory deaths (DCDs, ex vivo lung perfusion (EVLP has been shown to be a valuable method. We present modified EVLP where lung atelectasis is removed, while the lung perfusion is temporarily shut down. Twelve pigs were randomized into two groups: modified EVLP and conventional EVLP. When the lungs had reached 37°C in the EVLP circuit, lung perfusion was temporarily shut down in the modified EVLP group, and positive end-expiratory pressure (PEEP was increased to 10 cm H2O for 10 minutes. In the conventional EVLP group, PEEP was increased to 10 cm H2O for 10 minutes with unchanged lung perfusion. In the modified EVLP group, the arterial oxygen partial pressure (PaO2 was 18.5 ± 7.0 kPa before and 64.5 ± 6.0 kPa after the maneuver (P<0.001. In the conventional EVLP group, the PaO2 was 16.8 ± 3.1 kPa and 46.8 ± 2.7 kPa after the maneuver (P<0.01; P<0.01. In the modified EVLP group, the pulmonary graft weight was unchanged, while in the conventional EVLP group, the pulmonary graft weight was significantly increased. Modified EVLP with normoventilation of the lungs without ongoing lung perfusion for 10 minutes may eliminate atelectasis almost completely without harming the lungs.

  19. Myocardial perfusion changes in patients irradiated for left-sided breast cancer and correlation with coronary artery distribution

    International Nuclear Information System (INIS)

    Lind, Pehr A.; Pagnanelli, Robert; Marks, Lawrence B.; Borges-Neto, Salvador; Hu, Caroline; Zhou, S.-M.; Light, Kim; Hardenbergh, Patricia H.

    2003-01-01

    Purpose: To evaluate postradiation regional heart perfusion changes with single photon emission tomography (SPECT) myocardial perfusion imaging in 69 patients treated with tangential photon beams radiation therapy (RT) for left-sided breast cancer. To correlate SPECT changes with percent irradiated left ventricle (LV) volume and risk factors for coronary artery disease (CAD). Methods and Materials: Rest SPECT of the LV was acquired pre-RT and at 6-month intervals post-RT. The extent of defects (%) with a severity > 1.5 standard deviations below the mean was quantitatively analyzed for the distributions of the left anterior descending (LAD) artery, left circumflex (LCX) artery, and right coronary artery (RCA) based on computer assisted polar map reconstruction (i.e., bull's-eye-view). Changes in perfusion were correlated with percent irradiated LV receiving > 25 Gy (range 0-32%). Data on patient- and treatment-related factors were collected prospectively (e.g., cardiac premorbidity, risk factors for CAD, chemotherapy, and hormonal treatment). Results: In the LAD distribution, there were increased perfusion defects at 6 months (median 11%; interquartile range 2-23) compared with baseline (median 5%; interquartile range 1-14) (p<0.001). There were no increases in perfusion defects in the LCX or RCA distributions. In multivariate analysis, the SPECT perfusion changes in the LAD distribution at 6 months were independently associated with percent irradiated LV (p<0.001), hormonal therapy (p=0.005), and pre-RT hypercholesterolemia (p=0.006). The SPECT defects in the LAD distribution at 12 and 18 months were not statistically different from those at 6 months. The perfusion defects in the LAD distribution were limited essentially to the regions of irradiated myocardium. Conclusion: Tangential photon beam RT in patients with left-sided breast cancer was associated with short-term SPECT defects in the vascular distribution corresponding to the radiation portals. Factors

  20. Primair sarcoom van de A. pulmonalis : zeldzame oorzaak van cor pulmonale

    NARCIS (Netherlands)

    Ismaël, F; van der Werf, T S; de Boer, W J; Timens, W; Nossent, G D; Ligtenberg, J J

    1999-01-01

    A 64-year-old female presented with fever and weight loss, accompanied by normochromic normocytic anaemia with high erythrocyte sedimentation rate. She developed severe cor pulmonale. Ventilation-perfusion scintigraphy revealed a non-matched perfusion defect of the entire right lung with impaired

  1. Accuracy and feasibility of dynamic contrast-enhanced 3D MR imaging in the assessment of lung perfusion: comparison with Tc-99 MAA perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yilmaz, E.; Akkoclu, A.; Degirmenci, B.; Cooper, R.A.; Sengun, B.; Gulcu, A.; Osma, E.; Ucan, E.S.

    2005-01-01

    AIM: The aim of this study was to correlate findings of perfusion magnetic resonance imaging (MRI) and perfusion scintigraphy in cases where there was a suspicion of abnormal pulmonary vasculature, and to evaluate the usefulness of MRI in the detection of perfusion deficits of the lung. METHODS: In all, 17 patients with suspected abnormality of the pulmonary vasculature underwent dynamic contrast-enhanced MRI. T1-weighted 3D fast-field echo pulse sequences were obtained (TR/TE 3.3/1.58 ms; flip angle 30 deg ; slice thickness 12 to 15 mm). The dynamic study was acquired in the coronal plane following administration of 0.1 mmol/kg gadopentetate dimeglumine. A total of 8 to 10 sections repeated 20 to 25 times at intervals of 1 s were performed. Perfusion lung scintigraphy was carried out a maximum of 48 h before the MR examination in all cases. Two radiologists, who were blinded to the clinical data and results of other imaging methods, reviewed all coronal sections. MR perfusion images were independently assessed in terms of segmental or lobar perfusion defects in the 85 lobes of the 17 individuals, and the findings were compared with the results of scintigraphy. RESULTS: Of the 17 patients, 8 were found to have pulmonary emboli, 2 chronic obstructive pulmonary disease with emphysema, 2 bullous emphysema, 2 Takayasu arteritis and 1 had a hypoplastic pulmonary artery. Pulmonary perfusion was completely normal in 2 cases. In 35 lobes, perfusion defects were detected using both methods, in 4 with MR alone and in 9 only with scintigraphy. There was good agreement between MRI and scintigraphy findings (kappa=0.695). CONCLUSION: Pulmonary perfusion MRI is a new alternative to scintigraphy in the evaluation of pulmonary perfusion for various lung disorders. In addition, this technique allows measurement and quantification of pulmonary perfusion abnormalities

  2. Three-dimensional surface display of brain perfusion with [sup 123]I-IMP in Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Tachibana, H [Fifth Dept. of Internal Medicine, Hyogo Coll. of Medicine, Nishinomiya (Japan); Kawabata, K [Fifth Dept. of Internal Medicine, Hyogo Coll. of Medicine, Nishinomiya (Japan); Tomino, Y [Fifth Dept. of Internal Medicine, Hyogo Coll. of Medicine, Nishinomiya (Japan); Sugita, M [Fifth Dept. of Internal Medicine, Hyogo Coll. of Medicine, Nishinomiya (Japan); Fukuchi, M [Dept. of Nuclear Medicine, Hyogo Coll. of Medicine, Nishinomiya (Japan)

    1994-05-01

    We reconstructed three-dimensional (3D) surface images from single-photon emission computed tomography (SPECT) data using N-isopropyl-p[[sup 123]I]-iodoamphetamine ([sup 123]I-IMP) in 27 patients with Parkinson's disease and 11 normal control subjects. The 3D reconstruction was performed using distance-shaded methods at threshold levels with an interval of 5% from 45-80%. Any area of decreased perfusion at each threshold level was visualised as a defect area by the algorithm. In nondemented patients with Parkinson's disease, perfusion defects were frequently found in the parietal cortex at a threshold value of 65%. In demented patients, perfusion defects were frequently seen at thresholds of 45-65%, and were more marked in the temporal and parietal cortex bilaterally. This suggests that dementia in Parkinson's disease is related to a reduction of perfusion in the temporoparietal cortex. (orig.)

  3. Fabrication and perfusion culture of anatomically shaped artificial bone using stereolithography

    International Nuclear Information System (INIS)

    Du, Dajiang; Asaoka, Teruo; Ushida, Takashi; Furukawa, Katsuko S

    2014-01-01

    Because patient bone defects are usually varied and complicated in geometry, it would be preferred to fabricate custom-made artificial bone grafts that are anatomically specific to individual patient defects. Using a rabbit femoral segment as a bone reconstruction model, we successfully produced customized ceramic scaffolds by stereolithography, which not only had an anatomically correct external shape according to computed tomography data but also contained an interconnecting internal network of channels designed for perfusion culture. Rabbit bone marrow stromal cells were isolated and cultured with these scaffolds using a novel oscillatory perfusion system that was stereolithographically fabricated to fit well to the unique scaffold shapes. After five days of three-dimensional culture with oscillatory perfusion, the cells attached and proliferated homogenously in the scaffolds. However, control cells inside the scaffolds cultured under static conditions were dead after prolonged in vitro culture. Cellular DNA content and alkaline phosphatase activities were significantly higher in the perfusion group versus the static group. Therefore, anatomically correct artificial bone can be successfully constructed using stereolithography and oscillatory culture technology, and could be useful for bone engraftment and defect repair. (paper)

  4. Regional measurement of ventilation and perfusion to detect subtle lung abnormalities in coal miners

    International Nuclear Information System (INIS)

    Susskind, H.; Liu, J.; Brill, A.B.

    1986-01-01

    The relationship between regional pulmonary ventilation (V) and perfusion (Q) uniquely determines the amount of gas exchange that occurs in the lungs. Therefore, the pixel-by-pixel distributions of V and Q were measured with continuously inhaled Kr-81m and i.v. injected Tc-99m MAA, respectively, in a group of 71 subjects exposed to coal dust and then compared with those from a control group of 9 healthy volunteers. Each subject sat upright with his back against a large-field-of-view scintillation camera; 500,000 count images were obtained, analyzed by computer, and then displayed in a 64 x 64 matrix. Individual pixel values of V and Q were correlated by a best-fit regression line, whose slope was proportional to the overall V/Q ratio. The slopes of individual groups of nonsmokers, ex-smokers, and smokers (0.83-0.85) were significantly greater (p < 0.02) than the slope of the controls (0.70 +/- 0.07). In addition, the authors found that the skewness of plots of frequency distribution of V/Q and of V and Q vs V/Q for the individual patient groups was statistically different from that of the normals (p < 0.01). Statistical analysis of local and Q values therefore appears to be a potentially useful, non-invasive method to evaluate subtle regional lung impairment

  5. Myocardial perfusion in patients with left bundle branch block and without coronary artery disease

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru

    1992-01-01

    For the evaluation of myocardial perfusion in patients with left bundle branch block (LBBB), we performed exercise stress (Ex)-redistribution (RD) myocardial tomography with thallium-201 ( 201 Tl) in 23 patients with LBBB and without coronary artery disease (CAD). Myocardial images in patients with LBBB were compared with those of 9 patients with CAD who showed Ex induced transient septal defect. Bull'-eye maps ( 201 Tl distribution maps at Ex and RD and 201 Tl washout rate [WOR] map) were made from myocardial tomograms. In 23 patients with LBBB, 15 patients (65%) developed myocardial perfusion abnormality. In 10 (67%) of these 15 patients, transient perfusion defect appeared in the entire septum (diffuse type). On the other hand in 5 patients (33%), localized fixed perfusion defect developed at the boundary between septum and anterior wall (focal type). In focal type, every patient had other disease such as hypertension, aortic stenosis or sick sinus syndrome. While in patients with diffuse type, other diseases were observed in 30% (p 201 Tl WOR and 201 Tl uptake ratio of septum to lateral wall indicated that exercise induced septal defect was slighter in diffuse type than CAD. These points might be useful to differentiate whether CAD participates in the septal defect or not in patients with LBBB. (author)

  6. Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

    Science.gov (United States)

    Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin H; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F

    2015-07-01

    To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.

  7. Pulmonary ventilation studies of asthmatic children with Kr-81m

    International Nuclear Information System (INIS)

    Uchiyama, Guio; Hotta, Toshiko; Arimizu, Noboru; Sugimoto, Kazuo.

    1979-01-01

    Krypton-81 m gas was eluted from the 81 Rb-sup(81m)Kr generator by using compressed air or oxygen as an eluting agent. The continuous inhalation of mixed gas of sup(81m)Kr and air or oxygen with the use of a scintillation camera produced a pulmonary image of which density was proportional to regional ventilation. Because of short half life of sup(81m)Kr (13 seconds), exhaled gas was not necessary to be trapped by the charcoal filter, and the several pulmonary views of a patient could readily be available in a short period of time. The great advantage of sup(81m)Kr generator was found in use for the studies of small children who were not usually cooperative to medical examination. Thirty seven patients with bronchial asthma of any state were so far studied. Their ages ranged from 3 to 15 years old. Studies revealed the definite ventilation defects in scans of patients with asthmatic attack. Re-scans right after the use of bronchodilators showed marked improvement of the ventilation defects. Exercise-induced asthma (EIA) was easily identified by the sup(81m)Kr ventilation study. After premedications for EIA with disodium cromoglicate, the next exercises produced less or no ventilation defects, and the preventive effect could be individually examined. The sup(81m)Kr ventilation study was also used for estimating the patient's sensitivity to provokative substances of bronchial asthma. House dust was continuously inhaled with sup(81m)Kr gas by patients. The threshold dose of house dust of disclosing ventilation defects in scans was definitely less than that of provokating the symptom of asthmatic attack. The sensitive sup(81m)Kr ventilation study could be another provokative test which induces no clinical symptoms. (author)

  8. Pulmonary ventilation studies of asthmatic children with Kr-81m

    Energy Technology Data Exchange (ETDEWEB)

    Uchiyama, G; Hotta, T; Arimizu, N [Chiba Univ. (Japan). School of Medicine; Sugimoto, K

    1979-05-01

    Krypton-81 m gas was eluted from the /sup 81/Rb-sup(81m)Kr generator by using compressed air or oxygen as an eluting agent. The continuous inhalation of mixed gas of sup(81m)Kr and air or oxygen with the use of a scintillation camera produced a pulmonary image of which density was proportional to regional ventilation. Because of short half life of sup(81m)Kr (13 seconds), exhaled gas was not necessary to be trapped by the charcoal filter, and the several pulmonary views of a patient could readily be available in a short period of time. The great advantage of sup(81m)Kr generator was found in use for the studies of small children who were not usually cooperative to medical examination. Thirty seven patients with bronchial asthma of any state were so far studied. Their ages ranged from 3 to 15 years old. Studies revealed the definite ventilation defects in scans of patients with asthmatic attack. Re-scans right after the use of bronchodilators showed marked improvement of the ventilation defects. Exercise-induced asthma (EIA) was easily identified by the sup(81m)Kr ventilation study. After premedications for EIA with disodium cromoglicate, the next exercises produced less or no ventilation defects, and the preventive effect could be individually examined. The sup(81m)Kr ventilation study was also used for estimating the patient's sensitivity to provokative substances of bronchial asthma. House dust was continuously inhaled with sup(81m)Kr gas by patients. The threshold dose of house dust of disclosing ventilation defects in scans was definitely less than that of provokating the symptom of asthmatic attack. The sensitive sup(81m)Kr ventilation study could be another provokative test which induces no clinical symptoms. (author).

  9. Successful 1:1 proportion ventilation with a unique device for independent lung ventilation using a double-lumen tube without complications in the supine and lateral decubitus positions. A pilot study.

    Directory of Open Access Journals (Sweden)

    Michał Kowalczyk

    Full Text Available Adequate blood oxygenation and ventilation/perfusion matching should be main goal of anaesthetic and intensive care management. At present, one of the methods of improving gas exchange restricted by ventilation/perfusion mismatching is independent ventilation with two ventilators. Recently, however, a unique device has been developed, enabling ventilation of independent lungs in 1:1, 2:1, 3:1, and 5:1 proportions. The main goal of the study was to evaluate the device's utility, precision and impact on pulmonary mechanics. Secondly- to measure the gas distribution in supine and lateral decubitus position.69 patients who underwent elective thoracic surgery were eligible for the study. During general anaesthesia, after double lumen tube intubation, the aforementioned control system was placed between the anaesthetic machine and the patient. In the supine and lateral decubitus (left/right positions, measurements of conventional and independent (1:1 proportion ventilation were performed separately for each lung, including the following: tidal volume, peak pressure and dynamic compliance.Our results show that conventional ventilation using Robertshaw tube in the supine position directs 47% of the tidal volume to the left lung and 53% to the right lung. Furthermore, in the left lateral position, 44% is directed to the dependent lung and 56% to the non-dependent lung. In the right lateral position, 49% is directed to the dependent lung and 51% to the non-dependent lung. The control system positively affected non-dependent and dependent lung ventilation by delivering equal tidal volumes into both lungs with no adverse effects, regardless of patient's position.We report that gas distribution is uneven during conventional ventilation using Robertshaw tube in the supine and lateral decubitus positions. However, this recently released control system enables precise and safe independent ventilation in the supine and the left and right lateral decubitus

  10. Assessment of relationship between regional perfusion and ventricular function in patients with severely depressed ejection fraction

    International Nuclear Information System (INIS)

    Teresinska, A.; Konieczna, S.; Szumilak, B.; Gosiewska-Marcinkowska, E.; Potocka, J.

    1998-01-01

    Patients with low ventricular (LV) ejection fraction (EF) and with regional or global LV dysfunction, considered for myocardial revascularization, are often submitted to myocardial perfusion study to ptrove perfusion preserved and to approximate viability. The aim of this work is to evaluate, to what extent SPECT with Tc-99m-MIBI (SPECT-MIBI) additionally differentiatesa and enlarges the information on LV contractility achieved from radioisotopic ventriculography (RNV). Seventy-three patients with EF=0.11-0.35 (mean: 0.26 ± 0.06, calculated from RNV) were studied. Planar gated RNV and SPECT-MIBI were performed within 2 months (mean: 15 ± 14 days). RNV, after in vivo red cells labeling with Tc-99m, was recorded in rest in LAO45 and RAO30 views. Global EF and contractility of 5 regions (anterior, posterior, lateral walls, septum and apex) were evaluated. Assessment was performed by means of LV in 'cine' mode,m ED and ES outlines and amplitude-phase images. Regional contractility abnormalities were classified as dyskinesis, akinesis and hypokinesis. SPECT-MIBI was performed in rest and stress. Perfusion abnormalities in 5 above mentioned regions was classified as large (more intense than 50% of myocardial maximum) or small persistent defects (DEFpers), large or small partially reversible defects (DEFpart-rev), large or small completely reversible defects (DEFrev). Hypokinesis was detected in 23-35 regions (65%) , dyskinesis - in 63 (17%), akinesis - in 37 (10%), normokinesis - in 27 (7%). In dyskinetic regions, there existed large DEFpers (79%) or large DEFpart-rev (21%). In akinetic regions, there also existed large DEFpers (68%) or large DEFpart-rev (32%). In hypokinetic regions, there were no perfusion defects (31% of regions), small DEFpers, DEFrev and DEFpart-rev (42%) and also large DEFpers (27%). In most of normokinetic regions, different types of perfusion defects were observed (large DEFpers existed in 26% of regions). In summary: In dyskinetic and akinetic

  11. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro

    1983-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy. (author)

  12. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro (Nagoya Univ. (Japan). Faculty of Medicine)

    1983-12-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy.

  13. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Weininger, Markus [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Ramachandra, Ashok [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Rowe, Garrett W.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Henzler, Thomas [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

    2012-12-15

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  14. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    International Nuclear Information System (INIS)

    Weininger, Markus; Schoepf, U. Joseph; Ramachandra, Ashok; Fink, Christian; Rowe, Garrett W.; Costello, Philip; Henzler, Thomas

    2012-01-01

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  15. The value of right lateral decubitus position to decrease artificial defect of cardiac anterior wall in 99Tcm-MIBI SPECT myocardial perfusion imaging for women

    International Nuclear Information System (INIS)

    Huang Kemin; Feng Yanlin; Wen Guanghua; Liang Weitang; Yu Fengwen; Liu Dejun

    2013-01-01

    Objective: To explore the value of right lateral decubitus position MPI for differentiating myocardial perfusion defect from cardiac anterior wall attenuation artificial defect, caused by breast of woman. Methods: Forty-nine patients(average age (61.5±8.4) years) who had low likelihood of coronary artery disease and had perfusion defect in the anterior wall after exercise stress 99 Tc m -MIBI MPI were included. All underwent supine and right lateral decubitus position during resting SPECT images. The myocardial perfusion SPECT images at left ventricle were reconstructed and were measured by Bull's-eye, based on the counts. Results from both supine position imaging and right lateral decubitus position imaging were compared. Paired t test was used to statistically analyse the data by SPSS 13.0. Results: Compared with supine position, the counts of the anterior, inferior, apex and lateral wall in right lateral decubitus position were significantly higher: (71.30±3.53)% vs (66.50±3.85)%, (70.06±4.45)% vs (65.44±4.16)%, (77.90±3.00)% vs (75.81±4.08)%,(79.30±2.26)% vs (72.60±3.87)% (t=6.731, 5.286, 3.555, 10.885, all P<0.01). The counts of septal wall were significantly lower ((66.60±3.98)% vs (70.06±4.51)%, t=-4.625, P<0.01) in right lateral decubitus position than that in supine position. Among the different regions of anterior wall, the counts of the anterior-middle ((76.40 ± 3.80)% vs (68.60 ± 4.76)%) and anterior-apex region ((77.10±3.24)% vs (69.00±3.54)%) were significantly higher (t=9.916, 8.870, both P<0.01) in right lateral decubitus position than those in supine position, but there was insignificance ((56.94±6.06)% vs (58.50±4.98)%, t=-1.493, P>0.05) at anterior-basal region. The artificial defect of different degrees in anterior wall was observed in all patients in supine position, 23 cases (46.9%, 23/49) showed artificial defect in the anterior-middle region and 16 cases (32.7%, 16/49) in the anterior-apex region. All artificial defect

  16. Detection of misery perfusion in the cerebral hemisphere with chronic unilateral major cerebral artery steno-occlusive disease using crossed cerebellar hypoperfusion: comparison of brain SPECT and PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Yoshiyasu; Ogasawara, Kuniaki; Saito, Hideo; Takahashi, Yoshihiro; Ogasawara, Yasushi; Kobayashi, Masakazu; Ogawa, Akira [Iwate Medical University, Department of Neurosurgery, Morioka (Japan); Iwate Medical University, Cyclotron Research Center, Morioka (Japan); Terasaki, Kazunori [Iwate Medical University, Cyclotron Research Center, Morioka (Japan); Yoshida, Kenji; Beppu, Takaaki; Kubo, Yoshitaka; Fujiwara, Shunrou [Iwate Medical University, Department of Neurosurgery, Morioka (Japan); Tsushima, Eiki [Hirosaki University, Graduate School of Health Sciences, Hirosaki (Japan)

    2013-10-15

    In patients with unilateral internal carotid or middle cerebral artery (ICA or MCA) occlusive disease, the degree of crossed cerebellar hypoperfusion that is evident within a few months after the onset of stroke may reflect cerebral metabolic rate of oxygen in the affected cerebral hemisphere relative to that in the contralateral cerebral hemisphere. The aim of the present study was to determine whether the ratio of blood flow asymmetry in the cerebellar hemisphere to blood flow asymmetry in the cerebral hemisphere on positron emission tomography (PET) and single photon emission computed tomography (SPECT) correlates with oxygen extraction fraction (OEF) asymmetry in the cerebral hemisphere on PET in patients with chronic unilateral ICA or MCA occlusive disease and whether this blood flow ratio on SPECT detects misery perfusion in the affected cerebral hemisphere in such patients. Brain blood flow and OEF were assessed using {sup 15}O-PET and N-isopropyl-p-[{sup 123}I]iodoamphetamine ({sup 123}I-IMP) SPECT, respectively. All images were anatomically standardized using SPM2. A region of interest (ROI) was automatically placed in the bilateral MCA territories and in the bilateral cerebellar hemispheres using a three-dimensional stereotaxic ROI template, and affected-to-contralateral asymmetry in the MCA territory or contralateral-to-affected asymmetry in the cerebellar hemisphere was calculated. Sixty-three patients with reduced blood flow in the affected cerebral hemisphere on {sup 123}I-IMP SPECT were enrolled in this study. A significant correlation was observed between MCA ROI asymmetry of PET OEF and the ratio of cerebellar hemisphere asymmetry of blood flow to MCA ROI asymmetry of blood flow on PET (r = 0.381, p = 0.0019) or SPECT (r = 0.459, p = 0.0001). The correlation coefficient was higher when reanalyzed in a subgroup of 43 patients undergoing a PET study within 3 months after the last ischemic event (r = 0.541, p = 0.0001 for PET; r = 0.609, p < 0

  17. Assessment of the myocardial perfusion pattern in patients with multivessel coronary artery disease

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Segal, B.L.; Kane, S.A.; Amenta, A.

    1983-01-01

    A total of 42 symptomatic patients with coronary artery disease involving two or three vessels were studied using exercise thallium-201 myocardial scintigraphy. Qualitative analysis of the images predicted multivessel disease in 75% of the patients with two-vessel disease and in 82% of the patients with three-vessel disease. Quantitative analysis of the size of the perfusion defect indicated that approximately 40% of the left ventricular perimeter showed abnormal perfusion pattern during stress in these patients, and there was no significant difference in the size of the defect in patients with two-vessel disease or three-vessel disease (41 +/- 17% vs 42 +/- 14%, respectively, mean +/- SD). The exercise heart rate, exercise ECG response, and severity of narrowing did not correlate with the size of the perfusion defect. Patients with anterior infarction had larger defects in the distribution of the left anterior descending artery than those without infarction. Collaterals offered partial protection during exercise only when they were not jeopardized. This study confirms the value of qualitative analysis of exercise thallium-201 imaging in predicting multivessel disease, and describes a simple method of assessing the extent of perfusion abnormalities during stress in patients with multivessel disease. The results may be important in patient management and prognosis

  18. Correlation of semiquantitative analysis of the distribution of pulmonary perfusion with pulmonary function in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Uchida, Kou; Nakayama, Hiroyuki; Yamagami, Ikue; Takahashi, Hideki; Takano, Masaaki.

    1997-01-01

    We carried out ventilation-perfusion scintigraphy and pulmonary function tests in 56 patients with chronic obstructive pulmonary disease (COPD) and 19 healthy volunteers. We used 99m Tc-macroaggregated albumin for the perfusion scintigraphy and 133 Xe gas for the ventilation scintigraphy. The lung volume image was created by computerized summation of the radioactivity in the rebreathing phase. Regions of interest (ROIs) were set automatically on lung volume image, which included each whole lung, and on perfusion image, including areas with relatively high radioactivity, with cut-off levels of 50%, 70%, and 90%. The number of pixels in each ROI was used as an index of lung volume (L) or perfusion (P). Perfusion per unit of lung volume (P/L) was also used as an index of perfusion. P70 and P70/L showed the better correlations than the other parameters, including significant correlations with vital capacity, FEV 1.0 , peak flow rate, RV/TLC, diffusing capacity and arterial oxygen partial pressure. The significant difference in P70 and P70/L between patients with hypoxemia and those without hypoxemia suggested that P70 and P70/L are useful indicators of the severity of COPD. We conclude that semiquantified values of pulmonary perfusion scintigraphy are significantly correlated with pulmonary function and the severity of COPD. (author)

  19. A comparison of the economics of xenon 127, xenon 133 and krypton 81m for routine ventilation imaging of the lungs

    International Nuclear Information System (INIS)

    Nimmo, M.J.; Merrick, M.V.; Millar, A.M.

    1985-01-01

    The authors have compared the cost of providing routine lung ventilation scintigraphy using 127 Xe with other radioactive gases in 100 patients. The physical properties of 127 Xe permit a logical imaging sequence where a ventilation study is only carried out if indicated by perfusion scintigraphy which is performed first. With 133 Xe, all patients must be ventilated prospectively, or a preselection carried out based on radiographic appearances at the time of imaging. This results in a greater number of ventilation studies than with 127 Xe. Despite the greater cost per study of 127 Xe, the overall cost of providing a routine diagnostic service with this gas is no more than that of using 133 Xe in selected patients. The cost of ventilating all patients prospectively with 133 Xe is considerably greater than using 127 Xe only when indicated by abnormal perfusion images. If ventilation imaging is to be available at all times, either isotope of xenon costs very much less than 81 Krsup(m). It is concluded that 127 Xe is the radiopharmaceutical of choice for routine lung ventilation scintigraphy. (author)

  20. Pulmonary O2 transfer during pulsatile and non-pulsatile perfusion.

    Science.gov (United States)

    Hauge, A; Nicolaysen, G

    1980-07-01

    The importance of the perfusion pattern for the oxygen transfer has been examined in isolated rabbit lungs perfused with plasma at constant volume inflow. The lungs were ventilated with constant tidal volume and constant end-expiratory pressure. Following a standardized rise in FIO2 the rate of rise in pulmonary venous PO2 (delta PO2/delta t) was measured during alternately pulsatile and non-pulsatile perfusion in normal lungs and in lungs made edematous by elevation of left atrial pressure. In normal lungs there was no difference in delta PO2/delta t when the two modes of perfusion were compared. In edematous lungs delta PO/delta t was statistically higher during pulsatile perfusion, indicating a beneficial effect of flow- and pressure pulsations, e.g. a better distribution of V/Q ratios throughout the lungs. In a separate series of expts. the advancement of a high O2 front through the airways was measured, and the two perfusion patterns compared. Since no difference was found, we suggest that the phenomenon of "cardiogenic gas mixing" in the airways in vivo is a result of a direct action of the heart on the lungs rather than arterial pulsations.

  1. Reversible cold-induced abnormalities in myocardial perfusion and function in systemic sclerosis

    International Nuclear Information System (INIS)

    Alexander, E.L.; Firestein, G.S.; Weiss, J.L.; Heuser, R.R.; Leitl, G.; Wagner, H.N. Jr.; Brinker, J.A.; Ciuffo, A.A.; Becker, L.C.

    1986-01-01

    The effects of peripheral cold exposure on myocardial perfusion and function were studied in 13 patients with scleroderma without clinically evident myocardial disease. Ten patients had at least one transient, cold-induced, myocardial perfusion defect visualized by thallium-201 scintigraphy, and 12 had reversible, cold-induced, segmental left ventricular hypokinesis by two-dimensional echocardiography. The 10 patients with transient perfusion defects all had anatomically corresponding ventricular wall motion abnormalities. No one in either of two control groups (9 normal volunteers and 7 patients with chest pain and normal coronary arteriograms) had cold-induced abnormalities. This study is the first to show the simultaneous occurrence of cold-induced abnormalities in myocardial perfusion and function in patients with scleroderma. The results suggest that cold exposure in such patients may elicit transient reflex coronary vasoconstriction resulting in reversible myocardial ischemia and dysfunction. Chronic recurrent episodes of coronary spasm may lead to focal myocardial fibrosis

  2. In vivo tomographic study of cerebral blood perfusion with SPECT in hemiparkinsonian monkeys

    International Nuclear Information System (INIS)

    Chen Shengdi; Xu Delong

    1994-01-01

    The authors present data on the utility of functional brain imaging with 99m Tc-ECD and SPECT in the study of MPTP induced hemiparkinsonism in monkeys. Injection of MPTP into the right common carotid artery of 10 rhesus monkeys produced hemiparkinsonism in the contralateral limbs which responded to antiparkinsonian medication. The unilateral neurotoxicity of the MPTP treated side was confirmed biochemically by marked reduction of DA contents in the nigrostriatum and histologically by selective neuronal loss in the substantia nigra. These monkeys with hemiparkinsonism were studied with SPECT using 99m Tc-ECD as perfusion marker. The results of brain scanning showed that the cerebral blood perfusion of MPTP treated side was significantly depleted 20∼90 days after MPTP intoxication, and returned to normal 8 months after perfusion. The experiment indicates that abnormal cerebral blood perfusion is involved in the course of parkinsonian pathophysiology

  3. The benefits of prone SPECT myocardial perfusion imaging in reducing both artifact defects and patient radiation exposure; Beneficio da aquisicao de imagem na posicao Prona em perfusao miocardica com SPECT para reducao de artefatos e exposicao do paciente a radiacao

    Energy Technology Data Exchange (ETDEWEB)

    Stathaki, Maria; Koukouraki, Sophia; Papadaki, Emmanouela; Tsaroucha, Angeliki; Karkavitsas, Nikolaos, E-mail: mariast_cha@yahoo.gr [Department of Nuclear Medicine, University Hospital of Heraklion, Crete (Greece)

    2015-10-15

    Background: Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation. Objectives: To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure. Methods: We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the 'gold standard' for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings. Results: Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects. Conclusion: Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed. (author)

  4. Lung ventilation-perfusion imbalance in pulmonary emphysema: assessment with automated V/Q quotient SPECT.

    Science.gov (United States)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Koike, Hiroaki; Iwanaga, Hideyuki; Tokuda, Osamu; Okada, Munemasa; Matsunaga, Naofumi

    2010-05-01

    Tc-99m-Technegas-MAA single photon emission computed tomography (SPECT)-derived ventilation (V)/perfusion (Q) quotient SPECT was used to assess lung V-Q imbalance in patients with pulmonary emphysema. V/Q quotient SPECT and V/Q profile were automatically built in 38 patients with pulmonary emphysema and 12 controls, and V/Q distribution and V/Q profile parameters were compared. V/Q distribution on V/Q quotient SPECT was correlated with low attenuation areas (LAA) on density-mask computed tomography (CT). Parameters of V/Q profile such as the median, standard deviation (SD), kurtosis and skewness were proposed to objectively evaluate the severity of lung V-Q imbalance. In contrast to uniform V/Q distribution on V/Q quotient SPECT and a sharp peak with symmetrical V/Q distribution on V/Q profile in controls, lung areas showing heterogeneously high or low V/Q and flattened peaks with broadened V/Q distribution were frequently seen in patients with emphysema, including lung areas with only slight LAA. V/Q distribution was also often asymmetric regardless of symmetric LAA. All the proposed parameters of V/Q profile in entire lungs of patients with emphysema showed large variations compared with controls; SD and kurtosis were significantly different from controls (P emphysema. SD and kurtosis of V/Q profile can be adequate parameters to assess the severity of lung V-Q imbalance causing gas-exchange impairment in patients with emphysema.

  5. Prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia: study by 99mTc-sestamibi radionuclide scintigraphy.

    Science.gov (United States)

    Ismail, Ahmed M; Rayan, Mona; Adel, Amr; Demerdash, Salah; Atef, Mohamed; Abdallah, Mohamed; Nammas, Wail

    2014-02-01

    We explored the prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia (CAE), as demonstrated by (99m)Tc-sestamibi scintigraphy. Prospectively, we enrolled 35 patients with angiographically documented CAE and no significant coronary obstruction, who underwent elective coronary angiography. Patients underwent Stress-rest (99m)Tc-sestamibi scintigraphy within 4 days of coronary angiography. They were divided into 2 groups: group I: with normal perfusion scan; and group II: with reversible perfusion defects. The mean age was 49.6 ± 6.9 years; 34 (97.1 %) were males. Seventy-nine (75.2 %) arteries were affected by CAE. Among 79 arteries affected by CAE, affection was diffuse in 37 (46.8 %). Thirteen (37.1 %) patients had normal perfusion scan (group I), whereas 22 (62.9 %) had reversible perfusion defects (group II). Among 22 patients with reversible perfusion defects, 20 (90.9 %) had mild and 2 (9.1 %) had moderate ischemia. Among 49 myocardial segments with reversible perfusion defects, 22 (44.9 %) were basal, 18 (36.7 %) mid-, and 9 (18.4 %) apical segments. Diffuse CAE was significantly more prevalent in group II versus group I, in all 3 major coronary arteries (p < 0.05 for all). In patients with isolated CAE who underwent elective coronary angiography, reversible perfusion defects demonstrated by (99m)Tc-sestamibi scintigraphy were rather prevalent, mostly mild, more likely to affect the basal and mid-segments of the myocardium, and more frequently associated with diffuse ectasia.

  6. Unilateral absence of lung perfusion resulting from endarteritis of the pulmonary artery

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Turini, T.L.

    This case shows endarteritis of left pulmonary artery in the angiographic study with absent perfusion of the left lung in the MAA 131 I scintigraphy. Considerations are made conderning the presumable diagnosis of infection by 'toxocara canis' larval form. The literature review don't point out a similar case. (author) [pt

  7. Utility of Deep Inspiration Breath Hold for Left-Sided Breast Radiation Therapy in Preventing Early Cardiac Perfusion Defects: A Prospective Study

    Energy Technology Data Exchange (ETDEWEB)

    Zagar, Timothy M., E-mail: zagar@med.unc.edu [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Kaidar-Person, Orit [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Tang, Xiaoli [Memorial Sloan Kettering Cancer Center, West Harrison, New York (United States); Jones, Ellen E.; Matney, Jason; Das, Shiva K.; Green, Rebecca L. [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Sheikh, Arif [Department of Radiology, Columbia University, New York, New York (United States); Khandani, Amir H.; McCartney, William H.; Oldan, Jorge Daniel; Wong, Terence Z. [Department of Radiology, University of North Carolina, Chapel Hill, North Carolina (United States); Marks, Lawrence B. [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States)

    2017-04-01

    Purpose: To evaluate early cardiac single photon computed tomography (SPECT) findings after left breast/chest wall postoperative radiation therapy (RT) in the setting of deep inspiration breath hold (DIBH). Methods and Materials: We performed a prospective single-institution single-arm study of patients who were planned for tangential RT with DIBH to the left breast/chest wall (± internal mammary nodes). The DIBH was done by use of a controlled surface monitoring technique (AlignRT, Vision RT Ltd, London, UK). The RT was given with tangential fields and a heart block. Radiation-induced cardiac perfusion and wall motion changes were assessed by pre-RT and 6-month post-RT SPECT scans. A cumulative SPECT summed-rest score was used to quantify perfusion in predefined left ventricle segments. The incidence of wall motion abnormalities was assessed in each of these same segments. Results: A total of 20 patients with normal pre-RT scans were studied; their median age was 56 years (range, 39-72 years). Seven (35%) patients also received irradiation to the left internal mammary chain, and 5 (25%) received an additional RT field to supraclavicular nodes. The median heart dose was 94 cGy (range, 56-200 cGy), and the median V25{sub Gy} was zero (range, 0-0.1). None of the patients had post-RT perfusion or wall motion abnormalities. Conclusions: Our results suggest that DIBH and conformal cardiac blocking for patients receiving tangential RT for left-sided breast cancer is an effective means to avoid early RT-associated cardiac perfusion defects.

  8. Unilateral glaucoma in Sotos syndrome (cerebral gigantism).

    Science.gov (United States)

    Yen, M T; Gedde, S J; Flynn, J T

    2000-12-01

    To report a patient with unilateral glaucoma associated with Sotos syndrome. Sotos syndrome (cerebral gigantism) is a disorder of growth and development with characteristic facial changes and normal endocrine function. Ocular manifestations may also include megalocornea, iris hypoplasia, cataracts, megalophthalmos, strabismus, nystagmus, and retinal dystrophy. Case report. A 50 year-old man with the clinical features of Sotos syndrome presented with complaints of decreased vision in the left eye. Ophthalmologic examination revealed bilateral megalocornea, megalophthalmos, iris hypoplasia and transillumination defects, cataracts, and unilateral glaucoma. Intraocular pressure was lowered, and visual field loss was stabilized with topical medications. Sotos syndrome patients should be examined routinely to allow for early detection and treatment of potential ocular problems, including glaucoma.

  9. Role of adenosine 99MTc sestamibi myocardial perfusion spect in evaluation of symptomatic hypertensives with recent onset left bundle branch block

    International Nuclear Information System (INIS)

    Padma, S.; Sundaram, P.S.; Zachariah, M.; Hariads, K.K.

    2004-01-01

    Objectives: Adenosine pharmacological stress Myocardial Perfusion Imaging (AMPI) is the preferred imaging modality for IHD evaluation in pts with Left Bundle Branch Block (LBBB). Good prognosis has been reported in recent onset LBBB pts with normal MPI. Our aim was to evaluate the utility and analyze the predictive value of SestaMIBI AMPI in symptomatic recent onset LBBB hypertensives for coronary artery disease evaluation. Methods: 29 hypertensive pts, age range 36-72yrs, mean 54+ 6 yrs, M:F- 21:8 with recent onset complete LBBB, under evaluation for typical/atypical angina who had AMPI between Nov 02-Nov 03, were retrospectively analyzed. LBBB was diagnosed ECG wise if there is prolonged QRS complex i.e. 0.125sec or more in sinus/supraventricular rhythm, a QS or rS complex in lead 1, and an R-wave peak time of 0.06sec in leads 1, V5 or V6 with no Q wave in same lead. Pts with prior Myocardial Infarct / revasularisation, pacemaker induced LBBB were excluded. Single day 6 min. Adenosine infusion Stress-rest 99m Tc MIBI gated MPI was performed with a dual head variable angle Gamma Camera at 76-degree angle. Coronary Angiogram (CAG) correlation was available in 24 pts. Results: Myocardial perfusion SPECT images were assessed visually and by a 20-segment model. Location, extent and severity of the LV perfusion defects were evaluated. 6/29 pts (20.7%) had normal stress-rest perfusion in all LV segments.12 (41.4%) had isolated septal fixed defect with normal perfusion in rest of the segments.3 pts (10.3%)showed isolated reversible septal defects while 8(27.6%) had reversible septal defects with reversible defects in other LV segments also. Pts with fixed septal perfusion defect showed moderate to good septal wall thickening in gated SPECT images. While all pts with multiple reversible perfusion defects had angiographically proven coronary artery disease (i.e. 3pts had LAD lesion, 2 had Triple vessel and 3 showed double vessel lesions), 1 out of 3 pts with isolated

  10. Lung perfusion scintigraphy in congenital heart disease

    International Nuclear Information System (INIS)

    Sugimura, Hiroshi; Nagamachi, Shigeki; Hoshi, Hiroaki; Jinnouchi, Seishi; Oonishi, Takashi; Futami, Shigemi; Watanabe, Katsushi

    1990-01-01

    Lung perfusion scintigrams were reviewed retrospectively in 28 patients with congenital heart disease, whose ages ranged from the first year to 16 years with an average age of 5 years and 6 months. Seventy four MBq (2 mCi), 111 MBq (2 mCi), and 185 MBq (5 mCi) of Tc-99m macroaggregated albumin were iv injected in the age groups of 0-3, 4-11, and more than 11 years, respectively. Five minutes later, images were obtained in six projections. Abnormal findings on lung perfusion scintigrams were observed in 13 patients (46%). Of these patients, 8 (29%) had a partially decreased blood flow and 5 (17%) had a decreased blood flow in the unilateral lung. No significant difference in the occurrence of abnormal findings was observed among the age groups, although they tended to occur in younger patients. Sex, underlying conditions, and hemodynamics were also independent of scintigraphically abnormal findings. Even when classifying the patients as having either cyanotic or non-cyanotic heart disease, no significant difference in hemodynamics was observed between the group of abnormal findings and the group of normal findings. Pulmonary arteriography available in all patients failed to reveal abnormal findings, with the exception of pulmonary artery stenosis in 2 patients that corresponded to a decreased blood flow in the unilateral lung. Pulmonary artery stenosis seemed to be responsible for abnormal pulmonary blood flow, although other causes remained uncertain. (N.K.)

  11. Physiologic Evaluation of Ventilation Perfusion Mismatch and Respiratory Mechanics at Different Positive End-expiratory Pressure in Patients Undergoing Protective One-lung Ventilation.

    Science.gov (United States)

    Spadaro, Savino; Grasso, Salvatore; Karbing, Dan Stieper; Fogagnolo, Alberto; Contoli, Marco; Bollini, Giacomo; Ragazzi, Riccardo; Cinnella, Gilda; Verri, Marco; Cavallesco, Narciso Giorgio; Rees, Stephen Edward; Volta, Carlo Alberto

    2018-03-01

    Arterial oxygenation is often impaired during one-lung ventilation, due to both pulmonary shunt and atelectasis. The use of low tidal volume (VT) (5 ml/kg predicted body weight) in the context of a lung-protective approach exacerbates atelectasis. This study sought to determine the combined physiologic effects of positive end-expiratory pressure and low VT during one-lung ventilation. Data from 41 patients studied during general anesthesia for thoracic surgery were collected and analyzed. Shunt fraction, high V/Q and respiratory mechanics were measured at positive end-expiratory pressure 0 cm H2O during bilateral lung ventilation and one-lung ventilation and, subsequently, during one-lung ventilation at 5 or 10 cm H2O of positive end-expiratory pressure. Shunt fraction and high V/Q were measured using variation of inspired oxygen fraction and measurement of respiratory gas concentration and arterial blood gas. The level of positive end-expiratory pressure was applied in random order and maintained for 15 min before measurements. During one-lung ventilation, increasing positive end-expiratory pressure from 0 cm H2O to 5 cm H2O and 10 cm H2O resulted in a shunt fraction decrease of 5% (0 to 11) and 11% (5 to 16), respectively (P ventilation, high positive end-expiratory pressure levels improve pulmonary function without increasing high V/Q and reduce driving pressure.

  12. How to Perfuse: Concepts of Cerebral Protection during Arch Replacement

    Directory of Open Access Journals (Sweden)

    Andreas Habertheuer

    2015-01-01

    Full Text Available Arch surgery remains undoubtedly among the most technically and strategically challenging endeavors in cardiovascular surgery. Surgical interventions of thoracic aneurysms involving the aortic arch require complete circulatory arrest in deep hypothermia (DHCA or elaborate cerebral perfusion strategies with varying degrees of hypothermia to achieve satisfactory protection of the brain from ischemic insults, that is, unilateral/bilateral antegrade cerebral perfusion (ACP and retrograde cerebral perfusion (RCP. Despite sophisticated and increasingly individualized surgical approaches for complex aortic pathologies, there remains a lack of consensus regarding the optimal method of cerebral protection and circulatory management during the time of arch exclusion. Many recent studies argue in favor of ACP with various degrees of hypothermic arrest during arch reconstruction and its advantages have been widely demonstrated. In fact ACP with more moderate degrees of hypothermia represents a paradigm shift in the cardiac surgery community and is widely adopted as an emergent strategy; however, many centers continue to report good results using other perfusion strategies. Amidst this important discussion we review currently available surgical strategies of cerebral protection management and compare the results of recent European multicenter and single-center data.

  13. How to Perfuse: Concepts of Cerebral Protection during Arch Replacement

    Science.gov (United States)

    Habertheuer, Andreas; Wiedemann, Dominik; Kocher, Alfred; Laufer, Guenther; Vallabhajosyula, Prashanth

    2015-01-01

    Arch surgery remains undoubtedly among the most technically and strategically challenging endeavors in cardiovascular surgery. Surgical interventions of thoracic aneurysms involving the aortic arch require complete circulatory arrest in deep hypothermia (DHCA) or elaborate cerebral perfusion strategies with varying degrees of hypothermia to achieve satisfactory protection of the brain from ischemic insults, that is, unilateral/bilateral antegrade cerebral perfusion (ACP) and retrograde cerebral perfusion (RCP). Despite sophisticated and increasingly individualized surgical approaches for complex aortic pathologies, there remains a lack of consensus regarding the optimal method of cerebral protection and circulatory management during the time of arch exclusion. Many recent studies argue in favor of ACP with various degrees of hypothermic arrest during arch reconstruction and its advantages have been widely demonstrated. In fact ACP with more moderate degrees of hypothermia represents a paradigm shift in the cardiac surgery community and is widely adopted as an emergent strategy; however, many centers continue to report good results using other perfusion strategies. Amidst this important discussion we review currently available surgical strategies of cerebral protection management and compare the results of recent European multicenter and single-center data. PMID:26713319

  14. An investigation of the trade-off between the count level and image quality in myocardial perfusion SPECT using simulated images: the effects of statistical noise and object variability on defect detectability

    International Nuclear Information System (INIS)

    He Xin; Links, Jonathan M; Frey, Eric C

    2010-01-01

    Quantum noise as well as anatomic and uptake variability in patient populations limits observer performance on a defect detection task in myocardial perfusion SPECT (MPS). The goal of this study was to investigate the relative importance of these two effects by varying acquisition time, which determines the count level, and assessing the change in performance on a myocardial perfusion (MP) defect detection task using both mathematical and human observers. We generated ten sets of projections of a simulated patient population with count levels ranging from 1/128 to around 15 times a typical clinical count level to simulate different levels of quantum noise. For the simulated population we modeled variations in patient, heart and defect size, heart orientation and shape, defect location, organ uptake ratio, etc. The projection data were reconstructed using the OS-EM algorithm with no compensation or with attenuation, detector response and scatter compensation (ADS). The images were then post-filtered and reoriented to generate short-axis slices. A channelized Hotelling observer (CHO) was applied to the short-axis images, and the area under the receiver operating characteristics (ROC) curve (AUC) was computed. For each noise level and reconstruction method, we optimized the number of iterations and cutoff frequencies of the Butterworth filter to maximize the AUC. Using the images obtained with the optimal iteration and cutoff frequency and ADS compensation, we performed human observer studies for four count levels to validate the CHO results. Both CHO and human observer studies demonstrated that observer performance was dependent on the relative magnitude of the quantum noise and the patient variation. When the count level was high, the patient variation dominated, and the AUC increased very slowly with changes in the count level for the same level of anatomic variability. When the count level was low, however, quantum noise dominated, and changes in the count level

  15. Improved visualization of delayed perfusion in lung MRI

    International Nuclear Information System (INIS)

    Risse, Frank; Eichinger, Monika; Kauczor, Hans-Ulrich; Semmler, Wolfhard; Puderbach, Michael

    2011-01-01

    Introduction: The investigation of pulmonary perfusion by three-dimensional (3D) dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was proposed recently. Subtraction images are generated for clinical evaluation, but temporal information is lost and perfusion defects might therefore be masked in this process. The aim of this study is to demonstrate a simple analysis strategy and classification for 3D-DCE-MRI perfusion datasets in the lung without omitting the temporal information. Materials and methods: Pulmonary perfusion measurements were performed in patients with different lung diseases using a 1.5 T MR-scanner with a time-resolved 3D-GRE pulse sequence. 25 3D-volumes were acquired after iv-injection of 0.1 mmol/kg KG Gadolinium-DTPA. Three parameters were determined for each pixel: (1) peak enhancement S n,max normalized to the arterial input function to detect regions of reduced perfusion; (2) time between arterial peak enhancement in the large pulmonary artery and tissue peak enhancement τ to visualize regions with delayed bolus onset; and (3) ratio R = S n,max /τ was calculated to visualize impaired perfusion, irrespectively of whether related to reduced or delayed perfusion. Results: A manual selection of peak perfusion images is not required. Five different types of perfusion can be found: (1) normal perfusion; (2) delayed non-reduced perfusion; (3) reduced non-delayed perfusion; (4) reduced and delayed perfusion; and (5) no perfusion. Types II and IV could not be seen in subtraction images since the temporal information is necessary for this purpose. Conclusions: The analysis strategy in this study allows for a simple and observer-independent visualization and classification of impaired perfusion in dynamic contrast-enhanced pulmonary perfusion MRI by using the temporal information of the datasets.

  16. A Case of Swyer-James (Macleod’s Syndrome with Bilateral Involvement

    Directory of Open Access Journals (Sweden)

    Ömer Özbudak

    2005-01-01

    Full Text Available Swyer-James (Macleod’s syndrome (SJMS is a rare disorder thought to be a complication of childhood infections. Unilateral hyperlucency, reduced lung volume, diminished vascular markings and bronchiectasis may be detected on radiological analysis. Bilateral involvement is rare. We present a 20-yearl-old man who was diagnosed as having bilateral SJMS by radiological analysis and ventilation-perfusion scintigraphy.

  17. Improvement of myocardial perfusion status in response to indian vedic breathing

    International Nuclear Information System (INIS)

    Anand, Y.N.I.; Muthu, G.S.

    2004-01-01

    Introduction: Yoga is the buzz word all over the world today. Amidst their busy schedule, people tend to ignore their personal health. Management of various disorders, especially those involving interventions, surgical or radiological, is very expensive. The Indian Vedic Exercises, of which Pranaayaama is one, emphasize on prevention of the diseases in order to keep the individual in good health. It is equally applicable to those who have already suffered from various disorders and in whom both improvement and/or avoidance of further deterioration are required. However, no Objective assessment of the disease status in response to these exercises has been reported so far. Objectives: This pilot study has been undertaken on patients with reversible myocardial perfusion defects to Objectively monitor the improvements in the myocardial perfusion in response to a breathing exercise, Pranayama, a breathing technique prescribed in the Indian Vedic Sciences. Methods: Two patients who were found to have reversible myocardial perfusion defects were taken up in this study. These defects were diagnosed from the myocardial perfusion SPECT done in stressed (on Tread Mill) and resting states with 99m Technetium labeled MIBI.These patients were taught the pranayama technique which is done for about 30 minutes every day. At the end of four months from the commencement of this technique, the myocardial perfusion SPECT studies were repeated. Details of the exercise in the form of a CD are available on request. Results: Overall good improvements were observed in all the quantitative parameters in the TMT and SPECT studies in the studies done after the pranayama procedures in both the patients. Perfusion defects seen in the stress images of the initial studies have almost completely reversed in the stress images of the later study. Patients are asymptomatic and are leading a comfortable life. Conclusion: This is only a study of two cases to Objectively evaluate the effects of pranayama

  18. Nuclear cardiology: Myocardial perfusion and function

    International Nuclear Information System (INIS)

    Seldin, D.W.

    1991-01-01

    Myocardial perfusion studies continue to be a major focus of research, with new investigations of the relationship of exercise-redistribution thallium imaging to diagnosis, prognosis, and case management. The redistribution phenomenon, which seemed to be fairly well understood a few years ago, is now recognized to be much more complex than originally thought, and various strategies have been proposed to clarify the meaning of persistent defects. Pharmacologic intervention with dipyridamole and adenosine has become available as an alternative to exercise, and comparisons with exercise imaging and catheterization results have been described. Thallium itself is no longer the sole single-photon perfusion radiopharmaceutical; two new technetium agents are now widely available. In addition to perfusion studies, advances in the study of ventricular function have been made, including reports of studies performed in conjunction with technetium perfusion studies, new insights into cardiac physiology, and the prognostic and case-management information that function studies provide. Finally, work has continued with monoclonal antibodies for the identification of areas of myocyte necrosis. 41 references

  19. A new clinical tool for the quantification of myocardial CT perfusion imaging in patients with suspected Ischemic Heart Disease

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Muñoz, A.; Dux-Santoy Hurtado, L.; Rodriguez Palomares, J.L.; Piella Fenoy, G.

    2016-07-01

    In the clinical practice, the evaluation of myocardial perfusion by using Computed Tomography (CT) Imaging is usually performed visually or semi-quantitatively. The scarcity of quantitative perfusion data not always allows a proper diagnose of patients which are suspected of suffering from some diseases, such as Ischemic Heart Disease (IHD). In this work, a clinical tool for the automatic quantification of myocardial perfusion in patients with suspected IHD is proposed. Myocardial perfusion is assessed based on a combined diagnosis protocol (CT/CTP protocol) which involves the acquisition of two contrastenhanced CT images, one obtained at rest and another acquired under pharmacological stress. The clinical tool allows the automatic quantification of perfusion in different myocardial segments defined according to the 16-AHA-segmentation model of the left ventricle, by providing the mean of Hounsfield Units in those regions. Based on this analysis, the clinicians can compare the values at baseline and at hyperemia, and they can better determine hypoperfusion defects in patients with IHD. The validation of the clinical tool was performed by comparing automatic and manual perfusion measurements of 10 patients with suspected IHD who were previously assessed with Single Photon Emission Computed Tomography (SPECT) for perfusion analysis. A strong linear correlation was found between the automatic and manual results. Afterwards, perfusion defects obtained from CT/CTP protocol were compared to perfusion defects from SPECT, to assess the applicability of this clinical tool for the diagnosis of IHD. (Author)

  20. Diagnostic performance of dual-energy CT stress myocardial perfusion imaging: direct comparison with cardiovascular MRI.

    Science.gov (United States)

    Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K

    2014-12-01

    The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.

  1. Utilization of the organ care system as ex-vivo lung perfusion after cold storage transportation.

    Science.gov (United States)

    Mohite, P N; Maunz, O; Popov, A-F; Zych, B; Patil, N P; Simon, A R

    2015-11-01

    The Organ Care System (OCS) allows perfusion and ventilation of the donor lungs under physiological conditions. Ongoing trials to compare preservation with OCS Lung with standard cold storage do not include donor lungs with suboptimal gas exchange and donor lungs treated with OCS following cold storage transportation. We present a case of a 48-yr-old man who received such lungs after cold storage transportation treated with ex-vivo lung perfusion utilizing OCS. © The Author(s) 2015.

  2. Detection of myocardial ischemia of hypertrophic cardiomyopathy with gated 99Tcm-MIBI myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Jia Peng; Guo Wanhua; Du Minghua; Gao Ling

    2010-01-01

    Objective: To evaluate the value of gated 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in detection of myocardial ischemia in hypertrophic cardiomyopathy. Methods: Sixty-nine patients with clinically proven hypertrophic cardiomyopathy were divided into 2 groups using coronary angiogram as 'gold standard': positive group (n=19, narrowing ≥ 50%) and negative group (n=50, narrowing 99 Tc m -MIBI myocardial perfusion imaging was performed and positive in all 69 patients (41 males, 28 females, aged 35-75 years). Comparative analysis between the two groups was carried out using t-test. Results: In the positive group, reversible and irreversible perfusion defects were detected in 9 and 10 patients, respectively. Left ventricular ejection fraction (LVEF) increased to (69.1 ± 2.8)% in 8 patients and decreased to (42.8 ± 2.1)% in 11 patients. In the negative group, reversible and irreversible perfusion defects were found in 37 and 13 patients, respectively. LVEF increased to (70.8 ± 4.0)% in 38 patients and decreased to (48.9 ± 2.7)% in 12 patients. The values of ischemic area, severity and extent of perfusion defect, and LVEF were significantly different between the two groups (t=9.28, 16.51, 2.65; P 99 Tc m -MIBI myocardial perfusion imaging is valuable in assessing patients with hypertrophic cardiomyopathy. Detection for the presence or absence of coexisting coronary artery disease and myocardial ischemia has an important prognostic indication and management indication for these patients. (authors)

  3. Characteristic findings of exercise ECG test, perfusion SPECT and coronary angiography in patients with exercise induced myocardial stunning

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Seo, Ji Hyoung; Bae, Jin Ho; Jeong, Shin Young; Park, Hun Sik; Lee, Jae Tae; Chae, Shung Chull; Lee, Kyu Bo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    2004-06-01

    Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV ejection fraction (LVEF) was {>=}5% lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1% (non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs 9.2%, p=0.029; severity 13.5 vs 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis(80{approx}99%) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than

  4. Effects of assisted and variable mechanical ventilation on cardiorespiratory interactions in anesthetized pigs

    International Nuclear Information System (INIS)

    Beda, Alessandro; Güldner, Andreas; Carvalho, Nadja C; Franke, Susanne; Uhlig, Christopher; Koch, Thea; De Abreu, Marcelo Gama; Simpson, David M; Pelosi, Paolo

    2012-01-01

    The physiological importance of respiratory sinus arrhythmia (RSA) and cardioventilatory coupling (CVC) has not yet been fully elucidated, but these phenomena might contribute to improve ventilation/perfusion matching, with beneficial effects on gas exchange. Furthermore, decreased RSA amplitude has been suggested as an indicator of impaired autonomic control and poor clinical outcome, also during positive-pressure mechanical ventilation (MV). However, it is currently unknown how different modes of MV, including variable tidal volumes (V T ), affect RSA and CVC during anesthesia. We compared the effects of pressure controlled (PCV) versus pressure assisted (PSV) ventilation, and of random variable versus constant V T , on RSA and CVC in eight anesthetized pigs. At comparable depth of anesthesia, global hemodynamics, and ventilation, RSA amplitude increased from 20 ms in PCV to 50 ms in PSV (p < 0.05). CVC was detected (using proportional Shannon entropy of the interval between each inspiration onset and the previous R-peak in ECG) in two animals in PCV and seven animals in PSV. Variable V T did not significantly influence these phenomena. Furthermore, heart period and systolic arterial pressure oscillations were in phase during PCV but in counter-phase during PSV. At the same depth of anesthesia in pigs, PSV increases RSA amplitude and CVC compared to PCV. Our data suggest that the central respiratory drive, but not the baroreflex or the mechano-electric feedback in the heart, is the main mechanism behind the RSA increase. Hence, differences in RSA and CVC between mechanically ventilated patients might reflect the difference in ventilation mode rather than autonomic impairment. Also, since gas exchange did not increase from PCV to PSV, it is questionable whether RSA has any significance in improving ventilation/perfusion matching during MV. (paper)

  5. Effects of assisted and variable mechanical ventilation on cardiorespiratory interactions in anesthetized pigs.

    Science.gov (United States)

    Beda, Alessandro; Güldner, Andreas; Simpson, David M; Carvalho, Nadja C; Franke, Susanne; Uhlig, Christopher; Koch, Thea; Pelosi, Paolo; de Abreu, Marcelo Gama

    2012-03-01

    The physiological importance of respiratory sinus arrhythmia (RSA) and cardioventilatory coupling (CVC) has not yet been fully elucidated, but these phenomena might contribute to improve ventilation/perfusion matching, with beneficial effects on gas exchange. Furthermore, decreased RSA amplitude has been suggested as an indicator of impaired autonomic control and poor clinical outcome, also during positive-pressure mechanical ventilation (MV). However, it is currently unknown how different modes of MV, including variable tidal volumes (V(T)), affect RSA and CVC during anesthesia. We compared the effects of pressure controlled (PCV) versus pressure assisted (PSV) ventilation, and of random variable versus constant V(T), on RSA and CVC in eight anesthetized pigs. At comparable depth of anesthesia, global hemodynamics, and ventilation, RSA amplitude increased from 20 ms in PCV to 50 ms in PSV (p < 0.05). CVC was detected (using proportional Shannon entropy of the interval between each inspiration onset and the previous R-peak in ECG) in two animals in PCV and seven animals in PSV. Variable V(T) did not significantly influence these phenomena. Furthermore, heart period and systolic arterial pressure oscillations were in phase during PCV but in counter-phase during PSV. At the same depth of anesthesia in pigs, PSV increases RSA amplitude and CVC compared to PCV. Our data suggest that the central respiratory drive, but not the baroreflex or the mechano-electric feedback in the heart, is the main mechanism behind the RSA increase. Hence, differences in RSA and CVC between mechanically ventilated patients might reflect the difference in ventilation mode rather than autonomic impairment. Also, since gas exchange did not increase from PCV to PSV, it is questionable whether RSA has any significance in improving ventilation/perfusion matching during MV.

  6. An attempt of thallium-201 myocardial perfusion imaging during transient coronary arterial occlusion by PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Katahira, Toshio

    1989-01-01

    To evaluate the myocardial perfusion during transient coronary occlusion, we attempted to obtain the myocardial scintigraphy during percutaneous transluminal coronary angioplasty (PTCA). Tl-201 was injected at the last inflation of angioplastic balloon and occlusion was kept on for 60 sec. Planar images or SPECT were obtained immediately after PTCA. With this protocol, myocardial perfusion defects were observed during PTCA and fully redistributed 3 hours after Tl injection. Extent of ischemic lesions were almost same as that observed during exercise in two cases without collateral vessels. In a case with well visualized collateral vessels, perfusion defect was smaller in PTCA images than that in exercise stressed images. We conclude that intravenous injection of Tl-201 during PTCA is useful to assess the alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedure. (author)

  7. Dynamic (4D) CT perfusion offers simultaneous functional and anatomical insights into pulmonary embolism resolution

    Energy Technology Data Exchange (ETDEWEB)

    Mirsadraee, Saeed, E-mail: saeed.mirsadraee@ed.ac.uk [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Reid, John H.; Connell, Martin [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); MacNee, William; Hirani, Nikhil [The Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Murchison, John T. [Department of Radiology, Royal Infirmary of Edinburgh, 51 Little France Crescent, Edinburgh EH16 4SA (United Kingdom); Beek, Edwin J. van [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom)

    2016-10-15

    Objective: Resolution and long-term functional effects of pulmonary emboli are unpredictable. This study was carried out to assess persisting vascular bed perfusion abnormalities and resolution of arterial thrombus in patients with recent pulmonary embolism (PE). Methods and materials: 26 Patients were prospectively evaluated by dynamic (4D) contrast enhanced CT perfusion dynamic pulmonary CT perfusion. Intermittent volume imaging was performed every 1.5–1.7 s during breath-hold and perfusion values were calculated by maximum-slope technique. Thrombus load (modified Miller score; MMS) and ventricular diameter were determined. Perfusion maps were visually scored and correlated with residual endoluminal filling defects. Results: The mean initial thrombus load was 13.1 ± 4.6 MMS (3–16), and 1.2 ± 2.1 MMS (0–8) at follow up. From the 24 CTPs with diagnostic quality perfusion studies, normal perfusion was observed in 7 (29%), and mildly-severely abnormal in 17 (71%). In 15 patients with no residual thrombus on follow up CTPA, normal perfusion was observed in 6, and abnormal perfusion in 9. Perfusion was abnormal in all patients with residual thrombus on follow up CTPA. Pulmonary perfusion changes were classified as reduced (n = 4), delayed (systemic circulation pattern; n = 5), and absent (no-flow; n = 5). The right ventricle was dilated in 12/25 (48%) at presentation, and normal in all 26 follow up scans. Weak correlation was found between initial ventricular dilatation and perfusion abnormality at follow up (r = 0.15). Conclusions: Most patients had substantial perfusion abnormality at 3–6 months post PE. Abnormal perfusion patterns were frequently observed in patients and in regions with no corresponding evidence of residual thrombus on CTPA. Some defects exhibit delayed, presumed systemic, enhancement (which we have termed ‘stunned’ lung). CT perfusion provides combined anatomical and functional information about PE resolution.

  8. Relations among impaired coronary flow reserve, left ventricular hypertrophy and thallium perfusion defects in hypertensive patients without obstructive coronary artery disease

    International Nuclear Information System (INIS)

    Houghton, J.L.; Frank, M.J.; Carr, A.A.; von Dohlen, T.W.; Prisant, L.M.

    1990-01-01

    Invasive Doppler catheter-derived coronary flow reserve, echocardiographic measurements of left ventricular hypertrophy and intravenous dipyridamole-limited stress thallium-201 scintigraphy were compared in 48 patients (40 were hypertensive or diabetic) with clinical ischemic heart disease and no or minor coronary artery disease. Abnormal vasodilator reserve (ratio less than 3:1) occurred in 50% of the study group and markedly abnormal reserve (less than or equal to 2:1) occurred in 27%. Coronary vasodilator reserve was significantly lower (2.2 +/- 0.8 versus 3.5 +/- 1.3, p = 0.003) and indexed left ventricular mass significantly higher (152.6 +/- 42.2 versus 113.6 +/- 24.0 g, p = 0.0007) in patients with a positive (n = 11) versus a negative (n = 32) thallium perfusion scan. Coronary flow reserve was linearly related in coronary basal flow velocity as follows: y = -0.17x + 4.59; r = -0.57; p = 0.00002. The decrement in flow reserve was not linearly related to the degree of left ventricular hypertrophy. Abnormal vasodilator reserve subsets found in hypertensive patients were defined on the basis of basal flow velocity, indexed left ventricular mass and clinical factors. In this series, diabetes did not cause a detectable additional decrement in flow reserve above that found with hypertension alone. These findings demonstrate that thallium perfusion defects are associated with depressed coronary vasodilator reserve in hypertensive patients without obstructive coronary artery disease. Left ventricular hypertrophy by indexed mass criteria is predictive of which hypertensive patients are likely to have thallium defects

  9. Value of T1-201 myocardial perfusion scan for predicting prognosis in patients with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yutaka; Tomoda, Haruo [Tokai Univ., Isehara, Kanagawa (Japan). School of Medicine; Sugihara, Masami

    1983-05-01

    The extent of Tl-201 perfusion defects was determined in three views by the average ratio of perfusion defects to that of the left ventricle. As the percent Tl-201 defect index increased, the peak value of creatine phosphokinase, the grade of Peel index, incidence of congestion on the initial chest X-ray, and pulmonary artery end-diastolic pressure all gradually increased. In 48 patients followed for 23 months on the average after discharge, the incidence of congestive heart failure and ventricular premature beat also increased. The prognosis was particulary poor in patients who had the percent Tl-201 defect index greater than 40%.

  10. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    International Nuclear Information System (INIS)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves; Delluc, Aurelien; Couturaud, Francis; Le Gal, Gregoire

    2014-01-01

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  11. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Service de medecine nucleaire, Brest (France); Delluc, Aurelien; Couturaud, Francis [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Le Gal, Gregoire [Universite Europeenne de Bretagne, Brest (France); University of Ottawa, Ottawa Hospital Research Institute, Ottawa (Canada); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Universite de Brest, Brest (France)

    2014-10-15

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  12. Myocardial perfusion imaging with thalium 201 during and after exercise in patients with coronary heart

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, P B; Villacorta, E V; Monzon, O P; Torres, Jr, J F; Guzman, S V

    1977-07-01

    A unique, non-invasive technique for the evaluation of the regional myocardial perfusion of patients with coronary heart disease has been developed. This entails the use of radionuclide, like thallium (Tl-201), which concentrates in the normal myocardium, leaving areas of ischemia or scarring or ''cold'' perfusion defects. Myocardial perfusion imaging in conjunction with graded exercise testing significantly increases the positivity of the stress test alone among patients with classic angina from 80% to 95%. It gives invaluable information as to the site and extent of the lesion and its reversibility. Among the patients with ECG Q waves indicative of previous infarction, image defects were detected in 93.7%; reversible ischemia co-existing with the infarction was also demonstrated.

  13. Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis - initial results

    International Nuclear Information System (INIS)

    Eichinger, Monika; Puderbach, Michael; Zuna, Ivan; Kauczor, Hans-Ulrich; Fink, Christian; Gahr, Julie; Mueller, Frank-Michael; Ley, Sebastian; Plathow, Christian; Tuengerthal, Siegfried

    2006-01-01

    This paper is a feasibility study of magnetic resonance imaging (MRI) of lung perfusion in children with cystic fibrosis (CF) using contrast-enhanced 3D MRI. Correlation assessment of perfusion changes with structural abnormalities. Eleven CF patients (9 f, 2 m; median age 16 years) were examined at 1.5 T. Morphology: HASTE coronal, transversal (TR/TE/α/ST: 600 ms/28 ms/180 /6 mm), breath-hold 18 s. Perfusion: Time-resolved 3D GRE pulse sequence (FLASH, TE/TR/α: 0.8/1.9 ms/40 ), parallel imaging (GRAPPA, PAT 2). Twenty-five data sets were acquired after intravenous injection of 0.1 mmol/kg body weight of gadodiamide, 3-5 ml/s. A total of 198 lung segments were analyzed by two radiologists in consensus and scored for morphological and perfusion changes. Statistical analysis was performed by Mantel-Haenszel chi-square test. Results showed that perfusion defects were observed in all patients and present in 80% of upper, and 39% of lower lobes. Normal lung parenchyma showed homogeneous perfusion (86%, P<0.0001). Severe morphological changes led to perfusion defects (97%, P<0.0001). Segments with moderate morphological changes showed normal (53%) or impaired perfusion (47%). In conclusion, pulmonary perfusion is easy to judge in segments with normal parenchyma or severe changes. In moderately damaged segments, MRI of lung perfusion may help to better assess actual functional impairment. Contrast-enhanced 3D MRI of lung perfusion has the potential for early vascular functional assessment and therapy control in CF patients. (orig.)

  14. Influence of angiographic collateral circulation on myocardial perfusion in patients with chronic total occlusion of a single coronary artery and no prior myocardial infarction.

    Science.gov (United States)

    Aboul-Enein, Fatma; Kar, Saibal; Hayes, Sean W; Sciammarella, Maria; Abidov, Aiden; Makkar, Raj; Friedman, John D; Eigler, Neal; Berman, Daniel S

    2004-06-01

    The functional role of various angiographic grades for coronary collaterals remains controversial. The aim of this study was to assess the influence of the Rentrop angiographic grading of coronary collaterals on myocardial perfusion in patients with single-vessel chronic total occlusion (CTO) and no prior myocardial infarction (MI). The study included 56 patients with single-vessel CTO and no prior MI who underwent rest-stress myocardial perfusion SPECT and coronary angiography within 6 mo. All patients had angiographic evidence of coronary collaterals. Patients were divided according to the Rentrop classification: Group I had grade 1 or 2 (n = 25) and group II had grade 3 collaterals (n = 31). Group I had a higher frequency of resting regional wall motion abnormalities on left ventriculography (52.6% vs. 19.2% [P = 0.019]). The mean perfusion scores of the overall population showed severe and extensive stress perfusion defects (summed stress score of 14.1 +/- 7.1 and summed difference score of 12.9 +/- 6.9) but minimal resting perfusion defects (summed rest score of 1.0 +/- 2.7). No perfusion scores differed between the 2 groups. The perfusion findings suggested that chronic stunning rather than hibernation is the principal cause of regional wall motion abnormalities in these patients. In the setting of single-vessel CTO and no prior MI, coronary collaterals appear to protect against resting perfusion defects. Excellent angiographic collaterals may prevent resting regional wall motion abnormalities but do not appear to protect against stress-induced perfusion defects.

  15. Theoretical study of inspiratory flow waveforms during mechanical ventilation on pulmonary blood flow and gas exchange.

    Science.gov (United States)

    Niranjan, S C; Bidani, A; Ghorbel, F; Zwischenberger, J B; Clark, J W

    1999-08-01

    A lumped two-compartment mathematical model of respiratory mechanics incorporating gas exchange and pulmonary circulation is utilized to analyze the effects of square, descending and ascending inspiratory flow waveforms during mechanical ventilation. The effects on alveolar volume variation, alveolar pressure, airway pressure, gas exchange rate, and expired gas species concentration are evaluated. Advantages in ventilation employing a certain inspiratory flow profile are offset by corresponding reduction in perfusion rates, leading to marginal effects on net gas exchange rates. The descending profile provides better CO2 exchange, whereas the ascending profile is more advantageous for O2 exchange. Regional disparities in airway/lung properties create maldistribution of ventilation and a concomitant inequality in regional alveolar gas composition and gas exchange rates. When minute ventilation is maintained constant, for identical time constant disparities, inequalities in compliance yield pronounced effects on net gas exchange rates at low frequencies, whereas the adverse effects of inequalities in resistance are more pronounced at higher frequencies. Reduction in expiratory air flow (via increased airway resistance) reduces the magnitude of upstroke slope of capnogram and oxigram time courses without significantly affecting end-tidal expired gas compositions, whereas alterations in mechanical factors that result in increased gas exchanges rates yield increases in CO2 and decreases in O2 end-tidal composition values. The model provides a template for assessing the dynamics of cardiopulmonary interactions during mechanical ventilation by combining concurrent descriptions of ventilation, capillary perfusion, and gas exchange. Copyright 1999 Academic Press.

  16. Low pulmonary artery flush perfusion pressure combined with high positive end-expiratory pressure reduces oedema formation in isolated porcine lungs

    International Nuclear Information System (INIS)

    Schumann, Stefan; Schließmann, Stephan J; Wagner, Giskard; Goebel, Ulrich; Priebe, Hans-Joachim; Guttmann, Josef; Kirschbaum, Andreas

    2010-01-01

    Flush perfusion of the pulmonary artery with organ protection solution is a standard procedure before lung explantation. However, rapid flush perfusion may cause pulmonary oedema which is deleterious in the lung transplantation setting. In this study we tested the hypotheses that high pulmonary perfusion pressure contributes to the development of pulmonary oedema and positive end-expiratory pressure (PEEP) counteracts oedema formation. We expected oedema formation to increase weight and decrease compliance of the lungs on the basis of a decrease in alveolar volume as fluid replaces alveolar air spaces. The pulmonary artery of 28 isolated porcine lungs was perfused with a low-potassium dextrane solution at low (mean 27 mmHg) or high (mean 40 mmHg) pulmonary artery pressure (PAP) during mechanical ventilation at low (4 cmH 2 O) or high (8 cmH 2 O) PEEP, respectively. Following perfusion and storage, relative increases in lung weight were smaller (p < 0.05) during perfusion at low PAP (62 ± 32% and 42 ± 26%, respectively) compared to perfusion at high PAP (133 ± 54% and 87 ± 30%, respectively). Compared to all other PAP–PEEP combinations, increases in lung weight were smallest (44 ± 9% and 27 ± 12%, respectively), nonlinear intratidal lung compliance was largest (46% and 17% respectively, both p < 0.05) and lung histology showed least infiltration of mononuclear cells in the alveolar septa, and least alveolar destruction during the combination of low perfusion pressure and high PEEP. The findings suggest that oedema formation during pulmonary artery flush perfusion in isolated and ventilated lungs can be reduced by choosing low perfusion pressure and high PEEP. PAP–PEEP titration to minimize pulmonary oedema should be based on lung mechanics and PAP monitoring

  17. Myocardial perfusion abnormalities in asymptomatic patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Hosenpud, J.D.; Montanaro, A.; Hart, M.V.; Haines, J.E.; Specht, H.D.; Bennett, R.M.; Kloster, F.E.

    1984-01-01

    Accelerated coronary artery disease and myocardial infarction in young patients with systemic lupus erythematosus is well documented; however, the prevalence of coronary involvement is unknown. Accordingly, 26 patients with systemic lupus were selected irrespective of previous cardiac history to undergo exercise thallium-201 cardiac scintigraphy. Segmental perfusion abnormalities were present in 10 of the 26 studies (38.5 percent). Five patients had reversible defects suggesting ischemia, four patients had persistent defects consistent with scar, and one patient had both reversible and persistent defects in two areas. There was no correlation between positive thallium results and duration of disease, amount of corticosteroid treatment, major organ system involvement or age. Only a history of pericarditis appeared to be associated with positive thallium-201 results (p less than 0.05). It is concluded that segmental myocardial perfusion abnormalities are common in patients with systemic lupus erythematosus. Whether this reflects large-vessel coronary disease or small-vessel abnormalities remains to be determined

  18. Regional Ventilation Changes in Severe Asthma after Bronchial Thermoplasty with 3He MR Imaging and CT

    Science.gov (United States)

    Thomen, Robert P.; Sheshadri, Ajay; Quirk, James D.; Kozlowski, Jim; Ellison, Henry D.; Szczesniak, Rhonda D.; Castro, Mario

    2015-01-01

    Purpose To quantify regional lung ventilation in healthy volunteers and patients with severe asthma (both before and after thermoplasty) by using a combination of helium 3 (3He) magnetic resonance (MR) imaging and computed tomography (CT), with the intention of developing more effective image-guided treatments for obstructive lung diseases. Materials and Methods With approval of the local institutional review board, informed consent, and an Investigational New Drug Exemption, six healthy volunteers and 10 patients with severe asthma were imaged in compliance with HIPAA regulations by using both multidetector CT and 3He MR imaging. Individual bronchopulmonary segments were labeled voxel by voxel from the CT images and then registered to the 3He MR images by using custom software. The 3He signal intensity was then analyzed by evaluating the volume-weighted fraction of total-lung signal intensity present in each segment (segmental ventilation percentage [SVPsegmental ventilation percentage]) and by identifying the whole-lung defect percentage and the segmental defect percentage. Of the 10 patients with asthma, seven received treatment with bronchial thermoplasty and were imaged with 3He MR a second time. Changes in segmental defect percentages and whole-lung defect percentages are presented. Results Ventilation measures for healthy volunteers yielded smaller segment-to-segment variation (mean SVPsegmental ventilation percentage, 100% ± 18 [standard deviation]) than did the measures for patients with severe asthma (mean SVPsegmental ventilation percentage, 97% ± 23). Patients with asthma also demonstrated larger segmental defect percentages (median, 13.5%; interquartile range, 8.9%–17.8%) than healthy volunteers (median, 6%; interquartile range, 5.6%–6.3%). These quantitative results confirm what is visually observed on the 3He images. A Spearman correlation of r = −0.82 was found between the change in whole-lung defect percentage and the number of days between

  19. Pretest clinical diagnosis of coronary artery disease and stress myocardial perfusion scintigram

    International Nuclear Information System (INIS)

    Kasalicky, J.; Kovac, I.; Lanska, V.

    2001-01-01

    To assess the probability of perfusion defects at exercise stress myocardial perfusion SPECT scintigraphy from pretest clinical diagnosis (medical personal history, previous ergometric investigation). To determine the value of clinical factors for probability of scintigraphic defects with respect to avoiding unnecessary investigation in subjects with low probability of abnormal scintigrams. 2143 subjects (1235 men, 908 women) were investigated by SPECT perfusion scintigraphy at stepwise increasing exercise stress. They were divided into three groups with regard to their medical history and exercise test at scintigraphy: subjects without any signs of coronary artery disease (CAD), patients with high likelihood of CAD (i.e., typical anginal pain, in particular at stress, positive stress ECG changes, angiographically documented important CAD) and patients after myocardial infarction (MI). Important risk factors (hypertension, diabetes, age and sex), as well as the role of revascularisation procedures, were taken into account for multiple logistic regression in order to express their importance for the odds of scintigraphic defect visualisation. Perfusion scintigraphic defects (PSD) were found in 5.2% of subjects without signs of CAD, in contrast to patients with manifest CAD (68.8% with PSD) and in those after MI (90.2% with PSD). There were other important factors corroborating the likelihood of PSD (in decreasing order of importance): diabetes, male, ECG changes at stress, increasing age. Successful revascularisation improved scintigraphic images. The examination of CAD symptom-free subjects, in particular with atypical chest discomfort, is useless. SMPS in patients after documented MI is to be carried out for other intended purposes, not for CAD diagnosis only. SMPS is highly recommended in patients with CAD symptoms and high CAD probability in order to decide further treatment and prognosis. (author)

  20. The Transcranial Doppler Sonography for Optimal Monitoring and Optimization of Cerebral Perfusion in Aortic Arch Surgery: A Case Series.

    Science.gov (United States)

    Ghazy, Tamer; Darwisch, Ayham; Schmidt, Torsten; Nguyen, Phong; Elmihy, Sohaila; Fajfrova, Zuzana; Zickmüller, Claudia; Matschke, Klaus; Kappert, Utz

    2017-06-16

    To analyze the feasibility and advantages of transcranial doppler sonography (TCD) for monitoring and optimization of selective cerebral perfusion (SCP) in aortic arch surgery. From April 2013 to April 2014, nine patients with extensive aortic pathology underwent surgery under moderate hypothermic cardiac arrest with unilateral antegrade SCP under TCD monitoring in our institution. Adequate sonographic window and visualization of circle of Willis were to be confirmed. Intraoperatively, a cerebral cross-filling of the contralateral cerebral arteries on the unilateral SCP was to be confirmed with TCD. If no cross-filling was confirmed, an optimization of the SCP was performed via increasing cerebral flow and increasing PCO2. If not successful, the SCP was to be switched to bilateral perfusion. Air bubble hits were recorded at the termination of SCP. A sonographic window was confirmed in all patients. Procedural success was 100%. The mean operative time was 298 ± 89 minutes. Adequate cross-filling was confirmed in 8 patients. In 1 patient, inadequate cross-filling was detected by TCD and an optimization of cerebral flow was necessary, which was successfully confirmed by TCD. There was no conversion to bilateral perfusion. Extensive air bubble hits were confirmed in 1 patient, who suffered a postoperative stroke. The 30-day mortality rate was 0. Conclusion: The TCD is feasible for cerebral perfusion monitoring in aortic surgery. It enables a confirmation of adequacy of cerebral perfusion strategy or the need for its optimization. Documentation of calcific or air-bubble hits might add insight into patients suffering postoperative neurological deficits.

  1. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China); Sun Fei [GE Healthcare China (China)], E-mail: Fei.sun@med.ge.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com

    2009-04-15

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  2. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    International Nuclear Information System (INIS)

    Fan Li; Liu Shiyuan; Sun Fei; Xiao Xiangsheng

    2009-01-01

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  3. Study of lung perfusion in colagenosis

    Energy Technology Data Exchange (ETDEWEB)

    Macedo de Carvalho, A C; Calegaro, J U.M. [Fundacao Hospitalar do Distrito Federal, Distrito Federal (Brazil). Unidade de Medicina Nuclear

    1982-07-01

    The lung involvement in the various types of colagenosis has been widely described in the literature. However, the study of lung perfusion utilizing radionuclides has been only mentioned in a few papers. With the intention of ascertaining the importance of the lung perfusion scanning in colagenosis, ten cases were studied, seven of which were females and three males, with the following pathologies: 4 rheumatoid arthritis, 4 systemic lupus eritematosous, 1 scleroderma and 1 scleroderma plus dermatomyositis. The ages of the patients varied from 20 to 73 years, and the duration of the disease from 1 month to 39 years. The lung scanning showed perfusion defects in 100% of the cases, not related with the type of colagenosis, duration of the disease, sex or age. On the other hand, the X rays study showed alterations in only 2 patients (20% of the cases). The ventilatory and respiratory functions were tested on 7 patients showing alteration (mixed pattern with predominance of the restrictive factor) in only one (14.3%), while the other patients were normal (85.7%). The importance of the lung perfusion scanning study in all patients with collagen vascular diseases is emphasized.

  4. Study of lung perfusion in colagenosis

    International Nuclear Information System (INIS)

    Macedo de Carvalho, A.C.; Calegaro, J.U.M.

    1982-01-01

    The lung involvement in the various types of colagenosis has been widely described in the literature. However, the study of lung perfusion utilizing radionuclides has been only mentioned in a few papers. With the intention of ascertaining the importance of the lung perfusion scanning in colagenosis, ten cases were studied, seven of which were females and three males, with the following pathologies: 4 rheumatoid arthritis, 4 systemic lupus eritematosous, 1 scleroderma and 1 scleroderma plus dermatomyositis. The ages of the patients varied from 20 to 73 years, and the duration of the disease from 1 month to 39 years. The lung scanning showed perfusion defects in 100% of the cases, not related with the type of colagenosis, duration of the disease, sex or age. On the other hand, the X rays study showed alterations in only 2 patients (20% of the cases). The ventilatory and respiratory functions were tested on 7 patients showing alteration (mixed pattern with predominance of the restrictive factor) in only one (14.3%), while the other patients were normal (85.7%). The importance of the lung perfusion scanning study in all patients with collagen vascular diseases is emphasized. (author) [es

  5. Unilateral phrenic nerve stimulation for neurogenic hypoventilation in Arnold Chiari malformation

    Directory of Open Access Journals (Sweden)

    Nitin Garg

    2013-01-01

    Full Text Available Long- term ventilator dependence in patients with neurogenic hypoventilation is associated with significant morbidity and restricts mobility. Diaphragmatic pacing by phrenic nerve stimulation (PNS is a viable alternative. This is a case report of patient with Arnold-Chiari malformation with extensive syrinx who had neurogenic hypoventilation during sleep even after foramen magnum decompression and resolution of the syrinx. Unilateral PNS was done using spinal cord stimulator. With intermittent stimulation for 8 h while asleep, patient could be weaned off the ventilator completely. At 2 years follow- up, patient is ambulant and has returned to his routine activities. PNS is a good treatment tool in patients with neurogenic hypoventilation. Spinal cord stimulator can be used with optimal results. This is first such reported case of using spinal cord stimulator for PNS from India.

  6. Demonstration of cerebral abnormalities in cocaine abusers with SPECT perfusion brain scans

    International Nuclear Information System (INIS)

    Nagel, J.S.; Tumeh, S.S.; English, R.J.; Moore, M.; Lee, V.W.; Holman, L.B.

    1989-01-01

    This paper reports I-123 isopropyl iodoamphetamine (IMP) single-photon emission CT (SPECT) brain scans performed on cocaine users to investigate the effects of cocaine on the cerebral perfusion in a manner similar to previous CT, angiographic and positron-emission tomographic (PET) studies. Ten asymptomatic or mildly symptomatic cocaine users, two users with major neurovascular complications, and five normal subjects were studied with IMP SPECT. Rotating-brain images of the cerebral IMP uptake were displayed by using a distance-weighted surface-projection technique and were visually analyzed for focal cortical perfusion deficits. Eleven cocaine users had multiple scattered cortical IMP defects. Frontal lobe defects were most prominent. One user had confluent defects resembling swiss cheese. Concurrent CT scans available in nine patients were negative in seven and showed infarcts in two. No similar focal findings were visible in normals

  7. Evaluation of mosaic pattern areas in HRCT with Min-IP reconstructions in patients with pulmonary hypertension: Could this evaluation replace lung perfusion scintigraphy?

    International Nuclear Information System (INIS)

    Rossi, A.; Attinà, D.; Borgonovi, A.; Buia, F.; De Luca, F.; Guidalotti, P.L.; Fughelli, P.; Galiè, N.; Zompatori, M.

    2012-01-01

    -segmental patchy defects, 5 with segmental defects) and homogeneous in LPS, in 5 cases inhomogeneous (1 with non-segmental patchy defects, 4 with segmental defects) in LPS images and homogeneous in Min-IP. In a general view, Min-IP reconstruction without contrast-medium showed a sensitivity of 100% and specificity of 96.1%, positive predictive value (PPV) of 92.3% and negative predictive value (NPV) of 100%, to recognize a pattern of lung attenuation inhomogeneous with segmental defects correspondent to a chronic thromboembolic condition, no false negative cases and three false positive cases; on the other hand LPS, on its own, showed a sensitivity of 91.67% and specificity of 93.51%, positive predictive value (PPV) of 86.84% and negative predictive value (NPV) of 96%, 3 false negative cases and 5 false positive cases. Conclusion: Min-IP obtained in HRCT without contrast-medium and in CTPA were equivalent. Min-IP images generally showed a higher sensitivity and specificity than LPS in the evaluation of lung perfusion regarding patients with pulmonary hypertension caused by different etiology, particularly in CTEPH patients. These results can be completed with the evaluation of HRCT and CTPA basal scans, providing more informations than ventilation/perfusion lung scintigraphy. HRCT images integrated by Min-IP reconstruction can represent the first step in the diagnostic algorithm of patients affected by dyspnoea and pulmonary hypertension of unknown causes, reserving the use of contrast-medium only in selected patients and reducing the patients’ X-ray-exposition.

  8. Influence of ocular perfusion pressure fluctuation on glaucoma

    Directory of Open Access Journals (Sweden)

    Min-Zi Ren

    2015-12-01

    Full Text Available AIM:To investigate the influence of ocular perfusion pressure fluctuation on glaucoma. METHODS:Forty patients with primary open angle glaucoma from January 2013 to June 2015 in our hospital were used as observation group and 40 families were used as control group. Circadian fluctuation of intraocular pressure, blood pressure and ocular perfusion pressure in 24h were determined to obtain systolic ocular perfusion pressure(SOPP, diastolic ocular perfusion pressure(DOPPand mean ocular perfusion pressure(MOPP. Pearson linear correlation was used to analyze the correlation of circadian MOPP fluctuation with cup-disc ratio, mean defect(MDand the picture standard deviation(PSD. RESULTS:The fluctuation of MOPP, SOPP and DOPP of observation group were significantly higher than those of control group(Pr=-0.389, 95%CI:-0.612~-0.082; P=0.011, was positively correlated with PSD(r=0.512, 95%CI:0.139 ~0.782; P=0.008; no correlation was found between it and the vertical cup-disc ratio(r=0.115, 95%CI:0.056~0.369; P=0.355. CONCLUSION:Ocular perfusion pressure fluctuations in patients with primary open angle glaucoma may reflect the severity of the disease and may make the situation aggravating. Therefore through perfusion pressure monitor in 24h may help us understand the ocular blood flow and the development of primary open-angle glaucoma.

  9. Evaluation of regional pulmonary ventilation by videodensitometry using a new X-ray image processor

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Kanai, Hisakata; Handa, Kenjiro; Takizawa, Masaomi

    1988-01-01

    A new video image processing device has been produced in order to assess regional pulmonary ventilation. This device consists of a microcomputer, digital frame memory, digitizer, videomonitor, joystick and videotape recorder. The changing radiographic density of the lungs during deep respiration and forced expiration is recorded by the videotape recorder, which is connected to an image intensifier television system. This device allows the examining physician to place 6 rectangular windows of variable size over any portion of the video image using the joystick, and to measure the brightness level within these windows simultaneously. It is very characteristic that the video-densitometric curve and marks of the windows are superimposed on the frozen final frame of the sampled images. By this procedure, fair videodensigrams were obtained in various respiratory diseases, and reduction of ventilatory amplitude was shown in the hypoventilatory regions. The joint use of video-densitometry and perfusion lung scintigraphy provided helpful information concerning the regional ventilation/perfusion relationship. The videodensitometry of the lung the new X-ray image processor offers routine screening evaluation of regional pulmonary ventilation abnormalities over the entire video image of the lungs without more effort required of the patients. (author)

  10. Persistence of ventilatory defect after resolution of pulmonary interstitial emphysema in a preterm baby.

    Science.gov (United States)

    Filho, Luiz Vicente Ferreira da Silva; Rossi, Felipe De Souza; Deutsch, Alice d'Agostini; Yagui, Ana Cristina Zanon; Timenetsky, Karina; Rebello, Celso de Moura

    2010-07-01

    Pulmonary interstitial emphysema is a common complication of mechanical ventilation in preterm babies. We report a case of severe unilateral pulmonary interstitial emphysema in a premature newborn, treated with high-frequency oscillatory ventilation, lateral decubitus positioning and selective intubation. After complete radiological resolution of the pulmonary emphysema in the left lung, the patient was studied by electrical impedance tomography and a marked reduction of ventilation was identified in the left lung despite radiological resolution of the cysts. This finding indicates that functional abnormalities may persist for longer periods after radiologic resolution of such lesions.

  11. Radioaerosol Inhalation Lung Scan in Pulmonary Emphysema

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Jeong Soo; Park, Yong Ha; Kyo, Chung Soo; Bahk, Yong Whee [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1990-07-15

    emphysema was diffuse (6/21), discrete(6/21), intermediate (3/21), or combined (6/21). In 12 patients studied also with perfusion scans, perfusion defects matched closely with ventilation defects in location and configuration. But the size of the ventilation defects was generally larger than the perfusion defects. In all four patients treated with bronchodilators, the follow-up study demonstrated decrease in abnormal of radioaerosol deposition in the central airway with improvement of ventilation defects. RII was useful technique for the evaluation of regional ventilatory abnormality and the effects of treatment with bronchodilators in pulmonary emphysema.

  12. Radioaerosol Inhalation Lung Scan in Pulmonary Emphysema

    International Nuclear Information System (INIS)

    Jeon, Jeong Soo; Park, Yong Ha; Chung Soo Kyo; Bahk, Yong Whee

    1990-01-01

    diffuse (6/21), discrete(6/21), intermediate (3/21), or combined (6/21). In 12 patients studied also with perfusion scans, perfusion defects matched closely with ventilation defects in location and configuration. But the size of the ventilation defects was generally larger than the perfusion defects. In all four patients treated with bronchodilators, the follow-up study demonstrated decrease in abnormal of radioaerosol deposition in the central airway with improvement of ventilation defects. RII was useful technique for the evaluation of regional ventilatory abnormality and the effects of treatment with bronchodilators in pulmonary emphysema.

  13. Regional study of ventilation with inhaled xenon 133 in children

    International Nuclear Information System (INIS)

    Gaultier, C.; Mensch, B.; Gerbeaux, J.

    1975-01-01

    A regional exploration of pulmonary ventilation in a population of 104 infants and children by a study of distribution and washout of xenon 133 inhaled with rebreathing is carried out. The results are expressed by photographs (gamma-camera) and time-activity curves. The indications for regional exploration were oriented by the existence on the straight X-ray film of a localised ventilation disorder (a hyperlucent area or an opacity). This study permitted physiopathological analysis and guided endobronchial examinations. The functional results obtained, complete and explain other methods of exploration of lung function by spirography, ventilatory mechanics, transthoracic electrical measurements and study of lung perfusion with technetium 99m [fr

  14. Optimizing Oxygenation in the Mechanically Ventilated Patient: Nursing Practice Implications.

    Science.gov (United States)

    Barton, Glenn; Vanderspank-Wright, Brandi; Shea, Jacqueline

    2016-12-01

    Critical care nurses constitute front-line care provision for patients in the intensive care unit (ICU). Hypoxemic respiratory compromise/failure is a primary reason that patients require ICU admission and mechanical ventilation. Critical care nurses must possess advanced knowledge, skill, and judgment when caring for these patients to ensure that interventions aimed at optimizing oxygenation are both effective and safe. This article discusses fundamental aspects of respiratory physiology and clinical indices used to describe oxygenation status. Key nursing interventions including patient assessment, positioning, pharmacology, and managing hemodynamic parameters are discussed, emphasizing their effects toward mitigating ventilation-perfusion mismatch and optimizing oxygenation. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Hyperventilation, cerebral perfusion, and syncope

    DEFF Research Database (Denmark)

    Immink, R V; Pott, F C; Secher, N H

    2014-01-01

    dioxide (PaCO2) and oxygen (PaO2) partial pressures so that hypercapnia/hypoxia increases and hypocapnia/hyperoxia reduces global cerebral blood flow. Cerebral hypoperfusion and TLOC have been associated with hypocapnia related to HV. Notwithstanding pronounced cerebrovascular effects of PaCO2...... the contribution of a low PaCO2 to the early postural reduction in middle cerebral artery blood velocity is transient. HV together with postural stress does not reduce cerebral perfusion to such an extent that TLOC develops. However when HV is combined with cardiovascular stressors like cold immersion or reduced...... cardiac output brain perfusion becomes jeopardized. Whether, in patients with cardiovascular disease and/or defect, cerebral blood flow cerebral control HV-induced hypocapnia elicits cerebral hypoperfusion, leading to TLOC, remains to be established....

  16. Assessment of non-typical worsening of myocardial perfusion in rest in comparison to stress in 99mTc-MIBI SPECT studies. Preliminary report

    International Nuclear Information System (INIS)

    Dabrowski, A.; Szumilak, B.; Wnuk, J.; Konieczna, S.; Teresinska, A.

    2002-01-01

    Worsening of regional rest perfusion in comparison to stress perfusion, observed in a few percentage of myocardial perfusion 99m Tc-MIBI SPECT studies, does not have an easy clinical interpretation. Also, no reports evaluating the relationship between worsening and technical SPECT study conditions are available. The goal of our study is: 1) to assess the reproducibility of this non-typical effect - by repeating the rest study on separate day after new MIBI injection; 2) to assess reproducibility of this effect in rest perfusion images performed at different time points after one MIBI injection; 3) to propose the most probable clinical explanation for this effect. Up to now, 20 patients (100 predicted altogether) with rest perfusion worsening in routine stress-rest 99m Tc-MIBI SPECT perfusion imaging were studied. The group was clinically in homogeneous (7 patients with suspected coronary artery disease (CAD), 4 patients with CAD and no myocardial infarction (MI), 8 patients after MI, and 1 patient with developmental anomaly). Within 14 days, rest study was repeated, with data acquisition performed at 1 h and 3 hrs after MIBI injection. Regional myocardial perfusion was evaluated qualitatively, in 17 segments of the LV and compared among stress and all the three rest (BAD-I, BAD-II, BAD-III) studies. In 175 segments there was perfusion worsening in at least one of the three rest studies. In the highest percentage of these segments (n=53, 30%, ), worsening was present in all rest studies. Among stress defects with perfusion worsening in BAD-I, the highest percentage (55%, ) presented worsening also in BAD-II (performed after separate injection of MIBI, but like in BAD-I also 1 h after injection), significantly lower percentage - persistent defect in BAD-II (25%, ), and some smaller percentage - transient defect in BAD-II (20%, ). In segments with perfusion worsening present in one of the rest studies, our preliminary results show: 1) the highest probability of

  17. Two consecutive levels of unilateral cervical spondylolysis on opposite sides

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Kyeong Hwa; Kim, Seon Jeong; KIm Ok Hwa; Kim, Seung Ho; Lee, Kwang Hwi; Beak, Hye Jin; Lee, Ye Daun [Dept. of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan (Korea, Republic of); Cha, Yoon Ki [Dept. of Radiology, Dongguk University College of Medicine, Ilsan Hospital, Goyang (Korea, Republic of)

    2015-09-15

    Cervical spondylolysis, with or without spondylolisthesis, is a rare condition defined as a corticated cleft between the superior and inferior articular facets of the articular pillar. The defect occurs predominantly at C6, and is usually bilateral in up to two-thirds of cases. Multilevel involvement is uncommon, however, to date, no case of two consecutive levels of unilateral cervical spondylolysis on opposite sides has been reported. Here, we report a rare case of a patient affected by two consecutive levels of unilateral cervical spondylolysis at C5 and C6 on opposite sides in a 19-year-old male complaining of neck pain.

  18. Two consecutive levels of unilateral cervical spondylolysis on opposite sides

    International Nuclear Information System (INIS)

    Ryu, Kyeong Hwa; Kim, Seon Jeong; KIm Ok Hwa; Kim, Seung Ho; Lee, Kwang Hwi; Beak, Hye Jin; Lee, Ye Daun; Cha, Yoon Ki

    2015-01-01

    Cervical spondylolysis, with or without spondylolisthesis, is a rare condition defined as a corticated cleft between the superior and inferior articular facets of the articular pillar. The defect occurs predominantly at C6, and is usually bilateral in up to two-thirds of cases. Multilevel involvement is uncommon, however, to date, no case of two consecutive levels of unilateral cervical spondylolysis on opposite sides has been reported. Here, we report a rare case of a patient affected by two consecutive levels of unilateral cervical spondylolysis at C5 and C6 on opposite sides in a 19-year-old male complaining of neck pain

  19. High-resolution imaging of pulmonary ventilation and perfusion with {sup 68}Ga-VQ respiratory gated (4-D) PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Callahan, Jason [Centre for Molecular Imaging, Peter MacCallum Cancer Centre, East Melbourne, VIC (Australia); Hofman, Michael S. [The University of Melbourne, Department of Medicine, Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne, VIC (Australia); Siva, Shankar [The University of Melbourne, Peter MacCallum Cancer Centre, Department of Radiation Oncology, East Melbourne, VIC (Australia); The University of Melbourne, Sir Peter MacCallum Department of Oncology, East Melbourne, VIC (Australia); Kron, Tomas [The University of Melbourne, Sir Peter MacCallum Department of Oncology, East Melbourne, VIC (Australia); The University of Melbourne, Peter MacCallum Cancer Centre, Department of Physical Sciences, East Melbourne, VIC (Australia); Schneider, Michal E. [Monash University, Department of Medical Imaging and Radiation Science, Clayton, VIC (Australia); Binns, David; Eu, Peter [Peter MacCallum Cancer Centre, Centre for Cancer Imaging, East Melbourne, VIC (Australia); Hicks, Rodney J. [The University of Melbourne, Sir Peter MacCallum Department of Oncology, Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne, VIC (Australia)

    2014-02-15

    Our group has previously reported on the use of {sup 68}Ga-ventilation/perfusion (VQ) PET/CT scanning for the diagnosis of pulmonary embolism. We describe here the acquisition methodology for {sup 68}Ga-VQ respiratory gated (4-D) PET/CT and the effects of respiratory motion on image coregistration in VQ scanning. A prospective study was performed in 15 patients with non-small-cell lung cancer. 4-D PET and 4-D CT images were acquired using an infrared marker on the patient's abdomen as a surrogate for breathing motion following inhalation of Galligas and intravenous administration of {sup 68}Ga-macroaggregated albumin. Images were reconstructed with phase-matched attenuation correction. The lungs were contoured on CT and PET VQ images during free-breathing (FB) and at maximum inspiration (Insp) and expiration (Exp). The similarity between PET and CT volumes was measured using the Dice coefficient (DC) comparing the following groups; (1) FB-PET/CT, (2) InspPET/InspCT, (3) ExpPET/Exp CT, and (4) FB-PET/AveCT. A repeated measures one-way ANOVA with multiple comparison Tukey tests were performed to evaluate any difference between the groups. Diaphragmatic motion in the superior-inferior direction on the 4-D CT scan was also measured. 4-D VQ scanning was successful in all patients without additional acquisition time compared to the nongated technique. The highest volume overlap was between ExpPET and ExpCT and between FB-PET and AveCT with a DC of 0.82 and 0.80 for ventilation and perfusion, respectively. This was significantly better than the DC comparing the other groups (0.78-0.79, p < 0.05). These values agreed with a visual inspection of the images with improved image coregistration around the lung bases. The diaphragmatic motion during the 4-D CT scan was highly variable with a range of 0.4-3.4 cm (SD 0.81 cm) in the right lung and 0-2.8 cm (SD 0.83 cm) in the left lung. Right-sided diaphragmatic nerve palsy was observed in 3 of 15 patients. {sup 68}Ga-VQ 4-D

  20. Unilateral cleft lip and palate: Simultaneous early repair of the nose, anterior palate and lip

    Science.gov (United States)

    Laberge, Louise Caouette

    2007-01-01

    Unilateral cleft lip and palate is a defect involving the lip, nose and maxilla. These structures are inter-related, and simultaneous early correction of all the aspects of the defect is necessary to obtain a satisfactory result that will be maintained with growth. The surgical technique combining various procedures is presented and compared with previously published reports. PMID:19554125

  1. Drainage of pleural effusion improves diaphragmatic function in mechanically ventilated patients.

    Science.gov (United States)

    Umbrello, Michele; Mistraletti, Giovanni; Galimberti, Andrea; Piva, Ilaria R; Cozzi, Ottavia; Formenti, Paolo

    2017-03-01

    Pleural effusion adversely affects the pressuregenerating capacity of the diaphragm. It uncouples the lung and chest wall, which may result in diaphragmatic dysfunction. Information on the effects of effusion drainage on diaphragmatic function is limited, but several studies report relief of dyspnoea after drainage, which was attributed to improved diaphragmatic mechanics, even if this issue was never formally addressed. To investigate the effect of drainage of unilateral pleural effusion on diaphragmatic function. In a prospective twostep protocol (at baseline and after drainage of effusion), we conducted a spontaneous breathing trial in fourteen critically ill, mechanically ventilated patients undergoing pressure support ventilation. We used ultrasonography of the ipsilateral hemidiaphragm to evaluate and record respiratory displacement and thickening during tidal and maximal breathing efforts. We recorded and analysed airway pressures, respiratory system compliance, vital capacity, indices of respiratory effort and arterial blood gases. After drainage of the effusion, the respiratory rate decreased and tidal volume increased, but haemodynamic parameters were unaffected and oxygenation levels showed a non-significant increase. Drainage was associated with significant decreases in indices of respiratory drive and the maximal pressure generated by the respiratory muscles, as well as an increased compliance of the respiratory system. Diaphragmatic displacement and thickening significantly increased after drainage. We found there was a significant correlation between the volume of the effusion drained and the increase in tidal diaphragmatic thickening. Drainage of a unilateral pleural effusion during weaning from mechanical ventilation improves diaphragmatic contractile activity and respiratory system performance.

  2. Evaluation of Pulmonary Perfusion Scan in Heart Disease

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J T; Kim, C K; Park, C Y; Choi, B S [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1973-09-15

    Pulmonary perfusion scan with radioactive {sup 113m}In-iron hydroxide particle was performed in the 25 cases of heart disease which had been diagnosed by cardiac catheterization prior to surgery from July, 1972 to July, 1973 at the Department of Radiology and Nuclear Medicine, Yonsei Medical College. It consists of 7 mitral stenosis, 2 mitral insufficiency, 1 aortic insufficiency, 3 atrial septal defect, 5 ventricular septal defect, 2 patent ductus arteriosus, 1 transposition of great vessel and 4 Tetralogy of Fallot. Findings of pulmonary perfusion scan in relation to hemodynamic data of cardiac catheterization were examined. 1) Out of 10 cases of acquired valvular heart disease, In 6 cases of stenosis and 1 case of aortic insufficiency, radioactivity was increased at both upper lung. This finding is noted when pulmonary wedge or venous pressure was elevated above 22 mmHg and arterial systolic pressure above 33 mmHg. 2) Out of 15 cases of congenital heart disease. In almost all cases of artial septal defect and ventricular septal defect except 2 cases, radioactivity was even at both entire lung. In 2 cases of patent ductras arteriosus, radioactivity was decreased especially at the left lung. It is observed that in acyanotic congenital heart disease, radioactivity of lung is not related with pulmonary arterial pressure. In 3 cases of Tetralogy of Fallot, radioactivity was even at both entire lung and in 2 of them, extrapulmonary radioactivity of liver or kidney which depends on size of defect and volume of right to left shunt reversible, was noted.

  3. Evaluation of Pulmonary Perfusion Scan in Heart Disease

    International Nuclear Information System (INIS)

    Lee, J. T.; Kim, C. K.; Park, C. Y.; Choi, B. S.

    1973-01-01

    Pulmonary perfusion scan with radioactive 113m In-iron hydroxide particle was performed in the 25 cases of heart disease which had been diagnosed by cardiac catheterization prior to surgery from July, 1972 to July, 1973 at the Department of Radiology and Nuclear Medicine, Yonsei Medical College. It consists of 7 mitral stenosis, 2 mitral insufficiency, 1 aortic insufficiency, 3 atrial septal defect, 5 ventricular septal defect, 2 patent ductus arteriosus, 1 transposition of great vessel and 4 Tetralogy of Fallot. Findings of pulmonary perfusion scan in relation to hemodynamic data of cardiac catheterization were examined. 1) Out of 10 cases of acquired valvular heart disease, In 6 cases of stenosis and 1 case of aortic insufficiency, radioactivity was increased at both upper lung. This finding is noted when pulmonary wedge or venous pressure was elevated above 22 mmHg and arterial systolic pressure above 33 mmHg. 2) Out of 15 cases of congenital heart disease. In almost all cases of artial septal defect and ventricular septal defect except 2 cases, radioactivity was even at both entire lung. In 2 cases of patent ductras arteriosus, radioactivity was decreased especially at the left lung. It is observed that in acyanotic congenital heart disease, radioactivity of lung is not related with pulmonary arterial pressure. In 3 cases of Tetralogy of Fallot, radioactivity was even at both entire lung and in 2 of them, extrapulmonary radioactivity of liver or kidney which depends on size of defect and volume of right to left shunt reversible, was noted.

  4. Lung ventilation-perfusion imbalance in pulmonary emphysema. Assessment with automated V/Q quotient SPECT

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Koike, Hiroaki; Iwanaga, Hideyuki; Tokuda, Osamu; Okada, Munemasa; Matsunaga, Naofumi

    2010-01-01

    Tc-99m-Technegas-macro-aggregated albumin (MAA) single photon emission computed tomography (SPECT)-derived ventilation (V)/perfusion (Q) quotient SPECT was used to assess lung V-Q imbalance in patients with pulmonary emphysema. V/Q quotient SPECT and V/Q profile were automatically built in 38 patients with pulmonary emphysema and 12 controls, and V/Q distribution and V/Q profile parameters were compared. V/Q distribution on V/Q quotient SPECT was correlated with low attenuation areas (LAA) on density-mask computed tomography (CT). Parameters of V/Q profile such as the median, standard deviation (SD), kurtosis and skewness were proposed to objectively evaluate the severity of lung V-Q imbalance. In contrast to uniform V/Q distribution on V/Q quotient SPECT and a sharp peak with symmetrical V/Q distribution on V/Q profile in controls, lung areas showing heterogeneously high or low V/Q and flattened peaks with broadened V/Q distribution were frequently seen in patients with emphysema, including lung areas with only slight LAA. V/Q distribution was also often asymmetric regardless of symmetric LAA. All the proposed parameters of V/Q profile in entire lungs of patients with emphysema showed large variations compared with controls; SD and kurtosis were significantly different from controls (P<0.0001 and P<0.001, respectively), and a significant correlation was found between SD and A-aDO2 (P<0.0001). V/Q quotient SPECT appears to be more sensitive to detect emphysematous lungs compared with morphologic CT in patients with emphysema. SD and kurtosis of V/Q profile can be adequate parameters to assess the severity of lung V-Q imbalance causing gas-exchange impairment in patients with emphysema. (author)

  5. Augmentation of limb perfusion and reversal of tissue ischemia produced by ultrasound-mediated microbubble cavitation.

    Science.gov (United States)

    Belcik, J Todd; Mott, Brian H; Xie, Aris; Zhao, Yan; Kim, Sajeevani; Lindner, Nathan J; Ammi, Azzdine; Linden, Joel M; Lindner, Jonathan R

    2015-04-01

    Ultrasound can increase tissue blood flow, in part, through the intravascular shear produced by oscillatory pressure fluctuations. We hypothesized that ultrasound-mediated increases in perfusion can be augmented by microbubble contrast agents that undergo ultrasound-mediated cavitation and sought to characterize the biological mediators. Contrast ultrasound perfusion imaging of hindlimb skeletal muscle and femoral artery diameter measurement were performed in nonischemic mice after unilateral 10-minute exposure to intermittent ultrasound alone (mechanical index, 0.6 or 1.3) or ultrasound with lipid microbubbles (2×10(8) IV). Studies were also performed after inhibiting shear- or pressure-dependent vasodilator pathways, and in mice with hindlimb ischemia. Ultrasound alone produced a 2-fold increase (Pultrasound power. Ultrasound-mediated augmentation in flow was greater with microbubbles (3- and 10-fold higher than control for mechanical index 0.6 and 1.3, respectively; Pultrasound and microbubbles by 70% (Pultrasound and ultrasound with microbubbles. In mice with unilateral hindlimb ischemia (40%-50% reduction in flow), ultrasound (mechanical index, 1.3) with microbubbles increased perfusion by 2-fold to a degree that was greater than the control nonischemic limb. Increases in muscle blood flow during high-power ultrasound are markedly amplified by the intravascular presence of microbubbles and can reverse tissue ischemia. These effects are most likely mediated by cavitation-related increases in shear and activation of endothelial nitric oxide synthase. © 2015 American Heart Association, Inc.

  6. Unsatisfactory hepatic perfusion after placement of the infusaid pump: Angiographic correlation

    International Nuclear Information System (INIS)

    Andrews, J.C.; Williams, D.M.; Cho, K.J.; Knol, J.A.; Wahl, R.L.; Ensminger, W.D.

    1988-01-01

    Complete perfusion limited to the liver is essential to the success of regional chemotherapy for hepatic malignancy. Thirty-three patients with unsatisfactory hepatic artery perfusion scintigrams after surgical placement of a pump and catheter system were evaluated with selective angiography (31 cases) or digital subtraction angiography (DSA) via the pump side port (six cases). The cause of the perfusion defect was hepatic artery thrombosis (14 cases), extrahepatic flow through collaterals (13 cases), misplaced catheter (three cases), short proper hepatic artery without adequate length for mixing (two cases), and undefined (one case). DSA findings were diagnostic in only two cases. Angiographic findings directed attempted correction in 22 of 33 cases

  7. Assessment of regional ventilation by continuous inhalation of radioactive krypton-81m.

    Science.gov (United States)

    Fazio, F; Jones, T

    1975-01-01

    A simple technique is described for producing high-quality functional images of regional ventilation during physiological tidal breathing of the inert gas 81mKr. These images are quickly obtained on a gamma-camera without the need of computerized systems for data acquisition and display and are directly comparable with those of perfusion obtained with 99mTc-labelled macroaggregates. The short time required for the procedure, its simplicity, and the extremely low absorbed-radiation dose enable serial images of ventilation to be obtained in multiple views. Images FIG. 2 FIG. 3 FIG. 4 PMID:1182453

  8. Assessment of anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema with breath-hold SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Iwanaga, Hideyuki; Hayashi, Noriko; Seto, Akiko; Matsunaga, Naofumi

    2008-01-01

    Anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema was assessed on deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images. Subjects were 38 patients with pulmonary emphysema and 11 non-smoker controls, who successfully underwent DIBrH and non-BrH perfusion SPECT using a dual-headed SPECT system during the period between January 2004 and June 2006. DIBrH SPECT was three-dimensionally co-registered with DIBrH CT to comprehend the relationship between lung perfusion defects and CT low attenuation areas (LAA). By comparing the appearance of lung perfusion on DIBrH with non-BrH SPECT, the correlation with the rate constant for the alveolar-capillary transfer of carbon monoxide (DLCO/VA) was compared between perfusion abnormalities on these SPECTs and LAA on CT. DIBrH SPECT provided fairly uniform perfusion in controls, but significantly enhanced perfusion heterogeneity when compared with non-BrH SPECT in pulmonary emphysema patients (P<0.001). The reliable DIBrH SPECT-CT fusion images confirmed more extended perfusion defects than LAA on CT in majority (73%) of patients. Perfusion abnormalities on DIBrH SPECT were more closely correlated with DLCO/VA than LAA on CT (P<0.05). DIBrH SPECT identifies affected lungs with perfusion abnormality better than does non-BrH SPECT in pulmonary emphysema. DIBrH SPECT-CT fusion images are useful for more accurately localizing affected lungs than morphologic CT alone in this disease. (author)

  9. Correlation of angina pectoris and perfusion decrease by collateral circulation in single-vessel coronary chronic total occlusion using myocardial perfusion single-photon emssion computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang Geon; Park, Ki Seong; Kang, Sae Ryung [Chonnam National University Hospital, Gwangju (Korea, Republic of); and others

    2016-03-15

    To evaluate the perfusion decrease in donor myocardium by collateral circulation and its correlation with angina pectoris in patients with chronic total occlusion (CTO) using myocardial perfusion single-photon emission computed tomography (MPS). Thirty-six patients with single-vessel CTO without any other stenosis were included. All patients underwent MPS and coronary angiography (CAG) within 2 months. Total 72 donor arteries were evaluated for the grades of collaterals to the CTO artery using the Rentrop grading system on CAG. Perfusion defects and perfusion scores in donor and CTO territories were analyzed on MPS. Myocardial perfusion of donor and CTO territories were evaluated according to the presence of angina pectoris and the grades of collateral circulation. When the CTO territory was ischemic, symptomatic patients showed higher summed difference scores in the CTO territory compared to asymptomatic patients (3.5 ± 2.4 vs. 1.5 ± 0.8 for symptomatic and asymptomatic groups respectively; p = 0.034). However, when the CTO territory was nonischemic, symptomatic patients showed higher summed stress scores (SSS, 4.3 ± 2.9 vs. 1.6 ± 1.2; p = 0.032) and summed rest scores (SRS, 4.2 ± 2.5 vs. 1.5 ± 1.1; p = 0.003) in the donor territories. On the per-vessel analysis, perfusion defects in donor territories were more frequent (0 % vs. 53 % vs. 86 % for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p < 0.001) and showed higher SSS (0.0 ± 0.0, 1.3 ± 1.6 and 2.1 ± 1.1 for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p = 0.001) and SRS (0.0 ± 0.0, 1.0 ± 1.4 and 1.7 ± 1.2; p = 0.003) at higher Rentrop grades, but their patterns were variable. Angina pectoris was related to either ischemia of the myocardium beyond CTO or a perfusion decrease in the donor myocardium. The perfusion decrease in donor myocardium positively correlated with the collateral grades.

  10. Late gadolinium uptake demonstrated with magnetic resonance in patients where automated PERFIT analysis of myocardial SPECT suggests irreversible perfusion defect

    International Nuclear Information System (INIS)

    Rosendahl, Lene; Blomstrand, Peter; Ohlsson, Jan L; Björklund, Per-Gunnar; Ahlander, Britt-Marie; Starck, Sven-Åke; Engvall, Jan E

    2008-01-01

    Myocardial perfusion single photon emission computed tomography (MPS) is frequently used as the reference method for the determination of myocardial infarct size. PERFIT ® is a software utilizing a three-dimensional gender specific, averaged heart model for the automatic evaluation of myocardial perfusion. The purpose of this study was to compare the perfusion defect size on MPS, assessed with PERFIT, with the hyperenhanced volume assessed by late gadolinium enhancement magnetic resonance imaging (LGE) and to relate their effect on the wall motion score index (WMSI) assessed with cine magnetic resonance imaging (cine-MRI) and echocardiography (echo). LGE was performed in 40 patients where clinical MPS showed an irreversible uptake reduction suggesting a myocardial scar. Infarct volume, extent and major coronary supply were compared between MPS and LGE as well as the relationship between infarct size from both methods and WMSI. MPS showed a slightly larger infarct volume than LGE (MPS 29.6 ± 23.2 ml, LGE 22.1 ± 16.9 ml, p = 0.01), while no significant difference was found in infarct extent (MPS 11.7 ± 9.4%, LGE 13.0 ± 9.6%). The correlation coefficients between methods in respect to infarct size and infarct extent were 0.71 and 0.63 respectively. WMSI determined with cine-MRI correlated moderately with infarct volume and infarct extent (cine-MRI vs MPS volume r = 0.71, extent r = 0.71, cine-MRI vs LGE volume r = 0.62, extent r = 0.60). Similar results were achieved when wall motion was determined with echo. Both MPS and LGE showed the same major coronary supply to the infarct area in a majority of patients, Kappa = 0.84. MPS and LGE agree moderately in the determination of infarct size in both absolute and relative terms, although infarct volume is slightly larger with MPS. The correlation between WMSI and infarct size is moderate

  11. Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects.

    Science.gov (United States)

    Trott, C M; Ouyang, J; El Fakhri, G

    2010-11-21

    Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two radionuclide signals. We consider a simultaneous rest (99m)Tc-sestamibi/(123)I-BMIPP imaging protocol in place of the commonly used sequential rest/stress (99m)Tc-sestamibi protocol. The theoretical precision with which the severity of a cardiac defect and the transmural extent of infarct can be measured is computed for simultaneous and sequential SPECT imaging, and their performance is compared for discriminating (1) degrees of defect severity and (2) sub-endocardial from transmural defects. We consider cardiac infarcts for which reduced perfusion and metabolism are observed. From an information perspective, simultaneous imaging is found to yield comparable or improved performance compared with sequential imaging for discriminating both severity of defect and transmural extent of infarct, for three defects of differing location and size.

  12. Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects

    International Nuclear Information System (INIS)

    Trott, C M; Ouyang, J; El Fakhri, G

    2010-01-01

    Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two radionuclide signals. We consider a simultaneous rest 99m Tc-sestamibi/ 123 I-BMIPP imaging protocol in place of the commonly used sequential rest/stress 99m Tc-sestamibi protocol. The theoretical precision with which the severity of a cardiac defect and the transmural extent of infarct can be measured is computed for simultaneous and sequential SPECT imaging, and their performance is compared for discriminating (1) degrees of defect severity and (2) sub-endocardial from transmural defects. We consider cardiac infarcts for which reduced perfusion and metabolism are observed. From an information perspective, simultaneous imaging is found to yield comparable or improved performance compared with sequential imaging for discriminating both severity of defect and transmural extent of infarct, for three defects of differing location and size.

  13. A comparison between ventilation/perfusion scintigraphy and multislice spiral CT in the diagnosis of chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Fang Wei; Wang Feng; He Zuoxiang; Lu Jinguo; Lv Bing; He Jianguo; Liu Zhihong

    2008-01-01

    Objective: Chronic thromboembolic pulmonary hypertension (CTEPH) is one of the important causes of pulmonary hypertension with poor prognosis. Several imaging techniques had been used to identify CTEPH. The aim of this study was to assess the reliability of ventilation/perfusion (V/Q) scintigraphy and multislice spiral CT pulmonary angiography (CTPA) in the diagnosis of chronic thromboembolic pulmonary hypertension, and the concordance rate (or 'agreement' as in the original article) between the two techniques. Methods: Forty-nine in-patients with pulmonary hypertension without history of con- genital heart disease, valvular heart disease and acute pulmonary embolism were included in this study. All these patients underwent V/Q scintigraphy as well as CTPA for detecting CTEPH. The final diagnosis was confirmed by pulmonary angiograpy. The results of V/Q scintigraphy and CTPA were compared with the χ 2 test. Results: The sensitivity, specificity and accuracy of V/Q scintigraphy in diagnosis of CTEPH was 100.0% (17/17), 71.9% (23/32) and 81.6% (40/49), respectively, and those of CTPA was 94.1% (16/17), 81.2% (26/32) and 85.7% (42/49), respectively. The concordance rate was 75.5% (37/49, Kappa=0.513), no statistically significant difference (χ 2 =0.75, P > 0.05 ) was found between V/Q scintigraphy and CTPA. Conclusion: Both V/Q scintigraphy and CTPA are reliable to diagnose CTEPH. (authors)

  14. Acute Parotitis as a Complication of Noninvasive Ventilation.

    Science.gov (United States)

    Alaya, S; Mofredj, Ali; Tassaioust, K; Bahloul, H; Mrabet, A

    2016-09-01

    Several conditions, including oropharyngeal dryness, pressure sores, ocular irritation, epistaxis, or gastric distension, have been described during noninvasive ventilation (NIV). Although this technique has been widely used in intensive care units and emergency wards, acute swelling of the parotid gland remains a scarcely reported complication. We describe herein the case of an 82-year-old man who developed unilateral parotitis during prolonged NIV for acute heart failure. Intravenous antibiotics, corticosteroids, and adjusting the mask laces' position allowed rapid resolution of clinical symptoms. © The Author(s) 2016.

  15. The role of perfusion computed tomography in the prediction of cerebral hyperperfusion syndrome.

    Directory of Open Access Journals (Sweden)

    Chien Hung Chang

    Full Text Available Hyperperfusion syndrome (HPS following carotid angioplasty with stenting (CAS is associated with significant morbidity and mortality. At present, there are no reliable parameters to predict HPS. The aim of this study was to clarify whether perfusion computed tomography (CT is a feasible and reliable tool in predicting HPS after CAS.We performed a retrospective case-control study of 54 patients (11 HPS patients and 43 non-HPS with unilateral severe stenosis of the carotid artery who underwent CAS. We compared the prevalence of vascular risk factors and perfusion CT parameters including regional cerebral blood volume (rCBV, regional cerebral blood flow (rCBF, and time to peak (TTP within seven days prior to CAS. Demographic information, risk factors for atherosclerosis, and perfusion CT parameters were evaluated by multivariable logistic regression analysis. The rCBV index was calculated as [(ipsilateral rCBV - contralateral rCBV/contralateral rCBV], and indices of rCBF and TTP were similarly calculated. We found that eleven patients had HPS, including five with intracranial hemorrhages (ICHs of whom three died. After a comparison with non-HPS control subjects, independent predictors of HPS included the severity of ipsilateral carotid artery stenosis, 3-hour mean systolic blood pressure (3 h SBP after CAS, pre-stenting rCBV index >0.15 and TTP index >0.22.The combination of severe ipsilateral carotid stenosis, 3 h SBP after CAS, rCBV index and TTP index provides a potential screening tool for predicting HPS in patients with unilateral carotid stenosis receiving CAS. In addition, adequate management of post-stenting blood pressure is the most important treatable factor in preventing HPS in these high risk patients.

  16. Correlation of the myocardial perfusion corrected by attenuation with the coronariography. Preliminary results; Correlacion de la perfusion miocardica corregida por atenuacion con la coronariografia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia C, S.E.; Garcia O, R. [Servicio de Medicina Nuclear, Centro Medico ABC, Campis Observatorio, IAP (Mexico)

    2005-07-01

    The attenuation that suffers the radiation in the soft tissues of the hinders the appropriate interpretation of the myocardial perfusion studies, for what have been implemented attenuation correction systems to reduce the attenuation for soft tissues and to provide myocardial perfusion images more accurate in the diagnosis of coronary illness. The objective was to evaluate the utility of an attenuation correction system (with source of Gadolinium 153) to minimize the devices that look like true defects of myocardial perfusion, caused by soft tissues (mammary tissue, thoracic wall, abdomen, left hemi diaphragm), and to compare those interpretations of the studies with the interpretations of the corresponding coronariographies. The method consists of 95 electronic files which were revised with the concept of heart catheterization, being identified 20 patients from the masculine sex to those that underwent coronariography among May 1999 and December 2002, and that they had study of myocardial perfusion in a maximum period of 3 months foresaw to the invasive procedure. (Author)

  17. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    International Nuclear Information System (INIS)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung; Ho, Shung-Tai

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  18. Relationship between regional ventilation and aerosol deposition in tidal breathing

    Energy Technology Data Exchange (ETDEWEB)

    Trajan, M.; Logus, J.W.; Enns, E.G.; Man, S.F.

    1984-07-01

    The regional distribution of the deposition of 1.2 micron particles of 99mTc sulfur colloid inhaled by tidal breathing was compared with the distribution of ventilation as measured by a 133Xe washout technique. Twelve subjects were studied, 6 with normal pulmonary function tests, 5 with air-flow limitation, and 1 with unilateral phrenic nerve paralysis. Both xenon and aerosol were inhaled at tidal volume by the subjects while seated upright. A large field gamma camera acquired posterior scans. Thirteen experiments were also done on 7 dogs: 1 with extrathoracic obstruction of the airway to 1 lung, and 12 with bronchoconstriction from the instillation of methacholine chloride into the airways of a lower lobe. Two of these dogs were studied with a gamma camera system, and the others were studied with a Picker multi-probe system. Both in humans and in dogs, an increase in time constant, which indicated a decrease in ventilation, was associated with an increase in peripheral aerosol deposition when normalized for ventilation. It is suggested that the increased residence time is responsible for the increased deposition in regions that received lesser ventilation.

  19. Relationship between regional ventilation and aerosol deposition in tidal breathing

    International Nuclear Information System (INIS)

    Trajan, M.; Logus, J.W.; Enns, E.G.; Man, S.F.

    1984-01-01

    The regional distribution of the deposition of 1.2 micron particles of 99mTc sulfur colloid inhaled by tidal breathing was compared with the distribution of ventilation as measured by a 133Xe washout technique. Twelve subjects were studied, 6 with normal pulmonary function tests, 5 with air-flow limitation, and 1 with unilateral phrenic nerve paralysis. Both xenon and aerosol were inhaled at tidal volume by the subjects while seated upright. A large field gamma camera acquired posterior scans. Thirteen experiments were also done on 7 dogs: 1 with extrathoracic obstruction of the airway to 1 lung, and 12 with bronchoconstriction from the instillation of methacholine chloride into the airways of a lower lobe. Two of these dogs were studied with a gamma camera system, and the others were studied with a Picker multi-probe system. Both in humans and in dogs, an increase in time constant, which indicated a decrease in ventilation, was associated with an increase in peripheral aerosol deposition when normalized for ventilation. It is suggested that the increased residence time is responsible for the increased deposition in regions that received lesser ventilation

  20. Thallium - 201 miocardial perfusion scintigraphy in patients with mitral valve prolapse, with and without coronary artery disease

    International Nuclear Information System (INIS)

    Moraes, A.G. de; Sousa, J.E.M.R.; Thom, A.F.; Martins, L.R.F.; Meneghelo, R.S.; Pimentel Filho, W.A.; Marioni Filho, H.; Gimenes, V.M.L.; Pontes Junior, S.C.

    1981-01-01

    Thirty patients with precordial pain and mitral valve prolapse diagnosed by cineangiography and M-mode echocardiography were submitted to Thallium-201 myocardial stress perfusion scintillography. They were divided into two groups: group I - eighteen patients with mitral valve prolapse and normal coronary arteries, of which ten presented positive exercise stress test (55.6%); eight patients had a negative exercise test. Thallium-201 myocardial stress perfusion scintillagraphy was normal in 14 (77.8%) patients, and four with positive stress perfursion scintillography, (three with inferior perfusion defects and one with a lateral one); group II - twelve patients with mitral valve prolapse and severe coronary artery disease (stenosis >= 60% in at least one main vessel of the coronary circulation), of which nine presented positive exercise stress test (75%) and three negative. Thallium-201 exercise myocardial perfusion scintillography was abnormal in nine (75%), six with stress induced ischemia and three with resting defect. Myocardial perfusion scintillography with Thallium-201 was more sensitive to detect the presence of coronary artery disease in patients with mitral valve prolapse (MVP) than the exercise stress test in spite of the fact that a small number of patients (22%) with MVP and normal coronary arteries exhibited abnormal myocardial stress perfusion during scintillography. (Author) [pt

  1. Unilateral retinitis pigmentosa occurring in an individual with a mutation in the CLRN1 gene.

    Science.gov (United States)

    Sim, Peng Yong; Jeganathan, V Swetha E; Wright, Alan F; Cackett, Peter

    2018-03-15

    This case report depicts the clinical course of a female patient with unilateral retinitis pigmentosa, who first presented at the age of 12 years. Fundus photography at the time revealed unilateral pigmentary retinopathy, which was associated with extinguished electroretinogram (ERG) signal. At 35 years of age, fundus examination revealed deterioration of pre-existing unilateral pigmentary retinopathy with progressive visual field defect detected on Goldmann visual field testing. ERG findings remained unchanged and multifocal ERG showed unilateral decrease in amplitude in the affected eye. The patient was referred for genetic counselling. Next-generation sequencing identified a deleterious heterozygous c.118T>G (p.Cys40Gly) mutation in the CLRN1 gene. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Evaluation of patients with coronary artery disease during exercise: the relation between extent of disease and perfusion deficit

    International Nuclear Information System (INIS)

    Hakki, A.H.; DePace, N.; Iskandrian, A.S.

    1984-01-01

    The purpose of this study was to assess the relation between the extent of coronary artery disease (CAD) and size of exercise-induced myocardial hypoperfusion in 79 patients with angiographically documented CAD. None of the patients had Q-wave myocardial infarction. Fifty patients had one-vessel disease, ten had two-vessel disease, and 19 patients had three-vessel or left main disease. From a scintigraphic functional standpoint, patients were classified into two groups: 28 patients (35%) had large perfusion defects and 51 patients (65%) had small defects. The size of the thallium-201 perfusion defect during exercise was assessed as the perimeter of the defect in each projection expressed as a percentage abnormality of the total left ventricular perimeter in that projection. The average abnormality from the three projections was used in the final analysis. Eleven patients with large defects (39%) had one-vessel disease and 12 patients with small defects (24%) had multivessel disease. Stepwise multivariate discriminate analysis identified the number of diseased vessels (F . 13.9), the change in systolic blood pressure from rest to exercise (F . 10.8), the exercise heart rate (F . 9.1), and exercise electrocardiographic response (F . 7.8) as significant associates of the size of the perfusion defect (predictive accuracy . 70%). We conclude that the size of hypoperfused myocardium during exercise is variable in patients with CAD. Discriminate analysis identified the extent of CAD, exercise heart rate, change in systolic pressure from rest to exercise, and exercise electrocardiographic response as significant associates of the size of the defect

  3. Prevalence of myocardial ischaemia as assessed with myocardial perfusion scintigraphy in patients with diabetes mellitus type 2 and mild anginal symptoms

    International Nuclear Information System (INIS)

    Wiersma, Jacobijne J.; Trip, Mieke D.; Piek, Jan J.; Tijssen, Jan G.P.; Verberne, Hein J.; Eck-Smit, Berthe L.F. van; Holt, Wik L. ten

    2006-01-01

    To determine the prevalence and predictors of reversible myocardial perfusion defects, indicative of myocardial ischaemia, in patients with mild, stable anginal complaints [Canadian Cardiovascular Society classification (CCS) I-II/IV] and diabetes mellitus type 2 (T2DM). A total of 329 patients with T2DM and stable, mild anginal symptoms (CCS I-II/IV) underwent myocardial perfusion scintigraphy. Perfusion images were assessed using a five-point (semi)-quantitative scoring system according to a 17-segment myocardial model. One-hundred and fifty-six (47%) patients showed reversible myocardial perfusion defects defined as a summed difference score of ≥3. Male gender [odds ratio (OR) 2.28, 95% CI 1.4-3.71, p=0.001], previous myocardial infarction (MI) without revascularisation (OR 3.04, 95% CI 1.28-7.24, p=0.01), and the use of two or more classes of anti-anginal medication (OR 2.36, 95% CI 1.48-3.76, p<0.001) were independent predictors for the presence of reversible defects. By contrast, lipid-lowering therapy reduced the possibility of reversible perfusion defects (OR 0.56, 95% CI 0.33-0.95, p=0.03). Approximately half of the patients with mild, stable angina pectoris and T2DM showed evidence of myocardial ischaemia. Male gender, previous MI and the use of anti-anginal medication were positive predictors and lipid-lowering therapy was a negative predictor for the results of the scintigraphic stress test. (orig.)

  4. Prevalence of myocardial ischaemia as assessed with myocardial perfusion scintigraphy in patients with diabetes mellitus type 2 and mild anginal symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Wiersma, Jacobijne J.; Trip, Mieke D.; Piek, Jan J.; Tijssen, Jan G.P. [Academic Medical Center, Department of Cardiology, Amsterdam (Netherlands); Verberne, Hein J.; Eck-Smit, Berthe L.F. van [Academic Medical Center Amsterdam, Department of Nuclear Medicine, Amsterdam (Netherlands); Holt, Wik L. ten [Amstelland Hospital, Department of Cardiology, Amstelveen (Netherlands)

    2006-12-15

    To determine the prevalence and predictors of reversible myocardial perfusion defects, indicative of myocardial ischaemia, in patients with mild, stable anginal complaints [Canadian Cardiovascular Society classification (CCS) I-II/IV] and diabetes mellitus type 2 (T2DM). A total of 329 patients with T2DM and stable, mild anginal symptoms (CCS I-II/IV) underwent myocardial perfusion scintigraphy. Perfusion images were assessed using a five-point (semi)-quantitative scoring system according to a 17-segment myocardial model. One-hundred and fifty-six (47%) patients showed reversible myocardial perfusion defects defined as a summed difference score of {>=}3. Male gender [odds ratio (OR) 2.28, 95% CI 1.4-3.71, p=0.001], previous myocardial infarction (MI) without revascularisation (OR 3.04, 95% CI 1.28-7.24, p=0.01), and the use of two or more classes of anti-anginal medication (OR 2.36, 95% CI 1.48-3.76, p<0.001) were independent predictors for the presence of reversible defects. By contrast, lipid-lowering therapy reduced the possibility of reversible perfusion defects (OR 0.56, 95% CI 0.33-0.95, p=0.03). Approximately half of the patients with mild, stable angina pectoris and T2DM showed evidence of myocardial ischaemia. Male gender, previous MI and the use of anti-anginal medication were positive predictors and lipid-lowering therapy was a negative predictor for the results of the scintigraphic stress test. (orig.)

  5. Myocardial function and perfusion in the CREST syndrome variant of progressive systemic sclerosis. Exercise radionuclide evaluation and comparison with diffuse scleroderma

    International Nuclear Information System (INIS)

    Follansbee, W.P.; Curtiss, E.I.; Medsger, T.A. Jr.; Owens, G.R.; Steen, V.D.; Rodnan, G.P.

    1984-01-01

    Myocardial function and perfusion were evaluated in 22 patients with progressive systemic sclerosis with the CREST syndrome using exercise and radionuclide techniques, pulmonary function testing, and chest roentgenography. The results were compared with a similar study of 26 patients with progressive systemic sclerosis with diffuse scleroderma. The prevalence of thallium perfusion abnormalities was similar in the groups with CREST syndrome and diffuse scleroderma, (64 percent versus 77 percent), but the defects were significantly smaller in the CREST syndrome (p less than 0.01). Reperfusion thallium defects in the absence of extramural coronary artery disease were seen in 38 percent of patients with diffuse scleroderma. This finding was not seen in any of the patients with the CREST syndrome. In diffuse scleroderma, abnormalities of both right and left ventricular function were related to larger thallium perfusion defects. In the CREST syndrome, abnormalities of left ventricular function were minor, were seen only during exercise, and were unrelated to thallium perfusion defects. Abnormal resting right ventricular function was seen in 36 percent of the patients with the CREST syndrome and was associated with an isolated decrease in diffusing capacity of carbon monoxide. It is concluded that the cardiac manifestations of the CREST syndrome are distinct from those found in diffuse scleroderma. Unlike diffuse scleroderma, abnormalities of left ventricular function in the CREST syndrome are minor and are unrelated to abnormalities of coronary perfusion. Right ventricular dysfunction in the CREST syndrome appears to be primarily related to pulmonary vascular disease

  6. Blood perfusion and pH monitoring in organs by laser-induced fluorescence spectroscopy

    Science.gov (United States)

    Vari, Sandor G.; Papazoglou, Theodore G.; Pergadia, Vani R.; Stavridi, Marigo; Snyder, Wendy J.; Papaioannou, Thanassis; Duffy, J. T.; Weiss, Andrew B.; Thomas, Reem; Grundfest, Warren S.

    1994-01-01

    Sensitivity of laser-induced fluorescence spectroscopy (LIFS) in detecting a change in tissue pH, and blood perfusion was determined. Rabbits were anesthetized, paralyzed, and mechanically ventilated. The arterial and venous blood supplies of the kidney were isolated and ligated to alter the perfusion. The femoral artery was cannulated to extract samples for blood gas analysis. A 308-nm XeCl was used as an excitation source. A 600 micrometers core diameter fiber was used for fluorescence acquisition, and the spectra analyzed by an optical multichannel analyzer (EG & G, OMA III). the corresponding intensity ratio R equals INADH / ICOLL was used as an index for respiratory acidosis. Blood perfusion was assessed using the following algorithm: (IELAS minus ICOLL) divided by (INADH minus ICOLL). The intensity ratio linearly decreased with the reduction of blood perfusion. When we totally occluded the artery the ratio decreased tenfold when compared to the ratio of a fully perfused kidney. Results of monitoring blood acidosis by laser-induced fluorescence spectroscopy shows a significant trend between pH and intensity ratio. Since all the slopes were negative, there is an obvious significant correlation between the pH and NADH.COLLAGEN RATIO. Blue-light-induced fluorescence measurements and ratio fluorometry is a sensitive method for monitoring blood perfusion and acidity or alkalinity of an organ.

  7. Sulpyrine inhalation challenge test monitored continuously by respiratory impedance and 81mKr ventilation image

    International Nuclear Information System (INIS)

    Suenaga, Naoto; Nakamura, Hitoshi; Shiratsuki, Natsuo; Nishioka, Yasuhiro; Kitada, Osamu; Sugita, Minoru

    1993-01-01

    Continuous changes of respiratory impedance by the oscillation method using Asthograph and 81m Kr ventilation image during saline and sulpyrine solution (100 mg/ml, 250 mg/ml) provocation were simultaneously measured in 15 adult asthmatics and 7 normal individuals. Estimation of airway obstruction by respiratory impedance using Asthograph was difficult during sulpyrine inhalation, since respiratory impedance increased gradually. In addition to the measurement of respiratory impedance, images of 81m Kr ventilation were also obtained to estimate the regional ventilatory distribution. Estimation of the airway obstruction was easily obtained. Another advantage of 81m Kr ventilation image is that it can estimate the regional ventilatory distribution. The site of airway obstruction provoked by sulpyrine was observed predominantly in the lower lung field. The results of our present study were as follows. In 3 patients, increase of respiratory impedance and defect of 81m Kr ventilation image were observed. Two cases in this group were clinically diagnosed as having aspirin-induced asthma. In 7 patients, a defect of 81m Kr ventilation image was observed, but no increase of respiratory impedance was observed. Five cases in this group could not be clinically diagnosed as having aspirin-induced asthma. In 5 patients, neither defect of 81m Kr ventilation image nor increase of respiratory impedance could be detected. These results suggest that 81m Kr ventilation image on sulpyrine inhalation challenge test is a useful method for evaluating regional ventilatory distribution, but should be further investigated for application to aspirin-induced asthma. (author)

  8. Optimization of perfusion studies using Atropine

    International Nuclear Information System (INIS)

    Alvarado, A.N.; Valle, V.M.; Montoya, M.J.; Eskenazi, E.S.; Montiel, M.L.; Cueto, C.C.

    2002-01-01

    The studies of myocardial perfusion require an adequate stress; exercise or pharmacological. Every day, more pharmacological studies are performed, specially in some group of patients (women, AMI, etc). There some drugs that are used for this purpose, as adenosine and dobutamine. However, their cost and the lack of availability and infrastructure in our country do not allow there routinely use. We performed dipyridamol as a pharmacological stress, however in some patients there is a doubt regarding if the pharmacological effect was adequate. Atropine is a drug that is frequently used for different purpose and it is well know its tachycardic response. We present and alternative technique, using dipyridamol-atropine as a protocol of stress perfusion study. Our goal was to correlate the standard dipyridamol -thallium perfusion study and the dipyridamol -atropine-perfusion in patients with chronic coronary disease. We evaluated 6 patients (5 males) with stable angina and chronic coronary disease. A standard dipyridamol-thallium study was performed in all of them. Dipyridamole was administered intravenously at a rate of 0.14 mg/kg/min over 6 min for a total of 0.84 mg/kg body weight. Blood pressure, heart rate, EKG and symptoms were monitored before, during and after the pharmacological infusion. Two minutes after the infusion was completed, the radiotracer was injected intravenously. In the next 6 months, without any modification of the clinical situation (symptoms and therapy) a new dipyridamol study was performed, using 1 mg of atropine after the administration of dipyridamol. There were no differences in the collateral effects and we observed and average increase of 30% in the heart rate in relation with the study using dipyridamol alone. The addition of atropine to the standard dipyridamol perfusion study is safe, cheaper and improved the detection of perfusion defects in patients with coronary artery disease

  9. Method for imaging pulmonary arterial hypoplasia

    International Nuclear Information System (INIS)

    Triantafillou, M.

    2000-01-01

    Full text: Pulmonary hypoplasia represents an incomplete development of the lung, resulting in the reduction of distended lung volume. This is associated with small or absent number of airway divisions, alveoli, arteries and veins. Unilateral pulmonary Hypoplasia is often asymptomatic and may be demonstrated as a hypodense lung on a chest X-ray. Computer Tomography (CT) scanning would show anatomical detail and proximal vessels. Magnetic Resonance Imaging (MRI) will show no more detail than which the CT scan has already demonstrated. It is, also, difficult to visualise collateral vessels from systemic and/or bronchial vessels on both these modalities. Pulmonary Angiography would give the definitive answer, but it is time consuming and has significant risks associated with the procedure. There are high costs associated with these modalities. Nuclear Medicine Ventilation/Perfusion (V/Q) scan performed on these patients would demonstrate diminished ventilation due to reduced lung volume and absence of perfusion to the hypoplastic lung. To date, we have performed V/Q lung scan on two children in our department. Both cases demonstrate diminished ventilation with no perfusion to the hypoplastic lung. Though the gold standard is Pulmonary Angiography, V/Q scanning is cost effective, less time consuming and a non invasive procedure that can be performed as an outpatient. It is accurate as it demonstrates absent lung perfusion, confirming the patient has pulmonary arterial hypoplasia. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  10. Characteristics of myocardial perfusion imaging and coronary artery angiography in patients of NIDDM complicated with AMI

    International Nuclear Information System (INIS)

    Zhao Peiqin; Zhao Jinhua; Qin Mingzhao; Dai HaoJie; Zhang Runwu; Xiao Fen

    2001-01-01

    Objective: To investigate the characteristic changes of myocardial perfusion imaging and coronary artery angiography in patients of acute myocardial infarction (AMI) with underlined type 2 diabetes mellitus. Methods: 25 type 2 diabetes mellitus patients were enrolled for having clinical manifestation of AMI. Ten inpatients with AMI of simple coronary heart disease origin were served as controls. All subjects underwent both myocardial perfusion imagings (resting and nitroglycerine invention) and coronary artery angiography. Results: Compared to controls (40%), type 2 diabetes mellitus + AMI group had higher rate of multivessel disease (60%). For type 2 diabetes mellitus + AMI patients, 129/400 segments (32.25%) showed fixed defect, 25/160 segments (15.62%) in controls. Conclusions: For type 2 diabetes mellitus + AMI group, myocardial perfusion defects are widely distributed and multivessel or severe stenosis is more often presented. Good correlation exists between abnormal segments and angiographic lesions in both the number of segments involved and the severity of the lesions. Radionuclide myocardial perfusion is therefore considered a useful screening test not inferior to angiography, especially for those who are not tolerant enough to undergoing angiography

  11. The Myocardial Perfusion Scintigraphy in Predicting Risk for Coronary Artery Disease in Patients with Anxiety and Depression Symptoms

    Directory of Open Access Journals (Sweden)

    Billur Çalışkan

    2016-06-01

    Full Text Available INTRODUCTION: An association between psychological factors and cardiovascular disease, has long been suspected. However it is not clear whether chest pain is caused by emotional distress or whether coronary spasms are caused by the onset of coronary artery disease (CAD. We aimed to predict the risk for CAD in patients referred to myocardial perfusion imaging (MPI with chest pain using depression, stress, and anxiety symptoms. METHODS: The emotional status of all patients was evaluated using the Hospital Anxiety and Depression Scale (HADS-A and HADS-D, the State and Trait Anxiety Inventory (STAI-1 and STAI-2, the Perceived Stress Scale (PSS, and the Anxiety Sensitivity Index-3 (ASI. Myocardial perfusion was measured using a 17-segment model and 5-point scoring system (0: normal perfusion; 4: no perfusion. RESULTS: MPI revealed reversible perfusion defects in 24 of 141 patients and no perfusion defects in 117 patients. The STAI-2 and HADS-A and HADS-D scores were significantly higher in patients with myocardial ischemia than in those without (STAI-2: 50.8 ± 7.5 vs. 46.3 ± 7.1, respectively; p = 0.008; HADS-A: 9.5 ± 3.9 vs. 7.8 ± 3.4, respectively; p = 0.033; HADS-D: 8.7 ± 3.0 vs. 7.3 ± 3.0, respectively; p = 0.05. Unadjusted correlation analysis showed that there was statistically significant correlation between reversible perfusion defects and anxiety scores (r=0.186, p= 0.029. DISCUSSION AND CONCLUSION: The patients with symptoms of depression and high-trait anxiety may be at higher risk of myocardial ischemia than patients without such symptoms. Thus, the emotional status of patients should be taken into consideration during clinical evaluation for CAD.

  12. Focal skin defect, limb anomalies and microphthalmia.

    NARCIS (Netherlands)

    Jackson, K.E.; Andersson, H.C.

    2004-01-01

    We describe two unrelated female patients with congenital single focal skin defects, unilateral microphthalmia and limb anomalies. Growth and psychomotor development were normal and no brain malformation was detected. Although eye and limb anomalies are commonly associated, clinical anophthalmia and

  13. Lung scan abnormalities in asthma and their correlation with lung function

    International Nuclear Information System (INIS)

    Vernon, P.; Burton, G.H.; Seed, W.A.; Charing Cross Hospital, London

    1986-01-01

    We have used asthma as a model of airways disease to test how well an automated, quantitative method of analysis of lung scans correlates with physiological measurements of disturbed lung function and gas exchange. We studies 25 asthmatics (age 16-73) of widely differing severity (forced expiratory volume in 1-s FEV 1 22%-123% of predicted value), who had airways tests, arterial blood gas analysis, and krypton-technetium lung scans within a short time of each other. In all patients with airways obstruction and in some with normal function during remission, scans showed the typical appearances of multiple defects of ventilation and perfusion. The severity of ventilation defects was assessed from the posterior view of the krypton scan compared to an age- and sex-matched normal range to yield an underventilation score. This correlated closely with the severity of airways obstruction as measured by forced expiratory manouevres. Ventilation and perfusion defects were usually imperfectly matched; the severity of this was computed using a subtraction method applied to the counts on the posterior krypton and technetium scans. The degree of mismatch was inversely related to the arterial partial pressure of oxygen (r=-0.86). The results suggest that computer scan analysis can provide usual functional information about the lung in airways disease. (orig.)

  14. The use of Kr-81m in ventilation imaging

    International Nuclear Information System (INIS)

    Pommet, R.; Therain, F.

    1982-01-01

    Radioactive gases are very useful in the study of pulmonary disorders because they allow an assessment of regional lung function. The most widely used radioactive gases are Xe-133 and, more recently, Kr-81m. This paper is a review of the physical characteristics of Kr-81m, its production from the parent Rb-81, the different methods to produce Rb-81, the different types of generators which can be used in hospitals, and the clinical applications of pulmonary ventilation imaging. The paper suggests that Kr-81m offers several advantages over previous methods that used Xe-133 due to its improved spatial resolution, its capacity to provide superimposable ventilation and perfusion images in multiple projections, and its total lung dose which is ten times lower than that of Xe-133

  15. Dynamic CT perfusion imaging of the myocardium: a technical note on improvement of image quality.

    Directory of Open Access Journals (Sweden)

    Daniela Muenzel

    Full Text Available OBJECTIVE: To improve image and diagnostic quality in dynamic CT myocardial perfusion imaging (MPI by using motion compensation and a spatio-temporal filter. METHODS: Dynamic CT MPI was performed using a 256-slice multidetector computed tomography scanner (MDCT. Data from two different patients-with and without myocardial perfusion defects-were evaluated to illustrate potential improvements for MPI (institutional review board approved. Three datasets for each patient were generated: (i original data (ii motion compensated data and (iii motion compensated data with spatio-temporal filtering performed. In addition to the visual assessment of the tomographic slices, noise and contrast-to-noise-ratio (CNR were measured for all data. Perfusion analysis was performed using time-density curves with regions-of-interest (ROI placed in normal and hypoperfused myocardium. Precision in definition of normal and hypoperfused areas was determined in corresponding coloured perfusion maps. RESULTS: The use of motion compensation followed by spatio-temporal filtering resulted in better alignment of the cardiac volumes over time leading to a more consistent perfusion quantification and improved detection of the extend of perfusion defects. Additionally image noise was reduced by 78.5%, with CNR improvements by a factor of 4.7. The average effective radiation dose estimate was 7.1±1.1 mSv. CONCLUSION: The use of motion compensation and spatio-temporal smoothing will result in improved quantification of dynamic CT MPI using a latest generation CT scanner.

  16. Pulmonary perfusion scintigraphy in children with chronic pulmonary damage: Preliminary results from application of the SPECT technique

    International Nuclear Information System (INIS)

    Lobo S, Gabriel; Ladron de Guevara H, David; Munoz G, Maria Angelica; Araya A, Fernando; Coll C, Claudia; Donoso R, Gilda; Jimenez J, Cesar; Perez R; Andres

    2003-01-01

    The aim was to describe lung perfusion SPECT (LPS) findings in children with chronic pulmonary damage. Material and Method: We revised 106 LPS of children (age:3.9 ± 3.3 yr) with chronic pulmonary damage, performed with a two headed gamma camera. The most common clinical diagnosis were adenovirus bronchopneumonia sequelae (ADV)(29%), unknown origin chronic pulmonary damage (UOPD) (21%), bronchopulmonary dysplasia (BPD)(15%), and chronic obstructed bronchitis (COB)(14%). Severity of pulmonary alterations were evaluated using a Score, which considered extent and type of lung involvement and differential pulmonary perfusion. Pattern of involvement and Score were correlated with diagnosis and gender. Results: Ninety one percent (96/106) of LPS were abnormal (62% boys). Fifty two (54%) showed bilateral alterations, being this finding (p:0.019) more frequent in boys. ADV group showed mainly a mixed bilateral pattern (35%), UOPD a focal unilateral pattern (32%), COB a diffuse unilateral pattern (33%), and BPD a normal pattern (25%). Miscellaneous and UOPD showed the highest score values, and BPD and COB the lowest ones. Conclusion: In this population, LPS is abnormal in high proportion, with some differential characteristics according gender and original diagnosis (au)

  17. Visceral Perfusion Scintigraphy with {sup 131}I-Labelled Albumin Macroaggregates

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, H.; Yamada, H.; Kitani, K.; Nagatani, M.; Takeda, T.; Migita, T.; Iio, M; Kameda, H. [University of Tokyo, Tokyo (Japan)

    1969-05-15

    The blood supply through the hepatic artery, superior mesenteric artery and portal vein to the visceral organs was studied in 60 cases of various hepatic disorders by scintigraphy after the selective introduction of {sup 131}I MAA by means of visceral arterial catheterization or percutaneous splenic puncture. A comparison of the radioactivities of the liver and the spleen after celiac arterial infusion (celiac perfusion scanning) indicated how much blood in the celiac artery was distributed to the two major arterial branches - the hepatic and splenic. Dominant perfusion was found through the hepatic branch in liver cirrhosis, whereas significantly dominant splenic blood perfusion was found in idiopathic non-cirrhotic portal hypertension. This remarkable contrast of the mode of celiac perfusion in two disorders indicated the etiological difference of these diseases. In malignant neoplasm of the liver, the dominant or exclusive celiac arterial perfusion was found in the tumour region. In these cases, liver scanning by the splenic injection of MAA (portal perfusion scanning) delineated the tumour region as a negative defect similar to the conventional {sup 198}Au colloid scanning. Consequently, from these two perfusion scintigrams the 'key and key-hole' pattern was demonstrated. It was concluded that a neoplastic lesion, primary or metastatic, has the predominant blood supply through the hepatic artery rather than through the portal vein. Celiac perfusion scanning of liver cystosis revealed multiple negative defects. This information was useful for differentiating a malignant tumour, which is usually impossible by conventional liver scanning. Celiac perfusion scanning was also useful for the diagnosis of arterial venous communication. In one case of liver .cancer with cirrhosis and another case with stomach varices, the arterial-v.enous communication was indicated by the appearance of the lung contour in the celiac perfusion scan. In both cases, the combined presence

  18. Perfusion imaging using rubidium-82 ((82)Rb) PET in rats with myocardial infarction

    DEFF Research Database (Denmark)

    Clemmensen, Andreas Ettrup; Ghotbi, Adam Ali; Bodholdt, Rasmus Poul

    2017-01-01

    Assessing myocardial perfusion using 82Rb-PET is emerging as a valuable clinical tool.1,2 The rapid decay (T½ = 76 s) allows for absolute quantification of both rest and stress perfusion within 30 minutes. In addition to evaluation of epicardial disease with perfusion defects, also evaluation...... of balanced coronary and small vessel disease is possible. For further evaluation of how 82Rb-PET can be used clinically, pre-clinical application of the method would be valuable. However, so far no data on the use of 82Rb-PET in small animals have been published nor has the use of 82Rb-PET, to the best...

  19. Application of Three-Class ROC Analysis to Task-Based Image Quality Assessment of Simultaneous Dual-Isotope Myocardial Perfusion SPECT (MPS)

    OpenAIRE

    He, Xin; Song, Xiyun; Frey, Eric C.

    2008-01-01

    The diagnosis of cardiac disease using dual-isotope myocardial perfusion SPECT (MPS) is based on the defect status in both stress and rest images, and can be modeled as a three-class task of classifying patients as having no, reversible, or fixed perfusion defects. Simultaneous acquisition protocols for dual-isotope MPS imaging have gained much interest due to their advantages including perfect registration of the 201Tl and 99mTc images in space and time, increased patient comfort, and higher...

  20. Subsequent investigation and management of patients with intermediate-category and - probability ventilation - perfusion scintigraphy

    International Nuclear Information System (INIS)

    Walsh, G.; Jones, D.N.

    2000-01-01

    The authors wished to determine the proportion of patients with intermediate-category and intermediate-probability ventilation-perfusion scintigraphy (IVQS) who proceed to further imaging for investigation of thromboembolism, to identify the defining clinical parameters and to determine the proportion of patients who have a definite imaging diagnosis of thromboembolism prior to discharge from hospital on anticoagulation therapy. One hundred and twelve VQS studies performed at the Flinders Medical Centre over a 9-month period were reported as having intermediate category and probability for pulmonary embolism. Medical case notes were available for review in 99 of these patients and from these the pretest clinical probability, subsequent patient progress and treatment were recorded. Eight cases were excluded because they were already receiving anticoagulation therapy. In the remaining 91 patients the pretest clinical probability was considered to be low in 25; intermediate in 30; and high in 36 cases. In total, 51.6% (n = 47) of these patients (8% (n = 2) with low, 66% (n = 20) with intermediate, and 69.4% (n = 25) with high pretest probability) proceeded to CT pulmonary angiography (CTPA) and/or lower limb duplex Doppler ultrasound (DUS) evaluation. Of the patients with IVQS results, 30.7% (n 28) were evaluated with CTPA. No patient with a low, all patients with a high and 46% of patients with an intermediate pretest probability initially received anticoagulation therapy. This was discontinued in three patients with high and in 12 patients with intermediate clinical probability prior to discharge from hospital. Overall, 40% of patients discharged on anticoagulation therapy (including 39% of those with a high pretest probability) had a positive imaging diagnosis of thromboembolism The results suggest that, although the majority of patients with intermediate-to-high pretest probability and IVQS proceed to further imaging investigation, CTPA is relatively underused in

  1. Groin defects seen at extra-peritoneal laparoscopic dissection during surgical treatment of athletic pubalgia.

    Science.gov (United States)

    Wikiel, Krzysztof J; Eid, George M

    2015-07-01

    Recently new disease process, often referred to as athletic pubalgia (AP), has been acknowledged by the medical community. The patients suffering from this ailment present with unilateral or bilateral chronic groin pain associated with physical activity without a clear diagnosis of a groin hernia. Though physical therapy and medical treatments are considered first line remedies, some believe that surgical treatment may have better, quicker, and more durable outcomes and procedures aimed at groin reinforcement seem to relieve most of symptoms in the majority of the patients. Despite many surgeons consistently noting rectus insertion or adductor thinning, multiple hernia defects are often seen during dissections and the clinical significance of these findings is still not known. Between 2007 and 2011, 40 patients underwent an extra-peritoneal laparoscopic reinforcement of rectus abdominals and insertion of adductor muscles for AP. All patients underwent wide and bilateral groin dissection and the findings were cataloged. All of the patients presented with groin defects upon wide dissection. Thirty-four patients (85%) presented with small bilateral indirect inguinal defects and 28 (70%) of these patients did not have any additional defects. Five patients (12.5%) were found to have only unilateral inguinal hernia defects. One patient presented with a small direct defect. In addition to these defects, five patients (12.5%) had additional unilateral femoral hernias, whereas no patient had solitary femoral hernia defects. AP is a new diagnostic entity with poorly understood etiology. It mostly affects young active adults, often involved in competitive sports and surgical methods may be most effective at achieving the cure. In our experience all of the patients presented with groin defects, though not all were the same. It is our belief that these defects, although likely not the only component, play a significant role in the pathophysiology of AP.

  2. Specific perfusion pattern in stress 201Tl myocardial scintigraphy of left main coronary artery disease

    International Nuclear Information System (INIS)

    Wakasugi, Shigetoshi; Shibata, Nobuhiko; Kobayashi, Tohru; Fudemoto, Yoshiyuki; Hasegawa, Yoshihisa; Nakano, Shunichi

    1986-01-01

    The usefulness of stress 201 Tl myocardial scintigraphy for identifying left main coronary artery disease was evaluated with data from 23 patients with 50% or more narrowing of the left main coronary artery and 56 patients with 75% or more narrowing of the major coronary arteries but without left main coronary artery involvement (no left main coronary artery disease). Quantitative evaluation of stress perfusion scintigrams in all five patients with narrowing of the left main coronary artery of 90% or more showed a characteristic perfusion pattern (left main pattern) of extensive homogeneous defect over the whole anterolateral segment and simultaneous defects in all radii of the high anteroseptal and high posterolateral segments. On the other hand, such a perfusion pattern was noted in only 1 of 18 patients with less than 90% stenosis of the left main coronary artery and in only 1 of 56 patients with no left coronary artery disease. (orig.)

  3. Assessment of lung ventilation by MR imaging: current status and future perspectives

    International Nuclear Information System (INIS)

    Kauczor, Hans-Ulrich; Hanke, Alexander; Beek, Edwin J.R. van

    2002-01-01

    The aim of this paper is to review the present status of novel MRI techniques as a new important instrument for functional ventilation imaging. The current status and future perspectives in research and clinical applications are summarized. Morphological lung imaging is based on chest radiography and computed tomography, whereas scintigraphy is used for ventilation imaging. During recent years, MRI has emerged as a new means for functional imaging of ventilation. Aerosolized contrast agents and oxygen are used in proton imaging, whereas non-proton imaging relies on fluorine compounds, such as sulfur hexafluoride and perfluorcarbons, or on hyperpolarized noble gases, such as helium-3 or xenon-129. All the gases are administered as inhaled ''contrast agents'' for imaging of the airways and airspaces. In general, straightforward images demonstrate the homogeneity of ventilation in a breath-hold and allow for determination of ventilated lung. The different properties of the different compounds enable the measurement of additional functional parameters. They comprise airspace size, regional oxygen partial pressure, and analysis of ventilation distribution, ventilation/perfusion ratios, and gas exchange, including oxygen uptake. Novel MRI techniques provide the potential for functional imaging of ventilation. The next steps include definition of the value and the potential of the different contrast mechanisms as well as determination of the significance of the functional information with regard to physiological research and patient management in chronic obstructive pulmonary disease and others. (orig.)

  4. Perfusion differences on SPECT and PWI in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Nuutinen, Juho; Liu, Yawu; Laakso, Mikko P.; Karonen, Jari O.; Vanninen, Esko J.; Kuikka, Jyrki T.; Aronen, Hannu J.; Vanninen, Ritva L.

    2009-01-01

    The purposes of the present study were to compare the flow defect volumes on perfusion-weighted magnetic resonance imaging (PWI) and 99m Tc-labeled ethylcysteinate dimer ( 99m Tc-ECD) single photon emission computed tomography (SPECT) at acute and subacute stages of ischemic stroke and to analyze the relationship between the detected flow defects on the two methods and neurological status and clinical outcomes. Perfusion defects on PWI and SPECT were measured within 48 h and on day 8 of the onset of stroke from 22 patients with their first-ever acute supratentorial ischemic stroke. The primary neurological status was evaluated prior to the imaging. Clinical outcome was assessed at 3 months after the onset of the stroke. The volumes of cerebral blood flow (CBF) defects did not differ between SPECT and PWI within the 48-h examinations. However, the volume of CBF defect was significantly larger on SPECT than on PWI on day 8 (p = 0.03). Within the 48-h examinations, the CBF defect volumes on SPECT and PWI were comparably related to the neurological status. On day 8, the CBF defect volume on SPECT showed higher correlation to the neurological status and more precisely predicted the clinical outcomes at 3 months than PWI. 99m TC-ECD-SPECT and PWI both have ability to detect cerebral hypoperfusion in patients with ischemic stroke but with some differences. The value of SPECT is more accurate in terms of the delayed outcome, such as prognosis and rehabilitation planning. (orig.)

  5. Perfusion differences on SPECT and PWI in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Nuutinen, Juho [Kuopio University Hospital, University of Kuopio, Department of Neurology, Kuopio (Finland); Liu, Yawu; Laakso, Mikko P. [Kuopio University Hospital, University of Kuopio, Department of Neurology, Kuopio (Finland); Kuopio University Hospital, University of Kuopio, Department of Clinical Radiology, P. O. Box 1777, Kuopio (Finland); Karonen, Jari O. [Mikkeli Central Hospital, Department of Radiology, Mikkeli (Finland); Vanninen, Esko J. [Kuopio University Hospital, University of Kuopio, Department of Clinical Physiology and Nuclear Medicine, Kuopio (Finland); Kuikka, Jyrki T. [Kuopio University Hospital, University of Kuopio, Department of Clinical Physiology and Nuclear Medicine, Kuopio (Finland); Niuvanniemi Hospital, Kuopio (Finland); Aronen, Hannu J. [University of Turku, Department of Radiology, Turku (Finland); Vanninen, Ritva L. [Kuopio University Hospital, University of Kuopio, Department of Clinical Radiology, P. O. Box 1777, Kuopio (Finland)

    2009-10-15

    The purposes of the present study were to compare the flow defect volumes on perfusion-weighted magnetic resonance imaging (PWI) and {sup 99m}Tc-labeled ethylcysteinate dimer ({sup 99m}Tc-ECD) single photon emission computed tomography (SPECT) at acute and subacute stages of ischemic stroke and to analyze the relationship between the detected flow defects on the two methods and neurological status and clinical outcomes. Perfusion defects on PWI and SPECT were measured within 48 h and on day 8 of the onset of stroke from 22 patients with their first-ever acute supratentorial ischemic stroke. The primary neurological status was evaluated prior to the imaging. Clinical outcome was assessed at 3 months after the onset of the stroke. The volumes of cerebral blood flow (CBF) defects did not differ between SPECT and PWI within the 48-h examinations. However, the volume of CBF defect was significantly larger on SPECT than on PWI on day 8 (p = 0.03). Within the 48-h examinations, the CBF defect volumes on SPECT and PWI were comparably related to the neurological status. On day 8, the CBF defect volume on SPECT showed higher correlation to the neurological status and more precisely predicted the clinical outcomes at 3 months than PWI. {sup 99m}TC-ECD-SPECT and PWI both have ability to detect cerebral hypoperfusion in patients with ischemic stroke but with some differences. The value of SPECT is more accurate in terms of the delayed outcome, such as prognosis and rehabilitation planning. (orig.)

  6. Scintigraphic and MR perfusion imaging in preoperative evaluation for lung volume reduction surgery. Pilot study results

    International Nuclear Information System (INIS)

    Johkoh, Takeshi; Mueller, N.L.; Kavanagh, P.V

    2000-01-01

    To compare MR perfusion imaging with perfusion scintigraphy in the evaluation of patients with pulmonary emphysema being considered for lung volume reduction surgery. Six patients with pulmonary emphysema and two normal individuals were evaluated by MR perfusion imaging, perfusion scintigraphy, and selective bilateral pulmonary angiography. MR images were obtained with an enhanced fast gradient recalled echo with three-dimensional Fourier transformation technique (efgre 3D) (6.3/1.3; flip angle, 30 deg C; field of view, 45-48 cm; matrix, 256 x 160). The presence or absence of perfusion defects in each segment was evaluated by two independent observers. Using angiography as the gold standard, the sensitivity, specificity, and accuracy of MR perfusion imaging in detecting focal perfusion abnormalities were 90%, 87%, and 89%, respectively, while those of perfusion scintigraphy were 71%, 76%, and 71%, respectively. The diagnostic accuracy of MR perfusion imaging was significantly higher than that of scintigraphy (p<0.001, McNemar test). There was good agreement between two observers for MR perfusion imaging (kappa statistic, 0.66) and only moderate agreement for perfusion scintigraphy (kappa statistic, 0.51). MR perfusion imaging is superior to perfusion scintigraphy in the evaluation of pulmonary parenchymal perfusion in patients with pulmonary emphysema. (author)

  7. The clinical application value of myocardial perfusion imaging in evaluating coronary artery myocardial bridge patients with symptoms

    International Nuclear Information System (INIS)

    Wang Yuetao; Fu Ning; Ding Xuemei; Lu Cunzhi; Zhu Feng; Wang Guanmin; Huang Yijie; Wang Linguang

    2008-01-01

    Objective: Myocardial bridge is a common inborn coronary artery anomaly, myocardial bridge may be associated with myocardial ischemia. Only a few patients with coronary artery myocardial bridge were evaluated with nuclear medicine techniques. The aim of this study was to investigate the role of nuclear cardiology with myocardial perfusion technique in symptomatic myocardial bridge patients. Methods Nineteen myocardial bridge patients with the symptoms of chest pain and chest distress were analyzed retrospectively. 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion images (both exercise and rest) were performed in all. Imaging results were compared with the results of movement electrocardiogram (ECG) and coronary arteriography. The t test or χ 2 test was used to statistically analyze the data with Stata 7.0 software. Results: Of the 19 patients, 18 patients had myocardial bridge locating at the left anterior descending artery, 1 patient at the left anterior descending and left circumflex artery, the mean angiographic systolic occlusion within the myocardial bridge was (65.4 ± 22.1)%. Of these 19 patients, Exercise-rest 99 Tc m -MIBI myocardial perfusion imaging defined positive myocardial ischemia in 10 and negative in 9 patients. Of the 10 patients with 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia, 8 had reversible radioactive defect of partial anterior wall and (or) apex, 1 had reversible defect of post lateral wall and post septal wall, and 1 had reversible defect of inferior wall. The positive predictive value of myocardial perfusion imaging was 52.6% (10/19), which was higher than movement ECG [21.1% (4/19), χ 2 = 4.07, P 99 Tc m -MIBI myocardial periusion imaging defined myocardial ischemia. Six cases with Grade II stenosis, two were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia. Eight cases with Grade III stenosis, seven were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial

  8. Isolated Left Pulmonary Artery Agenesis: A Case Report

    Directory of Open Access Journals (Sweden)

    Tansel Ansal Balcı

    2012-08-01

    Full Text Available Unilateral pulmonary artery agenesis without any cardiovascular malformation is a rare anomaly. We present the imaging findings of a patient who was diagnosed as isolated left pulmonary artery agenesis. A 27-year-old female patient was admitted to our hospital due to dyspnea during exercise for five years. Chest X-ray revealed minimally small left pulmonary hilum and left lung. She was admitted to our clinic with the suspicion of pulmonary artery pathology. Absent perfusion of the left lung with normal ventilation was visualized on scintigraphy. MDCT angiography of pulmonary arteries showed absent left main pulmonary artery with systemic collaterals around left hemithorax. Pulmonary artery agenesis can be asymptomatic and isolated until adulthood. Both scintigraphy and CT angiography images of pulmonary artery agenesis of a patient are rare in the literature. Pulmonary ventilation- perfusion scintigraphy can be used not only for pulmonary embolism but also pathologies involving pulmonary artery and its branches. (MIRT 2012;21:80-83

  9. Homocysteine plasma levels in patients suspected coronary artery disease: Relation to myocardial perfusion image

    International Nuclear Information System (INIS)

    Yao, Z.Y.; He, Q.; Qu, W.

    2002-01-01

    Purpose: Although there is considerable epidemiologic evidence for a relationship between plasma homocysteine (Hcy) levels and coronary artery disease (CAD), not all studies, especially prospective ones have shown such a relationship. The purpose of this study was to investigate a possible association between Hcy plasma levels and myocardial perfusion defect by SPECT in patients suspected CAD. Methods and Materials: A cohort of 238 patients suspected CAD (age: 60.65±10.43, male to female: 172: 66) was examined for Hcy, tetrahydrofolic acid (FH4), vitamine B12 and coronary angiography (CAG). Furthermore, 42 patients also underwent 99m Tc-MIBI myocardial perfusion images (MPI) to assess the myocardial perfusion. Results: There were 69 patients with normal CAG and 63, 60, 42 and 4 patients with 1 vessel, two vessel, 3 vessel and left main coronary stenosis. The plasma Hcy of this group was significantly increased, p 0.05. In patients with >=3 segments myocardial perfusion defect, 10 of them had normal Hcy, and 7 with hyperhomocysteinemia, in patients with 0.05). Conclusion: Our data may indicate that hyperhomocysteinemia represents an independent risk factor in patients with high possibility of CAD rather than a mark of myocardial ischemia or coronary stenosis

  10. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Y.; Hayashida, K.; Uehara, T.; Shimonagata, T.; Nishimura, T.; Osaka Univ., Suita

    1993-01-01

    15 cases of primary pulmonary hypertension were classified into two groups by patterns of perfusion lung scintigraphy. Perfusion scintigrams showed multiple, small, ill-defined defects (mottled + ve) pattern in eight cases, and the remaining seven cases had a normal (mottled - ve) pattern. The mean pulmonary arterial pressure in patients with a mottled pattern (54 ± 10 mmHg) was higher than in those with a normal pattern (42 ± 9 mmHg, p < 0.05). There were no significant differences between the two groups in right ventricular ejection fraction, partial pressures of oxygen in the arterial blood or alveolo-arterial oxygen difference. All the patients with a mottled pattern died within 2 years following the lung scintigraphy. There was a significant difference in the survival curves between the two groups. (author)

  11. The natural history of takotsubo syndrome: a two-year follow-up study with myocardial sympathetic and perfusion G-SPECT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sestini, Stelvio; Mazzeo, Christian; Castagnoli, Antonio [Nuclear Medicine Unit, N.O.P. - S. Stefano, U.S.L. Toscana Centro, Deptartment of Diagnostic Imaging, Prato (Italy); Pestelli, Francesco; Leoncini, Mario; Bellandi, Francesco [Cardiovascular Unit, N.O.P. - S. Stefano, U.S.L, Toscana Centro, Deptartment of Internal Medicine, Prato (Italy); Mansi, Luigi [Nuclear Medicine Unit, University II Naples, Deptartment of Diagnostic Imaging, Naples (Italy); Carrio, Ignasi [Hospital Sant Pau, Nuclear Medicine, Barcelona (Spain)

    2017-02-15

    To investigate changes in sympathetic activity, perfusion, and left ventricular (LV) functionality in takotsubo cardiomyopathy (TTC) patients from onset (T{sub 0}) to post-onset conditions at 1 month (T{sub 1}), 1-2 years (T{sub 2}, T{sub 3}). Twenty-two patients (70 ± 11 years) underwent serial gated single photon emission tomography (G-SPECT) studies with {sup 123}I-mIBG and {sup 99m}Tc-Sestamibi. Statistics were performed using ANOVA/Sheffe post-hoc, correlation test, and receiver operating characteristic (ROC) curve analysis (p < 0.05). Patients presented at T{sub 0} with LV ballooning and reduced early-late mIBG uptake (95%, 100%), left ventricular ejection fraction (LVEF){sub G-SPECT} (86%) and perfusion (77 %). Adrenergic dysfunction was greater in apex, it overlaps with contractile impairment, and both were more severe than perfusion defect. During follow-up, LVEF{sub G-SPECT}, contractility, and perfusion were normal, while 82% and 90% of patients at T{sub 1} and 50% at T{sub 2} and T{sub 3} continued to show a reduced apical early-late mIBG distribution. These patients presented at T{sub 0}-T{sub 1} with greater impairment of adrenergic function, contractility, and perfusion. A relationship was present within innervation and both perfusion and contractile parameters at T{sub 0} and T{sub 1}, and between the extent of adrenergic defect at T{sub 3} and both the defect extent and age at T{sub 0} (cut-off point 42.5%, 72 years). Outcome for TTC is not limited to a reversible contractile and perfusion abnormalities, but it includes residual adrenergic dysfunction, depending on the level of adrenergic impairment and age of patients at onset. The number of patients, as well as degree of perfusion abnormalities were found to be higher than those previously reported possibly depending on the time-interval between hospital admission and perfusion scan. (orig.)

  12. Cerebral perfusion changes in schizophrenia patients evaluated with Tc-99 HMPAO

    International Nuclear Information System (INIS)

    Sehweil, A.; El-Hilu, S.; Jahan, S.; Higazi, E.; Salhat, M.; Al-Mohannadi, S.; Abdel-Dayem, H.M.

    1989-01-01

    Tc-99m HMPAO has been used to image cerebral perfusion changes in 20 chronic schizophrenia patients (19 men and 1 woman), with an average age of 29 years (range, 22-48 years). All were receiving neuroleptic drugs. Twelve had received electroconvulsive therapy. All patients had abnormal studies (except one, which was normal) and poor response to treatment. Ventricular dilation and cerebral atrophy were seen in 11 patients. Seventy-seven focal lesions were detected. Forty-two lesions showed increased HMPAO retention: 26 in the basal ganglia in 14 patients (12, bilateral, two unilateral), 10 along the sylvian fissure in the parietotemporal region, three in the frontal region, and one in each of the temporal, parietal, and occipital regions. Thirty-five focal lesions showed decreased perfusion: 10 parietal, eight frontal, seven temporal, six cerebellar, and four occipital. This study demonstrates the potential value of Tc-99m HMPAO in the study of schizophrenia and other psychiatric disorders

  13. Perfusion study in the pulmonary hilar region by SPECT

    International Nuclear Information System (INIS)

    Satoh, Katashi; Tanabe, Masatada; Kawase, Yoshiro

    1990-01-01

    Alveoli in the hilar region comprise the peripheral area containing daughter branches from subsegmental or one more divisional peripheral bronchi. Pulmonary perfusion in hilar region was examined by SPECT (single photon emission CT) in ten normal volunteers. ROI (region of interest) in the axial images were set in the hilar region, the upper, middle and lower lung fields with 10.8 mm thickness. Counts/one pixel (C/P) were calculated in these ROI. There was a tendency of C/P increase from upper to lower lung field. And there were no significant differences in C/P increase between hilar region and other axial fields. In the chronic obstructive pulmonary diseases, however, ventilation studies in the previous reports using Xe dynamic CT or PET (positron emission tomography) showed differences between outer region and hilar region. This method will be expected to evaluate the pulmonary perfusion not only in the whole lung but in different lung areas, including the hilar region in the chronic obstructive pulmonary diseases. (author)

  14. Unilateral Macular Star in a Case of Hypertension and Retinitis Pigmentosa.

    Science.gov (United States)

    Chawla, Rohan; Tripathy, Koushik; Chaudhary, Sunil; Phuljhele, Swati; Venkatesh, Pradeep

    2017-01-01

    To describe a case of hypertension and retinitis pigmentosa presenting with a unilateral macular star. Case report. A 17-year-old female with chronic kidney disease and hypertension presented with a mild blurring of vision in the left eye. There was a history of night blindness. Both eyes had optic disc pallor, arteriolar attenuation, and peripheral bony spicules suggestive of the triad of retinitis pigmentosa. Macular star was seen in the left eye alone. We ascribe the macular star to hypertension as the patient had only a mild decrease in vision, no relative afferent pupillary defect, and similar visual evoked response amplitude and latency in both eyes. Unilateral macular star may be seen in hypertension and may simulate neuroretinitis in the clinical setting.

  15. Perfusion redistribution after a pulmonary-embolism-like event with contrast enhanced EIT.

    Science.gov (United States)

    Nguyen, D T; Bhaskaran, A; Chik, W; Barry, M A; Pouliopoulos, J; Kosobrodov, R; Jin, C; Oh, T I; Thiagalingam, A; McEwan, A L

    2015-06-01

    Recent studies showed that regional pulmonary perfusion can be reliably estimated using electrical impedance tomography (EIT) with the aid of hypertonic saline based contrast enhancement. Building on these successful studies, we studied contrast EIT for pulmonary perfusion defect caused by an artificially induced pulmonary embolism (PE) in a large ovine model (N = 8, 78 ± 7.8 kg). Furthermore, the efficacy of a less invasive contrast bolus of 0.77 ml kg(-1) of NaCl 3% was compared with a more concentrated bolus of 0.13 ml kg(-1) of NaCl 20%. Prior to the injection of each contrast bolus injection, ventilation was turned off to provide a total of 40 to 45 s of apnoea. Each bolus of impedance contrast was injected through a catheter into the right atrium. Pulmonary embolisation was performed by balloon occlusion of part of the right branch of the pulmonary trunk. Four parameters representing the kinetics of the contrast dilution in the lung were evaluated for statistical differences between baseline and PE, including peak value, maximum uptake, maximum washout and area under the curve of the averaged contrast dilution curve in each lung. Furthermore, the right lung to left lung (R2L) ratio of each the aforementioned parameters were assessed. While all of the R2L ratios yielded significantly different means between baseline and PE, it can be concluded that the R2L ratios of area under the curve and peak value of the averaged contrast dilution curve are the most promising and reliable in assessing PE. It was also found that the efficacy of the two types of impedance contrasts were not significantly different in distinguishing PE from baseline in our model.

  16. A compartment model of alveolar-capillary oxygen diffusion with ventilation-perfusion gradient and dynamics of air transport through the respiratory tract.

    Science.gov (United States)

    Jaworski, Jacek; Redlarski, Grzegorz

    2014-08-01

    This paper presents a model of alveolar-capillary oxygen diffusion with dynamics of air transport through the respiratory tract. For this purpose electrical model representing the respiratory tract mechanics and differential equations representing oxygen membrane diffusion are combined. Relevant thermodynamic relations describing the mass of oxygen transported into the human body are proposed as the connection between these models, as well as the influence of ventilation-perfusion mismatch on the oxygen diffusion. The model is verified based on simulation results of varying exercise intensities and statistical calculations of the results obtained during various clinical trials. The benefit of the approach proposed is its application in simulation-based research aimed to generate quantitative data of normal and pathological conditions. Based on the model presented, taking into account many essential physiological processes and air transport dynamics, comprehensive and combined studies of the respiratory efficiency can be performed. The impact of physical exercise, precise changes in respiratory tract mechanics and alterations in breathing pattern can be analyzed together with the impact of various changes in alveolar-capillary oxygen diffusion. This may be useful in simulation of effects of many severe medical conditions and increased activity level. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Prospective assessment of regional myocardial perfusion before and after coronary revascularization surgery by quantitative thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Gibson, R.S.; Watson, D.D.; Taylor, G.J.; Crosby, I.K.; Wellons, H.L.; Holt, N.D.; Beller, G.A.

    1983-01-01

    Because thallium-201 uptake relates directly to the amount of viable myocardium and nutrient blood flow, the potential for exercise scintigraphy to predict response to coronary revascularization surgery was investigated in 47 consecutive patients. All patients underwent thallium-201 scintigraphy and coronary angiography at a mean (+/- standard deviation) of 4.3 +/- 3.1 weeks before and 7.5 +/- 1.6 weeks after surgery. Thallium uptake and washout were computer-quantified and each of six segments was defined as normal, showing total or partial redistribution or a persistent defect. Persistent defects were further classified according to the percent reduction in regional thallium activity; PD25-50 denoted a 25 to 50% constant reduction in relative thallium activity and PD greater than 50 denoted a greater than 50% reduction. Of 82 segments with total redistribution before surgery, 76 (93%) showed normal thallium uptake and washout postoperatively, versus only 16 (73%) of 22 with partial redistribution (probability [p] . 0.01). Preoperative ventriculography revealed that 95% of the segments with total redistribution had preserved wall motion, versus only 74% of those with partial redistribution (p . 0.01). Of 42 persistent defects thought to represent myocardial scar before surgery, 19 (45%) demonstrated normal perfusion postoperatively. Of the persistent defects that showed improved thallium perfusion postoperatively, 75% had normal or hypokinetic wall motion before surgery, versus only 14% of those without improvement (p less than 0.001). Whereas 57% of the persistent defects that showed a 25 to 50% decrease in myocardial activity demonstrated normal thallium uptake and washout postoperatively, only 21% of the persistent defects with a decrease in myocardial activity greater than 50% demonstrated improved perfusion after surgery (p . 0.02)

  18. Lung perfusion analysis with dual energy CT in patients with suspected pulmonary embolism—Influence of window settings on the diagnosis of underlying pathologies of perfusion defects

    International Nuclear Information System (INIS)

    Bauer, Ralf W.; Kerl, J. Matthias; Weber, Eva; Weisser, Philipp; Korkusuz, Huedayi; Lehnert, Thomas; Jacobi, Volkmar; Vogl, Thomas J.

    2011-01-01

    Purpose: On lung perfusion analysis with dual energy CT (DECT) in patients with suspected pulmonary embolism (PE) commonly three patterns of perfusion defects (PD) are observed: wedge-shaped, circumscribed but not wedge-shaped, and patchy. We investigated the influence of different window settings on the identification of the underlying pathologies for these types of PD. Materials and methods: 3724 segments in 196 consecutive patients who underwent pulmonary DECT angiography for clinically suspected acute PE were analyzed. Iodine distribution in the lung parenchyma was calculated from the dual energy data and displayed as color map in axial, sagittal and coronal view. Afterwards, lung and angiography window were applied separately and assessed for pulmonary embolism and pathologies of the lung parenchyma. Results: 1420 segments in 141 patients showed PD, of which 276 were wedge-shaped, 287 circumscribed and 857 patchy. Circumscribed PD were associated in 99% with interstitial or alveolar fluid collections and in 1% with located bullae. Patchy PD were associated in 65% with emphysematous or fibrotic changes, in 38% with diffuse infiltrations or interstitial fluid collections and in 0.2% with PE. The underlying pathologies for wedge-shaped PD were in 78% PE, in 3% tumors compressing pulmonary arteries, in another 3% located bullae and in further 3% infiltrations. 13% (n = 15) of the segments in this group did not show vascular or parenchymal pathologies, but in 80% (n = 10) of these cases patients had PE in another segment. Totally n = 6 of wedge-shaped PD in 5 patients remained with unclear direct cause. Conclusion: Whereas patchy and circumscribed PD are almost exclusively associated with pathologies of the lung parenchyma, wedge-shaped PD are mostly associated with PE. For a small number of wedge-shaped PD the underlying cause cannot be detected with DECT. Very small peripherally situated micro-emboli may be discussed as a reason. However, prospective trials are

  19. Kinetics of reversible-sequestration of leukocytes by the isolated perfused rat lung

    Energy Technology Data Exchange (ETDEWEB)

    Goliaei, B.

    1980-08-01

    The kinetics and morphology of sequestration and margination of rat leukocytes were studied using an isolated perfused and ventilated rat lung preparation. Whole rat blood, bone marrow suspension, or leukocyte suspensions, were used to perfuse the isolated rat lung. The lung was also perfused with latex particle suspensions and the passage of particles through the lung capillaries was studied. When a leukocyte suspension was perfused through the lung in the single-pass mode, the rate of sequestration decreased as more cells were perfused. In contrast, latex particles of a size comparable to that of leukocytes were totally stopped by the lung. When the leukocyte suspension was recirculated through the lung, cells were rapidly removed from circulation until a steady state was reached, after which no net removal of cells by the lung occurred. These results indicate that leukocytes are reversibly sequestered from circulation. The sequestered cells marginated and attached to the luminal surface of the endothelium of post-capillary venules and veins. A mathematical model was developed based on the assumption that the attachment and detachment of leukocytes to blood vessel walls follows first-order kinetics. The model correctly predicts the following characteristics of the system: (a) the kinetics of the sequestration of leukocytes by the lung; (b) the existence of a steady state when a suspension of leukocytes is recirculated through the lung; and (c) the independence of the fraction of cells remaining in circulation from the starting concentration for all values of starting concentration. (ERB)

  20. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Yoji; Nishimura, Tsunehiko; Kumita, Shin-ichirou; Hayashida, Kohei; Uehara, Toshiisa; Shimonagata, Tsuyoshi; Ohno, Akira

    1991-01-01

    Fifteen cases with primary pulmonary hypertension (PPH) were classified into two groups by using the perfusion lung scan pattern. Eight cases had multiple, small, ill-defined defects (mottled pattern), and remaining seven cases had no mottled pattern. These two groups were compared with mean pulmonary arterial pressure (mean PAP), right ventricular ejection fraction (RVEF), blood gas at room air (PaO 2 ), and alveolar-arterial O 2 difference (A-aDo 2 ). The cases with mottled pattern showed a significant increase in mean PAP. There were no significant differences in RVEF, PaO 2 , and A-aDo 2 , between the groups. The survival rate of the patients with mottled pattern was significantly lower than that without mottled pattern (p<0.05). We concluded that perfusion lung scan is very useful for evaluation of the prognosis in primary pulmonary hypertension. (author)

  1. Feasibility of high-resolution quantitative perfusion analysis in patients with heart failure.

    Science.gov (United States)

    Sammut, Eva; Zarinabad, Niloufar; Wesolowski, Roman; Morton, Geraint; Chen, Zhong; Sohal, Manav; Carr-White, Gerry; Razavi, Reza; Chiribiri, Amedeo

    2015-02-12

    Cardiac magnetic resonance (CMR) is playing an expanding role in the assessment of patients with heart failure (HF). The assessment of myocardial perfusion status in HF can be challenging due to left ventricular (LV) remodelling and wall thinning, coexistent scar and respiratory artefacts. The aim of this study was to assess the feasibility of quantitative CMR myocardial perfusion analysis in patients with HF. A group of 58 patients with heart failure (HF; left ventricular ejection fraction, LVEF ≤ 50%) and 33 patients with normal LVEF (LVEF >50%), referred for suspected coronary artery disease, were studied. All subjects underwent quantitative first-pass stress perfusion imaging using adenosine according to standard acquisition protocols. The feasibility of quantitative perfusion analysis was then assessed using high-resolution, 3 T kt perfusion and voxel-wise Fermi deconvolution. 30/58 (52%) subjects in the HF group had underlying ischaemic aetiology. Perfusion abnormalities were seen amongst patients with ischaemic HF and patients with normal LV function. No regional perfusion defect was observed in the non-ischaemic HF group. Good agreement was found between visual and quantitative analysis across all groups. Absolute stress perfusion rate, myocardial perfusion reserve (MPR) and endocardial-epicardial MPR ratio identified areas with abnormal perfusion in the ischaemic HF group (p = 0.02; p = 0.04; p = 0.02, respectively). In the Normal LV group, MPR and endocardial-epicardial MPR ratio were able to distinguish between normal and abnormal segments (p = 0.04; p = 0.02 respectively). No significant differences of absolute stress perfusion rate or MPR were observed comparing visually normal segments amongst groups. Our results demonstrate the feasibility of high-resolution voxel-wise perfusion assessment in patients with HF.

  2. Fractal ventilation enhances respiratory sinus arrhythmia

    Directory of Open Access Journals (Sweden)

    Girling Linda G

    2005-05-01

    Full Text Available Abstract Background Programming a mechanical ventilator with a biologically variable or fractal breathing pattern (an example of 1/f noise improves gas exchange and respiratory mechanics. Here we show that fractal ventilation increases respiratory sinus arrhythmia (RSA – a mechanism known to improve ventilation/perfusion matching. Methods Pigs were anaesthetised with propofol/ketamine, paralysed with doxacurium, and ventilated in either control mode (CV or in fractal mode (FV at baseline and then following infusion of oleic acid to result in lung injury. Results Mean RSA and mean positive RSA were nearly double with FV, both at baseline and following oleic acid. At baseline, mean RSA = 18.6 msec with CV and 36.8 msec with FV (n = 10; p = 0.043; post oleic acid, mean RSA = 11.1 msec with CV and 21.8 msec with FV (n = 9, p = 0.028; at baseline, mean positive RSA = 20.8 msec with CV and 38.1 msec with FV (p = 0.047; post oleic acid, mean positive RSA = 13.2 msec with CV and 24.4 msec with FV (p = 0.026. Heart rate variability was also greater with FV. At baseline the coefficient of variation for heart rate was 2.2% during CV and 4.0% during FV. Following oleic acid the variation was 2.1 vs. 5.6% respectively. Conclusion These findings suggest FV enhances physiological entrainment between respiratory, brain stem and cardiac nonlinear oscillators, further supporting the concept that RSA itself reflects cardiorespiratory interaction. In addition, these results provide another mechanism whereby FV may be superior to conventional CV.

  3. Emergency perfusion lung scan of pulmonary embolism

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Kabuto, Hiroko; Rikimaru, Shigeho

    1984-01-01

    Pulmonary embolism (PE) has been reported to be quite rare in Japan, and there have been few clinical studies on the nuclear diagnosis of PE with the exception of several case reports. However, we have experienced 12 acute PE, and 2 chronic PE in 5 years 2 months. In 33 emergency cases who were highly suspected to have PE, we could diagnose 12 cases of PE, and 19 cases of non-PE. However, the remaining 2 cases were equivocal because of underlying chronic lung disease. Using Kr-81m ventilation lung scan, V/Q mismatch was found in all of 10 cases. Usefulness of emergency perfusion lung scan in Japan should be stressed. (author)

  4. Thallium-201 myocardial perfusion imaging during transient coronary occlusion at the time of PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Inagaki, Suetsugu

    1989-01-01

    To evaluate myocardial perfusion during transient coronary arterial occlusion, thallium-201 was administered intravenously during percutaneous transluminall coronary angioplasty (PTCA) in 12 patients with effort angina, and the resulting perfusion images were compared with those of exercise stress obtained before PTCA. Thallium-201 was injected at the last inflation of an angioplastic baloon and occlusion was maintained for 60 to 90 sec. Three projections of planar images were obtained immediately after PTCA, using a portable gamma camera in an angiography room. These perfusion images obtained during PTCA and exercise were visually interpreted and compared. Myocardial perfusion defects due to the responsible vessel occlusion were observed at early imaging after PTCA, and were fully redistributed three hrs post injection. In 10 patients without angiographically imaged collateral vessels, there were no significatn differences in perfusion between images during PTCA and during exercise. Two patients whose collaterals were observed during coronary angiography before PTCA had higher perfusion scores during PTCA than during exercise. We concluded that intravenous injection of thallium-201 during PTCA is a useful means for assessing alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedures, and that it provides more precise information about the jeopardized myocardium, perfused by antegrade blood flow. (author)

  5. Channelized relevance vector machine as a numerical observer for cardiac perfusion defect detection task

    Science.gov (United States)

    Kalayeh, Mahdi M.; Marin, Thibault; Pretorius, P. Hendrik; Wernick, Miles N.; Yang, Yongyi; Brankov, Jovan G.

    2011-03-01

    In this paper, we present a numerical observer for image quality assessment, aiming to predict human observer accuracy in a cardiac perfusion defect detection task for single-photon emission computed tomography (SPECT). In medical imaging, image quality should be assessed by evaluating the human observer accuracy for a specific diagnostic task. This approach is known as task-based assessment. Such evaluations are important for optimizing and testing imaging devices and algorithms. Unfortunately, human observer studies with expert readers are costly and time-demanding. To address this problem, numerical observers have been developed as a surrogate for human readers to predict human diagnostic performance. The channelized Hotelling observer (CHO) with internal noise model has been found to predict human performance well in some situations, but does not always generalize well to unseen data. We have argued in the past that finding a model to predict human observers could be viewed as a machine learning problem. Following this approach, in this paper we propose a channelized relevance vector machine (CRVM) to predict human diagnostic scores in a detection task. We have previously used channelized support vector machines (CSVM) to predict human scores and have shown that this approach offers better and more robust predictions than the classical CHO method. The comparison of the proposed CRVM with our previously introduced CSVM method suggests that CRVM can achieve similar generalization accuracy, while dramatically reducing model complexity and computation time.

  6. Time-course of myocardial perfusion and fatty acid metabolism after coronary reperfusion

    International Nuclear Information System (INIS)

    Sochor, H.; Pachinger, O.; Ogris, E.; Probst, P.; Kaindl, F.

    1985-01-01

    To investigate the relationship and time-course of myocardial perfusion and behaviour of fatty acid uptake and clearance following reperfusion, the authors studied 19 patients after successful intracoronary thrombolysis with Tl-201 and I-123 hepta-decanoic acid (HDA) and planar imaging. Pts were studied acute (A: 48 hours), early (E:6-8 days) and late (L:6-12 months). %-defect size and relative tracer uptake were determined for both markers as well as t1/2 of the early clearance phase for HDA. Late Tl was done as stress test study after dipyridamole infusion. As in a previous report acute HDA uptake-defects were larger than Tl (38 +- 10% vs 24 +- 9%, p<0.05) suggesting a larger area of metabolic impairment than outlined by perfusion. HDA and Tl uptake at A correlated significantly (p<0.01, r=0.86) but HDA uptake was 19% lower than Tl and not different at E and L. Tl stress studies exhibited in 74% reversible ischemia in the area of ''metabolic recovery''. The authors conclude that early after reperfusion uptake of HDA is frequently impaired despite improved perfusion suggesting metabolic derangement showing a slow recovery over time. A multiple tracer approach including metabolic markers may improve the characterization of reperfused myocardium

  7. Creation of a Bioengineered Skin Flap Scaffold with a Perfusable Vascular Pedicle.

    Science.gov (United States)

    Jank, Bernhard J; Goverman, Jeremy; Guyette, Jacques P; Charest, Jon M; Randolph, Mark; Gaudette, Glenn R; Gershlak, Joshua R; Purschke, Martin; Javorsky, Emilia; Nazarian, Rosalynn M; Leonard, David A; Cetrulo, Curtis L; Austen, William G; Ott, Harald C

    2017-07-01

    Full-thickness skin loss is a challenging problem due to limited reconstructive options, demanding 75 million surgical procedures annually in the United States. Autologous skin grafting is the gold standard treatment, but results in donor-site morbidity and poor aesthetics. Numerous skin substitutes are available on the market to date, however, none truly functions as full-thickness skin due to lack of a vascular network. The creation of an autologous full-thickness skin analogue with a vascular pedicle would result in a paradigm shift in the management of wounds and in reconstruction of full-thickness skin defects. To create a clinically relevant foundation, we generated an acellular skin flap scaffold (SFS) with a perfusable vascular pedicle of clinically relevant size by perfusion decellularization of porcine fasciocutaneous flaps. We then analyzed the yielded SFS for mechanical properties, biocompatibility, and regenerative potential in vitro and in vivo. Furthermore, we assessed the immunological response using an in vivo model. Finally, we recellularized the vascular compartment of an SFS and reconnected it to a recipient's blood supply to test for perfusability. Perfusion decellularization removed all cellular components with preservation of native extracellular matrix composition and architecture. Biaxial testing revealed preserved mechanical properties. Immunologic response and biocompatibility assessed via implantation and compared with native xenogenic skin and commercially available dermal substitutes revealed rapid neovascularization and complete tissue integration. Composition of infiltrating immune cells showed no evidence of allorejection and resembled the inflammatory phase of wound healing. Implantation into full-thickness skin defects demonstrated good tissue integration and skin regeneration without cicatrization. We have developed a protocol for the generation of an SFS of clinically relevant size, containing a vascular pedicle, which can be

  8. Independent lung ventilation in a newborn with asymmetric acute lung injury due to respiratory syncytial virus: a case report

    Directory of Open Access Journals (Sweden)

    Di Nardo Matteo

    2008-06-01

    Full Text Available Abstract Introduction Independent lung ventilation is a form of protective ventilation strategy used in adult asymmetric acute lung injury, where the application of conventional mechanical ventilation can produce ventilator-induced lung injury and ventilation-perfusion mismatch. Only a few experiences have been published on the use of independent lung ventilation in newborn patients. Case presentation We present a case of independent lung ventilation in a 16-day-old infant of 3.5 kg body weight who had an asymmetric lung injury due to respiratory syncytial virus bronchiolitis. We used independent lung ventilation applying conventional protective pressure controlled ventilation to the less-compromised lung, with a respiratory frequency proportional to the age of the patient, and a pressure controlled high-frequency ventilation to the atelectatic lung. This was done because a single tube conventional ventilation protective strategy would have exposed the less-compromised lung to a high mean airways pressure. The target of independent lung ventilation is to provide adequate gas exchange at a safe mean airways pressure level and to expand the atelectatic lung. Independent lung ventilation was accomplished for 24 hours. Daily chest radiograph and gas exchange were used to evaluate the efficacy of independent lung ventilation. Extubation was performed after 48 hours of conventional single-tube mechanical ventilation following independent lung ventilation. Conclusion This case report demonstrates the feasibility of independent lung ventilation with two separate tubes in neonates as a treatment of an asymmetric acute lung injury.

  9. Lung perfusion characteristics in pulmonary arterial hypertension (PAH) and peripheral forms of chronic thromboembolic pulmonary hypertension (pCTEPH): Dual-energy CT experience in 31 patients

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, Jessica; Khung, Suonita; Remy, Jacques; Remy-Jardin, Martine [Hospital Calmette (EA 2694), Department of Thoracic Imaging, Lille (France); Duhamel, Alain [University Lille, CHU Lille, Department of Biostatistics, Lille (France); Hossein-Foucher, Claude; Bellevre, Dimitri [University Lille, CHU Lille, Department of Nuclear Medicine, Hospital Salengro, Lille (France); Lamblin, Nicolas [University Lille, CHU Lille, Department of Cardiology, Cardiology Hospital, Lille (France)

    2017-04-15

    To compare lung perfusion in PAH and pCTEPH on dual-energy CT (DECT) examinations. Thirty-one patients with PAH (group 1; n = 19) and pCTEPH (group 2; n = 12) underwent a dual-energy chest CTA with reconstruction of diagnostic and perfusion images. Perfusion alterations were analysed at a segmental level. V/Q scintigraphy was available in 22 patients (group 1: 13/19; group 2: 9/12). CT perfusion was abnormal in 52.6 % of group 1 patients and in 100 % of group 2 patients (p = 0.0051). The patterns of perfusion alteration significantly differed between the two groups (p < 0.0001): (1) in group 1, 96.6 % of segments with abnormal perfusion showed patchy defects; (2) in group 2, the most frequent abnormalities consisted of patchy (58.5 %) and PE-type (37.5 %) defects. Paired comparison of CT perfusion and scintigraphy showed concordant findings in 76.9 % of group 1 (10/13) and 100 % of group 2 (9/9) patients, with a predominant or an exclusive patchy pattern in group 1 and a mixed pattern of abnormalities in group 2. Lung perfusion alterations at DECT are less frequent and more homogeneous in PAH than in pCTEPH, with a high level of concordant findings with V/Q scintigraphy. (orig.)

  10. Pattern-reversal electroretinograms in unilateral glaucoma.

    Science.gov (United States)

    Wanger, P; Persson, H E

    1983-06-01

    Pattern-reversal and flash electroretinograms (ERG) and oscillatory potentials (OP) were recorded from 11 patients with unilateral glaucoma. All glaucomatous eyes had reduced amplitudes both compared to the opposite eye in the same patient and to reference values. In 10 of the 11 cases this reduction was below the level of normal variation. The difference in pattern-reversal ERG amplitude means from glaucomatous and opposite eyes was statistically significant. No differences were observed in flash ERGs or OPs. The histopathologic correlate to the visual field defects in glaucoma is retinal ganglion cell degeneration. The present electrophysiologic findings support the view, based on results from animal experiments, that the pattern-reversal ERG reflects ganglion cell activity.

  11. The clinical application of SPECT myocardial perfusion imaging with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Dong Weiyu

    1992-01-01

    This paper reported 182 SPECT myocardial perfusion images with China made 99m Tc-MIBI and were compared with ECG and UCG. The sensitivity of SPECT in ischemic were 91.2% and was higher than ECG (74.9%)and UCG (61.8%) (P < 0.01). And its specificity, accuracy and positive predictive rate were 78.3%, 90% and 97% respectively. Besides 9 cases have reverse distribution after exercise and rest images. In some ICD patients had shown their SPECT images, the perfusion defects in exercise as well as in rest image

  12. The place of krypton-81m ventilation in the scintigraphic investigation of the lung

    International Nuclear Information System (INIS)

    Hoefnagel, C.A.; Marcuse, H.R.

    1983-01-01

    Fairly recently krypton-81m gas became available for diagnostic purposes. Its advantages and ways to use are surveyed especially for the diagnosis of lung emboli and lung diseases. The combination of perfusion and ventilation scintigrams is the best for specifying the diagnosis. Krypton-81m gas improves the specificity and sensitivity of the examination which is non-invasive and carries no burden for the patient. (Auth.)

  13. N-acetylcysteine ameliorates contrast‑induced kidney injury in rats with unilateral hydronephrosis.

    Science.gov (United States)

    Xia, Qiang; Liu, Chunxiao; Zheng, Xia

    2018-02-01

    The aim of the present study was to investigate the protective effects of N‑acetylcysteine (NAC) on contrast‑induced acute kidney injury in rats with unilateral hyronephrosis. Eighty‑two male Sprague Dawley rats were randomized to undergo sham operation (n=14) or unilateral ureteral obstruction (UUO) (n=68). After 3 weeks, the UUO animals were randomized to three groups: NAC gastric perfusion, UUO+iohexol+NAC (n=24); normal saline perfusion, UUO+iohexol (n=24); and controls, UUO (n=20). After 3 days, UUO+iohexol+NAC and UUO+iohexol rats were injected with iohexol. One day after contrast, half of the rats were sacrificed to assess the pathological changes to the kidneys, serum creatinine, serum neutrophil gelatinase‑associated lipocalin (NGAL), renal cell apoptosis rate and expression of apoptosis regulators Bcl‑2/Bax. The remaining rats underwent obstruction relief and were analyzed 3 weeks later. Compared with the controls, serum NGAL levels were high in UUO+iohexol rats 1 day following injection and 3 weeks after obstruction relief, but UUO+iohexol+NAC rats exhibited lower serum NGAL levels compared with UUO+iohexol rats (all Pmodeling, UUO+iohexol rats exhibited a significantly higher apoptosis rate of renal tubular cells, higher expression of Bax mRNA, and lower ratio of Bcl‑2/Bax (all Prelief, UUO+iohexol+NAC rats exhibited a lower apoptosis rate, lower Bax mRNA expression, higher expression of Bcl‑2 mRNA and higher ratio of Bcl‑2/Bax (all P<0.05) compared with day 1 following drug administration. The prophylactic use of NAC reduced the apoptotic rate of renal tubular cells following contrast exposition, which was accompanied by changes in the expression of Bcl‑2/Bax mRNA.

  14. Prognostic value of abnormal exercise myocardial perfusion imaging and its types in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Zhu Mei; Pan Zhongyun; Lin JInghui; Zhang Chunli; Nie Tao; Wang Yanfu

    1998-01-01

    Purpose: To evaluate the prognostic value of abnormal exercise myocardial perfusion imaging and its types in patients with coronary artery disease (CAD). Methods: 69 patients with CAD underwent exercise myocardial perfusing imaging and exercise ECG test. The images of all of them were abnormal. 45 patients were angiographically proved CAD. Follow-up period ranged from 6∼110 months and even longer than 12 months for patients with no cardiac events (CE). Results: CE occurred in 15 patients during the follow-up period. The CE incidence was 8.7% per year. Cox regression analysis revealed that there was a good correlation between the number of myocardial segments with reversible defects and future CE. Comparing the results of 13 patients with small extent irreversible defects with the data obtained from normal subjects reported previously, there was no significant difference between two no-CE rates (x 2 = 0.09, P>0.05). Conclusions: Normal myocardial images and irreversible defects involving rather small areas predicted an excellent prognosis. The better predictor of future CE is the quantity of myocardial segments with reversible defect

  15. Diagnostic value of transmural perfusion ratio derived from dynamic CT-based myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Coenen, Adriaan; Lubbers, Marisa M.; Dedic, Admir; Chelu, Raluca G.; Geuns, Robert-Jan M. van; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Cardiology, Rotterdam (Netherlands); Kurata, Akira; Kono, Atsushi; Dijkshoorn, Marcel L. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Rossi, Alexia [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Barts Health NHS Trust, NIHR Cardiovascular Biomedical Research Unit at Barts, William Harvey Research Institute, Barts and The London School of Medicine and Dentistry, Queen Mary University of London and Department of Cardiology, London (United Kingdom)

    2017-06-15

    To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). Subjects with suspected or known coronary artery disease were prospectively included and underwent a CT-MPI examination. From the CT-MPI time-point data absolute myocardial blood flow (MBF) values were temporally resolved using a hybrid deconvolution model. An absolute MBF value was measured in the suspected perfusion defect. TPR was defined as the ratio between the subendocardial and subepicardial MBF. TPR and MBF results were compared with invasive FFR using a threshold of 0.80. Forty-three patients and 94 territories were analysed. The area under the receiver operator curve was larger for MBF (0.78) compared with TPR (0.65, P = 0.026). No significant differences were found in diagnostic classification between MBF and TPR with a territory-based accuracy of 77 % (67-86 %) for MBF compared with 70 % (60-81 %) for TPR. Combined MBF and TPR classification did not improve the diagnostic classification. Dynamic CT-MPI-based transmural perfusion ratio predicts haemodynamically significant coronary artery disease. However, diagnostic performance of dynamic CT-MPI-derived TPR is inferior to quantified MBF and has limited incremental value. (orig.)

  16. When is reacquisition necessary due to high extra-cardiac uptake in myocardial perfusion scintigraphy?

    DEFF Research Database (Denmark)

    Johansen, Allan; Lomsky, Milan; Gerke, Oke

    2013-01-01

    Technetium-labeled agents, which are most often used for assessing myocardial perfusion in myocardial perfusion scintigraphy (MPS), are cleared by the liver and excreted by the biliary system. Spillover from extra-cardiac activity into the myocardium, especially the inferior wall, might conceal d...... defects and lower the diagnostic accuracy of the study. The objective was to determine rules of thumb for when reacquisition is useful due to high extra-cardiac uptake, i.e., when interpretation of the studies was affected by poor image quality....

  17. Correlation of the myocardial perfusion corrected by attenuation with the coronariography. Preliminary results

    International Nuclear Information System (INIS)

    Garcia C, S.E.; Garcia O, R.

    2005-01-01

    The attenuation that suffers the radiation in the soft tissues of the hinders the appropriate interpretation of the myocardial perfusion studies, for what have been implemented attenuation correction systems to reduce the attenuation for soft tissues and to provide myocardial perfusion images more accurate in the diagnosis of coronary illness. The objective was to evaluate the utility of an attenuation correction system (with source of Gadolinium 153) to minimize the devices that look like true defects of myocardial perfusion, caused by soft tissues (mammary tissue, thoracic wall, abdomen, left hemi diaphragm), and to compare those interpretations of the studies with the interpretations of the corresponding coronariographies. The method consists of 95 electronic files which were revised with the concept of heart catheterization, being identified 20 patients from the masculine sex to those that underwent coronariography among May 1999 and December 2002, and that they had study of myocardial perfusion in a maximum period of 3 months foresaw to the invasive procedure. (Author)

  18. Reevaluation of lung perfusion scintigrams with 99mTc-macroaggregated albumin (Tc-MAA) as a tool of diagnostic procedures of chronic pulmonary emphysema

    International Nuclear Information System (INIS)

    Kitahara, Yoshinari; Maruyama, Masao; Takamoto, Masahiro; Tanaka, Yasushi; Harada, Susumu; Harada, Yasuko; Ishibashi, Tsuneo; Shinoda, Atsushi

    1991-01-01

    We performed scintiscanning with Tc-MAA lung perfusion in thirty cases of chronic pulmonary emphysema (CPE) and thirty cases of bronchial asthma. In the former group, all of the cases showed the definite emphysematous changes on computed tomography (CT). It seemed that the whole impression to scintigram could diagnose CPE almost correctly. As the most important abnormality in scintigrams of CPE was their filling defects, we examined the characteristics of the defect-lesions. The results were as follows: firstly, the main lesions extended to the lobar to half-lobar size; secondly, defects were multiple in general; and thirdly, the distribution of defects was diffuse. Whereas the lesion in the scintigram is nonspecific for diagnosis of CPE in contrast to CT, we conclude that perfusion scintigram is valuable to evaluate the severity of CPE. (author)

  19. High frequency jet ventilation and intermittent positive pressure ventilation. Effect of cerebral blood flow in patients after open heart surgery

    International Nuclear Information System (INIS)

    Pittet, J.F.; Forster, A.; Suter, P.M.

    1990-01-01

    Attenuation of ventilator-synchronous pressure fluctuations of intracranial pressure has been demonstrated during high frequency ventilation in animal and human studies, but the consequences of this effect on cerebral blood flow have not been investigated in man. We compared the effects of high frequency jet ventilation and intermittent positive pressure ventilation on CBF in 24 patients investigated three hours after completion of open-heart surgery. The patients were investigated during three consecutive periods with standard sedation (morphine, pancuronium): a. IPPV; b. HFJV; c. IPPV. Partial pressure of arterial CO 2 (PaCO 2 : 4.5-5.5 kPa) and rectal temperature (35.5 to 37.5 degree C) were maintained constant during the study. The CBF was measured by intravenous 133 Xe washout technique. The following variables were derived from the cerebral clearance of 133 Xe: the rapid compartment flow, the initial slope index, ie, a combination of the rapid and the slow compartment flows, and the ratio of fast compartment flow over total CBF (FF). Compared to IPPV, HFJV applied to result in the same mean airway pressure did not produce any change in pulmonary gas exchange, mean systemic arterial pressure, and cardiac index. Similarly, CBF was not significantly altered by HFJV. However, important variations of CBF values were observed in three patients, although the classic main determinants of CBF (PaCO 2 , cerebral perfusion pressure, Paw, temperature) remained unchanged. Our results suggest that in patients with normal systemic hemodynamics, the effects of HFJV and IPPV on CBF are comparable at identical levels of mean airway pressure

  20. Perfusion-induced changes in cardiac contractility depend on capillary perfusion.

    Science.gov (United States)

    Dijkman, M A; Heslinga, J W; Sipkema, P; Westerhof, N

    1998-02-01

    The perfusion-induced increase in cardiac contractility (Gregg phenomenon) is especially found in heart preparations that lack adequate coronary autoregulation and thus protection of changes in capillary pressure. We determined in the isolated perfused papillary muscle of the rat whether cardiac muscle contractility is related to capillary perfusion. Oxygen availability of this muscle is independent of internal perfusion, and perfusion may be varied or even stopped without loss of function. Muscles contracted isometrically at 27 degrees C (n = 7). During the control state stepwise increases in perfusion pressure resulted in all muscles in a significant increase in active tension. Muscle diameter always increased with increased perfusion pressure, but muscle segment length was unaffected. Capillary perfusion was then obstructed by plastic microspheres (15 microns). Flow, at a perfusion pressure of 66.6 +/- 26.2 cmH2O, reduced from 17.6 +/- 5.4 microliters/min in the control state to 3.2 +/- 1.3 microliters/min after microspheres. Active tension developed by the muscle in the unperfused condition before microspheres and after microspheres did not differ significantly (-12.8 +/- 29.4% change). After microspheres similar perfusion pressure steps as in control never resulted in an increase in active tension. Even at the two highest perfusion pressures (89.1 +/- 28.4 and 106.5 +/- 31.7 cmH2O) that were applied a significant decrease in active tension was found. We conclude that the Gregg phenomenon is related to capillary perfusion.

  1. Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Toke Rammer; Svendsen, Sv Aa Højgaard

    1999-01-01

    The note concerns ventilation in residential buildings. Describes components in ventilation systems, electric energy consumption and different ventilation systems with heat exchanger.......The note concerns ventilation in residential buildings. Describes components in ventilation systems, electric energy consumption and different ventilation systems with heat exchanger....

  2. : ventilators for noninvasive ventilation

    OpenAIRE

    Fauroux , Brigitte; Leroux , Karl; Desmarais , Gilbert; Isabey , Daniel; Clément , Annick; Lofaso , Frédéric; Louis , Bruno

    2008-01-01

    International audience; The aim of the present study was to evaluate the performance characteristics of all the ventilators proposed for home noninvasive positive-pressure ventilation in children in France. The ventilators (one volume-targeted, 12 pressure-targeted and four dual) were evaluated on a bench which simulated six different paediatric ventilatory patterns. For each ventilator, the quality of the inspiratory and expiratory trigger and the ability to reach and maintain the preset pre...

  3. Hepatic perfusion during hepatic artery infusion chemotherapy: Evaluation with perfusion CT and perfusion scintigraphy

    International Nuclear Information System (INIS)

    Miller, D.L.; Carrasquillo, J.A.; Lutz, R.J.; Chang, A.E.

    1989-01-01

    The standard method for the evaluation of hepatic perfusion during hepatic artery infusion (HAI) chemotherapy is planar hepatic artery perfusion scintigraphy (HAPS). Planar HAPS was performed with 2 mCi of [99mTc] macroaggregated albumin infused at 1 ml/min and compared with single photon emission CT (SPECT) HAPS and with a new study, CT performed during the slow injection of contrast material through the HAI catheter (HAI-CT). Thirteen patients underwent 16 HAI-CT studies, 14 planar HAPS studies, and 9 SPECT HAPS studies. In 13 of 14 studies (93%) HAI-CT and planar HAPS were in complete agreement as to the perfusion pattern of intrahepatic metastases and normal liver. In nine studies where all modalities were performed, the findings identified by HAI-CT and planar HAPS agreed in all cases, whereas the results of two SPECT scans disagreed with the other studies. With respect to perfusion of individual metastases, 14 of 14 HAI-CT studies, 12 of 13 planar HAPS studies, and 9 of 9 SPECT HAPS studies correctly demonstrated the perfusion status of individual lesions as indicated by the pattern of changes in tumor size determined on CT obtained before and after the perfusion studies. Hepatic artery infusion CT was superior for delineation of individual metastases, particularly small lesions, and for the evaluation of nonperfused portions of the liver. Planar HAPS detected extrahepatic perfusion in four patients, and this was not detected by HAI-CT. We conclude that HAI-CT and scintigraphy are complementary techniques. Hepatic artery infusion CT has advantages for the evaluation of intrahepatic perfusion, and planar HAPS is superior to HAI-CT for the detection of extrahepatic perfusion

  4. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    International Nuclear Information System (INIS)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K.; Nandurkar, Dee; Troupis, John M.

    2013-01-01

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 ± 7.4 mSv compared with 13.2 ± 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  5. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, Monash Heart, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Nandurkar, Dee; Troupis, John M. [MMC, Southern Health, Department of Diagnostic Imaging, Melbourne (Australia)

    2013-07-15

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 {+-} 7.4 mSv compared with 13.2 {+-} 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  6. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T

    Energy Technology Data Exchange (ETDEWEB)

    Kjoerstad, Aasmund; Corteville, Dominique M.R.; Zoellner, Frank G.; Schad, Lothar R. [Heidelberg Univ., Medical Faculty Mannheim (Germany). Computer Assisted Clinical Medicine; Henzler, Thomas [Heidelberg Univ., Medical Faculty Mannheim (Germany). Inst. of Clinical Radiology and Nuclear Medicine; Schmid-Bindert, Gerald [Heidelberg Univ., Medical Faculty Mannheim (Germany). Interdisciplinary Thoracic Oncology

    2015-07-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15±0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93±0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61±1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Conclusion Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue.

  7. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2015-12-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15 ± 0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93 ± 0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61 ± 1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue. Copyright © 2015. Published by Elsevier GmbH.

  8. Reduced myocardial perfusion reserve in myocardium having coronary artery aneurysm of Kawasaki disease

    International Nuclear Information System (INIS)

    Yoon, S. N.; Lee, D. S.; Choi, J. Y.; Kil, H. R.; Jeong, Z. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Kawasaki disease is a systemic vasculitis involving the coronary arteries at early childhood and cause coronary artery aneurysms and thrombotic occlusions. These coronary artery aneurysms were usually transformed later into stenotic or obstructive lesions, however, the majority of these aneurysms, even the giant ones, are known to be associated with normal epicardial coronary flow. Flow reserve is difficult to assess in aneurysmal arteries with echo or angiography. We performed this study to question if there are abnormalities in flow reserve in myocardial tissue with normal epicardial arterial flow on angiography in patients with Kawasaki disease, dipyridamole stress and rest Tc-99m-sestamibi SPECT were performed in 37 patients (28 boys, 9 girls, mean age 6.6 years). We compared SPECT findings with coronary angiography (CAG) findings in 21 patients who did both studies after finding abnormality on echocardiaography. On CAG, aneurysms were found in 26 arteries of 16 patients, i.e., 10 left main arteries, 6 left anterior descending arteries (LAD), 2 left circumflex arteries (LCX), and 8 right coronary arteries (RCA). Localized and segmental stenotic lesions were found in 11 arteries in 9 patients (LAD: 4, LCX: 1, RCA: 6). Eight of the 10 patients with aneurysms had no obvious stenosis. On stress-rest SPECT, 16(43%) out of 37 patients showed normal perfusion and the other 21(57%) showed reversible or persistent decrease. Among 11 stenotic artery territories, 3(27%) showed persistent and/or reversible perfusion defects. The other 8 were normal. Among 26 aneurysmal artery territories, 12 artery territories showe perfusion decrease. Three of the 5 patients with normal CAG showed persistent and/or transient perfusion defects. Among 14 artery territories with perfusion decrease in the 16 patients, 3(21%) could be localized to vascular territory having stenosis of supplying coronary arteries, 12(86%) were related to the coronary artery aneurysms. Two were not related to

  9. Effects of ventilation strategy on distribution of lung inflammatory cell activity

    Science.gov (United States)

    2013-01-01

    Introduction Leukocyte infiltration is central to the development of acute lung injury, but it is not known how mechanical ventilation strategy alters the distribution or activation of inflammatory cells. We explored how protective (vs. injurious) ventilation alters the magnitude and distribution of lung leukocyte activation following systemic endotoxin administration. Methods Anesthetized sheep received intravenous endotoxin (10 ng/kg/min) followed by 2 h of either injurious or protective mechanical ventilation (n = 6 per group). We used positron emission tomography to obtain images of regional perfusion and shunting with infused 13N[nitrogen]-saline and images of neutrophilic inflammation with 18F-fluorodeoxyglucose (18F-FDG). The Sokoloff model was used to quantify 18F-FDG uptake (Ki), as well as its components: the phosphorylation rate (k3, a surrogate of hexokinase activity) and the distribution volume of 18F-FDG (Fe) as a fraction of lung volume (Ki = Fe × k3). Regional gas fractions (fgas) were assessed by examining transmission scans. Results Before endotoxin administration, protective (vs. injurious) ventilation was associated with a higher ratio of partial pressure of oxygen in arterial blood to fraction of inspired oxygen (PaO2/FiO2) (351 ± 117 vs. 255 ± 74 mmHg; P ventilation, which also increased the shunt fraction in dependent lung. Protective ventilation resulted in less nonaerated lung (20-fold; P protective (vs. injurious) ventilation, especially in dependent lung regions (0.0075 ± 0.0043/min vs. 0.0157 ± 0.0072/min; P ventilation and accounted for most of the between-group difference in Ki. Dependent regions of the protective ventilation group exhibited lower k3 values per neutrophil than those in the injurious ventilation group (P = 0.01). In contrast, Fe was not affected by ventilation strategy (P = 0.52). Lung neutrophil counts were not different between groups, even when regional inflation was accounted for. Conclusions During systemic

  10. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  11. Lung perfusion and emphysema distribution affect the outcome of endobronchial valve therapy

    Directory of Open Access Journals (Sweden)

    Thomsen C

    2016-06-01

    Full Text Available Christian Thomsen,1 Dorothea Theilig,2 Dominik Herzog,1 Alexander Poellinger,2 Felix Doellinger,2 Nils Schreiter,3 Vera Schreiter,2 Dirk Schürmann,1 Bettina Temmesfeld-Wollbrueck,1 Stefan Hippenstiel,1 Norbert Suttorp,1 Ralf-Harto Hubner1 1Department of Internal Medicine/Infectious Diseases and Respiratory Medicine, 2Institute of Radiology, 3Institute of Nuclear Medicine, Charité – Universitätsmedizin Berlin, Berlin, Germany Abstract: The exclusion of collateral ventilation (CV and other factors affect the clinical success of endoscopic lung volume reduction (ELVR. However, despite its benefits, the outcome of ELVR remains difficult to predict. We investigated whether clinical success could be predicted by emphysema distribution assessed by computed tomography scan and baseline perfusion assessed by perfusion scintigraphy. Data from 57 patients with no CV in the target lobe (TL were retrospectively analyzed after ELVR with valves. Pulmonary function tests (PFT, St George’s Respiratory Questionnaire (SGRQ, and 6-minute walk tests (6MWT were performed on patients at baseline. The sample was grouped into high and low levels at the median of TL perfusion, ipsilateral nontarget lobe (INL perfusion, and heterogeneity index (HI. These groups were analyzed for association with changes in outcome parameters from baseline to 3 months follow-up. Compared to baseline, patients showed significant improvements in PFT, SGRQ, and 6MWT (all P≤0.001. TL perfusion was not associated with changes in the outcome. High INL perfusion was significantly associated with increases in 6MWT (P=0.014, and high HI was associated with increases in forced expiratory volume in 1 second (FEV1, (P=0.012. Likewise, there were significant correlations for INL perfusion and improvement of 6MWT (r=0.35, P=0.03 and for HI and improvement in FEV1 (r=0.45, P=0.001. This study reveals new attributes that associate with positive outcomes for patient selection prior to ELVR

  12. Endotracheal tube defects: Hidden causes of airway obstruction

    Directory of Open Access Journals (Sweden)

    Sofi Khalid

    2010-01-01

    Full Text Available Manufacturing defects of endotracheal tube (ETT are still encountered in anesthesia practice. Many such defects go unnoticed during routine inspection prior to their use. Such defects in ETT may lead to partial or complete airway obstruction in an intubated patient. We report a case of partial airway obstruction with a prepacked, single use, uncuffed ETT due to a manufacturing defect in the form of a plastic meniscus at the distal end of the tube. This case report highlights the significance of standard monitoring of ventilation and the role of a vigilant clinician in detecting such defects in avoiding critical events as can arise from the use of such defective ETTs. It also emphasizes the need for double checking ETTs prior to their use.

  13. To Find a Better Dosimetric Parameter in the Predicting of Radiation-Induced Lung Toxicity Individually: Ventilation, Perfusion or CT based.

    Science.gov (United States)

    Xiao, Lin-Lin; Yang, Guoren; Chen, Jinhu; Wang, Xiaohui; Wu, Qingwei; Huo, Zongwei; Yu, Qingxi; Yu, Jinming; Yuan, Shuanghu

    2017-03-15

    This study aimed to find a better dosimetric parameter in predicting of radiation-induced lung toxicity (RILT) in patients with non-small cell lung cancer (NSCLC) individually: ventilation(V), perfusion (Q) or computerized tomography (CT) based. V/Q single-photon emission computerized tomography (SPECT) was performed within 1 week prior to radiotherapy (RT). All V/Q imaging data was integrated into RT planning system, generating functional parameters based on V/Q SPECT. Fifty-seven NSCLC patients were enrolled in this prospective study. Fifteen (26.3%) patients underwent grade ≥2 RILT, the remaining forty-two (73.7%) patients didn't. Q-MLD, Q-V20, V-MLD, V-V20 of functional parameters correlated more significantly with the occurrence of RILT compared to V20, MLD of anatomical parameters (r = 0.630; r = 0.644; r = 0.617; r = 0.651 vs. r = 0.424; r = 0.520 p < 0.05, respectively). In patients with chronic obstructive pulmonary diseases (COPD), V functional parameters reflected significant advantage in predicting RILT; while in patients without COPD, Q functional parameters reflected significant advantage. Analogous results were existed in fractimal analysis of global pulmonary function test (PFT). In patients with central-type NSCLC, V parameters were better than Q parameters; while in patients with peripheral-type NSCLC, the results were inverse. Therefore, this study demonstrated that choosing a suitable dosimetric parameter individually can help us predict RILT accurately.

  14. Suspected acute pulmonary emboli: cost-effectiveness of chest helical computed tomography versus a standard diagnostic algorithm incorporating ventilation-perfusion scintigraphy

    International Nuclear Information System (INIS)

    Larcos, G.; Chi, K.K.G.; Berry, G.; Westmead Hospital, Sydney, NSW; Shiell, A.

    2000-01-01

    There is a controversy regarding the investigation of patients with suspected acute pulmonary embolism (PE). To compare the cost-effectiveness of alternative methods of diagnosing acute PE, chest helical computed tomography (CT) alone and in combination with venous ultrasound (US) of legs and pulmonary angiography (PA) were compared to a conventional algorithm using ventilation-perfusion (V/Q) scintigraphy supplemented in selected cases by US and PA. A decision-analytical model was constructed to model the costs and effects of the three diagnostic strategies in a hypothetical cohort of 1000 patients each. Transition probabilities were based on published data. Life years gained by each strategy were estimated from published mortality rates. Schedule fees were used to estimate costs. The V/Q protocol is both more expensive and more effective than CT alone resulting in 20.1 additional lives saved at a (discounted) cost of $940 per life year gained. An additional 2.5 lives can be saved if CT replaces V/Q scintigraphy in the diagnostic algorithm but at a cost of $23,905 per life year saved. It resulted that the more effective diagnostic strategies are also more expensive. In patients with suspected PE, the incremental cost-effectiveness of the V/Q based strategy over CT alone is reasonable in comparison with other health interventions. The cost-effectiveness of the supplemented CT strategy is more questionable. Copyright (2000) The Australasian College of Physicians

  15. The asymmetric facial skin perfusion distribution of Bell's palsy discovered by laser speckle imaging technology.

    Science.gov (United States)

    Cui, Han; Chen, Yi; Zhong, Weizheng; Yu, Haibo; Li, Zhifeng; He, Yuhai; Yu, Wenlong; Jin, Lei

    2016-01-01

    Bell's palsy is a kind of peripheral neural disease that cause abrupt onset of unilateral facial weakness. In the pathologic study, it was evidenced that ischemia of facial nerve at the affected side of face existed in Bell's palsy patients. Since the direction of facial nerve blood flow is primarily proximal to distal, facial skin microcirculation would also be affected after the onset of Bell's palsy. Therefore, monitoring the full area of facial skin microcirculation would help to identify the condition of Bell's palsy patients. In this study, a non-invasive, real time and full field imaging technology - laser speckle imaging (LSI) technology was applied for measuring facial skin blood perfusion distribution of Bell's palsy patients. 85 participants with different stage of Bell's palsy were included. Results showed that Bell's palsy patients' facial skin perfusion of affected side was lower than that of the normal side at the region of eyelid, and that the asymmetric distribution of the facial skin perfusion between two sides of eyelid is positively related to the stage of the disease (P Bell's palsy patients, and we discovered that the facial skin blood perfusion could reflect the stage of Bell's palsy, which suggested that microcirculation should be investigated in patients with this neurological deficit. It was also suggested LSI as potential diagnostic tool for Bell's palsy.

  16. Important parameters in the detection of left main trunk disease using stress myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Shiba, Chie; Chikamori, Taishiro; Hida, Satoshi

    2009-01-01

    We sought noninvasively to diagnose left main trunk (LMT) disease using myocardial perfusion imaging (MPI). Five hundred and eight patients with suspected coronary artery disease (CAD) underwent both stress MPI and coronary angiography. The extent and severity of perfusion abnormalities were assessed using a 20-segment model. In addition, perfusion defects in both left anterior descending and left circumflex arterial territories were defined as a left main (LM) pattern defect, and those in 3-coronary arterial territories as a 3-vessel pattern defect. In 42 patients with LMT disease, a summed stress score (19.4±10.0 vs. 13.5±10.0; p<0.0001) and a summed rest score (12.1±9.7 vs. 7.0±7.8; p=0.002) were greater than in 466 patients without LMT disease, while a summed difference score was similar (7.3±7.7 vs. 6.5±6.1; p=NS). The prevalence of an LM-pattern defect was low in both groups (12% vs. 8%; p=NS). However, a 3-vessel pattern defect (33% vs. 7%; p<0.0001), lung uptake of radiotracers (38% vs. 11%; p<0.0001), and transient ischemic dilation (31% vs. 13%; p=0.003) were more frequently observed in patients with LMT disease than in those without. Logistic regression analysis showed that a 3-vessel pattern defect (odds ratio (OR)=3.5, 95% confidence interval (CI)=1.4-8.8; p=0.007), lung uptake of radiotracers (OR=2.5, 95% CI=1.1-5.7; p=0.03), and previous myocardial infarction (MI) (OR=2.4, 95% CI=1.0-5.7; p=0.05) were the most important parameters to detect LMT disease. After excluding 163 patients with previous MI, a repeat analysis revealed that lung uptake of radiotracers (OR=8.2, 95% CI=2.3-29.2; p=0.001) and an LM-pattern defect (OR=6.3, 95% CI=1.4-27.2; p<0.02) were independent predictors for LMT disease. In the identification of LMT disease, lung uptake of radiotracers was a single best parameter, which was independent of the presence or absence of previous MI. (author)

  17. Constant-flow ventilation in canine experimental pulmonary emphysema.

    Science.gov (United States)

    Hachenberg, T; Wendt, M; Meyer, J; Struckmeier, O; Lawin, P

    1989-07-01

    The efficacy of constant-flow ventilation (CFV) was investigated in eight mongrel dogs before (control-phase) and after development of papain-induced panlobular emphysema (PLE-phase). For CFV, heated, humidified and oxygen-enriched air was continuously delivered via two catheters positioned within each mainstem bronchus at flow rates (V) of 0.33, 0.5 and 0.66 l/s. Data obtained during intermittent positive pressure ventilation (IPPV) served as reference. In the control-phase, Pao2 was lower (P less than or equal to 0.05) and alveolo-arterial O2 difference (P(A-a)O2) was higher (P less than or equal to 0.01) during CFV at all flow rates when compared with IPPV. This may be due to inhomogeneities of intrapulmonary gas distribution and increased ventilation-perfusion (VA/Q) mismatching. Paco2 and V showed a hyperbolic relationship; constant normocapnia (5.3 kPa) was achieved at 0.48 +/- 0.21 l/s (V53). Development of PLE resulted in an increase of functional residual capacity (FRC), residual volume (RV) and static compliance (Cstat) (P less than or equal to 0.05). PaO2 had decreased and P(A-a)O2 had increased (P less than or equal to 0.05), indicating moderate pulmonary dysfunction. Oxygenation during CFV was not significantly different in the PLE-phase when compared with the control-phase. Paco2 and V showed a hyperbolic relationship and V5.3 was even lower than in the control-group (0.42 +/- 0.13 l/s). In dogs with emphysematous lungs CFV maintains sufficient gas exchange. This may be due to preferential ventilation of basal lung units, thereby counterbalancing the effects of impaired lung morphometry and increased airtrapping. Conventional mechanical ventilation is more effective in terms of oxygenation and CO2-elimination.

  18. Norwegian Pitched Roof Defects

    Directory of Open Access Journals (Sweden)

    Lars Gullbrekken

    2016-06-01

    Full Text Available The building constructions investigated in this work are pitched wooden roofs with exterior vertical drainpipes and wooden load-bearing system. The aim of this research is to further investigate the building defects of pitched wooden roofs and obtain an overview of typical roof defects. The work involves an analysis of the building defect archive from the research institute SINTEF Building and Infrastructure. The findings from the SINTEF archive show that moisture is a dominant exposure factor, especially in roof constructions. In pitched wooden roofs, more than half of the defects are caused by deficiencies in design, materials, or workmanship, where these deficiencies allow moisture from precipitation or indoor moisture into the structure. Hence, it is important to increase the focus on robust and durable solutions to avoid defects both from exterior and interior moisture sources in pitched wooden roofs. Proper design of interior ventilation and vapour retarders seem to be the main ways to control entry from interior moisture sources into attic and roof spaces.

  19. IMPACT UPON ENVIRONMENT PROTECTION DUE TO DEFECTIVELY PRODUCED AND OPERATED VENTILATION SYSTEMS IN FOOD INDUSTRY

    Directory of Open Access Journals (Sweden)

    Izabela Małecka

    2014-10-01

    Full Text Available Mechanical (air-conditioning ventilation systems and equipment in the food industry may transfer various pathogenic bacteria causing, for instance, pneumonia (Legionellosis. Microclimate parameters in manufacturing shops felt by people are affected by: human factors (health, individual temperature perception etc, and non-human factors (air physical parameters, air freshness and cleanliness etc.. Microbiological contamination of process equipment, machines and systems such as ventilation and air-conditioning equipment causes growth of pathogenic bacteria. The amount of air supplied and removed from a room depends on its use and load of odours and hazardous material. As a result of dew point formation in ventilation systems may appear the so-called air-borne condensation nuclei on which steam settles when the air gets oversaturated. The air flow rate has a material influence upon comfortable conditions in human inhabited zones. In manufacturing shops where the highest air quality is a priority, radial disinfection by means of catalytic ionization is applied. In food industry manufacturing shops of higher microbiological standard, ventilation systems based on air re-circulation should not be used.

  20. Simultaneous measurement of pO2 and perfusion in the rabbit kidney in vivo.

    Science.gov (United States)

    O'Connor, Paul M; Anderson, Warwick P; Kett, Michelle M; Evans, Roger G

    2007-01-01

    Recently, a combined probe has been developed capable of simultaneous measurement of local tissue pO2 (fluorescence oximetry) and microvascular perfusion (laser Doppler flux) within the same local region. The aim of the current study was to test the utility of these combined probes to measure pO2 and perfusion in the kidney. Studies were performed in anesthetized, artificially ventilated rabbits (n=7). Baseline measurements of renal medullary perfusion and pO2 obtained using combined probes (537 +/- 110 units & 28.7 +/- 6.l mmHg, respectively) were indistinguishable from those obtained using independent probes (435 +/- 102 units & 26.9 +/- 6.4 mmHg). Baseline measurements of renal cortical pO2 were also similar between combined (9.7 +/- 1.6 mmHg) and independent probes (9.5 +/- 2.3 mmHg). Baseline levels of cortical perfusion however, were significantly greater when measured using independent probes (1130 +/- 114 units) compared to combined probes (622 +/- 59 units; P pO2 resulting from graded stimulation of the renal nerves were not significantly different when measured using combined probes to those obtained using independent probes. We conclude that combined probes are equally suitable to independent probes for tissue pO2 and microvascular perfusion measurement in the kidney. Our results raise some concerns regarding the accuracy of these OxyLite fluorescence probes for pO2 measurement in the kidney, particularly within the renal cortex.

  1. Evaluation of pulmonary emphysema by the fused image of CT image and ventilation SPECT image

    International Nuclear Information System (INIS)

    Okuda, Ituko; Maruno, Hiromasa; Mori, Kazuaki; Kohno, Tadashi; Kokubo, Takashi

    2007-01-01

    We evaluated pulmonary emphysema using a diagnostic device that could obtain a CT image, a ventilation single photon emission computed tomography (SPECT) image and a lung perfusion SPECT image in one examination. The fused image made from the CT image and SPECT image had very little position gap between images, and the precision was high. From the fused image, we were able to detect the areas in which emphysematous change was the most marked in the CT image, while the accumulation decrease was most remarkable in the ventilation SPECT image. Thus it was possible to obtain an accurate status of pulmonary emphysema, and our method was regarded as a useful technique. (author)

  2. Application of myocardial perfusion quantitative imaging for the evaluation of therapeutic effect in canine with myocardial infarction

    International Nuclear Information System (INIS)

    Liang Hong; Chen Ju; Liu Sheng; Zeng Shiquan

    2000-01-01

    Myocardial blood perfusion (MBP) ECT and quantitative analysis were performed in 10 canines with experimental acute myocardial infarct (AMI). The accuracy of main myocardial quantitative index, including defect volume (DV) and defect fraction (DF), was estimated and correlated with histochemical staining (HS) of infarcted area. Other 21/AMI canines were divided into Nd:YAG laser trans-myocardial revascularization treated group LTMR and control group. All canines were performed MBP ECT after experimental AMI. Results found that the infarcted volume (IV) measured by HS has well correlated (r 0.88) with DV estimated by myocardial quantitative analysis. But the DF values calculated by both methods was not significantly different (t = 1.28 P > 0.05). In LTMR group 27.5% +- 3.9%, the DF is smaller than control group 32.1% +- 4.6% (t = 2.49 P 99m Tc-MIBI myocardial perfusion SPECT and quantitative study can accurately predict the myocardial blood flow and magnitude of injured myocardium. Nd:YAG LTMR could improve myocardial blood perfusion of ischemic myocardium and decrease effectively the infarct areas

  3. Altered myocardial perfusion during dobutamine stress testing in silent versus symptomatic myocardial ischaemia assessed by quantitative MIBI SPET imaging

    International Nuclear Information System (INIS)

    Elhendy, A.; Geleijnse, M.L.; Roelandt, J.R.T.C.; Cornel, J.H.; Domburg, R.T van; Reijs, A.E.M.; Nierop, P.R.; Fioretti, P.M.

    1996-01-01

    The aim of the study was to compare the extent and severity of reversible underperfusion in silent versus painful myocardial ischaemia during the dobutamine stress test. A consecutive series of 85 patients with significant coronary artery disease and reversible perfusion defects on technetium-99m methoxyisobutylisonitrile single-photon emission tomography performed at rest and during high-dose dobutamine stress (up to 40 μg kg -1 min -1 ) were studied. The left ventricle was divided into six segments. An ischaemic perfusion score was derived quantitatively by subtracting the rest from the stress defect score. Patients with multivessel disease had a higher ischaemic score (610±762 vs 310±411, P<0.05) and a higher number of reversible perfusion defects (2.1±1.2 vs 1.1±0.8, P<0.01) than patients with single-vessel disease. Typical angina occurred in 37 patients (44%) during the test. There was no significant difference between patients with and patients without angina with respecft to age, gender, peak rate-pressure product, prevalence of previous myocardial infarction, diabetes mellitus, multivessel disease or number of stenotic coronary arteries. Stress, rest and ischaemic scores as well as the number and distribution of reversible defects were not different in patients with and patients without angina. Patients with angina more frequently had a history of typical angina before the test (43% vs 17%, P<0.01) and ST-segment depression during the test (54% vs 25%, P<0.01). It is concluded that in patients with coronary artery disease and ischaemia detected by dobutamine scintigraphy, the extent and severity of coronary artery disease and myocardial perfusion abnormalities are similar with or without angina during stess testing. (orig.)

  4. Dynamic CT Perfusion Imaging for the Detection of Crossed Cerebellar Diaschisis in Acute Ischemic Stroke

    International Nuclear Information System (INIS)

    Jeon, Young Wook; Kim, Seo Hyun; Lee, Ji Young; Whang, Kum; Kim, Myung Soon; Kim, Young Ju; Lee, Myeong Sub; Brain Reserch Group

    2012-01-01

    Although the detection of crossed cerebellar diaschisis (CCD) by means of different imaging modalities is well described, little is known about its diagnosis by computed tomography perfusion (CTP) imaging. We investigated the detection rate of CCD by CTP imaging and the factors related to CCD on CTP images in patients with acute ischemic stroke. CT perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time-to-peak (TTP) obtained from 81 consecutive patients affected by an acute ischemic stroke were retrospectively reviewed. Whole-brain perfusion maps were obtained with a multichannel CT scanner using the toggling-table technique. The criteria for CCD was a unilateral supratentorial ischemic lesion and an accompanying decrease in perfusion of the contralateral cerebellar hemisphere on the basis of CTP maps by visual inspection without a set threshold. Maps were quantitatively analyzed in CCD positive cases. The criteria for CCD were fulfilled in 25 of the 81 cases (31%). Detection rates per CTP map were as follows: MTT (31%) > TTP (21%) > CBF (9%) > CBV (6%). Supratentorial ischemic volume, degree of perfusion reduction, and infratentorial asymmetry index correlated strongly (R, 0.555-0.870) and significantly (p < 0.05) with each other in CCD-positive cases. It is possible to detect CCD on all four of the CTP-based maps. Of these maps, MTT is most sensitive in detecting CCD. Our data indicate that CTP imaging is a valid tool for the diagnosis of CCD in patients affected by an acute hemispheric stroke.

  5. Withholding or Continuing Beta-Blocker Treatment Before Dipyridamole Myocardial Perfusion Imaging for the Diagnosis of Coronary Artery Disease? a Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Babak Fallahi

    2013-01-01

    Full Text Available Although it has been shown that acute beta-blocker administration may reduce the presence or severity of myocardial perfusion defects with dipyridamole stress, little information is available about the potential effect of chronic beta-blocker treatment on the sensitivity of dipyridamole myocardial perfusion imaging (DMPI.Methods As a randomized clinical trial, one hundred twenty patients (103 male and 17 female with angiographically confirmed CAD who were on long-term beta blocker therapy ([greater than or equal to]3 months enrolled in a randomized clinical trial study. The patients were allocated into two groups: Group A (n=60 in whom the beta-blocker agent was discontinued for 72h before DMPI and Group B (n=60 without discontinuation of beta-blockers prior to DMPI.ResultsNo significant difference was noted between the groups concerning age, sex, type of the injected radiotracer and number of involved coronary vessels. The mean rank of total perfusion scores for whole myocardium (irrespective of reversibility or irreversibility in group B was not significantly different from that of group A, (65.75 vs. 55.25, P=0.096. Regarding the only irreversible perfusion defects, the mean rank of perfusion score in group B was higher than that of group A for whole myocardium (72 vs. 49, P=0.0001; however, no difference was noted between two groups for only reversible perfusion defects (61.0 vs. 60.0, P=0.898. The overall sensitivity of DMPI for the diagnosis of CAD in group A (91.7% was not statistically different from group B (90%.ConclusionBeta-blocker withholding before DMPI did not generally affect the sensitivity of the test for the diagnostic purposes in our study. Thus, beta-blocker withdrawal for just the purpose of diagnostic imaging is not mandatory particularly when medication discontinuation may cause the patients to face increased risk of heart events.

  6. Myocardial perfusion alterations observed months after radiotherapy are related to the cellular damage

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, I.; Sonmez, B. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Nuclear Medicine; Sezen, O.; Zengin, A.Y.; Bahat, Z. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Radiation Oncology; Yenilmez, E.; Yulug, E. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Histology and Embryology; Abidin, I. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Biophysics

    2010-07-01

    Myocardial perfusion scintigraphy (MPS) is one of the widely used tools to follow developing radiation-induced heart disease (RIHD). But the clinical significance of MPS defects has not been fully understood. We have investigated the biodistribution alterations related to perfusion defects following radiotherapy (RT) and showed coexisting morphological changes. Animals, methods: A total of 18 Wistar rats were divided into three groups (1 control and 2 irradiated groups). A single cardiac 20 Gy radiation dose was used to induce long term cardiac defects. Biodistribution studies with technetium ({sup 99m}Tc) sestamibi and histological evaluations were performed 4 and 6 months after irradiation. The percent radioactivity (%ID/g) was calculated for each heart. For determination of the myocardial damage, positive apoptotic cardiomyocytes, myocardial cell degeneration, myocardial fibrosis, vascular damage and ultrastructural structures were evaluated. Results: Six months after treatment, a significant drop of myocardial uptake was observed (p < 0.05). Irradiation-induced apoptosis rose within the first 4 months after radiation treatment and were stayed elevated until the end of the observation period (p < 0.05). Also, the irradiation has induced myocardial degeneration, perivascular and interstitial fibrosis in the heart at the end of six and four months (p < 0.01). The severity and extent of myocardial injury has became more evident at the end of six month (p < 0.05). At ultrastructural level, prominent changes have been observed in the capillary endothelial and myocardial cells. Conclusion: Our findings suggest that the reduced rest myocardial perfusion, occuring months after the radiation, indicates a serious myocard tissue damage which is characterized by myocardial degeneration and fibrosis. (orig.)

  7. Myocardial perfusion alterations observed months after radiotherapy are related to the cellular damage

    International Nuclear Information System (INIS)

    Dogan, I.; Sonmez, B.; Sezen, O.; Zengin, A.Y.; Bahat, Z.; Yenilmez, E.; Yulug, E.; Abidin, I.

    2010-01-01

    Myocardial perfusion scintigraphy (MPS) is one of the widely used tools to follow developing radiation-induced heart disease (RIHD). But the clinical significance of MPS defects has not been fully understood. We have investigated the biodistribution alterations related to perfusion defects following radiotherapy (RT) and showed coexisting morphological changes. Animals, methods: A total of 18 Wistar rats were divided into three groups (1 control and 2 irradiated groups). A single cardiac 20 Gy radiation dose was used to induce long term cardiac defects. Biodistribution studies with technetium ( 99m Tc) sestamibi and histological evaluations were performed 4 and 6 months after irradiation. The percent radioactivity (%ID/g) was calculated for each heart. For determination of the myocardial damage, positive apoptotic cardiomyocytes, myocardial cell degeneration, myocardial fibrosis, vascular damage and ultrastructural structures were evaluated. Results: Six months after treatment, a significant drop of myocardial uptake was observed (p < 0.05). Irradiation-induced apoptosis rose within the first 4 months after radiation treatment and were stayed elevated until the end of the observation period (p < 0.05). Also, the irradiation has induced myocardial degeneration, perivascular and interstitial fibrosis in the heart at the end of six and four months (p < 0.01). The severity and extent of myocardial injury has became more evident at the end of six month (p < 0.05). At ultrastructural level, prominent changes have been observed in the capillary endothelial and myocardial cells. Conclusion: Our findings suggest that the reduced rest myocardial perfusion, occuring months after the radiation, indicates a serious myocard tissue damage which is characterized by myocardial degeneration and fibrosis. (orig.)

  8. Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks

    Science.gov (United States)

    Ghaly, Michael; Du, Yong; Links, Jonathan M.; Frey, Eric C.

    2016-03-01

    In SPECT imaging, collimators are a major factor limiting image quality and largely determine the noise and resolution of SPECT images. In this paper, we seek the collimator with the optimal tradeoff between image noise and resolution with respect to performance on two tasks related to myocardial perfusion SPECT: perfusion defect detection and joint detection and localization. We used the Ideal Observer (IO) operating on realistic background-known-statistically (BKS) and signal-known-exactly (SKE) data. The areas under the receiver operating characteristic (ROC) and localization ROC (LROC) curves (AUCd, AUCd+l), respectively, were used as the figures of merit for both tasks. We used a previously developed population of 54 phantoms based on the eXtended Cardiac Torso Phantom (XCAT) that included variations in gender, body size, heart size and subcutaneous adipose tissue level. For each phantom, organ uptakes were varied randomly based on distributions observed in patient data. We simulated perfusion defects at six different locations with extents and severities of 10% and 25%, respectively, which represented challenging but clinically relevant defects. The extent and severity are, respectively, the perfusion defect’s fraction of the myocardial volume and reduction of uptake relative to the normal myocardium. Projection data were generated using an analytical projector that modeled attenuation, scatter, and collimator-detector response effects, a 9% energy resolution at 140 keV, and a 4 mm full-width at half maximum (FWHM) intrinsic spatial resolution. We investigated a family of eight parallel-hole collimators that spanned a large range of sensitivity-resolution tradeoffs. For each collimator and defect location, the IO test statistics were computed using a Markov Chain Monte Carlo (MCMC) method for an ensemble of 540 pairs of defect-present and -absent images that included the aforementioned anatomical and uptake variability. Sets of test statistics were

  9. Pulmonary perfusion scintigraphy in the evaluation of the severity of bronchopulmonary dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Soler, C. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain); Figueras, J. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain)]|[Servicio de Neonatologia, Hospital Clinico, Barcelona (Spain); Roca, I. [Nuclear Medicine Unit, Autonomous Univ. of Barcelona (Spain); Perez, J.M. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain); Jimenez, R. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain)

    1997-01-01

    Objective. The objectives of this study were to analyze the changes in pulmonary perfusion in bronchopulmonary dysplasia (BPD) and to assess the advantages of this method in evaluating the severity of BPD. Patients and methods. The study group was made up of 10 children with BPD, matched with a control group of 12 children. The criteria for matching were birth weight, gestational age and need for ventilation for more than 3 days. Clinical and roentgenographic scoring systems were applied on the 21st day of life. At 6 months of corrected age, clinical evolutive severity was evaluated and a pulmonary perfusion scintigraphy using technetium-99 was performed in each child. The scintigraphic findings were classified in five categories ranging from normal to severely affected, depending on the degree and localization of perfusion abnormalities. Another score was obtained by assigning a value from 1 to 5 to each pulmonary lobe, depending on the concentration of the tracer. Results. The study of clinical, roentgenographic and evolutive scores always showed higher values in children with BPD, with good correlation between methods (P < 0.001). In the BPD group, abnormal lung perfusion patterns were more frequent and more severe (P < 0.05), the lobe scoring was higher (P < 0.05), and a lower count rate was found (P < 0.01). Conclusion. Pulmonary scintigraphy is a useful technique in evaluating the severity of BPD. (orig.). With 1 fig., 3 tabs.

  10. Pulmonary perfusion scintigraphy in the evaluation of the severity of bronchopulmonary dysplasia

    International Nuclear Information System (INIS)

    Soler, C.; Figueras, J.; Roca, I.; Perez, J.M.; Jimenez, R.

    1997-01-01

    Objective. The objectives of this study were to analyze the changes in pulmonary perfusion in bronchopulmonary dysplasia (BPD) and to assess the advantages of this method in evaluating the severity of BPD. Patients and methods. The study group was made up of 10 children with BPD, matched with a control group of 12 children. The criteria for matching were birth weight, gestational age and need for ventilation for more than 3 days. Clinical and roentgenographic scoring systems were applied on the 21st day of life. At 6 months of corrected age, clinical evolutive severity was evaluated and a pulmonary perfusion scintigraphy using technetium-99 was performed in each child. The scintigraphic findings were classified in five categories ranging from normal to severely affected, depending on the degree and localization of perfusion abnormalities. Another score was obtained by assigning a value from 1 to 5 to each pulmonary lobe, depending on the concentration of the tracer. Results. The study of clinical, roentgenographic and evolutive scores always showed higher values in children with BPD, with good correlation between methods (P < 0.001). In the BPD group, abnormal lung perfusion patterns were more frequent and more severe (P < 0.05), the lobe scoring was higher (P < 0.05), and a lower count rate was found (P < 0.01). Conclusion. Pulmonary scintigraphy is a useful technique in evaluating the severity of BPD. (orig.). With 1 fig., 3 tabs

  11. Automated pulmonary lobar ventilation measurements using volume-matched thoracic CT and MRI

    Science.gov (United States)

    Guo, F.; Svenningsen, S.; Bluemke, E.; Rajchl, M.; Yuan, J.; Fenster, A.; Parraga, G.

    2015-03-01

    Objectives: To develop and evaluate an automated registration and segmentation pipeline for regional lobar pulmonary structure-function measurements, using volume-matched thoracic CT and MRI in order to guide therapy. Methods: Ten subjects underwent pulmonary function tests and volume-matched 1H and 3He MRI and thoracic CT during a single 2-hr visit. CT was registered to 1H MRI using an affine method that incorporated block-matching and this was followed by a deformable step using free-form deformation. The resultant deformation field was used to deform the associated CT lobe mask that was generated using commercial software. 3He-1H image registration used the same two-step registration method and 3He ventilation was segmented using hierarchical k-means clustering. Whole lung and lobar 3He ventilation and ventilation defect percent (VDP) were generated by mapping ventilation defects to CT-defined whole lung and lobe volumes. Target CT-3He registration accuracy was evaluated using region- , surface distance- and volume-based metrics. Automated whole lung and lobar VDP was compared with semi-automated and manual results using paired t-tests. Results: The proposed pipeline yielded regional spatial agreement of 88.0+/-0.9% and surface distance error of 3.9+/-0.5 mm. Automated and manual whole lung and lobar ventilation and VDP were not significantly different and they were significantly correlated (r = 0.77, p pulmonary structural-functional maps with high accuracy and robustness, providing an important tool for image-guided pulmonary interventions.

  12. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Nuclear Medicine, University of l`Aquila (Italy); Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L. [Department of Clinical Medicine, University ``La Sapienza``, Rome (Italy); Danieli, R.; Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1999-07-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with {sup 99m}Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (``reverse redistribution pattern``). Coronary angiography was performed in eight patients with positive {sup 99m}Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that {sup 99m}Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole {sup 99m}Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.) With 2 figs., 2 tabs., 21 refs.

  13. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Schillaci, O.; Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L.; Danieli, R.; Scopinaro, F.

    1999-01-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with 99m Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (''reverse redistribution pattern''). Coronary angiography was performed in eight patients with positive 99m Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that 99m Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole 99m Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.)

  14. Prone positioning ventilation for treatment of acute lung injury and acute respiratory distress syndrome.

    Science.gov (United States)

    Lan, Mei-juan; He, Xiao-di

    2009-08-01

    Patients who are diagnosed with acute lung injury/acute respiratory distress syndrome (ALI/ARDS) usually have ventilation-perfusion mismatch, severe decrease in lung capacity, and gas exchange abnormalities. Health care workers have implemented various strategies in an attempt to compensate for these pathological alterations. By rotating patients with ALI/ARDS between the supine and prone position, it is possible to achieve a significant improvement in PaO2/FiO2, decrease shunting and therefore improve oxygenation without use of expensive, invasive and experimental procedures. Prone positioning is a safe and effective way to improve ventilation when conventional strategies fail to initiate a patient response. Because a specific cure for ARDS is not available, the goal is to support the patients with therapies that cause the least amount of injury while the lungs have an opportunity to heal. Based on current data, a trial of prone positioning ventilation should be offered to the patients who have ALI/ARDS in the early course of the disease. Published studies exhibit substantial heterogeneity in clinical results, suggesting that an adequately sized study optimizing the duration of proning ventilation strategy is warranted to enable definitive conclusions to be drawn.

  15. Acute CT perfusion changes in seizure patients presenting to the emergency department with stroke-like symptoms: correlation with clinical and electroencephalography findings

    International Nuclear Information System (INIS)

    Payabvash, S.; Oswood, M.C.; Truwit, C.L.; McKinney, A.M.

    2015-01-01

    Aim: To determine acute computed tomography perfusion (CTP) changes in seizure patients presenting with stroke-like symptoms and to correlate those changes with clinical presentation and electroencephalography (EEG). Materials and methods: The medical records of all patients who presented to the emergency department with acute stroke-like symptoms and underwent CTP (n=1085) over a 5.5-year period were reviewed. Patients were included who had primary seizure as the final diagnosis, and underwent CTP within 3 hours of symptom onset. A subset of patients had a follow-up EEG within 7 days. The perfusion changes and EEG findings were compared between different clinical presentations. Results: Eighteen of 1085 patients (1.7%) who underwent CTP following an acute stroke-like presentation were included. The abnormality on CTP was usually focal, unilateral hyperperfusion — increased relative cerebral blood flow (rCBF) and volume (rCBV) (n=14/18), which most often affected the temporal lobe. Those patients who presented with a motor or speech deficit (n=12) had a higher temporal lobe rCBV, and rCBF, and lower relative mean transit time (rMTT) compared to those with non-focal neurological deficit at presentation. Early EEG was available in 13 patients; a sharp-spike epileptiform EEG discharge pattern (n=5) was associated with higher temporal lobe ipsilateral rCBF and rCBV, and lower rMTT on admission CTP examination. Conclusion: Seizure patients who present with a unilateral motor or speech deficit most commonly have contralateral hyperperfusion in the corresponding eloquent brain regions on the acute-stage CTP examination. In such patients, epileptiform discharges on the early follow-up EEG are associated with ipsilateral hyperperfusion on the admission CTP. -- Highlights: •Seizure patients with stroke-mimic symptoms show contralateral hyperperfusion on acute phase CTP (<3 hours of onset). •Seizure patients with unilateral paralysis/aphasia showed asymmetric perfusion

  16. Quantitative analysis of pulmonary perfusion using time-resolved parallel 3D MRI - initial results

    International Nuclear Information System (INIS)

    Fink, C.; Buhmann, R.; Plathow, C.; Puderbach, M.; Kauczor, H.U.; Risse, F.; Ley, S.; Meyer, F.J.

    2004-01-01

    Purpose: to assess the use of time-resolved parallel 3D MRI for a quantitative analysis of pulmonary perfusion in patients with cardiopulmonary disease. Materials and methods: eight patients with pulmonary embolism or pulmonary hypertension were examined with a time-resolved 3D gradient echo pulse sequence with parallel imaging techniques (FLASH 3D, TE/TR: 0.8/1.9 ms; flip angle: 40 ; GRAPPA). A quantitative perfusion analysis based on indicator dilution theory was performed using a dedicated software. Results: patients with pulmonary embolism or chronic thromboembolic pulmonary hypertension revealed characteristic wedge-shaped perfusion defects at perfusion MRI. They were characterized by a decreased pulmonary blood flow (PBF) and pulmonary blood volume (PBV) and increased mean transit time (MTT). Patients with primary pulmonary hypertension or eisenmenger syndrome showed a more homogeneous perfusion pattern. The mean MTT of all patients was 3.3 - 4.7 s. The mean PBF and PBV showed a broader interindividual variation (PBF: 104-322 ml/100 ml/min; PBV: 8 - 21 ml/100 ml). Conclusion: time-resolved parallel 3D MRI allows at least a semi-quantitative assessment of lung perfusion. Future studies will have to assess the clinical value of this quantitative information for the diagnosis and management of cardiopulmonary disease. (orig.) [de

  17. CT arteriography via the right inferior phrenic artery developed parasitic perfusion into the liver

    International Nuclear Information System (INIS)

    Inaba, Yoshitaka; Arai, Yasuaki; Sueyoshi, Satoshi; Yamagami, Takuji; Aramaki, Takeshi; Yamaura, Hidekazu; Matsueda, Kiyoshi; Sasaki, Fumio; Takeuchi, Yoshihito.

    1998-01-01

    The distribution of arterial blood flow via the right inferior phrenic artery (rt-IPA) developing parasitic perfusion into the liver was evaluated by CT arteriography (CTA) in 50 cases with hepatic tumors. In all cases, CTA via rt-IPA showed hyperperfusion area including hepatic tumors in the posterior segment and the caudate lobe of the liver, and adding the left hepatic lobe in cases with hepatic arterial occlusion. In 82% of 33 cases obtained both CTA via rt-IPA and CTA via hepatic artery, the hyperperfusion area on CTA via rt-IPA exactly corresponded to perfusion defect area on CTA via hepatic artery. CTA was much useful for understanding hemodynamics in cases with parasitic perfusion into the liver and it could make transcatheter arterial therapy more effective. (author)

  18. CT arteriography via the right inferior phrenic artery developed parasitic perfusion into the liver

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, Yoshitaka; Arai, Yasuaki; Sueyoshi, Satoshi; Yamagami, Takuji; Aramaki, Takeshi; Yamaura, Hidekazu; Matsueda, Kiyoshi; Sasaki, Fumio [Aichi Cancer Center, Nagoya (Japan); Takeuchi, Yoshihito

    1998-02-01

    The distribution of arterial blood flow via the right inferior phrenic artery (rt-IPA) developing parasitic perfusion into the liver was evaluated by CT arteriography (CTA) in 50 cases with hepatic tumors. In all cases, CTA via rt-IPA showed hyperperfusion area including hepatic tumors in the posterior segment and the caudate lobe of the liver, and adding the left hepatic lobe in cases with hepatic arterial occlusion. In 82% of 33 cases obtained both CTA via rt-IPA and CTA via hepatic artery, the hyperperfusion area on CTA via rt-IPA exactly corresponded to perfusion defect area on CTA via hepatic artery. CTA was much useful for understanding hemodynamics in cases with parasitic perfusion into the liver and it could make transcatheter arterial therapy more effective. (author)

  19. Absence of the spleen(s) in conjoined twins: a diagnostic clue of laterality defects? Radiological study of historical specimens

    NARCIS (Netherlands)

    Oostra, R. J.; Keulen, N.; Jansen, T.; van Rijn, R. R.

    2012-01-01

    Laterality defects are quite common in thoracoileopagus and parapagus dicephalus but rare in other types of conjoined twins. To present the presumed laterality defects in cephalothoracoileopagus and prosopothoracoileopagus conjoined twins, based on the unilateral or bilateral absence or duplication

  20. Cirurgia da catarata infantil unilateral Unilateral pediatric cataract surgery

    Directory of Open Access Journals (Sweden)

    Adriana Maria Drummond Brandão

    2008-04-01

    Full Text Available OBJETIVO: Analisar os resultados visuais de uma série de crianças operadas de catarata unilateral. MÉTODOS: Um estudo retrospectivo foi realizado através da análise de 35 prontuários médicos do Serviço de Catarata Congênita da UNIFESP/EPM. RESULTADOS: Quanto à etiologia, a primeira causa de catarata foi idiopática, a segunda causa foi o trauma e a terceira foi a rubéola congênita. Em 51,4% dos olhos tinham acuidade visual pré-operatória de ausência de fixação. E em 42,8% dos casos operados a acuidade visual final foi igual ou melhor que 20/200. DISCUSSÃO: Embora a cirurgia em catarata unilateral seja motivo de controvérsias entre os oftalmologistas, obteve-se melhora de acuidade visual em número significativo de casos.PURPOSE: To analyze the results in a series of children submitted to unilateral cataract surgery. METHODS: A retrospective study was conducted through the analysis of 35 patient files from the Congenital Cataract Service of UNIFESP/EPM. RESULTS: The main cause of unilateral cataract was idiopathic, the second cause was ocular trauma and the third cause was congenital rubella. Initial visual acuity was very poor in 51.4% of the cases (did not fix or follow, and the best corrected final visual acuity was better than 20/200 in 42.8% of the eyes. DISCUSSION: Although controversial, the surgical treatment of unilateral cataract, in this study, showed improvement in many cases.

  1. Myocardial perfusion imaging for detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Beller, G.A.

    1988-01-01

    Despite the widespread use of the exercise stress test in diagnosing asymptomatic myocardial ischemia, exercise radionuclide imaging remains useful for detecting silent ischemia in numerous patient populations, including those who are totally asymptomatic, those who have chronic stable angina, those who have recovered from an episode of unstable angina or an uncomplicated myocardial infarction, and those who have undergone angioplasty or received thrombolytic therapy. Studies show that thallium scintigraphy is more sensitive than exercise electrocardiography in detecting ischemia, i.e., in part, because perfusion defects occur more frequently than ST depression and before angina in the ischemic cascade. Thallium-201 scintigraphy can be performed to differentiate a true- from a false-positive exercise electrocardiographic test in patients with exercise-induced ST depression and no angina. The development of technetium-labeled isonitriles may improve the accuracy of myocardial perfusion imaging. 11 references

  2. Diagnosis of severe and extensive coronary artery disease using gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Lee, Hyoung Woo; Won, Kyu Chang; Park, Jong Sun; Sin, Dog Gu; Kim, Young Jo; Shim, Bong Sub [College of Medicine, Yeungnam Univ., Taegu (Korea, Republic of)

    1999-07-01

    Left ventricular volumes and ejection fractions constitute important informations in the diagnosis and prognosis of cardiac disease. Aim of the study is to verify if the assessment of left ventricular function and perfusion together by gated myocardial perfusion SPECT is useful for diagnosing severe and extensive CAD. We examined 27 consecutive patients (17 males and 10 females, mean age : 60.1 years) who underwent two day rest/stress Tc-99m MIBI gated SPECT. Stress was done with adenosine. Post-stress gated SPECT was done at 1 hour after an injection of Tc-99m MIBI (740 MBq). All patients underwent coronary angiography after gated SPECT within 1 month. We divided them three groups with single vessel disease, double vessel disease and triple vessel disease or severe proximal left coronary artery stenosis. Extent of Defect (ED), Reversibility of Extent (RE), Severity of Defect (SD) and Severity of Reversibility (SR) were calculated by CEqual program. Post-stress LVEF, Rest LVEF, End-diastolic volume(EDV), End-systolic volume(ESV), Transient Ischemic Dilation (TID) of left ventricle (Post-stress EDV/Rest EDV) were calculated using gated SPECT quantification program. Left ventricle is divided with 18 segments and wall motion was scored (normal=0, mild hypokinesia =1, severe hypokinesia =2, akinesia =3 and dyskinesia =4), and then post-stress summed wall motion score was calculated. Post-stress summed wall motion score and post-stress LVEF were significant differences between three groups ( P <0.01). Extent of defect, Extent of reversibility, Severity of defect and severity of reversibility in Polar map were significant differences between three groups ( P <0.01). Post-stress Transient left ventricular dilatation and test LVEF were not significant differences between three groups ( P > 0.05). The gated SPECT pattern (low post-stress LVEF and post-stress summed wall motion score) add important diagnostic information over ungated perfusion data (high ED, ER and SR and

  3. Structural and perfusion magnetic resonance imaging of the lung in cystic fibrosis

    International Nuclear Information System (INIS)

    Amaxopoulou, Christina; Gnannt, Ralph; Kellenberger, Christian J.; Higashigaito, Kai; Jung, Andreas

    2018-01-01

    Because of its absence of ionising radiation and possibility for obtaining functional information, MRI is promising for assessing lung disease in children who require repetitive imaging for long-term follow-up. To describe MRI findings in children with cystic fibrosis and evaluate semi-quantitative dynamic contrast-enhanced lung perfusion. We retrospectively compared lung MRI in 25 children and young adults with cystic fibrosis (median age 3.7 years) to 12 children (median age 2 years) imaged for other pathologies. MRI at 1.5 T included respiratory-gated sequences and contrast-enhanced lung perfusion imaging. We described and graded any morphologic change. Signal enhancement and time to peak values of perfusion abnormalities were compared to those of normally enhancing lung parenchyma. Frequent findings in patients with cystic fibrosis were bronchial wall thickening (24/25, 96%), areas of consolidation (22/25, 88%), enlarged lymph nodes (20/25, 80%), bronchiectasis (5/25, 20%) and mucus plugging (3/25, 12%). Compared to normally enhancing lung, perfusion defects (21/25, 84%), characterised by decreased enhancement, showed prolonged time to peak. Areas of consolidation showed increased enhancement. While time to peak of procedure-related atelectasis was not significantly different from that of normal lung, disease-related consolidation showed prolonged time to peak (P=0.01). Lung MRI demonstrates structural and perfusion abnormalities in children and young people with cystic fibrosis. Semi-quantitative assessment of dynamic contrast-enhanced perfusion imaging might allow differentiation between procedure-related atelectasis and disease-related consolidation. (orig.)

  4. Structural and perfusion magnetic resonance imaging of the lung in cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Amaxopoulou, Christina; Gnannt, Ralph; Kellenberger, Christian J. [University Children' s Hospital Zuerich, Department of Diagnostic Imaging, Zuerich, CH (Switzerland); University Children' s Hospital Zuerich, Children' s Research Center, Zuerich (Switzerland); Higashigaito, Kai [University Hospital Zuerich, Institute of Diagnostic and Interventional Radiology, Zuerich (Switzerland); Jung, Andreas [University Children' s Hospital Zuerich, Children' s Research Center, Zuerich (Switzerland); University Children' s Hospital Zuerich, Division of Pneumology, Zuerich (Switzerland)

    2018-02-15

    Because of its absence of ionising radiation and possibility for obtaining functional information, MRI is promising for assessing lung disease in children who require repetitive imaging for long-term follow-up. To describe MRI findings in children with cystic fibrosis and evaluate semi-quantitative dynamic contrast-enhanced lung perfusion. We retrospectively compared lung MRI in 25 children and young adults with cystic fibrosis (median age 3.7 years) to 12 children (median age 2 years) imaged for other pathologies. MRI at 1.5 T included respiratory-gated sequences and contrast-enhanced lung perfusion imaging. We described and graded any morphologic change. Signal enhancement and time to peak values of perfusion abnormalities were compared to those of normally enhancing lung parenchyma. Frequent findings in patients with cystic fibrosis were bronchial wall thickening (24/25, 96%), areas of consolidation (22/25, 88%), enlarged lymph nodes (20/25, 80%), bronchiectasis (5/25, 20%) and mucus plugging (3/25, 12%). Compared to normally enhancing lung, perfusion defects (21/25, 84%), characterised by decreased enhancement, showed prolonged time to peak. Areas of consolidation showed increased enhancement. While time to peak of procedure-related atelectasis was not significantly different from that of normal lung, disease-related consolidation showed prolonged time to peak (P=0.01). Lung MRI demonstrates structural and perfusion abnormalities in children and young people with cystic fibrosis. Semi-quantitative assessment of dynamic contrast-enhanced perfusion imaging might allow differentiation between procedure-related atelectasis and disease-related consolidation. (orig.)

  5. Unilateral pulmonary edema after laparoscopic nephrectomy

    Directory of Open Access Journals (Sweden)

    Shreepathi Krishna Achar

    2011-01-01

    Full Text Available Unilateral-dependent pulmonary edema though reported in laparoscopic donor nephrectomies, has not been reported after laparoscopic non-donor nephrectomies. A 75-kg, 61-year-old man, a diagnosed case of right renal cell carcinoma was scheduled for laparoscopic nephrectomy. After establishing general anesthesia, the patient was positioned in the left-sided modified kidney (flank position. During the 5.75-hour procedure, he was hemodynamically stable except for a transient drop in blood pressure immediately after positioning. Intra-abdominal pressure was maintained less than 15 mmHg throughout the procedure. Blood loss was approximately 50 mL and urine output was 100 mL in the first hour followed by a total of 20 mL in the next 4.75 hours. Total fluid received during the procedure included 1.5 L of Ringer′s lactate and 1.0 L of 6% hydroxyethyl starch. After an uneventful procedure he developed respiratory distress in the postoperative period with a radiological evidence of dependent lung edema. Clinical and radiological improvement followed noninvasive ventilation, intravenous diuretics and oxygen therapy.

  6. Ventilator-driven xenon ventilation studies

    International Nuclear Information System (INIS)

    Chilcoat, R.T.; Thomas, F.D.; Gerson, J.I.

    1984-01-01

    A modification of a common commercial Xe-133 ventilation device is described for mechanically assisted ventilation imaging. The patient's standard ventilator serves as the power source controlling the ventilatory rate and volume during the xenon study, but the gases in the two systems are not intermixed. This avoids contamination of the ventilator with radioactive xenon. Supplemental oxygen and positive end-expiratory pressure (PEEP) are provided if needed. The system can be converted quickly for conventional studies with spontaneous respiration

  7. Capability of differentiating smokers with normal pulmonary function from COPD patients: a comparison of CT pulmonary volume analysis and MR perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Li; Xia, Yi; Guan, Yu; Yu, Hong; Liu, Shi-yuan [Changzheng Hospital of the Second Military Medical University, Department of Radiology, Shanghai (China); Zhang, Tie-feng; Li, Bing [Changzheng Hospital of the Second Military Medical University, Department of Respiration Medicine, Shanghai (China)

    2013-05-15

    To compare CT volume analysis with MR perfusion imaging in differentiating smokers with normal pulmonary function (controls) from COPD patients. Sixty-two COPD patients and 17 controls were included. The total lung volume (TLV), total emphysema volume (TEV) and emphysema index (EI) were quantified by CT. MR perfusion evaluated positive enhancement integral (PEI), maximum slope of increase (MSI), maximum slope of decrease (MSD), signal enhancement ratio (SER) and signal intensity ratio (R{sub SI}) of perfusion defects to normal lung. There were 19 class I, 17 class II, 14 class III and 12 class IV COPD patients. No differences were observed in TLV, TEV and EI between control and class I COPD. The control was different from class II, III and IV COPD in TEV and EI. The control was different from each class of COPD in R{sub SI,} MSI, PEI and MSD. Differences were found in R{sub SI} between class I and III, I and IV, and II and IV COPD. Amongst controls, MR detected perfusion defects more frequently than CT detected emphysema. Compared with CT, MR perfusion imaging shows higher potential to distinguish controls from mild COPD and appears more sensitive in identifying abnormalities amongst smokers with normal pulmonary function (controls). (orig.)

  8. Capability of differentiating smokers with normal pulmonary function from COPD patients: a comparison of CT pulmonary volume analysis and MR perfusion imaging

    International Nuclear Information System (INIS)

    Fan, Li; Xia, Yi; Guan, Yu; Yu, Hong; Liu, Shi-yuan; Zhang, Tie-feng; Li, Bing

    2013-01-01

    To compare CT volume analysis with MR perfusion imaging in differentiating smokers with normal pulmonary function (controls) from COPD patients. Sixty-two COPD patients and 17 controls were included. The total lung volume (TLV), total emphysema volume (TEV) and emphysema index (EI) were quantified by CT. MR perfusion evaluated positive enhancement integral (PEI), maximum slope of increase (MSI), maximum slope of decrease (MSD), signal enhancement ratio (SER) and signal intensity ratio (R SI ) of perfusion defects to normal lung. There were 19 class I, 17 class II, 14 class III and 12 class IV COPD patients. No differences were observed in TLV, TEV and EI between control and class I COPD. The control was different from class II, III and IV COPD in TEV and EI. The control was different from each class of COPD in R SI, MSI, PEI and MSD. Differences were found in R SI between class I and III, I and IV, and II and IV COPD. Amongst controls, MR detected perfusion defects more frequently than CT detected emphysema. Compared with CT, MR perfusion imaging shows higher potential to distinguish controls from mild COPD and appears more sensitive in identifying abnormalities amongst smokers with normal pulmonary function (controls). (orig.)

  9. Demand Controlled Ventilation and Classroom Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Davies, Molly [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eliseeva, Ekaterina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hong, Tienzen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-05-01

    This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

  10. Demand controlled ventilation and classroom ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Davies, Molly [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eliseeva, Ekaterina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hong, Tienzen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-06

    This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

  11. Renal perfusion scintiscan

    Science.gov (United States)

    ... Radionuclide renal perfusion scan; Perfusion scintiscan - renal; Scintiscan - renal perfusion Images Kidney anatomy Kidney - blood and urine flow Intravenous pyelogram References Rottenberg G, Andi AC. Renal ...

  12. Perfusão pulmonar anterógrada "versus" retrógrada na preservação pulmonar para transplante em modelo canino de viabilidade pulmonar pós-morte Antegrade versus retrograde lung perfusion in pulmonary preservation for transplantation in a canine model of post-mortem lung viability

    Directory of Open Access Journals (Sweden)

    Jean Carlo Kohmann

    1999-04-01

    Full Text Available A doação pulmonar após parada cardiocirculatória tem sido estudada experimentalmente na obtenção de órgãos para transplante, porém a severa lesão isquêmica/reperfusão exigem métodos de preservação que permitam viabilidade pulmonar. A perfusão do enxerto com solução cristalóide hipotérmica via anterógrada (artéria pulmonar é o método de preservação mais utilizado, porém esta via não perfunde a circulação brônquica, permitindo a retenção sanguínea neste território capaz de desencadear fenômenos de lesão de reperfusão. Isto nos levou a testar os efeitos da perfusão anterógrada versus retrógrada (via átrio esquerdo, capaz de perfundir a circulação brônquica em modelo canino de transplante unilateral cujos pulmões foram extraídos 3 horas após parada cardiorrespiratória. Doze cães doadores foram sacrificados com tiopental sódico e mantidos à temperatura ambiente sob ventilação mecânica durante 3 horas, após as quais os animais foram randomizados e os blocos cardiopulmonares perfundidos via retrógrada (n = 6 ou anterógrada (n = 6 com solução de Euro-Collins modificada e extraídos. Os receptores (n = 12 foram anestesiados, pneumonectomizados e submetidos a transplante pulmonar esquerdo recebendo enxertos perfundidos por via retrógrada (grupo I ou anterógrada (grupo II. Após a reperfusão do enxerto, os animais foram mantidos sob ventilação mecânica (FiO2 = 1 por 6 horas, sendo então sacrificados. Durante este período obtiveram-se medidas hemodinâmicas e gasometrias arteriais, além de amostras de tecido pulmonar para dosagem de ATP intracelular. As medidas hemodinâmicas não diferiram entre os grupos. Nos animais do grupo I a PaO2 e PaCO2 foram superiores às do grupo II (p = 0,016 e p = 0,008, respectivamente. O ATP intracelular não diferiu entre os grupos, embora tenha se reduzido nas amostras obtidas na extração do enxerto do doador quando comparados aos valores após a

  13. Lung scintigraphy in differential diagnosis of peripheral lung cancer and community-acquired pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Krivonogov, Nikolay G., E-mail: kng@cardio-tomsk.ru [Research Institute of Cardiology, Kievskaya Street 111a, Tomsk, 634012 (Russian Federation); Efimova, Nataliya Y., E-mail: efimova@cardio-tomsk.ru; Zavadovsky, Konstantin W.; Lishmanov, Yuri B. [Research Institute of Cardiology, Kievskaya Street 111a, Tomsk, 634012 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation)

    2016-08-02

    Ventilation/perfusion lung scintigraphy was performed in 39 patients with verified diagnosis of community-acquired pneumonia (CAP) and in 14 patients with peripheral lung cancer. Ventilation/perfusion ratio, apical-basal gradients of ventilation (U/L(V)) and lung perfusion (U/L(P)), and alveolar capillary permeability of radionuclide aerosol were determined based on scintigraphy data. The study demonstrated that main signs of CAP were increases in ventilation/perfusion ratio, perfusion and ventilation gradient on a side of the diseased lung, and two-side increase in alveolar capillary permeability rate for radionuclide aerosol. Unlike this, scintigraphic signs of peripheral lung cancer comprise an increase in ventilation/perfusion ratio over 1.0 on a side of the diseased lung with its simultaneous decrease on a contralateral side, normal values of perfusion and ventilation gradients of both lungs, and delayed alveolar capillary clearance in the diseased lung compared with the intact lung.

  14. Lung scintigraphy in differential diagnosis of peripheral lung cancer and community-acquired pneumonia

    Science.gov (United States)

    Krivonogov, Nikolay G.; Efimova, Nataliya Y.; Zavadovsky, Konstantin W.; Lishmanov, Yuri B.

    2016-08-01

    Ventilation/perfusion lung scintigraphy was performed in 39 patients with verified diagnosis of community-acquired pneumonia (CAP) and in 14 patients with peripheral lung cancer. Ventilation/perfusion ratio, apical-basal gradients of ventilation (U/L(V)) and lung perfusion (U/L(P)), and alveolar capillary permeability of radionuclide aerosol were determined based on scintigraphy data. The study demonstrated that main signs of CAP were increases in ventilation/perfusion ratio, perfusion and ventilation gradient on a side of the diseased lung, and two-side increase in alveolar capillary permeability rate for radionuclide aerosol. Unlike this, scintigraphic signs of peripheral lung cancer comprise an increase in ventilation/perfusion ratio over 1.0 on a side of the diseased lung with its simultaneous decrease on a contralateral side, normal values of perfusion and ventilation gradients of both lungs, and delayed alveolar capillary clearance in the diseased lung compared with the intact lung.

  15. Lung ventilation injures areas with discrete alveolar flooding, in a surface tension-dependent fashion.

    Science.gov (United States)

    Wu, You; Kharge, Angana Banerjee; Perlman, Carrie E

    2014-10-01

    With proteinaceous-liquid flooding of discrete alveoli, a model of the edema pattern in the acute respiratory distress syndrome, lung inflation over expands aerated alveoli adjacent to flooded alveoli. Theoretical considerations suggest that the overexpansion may be proportional to surface tension, T. Yet recent evidence indicates proteinaceous edema liquid may not elevate T. Thus whether the overexpansion is injurious is not known. Here, working in the isolated, perfused rat lung, we quantify fluorescence movement from the vasculature to the alveolar liquid phase as a measure of overdistension injury to the alveolar-capillary barrier. We label the perfusate with fluorescence; micropuncture a surface alveolus and instill a controlled volume of nonfluorescent liquid to obtain a micropunctured-but-aerated region (control group) or a region with discrete alveolar flooding; image the region at a constant transpulmonary pressure of 5 cmH2O; apply five ventilation cycles with a positive end-expiratory pressure of 0-20 cmH2O and tidal volume of 6 or 12 ml/kg; return the lung to a constant transpulmonary pressure of 5 cmH2O; and image for an additional 10 min. In aerated areas, ventilation is not injurious. With discrete alveolar flooding, all ventilation protocols cause sustained injury. Greater positive end-expiratory pressure or tidal volume increases injury. Furthermore, we determine T and find injury increases with T. Inclusion of either plasma proteins or Survanta in the flooding liquid does not alter T or injury. Inclusion of 2.7-10% albumin and 1% Survanta together, however, lowers T and injury. Contrary to expectation, albumin inclusion in our model facilitates exogenous surfactant activity. Copyright © 2014 the American Physiological Society.

  16. Comparison of different inspiratory triggering settings in automated ventilators during cardiopulmonary resuscitation in a porcine model.

    Science.gov (United States)

    Tan, Dingyu; Xu, Jun; Shao, Shihuan; Fu, Yangyang; Sun, Feng; Zhang, Yazhi; Hu, Yingying; Walline, Joseph; Zhu, Huadong; Yu, Xuezhong

    2017-01-01

    Mechanical ventilation via automated in-hospital ventilators is quite common during cardiopulmonary resuscitation. It is not known whether different inspiratory triggering sensitivity settings of ordinary ventilators have different effects on actual ventilation, gas exchange and hemodynamics during resuscitation. 18 pigs enrolled in this study were anaesthetized and intubated. Continuous chest compressions and mechanical ventilation (volume-controlled mode, 100% O2, respiratory rate 10/min, and tidal volumes 10ml/kg) were performed after 3 minutes of ventricular fibrillation. Group trig-4, trig-10 and trig-20 (six pigs each) were characterized by triggering sensitivities of 4, 10 and 20 (cmH2O for pressure-triggering and L/min for flow-triggering), respectively. Additionally, each pig in each group was mechanically ventilated using three types of inspiratory triggering (pressure-triggering, flow-triggering and turned-off triggering) of 5 minutes duration each, and each animal matched with one of six random assortments of the three different triggering settings. Blood gas samples, respiratory and hemodynamic parameters for each period were all collected and analyzed. In each group, significantly lower actual respiratory rate, minute ventilation volume, mean airway pressure, arterial pH, PaO2, and higher end-tidal carbon dioxide, aortic blood pressure, coronary perfusion pressure, PaCO2 and venous oxygen saturation were observed in the ventilation periods with a turned-off triggering setting compared to those with pressure- or flow- triggering (all PVentilation with pressure- or flow-triggering tends to induce hyperventilation and deteriorating gas exchange and hemodynamics during CPR. A turned-off patient triggering or a pressure-triggering of 20 cmH2O is preferred for ventilation when an ordinary inpatient hospital ventilator is used during resuscitation.

  17. Effect of scatter and attenuation correction in ROI analysis of brain perfusion scintigraphy. Phantom experiment and clinical study in patients with unilateral cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Bai, J. [Keio Univ., Tokyo (Japan). 21st Century Center of Excellence Program; Hashimoto, J.; Kubo, A. [Keio Univ., Tokyo (Japan). Dept. of Radiology; Ogawa, K. [Hosei Univ., Tokyo (Japan). Dept. of Electronic Informatics; Fukunaga, A.; Onozuka, S. [Keio Univ., Tokyo (Japan). Dept. of Neurosurgery

    2007-07-01

    The aim of this study was to evaluate the effect of scatter and attenuation correction in region of interest (ROI) analysis of brain perfusion single-photon emission tomography (SPECT), and to assess the influence of selecting the reference area on the calculation of lesion-to-reference count ratios. Patients, methods: Data were collected from a brain phantom and ten patients with unilateral internal carotid artery stenosis. A simultaneous emission and transmission scan was performed after injecting {sup 123}I-iodoamphetamine. We reconstructed three SPECT images from common projection data: with scatter correction and nonuniform attenuation correction, with scatter correction and uniform attenuation correction, and with uniform attenuation correction applied to data without scatter correction. Regional count ratios were calculated by using four different reference areas (contralateral intact side, ipsilateral cerebellum, whole brain and hemisphere). Results: Scatter correction improved the accuracy of measuring the count ratios in the phantom experiment. It also yielded marked difference in the count ratio in the clinical study when using the cerebellum, whole brain or hemisphere as the reference. Difference between nonuniform and uniform attenuation correction was not significant in the phantom and clinical studies except when the cerebellar reference was used. Calculation of the lesion-to-normal count ratios referring the same site in the contralateral hemisphere was not dependent on the use of scatter correction or transmission scan-based attenuation correction. Conclusion: Scatter correction was indispensable for accurate measurement in most of the ROI analyses. Nonuniform attenuation correction is not necessary when using the reference area other than the cerebellum. (orig.)

  18. Technetium myocardial perfusion scanning in prerenal transplant evaluation in the United kingdom.

    LENUS (Irish Health Repository)

    Wong, C F

    2008-06-01

    Because death with a functioning graft remains one of the most important causes of long-term renal transplant failure, cardiac risk stratification and screening for coronary artery disease are essential components of pretransplant assessment. Pretransplant screening for occult coronary artery disease in a subset of these patients may improve outcome. The UK follows the European Best practice guideline 1.5.5 E. Although echocardiography, thallium myocardial perfusion scanning (MPS), dobutamine stress echocardiography, and coronary angiography have been suggested as means of cardiovascular assessment, the best means of assessment remains undetermined. Therefore, we investigated the role of 99m technetium sestamibi myocardial perfusion scanning as an assessment tool for identifying those patients with end-stage renal failure at high risk of cardiovascular death after renal transplantation. Retrospectively, we studied 126 patients that had a MPS as part of their pretransplant assessment. Overall unadjusted survival was 65% at 3 years. Twelve deaths resulted from cardiovascular causes. A reversible defect on MPS was associated with a fatal cardiac event and all-cause mortality. The unadjusted hazard ratio of cardiac event with reversible defect on MPS was 3.1 (95% confidence interval, 1.1 to 18.2) and hazard ratio of death with reversible defect on MPS was 1.92 (95% confidence interval, 1.1 to 4.4). Thus, MPS may be a useful tool in cardiac risk stratification and in selecting patients with a favorable outcome after renal transplantation. Our patients with a reversible defect in particular have increased cardiac mortality. This group may benefit from coronary angiography.

  19. Anaesthesia ventilators

    Directory of Open Access Journals (Sweden)

    Rajnish K Jain

    2013-01-01

    Full Text Available Anaesthesia ventilators are an integral part of all modern anaesthesia workstations. Automatic ventilators in the operating rooms, which were very simple with few modes of ventilation when introduced, have become very sophisticated with many advanced ventilation modes. Several systems of classification of anaesthesia ventilators exist based upon various parameters. Modern anaesthesia ventilators have either a double circuit, bellow design or a single circuit piston configuration. In the bellows ventilators, ascending bellows design is safer than descending bellows. Piston ventilators have the advantage of delivering accurate tidal volume. They work with electricity as their driving force and do not require a driving gas. To enable improved patient safety, several modifications were done in circle system with the different types of anaesthesia ventilators. Fresh gas decoupling is a modification done in piston ventilators and in descending bellows ventilator to reduce th incidence of ventilator induced volutrauma. In addition to the conventional volume control mode, modern anaesthesia ventilators also provide newer modes of ventilation such as synchronised intermittent mandatory ventilation, pressure-control ventilation and pressure-support ventilation (PSV. PSV mode is particularly useful for patients maintained on spontaneous respiration with laryngeal mask airway. Along with the innumerable benefits provided by these machines, there are various inherent hazards associated with the use of the ventilators in the operating room. To use these workstations safely, it is important for every Anaesthesiologist to have a basic understanding of the mechanics of these ventilators and breathing circuits.

  20. Anaesthesia ventilators.

    Science.gov (United States)

    Jain, Rajnish K; Swaminathan, Srinivasan

    2013-09-01

    Anaesthesia ventilators are an integral part of all modern anaesthesia workstations. Automatic ventilators in the operating rooms, which were very simple with few modes of ventilation when introduced, have become very sophisticated with many advanced ventilation modes. Several systems of classification of anaesthesia ventilators exist based upon various parameters. Modern anaesthesia ventilators have either a double circuit, bellow design or a single circuit piston configuration. In the bellows ventilators, ascending bellows design is safer than descending bellows. Piston ventilators have the advantage of delivering accurate tidal volume. They work with electricity as their driving force and do not require a driving gas. To enable improved patient safety, several modifications were done in circle system with the different types of anaesthesia ventilators. Fresh gas decoupling is a modification done in piston ventilators and in descending bellows ventilator to reduce th incidence of ventilator induced volutrauma. In addition to the conventional volume control mode, modern anaesthesia ventilators also provide newer modes of ventilation such as synchronised intermittent mandatory ventilation, pressure-control ventilation and pressure-support ventilation (PSV). PSV mode is particularly useful for patients maintained on spontaneous respiration with laryngeal mask airway. Along with the innumerable benefits provided by these machines, there are various inherent hazards associated with the use of the ventilators in the operating room. To use these workstations safely, it is important for every Anaesthesiologist to have a basic understanding of the mechanics of these ventilators and breathing circuits.

  1. Anaesthesia ventilators

    Science.gov (United States)

    Jain, Rajnish K; Swaminathan, Srinivasan

    2013-01-01

    Anaesthesia ventilators are an integral part of all modern anaesthesia workstations. Automatic ventilators in the operating rooms, which were very simple with few modes of ventilation when introduced, have become very sophisticated with many advanced ventilation modes. Several systems of classification of anaesthesia ventilators exist based upon various parameters. Modern anaesthesia ventilators have either a double circuit, bellow design or a single circuit piston configuration. In the bellows ventilators, ascending bellows design is safer than descending bellows. Piston ventilators have the advantage of delivering accurate tidal volume. They work with electricity as their driving force and do not require a driving gas. To enable improved patient safety, several modifications were done in circle system with the different types of anaesthesia ventilators. Fresh gas decoupling is a modification done in piston ventilators and in descending bellows ventilator to reduce th incidence of ventilator induced volutrauma. In addition to the conventional volume control mode, modern anaesthesia ventilators also provide newer modes of ventilation such as synchronised intermittent mandatory ventilation, pressure-control ventilation and pressure-support ventilation (PSV). PSV mode is particularly useful for patients maintained on spontaneous respiration with laryngeal mask airway. Along with the innumerable benefits provided by these machines, there are various inherent hazards associated with the use of the ventilators in the operating room. To use these workstations safely, it is important for every Anaesthesiologist to have a basic understanding of the mechanics of these ventilators and breathing circuits. PMID:24249886

  2. The effect of captopril on thallium 201 myocardial perfusion in systemic sclerosis

    International Nuclear Information System (INIS)

    Kahan, A.; Devaux, J.Y.; Amor, B.; Menkes, C.J.; Weber, S.; Venot, A.; Strauch, G.

    1990-01-01

    In systemic sclerosis, abnormalities of myocardial perfusion are common and may be caused by a disturbance of the coronary microcirculation. We evaluated the long-term effect of captopril (75 to 150 mg per day) on thallium 201 myocardial perfusion in 12 normotensive patients with systemic sclerosis. Captopril significantly decreased the mean (+/- SD) number of segments with thallium 201 myocardial perfusion defects (6.5 +/- 1.9 at baseline and 4.4 +/- 2.7 after 1 year of treatment with captopril; p less than 0.02) and increased the mean global thallium score (9.6 +/- 1.7 at baseline and 11.4 +/- 2.1 after captopril; p less than 0.05). In a control group of eight normotensive patients with systemic sclerosis who did not receive captopril, no significant modification in thallium results occurred. Side effects with captopril included hypotension (six patients), taste disturbances (one patient), and skin rash (one patient). These side effects subsided when the dosage was reduced. These findings demonstrate that captopril improves thallium 201 myocardial perfusion in patients with systemic sclerosis and may therefore have a beneficial effect on scleroderma myocardial disease

  3. Histogram based analysis of lung perfusion of children after congenital diaphragmatic hernia repair.

    Science.gov (United States)

    Kassner, Nora; Weis, Meike; Zahn, Katrin; Schaible, Thomas; Schoenberg, Stefan O; Schad, Lothar R; Zöllner, Frank G

    2018-05-01

    To investigate a histogram based approach to characterize the distribution of perfusion in the whole left and right lung by descriptive statistics and to show how histograms could be used to visually explore perfusion defects in two year old children after Congenital Diaphragmatic Hernia (CDH) repair. 28 children (age of 24.2±1.7months; all left sided hernia; 9 after extracorporeal membrane oxygenation therapy) underwent quantitative DCE-MRI of the lung. Segmentations of left and right lung were manually drawn to mask the calculated pulmonary blood flow maps and then to derive histograms for each lung side. Individual and group wise analysis of histograms of left and right lung was performed. Ipsilateral and contralateral lung show significant difference in shape and descriptive statistics derived from the histogram (Wilcoxon signed-rank test, phistogram derived parameters. Histogram analysis can be a valuable tool to characterize and visualize whole lung perfusion of children after CDH repair. It allows for several possibilities to analyze the data, either describing the perfusion differences between the right and left lung but also to explore and visualize localized perfusion patterns in the 3D lung volume. Subgroup analysis will be possible given sufficient sample sizes. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. POSTEROLATERAL DEFECT OF THE NORMAL HUMAN HEART INVESTIGATED WITH NITROGEN-13-AMMONIA AND DYNAMIC PET

    NARCIS (Netherlands)

    DEJONG, RM; BLANKSMA, PK; WILLEMSEN, ATM; ANTHONIO, RL; MEEDER, JG; PRUIM, J; VAALBURG, W; LIE, KI

    The posterolateral defect is a common artifact seen when static N-13-ammonia imaging with PET is used to assess myocardial perfusion. The aim of this study was to compare dynamic and static N-13-ammonia PET and to obtain more insight into the cause of the posterolateral defect. Methods: Dynamic

  5. Chromosome evaluation of Angus calves with unilateral congenital cleft lip and jaw (cheilognathoschisis).

    Science.gov (United States)

    Swartz, H A; Vogt, D W; Kintner, L D

    1982-04-01

    Two purebred Angus calves with unilateral cleft lip and jaw were karyotyped and anatomically described. Both calves, 1 male and 1 female, were from the same farm and were born in March and April 1980. The defect was most pronounced in the female calf. Both calves exhibited an elevated midline of the hard palate. The female calf also manifested characteristics indicative of proportionate dwarfism. Karyotypes were constructed after a 72-hour culture of peripheral blood. The 2N number was 60 with no apparent chromosome abnormality. The coefficient of relationship between the 2 affected calves was calculated to be 0.78%. The cause of the defect could not be ascertained from the limited data available.

  6. Quantitative myocardial perfusion PET parametric imaging at the voxel-level

    International Nuclear Information System (INIS)

    Mohy-ud-Din, Hassan; Rahmim, Arman; Lodge, Martin A

    2015-01-01

    Quantitative myocardial perfusion (MP) PET has the potential to enhance detection of early stages of atherosclerosis or microvascular dysfunction, characterization of flow-limiting effects of coronary artery disease (CAD), and identification of balanced reduction of flow due to multivessel stenosis. We aim to enable quantitative MP-PET at the individual voxel level, which has the potential to allow enhanced visualization and quantification of myocardial blood flow (MBF) and flow reserve (MFR) as computed from uptake parametric images. This framework is especially challenging for the 82 Rb radiotracer. The short half-life enables fast serial imaging and high patient throughput; yet, the acquired dynamic PET images suffer from high noise-levels introducing large variability in uptake parametric images and, therefore, in the estimates of MBF and MFR. Robust estimation requires substantial post-smoothing of noisy data, degrading valuable functional information of physiological and pathological importance. We present a feasible and robust approach to generate parametric images at the voxel-level that substantially reduces noise without significant loss of spatial resolution. The proposed methodology, denoted physiological clustering, makes use of the functional similarity of voxels to penalize deviation of voxel kinetics from physiological partners. The results were validated using extensive simulations (with transmural and non-transmural perfusion defects) and clinical studies. Compared to post-smoothing, physiological clustering depicted enhanced quantitative noise versus bias performance as well as superior recovery of perfusion defects (as quantified by CNR) with minimal increase in bias. Overall, parametric images obtained from the proposed methodology were robust in the presence of high-noise levels as manifested in the voxel time-activity-curves. (paper)

  7. Quantitative Renal Cortical Perfusion in Human Subjects with Magnetic Resonance Imaging Using Iron-Oxide Nanoparticles: Influence of T1 Shortening

    Energy Technology Data Exchange (ETDEWEB)

    Morell, A.; Ahlstrom, H.; Schoenberg, S.O.; Abildgaard, A.; Bock, M.; Bjoernerud, A. (Dept. of Diagnostic Radiology, Uppsala Univ. Hospital, Uppsala (Sweden))

    2008-10-15

    Background: Using conventional contrast agents, the technique of quantitative perfusion by observing the transport of a bolus with magnetic resonance imaging (MRI) is limited to the brain due to extravascular leakage. Purpose: To perform quantitative perfusion measurements in humans with an intravascular contrast agent, and to estimate the influence of the T1 relaxivity of the contrast agent on the first-pass response. Material and Methods: Renal cortical perfusion was measured quantitatively in six patients with unilateral renal artery stenosis using a rapid gradient double-echo sequence in combination with an intravenous bolus injection of NC100150 Injection, an intravascular contrast agent based on iron-oxide nanoparticles. The influence of T1 relaxivity was measured by comparing perfusion results based on single- and double-echo data. Results: The mean values of cortical blood flow, cortical blood volume, and mean transit time in the normal kidneys were measured to 339+-60 ml/min/100 g, 41+-8 ml/100 g, and 7.3+-1.0 s, respectively, based on double-echo data. The corresponding results based on single-echo data, which are not compensated for the T1 relaxivity, were 254+-47 ml/min/100 g, 27+-3 ml/100 g, and 6+-1.2 s, respectively. Conclusion: The use of a double-echo sequence enabled elimination of confounding T1 effects and consequent systematic underestimation of the perfusion.

  8. Role of myocardial perfusion scintigraphy post invasive coronary angiography in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Harisankar, C.N.B.; Mittal, Bhagwant Rai; Kamaleshwaran, K.K.; Bhattacharya, Anish; Singh, Baljinder; Mahajan, Rajiv

    2010-01-01

    The presence of severe hypokinesia or akinesia and near complete stenotic lesions on coronary angiography, in a patient with acute myocardial infarction raises a question of viability in the involved territory and its response to revascularization. The decision of revascularization can be effectively taken after myocardial perfusion scintigraphy (MPS). Aim: To evaluate the role of MPS in patients with acute or recent myocardial infarction after invasive coronary angiography. Materials and Methods: Thirty-five patients (27 Males, 8 Females; Mean age 54 years) with acute myocardial infarction, who underwent invasive angiography, were included prospectively. Invasive angiography was attempted during the episode of acute chest pain in 20 patients. Fifteen patients underwent angiography without MPS because of non-availability of MPS at the time of initial presentation in the referring hospital. Revascularization was deferred because of complete/near complete block of artery with hypokinesia/akinesia of the distal LV segments in 32/35 patients and 50 to 70% block in 3/35. These patients were subjected to MPS. Results: Twenty patients underwent stress MPS and 15 underwent nitrate-augmented rest re-distribution study (RR study). Imaging was performed using the hybrid SPECT/CT system. The average defect size of the perfusion defect was 34% (5 - 57% range). Sixteen patients (46%) had fixed perfusion defects. Reversible ischemia was present in 19 (54%). Ten patients had a 10% of the LV myocardium, and underwent the invasive revascularization procedure. Conclusion: MPS is invaluable in patients who have total/near total occlusion of the coronary artery and distal segment hypokinesia or akinesia on invasive angiography. One in four patients, deemed to have non-viable myocardium, underwent an invasive revascularization after undergoing MPS. (author)

  9. Evaluation of ventilators for mouthpiece ventilation in neuromuscular disease.

    Science.gov (United States)

    Khirani, Sonia; Ramirez, Adriana; Delord, Vincent; Leroux, Karl; Lofaso, Frédéric; Hautot, Solène; Toussaint, Michel; Orlikowski, David; Louis, Bruno; Fauroux, Brigitte

    2014-09-01

    Daytime mouthpiece ventilation is a useful adjunct to nocturnal noninvasive ventilation (NIV) in patients with neuromuscular disease. The aims of the study were to analyze the practice of mouthpiece ventilation and to evaluate the performance of ventilators for mouthpiece ventilation. Practice of mouthpiece ventilation was assessed by a questionnaire, and the performance of 6 home ventilators with mouthpiece ventilation was assessed in a bench test using 24 different conditions per ventilator: 3 mouthpieces, a child and an adult patient profile, and 4 ventilatory modes. Questionnaires were obtained from 30 subjects (mean age 33 ± 11 y) using NIV for 12 ± 7 y. Fifteen subjects used NIV for > 20 h/day, and 11 were totally ventilator-dependent. The subject-reported benefits of mouthpiece ventilation were a reduction in dyspnea (73%) and fatigue (93%) and an improvement in speech (43%) and eating (27%). The bench study showed that none of the ventilators, even those with mouthpiece ventilation software, were able to deliver mouthpiece ventilation without alarms and/or autotriggering in each condition. Alarms and/or ineffective triggering or autotriggering were observed in 135 of the 198 conditions. The occurrence of alarms was more common with a large mouthpiece without a filter compared to a small mouthpiece with a filter (P ventilator. Subjects are satisfied with mouthpiece ventilation. Alarms are common with home ventilators, although less common in those with mouthpiece ventilation software. Improvements in home ventilators are needed to facilitate the expansion of mouthpiece ventilation. Copyright © 2014 by Daedalus Enterprises.

  10. Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, Patricia M., E-mail: investigacion@diagnosticomaipu.com.ar; Deviggiano, Alejandro; Capunay, Carlos; Campisi, Roxana; López Munain, Marina de; Vallejos, Javier; Tajer, Carlos; Rodriguez-Granillo, Gaston A.

    2015-04-15

    Highlights: •We evaluated myocardial perfusion by dual energy computed tomography (DECT). •We included patients with intermediate to high likelihood of coronary artery disease. •Stress myocardial perfusion by DECT had a reliable accuracy for the detection of ischemia. •Stress myocardial perfusion with DECT showed an incremental value over anatomical evaluation. •DECT imaging was associated to a significant reduction in radiation dose compared to SPECT. -- Abstract: Purpose: We sought to explore the diagnostic performance of dual energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD). Materials and methods: Consecutive patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT) constituted the study population and were scanned using a DECT scanner equipped with gemstone detectors for spectral imaging, and a SPECT. The same pharmacological stress was used for both scans. Results: Twenty-five patients were prospectively included in the study protocol. The mean age was 63.4 ± 10.6 years. The total mean effective radiation dose was 7.5 ± 1.2 mSv with DECT and 8.2 ± 1.7 mSv with SPECT (p = 0.007). A total of 425 left ventricular segments were evaluated by DECT, showing a reliable accuracy for the detection of reversible perfusion defects [area under ROC curve (AUC) 0.84 (0.80–0.87)]. Furthermore, adding stress myocardial perfusion provided a significant incremental value over anatomical evaluation alone by computed tomography coronary angiography [AUC 0.70 (0.65–0.74), p = 0.003]. Conclusions: In this pilot investigation, stress myocardial perfusion by DECT demonstrated a significant incremental value over anatomical evaluation alone by CTCA for the detection of reversible perfusion defects.

  11. Association between unilateral or bilateral mastectomy and breast cancer death in patients with unilateral ductal carcinoma.

    Science.gov (United States)

    Agarwal, Shailesh; Pappas, Lisa; Agarwal, Jayant

    2017-01-01

    Utilization of bilateral mastectomy for unilateral breast cancer is increasing despite cost and surgical risks with conflicting reports of survival benefit. Current studies evaluating death after bilateral mastectomy have included patients treated both with breast conservation therapy and unilateral mastectomy. In this study, we directly compared breast cancer-specific death of patients who underwent bilateral or unilateral mastectomy for unilateral breast cancer using a matched cohort analysis. This was an observational study of women diagnosed with unilateral breast cancer from 1998 through 2002, using the Surveillance, Epidemiology, and End Results (SEER) database. A 4-to-1 matched cohort of patients was selected including 14,075 patients. Mortality of the groups was compared using Cox proportional hazards models for cause-specific death. A total of 41,510 patients diagnosed with unilateral breast cancer were included. Unilateral mastectomy was performed in 93% of patients, while bilateral mastectomy was performed in the remaining 7% of patients. When 4-to-1 matching was performed, 11,260 unilateral mastectomy and 2,815 bilateral mastectomy patients were included. Patients with bilateral mastectomy did not have a significantly lower hazard of breast cancer-specific death when compared with patients with unilateral mastectomy (hazard ratio: 0.92 vs 1.00, p =0.11). Bilateral mastectomy did not provide a clinically or statistically significant breast cancer-specific mortality benefit over unilateral mastectomy based on a matched cohort analysis of a nationwide population database. These findings should be interpreted in the context of patient preference and alternative benefits of bilateral mastectomy.

  12. Xenon ventilation CT using dual-source and dual-energy technique in children with bronchiolitis obliterans: correlation of xenon and CT density values with pulmonary function test results

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Yang, Dong Hyun; Seo, Joon Beom; Chae, Eun Jin; Lee, Jeongjin; Hong, Soo-Jong; Yu, Jinho; Kim, Byoung-Ju; Krauss, Bernhard

    2010-01-01

    Xenon ventilation CT using dual-source and dual-energy technique is a recently introduced, promising functional lung imaging method. To expand its clinical applications evidence of additional diagnostic value of xenon ventilation CT over conventional chest CT is required. To evaluate the usefulness of xenon ventilation CT using dual-source and dual-energy technique in children with bronchiolitis obliterans (BO). Seventeen children (age 7-18 years; 11 boys) with BO underwent xenon ventilation CT using dual-source and dual-energy technique. Xenon and CT density values were measured in normal and hyperlucent lung regions on CT and were compared between the two regions. Volumes of hyperlucent regions and ventilation defects were calculated with thresholds determined by visual and histogram-based analysis. Indexed volumes of hyperlucent lung regions and ventilation defects were correlated with pulmonary function test results. Effective doses of xenon CT were calculated. Xenon (14.6 ± 6.4 HU vs 26.1 ± 6.5 HU; P 25-75 , (γ = -0.68-0.88, P ≤ 0.002). Volume percentages of xenon ventilation defects (35.0 ± 16.4%)] were not significantly different from those of hyperlucent lung regions (38.2 ± 18.6%). However, mismatches between the volume percentages were variable up to 21.4-33.3%. Mean effective dose of xenon CT was 1.9 ± 0.5 mSv. In addition to high-resolution anatomic information, xenon ventilation CT using dual-source and dual-energy technique demonstrates impaired regional ventilation and its heterogeneity accurately in children with BO without additional radiation exposure. (orig.)

  13. Selective cerebro-myocardial perfusion in complex congenital aortic arch pathology: a novel technique.

    Science.gov (United States)

    De Rita, Fabrizio; Lucchese, Gianluca; Barozzi, Luca; Menon, Tiziano; Faggian, Giuseppe; Mazzucco, Alessandro; Luciani, Giovanni Battista

    2011-11-01

    Simultaneous cerebro-myocardial perfusion has been described in neonatal and infant arch surgery, suggesting a reduction in cardiac morbidity. Here reported is a novel technique for selective cerebral perfusion combined with controlled and independent myocardial perfusion during surgery for complex or recurrent aortic arch lesions. From April 2008 to April 2011, 10 patients with arch pathology underwent surgery (two hypoplastic left heart syndrome [HLHS], four recurrent arch obstruction, two aortic arch hypoplasia + ventricular septal defect [VSD], one single ventricle + transposition of the great arteries + arch hypoplasia, one interrupted aortic arch type B + VSD). Median age was 63 days (6 days-36 years) and median weight 4.0 kg (1.6-52). Via midline sternotomy, an arterial cannula (6 or 8 Fr for infants) was directly inserted into the innominate artery or through a polytetrafluoroethylene (PTFE) graft (for neonates cerebro-myocardial perfusion was 39 ± 18 min (17-69). Weaning from cardiopulmonary bypass was achieved without inotropic support in three and with low dose in seven patients. One patient required veno-arterial extracorporeal membrane oxygenation. Four patients, body weight cerebro-myocardial perfusion is feasible in patients with complex or recurrent aortic arch disease, starting from premature newborn less than 2.0 kg of body weight to adults. The technique is as safe as previously reported methods of cerebro-myocardial perfusion and possibly more versatile. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  14. Subtle Cardiovascular Dysfunction in the Unilateral 6-Hydroxydopamine-Lesioned Rat

    Directory of Open Access Journals (Sweden)

    K. Slack

    2010-01-01

    Full Text Available The present study evaluated whether the unilateral 6-hydroxydopamine (6-OHDA model of Parkinson's disease produces autonomic deficits. Autonomic parameters were assessed by implanting a small radiofrequency telemetry device which measured heart rate variability (HRV, diurnal rhythms of heart rate (HR, core body temperature (cBT and locomotor activity (LA. Rats then received 6-OHDA lesion or sham surgery. 6-OHDA lesioned rats exhibited head and body axis biases, defective sensorimotor function (“disengage” test, and prominent apomorphine rotation (all P<.05 versus controls. Diurnal rhythm of HR was lower for 6-OHDA lesioned rats (n=8 versus controls (n=6; P<.05. Whilst HR decreased similarly in both groups during the day, there was a greater decrease in HR for the 6-OHDA lesioned rats at night (by 38 b.p.m. relative to 17 b.p.m. for controls. LA and cBT did not differ between surgery groups. This study indicates the unilateral 6-OHDA model of PD shows subtle signs of cardiovascular autonomic dysfunction.

  15. Low-dose dobutamine stress gated SPET for identification of viable myocardium: comparison with stress-rest perfusion SPET and PET

    International Nuclear Information System (INIS)

    Yoshinaga, Keiichiro; Tamaki, Nagara; Katoh, Chietsugu; Kuge, Yuji; Noriyasu, Kazuyuki; Yamada, Satoshi; Ito, Yoshinori; Kohya, Tetsuro; Kitabatake, Akira; Kawai, Yuko

    2002-01-01

    The detection of viable myocardium is important for the prediction of functional recovery after revascularisation. However, a fixed perfusion defect often includes viable myocardium, and perfusion imaging then underestimates myocardial viability. We previously reported that low-dose dobutamine stress gated single-photon emission tomography (SPET) provides similar findings to dobutamine stress echocardiography in the assessment of myocardial viability. The present study investigated whether low-dose dobutamine stress gated SPET is of additional value as compared with stress-rest technetium-99m tetrofosmin SPET for the detection of myocardial viability. Standard stress-rest perfusion SPET, low-dose dobutamine stress gated SPET and fluorine-18 fluorodeoxyglucose positron emission tomography (FDG PET) were studied in 23 patients (mean age 67±7.6 years) with previous myocardial infarction. Twenty-one of them were successfully studied with each technique. FDG PET viability (FDG uptake ≥50%) was employed as the gold standard. One-day stress-rest 99m Tc-tetrofosmin myocardial SPET was performed. After the resting study, gated SPET was acquired following infusion of 7.5 μg kg -1 min -1 of dobutamine. Left ventricular wall motion in 16 segments was assessed by cine mode display using a four-point scale. Myocardial viability was considered present when there was improvement by one point. Of a total of 336 segments analysed, 53 had persistent defects on stress-rest perfusion SPET. FDG viability was seen in 16 of 17 dobutamine-responsive segments, but in only 11 of 36 dobutamine non-responsive segments (P<0.01). Thus, in the segments with persistent defects, viability findings on low-dose dobutamine stress gated SPET were concordant with those on FDG PET in 77% of segments (kappa value =0.55). For the detection of FDG-viable myocardium, the combination of stress-rest perfusion SPET and low-dose dobutamine stress gated SPET achieved a better sensitivity than stress

  16. Unilateral initiatives

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This paper reports on arms control which is generally thought of in terms of formal negotiations with an opponent, with the resulting agreements embodied in a treaty. This is not surprising, since arms control discussions between opponents are both important and politically visible. There are, however, strong reasons for countries to consider and frequently take unilateral initiatives. To do so is entirely consistent with the established major precepts of arms control which state that arms control is designed to reduce the risk of war, the costs of preparing for war, and the death and destruction if war should come. Unilateral initiatives on what weapons are purchased, which ones are eliminated and how forces are deployed can all relate to these objectives. There are two main categories of motives for unilateral initiatives in arms control. In one category, internal national objectives are the dominant, often sole, driving force; the initiative is undertaken for our own good

  17. Reproducibility of quantitative planar thallium-201 scintigraphy: quantitative criteria for reversibility of myocardial perfusion defects

    International Nuclear Information System (INIS)

    Sigal, S.L.; Soufer, R.; Fetterman, R.C.; Mattera, J.A.; Wackers, F.J.

    1991-01-01

    Fifty-two paired stress/delayed planar 201 TI studies (27 exercise studies, 25 dipyridamole studies) were processed twice by seven technologists to assess inter- and intraobserver variability. The reproducibility was inversely related to the size of 201 Tl perfusion abnormalities. Intraobserver variability was not different between exercise and dipyridamole studies for lesions of similar size. Based upon intraobserver variability, objective quantitative criteria for reversibility of perfusion abnormalities were defined. These objective criteria were tested prospectively in a separate group of 35 201 Tl studies and compared with the subjective interpretation of quantitative circumferential profiles. Overall, exact agreement existed in 78% of images (kappa statistic k = 0.66). We conclude that quantification of planar 201 Tl scans is highly reproducible, with acceptable inter- and intraobserver variability. Objective criteria for lesion reversibility correlated well with analysis by experienced observers

  18. Myocardial perfusion after prolonged submaximal exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Flotats, A.; Mena, E.; Camacho, V.; Tembl, A.; Hernandez, M.A.; Estorch, M.; Carrio, I.; Serra-Grima, R.

    2002-01-01

    Aim: Exercise training in patients with coronary artery disease (CAD) has established benefits. We assessed myocardial perfusion after submaximal but prolonged exercise in patients with CAD, who were enrolled in supervised exercise rehabilitation programs. Material and Methods: Nine patients with CAD enrolled in supervised exercise rehabilitation programs (7 men, 2 women; mean age 54±9 years), 7 with prior AMI and 2 with re-vascularized (CABG) multiple vessel disease, were encouraged to walk/run actively around the perimeter of our Hospital during the annual social sporting event organised in our Institution. Patients were studied by means of perfusion Tc-99m tetrofosmin SPECT imaging after prolonged exercise and at rest (gated SPECT), for two consecutive years. All patients remained symptom free during this interval period. Quantitative analysis was performed dividing polar map images in 13 segments. Tracer activity 9% in the resting image. The analysis was focused on those segments showing perfusion defects. Results: No symptoms other than fatigue were registered during prolonged exercise (range 1-2 hr). There were no significant differences in distance covered (7,462±3,031 m vs. 8,456±2,998 m), heart rate (92±11 bpm vs. 85±13 bpm) and rate-pressure product at the end of exercise (10,804±2,467 vs. 10,403±2,955) or gated SPECT calculated LVEF (44%±19 vs. 46%±20) between the two consecutive annual sporting events. Tracer activity in segments with perfusion defects did not significantly differ between both events. Overall agreement between both examinations regarding patient classification as having scar/ischemia was 77% (kappa=0.49). There was one patient who showed partial reversibility in three segments, consistent with mild anteroapical ischemia, only in the first examination. On the other hand, another patient showed reversibility in one segment (medium septum), only in the second examination, when he covered a distance 1.3 times superior. Conclusions

  19. Exhaled CO2 Parameters as a Tool to Assess Ventilation-Perfusion Mismatching during Neonatal Resuscitation in a Swine Model of Neonatal Asphyxia

    Science.gov (United States)

    Li, Elliott Shang-shun; Cheung, Po-Yin; O'Reilly, Megan; LaBossiere, Joseph; Lee, Tze-Fun; Cowan, Shaun; Bigam, David L.; Schmölzer, Georg Marcus

    2016-01-01

    Background End-tidal CO2 (ETCO2), partial pressure of exhaled CO2 (PECO2), and volume of expired CO2 (VCO2) can be continuously monitored non-invasively to reflect pulmonary ventilation and perfusion status. Although ETCO2 ≥14mmHg has been shown to be associated with return of an adequate heart rate in neonatal resuscitation and quantifying the PECO2 has the potential to serve as an indicator of resuscitation quality, there is little information regarding capnometric measurement of PECO2 and ETCO2 in detecting return of spontaneous circulation (ROSC) and survivability in asphyxiated neonates receiving cardiopulmonary resuscitation (CPR). Methods Seventeen newborn piglets were anesthetized, intubated, instrumented, and exposed to 45-minute normocapnic hypoxia followed by apnea to induce asphyxia. Protocolized resuscitation was initiated when heart rate decreased to 25% of baseline. Respiratory and hemodynamic parameters including ETCO2, PECO2, VCO2, heart rate, cardiac output, and carotid artery flow were continuously measured and analyzed. Results There were no differences in respiratory and hemodynamic parameters between surviving and non-surviving piglets prior to CPR. Surviving piglets had significantly higher ETCO2, PECO2, VCO2, cardiac index, and carotid artery flow values during CPR compared to non-surviving piglets. Conclusion Surviving piglets had significantly better respiratory and hemodynamic parameters during resuscitation compared to non-surviving piglets. In addition to optimizing resuscitation efforts, capnometry can assist by predicting outcomes of newborns requiring chest compressions. PMID:26766424

  20. Exhaled CO2 Parameters as a Tool to Assess Ventilation-Perfusion Mismatching during Neonatal Resuscitation in a Swine Model of Neonatal Asphyxia.

    Directory of Open Access Journals (Sweden)

    Elliott Shang-shun Li

    Full Text Available End-tidal CO2 (ETCO2, partial pressure of exhaled CO2 (PECO2, and volume of expired CO2 (VCO2 can be continuously monitored non-invasively to reflect pulmonary ventilation and perfusion status. Although ETCO2 ≥14 mmHg has been shown to be associated with return of an adequate heart rate in neonatal resuscitation and quantifying the PECO2 has the potential to serve as an indicator of resuscitation quality, there is little information regarding capnometric measurement of PECO2 and ETCO2 in detecting return of spontaneous circulation (ROSC and survivability in asphyxiated neonates receiving cardiopulmonary resuscitation (CPR.Seventeen newborn piglets were anesthetized, intubated, instrumented, and exposed to 45-minute normocapnic hypoxia followed by apnea to induce asphyxia. Protocolized resuscitation was initiated when heart rate decreased to 25% of baseline. Respiratory and hemodynamic parameters including ETCO2, PECO2, VCO2, heart rate, cardiac output, and carotid artery flow were continuously measured and analyzed.There were no differences in respiratory and hemodynamic parameters between surviving and non-surviving piglets prior to CPR. Surviving piglets had significantly higher ETCO2, PECO2, VCO2, cardiac index, and carotid artery flow values during CPR compared to non-surviving piglets.Surviving piglets had significantly better respiratory and hemodynamic parameters during resuscitation compared to non-surviving piglets. In addition to optimizing resuscitation efforts, capnometry can assist by predicting outcomes of newborns requiring chest compressions.

  1. GAMMAGRAFÍA DE PERFUSIÓN MIOCÁRDICA EN MUJERES POSMENOPÁUSICAS CON ANGINA Y CORONARIAS EPICÁRDICAS ANGIOGRÁFICAMENTE NORMALES / Myocardial perfusion scintigraphy in postmenopausal women with angina and angiographically normal epicardial coronary

    Directory of Open Access Journals (Sweden)

    Sherien Sixto Fernández

    2011-03-01

    Full Text Available Introduction and Objectives: Microvascular angina is common in postmenopausal women. Myocardial ischemia was induced by stress testing, and reports have been published about the relationship between endothelial dysfunction and myocardial perfusion. The objective of this research was to determine whether myocardial ischemia can be evidenced by abnormalities in perfusion and function, as detected by myocardial scintigraphy in women with typical angina, normal coronary angiography and endothelial dysfunction. Methods: 59 women underwent lipid and endothelial function measurements by brachial artery ultrasound, in addition, a 24-hour ECG study (Holter. During the scintigraphy a stress-rest protocol was applied. Patients were divided into two groups according to presence (group I or absence (group II of myocardial perfusion defects. Results: 21 patients showed perfusion defects. 57 % of group I exhibited greater endothelial dysfunction. Only twelve patients showed reversible perfusion defects, and 75 % of the cases was associated with a reduction of post-stress left ventricular ejection fraction, greater than 5 %, and regional abnormalities of wall motion. Three patients in group I showed evidence of ischemia compared with four in Group II. Conclusions: The stress-induced ischemia was associated with a reduced post-stress ejection fraction and endothelial dysfunction in the studied women, and no ischemic changes in the Holter were found.

  2. Bench performance of ventilators during simulated paediatric ventilation.

    Science.gov (United States)

    Park, M A J; Freebairn, R C; Gomersall, C D

    2013-05-01

    This study compares the accuracy and capabilities of various ventilators using a paediatric acute respiratory distress syndrome lung model. Various compliance settings and respiratory rate settings were used. The study was done in three parts: tidal volume and FiO2 accuracy; pressure control accuracy and positive end-expiratory pressure (PEEP) accuracy. The parameters set on the ventilator were compared with either or both of the measured parameters by the test lung and the ventilator. The results revealed that none of the ventilators could consistently deliver tidal volumes within 1 ml/kg of the set tidal volume, and the discrepancy between the delivered volume and the volume measured by the ventilator varied greatly. The target tidal volume was 8 ml/kg, but delivered tidal volumes ranged from 3.6-11.4 ml/kg and the volumes measured by the ventilator ranged from 4.1-20.6 ml/kg. All the ventilators maintained pressure within 20% of the set pressure, except one ventilator which delivered pressures of up to 27% higher than the set pressure. Two ventilators maintained PEEP within 10% of the prescribed PEEP. The majority of the readings were also within 10%. However, three ventilators delivered, at times, PEEPs over 20% higher. In conclusion, as lung compliance decreases, especially in paediatric patients, some ventilators perform better than others. This study highlights situations where ventilators may not be able to deliver, nor adequately measure, set tidal volumes, pressure, PEEP or FiO2.

  3. Pulmonary function-morphologic relationships assessed by SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2012-01-01

    Pulmonary single photon emission computed tomography-computed tomography (SPECT-CT) fusion images provide objective and comprehensive assessment of pulmonary function and morphology relationships at cross-sectional lungs. This article reviewed the noteworthy findings of lung pathophysiology in wide-spectral lung disorders, which have been revealed on SPECT-CT fusion images in 8 years of experience. The fusion images confirmed the fundamental pathophysiologic appearance of lung low CT attenuation caused by airway obstruction-induced hypoxic vasoconstriction and that caused by direct pulmonary arterial obstruction as in acute pulmonary thromboembolism (PTE). The fusion images showed better correlation of lung perfusion distribution with lung CT attenuation changes at lung mosaic CT attenuation (MCA) compared with regional ventilation in the wide-spectral lung disorders, indicating that lung heterogeneous perfusion distribution may be a dominant mechanism of MCA on CT. SPECT-CT angiography fusion images revealed occasional dissociation between lung perfusion defects and intravascular clots in acute PTE, indicating the importance of assessment of actual effect of intravascular colts on peripheral lung perfusion. Perfusion SPECT-CT fusion images revealed the characteristic and preferential location of pulmonary infarction in acute PTE. The fusion images showed occasional unexpected perfusion defects in normal lung areas on CT in chronic obstructive pulmonary diseases and interstitial lung diseases, indicating the ability of perfusion SPECT superior to CT for detection of mild lesions in these disorders. The fusion images showed frequent ''steal phenomenon''-induced perfusion defects extending to the surrounding normal lung of arteriovenous fistulas and those at normal lungs on CT in hepatopulmonary syndrome. Comprehensive assessment of lung function-CT morphology on fusion images will lead to more profound understanding of lung pathophysiology in wide-spectral lung

  4. Value of myocardial perfusion SPECT in pediatric population

    International Nuclear Information System (INIS)

    Massardo, T.; Coll, C.; Prat, H.; Gonzalez, P.; Doggenweiller, P.; Castillo, M.E.; Solis, A.

    2002-01-01

    Isotopic myocardial perfusion studies are less frequently used in children than in adults and their indications are also different. Our goal was to analyze retrospectively the experience with stress perfusion myocardial SPECT in pediatric population. Method: Since 1998 to 2001, ten studies were performed to 5 girls and 3 boys. Their mean age was 7±3 years ranging from 1-11. Three of them presented abnormal coronary arteries pre and post surgical intervention with or without coil; three had Kawasaki disease with coronary aneurysms and the other two, congenital cardiopathies (Cantrell pentalogy and great vessel transposition,both with posterior left ventricular hypokinesia post surgery). Stress was obtained using dipyridamole infusion (0.56 mg/kg) in 6 cases and treadmill exercise using Bruce protocol in 4. All those tests were well tolerated. Sestamibi Tc99m was selected in 80% of the cases and Tl 201 in the rest. Only 2 small children required anesthesia during SPECT acquisition. Results: Stress EKG did not demonstrated ischemia in any case. Coronary angiography was performed only in 50% of the patients, it was concordant with SPECT features in all, two of those patients presented transient perfusion defects (one Kawasaki and one abnormal coronary artery with a fistulae).The repaired pentalogy presented ischemia and septal infarction; in that patient echocardiographic hipokinesia was concordant with fixed hypoperfusion. One case with abnormal coronary plus mitral regurgitation (without isotopic ischemia) was submitted to embolization posteriorly, obtaining motion improvement. Clinical outcome was concordant with the presence or absence of isotopic ischemia in the rest of the patients. Conclusion: SPECT myocardial perfusion was helpful in the therapeutic approach and in prediction of outcome in children

  5. Anaesthesia ventilators

    OpenAIRE

    Jain, Rajnish K; Swaminathan, Srinivasan

    2013-01-01

    Anaesthesia ventilators are an integral part of all modern anaesthesia workstations. Automatic ventilators in the operating rooms, which were very simple with few modes of ventilation when introduced, have become very sophisticated with many advanced ventilation modes. Several systems of classification of anaesthesia ventilators exist based upon various parameters. Modern anaesthesia ventilators have either a double circuit, bellow design or a single circuit piston configuration. In the bello...

  6. [Anesthesia ventilators].

    Science.gov (United States)

    Otteni, J C; Beydon, L; Cazalaà, J B; Feiss, P; Nivoche, Y

    1997-01-01

    To review anaesthesia ventilators in current use in France by categories of ventilators. References were obtained from computerized bibliographic search. (Medline), recent review articles, the library of the service and personal files. Anaesthesia ventilators can be allocated into three groups, depending on whether they readminister expired gases or not or allow both modalities. Contemporary ventilators provide either constant volume ventilation, or constant pressure ventilation, with or without a pressure plateau. Ventilators readministering expired gases after CO2 absorption, or closed circuit ventilators, are either of a double- or a single-circuit design. Double-circuit ventilators, or pneumatical bag or bellows squeezers, or bag-in-bottle or bellows-in-bottle (or box) ventilators, consist of a primary, or driving circuit (bottle or box) and a secondary or patient circuit (including a bag or a bellows or membrane chambers). Bellows-in-bottle ventilators have either standing bellows ascending at expiration, or hanging bellows, descending at expiration. Ascending bellows require a positive pressure of about 2 cmH2O throughout exhalation to allow the bellows to refill. The expired gas volume is a valuable indicator for leak and disconnection. Descending bellows generate a slight negative pressure during exhalation. In case of leak or disconnection they aspirate ambient air and cannot act therefore as an indicator for integrity of the circuit and the patient connection. Closed circuit ventilators with a single-circuit (patient circuit) include a insufflating device consisting either in a bellows or a cylinder with a piston, operated by a electric or pneumatic motor. As the hanging bellows of the double circuit ventilators, they generate a slight negative pressure during exhalation and aspirate ambient air in case of leak or disconnection. Ventilators not designed for the readministration of expired gases, or open circuit ventilators, are generally stand

  7. Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson

    International Nuclear Information System (INIS)

    Noel, Cory V.; Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh; Moffett, Brady

    2017-01-01

    Dipyridamole and adenosine are traditional pharmacological stressors for myocardial perfusion. Regadenoson, a selective adenosine A2A agonist, has a lower side effect profile with lower incidence of bronchospasm and bradycardia. There is a growing need for myocardial perfusion assessment within pediatrics. There is no report on the utility of regadenoson as a stress agent in children. To observe the safety and feasibility of regadenoson as a pharmacologic stressor for perfusion cardiac MR in a pilot cohort of pediatric patients weighing more than 40 kg who have congenital heart disease and pediatric acquired heart disease. We reviewed our initial experience with regadenoson stress cardiac MR in 31 pediatric patients 15.8 ± 1.7 years (range 12-22 years) with congenital heart disease and acquired heart disease. Mean patient weight was 60 ± 15 kg (range of 40-93 kg). All patients underwent cardiac MR because of concern for ischemia. The cohort included a heterogeneous group of patients at a pediatric institution with potential risk for ischemia. Subjects' heart rate and blood pressure were monitored and pharmacologic stress was induced by injection of 400 mcg of regadenoson. We evaluated their hemodynamic response and adverse effects using changes in vital signs and onset of symptoms. A pediatric cardiologist and radiologist qualitatively assessed myocardial perfusion and viability images. One child was unable to complete the stress perfusion portion of the examination, but did complete the remaining portion of the CMR. Resting heart rate was 72 ± 14 beats per minute (bpm) and rose to peak of 124 ± 17 bpm (95 ± 50% increase, P < 0.005) with regadenoson. Image quality was considered good or diagnostic in all cases. Three patients had irreversible perfusion defects. Four patients had reversible perfusion defects. Nine of the patients underwent cardiac catheterization with angiography and the findings showed excellent agreement. Regadenoson might be a safe and

  8. Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson

    Energy Technology Data Exchange (ETDEWEB)

    Noel, Cory V. [Baylor College of Medicine, Department of Pediatric Cardiology, Houston, TX (United States); Texas Children' s Hospital, Department of Pediatric Cardiology, Houston, TX (United States); Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Moffett, Brady [Texas Children' s Hospital, Department of Pharmacology, Houston, TX (United States)

    2017-03-15

    Dipyridamole and adenosine are traditional pharmacological stressors for myocardial perfusion. Regadenoson, a selective adenosine A2A agonist, has a lower side effect profile with lower incidence of bronchospasm and bradycardia. There is a growing need for myocardial perfusion assessment within pediatrics. There is no report on the utility of regadenoson as a stress agent in children. To observe the safety and feasibility of regadenoson as a pharmacologic stressor for perfusion cardiac MR in a pilot cohort of pediatric patients weighing more than 40 kg who have congenital heart disease and pediatric acquired heart disease. We reviewed our initial experience with regadenoson stress cardiac MR in 31 pediatric patients 15.8 ± 1.7 years (range 12-22 years) with congenital heart disease and acquired heart disease. Mean patient weight was 60 ± 15 kg (range of 40-93 kg). All patients underwent cardiac MR because of concern for ischemia. The cohort included a heterogeneous group of patients at a pediatric institution with potential risk for ischemia. Subjects' heart rate and blood pressure were monitored and pharmacologic stress was induced by injection of 400 mcg of regadenoson. We evaluated their hemodynamic response and adverse effects using changes in vital signs and onset of symptoms. A pediatric cardiologist and radiologist qualitatively assessed myocardial perfusion and viability images. One child was unable to complete the stress perfusion portion of the examination, but did complete the remaining portion of the CMR. Resting heart rate was 72 ± 14 beats per minute (bpm) and rose to peak of 124 ± 17 bpm (95 ± 50% increase, P < 0.005) with regadenoson. Image quality was considered good or diagnostic in all cases. Three patients had irreversible perfusion defects. Four patients had reversible perfusion defects. Nine of the patients underwent cardiac catheterization with angiography and the findings showed excellent agreement. Regadenoson might be a safe and

  9. Prevention of reperfusion lung injury by lidocaine in isolated rat lung ventilated with higher oxygen levels.

    Directory of Open Access Journals (Sweden)

    Das K

    2003-01-01

    Full Text Available BACKGROUND: Lidocaine, an antiarrhythmic drug has been shown to be effective against post-ischaemic reperfusion injury in heart. However, its effect on pulmonary reperfusion injury has not been investigated. AIMS: We investigated the effects of lidocaine on a postischaemic reperfused rat lung model. MATERIALS AND METHODS: Lungs were isolated and perfused at constant flow with Krebs-Henseilet buffer containing 4% bovine serum albumin, and ventilated with 95% oxygen mixed with 5% CO2. Lungs were subjected to ischaemia by stopping perfusion for 60 minutes followed by reperfusion for 10 minutes. Ischaemia was induced in normothermic conditions. RESULTS: Postischaemic reperfusion caused significant (p < 0.0001 higher wet-to-dry lung weight ratio, pulmonary arterial pressure and peak airway pressure compared to control lungs. Lidocaine, at a dose of 5mg/Kg b.w. was found to significantly (p < 0.0001 attenuate the increase in the wet-to-dry lung weight ratio, pulmonary arterial pressure and peak airway pressure observed in post-ischaemic lungs. CONCLUSION: Lidocaine is effective in preventing post-ischaemic reperfusion injury in isolated, perfused rat lung.

  10. Impact of CT perfusion imaging on the assessment of peripheral chronic pulmonary thromboembolism: clinical experience in 62 patients

    Energy Technology Data Exchange (ETDEWEB)

    Le Faivre, Julien; Khung, Suonita; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Duhamel, Alain [University of Lille, Department of Biostatistics, Lille (France); Lamblin, Nicolas [University of Lille, Department of Cardiology, Cardiology Hospital, Lille (France)

    2016-11-15

    To evaluate the impact of CT perfusion imaging on the detection of peripheral chronic pulmonary embolisms (CPE). 62 patients underwent a dual-energy chest CT angiographic examination with (a) reconstruction of diagnostic and perfusion images; (b) enabling depiction of vascular features of peripheral CPE on diagnostic images and perfusion defects (20 segments/patient; total: 1240 segments examined). The interpretation of diagnostic images was of two types: (a) standard (i.e., based on cross-sectional images alone) or (b) detailed (i.e., based on cross-sectional images and MIPs). The segment-based analysis showed (a) 1179 segments analyzable on both imaging modalities and 61 segments rated as nonanalyzable on perfusion images; (b) the percentage of diseased segments was increased by 7.2 % when perfusion imaging was compared to the detailed reading of diagnostic images, and by 26.6 % when compared to the standard reading of images. At a patient level, the extent of peripheral CPE was higher on perfusion imaging, with a greater impact when compared to the standard reading of diagnostic images (number of patients with a greater number of diseased segments: n = 45; 72.6 % of the study population). Perfusion imaging allows recognition of a greater extent of peripheral CPE compared to diagnostic imaging. (orig.)

  11. Quantitative arterial spin labelling perfusion measurements in rat models of renal transplantation and acute kidney injury at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Zimmer, Fabian; Schad, Lothar R.; Zoellner, Frank G. [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Klotz, Sarah; Hoeger, Simone; Yard, Benito A.; Kraemer, Bernhard K. [Heidelberg Univ., Mannheim (Germany). Dept. of Medicine V

    2017-05-01

    To employ ASL for the measurement of renal cortical perfusion in particular renal disorders typically associated with graft loss and to investigate its potential to detect and differentiate the related functional deterioration i.e., in a setting of acute kidney injury (AKI) as well as in renal grafts showing acute and chronic transplant rejection. 14 Lewis rats with unilateral ischaemic AKI and 43 Lewis rats with renal grafts showing acute or chronic rejections were used. All ASL measurements in this study were performed on a 3 T MR scanner using a FAIR True-FISP approach to assess renal blood flow (RBF). Perfusion maps were calculated and the cortical blood flow was determined using a region-of-interest based analysis. RBF of healthy and AKI kidneys as well as of both rejection models, were compared. In a subsample of 20 rats, creatinine clearance was measured and correlated with cortical perfusion. RBF differs significantly between healthy and AKI kidneys (P < 0.001) with a mean difference of 213 ± 80 ml/100 g/min. Renal grafts with chronic rejections show a significantly higher (P < 0.001) mean cortical perfusion (346 ± 112 ml/100 g/min) than grafts with acute rejection (240 ± 66 ml/100 g/min). Both transplantation models have a significantly (P < 0.001) lower perfusion than healthy kidneys. Renal creatinine clearance is significantly correlated (R = 0.85, P < 0.001) with cortical blood flow. Perfusion measurements with ASL have the potential to become a valuable diagnostic tool, regarding the detection of renal impairment and the differentiation of disorders that lead to a loss of renal function and that are typically associated with graft loss.

  12. Quantitative arterial spin labelling perfusion measurements in rat models of renal transplantation and acute kidney injury at 3 T

    International Nuclear Information System (INIS)

    Zimmer, Fabian; Schad, Lothar R.; Zoellner, Frank G.; Klotz, Sarah; Hoeger, Simone; Yard, Benito A.; Kraemer, Bernhard K.

    2017-01-01

    To employ ASL for the measurement of renal cortical perfusion in particular renal disorders typically associated with graft loss and to investigate its potential to detect and differentiate the related functional deterioration i.e., in a setting of acute kidney injury (AKI) as well as in renal grafts showing acute and chronic transplant rejection. 14 Lewis rats with unilateral ischaemic AKI and 43 Lewis rats with renal grafts showing acute or chronic rejections were used. All ASL measurements in this study were performed on a 3 T MR scanner using a FAIR True-FISP approach to assess renal blood flow (RBF). Perfusion maps were calculated and the cortical blood flow was determined using a region-of-interest based analysis. RBF of healthy and AKI kidneys as well as of both rejection models, were compared. In a subsample of 20 rats, creatinine clearance was measured and correlated with cortical perfusion. RBF differs significantly between healthy and AKI kidneys (P < 0.001) with a mean difference of 213 ± 80 ml/100 g/min. Renal grafts with chronic rejections show a significantly higher (P < 0.001) mean cortical perfusion (346 ± 112 ml/100 g/min) than grafts with acute rejection (240 ± 66 ml/100 g/min). Both transplantation models have a significantly (P < 0.001) lower perfusion than healthy kidneys. Renal creatinine clearance is significantly correlated (R = 0.85, P < 0.001) with cortical blood flow. Perfusion measurements with ASL have the potential to become a valuable diagnostic tool, regarding the detection of renal impairment and the differentiation of disorders that lead to a loss of renal function and that are typically associated with graft loss.

  13. Ventilation systems

    International Nuclear Information System (INIS)

    Gossler

    1980-01-01

    The present paper deals with - controlled area ventilation systems - ventilation systems for switchgear-building and control-room - other ventilation systems for safety equipments - service systems for ventilation systems. (orig./RW)

  14. The evaluation of dobutamine 99mTc-MIBI myocardial perfusion imaging in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    He Qing; Qu Wanying; Gong Junhui; Zhou Ying

    1996-01-01

    The method and the clinical value of dobutamine stress test as a substitute for exercise test in 99m Tc-MIBI myocardial perfusion imaging was investigated. 40 Patients were intravenously infused with dobutamine through IVAC syringe pumps by incremental doses, and 99m Tc-MIBI was injected at the peak dobutamine heart rate. The myocardial imaging was then performed. The rest myocardial imaging was done after 48 hours. 30 of the 31 patients with coronary heart disease showed reversible perfusion defects in dobutamine 99m Tc-MIBI myocardial perfusion images and 7 of the 9 patients without coronary heart disease showed normal images. The sensitivity of this test was 96.8% and the specificity 77.8%. None of the studies was discontinued due to dobutamine side effect. Dobutamine 99m Tc-MIBI myocardial perfusion imaging is a safe and sensitive method in the diagnosis of coronary heart disease

  15. Tidal ventilation distribution during pressure-controlled ventilation and pressure support ventilation in post-cardiac surgery patients.

    Science.gov (United States)

    Blankman, P; VAN DER Kreeft, S M; Gommers, D

    2014-09-01

    Inhomogeneous ventilation is an important contributor to ventilator-induced lung injury. Therefore, this study examines homogeneity of lung ventilation by means of electrical impedance tomography (EIT) measurements during pressure-controlled ventilation (PCV) and pressure support ventilation (PSV) using the same ventilation pressures. Twenty mechanically ventilated patients were studied after cardiac surgery. On arrival at the intensive care unit, ventilation distribution was measured with EIT just above the diaphragm for 15 min. After awakening, PCV was switched to PSV and EIT measurements were again recorded. Tidal impedance variation, a measure of tidal volume, increased during PSV compared with PCV, despite using the same ventilation pressures (P = 0.045). The distribution of tidal ventilation to the dependent lung region was more pronounced during PSV compared with PCV, especially during the first half of the inspiration. An even distribution of tidal ventilation between the dependent and non-dependent lung regions was seen during PCV at lower tidal volumes (tidal volumes (≥ 8 ml/kg). In addition, the distribution of tidal ventilation was predominantly distributed to the dependent lung during PSV at low tidal volumes. In post-cardiac surgery patients, PSV showed improved ventilation of the dependent lung region due to the contribution of the diaphragm activity, which is even more pronounced during lower assist levels. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  16. Impact of CT perfusion imaging on the assessment of peripheral chronic pulmonary thromboembolism: clinical experience in 62 patients.

    Science.gov (United States)

    Le Faivre, Julien; Duhamel, Alain; Khung, Suonita; Faivre, Jean-Baptiste; Lamblin, Nicolas; Remy, Jacques; Remy-Jardin, Martine

    2016-11-01

    To evaluate the impact of CT perfusion imaging on the detection of peripheral chronic pulmonary embolisms (CPE). 62 patients underwent a dual-energy chest CT angiographic examination with (a) reconstruction of diagnostic and perfusion images; (b) enabling depiction of vascular features of peripheral CPE on diagnostic images and perfusion defects (20 segments/patient; total: 1240 segments examined). The interpretation of diagnostic images was of two types: (a) standard (i.e., based on cross-sectional images alone) or (b) detailed (i.e., based on cross-sectional images and MIPs). The segment-based analysis showed (a) 1179 segments analyzable on both imaging modalities and 61 segments rated as nonanalyzable on perfusion images; (b) the percentage of diseased segments was increased by 7.2 % when perfusion imaging was compared to the detailed reading of diagnostic images, and by 26.6 % when compared to the standard reading of images. At a patient level, the extent of peripheral CPE was higher on perfusion imaging, with a greater impact when compared to the standard reading of diagnostic images (number of patients with a greater number of diseased segments: n = 45; 72.6 % of the study population). Perfusion imaging allows recognition of a greater extent of peripheral CPE compared to diagnostic imaging. • Dual-energy computed tomography generates standard diagnostic imaging and lung perfusion analysis. • Depiction of CPE on central arteries relies on standard diagnostic imaging. • Detection of peripheral CPE is improved by perfusion imaging.

  17. SU-C-BRA-06: Developing Clinical and Quantitative Guidelines for a 4DCT-Ventilation Functional Avoidance Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Vinogradskiy, Y; Waxweiler, T; Diot, Q; Kavanagh, B; Schubert, L; Miften, M [University of Colorado Denver, Aurora, CO (United States); Castillo, R [University of Texas Medical Branch of Galveston, Pearland, TX (United States); Guerrero, T; Castillo, E [Beaumont Health System, Royal Oak, MI (United States)

    2015-06-15

    Purpose: 4DCT-ventilation is an exciting new imaging modality that uses 4DCTs to calculate lung ventilation. Because 4DCTs are acquired as part of routine care, calculating 4DCT-ventilation allows for lung function evaluation without additional cost or inconvenience to the patient. Development of a clinical trial is underway at our institution to use 4DCT-ventilation for thoracic functional avoidance with the idea that preferential sparing of functional lung regions can decrease pulmonary toxicity. The purpose of our work was to develop the practical aspects of a 4DCT-ventilation functional avoidance clinical trial including: 1.assessing patient eligibility 2.developing trial inclusion criteria and 3.developing treatment planning and dose-function evaluation strategies. Methods: 96 stage III lung cancer patients from 2 institutions were retrospectively reviewed. 4DCT-ventilation maps were calculated using the patient’s 4DCTs, deformable image registrations, and a density-change-based algorithm. To assess patient eligibility and develop trial inclusion criteria we used an observer-based binary end point noting the presence or absence of a ventilation defect and developed an algorithm based on the percent ventilation in each lung third. Functional avoidance planning integrating 4DCT-ventilation was performed using rapid-arc and compared to the patient’s clinically used plan. Results: Investigator-determined clinical ventilation defects were present in 69% of patients. Our regional/lung-thirds ventilation algorithm identified that 59% of patients have lung functional profiles suitable for functional avoidance. Compared to the clinical plan, functional avoidance planning was able to reduce the mean dose to functional lung by 2 Gy while delivering comparable target coverage and cord/heart doses. Conclusions: 4DCT-ventilation functional avoidance clinical trials have great potential to reduce toxicity, and our data suggest that 59% of lung cancer patients have lung

  18. Decreased Lung Perfusion After Breast/Chest Wall Irradiation: Quantitative Results From a Prospective Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Liss, Adam L., E-mail: adamliss68@gmail.com [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Marsh, Robin B. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Kapadia, Nirav S. [Department of Radiation Oncology, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire (United States); McShan, Daniel L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Rogers, Virginia E. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Moran, Jean M.; Brock, Kristy K.; Schipper, Matt J.; Jagsi, Reshma [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Griffith, Kent A. [Biostatistics Unit, University of Michigan, Ann Arbor, Michigan (United States); Flaherty, Kevin R. [Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan (United States); Frey, Kirk A. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Pierce, Lori J. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2017-02-01

    Purpose: To quantify lung perfusion changes after breast/chest wall radiation therapy (RT) using pre- and post-RT single photon emission computed tomography/computed tomography (SPECT/CT) attenuation-corrected perfusion scans; and correlate decreased perfusion with adjuvant RT dose for breast cancer in a prospective clinical trial. Methods and Materials: As part of an institutional review board–approved trial studying the impact of RT technique on lung function in node-positive breast cancer, patients received breast/chest wall and regional nodal irradiation including superior internal mammary node RT to 50 to 52.2 Gy with a boost to the tumor bed/mastectomy scar. All patients underwent quantitative SPECT/CT lung perfusion scanning before RT and 1 year after RT. The SPECT/CT scans were co-registered, and the ratio of decreased perfusion after RT relative to the pre-RT perfusion scan was calculated to allow for direct comparison of SPECT/CT perfusion changes with delivered RT dose. The average ratio of decreased perfusion was calculated in 10-Gy dose increments from 0 to 60 Gy. Results: Fifty patients had complete lung SPECT/CT perfusion data available. No patient developed symptoms consistent with pulmonary toxicity. Nearly all patients demonstrated decreased perfusion in the left lung according to voxel-based analyses. The average ratio of lung perfusion deficits increased for each 10-Gy increment in radiation dose to the lung, with the largest changes in regions of lung that received 50 to 60 Gy (ratio 0.72 [95% confidence interval 0.64-0.79], P<.001) compared with the 0- to 10-Gy region. For each increase in 10 Gy to the left lung, the lung perfusion ratio decreased by 0.06 (P<.001). Conclusions: In the assessment of 50 patients with node-positive breast cancer treated with RT in a prospective clinical trial, decreased lung perfusion by SPECT/CT was demonstrated. Our study allowed for quantification of lung perfusion defects in a prospective cohort of

  19. Mechanical Ventilation

    Science.gov (United States)

    ... ventilation is a life support treatment. A mechanical ventilator is a machine that helps people breathe when ... to breathe enough on their own. The mechanical ventilator is also called a ventilator , respirator, or breathing ...

  20. Unilateralism in International Law

    DEFF Research Database (Denmark)

    Hartmann, Jacques

    2015-01-01

    or foreign territory. Many States, however, viewed the EU’s initiative as a unilateral act in violation of their sovereignty. The EU has since suspended the application of the ETS to foreign aircraft. Even so, this incident raises important questions concerning the legality of unilateral acts under...... Union (EU) decided to act unilaterally to reduce emission from aviation, by including aviation within its Emission Trading System (ETS). Initially, the EU set out to include in the ETS emissions from all major aircraft flying to or from European airports, even when these fly over the high seas...